WorldWideScience

Sample records for hydroxylapatite dermal fillers

  1. Radiological impact of the use of calcium hydroxylapatite dermal fillers

    International Nuclear Information System (INIS)

    Feeney, J.N.; Fox, J.J.; Akhurst, T.

    2009-01-01

    Aim: To report a case series in which the radiological features of the subcutaneous use of calcium hydroxylapatite (CaHa) dermal fillers are described for the first time. Materials and methods: Five patients with facial hyperattenuating hypermetabolic subcutaneous lesions were identified on 2- [ 18 F]-fluoro-2-deoxy-D-glucose (FDG) positron-emission tomography/computed tomography (PET/CT), who gave a history of facial injections to augment physical appearance. Correlation with additional imaging studies was performed. Results: All cases had subcutaneous high attenuation material on CT (range 280-700 HU), which was FDG avid on PET, with a standardized uptake value (SUV) range of 2.9-13.4. Magnetic resonance imaging (MRI) demonstrated a heterogeneous intermediate signal intensity subcutaneous lesion with enhancement post-gadolinium in one case. Conclusions: CaHa dermal filler is hyperattenuating on CT, hypermetabolic on FDG-PET imaging, of intermediate signal intensity on MRI, and is a potential cause of a false-positive imaging study.

  2. Volume correction in the aging hand: role of dermal fillers

    Directory of Open Access Journals (Sweden)

    Rivkin AZ

    2016-08-01

    Full Text Available Alexander Z Rivkin David Geffen/UCLA School of Medicine Los Angeles, CA, USA Abstract: The hands, just like the face, are highly visible parts of the body. They age at a similar rate and demonstrate comparable changes with time, sun damage, and smoking. Loss of volume in the hands exposes underlying tendons, veins, and bony prominences. Rejuvenation of the hands with dermal fillers is a procedure with high patient satisfaction and relatively low risk for complications. This study will review relevant anatomy, injection technique, clinical safety, and efficacy of dermal filler volumization of the aging hand. Keywords: dermal fillers, hands, volumization, hyaluronic acid, calcium hydroxylapatite

  3. Update on botulinum toxin and dermal fillers.

    Science.gov (United States)

    Berbos, Zachary J; Lipham, William J

    2010-09-01

    The art and science of facial rejuvenation is an ever-evolving field of medicine, as evidenced by the continual development of new surgical and nonsurgical treatment modalities. Over the past 10 years, the use of botulinum toxin and dermal fillers for aesthetic purposes has risen sharply. Herein, we discuss properties of several commonly used injectable products and provide basic instruction for their use toward the goal of achieving facial rejuvenation. The demand for nonsurgical injection-based facial rejuvenation products has risen enormously in recent years. Used independently or concurrently, botulinum toxin and dermal filler agents offer an affordable, minimally invasive approach to facial rejuvenation. Botulinum toxin and dermal fillers can be used to diminish facial rhytides, restore facial volume, and sculpt facial contours, thereby achieving an aesthetically pleasing, youthful facial appearance.

  4. Dermal fillers for facial soft tissue augmentation.

    Science.gov (United States)

    Dastoor, Sarosh F; Misch, Carl E; Wang, Hom-Lay

    2007-01-01

    Nowadays, patients are demanding not only enhancement to their dental (micro) esthetics, but also their overall facial (macro) esthetics. Soft tissue augmentation via dermal filling agents may be used to correct facial defects such as wrinkles caused by age, gravity, and trauma; thin lips; asymmetrical facial appearances; buccal fold depressions; and others. This article will review the pathogenesis of facial wrinkles, history, techniques, materials, complications, and clinical controversies regarding dermal fillers for soft tissue augmentation.

  5. Consensus Recommendations for Optimal Augmentation of the Asian Face with Hyaluronic Acid and Calcium Hydroxylapatite Fillers.

    Science.gov (United States)

    Rho, Nark-Kyoung; Chang, Yao-Yuan; Chao, Yates Yen-Yu; Furuyama, Nobutaka; Huang, Peter Y C; Kerscher, Martina; Kim, Hee-Jin; Park, Je-Young; Peng, Hsien Li Peter; Rummaneethorn, Paisal; Rzany, Berthold; Sundaram, Hema; Wong, Chin Ho; Yang, Yuli; Prasetyo, Adri Dwi

    2015-11-01

    Although the use of filling agents for soft-tissue augmentation has increased worldwide, most consensus statements do not distinguish between ethnic populations. There are, however, significant differences between Caucasian and Asian faces, reflecting not only cultural disparities, but also distinctive treatment goals. Unlike aesthetic patients in the West, who usually seek to improve the signs of aging, Asian patients are younger and request a broader range of indications. Members of the Asia-Pacific Consensus group-comprising specialists from the fields of dermatology, plastic surgery, anatomy, and clinical epidemiology-convened to develop consensus recommendations for Asians based on their own experience using cohesive polydensified matrix, hyaluronic acid, and calcium hydroxylapatite fillers. The Asian face demonstrates differences in facial structure and cosmetic ideals. Improving the forward projection of the "T zone" (i.e., forehead, nose, cheeks, and chin) forms the basis of a safe and effective panfacial approach to the Asian face. Successful augmentation may be achieved with both (1) high- and low-viscosity cohesive polydensified matrix/hyaluronic acid and (2) calcium hydroxylapatite for most indications, although some constraints apply. The Asia-Pacific Consensus recommendations are the first developed specifically for the use of fillers in Asian populations. Therapeutic, V.

  6. Complications caused by injection of dermal filler in Danish patients

    DEFF Research Database (Denmark)

    Uth, Charlotte Caspara; Elberg, Jens Jørgen; Zachariae, Claus

    2016-01-01

    Background: The usage of dermal fillers has increased significantly in recent years. Soft tissue augmentation with fillers helps to diminish the facial lines and to restore volume and fullness in the face at a relatively low cost. With the increasing number of treatments, the number of complicati......Background: The usage of dermal fillers has increased significantly in recent years. Soft tissue augmentation with fillers helps to diminish the facial lines and to restore volume and fullness in the face at a relatively low cost. With the increasing number of treatments, the number...

  7. Chitosan solutions as injectable systems for dermal filler applications: Rheological characterization and biological evidence.

    Science.gov (United States)

    Halimi, C; Montembault, A; Guerry, A; Delair, T; Viguier, E; Fulchiron, R; David, L

    2015-01-01

    A new generation of dermal filler for wrinkle filler based on chitosan was compared to current hyaluronic acid-based dermal fillers by using a new rheological performance criterion based on viscosity during injection related to Newtonian viscosity. In addition an in vivo evaluation was performed for preclinical evidence of chitosan use as dermal filler. In this way, biocompatibility and dermis reconstruction was evaluated on a pig model.

  8. The basic science of dermal fillers: past and present Part II: adverse effects.

    Science.gov (United States)

    Gilbert, Erin; Hui, Andrea; Meehan, Shane; Waldorf, Heidi A

    2012-09-01

    The ideal dermal filler should offer long-lasting aesthetic improvement with a minimal side-effect profile. It should be biocompatible and stable within the injection site, with the risk of only transient undesirable effects from injection alone. However, all dermal fillers can induce serious and potentially long-lasting adverse effects. In Part II of this paper, we review the most common adverse effects related to dermal filler use.

  9. Soft tissue augmentation - Use of hyaluronic acid as dermal filler

    Directory of Open Access Journals (Sweden)

    Vedamurthy Maya

    2004-11-01

    Full Text Available Soft tissue augmentation has revolutionized the treatment of the aging face. It is a technique in which a substance is injected under the skin. The concept of utilizing materials for soft tissue augmentation actually began around 1950 with the use of fluid silicone. Today we have a large armamentarium of implant materials to delay the tell tale signs of aging. Filling has replaced conventional surgery in facial rejuvenation. In this article, the emphasis will be on hyaluronic acid as this substance is easily available in India and ranks among the most widely used dermal fillers.

  10. Soft tissue augmentation - Use of hyaluronic acid as dermal filler

    Directory of Open Access Journals (Sweden)

    Vedamurthy Maya

    2004-01-01

    Full Text Available Soft tissue augmentation has revolutionized the treatment of the aging face. It is a technique in which a substance is injected under the skin. The concept of utilizing materials for soft tissue augmentation actually began around 1950 with the use of fluid silicone. Today we have a large armamentarium of implant materials to delay the tell tale signs of aging. Filling has replaced conventional surgery in facial rejuvenation. In this article, the emphasis will be on hyaluronic acid as this substance is easily available in India and ranks among the most widely used dermal fillers.

  11. The basic science of dermal fillers: past and present Part I: background and mechanisms of action.

    Science.gov (United States)

    Gilbert, Erin; Hui, Andrea; Waldorf, Heidi A

    2012-09-01

    Dermal fillers have provided a safe and effective means for aesthetic soft tissue augmentation, and have experienced a dramatic increase in popularity during the past 10 years. Much focus has been placed upon filler technique and patient outcomes. However, there is a relative lack of literature reviewing the basic science of dermal fillers, which is vital to a physician's understanding of how each product behaves in vivo. Part I of this article reviews the basic science and evolution of both historical and contemporary dermal fillers; Part II examines their adverse effects. We endeavor to provide the physician with a practical approach to choosing products that maximize both aesthetic outcome and safety.

  12. Comparison of the rheological properties of viscosity and elasticity in two categories of soft tissue fillers: calcium hydroxylapatite and hyaluronic acid.

    Science.gov (United States)

    Sundaram, Hema; Voigts, Bob; Beer, Kenneth; Meland, Melissa

    2010-11-01

    Two types of soft tissue filler that are in common use are those formulated primarily with calcium hydroxylapatite (CaHA) and those with cross-linked hyaluronic acid (cross-linked HA). To provide physicians with a scientific rationale for determining which soft tissue fillers are most appropriate for volume replacement. Six cross-linked HA soft tissue fillers (Restylane and Perlane from Medicis, Scottsdale, AZ; Restylane SubQ from Q-Med, Uppsala, Sweden; and Juvéderm Ultra, Juvéderm Ultra Plus, and Juvéderm Voluma from Allergan, Pringy, France) and a soft tissue filler consisting of CaHA microspheres in a carrier gel containing carboxymethyl cellulose (Radiesse, BioForm Medical, Inc., San Mateo, CA). METHODS The viscosity and elasticity of each filler gel were quantified according to deformation oscillation measurements conducted using a Thermo Haake RS600 Rheometer (Newington, NH) using a plate and plate geometry with a 1.2-mm gap. All measurements were performed using a 35-mm titanium sensor at 30°C. Oscillation measurements were taken at 5 pascal tau (τ) over a frequency range of 0.1 to 10 Hz (interpolated at 0.7 Hz). Researchers chose the 0.7-Hz frequency because it elicited the most reproducible results and was considered physiologically relevant for stresses that are common to the skin. RESULTS The rheological measurements in this study support the concept that soft tissue fillers that are currently used can be divided into three groups. CONCLUSION Rheological evaluation enables the clinician to objectively classify soft tissue fillers, to select specific filler products based on scientific principles, and to reliably predict how these products will perform--lifting, supporting, and sculpting--after they are appropriately injected. © 2010 by the American Society for Dermatologic Surgery, Inc.

  13. Examining the Efficacy of Calcium Hydroxylapatite Filler With Integral Lidocaine in Correcting Volume Loss of the Jawline-A Pilot Study.

    Science.gov (United States)

    Juhász, Margit L W; Marmur, Ellen S

    2018-04-19

    Patients seek 3-dimensional volume restoration of the jawline to obtain a "defined" line. Injection of filler into the jawline is not approved by the Food and Drug Administration; however, dermatologists have injected this area with positive results, minimal adverse events, and high patient satisfaction. This study explores the efficacy of premixed calcium hydroxylapatite filler with integral lidocaine [CaHA(+)] to correct volume defects of the jawline. It examines the longevity, safety, and patient satisfaction (up to 12 months) of CaHA(+) for jawline volume loss correction. This is a single-investigator, nonblinded study. Twenty subjects received CaHA(+) filler injection in the jawline, with follow-up evaluations conducted at 14 days, 6 weeks, and 3, 6, 9, and 12 months. CaHA(+) injection in the jawline results in statistically significant restoration in volume and improvement in appearance lasting up to 12 months. Overall, subjects report "moderate" improvement on the Global Aesthetic Improvement Scale. It is important for cosmetic surgeons and dermatologists to have access to data on the efficacy and safety of injectables. The data obtained in this study show that CaHA(+) is an effective and safe option to correct jawline volume loss and is associated with high patient satisfaction.

  14. Dermal fillers in aesthetics: an overview of adverse events and treatment approaches.

    Science.gov (United States)

    Funt, David; Pavicic, Tatjana

    2015-01-01

    The ever-expanding range of dermal filler products for aesthetic soft tissue augmentation is of benefit for patients and physicians, but as indications and the number of procedures performed increase, the number of complications will likely also increase. To describe potential adverse events associated with dermal fillers and to provide structured and clear guidance on their treatment and avoidance. Reports of dermal filler complications in the medical literature were reviewed and, based on the publications retrieved and the authors' extensive experience, recommendations for avoiding and managing complications are provided. Different dermal fillers have widely varying properties, associated risks, and injection requirements. All dermal fillers have the potential to cause complications. Most are related to volume and technique, though some are associated with the material itself. The majority of adverse reactions are mild and transient, such as bruising and trauma-related edema. Serious adverse events are rare, and most are avoidable with proper planning and technique. For optimum outcomes, aesthetic physicians should have a detailed understanding of facial anatomy; the individual characteristics of available fillers; their indications, contraindications, benefits, and drawbacks; and ways to prevent and avoid potential complications.

  15. Wrinkle Fillers

    Science.gov (United States)

    ... your health care provider about their training and experience injecting dermal fillers in the face. Do not inject yourself with dermal fillers. Do not purchase dermal filler products online, because they could be ...

  16. Standard guidelines for the use of dermal fillers

    Directory of Open Access Journals (Sweden)

    Vedamurthy Maya

    2008-03-01

    Full Text Available Currently used fillers vary greatly in their sources, efficacy duration and site of deposition; detailed knowledge of these properties is essential for administering them. Indications for fillers include facial lines (wrinkles, folds, lip enhancement, facial deformities, depressed scars, periocular melanoses, sunken eyes, dermatological diseases-angular cheilitis, scleroderma, AIDS lipoatrophy, earlobe plumping, earring ptosis, hand, neck, dιcolletι rejuvenation. Physicians′ qualifications : Any qualified dermatologist may use fillers after receiving adequate training in the field. This may be obtained either during postgraduation or at any workshop dedicated to the subject of fillers. The physicians should have a thorough knowledge of the anatomy of the area designated to receive an injection of fillers and the aesthetic principles involved. They should also have a thorough knowledge of the chemical nature of the material of the filler, its longevity, injection techniques, and any possible side effects. Facility: Fillers can be administered in the dermatologist′s minor procedure room. Preoperative counseling and informed consent: Detailed counseling with respect to the treatment, desired effects, and longevity of the filler should be discussed with the patient. Patients should be given brochures to study and adequate opportunity to seek information. Detailed consent forms need to be completed by the patients. A consent form should include the type of filler, longevity expected and possible postoperative complications. Preoperative photography should be carried out. Choice of the filler depends on the site, type of defect, results needed, and the physician′s experience. Injection technique and volume depend on the filler and the physician′s preference, as outlined in these guidelines.

  17. Hydroxylapatite chromatography.

    Science.gov (United States)

    Broadhurst, A V

    2001-05-01

    Hydroxylapatite (also called hydroxyapatite), a form of calcium phosphate, can be used as a matrix for the chromatography of both proteins and nucleic acids. Protocols are provided for both standard low-pressure chromatography of a protein mixture using a hydroxylapatite column prepared in the laboratory, and an HPLC method, applicable to proteins and nucleic acids, that uses a commercially available column. Alternate protocols describe column chromatography using a step gradient or batch binding and step-gradient elution.

  18. Microvascular complications associated with injection of cosmetic facelift dermal fillers

    Science.gov (United States)

    Yousefi, Siavash; Prendes, Mark; Chang, Shu-Hong; Wang, Ruikang K.

    2015-02-01

    Minimally-invasive cosmetic surgeries such as injection of subdermal fillers have become very popular in the past decade. Although rare, some complications may follow injections such as tissue necrosis and even blindness. There exist two hypothesis regarding source of these complications both of which include microvasculature. The first hypothesis is that fillers in between the tissue structures and compress microvasculature that causes blockage of tissue neutrition and oxygen exchange in the tissue. In another theory, it is hypothesized that fillers move inside major arteries and block the arteries/veins. In this paper, we study these hypotheses using optical coherence tomography and optical microangiography technologies with different hyaluronic-acid fillers in a mouse ear model. Based on our observations, the fillers eventually block arteries/veins if injected directly into them that eventually causes tissue necrosis.

  19. Late-Onset Inflammatory Response to Hyaluronic Acid Dermal Fillers

    Directory of Open Access Journals (Sweden)

    Tahera Bhojani-Lynch, MRCOphth, CertLRS, MBCAM, DipCS

    2017-12-01

    Conclusion:. Late-onset inflammatory reactions to HA fillers may be self-limiting but are easily and rapidly treatable with oral steroids, and with hyaluronidase in the case of lumps. It is likely these reactions are due to a Type IV delayed hypersensitivity response. Delayed inflammation associated with HA fillers is nonbrand specific. However, the case where 2 different brands were injected during the same session, but only 1 brand triggered a hypersensitivity reaction, suggests that the technology used in the manufacturing process, and the subsequent differing products of degradation, may have an influence on potential allergic reactions to HA fillers.

  20. A case of cellulitis-like foreign body reaction after hyaluronic acid dermal filler injection

    Directory of Open Access Journals (Sweden)

    Yo Sup Shin

    2018-03-01

    Full Text Available A 58-year-old female presented with 3 weeks history of painful skin lesion on the right cheek. Diagnosis was cellulitis based on the clinical manifestation and laboratory test. However, skin lesion did not improve with antibiotics, and as a consequence, biopsy was performed. Based on histopathological findings and additional information of her previous history of intradermal filler injection, the lesion was diagnosed to be foreign body reaction. Previous reported cases of foreign body reaction induced by hyaluronic acid dermal filler typically manifested as nodular lesions, but cellulitis-like cutaneous manifestation has not been reported. Therefore, we report this interesting case of foreign body reaction after hyaluronic acid dermal filler injection.

  1. Foreign Body Granulomas after the Use of Dermal Fillers: Pathophysiology, Clinical Appearance, Histologic Features, and Treatment

    Directory of Open Access Journals (Sweden)

    Jeong Min Lee

    2015-03-01

    Full Text Available A foreign body granuloma is a non-allergic chronic inflammatory reaction that is mainly composed of multinucleated giant cells. Foreign body granulomas may occur after the administration of any dermal filler. Factors such as the volume of the injection, impurities present in the fillers, and the physical properties of fillers affect granuloma formation. The formation of granulomas involves five phases: protein adsorption, macrophage adhesion, macrophage fusion, and crosstalk. The clinical and pathologic features of granulomas vary depending on the type of filler that causes them. Foreign body granulomas can be treated effectively with intralesional corticosteroid injections. Surgical excisions of granulomas tend to be incomplete because granulomas have ill-defined borders and moreover, surgical excisions may leave scars and deformities.

  2. Lip Injection Techniques Using Small-Particle Hyaluronic Acid Dermal Filler.

    Science.gov (United States)

    Chiu, Annie; Fabi, Sabrina; Dayan, Steven; Nogueira, Alessandra

    2016-09-01

    The shape and fullness of the lips have a significant role in facial aesthetics and outward appearance. The corrective needs of a patient can range from a subtle enhancement to a complete recontouring including correction of perioral rhytides. A comprehensive understanding of the lower face anatomical features and injection site techniques are foundational information for injectors. Likewise, the choice of filler material contributes to the success of the injection techniques used, and facilitates a safe, effective, and natural appearing outcome. The small-particle HA 20 mg/mL with lidocaine 0.3% (SP-HAL, Restylane® Silk; Galderma Laboratories, Fort Worth, Texas) is indicated for submucosal implantation for lip augmentation and dermal implantation for correction of perioral rhytides. Due to its rheological properties and smaller particle size, SP-HAL is a well-suited filler for the enhancement and correction of lip shape and volume, as well as for the correction of very fine perioral rhytides. This work is a combined overview of techniques found in the current literature and recommendations provided by contributing authors. J Drugs Dermatol. 2016;15(9):1076-1082.

  3. Composite synthetic hydroxyapatite 30%, in two physical states, as dermal filler

    Directory of Open Access Journals (Sweden)

    Rodrigo Viana Sepúlveda

    2013-08-01

    Full Text Available The aim of this study was to evaluate the response to the implantation of synthetic hydroxyapatite 30% (HAP-91® in different physical states as dermal filler. Eighteen New Zealand rabbits were used, distributed randomly into two equal groups and then divided into three groups according to the postoperative period at 8, 21 and 49 days. One mL of HAP-91®, fluid and viscous, was implanted in the subcutaneous tissue, 1 cm proximal to the cranial crest of the right scapula. The thickness of the skin was measured before and after implantation and for the following 15 days. Pain sensitivity assessment was conducted, assigning the following scores: 0 - when the animal allowed the touch of the implant area and expressed no signs of pain; 1 - when the animal allowed the touch, but pain reaction occurred, like increase of the respiratory rate or attempt to escape; 2 - when the animal did not allow the touch to the implanted area. At 8, 21 and 49 days, biopsy of the implanted area was performed. No difference was observed between the thickness of the skin (p>0.05 and all animals received a score 0 for soreness. Histological analysis did not reveal any obvious inflammatory process, showing a predominance of mononuclear cells in samples of eight days and tissue organization around the biomaterial with a tendency to encapsulation. The results indicate that HAP-91®, both viscous and fluid, is biocompatible and suitable for dermal filling.

  4. Preventing the Complications Associated with the Use of Dermal Fillers in Facial Aesthetic Procedures: An Expert Group Consensus Report.

    Science.gov (United States)

    Urdiales-Gálvez, Fernando; Delgado, Nuria Escoda; Figueiredo, Vitor; Lajo-Plaza, José V; Mira, Mar; Ortíz-Martí, Francisco; Del Rio-Reyes, Rosa; Romero-Álvarez, Nazaret; Del Cueto, Sofía Ruiz; Segurado, María A; Rebenaque, Cristina Villanueva

    2017-06-01

    The use of dermal fillers in minimally invasive facial aesthetic procedures has become increasingly popular of late, yet as the indications and the number of procedures performed increase, the number of complications is also likely to increase. Paying special attention to specific patient characteristics and to the technique used can do much to avoid these complications. Indeed, a well-trained physician can also minimize the impact of such problems when they do occur. A multidisciplinary group of experts in aesthetic treatments reviewed the main factors associated with the complications that arise when using dermal fillers. A search of English, French and Spanish language articles in PubMed was performed using the terms "complications" OR "soft filler complications" OR "injectable complications" AND "dermal fillers". An initial document was drafted that reflected the complications identified and recommendations as to how they should be handled. This document was then reviewed and modified by the expert panel, until a final text was agreed upon and validated. The panel addressed consensus recommendations about the preparation, the procedure and the post-procedural care. The panel considered it crucial to obtain an accurate medical history to prevent potential complications. An additional clinical assessment, including standardized photography, is also crucial to evaluate the outcomes and prevent potential complications. Furthermore, the state of the operating theatre, the patient's health status and the preparation of the skin are critical to prevent superficial soft tissue infections. Finally, selecting the appropriate technique, based on the physician's experience, as well as the characteristics of the patient and filler, helps to ensure successful outcomes and limits the complications. This consensus document provides key elements to help clinicians who are starting to use dermal fillers to employ standard procedures and to understand how best to prevent

  5. Applications and Emerging Trends of Hyaluronic Acid in Tissue Engineering, as a Dermal Filler, and in Osteoarthritis Treatment

    Science.gov (United States)

    Fakhari, Amir; Berkland, Cory

    2013-01-01

    Hyaluronic acid (HA) is a naturally occurring biodegradable polymer with a variety of applications in medicine including scaffolding for tissue engineering, dermatological fillers, and viscosupplementation for osteoarthritis treatment. HA is available in most connective tissues in body fluids such as synovial fluid and the vitreous humor of the eye. HA is responsible for several structural properties of tissues as a component of extracellular matrix (ECM) and is involved in cellular signaling. Degradation of HA is a step-wise process that can occur via enzymatic or non-enzymatic reactions. A reduction in HA mass or molecular weight via degradation or slowing of synthesis affects physical and chemical properties such as tissue volume, viscosity, and elasticity. This review addresses the distribution, turnover, and tissue-specific properties of HA. This information is used as context for considering recent products and strategies for modifying the viscoelastic properties of HA in tissue engineering, as a dermal filler, and in osteoarthritis treatment. PMID:23507088

  6. Calcium hydroxylapatite for jawline rejuvenation: consensus recommendations.

    Science.gov (United States)

    Dallara, Jean-Marie; Baspeyras, Martine; Bui, Patrick; Cartier, Hugues; Charavel, Marie-Hélène; Dumas, Laurent

    2014-03-01

    Age-associated volume loss is now known to play an important role in the structural changes of the aging face. In the lower face, this manifests as drooping of the corners of the mouth and jowl leading to a loss of the oval jawline of youth. Jawline reshaping by replacing volume has therefore become an indispensable component of modern facial rejuvenation. Calcium hydroxylapatite (CaHA; Radiesse® , Merz Pharmaceuticals GmbH, Frankfurt, Germany) is an injectable filler with a cosmetic indication for tissue augmentation. The ability of calcium hydroxylapatite to provide immediate and long-lasting volume enhancement makes it an ideal agent for restoring an oval jawline. This consensus statement has been developed to assist clinicians who would like to gain more experience in the use of volumizing agents to achieve an optimal outcome with this procedure. Using the recently developed Merz Aesthetics Scale® for jawline, the consensus provides a treatment protocol for individuals at each stage of oval loss and presents a series of before and after images to illustrate the improvements that can be achieved. Specific recommendations for calcium hydroxylapatite including type of anesthesia, injection techniques, volume for injection, use in combination with other procedures, and expected duration of corrections are provided. Techniques for minimizing and managing expected problems and potential complications are also described. Calcium hydroxylapatite is appropriate for treating patients at any stage of oval loss. © 2014 Wiley Periodicals, Inc.

  7. Effect of monopolar radiofrequency treatment over soft-tissue fillers in an animal model: part 2.

    Science.gov (United States)

    Shumaker, Peter R; England, Laura J; Dover, Jeffrey S; Ross, E Victor; Harford, Robert; Derienzo, Damian; Bogle, Melissa; Uebelhoer, Nathan; Jacoby, Mark; Pope, Karl

    2006-03-01

    Monopolar radiofrequency (RF) treatment is used by physicians to heat skin and promote tissue tightening and contouring. Cosmetic fillers are used to soften deep facial lines and wrinkles. Patients who have had dermal fillers implanted may also benefit from or are candidates for monopolar RF skin tightening. This study examined the effect of RF treatment on various dermal filler substances. This is the second part of a two-part study. A juvenile farm pig was injected with dermal fillers including cross-linked human collagen (Cosmoplast), polylactic acid (PLA) (Sculptra), liquid injectable silicone (Silikon 1000), calcium hydroxylapatite (CaHA) (Radiesse), and hyaluronic acid (Restylane). Skin injected with dermal fillers was RF-treated using a 1.5-cm2 treatment tip and treatment levels typically used in the clinical setting. Fillers were examined histologically 5 days, 2 weeks, or 1 month after treatment. Histological specimens were scored for inflammatory response, foreign body response, and fibrosis in order to assess the effect of treatment on early filler processes, such as inflammation and encapsulation. Each filler substance produced a characteristic inflammatory response. No immediate thermal effect of RF treatment was observed histologically. RF treatment resulted in statistically significant increases in the inflammatory, foreign body, and fibrotic responses associated with the filler substances. Monopolar RF treatment levels that are typically used in the clinical setting were employed in this animal study. RF treatment resulted in measurable and statistically significant histological changes associated with the various filler materials. Additional clinical and histological studies are required to determine the optimal timing of monopolar RF treatment and filler placement for maximal potential aesthetic outcome. 2006 Wiley-Liss, Inc.

  8. A five-patient satisfaction pilot study of calcium hydroxylapatite injection for treatment of aging hands.

    Science.gov (United States)

    Marmur, Ellen S; Al Quran, Hanadi; De Sa Earp, Ana Paula; Yoo, Jane Y

    2009-12-01

    The process of skin aging is not limited to the face but involves every part of the body, including the hands. A common manifestation of aging of the hands is the loss of volume, which occurs as the skin loses its subcutaneous fat. Injectable dermal fillers have surfaced as a popular method to address such deficiencies. To report the use of calcium hydroxylapatite (CaHA) to address lost volume. Five female subjects with soft tissue deficiency of the dorsa of the hands were enrolled at Mount Sinai Medical Center. A solution of CaHA with 2% lidocaine in amounts of 0.3 to 1.0 mL was injected interdigitally at each of three to five insertion sites; the sites were massaged and molded up to three times to ensure an optimal cosmetic end point. Subjects were seen for a follow-up visit after 1, 4, 16, and 24 weeks. With a single injection, all subjects reached their correction goals without requiring any touch-ups. At the 24-week visit, the subjects retained the filling effect, with no adverse events and high patient satisfaction. CaHA, a new, easily injectable, safe dermal filler, has emerged as an excellent option for soft tissue augmentation in aging hands.

  9. Comparing Efficacy and Costs of Four Facial Fillers in Human Immunodeficiency Virus-Associated Lipodystrophy: A Clinical Trial.

    Science.gov (United States)

    Vallejo, Alfonso; Garcia-Ruano, Angela A; Pinilla, Carmen; Castellano, Michele; Deleyto, Esther; Perez-Cano, Rosa

    2018-03-01

    The objective of this study was to evaluate and compare the safety and effectiveness of four different dermal fillers in the treatment of facial lipoatrophy secondary to human immunodeficiency virus. The authors conducted a clinical trial including 147 patients suffering from human immunodeficiency virus-induced lipoatrophy treated with Sculptra (poly-L-lactic acid), Radiesse (calcium hydroxylapatite), Aquamid (polyacrylamide), or autologous fat. Objective and subjective changes were evaluated during a 24-month follow-up. Number of sessions, total volume injected, and overall costs of treatment were also analyzed. A comparative cost-effectiveness analysis of the treatment options was performed. Objective improvement in facial lipoatrophy, assessed by the surgeon in terms of changes from baseline using the published classification of Fontdevila, was reported in 53 percent of the cases. Patient self-evaluation showed a general improvement after the use of facial fillers. Patients reported being satisfied with the treatment and with the reduced impact of lipodystrophy on their quality of life. Despite the nonsignificant differences observed in the number of sessions and volume, autologous fat showed significantly lower costs than all synthetic fillers (p < 0.05). Surgical treatment of human immunodeficiency virus-associated facial lipoatrophy using dermal fillers is a safe and effective procedure that improves the aesthetic appearance and the quality of life of patients. Permanent fillers and autologous fat achieve the most consistent results over time, with lipofilling being the most cost-effective procedure.

  10. “Home of Younger Skin” (HOYS program: Defining the change in apparent skin age after facial treatment with botulinum toxin and dermal fillers

    Directory of Open Access Journals (Sweden)

    Goodman GJ

    2012-08-01

    Full Text Available Greg J Goodman, Stefania RobertsSouth Yarra, Melbourne, Victoria, AustraliaBackground: Objective and subjective scales estimating improvement in both clinical studies and clinical practice are becoming more mainstream. However, the use of a system to analyze improvement in aging with a multiplicity of treatments would be useful. The purpose of this study was to use a recently developed educative and patient self-assessment program (“Home of Younger Skin”, HOYS for assessment of the effect of facial treatment with neurotoxins and filling agents in terms of decreasing apparent age.Methods: Four patients underwent facial treatments with neurotoxins and dermal fillers by an experienced blinded physician and were assessed twice utilizing an age analysis program (HOYS, once before and then 6 weeks after completion of treatment.Results: The four patients showed an average reduction in apparent facial age of 7.5 years. The individual “regions” differed in their reductions. The upper face showed a decline of 13.5 years, the periorbital region 9.25 years, the mid face 4.5 years, and the lower face 12.25 years.Conclusion: Use of this previously validated self-assessment program may prove to be a useful measure of patient-reported improvement with treatment.Keywords: HOYS, rejuvenation, botulinum toxin, fillers, laser, aging

  11. [Body experience and self-esteem after minimally invasive skin rejuvenation : Study of female patients using botulinum toxin A and/or dermal fillers].

    Science.gov (United States)

    Scharschmidt, D; Preiß, S; Brähler, E; Fischer, T; Borkenhagen, A

    2017-12-01

    More and more people worldwide and also in Germany are using botulinum toxin type A (BoNT-A) and hyaluronic acid injections for skin rejuvenation. Study on body image and self-esteem of women with BoNT-A and/or hyaluronic acid filler treatment. A total of 145 women who requested BoNT-A and/or hyaluronic acid injections completed a survey comprised of the body dysmorphic disorder questionnaire, the Rosenberg self-esteem scale and questionnaires on the attitudes and motives on measures for optimization of the body and demographic features. Using this instrument data on the body image and self-esteem as well as attitudes and motives for utilization of minimally invasive skin rejuvenation were collated. Female users of minimally invasive skin rejuvenation showed an overall higher socioeconomic status and an above average high monthly income. They lived in a partnership more often in comparison to women of equal age living in Berlin. The users of BoNT-A and/or hyaluronic acid fillers showed no conspicuous differences in body image and self-esteem. They showed a moderately positive attitude to body optimization procedures and 91% achieved their standard weight with a body mass index (BMI) of ≤25 kg/m 2 in comparison to 56% of German women in the same age range (25 to ≥75 years old). In the first study of body image and self-esteem in users of BoNT‑A and/or dermal fillers in German women, the users showed no signs of body dysmorphic patterns or disorders of self-esteem.

  12. An Open-Label Uncontrolled, Multicenter Study for the Evaluation of the Efficacy and Safety of the Dermal Filler Princess VOLUME in the Treatment of Nasolabial Folds

    Directory of Open Access Journals (Sweden)

    Daisy Kopera

    2015-01-01

    Full Text Available The dermal filler Princess VOLUME is a highly cross-linked, viscoelastic hyaluronic acid injectable gel implant used for aesthetic treatment. To evaluate the efficacy and safety of Princess VOLUME in the treatment of nasolabial folds, an open-label uncontrolled, multicenter study was conducted. Forty-eight subjects were recruited who had moderate to deep wrinkles, according to the Modified Fitzpatrick Wrinkle Scale (MFWS. Subjects received Princess VOLUME in both nasolabial folds at Day 0. Nasolabial fold severity was evaluated at 30, 90, 180, and 270 days after treatment, using the MFWS and the Global Aesthetic Improvement Scale (GAIS. Adverse events and treatment site reactions were recorded. Among the 48 subjects, 93.8% were female with a median age of 52 years. There were significant improvements (P<0.0001 in the MFWS scores at 30, 180, and 270 days after treatment compared with those at baseline, with a mean decrease of 1.484 (±0.408, 1.309 (±0.373, and 1.223 (±0.401, respectively; hence the primary endpoint was achieved and clinical efficacy demonstrated. Princess VOLUME was well tolerated, and most adverse events were injection site reactions of mild to moderate severity. Subject satisfaction (97.9%, subject recommendation of the treatment (93.6%, and investigators GAIS scores (97.9% improvement were high.

  13. "Home of Younger Skin" (HOYS) program: Defining the change in apparent skin age after facial treatment with botulinum toxin and dermal fillers.

    Science.gov (United States)

    Goodman, Greg J; Roberts, Stefania

    2012-01-01

    Objective and subjective scales estimating improvement in both clinical studies and clinical practice are becoming more mainstream. However, the use of a system to analyze improvement in aging with a multiplicity of treatments would be useful. The purpose of this study was to use a recently developed educative and patient self-assessment program ("Home of Younger Skin", HOYS) for assessment of the effect of facial treatment with neurotoxins and filling agents in terms of decreasing apparent age. Four patients underwent facial treatments with neurotoxins and dermal fillers by an experienced blinded physician and were assessed twice utilizing an age analysis program (HOYS), once before and then 6 weeks after completion of treatment. The four patients showed an average reduction in apparent facial age of 7.5 years. The individual "regions" differed in their reductions. The upper face showed a decline of 13.5 years, the periorbital region 9.25 years, the mid face 4.5 years, and the lower face 12.25 years. Use of this previously validated self-assessment program may prove to be a useful measure of patient-reported improvement with treatment.

  14. Clinical and instrumental evaluation of a cross-linked hyaluronic acid filler dermal injection: effects on nasolabial folds skin biophysical parameters and augmentation from a single-dose, monocentric, open-label trial.

    Science.gov (United States)

    Cameli, Norma; Mariano, Maria; Serio, Mirko; Berardesca, Enzo

    2016-10-01

    When a hyaluronic acid dermal device to fill soft tissues is chosen, efficacy, safety and durability are key concerns. This is an open-label prospective study to instrumentally evaluate the effects of HA filler dermal injection on nasolabial folds skin biophysical parameters and augmentation. A single Italian site treated female subjects aged 40-55, for nasolabial folds, with a single standardized injection. The outcome was evaluated with objective quantitative measurements after 90 (T1) and 180 days (T2) from the injection comparing to baseline (T0) by means of Corneometer (skin hydration measurement), Cutometer (skin elasticity measurement), and Visioface devices for digital and UV computerized image analysis. Secondary endpoints were safety assessment, subject investigator satisfaction with the intervention. Assessment of aesthetic results included photographic documentation. The computerized image analysis confirmed the clinical assessment showing statistically significant reduction in nasolabial folds both at T1 and T2. Visioface® indexes showed a marked and statistical significant response. An excellent profile of satisfaction of the product at T2 from investigators and patients was recorded. Skin hydration and elasticity did not show significant changes. In our study, a standardized HA filler dermal injection on nasolabial folds did not influence skin biophysical parameters such as skin hydration and elasticity. Nasolabial folds showed a persistent and significative response at T2 confirmed by instrumental evaluation. The tolerability and safety profile of the product was excellent.

  15. Calcium hydroxylapatite treatment of human skin: evidence of collagen turnover through picrosirius red staining and circularly polarized microscopy

    Directory of Open Access Journals (Sweden)

    Zerbinati N

    2018-01-01

    Full Text Available Nicola Zerbinati,1 Alberto Calligaro2 1Department of Surgical and Morphological Sciences, University of Insubria (Varese and Polyspecialist Medical Center, Pavia, 2Department of Public Health, Experimental and Forensic Medicine, Unit of Histology and Embryology, University of Pavia, Pavia, Italy Background: Calcium hydroxylapatite (CaHA, Radiesse® is a biocompatible, injectable filler for facial soft-tissue augmentation that provides volume to tissues, followed by a process of neocollagenesis for improved skin quality. Objective: To examine the effects of CaHA treatment on the molecular organization of collagen using a combination of picrosirius red staining and circularly polarized light microscopy.Methods: Five subjects received subdermal injection of 0.3 mL of CaHA in tissues scheduled for removal during abdominoplasty 2 months later. Tissue specimens from the CaHA injection site and a control untreated area were obtained from excised skin at the time of surgery. Processed tissue sections were stained with picrosirius red solution 0.1% and visualized under circularly polarized light microscopy for identification of thick mature (type I and thin newly formed (type III collagen fibers. Pixel signals from both the control and CaHA-treated areas were extracted from the images, and morphometric computerized hue analysis was performed to provide a quantitative evaluation of mature and newly formed collagen fibers.Results: Under picrosirius red staining and circularly polarized light microscopy, green/yellow areas (thin newly formed collagen type III were visible among the collagen fibers in tissue sections from the area of CaHA injection. In contrast, the majority of the collagen fibers appeared red (thick mature collagen type I in control tissues. Morphometric analysis confirmed that, following CaHA treatment, the proportion of fibers represented by thin newly formed collagen type III increased significantly (p<0.01 in comparison with the

  16. Effectiveness evaluation of two volumizing hyaluronic acid dermal fillers in a controlled, randomized, double-blind, split-face clinical study

    Directory of Open Access Journals (Sweden)

    Kerscher M

    2017-06-01

    Full Text Available Martina Kerscher,1 Karla Agsten,2 Maria Kravtsov,3 Welf Prager4 1Department of Cosmetic Science, University of Hamburg, 2SCIderm GmbH, Hamburg, Germany; 3Anteis S.A., Geneva, Switzerland; 4Prager & Partner Dermatologische Praxis, Hamburg, Germany Background: Enhancement of the midface can be achieved with volumizing hyaluronic acid (HA fillers.Objective: The objective of this study was to compare the safety and effectiveness of Cohesive Polydensified Matrix® 26 mg/mL HA gel (CPM-26 and Vycross® 20 mg/ml HA gel (VYC-20 in a controlled, randomized, evaluator-blind, split-face clinical study.Patients and methods: Subjects with moderate-to-severe malar volume loss on the Merz Aesthetics Scale (MAS received CPM-26 on one side and VYC-20 on the contralateral side of the face. Effectiveness assessments were performed by blinded evaluators including photographic and live MAS ratings and live Global Aesthetic Improvement Scale (GAIS ratings. Calculations of anatomical volume variations at month 3 (M3, month 6 (M6, month 12 (M12 and month 18 (M18 were also performed.Results: Non-inferiority of CPM-26 versus VYC-20 was demonstrated at M3 (primary end point based on MAS. GAIS rating showed that significantly more subjects had better improvement with CPM-26 than with VYC-20 at month 1, M3, M12 and M18 (p=0.0032, p=0.0074, p=0.0384 and p=0.0110, respectively. Standardized evaluation of volume variations from baseline to M3, M12 and M18 showed that CPM-26 created more volume augmentation at all time points, and the difference was significant at M3.Conclusion: CPM-26 was non-inferior to VYC-20 based on MAS ratings at M3 and demonstrated a favorable safety and effectiveness profile for midfacial volume enhancement with results lasting up to M18. Keywords: cohesive polydensified matrix, hyaluronic acid fillers, Belotero® Volume, Modélis® SHAPE, Juvéderm® VOLUMA®, volumizing

  17. The hydroxylapatite-bone interface: 10 years after implant installation.

    NARCIS (Netherlands)

    Beekmans, H.C.; Meijer, G.J.; Barkhuysen, R.; Blijdorp, P.A.; Merkx, M.A.W.; Jansen, J.A.

    2008-01-01

    Reconstruction of a severely atrophied maxilla by sinus augmentation with a mixture of hydroxylapatite (HA) granules and autologous cancellous bone is claimed to be a predictable means to facilitate implant placement. To the authors' knowledge, this is the first human histological case report of

  18. Hyaluronic acid gel fillers in the management of facial aging

    Directory of Open Access Journals (Sweden)

    Fredric S Brandt

    2008-03-01

    Full Text Available Fredric S Brandt1, Alex Cazzaniga21Private Practice in Coral Gables, Florida, USA and Manhattan, NY, USA, and Dermatology Research Institute, Coral Gables, FL, USA; 2Dermatology Research Institute, Coral Gables, Florida, USAAbstract: Time affects facial aging by producing cellular and anatomical changes resulting in the consequential loss of soft tissue volume. With the advent of new technologies, the physician has the opportunity of addressing these changes with the utilization of dermal fillers. Hyaluronic acid (HA dermal fillers are the most popular, non-permanent injectable materials available to physicians today for the correction of soft tissue defects of the face. This material provides an effective, non invasive, non surgical alternative for correction of the contour defects of the face due to its enormous ability to bind water and easiness of implantation. HA dermal fillers are safe and effective. The baby-boomer generation, and their desire of turning back the clock while enjoying an active lifestyle, has expanded the popularity of these fillers. In the US, there are currently eight HA dermal fillers approved for commercialization by the Food and Drug Administration (FDA. This article reviews the innate properties of FDA-approved HA fillers and provides an insight on future HA products and their utilization for the management of the aging face.Keywords: hyaluronic acid, aging face, dermal filler, wrinkles, Restylane, Perlane, Juvéderm

  19. MICROWAVE JOINING OF ALUMINA CERAMIC AND HYDROXYLAPATITE BIOCERAMIC

    Institute of Scientific and Technical Information of China (English)

    1999-01-01

    Microwave joining is a rapid developmental new techniqu e in recent years.This paper introduces a new microwave joining equipment which was made by our lab,succeeds in alumina ceramic-hydroxylapatite bioceramic j o in in the equipment, and analyzes the join situation of join boundary by using s canni ng electron microscope(SEM),this paper analyzes the mechanism of microwave joini ng also.

  20. Treatment of Soft Tissue Filler Complications: Expert Consensus Recommendations.

    Science.gov (United States)

    Urdiales-Gálvez, Fernando; Delgado, Nuria Escoda; Figueiredo, Vitor; Lajo-Plaza, José V; Mira, Mar; Moreno, Antonio; Ortíz-Martí, Francisco; Del Rio-Reyes, Rosa; Romero-Álvarez, Nazaret; Del Cueto, Sofía Ruiz; Segurado, María A; Rebenaque, Cristina Villanueva

    2018-04-01

    Dermal fillers have been increasingly used in minimally invasive facial esthetic procedures. This widespread use has led to a rise in reports of associated complications. The aim of this expert consensus report is to describe potential adverse events associated with dermal fillers and to provide guidance on their treatment and avoidance. A multidisciplinary group of experts in esthetic treatments convened to discuss the management of the complications associated with dermal fillers use. A search was performed for English, French, and Spanish language articles in MEDLINE, the Cochrane Database, and Google Scholar using the search terms "complications" OR "soft filler complications" OR "injectable complications" AND "dermal fillers" AND "Therapy". An initial document was drafted by the Coordinating Committee, and it was reviewed and modified by the experts, until a final text was agreed upon and validated. The panel addressed consensus recommendations about the classification of filler complications according to the time of onset and about the clinical management of different complications including bruising, swelling, edema, infections, lumps and bumps, skin discoloration, and biofilm formation. Special attention was paid to vascular compromise and retinal artery occlusion. Clinicians should be fully aware of the signs and symptoms related to complications and be prepared to confidently treat them. Establishing action protocols for emergencies, with agents readily available in the office, would reduce the severity of adverse outcomes associated with injection of hyaluronic acid fillers in the cosmetic setting. This document seeks to lay down a set of recommendations and to identify key issues that may be useful for clinicians who are starting to use dermal fillers. Additionally, this document provides a better understanding about the diagnoses and management of complications if they do occur. This journal requires that authors assign a level of evidence to each

  1. Dehydration and Rehydration of Carbonated Fluor- and Hydroxylapatite

    Directory of Open Access Journals (Sweden)

    Claude Yoder

    2012-03-01

    Full Text Available The recent definitive deuterium solid state NMR spectroscopic evidence for structural water in fluor- and hydroxylapatites has prompted our study of the conditions necessary for the removal and reincorporation of this important structural feature of apatites. Thermal gravimetric analysis of 20 synthetic carbonated calcium hydroxylapatite (CCaApOH samples and nine carbonated calcium fluorapatite (CCaApF samples has been used to determine the amount of structural and adsorbed water in each sample. No correlation between the weight percent and number of moles of structural water and the weight percent carbonate in CCaApOH and CCaApF has been found. In contrast, there appears to be a relationship between the amount of adsorbed water and the carbonate concentration in the fluorapatites prepared with a two hour digestion time, as well as in the hydroxylapatites prepared with one hour digestion periods, presumably due to the effect of carbonate on crystallite size. Structural water can be removed from the apatite lattice, primarily above 200 °C, but heating to over 550 °C is required for complete removal. This water can be partly reincorporated through an apparently kinetically-controlled process that is enhanced by an increase in time and/or temperature. We speculate that the incorporation of structural water occurs at the beginning of the formation of the apatite structure, approximately coincident with the incorporation of carbonate. We also speculate that water is both removed and reincorporated by proton transfers from water molecules to hydroxide ions.

  2. Fillers in the skin of color population.

    Science.gov (United States)

    Heath, Candrice R; Taylor, Susan C

    2011-05-01

    The skin of color population in the United States is rapidly growing and the cosmetic industry is responding to the demand for skin of color targeted treatments. The aging face in skin of color patients has a unique pattern that can be successfully augmented by dermal fillers. Though many subjects with skin of color were not included in the pre-market dermal filler clinical trials, some post-market studies have examined the safety and risks of adverse events in this population. The safety data from a selection of these studies was examined. Though pigmentary changes occurred, there have been no reports of keloid development. Developing a patient-specific care plan and instituting close follow up is emphasized.

  3. Reversible vs. nonreversible fillers in facial aesthetics: concerns and considerations.

    Science.gov (United States)

    Smith, Kevin Christopher

    2008-08-15

    Soft-tissue augmentation of the face is an increasingly popular cosmetic procedure. In recent years, the number of available filling agents has also increased dramatically, improving the range of options available to physicians and patients. Understanding the different characteristics, capabilities, risks, and limitations of the available dermal and subdermal fillers can help physicians improve patient outcomes and reduce the risk of complications. The most popular fillers are those made from cross-linked hyaluronic acid (HA). A major and unique advantage of HA fillers is that they can be quickly and easily reversed by the injection of hyaluronidase into areas in which elimination of the filler is desired, either because there is excess HA in the area or to accelerate the resolution of an adverse reaction to treatment or to the product. In general, a lower incidence of complications (especially late-occurring or long-lasting effects) has been reported with HA fillers compared with the semi-permanent and permanent fillers. The implantation of nonreversible fillers requires more and different expertise on the part of the physician than does injection of HA fillers, and may produce effects and complications that are more difficult or impossible to manage even by the use of corrective surgery. Most practitioners use HA fillers as the foundation of their filler practices because they have found that HA fillers produce excellent aesthetic outcomes with high patient satisfaction, and a low incidence and severity of complications. Only limited subsets of physicians and patients have been able to justify the higher complexity and risks associated with the use of nonreversible fillers.

  4. Polyurethane Filler for Electroplating

    Science.gov (United States)

    Beasley, J. L.

    1984-01-01

    Polyurethane foam proves suitable as filler for slots in parts electroplated with copper or nickel. Polyurethane causes less contamination of plating bath and of cleaning and filtering tanks than wax fillers used previously. Direct cost of maintenance and indirect cost of reduced operating time during tank cleaning also reduced.

  5. Comparison of Voice Outcome After Vocal Fold Augmentation With Fat or Calcium Hydroxylapatite

    NARCIS (Netherlands)

    Lodder, Wouter L.; Dikkers, Frederik G.

    Objectives/HypothesisTo evaluate the short-term voice outcomes of vocal fold augmentation using fat compared to calcium hydroxylapatite product Radiesse Voice (Merz Aesthetics). Study DesignRetrospective study design. MethodsSixty-six consecutive patients with vocal fold insufficiency were

  6. Host Tissue Interaction, Fate, and Risks of Degradable and Nondegradable Gel Fillers

    DEFF Research Database (Denmark)

    Christensen, Lise

    2009-01-01

    BACKGROUND A constantly increasing number of gel fillers for aesthetic and reconstructive purposes have been introduced during the last 20 years. Most of the new ones are modified versions of the original collagen and hyaluronic acid gels. They have been reconstructed, often by adding cross......-bindings to the polymer in order to obtain a more dense molecular structure, which will prolong degradation and filling effect of the gel. Other gel fillers contain particles of organic (poly-lactic acid) or inorganic (calcium hydroxylapatite) material, which have been used in human tissue for other purposes (degradable...... are based on experimental and clinical observations coupled with a search of the literature. RESULTS AND CONCLUSION Complications following homogenous hydrogels are caused by infection with bacteria, which have been inserted into the gel during injection. If not treated with relevant antibiotics (but...

  7. Blindness caused by cosmetic filler injection: a review of cause and therapy.

    Science.gov (United States)

    Carruthers, Jean D A; Fagien, Steve; Rohrich, Rod J; Weinkle, Susan; Carruthers, Alastair

    2014-12-01

    Vascular occlusion causing blindness is a rare yet greatly feared complication of the use of facial aesthetic fillers. The authors performed a review of the aesthetic literature to ascertain the reported cases of blindness and the literature reporting variations in the vascular anatomy of the human face. The authors suggest a small but potentially helpful addition to the accepted management of the acute case. Cases of blindness, mostly irreversible, from aesthetic filler injections have been reported from Asia, Europe, and North America. Autologous fat appears to be the most frequent filler causing blindness. Some cases of partial visual recovery have been reported with hyaluronic acid and calcium hydroxylapatite fillers. The sudden profusion of new medical and nonmedical aesthetic filler injectors raises a new cause for alarm about patient safety. The published reports in the medical literature are made by experienced aesthetic surgeons and thus the actual incidence may be even higher. Also, newer injectors may not be aware of the variations in the pattern of facial vascular arborization. The authors present a summary of the relevant literature to date and a suggested helpful addition to the protocols for urgent management.

  8. A systematic review of filler agents for aesthetic treatment of HIV facial lipoatrophy (FLA).

    Science.gov (United States)

    Jagdeo, Jared; Ho, Derek; Lo, Alex; Carruthers, Alastair

    2015-12-01

    HIV facial lipoatrophy (FLA) is characterized by facial volume loss. HIV FLA affects the facial contours of the cheeks, temples, and orbits, and is associated with social stigma. Although new highly active antiretroviral therapy medications are associated with less severe FLA, the prevalence of HIV FLA among treated individuals exceeds 50%. The goal of our systematic review is to examine published clinical studies involving the use of filler agents for aesthetic treatment of HIV FLA and to provide evidence-based recommendations based on published efficacy and safety data. A systematic review of the published literature was performed on July 1, 2015, on filler agents for aesthetic treatment of HIV FLA. Based on published studies, poly-L-lactic acid is the only filler agent with grade of recommendation: B. Other reviewed filler agents received grade of recommendation: C or D. Poly-L-lactic acid may be best for treatment over temples and cheeks, whereas calcium hydroxylapatite, with a Food and Drug Administration indication of subdermal implantation, may be best used deeply over bone for focal enhancement. Additional long-term randomized controlled trials are necessary to elucidate the advantages and disadvantages of fillers that have different biophysical properties, in conjunction with cost-effectiveness analysis, for treatment of HIV FLA. Published by Elsevier Inc.

  9. Focal dermal hypoplasia without focal dermal hypoplasia

    NARCIS (Netherlands)

    Contreras-Capetillo, Silvina N.; Lombardi, Maria Paola; Pinto-Escalante, Doris; Hennekam, Raoul C.

    2014-01-01

    Focal dermal hypoplasia (FDH; Goltz-Gorlin syndrome) is an X-linked dominant disorder affecting mainly tissues of ectodermal and mesodermal origin. The phenotype is characterized by hypoplastic linear skin lesions, eye malformations, hair and teeth anomalies, and multiple limbs malformations. The

  10. The effect of therapeutic radiation on canine alveolar ridges augmented with hydroxylapatite

    DEFF Research Database (Denmark)

    Pinholt, E M; Kwon, P H

    1992-01-01

    The purpose of this investigation was to evaluate the effect of radiation on hydroxylapatite (HA) implanted subperiosteally for alveolar ridge augmentation in dogs. All bicuspids and molars were extracted from 16 dogs. After 6 weeks, nonporous HA granules were implanted subperiosteally...... on the alveolar ridge. Following 4 months of healing, 12 dogs (experimental group) underwent therapeutic radiation therapy (Co60, 4,000 rad [40 Gy]) to the head and neck region. Four dogs were not irradiated and served as controls. Four animals (three experimental and one control) were killed at 5,6,7, and 8...

  11. Biogas of sanitary fillers

    International Nuclear Information System (INIS)

    Serrano Camacho, Ciro

    2007-01-01

    The author proposes a methodology for the preliminary estimation of the energetic potential and environmental improvement derivates of the implementation of these technologies that allows to make the first estimative of biogas generation of sanitary fillers with base in the results of the simulation of three predictive model: One Mexican, other denominated Scholl-Canyon of North American origin and the designed by the EPA. The three models use different versions and constants for a differential equation of degradation of first degree

  12. Natural flexible dermal armor.

    Science.gov (United States)

    Yang, Wen; Chen, Irene H; Gludovatz, Bernd; Zimmermann, Elizabeth A; Ritchie, Robert O; Meyers, Marc A

    2013-01-04

    Fish, reptiles, and mammals can possess flexible dermal armor for protection. Here we seek to find the means by which Nature derives its protection by examining the scales from several fish (Atractosteus spatula, Arapaima gigas, Polypterus senegalus, Morone saxatilis, Cyprinius carpio), and osteoderms from armadillos, alligators, and leatherback turtles. Dermal armor has clearly been developed by convergent evolution in these different species. In general, it has a hierarchical structure with collagen fibers joining more rigid units (scales or osteoderms), thereby increasing flexibility without significantly sacrificing strength, in contrast to rigid monolithic mineral composites. These dermal structures are also multifunctional, with hydrodynamic drag (in fish), coloration for camouflage or intraspecies recognition, temperature and fluid regulation being other important functions. The understanding of such flexible dermal armor is important as it may provide a basis for new synthetic, yet bioinspired, armor materials. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Effect of mechanical stress on the Raman and infrared bands of hydroxylapatite: A quantum mechanical first principle investigation.

    Science.gov (United States)

    Ulian, Gianfranco; Valdrè, Giovanni

    2018-01-01

    The calcium apatite minerals are among the most studied in the biomaterial field because of their similarity with the mineral phase of bone tissues, which is mainly the hexagonal polymorph of hydroxylapatite. Given the growing interest both in the microscopic processes governing the behaviour of these natural biomaterials and in recent experimental methods to investigate the Raman response of hydroxylapatite upon mechanical loading, we report in the present work a detailed quantum mechanical analysis by DFT/B3LYP-D* approach on the Raman and infrared responses of hydroxylapatite upon deformation of its unit cell. From the vibrational results, the piezo-spectroscopic components Δν = Π ij σ ij were calculated. For the first time to the authors' knowledge quantum mechanics (QM) was applied to resolve the piezo-spectroscopic response of hydroxylapatite. The QM results on the uniaxial stress responses of this phase on the piezo-spectroscopic components Π 11 and Π 33 of the symmetric P-O stretching mode were 2.54 ± 0.09cm -1 /GPa and 2.56 ± 0.06cm -1 /GPa, respectively (Raman simulation) and 2.48 ± 0.15cm -1 /GPa and Π 33 = 2.74 ± 0.08cm -1 /GPa, respectively, of the asymmetric P-O stretching (infrared spectroscopy simulation). These results are in excellent agreement with previous experimental data reported in literature. The quantum mechanical analysis of the other vibrational bands (not present in literature) shed more light on this new and very important application of both Raman and IR spectroscopies and extend the knowledge of the behaviour of hydroxylapatite, suggesting and addressing further experimental research and analytic strategy. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Research progress of composite fillers

    Directory of Open Access Journals (Sweden)

    Yixuan ZHAO

    2015-08-01

    Full Text Available Using composite filler is a very potential way to braze dissimilar material, especially braze metals with ceramics. The composite filler which is added varieties of high temperature alloy, carbon fiber and ceramic particles has a suitable coefficient of thermal expansion. The application of composite filler can release the residual stress caused by mismatch of thermal expansion coefficient in the brazing joints and improve the overall performance significantly. According to the traditional classification method of composite materials, the composite filler is divided into micron-reinforced composite filler and nano-reinforced composite filler, of which the feature and research status are discussed in this text. According to the influence of different size reinforced phases on microstructure and mechanical property of the brazing joints, nano-reinforced composite filler has more uniform and better structure compared with micron-reinforced composite filler, and higher joint strengh can be obtained by using it. However, the reinforced mechanism is still an open question, and will become the key area of the future research work.

  15. Preparation and properties of polyvinyl alcohol (PVA) and hydroxylapatite (HA) hydrogels for cartilage tissue engineering.

    Science.gov (United States)

    Yuan, F; Ma, M; Lu, L; Pan, Z; Zhou, W; Cai, J; Luo, S; Zeng, W; Yin, F

    2017-05-20

    A novel bioactive hydrogel for cartilage tissue based on polyvinyl alcohol (PVA) and hydroxylapatite (HA) were prepared, the effects of its component contents on the mechanical properties and microstructure of the hydrogel were investigated. The important properties of the scaffold composites, such as density, porosity, compressive modulus and microstructure were studied and analyzed through various measurements and methods. The biodegradability of hydrogel was evaluated by soaking the samples into artificial degradation solution at body temperature (36 - 37 oC) in vitro. Experimental results showed that the PVA/HA hydrogels had a density of 0.572 - 0.683 g/cm3, a porosity of 63.25 - 96.14% and a compressive modulus of 5.62 - 8.24 MP. The HA compound in the hydrogels enhanced the biodegradation significantly and linearly increased the rate of biodegradation by 2.3 - 8.5 %. The compressive modulus of PVA/HA exhibited a linear reduce to 0.86 - 1.53 MP with the time of degradation. The scaffold composites PVA/HA possess a high porosity, decent compressive modulus and good biodegradability. After further optimizing the structure and properties, this composite might be considered as novel hydrogel biomaterials to be applied in the field of cartilage tissue engineering.

  16. Characterization of colloidal manganese hydroxylapatite: A potential magnetic resonance contrast agent

    Science.gov (United States)

    Dorshow, Richard B.; Kofi Adzamli, I.; Nosco, Dennis L.; Joslin, Frederick L.

    1996-03-01

    Particulate contrast agents for blood pool imaging need to be constructed with the appropriate particle size distribution (PSD), and need to be resistant to opsonization. Hence, the PSD of an aqueous colloidal suspension of polyethylene glycol (PEG)-stabilized manganese hydroxylapatite (potentially useful as a magnetic resonance contrast agent for blood pool imaging) has been investigated as a function of PEG concentration and molecular weight. At low PEG concentrations, dynamic light scattering (DLS) and sedimentation field flow fractionation measurements yield a broad PSD, with the largest particle diameters near 100nm. Flow field flow fractionation (FlFFF) measurements, however, yield a distinct population near 10nm, which is not readily detectable by the other two techniques. As the PEG concentration is increased, the PSD shifts toward the lower size population. At the highest PEG concentration employed, only particles of diameter 10nm remain, verified by both FlFFF and DLS. Thus, the search for an optimum PSD for blood pool imaging is facilitated by choice of PEG molecular weight and concentration, and by employing complementary use of light scattering and field flow fractionation techniques.

  17. Restoring jawline contour with calcium hydroxylapatite: A prospective, observational study.

    Science.gov (United States)

    Baspeyras, Martine; Dallara, Jean-Marie; Cartier, Hugues; Charavel, Marie-Hélène; Dumas, Laurent

    2017-09-01

    Jawline reshaping by replacing volume has become an indispensable component of modern facial rejuvenation. To evaluate calcium hydroxylapatite (CaHA) for the treatment of an aging jawline in a routine setting. Five investigators enrolled 35 subjects requesting jawline rejuvenation with CaHA. Injections were performed according to investigators usual practice. Baseline and post-treatment scores were evaluated using Merz Aesthetics Scales®. Follow-up visits took place at Day 30 (Day 60 for those with touch-up at Day 30), 180, and 360. Physician and patient satisfaction, esthetic impact of treatment, and adverse events were recorded. Improvements in jawline contour compared with baseline were statistically significant at each visit, with scores of 2.42 (moderate to severe sagging) at baseline, 1.02 (mild) at Day 30/60 (P≤.0001), 1.11 at Day 180 (P≤.0001), and 1.45 at Day 360 (P=.0015). Statistically significant improvements in marionette line scores were also observed. Investigators rated results as "improved" to "very much improved" in all subjects up to Day 180, and in 81% of subjects at Day 360. Satisfaction with treatment was very high. Adverse events were mostly mild and related to either the procedure or injection technique. CaHA is a very effective agent for restoring jawline contour in routine practice and is associated with high levels of physician and patient satisfaction. © 2017 Wiley Periodicals, Inc.

  18. Plasma-Sprayed Hydroxylapatite-Based Coatings: Chemical, Mechanical, Microstructural, and Biomedical Properties

    Science.gov (United States)

    Heimann, Robert B.

    2016-06-01

    This contribution discusses salient properties and functions of hydroxylapatite (HA)-based plasma-sprayed coatings, including the effect on biomedical efficacy of coating thickness, phase composition and distribution, amorphicity and crystallinity, porosity and surface roughness, cohesion and adhesion, micro- and nano-structured surface morphology, and residual coating stresses. In addition, it will provide details of the thermal alteration that HA particles undergo in the extremely hot plasma jet that leads to dehydroxylated phases such as oxyhydroxylapatite (OHA) and oxyapatite (OA) as well as thermal decomposition products such as tri-(TCP) and tetracalcium phosphates (TTCP), and quenched phases such as amorphous calcium phosphate (ACP). The contribution will further explain the role of ACP during the in vitro interaction of the as-deposited coatings with simulated body fluid resembling the composition of extracellular fluid (ECF) as well as the in vivo responses of coatings to the ECF and the host tissue, respectively. Finally, it will briefly describe performance profiles required to fulfill biological functions of osteoconductive bioceramic coatings designed to improve osseointegration of hip endoprostheses and dental root implants. In large parts, the content of this contribution is a targeted review of work done by the author and his students and coworkers over the last two decades. In addition, it is considered a stepping stone toward a standard operation procedure aimed at depositing plasma-sprayed bioceramic implant coatings with optimum properties.

  19. Optimizing outcomes with polymethylmethacrylate fillers.

    Science.gov (United States)

    Gold, Michael H; Sadick, Neil S

    2018-03-30

    The ideal filler should be long-lasting, biocompatible, chemically inert, soft and easy to use, and have a long history of safety. This review focuses on the evolution and development of the PMMA-collagen gel, Bellafill, and the 10 years of postmarketing experience of Bellafill since it received premarket approval (PMA) from the FDA as Artefill in 2006. Artefill was rebranded to Bellafill in 2015. The authors conducted a literature search on PubMed for key articles describing the steps in which Arteplast, a PMMA filler developed in 1989, led to the development of Bellafill, the only PMMA filler approved by the US FDA for the treatment of nasolabial folds and acne scar correction. The factors governing efficacy and safety were also evaluated for the major PMMA fillers available in the world. The process of manufacturing and purifying PMMA has played a major role in minimizing adverse events for Bellafill. Postmarketing surveillance data for the 2007-2016 period show that for more than 530 000 Bellafill syringes distributed worldwide, 11 confirmed granulomas (excluding clinical trial data) (0.002% of syringes sold) have been reported. Data on other PMMA fillers are limited and inconsistent. The authors suggest that adverse events are often attributable to lack of proficiency in treatment technique and other factors. Bellafill has demonstrated an excellent safety and effectiveness profile in multiple clinical studies, customer feedback, and 10 years of postmarketing surveillance experience. Adverse events occur with all fillers for a variety of reasons. In addition to quality of the product, injector skill and technique are critical to ensuring good clinical outcomes. © 2018 Wiley Periodicals, Inc.

  20. Biological background of dermal substitutes

    NARCIS (Netherlands)

    van der Veen, V. C.; van der Wal, M.B.; van Leeuwen, M.C.; Ulrich, M.; Middelkoop, E.

    2010-01-01

    Dermal substitutes are of major importance in treating full thickness skin defects, both in acute and chronic wounds. In this review we will outline specific requirements of three classes of dermal substitutes:-natural biological materials, with a more or less intact extracellular matrix

  1. Joint Workplan on Filler Investigations for DPCs.

    Energy Technology Data Exchange (ETDEWEB)

    Hardin, Ernest [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brady, Patrick Vane [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-12-01

    This workplan addresses filler attributes (i.e., possible requirements), assumptions needed for analysis, selection of filler materials, testing needs, and a long-range perspective on R&D activities leading to filler demonstration and a safety basis for implementation.

  2. Preparation, characterization of electrospun meso-hydroxylapatite nanofibers and their sorptions on Co(II)

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hualin, E-mail: hlwang@hfut.edu.cn [School of Chemical Technology, Hefei University of Technology, Hefei, Anhui 230009 (China); Zhang, Peng; Ma, Xingkong; Jiang, Suwei; Huang, Yan; Zhai, Linfeng [School of Chemical Technology, Hefei University of Technology, Hefei, Anhui 230009 (China); Jiang, Shaotong [School of Biotechnology and Food Engineering, Hefei University of Technology, Hefei, Anhui 230009 (China)

    2014-01-30

    Highlights: • PVA/HA nanofibers could change into meso-HA nanofibers by calcination process. • Sorption of Co(II) on meso-HA was strongly dependent on pH and ionic strength. • Sorption kinetic data were well fitted by the pseudo-second-order rate equation. • Sorption isotherms could be well described by the Langmuir model. • Sorption process of Co(II) on meso-HA nanofibers was spontaneous and endothermic. -- Abstract: In this work, mesoporous hydroxylapatite (meso-HA) nanofibers were prepared via calcination process with polyvinyl alcohol/HA (PVA/HA) hybrid nanofibers fabricated by electrospinning technique as precursors, and the removal efficiency of meso-HA nanofibers toward Co(II) was evaluated via sorption kinetics and sorption isotherms. Furthermore, the sorption behaviors of Co(II) on meso-HA nanofibers were explored as a function of pH, ionic strength, and thermodynamic parameters. There existed hydrogen bonds between HA and PVA matrix in precursor nanofibers which could change into meso-HA nanofibers with main pore diameter at 27 nm and specific surface area at 114.26 m{sup 2}/g by calcination process. The sorption of Co(II) on meso-HA was strongly dependent on pH and ionic strength. Outer-sphere surface complexation or ion exchange was the main mechanisms of Co(II) adsorption on meso-HA at low pH, whereas inner-sphere surface complexation was the main adsorption mechanism at high pH. The sorption kinetic data were well fitted by the pseudo-second-order rate equation. The sorption isotherms could be well described by the Langmuir model. The thermodynamic parameters (ΔH°, ΔS° and ΔG°) calculated from the temperature-dependent sorption isotherms suggested that the sorption process of Co(II) on meso-HA nanofibers was spontaneous and endothermic.

  3. Microfocused Ultrasound with Visualization and Calcium Hydroxylapatite for Improving Skin Laxity and Cellulite Appearance

    Science.gov (United States)

    Pereira, Gregório

    2017-01-01

    Background: Age-associated skin laxity contributes to worsening of cellulite appearance. This study evaluated the effects of microfocused ultrasound with visualization (MFU-V; Ultherapy) in combination with diluted calcium hydroxylapatite (CaHA; Radiesse) on cellulite appearance and on neocollagenesis. Methods: Twenty women (18–55 years old) with skin laxity and moderate-to-severe cellulite on the buttocks and thighs were retrospectively enrolled. MFU-V was applied using 4 and 7 MHz transducers (25 lines/transducer/site) and immediately followed by subdermal CaHA injection (1 ml/buttock or thigh). Photographs at baseline and 90 days were assessed by 2 independent, blinded evaluators using a 5-item cellulite severity scale. One subject scheduled for thighplasty received treatment with 6 different CaHA dilutions (0.3 ml/5 cm2) followed by MFU-V. Tissue specimens from each dilution site were examined under polarized light microscopy to assess neocollagenesis. Results: Both evaluators reported statistically significant improvements compared with baseline for each item on the cellulite severity scale (P treatment. At 90 days, histologic analysis showed peak neocollagenesis in samples treated with the 1:1 dilution, whether with CaHA alone or in combination with MFU-V. The highest conversion of collagen type III into collagen type I at month 3 occurred in samples injected with 1:1 and 1:0.6 CaHA dilutions without subsequent MFU-V treatment. Both procedures were well tolerated, and subject satisfaction was high. Conclusions: Combination treatment with MFU-V and diluted CaHA is effective for improving skin laxity and the appearance of cellulite on the buttocks and upper thighs. PMID:28831339

  4. An evaluation of calcium hydroxylapatite (Radiesse) for cosmetic nasolabial fold correction: a meta-analysis and patient centric outcomes study.

    Science.gov (United States)

    Fakhre, G Peter; Perdikis, Galen; Shaddix, Kyle K; Terkonda, Sarvam P; Waldorf, James C

    2009-11-01

    The use of calcium hydroxylapatite (Radiesse, BioForm Medical, San Mateo, California) for cosmetic soft tissue augmentation has increased significantly in recent years. Only a handful of authors have reported patient satisfaction data. A meta-analysis of published data was performed using a 5-point scale for patient satisfaction to allow data comparison across studies. A patient-centric outcomes study was also performed at our institution, using a blinded questionnaire. Five usable studies were identified for meta-analysis. Patient satisfaction was 4.16 of 5 in 324 patients at 3 to 6 months and 4.15 in 86 patients at 1 year. In our institutional patient-centric outcomes study, the early satisfaction rate was 3.7 of 5. At 1 year the rate was only 2.3 of 5. Calcium hydroxylapatite remains a viable option for augmentation of facial soft tissue structures. However, this report shows that further, accurate, large population outcomes assessments are absolutely required.

  5. The impact of fillers on lineup performance.

    Science.gov (United States)

    Wetmore, Stacy A; McAdoo, Ryan M; Gronlund, Scott D; Neuschatz, Jeffrey S

    2017-01-01

    Filler siphoning theory posits that the presence of fillers (known innocents) in a lineup protects an innocent suspect from being chosen by siphoning choices away from that innocent suspect. This mechanism has been proposed as an explanation for why simultaneous lineups (viewing all lineup members at once) induces better performance than showups (one-person identification procedures). We implemented filler siphoning in a computational model (WITNESS, Clark, Applied Cognitive Psychology 17:629-654, 2003), and explored the impact of the number of fillers (lineup size) and filler quality on simultaneous and sequential lineups (viewing lineups members in sequence), and compared both to showups. In limited situations, we found that filler siphoning can produce a simultaneous lineup performance advantage, but one that is insufficient in magnitude to explain empirical data. However, the magnitude of the empirical simultaneous lineup advantage can be approximated once criterial variability is added to the model. But this modification works by negatively impacting showups rather than promoting more filler siphoning. In sequential lineups, fillers were found to harm performance. Filler siphoning fails to clarify the relationship between simultaneous lineups and sequential lineups or showups. By incorporating constructs like filler siphoning and criterial variability into a computational model, and trying to approximate empirical data, we can sort through explanations of eyewitness decision-making, a prerequisite for policy recommendations.

  6. Sifat filler kayu keruing terhadap vulkanisat karet

    Directory of Open Access Journals (Sweden)

    Herminiwati Herminiwati

    1999-12-01

    Full Text Available The purpose of this research was to investigate the properties of keruing wood filler in their application on vulacanized rubber of shoes soles. To know its suitability for rubber goods filler, the properties of keruing wood filler was investigated by comparing with carbon black N330. Keruing wood filler were made by carbonization process at temperature 450oC for one hour and activation process with NaCl 4% for twenty four hours, followed by pyrolisis at temperature 500oC for one hour. Filler were milled and sieved by 400 mesh siefter. The standard compound formula was prepared base on ASTM D 3192 with various filler level of keruing wood filler, carbon black N330 either separately formulated of combination. The research showed that using keruing wood filler in the amount of 30-70 phr could meet 75% the requirements of SNI. 12-0172-1987 : Canvas shoes for general purpose, where as carbon black N330 in the amount of 30-70 phr could meet 87,5% the requirements of SNI. 12-0172-1987. Combination of keruing wood filler and carbon black showed that keruing wood filler could substitute 25-57 phr of carbon black.

  7. Soy-based fillers for thermoset composites

    Science.gov (United States)

    Watt, Paula

    Considerable work has been done with bio-based fillers in thermoplastics. Wood dust has been used for decades in wood plastic composites in conjunction with recycled high HDPE and PET. In recent years rapidly renewable fillers derived from dried distillery grains and from wood have been introduced commercially for thermoset polymers. These fillers provide bio-content and weight reduction to thermoset molding compounds but issues with moisture absorption and polymerization inhibition have limited their commercial acceptance. The intent of this research was to develop a bio-based filler suitable for thermoset composites. This filler would provide a low density alternative to mined mineral filler, such as CaCO3 or clay. Composites made with these fillers would be lighter in weight, which is desirable for many markets, particularly transportation. Cost parity to the mineral fillers, on a volume basis, was desirable and the use of green chemistry principles was a key objective of the project. This work provides a basis from which further development of modified soy flours as fillers for thermoset composites will continue. Biomass has been evaluated as fillers for thermoset composites since the early 1980s but failed to gain commercial acceptance due to excessive water absorption and inhibition issues with free radical curing. Biomass, with a large percentage of carbohydrates, are very hydrophilic due to their abundance of hydroxyl groups, while biomass, high in lignin, resulted in inhibition of the free radical cure of the unsaturated styrenated polyester matrix systems. Generally protein use as a filler is not desirable due to its food value. Torrefaction has proved to be a good, cost effective, process to reduce hydrophilicity of high cellulose feedstock. Surprising, however, some levels of torrefaction were found to induce the inhibition effect of the filler. Scientific inquiry into this problem proved that aromatics form during the torrefaction process and can

  8. EVALUATING COMMERCIALLY AVAILABLE DERMAL ...

    Science.gov (United States)

    As the Human Exposure Program focuses on the exposure of children to pesticides, there are concerns about the effect, or perceived effect, of components of the sampling procedure on the health and well-being of the infant and the ability to collect pesticide residues. One concern involves the materials in wipes used to collect pesticide residues or other contact materials on the skin. In recent studies (e.g., National Human Exposure Assessment Survey; NHEXAS), isopropyl alcohol has been used as a solvent in conjunction with a cloth wipe to obtain samples from the hands of adults and children. Although isopropyl alcohol is generally considered innocuous, the use of commercially available products could eliminate concerns about exposure to alcohol. A few studies have evaluated the potential of commercially available baby wipes to collect personal exposure samples for metals research, but not for the area of pesticide research (Millson et al., 1994; Campbell et al., 1993; Lichtenwalner et al., 1993). Therefore, there is a need to evaluate the potential for using commercially available baby wipes for collecting pesticide samples from skin and other surfaces. Another concern involves establishing a convenient and safe method for assessing overall dermal exposure for children, especially for those in crawling stage. One route that the U .S. Environmental Protection Agency (EPA) would like to investigate is the use of cotton body suits (infant sleepers) as an indicator

  9. Does filler database size influence identification accuracy?

    Science.gov (United States)

    Bergold, Amanda N; Heaton, Paul

    2018-06-01

    Police departments increasingly use large photo databases to select lineup fillers using facial recognition software, but this technological shift's implications have been largely unexplored in eyewitness research. Database use, particularly if coupled with facial matching software, could enable lineup constructors to increase filler-suspect similarity and thus enhance eyewitness accuracy (Fitzgerald, Oriet, Price, & Charman, 2013). However, with a large pool of potential fillers, such technologies might theoretically produce lineup fillers too similar to the suspect (Fitzgerald, Oriet, & Price, 2015; Luus & Wells, 1991; Wells, Rydell, & Seelau, 1993). This research proposes a new factor-filler database size-as a lineup feature affecting eyewitness accuracy. In a facial recognition experiment, we select lineup fillers in a legally realistic manner using facial matching software applied to filler databases of 5,000, 25,000, and 125,000 photos, and find that larger databases are associated with a higher objective similarity rating between suspects and fillers and lower overall identification accuracy. In target present lineups, witnesses viewing lineups created from the larger databases were less likely to make correct identifications and more likely to select known innocent fillers. When the target was absent, database size was associated with a lower rate of correct rejections and a higher rate of filler identifications. Higher algorithmic similarity ratings were also associated with decreases in eyewitness identification accuracy. The results suggest that using facial matching software to select fillers from large photograph databases may reduce identification accuracy, and provides support for filler database size as a meaningful system variable. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  10. The impact of fillers on lineup performance

    OpenAIRE

    Wetmore, Stacy A.; McAdoo, Ryan M.; Gronlund, Scott D.; Neuschatz, Jeffrey S.

    2017-01-01

    Filler siphoning theory posits that the presence of fillers (known innocents) in a lineup protects an innocent suspect from being chosen by siphoning choices away from that innocent suspect. This mechanism has been proposed as an explanation for why simultaneous lineups (viewing all lineup members at once) induces better performance than showups (one-person identification procedures). We implemented filler siphoning in a computational model (WITNESS, Clark, Applied Cognitive Psychology 17:629...

  11. Current Concepts in Filler Injection.

    Science.gov (United States)

    Moradi, Amir; Watson, Jeffrey

    2015-11-01

    When evaluating the face in thirds, the upper face, midface, and lower face, one may assume the lateral the temple, midface, and lateral mandible as the pillars of these subdivisions. Many of our facial aesthetic procedures address these regions, including the lateral brow lift, midface lift, and lateral face lift. As the use of facial fillers has advanced, more emphasis is placed on the correction of the temples, midlateral face, and lateral jaw line. This article is dedicated to these facial aesthetic pillars. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Dermal extracellular lipid in birds.

    Science.gov (United States)

    Stromberg, M W; Hinsman, E J; Hullinger, R L

    1990-01-01

    A light and electron microscopic study of the skin of domestic chickens, seagulls, and antarctic penguins revealed abundant extracellular dermal lipid and intracellular epidermal lipid. Dermal lipid appeared ultrastructurally as extracellular droplets varying from less than 1 micron to more than 25 microns in diameter. The droplets were often irregularly contoured, sometimes round, and of relatively low electron density. Processes of fibrocytes were often seen in contact with extracellular lipid droplets. Sometimes a portion of such a droplet was missing, and this missing part appeared to have been "digested away" by the cell process. In places where cells or cell processes are in contact with fact droplets, there are sometimes extracellular membranous whorls or fragments which have been associated with the presence of fatty acids. Occasionally (in the comb) free fat particles were seen in intimate contact with extravasated erythrocytes. Fat droplets were seen in the lumen of small dermal blood and lymph vessels. We suggest that the dermal extracellular lipid originates in the adipocyte layer and following hydrolysis the free fatty acids diffuse into the epidermis. Here they become the raw material for forming the abundant neutral lipid contained in many of the epidermal cells of both birds and dolphins. The heretofore unreported presence and apparently normal utilization of abundant extracellular lipid in birds, as well as the presence of relatively large droplets of neutral lipid in dermal vessels, pose questions which require a thorough reappraisal of present concepts of the ways in which fat is distributed and utilized in the body.

  13. From dermal exposure to internal dose

    NARCIS (Netherlands)

    Sandt, J.J.M. van de; Dellarco, M.; Hemmen, J.J. van

    2007-01-01

    Exposure scenarios form an essential basis for chemical risk assessment reports under the new EU chemicals regulation REACH (Registration, Evaluation, Authorisation and restriction of Chemicals). In case the dermal route of exposure is predominant, information on both exposure and dermal

  14. Genetics Home Reference: focal dermal hypoplasia

    Science.gov (United States)

    ... in people with focal dermal hypoplasia is an omphalocele , which is an opening in the wall of ... Dermal Hypoplasia MedlinePlus Encyclopedia: Ectodermal dysplasia MedlinePlus Encyclopedia: Omphalocele General Information from MedlinePlus (5 links) Diagnostic Tests ...

  15. Fillers as Signs of Distributional Learning

    Science.gov (United States)

    Taelman, Helena; Durieux, Gert; Gillis, Steven

    2009-01-01

    A longitudinal analysis is presented of the fillers of a Dutch-speaking child between 1;10 and 2;7. Our analysis corroborates familiar regularities reported in the literature: most fillers resemble articles in shape and distribution, and are affected by rhythmic and positional constraints. A novel finding is the impact of the lexical environment:…

  16. Adverse reactions to injectable soft tissue fillers

    DEFF Research Database (Denmark)

    Requena, Luis; Requena, Celia; Christensen, Lise

    2011-01-01

    In recent years, injections with filler agents are often used for wrinkle-treatment and soft tissue augmentation by dermatologists and plastic surgeons. Unfortunately, the ideal filler has not yet been discovered and all of them may induce adverse reactions. Quickly biodegradable or resorbable ag...

  17. Self Compacting Concrete with Chalk Filler

    DEFF Research Database (Denmark)

    Sørensen, Eigil V.

    2007-01-01

    Utilisation of Danish chalk filler has been investigated as a means to produce self compacting concrete (SCC) at lower strength levels for service in non aggressive environments. Stable SCC mixtures were prepared at chalk filler contents up to 60% by volume of binder to yield compressive strengths...

  18. Rheology of cement mixtures with dolomite filler

    Directory of Open Access Journals (Sweden)

    Martínez de la Cuesta, P. J.

    2000-06-01

    Full Text Available This experimental program has studied the behavior of fresh paste made up from cements mixed with dolomite filler. Through prior experiments the starting point is obtained for the designs 22 and 23 factorials. With these designs the governing equations are established that influence the specific surface of the filler, the filler percentage and the ratio water/(cement + filler, used as objective functions: test probe penetration, flow on table and shear stress in viscometer. Also the type of rheological conduct is determined and the influence over initial and final setting is observed.

    Este programa experimental estudia el comportamiento de las pastas frescas fabricadas a partir de cementos mezclados con filler dolomítico. En los experimentos previos se obtiene el punto central para los diseños 22 y 23 factoriales. Con estos diseños se establecen las ecuaciones que rigen la influencia de la superficie específica del filler, el porcentaje de filler y la relación agua/(cemento + filler, utilizando como funciones objetivos la penetración de sonda, la mesa de sacudidas y la tensión de corte en el viscosímetro. También se determina el tipo de conducta reológica y la influencia sobre el principio y fin de fraguado.

  19. 7 CFR 58.514 - Container fillers.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Container fillers. 58.514 Section 58.514 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards....514 Container fillers. Shall comply with the 3-A Sanitary Standards for Equipment for Packaging Frozen...

  20. Penile Girth Enhancement With Polymethylmethacrylate-Based Soft Tissue Fillers.

    Science.gov (United States)

    Casavantes, Luis; Lemperle, Gottfried; Morales, Palmira

    2016-09-01

    An unknown percentage of men will take every risk to develop a larger penis. Thus far, most injectables have caused serious problems. Polymethylmethacrylate (PMMA) microspheres have been injected as a wrinkle filler and volumizer with increasing safety since 1989. To report on a safe and permanently effective method to enhance penile girth and length with an approved dermal filler (ie, PMMA). Since 2007, the senior author has performed penile augmentation in 752 men mainly with Metacrill, a suspension of PMMA microspheres in carboxymethyl-cellulose. The data of 729 patients and 203 completed questionnaires were evaluated statistically. The overall satisfaction rate was 8.7 on a scale of 1 to 10. After one to three injection sessions, average girth increased by 3.5 cm, or 134% (10.2 to 13.7 cm = 134.31%). Penile length also increased by weight and stretching force of the implant from an average of 9.8 to 10.5 cm. Approximately half the patients perceived some irregularities of the implant, which caused no problems. Complications occurred in 0.4%, when PMMA nodules had to be surgically removed in three of the 24% of patients who had a non-circumcised penis. After 5 years of development, penile augmentation with PMMA microspheres appears to be a natural, safe, and permanently effective method. The only complication of nodule formation and other irregularities can be overcome by an improved injection technique and better postimplantation care. Copyright © 2016 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.

  1. Dermal uptake of petroleum substances.

    Science.gov (United States)

    Jakasa, Ivone; Kezic, Sanja; Boogaard, Peter J

    2015-06-01

    Petroleum products are complex substances comprising varying amounts of linear and branched alkanes, alkenes, cycloalkanes, and aromatics which may penetrate the skin at different rates. For proper interpretation of toxic hazard data, understanding their percutaneous absorption is of paramount importance. The extent and significance of dermal absorption of eight petroleum substances, representing different classes of hydrocarbons, was evaluated. Literature data on the steady-state flux and permeability coefficient of these substances were evaluated and compared to those predicted by mathematical models. Reported results spanned over 5-6 orders of magnitude and were largely dependent on experimental conditions in particular on the type of the vehicle used. In general, aromatic hydrocarbons showed higher dermal absorption than more lipophilic aliphatics with similar molecular weight. The results showed high variation and were largely influenced by experimental conditions emphasizing the need of performing the experiments under "in use" scenario. The predictive models overestimated experimental absorption. The overall conclusion is that, based on the observed percutaneous penetration data, dermal exposure to petroleum hydrocarbons, even of aromatics with highest dermal absorption is limited and highly unlikely to be associated with health risks under real use scenarios. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. MODIFICATION OF PAPERMAKING GRADE FILLERS: A BRIEF REVIEW

    Directory of Open Access Journals (Sweden)

    Jing Shen

    2009-08-01

    Full Text Available The use of fillers in paper products can provide cost and energy savings, improved paper properties, increased productivities, and specifically desired paper functionalities. There are many problems associated with the use of fillers, such as unsuitability of calcium carbonate fillers in acid papermaking, negative effects of filler loading on paper strength, sizing, and retention, and tendencies of fillers to cause abrasion and dusting. In order to solve these problems and to make better use of fillers, many methods have been proposed, among which filler modification has been a hot topic. The available technologies of filler modification mainly include modification with inorganic substances, modification with natural polymers or their derivatives, modification with water-soluble synthetic polymers, modification with surfactants, modification with polymer latexes, hydrophobic modification, cationic modification, surface nano-structuring, physical modification by compressing, calcination or grinding, and modification for use in functional papers. The methods of filler modification can provide improved acid tolerant and optical properties of fillers, enhanced fiber-filler bonding, improved filler retention and filler sizabilities, alleviated filler abrasiveness, improved filler dispersability, and functionalization of filled papers. Filler modification has been an indispensable way to accelerate the development of high filler technology in papermaking, which is likely to create additional benefits to papermaking industry in the future.

  3. Thermal Analysis of Filler Reinforced Polymeric Composites

    Science.gov (United States)

    Ghadge, Mahesh Devidas

    Improving heat dissipating property of composite materials is becoming increasingly important in domains ranging from the automotive industry, electronic devices to aeronautical industry. Effective heat dissipation is required especially in aircraft and racing tires to guarantee high performance and good service life [1]. The present study is focused on improving the thermal conductivity of Emulsion-styrene butadiene rubber (ESBR) which is a cheap alternative to other rubber composites. The disadvantages of ESBR are low thermal conductivity and high heat generation. Adding fillers with high thermal conductivity to ESBR is proposed as a technique for improving the thermal conductivity of ESBR. The purpose of the research is to predict the thermal conductivity of ESBR when filled with fillers of much higher thermal conductivity and also to find out to what extent the filler properties affect the heat transfer capabilities of the composite matrix. The influence of different filler shapes i.e. spherical, cylindrical and platelets on the overall thermal capability of composite matrix is studied, the finite element modelings are conducted using Abaqus. Three-dimensional and two-dimensional models are created in Abaqus to simulate the microstructure of the composite matrix filled with fillers. Results indicate that the overall thermal conductivity increases with increasing filler loading i.e. for a filler volume fraction of 0.27, the conductivity increased by around 50%. Filler shapes, orientation angle, and aspect ratio of the fillers significantly influences the thermal conductivity. Conductivity increases with increasing aspect ratio (length/diameter) of the cylindrical fillers since longer conductive chains are able to form at the same volume percentage as compared to spherical fillers. The composite matrix reaches maximum thermal conductivity when the cylindrical fillers are oriented in the direction of heat flow. The heat conductivity predicted by FEM for ESBR is

  4. Characterization of product RNAs synthesized in vitro by poliovirus RNA polymerase purified by chromatography on hydroxylapatite or poly(U) Sepharose.

    OpenAIRE

    Young, D C; Tobin, G J; Flanegan, J B

    1987-01-01

    The size of the product RNA synthesized by the poliovirus RNA polymerase and host factor was significantly affected by the type of column chromatography used to purify the polymerase. Dimer length product RNA was synthesized by the polymerase purified by chromatography on hydroxylapatite. This contrasted with the monomer length product RNA synthesized by the polymerase purified by chromatography on poly(U) Sepharose. The poly(U) Sepharose-purified polymerase was shown to contain oligo(U) that...

  5. Characteristic Asphalt Concrete Wearing Course (ACWC) Using Variation Lime Filler

    Science.gov (United States)

    Permana, R. A.; Pramesti, F. P.; Setyawan, A.

    2018-03-01

    This research use of lime filler Sukaraja expected add durability layers of concrete pavement is asphalt damage caused by the weather and load traffic. This study attempts to know how much value characteristic Marshall on a mixture of concrete asphalt using lime filler. This research uses experimental methods that is with a pilot to get results, thus will look filler utilization lime on construction concrete asphalt variation in filler levels 2 %, 3 %, 4 %.The results showed that the use of lime filler will affect characteristic a mixture of concrete asphalt. The more filler chalk used to increase the value of stability. On the cretaceous filler 2 % value of stability is 1067,04 kg. When lime filler levels added to the levels of filler 4 %, the value of stability increased to 1213,92 kg. The flexibility increased the number of filler as levels lime 2 % to 4 % suggests that are conducted more stiff mix.

  6. [Penile augmentation using acellular dermal matrix].

    Science.gov (United States)

    Zhang, Jin-ming; Cui, Yong-yan; Pan, Shu-juan; Liang, Wei-qiang; Chen, Xiao-xuan

    2004-11-01

    Penile enhancement was performed using acellular dermal matrix. Multiple layers of acellular dermal matrix were placed underneath the penile skin to enlarge its girth. Since March 2002, penile augmentation has been performed on 12 cases using acellular dermal matrix. Postoperatively all the patients had a 1.3-3.1 cm (2.6 cm in average) increase in penile girth in a flaccid state. The penis had normal appearance and feeling without contour deformities. All patients gained sexual ability 3 months after the operation. One had a delayed wound healing due to tight dressing, which was repaired with a scrotal skin flap. Penile enlargement by implantation of multiple layers of acellular dermal matrix was a safe and effective operation. This method can be performed in an outpatient ambulatory setting. The advantages of the acellular dermal matrix over the autogenous dermal fat grafts are elimination of donor site injury and scar and significant shortening of operation time.

  7. Adsorption of Cd(II) and Cu(II) from aqueous solution by carbonate hydroxylapatite derived from eggshell waste

    International Nuclear Information System (INIS)

    Zheng Wei; Li Xiaoming; Yang Qi; Zeng Guangming; Shen Xiangxin; Zhang Ying; Liu Jingjin

    2007-01-01

    Carbonate hydroxylapatite (CHAP) synthesized by using eggshell waste as raw material has been investigated as metal adsorption for Cd(II) and Cu(II) from aqueous solutions. The effect of various parameters on adsorption process such as contact time, solution pH, amount of CHAP and initial concentration of metal ions was studied at room temperature to optimize the conditions for maximum adsorption. The results showed that the removal efficiency of Cd(II) and Cu(II) by CHAP could reach 94 and 93.17%, respectively, when the initial Cd(II) concentration 80 mg/L and Cu(II) 60 mg/L and the liquid/solid ratio was 2.5 g/L. The equilibrium sorption data for single metal systems at room temperature could be described by the Langmuir and Freundlich isotherm models. The highest value of Langmuir maximum uptake, (b), was found for cadmium (111.1 mg/g) and copper (142.86 mg/g). Similar Freundlich empirical constants, K, were obtained for cadmium (2.224) and copper (7.925). Ion exchange and surface adsorption might be involved in the adsorption process of cadmium and copper. Desorption experiments showed that CaCl 2 , NaCl, acetic acid and ultrasonic were not efficient enough to desorb substantial amount of metal ions from the CHAP. The results obtained show that CHAP has a high affinity to cadmium and copper

  8. [Facial injections of hyaluronic acid-based fillers for malformations. Preliminary study regarding scar tissue improvement and cosmetic betterment].

    Science.gov (United States)

    Franchi, G; Neiva-Vaz, C; Picard, A; Vazquez, M-P

    2018-02-02

    Cross-linked hyaluronic acid-based fillers have gained rapid acceptance for treating facial wrinkles, deep tissue folds and sunken areas due to aging. This study evaluates, in addition to space-filling properties, their effects on softness and elasticity as a secondary effect, following injection of 3 commercially available cross-linked hyaluronic acid-based fillers (15mg/mL, 17,5mg/mL and 20mg/mL) in patients presenting with congenital or acquired facial malformations. We started injecting gels of cross-linked hyaluronic acid-based fillers in those cases in 2013; we performed 46 sessions of injections in 32 patients, aged from 13-32. Clinical assessment was performed by the patient himself and by a plastic surgeon, 15 days after injections and 6-18 months later. Cross-linked hyaluronic acid-based fillers offered very subtle cosmetic results and supplemented surgery with a very high level of satisfaction of the patients. When injected in fibrosis, the first session enhanced softness and elasticity; the second session enhanced the volume. Cross-linked hyaluronic acid-based fillers fill sunken areas and better softness and elasticity of scar tissues. In addition to their well-understood space-filling function, as a secondary effect, the authors demonstrate that cross-linked hyaluronic acid-based fillers improve softness and elasticity of scarring tissues. Many experimental studies support our observations, showing that cross-linked hyaluronic acid stimulates the production of several extra-cellular matrix components, including dermal collagen and elastin. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  9. CT assisted follow-up of arthroscopically placed hydroxylapatite grafts in repair of fracture of the tibial head. Initial results of a CT assisted, quantitative assessment of the incorporation of the calcium hydroxylapatite graft and the reactions of the surrounding tissue

    International Nuclear Information System (INIS)

    Liebig, T.; Schedel, H.; Kodadadyan, Z.; Ricke, J.; Hoffmann, R.; Haas, N.; Felix, R.

    1996-01-01

    Four patients bearing a hydroxylapatite graft in repair of tibial head fracture have been examined by CT immediately after surgery and several times in the post operative period of up to 24 months. Density measurements of the graft, the spongiosa immediately next to it, and the spongiosa in fibula and tibia reveal the integration and ossous connection of the graft, quantifiable by the X-ray density. The spongiosa in immediate contact with the graft shows an initial density increase related to the first post-operative data, followed by a density decrease observed by subsequent measurements. These results are in agreement with animal experimental data and histomorphologic studies of other authors, which show that porous hydroxylapatite is used by the bone as a matrix serving as a pathway for osteoblast migration and subsequent ossification of the graft. Thus CT is capable of showing the post-operative integration process by quantifying and reproducible data. (orig.) [de

  10. Temporal fossa defects: techniques for injecting hyaluronic acid filler and complications after hyaluronic acid filler injection.

    Science.gov (United States)

    Juhász, Margit Lai Wun; Marmur, Ellen S

    2015-09-01

    Facial changes with aging include thinning of the epidermis, loss of skin elasticity, atrophy of muscle, and subcutaneous fat and bony changes, all which result in a loss of volume. As temporal bones become more concave, and the temporalis atrophies and the temporal fat pad decreases, volume loss leads to an undesirable, gaunt appearance. By altering the temporal fossa and upper face with hyaluronic acid filler, those whose specialty is injecting filler can achieve a balanced and more youthful facial structure. Many techniques have been described to inject filler into the fossa including a "fanned" pattern of injections, highly diluted filler injection, and the method we describe using a three-injection approach. Complications of filler in the temporal fossa include bruising, tenderness, swelling, Tyndall effect, overcorrection, and chewing discomfort. Although rare, more serious complications include infection, foreign body granuloma, intravascular necrosis, and blindness due to embolization into the ophthalmic artery. Using reversible hyaluronic acid fillers, hyaluronidase can be used to relieve any discomfort felt by the patient. Injectors must be aware of the complications that may occur and provide treatment readily to avoid morbidities associated with filler injection into this sensitive area. © 2015 Wiley Periodicals, Inc.

  11. Thermal Conductivity of Aluminosilicate- and Aluminum Oxide-Filled Thermosets for Injection Molding: Effect of Filler Content, Filler Size and Filler Geometry

    Directory of Open Access Journals (Sweden)

    Yang Zhao

    2018-04-01

    Full Text Available In this study, epoxy molding compounds (EMCs with aluminosilicate (AlS and aluminum oxide (AlO were fabricated as fillers by a twin-screw-extruder (TSE and shaped to plate samples using injection molding. AlS and AlO, electrical insulating mineral materials, were used as fillers to improve the thermal conductivity (λc of composites. Composites with different filler particle sizes, filler contents and filler geometry were fabricated and the influence of these variables on the λc was studied. The λc of composites was measured with the hot-disk method. The distribution of fillers in composites was observed using scanning electron microscopy (SEM. Using the Lewis-Nielsen equation, experimental values of λc were compared with those predicted. The predicted results fit the experimental values well. The result showed that λc increases significantly when the filler content of composites is approximately over 50 vol %.

  12. Modification of montmorillonite fillers by ionizing radiation

    International Nuclear Information System (INIS)

    Zimek, Z.; Przybytniak, G.; Nowicki, A.; Mirkowski, K.

    2006-01-01

    The mineral fillers can be modified by using unsaturated compounds: styrene, methacrylic acid and maleic anhydride (MA), following by irradiation with high energy electron beam. In presented paper the authors have used this method to change properties of bentonite S pecjal , containing about 70% of pure montmorillonite. It has been shown that: (a) the particles obtained in this process can be good fillers for the production of composites; (b) maleic anhydride reacts via anhydride group with active ionic sites of bentonite, forming a salt-like compound. Irradiation with electron beam leads to the breakage of double bond in maleic anhydride and to the production of new organic phases

  13. Thermal Properties of Asphalt Mixtures Modified with Conductive Fillers

    Directory of Open Access Journals (Sweden)

    Byong Chol Bai

    2015-01-01

    Full Text Available This paper investigates the thermal properties of asphalt mixtures modified with conductive fillers used for snow melting and solar harvesting pavements. Two different mixing processes were adopted to mold asphalt mixtures, dry- and wet-mixing, and two conductive fillers were used in this study, graphite and carbon black. The thermal conductivity was compared to investigate the effects of asphalt mixture preparing methods, the quantity, and the distribution of conductive filler on thermal properties. The combination of conductive filler with carbon fiber in asphalt mixture was evaluated. Also, rheological properties of modified asphalt binders with conductive fillers were measured using dynamic shear rheometer and bending beam rheometer at grade-specific temperatures. Based on rheological testing, the conductive fillers improve rutting resistance and decrease thermal cracking resistance. Thermal testing indicated that graphite and carbon black improve the thermal properties of asphalt mixes and the combined conductive fillers are more effective than the single filler.

  14. Waste-wood-derived fillers for plastics

    Science.gov (United States)

    Brent English; Craig M. Clemons; Nicole Stark; James P. Schneider

    1996-01-01

    Filled thermoplastic composites are stiffer, stronger, and more dimensionally stable than their unfilled counterparts. Such thermoplastics are usually provided to the end-user as a precompounded, pelletized feedstock. Typical reinforcing fillers are inorganic materials like talc or fiberglass, but materials derived from waste wood, such as wood flour and recycled paper...

  15. Nickel-chromium-silicon brazing filler metal

    Science.gov (United States)

    Martini, Angelo J.; Gourley, Bruce R.

    1976-01-01

    A brazing filler metal containing, by weight percent, 23-35% chromium, 9-12% silicon, a maximum of 0.15% carbon, and the remainder nickel. The maximum amount of elements other than those noted above is 1.00%.

  16. Intraoral approach: A newer technique for filler injection

    Directory of Open Access Journals (Sweden)

    Chytra V Anand

    2010-01-01

    Full Text Available Filler injections are the most common aesthetic procedures used for volume correction. Various techniques have been described in the use of fillers. This article reviews the available literature on a new technique using the intraoral approach for injection of fillers.

  17. Species Typing in Dermal Leishmaniasis

    Science.gov (United States)

    Dujardin, Jean-Claude

    2015-01-01

    SUMMARY Leishmania is an infectious protozoan parasite related to African and American trypanosomes. All Leishmania species that are pathogenic to humans can cause dermal disease. When one is confronted with cutaneous leishmaniasis, identification of the causative species is relevant in both clinical and epidemiological studies, case management, and control. This review gives an overview of the currently existing and most used assays for species discrimination, with a critical appraisal of the limitations of each technique. The consensus taxonomy for the genus is outlined, including debatable species designations. Finally, a numerical literature analysis is presented that describes which methods are most used in various countries and regions in the world, and for which purposes. PMID:25672782

  18. Bioactive glass particulate filler composite: Effect of coupling of fillers and filler loading on some physical properties.

    Science.gov (United States)

    Oral, Onur; Lassila, Lippo V; Kumbuloglu, Ovul; Vallittu, Pekka K

    2014-05-01

    The aim of this study was to investigate the effect of silanization of biostable and bioactive glass fillers in a polymer matrix on some of the physical properties of the composite. The water absorption, solubility, flexural strength, flexural modulus and toughness of different particulate filler composite resins were studied in vitro. Five different specimen groups were analyzed: A glass-free control, a non-silanized bioactive glass, a silanized bioactive glass, a non-silanized biostable glass and a silanized biostable glass groups. All of these five groups were further divided into sub-groups of dry and water-stored materials, both of them containing groups with 3wt%, 6wt%, 9wt% or 12wt% of glass particles (n=8 per group). The silanization of the glass particles was carried out with 2% of gamma-3-methacryloxyproyltrimethoxysilane (MPS). For the water absorption and solubility tests, the test specimens were stored in water for 60 days, and the percentages of weight change were statistically analyzed. Flexural strength, flexural modulus and toughness values were tested with a three-point bending test and statistically analyzed. Higher solubility values were observed in non-silanized glass in proportion to the percentage of glass particles. Silanization, on the other hand, decreased the solubility values of both types of glass particles and polymer. While 12wt% non-silanized bioactive glass specimens showed -0.98wt% solubility, 12wt% silanized biostable glass specimens were observed to have only -0.34wt% solubility. The three-point bending results of the dry specimens showed that flexural strength, toughness and flexural modulus decreased in proportion to the increase of glass fillers. The control group presented the highest results (106.6MPa for flexural strength, 335.7kPA for toughness, 3.23GPa for flexural modulus), whereas for flexural strength and toughness, 12wt% of non-silanized biostable glass filler groups presented the lowest (70.3MPa for flexural strength

  19. Tetrabromobisphenol A In vitro Dermal Absopriton Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — In vitro dermal absorption data of tetrabromobisphenol A using human cadaver and rat skin. This dataset is associated with the following publication: Knudsen, G., M....

  20. The evolving role of hyaluronic acid fillers for facial volume restoration and contouring: a Canadian overview

    Directory of Open Access Journals (Sweden)

    Muhn C

    2012-10-01

    Full Text Available Channy Muhn,1 Nathan Rosen,1 Nowell Solish,2 Vince Bertucci,2 Mark Lupin,3 Alain Dansereau,4 Fred Weksberg,5 B Kent Remington,6 Arthur Swift71Division of Dermatology, McMaster University, Hamilton, Ontario, 2Division of Dermatology, New Women's College Hospital, Toronto, Ontario, 3Department of Dermatology and Skin Science, University of British Columbia, Vancouver, British Columbia, 4Private Practice, Repentigny, Québec, 5Department of Medicine, University of Toronto, Toronto, Ontario, 6Private Practice, Calgary, Alberta, Canada; 7St Mary's Hospital, McGill University, Montréal, Québec, CanadaAbstract: Recent advancements, including more versatile facial fillers, refined injection techniques and the adoption of a global facial approach, have contributed to improved patient outcome and increased patient satisfaction. Nine Canadian specialists (eight dermatologists, one plastic surgeon collaborated to develop an overview on volume restoration and contouring based on published literature and their collective clinical experience. The specialists concurred that optimal results in volume restoration and contouring depend on correcting deficiencies at various layers of the facial envelope. This includes creating a foundation for deep structural support in the supraperiosteal or submuscular plane; volume repletion of subcutaneous fat compartments; and the reestablishment of dermal and subdermal support to minimize cutaneous rhytids, grooves and furrows. It was also agreed that volume restoration and contouring using a global facial approach is essential to create a natural, youthful appearance in facial aesthetics. A comprehensive non-surgical approach should therefore incorporate combining fillers such as high-viscosity, low-molecular-weight hyaluronic acid (LMWHA for structural support and hyaluronic acid (HA for lines, grooves and furrows with neuromodulators, lasers and energy devices.Keywords: hyaluronic acid filler, volumizing, facial

  1. Flexible Dermal Armor : Designs Learned from Nature

    OpenAIRE

    Chen, Irene Hsu

    2015-01-01

    Designs derived from nature have become a perfect blueprint for today's engineers and scientists to follow and implement. One particularly noted area is the defense industry, wherein flexible dermal armor inspired by nature has been pioneering many sophisticated technologies and designs in recent years. Designers today are considering borrowing aspects of flexibility and mobility of natural dermal armors to enhance the maneuverability of man-made armor by imitating the following mechanisms : ...

  2. Mechanical properties and filler distribution as a function filler content in silica filled PDMS samples

    International Nuclear Information System (INIS)

    Hawley, Marilyn E.; Wrobleski, Debra A.; Orler, E. Bruce; Houlton, Robert J.; Chitanvis, Kiran E.; Brown, Geoffrey W.; Hanson, David E.

    2004-01-01

    Atomic force microscopy (AFM) phase imaging and tensile stress-strain measurements are used to study a series of model compression molded fumed silica filled polydimethysiloxane (PDMS) samples with filler content of zero, 20, 35, and 50 parts per hundred (phr) to determine the relationship between filler content and stress-strain properties. AFM phase imaging was used to determine filler size, degree of aggregation, and distribution within the soft PDMS matrix. A small tensile stage was used to measure mechanical properties. Samples were not pulled to break in order to study Mullins and aging effects. Several identical 35 phr samples were subjected to an initial stress, and then one each was reevaluated over intervals up to 26 weeks to determine the degree to which these samples recovered their initial stress-strain behavior as a function of time. One sample was tested before and after heat treatment to determine if heating accelerated recovery of the stress-strain behavior. The effect of filler surface treatment on mechanical properties was examined for two samples containing 35 phr filler treated or untreated with hexamethyldisilazane (HMDZ), respectively. Fiduciary marks were used on several samples to determine permanent set. 35 phr filler samples were found to give the optimum mechanical properties. A clear Mullins effect was seen. Within experimental error, no change was seen in mechanical behavior as a function of time or heat-treatment. The mechanical properties of the sample containing the HDMZ treated silica were adversely affected. AFM phase images revealed aggregation and nonuniform distribution of the filler for all samples. Finally, a permanent set of about 3 to 6 percent was observed for the 35 phr samples.

  3. [Advantages of combined therapies in cosmetic medicine for the treatment of face aging: botulinum toxin, fillers and mesotherapy].

    Science.gov (United States)

    Braccini, F; Dohan Ehrenfest, D M

    2010-01-01

    Non surgical cosmetic medicine procedures for the face are developing considerably, as they deliver good results using simple, non invasive, atraumatic and reproducible techniques. Aesthetic mesotherapy, also known as anti-aging mesotherapy, uses intra-dermal injections of a nutritive and moisturizing solution to improve brightness, skin hydration and tonus, and also smooth out superficial wrinkles. Subcutaneous filler injections enable to fill wrinkles and folds; by using high density products it is also able to provide genuine facial volumetric reconstruction. Finally, botulinum toxin acts by reducing certain muscle contractions to smooth out expression lines and folds induced by facial dynamics. In this article, we explore the concept of combined therapy and describe our experience associating anti-aging mesotherapy (NCTF-135HA, Filorga, Paris, France), hyaluronic acid based fillers (X-HA3 and X-HA-Volume, Filorga, Paris, France) and botulinum toxin (Vistabel, Allergan, Irvine CA, USA). A therapy combining anti-aging mesotherapy, botulinum toxin and filler injections, offers full treatment of the 3 biological levels of the covering tissues. This non-invasive therapeutic strategy brings patient satisfaction through a global approach to facial aging.

  4. Use of a biopolymer polyalkylimide filler for facial lipodystrophy in HIV-positive patients undergoing treatment with antiretroviral drugs.

    Science.gov (United States)

    Treacy, Patrick J; Goldberg, David J

    2006-06-01

    To evaluate the efficacy, overall esthetic effect, and safety of a new permanent, polyalkylimide dermal filler in HIV-infected patients with severe facial lipodystrophy. Eleven subjects with severe facial lipodystrophy secondary to HIV infection were injected bilaterally with 15 and 30 cm3 of a polyalkylimide gel into the buccal, malar, and temporal areas of the face in an attempt to restore their facial contour. The youngest treated subject was 31 years of age and the oldest 73 years of age. All 11 subjects received an immediately acceptable therapeutic esthetic effect. Injections were generally well tolerated, with only three adverse events (swelling and bruising) recorded. Subjects, assessed at 3 and 18 months after treatment, continued to show improvement. The immediate benefits of a polyalkylimide gel in the correction and restoration of facial contour in subjects having severe HIV-related facial lipodystrophy were demonstrated. This improvement was still noted at 18 months. The efficacy, ease of injection, and safety profile of polyalkylimide gel make this filling material a potentially attractive treatment for lipodystrophy. These data must be tempered with the need for significant further safety studies to determine whether this long-term filler has a safety profile consistent with other currently popular fillers.

  5. PROCESS TIME OPTIMIZATION IN DEPOSITOR AND FILLER

    Directory of Open Access Journals (Sweden)

    Jesús Iván Ruíz-Ibarra

    2017-07-01

    Full Text Available As in any industry, in soft drink manufacturing demand, customer service and production is of great importance that forces this production to have their equipment and production machines in optimal conditions for the product to be in the hands of the consumer without delays, therefore it is important to have the established times of each process, since the syrup is elaborated, packaged, distributed, until it is purchased by the consumer. After a chronometer analysis, the most common faults were detected in each analyzed process. In the filler machine the most frequent faults are: accumulation of bottles in the subsequent and previous processes to filling process, which in general the cause of the collection of bottles is due to failures in the other equipment of the production line. In the process of unloading the most common faults are: boxes jammed in bump and pusher (pushing boxes; boxes fallen in rollers and platforms transporter. According to observations in each machine, the actions to be followed are presented to solve the problems that arise. Also described the methodology to obtain results, to data analyze and decisions. Firstly an analysis of operations is done to know each machine, supported by the manuals of the machines and the operators themselves a study of times is done by chronometer to determine the standard time of the process where also they present the most common faults, then observations are made on the machines according to the determined sample size, thus obtaining the information necessary to take measurements and to make the study of optimization of the production processes. An analysis of the predetermined process times is also performed by the MTM methods and the MOST time analysis. The results of operators with MTM: Fault Filler = 0.846 minutes, Faultless Filler = 0.61 minutes, Fault Breaker = 0.74 minutes and Fault Flasher = 0.45 minutes. The results of MOST operators are: Fault Filler = 2.58 minutes, Filler Fails

  6. Filler migration and extensive lesions after lip augmentation: Adverse effects of polydimethylsiloxane filler.

    Science.gov (United States)

    Abtahi-Naeini, Bahareh; Faghihi, Gita; Shahmoradi, Zabihollah; Saffaei, Ali

    2018-01-07

    Polydimethylsiloxane (PDMS), also called liquid silicone, belongs to a group of polymeric compounds that are commonly referred to as silicones. These filling agents have been used as injectable filler for soft tissue augmentation. There are limited experiences about management of the severe complications related to filler migration associated with PDMS injection. We present a 35-year-old female with severe erythema, edema over her cheeks and neck, and multiple irregularities following cosmetic lip augmentation with PDMS. Further studies are required for management of this complicated case of PDMS injection. © 2018 Wiley Periodicals, Inc.

  7. Inductive capacity of irradiated dermal papillae

    International Nuclear Information System (INIS)

    Ibrahim, L.; Wright, E.A.

    1977-01-01

    It is stated that the importance of the dermal papilla for the maintenance and control of hair cycles in mammals has long been recognised, but there has been little direct evidence of its mode of functioning. Permanent removal of rat body hair has resulted from large doses of X-radiation and it was believed that this caused destruction of the dermal papilla, which in turn resulted in permanent epilation. A study is here reported on the effect of heavy doses of irradiation on the dermal papilla and epithelial elements of the hair follicles of mice and rats. It was found that the high doses that caused permanent epilation destroyed the epithelium but left the dermal papilla anatomically and functionally intact, so that even on transplantation it could induce a series of new hairs. The dose employed was 2500 R of X-radiation for mice or 5000 R for rats. Hairs after transplantation were shorter than normal and had a slower rate of growth; depending on the size of the transplanted dermal papilla. The hairs become shorter with successive cycles of irradiation. (U.K.)

  8. Ultrasound detection and identification of cosmetic fillers in the skin

    DEFF Research Database (Denmark)

    Wortsman, X.; Wortsman, J.; Orlandi, C.

    2012-01-01

    Background While the incidence of cosmetic filler injections is rising world-wide, neither exact details of the procedure nor the agent used are always reported or remembered by the patients. Thus, although complications are reportedly rare, availability of a precise diagnostic tool to detect...... cutaneous filler deposits could help clarify the association between the procedure and the underlying pathology. Objectives The aim of this study was to evaluate cutaneous sonography in the detection and identification of cosmetic fillers deposits and, describe dermatological abnormalities found associated...... with the presence of those agents. Methods We used ultrasound in a porcine skin model to determine the sonographic characteristics of commonly available filler agents, and subsequently applied the analysis to detect and identify cosmetic fillers among patients referred for skin disorders. Results Fillers...

  9. Induction and removal of DNA interstrand cross-links in V-79 Chinese hamster cells measured by hydroxylapatite chromatography after treatments with bifunctional furocoumarins

    International Nuclear Information System (INIS)

    Dardalhon, M.; Averbeck, D.

    1988-01-01

    DNA interstrand crosslinks (CL) photoinduced by bifunctional furocoumarins in V-79 Chinese hamster cells were measured by alkaline denaturation and hydroxylapatite chromatography. Treatments with 5-methoxypsoralen (5-MOP), 8-methoxypsoralen (8-MOP) and 4,5',8-trimethylpsoralen (4,5',8-TMP) and 365 nm irradiation (UVA) confer a dose-dependent linear increase in the amount of double-stranded DNA indicating the induction of CL. Determination in alkaline sucrose gradients of the molecular weight of the DNA and estimation of drug-induced strand breakage allowed quantification of the CL induced. 5-MOP was found to be slightly more effective than 8-MOP whereas 4,5',8-TMP was 9 times more effective for the induction of CL. The fate of CL during post-treatment incubation was also followed. Cells in exponential growth phase were found to be efficient in the removal of CL. (Author)

  10. Filler metal alloy for welding cast nickel aluminide alloys

    Science.gov (United States)

    Santella, M.L.; Sikka, V.K.

    1998-03-10

    A filler metal alloy used as a filler for welding cast nickel aluminide alloys contains from about 15 to about 17 wt. % chromium, from about 4 to about 5 wt. % aluminum, equal to or less than about 1.5 wt. % molybdenum, from about 1 to about 4.5 wt. % zirconium, equal to or less than about 0.01 wt. % yttrium, equal to or less than about 0.01 wt. % boron and the balance nickel. The filler metal alloy is made by melting and casting techniques such as are melting the components of the filler metal alloy and cast in copper chill molds. 3 figs.

  11. rice husk as filler rice husk as filler in the production of bricks using

    African Journals Online (AJOL)

    eobe

    block [1].The effect of palm fruit fibre in clay bricks was also investigated by Akinyele and Abdulraheem,. [2], they observed ... the Rice Husk ash at 8% improves the compressive ... that 5% mix of the material acts as a filler in concrete because ...

  12. Evaluation of Different Mineral Filler Aggregates for Asphalt Mixtures

    Science.gov (United States)

    Wasilewska, Marta; Małaszkiewicz, Dorota; Ignatiuk, Natalia

    2017-10-01

    Mineral filler aggregates play an important role in asphalt mixtures because they fill voids in paving mix and improve the cohesion of asphalt binder. Limestone powder containing over 90% of CaCO3 is the most frequently used type of filler. Waste material from the production of coarse aggregate can be successfully used as a mineral filler aggregate for hot asphalt concrete mixtures as the limestone powder replacement. This paper presents the experimental results of selected properties of filler aggregates which were obtained from rocks with different mineral composition and origin. Five types of rocks were used as a source of the mineral filler aggregate: granite, gabbro, trachybasalt, quartz sandstone and rocks from postglacial deposits. Limestone filler was used in this study as the reference material. The following tests were performed: grading (air jet sieving), quality of fines according to methylene blue test, water content by drying in a ventilated oven, particle density using pyknometer method, Delta ring and ball test, Bitumen Number, fineness determined as Blaine specific surface area. Mineral filler aggregates showed significant differences when they were mixed with bitumen and stiffening effect in Delta ring and ball test was evaluated. The highest values were achieved when gabbro and granite fillers were used. Additionally, Scanning Electron Microscopy (SEM) analysis of grain shape and size was carried out. Significant differences in grain size and shape were observed. The highest non-homogeneity in size was determined for quartz sandstone, gabbro and granite filler. Their Blaine specific surface area was lower than 2800 cm2/g, while for limestone and postglacial fillers with regular and round grains it exceeded 3000 cm2/g. All examined mineral filler aggregates met requirements of Polish National Specification WT-1: 2014 and could be used in asphalt mixtures.

  13. 7 CFR 58.229 - Filler and packaging equipment.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Filler and packaging equipment. 58.229 Section 58.229....229 Filler and packaging equipment. All filling and packaging equipment shall be of sanitary... equipment should comply with the 3-A Sanitary Standards for equipment for Packaging Dry Milk and Dry Milk...

  14. High filler concrete using fly ash. Chloride penetration and microstructure

    NARCIS (Netherlands)

    Valcke, S.L.A.; Polder, R.B.; Nijland, T.G.; Leegwater, G.A.; Visser, J.H.M.; Bigaj-van Vliet, A.J.

    2012-01-01

    Most high filler concrete studies are based on relatively high contents of powder (cement + filler) (>400 kg m-3). This paper aims to increase the total fly ash content relative to the clinker content, while simultaneously minimizing the total powder content in the concrete to values lower than 300

  15. High filler concrete using fly ash : Chloride penetration and microstructure

    NARCIS (Netherlands)

    Valcke, S.L.A.; Polder, R.B.; Nijland, T.G.; Leegwater, G.A.; Visser, J.H.M.; Bigaj-van Vliet, A.J.

    2012-01-01

    Most high filler concrete studies are based on relatively high contents of powder (cement + filler) (>400 kg m-3). This paper aims to increase the total fly ash content relative to the clinker content, while simultaneously minimizing the total powder content in the concrete to values lower than 300

  16. Flame Retardant Effect of Nano Fillers on Polydimethylsiloxane Composites.

    Science.gov (United States)

    Jagdale, Pravin; Salimpour, Samera; Islam, Md Hujjatul; Cuttica, Fabio; Hernandez, Francisco C Robles; Tagliaferro, Alberto; Frache, Alberto

    2018-02-01

    Polydimethylsiloxane has exceptional fire retardancy characteristics, which make it a popular polymer in flame retardancy applications. Flame retardancy of polydimethylsiloxane with different nano fillers was studied. Polydimethylsiloxane composite fire property varies because of the shape, size, density, and chemical nature of nano fillers. In house made carbon and bismuth oxide nano fillers were used in polydimethylsiloxane composite. Carbon from biochar (carbonised bamboo) and a carbon by-product (carbon soot) were selected. For comparative study of nano fillers, standard commercial multiwall carbon nano tubes (functionalised, graphitised and pristine) as nano fillers were selected. Nano fillers in polydimethylsiloxane positively affects their fire retardant properties such as total smoke release, peak heat release rate, and time to ignition. Charring and surface ceramization are the main reasons for such improvement. Nano fillers in polydimethylsiloxane may affect the thermal mobility of polymer chains, which can directly affect the time to ignition. The study concludes that the addition of pristine multiwall carbon nano tubes and bismuth oxide nano particles as filler in polydimethylsiloxane composite improves the fire retardant property.

  17. Effect of different carbon fillers and dopant acids on electrical ...

    Indian Academy of Sciences (India)

    The nature of both the carbon filler and the dopant acid can significantly influence the conductivity of these nanocomposites. This paper describes the effects of carbon fillers like carbon black (CB), graphite (GR) and muti-walled carbon nanotubes (MWCNT) and of dopant acids like methane sulfonic acid (MSA), camphor ...

  18. 14 CFR 25.973 - Fuel tank filler connection.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel tank filler connection. 25.973 Section 25.973 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.973 Fuel tank filler...

  19. 14 CFR 27.973 - Fuel tank filler connection.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel tank filler connection. 27.973 Section 27.973 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.973 Fuel tank filler connection...

  20. 14 CFR 29.973 - Fuel tank filler connection.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel tank filler connection. 29.973 Section 29.973 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.973 Fuel tank filler...

  1. Selecting fillers on emotional appearance improves lineup identification accuracy.

    Science.gov (United States)

    Flowe, Heather D; Klatt, Thimna; Colloff, Melissa F

    2014-12-01

    Mock witnesses sometimes report using criminal stereotypes to identify a face from a lineup, a tendency known as criminal face bias. Faces are perceived as criminal-looking if they appear angry. We tested whether matching the emotional appearance of the fillers to an angry suspect can reduce criminal face bias. In Study 1, mock witnesses (n = 226) viewed lineups in which the suspect had an angry, happy, or neutral expression, and we varied whether the fillers matched the expression. An additional group of participants (n = 59) rated the faces on criminal and emotional appearance. As predicted, mock witnesses tended to identify suspects who appeared angrier and more criminal-looking than the fillers. This tendency was reduced when the lineup fillers matched the emotional appearance of the suspect. Study 2 extended the results, testing whether the emotional appearance of the suspect and fillers affects recognition memory. Participants (n = 1,983) studied faces and took a lineup test in which the emotional appearance of the target and fillers was varied between subjects. Discrimination accuracy was enhanced when the fillers matched an angry target's emotional appearance. We conclude that lineup member emotional appearance plays a critical role in the psychology of lineup identification. The fillers should match an angry suspect's emotional appearance to improve lineup identification accuracy. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  2. Bio-based fillers for environmentally friendly composites

    CSIR Research Space (South Africa)

    Mokhothu, Thabang H

    2017-03-01

    Full Text Available The use of bio-based fillers as alternative replacement for synthetic fillers has been dictated by increasing ecological concerns as well as depleting petroleum resources. The other aspect is a growing need for eco-friendly, renewable...

  3. Biocomposites from polyhydroxybutyrate and bio-fillers by solvent ...

    Indian Academy of Sciences (India)

    Biocomposites from polyhydroxybutyrate (PHB) and some bio-fillers such as lignin (L), alpha cellulose (AC) and cellulose nanofibrils (CNFs) were prepared to investigate the effect of the bio-fillers on the properties of PHB by a solvent casting method. The thermal properties by thermogravimetry analysis (TGA–DTG and ...

  4. Assessment of dermal exposure to chemicals

    NARCIS (Netherlands)

    Hemmen, J.J. van; Brouwer, D.H.

    1995-01-01

    The methods for the dermal exposure assessment vary in their complexity and are in some sense complementary to each other. The most easy-to-use methods involve a pseudo-skin-approach, such as gloves and removal by washing. In some cases generic modelling appears to be possible. The experimental

  5. A Dermal Piercing Complicated by Mycobacterium fortuitum

    Science.gov (United States)

    Scroggins-Markle, Leslie; Kelly, Brent

    2013-01-01

    Background. Dermal piercings have recently become a fashion symbol. Common complications include hypertrophic scarring, rejection, local infection, contact allergy, and traumatic tearing. We report a rare case of Mycobacterium fortuitum following a dermal piercing and discuss its medical implications and treatments. Case. A previously healthy 19-year-old woman presented complaining of erythema and edema at the site of a dermal piercing on the right fourth dorsal finger. She was treated with a 10-day course of trimethoprim-sulfamethoxazole and one course of cephalexin by her primary care physician with incomplete resolution. The patient stated that she had been swimming at a local water park daily. A punch biopsy around the dermal stud was performed, and cultures with sensitivities revealed Mycobacterium fortuitum. The patient was treated with clarithromycin and ciprofloxacin for two months receiving full resolution. Discussion. Mycobacterium fortuitum is an infrequent human pathogen. This organism is a Runyon group IV, rapidly growing nontuberculous mycobacteria, often found in water,soil, and dust. Treatment options vary due to the size of the lesion. Small lesions are typically excised, while larger lesions require treatment for 2–6 months with antibiotics. We recommend a high level of suspicion for atypical mycobacterial infections in a piercing resistant to other therapies. PMID:24073343

  6. A Dermal Piercing Complicated by Mycobacterium fortuitum

    Directory of Open Access Journals (Sweden)

    Trisha Patel

    2013-01-01

    Full Text Available Background. Dermal piercings have recently become a fashion symbol. Common complications include hypertrophic scarring, rejection, local infection, contact allergy, and traumatic tearing. We report a rare case of Mycobacterium fortuitum following a dermal piercing and discuss its medical implications and treatments. Case. A previously healthy 19-year-old woman presented complaining of erythema and edema at the site of a dermal piercing on the right fourth dorsal finger. She was treated with a 10-day course of trimethoprim-sulfamethoxazole and one course of cephalexin by her primary care physician with incomplete resolution. The patient stated that she had been swimming at a local water park daily. A punch biopsy around the dermal stud was performed, and cultures with sensitivities revealed Mycobacterium fortuitum. The patient was treated with clarithromycin and ciprofloxacin for two months receiving full resolution. Discussion. Mycobacterium fortuitum is an infrequent human pathogen. This organism is a Runyon group IV, rapidly growing nontuberculous mycobacteria, often found in water,soil, and dust. Treatment options vary due to the size of the lesion. Small lesions are typically excised, while larger lesions require treatment for 2–6 months with antibiotics. We recommend a high level of suspicion for atypical mycobacterial infections in a piercing resistant to other therapies.

  7. Focal dermal hypoplasia: A rare case report

    Directory of Open Access Journals (Sweden)

    Sahana M Srinivas

    2015-01-01

    Full Text Available Focal dermal hypoplasia (Goltz syndrome is a rare genetic multisystem disorder primarily involving the skin, skeletal system, eyes, and face. We report the case of an eight-month-old female child who presented with multiple hypopigmented atrophic macules along the lines of blaschko, skeletal anomalies, umbilical hernia, developmental delay, hypoplastic nails, syndactyly, and lobster claw deformity characteristic of Goltz syndrome.

  8. The development of brazing filler for ITER thermal anchor attachment

    International Nuclear Information System (INIS)

    Lee, P.Y.; Sun, Z.C.; Pan, C.J.; Hou, B.L.; Han, S.L.; Pei, Y.Y.; Long, W.M.

    2011-01-01

    Magnet supports is one of the key components to sustain the ITER superconductor magnet coils, which operate at several K low temperature. Cooling of the supports is needed for maintaining temperature balance. It is suggested to use brazing connection to attach the thermal anchor to the support which made from SS 316LN plates. In this study, several kinds of brazing filler were developed as candidates, including Sn-Pb brazing filler, Ag-based and Cu-based brazing filler. The test result shows that Ag-based brazing filler has the best weldability with 316LN, but Cu-based alloy shows the best mechanical properties at both room temperature and 77 K. Even though the Sn-Pb alloy shows the lowest strength, it can be easily brazed due to the low brazing temperature. Detail of the brazing filler selection is suggested and discussed in this article.

  9. Managing complications of fillers: Rare and not-so-rare

    Directory of Open Access Journals (Sweden)

    Eckart Haneke

    2015-01-01

    Full Text Available Fillers belong to the most frequently used beautifying products. They are generally well tolerated, but any one of them may occasionally produce adverse side effects. Adverse effects usually last as long as the filler is in the skin, which means that short-lived fillers have short-term side effects and permanent fillers may induce life-long adverse effects. The main goal is to prevent them, however, this is not always possible. Utmost care has to be given to the prevention of infections and the injection technique has to be perfect. Treatment of adverse effects is often with hyaluronidase or steroid injections and in some cases together with 5-fluorouracil plus allopurinol orally. Histological examination of biopsy specimens often helps to identify the responsible filler allowing a specific treatment to be adapted.

  10. Midface swelling reveals nasofrontal dermal sinus

    International Nuclear Information System (INIS)

    Houneida, Zaghouani Ben Alaya; Manel, Limeme; Latifa, Harzallah; Habib, Amara; Dejla, Bakir; Chekib, Kraiem

    2012-01-01

    Nasofrontal dermal sinuses are very rare and generally occur in children. This congenital malformation can be revealed by midface swelling, which can be complicated by local infection or neuromeningitis. Such complications make the dermal sinus a life-threatening disease. Two cases of nasofrontal dermal sinuses are reported in this work. The first case is an 11-month-old girl who presented with left orbitonasal soft tissue swelling accompanied by inflammation. Physical examination found fever, left orbitonasal thickening, and a puncture hole letting out pus. Computed tomography revealed microabscesses located at the left orbitonasal soft tissues, a frontal bone defect, and an intracranial cyst. Magnetic resonance imaging showed the transosseous tract between the glabella and the brain and affirmed the epidermoid nature of the intracranial cyst. The second case is a 7-year-old girl who presented with a nasofrontal non-progressive mass that intermittently secreted a yellow liquid through an external orifice located at the glabella. MRI revealed a cystic mass located in the deep layer of the glabellar skin related to an epidermoid cyst with a nasofrontal dermal sinus tract. In both cases, surgical excision was performed, and pathological confirmation was made for the diagnoses of dermal sinuses. The postoperative course was favorable. Through these cases, the authors stress the role of imaging methods in confirming the diagnosis and looking for associated cysts (dermoid and epidermoid) to improve recognition of this rare disease. Knowledge of the typical clinical presentations, imaging manifestations, and most common sites of occurrence of this malformation are needed to formulate a differential diagnosis.

  11. Mechanical properties of epoxy/coconut shell filler particle composites

    International Nuclear Information System (INIS)

    Sapuan, S.M.; Harimi, M.; Maleque, M.A.

    2003-01-01

    This paper presents the tensile and flexural properties of composites made from coconut shell filler particles and epoxy resin. The tensile and flexural tests of composites based on coconut shell filler particles at three different filler contents viz., 5%, 0% and 15%were carried out using universal tensile testing machine according to ASTM D 3039/D M-95a and ASTM D790-90 tensile respectively and their results were presented. Experimental results showed that tensile and flexural properties of the composites increased with the increase of the filler particle content. The composite materials demonstrate somewhat linear behavior and sharp structure for tensile and slight nonlinear behavior and sharp fracture of flexural testing. The relation between stress and percentage of filler for tensile and flexural tests were found to b linear with correlation factors of 0.9929 and 0.9973 respectively. Concerning the relation between the modulus and percentage of filler for tensile and flexural tests, it was found to be a quadratic relation with the same correlation factor approximated to 1. The same behavior was observed for the strain versus percentage of filler tensile and flexural tests, with the same correlation factor. (author)

  12. Microstructural and rheological analysis of fillers and asphalt mastics

    International Nuclear Information System (INIS)

    Geber, R; Simon, A; Kocserha, I; Buzimov, A

    2017-01-01

    Pavements are made of different grades of mineral aggregates and organic binder. The aggregates are sorted in different sizes and different amount which are mixed together with bitumen. The finest mineral fraction (d<0.063 mm) is called filler. This component has an important role in asphalt mixture - it fills the gaps between the aggregates and if mixed with bitumen (which is called asphalt mastics) it sticks the larger particles together. Particle size, microstructure and surface properties of fillers highly affect the cohesion with bitumen, therefore the aim of our research was to investigate the microstructure of mineral fillers (limestone, dolomite) which are used in Hungarian road constructions with the use of different techniques (particle size distribution, scanning electronmicroscopy tests, mercury intrusion porosimetry, BET specific surface tests, determination of hydrophobicity). After the tests of fillers, asphalt mastics were prepared and rheological examinations were obtained. These examinations served to observe the interaction and the effect of fillers. The stiffening effect of fillers and the causes of rutting were also investigated. Based on our results, it can be stated that particle size, hydrophobic properties and the amount of fillers highly affect the rheological properties of mastics. (paper)

  13. Hyaluronic acid fillers with cohesive polydensified matrix for soft-tissue augmentation and rejuvenation: a literature review

    Directory of Open Access Journals (Sweden)

    Prasetyo AD

    2016-09-01

    temporary. There were no reports of Tyndall effect, nodules, granulomas, or tissue necrosis.Conclusion: Clinical evidence indicates sustainable esthetic effects, good safety profile, and long-term tolerability of the Belotero® fillers, particularly Belotero® Basic/Balance and Intense. Keywords: CPM®, dermal filler, facial lines, filling, nasolabial fold, wrinkle

  14. The filler powders laser welding of ODS ferritic steels

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Shenyong, E-mail: s_y_liang@126.com; Lei, Yucheng; Zhu, Qiang

    2015-01-15

    Laser welding was performed on Oxide Dispersion Strengthened (ODS) ferritic steel with the self-designed filler powders. The filler powders were added to weld metal to produce nano-particles (Y–M–O and TiC), submicron particles (Y–M–O) and dislocation rings. The generated particles were evenly distributed in the weld metal and their forming mechanism and behavior were analyzed. The results of the tests showed that the nano-particles, submicron particles and dislocation rings were able to improve the micro-hardness and tensile strength of welded joint, and the filler powders laser welding was an effective welding method of ODS ferritic steel.

  15. Dissolving microneedle patches for dermal vaccination

    OpenAIRE

    Leone, M.; Monkare, J.T.; Bouwstra, J.A.; Kersten, G.F.A.

    2017-01-01

    The dermal route is an attractive route for vaccine delivery due to the easy skin accessibility and a dense network of immune cells in the skin. The development of microneedles is crucial to take advantage of the skin immunization and simultaneously to overcome problems related to vaccination by conventional needles (e.g. pain, needle-stick injuries or needle re-use). This review focuses on dissolving microneedles that after penetration into the skin dissolve releasing the encapsulated antige...

  16. Dermal fillers for the treatment of tear trough deformity: A review of anatomy, treatment techniques, and their outcomes

    Directory of Open Access Journals (Sweden)

    Jaishree Sharad

    2012-01-01

    Full Text Available Tear trough deformity is a major concern in a lot of individuals seeking periorbital rejuvenation. A prominent tear trough deformity is characterised by a sunken appearance of the eye that results in the casting of a dark shadow over the lower eyelid, giving the patient a fatigued appearance despite adequate rest, and is refractory to attempts at cosmetic concealment. The tear trough deformity is a natural consequence of the anatomic attachments of the periorbital tissues. A variety of techniques have evolved to address this cosmetic issue. Traditional techniques relied on surgical excision of skin, muscle, and fat as well as chemical peels. Treatment is now tailored towards specific anatomic abnormalities and often employs multiple modalities including surgery, botulinum toxin, and replacement of volume. Various original research articles, text book publications and review articles were studied. Data specific to the historical aspect and anatomy of tear trough have been enumerated. Techniques of different authors were analysed and their results and complications have been summarised. The technique of the author has also been described here.

  17. Dermal pocketing following distal finger replantation.

    Science.gov (United States)

    Puhaindran, Mark E; Paavilainen, Pasi; Tan, David M K; Peng, Yeong Pin; Lim, Aymeric Y T

    2010-08-01

    Replantation is an ideal technique for reconstruction following fingertip amputation as it provides 'like for like' total reconstruction of the nail complex, bone pulp tissue and skin with no donor-site morbidity. However, fingertips are often not replanted because veins cannot be found or are thought to be too small to repair. Attempts at 'cap-plasty' or pocketing of replanted tips with and without microvascular anastomosis have been done in the past with varying degrees of success. We prospectively followed up a group of patients who underwent digital replantation and dermal pocketing in the palm to evaluate the outcome of this procedure. There were 10 patients with 14 amputated digits (two thumbs, five index, four middle, two ring and one little) who underwent dermal pocketing of the amputated digit following replantation. Among the 14 digits that were treated with dermal pocketing, 11 survived completely, one had partial atrophy and two were completely lost. Complications encountered included finger stiffness (two patients) and infection of the replanted fingertip with osteomyelitis of the distal phalanx (one patient). We believe that this technique can help increase the chance of survival for distal replantation with an acceptable salvage rate of 85% in our series. Copyright 2009 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. Spectroscopic analyses on sonocatalytic damage to bovine serum albumin (BSA) induced by ZnO/hydroxylapatite (ZnO/HA) composite under ultrasonic irradiation

    Science.gov (United States)

    Wang, Zhiqiu; Li, Ying; Wang, Jun; Zou, Mingming; Gao, Jingqun; Kong, Yumei; Li, Kai; Han, Guangxi

    ZnO/hydroxylapatite (ZnO/HA) composite with HA molar content of 6.0% was prepared by the method of precipitation and heat-treated at 500 °C for 40 min and was characterized by powder X-ray diffraction (XRD). The sonocatalytic activities of ZnO/HA composite was carried out through the damage of bovine serum albumin (BSA) in aqueous solution. Furthermore, the effects of several factors on the damage of BSA molecules were evaluated by means of UV-vis and fluorescence spectra. Experimental results indicated that the damage degree of BSA aggravated with the increase of ultrasonic irradiation time, irradiation power and ZnO/HA addition amount, but weakened with the increase of solution acidity and ionic strength. In addition, the damage site to BSA was also studied by synchronous fluorescence technology and the damage site was mainly at tryptophan (Trp) residue. This paper provides a valuable reference for driving sonocatalytic method to treat tumor in clinic application.

  19. Osseointegration of loaded dental implant with KrF laser hydroxylapatite films on Ti6Al4V alloy by minipigs

    Science.gov (United States)

    Dostalova, Tatjana; Himmlova, Lucia; Jelinek, Miroslav; Grivas, Christos

    2001-04-01

    This study was performed with the objective of evaluating osseointegration of titanium alloy Ti6Al4V dental implants coated with hydroxylapatite (HA) deposited by a KrF laser. For this a KrF excimer laser and stainless-steel deposition chamber were used. The thickness of the HA films was approximately 1 micrometers . IN this investigation experimental animals minipigs were used; the implants were placed vertically into the lower jaw. After 14 weeks of unloaded osseointegration, metal-ceramic crowns were inserted and, at the same time, fluorescent solution was injected into the experimental animals. Six months after insertion of crowns the animals were sacrificed. The vertical position of the implants was checked by a radiograph. Microscopic sections were cut and ground, and the sections were examined under polarized and fluorescent light using a microscope with a charge coupled device camera. The six month long osseointegration in the lower jaw has confirmed the presence of newly formed bone around all the implants. In the experimental group, which had a laser-deposited coating, the layer of fibrous connective tissue was seen only randomly. In the control group (titanium implant without a cover) the fibrous connective tissue between the implant and the newly formed bone was observed more frequently, but this difference was not significant.

  20. Primary cell culture and morphological characterization of canine dermal papilla cells and dermal fibroblasts.

    Science.gov (United States)

    Bratka-Robia, Christine B; Mitteregger, Gerda; Aichinger, Amanda; Egerbacher, Monika; Helmreich, Magdalena; Bamberg, Elmar

    2002-02-01

    Skin biopsies were taken from female dogs, the primary hair follicles isolated and the dermal papilla dissected. After incubation in supplemented Amniomax complete C100 medium in 24-well culture plates, the dermal papilla cells (DPC) grew to confluence within 3 weeks. Thereafter, they were subcultivated every 7 days. Dermal fibroblast (DFB) cultures were established by explant culture of interfollicular dermis in serum-free medium, where they reached confluence in 10 days. They were subcultivated every 5 days. For immunohistochemistry, cells were grown on cover slips for 24 h, fixed and stained with antibodies against collagen IV and laminin. DPC showed an aggregative growth pattern and formation of pseudopapillae. Intensive staining for collagen IV and laminin could be observed until the sixth passage. DFB grew as branching, parallel lines and showed only weak staining for collagen IV and laminin.

  1. Toxicity of middle distillates from dermal exposure.

    Science.gov (United States)

    Koschier, F J

    1999-02-01

    This report focuses on recent studies that investigated the effects of kerosine dermal exposure on neurotoxicity and reproductive/developmental toxicity. Background toxicity information will also be reviewed for kerosine range mid distillates. The kerosine range mid distillates have a carbon range of C9-C16 and have a boiling range of 302-554 degrees F (150-290 degrees C). This category includes kerosine, aviation fuels (e.g., Jet A, JP-5 and JP-8), no. 1 fuel oil and diesel fuel oil. In general, the kerosine range mid distillates demonstrate relatively low acute toxicity by any route of exposure. High inhalation exposures can induce central nervous system depression characterized by ataxia, hypoactivity and prostration. Kerosines are known to cause skin irritation and inflammation under conditions of acute and repeated exposure in animals and humans, but are only slightly irritating to the eye and are not skin sensitizers. In addition, the absorption of kerosine range mid distillates through the skin has been demonstrated to be fairly rapid, but limited to approximately 10-15% of the applied dose after 24 hours. The kerosine range mid distillates are generally inactive in genetic toxicity tests although positive studies have been reported. Positive results, while at times equivocal, have been reported for straight run kerosine and jet fuel A in the mouse lymphoma assay with metabolic activation, and hydrodesulfurized kerosine (mouse) and jet fuel A (rat) in the bone marrow cytogenetic assay. Effects on the nervous and reproductive systems have been reported in humans and experimental animals under conditions where inhalation and dermal exposure to specific kerosine type fuels are sometimes difficult to separate. Recent laboratory studies have addressed this point and examined the effects of dermal exposure. In these studies, rats were exposed to hydrodesulfurized kerosine by skin application to determine the potential of dermal contact to cause reproductive

  2. Advanced Laser Techniques for Filler-Induced Complications

    DEFF Research Database (Denmark)

    Cassuto, D.; Marangoni, O.; Santis, G. De

    2009-01-01

    discomfort and pain. RESULTS All 20 patients experienced reduction or complete resolution, the latter increasing with repeated treatments. CONCLUSION Laser-assisted treatment offers a successful solution for patients who have been suffering from disfiguring nodules from injected fillersFoften for many years......BACKGROUND The increasing use of injectable fillers has been increasing the occurrence of disfiguring anaerobic infection or granulomas. This study presents two types of laser-assisted evacuation of filler material and inflammatory and necrotic tissue that were used to treat disfiguring facial...... nodules after different types of gel fillers. MATERIALS AND METHODS Infectious lesions after hydrogels were drained using a lithium triborate laser at 532 nm, with subsequent removal of infected gel and pus (laser assisted evacuation). Granuloma after gels containing microparticles were treated using...

  3. (Methacrylic Acid-Co-Divinylbenzene) Resin as Filler- Binder for ...

    African Journals Online (AJOL)

    Faculty of Pharmacy, Silpakorn University, Nakhon Pathom 73000, Thailand. Abstract ... Methods: Powder properties of PMD and MCC were characterized. Tablets ... with the widely used filler-binder, ... Gravimetric swelling was determined by.

  4. Analysis of filler particle levels and sizes in dental alginates

    Directory of Open Access Journals (Sweden)

    Hugo Lemes Carlo

    2010-06-01

    Full Text Available The aim of this study was to determine the inorganic filler fractions and sizes of commercially alginates. The inorganic particles volumetric fractions of five alginates - Jeltrate(J, Jeltrate Plus(JP, Jeltrate Chromatic Ortho(JC, Hydrogum(H and Ezact Krom(E were accessed by weighing a previously determined mass of each material in water before and after burning samples at 450 °C for 3 hours. Unsettled materials were soaked in acetone and chloroform and sputter-coated with gold for SEM evaluation of fillers' morphology and size. The results for the volumetric inorganic particle content were (%: J - 48.33, JP - 48.33, JC - 33.79, H - 37.55 and E - 40.55. The fillers presented a circular appearance with helical form and various perforations. Hydrogum fillers looked like cylindrical, perforated sticks. The mean values for fillers size were (μm: J - 12.91, JP - 13.67, JC - 13.44, E - 14.59 and H - 9 (diameter, 8.81 (length. The results of this study revealed differences in filler characteristics that could lead to different results when testing mechanical properties.

  5. Dermal exposure to monoterpenes during wood work.

    Science.gov (United States)

    Eriksson, Kare; Wiklund, Leif

    2004-06-01

    The dermal exposure to the suspected allergenic monoterpenes [small alpha]-pinene, [small beta]-pinene and [capital Delta](3)-carene was assessed with a patch sampling technique. The patch used was made of activated charcoal sandwiched between two layers of cotton cloth. Patches were fastened at 12 different spots on a sampling overall and at the front of a cap to estimate the potential exposure of the body. Fastening two patches on a cotton glove, one patch representing the dorsal side and one patch representing the palm of the hand respectively, assessed the exposure on the hands. Sampling was carried out during collecting of pine and spruce boards in sawmills and during sawing of pine wood pieces in joinery shops respectively. The potential dermal exposure of the total body was 29.0-1 890 mg h(-1) with a geometric mean (GM) of 238 mg h(-1) during sawing. During collecting the GM was estimated to 100 mg h(-1) with a range of 12.2-959 mg h(-1). The hands had a mean exposure of 9.24 mg h(-1) during sawing and 3.25 mg h(-1) during collecting respectively. The good correlation between the mass of contamination on the individual body parts and the potential body exposure indicates that sampling can be performed on one body part to give a good estimation of the potential body exposure. Monoterpenes were detected at patches fastened underneath the protective clothing indicating a contamination of the skin of the worker. The patch used may overestimate the dermal exposure.

  6. Evaluation of lymphangiogenesis in acellular dermal matrix

    Directory of Open Access Journals (Sweden)

    Mario Cherubino

    2014-01-01

    Full Text Available Introduction: Much attention has been directed towards understanding the phenomena of angiogenesis and lymphangiogenesis in wound healing. Thanks to the manifold dermal substitute available nowadays, wound treatment has improved greatly. Many studies have been published about angiogenesis and cell invasion in INTEGRA® . On the other hand, the development of the lymphatic network in acellular dermal matrix (ADM is a more obscure matter. In this article, we aim to characterize the different phases of host cell invasion in ADM. Special attention was given to lymphangiogenic aspects. Materials and Methods: Among 57 rats selected to analyse the role of ADM in lymphangiogenesis, we created four groups. We performed an excision procedure on both thighs of these rats: On the left one we did not perform any action except repairing the borders of the wound; while on the right one we used INTEGRA® implant. The excision biopsy was performed at four different times: First group after 7 days, second after 14 days, third after 21 days and fourth after 28 days. For our microscopic evaluation, we used the classical staining technique of haematoxylin and eosin and a semi-quantitative method in order to evaluate cellularity counts. To assess angiogenesis and lymphangiogenesis development we employed PROX-1 Ab and CD31/PECAM for immunohistochemical analysis. Results: We found remarkable wound contraction in defects that healed by secondary intention while minor wound contraction was observed in defects treated with ADM. At day 7, optical microscopy revealed a more plentiful cellularity in the granulation tissue compared with the dermal regeneration matrix. The immunohistochemical process highlighted vascular and lymphatic cells in both groups. After 14 days a high grade of fibrosis was noticeable in the non-treated group. At day 21, both lymphatic and vascular endothelial cells were better developed in the group with a dermal matrix application. At day 28

  7. Use of Porcine Acellular Dermal Matrix as a Dermal Substitute in Rats

    Science.gov (United States)

    Srivastava, Anil; DeSagun, Evangeline Z.; Jennings, Lawrence J.; Sethi, Stephen; Phuangsab, Anan; Hanumadass, Marella; Reyes, Hernan M.; Walter, Robert J.

    2001-01-01

    Objective To examine porcine acellular dermal matrix (ADM) as a xenogenic dermal substitute in a rat model. Summary Background Data Acellular dermal matrix has been used in the treatment of full-thickness skin injuries as an allogenic dermal substitute providing a stable wound base in human and animal studies. Methods Xenogenic and allogenic ADMs were produced by treating porcine or rat skin with Dispase and Triton X-100. Full-thickness skin defects (225 mm2) were created on the dorsum of rats (n = 29), porcine or rat ADMs were implanted in them, and these were overlain with ultrathin split-thickness skin grafts (STSGs). In two adjacent wounds, 0.005- or 0.017-inch-thick autografts were implanted. In other experiments, the antimicrobial agent used during ADM processing (azide or a mixture of antibiotics) and the orientation of the implanted ADM (papillary or reticular side of ADM facing the STSG) were studied. Grafts were evaluated grossly and histologically for 30 days after surgery. Results Significant wound contraction was seen at 14, 20, and 30 days after surgery in wounds receiving xenogenic ADM, allogenic ADM, and thin STSGs. Contraction of wounds containing xenogenic ADM was significantly greater than that of wounds containing allogenic ADM at 30 days after surgery. Graft take was poor in wounds containing xenogenic ADM and moderately good in those containing allogenic ADM. Wound healing was not significantly affected by the antimicrobial agent used during ADM preparation or by the ADM orientation. Conclusion Dispase–Triton-treated allogenic ADM was useful as a dermal substitute in full-thickness skin defects, but healing with xenogenic ADM was poor. PMID:11224629

  8. Comparison of long-term voice outcomes after vocal fold augmentation using autologous fat injection by direct microlaryngoscopy versus office-based calcium hydroxylapatite injection.

    Science.gov (United States)

    Zeleník, Karol; Walderová, Radana; Kučová, Hana; Jančatová, Debora; Komínek, Pavel

    2017-08-01

    The objective is to compare the long-term voice outcomes of vocal fold augmentation (VFA) using autologous fat injection via direct microlaryngoscopy versus office-based calcium hydroxylapatite (CaHA) injection. Patients with glottal insufficiency and a gap no greater than 3 mm caused by unilateral vocal fold paralysis or vocal fold atrophy were prospectively recruited to the study from September 2012 to September 2015. From September 2012 to May 2014, VFA was only performed using autologous fat via direct microlaryngoscopy under general anesthesia (N = 14). From May 2014 to September 2015, VFA was performed as an office-based procedure using a transoral approach to inject CaHA (N = 17). Videolaryngostroboscopic evaluation, subjective satisfaction with voice, voice handicap index (VHI), and maximal phonation time (MPT) were analyzed pre-injection and 12 months after VFA. A total of 31 patients were analyzed. One year after VFA, 67.8% of the patients were satisfied with their voice, with no significant difference between groups (P = 0.247). The mean improvement in VHI in the autologous fat group was 31.6 ± 16.82 versus 35 ± 27.24 in the CaHA group (P = 0.664). MPT improvement was also similar in the two groups: 5.5 ± 2.52 for the autologous fat group versus 6.0 ± 3.98 for the CaHA group (P = 0.823). Both autologous fat injection via direct microlaryngoscopy and office-based CaHA injection have good long-term results. There were no differences in the treatment results of the two procedures 1 year after injection.

  9. Dermal pharmacokinetics of microemulsion formulations determined by in vivo microdialysis

    DEFF Research Database (Denmark)

    Kreilgaard, Mads

    2001-01-01

    To investigate the potential of improving dermal drug delivery of hydrophilic and lipophilic substances by formulation in microemulsion vehicles and to establish a reliable pharmacokinetic model to analyze cutaneous microdialysis data.......To investigate the potential of improving dermal drug delivery of hydrophilic and lipophilic substances by formulation in microemulsion vehicles and to establish a reliable pharmacokinetic model to analyze cutaneous microdialysis data....

  10. Task-based dermal exposure models for regulatory risk assessment.

    Science.gov (United States)

    Warren, Nicholas D; Marquart, Hans; Christopher, Yvette; Laitinen, Juha; VAN Hemmen, Joop J

    2006-07-01

    The regulatory risk assessment of chemicals requires the estimation of occupational dermal exposure. Until recently, the models used were either based on limited data or were specific to a particular class of chemical or application. The EU project RISKOFDERM has gathered a considerable number of new measurements of dermal exposure together with detailed contextual information. This article describes the development of a set of generic task-based models capable of predicting potential dermal exposure to both solids and liquids in a wide range of situations. To facilitate modelling of the wide variety of dermal exposure situations six separate models were made for groupings of exposure scenarios called Dermal Exposure Operation units (DEO units). These task-based groupings cluster exposure scenarios with regard to the expected routes of dermal exposure and the expected influence of exposure determinants. Within these groupings linear mixed effect models were used to estimate the influence of various exposure determinants and to estimate components of variance. The models predict median potential dermal exposure rates for the hands and the rest of the body from the values of relevant exposure determinants. These rates are expressed as mg or microl product per minute. Using these median potential dermal exposure rates and an accompanying geometric standard deviation allows a range of exposure percentiles to be calculated.

  11. DREAM: a method for semi-quantitative dermal exposure assessment

    NARCIS (Netherlands)

    Wendel de Joode, B. van; Brouwer, D.H.; Kromhout, H.; Hemmen, J.J. van

    2003-01-01

    This paper describes a new method (DREAM) for structured, semi-quantitative dermal exposure assessment for chemical or biological agents that can be used in occupational hygiene or epidemiology. It is anticipated that DREAM could serve as an initial assessment of dermal exposure, amongst others,

  12. Mesenchymal stem cells induce dermal fibroblast responses to injury

    International Nuclear Information System (INIS)

    Smith, Andria N.; Willis, Elise; Chan, Vincent T.; Muffley, Lara A.; Isik, F. Frank; Gibran, Nicole S.; Hocking, Anne M.

    2010-01-01

    Although bone marrow-derived mesenchymal stem cells have been shown to promote repair when applied to cutaneous wounds, the mechanism for this response remains to be determined. The aim of this study was to determine the effects of paracrine signaling from mesenchymal stem cells on dermal fibroblast responses to injury including proliferation, migration and expression of genes important in wound repair. Dermal fibroblasts were co-cultured with bone marrow-derived mesenchymal stem cells grown in inserts, which allowed for paracrine interactions without direct cell contact. In this co-culture model, bone marrow-derived mesenchymal stem cells regulate dermal fibroblast proliferation, migration and gene expression. When co-cultured with mesenchymal stem cells, dermal fibroblasts show increased proliferation and accelerated migration in a scratch assay. A chemotaxis assay also demonstrated that dermal fibroblasts migrate towards bone marrow-derived mesenchymal stem cells. A PCR array was used to analyze the effect of mesenchymal stem cells on dermal fibroblast gene expression. In response to mesenchymal stem cells, dermal fibroblasts up-regulate integrin alpha 7 expression and down-regulate expression of ICAM1, VCAM1 and MMP11. These observations suggest that mesenchymal stem cells may provide an important early signal for dermal fibroblast responses to cutaneous injury.

  13. Post Kala-azar Dermal Leishmaniasis (PKDL) In vivo veritas

    Indian Academy of Sciences (India)

    Immunology LAB-1

    2016-08-26

    Aug 26, 2016 ... 50. 100. 150. 200. 250. 300. 0. 200. 400. 600. 800. 1000. 1200. 1400. 1600 ... Rapid diagnostic tests exist (PKDL?) • Effective ... ld (C t). No: of parasites/ 200 µl of blood. Post Kala Azar Dermal Leishmaniasis (PKDL); dermal ...

  14. Hyaluronic acid filler injections for tear-trough deformity: injection technique and high-frequency ultrasound follow-up evaluation.

    Science.gov (United States)

    De Pasquale, Antonino; Russa, Giuseppina; Pulvirenti, Manuela; Di Rosa, Luigi

    2013-06-01

    This study aimed to describe the technique used by the authors in treating tear-trough deformity and to illustrate the effectiveness of high-frequency diagnostic ultrasound in the assessment of dermal filler longevity. In this consecutive interventional nonrandomized case series, 22 patients (18 women and 4 men) were evaluated. They ranged in age from 29 to 65 years (mean, 46.59 years ± 10.0 years). The patients were given multiple hyaluronic acid injections in the tear-trough area between 2009 and 2011. The injected areas then were evaluated with sonographic scans during the follow-up period. All the patients were examined preoperatively, 7 days after injection, then after 1, 6, and 12 months, and finally once a year. Pre- and postoperative photographs using standard positioning and lighting were taken as well as high-frequency ultrasound scans using a 15-MHz scanner with an axial resolution of 15 mm. The injection technique consisted of three to five injections perpendicular to the skin. These were administered just under the orbital rim, creating three column-shaped hyaluronic acid deposits deep in the orbicularis oculi muscle, from 0.2 mm to 0.5 mm below the orbital rim. Approximately 0.1 ml-0.3 ml was injected at a time. This technique creates a deep scaffolding that can fill the orbital hollow. The amount of filler used in each area ranged from 0.1 ml to 0.3 ml (mean, 0.267 ml ± 0.128 ml), whereas the mean filler quantity in each eyelid was 0.45 ml ± 0.14 ml. During the follow-up visit 1 week after the treatment, 21 patients (90 %) required a second series of injections either in the exact same areas or right next to the injected area to obtain a smoother appearance of the skin surface. During the sonographer examination, it was always possible to identify and measure the filler at the site of the injection. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please

  15. Labia Majora Augmentation with Hyaluronic Acid Filler: Technique and Results.

    Science.gov (United States)

    Fasola, Elena; Gazzola, Riccardo

    2016-11-01

    External female genitalia lose elasticity and volume with age. In the literature several techniques address the redundancy of the labia minora, but only few reports describe the augmentation of labia majora with fat grafting. At present, no studies describe the augmentation of the labia majora with hyaluronic acid. This study aims to present our technique of infiltration of hyaluronic acid filler, analyzing effectiveness, patient satisfaction, and complications. We retrospectively analyzed 54 patients affected by hypotrophy of the labia majora; they were treated with hyaluronic acid filler between November 2010 and December 2014. The Global Aesthetic Improvement Scale (GAIS) filled out by the doctor and the patients was used to evaluate the results 12 months after the infiltration. Complications were recorded. A total of 31 patients affected by mild to moderate labia majora hypotrophy were treated with 19 mg/mL HA filler; 23 patients affected by severe labia majora hypotrophy were treated with 21 mg/mL HA filler. Among the first group of patients, one underwent a second infiltration 6 months later with 19 mg/mL HA filler (maximum 1 mL). A significant improvement (P labia majora is able to provide a significant rejuvenation with a simple outpatient procedure. We achieved significant improvements with one infiltration in all cases. The treatment is repeatable, has virtually no complications and it is reversible. 4 Therapeutic. © 2016 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  16. An investigation of tendon sheathing filler migration into concrete

    International Nuclear Information System (INIS)

    Naus, D.J.; Oland, C.B.

    1998-03-01

    During some of the inspections at nuclear power plants with prestressed concrete containments, it was observed that the containments has experienced leakage of the tendon sheathing filler (i.e., streaks). The objective of this activity was to provide an indication of the extent of tendon sheathing filler leakage into the concrete and its affects on concrete properties. Literature was reviewed and concrete core samples were obtained from the Trojan Nuclear Plant and tested. The literature primarily addressed effects of crude or lubricating oils that are known to cause concrete damage. However, these materials have significantly different characteristics relative to the materials used as tendon sheathing fillers. Examination and testing of the concrete cores indicated that the appearance of tendon sheathing filler on the concrete surface was due to leakage from the conduits and its subsequent migration through cracks that were present. Migration of the tendon sheathing filler was confined to the cracks and there was no perceptible movement into the concrete. Results of compressive strength testing indicated that the concrete quality was consistent in the containment and that the strength had increased over 40% in 25.4 years relative to the average compressive strength at 28-days age

  17. Influence of reactive fillers on concrete corrosion resistance

    Science.gov (United States)

    Rakhimbayev, Sh M.; Tolypina, N. M.; Khakhaleva, E. N.

    2018-03-01

    Contact surfaces represent the weakest link in a conglomerate structure of materials. They ensure the diffusion of aggressive agents inside the material. To reduce the conductivity of contact surfaces it is advisable to use reactive fillers, which interact with cement matrix via certain mechanisms, which in turn, reduces the permeability of the contact layer and fosters durability of products. The interaction of reactive fillers with calcium hydroxide of a concrete liquid phase in a contact area leads to the formation of hydrated calcium silicates of a tobermorite group. Such compounds, being settled in pores and capillaries of a product, colmatage and clog them to some extent thus leading to diffusion delay (inhibition) with regard to aggressive components of external media inside porous material, which in turn inhibits the corrosion rate. The authors studied and compared the corrosion of cement concrete with a standard filler (quartz sand) and a reactive filler (perlite and urtit). The experiments confirmed the positive influence of active fillers on concrete corrosion resistance.

  18. Solidification behavior of austenitic stainless steel filler metals

    International Nuclear Information System (INIS)

    David, S.A.; Goodwin, G.M.; Braski, D.N.

    1980-02-01

    Thermal analysis and interrupted solidification experiments on selected austenitic stainless steel filler metals provided an understanding of the solidification behavior of austenitic stainless steel welds. The sequences of phase separations found were for type 308 stainless steel filler metal, L + L + delta + L + delta + γ → γ + delta, and for type 310 stainless steel filler metal, L → L + γ → γ. In type 308 stainless steel filler metal, ferrite at room temperature was identified as either the untransformed primary delta-ferrite formed during the initial stages of solidification or the residual ferrite after Widmanstaetten austenite precipitation. Microprobe and scanning transmission electron microscope microanalyses revealed that solute extensively redistributes during the transformation of primary delta-ferrite to austenite, leading to enrichment and stabilization of ferrite by chromium. The type 310 stainless steel filler metal investigated solidifies by the primary crystallization of austenite, with the transformation going to completion at the solidus temperature. In our samples residual ferrite resulting from solute segregation was absent at the intercellular or interdendritic regions

  19. Soft tissue augmentation 2006: filler fantasy.

    Science.gov (United States)

    Klein, Arnold William

    2006-01-01

    As an increasing number of patients seek esthetic improvement through minimally invasive procedures, interest in soft tissue augmentation and filling agents is at an all-time high. One reason for this interest is the availability of botulinum toxin type A, which works superbly in the upper face. The rejuvenation of the upper face has created much interest in injectable filling agents and implant techniques that work equally well in the restoration of the lower face. One of the central tenets of soft tissue augmentation is the concept of the three-dimensional face. The youthful face has a soft, full appearance, as opposed to the flat, pulled, two-dimensional look often achieved by more traditional surgical approaches. Injectable filling agents can augment and even at times, replace pulling. Additionally, with the lip as the focal center of the lower face, subtle lip enhancement is here to stay, and is in fact, the number one indication for injectable fillers. Moreover, minimally invasive soft tissue augmentation offers cosmetic enhancement without the cost and recovery time associated with more invasive procedures. As more and more physicians take interest in minimally invasive surgery, courses in cosmetic surgery techniques are becoming increasingly popular at the medical meetings of many specialties. Today, physicians have a much larger armamentarium of techniques and materials with which to improve facial contours, ameliorate wrinkles, and provide esthetic rejuvenation to the face. For a substance or device to be amenable for soft tissue augmentation in the medical community, it must meet certain criteria. It must have both a high "use" potential, producing cosmetically pleasing results with a minimum undesirable reactions, and have a low abuse potential in that widespread or incorrect or indiscriminate use would not result in significant morbidity. It must be nonteratogenic, noncarcinogenic, and nonmigratory. In addition, the agent must provide predictable

  20. Carboxylated nitrile butadiene rubber/hybrid filler composites

    Directory of Open Access Journals (Sweden)

    Ahmad Mousa

    2012-08-01

    Full Text Available The surface properties of the OSW and NLS are measured with the dynamic contact-angle technique. The x-ray photoelectron spectroscopy (XPS of the OSW reveals that the OSW possesses various reactive functional groups namely hydroxyl groups (OH. Hybrid filler from NLS and OSW were incorporated into carboxylated nitrile rubber (XNBR to produce XNBR hybrid composites. The reaction of OH groups from the OSW with COOH of the XNBR is checked by attenuated total reflectance spectra (ATR-IR of the composites. The degree of curing ΔM (maximum torque-minimum torque as a function of hybrid filler as derived from moving die rheometer (MDR is reported. The stress-strain behavior of the hybrid composites as well as the dynamic mechanical thermal analysis (DMTA is studied. Bonding quality and dispersion of the hybrid filler with and in XNBR are examined using scanning-transmission electron microscopy (STEM in SEM.

  1. [Ideas about registration for sodium hyaluronate facial derma fillers].

    Science.gov (United States)

    Zhao, Peng; Shi, Xinli; Liu, Wenbo; Lu, Hong

    2012-09-01

    To review the registration and technical data for sodium hyaluronate facial derma fillers. Recent literature concerning registration for sodium hyaluronate facial derma fillers was reviewed and analyzed. The aspects on registration for sodium hyaluronate facial derma fillers include nominating the product, dividing registration unit, filling in a registration application form, preparing the technical data, developing the standard, and developing a registration specification. The main difficulty in registration is how to prepare the research data of that product, so the manufacturers need to enhance their basic research ability and work out a scientific technique routing which could ensure the safety and effectiveness of the product, also help to set up the supportive documents to medical device registration.

  2. Brazing of Cu with Pd-based metallic glass filler

    Energy Technology Data Exchange (ETDEWEB)

    Terajima, Takeshi [Joining and Welding Research Institute, Osaka University, 11-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan)], E-mail: terajima@jwri.osaka-u.ac.jp; Nakata, Kazuhiro [Joining and Welding Research Institute, Osaka University, 11-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Matsumoto, Yuji [Materials and Structures Laboratory, Tokyo Institute of Technology (Japan); Zhang, Wei; Kimura, Hisamichi; Inoue, Akihisa [Institute for Materials Research, Tohoku University (Japan)

    2008-02-25

    Metallic glass has several unique properties, including high mechanical strength, small solidification shrinkage, small elastic modulus and supercooling state, all of which are well suited as a residual stress buffer for metal and ceramic joining. In the present preliminary study, we demonstrated brazing of Cu rods with Pd{sub 40}Cu{sub 30}Ni{sub 10}P{sub 20} metallic glass filler. The brazing was carried out at 873 K for 1 min in a vacuum atmosphere (1 x 10{sup -3} Pa), and then the specimens were quenched at the rate of 30 K/s by blowing He. The metallic glass brazing of Cu using Pd{sub 40}Cu{sub 30}Ni{sub 10}P{sub 20} filler was successful, with the exception that several voids remained in the filler. According to micro-focused X-ray diffraction, no diffraction patterns were observed at both the center of the Pd{sub 40}Cu{sub 30}Ni{sub 10}P{sub 20} filler and the Cu/Pd{sub 40}Cu{sub 30}Ni{sub 10}P{sub 20} interface. The result showed that the Cu specimens were joined with Pd{sub 40}Cu{sub 30}Ni{sub 10}P{sub 20} filler in the glassy state. The tensile fracture strength of the brazed specimens ranged from 20 to 250 MPa. The crack extension from the voids in the Pd{sub 40}Cu{sub 30}Ni{sub 10}P{sub 20} filler may have caused the results to be uneven and very low compared to the strength of Pd-based bulk metallic glass.

  3. Lower Face: Clinical Anatomy and Regional Approaches with Injectable Fillers.

    Science.gov (United States)

    Braz, André; Humphrey, Shannon; Weinkle, Susan; Yee, G Jackie; Remington, B Kent; Lorenc, Z Paul; Yoelin, Steve; Waldorf, Heidi A; Azizzadeh, Babak; Butterwick, Kimberly J; de Maio, Mauricio; Sadick, Neil; Trevidic, Patrick; Criollo-Lamilla, Gisella; Garcia, Philippe

    2015-11-01

    The use of injectable fillers enables facial sculpting through treatment of volume depletion and modeling of facial contours. Injectable fillers are among the most frequently performed minimally invasive cosmetic procedures.However, treatment of the lower third of the face can be challenging and requires expertise in facial anatomy. In this article, the authors provide a comprehensive review of the anatomy of the lower third of the face, highlighting danger zones. In addition, the authors describe their preferred approach and detailed technique used in the treatment of each specific area, namely the jawline, prejowl sulcus, melomental folds, and lips.

  4. Effect of the filler on radiolysis of filled elastomers

    International Nuclear Information System (INIS)

    Komarov, S.A.; Erastov, A.Kh.; Kolesnikov, A.A.; Gostikina, A.V.; Mal'kov, A.M.; Korovkin, V.V.

    1987-01-01

    The effect of the type and concentration of filler (A-175 Aerosil, PM-75 technical carbon, BS-100 white black, kaolin, titanium oxide) on the radiation yield of elastomers of different chemical nature was studied. The extreme character of the dependence of the radiation yield of paramagnetic centers on the concentration of filler, common to the systems studied, was established; it was due to the features of the colloid chemical structure of the filled elastomers and particularly to processes of cross-linking of the filter

  5. Formulation of diclofenac for dermal delivery.

    Science.gov (United States)

    Goh, Choon Fu; Lane, Majella E

    2014-10-01

    Diclofenac (DF) was first synthesized in the 1960's and is currently available as ophthalmic, oral, parenteral, rectal and skin preparations. This review focuses on the administration of DF to the skin. As a member of the non-steroidal anti-inflammatory (NSAID) group of drugs the primary indications of DF are for the management of inflammation and pain but it is also used to treat actinic keratosis. The specific aims of this paper are to: (i) provide an overview of the pharmacokinetics and metabolism of DF following oral and topical administration; (ii) examine critically the various formulation approaches which have been investigated to enhance dermal delivery of DF; and (iii) identify new formulation strategies for enhanced DF skin penetration. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Dissolving Microneedle Patches for Dermal Vaccination.

    Science.gov (United States)

    Leone, M; Mönkäre, J; Bouwstra, J A; Kersten, G

    2017-11-01

    The dermal route is an attractive route for vaccine delivery due to the easy skin accessibility and a dense network of immune cells in the skin. The development of microneedles is crucial to take advantage of the skin immunization and simultaneously to overcome problems related to vaccination by conventional needles (e.g. pain, needle-stick injuries or needle re-use). This review focuses on dissolving microneedles that after penetration into the skin dissolve releasing the encapsulated antigen. The microneedle patch fabrication techniques and their challenges are discussed as well as the microneedle characterization methods and antigen stability aspects. The immunogenicity of antigens formulated in dissolving microneedles are addressed. Finally, the early clinical development is discussed.

  7. Effect of precipitated calcium carbonate--Cellulose nanofibrils composite filler on paper properties.

    Science.gov (United States)

    He, Ming; Cho, Byoung-Uk; Won, Jong Myoung

    2016-01-20

    A new concept of composite filler was developed by using cellulose nanofibrils (CNF), precipitated calcium carbonate (PCC) and cationic starch (C-starch). In this study, cellulose nanofibrils were utilized in two different ways: a PCC-CNF composite filler and a papermaking additive in sheet forming. The aim was to elucidate their effects on flocculation, filler retention and the strength and optical properties of handsheets. The highest filler retention was obtained by using the PCC-CNF composite filler in paper sheets. The paper filled with the composite fillers had much higher bursting and tensile strengths than conventional PCC loading. It was also found that the paper prepared with PCC-CNF composite fillers became denser with increasing the filler content of paper. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Glass transition temperature of polymer nano-composites with polymer and filler interactions

    Science.gov (United States)

    Hagita, Katsumi; Takano, Hiroshi; Doi, Masao; Morita, Hiroshi

    2012-02-01

    We systematically studied versatile coarse-grained model (bead spring model) to describe filled polymer nano-composites for coarse-grained (Kremer-Grest model) molecular dynamics simulations. This model consists of long polymers, crosslink, and fillers. We used the hollow structure as the filler to describe rigid spherical fillers with small computing costs. Our filler model consists of surface particles of icosahedra fullerene structure C320 and a repulsive force from the center of the filler is applied to the surface particles in order to make a sphere and rigid. The filler's diameter is 12 times of beads of the polymers. As the first test of our model, we study temperature dependence of volumes of periodic boundary conditions under constant pressures through NPT constant Andersen algorithm. It is found that Glass transition temperature (Tg) decrease with increasing filler's volume fraction for the case of repulsive interaction between polymer and fillers and Tg weakly increase for attractive interaction.

  9. The radiological features of Goltz syndrome: Focal dermal hypoplasia

    International Nuclear Information System (INIS)

    Boothyrod, A.E.; Hall, C.M.

    1988-01-01

    Two female infants with Goltz syndrome (focal dermal hypoplasia) were recently investigated for severe feeding problems and failure to thrive. Both demonstrated severe skeletal malformations and marked gastrooesophageal reflux with laxity of the hiatus. One child (case 1) exhibited nasal regurgitation during feeding. Interestingly, both children had undergone surgery; Case 1 or a right parasagittal abdominal hernia associated with focal dermal hypoplasia of the abdominal wall and Case 2 for an exomphalos also associated with dermal hypoplasia. This observation suggests more widespread mesodermal abnormality. (orig./GDG)

  10. Influencia de la adición del filler calizo sobre el fraguado del cemento

    Directory of Open Access Journals (Sweden)

    Menéndez, Ignacio

    1993-09-01

    Full Text Available The present paper deals about the infuence that addition of calcareous "filler" has on the set of portland cement which rates are from 0 up to 50% of filler.

    En el presente artículo se estudia la influencia que la adición de "filler" calizo ejerce sobre el fraguado del cemento portland, al que se le añaden porcentajes desde O al 50% en filler.

  11. Safety and persistence of non-animal stabilized hyaluronic acid fillers for nasolabial folds correction in 30 Indian patients

    Directory of Open Access Journals (Sweden)

    Shehnaz Z Arsiwala

    2010-01-01

    Full Text Available Background: Correction of nasolabial creases through minimally invasive procedures is increasingly being sought by patients. Injecting non-animal stabilized hyaluronic acid filler is a highly effective method to achieve an optimal and persistent cosmetic result. Aims: To evaluate the efficacy, persistence and safety of Restylane and Perlane (Q-Med, Sweden for correction of nasolabial folds in Indian patients. Materials and Methods: Thirty Indian patients with mild, moderate and severe nasolabial folds (based on Wrinkle Assessment Scale were recruited in the study after informed consent for correction of their folds with Restylane or Perlane or both. Injections were administered in a single sitting after global assessment of the patient′s face using Wrinkle assessment scale (WAS.Optimal filling was performed by using appropriate techniques and its safety and efficacy assessed independently by the investigator as well as by patients at immediately, 3, 6 and 9 months post-procedure. Any adverse reactions were noted. Results: Twenty two females and 8 males (age range 45-55 years, mean age 52 years were recruited in the study. An optimum cosmetic correction was obtained in all patients. The efficacy increased with time and was greatest at 3 months after the treatment. Grade 2 improvement was maintained at 9 months in mild and moderate folds, and grade 3 improvement for severe folds. Minor post injection side effects like erythema at puncture site, needle marks and bruising were seen. Conclusion: Restylane and Perlane are safe and effective dermal fillers for correction of nasolabial creases and offer immediate effect.

  12. Effect of waste rubber powder as filler for plywood application

    Directory of Open Access Journals (Sweden)

    Ong Huei Ruey

    2015-03-01

    Full Text Available The study investigated the suitability of waste rubber powder (WRP use as filler in adhesive formulation for plywood application. Melamine Urea Formaldehyde (MUF was employed as resin for formulating the wood adhesive. To improve chemical properties and bonding quality of adhesive, WRP was treated by different chemicals like 20% nitric acid, 30% hydrogen peroxide and acetone solution. The treated WRP were analysed by XRD and it showed that inorganic compounds were removed and carbon was remained as major component under the treatment of 20% HNO3. The treatment improved the mechanical properties like shear strength and formaldehyde emission of plywood (high shear strength and low formaldehyde emission. The physico-chemical interaction between the wood, resin and filler was investigated using fourier transform infrared spectroscopic (FTIR technique and the interactions among N-H of MUF and C=O of wood and WRP were identified. The morphology of wood-adhesive interface was studied by field emission scanning electron microscope (FESEM and light microscope (LM. It showed that the penetration of adhesives and fillers through the wood pores was responsible for mechanical interlocking. Therefore, chemically treated WRP proved its potential use as filler in MUF based adhesive for making plywood.

  13. Hydrogels from radiation crosslinked blends of hydrophilic polymers and fillers

    International Nuclear Information System (INIS)

    Yen, S.N.; Osterholtz, F.D.

    1975-01-01

    Particulate, free-flowing, insoluble swellable polymers are provided which are comprised of a mixture of an insoluble, swellable hydrogel and inert filler. The mixtures are free-flowing powders or granules which can absorb many times their weight of water and hence are useful as a soil amendment

  14. Automatic reel controls filler wire in welding machines

    Science.gov (United States)

    Millett, A. V.

    1966-01-01

    Automatic reel on automatic welding equipment takes up slack in the reel-fed filler wire when welding operation is terminated. The reel maintains constant, adjustable tension on the wire during the welding operation and rewinds the wire from the wire feed unit when the welding is completed.

  15. 14 CFR 23.973 - Fuel tank filler connection.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel tank filler connection. 23.973 Section 23.973 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23...

  16. Fibrous Fillers to Manufacture Ultra High Ash/Performance Paper

    Energy Technology Data Exchange (ETDEWEB)

    Dr. VIjay K. Mathur

    2009-04-30

    The paper industry is one of the largest users of energy and emitters of CO2 in the US manufacturing industry. In addition to that, it is facing tremendous financial pressure due to lower cost imports. The fine paper industry has shrunk from 15 million tons per year production to 10 million tons per year in the last 5 years. This has resulted in mill closures and job loses. The AF&PA and the DOE formed a program called Agenda 2020 to help in funding to develop breakthrough technologies to provide help in meeting these challenges. The objectives of this project were to optimize and scale-up Fibrous Fillers technology, ready for commercial deployment and to develop ultra high ash/high performance paper using Fibrous Fillers. The goal was to reduce energy consumption, carbon footprint, and cost of manufacturing paper and related industries. GRI International (GRI) has been able to demonstrate the techno - economic feasibility and economic advantages of using its various products in both handsheets as well as in commercial paper mills. GRI has also been able to develop sophisticated models that demonstrate the effect of combinations of GRI's fillers at multiple filler levels. GRI has also been able to develop, optimize, and successfully scale-up new products for use in commercial paper mills.

  17. Influence of fillers on the alkali activated chamotte

    Science.gov (United States)

    Dembovska, L.; Bumanis, G.; Vitola, L.; Bajare, D.

    2017-10-01

    Alkali-activated materials (AAM) exhibit remarkable high-temperature resistance which makes them perspective materials for high-temperature applications, for instance as fire protecting and insulating materials in industrial furnaces. Series of experiments were carried out to develop optimum mix proportions of AAM based on chamotte with quartz sand (Q), olivine sand (OL) and firebrick sawing residues (K26) as fillers. Aluminium scrap recycling waste was considered as a pore forming agent and 6M NaOH alkali activation solution has been used. Lightweight porous AAM have been obtained with density in range from 600 to 880 kg/m3 and compressive strength from 0.8 to 2.7 MPa. The XRD and high temperature optical microscopy was used to characterize the performance of AAM. The mechanical, physical and structural properties of the AAM were determined after the exposure to elevated temperatures at 800 and 1000°C. The results indicate that most promising results for AAM were with K26 filler where strength increase was observed while Q and OL filler reduced mechanical properties due to structure deterioration caused by expansive nature of selected filler.

  18. Bacterial biofilm formation and treatment in soft tissue fillers

    DEFF Research Database (Denmark)

    Alhede, Morten; Er, Ozge; Eickhardt, Steffen

    2014-01-01

    that once the bacteria had settled (into biofilms) within the gels, even succesive treatments with high concentrations of relevant antibiotics were not effective. Our data substantiate bacteria as a cause of adverse reactions reported when using tissue fillers, and the sustainability of these infections...

  19. Hybrid filler composition optimization for tensile strength of jute fibre

    Indian Academy of Sciences (India)

    https://www.ias.ac.in/article/fulltext/boms/039/05/1223-1231 ... The developed composite consists of natural jute fibre as reinforcement and unsaturated ... The effect of weight content of bagasse fibre, carbon black and calcium carbonate ... of pultruded jute fibre polymer composite at the optimum composition of hybrid filler.

  20. New Manufacturing Method for Paper Filler and Fiber Material

    Energy Technology Data Exchange (ETDEWEB)

    Doelle, Klaus [SUNY College of Environmental Science and Forestry

    2013-08-25

    The use of fillers in printing and writing papers has become a prerequisite for competing in a global market to reduce the cost of materials. Use of calcium carbonates (ranging from 18% to 30%) as filler is a common practice in the paper industry but the choices of fillers for each type of papers vary widely according to its use. The market for uncoated digital printing paper is one that continues to introduce exciting growth projections. and it is important to understand the effect that new manufacturing methods of calcium carbonates have on the energy efficiency and paper production. Research conducted under this award showed that the new fiber filler composite material has the potential to increase the paper filler content by up to 5% without losing mechanical properties. Benefits of the technology can be summarized as follows for a 1% filler increase per metric ton of paper produced: (i) production cost savings over $12, (ii) Energy savings of 100,900 btu, (iii) CO{sub 2} emission savings of 33 lbs, and additional savings for wood preparation, pulping, recovery of 203593 btu with a 46lbs of CO{sub 2} emission savings per 1% filler increase. In addition the technology has the potential to save: (i) additional $3 per ton of bleached pulp produced, (ii) bleaching energy savings of 170,000 btu, (iii) bleaching CO{sub 2} emission savings of 39 lbs, and (iv) additional savings for replacing conventional bleaching chemicals with a sustainable bleaching chemical is estimated to be 900,000 btu with a 205 lbs of CO{sub 2} emission savings per ton of bleached pulp produced. All the above translates to a estimated annual savings for a 12% filler increase of 296 trillion buts or 51 million barrel of oil equivalent (BOE) or 13.7% of the industries energy demand. This can lead to a increase of renewable energy usage from 56% to close to 70% for the industry sector. CO{sub 2} emission of the industry at a 12% filler increase could be lowered by over 39 million tons annually

  1. Mechanical properties of HDPE/UHMWPE blends: effect of filler loading and filler treatment.

    Science.gov (United States)

    Lai, K L K; Roziyanna, A; Ogunniyi, D S; Zainal, Arifin M I; Azlan, Ariffin A

    2004-05-01

    Various blend ratios of high-density polyethylene (HDPE) and ultra high molecular weight polyethylene (UHMWPE) were prepared with the objective of determining their suitability as biomaterials. In the unfilled state, a blend of 50/50 (HDPE/UHMWPE) ratio by weight was found to yield optimum properties in terms of processability and mechanical properties. Hydroxyapatite (HA) was compounded with the optimum blend ratio. The effects of HA loading, varied from 0 to 50wt% for both filled and unfilled blends were tested for mechanical properties. It was found that the inclusion of HA in the blend led to a remarkable improvement of mechanical properties compared to the unfilled blend. In order to improve the bonding between the polymer blend and the filler, the HA used was chemically treated with a coupling agent known as 3-(trimethoxysiyl) propyl methacrylate and the treated HA was mixed into the blend. The effect of mixing the blend with silane-treated HA also led to an overall improvement of mechanical properties.

  2. Biocompatibility and tissue regenerating capacity of crosslinked dermal sheep collagen

    NARCIS (Netherlands)

    van Wachem, P.B.; van Luyn, M.J.A.; Olde Damink, L.H.H.; Olde damink, L.H.H.; Dijkstra, Pieter J.; Feijen, Jan; Nieuwenhuis, P.

    1994-01-01

    The biocompatibility and tissue regenerating capacity of four crosslinked dermal sheep collagens (DSC) was studied. In vitro, the four DSC versions were found to be noncytotoxic or very low in cytoxicity. After subcutaneous implantation in rats, hexamethylenediisocyanatecrcrosslinked DSC (HDSC)

  3. Pigmentation and dermal conservative effects of the astonishing ...

    African Journals Online (AJOL)

    Background: The preference for a fairer skin-tone has become a common trend ... to evaluate the potent dermal protective effect of the two seaweeds Sargassum ... Extracts with potent melanocytotoxicity were formulated into cosmetic cream ...

  4. Management of acute complex traumatic wound with a dermal ...

    African Journals Online (AJOL)

    Background: Acute complex traumatic wounds of the lower limbs are usually ... The recovery is lengthy, and the outcome dependent on the initial injury, the surgical ... of fracture and use of a dermal regeneration template over the fracture site, ...

  5. Brain abscess as a manifestation of spinal dermal sinus

    Directory of Open Access Journals (Sweden)

    Parisa Emami-Naeini

    2008-09-01

    Full Text Available Parisa Emami-Naeini, Ali Mahdavi, Hamed Ahmadi, Nima Baradaran, Farideh NejatDepartment of Neurosurgery, Children’s Hospital Medical Center, Medical Sciences/University of Tehran, Tehran, IranAbstract: Dermal sinuses have been associated with a wide spectrum of clinical manifestations ranging from asymptomatic to drainage of purulent material from the sinus tract, inclusion tumors, meningitis, and spinal abscess. To date, there has been no documented report of brain abscess as a complication of spinal dermal sinus. Here, we report an 8-month-old girl who was presented initially with a brain abscess at early infancy but lumbar dermal sinus and associated spinal abscess were discovered afterwards. The probable mechanisms of this rare association have been discussed.Keywords: brain abscess, spinal dermal sinus, spinal abscess

  6. Dermal Sensitization Potential of Triethyleneglycol Dinitrate (TEGDN) in Guinea Pigs

    Science.gov (United States)

    1989-01-01

    mutagenicity assay, acute oral toxicity tests in rats and mice, acute dermal toxicity in rabbits, dermal and ocular irritation studies in rabbits, and...conditions: 85E0102 had diffuse tracheitis, mild endocarditis , mild hepatitis, and diffuse pigment granules in the small intestine; 85E0103 had mild...severe ulceration progressing to necrosis. Sensitization is manifested as indirect inflammation mediated by components of the immune system in

  7. Proof-of-Principle Dermal Decontamination Experiments: Swine Skin

    Science.gov (United States)

    2007-04-01

    cycles and the measurements taken after each cycle were recorded. All water rinses were performed using tap water and applied using a gentle stream...uniform and highly reproducible. EpiDermFT ( EFT ) consists of organized basal, spinous, granular, and cornified epidermal layers analogous to those found...in vivo. The dermal compartment is composed of a collagen matrix containing viable normal human dermal fibroblasts (NHDF). EFT is mitotically and

  8. Comparison of TT-F-1098 Solvent-Thinned Block Fillers with Water-Thinnable Block Fillers.

    Science.gov (United States)

    1985-03-01

    saved money , because the latex is less roller were visible. The appearance of the surface expensive than the epoxy it replaced. In both cases...a previous coating. A kit manu- The appearance of all the fillers was satisfactory. factured b, Paul N. Gardner Company, Inc., Lauder - Voids were

  9. Effects of fillers on the properties of liquid silicone rubbers (LSRs)

    DEFF Research Database (Denmark)

    Yu, Liyun; Vudayagiri, Sindhu; Zakaria, Shamsul Bin

    these additives, the use of multiple titanium dioxides as filler potentially suits to special applications. In the present study, a series of TiO2 fillers were blended into LSRs, such as hydrophilic/ hydrophobic, micro/ nano scale, anatase/ rutile crystal, sphere/ core-shell structure. The results indicate...... of inorganic fillers. The property improvement of the filled LSRs depends on filler concentration, filler morphology, such as particle size and structure, the degree of dispersion and orientation in the matrix, and also the degree of adhesion with the polymer chains, as well as the properties of the inorganic...

  10. Hardness of model dental composites - the effect of filler volume fraction and silanation.

    Science.gov (United States)

    McCabe, J F; Wassell, R W

    1999-05-01

    The relationship between structure and mechanical properties for dental composites has often proved difficult to determine due to the use of commercially available materials having a number of differences in composition i.e. different type of resin, different type of filler, etc. This makes a scientific study of any one variable such as filler content difficult if not impossible. In the current study it was the aim to test the hypothesis that hardness measurements of dental composites could be used to monitor the status of the resin-filler interface and to determine the efficacy of any particle silanation process. Ten model composites formulated from a single batch of resin and containing a common type of glass filler were formulated to contain varying amounts of filler. Some materials contained silanated filler, others contained unsilanated filler. Specimens were prepared and stored in water and hardness (Vickers') was determined at 24 h using loads of 50, 100, 200 and 300 g. Composites containing silanated fillers were significantly harder than materials containing unsilanated fillers. For unsilanated products hardness was independent of applied load and in this respect they behaved like homogeneous materials. For composites containing silanated fillers there was a marked increase in measured hardness as applied load was increased. This suggests that the hardness-load profile could be used to monitor the status of the resin-filler interface. Copyright 1999 Kluwer Academic Publishers

  11. Gene Expression Profiling of the Intact Dermal Sheath Cup of Human Hair Follicles.

    Science.gov (United States)

    Niiyama, Shiro; Ishimatsu-Tsuji, Yumiko; Nakazawa, Yosuke; Yoshida, Yuzo; Soma, Tsutomu; Ideta, Ritsuro; Mukai, Hideki; Kishimoto, Jiro

    2018-04-24

    Cells that constitute the dermal papillae of hair follicles might be derived from the dermal sheath, the peribulbar component of which is the dermal sheath cup. The dermal sheath cup is thought to include the progenitor cells of the dermal papillae and possesses hair inductive potential; however, it has not yet been well characterized. This study investigated the gene expression profile of the intact dermal sheath cup, and identified dermal sheath cup signature genes, including extracellular matrix components and BMP-binding molecules, as well as TGF-b1 as an upstream regulator. Among these, GREM2, a member of the BMP antagonists, was found by in situ hybridization to be highly specific to the dermal sheath cup, implying that GREM2 is a key molecule contributing to maintenance of the properties of the dermal sheath cup.

  12. Autonomous Slat-Cove-Filler Device for Reduction of Aeroacoustic Noise Associated with Aircraft Systems

    Science.gov (United States)

    Turner, Travis L. (Inventor); Kidd, Reggie T. (Inventor); Lockard, David P (Inventor); Khorrami, Mehdi R. (Inventor); Streett, Craig L. (Inventor); Weber, Douglas Leo (Inventor)

    2016-01-01

    A slat cove filler is utilized to reduce airframe noise resulting from deployment of a leading edge slat of an aircraft wing. The slat cove filler is preferably made of a super elastic shape memory alloy, and the slat cove filler shifts between stowed and deployed shapes as the slat is deployed. The slat cove filler may be configured such that a separate powered actuator is not required to change the shape of the slat cove filler from its deployed shape to its stowed shape and vice-versa. The outer contour of the slat cove filler preferably follows a profile designed to maintain accelerating flow in the gap between the slat cove filler and wing leading edge to provide for noise reduction.

  13. Fine needle aspiration cytology of dermal cylindroma

    Directory of Open Access Journals (Sweden)

    Parikshaa Gupta

    2014-01-01

    Full Text Available In this paper, we have described fine needle aspiration cytology (FNAC of a rare case of dermal cylindroma. A 40-year-old female presented with a lateral mid-cervical swelling fixed to the skin. FNAC smears showed multiple clusters of small, round to oval cells with hyperchromatic nuclei, inconspicuous nucleoli and scant cytoplasm. In addition, the background showed deposits of basement membrane type material. This was dark magenta colored pinkish globular material. The globules were occasionally surrounded by the basal type of cells. Occasional cells with elongated nuclei were also noted. Cytological diagnosis of skin adnexal tumor possibly cylindroma was offered. Subsequent histopathology of the swelling showed sheets and clusters of cells in a jigsaw puzzle-like fashion. Deposition of abundant basement membrane-like material was noted in between the tumor cells. A diagnosis of cylindorma was offered. FNAC along with the subcutaneous location of the tumor and absence of primary salivary gland tumor may help to diagnose such rare case.

  14. Ductility dip cracking susceptibility of Inconel Filler Metal 52 and Inconel Alloy 690

    International Nuclear Information System (INIS)

    Kikel, J.M.; Parker, D.M.

    1998-01-01

    Alloy 690 and Filler Metal 52 have become the materials of choice for commercial nuclear steam generator applications in recent years. Filler Metal 52 exhibits improved resistance to weld solidification and weld-metal liquation cracking as compared to other nickel-based filler metals. However, recently published work indicates that Filler Metal 52 is susceptible to ductility dip cracking (DDC) in highly restrained applications. Susceptibility to fusion zone DDC was evaluated using the transverse varestraint test method, while heat affected zone (HAZ) DDC susceptibility was evaluated using a newly developed spot-on-spot varestraint test method. Alloy 690 and Filler Metal 52 cracking susceptibility was compared to the DDC susceptibility of Alloy 600, Filler Metal 52, and Filler Metal 625. In addition, the effect of grain size and orientation on cracking susceptibility was also included in this study. Alloy 690, Filler Metal 82, Filler Metal 52, and Filler Metal 625 were found more susceptible to fusion zone DDC than Alloy 600. Filler Metal 52 and Alloy 690 were found more susceptible to HAZ DDC when compared to wrought Alloy 600, Filler Metal 82 and Filler Metal 625. Filler Metal 52 exhibited the greatest susceptibility to HAZ DDC of all the weld metals evaluated. The base materials were found much more resistant to HAZ DDC in the wrought condition than when autogenously welded. A smaller grain size was found to offer greater resistance to DDC. For weld metal where grain size is difficult to control, a change in grain orientation was found to improve resistance to DDC

  15. Treatment of facial atrophic scars with Esthélis, a hyaluronic acid filler with polydense cohesive matrix (CPM).

    Science.gov (United States)

    Hasson, Ariel; Romero, William A

    2010-12-01

    The treatment of atrophic scars is difficult and dermal filler materials provide a simple alternative with immediate results. Esthélis® is an injectable non-animal crosslinked hyaluronic acid of Swiss origin characterized by a polydense cohesive matrix (CPM®) which produces a gel of uniform consistency with better biointegration to the tissues and a longer duration. To evaluate Esthélis in the treatment of atrophic scars. Twelve patients aged 18-56 years with facial atrophic scars caused by acne vulgaris, dog bite, piercing, basal cell carcinoma and leishmaniasis were treated with Esthélis. The injection technique was linear threading, serial puncture or a combination of both. Clinical efficacy was assessed independently by the authors and by patients immediately, one week and one month after the injection. Adverse events were registered. Authors described the results as moderate (27%), good (57%) and excellent (17%), immediately, one week and one month after the injection. Patients evaluated the cosmetic improvement as good (42%) or excellent (58%) one month after the treatment. Pain during the injection was described as slight or moderate. Only mild erythema was observed immediately after injection, which spontaneously resolved within few hours. Esthélis showed good or excellent results in most patients with atrophic scars, and these were perceived as even better when patients evaluated the cosmetic improvement. The best results were observed in patients with more deforming scars such as surgical scars or trauma.

  16. Filler segmentation of SEM paper images based on mathematical morphology.

    Science.gov (United States)

    Ait Kbir, M; Benslimane, Rachid; Princi, Elisabetta; Vicini, Silvia; Pedemonte, Enrico

    2007-07-01

    Recent developments in microscopy and image processing have made digital measurements on high-resolution images of fibrous materials possible. This helps to gain a better understanding of the structure and other properties of the material at micro level. In this paper SEM image segmentation based on mathematical morphology is proposed. In fact, paper models images (Whatman, Murillo, Watercolor, Newsprint paper) selected in the context of the Euro Mediterranean PaperTech Project have different distributions of fibers and fillers, caused by the presence of SiAl and CaCO3 particles. It is a microscopy challenge to make filler particles in the sheet distinguishable from the other components of the paper surface. This objectif is reached here by using switable strutural elements and mathematical morphology operators.

  17. Utilization of Durian Seed Flour as Filler Ingredient of Meatball

    OpenAIRE

    D. R. Malini; I. I. Arief; H. Nuraini

    2016-01-01

    Durian seed flour contains starch consisted of amylose and amylopectin like tapioca flour, so it can be utilized as a filler in meatball production. The purposes of this research were to evaluate the nutrient content and quality of durian seed flour, the best level of durian seed flour addition to the meatball production, and the quality of beef meatball during storage in room temperature and refrigerator. Complete randomized design (CRD) was used with 3 treatments and 3 replications. The tre...

  18. Evaluation of rice husk ash as filler in tread compounds

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, M. R. S., E-mail: monica.fernandes@lanxess.com [Lanxess Elastômeros do Brasil S.A., Brasil and Instituto de Química, Universidade do Estado do Rio de Janeiro (UERJ) (Brazil); Furtado, C. R. G., E-mail: russi@globo.com, E-mail: ana.furtado.sousa@gmail.com; Sousa, A. M. F. de, E-mail: russi@globo.com, E-mail: ana.furtado.sousa@gmail.com [Instituto de Química, Universidade do Estado do Rio de Janeiro (UERJ) (Brazil)

    2014-05-15

    Rice which is one of the largest agriculture crops produces around 22% of rice rusk during its milling process. This material is mainly used as fuel for energy generation, which results in an ash, which disposal represents an environmental issue. The rice husk ash (RHA) contains over than 70% of silica in an amorphous form and a lot of applications is being developed for it all over the world. The use of silica as a filler in the tire industry is growing since it contributes significantly to the reduction of fuel consumption of the automobiles, allowing at the same time better traction (safety). This paper presents an evaluation of the use of RHA as filler in rubber tread compounds prepared in lab scale and compares its performance with compounds prepared with commercial silica and carbon black, the fillers normally used in tire industry. Mechanical and rheological properties are evaluated, with emphasis for tan delta as an indicator of tread performance related with rolling resistance (fuel consumption) and wet grip/traction (safety)

  19. Utilization of Durian Seed Flour as Filler Ingredient of Meatball

    Directory of Open Access Journals (Sweden)

    D. R. Malini

    2016-12-01

    Full Text Available Durian seed flour contains starch consisted of amylose and amylopectin like tapioca flour, so it can be utilized as a filler in meatball production. The purposes of this research were to evaluate the nutrient content and quality of durian seed flour, the best level of durian seed flour addition to the meatball production, and the quality of beef meatball during storage in room temperature and refrigerator. Complete randomized design (CRD was used with 3 treatments and 3 replications. The treatments used different filler ingredients consisted of: 1 100% tapioca, 2 50% tapioca + 50% durian seed flour, and 3 100% durian seed flour utilization. The results showed that durian seed flour could affect the protein levels and hardness of beef meatballs. In the organoleptic test, the addition of durian seed flour had no effect on the appearance of the color, flavor, aroma, and texture. The meatballs with 100% durian seed flour had the lowest hardness. The protein content of the meatballs with 100% durian seed flour was the highest. The used of 50% durian seed flour gave the best effect to beef meatball during storage. Meatball could be stored up to 8 h in room temperature while refrigerator could keep it longer up to 12 d. It was concluded that the addition 50% durian seed flour may substitute tapioca flour as filler ingredient of beef meatball.

  20. Evaluation of rice husk ash as filler in tread compounds

    International Nuclear Information System (INIS)

    Fernandes, M. R. S.; Furtado, C. R. G.; Sousa, A. M. F. de

    2014-01-01

    Rice which is one of the largest agriculture crops produces around 22% of rice rusk during its milling process. This material is mainly used as fuel for energy generation, which results in an ash, which disposal represents an environmental issue. The rice husk ash (RHA) contains over than 70% of silica in an amorphous form and a lot of applications is being developed for it all over the world. The use of silica as a filler in the tire industry is growing since it contributes significantly to the reduction of fuel consumption of the automobiles, allowing at the same time better traction (safety). This paper presents an evaluation of the use of RHA as filler in rubber tread compounds prepared in lab scale and compares its performance with compounds prepared with commercial silica and carbon black, the fillers normally used in tire industry. Mechanical and rheological properties are evaluated, with emphasis for tan delta as an indicator of tread performance related with rolling resistance (fuel consumption) and wet grip/traction (safety)

  1. Braze welding of cobalt with a silver–copper filler

    Directory of Open Access Journals (Sweden)

    Everett M. Criss

    2015-01-01

    Full Text Available A new method of joining cobalt by braze-welding it with a silver–copper filler was developed in order to better understand the residual stresses in beryllium–aluminum/silicon weldments which are problematic to investigate because of the high toxicity of Be. The base and filler metals of this new welding system were selected to replicate the physical properties, crystal structures, and chemical behavior of the Be–AlSi welds. Welding parameters of this surrogate Co–AgCu system were determined by experimentation combining 4-point bending tests and microscopy. Final welds are 5 pass manual TIG (tungsten inert gas, with He top gas and Ar back gas. Control of the welding process produces welds with full penetration melting of the cobalt base. Microscopy indicates that cracking is minimal, and not through thickness, whereas 4-point bending shows failure is not by base-filler delamination. These welds improve upon the original Be–AlSi welds, which do not possess full penetration, and have considerable porosity. We propose that utilization of our welding methods will increase the strength of the Be–AlSi weldments. The specialized welding techniques developed for this study may be applicable not only for the parent Be–AlSi welds, but to braze welds and welds utilizing brittle materials in general. This concept of surrogacy may prove useful in the study of many different types of exotic welds.

  2. Lymphedema Fat Graft: An Ideal Filler for Facial Rejuvenation

    Directory of Open Access Journals (Sweden)

    Fabio Nicoli

    2014-09-01

    Full Text Available Lymphedema is a chronic disorder characterized by lymph stasis in the subcutaneous tissue. Lymphatic fluid contains several components including hyaluronic acid and has many important properties. Over the past few years, significant research has been performed to identify an ideal tissue to implant as a filler. Because of its unique composition, fat harvested from the lymphedema tissue is an interesting topic for investigation and has significant potential for application as a filler, particularly in facial rejuvenation. Over a 36-month period, we treated and assessed 8 patients with lymphedematous limbs who concurrently underwent facial rejuvenation with lymphedema fat (LF. We conducted a pre- and post-operative satisfaction questionnaire survey and a histological assessment of the harvested LF fat. The overall mean general appearance score at an average of 6 months after the procedure was 7.2±0.5, demonstrating great improvement. Patients reported significant improvement in their skin texture with a reading of 8.5±0.7 and an improvement in their self-esteem. This study demonstrates that LF as an ideal autologous injectable filler is clinically applicable and easily available in patients with lymphedema. We recommend the further study and clinical use of this tissue as it exhibits important properties and qualities for future applications and research.

  3. Melanogenesis in dermal melanocytes of Japanese Silky chicken embryos.

    Science.gov (United States)

    Ortolani-Machado, C F; Freitas, P F; Faraco, C D

    2009-08-01

    The Japanese Silky chicken (SK) shows dermal and visceral hyperpigmentation. This study characterizes ultrastructurally the melanin granules developing in dermal melanocytes of the dorsal skin of SK, in an attempt to better understand the processes of melanogenesis in these permanently ectopic cells. The steps of melanogenesis are similar to those described for epidermal melanocytes, with melanosomes going from stage I to IV but, in SK, the maturation occurs in the cell body, as well as in the cytoplasmic processes. At stage III, the deposition of melanin is cumulative and can aggregate in rounded structures, which combine to turn into the mature granule. The final destiny of mature melanosomes is still unclear, although it was observed that dermal macrophages can accumulate melanin granules in their phagosomes. Even with the close proximity between melanocytes and other dermal cells, the transference of melanosomes was not observed. Our findings indicate that melanogenesis in dermal melanocytes in SK has the same morphological characteristics found in epidermal melanocytes, but the functional aspect still remains to be elucidated.

  4. DermAll nanomedicine for allergen-specific immunotherapy.

    Science.gov (United States)

    Garaczi, Edina; Szabó, Kornélia; Francziszti, László; Csiszovszki, Zsolt; Lőrincz, Orsolya; Tőke, Enikő R; Molnár, Levente; Bitai, Tamás; Jánossy, Tamás; Bata-Csörgő, Zsuzsanna; Kemény, Lajos; Lisziewicz, Julianna

    2013-11-01

    Allergen-specific immunotherapy (ASIT) the only disease-modifying treatment for IgE-mediated allergies is characterized with long treatment duration and high risk of side effects. We investigated the safety, immunogenicity and efficacy of a novel ASIT, called DermAll, in an experimental allergic rhinitis model. We designed and characterized DermAll-OVA, a synthetic plasmid pDNA/PEIm nanomedicine expressing ovalbumin (OVA) as model allergen. DermAll-OVA was administered topically with DermaPrep device to target Langerhans cells. To detect the clinical efficacy of DermAll ASIT we quantified the nasal symptoms and characterized the immunomodulatory activity of DermAll ASIT by measuring cytokine secretion after OVA-stimulation of splenocytes and antibodies from the sera. In allergic mice DermAll ASIT was as safe as Placebo, balanced the allergen-induced pathogenic TH2-polarized immune responses, and decreased the clinical symptoms by 52% [32%, 70%] compared to Placebo. These studies suggest that DermAll ASIT is safe and should significantly improve the immunopathology and symptoms of allergic diseases. A novel allergen-specific immunotherapy for IgE-mediated allergies is presented in this paper, using an experimental allergic rhinitis model and a synthetic plasmid pDNA/PEIm nanomedicine expressing ovalbumin as model allergen. Over 50% reduction of symptoms was found as the immune system's balance was favorably altered toward more TH2-polarized immune responses. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Measurements of Dermal and Oral Emissions from Humans

    DEFF Research Database (Denmark)

    Tsushima, Sayana; Bekö, Gabriel; Bossi, Rossana

    2016-01-01

    Human related pollutants (bioeffluents) emitted through skin and via exhaled breath were measured. Two climate chambers were connected via flexible ducts. The ducts were in one chamber attached to a breathing mask, through which five subjects exhaled on one occasion the air into the other chamber......: Human bioeffluents emitted orally were in this way isolated from those that were emitted dermally. On another occasion, the subjects exhaled the air into the chamber where they were sitting, thus exposure contained oral and dermal bioeffluents. Another twenty subjects assessed the air quality...... in the chambers. They judged the air quality in the chamber with dermal bioeffluents to be lower than in the one containing orally exhaled bioeffluents, and similar to the air quality in the chamber with all bioeffluents. The chemical compounds with slightly elevated concentrations differed between the two...

  6. INVIVO DEGRADATION OF PROCESSED DERMAL SHEEP COLLAGEN EVALUATED WITH TRANSMISSION ELECTRON-MICROSCOPY

    NARCIS (Netherlands)

    VANWACHEM, PB; VANLUYN, MJA; NIEUWENHUIS, P; KOERTEN, HK; DAMINK, LO; TENHOOPEN, H; FEIJEN, J

    The in vivo degradation of hexamethylenediisocyanate-tanned dermal sheep collagen was studied with transmission electron microscopy. Discs of hexamethylenediisocyanate-tanned dermal sheep collagen were subcutaneously implanted in rats. Both an intra- and an extracellular route of degradation could

  7. In vivo degradation of processed dermal sheep collagen evaluated with transmission electron microscopy

    NARCIS (Netherlands)

    van Wachem, P.B.; van Luyn, M.J.A.; Nieuwenhuis, P.; Koerten, H.K.; Olde damink, L.H.H.; Olde-Damink, L.; ten Hoopen, Hermina W.M.; Feijen, Jan

    1991-01-01

    The in vivo degradation of hexamethylenediisocyanate-tanned dermal sheep collagen was studied with transmission electron microscopy. Discs of hexamethylenediisocyanate-tanned dermal sheep collagen were subcutaneously implanted in rats. Both an intra- and an extracellular route of degradation could

  8. Blaschko Linear Enamel Defects - A Marker for Focal Dermal Hypoplasia: Case Report of Focal Dermal Hypoplasia

    Directory of Open Access Journals (Sweden)

    Stefan Gysin

    2015-05-01

    Full Text Available Focal dermal hypoplasia (FDH is a rare genetic skin disorder. The inheritance of FDH or Goltz-Gorlin syndrome is X-linked dominant and the disease is associated with a PORCN gene mutation. This gene plays a key role in the Wnt pathway, which has an impact on embryonic development. Every tissue derived from meso- and ectoderm can be affected. Patients suffer from cutaneous, ocular, osseous, oral and dental defects. The skin and dental alterations manifest along the Blaschko lines. We present a woman (born in 1962 suffering from FDH with congenital skin changes and Blaschko linear enamel defects. Typical symptoms (e.g. fat herniations, scoliosis, syndactyly, microphthalmia, caries and alopecia plus vertical grooving of all teeth gave a first indication. Molecular genetic testing confirmed the definitive diagnosis of FDH. We hypothesize that, in the context of typical skin changes, visible Blaschko lines on the teeth in the form of vertical grooves are almost pathognomonic for FDH.

  9. Skin Necrosis with Oculomotor Nerve Palsy Due to a Hyaluronic Acid Filler Injection

    Directory of Open Access Journals (Sweden)

    Jae Il Lee

    2017-07-01

    Full Text Available Performing rhinoplasty using filler injections, which improve facial wrinkles or soft tissues, is relatively inexpensive. However, intravascular filler injections can cause severe complications, such as skin necrosis and visual loss. We describe a case of blepharoptosis and skin necrosis caused by augmentation rhinoplasty and we discuss the patient’s clinical progress. We describe the case of a 25-year-old female patient who experienced severe pain, blepharoptosis, and decreased visual acuity immediately after receiving a filler injection. Our case suggests that surgeons should be aware of nasal vascularity before performing an operation, and that they should avoid injecting fillers at a high pressure and/or in excessive amounts. Additionally, filler injections should be stopped if the patient complains of severe pain, and appropriate measures should be taken to prevent complications caused by intravascular filler injections.

  10. EFFECT OF FILLER LOADING ON PHYSICAL AND FLEXURAL PROPERTIES OF RAPESEED STEM/PP COMPOSITES

    Directory of Open Access Journals (Sweden)

    Seyed Majid Zabihzadeh

    2011-03-01

    Full Text Available The objective of the study is to develop a new filler for the production of natural filler thermoplastic composites using the waste rapeseed stalks. The long-term water absorption and thickness swelling behaviors and flexural properties of rapeseed filled polypropylene (PP composites were investigated. Three different contents of filler were tested: 30, 45, and 60 wt%. Results of long-term hygroscopic tests indicated that by the increase in filler content from 30% to 60%, water diffusion absorption and thickness swelling rate parameter increased. A swelling model developed by Shi and Gardner can be used to quantify the swelling rate. The increasing of filler content reduced the flexural strength of the rapeseed/PP composites significantly. In contrast to the flexural strength, the flexural modulus improved with increasing the filler content. The flexural properties of these composites were decreased after the water uptake, due to the effect of the water molecules.

  11. Cleft Palate Fistula Closure Utilizing Acellular Dermal Matrix.

    Science.gov (United States)

    Emodi, Omri; Ginini, Jiriys George; van Aalst, John A; Shilo, Dekel; Naddaf, Raja; Aizenbud, Dror; Rachmiel, Adi

    2018-03-01

    Fistulas represent failure of cleft palate repair. Secondary and tertiary fistula repair is challenging, with high recurrence rates. In the present retrospective study, we review the efficacy of using acellular dermal matrix as an interposition layer for cleft palate fistula closure in 20 consecutive patients between 2013 and 2016. Complete fistula closure was obtained in 16 patients; 1 patient had asymptomatic recurrent fistula; 2 patients had partial closure with reduction of fistula size and minimal nasal regurgitation; 1 patient developed a recurrent fistula without changes in symptoms (success rate of 85%). We conclude that utilizing acellular dermal matrix for cleft palate fistula repair is safe and simple with a high success rate.

  12. Labeled chloroquine analog in diagnosis of ocular and dermal melanomas

    International Nuclear Information System (INIS)

    Beierwaltes, W.H.

    1974-01-01

    On the basis of the melanin-specific properties of chloroquine, an 125 I-labeled chloroquine analog (NM-113) was synthesized for use in the diagnosis of ocular and dermal melanomas. The limitations and indications for the use of NM-113 in the diagnosis of dermal melanomas are summarized, and its efficiency in the diagnosis of ocular melanomas is discussed. The low probability of side effects (radiation effects) on the retina from a diagnostic dose of 2 m Ci (46 rads) is mentioned. (U.S.)

  13. Novel Double-Needle System That Can Prevent Intravascular Injection of Any Filler

    Directory of Open Access Journals (Sweden)

    Hsiang Huang, MD

    2017-09-01

    Full Text Available Summary:. A new type of needle system combines 2 parts, an inner needle and an outer needle. The inner needle is used for filler injection and the outer needle acts as a guiding needle that can observe blood reflow when inserting into the vessel lumen during injection process. This new needle system can be used for all kinds of filler, providing real time monitoring for physician and preventing intravascular injection of any filler.

  14. Dermal reflectivity determined by optical coherence tomography is an indicator of epidermal hyperplasia and dermal edema within inflamed skin

    Science.gov (United States)

    Phillips, Kevin G.; Wang, Yun; Levitz, David; Choudhury, Niloy; Swanzey, Emily; Lagowski, James; Kulesz-Martin, Molly; Jacques, Steven L.

    2011-04-01

    Psoriasis is a common inflammatory skin disease resulting from genetic and environmental alterations of cutaneous immune responses. While numerous therapeutic targets involved in the immunopathogenesis of psoriasis have been identified, the in vivo dynamics of inflammation in psoriasis remain unclear. We undertook in vivo time course focus-tracked optical coherence tomography (OCT) imaging to noninvasively document cutaneous alterations in mouse skin treated topically with Imiquimod (IMQ), an established model of a psoriasis-like disease. Quantitative appraisal of dermal architectural changes was achieved through a two parameter fit of OCT axial scans in the dermis of the form A(x, y, z) = ρ(x, y)exp [ - μ(x, y)z]. Ensemble averaging over 2000 axial scans per mouse in each treatment arm revealed no significant changes in the average dermal attenuation rate, , however the average local dermal reflectivity , decreased significantly following 1, 3, and 6 days of IMQ treatment (p humans.

  15. Relative absorption and dermal loading of chemical substances: Consequences for risk assessment

    NARCIS (Netherlands)

    Buist, H.E.; Schaafsma, G.; Sandt, J.J.M. van de

    2009-01-01

    Quantification of skin absorption is an essential step in reducing the uncertainty of dermal risk assessment. Data from literature indicate that the relative dermal absorption of substances is dependent on dermal loading. Therefore, an internal exposure calculated with absorption data determined at

  16. Validation of the dermal exposure model in ECETOC TRA.

    Science.gov (United States)

    Marquart, Hans; Franken, Remy; Goede, Henk; Fransman, Wouter; Schinkel, Jody

    2017-08-01

    The ECETOC TRA model (presently version 3.1) is often used to estimate worker inhalation and dermal exposure in regulatory risk assessment. The dermal model in ECETOC TRA has not yet been validated by comparison with independent measured exposure levels. This was the goal of the present study. Measured exposure levels and relevant contextual information were gathered via literature search, websites of relevant occupational health institutes and direct requests for data to industry. Exposure data were clustered in so-called exposure cases, which are sets of data from one data source that are expected to have the same values for input parameters in the ECETOC TRA dermal exposure model. For each exposure case, the 75th percentile of measured values was calculated, because the model intends to estimate these values. The input values for the parameters in ECETOC TRA were assigned by an expert elicitation and consensus building process, based on descriptions of relevant contextual information.From more than 35 data sources, 106 useful exposure cases were derived, that were used for direct comparison with the model estimates. The exposure cases covered a large part of the ECETOC TRA dermal exposure model. The model explained 37% of the variance in the 75th percentiles of measured values. In around 80% of the exposure cases, the model estimate was higher than the 75th percentile of measured values. In the remaining exposure cases, the model estimate may not be sufficiently conservative.The model was shown to have a clear bias towards (severe) overestimation of dermal exposure at low measured exposure values, while all cases of apparent underestimation by the ECETOC TRA dermal exposure model occurred at high measured exposure values. This can be partly explained by a built-in bias in the effect of concentration of substance in product used, duration of exposure and the use of protective gloves in the model. The effect of protective gloves was calculated to be on average a

  17. B218 Weld Filler Wire Characterization for Al-Li Alloy 2195

    Science.gov (United States)

    Bjorkman, Gerry; Russell, Carolyn

    2000-01-01

    NASA Marshall Space Flight Center, Lockheed Martin Space Systems- Michoud Operations, and McCook Metals have developed an aluminum-copper weld filler wire for fusion welding aluminum lithium alloy 2195. The aluminum-copper based weld filler wire has been identified as B218, a McCook Metals designation. B218 is the result of six years of weld filler wire development funded by NASA, Lockheed Martin, and McCook Metals. The filler wire chemistry was developed to produce enhanced 2195 weld and repair weld mechanical properties over the 4043 aluminum-silicon weld filler wire, which is currently used to weld 2195 on the Super Lightweight External Tank for the NASA Space Shuttle Program. An initial characterization was performed consisting of a repair weld evaluation using B218 and 4043 weld filler wires. The testing involved room temperature and cryogenic repair weld tensile testing along with fracture toughness testing. From the testing, B218 weld filler wire produce enhanced repair weld tensile strength, ductility, and fracture properties over 4043. B218 weld filler wire has proved to be a superior weld filler wire for welding aluminum lithium alloy 2195 over 4043.

  18. Stress-Strain Relation of Tire Rubber Consist of Entangled Polymers, Fillers and Crosslink

    Science.gov (United States)

    Hagita, Katsumi; Bito, Y.; Minagawa, Y.; Omiya, M.; Morita, H.; Doi, M.; Takano, H.

    2009-03-01

    We presented a preliminary result of large scale coarse-grained Molecular Dynamics simulation of filled polymer melts with Sulfur-crosslink under an uni-axial deformation by using the Kremer-Grest Model. The size of simulation box under periodic boundary conditions (PBC) is set to about 66nm to consider length of entangled polymer chains, size and structure of fillers, and non-uniform distribution of crosslink. We put 640 polymer chains of 1024 particles and 32 fillers into the PBC box. Each filler consists of 1280 particles of the C1280 fullerene structure. A repulsive force from the center of the filler is applied to the particles. Here, the particles of the fillers are chosen to be the same as the particles of the polymers and the diameter of the filler is about 15nm. The distribution of the fillers used in this simulation is provided by the result of 2d pattern RMC analysis for 2D-USAXS experiments at SPring-8. Sulfur crosslink are randomly distributed in the system. It is found that stress-strain curves estimated by applying a certain uni-axial deformation to the system in simulations are in good agreement with those in experiments. It is successful to show difference on the S-S curve between existence / absence of fillers and qualitative dependence of attractive force between polymer and filler.

  19. Suspect filler similarity in eyewitness lineups: a literature review and a novel methodology.

    Science.gov (United States)

    Fitzgerald, Ryan J; Oriet, Chris; Price, Heather L

    2015-02-01

    Eyewitness lineups typically contain a suspect (guilty or innocent) and fillers (known innocents). The degree to which fillers should resemble the suspect is a complex issue that has yet to be resolved. Previously, researchers have voiced concern that eyewitnesses would be unable to identify their target from a lineup containing highly similar fillers; however, our literature review suggests highly similar fillers have only rarely been shown to have this effect. To further examine the effect of highly similar fillers on lineup responses, we used morphing software to create fillers of moderately high and very high similarity to the suspect. When the culprit was in the lineup, a higher correct identification rate was observed in moderately high similarity lineups than in very high similarity lineups. When the culprit was absent, similarity did not yield a significant effect on innocent suspect misidentification rates. However, the correct rejection rate in the moderately high similarity lineup was 20% higher than in the very high similarity lineup. When choosing rates were controlled by calculating identification probabilities for only those who made a selection from the lineup, culprit identification rates as well as innocent suspect misidentification rates were significantly higher in the moderately high similarity lineup than in the very high similarity lineup. Thus, very high similarity fillers yielded costs and benefits. Although our research suggests that selecting the most similar fillers available may adversely affect correct identification rates, we recommend additional research using fillers obtained from police databases to corroborate our findings.

  20. Effect of mechanical properties of fillers on the grindability of composite resin adhesives.

    Science.gov (United States)

    Iijima, Masahiro; Muguruma, Takeshi; Brantley, William A; Yuasa, Toshihiro; Uechi, Jun; Mizoguchi, Itaru

    2010-10-01

    The purpose of this study was to investigate the effect of filler properties on the grindability of composite resin adhesives. Six composite resin products were selected: Transbond XT (3M Unitek, Monrovia, Calif), Transbond Plus (3M Unitek), Enlight (Ormco, Glendora, Calif), Kurasper F (Kuraray Medical, Tokyo, Japan), Beauty Ortho Bond (Shofu, Kyoto, Japan), and Beauty Ortho Bond Salivatect (Shofu). Compositions and weight fractions of fillers were determined by x-ray fluorescence analysis and ash test, respectively. The polished surface of each resin specimen was examined with a scanning electron microscope. Vickers hardness of plate specimens (15 × 10 × 3 mm) was measured, and nano-indentation was performed on large filler particles (>10 μm). Grindability for a low-speed tungsten-carbide bur was estimated. Data were compared with anlaysis of variance (ANOVA) and the Tukey multiple range test. Relationships among grindability, filler content, filler nano-indentation hardness (nano-hardness), filler elastic modulus, and Vickers hardness of the composite resins were investigated with the Pearson correlation coefficient test. Morphology and filler size of these adhesives showed great variations. The products could be divided into 2 groups, based on composition, which affected grindability. Vickers hardness of the adhesives did not correlate (r = 0.140) with filler nano-hardness, which showed a significant negative correlation (r = -0.664) with grindability. Filler nano-hardness greatly influences the grindability of composite resin adhesives. Copyright © 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  1. Improvement of Scratch and Wear Resistance of Polymers by Fillers Including Nanofillers

    Directory of Open Access Journals (Sweden)

    Witold Brostow

    2017-03-01

    Full Text Available Polymers have lower resistance to scratching and wear than metals. Liquid lubricants work well for metals but not for polymers nor for polymer-based composites (PBCs. We review approaches for improvement of tribological properties of polymers based on inclusion of fillers. The fillers can be metallic or ceramic—with obvious consequences for electrical resistivity of the composites. Distinctions between effectiveness of micro- versus nano-particles are analyzed. For example, aluminum nanoparticles as filler are more effective for property improvement than microparticles at the same overall volumetric concentration. Prevention of local agglomeration of filler particles is discussed along with a technique to verify the prevention.

  2. Moessbauer study of the magnetic filler for suppositories

    International Nuclear Information System (INIS)

    Bykov, A.V.; Nikolaev, V.I.; Shulgin, V.I.; Diaz, C.; Kharitonov, Yu.Ya.; Cherkasova, O.G.

    1991-01-01

    Moessbauer spectroscopy methods are discussed when applied to test the properties of magnetic suppositories used in medicine. The experiments were carried out on magnetic rectal suppositories containing paramadine and fine-dispersed ferrite powder (BaO.nFe 2 O 3 ) as a magnetic filler. According to the data on the value of effective magnetic field on 57 Fe nuclei in ferrite magnetic sublattices, the stoichiometric n-number equals approximately 5.5; this value corresponds to the composition range of optimal magnetic properties. (orig.)

  3. Moessbauer study of the magnetic filler for suppositories

    Energy Technology Data Exchange (ETDEWEB)

    Bykov, A.V.; Nikolaev, V.I.; Shulgin, V.I. (M.V. Lomonosov Moscow State Univ. (USSR)); Diaz, C. (Cuba National Center of Scientific Research, Havana (Cuba)); Kharitonov, Yu.Ya.; Cherkasova, O.G. (I.M. Sechenov First Moscow Medical Inst. (USSR))

    1991-11-01

    Moessbauer spectroscopy methods are discussed when applied to test the properties of magnetic suppositories used in medicine. The experiments were carried out on magnetic rectal suppositories containing paramadine and fine-dispersed ferrite powder (BaO.nFe[sub 2]O[sub 3]) as a magnetic filler. According to the data on the value of effective magnetic field on [sup 57]Fe nuclei in ferrite magnetic sublattices, the stoichiometric n-number equals approximately 5.5; this value corresponds to the composition range of optimal magnetic properties. (orig.).

  4. Epoxy composites based on inexpensive tire waste filler

    Science.gov (United States)

    Ahmetli, Gulnare; Gungor, Ahmet; Kocaman, Suheyla

    2014-05-01

    Tire waste (TW) was recycled as raw material for the preparation of DGEBA-type epoxy composite materials. The effects of filler amount and epoxy type on the mechanical properties of the composites were investigated. Tensile strength and Young's modulus of the composites with NPEL were generally higher than composites with NPEF. The appropriate mass level for TW in both type composites was found to be 20 wt%. The equilibrium water sorption of NPEL/TW and NPEF/TW composites for 14-day immersion was determined as 0.10 % and 0.21 %, respectively. Scanning electron microscopy (SEM) and X-ray diffraction (XRD) were used for characterization of the composites.

  5. Dissecting antigen processing and presentation routes in dermal vaccination strategies

    NARCIS (Netherlands)

    Platteel, Anouk C M; Henri, Sandrine; Zaiss, Dietmar M; Sijts, Alice J A M

    2017-01-01

    The skin is an attractive site for vaccination due to its accessibility and presence of immune cells surveilling this barrier. However, knowledge of antigen processing and presentation upon dermal vaccination is sparse. In this study we determined antigen processing routes that lead to CD8(+) T cell

  6. Estimating dermal transfer from PCB-contaminated porous surfaces.

    Science.gov (United States)

    Slayton, T M; Valberg, P A; Wait, A D

    1998-06-01

    Health risks posed by dermal contact with PCB-contaminated porous surfaces have not been directly demonstrated and are difficult to estimate indirectly. Surface contamination by organic compounds is commonly assessed by collecting wipe samples with hexane as the solvent. However, for porous surfaces, hexane wipe characterization is of limited direct use when estimating potential human exposure. Particularly for porous surfaces, the relationship between the amount of organic material collected by hexane and the amount actually picked up by, for example, a person's hand touch is unknown. To better mimic PCB pickup by casual hand contact with contaminated concrete surfaces, we used alternate solvents and wipe application methods that more closely mimic casual dermal contact. Our sampling results were compared to PCB pickup using hexane-wetted wipes and the standard rubbing protocol. Dry and oil-wetted samples, applied without rubbing, picked up less than 1% of the PCBs picked up by the standard hexane procedure; with rubbing, they picked up about 2%. Without rubbing, saline-wetted wipes picked up 2.5%; with rubbing, they picked up about 12%. While the nature of dermal contact with a contaminated surface cannot be perfectly reproduced with a wipe sample, our results with alternate wiping solvents and rubbing methods more closely mimic hand contact than the standard hexane wipe protocol. The relative pickup estimates presented in this paper can be used in conjunction with site-specific PCB hexane wipe results to estimate dermal pickup rates at sites with PCB-contaminated concrete.

  7. Hydroquinone PBPK model refinement and application to dermal exposure.

    Science.gov (United States)

    Poet, Torka S; Carlton, Betsy D; Deyo, James A; Hinderliter, Paul M

    2010-11-01

    A physiologically based pharmacokinetic (PBPK) model for hydroquinone (HQ) was refined to include an expanded description of HQ-glucuronide metabolites and a description of dermal exposures to support route-to-route and cross-species extrapolation. Total urinary excretion of metabolites from in vivo rat dermal exposures was used to estimate a percutaneous permeability coefficient (K(p); 3.6×10(-5) cm/h). The human in vivo K(p) was estimated to be 1.62×10(-4) cm/h, based on in vitro skin permeability data in rats and humans and rat in vivo values. The projected total multi-substituted glutathione (which was used as an internal dose surrogate for the toxic glutathione metabolites) was modeled following an exposure scenario based on submersion of both hands in a 5% aqueous solution of HQ (similar to black and white photographic developing solution) for 2 h, a worst-case exposure scenario. Total multi-substituted glutathione following this human dermal exposure scenario was several orders of magnitude lower than the internal total glutathione conjugates in rats following an oral exposure to the rat NOEL of 20 mg/kg. Thus, under more realistic human dermal exposure conditions, it is unlikely that toxic glutathione conjugates (primarily the di- and, to a lesser degree, the tri-glutathione conjugate) will reach significant levels in target tissues. Copyright © 2010. Published by Elsevier Ltd.

  8. Differential Apoptosis in Mucosal and Dermal Wound Healing

    Science.gov (United States)

    Johnson, Ariel; Francis, Marybeth; DiPietro, Luisa Ann

    2014-01-01

    Objectives: Dermal and mucosal healing are mechanistically similar. However, scarring and closure rates are dramatically improved in mucosal healing, possibly due to differences in apoptosis. Apoptosis, nature's preprogrammed form of cell death, occurs via two major pathways, extrinsic and intrinsic, which intersect at caspase3 (Casp3) cleavage and activation. The purpose of this experiment was to identify the predominant pathways of apoptosis in mucosal and dermal wound healing. Approach: Wounds (1 mm biopsy punch) were made in the dorsal skin (n=3) or tongue (n=3) of female Balb/C mice aged 6 weeks. Wounds were harvested at 6 h, 24 h, day 3 (D3), D5, D7, and D10. RNA was isolated and analyzed using real time reverse transcriptase–polymerase chain reaction. Expression levels for genes in the intrinsic and extrinsic apoptotic pathways were compared in dermal and mucosal wounds. Results: Compared to mucosal healing, dermal wounds exhibited significantly higher expression of Casp3 (at D5; phealing compared to skin. Conclusion: Expression patterns of key regulators of apoptosis in wound healing indicate that apoptosis occurs predominantly through the intrinsic pathway in the healing mucosa, but predominantly through the extrinsic pathway in the healing skin. The identification of differences in the apoptotic pathways in skin and mucosal wounds may allow the development of therapeutics to improve skin healing. PMID:25493209

  9. Task-based dermal exposure models for regulatory risk assessment

    NARCIS (Netherlands)

    Warren, N.D.; Marquart, H.; Christopher, Y.; Laitinen, J.; Hemmen, J.J. van

    2006-01-01

    The regulatory risk assessment of chemicals requires the estimation of occupational dermal exposure. Until recently, the models used were either based on limited data or were specific to a particular class of chemical or application. The EU project RISKOFDERM has gathered a considerable number of

  10. Dermal uptake of nicotine from air and clothing: Experimental verification

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Morrison, Glenn; Weschler, Charles J.

    2017-01-01

    Studies suggest that dermal uptake of certain semivolatile organic compounds (SVOC) directly from air can be a significant exposure pathway. This has been experimentally confirmed for two phthalates (Weschler et al., 2015). Morrison et al. (2016) showed that clean clothing can impede, while cloth...

  11. Abdominal wall reconstruction using De-epithelialized dermal flap: A ...

    African Journals Online (AJOL)

    Abdominal wall reconstruction using De-epithelialized dermal flap: A new technique. ... Journal of Surgical Technique and Case Report ... Background: Although autogenous materials have been used in abdominal wall hernioplasty for a long time, the introduction of prosthetic materials diminished their popularity. However ...

  12. Implanon sub-dermal implant: an emerging method of contraception ...

    African Journals Online (AJOL)

    Implanon, a single rod sub-dermal implant is a relatively new contraceptive which offers long term reversible contraception for women. This study seeks to determine the safety, efficacy and acceptor characteristics of Implanon at the family planning clinic of University of Ilorin Teaching Hospital (UITH), Ilorin, Nigeria.

  13. Abdominal wall reconstruction using De-epithelialized dermal flap: A ...

    African Journals Online (AJOL)

    Background: Although autogenous materials have been used in abdominal wall hernioplasty for a long time, the introduction of prosthetic materials diminished their popularity. However, these materials may be expensive, inappropriate or unavailable. The aim of this study is to determine the place of de-epithelialized dermal ...

  14. In vivo dermal absorption of pyrethroid pesticides in the rat.

    Science.gov (United States)

    The potential for exposure to pyrethroid pesticides has risen recently because of their increased use. The objective of this study was to examine the in vivo dermal absorption of bifenthrin, deltamethrin and permethrin in the rat. Hair on the dorsal side of anesthetized adult m...

  15. Respiratory and dermal symptoms in Thai nurses using latex products.

    Science.gov (United States)

    Supapvanich, C; Povey, A C; de Vocht, F

    2013-09-01

    Despite known health risks related to the use of powdered latex gloves (PLGs), they are still widely used in hospitals in developing countries due to the high cost of alternatives. To determine the prevalence of dermal and respiratory symptoms associated with latex glove use in nurses in Thailand and evaluate the influence of previously reported occupational risk factors in this population. A cross-sectional study in female nurses working in three Thai hospitals. Participants completed a questionnaire on demographics, occupational and personal history, use of latex products at work and dermal and respiratory symptoms attributed to occupational use of latex gloves. Of 899 nurses, 18% reported health effects attributed to the use of latex products. After adjustment for confounding, occupational risk factors associated with increased reporting of dermal symptoms included wearing more than 15 pairs of PLG per day (odds ratio (OR): 2.10, 95% confidence interval (CI): [1.32-3.34]), using chlorhexidine (OR: 2.07, 95% CI: [1.22-3.52]) and being an operating theatre nurse (OR: 2.46, 95% CI: [1.47-4.12]). Being a labour ward nurse (OR: 3.52, 95% CI: [1.26-9.85]) was the only factor associated with increased reporting of respiratory symptoms. Continuing use of PLGs in Thai nurses is associated with increased prevalence of dermal symptoms compared with data from developed countries. Measures to reduce such health effects are well established and should be considered. Additionally, replacement of chlorhexidine with an alternative detergent seems advisable.

  16. Dextran derivatives modulate collagen matrix organization in dermal equivalent.

    Science.gov (United States)

    Frank, Laetitia; Lebreton-Decoster, Corinne; Godeau, Gaston; Coulomb, Bernard; Jozefonvicz, Jacqueline

    2006-01-01

    Dextran derivatives can protect heparin binding growth factor implied in wound healing, such as transforming growth factor-beta1 (TGF-beta1) and fibroblast growth factor-2 (FGF-2). The first aim of this study was to investigate the effect of these compounds on human dermal fibroblasts in culture with or without TGF-beta1. Several dextran derivatives obtained by substitution of methylcarboxylate (MC), benzylamide (B) and sulphate (Su) groups were used to determine the effects of each compound on fibroblast growth in vitro. The data indicate that sulphate groups are essential to act on the fibroblast proliferation. The dextran derivative LS21 DMCBSu has been chosen to investigate its effect on dermal wound healing process. Fibroblasts cultured in collagenous matrices named dermal equivalent were treated with the bioactive polymer alone or associated to TGF-beta1 or FGF-2. Cross-sections of dermal equivalent observed by histology or immunohistochemistry, demonstrated that the bioactive polymer accelerates the collagen matrices organization and stimulates the human type-III collagen expression. This bioactive polymer induces apoptosis of myofibroblast, property which may be beneficial in treatment of hypertrophic scar. Culture media analyzed by zymography and Western blot showed that this polymer significantly increases the secretion of zymogen and active form of matrix metalloproteinase-2 (MMP-2), involved in granulation tissue formation. These data suggest that this bioactive polymer has properties which may be beneficial in the treatment of wound healing.

  17. Dermal Contributions to Human Interfollicular Epidermal Architecture and Self-Renewal

    Directory of Open Access Journals (Sweden)

    Kynan T. Lawlor

    2015-11-01

    Full Text Available The human interfollicular epidermis is renewed throughout life by populations of proliferating basal keratinocytes. Though interfollicular keratinocyte stem cells have been identified, it is not known how self-renewal in this compartment is spatially organized. At the epidermal-dermal junction, keratinocytes sit atop a heterogeneous mix of dermal cells that may regulate keratinocyte self-renewal by influencing local tissue architecture and signalling microenvironments. Focusing on the rete ridges and complementary dermal papillae in human skin, we review the identity and organisation of abundant dermal cells types and present evidence for interactions between the dermal microenvironment and the interfollicular keratinocytes.

  18. Effect of three filler types on mechanical properties of dental composite

    Directory of Open Access Journals (Sweden)

    Pahlavan A.

    2005-06-01

    Full Text Available Statement of Problem: Despite the improvements achieved in the field of dental composites, their strength, longevity, and service life specially in high stress areas is not confirmed. Finding better fillers can be a promising step in this task. Purpose: The purpose of this study was to investigate the effect of the filler type on the mechanical properties of a new experimental dental composite and compare these with the properties of composite containing conventional glass filler. Materials and Methods: Experimental composites were prepared by mixing silane-treated fillers with monomers, composed of 70% Bis-GMA and 30% TEGDMA by weight. Fillers were different among the groups. Glass, leucite ceramic and lithium disilicate were prepared as different filler types. All three groups contained 73% wt filler. Comphorquinone and amines were chosen as photo initiator system. Post curing was done for all groups. Diametral tensile strength (DTS, flexural strength and flexural modulus were measured and compared among groups. Data were analyzed with SPSS package using one-way ANOVA test with P<0.05 as the limit of significance. Results: The results showed that the stronger ceramic fillers have positive effect on the flexural strength. Ceramic fillers increased the flexural strength significantly. No significant differences could be determined in DTS among the groups. Flexural modulus can be affected and increased by using ceramic fillers. Conclusion: Flexural strength is one of the most significant properties of restorative dental materials. The higher flexural strength and flexural modulus can be achieved by stronger ceramic fillers. Any further investigation in this field would be beneficial in the development of restorative dental materials.

  19. Coarse-grained simulation of polymer-filler blends

    Science.gov (United States)

    Legters, Gregg; Kuppa, Vikram; Beaucage, Gregory; Univ of Dayton Collaboration; Univ of Cincinnati Collaboration

    The practical use of polymers often relies on additives that improve the property of the mixture. Examples of such complex blends include tires, pigments, blowing agents and other reactive additives in thermoplastics, and recycled polymers. Such systems usually exhibit a complex partitioning of the components. Most prior work has either focused on fine-grained details such as molecular modeling of chains at interfaces, or on coarse, heuristic, trial-and-error approaches to compounding (eg: tire industry). Thus, there is a significant gap in our understanding of how complex hierarchical structure (across several decades in length) develops in these multicomponent systems. This research employs dissipative particle thermodynamics in conjunction with a pseudo-thermodynamic parameter derived from scattering experiments to represent polymer-filler interactions. DPD simulations will probe how filler dispersion and hierarchical morphology develops in these complex blends, and are validated against experimental (scattering) data. The outcome of our approach is a practical solution to compounding issues, based on a mutually validating experimental and simulation methodology. Support from the NSF (CMMI-1636036/1635865) is gratefully acknowledged.

  20. Injectable neurotoxins and fillers: there is no free lunch.

    Science.gov (United States)

    Emer, Jason; Waldorf, Heidi

    2011-01-01

    Injection of neurotoxins and filling agents for the treatment of facial aesthetics has increased dramatically during the past few decades due to an increased interest in noninvasive aesthetic improvements. An aging but still youth-oriented population expects effective treatments with minimal recovery time and limited risk of complications. Injectable neurotoxins and soft tissue stimulators and fillers have filled this niche of "lunch-time" procedures. As demand for these procedures has increased, supply has followed with more noncore cosmetic specialty physicians, as well as unsupervised ancillary staff, becoming providers and advertising them as easy fixes. Despite an excellent record of safety and efficacy demonstrated in scores of published studies, injectable agents do carry risks of complications. These procedures require a physician with in-depth knowledge of facial anatomy and injection techniques to ensure patient safety and satisfaction. In general, adverse events are preventable and technique-dependent. Although most adverse events are minor and temporary, more serious complications can occur. The recognition, management, and treatment of poor outcomes are as important as obtaining the best aesthetic results. This review addresses important considerations regarding the complications of injectable neurotoxins and fillers used for "lunch-time" injectable procedures. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Filler metal selection for welding a high nitrogen stainless steel

    Science.gov (United States)

    Du Toit, Madeleine

    2002-06-01

    Cromanite is a high-strength austenitic stainless steel that contains approximately 19% chromium, 10% manganese, and 0.5% nitrogen. It can be welded successfully, but due to the high nitrogen content of the base metal, precautions have to be taken to ensure sound welds with the desired combination of properties. Although no matching filler metals are currently available, Cromanite can be welded using a range of commercially available stainless steel welding consumables. E307 stainless steel, the filler metal currently recommended for joining Cromanite, produces welds with mechanical properties that are generally inferior to those of the base metal. In wear applications, these lower strength welds would probably be acceptable, but in applications where full use is made of the high strength of Cromanite, welds with matching strength levels would be required. In this investigation, two welding consumables, ER2209 (a duplex austenitic-ferritic stainless steel) and 15CrMn (an austenitic-manganese hardfacing wire), were evaluated as substitutes for E307. When used to join Cromanite, 15CrMn produced welds displaying severe nitrogen-induced porosity, and this consumable is therefore not recommended. ER2209, however, outperformed E307, producing sound porosity-free welds with excellent mechanical properties, including high ductility and strength levels exceeding the minimum limits specified for Cromanite.

  2. Facial rejuvenation with fillers: The dual plane technique

    Directory of Open Access Journals (Sweden)

    Giovanni Salti

    2015-01-01

    Full Text Available Background: Facial aging is characterized by skin changes, sagging and volume loss. Volume is frequently addressed with reabsorbable fillers like hyaluronic acid gels. Materials and Methods: From an anatomical point of view, the deep and superficial fat compartments evolve differently with aging in a rather predictable manner. Volume can therefore be restored following a technique based on restoring first the deep volumes and there after the superficial volumes. We called this strategy "dual plane". A series of 147 consecutive patients have been treated with fillers using the dual plane technique in the last five years. Results: An average of 4.25 session per patient has been carried out for a total of 625 treatment sessions. The average total amount of products used has been 12 ml per patient with an average amount per session of 3.75 ml. We had few and limited adverse events with this technique. Conclusion: The dual plane technique is an injection technique based on anatomical logics. Different types of products can be used according to the plane of injection and their rheology in order to obtain a natural result and few side effects.

  3. Technical Note: Filler and superplasticizer usage on high strength concrete

    Directory of Open Access Journals (Sweden)

    Sümer, M.

    2007-08-01

    Full Text Available In this research, the effects of filler (rock-dust usage on high strength concrete have been investigated through lab experiments and some results have been obtained. The experiments involved three series of concrete with different cement proportions of 375 kg/m3, 400 kg/m3, and 425 kg/m3. For each series of concrete, three different groups of samples have been prepared, the first one being the reference concrete which contained 0% chemical admixture and 0% filler, the second one contained 1.5% chemical admixture and 0% filler and finally the last group contained 1.5% chemical admixture and 5% filler to the weight of cement used. The chemical admixture used was a type of Super plasticizer with a brand name of “DARACEM 190”, and the cement used was Ordinary Portland Cement of target compressive strength 42.5 N/mm2, obtained from Nuh Cement Plant. For each batch, Slump Tests and Unit Weight Tests were performed. For each stage and group, two 15 cm cubic samples have been tested for Compressive Strength after being cured in water at 20 ± 2 °C for ages of 3 days, 7 days, 28 and 60 days. The total number of samples was 72. As a result, filler usage was found to reduce the porosity of Concrete, increase the Unit Weight of Concrete, increase the need for water and improve the Compressive Strength Properties of Concrete.En el presente trabajo se estudia la influencia de la utilización de un “filler” (polvo mineral en el comportamiento del hormigón de altas prestaciones. Para ello, se realizan ensayos de laboratorio en los que se emplean tres series de hormigón, cada una con una dosificación de cemento distinta, de 375, 400 y 425 kg/m3. Se preparan tres grupos de probetas de cada serie, el primero o de referencia con 0% de aditivo químico y 0% de “filler”, el segundo con un 1,5% del aditivo químico y 0% de “filler” y el tercero con un 1,5% del aditivo químico y un 5% de “filler” en peso del cemento. Como aditivo se

  4. Age-related disruption of autophagy in dermal fibroblasts modulates extracellular matrix components

    Energy Technology Data Exchange (ETDEWEB)

    Tashiro, Kanae [Skin Research Department, POLA Chemical Industries, Inc., Yokohama (Japan); Division of Pharmaceutical Cell Biology, Graduate School of Pharmaceutical Sciences, Kyushu University, Fukuoka (Japan); Shishido, Mayumi [Skin Research Department, POLA Chemical Industries, Inc., Yokohama (Japan); Fujimoto, Keiko [Division of Pharmaceutical Cell Biology, Graduate School of Pharmaceutical Sciences, Kyushu University, Fukuoka (Japan); Organelle Homeostasis Research Center, Kyushu University, Fukuoka (Japan); Hirota, Yuko [Division of Pharmaceutical Cell Biology, Graduate School of Pharmaceutical Sciences, Kyushu University, Fukuoka (Japan); Yo, Kazuyuki; Gomi, Takamasa [Skin Research Department, POLA Chemical Industries, Inc., Yokohama (Japan); Tanaka, Yoshitaka, E-mail: tanakay@bioc.phar.kyushu-u.ac.jp [Division of Pharmaceutical Cell Biology, Graduate School of Pharmaceutical Sciences, Kyushu University, Fukuoka (Japan); Organelle Homeostasis Research Center, Kyushu University, Fukuoka (Japan)

    2014-01-03

    Highlights: •Autophagosomes accumulate in aged dermal fibroblasts. •Autophagic degradation is impaired in aged dermal fibroblasts. •Autophagy disruption affects extracellular matrix components in dermal fibroblasts. -- Abstract: Autophagy is an intracellular degradative system that is believed to be involved in the aging process. The contribution of autophagy to age-related changes in the human skin is unclear. In this study, we examined the relationship between autophagy and skin aging. Transmission electron microscopy and immunofluorescence microscopy analyses of skin tissue and cultured dermal fibroblasts derived from women of different ages revealed an increase in the number of nascent double-membrane autophagosomes with age. Western blot analysis showed that the amount of LC3-II, a form associated with autophagic vacuolar membranes, was significantly increased in aged dermal fibroblasts compared with that in young dermal fibroblasts. Aged dermal fibroblasts were minimally affected by inhibition of autophagic activity. Although lipofuscin autofluorescence was elevated in aged dermal fibroblasts, the expression of Beclin-1 and Atg5—genes essential for autophagosome formation—was similar between young and aged dermal fibroblasts, suggesting that the increase of autophagosomes in aged dermal fibroblasts was due to impaired autophagic flux rather than an increase in autophagosome formation. Treatment of young dermal fibroblasts with lysosomal protease inhibitors, which mimic the condition of aged dermal fibroblasts with reduced autophagic activity, altered the fibroblast content of type I procollagen, hyaluronan and elastin, and caused a breakdown of collagen fibrils. Collectively, these findings suggest that the autophagy pathway is impaired in aged dermal fibroblasts, which leads to deterioration of dermal integrity and skin fragility.

  5. Age-related disruption of autophagy in dermal fibroblasts modulates extracellular matrix components

    International Nuclear Information System (INIS)

    Tashiro, Kanae; Shishido, Mayumi; Fujimoto, Keiko; Hirota, Yuko; Yo, Kazuyuki; Gomi, Takamasa; Tanaka, Yoshitaka

    2014-01-01

    Highlights: •Autophagosomes accumulate in aged dermal fibroblasts. •Autophagic degradation is impaired in aged dermal fibroblasts. •Autophagy disruption affects extracellular matrix components in dermal fibroblasts. -- Abstract: Autophagy is an intracellular degradative system that is believed to be involved in the aging process. The contribution of autophagy to age-related changes in the human skin is unclear. In this study, we examined the relationship between autophagy and skin aging. Transmission electron microscopy and immunofluorescence microscopy analyses of skin tissue and cultured dermal fibroblasts derived from women of different ages revealed an increase in the number of nascent double-membrane autophagosomes with age. Western blot analysis showed that the amount of LC3-II, a form associated with autophagic vacuolar membranes, was significantly increased in aged dermal fibroblasts compared with that in young dermal fibroblasts. Aged dermal fibroblasts were minimally affected by inhibition of autophagic activity. Although lipofuscin autofluorescence was elevated in aged dermal fibroblasts, the expression of Beclin-1 and Atg5—genes essential for autophagosome formation—was similar between young and aged dermal fibroblasts, suggesting that the increase of autophagosomes in aged dermal fibroblasts was due to impaired autophagic flux rather than an increase in autophagosome formation. Treatment of young dermal fibroblasts with lysosomal protease inhibitors, which mimic the condition of aged dermal fibroblasts with reduced autophagic activity, altered the fibroblast content of type I procollagen, hyaluronan and elastin, and caused a breakdown of collagen fibrils. Collectively, these findings suggest that the autophagy pathway is impaired in aged dermal fibroblasts, which leads to deterioration of dermal integrity and skin fragility

  6. Alternative Fillers for the Production of Bituminous Mixtures: A Screening Investigation on Waste Powders

    Directory of Open Access Journals (Sweden)

    Cesare Sangiorgi

    2017-06-01

    Full Text Available There has been a significant increase in the demand for using recycled materials in construction because of the lack and limitation of available natural resources. A number of industrial and domestic waste products are being used in the replacement of traditional materials for road construction, and many studies have been carried out in recent years on the use of different recycled materials in substitution of conventional fillers in Asphalt Concretes (AC. The aim of this laboratory research is to analyze the physical characteristics of three different recycled fillers and compare them with those of a traditional limestone filler. The alternative fillers presented in this paper are: a waste bleaching clay that comes from two consecutive stages in the industrial process for decolouring vegetable oils and producing biogas (Ud filler, a dried mud waste from a tungsten mine (MW filler and a recycled glass powder (Gl filler. Results show significant differences between the fillers, and, in particular, Rigden Voids (RV seem to have the largest potential influence on the rheology of ACs.

  7. ZnO as a cheap and effective filler for high breakdown strength elastomers

    DEFF Research Database (Denmark)

    Yu, Liyun; Skov, Anne Ladegaard

    2017-01-01

    . In this article, we explore the use of a cheap and abundant metal oxide filler, namely ZnO, as a filler in silicone-based dielectric elastomers. The electro-mechanical properties of the elastomer composites are investigated, and their performance is evaluated by means of figures of merit. Various commercial...

  8. The Kinetics of Reversible Hyaluronic Acid Filler Injection Treated With Hyaluronidase.

    Science.gov (United States)

    Juhász, Margit L W; Levin, Melissa K; Marmur, Ellen S

    2017-06-01

    Hyaluronidase is an enzyme capable of dissolution of hyaluronic acid (HA). There is a lack of evidence-based research defining time- and concentration-dependent reversal of HA filler using hyaluronidase. To explore the efficacy of different concentrations of hyaluronidase in digesting commercially available HA-based reversible fillers-Belotero Balance (BEL), Juvederm Ultra XC (JUVXC), Juvederm Ultra Plus (JUVX+), Juvederm Voluma XC (JUVV), Restylane-L (RESL), Restylane Silk (RESS), and Perlane/Restylane Lyft (RESLYFT). This was a blinded randomized study involving 15 participants. Participants received HA filler injection into their back, followed by no secondary injection, or injection with normal saline, 20 or 40 units of hyaluronidase. Using a 5-point palpation scale, the degradation of HA filler was monitored over 14 days. In the authors' study, there is a significant decrease in HA filler degradation using 20 and 40 units of hyaluronidase compared with no secondary injection or normal saline. There is no significant difference in HA filler dissolution when comparing 20 to 40 units of hyaluronidase. Lower concentrations of hyaluronidase may be just as effective as higher concentrations to degrade HA filler in situations where the reversal of cutaneous augmentation with HA filler arises.

  9. Organic filler from golden apple snails shells to improve the silicone rubber insulator properties

    Science.gov (United States)

    Tepsila, Sujirat; Suksri, Amnart

    2018-02-01

    This paper investigates the effect of an addition of filler compound using golden apple snail shell as an organic filler to the silicone rubber insulator. The filler obtained from golden apple snail shell is found mostly contained calcium carbonate. The organic calcium carbonate (CaCO3) with particle size of 45, 75, 100 and 300 micron were prepared. Sample of silicone rubber that were filled with fillers were tested under ASTM D638-02a type standard for mechanical test. Also, electrical test such as I-V characteristics (ASTM D257-07) and dry arc test according to ASTM D495-14 have been performed. The results revealed that using larger particle size of organic filler obtained from the golden apple snail shell resulted to higher value of dielectric constant as well as higher dielectric strength. Also, the filler helps slow down the tracking activity at an insulator surface due to its crystals of calcium carbonate. However, when using excessive amount of filler, the sample will have a drawbacks in mechanical properties. By using agriculture waste as a filler compound, one can reduced the usage of commercial CaCO3 as an inorganic materials and to lower the investment cost to a final silicone rubber product.

  10. Effect of inorganic fillers in paper on the adhesion of pressure-sensitive adhesives

    Science.gov (United States)

    Weixu Chen; Xiaoyan Tang; John Considine; Kevin T. Turner

    2011-01-01

    Inorganic fillers are inexpensive materials used to increase the density, smoothness and other properties of paper that are important for printing. In the current study, the adhesion of pressure-sensitive adhesives (PSAs), a common type of adhesive used in labels and tapes, to papers containing varying amounts and types of fillers is investigated. Papers with three...

  11. Effects of fillers on the properties of liquid silicone rubbers (LSRs)

    DEFF Research Database (Denmark)

    Yu, Liyun; Vudayagiri, Sindhu; Zakaria, Shamsul Bin

    low viscosities, which is favorable for loading of inorganic fillers [5]. In this study, commercially available fillers, such as fumed silica (SiO2), titanium dioxide (TiO2), barium titanate (BaTiO3), copper calcium titanate (CaCu3Ti4O12, CCTO), multi-walled carbon nanotubes (MWCNTs) were added...

  12. Improved natural rubber composites reinforced with a complex filler network of biobased nanoparticles and ionomer

    Science.gov (United States)

    Biobased rubber composites are renewable and sustainable. Significant improvement in modulus of rubber composite reinforced with hydrophilic filler was achieved with the inclusion of ionomers. Soy particles aided with ionomer, carboxylated styrene-butadiene (CSB), formed a strong complex filler netw...

  13. Are functional fillers improving environmental behavior of plastics? A review on LCA studies.

    Science.gov (United States)

    Civancik-Uslu, Didem; Ferrer, Laura; Puig, Rita; Fullana-I-Palmer, Pere

    2018-06-01

    The use of functional fillers can be advantageous in terms of cost reduction and improved properties in plastics. There are many types of fillers used in industry, organic and inorganic, with a wide application area. As a response to the growing concerns about environmental damage that plastics cause, recently fillers have started to be considered as a way to reduce it by decreasing the need for petrochemical resources. Life cycle assessment (LCA) is identified as a proper tool to evaluate potential environmental impacts of products or systems. Therefore, in this study, the literature regarding LCA of plastics with functional fillers was reviewed in order to see if the use of fillers in plastics could be environmentally helpful. It was interesting to find out that environmental impacts of functional fillers in plastics had not been studied too often, especially in the case of inorganic fillers. Therefore, a gap in the literature was identified for the future works. Results of the study showed that, although there were not many and some differences exist among the LCA studies, the use of fillers in plastics industry may help to reduce environmental emissions. In addition, how LCA methodology was applied to these materials was also investigated. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Complications After Facial Injections With Permanent Fillers: Important Limitations and Considerations of MRI Evaluation

    NARCIS (Netherlands)

    Kadouch, Jonathan A.; Tutein Nolthenius, Charlotte J.; Kadouch, Daniel J.; van der Woude, Henk-Jan; Karim, Refaat B.; Hoekzema, Rick

    2014-01-01

    Background: Soft-tissue fillers have become more prevalent for facial augmentation in the last 2 decades, even though complications of permanent fillers can be challenging to treat. An investigative imaging tool could aid in assessing the nature and extent of these complications when clinical

  15. Rotation of magnetic particles inside the polymer matrix of magnetoactive elastomers with a hard magnetic filler

    Energy Technology Data Exchange (ETDEWEB)

    Stepanov, G.V., E-mail: gstepanov@mail.ru [State Scientific Research Institute of Chemistry and Technology of Organoelement Compounds, 105118 Moscow (Russian Federation); Borin, D.Yu. [TU Dresden, Magnetofluiddynamics, Measuring and Automation Technology, Dresden 01062 (Germany); Storozhenko, P.A. [State Scientific Research Institute of Chemistry and Technology of Organoelement Compounds, 105118 Moscow (Russian Federation)

    2017-06-01

    We propose the results of research on the magnetic properties of magnetoactive elastomers containing particles of a hard magnetic filler. According to our understanding, the mechanism of re-magnetizing of the composite is based on two competing processes, being the re-magnetizing of the magnetic filler and mechanical rotation of particles inside of the polymer matrix.

  16. Novel encapsulation technique for incorporation of high permittivity fillers into silicone elastomers

    DEFF Research Database (Denmark)

    Mazurek, Piotr Stanislaw; Hvilsted, Søren; Skov, Anne Ladegaard

    2014-01-01

    permittivity fillers, 2) Grafting of high permittivity molecules onto the polymer backbone in the elastomer, and 3) Encapsulation of high permittivity fillers. The approach investigated here is a new type of encapsulation which does not interfere with the mechanical properties to the same content...

  17. Merkel Cell Polyomavirus Infection of Animal Dermal Fibroblasts.

    Science.gov (United States)

    Liu, Wei; Krump, Nathan A; MacDonald, Margo; You, Jianxin

    2018-02-15

    Merkel cell polyomavirus (MCPyV) is the first polyomavirus to be associated with human cancer. Mechanistic studies attempting to fully elucidate MCPyV's oncogenic mechanisms have been hampered by the lack of animal models for MCPyV infection. In this study, we examined the ability of MCPyV-GFP pseudovirus (containing a green fluorescent protein [GFP] reporter construct), MCPyV recombinant virions, and several MCPyV chimeric viruses to infect dermal fibroblasts isolated from various model animals, including mouse ( Mus musculus ), rabbit ( Oryctolagus cuniculus ), rat ( Rattus norvegicus ), chimpanzee ( Pan troglodytes ), rhesus macaque ( Macaca mulatta ), patas monkey ( Erythrocebus patas ), common woolly monkey ( Lagothrix lagotricha ), red-chested mustached tamarin ( Saguinus labiatus ), and tree shrew ( Tupaia belangeri ). We found that MCPyV-GFP pseudovirus was able to enter the dermal fibroblasts of all species tested. Chimpanzee dermal fibroblasts were the only type that supported vigorous MCPyV gene expression and viral replication, and they did so to a level beyond that of human dermal fibroblasts. We further demonstrated that both human and chimpanzee dermal fibroblasts produce infectious MCPyV virions that can successfully infect new cells. In addition, rat dermal fibroblasts supported robust MCPyV large T antigen expression after infection with an MCPyV chimeric virus in which the entire enhancer region of the MCPyV early promoter has been replaced with the simian virus 40 (SV40) analog. Our results suggest that viral transcription and/or replication events represent the major hurdle for MCPyV cross-species transmission. The capacity of rat dermal fibroblasts to support MCPyV early gene expression suggests that the rat is a candidate model organism for studying viral oncogene function during Merkel cell carcinoma (MCC) oncogenic progression. IMPORTANCE MCPyV plays an important role in the development of a highly aggressive form of skin cancer, Merkel

  18. The mechanical properties of nanofilled resin-based composites: characterizing discrete filler particles and agglomerates using a micromanipulation technique.

    LENUS (Irish Health Repository)

    Curtis, Andrew R

    2009-02-01

    To assess the mechanical properties of discrete filler particles representative of several inorganic fillers in modern dental resin-based composites (RBCs) and to assess the validity of a novel micromanipulation technique.

  19. Recommendations for Filler Material Composition and Delivery Method for Bench-Scale Testing

    Energy Technology Data Exchange (ETDEWEB)

    Hardin, Ernest [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brady, Patrick Vane [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2018-03-01

    This report supplements Joint Workplan on Filler Investigations for DPCs (SNL 2017) providing new and some corrected information for use in planning Phase 1 laboratory testing of slurry cements as possible DPC fillers. The scope description is to "Describe a complete laboratory testing program for filler composition, delivery, emplacement in surrogate canisters, and post-test examination. To the extent possible specify filler material and equipment sources." This report includes results from an independent expert review (Dr. Arun Wagh, retired from Argonne National Laboratory and contracted by Sandia) that helped to narrow the range of cement types for consideration, and to provide further guidance on mix variations to optimize injectability, durability, and other aspects of filler performance.

  20. Silica-filled elastomers polymer chain and filler characterization by a SANS-SAXS approach

    CERN Document Server

    Botti, A; Richter, D; Urban, V; Ipns, A 6 4; Kohlbrecher, J; Straube, E

    2002-01-01

    A study of composites based upon commercially available silica fillers and networks of blends of protonated and deuterated anionically prepared polyisoprene is presented. The extraction of the single chain structure factor for SANS in the polymeric soft phase in isotropic and deformed state has been performed for the first time. The quasi three-component system could not be compositionally matched due to the internal structures of the activated fillers. For this, a parallel SAXS investigation provided the neccessary information on the filler structure which was lacking in the SANS analysis. Whereas mechanically clear reinforcement at low strains and filler-networking can be observed, the microscopic characterization of the chain deformation in the framework of the network tube model agrees with the estimates for hydrodynamic reinforcement of fractal fillers. (orig.)

  1. Use of hyaluronic acid fillers for the treatment of the aging face

    Directory of Open Access Journals (Sweden)

    Michael H Gold

    2007-10-01

    Full Text Available Michael H GoldGold Skin Care Center, Tennessee Clinical Research Center, Nashville, TN, USA; Department of Medicine, Vanderbilt University Medical School,Vanderbilt University Nursing School, Nashville, TN, USA; Huashan Hospital, Fudan University, Shanghai, ChinaAbstract: Hyaluronic acid fillers have become popular soft tissue filler augmentation agents over the past several years. They have helped revolutionize the filler market with a number of new products available for use for our patients. The purpose of this manuscript is to review the characteristics of the HA fillers and to review each of the current products currently available for use in the US.Keywords: hyaluronic acid, fillers, soft tissue augmentation, expression lines, aging face, collagen

  2. Silica-filled elastomers: polymer chain and filler characterization by a SANS-SAXS approach

    International Nuclear Information System (INIS)

    Botti, A.; Pyckhout-Hintzen, W.; Richter, D.; Urban, V.; Kohlbrecher, J.; Straube, E.

    2002-01-01

    A study of composites based upon commercially available silica fillers and networks of blends of protonated and deuterated anionically prepared polyisoprene is presented. The extraction of the single chain structure factor for SANS in the polymeric soft phase in isotropic and deformed state has been performed for the first time. The quasi three-component system could not be compositionally matched due to the internal structures of the activated fillers. For this, a parallel SAXS investigation provided the neccessary information on the filler structure which was lacking in the SANS analysis. Whereas mechanically clear reinforcement at low strains and filler-networking can be observed, the microscopic characterization of the chain deformation in the framework of the network tube model agrees with the estimates for hydrodynamic reinforcement of fractal fillers. (orig.)

  3. Improved TIG weld joint strength in aluminum alloy 2219-T87 by filler metal substitution

    Science.gov (United States)

    Poorman, R. M.; Lovoy, C. V.

    1972-01-01

    The results of an investigation on weld joint characteristics of aluminum alloy 2219-T87 are given. Five different alloys were utilized as filler material. The mechanical properties of the joints were determined at ambient and cryogenic temperatures for weldments in the as-welded condition and also, for weldments after elevated temperature exposures. Other evaluations included hardness surveys, stress corrosion susceptibility, and to a limited extent, the internal metallurgical weld structures. The overall results indicate that M-943 filler weldments are superior in strength to weldments containing either the standard 2319 filler or fillers 2014, 2020, and a dual wire feed consisting of three parts 2319 and one part 5652. In addition, no deficiencies were evident in M-934 filler weldments with regard to ductility, joint strength after elevated temperature exposure, weld hardness, metallographic structures, or stress corrosion susceptibility.

  4. Shape Effect of Crushed Sand Filler on Rheology: A Preliminary Experimental and Numerical Study

    DEFF Research Database (Denmark)

    Spangenberg, Jon; Cepuritis, Rolands; Hovad, Emil

    2016-01-01

    Two types of filler from crushed sand were mixed with cement paste with constant superplasticizer dosage per mass of cement to investigate how their shape affects the rheology. The fillers were mylonitic quartz diorite and limestone produced using Vertical Shaft Impact (VSI) crusher and air...... was quantified with the slump flow test (i.e. mini cone). The shape effect was isolated in the experiments by the use of non overlapping bimodal particle distributions of cement particles with a number average diameter of approximate to 0.01 mm and filler particles with a number average diameter of approximate...... to 0.1 mm. The two filler types were tested with a range of chi-values (volume of cement divided by total volume of solids). The flowability of the matrix increased with decreasing aspect ratios of the filler. However, the chi-value at which the maximum volume fraction threshold was obtained varied...

  5. The effect of mixing order of fillers on the physical properties of EPDM

    International Nuclear Information System (INIS)

    Gul, J.; Saleemi, A.R.

    2007-01-01

    In this research the effect of mixing order of fillers on the physical properties of EPDM (Ethylene Propylene Diene Monomer) vulcanizates was studied. EPDM was compounded with other ingredients i.e. fillers, process aid, curing package etc in order to get the needed physical properties for thermal insulation. All the factors, which could affect the physical properties of EPDM vulcanizates such as quality and quantity of raw materials, storage conditions of ingredients and vulcanizates, compounding and testing facilities, mixing time, process parameters etc were kept constant except mixing order of addition of filler to EPDM. Different batches of EPDM vulcanizates with different mixing order/sequence of filler to EPDM were prepared and tested for physical properties like density, hardness, tensile strength and elongation. It was concluded that mixing order of filler to EPDM affects tensile strength, elongation and hardness and does not affect density of the EPDM vulcanizate. (author)

  6. Influence of the filler material on the pitting corrosion in welded duplex stainless

    International Nuclear Information System (INIS)

    Munez, C. J.; Utrilla, M. V.; Urena, A.; Otero, E.

    2007-01-01

    In this work, it has been studied the pitting corrosion resistance of welding duplex stainless steel 2205. Unions were made by GMAW process with different fillers: duplex ER 2209 and two austenitic (ER 316LSi and ER 308LSi). the microstructure obtained with the duplex ER 2209 filler is similar to the duplex 2205 base material, but the unions produced with the austenitic fillers cause a decrease of the phases relationα/γ. To evaluate the influence of the filler on the weld, the pitting corrosion resistance was determined by electrochemical critical pitting temperature test (TCP) and the mechanical properties by the hardness. The phases imbalance produced for the dissimilar fillers bring out a variation of the pitting corrosion resistance and the mechanical properties. (Author)

  7. Efek Pemberian Suntikan Subkutan Vitamin C Terhadap Luka Insisi Dermal

    Directory of Open Access Journals (Sweden)

    Surya Darma

    2014-09-01

    Full Text Available Abstrak Vitamin C berfungsi sebagai kofaktor enzyme prolil dan lysil hydroxilase. Enzym tersebut berfungsi dalam proses hidroksilasi yang membentuk ikatan hidroksiprolin dan hidroksilisin pada fibroblast dalam membentuk kolagen. Selain itu Vitaimin C juga berfungsi meregulasi dan menstabilkan trankripsi gen mRNA prokolagen pada proses pembentukan kolagen di dermis. Berdasarkan hal tersebut diatas, peneliti tertarik untuk membuktikan apakah pemberian vitamin C subkutan disekitar luka insisi dermal berefek pada pembentukan kolagen yang lebih padat dalam proses penyembuhan luka. Metode: Penelitian eksperimental ini menggunakan tikus Wistar sebanyak 32 ekor, yang dibagi menjadi 2 kelompok yaitu 16 ekor sebagai kontrol dan 16 ekor lagi sebagai perlakuan. Pada kedua kelompok dilakukan insisi di punggung sepanjang 2 cm. Kelompok perlakuan diberi suntikan vitamin C subkutan disekitar luka insisi dermal sebanyak 9 mg (0,09ml, sedangkan kelompokkontrol tidak diberikan.Pada hari kelima dilakukan pengambilan jaringan luka pada kedua sampel untuk pemeriksaan kepadatan kolagen secara mikroskopik. Hasil:Kepadatan kolagen pada hari kelimamenunjukkan perbedaan yang bermakna dari efek penyuntikan vitamin C subkutan terhadap kepadatan kolagen (χ2 = 5,833; P<0,05. Kesimpulan: Penyuntikan vitamin C subkutan disekitar luka insisi dermal efektif dalam meeningkatan kepadatan kolagen. Kata kunci: suntikan vitamin C subkutan, kepadatan kolagen.Abstract Vitamin C functions as enzyme co-factor for prolyl and hidroxylase lysil. The enzyme functions in hydroxylase process that builds hydroxyproline and hydroxylysine bondsin fibroblast in the synthesis of collagen. Besides that, vitamin C also functions in regulating and stabilizing procollagen mRNA gen transcription in dermal collagen synthesis. Based on the facts above, researchers are interested to prove whether subcutaneous injection of vitamin C around dermal insisional wound would result in more compact collagen

  8. Efek Pemberian Suntikan Subkutan Vitamin C Terhadap Luka Insisi Dermal

    Directory of Open Access Journals (Sweden)

    Surya Darma

    2013-09-01

    Full Text Available Abstrak Vitamin C berfungsi sebagai kofaktor enzyme prolil dan lysil hydroxilase. Enzym tersebut berfungsi dalam proses hidroksilasi yang membentuk ikatan hidroksiprolin dan hidroksilisin pada fibroblast dalam membentuk kolagen. Selain itu Vitaimin C juga berfungsi meregulasi dan menstabilkan trankripsi gen mRNA prokolagen pada proses pembentukan kolagen di dermis. Berdasarkan hal tersebut diatas, peneliti tertarik untuk membuktikan apakah pemberian vitamin C subkutan disekitar luka insisi dermal berefek pada pembentukan kolagen yang lebih padat dalam proses penyembuhan luka. Metode: Penelitian eksperimental ini menggunakan tikus Wistar sebanyak 32 ekor, yang dibagi menjadi 2 kelompok yaitu 16 ekor sebagai kontrol dan 16 ekor lagi sebagai perlakuan. Pada kedua kelompok dilakukan insisi di punggung sepanjang 2 cm. Kelompok perlakuan diberi suntikan vitamin C subkutan disekitar luka insisi dermal sebanyak 9 mg (0,09ml, sedangkan kelompokkontrol tidak diberikan.Pada hari kelima dilakukan pengambilan jaringan luka pada kedua sampel untuk pemeriksaan kepadatan kolagen secara mikroskopik. Hasil:Kepadatan kolagen pada hari kelimamenunjukkan perbedaan yang bermakna dari efek penyuntikan vitamin C subkutan terhadap kepadatan kolagen (χ2 = 5,833; P<0,05. Kesimpulan: Penyuntikan vitamin C subkutan disekitar luka insisi dermal efektif dalam meeningkatan kepadatan kolagen. Kata kunci: suntikan vitamin C subkutan, kepadatan kolagen. Abstract Vitamin C functions as enzyme co-factor for prolyl and hidroxylase lysil. The enzyme functions in hydroxylase process that builds hydroxyproline and hydroxylysine bondsin fibroblast in the synthesis of collagen. Besides that, vitamin C also functions in regulating and stabilizing procollagen mRNA gen transcription in dermal collagen synthesis. Based on the facts above, researchers are interested to prove whether subcutaneous injection of vitamin C around dermal insisional wound would result in more compact collagen

  9. Inhalational and dermal exposures during spray application of biocides.

    Science.gov (United States)

    Berger-Preiss, Edith; Boehncke, Andrea; Könnecker, Gustav; Mangelsdorf, Inge; Holthenrich, Dagmar; Koch, Wolfgang

    2005-01-01

    Data on inhalational and potential dermal exposures during spray application of liquid biocidal products were generated. On the one hand, model experiments with different spraying devices using fluorescent tracers were carried out to investigate the influence of parameters relevant to the exposure (e.g. spraying equipment, nozzle size, direction of application). On the other hand, measurements were performed at selected workplaces (during disinfection operations in food and feed areas; pest control operations for private, public and veterinary hygiene; wood protection and antifouling applications) after application of biocidal products such as Empire 20, Responsar SC, Omexan-forte, Actellic, Perma-forte; Fendona SC, Pyrethrum mist; CBM 8, Aldekol Des 03, TAD CID, Basileum, Basilit. The measurements taken in the model rooms demonstrated dependence of the inhalation exposure on the type of spraying device used, in the following order: "spraying with low pressure" < "airless spraying" < "fogging" indicating that the particle diameter of the released spray droplets is the most important parameter. In addition inhalation exposure was lowest when the spraying direction was downward. Also for the potential dermal exposure, the spraying direction was of particular importance: overhead spraying caused the highest contamination of body surfaces. The data of inhalational and potential dermal exposures gained through workplace measurements showed considerable variation. During spraying procedures with low-pressure equipments, dose rates of active substances inhaled by the operators ranged from 7 to 230 microg active substance (a.s.)/h. An increase in inhaled dose rates (6-33 mg a.s./h) was observed after use of high application volumes/time unit during wood protection applications indoors. Spraying in the veterinary sector using medium-pressure sprayers led to inhaled dose rates between 2 and 24mga.s./h. The highest inhaled dose rates were measured during fogging (114 mg a

  10. Wetting and spreading behavior of molten brazing filler metallic alloys on metallic substrate

    Science.gov (United States)

    Kogi, Satoshi; Kajiura, Tetsurou; Hanada, Yukiakira; Miyazawa, Yasuyuki

    2014-08-01

    Wetting and spreading of molten brazing filler material are important factors that influence the brazing ability of a joint to be brazed. Several investigations into the wetting ability of a brazing filler alloy and its surface tension in molten state, in addition to effects of brazing time and temperature on the contact angle, have been carried out. In general, dissimilar-metals brazing technology and high-performance brazed joint are necessities for the manufacturing field in the near future. Therefore, to address this requirement, more such studies on wetting and spreading of filler material are required for a deeper understanding. Generally, surface roughness and surface conditions affect spreading of molten brazing filler material during brazing. Wetting by and interfacial reactions of the molten brazing filler material with the metallic substrate, especially, affect strongly the spreading of the filler material. In this study, the effects of surface roughness and surface conditions on the spreading of molten brazing filler metallic alloys were investigated. Ag-(40-x)Cu-xIn and Ag- (40-x)Cu-xSn (x=5, 10, 15, 20, 25) alloys were used as brazing filler materials. A mild-steel square plate (S45C (JIS); side: 30 mm; thickness: 3mm) was employed as the substrate. A few surfaces with varying roughness were prepared using emery paper. Brazing filler material and metallic base plate were first washed with acetone, and then a flux was applied to them. The filler, 50 mg, was placed on the center of the metallic base with the flux. A spreading test was performed under Ar gas using an electrically heated furnace, after which, the original spreading area, defined as the sessile drop area, and the apparent spreading area, produced by the capillary grooves, were both evaluated. It was observed that the spreading area decreased with increasing In and Sn content.

  11. Study of Tetrapodal ZnO-PDMS Composites: A Comparison of Fillers Shapes in Stiffness and Hydrophobicity Improvements

    OpenAIRE

    Jin, Xin; Deng, Mao; Kaps, Sören; Zhu, Xinwei; Hölken, Iris; Mess, Kristin; Adelung, Rainer; Mishra, Yogendra Kumar

    2014-01-01

    ZnO particles of different size and structures were used as fillers to modify the silicone rubber, in order to reveal the effect of the filler shape in the polymer composites. Tetrapodal shaped microparticles, short microfibers/whiskers, and nanosized spherical particles from ZnO have been used as fillers to fabricate the different ZnO-Silicone composites. The detailed microstructures of the fillers as well as synthesized composites using scanning electron microscopy have been presented here....

  12. Effects of SiO 2 and TiO 2 fillers on thermal and dielectric properties ...

    Indian Academy of Sciences (India)

    The microstructures and distribution of fillers in the glass matrix have been analyzed by SEM images. It is observed that the fillers have partially dissolved in the glass at the firing temperature leaving some unreacted filler as residue which results in ceramic–glass microcomposites. In consideration of the desired properties of ...

  13. Numerical Investigation of T-joints with 3D Four Directional Braided Composite Fillers Under Tensile Loading

    Science.gov (United States)

    Li, Xiao-kang; Liu, Zhen-guo; Hu, Long; Wang, Yi-bo; Lei, Bing; Huang, Xiang

    2017-02-01

    Numerical studied on T-joints with three-dimensional four directional (3D4D) braided composite fillers was presented in this article. Compared with conventional unidirectional prepreg fillers, the 3D braided composite fillers have excellent ability to prevent crack from penetrating trigone fillers, which constantly occurred in the conventional fillers. Meanwhile, the 3D braided composite fillers had higher fiber volume fraction and eliminated the fiber folding problem in unidirectional prepreg fillers. The braiding technology and mechanical performance of 3D4D braided fillers were studied. The numerical model of carbon fiber T-joints with 3D4D braided composite fillers was built by finite element analysis software. The damage formation, extension and failing process of T-joints with 3D4D braided fillers under tensile load were investigated. Further investigation was extended to the effect of 3D4D braided fillers with different braiding angles on mechanical behavior of the T-joints. The study results revealed that the filling area was the weakest part of the T-joints where the damage first appeared and the crack then rapidly spread to the glue film around the filling area and the interface between over-laminate and soleplate. The 3D4D braided fillers were undamaged and the braiding angle change induced a little effect on the bearing capacity of T-joints.

  14. Behaviour of cellular structures with fluid fillers under impact loading

    Directory of Open Access Journals (Sweden)

    Matej Vesenjak

    2007-03-01

    Full Text Available The paper investigates the behaviour of closed- and open-cell cellular structures under uniaxial impact loading by means of computational simulations using the explicit nonlinear finite element code LS-DYNA. Simulations also consider the influence of pore fillers and the base material strain rate sensitivity. The behaviour of closed-cell cellular structure has been evaluated with use of the representative volume element, where the influence of residual gas inside the closed pores has been studied. Open- cell cellular structure was modelled as a whole to properly account for considered fluid flow through the cells, which significantly influences macroscopic behaviour of the cellular structure. The fluid has been modelled by applying a meshless Smoothed Particle Hydrodynamics (SPH method. Parametric computational simulations provide grounds for optimization of cellular structures to satisfy different requirements, which makes them very attractive for use in general engineering applications.

  15. ANALYSIS OF MPC ACCESS REQUIREMENTS FOR ADDITION OF FILLER MATERIALS

    International Nuclear Information System (INIS)

    W. Wallin

    1996-01-01

    This analysis is prepared by the Mined Geologic Disposal System (MGDS) Waste Package Development Department (WPDD) in response to a request received via a QAP-3-12 Design Input Data Request (Ref. 5.1) from WAST Design (formerly MRSMPC Design). The request is to provide: Specific MPC access requirements for the addition of filler materials at the MGDS (i.e., location and size of access required). The objective of this analysis is to provide a response to the foregoing request. The purpose of this analysis is to provide a documented record of the basis for the response. The response is stated in Section 8 herein. The response is based upon requirements from an MGDS perspective

  16. Amorphous filler metal foils for brazing zirconium grid plates

    International Nuclear Information System (INIS)

    Plyushchev, A.N.; Kalin, B.A.; Fedotov, V.T.; Sevryukov, O.N.; Mamedova, T.T.; Shestakov, E.F.; Timoshin, S.N.

    2001-01-01

    A new amorphous ribbon filler metal of Zr-5.5 Fe-2.5 Be-1.0 Nb-8.0 Cu-2.0 Sn-0.4 Cr (mass %) with the temperature of melting onset of 745-750 deg C is designed to braze spacer grids of zirconium base alloys. The brazing conditions (780-790 deg C, 40-45 s) are determined which provide minimal standing at temperatures above 700 deg C (∼ 1.5 min) for spacer grids. Mechanical tests show that tensile strength of brazed joints is 55-59 kgf what is twice that of analogous welded joints. In addition, the brazed joints exhibit high corrosion resistance when testing in a distilled steam-water mixture at a temperature of 350 deg C and 16.5 MPa pressure for 10000 h [ru

  17. Mechanical properties of experimental composites with different calcium phosphates fillers.

    Science.gov (United States)

    Okulus, Zuzanna; Voelkel, Adam

    2017-09-01

    Calcium phosphates (CaPs)-containing composites have already shown good properties from the point of view of dental restorative materials. The purpose of this study was to examine the crucial mechanical properties of twelve hydroxyapatite- or tricalcium phosphate-filled composites. The raw and surface-treated forms of both CaP fillers were applied. As a reference materials two experimental glass-containing composites and one commercial dental restorative composite were applied. Nano-hardness, elastic modulus, compressive, flexural and diametral tensile strength of all studied materials were determined. Application of statistical methods (one-way analysis of variance and cluster agglomerative analysis) allowed for assessing the similarities between examined materials according to the values of studied parameters. The obtained results show that in almost all cases the mechanical properties of experimental CaPs-composites are comparable or even better than mechanical properties of examined reference materials. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Sugarcane bagasse ash: new filler to natural rubber composite

    Directory of Open Access Journals (Sweden)

    Renivaldo José dos Santos

    2014-12-01

    Full Text Available Waste recycling has been the subject of numerous scientific researches regarding the environmental care. This paper reports the redirecting of sugarcane bagasse ash (SBA as new filler to natural rubber (NR/SBA. The NR/SBA composites were prepared using an opened cylinder mixer to incorporate the vulcanization agents and different proportions of residue (SBA. The ash contains about 70-90% of inorganic compounds, with silica (SiO2 being the main compound. The SBA incorporation improved the mechanical properties of the vulcanized rubber. Based on these results, a new use is proposed for the agro-industry organic waste to be implemented in the rubber vulcanization process, aimed at improving the rubber physical properties as well as decreasing the prices of natural rubber composites.

  19. Epoxy composites based on inexpensive tire waste filler

    International Nuclear Information System (INIS)

    Ahmetli, Gulnare; Gungor, Ahmet; Kocaman, Suheyla

    2014-01-01

    Tire waste (TW) was recycled as raw material for the preparation of DGEBA-type epoxy composite materials. The effects of filler amount and epoxy type on the mechanical properties of the composites were investigated. Tensile strength and Young’s modulus of the composites with NPEL were generally higher than composites with NPEF. The appropriate mass level for TW in both type composites was found to be 20 wt%. The equilibrium water sorption of NPEL/TW and NPEF/TW composites for 14-day immersion was determined as 0.10 % and 0.21 %, respectively. Scanning electron microscopy (SEM) and X-ray diffraction (XRD) were used for characterization of the composites

  20. Wh-filler-gap dependency formation guides reflexive antecedent search

    Directory of Open Access Journals (Sweden)

    Michael eFrazier

    2015-10-01

    Full Text Available Prior studies on online sentence processing have shown that the parser can resolve non-local dependencies rapidly and accurately. This study investigates the interaction between the processing of two such non-local dependencies: wh-filler-gap dependencies (WhFGD and reflexive-antecedent dependencies. We show that reflexive-antecedent dependency resolution is sensitive to the presence of a WhFGD, and argue that the filler-gap dependency established by WhFGD resolution is selected online as the antecedent of a reflexive dependency. We investigate the processing of constructions like (1, where two NPs might be possible antecedents for the reflexive, namely which cowgirl and Mary. Even though Mary is linearly closer to the reflexive, the only grammatically licit antecedent for the reflexive is the more distant wh-NP, which cowgirl. 1. Which cowgirl did Mary expect to have injured herself due to negligence?Four eye-tracking text-reading experiments were conducted on examples like (1, differing in whether the embedded clause was non-finite (1 and 3 or finite (2 and 4, and in whether the tail of the wh-dependency intervened between the reflexive and its closest overt antecedent (1 and 2 or the wh-dependency was associated with a position earlier in the sentence (3 and 4.The results of Experiments 1 and 2 indicate the parser accesses the result of WhFGD formation during reflexive antecedent search. The resolution of a wh-dependency alters the representation that reflexive antecedent search operates over, allowing the grammatical but linearly distant antecedent to be accessed rapidly. In the absence of a long-distance WhFGD (Exp. 3 and 4, wh-NPs were not found to impact reading times of the reflexive, indicating that the parser's ability to select distant wh-NPs as reflexive antecedents crucially involves syntactic structure.

  1. Cleft Palate Fistula Closure Utilizing Acellular Dermal Matrix

    Directory of Open Access Journals (Sweden)

    Omri Emodi, DMD

    2018-03-01

    Full Text Available Summary:. Fistulas represent failure of cleft palate repair. Secondary and tertiary fistula repair is challenging, with high recurrence rates. In the present retrospective study, we review the efficacy of using acellular dermal matrix as an interposition layer for cleft palate fistula closure in 20 consecutive patients between 2013 and 2016. Complete fistula closure was obtained in 16 patients; 1 patient had asymptomatic recurrent fistula; 2 patients had partial closure with reduction of fistula size and minimal nasal regurgitation; 1 patient developed a recurrent fistula without changes in symptoms (success rate of 85%. We conclude that utilizing acellular dermal matrix for cleft palate fistula repair is safe and simple with a high success rate.

  2. Bio-artificial pleura using an autologous dermal fibroblast sheet

    Science.gov (United States)

    Kanzaki, Masato; Takagi, Ryo; Washio, Kaoru; Kokubo, Mami; Yamato, Masayuki

    2017-10-01

    Air leaks (ALs) are observed after pulmonary resections, and without proper treatment, can produce severe complications. AL prevention is a critical objective for managing patients after pulmonary resection. This study applied autologous dermal fibroblast sheets (DFS) to close ALs. For sealing ALs in a 44-year-old male human patient with multiple bullae, a 5 × 15-mm section of skin was surgically excised. From this skin specimen, primary dermal fibroblasts were isolated and cultured for 4 weeks to produce DFSs that were harvested after a 10-day culture. ALs were completely sealed using surgical placement of these autologous DFSs. DFS were found to be a durable long-term AL sealant, exhibiting requisite flexibility, elasticity, durability, biocompatibility, and usability, resulting reliable AL closure. DFS should prove to be an extremely useful tissue-engineered pleura substitute.

  3. Further delineation of the odonto-onycho-dermal dysplasia syndrome.

    Science.gov (United States)

    Mégarbané, Hala; Haddad, May; Delague, Valérie; Renoux, Julien; Boehm, Nelly; Mégarbané, André

    2004-08-30

    We report on three boys, two brothers and their maternal cousin, presenting with dry hair, pilar keratosis, severe hypodontia, smooth tongue, onychodysplasia, and keratoderma and hyperhidrosis of palms and soles. Histology of the skin showed orthokeratotic, hyperkeratosis, hypergranulosis, and mild acanthosis in the epidermis. Scanning electron microscopic examination of the hair showed longitudinal depressions in some hair. These features are close to a rare entity: the odonto-onycho-dermal dysplasia but with some differing features. Copyright 2004 Wiley-Liss, Inc.

  4. Phacomatosis pigmento-pigmentaria: aberrant dermal melanocytosis and nevus spilus.

    Science.gov (United States)

    Wolf, Ronni; Ruocco, Eleonora; Baroni, Adone

    2011-08-15

    We present a dermal melanocytosis with superimposed nevus spilus on the arm of a 5-year-old boy. We recently introduced a new type of phacomatosis, which we termed "phacomatosis pigmentopigmentalis," that is analogous to phacomatosis pigmentokeratotica or pigmentovascularis, for describing the association of two pigmented nevi. The present case is an example of this type of phacomatosis, which now we prefer to define phacomatosis pigmento-pigmentaria according to the correct Latin terminology.

  5. Potential health effects associated with dermal exposure to occupational chemicals.

    Science.gov (United States)

    Anderson, Stacey E; Meade, B Jean

    2014-01-01

    There are a large number of workers in the United States, spanning a variety of occupational industries and sectors, who are potentially exposed to chemicals that can be absorbed through the skin. Occupational skin exposures can result in numerous diseases that can adversely affect an individual's health and capacity to perform at work. In general, there are three types of chemical-skin interactions of concern: direct skin effects, immune-mediated skin effects, and systemic effects. While hundreds of chemicals (metals, epoxy and acrylic resins, rubber additives, and chemical intermediates) present in virtually every industry have been identified to cause direct and immune-mediated effects such as contact dermatitis or urticaria, less is known about the number and types of chemicals contributing to systemic effects. In an attempt to raise awareness, skin notation assignments communicate the potential for dermal absorption; however, there is a need for standardization among agencies to communicate an accurate description of occupational hazards. Studies have suggested that exposure to complex mixtures, excessive hand washing, use of hand sanitizers, high frequency of wet work, and environmental or other factors may enhance penetration and stimulate other biological responses altering the outcomes of dermal chemical exposure. Understanding the hazards of dermal exposure is essential for the proper implementation of protective measures to ensure worker safety and health.

  6. Dynamic interactions between dermal macrophages and Staphylococcus aureus.

    Science.gov (United States)

    Feuerstein, Reinhild; Kolter, Julia; Henneke, Philipp

    2017-01-01

    The dermis, a major reservoir of immune cells in immediate vicinity to the colonizing skin microflora, serves as an important site of host-pathogen interactions. Macrophages (Mϕ) are the most frequent resident immune cell type in the dermis. They protect the host from invasive infections by highly adapted bacteria, such as staphylococci via pattern recognition of bacterial effectors, phagocytosis, and recruitment of other myeloid cells from the blood. Already under homeostatic conditions, the dermal Mϕ population receives a dynamic input of monocytes invading from the bloodstream. This quantitative renewal is promoted further at the beginning of life, when prenatally seeded cells are rapidly replaced and in healing phases after injuries or infections. Here, we discuss the potential implications of the dynamic dermal Mϕ biology on the establishment and maintenance of immunity against Staphylococcus aureus, which can either be a harmless colonizer or an invasive pathogen. The understanding of the heterogeneity of the "mature" dermal Mϕ compartment driven both by the influx of differentiating monocytes and by a bone marrow-independent Mϕ persistence and expansion may help to explain failing immunity and immunopathology originating from the skin, the important interface between host and environment. © Society for Leukocyte Biology.

  7. Dermal insecticide residues from birds inhabiting an orchard

    Science.gov (United States)

    Vyas, N.B.; Spann, J.W.; Hulse, C.S.; Gentry, S.; Borges, S.L.

    2007-01-01

    The US Environmental Protection Agency conducts risk assessments of insecticide applications to wild birds using a model that is limited to the dietary route of exposure. However, free-flying birds are also exposed to insecticides via the inhalation and dermal routes. We measured azinphos-methyl residues on the skin plus feathers and the feet of brown-headed cowbirds (Molothrus ater) in order to quantify dermal exposure to songbirds that entered and inhabited an apple (Malus x domestica) orchard following an insecticide application. Exposure to azinphos-methyl was measured by sampling birds from an aviary that was built around an apple tree. Birds sampled at 36 h and 7-day post-application were placed in the aviary within 1 h after the application whereas birds exposed for 3 days were released into the aviary 4-day post-application. Residues on vegetation and soil were also measured. Azinphos-methyl residues were detected from the skin plus feathers and the feet from all exposure periods. Our results underscore the importance of incorporating dermal exposure into avian pesticide risk assessments.

  8. Dermal morphological changes following salicylic acid peeling and microdermabrasion.

    Science.gov (United States)

    Abdel-Motaleb, Amira A; Abu-Dief, Eman E; Hussein, Mahmoud Ra

    2017-12-01

    Microdermabrasion and chemical peeling are popular, inexpensive, and safe methods for treatment of some skin disorders and to rejuvenate skin. To study the alterations of the dermal connective tissue following salicylic acid peeling and microdermabrasion. Twenty patients were participated in our study. All participants underwent facial salicylic acid 30% peel or microdermabrasion (10 cases in each group) weekly for 6 weeks. Punch biopsies were obtained from the clinically normal skin of the right postauricular region 1 week before treatment (control group). Other punch skin biopsies were obtained 1 week after the end of the treatments from the left postauricular area. This region was treated in a similar way to the adjacent lesional skin (treated group). We used routine histological techniques (H&E stain), special stains (Masson trichrome and orcein stains), and image analyzer to study the alterations of the dermal connective tissues. Our study demonstrates variations in the morphological changes between the control and the treated groups, and between chemical peels and microdermabrasion. Both salicylic acid 30% and microdermabrasion were associated with thickened epidermal layer, shallow dermal papillae, dense collagen, and elastic fibers. There was a significant increase among those treated sites vs control regarding epidermal thickness and collagen thickness. Also, there was a highly statistically significant increase among those treated with salicylic acid vs microdermabrasion regarding the epidermal, collagen, and elastin thickness. Both methods stimulate the repair process. The mechanisms underlying these variations are open for further investigations. © 2017 Wiley Periodicals, Inc.

  9. Influence of inert fillers on shrinkage cracking of meta-kaolin geo-polymers

    International Nuclear Information System (INIS)

    Kuenzel, C.; Boccaccini, A.R.

    2012-01-01

    Geo-polymers contain a network of tetrahedral coordinated aluminate and silicate, and are potential materials to immobilize/encapsulate nuclear wastes. They can exhibit shrinkage cracking when water is removed by drying, and in order to use geo-polymers for waste encapsulation this effect needs to be investigated and controlled. In this study, six different fillers were mixed with meta-kaolin and sodium silicate solution at high pH to form geo-polymers, and the influence of filler addition on mechanical properties has been determined. The fillers used were Fe 2 O 3 , Al 2 O 3 , CaCO 3 , sand, glass and rubber and these do not react during geo-polymerisation reactions. Geo-polymers were prepared containing 30 weight percent of filler. The mechanical properties of the geo-polymers were influenced by the type of filler, with low density fillers increasing mortar viscosity. Geo-polymer samples containing fine filler particles exhibited shrinkage cracking on drying. This was not observed when coarser particles were added and these samples also had significantly improved mechanical properties. (authors)

  10. Fluoride release, recharge and flexural properties of polymethylmethacrylate containing fluoridated glass fillers.

    Science.gov (United States)

    Al-Bakri, I A; Swain, M V; Naoum, S J; Al-Omari, W M; Martin, E; Ellakwa, A

    2014-06-01

    The purpose of this study was to investigate the effect of fluoridated glass fillers on fluoride release, recharge and the flexural properties of modified polymethylmethacrylate (PMMA). Specimens of PMMA denture base material with various loading of fluoridated glass fillers (0%, 1%, 2.5%, 5% and 10% by weight) were prepared. Flexural properties were evaluated on rectangular specimens (n = 10) aged in deionized water after 24 hours, 1 and 3 months. Disc specimens (n = 10) were aged for 43 days in deionized water and lactic acid (pH 4.0) and fluoride release was measured at numerous intervals. After ageing, specimens were recharged and fluoride re-release was recorded at 1, 3 and 7 days after recharge. Samples containing 2.5%, 5% and 10% glass fillers showed significantly (p glass fillers specimens. All experimental specimens exhibited fluoride release in both media. The flexural strength of specimens decreased in proportion to the percentage filler inclusion with the modulus of elasticity values remaining within ISO Standard 1567. The modified PMMA with fluoridated glass fillers has the ability to release and re-release fluoride ion. Flexural strength decreased as glass filler uploading increased. © 2014 Australian Dental Association.

  11. Effect of Coconut Fillers on Hybrid Coconut Kevlar Fiber Reinforced Epoxy Composites

    Directory of Open Access Journals (Sweden)

    S. P. Jani

    2015-12-01

    Full Text Available This project focuses on the conversion of naturally available coconut fibers and shells into a useful composite. In addition to it, some mechanical properties of the resultant composite is determined and also the effect of coconut shell fillers on the composite is also investigated. The few portion of the composite is incorporated with synthetic Kevlar fiber, thus the coconut fiber is hybridized to enhance the mechanical properties of coconut. In this work two types of composite is fabricate, kevelar coconut fibre (kc composite and kevelarcoco nut fibre coconut shell filler (kccsf composite. Coconut fibers have low weight and considerable properties among the natural fibers, while coconut fillers have a good ductile and impact property. The natural fibers and fillers are treated with Na-OH to make it free of organic impurities. Epoxy resin is used as the polymer matrix. Two composite are produced one with fillers and the other without the fillers using compression molding method. Mechanical properties like tensile strength, flexural strength and water absorption tests are done with ASTM standard. It is observed that that the addition of filler materials improves the adhesiveness of the fibers leading to the increase in the above mentioned properties. The density of the composite is also low hence the strength to weight ratio is very high. The water absorption test also showed that the resultant composite had a small adhesion to water and absorption of water.

  12. Influence of silane content and filler distribution on chemical-mechanical properties of resin composites

    Directory of Open Access Journals (Sweden)

    Tathy Aparecida XAVIER

    2015-01-01

    Full Text Available This study investigated the influence of silane concentration and filler size distribution on the chemical-mechanical properties of experimental composites. Experimental composites with silane contents of 0%, 1% and 3% (in relation to filler mass and composites with mixtures of barium glass particles (median size = 0.4, 1 and 2 μm and nanometric silica were prepared for silane and filler analyses, respectively. The degree of conversion (DC was analyzed by FTIR. Biaxial flexural strength (BFS was tested after 24-h or 90-d storage in water, and fracture toughness, after 24 h. The data were subjected to ANOVA and Tukey’s test (p = 0.05. The DC was not significantly affected by the silane content or filler distribution. The 0% silane group had the lowest immediate BFS, and the 90-d storage time reduced the strength of the 0% and 3% groups. BFS was not affected by filler distribution, and aging decreased the BFS of all the groups. Silanization increased the fracture toughness of both the 1% and 3% groups, similarly. Significantly higher fracture toughness was observed for mixtures with 2 μm glass particles. Based on the results, 3% silane content boosted the initial strength, but was more prone to degradation after water storage. Variations in the filler distribution did not affect BFS, but fracture toughness was significantly improved by increasing the filler size.

  13. Effects of age condition on the distribution and integrity of inorganic fillers in dental resin composites.

    Science.gov (United States)

    D'Alpino, Paulo Henrique Perlatti; Svizero, Nádia da Rocha; Bim Júnior, Odair; Valduga, Claudete Justina; Graeff, Carlos Frederico de Oliveira; Sauro, Salvatore

    2016-06-01

    The aim of this study is to evaluate the distribution of the filler size along with the zeta potential, and the integrity of silane-bonded filler surface in different types of restorative dental composites as a function of the material age condition. Filtek P60 (hybrid composite), Filtek Z250 (small-particle filled composite), Filtek Z350XT (nanofilled composite), and Filtek Silorane (silorane composite) (3M ESPE) were tested at different stage condition (i.e., fresh/new, aged, and expired). Composites were submitted to an accelerated aging protocol (Arrhenius model). Specimens were obtained by first diluting each composite specimen in ethanol and then dispersed in potassium chloride solution (0.001 mol%). Composite fillers were characterized for their zeta potential, mean particle size, size distribution, via poly-dispersion dynamic light scattering. The integrity of the silane-bonded surface of the fillers was characterized by FTIR. The material age influenced significantly the outcomes; Zeta potential, filler characteristics, and silane integrity varied both after aging and expiration. Silorane presented the broadest filler distribution and lowest zeta potential. Nanofilled and silorane composites exhibited decreased peak intensities in the FTIR analysis, indicating a deficiency of the silane integrity after aging or expiry time. Regardless to the material condition, the hybrid and the small-particle-filled composites were more stable overtime as no significant alteration in filler size distribution, diameter, and zeta potential occurred. A deficiency in the silane integrity in the nanofilled and silorane composites seems to be affected by the material stage condition. The materials conditions tested in this study influenced the filler size distribution, the zeta potential, and integrity of the silane adsorbed on fillers in the nanofilled and silorane composites. Thus, this may result in a decrease of the clinical performance of aforementioned composites, in

  14. Efficacy and safety of a hyaluronic acid filler in subjects treated for correction of midface volume deficiency: a 24 month study

    Directory of Open Access Journals (Sweden)

    Callan P

    2013-03-01

    .1% being GAIS responders, respectively. At end of the study, 66/72 subjects were either satisfied or very satisfied with Voluma™, with 70/72 indicating that they would recommend the product to others. Adverse events were transient and infrequent, with injection site bruising and swelling being the most commonly reported.Conclusion: Voluma™ is safe and effective in the correction of mild to severe facial volume deficiency, achieving long-term clinically meaningful results. There was a high degree of satisfaction with the treatment outcome over the 24 months of the study.Keywords: hyaluronic acid, dermal fillers, volume deficit, volume deficiency, mid-face, malar

  15. SVOC exposure indoors: fresh look at dermal pathways.

    Science.gov (United States)

    Weschler, C J; Nazaroff, W W

    2012-10-01

    This paper critically examines indoor exposure to semivolatile organic compounds (SVOCs) via dermal pathways. First, it demonstrates that--in central tendency--an SVOC's abundance on indoor surfaces and in handwipes can be predicted reasonably well from gas-phase concentrations, assuming that thermodynamic equilibrium prevails. Then, equations are developed, based upon idealized mass-transport considerations, to estimate transdermal penetration of an SVOC either from its concentration in skin-surface lipids or its concentration in air. Kinetic constraints limit air-to-skin transport in the case of SVOCs that strongly sorb to skin-surface lipids. Air-to-skin transdermal uptake is estimated to be comparable to or larger than inhalation intake for many SVOCs of current or potential interest indoors, including butylated hydroxytoluene, chlordane, chlorpyrifos, diethyl phthalate, Galaxolide, geranyl acetone, nicotine (in free-base form), PCB28, PCB52, Phantolide, Texanol and Tonalide. Although air-to-skin transdermal uptake is anticipated to be slow for bisphenol A, we find that transdermal permeation may nevertheless be substantial following its transfer to skin via contact with contaminated surfaces. The paper concludes with explorations of the influence of particles and dust on dermal exposure, the role of clothing and bedding as transport vectors, and the potential significance of hair follicles as transport shunts through the epidermis. Human exposure to indoor pollutants can occur through dietary and nondietary ingestion, inhalation, and dermal absorption. Many factors influence the relative importance of these pathways, including physical and chemical properties of the pollutants. This paper argues that exposure to indoor semivolatile organic compounds (SVOCs) through the dermal pathway has often been underestimated. Transdermal permeation of SVOCs can be substantially greater than is commonly assumed. Transport of SVOCs from the air to and through the skin is

  16. Aluminum Lithium Alloy 2195 Fusion Welding Improvements with New Filler Wire

    Science.gov (United States)

    Russell, C.

    2001-01-01

    The objective of this research was to assess the B218 weld filler wire for Super Lightweight External Tank production, which could improve current production welding and repair productivity. We took the following approaches: (1) Perform a repair weld quick look evaluation between 4043/B218 and B218/B218 weld filler wire combinations and evaluation tensile properties for planished and unplanished conditions; and (2) Perform repair weld evaluation on structural simulation panel using 4043-B218 and B218/B218 weld filler wire combinations and evaluation tensile and simulated service fracture properties for planished and unplanished conditions.

  17. Effect of Filler Concentration on Thermal Stability of Vinyl Copolymer Elastomer (VCE) Composites

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Dali [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hubbard, Kevin Mark [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Devlin, David James [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Henderson, Kevin C. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pacheco, Robin Montoya [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-03-06

    To study the thermal stability of vinyl copolymer elastomer (VCE) in its composite form, systematic TGA characterizations were conducted in both nonisothermal and isothermal modes. The effects of filler concentration on the aging behaviors of the VCE/filler composites were investigated under nitroplasticizer (NP) environment. FTIR characterization was used to probe the structural changes in the VCE polymer before and after the thermal treatments. This study suggests that the filler concentration significantly deteriorates the thermal stability of NP at a moderate temperature (< 70 °C). The degradation of NP, in turn, accelerates the aging process of the VCE polymer in its composite form.

  18. Wear resistance of layers hard faced by the high-alloyed filler metal

    OpenAIRE

    Dušan Arsić; Vukić Lazić; Ruzica R. Nikolic; Milan Mutavdžić; Srbislav Aleksandrović; Milan Djordjević

    2016-01-01

    The objective of this work was to determine the wear resistance of layers hard faced by the high-alloyed filler metal, with or without the austenite inter-layer, on parts that operate at different sliding speeds in conditions without lubrication. The samples were hard faced with the filler metal E 10-UM-60-C with high content of C, Cr and W. Used filler metal belongs into group of alloys aimed for reparatory hard facing of parts damaged by abrasive and erosive wear and it is characterized by ...

  19. Enhancing the Ductility of Laser-Welded Copper-Aluminum Connections by using Adapted Filler Materials

    Science.gov (United States)

    Weigl, M.; Albert, F.; Schmidt, M.

    Laser micro welding of direct copper-aluminum connections typically leads to the formation of intermetallic phases and an embrittlement of the metal joints. By means of adapted filler materials it is possible to reduce the brittle phases and thereby enhance the ductility of these dissimilar connections. As the element silicon features quite a well compatibility with copper and aluminum, filler materials based on Al-Si and Cu-Si alloys are used in the current research studies. In contrast to direct Cu-Al welds, the aluminum filler alloy AlSi12 effectuates a more uniform element mixture and a significantly enhanced ductility.

  20. SIFAT MEKANIK KOMPOSIT COKELAT BATANG DENGAN FILLER BIJI METE

    Directory of Open Access Journals (Sweden)

    P A Wiguna

    2015-07-01

    Full Text Available Bahan komposit yang banyak dijumpai di masyarakat umumnya terbuat dari material berat seperti, logam, keramik, atau polimer. Pada bahan pangan terdapat pula yang termasuk ke dalam kategori material komposit, diantaranya adalah cracker, cookie, kue pie, chasew chocolate, dan lain sebagianya. Diantara komposit bahan pangan tersebut yang paling banyak digemari sebagai makanan camilan adalah  cokelat. Hal menarik yang dikaji pada studi ini berkaitan dengan sifat mekanik komposit cokelat yaitu kekuatan tekan dari komposit tersebut. Komposit ini terbuat dari bahan makanan cokelat dengan variasi  fraksi massa mete sebagai filler yaitu 13 %, 17%, 20%, 23%, 26 %, dan 29%. Matriks yang digunakan adalah cokelat jenis dark chocolate. Sifat mekanik yang dikaji adalah kuat tekan pada komposit cokelat batang. Parameter ini diukur untuk mengetahui ukuran maksimum beban yang dapat diterima komposit tersebut. Komposit yang memiliki kekuatan tekan terbesar ada pada cokelat batang dengan fraksi massa mete 29 % yaitu sebesar 2,81 MPa. Hal ini menunjukkan  bahwa variasi fraksi massa mete berpengaruh pada sifat mekanik material komposit karena berkaitan dengan perilaku distribusi partikel. Kuat tekan komposit cokelat teramati meningkat dengan kenaikan jumlah biji mete pada cokelat batang.Generally, the composite materials found in the civilization are made from heavy materials, e.g. metals, ceramics, and polymers. In fact, the composite material also found in food, such as crackers, cookies, pies, and cashew chocolates. Cashew chocolates usually consumed as the most favourite snack. The most interesting object from this study is related with the mechanical composite characteristic of the chocolate, i.e. compressive strength. Chocolate composite is made from chocolate with variety of cashew mass fraction as the filler, i.e. 13 %, 17%, 20%, 23%, 26 %, and 29%. In this study, the composite matrix was a dark chocolate, whereas the mechanical characteristic determined

  1. Effect of using fly ash as alternative filler in hot mix asphalt

    Directory of Open Access Journals (Sweden)

    Raja Mistry

    2016-09-01

    Full Text Available This study investigates the effect of using fly ash (FA in asphalt mixture as replacement of common filler. In view of the same, samples were prepared for different bitumen content (3.5−6.5% at 0.5% increments by using 2% hydrated lime (HL in control mix as well as varying percentage of FA ranging from 2 to 8% as alternative filler in modified mixes. The optimum bitumen content (OBC was then determined for all the mix by Marshall mix design. Experimental results indicated higher stability value with lower OBC for the mixture having 4% FA as optimum filler content in comparison with conventional mix and standard specification. So this study discuss the feasibility of using FA as alternative filler instead of HL in asphalt concrete mix by satisfying the standard specification.

  2. Evaluation on construction quality of pit filler material of cavern type radioactive waste disposal facility

    International Nuclear Information System (INIS)

    Takechi, Shin-ichi; Yokozeki, Kosuke; Shimbo, Hiroshi; Terada, Kenji; Akiyama, Yoshihiro; Yada, Tsutomu; Tsuji, Yukikazu

    2014-01-01

    The pit filler material of the underground cavern-type radioactive waste disposal facility, which is poured directly around the radioactive waste packages where high temperature environment is assumed by their decay heat, is concerned to be adversely affected on the filling behavior and its hardened properties. There also are specific issues that required quality of construction must be achieved by unmanned construction with remote operation, because the pit filler construction shall be done under radiation environment. In this paper, the mix proportion of filler material is deliberated with filling experiments simulating high temperature environment, and also the effect of temperature on hardened properties are confirmed with high temperature curing test. Subsequently, the feasibility of unmanned construction method of filler material by pumping, and by movable bucket, are comparatively discussed through a real size demonstration. (author)

  3. Characterization of granite and limestone powders for use as fillers in bituminous mastics dosage

    Directory of Open Access Journals (Sweden)

    BRENO BARRA

    2014-06-01

    Full Text Available This paper discusses the importance of studies on materials known as fillers from different mineral origins, used in asphalt mixes, specifically in the formulation of mastics. The research was carried out on samples of limestone and granite rock filler and asphalt binder (50/70. The samples were evaluated through semiquantitative chemical analyses by X-ray fluorescence, granulometry by low angle laser emission, scanning electron microscopy, softening point tests, penetration tests, and aggregate-asphalt binder and aggregate-mastic adhesion tests. The results highlighted convergent trends, indicating that the active behavior of the fillers in the mastic formulation is not related to the size of the particles, but rather to their form, surface texture, specific surface area and mineralogical nature, allowing the filler activity concept to be divided into two components: physical (hardening and chemical (adhesion.

  4. Application of waste bulk moulded composite (BMC) as a filler for isotactic polypropylene composites.

    Science.gov (United States)

    Barczewski, Mateusz; Matykiewicz, Danuta; Andrzejewski, Jacek; Skórczewska, Katarzyna

    2016-05-01

    The aim of this study was to produce isotactic polypropylene based composites filled with waste thermosetting bulk moulded composite (BMC). The influence of BMC waste addition (5, 10, 20 wt%) on composites structure and properties was investigated. Moreover, additional studies of chemical treatment of the filler were prepared. Modification of BMC waste by calcium stearate (CaSt) powder allows to assess the possibility of the production of composites with better dispersion of the filler and more uniform properties. The mechanical, processing, and thermal properties, as well as structural investigations were examined by means of static tensile test, Dynstat impact strength test, differential scanning calorimetry (DSC), wide angle X-ray scattering (WAXS), melt flow index (MFI) and scanning electron microscopy (SEM). Developed composites with different amounts of non-reactive filler exhibited satisfactory thermal and mechanical properties. Moreover, application of the low cost modifier (CaSt) allows to obtain composites with better dispersion of the filler and improved processability.

  5. A survey of the bacterial diversity in the cup filler of dental chair units.

    Science.gov (United States)

    Silva, Vítor; Figueira, Vânia; Figueiral, Helena; Manaia, Célia M

    2011-07-01

    Water from the cup filler of dental chair units (CFDC) was observed to contain sphingomonads, environmental mycobacteria and methylobacteria, among other minor bacteria. Some of the bacteria detected are recognized opportunistic pathogens. Some of these, tended to persist over time.

  6. A comparative study of the thermal interface materials with graphene and boron nitride fillers

    Science.gov (United States)

    Kargar, F.; Salgado, R.; Legedza, S.; Renteria, J.; Balandin, A. A.

    2014-09-01

    We report the results of an experimental study that compares the performance of graphene and boron nitride flakes as fillers in the thermal interface materials. The thickness of both fillers varied from a single atomic plane to about a hundred. The measurements have been conducted using a standard TIM tester. Our results show that the addition of a small fraction of graphene (f=4 wt%) to a commercial thermal interface material increases the resulting apparent thermal conductivity substantially stronger than the addition of boron nitride. The obtained data suggest that graphene and fewlayer graphene flakes couple better to the matrix materials than the boron nitride fillers. A combination of both fillers can be used to increase the thermal conductivity while controlling the electrical conduction.

  7. Carbon dioxide selective mixed matrix composite membrane containing ZIF-7 nano-fillers

    KAUST Repository

    Li, Tao; Pan, Yichang; Peinemann, Klaus-Viktor; Lai, Zhiping

    2013-01-01

    Mixed matrix materials made from selective inorganic fillers and polymers are very attractive for the manufacturing of gas separation membranes. But only few of these materials could be manufactured into high-performance asymmetric or composite

  8. Hybrid 2D-3D modelling of GTA welding with filler wire addition

    KAUST Repository

    Traidia, Abderrazak; Roger, Frederic; Guyot, Evelyne; Schroeder, Jeanne; Lubineau, Gilles

    2012-01-01

    , with relatively good accuracy and reasonable computational cost. Also, an original approach to simulate the effect of immersing a cold filler wire in the weld pool is presented. The simulation results reveal two important observations. First, the weld pool depth

  9. Cerebral Angiographic Findings of Cosmetic Facial Filler-related Ophthalmic and Retinal Artery Occlusion

    OpenAIRE

    Kim, Yong-Kyu; Jung, Cheolkyu; Woo, Se Joon; Park, Kyu Hyung

    2015-01-01

    Cosmetic facial filler-related ophthalmic artery occlusion is rare but is a devastating complication, while the exact pathophysiology is still elusive. Cerebral angiography provides more detailed information on blood flow of ophthalmic artery as well as surrounding orbital area which cannot be covered by fundus fluorescein angiography. This study aimed to evaluate cerebral angiographic features of cosmetic facial filler-related ophthalmic artery occlusion patients. We retrospectively reviewed...

  10. Enhanced Thermal, Mechanical and Morphological Properties of CNT/HDPE Nanocomposite Using MMT as Secondary Filler

    OpenAIRE

    M. E. Ali Mohsin; Agus Arsad; Othman Y. Alothman

    2014-01-01

    This study explains the influence of secondary filler on the dispersion of carbon nanotube (CNT) reinforced high density polyethylene (HDPE) nanocomposites (CNT/HDPE). In order to understand the mixed-fillers system, Montmorillonite (MMT) was added to CNT/HDPE nanocomposites. It was followed by investigating their effect on the thermal, mechanical and morphological properties of the aforesaid nanocomposite. Incorporation of 3 wt% each of MMT into CNT/HDPE nanocomposite resulted to the increas...

  11. Influence of Natural, Synthetic Polymers and Fillers on sustained release matrix tablets of Pregabalin

    OpenAIRE

    Vijaya Durga. K; Ashok Kumar. P; Suresh V Kulkarni

    2013-01-01

    The objective of the present study was to develop sustained release matrix tablets of Pregabalin for the treatment of neuropathic pain and epilepsy. The tablets were prepared by wet granulation and formulated using drug with Hydrophilic, hydrophobic, synthetic, natural polymers and 4 different fillers were used. The effect of Polymer concentration, combination and fillers on drug release rate was analyzed for the formulations F-1 to F-17. The tablets were subjected to physicochemical studies,...

  12. Glans Penis Augmentation Using Hyaluronic Acid Gel as an Injectable Filler

    OpenAIRE

    Moon, Du Geon; Kwak, Tae Il; Kim, Je Jong

    2015-01-01

    Glans penis augmentation (GPA) has received little attention from experts despite the existence of a subset of patients who may be dissatisfied with a small glans or poor tumescence of the glans during erection. Recently, GPA using an injectable filler or implantation of a graft or filler has been developed. Despite a demanding injection technique and inevitable uneven undulation of the glandular surface, GPA using injectable hyaluronic acid (HA) gel is a novel and useful therapy and an effec...

  13. Effects of conductive fillers on temperature distribution of asphalt pavements

    International Nuclear Information System (INIS)

    Chen Mingyu; Wu Shaopeng; Zhang Yuan; Wang Hong

    2010-01-01

    The sun provides a cheap and abundant source of clean and renewable energy. Solar cells have been used to capture this energy and generate electricity. A more useful form of the solar cell would be asphalt pavements, which get heated up by solar radiation. Graphite powders are utilized as thermal conductive fillers to make an asphalt collector conductive so as to improve the efficiency of the asphalt collector. Accounting for the important application conditions and evaluating the effects of the heat conductive materials and the solar energy absorbability of the conductive asphalt collector, a finite element model has been developed to predict temperature distributions in the conductive asphalt solar collector. In this study, an experimental validation exercise was conducted using the measured data taken from full-depth asphalt slabs. Validation results showed that the model can satisfactorily predict the temperature distributions in asphalt concrete slabs. The optimal depth is 25-50 mm for placing pipes that serve as the heat exchanger. Meanwhile, the effect of the surroundings on the solar energy potential of the asphalt collector was noticeable.

  14. Sustainable materials used as stone column filler: A short review

    Science.gov (United States)

    Zukri, Azhani; Nazir, Ramli

    2018-04-01

    Stone columns (also known as granular piles) are one of the methods for soft soil stabilization and typically used to increase bearing capacity and stability of slope.; Apart from decreasing the compressibility of loose and fine graded soils, it also accelerates the consolidation effect by improving the drainage path for pore water pressure dissipation and reduces the liquefaction potential of soils during earthquake event. Stone columns are probably the most “natural” ground treatment method or foundation system in existence to date. The benefit of stone columns is owing to the partial replacement of compressible soil by more competent materials such as stone aggregate, sand and other granular materials. These substitutes also act as reinforcement material, hence increasing overall strength and stiffness of the soft soil. Nowadays, a number of research has been conducted on the behaviour and performance of stone columns with various materials utilized as column filler replacing the normal aggregate. This paper will review extensively on previously conducted research on some of the materials used as stone column backfill materials, its suitability and the effectiveness as a substitute for regular aggregates in soft soil improvement works.

  15. Magnetic and viscoelastic response of elastomers with hard magnetic filler

    International Nuclear Information System (INIS)

    Kramarenko, E Yu; Chertovich, A V; Semisalova, A S; Makarova, L A; Perov, N S; Khokhlov, A R; Stepanov, G V

    2015-01-01

    Magnetic elastomers (MEs) based on a silicone matrix and magnetically hard NdFeB particles have been synthesized and their magnetic and viscoelastic properties have been studied depending on the size and concentration of magnetic particles and the magnetizing field. It has been shown that magnetic particles can rotate in soft polymer matrix under applied magnetic field, this fact leading to some features in both magnetic and viscoelastic properties. In the maximum magnetic field used magnetization of MEs with smaller particles is larger while the coercivity is smaller due to higher mobility of the particles within the polymer matrix. Viscoelastic behavior is characterized by long relaxation times due to restructuring of the magnetic filler under the influence of an applied mechanical force and magnetic interactions. The storage and loss moduli of magnetically hard elastomers grow significantly with magnetizing field. The magnetic response of the magnetized samples depends on the mutual orientation of the external magnetic field and the internal sample magnetization. Due to the particle rotation within the polymer matrix, the loss factor increases abruptly when the magnetic field is turned on in the opposite direction to the sample magnetization, further decreasing with time. Moduli versus field dependences have minimum at non-zero field and are characterized by a high asymmetry with respect to the field direction. (paper)

  16. Isolation of intact sub-dermal secretory cavities from Eucalyptus

    Directory of Open Access Journals (Sweden)

    Goodger Jason QD

    2010-09-01

    Full Text Available Abstract Background The biosynthesis of plant natural products in sub-dermal secretory cavities is poorly understood at the molecular level, largely due to the difficulty of physically isolating these structures for study. Our aim was to develop a protocol for isolating live and intact sub-dermal secretory cavities, and to do this, we used leaves from three species of Eucalyptus with cavities that are relatively large and rich in essential oils. Results Leaves were digested using a variety of commercially available enzymes. A pectinase from Aspergillus niger was found to allow isolation of intact cavities after a relatively short incubation (12 h, with no visible artifacts from digestion and no loss of cellular integrity or cavity contents. Several measurements indicated the potential of the isolated cavities for further functional studies. First, the cavities were found to consume oxygen at a rate that is comparable to that estimated from leaf respiratory rates. Second, mRNA was extracted from cavities, and it was used to amplify a cDNA fragment with high similarity to that of a monoterpene synthase. Third, the contents of the cavity lumen were extracted, showing an unexpectedly low abundance of volatile essential oils and a sizeable amount of non-volatile material, which is contrary to the widely accepted role of secretory cavities as predominantly essential oil repositories. Conclusions The protocol described herein is likely to be adaptable to a range of Eucalyptus species with sub-dermal secretory cavities, and should find wide application in studies of the developmental and functional biology of these structures, and the biosynthesis of the plant natural products they contain.

  17. Design of an elastin-layered dermal regeneration template.

    Science.gov (United States)

    Mithieux, Suzanne M; Weiss, Anthony S

    2017-04-01

    We demonstrate a novel approach for the production of tunable quantities of elastic fibers. We also show that exogenous tropoelastin is rate-limiting for elastin synthesis regardless of the age of the dermal fibroblast donor. Additionally, we provide a strategy to further enhance synthesis by older cells through the application of conditioned media. We show that this approach delivers an elastin layer on one side of the leading dermal repair template for contact with the deep dermis in order to deliver prefabricated elastic fibers to a physiologically appropriate site during subsequent surgery. This system is attractive because it provides for the first time a viable path for sufficient, histologically detectable levels of patient elastin into full-thickness wound sites that have until now lacked this elastic underlayer. The scars of full thickness wounds typically lack elasticity. Elastin is essential for skin elasticity and is enriched in the deep dermis. This paper is significant because it shows that: (1) we can generate elastic fibers in tunable quantities, (2) tropoelastin is the rate-limiting component in elastin synthesis in vitro, (3) we can generate elastin fibers regardless of donor age, (4) we describe a novel approach to further increase the numbers and thickness of elastic fibers for older donors, (5) we improve on Integra Dermal Regeneration Template and generate a new hybrid biomaterial intended to subsequently surgically deliver these elastic fibers, (6) the elastic fiber layer is presented on the side of Integra that is intended for delivery into its physiologically appropriate site i.e. the deep dermis. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  18. Evaluation of dermal wound healing activity of synthetic peptide SVVYGLR.

    Science.gov (United States)

    Uchinaka, Ayako; Kawaguchi, Naomasa; Ban, Tsuyoshi; Hamada, Yoshinosuke; Mori, Seiji; Maeno, Yoshitaka; Sawa, Yoshiki; Nagata, Kohzo; Yamamoto, Hirofumi

    2017-09-23

    SVVYGLR peptide (SV peptide) is a 7-amino-acid sequence with angiogenic properties that is derived from osteopontin in the extracellular matrix and promotes differentiation of fibroblasts to myofibroblast-like cells and the production of collagen type Ⅲ by cardiac fibroblasts. However, the effects of SV peptide on dermal cells and tissue are unknown. In this study, we evaluated the effects of this peptide in a rat model of dermal wound healing. The synthetic SV peptide was added to dermal fibroblasts or keratinocytes, and their cellular motility was evaluated. In an in vivo wound healing exeriment, male rats aged 8 weeks were randomly assigned to the SV peptide treatment, non-treated control, or phosphate-buffered saline (PBS) groups. Wound healing was assessed by its repair rate and histological features. Scratch assay and cell migration assays using the Chemotaxicell method showed that SV peptide significantly promoted the cell migration in both fibroblasts and keratinocytes. In contrast the proliferation potency of these cells was not affected by SV peptide. In the rat model, wound healing progressed faster in the SV peptide-treated group than in the control and PBS groups. The histopathological analyses showed that the SV peptide treatment stimulated the migration of fibroblasts to the wound area and increased the number of myofibroblasts. Immunohistochemical staining showed a marked increase of von Willebland factor-positive neomicrovessels in the SV peptide-treated group. In conclusion, SV peptide has a beneficial function to promote wound healing by stimulating granulation via stimulating angiogenesis, cell migration, and the myofibroblastic differentiation of fibroblasts. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Brazing of zirconia to titanium using Ag-Cu and Au-Ni filler alloys

    Directory of Open Access Journals (Sweden)

    Jean S. Pimenta

    2013-12-01

    Full Text Available Advanced ceramic is usually joined to metal by the well-known direct brazing process, where costly active filler alloys can be considered a limitation. Brazing using active-metal-free filler alloy as insert between the joint components is an attempt to overcome it. The active metal diffusion from the titanium member through the bulk of molten filler to the ceramic was responsible to produce an active filler alloy in loco and promote reduction of the zirconium oxide to improve wetting on the ceramic surface. Unalloyed titanium was joined in a high-vacuum furnace (<3x10-5 mbar to yttria-tetragonal zirconia polycristals (Y-TZP and zirconia partially stabilized with magnesia (Mg-PSZ, where commercial fillers Ag-28Cu and Au-18Ni with respective thermal cycles were evaluated. Helium gas leak detection test was performed at the ceramic/metal interface at room temperature; samples from reliable vacuum tight joints were examined by microstructural analysis techniques and energy dispersive X-ray analysis at the joint cross-section. Tight joints were produced with eutectic Ag-Cu filler, revealing an intermetallic layer and a dark reaction layer near the ceramic surface; titanium diffusion was efficient for superficial chemical interactions between individual components. Brazing joints were also tested using three-point flexure testing.

  20. Avoiding and Treating Blindness From Fillers: A Review of the World Literature.

    Science.gov (United States)

    Beleznay, Katie; Carruthers, Jean D A; Humphrey, Shannon; Jones, Derek

    2015-10-01

    As the popularity of soft tissue fillers increases, so do the reports of adverse events. The most serious complications are vascular in nature and include blindness. To review the cases of blindness after filler injection, to highlight key aspects of the vascular anatomy, and to discuss prevention and management strategies. A literature review was performed to identify all the cases of vision changes from filler in the world literature. Ninety-eight cases of vision changes from filler were identified. The sites that were high risk for complications were the glabella (38.8%), nasal region (25.5%), nasolabial fold (13.3%), and forehead (12.2%). Autologous fat (47.9%) was the most common filler type to cause this complication, followed by hyaluronic acid (23.5%). The most common symptoms were immediate vision loss and pain. Most cases of vision loss did not recover. Central nervous system complications were seen in 23.5% of the cases. No treatments were found to be consistently successful in treating blindness. Although the risk of blindness from fillers is rare, it is critical for injecting physicians to have a firm knowledge of the vascular anatomy and to understand key prevention and management strategies.

  1. Case Reports of Adipose-derived Stem Cell Therapy for Nasal Skin Necrosis after Filler Injection

    Directory of Open Access Journals (Sweden)

    Ha Min Sung

    2012-01-01

    Full Text Available With the gradual increase of cases using fillers, cases of patients treated by non-medical professionals or inexperienced physicians resulting in complications are also increasing. We herein report 2 patients who experienced acute complications after receiving filler injections and were successfully treated with adipose-derived stem cell (ADSCs therapy. Case 1 was a 23-year-old female patient who received a filler (Restylane injection in her forehead, glabella, and nose by a non-medical professional. The day after her injection, inflammation was observed with a 3×3 cm skin necrosis. Case 2 was a 30-year-old woman who received a filler injection of hyaluronic acid gel (Juvederm on her nasal dorsum and tip at a private clinic. She developed erythema and swelling in the filler-injected area A solution containing ADSCs harvested from each patient's abdominal subcutaneous tissue was injected into the lesion at the subcutaneous and dermis levels. The wounds healed without additional treatment. With continuous follow-up, both patients experienced only fine linear scars 6 months postoperatively. By using adipose-derived stem cells, we successfully treated the acute complications of skin necrosis after the filler injection, resulting in much less scarring, and more satisfactory results were achieved not only in wound healing, but also in esthetics.

  2. Nano-fillers to tune Young’s modulus of silicone matrix

    International Nuclear Information System (INIS)

    Xia Lijin; Xu Zhonghua; Sun Leming; Caveney, Patrick M.; Zhang Mingjun

    2013-01-01

    In this study, we investigated nanoparticles, nanofibers, and nanoclays for their filler effects on tuning the Young’s modulus of silicone matrix, a material with broad in vivo applications. Nano-fillers with different shapes, sizes, and surface properties were added into silicone matrix, and then their filler effects were evaluated through experimental studies. It was found that spherical nanoparticles could clearly improve Young’s modulus of the silicone matrix, while nanoclays and carbon nanofibers had limited effects. Smaller spherical nanoparticles were better in performance compared to larger nanoparticles. In addition, enhanced distribution of the nanoparticles in the matrix has been observed to improve the filler effect. In order to minimize toxicity of the nanoparticles for in vivo applications, spherical nanoparticles coated with amine, acid, or hydroxide groups were also investigated, but they were found only to diminish the filler effect of nanoparticles. This study demonstrated that spherical nanoparticles could serve as fillers to tune Young’s modulus of silicone matrix for potential applications in medicine.

  3. Delayed-onset complications of facial soft tissue augmentation with permanent fillers in 85 patients.

    Science.gov (United States)

    Kadouch, Jonathan A; Kadouch, Daniel J; Fortuin, Shai; van Rozelaar, Leo; Karim, Refaat B; Hoekzema, Rick

    2013-10-01

    To evaluate factors influencing the onset and type of adverse events in patients injected with permanent fillers in the face and to propose a therapeutic strategy for these complications. A prospectively attained series of 85 patients with delayed-onset complications after facial injection with permanent fillers underwent clinical follow-up and treatment of the complications. Lag times until onset and type of delayed-onset complication varied according to filler material. In 28% (n = 24) of the cases, patients reported the onset of complications after dental procedures, additional injections with fillers, or other invasive treatments in the facial area. Forty-eight (57%) patients required invasive treatment. Abscess formation was significantly more frequent in patients with human immunodeficiency virus infection and facial lipoatrophy (p = .001). The intrinsic characteristics of the injected filler and the immune status of the patient play important roles in the diversity of time of onset and type of delayed-onset adverse events observed. It seems that invasive facial or oral procedures in the vicinity of filler depots can provoke such complications. We propose a strategy for treating these complications and advise great caution when using permanent filling agents. © 2013 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.

  4. Morphological characterization of ceramic fillers made from Indonesian natural sand as restorative dental materials

    Science.gov (United States)

    Karlina, E.; Susra, S.; Fatmala, Y.; Hartoyo, H. M.; Takarini, V.; Usri, K.; Febrida, R.; Djustiana, N.; Panatarani, C.; Joni, I. M.

    2018-02-01

    Dental composite as restorative dental materials can be reinforced using ceramic fillers. Homogeneous distribution of filler particles shall improve its mechanical properties. This paper presents the results of the preliminary study on the ZrO2-Al2O3-SiO2 ceramic fillers made from Indonesian natural sand that can increase the mechanical properties of dental composite. The synthesis was done using zirconium silicate sand (ZrSiO4) and aluminium oxide (Al2O3) precursors, which dissolved together with 70:30 weight ratios. Two types of sand were used: (1) manufactured sand (mesh #80) and (2) natural sand (mesh #400). The samples then heated in the furnace at 1100 °C for 8 hours. The morphological characterization was then evaluated using JEOL Scanning Electron Microscope (SEM) for the surface structure that analyze particles size and distribution. Ceramic fillers made from natural sand is homogenous, well distributed with average particle size of 5-10 µm. Comparably, ceramic filler made from the manufactured sand is heterogeneous, poorly distributed and appear as agglomerates with average particle size are 30-50 µm. The results suggest that ceramic fillers made from natural sand demonstrate better character to represent as a functional restorative dental material.

  5. Plasma-modified graphene nanoplatelets and multiwalled carbon nanotubes as fillers for advanced rubber composites

    International Nuclear Information System (INIS)

    Sicinski, M; Gozdek, T; Bielinski, D M; Kleczewska, J; Szymanowski, H; Piatkowska, A

    2015-01-01

    In modern rubber industry, there still is a room for new fillers, which can improve the mechanical properties of the composites, or introduce a new function to the material. Modern fillers like carbon nanotubes or graphene nanoplatelets (GnP), are increasingly applied in advanced polymer composites technology. However, it might be hard to obtain a well dispersed system for such systems. The polymer matrix often exhibits higher surface free energy (SFE) level with the filler, which can cause problems with polymer-filler interphase adhesion. Filler particles are not wet properly by the polymer, and thus are easier to agglomerate. As a consequence, improvement in the mechanical properties is lower than expected. In this work, multi-walled carbon nanotubes (MWCNT) and GnP surface were modified with low-temperature plasma. Attempts were made to graft some functionalizing species on plasma-activated filler surface. The analysis of virgin and modified fillers’ SFE was carried out. MWCNT and GnP rubber composites were produced, and ultimately, their morphology and mechanical properties were studied. (paper)

  6. Thermal properties of oil palm nano filler/kenaf reinforced epoxy hybrid nanocomposites

    Science.gov (United States)

    Saba, N.; Paridah, M. T.; Abdan, K.; Ibrahim, N. A.

    2016-11-01

    The aim of this research study was to fabricate nano oil palm empty fruit bunch (OPEFB)/kenaf/epoxy hybrid nanocomposites and to make comparative study on the thermal properties of nano OPEFB/kenaf/epoxy hybrid nanocomposites with the montmorillonite (MMT)/kenaf/epoxy hybrid nanocomposites and organically modified MMT (OMMT)/kenaf/epoxy hybrid nanocomposites. Epoxy based kenaf hybrid nanocomposites was prepared by dispersing the nano filler (nano OPEFB filler, MMT, OMMT) at 3% loading through high speed mechanical stirrer followed by hand lay-up technique. Thermal properties of hybrid nanocomposites were analyzed through thermogravimetry analyzer (TGA), and differential scanning calorimetry (DSC). Obtained results specified that addition of nano OPEFB filler improves the thermal stability and char yield of kenaf/epoxy composites. Furthermore, the increase in decomposition temperature by the nano OPEFB filler was quite comparable to the MMT/kenaf/epoxy but relatively less than OMMT/kenaf/epoxy hybrid nanocomposites. We concluded from overall consequences that the nano OPEFB filler can be used as the promising and innovative alternative of existing expensive nano filler, with relatively lesser impact on the environment having marked pronounced impact on the construction, automotive, aerospace, electronics and semiconducting sectors as future industries based on bio-wastes with satisfactory light weight and thermal stability on other side.

  7. Optimization of cement composites with the use of fillers from the Chechen Republic fields

    Directory of Open Access Journals (Sweden)

    Balatkhanova Elita Mahmudovna

    Full Text Available The fillers together with binders take part in microstructure formation of matrix basis and contact zones of a composite. The advantage of cement matrix structure with a filler is that inner defects are localized in it - microcracks, macropores and capillary pores, as well as that their quantity, their sizes and stress concentration decrease. Structure formation of filled cement composites is based on the processes taking place in the contact of liquid and stiff phases, which means, it depends on the quantitative relation of the cement, fillers and water, and also dispersivity and physical and chemical activity of the fillers. In the article the authors offer research results of the processes of hydration and physical-mechanical properties of cement composites with fillers from the fields of the Chechen Republic. Research results of heat cement systems are presented, modified by fine fillers. Optimal composition of cement composites filled with powders of quartz, sandstone, river and a mountain limestone of different particle size composition, characterized by a high strength, are obtained.

  8. Atypical post kala azar dermal leishmaniasis with "muzzle area" swelling.

    Science.gov (United States)

    Arora, Sandeep; Bal, Arvinder Singh; Baveja, Sukriti; Sood, Aradhana; Rathi, Khushi Ram; Patil, Pradeep

    2015-01-01

    A 50-year-old male presented with recurrent swelling of the muzzle area of the face with history of low-grade intermittent fever of 3 year duration managed variously with antibiotics, systemic steroids, and antituberculous therapy. Skin biopsy revealed a granulomatous infiltration negative for acid-fast bacilli and leishmania donovan bodies. Immunochromatography test for rK 39 antigen and polymerase chain reaction for leishmania was positive. He was diagnosed as a case of post kala azar dermal leishmaniasis, managed with injection sodium stibogluconate and followed-up thereafter.

  9. Chemical stabilization of polymers: Implications for dermal exposure to additives.

    Science.gov (United States)

    Bartsch, N; Girard, M; Schneider, L; Weijgert, V Van De; Wilde, A; Kappenstein, O; Vieth, B; Hutzler, C; Luch, A

    2018-04-16

    Technical benefits of additives in polymers stand in marked contrast to their associated health risks. Here, a multi-analyte method based on gas chromatography coupled to tandem mass spectrometry (GC-MS/MS) was developed to quantify polymer additives in complex matrices such as low-density polyethylene (LDPE) and isolated human skin layers after dermal exposure ex vivo. That way both technical aspects and dermal exposure were investigated. The effects of polymer additivation on the material were studied using the example of LDPE. To this end, a tailor-made polymer was applied in aging studies that had been furnished with two different mixtures of phenol- and diarylamine-based antioxidants, plasticizers and processing aids. Upon accelerated thermo-oxidative aging of the material, the formation of LDPE degradation products was monitored with attenuated total reflectance-Fourier transformed infrared (ATR-FTIR) spectroscopy. Compared to pure LDPE, a protective effect of added antioxidants could be observed on the integrity of the polymer. Further, thermo-oxidative degradation of the additives and its kinetics were investigated using LDPE or squalane as matrix. The half-lives of additives in both matrices revealed significant differences between the tested additives as well as between LDPE and squalane. For instance, 2-tert-butyl-6-[(3-tert-butyl-2-hydroxy-5-methylphenyl)methyl]-4-methylphenol (Antioxidant 2246) showed a half-life 12 times lower when incorporated in LDPE as compared to squalane. As a model for dermal exposure of consumers, human skin was brought into contact with the tailor-made LDPE containing additives ex vivo in static Franz diffusion cells. The skin was then analyzed for additives and decomposition products. This study proved 10 polymer additives of diverse pysicochemical properties and functionalities to migrate out of the polymer and eventually overcome the intact human skin barrier during contact. Moreover, their individual distribution within

  10. Defense against dermal exposures is only skin deep

    DEFF Research Database (Denmark)

    Nielsen, Jesper Bo; Nielsen, Flemming; Sørensen, Jens Ahm

    2007-01-01

    study demonstrates that a limited damage to the skin significantly increases the permeability coefficient (K (p)) as well as total percutaneous penetration of chemicals, and most significantly for those compounds that due to their physicochemical characteristics (the most hydrophilic as well as the most...... compartments is affected by the physicochemical characteristics of the chemicals as well as by the integrity of the skin. This observation may have implications when evaluating the possibility of removing chemicals from the skin through different cleansing procedures following unintended dermal exposures....

  11. Effect of microemulsions on cell viability of human dermal fibroblasts

    Science.gov (United States)

    Li, Juyi; Mironava, Tatsiana; Simon, Marcia; Rafailovich, Miriam; Garti, Nissim

    Microemulsions are optically clear, thermostable and isotropic mixture consisting of water, oil and surfactants. Their advantages of ease preparation, spontaneous formation, long-term stability and enhanced solubility of bioactive materials make them great potentials as vehicles in food and pharmaceutical applications. In this study, comparative in vitro cytotoxicity tests were performed to select a best formulation of microemulsion with the least toxicity for human dermal fibroblasts. Three different kinds of oils and six different kinds of surfactants were used to form microemulsions by different ratios. The effect of oil type and surfactant type as well as their proportions on cell proliferation and viability were tested.

  12. Effect of Mineral Filler Type and Particle Size on the Engineering Properties of Stone Mastic Asphalt Pavements

    Directory of Open Access Journals (Sweden)

    R Muniandy

    2013-12-01

    Full Text Available This study examines four types of industrial and by-product waste fillers, namely limestone dust (LSD, which was the reference filler; ceramic waste dust (CWD; coal fly ash (CFA, and steel slag mixture (SSD. The filler consisted of an aggregate (10% of total weight with three proportions: 100% passing 75μm, 50% passing 75μm/20μm, and 100% passing 20μm. Comprehensive laboratory tests were performed to determine the impact of different types and particle sizes of fillers on the engineering and mechanical properties of fine mastics and stone mastic asphalt mixture. The results indicate that the application of industrial by-products used as fillers improves the engineering properties of stone mastic asphalt mixtures. The increased stiffness due to the addition of the filler is represented by an increase in the softening point, viscosity, stability, and resilient modulus, as well as a decrease in penetration. The optimum asphalt content increased with the decrease in filler particle size for LSD and SSD, and decreased for CWD and CFA. It was also determined that the filler type and particle size has a significant effect on the mixture properties. Among these three proportions, the samples prepared with the filler size proportion of 50/50 gave the best value in terms of stability, Marshall quotient, and resilient modulus than the other filler size proportions.

  13. Changes in dermal papilla structures due to aging in the facial cheek region.

    Science.gov (United States)

    Mizukoshi, K; Yonekura, K; Futagawa, M; Nakamura, T; Hirayama, K; Takahashi, K

    2015-05-01

    In the past, it has been possible to measure the dermal papilla structures which are undulations between the epidermis and dermis by noninvasive method. However, almost all of previous studies were not intended to measure facial skin but another site of body. Here, we investigated age-dependent alterations for dermal papilla structures in the facial cheek region after elucidating the difference of characteristics between the body site. The surface of the dermis was observed under scanning electron microscope (SEM) using face and abdominal skin biopsy samples. A total of 90 Japanese women were investigated by in vivo confocal laser microscope (CLSM). The number and the shape in the horizontal cross-sectional images of the dermal papilla were analyzed. The facial skin had different characteristics in comparison to the abdominal skin by SEM observation. Under CLSM observation, we found abnormal dermal papilla structures which were accompanied by spots or enlarged pore areas and eliminated these structures from our analysis. We revealed a decrease in the number of normal dermal papilla structures with age and large individual differences at younger ages. We found abnormal dermal papilla structures and differences in the dermal papilla structures between face and other body site. With these taken into consideration, we could precisely investigate the aging alteration of normal dermal papilla structures in the face. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Measurements of Dermal Uptake of Nicotine Directly from Air and Clothing

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Morrison, Glenn; Weschler, Charles J.

    2016-01-01

    Dermal uptake directly from air is a significant contributor to total exposure for certain organic compounds, and has been recently experimentally verified for two phthalates. The objective of the current study was to investigate whether airborne nicotine can be dermally absorbed. Two bare-skinne...

  15. Dermal exposure assessment to benzene and toluene using charcoal cloth pads

    NARCIS (Netherlands)

    Wendel de Joode, B. van; Tielemans, E.; Vermeulen, R.; Wegh, H.; Kromhout, H.

    2005-01-01

    Charcoal cloth pads have been used to assess volatile chemicals on the skin in a laboratory setting; however, they have not yet been applied to measure dermal exposure in occupational settings. This study aimed at evaluating whether charcoal pads can be used to assess dermal exposure to benzene and

  16. DERMAL, ORAL, AND INHALATION PHARMACOKINETICS OF METHYL TERTIARY BUTYL ETHER (MTBE) IN HUMAN VOLUNTEERS

    Science.gov (United States)

    Methyl tertiary butyl ether (MTBE), a gasoline additive, used to increase octane and reduce carbon monoxide emissions and ozone precursors has contaminated drinking water leading to exposure by oral, inhalation, and dermal routes. To determine its dermal, oral, and inhalation ki...

  17. DERMAL, ORAL AND INHALATION PHARMACOKINETICS OF METHYL TERTIARY-BUTYL ETHER (MTBE) IN HUMAN VOLUNTEERS

    Science.gov (United States)

    Methyl tertiary butyl ether (MTBE), a gasoline additive used to increase octane and reduce carbon monoxide emissions and ozone precursors, has contaminated drinking water and can lead to exposure by oral, inhalation, and dermal routes. To determine its dermal, oral, and inhal...

  18. Harmonization of future needs for dermal exposure assessment and modeling : a workshop report

    NARCIS (Netherlands)

    Marquart, H.; Maidment, S.; Mcclaflin, J.L.; Fehrenbacher, M.C.

    2001-01-01

    Dermal exposure assessment and modeling is still in early phases of development. This article presents the results of a workshop organized to harmonize the future needs in this field. Methods for dermal exposure assessment either assess the mass of contaminant that is transferred to the skin, or the

  19. A dermal model for spray painters, part I : subjective exposure modelling of spray paint deposition

    NARCIS (Netherlands)

    Brouwer, D.H.; Semple, S.; Marquart, J.; Cherrie, J.W.

    2001-01-01

    The discriminative power of existing dermal exposure models is limited. Most models only allow occupational hygienists to rank workers between and within workplaces according to broad bands of dermal exposure. No allowance is made for the work practices of different individuals. In this study a

  20. Liposome-containing Hibiscus sabdariffa calyx extract formulations with increased antioxidant activity, improved dermal penetration and reduced dermal toxicity.

    Science.gov (United States)

    Pinsuwan, Sirirat; Amnuaikit, Thanaporn; Ungphaiboon, Suwipa; Itharat, Arunporn

    2010-12-01

    Hibiscus sabdariffa Linn, or Roselle, is a medicinal plant used extensively in traditional Thai medicine since ancient times. The extracts of Roselle calyces possess antioxidant activity and have potential for development as active ingredients in cosmetic products. However the limitations of using Roselle extracts in cosmetics are its low skin permeation and dermal irritation. Liposome technology is an obvious approach that might overcome these problems. Liposome formulations of standardized Roselle extracts were developed with various lipid components. The formulation showing the highest entrapment efficiency was selected for stability, skin permeation and dermal irritability studies. The liposome formulation with the highest entrapment efficiency (83%) and smalôlest particle size (332 mm) was formulated with phosphatidylcholine from soybean (SPC): Tween 80: deoxycholic acid (DA); 84:16:2.5 weight ratio, total lipid of 200 g/mL and 10% w/v Roselle extract in final liposomal preparation. This liposome formulation was found to be stable after storage at 4 degrees C, protected from light, for 2 months. The in vitro skin permeation studies, using freshly excised pig skin and modified Franz-diffusion cells, showed that the liposome formulation was able to considerably increased the rate of permeation of active compounds in Roselle extracts compared to the Roselle extract solution. The in vivo dermal irritability testing on rabbit skin showed that the liposome formulation dramatically decreased skin irritability compared to the unformulated extract. These results showed that the liposomes containing Roselle extracts had good stability, high entrapment efficacy, increased skin permeation and low skin irritation.

  1. Acellular dermal matrix based nipple reconstruction: A modified technique

    Directory of Open Access Journals (Sweden)

    Raghavan Vidya

    2017-09-01

    Full Text Available Nipple areolar reconstruction (NAR has evolved with the advancement in breast reconstruction and can improve self-esteem and, consequently, patient satisfaction. Although a variety of reconstruction techniques have been described in the literature varying from nipple sharing, local flaps to alloplastic and allograft augmentation, over time, loss of nipple projection remains a major problem. Acellular dermal matrices (ADM have revolutionised breast reconstruction more recently. We discuss the use of ADM to act as a base plate and strut to give support to the base and offer nipple bulk and projection in a primary procedure of NAR with a local clover shaped dermal flap in 5 breasts (4 patients. We used 5-point Likert scales (1 = highly unsatisfied, 5 = highly satisfied to assess patient satisfaction. Median age was 46 years (range: 38–55 years. Nipple projection of 8 mm, 7 mm, and 7 mms were achieved in the unilateral cases and 6 mm in the bilateral case over a median 18 month period. All patients reported at least a 4 on the Likert scale. We had no post-operative complications. It seems that nipple areolar reconstruction [NAR] using ADM can achieve nipple projection which is considered aesthetically pleasing for patients.

  2. Dermal transfer quantification of nanoparticles from nano-enabled surfaces

    DEFF Research Database (Denmark)

    Mackevica, Aiga; Olsson, Mikael Emil; Mines, Paul D.

    2018-01-01

    ). The dermal transfer testing by wipe sampling and analytical approach used in this study demonstrates that wipe testing in combination with spICP-MS analysis can provide both qualitative data in terms of mass and number-based NP release, as well as particle characterization in terms of NP size distribution...... and characterize NP release from keyboard covers and freshly painted surfaces, in terms of mass and number concentration, as well as released particle size distribution through the use of spICP-MS. Three types of NPs were selected for method validation testing, Ag, TiO2, and CuO; and, the particle extraction from...... wipes was found to be efficient for Ag and CuO, but not for TiO2 particles. Thereafter, potential dermal transfer was tested by wipe sampling for two nanoAg-containing silicon keyboard covers, and wood painted with nanoCuO-containing paint. AgNP release was observed for one of the keyboard cover types...

  3. Effect of Arctium lappa (burdock) extract on canine dermal fibroblasts.

    Science.gov (United States)

    Pomari, Elena; Stefanon, Bruno; Colitti, Monica

    2013-12-15

    Although the biological activities of Arctium lappa (burdock) have been already investigated in human and other species, data evaluating the molecular mechanisms have not been reported in the dog. In this study we analyzed for the first time the effect of a root extract of burdock on molecular responses in canine dermal fibroblasts with H2O2 stimulation (H group), with burdock treatment (B group) and with H2O2 stimulation and burdock treatment (BH group), using RNAseq technology. Differentially expressed genes (P<0.05) of H, B and BH groups in comparison to the untreated sample (negative control, C group) were identified with MeV software and were functional annotated and monitored for signaling pathways and candidate biomarkers using the Ingenuity Pathways Analysis (IPA). The expression profile of canine dermal fibroblasts treated with burdock extract with or without H2O2 stimulation, showed an up-regulation of mitochondrial superoxide dismutase (SOD2), disheveled 3 (DVL3) and chondroitin sulfate N-acetylgalactosaminyltransferase 2 (CSGALNACT2). The data suggested that burdock has implications in cell adhesion and gene expression with the modulation of Wnt/β catenin signaling and Chondroitin Sulphate Biosynthesis that are particularly important for the wound healing process. © 2013 Elsevier B.V. All rights reserved.

  4. Assessment of dermal exposure to bitumen condensate among road paving and mastic crews with an observational method

    NARCIS (Netherlands)

    Agostini, M.; Fransman, W.; Vocht, F.D.; Joode, B.V.W.D.; Kromhout, H.

    2011-01-01

    Objective: To assess dermal exposure to bitumen condensate among road pavers and indoor mastic workers in multiple crews using a semi-quantitative observational method [DeRmal Exposure Assessment Method (DREAM)].Methods: Two skilled observers assessed dermal exposure to bitumen condensate among 85

  5. Novel manufacturing process of nanoparticle/Al composite filler metals of tungsten inert gas welding by accumulative roll bonding

    Energy Technology Data Exchange (ETDEWEB)

    Fattahi, M., E-mail: fattahi.put@gmail.com [Technical Inspection Engineering Department, Petroleum University of Technology, Abadan (Iran, Islamic Republic of); Noei Aghaei, V. [Aerospace Engineering Department, Sharif University of Technology, Tehran (Iran, Islamic Republic of); Dabiri, A.R. [Technical Inspection Engineering Department, Petroleum University of Technology, Abadan (Iran, Islamic Republic of); Amirkhanlou, S. [Young Researchers and Elite Club, Najafabad Branch, Islamic Azad University, Najafabad (Iran, Islamic Republic of); Akhavan, S.; Fattahi, Y. [Materials Engineering Department, Isfahan University of Technology, Isfahan (Iran, Islamic Republic of)

    2015-11-11

    In the present work, accumulative roll bonding (ARB) was used as an effective method for manufacturing nanoparticle/Al composite filler metals of tungsten inert gas (TIG) welding. After welding, the distribution of ceramic nanoparticles and mechanical properties of welds were investigated. By applying ARB, ceramic nanoparticles were uniformly dispersed in the composite filler metals. Consequently, the welds produced by these filler metals had a uniform dispersion of ceramic nanoparticles in their compositions. The test results showed that the yield strength of welds was greatly increased when using the nanoparticle/Al composite filler metals. The improvement in the yield strength was attributed to the coefficient of thermal expansion mismatch and Orowan strengthening mechanisms. Therefore, according to the results presented in this paper, it can be concluded that the nanoparticle/Al composite filler metals can serve as a novel filler metal for TIG welding of aluminum and its alloys.

  6. Safety of radiofrequency treatment over human skin previously injected with medium-term injectable soft-tissue augmentation materials: a controlled pilot trial.

    Science.gov (United States)

    Alam, Murad; Levy, Ross; Pajvani, Urvi; Pavjani, Urvi; Ramierez, James A; Guitart, Joan; Veen, Heather; Gladstone, Hayes B

    2006-03-01

    Several soft-tissue augmentation materials are now available for reduction of nasolabial fold creases and perioral rhytides. Nasolabial folds and perioral rhytides can also be improved by skin tightening delivered by non-ablative radiofrequency (RF) treatment. The purpose of this study was to assess the safety of RF treatment over skin areas recently injected with medium-term injectable soft-tissue augmentation materials. Five subjects were assigned to the experimental arm (augmentation materials plus RF) and one to the control arm (augmentation materials alone). Each subject received injections of 0.3 mL of hyaluronic acid derivative (Restylane) and calcium hydroxylapatite (Radiesse) 3 cm apart on the upper inner arm. Two weeks later, two non-overlapping passes of RF (Thermage ThermaCool TC) were delivered at 63.5 setting with medium-fast 1.5 cm2 tip over injected sites in all of the experimental subjects. Punch skin biopsies were obtained 3 days later from each of the two injection sites on each subject. Light microscopy and digital photomicrographs obtained at low, medium, and high power showed no difference between filler materials in experimental and control subjects. In both cases filler was evident at the deep dermal-subcutaneous junction. Nodule formation, foreign body extravasation, or hemorrhage/clot was not observed grossly or histologically. Subjects and physicians did not report any difference in signs and symptoms between the experimental and control arms. Slightly increased transitory pain was noted when RF was delivered over filler versus over normal skin. Applying RF treatment over the same area 2 weeks after deep dermal injection with hyaluronic acid derivatives or calcium hydroxylapatite does not appear to cause gross morphological changes in the filler material or surrounding skin. Further studies with different parameters are necessary to confirm these findings. 2006 Wiley-Liss, Inc.

  7. Development of compatibilized SBR and EPR nanocomposites containing dual filler system

    International Nuclear Information System (INIS)

    Rajasekar, R.; Nayak, G.C.; Malas, A.; Das, C.K.

    2012-01-01

    Highlights: ► Nanoclay is dispersed in non-polar rubbers by utilizing a polar compatibilizer. ► Effect of dual fillers [nanoclay and carbon black] on the rubber properties. ► Comparison of the results of single and dual filler containing rubber compounds. -- Abstract: The study described in this paper is an analysis of the role of a compatibilizer for dispersing organically modified nanoclay in styrene butadiene rubber (SBR) and ethylene propylene rubber (EPR) matrices. The normal mixing of non-polar rubbers and organically modified nanoclay may not lead to improved distribution of the nanofiller in the rubbery matrix. Hence, a polar rubber such as epoxidized natural rubber (ENR) can be used as a compatibilizer for dispersing nanoclay in the non-polar rubber matrices. ENR–organically modified nanoclay composites (EC) were prepared by solution mixing. The nanoclay used in this study is Cloisite 20A. The obtained ENR–nanoclay composites were incorporated in SBR and EPR matrices along with carbon black. The morphological studies proved the intercalation of nanoclay platelets in ENR and further incorporation of EC in SBR and EPR matrices leads to partial exfoliation of nanoclay platelets. A curing study demonstrated faster scorch time, cure time and increased maximum torque for the compatibilized SBR and EPR nanocomposites containing a dual filler system compared to the control. Dynamic mechanical thermal analysis showed increase in storage modulus for the SBR and EPR compounds containing dual fillers compared to rubber compounds containing pure and single filler. The same compounds show substantial improvement in mechanical properties. The tensile fractured surface of the rubber compounds containing single and dual filler observed by scanning electron microscopy, (SEM) showed highly rough and irregular fracture paths, which proved the physical interaction between filler and rubber.

  8. Influence of different fillers on the properties of an experimental vinyl polysiloxane

    Directory of Open Access Journals (Sweden)

    Débora Könzgen MEINCKE

    2016-01-01

    Full Text Available Abstract The aim of the study was to evaluate the effect of the incorporation of different fillers on an experimental vinyl polysiloxane (VPS at two different concentrations, 20% and 40%. Different fillers were added to an experimental VPS. The study was developed in two stages: (i incorporation of fillers in different concentrations: (a 20 wt% fillers, and (b 40 wt%. The fillers were added to experimental VPS and mixed with a speed mixer; (ii characterization of experimental VPS; after the base paste and catalyst paste were mixed, the experimental VPS was used to make specimens specifically for each test, which were stored at 23°C for 24 hours. The tests were designed according to the specific standardization for the analysis of tensile strength, detail reproduction, Shore A hardness, and elastic recovery. For analysis of filler size pattern, scanning electron microscopy at 1500× magnification was used. The aerosil OX-50 40% (AE, and pure aluminum hydroxide 40% (PAH groups presented the highest tensile strength and Shore A hardness values. However, those were the only groups that did not present continuous detail reproduction of an intersection of 20 μm line. The elastic recovery was not statistically significant. The undesirable characteristics of VPS (lowest Shore A hardness and tensile strength were observed when it was added to the composition of acrylic polymer (AP and fiberglass (FG in both concentrations, 20% and 40%. In groups AE and PAH, agglomerates of nanofillers were shown in SEM micrography, while the other groups presented different shapes and fillers sizes.

  9. Influence of mineral fillers on the rheological response of polymer-modified bitumens and mastics

    Directory of Open Access Journals (Sweden)

    F. Cardone

    2015-12-01

    Full Text Available The rheological properties of the bituminous components (bitumen and bituminous mastic within asphalt mixtures contribute significantly to the major distresses of flexible pavements (i.e. rutting, fatigue and low temperature cracking. Asphalt mixtures are usually composed of mastic-coated aggregates rather than pure bitumen-coated aggregates. The purpose of this study is to investigate the effects of mineral fillers on the rheological behaviour of several polymer-modified bitumens (PMBs through laboratory mixing. A neat bitumen and two types of polymers (elastomeric and plastomeric were used to produce PMBs, and two fillers with different minerals (limestone and basalt were selected to obtain mastics. The dynamic shear rheometer (DSR and bending beam rheometer (BBR were used to characterize the rheological properties of PMBs and mastics. In particular, multiple stress creep recovery (MSCR tests were performed to evaluate the rutting potential at high temperatures, whereas BBR tests were carried out to investigate the low temperature behaviour of these materials. BBR results for unmodified mastics show that the increase of stiffness is similar regardless of the filler type, whereas results for polymer-modified mastics indicate that the degree of stiffening depends on the combination of filler/polymer types. MSCR results show that adding filler leads to a reduced susceptibility of permanent deformation and an enhanced elastic response, depending on the combination of filler/polymer types. Overall results suggest that a physical–chemical interaction between the filler and bitumen occurs, and that the interaction level is highly dependent on the type of polymer modification.

  10. The effect of chemical composition and granulation of Fe - based fillers on properties of metal resinous composite

    International Nuclear Information System (INIS)

    Janecki, J.; Dasiewicz, J.; Pawelec, Z.

    2000-01-01

    In this paper the authors present metal-resinous composites with Fe based fillers of various element constitution and granulation. The analysis of influence of filler type on coefficient of linear thermal expansion of composite materials was performed. Friction and wear tests (composite-bronze and composite-steel pairs) were carried out. It was stated that the thinner granulation of main filler has a positive effect on coefficient of linear thermal expansion and friction/wear characteristics. The presence of copper, nickel and molybdenum in the filler is beneficial for some properties of the composite. (author)

  11. Effect of filler types on physical, mechanical and microstructure of self compacting concrete and Flow-able concrete

    Directory of Open Access Journals (Sweden)

    Hafez E. Elyamany

    2014-06-01

    Full Text Available The objective of this study is to evaluate the effect of various filler types on the fresh and hardened properties of self-compacting concrete (SCC and Flow-able concrete. For this purpose, two groups of fillers were selected. The first group was pozzolanic fillers (silica fume and metakaolin while the second group was non-pozzolanic fillers (limestone powder, granite dust and marble dust. Cement contents of 400 kg/m3 and 500 kg/m3 were considered while the used filler material was 7.5%, 10% and 15%. Slump and slump flow, T50, sieve stability and bleeding tests were performed on fresh concrete. The studied hardened properties included unit weight, voids ratio, porosity, and water absorption and cube compressive strength. In addition, thermo-gravimetric analysis, X-ray diffraction analysis and scanning electronic microscope were performed. The test results showed that filler type and content have significant effect on fresh concrete properties where non-pozzolanic fillers improve segregation and bleeding resistance. Generally, filler type and content have significant effect on unit weight, water absorption and voids ratio. In addition, non-pozzolanic fillers have insignificant negative effect on concrete compressive strength. Finally, there was a good correlation between fresh concrete properties and hardened concrete properties for SCC and Flow-able concrete.

  12. Steam Cured Self-Consolidating Concrete and the Effects of Limestone Filler

    Science.gov (United States)

    Aqel, Mohammad A.

    The purpose of this thesis is to determine the effect and the mechanisms associated with replacing 15% of the cement by limestone filler on the mechanical properties and durability performance of self-consolidating concrete designed and cured for precast/prestressed applications. This study investigates the role of limestone filler on the hydration kinetics, mechanical properties (12 hours to 300 days), microstructural and durability performance (rapid chloride permeability, linear shrinkage, sulfate resistance, freeze-thaw resistance and salt scaling resistance) of various self-consolidating concrete mix designs containing 5% silica fume and steam cured at a maximum holding temperature of 55°C. This research also examines the resistance to delayed ettringite formation when the concrete is steam cured at 70°C and 82°C and its secondary consequences on the freeze-thaw resistance. The effect of several experimental variables related to the concrete mix design and also the curing conditions are examined, namely: limestone filler fineness, limestone filler content, cement type, steam curing duration and steam curing temperature. In general, the results reveal that self-consolidating concrete containing 15% limestone filler, steam cured at 55°C, 70°C and 82°C, exhibited similar or superior mechanical and transport properties as well as long term durability performance compared to similar concrete without limestone filler. When the concrete is steam cured at 55°C, the chemical reactivity of limestone filler has an important role in enhancing the mechanical properties at 16 hours (compared to the concrete without limestone filler) and compensating for the dilution effect at 28 days. Although, at 300 days, the expansion of all concrete mixes are below 0.05%, the corresponding freeze-thaw durability factors vary widely and are controlled by the steam curing temperature and the chemical composition of the cement. Overall, the material properties indicate that the use

  13. Prevention of microcracking by REM addition to alloy 690 filler metal in laser clad welds

    International Nuclear Information System (INIS)

    Okauchi, Hironori; Saida, Kazuyoshi; Nishimoto, Kazutoshi

    2011-01-01

    Effect of REM addition to alloy 690 filler metal on microcracking prevention was verified in laser clad welding. Laser clad welding on alloy 132 weld metal or type 316L stainless steel was conducted using the five different filler metals of alloy 690 varying the La content. Ductility-dip crack occurred in laser clad welding when La-free alloy 690 filler metal was applied. Solidification and liquation cracks occurred contrarily in the laser cladding weld metal when the 0.07mass%La containing filler metal was applied. In case of laser clad welding on alloy 132 weld metal and type 316L stainless steel, the ductility-dip cracking susceptibility decreased, and solidification/liquation cracking susceptibilities increased with increasing the La content in the weld metal. The relation among the microcracking susceptibility, the (P+S) and La contents in every weld pass of the laser clad welding was investigated. Ductility-dip cracks occurred in the compositional range (atomic ratio) of La/(P+S) 0.99(on alloy 132 weld metal), >0.90 (on type 316L stainless steel), while any cracks did not occur at La/(P+S) being between 0.21-0.99 (on alloy 132 weld metal) 0.10-0.90 (on type 316L stainless steel). Laser clad welding test on type 316L stainless steel using alloy 690 filler metal containing the optimum La content verified that any microcracks did not occurred in the laser clad welding metal. (author)

  14. Characterization of green composites from biobased epoxy matrices and bio-fillers derived from seashell wastes

    International Nuclear Information System (INIS)

    Fombuena, V.; Bernardi, L.; Fenollar, O.; Boronat, T.; Balart, R.

    2014-01-01

    Highlights: • Calcium carbonate from seashell is an attractive bio-filler in polymeric industry. • We examine composition and thermal properties of calcium carbonate from seashell. • Used with eco-friendly epoxy matrices provides a high renewable content material. • Addition of 30 wt.% of seashell bio-filler increase of over 50% in flexural modulus. • Calcium carbonate from seashell leads higher thermal stability materials. - Abstract: The seashells, a serious environmental hazard, are composed mainly by calcium carbonate, which can be used as filler in polymer matrix. The main objective of this work is the use of calcium carbonate from seashells as a bio-filler in combination with eco-friendly epoxy matrices thus leading to high renewable contents materials. Previously obtaining calcium carbonate, the seashells were washed and grinded. The powder obtained and the resin was characterized by DSC, TGA, X-ray diffraction (XRD), X-ray fluorescence spectroscopy (XRF), and rheology plate-plate. The results show that addition of 30 wt.% of seashell bio-filler increase mechanical properties as flexural modulus (over 50%) and hardness Shore D (over 6%) and thermal properties as an increase around 13% in glass transitions temperature. The results show that the addition of calcium carbonate from seashells is an effective method to increase mechanical properties of bio-composite and to reduce the residue of seashells from industrial production

  15. Effects of Inorganic Fillers on the Thermal and Mechanical Properties of Poly(lactic acid).

    Science.gov (United States)

    Liu, Xingxun; Wang, Tongxin; Chow, Laurence C; Yang, Mingshu; Mitchell, James W

    Addition of filler to polylactic acid (PLA) may affect its crystallization behavior and mechanical properties. The effects of talc and hydroxyapatite (HA) on the thermal and mechanical properties of two types of PLA (one amorphous and one semicrystalline) have been investigated. The composites were prepared by melt blending followed by injection molding. The molecular weight, morphology, mechanical properties, and thermal properties have been characterized by gel permeation chromatography (GPC), scanning electron microscope (SEM), instron tensile tester, thermogravimetric analysis (TGA), differential scanning calorimetry (DSC), and dynamic mechanical analysis (DMA). It was found that the melting blending led to homogeneous distribution of the inorganic filler within the PLA matrix but decreased the molecular weight of PLA. Regarding the filler, addition of talc increased the crystallinity of PLA, but HA decreased the crystallinity of PLA. The tensile strength of the composites depended on the crystallinity of PLA and the interfacial properties between PLA and the filler, but both talc and HA filler increased the toughness of PLA.

  16. Use of Almond Shells and Rice Husk as Fillers of Poly(Methyl Methacrylate) (PMMA) Composites.

    Science.gov (United States)

    Sabbatini, Alessandra; Lanari, Silvia; Santulli, Carlo; Pettinari, Claudio

    2017-07-28

    In recent years, wood fibres have often been applied as the reinforcement of thermoplastic materials, such as polypropylene, whereas their use in combination with thermosetting resin has been less widespread. This study concerns the production of PMMA-based composites by partly replacing alumina trihydrate (ATH) with wood waste fillers, namely rice husks and almond shells, which would otherwise be disposed by incineration. The amount of filler introduced was limited to 10% as regards rice husks and 10 or 15% almond shells, since indications provided by reactivity tests and viscosity measurements did not suggest the feasibility of total replacement of ATH. As a matter of fact, the introduction of these contents of wood waste filler in PMMA-based composite did not result in any significant deterioration of its mechanical properties (Charpy impact, Rockwell M hardness and flexural performance). Some reduction of these properties was only observed in the case of introduction of 15% almond shells. A further issue concerned the yellowing of the organic filler under exposure to UV light. On the other hand, a very limited amount of water was absorbed, never exceeding values around 0.6%, despite the significant porosity revealed by the filler's microscopic evaluation. These results are particularly interesting in view of the application envisaged for these composites, i.e., wood replacement boards.

  17. Influence of fillers on mechanical properties of filled rubbers during ageing by irradiation

    International Nuclear Information System (INIS)

    Planes, Emilie

    2008-01-01

    The understanding of the evolution of mechanical properties and the prediction of the lifetime of material environment is a recurring problem. This question is very important to develop polymer formulations used for electrical cables in nuclear power plants. Thus it is important to know the evolution of materials when they are submitted to usual conditions in nuclear power plants. There are in literature some studies concerning the ageing by gamma irradiation of unfilled elastomer but the addition of fillers in the material can have consequences on the evolution of the mechanical properties during irradiation. Thus this work concerns the study of the ageing by gamma irradiation of filled rubbers and the identification of the role of fillers in the degradation mechanisms. The studied matrix, which commonly used for the type of application is EPDM. The fillers are: nano-scopic silica and aluminium trihydrate. Their surfaces have been treated in order to understand the role of filler-matrix interfaces during ageing. To evaluate the influence of fillers on the degradation mechanisms and on the evolution of the mechanical properties, the evolution during ageing of these materials filled or not has been studied for an ageing by irradiation: they have been physico-chemically, micro-structurally and mechanically characterized at various levels of ageing [fr

  18. The Influence of Unusual Materials as Prospective Fillers in the Hot Mix Asphalt

    Science.gov (United States)

    Cavalcate Ferrão, Wallace; Moizinho, Joel Carlos

    2017-10-01

    Among the factors that influence directly the durability of the asphaltic layer on pavements, the type and percentage of filler in the hot mix asphalt pavement (HMA) is a great player. The most traditional fillers, the Portland cement and the hydrated lime, are well known for resisting to weather variations and adding extra features to the hot mixtures. The glass powder, the cladding waste (gotten from clay bricks), the ashes of rice husks and laterite powder are proposed as substitutes to the traditional ones. The materials have been sieved and classified by fitting the powder on the filler grain size required by Brazilian Rules, eventually they have been tested with asphalt 50/70. The glass powder performed a Thermic Susceptibility Index (IST) of -0.69 for 5% in weight of filler and -0.75 for 10% in weight of filler, proving that this material satisfies the Brazilian specification DNIT-EM 095/2006; on the other hand, the laterite powder presented an IST of -0.61 for 5% and 0.32 for 10%. After executing the Softening Point, Penetration and Flash Point tests, it has been confirmed that the glass and laterite powder are recommended materials as potential substitutes to the Portland cement, however the first one performs better under balmy temperatures due to its negative IST; the cladding powder and the rice husks turns the mixtures too rigid and breakable on percentages close to 10%.

  19. Bio-based polyurethane composite foams with inorganic fillers studied by thermogravimetry

    International Nuclear Information System (INIS)

    Hatakeyema, Hyoe; Tanamachi, Noriko; Matsumura, Hiroshi; Hirose, Shigeo; Hatakeyama, Tatsuko

    2005-01-01

    Bio-based polyurethane (PU) composite foams filled with various inorganic fillers, such as barium sulfate (BaSO 4 ), calcium carbonate (CaCO 3 ) and talc were prepared using polyols, such as diethylene glycol, triethylene glycol and polyethylene glycol (molecular weight ca. 200) containing molasses and lignin. Reactive hydroxyl groups in plant components and above polyols were used as reaction sites. Morphological observation of fracture surface of composites was carried out by scanning electron microscopy. Thermal properties of bio-based PU composites were examined by thermogravimetry. It was found that the above composites decompose in two stages reflecting decomposition of organic components. Decomposition temperature increased with increasing filler content, when plant components were homogenously mixed with inorganic fillers. Activation energy calculated by Ozawa-Wall-Flynn method was ca. 150 kJ mol -1 . The durability of composites was predicted using kinetic data. Calculated values indicate that composites with fillers are more durable than that of those without fillers at a moderate temperature region

  20. Study of piezoelectric filler on the properties of PZT-PVDF composites

    Science.gov (United States)

    Matei, Alina; Å¢ucureanu, Vasilica; Vlǎzan, Paulina; Cernica, Ileana; Popescu, Marian; RomaniÅ£an, Cosmin

    2017-12-01

    The ability to obtain composites with desired functionalities is based on advanced knowledge of the processes synthesis and of the structure of piezoceramic materials, as well the incorporation of different fillers in selected polymer matrix. Polyvinylidene fluoride (PVDF) is a fluorinated polymer with excellent mechanical and electric properties, which it was chosen as matrix due to their applications in a wide range of industrial fields [1-4]. The present paper focuses on the development of composites based on PZT particles as filler obtained by conventional methods and PVDF as polymer matrix. The synthesis of PVDF-PZT composites was obtained by dispersing the ceramic powders in a solution of PVDF in N-methyl-pyrrolidone (NMP) under mechanical mixing and ultrasonication, until a homogenous mixture is obtained. The properties of the piezoceramic fillers before and after embedding into the polymeric matrix were investigated by Fourier transform infrared spectrometry, field emission scanning electron microscopy and X-ray diffraction. In the FTIR spectra, appear a large number of absorption bands which are exclusive of the phases from PVDF matrix confirming the total embedding of PZT filler into matrix. Also, the XRD pattern of the composites has confirmed the presence of crystalline phases of PVDF and the ceramic phase of PZT. The SEM results showed a good distribution of fillers in the matrix.

  1. Physical, structural and thermomechanical properties of oil palm nano filler/kenaf/epoxy hybrid nanocomposites

    Energy Technology Data Exchange (ETDEWEB)

    Saba, N., E-mail: naheedchem@gmail.com [Laboratory of Biocomposite Technology, Institute of Tropical Forestry and Forest Products(INTROP), Universiti Putra Malaysia, 43400 UPM Serdang, Selangor (Malaysia); Paridah, M.T. [Laboratory of Biocomposite Technology, Institute of Tropical Forestry and Forest Products(INTROP), Universiti Putra Malaysia, 43400 UPM Serdang, Selangor (Malaysia); Abdan, K. [Department of Biological and Agricultural Engineering, Faculty of Engineering, Universiti Putra Malaysia, 43400 UPM Serdang Selangor (Malaysia); Ibrahim, N.A. [Department of Chemistry, Faculty of Science, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor (Malaysia)

    2016-12-01

    The present research study deals with the fabrication of kenaf/epoxy hybrid nanocomposites by the incorporation of oil palm nano filler, montmorillonite (MMT) and organically modified montmorillonite (OMMT) at 3% loading, through hand lay-up technique. Effect of adding different nano fillers on the physical (density), structural [X-ray diffraction (XRD)] and thermomechanical analysis (TMA) of kenaf/epoxy composites were carried out. Density results revealed that the incorporation of nano filler in the kenaf/epoxy composites increases the density which in turn increases the hardness of the hybrid nanocomposites. XRD analysis confirmed the presence of nano fillers in the structure of their respective fabricated hybrid nanocomposites. All hybrid nanocomposites displayed lower coefficient of thermal expansion (CTE) with respect to kenaf/epoxy composites. Overall results predicted that the properties improvement in nano OPEFB/kenaf/epoxy was quite comparable to MMT/kenaf/epoxy but relatively lesser to OMMT/kenaf/epoxy hybrid nanocomposites and higher with respect to kenaf/epoxy composites. The improvement ascribed due to improved interfacial bonding or cross linking between kenaf fibers and epoxy matrix by addition of nano filler. - Highlights: • Nano OPEFB/kenaf/epoxy hybrid nanocomposites were fabricated by hand lay-up. • Effect of nano OPEFB on density & structure of kenaf/epoxy were investigated. • Thermal expansion coefficients of kenaf/epoxy and hybrid nanocomposites evaluated. • Comparative studies were made with MMT and OMMT kenaf/epoxy hybrid nanocomposites.

  2. Application of amorphous filler metals in production of fusion reactor high heat flux components

    Energy Technology Data Exchange (ETDEWEB)

    Kalin, B A [Moskovskij Inzhenerno-Fizicheskij Inst., Moscow (Russian Federation); Fedotov, V T [Moskovskij Inzhenerno-Fizicheskij Inst., Moscow (Russian Federation); Grigoriev, A E [Moskovskij Inzhenerno-Fizicheskij Inst., Moscow (Russian Federation); Sevriukov, O N [Moskovskij Inzhenerno-Fizicheskij Inst., Moscow (Russian Federation); Pliushev, A N [Moskovskij Inzhenerno-Fizicheskij Inst., Moscow (Russian Federation); Skuratov, L A [Moskovskij Inzhenerno-Fizicheskij Inst., Moscow (Russian Federation); Polsky, V I [Moskovskij Inzhenerno-Fizicheskij Inst., Moscow (Russian Federation); Yakushin, V L [Moskovskij Inzhenerno-Fizicheskij Inst., Moscow (Russian Federation); Virgiliev, Yu S [State Research Institute of Graphite, Electrodnaya St. 2, 115524 Moscow (Russian Federation); Vasiliev, V L [TRINITI, Troitsk, 142092 Moscow District (Russian Federation); Tserevitinov, S S [TRINITI, Troitsk, 142092 Moscow District (Russian Federation)

    1995-03-01

    Amorphous ribbon-type filler metals represent a promising facility for fastening heterogeneous materials together. The advantage results from the homogeneity of element and phase compositions and the strictly specified geometrical dimensions of such fillers. Amorphous fillers Zr-Ti-Fe-Be, Zr-Ti-Ni-Cu and Ti-Zr-Ni-Cu and microcrystalline fillers Al-Si and Cu-Sn-Mn-In-Ni were produced by quenching at a rate of about 10{sup 6}Ks{sup -1}. Brazing of graphite with metals (Cu+MPG-6, Cu+RGT, Mo+MIG-1, V+MIG-1, V+RGT) was accomplished using ribbon-type fillers. Two types of metal-based samples were produced in the form of plates and rakes. The rakes were made by brazing three small graphite bars to the metal, the 2mm space between the bars being 0.25 of the bar height. The results of metallographic studies of the brazing zone and of tests on brazed structures treated by pulsed energy fluxes are discussed. (orig.).

  3. Structural Studies of dielectric HDPE+ZrO2 polymer nanocomposites: filler concentration dependences

    Science.gov (United States)

    Nabiyev, A. A.; Islamov, A. Kh; Maharramov, A. M.; Nuriyev, M. A.; Ismayilova, R. S.; Doroshkevic, A. S.; Pawlukojc, A.; Turchenko, V. A.; Olejniczak, A.; Rulev, M. İ.; Almasan, V.; Kuklin, A. I.

    2018-03-01

    Structural properties of HDPE+ZrO2 polymer nanocomposites thin films of 80-100μm thicknesses were investigated using SANS, XRD, Laser Raman and FTIR spectroscopy. The mass fraction of the filler was 1, 3, 10, and 20%. Results of XRD analysis showed that ZrO2 powder was crystallized both in monoclinic and in cubic phase under normal conditions. The percentages of monoclinic and cubic phase were found to be 99.8% and 0.2%, respectively. It was found that ZrO2 nanoparticles did not affect the main crystal and chemical structure of HDPE, but the degree of crystallinity of the polymer decreases with increasing concentration of zirconium oxide. SANS experiments showed that at ambient conditions ZrO2 nanoparticles mainly distributed like mono-particles in the polymer matrix at all concentrations of filler.The structure of HDPE+ZrO2 does not changes up to 132°C at 1-3% of filler, excepting changing of the polymer structure at temperatures upper 82°C. At high concentrations of filler 10-20% the aggregation of ZrO2 nanoparticles occurs, forming domains of 2.5μm. The results of Raman and FTIR spectroscopy did not show additional specific chemical bonds between the filler and the polymer matrix. New peaks formation was not observed. These results suggest that core-shell structure does not exist in the polymer nanocomposite system.

  4. Facial soft-tissue fillers conference: assessing the state of the science.

    Science.gov (United States)

    Rohrich, Rod J; Hanke, C William; Busso, Mariano; Carruthers, Alastair; Carruthers, Jean; Fagien, Steven; Fitzgerald, Rebecca; Glogau, Richard; Greenberger, Phyllis E; Lorenc, Z Paul; Marmur, Ellen S; Monheit, Gary D; Pusic, Andrea; Rubin, Mark G; Rzany, Berthold; Sclafani, Anthony; Taylor, Susan; Weinkle, Susan; McGuire, Michael F; Pariser, David M; Casas, Laurie A; Collishaw, Karen J; Dailey, Roger A; Duffy, Stephen C; Edgar, Elizabeth Jan; Greenan, Barbara L; Haenlein, Kelly; Henrichs, Ronald A; Hume, Keith M; Lum, Flora; Nielsen, David R; Poulsen, Lisle; Shoaf, Lori; Schoaf, Lori; Seward, William; Begolka, Wendy Smith; Stanton, Robert G; Svedman, Katherine J; Thomas, J Regan; Sykes, Jonathan M; Wargo, Carol; Weiss, Robert A

    2011-04-01

    : The American Society of Plastic Surgeons and the American Academy of Dermatology, with the support of other sister societies, conducted the Facial Soft-Tissue Fillers: Assessing the State of the Science conference in December of 2009. The American Society of Plastic Surgeons and the American Academy of Dermatology established a panel of leading experts in the field of soft-tissue fillers-from researchers to clinicians-and other stakeholders for the conference to examine and discuss issues of patient safety, efficacy, and effectiveness in relation to the approved and off-label use of soft-tissue fillers, and other factors, including the training and level of experience of individuals administering fillers. This report represents the systematic literature review that examines comprehensively the available evidence and gaps in the evidence related to soft-tissue fillers, to inform and support the work of the state-of-the-science conference panel. This evidence-based medicine review will serve as the foundation for future evidence-based medicine reports in this growing field.

  5. Effects of Inorganic Fillers on the Thermal and Mechanical Properties of Poly(lactic acid

    Directory of Open Access Journals (Sweden)

    Xingxun Liu

    2014-01-01

    Full Text Available Addition of filler to polylactic acid (PLA may affect its crystallization behavior and mechanical properties. The effects of talc and hydroxyapatite (HA on the thermal and mechanical properties of two types of PLA (one amorphous and one semicrystalline have been investigated. The composites were prepared by melt blending followed by injection molding. The molecular weight, morphology, mechanical properties, and thermal properties have been characterized by gel permeation chromatography (GPC, scanning electron microscope (SEM, instron tensile tester, thermogravimetric analysis (TGA, differential scanning calorimetry (DSC, and dynamic mechanical analysis (DMA. It was found that the melting blending led to homogeneous distribution of the inorganic filler within the PLA matrix but decreased the molecular weight of PLA. Regarding the filler, addition of talc increased the crystallinity of PLA, but HA decreased the crystallinity of PLA. The tensile strength of the composites depended on the crystallinity of PLA and the interfacial properties between PLA and the filler, but both talc and HA filler increased the toughness of PLA.

  6. Physical, structural and thermomechanical properties of oil palm nano filler/kenaf/epoxy hybrid nanocomposites

    International Nuclear Information System (INIS)

    Saba, N.; Paridah, M.T.; Abdan, K.; Ibrahim, N.A.

    2016-01-01

    The present research study deals with the fabrication of kenaf/epoxy hybrid nanocomposites by the incorporation of oil palm nano filler, montmorillonite (MMT) and organically modified montmorillonite (OMMT) at 3% loading, through hand lay-up technique. Effect of adding different nano fillers on the physical (density), structural [X-ray diffraction (XRD)] and thermomechanical analysis (TMA) of kenaf/epoxy composites were carried out. Density results revealed that the incorporation of nano filler in the kenaf/epoxy composites increases the density which in turn increases the hardness of the hybrid nanocomposites. XRD analysis confirmed the presence of nano fillers in the structure of their respective fabricated hybrid nanocomposites. All hybrid nanocomposites displayed lower coefficient of thermal expansion (CTE) with respect to kenaf/epoxy composites. Overall results predicted that the properties improvement in nano OPEFB/kenaf/epoxy was quite comparable to MMT/kenaf/epoxy but relatively lesser to OMMT/kenaf/epoxy hybrid nanocomposites and higher with respect to kenaf/epoxy composites. The improvement ascribed due to improved interfacial bonding or cross linking between kenaf fibers and epoxy matrix by addition of nano filler. - Highlights: • Nano OPEFB/kenaf/epoxy hybrid nanocomposites were fabricated by hand lay-up. • Effect of nano OPEFB on density & structure of kenaf/epoxy were investigated. • Thermal expansion coefficients of kenaf/epoxy and hybrid nanocomposites evaluated. • Comparative studies were made with MMT and OMMT kenaf/epoxy hybrid nanocomposites.

  7. A facile approach to spinning multifunctional conductive elastomer fibres with nanocarbon fillers

    International Nuclear Information System (INIS)

    Seyedin, Shayan; Razal, Joselito M; Innis, Peter C; Wallace, Gordon G

    2016-01-01

    Electrically conductive elastomeric fibres prepared using a wet-spinning process are promising materials for intelligent textiles, in particular as a strain sensing component of the fabric. However, these fibres, when reinforced with conducting fillers, typically result in a compromise between mechanical and electrical properties and, ultimately, in the strain sensing functionality. Here we investigate the wet-spinning of polyurethane (PU) fibres with a range of conducting fillers such as carbon black (CB), single-walled carbon nanotubes (SWCNTs), and chemically converted graphene. We show that the electrical and mechanical properties of the composite fibres were strongly dependent on the aspect ratio of the filler and the interaction between the filler and the elastomer. The high aspect ratio SWCNT filler resulted in fibres with the highest electrical properties and reinforcement, while the fibres produced from the low aspect ratio CB had the highest stretchability. Furthermore, PU/SWCNT fibres presented the largest sensing range (up to 60% applied strain) and the most consistent and stable cyclic sensing behaviour. This work provides an understanding of the important factors that influence the production of conductive elastomer fibres by wet-spinning, which can be woven or knitted into textiles for the development of wearable strain sensors. (paper)

  8. Keratinocytes express fibrillin and assemble microfibrils: implications for dermal matrix organization.

    Science.gov (United States)

    Haynes, S L; Shuttleworth, C A; Kielty, C M

    1997-07-01

    Fibrillin-containing microfibrils are key architectural structures of the upper dermis and integral components of the dermal elastic fibre network. Microfibril bundles intercalate into the dermal-epithelial junction and provide an elastic connection between the dermal elastic fibre network and the epidermis. Immunohistochemical studies have suggested that they are laid down both at the dermal-epithelial junction and in the deep dermis. While dermal fibroblasts are responsible for deposition of the elastin and microfibrillar components that comprise the elastic fibres of the deep dermis, the cellular origin of the microfibril bundles that extrude from the dermal-epithelial junction is not well defined. We have used fresh tissues, freshly isolated epidermis and primary human and porcine keratinocyte cultures to investigate the possibility that keratinocytes are responsible for deposition of these microfibrils. We have shown that keratinocytes in vivo and in vitro synthesize both fibrillin-1 and fibrillin-2, and assemble beaded microfibrils concurrently with expression of basement membrane collagen. These observations suggest that keratinocytes co-ordinate the secretion, deposition and assembly of these distinct structural elements of the dermal matrix, and have important implications for skin remodelling.

  9. CTRP6 inhibits fibrogenesis in TGF-β1-stimulated human dermal fibroblasts

    International Nuclear Information System (INIS)

    Fan, Rong-hui; Zhu, Xiu-mei; Sun, Yao-wen; Peng, Hui-zi; Wu, Hang-li; Gao, Wen-jie

    2016-01-01

    Skin fibrosis is characterized by excessive proliferation of fibroblasts and overproduction of extracellular matrix (ECM). C1q/tumor necrosis factor-related protein 6 (CTRP6), a member of CTRPs, has been involved in the development of cardiac fibrosis. However, the function and detailed regulatory mechanism of CTRP6 in skin fibrosis remain unclear. The aim of this study was to investigate the effect of CTRP6 on the activation of human dermal fibroblasts. Our results showed that CTRP6 was lowly expressed in scar tissues and transforming growth factor-β1 (TGF-β1)-treated dermal fibroblasts. CTRP6 overexpression significantly inhibited the proliferation of dermal fibroblasts, as well as suppressed the expression of ECM in TGF-β1-treated dermal fibroblasts. Furthermore, CTRP6 overexpression markedly inhibited TGF-β1-induced phosphorylation of Smad3 in dermal fibroblasts. In conclusion, the data reported here demonstrate that CTRP6 is able to inhibit the proliferation and ECM expression in human dermal fibroblasts through suppressing the TGF-β1/Smad3 signaling pathway. These findings suggest that CTRP6 may be a potential therapeutic target for the prevention of skin fibrosis. -- Highlights: •CTRP6 expression was decreased in scar tissues and TGF-β1-treated dermal fibroblasts. •CTRP6 inhibits TGF-β1-induced the proliferation of dermal fibroblasts. •CTRP6 inhibits expression of collagen type I and α-SMA. •CTRP6 inhibits the activation of TGF-β1/Smad3 signaling pathway in dermal fibroblasts.

  10. Assessment of predictive dermal exposure to chemicals in the work environment

    Directory of Open Access Journals (Sweden)

    Agnieszka Jankowska

    2017-08-01

    Full Text Available Assessment of dermal exposure to chemicals in the work environment is problematic, mainly as a result of the lack of measurement data on occupational exposure to chemicals. Due to common prevalence of occupational skin exposure and its health consequences it is necessary to look for efficient solutions allowing for reliable exposure assessment. The aim of the study is to present predictive models used to assess non-measured dermal exposure, as well as to acquaint Polish users with the principles of the selected model functioning. This paper presents examples of models to assist the employer in the the assessment of occupational exposure associated with the skin contact with chemicals, developed in European Union (EU countries, as well as in countries outside the EU. Based on the literature data dermal exposure models EASE (Estimation and Assessment of Substance Exposure, COSHH Essentials (Control of Substances Hazardous to Health Regulations, DREAM (Dermal Exposure Assessment Method, Stoffenmanager , ECETOC TRA (European Centre for Ecotoxicology and Toxicology of Chemicals Targeted Risk Assessment, MEASE (Metal’s EASE, PHED (Pesticide Handlers Exposure Database, DERM (Dermal Exposure Ranking Method and RISKOFDERM (Risk Assessment of Occupational Dermal Exposure to Chemicals were briefly described. Moreover the characteristics of RISKOFDERM, guidelines for its use, information on input and output data were further detailed. Problem of full work shift dermal exposure assessment is described. An example of exposure assessment using RISKOFDERM and effectiveness evaluation to date were also presented. When no measurements are available, RISKOFDERM allows dermal exposure assessment and thus can improve the risk assessment quality and effectiveness of dermal risk management. Med Pr 2017;68(4:557–569

  11. CTRP6 inhibits fibrogenesis in TGF-β1-stimulated human dermal fibroblasts

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Rong-hui, E-mail: fan_ronghuixa@163.com [Department of Burn and Plastic Surgery, Shaanxi Provincial People’s Hospital, Xi’an 710068 (China); Zhu, Xiu-mei; Sun, Yao-wen [Department of Burn and Plastic Surgery, Shaanxi Provincial People’s Hospital, Xi’an 710068 (China); Peng, Hui-zi [Department of Cosmetology Plastic Surgery, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an, Shaanxi 710061 (China); Wu, Hang-li; Gao, Wen-jie [Department of Burn and Plastic Surgery, Shaanxi Provincial People’s Hospital, Xi’an 710068 (China)

    2016-07-08

    Skin fibrosis is characterized by excessive proliferation of fibroblasts and overproduction of extracellular matrix (ECM). C1q/tumor necrosis factor-related protein 6 (CTRP6), a member of CTRPs, has been involved in the development of cardiac fibrosis. However, the function and detailed regulatory mechanism of CTRP6 in skin fibrosis remain unclear. The aim of this study was to investigate the effect of CTRP6 on the activation of human dermal fibroblasts. Our results showed that CTRP6 was lowly expressed in scar tissues and transforming growth factor-β1 (TGF-β1)-treated dermal fibroblasts. CTRP6 overexpression significantly inhibited the proliferation of dermal fibroblasts, as well as suppressed the expression of ECM in TGF-β1-treated dermal fibroblasts. Furthermore, CTRP6 overexpression markedly inhibited TGF-β1-induced phosphorylation of Smad3 in dermal fibroblasts. In conclusion, the data reported here demonstrate that CTRP6 is able to inhibit the proliferation and ECM expression in human dermal fibroblasts through suppressing the TGF-β1/Smad3 signaling pathway. These findings suggest that CTRP6 may be a potential therapeutic target for the prevention of skin fibrosis. -- Highlights: •CTRP6 expression was decreased in scar tissues and TGF-β1-treated dermal fibroblasts. •CTRP6 inhibits TGF-β1-induced the proliferation of dermal fibroblasts. •CTRP6 inhibits expression of collagen type I and α-SMA. •CTRP6 inhibits the activation of TGF-β1/Smad3 signaling pathway in dermal fibroblasts.

  12. Post-kala-azar dermal leishmaniasis associated with AIDS

    Directory of Open Access Journals (Sweden)

    Bittencourt Achiléa

    2002-01-01

    Full Text Available Post-kala-azar dermal leishmaniasis (PKDL is rarely reported in South America. In spite of the fact that there are many reports about the association of visceral leishmaniasis and AIDS, PKDL is very uncommon in HIV-positive patients, and so far only four cases have been documented in the literature. We present another case with unusual clinicopathological aspects. The patient, a 28-year-old male, from Salvador, Bahia (an endemic area presented with clinical manifestations of visceral leishmaniasis three years after the diagnosis of AIDS. During treatment for visceral leishmaniasis he developed disseminated miliary papules. Microscopically, the skin biopsy showed a "saw-tooth" pattern with a lichenoid mononuclear infiltrate simulating lichen planus. The histopathological diagnosis was achieved through the finding of amastigotes. The authors discuss the clinicopathological aspects of this case based on a review of the specific literature.

  13. Dermal tumorigen PAH and complex mixtures for biological research

    International Nuclear Information System (INIS)

    Griest, W.H.; Guerin, M.R.; Ho, C.

    1985-01-01

    Thirteen commercially available, commonly reported four-five ring dermal tumorigen PAHs, were determined in a set of complex mixtures consisting of crude and upgraded coal liquids, and petroleum crude oils and their distillate fractions. Semi-preparative scale, normal phase high performance liquid chromatographic fractionation followed by capillary column gas chromatography or gas chromatography-mass spectroscopy were used for the measurements. Deuterated or carbon-14 labeled PAH served as internal standards or allowed recovery corrections. Approaches for the preparation and measurement of radiolabeled PAH were examined to provide chemical probes for biological study. Synthetic routes for production of 14 C labeled dihydrobenzo[a]pyrene and 14 C- or 3 H 10-azabenzo[a]pyrene are being studied to provide tracers for fundamental studies in tracheal transplant and skin penetration systems. (DT)

  14. Dermal Titanium Dioxide Deposition Associated With Intralesional Triamcinolone Injection.

    Science.gov (United States)

    Cohen, Brandon E; Bashey, Sameer; Cole, Christine; Abraham, Jerrold L; Ragsdale, Bruce; Ngo, Binh

    2016-12-01

    Cutaneous discoloration secondary to dermal deposition of titanium dioxide (TiO2) particles is recognized but seldom reported in the literature. In this report, the authors describe the case of a 61-year-old gentleman, with a long history of alopecia areata, who presented with numerous, discrete dark blue macules on the scalp. Scanning electron microscopy with energy dispersive x-ray spectroscopy analysis ultimately identified the macules as deposits of TiO2. The patient had a history of intralesional triamcinolone injections for management of alopecia areata. A sample of generic 0.1% triamcinolone acetonide paste was analyzed and found to contain many TiO2 particles analogous to those seen in the patient's biopsy sample. To the authors' knowledge, this is the first reported case of TiO2 deposition in the dermis likely resulting from topical combined with intralesional triamcinolone injection.

  15. Dermal Uptake of Organic Vapors Commonly Found in Indoor Air

    DEFF Research Database (Denmark)

    Weschler, Charles J.; Nazaroff, William W

    2014-01-01

    Transdermal uptake directly from air is a potentially important yet largely overlooked pathway for human exposure to organic vapors indoors. We recently reported (Indoor Air 2012, 22, 356) that transdermal uptake directly from air could be comparable to or larger than intake via inhalation for many......, formaldehyde, and acrolein. Analysis of published experimental data for human subjects for twenty different organic compounds substantiates these model predictions. However, transdermal uptake rates from air have not been measured for the indoor organics that have the largest modeled ratios of dermal......-to-inhalation uptake; for such compounds, the estimates reported here require experimental verification. In accounting for total exposure to indoor organic pollutants and in assessing potential health consequences of such exposures, it is important to consider direct transdermal absorption from air....

  16. Post-kala-azar dermal leishmaniasis associated with AIDS

    Directory of Open Access Journals (Sweden)

    Bittencourt Achiléa

    2003-01-01

    Full Text Available Post-kala-azar dermal leishmaniasis (PKDL is rarely reported in South America. In spite of the fact that there are many reports about the association of visceral leishmaniasis and AIDS, PKDL is very uncommon in HIV-positive patients, and so far only four cases have been documented in the literature. We present another case with unusual clinicopathological aspects. The patient, a 28-year-old male, from Salvador, Bahia (an endemic area presented with clinical manifestations of visceral leishmaniasis three years after the diagnosis of AIDS. During treatment for visceral leishmaniasis he developed disseminated miliary papules. Microscopically, the skin biopsy showed a "saw-tooth" pattern with a lichenoid mononuclear infiltrate simulating lichen planus. The histopathological diagnosis was achieved through the finding of amastigotes. The authors discuss the clinicopathological aspects of this case based on a review of the specific literature.

  17. Microporous dermal-like electrospun scaffolds promote accelerated skin regeneration.

    Science.gov (United States)

    Bonvallet, Paul P; Culpepper, Bonnie K; Bain, Jennifer L; Schultz, Matthew J; Thomas, Steven J; Bellis, Susan L

    2014-09-01

    The goal of this study was to synthesize skin substitutes that blend native extracellular matrix (ECM) molecules with synthetic polymers which have favorable mechanical properties. To this end, scaffolds were electrospun from collagen I (col) and poly(ɛ-caprolactone) (PCL), and then pores were introduced mechanically to promote fibroblast infiltration, and subsequent filling of the pores with ECM. A 70:30 col/PCL ratio was determined to provide optimal support for dermal fibroblast growth, and a pore diameter, 160 μm, was identified that enabled fibroblasts to infiltrate and fill pores with native matrix molecules, including fibronectin and collagen I. Mechanical testing of 70:30 col/PCL scaffolds with 160 μm pores revealed a tensile strength of 1.4 MPa, and the scaffolds also exhibited a low rate of contraction (pores. Keratinocytes formed a stratified layer on the surface of fibroblast-remodeled scaffolds, and staining for cytokeratin 10 revealed terminally differentiated keratinocytes at the apical surface. When implanted, 70:30 col/PCL scaffolds degraded within 3-4 weeks, an optimal time frame for degradation in vivo. Finally, 70:30 col/PCL scaffolds with or without 160 μm pores were implanted into full-thickness critical-sized skin defects. Relative to nonporous scaffolds or sham wounds, scaffolds with 160 μm pores induced accelerated wound closure, and stimulated regeneration of healthy dermal tissue, evidenced by a more normal-appearing matrix architecture, blood vessel in-growth, and hair follicle development. Collectively, these results suggest that microporous electrospun scaffolds are effective substrates for skin regeneration.

  18. The development of argon arc brazing with Cu-based filler for ITER thermal anchor attachment

    International Nuclear Information System (INIS)

    Sun Zhenchao; Li Pengyuan; Pan Chuanjie; Hou Binglin; Han Shilei; Pei Yinyin; Long Weimin

    2012-01-01

    Thermal anchor is the key component of ITER magnet supports to maintain the low temperature for the nor mal operation of superconducting coils. During the advanced research of ITER thermal anchor attachment, dozens of brazing filler and several kinds of brazing technique have been developed and investigated. The test result shows that Cu-based alloy have the preferable mechanical properties at both room temperature and liquid nitrogen temperatures (77 K) for high brazing temperature. And it has a good weldability to 316LN. The brazing temperature of Cu-based filler is over 1000℃, but heat input is relatively low for shallower heating depth of argon arc brazing. Lower heat input is good for the control of brazing deformation. It is no need to clean after brazing because for argon arc brazing there is no bra- zing flux used. Arc brazing with Cu-based filler was chosen as the principal method for the attachment of thermal anchor. (authors)

  19. The Classification and Prognosis of Periocular Complications Related to Blindness following Cosmetic Filler Injection.

    Science.gov (United States)

    Myung, Yujin; Yim, Sangjun; Jeong, Jae Hoon; Kim, Baek-Kyu; Heo, Chan-Yeong; Baek, Rong-Min; Pak, Chang-Sik

    2017-07-01

    Common side effects during hyaluronic acid filler injections are typically mild and reversible, but several reports of blindness have received attention. The present study focused on orbital symptoms combined with blindness, aiming to classify affected patients and predict their disease course and prognosis. From September of 2012 to August of 2015, nine patients with vision loss after filler injection were retrospectively reviewed. Ptosis, ophthalmoplegia, and enophthalmos were recorded over a 6-month follow-up, and patients were classified into four types according to periocular symptom manifestation. Two patients were categorized as type I (blindness without ptosis or ophthalmoplegia), two patients as type II (blindness and ptosis without ophthalmoplegia), two patients as type III (blindness and ophthalmoplegia without ptosis), and three patients as type IV (blindness with ptosis and ophthalmoplegia). The present study includes previously unpublished information about orbital symptom manifestations and prognosis combined with blindness caused by retinal artery occlusion after cosmetic filler injection. Therapeutic, V.

  20. The Effect of Particle Size of Wollastonite Filler on Thermal Performance of Intumescent Fire Retardant Coating

    Directory of Open Access Journals (Sweden)

    Zia-ul-Mustafa M.

    2014-07-01

    Full Text Available Intumescent Fire retardant coatings (IFRC’s are one of the simplest ways to protect substrates exposed to fire. In this study, Wollastonite (W filler of two different particle sizes were used to determine the fire performance of intumescent fire retardant coating. The basic ingredients of the coating were ammonium poly-phosphate (APP as acid source, expandable graphite (EG as carbon source, melamine (MEL as blowing agent in epoxy binder, boric acid as additive and hardener as curing agent. A series of coating formulations were developed by using different weight percentages of both sized Wollastonite fillers. The coated steel substrate samples were tested for fire performance using Bunsen burner and char expansion was measured using furnace fire test. A Comparison of the coatings thermal performance was determined. Wollastonite containing filler particle size 10 μm showed better thermal performance than formulations containing filler’s particle size 44 μm.

  1. Interactive effects between carbon allotrope fillers on the mechanical reinforcement of polyisoprene based nanocomposites

    Directory of Open Access Journals (Sweden)

    M. Galimberti

    2014-06-01

    Full Text Available Interactive effects of carbon allotropes on the mechanical reinforcement of polymer nanocomposites were investigated. Carbon nanotubes (CNT and nano-graphite with high shape anisotropy (nanoG were melt blended with poly(1,4-cis-isoprene, as the only fillers or in combination with carbon black (CB, measuring the shear modulus at low strain amplitudes for peroxide crosslinked composites. The nanofiller was found to increase the low amplitude storage modulus of the matrix, with or without CB, by a factor depending on nanofiller type and content. This factor, fingerprint of the nanofiller, was higher for CNT than for nanoG. The filler-polymer interfacial area was able to correlate modulus data of composites with CNT, CB and with the hybrid filler system, leading to the construction of a common master curve.

  2. High-temperature performance of a new nickel-based filler metal for power generation application

    Energy Technology Data Exchange (ETDEWEB)

    Shingledecker, J.; Coleman, K. [Electric Power Research Institute, Charlotte, NC (United States); Siefert, J.; Tanzosh, J. [Babcok and Wilcox Research Center, Barberton, OH (United States); Newell, W. [Euroweld, Mooresville, NC (United States)

    2010-07-01

    A new nickel-based weld filler metal, EPRI P87, has been developed as a superior alternative to ERNiCr-3 for use in dissimilar metal welds (DMW) between ferritic and austenitic materials. EPRI P87 has a low coefficient of thermal expansion more closely matching alloys such as Grade 91 and 92 than other available filler metals. Additionally, the size of the carbon denuded region adjacent to the weld in the heat-affected-zone is minimized/eliminated by proper control of weld metal composition. In this work the high-temperature mechanical behavior of DMWs utilizing EPRI P87 (GTAW and GMAW processes) was characterized through tensile and long-term creep-rupture testing. Microstructure analysis was also conducted on tested specimens to evaluate the HAZ regions and failure modes. Performance of the weld metal and welded joints is discussed and compared with ERNiCr-3 and typical 9%Cr-MoV filler metals. (orig.)

  3. Comparison between rice husk ash and commercial silica as filler in polymeric composites

    International Nuclear Information System (INIS)

    Fernandes, I.J.; Calheiro, D.; Santos, E.C.A. dos; Oliveira, R.; Rocha, T.L.A.C.; Moraes, C.A.M.

    2014-01-01

    The use of rice husk ash (RHA) as filler in polymeric materials has been studied in different polymers. Research reported that RHA may successfully replace silica. The silica production process using ore demands high energy input and produces considerable amounts of waste. Therefore, the replacement of silica by RHA may be economically and environmentally advantageous, reducing environmental impact and adding value to a waste material. In this context, this study characterizes and compares RHA of different sources (travelling grate reactor and fluidized bed reactor) with commercially available silicas to assess performance as filler in polymeric materials. Samples were characterized by X-ray fluorescence, loss on ignition, X-ray diffraction, grain size, specific surface area and specific weight. The results show that RHA may be used as a filler in several polymeric materials.(author)

  4. Highly ductile UV-shielding polymer composites with boron nitride nanospheres as fillers.

    Science.gov (United States)

    Fu, Yuqiao; Huang, Yan; Meng, Wenjun; Wang, Zifeng; Bando, Yoshio; Golberg, Dmitri; Tang, Chengchun; Zhi, Chunyi

    2015-03-20

    Polymer composites with enhanced mechanical, thermal or optical performance usually suffer from poor ductility induced by confined mobility of polymer chains. Herein, highly ductile UV-shielding polymer composites are successfully fabricated. Boron nitride (BN) materials, with a wide band gap of around ∼6.0 eV, are used as fillers to achieve the remarkably improved UV-shielding performance of a polymer matrix. In addition, it is found that spherical morphology BN as a filler can keep the excellent ductility of the composites. For a comparison, it is demonstrated that traditional fillers, including conventional BN powders can achieve the similar UV-shielding performance but dramatically decrease the composite ductility. The mechanism behind this phenomenon is believed to be lubricant effects of BN nanospheres for sliding of polymer chains, which is in consistent with the thermal analyses. This study provides a new design to fabricate UV-shielding composite films with well-preserved ductility.

  5. Research on the Hydrophilic Modified of LDPE for the New Biological Suspended Filler

    Directory of Open Access Journals (Sweden)

    Kang Weijia

    2016-01-01

    Full Text Available Urban sewage is one of the main pollution sources of the city, which pollute soil, deteriorate the water quality and increase the water shortages and urban load. LDPE is low cost and widely used as the basic material of wastewater treatment, but LDPE’s hydrophilic is not good enough to meet the need of suspended filler in wastewater treatment. In this paper the hydrophilic modified of LDPE for the new biological suspended filler was studied and the preparation and processing technique based on LDPE was researched. The hydrophilic and mechanic performance of the hydrophilic modified materials was tested. Results shown that the new type of hydrophilic modified materials has good hydrophilic and meets the demand of urban sewage treatment. The research on the new suspended filler materials has great meaning in solving the problem of urban sewage and recycling.

  6. Properties of concrete containing coconut shell powder (CSP) as a filler

    Science.gov (United States)

    Leman, A. S.; Shahidan, S.; Nasir, A. J.; Senin, M. S.; Zuki, S. S. Mohd; Ibrahim, M. H. Wan; Deraman, R.; Khalid, F. S.; Azhar, A. T. S.

    2017-11-01

    Coconut shellsare a type of agricultural waste which can be converted into useful material. Therefore,this study was conducted to investigate the properties of concrete which uses coconut shell powder (CSP) filler material and to define the optimum percentage of CSP which can be used asfiller material in concrete. Comparisons have been made between normal concrete mixes andconcrete containing CSP. In this study, CSP was added into concrete mixes invaryingpercentages (0%, 2%, 4%, 6%, 8% and 10%). The coconut shell was grounded into afine powder before use. Experimental tests which have been conducted in this study include theslump test, compressive test and splitting tensile strength test. CSP have the potential to be used as a concrete filler and thus the findings of this study may be applied to the construction industry. The use of CSP as a filler in concrete can help make the earth a more sustainable and greener place to live in.

  7. Quantification of dermal exposure to nanoparticles from solid nanocomposites by using single particle ICP-MS

    DEFF Research Database (Denmark)

    Mackevica, Aiga; Olsson, Mikael Emil; Hansen, Steffen Foss

    2016-01-01

    , optical or photocatalytical properties. There is a lot of research focusing on effects exerted by nanoparticles, but the knowledge concerning release and subsequential exposure to nanoparticles is very limited, and information regarding potential dermal exposure from nanomaterial containing solid articles...... and characterization. In this study, we have investigated the potential dermal exposure to three different types of nano-enabled consumer products: Ag-containing keyboard covers, TiO2 coated ceramic tiles, and wood painted with CuO containing paint. The potential for dermal transfer from the aforementioned surfaces...

  8. Effect Assessment the Impact of Filler Types on the Input Design Parameter of Flexible Pavements

    Directory of Open Access Journals (Sweden)

    Sahar S. Neham

    2017-08-01

    Full Text Available To meet the requirements of flexible pavements (safety, economy, limited the stresses on the natural subgrade and a smooth ride, good quality material of surface course must be used so to prevent pavement distresses caused by the different types of loadings (structural and environmental loadings, while the resilient modulus is important input data when flexible pavement was designed, it is selected to show its effect by different types of mineral filler as a partial replacement. In this paving mix, to improve the quality of the mix material and to represent the effect of these replacements materials on the elastic characterization by measuring the resilient modulus of hot mix asphalt (HMA: Fly Ash (FA, Ordinary Portland Cement (OPC, Hydrated Lime (HL and Silica Fume (SF are used as a partial percent of filler (Limestone Dust (LSD replacement, where these materials are locally available including (40-50 penetration grade asphalt binder. To achieve the goal of study; asphalt concrete mixes are prepared at their optimum asphalt content using Marshall Method of mix design. Four replacement percent’s were used; 0, 1.5, 3.0 and 4.5 percent by total weight of aggregate for each filler types. According to ASTM D4123 criteria (Resilient Modulus was tested by UTM¬25. Mixes modified with (FA, (OPC, (HL and (SF were found to have average improvement in the value of Resilient Modulus by (13.37, 9.63, 11.14, 24.00 % at 1.5 percent of filler replacement and by (24.54, 16.63, 18.73, 38.31 % at 3.0 percent of filler replacement also the percent of improvement is: (39.55, 26.36, 29.82, 58.30 at 4.5percent of filler replacement sequentially.

  9. Use of bottom ash from thermal power plant and lime as filler in bituminous mixtures

    Directory of Open Access Journals (Sweden)

    López-López, E.

    2015-06-01

    Full Text Available This study focuses on the characterization of bottom ash (PCC-BA and determining the mechanical characteristics of hot mix asphalt (HMA using PCC-BA and hydrated lime (HL as filler. Physical and chemical characterization of the bottom ash was carried out to evaluate its eventual reutilization as filler substitute. The materials tested in this study were made using 0%, 25%, 50%, 70% and 100% of PCC-BA combined with HL. HMA mixes were evaluated in terms of their engineering properties, namely: air voids in the mixes, water sensitivity, stiffness modulus, performance in wheel tracking test and fatigue resistance. The results obtained indicate that HMA mixes with a filler blend of 70% PCC-BA and 30% HL fulfil European standards and are suitable for light traffic or small infrastructures.Este estudio se centra en la caracterización de las cenizas de fondo (PCC-BA y la determinación de las características mecánicas de mezclas bituminosas en caliente (HMA, utilizando cenizas de fondo y la cal hidratada (HL como filler. Se realizó la caracterización física y química de las cenizas de fondo para evaluar su empleo como sustituto de filler. Las mezclas ensayadas en este estudio se realizaron utilizando 0%, 25%, 50%, 70% y 100% de cenizas de fondo combinadas con cal hidratada. Se evaluaron propiedades ingenieriles de las mezclas bituminosas, tales como los huecos de aire en las mezclas, la sensibilidad al agua, el módulo de rigidez, el ensayo de pista y la resistencia a la fatiga. Los resultados obtenidos indican que las mezclas bituminosas fabricadas con una combinación de filler del 70% de cenizas de fondo y el 30% cal hidratada, cumplen con las normas europeas y son adecuados para su aplicación con tráficos ligeros o en pequeñas infraestructuras.

  10. Influencia del filler calizo en las propiedades de los morteros a resistencia constante

    Directory of Open Access Journals (Sweden)

    Hernández, Francisco

    1994-03-01

    Full Text Available This article studies the effects produced by the lime filler on the Portugal cement used with additions in the production of mortars. The starting point is a Portland cement to which different ratios of lime filler, ranging from 0-50%, are added. The next step consists of preparing mortar specimens using standardized sand as aggregate, curing them up to the age of 28 days when they are put to flexo-tensile and compression tests. The mortar strength is fixed at the age of 28 days, making it coincide with the strength of a pattern cement mortar (cement without additions of the same age. Then the effects of the filler on the slump and the water cement relation are observed for fixed strength.

    En este artículo se estudian los efectos producidos por el "filler" calizo en el cemento portland al utilizar este cemento con adiciones, en la fabricación de morteros. Se parte de un cemento portland al que se le añaden proporciones de "filler" calizo desde O hasta el 50%, y se preparan probetas de mortero utilizando como árido arena normalizada, curándose a continuación hasta la edad de 28 días, fecha en la que se someten a rotura por flexotracción y compresión. La resistencia de los morteros se fija a la edad de 28 días, haciéndola coincidir con la de un mortero de cemento patrón (cemento sin adiciones a la misma edad, y se observan, a resistencia fija, los efectos del "filler" sobre el escurrimiento y relación agua/cemento.

  11. Hybrid waste filler filled bio-polymer foam composites for sound absorbent materials

    Science.gov (United States)

    Rus, Anika Zafiah M.; Azahari, M. Shafiq M.; Kormin, Shaharuddin; Soon, Leong Bong; Zaliran, M. Taufiq; Ahraz Sadrina M. F., L.

    2017-09-01

    Sound absorption materials are one of the major requirements in many industries with regards to the sound insulation developed should be efficient to reduce sound. This is also important to contribute in economically ways of producing sound absorbing materials which is cheaper and user friendly. Thus, in this research, the sound absorbent properties of bio-polymer foam filled with hybrid fillers of wood dust and waste tire rubber has been investigated. Waste cooking oil from crisp industries was converted into bio-monomer, filled with different proportion ratio of fillers and fabricated into bio-polymer foam composite. Two fabrication methods is applied which is the Close Mold Method (CMM) and Open Mold Method (OMM). A total of four bio-polymer foam composite samples were produce for each method used. The percentage of hybrid fillers; mixture of wood dust and waste tire rubber of 2.5 %, 5.0%, 7.5% and 10% weight to weight ration with bio-monomer. The sound absorption of the bio-polymer foam composites samples were tested by using the impedance tube test according to the ASTM E-1050 and Scanning Electron Microscope to determine the morphology and porosity of the samples. The sound absorption coefficient (α) at different frequency range revealed that the polymer foam of 10.0 % hybrid fillers shows highest α of 0.963. The highest hybrid filler loading contributing to smallest pore sizes but highest interconnected pores. This also revealed that when highly porous material is exposed to incident sound waves, the air molecules at the surface of the material and within the pores of the material are forced to vibrate and loses some of their original energy. This is concluded that the suitability of bio-polymer foam filled with hybrid fillers to be used in acoustic application of automotive components such as dashboards, door panels, cushion and etc.

  12. Development of brazing process for W-EUROFER joints using Cu-based fillers

    Science.gov (United States)

    de Prado, J.; Sánchez, M.; Ureña, A.

    2016-02-01

    A successful joint between W and EUROFER using high temperature brazing technique has been achieved for structural application in future fusion power plants. Cu-based powder alloy mixed with a polymeric binder has been used as filler. Microstructural analysis of the joints revealed that the joint consisted mainly of primary phases and acicular structures in a Cu matrix. Interaction between EUROFER and filler took place at the interface giving rise to several Cu-Ti-Fe rich layers. A loss of hardness at the EUROFER substrate close to the joint due to a diffusion phenomenon during brazing cycle was measured; however, the joints had an adequate shear strength value.

  13. Reactive Diazonium-Modified Silica Fillers for High-Performance Polymers.

    Science.gov (United States)

    Sandomierski, Mariusz; Strzemiecka, Beata; Chehimi, Mohamed M; Voelkel, Adam

    2016-11-08

    We describe a simple way of modification of three silica-based fillers with in situ generated 4-hydroxymethylbenzenediazonium salt ( + N 2 -C 6 H 4 -CH 2 OH). The rationale for using a hydroxyl-functionalized diazonium salt is that it provides surface-functionalized fillers that can react with phenolic resins. The modification of silica by diazonium salts was assessed using Fourier transform infrared (FTIR) spectroscopy and X-ray photoelectron spectroscopy (XPS). FTIR spectroscopy permitted the tracking of benzene ring breathing and C-C. The absence of the characteristic N≡N stretching vibration in the 2200-2300 cm -1 range indicates the loss of the diazonium group. XPS results indicate a higher C/Si atomic ratio after the diazonium modification of fillers and the presence of π-π* C1s satellite peaks characteristic of the surface-tethered aromatic species. Adhesion of aryl layers to the silicas is excellent because they withstand harsh thermal and organic solvent treatments. Phenolic resins (used, for example, as binders in abrasive products) were filled with diazonium-modified silicas at 10-25 wt %. The reactivity of the fillers toward phenolic resins was evaluated by the determination of the flow distance. After annealing at 180 °C, the diazonium-modified silica/phenolic resin composites were mechanically tested using the three-point flexural method. The flexural strength was found to be up to 35% higher than that of the composites prepared without any diazonium salts. Diazonium-modified silica with surface-bound -CH 2 -OH groups is thus ideal reactive filler for phenolic resins. Such filler ensures interfacial chemical reactions with the matrix and imparts robust mechanical properties to the final composites. This specialty diazonium-modified silica will find potential application as fillers in the composites for the abrasive industry. More generally, aryl diazonium salts are a unique new series of compounds for tailoring the surface properties of fillers

  14. Brazing Inconel 625 Using Two Ni/(Fe)-Based Amorphous Filler Foils

    Science.gov (United States)

    Chen, Wen-Shiang; Shiue, Ren-Kae

    2012-07-01

    For MBF-51 filler, the brazed joint consists of interfacial grain boundary borides, coarse Nb6Ni16Si7, and Ni/Cr-rich matrix. In contrast, the VZ-2106 brazed joint is composed of interfacial Nb6Ni16Si7 precipitates as well as grain boundary borides, coarse Nb6Ni16Si7, and Ni/Cr/Fe-rich matrix. The maximum tensile strength of 443 MPa is obtained from the MBF-51 brazed specimen. The tensile strengths of VZ-2106 brazed joints are approximately 300 MPa. Both amorphous filler foils demonstrate potential in brazing IN-625 substrate.

  15. Buffing dust as a filler of carboxylated butadiene-acrylonitrile rubber and butadiene-acrylonitrile rubber.

    Science.gov (United States)

    Chronska, K; Przepiorkowska, A

    2008-03-01

    Buffing dust from chrome tanned leather is one of the difficult tannery wastes to manage. It is also hazardous to both human health and the environment. The scientific literature rarely reports studies on dust management, especially on its utilization as a filler for elastomers. In this connection we have made an attempt to use this leather waste as a filler for rubbers such as XNBR and NBR. The addition of the buffing dust to rubber mixes brought improvement in mechanical properties, and increase in resistance to thermal ageing as well as in electric conductivity and crosslink density of vulcalizates.

  16. Numerical simulation of TIG welding with filler of steel pieces of high thickness

    International Nuclear Information System (INIS)

    Carmignani, B.; Toselli, G.

    1999-01-01

    The problem of the numerical simulation of welding process with filler, in particular TIG (tungsten inert gas) with cold filler, has been approached with ABAQUS/S code. Reference has been made to some experimental models studied and prepared ad hoc in order to better know the physical phenomena involved in the TIG welding technique and to validate the computation methodologies and results obtained. This numerical simulation has been required in order to assist the fabrication development and QA for TF (toroidal field) coil case, an important component of ITER (international thermonuclear experimental reactor) machine [it

  17. Effects of trace fillers on the radiation-induced crosslinking of polyethylene

    International Nuclear Information System (INIS)

    Chappas, W.J.; Silverman, J.

    1979-01-01

    Silica-filled samples of low-density polyethylene were subjected to γ and electron irradiation. The insoluble fraction determined by Soxhlet extraction was found to be independent of filler concentrations up to 0.5% by volume. The results show no evidence to support the previously reported work by Gordiyenko et al. of a sharp increase in the gel fraction of irradiated samples with filler concentrations of 0.2%. Substantial changes in the conditions of irradiation and of sample preparation and treatment do not affect gel yields strongly

  18. Comparative assessment of filler wires for argon-arc welding of refractory alloys

    International Nuclear Information System (INIS)

    Sorokin, L.I.; Bagdasarov, Yu.S.; Tupikin, V.I.

    1993-01-01

    It is recommended to use wires of similar composition as filler material during argon-arc welding of heat resisting alloys, and Sv-08Kh20N57M8V8T3R wire - for welding of dispersion hardening alloys. Sv-06Kh15N60M15, Sv-KhN64KBMYuVF or Kh11N60M23 wires should be used as filler materials to decrease tendency of welded joints to cracking during welding and heat treatment

  19. Assessment of the Resistance to External Factors of Low-Density Polyethylene Modified with Natural Fillers

    Directory of Open Access Journals (Sweden)

    Karolina Głogowska

    2017-12-01

    Full Text Available The study reports the results of investigation of basic processing and thermal properties of low-density polyethylene modified with two types of natural filler: wheat bran and pumpkin seed hulls, their content ranging from 5% to 15% relative to the matrix. In addition, the physical properties of the produced granulates are determined, i.e. the relationship between their density and the applied contents of the tested fillers. Furthermore, the study reports the results concerning the longitudinal shrinkage, abrasion resistance and cold water absorption of injection molded tensile specimens.

  20. Characterization of electron-beam-modified surface coated clay fillers and their influence on physical properties of rubbers

    International Nuclear Information System (INIS)

    Ray, Sudip; Bhowmick, Anil K.; Sarma, K.S.S.; Majali, A.B.; Tikku, V.K.

    2002-01-01

    A novel process of surface modification of clay filler has been developed by coating this with an acrylate monomer, trimethylol propane triacrylate (TMPTA) or a silane coupling agent, triethoxy vinyl silane (TEVS) followed by electron beam irradiation. Characterization of these surface modified fillers has been carried out by Fourier-transform infrared analysis (FTIR), electron spectroscopy for chemical analysis (ESCA), wettability by dynamic wicking method measuring the rise of a liquid through a filler-packed capillary tube and water flotation test, scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), thermogravimetric analysis (TGA), and X-ray diffraction (XRD). Presence of the acrylate and the silane coupling agent on the modified fillers has been confirmed from FTIR, ESCA, and EDX studies, which has also been supported by TGA studies. The contact angle measurement by dynamic wicking method suggests improvement in hydrophobicity of the treated fillers, which is supported by water flotation test especially in the case of silanized clay. However, XRD studies demonstrate that the entire modification process does not affect the bulk properties of the fillers. Finally, both unmodified and modified clay fillers have been incorporated in styrene butadiene rubber (SBR) and nitrile rubber (NBR). Rheometric and mechanical properties reveal that there is a definite improvement using these modified fillers specially in the case of silanized clay compared to the control sample, probably due to successful enhancement in interaction between the treated clay and the base polymer

  1. Characterization of electron-beam-modified surface coated clay fillers and their influence on physical properties of rubbers

    Science.gov (United States)

    Ray, Sudip; Bhowmick, Anil K.; Sarma, K. S. S.; Majali, A. B.; Tikku, V. K.

    2002-12-01

    A novel process of surface modification of clay filler has been developed by coating this with an acrylate monomer, trimethylol propane triacrylate (TMPTA) or a silane coupling agent, triethoxy vinyl silane (TEVS) followed by electron beam irradiation. Characterization of these surface modified fillers has been carried out by Fourier-transform infrared analysis (FTIR), electron spectroscopy for chemical analysis (ESCA), wettability by dynamic wicking method measuring the rise of a liquid through a filler-packed capillary tube and water flotation test, scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), thermogravimetric analysis (TGA), and X-ray diffraction (XRD). Presence of the acrylate and the silane coupling agent on the modified fillers has been confirmed from FTIR, ESCA, and EDX studies, which has also been supported by TGA studies. The contact angle measurement by dynamic wicking method suggests improvement in hydrophobicity of the treated fillers, which is supported by water flotation test especially in the case of silanized clay. However, XRD studies demonstrate that the entire modification process does not affect the bulk properties of the fillers. Finally, both unmodified and modified clay fillers have been incorporated in styrene butadiene rubber (SBR) and nitrile rubber (NBR). Rheometric and mechanical properties reveal that there is a definite improvement using these modified fillers specially in the case of silanized clay compared to the control sample, probably due to successful enhancement in interaction between the treated clay and the base polymer.

  2. Long-term performance of thermoplastic composite material with cotton burr and stem (CBS) as a partial filler

    Science.gov (United States)

    Rationale: Cotton burr and stem (CBS) fraction of cotton gin byproducts has shown promise as a fiber filler in thermoplastic composites, with physical and mechanical properties comparable to that made with wood fiber fillers. However, the long-term performance of this composite material is not known...

  3. Novel phthalocyanine crystals as a conductive filler in crosslinked epoxy materials: Fractal particle networks and low percolation thresholds

    NARCIS (Netherlands)

    Chen, Zhe; Brokken-Zijp, J.C.M.; Michels, M.A.J.

    2006-01-01

    Novel nanosized crystals of aquocyanophthalocyaninatocobalt (III) (Phthalcon 11) were used as a conductive filler in crosslinked epoxy materials. The crosslinked composite materials had a very low percolation threshold (c 0.9 vol %). The relationship between the volume conductivity and the filler

  4. Effect on mechanical properties of glass reinforced epoxy (GRE) pipe filled with different geopolymer filler molarity for piping application

    Science.gov (United States)

    Hashim, M. F. Abu; Abdullah, M. M. A.; Ghazali, C. M. R.; Hussin, K.; Binhussain, M.

    2017-04-01

    This study investigated the use of a novel white clay geopolymer as a filler to produce high strength glass reinforced epoxy pipe. It was found that using white clay geopolymer as filler gives better compressive strength to the glass reinforced epoxy pipe. The disadvantages of current glass reinforced epoxy pipes such low compressive strength which can be replaced by the composite pipes. Geopolymerization is an innovative technology that can transform several aluminosilicate materials into useful products called geopolymers or inorganic polymers. A series of glass reinforced epoxy pipe and glass reinforced epoxy pipe filled with 10 - 40 weight percentages white clay geopolymer filler with 4 Molarity and 8 Molarity were prepared. Morphology of white clay geopolymer filler surface was indicates using scanning electron microscopy. The additions of white clay geopolymer filler for both 4 Molarity and 8 Molarity show higher compressive strength than glass reinforced epoxy pipe without any geopolymer filler. The compressive test of these epoxy geopolymer pipe samples was determined using Instron Universal Testing under compression mode. Nonetheless, the compressive strength of glass reinforced epoxy pipe with white clay geopolymer filler continues to drop when added to 40 wt% of the geopolymer filler loading for both 4 Molarity and 8 Molarity. These outcomes showed that the mixing of geopolymer materials in epoxy system can be attained in this research.

  5. Method and apparatus for welding workpieces along a seam with the aid of a filler material deposited in the seam

    International Nuclear Information System (INIS)

    1979-01-01

    A method and apparatus for welding a nuclear reactor core barrel in a very precise and controlled manner is given. The power employed to preheat the filler material at its operating level is automatically controlled as a continuous non-linear function of the filler feed speed. (UK)

  6. Functional trade-off between strength and thermal capacity of dermal armor: Insights from girdled lizards.

    Science.gov (United States)

    Broeckhoven, Chris; du Plessis, Anton; Hui, Cang

    2017-10-01

    The presence of dermal armor is often unambiguously considered the result of an evolutionary predator-prey arms-race. Recent studies focusing predominantly on osteoderms - mineralized elements embedded in the dermis layer of various extant and extinct vertebrates - have instead proposed that dermal armor might exhibit additional functionalities besides protection. Multiple divergent functionalities could impose conflicting demands on a phenotype, yet, functional trade-offs in dermal armor have rarely been investigated. Here, we use high-resolution micro-computed tomography and voxel-based simulations to test for a trade-off between the strength and thermal capacity of osteoderms using two armored cordylid lizards as model organisms. We demonstrate that high vascularization, associated with improved thermal capacity might limit the strength of osteoderms. These results call for a holistic, cautionary future approach to studies investigating dermal armor, especially those aiming to inspire artificial protective materials. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. A Fibrocontractive Mechanochemical Model of Dermal Wound Closure Incorporating Realistic Growth Factor Kinetics

    KAUST Repository

    Murphy, Kelly E.

    2012-01-13

    Fibroblasts and their activated phenotype, myofibroblasts, are the primary cell types involved in the contraction associated with dermal wound healing. Recent experimental evidence indicates that the transformation from fibroblasts to myofibroblasts involves two distinct processes: The cells are stimulated to change phenotype by the combined actions of transforming growth factor β (TGFβ) and mechanical tension. This observation indicates a need for a detailed exploration of the effect of the strong interactions between the mechanical changes and growth factors in dermal wound healing. We review the experimental findings in detail and develop a model of dermal wound healing that incorporates these phenomena. Our model includes the interactions between TGFβ and collagenase, providing a more biologically realistic form for the growth factor kinetics than those included in previous mechanochemical descriptions. A comparison is made between the model predictions and experimental data on human dermal wound healing and all the essential features are well matched. © 2012 Society for Mathematical Biology.

  8. Osteopathia striata: a characteristic X-ray finding in focal dermal hypoplasia (Goltz-Gorlin syndrome)

    Energy Technology Data Exchange (ETDEWEB)

    Barthels, W.; Boepple, D.; Petzel, H.

    1982-12-01

    Two cases of the very rare Goltz-Gorlin syndrome are presented. The relationship of osteopathia striata and focal dermal hypoplasia is discussed, and it is concluded that the osteopathia striata represents the characteristic picture of this ectopic mesodermal abnormality.

  9. In vitro dermal absorption of decabromodiphenyl ethane in rat and human skin

    Data.gov (United States)

    U.S. Environmental Protection Agency — In vitro dermal absorption of decabromodiphenyl ethane in rat and human skin. This dataset is associated with the following publication: Knudsen, G., J.M. Sanders,...

  10. Reliability of a semi-quantitative method for dermal exposure assessment (DREAM)

    NARCIS (Netherlands)

    Wendel de Joode, B. van; Hemmen, J.J. van; Meijster, T.; Major, V.; London, L.; Kromhout, H.

    2005-01-01

    Valid and reliable semi-quantitative dermal exposure assessment methods for epidemiological research and for occupational hygiene practice, applicable for different chemical agents, are practically nonexistent. The aim of this study was to assess the reliability of a recently developed

  11. A Fibrocontractive Mechanochemical Model of Dermal Wound Closure Incorporating Realistic Growth Factor Kinetics

    KAUST Repository

    Murphy, Kelly E.; Hall, Cameron L.; Maini, Philip K.; McCue, Scott W.; McElwain, D. L. Sean

    2012-01-01

    Fibroblasts and their activated phenotype, myofibroblasts, are the primary cell types involved in the contraction associated with dermal wound healing. Recent experimental evidence indicates that the transformation from fibroblasts to myofibroblasts involves two distinct processes: The cells are stimulated to change phenotype by the combined actions of transforming growth factor β (TGFβ) and mechanical tension. This observation indicates a need for a detailed exploration of the effect of the strong interactions between the mechanical changes and growth factors in dermal wound healing. We review the experimental findings in detail and develop a model of dermal wound healing that incorporates these phenomena. Our model includes the interactions between TGFβ and collagenase, providing a more biologically realistic form for the growth factor kinetics than those included in previous mechanochemical descriptions. A comparison is made between the model predictions and experimental data on human dermal wound healing and all the essential features are well matched. © 2012 Society for Mathematical Biology.

  12. In vitro bioaccessibility of copper azole following simulated dermal transfer from pressure-treated wood

    Data.gov (United States)

    U.S. Environmental Protection Agency — In vitro bioaccessibility of copper azole following simulated dermal transfer from pressure-treated wood. This dataset is associated with the following publication:...

  13. Advective and diffusive dermal processes for estimating terrestrial amphibian pesticide exposure

    Science.gov (United States)

    Background/Question/Methods Dermal exposure presents a potentially significant but understudied route for pesticide uptake in terrestrial amphibians. Historically, evaluation of pesticide risk to both amphibians and reptiles has been achieved by comparing ingestion and inhalat...

  14. Increased dermal mast cell prevalence and susceptibility to development of basal cell carcinoma in humans

    DEFF Research Database (Denmark)

    Grimbaldeston, Michele A; Skov, Lone; Finlay-Jones, John J

    2002-01-01

    eliminate them. Studies in a range of inbred mouse strains as well as mast cell-depleted mice reconstituted with mast cell precursors support a functional link between histamine-staining dermal mast cells and the extent of susceptibility to UVB-induced systemic immunomodulation. Humans, like mouse strains......, display variations in dermal mast cell prevalence. In a study of Danish and South Australian BCC patients and control subjects, one 4-mm punch biopsy of non-sun-exposed buttock skin was sampled from each participant. This skin site was investigated to avoid any changes in mast cell prevalence caused...... by sun exposure. Two sections (4 microm) per biopsy were immunohistochemically stained for detection of histamine-containing dermal mast cells. Computer-generated image analysis evaluated dermal mast cell prevalence in both sections by quantifying the total number of mast cells according to the total...

  15. Quick Maintenance for High Voltage Equipment with the New Not Toxic Boron Nitride Powder (BN100) Superior Thermal Conductive and Lightweight Filler

    National Research Council Canada - National Science Library

    Boer, Fabrizio

    2005-01-01

    .... The BN100 superior thermal conductive and lightweight filler technology is a new filler technology, that not only lets Users a full access for maintenance because cure-free being compounded by loose...

  16. Regeneration of dermal patterns from the remaining pigments after surgery in Eublepharis macularius (a case report)

    OpenAIRE

    Nakashima, Noriyuki

    2016-01-01

    Background: Dermal injury of the Eublepharis macularius (leopard gecko) often results in a loss of the spotted patterns. The scar is usually well recovered, but the spots and the tubercles may be lost depending on the size and part of the lesion. This report presents a surgical attempting, in which the pigments in the edge of the remaining skin flap are partially preserved to maximally restore the natural pigmentation patterns during the course of dermal regeneration. Case presentation: A fou...

  17. Characterization and evolution of dermal filaments from patients with Morgellons disease

    OpenAIRE

    Middelveen, Marianne J; Mayne, Peter J; Kahn, Douglas G; Stricker, Raphael B

    2013-01-01

    Marianne J Middelveen,1 Peter J Mayne,1 Douglas G Kahn,2 Raphael B Stricker11International Lyme and Associated Diseases Society, Bethesda, MD, USA; 2Department of Pathology, Olive View–UCLA Medical Center, Sylmar, CA, USAAbstract: Morgellons disease is an emerging skin disease characterized by formation of dermal filaments associated with multisystemic symptoms and tick-borne illness. Some clinicians hypothesize that these often colorful dermal filaments are textile fibers, either s...

  18. Chest wall reconstruction with acellular dermal matrix (Strattice™) and a TRAM flap

    DEFF Research Database (Denmark)

    Brunbjerg, Mette Eline; Juhl, Alexander Andersen; Damsgaard, Tine Engberg

    2014-01-01

    Mette Eline Brunbjerg, Alexander Andersen Juhl, Tine E. Damsgaard. "Chest wall reconstruction with acellular dermal matrix (Strattice™) and a TRAM flap.” Acta Oncol. 2013 Jun;52(5):1052-4. Epub 2012 Oct 24. PMID: 23095144......Mette Eline Brunbjerg, Alexander Andersen Juhl, Tine E. Damsgaard. "Chest wall reconstruction with acellular dermal matrix (Strattice™) and a TRAM flap.” Acta Oncol. 2013 Jun;52(5):1052-4. Epub 2012 Oct 24. PMID: 23095144...

  19. Collagen/chitosan based two-compartment and bi-functional dermal scaffolds for skin regeneration

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Feng [Department of Plastic Surgery and Burns, Shenzhen Second People' s Hospital, Shenzhen 518035 (China); Wang, Mingbo [Key Laboratory of Biomedical Materials and Implants, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518057 (China); She, Zhending [Key Laboratory of Biomedical Materials and Implants, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518057 (China); Shenzhen Lando Biomaterials Co., Ltd., Shenzhen 518057 (China); Fan, Kunwu; Xu, Cheng [Department of Plastic Surgery and Burns, Shenzhen Second People' s Hospital, Shenzhen 518035 (China); Chu, Bin; Chen, Changsheng [Key Laboratory of Biomedical Materials and Implants, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518057 (China); Shi, Shengjun, E-mail: shengjunshi@yahoo.com [The Burns Department of Zhujiang Hospital, Southern Medical University, Guangzhou 510280 (China); Tan, Rongwei, E-mail: tanrw@landobiom.com [Key Laboratory of Biomedical Materials and Implants, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518057 (China); Shenzhen Lando Biomaterials Co., Ltd., Shenzhen 518057 (China)

    2015-07-01

    Inspired from the sophisticated bilayer structures of natural dermis, here, we reported collagen/chitosan based two-compartment and bi-functional dermal scaffolds. Two functions refer to mediating rapid angiogenesis based on recombinant human vascular endothelial growth factor (rhVEGF) and antibacterial from gentamicin, which were encapsulated in PLGA microspheres. The gentamicin and rhVEGF encapsulated PLGA microspheres were further combined with collagen/chitosan mixtures in low (lower layer) and high (upper layer) concentrations, and molded to generate the two-compartment and bi-functional scaffolds. Based on morphology and pore structure analyses, it was found that the scaffold has a distinct double layered porous and connective structure with PLGA microspheres encapsulated. Statistical analysis indicated that the pores in the upper layer and in the lower layer have great variations in diameter, indicative of a two-compartment structure. The release profiles of gentamicin and rhVEGF exceeded 28 and 49 days, respectively. In vitro culture of mouse fibroblasts showed that the scaffold can facilitate cell adhesion and proliferation. Moreover, the scaffold can obviously inhibit proliferation of Staphylococcus aureus and Serratia marcescens, exhibiting its unique antibacterial effect. The two-compartment and bi-functional dermal scaffolds can be a promising candidate for skin regeneration. - Highlights: • The dermal scaffold is inspired from the bilayer structures of natural dermis. • The dermal scaffold has two-compartment structures. • The dermal scaffold containing VEGF and gentamicin encapsulated PLGA microspheres • The dermal scaffold can facilitate cell adhesion and proliferation.

  20. Sexual dimorphisms in the dermal denticles of the lesser-spotted catshark, Scyliorhinus canicula (Linnaeus, 1758.

    Directory of Open Access Journals (Sweden)

    Neil Crooks

    Full Text Available The dermal layers of several elasmobranch species have been shown to be sexually dimorphic. Generally, when this occurs the females have thicker dermal layers compared to those of males. This sexual dimorphism has been suggested to occur as a response to male biting during mating. Although male biting as a copulatory behaviour in Scyliorhinus canicula has been widely speculated to occur, only relatively recently has this behaviour been observed. Male S. canicula use their mouths to bite the female's pectoral and caudal fins as part of their pre-copulatory behaviour and to grasp females during copulation. Previous work has shown that female S. canicula have a thicker epidermis compared to that of males. The structure of the dermal denticles in females may also differ from that of males in order to protect against male biting or to provide a greater degree of friction in order to allow the male more purchase. This study reveals that the length, width and density of the dermal denticles of mature male and female S. canicula are sexually dimorphic across the integument in areas where males have been observed to bite and wrap themselves around females (pectoral fin, area posterior to the pectoral fin, caudal fin, and pelvic girdle. No significant differences in the dermal denticle dimensions were found in other body areas examined (head, dorsal skin and caudal peduncle. Sexually dimorphic dermal denticles in mature S. canicula could be a response to male biting/wrapping as part of the copulatory process.

  1. Dermal changes in superficial basal cell carcinoma, melanoma in situ and actinic keratosis and their implications

    Science.gov (United States)

    Kazlouskaya, Viktoryia; Malhotra, Saurabh; Navarro, Raquel; Wu, Karen Nguyen; Shvartsbeyn, Marianna; Shengli, Chen; Gui, Jiang; Elston, Dirk M.

    2018-01-01

    Background Basal cell carcinoma (BCC) has a characteristic stroma, but less is known about the dermal characteristics associated with melanoma in situ (MIS) and actinic keratosis (AK). Materials and methods Dermal changes were studied in 301 specimens of AK, BCC and MIS. Subsequently, blinded images of dermal changes from 90 randomly selected cases of those entities were used to assess the predictive value of the dermal changes. Agreement with the final diagnosis was calculated using kappa coefficient (κ). Results Fibromyxoid stroma was present in 82% of BCC cases; fibrous stroma was seen in 25% of BCC, 58% of MIS and 35.6% of AK specimens (p <0.05). A lichenoid inflammatory infiltrate was frequently associated with AK and a perifollicular infiltrate with periadnexal fibrosis with MIS. Blinded evaluation of images of the dermal changes associated with the tumors yielded the correct diagnosis in (54.4, 41.1 and 27.8%; average 41.2%) by the three appraisers. Coefficient of agreement in blinded imaged evaluation with the actual diagnosis was higher in the BCC and MIS compared with AK (κ = 0.37, p = 0.0001; κ = 0.2, p = 0.0005 and κ = −0.06, p = 0.84, respectively). Conclusion Dermal features may be helpful in predicting the correct diagnosis when tumor is not visible. PMID:24117926

  2. Characterization of dermal plates from armored catfish Pterygoplichthys pardalis reveals sandwich-like nanocomposite structure.

    Science.gov (United States)

    Ebenstein, Donna; Calderon, Carlos; Troncoso, Omar P; Torres, Fernando G

    2015-05-01

    Dermal plates from armored catfish are bony structures that cover their body. In this paper we characterized structural, chemical, and nanomechanical properties of the dermal plates from the Amazonian fish Pterygoplichthys pardalis. Analysis of the morphology of the plates using scanning electron microscopy (SEM) revealed that the dermal plates have a sandwich-like structure composed of an inner porous matrix surrounded by two external dense layers. This is different from the plywood-like laminated structure of elasmoid fish scales but similar to the structure of osteoderms found in the dermal armour of some reptiles and mammals. Chemical analysis performed using Fourier transform infrared spectroscopy (FTIR), differential scanning calorimetry (DSC) and X-ray diffraction (XRD) results revealed similarities between the composition of P. pardalis plates and the elasmoid fish scales of Arapaima gigas. Reduced moduli of P. pardalis plates measured using nanoindentation were also consistent with reported values for A. gigas scales, but further revealed that the dermal plate is an anisotropic and heterogeneous material, similar to many other fish scales and osteoderms. It is postulated that the sandwich-like structure of the dermal plates provides a lightweight and tough protective layer. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Collagen/chitosan based two-compartment and bi-functional dermal scaffolds for skin regeneration

    International Nuclear Information System (INIS)

    Wang, Feng; Wang, Mingbo; She, Zhending; Fan, Kunwu; Xu, Cheng; Chu, Bin; Chen, Changsheng; Shi, Shengjun; Tan, Rongwei

    2015-01-01

    Inspired from the sophisticated bilayer structures of natural dermis, here, we reported collagen/chitosan based two-compartment and bi-functional dermal scaffolds. Two functions refer to mediating rapid angiogenesis based on recombinant human vascular endothelial growth factor (rhVEGF) and antibacterial from gentamicin, which were encapsulated in PLGA microspheres. The gentamicin and rhVEGF encapsulated PLGA microspheres were further combined with collagen/chitosan mixtures in low (lower layer) and high (upper layer) concentrations, and molded to generate the two-compartment and bi-functional scaffolds. Based on morphology and pore structure analyses, it was found that the scaffold has a distinct double layered porous and connective structure with PLGA microspheres encapsulated. Statistical analysis indicated that the pores in the upper layer and in the lower layer have great variations in diameter, indicative of a two-compartment structure. The release profiles of gentamicin and rhVEGF exceeded 28 and 49 days, respectively. In vitro culture of mouse fibroblasts showed that the scaffold can facilitate cell adhesion and proliferation. Moreover, the scaffold can obviously inhibit proliferation of Staphylococcus aureus and Serratia marcescens, exhibiting its unique antibacterial effect. The two-compartment and bi-functional dermal scaffolds can be a promising candidate for skin regeneration. - Highlights: • The dermal scaffold is inspired from the bilayer structures of natural dermis. • The dermal scaffold has two-compartment structures. • The dermal scaffold containing VEGF and gentamicin encapsulated PLGA microspheres • The dermal scaffold can facilitate cell adhesion and proliferation

  4. Influence of limestone fillers on combustion characteristics of asphalt mortar for pavements

    DEFF Research Database (Denmark)

    Ke, Wu; Kai, Zhu; Wu, Hao

    2014-01-01

    Asphalt materials will be ignited and release significant toxic fumes within tunnel fires. Thus, combustion characteristics of asphalt materials used in road tunnel should be studied in order to limit such an adverse effect. In the present work we study the influence of limestone fillers on combu...

  5. Glycerol as high-permittivity liquid filler in dielectric silicone elastomers

    DEFF Research Database (Denmark)

    Mazurek, Piotr Stanislaw; Yu, Liyun; Skov, Anne Ladegaard

    of the composite. In combination with very low cost and easy preparation, the two property enhancements lead to a very attractive dielectric elastomer material. Experimental permittivity data are compared to various theoretical models that predict relative-permittivity changes as a function of filler loading...

  6. Copper-silver-titanium-tin filler metal for direct brazing of structural ceramics

    Science.gov (United States)

    Moorhead, Arthur J.

    1988-04-05

    A method of joining ceramics and metals to themselves and to one another at about 800.degree. C. is described using a brazing filler metal consisting essentially of 35 to 50 at. % copper, 40 to 50 at. % silver, 1 to 15 at. % titanium, and 2 to 8 at. % tin. This method produces strong joints that can withstand high service temperatures and oxidizing environments.

  7. Copper-silver-titanium filler metal for direct brazing of structural ceramics

    Science.gov (United States)

    Moorhead, Arthur J.

    1987-01-01

    A method of joining ceramics and metals to themselves and to one another is described using a brazing filler metal consisting essentially of 35 to 50 atomic percent copper, 15 to 50 atomic percent silver and 10 to 45 atomic percent titanium. This method produces strong joints that can withstand high service temperatures and oxidizing environments.

  8. Micro-nano filler metal foil on vacuum brazing of SiCp/Al composites

    Science.gov (United States)

    Wang, Peng; Gao, Zeng; Niu, Jitai

    2016-06-01

    Using micro-nano (Al-5.25Si-26.7Cu)- xTi (wt%, x = 1.0, 1.5, 2.0, 2.5 and 3.0) foils as filler metal, the research obtained high-performance joints of aluminum matrix composites with high SiC particle content (60 vol%, SiCp/Al-MMCs). The effect of brazing process and Ti content on joint properties was investigated, respectively. The experimental results indicate that void free dense interface between SiC particle and metallic brazed seam with C-Al-Si-Ti product was readily obtained, and the joint shear strength enhanced with increasing brazing temperature from 560 to 580 °C or prolonging soaking time from 10 to 90 min. Sound joints with maximum shear strength of 112.5 MPa was achieved at 580 °C for soaking time of 90 min with (Al-5.25Si-26.7Cu)-2Ti filler, where Ti(AlSi)3 intermetallic is in situ strengthening phase dispersed in the joint and fracture occured in the filler metal layer. In this research, the beneficial effect of Ti addition into filler metal on improving wettability between SiC particle and metallic brazed seam was demonstrated, and capable welding parameters were broadened for SiCp/Al-MMCs with high SiC particle content.

  9. Filler size effects on the conductivity of polymer nanocomposites: semiconductive phthalocyanine nanoparticles in epoxy matrices

    NARCIS (Netherlands)

    Yuan, M.; Brokken-Zijp, J.C.M.; Huijbregts, L.J.; With, de G.

    2008-01-01

    Three Cobalt(III) phthalocyanine (Phthalcon) powders with different particle sizes and chemical compositions, but almost equal XRD spectra and powder conductivity were synthesized and used as conductive fillers in crosslinked epoxy matrices. Two of these Phthalcons are new compounds. The relation

  10. Impact of Aggregate Gradation and Filler Type on Marshall Properties of Asphalt Concrete

    Directory of Open Access Journals (Sweden)

    saad I. Sarsam

    2015-09-01

    Full Text Available As asphalt concrete wearing course (ACWC is the top layer in the pavement structure, the material should be able to sustain stresses caused by direct traffic loading. The objective of this study is to evaluate the influence of aggregate gradation and mineral filler type on Marshall Properties. A detailed laboratory study is carried out by preparing asphalt mixtures specimens using locally available materials including asphalt binder (40-50 penetration grade, two types of aggregate gradation representing SCRB and ROAD NOTE 31 specifications and two types of mineral filler including limestone dust and coal fly ash. Four types of mixtures were prepared and tested. The first type included SCRB specification and limestone dust, the second type included SCRB specification and coal fly ash, the third types included ROAD NOTE 31 specification and limestone dust and the fourth type included ROAD NOTE 31 specification and coal fly ash. The optimum asphalt content of each type of mixtures was determined using Marshall Method of mix design. 60 specimen were prepared and tested with dimension of 10.16 cm in diameter and 6.35 cm in height. Results of this study indicated that aggregate gradation and filler type have a significant effect on optimum asphalt content and Marshall Properties. From the experimental data, it was observed that the value of Marshall Stability is comparatively higher when using fly ash as filler as compared to limestone dust.

  11. Synthesis of mesh-shaped calcia partially stabilized zirconia using eggshell membrane template as filler composite

    Directory of Open Access Journals (Sweden)

    Gema Gempita

    2017-08-01

    Full Text Available This experiment was conducted experimentally to synthesize Calcia Partially Stabilized Zirconia (Ca-PSZ by sol-gel method using eggshell membrane template as a composite filler. The eggshell membrane was used to produce a mesh shaped structure, which hopefully can improve the mechanical properties of the composite. Ca-PSZ filler was synthesized from ZrOCl2 precursor and Ca(NO32 stabilizer with a 24 hours immersion time. Ca-PSZ of synthesis then mixed with the resin matrix to test its composite hardness. The EDS characterization results suggested that the sample contained elements of zirconia, calcium, and oxygen. Whereas, the XRD characterization identified that crystal structures that formed in the sample were nano scale tetragonal. Characterization of SEM showed Ca-PSZ with mesh structured. The average composite hardness value was 15.79 VHN. The composites with Ca-PSZ-synthesized filler could be prepared and its hardness value was higher than the composite with Ca-PSZ filler in spherical particles, but the hardness was still below the composite on the market.

  12. Effect of Fibers and Filler Types on Fresh and Hardened Properties of Self-Compacting Concrete

    Directory of Open Access Journals (Sweden)

    Saeed K. Rejeb* , Majid Kh . N. Ayad A. M.

    2014-04-01

    Full Text Available This paper deals with studying the fresh and hardened properties of self-compacting concrete, by using three types of filler (silica fume, clinker powder & lime stone powder, and two types of fibers (steel & glass fibers with volume fractions of (0.5% and (0.1% respectively. For each type of fillers, the fresh properties are measured by using Slump test, J- ring and V- funnel, while hardened properties include the compressive strength, splitting tensile strength and flexural strength. The results show that adding fibers to the self-compacting concrete (SCC well reduces the workability and improves the hardened properties. Also, the study concluded that better workability is obtained by using (lime stone, silica fume and clinker powder as fillers, respectively. While the higher hardened properties are gained by using silica fume were rather than those of other types of fillers 

  13. Delayed-onset complications of facial soft tissue augmentation with permanent fillers in 85 patients

    NARCIS (Netherlands)

    Kadouch, Jonathan A.; Kadouch, Daniel J.; Fortuin, Shai; van Rozelaar, Leo; Karim, Refaat B.; Hoekzema, Rick

    2013-01-01

    To evaluate factors influencing the onset and type of adverse events in patients injected with permanent fillers in the face and to propose a therapeutic strategy for these complications. A prospectively attained series of 85 patients with delayed-onset complications after facial injection with

  14. Growth of Carbon Nanotubes on Clay: Unique Nanostructured Filler for High-Performance Polymer Nanocomposites

    NARCIS (Netherlands)

    Zhang, Wei-De; Phang, In Yee; Liu, Tianxi

    2006-01-01

    High-performance composites are produced using nanostructured clay-carbon nanotube (CNT) hybrids as a reinforcing filler. The intercalation of iron particles between the clay platelets serves as the catalyst for the growth of CNTs, while the platelets are exfoliated by the CNTs, forming the unique

  15. A survey of the bacterial diversity in the cup filler of dental chair units

    Directory of Open Access Journals (Sweden)

    Vítor Silva

    2011-09-01

    Full Text Available Water from the cup filler of dental chair units (CFDC was observed to contain sphingomonads, environmental mycobacteria and methylobacteria, among other minor bacteria. Some of the bacteria detected are recognized opportunistic pathogens. Some of these, tended to persist over time.

  16. 2 filler on the dielectric permittivity and electrical modulus of PMMA

    Indian Academy of Sciences (India)

    plex in solution phase.9 Debye theory of dipolar relaxation apprehends the ... present a study on the effect of Zn(NO3)2 filler in PMMA matrix, with a view to .... 3.4 EDX analysis. The quantitative and qualitative elemental analyses of the.

  17. Influence of filler alignment in the mechanical and electrical properties of carbon nanotubes/epoxy nanocomposites

    Energy Technology Data Exchange (ETDEWEB)

    Felisberto, M. [LPyMC, FCEyN-UBA and IFIBA-CONICET, Pab I Ciudad Universitaria, Buenos Aires 1428 (Argentina); INQUIMAE-CONICET-UBA, Pab II Ciudad Universitaria, Buenos Aires 1428 (Argentina); Arias-Duran, A. [LPyMC, FCEyN-UBA and IFIBA-CONICET, Pab I Ciudad Universitaria, Buenos Aires 1428 (Argentina); Ramos, J.A.; Mondragon, I. [Dep. Ingenieria Quimica y M. Ambiente. Esc. Politecnica. UPV/EHU, Pza. Europa 1, Donostia-San Sebastian 20018 (Spain); Candal, R. [INQUIMAE-CONICET-UBA, Pab II Ciudad Universitaria, Buenos Aires 1428 (Argentina); Escuela de Ciencia y Tecnologia-UNSAM, San Martin, Prov. De Buenos Aires (Argentina); Goyanes, S. [LPyMC, FCEyN-UBA and IFIBA-CONICET, Pab I Ciudad Universitaria, Buenos Aires 1428 (Argentina); Rubiolo, G.H., E-mail: rubiolo@cnea.gov.ar [LPyMC, FCEyN-UBA and IFIBA-CONICET, Pab I Ciudad Universitaria, Buenos Aires 1428 (Argentina); Dep. Materiales, Comision Nacional de Energia Atomica (CNEA-CAC), Avda Gral Paz 1499, B1650KNA San Martin (Argentina)

    2012-08-15

    In this work, we report the mechanical and electrical properties of carbon nanotubes/epoxy composites prepared with aligned and randomly oriented nanotubes as filler. The samples are disks of 30 mm in diameter and 3 mm in thickness. To obtain the carbon nanotubes alignment, an external electric field (250 VAC; 50 Hz) was applied through the thickness of the sample during all the cure process. The AC electrical current was measured, during the cure, as a strategy to determine the optimum time in which the alignment reaches the maximum value. DC conductivity measured after the cure shows a percolation threshold in the filler content one order of magnitude smaller for composites with aligned nanotubes than for composites with randomly oriented filler (from 0.06 to 0.5 wt%). In the percolation threshold, the achieved conductivity was 1.4 Multiplication-Sign 10{sup -5} Sm{sup -1}. In both cases, aligned and randomly distributed carbon nanotube composites, the wear resistance increases with the addition of the filler while the Rockwell hardness decreases independently of the nanotubes alignment.

  18. Effect of filler geometry on coefficient of thermal expansion in carbon nanofiber reinforced epoxy composites.

    Science.gov (United States)

    Cho, M; Jang, J; Suhr, J

    2011-02-01

    This study involves the investigation of the geometry effect of nano-fillers on thermally induced dimensional stability of epoxy composites by experimentally evaluating the linear coefficient of thermal expansion (CTE). Carbon nanofibers (CNF) were chosen as the filler in epoxy matrix to investigate the effect of an aspect ratio on the CTE of the nanocomposites at three different volume fractions of 0.5, 1, and 2% of the nano-filler. The composites were fabricated using a mechanical mixing method. The CTE values were evaluated by measuring thermal strains of the composites and also compared with a micromechanics model. It was observed that the composites with short CNF (average L/d = 10) show better thermal stability than one of the composites with long CNF (average L/d = 70), and the thermal stability of the composites was proportional to the volume fraction of the filler in each composite. In addition, the CTE of mutliwalled carbon nanotubes (MWNT) reinforced epoxy composites was evaluated and compared with the CTE of the CNF reinforced composites. Interestingly, the MWNT reinforced composites show the greatest thermal stability with an 11.5% reduction in the CTE over the pure epoxy. The experimental data was compared with micromechanics model.

  19. Effect of graphene oxide nano filler on dynamic behaviour of GFRP composites

    Science.gov (United States)

    Pujar, Nagabhushan V.; Nanjundaradhya, N. V.; Sharma, Ramesh S.

    2018-04-01

    Nano fillers like Alumina oxide, Titanium oxide, Carbon nano tube, Nano clay have been used to improve the mechanical and damping properties of fiber reinforced polymer composites. In the recent years Graphene oxide nano filler is receiving considerable attention for its outstanding properties. Literature available shows that Graphene oxide nano filler can be used to improve the mechanical properties. The use of Graphene oxide in vibration attenuation by enhancing the passive damping in fiber reinforced polymer composite has not been fully explored. The objective of this work is to investigate the dynamic behaviour of Glass fiber-reinforced composite embedded with Graphene oxide nano filler. Graphene oxide is dispersed in epoxy resin with various concentration (0.1%, 0.5% and 1%wt) using ultra-sonification process. Composite laminates were made using the traditional hand-lay-up followed by vacuum bag process. Experimental modal analysis using traditional `strike method' is used to evaluate modal parameters using FFT analyzer and Data Acquisition System. Experiments were carried out for two different fiber orientations viz 0 ➙ & 45 ➙ and two boundary conditions (Free-Free and Cantilever). The modal parameters such as natural frequency, mode shape, damping ratio were studied. This research work demonstrates the vibration damping behaviour with incorporation of Graphene oxide and provides a basic understanding of the damping characteristics in design and manufacture of high performance composites.

  20. Rubber Composites Based on Polar Elastomers with Incorporated Modified and Unmodified Magnetic Filler

    Directory of Open Access Journals (Sweden)

    Ján Kruželák

    2016-01-01

    Full Text Available Rubber magnetic composites were prepared by incorporation of unmodified and surface modified strontium ferrite into rubber matrices based on NBR and NBR/PVC. Strontium ferrite was dosed to the rubber matrices in concentration scale ranging from 0 to 100 phr. The main goal was to investigate the influence of the type of ferrite on the curing process, physical-mechanical and magnetic properties of composites. The mutual interactions between the filler and rubber matrices were investigated by determination of cross-link density and SEM analysis. The incorporation of magnetic fillers leads to the increase of cross-link density and remanent magnetic induction of composites. Moreover, the improvement of physical-mechanical properties was achieved in dependence on the content of magnetic fillers. Surface modification of ferrite contributed to the enhancement of adhesion on the interphase filler-rubber. It can be stated that ferrite exhibits reinforcing effect in the composite materials and this reinforcing behavior was emphasized with the increase in polarity of the rubber matrix.

  1. A study on engineering characteristics of asphalt concrete using filler with recycled waste lime.

    Science.gov (United States)

    Sung Do, Hwang; Hee Mun, Park; Suk keun, Rhee

    2008-01-01

    This study focuses on determining the engineering characteristics of asphalt concrete using mineral fillers with recycled waste lime, which is a by-product of the production of soda ash (Na(2)CO(3)). The materials tested in this study were made using a 25%, 50%, 75%, and 100% mixing ratio based on the conventional mineral filler ratio to analyze the possibility of using recycled waste lime. The asphalt concretes, made of recycled waste lime, hydrated lime, and conventional asphalt concrete, were evaluated through their fundamental engineering properties such as Marshall stability, indirect tensile strength, resilient modulus, permanent deformation characteristics, moisture susceptibility, and fatigue resistance. The results indicate that the application of recycled waste lime as mineral filler improves the permanent deformation characteristics, stiffness and fatigue endurance of asphalt concrete at the wide range of temperatures. It was also determined that the mixtures with recycled waste lime showed higher resistance against stripping than conventional asphalt concrete. It was concluded from various test results that a waste lime can be used as mineral filler and, especially, can greatly improve the resistance of asphalt concrete to permanent deformation at high temperatures.

  2. Analysis of filler--fibre interaction in fly ash filled short fibre-epoxy ...

    Indian Academy of Sciences (India)

    Size and aspect ratio are believed to influence the rheology or the flow in the mixture and in turn the mechanical performance of the composites. Fillers and fibres when used in combination are expected to complement each other's performance resulting in better properties for the composite. They also reduce the extent of ...

  3. Composite biomaterials with chemical bonding between hydroxyapatite filler particles and PEG/PBT copolymer matrix

    NARCIS (Netherlands)

    Liu, Qing; de Wijn, J.R.; van Blitterswijk, Clemens

    1998-01-01

    In an effort to make composites from hydroxyapatite and a PEG/PBT copolymer (PolyactiveTM 70/30), chemical linkages were introduced between the filler particles and polymer matrix using hexamethylene diisocyanate as a coupling agent. Infrared spectra (IR) and thermal gravimetric analysis (TGA)

  4. Modification of Sorghum Starch-Cellulose Bioplastic with Sorghum Stalks Filler

    Directory of Open Access Journals (Sweden)

    Yuli Darni

    2017-05-01

    Full Text Available This study evaluated the feasibility of bioplastics production by various ratio of sorghum starch and cellulose from red seaweed Eucheuma spinossum, and the use of glycerol as plasticizer and sorghum stalks as filler. Solid-liquid matrix transition should be far over the operating temperature of gelatinization and extracted at 95oC in order to avoid the loss of conductivity. The analyzed variables were starch and cellulose seaweed Eucheuma spinossum and the addition of variation of filler. Sorghum stalk could be expected to affect the mechanical and physical properties of bioplastics. A thin sheet of plastic (plastic film was obtained as a result that have been tested mechanically to obtain the best condition for the formulation of starch-cellulose 8.5:1.5 (g/g. From the result of morphological studies, the fillers in the mixture composites were more randomly in each product and the addition of filler can increase mechanical properties of bioplastics. Chemical modification had a major effect on the mechanical properties. The phenomena of degradation and thermoplasticization were visible at chemical changes that can be observed in FTIR spectrum test results.

  5. Potential use of clay from Burkina Faso as filler in rubber production ...

    African Journals Online (AJOL)

    raw clay materials deposit in Burkina Faso have been characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM) and chemical analysis to evaluate their potentialities to be used in rubber compounds production as filler. The samples are composed principally by aolinite, illite and quartz. The rubber ...

  6. THE FORMATION OF BIMETALLIC CONNECTION IN WELDER DEPOSITION UNDER LASER WELDING WITH THE FILLER WIRE FEED

    Directory of Open Access Journals (Sweden)

    A. P. Yelistratov

    2017-01-01

    Full Text Available The metallurgical and technological features of welding deposition in a robotic unit with a semiconductor laser are analyzed. The prospects of using beam with low energy density in the spot heating for applying metallic layers using filler wire are shown. 

  7. Using Raman spectroscopic imaging for non-destructive analysis of filler distribution in chalk filled polypropylene

    DEFF Research Database (Denmark)

    Boros, Evelin; Porse, Peter Bak; Nielsen, Inga

    2016-01-01

    A feasibility study on using Raman spectral imaging for visualization and analysis of filler distribution in chalk filled poly-propylene samples has been carried out. The spectral images were acquired using a Raman spectrometer with 785 nm light source.Eight injection-molded samples with concentr...

  8. Influence of heat conductivity on the performance of RTV SIR coatings with different fillers

    Energy Technology Data Exchange (ETDEWEB)

    Siderakis, K [High Voltage Laboratory, Department of Electrical and Computer Engineering, University of Patras, GR-26110 Patras (Greece); Agoris, D [High Voltage Laboratory, Department of Electrical and Computer Engineering, University of Patras, Greece, GR-26500, Rion, Greece (Greece); Gubanski, S [High Voltage Laboratory, Department of Electric Power Engineering, Chalmers University of Technology, S-41296, Gothenburg (Sweden)

    2005-10-07

    Room temperature vulcanized silicone rubber (RTV SIR) coatings are employed in order to improve the pollution performance of high voltage ceramic insulators by imparting surface hydrophobicity. In this paper, the performance of three RTV SIR coatings containing different fillers is investigated in a salt-fog test. Alumina trihydrate (ATH) and silica are the fillers included in the formulation, aiming to increase the material endurance to the energy supplied by the surface electrical activity during periods of hydrophobicity loss. The primary action of these fillers is to increase the material heat conductivity, i.e. the amount of energy conducted to the substrate. In addition, in the case of ATH relief is also achieved due to particle decomposition. The results indicate that for the compositions commercially available, where low amounts of fillers are used, and under the conditions of the test, ATH filled coatings performed better than the silica filled ones. This is attributed to ATH decomposition which further relieves the material structure and therefore decelerates material aging.

  9. Electro-mechanical properties of hydrogel composites with micro- and nano-cellulose fillers

    International Nuclear Information System (INIS)

    Shahid U N, Mohamed; Deshpande, Abhijit P; Rao, C Lakshmana

    2015-01-01

    Stimuli responsive cross-linked hydrogels are of great interest for applications in diverse fields such as sensors and biomaterials. In this study, we investigate polymer composites filled with cellulose fillers. The celluloses used in making the composites were a microcrystalline cellulose of commercial grade and cellulose nano-whiskers obtained through acid hydrolysis of microcrystalline cellulose. The filler concentration was varied and corresponding physical, mechanical and electro-mechanical characterization was carried out. The electro-mechanical properties were determined using a quasi-static method. The fillers not only enhance the mechanical properties of the composite by providing better reinforcement but also provide a quantitative electric potential in the composite. The measurements reveal that the polymer composites prepared from two different cellulose fillers possess a quantitative electric potential which can be utilized in biomedical applications. It is argued that the mechanism behind the quantitative electric potential in the composites is due to streaming potentials arising due to electrical double layer formation. (paper)

  10. Influence of Hybrid Fillers on Thermal Conductivity of Nylon-6/Graphene Composites

    Directory of Open Access Journals (Sweden)

    SONG Na

    2018-03-01

    Full Text Available The thermal insulating properties of polymer greatly restrict the application of polymer as the thermal conductivity materials in industry. Multilayer graphene was chosen as a filler due to its unique thermal transfer property. The effect of alumina oxide (Al2O3 and silicon carbide (SiC with graphene as hybrid fillers on thermal conductivity of polymers was also explored. The thermal conductivity of the composites enhances 161% with 3%(mass fraction graphene content compared to pure nylon-6(PA6. The thermal conductivity of PA6 composites is within 0.653-4.307W·m-1·K-1 by adjusting hybrid fillers content and the ratio of graphene with Al2O3 and SiC. The best thermal conductivity is 20 times higher than the pure PA6. It is no doubt that the exploration can provide valuable experimental basis for extending the utilization of graphene as thermal conductivity filler and the application of PA6 thermal conductivity materials in industry.

  11. Investigation of Properties of Asphalt Concrete Containing Boron Waste as Mineral Filler

    Directory of Open Access Journals (Sweden)

    Cahit GÜRER

    2016-05-01

    Full Text Available During the manufacture of compounds in the boron mining industry a large quantity of waste boron is produced which has detrimental effects on the environment. Large areas have to be allocated for the disposal of this waste. Today with an increase in infrastructure construction, more efficient use of the existing sources of raw materials has become an obligation and this involves the recycling of various waste materials. Road construction requires a significant amount of raw materials and it is possible that substantial amounts of boron-containing waste materials can be recycled in these applications. This study investigates the usability of boron wastes as filler in asphalt concrete. For this purpose, asphalt concrete samples were produced using mineral fillers containing 4%, 5%, 6%, 7% and 8% boron waste as well as a 6% limestone filler (6%L as the control sample. The Marshall Design, mechanical immersion and Marshall Stability test after a freeze-thaw cycle and indirect tensile stiffness modulus (ITSM test were performed for each of the series. The results of this experimental study showed that boron waste can be used in medium and low trafficked asphalt concrete pavements wearing courses as filler.

  12. Treatment of a traumatic atrophic depressed scar with hyaluronic acid fillers: a case report

    Directory of Open Access Journals (Sweden)

    Hussain SN

    2017-08-01

    Full Text Available Syed Nazim Hussain,1 Greg J Goodman,2,3 Eqram Rahman4 1Royal Lush Skin Hair & Laser Clinic, Saket, New Delhi, India; 2Department of Primary Care, Monash University, Clayton, 3Skin and Cancer Foundation Inc, Carlton, VIC, Australia; 4Faculty of Medical Science, Postgraduate Medical Institute, Anglia Ruskin University, Chelmsford, UK Background: Hyaluronic acid filler has been documented in the treatment of atrophic depressed acne scars relatively frequently in the literature but rarely in chronic depressed traumatic atrophic facial scars.Methods: This case report discusses the use of hyaluronic acid fillers in the correction of a post-traumatic facial atrophic scar on the right cheek.Results: The right cheek scar was substantially corrected with one session of two different hyaluronic acids injected in a deep and superficial plane.Conclusion: Relatively accurate, simple and effective correction of this atrophic traumatic scar may suggest that fillers are a suitable alternative to surgery for such scars. Keywords: scarring, scar correction, filler, hyaluronic acid, facial scar

  13. Surface Modified Characteristics of the Tetracalcium Phosphate as Light-Cured Composite Resin Fillers

    Directory of Open Access Journals (Sweden)

    Wen-Cheng Chen

    2014-01-01

    Full Text Available The objectives of this study are to characterize the properties of light-cured composite resins that are reinforced with whisker surface-modified particles of tetracalcium phosphate (TTCP and to investigate the influence of thermal cycling on the reinforced composites properties. The characteristics of ultimate diametral tensile strength (DTS, moduli, pH values, and fracture surfaces of the samples with different amounts of surface-modified TTCP (30%–60% were determined before and after thermal cycling between 5°C and 55°C in deionized water for 600 cycles. The trends of all groups were ductile prior to thermal cycling and the moduli of all groups increased after thermal cycling. The ductile property of the control group without filler was not significantly affected. Larger amounts of fillers caused the particles to aggregate, subsequently decreasing the resin’s ability to disperse external forces and leading to brittleness after thermal cycling. Therefore, the trend of composite resins with larger amounts of filler would become more brittle and exhibited higher moduli after thermal cycling. This developed composite resin with surface modified-TTCP fillers has the potential to be successful dental restorative materials.

  14. Use of filler materials to aid spent nuclear fuel dry storage

    International Nuclear Information System (INIS)

    Anderson, K.J.

    1981-09-01

    The use of filler materials (also known as stabilizer or encapsulating materials) was investigated in conjunction with the dry storage of irradiated light water reactor (LWR) fuel. The results of this investigation appear to be equally valid for the wet storage of fuel. The need for encapsulation and suitable techniques for closing was also investigated. Various materials were reviewed (including solids, liquids, and gases) which were assumed to fill the void areas within a storage can containing either intact or disassembled spent fuel. Materials were reviewed and compared on the basis of cost, thermal characteristics, and overall suitability in the proposed environment. A thermal analysis was conducted to yield maximum centerline and surface temperatures of a design basis fuel encapsulated within various filler materials. In general, air was found to be the most likely choice as a filler material for the dry storage of spent fuel. The choice of any other filler material would probably be based on a desire, or need, to maximize specific selection criteria, such as surface temperatures, criticality safety, or confinement

  15. Enhancement of Fracture Toughness of Epoxy Nanocomposites by Combining Nanotubes and Nanosheets as Fillers.

    Science.gov (United States)

    Domun, Nadiim; Paton, Keith R; Hadavinia, Homayoun; Sainsbury, Toby; Zhang, Tao; Mohamud, Hibaaq

    2017-10-19

    In this work the fracture toughness of epoxy resin has been improved through the addition of low loading of single part and hybrid nanofiller materials. Functionalised multi-walled carbon nanotubes (f-MWCNTs) was used as single filler, increased the critical strain energy release rate, G IC , by 57% compared to the neat epoxy, at only 0.1 wt% filler content. Importantly, no degradation in the tensile or thermal properties of the nanocomposite was observed compared to the neat epoxy. When two-dimensional boron nitride nanosheets (BNNS) were added along with the one-dimensional f-MWCNTs, the fracture toughness increased further to 71.6% higher than that of the neat epoxy. Interestingly, when functionalised graphene nanoplatelets (f-GNPs) and boron nitride nanotubes (BNNTs) were used as hybrid filler, the fracture toughness of neat epoxy is improved by 91.9%. In neither of these hybrid filler systems the tensile properties were degraded, but the thermal properties of the nanocomposites containing boron nitride materials deteriorated slightly.

  16. Hybrid composite based on poly(vinyl alcohol) and fillers from renewable resources

    Science.gov (United States)

    Hybrid composite laminates consisting of polyvinyl alcohol (PVA) as continuous phase (33% by weight) and lignocellulosic fillers, derived from sugarcane bagasse, apple and orange waste (22% by weight) were molded in a carver press in the presence of water and glycerol such as platicizers agents. Cor...

  17. Clinical Application of Earlobe Augmentation with Hyaluronic Acid Filler in the Chinese Population.

    Science.gov (United States)

    Qian, Wei; Zhang, Yan-Kun; Cao, Qian; Hou, Ying; Lv, Wei; Fan, Ju-Feng

    2017-02-01

    Larger earlobes, which are a symbol of "richness" in traditional Chinese culture, are favored by Chinese patients. The objective of this paper is to investigate the application of earlobe augmentation with hyaluronic acid (HA) filler injection and its clinical effects in the Chinese population. A total of 19 patients (38 ears) who received earlobe augmentation with HA filler injections between March 2013 and March 2015 were included. The clinical effects, duration, and complications of these cases were investigated. All patients who received earlobe HA injections showed immediate postoperative effects with obvious morphological improvement of their earlobes. The volume of HA filler injected into each ear was 0.3-0.5 ml. The duration of the effect was 6-9 months. Two of the 19 cases (3 ears) demonstrated mild bruising at the injection site, but the bruising completely disappeared within 7 days after the injection. No vascular embolism, infection, nodule, or granuloma complications were observed in the studied group. The application of earlobe augmentation with HA filler injection is a safe, effective, simple procedure for earlobe shaping. It has an easy clinical application with good clinical prospects. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  18. Enhancement of Fracture Toughness of Epoxy Nanocomposites by Combining Nanotubes and Nanosheets as Fillers

    Directory of Open Access Journals (Sweden)

    Nadiim Domun

    2017-10-01

    Full Text Available In this work the fracture toughness of epoxy resin has been improved through the addition of low loading of single part and hybrid nanofiller materials. Functionalised multi-walled carbon nanotubes (f-MWCNTs was used as single filler, increased the critical strain energy release rate, GIC, by 57% compared to the neat epoxy, at only 0.1 wt% filler content. Importantly, no degradation in the tensile or thermal properties of the nanocomposite was observed compared to the neat epoxy. When two-dimensional boron nitride nanosheets (BNNS were added along with the one-dimensional f-MWCNTs, the fracture toughness increased further to 71.6% higher than that of the neat epoxy. Interestingly, when functionalised graphene nanoplatelets (f-GNPs and boron nitride nanotubes (BNNTs were used as hybrid filler, the fracture toughness of neat epoxy is improved by 91.9%. In neither of these hybrid filler systems the tensile properties were degraded, but the thermal properties of the nanocomposites containing boron nitride materials deteriorated slightly.

  19. Enhanced Thermal Conductivity of Copper Nanofluids: The Effect of Filler Geometry.

    Science.gov (United States)

    Bhanushali, Sushrut; Jason, Naveen Noah; Ghosh, Prakash; Ganesh, Anuradda; Simon, George P; Cheng, Wenlong

    2017-06-07

    Nanofluids are colloidal dispersions that exhibit enhanced thermal conductivity at low filler loadings and thus have been proposed for heat transfer applications. Here, we systematically investigate how particle shape determines the thermal conductivity of low-cost copper nanofluids using a range of distinct filler particle shapes: nanospheres, nanocubes, short nanowires, and long nanowires. To exclude the potential effects of surface capping ligands, all the filler particles are kept with uniform surface chemistry. We find that copper nanowires enhanced the thermal conductivity up to 40% at 0.25 vol % loadings; while the thermal conductivity was only 9.3% and 4.2% for the nanosphere- and nanocube-based nanofluids, respectively, at the same filler loading. This is consistent with a percolation mechanism in which a higher aspect ratio is beneficial for thermal conductivity enhancement. To overcome the surface oxidation of the copper nanomaterials and maintain the dispersion stability, we employed polyvinylpyrrolidone (PVP) as a dispersant and ascorbic acid as an antioxidant in the nanofluid formulations. The thermal performance of the optimized fluid formulations could be sustained for multiple heating-cooling cycles while retaining stability over 1000 h.

  20. Influence of filler charge on gloss of composite materials before and after in vitro toothbrushing.

    Science.gov (United States)

    Jassé, Fernanda Ferreira; de Campos, Edson Alves; Lefever, Dorien; Di Bella, Enrico; Salomon, Jean Pierre; Krejci, Ivo; Ardu, Stefano

    2013-11-01

    This study evaluated the gloss behaviour of experimental resin composites loaded with different filler percentages, immediately after polishing and after toothbrushing simulation. Sixteen disc-shaped specimens were fabricated for each different-charged composite (40%, 50%, 60%, 70% and 75%) and polished with SiC abrasive papers. Gloss measurements were made prior to simulated toothbrushing. The specimens were subjected to the simulation for 5, 15, 30 and 60 min using an electrical toothbrush with a standardized pressure while being immersed in a toothpaste/artificial saliva slurry. Baseline composite gloss values ranged from 69.7 (40%) to 81.3 (75%) GU (gloss units) and from 18.1 (40%) to 32.3 (75%) GU after 1h of brushing. Highest gloss values were obtained by 75%-charged resin, while the lowest values were obtained by the 40%-charged one. All tested materials showed a gloss decrease. However, the higher filler load a composite resin has, the higher gloss it can achieve. Gloss of resin composite materials is an important factor in determining aesthetic success of anterior restorations, and this property may vary according to the filler charge of the restorative material. Higher filler load of a composite resin results in higher gloss values. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Polyols as filler-binders for disintegrating tablets prepared by direct compaction

    NARCIS (Netherlands)

    Bolhuis, Gerad K.; Rexwinkel, Erik G.; Zuurman, Klaas

    Background: Although polyols are frequently used as tablet excipients in lozenges, chewing tablets, and orodisperse tablets, special directly compressible (DC) forms are recommended as filler-binder in common disintegrating tablets. Aim: In this article, DC types of isomalt, lactitol, mannitol,

  2. DC Calcium lactate, a new filler-binder for direct compaction of tablets

    NARCIS (Netherlands)

    Bolhuis, GK; Eissens, AC; Zoestbergen, E

    2001-01-01

    In this paper, a directly compressible form of calcium lactate is introduced as a filler-binder for direct compaction of tablets. Calcium lactate is one of the most important calcium sources and has, in comparison with other organic calcium salts, a good solubility and bioavailability. Two different

  3. Evaluation of the filler packing structures in dental resin composites: From theory to practice.

    Science.gov (United States)

    Wang, Ruili; Habib, Eric; Zhu, X X

    2018-07-01

    The aim of this study is to evaluate the packing properties of uniform silica particles and their mixture with secondary particles yielding maximally loaded dental composites. We intend to verify the difference between the idealized models (the close-packed structures and the random-packed structures) and the actual experimental results, in order to provide guidance for the preparation of dental composites. The influence of secondary particle size and the resin composition on the physical-mechanical properties and the rheological properties of the experimental dental composites was also investigated. Silica particles (S-920, S-360, and S-195) with average diameters of 920, 360, and 195nm were synthesized via the Stöber process. Their morphology and size distribution were determined by field-emission scanning electron microscopy and laser particle sizer. A series of silica fillers, S-920, S-920+195, S-920+360, and S-920+360+195, were then formulated with two Bis-GMA/TEGDMA resins (weight ratios of 70:30 and 50:50). For these experimental dental composites, their maximum filler loadings were assessed and compared to the theory. The mechanical properties, degree of conversion, depth of cure, and polymerization shrinkage of these composites were then evaluated. Their rheological behaviors were measured with a rheometer. Unimodal S-920 had the maximally filler loading of 70.80wt% with the 5B5T resin, close to the theoretical estimation of the random loose packing (71.92wt%). The maximum loading of the S-920+360+195 filled composite was 72.92wt% for the same resin, compared to the theoretical estimation of 89.29wt% obtained for the close-packed structures. These findings indicate that random loose packing matches more closely to the real packing state for the filler formulations used. When maximally loaded, the composite with S-920+360+195 produced the best mechanical properties and the lowest polymerization shrinkage. The degree of conversion and depth of cure were

  4. Inactive Mineral Filler as a Stiffness Modulus Regulator in Foamed Bitumen-Modified Recycled Base Layers

    Science.gov (United States)

    Buczyński, Przemyslaw; Iwański, Marek

    2017-10-01

    The article presents the results of a cold recycled mix test with a foam bitumen including the addition of the inactive mineral filler as a dust of basalt. Basalt dust was derived from dedusting system by extraction of aggregates in the mine. Assessment of the impact of a basalt dust on the properties of a recycled base layer was carried out in terms of the amount of mineral filler (basalt) in the composition of the mineral mixture. This experiment involved a dosing of mineral filler in range from 5 to 20% with steps of 7.5% in the mineral mixture composition. The foamed bitumen was performed at optimum foaming process settings (ie. bitumen temperature, air pressure) and at 2.5% of the water content. The amount of a hydraulic binder as a Portland cement was 2.0%. The evaluation of rheological properties allowed to determine whether the addition of inactive mineral fillers can act as a stiffness modulus controller in the recycled base layer. The analysis of the rheological properties of a recycled base layer in terms of the amount of inactive fillers was performed in accordance with given standard EN 12697-26 Annex D. The study was carried out according to the direct tension-compression test methodology on cylindrical samples. The sample was subjected to the oscillatory sinusoidal strain ε0 < 25με. Studies carried out at a specific temperature set-points: - 7°C, 5°C, 13°C, 25°C and 40°C and at the frequency 0.1 Hz, 0.3 Hz, 1 Hz, 3 Hz, 10 Hz and 20 Hz. The obtained results allow to conclude that the use of an inactive filler can reduce the stiffness of an appropriate designed mixes of the cold recycled foundation. In addition, the analysis of the relation E‧-E″ showed a similar behaviour of a recycled base, regardless of the amount of inactive fillers in the mix composition, at high temperatures/high frequency of induced load.

  5. Effect of filler type on 3-body abrasion of dental composite

    Directory of Open Access Journals (Sweden)

    Yasini E.

    2005-06-01

    Full Text Available Statement of Problem: The relatively poor wear resistance of dental composite in stress bearing posterior situations has restricted wider clinical application of this restorative material. Purpose: The aim of this study was to evaluate the three body abrasive wear of a dental composite based on a new filler (leucite: KAl Si2O6 and to compare it with the wear resistance of a composite based on commonly used Aluminium – Barium Silicate filler. Materials and Methods: This research was an interventional study done in Iran polymer institute. Five specimens were considered in each group. All ceramic IPS Empress® (Ivoclar- Vivadent ingots based on leucite crystals were ball milled, passed through an 800 sieve and used as filler. Experimental composites were prepared by mixing the silane- treated fillers with monomers (BisGMA and TEGDMA. Camphorquinone and amine were used as photoinitiator system. Degree of conversion of the light-cured and post-cured composites was measured using FTIR spectroscopy. The prepared pastes were inserted into plexy-glass mold and light cured (700 mw/cm2, 40 s. Then for maximum degree of conversion specimens were post- cured (120ºC, 5 hours. Three body abrasion wear testing was performed using a wear machine with 50 rpm rotational movement. In this machine, pumice (150 meshes was used as the third body. Weight loss of specimens in each group was measured by balance after each 50 hours. After wear testing SEM examination was made specimens in each group. The data were analyzed and compared using ANOVA and Tukey HSD tests (P<0.05. Tetric Ceram was tested as commercial composite. Results: There were significantly differences between three body abrasive wear of composites. The ranking from lowest to highest was as follows: leucite composite (19% < Tetric Ceram (22% < glass composite (28%. leucite composite showed the highest wear resistance value, propably due to the crystalliniy and hardness of filler. Conclusion

  6. Effect of pyrophyllite filler treatment toward water absorbance rate of SAPC and its application test

    International Nuclear Information System (INIS)

    Jadigia Ginting

    2015-01-01

    An optimization treatment to pyrophyllite filler has been done to synthesis super absorbent polymers composite (SAPC) with copolymerization of acrylic. Pyrophyllite is one of a silicate mineral with chemical formula Al 2 Si 4 O 10 (OH) 2 having a reactive functional group -OH that easily making a bonding and therefore it is suitable for water absorbance materials. The pyrophyllite were studied as its weight composition and its powder-size in the SAPC preparation. To obtain the fine-size, the filler pyrophyllite were milled with high energy mechanical milling (HEMM) into divers hours of milling. The syntheses were carried out by using the settle method from Chemicals Engineering group of ITB Bandung. The samples of SAPC-prflt were then characterized with fourier-transform infra red spectroscopy (FTIR), Xray diffraction (XRD) and scanning electron microscopy(SEM). Effect of filler treatment toward water absorbance rate is the SAPC-prflt with 0.5 gr filler having the highest gradient absorbance 1,610; SAPC prflt which milled for 9 hours has gradient absorbance 1,526; SAPC-prflt after hot water test at 40°C has gradient absorbence 2,241 and SAPC-prflt as pampers test has the gradient absorbance 1,607. XRD data analysis showed a broad peak 2 θ at scale 5 w which correspond to the micrographs picture of the sample which has 0.5 gr filler pyrophyllite and sample after milled for 9 hours, that proposed increase the sample strength and stability which induce the increasing of its water absorbance.

  7. Rubber materials from elastomers and nanocellulose powders: filler dispersion and mechanical reinforcement.

    Science.gov (United States)

    Fumagalli, Matthieu; Berriot, Julien; de Gaudemaris, Benoit; Veyland, Anne; Putaux, Jean-Luc; Molina-Boisseau, Sonia; Heux, Laurent

    2018-04-04

    Rubber materials with well-dispersed fillers and large mechanical reinforcement have been obtained by melt-processing a diene elastomer matrix and tailored nanocellulose powders having both a high specific surface area and a modified interface. Such filler powders with a specific surface area of 180 m2 g-1 and 100 m2 g-1 have been obtained by freeze-drying suspensions of short needle-like cellulose nanocrystals (CNCs) and entangled networks of microfibrillated cellulose (MFC) in tert-butanol/water, respectively. A quantitative and toposelective filler surface esterification was performed using a gas-phase protocol either with palmitoyl chloride (PCl) to obtain a hydrophobic but non-reactive nanocellulose interface, or with 3,3'-dithiopropionic acid chloride (DTACl) to introduce reactive groups that can covalently bind the nanocellulose interface to the dienic matrix in a subsequent vulcanization process. A set of filled materials was prepared varying the filler morphology, interface and volume fraction. Transmission electron microscopy images of ultrathin cryo-sections showed that modified nanocellulose fillers presented a relatively homogeneous distribution up to a volume fraction of 20%. The materials also exhibited a significant modulus increase, while keeping an extensibility in the same range as that of the neat matrix. Strikingly, in the case of the reactive interface, a strong stress-stiffening behavior was evidenced from the upward curvature of the tensile curve, leading to a large increase of the ultimate stress (up to 7 times that of the neat matrix). Taken together, these properties, which have never been previously reported for nanocellulose-filled elastomers, match well the mechanical characteristics of industrial carbon black or silica-loaded elastomers.

  8. Effect of Biomass Waste Filler on the Dielectric Properties of Polymer Composites

    Directory of Open Access Journals (Sweden)

    Yew Been Seok

    2016-07-01

    Full Text Available The effect of biomass waste fillers, namely coconut shell (CS and sugarcane bagasse (SCB on the dielectric properties of polymer composite was investigated. The aim of this study is to investigate the potential of CS and SCB to be used as conductive filler (natural source of carbon in the polymer composite. The purpose of the conductive filler is to increase the dielectric properties of the polymer composite. The carbon composition the CS and SCB was determine through carbon, hydrogen, nitrogen and sulphur (CHNS elemental analysis whereas the structural morphology of CS and SCB particles was examined by using scanning electron microscope. Room temperature open-ended coaxial line method was used to determine the dielectric constant and dielectric loss factor over broad band frequency range of 200 MHz-20 GHz. Based on this study, the results found that CS and SCB contain 48% and 44% of carbon, which is potentially useful to be used as conductive elements in the polymer composite. From SEM morphology, presence of irregular shape particles (size ≈ 200 μm and macroporous structure (size ≈ 2.5 μm were detected on CS and SCB. For dielectric properties measurement, it was measured that the average dielectric constant (ε' is 3.062 and 3.007 whereas the average dielectric loss factor (ε" is 0.282 and 0.273 respectively for CS/polymer and SCB/polymer composites. The presence of the biomass waste fillers have improved the dielectric properties of the polymer based composite (ε' = 2.920, ε" = 0.231. However, the increased in the dielectric properties is not highly significant, i.e. up to 4.86 % increase in ε' and 20% increase in ε". The biomass waste filler reinforced polymer composites show typical dielectric relaxation characteristic at frequency of 10 GHz - 20 GHz and could be used as conducting polymer composite for suppressing EMI at high frequency range.

  9. Potential dermal wound healing agent in Blechnum orientale Linn

    Directory of Open Access Journals (Sweden)

    Lim Yau

    2011-08-01

    Full Text Available Abstract Background Blechnum orientale Linn. (Blechnaceae is used ethnomedicinally to treat wounds, boils, blisters or abscesses and sores, stomach pain and urinary bladder complaints. The aim of the study was to validate the ethnotherapeutic claim and to evaluate the effects of B. orientale water extract on wound healing activity. Methods Water extract of B. orientale was used. Excision wound healing activity was examined on Sprague-Dawley rats, dressed with 1% and 2% of the water extract. Control groups were dressed with the base cream (vehicle group, negative control and 10% povidone-iodine (positive control respectively. Healing was assessed based on contraction of wound size, mean epithelisation time, hydroxyproline content and histopathological examinations. Statistical analyses were performed using one way ANOVA followed by Tukey HSD test. Results Wound healing study revealed significant reduction in wound size and mean epithelisation time, and higher collagen synthesis in the 2% extract-treated group compared to the vehicle group. These findings were supported by histolopathological examinations of healed wound sections which showed greater tissue regeneration, more fibroblasts and angiogenesis in the 2% extract-treated group. Conclusions The ethnotherapeutic use of this fern is validated. The water extract of B. orientale is a potential candidate for the treatment of dermal wounds. Synergistic effects of both strong antioxidant and antibacterial activities in the extract are deduced to have accelerated the wound repair at the proliferative phase of the healing process.

  10. Integra artificial skin dermal regeneration templates in burn scar surgery

    International Nuclear Information System (INIS)

    Rexon Ngim

    1999-01-01

    Integra artificial skin is a porous matrix used as a permanent dermal replacement. Developed in the 1970's, it has been used successfully in the treatment of acute bums requiring full or deep partial thickness skin replacement. Three patients with burn scars received Integra Artificial Skin to resurface various areas of burn scars and also contractures. The first was a 24-year-old woman who had two pieces of Integra to resurface a forearm/elbow/wrist defect. The second was a 28-year-old woman who had two pieces of Integra to resurface a neck contracture. The third was a 44 year-old woman who had two pieces to correct severe burn contractures/ scars of her hands. The results of these three patients, probably the first time Integra was used for bum scar and contracture revision, indicate that there is a place for Integra in Burn Scar surgery. However, the basic principle of its application must be adhered to. These include excision to remove the complete scar, recreation of original size of skin defect and meticulous application of the Artificial Skin and its care post-operatively. Details of its application will be highlighted

  11. Occular and dermal toxicity of Jatropha curcas phorbol esters.

    Science.gov (United States)

    Devappa, Rakshit K; Roach, Joy S; Makkar, Harinder P S; Becker, Klaus

    2013-08-01

    Jatropha curcas seeds are a promising feedstock for biodiesel production. However, Jatropha seed oil and other plant parts are toxic due to the presence of phorbol esters (PEs). The ever-increasing cultivation of toxic genotype of J. curcas runs the risk of increased human exposure to Jatropha products. In the present study, effects of J. curcas oil (from both toxic and nontoxic genotypes), purified PEs-rich extract and purified PEs (factors C1, C2, C(3mixture), (C4+C5)) on reconstituted human epithelium (RHE) and human corneal epithelium (HCE) were evaluated in vitro. The PEs were purified from toxic Jatropha oil. In both RHE and HCE, the topical application of PEs containing samples produced severe cellular alterations such as marked oedema, presence of less viable cell layers, necrosis and/or partial tissue disintegration in epithelium and increased inflammatory response (interleukin-1α and prostaglandin E2). When compared to toxic oil, histological alterations and inflammatory response were less evident (PJatropha PEs are toxic towards RHE and HCE models, which represents dermal and occular toxicity respectively. Data obtained from this study would aid in the development of safety procedures for Jatropha biodiesel industries. It is advised to use protective gloves and glasses when handling PEs containing Jatropha products. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. The structure and mechanical design of rhinoceros dermal armour.

    Science.gov (United States)

    Shadwick, R E; Russell, A P; Lauff, R F

    1992-09-29

    The collagenous dermis of the white rhinoceros forms a thick, protective armour that is highly specialized in its structure and material properties compared with other mammalian skin. Rhinoceros skin is three times thicker than predicted allometrically, and it contains a dense and highly ordered three-dimensional array of relatively straight and highly crosslinked collagen fibres. The skin of the back and flanks exhibits a steep stress-strain curve with very little 'toe' region, a high elastic modulus (240 MPa), a high tensile strength (30 MPa), a low breaking strain (0.24) and high breaking energy (3 MJm-3) and work of fracture (78 kJm-2). By comparison, the belly skin is somewhat less stiff, weaker, and more extensible. In compression, rhinoceros skin withstands average stresses and strains of 170 MPa and 0.7, respectively, before yielding. As a biological material, rhinoceros dorsolateral skin has properties that are intermediate between those of 'normal' mammalian skin and tendons. This study shows that the dermal armour of the rhinoceros is very well adapted to resist blows from the horns of conspecifics, as might occur during aggressive behaviour, due to specialized material properties as well as its great thickness.

  13. Mitochondrial DNA levels in Huntington disease leukocytes and dermal fibroblasts.

    Science.gov (United States)

    Jędrak, Paulina; Krygier, Magdalena; Tońska, Katarzyna; Drozd, Małgorzata; Kaliszewska, Magdalena; Bartnik, Ewa; Sołtan, Witold; Sitek, Emilia J; Stanisławska-Sachadyn, Anna; Limon, Janusz; Sławek, Jarosław; Węgrzyn, Grzegorz; Barańska, Sylwia

    2017-08-01

    Huntington disease (HD) is an inherited neurodegenerative disorder caused by mutations in the huntingtin gene. Involvement of mitochondrial dysfunctions in, and especially influence of the level of mitochondrial DNA (mtDNA) on, development of this disease is unclear. Here, samples of blood from 84 HD patients and 79 controls, and dermal fibroblasts from 10 HD patients and 9 controls were analysed for mtDNA levels. Although the type of mitochondrial haplogroup had no influence on the mtDNA level, and there was no correlation between mtDNA level in leukocytes in HD patients and various parameters of HD severity, some considerable differences between HD patients and controls were identified. The average mtDNA/nDNA relative copy number was significantly higher in leukocytes, but lower in fibroblasts, of symptomatic HD patients relative to the control group. Moreover, HD women displayed higher mtDNA levels in leukocytes than HD men. Because this is the largest population analysed to date, these results might contribute to explanation of discrepancies between previously published studies concerning levels of mtDNA in cells of HD patients. We suggest that the size of the investigated population and type of cells from which DNA is isolated could significantly affect results of mtDNA copy number estimation in HD. Hence, these parameters should be taken into consideration in studies on mtDNA in HD, and perhaps also in other diseases where mitochondrial dysfunction occurs.

  14. Optical coherence tomography: imaging architect for dermal microdialysis in psoriasis

    Science.gov (United States)

    O'Connell, M.-L.; O'Connor, W.; Ramsay, B.; Guihen, E.; Ho, W. L.; Leahy, M. J.

    2011-03-01

    Optical coherence tomography (OCT) has been used as part of a ground breaking translational study to shed some light on one of the worlds most prevalent autoimmune diseases; psoriasis. The work successfully integrates the fields of optical imaging, biochemistry and dermatology in conducting a dermal microdialysis (DMD) trial for quantitative histamine assessment amongst a group of psoriasis sufferers. The DMD process involves temporary insertion of microscopic hollow tubes into a layer of skin to measure the levels of histamine and other important biological molecules in psoriasis. For comparison purposes, DMD catheters were implanted into healthy, peri-lesional and lesional skin regions. The catheters' entry and exit points and their precise locations in the epidermal layer of the skin were confirmed using OCT thus obtaining high resolution, wide-field images of the affected skin as well as catheter placement whilst local microdialysis enabled a tissue chemistry profile to be obtained from these three skin regions including histamine, a local immune system activator known to contribute towards itch and inflammation. Together these tools offer a synergistic approach in the clinical assessment of the disease. In addition, OCT delivered a non-invasive and rapid method for analyzing the affected skin architecture.

  15. Evaluation of dermal symptoms in hypothyroidism and hyperthyroidism.

    Science.gov (United States)

    Razi, Ahad; Golforoushan, Farideh; Nejad, Amir Bahrami Shahla Babaee; Goldust, Mohamad

    2013-06-01

    Many symptoms arise in thyroid diseases. The aim of this study was to evaluate the dermal symptoms in hypothyroidism and hyperthyroidism. In this cross sectional study, 120 patients with hyperthyroidism and 50 patients suffering from hypothyroidism were studied. Cutaneous, hair and nail clinical symptoms were studied and registered in a special questionnaire. Mean age of patients suffering from hypothyroidism and hyperthyroidism were 38.24 +/- 14.45 and 25.86 +/- 14.69 years old. Dry and Coarse/rough skin were the most prevalent manifestations in the skin involvement in hypothyroidism since softness was the most prevalent ones in hyperthyroidism. Fragileness was the most prevalent symptom in patients with nail involvement in hypothyroidism since soft skin was the most prevalent ones in hyperthyroidism. Coarse/rough skin was observed more in patients with hair involvement in hypothyroidism since the most prevalent ones was separation of nail from its bed in hyperthyroidism. High prevalence of skin, hair and nail symptoms in thyroid patients, early diagnosis of the signs may be helpful in premature diagnosis and treatment of thyroid diseases.

  16. Property of filler-loaded magnetic ferrite from plastic waste bottle used to treat municipal domestic sewage.

    Science.gov (United States)

    Zhao, Ru-Jin; Gong, Li-Ying; Zhu, Hai-Dong; Liu, Qiao; Xu, Li-Xia; Lu, Lu; Yang, Qi-Zhi

    2018-06-01

    The present work investigates the properties of self-made magnetic filler from plastic waste bottle and explores a new technology approach of waste plastic resource utilization. The magnetic filler was prepared by air plasma modification and loading magnetic ferrite on the plastic strip from waste plastic bottle. The surface properties of magnetic filler were characterized by Atomic Force Microscope (AFM), contact angle system and Fourier Transform Infrared (FTIR). AFM images of original and modified plastic strip showed that low-temperature plasma treatment markedly increased the surface roughness of plastic strip. The mean roughness (Ra) of plastic strip rose from 1.116 to 5.024 nm. FTIR spectra indicated that a lot of polar oxygenic groups were introduced onto the surface of plastic by plasma modification. Modification by low-temperature plasma increased the hydrophilicity of plastic strip surface. When treatment time is 40 s, water contact angle of plastic strip surface reduced from 78.2° of original plastic strip to 25.3°. When used in bioreactor, magnetic filler had very favorable microenvironment for microorganism growth. Magnetic filler was more efficient for removing chemical oxygen demand (COD) and [Formula: see text] in sewage than nonmagnetic filler. The resource utilization of plastic wastes will become reality if the magnetic filler is applied widely.

  17. Study of tetrapodal ZnO-PDMS composites: a comparison of fillers shapes in stiffness and hydrophobicity improvements.

    Directory of Open Access Journals (Sweden)

    Xin Jin

    Full Text Available ZnO particles of different size and structures were used as fillers to modify the silicone rubber, in order to reveal the effect of the filler shape in the polymer composites. Tetrapodal shaped microparticles, short microfibers/whiskers, and nanosized spherical particles from ZnO have been used as fillers to fabricate the different ZnO-Silicone composites. The detailed microstructures of the fillers as well as synthesized composites using scanning electron microscopy have been presented here. The tensile elastic modulus and water contact angle, which are important parameters for bio-mimetic applications, of fabricated composites with different fillers have been measured and compared. Among all three types of fillers, tetrapodal shaped ZnO microparticles showed the best performance in terms of increase in hydrophobicity of material cross-section as well as the stiffness of the composites. It has been demonstrated that the tetrapodal shaped microparticles gain their advantage due to the special shape, which avoids agglomeration problems as in the case for nanoparticles, and the difficulty of achieving truly random distribution for whisker fillers.

  18. Study of tetrapodal ZnO-PDMS composites: a comparison of fillers shapes in stiffness and hydrophobicity improvements.

    Science.gov (United States)

    Jin, Xin; Deng, Mao; Kaps, Sören; Zhu, Xinwei; Hölken, Iris; Mess, Kristin; Adelung, Rainer; Mishra, Yogendra Kumar

    2014-01-01

    ZnO particles of different size and structures were used as fillers to modify the silicone rubber, in order to reveal the effect of the filler shape in the polymer composites. Tetrapodal shaped microparticles, short microfibers/whiskers, and nanosized spherical particles from ZnO have been used as fillers to fabricate the different ZnO-Silicone composites. The detailed microstructures of the fillers as well as synthesized composites using scanning electron microscopy have been presented here. The tensile elastic modulus and water contact angle, which are important parameters for bio-mimetic applications, of fabricated composites with different fillers have been measured and compared. Among all three types of fillers, tetrapodal shaped ZnO microparticles showed the best performance in terms of increase in hydrophobicity of material cross-section as well as the stiffness of the composites. It has been demonstrated that the tetrapodal shaped microparticles gain their advantage due to the special shape, which avoids agglomeration problems as in the case for nanoparticles, and the difficulty of achieving truly random distribution for whisker fillers.

  19. Investigation on mechanical properties of welded material under different types of welding filler (shielded metal arc welding)

    Science.gov (United States)

    Tahir, Abdullah Mohd; Lair, Noor Ajian Mohd; Wei, Foo Jun

    2018-05-01

    The Shielded Metal Arc Welding (SMAW) is (or the Stick welding) defined as a welding process, which melts and joins metals with an arc between a welding filler (electrode rod) and the workpieces. The main objective was to study the mechanical properties of welded metal under different types of welding fillers and current for SMAW. This project utilized the Design of Experiment (DOE) by adopting the Full Factorial Design. The independent variables were the types of welding filler and welding current, whereas the other welding parameters were fixed at the optimum value. The levels for types of welding filler were by the models of welding filler (E6013, E7016 and E7018) used and the levels for welding current were 80A and 90A. The responses were the mechanical properties of welded material, which include tensile strength and hardness. The experiment was analyzed using the two way ANOVA. The results prove that there are significant effects of welding filler types and current levels on the tensile strength and hardness of the welded metal. At the same time, the ANOVA results and interaction plot indicate that there are significant interactions between the welding filler types and the welding current on both the hardness and tensile strength of the welded metals, which has never been reported before. This project found that when the amount of heat input with increase, the mechanical properties such as tensile strength and hardness decrease. The optimum tensile strength for welded metal is produced by the welding filler E7016 and the optimum of hardness of welded metal is produced by the welding filler E7018 at welding current of 80A.

  20. Disposition of 2,4-dichlorophenoxyacetic acid dimethylamine by Fischer 344 rats dosed orally and dermally

    International Nuclear Information System (INIS)

    Pelletier, O.; Ritter, L.; Caron, J.; Somers, D.

    1989-01-01

    The dimethylamine salt of 14C-ring-labeled 2,4-D was administered to Fischer 344 rats orally (1 and 0.4 mg/kg body weight) and dermally (10 mg/kg body weight). Absorption, distribution, and elimination were determined from 14C-labeled 2,4-D in blood, tissues, and excreta. Quantitatively, most of the orally administered dose (94-96%) became systemically available within 6 h. Following dermal administration 10% of the dose became systemically available over 72 h. However, peak concentrations in blood and kidneys were achieved within 30 min of dosing by either route. By 1.5 h after dosing, 2,4-D concentrations in blood, muscle, liver, and kidneys had decreased in both the orally dosed and dermally dosed animals. Between 2 and 8 h, the blood, muscle, liver and kidney concentrations in dermally dosed animals maintained a plateau while urinary excretion increased, presumably due to continued absorption of 2,4-D from the skin. The concentrations in orally dosed animals continued to decrease. Following 7 h of dermal exposure, skin cleansing removed about 63% of the applied dose; about 17% of the applied dose remained at the site of dermal dosing. At 8 h, 2,4-D concentrations in blood, muscle, liver, and kidneys of dermally dosed animals began to decrease, most likely a result of the removal of the reservoir on the skin. However, 2,4-D continued to be absorbed from skin site, resulting in a slower decline of the 2,4-D concentrations in these tissues over remainder of the 72-h study period. By comparison, in animals that had been orally dosed, the absorbed dose was almost completely excreted within 24 h

  1. Dermal bioavailability of benzo[a]pyrene on lampblack: implications for risk assessment.

    Science.gov (United States)

    Stroo, Hans F; Roy, Timothy A; Liban, Cris B; Kreitinger, Joseph P

    2005-06-01

    Lampblack is the principal source of contamination in soils at manufactured gas plant (MGP) sites where oil was used as the feedstock. Risks and cleanup criteria at these sites are determined primarily by the total carcinogenic polynuclear aromatic hydrocarbon (PAH) content, particularly the concentration of benzo[a]pyrene (BaP). Dermal contact with soils at oil-gas MGP sites is a significant component of the overall risks. Seven samples were collected from oil-gas MGP sites and the steady-state dermal fluxes were measured over 96 h in vitro. The standard dermal bioassay technique (in which 3H-BaP is added to the soil matrix) was modified to allow direct measurement of the dermal absorption of the native BaP in the samples. The experimentally derived dermal absorption factors for BaP were 14 to 107 times lower than the default assumption of 15% over 24 h (55-fold lower on average). The dermal fluxes were correlated positively to the total BaP and total carbon concentrations. The measured dermal absorption factors were compared to the default risk-assessment calculations for all seven samples. The calculated excess cancer risk was reduced as a result of using the measured absorption factors by 97% on average (with reductions ranging from 93 to 99%). This work indicates the risks at oil-gas MGP sites currently are overestimated by one to two orders of magnitude, and provides a protocol for the testing and data analysis needed to generate site-specific cleanup levels.

  2. SIRT-1 regulates TGF-β-induced dermal fibroblast migration via modulation of Cyr61 expression.

    Science.gov (United States)

    Kwon, Eun-Jeong; Park, Eun-Jung; Yu, Hyeran; Huh, Jung-Sik; Kim, Jinseok; Cho, Moonjae

    2018-05-01

    SIRT1 is a NAD-dependent protein deacetylase that participates in cellular regulation. The increased migration of fibroblasts is an important phenotype in fibroblast activation. The role of SIRT1 in cell migration remains controversial as to whether SIRT1 acts as an activator or suppressor of cell migration. Therefore, we have established the role of SIRT1 in the migration of human dermal fibroblasts and explored targets of SIRT1 during dermal fibroblast migration. SIRT1 and Cyr61 were expressed in human dermal fibroblasts and the stimulation with TGF-β further induced their expression. Treatment with resveratrol (RSV), a SIRT1 agonist, or overexpression of SIRT1 also promoted the expression Cyr61 in human dermal fibroblasts, whereas the inhibition of SIRT1 activity by nicotinamide or knockdown of SIRT1 decreased the level of Cyr61, as well as TGF-β or RSV-induced Cyr61 expression. Blocking of ERK signaling by PD98509 reduced the expression of Cyr61 induced by TGF-β or RSV. TGF-β, RSV, or SIRT1 overexpression enhanced β-catenin as well as Cyr61 expression. This stimulation was reduced by the Wnt inhibitor XAV939. RSV increased migration and nicotinamide attenuated RSV-induced migration of human dermal fibroblasts. Furthermore, SIRT1 overexpression promoted cell migration, whereas blocking Cyr61 attenuated SIRT1-stimulated migration of human dermal fibroblasts. SIRT1 increased cell migration by stimulating Cyr61 expression and the ERK and Wnt/β-catenin signaling. SIRT1-induced Cyr61 activity is very important for human dermal fibroblasts migration.

  3. [Influences of composition on brush wear of composite resins. Influences of particle size and content of filler].

    Science.gov (United States)

    Yuasa, S

    1990-07-01

    The influences of the composition on abrasion resistance of composite resins were examined using various experimental composite resins which had various matrix resin, filler size and content. The abrasion test was conducted by the experimental toothbrush abrasion testing machine developed in our laboratory. Three series of heat-curing composite resins were tested. One series was made from a Bis-MPEPP or UDMA monomer, and a silica filler with an average particle size of 0.04, 1.9, 3.8, 4.3, 7.5, 13.8 and 14.1 microns. The filler content of this series was constant at 45 wt%. The second series contained a silica filler of 4.3 microns in a content ranging from 35 to 75 wt%. The third series contained a microfiller (0.04 microns) and macrofiller (4.3 microns) in total content of 45 wt%. In this series, the microfiller was gradually replaced by 5, 15, 25 and 45 wt% of the macrofiller. The results obtained for these three series indicated that the abrasion resistance of composite resins was controlled by the inorganic filler, mainly filler size and content. The abrasion loss did not vary with the difference of matrix resin. When the particle size of the filler was below about 5 microns, the abrasion resistance decreased markedly with the decrease in filler size. The composite resin which contained a 0.04 or 1.9 micron filler was less resistant to toothbrush wear than the unfilled matrix resin. However, the microfiller also contributed to abrasion resistance when used in combination with the macrofiller, although abrasion resistance decreased with the increase in the microfiller concentration. The increase of filler content clearly improved the abrasion resistance when used the macrofiller. The analysis of these results and SEM observations of the brushed surfaces of samples suggested that the toothbrush abrasion was three-body abrasion caused by the abrasive in the toothpaste, and affected by the difference in the particle size between abrasive and filler, and between

  4. License application design selection feature report: Additive and fillers design feature 19

    International Nuclear Information System (INIS)

    Massari, J.R.

    1999-01-01

    The estimated additional total system life-cycle cost for each of the filler options in 1999 dollars is as follows: $923.4 million for the iron oxide option, $42.4 million to $966.4 million (depending on the extent of surface facility involvement required) for the partial iron shot fill option, $1,012 million for the complete iron shot fill option, and $134.7 million for the integral filler option (Appendix A). All of the filler options evaluated showed improvements in some aspects of pre- and post-closure waste package and repository performance. However, all of the options, except for the integral filler option, negatively impacted other areas of performance, required modification to surface facility design and operations, and invoked additional uncertainty. The iron oxide filler option will require further testing to measure thermal conductivity to ensure that peak cladding temperatures will not exceed the 350 C limit. The complete iron shot fill option may require structural improvements to the waste package design (use of partial shot fill may eliminate this concern). Both the iron shot and iron oxide options will also require further testing to confirm that the conceptual loading strategy will efficiently load a waste package in a timely manner. In addition, both shot and oxide options will require further testing to develop models for their potential to provide resistance to water flow, and, in the case of iron shot, act as an oxygen getter. Finally, uncertainty also exists as to whether the iron shot option will damage the cladding if sufficient corrosion of the shot occurs. Based on the results presented in this evaluation, the integral filler option appears to be the simplest and most cost efficient method for achieving modest improvements in pre- and post-closure performance. Since unqualified inputs were used in the development of this evaluation, they should be considered TBV (to be verified). This document will not directly support any construction

  5. Characterization and assessment of dermal and inhalable nickel exposures in nickel production and primary user industries.

    Science.gov (United States)

    Hughson, G W; Galea, K S; Heim, K E

    2010-01-01

    The aim of this study was to measure the levels of nickel in the skin contaminant layer of workers involved in specific processes and tasks within the primary nickel production and primary nickel user industries. Dermal exposure samples were collected using moist wipes to recover surface contamination from defined areas of skin. These were analysed for soluble and insoluble nickel species. Personal samples of inhalable dust were also collected to determine the corresponding inhalable nickel exposures. The air samples were analysed for total inhalable dust and then for soluble, sulfidic, metallic, and oxidic nickel species. The workplace surveys were carried out in five different workplaces, including three nickel refineries, a stainless steel plant, and a powder metallurgy plant, all of which were located in Europe. Nickel refinery workers involved with electrolytic nickel recovery processes had soluble dermal nickel exposure of 0.34 microg cm(-2) [geometric mean (GM)] to the hands and forearms. The GM of soluble dermal nickel exposure for workers involved in packing nickel salts (nickel chloride hexahydrate, nickel sulphate hexahydrate, and nickel hydroxycarbonate) was 0.61 microg cm(-2). Refinery workers involved in packing nickel metal powders and end-user powder operatives in magnet production had the highest dermal exposure (GM = 2.59 microg cm(-2) soluble nickel). The hands, forearms, face, and neck of these workers all received greater dermal nickel exposure compared with the other jobs included in this study. The soluble nickel dermal exposures for stainless steel production workers were at or slightly above the limit of detection (0.02 microg cm(-2) soluble nickel). The highest inhalable nickel concentrations were observed for the workers involved in nickel powder packing (GM = 0.77 mg m(-3)), although the soluble component comprised only 2% of the total nickel content. The highest airborne soluble nickel exposures were associated with refineries using

  6. Parameter optimization toward optimal microneedle-based dermal vaccination.

    Science.gov (United States)

    van der Maaden, Koen; Varypataki, Eleni Maria; Yu, Huixin; Romeijn, Stefan; Jiskoot, Wim; Bouwstra, Joke

    2014-11-20

    Microneedle-based vaccination has several advantages over vaccination by using conventional hypodermic needles. Microneedles are used to deliver a drug into the skin in a minimally-invasive and potentially pain free manner. Besides, the skin is a potent immune organ that is highly suitable for vaccination. However, there are several factors that influence the penetration ability of the skin by microneedles and the immune responses upon microneedle-based immunization. In this study we assessed several different microneedle arrays for their ability to penetrate ex vivo human skin by using trypan blue and (fluorescently or radioactively labeled) ovalbumin. Next, these different microneedles and several factors, including the dose of ovalbumin, the effect of using an impact-insertion applicator, skin location of microneedle application, and the area of microneedle application, were tested in vivo in mice. The penetration ability and the dose of ovalbumin that is delivered into the skin were shown to be dependent on the use of an applicator and on the microneedle geometry and size of the array. Besides microneedle penetration, the above described factors influenced the immune responses upon microneedle-based vaccination in vivo. It was shown that the ovalbumin-specific antibody responses upon microneedle-based vaccination could be increased up to 12-fold when an impact-insertion applicator was used, up to 8-fold when microneedles were applied over a larger surface area, and up to 36-fold dependent on the location of microneedle application. Therefore, these influencing factors should be considered to optimize microneedle-based dermal immunization technologies. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. A systematic review of acelluar dermal matrices in head and neck reconstruction.

    Science.gov (United States)

    Shridharani, Sachin M; Tufaro, Anthony P

    2012-11-01

    The use of acellular dermal matrices has been well described in the scientific literature since the early 1990 s and has been utilized for multiple applications in the head and neck for both aesthetic and reconstructive efforts. After systematically searching the PubMed database and following further refinement (based on the authors' inclusion and exclusion criteria), the authors identified 30 studies that provided information about patients who had undergone head and neck reconstruction with the use of acellular dermal matrix. Studies had to report quantifiable objective results in patients who were older than 1 year and younger than 90 years. The authors excluded single case reports, studies with fewer than 10 patients, and studies not published in English. The optimal material used as an implant for reconstruction possesses the following properties: facilitation of vascular ingrowth, decreased propensity to incite inflammation, biologic inertness, resistance to infection, and ease of handling. Acellular dermal matrix possesses many of these properties and is utilized in reconstructing nasal soft tissue and skeletal support, tympanic membrane, periorbital soft tissue, extraoral and intraoral defects, oropharyngeal defects, dura mater, and soft-tissue deficits from parotidectomy. Furthermore, it is used to assist in preventing Frey syndrome following parotidectomy and surgical treatment of facial paralysis. Use of acellular dermal matrix for head and neck reconstruction has expanded exponentially and is validated in many studies. Further prospective randomized control trials are warranted to further investigate the efficacy of acellular dermal matrix in head and neck reconstruction.

  8. A Bayesian statistical analysis of mouse dermal tumor promotion assay data for evaluating cigarette smoke condensate.

    Science.gov (United States)

    Kathman, Steven J; Potts, Ryan J; Ayres, Paul H; Harp, Paul R; Wilson, Cody L; Garner, Charles D

    2010-10-01

    The mouse dermal assay has long been used to assess the dermal tumorigenicity of cigarette smoke condensate (CSC). This mouse skin model has been developed for use in carcinogenicity testing utilizing the SENCAR mouse as the standard strain. Though the model has limitations, it remains as the most relevant method available to study the dermal tumor promoting potential of mainstream cigarette smoke. In the typical SENCAR mouse CSC bioassay, CSC is applied for 29 weeks following the application of a tumor initiator such as 7,12-dimethylbenz[a]anthracene (DMBA). Several endpoints are considered for analysis including: the percentage of animals with at least one mass, latency, and number of masses per animal. In this paper, a relatively straightforward analytic model and procedure is presented for analyzing the time course of the incidence of masses. The procedure considered here takes advantage of Bayesian statistical techniques, which provide powerful methods for model fitting and simulation. Two datasets are analyzed to illustrate how the model fits the data, how well the model may perform in predicting data from such trials, and how the model may be used as a decision tool when comparing the dermal tumorigenicity of cigarette smoke condensate from multiple cigarette types. The analysis presented here was developed as a statistical decision tool for differentiating between two or more prototype products based on the dermal tumorigenicity. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  9. Investigation of Friction Behaviors of Brake Shoe Materials using Metallic Filler

    Directory of Open Access Journals (Sweden)

    E. Surojo

    2015-12-01

    Full Text Available Some vehicles use brake shoe made from semi-metallic materials. Semi-metallic brake shoes are made from a combination of metallic and non-metallic materials. Metallic particles are added in the formulation of brake shoe material to improve composites characteristics. In this paper, friction behaviors of brake shoe material using metallic filler were investigated. Machining chips of cast iron and copper wire of electric motor used were incorporated in composite as metallic fillers with amount 0, 2, and 4 vol. %. Friction testing was performed to measure coefficient of friction by pressing surface specimen against the surface of rotating disc. The results show that cast iron chip and Cu short wire have effect on increasing coefficient of friction of brake shoe material. They form contact plateau at contact surface. At contact surface, the Cu short wires which have parallel orientation to the sliding contact were susceptible to detach from the matrix.

  10. Magnetic and physical-mechanical properties of polymer composites with soft magnetic fillers

    International Nuclear Information System (INIS)

    Usakova, M.; Usak, E.; Olah, V.; Rekosova, J.

    2013-01-01

    In this paper the influence of soft magnetic ferrite fillers on magnetic and physical-mechanical properties of the prepared composite samples based in natural rubber matrix was studied. The soft magnetic ferrite materials with the chemical composition Mn_0_._3_7Zn_0_._5_7Fe_2_._0_6O_4 and Ni_0_._3_3Zn_0_._6_7Fe_2O_4 were used as magnetic filler in various concentrations. Further, the effect of thermo-oxidative ageing on the prepared composite materials was investigated. Magneto-rheological elastomers are solid analogues to magneto-rheological fluids. These materials are considered as smart materials comprising of micro- or submicro-sized magnetic particles dispersed in non-magnetic matrix. (authors)

  11. Electrical properties of alkali-activated slag composite with combined graphite/CNT filler

    Science.gov (United States)

    Rovnaník, P.; Míková, M.; Kusák, I.

    2017-10-01

    Alkali-activated industrial by-products such as blast furnace slag are known to possess properties which are comparable to or even better than those observed for ordinary Portland cement. The combination of alkali-activated slag matrix with conductive filler introduces new functionalities which are commonly known for self-sensing or self-heating concrete. The present paper discusses the effect of the mixture of two different conductive fillers, graphite powder and carbon nanotubes (CNTs), on the electrical properties of alkali-activated slag mortars. Prepared samples were also tested for their mechanical properties and microstructure was investigated by means of mercury intrusion porosimetry and scanning electron microscopy. The percolation threshold for the resistance was reached for the mixture containing 0.1% CNTs and 8% graphite powder.

  12. Preparation of nanocrystalline iron-carbon materials as fillers for polymers

    International Nuclear Information System (INIS)

    Narkiewicz, U; Pelech, I; Roslaniec, Z; Kwiatkowska, M; Arabczyk, W

    2007-01-01

    This paper presents a method of preparing nanocrystalline iron-carbon materials which can be applied as fillers for polymers. Nanocrystalline iron samples were carburized either under ethylene/hydrogen mixture or under pure ethylene. Three kinds of samples were prepared: cementite/carbon (Fe 3 C/C), iron/cementite (Fe/Fe 3 C) and iron/carbon (Fe/C) ones. After carburization the samples were characterized using XRD and SEM methods. The obtained samples of iron-carbon nanoparticles were applied as fillers to polymer nanocomposites prepared in a polycondensation reaction (in situ) in a poly(ether-ester) matrix. The nanofillers were dispersed in monomers (diols) using a sonificator and a high-speed rotary stirrer. The obtained nanocomposites were characterized as regards their structure (SEM method) and mechanical behaviour

  13. Processing of oil palm empty fruit bunch as filler material of polymer recycles

    Science.gov (United States)

    Saepulloh, D. R.; Nikmatin, S.; Hardhienata, H.

    2017-05-01

    Oil palm empty fruit bunches (OPEFB) is waste from crude palm oil (CPO) processing plants. This research aims to process OPEFB to be a reinforcement polymer recycle with the mechanical milling method and identify each establishment molecular with the orbital hybridization theory. OPEFB fibers were synthesized using a mechanical milling until the size shortfiber and microfiber. Then do the biocomposite granular synthesis with single screw extruder. TAPPI chemical test shows levels of α-cellulose fibers amounted 41.68%. Based on density, the most optimum composition contained in the filler amounted 15% with the size is the microfiber. The test results of morphology with SEM showed deployment of filler OPEFB fiber is fairly equitable distributed. Regarding the molecular interaction between matrix with OPEFB fiber, described by the theory of orbital hybridization. But the explanation establishment of the bond for more complex molecules likes this from the side of the molecular orbital theory is necessary complete information of the hybrid levels.

  14. Hybrid 2D-3D modelling of GTA welding with filler wire addition

    KAUST Repository

    Traidia, Abderrazak

    2012-07-01

    A hybrid 2D-3D model for the numerical simulation of Gas Tungsten Arc welding is proposed in this paper. It offers the possibility to predict the temperature field as well as the shape of the solidified weld joint for different operating parameters, with relatively good accuracy and reasonable computational cost. Also, an original approach to simulate the effect of immersing a cold filler wire in the weld pool is presented. The simulation results reveal two important observations. First, the weld pool depth is locally decreased in the presence of filler metal, which is due to the energy absorption by the cold feeding wire from the hot molten pool. In addition, the weld shape, maximum temperature and thermal cycles in the workpiece are relatively well predicted even when a 2D model for the arc plasma region is used. © 2012 Elsevier Ltd. All rights reserved.

  15. Structure and performance of polymer-derived bulk ceramics determined by method of filler incorporation

    Science.gov (United States)

    Konegger, T.; Schneider, P.; Bauer, V.; Amsüss, A.; Liersch, A.

    2013-12-01

    The effect of four distinct methods of incorporating fillers into a preceramic polymer matrix was investigated with respect to the structural and mechanical properties of the resulting materials. Investigations were conducted with a polysiloxane/Al2O3/ZrO2 model system used as a precursor for mullite/ZrO2 composites. A quantitative evaluation of the uniformity of filler distribution was obtained by employing a novel image analysis. While solvent-free mixing led to a heterogeneous distribution of constituents resulting in limited mechanical property values, a strong improvement of material homogeneity and properties was obtained by using solvent-assisted methods. The results demonstrate the importance of the processing route on final characteristics of polymer-derived ceramics.

  16. Composite adhesive bonds reinforced with microparticle filler based on egg shell waste

    Science.gov (United States)

    Müller, Miroslav; Valášek, Petr

    2018-05-01

    A research on composite adhesive bonds reinforced with waste from hen eggs processing, i.e. egg shell waste (ESW) is based on an assumption of the utilization of agricultural/food production waste. The aim of the research is to gain new pieces of knowledge about the material utilization of ESW, i.e. to evaluate possibilities of the use of various concentrations of ESW microparticles smaller than 100 µm based on hen egg shells as the filler in a structural resin used for a creation of adhesive bonds from bearing metal elements. An adhesive bond strength, an elongation at break and a fracture surface were evaluated within the research on adhesive bonds. The experiment results proved the efficiency of ESW filler in the area of composite adhesive bonds. The adhesive bond strength was increased up of more than 17 % by adding 40 wt.% of ESW microparticles.

  17. The effects of fillers on polyurethane resin-based electrical insulators

    Directory of Open Access Journals (Sweden)

    Altafim Ruy Alberto Corrêa

    2003-01-01

    Full Text Available The increasingly widespread use of polymeric insulators in vehicle distributors and transmission systems has led to an ongoing quest for quality and low costs. This quest has, in turn, resulted in improved performance and cost benefits, brought about by the use of new polymeric and composite resins. Occasionally, however, while some properties are improved, others may show a loss of optimal performance. Therefore, to understand the behavior of fillers, such as carbon black, silica and mica added to castor oil-derived polyurethane resins, several thermal, mechanical and electrical tests were conducted on samples and insulators produced specifically for this purpose, using these new materials. The results of these tests clearly demonstrated that this type of resin and its composites can be used to manufacture indoor electrical insulators and that the fillers analyzed in this study improve or maintain the characteristics of the pure resins.

  18. Study of the Mechanical and Morphology Properties of Recycled HDPE Composite Using Rice Husk Filler

    Directory of Open Access Journals (Sweden)

    Jia Ying Tong

    2014-01-01

    Full Text Available WPCs are being used in a large number of applications in the automotive, construction, electronic, and aerospace industries. There are an increasing number of research studies and developments in WPC technology involving rice husk as fillers. This study investigated the effects of different compositions of rice husk (RH filler on the mechanical and morphological properties of recycled HDPE (rHDPE composite. The composites were prepared with five different loading contents of RH fibers (0, 10, 20, 30, and 40 wt% using the twin screw extrusion method. Maleic acid polyethylene (MAPE was added as a coupling agent. Results showed that tensile and flexural properties improved with increasing RH loading. However, the impact strength of the composites decreased as the RH loading increased. SEM micrographs revealed good interfacial bonding between the fiber and polymer matrix.

  19. Properties of natural rubber/attapulgite composites prepared by latex compounding method: Effect of filler loading

    International Nuclear Information System (INIS)

    Muttalib, Siti Nadzirah Abdul; Othman, Nadras; Ismail, Hanafi

    2015-01-01

    This paper reports on the effect of filler loading on properties of natural rubber (NR)/attapulgite (ATP) composites. The NR/ATP composites were prepared by latex compounding method. It is called as masterbatch. The masterbatch was subsequently added to the NR through melt mixing process. The vulcanized NR/ATP composites were subjected to mechanical, swelling and morphological tests. All the results were compared with NR/ATP composites prepared by conventional system. The composites from masterbatch method showed better results compared to composites prepared by conventional method. They have higher tensile properties, elongation at break and tear strength. The images captured through scanning electron microscopy test revealed the improvement of tensile strength in masterbatch NR/ATP composites. It can be seen clearly that masterbatch NR/ATP have better filler dispersion compared to conventional method NR/ATP composites

  20. Properties of natural rubber/attapulgite composites prepared by latex compounding method: Effect of filler loading

    Energy Technology Data Exchange (ETDEWEB)

    Muttalib, Siti Nadzirah Abdul, E-mail: sitinadzirah.amn@gmail.com; Othman, Nadras, E-mail: srnadras@usm.my; Ismail, Hanafi, E-mail: ihanafi@usm.my [School of Materials and Mineral Resources Engineering, Engineering Campus, Universiti Sains Malaysia, Seri Ampangan, 14300 Nibong Tebal, Pulau Pinang (Malaysia)

    2015-07-22

    This paper reports on the effect of filler loading on properties of natural rubber (NR)/attapulgite (ATP) composites. The NR/ATP composites were prepared by latex compounding method. It is called as masterbatch. The masterbatch was subsequently added to the NR through melt mixing process. The vulcanized NR/ATP composites were subjected to mechanical, swelling and morphological tests. All the results were compared with NR/ATP composites prepared by conventional system. The composites from masterbatch method showed better results compared to composites prepared by conventional method. They have higher tensile properties, elongation at break and tear strength. The images captured through scanning electron microscopy test revealed the improvement of tensile strength in masterbatch NR/ATP composites. It can be seen clearly that masterbatch NR/ATP have better filler dispersion compared to conventional method NR/ATP composites.