WorldWideScience

Sample records for hydraulically self-actuating clamp

  1. Analysis for Clamping Force of Hydraulic Slide-valve Spool Based on Fluent%基于Fluent的液压滑阀阀芯卡紧力研究

    Institute of Scientific and Technical Information of China (English)

    陈奎生; 周雯娟; 郭媛; 付曙光; 张宏伟; 蒋俊

    2011-01-01

    Through simulation and analysis, the changes in clamping force of the hydraulic slide-valve spool when the spool skewed were studied, with no pressure-equalizing grooves, three rectangular grooves, five rectangular grooves and five triangular grooves. The simulation results show; opening pressure-equalizing grooves in the valve can reduce clamping force; the more pressure equalizing grooves open, the smaller the clamping force becomes. With the same amount, clamping force of spool with rectangular grooves is larger than that with triangle grooves, but the spool with rectangular grooves is more conducive to become concentric.%通过仿真分析,研究液压滑阀阀芯在不开均压槽、开3条矩形槽、开5条矩形槽、开5条三角形槽4种情况下,阀芯歪斜时阀芯卡紧力的变化.由仿真结果可知:阀芯歪斜时,在阀芯上开均压槽可以有效减小卡紧力,开的均压槽越多,卡紧力越小;开相同数量的矩形槽比三角槽的卡紧力大,但是更利于使阀芯趋于同心.

  2. Reversible Self-Actuated Thermo-Responsive Pore Membrane

    Science.gov (United States)

    Park, Younggeun; Gutierrez, Maria Paz; Lee, Luke P.

    2016-12-01

    Smart membranes, which can selectively control the transfer of light, air, humidity and temperature, are important to achieve indoor climate regulation. Even though reversible self-actuation of smart membranes is desirable in large-scale, reversible self-regulation remains challenging. Specifically, reversible 100% opening/closing of pore actuation showing accurate responsiveness, reproducibility and structural flexibility, including uniform structure assembly, is currently very difficult. Here, we report a reversible, thermo-responsive self-activated pore membrane that achieves opening and closing of pores. The reversible, self-actuated thermo-responsive pore membrane was fabricated with hybrid materials of poly (N-isopropylacrylamide), (PNIPAM) within polytetrafluoroethylene (PTFE) to form a multi-dimensional pore array. Using Multiphysics simulation of heat transfer and structural mechanics based on finite element analysis, we demonstrated that pore opening and closing dynamics can be self-activated at environmentally relevant temperatures. Temperature cycle characterizations of the pore structure revealed 100% opening ratio at T = 40 °C and 0% opening ratio at T = 20 °C. The flexibility of the membrane showed an accurate temperature-responsive function at a maximum bending angle of 45°. Addressing the importance of self-regulation, this reversible self-actuated thermo-responsive pore membrane will advance the development of future large-scale smart membranes needed for sustainable indoor climate control.

  3. Reversible Self-Actuated Thermo-Responsive Pore Membrane.

    Science.gov (United States)

    Park, Younggeun; Gutierrez, Maria Paz; Lee, Luke P

    2016-12-19

    Smart membranes, which can selectively control the transfer of light, air, humidity and temperature, are important to achieve indoor climate regulation. Even though reversible self-actuation of smart membranes is desirable in large-scale, reversible self-regulation remains challenging. Specifically, reversible 100% opening/closing of pore actuation showing accurate responsiveness, reproducibility and structural flexibility, including uniform structure assembly, is currently very difficult. Here, we report a reversible, thermo-responsive self-activated pore membrane that achieves opening and closing of pores. The reversible, self-actuated thermo-responsive pore membrane was fabricated with hybrid materials of poly (N-isopropylacrylamide), (PNIPAM) within polytetrafluoroethylene (PTFE) to form a multi-dimensional pore array. Using Multiphysics simulation of heat transfer and structural mechanics based on finite element analysis, we demonstrated that pore opening and closing dynamics can be self-activated at environmentally relevant temperatures. Temperature cycle characterizations of the pore structure revealed 100% opening ratio at T = 40 °C and 0% opening ratio at T = 20 °C. The flexibility of the membrane showed an accurate temperature-responsive function at a maximum bending angle of 45°. Addressing the importance of self-regulation, this reversible self-actuated thermo-responsive pore membrane will advance the development of future large-scale smart membranes needed for sustainable indoor climate control.

  4. Hydraulics.

    Science.gov (United States)

    Decker, Robert L.; Kirby, Klane

    This curriculum guide contains a course in hydraulics to train entry-level workers for automotive mechanics and other fields that utilize hydraulics. The module contains 14 instructional units that cover the following topics: (1) introduction to hydraulics; (2) fundamentals of hydraulics; (3) reservoirs; (4) lines, fittings, and couplers; (5)…

  5. Energy-harvesting & self-actuated textiles for the home

    DEFF Research Database (Denmark)

    Mossé, Aurélie

    2010-01-01

    the context of rising sustainable design agendas, the role and influence of new materials and technologies on the conceptualization and making of responsive textiles. Exploring the intersection between textiles, architecture and smart technologies, this on-going research aims to map out new design territories...... for smart textiles by questioning how they can be implemented within a domestic context to encourage more resilient environments. More specifically investigating the potential of energyharvesting & self-actuated textiles, the project hopes to highlight new ways for thinking the home as a more permeable...

  6. Analysis of The Clamping Force for 2D Electro-hydraulic Rotary Valve%2D电液转阀式换向阀阀芯卡紧力分析

    Institute of Scientific and Technical Information of China (English)

    童成伟; 阮健; 孔晨菁; 刘奎

    2016-01-01

    Introduces the working principle of 2D electro-hydraulic rotary valve, and puts forward a design scheme of 2D electro-ydraulic rotary valve.Based on the principle of gap flow and analysis of the radial clamping force of the spool of 2D electro-hydraulic rotary valve un-der eccentric conditions,the theoretical calculation formula of the clamping force of the spool is obtained.Using MATLAB software to draw the relationship of spool radial clamping force with eccentric angle and the angle of high and low pressure groove.%介绍了2D电液转阀式换向阀的工作原理,提出了一种2D电液转阀式换向阀的设计方案;应用缝隙流动原理,对2D电液转阀式换向阀阀芯在偏心情况下的径向卡紧力进行系统理论分析,得到阀芯液压卡紧力的理论计算公式;运用MATLAB软件进行数值计算,得出阀芯径向卡紧力与偏心角位置和高低压槽口夹角的关系。

  7. 构架加工通用液压自动夹紧工装的研制与应用%Development and Application of Universal Hydraulic Automatic Clamping Fixture for Frame Machining

    Institute of Scientific and Technical Information of China (English)

    鲍凯; 裴龙洋; 谢莹莹; 沙恒辉; 汪海华

    2015-01-01

    This paper is to decribe the universal hydraulic automatic clamping fixture applicable for frame machining aganist the problems such as current fixtures are lack of universality and uneven clamping force due to manual clamping, and introduce the integral structure design, operation principle and exact application of this fixture. This type of fixture can be used for machining of all types of bogie frame of CSR Puzhen, and this fixture features simple procedure and stable clamping force, which has high value of application and promotion.%针对目前构架加工工装缺乏通用性以及人工夹紧带来的夹紧力不均衡等问题,研制出适用于构架加工通用的液压自动夹紧工装,介绍了该工装的整体结构设计、工作原理和具体应用,该工装可应用于公司所有类型转向架构架的加工,同时具有装夹过程简单、夹紧力稳定等优点,具有较高的应用和推广价值。

  8. Clamp wins pipe repair prize

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2001-04-01

    This paper describes the permanent pipeline repair system, developed by Tekmar, which is powered by seawater hydraulics and is easily installed and tested by any workclass remotely operated vehicle (rov). Details are given of the two main components of the system, namely, the diverless high pressure split repair clamp and the rov-operated tool to install it.

  9. Development of a Wave Energy -Responsive Self-Actuated Blade Articulation Mechanism for an OWC Turbine

    Energy Technology Data Exchange (ETDEWEB)

    Francis A. Di Bella

    2010-06-01

    The Phase I SBIR effort completed the feasibility design, fabrication, and wind tunnel testing of a self-actuated blade articulation mechanism that uses a torsion bar and a lightweight airfoil to affect the articulation of the Wells airfoil. The articulation is affected only by the air stream incident on the airfoil. The self-actuating blade eliminates the complex and costly linkage mechanism that is now needed to perform this function on either a variable pitch Wells-type or Dennis-Auld air turbine. Using the results reported by independent researchers, the projected improvement in the Wells-type turbine efficiency is 20-40%, in addition to an increase in the operating air flow range by 50-100%, therefore enabling a smaller or slower single turbine to be used.

  10. A revised and unified pressure-clamp/relaxation theory for studying plant cell water relations with pressure probes: in-situ determination of cell volume for calculation of volumetric elastic modulus and hydraulic conductivity.

    Science.gov (United States)

    Knipfer, T; Fei, J; Gambetta, G A; Shackel, K A; Matthews, M A

    2014-10-21

    The cell-pressure-probe is a unique tool to study plant water relations in-situ. Inaccuracy in the estimation of cell volume (νo) is the major source of error in the calculation of both cell volumetric elastic modulus (ε) and cell hydraulic conductivity (Lp). Estimates of νo and Lp can be obtained with the pressure-clamp (PC) and pressure-relaxation (PR) methods. In theory, both methods should result in comparable νo and Lp estimates, but this has not been the case. In this study, the existing νo-theories for PC and PR methods were reviewed and clarified. A revised νo-theory was developed that is equally valid for the PC and PR methods. The revised theory was used to determine νo for two extreme scenarios of solute mixing between the experimental cell and sap in the pressure probe microcapillary. Using a fully automated cell-pressure-probe (ACPP) on leaf epidermal cells of Tradescantia virginiana, the validity of the revised theory was tested with experimental data. Calculated νo values from both methods were in the range of optically determined νo (=1.1-5.0nL) for T. virginiana. However, the PC method produced a systematically lower (21%) calculated νo compared to the PR method. Effects of solute mixing could only explain a potential error in calculated νo of cell turgor) of 19%, which is a fundamental parameter in calculating νo. It followed from the revised theory that the ratio of ΔV/ΔP was inversely related to the solute reflection coefficient. This highlighted that treating the experimental cell as an ideal osmometer in both methods is potentially not correct. Effects of non-ideal osmotic behavior by transmembrane solute movement may be minimized in the PR as compared to the PC method.

  11. Hydrodynamics of a self-actuated bacterial carpet using microscale particle image velocimetry.

    Science.gov (United States)

    Kim, Hoyeon; Cheang, U Kei; Kim, Dalhyung; Ali, Jamel; Kim, Min Jun

    2015-03-01

    Microorganisms can effectively generate propulsive force at the microscale where viscous forces overwhelmingly dominate inertia forces; bacteria achieve this task through flagellar motion. When swarming bacteria, cultured on agar plates, are blotted onto the surface of a microfabricated structure, a monolayer of bacteria forms what is termed a "bacterial carpet," which generates strong flows due to the combined motion of their freely rotating flagella. Furthermore, when the bacterial carpet coated microstructure is released into a low Reynolds number fluidic environment, the propulsive force of the bacterial carpet is able to give the microstructure motility. In our previous investigations, we demonstrated motion control of these bacteria powered microbiorobots (MBRs). Without any external stimuli, MBRs display natural rotational and translational movements on their own; this MBR self-actuation is due to the coordination of flagella. Here, we investigate the flow fields generated by bacterial carpets, and compare this flow to the flow fields observed in the bulk fluid at a series of locations above the bacterial carpet. Using microscale particle image velocimetry, we characterize the flow fields generated from the bacterial carpets of MBRs in an effort to understand their propulsive flow, as well as the resulting pattern of flagella driven self-actuated motion. Comparing the velocities between the bacterial carpets on fixed and untethered MBRs, it was found that flow velocities near the surface of the microstructure were strongest, and at distances far above, the surface flow velocities were much smaller.

  12. To clamp or not to clamp late?

    Directory of Open Access Journals (Sweden)

    Nicoletta Iacovidou

    2013-04-01

    Full Text Available When resuscitating a neonate, one encounters controversial issues and a great deal of confusion. These issues include the question as to when should the umbilical cord be clamped. Clamping and cutting the umbilical cord at birth is the oldest intervention in humans. Even though many aspects of the timing for cord clamping have been clarified, some questions still remain unanswered. If delayed cord clamping is to become a standard approach which timing is the optimal? And depending on the mode of delivery should timing be the same or different for normal vaginal delivery or for caesarean section? What about  the compromised neonate, or the very preterm one? We have more questions than answers. More randomized controlled studies are needed in normal and pathologic neonates, in order to address these questions, before we practice delayed cord clamping with safety for the babies and the mothers.

  13. Photovoltaic panel clamp

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Malcolm P.; Mittan, Margaret Birmingham; Miros, Robert H. J.; Stancel, Robert

    2013-03-19

    A photovoltaic panel clamp includes an upper and lower section. The interface between the assembled clamp halves and the module edge is filled by a flexible gasket material, such as EPDM rubber. The gasket preferably has small, finger like protrusions that allow for easy insertion onto the module edge while being reversed makes it more difficult to remove them from the module once installed. The clamp includes mounting posts or an integral axle to engage a bracket. The clamp also may include a locking tongue to secure the clamp to a bracket.

  14. Photovoltaic panel clamp

    Science.gov (United States)

    Mittan, Margaret Birmingham; Miros, Robert H. J.; Brown, Malcolm P.; Stancel, Robert

    2012-06-05

    A photovoltaic panel clamp includes an upper and lower section. The interface between the assembled clamp halves and the module edge is filled by a flexible gasket material, such as EPDM rubber. The gasket preferably has small, finger like protrusions that allow for easy insertion onto the module edge while being reversed makes it more difficult to remove them from the module once installed. The clamp includes mounting posts or an integral axle to engage a bracket. The clamp also may include a locking tongue to secure the clamp to a bracket.

  15. Determination of Liquid Density and Viscosity Using a Self-Actuating Microcantilever

    Science.gov (United States)

    Hur, Don; Lee, Jeong Hoon

    2013-05-01

    A sensor for determining liquid density and viscosity using a self-actuating microcantilever is proposed. A microcantilever incorporating piezoelectric thin films with seven multilayers was fabricated in order to acquire a direct electrical signal. As proof of the operating principle and sensitivity, the change in resonant frequency peak (fres) and full width at half maximum (FWHM; Δf) values with liquid viscosity and density were we measured using the glycerol-water solutions with various glycerol concentrations. With increasing liquid viscosity from 1 to 600 cP, an increase in FWHM from 2920 to 10314 Hz was observed. Also, it was observed that shifts in the resonant frequency decreased with increasing liquid density. Using nonlinear regression fitting between liquid density and fres2, the presented self-sensing microcantilever could potentially provide a solid platform for real-time monitoring of liquid density.

  16. Recent performance experience with US light water reactor self-actuating safety and relief valves

    Energy Technology Data Exchange (ETDEWEB)

    Hammer, C.G.

    1996-12-01

    Over the past several years, there have been a number of operating reactor events involving performance of primary and secondary safety and relief valves in U.S. Light Water Reactors. There are several different types of safety and relief valves installed for overpressure protection of various safety systems throughout a typical nuclear power plant. The following discussion is limited to those valves in the reactor coolant systems (RCS) and main steam systems of pressurized water reactors (PWR) and in the RCS of boiling water reactors (BWR), all of which are self-actuating having a setpoint controlled by a spring-loaded disk acting against system fluid pressure. The following discussion relates some of the significant recent experience involving operating reactor events or various testing data. Some of the more unusual and interesting operating events or test data involving some of these designs are included, in addition to some involving a number of similar events and those which have generic applicability.

  17. Radial wedge flange clamp

    Science.gov (United States)

    Smith, Karl H.

    2002-01-01

    A radial wedge flange clamp comprising a pair of flanges each comprising a plurality of peripheral flat wedge facets having flat wedge surfaces and opposed and mating flat surfaces attached to or otherwise engaged with two elements to be joined and including a series of generally U-shaped wedge clamps each having flat wedge interior surfaces and engaging one pair of said peripheral flat wedge facets. Each of said generally U-shaped wedge clamps has in its opposing extremities apertures for the tangential insertion of bolts to apply uniform radial force to said wedge clamps when assembled about said wedge segments.

  18. Self-actuated shutdown system for a commercial size LMFBR. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Dupen, C.F.G.

    1978-08-01

    A Self-Actuated Shutdown System (SASS) is defined as a reactor shutdown system in which sensors, release mechanisms and neutron absorbers are contained entirely within the reactor core structure, where they respond inherently to abnormal local process conditions, by shutting down the reactor, independently of the plant protection system (PPS). It is argued that a SASS, having a response time similar to that of the PPS, would so reduce the already very low probability of a failure-to-scram event that costly design features, derived from core disruptive accident analysis, could be eliminated. However, the thrust of the report is the feasibility and reliability of the in-core SASS hardware to achieve sufficiently rapid shutdown. A number of transient overpower and transient undercooling-responsive systems were investigated leading to the selection of a primary candidate and a backup concept. During a transient undercooling event, the recommended device is triggered by the associated rate of change of pressure, whereas the alternate concept responds to the reduction in core pressure drop and requires calibration and adjustment by the operators to accommodate changes in reactor power.

  19. Management of umbilical cord clamping.

    Science.gov (United States)

    Webbon, Lucy

    2013-02-01

    The Royal College of Midwives (RCM) has updated its third stage of labour guidelines (RCM 2012) to be clearly supportive of a delay in umbilical cord clamping, although specific guidance on timing is yet to be announced. It is therefore imperative that both midwives and student midwives understand and are able to integrate delaying into their practice, as well as communicating to women the benefits; only in this way can we give women fully informed choices on this aspect of care. The main benefit of delayed cord clamping is the protection it can provide in reducing childhood anaemia, which is a major issue, especially in poorer countries. A review of the evidence found no risks linked to delayed clamping, and no evidence that it cannot be used in combination with the administration of uterotonic drugs. Delayed cord clamping can be especially beneficial for pre term and compromised babies.

  20. Hydraulically Driven Grips For Hot Tensile Specimens

    Science.gov (United States)

    Bird, R. Keith; Johnson, George W.

    1994-01-01

    Pair of grips for tensile and compressive test specimens operate at temperatures up to 1,500 degrees F. Grips include wedges holding specimen inside furnace, where heated to uniform temperature. Hydraulic pistons drive wedges, causing them to exert clamping force. Hydraulic pistons and hydraulic fluid remain outside furnace, at room temperature. Cooling water flows through parts of grips to reduce heat transferred to external components. Advantages over older devices for gripping specimens in high-temperature tests; no need to drill holes in specimens, maintains constant gripping force on specimens, and heated to same temperature as that of specimen without risk of heating hydraulic fluid and acuator components.

  1. Robotic Partial Nephrectomy Using Robotic Bulldog Clamps

    OpenAIRE

    2011-01-01

    Background and Objectives: The need for a skilled assistant to perform hilar clamping during robotic partial nephrectomy is a potential limitation of the technique. We describe our experience using robotic bulldog clamps applied by the console surgeon for hilar clamping. Methods: A total of 60 consecutive patients underwent robotic partial nephrectomy, 30 using laparoscopic bulldog clamps applied by the assistant and 30 using robotic bulldog clamps applied with the robotic Prograsp instrument...

  2. Automated planar patch-clamp.

    Science.gov (United States)

    Milligan, Carol J; Möller, Clemens

    2013-01-01

    Ion channels are integral membrane proteins that regulate the flow of ions across the plasma membrane and the membranes of intracellular organelles of both excitable and non-excitable cells. Ion channels are vital to a wide variety of biological processes and are prominent components of the nervous system and cardiovascular system, as well as controlling many metabolic functions. Furthermore, ion channels are known to be involved in many disease states and as such have become popular therapeutic targets. For many years now manual patch-clamping has been regarded as one of the best approaches for assaying ion channel function, through direct measurement of ion flow across these membrane proteins. Over the last decade there have been many remarkable breakthroughs in the development of technologies enabling the study of ion channels. One of these breakthroughs is the development of automated planar patch-clamp technology. Automated platforms have demonstrated the ability to generate high-quality data with high throughput capabilities, at great efficiency and reliability. Additional features such as simultaneous intracellular and extracellular perfusion of the cell membrane, current clamp operation, fast compound application, an increasing rate of parallelization, and more recently temperature control have been introduced. Furthermore, in addition to the well-established studies of over-expressed ion channel proteins in cell lines, new generations of planar patch-clamp systems have enabled successful studies of native and primary mammalian cells. This technology is becoming increasingly popular and extensively used both within areas of drug discovery as well as academic research. Many platforms have been developed including NPC-16 Patchliner(®) and SyncroPatch(®) 96 (Nanion Technologies GmbH, Munich), CytoPatch™ (Cytocentrics AG, Rostock), PatchXpress(®) 7000A, IonWorks(®) Quattro and IonWorks Barracuda™, (Molecular Devices, LLC); Dynaflow(®) HT (Cellectricon

  3. Multifrequency Excitation of a Clamped-Clamped Microbeam

    KAUST Repository

    Jaber, Nizar R.

    2016-01-20

    We present analytical and experimental investigation of an electrically actuated clamped-clamped microbeam under a twosource harmonic excitation. The first frequency is swept around the first mode of vibration where the second one is fixed. These microbeams are fabricated using polyimide as structural layer coated with nickel form top and chromium and gold layers from bottom. We demonstrate the excitation of additive and subtractive type resonance. We show that by properly tuning the frequency and the amplitude of the excitation force, the frequency bandwidth of the resonator is increased. Theoretically, we solved the eigenvalue problem for different axial forces to find the natural frequencies ratio that match the experimental values. Using Galerkin method, a reduced order model is derived to simulate the static and dynamic response of the device where using three symmetric mode shapes provided a good agreement with experimental data. © Copyright 2015 by ASME.

  4. Hydraulic structures

    CERN Document Server

    Chen, Sheng-Hong

    2015-01-01

    This book discusses in detail the planning, design, construction and management of hydraulic structures, covering dams, spillways, tunnels, cut slopes, sluices, water intake and measuring works, ship locks and lifts, as well as fish ways. Particular attention is paid to considerations concerning the environment, hydrology, geology and materials etc. in the planning and design of hydraulic projects. It also considers the type selection, profile configuration, stress/stability calibration and engineering countermeasures, flood releasing arrangements and scouring protection, operation and maintenance etc. for a variety of specific hydraulic structures. The book is primarily intended for engineers, undergraduate and graduate students in the field of civil and hydraulic engineering who are faced with the challenges of extending our understanding of hydraulic structures ranging from traditional to groundbreaking, as well as designing, constructing and managing safe, durable hydraulic structures that are economical ...

  5. HYDRAULIC SERVO

    Science.gov (United States)

    Wiegand, D.E.

    1962-05-01

    A hydraulic servo is designed in which a small pressure difference produced at two orifices by an electrically operated flapper arm in a constantly flowing hydraulic loop is hydraulically amplified by two constant flow pumps, two additional orifices, and three unconnected ball pistons. Two of the pistons are of one size and operate against the additional orifices, and the third piston is of a different size and operates between and against the first two pistons. (AEC)

  6. Analysis list: Clamp [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Clamp Cell line + dm3 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/target/Clamp.1....tsv http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/target/Clamp.5.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/target/Clam...p.10.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/colo/Clamp.Cell_line.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/colo/Cell_line.gml ...

  7. Is early cord clamping, delayed cord clamping or cord milking best?

    Science.gov (United States)

    Vatansever, Binay; Demirel, Gamze; Ciler Eren, Elif; Erel, Ozcan; Neselioglu, Salim; Karavar, Hande Nur; Gundogdu, Semra; Ulfer, Gozde; Bahadir, Selcen; Tastekin, Ayhan

    2017-03-20

    To compare the antioxidant status of three cord clamping procedures (early clamping, delayed clamping and milking) by analyzing the thiol-disulfide balance. This randomized controlled study enrolled 189 term infants who were divided into three groups according to the cord clamping procedure: early clamping, delayed clamping and milking. Blood samples were collected from the umbilical arteries immediately after clamping, and the thiol/disulfide homeostasis was analyzed. The native and total thiol levels were significantly (p cord clamping group compared with the other two groups. The disulfide/total thiol ratio was significantly (p = .026) lower in the delayed cord clamping and milking groups compared with the early clamping groups. Early cord clamping causes the production of more disulfide bonds and lower thiol levels, indicating that oxidation reactions are increased in the early cord clamping procedure compared with the delayed cord clamping and milking procedures. The oxidant capacity is greater with early cord clamping than with delayed clamping or cord milking. Delayed cord clamping or milking are beneficial in neonatal care, and we suggest that they be performed routinely in all deliveries.

  8. Delayed umbilical cord clamping in premature neonates.

    Science.gov (United States)

    Kaempf, Joseph W; Tomlinson, Mark W; Kaempf, Andrew J; Wu, YingXing; Wang, Lian; Tipping, Nicole; Grunkemeier, Gary

    2012-08-01

    Delayed umbilical cord clamping is reported to increase neonatal blood volume. We estimated the clinical outcomes in premature neonates who had delayed umbilical cord clamping compared with a similar group who had early umbilical cord clamping. This was a before-after investigation comparing early umbilical cord clamping with delayed umbilical cord clamping (45 seconds) in two groups of singleton neonates, very low birth weight (VLBW) (401-1,500 g) and low birth weight (LBW) (greater than 1,500 g but less than 35 weeks gestation). Neonates were excluded from delayed umbilical cord clamping if they needed immediate major resuscitation. Primary outcomes were provision of delivery room resuscitation, hematocrit, red cell transfusions, and the principle Vermont Oxford Network outcomes. In VLBW neonates (77 delayed umbilical cord clamping, birth weight [mean±standard deviation] 1,099±266 g; 77 early umbilical cord clamping 1,058±289 g), delayed umbilical cord clamping was associated with less delivery room resuscitation, higher Apgar scores at 1 minute, and higher hematocrit. Delayed umbilical cord clamping was not associated with significant differences in the overall transfusion rate, peak bilirubin, any of the principle Vermont Oxford Network outcomes, or mortality. In LBW neonates (172 delayed umbilical cord clamping, birth weight [mean±standard deviation] 2,159±384 g; 172 early umbilical cord clamping 2,203±447 g), delayed umbilical cord clamping was associated with higher hematocrit and was not associated with a change in delivery room resuscitation or Apgar scores or with changes in the transfusion rate or peak bilirubin. Regression analysis showed increasing gestational age and birth weight and delayed umbilical cord clamping were the best predictors of higher hematocrit and less delivery room resuscitation. Delayed umbilical cord clamping can safely be performed in singleton premature neonates and is associated with a higher hematocrit, less delivery room

  9. Loading dynamics of a sliding DNA clamp.

    KAUST Repository

    Cho, Won-Ki

    2014-05-22

    Sliding DNA clamps are loaded at a ss/dsDNA junction by a clamp loader that depends on ATP binding for clamp opening. Sequential ATP hydrolysis results in closure of the clamp so that it completely encircles and diffuses on dsDNA. We followed events during loading of an E. coli β clamp in real time by using single-molecule FRET (smFRET). Three successive FRET states were retained for 0.3 s, 0.7 s, and 9 min: Hydrolysis of the first ATP molecule by the γ clamp loader resulted in closure of the clamp in 0.3 s, and after 0.7 s in the closed conformation, the clamp was released to diffuse on the dsDNA for at least 9 min. An additional single-molecule polarization study revealed that the interfacial domain of the clamp rotated in plane by approximately 8° during clamp closure. The single-molecule polarization and FRET studies thus revealed the real-time dynamics of the ATP-hydrolysis-dependent 3D conformational change of the β clamp during loading at a ss/dsDNA junction.

  10. The RFC clamp loader: structure and function.

    Science.gov (United States)

    Yao, Nina Y; O'Donnell, Mike

    2012-01-01

    The eukaryotic RFC clamp loader couples the energy of ATP hydrolysis to open and close the circular PCNA sliding clamp onto primed sites for use by DNA polymerases and repair factors. Structural studies reveal clamp loaders to be heteropentamers. Each subunit contains a region of homology to AAA+ proteins that defines two domains. The AAA+ domains form a right-handed spiral upon binding ATP. This spiral arrangement generates a DNA binding site within the center of RFC. DNA enters the central chamber through a gap between the AAA+ domains of two subunits. Specificity for a primed template junction is achieved by a third domain that blocks DNA, forcing it to bend sharply. Thus only DNA with a flexible joint can bind the central chamber. DNA entry also requires a slot in the PCNA clamp, which is opened upon binding the AAA+ domains of the clamp loader. ATP hydrolysis enables clamp closing and ejection of RFC, completing the clamp loading reaction.

  11. Basic hydraulics

    CERN Document Server

    Smith, P D

    1982-01-01

    BASIC Hydraulics aims to help students both to become proficient in the BASIC programming language by actually using the language in an important field of engineering and to use computing as a means of mastering the subject of hydraulics. The book begins with a summary of the technique of computing in BASIC together with comments and listing of the main commands and statements. Subsequent chapters introduce the fundamental concepts and appropriate governing equations. Topics covered include principles of fluid mechanics; flow in pipes, pipe networks and open channels; hydraulic machinery;

  12. Hydraulic Structures

    Data.gov (United States)

    Department of Homeland Security — This table is required whenever hydraulic structures are shown in the flood profile. It is also required if levees are shown on the FIRM, channels containing the...

  13. How Does Patch Clamp Work?--An easy approach to understanding patch clamp mechanism

    Institute of Scientific and Technical Information of China (English)

    关兵才; 李之望

    2003-01-01

    In order to help patch clamp users,most of whom are not good enough at electrics and electronics,to understandthe complicated principles of patch clamp technique,we present a readily accessible explanation of patch clamp mechanism,in-cluding basic analysis of membrane currents under voltage clamp,achievement of voltage clamp and current recording,capaci-tance compensation,series resistance compensation,voltage offset correction,leak subtraction and current clamp,based on ourworking and teaching experience and with the aid of some useful formulae.

  14. Electrostatic clamp manufactured by novel method

    NARCIS (Netherlands)

    Sligte, E. te; Storm, A.; Koster, N.B.

    2011-01-01

    Electrostatic clamps (ESCs), used in reticle and wafer handling, are presently manufactured using glass bonding and polishing technologies. We present a patented alternative concept to this process, relying on coating and etching processes rather than bonding. We manufactured a first prototype clamp

  15. 21 CFR 870.4450 - Vascular clamp.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vascular clamp. 870.4450 Section 870.4450 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Surgical Devices § 870.4450 Vascular clamp. (a) Identification. A vascular...

  16. Time to implement delayed cord clamping.

    Science.gov (United States)

    McAdams, Ryan M

    2014-03-01

    Immediate umbilical cord clamping after delivery is routine in the United States despite little evidence to support this practice. Numerous trials in both term and preterm neonates have demonstrated the safety and benefit of delayed cord clamping. In premature neonates, delayed cord clamping has been shown to stabilize transitional circulation, lessening needs for inotropic medications and reducing blood transfusions, necrotizing enterocolitis, and intraventricular hemorrhage. In term neonates, delayed cord clamping has been associated with decreased iron-deficient anemia and increased iron stores with potential valuable effects that extend beyond the newborn period, including improvements in long-term neurodevelopment. The failure to more broadly implement delayed cord clamping in neonates ignores published benefits of increased placental blood transfusion at birth and may represent an unnecessary harm for vulnerable neonates.

  17. Combat ready clamp medic technique.

    Science.gov (United States)

    Tovmassian, Robert V; Kragh, John F; Dubick, Michael A; Baer, David G; Blackbourne, Lorne H

    2012-01-01

    Junctional hemorrhage control device use on the battlefield might be lifesaving, but little experience is reported. The purpose of the present case report is to detail prehospital use of the Combat Ready Clamp (called the CRoC by its users, Combat Medical Systems, Fayetteville, NC; Instructions for Use, 2010) in casualty care in order to increase awareness of junctional hemorrhage control. The CRoC was used to control difficult inguinal bleeding on the battlefield for an Afghani man with a hindquarter traumatic amputation. The device promptly controlled exsanguination from a critical injury when placed during rotary-wing casualty evacuation. The flight medic applied the device in 90 seconds. The device performed well without complications to control bleeding. The CRoC, a new junctional hemorrhage control device, was used as indicated on the battlefield with mechanical and physiologic success and without device problems. By controlling difficult inguinal bleeding resulting from battlefield trauma, the device facilitated casualty stabilization and delivery to a surgical facility. The device facilitated the ability of a new flight medic to focus his expertise on a critically injured battlefield casualty with demonstrable success. 2012.

  18. Dynamic clamp with StdpC software.

    Science.gov (United States)

    Kemenes, Ildikó; Marra, Vincenzo; Crossley, Michael; Samu, Dávid; Staras, Kevin; Kemenes, György; Nowotny, Thomas

    2011-03-01

    Dynamic clamp is a powerful method that allows the introduction of artificial electrical components into target cells to simulate ionic conductances and synaptic inputs. This method is based on a fast cycle of measuring the membrane potential of a cell, calculating the current of a desired simulated component using an appropriate model and injecting this current into the cell. Here we present a dynamic clamp protocol using free, fully integrated, open-source software (StdpC, for spike timing-dependent plasticity clamp). Use of this protocol does not require specialist hardware, costly commercial software, experience in real-time operating systems or a strong programming background. The software enables the configuration and operation of a wide range of complex and fully automated dynamic clamp experiments through an intuitive and powerful interface with a minimal initial lead time of a few hours. After initial configuration, experimental results can be generated within minutes of establishing cell recording.

  19. Molecular Mechanisms of DNA Polymerase Clamp Loaders

    Science.gov (United States)

    Kelch, Brian; Makino, Debora; Simonetta, Kyle; O'Donnell, Mike; Kuriyan, John

    Clamp loaders are ATP-driven multiprotein machines that couple ATP hydrolysis to the opening and closing of a circular protein ring around DNA. This ring-shaped clamp slides along DNA, and interacts with numerous proteins involved in DNA replication, DNA repair and cell cycle control. Recently determined structures of clamp loader complexes from prokaryotic and eukaryotic DNA polymerases have revealed exciting new details of how these complex AAA+ machines perform this essential clamp loading function. This review serves as background to John Kuriyan's lecture at the 2010 Erice School, and is not meant as a comprehensive review of the contributions of the many scientists who have advanced this field. These lecture notes are derived from recent reviews and research papers from our groups.

  20. Clamp force and alignment checking device

    Energy Technology Data Exchange (ETDEWEB)

    Spicer, John Patrick; Cai, Wayne W.; Chakraborty, Debejyo; Mink, Keith

    2017-04-11

    A check fixture measures a total clamp force applied by a welder device. The welder device includes a welding horn having a plurality of weld pads and welding anvil having a plurality of weld pads. The check fixture includes a base member operatively supporting a plurality of force sensors. The base member and the force sensors are received between the weld pads of the welding horn and the anvil pads of the welding anvil. Each force sensor is configured to measure an individual clamp force applied thereto by corresponding weld and anvil pads when the base member is received between the welding horn and the welding anvil and the welder device is in the clamped position. The individual clamp forces are used to determine whether the weld and/or anvil pads are worn or misaligned.

  1. Ergonomic redesign and evaluation of a clamping tool handle.

    Science.gov (United States)

    Jung, Myung-Chul; Hallbeck, M Susan

    2005-09-01

    The handle of a commercial bar clamp was redesigned using ergonomic principles and then compared with an original clamp. Ten male and ten female students participated in simulated clamping tasks under various conditions, including different clamping heights, clamping methods, and handle-gripping methods, with respect to the dependent variables of clamping and handle-squeezing forces. The results showed that the redesigned clamp produced larger clamping force with lower handle-squeezing forces than the original clamp. As expected, males exerted more force than females in both clamping and squeezing forces. A pistol grip method was superior to an upside-down handle-gripping method. Two-handed operation was recommended for this type of clamp by simultaneously pulling the trigger and sliding the bar in order to initially tighten around objects. This study shows that the application of ergonomic guidelines increases the efficiency and usability of manual handtools.

  2. 座面可调电动轮椅的机构运动仿真%Kinematics Simulation for a Power Wheelchair with Self-Actuated Seating Fnctions

    Institute of Scientific and Technical Information of China (English)

    王芳; 张建国

    2013-01-01

    The mechanism of a wheelchair with self-actuated seating.functions was presented,including tilt-in-space,and backrest recline.Each link length was determined according to ergonomics and position analysis.In sofiwar Matlab,a kinematics model of wheelchair was developed and the motion of mechanical linkages was simulated to realize the velocity and acceleration analysis.In the way,the fidelity of the construction was demonstrated by comparing the behavior of the moving drawings with the real mechanism's requirement.The described wheelchair should bring greater freedom of movement to people and dock with other rehabilitation equipment.The mechanism design method should enable better improving design plans according to functional requirement,which could shorten the time of design.%通过运动仿真,对座面可调的多功能轮椅进行机构设计.基于人机工程学及位姿分析,设计各构件尺寸.在MATLAB中建立轮椅运动学模型,通过仿真分析得到了各刚体关键铰接点的位移、速度、加速度等参数.将得到的运动学参数与轮椅的功能要求进行比较,对轮椅整车机构进行修正.所设计的轮椅能辅助残障者实现坐立、站立、平躺等多种姿态间的转变,也便于轮椅与其它康复设备的安全对接.多刚体运动学仿真方法能更直观进行机构功能分析,从而缩短设计周期.

  3. Kinematic and mechanical profile of the self-actuation of thermosalient crystal twins of 1,2,4,5-tetrabromobenzene: a molecular crystalline analogue of a bimetallic strip.

    Science.gov (United States)

    Sahoo, Subash Chandra; Sinha, Shashi Bhushan; Kiran, M S R N; Ramamurty, Upadrasta; Dericioglu, Arcan F; Reddy, C Malla; Naumov, Panče

    2013-09-18

    A paradigm shift from hard to flexible, organic-based optoelectronics requires fast and reversible mechanical response from actuating materials that are used for conversion of heat or light into mechanical motion. As the limits in the response times of polymer-based actuating materials are reached, which are inherent to the less-than-optimal coupling between the light/heat and mechanical energy in them, a conceptually new approach to mechanical actuation is required to leapfrog the performance of organic actuators. Herein, we explore single crystals of 1,2,4,5-tetrabromobenzene (TBB) as actuating elements and establish relations between their kinematic profile and mechanical properties. Centimeter-size acicular crystals of TBB are the only naturally twinned crystals out of about a dozen known materials that exhibit the thermosalient effect-an extremely rare and visually impressive crystal locomotion. When taken over a phase transition, crystals of this material store mechanical strain and are rapidly self-actuated to sudden jumps to release the internal strain, leaping up to several centimeters. To establish the structural basis for this colossal crystal motility, we investigated the mechanical profile of the crystals from macroscale, in response to externally induced deformation under microscope, to nanoscale, by using nanoindentation. Kinematic analysis based on high-speed recordings of over 200 twinned TBB crystals exposed to directional or nondirectional heating unraveled that the crystal locomotion is a kinematically complex phenomenon that includes at least six kinematic effects. The nanoscale tests confirm the highly elastic nature, with an elastic deformation recovery (60%) that is far superior to those of molecular crystals reported earlier. This property appears to be critical for accumulation of stress required for crystal jumping. Twinned crystals of TBB exposed to moderate directional heating behave as all-organic analogue of a bimetallic strip, where

  4. Piezoresistive cantilever force-clamp system

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung-Jin; Petzold, Bryan C.; Pruitt, Beth L. [Department of Mechanical Engineering, Stanford University, Stanford, California 94305 (United States); Goodman, Miriam B. [Department of Molecular and Cellular Physiology, Stanford University, Stanford, California 94305 (United States)

    2011-04-15

    We present a microelectromechanical device-based tool, namely, a force-clamp system that sets or ''clamps'' the scaled force and can apply designed loading profiles (e.g., constant, sinusoidal) of a desired magnitude. The system implements a piezoresistive cantilever as a force sensor and the built-in capacitive sensor of a piezoelectric actuator as a displacement sensor, such that sample indentation depth can be directly calculated from the force and displacement signals. A programmable real-time controller operating at 100 kHz feedback calculates the driving voltage of the actuator. The system has two distinct modes: a force-clamp mode that controls the force applied to a sample and a displacement-clamp mode that controls the moving distance of the actuator. We demonstrate that the system has a large dynamic range (sub-nN up to tens of {mu}N force and nm up to tens of {mu}m displacement) in both air and water, and excellent dynamic response (fast response time, <2 ms and large bandwidth, 1 Hz up to 1 kHz). In addition, the system has been specifically designed to be integrated with other instruments such as a microscope with patch-clamp electronics. We demonstrate the capabilities of the system by using it to calibrate the stiffness and sensitivity of an electrostatic actuator and to measure the mechanics of a living, freely moving Caenorhabditis elegans nematode.

  5. Arterial clamping leads to stenosis at clamp sites after femoropopliteal bypass surgery

    NARCIS (Netherlands)

    Vriens, Bianca H. R.; Pol, Robert A.; Hulsebos, Robin G.; van Det, Rob J.; van der Palen, Job; Zeebregts, Clark J.; Geelkerken, Robert H.

    2015-01-01

    BACKGROUND: To date, the incidence and clinical relevance of arterial stenosis at clamp sites after femoropopliteal bypass surgery is unknown. METHODS: Ninety-four patients underwent a femoropopliteal bypass in which the arterial inflow and outflow clamp sites were controlled by the Fogarty-Soft-Inl

  6. Arterial clamping leads to stenosis at clamp sites after femoropopliteal bypass surgery

    NARCIS (Netherlands)

    Vriens, Bianca H.R.; Pol, Robert A.; Hulsebos, Robin G.; Det, van Rob J.; Palen, van der Job; Zeebregts, Clark J.; Geelkerken, Robert H.

    2015-01-01

    Background To date, the incidence and clinical relevance of arterial stenosis at clamp sites after femoropopliteal bypass surgery is unknown. Methods Ninety-four patients underwent a femoropopliteal bypass in which the arterial inflow and outflow clamp sites were controlled by the Fogarty-Soft-Inla

  7. Vascular clamping in liver surgery: physiology, indications and techniques

    Directory of Open Access Journals (Sweden)

    Cherqui Daniel

    2010-03-01

    Full Text Available Abstract This article reviews the historical evolution of hepatic vascular clamping and their indications. The anatomic basis for partial and complete vascular clamping will be discussed, as will the rationales of continuous and intermittent vascular clamping. Specific techniques discussed and described include inflow clamping (Pringle maneuver, extra-hepatic selective clamping and intraglissonian clamping and outflow clamping (total vascular exclusion, hepatic vascular exclusion with preservation of caval flow. The fundamental role of a low Central Venous Pressure during open and laparoscopic hepatectomy is described, as is the difference in their intra-operative measurements. The biological basis for ischemic preconditioning will be elucidated. Although the potential dangers of vascular clamping and the development of modern coagulation devices question the need for systemic clamping; the pre-operative factors and unforseen intra-operative events that mandate the use of hepatic vascular clamping will be highlighted.

  8. Compact, Stiff, Remotely-Actuable Quick-Release Clamp

    Science.gov (United States)

    Tsai, Ted W. (Inventor)

    2000-01-01

    The present invention provides a clamp that is compact and lightweight, yet provides high holding strength and stiffness or rigidity. The clamp uses a unique double slant interface design which provides mechanical advantages to resist forces applied to the clamp member as the load increases. The clamp allows for rapid and remote-activated release of the clamp jaws by applying only a small operating force to an over-center lock/release mechanism, such as by pulling a manual tether.

  9. IMPORTANT: Fluke is recalling Digital Clamp Meters

    CERN Multimedia

    2013-01-01

    Fluke is voluntarily recalling four models of Digital Clamp Meters: Fluke 373, 374, 375 and 376. If you own one of these clamp meters, please stop using it and send it back to Fluke for repair even if you have not experienced problems.   Description of the problem: "The printed circuit assembly may not be properly fastened to the test lead input jack. This may result in inaccurate voltage readings, including a low or no-voltage reading on a circuit energised with a hazardous voltage, presenting a shock, electrocution or thermal burn hazard." To determine if your clamp meter is affected by this recall notice, and for more information, click here.

  10. Design and application of multifunctional stomach clamp

    Institute of Scientific and Technical Information of China (English)

    Yun Fu Lu; Pi Wu Li; Xir Xin Zhang

    2000-01-01

    AIM Pylorus and pyloric vagus preserving gastrectomy (PPVPG) is an efficient operation mode for treatinggastric and duodenal ulcers. For its better application and popularization, we have designed andmanufactured a special multifunctional stomach clamp.METHODS The clamp has been designed carefully in view of the different sizes of the patients' stomachsand the different starting points of Latarjer nerves so as to facilitate the execution of the present operationmode, which requires the preservation of the vagus innervated pyloric region so as to make the remnantstomach maintain its normal physiological function and the vagus branches clinging antral seromuscular flapkept in proper size so that avoiding too much remaining antral mucosa is removed to cause greater difficultyin operation. With this in view, we observed and measured the distance between the Latarjer nerves distribution and the pyloric rings of 42 patients' stomachs in the course of operations. We bent an aluminumstring 3 mm thick for each stomach according to the size of antral seromuecular flap and chose an optimalcurvature from the 42 sizes for manufacturing the clamp. The clamp is made of 3 Cr13 stainless steel,consisting of three parts, the curved head, the fastening ring and the handle. The curved head is shapedalmost exactly like the remained antral seromuscular flap. The ring at its tip when in place fastens the twosides of the clamp so that the tissue of the stomach between will be clutched by an even force. On one sideare three cuts for moving the ring upwards, each cut representing 1 mm for fastening and adjustments can bemade in view of the thickness or thinness of the tissue. The handles bend backward for fighting shy of thecuts so as to facilitate the operation.RESULTS With the stomach disassociated in the light of PPVPG procedures, the clamp may easily beapplied from the upper part of the Latarjer nerves. The following merits can be noted. ① The curving line ofthe flap can be precisely

  11. Prolonged penile strangulation with metal clamps

    Institute of Scientific and Technical Information of China (English)

    Chirag Patel; Richard Kim; Michael Delterzo; Run Wang

    2006-01-01

    Various different objects have been reported to strangulate the penis. We reported on a patient who used metal radiator clamps for an extended period of time. Workup included history, physical examination and urinalysis. The patient was taken to the operating room for further evaluation with cystourethroscopy and orthopedic wire cutters were used to break the metal bands.

  12. Cerebral haemodynamics during carotid cross-clamping.

    Science.gov (United States)

    Pistolese, G R; Ippoliti, A; Appolloni, A; Ronchey, S; Faraglia, V

    1993-03-01

    Carotid artery cross-clamping ischaemia during carotid endarterectomy (CEA) causes 5-30% of perioperative neurological deficits. This study was performed to identify possible clinical situations at higher risk for carotid cross-clamping ischaemia. 606 consecutive patients underwent CEA and were retrospectively studied; they were grouped according to risk factors, presence of associated vascular diseases, clinical pattern, angiographic and CT scan findings. Stump pressure measurement was provided in all patients, perioperative monitoring during CEA was performed by electroencephalogram (EEG) in 469 (77%) and somatosensorial evoked potentials (SEP) in 137 (23%). Local anaesthesia was used in 88 (14.5%) patients. Ischaemic changes during carotid cross-clamping were registered in 118 patients (19.5%). The incidence of cross-clamping ischaemia was then related to different factors; it affected 5.6% of asymptomatics, 25.4% of patients with fixed stroke and 38.5% of those with stenosis and contralateral occlusion. Angiographic and clinical correlation showed that patients with more severe lesions are mostly affected by clamping ischaemia (up to 55% in those with stroke and stenosis with contralateral occlusion). Age, hypertension and diabetes do not significantly affect incidence of ischaemic changes. Positive CT scan increased this risk; statistical relevance was found in regard to patients with unilateral or bilateral stenosis and in those with transient ischaemic attacks. A higher risk can be expected for subjects with more severe clinical and instrumental findings, even if no patients can be considered completely at risk or risk free. Perioperative monitoring is always mandatory and is of great importance in detecting ischaemic changes and preventing cerebral damage using a temporary intraluminal shunt.

  13. Dynamics and Stability of Pinned-Clamped and Clamped-Pinned Cylindrical Shells Conveying Fluid

    Science.gov (United States)

    Misra, A. K.; Wong, S. S. T.; Païdoussis, M. P.

    2001-11-01

    The paper examines the dynamics and stability of fluid-conveying cylindrical shells having pinned-clamped or clamped-pinned boundary conditions, where ``pinned'' is an abbreviation for ``simply supported''. Flügge's equations are used to describe the shell motion, while the fluid-dynamic perturbation pressure is obtained utilizing the linearized potential flow theory. The solution is obtained using two methods - the travelling wave method and the Fourier-transform approach. The results obtained by both methods suggest that the negative damping of the clamped-pinned systems and positive damping of the pinned-clamped systems, observed by previous investigators for any arbitrarily small flow velocity, are simply numerical artefacts; this is reinforced by energy considerations, in which the work done by the fluid on the shell is shown to be zero. Hence, it is concluded that both systems are conservative.

  14. Research and development of a self-centering clamping device for deep-water multifunctional pipeline repair machinery

    Directory of Open Access Journals (Sweden)

    Liquan Wang

    2016-01-01

    Full Text Available When multifunctional pipeline repair machinery (MPRM is used in the deep sea area, it is difficult to grip the pipeline and ensure concentricity between the cutter heads and the pipeline during its operation. In view of this, a new system of two-arm holding self-centering pipeline clamping device was proposed. The system is composed of two groups of parallelogram double-rocker mechanism and cranking block mechanism which are symmetrically distributed on the frame. The geometric parameter solutions of the clamping device were analyzed with motion and transmission as the constraints. A mechanical model was established to associate the friction torque of clamping points with the driving force. Clamping device and machinery were designed and manufactured for the Ø304.8–457.2 mm pipelines used in this test. ADAMS simulation experiments were conducted underwater, and the cutting and beveling tests were carried out onshore. The following results are achieved. First, the smaller the pipe diameter, the smaller the transmission angle of the oscillating slider mechanism; the longer the hydraulic cylinder stroke, the greater the transmission angle of the double rocker mechanism. Second, the driving force of the clamping device increases with the increase of the pipe diameter. When the diameter reaches 457.2 mm, the hydraulic cylinder driving force of the clamping device should be greater than 10219 N. Third, the feed rate of the cutters increases suddenly due to the slight shaking of the machinery which occurs at the beginning of the pipe cutting, so it is necessary to adopt a small feed rate. And fourth, onshore experiment results agree well with the theoretical design and simulation results, proving the rationality of the system. The research results in this paper provide technical basis for the research and development of similar engineering prototypes.

  15. Imperfect space clamp permits electrotonic interactions between inhibitory and excitatory synaptic conductances, distorting voltage clamp recordings.

    Directory of Open Access Journals (Sweden)

    Alon Poleg-Polsky

    Full Text Available The voltage clamp technique is frequently used to examine the strength and composition of synaptic input to neurons. Even accounting for imperfect voltage control of the entire cell membrane ("space clamp", it is often assumed that currents measured at the soma are a proportional indicator of the postsynaptic conductance. Here, using NEURON simulation software to model somatic recordings from morphologically realistic neurons, we show that excitatory conductances recorded in voltage clamp mode are distorted significantly by neighboring inhibitory conductances, even when the postsynaptic membrane potential starts at the reversal potential of the inhibitory conductance. Analogous effects are observed when inhibitory postsynaptic currents are recorded at the reversal potential of the excitatory conductance. Escape potentials in poorly clamped dendrites reduce the amplitude of excitatory or inhibitory postsynaptic currents recorded at the reversal potential of the other conductance. In addition, unclamped postsynaptic inhibitory conductances linearize the recorded current-voltage relationship of excitatory inputs comprising AMPAR and NMDAR-mediated components, leading to significant underestimation of the relative contribution by NMDARs, which are particularly sensitive to small perturbations in membrane potential. Voltage clamp accuracy varies substantially between neurons and dendritic arbors of different morphology; as expected, more reliable recordings are obtained from dendrites near the soma, but up to 80% of the synaptic signal on thin, distant dendrites may be lost when postsynaptic interactions are present. These limitations of the voltage clamp technique may explain how postsynaptic effects on synaptic transmission could, in some cases, be attributed incorrectly to presynaptic mechanisms.

  16. Towards a Dynamic Clamp for Neurochemical Modalities

    Directory of Open Access Journals (Sweden)

    Catalina Maria Rivera

    2015-05-01

    Full Text Available The classic dynamic clamp technique uses a real-time electrical interface between living cells and neural simulations in order to investigate hypotheses about neural function and structure. One of the acknowledged drawbacks of that technique is the limited control of the cells’ chemical microenvironment. In this manuscript, we use a novel combination of nanosensor and microfluidic technology and microfluidic and neural simulations to add sensing and control of chemical concentrations to the dynamic clamp technique. Specifically, we use a microfluidic lab-on-a-chip to generate distinct chemical concentration gradients (ions or neuromodulators, to register the concentrations with embedded nanosensors and use the processed signals as an input to simulations of a neural cell. The ultimate goal of this project is to close the loop and provide sensor signals to the microfluidic lab-on-a-chip to mimic the interaction of the simulated cell with other cells in its chemical environment.

  17. Mechanical and metallurgical properties of carotid artery clamps.

    Science.gov (United States)

    Dujovny, M; Kossovsky, N; Kossowsky, R; Segal, R; Diaz, F G; Kaufman, H; Perlin, A; Cook, E E

    1985-11-01

    The mechanical and metallurgical properties of carotid artery clamps were evaluated. The pressure plate retreat propensity, metallurgical composition, surface morphology, magnetic properties, and corrosion resistance of the Crutchfield, Selverstone, Salibi, and Kindt clamps were tested. None of the clamps showed evidence of pressure plate retreat. The clamps differed significantly in their composition, surface cleanliness, magnetic properties, and corrosion resistance. The Crutchfield clamp was the only one manufactured from an ASTM-ANSI-approved implantable stainless steel (AISI 316) and the only clamp in which the surfaces were clean and free of debris. The Selverstone clamp was made principally from AISI 304 stainless steel, as was one Salibi clamp. The pressure plate on another Salibi clamp was made from a 1% chromium and 1% manganese steel. Machining and surface debris consisting principally of aluminum, silicon, and sulfur was abundant on the Selverstone and Salibi clamps. The Kindt clamp was manufactured from AISI 301 stainless steel with a silicate-aluminized outer coating. The Crutchfield and Selverstone clamps were essentially nonferromagnetic, whereas the Salibi and Kindt clamps were sensitive to magnetic flux. In the pitting potential corrosion test, the Crutchfield clamp demonstrated good corrosion resistance with a pitting potential of 310 mV and no surface corrosion or pitting by scanning electron microscopy examination. The Selverstone clamp had lower pitting potentials and showed various degrees of corrosion and surface pitting by scanning electron microscopy. The Salibi pressure plate had a very low pitting potential of -525 mV and showed severe corrosion. By metallurgical criteria, only the Crutchfield clamp is suitable for long term implantation.

  18. Γ-source Neutral Point Clamped Inverter

    DEFF Research Database (Denmark)

    Mo, Wei; Loh, Poh Chiang; Blaabjerg, Frede

    Transformer based Z-source inverters are recently proposed to achieve promising buck-boost capability. They have improved higher buck-boost capability, smaller size and less components count over Z-source inverters. On the other hand, neutral point clamped inverters have less switching stress...... and better output performance comparing with traditional two-level inverters. Integrating these two types of configurations can help neutral point inverters achieve enhanced votlage buck-boost capability....

  19. AN ACTIVE VALVE WITH A CLAMPED MEMBRANE

    DEFF Research Database (Denmark)

    2009-01-01

    An active valve for use e.g. in fluidic microsystems is provided, wherein the active valve comprises a membrane having at least one flow gate, arranged between a first and a second substantially rigid element. Adjusting means provides an adjustment of the clamping force on membrane arranged between...... the first and second substantially rigid element. Hereby the flow rate through the active valve can be continuously and precisely controlled....

  20. Vibration of an eccentrically clamped annular plate

    Science.gov (United States)

    Tseng, J.-G.; Wickert, J. A.

    1994-04-01

    Small amplitude vibration of an eccentric annular plate, which is free along its outer edge and clamped along the interior, is investigated through experimental and analytical methods. A disk with this geometry, or a stacked array in which the clamping and symmetry axes of each disk are nominally coincident, is common in data storage and brake systems applications. In the present case, the geometric imperfections on the boundary can have important implications for the disk's dynamic response. Changes that occur in the natural frequency spectrum, the mode shapes, and the free response under eccentric mounting are studied through laboratory measurements and an approximate discrete model of the plate. The natural frequencies and modes are found through global discretization of the Kamke quotient for a classical thin plate. For the axisymmetric geometry, the natural frequencies of the sine and cosine vibration modes for a specified number of nodal diameters are repeated. With increasing eccentricity, on the other hand, each pair of repeated frequencies splits at a rate that depends on the number of nodal diameters. Over a range of clamping and eccentricity ratios, the model's predictions are compared to the measured results.

  1. Multilevel-clamped multilevel converters (MLC2)

    DEFF Research Database (Denmark)

    Rodriguez, Pedro; Bellar, Maria Dias; Muñoz-Aguliar, Raúl Santiago;

    2012-01-01

    This letter introduces a new series of multilevel (ML) converters based on the ML clamping concept. By applying this technique, a ML clamping unit (MCU) conveys additional levels for synthesizing the output waveforms of a diode-clampedML dc– ac power converter. The basic building block of the ML ...

  2. Analysis of the Pallet Clamping Conditions in Work Positioning

    Directory of Open Access Journals (Sweden)

    L. A. Kolesnikov

    2016-01-01

    Full Text Available Pallets of automatic transfer lines serve as the technological and work-transfer equipment. However, their design is based on the general principles of designing machine accessories. Calculation of the basic design parameters of work based on their functioning features is fairly relevant.In pallet transfer movement over work positioning there is a mismatch between axes of the basic bushing of a pallet and the clamping locks of positioning. The paper identifies the factors influencing it, and defines the conditions to ensure the trouble-free clamping lock. The circular and rhombic clamping of pallet is simultaneous. Further, a clamping load is calculated from the pallet mass (together with the work-piece and the geometric parameters of the pallet clamping.The paper reveals three movement stages of the clamping lock in a vertical plane when setting the pallet in work positioning:- a clamping lock free play till it encounters with the location bushing;- a clamping lock play length when the lead-in chamfer contacts the bushing chamfer;- a clamping lock play length over the circular surface of bushing.The study of this process has allowed us to calculate the time of pallet clamping and dynamic loads acting on the clamping lock. These calculations made it possible to calculate the required diameter of the clamping lock. The presented calculations allow a reasonable assigning the main design parameters of work positioning for the pallet automatic lines.

  3. Single molecule study of a processivity clamp sliding on DNA

    Energy Technology Data Exchange (ETDEWEB)

    Laurence, T A; Kwon, Y; Johnson, A; Hollars, C; O?Donnell, M; Camarero, J A; Barsky, D

    2007-07-05

    Using solution based single molecule spectroscopy, we study the motion of the polIII {beta}-subunit DNA sliding clamp ('{beta}-clamp') on DNA. Present in all cellular (and some viral) forms of life, DNA sliding clamps attach to polymerases and allow rapid, processive replication of DNA. In the absence of other proteins, the DNA sliding clamps are thought to 'freely slide' along the DNA; however, the abundance of positively charged residues along the inner surface may create favorable electrostatic contact with the highly negatively charged DNA. We have performed single-molecule measurements on a fluorescently labeled {beta}-clamp loaded onto freely diffusing plasmids annealed with fluorescently labeled primers of up to 90 bases. We find that the diffusion constant for 1D diffusion of the {beta}-clamp on DNA satisfies D {le} 10{sup -14} cm{sup 2}/s, much slower than the frictionless limit of D = 10{sup -10} cm{sup 2}/s. We find that the {beta} clamp remains at the 3-foot end in the presence of E. coli single-stranded binding protein (SSB), which would allow for a sliding clamp to wait for binding of the DNA polymerase. Replacement of SSB with Human RP-A eliminates this interaction; free movement of sliding clamp and poor binding of clamp loader to the junction allows sliding clamp to accumulate on DNA. This result implies that the clamp not only acts as a tether, but also a placeholder.

  4. 21 CFR 882.4460 - Neurosurgical head holder (skull clamp).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neurosurgical head holder (skull clamp). 882.4460 Section 882.4460 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... holder (skull clamp). (a) Identification. A neurosurgical head holder (skull clamp) is a device used...

  5. HYDRAULICS, LOUISA COUNTY, USA

    Data.gov (United States)

    Federal Emergency Management Agency, Department of Homeland Security — Hydraulic data include spatial datasets and data tables necessary for documenting the hydraulic analysis for estimating flood stages for a flood insurance study. It...

  6. Hydraulic Hybrid Vehicles

    Science.gov (United States)

    EPA and the United Parcel Service (UPS) have developed a hydraulic hybrid delivery vehicle to explore and demonstrate the environmental benefits of the hydraulic hybrid for urban pick-up and delivery fleets.

  7. Timing of umbilical cord clamping of term infants.

    Science.gov (United States)

    Ceriani Cernadas, José María

    2017-04-01

    For at least over 200 years, multiple controversies have arisen around the timing of umbilical cord clamping. In the past decades, early cord clamping (within the first 15 seconds) had markedly prevailed. Only in the 21st century, randomized controlled trials have demonstrated the benefits of delayed cord clamping (at 2-3 minutes). Delayed cord clamping has been practiced in obstetrics based on the recommendations made by scientific societies and in systematic reviews, which have provided solid evidence to support this practice in term infants. This review describes the most relevant factors supporting the use of delayed cord clamping in term infants. It points out the essential role played by physiological mechanisms which, undoubtedly, allow us to understand the benefits of delayed cord clamping and advise us to wait for what nature has established. Other relevant aspects supporting delayed cord clamping are also described here. Sociedad Argentina de Pediatría.

  8. Optimization of a clamped plate silencer.

    Science.gov (United States)

    Wang, Chunqi; Han, Jun; Huang, Lixi

    2007-02-01

    A previous theoretical study [L. Huang, J. Acoust. Soc. Am. 119, 2628-2638 (2006)] shows that, in a duct, a simply supported plate covering a side-branch rigid cavity can function effectively as a wave reflector over a broad range of low to medium frequencies. In this study, analytical formulation is extended to the boundary condition of clamped plate, which is easier to implement in practice. The theoretical model is tested experimentally using balsawood, which has a very high stiffness to mass ratio. The spectral peaks and shapes of the measured TL are in agreement with those calculated theoretically, attempts are also made to account for the considerable sound absorption in the rig. Further numerical studies based on the validated model show that, for a uniform plate, the optimal stopband is narrower and the lower band limit is worse than that of the simply supported configuration. However, a wave reflector using nonuniform, clamped plates with thinner ends out-performs the simply supported configuration in every aspect. Analyses show that the improvement is attributed to the increased acoustic radiation efficiency over the bulk length of the nonuniform plate, which behaves more like a rigid plate.

  9. Obstetricians' attitudes and beliefs regarding umbilical cord clamping.

    Science.gov (United States)

    Jelin, Angie C; Kuppermann, Miriam; Erickson, Kristine; Clyman, Ronald; Schulkin, Jay

    2014-09-01

    Although delayed umbilical cord clamping has been demonstrated to reduce the incidence of intraventricular hemorrhage and neonatal sepsis, and decrease the need for neonatal transfusions (without affecting cord pH, Apgar scores or the need for phototherapy), the extent to which this practice is being employed is unknown. We conducted a survey of US obstetricians to assess their attitudes and beliefs about cord clamping. Questionnaires were randomly mailed to members of the American College of Obstetricians and Gynecologists (ACOG), and the Collaborative Ambulatory Research Network (CARN). The data were analyzed using Chi-square and Student t tests. The response rates for the CARN and other ACOG members were 47% and 21%, respectively. Most (88%) responders reported their hospital had no umbilical cord clamping policy. The most frequent response for optimal timing of umbilical cord clamping, regardless of gestational age, was "don't know". Potential for neonatal red blood cell transfusion was the only concern cited as a reason for being somewhat or very inclined to delay umbilical cord clamping (51%). Delayed neonatal resuscitation (76%) was listed as a reason to clamp the cord immediately, despite the paucity of literature to support immediate cord clamping in this cohort. Despite substantial evidence supporting the practice of delayed cord clamping, few institutions have policies regarding this practice. Moreover, obstetricians' beliefs about the appropriate timing for umbilical cord clamping are not consistent with the evidence that demonstrates its beneficial impact on neonatal outcomes.

  10. Delayed cord clamping and cord gas analysis at birth.

    Science.gov (United States)

    Xodo, Serena; Xodo, Luigi; Berghella, Vincenzo

    2017-09-16

    Delayed cord clamping for at least 60 seconds in both term and preterm babies is a major recent change in clinical care. Delayed cord clamping has several effects on other possible interventions. One of these is the effect of delayed cord clamping on umbilical artery gas analysis. When indicated, umbilical artery gas analysis can safely be done either with early cord clamping, or, probably most of the times it is necessary, during delayed cord clamping with the cord still unclamped. Paired blood samples (one from the umbilical artery and one from the umbilical vein) can be taken from the pulsating and unclamped cord, immediately after birth, during delayed cord clamping, without any effect on either the accuracy of umbilical artery gas analysis or on the transfusion of blood through delayed cord clamping. Umbilical artery gas analysis should instead not be done after delayed cord clamping, since delayed cord clamping alters several acid-based parameters and lactate values. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  11. Thermal stiffening of clamped elastic ribbons

    Science.gov (United States)

    Wan, Duanduan; Nelson, David R.; Bowick, Mark J.

    2017-07-01

    We use molecular dynamics to study the vibrations of a thermally fluctuating two-dimensional elastic membrane clamped at both ends. We directly extract the eigenmodes from resonant peaks in the frequency domain of the time-dependent height and measure the dependence of the corresponding eigenfrequencies on the microscopic bending rigidity of the membrane, taking care also of the subtle role of thermal contraction in generating a tension when the projected area is fixed. At finite temperatures we show that the effective (macroscopic) bending rigidity tends to a constant as the bare bending rigidity vanishes, consistent with theoretical arguments that the large-scale bending rigidity of the membrane arises from a strong thermal renormalization of the microscopic bending rigidity. Experimental realizations include covalently bonded two-dimensional atomically thin membranes such as graphene and molybdenum disulfide or soft matter systems such as the spectrin skeleton of red blood cells or diblock copolymers.

  12. The PCNA-RFC families of DNA clamps and clamp loaders.

    Science.gov (United States)

    Majka, Jerzy; Burgers, Peter M J

    2004-01-01

    The proliferating cell nuclear antigen PCNA functions at multiple levels in directing DNA metabolic pathways. Unbound to DNA, PCNA promotes localization of replication factors with a consensus PCNA-binding domain to replication factories. When bound to DNA, PCNA organizes various proteins involved in DNA replication, DNA repair, DNA modification, and chromatin modeling. Its modification by ubiquitin directs the cellular response to DNA damage. The ring-like PCNA homotrimer encircles double-stranded DNA and slides spontaneously across it. Loading of PCNA onto DNA at template-primer junctions is performed in an ATP-dependent process by replication factor C (RFC), a heteropentameric AAA+ protein complex consisting of the Rfc1, Rfc2, Rfc3, Rfc4, and Rfc5 subunits. Loading of yeast PCNA (POL30) is mechanistically distinct from analogous processes in E. coli (beta subunit by the gamma complex) and bacteriophage T4 (gp45 by gp44/62). Multiple stepwise ATP-binding events to RFC are required to load PCNA onto primed DNA. This stepwise mechanism should permit editing of this process at individual steps and allow for divergence of the default process into more specialized modes. Indeed, alternative RFC complexes consisting of the small RFC subunits together with an alternative Rfc1-like subunit have been identified. A complex required for the DNA damage checkpoint contains the Rad24 subunit, a complex required for sister chromatid cohesion contains the Ctf18 subunit, and a complex that aids in genome stability contains the Elg1 subunit. Only the RFC-Rad24 complex has a known associated clamp, a heterotrimeric complex consisting of Rad17, Mec3, and Ddc1. The other putative clamp loaders could either act on clamps yet to be identified or act on the two known clamps.

  13. Thermally Actuated Hydraulic Pumps

    Science.gov (United States)

    Jones, Jack; Ross, Ronald; Chao, Yi

    2008-01-01

    Thermally actuated hydraulic pumps have been proposed for diverse applications in which direct electrical or mechanical actuation is undesirable and the relative slowness of thermal actuation can be tolerated. The proposed pumps would not contain any sliding (wearing) parts in their compressors and, hence, could have long operational lifetimes. The basic principle of a pump according to the proposal is to utilize the thermal expansion and contraction of a wax or other phase-change material in contact with a hydraulic fluid in a rigid chamber. Heating the chamber and its contents from below to above the melting temperature of the phase-change material would cause the material to expand significantly, thus causing a substantial increase in hydraulic pressure and/or a substantial displacement of hydraulic fluid out of the chamber. Similarly, cooling the chamber and its contents from above to below the melting temperature of the phase-change material would cause the material to contract significantly, thus causing a substantial decrease in hydraulic pressure and/or a substantial displacement of hydraulic fluid into the chamber. The displacement of the hydraulic fluid could be used to drive a piston. The figure illustrates a simple example of a hydraulic jack driven by a thermally actuated hydraulic pump. The pump chamber would be a cylinder containing encapsulated wax pellets and containing radial fins to facilitate transfer of heat to and from the wax. The plastic encapsulation would serve as an oil/wax barrier and the remaining interior space could be filled with hydraulic oil. A filter would retain the encapsulated wax particles in the pump chamber while allowing the hydraulic oil to flow into and out of the chamber. In one important class of potential applications, thermally actuated hydraulic pumps, exploiting vertical ocean temperature gradients for heating and cooling as needed, would be used to vary hydraulic pressures to control buoyancy in undersea research

  14. Analysis of Contact Characteristic of Overhead Line and Suspension Clamp

    Directory of Open Access Journals (Sweden)

    Zhao Xinze

    2013-01-01

    Full Text Available In this paper, a LGJ150/25 type ACSR transmission line and a CGU-3 type suspension clamp are taken as research objects. A contact model of the conductor and the clamp was established by using finite element method. The effects of sag angle of the conductor, holding force and tension force in section are analyzed. The results showed that the contact area in the middle of the clamp is of belt-like type. The extreme values of tress were observed on the edge of the contact area and near the edge of keeper. In clamp section, suspension angle had the greatest influence on contact stress, and then the clamp force. The tension force in section played a most important role in these affecting factors. In the exit section of clamp, the biggest impact factor was tension force in this section, then the suspension angle, the third was clamp force. The results provide theoretical basis on reducing corona loss, optimization the clamp. Doubtlessly, the conclusion has important theoretical significance and application value.

  15. Advanced patch-clamp techniques and single-channel analysis

    NARCIS (Netherlands)

    Biskup, B; Elzenga, JTM; Homann, U; Thiel, G; Wissing, F; Maathuis, FJM

    1999-01-01

    Much of our knowledge of ion-transport mechanisms in plant cell membranes comes from experiments using voltage-clamp. This technique allows the measurement of ionic currents across the membrane, whilst the voltage is held under experimental control. The patch-clamp technique was developed to study t

  16. Studying mechanosensitive ion channels with an automated patch clamp

    NARCIS (Netherlands)

    Barthmes, Maria; Jose, Mac Donald F; Birkner, Jan Peter; Brüggemann, Andrea; Wahl-Schott, Christian; Kocer, Armagan

    2014-01-01

    Patch clamp electrophysiology is the main technique to study mechanosensitive ion channels (MSCs), however, conventional patch clamping is laborious and success and output depends on the skills of the operator. Even though automated patch systems solve these problems for other ion channels, they cou

  17. Applications of alcohol clamping in early drug development

    NARCIS (Netherlands)

    Zoethout, Remco Wiebe Martijn

    2012-01-01

    This thesis describes the development of a novel alcohol clamp, a new method to obtain stable plasma levels of alcohol and its application in CNS-research. The method might have several advantages that were explored in subsequent studies described in this thesis. The stability of the alcohol clamp w

  18. OPTIMAL TIMING FOR CLAMPING THE UMBILICAL CORD AFTER BIRTH

    Science.gov (United States)

    Raju, Tonse N. K.; Singal, Nalini

    2013-01-01

    Synopsis This paper provides a brief overview of pros and cons of clamping the cord too early (within seconds) after birth. It also highlights evolving data that suggests that delaying cord clamping for 30–60 seconds after birth is beneficial to the baby and the mother, with no measurable negative effects. PMID:23164185

  19. 21 CFR 876.5160 - Urological clamp for males.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Urological clamp for males. 876.5160 Section 876.5160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5160 Urological clamp for...

  20. Vibration of hydraulic machinery

    CERN Document Server

    Wu, Yulin; Liu, Shuhong; Dou, Hua-Shu; Qian, Zhongdong

    2013-01-01

    Vibration of Hydraulic Machinery deals with the vibration problem which has significant influence on the safety and reliable operation of hydraulic machinery. It provides new achievements and the latest developments in these areas, even in the basic areas of this subject. The present book covers the fundamentals of mechanical vibration and rotordynamics as well as their main numerical models and analysis methods for the vibration prediction. The mechanical and hydraulic excitations to the vibration are analyzed, and the pressure fluctuations induced by the unsteady turbulent flow is predicted in order to obtain the unsteady loads. This book also discusses the loads, constraint conditions and the elastic and damping characters of the mechanical system, the structure dynamic analysis, the rotor dynamic analysis and the system instability of hydraulic machines, including the illustration of monitoring system for the instability and the vibration in hydraulic units. All the problems are necessary for vibration pr...

  1. Handbook of hydraulic fluid technology

    CERN Document Server

    Totten, George E

    2011-01-01

    ""The Handbook of Hydraulic Fluid Technology"" serves as the foremost resource for designing hydraulic systems and for selecting hydraulic fluids used in engineering applications. Featuring new illustrations, data tables, as well as practical examples, this second edition is updated with essential information on the latest hydraulic fluids and testing methods. The detailed text facilitates unparalleled understanding of the total hydraulic system, including important hardware, fluid properties, and hydraulic lubricants. Written by worldwide experts, the book also offers a rigorous overview of h

  2. Cell-Detection Technique for Automated Patch Clamping

    Science.gov (United States)

    McDowell, Mark; Gray, Elizabeth

    2008-01-01

    A unique and customizable machinevision and image-data-processing technique has been developed for use in automated identification of cells that are optimal for patch clamping. [Patch clamping (in which patch electrodes are pressed against cell membranes) is an electrophysiological technique widely applied for the study of ion channels, and of membrane proteins that regulate the flow of ions across the membranes. Patch clamping is used in many biological research fields such as neurobiology, pharmacology, and molecular biology.] While there exist several hardware techniques for automated patch clamping of cells, very few of those techniques incorporate machine vision for locating cells that are ideal subjects for patch clamping. In contrast, the present technique is embodied in a machine-vision algorithm that, in practical application, enables the user to identify good and bad cells for patch clamping in an image captured by a charge-coupled-device (CCD) camera attached to a microscope, within a processing time of one second. Hence, the present technique can save time, thereby increasing efficiency and reducing cost. The present technique involves the utilization of cell-feature metrics to accurately make decisions on the degree to which individual cells are "good" or "bad" candidates for patch clamping. These metrics include position coordinates (x,y) in the image plane, major-axis length, minor-axis length, area, elongation, roundness, smoothness, angle of orientation, and degree of inclusion in the field of view. The present technique does not require any special hardware beyond commercially available, off-the-shelf patch-clamping hardware: A standard patchclamping microscope system with an attached CCD camera, a personal computer with an imagedata- processing board, and some experience in utilizing imagedata- processing software are all that are needed. A cell image is first captured by the microscope CCD camera and image-data-processing board, then the image

  3. Trends in Aortic Clamp Use During Coronary Artery Bypass Surgery: The Effect of Aortic Clamping Strategies on Neurologic Outcomes

    Science.gov (United States)

    Daniel, William T.; Kilgo, Patrick; Puskas, John D.; Thourani, Vinod H.; Lattouf, Omar M.; Guyton, Robert A.; Halkos, Michael E.

    2013-01-01

    Objective The purpose of this study was to determine the impact of different clamping strategies during CABG on the incidence of postoperative stroke. Methods In this case-control study, all patients at Emory hospitals from 2002–2009 with postoperative stroke after isolated CABG (N=141) were matched 1:4 to a contemporaneous cohort of patients without postoperative stroke (N=565). Patients were matched according to the Society of Thoracic Surgeons (STS) Predicted Risk of Postoperative Stroke (PROPS), which is based on 26 variables. On- (ONCAB) and off-pump (OPCAB) patients were matched separately. Multiple logistic regression analysis with adjusted odds ratios (OR) was performed to identify operative variables associated with postoperative stroke. Results Among the ONCAB cohort, the single cross-clamp technique was associated with a decreased risk of stroke compared to the double clamp (cross clamp + partial clamp) technique (OR=0.385, p=0.044). Within the OPCAB cohort, there was no significant difference in stroke according to clamp use. Epiaortic ultrasound of the ascending aorta increased from 45.3% in 2002 to 89.4% in 2009. From 2002–2009, clamp use decreased from 97.7% of cases to 72.7%. Conclusions During ONCAB, the use of a single cross-clamp compared to the double clamp technique decreases the risk of postoperative stroke. The use of any aortic clamp has decreased and epiaortic ultrasound use has increased from 2002–2009, indicating a change in operative technique and surgeon awareness of the potential complications associated with manipulation of the aorta. PMID:23477689

  4. Committee Opinion No. 684: Delayed Umbilical Cord Clamping After Birth.

    Science.gov (United States)

    2017-01-01

    Delayed umbilical cord clamping appears to be beneficial for term and preterm infants. In term infants, delayed umbilical cord clamping increases hemoglobin levels at birth and improves iron stores in the first several months of life, which may have a favorable effect on developmental outcomes. There is a small increase in jaundice that requires phototherapy in this group of infants. Consequently, health care providers adopting delayed umbilical cord clamping in term infants should ensure that mechanisms are in place to monitor for and treat neonatal jaundice. In preterm infants, delayed umbilical cord clamping is associated with significant neonatal benefits, including improved transitional circulation, better establishment of red blood cell volume, decreased need for blood transfusion, and lower incidence of necrotizing enterocolitis and intraventricular hemorrhage. Delayed umbilical cord clamping was not associated with an increased risk of postpartum hemorrhage or increased blood loss at delivery, nor was it associated with a difference in postpartum hemoglobin levels or the need for blood transfusion. Given the benefits to most newborns and concordant with other professional organizations, the American College of Obstetricians and Gynecologists now recommends a delay in umbilical cord clamping in vigorous term and preterm infants for at least 30-60 seconds after birth. The ability to provide delayed umbilical cord clamping may vary among institutions and settings; decisions in those circumstances are best made by the team caring for the mother-infant dyad.

  5. Effect of delayed umbilical cord clamping on blood gas analysis.

    Science.gov (United States)

    Valero, Javier; Desantes, Domingo; Perales-Puchalt, Alfredo; Rubio, Juan; Diago Almela, Vicente J; Perales, Alfredo

    2012-05-01

    To ascertain if there are differences in umbilical cord blood gas analysis between immediate and delayed cord clamping. In a prospective observational study on 60 vaginally delivered healthy term newborns, we sampled umbilical cord blood immediately after delivery and at the time umbilical cord pulsation spontaneously ceased. There were significant decreases in pH, oxygen saturation (sO(2)), glycemia, oxygen content (ctO(2)), bicarbonate (HCO(3)(-)) and base excess (BE). Lactate and [Formula: see text] increased. Delayed cord clamping pH correlated with immediate cord clamping pH, [Formula: see text] , ctHb, sO(2) and time (r(2)=0.77, pcord clamping lactate was associated with immediate cord clamping lactate and time (r(2)=0.83, pcord clamping alters acid-base parameters and lactate values compared to immediate cord clamping. Those variations depend mainly on time, prior pH and lactate. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  6. Single electrode dynamic clamp with StdpC.

    Science.gov (United States)

    Samu, David; Marra, Vincenzo; Kemenes, Ildiko; Crossley, Michael; Kemenes, György; Staras, Kevin; Nowotny, Thomas

    2012-10-15

    Dynamic clamp is a powerful approach for electrophysiological investigations allowing researchers to introduce artificial electrical components into target neurons to simulate ionic conductances, chemical or electrotonic inputs or connections to other cells. Due to the rapidly changing and potentially large current injections during dynamic clamp, problematic voltage artifacts appear on the electrode used to inject dynamic clamp currents into a target neuron. Dynamic clamp experiments, therefore, typically use two separate electrodes in the same cell, one for recording membrane potential and one for injecting currents. The requirement for two independent electrodes has been a limiting factor for the use of dynamic clamp in applications where dual recordings of this kind are difficult or impossible to achieve. The recent development of an active electrode compensation (AEC) method has overcome some of these prior limitations, permitting artifact-free dynamic clamp experimentation with a single electrode. Here we describe an AEC method for the free dynamic clamp software StdpC. The AEC component of StdpC is the first such system implemented for the use of non-expert users and comes with a set of semi-automated configuration and calibration procedures that facilitate its use. We briefly introduce the AEC method and its implementation in StdpC and then validate it with an electronic model cell and in two different biological preparations.

  7. Avoiding aortic clamping during CABG reduces postoperative stroke

    Science.gov (United States)

    Moss, Emmanuel; Puskas, John D; Thourani, Vinod H; Kilgo, Patrick; Chen, Edward P; Leshnower, Bradley G; Lattouf, Omar M; Guyton, Robert A.; Glas, Kathryn E; Halkos, Michael E.

    2014-01-01

    Objective The purpose of this study was to determine whether the incidence of postoperative stroke (PS) could be reduced by eliminating aortic clamping during CABG. Methods From 2002–2013, 12,079 patients underwent primary, isolated CABG at a single US academic institution. Aortic manipulation was completely avoided by using in-situ internal mammary arteries for inflow in 1,552 (12.9%) patients (no-touch), a clampless facilitating device (CFD) was used for proximal anastomoses in 1,548 (12.8%) patients, and aortic clamping was used in 8,979 (74.3%) patients. These strategies were assessed in a logistic regression model controlling for relevant variables. Results The overall incidence of PS was 1.4% (n=165), with an unadjusted incidence of 0.6% (n=10) in the no-touch group, 1.2% (n=18) in the CFD group, and 1.5% (n=137) in the clamp group (p<0.01 for no-touch vs clamp). The ratio of observed to expected stroke rate increased as the degree of aortic manipulation increased, from 0.48 in the no-touch group, to 0.61 in the CFD group, and 0.95 in the clamp group. Aortic clamping was independently associated with an increase in PS compared to a no-touch technique (AOR 2.50, p<0.01). When separated by CPB utilization, both the off-pump partial clamp and on-pump cross-clamp techniques increased the risk of PS compared to no-touch (AOR 2.52, p<0.01 and AOR 4.25, p<0.001, respectively). Conclusion A no-aortic touch technique has the lowest risk for postoperative stroke for patients undergoing CABG. Clamping the aorta during CABG increases the risk of PS, regardless of the severity of aortic disease. PMID:25293356

  8. Is "Delayed Umbilical Cord Clamping" Beneficial for Premature Newborns?

    Directory of Open Access Journals (Sweden)

    Amir-Mohammad Armanian

    2017-05-01

    Full Text Available Background: The appropriate moment for clamping the umbilical cord is controversial. Immediate cord clamping (ICC is an item of active management of the third stage of labor (AMTSL. Unclamped umbilical cord may cause inconvenience in preterm neonates because they commonly need some levels of emergent services. Some studies revealed delayed cord clamping (DCC of preterm neonates results in better health conditions like lower rates of respiratory distress syndrome (RDS, less morbidities in labor room and lower risk of postpartum hemorrhage. The aim of the present study was to determine the effect of delayed umbilical cord clamping on premature neonatal outcomes. Materials and Methods: In this single‑center randomized control trial study, sixty premature neonates (gestational age ≤ 34 weeks were randomly assigned to ICC (cord clamped at 5–10 seconds or DCC (30–45 seconds groups and followed up in neonatal intensive care unit (NICU. Primary outcomes were 1st and 5th minute Apgar score, average of level of hematocrit after birth, intra ventricle hemorrhage and need some levels of resuscitation. Results: Differences in demographic characteristics were not statistically significant. After birth, neonates who had delayed clamping had significantly higher mean hematocrit after at 4-hour of birth (49.58+5.15gr/dl vs. 46.58+5.40gr/dlin DCC vs. ICC groups, respectively (P=0.031. Delayed cord clamping reduced the duration of need to nasal continues positive airway pressure (NCPAP (86.7% and 60.0% in ICC and DCC groups, respectively, P= 0.039. Attractively, the results showed lower incidence of clinical sepsis in delayed cord clamping neonates (53.3% vs. 23.3% in ICC and DCC groups, respectively, P=0.033. Conclusion: Prematurity complications might decrease by delay umbilical cord clamping which improve the hematocrit, duration of need to NCPAP and incidence of clinical sepsis. Furthermore, DCC may have no negative impact on neonatal resuscitation.

  9. Integral transform solutions of dynamic response of a clamped-clamped pipe conveying fluid

    Energy Technology Data Exchange (ETDEWEB)

    Gu Jijun; An Chen [Ocean Engineering Program, COPPE, Universidade Federal do Rio de Janeiro, CP 68508, Rio de Janeiro 21941-972 (Brazil); Duan Menglan [Offshore Oil/Gas Research Center, China University of Petroleum, Beijing 102249 (China); Levi, Carlos [Ocean Engineering Program, COPPE, Universidade Federal do Rio de Janeiro, CP 68508, Rio de Janeiro 21941-972 (Brazil); Su Jian, E-mail: sujian@nuclear.ufrj.br [Nuclear Engineering Program, COPPE, Universidade Federal do Rio de Janeiro, CP 68509, Rio de Janeiro 21941-972 (Brazil)

    2013-01-15

    Highlights: Black-Right-Pointing-Pointer Dynamic response of pipe conveying fluid was studied numerically. Black-Right-Pointing-Pointer The generalized integral transform technique (GITT) was applied. Black-Right-Pointing-Pointer Numerical solutions with automatic global accuracy control were obtained. Black-Right-Pointing-Pointer Excellent convergence behavior was shown. Black-Right-Pointing-Pointer Modal separation analysis was carried out and the influence of mass ratio was analyzed. - Abstract: Analysis of dynamic response of pipe conveying fluid is an important aspect in nuclear power plant design. In the present paper, dynamic response of a clamped-clamped pipe conveying fluid was solved by the generalized integral transform technique (GITT). The governing partial differential equation was transformed into a set of second-order ordinary differential equations which is then numerically solved by making use of the subroutine DIVPAG from IMSL Library. A thorough convergence analysis was performed to yield sets of reference results of the transverse deflection at different time and spanwise position. We found good agreement between the computed natural frequencies at mode 1-3 and those obtained by previous theoretical study. Besides, modal separation analysis was carried out and the influence of mass ratio on deflection and natural frequencies was qualitatively and quantitatively assessed.

  10. Dynamic Study of a Capacitive MEMS Switch with Double Clamped-Clamped Microbeams

    Directory of Open Access Journals (Sweden)

    Hatem Samaali

    2014-01-01

    Full Text Available We study a capacitive MEMS switch composed of two clamped-clamped exible microbeams. We first develop a mathematical model for the MEMS switch where the upper microbeam represents the ground transmission line and the lower one represents the central transmission line. An electrostatic force is applied between the two microbeams to yield the switch to its ON and OFF states. We derive the equations of motion of the system and associated boundary conditions and solve the static and dynamic problems using the differential quadratic method. We show that using only nine grid points gives relatively accurate results when compared to those obtained using FEM. We also examine the transient behavior of the microswitch and obtain results indicating that subsequent reduction in actuation voltage, switching time, and power consumption are expected along with relatively good RF performances. ANSYS HFSS simulator is used in this paper to extract the RF characteristics of the microswitch. HFSS simulation results show that the insertion loss is as low as −0.31 dB and that the return loss is better than −12.41 dB at 10 GHz in the ON state. At the OFF state, the isolation is lower than −23 dB in the range of 10 to 50 GHz.

  11. FEMA DFIRM Hydraulic Structures

    Data.gov (United States)

    Minnesota Department of Natural Resources — This layer and accompanying attribute table is required whenever hydraulic structures are shown in the flood profile. It is also required if levees are shown on the...

  12. Water Hydraulic Systems

    DEFF Research Database (Denmark)

    Conrad, Finn

    2005-01-01

    The paper presents research results using IT-Tools for CAD and dynamic modelling, simulation, analysis, and design of water hydraulic actuators for motion control of machines, lifts, cranes and robots. Matlab/Simulink and CATIA are used as IT-Tools. The contributions include results from on......-going research projects on fluid power and mechatronics based on tap water hydraulic servovalves and linear servo actuators and rotary vane actuators for motion control and power transmission. Development and design a novel water hydraulic rotary vane actuator for robot manipulators. Proposed mathematical...... modelling, control and simulation of a water hydraulic rotary vane actuator applied to power and control a two-links manipulator and evaluate performance. The results include engineering design and test of the proposed simulation models compared with IHA Tampere University’s presentation of research...

  13. Constant-Pressure Hydraulic Pump

    Science.gov (United States)

    Galloway, C. W.

    1982-01-01

    Constant output pressure in gas-driven hydraulic pump would be assured in new design for gas-to-hydraulic power converter. With a force-multiplying ring attached to gas piston, expanding gas would apply constant force on hydraulic piston even though gas pressure drops. As a result, pressure of hydraulic fluid remains steady, and power output of the pump does not vary.

  14. A clamp-like biohybrid catalyst for DNA oxidation

    Science.gov (United States)

    van Dongen, Stijn F. M.; Clerx, Joost; Nørgaard, Kasper; Bloemberg, Tom G.; Cornelissen, Jeroen J. L. M.; Trakselis, Michael A.; Nelson, Scott W.; Benkovic, Stephen J.; Rowan, Alan E.; Nolte, Roeland J. M.

    2013-11-01

    In processive catalysis, a catalyst binds to a substrate and remains bound as it performs several consecutive reactions, as exemplified by DNA polymerases. Processivity is essential in nature and is often mediated by a clamp-like structure that physically tethers the catalyst to its (polymeric) template. In the case of the bacteriophage T4 replisome, a dedicated clamp protein acts as a processivity mediator by encircling DNA and subsequently recruiting its polymerase. Here we use this DNA-binding protein to construct a biohybrid catalyst. Conjugation of the clamp protein to a chemical catalyst with sequence-specific oxidation behaviour formed a catalytic clamp that can be loaded onto a DNA plasmid. The catalytic activity of the biohybrid catalyst was visualized using a procedure based on an atomic force microscopy method that detects and spatially locates oxidized sites in DNA. Varying the experimental conditions enabled switching between processive and distributive catalysis and influencing the sliding direction of this rotaxane-like catalyst.

  15. The cardiovascular effects of aortic clamping and unclamping

    African Journals Online (AJOL)

    An increase in the slope of the Ea line represents an increase in ... increase. (for example as the subject exercises), stroke work ... aortic clamping is that afterload and blood pressure increase ..... nitroglycerine does not increase heart rate nor.

  16. Delay in Clamping Umbilical Cord Benefits Babies, Doctors Say

    Science.gov (United States)

    ... doctors' group said. Although delayed clamping increases the newborn's risk of jaundice that will require treatment, ACOG said there's no evidence that waiting increases the mother's risk of hemorrhage. The guidelines are to be published in the ...

  17. Planar patch-clamp force microscopy on living cells

    Energy Technology Data Exchange (ETDEWEB)

    Pamir, Evren [Center for Nano Science, Ludwig-Maximilians University, Amalienstr 54, 80799 Munich (Germany); George, Michael; Fertig, Niels [Nanion Technologies GmbH, Erzgiessereistr. 4, 80335 Munich (Germany); Benoit, Martin [Center for Nano Science, Ludwig-Maximilians University, Amalienstr 54, 80799 Munich (Germany)], E-mail: martin.benoit@physik.uni-muenchen.de

    2008-05-15

    Here we report a new combination of the patch-clamp technique with the atomic force microscope (AFM). A planar patch-clamp chip microstructured from borosilicate glass was used as a support for mechanical probing of living cells. The setup not only allows for immobilizing even a non-adherent cell for measurements of its mechanical properties, but also for simultaneously measuring the electrophysiological properties of a single cell. As a proof of principle experiment we measured the voltage-induced membrane movement of HEK293 and Jurkat cells in the whole-cell voltage clamp configuration. The results of these measurements are in good agreement with previous studies. By using the planar patch-clamp chip for immobilization, the AFM not only can image non-adhering cells, but also gets easily access to an electrophysiologically controlled cellular probe at low vibrational noise.

  18. [Time of cord clamping and neonatal complications, a prospective study].

    Science.gov (United States)

    Rincón, D; Foguet, A; Rojas, M; Segarra, E; Sacristán, E; Teixidor, R; Ortega, A

    2014-09-01

    To assess the effects of early or late clamping of the umbilical cord in term newborns, assessing the levels of hemoglobin, hematocrit, and ferritin, and their correlation with some of the complications. A prospective study of healthy newborns at term or born by dystotic or eutocic delivery in our hospital between May 2009 until May 2010. Patients were assigned according to the time of clamping, group 1 (clamping (g1: 111 mg/dl, g2: 125 mg/dl, g3: 173 mg/dl; pcord clamping is associated with an increase in hematocrit, hemoglobin and ferritin at 48 hours of life, as well as an increased risk of polycythemia present with symptoms. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  19. Choosing the wire clamp microdrive for termosonic microwelding equipments

    Directory of Open Access Journals (Sweden)

    Lanin V. L.

    2010-06-01

    Full Text Available The article describes research of three types of wire clamp microdrive for termosonic microwelding equipment, covering an expanded range microconductors from 12,5 up to 75 mm. The most preferable, in the light of their high-speed and easy-programming qualities, proved to be the mechanisms of conductor clamp with piezoelement drives and the loading system based on "voice-coil" type electromagnet.

  20. Prehospital Emergency Inguinal Clamp Controls Hemorrhage in Cadaver Model

    Science.gov (United States)

    2013-07-01

    the CRoC preassembled for quick use. The clamp compresses the casualty’s tissues and is unat- tached to things like a litter. When screwed down, it is...for use on the battlefield to control difficult bleeds in the inguinal area. Study Design The study design was a sequence of experiments of clamp...temperature 4 hours before testing. The torso was rotated onto a wood block to intubate the aorta through a left thoracotomy incision. The thoracic aorta

  1. Lotus birth, a holistic approach on physiological cord clamping.

    Science.gov (United States)

    Zinsser, Laura A

    2017-09-04

    The positive effects of delayed cord clamping (DCC) has been extensively researched. DCC means: waiting at least one minute after birth before clamping and cutting the cord or till the pulsation has stopped. With physiological clamping and cutting (PCC) the clamping and cutting can happen at the earliest after the pulsation has stopped. With a Lotus birth, no clamping and cutting of the cord is done. A woman called Clair Lotus Day imitated the holistic approach of PCC from an anthropoid ape in 1974. The chimpanzee did not separate the placenta from the newborn. The aim of this case report is to discuss and learn a different approach in the third stage of labour. Three cases of Lotus birth by human beings were observed. All three women gave birth in an out-of-hospital setting and had ambulant postnatal care. The placenta was washed, salted and herbs were put on 2-3h post partum. The placenta was wrapped in something that absorbs the moisture. The salting was repeated with a degreasing frequency depending on moistness of the placenta. On life day six all three Lotus babies experiences a natural separation of the cord. All three Lotus birth cases were unproblematic, no special incidence occurred. One should differentiate between early cord clamping (ECC), delayed cord clamping (DCC) and physiological cord clamping (PCC). Lotus birth might lead to an optimisation of the bonding and attachment. Research is needed in the areas of both PCC and Lotus birth. Copyright © 2017 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.

  2. Ventilation onset prior to umbilical cord clamping (physiological-based cord clamping) improves systemic and cerebral oxygenation in preterm lambs.

    Science.gov (United States)

    Polglase, Graeme R; Dawson, Jennifer A; Kluckow, Martin; Gill, Andrew W; Davis, Peter G; Te Pas, Arjan B; Crossley, Kelly J; McDougall, Annie; Wallace, Euan M; Hooper, Stuart B

    2015-01-01

    As measurement of arterial oxygen saturation (SpO2) is common in the delivery room, target SpO2 ranges allow clinicians to titrate oxygen therapy for preterm infants in order to achieve saturation levels similar to those seen in normal term infants in the first minutes of life. However, the influence of the onset of ventilation and the timing of cord clamping on systemic and cerebral oxygenation is not known. We investigated whether the initiation of ventilation, prior to, or after umbilical cord clamping, altered systemic and cerebral oxygenation in preterm lambs. Systemic and cerebral blood-flows, pressures and peripheral SpO2 and regional cerebral tissue oxygenation (SctO2) were measured continuously in apnoeic preterm lambs (126±1 day gestation). Positive pressure ventilation was initiated either 1) prior to umbilical cord clamping, or 2) after umbilical cord clamping. Lambs were monitored intensively prior to intervention, and for 10 minutes following umbilical cord clamping. Clamping the umbilical cord prior to ventilation resulted in a rapid decrease in SpO2 and SctO2, and an increase in arterial pressure, cerebral blood flow and cerebral oxygen extraction. Ventilation restored oxygenation and haemodynamics by 5-6 minutes. No such disturbances in peripheral or cerebral oxygenation and haemodynamics were observed when ventilation was initiated prior to cord clamping. The establishment of ventilation prior to umbilical cord clamping facilitated a smooth transition to systemic and cerebral oxygenation following birth. SpO2 nomograms may need to be re-evaluated to reflect physiological management of preterm infants in the delivery room.

  3. Ventilation onset prior to umbilical cord clamping (physiological-based cord clamping improves systemic and cerebral oxygenation in preterm lambs.

    Directory of Open Access Journals (Sweden)

    Graeme R Polglase

    Full Text Available As measurement of arterial oxygen saturation (SpO2 is common in the delivery room, target SpO2 ranges allow clinicians to titrate oxygen therapy for preterm infants in order to achieve saturation levels similar to those seen in normal term infants in the first minutes of life. However, the influence of the onset of ventilation and the timing of cord clamping on systemic and cerebral oxygenation is not known.We investigated whether the initiation of ventilation, prior to, or after umbilical cord clamping, altered systemic and cerebral oxygenation in preterm lambs.Systemic and cerebral blood-flows, pressures and peripheral SpO2 and regional cerebral tissue oxygenation (SctO2 were measured continuously in apnoeic preterm lambs (126±1 day gestation. Positive pressure ventilation was initiated either 1 prior to umbilical cord clamping, or 2 after umbilical cord clamping. Lambs were monitored intensively prior to intervention, and for 10 minutes following umbilical cord clamping.Clamping the umbilical cord prior to ventilation resulted in a rapid decrease in SpO2 and SctO2, and an increase in arterial pressure, cerebral blood flow and cerebral oxygen extraction. Ventilation restored oxygenation and haemodynamics by 5-6 minutes. No such disturbances in peripheral or cerebral oxygenation and haemodynamics were observed when ventilation was initiated prior to cord clamping.The establishment of ventilation prior to umbilical cord clamping facilitated a smooth transition to systemic and cerebral oxygenation following birth. SpO2 nomograms may need to be re-evaluated to reflect physiological management of preterm infants in the delivery room.

  4. Trend of hydraulic units

    Energy Technology Data Exchange (ETDEWEB)

    Deshimaru, Jun' ichi

    1988-11-01

    The gear, vane and piston pumps occupy a more then 90% share in the hydraulic pumps. Comparatively large pumps are mainly variable delivery piston pumps. The piston pumps are comparatively high in output density (output per unit weight), indicating the hydraulic pump in performance, and tend to become higher and higher in it. Though they are mainly 210 to 350kgf/cm/sup 2/ in rated pressure, some of them come to surpass 400kgf/cm/sup 3/ in it. While the progress in computation also requires the high speed operation, high accuracy and other severe conditions for the hydraulic units, which accordingly and increasingly intensify the requirement for hydraulic oil in abrasion resistibility, oxidation stability and response characteristics. While cavitation comes to easily occur, which considerably and disadvantageously influences hydraulic oil in life through degradation, noise level and respondingness. From now on, the development of high performance oil and study of mechanical structure are important. 19 references, 9 figures, 2 tables.

  5. Cavitation in Hydraulic Machinery

    Energy Technology Data Exchange (ETDEWEB)

    Kjeldsen, M.

    1996-11-01

    The main purpose of this doctoral thesis on cavitation in hydraulic machinery is to change focus towards the coupling of non-stationary flow phenomena and cavitation. It is argued that, in addition to turbulence, superimposed sound pressure fluctuations can have a major impact on cavitation and lead to particularly severe erosion. For the design of hydraulic devices this finding may indicate how to further limit the cavitation problems. Chapter 1 reviews cavitation in general in the context of hydraulic machinery, emphasizing the initial cavitation event and the role of the water quality. Chapter 2 discusses the existence of pressure fluctuations for situations common in such machinery. Chapter 3 on cavitation dynamics presents an algorithm for calculating the nucleation of a cavity cluster. Chapter 4 describes the equipment used in this work. 53 refs., 55 figs.,10 tabs.

  6. Hydraulics and pneumatics

    CERN Document Server

    Parr, Andrew

    2006-01-01

    Nearly all industrial processes require objects to be moved, manipulated or subjected to some sort of force. This is frequently accomplished by means of electrical equipment (such as motors or solenoids), or via devices driven by air (pneumatics) or liquids (hydraulics).This book has been written by a process control engineer as a guide to the operation of hydraulic and pneumatic systems for all engineers and technicians who wish to have an insight into the components and operation of such a system.This second edition has been fully updated to include all recent developments su

  7. Popeye Project: Hydraulic umbilical

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, K.G.; Williams, V.T.

    1996-12-31

    For the Popeye Project, the longest super-duplex hydraulic umbilical in the world was installed in the Gulf of Mexico. This paper reports on its selection and project implementation. Material selection addresses corrosion in seawater, water-based hydraulic fluid, and methanol. Five alternatives were considered: (1) carbon-steel with traditional coating and anodes, (2) carbon-steel coated with thermally sprayed aluminum, (3) carbon-steel sheathed in aluminum, (4) super-duplex, and (5) titanium. The merits and risks associated with each alternative are discussed. The manufacture and installation of the selected umbilical are also reported.

  8. Hydraulic Arm Modeling via Matlab SimHydraulics

    OpenAIRE

    Věchet, Stanislav; Krejsa, Jiří

    2009-01-01

    System modeling is a vital tool for cost reduction and design process speed up in most engineering fields. The paper is focused on modeling of hydraulic arm as a part of intelligent prosthesis project, in the form of 2DOF open kinematic chain. The arm model combines mechanical, hydraulic and electric subsystems and uses Matlab as modeling tool. SimMechanics Matlab extension is used for mechanical part modeling, SimHydraulics toolbox is used for modeling of hydraulic circuit used for actuating...

  9. HYDRAULICS, TUSCARAWAS COUNTY, OHIO, USA

    Data.gov (United States)

    Federal Emergency Management Agency, Department of Homeland Security — Hydraulic data include spatial datasets and data tables necessary for documenting the hydraulic procedures for estimating flood discharges for a flood insurance...

  10. Umbilical cord clamping. An analysis of a usual neonatological conduct.

    Science.gov (United States)

    Papagno, L

    1998-01-01

    Here we described a critical analysis of the neonatological procedure of early cord clamping, meaning this, within 40 seconds after birth. Fifty three cases are here analysed, in which this practice was not performed, but instead a late umbilical cord clamping was done after birth or after the cord had stopped beating. Variations in hematocrito values within 24 to 36 hours after birth were studied. A transitory polycithemia, with a maximum peak 12 hours post-delivery was observed. These values returned to normal levels between 24 and 36 hours after birth. K vitamin was not administered to any of the newborns. No pathology appeared related to this transitory polycithemia. In can be concluded that the late umbilical cord clamping represents no risk to the new-born and that the pathological phenomena described under these circumstances may be attributed to the increase in K vitamin dependent coagulation factors that are induced by the routinary administration of phitonadione to all normal newborns.

  11. Arterial Clamping Increases Central Renal Cryoablation Efficacy: An Animal Study

    DEFF Research Database (Denmark)

    Nonboe, Lasse Larsen; Nielsen, Tommy Kjaergaard; Høyer, Søren;

    2017-01-01

    INTRODUCTION: The minimally invasive treatment of small renal masses with cryoablation has become increasingly widespread during the past 15 years. Studies with long-term follow-up are beginning to emerge, showing good oncological control, however, tumors with a central and endophytic location seem...... to possess an increased risk of treatment failure. Such tumors are likely to be subjected to a high volume of blood giving thermal protection to the cancerous cells. Arterial clamping during freezing might reduce this effect but at the same time subject the kidney to ischemia. The aim of this study...... was to evaluate the effect of renal artery clamping during cryoablation in a porcine survival model. METHODS: Ten Danish Landrace pigs (approximately 40 kg) underwent bilateral laparoscopic cryoablation with clamping of the right renal artery during freezing. The cryoablation consisted of a standard double...

  12. [Advantage of delayed umbilical cord clamping in the newborn infant].

    Science.gov (United States)

    Menget, A; Mougey, C; Thiriez, G; Riethmuller, D

    2013-09-01

    The timing of umbilical cord clamping remains controversial. Although most maternity wards use the early clamping (5-15s), randomized studies and meta-analyses have demonstrated the benefit of delayed clamping for term and preterm newborn infants over the past 10 years. Indeed, placentofetal transfusion of 20-30 ml/kg in 2-3 min improves the iron status of term infants and prevents infant hypochromic anemia. Infant anemia is a public health problem in many developing countries. For preterm newborns, placental transfusion for 45 s or milking the cord for 15 s improves cardiovascular adaptation, with better hemodynamic stability, as well as decreased intraventricular hemorrhages, need for transfusion, and late-onset sepsis. A new look at this symbolic act is needed and professionals need to be persuaded of the importance of the "wait a minute" policy for a better physiological delivery.

  13. Using physiology to guide time to cord clamping.

    Science.gov (United States)

    Kluckow, Martin; Hooper, Stuart B

    2015-08-01

    Immediate clamping and cutting of the umbilical cord at birth has been the accepted standard of care for decades. The physiologic rationale relating umbilical cord clamping (UCC) to the events of the circulatory transition is not considered in arbitrarily recommended cord clamping times. Systematic review of early versus deferred UCC shows significant hemodynamic benefits to the deferred group. Mechanisms for this protective effect are considered in this review. The original concept of a placental transfusion with a volume load and prevention of low cardiac output relies on the physiological end point of the amount of blood transfused. The newer concept of an ordered physiological transition is increasingly supported. This model places aeration of the lungs and an increase in pulmonary blood flow back at the centre of the circulatory transition with timing of UCC being related to establishment of respiration. The need for "physiologically based" UCC is discussed. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  14. Hydraulic hoist-press

    Energy Technology Data Exchange (ETDEWEB)

    Babayev, Z.B.; Abashev, Z.V.

    1982-01-01

    The efficiency expert of the Angrenskiy production-technological administration of the production association Sredazugol A. V. Bubnov has suggested a hydraulic hoist-press for repairing road equipment which is a device consisting of lifting mechanism, press and test stand for verifying the high pressure hoses and pumps.

  15. Modelling of Hydraulic Robot

    DEFF Research Database (Denmark)

    Madsen, Henrik; Zhou, Jianjun; Hansen, Lars Henrik

    1997-01-01

    This paper describes a case study of identifying the physical model (or the grey box model) of a hydraulic test robot. The obtained model is intended to provide a basis for model-based control of the robot. The physical model is formulated in continuous time and is derived by application...

  16. Water Treatment Technology - Hydraulics.

    Science.gov (United States)

    Ross-Harrington, Melinda; Kincaid, G. David

    One of twelve water treatment technology units, this student manual on hydraulics provides instructional materials for three competencies. (The twelve units are designed for a continuing education training course for public water supply operators.) The competencies focus on the following areas: head loss in pipes in series, function loss in…

  17. Water Hydraulic Systems

    DEFF Research Database (Denmark)

    Conrad, Finn

    2005-01-01

    The paper presents research results using IT-Tools for CAD and dynamic modelling, simulation, analysis, and design of water hydraulic actuators for motion control of machines, lifts, cranes and robots. Matlab/Simulink and CATIA are used as IT-Tools. The contributions include results from on-going...

  18. New active load voltage clamp for HF-link converters

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.; Andersen, M.A.E.

    2005-07-01

    This paper proposes a new active clamp for HF-link converters, which features very high efficiency by returning the clamped energy back to the primary side through a small auxiliary converter. It also increases the reliability of HF-link converters by providing an alternative load current path during malfunctions of the secondary bidirectional bridge. The feasibility of the approach is shown on audio power amplifier prototype. New integrated magnetics design is presented that incorporates both the main power and auxiliary transformer on the same magnetic core. (au)

  19. Plasma temperature clamping in filamentation laser induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Harilal, Sivanandan S.; Yeak, J.; Phillips, Mark C.

    2015-10-19

    Ultrafast laser filament induced breakdown spectroscopy is a very promising method for remote material detection. We present characteristics of plasmas generated in a metal target by laser filaments in air. Our measurements show that the temperature of the ablation plasma is clamped along the filamentation channel due to intensity clamping in a filament. Nevertheless, significant changes in radiation intensity are noticeable, and this is essentially due to variation in the number density of emitting atoms. The present results also partly explains the reason for the occurrence of atomic plume during fs LIBS in air compared to long-pulse ns LIBS.

  20. New active load voltage clamp for HF-link converters

    DEFF Research Database (Denmark)

    Ljusev, Petar; Andersen, Michael Andreas E.

    2005-01-01

    This paper proposes a new active clamp for HF-link converters, which features very high efficiency by returning the clamped energy back to the primary side through a small auxiliary converter. It also increases the reliability of HF-link converters by providing an alternative load current path du...... during malfunctions of the secondary bidirectional bridge. The feasibility of the approach is shown on audio power amplifier prototype. New integrated magnetics design is presented that incorporates both the main power and auxiliary transformer on the same magnetic core....

  1. The problem of isotropic rectangular plate with four clamped edges

    Indian Academy of Sciences (India)

    C Erdem İmrak; Ismail Gerdemeli

    2007-06-01

    The examination of the exact solution of the governing equation of the rectangular plate is important for many reasons. This report discusses in exact solution of the governing equation of an isotropic rectangular plate with four clamped edges. A numerical method for clamped isotropic rectangular plate under distributed loads and an exact solution of the governing equation in terms of trigonometric and hyperbolic function are given. Finally, an illustrative example is given and the results are compared with those reported earlier. This method is found to be easier and effective. The results show reasonable agreement with other available results, but with a simpler and practical approach.

  2. Development of a hydraulic borehole seismic source

    Energy Technology Data Exchange (ETDEWEB)

    Cutler, R.P.

    1998-04-01

    This report describes a 5 year, $10 million Sandia/Industry project to develop an advanced borehole seismic source for use in oil and gas exploration and production. The development Team included Sandia, Chevron, Amoco, Conoco, Exxon, Raytheon, Pelton, and GRI. The seismic source that was developed is a vertically oriented, axial point force, swept frequency, clamped, reaction-mass vibrator design. It was based on an early Chevron prototype, but the new tool incorporates a number of improvements which make it far superior to the original prototype. The system consists of surface control electronics, a special heavy duty fiber optic wireline and draw works, a cablehead, hydraulic motor/pump module, electronics module, clamp, and axial vibrator module. The tool has a peak output of 7,000 lbs force and a useful frequency range of 5 to 800 Hz. It can operate in fluid filled wells with 5.5-inch or larger casing to depths of 20,000 ft and operating temperatures of 170 C. The tool includes fiber optic telemetry, force and phase control, provisions to add seismic receiver arrays below the source for single well imaging, and provisions for adding other vibrator modules to the tool in the future. The project yielded four important deliverables: a complete advanced borehole seismic source system with all associated field equipment; field demonstration surveys funded by industry showing the utility of the system; industrial sources for all of the hardware; and a new service company set up by their industrial partner to provide commercial surveys.

  3. A clamp fixture with interdigital capacitive sensor for in situ evaluation of wire insulation

    Science.gov (United States)

    Sheldon, Robert T.; Bowler, Nicola

    2014-02-01

    An interdigital capacitive sensor has been designed and optimized for testing aircraft wires by applying a quasinumerical model developed and reported previously. The sensor consists of two patches of interdigitated electrodes, connected by a long signal bus strip, that are intended to conform to two sides of an insulated wire. The electrodes are deposited using photolithography upon a 25.4-μm-thick Kapton® polyimide film. The two electrode patches are attached to the two jaws of a plastic spring-loaded clamp, with each jaw having a milled groove designed such that the electrodes conform to the curved surface of the insulated wire. An SMA connector and cable connect between the electrodes on the clamp and an LCR meter. Segments of pristine M5086/2 aircraft wire, each 10 cm long, were immersed in fluids commonly found in aircraft environments, to cause accelerated chemical degradation. The effects of Jet A fuel, deicing fluid, hydraulic fluid, aircraft cleaner, isopropyl alcohol and distilled water were studied. The frequency-dependent capacitance and dissipation factor of one pristine wire segment and of those degraded in the six fluid environments were measured within the frequency range 100 Hz to 1 MHz. Significant changes in capacitance and dissipation factor were observed for all degraded wires, compared with results for the pristine sample, suggesting the feasibility of detecting insulation degradation in the field. The results were also consistent with those of a similar experiment performed on sheets of Nylon 6, the material that comprises the outermost layer of M5086/2 wire.

  4. IVC CLAMP: infrahepatic inferior vena cava clamping during hepatectomy - a randomised controlled trial in an interdisciplinary setting

    Directory of Open Access Journals (Sweden)

    Reissfelder Christoph

    2009-10-01

    Full Text Available Abstract Background Intraoperative haemorrhage is a known predictor for perioperative outcome of patients undergoing hepatic resection. While anaesthesiological lowering of central venous pressure (CVP by fluid restriction is known to reduce bleeding during transection of the hepatic parenchyma its potential side effects remain poorly investigated. In theory it may have negative effects on kidney function and tissue perfusion and bears the risk to result in severe haemodynamic instability in case of profound intraoperative blood loss. The present randomised controlled trial evaluates efficacy and safety of infrahepatic inferior vena cava (IVC clamping as an alternative surgical technique to reduce CVP during hepatic resection. Methods/Design The proposed IVC CLAMP trial is a single-centre randomised controlled trial with a two-group parallel design. Patients and outcome-assessors are blinded for the treatment intervention. Patients undergoing elective hepatic resection due to any reason are enrolled in IVC CLAMP. All patients admitted to the Department of General-, Visceral-, and Transplant Surgery, University of Heidelberg for elective hepatic resection are consecutively screened for eligibility and written informed consent is obtained on the day before surgery. The primary objective of this trial is to assess and compare the amount of blood loss during hepatic resection in patients receiving surgical CVP reduction by clamping of the IVC as compared to anaesthesiological CVP without infrahepatic IVC clamping reduction. In addition to blood loss a set of general as well as surgical variables are analysed. Discussion This is a randomised controlled patient and observer blinded two-group parallel trial designed to assess efficacy and safety of infrahepatic IVC clamping during elective hepatectomy. Trial registration ClinicalTrials NCT00732979

  5. COMPARISON OF VIBRATION PERFORMANCE OF A SANDWICH CLAMPED-CLAMPED BEAM WITH MAGNETS VERSUS CONVENTIONAL CONSTRAINED DAMPING TREATMENTS

    Institute of Scientific and Technical Information of China (English)

    ZhengHuiming; HeZeng; LiMing; ZhaoGaoyu

    2004-01-01

    This paper investigates how the magnetic constrained layer damping (MCLD) treatment suppresses the displacement and acceleration resonant peak of a clamped-clamped beam. Because MCLI) treatment reduces input work and gives more dissipation energy, the vibration from external excitation can be effectively suppressed.The vibration reduction effects of MCLD and other conventional constrained damping treatments are also evaluated. In many cases, using MCLD treatments can yield smaller displacement and acceleration resonant peak especially in mode 1 compared to the other treatments without greatly changing the natural frequencies of the base beam.

  6. Hydraulic manipulator research at ORNL

    Energy Technology Data Exchange (ETDEWEB)

    Kress, R.L.; Jansen, J.F. [Oak Ridge National Lab., TN (United States); Love, L.J. [Oak Ridge Inst. for Science and Education, TN (United States)

    1997-03-01

    Recently, task requirements have dictated that manipulator payload capacity increase to accommodate greater payloads, greater manipulator length, and larger environmental interaction forces. General tasks such as waste storage tank cleanup and facility dismantlement and decommissioning require manipulator life capacities in the range of hundreds of pounds rather than tens of pounds. To meet the increased payload capacities demanded by present-day tasks, manipulator designers have turned once again to hydraulics as a means of actuation. In order to successfully design, build, and deploy a new hydraulic manipulator (or subsystem), sophisticated modeling, analysis, and control experiments are usually needed. Oak Ridge National Laboratory (ORNL) has a history of projects that incorporate hydraulics technology, including mobile robots, teleoperated manipulators, and full-scale construction equipment. In addition, to support the development and deployment of new hydraulic manipulators, ORNL has outfitted a significant experimental laboratory and has developed the software capability for research into hydraulic manipulators, hydraulic actuators, hydraulic systems, modeling of hydraulic systems, and hydraulic controls. The purpose of this article is to describe the past hydraulic manipulator developments and current hydraulic manipulator research capabilities at ORNL. Included are example experimental results from ORNL`s flexible/prismatic test stand.

  7. INOVASI SAMBUNGAN MEKANIS MENGGUNAKAN CLAMP BAJA UNTUK TULANGAN BETON

    Directory of Open Access Journals (Sweden)

    Parmo

    2015-12-01

    Full Text Available In the last few years, Indonesian urban growth has tends to be lead to the overground space. This was caused by the significant population increasement the lackness of land availability. The phenomenon is also marked with the increasing number of high-rise buildings and skyscrapers. However, high-rise buildings and skyscrapers have the potential dangers against earthquakes, even more Indonesia lay on an earthquake-prone areas. There are two main things that need to be considered in the planning of earthquake-resistant buildings, which is strength and ductility. Deformation capability and the connection strength between the reinforcement taken into consideration in the design of earthquake-resistant structures. From the steel clamp tensile test results for D13’s mechanical connection reinforcement, it gained 270.69 Mpa for yield strength, 351.45 MPa for ultimate tensile strength and 4757 kg for maximum load with 40% elongation. As for the D16’s mechanical connection reinforcement gained 217.80 MPa for yield strength, 327 605 MPa for ultimate tensile strength and 6717 kg for maximum load with 32% elongation. This study uses two pieces of steel clamp, but in order to obtain a better result then it need to be add more clamps while increasing the steel clamp material quality.

  8. Do not overlook an umbilical cord hernia before clamping.

    Science.gov (United States)

    Cizmeci, Mehmet Nevzat; Kanburoglu, Mehmet Kenan; Akelma, Ahmet Zulfikar; Tatli, Mustafa Mansur

    2013-08-01

    An umbilical cord hernia is a rare midline abdominal defect. These masses may be easily overlooked at birth, which may result in an intestinal injury due to careless proximal application of the cord clamp. Herein, we present a newborn infant with an umbilical cord hernia who was managed by primary closure of the lesion.

  9. A piezoelectric vibration harvester based on clamped-guided beams

    NARCIS (Netherlands)

    Wang, Z.; Matova, S.; Elfrink, R.; Jambunathan, M.; Nooijer, C. de; Schaijk, R. van; Vullers, R.J.M.

    2012-01-01

    The paper addresses the design, modeling, fabrication and experimental results of a piezoelectric energy harvester based on clamped-guided beams. The design is featured by shorter mass displacement and higher reliability than cantilever beams. Two separate sets of capacitors allow exploiting both te

  10. Remotely Adjustable Hydraulic Pump

    Science.gov (United States)

    Kouns, H. H.; Gardner, L. D.

    1987-01-01

    Outlet pressure adjusted to match varying loads. Electrohydraulic servo has positioned sleeve in leftmost position, adjusting outlet pressure to maximum value. Sleeve in equilibrium position, with control land covering control port. For lowest pressure setting, sleeve shifted toward right by increased pressure on sleeve shoulder from servovalve. Pump used in aircraft and robots, where hydraulic actuators repeatedly turned on and off, changing pump load frequently and over wide range.

  11. Undular Hydraulic Jump

    Directory of Open Access Journals (Sweden)

    Oscar Castro-Orgaz

    2015-04-01

    Full Text Available The transition from subcritical to supercritical flow when the inflow Froude number Fo is close to unity appears in the form of steady state waves called undular hydraulic jump. The characterization of the undular hydraulic jump is complex due to the existence of a non-hydrostatic pressure distribution that invalidates the gradually-varied flow theory, and supercritical shock waves. The objective of this work is to present a mathematical model for the undular hydraulic jump obtained from an approximate integration of the Reynolds equations for turbulent flow assuming that the Reynolds number R is high. Simple analytical solutions are presented to reveal the physics of the theory, and a numerical model is used to integrate the complete equations. The limit of application of the theory is discussed using a wave breaking condition for the inception of a surface roller. The validity of the mathematical predictions is critically assessed using physical data, thereby revealing aspects on which more research is needed

  12. Hydraulic System Design of Hydraulic Actuators for Large Butterfly Valves

    OpenAIRE

    HUANG, Ye; Liu, Changsheng; Shiongur Bamed

    2014-01-01

    Hydraulic control systems of butterfly valves are presently valve-controlled and pump-controlled. Valve-controlled hydraulic systems have serious power loss and generate much heat during throttling. Pump-controlled hydraulic systems have no overflow or throttling losses but are limited in the speed adjustment of the variable-displacement pump, generate much noise, pollute the environment, and have motor power that does not match load requirements, resulting in low efficiency under...

  13. Hydraulic System Design of Hydraulic Actuators for Large Butterfly Valves

    Directory of Open Access Journals (Sweden)

    Ye HUANG

    2014-09-01

    Full Text Available Hydraulic control systems of butterfly valves are presently valve-controlled and pump-controlled. Valve-controlled hydraulic systems have serious power loss and generate much heat during throttling. Pump-controlled hydraulic systems have no overflow or throttling losses but are limited in the speed adjustment of the variable-displacement pump, generate much noise, pollute the environment, and have motor power that does not match load requirements, resulting in low efficiency under light loads and wearing of the variable-displacement pump. To overcome these shortcomings, this article designs a closed hydraulic control system in which an AC servo motor drives a quantitative pump that controls a spiral swinging hydraulic cylinder, and analyzes and calculates the structure and parameters of a spiral swinging hydraulic cylinder. The hydraulic system adjusts the servo motor’s speed according to the requirements of the control system, and the motor power matches the power provided to components, thus eliminating the throttling loss of hydraulic circuits. The system is compact, produces a large output force, provides stable transmission, has a quick response, and is suitable as a hydraulic control system of a large butterfly valve.

  14. Four- year thyroidectomy procedures: Ligasure Vs. clamp & tie

    Directory of Open Access Journals (Sweden)

    Pazoki AR

    2010-01-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: The electrothermal bipolar vessel sealing system is an adjunct to the hemostatic technique, which has been successfully used in many abdominal operation, recently made available to thyroid surgery. The purpose of this was compare the outcomes of new hemostatic technique with traditional method of clamp and tie."n"nMethods: In this retrospective cross-sectional study has been done in surgery's wards of Milad & Rasul- Akram hospitals in Tehran, Iran. During three- year period between 2005-2008 all patients with different kind of pathology that need operation were assessed. Time duration of surgery and hospital stay and post surgery complication in two group, ligasure (n=45 and clamp & tie (n=145 were compared with each others."n"nResults: No difference was seen between two groups in time duration of surgery. Significant difference was seen in hospital stay and complications of surgery. Time of operation in Ligasure group was 132/22 minute and in clamp and tie group was 130/10 minute. There was found significant difference in duration of hospital stay and postoperative complication. Hypocalcemia were seen in two and 24 cases in Ligasure and Clamp & Tie group, respectively (p<0.05. Hospital stay was 2

  15. Timing of umbilical cord clamping: effect on iron endowment of the newborn and later iron status.

    Science.gov (United States)

    Chaparro, Camila M

    2011-11-01

    The optimal timing of umbilical cord clamping has been debated in the scientific literature for at least the last century, when cord clamping practices shifted from delayed towards immediate clamping. Recent research provides evidence for the beneficial effect of delayed cord clamping on infant iron status. The present review describes the physiological basis for the impact of cord clamping time on total body iron at birth and the relationship between birth body iron, as affected by cord clamping time, and iron status later in infancy. This research is discussed in the context of current clamping practices, which tend towards early cord clamping in most settings, as well as the high levels of anemia present in young infants in many countries worldwide. © 2011 International Life Sciences Institute.

  16. 一种注塑机锁模系统的理论计算与模拟分析%A Clamping System for Injection Machine

    Institute of Scientific and Technical Information of China (English)

    曾广胜; 瞿金平; 江太君; 刘跃军

    2012-01-01

    A clamping system based on thermal expansion of metals was developed based on the characteristics and disadvantages of elbow bar-type,hydraulic direct compressed and servo motor direct compressed clamping systems for injection machine.The material performance,heating and cooling process and their efficiency of this clamping system were calculated.And then the working performance of this clamping system on specific operating condition was simulated with Finite Element Analysis software ANSYS 10.0.It proved this new mechanism to be an accurate,stable,safe,pollution-free,rapid and efficient clamping mechanism.%在肘杆式、液压直压式、伺服电机直压式三种注塑机锁模机构优缺点基础上提出了利用金属材料热胀冷缩性质实现模具锁紧的锁模系统。分别从材料选择、加热及冷却过程等方面对该系统进行了理论计算,最后利用ANSYS10.0有限元分析软件对该系统在特定工况下的工作性能进行了全真模拟分析。结果表明,该锁模系统是一种精密、稳定、安全、无污染、快速高效的锁模系统。

  17. Modelling of Hydraulic Robot

    DEFF Research Database (Denmark)

    Madsen, Henrik; Zhou, Jianjun; Hansen, Lars Henrik

    1997-01-01

    This paper describes a case study of identifying the physical model (or the grey box model) of a hydraulic test robot. The obtained model is intended to provide a basis for model-based control of the robot. The physical model is formulated in continuous time and is derived by application...... of the laws of physics on the system. The unknown (or uncertain) parameters are estimated with Maximum Likelihood (ML) parameter estimation. The identified model has been evaluated by comparing the measurements with simulation of the model. The identified model was much more capable of describing the dynamics...... of the system than the deterministic model....

  18. Hydraulic mining method

    Science.gov (United States)

    Huffman, Lester H.; Knoke, Gerald S.

    1985-08-20

    A method of hydraulically mining an underground pitched mineral vein comprising drilling a vertical borehole through the earth's lithosphere into the vein and drilling a slant borehole along the footwall of the vein to intersect the vertical borehole. Material is removed from the mineral vein by directing a high pressure water jet thereagainst. The resulting slurry of mineral fragments and water flows along the slant borehole into the lower end of the vertical borehole from where it is pumped upwardly through the vertical borehole to the surface.

  19. Spinning hydraulic jump

    Science.gov (United States)

    Abderrahmane, Hamid; Kasimov, Aslan

    2013-11-01

    We report an experimental observation of a new symmetry breaking of circular hydraulic jump into a self-organized structure that consists of a spinning polygonal jump and logarithmic-spiral waves of fluid elevation downstream. The waves are strikingly similar to spiral density waves in galaxies. The fluid flow exhibits counterparts of salient morphological features of galactic flows, in particular the outflow from the center, jets, circum-nuclear rings, gas inflows toward the galactic center, and vortices. The hydrodynamic instability revealed here may have a counterpart that plays a role in the formation and sustainability of spiral arms in galaxies.

  20. Gigaseal formation in patch clamping with applications of nanotechnology

    CERN Document Server

    Malboubi, Majid

    2014-01-01

    This book presents an investigation of gigaseal formation using micro/nanotechnology. The aims of the book are twofold. First, it explains the mechanisms of gigaseal formation using the latest discoveries. Second, it provides practical techniques for frequent formation of high resistance seals. The formation of a high-resistance electrical seal, also known as a gigaseal, between a cell membrane and a glass micropipette tip is essential in patch-clamp experiments. Even though four decades have passed since the introduction of the patch-clamping technique by Neher and Sakmann, gigaseal formation remains an obstacle in developing the high-throughput ion channel screening systems required by the pharmaceutical industry. Here the authors share their latest methods for achieving gigaseal formation and describe techniques that are highly desirable at both research and industrial levels. Nanotechnology has been found to be a powerful tool for studying and modifying glass micropipettes and in tackling the problem of g...

  1. A new configuration for multilevel converters with diode clamped topology

    DEFF Research Database (Denmark)

    Nami, A.; Zare, F.; Ledwich, G.

    2008-01-01

    of load changes which can avoid neutral point balancing problem in such converters. In addition, the presented topology is suitable for renewable energy systems to boost the low rectified output-voltage. In order to verify the proposed topology, steady state analysis, modelling and simulations are carried......Due to the increased use of renewable energy and power elctronic applications, more multilevel converters (MLC) are developed. A Neutral Point Clamped (NPC) inverter is one of the most used multilevel topologies for wind turbine (WT) and photovoltaic (PV) applications. One of the most crucial...... points in this type of converter is dc-voltage control. In this paper, a novel multi output dc-dc converter connected to a diode clamped topology is presented. This converter, for a given duty cycles, is able to regulate the capacitor voltage to provide an appropriate input voltage for NPC regardless...

  2. Active energy recovery clamping circuit to improve the performance of power converters

    Energy Technology Data Exchange (ETDEWEB)

    Whitaker, Bret; Barkley, Adam

    2017-05-09

    A regenerative clamping circuit for a power converter using clamping diodes to transfer charge to a clamping capacitor and a regenerative converter to transfer charge out of the clamping capacitor back to the power supply input connection. The regenerative converter uses a switch connected to the midpoint of a series connected inductor and capacitor. The ends of the inductor and capacitor series are connected across the terminals of the power supply to be in parallel with the power supply.

  3. Timing of umbilical cord clamping and neonatal haematological status.

    Science.gov (United States)

    Jaleel, Riffat; Deeba, Farah; Khan, Ayesha

    2009-07-01

    To determine the effect of delayed umbilical cord clamping on Hb (haemoglobin) and bilirubin levels of neonates and to identify newborn babies with anaemia and refer them for treatment. This Randomized Controlled Trial was conducted in the Department of Obstetrics and Gynaecology, Unit V, Dow Medical College and Lyari General Hospital and Department of Pathology, Lyari General Hospital, between 1st November, 2006 and 15th July, 2007. Patients admitted to labour ward were selected according to inclusion criteria of the study. They were randomly allocated to 2 groups. Group A included women in whom umbilical cord was clamped immediately after birth. In Group B, clamping was delayed until cessation of pulsations in the cord. After cutting the cord, sample of blood was collected from the cut end of cord of the newborn for Hb and bilirubin. After 6 hours of birth, another sample of blood was drawn from antecubital vein for serum bilirubin. Samples were sent to laboratory for analysis. All data were entered and analyzed using SPSS version 11. Two hundred women were studied, 100 in each of the 2 groups. Mean maternal Hb was 9.75 g/dl in Group A and 9.95 g/dl in Group B. The average neonatal Hb was 14.1 g/dl in Group A and 15.2 g/dl in Group B (p = 0.008). In all 49% neonates in Group A and 37% in Group B had Hb umbilical cord clamping at birth seems to be safe and can be expected to reduce the prevalence of anaemic newborn babies in our community.

  4. Indentation metrology of clamped, ultra-thin elastic sheets

    OpenAIRE

    Vella, Dominic; Davidovitch, Benny

    2017-01-01

    We study the indentation of ultrathin elastic sheets clamped to the edge of a circular hole. This classical setup has received considerable attention lately, being used by various experimental groups as a probe to measure the surface properties and stretching modulus of thin solid films. Despite the apparent simplicity of this method, the geometric nonlinearity inherent in the mechanical response of thin solid objects renders the analysis of the resulting data a nontrivial task. Importantly, ...

  5. 46 CFR 28.880 - Hydraulic equipment.

    Science.gov (United States)

    2010-10-01

    ... hydraulic equipment and the adjacent work area. Protection shall be afforded to the operator of hydraulic... 46 Shipping 1 2010-10-01 2010-10-01 false Hydraulic equipment. 28.880 Section 28.880 Shipping... INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.880 Hydraulic equipment. (a) Each hydraulic system must...

  6. POLYCYTHEMIA RISK IN NEONATES WITH DELAYED CORD CLAMPING

    Directory of Open Access Journals (Sweden)

    I Gusti Agung Ayu Sri Wulandari Pramana

    2013-07-01

    Full Text Available Normal 0 false false false EN-US X-NONE X-NONE Delayed Cord Clamping is still a controversial issue in the world of medicine. Until recently, the perfect times to do a Delayed Cord Clamping in various parts of the Earth in the world are still very diverse. There are a few things that became a major concern associated with Delayed Cord Clamping, one of which is the increase in blood volume due to an increase in the number of erythrocytes which led to occurrence of neonatal polycythemia which later can lead to various complications. Polycythemia in neonates is a situation where the value of venous blood hematokrit over 65% (0.65 or the amount of hemoglobin more than 22gr/Dl. However, to date the data from a variety of the latest research and analysis of the studies mention that the polycythemia that occurs in neonates with umbilical cord pinching the flush delay was mild polycythemia that can improve after 48 to 72 hours after the baby is born.

  7. Cleaning patch-clamp pipettes for immediate reuse

    Science.gov (United States)

    Kolb, I.; Stoy, W. A.; Rousseau, E. B.; Moody, O. A.; Jenkins, A.; Forest, C. R.

    2016-01-01

    Patch-clamp recording has enabled single-cell electrical, morphological and genetic studies at unparalleled resolution. Yet it remains a laborious and low-throughput technique, making it largely impractical for large-scale measurements such as cell type and connectivity characterization of neurons in the brain. Specifically, the technique is critically limited by the ubiquitous practice of manually replacing patch-clamp pipettes after each recording. To circumvent this limitation, we developed a simple, fast, and automated method for cleaning glass pipette electrodes that enables their reuse within one minute. By immersing pipette tips into Alconox, a commercially-available detergent, followed by rinsing, we were able to reuse pipettes 10 times with no degradation in signal fidelity, in experimental preparations ranging from human embryonic kidney cells to neurons in culture, slices, and in vivo. Undetectable trace amounts of Alconox remaining in the pipette after cleaning did not affect ion channel pharmacology. We demonstrate the utility of pipette cleaning by developing the first robot to perform sequential patch-clamp recordings in cell culture and in vivo without a human operator. PMID:27725751

  8. MEMS-based clamp with a passive hold function for precision position retaining of micro manipulators

    NARCIS (Netherlands)

    Brouwer, D.M.; Jong, de B.R.; Boer, de M.J.; Jansen, H.V.; Dijk, van J.; Krijnen, G.J.M.; Soemers, H.M.J.R.

    2009-01-01

    In this paper the design, modeling and fabrication of a precision MEMS-based clamp with a relatively large clamping force are presented. The purpose of the clamp is to mechanically fix a six-degree-of-freedom (DOF) MEMS-based sample manipulator (Brouwer et al J. Int. Soc. Precis. Eng. Nanotechnol. s

  9. MEMS-based clamp with a passive hold function for precision position retaining of micromanipulators

    NARCIS (Netherlands)

    Brouwer, Dannis Michel; de Jong, B.R.; de Boer, Meint J.; Jansen, Henricus V.; van Dijk, Johannes A.G.M.; van Dijk, Johannes; Krijnen, Gijsbertus J.M.; Soemers, Herman

    2009-01-01

    In this paper the design, modeling and fabrication of a precision MEMS-based clamp with arelatively large clamping force are presented. The purpose of the clamp is to mechanically fixa six-degree-of-freedom (DOF) MEMS-based sample manipulator (Brouwer et al J. Int. Soc. Precis. Eng. Nanotechnol. sub

  10. File list: Oth.ALL.10.Clamp.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.ALL.10.Clamp.AllCell dm3 TFs and others Clamp All cell types SRX159170,SRX15917...2,SRX159174,SRX159166,SRX159173 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.ALL.10.Clamp.AllCell.bed ...

  11. File list: Oth.ALL.05.Clamp.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.ALL.05.Clamp.AllCell dm3 TFs and others Clamp All cell types SRX159172,SRX15917...0,SRX159174,SRX159166,SRX159173 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.ALL.05.Clamp.AllCell.bed ...

  12. File list: Oth.CeL.10.Clamp.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.CeL.10.Clamp.AllCell dm3 TFs and others Clamp Cell line SRX159170,SRX159172,SRX...159174,SRX159166,SRX159173 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.CeL.10.Clamp.AllCell.bed ...

  13. File list: Oth.CeL.20.Clamp.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.CeL.20.Clamp.AllCell dm3 TFs and others Clamp Cell line SRX159172,SRX159170,SRX...159174,SRX159166,SRX159173 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.CeL.20.Clamp.AllCell.bed ...

  14. File list: Oth.ALL.50.Clamp.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.ALL.50.Clamp.AllCell dm3 TFs and others Clamp All cell types SRX159172,SRX15917...0,SRX159174,SRX159166,SRX159173 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.ALL.50.Clamp.AllCell.bed ...

  15. File list: Oth.ALL.20.Clamp.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.ALL.20.Clamp.AllCell dm3 TFs and others Clamp All cell types SRX159172,SRX15917...0,SRX159174,SRX159166,SRX159173 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.ALL.20.Clamp.AllCell.bed ...

  16. File list: Oth.CeL.05.Clamp.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.CeL.05.Clamp.AllCell dm3 TFs and others Clamp Cell line SRX159172,SRX159170,SRX...159174,SRX159166,SRX159173 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.CeL.05.Clamp.AllCell.bed ...

  17. The early effects of delayed cord clamping in term infants born to Libyan mothers

    NARCIS (Netherlands)

    Emhamed, Musbah Omar; van Rheenen, Patrick; Brabin, Bernard J

    2004-01-01

    This study was conducted to evaluate the haematological effects of the timing of umbilical cord clamping in term infants 24 h after birth in Libya. Mother-infant pairs were randomly assigned to early cord clamping (within 10s after delivery) or delayed clamping (after the cord stopped pulsating). Ma

  18. Applied hydraulic transients

    CERN Document Server

    Chaudhry, M Hanif

    2014-01-01

    This book covers hydraulic transients in a comprehensive and systematic manner from introduction to advanced level and presents various methods of analysis for computer solution. The field of application of the book is very broad and diverse and covers areas such as hydroelectric projects, pumped storage schemes, water-supply systems, cooling-water systems, oil pipelines and industrial piping systems. Strong emphasis is given to practical applications, including several case studies, problems of applied nature, and design criteria. This will help design engineers and introduce students to real-life projects. This book also: ·         Presents modern methods of analysis suitable for computer analysis, such as the method of characteristics, explicit and implicit finite-difference methods and matrix methods ·         Includes case studies of actual projects ·         Provides extensive and complete treatment of governed hydraulic turbines ·         Presents design charts, desi...

  19. Investigation of the Dynamics of a Clamped-Clamped Microbeam Near the Third Mode Using a Partial Electrode

    KAUST Repository

    Masri, Karim M.

    2014-08-17

    We present an investigation of the dynamics of a clamped-clamped microbeam excited electrostatically near its third mode. To maximize the response at the third mode, a partial electrode configuration is utilized. A multi-mode Galerkin method is used to develop a reduced order model (ROM) of the beam. A shooting method to find the periodic motion is utilized to generate frequency response curves. The curves show hardenining behavior and dynamic pull-in. We show that the dynamic amplitude of the partial configuration is higher than that of a full electrode configuration. These results are promising for the use of higher-order modes for mass detection and for ultra sensitive resonant sensors.

  20. Hydraulic rams; a comparative investigation

    NARCIS (Netherlands)

    Tacke, J.H.P.M.

    1988-01-01

    A mathematical model describing the essential features of hydraulic ram operation is developed in order to clarify the possibilities and limitations of the ram relative to its site and its adjustments. The model distinguishes three different periods in the pumping cycle of the hydraulic ram: acceler

  1. Hydraulics. FOS: Fundamentals of Service.

    Science.gov (United States)

    John Deere Co., Moline, IL.

    This manual on hydraulics is one of a series of power mechanics texts and visual aids for training in the servicing of agricultural and industrial machinery. Focus is on oil hydraulics. Materials provide basic information and illustrations for use by vocational students and teachers as well as shop servicemen and laymen. The twelve chapters focus…

  2. Timing of umbilical cord clamping: new thoughts on an old discussion.

    Science.gov (United States)

    Arca, Gemma; Botet, Francesc; Palacio, Montse; Carbonell-Estrany, Xavier

    2010-11-01

    The optimal time to clamp the umbilical cord in preterm and full-term neonates after birth continues to be a matter of debate. A review of randomised controlled trials comparing the effects of early versus late cord clamping on maternal and infant outcomes was performed to assess data in favor of immediate or delayed clamping. Although there is no conclusive evidence, delayed cord clamping seems to be beneficial in preterm and full-term neonates without compromising the initial postpartum adaptation phase or affecting the mother in the short term. However, further randomised clinical studies are needed to confirm the benefits of delayed cord clamping.

  3. Hydraulic Stability of Accropode Armour

    DEFF Research Database (Denmark)

    Jensen, T.; Burcharth, H. F.; Frigaard, Peter

    , and to assess the influence of core permeability on the hydraulic stability of Accropodes. Two structures were examined, one with a relatively permeable core and one with a relatively impermeable core. In November/December 1995, Ph.D.-student Marten Christensen carried out the model tests on the structure...... with permeable core (crushed granite with a gradation of 5-8 mm). The outcome of this study is described in "Hydraulic Stability of Single-Layer Dolos and Accropode Armour Layers" by Christensen & Burcharth (1995). In January/February 1996, Research Assistant Thomas Jensen carried out a similar study......The present report describes the hydraulic model tests of Accropode armour layers carried out at the Hydraulics Laboratory at Aalborg University from November 1995 through March 1996. The objective of the model tests was to investigate the hydraulic stability of Accropode armour layers...

  4. Hydraulic Stability of Accropode Armour

    DEFF Research Database (Denmark)

    Jensen, T.; Burcharth, H. F.; Frigaard, Peter

    , and to assess the influence of core permeability on the hydraulic stability of Accropodes. Two structures were examined, one with a relatively permeable core and one with a relatively impermeable core. In November/December 1995, Ph.D.-student Marten Christensen carried out the model tests on the structure...... with permeable core (crushed granite with a gradation of 5-8 mm). The outcome of this study is described in "Hydraulic Stability of Single-Layer Dolos and Accropode Armour Layers" by Christensen & Burcharth (1995). In January/February 1996, Research Assistant Thomas Jensen carried out a similar study......The present report describes the hydraulic model tests of Accropode armour layers carried out at the Hydraulics Laboratory at Aalborg University from November 1995 through March 1996. The objective of the model tests was to investigate the hydraulic stability of Accropode armour layers...

  5. Hydraulic Yaw System

    DEFF Research Database (Denmark)

    Stubkier, Søren; Pedersen, Henrik C.; Mørkholt, M.

    As wind turbines increase in size, combined with increased lifetime demands, new methods for load reduction needs to be examined. One method is to make the yaw system of the turbine soft/flexible and hereby dampen the loads to the system, which is the focus of the current paper. By utilizing...... the HAWC2 aeroelastic code and an extended model of the NREL 5MW turbine combined with a simplified linear model of the turbine, the parameters of the soft yaw system are optimized to reduce loading in critical components. Results shows that a significant reduction in fatigue and extreme loads to the yaw...... system and rotor shaft when utilizing the soft yaw drive concept compared to the original stiff yaw system. The physical demands of the hydraulic yaw system are furthermore examined for a life time of 20 years. Based on the extrapolated loads, the duty cycles show that it is possible to construct...

  6. Electro Hydraulic Hitch Control

    DEFF Research Database (Denmark)

    Hansen, M. R.; Andersen, T. O.; Nielsen, B.

    2003-01-01

    system for agricultural applications and driving for transportation. During tranport phases, the lack of suspension causes the vehicle to bounce and pitch, and makes it difficalt to control. Many systems have been proposed to cope with the oscillatory behavior, and different solutions exist. Common......This paper present and discusses R&D results on electro hydraulic hitch control for off-road vehicle, in particular active damping of oscillation occuring on tractors. The research deals with analysis and control of the oscillations occuring on tractors which are design without any susspection...... for most of the systems are that they operate on the hydrailc actuators generally providing the motive forces for moving the implement and/or attachment, typically a plough. The basic idea and physical working principle are to use the implement, moveable relative to the vehicle, as a damper mass. The paper...

  7. Clamping stiffness and its influence on load distribution between paired internal spinal fixation devices.

    Science.gov (United States)

    Rohlmann, A; Calisse, J; Bergmann, G; Radvan, J; Mayer, H M

    1996-06-01

    The load distribution between two internal spinal fixation devices depends, besides other factors, on their stiffness. The stiffness ranges were determined experimentally for the clamps of the AO internal fixator with lateral nut and with posterior nut as well as for the clamps of the SOCON fixator. The stiffness of eight devices each differed by a factor of 3.1 for the clamp with lateral nut, by a factor of 1.5 for the clamp with posterior nut, and by a factor of 1.4 for the clamp of the SOCON fixator. For the AO clamp with lateral nut, the influence of the nut-tightening torque on the stiffness was determined. Using instrumented internal spinal fixation devices mounted to plastic vertebrae and simulating a corpectomy, the load distribution between the implants was measured for different tightening torques. It could be shown that, for the AO internal fixator whose clamps have a lateral nut, a nut-tightening torque > 5 Nm has only a negligible influence on load-sharing between the implants. Tooth damage occurs when the teeth of the clamp body and clamping jaw of the clamp with lateral nut do not gear together exactly, which leads to changes in the clamping stiffness and load-sharing between the two implants.

  8. The timing of cord clamping and oxidative stress in term newborns.

    Science.gov (United States)

    Díaz-Castro, Javier; Florido, Jesus; Kajarabille, Naroa; Garrido-Sánchez, Maria; Padilla, Carmen; de Paco, Catalina; Navarrete, Luis; Ochoa, Julio J

    2014-08-01

    Clamping and cutting of the umbilical cord is the most prevalent of all operations, but the optimal timing of cord clamping is controversial, with different timings offering advantages and disadvantages. This study, for the first time, compares the influence of early and late cord clamping in correlation with oxidative stress and inflammation signaling, Because cord clamping timing may have a significant influence on placenta-to-infant blood transfer, thereby modifying oxygenation of maternal and fetal tissues, and on the transfer of inflammatory mediators throughout the placenta. Sixty-four pregnant subjects were selected at the Gynecology and Obstetrics Services Department of the Clinico San Cecilio Hospital, Granada, Spain, based on disease-free women who experienced a normal course of pregnancy and a spontaneous, vaginal, single delivery. Half of the subjects had deliveries with early-clamped newborn infants (at 10 s), and the other half had late-clamped deliveries (at 2 min). Erythrocyte catalase activity was significantly greater in the late-clamped group than in the early-clamped group (P umbilical vein and P clamped group compared with the early-clamped group (P cord clamping, produced by an increase in antioxidant capacity and moderation of the inflammatory-mediated effects induced during delivery of term neonates. Copyright © 2014 by the American Academy of Pediatrics.

  9. Umbilical cord clamping at birth--practice in Norwegian maternity wards.

    Science.gov (United States)

    Lundberg, Camilla; Øian, Pål; Klingenberg, Claus

    2013-11-26

    The timing and practice used for umbilical cord clamping of neonates are controversial internationally as well as in Norway. We therefore wished to investigate routines and practices for umbilical cord clamping of neonates in Norway. A web-based questionnaire was sent to heads of departments of all maternity wards in Norway (n = 52). They were asked about their practice with regard to umbilical cord clamping of neonates and whether written routines had been prepared for this purpose. We defined early umbilical cord clamping as immediate or within 30 seconds and late clamping as ≥ 1 minute or not until pulsation in the umbilical cord had ceased. Fifty (96%) of the maternity institutions returned a completed questionnaire. Twelve institutions (24%) reported to clamp the umbilical cord of full-term neonates early, and 38 (76%) reported to practise late clamping. Nineteen maternity wards (38%) followed written routines for umbilical cord clamping of full-term neonates, and among these, early umbilical cord clamping was practised in nine (47%). In the 31 maternity wards that had no written routines, early umbilical cord clamping was practised in three (10%). Twenty-seven of the maternity wards reported that the child is placed on the maternal abdomen before clamping of the umbilical cord, 14 reported that the child commonly is held below the introitus before umbilical cord clamping, and the rest did not report any consistent practice. There is wide variation in the practice for umbilical cord clamping in Norwegian maternity wards, many of which have no written guidelines. We argue that national guidelines for umbilical cord clamping of neonates should be established.

  10. Clamped seismic metamaterials: ultra-low frequency stop bands

    Science.gov (United States)

    Achaoui, Y.; Antonakakis, T.; Brûlé, S.; Craster, R. V.; Enoch, S.; Guenneau, S.

    2017-06-01

    The regularity of earthquakes, their destructive power, and the nuisance of ground vibration in urban environments, all motivate designs of defence structures to lessen the impact of seismic and ground vibration waves on buildings. Low frequency waves, in the range 1-10 Hz for earthquakes and up to a few tens of Hz for vibrations generated by human activities, cause a large amount of damage, or inconvenience; depending on the geological conditions they can travel considerable distances and may match the resonant fundamental frequency of buildings. The ultimate aim of any seismic metamaterial, or any other seismic shield, is to protect over this entire range of frequencies; the long wavelengths involved, and low frequency, have meant this has been unachievable to date. Notably this is scalable and the effects also hold for smaller devices in ultrasonics. There are three approaches to obtaining shielding effects: bragg scattering, locally resonant sub-wavelength inclusions and zero-frequency stop-band media. The former two have been explored, but the latter has not and is examined here. Elastic flexural waves, applicable in the mechanical vibrations of thin elastic plates, can be designed to have a broad zero-frequency stop-band using a periodic array of very small clamped circles. Inspired by this experimental and theoretical observation, all be it in a situation far removed from seismic waves, we demonstrate that it is possible to achieve elastic surface (Rayleigh) wave reflectors at very large wavelengths in structured soils modelled as a fully elastic layer periodically clamped to bedrock. We identify zero frequency stop-bands that only exist in the limit of columns of concrete clamped at their base to the bedrock. In a realistic configuration of a sedimentary basin 15 m deep we observe a zero frequency stop-band covering a broad frequency range of 0-30 Hz.

  11. Accelerated commutation for passive clamp isolated boost converters

    OpenAIRE

    2002-01-01

    An efficient and cost effective bidirectional DC/DC converter reduces switch voltage stress via accelerated commutation allowing use of a low-cost passive clamp circuit in boost mode. The converter includes a primary circuit, transformer and secondary circuit. The primary circuit takes the form of a “full bridge converter,” a “push-pull converter,” or an “L-type converter.”. The primary circuit may include a dissipator such as a snubber circuit or small buck converter. A secondary side of the...

  12. Potassium Chloride Versus Voltage Clamp Contractures in Ventricular Muscle

    Science.gov (United States)

    Morad, M.; Reeck, S.; Rao, M.

    1981-01-01

    In frog ventricle, developed tension was markedly larger in response to depolarization caused by a voltage clamp step than to depolarization induced by high concentrations of potassium chloride. Measurement of extracellular potassium activity at the surface and at the depth of muscle during the development of contractures showed that the diffusion of potassium is much slower than the spread of depolarization through the cross section of muscle. These two observations suggest that competition between the depolarizing and the negative inotropic effects of an increase in the extracellular potassium ion concentration may determine the time course and magnitude of contractile tension in heart muscle.

  13. Effect of Clamping Rigidity of the Armour on Ballistic Performance

    Directory of Open Access Journals (Sweden)

    S. N. Dikshit

    1992-04-01

    Full Text Available Influence of the manner in which the armour plates are held during their ballistic testing on the armour performance, has been evaluated. One armour plate was clamped rigidly to the test stand while a second plate of identical composition, hardness, and dimensions was hung loosely from the target holder. Both these plates were impacted with the same type of projectiles and over the same impact velocity range. The nature of ballistic damage evaluated indicates that the manner in which the armour is held during ballistic testing has a negligible influence on its performance at least when the mass of the plate is substantially higher than that of the projectile.

  14. Euglycemic clamp insulin sensitivity and longitudinal systolic blood pressure

    DEFF Research Database (Denmark)

    Petrie, John R; Malik, Muhammad Omar; Balkau, Beverley

    2013-01-01

    Insulin resistance may be an independent risk factor for the development of hypertension, but change in blood pressure (BP) over time has not been adequately studied in healthy individuals fully characterized for insulin sensitivity. In the Relationship between Insulin Sensitivity...... and Cardiovascular disease (RISC) study, we measured insulin sensitivity (M/I) using the euglycemic clamp technique in 1073 healthy European adults (587 women, 486 men) aged 30 to 60 years followed up 3 years later. Systolic BP (SBP) at baseline was higher in insulin-resistant women (ie, those in the low sex...

  15. Pulsewidth Modulation of Neutral-Point-Clamped Indirect Matrix Converter

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Poh Chiang, Loh; Gao, Feng

    2008-01-01

    discussed in the existing literature. Addressing the previously described issues, this paper focuses on the operational mode analysis of a three-level indirect matrix converter implemented using a neutral-point-clamped inversion stage and the design of a number of PWM and modulation ratio compensation...... schemes for controlling the converter with improved waveform quality. The performances and practicalities of the designed schemes are verified in simulation and experimentally using an implemented laboratory prototype with some representative results captured and presented in this paper....

  16. Hydraulic conductivity of compacted zeolites.

    Science.gov (United States)

    Oren, A Hakan; Ozdamar, Tuğçe

    2013-06-01

    Hydraulic conductivities of compacted zeolites were investigated as a function of compaction water content and zeolite particle size. Initially, the compaction characteristics of zeolites were determined. The compaction test results showed that maximum dry unit weight (γ(dmax)) of fine zeolite was greater than that of granular zeolites. The γ(dmax) of compacted zeolites was between 1.01 and 1.17 Mg m(-3) and optimum water content (w(opt)) was between 38% and 53%. Regardless of zeolite particle size, compacted zeolites had low γ(dmax) and high w(opt) when compared with compacted natural soils. Then, hydraulic conductivity tests were run on compacted zeolites. The hydraulic conductivity values were within the range of 2.0 × 10(-3) cm s(-1) to 1.1 × 10(-7) cm s(-1). Hydraulic conductivity of all compacted zeolites decreased almost 50 times as the water content increased. It is noteworthy that hydraulic conductivity of compacted zeolite was strongly dependent on the zeolite particle size. The hydraulic conductivity decreased almost three orders of magnitude up to 39% fine content; then, it remained almost unchanged beyond 39%. Only one report was found in the literature on the hydraulic conductivity of compacted zeolite, which is in agreement with the findings of this study.

  17. Hydraulic Actuators with Autonomous Hydraulic Supply for the Mainline Aircrafts

    Directory of Open Access Journals (Sweden)

    I. S. Shumilov

    2014-01-01

    Full Text Available Applied in the aircraft control systems, hydraulic servo actuators with autonomous hydraulic supply, so-called, hydraulic actuators of integrated configuration, i.e. combination of a source of hydraulic power and its load in the single unit, are aimed at increasing control system reliability both owing to elimination of the pipelines connecting the actuator to the hydraulic supply source, and owing to avoidance of influence of other loads failure on the actuator operability. Their purpose is also to raise control system survivability by eliminating the long pipeline communications and their replacing for the electro-conductive power supply system, thus reducing the vulnerability of systems. The main reason for a delayed application of the hydraulic actuators in the cutting-edge aircrafts was that such aircrafts require hydraulic actuators of considerably higher power with considerable heat releases, which caused an unacceptable overheat of the hydraulic actuators. Positive and negative sides of the hydraulic actuators, their alternative options of increased reliability and survivability, local hydraulic systems as an advanced alternative to independent hydraulic actuators are considered.Now to use hydraulic actuators in mainline aircrafts is inexpedient since there are the unfairly large number of the problems reducing, first and last, safety of flights, with no essential weight and operational advantages. Still works to create competitive hydraulic actuators ought to be continued.Application of local hydraulic systems (LHS will allow us to reduce length of pressure head and drain pipelines and mass of pipelines, as well as to raise their general fail-safety and survivability. Application of the LHS principle will allow us to use a majority of steering drive advantages. It is necessary to allocate especially the following:- ease of meeting requirements for the non-local spread of the engine weight;- essentially reducing length and weight of

  18. Hydraulic conductivity of organomodified soil

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, R.B.; Grant, J.M.; Voice, T.C.; Rakhshandehroo, G.; Xu, S.; Boyd, S.A. [Michigan State Univ., East Lansing, MI (United States)

    1995-11-01

    The effects of organomodification on soil hydraulic conductivity were investigated. Hydraulic conductivity and porosity of treated and untreated samples of a sandy loam were measured as a function of effective stress. Batch treatment with hexadecyltrimethyl ammonium (HDTMA) and dry packing produced organomodified samples that were 79% less conducive than untreated samples prior to loading. Treated samples lost less hydraulic conductivity as a result of loading than untreated samples so that treated samples had higher conductivity at high loads. Observed differences in conductivity are explained in terms of the role of the treated and untreated clay in controlling initial effective pore size and its change during consolidation.

  19. Low Energy Consumption Hydraulic Techniques

    Science.gov (United States)

    1988-08-30

    rod glands were made of 7075-T73 aluminum alloy with hard coat anodized and honed bores; the piston rods were chrome plated and precision ground. (2...the problem. For the sake of our test setup, the problem was temporarily solved by clamping a large metal sheath , which completely enclosed the tube

  20. Delayed clamping of the umbilical cord after delivery and implications for public cord blood banking.

    Science.gov (United States)

    Allan, David S; Scrivens, Nicholas; Lawless, Tiffany; Mostert, Karen; Oppenheimer, Lawrence; Walker, Mark; Petraszko, Tanya; Elmoazzen, Heidi

    2016-03-01

    Public banking of umbilical cord blood units (CBUs) containing higher numbers of cells ensures timely engraftment after transplantation for increasing numbers of patients. Delayed clamping of the umbilical cord after birth may benefit some infants by preventing iron deficiency. Implications of delayed cord clamping for public cord blood banking remains unclear. CBUs collected by Canadian Blood Services at one collection site between November 1, 2014, and March 17, 2015, were analyzed. The delay in cord clamping after birth was timed and classified as "no delay," 20 to 60 seconds, more than 60 seconds, or more than 120 seconds. Of 367 collections, 100 reported no delay in clamping while clamping was delayed by 20 to 60 seconds (n = 69), more than 60 seconds (n = 98), or more than 120 seconds (n = 100) in the remaining cases. The mean volume and total nucleated cells (TNCs) in units with no delay in clamping were significantly greater than mean volumes for all categories of delayed clamping (Tukey's test, p clamping was delayed (p = 5.5 × 10(-8) ). The difference was most marked for cords that were clamped more than 120 seconds after delivery (6.2% compared with 39%). Delayed cord clamping greatly diminishes the volume and TNC count of units collected for a public cord blood bank. Creating an inventory of CBUs with high TNC content may take more time than expected. © 2015 AABB.

  1. Delayed Umbilical Cord Clamping in the 21st Century: Indications for Practice.

    Science.gov (United States)

    Bayer, Kimberly

    2016-02-01

    Health care providers have debated the timing of umbilical cord clamping since the days of Aristotle. Delayed cord clamping was the mainstay of practice until about the 1950s when it was changed to immediate clamping on the basis of a series of blood volume studies combined with the introduction of active management of the third stage of labor. However, in recent years, several systematic reviews advise that delayed cord clamping should be used in all births for at least 30 to 60 seconds. The purpose of this article is to discuss the physiology of umbilical cord clamping, the potential benefits and adverse effects of delayed cord clamping, and how this affects the advanced practice nurse. A search of PubMed, Cochrane Reviews, and Clinical Key was used to find relevant research on the topic of umbilical cord clamping. Potential benefits of delayed cord clamping include decreased frequency of iron-deficiency anemia in the first year of life with improved neurodevelopmental outcomes in term infants, reduced need for blood transfusions, possible autologous transfusion of stem cells, and a decreased incidence of intraventricular hemorrhage. Apprehension exists regarding the feasibility of the practice as well as the potential hindrance of immediate resuscitation. There is a need to begin to look for populations for which delayed cord clamping can be implemented. Recommendations are inconsistent on the patient population and timing; therefore, further studies are needed to understand the multiple variables that affect timing of umbilical cord clamping.

  2. Randomised trial of cord clamping and initial stabilisation at very preterm birth.

    Science.gov (United States)

    Duley, Lelia; Dorling, Jon; Pushpa-Rajah, Angela; Oddie, Sam J; Yoxall, Charles William; Schoonakker, Bernard; Bradshaw, Lucy; Mitchell, Eleanor J; Fawke, Joe Anthony

    2017-09-18

    For very preterm births, to compare alternative policies for umbilical cord clamping and immediate neonatal care. Parallel group randomised (1:1) trial, using sealed opaque numbered envelopes. Eight UK tertiary maternity units. 261 women expected to have a live birth before 32 weeks, and their 276 babies. Cord clamping after at least 2 min and immediate neonatal care with cord intact, or clamping within 20 s and immediate neonatal care after clamping. Intraventricular haemorrhage (IVH), death before discharge. 132 women (137 babies) were allocated clamping ≥2 min and neonatal care cord intact, and 129 (139) clamping ≤20 s and neonatal care after clamping; six mother-infant dyads were excluded (2, 4) as birth was after 35(+6) weeks, one withdrew (death data only available) (0, 1). Median gestation was 28.9 weeks for those allocated clamping ≥2 min, and 29.2 for those allocated clamping ≤20 s. Median time to clamping was 120 and 11 s, respectively. 7 of 135 infants (5.2%) allocated clamping ≥2 min died and 15 of 135 (11.1%) allocated clamping ≤20 s; risk difference (RD) -5.9% (95% CI -12.4% to 0.6%). Of live births, 43 of 134 (32%) had IVH vs 47 of 132 (36%), respectively; RD -3.5% (-14.9% to 7.8%). There were no clear differences in other outcomes for infants or mothers. This is promising evidence that clamping after at least 2 min and immediate neonatal care with cord intact at very preterm birth may improve outcome; a large trial is urgently needed. ISRCTN 21456601. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  3. Patch-clamp detection of macromolecular translocation along nuclear pores

    Directory of Open Access Journals (Sweden)

    Bustamante J.O.

    1998-01-01

    Full Text Available The present paper reviews the application of patch-clamp principles to the detection and measurement of macromolecular translocation along the nuclear pores. We demonstrate that the tight-seal 'gigaseal' between the pipette tip and the nuclear membrane is possible in the presence of fully operational nuclear pores. We show that the ability to form a gigaseal in nucleus-attached configurations does not mean that only the activity of channels from the outer membrane of the nuclear envelope can be detected. Instead, we show that, in the presence of fully operational nuclear pores, it is likely that the large-conductance ion channel activity recorded derives from the nuclear pores. We conclude the technical section with the suggestion that the best way to demonstrate that the nuclear pores are responsible for ion channel activity is by showing with fluorescence microscopy the nuclear translocation of ions and small molecules and the exclusion of the same from the cisterna enclosed by the two membranes of the envelope. Since transcription factors and mRNAs, two major groups of nuclear macromolecules, use nuclear pores to enter and exit the nucleus and play essential roles in the control of gene activity and expression, this review should be useful to cell and molecular biologists interested in understanding how patch-clamp can be used to quantitate the translocation of such macromolecules into and out of the nucleus

  4. HYDRAULICS, ATHENS COUNTY, OHIO, USA

    Data.gov (United States)

    Federal Emergency Management Agency, Department of Homeland Security — Hydraulic data include spatial datasets and data tables necessary for documenting the hydrologic procedures for estimating flood discharges for a flood insurance...

  5. HYDRAULICS, JACKSON COUNTY, KENTUCKY, USA

    Data.gov (United States)

    Federal Emergency Management Agency, Department of Homeland Security — Hydraulic data include spatial datasets and data tables necessary for documenting the hydrologic procedures for estimating flood discharges for a flood insurance...

  6. HYDRAULICS, MADISON COUNTY, ALABAMA, USA

    Data.gov (United States)

    Federal Emergency Management Agency, Department of Homeland Security — This Hydraulic data was reviewed and approved by FEMA during the initial MT-2 processing. Recent developments in digital terrain and geospatial database management...

  7. HYDRAULICS, HAMPDEN COUNTY, MA, USA

    Data.gov (United States)

    Federal Emergency Management Agency, Department of Homeland Security — Hydraulic data in this submittal include spatial datasets and model outputs necessary for computation of the 1-percent flooding extent. The minimum requirement for...

  8. Hydraulic wind energy conversion system

    Energy Technology Data Exchange (ETDEWEB)

    1981-07-01

    The purpose of this research was to design, build and test a hydraulic wind energy system. This design used a three bladed turbine, which drove a hydraulic pump. The energy is transmitted from the pump through a long hose and into a hydraulic motor, where the energy is used. This wind system was built and tested during the winter of 1980-1981. The power train included a five meter, three bladed wind turbine, a 9.8:1 ratio gearbox, a 1.44 cubic inch displacement pump with a small supercharge gear pump attached. The hydraulic fluid was pumped through a 70', 3/4'' I-D-high pressure flexhose, then through a volume control valve and into a 1.44 cubic inch displacement motor. The fluid was returned through a 70', 1'' I-D-flexhose.

  9. 14 CFR 29.1435 - Hydraulic systems.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Hydraulic systems. 29.1435 Section 29.1435... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Miscellaneous Equipment § 29.1435 Hydraulic systems. (a) Design. Each hydraulic system must be designed as follows: (1) Each element of the hydraulic system...

  10. 14 CFR 23.1435 - Hydraulic systems.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Hydraulic systems. 23.1435 Section 23.1435... § 23.1435 Hydraulic systems. (a) Design. Each hydraulic system must be designed as follows: (1) Each hydraulic system and its elements must withstand, without yielding, the structural loads expected...

  11. 46 CFR 28.405 - Hydraulic equipment.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Hydraulic equipment. 28.405 Section 28.405 Shipping... Operate With More Than 16 Individuals on Board § 28.405 Hydraulic equipment. (a) Each hydraulic system... than four times the system maximum operating pressure. (c) Each hydraulic system must be equipped...

  12. Advanced Performance Hydraulic Wind Energy

    Science.gov (United States)

    Jones, Jack A.; Bruce, Allan; Lam, Adrienne S.

    2013-01-01

    The Jet Propulsion Laboratory, California Institute of Technology, has developed a novel advanced hydraulic wind energy design, which has up to 23% performance improvement over conventional wind turbine and conventional hydraulic wind energy systems with 5 m/sec winds. It also has significant cost advantages with levelized costs equal to coal (after carbon tax rebate). The design is equally applicable to tidal energy systems and has passed preliminary laboratory proof-of-performance tests, as funded by the Department of Energy.

  13. Optimal timing of umbilical cord clamping for term and preterm babies.

    Science.gov (United States)

    Duley, Lelia; Batey, Natalie

    2013-11-01

    Deferring cord clamping allows blood flow between baby and placenta to continue for a few moments. This often leads to increased neonatal blood volume at birth. It also allows for longer transition to the neonatal circulation. Optimal timing for clamping the cord remains uncertain. This paper discusses the physiology of placental transfusion and presents the evidence from systematic reviews of randomised trials comparing alternative strategies for cord clamping for both term and preterm births. For healthy term infants, deferring cord clamping increases iron stores in infancy. Therefore, a more liberal approach to deferring cord clamping appears to be warranted, provided screening and treatment for jaundice requiring phototherapy is available. For preterm births, although there are few data on the main clinical outcomes, the evidence is promising that deferred cord clamping may be beneficial. For both term and preterm infants there is little information about long term development. © 2013.

  14. Technologies and Innovations for Hydraulic Pumps

    OpenAIRE

    Ivantysynova, Monika

    2016-01-01

    Positive displacement machines working as hydraulic pumps or hydraulic motors have always been, are and will be an essential part of any hydraulic system. Current trends and future demands on energy efficient systems will not only drastically increase the number of positive displacement machines needed for modern efficient hydraulic circuits but will significantly change the performance requirements of pumps and motors. Throttleless system configurations will change the landscape of hydraulic...

  15. Application of Numerical Simulation for the Verification of Design of Clamping a Workpiece in Jaws

    Science.gov (United States)

    Oravcová, Jarmila; Riečičiarová, Eva

    2016-12-01

    This paper deals with the use of the numerical computer oriented method for the analysis and verification of the design of workpiece clamping. The inaccuracies of the positioning in clamping locating points were simulated using the FEM software ANSYS. The influence of inaccuracies in the positions of contact locating points on the displacements of the workpiece characteristic points and their position in clamped removable jaws was examined. The reaction forces in the contact locating points were also computed and analyzed.

  16. Delaying cord clamping until ventilation onset improves cardiovascular function at birth in preterm lambs.

    Science.gov (United States)

    Bhatt, Sasmira; Alison, Beth J; Wallace, Euan M; Crossley, Kelly J; Gill, Andrew W; Kluckow, Martin; te Pas, Arjan B; Morley, Colin J; Polglase, Graeme R; Hooper, Stuart B

    2013-04-15

    Delayed cord clamping improves circulatory stability in preterm infants at birth, but the underlying physiology is unclear. We investigated the effects of umbilical cord clamping, before and after ventilation onset, on cardiovascular function at birth. Prenatal surgery was performed on lambs (123 days) to implant catheters into the pulmonary and carotid arteries and probes to measure pulmonary (PBF), carotid (CaBF) and ductus arteriosus blood flows. Lambs were delivered at 126 ± 1 days and: (1) the umbilical cord was clamped at delivery and ventilation was delayed for about 2 min (Clamp 1st; n = 6), and (2) umbilical cord clamping was delayed for 3-4 min, until after ventilation was established (Vent 1st; n = 6). All lambs were subsequently ventilated for 30 min. In Clamp 1st lambs, cord clamping rapidly (within four heartbeats), but transiently, increased pulmonary and carotid arterial pressures (by ∼30%) and CaBF (from 30.2 ± 5.6 to 40.1 ± 4.6 ml min(-1) kg(-1)), which then decreased again within 30-60 s. Following ventilation onset, these parameters rapidly increased again. In Clamp 1st lambs, cord clamping reduced heart rate (by ∼40%) and right ventricular output (RVO; from 114.6 ± 14.4 to 38.8 ± 9.7 ml min(-1) kg(-1)), which were restored by ventilation. In Vent 1st lambs, cord clamping reduced RVO from 153.5 ± 3.8 to 119.2 ± 10.6 ml min(-1) kg(-1), did not affect heart rates and resulted in stable blood flows and pressures during transition. Delaying cord clamping for 3-4 min until after ventilation is established improves cardiovascular function by increasing pulmonary blood flow before the cord is clamped. As a result, cardiac output remains stable, leading to a smoother cardiovascular transition throughout the early newborn period.

  17. Delaying cord clamping until ventilation onset improves cardiovascular function at birth in preterm lambs

    Science.gov (United States)

    Bhatt, Sasmira; Alison, Beth J; Wallace, Euan M; Crossley, Kelly J; Gill, Andrew W; Kluckow, Martin; te Pas, Arjan B; Morley, Colin J; Polglase, Graeme R; Hooper, Stuart B

    2013-01-01

    Delayed cord clamping improves circulatory stability in preterm infants at birth, but the underlying physiology is unclear. We investigated the effects of umbilical cord clamping, before and after ventilation onset, on cardiovascular function at birth. Prenatal surgery was performed on lambs (123 days) to implant catheters into the pulmonary and carotid arteries and probes to measure pulmonary (PBF), carotid (CaBF) and ductus arteriosus blood flows. Lambs were delivered at 126 ± 1 days and: (1) the umbilical cord was clamped at delivery and ventilation was delayed for about 2 min (Clamp 1st; n = 6), and (2) umbilical cord clamping was delayed for 3–4 min, until after ventilation was established (Vent 1st; n = 6). All lambs were subsequently ventilated for 30 min. In Clamp 1st lambs, cord clamping rapidly (within four heartbeats), but transiently, increased pulmonary and carotid arterial pressures (by ∼30%) and CaBF (from 30.2 ± 5.6 to 40.1 ± 4.6 ml min−1 kg−1), which then decreased again within 30–60 s. Following ventilation onset, these parameters rapidly increased again. In Clamp 1st lambs, cord clamping reduced heart rate (by ∼40%) and right ventricular output (RVO; from 114.6 ± 14.4 to 38.8 ± 9.7 ml min−1 kg−1), which were restored by ventilation. In Vent 1st lambs, cord clamping reduced RVO from 153.5 ± 3.8 to 119.2 ± 10.6 ml min−1 kg−1, did not affect heart rates and resulted in stable blood flows and pressures during transition. Delaying cord clamping for 3–4 min until after ventilation is established improves cardiovascular function by increasing pulmonary blood flow before the cord is clamped. As a result, cardiac output remains stable, leading to a smoother cardiovascular transition throughout the early newborn period. PMID:23401615

  18. An Experimental Study of Measuring Oscillatory and Transient Pressures in Hydraulic Systems.

    Science.gov (United States)

    1978-12-01

    dynamic conditions. One of these computer programs that was of interest in this study was the Hydraulic Systems Frequency Response (HsFR). H- SFR program...reason for that failure is that the model for the hose was not accurate enough. The predicted amplitudes were much lower than measurec’ values except...the line. 6. P(%)- in line - Pclanp on x 100 ( 6 Pin line 7. Span - The distance between two clamps. The trans- ducers were located in the center of the

  19. Diuretic response to acute hypertension is blunted during angiotensin II clamp

    DEFF Research Database (Denmark)

    Leong, Patrick K K; Zhang, Yibin; Yang, Li E;

    2002-01-01

    ("ANG II clamp"). When blood pressure was acutely increased 50-60 mmHg by arterial constriction without ANG II clamp, urine output and endogenous lithium clearance increased 4.0- and 6.7-fold, respectively. With ANG II clamp, the effects of acute hypertension were reduced 50%: urine output...... and endogenous lithium clearance increased two- and threefold, respectively. We conclude that HOE-140, an inhibitor of the B(2) receptor, potentiates the sensitivity of arterial pressure to ANG II and that clamping systemic ANG II levels during acute hypertension blunts the magnitude of the pressure diuretic...

  20. Modeling of SVM Diode Clamping Three-Level Inverter Connected to Grid

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Zhu, Jieqiong

    2011-01-01

    PLECS is used to model the diode clamping three-level inverter connected to grid and good results are obtained. First the output voltage SVM is described for diode clamping three-level inverter with loads connected to Y. Then the output voltage SVM of diode clamping three-level inverter is simply...... is very powerful tool to real power circuits and it is very easy to simulate them. They have also verified that SVM control strategy is feasible to control the diode clamping three-level inverter....

  1. Electrically integrated SU-8 clamped graphene drum resonators for strain engineering

    Science.gov (United States)

    Lee, Sunwoo; Chen, Changyao; Deshpande, Vikram V.; Lee, Gwan-Hyoung; Lee, Ilkyu; Lekas, Michael; Gondarenko, Alexander; Yu, Young-Jun; Shepard, Kenneth; Kim, Philip; Hone, James

    2013-04-01

    Graphene mechanical resonators are the ultimate two-dimensional nanoelectromechanical systems (NEMS) with applications in sensing and signal processing. While initial devices have shown promising results, an ideal graphene NEMS resonator should be strain engineered, clamped at the edge without trapping gas underneath, and electrically integratable. In this Letter, we demonstrate fabrication and direct electrical measurement of circular SU-8 polymer-clamped chemical vapor deposition graphene drum resonators. The clamping increases device yield and responsivity, while providing a cleaner resonance spectrum from eliminated edge modes. Furthermore, the clamping induces a large strain in the resonator, increasing its resonant frequency.

  2. COMPARISON OF EARLY AND DELAYED UMBILICAL CORD CLAMPING IN THE THIRD STAGE OF LABOUR

    Directory of Open Access Journals (Sweden)

    Tamara Serdinšek

    2015-09-01

    Full Text Available Background: Umbilical cord clamping in the third stage of labour is still controversial. Early cord clamping is defined as clamping at 10, 15, 30 or 60 seconds after delivery and delayed as clamping after 60 seconds or at 2-5 minutes after delivery, when the cord stops pulsating or when the placenta is visible within the birth canal. Early clamping is one of the three components of active management of the third stage of labour, which has been used widely in modern obstetrics during the last century. However, in some northern European countries, various parts of the USA and Canada and in developing countries physiological management is preferred.Conclusions: After publication of several trials describing advantages of delayed clamping, this has recently been progressively replacing early clamping. The most important advantages of delayed cord clamping are higher haemoglobin and ferritin levels, higher iron stores, lower incidence of iron deficiency anaemia, better cardiopulmonary adaptation, lower rate of respiratory distress syndrome, and longer duration of early breastfeeding in term neonates, while there is no increase in the incidence of postpartum haemorrhage. Delayed clamping seems to bring some advantages for preterm neonates as well. However, caution is still advised because of the potential adverse effects, especially polycythaemia with hyperviscosity, hyperbilirubinaemia and respiratory distress.

  3. Beliefs and practices of obstetric care providers regarding umbilical cord clamping.

    Science.gov (United States)

    Hill, Allyson L; Fontenot, Holly B

    2014-01-01

    The optimal timing for umbilical cord clamping after birth has yet to be established, and controversy exists. There is evidence of potentially significant health benefits of delayed cord clamping for both full-term and preterm newborns, but this practice has not been widely adopted. This column takes a second look at two recent studies in which researchers examined the beliefs and practices of obstetric care providers regarding umbilical cord clamping in North America. Nurses who are aware of the latest science and who understand both existing practice patterns as well as practice barriers to delayed clamping can be leaders in and advocates for change. © 2014 AWHONN.

  4. Cryogenic Clamp-on Ultrasonic Flowmeters using Single Crystal Piezoelectric Transducers Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Clamp-on ultrasound cryogenic flowmeters using single crystal piezoelectric transducers are proposed to enable reliable, accurate cryogenic instrumentation needs in...

  5. Mechanism of ATP-driven PCNA clamp loading by S. cerevisiae RFC.

    Science.gov (United States)

    Chen, Siying; Levin, Mikhail K; Sakato, Miho; Zhou, Yayan; Hingorani, Manju M

    2009-05-08

    Circular clamps tether polymerases to DNA, serving as essential processivity factors in genome replication, and function in other critical cellular processes as well. Clamp loaders catalyze clamp assembly onto DNA, and the question of how these proteins construct a topological link between a clamp and DNA, especially the mechanism by which ATP is utilized for the task, remains open. Here we describe pre-steady-state analysis of ATP hydrolysis, proliferating cell nuclear antigen (PCNA) clamp opening, and DNA binding by Saccharomyces cerevisiae replication factor C (RFC), and present the first kinetic model of a eukaryotic clamp-loading reaction validated by global data analysis. ATP binding to multiple RFC subunits initiates a slow conformational change in the clamp loader, enabling it to bind and open PCNA and to bind DNA as well. PCNA opening locks RFC into an active state, and the resulting RFC.ATP.PCNA((open)) intermediate is ready for the entry of DNA into the clamp. DNA binding commits RFC to ATP hydrolysis, which is followed by PCNA closure and PCNA.DNA release. This model enables quantitative understanding of the multistep mechanism of a eukaryotic clamp loader and furthermore facilitates comparative analysis of loaders from diverse organisms.

  6. Electrothermally actuated tunable clamped-guided resonant microbeams

    KAUST Repository

    Alcheikh, Nouha

    2017-06-11

    We present simulation and experimental investigation demonstrating active alteration of the resonant and frequency response behavior of resonators by controlling the electrothermal actuation method on their anchors. In-plane clamped-guided arch and straight microbeams resonators are designed and fabricated with V-shaped electrothermal actuators on their anchors. These anchors not only offer various electrothermal actuation options, but also serve as various mechanical stiffness elements that affect the operating resonance frequency of the structures. We have shown that for an arch, the first mode resonance frequency can be increased up to 50% of its initial value. For a straight beam, we have shown that before buckling, the resonance frequency decreases to very low values and after buckling, it increases up to twice of its initial value. These results can be promising for the realization of different wide–range tunable microresonator. The experimental results have been compared to multi-physics finite-element simulations showing good agreement among them.

  7. Trans-Z-source Neutral Point Clamped inverter

    DEFF Research Database (Denmark)

    Mo, W.; Loh, P. C.; Li, D.;

    2012-01-01

    Transformer based Z-source (trans-Z-source) inverters are recently proposed by extending the traditional Z-source inverter with higher buck-boost capability as well as reducing the passive components at the same time. Multi-Level Z-source inverters are single-stage topological solutions used...... modulation scheme, the three-level trans-Z-source inverter can function with minimum of six device commutations per half carrier cycle (same as the traditional buck NPC inverter), while maintaining to produce the designed volt-sec average and inductive voltage boosting at ac output terminals. The designed...... for buck-boost energy conversion with all the favourable advantages of multi-level switching retained. This paper presents three-level trans-Z-source Neutral Point Clamped (NPC) inverter topology, which achieves both the advantages of trans-Z-source and three-level NPC inverter configuration. With proper...

  8. The timing of umbilical cord clamping at birth: physiological considerations.

    Science.gov (United States)

    Hooper, Stuart B; Binder-Heschl, Corinna; Polglase, Graeme R; Gill, Andrew W; Kluckow, Martin; Wallace, Euan M; Blank, Douglas; Te Pas, Arjan B

    2016-01-01

    While it is now recognized that umbilical cord clamping (UCC) at birth is not necessarily an innocuous act, there is still much confusion concerning the potential benefits and harms of this common procedure. It is most commonly assumed that delaying UCC will automatically result in a time-dependent net placental-to-infant blood transfusion, irrespective of the infant's physiological state. Whether or not this occurs, will likely depend on the infant's physiological state and not on the amount of time that has elapsed between birth and umbilical cord clamping (UCC). However, we believe that this is an overly simplistic view of what can occur during delayed UCC and ignores the benefits associated with maintaining the infant's venous return and cardiac output during transition. Recent experimental evidence and observations in humans have provided compelling evidence to demonstrate that time is not a major factor influencing placental-to-infant blood transfusion after birth. Indeed, there are many factors that influence blood flow in the umbilical vessels after birth, which depending on the dominating factors could potentially result in infant-to-placental blood transfusion. The most dominant factors that influence umbilical artery and venous blood flows after birth are lung aeration, spontaneous inspirations, crying and uterine contractions. It is still not entirely clear whether gravity differentially alters umbilical artery and venous flows, although the available data suggests that its influence, if present, is minimal. While there is much support for delaying UCC at birth, much of the debate has focused on a time-based approach, which we believe is misguided. While a time-based approach is much easier and convenient for the caregiver, ignoring the infant's physiology during delayed UCC can potentially be counter-productive for the infant.

  9. Current umbilical cord clamping practices and attitudes of obstetricians and midwives toward delayed cord clamping in Saudi Arabia.

    Science.gov (United States)

    Ibrahim, Nadia O; Sukkarieh, Hatouf H; Bustami, Rami T; Alshammari, Elaf A; Alasmari, Lama Y; Al-Kadri, Hanan M

    2017-01-01

    In Saudi Arabia, as in many countries, there is usually no clear definition of the timing of umbilical cord clamping (UCC) in the policies and procedures used by hospitals. The World Health Organization (WHO) recommends delayed cord clamping (DCC) ( > 1 minute after birth) as it can significantly improve hemodynamics and long-term neurodevelopment. To investigate current practices of healthcare professionals on the timing of UCC in Saudi Arabia. Cross-sectional survey. Five tertiary hospitals in Riyadh, Saudi Arabia, during May to October 2016. Obstetricians and midwives completed a widely-used questionnaire on UCC practices. Current UCC practices and attitudes of obstetricians and midwives toward DCC. Eighty-two obstetricians and 75 midwives completed the questionnaire for a response rate of 80%. The majority of respondents were aged 30 years or older (81%) and 84% were females. Most respondents were non-Saudi (66%) and had an educational level of bachelor's degree or higher (72%). Only 42% of respondents reported the existence of UCC guidelines in their practice; 38% reported the existence of a set time for UCC when the neonate was term and healthy, and only 32% had a set time for UCC in preterm neonates. While lower levels of agreement were reported among obstetricians and midwives on the benefits of DCC for babies requiring positive pressure ventilation, the majority of respondents (69-71%) thought that DCC was generally good for both term and preterm babies and that its benefits extend beyond the neonatal period. While the majority of obstetricians and midwives that participated in this study had a positive perception toward DCC, this did not translate to their daily practice as most of these professionals reported a lack of existing UCC guidelines in their institutions. Further studies are warranted to confirm these findings. Participant selection by convenience sampling.

  10. Complex Fluids and Hydraulic Fracturing.

    Science.gov (United States)

    Barbati, Alexander C; Desroches, Jean; Robisson, Agathe; McKinley, Gareth H

    2016-06-07

    Nearly 70 years old, hydraulic fracturing is a core technique for stimulating hydrocarbon production in a majority of oil and gas reservoirs. Complex fluids are implemented in nearly every step of the fracturing process, most significantly to generate and sustain fractures and transport and distribute proppant particles during and following fluid injection. An extremely wide range of complex fluids are used: naturally occurring polysaccharide and synthetic polymer solutions, aqueous physical and chemical gels, organic gels, micellar surfactant solutions, emulsions, and foams. These fluids are loaded over a wide range of concentrations with particles of varying sizes and aspect ratios and are subjected to extreme mechanical and environmental conditions. We describe the settings of hydraulic fracturing (framed by geology), fracturing mechanics and physics, and the critical role that non-Newtonian fluid dynamics and complex fluids play in the hydraulic fracturing process.

  11. Hydraulic properties of ladle slags

    Directory of Open Access Journals (Sweden)

    J. Vlček

    2016-07-01

    Full Text Available The article presents results of examining of hydraulic properties of ladle slags formed during production of steel. The studied ladle slags were subjected to different cooling mode from the molten state. Based on the ability of the slag react with the water was assessed their hydraulic activity. The hydraulic properties are caused by the presence of minerals dicalcium silicate, tricalcium aluminate, mayenite, brownmillerite and dicalcium ferite. The emergence of required hydrating phases in the ladle slags is conditioned by a sufficient CaO content and their cooling rate. The contact the slag with water during processing and their ageing has a negative effect. The experiment has shown that the phase transformation of the mineral dicalcium silicate which occurs during cooling of the ladle slags cause their volume instability.

  12. Hydraulic resistance of biofilms

    KAUST Repository

    Dreszer, C.

    2013-02-01

    Biofilms may interfere with membrane performance in at least three ways: (i) increase of the transmembrane pressure drop, (ii) increase of feed channel (feed-concentrate) pressure drop, and (iii) increase of transmembrane passage. Given the relevance of biofouling, it is surprising how few data exist about the hydraulic resistance of biofilms that may affect the transmembrane pressure drop and membrane passage. In this study, biofilms were generated in a lab scale cross flow microfiltration system at two fluxes (20 and 100Lm-2h-1) and constant cross flow (0.1ms-1). As a nutrient source, acetate was added (1.0mgL-1 acetate C) besides a control without nutrient supply. A microfiltration (MF) membrane was chosen because the MF membrane resistance is very low compared to the expected biofilm resistance and, thus, biofilm resistance can be determined accurately. Transmembrane pressure drop was monitored. As biofilm parameters, thickness, total cell number, TOC, and extracellular polymeric substances (EPS) were determined, it was demonstrated that no internal membrane fouling occurred and that the fouling layer actually consisted of a grown biofilm and was not a filter cake of accumulated bacterial cells. At 20Lm-2h-1 flux with a nutrient dosage of 1mgL-1 acetate C, the resistance after 4 days reached a value of 6×1012m-1. At 100Lm-2h-1 flux under the same conditions, the resistance was 5×1013m-1. No correlation of biofilm resistance to biofilm thickness was found; Biofilms with similar thickness could have different resistance depending on the applied flux. The cell number in biofilms was between 4×107 and 5×108 cellscm-2. At this number, bacterial cells make up less than a half percent of the overall biofilm volume and therefore did not hamper the water flow through the biofilm significantly. A flux of 100Lm-2h-1 with nutrient supply caused higher cell numbers, more biomass, and higher biofilm resistance than a flux of 20Lm-2h-1. However, the biofilm thickness

  13. Controls of Hydraulic Wind Turbine

    Directory of Open Access Journals (Sweden)

    Zhang Yin

    2016-01-01

    Full Text Available In this paper a hydraulic wind turbine generator system was proposed based on analysis the current wind turbines technologies. The construction and principles were introduced. The mathematical model was verified using MATLAB and AMsim. A displacement closed loop of swash plate of motor and a speed closed loop of generator were setup, a PID control is introduced to maintain a constant speed and fixed frequency at wind turbine generator. Simulation and experiment demonstrated that the system can connect grid to generate electric and enhance reliability. The control system demonstrates a high performance speed regulation and effectiveness. The results are great significant to design a new type hydraulic wind turbine system.

  14. Structural insight into β-Clamp and its interaction with DNA Ligase in Helicobacter pylori.

    Science.gov (United States)

    Pandey, Preeti; Tarique, Khaja Faisal; Mazumder, Mohit; Rehman, Syed Arif Abdul; Kumari, Nilima; Gourinath, Samudrala

    2016-08-08

    Helicobacter pylori, a gram-negative and microaerophilic bacterium, is the major cause of chronic gastritis, gastric ulcers and gastric cancer. Owing to its central role, DNA replication machinery has emerged as a prime target for the development of antimicrobial drugs. Here, we report 2Å structure of β-clamp from H. pylori (Hpβ-clamp), which is one of the critical components of DNA polymerase III. Despite of similarity in the overall fold of eubacterial β-clamp structures, some distinct features in DNA interacting loops exists that have not been reported previously. The in silico prediction identified the potential binders of β-clamp such as alpha subunit of DNA pol III and DNA ligase with identification of β-clamp binding regions in them and validated by SPR studies. Hpβ-clamp interacts with DNA ligase in micromolar binding affinity. Moreover, we have successfully determined the co-crystal structure of β-clamp with peptide from DNA ligase (not reported earlier in prokaryotes) revealing the region from ligase that interacts with β-clamp.

  15. The transducer domain is important for clamp operation in human DNA topoisomerase IIalpha

    DEFF Research Database (Denmark)

    Oestergaard, Vibe H; Bjergbaek, Lotte; Skouboe, Camilla

    2003-01-01

    the clamp to the enzyme core. Although structurally conserved, it is unclear whether the transducer domain is involved in clamp mechanism. We have purified and characterized a human topoisomerase II alpha enzyme with a two-amino acid insertion at position 408 in the transducer domain. The enzyme retains...

  16. Angiotensin II clamp prevents the second step in renal apical NHE3 internalization during acute hypertension

    DEFF Research Database (Denmark)

    Leong, Patrick K K; Yang, Li E; McDonough, Alicia A

    2002-01-01

    . Plasma ANG II concentration of anesthesized Sprague-Dawley rats was clamped by simultaneous infusion of the ANG I-converting enzyme inhibitor captopril (12 microg/min) and ANG II (20 ng. kg(-1). min(-1)). Blood pressure was increased 50 mmHg for 20 min by arterial constriction +/- ANG II clamp or by sham...

  17. Implementing dynamic clamp with synaptic and artificial conductances in mouse retinal ganglion cells.

    Science.gov (United States)

    Huang, Jin Y; Stiefel, Klaus M; Protti, Dario A

    2013-05-16

    Ganglion cells are the output neurons of the retina and their activity reflects the integration of multiple synaptic inputs arising from specific neural circuits. Patch clamp techniques, in voltage clamp and current clamp configurations, are commonly used to study the physiological properties of neurons and to characterize their synaptic inputs. Although the application of these techniques is highly informative, they pose various limitations. For example, it is difficult to quantify how the precise interactions of excitatory and inhibitory inputs determine response output. To address this issue, we used a modified current clamp technique, dynamic clamp, also called conductance clamp (1, 2, 3) and examined the impact of excitatory and inhibitory synaptic inputs on neuronal excitability. This technique requires the injection of current into the cell and is dependent on the real-time feedback of its membrane potential at that time. The injected current is calculated from predetermined excitatory and inhibitory synaptic conductances, their reversal potentials and the cell's instantaneous membrane potential. Details on the experimental procedures, patch clamping cells to achieve a whole-cell configuration and employment of the dynamic clamp technique are illustrated in this video article. Here, we show the responses of mouse retinal ganglion cells to various conductance waveforms obtained from physiological experiments in control conditions or in the presence of drugs. Furthermore, we show the use of artificial excitatory and inhibitory conductances generated using alpha functions to investigate the responses of the cells.

  18. Integrating hydraulic equivalent sections into a hydraulic geometry study

    Science.gov (United States)

    Jia, Yanhong; Yi, Yujun; Li, Zhiwei; Wang, Zhaoyin; Zheng, Xiangmin

    2017-09-01

    Hydraulic geometry (HG) is an important geomorphic concept that has played an indispensable role in hydrological analyses, physical studies of streams, ecosystem and aquatic habitat studies, and sedimentology research. More than 60 years after Leopold and Maddock (1953) first introduced the concept of HG, researchers have still not uncovered the physical principles underlying HG behavior. One impediment is the complexity of the natural river cross section. The current study presents a new way to simplify the cross section, namely, the hydraulic equivalent section, which is generalized from the cross section in the ;gradually varied flow of an alluvial river; (GVFAR) and features hydrodynamic properties and bed-building laws similar to those of the GVFAR. Energy balance was used to derive the stage Z-discharge Q relationship in the GVFAR. The GVFAR in the Songhua River and the Yangtze River were selected as examples. The data, including measured discharge, river width, water stage, water depth, wet area, and cross section, were collected from the hydrological yearbooks of typical hydrological stations on the Songhua River and the Yangtze River from 1955 to 1987. The relationships between stage Z-discharge Q and cross-sectional area A-stage Z at various stations were analyzed, and ;at-a-station hydraulic geometry; (AHG) relationships were obtained in power-law forms. Based on derived results and observational data analysis, the Z-Q and Z-A relationships of AHG were similar to rectangular weir flows, thus the cross section of the GVFAR was generalized as a compound rectangular, hydraulic equivalent cross section. As to bed-building characteristics, the bankfull discharge method and the stage-discharge-relation method were used to calculate the dominant variables of the alluvial river. This hydraulic equivalent section has the same Z-Q relation, Z-A relation, dominant discharge, dominant river width, and dominant water depth as the cross section in the GVFAR. With the

  19. Effect of delayed cord clamping on very preterm infants.

    Science.gov (United States)

    Chiruvolu, Arpitha; Tolia, Veeral N; Qin, Huanying; Stone, Genna Leal; Rich, Diana; Conant, Rhoda J; Inzer, Robert W

    2015-11-01

    Despite significant proposed benefits, delayed umbilical cord clamping (DCC) is not practiced widely in preterm infants largely because of the question of feasibility of the procedure and uncertainty regarding the magnitude of the reported benefits, especially intraventricular hemorrhage (IVH) vs the adverse consequences of delaying the neonatal resuscitation. The objective of this study was to determine whether implementation of the protocol-driven DCC process in our institution would reduce the incidence of IVH in very preterm infants without adverse consequences. We implemented a quality improvement process for DCC the started in August 2013 in infants born at ≤32 weeks' gestational age. Eligible infants were left attached to the placenta for 45 seconds after birth. Neonatal process and outcome data were collected until discharge. We compared infants who received DCC who were born between August 2013 and August 2014 with a historic cohort of infants who were born between August 2012 and August 2013, who were eligible to receive DCC, but whose cord was clamped immediately after birth, because they were born before the protocol implementation. DCC was performed on all the 60 eligible infants; 88 infants were identified as historic control subjects. Gestational age, birthweight, and other demographic variables were similar between both groups. There were no differences in Apgar scores or admission temperature, but significantly fewer infants in the DCC cohort were intubated in delivery room, had respiratory distress syndrome, or received red blood cell transfusions in the first week of life compared with the historic cohort. A significant reduction was noted in the incidence of IVH in the DCC cohort compared with the historic control group (18.3% vs 35.2%). After adjustment for gestational age, an association was found between the incidence of IVH and DCC with IVH was significantly lower in the DCC cohort compared with the historic cohort; an odds ratio of 0

  20. On the mechanism of loading the PCNA sliding clamp by RFC.

    Science.gov (United States)

    Dionne, Isabelle; Brown, Nicola J; Woodgate, Roger; Bell, Stephen D

    2008-04-01

    Sliding clamps play central roles in a broad range of DNA replication and repair processes. The clamps form circular molecules that must be opened and resealed around DNA by the clamp loader complex to fulfil their function. While most eukaryotes and many archea possess a homo-trimeric PCNA, the PCNA of Sulfolobus solfataricus is a heterotrimer. Here, we exploit the asymmetry of S. solfataricus PCNA to create a series of circularly permuted PCNA subunit fusions, thereby covalently closing defined interfaces within the heterotrimer. Using these concatamers, we investigate the requirements for loading the clamp onto DNA and reveal that a single defined interface within the heterotrimer is opened during the loading process. Subunit-specific interactions between S. solfataricus RFC clamp loader and PCNA permit us to superimpose our data upon the structure of yeast RFC-PCNA complex, thereby presenting a general model for PCNA loading by RFC in archaea and eukaryotes.

  1. A reduction clamp for an aiming component in associated acetabular fractures

    Directory of Open Access Journals (Sweden)

    Zhang-Fu Wang

    2015-01-01

    Full Text Available Background: The treatment of acetabular fractures is complex and requires specialized equipment. However, all currently available instruments have some disadvantages. A new reduction clamp that can firmly enable reduction and not hinder subsequent fixation procedures for some special fracture types is needed. Materials and Methods: In this study, we introduce a new acetabular clamp and its preliminary clinical application in three T-shaped acetabular fractures. Results: This new clamp can successfully pull the posterior column back to the anterior column and firmly maintain the reduction. This clamp′s aiming plate can facilitate the insertion of long lag screws. The clamp is also easy to assemble and use. Conclusion: This reduction clamp is a useful instrument that can facilitate open reduction and internal fixation of acetabular fractures.

  2. The deformation of an elastic rod with a clamp sliding along a smooth and curved profile

    CERN Document Server

    Misseroni, D; Zaccaria, D; Bigoni, D

    2015-01-01

    The design of compliant mechanisms is crucial in several technologies and relies on the availability of solutions for nonlinear structural problems. One of these solutions is given and experimentally validated in the present article for a compliant mechanism moving along a smooth curved profile. In particular, a deformable elastic rod is held by two clamps, one at each end. The first clamp is constrained to slide without friction along a curved profile, while the second clamp moves in a straight line transmitting its motion through the elastic rod to the first clamp. For this system it is shown that the clamp sliding on the profile imposes nontrivial boundary conditions (derived via a variational and an asymptotic approach), which strongly influence buckling and nonlinear structural behaviour. Investigation of this behaviour shows that a compliant mechanism can be designed, which gives an almost neutral response in compression. This behavior could easily be exploited to make a force limiting device. Finally a...

  3. Note: High-efficiency energy harvester using double-clamped piezoelectric beams

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Yingmei; Wu, Xuan; Parmar, Mitesh; Lee, Dong-weon, E-mail: mems@jnu.ac.kr [MEMS and Nanotechnology Laboratory, School of Mechanical Systems Engineering, Chonnam National University, Gwangju (Korea, Republic of)

    2014-02-15

    In this study, an improvement in energy conversion efficiency has been reported, which is realized by using a double-clamped piezoelectric beam, based on uniaxial stretching strain. The buckling mechanism is applied to maximize axial stress in the double-clamped beam. The voltage generated by using the double-clamped piezoelectric beam is higher than that generated by using other conventional structures, such as bending cantilevers coated/sandwiched with piezoelectric film, which is proven both theoretically and experimentally. The power generation efficiency is enhanced by further optimizing the double-clamped structure. The optimized high-efficiency energy harvester utilizing double-clamped piezoelectric beams generates a peak output power of 80 μW, under an acceleration of 0.1g.

  4. Note: high-efficiency energy harvester using double-clamped piezoelectric beams.

    Science.gov (United States)

    Zheng, Yingmei; Wu, Xuan; Parmar, Mitesh; Lee, Dong-weon

    2014-02-01

    In this study, an improvement in energy conversion efficiency has been reported, which is realized by using a double-clamped piezoelectric beam, based on uniaxial stretching strain. The buckling mechanism is applied to maximize axial stress in the double-clamped beam. The voltage generated by using the double-clamped piezoelectric beam is higher than that generated by using other conventional structures, such as bending cantilevers coated/sandwiched with piezoelectric film, which is proven both theoretically and experimentally. The power generation efficiency is enhanced by further optimizing the double-clamped structure. The optimized high-efficiency energy harvester utilizing double-clamped piezoelectric beams generates a peak output power of 80 μW, under an acceleration of 0.1g.

  5. Effects of Delayed Umbilical Cord Clamping vs Early Clamping on Anemia in Infants at 8 and 12 Months: A Randomized Clinical Trial.

    Science.gov (United States)

    Kc, Ashish; Rana, Nisha; Målqvist, Mats; Jarawka Ranneberg, Linda; Subedi, Kalpana; Andersson, Ola

    2017-03-01

    Delayed umbilical cord clamping has been shown to improve iron stores in infants to 6 months of age. However, delayed cord clamping has not been shown to prevent iron deficiency or anemia after 6 months of age. To investigate the effects of delayed umbilical cord clamping, compared with early clamping, on hemoglobin and ferritin levels at 8 and 12 months of age in infants at high risk for iron deficiency anemia. This randomized clinical trial included 540 late preterm and term infants born vaginally at a tertiary hospital in Kathmandu, Nepal, from October 2 to November 21, 2014. Follow-up included blood levels of hemoglobin and ferritin at 8 and 12 months of age. Follow-up was completed on December 11, 2015. Analysis was based on intention to treat. Infants were randomized to delayed umbilical cord clamping (≥180 seconds after delivery) or early clamping (≤60 seconds after delivery). Main outcomes included hemoglobin and anemia levels at 8 months of age with the power estimate based on the prevalence of anemia. Secondary outcomes included hemoglobin and anemia levels at 12 months of age and ferritin level, iron deficiency, and iron deficiency anemia at 8 and 12 months of age. In this study of 540 infants (281 boys [52.0%] and 259 girls [48.0%]; mean [SD] gestational age, 39.2 [1.1] weeks), 270 each were randomized to the delayed and early clamping groups. At 8 months of age, 212 infants (78.5%) from the delayed group and 188 (69.6%) from the early clamping group returned for blood sampling. After multiple imputation analysis, infants undergoing delayed clamping had higher levels of hemoglobin (10.4 vs 10.2 g/dL; difference, 0.2 g/dL; 95% CI, 0.1 to 0.4 g/dL). Delayed cord clamping also reduced the prevalence of anemia (hemoglobin level clamping group in 60 (22.2%) vs 103 (38.1%) patients (relative risk, 0.58; 95% CI, 0.44-0.77; NNT, 6; 95% CI, 4-13). At 12 months, delayed cord clamping still resulted in a hemoglobin level of 0.3 (95% CI, 0.04-0.5) g/dL higher

  6. CRITICALITY CURVES FOR PLUTONIUM HYDRAULIC FLUID MIXTURES

    Energy Technology Data Exchange (ETDEWEB)

    WITTEKIND WD

    2007-10-03

    This Calculation Note performs and documents MCNP criticality calculations for plutonium (100% {sup 239}Pu) hydraulic fluid mixtures. Spherical geometry was used for these generalized criticality safety calculations and three geometries of neutron reflection are: {sm_bullet}bare, {sm_bullet}1 inch of hydraulic fluid, or {sm_bullet}12 inches of hydraulic fluid. This document shows the critical volume and critical mass for various concentrations of plutonium in hydraulic fluid. Between 1 and 2 gallons of hydraulic fluid were discovered in the bottom of HA-23S. This HA-23S hydraulic fluid was reported by engineering to be Fyrquel 220. The hydraulic fluid in GLovebox HA-23S is Fyrquel 220 which contains phosphorus. Critical spherical geometry in air is calculated with 0 in., 1 in., or 12 inches hydraulic fluid reflection.

  7. DCS Hydraulics Submittal, Butler County, Alabama, USA

    Data.gov (United States)

    Federal Emergency Management Agency, Department of Homeland Security — Hydraulics data includes spatial datasets and data tables necessary for documenting the hydraulic procedures for computing flood elevations for a flood insurance...

  8. DCS Hydraulics Submittal, Bullock County, Alabama, USA

    Data.gov (United States)

    Federal Emergency Management Agency, Department of Homeland Security — Hydraulics data includes spatial datasets and data tables necessary for documenting the hydraulic procedures for computing flood elevations for a flood insurance...

  9. DCS Hydraulics Submittal, Covington County, Alabama, USA

    Data.gov (United States)

    Federal Emergency Management Agency, Department of Homeland Security — Hydraulics data includes spatial datasets and data tables necessary for documenting the hydraulic procedures for computing flood elevations for a flood insurance...

  10. High Pressure Hydraulic Distribution System

    Science.gov (United States)

    1991-05-20

    to 500 0 F. 5 cycles. 5000 F room temperature to 50001F; 45 ______________ Icycles The tesis planned for the distribution system demonstrator were...American Society for Testing and Materials ASTM D412 - Tension Testing of Vulcanized Rubber ASTM D571 - Testing Automotive Hydraulic Brake Hose Society of

  11. Hydraulic fracturing system and method

    Energy Technology Data Exchange (ETDEWEB)

    Ciezobka, Jordan; Salehi, Iraj

    2017-02-28

    A hydraulic fracturing system and method for enhancing effective permeability of earth formations to increase hydrocarbon production, enhance operation efficiency by reducing fluid entry friction due to tortuosity and perforation, and to open perforations that are either unopened or not effective using traditional techniques, by varying a pump rate and/or a flow rate to a wellbore.

  12. Hydraulic jumps in a channel

    DEFF Research Database (Denmark)

    Bonn, D.; Andersen, Anders Peter; Bohr, Tomas

    2009-01-01

    We present a study of hydraulic jumps with flow predominantly in one direction, created either by confining the flow to a narrow channel with parallel walls or by providing an inflow in the form of a narrow sheet. In the channel flow, we find a linear height profile upstream of the jump as expected...

  13. Hydraulic Fracture Containment in Sand

    NARCIS (Netherlands)

    Dong, Y.

    2010-01-01

    The mechanism of hydraulic fracturing in soft, high permeability material is considered fundamentally different from that in hard, low permeability rock, where a tensile fracture is created and conventional linear elastic fracture mechanics (LEFM) applies. The fracturing and associated modeling work

  14. Design of hydraulic recuperation unit

    Directory of Open Access Journals (Sweden)

    Jandourek Pavel

    2016-01-01

    Full Text Available This article deals with design and measurement of hydraulic recuperation unit. Recuperation unit consist of radial turbine and axial pump, which are coupled on the same shaft. Speed of shaft with impellers are 6000 1/min. For economic reasons, is design of recuperation unit performed using commercially manufactured propellers.

  15. Tree Hydraulics: How Sap Rises

    Science.gov (United States)

    Denny, Mark

    2012-01-01

    Trees transport water from roots to crown--a height that can exceed 100 m. The physics of tree hydraulics can be conveyed with simple fluid dynamics based upon the Hagen-Poiseuille equation and Murray's law. Here the conduit structure is modelled as conical pipes and as branching pipes. The force required to lift sap is generated mostly by…

  16. Tree Hydraulics: How Sap Rises

    Science.gov (United States)

    Denny, Mark

    2012-01-01

    Trees transport water from roots to crown--a height that can exceed 100 m. The physics of tree hydraulics can be conveyed with simple fluid dynamics based upon the Hagen-Poiseuille equation and Murray's law. Here the conduit structure is modelled as conical pipes and as branching pipes. The force required to lift sap is generated mostly by…

  17. Simultaneous patch-clamping and calcium imaging in developing dendrites.

    Science.gov (United States)

    Kleindienst, Thomas; Lohmann, Christian

    2014-03-01

    Calcium imaging has been used extensively to explore the role of action potential (AP) firing in the development of neuronal structure and synaptic function because increases in intracellular calcium ([Ca(2+)]i) reliably and, within a certain range, linearly reflect neuronal spiking activity. Patterns of APs in individual cells can be deduced from calcium recordings, which have typically been performed at the level of cell bodies. However, neurons are particularly susceptible to phototoxicity when they are illuminated at the soma. Furthermore, for some imaging experiments (e.g., those that address the interactions between dendrites and axons during synapse formation), the cell body of a given neuron may simply not be in the field of view. In these situations, it would be helpful to determine the spiking patterns of a neuron from the calcium activity in its subcellular compartments such as stretches of dendrites or axons. Here, we describe an approach for determining the relationship between AP firing and dendritic calcium transients by simultaneously imaging calcium transients in small dendritic stretches of hippocampal pyramidal neurons in slice cultures from neonatal rats and recording spiking activity with whole-cell patch-clamp recordings in these neurons. These experiments allow us to correlate the electrophysiological spiking pattern with the accompanying changes in the calcium concentration in individual dendritic segments.

  18. Non-Hookean statistical mechanics of clamped graphene ribbons

    Science.gov (United States)

    Bowick, Mark J.; Košmrlj, Andrej; Nelson, David R.; Sknepnek, Rastko

    2017-03-01

    Thermally fluctuating sheets and ribbons provide an intriguing forum in which to investigate strong violations of Hooke's Law: Large distance elastic parameters are in fact not constant but instead depend on the macroscopic dimensions. Inspired by recent experiments on free-standing graphene cantilevers, we combine the statistical mechanics of thin elastic plates and large-scale numerical simulations to investigate the thermal renormalization of the bending rigidity of graphene ribbons clamped at one end. For ribbons of dimensions W ×L (with L ≥W ), the macroscopic bending rigidity κR determined from cantilever deformations is independent of the width when W ℓth , however, this thermally renormalized bending rigidity begins to systematically increase, in agreement with the scaling theory, although in our simulations we were not quite able to reach the system sizes necessary to determine the fully developed power law dependence on W . When the ribbon length L >ℓp , where ℓp is the W -dependent thermally renormalized ribbon persistence length, we observe a scaling collapse and the beginnings of large scale random walk behavior.

  19. Umbilical Cord Milking Versus Delayed Cord Clamping in Preterm Infants.

    Science.gov (United States)

    Katheria, Anup C; Truong, Giang; Cousins, Larry; Oshiro, Bryan; Finer, Neil N

    2015-07-01

    Delayed cord clamping (DCC) is recommended for premature infants to improve blood volume. Most preterm infants are born by cesarean delivery (CD), and placental transfusion may be less effective than in vaginal delivery (VD). We sought to determine whether infants umbilical cord milking (UCM) have higher measures of systemic blood flow than infants who undergo DCC. This was a 2-center trial. Infants delivered by CD were randomly assigned to undergo UCM or DCC. Infants delivered by VD were also randomly assigned separately. UCM (4 strippings) or DCC (45-60 seconds) were performed. Continuous hemodynamic measurements and echocardiography were done at site 1. A total of 197 infants were enrolled (mean gestational age 28 ± 2 weeks). Of the 154 infants delivered by CD, 75 were assigned to UCM and 79 to DCC. Of the infants delivered by CD, neonates randomly assigned to UCM had higher superior vena cava flow and right ventricular output in the first 12 hours of life. Neonates undergoing UCM also had higher hemoglobin, delivery room temperature, blood pressure over the first 15 hours, and urine output in the first 24 hours of life. There were no differences for the 43 infants delivered by VD. This is the first randomized controlled trial demonstrating higher systemic blood flow with UCM in preterm neonates compared with DCC. UCM may be a more efficient technique to improve blood volume in premature infants delivered by CD. Copyright © 2015 by the American Academy of Pediatrics.

  20. A new linear type hydraulic motor

    Science.gov (United States)

    Jiang, Dong; Zhang, Tong; Li, Wenhua; Chen, Xinyang

    2017-08-01

    This paper proposes the design of liner type hydraulic motor on the base of inner curved radial piston hydraulic motor. The hydraulic cylinders of the new type motor are in the straight line which will improve the utilization of the axial space and different out power can be supplied by changes the number of cylinders. In this paper, the structure and working principle of the liner type hydraulic motor is introduced.

  1. Hydraulic characterization of " Furcraea andina

    Science.gov (United States)

    Rivera-Velasquez, M. F.; Fallico, C.; Molinari, A.; Santillan, P.; Salazar, M.

    2012-04-01

    The present level of pollution, increasingly involving groundwaters, constitutes a serious risk for environment and human health. Therefore the remediation of saturated and unsaturated soils, removing pollutant materials through innovative and economic bio-remediation techniques is more frequently required. Recent studies on natural fiber development have shown the effectiveness of these fibers for removal of some heavy metals, due to the lignin content in the natural fibers which plays an important role in the adsorption of metal cations (Lee et al., 2004; Troisi et al., 2008; C. Fallico, 2010). In the context of remediation techniques for unsaturated and/or saturated zone, an experimental approach for the hydraulic characterization of the "Furcraea andina" (i.e., Cabuya Blanca) fiber was carried out. This fiber is native to Andean regions and grows easily in wild or cultivated form in the valleys and hillsides of Colombia, Ecuador, and Peru. Fibers of "Furcraea andina" were characterized by experimental tests to determine their hydraulic conductivity or permeability and porosity in order to use this medium for bioremediation of contaminated aquifer exploiting the physical, chemical and microbial capacity of natural fiber in heavy metal adsorption. To evaluate empirically the hydraulic conductivity, laboratory tests were carried out at constant head specifically on the fibers manually extracted. For these tests we used a flow cell (used as permeameter), containing the "Furcraea andina" fibers to be characterized, suitably connected by a tygon pipe to a Marriott's bottle, which had a plastic tube that allow the adjustment of the hydraulic head for different tests to a constant value. By this experiment it was also possible to identify relationships that enable the estimation of permeability as a function of density, i.e. of the compaction degree of the fibers. Our study was carried out for three values of hydraulic head (H), namely 10, 18, and 25 cm and for each

  2. 14 CFR 25.1435 - Hydraulic systems.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Hydraulic systems. 25.1435 Section 25.1435... STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Miscellaneous Equipment § 25.1435 Hydraulic systems. (a) Element design. Each element of the hydraulic system must be designed to: (1) Withstand the proof...

  3. 14 CFR 27.1435 - Hydraulic systems.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Hydraulic systems. 27.1435 Section 27.1435... STANDARDS: NORMAL CATEGORY ROTORCRAFT Equipment Safety Equipment § 27.1435 Hydraulic systems. (a) Design. Each hydraulic system and its elements must withstand, without yielding, any structural loads...

  4. Committee Opinion No. 684 Summary: Delayed Umbilical Cord Clamping After Birth.

    Science.gov (United States)

    2017-01-01

    Delayed umbilical cord clamping appears to be beneficial for term and preterm infants. In term infants, delayed umbilical cord clamping increases hemoglobin levels at birth and improves iron stores in the first several months of life, which may have a favorable effect on developmental outcomes. There is a small increase in jaundice that requires phototherapy in this group of infants. Consequently, health care providers adopting delayed umbilical cord clamping in term infants should ensure that mechanisms are in place to monitor for and treat neonatal jaundice. In preterm infants, delayed umbilical cord clamping is associated with significant neonatal benefits, including improved transitional circulation, better establishment of red blood cell volume, decreased need for blood transfusion, and lower incidence of necrotizing enterocolitis and intraventricular hemorrhage. Delayed umbilical cord clamping was not associated with an increased risk of postpartum hemorrhage or increased blood loss at delivery, nor was it associated with a difference in postpartum hemoglobin levels or the need for blood transfusion. Given the benefits to most newborns and concordant with other professional organizations, the American College of Obstetricians and Gynecologists now recommends a delay in umbilical cord clamping in vigorous term and preterm infants for at least 30-60 seconds after birth. The ability to provide delayed umbilical cord clamping may vary among institutions and settings; decisions in those circumstances are best made by the team caring for the mother-infant dyad.

  5. Committee Opinion No.543: Timing of umbilical cord clamping after birth.

    Science.gov (United States)

    2012-12-01

    The optimal timing for clamping the umbilical cord after birth has been a subject of controversy and debate. Although many randomized controlled trials in term and preterm infants have evaluated the benefits of delayed umbilical cord clamping versus immediate umbilical cord clamping, the ideal timing for cord clamping has yet to be established. Several systematic reviews have suggested that clamping the umbilical cord in all births should be delayed for at least 30-60 seconds, with the infant maintained at or below the level of the placenta because of the associated neonatal benefits, including increased blood volume, reduced need for blood transfusion, decreased incidence of intracranial hemorrhage in preterm infants, and lower frequency of iron deficiency anemia in term infants. Evidence exists to support delayed umbilical cord clamping in preterm infants, when feasible. The single most important clinical benefit for preterm infants is the possibility for a nearly 50% reduction in intraventricular hemorrhage. However, currently, evidence is insufficient to confirm or refute the potential for benefits from delayed umbilical cord clamping in term infants, especially in settings with rich resources.

  6. Blood gas values in clamped and unclamped umbilical cord at birth.

    Science.gov (United States)

    Di Tommaso, Mariarosaria; Seravalli, Viola; Martini, Irene; La Torre, Pasquale; Dani, Carlo

    2014-09-01

    To determine the reliability of the cord blood gas analysis on the unclamped cord compared to the standard technique of sampling on double clamped cord. Prospective observational study conducted on 46 singleton neonates vaginally delivered at term. Matched pairs of umbilical artery and vein blood samples were collected from unclamped cord within 90s after birth and from the same cord after clamping, with the clamping occurring immediately after the first blood collection. A blood gas analysis was performed on each collected sample. Arterial and venous blood samples were analyzed for pH, PO2, pCO2, SaO2, hemoglobin concentration (ctHb) and base excess (BE). The values were compared between the two groups (clamped vs unclamped) using a Wilcoxon test. No significant difference was found in pH, PO2, pCO2, SaO2 and ctHb values on arterial blood between unclamped and clamped cord. The only significant difference was related to BE (pblood, the values of pH, PO2, pCO2 were comparable between unclamped and clamped cord, while the values of SaO2, ctHb and BE were significantly different (pblood gas parameters and in the main venous blood gas parameters between unclamped and clamped cord. Sampling of cord blood for gas analysis may be performed on the unclamped cord right after birth without reducing the accuracy of the analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Immunologic and infectious consequences of immediate versus delayed umbilical cord clamping in premature infants: a prospective, randomized, controlled study.

    Science.gov (United States)

    Kugelman, Amir; Borenstein-Levin, Liron; Kessel, Aharon; Riskin, Arieh; Toubi, Elias; Bader, David

    2009-01-01

    To evaluate the immunologic and infectious consequences of delayed versus immediate cord clamping in premature infants (cord clamping (ICC) at 5-10 s and 30 infants to delayed cord clamping (DCC), at 30-45 s (14 and 15 infants in each group were cord clamping did not affect the immunologic or the infectious status of infants born at <35 weeks during the neonatal period.

  8. Thermal Hydraulic Performance of Tight Lattice Bundle

    Science.gov (United States)

    Yamamoto, Yasushi; Akiba, Miyuki; Morooka, Shinichi; Shirakawa, Kenetsu; Abe, Nobuaki

    Recently, the reduced moderation spectrum BWR has been studied. The fast neutron spectrum is obtained through triangular tight lattice fuel. However, there are few thermal hydraulic test data and thermal hydraulic correlation applicable to critical power prediction in such a tight lattice bundle. This study aims to enhance the database of the thermal hydraulic performance of the tight lattice bundle whose rod gap is about 1mm. Therefore, thermal hydraulic performance measurement tests of tight lattice bundles for the critical power, the pressure drop and the counter current flow limiting were performed. Moreover, the correlations to evaluate the thermal-hydraulic performance of the tight lattice bundle were developed.

  9. Design of hydraulic output Stirling engine

    Science.gov (United States)

    Toscano, W. M.; Harvey, A. C.; Lee, K.

    1983-01-01

    A hydraulic output system for the RE-1000 free piston stirling engine (FPSE) was designed. The hydraulic output system can be readily integrated with the existing hot section of RE-1000 FPSE. The system has two simply supported diaphragms which separate the engine gas from the hydraulic fluid, a dynamic balance mechanism, and a novel, null center band hydraulic pump. The diaphragms are designed to endure more than 10 billion cycles, and to withstand the differential pressure load as high as 14 MPa. The projected thermodynamic performance of the hydraulic output version of RE-1000 FPSE is 1.87 kW at 29/7 percent brake efficiency.

  10. Analysis of the role of PCNA-DNA contacts during clamp loading

    Directory of Open Access Journals (Sweden)

    Goedken Eric R

    2010-01-01

    Full Text Available Abstract Background Sliding clamps, such as Proliferating Cell Nuclear Antigen (PCNA in eukaryotes, are ring-shaped protein complexes that encircle DNA and enable highly processive DNA replication by serving as docking sites for DNA polymerases. In an ATP-dependent reaction, clamp loader complexes, such as the Replication Factor-C (RFC complex in eukaryotes, open the clamp and load it around primer-template DNA. Results We built a model of RFC bound to PCNA and DNA based on existing crystal structures of clamp loaders. This model suggests that DNA would enter the clamp at an angle during clamp loading, thereby interacting with positively charged residues in the center of PCNA. We show that simultaneous mutation of Lys 20, Lys 77, Arg 80, and Arg 149, which interact with DNA in the RFC-PCNA-DNA model, compromises the ability of yeast PCNA to stimulate the DNA-dependent ATPase activity of RFC when the DNA is long enough to extend through the clamp. Fluorescence anisotropy binding experiments show that the inability of the mutant clamp proteins to stimulate RFC ATPase activity is likely caused by reduction in the affinity of the RFC-PCNA complex for DNA. We obtained several crystal forms of yeast PCNA-DNA complexes, measuring X-ray diffraction data to 3.0 Å resolution for one such complex. The resulting electron density maps show that DNA is bound in a tilted orientation relative to PCNA, but makes different contacts than those implicated in clamp loading. Because of apparent partial disorder in the DNA, we restricted refinement of the DNA to a rigid body model. This result contrasts with previous analysis of a bacterial clamp bound to DNA, where the DNA was well resolved. Conclusion Mutational analysis of PCNA suggests that positively charged residues in the center of the clamp create a binding surface that makes contact with DNA. Disruption of this positive surface, which had not previously been implicated in clamp loading function, reduces RFC

  11. A Central Swivel Point in the RFC Clamp Loader Controls PCNA Opening and Loading on DNA

    OpenAIRE

    Sakato, Miho; O’Donnell, Mike; Hingorani, Manju M.

    2011-01-01

    Replication Factor C (RFC) is a 5-subunit complex that loads PCNA clamps onto primer-template DNA (ptDNA) during replication. RFC subunits belong to the AAA+ superfamily, and their ATPase activity drives interactions between the clamp loader, clamp, and ptDNA, leading to topologically linked PCNA•ptDNA. We report the kinetics of transient events in S. cerevisiae RFC catalyzed PCNA loading, including ATP-induced RFC activation, PCNA opening, ptDNA binding, ATP hydrolysis, PCNA closing and PCNA...

  12. Characterization of potassium channel modulators with QPatch automated patch-clamp technology: system characteristics and performance

    DEFF Research Database (Denmark)

    Kutchinsky, Jonatan; Friis, Søren; Asmild, Margit

    2003-01-01

    Planar silicon chips with 1-2-microm etched holes (average resistance: 2.04 +/- 0.02 MOmega in physiological buffer, n = 274) have been developed for patch-clamp recordings of whole-cell currents from cells in suspension. An automated 16-channel parallel screening system, QPatch 16, has been...... developed using this technology. A single-channel prototype of the QPatch system was used for validation of the patch-clamp chip technology. We present here data on the quality of patch-clamp recordings and from actual drug screening studies of human potassium channels expressed in cultured cell lines...

  13. Modelling the clamping force distribution among chips in press-pack IGBTs using the finite element method

    DEFF Research Database (Denmark)

    Hasmasan, Adrian Augustin; Busca, Christian; Teodorescu, Remus

    2012-01-01

    In this paper, a FEM (finite element method) based mechanical model for PP (press-pack) IGBTs (insulated gate bipolar transistors) is presented, which can be used to calculate the clamping force distribution among chips under various clamping conditions. The clamping force is an important paramet...

  14. Hydraulic fracture during epithelial stretching

    Science.gov (United States)

    Casares, Laura; Vincent, Romaric; Zalvidea, Dobryna; Campillo, Noelia; Navajas, Daniel; Arroyo, Marino; Trepat, Xavier

    2015-03-01

    The origin of fracture in epithelial cell sheets subject to stretch is commonly attributed to excess tension in the cells’ cytoskeleton, in the plasma membrane, or in cell-cell contacts. Here, we demonstrate that for a variety of synthetic and physiological hydrogel substrates the formation of epithelial cracks is caused by tissue stretching independently of epithelial tension. We show that the origin of the cracks is hydraulic; they result from a transient pressure build-up in the substrate during stretch and compression manoeuvres. After pressure equilibration, cracks heal readily through actomyosin-dependent mechanisms. The observed phenomenology is captured by the theory of poroelasticity, which predicts the size and healing dynamics of epithelial cracks as a function of the stiffness, geometry and composition of the hydrogel substrate. Our findings demonstrate that epithelial integrity is determined in a tension-independent manner by the coupling between tissue stretching and matrix hydraulics.

  15. Bio-based Hydraulic Fluids

    Science.gov (United States)

    2008-04-17

    currently formulated with vegetable oils (i.e., rapeseed , sun flower, corn, soybean, canola, coconut, etc.) and synthetic ester, such as polyol ester...2008 Vegetable Oil • Excellent lubrication • Nontoxic • Biodegradable • Derived from renewable resources such as rapeseed , sunflower, corn...Mineral Oil 100 SAE 15W-40 G Rapeseed 32 Commercial HF H Polyol ester 22 MIL-PRF-32073 Grade 2 I Canola - Cooking Oil *Hydraulic fluid 3717 April

  16. Fire Resistant Aircraft Hydraulic System.

    Science.gov (United States)

    1982-07-01

    and compounds based on new experimental elastomers as well as most commercially available elastomers were screened in seeking seals that were both...for hydraulic component testing. All of the available E6.5 stock was purchased for the screening tests. However, DuPont stated that other homologs of...with the lubricity and anti-wear additive olyvan A (molybdenum oxysulphide dithiocarbamate ) added in the quantity of less than one percent by weight

  17. Electrosurgical bipolar vessel sealing versus conventional clamping and suturing for total abdominal hysterectomy: a randomized trial.

    NARCIS (Netherlands)

    Lakeman, M.; Kruitwagen, R.F.P.M.; Vos, M.C.; Roovers, J.P.

    2008-01-01

    STUDY OBJECTIVE: To compare the effects of bipolar vessel sealing versus conventional clamping and suturing in women undergoing total abdominal hysterectomy. DESIGN: A randomized controlled trial was performed. Patients were randomized to vessel sealing or conventional surgery. Postoperative pain wa

  18. Common voltage eliminating of SVM diode clamping three-level inverter connected to grid

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Zhu, Jieqiong

    2011-01-01

    A novel method of common voltage eliminating is put forward for SVM diode clamping three-level inverter connected to grid by calculation of common voltage of its various switching states. PLECS is used to model this three-level inverter connected to grid and good results are obtained. First...... analysis of common mode voltage for switching states of diode clamping 3-level inverter is given in detail. Second the common mode voltage eliminating control strategy of SVM is described for diode clamping three-level inverter. Third, PLECS is briefly introduced. Fourth, the modeling of diode clamping...... three-level inverter is presented with PLECS. Finally, a series of simulations are carried out. The simulation results tell us PLECS is a very powerful tool to real power circuits modeling. They have also verified that proposed common mode voltage eliminating control strategy of SVM is feasible...

  19. Renal perfusion with venous blood extends the permissible suprarenal clamp time in abdominal aortic surgery

    National Research Council Canada - National Science Library

    Pichlmaier, Maximilian; Hoy, Ludwig; Wilhelmi, Mathias; Khaladj, Nawid; Haverich, Axel; Teebken, Omke E

    2008-01-01

    ... suprarenal clamping for aortic reconstructive surgery. Renal perfusion was achieved using a roller pump supplied with venous blood from a central venous catheter under medium-level heparinization to feed two perfusion balloon catheters...

  20. Suppression of Spiral Waves by Voltage Clamp Techniques in a Conductance-Based Cardiac Tissue Model

    Institute of Scientific and Technical Information of China (English)

    YU Lian-Chun; MA Jun; ZHANG Guo-Yong; CHEN Yong

    2008-01-01

    A new control method is proposed to control the spatio-temporal dynamics in excitable media, which is described by the Morris-Lecar cells model. It is confirmed that successful suppression of spiral waves can be obtained by spatially clamping the membrane voltage of the excitable cells. The low voltage clamping induces breakup of spiral waves and the fragments are soon absorbed by low voltage obstacles, whereas the high voltage clamping generates travel waves that annihilate spiral waves through collision with them. However, each method has its shortcomings. Furthermore, a two-step method that combines both low and high voltage clamp techniques is then presented as a possible way of out this predicament.

  1. Implementation of a fast 16-Bit dynamic clamp using LabVIEW-RT.

    Science.gov (United States)

    Kullmann, Paul H M; Wheeler, Diek W; Beacom, Joshua; Horn, John P

    2004-01-01

    The dynamic-clamp method provides a powerful electrophysiological tool for creating virtual ionic conductances in living cells and studying their influence on membrane potential. Here we describe G-clamp, a new way to implement a dynamic clamp using the real-time version of the Lab-VIEW programming environment together with a Windows host, an embedded microprocessor that runs a real-time operating system and a multifunction data-acquisition board. The software includes descriptions of a fast voltage-dependent sodium conductance, delayed rectifier, M-type and A-type potassium conductances, and a leak conductance. The system can also read synaptic conductance waveforms from preassembled data files. These virtual conductances can be reliably implemented at speeds LabVIEW should make it relatively easy for others to adapt G-clamp for new experimental applications.

  2. Hydraulic Redistribution: A Modeling Perspective

    Science.gov (United States)

    Daly, E.; Verma, P.; Loheide, S. P., III

    2014-12-01

    Roots play a key role in the soil water balance. They extract and transport water for transpiration, which usually represents the most important soil water loss in vegetated areas, and can redistribute soil water, thereby increasing transpiration rates and enhancing root nutrient uptake. We present here a two-dimensional model capable of describing two key aspects of root water uptake: root water compensation and hydraulic redistribution. Root water compensation is the ability of root systems to respond to the reduction of water uptake from areas of the soil with low soil water potential by increasing the water uptake from the roots in soil parts with higher water potential. Hydraulic redistribution is a passive transfer of water through the root system from areas of the soil with greater water potential to areas with lower water potential. Both mechanisms are driven by gradients of water potential in the soil and the roots. The inclusion of root water compensation and hydraulic redistribution in models can be achieved by describing root water uptake as a function of the difference in water potential between soil and root xylem. We use a model comprising the Richards equation for the water flow in variably saturated soils and the Darcy's equation for the water flow in the xylem. The two equations are coupled via a sink term, which is assumed to be proportional to the difference between soil and xylem water potentials. The model is applied in two case studies to describe vertical and horizontal hydraulic redistribution and the interaction between vegetation with different root depths. In the case of horizontal redistribution, the model is used to reproduce the fluxes of water across the root system of a tree subjected to uneven irrigation. This example can be extended to situations when only part of the root system has access to water, such as vegetation near creeks, trees at the edge of forests, and street trees in urban areas. The second case is inspired by recent

  3. Modeling CICR in rat ventricular myocytes: voltage clamp studies

    Directory of Open Access Journals (Sweden)

    Palade Philip T

    2010-11-01

    Full Text Available Abstract Background The past thirty-five years have seen an intense search for the molecular mechanisms underlying calcium-induced calcium-release (CICR in cardiac myocytes, with voltage clamp (VC studies being the leading tool employed. Several VC protocols including lowering of extracellular calcium to affect Ca2+ loading of the sarcoplasmic reticulum (SR, and administration of blockers caffeine and thapsigargin have been utilized to probe the phenomena surrounding SR Ca2+ release. Here, we develop a deterministic mathematical model of a rat ventricular myocyte under VC conditions, to better understand mechanisms underlying the response of an isolated cell to calcium perturbation. Motivation for the study was to pinpoint key control variables influencing CICR and examine the role of CICR in the context of a physiological control system regulating cytosolic Ca2+ concentration ([Ca2+]myo. Methods The cell model consists of an electrical-equivalent model for the cell membrane and a fluid-compartment model describing the flux of ionic species between the extracellular and several intracellular compartments (cell cytosol, SR and the dyadic coupling unit (DCU, in which resides the mechanistic basis of CICR. The DCU is described as a controller-actuator mechanism, internally stabilized by negative feedback control of the unit's two diametrically-opposed Ca2+ channels (trigger-channel and release-channel. It releases Ca2+ flux into the cyto-plasm and is in turn enclosed within a negative feedback loop involving the SERCA pump, regulating[Ca2+]myo. Results Our model reproduces measured VC data published by several laboratories, and generates graded Ca2+ release at high Ca2+ gain in a homeostatically-controlled environment where [Ca2+]myo is precisely regulated. We elucidate the importance of the DCU elements in this process, particularly the role of the ryanodine receptor in controlling SR Ca2+ release, its activation by trigger Ca2+, and its

  4. Patch Clamp: A Powerful Technique for Studying the Mechanism of Acupuncture

    Directory of Open Access Journals (Sweden)

    D. Zhang

    2012-01-01

    Full Text Available Cellular and molecular events can be investigated using electrophysiological techniques. In particular, the patch-clamp method provides detailed information. In addition, the patch-clamp technique has become a powerful method for investigating the mechanisms underlying the effects of acupuncture. In this paper, recent researches on how acupuncture might modulate electrophysiological responses in the central nervous system (CNS and affect peripheral structures are reviewed.

  5. Delayed umbilical cord clamping after childbirth: potential benefits to baby's health

    Directory of Open Access Journals (Sweden)

    Uwins C

    2014-11-01

    Full Text Available Christina Uwins,1 David JR Hutchon2 1Department of Obstetrics and Gynaecology, Croydon University Hospital, Croydon, 2Department of Obstetrics, Darlington Memorial Hospital, Darlington, UKAbstract: Early cord clamping was initially introduced as part of the package of care known as “active management of the third stage”, which was implemented to reduce postpartum hemorrhage. It has now been shown to provide no benefit to the mother and to result in harm to the neonate. The clinical trial evidence relating to delayed cord clamping compared to immediate cord clamping is presented and the physiological rationale for delayed cord clamping is discussed in this paper. Most organizations (eg World Health Organization (WHO, Royal College of Obstetricians and Gynaecologists (RCOG, Resuscitation Council (UK,The International Federation of Gynecology and Obstetrics (FIGO, International Confederation of Midwives, International Liaison Committee on Resuscitation (ILCOR and the European Resuscitation Council now advise a delay of 1–3 minutes before clamping the cord in term and preterm infants, and clinicians need to be aware of this change. Healthy neonates benefit from a more physiological and gentle transition from placental to pulmonary respiration, and we explain why this benefit should be provided to all neonates until there is any evidence to the contrary. The harm of early cord clamping is not limited to anemia and iron deficiency, and evidence for a wide range of possible harms of early cord clamping is presented. The need for resuscitation is one of the most common concerns, and ways of overcoming these concerns are described.Keywords: transition, cord clamping, hypovolemia, intraventricular hemorrhage

  6. Effect of non-ideal clamping shape on the resonance frequencies of silicon nanocantilevers

    Energy Technology Data Exchange (ETDEWEB)

    Guillon, Samuel; Saya, Daisuke; Mazenq, Laurent; Nicu, Liviu [CNRS, LAAS, 7 Avenue du Colonel Roche, F-31077 Toulouse Cedex 4 (France); Perisanu, Sorin; Vincent, Pascal [LPMCN, Universite Claude Bernard Lyon 1 et CNRS, 43 boulevard du 11 novembre 1918, 69622 Villeurbanne Cedex (France); Lazarus, Arnaud; Thomas, Olivier, E-mail: sguillon@laas.fr [Structural Mechanics and Coupled Systems Laboratory, Conservatoire National des Arts et Metiers, 2 rue Conte, 75003 Paris (France)

    2011-06-17

    In this paper, we investigate the effects of non-ideal clamping shapes on the dynamic behavior of silicon nanocantilevers. We fabricated silicon nanocantilevers using silicon on insulator (SOI) wafers by employing stepper ultraviolet (UV) lithography, which permits a resolution of under 100 nm. The nanocantilevers were driven by electrostatic force inside a scanning electron microscope (SEM). Both lateral and out-of-plane resonance frequencies were visually detected with the SEM. Next, we discuss overhanging of the cantilever support and curvature at the clamping point in the silicon nanocantilevers, which generally arises in the fabrication process. We found that the fundamental out-of-plane frequency of a realistically clamped cantilever is always lower than that for a perfectly clamped cantilever, and depends on the cantilever width and the geometry of the clamping point structure. Using simulation with the finite-elements method, we demonstrate that this discrepancy is attributed to the particular geometry of the clamping point (non-zero joining curvatures and a flexible overhanging) that is obtained in the fabrication process. The influence of the material orthotropy is also investigated and is shown to be negligible.

  7. A novel monolithic piezoelectric actuated flexure-mechanism based wire clamp for microelectronic device packaging

    Science.gov (United States)

    Liang, Cunman; Wang, Fujun; Tian, Yanling; Zhao, Xingyu; Zhang, Hongjie; Cui, Liangyu; Zhang, Dawei; Ferreira, Placid

    2015-04-01

    A novel monolithic piezoelectric actuated wire clamp is presented in this paper to achieve fast, accurate, and robust microelectronic device packaging. The wire clamp has compact, flexure-based mechanical structure and light weight. To obtain large and robust jaw displacements and ensure parallel jaw grasping, a two-stage amplification composed of a homothetic bridge type mechanism and a parallelogram leverage mechanism was designed. Pseudo-rigid-body model and Lagrange approaches were employed to conduct the kinematic, static, and dynamic modeling of the wire clamp and optimization design was carried out. The displacement amplification ratio, maximum allowable stress, and natural frequency were calculated. Finite element analysis (FEA) was conducted to evaluate the characteristics of the wire clamp and wire electro discharge machining technique was utilized to fabricate the monolithic structure. Experimental tests were carried out to investigate the performance and the experimental results match well with the theoretical calculation and FEA. The amplification ratio of the clamp is 20.96 and the working mode frequency is 895 Hz. Step response test shows that the wire clamp has fast response and high accuracy and the motion resolution is 0.2 μm. High speed precision grasping operations of gold and copper wires were realized using the wire clamper.

  8. A High Step-Down Interleaved Buck Converter with Active-Clamp Circuits for Wind Turbines

    Directory of Open Access Journals (Sweden)

    Chih-Lung Shen

    2012-12-01

    Full Text Available In this paper, a high step-down interleaved buck coupled-inductor converter (IBCC with active-clamp circuits for wind energy conversion has been studied. In high step-down voltage applications, an IBCC can extend duty ratio and reduce voltage stresses on active switches. In order to reduce switching losses of active switches to improve conversion efficiency, a IBCC with soft-switching techniques is usually required. Compared with passive-clamp circuits, the IBCC with active-clamp circuits have lower switching losses and minimum ringing voltage of the active switches. Thus, the proposed IBCC with active-clamp circuits for wind energy conversion can significantly increase conversion efficiency. Finally, a 240 W prototype of the proposed IBCC with active-clamp circuits was built and implemented. Experimental results have shown that efficiency can reach as high as 91%. The proposed IBCC with active-clamp circuits is presented in high step-down voltage applications to verify the performance and the feasibility for energy conversion of wind turbines.

  9. The effect of early and late umbilical cord clamping on neonatal hematocrit.

    Science.gov (United States)

    Jahazi, A; Kordi, M; Mirbehbahani, N B; Mazloom, S R

    2008-08-01

    To compare the effect of early and late cord clamping (LCC) on neonatal hematocrit at 2 and 18 h of life. In this double-blind randomized trial, 64 healthy full-term vaginally born neonates were randomly allocated to either early (30 s) or late (3 min) umbilical cord clamping. During the interval between delivery and cord clamping, the attendant held the neonate supine at the level of the introitus. Neonatal venous hematocrit was measured at 2 and 18 h of life. Neonatal hematocrit at 2 h of life (61+/-4.9 vs 61.6+/-4.5%) and 18 h of life (56.9+/-4.1 vs 56.2+/-3.9%) was not significantly different between the two groups. This was also true for neonatal polycythemia (20 vs 23.5%). In the LCC group, placental residual blood volume (PRBV) was 39.5% lower and estimated neonatal blood volume (ENBV) was 7.1% higher than that in the early cord clamping (ECC) group (Pcord clamping does not lead to a significant difference in the hematocrit level of the neonate or neonatal polycythemia, but is associated with a significant increase in ENBV and a significant decrease in PRBV. Further trials should examine the effect of delaying cord clamping for a longer period of time or changing the position that the neonate is held in to determine whether these variations result in more clinically significant results.

  10. Late umbilical cord clamping, neonatal hematocrit and Apgar scores: a randomized controlled trial.

    Science.gov (United States)

    Salari, Z; Rezapour, M; Khalili, N

    2014-01-01

    Based on current evidence, there is a little agreement on the best timing for after birth umbilical cord clamping. This study was designed to compare the impact of using two different times for cord clamping on hematocrit concentration and Apgar scores of the neonate. Fifty-six healthy full-term vaginally born neonates were allocated to early (10 seconds after delivery) and late (3 minutes after delivery) umbilical cord clamping groups in this randomized clinical trial. We recorded the length of the 3rd stage of labor and Apgar score at 5 minutes. Infant's hematocrit was measured at 2 and 18 hours of age. Neonatal hematocrit differed between the two groups. Late cord clamping group had greater hematocrit at 2 hours (45.5 ± 4 vs. 49.5 ± 4.4, P = 0.0003) and 18 hours (47.7 ± 5.5 vs. 52.9 ± 4.3, P = 0.0002). Apgar scores at 5 minutes (9.3 ± 0.6 vs. 9.4 ± 0.6, p = 0.5) and duration of delivery 3rd stage (10.2 ± 3.7 min vs. 8.9 ± 5 min, P = 0.2) did not differ between early and late cord clamping groups respectively. Late cord clamping leads to a significant increase in the hematocrit of the neonate but it does not have effects on Apgar score and duration of the 3rd stage of labor.

  11. Can selective arterial clamping with fluorescence imaging preserve kidney function during robotic partial nephrectomy?

    Science.gov (United States)

    McClintock, Tyler R; Bjurlin, Marc A; Wysock, James S; Borofsky, Michael S; Marien, Tracy P; Okoro, Chinonyerem; Stifelman, Michael D

    2014-08-01

    To compare renal functional outcomes in robotic partial nephrectomy (RPN) with selective arterial clamping guided by near-infrared fluorescence (NIRF) imaging to a matched cohort of patients who underwent RPN without selective arterial clamping and NIRF imaging. From April 2011 to December 2012, NIRF imaging-enhanced RPN with selective clamping was used in 42 cases. Functional outcomes of successful cases were compared with a cohort of patients, matched by tumor size, preoperative estimated glomerular filtration rate (eGFR), functional kidney status, age, sex, body mass index, and American Society of Anesthesiologists score, who underwent RPN without selective clamping and NIRF imaging. In matched-pair analysis, selective clamping with NIRF was associated with superior kidney function at discharge, as demonstrated by postoperative eGFR (78.2 vs 68.5 mL/min/1.73 m(2); P = .04), absolute reduction of eGFR (-2.5 vs -14.0 mL/min/1.73 m(2); P functional outcomes when compared with RPN without selective arterial clamping and NIRF imaging. With this effect attenuated at later follow-up, randomized prospective studies and long-term assessment of kidney-specific functional outcomes are needed to further assess the benefits of this technology. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Precise control of clamping force for watermelon picking end-effector%西瓜采摘末端执行器夹持力精确控制

    Institute of Scientific and Technical Information of China (English)

    胡志勇; 张学炜; 张伟; 王琳

    2014-01-01

    为实现西瓜的机械化采摘,该文提出了采用液压驱动型末端执行器采摘大型果实的思路。在抓取西瓜时,为避免末端执行器夹持力不稳定引起的果实损伤,需对夹持力进行精确控制,该文建立了末端执行器负载模拟平台和AMESim&Simulink联合仿真模型,模拟西瓜采摘夹持力的加载情况。针对执行器夹持力加载过程中位置控制系统对力控制系统产生干扰,影响夹持力精确加载的问题,该文基于速度同步控制原理,设计了简化的加载误差补偿环节,开展了加载误差补偿理论、仿真及试验研究。结果表明,速度同步控制方法能够有效地减小加载误差,提高末端执行器负载模拟精度。该研究可为末端执行器输出力的精确控制和抓取控制策略提供参考。%Certain agricultural work requires a very stable robot end-effector to reduce vibration and damage to products. However, the structures of conventional articulated robots tend to be too weak to manipulate heavy objects, such as the watermelon. To achieve mechanized harvesting of the watermelon, we compared the characteristics of different end-effectors with the motor, pneumatic and hydraulic drives. By contrast, the hydraulic drive has many advantages, such as high power-weight ratio, compact structure and convenient layout. Therefore, the end-effector with hydraulic drive is more suitable for heavy fruit harvesting such as the watermelon. The hydraulic drive system based on force perception can output appropriate clamping force according to actual situation. When picking robot crawls and picks, it needs to avoid the damage to fruits and vegetables caused by unstable clamping force and to achieve the precise control of the clamping force for picking robot end-effector. Therefore, how to improve output force’s control precision of the valve control cylinder and reduce interference are key to improve the picking performance. Two

  13. The Formation of the Surface during AN Abrasive Finishing at Constant and Variable Clamping Forces: Finishing at Constant and Variable Clamping Forces

    Science.gov (United States)

    Muratov, Karim Ravilevich; Muratov, Ravil Arifovich; Ablyaz, Timur Rizovich; Gashev, Evgeniy Anatolyevich

    2017-06-01

    In this work the flat abrasive finishing process is reported. The mechanical and chemical phenomena taking place during the finishing process are described. The most common forming process schemes observed during abrasive treatment are reviewed. The schemes of pulsed, geometrical and energetic models are discussed. On the basis of the energetic hypothesis and Preston hypothesis, the rational law of clamping force variation during the finishing is established. This law allowed for the stabilization of the contact pressure and an increase of the treatment efficiency. An exponential dependence of a boundary contact area variation during the finishing of planes with different initial profiles of the macro-topography is developed. An experimental confirmation of the Preston hypothesis during the abrasive finishing is carried out with the plane-finishing machine “Rastr 220”. The comparison experiments are carried out at constant and variable clamping forces of the treated surface towards the tool. It is found that by varying the forces according to the exponential law (i.e. similar to the changing of the boundary contact area during the abrasive finishing) the process efficiency is increasing by a factor of 2.5-3. It is shown that the changes of the root mean square deviation σ of the roughness Ra of a treated surface in the beginning of the process (at time t=1 min) during the finishing at a constant clamping force is two times higher compared to the treatment at a variable clamping force in the same time period.

  14. M. tuberculosis sliding β-clamp does not interact directly with the NAD+-dependent DNA ligase.

    Directory of Open Access Journals (Sweden)

    Vandna Kukshal

    Full Text Available The sliding β-clamp, an important component of the DNA replication and repair machinery, is drawing increasing attention as a therapeutic target. We report the crystal structure of the M. tuberculosis β-clamp (Mtbβ-clamp to 3.0 Å resolution. The protein crystallized in the space group C222(1 with cell-dimensions a = 72.7, b = 234.9 & c = 125.1 Å respectively. Mtbβ-clamp is a dimer, and exhibits head-to-tail association similar to other bacterial clamps. Each monomer folds into three domains with similar structures respectively and associates with its dimeric partner through 6 salt-bridges and about 21 polar interactions. Affinity experiments involving a blunt DNA duplex, primed-DNA and nicked DNA respectively show that Mtbβ-clamp binds specifically to primed DNA about 1.8 times stronger compared to the other two substrates and with an apparent K(d of 300 nM. In bacteria like E. coli, the β-clamp is known to interact with subunits of the clamp loader, NAD(+-dependent DNA ligase (LigA and other partners. We tested the interactions of the Mtbβ-clamp with MtbLigA and the γ-clamp loader subunit through radioactive gel shift assays, size exclusion chromatography, yeast-two hybrid experiments and also functionally. Intriguingly while Mtbβ-clamp interacts in vitro with the γ-clamp loader, it does not interact with MtbLigA unlike in bacteria like E. coli where it does. Modeling studies involving earlier peptide complexes reveal that the peptide-binding site is largely conserved despite lower sequence identity between bacterial clamps. Overall the results suggest that other as-yet-unidentified factors may mediate interactions between the clamp, LigA and DNA in mycobacteria.

  15. Vibrations of hydraulic pump and their solution

    OpenAIRE

    Dobšáková Lenka; Nováková Naděžda; Habán Vladimír; Hudec Martin; Jandourek Pavel

    2017-01-01

    The vibrations of hydraulic pump and connected pipeline system are very problematic and often hardly soluble. The high pressure pulsations of hydraulic pump with the double suction inlet are investigated. For that reason the static pressure and accelerations are measured. The numerical simulations are carried out in order to correlate computed data with experimental ones and assess the main source of vibrations. Consequently the design optimization of the inner hydraulic part of pump is done ...

  16. Design and Analysis of Hydraulic Chassis with Obstacle Avoidance Function

    Science.gov (United States)

    Hong, Yingjie; Zhang, Xiang

    2017-07-01

    This article mainly expounds the design of hydraulic system for the hydraulic chassis with obstacle avoidance function. Including the selection of hydraulic motor wheels, hydraulic pump, digital hydraulic cylinder and the matching of engine power. And briefly introduces the principle of obstacle avoidance.

  17. A central swivel point in the RFC clamp loader controls PCNA opening and loading on DNA.

    Science.gov (United States)

    Sakato, Miho; O'Donnell, Mike; Hingorani, Manju M

    2012-02-17

    Replication factor C (RFC) is a five-subunit complex that loads proliferating cell nuclear antigen (PCNA) clamps onto primer-template DNA (ptDNA) during replication. RFC subunits belong to the AAA(+) superfamily, and their ATPase activity drives interactions between the clamp loader, the clamp, and the ptDNA, leading to topologically linked PCNA·ptDNA. We report the kinetics of transient events in Saccharomyces cerevisiae RFC-catalyzed PCNA loading, including ATP-induced RFC activation, PCNA opening, ptDNA binding, ATP hydrolysis, PCNA closing, and PCNA·ptDNA release. This detailed perspective enables assessment of individual RFC-A, RFC-B, RFC-C, RFC-D, and RFC-E subunit functions in the reaction mechanism. Functions have been ascribed to RFC subunits previously based on a steady-state analysis of 'arginine-finger' ATPase mutants; however, pre-steady-state analysis provides a different view. The central subunit RFC-C serves as a critical swivel point in the clamp loader. ATP binding to this subunit initiates RFC activation, and the clamp loader adopts a spiral conformation that stabilizes PCNA in a corresponding open spiral. The importance of RFC subunit response to ATP binding decreases as RFC-C>RFC-D>RFC-B, with RFC-A being unnecessary. RFC-C-dependent activation of RFC also enables ptDNA binding, leading to the formation of the RFC·ATP·PCNA(open)·ptDNA complex. Subsequent ATP hydrolysis leads to complex dissociation, with RFC-D activity contributing the most to rapid ptDNA release. The pivotal role of the RFC-B/C/D subunit ATPase core in clamp loading is consistent with the similar central location of all three ATPase active subunits of the Escherichia coli clamp loader.

  18. Timing of umbilical cord-clamping and infant anaemia: the role of maternal anaemia.

    Science.gov (United States)

    Blouin, Brittany; Penny, Mary E; Maheu-Giroux, Mathieu; Casapía, Martín; Aguilar, Eder; Silva, Hermánn; Creed-Kanashiro, Hilary M; Joseph, Serene A; Gagnon, Anita; Rahme, Elham; Gyorkos, Theresa W

    2013-05-01

    Evidence from randomized controlled trials has shown that delayed cord-clamping is beneficial to infant iron status. The role of maternal anaemia in this relationship, however, has not been established. To determine the effect of maternal anaemia at delivery on the association between timing of umbilical cord-clamping and infant anaemia at 4 and 8 months of age. A cohort of pregnant women admitted to the labour room of Hospital Iquitos (Iquitos, Peru) and their newborns were recruited into the study during two time periods (18 May to 3 June and 6-20 July 2009). Between the two recruitment periods, the hospital's policy changed from early to delayed umbilical cord-clamping. Maternal haemoglobin levels were measured before delivery, and the time between delivery and cord-clamping was recorded at delivery for the entire cohort. Mother-infant pairs were followed-up at 4 (n = 207) and 8 months (n = 184) post partum. Infant haemoglobin levels were measured at follow-up visits. Data were analysed using logistic regression models. The prevalence of maternal anaemia (Hb cord-clamping and infant anaemia was modified by the mother's anaemia status. Significant benefits of delayed cord-clamping in preventing anaemia were found in infants born to anaemic mothers at both 4 months (aOR = 0.59, 95% CI 0.36-0.99) and 8 months (aOR = 0.38, 95% CI 0.19-0.76) of age. The study contributes additional evidence in support of delayed cord-clamping. This intervention is likely to have most public health impact in areas with a high prevalence of anaemia during pregnancy.

  19. Timing of umbilical cord clamping after birth for optimizing placental transfusion.

    Science.gov (United States)

    Raju, Tonse N K

    2013-04-01

    A brief delay in clamping the umbilical cord after birth offers health benefits to the newborn, with no adverse effects to the mother or her infant. Yet, in most obstetric practice, the cord is clamped soon after birth. A summary of the current evidence on delayed cord clamping and some reasons for the disconnect between the evidence and practice are discussed here, along with the recommendations from professional organizations and societies about this practice. In term infants, umbilical cord clamping between 30 and 180 s after birth results in higher concentrations of hemoglobin and hematocrit during the neonatal period, and increased serum ferritin levels and a lower incidence of iron-deficiency anemia at 4-6 months of age. These are important benefits for children in low and middle income countries where iron-deficiency anemia is highly prevalent. In preterm infants, delayed cord clamping for at least 30 s increases the concentrations of hemoglobin and hematocrit, improves mean systemic blood pressure, urine output, and cardiac function, and decreases the need for vasopressors and blood transfusions during the neonatal period. It also decreases the prevalence of necrotizing enterocolitis, sepsis, and intraventricular hemorrhage (all grades). Milking of the unclamped umbilical cord toward the infant soon after birth also has similar beneficial effects. In some studies, more infants in the delayed cord clamping groups required phototherapy for jaundice. Many professional organizations, societies, and experts recommend at least a 30-s delay before clamping the umbilical cord, especially after preterm births. The value of this practice for term births in resource-rich settings has not been evaluated.

  20. Umbilical cord blood acid-base and gas analysis after early versus delayed cord clamping in neonates at term.

    Science.gov (United States)

    De Paco, Catalina; Florido, Jesús; Garrido, Mari Carmen; Prados, Sonia; Navarrete, Luis

    2011-05-01

    To compare umbilical cord acid-base status and blood gas analysis between umbilical cords clamped within 10 s and at 2 min of delivery. A total of 158 healthy full-term mothers were randomly assigned to an early clamping (clamping (2 min post-delivery, n = 79) group. After application of inclusion criteria, umbilical vein blood acid-base status and gases were analyzed in 65 early clamped and 51 delayed clamped cords. Fewer cases could be examined in the umbilical artery: 55 cords in the early clamping group and 44 in the delayed one. Acid-base and gas analysis results did not significantly differ between the groups in the umbilical vein or umbilical artery, with the exception of a higher (p umbilical artery pO(2) value in the delayed versus early clamping group. No significant differences in umbilical vein or artery pCO(2) or HCO(3) (-) values were observed between the early and delayed clamp groups. A delay of 2 min before umbilical cord clamping does not significantly change acid-base and gas analysis results, with the exception of a higher mean umbilical artery pO(2) value in the delayed clamping group.

  1. Helical coil thermal hydraulic model

    Science.gov (United States)

    Caramello, M.; Bertani, C.; De Salve, M.; Panella, B.

    2014-11-01

    A model has been developed in Matlab environment for the thermal hydraulic analysis of helical coil and shell steam generators. The model considers the internal flow inside one helix and its associated control volume of water on the external side, both characterized by their inlet thermodynamic conditions and the characteristic geometry data. The model evaluates the behaviour of the thermal-hydraulic parameters of the two fluids, such as temperature, pressure, heat transfer coefficients, flow quality, void fraction and heat flux. The evaluation of the heat transfer coefficients as well as the pressure drops has been performed by means of the most validated literature correlations. The model has been applied to one of the steam generators of the IRIS modular reactor and a comparison has been performed with the RELAP5/Mod.3.3 code applied to an inclined straight pipe that has the same length and the same elevation change between inlet and outlet of the real helix. The predictions of the developed model and RELAP5/Mod.3.3 code are in fairly good agreement before the dryout region, while the dryout front inside the helical pipes is predicted at a lower distance from inlet by the model.

  2. WATER ENERGY IN HYDROAMELIORATIVE SYSTEMS USING THE HYDRAULIC TRANSFORMER TYPE A. BARGLAZAN AND THE HYDRAULIC HAMMER (HYDRAULIC PUMP

    Directory of Open Access Journals (Sweden)

    Teodor Eugen Man

    2010-01-01

    Full Text Available This paper presents two examples of exploitation of water energy that can be used in the irrigation field. First of theseexamples is the hydraulic transformer type A. Barglazan used for irrigation, pumped water is taken directly from theriver’s well, using a hydraulic pump which simultaneously carried out a double transformation in this way: hydraulicenergy into mechanic energy and mechanical energy into hydraulic energy. Technology preparation and devices designwas done in record time, seeing that this constructive solution is more robust, reliable and with improved energyperformance versus the laboratory prototype. The experimental research which was made at 1:1 scale proved theirgood function over time. Another example is the hydraulic hammer (hydraulic pump that uses low-head energy topump water, with a global efficiency of about 10 - 50%. Currently, the new situation of private ownership of landprovides conditions for new pumping microstations to be made where irrigation is necessary and optimal hydrauliclocations exist.

  3. Clampe de Ganz no tratamento de urgência em lesões do anel pélvico Ganz clamps to treat emergencies in pelvic ring lesions

    Directory of Open Access Journals (Sweden)

    Gilberto José Cação Pereira

    2008-07-01

    Full Text Available OBJETIVO: Avaliar a eficiência do clampe de Ganz na estabilização e redução dos deslocamentos da pelve, quando utilizado no tratamento de urgência, além de aquilatar eventuais dificuldades e facilidades do método. MÉTODOS: O clampe de Ganz foi utilizado no tratamento de urgência em 31 pacientes com graves lesões do anel pélvico (Tile C associadas a importante instabilidade hemodinâmica. RESULTADO: Entre os pacientes, 27 (87,1% apresentaram evolução favorável, com estabilização, redução dos deslocamentos e compressão da região posterior do anel, além de estabilização hemodinâmica, e quatro (12,9% evoluíram para óbito. CONCLUSÃO: O clampe de Ganz mostrou-se eficiente ferramenta no tratamento de urgência das lesões do anel pélvico, por ser de concepção simples, de rápida colocação, não impedir ou dificultar procedimentos no abdome e, principalmente, por permitir a estabilização da pelve, redução dos deslocamentos e compressão na região posterior do anel, local onde ocorrem os maiores sangramentos, reduzindo-os ou eliminando-os.OBJECTIVE: To evaluate the effectiveness of Ganz clamp to stabilize and reduce pelvic dislocations in emergency situations, and to assess possible difficult and easy aspects of the method. METHOD: Ganz clamp was used in the emergency treatment of 31 patients with severe lesions of the pelvic ring (Tile C associated to major hemodynamic instability. RESULTS: Among the patients, 27 (87.1% presented a favorable evolution, with stabilization, reduction of dislocations, and compression of the posterior portion of the ring, and also hemodynamic stabilization, and 4 (12.9% died. CONCLUSION: The Ganz clamp was found to be an effective tool in the emergency treatment of pelvic ring lesions because it has an uncomplicated conception, allowing for a fast placement, because it does not prevent nor make it difficult for abdominal procedures, and most of all because it allows for the

  4. Incision Below The Clamp sebagai Modifikasi Teknik Insisi pada Frenektomi untuk Minimalisasi Perdarahan

    Directory of Open Access Journals (Sweden)

    S. Suryono

    2016-10-01

    Full Text Available Latar Belakang. Perlekatan frenulum tinggi berdampak merugikan bagi jaringan periodontal maupun fungsi estetik. Perlekatan tinggi yang terjadi pada labialis superior, menimbulkan gingivitis dan sentral diastema yang menjadikan indikasi untuk dilakukan frenektomi. Frenektomi dengan teknik melakukan insisi di atas dan di bawah clamp berakibat lebarnya luka karena tarikan otot bibir, yang berdampak terjadi banyak perdarahan. Tujuan. Melakukan evaluasi terhadap modifikasi teknik insisi yang diharapkan dapat mengurangi perdarahan. Kasus dan Penanganan. Laporan kasus ini memaparkan penanganan kasus pada perlekatan frenulum tinggi yang diikuti adanya sentral diastema. Pasien dengan diagnosa frenulum tinggi dan indikasi frenektomi dilakukan tindakan preoperasi. Tindakan operasi dilakukan dengan menggunakan pisau bedah, modifikasi insisi (Insision below the Clamp dilakukan dengan cara menempatkan clamp frenulum pada posisi yang berdekatan dan sejajar dengan bibir, tindakan insisi dilakukan di bawah clamp, disusul dengan penjahitan pada area mucolabial fold. Selama operasi dilakukan terlihat luka tidak melebar, tidak banyak darah yang keluar, pasien dan dokter merasa nyaman. Kesimpulan. Insision below the Clamp merupakan modifikasi teknik insisi pada frenektomi yang bisa dilakukan oleh para praktisi untuk meminimalisir perdarahan yang terjadi selama proses pengambilan frenulum dengan menggunakan pisau bedah.   Background. Attachment of high frenulum has negative impact on periodontal tissues as well as an aesthetic function. High attachment of frenulum that occurs in labialis superior, causing gingivitis and central diastema that are indications to do Frenectomy. Conventional techniques of Frenectomy performed with insisions above and below the clamp resulted in wide injury due to muscle contraction, which affects a lot of bleeding. Objective. To evaluate modification insision technique which hopefully can minimize the bleeding. Case and Treatment. This

  5. Reserch of unilateral clamping lifting tool of great steel tube stake at sea%海上大型基础钢桩单边夹持吊具的研究

    Institute of Scientific and Technical Information of China (English)

    李挺前

    2013-01-01

    A unilateral clamping suspension tool was researched for tube stake installation of marine fan impeller and it is able to lift great steel tube stake .First of all,it carried out the structural design of the suspension tool and described the its working prin -ciple;Secondly ,the force state of suspension tool clamping was analyzed and the hydraulic and the dead load cam clamping mech -anism were designed and also analyzed the clamping force;Finally,it developed the prototype and carried out hanging tube experi-ments to verify the rationality and reliability of the design of prototype and lay the theoretical and practice foundation for the de -sign of engineering prototype .%针对海上风机叶轮大型基础钢桩的安装作业,进行了一种单边夹持吊具的研究,能够实现大型基础钢桩的海上吊装操作。首先,进行了单边夹持吊具的结构设计并阐述了工作原理;其次,分析了吊具夹紧受力状态,研究了液压缸凸轮与自重凸轮夹紧机构,进行了夹紧力分析;最后,研制了模型样机并进行了吊桩实验,验证了方案设计的合理性与可靠性,为工程样机的设计打下了理论与实践基础。

  6. HYDRAULIC CHARACTERISTICS OF VERTICAL VORTEX AT HYDRAULIC INTAKES

    Institute of Scientific and Technical Information of China (English)

    CHEN Yun-liang; WU Chao; YE Mao; JU Xiao-ming

    2007-01-01

    The trace of vertical vortex flow at hydraulic intakes is of the shape of spiral lines, which was observed in the presented experiments with the tracer technique. It represents the fluid particles flow spirally from the water surface to the underwater and rotate around the vortex-axis multi-cycle. This process is similar to the movement of screw. To describe the multi-circle spiral characteristics under the axisymmetric condition, the vertical vortex would change not only in the radial direction but also in the axial direction. The improved formulae for three velocity components for the vertical vortex flow were deduced by using the method of separation of variables in this article. In the improved formulae, the velocity components are the functions of the radial and axial coordinates, so the multi-circle spiral flow of vertical vortex could be simulated. The calculated and measured results for the vertical vortex flow were compared and the causes of errors were analyzed.

  7. Novel Low Loss Active Voltage Clamp Circuit for Series Connection of RCGCT thyristors

    Science.gov (United States)

    Ito, Hiroshi; Suzuki, Akihiro; Iwata, Akihiko

    This paper describes novel low loss active voltage clamp circuits for the series connection of RCGCT thyristors. For high voltage converters the series connection of power semiconductor devices is an essential technique for direct switching of high voltages. Several protection circuits have been applied to the series connection of RCGCT thyristors such as CRD snubber circuits which suppress over-voltages across RCGCT thyristors, and voltage balancing resistors to equalize voltage sharing in steady states. However, significant losses in these protection circuits lower the converter’s efficiency. We propose novel low-loss protection circuits, which have active voltage clamp snubber circuits and static voltage balancing circuits. The clamp capacitor voltage of the active voltage clamp snubber circuits are designed to be higher than the equally divided DC-Link voltage. This method can reduce the loss of the clamp circuit to no more than 1/10 of that of the conventional CRD snubber. Also the static voltage balancing circuits compensate for the voltage imbalance generated by the difference in the leakage current between the series connection RCGCT thyristors.

  8. Gain-clamping techniques in two-stage double-pass L-band EDFA

    Indian Academy of Sciences (India)

    S W harun; N Md Samsuri; H Ahmad

    2006-03-01

    Two designs of long-wavelength band erbium-doped fiber amplifier (L-band EDFA) for gain clamping in double-pass systems are demonstrated and compared. The first design is based on ring laser technique where a backward amplified spontaneous emission (ASE) from the second stage is routed into the feedback loop to create an oscillating laser for gain clamping. The gain is clamped at 18.6 dB from -40 to -8 dBm with a gain variation of less than ± 0.1 dB and a noise figure of less than 6 dB. Another scheme is based on partial reflection of ASE into the EDFA, which is demonstrated using a narrowband fiber Bragg grating. This scheme achieves a good gain clamping characteristic up to -12 dBm of input signal power with a gain variation of less than ± 0.3 dB from a clamped gain of 22 dB. The noise figure of a 1580 nm signal is maintained below 5 dB in this amplifier since this scheme is not based on lasing mechanism. The latter scheme is also expected to be free from the relaxation oscillation problem.

  9. Effect of timing of umbilical cord clamping of term infants on maternal and neonatal outcomes.

    Science.gov (United States)

    McDonald, Susan J; Middleton, Philippa; Dowswell, Therese; Morris, Peter S

    2013-07-11

    Policies for timing of cord clamping vary, with early cord clamping generally carried out in the first 60 seconds after birth, whereas later cord clamping usually involves clamping the umbilical cord more than one minute after the birth or when cord pulsation has ceased. The benefits and potential harms of each policy are debated. To determine the effects of early cord clamping compared with late cord clamping after birth on maternal and neonatal outcomes We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (13 February 2013). Randomised controlled trials comparing early and late cord clamping. Two review authors independently assessed trial eligibility and quality and extracted data. We included 15 trials involving a total of 3911 women and infant pairs. We judged the trials to have an overall moderate risk of bias. Maternal outcomes: No studies in this review reported on maternal death or on severe maternal morbidity. There were no significant differences between early versus late cord clamping groups for the primary outcome of severe postpartum haemorrhage (risk ratio (RR) 1.04, 95% confidence interval (CI) 0.65 to 1.65; five trials with data for 2066 women with a late clamping event rate (LCER) of ~3.5%, I(2) 0%) or for postpartum haemorrhage of 500 mL or more (RR 1.17 95% CI 0.94 to 1.44; five trials, 2260 women with a LCER of ~12%, I(2) 0%). There were no significant differences between subgroups depending on the use of uterotonic drugs. Mean blood loss was reported in only two trials with data for 1345 women, with no significant differences seen between groups; or for maternal haemoglobin values (mean difference (MD) -0.12 g/dL; 95% CI -0.30 to 0.06, I(2) 0%) at 24 to 72 hours after the birth in three trials. Neonatal outcomes: There were no significant differences between early and late clamping for the primary outcome of neonatal mortality (RR 0.37, 95% CI 0.04 to 3.41, two trials, 381 infants with a LCER of ~1%), or for most other

  10. Delayed Umbilical Cord Blood Clamping: First Line of Defense Against Neonatal and Age-Related Disorders.

    Science.gov (United States)

    Sanberg, Paul R; Divers, Ryan; Mehindru, Anuj; Mehindru, Ankur; Borlongan, Cesar V

    2014-06-01

    The aging body is unable to maintain homeostasis in cell genesis and function. Stem cell-based regenerative medicine may reverse aging and treat age-related disorders. This perspective article discusses the therapeutic effects of stem cell transplantation on neonatal diseases, which may have long-lasting benefits affecting even the aging process. In particular, the article highlights the potential of the earliest transfer of stem cells between a mother and fetus via the umbilical cord during child birth and how this process may modify the clinical practice of umbilical cord clamping. While such umbilical cord clamping is routinely performed in an expeditious manner after birth for stem cell banking, the present article advances the concept that a delay in clamping the umbilical cord may actually allow more stem cells to be delivered from the mother to the fetus. The authors' overarching hypothesis is that early umbilical cord clamping results in an artificial loss of stem cells at birth and increases the infant's susceptibility to both neonatal and age-related diseases, while delaying umbilical cord clamping is perhaps the most effective and non-invasive way to transplant stem cells in order to treat these diseases.

  11. Trail without Catheter after Transurethral Resection of Prostate: Clamp It or Not?

    Directory of Open Access Journals (Sweden)

    Vikash Talreja

    2016-01-01

    Full Text Available Background. There has been argument between clinical practitioners about clamping catheter or not prior to its removal after transurethral resection of prostate (TURP. We conducted a clinical trial to assess whether clamping has any role in early bladder tone recovery particularly in patients who undergo TURP. Methods. Randomized clinical trial was conducted at a tertiary care hospital, Karachi from January 2014 to July 2015. Eighty-six study participants who underwent TURP were randomly allocated into two groups of 43 participants each. In Group I, patient’s Foley catheter was not clamped prior to its removal and in Group II Foley catheter was clamped. Data of all subjects were analyzed using SPSS version 20. Results. There was no significant difference in age and weight of resected tissues between two groups. Among 4 patients in Group I who required recatheterization, 1 patient was discharged with catheter as compared to Group II in which 2 patients were discharged with catheter (P=0.99. Only 1 patient (2.3% in Group II had bleeding which required recatheterization. Length of stay was significantly affected by early and free removal of Foley catheter (P<0.001. Conclusion. The results of current study identified that clamping whether done or not had no significant impact on urinary retention.

  12. Functional dissection of synaptic circuits: in vivo patch-clamp recording in neuroscience

    Directory of Open Access Journals (Sweden)

    Can eTao

    2015-05-01

    Full Text Available Neuronal activity is dominated by synaptic inputs from excitatory or inhibitory neural circuits. With the development of in vivo patch-clamp recording, especially in vivo voltage-clamp recording, researchers can not only directly measure neuronal activity, such as spiking responses or membrane potential dynamics, but also quantify synaptic inputs from excitatory and inhibitory circuits in living animals. This approach enables researchers to directly unravel different synaptic components and to understand their underlying roles in particular brain functions. Combining in vivo patch-clamp recording with other techniques, such as two-photon imaging or optogenetics, can provide even clearer functional dissection of the synaptic contributions of different neurons or nuclei. Here, we summarized current applications and recent research progress using the in vivo patch-clamp recording method and focused on its role in the functional dissection of different synaptic inputs. The key factors of a successful in vivo patch-clamp experiment and possible solutions based on references and our experiences were also discussed.

  13. Design of Pumps for Water Hydraulic Systems

    DEFF Research Database (Denmark)

    Klit, Peder; Olsen, Stefan; Bech, Thomas Nørgaard

    1999-01-01

    This paper considers the development of two pumps for water hydraulic applications. The pumps are based on two different working principles: The Vane-type pump and the Gear-type pump. Emphasis is put on the considerations that should be made to account for water as the hydraulic fluid.......KEYWORDS: water, pump, design, vane, gear....

  14. Hydraulic fracturing with distinct element method

    NARCIS (Netherlands)

    Pruiksma, J.P.; Bezuijen, A.

    2002-01-01

    In this report, hydraulic fracturing is investigated using the distinct element code PFC2D from Itasca. Special routines were written to be able to model hydraulic fracturing. These include adding fluid flow to PFC2D and updating the fluid flow domains when fractures appear. A brief description of t

  15. Hydraulic Actuator for Ganged Control Rods

    Science.gov (United States)

    Thompson, D. C.; Robey, R. M.

    1986-01-01

    Hydraulic actuator moves several nuclear-reactor control rods in unison. Electromagnetic pump pushes liquid lithium against ends of control rods, forcing them out of or into nuclear reactor. Color arrows show lithium flow for reactor startup and operation. Flow reversed for shutdown. Conceived for use aboard spacecraft, actuator principle applied to terrestrial hydraulic machinery involving motion of ganged rods.

  16. Control arrangement for the actuation of hydraulic consumers

    Energy Technology Data Exchange (ETDEWEB)

    Kussel, W.; Dettmers, M.; Weirich, W.

    1988-11-09

    An arrangement for controlling the actuation of hydraulic consumers, by selectively connecting the consumers to hydraulic pressure and return lines; the control arrangement comprising a respective hydraulically operated directional control valve associated with each of the hydraulic consumers, a respective electro-magnetically operated pre-control valve associated with each of the hydraulic directional control valves, and further electro-magnetically operated directional control valve means associated with the pre-control valves, each of the hydraulic consumers being connectible to the hydraulic pressure or return lines via the associated hydraulically operated directional control valve which is actuatable by a hydraulic control line leading from the output of the associated pre-control valve, wherein the inputs of the pre-control valves are connected directly to the hydraulic return line and indirectly, via the further control valve means, to the hydraulic return line or to a hydraulic control pressure line.

  17. Gravity-Driven Hydraulic Fractures

    Science.gov (United States)

    Germanovich, L. N.; Garagash, D.; Murdoch, L. C.; Robinowitz, M.

    2014-12-01

    This study is motived by a new method for disposing of nuclear waste by injecting it as a dense slurry into a hydraulic fracture that grows downward to great enough depth to permanently isolate the waste. Disposing of nuclear waste using gravity-driven hydraulic fractures is mechanically similar to the upward growth of dikes filled with low density magma. A fundamental question in both applications is how the injected fluid controls the propagation dynamics and fracture geometry (depth and breadth) in three dimensions. Analog experiments in gelatin [e.g., Heimpel and Olson, 1994; Taisne and Tait, 2009] show that fracture breadth (the short horizontal dimension) remains nearly stationary when the process in the fracture "head" (where breadth is controlled) is dominated by solid toughness, whereas viscous fluid dissipation is dominant in the fracture tail. We model propagation of the resulting gravity-driven (buoyant or sinking), finger-like fracture of stationary breadth with slowly varying opening along the crack length. The elastic response to fluid loading in a horizontal cross-section is local and can be treated similar to the classical Perkins-Kern-Nordgren (PKN) model of hydraulic fracturing. The propagation condition for a finger-like crack is based on balancing the global energy release rate due to a unit crack extension with the rock fracture toughness. It allows us to relate the net fluid pressure at the tip to the fracture breadth and rock toughness. Unlike the PKN fracture, where breadth is known a priori, the final breadth of a finger-like fracture is a result of processes in the fracture head. Because the head is much more open than the tail, viscous pressure drop in the head can be neglected leading to a 3D analog of Weertman's hydrostatic pulse. This requires relaxing the local elasticity assumption of the PKN model in the fracture head. As a result, we resolve the breadth, and then match the viscosity-dominated tail with the 3-D, toughness

  18. The Effect of an Added Mass on the Frequency Shifts of a Clamped-Clamped Microbeam for Bio-Mass Detection

    KAUST Repository

    Bouchaala, Adam M.

    2016-12-05

    We present analytical formulations to calculate the induced resonance frequency shifts of electrically actuated clamped-clamped microbeams due to an added mass. Based on the Euler-Bernoulli beam theory, we investigate the linear dynamic responses of the beams added masses, which are modeled as discrete point masses. Analytical expressions based on perturbation techniques and a one-mode Galerkin approximation are developed to calculate accurately the frequency shifts under a DC voltage as a function of the added mass and position. The analytical results are compared to numerical solution of the eigenvalue problem. Results are shown for the fundamental as well as the higher-order modes of the beams. The results indicate a significant increase in the frequency shift, and hence the sensitivity of detection, when scaling down to nano scale and using higher-order modes.

  19. Scaling hydraulic properties of a macroporous soil

    Science.gov (United States)

    Mohanty, Binayak P.

    1999-06-01

    Macroporous soils exhibit significant differences in their hydraulic properties for different pore domains. Multimodal hydraulic functions may be used to describe the characteristics of multiporosity media. I investigated the usefulness of scaling to describe the spatial variability of hydraulic conductivity (K(-h)) functions of a macroporous soil in Las Nutrias, New Mexico. Piecewise-continuous hydraulic conductivity functions suitable for macroporous soils in conjunction with a hybrid similar media-functional normalization scaling approach were used. Results showed that gravity-dominated flow and the related hydraulic conductivity (K(minus;h) functions of the macropore region are more readily scalable than capillary-dominated flow properties of the mesopore and micropore regions. A possible reason for this behavior is that gravity-dominated flow in the larger pores is mostly influenced by the pore diameter which remains more uniform as compared to tortuous mesopores and micropores with variable neck and body sizes along the pore length.

  20. Hydraulic conductivity of GCLs in MSW landfills

    Institute of Scientific and Technical Information of China (English)

    LI Guo-cheng; YANG Wu-chao; DAN Tang-hui

    2008-01-01

    The state of the art of the study on the hydraulic conductivity of GCLs is presented in terms of the in-fluence of the effective stress, chemical interactions, freeze - thaw cycles and temperature gradients. The chan-ges of void ratio caused by changes of effective stress have a direct linear effect on the hydraulic conductivity, regardless of the cation concentration or the thickness of the adsorbed layer. The hydraulic conductivity is relat-ed to the relative abundance of monovalent and divalent cation(RMD), and RMD has a great effect on the hy-draulic conductivity in weak solution. The long-term susceptibility of GCLs to increased hydraulic conductivity as a response to repeated freeze-thaw cycling is minimal, which has been proved after 150 freeze-thaw cycles. The potential of desiccation cracking increases with the increasing temperature gradient and is related to the ini-tial subsoil water content, the applied overburden stress, etc.

  1. Modeling and Simulation of Hydraulic Engine Mounts

    Institute of Scientific and Technical Information of China (English)

    DUAN Shanzhong; Marshall McNea

    2012-01-01

    Hydraulic engine mounts are widely used in automotive powertrains for vibration isolation.A lumped mechanical parameter model is a traditional approach to model and simulate such mounts.This paper presents a dynamical model of a passive hydraulic engine mount with a double-chamber,an inertia track,a decoupler,and a plunger.The model is developed based on analogy between electrical systems and mechanical-hydraulic systems.The model is established to capture both low and high frequency dynatmic behaviors of the hydraulic mount.The model will be further used to find the approximate pulse responses of the mounts in terms of the force transmission and top chamber pressure.The close form solution from the simplifiod linear model may provide some insight into the highly nonlinear behavior of the mounts.Based on the model,computer simulation has been carried out to study dynamic performance of the hydraulic mount.

  2. Hydraulic test for evaluation of hydrophone VSP

    Energy Technology Data Exchange (ETDEWEB)

    Yabuuchi, Satoshi; Koide, Kaoru [Power Reactor and Nuclear Fuel Development Corp., Toki, Gifu (Japan). Tono Geoscience Center

    1997-12-01

    This hydraulic test was carried out at the test site of Tono Geoscience Center, Mizunami-shi, Gifu Pref. in order to evaluate the reliability of the hydraulic conductivity estimated from hydrophone VSP experiment. From March to April 1997, we carried out measurements of pore-water pressure at five depths and permeability tests at seven depths down to G.L.-300m, within a borehole drilled in granitic rock. We compared the results of hydraulic test with hydrophone VSP experiment on condition that a single open fracture existed, and we obtained two notable results. First, for the granitic rock at which a single open fracture was found by BTV and also detected by hydrophone VSP experiment, the hydraulic conductivity was 1.54 x 10{sup -7} cm/sec, while for the same granitic rock at which another single open fracture was found by BTV but not detected by hydrophone VSP experiment, the hydraulic conductivity was less than 6 x 10{sup -10} cm/sec. Second, we converted the hydraulic conductivity of 1.54 x 10{sup -7} cm/sec which was obtained in a hydraulic test section of length 2.5 m into an equivalent value for a single open fracture of width 1 mm. The converted value (3.8 x 10{sup -4} cm/sec) was similar to the hydraulic conductivity estimated from hydrophone VSP experiment. In conclusion, the hydraulic test result shows that hydrophone VSP is useful to estimate an approximate hydraulic conductivity of a single open fracture. (author)

  3. Significance of Shrinkage Induced Clamping Pressure in Fiber-Matrix Bonding in Cementitious Composite Materials

    DEFF Research Database (Denmark)

    Stang, Henrik

    1996-01-01

    The present paper accesses the significance of shrinkage inducedclamping pressure in fiber/matrix bonding mechanisms incementitious composite materials. The paper contains a description of an experimental setup whichallows mbox{measurement} of the clamping pressure which develops on anelastic...... acting on any elastic inhomogeneityembedded in the same cementitious matrix material. Fiber-shaped inhomogeneities are of special interest in cementitious composite material systems andresults are presented for the development of clamping pressure on three typical fiber types in two typical cementpastes...... used in high performance cementitious composite materials.Assuming a Coulomb type of friction on the fiber/matrix interface andusing typical values for the frictional coefficient it is shownthat the shrinkage induced clamping pressure could be one of the mostimportant factors determining the frictional...

  4. Development of planar patch clamp technology and its application in the analysis of cellular electrophysiology

    Institute of Scientific and Technical Information of China (English)

    Peihua Chen; Wei Zhang; Jun Zhou; Ping Wang; Lidan Xiao; Mo Yang

    2009-01-01

    A patch clamp chip, as a novel cell-based chip for electrophysiological recordings, has many prominent advantages such as high res-olution, accuracy, high throughput and automation. It can be used to perform multivariate and real-time measurements of cell networks in situ. Therefore, this technology will dramatically promote the research on ionic channels, neuronal networks and the application of this technology in drug screening. This paper reviews the development of planar patch clamp technology and its applications in detail. The latest progress in the research of taste cells electrophysiology and taste transduction is also presented. Finally, this paper analyzes the methodology of neural chips. Based on the current research of our laboratory, the prospective applications of a patch clamp chip in the research of taste sensation and transduction mechanisms at molecular and cellular levels are discussed.

  5. Flange joint system for SRF cavities utilizing high force spring clamps for low particle generation

    Energy Technology Data Exchange (ETDEWEB)

    None

    2017-09-05

    A flange joint system for SRF cavities. The flange joint system includes a set of high force spring clamps that produce high force on the simple flanges of Superconducting Radio Frequency (SRF) cavities to squeeze conventional metallic seals. The system establishes the required vacuum and RF-tight seal with minimum particle contamination to the inside of the cavity assembly. The spring clamps are designed to stay within their elastic range while being forced open enough to mount over the flange pair. Upon release, the clamps have enough force to plastically deform metallic seal surfaces and continue to a new equilibrium sprung dimension where the flanges remain held against one another with enough preload such that normal handling will not break the seal.

  6. Enhancing endogenous stem cells in the newbornvia delayed umbilical cord clamping

    Institute of Scientific and Technical Information of China (English)

    Christopher Lawton; Sandra Acosta; Nate Watson; Chiara Gonzales-Portillo; hTeo Diamandis; Naoki Tajiri; Yuji Kaneko; Paul R. Sanberg; Cesar V. Borlongan

    2015-01-01

    There is currently no consensus among clinicians and scientists over the appropriate or optimal timing for umbilical cord clamping. However, many clinical studies have suggested that delayed cord clamping is associated with various neonatal beneifts including increased blood volume, reduced need for blood transfusion, increased cerebral oxygenation in pre-term infants, and decreased frequency of iron deifciency anemia in term infants. Human umbilical cord blood con-tains signiifcant amounts of stem and progenitor cells and is currently used in the treatment of several life-threatening diseases. We propose that delayed cord clamping be encouraged as it en-hances blood lfow from the placenta to the neonate, which is accompanied by an increase supply of valuable stem and progenitor cells, as well as may improve blood oxygenation and increase blood volume, altogether reducing the infant’s susceptibility to both neonatal and age-related diseases.

  7. [Focus on placental transfusion for preterm neonates: Delayed cord clamping and/or milking?

    Science.gov (United States)

    Sorin, G; Tosello, B

    2016-11-01

    Anemia of prematurity remains a common complication despite recent advances in perinatal and neonatal medicine. The delayed cord clamping (at least 30seconds as recommended) has several benefits: increased hemoglobin and hematocrit levels at birth, improved initial hemodynamic, decreased incidence of transfusions and intraventricular hemorrhages. When the birth transition is difficult, wait 30seconds before clamping can be impossible. So as not to interfere with the neonatal resuscitation, the "milking" has been proposed as an alternative method to the delayed cord clamping. This is a safe and easy method, which can be done either by an obstetrician or pediatrician with comparable results for the child on his hemodynamic, hematological and neurological status. It still lacks technical information on this method and neurodevelopmental outcomes of these preterm infants. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  8. Enhancing endogenous stem cells in the newborn via delayed umbilical cord clamping

    Directory of Open Access Journals (Sweden)

    Christopher Lawton

    2015-01-01

    Full Text Available There is currently no consensus among clinicians and scientists over the appropriate or optimal timing for umbilical cord clamping. However, many clinical studies have suggested that delayed cord clamping is associated with various neonatal benefits including increased blood volume, reduced need for blood transfusion, increased cerebral oxygenation in pre-term infants, and decreased frequency of iron deficiency anemia in term infants. Human umbilical cord blood contains significant amounts of stem and progenitor cells and is currently used in the treatment of several life-threatening diseases. We propose that delayed cord clamping be encouraged as it enhances blood flow from the placenta to the neonate, which is accompanied by an increase supply of valuable stem and progenitor cells, as well as may improve blood oxygenation and increase blood volume, altogether reducing the infant′s susceptibility to both neonatal and age-related diseases.

  9. Enhancing endogenous stem cells in the newborn via delayed umbilical cord clamping.

    Science.gov (United States)

    Lawton, Christopher; Acosta, Sandra; Watson, Nate; Gonzales-Portillo, Chiara; Diamandis, Theo; Tajiri, Naoki; Kaneko, Yuji; Sanberg, Paul R; Borlongan, Cesar V

    2015-09-01

    There is currently no consensus among clinicians and scientists over the appropriate or optimal timing for umbilical cord clamping. However, many clinical studies have suggested that delayed cord clamping is associated with various neonatal benefits including increased blood volume, reduced need for blood transfusion, increased cerebral oxygenation in pre-term infants, and decreased frequency of iron deficiency anemia in term infants. Human umbilical cord blood contains significant amounts of stem and progenitor cells and is currently used in the treatment of several life-threatening diseases. We propose that delayed cord clamping be encouraged as it enhances blood flow from the placenta to the neonate, which is accompanied by an increase supply of valuable stem and progenitor cells, as well as may improve blood oxygenation and increase blood volume, altogether reducing the infant's susceptibility to both neonatal and age-related diseases.

  10. Sequential dissection of multiple ionic currents in single cardiac myocytes under action potential-clamp.

    Science.gov (United States)

    Banyasz, Tamas; Horvath, Balazs; Jian, Zhong; Izu, Leighton T; Chen-Izu, Ye

    2011-03-01

    The cardiac action potential (AP) is shaped by myriad ionic currents. In this study, we develop an innovative AP-clamp Sequential Dissection technique to enable the recording of multiple ionic currents in the single cell under AP-clamp. This new technique presents a significant step beyond the traditional way of recording only one current in any one cell. The ability to measure many currents in a single cell has revealed two hitherto unknown characteristics of the ionic currents in cardiac cells: coordination of currents within a cell and large variation of currents between cells. Hence, the AP-clamp Sequential Dissection method provides a unique and powerful tool for studying individual cell electrophysiology.

  11. FUNDAMENTAL RESONANCE AND BIFURCATION OF LARGE GENERATOR END WINDING WHEN ITS CLAMPING PLATES ARE LOOSE

    Institute of Scientific and Technical Information of China (English)

    HU Yu-da; QIU Jia-jun; TA Na

    2005-01-01

    Vibration problems of a segment of winding between two clamping plates are studied when the clamping plates, which are used to fix stator end winding, are loose. First,magnetic induction expressions of the winding while the generator was running were given by using separation of variables method. Also, the expressions of the winding electromagnetic force and dry friction force between loosing clamping plates were gotten. Secondly, a mechanical model, which was used to study nonlinear vibration problem of the winding, was set up. Fundamental resonance was analyzed by using multiple scales method, and a resonance equation of amplitude and frequency in steady state was given. Then stability,bifurcation and singularity of the steady solution were studied. Criterions of stability and transition set of the bifurcation equation were obtained. At last, through numerical calculations, resonance curves were obtained. The results are helpful for analysis and protection of generator accidents.

  12. Minimum Normal Force Principle Based Quantitive Optimizationof Clamping Forces for Thin Walled Part

    Institute of Scientific and Technical Information of China (English)

    ZHANG Fa-ping; SUN Hou-fang; SHAHID I.Butt

    2008-01-01

    Based on the stability criteria of workpiece-fixture system, quantitative optimization of clamping forces during precise machining process for thin walled part is studied considering the contact condition between wokpiece and locator, the contact mechanical model is achieved ,which is further been used to calculate the entire passive forces acting on the statically undetermined workpiece by means of the force screw theory as well as minimum norm force principle. Furthermore, a new methodology to optimize clamping forces is put forward, on the criteria of keeping the stability of workpiece during cutting process. By this way, the intensity of clamping forces is decreased dramatically, which will be most beneficial for improving the machining quality of thin-walled parts. Finally, a case study is used to support and validate the proposed model.

  13. Comparison of herniorrhaphy versus clamping of umbilical hernias in horses: a retrospective study of 93 cases (1982-1994).

    OpenAIRE

    1996-01-01

    Many uncomplicated umbilical hernias have been managed successfully in foals by the application of a hernia clamp. Isolated reports of complications following clamp application have led some authors to suggest that it is an unsuitable method of treatment. Little information has been published comparing the complication rates associated with the use of hernia clamps and herniorrhaphy in the treatment of umbilical hernias. The purpose of this retrospective study was to report the characteristic...

  14. [Delayed umbilical cord clamping in preterm infants born before 37 weeks of gestation: A prospective observational study].

    Science.gov (United States)

    Dicky, O; Ehlinger, V; Guyard-Boileau, B; Assouline, C; Arnaud, C; Casper, C

    2017-02-01

    Many international studies have demonstrated that delayed umbilical cord clamping reduces neonatal morbidity. However, in France, delayed umbilical cord clamping is still not performed in many neonatal units. The aims of this study were to evaluate the feasibility of developing a protocol of delayed umbilical cord clamping in the maternity ward of the Toulouse university hospital and to evaluate the impact of this new protocol on neonatal mortality. We conducted a prospective observational study including 123 preterm infants born before 37 weeks of gestation between June 2012 and June 2013 and hospitalized at birth. Delayed cord clamping was performed for at least 30s after birth; otherwise, it was evaluated as early cord clamping. We excluded twin-to-twin transfusion syndrome, congenital abnormalities, alloimmunization, and perinatal asphyxia. We analyzed the reasons why delayed umbilical cord clamping was not performed and then neonatal morbidity in our population. Delayed umbilical cord clamping was performed on 79 infants and 44 infants had early umbilical cord clamping. The two groups had similar baseline characteristics. Preterm infants in the delayed cord-clamping group had a higher level of hemoglobin during the first 24h of life (17.9g/dL versus 16.6g/dL, P=0.005), fewer of them required transfusion (14% versus 35%, P=0.03), and fewer presented late-onset sepsis (8% versus 26%, P=0.02) or bronchopulmonary dysplasia (9% versus 26%, P=0.03). There was no statistically significant increase of hyperbilirubinemia requiring phototherapy. Implanting a new protocol of delayed umbilical cord clamping in our maternity ward proved to be possible without difficulty. The advantages of delayed umbilical cord clamping were observed in this prospective study. Today, delayed cord clamping has become a common practice in our maternity unit. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  15. Modified Blalock clamp: a single-hand autostatic device for pulmonary vessel occlusion during lung cancer resection

    OpenAIRE

    Petrella, Francesco; Solli, Piergiorgio; Borri, Alessandro; Spaggiari, Lorenzo

    2011-01-01

    Vascular clamping during lung cancer resection may be difficult in patients with short vessels or large neoplasms preventing adequate and safe exposure. In addition, the physiological vicinity of some vessels to rigid structures like the bronchi may interfere with ideal clamp positioning even in ordinary procedures. We have modified the original Blalock clamp to facilitate the control of pulmonary vessels and physiologically compress the vessel walls, thereby allowing optimal vascular resecti...

  16. DLC coatings for hydraulic applications

    Institute of Scientific and Technical Information of China (English)

    Luca NOBILI; Luca MAGAGNIN

    2009-01-01

    Replacement of lubricating oils with water or low-viscosity fluids is highly desirable in many industrial fields, on account of the environmental and economical advantages. Low lubricity of water might be insufficient for proper operation of hydraulic components, and diamond-like carbon(DLC) coatings are very attractive as solid lubricant films. A remote-plasma PACVD process was utilized to deposit hydrogenated DLC coatings (a-C:H) on different substrates. Microindentation measurements show that the coating hardness is around 35 GPa. Tribological behavior was evaluated by block-on-ring tests performed in water and water with alumina. The wear rate was calculated after measuring the wear volume by a laser profilemeter. Morphological and compositional analysis of the wear tracks reveal that coating failure may occur by abrasive wear or delamination, depending on the substrate properties. Hard and smooth substrates give the best results and dispersed alumina particles increase the wear rate.

  17. Aircraft Hydraulic Systems Dynamic Analysis

    Science.gov (United States)

    1978-10-01

    4400 PSIG OUTLET PRESSURE ~’f UM5 S1 l .( FIF ~0RV lR 1 .I. AP (c R (V) IFWM) APPROX C ASE !VPý :iI S ReUN N•;MRF.. r p kN i t, isI A! f IN, I:E • ’l...and 1F.GI pump modelo were assumed from data supplied by CECO. 165 _ -- --- - SECTION V HYDRAULIC MOTOR MODEL DEVELOPMENT AND VERIFICATION A fixed...3 70 P.,0 601 ~4 M24.0 3 1p ’, 4 r I 1 1 ISIS 2411 APPENDIX E (CONT.) HSFR TECHNICAL MANUAL (AFAPL-TR-76-43, VOL. IV) 4.15 VANE PU`MP SUBROUTINE 4.15A

  18. Can robots patch-clamp as well as humans? Characterization of a novel sodium channel mutation.

    Science.gov (United States)

    Estacion, M; Choi, J S; Eastman, E M; Lin, Z; Li, Y; Tyrrell, L; Yang, Y; Dib-Hajj, S D; Waxman, S G

    2010-06-01

    Ion channel missense mutations cause disorders of excitability by changing channel biophysical properties. As an increasing number of new naturally occurring mutations have been identified, and the number of other mutations produced by molecular approaches such as in situ mutagenesis has increased, the need for functional analysis by patch-clamp has become rate limiting. Here we compare a patch-clamp robot using planar-chip technology with human patch-clamp in a functional assessment of a previously undescribed Nav1.7 sodium channel mutation, S211P, which causes erythromelalgia. This robotic patch-clamp device can increase throughput (the number of cells analysed per day) by 3- to 10-fold. Both modes of analysis show that the mutation hyperpolarizes activation voltage dependence (8 mV by manual profiling, 11 mV by robotic profiling), alters steady-state fast inactivation so that it requires an additional Boltzmann function for a second fraction of total current (approximately 20% manual, approximately 40% robotic), and enhances slow inactivation (hyperpolarizing shift--15 mV by human,--13 mV robotic). Manual patch-clamping demonstrated slower deactivation and enhanced (approximately 2-fold) ramp response for the mutant channel while robotic recording did not, possibly due to increased temperature and reduced signal-to-noise ratio on the robotic platform. If robotic profiling is used to screen ion channel mutations, we recommend that each measurement or protocol be validated by initial comparison to manual recording. With this caveat, we suggest that, if results are interpreted cautiously, robotic patch-clamp can be used with supervision and subsequent confirmation from human physiologists to facilitate the initial profiling of a variety of electrophysiological parameters of ion channel mutations.

  19. Umbilical blood flow patterns directly after birth before delayed cord clamping.

    Science.gov (United States)

    Boere, I; Roest, A A W; Wallace, E; Ten Harkel, A D J; Haak, M C; Morley, C J; Hooper, S B; te Pas, A B

    2015-03-01

    Delayed umbilical cord clamping (DCC) affects the cardiopulmonary transition and blood volume in neonates immediately after birth. However, little is known of blood flow in the umbilical vessels immediately after birth during DCC. The objective is to describe the duration and patterns of blood flow through the umbilical vessels during DCC. Arterial and venous umbilical blood flow was measured during DCC using Doppler ultrasound in uncomplicated term vaginal deliveries. Immediately after birth, the probe was placed in the middle of the umbilical cord, pattern and duration of flow in vein and arteries were evaluated until cord clamping. Thirty infants were studied. Venous flow: In 10% no flow was present, in 57% flow stopped at 4:34 (3:03-7:31) (median (IQR) min:sec) after birth, before the cord was clamped. In 33%, flow continued until cord clamping at 5:13 (2:56-9:15) min:sec. Initially, venous flow was intermittent, increasing markedly during large breaths or stopping and reversing during crying, but then became continuous. Arterial flow: In 17% no flow was present, in 40% flow stopped at 4:22 (2:29-7:17) min:sec, while cord pulsations were still palpable. In 43% flow continued until the cord was clamped at 5:16 (3:32-10:10) min:sec. Arterial flow was pulsatile, unidirectional towards placenta or bidirectional to/from placenta. In 40% flow became continuous towards placenta later on. During delayed umbilical cord clamping, venous and arterial umbilical flow occurs for longer than previously described. Net placental transfusion is probably the result of several factors of which breathing could play a major role. Umbilical flow is unrelated to cessation of pulsations. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  20. Alternative positions for the baby at birth before clamping the umbilical cord.

    Science.gov (United States)

    Airey, Rebecca J; Farrar, Diane; Duley, Lelia

    2010-10-06

    The third stage of labour is from birth of the baby until delivery of the placenta. Clamping the umbilical cord is one component of active management of the third stage. Deferring cord clamping allows blood flow between the baby and the placenta to continue; net transfer to the baby is called placental transfusion. If the cord is clamped immediately placental transfusion is restricted. Gravity is one of several factors that may influence the volume and duration of placental transfusion at both vaginal and caesarean births. Hence raising or lowering the baby whilst the cord is intact may influence placental transfusion, which in turn may affect outcome for the baby and the woman. To compare the effects of alternative positions for the baby between birth and cord clamping on outcome for the baby, outcome for the mother and on use of health service resources. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (July 2010). Randomised trials comparing alternative positions for the baby at vaginal and caesarean birth, before clamping of the umbilical cord. We independently assessed trial eligibility and quality. When necessary, we contacted study authors for additional information. Thirty-seven studies (7559 mother-infant pairs) were excluded: 33 (7296) because they did not compare alternative positions for the baby before clamping the umbilical cord and four (263) due to quasi-random allocation. No studies met the inclusion criteria. One additional trial is ongoing. No randomised trials have assessed the influence of gravity on placental transfusion. Large, well-designed randomised trials are needed to assess whether gravity influences placental transfusion at vaginal and caesarean births and, if so, whether this affects short-term and long-term outcome for the baby and for the mother.

  1. Design and fabrication of a planar patch-clamp substrate using a silicon-on-insulator wafer

    Science.gov (United States)

    Zhenlong, Zhang; Xiangyang, Liu; Yanli, Mao

    2009-09-01

    The planar patch-clamp technique has been applied to high throughput screening in drug discovery. The key feature of this technique is the fabrication of a planar patch-clamp substrate using appropriate materials. In this study, a planar patch-clamp substrate was designed and fabricated using a silicon-on-insulator (SOI) wafer. The access resistance and capacitance of SOI-based planar patch-clamp substrates are smaller than those of bulk silicon-based planar substrates, which will reduce the distributed RC noise.

  2. Clamping drainage is unnecessary after minimally invasive total knee arthroplasty in patients with tranexamic acid

    Science.gov (United States)

    Wu, Yuangang; Yang, Timin; Zeng, Yi; Li, Canfeng; Shen, Bin; Pei, Fuxing

    2017-01-01

    Abstract Background: Drainage and tranexamic acid (TXA) have been widely used in total knee arthroplasty (TKA). However, it remains unclear whether it is necessary to clamp the drain after minimally invasive TKA (MIS-TKA) when TXA is used. We therefore conducted a randomized controlled trial to compare the effects of clamping versus not clamping drainage following MIS-TKA in patients in whom TXA was used. Methods: From January 2015 to December 2015, 121 patients undergoing unilateral primary MIS-TKA were enrolled and randomly divided into 2 groups. In the clamping group (N = 60), drainage was clamped for the 1st 4 postoperative hours. In the nonclamping group (N = 61), drainage was not clamped. All patients underwent a minimidvastus approach and received 10 mg/kg TXA intravenously before tourniquet deflation. We recorded the total blood loss, drainage volume, and transfusion requirements in the postoperative period. We also measured the hemoglobin (Hb) and hematocrit (Hct) levels on postoperative days 1, 3, and 5. Other factors, including range of motion (ROM), visual analog scale (VAS), and occurrence of wound-related complications, deep vein thrombosis (DVT), and pulmonary embolism (PE) were recorded at the time of discharge and 1 and 6 months postoperatively. No statistically significant differences were found between the 2 groups with regard to age, gender, weight, BMI, preoperative Hb and Hct levels, preoperative ROM, VAS, duration of surgery, anesthesia method, and the American Society of Anesthesiologists classification. Results: The clamping group experienced better drainage volume results than the nonclamping group (P < 0.001). There were no statistically significant differences in TBL and transfusion requirements (P = 0.105 and 0.276, respectively); Hb and Hct levels on postoperative days 1, 3, and 5 were similar between the 2 groups. No significant differences were found for ROM, VAS, DVT, PE, wound-related complications, and hospital

  3. In vivo patch clamp recording technique in the study of neurophysiology

    Institute of Scientific and Technical Information of China (English)

    Lan-Wei CUI; Yu-Rong LI

    2006-01-01

    The patch clamp recording technique in vivois a blind patch clamp recording methods to record the current of the spinal or cereral neurons of anaesthesia ( or awake) animals. This technique can be used to study the synaptic function and plasticity in central nervous system in vivoin order to understand the physiological properties of the ion channels from an integrated point of view. The advantage of this technique have already presented itself in the study of the synaptic transmission and nervous network. Nowadays, in vivo patch whole-cell recording technique in combination with other techniques is becoming a common method in the research fields.

  4. Cerebral oxygenation and processed EEG response to clamping and shunting during carotid endarterectomy under general anesthesia.

    Science.gov (United States)

    Perez, William; Dukatz, Christopher; El-Dalati, Sami; Duncan, James; Abdel-Rasoul, Mahmoud; Springer, Andrew; Go, Michael R; Dzwonczyk, Roger

    2015-12-01

    Clamping and shunting during carotid endarterectomy (CEA) surgery causes changes in cerebral blood flow. The purpose of this study was to assess and compare, side by side, the cerebral oxygenation (rSO2) and processed electroencephalogram (EEG) response bilaterally to carotid artery clamping and shunting in patients undergoing CEA under general anesthesia. With institutional approval and written informed consent, patients undergoing CEA under general anesthesia and routine carotid artery shunting were recorded bilaterally, simultaneously and continuously with an rSO2 and processed EEG monitor. The response of the monitors during carotid artery clamping and shunting were assessed and compared between monitors and bilaterally within each monitor. Sixty-nine patients were included in the study. At clamping the surgical-side and contralateral-side rSO2 dropped significantly below the baseline incision value (-17.6 and -9.4% respectively). After shunting, the contralateral-side rSO2 returned to baseline while the surgical-side rSO2 remained significantly below baseline (-9.0%) until the shunt was removed following surgery. At clamping the surgical-side and contralateral-side processed EEG also dropped below baseline (-19.9 and -20.6% respectively). However, following shunt activation, the processed EEG returned bilaterally to baseline. During the course of this research, we found the rSO2 monitor to be clinically more robust (4.4% failure rate) than the processed EEG monitor (20.0% failure rate). There was no correlation between the rSO2 or processed EEG changes that occurred immediately after clamping and the degree of surgical side stenosis measured pre-operatively. Both rSO2 and processed EEG respond to clamping and shunting during CEA. Cerebral oximetry discriminates between the surgical and contralateral side during surgery. The rSO2 monitor is more reliable in the real-world clinical setting. Future studies should focus on developing algorithms based on these

  5. Discussion on compact mechanism of air-stream and synchro-formed clamp plate impact molding

    Directory of Open Access Journals (Sweden)

    Zhenling WANG

    2004-11-01

    Full Text Available Applying the air impact molding method to mold the complicated pattern with wider opening surface and deeper concave, there always exist vaulted phenomenon and lower compactibility of sand mold over the entrance and the concave regions. Using the air-stream and synchro-formed clamp plate impact molding, however, this problem will be preferably solved. In this paper, the compact mechanism of the new molding method and the effect of some configuration factors, such as the area flowed by compressed air and the highness of the protruding block displacement around the diffluent clamp plate, on the compactibility of sand mold were discussed.

  6. Experience of application of clamp-on cross-correlation flow meter in nuclear industry

    Energy Technology Data Exchange (ETDEWEB)

    Gurevich, Y. [Daystar Technology Inc., Ontario (Canada); Ton, V.; Kotenyov, S.; Zhao, C. [Ontario Power Generation, Ontario (Canada); Sharp, B.; Lopez, A. [Advanced Measurements and Analysis Group Inc., Ontario (Canada)

    2010-07-01

    The cross-correlation clamp-on flow meter, CROSSFLOW, developed and manufactured by AMAG, has been used over the world for over 15 years for flow measurements in various systems in nuclear and fossil power plants. Prior that, OPG has used similar technology in Canadian nuclear power plants since 1980-ies. Two recent examples of the application of the clamp-on cross-correlation technology are presented in this paper. In first example OPG meter was used to verify accuracy of ASME nozzles installed in condensate flow lines. In second example AMAG meter was used to measure Diesel Cooling Water (DCW). (author)

  7. Overview of microseismic monitoring of hydraulic fracturing for unconventional oil and gas plays

    Science.gov (United States)

    Shemeta, J. E.

    2011-12-01

    The exponential growth of unconventional resources for oil and gas production has been driven by the use of horizontal drilling and hydraulic fracturing. These drilling and completion methods increase the contact area of the low permeability and porosity hydrocarbon bearing formations and allow for economic production in what was previously considered uncommercial rock. These new resource plays have sparked an enormous interest in microseismic monitoring of hydraulic fracture treatments. As a hydraulic fracture is pumped, microseismic events are emitted in a volume of rock surrounding the stimulated fracture. The goal of the monitoring is to identify and locate the microseismic events to a high degree of precision and to map the position of the induced hydraulic fracture in time and space. The microseismic events are very small, typically having a moment-magnitude range of -4 to 0. The microseismic data are collected using a variety of seismic array designs and instrumentation, including borehole, shallow borehole, near-surface and surface arrays, using either of three-component clamped 15 Hz borehole sondes to simple vertical 10 Hz geophones for surface monitoring. The collection and processing of these data is currently under rapid technical development. Each monitoring method has technical challenges which include accurate velocity modeling, correct seismic phase identification and signal to noise issues. The microseismic locations are used to guide hydrocarbon exploration and production companies in crucial reservoir development decisions such as the direction to drill the horizontal well bores and the appropriate inter-well spacing between horizontal wells to optimally drain the resource. The fracture mapping is also used to guide fracture and reservoir engineers in designing and calibrating the fluid volumes and types, injection rates and pressures for the hydraulic fracture treatments. The microseismic data can be located and mapped in near real-time during

  8. DESIGN AND CONSTRUCTION OF A HYDRAULIC PISTON

    OpenAIRE

    Santos De La Cruz, Eulogio; Universidad Nacional Mayor de San Marcos; Rojas Lazo, Oswaldo; Universidad Nacional Mayor de San Marcos; Yenque Dedios, Julio; Universidad Nacional Mayor de San Marcos; Lavado Soto, Aurelio; Universidad Nacional Mayor de San Marcos

    2014-01-01

    A hydraulic system project includes the design, materials selection and construction of the hydraulic piston, hydraulic circuit and the joint with the pump and its accesories. This equiment will be driven by the force of moving fluid, whose application is in the devices of machines, tools, printing, perforation, packing and others. El proyecto de un sistema hidráulico, comprende el diseño, selección de materiales y construcción del pistón hidráulico, circuito hidráulico y el ensamble con l...

  9. Bubble visualization in a simulated hydraulic jump

    CERN Document Server

    Witt, Adam; Shen, Lian

    2013-01-01

    This is a fluid dynamics video of two- and three-dimensional computational fluid dynamics simulations carried out at St. Anthony Falls Laboratory. A transient hydraulic jump is simulated using OpenFOAM, an open source numerical solver. A Volume of Fluid numerical method is employed with a realizable k-epsilon turbulence model. The goal of this research is to model the void fraction and bubble size in a transient hydraulic jump. This fluid dynamics video depicts the air entrainment characteristics and bubble behavior within a hydraulic jump of Froude number 4.82.

  10. Hydraulic Fracturing and the Environment

    Science.gov (United States)

    Ayatollahy Tafti, T.; Aminzadeh, F.; Jafarpour, B.; de Barros, F.

    2013-12-01

    In this presentation, we highlight two key environmental concerns of hydraulic fracturing (HF), namely induced seismicity and groundwater contamination (GC). We examine the induced seismicity (IS) associated with different subsurface fluid injection and production (SFIP) operations and the key operational parameters of SFIP impacting it. In addition we review the key potential sources for possible water contamination. Both in the case of IS and GC we propose modeling and data analysis methods to quantify the risk factors to be used for monitoring and risk reduction. SFIP include presents a risk in hydraulic fracturing, waste water injection, enhanced oil recovery as well as geothermal energy operations. Although a recent report (NRC 2012) documents that HF is not responsible for most of the induced seismicities, we primarily focus on HF here. We look into vaious operational parameters such as volume and rate of water injection, the direction of the well versus the natural fracture network, the depth of the target and the local stress field and fault system, as well as other geological features. The latter would determine the potential for triggering tectonic related events by small induced seismicity events. We provide the building blocks for IS risk assessment and monitoring. The system we propose will involve adequate layers of complexity based on mapped seismic attributes as well as results from ANN and probabilistic predictive modeling workflows. This leads to a set of guidelines which further defines 'safe operating conditions' and 'safe operating zones' which will be a valuable reference for future SFIP operations. We also illustrate how HF can lead to groundwater aquifer contamination. The source of aquifer contamination can be the hydrocarbon gas or the chemicals used in the injected liquid in the formation. We explore possible pathways of contamination within and discuss the likelihood of contamination from each source. Many of the chemical compounds used

  11. Construction, Calibration, and Validation of a Simple Patch-Clamp Amplifier for Physiology Education

    Science.gov (United States)

    Rouzrokh, Ali; Ebrahimi, Soltan Ahmed; Mahmoudian, Massoud

    2009-01-01

    A modular patch-clamp amplifier was constructed based on the Strickholm design, which was initially published in 1995. Various parts of the amplifier such as the power supply, input circuit, headstage, feedback circuit, output and nulling circuits were redesigned to use recent software advances and fabricated using the common lithographic printed…

  12. Efficiency of frequency conversion of high power laser and KDP crystal clamping method

    Science.gov (United States)

    Yan, Han; Du, Weifeng; Pei, Guoqing; Qin, Tinghai; Ye, Lang; Xu, Xu

    2017-05-01

    In the high power solid laser driver, the frequency conversion unit is of strict requirement to meet the drive condition of ICF. The performance of large caliber KDP crystal, which is the core of frequency conversion of laser, is a vital aspect affecting the overall technical index of the laser driver. In order to get a higher efficiency of frequency conversion, KDP crystal must keep a better surface condition, which asks for high-quality assemblage and adjustment. The current method used in engineering has insufficient knowledge and recognition on surface deformation control of the crystal. Meanwhile, the method itself is of low efficiency on clamping, and lacks of protection for the crystal. Thus, in this article an investigation of crystal clamping method with lower force was performed, factors affecting the surface of crystal were explored, through both imitation and experiment. The clamping method was redesigned and the frequency conversion efficiency was tested. Meanwhile, with the new method, clamping efficiency increases, the optical performance of crystals improves, and the crystals get better protection.

  13. Five-Level Active-Neutral-Point-Clamped DC/DC Converter

    DEFF Research Database (Denmark)

    Liu, Dong; Deng, Fujin; Chen, Zhe

    Multi-level converters are getting more and more attentions because of their obvious merits such as lower voltage stress and harmonic, smaller size of output filters, and so on. In this paper, a five-level active-neutral-point-clamped (5L-ANPC) dc/dc converter is proposed for power transfer...

  14. Two-Dimensional Fiber Positioning and Clamping Device for Product-Internal Microassembly

    NARCIS (Netherlands)

    Henneken, V.A.; Sassen, W.P.; Van der Vlist, W.; Wien, W.H.A.; Tichem, M.; Sarro, P.M.

    2008-01-01

    In this paper, we present a microelectromechanical systems-based two-degrees-of-freedom positioning device combined with a clamping structure for positioning and constraining an optical fiber. The fiber position can be controlled in the two directions perpendicular to the fiber axis using two specif

  15. A bulldog clamp that was forgotten during a coronary artery bypass operation 8 years ago

    Science.gov (United States)

    Celkan, Mehmet Adnan; Bayatli, Kivanc

    2012-01-01

    Prevention of retained foreign bodies in the pericardial cavity is critical for patient safety. We report a patient with a bulldog clamp that was forgotten during a coronary artery bypass operation 8 years ago, which was detected by chance and removed. PMID:22815324

  16. A Single-Strand Annealing Protein Clamps DNA to Detect and Secure Homology.

    Directory of Open Access Journals (Sweden)

    Marcel Ander

    2015-08-01

    Full Text Available Repair of DNA breaks by single-strand annealing (SSA is a major mechanism for the maintenance of genomic integrity. SSA is promoted by proteins (single-strand-annealing proteins [SSAPs], such as eukaryotic RAD52 and λ phage Redβ. These proteins use a short single-stranded region to find sequence identity and initiate homologous recombination. However, it is unclear how SSAPs detect homology and catalyze annealing. Using single-molecule experiments, we provide evidence that homology is recognized by Redβ monomers that weakly hold single DNA strands together. Once annealing begins, dimerization of Redβ clamps the double-stranded region and nucleates nucleoprotein filament growth. In this manner, DNA clamping ensures and secures a successful detection for DNA sequence homology. The clamp is characterized by a structural change of Redβ and a remarkable stability against force up to 200 pN. Our findings not only present a detailed explanation for SSAP action but also identify the DNA clamp as a very stable, noncovalent, DNA-protein interaction.

  17. Critical clamp loader processing by an essential AAA+ protease in Caulobacter crescentus.

    Science.gov (United States)

    Vass, Robert H; Chien, Peter

    2013-11-01

    Chromosome replication relies on sliding clamps that are loaded by energy-dependent complexes. In Escherichia coli, the ATP-binding clamp loader subunit DnaX exists as both long (τ) and short (γ) forms generated through programmed translational frameshifting, but the need for both forms is unclear. Here, we show that in Caulobacter crescentus, DnaX isoforms are unexpectedly generated through partial proteolysis by the AAA+ protease casein lytic proteinase (Clp) XP. We find that the normally processive ClpXP protease partially degrades DnaX to produce stable fragments upon encountering a glycine-rich region adjacent to a structured domain. Increasing the sequence complexity of this region prevents partial proteolysis and generates a τ-only form of DnaX in vivo that is unable to support viability on its own. Growth is restored when γ is provided in trans, but these strains are more sensitive to DNA damage compared with strains that can generate γ through proteolysis. Our work reveals an unexpected mode of partial processing by the ClpXP protease to generate DnaX isoforms, demonstrates that both τ and γ forms of DnaX are required for Caulobacter viability, and identifies a role for clamp loader diversity in responding to DNA damage. The conservation of distinct DnaX isoforms throughout bacteria despite fundamentally different mechanisms for producing them suggests there may be a conserved need for alternate clamp loader complexes during DNA damaging conditions.

  18. Characterization of a patch-clamp microchannel array towards neuronal networks analysis

    DEFF Research Database (Denmark)

    Alberti, Massimo; Snakenborg, Detlef; Lopacinska, Joanna M.

    2010-01-01

    for simultaneous patch clamping of cultured cells or neurons in the same network. A disposable silicon/silicon dioxide (Si/SiO2) chip with a microhole array was integrated in a microfluidic system for cell handling, perfusion and electrical recording. Fluidic characterization showed that our PC mu CA can work...

  19. The Response Clamp: Functional characterization of neural systems using closed-loop control

    Directory of Open Access Journals (Sweden)

    Avner eWallach

    2013-01-01

    Full Text Available The voltage clamp method, pioneered by Hodgkin, Huxley and Katz, laid the foundations to neurophysiological research. Its core rationale is the use of closed-loop control as a tool for system characterization. A recently introduced method, the response clamp, extends the voltage clamp rationale to the functional, phenomenological level. The method consists of on-line estimation of a response variable of interest (e.g. the probability of response or its latency and a simple feedback control mechanism designed to tightly converge this variable towards a desired trajectory. In the present contribution I offer a perspective on this novel method and its applications in the broader context of system identification and characterization. First, I demonstrate how internal state variables are exposed using the method, and how the use of several controllers may allow for a detailed, multi-variable characterization of the system. Second, I discuss three different categories of applications of the method: (i exploration of intrinsically generated dynamics, (ii exploration of extrinsically generated dynamics and (iii generation of input-output trajectories. The relation of these categories to similar uses in the voltage clamp and other techniques is also discussed. Finally, I discuss the method’s limitations, as well as its possible synthesis with existing complementary approaches.

  20. Early vs delayed clamping of the umbilical cord in full term, preterm and very preterm infants

    DEFF Research Database (Denmark)

    Moller, N.K.; Weber, T.

    2008-01-01

    Randomized studies from 2006 and two meta-analyses published in 2007 agree that clamping of the umbilical cord can be delayed. For the preterm and very preterm infant benefits include less need for blood transfusion and less morbidity, especially for the very preterm male infant. For the term...

  1. Enhanced Buck-Boost Three-Level Neutral-Point-Clamped Inverters

    DEFF Research Database (Denmark)

    Tan, K. K.; Gao, F.; Chiang Loh, Poh

    2009-01-01

    In traditional three-level neutral-point-clamped (NPC) inverters, a major issue is capacitor voltage imbalance, which results in low order harmonics. The compensation of the capacitor voltages often require additional control complexity, which cannot be conveniently implemented. The "alternative ...

  2. Thermal and Efficiency Analysis of Five-Level Multilevel-Clamped Multilevel Converter Considering Grid Codes

    DEFF Research Database (Denmark)

    Ma, Ke; Muñoz-Aguilar, R. S.; Rodriguez, Pedro;

    2014-01-01

    In this paper, a five-level multilevel-clamped multilevel converter (5L- MLC2) topology is analyzed based on a typical grid integration application for renewable energy system. The loss and thermal distributions of the power devices in different switching legs are investigated and illustrated und...

  3. Pulse and Trapezoidal Voltage Clamp Applied To Jurkat Cells: A T- Lymphocyte Cell Line

    Science.gov (United States)

    1993-04-01

    clamp. (Upward deflection represents depolarization). Low frequency oscillations are clearly visible. Such oscillations have been described by Maltsev ...1952. (8) Maltsev , V. A. Oscillating and triggering properties of T cell membrane potential. Imun. Lett. 26:277-282, 1990. 13 (9) Gallin, E. K

  4. Two-Dimensional Fiber Positioning and Clamping Device for Product-Internal Microassembly

    NARCIS (Netherlands)

    Henneken, V.A.; Sassen, W.P.; Van der Vlist, W.; Wien, W.H.A.; Tichem, M.; Sarro, P.M.

    2008-01-01

    In this paper, we present a microelectromechanical systems-based two-degrees-of-freedom positioning device combined with a clamping structure for positioning and constraining an optical fiber. The fiber position can be controlled in the two directions perpendicular to the fiber axis using two specif

  5. Pulse-Width-Modulation of Neutral-Point-Clamped Sparse Matrix Converter

    DEFF Research Database (Denmark)

    Loh, P.C.; Blaabjerg, Frede; Gao, F.

    2007-01-01

    literature. Addressing the afore-described issues, this paper focuses on the operational mode analysis of a three-level sparse matrix converter implemented using a neutral-point-clamped inversion stage, and  the design of a number of PWM and modulation ratio compensation schemes for controlling the converter...

  6. Trans-Z-source and Γ-Z-source neutral-point-clamped inverters

    DEFF Research Database (Denmark)

    Wei, Mo; Loh, Poh Chiang; Blaabjerg, Frede

    2015-01-01

    Z-source neutral-point-clamped (NPC) inverters are earlier proposed for obtaining voltage buck-boost and three-level switching simultaneously. Their performances are, however, constrained by a trade-off between their input-to-output gain and modulation ratio. This trade-off can lead to high...

  7. Delayed cord clamping and haemoglobin levels in infancy : a randomised controlled trial in term babies

    NARCIS (Netherlands)

    van Rheenen, Patrick; de Moor, Lette; Eschbach, Sanne; de Grooth, Hannah; Brabin, Bernard

    Objectives This study was carried out to assess whether delaying umbilical cord clamping is effective in improving the haematological status of term infants living in a malaria-endemic area, and whether this is associated with complications in infants and mothers. Metyhods We randomly assigned women

  8. Delayed umbilical cord clamping for reducing anaemia in low birthweight infants : implications for developing countries

    NARCIS (Netherlands)

    van Rheenen, Patrick F.; Gruschke, Sebastian; Brabin, Bernard J.

    BACKGROUND: Cheap and effective interventions are needed to reduce the risk of infant anaemia in developing countries. Delayed cord clamping (DCC) has been shown to be a simple, safe and cost-free delivery procedure that augments red cell mass in appropriate-for-gestational-age term and preterm

  9. Delayed cord clamping in South African neonates with expected low birthweight : a randomised controlled trial

    NARCIS (Netherlands)

    Tiemersma, Sybrich; Heistein, Julia; Ruijne, Roos; Lopez, Gustavo; van Lobenstein, Jeroen; van Rheenen, Patrick

    OBJECTIVE: To evaluate safety and haematological effects of delayed cord clamping (DCC) in infants with expected low birthweight born in a resource-poor setting. METHODS: Randomised controlled trial involving pregnant women in early labour ≥18 years with intrapartum symphysal-fundal height ≤32 cm.

  10. Early umbilical cord clamping contributes to elevated blood lead levels among infants with higher lead exposure.

    Science.gov (United States)

    Chaparro, Camila M; Fornes, Raymond; Neufeld, Lynnette M; Tena Alavez, Gilberto; Eguía-Líz Cedillo, Raúl; Dewey, Kathryn G

    2007-11-01

    To investigate whether infant iron status, modified by umbilical cord clamping time and infant feeding mode, affected infant blood lead concentration at 6 months of age. Participants were a subset of women and their infants randomized to receive early (10 seconds) or delayed (2 minutes) umbilical cord clamping and were monitored to 6 months postpartum in Mexico City. Iron and lead status was analyzed in maternal, placental, and 6-month infant blood samples. Baseline maternal lead exposure data and infant feeding data at 2, 4, and 6 months were collected. In the total sample, maternal blood lead concentration, infant ferritin, and breast-feeding practices predicted infant blood lead concentration. Among infants with higher placental blood lead concentration and breast-fed infants not receiving any iron-fortified formula or milk at 6 months, early clamping increased infant blood lead concentration, an effect mediated in part via decreased infant iron status. Early cord clamping, by decreasing infant iron status, contributes to higher blood lead concentrations at 6 months of age among infants at high risk.

  11. A New Preparation of Pancreatic Ducts for Patch-Clamp Studies

    DEFF Research Database (Denmark)

    Novak, Ivana; Hug, M.J.

    1995-01-01

    parameters, monitored with the whole-cell patch-clamp method, and those in isolated perfused ducts, monitored with the conventional microelectrodes [Novak I, Greger R: Pflügers Arch 1988;411:58-68, 546-553], are comparable. Similar conclusion can be made about the calcium measurements [Hug M, et al: Pflügers...

  12. A direct proofreader-clamp interaction stabilizes the Pol III replicase in the polymerization mode

    NARCIS (Netherlands)

    Jergic, Slobodan; Horan, Nicholas P.; Elshenawy, Mohamed M.; Mason, Claire E.; Urathamakul, Thitima; Ozawa, Kiyoshi; Robinson, Andrew; Goudsmits, Joris M. H.; Wang, Yao; Pan, Xuefeng; Beck, Jennifer L.; van Oijen, Antoine M.; Huber, Thomas; Hamdan, Samir M.; Dixon, Nicholas E.

    2013-01-01

    Processive DNA synthesis by the alpha epsilon theta core of the Escherichia coli Pol III replicase requires it to be bound to the beta(2) clamp via a site in the a polymerase subunit. How the epsilon proofreading exonuclease subunit influences DNA synthesis by alpha was not previously understood. In

  13. Glucose consumption by various tissues in pregnant rats : effects of a 6-day euglycaemic hyperinsulinaemic clamp

    NARCIS (Netherlands)

    Nieuwenhuizen, AG; Schuiling, GA; Bonen, A; Paans, AMJ; Vaalburg, W; Koiter, TR

    1998-01-01

    In the course of pregnancy maternal tissues become increasingly more insensitive to insulin. As 6 days of euglycaemic hyperinsulinaemic clamping, from day 8 until 14 of gestation, ameliorates total glucose consumption, we analysed the contribution of individual tissues in this phenomenon. We measure

  14. Experimental and numerical analysis of clamped joints in front motorbike suspensions

    Directory of Open Access Journals (Sweden)

    Vincenzi N.

    2010-06-01

    Full Text Available Clamped joints are shaft-hub connections used, as an instance, in front motorbike suspensions to lock the steering plates with the legs and the legs with the wheel pin, by means of one or two bolts. The preloading force, produced during the tightening process, should be evaluated accurately, since it must lock safely the shaft, without overcoming the yielding point of the hub. Firstly, friction coefficients have been evaluated on “ad-hoc designed” specimens, by applying the Design of Experiment approach: the applied tightening torque has been precisely related to the imposed preloading force. Then, the tensile state of clamps have been evaluated both via FEM and by leveraging some design formulae proposed by the Authors as function of the preloading force and of the clamp geometry. Finally, the results have been compared to those given by some strain gauges applied on the tested clamps: the discrepancies between numerical analyses, the design formulae and the experimental results remains under a threshold of 10%.

  15. A bulldog clamp that was forgotten during a coronary artery bypass operation 8 years ago.

    Science.gov (United States)

    Celkan, Mehmet Adnan; Bayatli, Kivanc

    2012-10-01

    Prevention of retained foreign bodies in the pericardial cavity is critical for patient safety. We report a patient with a bulldog clamp that was forgotten during a coronary artery bypass operation 8 years ago, which was detected by chance and removed.

  16. Calcium Release in Frog Cut Twitch Fibers Exposed to Different Ionic Environments under Voltage Clamp

    National Research Council Canada - National Science Library

    Hui, Chiu Shuen

    1999-01-01

    Calcium release was measured in highly stretched frog cut twitch fibers mounted in a double Vaseline-gap voltage clamp chamber, with the internal solution containing 20 mM EGTA plus 0.4 or 1.8 mM added calcium...

  17. Study on Characteristics of Hydraulic Servo System for Force Control of Hydraulic Robots

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyo-gon; Han, Changsoo [Hanyang University, Seoul (Korea, Republic of); Lee, Jong-won [Korea University of Science and Technology, Seoul (Korea, Republic of); Park, Sangdeok [Korea Institute of Industrial Technology, Seoul (Korea, Republic of)

    2015-02-15

    Because a hydraulic actuator has high power and force densities, this allows the weight of the robot's limbs to be reduced. This allows for good dynamic characteristics and high energy efficiency. Thus, hydraulic actuators are used in some exoskeleton robots and quadrupedal robots that require high torque. Force control is useful for robot compliance with a user or environment. However, force control of a hydraulic robot is difficult because a hydraulic servo system is highly nonlinear from a control perspective. In this study, a nonlinear model was used to develop a simulation program for a hydraulic servo system consisting of a servo valve, transmission lines, and a cylinder. The problems and considerations with regard to the force control performance for a hydraulic servo system were investigated. A force control method using the nonlinear model was proposed, and its effect was evaluated with the simulation program.

  18. Parker Hybrid Hydraulic Drivetrain Demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Collett, Raymond [Parker-Hannifin Corporation, Cleveland, OH (United States); Howland, James [Parker-Hannifin Corporation, Cleveland, OH (United States); Venkiteswaran, Prasad [National Energy Technology Lab. (NETL), Morgantown, WV (United States)

    2014-03-31

    This report examines the benefits of Parker Hannifin hydraulic hybrid brake energy recovery systems used in commercial applications for vocational purposes. A detailed background on the problem statement being addressed as well as the solution set specific for parcel delivery will be provided. Objectives of the demonstration performed in high start & stop applications included opportunities in fuel usage reduction, emissions reduction, vehicle productivity, and vehicle maintenance. Completed findings during the demonstration period and parallel investigations with NREL, CALSTART, along with a literature review will be provided herein on this research area. Lastly, results identified in the study by third parties validated the savings potential in fuel reduction of on average of 19% to 52% over the baseline in terms of mpg (Lammert, 2014, p11), Parker data for parcel delivery vehicles in the field parallels this at a range of 35% - 50%, emissions reduction of 17.4% lower CO2 per mile and 30.4% lower NOx per mile (Gallo, 2014, p15), with maintenance improvement in the areas of brake and starter replacement, while leaving room for further study in the area of productivity in terms of specific metrics that can be applied and studied.

  19. Thermal hydraulics development for CASL

    Energy Technology Data Exchange (ETDEWEB)

    Lowrie, Robert B [Los Alamos National Laboratory

    2010-12-07

    This talk will describe the technical direction of the Thermal-Hydraulics (T-H) Project within the Consortium for Advanced Simulation of Light Water Reactors (CASL) Department of Energy Innovation Hub. CASL is focused on developing a 'virtual reactor', that will simulate the physical processes that occur within a light-water reactor. These simulations will address several challenge problems, defined by laboratory, university, and industrial partners that make up CASL. CASL's T-H efforts are encompassed in two sub-projects: (1) Computational Fluid Dynamics (CFD), (2) Interface Treatment Methods (ITM). The CFD subproject will develop non-proprietary, scalable, verified and validated macroscale CFD simulation tools. These tools typically require closures for their turbulence and boiling models, which will be provided by the ITM sub-project, via experiments and microscale (such as DNS) simulation results. The near-term milestones and longer term plans of these two sub-projects will be discussed.

  20. MATLAB implementation of a dynamic clamp with bandwidth >125 KHz capable of generating INa at 37°C

    Science.gov (United States)

    Clausen, Chris; Valiunas, Virginijus; Brink, Peter R.; Cohen, Ira S.

    2012-01-01

    We describe the construction of a dynamic clamp with bandwidth >125 KHz that utilizes a high performance, yet low cost, standard home/office PC interfaced with a high-speed (16 bit) data acquisition module. High bandwidth is achieved by exploiting recently available software advances (code-generation technology, optimized real-time kernel). Dynamic-clamp programs are constructed using Simulink, a visual programming language. Blocks for computation of membrane currents are written in the high-level matlab language; no programming in C is required. The instrument can be used in single- or dual-cell configurations, with the capability to modify programs while experiments are in progress. We describe an algorithm for computing the fast transient Na+ current (INa) in real time, and test its accuracy and stability using rate constants appropriate for 37°C. We then construct a program capable of supplying three currents to a cell preparation: INa, the hyperpolarizing-activated inward pacemaker current (If), and an inward-rectifier K+ current (IK1). The program corrects for the IR drop due to electrode current flow, and also records all voltages and currents. We tested this program on dual patch-clamped HEK293 cells where the dynamic clamp controls a current-clamp amplifier and a voltage-clamp amplifier controls membrane potential, and current-clamped HEK293 cells where the dynamic clamp produces spontaneous pacing behavior exhibiting Na+ spikes in otherwise passive cells. PMID:23224681

  1. Evaluation of diel patterns of relative changes in cell turgor of tomato plants using leaf patch clamp pressure probes

    NARCIS (Netherlands)

    Lee, K.M.; Driever, S.M.; Heuvelink, E.; Rüger, S.; Zimmermann, U.; Gelder, de A.; Marcelis, L.F.M.

    2012-01-01

    Relative changes in cell turgor of leaves of well-watered tomato plants were evaluated using the leaf patch clamp pressure probe (LPCP) under dynamic greenhouse climate conditions. Leaf patch clamp pressure changes, a measure for relative changes in cell turgor, were monitored at three different hei

  2. Transputer Control of Hydraulic Actuators and Robots

    DEFF Research Database (Denmark)

    Conrad, Finn

    1996-01-01

    Results from a Danish mechatronics research program entitled IMCIA - Intelligent Control and Intelligent Actuators. The objective is development of intelligent actuators for intelligent motion control. A mechatronics test facility with a transputer controlled hydraulic robot suiteable for real...

  3. Concept Evaluation for Hydraulic Yaw System

    DEFF Research Database (Denmark)

    Stubkier, Søren; Pedersen, Henrik C.; Andersen, Torben Ole

    2013-01-01

    a suspension system on a car, leading the loads away from the turbine structure. However, to realize a soft hydraulic yaw system a new design concept must be found. As a part of the development of the new concept a preliminary concept evaluation has been conducted, evaluating seven different hydraulic yaw...... concepts, ranging from a one-to-one copy of the electrical drive (electrical drives replaced by hydraulic dittos), to floating suspension systems mounted on hydraulic cylinders. Rough calculations of size and consequences of the different systems are presented ending up with the final concept for further...... investigation. Loads and yaw demands are based on the IEC 61400-1 standard for wind turbine design, and the loads for this examination are extrapolated from the HAWC2 aeroelastic design code. The concepts are based on a 5 MW off-shore turbine....

  4. HYDRAULICS, Des Moines COUNTY, IOWA, USA

    Data.gov (United States)

    Federal Emergency Management Agency, Department of Homeland Security — Hydraulic data include spatial datasets and data tables necessary for documenting the hydrologic procedures for estimating flood discharges for a flood insurance...

  5. ON THE THEORIES OF HYDRAULIC GEOMETRY

    Institute of Scientific and Technical Information of China (English)

    Vijay P. SINGH

    2003-01-01

    Hydraulic geometry is of fundamental importance in planning, design, and management of river engineering and training works. Although some concepts of hydraulic geometry were proposed toward the end of the nineteenth century, the real impetus toward formulating a theory of hydraulic geometry was provided by the work of Leopold and Maddock (1953). A number of theories have since been proposed.Some of the theories are interrelated but others are based on quite different principles. All theories,however, assume that the river flow is steady and uniform and the river tends to attain a state of equilibrium or quasi-equilibrium. The differences are due to the differences in hydraulic mechanisms that the theories employ to explain the attainment of equilibrium by the river.

  6. Stream restoration hydraulic design course: lecture notes

    National Research Council Canada - National Science Library

    Newbury, R

    2002-01-01

    Steam restoration encompasses a broad range of activities and disciplines. This lecture series is designed for practitioners who must fit habitat improvement works in the hydraulics of degraded channels...

  7. Drawing a pictogram operator - hydraulic stowing assembly

    Energy Technology Data Exchange (ETDEWEB)

    Bukhgol' ts, V.P.; Dinershtein, V.A.

    1984-11-01

    Hydraulic stowing is widely used during the extraction of coal from seams prone to spontaneous ignition or from seams situated under preserved structures. Experience has shown that the presence of a considerable number of controlling and measuring devices on hydraulic stowing assemblies results in erratic operations. The authors, after examining the controls of the hydraulic stowing complexes, recommend that all functions which the operator might perform badly or not at all should be controlled automatically. The operator must, however, have access to manual controls which should be included in the system in order to achieve an effective and trouble free operation. The authors propose a pictogram to explain the relationship between the human operator and the hydraulic complex, based on structural diagrams. The system developed, which was tried out at the Koksovaya mine, increased the efficiency of the complex and reduced the work load of the operator. 3 references.

  8. HYDRAULICS, Des Moines COUNTY, IOWA, USA

    Data.gov (United States)

    Federal Emergency Management Agency, Department of Homeland Security — Hydraulic data include spatial datasets and data tables necessary for documenting the hydrologic procedures for estimating flood discharges for a flood insurance...

  9. Hydraulic fracturing chemicals and fluids technology

    CERN Document Server

    Fink, Johannes

    2013-01-01

    When classifying fracturing fluids and their additives, it is important that production, operation, and completion engineers understand which chemical should be utilized in different well environments. A user's guide to the many chemicals and chemical additives used in hydraulic fracturing operations, Hydraulic Fracturing Chemicals and Fluids Technology provides an easy-to-use manual to create fluid formulations that will meet project-specific needs while protecting the environment and the life of the well. Fink creates a concise and comprehensive reference that enables the engineer to logically select and use the appropriate chemicals on any hydraulic fracturing job. The first book devoted entirely to hydraulic fracturing chemicals, Fink eliminates the guesswork so the engineer can select the best chemicals needed on the job while providing the best protection for the well, workers and environment. Pinpoints the specific compounds used in any given fracturing operation Provides a systematic approach to class...

  10. Transputer Control of Hydraulic Actuators and Robots

    DEFF Research Database (Denmark)

    Conrad, Finn

    1996-01-01

    Results from a Danish mechatronics research program entitled IMCIA - Intelligent Control and Intelligent Actuators. The objective is development of intelligent actuators for intelligent motion control. A mechatronics test facility with a transputer controlled hydraulic robot suiteable for real...

  11. An AFM-based stiffness clamp for dynamic control of rigidity.

    Directory of Open Access Journals (Sweden)

    Kevin D Webster

    Full Text Available Atomic force microscopy (AFM has become a powerful tool for measuring material properties in biology and imposing mechanical boundary conditions on samples from single molecules to cells and tissues. Constant force or constant height can be maintained in an AFM experiment through feedback control of cantilever deflection, known respectively as a 'force clamp' or 'position clamp'. However, stiffness, the third variable in the Hookean relation F = kx that describes AFM cantilever deflection, has not been dynamically controllable in the same way. Here we present and demonstrate a 'stiffness clamp' that can vary the apparent stiffness of an AFM cantilever. This method, employable on any AFM system by modifying feedback control of the cantilever, allows rapid and reversible tuning of the stiffness exposed to the sample in a way that can decouple the role of stiffness from force and deformation. We demonstrated the AFM stiffness clamp on two different samples: a contracting fibroblast cell and an expanding polyacrylamide hydrogel. We found that the fibroblast, a cell type that secretes and organizes the extracellular matrix, exhibited a rapid, sub-second change in traction rate (dF/dt and contraction velocity (dx/dt in response to step changes in stiffness between 1-100 nN/µm. This response was independent of the absolute contractile force and cell height, demonstrating that cells can react directly to changes in stiffness alone. In contrast, the hydrogel used in our experiment maintained a constant expansion velocity (dx/dt over this range of stiffness, while the traction rate (dF/dt changed with stiffness, showing that passive materials can also behave differently in different stiffness environments. The AFM stiffness clamp presented here, which is applicable to mechanical measurements on both biological and non-biological samples, may be used to investigate cellular mechanotransduction under a wide range of controlled mechanical boundary

  12. Influence of phenylephrine or ephedrine on maternal hemodynamics upon umbilical cord clamping during cesarean delivery.

    Science.gov (United States)

    Quan, Zhefeng; Tian, Ming; Chi, Ping; Cao, Yinghao; Li, Xin; Peng, Kejun

    2013-11-01

    Vasopressors ephedrine and phenylephrine are commonly used with spinal anesthesia during cesarean delivery. Studies on them have focused on the period before the umbilical cord is clamped, although anesthesia is continuously administered throughout and after this event. This study aimed to compare the effects of these drugs on maternal hemodynamics at and after clamping of the umbilical cord. Prospective, randomized, double-blind study. Parturients (n = 60) scheduled for elective cesarean delivery were randomly divided into an ephedrine group and a phenylephrine group. Each woman received an intrathecal injection of bupivacaine (7.5 mg). Patients in the ephedrine and phenylephrine groups were infused continuously with ephedrine (0.02 mg×kg-1×min-1) or phenylephrine (0.25 μg×kg-1×min-1), respectively, from immediately after the injection of bupivacaine until termination 10 minutes after the umbilical cord was clamped (the endpoint). Hemodynamic changes were recorded. After clamping the umbilical cord, the patients who were administered ephedrine experienced significant increases in heart rate (89 ± 11 beats/min to 106 ± 15 beats/min), cardiac output (6.4 ± 0.9 l/min to 7.6 ± 1.2 l/min) and cardiac index (3.5 ± 0.39 l×min-1×m-2 to 4.3 ± 0.48 l×min-1×m-2), while the systemic vascular resistance decreased (908 ± 296 dyne·s/cm5 to 711 ± 285 dyne·s/cm5). Such differences were not observed in the patients who received phenylephrine. Moreover, the heart rate of patients administered ephedrine was higher than that of patients given phenylephrine after clamping the umbilical cord. Continuous infusion of phenylephrine during cesarean delivery maintains a stable maternal hemodynamic status better than ephedrine.

  13. A physiological approach to the timing of umbilical cord clamping at birth.

    Science.gov (United States)

    Hooper, Stuart B; Polglase, Graeme R; te Pas, Arjan B

    2015-07-01

    Umbilical cord clamping at birth has a major impact on an infant's cardiovascular system that varies in significance depending upon whether the infant has commenced breathing. As umbilical venous return is a major source of preload for the left ventricle during fetal life, recent experimental evidence has shown that clamping the umbilical cord severely limits cardiac venous return in the absence of pulmonary ventilation. As a result, cardiac output greatly reduces and remains low until breathing commences. Once the infant begins breathing, aeration of the lung triggers a large increase in pulmonary blood flow, which replaces umbilical venous return as the source of preload for the left ventricle. As a result, cardiac output markedly increases, as indicated by an increase in heart rate immediately after birth. Thus, infants born apnoeic and hypoxic and have their cords immediately clamped, are likely to have a restricted cardiac output combined with hypoxia. As increased cardiac output is a major physiological defence mechanism that counteracts the effects of hypoxaemia, limiting the increase in cardiac output exposes the infant to ischaemia along with hypoxia. However, if the infant commences breathing, aerates its lungs and increases pulmonary blood flow before the umbilical cord is clamped, then pulmonary venous return can immediately take over the supply of left ventricular preload upon cord clamping. As a result, there is no intervening period of reduced preload and cardiac output and the large swings in arterial pressures and flows are reduced leading to a more stable circulatory transition. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  14. Ventilation before Umbilical Cord Clamping Improves the Physiological Transition at Birth.

    Science.gov (United States)

    Bhatt, Sasmira; Polglase, Graeme R; Wallace, Euan M; Te Pas, Arjan B; Hooper, Stuart B

    2014-01-01

    The transition from a fetus to a neonate at birth represents a critical phase in our life. Most infants make this transition without complications, but preterm infants usually require some form of assistance due to immature cardiopulmonary systems that predispose them to lifelong sequelae. As the incidence of preterm birth is increasing, there is now an urgent need for the development of management strategies that facilitate this transition, which will likely include improved strategies for the management of the maternal third stage of labor. For instance, recent studies on the physiological transition at birth have led to the discovery that establishing ventilation in the infant before the umbilical cord is clamped greatly stabilizes the cardiovascular transition at birth. While most benefits of delayed clamping previously have been attributed to an increase in placenta to infant blood transfusion, clearly there are other significant benefits for the infant, which are not well understood. Nevertheless, if ventilation can be established before cord clamping in a preterm infant, the large adverse changes in cardiac function that normally accompanies umbilical cord clamping can be avoided. As preterm infants have an immature cerebral vascular bed, large swings in cardiovascular function places them at high risk of cerebral vascular rupture and the associated increased risk of mortality and morbidity. In view of the impact that cord clamping has on the cardiovascular transition at birth, it is also time to re-examine some of the strategies used in the management of the third stage of labor. These include the appropriate timing of uterotonic administration in relation to delivery of the infant and placenta. As there is a lack of evidence on the effects these individual practices have on the infant, there is a necessity to improve our understanding of their impact in order to develop strategies that facilitate the transition to newborn life.

  15. An AFM-based stiffness clamp for dynamic control of rigidity.

    Science.gov (United States)

    Webster, Kevin D; Crow, Ailey; Fletcher, Daniel A

    2011-03-08

    Atomic force microscopy (AFM) has become a powerful tool for measuring material properties in biology and imposing mechanical boundary conditions on samples from single molecules to cells and tissues. Constant force or constant height can be maintained in an AFM experiment through feedback control of cantilever deflection, known respectively as a 'force clamp' or 'position clamp'. However, stiffness, the third variable in the Hookean relation F = kx that describes AFM cantilever deflection, has not been dynamically controllable in the same way. Here we present and demonstrate a 'stiffness clamp' that can vary the apparent stiffness of an AFM cantilever. This method, employable on any AFM system by modifying feedback control of the cantilever, allows rapid and reversible tuning of the stiffness exposed to the sample in a way that can decouple the role of stiffness from force and deformation. We demonstrated the AFM stiffness clamp on two different samples: a contracting fibroblast cell and an expanding polyacrylamide hydrogel. We found that the fibroblast, a cell type that secretes and organizes the extracellular matrix, exhibited a rapid, sub-second change in traction rate (dF/dt) and contraction velocity (dx/dt) in response to step changes in stiffness between 1-100 nN/µm. This response was independent of the absolute contractile force and cell height, demonstrating that cells can react directly to changes in stiffness alone. In contrast, the hydrogel used in our experiment maintained a constant expansion velocity (dx/dt) over this range of stiffness, while the traction rate (dF/dt) changed with stiffness, showing that passive materials can also behave differently in different stiffness environments. The AFM stiffness clamp presented here, which is applicable to mechanical measurements on both biological and non-biological samples, may be used to investigate cellular mechanotransduction under a wide range of controlled mechanical boundary conditions.

  16. Ventilation before Umbilical Cord Clamping improves the physiological transition at birth.

    Directory of Open Access Journals (Sweden)

    Sasmira eBhatt

    2014-10-01

    Full Text Available The transition from a fetus to a neonate at birth represents a critical phase in our life. Most infants make this transition without complications, but preterm infants usually require some form of assistance due to immature cardiopulmonary systems that predispose them to lifelong sequelae. As the incidence of preterm birth is increasing, there is now an urgent need for the development of management strategies that facilitate this transition, which will likely include improved strategies for the management of the maternal third stage of labour. For instance, recent studies on the physiological transition at birth have led to the discovery that establishing ventilation in the infant before the umbilical cord is clamped greatly stabilizes the cardiovascular transition at birth. While most benefits of delayed clamping have previously been attributed to an increase in placenta to infant blood transfusion, clearly there are other significant benefits for the infant, which are not well understood. Nevertheless, if ventilation can be established before cord clamping in a preterm infant, the large adverse changes in cardiac function that normally accompanies umbilical cord clamping can be avoided. As preterm infants have an immature cerebral vascular bed, large swings in cardiovascular function places them at high risk of cerebral vascular rupture and the associated increased risk of mortality and morbidity. In view of the impact that cord clamping has on the cardiovascular transition at birth, it is also time to re-examine some of the strategies used in the management of the third stage of labour. These include the appropriate timing of uterotonic administration in relation to delivery of the infant and placenta. As there is a lack of evidence on the effects these individual practices have on the infant, there is a necessity to improve our understanding of their impact in order to develop strategies that facilitate the transition to newborn life.

  17. 46 CFR 112.50-3 - Hydraulic starting.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Hydraulic starting. 112.50-3 Section 112.50-3 Shipping... POWER SYSTEMS Emergency Diesel and Gas Turbine Engine Driven Generator Sets § 112.50-3 Hydraulic starting. A hydraulic starting system must meet the following: (a) The hydraulic starting system must be...

  18. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  19. RESEARCH OF THE DYNAMIC CHARACTERISTICS ON A NEW HYDRAULIC SYSTEM OF ELECTRO-HYDRAULIC HAMMER

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    A new typed hydraulic system of electro-hydraulic hammer is researched and developed.By means of power bond graphs the modeling and simulation to the dynamic characteristics of the new hydraulic system are performed. The experimental research which is emphasized on the blowing stroke is also performed. It is proved from the result of simulation and experiment that this new hydraulic system possesses such advantages as simplification of structure,flexibleness of operation and reliability of working. Especially it possesses better dynamic characteristics.

  20. Design of a laboratory hydraulic device for testing of hydraulic pumps

    Directory of Open Access Journals (Sweden)

    Pavel Máchal

    2013-01-01

    Full Text Available The present contribution deals with solves problem of research of testing device to monitor of hydrostatic pumps durability about dynamic loading under laboratory conditions. When carrying out the design of testing device are based on load characteristics of tractor hydraulic circuit, the individual characteristics of hydraulic components and performed calculations. Load characteristics on the tractors CASE IH Magnum 310, JOHN DEERE 8100, ZETOR FORTERRA 114 41 and Fendt 926 Vario were measured. Design of a hydraulic laboratory device is based on the need for testing new types of hydraulic pumps or various types of hydraulic fluids. When creating of hydraulic device we focused on testing hydraulic pumps used in agricultural and forestry tractors. Proportional pressure control valve is an active member of the hydraulic device, which provides change of a continuous control signal into relative pressure of operating fluid. The advantage of a designed hydraulic system is possibility of simulation of dynamic operating loading, which is obtained by measurement under real conditions, and thereby creates laboratory conditions as close to real conditions as possible. The laboratory device is constructed at the Department of Transport and Handling, Faculty of Engineering, Slovak University of Agriculture in Nitra.

  1. Characterization of a hydraulically induced bedrock fracture

    OpenAIRE

    2014-01-01

    Hydraulic fracturing is a controversial practice because of concerns about environmental impacts due to its widespread use in recovering unconventional petroleum and natural gas deposits. However, water-only hydraulic fracturing has been used safely and successfully for many years to increase the permeability of aquifers used for drinking and irrigation water supply. This process extends and widens existing bedrock fractures, allowing groundwater storage to increase. Researchers have studied ...

  2. FEEDBACK LINEARISATION APPLIED ON A HYDRAULIC

    DEFF Research Database (Denmark)

    Andersen, Torben Ole; Hansen, Michael Rygaard; Pedersen, Henrik C.;

    2005-01-01

    Generally most hydraulic systems are intrensically non-linear, why applying linear control techniques typically results in conservatively dimensioned controllers to obtain stable performance. Non-linear control techniques have the potential of overcoming these problems, and in this paper the focus...... is on developing and applying several different feedback linearisation (FL) controllers to the individual servo actuators in a hydraulically driven servo robot to evaluate and compare their possiblities and limitations. This is done based on both simulation and experimental results....

  3. Data Analytics of Hydraulic Fracturing Data

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jovan Yang [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Viswanathan, Hari [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hyman, Jeffery [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Middleton, Richard [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-08-11

    These are a set of slides on the data analytics of hydraulic fracturing data. The conclusions from this research are the following: they proposed a permeability evolution as a new mechanism to explain hydraulic fracturing trends; they created a model to include this mechanism and it showed promising results; the paper from this research is ready for submission; they devised a way to identify and sort refractures in order to study their effects, and this paper is currently being written.

  4. Hydraulic Motor Driving Variable-Pitch System for Wind Turbine

    Directory of Open Access Journals (Sweden)

    Ye HUANG

    2013-11-01

    Full Text Available The present hydraulic variable-pitch mechanism of wind turbine uses three hydraulic cylinders to drive three crank and connecting rod mechanisms respectively; the blades are moved with the cranks. The hydraulic variable-pitch mechanism has complex structure, occupies a lot of space and its maintenance is trouble. In order to make up for the shortcomings of hydraulic cylinder variable-pitch system, the present hydraulic variable-pitch mechanism should be changed as follows: hydraulic motors are used to drive gears; gears drive blades; the electro-hydraulic proportional valves are used to control hydraulic motors. The hydraulic control part and electrical control part of variable-pitch system is redesigned. The new variable-pitch system is called hydraulic motor driving variable-pitch system. The new variable-pitch system meets the control requirements of blade pitch, makes the structure simple and its application effect is perfect.    

  5. Behaviour of lab parameters and neonatal weight loss in relation to neonatal breathing movements and cord clamping time.

    Science.gov (United States)

    Indraccolo, U; Santafata, R; Palazzetti, P L; Di Iorio, R; Indraccolo, S R

    2013-01-01

    To date, delaying cord clamping two to three minutes after birth is considered effective for newborn well-being. This time does not consider the newborn's breathing movements, which may also condition neonate well-being. To investigate the behaviour of neonatal weight loss and of some umbilical vein lab parameters, in relation to timing of newborn breathing and cord clamping. Time from birth to cord clamping and time from birth to first cry of the newborn were collected in 87 full-term healthy women. First cry is a sign of effective breathing. Birth weight loss at the first, second, and third day from birth and lab parameters were assessed in relation to: time from birth to cord clamping, time from birth to first cry, and cord clamping before or after the first cry. Partial pressure of carbon dioxide (pCO2) decreased if cord clamping was performed after first cry and increased if first cry occurred after cord clamping, independently from the time elapsed from birth to first cry (p = 0.012). Calcium (Ca(2+)) concentration decreased if cord clamping was performed after the first cry and increased if first cry of the baby after birth was delayed (p = 0.021). Each second of delay from birth to cord clamping resulted in an increase in Cl- concentration (p cord clamping resulted in a reduction in the percentage of weight loss at the first day (p = 0.024), at the second day (p = 0.007), and at the third day (p = 0.028) after birth. Neonate breathing after birth should induce umbilical vein flow from placenta to lungs, conditioning the reduction of birth weight loss after birth and umbilical lab parameters modifications.

  6. An observational study of umbilical cord clamping practices of maternity care providers in a tertiary care center.

    Science.gov (United States)

    Hutton, Eileen K; Stoll, Kathrin; Taha, Natalie

    2013-03-01

    Severing the umbilical cord at birth is likely the oldest intervention, the timing of which remains fraught with controversy. Emerging evidence suggests benefit in delaying cord clamping for both term and preterm infants. The objective of this study was to investigate actual cord clamping time and circumstances at a large tertiary care center in Canada. We used a stopwatch to time the interval from the time the infant was born as far as the umbilicus until the time that the umbilical cord was clamped before cutting. We reported on timing of the umbilical cord clamping overall and by practitioner group (obstetrician, midwife, and family practitioner). A total of 98 women and their practitioners consented to be observed at the British Columbia Women's Hospital and Health Center, Vancouver, Canada. More than one-half (56.2%) of all infants had their umbilical cord clamped within 15 seconds. The median (5th, 95th percentile) clamping time in seconds for the full sample was 12 (4, 402) with practitioner subgroups as follows: obstetricians (12 [3, 107]), family physicians (19 [6, 325]), and midwives (81 [6, undefined]). The median clamping time was likely to be longer when the birth occurred spontaneously, no umbilical cord blood was collected, and no birth or neonatal complications occurred. In our sample taken in 2006 to 2007, most infants had umbilical cords clamped immediately after the birth, with more than one-half clamped within 15 seconds of birth. Since the time of our study, delayed umbilical cord clamping for the healthy term newborn has become a part of recommended management of third stage of labor and resuscitation guidelines. It would be informative to repeat a study like this one to determine compliance with the current standards of care. © 2013, Copyright the Authors Journal compilation © 2013, Wiley Periodicals, Inc.

  7. Off-clamp robot-assisted partial nephrectomy does not benefit short-term renal function: a matched cohort analysis.

    Science.gov (United States)

    Anderson, Barrett G; Potretzke, Aaron M; Du, Kefu; Vetter, Joel; Figenshau, R Sherburne

    2017-08-31

    In the interest of renal functional preservation, partial nephrectomy has supplanted radical nephrectomy as the preferred treatment for T1 renal masses. This procedure usually involves the induction of renal warm ischemia by clamping the hilar vessels prior to tumor excision. Performing robot-assisted partial nephrectomy (RAPN) "off-clamp" can theoretically prevent renal functional loss associated with warm ischemia. We describe our institutional experience and compare perioperative and renal functional outcomes using a propensity score matched cohort. We conducted a retrospective comparison from a prospectively maintained database of all patients who underwent RAPN from 2009 to 2015. Of those patients, 143 underwent off-clamp RAPN. Fifty off-clamp RAPN patients were propensity score matched with fifty clamped RAPN patients based on renal function, tumor size, and R.E.N.A.L. nephrometry score. The cohorts were compared across demographics, operative information, perioperative outcomes, and renal functional outcomes. For all off-clamp RAPN patients, mean nephrometry score was 7.1, mean estimated blood loss (EBL) was 236.9 mL, perioperative complication rate was 7.7%, and mean decrease in estimated glomerular filtration rate (eGFR) was 7.1% at a median follow-up of 9.2 months. In the propensity score matched cohorts, off-clamp RAPN resulted in a shorter mean operative time (172.0 versus 196.0 min, p = 0.025) and a lower mean EBL (179.7 versus 283.2 mL, p = 0.046). A lower complication rate of 6.0% in the off-clamp group compared with 20.0% in the clamped group approached significance (p = 0.071). Mean preoperative eGFR was similar in both cohorts. Importantly, there was no significant difference in decrease in eGFR between the clamped cohort (9.8%) and off-clamp cohort (11.9%) at a median follow-up of 9.0 months (p = 0.620). Off-clamp RAPN did not result in improved renal functional preservation in our experience. Surprisingly, the off-clamp cohort

  8. Induction of DNA DSB and its rejoining in clamped and non-clamped tumours after exposure to carbon ion beams in comparison to X rays.

    Science.gov (United States)

    Hirayama, R; Uzawa, A; Matsumoto, Y; Noguchi, M; Kase, Y; Takase, N; Ito, A; Koike, S; Ando, K; Okayasu, R; Furusawa, Y

    2011-02-01

    We studied double-strand breaks (DSB) induction and rejoining in clamped and non-clamped transplanted tumours in mice leg after exposure to 80 keV µm(-1) carbon ions and X rays. The yields of DSB in the tumours were analysed by a static-field gel electrophoresis. The OER of DSB after X rays was 1.68±0.31, and this value was not changed after 1 h rejoining time (1.40±0.26). These damages in oxygenated conditions were rejoined 60-70% within 1 h in situ. No difference was found between the exposure to X rays and carbon ions for the induction and rejoining of DSB. Thus, the values of OER and rejoined fraction after exposure to carbon ions were similar to those after X rays, and the calculated relative biological effectivenesses of carbon ion were around 1 under both oxygen conditions. The yields of DSB in vivo depend on exposure doses, oxygen conditions and rejoining time, but not on the types of radiation quality.

  9. Hydraulic Conductivity Anisotropy of Heterogeneous Unsaturated Soils

    Science.gov (United States)

    Sun, Dongmin; Zhu, Jianting

    2010-05-01

    The effects of saturation degree (or capillary pressure) on hydraulic conductivity anisotropy in unsaturated soils have not been fully understood. This study developed an approach based on a conceptualization of combining the neural network based pedo-transfer function (PTF) results with the thin layer concept to explore the capillary pressure-dependent anisotropy in relation to soil texture and soil bulk density. The main objective is to examine how anisotropy characteristics are related to the relationships between hydraulic parameters and the basic soil attributes such as texture and bulk density. The hydraulic parameters are correlated with the texture and bulk density based on the pedo-transfer function (PTF) results. It is demonstrated that non-monotonic behavior of the unsaturated soil anisotropy in relation to the capillary pressure is only observed when the saturated hydraulic conductivity and the shape parameter are both related to the mean particle diameter. When only one hydraulic parameter is related to the grain diameter or when both are not related to the same attribute simultaneously, the unsaturated soil anisotropy increases monotonically with the increasing capillary pressure head. Therefore, it is suggested that this behavior is mainly due to the coupled dependence of the layer saturated hydraulic conductivities and the shape factors on the texture and bulk density. The correlation between the soil grain diameter and bulk density decreases the anisotropy effects of the unsaturated layered soils. The study illustrates that the inter-relationships of soil texture, bulk density, and hydraulic properties may cause vastly different characteristics of anisotropic unsaturated soils.

  10. Thermal-hydraulic modeling and analysis of hydraulic system by pseudo-bond graph

    Institute of Scientific and Technical Information of China (English)

    胡均平; 李科军

    2015-01-01

    To increase the efficiency and reliability of the thermodynamics analysis of the hydraulic system, the method based on pseudo-bond graph is introduced. According to the working mechanism of hydraulic components, they can be separated into two categories: capacitive components and resistive components. Then, the thermal-hydraulic pseudo-bond graphs of capacitive C element and resistance R element were developed, based on the conservation of mass and energy. Subsequently, the connection rule for the pseudo-bond graph elements and the method to construct the complete thermal-hydraulic system model were proposed. On the basis of heat transfer analysis of a typical hydraulic circuit containing a piston pump, the lumped parameter mathematical model of the system was given. The good agreement between the simulation results and experimental data demonstrates the validity of the modeling method.

  11. Design and experimental research of a novel inchworm type piezo-driven rotary actuator with the changeable clamping radius.

    Science.gov (United States)

    Zhao, Hongwei; Fu, Lu; Ren, Luquan; Huang, Hu; Fan, Zunqiang; Li, Jianping; Qu, Han

    2013-01-01

    In this paper, a novel piezo-driven rotary actuator with the changeable clamping radius is developed based on the inchworm principle. This actuator mainly utilizes three piezoelectric actuators, a flexible gripper, a clamping block, and a rotor to achieve large stroke rotation with high resolution. The design process of the flexible gripper consisting of the driving unit and the clamping unit is described. Lever-type mechanisms were used to amplify the micro clamping displacements. The amplifying factor and parasitic displacement of the lever-type mechanism in the clamping unit was analyzed theoretically and experimentally. In order to investigate the rotation characteristics of the actuator, a series of experiments was carried out. Experimental results indicate that the actuator can rotate at a speed of 77,488 μrad/s with a driving frequency of 167 Hz. The rotation resolution and maximum load torque of the actuator are 0.25 μrad and 37 N mm, respectively. The gripper is movable along the z direction based on an elevating platform, and the clamping radius can change from 10.6 mm to 25 mm. Experimental results confirm that the actuator can achieve different rotation speeds by changing the clamping radius.

  12. Conformal analysis of fundamental frequency of vibration of elastic clamped plates

    Institute of Scientific and Technical Information of China (English)

    QI Hongyuan; ZHU Hengjun

    2007-01-01

    To calculate the fundamental frequency of vibration of special-shaped and elastic clamped plates, the conformal mapping theory is adopted to separate the interpolating points of a complicated boundary into odd and even sequences,both of which can be mutually iterated, so that the conformal mapping function between the complicated region and the unit dish region is established. Trigonometric interpolation and convergence along the normal direction methods are provided, and the complex coefficients of the conformal mapping function are calculated. Galerkin method is used to obtain the solution of fundamental frequency in the vibrating differential function of the complicated vibrating region.Finally, taking ellipse elastic clamped plates as an example,the effects on fundamental frequency coefficient caused by eccentric ratio e and area size are analyzed.

  13. Testing and evaluation of stretching strain in clamped–clamped beams for energy harvesting

    Science.gov (United States)

    Emad, Ahmed; Mahmoud, Mohamed A. E.; Ghoneima, Maged; Dessouky, Mohamed

    2016-11-01

    In this paper, evaluation of stretching strain capabilities to harvest energy from a piezoelectric clamped–clamped beam is theoretically modeled and experimentally tested. The utilization of stretching strain has many advantages as: elimination of any substrate material, and the simple electrode configuration. The doubly clamped structure exhibits a highly nonlinear frequency response (Hardening Duffing) that widens the bandwidth during the frequency up-ward sweep. The wide bandwidth makes it suitable for practical applications. A design of 53.5 {{mm}}3 (29.7 {{mm}}3 piezoelectric material + 23.8 {{mm}}3 proof mass) energy harvester was tested using PVDF (polyvinylidene fluoride) that can generate up to 15 μW from vibrations of 0.5{g} at 128 {Hz} and 2 MΩ load. The design can also generate up to 41 μ {{W}} from vibrations of 1{g} at 140 {Hz} and 2 MΩ load.

  14. Detailed Theoretical Model for Adjustable Gain-Clamped Semiconductor Optical Amplifier

    Directory of Open Access Journals (Sweden)

    Lin Liu

    2012-01-01

    Full Text Available The adjustable gain-clamped semiconductor optical amplifier (AGC-SOA uses two SOAs in a ring-cavity topology: one to amplify the signal and the other to control the gain. The device was designed to maximize the output saturated power while adjusting gain to regulate power differences between packets without loss of linearity. This type of subsystem can be used for power equalisation and linear amplification in packet-based dynamic systems such as passive optical networks (PONs. A detailed theoretical model is presented in this paper to simulate the operation of the AGC-SOA, which gives a better understanding of the underlying gain clamping mechanics. Simulations and comparisons with steady-state and dynamic gain modulation experimental performance are given which validate the model.

  15. High Efficiency Interleaved Active Clamped Dc-Dc Converter with Fuel Cell for High Voltage Applications

    Directory of Open Access Journals (Sweden)

    Sona P

    2014-02-01

    Full Text Available A high efficiency interleaved ZVS active clamped current fed dc-dc converter is proposed in this paper specially used for fuel cell applications. As the fuel cell output is very low we are in need of a step up dc-dc converter. Here a current fed dc-dc converter is used. Two current fed dc-dc converters are interleaved by connecting their inputs in parallel and outputs in series. With this proposed methodology input current ripples in the fuel cell stacks can be reduced and a regulated output voltage ripples can be obtained. The active clamping circuit used in this model absorbs the turn off voltage spikes hence low voltage devices with low on state resistance can be used.Voltage doubler circuits will give double the output voltage than normal with smaller transformer turns ratio and flexibility. The proposed method is simulated in MATLAB for verifying the accuracy of the proposed design.

  16. Influence of non-steady state during isoglycemic hyperinsulinemic clamp in hypertension. A LIFE substudy

    DEFF Research Database (Denmark)

    Olsen, M H; Andersen, U B; Wachtell, K;

    1999-01-01

    We wanted to investigate whether time to steady state was reached within 2 h of insulin infusion during isoglycemic hyperinsulinemic clamp, comparing the glucose uptake index (M/IG) with Bergman's insulin sensitivity index (Sip). We performed a 2-h oral glucose tolerance test and a 3-h isoglycemic...... hyperinsulinemic clamp in 26 young, healthy subjects and 43 elderly patients with unmedicated essential hypertension and left ventricular hypertrophy. The 3-h Sip correlated strongly with the 2-h M/IG in the patients (r = 0.88, p ... narrow limits of agreement in the patients. However, during the third hour of insulin infusion, M/IG (10.0 vs 12.21(2) x kg(-1) x min(-1) x mmol(-1), p Sip (7.1 vs 9.41(2) x kg(-1) x min(-1) x mmol(-1), p

  17. Implementation and Tuning of an Optical Tweezers Force-Clamp Feedback System.

    Science.gov (United States)

    Bugiel, Michael; Jannasch, Anita; Schäffer, Erik

    2017-01-01

    Feedback systems can be used to control the value of a system variable. In optical tweezers, active feedback is often implemented to either keep the position or tension applied to a single biomolecule constant. Here, we describe the implementation of the latter: an optical force-clamp setup that can be used to study the motion of processive molecular motors under a constant load. We describe the basics of a software-implemented proportional-integral-derivative (PID) controller, how to tune it, and how to determine its optimal feedback rate. Limitations, possible feed-forward applications, and extensions into two- and three-dimensional optical force clamps are discussed. The feedback is ultimately limited by thermal fluctuations and the compliance of the involved molecules. To investigate a particular mechanical process, understanding the basics and limitations of the feedback system will be helpful for choosing the proper feedback hardware, for optimizing the system parameters, and for the design of the experiment.

  18. Study of transmembrane La3+ movement in rat ventricular myocytes by the patch-clamp technique

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    We have studied transmembrane La3+ movement in rat ventricular myocytes for the first time by using the whole-cell patch-clamp recording mode. La3+ (0.01-5.0 mmol/L) could not bring out inward currents through the L-type calcium channel in rat ventricular myocytes, while it could enter the cells by the same way carried by 1μmol/L ionomycin. When the outward Na+ concentration gradient is formed, La3+ can enter the cells via Na-Ca exchange, and the exchange currentsincrease with the increase of external La3+ concentrations. But compared with Na-Ca exchange currents in the same concentration, the former is only 14%-38% of the latter. The patch-clamp experiment indicates that La3+ normally can not enter ventricular myocytes through L-type calcium channel, but it can enter the cells via Na-Ca exchange.

  19. [Traumatic section of the thoracic aorta: its repair by direct aortic clamping].

    Science.gov (United States)

    Cairols, M A; Sieyro, F; Miralles, M; Blanes, I; Lozano, P

    1991-01-01

    Traumatic section of descendent aorta, severe complication of a thoracic traumatism, requires an early recognition and restoration because its high mortality rate. Between 1988 and 1990, three patients underwent surgical approach, by direct aortic clamping [correction of clamplaje], at our Service. In two cases, a heart stoppage appeared during the clamping/unclamping [correction of clampaje/desclampaje] maneuvers. One of them had previously electrocardiographic abnormalities, suggestive of heart contusion. Two patients died, one of them during surgical procedure because an irreversible heart stoppage, and the second patient died after 7 days because of a brain hemorrhage. One case presented postoperative paraplegia. Respective rates and literature about the main factors implicated in the diagnosis and treatment of such pathology are reviewed.

  20. Short Hypoxia Does not Affect Plasma Leptin in Healthy Men under Euglycemic Clamp Conditions

    Directory of Open Access Journals (Sweden)

    Andre Schmoller

    2009-01-01

    Full Text Available Leptin is involved in the endocrine control of energy expenditure and body weight regulation. Previous studies emphasize a relationship between hypoxic states and leptin concentrations. The aim of this study was to investigate the effects of acute hypoxia on leptin concentrations in healthy subjects. We examined 14 healthy men. Hypoxic conditions were induced by decreasing oxygen saturation to 75% for 30 minutes. Plasma leptin concentrations were determined at baseline, after 3 hours of euglycemic clamping, during hypoxia, and repeatedly the following 2.5 hours thereafter. Our results show an increase of plasma leptin concentrations in the course of 6 hours of hyperinsulinemic-euglycemic clamping which may reflect diurnal rhythmicity. Notwithstanding, there was no difference between levels of leptin in the hypoxic and the normoxic condition (=.2. Since we did not find any significant changes in leptin responses upon hypoxia, plasma leptin levels do not seem to be affected by short hypoxic episodes of moderate degree.

  1. [The Impact of Late Umbilical Cord Clamping on Neonatal Jaundice and Postpartum Hemorrhage: A Randomized Controlled Trail].

    Science.gov (United States)

    Chien, Pei-Chun; Yang, Cherng-Chia; Gau, Meei-Ling; Liu, Chieh-Yu; Lee, Tzu-Ying

    2015-08-01

    The current evidence supports the clinical benefits of late umbilical cord clamping. These benefits include increased blood volume and total body iron. Furthermore, delayed cord clamping facilitates the transplantation of stem cells, which helps the development of infant bodily systems. However, due to concerns related to postpartum hemorrhaging and neonate jaundice, most maternity units still clamp the cord immediately after a child is born. This study investigates the impact of delaying cord clamping on neonatal jaundice and postpartum hemorrhage. A randomized, controlled trial was conducted at a regional teaching hospital in northern Taiwan. One hundred and five healthy nulliparous women at 36 weeks of pregnancy were included and allocated randomly to the experiment group (n=44) and the control group (n=61). Participants in the experiment group received delayed cord clamping (DCC) at 3 minutes after delivery. Participants in the control group received early cord clamping (ECC) at around 1 minute after delivery. Clinical measures of the outcomes were measured by the infant transcutaneous bilirubin levels (TcB) and postpartum hemorrhage at birth. A structured questionnaire and biophysical measures were used to collect data on participant demographics, obstetrical information, maternal blood loss at birth, neonate weight and TcB level at hospitalization, and whether or not the infant received phototherapy at 4-7 days postpartum. Overall, there was no significant difference between the two groups in terms of neonatal jaundice, maternal hemorrhage at birth, and phototherapy rates at time of hospitalization and at 4-7 days postpartum. The findings of the present study support that late umbilical cord clamping does not increase the risk of maternal postpartum hemorrhaging or neonate jaundice. Thus, we suggest that clinicians inform clients during prenatal classes of the benefits of delayed cord clamping and also use current, evidence-based knowledge to dispel client

  2. Effect of Natural Fractures on Hydraulic Fracturing

    Science.gov (United States)

    Ben, Y.; Wang, Y.; Shi, G.

    2012-12-01

    Hydraulic Fracturing has been used successfully in the oil and gas industry to enhance oil and gas production in the past few decades. Recent years have seen the great development of tight gas, coal bed methane and shale gas. Natural fractures are believed to play an important role in the hydraulic fracturing of such formations. Whether natural fractures can benefit the fracture propagation and enhance final production needs to be studied. Various methods have been used to study the effect of natural fractures on hydraulic fracturing. Discontinuous Deformation Analysis (DDA) is a numerical method which belongs to the family of discrete element methods. In this paper, DDA is coupled with a fluid pipe network model to simulate the pressure response in the formation during hydraulic fracturing. The focus is to study the effect of natural fractures on hydraulic fracturing. In particular, the effect of rock joint properties, joint orientations and rock properties on fracture initiation and propagation will be analyzed. The result shows that DDA is a promising tool to study such complex behavior of rocks. Finally, the advantages of disadvantages of our current model and future research directions will be discussed.

  3. Microbial effect on soil hydraulic properties

    Science.gov (United States)

    Furman, Alex; Rosenzweig, Ravid; Volk, Elazar; Rosenkranz, Hella; Iden, Sascha; Durner, Wolfgang

    2014-05-01

    Although largely ignored, the soil contains large amount of biofilms (attached microbes) that can affect many processes. While biochemical processes are studied, biophysical processes receive only little attention. Biofilms may occupy some of the pore space, and by that affect the soil hydraulic properties. This effect on unsaturated soils, however, was not intensively studied. In this research we directly measure the hydraulic properties, namely the soil's unsaturated hydraulic conductivity function and retention curve, for soils containing real biofilm. To do that we inoculate soil with biofilm-forming bacteria and incubate it with sufficient amounts of nutrient until biofilm is formed. The hydraulic properties of the incubated soil are then measured using several techniques, including multi-step outflow and evaporation method. The longer measurements (evaporation method) are conducted under refrigeration conditions to minimize microbial activity during the experiment. The results show a clear effect of the biofilm, where the biofilm-affected soil (sandy loam in our case) behaves like a much finer soil. This qualitatively makes sense as the biofilm generates an effective pore size distribution that is characterized by smaller pores. However, the effect is much more complex and needs to be studied carefully considering (for example) dual porosity models. We compare our preliminary results with other experiments, including flow-through column experiments and experiments with biofilm analogues. Clearly a better understanding of the way microbial activity alters the hydraulic properties may help designing more efficient bioremediation, irrigation, and other soil-related processes.

  4. Vibration Isolation for Parallel Hydraulic Hybrid Vehicles

    Directory of Open Access Journals (Sweden)

    The M. Nguyen

    2008-01-01

    Full Text Available In recent decades, several types of hybrid vehicles have been developed in order to improve the fuel economy and to reduce the pollution. Hybrid electric vehicles (HEV have shown a significant improvement in fuel efficiency for small and medium-sized passenger vehicles and SUVs. HEV has several limitations when applied to heavy vehicles; one is that larger vehicles demand more power, which requires significantly larger battery capacities. As an alternative solution, hydraulic hybrid technology has been found effective for heavy duty vehicle because of its high power density. The mechanical batteries used in hydraulic hybrid vehicles (HHV can be charged and discharged remarkably faster than chemical batteries. This feature is essential for heavy vehicle hybridization. One of the main problems that should be solved for the successful commercialization of HHV is the excessive noise and vibration involving with the hydraulic systems. This study focuses on using magnetorheological (MR technology to reduce the noise and vibration transmissibility from the hydraulic system to the vehicle body. In order to study the noise and vibration of HHV, a hydraulic hybrid subsystem in parallel design is analyzed. This research shows that the MR elements play an important role in reducing the transmitted noise and vibration to the vehicle body. Additionally, locations and orientations of the isolation system also affect the efficiency of the noise and vibration mitigation. In simulations, a skyhook control algorithm is used to achieve the highest possible effectiveness of the MR isolation system.

  5. Early versus delayed cord clamping in term and preterm births: a review.

    Science.gov (United States)

    Garofalo, Milena; Abenhaim, Haim A

    2012-06-01

    The optimal timing for cord clamping, early versus delayed, in the third stage of labour is a controversial subject. Issues surrounding the timing of cord clamping include gestational age and maternal and neonatal considerations. Delayed cord clamping (DCC) has been shown to increase placental transfusion, leading to an increase in neonatal blood volume at birth of approximately 30%. In the term infant, although this may result in an increase in iron stores, thereby decreasing the risk of anemia, it may adversely increase the risk of jaundice and the need for phototherapy. In the preterm infant, DCC (or even milking of the cord) decreases the need for blood transfusions for anemia, the number of such transfusions, and the risks of intraventricular hemorrhage and late-onset sepsis. Advantages of DCC also include a reduction in alloimmunization in Rh-negative women, although this advantage is theoretical and unproven. We searched multiple databases including PubMed Clinical Queries, Trip Database, Cochrane Systematic Reviews, and UpToDate, as well as published guidelines from the Society of Obstetricians and Gynaecologists of Canada, the American Congress of Obstetricians and Gynecologists, and the Royal College of Obstetricians and Gynaecologists. We preferentially selected systematic reviews and randomized controlled trials for this literature review. Overall, the available evidence appears to suggest that DCC is likely to result in better neonatal outcomes in both term and preterm infants, even in areas where neonatal iron deficiency anemia is rare. However, there is insufficient evidence to date to support a recommendation to delay cord clamping in non-vigorous infants requiring resuscitation.

  6. MATLAB-based automated patch-clamp system for awake behaving mice

    OpenAIRE

    Desai, Niraj S.; Siegel, Jennifer J.; Taylor, William; Chitwood, Raymond A.; Johnston, Daniel

    2015-01-01

    Automation has been an important part of biomedical research for decades, and the use of automated and robotic systems is now standard for such tasks as DNA sequencing, microfluidics, and high-throughput screening. Recently, Kodandaramaiah and colleagues (Nat Methods 9: 585–587, 2012) demonstrated, using anesthetized animals, the feasibility of automating blind patch-clamp recordings in vivo. Blind patch is a good target for automation because it is a complex yet highly stereotyped process th...

  7. Diode-clamped multilevel converters with integrable gate-driver power-supply circuits

    OpenAIRE

    Busquets Monge, Sergio; Rocabert Delgado, Joan; Crébier, Jean-Christophe; Peracaula Roura, Joan

    2009-01-01

    International audience; Recent contributions in pulse width modulations (PWM) for multilevel diode-clamped converters enable the use of these converters with passive front-ends, any number of levels, and small dc-link capacitors. Highly compact converters designs based on these topologies can be envisioned. However, the design of the gate-driver power-supply for the multiple controlled semiconductor devices remains an important issue to be addressed. This paper focuses on the design of such c...

  8. New device for saphenous vein-to-aorta proximal anastomosis without side-clamping

    Directory of Open Access Journals (Sweden)

    Tappainer Ernesto

    2007-05-01

    Full Text Available Abstract Background Side clamping to perform saphenous vein-to-aorta proximal anastomosis is a well known cause of cerebral embolization during coronary bypass surgery. Automatic and manual devices have been introduced to avoid aortic clamping and facilitate proximal anastomosis but the manual ones only allow the traditional hand-sewing running suture. Nevertheless, they are not easy to use and very expensive to buy. Methods We developed a simple object that helps to perform a manual proximal anastomosis without the need to clamp the side of the aorta. This device is a steel bar which blocks the aortic hole and simultaneously it provides a slit to receive the needle. Through the slit comes out a thin, sharp, straight, but also well directed and predictable jet of blood which could be easily controlled during the suture. Results The function of the object is quite different from other devices. Nothing is deployed in the aorta. The object is only placed on the aorta with the small appendage slipped into the hole. The main advantage of the device is that while manipulation of the aorta is avoided no foreign bodies are incorporated in the suture and – most importantly – the aortic intima is not touched at all. The main drawback of the device is the blood jet coming from the slit so that the blood pressure has to be lowered by vasodilators during the anastomosis. Moreover, the suture has to change direction and the needle has to enter the aortic wall first to slip out through the slit. Conclusion The object was named "Slit Device" and is not a routine instrument. It would be only an alternative to other anastomotic devices with the same surgical indications. In the case of ascending aortic disease and saphenous vein grafting, the Slit Device avoids aortic clamping thereby preventing atheroembolism and also avoiding the need for hypothermic circulatory arrest in patients with unclampable aorta.

  9. A complete dc characterization of a constant-frequency, clamped-mode, series-resonant converter

    Science.gov (United States)

    Tsai, Fu-Sheng; Lee, Fred C.

    1988-01-01

    The dc behavior of a clamped-mode series-resonant converter is characterized systematically. Given a circuit operating condition, the converter's mode of operation is determined and various circuit parameters are calculated, such as average inductor current (load current), rms inductor current, peak capacitor voltage, rms switch currents, average diode currents, switch turn-on currents, and switch turn-off currents. Regions of operation are defined, and various circuit characteristics are derived to facilitate the converter design.

  10. Generation of high-performance binding proteins for peptide motifs by affinity clamping

    OpenAIRE

    Koide, Shohei; Huang, Jin

    2013-01-01

    We describe concepts and methodologies for generating “Affinity Clamps”, a new class of recombinant binding proteins that achieve high affinity and high specificity toward short peptide motifs of biological importance, which is a major challenge in protein engineering. The Affinity Clamping concept exploits the potential of nonhomologous recombination of protein domains in generating large changes in protein function and the inherent binding affinity and specificity of the so-called modular i...

  11. Adverse impact of intermittent portal clamping on long-term postoperative outcomes in hepatocellular carcinoma.

    Science.gov (United States)

    Hao, S; Chen, S; Yang, X; Wan, C

    2017-01-01

    Introduction To evaluate the impact of intermittent portal clamping (IPC) on long-term postoperative outcomes in patients with hepatocellular carcinoma (HCC). Methods Clinical records of 355 patients underwent curative liver resection for HCC in January 2007 to December 2010 were retrospectively reviewed. According to how portal clamping was performed, patients were grouped as: IPC, n=113; other portal clamping (OPC), n=190; and no portal clamping (NPC), n=52. Results Median recurrence-free survival (RFS) was statistically significantly shorter in the IPC (39.4 months) than OPC (47.3 months, p=0.010) and NPC groups (51.4 months, p=0.008). Median overall survival (OS) was also significantly shorter with IPC (46.3 months), versus 52.9 months with OPC (p=0.022) and 56.2 months with NPC (p=0.015). Kaplan-Meier survival analysis revealed that 5-year cumulative RFS was much lower in the IPC (42.5%) than OPC (50.9%, p=0.014) and NPC groups (49.6%, p=0.013). Five-year cumulative OS was also much lower in the IPC (44.9%) than OPC (58.0%, p=0.020) and NPC groups (57.7%, p=0.025). On univariate analysis, tumour grade, size and number, TNM stage, blood transfusion, vascular invasion and IPC were significantly inversely correlated with RFS and OS. On multivariate analysis, tumour size and number, blood transfusion, vascular invasion and IPC remained significant. Conclusions Our study suggests that IPC is an independent risk factor for poor long-term postoperative outcomes in patients with HCC.

  12. Microwave electromechanical resonator consisting of clamped carbon nanotubes in an abacus arrangement

    Science.gov (United States)

    Peng, H. B.; Chang, C. W.; Aloni, S.; Yuzvinsky, T. D.; Zettl, A.

    2007-07-01

    We describe nanoscale electromechanical resonators capable of operating in ambient-pressure air at room temperature with unprecedented fundamental resonance frequency of ˜4GHz . The devices are created from suspended carbon nanotubes loaded abacus style with inertial metal clamps, yielding short effective beam lengths. We examine the energy dissipation in the system due to air damping and contact loss. Such nanoabacus resonators open windows for immediate practical microwave frequency nanoelectromechanical system applications.

  13. Designing a Signal Conditioning System with Software Calibration for Resistor-feedback Patch Clamp Amplifier.

    Science.gov (United States)

    Hu, Gang; Zhu, Quanhui; Qu, Anlian

    2005-01-01

    In this paper, a programmable signal conditioning system based on software calibration for resistor-feedback patch clamp amplifier (PCA) has been described, this system is mainly composed of frequency correction, programmable gain and filter whose parameters are configured by software automatically to minimize the errors, A lab-designed data acquisition system (DAQ) is used to implement data collections and communications with PC. The laboratory test results show good agreement with design specifications.

  14. Exponential Attractor for the Boussinesq Equation with Strong Damping and Clamped Boundary Condition

    OpenAIRE

    Fan Geng; Ruizhai Li; Xiaojun Zhang; Xiangyu Ge

    2016-01-01

    The paper studies the existence of exponential attractor for the Boussinesq equation with strong damping and clamped boundary condition utt-Δu+Δ2u-Δut-Δg(u)=f(x). The main result is concerned with nonlinearities g(u) with supercritical growth. In that case, we construct a bounded absorbing set with further regularity and obtain quasi-stability estimates. Then the exponential attractor is established in natural energy space V2×H.

  15. Prediction of numerical distortion after welding with various welding sequences and clampings

    Directory of Open Access Journals (Sweden)

    S. Kastelic

    2010-10-01

    Full Text Available Welding simulation of a test cover for hydropower plant was made due to very large dimensions of the cover. The main aim was to predict distortion after welding in order to avoid machining the cover. Welding process was simulated with the Sysweld program to keep distortion in desired limits. Various welding sequences and clamping conditions were calculated to reduce the distortion. Calculation of microstructure constituents in virtual complex geometry of joints was also analyzed.

  16. Direct-conversion switching-mode audio power amplifier with active capacitive voltage clamp

    DEFF Research Database (Denmark)

    Ljusev, Petar; Andersen, Michael Andreas E.

    2005-01-01

    This paper discusses the advantages and problems when implementing direct energy conversion switching-mode audio power amplifiers. It is shown that the total integration of the power supply and Class D audio power amplifier into one compact direct converter can simplify the design, increase...... efficiency, reduce the product volume and lower its cost. As an example, the principle of operation and the measurements made on a direct-conversion switching-mode audio power amplifier with active capacitive voltage clamp are presented....

  17. A Computational Model of Hydraulic Volume Displacement Drive

    Directory of Open Access Journals (Sweden)

    V. N. Pil'gunov

    2014-01-01

    Full Text Available The paper offers a computational model of industrial-purpose hydraulic drive with two hydraulic volume adjustable working chamber machines (pump and motor. Adjustable pump equipped with the pressure control unit can be run together with several adjustable hydraulic motors on the principle of three-phase hydraulic socket-outlet with high-pressure lines, drain, and drainage system. The paper considers the pressure-controlled hydrostatic transmission with hydraulic motor as an output link. It shows a possibility to create a saving hydraulic drive using a functional tie between the adjusting parameters of the pump and hydraulic motor through the pressure difference, torque, and angular rate of the hydraulic motor shaft rotation. The programmable logic controller can implement such tie. The Coulomb and viscous frictions are taken into consideration when developing a computational model of the hydraulic volume displacement drive. Discharge balance considers external and internal leakages in equivalent clearances of hydraulic machines, as well as compression loss volume caused by hydraulic fluid compressibility and deformation of pipe walls. To correct dynamic properties of hydraulic drive, the paper offers that in discharge balance are included the additional regulated external leakages in the open circuit of hydraulic drive and regulated internal leakages in the closed-loop circuit. Generalized differential equations having functional multipliers and multilinked nature have been obtained to describe the operation of hydraulic positioning and speed drive with two hydraulic volume adjustable working chamber machines. It is shown that a proposed computational model of hydraulic drive can be taken into consideration in development of LS («Load-Sensing» drives, in which the pumping pressure is tuned to the value required for the most loaded slave motor to overcome the load. Results attained can be used both in designing the industrial-purpose heavy

  18. A capacitor-clamped inverter based torsional oscillation damping method for electromechanical drivetrains

    Directory of Open Access Journals (Sweden)

    Shagar Viknash

    2016-01-01

    Full Text Available A typical electromechanical drivetrain consists of an electric motor, connecting shafts and gears. Premature failures of these shafts and gears have been reported which are mainly due to fatigue caused by extreme loads and torsional oscillations. Overdesign and passive damping are the common approaches taken to increase the fatigue life. Nevertheless, they increase the system cost, weight and volume. Alternatively, active damping through advanced inverter control of the motor drive has been identified as a promising solution that does not require overdesign or alterations to the existing system. Even with the active damping control, oscillations propagate into the dc side of the power converter and subsequently to the upstream power bus. Generally, a large capacitor or an additional energy storage system is placed to suppress these oscillations. This paper proposes to use the clamping capacitors of the capacitor-clamped inverter as energy storage elements and thereby eliminate the need for a large dc side capacitor or an additional energy storage system. The efficacy of the proposed method has been verified with computer simulations. Simulation results show that the clamping capacitors are capable of containing torsional oscillations within the inverter without passing them to the upstream power bus.

  19. Desktop Software for Patch-Clamp Raw Binary Data Conversion and Preprocessing

    Directory of Open Access Journals (Sweden)

    Ning Zhang

    2011-01-01

    Full Text Available Since raw data recorded by patch-clamp systems are always stored in binary format, electrophysiologists may experience difficulties with patch clamp data preprocessing especially when they want to analyze by custom-designed algorithms. In this study, we present desktop software, called PCDReader, which could be an effective and convenient solution for patch clamp data preprocessing for daily laboratory use. We designed a novel class module, called clsPulseData, to directly read the raw data along with the parameters recorded from HEKA instruments without any other program support. By a graphical user interface, raw binary data files can be converted into several kinds of ASCII text files for further analysis, with several preprocessing options. And the parameters can also be viewed, modified and exported into ASCII files by a user-friendly Explorer style window. The real-time data loading technique and optimized memory management programming makes PCDReader a fast and efficient tool. The compiled software along with the source code of the clsPulseData class module is freely available to academic and nonprofit users.

  20. Low noise patch-clamp current amplification by nanoparticles plasmonic-photonic coupling (analysis and modelling).

    Science.gov (United States)

    Haberal, E O; SalmanOgli, A; Nasseri, B

    2016-10-01

    In this article, a patch-clamp low noise current amplification based on nanoparticles plasmonic radiation is analyzed. It is well-known, a very small current is flowing from different membrane channels and so, for extra processing the current amplification is necessary. It is notable that there are some problems in traditional electronic amplifier due to its noise and bandwidth problem. Because of the important role of the patch-clamp current in cancer research and especially its small amplitude, it is vital to intensify it without adding any noises. In this study, the current amplification is performed firstly: from the excitement of nanoparticles by the patch-clamp pico-ampere current and then, the effect of nanoparticles plasmonic far-field radiation on conductor's carriers, which will cause the current amplification. This relates to the plasmonic-photonic coupling and their effect on conductor carriers as the current perturbation agent. In the steady state, the current amplification can reach to 1000 times of initial level. Furthermore, we investigated the nanoparticles morphology changing effect such as size, nanoparticles inter-distance, and nanoparticles distance from the conductor on the amplifier parameters. Finally, it should note that the original aim is to use nanoparticles plasmonic engineering and their coupling to photonics for output current manipulating.

  1. Molecular jamming—The cystine slipknot mechanical clamp in all-atom simulations

    Science.gov (United States)

    Pepłowski, Łukasz; Sikora, Mateusz; Nowak, Wiesław; Cieplak, Marek

    2011-02-01

    A recent survey of 17 134 proteins has identified a new class of proteins which are expected to yield stretching induced force peaks in the range of 1 nN. Such high force peaks should be due to forcing of a slip-loop through a cystine ring, i.e., by generating a cystine slipknot. The survey has been performed in a simple coarse grained model. Here, we perform all-atom steered molecular dynamics simulations on 15 cystine knot proteins and determine their resistance to stretching. In agreement with previous studies within a coarse grained structure based model, the level of resistance is found to be substantially higher than in proteins in which the mechanical clamp operates through shear. The large stretching forces arise through formation of the cystine slipknot mechanical clamp and the resulting steric jamming. We elucidate the workings of such a clamp in an atomic detail. We also study the behavior of five top strength proteins with the shear-based mechanostability in which no jamming is involved. We show that in the atomic model, the jamming state is relieved by moving one amino acid at a time and there is a choice in the selection of the amino acid that advances the first. In contrast, the coarse grained model also allows for a simultaneous passage of two amino acids.

  2. FPGA in-the-loop simulations of cardiac excitation model under voltage clamp conditions

    Science.gov (United States)

    Othman, Norliza; Adon, Nur Atiqah; Mahmud, Farhanahani

    2017-01-01

    Voltage clamp technique allows the detection of single channel currents in biological membranes in identifying variety of electrophysiological problems in the cellular level. In this paper, a simulation study of the voltage clamp technique has been presented to analyse current-voltage (I-V) characteristics of ion currents based on Luo-Rudy Phase-I (LR-I) cardiac model by using a Field Programmable Gate Array (FPGA). Nowadays, cardiac models are becoming increasingly complex which can cause a vast amount of time to run the simulation. Thus, a real-time hardware implementation using FPGA could be one of the best solutions for high-performance real-time systems as it provides high configurability and performance, and able to executes in parallel mode operation. For shorter time development while retaining high confidence results, FPGA-based rapid prototyping through HDL Coder from MATLAB software has been used to construct the algorithm for the simulation system. Basically, the HDL Coder is capable to convert the designed MATLAB Simulink blocks into hardware description language (HDL) for the FPGA implementation. As a result, the voltage-clamp fixed-point design of LR-I model has been successfully conducted in MATLAB Simulink and the simulation of the I-V characteristics of the ionic currents has been verified on Xilinx FPGA Virtex-6 XC6VLX240T development board through an FPGA-in-the-loop (FIL) simulation.

  3. A quality improvement initiative for delayed umbilical cord clamping in very low-birthweight infants.

    Science.gov (United States)

    Bolstridge, Jeff; Bell, Tracy; Dean, Barbara; Mackley, Amy; Moore, Gina; Swift, Cheryl; Viscount, Dina; Paul, David A; Pearlman, Stephen A

    2016-09-13

    Due to clinical benefits, delayed cord clamping (DCC) is recommended in infants born before 37 weeks gestational age. The objective was to institute a delayed cord clamping program and to evaluate clinical outcomes one year after initiation. This study occured at Christiana Care Health System, a tertiary care facility with a 52 bed level 3 Neonatal Intensive Care Unit (NICU). A multidisciplinary team created a departmental policy, a DCC protocol and educational programs to support the development of a DCC program. A year after initiation of DCC, we evaluated two cohorts of very low birth weight (VLBW) infants (cord clamping protocol and a decrease in the percentage of VLBW infants requiring red blood cell transfusion from 53.7 to 35.9 % (p = 0.003). We also found a decreased need for respiratory support in the second cohort with no increases in the balancing measures of admission hypothermia and jaundice requiring phototherapy. During the Control Phase ongoing monitoring and education has led to a 93.7 % compliance rate. A multidisciplinary team including key leadership from the obstetric and pediatric departments allowed for the rapid and safe implementation of DCC.

  4. An ANN Based Capicitor Voltage Balancing Method For Neutral Point Clamped Multi-Level Inverter

    Directory of Open Access Journals (Sweden)

    P.J.S. Praveen,

    2015-11-01

    Full Text Available Multi-level inverters are became popular for usage in medium voltage, low voltage power applications due to flexibility in control and better performance characteristics in terms of harmonic regulation. Neutral point clamped are popular as they require less number of sources as their input when compared with their counter parts i.e. cascaded multi-level inverters and found to be reliable when compared with flying capacitor based multi-level inverters. But when neutral clamped technologies are used for generation of three-phase voltages, the capacitors that are connected at input side experiences imbalance in their voltages, this makes neutral point clamped multi-level inverters less reliable. In the proposed work an attempt is made to study circuits that balances the capacitor voltages and a scheme is investigated for balancing the capacitor voltages. Method proposed in [1] uses PID controller for balancing the capacitor voltages. In this project PI based control scheme and artificial neural network (ANN based control scheme for the front end circuit shown in [1] are designed for achieving balance among the capacitor voltages. The proposed control scheme is simulated with the help of Simpowersystems block set and neural network toolbox of MATLAB software for different load conditions. Results obtained from ANN based controller and PI controller are presented.

  5. External mean flow influence on sound transmission through finite clamped double-wall sandwich panels

    Science.gov (United States)

    Liu, Yu; Catalan, Jean-Cédric

    2017-09-01

    This paper studies the influence of an external mean flow on the sound transmission through finite clamped double-wall sandwich panels lined with poroelastic materials. Biot's theory is employed to describe wave propagation in poroelastic materials and various configurations of coupling the poroelastic layer to the facing plates are considered. The clamped boundary of finite panels are dealt with by the modal superposition theory and the weighted residual (Garlekin) method, leading to a matrix equation solution for the sound transmission loss (STL) through the structure. The theoretical model is validated against existing theories of infinite sandwich panels with and without an external flow. The numerical results of a single incident wave show that the external mean flow has significant effects on the STL which are coupled with the clamped boundary effect dominating in the low-frequency range. The external mean flow also influences considerably the limiting incidence angle of the panel system and the effect of the incidence angle on the STL. However, the influences of the azimuthal angle and the external flow orientation are negligible.

  6. Characterization of potassium channel modulators with QPatch automated patch-clamp technology: system characteristics and performance.

    Science.gov (United States)

    Kutchinsky, Jonatan; Friis, Søren; Asmild, Margit; Taboryski, Rafael; Pedersen, Simon; Vestergaard, Ras K; Jacobsen, Rasmus B; Krzywkowski, Karen; Schrøder, Rikke L; Ljungstrøm, Trine; Hélix, Nathalie; Sørensen, Claus B; Bech, Morten; Willumsen, Niels J

    2003-10-01

    Planar silicon chips with 1-2-microm etched holes (average resistance: 2.04 +/- 0.02 MOmega in physiological buffer, n = 274) have been developed for patch-clamp recordings of whole-cell currents from cells in suspension. An automated 16-channel parallel screening system, QPatch 16, has been developed using this technology. A single-channel prototype of the QPatch system was used for validation of the patch-clamp chip technology. We present here data on the quality of patch-clamp recordings and from actual drug screening studies of human potassium channels expressed in cultured cell lines. Using Chinese hamster ovary (CHO) and human embryonic kidney cells (HEK), gigaseals of 4.1 +/- 0.4 GOmega (n = 146) and high-quality whole-cell current recordings were obtained from hERG and KCNQ4 potassium channels. Success rates for gigaseal recordings varied from 40 to 95%, and 67% of the whole-cell configurations lasted for >20 min. Cells were maintained in suspension up to 4 h in a cell storage facility that is integrated in the QPatch 16. No decline in patchability was observed during this time course. A series of screens was conducted with known inhibitors of the hERG and KCNQ4 potassium channels. Dose-response relationship characterizations of verapamil and rBeKm-1 blockage of hERG currents provided IC(50) values similar to values reported in the literature.

  7. Three Level Diode Clamped Inverter Fed Induction Motor with Dtc-Svm

    Directory of Open Access Journals (Sweden)

    V. Ranjith Kumar

    2013-09-01

    Full Text Available This project presents a three-level diode-clamped inverter feeding an asynchronous motor drive with direct torque control (DTC. The control method is based on DTC operating principles. The stator voltage vector reference is computed from the stator flux and torque errors imposed by the flux and torque controllers. This voltage reference is then generated using a diode-clamped inverter, where each phase of the inverter can be implemented using a dc source, which would be available from fuel cells, batteries, or ultra capacitors. This inverter provides nearly sinusoidal voltages with very low distortion, even without filtering, using fewer switching devices. In addition, the multilevel inverter can generate a high and fixed switching frequency output voltage with fewer switching losses, since only the small power cells of the inverter operate at a high switching rate. Therefore, a high performance and also efficient torque and flux controllers are obtained, enabling a DTC solution for multilevel-inverter-powered motor drives. The Pulse Width modulation technique for an inverter permits to obtain three phase system voltages, which can be applied to the controlled output. Space Vector Modulation (SVPWM principle differs from other PWM processes in the fact that all three drive signals for the inverter will be created simultaneously. The implementation of SVPWM process in digital systems necessitates less operation time and also less program memory. This project uses SVPWM technique for generation of pulses for three-level diode clamped inverter. Simulation is carried out on MATLAB-Simulink software.

  8. Measurement and evaluation of static characteristics of rotary hydraulic motor

    Directory of Open Access Journals (Sweden)

    Hružík Lumír

    2014-03-01

    Full Text Available The paper describes experimental equipment for measurement of static characteristics of rotary hydraulic motor. It is possible to measure flow, pressure, temperature, speed and torque by means of this equipment. It deals with measurement of static characteristics of a gear rotary hydraulic motor. Mineral oil is used as hydraulic liquid in this case. Flow, torque and speed characteristics are evaluated from measured parameters. Measured mechanical-hydraulic, flow and total efficiencies of the rotary hydraulic motor are adduced in the paper. It is possible to diagnose technical conditions of the hydraulic motor (eventually to recommend its exchange from the experimental measurements.

  9. Promoting water hydraulics in Malaysia: A green educational approach

    Science.gov (United States)

    Yusof, Ahmad Anas; Zaili, Zarin Syukri; Hassan, Siti Nor Habibah; Tuan, Tee Boon; Saadun, Mohd Noor Asril; Ibrahim, Mohd Qadafie

    2014-10-01

    In promoting water hydraulics in Malaysia, this paper presents research development of water hydraulics educational training system for secondary and tertiary levels in Malaysia. Water hydraulics trainer with robotic attachment has been studied in order to promote the usefulness of such educational tools in promoting sustainability and green technology in the country. The trainer is being developed in order to allow constructive curriculum development and continuous marketing research for the effectiveness and usefulness of using water in hydraulic power trainer. The research on water-based hydraulic trainer is now possible with the current development in water hydraulics technology.

  10. Hydraulic characterization of hydrothermally altered Nopal tuff

    Energy Technology Data Exchange (ETDEWEB)

    Green, R.T.; Meyer-James, K.A. [Southwest Research Institute, San Antonio, TX (United States); Rice, G. [George Rice and Associates, San Antonio, TX (United States)

    1995-07-01

    Understanding the mechanics of variably saturated flow in fractured-porous media is of fundamental importance to evaluating the isolation performance of the proposed high-level radioactive waste repository for the Yucca Mountain site. Developing that understanding must be founded on the analysis and interpretation of laboratory and field data. This report presents an analysis of the unsaturated hydraulic properties of tuff cores from the Pena Blanca natural analog site in Mexico. The basic intent of the analysis was to examine possible trends and relationships between the hydraulic properties and the degree of hydrothermal alteration exhibited by the tuff samples. These data were used in flow simulations to evaluate the significance of a particular conceptual (composite) model and of distinct hydraulic properties on the rate and nature of water flow.

  11. Simulation of a Hydraulic Pump Control Valve

    Science.gov (United States)

    Molen, G. Vander; Akers, A.

    1987-01-01

    This paper describes the mode of operation of a control valve assembly that is used with a hydraulic pump. The operating system of the valve is modelled in a simplified form, and an analogy for hydraulic resonance of the pressure sensing system is presented. For the control valve investigated, air entrainment, length and diameter of the resonator neck, and valve mass produced the greatest shift in resonant frequency. Experimental work was conducted on the hydraulic system so that the resonance levels and frequencies could be measured and the accuracy of the theory verified. The results obtained make it possible to evaluate what changes to any of the variables considered would be most effective in driving the second harmonic frequency above the operating range.

  12. Soil Structure and Saturated Hydraulic Conductivity

    Science.gov (United States)

    Houskova, B.; Nagy, V.

    The role of soil structure on saturated hydraulic conductivity changes is studied in plough layers of texturally different soils. Three localities in western part of Slovakia in Zitny ostrov (Corn Island) were under investigation: locality Kalinkovo with light Calcaric Fluvisol (FAO 1970), Macov with medium heavy Calcari-mollic Fluvisol and Jurova with heavy Calcari-mollic Fluvisol. Soil structure was determined in dry as well as wet state and in size of macro and micro aggregates. Saturated hydraulic conductivity was measured by the help of double ring method. During the period of ring filling the soil surface was protected against aggregates damage by falling water drops. Spatial and temporal variability of studied parameters was evaluated. Cultivated crops were ensilage maize at medium heavy and heavy soil and colza at light soil. Textural composition of soil and actual water content at the beginning of measurement are one of major factor affecting aggregate stability and consequently also saturated hydraulic conductivity.

  13. Universal asymptotic umbrella for hydraulic fracture modeling

    CERN Document Server

    Linkov, Aleksandr M

    2014-01-01

    The paper presents universal asymptotic solution needed for efficient modeling of hydraulic fractures. We show that when neglecting the lag, there is universal asymptotic equation for the near-front opening. It appears that apart from the mechanical properties of fluid and rock, the asymptotic opening depends merely on the local speed of fracture propagation. This implies that, on one hand, the global problem is ill-posed, when trying to solve it as a boundary value problem under a fixed position of the front. On the other hand, when properly used, the universal asymptotics drastically facilitates solving hydraulic fracture problems (both analytically and numerically). We derive simple universal asymptotics and comment on their employment for efficient numerical simulation of hydraulic fractures, in particular, by well-established Level Set and Fast Marching Methods.

  14. Self-potential observations during hydraulic fracturing

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Jeffrey R.; Glaser, Steven D.

    2007-09-13

    The self-potential (SP) response during hydraulic fracturing of intact Sierra granite was investigated in the laboratory. Excellent correlation of pressure drop and SP suggests that the SP response is created primarily by electrokinetic coupling. For low pressures, the variation of SP with pressure drop is linear, indicating a constant coupling coefficient (Cc) of -200 mV/MPa. However for pressure drops >2 MPa, the magnitude of the Cc increases by 80% in an exponential trend. This increasing Cc is related to increasing permeability at high pore pressures caused by dilatancy of micro-cracks, and is explained by a decrease in the hydraulic tortuosity. Resistivity measurements reveal a decrease of 2% prior to hydraulic fracturing and a decrease of {approx}35% after fracturing. An asymmetric spatial SP response created by injectate diffusion into dilatant zones is observed prior to hydraulic fracturing, and in most cases this SP variation revealed the impending crack geometry seconds before failure. At rupture, injectate rushes into the new fracture area where the zeta potential is different than in the rock porosity, and an anomalous SP spike is observed. After fracturing, the spatial SP distribution reveals the direction of fracture propagation. Finally, during tensile cracking in a point load device with no water flow, a SP spike is observed that is caused by contact electrification. However, the time constant of this event is much less than that for transients observed during hydraulic fracturing, suggesting that SP created solely from material fracture does not contribute to the SP response during hydraulic fracturing.

  15. Measurement and modeling of unsaturated hydraulic conductivity

    Science.gov (United States)

    Perkins, Kim S.; Elango, Lakshmanan

    2011-01-01

    The unsaturated zone plays an extremely important hydrologic role that influences water quality and quantity, ecosystem function and health, the connection between atmospheric and terrestrial processes, nutrient cycling, soil development, and natural hazards such as flooding and landslides. Unsaturated hydraulic conductivity is one of the main properties considered to govern flow; however it is very difficult to measure accurately. Knowledge of the highly nonlinear relationship between unsaturated hydraulic conductivity (K) and volumetric water content is required for widely-used models of water flow and solute transport processes in the unsaturated zone. Measurement of unsaturated hydraulic conductivity of sediments is costly and time consuming, therefore use of models that estimate this property from more easily measured bulk-physical properties is common. In hydrologic studies, calculations based on property-transfer models informed by hydraulic property databases are often used in lieu of measured data from the site of interest. Reliance on database-informed predicted values with the use of neural networks has become increasingly common. Hydraulic properties predicted using databases may be adequate in some applications, but not others. This chapter will discuss, by way of examples, various techniques used to measure and model hydraulic conductivity as a function of water content, K. The parameters that describe the K curve obtained by different methods are used directly in Richards’ equation-based numerical models, which have some degree of sensitivity to those parameters. This chapter will explore the complications of using laboratory measured or estimated properties for field scale investigations to shed light on how adequately the processes are represented. Additionally, some more recent concepts for representing unsaturated-zone flow processes will be discussed.

  16. On the Hydraulics of Flowing Horizontal Wells

    Science.gov (United States)

    Bian, A.; Zhan, H.

    2003-12-01

    A flowing horizontal well is a special type of horizontal well that does not have pumping/injecting facility. The discharge rate of a flowing horizontal well is controlled by the hydraulic gradient between the aquifer and the well and it generally varies with time if the hydraulic head of the aquifer is transient. This type of well has been used in landslide control, mining dewatering, water table control, underground water transportation through a horizontal tunnel, agricultural water drainage, and other applications. Flowing horizontal wells have quite different hydrodynamic characteristics from horizontal wells with fixed pumping or injecting rates because their discharge rates are functions of the aquifer hydraulic heads (Zhan et al, 2001; Zhan and Zlotnik, 2002). Hydraulics of flowing horizontal wells have rarely been studied although the hydraulics of flowing vertical wells have been extensively investigated before. The purpose of this paper is to obtain analytical solutions of groundwater flow to a flowing horizontal-well in a confined aquifer, in a water table aquifer without precipitation, and in a water table aquifer with precipitation. The functions of the flowing horizontal well discharge rates versus time will be obtained under above mentioned different aquifer conditions. The relationships of the aquifer hydraulic heads versus the discharge rates of the well will be investigated. The rate of water table decline due to the dewatering of the well will also be computed, and this solution is particularly useful for landslide control and mining dewatering. The theoretical solutions will be compared with results of experiments that will be conducted in the hydrological laboratory at Texas A&M University. Reference: Zhan, H., Wang, L.V., and Park, E, On the horizontal well pumping tests in the anisotropic confined aquifers, J. hydrol., 252, 37-50, 2001. Zhan, H., and Zlotnik, V. A., Groundwater flow to a horizontal or slanted well in an unconfined aquifer

  17. Experimental determination of optimal clamping torque for AB-PEM Fuel cell

    Directory of Open Access Journals (Sweden)

    Noor Ul Hassan

    2016-04-01

    Full Text Available Polymer electrolyte Membrane (PEM fuel cell is an electrochemical device producing electricity by the reaction of hydrogen and oxygen without combustion. PEM fuel cell stack is provided with an appropriate clamping torque to prevent leakage of reactant gases and to minimize the contact resistance between gas diffusion media (GDL and bipolar plates. GDL porous structure and gas permeability is directly affected by the compaction pressure which, consequently, drastically change the fuel cell performance. Various efforts were made to determine the optimal compaction pressure and pressure distributions through simulations and experimentation. Lower compaction pressure results in increase of contact resistance and also chances of leakage. On the other hand, higher compaction pressure decreases the contact resistance but also narrows down the diffusion path for mass transfer from gas channels to the catalyst layers, consequently, lowering cell performance. The optimal cell performance is related to the gasket thickness and compression pressure on GDL. Every stack has a unique assembly pressure due to differences in fuel cell components material and stack design. Therefore, there is still need to determine the optimal torque value for getting the optimal cell performance. This study has been carried out in continuation of deve­lopment of Air breathing PEM fuel cell for small Unmanned Aerial Vehicle (UAV application. Compaction pressure at minimum contact resistance was determined and clamping torque value was calcu­la­ted accordingly. Single cell performance tests were performed at five different clamping torque values i.e 0.5, 1.0, 1.5, 2.0 and 2.5 N m, for achieving optimal cell per­formance. Clamping pressure distribution tests were also performed at these torque values to verify uniform pressure distribution at optimal torque value. Experimental and theoretical results were compared for making inferences about optimal cell perfor­man­ce. A

  18. Voltage- and space-clamp errors associated with the measurement of electrotonically remote synaptic events.

    Science.gov (United States)

    Spruston, N; Jaffe, D B; Williams, S H; Johnston, D

    1993-08-01

    1. The voltage- and space-clamp errors associated with the use of a somatic electrode to measure current from dendritic synapses are evaluated using both equivalent-cylinder and morphologically realistic models of neuronal dendritic trees. 2. As a first step toward understanding the properties of synaptic current distortion under voltage-clamp conditions, the attenuation of step and sinusoidal voltage changes are evaluated in equivalent cylinder models. Demonstration of the frequency-dependent attenuation of voltage in the cable is then used as a framework for understanding the distortion of synaptic currents generated at sites remote from the somatic recording electrode and measured in the voltage-clamp recording configuration. 3. Increases in specific membrane resistivity (Rm) are shown to reduce steady-state voltage attenuation, while producing only minimal reduction in attenuation of transient voltage changes. Experimental manipulations that increase Rm therefore improve the accuracy of estimates of reversal potential for electrotonically remote synapses, but do not significantly reduce the attenuation of peak current. In addition, increases in Rm have the effect of slowing the kinetics of poorly clamped synaptic currents. 4. The effects of the magnitude of the synaptic conductance and its kinetics on the measured synaptic currents are also examined and discussed. The error in estimating parameters from measured synaptic currents is greatest for synapses with fast kinetics and large conductances. 5. A morphologically realistic model of a CA3 pyramidal neuron is used to demonstrate the generality of the conclusions derived from equivalent cylinder models. The realistic model is also used to fit synaptic currents generated by stimulation of mossy fiber (MF) and commissural/associational (C/A) inputs to CA3 neurons and to estimate the amount of distortion of these measured currents. 6. Anatomic data from the CA3 pyramidal neuron model are used to construct a

  19. Thermal Hydraulic Stability in a Coaxial Thermosyphon

    Institute of Scientific and Technical Information of China (English)

    YANG Jianhui; LU Wenqiang; LI Qing; LI Qiang; ZHOU Yuan

    2005-01-01

    The heat transfer and thermal hydraulic stability in a two-phase thermosyphon with coaxial riser and down-comer has been experimentally investigated and theoretically analyzed to facilitate its application in cold neutron source. The flow in a coaxial thermosyphon was studied experimentally for a variety of heating rates, transfer tube lengths, charge capacities, and area ratios. A numerical analysis of the hydraulic balance between the driving pressure head and the resistance loss has also been performed. The results show that the presented coaxial thermosyphon has dynamic performance advantages relative to natural circulation in a boiling water reactor.

  20. Large-eddy simulation in hydraulics

    CERN Document Server

    Rodi, Wolfgang

    2013-01-01

    Complex turbulence phenomena are of great practical importance in hydraulics, including environmental flows, and require advanced methods for their successful computation. The Large Eddy Simulation (LES), in which the larger-scale turbulent motion is directly resolved and only the small-scale motion is modelled, is particularly suited for complex situations with dominant large-scale structures and unsteadiness. Due to the increasing computer power, LES is generally used more and more in Computational Fluid Dynamics. Also in hydraulics, it offers great potential, especially for near-field probl

  1. Mineral resource of the month: hydraulic cement

    Science.gov (United States)

    van Oss, Hendrik G.

    2012-01-01

    Hydraulic cements are the binders in concrete and most mortars and stuccos. Concrete, particularly the reinforced variety, is the most versatile of all construction materials, and most of the hydraulic cement produced worldwide is portland cement or similar cements that have portland cement as a basis, such as blended cements and masonry cements. Cement typically makes up less than 15 percent of the concrete mix; most of the rest is aggregates. Not counting the weight of reinforcing media, 1 ton of cement will typically yield about 8 tons of concrete.

  2. Conformational analysis of processivity clamps in solution demonstrates that tertiary structure does not correlate with protein dynamics.

    Science.gov (United States)

    Fang, Jing; Nevin, Philip; Kairys, Visvaldas; Venclovas, Ceslovas; Engen, John R; Beuning, Penny J

    2014-04-08

    The relationship between protein sequence, structure, and dynamics has been elusive. Here, we report a comprehensive analysis using an in-solution experimental approach to study how the conservation of tertiary structure correlates with protein dynamics. Hydrogen exchange measurements of eight processivity clamp proteins from different species revealed that, despite highly similar three-dimensional structures, clamp proteins display a wide range of dynamic behavior. Differences were apparent both for structurally similar domains within proteins and for corresponding domains of different proteins. Several of the clamps contained regions that underwent local unfolding with different half-lives. We also observed a conserved pattern of alternating dynamics of the α helices lining the inner pore of the clamps as well as a correlation between dynamics and the number of salt bridges in these α helices. Our observations reveal that tertiary structure and dynamics are not directly correlated and that primary structure plays an important role in dynamics.

  3. Simulation Based Performance analysis of Active Clamp DHB ZVZCS Bidirectional DC-DC converter for Low Power Applications

    Directory of Open Access Journals (Sweden)

    V.V.Subrahmanya Kumar Bhajana

    2012-06-01

    Full Text Available A novel active clamp dual half bridge DC/DC converter with bidirectional power flow is proposed in this paper and comparative analysis between active clamp DHB ZVZCS and ZVS-ZCS bidirectional DC-DC converter topologies is also presented. By adding active clamping circuits to both bridges, zero voltage and zero current switching are achieved to improve the performance of the bidirectional DC/DC converter. The principle of operation is analyzed and simulated. With the proposed active clamp ZVZCS concept, the MATLAB simulation results of the applications of the fuel cell and battery have been obtained and compared with those of ZVS-ZCS bidirectional converter. The simulation results of proposed converter is compared with the ZVS-ZCS bidirectional DC-DC converter, efficiency, switching losses are the key parameters compared.

  4. Tools for electrophysiology labs: a C coded dynamic-clamp on DSP board (aC/DC).

    OpenAIRE

    Boussa, Sofiane; Pasquier, Jennifer; Leboulenger, Francois; Le Foll, Frank; Faure, Alain

    2008-01-01

    ISBN : 978-2-9532965-0-1; Dynamic-clamp represents an archetypal interdisciplinary approach in the field of computational neuroscience because it aims at establishing a dialog in real time between i) a numerical model and a spiking cell and ii) between neurobiologists and computer programmers. In this paper, we present a relative simple hardware solution for an efficient dynamic-clamp application. The prototype has been built around a DSP board (dsPIC 33F, Microchip INC). Our results demonstr...

  5. Effect of timing of umbilical cord clamping on iron status in Mexican infants: a randomised controlled trial.

    Science.gov (United States)

    Chaparro, Camila M; Neufeld, Lynnette M; Tena Alavez, Gilberto; Eguia-Líz Cedillo, Raúl; Dewey, Kathryn G

    2006-06-17

    Delayed clamping of the umbilical cord increases the infant's iron endowment at birth and haemoglobin concentration at 2 months of age. We aimed to assess whether a 2-minute delay in the clamping of the umbilical cord of normal-weight, full-term infants improved iron and haematological status up to 6 months of age. 476 mother-infant pairs were recruited at a large obstetrics hospital in Mexico City, Mexico, randomly assigned to delayed clamping (2 min after delivery of the infant's shoulders) or early clamping (around 10 s after delivery), and followed up until 6 months postpartum. Primary outcomes were infant haematological status and iron status at 6 months of age, and analysis was by intention-to-treat. This study is registered with ClinicalTrials.gov, number NCT00298051. 358 (75%) mother-infant pairs completed the trial. At 6 months of age, infants who had delayed clamping had significantly higher mean corpuscular volume (81.0 fL vs 79.5 fL 95% CI -2.5 to -0.6, p=0.001), ferritin (50.7 mug/L vs 34.4 mug/L 95% CI -30.7 to -1.9, p=0.0002), and total body iron. The effect of delayed clamping was significantly greater for infants born to mothers with low ferritin at delivery, breastfed infants not receiving iron-fortified milk or formula, and infants born with birthweight between 2500 g and 3000 g. A cord clamping delay of 2 minutes increased 6-month iron stores by about 27-47 mg. Delay in cord clamping of 2 minutes could help prevent iron deficiency from developing before 6 months of age, when iron-fortified complementary foods could be introduced.

  6. Mechatronic Hydraulic Drive with Regulator, Based on Artificial Neural Network

    Science.gov (United States)

    Burennikov, Y.; Kozlov, L.; Pyliavets, V.; Piontkevych, O.

    2017-06-01

    Mechatronic hydraulic drives, based on variable pump, proportional hydraulics and controllers find wide application in technological machines and testing equipment. Mechatronic hydraulic drives provide necessary parameters of actuating elements motion with the possibility of their correction in case of external loads change. This enables to improve the quality of working operations, increase the capacity of machines. The scheme of mechatronic hydraulic drive, based on the pump, hydraulic cylinder, proportional valve with electrohydraulic control and programmable controller is suggested. Algorithm for the control of mechatronic hydraulic drive to provide necessary pressure change law in hydraulic cylinder is developed. For the realization of control algorithm in the controller artificial neural networks are used. Mathematical model of mechatronic hydraulic drive, enabling to create the training base for adjustment of artificial neural networks of the regulator is developed.

  7. DCS Hydraulics Submittal, Valencia County, New Mexico, USA

    Data.gov (United States)

    Federal Emergency Management Agency, Department of Homeland Security — Hydraulics data includes spatial datasets and data tables necessary for documenting the hydraulic procedures for computing flood elevations for a flood insurance...

  8. Chapter 12. Pure Tap Water Hydraulic Systems and Applications

    DEFF Research Database (Denmark)

    Conrad, Finn; Adelstorp, Anders

    1997-01-01

    Presentation of developed a modern pure tap water hydraulic components (Nessie), systems and industrial applications.......Presentation of developed a modern pure tap water hydraulic components (Nessie), systems and industrial applications....

  9. A tensor approach to the estimation of hydraulic conductivities in ...

    African Journals Online (AJOL)

    2006-07-03

    Jul 3, 2006 ... The HC values computed from the data measured on the weathered or ... Keywords: hydraulic conductivity tensor, roughness, combined stress, hydraulic aperture, Table Mountain ... the anisotropic nature of studied media.

  10. A conserved physical and functional interaction between the cell cycle checkpoint clamp loader and DNA ligase I of eukaryotes.

    Science.gov (United States)

    Song, Wei; Levin, David S; Varkey, Johnson; Post, Sean; Bermudez, Vladimir P; Hurwitz, Jerard; Tomkinson, Alan E

    2007-08-03

    DNA ligase I joins Okazaki fragments during DNA replication and completes certain excision repair pathways. The participation of DNA ligase I in these transactions is directed by physical and functional interactions with proliferating cell nuclear antigen, a DNA sliding clamp, and, replication factor C (RFC), the clamp loader. Here we show that DNA ligase I also interacts with the hRad17 subunit of the hRad17-RFC cell cycle checkpoint clamp loader, and with each of the subunits of its DNA sliding clamp, the heterotrimeric hRad9-hRad1-hHus1 complex. In contrast to the inhibitory effect of RFC, hRad17-RFC stimulates joining by DNA ligase I. Similar results were obtained with the homologous Saccharomyces cerevisiae proteins indicating that the interaction between the replicative DNA ligase and checkpoint clamp is conserved in eukaryotes. Notably, we show that hRad17 preferentially interacts with and specifically stimulates dephosphorylated DNA ligase I. Moreover, there is an increased association between DNA ligase I and hRad17 in S phase following DNA damage and replication blockage that occurs concomitantly with DNA damage-induced dephosphorylation of chromatin-associated DNA ligase I. Thus, our results suggest that the in vivo interaction between DNA ligase I and the checkpoint clamp loader is regulated by post-translational modification of DNA ligase I.

  11. The use of asphalt in hydraulic engineering

    NARCIS (Netherlands)

    Van de Velde, P.A.; Ebbens, E.H.; Van Herpen, J.A.

    1985-01-01

    Asphalt products have been used in the Netherlands in hydraulic engineering for a long time on a large scale, especially after the great disaster in 1953 when a large part of western Holland was flooded by the sea. After the disaster a great number of dikes had to be repaired very quickly and this w

  12. Elevator and hydraulics; Elevator to yuatsu

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, I. [Hitachi, Ltd., Tokyo (Japan)

    1994-07-15

    A hydraulic type elevator is installed in relatively lower buildings as compared with a rope type elevator, but the ratio in the number of installation of the former elevator is increasing. This paper explains from its construction and features to especially various control systems for the riding comfort and safety. A direct push-up system with hydraulic jacks arranged beneath a car, and an indirect push-up system that has hydraulic jacks arranged on flank of a car and transmits the movement of a plunger via a rope are available. The latter system eliminates the need of large holes to embed hydraulic jacks. While the speed is controlled by controlling flow rates of high-pressure oil, the speed, position, acceleration and even time differential calculus of the acceleration must be controlled severely. The system uses two-step control for the through-speed and the landing speed. Different systems that have been realized may include compensation for temperatures in flow rate control valves, load pressures, and oil viscosity, from learning control to fuzzy control for psychological effects, or control of inverters in motors. 13 refs., 12 figs., 1 tab.

  13. Hydraulic adjustment of Scots pine across Europe

    NARCIS (Netherlands)

    Martínez-Vilalta, J.; Cochard, H.; Mencuccini, M.; Sterck, F.J.; Herrero, A.; Korhonen, J.F.J.; Llorens, P.; Nikinmaa, E.; Nolè, A.; Poyatos, R.; Ripullone, F.; Sass-Klaassen, U.; Zweifel, R.

    2009-01-01

    The variability of branch-level hydraulic properties was assessed across 12 Scots pine populations covering a wide range of environmental conditions, including some of the southernmost populations of the species. The aims were to relate this variability to differences in climate, and to study the po

  14. Influence of tray hydraulics on tray column

    NARCIS (Netherlands)

    Betlem, Bernardus H.L.; Rijnsdorp, J.E.; Rijnsdorp, J.E.; Azink, R.F.

    1998-01-01

    To column control, in contrast to column design, tray hold-up and dependencies of tray hold-up on the operating conditions play an important role. The essence of this article is the development of an improved model of tray hydraulics over a broad operating range and its experimental validation by

  15. Design of a hydraulic bending machine

    Science.gov (United States)

    Steven G. Hankel; Marshall Begel

    2004-01-01

    To keep pace with customer demands while phasing out old and unserviceable test equipment, the staff of the Engineering Mechanics Laboratory (EML) at the USDA Forest Service, Forest Products Laboratory, designed and assembled a hydraulic bending test machine. The EML built this machine to test dimension lumber, nominal 2 in. thick and up to 12 in. deep, at spans up to...

  16. Sustainable hydraulic engineering through building with nature

    NARCIS (Netherlands)

    Vriend, de H.J.; Koningsveld, van M.; Aarninkhof, S.G.J.; Vries, de M.B.; Baptist, M.J.

    2015-01-01

    Hydraulic engineering infrastructures are of concern to many people and are likely to interfere with the environment. Moreover, they are supposed to keep on functioning for many years. In times of rapid societal and environmental change this implies that sustainability and adaptability are important

  17. The use of asphalt in hydraulic engineering

    NARCIS (Netherlands)

    Van de Velde, P.A.; Ebbens, E.H.; Van Herpen, J.A.

    1985-01-01

    Asphalt products have been used in the Netherlands in hydraulic engineering for a long time on a large scale, especially after the great disaster in 1953 when a large part of western Holland was flooded by the sea. After the disaster a great number of dikes had to be repaired very quickly and this w

  18. International Institute for Hydraulic and Environmental Engineering

    Science.gov (United States)

    Mostertman, L. J.

    1977-01-01

    Describes the activities of the International Institute for Hydraulic and Environmental Engineering (IHE), whose primary function is the promotion of the better use of water resources as a vehicle of development by the transfer of knowledge and experience. (Author/RK)

  19. Digital hydraulic valving system. [design and development

    Science.gov (United States)

    1973-01-01

    The design and development are reported of a digital hydraulic valving system that would accept direct digital inputs. Topics include: summary of contractual accomplishments, design and function description, valve parameters and calculations, conclusions, and recommendations. The electrical control circuit operating procedure is outlined in an appendix.

  20. Sustainable hydraulic engineering through building with nature

    NARCIS (Netherlands)

    Vriend, de H.J.; Koningsveld, van M.; Aarninkhof, S.G.J.; Vries, de M.B.; Baptist, M.J.

    2015-01-01

    Hydraulic engineering infrastructures are of concern to many people and are likely to interfere with the environment. Moreover, they are supposed to keep on functioning for many years. In times of rapid societal and environmental change this implies that sustainability and adaptability are important

  1. Reactive barriers: hydraulic performance and design enhancements.

    Science.gov (United States)

    Painter, B D M

    2004-01-01

    The remediation of contaminated ground water is a multibillion-dollar global industry. Permeable reactive barriers (PRBs) are one of the leading technologies being developed in the search for alternatives to the pump-and-treat method. Improving the hydraulic performance of these PRBs is an important part of maximizing their potential to the industry. Optimization of the hydraulic performance of a PRB can be defined in terms of finding the balance between capture, residence time, and PRB longevity that produces a minimum-cost acceptable design. Three-dimensional particle tracking was used to estimate capture zone and residence time distributions. Volumetric flow analysis was used for estimation of flow distribution across a PRB and in the identification of flow regimes that may affect the permeability or reactivity of portions of the PRB over time. Capture zone measurements extended below the base of partially penetrating PRBs and were measured upgradient from the portion of aquifer influenced by PRB emplacement. Hydraulic performance analysis of standard PRB designs confirmed previously presented research that identified the potential for significant variation in residence time and capture zone. These variations can result in the need to oversize the PRB to ensure that downgradient contaminant concentrations do not exceed imposed standards. The most useful PRB design enhancements for controlling residence time and capture variation were found to be customized downgradient gate faces, velocity equalization walls, deeper emplacement of the funnel than the gate, and careful manipulation of the hydraulic conductivity ratio between the gate and the aquifer.

  2. SITMILARITY LAW FOR HYDRAULIC DISTORTED MODEL

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    Newton's general similarity criterion was applied to the distorted model. The results for the similarities of gravity force, drag force and pressure force are identical with those derived from relevant differential equations of fluid flow. And the selected limits of the distorted ratio were studied and the simulation of roughness coefficient of distorted model was conducted by means of hydraulic test.

  3. Separation and pattern formation in hydraulic jumps

    DEFF Research Database (Denmark)

    Bohr, Tomas; Ellegaard, C.; Hansen, A. Espe;

    1998-01-01

    We present theory and experiments on the circular hydraulic jump in the stationary regime. The theory can handle the situation in which the fluid flows over an edge far away from the jump. In the experiments the external height is controlled, and a series of transitions in the flow structure appe...

  4. HYDRAULIC CONDUCTIVITY OF THREE GEOSYNTHETIC CLAY LINERS

    Science.gov (United States)

    The hydraulic conductivity of three 2.9 m2 (32 sq ft) geosynthetic clay liners (GCLs) was measured. Tests were performed on individual sheets of the GCLs, on overlapped pieces of GCLs, and on composite liners consisting of a punctured geomembrane overlying a GCL. Hyd...

  5. Towards Autonomous Control of Hydraulic Actuator Systems

    DEFF Research Database (Denmark)

    Hansen, Poul Erik; Conrad, Finn

    1998-01-01

    Presentation of new developed control algorithms to increase autonomy and intelligence of hydraulic control systems. A refinement of relaytuning method is used to determine the control parameters of a lag/lead controller and a poleplacement controller. Further, a fail-safe function is developed t...

  6. Power management in hydraulically actuated mobile equipment

    DEFF Research Database (Denmark)

    Pedersen, Henrik Clemmensen; Andersen, Torben Ole; Hansen, Michael Rygaard

    2008-01-01

    The focus of the current paper is on the control of hydraulic systems when utilizing the advances that electronic control may bring with regard to power management, prioritized flow sharing and anti-stall, arising from being able to control both pump, valves and engine electronically. A simple mo...

  7. Dentin permeability: determinants of hydraulic conductance.

    Science.gov (United States)

    Reeder, O W; Walton, R E; Livingston, M J; Pashley, D H

    1978-02-01

    A technique is described which permits measurements of the ease with which fluid permeates dentin. This value, the hydraulic conductance of dentin, increased as surface area increases and/or as dentin thickness decreases. It increased 32-fold when dentin was acid etched due to removal of surface debris occluding the tubules.

  8. Analysis of Innovative Design of Energy Efficient Hydraulic Actuators

    OpenAIRE

    M Osman Abdalla

    2013-01-01

    Hydraulic cylinder actuators are used extensively in industrial, construction and agricultural works. The small sized outlet ports of the cylinders resist the flow of discharged oil; and as a result the piston motion is slowed down. This causes a lot of heat generation and energy loss within the actuators. The study investigates and analyzes the possibilities of reducing the hydraulic resistance and increasing efficiency of the hydraulic actuator. Conventional hydraulic cylinders are simulate...

  9. DISCONTINUOUS FLOW OF TURBID DENSITY CURRENTS Ⅱ. INTERNAL HYDRAULIC JUMP

    Institute of Scientific and Technical Information of China (English)

    Jiahua FAN

    2005-01-01

    Traveling and stationary internal hydraulic jumps in density currents with positive or negative entrainment coefficients were analyzed based on simple assumptions. An expression of internal hydraulic jumps with entrainment coefficients was derived. Experimental data, published in literature, of stationary internal hydraulic jumps in turbid, thermal and saline density currents including measured values of water entrainment were used to compare with theory. Comparison was also made of traveling internal hydraulic jumps between measured data and theory.

  10. OPTIMAL HYDRAULIC DESIGN AND CAD APPLICATIONS OF AXIAL FLOW HYDRAULIC TURBINE'S RUNNER

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    A method of the optimal hydraulic design and CAD application of runner blades of axial-flow hydraulic turbines are discussed on the basis of optimization principle and CAD technique in this paper. Based on the theory of fluid dynamics, the blade′s main geometrical parameter, working parameters and performances index of the blades and the relationship between them are analysed, and the mathematical model of optimal hydraulic design of axial-flow runners has been established. Through nonlinear programming, the problems can be solved. By making use of the calculation geometry and computer graphics, the distribution method of the singular points, and an CAD applied software, an optimal hydraulic design are presented.

  11. Hydraulic Bureaucracy in a Modern Hydraulic Society – Strategic Group Formation in the Mekong Delta, Vietnam

    Directory of Open Access Journals (Sweden)

    Hans-Dieter Evers

    2009-10-01

    Among these strategic groups, the hydraulic bureaucracy and hydraulic construction business are the most crucial in terms of the specific role they play in the hydraulic landscape of the Mekong delta. Both groups exert considerable influence on water resources management and strive for the same resources, namely public funds (including Overseas Development Aid that is directed to hydraulic infrastructure development. This paper illustrates how both groups have emerged due to the growing need for water resources management in the delta and how they have set up alliances for mutually sharing resources in the long run. Furthermore, it is shown how both groups have adapted their resource-oriented strategies and actions to respond to the changes in the economic and political environment in Vietnam’s recent history.

  12. Hydraulic power take-off for wave energy systems

    DEFF Research Database (Denmark)

    Christensen, Georg Kronborg

    2001-01-01

    Investigation and laboratory experiments with a hydraulic power conversion system for converting forces from a 2.5m diamter float to extract energy from seawaves. The test rig consists of a hydraulic wave simulator and a hydraulic point absorber. The absorber converts the incomming forces...

  13. 21 CFR 880.5110 - Hydraulic adjustable hospital bed.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hydraulic adjustable hospital bed. 880.5110... (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use Therapeutic Devices § 880.5110 Hydraulic adjustable hospital bed. (a) Identification. A hydraulic adjustable...

  14. 14 CFR 33.72 - Hydraulic actuating systems.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Hydraulic actuating systems. 33.72 Section... AIRWORTHINESS STANDARDS: AIRCRAFT ENGINES Design and Construction; Turbine Aircraft Engines § 33.72 Hydraulic actuating systems. Each hydraulic actuating system must function properly under all conditions in which...

  15. 7 CFR 2902.10 - Mobile equipment hydraulic fluids.

    Science.gov (United States)

    2010-01-01

    ... Comprehensive Procurement Guideline, 40 CFR 247.11. ... 7 Agriculture 15 2010-01-01 2010-01-01 false Mobile equipment hydraulic fluids. 2902.10 Section... PROCUREMENT Designated Items § 2902.10 Mobile equipment hydraulic fluids. (a) Definition. Hydraulic...

  16. Comparison of four methods to assess hydraulic conductivity

    Energy Technology Data Exchange (ETDEWEB)

    Benson, C.H. [Univ. of Wisconsin, Madison, WI (United States). Dept. of Civil and Environmental Engineering; Gunter, J.A. [Gunter (John A.), Round Rock, TX (United States); Boutwell, G.P. [STE, Inc., Baton Rouge, LA (United States); Trautwein, S.J. [Trautwein Soil Testing Equipment Co., Houston, TX (United States); Berzanskis, P.H. [Hoechst-Celanese, Inc., Pampa, TX (United States)

    1997-10-01

    A hydraulic conductivity assessment that was conducted on four test pads constructed to the same specifications with soil from the same source by four different contractors is described. The test pads had distinctly different field hydraulic conductivities, even though they were constructed with similar soil, to similar compaction conditions, and with similar machinery. Adequate hydration time was key in achieving low field hydraulic conductivity. More extensive processing was another factor responsible for low field hydraulic conductivity. Four different test methods were used to assess the hydraulic conductivity of each test pad: (1) sealed double-ring infiltrometers (SDRIs); (2) two-stage borehole permeameters; (3) laboratory hydraulic conductivity tests on large block specimens; and (4) laboratory hydraulic conductivity tests on small specimens collected in thin-wall sampling tubes. The tests were conducted independently by each of the writers. After the tests were completed, the results were submitted and compared. Analysis of the test results show that the three large-scale test methods generally yield similar hydraulic conductivities. For two of the test pads, however, the hydraulic conductivities of the specimens collected in sampling tubes were significantly lower than the field hydraulic conductivities. Both of these test pads had high field hydraulic conductivity. Thus, there is little value in using small specimens to assess field hydraulic conductivity.

  17. 23 CFR 650.111 - Location hydraulic studies.

    Science.gov (United States)

    2010-04-01

    ... 23 Highways 1 2010-04-01 2010-04-01 false Location hydraulic studies. 650.111 Section 650.111 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION ENGINEERING AND TRAFFIC OPERATIONS BRIDGES, STRUCTURES, AND HYDRAULICS Location and Hydraulic Design of Encroachments on Flood Plains §...

  18. Transition from fetal to neonatal circulation: Modeling the effect of umbilical cord clamping.

    Science.gov (United States)

    Yigit, Mehmet B; Kowalski, William J; Hutchon, David J R; Pekkan, Kerem

    2015-06-25

    Hemodynamics of the fetal to neonatal transition are orchestrated through complex physiological changes and results in cardiovascular adaptation to the adult biventricular circulation. Clinical practice during this critical period can influence vital organ physiology for normal newborns, premature babies and congenital heart defect patients. Particularly, the timing of the cord clamping procedure, immediate (ICC) vs. delayed cord clamping (DCC), is hypothesized to be an important factor for the transitory fetal hemodynamics. The clinical need for a quantitative understanding of this physiology motivated the development of a lumped parameter model (LPM) of the fetal cardio-respiratory system covering the late-gestation to neonatal period. The LPM was validated with in vivo clinical data and then used to predict the effects of cord clamping procedures on hemodynamics and vital gases. Clinical time-dependent resistance functions to simulate the vascular changes were introduced. For DCC, placental transfusion (31.3 ml) increased neonatal blood volume by 11.7%. This increased blood volume is reflected in an increase in preload pressures by ~20% compared to ICC, which in turn increased the cardiac output (CO) by 20% (COICC=993 ml/min; CODCC=1197 ml/min). Our model accurately predicted dynamic flow patterns in vivo. DCC was shown to maintain oxygenation if the onset of pulmonary respiration was delayed or impaired. On the other hand, a significant 25% decrease in oxygen saturations was observed when applying ICC under the same physiological conditions. We conclude that DCC has a significant impact on newborn hemodynamics, mainly because of the improved blood volume and the sustained placental respiration. Copyright © 2015. Published by Elsevier Ltd.

  19. Timing of umbilical cord clamping among infants born at 22 through 27 weeks' gestation.

    Science.gov (United States)

    Backes, C H; Huang, H; Iams, J D; Bauer, J A; Giannone, P J

    2016-01-01

    To investigate the safety, feasibility and efficacy of delayed cord clamping (DCC) compared with immediate cord clamping (ICC) at delivery among infants born at 22 to 27 weeks' gestation. This was a pilot, randomized, controlled trial in which women in labor with singleton pregnancies at 22 to 27 weeks' gestation were randomly assigned to ICC (cord clamped at 5 to 10 s) or DCC (30 to 45 s). Forty mother-infant pairs were randomized. Infants in the ICC and DCC groups had mean gestational ages (GA) of 24.6 and 24.4 weeks, respectively. No differences were observed between the groups across all available safety measures, although infants in the DCC group had higher admission temperatures than infants in the ICC group (97.4 vs. 96.2 °F, P=0.04). During the first 24 h of life, blood pressures were lower in the ICC group than in the DCC group (P<0.05), despite a threefold greater incidence of treatment for hypotension (45% vs. 12%, P<0.01). Infants in the ICC group had increased numbers of red blood transfusions (in first 28 days of life) than infants in DCC group (4.1±3.9 vs. 2.8±2.2, P=0.04). Among infants born at an average GA of 24 weeks', DCC appears safe, logistically feasible, and offers hematological and circulatory advantages compared with ICC. A more comprehensive appraisal of this practice is needed.

  20. The Analysis of Clamping Mechanism Theory and the Application Design of Tobacco Leaves'Clamping Tool%夹紧机构的理论分析及烘烤烟叶夹的应用设计

    Institute of Scientific and Technical Information of China (English)

    徐远龙; 孙有祥

    2011-01-01

    In view of the complicated manual skill of the tobacco leaf weaving, the study and design of a kind tool clamping tobacco leaf is proposed by our actual investigation; According to the predetermined function demand and the available clamping mechanism, the principle of the clamping tool is studied out, the structural design scheme of the clamping tool is worked out and the clamping tool is made by the theory analysis of mechanism design and the study of clamping mechanism. The clamping tool tested by the surveyor is good in use, which is welcome to use by the peasants and the economy benefit of the market can be achieved highly.%通过对烟叶烘烤生产工艺的实际调研,针对手工繁杂的编烟技术,提出了研究设计一种烘烤烟叶夹持工具;针对烘烤烟叶夹的预定功能要求,参考现有的实用夹紧机构,通过对机械产品机构设计的理论分析和夹紧机构的力学研究,确定了夹紧烟叶的力学原理,提出了烘烤烟叶夹的结构设计方案,设计制造出烘烤烟叶夹;该烘烤烟叶夹通过了产品的质量检测,使用效果良好,烟农用户普遍接受使用,预计有较高的市场经济效益.

  1. The Elg1 Clamp Loader Plays a Role in Sister Chromatid Cohesion

    OpenAIRE

    Oren Parnas; Adi Zipin-Roitman; Yuval Mazor; Batia Liefshitz; Shay Ben-Aroya; Martin Kupiec

    2009-01-01

    Mutations in the ELG1 gene of yeast lead to genomic instability, manifested in high levels of genetic recombination, chromosome loss, and gross chromosomal rearrangements. Elg1 shows similarity to the large subunit of the Replication Factor C clamp loader, and forms a RFC-like (RLC) complex in conjunction with the 4 small RFC subunits. Two additional RLCs exist in yeast: in one of them the large subunit is Ctf18, and in the other, Rad24. Ctf18 has been characterized as the RLC that functions ...

  2. Clamping of ferroelectric and antiferromagnetic order parameters of YMnO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Hanamura, Eiichi [Chitose Institute of Science and Technology, 758-65 Bibi, Chitose, Hokkaido (Japan); Hagita, Katsumi [Japan Science and Technology Corporation (CREST), 758-65 Bibi, Chitose, Hokkaido (Japan); Tanabe, Yukito [Department of Applied Physics, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo (Japan)

    2003-01-29

    It was observed that a ferroelectric domain boundary (DB) is always accompanied by an antiferromagnetic DB in hexagonal YMnO{sub 3}, by means of interference effects of the second-harmonic signal. The clamping of these two order parameters at the ferroelectric DB is shown theoretically to originate from Dzyaloshinski-Moriya interaction. This interaction favouring a right angle between the neighbouring spins is found to be operative within the DB and to reverse the direction of the spins across the ferroelectric DB. (letter to the editor)

  3. Cyclic peptide inhibitors of the β-sliding clamp in Staphylococcus aureus

    DEFF Research Database (Denmark)

    Kjelstrup, Susanne; Hansen, Paula Melo Paulon; Thomsen, Line Elnif;

    2013-01-01

    Interaction between pairs of Staphylococcus aureus replication proteins was detected in an Escherichia coli based two-hybrid analysis. A reverse two-hybrid system was constructed for selection of compounds that hindered interaction between interacting protein pairs. A number of cyclic peptides......, from a library generated by the split intein-mediated circular ligation of peptides and proteins technology, were found to interfere with dimerization of the β-sliding clamp of the replisome. Two 8-mer peptides were analyzed in more detail. Both inhibited DNA replication, led to SOS induction, altered...

  4. Dynamic Gain-Clamped Amplifier with Backward-Injection of a Fabry-Perot Laser

    Institute of Scientific and Technical Information of China (English)

    Chien-Hung Yeh; Chih-Yang Chen; Chien-Chung Lee; Sien Chi

    2003-01-01

    We have been experimentally demonstrated an active control technique of dynamic gain-clamped spectra for the erbium-doped fiber amplifiers (EDFA's) by a backward-injected Fabry-Perot (F-P) laser into this EDFA. In addition, employing a short length erbium-doped fiber (EDF) that not cause any gain saturation for preamplification in front of this amplifier module, it can reduce the noise figure degradation and simultaneously achieve gain variation from 11.1 dB to 0.5 dB for 10 dB input power level change.

  5. Dynamic Gain-Clamped Amplifier with Backward-Injection of a Fabry-Perot Laser

    Institute of Scientific and Technical Information of China (English)

    Chien-Hung; Yeh; Chih-Yang; Chen; Chien-Chung; Lee; Sien; Chi

    2003-01-01

    We have been experimentally demonstrated an active control technique of dynamic gain-clamped spectra for theerbium-doped fiber amplifiers (EDFA's) by a backward-injected Fabry-Perot (F-P) laser into this EDFA. In addition, employing a short length erbium-doped fiber (EDF) that not cause any gain saturation for preamplification in front of this amplifier module, it can reduce the noise figure degradation and simultaneously achieve gain variation from 11.1 dB to 0.5 dB for 10 dB input power level change.

  6. Visual patch clamp recording of neurons in thick portions of the adult spinal cord

    DEFF Research Database (Denmark)

    Munch, Anders Sonne; Smith, Morten; Moldovan, Mihai

    2010-01-01

    The study of visually identified neurons in slice preparations from the central nervous system offers considerable advantages over in vivo preparations including high mechanical stability in the absence of anaesthesia and full control of the extracellular medium. However, because of their relative...... enlargement of the spinal cord. With a conventional upright microscope in which the light condenser was carefully adjusted, we could visualize neurons present at the surface of the slice and record them with the whole-cell patch clamp technique. We show that neurons present in the middle of the preparation...

  7. Longitudinal relaxation of mechanically clamped KH2PO4 type crystals

    Directory of Open Access Journals (Sweden)

    R.R. Levitskii

    2012-10-01

    Full Text Available Within the framework of a modified proton ordering model of the KH2PO4 family ferroelectric crystals, taking into account a linear over the strain ϵ6 contribution into the proton system energy, we obtain an expression for longitudinal dynamic dielectric permittivity of a mechanically clamped crystal using the four-particle cluster approximation and the dynamic Glauber approach. At a proper choice of the model parameters, we obtain a good quantitative description of available experimental data for these crystals.

  8. Five-Level Z-Source Neutral Point-Clamped Inverter

    DEFF Research Database (Denmark)

    Gao, F.; Loh, P.C.; Blaabjerg, Frede;

    2007-01-01

    -through scheme reveals the hidden theories in the five-level Z-source NPC inverter unlike the operational principle appeared in the general two-level Z-source inverter, so that the five-level Z-source NPC inverter can be designed with the modulation of carrier-based phase disposition (PD) or alternative phase......This paper proposes a five-level Z-source neutralpoint- clamped (NPC) inverter with two Z-source networks functioning as intermediate energy storages coupled between dc sources and NPC inverter circuitry. Analyzing the operational principles of Z-source network with partial dclink shoot...

  9. Single stage buck-boost DC-AC neutral point clamped inverter

    DEFF Research Database (Denmark)

    Mo, Wei; Loh, Poh Chiang; Andrew, A.;

    2012-01-01

    This paper proposes a new single stage buck-boost DC-AC neutral point clamped inverter topology which integrates the cascaded configurations of recently introduced inductor-capacitor-capacitor-transformer impedance source network (by Adamowicz) and classic NPC configuration. As a consequence...... windings thus preventing the core from saturation; lowers the voltage stresses and power losses of inverter switches and reduces the sizes of filtering devices and as well as obtains better output performance compared to the original two-level Z-source inverters. A phase disposition pulse width modulation...

  10. Modeling of Busbars in High Power Neutral Point Clamped Three-Level Inverters

    Institute of Scientific and Technical Information of China (English)

    YI Rung; ZHAO Zhengming; ZHONG Yulin

    2008-01-01

    The busbars in high power neutral point clamped three-level inverters are modeled using the Maxwell Q3D Extractor software, which is based on the partial element equivalent circuits method. The equivalent circuits of the busbars and devices model are simulated in the electric simulator PSIM to analyze the effects of the parasitic inductance on the switching characteristics of the integrated gate commutatedthyristor (IGCT) in different topology positions. The simulation results agree well with the measured imped-ance analyzer results and the IGCT test results, which proves the effectiveness of the modeling method for the large, complex busbars.

  11. Direct-conversion switching-mode audio power amplifier with active capacitive voltage clamp

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.; Andersen, Michael A.E.

    2005-07-01

    This paper discusses the advantages and problems when implementing direct energy conversion switching-mode audio power amplifiers. It is shown that the total integration of the power supply and Class D audio power amplifier into one compact direct converter can simplify design, increase efficiency and integration level, reduce product volume and lower its cost. As an example, the principle of operation and the measurements made on a direct-conversion switching-mode audio power amplifier with active capacitive voltage clamp are presented. (au)

  12. Surface analysis of anodized aluminum clamps from NASA-LDEF satellite

    Science.gov (United States)

    Grammer, H. L.; Wightman, J. P.; Young, Philip R.

    1992-01-01

    Surface analysis results of selected anodized aluminum clamps containing black (Z306) and white (A276) paints which received nearly six years of Low Earth Orbit (LEO) exposure on the Long Duration Exposure Facility are reported. Surface analytical techniques, including x-ray photoelectron spectroscopy (XPS), Auger electron spectroscopy (AES), and scanning electron microscopy/energy dispersive analysis by x-ray (SEM/EDAX), showed significant differences in the surface composition of these materials depending upon the position on the LDEF. Differences in the surface composition are attributed to varying amounts of atomic oxygen and vacuum ultraviolet radiation (VUV). Silicon containing compounds were the primary contaminant detected on the materials.

  13. Effect of La3+ on myocardiac potassium channels revealed by patch-clamp technique

    Institute of Scientific and Technical Information of China (English)

    XUE Shaowu; YANG Pin

    2005-01-01

    The effect of La3+ on potassium channels in rat ventricular myocytes was investigated using the whole-cell patch-clamp recording mode. The Ca2+-independent voltage- activated outward K+ current was activated by the depolarizing pulse in enzymatically isolated rat ventricular myocytes. After addition of different concentrations La3+ to the bath solution, the outward K+ current was depressed gradually. The inhibition effect was in a concentration-dependent manner. The phenomena of the outward K+ current, being the main repolarizing current suppressed by La3+, suggest that the effect of lanthanides on myocardial function should be exploited further.

  14. Characterization of the IEC 61000-4-6 Electromagnetic Clamp for Conducted-Immunity Testing

    Science.gov (United States)

    Grassi, F.; Pignari, S. A.; Spadacini, G.; Toscani, N.; Pelissou, P.

    2016-05-01

    A multiconductor transmission line model (MTL) is used to investigate the operation of the IEC 61000-4-6 electromagnetic (EM) clamp in a conducted-immunity test setup for aerospace applications. Aspects of interest include the performance of such a coupling device at very high frequencies (up to 1 GHz), and for extreme values of the common-mode impedance of equipment (short circuits, open circuits). The MTL model is finally exploited to predict the frequency response of coupling and decoupling factors defined in the IEC 61000-4-6 standard.

  15. On the use of Cu:Be clamp cells in magnetization and neutron scattering studies

    Energy Technology Data Exchange (ETDEWEB)

    Pfleiderer, C [Physikalisches Institut, Universitaet Karlsruhe, D-76128 Karlsruhe (Germany); Huxley, A D [DRFMC-SPSMS, CEA Grenoble, F-38054 Grenoble Cedex 9 (France); Hayden, S M [HH Wills Physics Laboratory, University of Bristol, Bristol BS8 1TL (United Kingdom)

    2005-10-12

    The use of miniature clamp cells made of Cu:Be for magnetization and neutron scattering studies in the medium pressure range is reviewed by giving recent results achieved in studies of UGe{sub 2}, MnSi and ZrZn{sub 2}. The experiments reviewed here establish in particular that small samples can be studied rather well at high pressures using a variety of different techniques, notably conventional diffraction, cold and thermal neutron triple axes and small-angle neutron scattering.

  16. Characterization of the insulin sensitivity of ghrelin receptor KO mice using glycemic clamps

    Directory of Open Access Journals (Sweden)

    Morgan Kristen

    2011-01-01

    Full Text Available Abstract Background We and others have demonstrated previously that ghrelin receptor (GhrR knock out (KO mice fed a high fat diet (HFD have increased insulin sensitivity and metabolic flexibility relative to WT littermates. A striking feature of the HFD-fed GhrR KO mouse is the dramatic decrease in hepatic steatosis. To characterize further the underlying mechanisms of glucose homeostasis in GhrR KO mice, we conducted both hyperglycemic (HG and hyperinsulinemic-euglycemic (HI-E clamps. Additionally, we investigated tissue glucose uptake and specifically examined liver insulin sensitivity. Results Consistent with glucose tolerance-test data, in HG clamp experiments, GhrR KO mice showed a reduction in glucose-stimulated insulin release relative to WT littermates. Nevertheless, a robust 1st phase insulin secretion was still achieved, indicating that a healthy β-cell response is maintained. Additionally, GhrR KO mice demonstrated both a significantly increased glucose infusion rate and significantly reduced insulin requirement for maintenance of the HG clamp, consistent with their relative insulin sensitivity. In HI-E clamps, both LFD-fed and HFD-fed GhrR KO mice showed higher peripheral insulin sensitivity relative to WT littermates as indicated by a significant increase in insulin-stimulated glucose disposal (Rd, and decreased hepatic glucose production (HGP. HFD-fed GhrR KO mice showed a marked increase in peripheral tissue glucose uptake in a variety of tissues, including skeletal muscle, brown adipose tissue and white adipose tissue. GhrR KO mice fed a HFD also showed a modest, but significant decrease in conversion of pyruvate to glucose, as would be anticipated if these mice displayed increased liver insulin sensitivity. Additionally, the levels of UCP2 and UCP1 were reduced in the liver and BAT, respectively, in GhrR KO mice relative to WT mice. Conclusions These results indicate that improved glucose homeostasis of GhrR KO mice is

  17. Five-Level Z-Source Neutral Point-Clamped Inverter

    DEFF Research Database (Denmark)

    Gao, F.; Loh, P.C.; Blaabjerg, Frede

    2007-01-01

    -through scheme reveals the hidden theories in the five-level Z-source NPC inverter unlike the operational principle appeared in the general two-level Z-source inverter, so that the five-level Z-source NPC inverter can be designed with the modulation of carrier-based phase disposition (PD) or alternative phase......This paper proposes a five-level Z-source neutralpoint- clamped (NPC) inverter with two Z-source networks functioning as intermediate energy storages coupled between dc sources and NPC inverter circuitry. Analyzing the operational principles of Z-source network with partial dclink shoot...

  18. Transverse Vibrations of Clamped and Simply-Supported Circular Plates with Two Dimensional Thickness Variation

    Directory of Open Access Journals (Sweden)

    N. Bhardwaj

    2012-01-01

    Full Text Available Two dimensional boundary characteristic orthonormal polynomials are used in the Ritz method for the vibration analysis of clamped and simply-supported circular plates of varying thickness. The thickness variation in the radial direction is linear whereas in the circumferential direction the thickness varies according to cos kθ, where k is an integer. In order to verify the validity, convergence and accuracy of the results, comparison studies are made against existing results for the special case of linearly tapered thickness plates. Variations in frequencies for the first six normal modes of vibration and mode shapes for various taper parameters are presented.

  19. Five-Level Active-Neutral-Point-Clamped DC/DC Converter

    DEFF Research Database (Denmark)

    Liu, Dong; Deng, Fujin; Chen, Zhe

    2016-01-01

    reliability. Furthermore, a capacitor voltage control strategy by alternating two operation modes of the proposed modulation strategy is proposed to balance the voltage of the flying capacitor, which ensures multi-level voltages producing. Finally, the performance of the proposed converter and control......Multi-level converters are getting more and more attentions because of their obvious merits such as lower voltage stress and harmonic, smaller size of output filters, and so on. In this paper, a five-level active-neutral-point-clamped (5L-ANPC) dc/dc converter is proposed for power transfer...

  20. Assimilation of temperature and hydraulic gradients for quantifying the spatial variability of streambed hydraulics

    Science.gov (United States)

    Huang, Xiang; Andrews, Charles B.; Liu, Jie; Yao, Yingying; Liu, Chuankun; Tyler, Scott W.; Selker, John S.; Zheng, Chunmiao

    2016-08-01

    Understanding the spatial and temporal characteristics of water flux into or out of shallow aquifers is imperative for water resources management and eco-environmental conservation. In this study, the spatial variability in the vertical specific fluxes and hydraulic conductivities in a streambed were evaluated by integrating distributed temperature sensing (DTS) data and vertical hydraulic gradients into an ensemble Kalman filter (EnKF) and smoother (EnKS) and an empirical thermal-mixing model. The formulation of the EnKF/EnKS assimilation scheme is based on a discretized 1D advection-conduction equation of heat transfer in the streambed. We first systematically tested a synthetic case and performed quantitative and statistical analyses to evaluate the performance of the assimilation schemes. Then a real-world case was evaluated to calculate assimilated specific flux. An initial estimate of the spatial distributions of the vertical hydraulic gradients was obtained from an empirical thermal-mixing model under steady-state conditions using a constant vertical hydraulic conductivity. Then, this initial estimate was updated by repeatedly dividing the assimilated specific flux by estimates of the vertical hydraulic gradients to obtain a refined spatial distribution of vertical hydraulic gradients and vertical hydraulic conductivities. Our results indicate that optimal parameters can be derived with fewer iterations but greater simulation effort using the EnKS compared with the EnKF. For the field application in a stream segment of the Heihe River Basin in northwest China, the average vertical hydraulic conductivities in the streambed varied over three orders of magnitude (5 × 10-1 to 5 × 102 m/d). The specific fluxes ranged from near zero (qz < ±0.05 m/d) to ±1.0 m/d, while the vertical hydraulic gradients were within the range of -0.2 to 0.15 m/m. The highest and most variable fluxes occurred adjacent to a debris-dam and bridge pier. This phenomenon is very likely