WorldWideScience

Sample records for hydraulic power supplies

  1. Dynamic Analysis & Characterization of Conventional Hydraulic Power Supply Units

    DEFF Research Database (Denmark)

    Schmidt, Lasse; Liedhegener, Michael; Bech, Michael Møller

    2016-01-01

    Hydraulic power units operated as constant supply pres-sure systems remain to be widely used in the industry, to supply valve controlled hydraulic drives etc., where the hydraulic power units are constituted by variable pumps with mechanical outlet pressure control, driven by induction motors...... and drives will reduce the flow-to-pressure gain of the supply system, and hence increase the time constant of the sup-ply pressure dynamics. A consequence of this may be large vari-ations in the supply pressure, hence large variations in the pump shaft torque, and thereby the induction motor load torque......, with possible excitation of the induction motor dynamics as a result. In such cases, the coupled dynamics of the pressure controlled pump and induction motor may influence the supply pressure sig-nificantly, possibly affecting the dynamics of the supplied drives, especially in cases where pilot operated valves...

  2. Mobile hydraulic power supply. Liquid piston Stirling engine pump

    Energy Technology Data Exchange (ETDEWEB)

    Ven, James D. van de [100 Institute Road, Department of Mechanical Engineering, Worcester Polytechnic Institute, Worcester, MA 01609 (United States)

    2009-11-15

    Conventional mobile hydraulic power supplies involve numerous kinematic connections and are limited by the efficiency, noise, and emissions of internal combustion engines. The Stirling cycle possesses numerous benefits such as the ability to operate from any heat source, quiet operation, and high theoretical efficiency. The Stirling engine has seen limited success due to poor heat transfer in the working chambers, difficulty sealing low-molecular weight gases at high pressure, and non-ideal piston displacement profiles. As a solution to these limitations, a liquid piston Stirling engine pump is proposed. The liquid pistons conform to irregular volumes, allowing increased heat transfer through geometry features on the interior of the working chambers. Creating near-isothermal operation eliminates the costly external heat exchangers and increases the engine efficiency through decreasing the engine dead space. The liquid pistons provide a positive gas seal and thermal transport to the working chambers. Controlling the flow of the liquid pistons with valves enables matching the ideal Stirling cycle and creates a direct hydraulic power supply. Using liquid hydrogen as a fuel source allows cooling the compression side of the engine before expanded the fuel into a gas and combusting it to heat the expansion side of the engine. Cooling the compression side not only increases the engine power, but also significantly increases the potential thermal efficiency of the engine. A high efficiency Stirling engine makes energy regeneration through reversing the Stirling cycle practical. When used for regeneration, the captured energy can be stored in thermal batteries, such as a molten salt. The liquid piston Stirling engine pump requires further research in numerous areas such as understanding the behavior of the liquid pistons, modeling and optimization of a full engine pump, and careful selection of materials for the extreme operating temperatures. Addressing these obtainable

  3. 46 CFR 111.97-5 - Electric and hydraulic power supply.

    Science.gov (United States)

    2010-10-01

    ... by one or more motor-driven hydraulic pumps that can operate from the final source of the emergency lighting and power system. (d) The motor-driven hydraulic pumps must automatically maintain the accumulator... 46 Shipping 4 2010-10-01 2010-10-01 false Electric and hydraulic power supply. 111.97-5...

  4. Power Management in Mobile Hydraulic Applications - An Approach for Designing Hydraulic Power Supply Systems

    DEFF Research Database (Denmark)

    Pedersen, Henrik Clemmensen

    2004-01-01

    in a project to develop rules and methods for designing and controlling mobile hydraulic systems in the most energy efficient way, when also considering the operational aspects of the system. The paper first describes the thoughts and ideas behind the project and then focus on an automated approach to design......Throughout the last three decades energy consumption has become one of the primary design aspects in hydraulic systems, especially for mobile hydraulic systems, as power and cooling capacity here is at limited disposal. Considering the energy usage, this is dependent on component efficiency......, but even more important is the system topology. However, there are no rules or guidelines for what system topology to choose for a given application, in order to obtain the most energy efficient system, nor for how the energy should be distributed in the system. This paper describes the approach taken...

  5. Water supply pipe dimensioning using hydraulic power dissipation

    Science.gov (United States)

    Sreemathy, J. R.; Rashmi, G.; Suribabu, C. R.

    2017-07-01

    Proper sizing of the pipe component of water distribution networks play an important role in the overall design of the any water supply system. Several approaches have been applied for the design of networks from an economical point of view. Traditional optimization techniques and population based stochastic algorithms are widely used to optimize the networks. But the use of these approaches is mostly found to be limited to the research level due to difficulties in understanding by the practicing engineers, design engineers and consulting firms. More over due to non-availability of commercial software related to the optimal design of water distribution system,it forces the practicing engineers to adopt either trial and error or experience-based design. This paper presents a simple approach based on power dissipation in each pipeline as a parameter to design the network economically, but not to the level of global minimum cost.

  6. An Optimisation Approach Applied to Design the Hydraulic Power Supply for a Forklift Truck

    DEFF Research Database (Denmark)

    Pedersen, Henrik Clemmensen; Andersen, Torben Ole; Hansen, Michael Rygaard

    2004-01-01

    -level optimisation approach, and is in the current paper exemplified through the design of the hydraulic power supply for a forklift truck. The paper first describes the prerequisites for the method and then explains the different steps in the approach to design the hydraulic system. Finally the results...... of the optimisation example for the forklift truck are presented along with a discussion of the method....

  7. An Optimisation Approach Applied to Design the Hydraulic Power Supply for a Forklift Truck

    DEFF Research Database (Denmark)

    Pedersen, Henrik Clemmensen; Andersen, Torben Ole; Hansen, Michael Rygaard

    2004-01-01

    This paper describes the first part of a method that may be used in the design of the most energy efficient hydraulic opencircuit systems, when also considering the operational aspects of the system given in the design specifications. The method builds on a numerically based multi-level optimisat......This paper describes the first part of a method that may be used in the design of the most energy efficient hydraulic opencircuit systems, when also considering the operational aspects of the system given in the design specifications. The method builds on a numerically based multi...

  8. Hydraulic Actuators with Autonomous Hydraulic Supply for the Mainline Aircrafts

    Directory of Open Access Journals (Sweden)

    I. S. Shumilov

    2014-01-01

    Full Text Available Applied in the aircraft control systems, hydraulic servo actuators with autonomous hydraulic supply, so-called, hydraulic actuators of integrated configuration, i.e. combination of a source of hydraulic power and its load in the single unit, are aimed at increasing control system reliability both owing to elimination of the pipelines connecting the actuator to the hydraulic supply source, and owing to avoidance of influence of other loads failure on the actuator operability. Their purpose is also to raise control system survivability by eliminating the long pipeline communications and their replacing for the electro-conductive power supply system, thus reducing the vulnerability of systems. The main reason for a delayed application of the hydraulic actuators in the cutting-edge aircrafts was that such aircrafts require hydraulic actuators of considerably higher power with considerable heat releases, which caused an unacceptable overheat of the hydraulic actuators. Positive and negative sides of the hydraulic actuators, their alternative options of increased reliability and survivability, local hydraulic systems as an advanced alternative to independent hydraulic actuators are considered.Now to use hydraulic actuators in mainline aircrafts is inexpedient since there are the unfairly large number of the problems reducing, first and last, safety of flights, with no essential weight and operational advantages. Still works to create competitive hydraulic actuators ought to be continued.Application of local hydraulic systems (LHS will allow us to reduce length of pressure head and drain pipelines and mass of pipelines, as well as to raise their general fail-safety and survivability. Application of the LHS principle will allow us to use a majority of steering drive advantages. It is necessary to allocate especially the following:- ease of meeting requirements for the non-local spread of the engine weight;- essentially reducing length and weight of

  9. Debugging on High-voltage Power Supply,Focusing Power Supply and Magnetic Field Power Supply

    Institute of Scientific and Technical Information of China (English)

    TU; Rui

    2015-01-01

    High-voltage power supply,focusing power supply and magnetic field power supply are the main parts of the power supply system of the EMIS(Electro-Magnetic Isotope Separator)supplying the ion source.In 2015,a high-voltage power supply,power supply for focusing and

  10. Solar mobile power supply

    OpenAIRE

    Hu, Libian

    2014-01-01

    The solar mobile power supply is a comprehensive energy saving and environment protective product. Besides, it consists of solar panels, storage battery and controller as well as other important components. Based on the traditional solar charging circuit, this solar power supply combines the 5V USB interface and 12V adjustable circuit as well as the 220V inverter and power adapter to greatly improve the function of the power system.

  11. Mobile Uninterruptible Power Supply

    Science.gov (United States)

    Mears, Robert L.

    1990-01-01

    Proposed mobile unit provides 20 kVA of uninterruptible power. Used with mobile secondary power-distribution centers to provide power to test equipment with minimal cabling, hazards, and obstacles. Wheeled close to test equipment and system being tested so only short cable connections needed. Quickly moved and set up in new location. Uninterruptible power supply intended for tests which data lost or equipment damaged during even transient power failure.

  12. Radioisotope Power Supply Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Between 1998 and 2003, Hi-Z Technology developed and built a 40 mW radioisotope power supply (RPS) that used a 1 watt radioisotope heater unit (RHU) as the energy...

  13. Rechargeable power supply

    NARCIS (Netherlands)

    Den Uijl, S.; Bouman, C.; Smit, W.

    2006-01-01

    The invention relates to a rechargeable power supply suitable to be used in a battery-operated device comprising at least one supercapacitor and at least a first and a second DC-DC converter connected in series, wherein the supercapacitor is connectable to an entry of the first DC-DC converter and t

  14. Discontinuous Mode Power Supply

    Science.gov (United States)

    Lagadinos, John; Poulos, Ethel

    2012-01-01

    A document discusses the changes made to a standard push-pull inverter circuit to avoid saturation effects in the main inverter power supply. Typically, in a standard push-pull arrangement, the unsymmetrical primary excitation causes variations in the volt second integral of each half of the excitation cycle that could lead to the establishment of DC flux density in the magnetic core, which could eventually cause saturation of the main inverter transformer. The relocation of the filter reactor normally placed across the output of the power supply solves this problem. The filter reactor was placed in series with the primary circuit of the main inverter transformer, and is presented as impedance against the sudden changes on the input current. The reactor averaged the input current in the primary circuit, avoiding saturation of the main inverter transformer. Since the implementation of the described change, the above problem has not reoccurred, and failures in the main power transistors have been avoided.

  15. Load Feedforward and Feedback Compounded Compensation Control for Variable Speed Hydraulic Power Supply%变转速液压动力源的负载前馈反馈复合补偿控制

    Institute of Scientific and Technical Information of China (English)

    李昭; 谷立臣; 马玉

    2016-01-01

    研究了前馈控制和反馈控制的原理及优缺点,提出采用负载前馈反馈复合补偿控制策略实现液压动力源在典型工况下的恒流量控制.以变转速机电液系统实验平台为基础,建立变转速液压动力源的Simulink仿真模型,分别在简单PID反馈控制和复合补偿控制策略下进行仿真和实验,结果证明了该复合补偿控制策略在液压动力源恒流量控制中的可行性和有效性,其抗负载扰动性能明显优于简单PID反馈控制.%The principles and characteristics of feedforward control and feedback control were stud-ied,a method called the load feedforward and feedback compounded compensation control strategy was proposed herein to realize the constant flow control of hydraulic power supply under typical operating conditions.Based on the experimental platform of mechanical-electrical-hydraulic system,a Simulink model of variable speed hydraulic power supply was established.The simulations and experiments were carried out respectively under a simple PID feedback control and a compounded compensation control strategy.The results verify the compounded compensation control strategy is efficient and fea-sible in constant flow control of hydraulic power supply,and the resistance to load disturbance of the compounded compensation control strategy is superior to the simple PID control .

  16. Measurement of Pulsed Power Supply

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Power supply system is an important subsystem of CSR. To apply for running, the parameters of power supply must be fit the design’s demands. We have tested all prototype of power supply as follows.The DC stability measurement is that the power supply runs in certain current level from the lower value to the normal value. In every current level, we acquire about 550 data by digital meter (model 7081) in 8 h.

  17. Modular High Voltage Power Supply

    Energy Technology Data Exchange (ETDEWEB)

    Newell, Matthew R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-18

    The goal of this project is to develop a modular high voltage power supply that will meet the needs of safeguards applications and provide a modular plug and play supply for use with standard electronic racks.

  18. Reliability Estimates for Power Supplies

    Energy Technology Data Exchange (ETDEWEB)

    Lee C. Cadwallader; Peter I. Petersen

    2005-09-01

    Failure rates for large power supplies at a fusion facility are critical knowledge needed to estimate availability of the facility or to set priorties for repairs and spare components. A study of the "failure to operate on demand" and "failure to continue to operate" failure rates has been performed for the large power supplies at DIII-D, which provide power to the magnet coils, the neutral beam injectors, the electron cyclotron heating systems, and the fast wave systems. When one of the power supplies fails to operate, the research program has to be either temporarily changed or halted. If one of the power supplies for the toroidal or ohmic heating coils fails, the operations have to be suspended or the research is continued at de-rated parameters until a repair is completed. If one of the power supplies used in the auxiliary plasma heating systems fails the research is often temporarily changed until a repair is completed. The power supplies are operated remotely and repairs are only performed when the power supplies are off line, so that failure of a power supply does not cause any risk to personnel. The DIII-D Trouble Report database was used to determine the number of power supply faults (over 1,700 reports), and tokamak annual operations data supplied the number of shots, operating times, and power supply usage for the DIII-D operating campaigns between mid-1987 and 2004. Where possible, these power supply failure rates from DIII-D will be compared to similar work that has been performed for the Joint European Torus equipment. These independent data sets support validation of the fusion-specific failure rate values.

  19. Practical switching power supply design

    CERN Document Server

    Brown, Martin C

    1990-01-01

    Take the ""black magic"" out of switching power supplies with Practical Switching Power Supply Design! This is a comprehensive ""hands-on"" guide to the theory behind, and design of, PWM and resonant switching supplies. You'll find information on switching supply operation and selecting an appropriate topology for your application. There's extensive coverage of buck, boost, flyback, push-pull, half bridge, and full bridge regulator circuits. Special attention is given to semiconductors used in switching supplies. RFI/EMI reduction, grounding, testing, and safety standards are also deta

  20. CSR Pulsed Switching Power Supplies

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    In 2001, CSR power supply system made a great progress. Three prototypes were designed for CSR quadruple and correct magnet. Three different companies provided the three prototypes, but the same circuit-chopper were employed. The simplified diagram is showed in Fig.1. All pulsed switching power supply prototypes were tested successfully before the end of 2001.

  1. TRANSISTOR HIGH VOLTAGE POWER SUPPLY

    Science.gov (United States)

    Driver, G.E.

    1958-07-15

    High voltage, direct current power supplies are described for use with battery powered nuclear detection equipment. The particular advantages of the power supply described, are increased efficiency and reduced size and welght brought about by the use of transistors in the circuit. An important feature resides tn the employment of a pair of transistors in an alternatefiring oscillator circuit having a coupling transformer and other circuit components which are used for interconnecting the various electrodes of the transistors.

  2. Power management in hydraulically actuated mobile equipment

    DEFF Research Database (Denmark)

    Pedersen, Henrik Clemmensen; Andersen, Torben Ole; Hansen, Michael Rygaard

    2008-01-01

    The focus of the current paper is on the control of hydraulic systems when utilizing the advances that electronic control may bring with regard to power management, prioritized flow sharing and anti-stall, arising from being able to control both pump, valves and engine electronically. A simple mo...

  3. Hydraulic Bureaucracies and the Hydraulic Mission: Flows of Water, Flows of Power

    Directory of Open Access Journals (Sweden)

    François Molle

    2009-10-01

    Full Text Available Anchored in 19th century scientism and an ideology of the domination of nature, inspired by colonial hydraulic feats, and fuelled by technological improvements in high dam constructions and power generation and transmission, large-scale water resources development has been a defining feature of the 20th century. Whether out of a need to increase food production, raise rural incomes, or strengthen state building and the legitimacy of the state, governments – North and South, East and West – embraced the 'hydraulic mission' and entrusted it to powerful state water bureaucracies (hydrocracies. Engaged in the pursuit of iconic and symbolic projects, the massive damming of river systems, and the expansion of large-scale public irrigation these hydrocracies have long remained out of reach. While they have enormously contributed to actual welfare, including energy and food generation, flood protection and water supply to urban areas, infrastructural development has often become an end in itself, rather than a means to an end, fuelling rent-seeking and symbolising state power. In many places projects have been challenged on the basis of their economic, social or environmental impacts. Water bureaucracies have been challenged internally (within the state bureaucracies or through political changes and externally (by critiques from civil society and academia, or by reduced funding. They have endeavoured to respond to these challenges by reinventing themselves or deflecting reforms. This paper analyses these transformations, from the emergence of the hydraulic mission and associated water bureaucracies to their adjustment and responses to changing conditions.

  4. Mars sample return power supply

    Science.gov (United States)

    Hoang, Don; Ludwigs, Sharon; Schmitz, Paul; Wright, John

    A power supply is designed for a vehicle able to operate on the surface of Mars for a period of 5 to 10 years. This vehicle will be used for sample and data collection. The design is based on the assumption that the vehicle will be unmanned. Also, there will be no means by which components could be repaired or replaced while on the Martian surface. A consequence of this is that all equipment must meet high standards of reliability and, if possible, redundancy. Power will be supplied to the vehicle by means of a General Purpose Heat Source capable of producing a minimum of 7 kW of thermal power. The heat generated from the General Purpose Heat Source will be transferred to a Stirling engine via hot side heat pipes. The Stirling engine will then convert this heat into 2 kW of electrical power. Cold side heat pipes will be used to carry away waste heat, which will be released to the Martian environment via radiators connected to the end of the cold side heat pipes.

  5. Hydraulic Power Plant Machine Dynamic Diagnosis

    Directory of Open Access Journals (Sweden)

    Hans Günther Poll

    2006-01-01

    Full Text Available A method how to perform an entire structural and hydraulic diagnosis of prototype Francis power machines is presented and discussed in this report. Machine diagnosis of Francis units consists on a proper evaluation of acquired mechanical, thermal and hydraulic data obtained in different operating conditions of several rotary and non rotary machine components. Many different physical quantities of a Francis machine such as pressure, strains, vibration related data, water flow, air flow, position of regulating devices and displacements are measured in a synchronized way so that a relation of cause an effect can be developed for each operating condition and help one to understand all phenomena that are involved with such kind of machine. This amount of data needs to be adequately post processed in order to allow correct interpretation of the machine dynamics and finally these data must be compared with the expected calculated data not only to fine tuning the calculation methods but also to accomplish fully understanding of the influence of the water passages on such machines. The way how the power plant owner has to operate its Francis machines, many times also determined by a central dispatcher, has a high influence on the fatigue life time of the machine components. The diagnostic method presented in this report helps one to understand the importance of adequate operation to allow a low maintenance cost for the entire power plant. The method how to acquire these quantities is discussed in details together with the importance of correct sensor balancing, calibration and adequate correlation with the physical quantities. Typical results of the dynamic machine behavior, with adequate interpretation, obtained in recent measurement campaigns of some important hydraulic turbines were presented. The paper highlights the investigation focus of the hydraulic machine behavior and how to tailor the measurement strategy to accomplish all goals. Finally some

  6. 47 CFR 80.1015 - Power supply.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Power supply. 80.1015 Section 80.1015... MARITIME SERVICES Radiotelephone Installations Required by the Bridge-to-Bridge Act § 80.1015 Power supply. (a) There must be readily available for use under normal load conditions, a power supply...

  7. EU ENERGY STAR Certified Uninterruptible Power Supplies

    Science.gov (United States)

    Certified models meet all ENERGY STAR requirements as listed in the Version 1.0 ENERGY STAR Program Requirements for Uninterruptible Power Supplies that are effective as of August 1, 2012. A detailed listing of key efficiency criteria are available at http://www.energystar.gov/index.cfm?c=uninterruptible_power_supplies.pr_crit_uninterruptible_power_supplies

  8. ENERGY STAR Certified Uninterruptible Power Supplies

    Science.gov (United States)

    Certified models meet all ENERGY STAR requirements as listed in the Version 1.0 ENERGY STAR Program Requirements for Uninterruptible Power Supplies that are effective as of August 1, 2012. A detailed listing of key efficiency criteria are available at http://www.energystar.gov/index.cfm?c=uninterruptible_power_supplies.pr_crit_uninterruptible_power_supplies

  9. Hydraulic power take-off for wave energy systems

    DEFF Research Database (Denmark)

    Christensen, Georg Kronborg

    2001-01-01

    Investigation and laboratory experiments with a hydraulic power conversion system for converting forces from a 2.5m diamter float to extract energy from seawaves. The test rig consists of a hydraulic wave simulator and a hydraulic point absorber. The absorber converts the incomming forces...

  10. Design of intrinsically safe power supply

    Institute of Scientific and Technical Information of China (English)

    LI Rui-jin; JIN Lin

    2012-01-01

    Aiming to make a high power direct current supply safely used in coal mine production,this paper made a deep research on characteristics of intrinsically safe power supply,using the mathematical model established according to coal mine intrinsic safety standards.It provides theory support for the application of high power intrinsically safe power supply.The released energy of output short circuit of switch power supply,and the close related factors that influence the biggest output short-circuit spark discharge energy are the theoretical basis of the power supply.It is shown how to make a high power intrinsically safe power supply using the calculated values in the mathematical model,and take values from intrinsically safe requirements parameters scope,then this theoretical calculation value can be developed as the ultimate basis for research of the power supply.It gets the identification method of intrinsically safe from mathematics model of intrinsically safe power supply characteristics study,which solves the problem of theory and application of designing different power intrinsically safe power supply,and designs a kind of high power intrinsically safe power supply through this method.

  11. Research on hydraulic-powered roof supports test problems

    Institute of Scientific and Technical Information of China (English)

    SUN Hong-bo; JIANG Jin-qiu; MA Qiang

    2011-01-01

    The load-bearing characters of hydraulic-powered roof support with dual telescopic legs were analyzed. With a specific type hydraulic-powered roof support with dual telescopic legs for research object, the inside load test problems in factories was analyzed, and the correct test methods were given, which can enhance the test efficiency and make the factories away from the error design of hydraulic-powered roof supports and legs.

  12. A new bipolar Qtrim power supply system

    Energy Technology Data Exchange (ETDEWEB)

    Mi, C. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Bruno, D. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Drozd, J. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Nolan, T. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Orsatti, F. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Heppener, G. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Di Lieto, A. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Schultheiss, C. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Samms, T. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Zapasek, R. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Sandberg, J. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.

    2015-05-03

    This year marks the 15th run of RHIC (Relativistic Heavy Ion Collider) operations. The reliability of superconducting magnet power supplies is one of the essential factors in the entire accelerator complex. Besides maintaining existing power supplies and their associated equipment, newly designed systems are also required based on the physicist’s latest requirements. A bipolar power supply was required for this year’s main quadruple trim power supply. This paper will explain the design, prototype, testing, installation and operation of this recently installed power supply system.

  13. Progress of Power Supply System in 2003

    Institute of Scientific and Technical Information of China (English)

    GaoDaqing; ZhouZhongzu; WuRong; ChenYouxin

    2003-01-01

    CSR power supply system made a great progress in 2003. All power supplies for CSRm E-cooler have been accepted and put into operation since Feb. 2003. And we are preparing to test power supplies of CSRe cooler 31 sets pulsed convertor for CSRm quadruple magnet arrived in IMP. But their output current must be increased from 590 A to 700 A, because of higher beam energy. 12 of them can fit the new request, but the others have to be redesigned and reproduced. The dipole power supply was assembled in plant and by using the power supply was some experiment made. The first test results was excited. Now this device has been installed in IMP and connected with the dipole magnet. We invited a public bidding for RIBLL2 and CSRe power supplies last September. Two companies provided 128 power supplies, which will be delivered to IMP before June 2004.

  14. Novel supplies for powering a sueprconducting magnet

    NARCIS (Netherlands)

    Shevchenko, O.A.; Krooshoop, H.J.G.; Kate, ten H.H.J.; Grunblatt, G.; Shevchenko, A.A.; Kolesnitchenko, A.F.; Sidorenko, V.D.; Grytsina, A.E.; Lysenko, V.; Scherbakov, V.I.; Anashkin, O.; Keylin, V.E.

    2000-01-01

    A family of new supplies for powering superconducting magnets was developed in our institutes. As an example, two supplies are described in the paper. One of the supplies uses superconducting, another-semiconductor-based repetitive switches. Both supplies are able to generate 1 Volt at the high-curr

  15. Advanced Accessory Power Supply Topologies

    Energy Technology Data Exchange (ETDEWEB)

    Marlino, L.D.

    2010-06-15

    This Cooperative Research and Development Agreement (CRADA) began December 8, 2000 and ended September 30, 2009. The total funding provided by the Participant (General Motors Advanced Technology Vehicles [GM]) during the course of the CRADA totaled $1.2M enabling the Contractor (UT-Battelle, LLC [Oak Ridge National Laboratory, a.k.a. ORNL]) to contribute significantly to the joint project. The initial task was to work with GM on the feasibility of developing their conceptual approach of modifying major components of the existing traction inverter/drive to develop low cost, robust, accessory power. Two alternate methods for implementation were suggested by ORNL and both were proven successful through simulations and then extensive testing of prototypes designed and fabricated during the project. This validated the GM overall concept. Moreover, three joint U.S. patents were issued and subsequently licensed by GM. After successfully fulfilling the initial objective, the direction and duration of the CRADA was modified and GM provided funding for two additional tasks. The first new task was to provide the basic development for implementing a cascaded inverter technology into hybrid vehicles (including plug-in hybrid, fuel cell, and electric). The second new task was to continue the basic development for implementing inverter and converter topologies and new technology assessments for hybrid vehicle applications. Additionally, this task was to address the use of high temperature components in drive systems. Under this CRADA, ORNL conducted further research based on GM’s idea of using the motor magnetic core and windings to produce bidirectional accessory power supply that is nongalvanically coupled to the terminals of the high voltage dc-link battery of hybrid vehicles. In order not to interfere with the motor’s torque, ORNL suggested to use the zero-sequence, highfrequency harmonics carried by the main fundamental motor current for producing the accessory power

  16. Low Voltage Power Supply Incorporating Ceramic Transformer

    CERN Document Server

    Imori, M

    2007-01-01

    A low voltage power supply provides the regulated output voltage of 1 V from the supply voltage around 48 V. The low voltage power supply incorporates a ceramic transformer which utilizes piezoelectric effect to convert voltage. The ceramic transformer isolates the secondary from the primary, thus providing the ground isolation between the supply and the output voltages. The ceramic transformer takes the place of the conventional magnetic transformer. The ceramic transformer is constructed from a ceramic bar and does not include any magnetic material. So the low voltage power supply can operate under a magnetic field. The output voltage is stabilized by feedback. A feedback loop consists of an error amplifier, a voltage controlled oscillator and a driver circuit. The amplitude ratio of the transformer has dependence on the frequency, which is utilized to stabilize the output voltage. The low voltage power supply is investigated on the analogy of the high voltage power supply similarly incorporating the cerami...

  17. Tap Water Hydraulic Systems for Medium Power Applications

    DEFF Research Database (Denmark)

    Conrad, Finn; Adelstorp, Anders

    1998-01-01

    Presentation of new range of developed tap water hydraulic componets and applications for medium power up to 4 kW and 50 bar.......Presentation of new range of developed tap water hydraulic componets and applications for medium power up to 4 kW and 50 bar....

  18. 49 CFR 236.516 - Power supply.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Power supply. 236.516 Section 236.516..., Train Control and Cab Signal Systems Standards § 236.516 Power supply. Automatic cab signal, train stop, or train control device hereafter installed shall operate from a separate or isolated power...

  19. Simplified design of switching power supplies

    CERN Document Server

    Lenk, John

    1995-01-01

    * Describes the operation of each circuit in detail * Examines a wide selection of external components that modify the IC package characteristics * Provides hands-on, essential information for designing a switching power supply Simplified Design of Switching Power Supplies is an all-inclusive, one-stop guide to switching power-supply design. Step-by-step instructions and diagrams render this book essential for the student and the experimenter, as well as the design professional. Simplified Design of Switching Power Supplies concentrates on the use of IC regulators. All popular forms of swit

  20. THE CONCEPT OF UNINTERRUPTED POWER SUPPLY SYSTEMS

    Directory of Open Access Journals (Sweden)

    Grigorash O. V.

    2016-05-01

    Full Text Available We have revealed the main reasons for interruptions in power supply to consumers of electricity. To improve the reliability and the efficiency of power supply for responsible consumers, we have proposed to develop energy efficient combined energy-saving systems for uninterrupted power supply with use of renewable energy sources. The article lists major principles of the development of such systems; it shows the necessity of constructing a generalized schema that contains the possible types and the sources of electric power converters. It also reveals the modern requirements to systems of uninterrupted energy supply. To improve the operational and technical characteristics of the uninterruptible power supply, it has been proposed to use a new circuitry that includes a contactless power generators, the direct frequency converters used to stabilize the voltage and frequency of the current generators of wind turbines, static converters made with the use of single-phase transformers with rotating magnetic field, universal static converters that can operate in the regimes of known types of converters. The article presents features of the modular construction of systems of uninterrupted energy supply and optimization of their structural decisions on key performance criteria. It shows the algorithm of synthesis of structural designs of combined systems of uninterrupted power supply. An important step for further research with the aim of improving operational and technical characteristics of the combination of uninterrupted power supply systems is the mathematical modeling of physical processes in power circuits of the system in both normal and emergency modes of operation

  1. Simplified design of switching power supplies

    CERN Document Server

    Lenk, John

    1996-01-01

    Simplified Design of Switching Power Supplies is an all-inclusive, one-stop guide to switching power-supply design. Step-by-step instructions and diagrams render this book essential for the student and the experimenter, as well as the design professional.Simplified Design of Switching Power Supplies concentrates on the use of IC regulators. All popular forms of switching supplies, including DC-DC converters, inverters, buck, boost, buck-boost, pulse frequency modulation, pulse width modulation, current-mode control and pulse skipping, are described in detail. The design examples may

  2. 46 CFR 169.688 - Power supply.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Power supply. 169.688 Section 169.688 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS Machinery and Electrical Electrical Installations on Vessels of 100 Gross Tons and Over § 169.688 Power supply. (a)...

  3. High Power Amplifier and Power Supply

    Science.gov (United States)

    Duong, Johnny; Stride, Scot; Harvey, Wayne; Haque, Inam; Packard, Newton; Ng, Quintin; Ispirian, Julie Y.; Waian, Christopher; Janes, Drew

    2008-01-01

    A document discusses the creation of a high-voltage power supply (HVPS) that is able to contain voltages up to -20 kV, keep electrical field strengths to below 200 V/mil (approximately equal to 7.87 kV/mm), and can provide a 200-nanosecond rise/fall time focus modulator swinging between cathode potential of 16.3 kV and -19.3 kV. This HVPS can protect the 95-GHz, pulsed extended interaction klystron (EIK) from arcs/discharges from all sources, including those from within the EIK fs vacuum envelope. This innovation has a multi-winding pulse transformer design, which uses new winding techniques to provide the same delays and rise/fall times (less than 10 nanoseconds) at different potential levels ranging from -20 kV to -16 kV. Another feature involves a high-voltage printed-wiring board that was corona-free at -20 kV DC with a 3- kV AC swing. The corona-free multilayer high-voltage board is used to simulate fields of less than 200 V/mil (approximately equal to 7.87 kV/mm) at 20 kV DC. Drive techniques for the modulator FETs (field-effect transistors) (four to 10 in a series) were created to change states (3,000-V swing) without abrupt steps, while still maintaining required delays and transition times. The packing scheme includes a potting mold to house a ten-stage modulator in the space that, in the past, only housed a four-stage modulator. Problems keeping heat down were solved using aluminum oxide substrate in the high-voltage section to limit temperature rise to less than 10 while withstanding -20 kV DC voltage and remaining corona-free.

  4. Wireless Power Transmission for Power Supply: State of Art

    OpenAIRE

    2011-01-01

    The wireless power supply is motivated by simple and comfortable use of many small electric appliances with low power input. This paper reviews the concepts which are suitable for wireless power transmission with respect to power supply of such appliances in small areas. The categorization of the concepts is made. The efficiency of the concepts is discussed on general base. The reference levels for exposure to electric and magnetic fields are mentioned, and maximal power delivered to an appli...

  5. Active Rectifier for Uninterruptable Power Supply

    Science.gov (United States)

    Stepanov, Andrew; Bogdans, Valdis; Suskis, Pavel; Galkin, Ilya

    2010-01-01

    The paper contains analysis of power factor correction circuits that is made in the context of elaboration of uninterruptable power supply system. Various correctors have been estimated analytically, by means of simulation and experimentally. The most significant attention has been paid to the efficiency of the analyzed converters and their compatibility with modular approach to development of power converters.

  6. Discrete Displacement Hydraulic Power Take-Off System for the Wavestar Wave Energy Converter

    DEFF Research Database (Denmark)

    Hansen, Rico Hjerm; Kramer, Morten; Vidal, Enrique

    2013-01-01

    The Wavestar Wave Energy Converter (WEC) is a multiple absorber concept, consisting of 20 hemisphere shaped floats attached to a single platform. The heart of the Wavestar WEC is the Power Take-Off (PTO) system, converting the wave induced motion of the floats into a steady power output to the grid....... In the present work, a PTO based on a novel discrete displacement fluid power technology is explored for the Wavestar WEC. Absorption of power from the floats is performed by hydraulic cylinders, supplying power to a common fixed pressure system with accumulators for energy smoothing. The stored pressure energy...

  7. Design of ITER NBI power supply system

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Kazuhiro; Ohara, Yoshihiro; Okumura, Yoshikazu [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment; Higa, Osamu; Kawashima, Syuichi; Ono, Youichi; Tanaka, Masanobu; Yasutomi, Sei

    1997-07-01

    Power supply system for the ITER neutral beam injector (NBI) whose total injection power is 1 MeV, 50 MW from three modules, has been designed. The power supply system consists of a source power supply for negative ion production/extraction and a DC 1 MV, 45 A power supply for negative ion acceleration. An inverter controlled multi-transformer/rectifier system has been adopted to the acceleration power supply. An inverter frequency of 150 Hz was selected to satisfy required specifications which are rise time of <100 ms, voltage ripple of <10% peak to peak and cut off speed of <200{mu}s. It was confirmed that the rise time, the ripple and the cut off speed is about 50 ms, 7% and <200{mu}s respectively by computation. It was also confirmed that a surge current and an energy input to the ion source at the breakdown can be suppressed lower than 3 kA and 10 J, which are considered to be lower than allowable values. A 1 MV transmission line has been designed from a view point of electric field on the inner conductors and grounded conductor. The results from the design study indicate that all the required specification to the power supply system can be satisfied and that R and D on the transmission line is one of the most important subjects. (author)

  8. ENERGY STAR Certified Uninterruptible Power Supplies

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 1.0 ENERGY STAR Program Requirements for Uninterruptible Power Supplies that are...

  9. SOURCES OF UNINTERRUPTED AND AUTONOMOUS POWER SUPPLY

    Directory of Open Access Journals (Sweden)

    Denisenko E. A.

    2016-01-01

    Full Text Available The article describes the main block diagrams of three types of uninterruptible power supply: backup; interactive; double conversion. The main functions are: the function backup or emergency source of electrical power; the function of protective devices (from an overload currents and short-circuit; improving the quality of the power supply voltage. Alsoб we have disclosed the features of the advantages and disadvantages of uninterruptible power supplies three groups: Off-Line / Stand-By / back-up UPS (passive - reserve; Line-Interactive (line interactive type; On-Line. The article discloses new approaches to structural and schematic-based uninterruptible power supply, including at use of renewable energy, so that the failure of one of the sources does not lead to exit from the operation of the entire of power supply system. As a rule, such systems are built on a modular principle. It is shown that now for remote users from external networks is advisable to apply a system autonomous power supply, representing the totality of sources and converters of electric power, ensuring uninterrupted power supply to consumers. We have presented a typical structure of autonomous systems and given an option of the block diagram of the system and are given explanations and principles of its work. Significantly improves performance reliability of autonomous systems using the modularity of its main functional units. In addition, to increase the efficiency of the system can be through the use in the construction of transformers with static converters rotating magnetic field. To improve the weight, which is important for the transport systems, it is necessary to use links with the intermediate high-frequency electric power conversion in static converters

  10. Innovative use of power integrated modules for DC power supplies

    DEFF Research Database (Denmark)

    Ørndrup Nielsen, Rasmus; Elkiær, Alexander; Munk-Nielsen, Stig;

    2013-01-01

    In this article several innovative ways of utilizing Power Integrated Modules (PIM) as switching device in a DC power supply are presented. PIM have advantages in compactness of design, cost and fast prototype due to easier PCB layout. A PIM converter topology is chosen and designed resulting...... in an experimental setup. Results from the setup are presented showing the feasibility of using a PIM module as almost all power semiconductors in a DC power supply....

  11. Innovative power supply concepts for DBD excilamps

    Science.gov (United States)

    Piquet, Hubert; Bhosle, Sounil; Díez, Rafael; Toumi, Areski; Zissis, Georges

    2008-01-01

    Excimer and exciplex UV/VUV sources excited by Dielectric Barrier Discharges represent a promising technology for industrial applications where powerful and efficient UV sources are needed. According to previous work, the most suited power supply waveform for coaxial DBD Excilamps is a unipolar pulsed voltage excitation of some kilovolts at some hundred of kilohertz with a duty cycle around one percent. We present here new concepts for energy supplying of coaxial DBDs, based on the direct control of the current in the lamps. These concepts have been tested by means of simulation models developed in our department and the time evolution of the UV radiation is presented for various considered current waveforms. Based on these results, a power supply topology has been designed for an efficient power transfer to the Excilamp. It is based on a converter which controls the current flowing through the DBD. The results concerning the coupling of this converter with a DBD load are commented.

  12. Smart Power Supply for Battery-Powered Systems

    Science.gov (United States)

    Krasowski, Michael J.; Greer, Lawrence; Prokop, Norman F.; Flatico, Joseph M.

    2010-01-01

    A power supply for battery-powered systems has been designed with an embedded controller that is capable of monitoring and maintaining batteries, charging hardware, while maintaining output power. The power supply is primarily designed for rovers and other remote science and engineering vehicles, but it can be used in any battery alone, or battery and charging source applications. The supply can function autonomously, or can be connected to a host processor through a serial communications link. It can be programmed a priori or on the fly to return current and voltage readings to a host. It has two output power busses: a constant 24-V direct current nominal bus, and a programmable bus for output from approximately 24 up to approximately 50 V. The programmable bus voltage level, and its output power limit, can be changed on the fly as well. The power supply also offers options to reduce the programmable bus to 24 V when the set power limit is reached, limiting output power in the case of a system fault detected in the system. The smart power supply is based on an embedded 8051-type single-chip microcontroller. This choice was made in that a credible progression to flight (radiation hard, high reliability) can be assumed as many 8051 processors or gate arrays capable of accepting 8051-type core presently exist and will continue to do so for some time. To solve the problem of centralized control, this innovation moves an embedded microcontroller to the power supply and assigns it the task of overseeing the operation and charging of the power supply assets. This embedded processor is connected to the application central processor via a serial data link such that the central processor can request updates of various parameters within the supply, such as battery current, bus voltage, remaining power in battery estimations, etc. This supply has a direct connection to the battery bus for common (quiescent) power application. Because components from multiple vendors may have

  13. Efficient chaotic based satellite power supply subsystem

    Energy Technology Data Exchange (ETDEWEB)

    Ramos Turci, Luiz Felipe [Technological Institute of Aeronautics (ITA), Sao Jose dos Campos, SP (Brazil)], E-mail: felipeturci@yahoo.com.br; Macau, Elbert E.N. [National Institute of Space Research (Inpe), Sao Jose dos Campos, SP (Brazil)], E-mail: elbert@lac.inpe.br; Yoneyama, Takashi [Technological Institute of Aeronautics (ITA), Sao Jose dos Campos, SP (Brazil)], E-mail: takashi@ita.br

    2009-10-15

    In this work, we investigate the use of the Dynamical System Theory to increase the efficiency of the satellite power supply subsystems. The core of a satellite power subsystem relies on its DC/DC converter. This is a very nonlinear system that presents a multitude of phenomena ranging from bifurcations, quasi-periodicity, chaos, coexistence of attractors, among others. The traditional power subsystem design techniques try to avoid these nonlinear phenomena so that it is possible to use linear system theory in small regions about the equilibrium points. Here, we show that more efficiency can be drawn from a power supply subsystem if the DC/DC converter operates in regions of high nonlinearity. In special, if it operates in a chaotic regime, is has an intrinsic sensitivity that can be exploited to efficiently drive the power subsystem over high ranges of power requests by using control of chaos techniques.

  14. Evolution of Very High Frequency Power Supplies

    DEFF Research Database (Denmark)

    Knott, Arnold; Andersen, Toke Meyer; Kamby, Peter

    2013-01-01

    in radio frequency transmission equipment helps to overcome those. However those circuits were not designed to meet the same requirements as power converters. This paper summarizes the contributions in recent years in application of very high frequency (VHF) technologies in power electronics, shows results......The ongoing demand for smaller and lighter power supplies is driving the motivation to increase the switching frequencies of power converters. Drastic increases however come along with new challenges, namely the increase of switching losses in all components. The application of power circuits used...

  15. Automated Hydraulic System Design and Power Management in Mobile Applications

    DEFF Research Database (Denmark)

    Pedersen, Henrik Clemmensen

    a presentation of the used graph theory representation that is developed to represent a hydraulic open-circuit system and which is based on a numerical formulation that uniquely describe the system in terms of five set of design variables that describe respectively the topology, the components and the operating...... are found on most medium and high-end mobile hydraulic machinery. Despite the energy saving potentials that these systems posses, compared to the other open-circuit hydraulic system topologies, LS-system may still be subject to very low system efficiencies if not designed correctly. This is typically...... machines if operated in the intended and optimal work area, but due to an inappropriate system layout. Most of the power lost in open circuit hydraulic system systems is in this regard in the transmission part, i.e. hoses and fittings, and the valves used to control the system. A large part of the design...

  16. Stabilized DC power supplies; Alimentations continues stabilisees

    Energy Technology Data Exchange (ETDEWEB)

    Boutouyrie, B. [Ecole Superieure d' Electricite, 91 - Gif-sur-Yvette (France)

    2002-05-01

    This article deals with DC power supplies devoted to electronic equipments with a power comprised between 10 W to 5000 W with a AC (50 Hz to 400 Hz) or a DC input and one or several DC outputs of 200 V maximum. The broad outlines of the main technical problems are presented and a particular care is given to the parameters interesting for user's applications: 1 - principles (in-series regulation and switching power supplies); 2 - noise in switching power supplies (disturbances transferred by conductors and frame, radio-frequency noise, noise measurement, output waveform); 3 - disturbances standardization (classes, regulation and label, standards); 4 - mean time between failure (MTBF) and reliability (calculated or demonstrated MTBF, reliability, reliability-limiting components, new test and burn-in methods); 5 - efficiency and cooling; 6 - applications (input current, sense, decoupling, current limitation, in-parallel installation, redundancy, battery charging, use with inductive load, power factor correction, modular power supplies); 7 - some advices. (J.S.)

  17. Calculation of Water Supply to Hydraulic Jet Devices

    Directory of Open Access Journals (Sweden)

    M. V. Krautsou

    2006-01-01

    Full Text Available Dependence for calculation of working fluid supply to water-air ejector is proposed. The de­pendence has been derived via analysis and processing of data being obtained by experimental research of water-jet devices.

  18. 49 CFR 236.551 - Power supply voltage; requirement.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Power supply voltage; requirement. 236.551 Section... supply voltage; requirement. The voltage of power supply shall be maintained within 10 percent of rated voltage....

  19. A hydraulic distribution device of a powered support section

    Energy Technology Data Exchange (ETDEWEB)

    Zhuravlev, R.P.; Barinov, V.S.; Demidovich, Z.A.; Fedorov, L.I.; Kozhukhov, L.F.; Mosunov, Yu.Ya.

    1981-01-30

    The goal of this invention is to reduce the working time for manual control in the process of bracing a hydraulic prop and complete use of the working pressure of the support's hydraulic system to perform initial bracing of the hydraulic prop. To achieve this goal, the device has a reflux valve with a locking element and a choke, the latter situated between the piston and rod chambers; the floating piston is made with a stop which interacts with the motion limiter, while the rod of the floating piston has a pusher which interacts with the locking element of the reflux valve. Use of the hydraulic device of this design in powered supports during their operation under various mining conditions significantly raises the operating life of hydraulic supports and hydraulic distributors, while lowering the total complex's down time. Automatic positioning of the predetermined amount of initial spacing shortens the time in which the operator handles the support sections. The operator uses the time available to perform succeeding operations (transition to the next control panel, unloading, and transfer).

  20. Power enhancement of piezoelectric transformers for power supplies

    DEFF Research Database (Denmark)

    Ekhtiari, Marzieh; Steenstrup, Anders Resen; Zhang, Zhe

    2016-01-01

    This paper studies power enhancement of piezoelectric transformers to be used in inductorless, half-bridge, piezoelecteric-based switch mode power supplies for driving a piezo actuator motor system in a high strength magnetic environment for magnetic resonance imaging and computed tomography...... applications. A new multi element-piezo transformer solution is proposed along with a dual mode piezo transformer, providing power scaling and potentially improving the internal heat-up of a high power piezo transformer system....

  1. Schedule Planning for Repairing Power Supply System

    OpenAIRE

    Kuo-Wei Lin; Chein-Jen Kang

    2012-01-01

    Problem statement: Taiwan is located in the tropical ocean areas. The strong typhoon in summer often causes the collapse of electric transmission towers and results in power outages that seriously affect peoples lives and industrial production. Approach: In light of this situation, this study aims to employ project management techniques of Theory of Constraints (TOC) to develop a practical TOC model to quickly repair the towers and restore power supplied system. Results: The actual applicatio...

  2. Novel Reduced Parts Online Uninterruptible Power Supply

    OpenAIRE

    Bahram Ashrafi; Mehdi Niroomand

    2012-01-01

    This paper presents design consideration and performance analysis of novel reduced parts online three-phase uninterruptible power supply (UPS) system. The proposed UPS system is based on reduced switch count dual bridge matrix converter. It employs only six power switches and results in reducing the cost of the system compared to conventional online UPS topologies, while achieving excellent performance. The performance of the proposed system is evaluated through simulation in terms of input/o...

  3. Solid state capacitor discharge pulsed power supply for railguns

    OpenAIRE

    2007-01-01

    This thesis presents a solid state thyristor switched power supply capable of providing 50 kJ from a high voltage capacitor to a railgun. The efficiency with which energy is transferred from a power supply to a projectile depends strongly on power supply characteristics. This design will provide a better impedance match to the railgun than power supplies utilizing spark gap switches. This supply will cost less and take up less volume than a similar supply using spark gap switches; it wil...

  4. Dual voltage power supply with 48 volt

    Energy Technology Data Exchange (ETDEWEB)

    Froeschl, Joachim; Proebstle, Hartmut; Sirch, Ottmar [BMW Group, Muenchen (Germany)

    2012-11-01

    Automotive electrics/electronics have just reached a period of tremendous change. High voltage systems for Hybrid, Plug-In Hybrid or Battery Electric Vehicles with high power electric motors, high energy accumulators and electric climate compressors will be introduced in order to achieve the challenging targets for CO{sub 2} emissions and energy efficiency and to anticipate the mobility of the future. Additionally, innovations and the continuous increase of functionality for comfort, safety, driver assistance and infotainment systems require more and more electrical power of the vehicle power supply at all. On the one hand side electrified vehicles will certainly achieve a significant market share, on the other hand side they will increase the pressure to conventional vehicles with combustion engines for fuel consumption and CO{sub 2} emissions. These vehicles will be enabled to keep their competitiveness by new functions and the optimization of their electric systems. A dual voltage power supply with 48 Volt and 12 Volt will be one of the key technologies to realize these requirements. The power capability of the existing 12 Volt power supply has reached its limits. Further potentials can only be admitted by the introduction of 48 Volt. For this reason the car manufacturers Audi, BMW, Daimler, Porsche and Volkswagen started very early on this item and developed a common specification of the new voltage range. Now, it is necessary to identify the probable systems at this voltage range and to start the developments. (orig.)

  5. 24 CFR 3280.803 - Power supply.

    Science.gov (United States)

    2010-04-01

    ... must be suitable for use in wet locations; (iii) Each neutral conductor must be connected to the system... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Power supply. 3280.803 Section 3280.803 Housing and Urban Development Regulations Relating to Housing and Urban Development (Continued...

  6. Hydraulic fluid used for power transmission

    Energy Technology Data Exchange (ETDEWEB)

    Heikkilae, M.; Pikulinsky, K.; Leisio, C.

    1996-11-01

    In early October another 50-kilowatt wind turbine was provided with new power transmission technology at the Kopparnaes Energy Park in Inkoo, Finland, west of Helsinki. The new technology is thought to make this wind turbine located on the south coast of Finland more efficient, lighter, and cheaper. Certain aspects of this new technology can be applied to older wind turbines. (orig.)

  7. Hydraulic fluid used for power transmission

    Energy Technology Data Exchange (ETDEWEB)

    Heikkilae, M.; Pikulinsky, K.; Leisio, C.

    1996-11-01

    In early October another 50-kilowatt wind turbine was provided with new power transmission technology at the Kopparnaes Energy Park in Inkoo, Finland, west of Helsinki. The new technology is thought to make this wind turbine located on the south coast of Finland more efficient, lighter, and cheaper. Certain aspects of this new technology can be applied to older wind turbines. (orig.)

  8. Automated Hydraulic System Design and Power Management in Mobile Applications

    DEFF Research Database (Denmark)

    Pedersen, Henrik Clemmensen

    machines if operated in the intended and optimal work area, but due to an inappropriate system layout. Most of the power lost in open circuit hydraulic system systems is in this regard in the transmission part, i.e. hoses and fittings, and the valves used to control the system. A large part of the design...... are working under the most optimal operating conditions. The above in this way constitute the background for the work that is the basis of this report, which deals with how to design and control open-circuit hydraulic systems with multiple consumers to obtain the largest energy utilization, when also...... a presentation of the used graph theory representation that is developed to represent a hydraulic open-circuit system and which is based on a numerical formulation that uniquely describe the system in terms of five set of design variables that describe respectively the topology, the components and the operating...

  9. Low-power microfluidic electro-hydraulic pump (EHP).

    Science.gov (United States)

    Lui, Clarissa; Stelick, Scott; Cady, Nathaniel; Batt, Carl

    2010-01-07

    Low-power electrolysis-based microfluidic pumps utilizing the principle of hydraulics, integrated with microfluidic channels in polydimethylsiloxane (PDMS) substrates, are presented. The electro-hydraulic pumps (EHPs), consisting of electrolytic, hydraulic and fluidic chambers, were investigated using two types of electrodes: stainless steel for larger volumes and annealed gold electrodes for smaller-scale devices. Using a hydraulic fluid chamber and a thin flexible PDMS membrane, this novel prototype successfully separates the reagent fluid from the electrolytic fluid, which is particularly important for biological and chemical applications. The hydraulic advantage of the EHP device arises from the precise control of flow rate by changing the electrolytic pressure generated, independent of the volume of the reagent chamber, mimicking the function of a hydraulic press. Since the reservoirs are pre-filled with reagents and sealed prior to testing, external fluid coupling is minimized. The stainless steel electrode EHPs were manufactured with varying chamber volume ratios (1 : 1 to 1 : 3) as a proof-of-concept, and exhibited flow rates of 1.25 to 30 microl/min with electrolysis-based actuation at 2.5 to 10 V(DC). The miniaturized gold electrode EHPs were manufactured with 3 mm diameters and 1 : 1 chamber volume ratios, and produced flow rates of 1.24 to 7.00 microl/min at 2.5 to 10 V(AC), with a higher maximum sustained pressure of 343 KPa, suggesting greater device robustness using methods compatible with microfabrication. The proposed technology is low-cost, low-power and disposable, with a high level of reproducibility, allowing for ease of fabrication and integration into existing microfluidic lab-on-a-chip and analysis systems.

  10. Power Supplies for High Energy Particle Accelerators

    Science.gov (United States)

    Dey, Pranab Kumar

    2016-06-01

    The on-going research and the development projects with Large Hadron Collider at CERN, Geneva, Switzerland has generated enormous enthusiasm and interest amongst all to know about the ultimate findings on `God's Particle'. This paper has made an attempt to unfold the power supply requirements and the methodology adopted to provide the stringent demand of such high energy particle accelerators during the initial stages of the search for the ultimate particles. An attempt has also been made to highlight the present status on the requirement of power supplies in some high energy accelerators with a view that, precautionary measures can be drawn during design and development from earlier experience which will be of help for the proposed third generation synchrotron to be installed in India at a huge cost.

  11. International Space Station power module thermal control system hydraulic performance

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, V. [Boeing North American, Inc., Canoga Park, CA (United States). Rocketdyne Div.

    1997-12-31

    The International Space Station (ISS) uses four photovoltaic power modules (PVMs) to provide electric power for the US On-Orbit Segment. The PVMs consist of photovoltaic arrays (PVAs), orbit replaceable units (ORUs), photovoltaic radiators (PVRs), and a thermal control system (TCS). The PVM TCS function is to maintain selected PVM components within their specified operating ranges. The TCS consists of the pump flow control subassembly (PFCS), piping system, including serpentine tubing for individual component heat exchangers, headers/manifolds, fluid disconnect couplings (FQDCs), and radiator (PVR). This paper describes the major design requirements for the TCS and the results of the system hydraulic performance predictions in regard to these requirements and system component sizing. The system performance assessments were conducted using the PVM TCS fluid network hydraulic model developed for predicting system/component pressure losses and flow distribution. Hardy-Cross method of iteration was used to model the fluid network configuration. Assessments of the system hydraulic performance were conducted based on an evaluation of uncertainties associated with the manufacturing and design tolerances. Based on results of the analysis, it was concluded that all design requirements regarding system performance could be met. The hydraulic performance range, enveloping possible system operating parameter variations was determined.

  12. Hydraulics.

    Science.gov (United States)

    Decker, Robert L.; Kirby, Klane

    This curriculum guide contains a course in hydraulics to train entry-level workers for automotive mechanics and other fields that utilize hydraulics. The module contains 14 instructional units that cover the following topics: (1) introduction to hydraulics; (2) fundamentals of hydraulics; (3) reservoirs; (4) lines, fittings, and couplers; (5)…

  13. Novel Reduced Parts Online Uninterruptible Power Supply

    Directory of Open Access Journals (Sweden)

    Bahram Ashrafi

    2012-01-01

    Full Text Available This paper presents design consideration and performance analysis of novel reduced parts online three-phase uninterruptible power supply (UPS system. The proposed UPS system is based on reduced switch count dual bridge matrix converter. It employs only six power switches and results in reducing the cost of the system compared to conventional online UPS topologies, while achieving excellent performance. The performance of the proposed system is evaluated through simulation in terms of input/output waveforms quality and shows the viability of topology.

  14. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Hydraulic or pneumatic power and control-materials and... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component (such as pipe runs, fittings, flanges, and standard valves) for hydraulic or pneumatic power and...

  15. 49 CFR 173.172 - Aircraft hydraulic power unit fuel tank.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Aircraft hydraulic power unit fuel tank. 173.172 Section 173.172 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS... Class 1 and Class 7 § 173.172 Aircraft hydraulic power unit fuel tank. Aircraft hydraulic power...

  16. 46 CFR 113.10-9 - Power supply.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Power supply. 113.10-9 Section 113.10-9 Shipping COAST... SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-9 Power supply. (a) General... battery, the charger must be supplied from the final emergency power source. Upon loss of power to...

  17. Powered orthosis and attachable power-assist device with Hydraulic Bilateral Servo System.

    Science.gov (United States)

    Ohnishi, Kengo; Saito, Yukio; Oshima, Toru; Higashihara, Takanori

    2013-01-01

    This paper discusses the developments and control strategies of exoskeleton-type robot systems for the application of an upper limb powered orthosis and an attachable power-assist device for care-givers. Hydraulic Bilateral Servo System, which consist of a computer controlled motor, parallel connected hydraulic actuators, position sensors, and pressure sensors, are installed in the system to derive the joint motion of the exoskeleton arm. The types of hydraulic component structure and the control strategy are discussed in relation to the design philosophy and target joints motions.

  18. Hydraulic and biochemical gradients limit wetland mercury supply to an Adirondack stream

    Science.gov (United States)

    Bradley, Paul M.; Burns, Douglas A.; Harvey, Judson; Journey, Celeste A.; Brigham, Mark E.; Murray, Karen

    2016-01-01

    Net fluxes (change between upstream and downstream margins) for water, methylmercury (MeHg), total mercury (THg), dissolved organic carbon (DOC), and chloride (Cl) were assessed twice in an Adirondack stream reach (Sixmile Brook, USA), to test the hypothesized importance of wetland-stream hydraulic and chemical gradients as fundamental controls on fluvial mercury (Hg) supply. The 500 m study reach represented less than 4% of total upstream basin area. During a snowmelt high-flow event in May 2009 surface water, DOC, and chloride fluxes increased by 7.1±1.3%, 8.0±1.3%, and 9.0±1.3%, respectively, within the reach, demonstrating that the adjacent wetlands are important sources of water and solutes to the stream. However, shallow groundwater Hg concentrations lower than in the surface water limited groundwater-surface water Hg exchange and no significant changes in Hg (filtered MeHg and THg) fluxes were observed within the reach despite the favorable hydraulic gradient. In August 2009, the lack of significant wetland-stream hydraulic gradient resulted in no net flux of water or solutes (MeHg, THg, DOC, or Cl) within the reach. The results are consistent with the wetland-Hg-source hypothesis and indicate that hydraulic and chemical gradient (direction and magnitude) interactions are fundamental controls on the supply of wetland Hg to the stream.

  19. Ultracapacitor-Based Uninterrupted Power Supply System

    Science.gov (United States)

    Eichenberg, Dennis J.

    2011-01-01

    The ultracapacitor-based uninterrupted power supply (UPS) system enhances system reliability; reduces life-of-system, maintenance, and downtime costs; and greatly reduces environmental impact when compared to conventional UPS energy storage systems. This design provides power when required and absorbs power when required to smooth the system load and also has excellent low-temperature performance. The UPS used during hardware tests at Glenn is an efficient, compact, maintenance-free, rack-mount, pure sine-wave inverter unit. The UPS provides a continuous output power up to 1,700 W with a surge rating of 1,870 W for up to one minute at a nominal output voltage of 115 VAC. The ultracapacitor energy storage system tested in conjunction with the UPS is rated at 5.8 F. This is a bank of ten symmetric ultracapacitor modules. Each module is actively balanced using a linear voltage balancing technique in which the cell-to-cell leakage is dependent upon the imbalance of the individual cells. The ultracapacitors are charged by a DC power supply, which can provide up to 300 VDC at 4 A. A constant-voltage, constant-current power supply was selected for this application. The long life of ultracapacitors greatly enhances system reliability, which is significant in critical applications such as medical power systems and space power systems. The energy storage system can usually last longer than the application, given its 20-year life span. This means that the ultracapacitors will probably never need to be replaced and disposed of, whereas batteries require frequent replacement and disposal. The charge-discharge efficiency of rechargeable batteries is approximately 50 percent, and after some hundreds of charges and discharges, they must be replaced. The charge-discharge efficiency of ultracapacitors exceeds 90 percent, and can accept more than a million charges and discharges. Thus, there is a significant energy savings through the efficiency improvement, and there is far less

  20. POWERED LED LIGHTING SUPPLIED FROM PV CELLS

    Directory of Open Access Journals (Sweden)

    Tirshu M.

    2011-12-01

    Full Text Available The paper deals with practical realization of efficient lighting system based on LED’s of 80W total power mounted on corridor ceiling total length of which is 120m and substitutes existing traditional lighting system consisting of 29 lighting blocks with 4 fluorescent lamps each of them and summary power 2088W. Realized lighting system is supplied from two photovoltaic panels of power 170W. Generated energy by PV cells is accumulated in two accumulators of 75Ah capacity and from battery by means of specialized convertor is applied to lighting system. Additionally, paper present data measured by digital weather station (solar radiation and UV index, which is mounted near of PV cells and comparative analyze of solar energy with real energy generated by PV cells is done. Measured parameters by digital weather station are stored by computer in on-line mode.

  1. DC power supplies power management and surge protection for power electronic systems

    CERN Document Server

    Kularatna, Nihal

    2011-01-01

    Modern electronic systems, particularly portable consumer electronic systems and processor based systems, are power hungry, compact, and feature packed. This book presents the most essential summaries of the theory behind DC-DC converter topologies of both linear and switching types. The text discusses power supply characteristics and design specifications based on new developments in power management techniques and modern semiconductors entering into the portable electronics market. The author also addresses off-the-line power supplies, digital control of power supply, power supply protection

  2. Fuel-cell powered uninterruptible power supply systems: Design considerations

    Science.gov (United States)

    Choi, Woojin; Howze, Jo. W.; Enjeti, Prasad

    A 1-kVA fuel cell powered, line-interactive uninterruptible power supply (UPS) system that employs modular (fuel cell and power converter) blocks is introduced. Two commercially available proton-exchange membrane fuel cell (25-39 V, 500 W) modules together with suitable dc-dc and dc-ac power electronic converter modules are employed. A supercapacitor module is also used to compensate for the instantaneous power fluctuations and to overcome the slow dynamics of the fuel processor (reformers). Further energy stored in the supercapacitor is also utilized to handle a momentary overload such as 200% for a short duration. Due to the absence of batteries, the system satisfies the demand for an environmentally clean source of energy. A complete design that defines the amount of hydrogen storage required for a power outage of 1 h, and the sizing of the supercapacitors for transient load demand is presented for a 1-kVA UPS.

  3. TIG welding power supply with improved efficiency

    Directory of Open Access Journals (Sweden)

    Сергій Володимирович Гулаков

    2015-03-01

    Full Text Available In the article, the influence of the DC component of the welding current during TIG (Tungsten Inert Gas welding is discussed. Known methods of DC current cancellation are reviewed, such as capacitor bank or diode/thyristor network insertion in the secondary circuit of the welding transformer. A new method of controlling the magnitude and shape of the TIG welding current is proposed. The idea is to insert a controlled voltage source in the secondary circuit of the welding transformer. This controlled voltage source is realized using a full-bridge voltage source inverter (VSI. VSI control system design issues are discussed. VSI is controlled by a three-level hysteretic current controller, while current reference is generated using lookup table driven by PLL (Phase Locked Loop locked to the mains frequency. Simulation results are shown. The proposed topology of TIG power supply allows to provide magnitude and shape control of the welding current, with the limitation that its DC component must be zero. Thus, some capabilities of professional AC-TIG welders are obtained using substantially lower cost components: VSI built using high-current low voltage MOSFETs with control system based on 32-bit ARM microcontroller. The use of proposed TIG welding power supply will eliminate the DC component of the welding current, improve welding transformer’s power factor and improve welding technology by increasing the welding arc stability

  4. Fault tolerant system design for uninterruptible power supplies

    OpenAIRE

    B. Y. Volochiy; D. S. Kuznetsov

    2012-01-01

    The problem of design for reliability of a fault tolerant system for uninterruptible power supplies is considered. Configuration of a fault tolerant system determines the structure of an uninterruptible power supply: power supply built from modules of the same type, stand-by sliding reserve for them, twice total reserve of the power supply with two accumulator batteries, the controls and diagnostics means. The developed tool for automated analytical model of fault tolerant systems generation ...

  5. Improving Electrical Efficiency of Edm Power Supply

    Science.gov (United States)

    Toma, Emanoil; Simion, Carmen Mihaela

    2014-11-01

    This paper briefly presents the principal types of Pulse Generators for Electrical Discharge Machining and ways to improve electrical efficiency. A resonant converter with series-parallel LCC circuit, for EDM applications, was analyzed by PSpice simulation. The performances of EDM Power Supply were improved by adding an energy recovering - voltage limiter circuit. The shape of current pulse was changed by adding a supplementary MOSFET Switch in parallel with the gap. Two or more converters can be parallelized, in this way output current can be changed. A bloc-schema was conceived for EDM experimental set up

  6. Westinghouse programs in pulsed homopolar power supplies

    Science.gov (United States)

    Litz, D. C.; Mullan, E.

    1984-01-01

    This document details Westinghouse's ongoing study of homopolar machines since 1929 with the major effort occurring in the early 1970's to the present. The effort has enabled Westinghouse to develop expertise in the technology required for the design, fabrication and testing of such machines. This includes electrical design, electromagnetic analysis, current collection, mechanical design, advanced cooling, stress analysis, transient rotor performance, bearing analysis and seal technology. Westinghouse is using this capability to explore the use of homopolar machines as pulsed power supplies for future systems in both military and commercial applications.

  7. Ablation response testing of aerospace power supplies

    Science.gov (United States)

    Lutz, S. A.; Chan, C. C.

    1993-01-01

    An experimental program was performed to assess the aerothermal ablation response of aerospace power supplies. Full-scale General Purpose Heat Source (GPHS) test articles, Graphite Impact Shell (GIS) test articles, and Lightweight Radioisotope Heater Unit (LWRHU) test articles were all tested without nuclear fuel in simulated reentry environments at the NASA Ames Research Center. Stagnation heating, stagnation pressure, stagnation surface temperature, stagnation surface recession profile, and weight loss measurements were obtained for diffusion-limited and sublimation ablation conditions. The recession profile and weight loss measurements showed an effect of surface features on the stagnation face. The surface features altered the local heating which in turn affected the local ablation.

  8. Preferred external power supplies; Fuentes electricas preferentes exteriores

    Energy Technology Data Exchange (ETDEWEB)

    Martinez Anton, L.

    2010-07-01

    In June 2008 ANAV and ENDESA DISTRIBUCION (EDE) undertook a joint study of Asco NPP Preferred External Power Supplies (PEPSs) to check the number of lines or power supplies to the 110 kV substation at Asco that met the criteria defined in the power supply regulations applicable to Asco NPP and primarily to confirm compliance with IEEE 765-2006 standard. (Author).

  9. Schedule Planning for Repairing Power Supply System

    Directory of Open Access Journals (Sweden)

    Kuo-Wei Lin

    2012-01-01

    Full Text Available Problem statement: Taiwan is located in the tropical ocean areas. The strong typhoon in summer often causes the collapse of electric transmission towers and results in power outages that seriously affect peoples lives and industrial production. Approach: In light of this situation, this study aims to employ project management techniques of Theory of Constraints (TOC to develop a practical TOC model to quickly repair the towers and restore power supplied system. Results: The actual application had verified that the research model could not only shorten the duration of work but also save the manpower and material expenses. Conclusion: It once again proved the excellent results of reparation operations by applying TOC to project management.

  10. High performance magnet power supply optimization

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, L.T.

    1988-01-01

    The power supply system for the joint LBL--SLAC proposed accelerator PEP provides the opportunity to take a fresh look at the current techniques employed for controlling large amounts of dc power and the possibility of using a new one. A basic requirement of +- 100 ppM regulation is placed on the guide field of the bending magnets and quadrupoles placed around the 2200 meter circumference of the accelerator. The optimization questions to be answered by this paper are threefold: Can a firing circuit be designed to reduce the combined effects of the harmonics and line voltage combined effects of the harmonics and line voltage unbalance to less than 100 ppM in the magnet field. Given the ambiguity of the previous statement, is the addition of a transistor bank to a nominal SCR controlled system the way to go or should one opt for an SCR chopper system running at 1 KHz where multiple supplies are fed from one large dc bus and the cost--performance evaluation of the three possible systems.

  11. High precision power supplies for the National Synchrotron Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, R.; Langenbach, H.

    1987-04-01

    Since beam stability depends to a considerable degree on the stability of the magnet power supplies, and it is desired to push for 3 GeV operation, it was required that new power supplies be obtained for the quadrupoles and sextupoles. These power supplies were to have the lowest ripple that could be reasonably achieved, and were to have a current regulation of better than 10 PPM. In addition, since they operate over a 5 : 1 voltage range, it was considered desirable to ensure that they operated with a good power factor over the operating range. The dipole power supply was modified to use the techniques employed in the smaller supplies.

  12. Effective soil hydraulic conductivity predicted with the maximum power principle

    Science.gov (United States)

    Westhoff, Martijn; Erpicum, Sébastien; Archambeau, Pierre; Pirotton, Michel; Zehe, Erwin; Dewals, Benjamin

    2016-04-01

    Drainage of water in soils happens for a large extent through preferential flowpaths, but these subsurface flowpaths are extremely difficult to observe or parameterize in hydrological models. To potentially overcome this problem, thermodynamic optimality principles have been suggested to predict effective parametrization of these (sub-grid) structures, such as the maximum entropy production principle or the equivalent maximum power principle. These principles have been successfully applied to predict heat transfer from the Equator to the Poles, or turbulent heat fluxes between the surface and the atmosphere. In these examples, the effective flux adapts itself to its boundary condition by adapting its effective conductance through the creation of e.g. convection cells. However, flow through porous media, such as soils, can only quickly adapt its effective flow conductance by creation of preferential flowpaths, but it is unknown if this is guided by the aim to create maximum power. Here we show experimentally that this is indeed the case: In the lab, we created a hydrological analogue to the atmospheric model dealing with heat transport between Equator and poles. The experimental setup consists of two freely draining reservoirs connected with each other by a confined aquifer. By adding water to only one reservoir, a potential difference will build up until a steady state is reached. From the steady state potential difference and the observed flow through the aquifer, and effective hydraulic conductance can be determined. This observed conductance does correspond to the one maximizing power of the flux through the confined aquifer. Although this experiment is done in an idealized setting, it opens doors for better parameterizing hydrological models. Furthermore, it shows that hydraulic properties of soils are not static, but they change with changing boundary conditions. A potential limitation to the principle is that it only applies to steady state conditions

  13. Dynamic Modeling of Hydraulic Power Steering System with Variable Ratio Rack and Pinion Gear

    Science.gov (United States)

    Zhang, Nong; Wang, Miao

    A comprehensive mathematical model of a typical hydraulic power steering system equipped with variable ratio rack and pinion gear is developed. The steering system’s dynamic characteristics are investigated and its forced vibrations are compared with those obtained from a counterpart system with a constant ratio rack and pinion gear. The modeling details of the mechanism subsystem, hydraulic supply lines subsystem and the rotary spool valve subsystem are provided and included in the integrated steering system model. The numerical simulations are conducted to investigate the dynamics of the nonlinear parametric steering system. From the comparison between simulated results and the experimental ones, it is shown that the model accurately integrates the boost characteristics of the rotary spool valve which is the key component of hydraulic power steering system. The variable ratio rack-pinion gear behaviors significantly differently from its constant ratio counterpart does. It significantly affects not only the system natural frequencies but also reduces vibrations under constant rate and ramp torque steering inputs. The developed steering model produces valid predictions of the system’s behavior and therfore could assist engineers in the design and analysis of integrated steering systems.

  14. A Study on the Air Vent Valve of the Hydraulic Servo Actuator for Steam Control of Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Bum; Lee, Jong Jik [Korea Institute of Machinery and Materials, Daejeon (Korea, Republic of)

    2016-06-15

    To produce adequate electricity in nuclear and thermal power plants, an optimal amount of steam should be supplied to a generator connected to high- and low-pressure steam turbines. A turbine output control device, which is a special steam valve employed to supply or interrupt the steam to the turbine, is operated using a hydraulic servo actuator. In power plants, the performance of servo actuators is degraded by the air generated from the hydraulic system, or causes frequent failures owing to an increase in the wear of the seal. This is due to the seal being burnt as generated heat using the produced compressed air. Some power plants have exhausted air using a fixed orifice, and thus they encounter power loss due to mass flow exhaust. Failures are generated in hydraulic pumps, electric motors, and valves, which are frequently operated. In this study, we perform modeling and analysis of the load-sensing air-exhaust valves, which can be passed through very fine flow under normal use conditions, and exhaust mass flow air at the beginning stage as with existing fixed orifices. Then, we propose a method to prevent failures due to the compressed air, and to ensure the control accuracy of hydraulic servo actuators.

  15. Neutron generator power supply modeling in EMMA

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, A.C.; Farnsworth, A.V.; Montgomery, S.T.; Peery, J.S; Merewether, K.O.

    1996-12-01

    Sandia National Laboratories has prime responsibility for neutron generator design and manufacturing, and is committed to developing predictive tools for modeling neutron generator performance. An important aspect of understanding component performance is explosively driven ferroelectric power supply modeling. EMMA (ElectroMechanical Modeling in ALEGRA) is a three dimensional compile time version of Sandia`s ALEGRA code. The code is built on top of the general ALEGRA framework for parallel shock-physics computations but also includes additional capability for modeling the electric potential field in dielectrics. The overall package includes shock propagation due to explosive detonation, depoling of ferroelectric ceramics, electric field calculation and coupling with a general lumped element circuit equation system. The AZTEC parallel iterative solver is used to solve for the electric potential. The DASPK differential algebraic equation package is used to solve the circuit equation system. Sample calculations are described.

  16. 46 CFR 113.43-5 - Power supply.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Power supply. 113.43-5 Section 113.43-5 Shipping COAST... SYSTEMS AND EQUIPMENT Steering Failure Alarm Systems § 113.43-5 Power supply. Each steering failure alarm system must be supplied by a circuit that: (a) Is independent of other steering gear system and...

  17. Power supply system for KSTAR neutral beam injector

    Energy Technology Data Exchange (ETDEWEB)

    Cho, W., E-mail: franciscocho@nfri.re.kr; Bae, Y.S.; Han, W.S.; Jeong, J.H.; Kim, J.S.; Park, H.T.; Yang, H.L.; Oh, Y.K.; Kwak, J.G.

    2015-10-15

    Highlights: • The power supply system in KSTAR NBI consists of DC power supplies for ion source. • For operation NBI, DC High Voltage based on the low voltage transformer with chopper. • The surge absorber near the ion source limit the energy deposited to accelerator grid. - Abstract: The power supply system in KSTAR neutral beam injector consists of low voltage and high current DC power supplies for plasma generator of ion source and high voltage and high current DC power supply for accelerator grid system. The arc discharge is initiated by an arc power supply supplying the arc voltage between the chamber wall and 12 filaments which are heated by individual filament power supply. The negative output of arc power supply is common to each positive output of 12 filament power supplies. To interrupt the arc discharging for the fault condition of the arc current unbalance, DCCT current monitor is placed at the positive output cable of the filament power supply. The plasma grid (G1) power supply has the maximum capability of 120 kV/70 A which consists of low voltage regulator with IGBT-switched chopper array system for the voltage control in unit of 600 V and the high voltage rectified transformers to supply DC voltage of 20 kV, 30 kV, and 50 kV. The output voltage of the G1 power supply is also connected to the input of the voltage divider system which supplies the gradient voltage to the gradient grid (G2) in the range of 80–90% of G1 voltage by changing tap of winding resistors in unit of 1%. The charged G1 voltage is turned on and off by the high voltage switch (HVS) system consisting of MOSFET fast semiconductor switches which can immediately be opened less than 1 μs when the ion source grid breakdown occurs. The decelerating grid (G3) power supply is inverter system using capacitor-charge power supply to supply maximum −5 kV/5 A. The important component in power supply system is the surge absorber near the ion source to limit the arc energy deposited to

  18. Discrete Displacement Hydraulic Power Take-Off System for the Wavestar Wave Energy Converter

    Directory of Open Access Journals (Sweden)

    Enrique Vidal

    2013-08-01

    Full Text Available The Wavestar Wave Energy Converter (WEC is a multiple absorber concept, consisting of 20 hemisphere shaped floats attached to a single platform. The heart of the Wavestar WEC is the Power Take-Off (PTO system, converting the wave induced motion of the floats into a steady power output to the grid. In the present work, a PTO based on a novel discrete displacement fluid power technology is explored for the Wavestar WEC. Absorption of power from the floats is performed by hydraulic cylinders, supplying power to a common fixed pressure system with accumulators for energy smoothing. The stored pressure energy is converted into electricity at a steady pace by hydraulic motors and generators. The storage, thereby, decouples the complicated process of wave power absorption from power generation. The core for enabling this PTO technology is implementing a near loss-free force control of the energy absorbing cylinders. This is achieved by using special multi-chambered cylinders, where the different chambers may be connected to the available system pressures using fast on/off valves. Resultantly, a Discrete Displacement Cylinder (DDC is created, allowing near loss free discrete force control. This paper presents a complete PTO system for a 20 float Wavestar based on the DDC. The WEC and PTO is rigorously modeled from incident waves to the electric output to the grid. The resulting model of +600 states is simulated in different irregular seas, showing that power conversion efficiencies above 70% from input power to electrical power is achievable for all relevant sea conditions.

  19. Dynamic characteristics of hydraulic power steering system with accumulator in load-haul-dump vehicle

    Institute of Scientific and Technical Information of China (English)

    杨忠炯; 何清华; 柳波

    2004-01-01

    Using hydraulic power steering system of model EIMCO 922 load-haul-dump vehicle as a simulation example, the dynamic characteristics of hydraulic power steering system in load-haul-dump vehicle were simulated and discussed with SIMULINK software and hydraulic control theory. The results show that the dynamic characteristics of hydraulic power steering system are improved obviously by using bladder accumulator, the hydraulic power steering system of model EIMCO 922 load-haul-dump vehicle generates vibration at the initial stage under the normal steering condition of pulse input, and its static response time is 0.25 s shorter than that without bladder accumulator. Under the normal steering working condition, the capacity of steering accumulator for absorbing pulse is directly proportional to the cross section area of connecting pipeline, and inversely proportional to the length of connecting pipeline. At the same time, the precharge pressure of nitrogen in steering accumulator should be 60%- 80% of the rated minimum working pressure of hydraulic power steering system. Under the abnormal steering working condition, the steering cylinder piston may obtain higher motion velocity, and the dynamic response velocity of hydraulic power steering system can be increased by reducing the pressure drop of hydraulic pipelines between the accumulator and steering cylinder and by increasing the rated pressure of hydraulic power steering system, but the dynamic characteristics of hydraulic power steering system in load-haul-dump vehicle have nothing to do with the precharge pressure of nitrogen in steering accumulator.

  20. Digitally Controlled High Availability Power Supply

    Energy Technology Data Exchange (ETDEWEB)

    MacNair, David; /SLAC

    2009-05-07

    This paper will report on the test results of a prototype 1320 watt power module for a high availability power supply. The module will allow parallel operation for N+1 redundancy with hot swap capability. The two quadrant output of each module allows pairs of modules to provide a 4 quadrant (bipolar) operation. Each module employs a novel 4 FET buck regulator arranged in a bridge configuration. Each side of the bridge alternately conducts through a small saturable ferrite that limits the reverse current in the FET body diode during turn off. This allows hard switching of the FETs with low switching losses. The module is designed with over-rated components to provide high reliability and better then 97% efficiency at full load. The modules use a Microchip DSP for control, monitoring, and fault detection. The switching FETS are driven by PWM modules in the DSP at 60 KHz. A Dual CAN bus interface provides for low cost redundant control paths. The DSP will also provide current sharing between modules, synchronized switching, and soft start up for hot swapping. The input and output of each module have low resistance FETs to allow hot swapping and isolation of faulted units.

  1. Power supply devices and systems of relay protection

    CERN Document Server

    Gurevich, Vladimir

    2013-01-01

    Power Supply Devices and Systems of Relay Protection brings relay protection and electrical power engineers a single, concentrated source of information on auxiliary power supply systems and devices. The book also tackles specific problems and solutions of relay protection power supply systems and devices, which are often not dealt with in the literature. The author, an experienced engineer with more than 100 patents, draws on his own experience to offer practical, tested advice to readers. A Guide to Relay Protection Power Supply for Engineers and Technicians The first chapter reviews the ele

  2. Electric Power Supply Chain Management Addressing Climate Change

    DEFF Research Database (Denmark)

    Wang, Xiao-Hui; Cong, Ronggang

    2012-01-01

    change. The study compared the difference between electric power supply chain management and traditional supply chain management. Furthermore, some possible research topics are addressed. The aim of this paper was to promote the application of supply chain management in the China electricity sector......Supply chain management played a critical role in the electric power industrial chain optimization. The purpose of this paper was to review a sample of the literature relating to supply chain management and its possible applications in electricity power system, especially in the context of climate...... optimizations and brought a change in the related government policy options....

  3. 46 CFR 113.25-6 - Power supply.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Power supply. 113.25-6 Section 113.25-6 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT General Emergency Alarm Systems § 113.25-6 Power supply. The emergency power...

  4. One of the power supplies used for electrostatic separators

    CERN Multimedia

    1975-01-01

    Internal part of a power supply SAME (± 600 kV, 4 mA). These power supplies were used to power the electrodes (positive and negative), 1 to 9 m length, within a conditioned tank with Ne (30%)/He (70%) at less than a thousandth of mbar. Here, Michel Zahnd, Jean Chaminaud

  5. Improvement of Main Magnetic Field Power Supply of SFC

    Institute of Scientific and Technical Information of China (English)

    ZhangXianlai; YanHuaihai; XinJunye; ZhangShu

    2003-01-01

    The main magnetic field power supply is used for establishing main magnetic field of SFC, therefore excellent current stability and low ripple are required. Its DC output current range is 0~1300 A and max output voltage is 230 V. The power supply has been put into operation since Sep. in 2000, and was replaced in 033 room from 166 room of No.2 Building. We have improved the performance of power supply in this period.

  6. Electrical part Temelin NPP - important electrical appliance power supply

    OpenAIRE

    Trnka, Radek

    2009-01-01

    Radek Trnka Department of Physics, Faculty of Education, University of South Bohemia Electrical part of Temelin Nuclear Power Station - Power supply of important electrical appliances The subject of this bachelor's work is an elaboration of problems of secured electric power supply for all important appliances in Temelin Nuclear Power Station (JE Temelin). There is an essential electrical conception of the nuclear power station described there, as well as possibilities of failure state emerge...

  7. Temperature Stabilized Characterization of High Voltage Power Supplies

    CERN Document Server

    Krarup, Ole

    2017-01-01

    High precision measurements of the masses of nuclear ions in the ISOLTRAP experiment relies on an MR-ToF. A major source of noise and drift is the instability of the high voltage power supplies employed. Electrical noise and temperature changes can broaden peaks in time-of-flight spectra and shift the position of peaks between runs. In this report we investigate how the noise and drift of high-voltage power supplies can be characterized. Results indicate that analog power supplies generally have better relative stability than digitally controlled ones, and that the high temperature coefficients of all power supplies merit efforts to stabilize them.

  8. Fault tolerant system design for uninterruptible power supplies

    Directory of Open Access Journals (Sweden)

    B. Y. Volochiy

    2012-02-01

    Full Text Available The problem of design for reliability of a fault tolerant system for uninterruptible power supplies is considered. Configuration of a fault tolerant system determines the structure of an uninterruptible power supply: power supply built from modules of the same type, stand-by sliding reserve for them, twice total reserve of the power supply with two accumulator batteries, the controls and diagnostics means. The developed tool for automated analytical model of fault tolerant systems generation and illustration of its capabilities in determination of requirements for repair service and accumulator batteries are given.

  9. Power supply system design and build for Antarctica telescope

    Science.gov (United States)

    Du, Fujia; Li, Hao; Li, Aiai

    2016-07-01

    Currently, more and more telescopes were built and installed in Dome A of Antarctic. The telescopes are remote controlled, unattended operation due to Dome A's environment. These telescopes must be work successfully at least one year without any failure. According to past experience, the power supply system is the weakest point in whole system. The telescopes have to stop if the power system have a problem, even a minor problem. So the high requirement for power supply system are presented. The requirement include high reliability, the self-diagnosis and perfect monitor system. Furthermore, the optic telescope only can work at night. The power source mainly relay on diesel engine. To protect the Antarctic environment and increase the life of engines. The power capacity is limited during observation. So it need the power supply system must be high power factor, high efficient. To meet these requirement, one power supply system was design and built for Antarctic telescope. The power supply system have the following features. First, we give priority to achieve high reliability. The reliability of power system was calculated and the redundant system is designed to make sure that the spare one can be work immediately when some parts have problems. Second, the perfect monitor system was designed to monitor the voltage, current, power and power factor for each power channel. The status of power supply system can be acquired by internet continuously. All the status will be logged in main computer for future analysis. Third, the PFC (Power Factor Correction) technology was used in power supply system. This technology can dramatically increase the power factor, especially in high power situation. The DC-DC inverter instead of AC-DC inverter was used for different voltage level to increase the efficient of power supply.

  10. Magnetically switched power supply system for lasers

    Science.gov (United States)

    Pacala, Thomas J. (Inventor)

    1987-01-01

    A laser power supply system is described in which separate pulses are utilized to avalanche ionize the gas within the laser and then produce a sustained discharge to cause the gas to emit light energy. A pulsed voltage source is used to charge a storage device such as a distributed capacitance. A transmission line or other suitable electrical conductor connects the storage device to the laser. A saturable inductor switch is coupled in the transmission line for containing the energy within the storage device until the voltage level across the storage device reaches a predetermined level, which level is less than that required to avalanche ionize the gas. An avalanche ionization pulse generating circuit is coupled to the laser for generating a high voltage pulse of sufficient amplitude to avalanche ionize the laser gas. Once the laser gas is avalanche ionized, the energy within the storage device is discharged through the saturable inductor switch into the laser to provide the sustained discharge. The avalanche ionization generating circuit may include a separate voltage source which is connected across the laser or may be in the form of a voltage multiplier circuit connected between the storage device and the laser.

  11. Employment within the power supply industry and the power supply related activities 2010; Sysselsatte i kraftnaeringen og kraftrelatert virksomhet 2010

    Energy Technology Data Exchange (ETDEWEB)

    Thoen, Haavard

    2011-07-01

    The report's main objective is to investigate employment within the power supply industry and the power supply related activities. The report will describe the composition of employees in regard to sex, age and education. The power supply industry is defined in Statistics Norway's Standard Industrial Classification, as 'Production and distribution of electricity'. The group of companies related to power supply related activities employ similar persons in regard to education and occupation, typical to companies in the power supply industry. In the report, these two groups make up the power supply sector. In 2010 there were 18215 employees in the power supply sector. This constitutes an increase of nearly 12 per cent since 2004 and 1,7 per cent since 2008. The sex distribution of about 80 per cent men and 20 per cent women has been fairly stable since 2004. Compared to the private sector in general the power supply sector has a low share of women among its employees. In 2009 the level of education in the power supply sector was higher than for the private sector in general. Since 2004, the share of persons with higher education has increased from 27 to 33 per cent. Employees in the power supply sector are on an average older than the employees in the private sector. The employees have matured since 2004, but in the last few years, there have also been signs of fresh recruitment. The power supply industry had a net influx of 347 new employees, or 2 percent, in the period between 2009 and 2010. There were 1522 new employees and 1175 employees lost in the sector due to attrition, which gives a turnover rate of 20 percent. If we look at the supply of new employees who were also employed in 2009, 19 percent of female employees worked in temporary staff recruitment agencies. This indicates that temporary work was an entry gate to the power supply industry for many women. Among men, the building- and construction sector was the most common background for

  12. The Power of Supply Chain Finance

    NARCIS (Netherlands)

    Michiel Steeman

    2014-01-01

    Supply chain finance krijgt steeds meer aandacht bij bedrijven als een middel om hun supply chain strategie te ondersteunen. Het gaat hierbij niet alleen om het reduceren van kosten maar ook om het mitigeren van de risico’s in de keten. Wij verwachten dan ook dat vooral bij grote bedrijven de

  13. Quality assurance for CMS Tracker LV and HV Power Supplies

    CERN Document Server

    Costa, Marco; Sertoli, M; Trapani, P; Periale, L; Isabella, L; Landi, C; Lucchesi, A

    2007-01-01

    This work describes the quality assurance measurements that have been carried out on about 2000 Power Supply Units produced in CAEN technology for the CMS Silicon Tracker Detector. The automate procedure and the characteristics of the dedicated Test Fixture developed for this activity are described in details. Magnetic field tolerance and radiation hardness of Tracker power supply units is also discussed at length.

  14. Requirements Specication for Ampliers and Power Supplies in Active Loudspeakers

    DEFF Research Database (Denmark)

    Schneider, Henrik; Jensen, Lasse Crone; Petersen, Lars Press

    2014-01-01

    This work aims to provide designers with a method to develop a requirements specication for power supplies and ampliers in active loudspeakers. The motivation is to avoid over-sizing and unnecessary cost. A realistic estimation of the power supplied during playback of audio in a given loudspeaker...

  15. Intense neutron source: high-voltage power supply specifications

    Energy Technology Data Exchange (ETDEWEB)

    Riedel, A.A.

    1980-08-01

    This report explains the need for and sets forth the electrical, mechanical and safety specifications for a high-voltage power supply to be used with the intense neutron source. It contains sufficient information for a supplier to bid on such a power supply.

  16. Control Electronics for Solar/Flywheel Power Supply

    Science.gov (United States)

    Nola, F. J.

    1986-01-01

    Control circuit automatically directs flow of electrical energy to and from motor with flywheel that constitutes storage element of solar-power system. When insolation is sufficient for charging, power is supplied by solar-cell array to load and motor. During periods of darkness, motor made to act as generator, drawing kinetic energy from flywheel and supplying it to load.

  17. Modular high voltage power supply for chemical analysis

    Science.gov (United States)

    Stamps, James F.; Yee, Daniel D.

    2008-07-15

    A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

  18. Design of a 500 MJ, 5 MA power supply

    Science.gov (United States)

    Pappas, J. A.; Headifen, G. R.; Weldon, J. M.; Wright, J. C.; Zowarka, R. C.; Aanstoos, T. A.; Kajs, J. H.

    1993-01-01

    The design of a 500 MJ, 5 MA power supply for rail gun experiments under the Battery Upgraded Supply (BUS) program is examined. About 50,000 12-volt lead acid batteries are required to reach this level. BUS will be required to perform up to two discharges per week. Therefore, BUS is designed to be a low-maintenance, reliable, and fault-tolerant power supply. The design of BUS and the details of its subsystems are described.

  19. Measurement of H!gh Power Current-Stabilized Power Supply with High Stability

    Institute of Scientific and Technical Information of China (English)

    YanHuaihai; FengXiuming; BaiZhen; ZhouZhongzu

    2003-01-01

    The DC power supply system of HIRFL has been upgraded since 1999, these new power supplies are used mainly as high frequency ZVS soft-switching converters or thyristor phase-controlled rectifiers. Each power supply is strictly tested before being put into operation, especially for long-term current stability, current ripple, efficiency, repeatability, EMI and so on. The tested results indicated that performances of power supplies satisfy requirement of HIRFL.

  20. Solid state modulator for klystron power supply XFEL TDS INJ

    Science.gov (United States)

    Zavadtsev, A. A.; Zavadtsev, D. A.; Zybin, D. A.; Churanov, D. V.; Shemarykin, P. V.

    2016-09-01

    The transverse deflecting system XFEL TDS INJ for European X-ray Free Electron Laser includes power supply for the CPI VKS-8262HS klystron. It has been designed for pulse high-voltage, cathode heating, solenoid and klystron ion pump. The klystron power supply includes solid state modulator, pulse transformer, controlled power supply for cathode heating and commercial power supplies for solenoid and ion pump. Main parameters of the modulator are 110 kV of peak voltage, 72 A peak current, and pulse length up to 6 μs. The klystron power supply has been developed, designed, manufactured, tuned, tested and installed in the XFEL building. All designed parameters are satisfied.

  1. Employment within the power supply industry and the power supply related activities; Sysselsatte i kraftnaeringen og kraftrelatert virksomhet 2011

    Energy Technology Data Exchange (ETDEWEB)

    Thoen, Haavard

    2012-07-01

    The report's main objective is to investigate employment within the power supply industry and the power supply related activities. The report will describe the composition of employees in regard to sex, age and education. The power supply industry is defined in Statistics Norway's Standard Industrial Classification, as 'Production and distribution of electricity'. The group of companies related to power supply related activities employ similar persons in regard to education and occupation, typical to companies in the power supply industry. These two groups make up the power supply sector in this report. In 2011 there were 18 450 employees in the power supply sector. This constitutes an increase of nearly 13.5 per cent since 2004 and 1.1 per cent since 2010. The sex distribution of about 80 per cent men and 20 per cent women has been fairly stable since 2004. The power supply sector has a low share of women among its employees compared to the private sector in general. In 2011 the level of education in the power supply sector was higher than for the private sector in general. Since 2004, the share of persons with higher education has increased from 27 to 33 per cent. Employees in the power supply sector are on average older than employees in the private sector. The employees have matured since 2004, but in the last few years, there have also been signs of fresh recruitment. The power supply industry had a net influx of 380 new employees, in the period between 2009 and 2011. There were 1678 new employees and 1298 employees lost in the sector due to attrition. If we look at the supply of new employees who were also employed in 2010, 14.2 percent of female employees worked in temporary staff recruitment agencies. Temporary work seems to be an important entry gate to the power supply industry for women. Among men, the building- and construction sector was the most common background for new employees in the power supply industry. Among people who quit

  2. Planning Mechanisms for Regional Electric Power Supply System Development

    Directory of Open Access Journals (Sweden)

    Evgeniy Anatolyevich Malyshev

    2015-12-01

    Full Text Available Key problems of the regional electric power supply systems are examined. These problems result from a lack of regulated interaction mechanisms for uniting the different entities’ resources aimed at the realization of investment activities. One of the main problems of the power supply industry is physical and moral aging of both generating and networking equipment. In the article, the necessity of management system formation to control the development of power sector has been proved. The deficiencies of the modern investment procedure in power companies are described. The absence of continuity between the regional and local strategic planning documents and investment planning of a power company has been found out. The possibility to develop a new mechanism for attracting investment has been proposed. The regulation of joint activities to implement the development program for the regional power supply industry has been proposed. The management system to develop the Russian power industry has been proposed. The comparative analysis of generating capacity development mechanisms has been carried out, such as capacity supply agreement (CSA, investment support mechanism (ISM, and long-term power market (LPM. The interaction procedure of the planning of the power supply infrastructure development has been described. The mechanism connecting the state sectoral and regional planning and corporate planning of power supply infrastructure development has been proposed. The regional aspects of industrial policy and its legislative support have been considered. To successfully implement the public-private-partnership (PPP projects, it is necessary to create the effective PPP model within the federal and regional legislation framework; to develop the financial model providing the recoverability of investments; to provide a mutually beneficial cooperation between executive bodies and private investors. The possibility to apply the PPP mechanism for regional

  3. The Effect of Flywheel Unbalance on Gear Noise in the Hydraulic Power Plant Turbo-Generator

    Directory of Open Access Journals (Sweden)

    Tomeh Elias

    2017-01-01

    Full Text Available The Effect of Flywheel Unbalance on Gear Noise in the Hydraulic Power Plant Turbo-Generator. Hydraulic power plants are systems that produce electrical energy with high investment costs. In order to fulfil their goals, investments should create conditions for a safe production of energy in a long lasting and reliable way, and with the required power and quality. These goals are possible to reach by an optional control process linked to a systematic monitoring of the operating machinery state, using the method of vibration diagnostics. Lately, there has been an increase of noise level in the hydraulic power plants.

  4. PRESSURE COMPENSATION METHOD OF UNDERWATER HYDRAULIC SYSTEM WITH HYDRAULIC POWER UNIT BEING UNDER ATMOSPHERIC CIRCUMSTANCE AND PRESSURE COMPENSATED VALVE

    Institute of Scientific and Technical Information of China (English)

    Wang Qingfeng; Li Yanmin; Zhong Tianyu; Xu Guohua

    2005-01-01

    Based on the analysis of the-state-of-the-art of pressure compensation of underwater hydraulic systems (UHSs), a new method of pressure compensation of UHSs, whose hydraulic power unit is in the atmospheric circumstance, is proposed. And a pilot-operated relief valve with pressure compensation is realized. The pressure compensation precision is guaranteed by direct detection. Its dynamic performance and stability are improved by a dynamic feedback. Theoretical study, simulation and experiment show that the pilot-operated relief valve with pressure compensation has a fine property of tracking underwater ambient pressure and meet the requirement of underwater ambient pressure compensation.

  5. Intelligent Vehicle Electrical Power Supply System with Central Coordinated Protection

    Institute of Scientific and Technical Information of China (English)

    YANG Diange; KONG Weiwei; LI Bing; LIAN Xiaomin

    2016-01-01

    The current research of vehicle electrical power supply system mainly focuses on electric vehicles (EV) and hybrid electric vehicles (HEV). The vehicle electrical power supply system used in traditional fuel vehicles is rather simple and imperfect;electrical/electronic devices (EEDs) applied in vehicles are usually directly connected with the vehicle’s battery. With increasing numbers of EEDs being applied in traditional fuel vehicles, vehicle electrical power supply systems should be optimized and improved so that they can work more safely and more effectively. In this paper, a new vehicle electrical power supply system for traditional fuel vehicles, which accounts for all electrical/electronic devices and complex work conditions, is proposed based on a smart electrical/electronic device (SEED) system. Working as an independent intelligent electrical power supply network, the proposed system is isolated from the electrical control module and communication network, and access to the vehicle system is made through a bus interface. This results in a clean controller power supply with no electromagnetic interference. A new practical battery state of charge (SoC) estimation method is also proposed to achieve more accurate SoC estimation for lead-acid batteries in traditional fuel vehicles so that the intelligent power system can monitor the status of the battery for an over-current state in each power channel. Optimized protection methods are also used to ensure power supply safety. Experiments and tests on a traditional fuel vehicle are performed, and the results reveal that the battery SoC is calculated quickly and sufficiently accurately for battery over-discharge protection. Over-current protection is achieved, and the entire vehicle’s power utilization is optimized. For traditional fuel vehicles, the proposed vehicle electrical power supply system is comprehensive and has a unified system architecture, enhancing system reliability and security.

  6. Intelligent vehicle electrical power supply system with central coordinated protection

    Science.gov (United States)

    Yang, Diange; Kong, Weiwei; Li, Bing; Lian, Xiaomin

    2016-07-01

    The current research of vehicle electrical power supply system mainly focuses on electric vehicles (EV) and hybrid electric vehicles (HEV). The vehicle electrical power supply system used in traditional fuel vehicles is rather simple and imperfect; electrical/electronic devices (EEDs) applied in vehicles are usually directly connected with the vehicle's battery. With increasing numbers of EEDs being applied in traditional fuel vehicles, vehicle electrical power supply systems should be optimized and improved so that they can work more safely and more effectively. In this paper, a new vehicle electrical power supply system for traditional fuel vehicles, which accounts for all electrical/electronic devices and complex work conditions, is proposed based on a smart electrical/electronic device (SEED) system. Working as an independent intelligent electrical power supply network, the proposed system is isolated from the electrical control module and communication network, and access to the vehicle system is made through a bus interface. This results in a clean controller power supply with no electromagnetic interference. A new practical battery state of charge (SoC) estimation method is also proposed to achieve more accurate SoC estimation for lead-acid batteries in traditional fuel vehicles so that the intelligent power system can monitor the status of the battery for an over-current state in each power channel. Optimized protection methods are also used to ensure power supply safety. Experiments and tests on a traditional fuel vehicle are performed, and the results reveal that the battery SoC is calculated quickly and sufficiently accurately for battery over-discharge protection. Over-current protection is achieved, and the entire vehicle's power utilization is optimized. For traditional fuel vehicles, the proposed vehicle electrical power supply system is comprehensive and has a unified system architecture, enhancing system reliability and security.

  7. Analysis of power supply circuits for electroluminescent panels

    Science.gov (United States)

    Drumea, Andrei; Dobre, Robert Alexandru

    2016-12-01

    The electroluminescent panel is a light emitting device that requires for normal operations alternative voltages with peak to peak amplitudes in 100V… 300V range and frequencies in 100Hz … 2 kHz range. Its advantages, when compared with standard light sources like incandescent lamps, gas-discharge lamps or light emitting diodes (LEDs), are lower power consumption, flexible substrate and uniform light without observable luminous points. One disadvantage of electroluminescent panels is the complex power supply required to drive them, but the continuous improvement in passive and active integrated devices for switched mode power supplies will eventually solve this issue. The present paper studies different topologies for these power supplies and the effect of the electric parameters like the amplitude, frequency, waveform of the supplying voltage on the light emission and on power consumption for electroluminescent panels with different size and colors.

  8. Thermal control of power supplies with electronic packaging techniques

    Science.gov (United States)

    1975-01-01

    The analysis, design, and development work to reduce the weight and size of a standard modular power supply with a 350 watt output was summarized. By integrating low cost commercial heat pipes in the redesign of this power supply, weight was reduced by 30% from that of the previous design. The temperature was also appreciably reduced, increasing the environmental capability of the unit. A demonstration unit with a 100 watt output and a 15 volt regulator module, plus simulated output modules, was built and tested to evaluate the thermal performance of the redesigned power supply.

  9. Injector power supplies reliability improvements at the Advanced Photon Source.

    Energy Technology Data Exchange (ETDEWEB)

    Hillman, A.; Pasky, S.; Sereno, N.; Soliday, R.; Wang, J.

    2006-01-01

    Operational goals for the Advanced Photon Source (APS) facility include 97% availability and a mean time between unscheduled beam losses (faults) of 70 hours, with more than 5000 user hours of scheduled beam per year. To meet this objective, our focus has been maximizing the mean time between faults (MTBF). We have made various hardware and software improvements to better operate and monitor the injector power supply systems. These improvements have been challenging to design and implement in light of the facility operating requirements but are critical to maintaining maximum reliability and availability of beam for user operations. This paper presents actions taken as well as future plans to continue improving injector power supply hardware and software to meet APS user operation goals. The Advanced Photon Source (APS) has two major components. The storage ring (SR) accelerator is the primary accelerator that delivers X-ray beams to users and uses over 1,400 power supplies. The injector accelerators provide beam to the SR and use 361 different supplies. The control system ranges from the standard VME-IOC and Allen Bradley to GESPAC with additional mini-PLCs for monitoring. Injector power supplies range from {approx}30 watts DC to a ramped peak of 4.6 megawatts in 250 ms. Finally, all accelerators use pulsed supplies, and some of them deliver peak power in megawatts. In the SR, each multipole and corrector magnet is separately powered, with only the main dipole magnets on a common bus. Independent power supplies provide increased flexibility, but place additional demands on power supply reliability. The APS reliability goals are 97% availability and 70 hours mean time to unscheduled beam loss. There are 5,129 user hours scheduled per year, 1,315 hours used for machine studies, and the remaining 2,316 hours used for maintenance. The present annual operating schedule provides for three user runs (typically 10 to 12 weeks long), and three machine shutdowns (typically

  10. Hydraulic analysis of water supply networks and controlling the leak using WATER GEMS model

    Directory of Open Access Journals (Sweden)

    Mahmood Motevalizadeh

    2016-03-01

    Full Text Available Given that the discussion on water is strategic in terms of economic and social aspects as well as environmental impact, water leak in urban water-supply systems is very important, so, dealing with it is necessary and inevitable. Controlling and reducing water leak are of the main goals of water supplier organization due to limitations in terms of water resources, especially in dry lands which have few water resources. Pressure management is an efficient tool to reduce costs, enhance the operation of the network and therefore, it reduces the leak and increases the life of facilities and equipment and reduces the number of accidents. Smart pressure containment is a good way to prevent excess pressure in network to control undesirable phenomenon of leak which is directly related to pressure. In this study, Badamuiyeh water supply complex in Kerman City was selected to study on adjusting the pressure to control the leak of water and the hydraulic analysis was performed with demand-based method (DDSM, which is common technique and demand is constant, by Water GEMS software. For this end, the pressure reducing valves (prv were installed in critical point and they were timed to provide standard pressure in all nodes of the network and then, the impact of smart pressure management on water supply system has been investigated. Then its impact on the leak was examined and the results show that smart pressure control through pressure-reducing valve is a proper method for optimal management of water and reducing the leak significantly that with 45.15% reduction in average pressure, one can reduce the leak as much as 25.67% that as its result, 15380 m3 of water is annually saved in this region which is equal to 27.18% of consuming water.

  11. A Feasibility Study of Power Generation from Sewage Using a Hollowed Pico-Hydraulic Turbine

    Directory of Open Access Journals (Sweden)

    Tomomi Uchiyama

    2016-12-01

    Full Text Available This study is concerned with the feasibility of power generation using a pico-hydraulic turbine from sewage flowing in pipes. First, the sewage flow rate at two connection points to the Toyogawa River-Basin Sewerage, Japan, was explored for over a year to elucidate the hydraulic energy potential of the sewage. Second, the performance of the pico-hydraulic turbine was investigated via laboratory experiments that supposed the turbine to be installed in the sewage pipe at the connection points. This study indicates that the connection points have hydraulic potential that can be used for power generation throughout the year. It also demonstrates that the pico-hydraulic turbine can be usefully employed for power generation from sewage flowing in the pipe at the connection points.

  12. Pivotal suppliers and market power in experimental supply function competition

    NARCIS (Netherlands)

    Brandts, J.; Reynolds, S.; Schram, A.

    2011-01-01

    In the process of regulatory reform in the electric power industry, the mitigation of market power is one of the basic problems regulators have to deal with. We use experimental data to study the sources of market power with supply function competition, akin to the competition in wholesale electrici

  13. A Robust Modular IGBT Power Supply for Fusion Science Applications

    Science.gov (United States)

    Ziemba, Timothy; Miller, Ken; Prager, James

    2010-11-01

    A present challenge facing the fusion energy community and particularly the ICC community in its support of the main line tokamak program is the ability to generate increased power levels for pulsed magnets, arc plasma sources, radio frequency heating, and current drive schemes, at reasonable cost. Continuous wave (CW) tube based power supplies are typically large and expensive, making them prohibitive for smaller experimental facilities or not cost effective when only pulsed input power is required. Continued research and development of next generation solid state power supplies could allow for multiple applications with a single well developed, low cost module that could be configured in many ways. Eagle Harbor Technologies has developed, built, and tested a modular solid state power supply based on Insulate Gate Bi-polar Transistor (IGBT) technologies. The power supply utilized a modular, low cost, high power IGBT based system that can be assembled in multiple ways to address a wide range of applications. Testing results demonstrating the prototype abilities in both parallel and series configurations and for both high current and/or high voltage operation will be presented. The prototype cost was shown to be significantly lower than older generation power supplies for similar applications. Future work includes upgrading the prototype for increased power levels (> 10 MW).

  14. Safety of power transformers, power supplies, reactors and similar products - Part 1: General requirements and tests

    CERN Document Server

    International Electrotechnical Commission. Geneva

    1998-01-01

    This International Standard deals with safety aspects of power transformers, power supplies, reactors and similar products such as electrical, thermal and mechanical safety. This standard covers the following types of dry-type transformers, power supplies, including switch mode power supplies, and reactors, the windings of which may be encapsulated or non-encapsulated. It has the status of a group safety publication in accordance with IEC Guide 104.

  15. Solid State Capacitor Discharge Pulsed Power Supply Design for Railguns

    Science.gov (United States)

    2007-03-01

    CAPACITOR DISCHARGE PULSED POWER SUPPLY DESIGN FOR RAILGUNS by Jesse H. Black March 2007 Thesis Advisor: Alexander L. Julian Co-Advisor...switched power supply capable of providing 50 kJ from a high voltage capacitor to a railgun . The efficiency with which energy is transferred from a...also produce a smaller electromagnetic pulse. Voltage limitations on the thyristors require two in series acting as a single switch. Railgun

  16. A Robust Modular IGBT Power Supply for Magnetic Confinement Concepts

    Science.gov (United States)

    Ziemba, Timothy; Miller, Ken; Carscadden, John; Prager, Jim

    2009-11-01

    Among current challenges in fusion science, and in particular within the Innovative Confinement Concepts (ICC) community, is the ability to generate increased power levels for pulsed magnets, arc plasma sources, radio frequency (RF) heating and current drive schemes at reasonable cost with current generation solid state devices. Continuous wave (CW) tube based power supplies are typically large and expensive, making them prohibitive for smaller experimental facilities or not cost effective when only pulsed input power is required. Next generation solid state power supplies could allow for multiple use applications with a single well developed module that can be easily reconfigured. As such, this type of robust power supply could be beneficial to several important fusion applications including high power RF heating and current drive schemes, high current pulsed magnets and plasma pre-ionization sources. Data will be presented on design characteristics and testing of a modular robust solid state power supply based on Insulate Gate Bi-polar Transistor (IGBT) technologies and developed by Eagle Harbor Technologies, INC. The modular power supply system can be assembled in multiple ways to address a wide range of applications and needs for the magnetic confinement community.

  17. Energy efficiency of computer power supply units - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Aebischer, B. [cepe - Centre for Energy Policy and Economics, Swiss Federal Institute of Technology Zuerich, Zuerich (Switzerland); Huser, H. [Encontrol GmbH, Niederrohrdorf (Switzerland)

    2002-11-15

    This final report for the Swiss Federal Office of Energy (SFOE) takes a look at the efficiency of computer power supply units, which decreases rapidly during average computer use. The background and the purpose of the project are examined. The power supplies for personal computers are discussed and the testing arrangement used is described. Efficiency, power-factor and operating points of the units are examined. Potentials for improvement and measures to be taken are discussed. Also, action to be taken by those involved in the design and operation of such power units is proposed. Finally, recommendations for further work are made.

  18. PTC thermistor protects multiloaded power supplies

    Science.gov (United States)

    Leverone, H.; Mandell, N.

    1964-01-01

    A PTC /Positive-Temperature-Coefficient/ thermistor placed in series with each branch load of a multiload circuit prevents power loss in parallel branches. This thermistor may be used in any circuit requiring current limiting or intended overload resetting.

  19. Design and Construction of Low Cost High Voltage dc Power Supply for Constant Power Operation

    Science.gov (United States)

    Kumar, N. S.; Jayasankar, V.

    2013-06-01

    Pulsed load applications like laser based systems need high voltage dc power supplies with better regulation characteristics. This paper presents the design, construction and testing of dc power supply with 1 kV output at 300 W power level. The designed converter has half bridge switched mode power supply (SMPS) configuration with 20 kHz switching. The paper covers the design of half bridge inverter, closed loop control, High frequency transformer and other related electronics. The designed power supply incorporates a low cost OPAMP based feedback controller which is designed using small signal modelling of the converter. The designed converter was constructed and found to work satisfactorily as per the specifications.

  20. Market Design and Supply Security in Imperfect Power Markets

    DEFF Research Database (Denmark)

    Schwenen, Sebastian

    2014-01-01

    Supply security in imperfect power markets is modelled under different market designs. In a uniform price auction for electricity with two firms, strategic behaviour may leave firms offering too few capacities and unable to supply all realized demand. Market design that relies oncapacity markets...... increases available generation capacities for sufficiently high capacity prices and consequently decreases energy prices. However, equilibrium capacity prices are non-competitive. Capacity markets can increase security of supply, but cannot mitigate market power, which is exercised in the capacity market...

  1. Simulation of cavitation in rotary valve of hydraulic power steering gear

    Institute of Scientific and Technical Information of China (English)

    LIU YaHui; JI XueWu

    2009-01-01

    Hydraulic power steering gear supplies assistant power by liquid stream.The stream will be changed greatly for the flow field formed by the rotary valve will vary during steering.And the change of the stream in this narrow field will (be big enough to) cause the fluctuation of the assistance power and noise of the steering gear.3-D meshes of the flow field between the sleeve and the rotor of the valve with different structure parameters such as entry caliber and groove depth were set up and a general CFD code-Fluent was used to analyze the stream performance.The results including pressure and gas-phase's volume fraction were analyzed under certain operation flow rate.It was found that the entry caliber did not affect the operation pressure of the valve under the same flow rate but affected the gas-phase's volume fraction of the flow field, and so did the groove depth of the valve' sleeve and rotor.Many researches have pointed that the noise of steering valve is almost cavitation noise, that is, the gas-phase in the flow field has great correlation with rotary valve noise.Based on these analyses of the stream in the rotary steering valve, this paper gave suggestion that increasing entry caliber of the ro-tary valve and choosing appropriate groove depth will reduce the valve noise.

  2. Simulation of cavitation in rotary valve of hydraulic power steering gear

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Hydraulic power steering gear supplies assistant power by liquid stream. The stream will be changed greatly for the flow field formed by the rotary valve will vary during steering. And the change of the stream in this narrow field will (be big enough to) cause the fluctuation of the assistance power and noise of the steering gear. 3-D meshes of the flow field between the sleeve and the rotor of the valve with different structure parameters such as entry caliber and groove depth were set up and a general CFD code-Fluent was used to analyze the stream performance. The results including pressure and gas-phase’s volume fraction were analyzed under certain operation flow rate. It was found that the entry caliber did not affect the operation pressure of the valve under the same flow rate but affected the gas-phase’s volume fraction of the flow field, and so did the groove depth of the valve’ sleeve and rotor. Many researches have pointed that the noise of steering valve is almost cavitation noise, that is, the gas-phase in the flow field has great correlation with rotary valve noise. Based on these analyses of the stream in the rotary steering valve, this paper gave suggestion that increasing entry caliber of the rotary valve and choosing appropriate groove depth will reduce the valve noise.

  3. POWER SUPPLY UNIT FOR COMMERCIAL GREENHOUSES

    Directory of Open Access Journals (Sweden)

    Sit M.

    2014-12-01

    Full Text Available The aim of the work is to develop the energy efficient schemes for energy supply of the industrial greenhouse designed for year-round production of plants that requires year-round maintenance of strongly prescribed temperature and humidity inside. We have been elaborated the complex "gas driven heat pump “water-air” – electric generator" (for use during the heating season as well as the "gas driven heat pump “water-air” – electric generator – desiccant – evaporative chiller" (for use during the off-season. Proposed structures have a high energetic and economic efficiency as compared with conventional schemes (boiler - chiller. The proposed complex ensures year-round maximum COP of heat pump and maximum performance of gas engine.

  4. Photovoltaic / Diesel / Battery Hybrid Power Supply System

    CSIR Research Space (South Africa)

    Tazvinga, Henerica

    2010-10-01

    Full Text Available electricity being allocated to the more important urban sector. The relatively low energy demand in rural areas does not compensate the cost of long-range transmission lines from the national grid. This justifies the use of more decentralised forms of power...

  5. Integrated Electrical Power Supply System for Propulsion and Service Control.

    Science.gov (United States)

    1996-08-16

    propellers with hydraulically controlled pitch for ship propulsion . In such arrangement of equipment, two gas turbines customarily drive each of two...availability of commercial technology presently utilized on cruise ships having service equipment loads larger than their ship propulsion loads. However...accentuated on naval combat ships wherein a larger proportion of the power is utilized for ship propulsion purposes and operational efficiency is of

  6. Low power DCVSL circuits employing AC power supply

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    In view of changing the type of energy conversion in CMOS circuits, this paper investigates low power CMOS circuit design, which adopts a gradually changing power clock. First, we discuss the algebraic expressions and the corresponding properties of clocked power signals. Then the design procedure is summed up for converting complementary CMOS logic gates employing DC power to the power-clocked CMOS gates employing AC power. On this basis, the design of differential cascode voltage switch logic (DCVSL) circuits employing AC power clocks is proposed. The PSPICE simulations using a sinusoidal power-clock demonstrate that the designed power-clocked DCVSL circuit has a correct logic function and low power characteristics. Finally, an interface circuit to convert clocked signals into the standard logic levels of a CMOS circuit is proposed, and its validity is verified by computer simulations.

  7. Research on Discharge Circuit of Electro-Hydraulic Power Impulse Water Jets

    Science.gov (United States)

    Wang, Zhaohui; Gao, Quanjie; Wang, Wei; Liao, Zhenfang

    2012-01-01

    Electro-hydraulic power impulse water jets can convert the shock wave generated in the liquid by discharging into mechanical energy, and it has been widely used in material forming, surface cleaning, pipeline dirt cleaning and ore breaking process. Compared with the traditional high pressure water jets, the energy utilization of electro-hydraulic power impulse water jets is up to 80% while the water consumption is reduced by 40-55%. This paper has taken electro-hydraulic power impulse water jets as the research object, employed obtaining the maximum pressure of compression impulse matrix surface as the research goal, studied in depth the equivalent discharge circuit, characteristic equation and the relationship between the electrical parameters of the electro-hydraulic power impulse discharge circuit and built the calculation method of the voltage, the inductance, the capacitance and the electrode spacing parameter of electro-hydraulic power impulse water jets discharge circuit. So, it will provide important theoretical basis for further studies of electro-hydraulic power impulse technology and the existing water jets device.

  8. Restructuring power supply in Germany; Umstrukturierung der Stromversorgung in Deutschland

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-05-15

    According to recent calculations of the Umweltbundesamt (Federal Environmental Office), all German nuclear power plants can be decommissioned from 2017. This will result neither in supply shortages nor in higher electricity rates, and Germany's climate protection goals will not be in danger either. There will be no need to import nuclear power from other countries. (orig.)

  9. REDUCED-PARTS THREE-PHASE UNINTERRUPTIBLE POWER SUPPLY

    Directory of Open Access Journals (Sweden)

    RĂZVAN DANIEL ALBU

    2008-05-01

    Full Text Available In this paper, a three-phase on-lineuninterruptible power supply with reducednumber of switches topology is presented. The newtopology has less number of power electronicdevices as well as control functions. Differentoperating modes of the system are investigated aswell. Simulation and experimental results arepresented, which show the viability of the proposedtopology.

  10. Optimizing efficiency on conventional transformer based low power AC/DC standby power supplies

    DEFF Research Database (Denmark)

    Nielsen, Nils

    2004-01-01

    This article describes the research results for simple and cheap methods to reduce the idle- and load-losses in very low power conventional transformer based power supplies intended for standby usage. In this case "very low power" means 50 Hz/230 V-AC to 5 V-DC@1 W. The efficiency is measured...... on two common power supply topologies designed for this power level. The two described topologies uses either a series (or linear) or a buck regulation approach. Common to the test power supplies is they either are using a standard cheap off-the-shelf transformer, or one, which are loss optimized by very...

  11. A novel testing approach for SSRF digital power supply controllers

    Institute of Scientific and Technical Information of China (English)

    KE Xinhua; LU Songlin; LI Rui; XU Ruinian; SHEN Tianjian

    2008-01-01

    Digital power supply controller is one of the key parts of SSRF high resolution high stability magnet power supply system.It is very essential to keep any degradation of these excellent properties by any stages as small as possible via careful testing when the controller is developed.In this study,a novel testing approach was presented,with which a novel closed conrail loop without actual power converter was constructed,and the new developed SSRF Digital Controller can work well in it.

  12. Very High Frequency Switch-Mode Power Supplies

    DEFF Research Database (Denmark)

    Madsen, Mickey Pierre

    The importance of technology and electronics in our daily life is constantly increasing. At the same time portability and energy efficiency are currently some of the hottest topics. This creates a huge need for power converters in a compact form factor and with high efficiency, which can supply...... these electronic devices. This calls for new technologies in order to miniaturize the power electronics of today. One way to do this is by increasing the switching frequency dramatically and develop very high frequency switch mode power supplies. If these converters can be designed to operate efficiently, a huge...... of technologies for very high frequency switch mode power supplies. At these highly elevated frequencies normal bulky magnetics with heavy cores consisting of rare earth materials, can be replaced by air core inductors embedded in the printed circuit board. This is investigated thoroughly and both spirals...

  13. A new high current laboratory and pulsed homopolar generator power supply at the University of Texas

    Science.gov (United States)

    Floyd, J. E.; Aanstoos, T. A.

    1984-03-01

    The University of Texas at Austin is constructing a facility for research in pulse power technology for the Center for Electromechanics at the Balcones Research Center. The facility, designed to support high-current experiments, will be powered by six homopolar generators, each rated at 10 MJ and arranged to allow matching the requirements of resistive and inductive loads at various voltage and current combinations. Topics covered include the high bay, the power supply configuration and parameters, the speed and field control, and the magnetic circuit. Also considered are the removable air-cooled brushes, the water-cooled field coils, the hydraulic motor sizing and direct coupling, the low-impedance removable field coils, and the hydrostatic bearing design.

  14. On the Ongoing Evolution of Very High Frequency Power Supplies

    DEFF Research Database (Denmark)

    Knott, Arnold; Andersen, Toke Meyer; Kamby, Peter

    2013-01-01

    in radio frequency transmission equipment helps to overcome those. However those circuits were not designed to meet the same requirements as power converters. This paper summarizes the contributions in recent years in application of very high frequency (VHF) technologies in power electronics, describes......The ongoing demand for smaller and lighter power supplies is driving the motivation to increase the switching frequencies of power converters. Drastic increases however come along with new challenges, namely the increase of switching losses in all components. The application of power circuits used...

  15. A new linear type hydraulic motor

    Science.gov (United States)

    Jiang, Dong; Zhang, Tong; Li, Wenhua; Chen, Xinyang

    2017-08-01

    This paper proposes the design of liner type hydraulic motor on the base of inner curved radial piston hydraulic motor. The hydraulic cylinders of the new type motor are in the straight line which will improve the utilization of the axial space and different out power can be supplied by changes the number of cylinders. In this paper, the structure and working principle of the liner type hydraulic motor is introduced.

  16. Unique Power Dense, Configurable, Robust, High-Voltage Power Supplies Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Princeton Power will develop and deliver three small, lightweight 50 W high-voltage power supplies that have a configurable output voltage range from 500 to 50 kVDC....

  17. SYNTHESIS OF MODULAR UNINTERRUPTED POWER SUPPLY SYSTEMS WITH INCREASED RELIABILITY

    Directory of Open Access Journals (Sweden)

    Grigorash O. V.

    2015-04-01

    Full Text Available The level of technical development today requires the creation of highly effective, including reliable, uninter-rupted power supply systems. We have shown modern requirements and design features of modern systems of uninterruptible power supply, which should be built on a modular principle. It is shown that the problem of synthesis of systems in a modular approach is addressing three issues: development of the structure of the system subject to the requirements of consumers to quality of power and the allowable time of power outage; determining the required level redundancy of major functional units (blocks, elements to ensure the required reliability of the system; - ensuring the most effective interconnection of modules, including electromagnetic compatibility, and the rational use during normal and emergency operation of the system. We have proposed new structural solution of the main functional units and uninterrupted power supply systems in modular design. To reduce EMI and improve efficiency uninterruptible power supply systems in the design of static converters we need to use a transformer with a rotating magnetic field. In addition, the prospective current is to be used as a source of renewable energy. Another promising approach is the use of direct frequency converters as voltage stabilizers and frequency of the current

  18. Application of flow network models of SINDA/FLUINT{sup TM} to a nuclear power plant system thermal hydraulic code

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Ji Bum [Institute for Advanced Engineering, Yongin (Korea, Republic of); Park, Jong Woon [Korea Electric Power Research Institute, Taejon (Korea, Republic of)

    1998-12-31

    In order to enhance the dynamic and interactive simulation capability of a system thermal hydraulic code for nuclear power plant, applicability of flow network models in SINDA/FLUINT{sup TM} has been tested by modeling feedwater system and coupling to DSNP which is one of a system thermal hydraulic simulation code for a pressurized heavy water reactor. The feedwater system is selected since it is one of the most important balance of plant systems with a potential to greatly affect the behavior of nuclear steam supply system. The flow network model of this feedwater system consists of condenser, condensate pumps, low and high pressure heaters, deaerator, feedwater pumps, and control valves. This complicated flow network is modeled and coupled to DSNP and it is tested for several normal and abnormal transient conditions such turbine load maneuvering, turbine trip, and loss of class IV power. The results show reasonable behavior of the coupled code and also gives a good dynamic and interactive simulation capabilities for the several mild transient conditions. It has been found that coupling system thermal hydraulic code with a flow network code is a proper way of upgrading simulation capability of DSNP to mature nuclear plant analyzer (NPA). 5 refs., 10 figs. (Author)

  19. PEP-II Large Power Supplies Rebuild Program at SLAC

    Energy Technology Data Exchange (ETDEWEB)

    Bellomo, P.; Lipari, J.J.; de Lira, A.C.; Rafael, F.S.; /SLAC

    2005-05-17

    Seven large power supplies (LGPS) with output ratings from 72kW to 270kW power PEP-II quad magnets in the electron-positron collider region. These supplies have posed serious maintenance and reliability problems since they were installed in 1997, resulting in loss of accelerator availability. A redesign/rebuild program was undertaken by the SLAC Power Conversion Department. During the 2004 summer shutdown all the control circuits in these supplies were redesigned and replaced. A new PWM control board, programmable logic controller, and touch panel have been installed to improve LGPS reliability, and to make troubleshooting easier. In this paper we present the details of this rebuilding program and results.

  20. Advanteges of using Two-Switch Forward in Single-Stage Power Factor Corrected Power Supplies

    DEFF Research Database (Denmark)

    Petersen, Lars

    2000-01-01

    A single-Stage power factor corrected power supply using a two-switch forward is proposed to increase efficiency. The converter is operated in the DCM (Discontinues Conduction Mode). This will insure the intermediate DC-bus to be controlled only by means of circuit parameters and therefore...... power supply has been implemented. The measured efficiency and power factor are about 87% and 0.96 respectively....

  1. A high-power switch-mode dc power supply for dynamic loads

    Energy Technology Data Exchange (ETDEWEB)

    Shimer, D.W.; Lange, A.C. [Lawrence Livermore National Lab., CA (United States); Bombay, J.N. [Kaiser Engineers, Oakland, CA (United States)

    1994-06-23

    High-voltage dc power supplies are often required to operate with highly dynamic loads, such as arcs. A switch-mode dc power supply can offer significant advantages over conventional thyristor-based dc power supplies under such conditions. It can quickly turn off the supply to extinguish the arc, and it can quickly recover after the arc. It has a relatively small output filter capacitance, which results in small stored energy available to the arc. A 400-kW, 50-kV switch-mode dc power supply for an electron-beam gun that exploits these advantages was designed and tested. It uses four 100-kW, current-source-type dc-dc converters with inputs in parallel and outputs in series. The dc-dc converters operate at 20 kHz in the voltage regulator part and 10 kHz in the inverter, transformer, and output rectifier part of the circuit. Insulated gate bipolar transistors (IGBTs) are used as the power switches. Special techniques are used to protect the power supply and load against arcs and hard shorts. The power supply has an efficiency of 93%, an output voltage ripple of 1%, and fast dynamic response. In addition, it is nearly one-third the size of conventional power supplies.

  2. Conducted EMI Suppression in Plasma Cutting Power Supply

    Institute of Scientific and Technical Information of China (English)

    Abdolreza Esmaeli; Sun Li; Zhao Ke

    2005-01-01

    A systematic approach to the design of the conducted electromagnetic interference (EMI) filter of high-density plasma cutting power supply has been developed. Converter components have been accurately modeled, with parasitic elements extracted to reveal their impacts on the EMI noises. Circuit simulations have been used to analyze and minimize the EMI noises.Conducted EMI noise measurement and filter design of this power supply have been achieved which successfully satisfy the FCC class B limits in the frequency range from 150 kHz to 30 MHz.The analyses and experimental results show that the designed filter guarantees that the required attenuation will be achieved.

  3. RFX machine and power supply improvements for RFP advanced studies

    Energy Technology Data Exchange (ETDEWEB)

    Piovan, R. E-mail: piovan@igi.pd.cnr.it; Gnesotto, F.; Ortolani, S.; Baker, W.; Barana, O.; Bettini, P.; Cavazzana, R.; Chitarin, G.; Dal Bello, S.; De Lorenzi, A.; Fiorentin, P.; Gaio, E.; Grando, L.; Luchetta, A.; Manduchi, G.; Marchiori, G.; Marcuzzi, D.; Masiello, A.; Milani, F.; Peruzzo, S.; Pomaro, N.; Sonato, P.; Taliercio, C.; Toigo, V.; Zaccaria, P.; Zanotto, L.; Zollino, G

    2001-10-01

    Experimental results and theoretical studies call for Reversed Field Experiment (RFX) machine and power supply improvements to allow studies that go beyond those of a conventional Reversed Field Pinch (RFP) with passively stabilized turbulent MHD dynamo. The new paths opened by recent results in RFX and other RFP machines are introduced; then the goals and the design lines of the technical modifications of RFX, mainly addressed to improve the first wall, the plasma magnetic boundaries and to increase the operational flexibility of the toroidal field circuit power supply, are reported.

  4. Improvements in electric power supply in coal mines

    Energy Technology Data Exchange (ETDEWEB)

    Minovskii, Yu.P.; Nabokov, Eh.P.; Savel' ev, G.P.

    1985-01-01

    Reviews measures taken by major coal producing countries to increase output levels. Discusses research carried out into advance design of equipment in FRG, UK, USA and France and proposes establishment of central automatic control of electric power supply system in Soviet mines, improvement in underground power supply equipment, increase in reliability, stabilization of standby capacity in low voltage circuits, maintenance-free electrical equipment, and efficient spare part storage in underground workings. States that introduction of the proposed system (details are given) will ensure that Soviet mines will eventually reach the development level of foreign mines. 2 refs.

  5. A number of upgrades on RHIC power supply system

    Energy Technology Data Exchange (ETDEWEB)

    Mi, C. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Bruno, D. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Drozd, J. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Nolan, T. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Orsatti, F. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Heppener, G. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Di Lieto, A. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Schultheiss, C. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Samms, T. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Zapasek, R. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Sandberg, J. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.

    2015-05-03

    This year marks the 15th run for the Relativistic Heavy Ion Collider (RHIC). Operation of a reliable superconducting magnet power supply system is a key factor of an accelerator’s performance. Over the past 15 years, the RHIC power supply group has made many improvements to increase the machine availability and reduce failures. During these past 15 years of operating RHIC a lot of problems have been solved or addressed. In this paper some of the essential upgrades/improvements are discussed.

  6. Issues and future direction of thermal-hydraulics research and development in nuclear power reactors

    Energy Technology Data Exchange (ETDEWEB)

    Saha, P., E-mail: pradip.saha@ge.com [GE Hitachi Nuclear Energy, Wilmington, NC (United States); Aksan, N. [GRNSPG Group, University of Pisa (Italy); Andersen, J. [GE Hitachi Nuclear Energy, Wilmington, NC (United States); Yan, J. [Westinghouse Electric Co., Columbia, SC (United States); Simoneau, J.P. [AREVA, Lyon (France); Leung, L. [Atomic Energy of Canada Ltd., Chalk River, Ontario (Canada); Bertrand, F. [CEA, DEN, DER, F-13108 Saint-Paul-Lez-Durance (France); Aoto, K.; Kamide, H. [Japan Atomic Energy Agency, Chiyoda-ku, Tokyo (Japan)

    2013-11-15

    The paper archives the proceedings of an expert panel discussion on the issues and future direction of thermal-hydraulic research and development in nuclear power reactors held at the NURETH-14 conference in Toronto, Canada, in September 2011. Thermal-hydraulic issues related to both operating and advanced reactors are presented. Advances in thermal-hydraulics have significantly improved the performance of operating reactors. Further thermal-hydraulics research and development is continuing in both experimental and computational areas for operating reactors, reactors under construction or ready for near-term deployment, and advanced Generation-IV reactors. As the computing power increases, the fine-scale multi-physics computational models, coupled with the systems analysis code, are expected to provide answers to many challenging problems in both operating and advanced reactor designs.

  7. Output Regulation of Large-Scale Hydraulic Networks with Minimal Steady State Power Consumption

    DEFF Research Database (Denmark)

    Jensen, Tom Nørgaard; Wisniewski, Rafal; De Persis, Claudio;

    2014-01-01

    that the system is overactuated is exploited for minimizing the steady state electrical power consumption of the pumps in the system, while output regulation is maintained. The proposed control actions are decentralized in order to make changes in the structure of the hydraulic network easy to implement.......An industrial case study involving a large-scale hydraulic network is examined. The hydraulic network underlies a district heating system, with an arbitrary number of end-users. The problem of output regulation is addressed along with a optimization criterion for the control. The fact...

  8. PEP-II Large Power Supplies Rebuild Program at SLAC

    CERN Document Server

    de Lira, Antonio C; Lipari, James J; da Silva Rafael, Fernando

    2005-01-01

    At PEP-II, seven large power supplies (LGPS) are used to power quad magnets in the electron-positron collider region. The LGPS ratings range from 72kW to 270kW, and were installed in 1997. They are unipolar off-line switch mode supplies, with a 6 pulse bridge rectifying 480VAC, 3-phase input power to yield 650VDC unregulated. This unregulated 650VDC is then input into one (or two) IGBT H-bridges, which convert the DC into PWM 16 kHz square wave AC. This high frequency AC drives the primary side of a step-down transformer followed by rectifiers and low pass filters. Over the years, these LGPS have presented many problems mainly in their control circuits, making it difficult to troubleshoot and affecting the overall accelerator availability. A redesign/rebuilding program for these power supplies was established under the coordination of the Power Conversion Department at SLAC. During the 2004 accelerator summer shutdown all the control circuits in these supplies were redesigned and replaced. A new PWM control b...

  9. The Design of the Parallel Switching Power Supply System

    Directory of Open Access Journals (Sweden)

    Bin Zhang

    2013-10-01

    Full Text Available This study introduces a parallel switching power supply system which is controlled by C8051F020 MCU. The system consists of DC/DC converter, voltage-controlled constant current source circuit, over-current protection circuit and auxiliary power supply. TPS54331 is used to constitute a highly efficient DC/DC converter, reducing the input DC voltage to supply the voltage-controlled constant current source circuit. The parallel current-sharing of the system is realized by the voltage-controlled constant current source circuit. The output current of the two parallel power supply can be adjusted by changing the control voltage. When the output current exceeds the set value, the system starts over-current protection circuit to cut off the power and delays to restore power automatically after a certain period of time. The test results show that the system is stable and reliable, easy to control and has a function of over-current protection and automatic recovery.

  10. Development of a heavy duty portable variable power supply (HPVPS)

    Science.gov (United States)

    Musa, Ahmad Zulfadli Bin; Lung, Chong Man; Abidin, Wan'Amirah Basyarah Binti Zainol

    2017-08-01

    This paper covers the innovation of a Heavy Duty Portable Variable Power Supply (HPVPS) in Jabatan Kejuruteraan Elektrik (JKE), Politeknik Mukah, Sarawak (PMU). This project consists of variable power supply which can vary the output from 1.2 V to 11.6V, AC pure wave inverter to convert DC to AC for the operation of low power home appliances and also used Li-on rechargeable batteries to store the electrical energy and additional feature that can be used to jump-start the batteries of the car. The main objective of this project is to make the user can operate the electronic devices anywhere whenever if no electricity while doing their lab activities. Most of the regulated power supply in JKE lab aged 9-10 years old and need periodical maintenance and need cost and also the unit can be used is not enough to support the whole class during lab activities. As a result, the P&P process will be facing the major problem in order to make the lab activities running smoothly. By development of the portable variable power supply, the P&P process is more efficient and very helpful.

  11. Power quality improvement in switched mode power supplies using ...

    African Journals Online (AJOL)

    user

    A SEPIC stores the energy in an inductor, and transfers that energy to the output storage capacitor. ..... 2011–2017. ... His areas of interest include power electronics, electrical machines and drives, renewable energy systems, active filters, ...

  12. Designing a Power Supply with Multiple Input Options

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Some electronic systems such as field communications equip-ment must be able to operate from a variety of power sources,forexample,worldwide universal AC (85—264V rms) or vehicle bat-tery power. These systems may also require backup power in casethe primary source is interrupted.The illustration shows a power supply that can operate fromthe AC line,from a 12V or 24V vehicle battery,or from an internal48V backup battery. For AC line use, a front end module accepts a

  13. Alternative power supply systems for remote industrial customers

    Science.gov (United States)

    Kharlamova, N. V.; Khalyasmaa, A. I.; Eroshenko, S. A.

    2017-06-01

    The paper addresses the problem of alternative power supply of remote industrial clusters with renewable electric energy generation. As a result of different technologies comparison, consideration is given to wind energy application. The authors present a methodology of mean expected wind generation output calculation, based on Weibull distribution, which provides an effective express-tool for preliminary assessment of required installed generation capacity. The case study is based on real data including database of meteorological information, relief characteristics, power system topology etc. Wind generation feasibility estimation for a specific territory is followed by power flow calculations using Monte Carlo methodology. Finally, the paper provides a set of recommendations to ensure safe and reliable power supply for the final customers and, subsequently, to provide sustainable development of the regions, located far from megalopolises and industrial centres.

  14. Development of a solar charged laboratory bench power supply

    Science.gov (United States)

    Ayara, W. A.; Omotosho, T. V.; Usikalu, M. R.; Singh, M. S. J.; Suparta, W.

    2017-05-01

    This product is an improvement on available DC laboratory bench power supply. It is capable of delivering low voltage Alternating Current (AC) and Direct Current (DC) to carry out basic laboratory experiment for both secondary schools and also at higher education institutions. The power supply is capable of delivering fixed DC voltages of 5V, 9V, 12V, variable voltage of between 1.25-30V and a 12V AC voltage. Also Incorporated is a USB port that allows for charging cell phones and other mobile devices, and a dedicated 12V DC output to power 5-7 Watt LED bulb to provide illumination in the laboratory for the instructor who may need to work at night in the absence of utility power.

  15. Bimode uninterruptible power supply compatibility in renewable hybrid energy systems

    Energy Technology Data Exchange (ETDEWEB)

    Bower, W. (Sandia National Labs., Albuquerque, NM (USA)); O' Sullivan, G. (Abacus Controls, Inc., Somerville, NJ (USA))

    1990-08-01

    Inverters installed in renewable hybrid energy systems are typically used in a stand-alone mode to supply ac power to loads from battery storage when the engine-generator is not being used. Similarities in topology and in the performance requirements of the standby uninterruptible power supply (UPS) system and the hybrid system suggest the UPS could be used in hybrid energy systems. Another alternative to inverters with add-on charging circuits or standby UPS hardware is the Bimode UPS. The bimode UPS uses common circuitry and power components for dc to ac inversion and battery charging. It also provides an automatic and nearly instantaneous ac power transfer function when the engine-generator is started or stopped. The measured operating and transfer characteristics of a bimode UPS in a utility system and in a hybrid system are presented. The applicability of the bimode UPS to hybrid systems and its compatibility in a PV/engine-generator hybrid system are given.

  16. Dual Power Supplies for PEP-II Injection Kickers

    Energy Technology Data Exchange (ETDEWEB)

    Olszewski, J; Decker, F.-J.; Iverson, R.H.; Kulikov, A.; Pappas, C.; /SLAC

    2005-05-25

    Originally the PEP-II injection kickers were powered by one power supply. Since the kicker magnets where not perfectly matched, the stored beam got excited by about 7% of the maximum kicker amplitude. This led to luminosity losses which were especially obvious for trickle injection when the detector is on for data taking. Therefore two independent power supplies with thyratrons in the tunnel next to the kicker magnet were installed. This also reduces the necessary power by about a factor of four since there are no long cables that have to be charged. The kickers are now independently adjustable to eliminate any non-closure of the kicker system and therefore excitation of the stored beam. Setup, commissioning and fine tuning of this system are discussed.

  17. Milliwatt radioisotope power supply for the PASCAL Mars surface stations

    Science.gov (United States)

    Allen, Daniel T.; Murbach, Marcus S.

    2001-02-01

    A milliwatt power supply is being developed based on the 1 watt Light-Weight Radioisotope Heater Unit (RHU), which has already been used to provide heating alone on numerous spacecraft. In the past year the power supply has been integrated into the design of the proposed PASCAL Mars Network Mission, which is intended to place 24 surface climate monitoring stations on Mars. The PASCAL Mars mission calls for the individual surface stations to be transported together in one spacecraft on a trajectory direct from launch to orbit around Mars. From orbit around Mars each surface station will be deployed on a SCRAMP (slotted compression ramp) probe and, after aerodynamic and parachute deceleration, land at a preselected location on the planet. During descent sounding data and still images will be accumulated, and, once on the surface, the station will take measurements of pressure, temperature and overhead atmospheric optical depth for a period of 10 Mars years (18.8 Earth years). Power for periodic data acquisition and transmission to orbital then to Earth relay will come from a bank of ultracapacitors which will be continuously recharged by the radioisotope power supply. This electronic system has been designed and a breadboard built. In the ultimate design the electronics will be arrayed on the exterior surface of the radioisotope power supply in order to take advantage of the reject heat. This assembly in turn is packaged within the SCRAMP, and that assembly comprises the surface station. An electrically heated but otherwise prototypical power supply was operated in combination with the surface station breadboard system, which included the ultracapacitors. Other issues addressed in this work have been the capability of the generator to withstand the mechanical shock of the landing on Mars and the effectiveness of the generator's multi-foil vacuum thermal insulation. .

  18. A High Power Test Method for Pattern Magnet Power Supplies with Capacitor Banks

    Science.gov (United States)

    Kurimoto, Yoshinori; Morita, Yuichi; Sagawa, Ryu; Shimogawa, Tetsushi; Miura, Kazuki

    In the J-PARC Main Ring (MR), we plan to increase the beam intensity from 230 to 750 kW. To achieve this, the synchrotron repetition period must be shortened from 2.48 s to approximately 1 s using new power supplies for the main magnets. We are currently researching and developing new power supplies with large capacitor banks. Such banks are needed to reduce the power variation at the main grid in the J-PARC site for future operations with shorter repetition periods. However, it is very difficult to test the new power supplies at their rated power before installation. This is because the power handled by the power supplies used for the J-PARC MR main magnets is too high to be tested in factories or laboratories. To overcome this problem, we suggest a test method involving the use of two capacitor banks. In this method, two power supplies and a small inductive load are connected between two capacitor banks. By controlling the energy flow between the two capacitor banks in this setup, the received power and inductive load can be kept very small. This article describes the details of the control method and the results of the test experiment using a mini-model power supply.

  19. Minimizing the mass of a potential railgun power supply

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, D.E.; Noel, A.P.; Clements, W.D. (IAP Research, Inc., Dayton, OH (United States))

    1991-01-01

    This paper reports on the design of a pulsed power supply to deliver 5 MJ at 1 MA at 1 shot per second to a railgun. The supply stores energy at low current in the primary of the hydrogen-cooled transformer. A switch opens the primary circuit to transfer energy to the secondary, stepping the current up to 1 MA. The authors are studying the relationship between the transformer and switch to determine how the total power supply mass can be minimized. Vacuum interrupters and gate-turn-off thyristors are used in the switch. Switch mass dominates the system, accounting for 85% of the total mass. The switch must absorb the uncoupled energy of the transformer. Low transformer coupling requires large capacitors. Even with high coupling, capacitors account for 75 to 85% of the switch mass. If transformer coupling increases, the uncoupled energy decreases, resulting in low capacitor mass.

  20. Development of Discrete Power Supply with Charge Pump Method for High Powered Sonar System

    Directory of Open Access Journals (Sweden)

    Kristian Ismail

    2012-07-01

    Full Text Available Power supply is one of the electronic devices that can provide electric energy for electronic systems or other systems. There are several types of power supplies that can be applied depend on the requirement and functions. One example is the use of power supply for sonar systems. Sonar system is a device which can be used to detect a target under water. The sonar system is an electronic circuit that requires a power supply with specific characteristics when the sonar functions as a transmitter and a receiver in the specific span time (when on and the specific lag time (when off. This paper discusses the design of power supply for high-powered sonar systems with discrete methods in which high power supply is only applied when the acoustic waves radiated under water. Charge pump was used to get the appropriate output voltage from lower input voltage. Charge pump utilized a combination of series and parallel connections of capacitors. The working mode of this power supply used the lag time as the calculation of time to charge charge pump capacitors in parallel while the span time was used for the calculation of discharging the charge pump capacitors in series.

  1. NASA Ames Research Center 60 MW Power Supply Modernization

    Science.gov (United States)

    Choy, Yuen Ching; Ilinets, Boris V.; Miller, Ted; Nagel, Kirsten (Technical Monitor)

    2001-01-01

    The NASA Ames Research Center 60 MW DC Power Supply was built in 1974 to provide controlled DC power for the Thermophysics Facility Arc Jet Laboratory. The Power Supply has gradually losing reliability due to outdated technology and component life limitation. NASA has decided to upgrade the existing rectifier modules with contemporary high-power electronics and control equipment. NASA plans to complete this project in 2001. This project includes a complete replacement of obsolete thyristor stacks in all six rectifier modules and rectifier bridge control system. High power water-cooled thyristors and freewheeling diodes will be used. The rating of each of the six modules will be 4000 A at 5500 V. The control firing angle signal will be sent from the Facility Control System to six modules via fiberoptic cable. The Power Supply control and monitoring system will include a Master PLC in the Facility building and a Slave PLC in each rectifier module. This system will also monitor each thyristor level in each stack and the auxiliary equipment.

  2. Design of Controller for New EAST Fast Control Power Supply

    Institute of Scientific and Technical Information of China (English)

    HUANG Haihong; YIN Ming; WANG Haixin

    2014-01-01

    The effectiveness of the magnetic confinement of plasma can be improved by elongating the plasma cross-section in tokamak devices.But elongated plasma has vertical displacement instability,so a feedback control system is needed to restrain the plasma's vertical displacement.A fast control power supply is needed to excite the active feedback coils,which produces a magnetic field to control the plasma's displacement.With the development of EAST,the fast control power supply needs to keep on enhancing the fast response and output current.The structure of a new power supply is introduced in this paper.The method of multiple inverters paralleled with the current sharing reactor is presented to meet the need for large current and fast control.According to the design demands of the EAST fast control power supply,the adjuster of the current close loop is applied to the inverter,which can advance its ability to restrain the loop current in low frequency and DC output.The result of the experiment confirms the validity of the proposed scheme and control strategy.

  3. 47 CFR 80.860 - Reserve power supply.

    Science.gov (United States)

    2010-10-01

    .... (f) The cooling system of each internal combustion engine used as a part of the reserve power supply... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Technical Equipment Requirements for Cargo Vessels Not Subject to Subpart W §...

  4. Grid Connected Power Supplies for Particle Accelerator Magnets

    DEFF Research Database (Denmark)

    Nielsen, Rasmus Ørndrup

    and smaller converter size. A high efficiency converter based on Silicon Carbide switching devices is also presented exhibiting above 96 % efficiency for the entire power range. Finally reliability issues are considered as the reliability of a particle accelerator supply is of utmost importance. Particle...

  5. A cascaded online uninterruptible power supply using reduced semiconductor

    DEFF Research Database (Denmark)

    Zhang, Lei; Loh, Poh Chiang; Gao, Feng

    2011-01-01

    A cascaded online uninterruptible power supply (UPS) is proposed here that uses 25% lesser semiconductor, as compared to its traditional H-bridge cascaded precedence. Unlike other component-saving configurations where compromises are unavoidable, almost no performance degradations and constraints...

  6. Essays in market power mitigation and supply function equilibrium

    Science.gov (United States)

    Subramainam, Thiagarajah Natchie

    Market power mitigation has been an integral part of wholesale electricity markets since deregulation. In wholesale electricity markets, different regions in the US take different approaches to regulating market power. While the exercise of market power has received considerable attention in the literature, the issue of market power mitigation has attracted scant attention. In the first chapter, I examine the market power mitigation rules used in New York ISO (Independent System Operator) and California ISO (CAISO) with respect to day-ahead and real-time energy markets. I test whether markups associated with New York in-city generators would be lower with an alternative approach to mitigation, the CAISO approach. Results indicate the difference in markups between these two mitigation rules is driven by the shape of residual demand curves for suppliers. Analysis of residual demand curves faced by New York in-city suppliers show similar markups under both mitigation rules when no one supplier is necessary to meet the demand (i.e., when no supplier is pivotal). However, when some supplier is crucial for the market to clear, the mitigation rule adopted by the NYISO consistently leads to higher markups than would the CAISO rule. This result suggest that market power episodes in New York is confined to periods where some supplier is pivotal. As a result, I find that applying the CAISOs' mitigation rules to the New York market could lower wholesale electricity prices by 18%. The second chapter of my dissertation focuses on supply function equilibrium. In power markets, suppliers submit offer curves in auctions, indicating their willingness to supply at different price levels. Although firms are allowed to submit different offer curves for different time periods, surprisingly many firms stick to a single offer curve for the entire day. This essentially means that firms are submitting a single offer curve for multiple demand realizations. A suitable framework to analyze

  7. Power supply system for negative ion source at IPR

    Energy Technology Data Exchange (ETDEWEB)

    Gahlaut, Agrajit; Sonara, Jashwant; Parmar, K G; Soni, Jignesh; Bandyopadhyay, M; Singh, Mahendrajit; Bansal, Gourab; Pandya, Kaushal; Chakraborty, Arun, E-mail: agrajit@ipr.res.i [Institute for Plasma Research, Gandhinagar, Gujarat - 382428 (India)

    2010-02-01

    The first step in the Indian program on negative ion beams is the setting up of Negative ion Experimental Assembly - RF based, where 100 kW of RF power shall be coupled to a plasma source producing plasma of density {approx}5 x 10{sup 12} cm{sup -3}, from which {approx} 10 A of negative ion beam shall be produced and accelerated to 35 kV, through an electrostatic ion accelerator. The experimental system is modelled similar to the RF based negative ion source, BATMAN presently operating at IPP, Garching, Germany. The mechanical system for Negative Ion Source Assembly is close to the IPP source, remaining systems are designed and procured principally from indigenous sources, keeping the IPP configuration as a base line. High voltage (HV) and low voltage (LV) power supplies are two key constituents of the experimental setup. The HV power supplies for extraction and acceleration are rated for high voltage ({approx}15 to 35kV), and high current ({approx} 15 to 35A). Other attributes are, fast rate of voltage rise (< 5ms), good regulation (< {+-}1%), low ripple (< {+-}2%), isolation ({approx}50kV), low energy content (< 10J) and fast cut-off (< 100{mu}s). The low voltage (LV) supplies required for biasing and providing heating power to the Cesium oven and the plasma grids; have attributes of low ripple, high stability, fast and precise regulation, programmability and remote operation. These power supplies are also equipped with over-voltage, over-current and current limit (CC Mode) protections. Fault diagnostics, to distinguish abnormal rise in currents (breakdown faults) with over-currents is enabled using fast response breakdown and over-current protection scheme. To restrict the fault energy deposited on the ion source, specially designed snubbers are implemented in each (extraction and acceleration) high voltage path to swap the surge energy. Moreover, the monitoring status and control signals from these power supplies are required to be electrically ({approx} 50k

  8. Photovoltaic power supply for telecommunication network components in remote areas

    Energy Technology Data Exchange (ETDEWEB)

    Steinhueser, A.; Schulz, W.; Schmidt, H.; Roth, W. [Fraunhofer Inst. for Solar Energy Systems ISE, Freiburg (Germany)

    2000-07-01

    In general, telecommunication facilities do not allow much flexibility in the choice of location; the main criterion is that the facility must work with 100% availability and reliability. Corresponding to the wide spectrum of locations, the applied power supply technologies are very diverse: grid connection, diesel generators, photovoltaics (PV), fuel cells, thermoelectric converters and wind generators. The first three types of technology have been used by the telecommunications industry for decades. The other options are at developmental stages between laboratory samples and limited series production. The traditional approach to supply power remote from the grid is by using diesel generators and storage batteries. This means high power ratings, but also high prices and a high maintenance demand. The convergence of telecommunications networks, i.e. overlap of the cabled network and radio cellular networks, with its enormous demand for installation sites, introduces new demands on power supplies: they must be reliable, maintenance-free, inexpensive, flexibly adaptable to widely divergent technologies. At two examples, a PV-hybrid system for a repeater station for cellular phones and a PV powered intelligent information system, the advantages that offer PV off-grid solutions in the system design are shown. (orig.)

  9. Overview on the power supply systems for plasma instabilities control

    Energy Technology Data Exchange (ETDEWEB)

    Toigo, V., E-mail: vanni.toigo@igi.cnr.it [Consorzio RFX - EURATOM - ENEA Association, C.so Stati Uniti 4, 35127 Padova (Italy); Gaio, E.; Piovan, R.; Barp, M.; Bigi, M.; Ferro, A.; Finotti, C.; Novello, L.; Recchia, M.; Zamengo, A.; Zanotto, L. [Consorzio RFX - EURATOM - ENEA Association, C.so Stati Uniti 4, 35127 Padova (Italy)

    2011-10-15

    The paper presents an overview on the power supply (PS) systems for plasma instabilities control in fusion experiments, based on active control coils. First, the MHD instabilities and the approach to their control in Tokamaks and Reversed Field Pinches (RFPs) are described. Then, the features of MHD modes controls presently used in fusion experiments are reviewed. For the control systems based on active coils fed by fast power supplies, the typical requirements in terms of power, dynamics, accuracy and delay are summarized and discussed. Then, a survey on the technology available to design these types of PSs is given, together with the most suitable circuit topologies and guidelines for the design, on the basis of solutions adopted in existing experiments.

  10. Energy efficiency criteria in uninterruptible power supply selection

    Energy Technology Data Exchange (ETDEWEB)

    Moreno-Munoz, A.; Flores-Arias, J.M.; Bellido-Outerino, F.J.; Gil-de-Castro, A. [Universidad de Cordoba, Area de Electronica, Escuela Politecnica Superior, Leonardo Da Vinci Bldg., Campus de Rabanales, Ctra. Nacional IV, Km 369, E-14071 Cordoba (Spain); Rosa, Juan Jose Gonzalez de la [Universidad de Cadiz, Area de Electronica, Dpto. ISA, TE y Electronica, Escuela Politecnica SuperiorAvda, Ramon Puyol, S/N, E-11202 Algeciras-Cadiz (Spain)

    2011-04-15

    With the generalized use of microelectronic devices, server computers and other susceptible equipment, the subject related to power quality (PQ) and its relationship to vulnerability of high performance plants are becoming an increasing concern to the industry. This paper addresses how uninterruptible power supply (UPS), particularly when configured in distributed DC mode, can become an energy efficient (EE) solution in high-tech buildings, especially when integrated with complimentary PQ measures. The paper is based on PQ audits conducted at different high-tech industries over the last years. It was found that the main problems for the equipment installed were voltage sags (or dips). Among all categories of electrical disturbances, voltage sags and momentary interruptions are the nemeses of the automated industrial process. The paper analyzes the capabilities of modern electronic power supplies and the convenience of embedded solution. Finally it is addresses the role of the Standards on the protection of electronic equipment and the implications for the final costumer. (author)

  11. Analysis of heat transfer in portable power supply

    Science.gov (United States)

    Abdullah, Mohd Azman; Ali, Ahmad Nazrin

    2016-03-01

    Portable power supply (PPS) is developed based on the necessity in supplying instant power to support domestic appliances during power shortage or in remote area. In this paper, the heat transfer inside the PPS is analyzed and demonstrated by temperature change during battery charging and discharging. The computational fluid dynamic (CFD) model of the PPS battery and housing are developed. The heat flow inside the PPS is studied at different conditions of battery and air flows. The increment of the temperature inside the PPS could cause the PPS system to damage and unsafe. Few elements are manipulated for the study, such as battery positions, holedimensions and fan models in order toimprove the design of PPS. Experimental approach is also conducted to validate the temperature and heat transfer in the PPS.

  12. Water-hydraulic power transmission for offshore wind farms

    NARCIS (Netherlands)

    Diepeveen, N.F.B.; Jarquin Laguna, A.; Kempenaar, A.S.

    2012-01-01

    The current state of the art of offshore wind turbine power transmission technology is expensive, heavy and maintenance intensive. The Delft Offshore Turbine project considers a radically new concept for power transmission in an offshore wind farm: using seawater as power transmission medium. For th

  13. Water-hydraulic power transmission for offshore wind farms

    NARCIS (Netherlands)

    Diepeveen, N.F.B.; Jarquin Laguna, A.; Kempenaar, A.S.

    2012-01-01

    The current state of the art of offshore wind turbine power transmission technology is expensive, heavy and maintenance intensive. The Delft Offshore Turbine project considers a radically new concept for power transmission in an offshore wind farm: using seawater as power transmission medium. For

  14. Active Power Flow Optimization of Industrial Power Supply with Regard to the Transmission Line Conductor Heating

    Directory of Open Access Journals (Sweden)

    Leyzgold D.Yu.

    2015-04-01

    Full Text Available This article studies the problem of the transmission line conductor heating effect on the active power flows optimization in the local segment of industrial power supply. The purpose is to determine the optimal generation rating of the distributed power sources, in which the power flow values will correspond to the minimum active power losses in the power supply. The timeliness is the need to define the most appropriate rated power values of distributed sources which will be connected to current industrial power supply. Basing on the model of active power flow optimization, authors formulate the description of the nonlinear transportation problem considering the active power losses depending on the transmission line conductor heating. Authors proposed a new approach to the heating model parameters definition based on allowable current loads and nominal parameters of conductors as part of the optimization problem. Analysis of study results showed that, despite the relatively small active power losses reduction to the tune 0,45% due to accounting of the conductors heating effect for the present configuration of power supply, there are significant fluctuations in the required generation rating in nodes of the network to 9,32% within seasonal changes in the outer air temperature. This fact should be taken into account when selecting the optimum power of distributed generation systems, as exemplified by an arbitrary network configuration.

  15. Proposal for the award of a contract for the supply of uninterruptible power supplies for the Computer Centre

    CERN Document Server

    2005-01-01

    This document concerns the award of a contract for the supply of uninterruptible power supplies (UPS) for the Computer Centre. The Finance Committee is invited to agree to the negotiation of a contract with MGE-UPS (FR), the lowest bidder, for the supply of uninterruptible power supplies for the Computer Centre for a total amount of 527 661 euros (818 714 Swiss francs), not subject to revision. The rate of exchange used is that stipulated in the tender.

  16. Optimisation of Working Areas in Discrete Hydraulic Power Take off-system for Wave Energy Converters

    DEFF Research Database (Denmark)

    Hansen, Anders Hedegaard; Hansen, Rico Hjerm; Pedersen, Henrik C.

    2012-01-01

    Fluid power is the leading technology in Power Take Off(PTO) systems in Wave Energy Converters(WEC’s), due to the capability of generating high force at low velocity. However, as hydraulic force controlling system may suffer from large energy losses the efficiency of the hydraulic PTO systems may...... be a limiting factor for wave energy. Therefore, a secondary controlled force system has been proposed as PTO element for WEC’s. This paper investigates the configuration of a multi-chamber cylinder utilising two common pressure lines. By usage of model based optimisation an optimal number and size of working...

  17. Reducing Conductor Usage in Superconducting Machines by Multiple Power Supplies

    DEFF Research Database (Denmark)

    Jensen, Bogi Bech; Mijatovic, Nenad; Abrahamsen, Asger Bech

    2013-01-01

    This paper presents and applies a method of reducing the needed amount of superconductor in a superconducting machine by supplying the superconductor from multiple power supplies. The method is presented and validated experimentally in a constructed prototype. Thereafter, a superconducting tape...... is tested experimentally for allowable current density in a flux density spanning from 0 to 16 T and a temperature range from 5 K to 85 K. Using the experimental data from the superconductor, the proposed method is applied to minimize the usage of superconductor in a 10-MW superconducting direct drive wind...

  18. 7 CFR 1710.303 - Power cost studies-power supply borrowers.

    Science.gov (United States)

    2010-01-01

    ... this section. (Approved by the Office of Management and Budget under control number 0572-0032) ... AND GUARANTEES Long-Range Financial Forecasts § 1710.303 Power cost studies—power supply borrowers. (a... forecast required by § 1710.302. (b) A power cost study shall include the following basic elements: (1)...

  19. Digitally Controlled Envelope Tracking Power Supply for an RF Power Amplifier

    DEFF Research Database (Denmark)

    Jakobsen, Lars Tønnes; Andersen, Michael Andreas E.

    2007-01-01

    due to clock frequency quantization. An envelope tracking power supply for an RF Power Amplifier (RFPA) can help improve system efficiency by reducing the power consumption of the RFPA. To show the advantage of the DiSOM over traditional counter based Digital PWM modulators two designs were compared...

  20. TEDS Base Station Power Amplifier using Low-Noise Envelope Tracking Power Supply

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Wendelboe; Andersen, Michael A. E.

    2009-01-01

    This paper demonstrates a highly linear and efficient TETRA enhanced data service (TEDS) base-station RF power amplifier (RFPA). Based on the well-known combination of an envelope tracking (ET) power supply and a linear class-A/B RFPA, adequate adjacent channel power ratio (ACPR) and wideband noise...

  1. Development of a photovoltaic power supply for wireless sensor networks.

    Energy Technology Data Exchange (ETDEWEB)

    Harvey, Matthew R.; Kyker, Ronald D.

    2005-06-01

    This report examines the design process of a photovoltaic (solar) based power supply for wireless sensor networks. Such a system stores the energy produced by an array of photovoltaic cells in a secondary (rechargeable) battery that in turn provides power to the individual node of the sensor network. The goal of such a power supply is to enable a wireless sensor network to have an autonomous operation on the order of years. Ideally, such a system is as small as possible physically while transferring the maximum amount of available solar energy to the load (the node). Within this report, there is first an overview of current solar and battery technologies, including characteristics of different technologies and their impact on overall system design. Second is a general discussion of modeling, predicting, and analyzing the extended operation of a small photovoltaic power supply and setting design parameters. This is followed by results and conclusions from the testing of a few basic systems. Lastly, some advanced concepts that may be considered in order to optimize future systems will be discussed.

  2. Novel wave power analysis linking pressure-flow waves, wave potential, and the forward and backward components of hydraulic power.

    Science.gov (United States)

    Mynard, Jonathan P; Smolich, Joseph J

    2016-04-15

    Wave intensity analysis provides detailed insights into factors influencing hemodynamics. However, wave intensity is not a conserved quantity, so it is sensitive to diameter variations and is not distributed among branches of a junction. Moreover, the fundamental relation between waves and hydraulic power is unclear. We, therefore, propose an alternative to wave intensity called "wave power," calculated via incremental changes in pressure and flow (dPdQ) and a novel time-domain separation of hydraulic pressure power and kinetic power into forward and backward wave-related components (ΠP±and ΠQ±). Wave power has several useful properties:1) it is obtained directly from flow measurements, without requiring further calculation of velocity;2) it is a quasi-conserved quantity that may be used to study the relative distribution of waves at junctions; and3) it has the units of power (Watts). We also uncover a simple relationship between wave power and changes in ΠP±and show that wave reflection reduces transmitted power. Absolute values of ΠP±represent wave potential, a recently introduced concept that unifies steady and pulsatile aspects of hemodynamics. We show that wave potential represents the hydraulic energy potential stored in a compliant pressurized vessel, with spatial gradients producing waves that transfer this energy. These techniques and principles are verified numerically and also experimentally with pressure/flow measurements in all branches of a central bifurcation in sheep, under a wide range of hemodynamic conditions. The proposed "wave power analysis," encompassing wave power, wave potential, and wave separation of hydraulic power provides a potent time-domain approach for analyzing hemodynamics.

  3. Mathematical model for calculation of the heat-hydraulic modes of heating points of heat-supplying systems

    Science.gov (United States)

    Shalaginova, Z. I.

    2016-03-01

    The mathematical model and calculation method of the thermal-hydraulic modes of heat points, based on the theory of hydraulic circuits, being developed at the Melentiev Energy Systems Institute are presented. The redundant circuit of the heat point was developed, in which all possible connecting circuits (CC) of the heat engineering equipment and the places of possible installation of control valve were inserted. It allows simulating the operating modes both at central heat points (CHP) and individual heat points (IHP). The configuration of the desired circuit is carried out automatically by removing the unnecessary links. The following circuits connecting the heating systems (HS) are considered: the dependent circuit (direct and through mixing elevator) and independent one (through the heater). The following connecting circuits of the load of hot water supply (HWS) were considered: open CC (direct water pumping from pipelines of heat networks) and a closed CC with connecting the HWS heaters on single-level (serial and parallel) and two-level (sequential and combined) circuits. The following connecting circuits of the ventilation systems (VS) were also considered: dependent circuit and independent one through a common heat exchanger with HS load. In the heat points, water temperature regulators for the hot water supply and ventilation and flow regulators for the heating system, as well as to the inlet as a whole, are possible. According to the accepted decomposition, the model of the heat point is an integral part of the overall heat-hydraulic model of the heat-supplying system having intermediate control stages (CHP and IHP), which allows to consider the operating modes of the heat networks of different levels connected with each other through CHP as well as connected through IHP of consumers with various connecting circuits of local systems of heat consumption: heating, ventilation and hot water supply. The model is implemented in the Angara data

  4. A battery-powered high-current power supply for superconductors

    CERN Document Server

    Wake, M; Suda, K

    2002-01-01

    Since superconductors do not require voltages, a high-current power supply could run with low power if the voltage is sufficiently reduced. Even a battery-powered power supply could give as much as 2,000A for a superconductor. To demonstrate this hypothesis, a battery-powered 2,000A power supply was constructed. It uses an IGBT chopper and Schottky diode together with a specially arranged transformer to produce a high current with low voltage. Testing of 2,000A operation was performed for about 1.5 hr using 10 car batteries. Charging time for this operation was 8 hr. Ramping control was smooth and caused no trouble. Although the IGBT frequency ripple of 16.6 kHz was easily removed using a passive filter, spike noise remained in the output voltage. This ripple did not cause any trouble in operating a pancake-type inductive superconducting load. (author)

  5. Advanced superconducting power cable for MV urban power supply

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Frank [Nexans Deutschland GmbH, Hannover (Germany); Merschel, Frank [RWE Deutschland AG, Essen (Germany); Noe, Mathias [Karlsruhe Institute of Technology, Karlsruhe (Germany)

    2015-07-01

    In recent years the technology of superconducting power cable systems has progressed such that the technical hurdles preparing for commercial applications have been mastered. Several field tests of large scale prototypes for the applications of superconducting cables as well as superconducting fault current limiters have been successfully accomplished and the technology of such systems is ready for commercialization. The presentation will give a detailed overview of the German AmpaCity project. An overview will be given on the development, manufacturing and installation of the 10 kV, 40 MVA HTS system consisting of a fault current limiter and of a 1 km cable in the city of Essen. Since it is the first time that a one kilometer HTS cable system is installed together with an HTS fault current limiter in a real grid application between two substations within a city center area, AmpaCity serves as a lighthouse project. In addition it is worldwide the longest installed HTS cable system so far. It is expected that relatively large technical advances will be made in the future of the comparatively new HTS technology, which in turn will bring associated cost reductions. For this reason, the AmpaCity pilot project in the downtown area of Essen in Germany will be an important step on the way to achieving more widespread application of HTS technology.

  6. Testing of Uninterruptible Power Supplies with nonlinear loads

    Science.gov (United States)

    Heydt, Gerald; Briggs, Steve; Holcomb, Franklin; Edgar, Daiva

    1994-09-01

    Uninterruptible power supplies (UPS's) are used to provide power to sensitive and critical loads when the commercial supply has been interrupted. These loads may be nonlinear, which in the military often includes communications equipment, adjustable speed drives, fluorescent lighting, and mainframe and small computers. Most electrical characteristics of UPS's are not currently subject to codes and standards, and there are no military specifications for UPS's. Existing standards assume that UPS's will be operated with linear loads. Since most UPS systems are operated with nonlinear loads, there is concern that UPSs will suffer degraded performance or failure when operated with these loads. This work developed a test methodology by which UPS systems can be tested and their susceptibility to nonlinear loads quantified. The tests measure load transfer, efficiency, heating, load support, voltage regulation, and isolation. Several commercially available UPS systems are recommended for testing.

  7. Modern Solutions for Automation of Electrical Traction Power Supply Systems

    Directory of Open Access Journals (Sweden)

    Ana Mihaela Andreica

    2011-09-01

    Full Text Available This paper presents modern solutions for the automation of the electrical traction power supply system used in urban public transport (trams, trolleybuses and subway trains. The monitoring and control of this process uses SCADA distributed architectures, grouped around a central point (dispatcher who controls all field sensors, transmitters and actuators using programmable logical controllers. The presented applications refer to the Bucharest electrical transport infrastructure.

  8. Systems for uninterrupted power supply; USV - ein starkes Stueck Sicherheit

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, D.; Soelter, W. [AEG SVS GmbH, Warstein-Belecke (Germany)

    1999-09-01

    The millennium bug is only one of the many potential hazards in information technology. Systems for uninterrupted power supply offer a solution. [German] Alle Welt spricht vom Jahr-2000-Problem (Y2K). Die Meinungen dazu reichen von Horror-Szenarien bis hin zum Ignorieren dieses Problems. Dabei steht fest: Das Jahr-2000-Problem ist nur eines unter vielen Gefahrenpotentialen fuer die Informationstechnik. Dabei lassen sich alle Stoerfaktoren, die aus der Energieversorgung resultieren mit einer USV beseitigen. USV sichern Geschaeftsablaeufe und Fertigungsprozesse. (orig.)

  9. Analytical and experimental investigation of chlorine decay in water supply systems under unsteady hydraulic conditions

    DEFF Research Database (Denmark)

    Aisopou, Angeliki; Stoianov, Ivan; Graham, Nigel;

    2013-01-01

    coefficient is defined which depends upon the absolute value of shear stress and the rate of change of shear stress for quasi-unsteady and unsteady-state flows. By coupling novel instrumentation technologies for continuous hydraulic monitoring and water quality sensors for in-pipe water quality sensing...

  10. A Multi-channel AC Power Supply Controller

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    A multi-channel AC power Supply controler developed recently by us was introdueed briefty in this paper.This controller is a computer controlled multi-electronic-switch device.The controller contains 16 independent channels in a standard box(440W×405D×125H mm).There is an electronic switch in each channel,the rated load power is≤1 kW.The main function of the controller is to set the state of electronic switch(ON/OFF)

  11. optimal selection of hydraulic turbines for small hydro electric power ...

    African Journals Online (AJOL)

    eobe

    Results from the analysis showed that turbines that gave maximum and minimum power urbines that ..... turbine application range charts have been developed to assist with .... Results from the study shows that thorough technical knowledge ...

  12. Development of compact rapid charging power supply for capacitive energy storage in pulsed power drivers

    Science.gov (United States)

    Sharma, Surender Kumar; Shyam, Anurag

    2015-02-01

    High energy capacitor bank is used for primary electrical energy storage in pulsed power drivers. The capacitors used in these pulsed power drivers have low inductance, low internal resistance, and less dc life, so it has to be charged rapidly and immediately discharged into the load. A series resonant converter based 45 kV compact power supply is designed and developed for rapid charging of the capacitor bank with constant charging current up to 150 mA. It is short circuit proof, and zero current switching technique is used to commute the semiconductor switch. A high frequency resonant inverter switching at 10 kHz makes the overall size small and reduces the switching losses. The output current of the power supply is limited by constant on-time and variable frequency switching control technique. The power supply is tested by charging the 45 kV/1.67 μF and 15 kV/356 μF capacitor banks. It has charged the capacitor bank up to rated voltage with maximum charging current of 150 mA and the average charging rate of 3.4 kJ/s. The output current of the power supply is limited by reducing the switching frequency at 5 kHz, 3.3 kHz, and 1.7 kHz and tested with 45 kV/1.67 μF capacitor bank. The protection circuit is included in the power supply for over current, under voltage, and over temperature. The design details and the experimental testing results of the power supply for resonant current, output current, and voltage traces of the power supply with capacitive, resistive, and short circuited load are presented and discussed.

  13. Zhaotong Accelerated the Construction Progress of 700,000 t/a Hydraulic Power Aluminum Project

    Institute of Scientific and Technical Information of China (English)

    2015-01-01

    Zhaotong Municipal Government signed the"Framework Agreement on Hydraulic Power Aluminum Project for the Recovery&Reconstruction; after Ludian 6.5 grade Earthquake"with Yunnan Metallurgical Group Co.,Ltd recently,both sides confirmed the construction of 700,000 t/a electrolytic aluminum production line in Zhaoyang Industrial Park.

  14. Controlling chaos in a satellite power supply subsystem

    Science.gov (United States)

    Macau, E. E. N.; Ramos Turci, L. F.; Yoneyama, T.

    2008-12-01

    In this work, we show that chaos control techniques can be used to increase the region that can be efficiently used to supply the power requests for an artificial satellite. The core of a satellite power subsystem relies on its DC/DC converter. This is a very nonlinear system that presents a multitude of phenomena ranging from bifurcations, quasi-periodicity, chaos, coexistence of attractors, among others. The traditional power subsystem design techniques try to avoid these nonlinear phenomena so that it is possible to use linear system theory in small regions about the equilibrium points. Here, we show that chaos control can be used to efficiently extend the applicability region of the satellite power subsystem when it operates in regions of high nonlinearity.

  15. 275 C Downhole Switched-Mode Power Supply

    Energy Technology Data Exchange (ETDEWEB)

    Chris Hutchens; Vijay Madhuravasal

    2008-08-31

    A vee-square (V2) control based controller IC is developed for a switch mode power supply capable of operating at extreme temperature/harsh environment conditions. A buck type regulator with silicon carbide power junction field effect transistors (JFET) as power devices is used to analyze the performance of controller. Special emphases are made on the analog sub-blocks--voltage reference, operational transconductance amplifier and comparator as individual building blocks. Transformer coupled gate drives and high temperature operable magnetic cores and capacitors are identified and tested for use in the design. Conventional ceramic chip packaging of ICs combined with lead carrier type mounting of passive filter components is introduced for hybrid packaging of the complete product. The developed SMPS is anticipated to support the operation of down-hole microcontrollers and other electronics devices that require low/medium power filtered dc inputs over an operating temperature of 275 C.

  16. Static Analysis of High-Performance Fixed Fluid Power Drive with a Single Positive-Displacement Hydraulic Motor

    Directory of Open Access Journals (Sweden)

    O. F. Nikitin

    2015-01-01

    Full Text Available The article deals with the static calculations in designing a high-performance fixed fluid power drive with a single positive-displacement hydraulic motor. Designing is aimed at using a drive that is under development and yet unavailable to find and record the minimum of calculations and maximum of existing hydraulic units that enable clear and unambiguous performance, taking into consideration an available assortment of hydraulic units of hydraulic drives, to have the best efficiency.The specified power (power, moment and kinematics (linear velocity or angular velocity of rotation parameters of the output element of hydraulic motor determine the main output parameters of the hydraulic drive and the useful power of the hydraulic drive under development. The value of the overall efficiency of the hydraulic drive enables us to judge the efficiency of high-performance fixed fluid power drive.The energy analysis of a diagram of the high-performance fixed fluid power drive shows that its high efficiency is achieved when the flow rate of fluid flowing into each cylinder and the magnitude of the feed pump unit (pump are as nearly as possible.The paper considers the ways of determining the geometric parameters of working hydromotors (effective working area or working volume, which allow a selection of the pumping unit parameters. It discusses the ways to improve hydraulic drive efficiency. Using the principle of holding constant conductivity allows us to specify the values of the pressure losses in the hydraulic units used in noncatalog modes. In case of no exact matching between the parameters of existing hydraulic power modes and a proposed characteristics of the pump unit, the nearest to the expected characteristics is taken as a working version.All of the steps allow us to create the high-performance fixed fluid power drive capable of operating at the required power and kinematic parameters with high efficiency.

  17. Layouts of trigeneration plants for centralized power supply

    Science.gov (United States)

    Klimenko, A. V.; Agababov, V. S.; Il'ina, I. P.; Rozhnatovskii, V. D.; Burmakina, A. V.

    2016-06-01

    One of the possible and, under certain conditions, sufficiently effective methods for reducing consumption of fuel and energy resources is the development of plants for combined generation of different kinds of energy. In the power industry of Russia, the facilities have become widespread in which the cogeneration technology, i.e., simultaneous generation of electric energy and heat, is implemented. Such facilities can use different plants, viz., gas- and steam-turbine plants and gas-reciprocating units. Cogeneration power supply can be further developed by simultaneously supplying the users not only with electricity and heat but also with cold. Such a technology is referred to as trigeneration. To produce electricity and heat, trigeneration plants can use the same facilities that are used in cogeneration, namely, gas-turbine plants, steam-turbine plants, and gas-reciprocating units. Cold can be produced in trigeneration plants using thermotransformers of various kinds, such as vaporcompression thermotransformers, air thermotransformers, and absorption thermotransformers, that operate as chilling machines. The thermotransformers can also be used in the trigeneration plants to generate heat. The main advantage of trigeneration plants based on gas-turbine plants or gas-reciprocating units over cogeneration plants is the increased thermodynamic power supply efficiency owing to utilization of the waste-gas heat not only in winter but also in summer. In the steam-turbine-based trigeneration plants equipped with absorption thermotransformers, the enhancement of the thermodynamic power supply efficiency is determined by the increase in the heat extraction load during the nonheating season. The article presents calculated results that demonstrate higher thermodynamic efficiency of a gas-turbine-based plant with an absorption thermotransformer that operates in the trigeneration mode compared with a cogeneration gas-turbine plant. The structural arrangements of trigeneration

  18. GAS AND OIL POWER DISTRIBUTION RATIO OF A NEW HYDRAULIC BREAKER

    Institute of Scientific and Technical Information of China (English)

    ZHAO Hongqiang; LI Meixiang; GAO Bin; HE Qinghua

    2007-01-01

    The working principle of a new hydraulic breaker operated jointly by gas and hydraulic flow which has a reasonable structure, high efficiency and long piston life-span, is analyzed, and the optimal power distribution ratio of the sealed nitrogen gas to the high-pressure oil in the process of piston impacting is studied. Through theoretical analysis, optimization simulation and detailed calculation, it is determined that the impact system has optimal mechanical performance and highest efficiency when the distribution ratio Φis between 0.3 and 0.5. The theoretical result is also verified by repeated tests.

  19. Station power supply by residual steam of Fugen

    Energy Technology Data Exchange (ETDEWEB)

    Kamiya, Y.; Kato, H.; Hattori, S. (Power Reactor and Nuclear Fuel Development Corp., Tokyo (Japan))

    1981-09-01

    In the advanced thermal reactor ''Fugen'', when the sudden decrease of load more than 40% occurs due to the failure of power system, the turbine regulating valve is rapidly shut, and the reactor is brought to scrum. However, the operation of turbo-generators is continued with the residual steam in the reactor, and the power for inside the station is supplied for 30 sec by the limiting timer, then the power-generating plant is automatically stopped. The reasons why such design was adopted are to reduce manual operation at the time of emergency, to continue water supply for cooling the reactor and to maintain the water level in the steam drum, and to reduce steam release from the safety valve and the turbine bypass valve. The output-load unbalance relay prevents the everspeed of the turbo-generator when load decreased suddenly, but when the failure of power system is such that recovers automatically in course of time, it does not work. The calculation for estimating the dynamic characteristics at the time of the sole operation within the station is carried out by the analysis code FATRAC. The input conditions for the calculation and the results are reported. Also the dynamic characteristics were actually tested to confirm the set value of the limiting timer and the safe working of turbine and generator trips. The estimated and tested results were almost in agreement.

  20. Magnet power supply regulation comments: 240 kW and 500 kW magnet power supplies

    Energy Technology Data Exchange (ETDEWEB)

    Visser, A.T.

    1993-03-01

    This note is written for users who need better than about 100 ppm regulated magnet fields in electromagnets. A magnet excitation current regulation of 100 ppm is generally specified to obtain this field regulation, but there are many other variables, in addition to magnet excitation that can change the magnet field. The effects of these other variables are often overlooked or underestimated. If things do not work out, the power supply often gets blamed. A field regulation of 100 ppm requires that the power supply regulates substantially better than 100 ppm and that the effects of other variables are limited. Before we can talk about regulation we must define what regulation is. Power supplies can be regulated for current or voltage. We will only talk about current regulation, since that is the regulation mode used to establish precisely regulated magnetic fields in electromagnets. It is assumed that the same current value will always produce the same corresponding magnetic field value. Later on we will discuss that this assumption is not correct.

  1. Analyzing Power Supply and Demand on the ISS

    Science.gov (United States)

    Thomas, Justin; Pham, Tho; Halyard, Raymond; Conwell, Steve

    2006-01-01

    Station Power and Energy Evaluation Determiner (SPEED) is a Java application program for analyzing the supply and demand aspects of the electrical power system of the International Space Station (ISS). SPEED can be executed on any computer that supports version 1.4 or a subsequent version of the Java Runtime Environment. SPEED includes an analysis module, denoted the Simplified Battery Solar Array Model, which is a simplified engineering model of the ISS primary power system. This simplified model makes it possible to perform analyses quickly. SPEED also includes a user-friendly graphical-interface module, an input file system, a parameter-configuration module, an analysis-configuration-management subsystem, and an output subsystem. SPEED responds to input information on trajectory, shadowing, attitude, and pointing in either a state-of-charge mode or a power-availability mode. In the state-of-charge mode, SPEED calculates battery state-of-charge profiles, given a time-varying power-load profile. In the power-availability mode, SPEED determines the time-varying total available solar array and/or battery power output, given a minimum allowable battery state of charge.

  2. Review and Comparison of Power Management Approaches for Hybrid Vehicles with Focus on Hydraulic Drives

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Karbaschian

    2014-05-01

    Full Text Available The main advantage of hybrid powertrains is based on the efficient transfer of power and torque from power sources to the powertrain as well as recapturing of reversible energies without effecting the vehicle performance. The benefits of hybrid hydraulic powertrains can be better utilized with an appropriate power management. In this paper, different types of power management algorithms like off-line and on-line methods are briefly reviewed and classified. Finally, the algorithms are evaluated and compared. Therefore, different related criteria are evaluated and applied.

  3. Optimized Envelope Tracking Power Supply for Tetra2 Base Station RF Power Amplifier

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Wendelboe; Andersen, Michael Andreas E.

    2008-01-01

    An ultra-fast tracking power supply (UFTPS) for envelope tracking in a 50kHz 64-QAM Tetra2 base station power amplification system is demonstrated. A simple method for optimizing the step response of the PID+PD sliding-mode control system is presented and demonstrated, along with a PLL-based scheme...

  4. Thermal Impact Analysis of Circulating Current in High Power Modular Online Uninterruptible Power Supplies Application

    DEFF Research Database (Denmark)

    Zhang, Chi; Guerrero, Josep M.; Vasquez, Juan Carlos

    2015-01-01

    In a modular uninterruptible power supplies (UPS), each DC/AC module was designed to work in a circular way considering the reliability and power stress issues of the whole system. Thus unsynchronized PWMs will occur if any of the DC/AC modules is plugged in or out of the system at any time...

  5. Battery requirements for uninterruptible power-supply applications

    Science.gov (United States)

    Brownlie, G. D.

    There is an expanding market for small-to-medium capacity secondary batteries for use in uninterruptible power supplies (UPSs). UPSs are commonly used to provide protected power to computer installations, point-of sale terminals, and essential telecommunications equipment. The capacity of currently available UPSs is, typically, from 500 VA to several hundred kVa, with power-backup from ten minutes to one hour at full load. All UPSs incorporate secondary batteries; usually sealed lead/acid cells. Battery requirements include: high reliability; extended operating life; tolerance to extended float charging; and good, deep-discharge characteristics at high discharge rates. Recent research and development experiences in the design of a range of UPSs is described and the need for batteries optimised for UPS applications is highlighted.

  6. LVP modeling and dynamic characteristics prediction of a hydraulic power unit in deep-sea

    Science.gov (United States)

    Cao, Xue-peng; Ye, Min; Deng, Bin; Zhang, Cui-hong; Yu, Zu-ying

    2013-03-01

    A hydraulic power unit (HPU) is the driving "heart" of deep-sea working equipment. It is critical to predict its dynamic performances in deep-water before being immerged in the seawater, while the experimental tests by simulating deep-sea environment have many disadvantages, such as expensive cost, long test cycles, and difficult to achieve low-temperature simulation, which is only used as a supplementary means for confirmatory experiment. This paper proposes a novel theoretical approach based on the linear varying parameters (LVP) modeling to foresee the dynamic performances of the driving unit. Firstly, based on the varying environment features, dynamic expressions of the compressibility and viscosity of hydraulic oil are derived to reveal the fluid performances changing. Secondly, models of hydraulic system and electrical system are accomplished respectively through studying the control process and energy transfer, and then LVP models of the pressure and flow rate control is obtained through the electro-hydraulic models integration. Thirdly, dynamic characteristics of HPU are obtained by the model simulating within bounded closed sets of varying parameters. Finally, the developed HPU is tested in a deep-sea imitating hull, and the experimental results are well consistent with the theoretical analysis outcomes, which clearly declare that the LVP modeling is a rational way to foresee dynamic performances of HPU. The research approach and model analysis results can be applied to the predictions of working properties and product designs for other deep-sea hydraulic pump.

  7. The Power Supply System for the J-TEXT Poloidal Field

    Institute of Scientific and Technical Information of China (English)

    ZHANG Ming; ZHUANG Ge; YU Kexun; QiU Shengshun; PAN Yuan

    2009-01-01

    Joint-TEXT(J-TEXT)is a medium-sized tokamak constructed at Huazhong University of Science and Technology.At present,the poloidal field power supply consists of three subsystem sets,namely Ohmic heating field power supply,vertical field power supply,and horizontal field power supply.The structure and function of the poloidal field(PF)power supply aus well as the updated control system of the power supply is described.The new scheme uses the realtime feedback control method for the poloidal field power supply.The experimental results show that the poloidal field energized by poloidal field power supply meets the J-TEXT operational requirement perfectly.

  8. Research of Reliable Power Supply Schemes for OOO Gazprom Production Yamburg Gas Field

    Directory of Open Access Journals (Sweden)

    Askarov Alisher

    2015-01-01

    Full Text Available In article the analysis of substation electric part for the enterprises an oil and gas complex power supply is carried out: structure and switchgear schemes, uninterrupted reserve sources structure. Recommendations for power supply reliability are made.

  9. The electrohydraulic balance of the solar heat storage with autonomous power supply

    Directory of Open Access Journals (Sweden)

    M. K. Marahtanov

    2014-01-01

    Full Text Available The introduction of the paper emphasizes an increasingly important role of alternative power sources nowadays. At the same time, a solar collector (suntrap is one of the most frequent techniques to use the solar energy. It is an absorber that picks up solar radiation and heats a heat carrier circulating in the close loop. Then the heat is transferred to the heat accumulator that is integrated in the hot-tap water system (HWS.The paper presents a prospective circuit of the solar collector. It differs from the traditional one because, in addition to absorbing panel, it uses photoconverters to generate electric power for the circulating pump. The advantage of this system is that for operation such a solar energy converter has no need in external power sources, i.e. it is autonomous. The need to calculate the essential thermo-physical parameters that ensure no-break system operation was stated as a main objective of the work.The suggested circuit has a photocell panel to convert solar radiation into dc voltage of 12 V. In case of a lack of the solar energy an accumulator battery can be used for feeding. To ensure the no-break supply of power an adaptor is offered.To calculate a density distribution of solar radiation a sine law is offered depending on the time of day and geographical locality. This dependence was used to obtain the expressions for calculating the water temperature in boiler over daytime.Further, the calculations have been done for the operating conditions under which an efficient heat exchange will be provided with the minimum consumption of electric power for the heat carrier circulation in the first loop. For this purpose, a pump power was calculated depending on consumption and hydraulic losses of head in the pipeline. As a minimum required consumption the value has been chosen at which a laminar flow regime changes to the turbulent one because of the most efficient heat exchange being both in collector and in heat accumulator

  10. Powering Up” for the 21st Century: The Power Supply Industry in Major Transition

    Institute of Scientific and Technical Information of China (English)

    ArnoldN.Alderman

    2005-01-01

    The power supply industry is changing more today than ever before. From business composition to architectures, design methods, sourcing, geographic composition and infrastructure, every element of the power supply industry is changing. The challenges are dramatic, with solutions having long term impact. An overview is presented of the power supply industry today based on the author's industry association work, experience as a supplier, and discussions with industry leaders. Since power supplies is such a broad subject, the paper's focus is on some key aspects of the industry that may have wide interest to readers and participants. The major trends, market drivers, and issues are examined with some basic conclusions and challenges cited. The objective is to provide the reader with 1) a better overall impression of the state of the power supply industry is today 2) some insight into what the transitional driving elements are and 3) some ideas for assisting in the transitioning movements. The comments are mainly regarding North America and Europe, however these trends are affecting the Asian and Japanese regions.

  11. Composite Energy Storage System with Photovoltaic Power Generation and Uninterruptible Power Supply Function

    OpenAIRE

    Jung-Min Kwon

    2013-01-01

    A composite energy storage system (CESS) that includes a photovoltaic (PV) power generation and an uninterruptible power supply (UPS) function is proposed. This system has three operating modes, namely, a grid-connected inverter mode, a grid-connected rectifier mode, and an islanding mode. This system is composed of a boost converter, a three-phase inverter/rectifier, a bidirectional DC/DC converter, and thyristor switches. The boost converter extracts maximum power from the PV panels and sen...

  12. Climate protection and reliability of supply. Development of a sustainable power supply concept; Klimaschutz und Versorgungssicherheit. Entwicklung einer nachhaltigen Stromversorgung

    Energy Technology Data Exchange (ETDEWEB)

    Klaus, Thomas; Loreck, Charlotte; Mueschen, Klaus

    2009-09-15

    Germany, like other states, committed itself to sustainable development in the Rio declaration of 1992. The boundary conditions for this are set by nature itself, whose laws must be respected if goals like reliability of supply and economic efficiency are to be achieved. This study of the Federal Environmental Office shows how sustainable power supply can be achieved. It is possible to combine climate protection, reliability of supply and economic efficiency, even without nuclear power and without constructing new conventional power plants that do not have the function of combined heat and power generation. (orig.)

  13. Power shifts in the Australian agrifood supply chain

    OpenAIRE

    McKinna, David

    2011-01-01

    Over the past two years, the oligopsony of Australia’s big two supermarkets has been put under the spotlight. Woolworths was the dominant retailer, powering ahead of Coles which was lost in the haze of a dysfunctional management team and a poor business model. With the arrival of Coles’ new team from the UK, the sleeping tiger has leapt into battle to recover years of lost time. The Coles recovery strategy and Woolworths defensive response has thrown agrifood supply chains into disarray. Milk...

  14. Klystron switching power supplies for the Internation Linear Collider

    Energy Technology Data Exchange (ETDEWEB)

    Fraioli, Andrea; /Cassino U. /INFN, Pisa

    2009-12-01

    The International Linear Collider is a majestic High Energy Physics particle accelerator that will give physicists a new cosmic doorway to explore energy regimes beyond the reach of today's accelerators. ILC will complement the Large Hadron Collider (LHC), a proton-proton collider at the European Center for Nuclear Research (CERN) in Geneva, Switzerland, by producing electron-positron collisions at center of mass energy of about 500 GeV. In particular, the subject of this dissertation is the R&D for a solid state Marx Modulator and relative switching power supply for the International Linear Collider Main LINAC Radio Frequency stations.

  15. Ablation response testing of simulated radioisotope power supplies

    Science.gov (United States)

    Lutz, Steven A.; Chan, Chris C.

    1994-05-01

    Results of an experimental program to assess the aerothermal ablation response of simulated radioisotope power supplies are presented. Full-scale general purpose heat source, graphite impact shell, and lightweight radioisotope heater unit test articles are all tested without nuclear fuel in simulated reentry environments. Convective stagnation heating, stagnation pressure, stagnation surface temperature, surface recession profile, and weight loss measurements are obtained for diffusion-limited and sublimation ablation conditions. The recession profile and weight loss measurements show an effect of surface features on the stagnation face. The surface features alter the local heating which in turn affects the local ablation.

  16. Development of insulated gate bipolar transistor-based power supply for elemental copper vapour laser

    Indian Academy of Sciences (India)

    R K Mishra; S V Nakhe; G N Tiwari; J K Mittal

    2010-11-01

    The elemental copper vapour laser is a widely used laser from a family of metal vapour lasers for applications such as dye laser pumping, micromachining etc. In this paper, we report the development and performance of IGBT-based pulsed power supply that replaced conventional thyratron-based power supply for 4.7 cm diameter, 150 cm long copper vapour laser. The laser tube delivered an average power of 51 W, which with conventional power supply was giving 40 W. The IGBT-based power supply offers considerable reduction in the running cost of the laser. It is more user-friendly when compared with the conventional power supply.

  17. DC uninterrupted power supply having instantaneous switching followed by low impedance switching

    Science.gov (United States)

    Hammond, Russell E.; Northup, Robert L.; Shimp, Alan G.

    1991-10-01

    An uninterruptible power supply is provided that incorporates switching circuitry permitting a path for instantaneous DC backup power to be supplied to a voltage-declining primary power supply bus. Once the instantaneous transition is made, battery power is switched to a low impedance path to provide long-term battery power delivery to the bus. At a point where the backup batteries no longer supply useful power to a load, disabling circuitry disconnects the batteries from the load so that excessive draining of the batteries does not result in irreversible battery damage. The uninterruptible power supply of the invention further includes an automatic battery charging circuitry that seeks to maintain the power supply batteries at optimal charge level. To enable an operator to adequately assess battery charge condition, the invention provides battery test circuitry that causes a simulated load to appear at the power supply batteries. Visual representations are then made as to battery status.

  18. AC Power Routing System in Home Based on Demand and Supply Utilizing Distributed Power Sources

    Directory of Open Access Journals (Sweden)

    Takashi Hikihara

    2011-04-01

    Full Text Available To help reduce consumption of fossil fuels, renewable, natural and distributed power sources are being adopted. These alternative energy sources inevitably show fluctuations in the amount of output power, frequency, and voltage. The suppression of such fluctuations is a key issue to avoid disturbances in power grids. A similar situation arises as far as the regulation of in-home power flow is concerned. We focus on the quality of supplied and demanded power in particular. In this paper, an in-home power distribution system based on information of power is proposed. The system is developed in order to integrate power dispatch and communication. The experimental results show the feasibility of new flexible and efficient power management approaches.

  19. Self-organizing numerical models of transient processes in water supply hydraulic structures of energy industries

    Directory of Open Access Journals (Sweden)

    N.V. Arefyev

    2013-10-01

    Full Text Available Currently, there is an increase of diversity in the design of complex hydraulic structures. Thus there is a need to establish adequate mathematical models and software with complete description of processes. These models should be focused on certain classes of problems, which statements may change during the simulation. So, in our opinion, so-called self-organizing simulation models are perspective, they adapt to changes in the operating practice of the objects that require rapid adjustments in the boundary conditions and the field of simulation. Results of development of self-adapting complexes of numerical models, permitting calculation of complex water passageway systems with varying flow regime on separate parts (discharge; movement on the dry bottom, provided hydraulic head in free-flow downstream tunnel etc.. Presented system traces the movement of modeling area boundaries (when filling and dumping water passage sections and chooses the appropriate boundary condition with changing flow regime on the border of modelling area of the flow (free-flowing weir – drowned weir.Given results of numerical simulation of real systems make it possible to consider proposed approach as efficient.

  20. Application of Wavelet-based Active Power Filter in Accelerator Magnet Power Supply

    CERN Document Server

    Xiaoling, Guo

    2013-01-01

    As modern accelerators demand excellent stability to magnet power supply (PS), it is necessary to decrease harmonic currents passing magnets. Aim at depressing rappel current from PS in Beijing electron-positron collider II, a wavelet-based active power filter (APF) is proposed in this paper. APF is an effective device to improve the quality of currents. As a countermeasure to these harmonic currents, the APF circuit generates a harmonic current, countervailing harmonic current from PS. An active power filter based on wavelet transform is proposed in this paper. Discrete wavelet transform is used to analyze the harmonic components in supply current, and active power filter circuit works according to the analysis results. At end of this paper, the simulation and experiment results are given to prove the effect of the mentioned Active power filter.

  1. Design and evaluation of hydraulic baffled-channel PAC contactor for taste and odor removal from drinking water supplies.

    Science.gov (United States)

    Kim, Young-Il; Bae, Byung-Uk

    2007-05-01

    Based on the concept of hydraulic flocculator, a baffled-channel powdered activated carbon (PAC) contactor, placed before the rapid-mixing basin, was designed and evaluated for removal of taste and odor (T&O) in drinking water. PAC adsorption kinetic tests for raw water samples were conducted for selection of design parameters related to contact time and degree of mixing. Within the tested range of velocity gradient (G) from 18 to 83s(-1), mixing had a relatively minor effect on the adsorption kinetics of the PAC. The hydrodynamic characteristics of the pilot-scale horizontally and vertically baffled-channel PAC contactor were investigated by tracer tests. It was found that the plug flow fractions of vertically baffled-channel PAC contactor (vBPC) were higher than those of the horizontally baffled-channel PAC contactor (hBPC) for the same bend width or bend height. However, the hBPC seems to be more appropriate than the vBPC in terms of construction and maintenance. The geosmin and MIB removal rate increased with the number of baffles, PAC dose and contact time increased regardless of bend width in the pilot-scale hBPC. The pair of full-scale hBPCs at Pohang water treatment plant, having a design capacity of 6.5x10(4)m(3)/d with 20min of hydraulic retention time with a safety factor of 2, was designed based on lab- and pilot-scale experimental results. Under a velocity gradient of 20s(-1), the number of baffles to be installed was calculated to be 20 with a space of about 2m between each baffle, resulting in a hydraulic head loss through the contactor of about 0.056m. The successful application of hBPC for T&O removal from drinking water supplies should provide momentum for developing more effective treatment methods.

  2. Investigation of the interaction between the power electronic circuit and power supply systems

    Energy Technology Data Exchange (ETDEWEB)

    Beck, H.P.; Hermann, R.; Knuth, D.; Schwarzenau, R.

    1977-05-01

    Sources and consequences of the interaction between power electronics, power supply systems and telecommunications equipment were examined with the aid of measuring procedures and are presented here, using selected examples from traction and industrial drive technology. Apart from this the most important variables necessary to assess the power-line load, such as power factor, relative harmonic content and noise current, were calculated for conventional and low feedback effects converters taking various influencing factors into consideration. Another point of main emphasis in this research work is the analysis of the energy conditions prevailing in static converters for single-phase and three-phase supplies in particular in the case of pulsing methods for power control free of feedback effects. The methods and circuits for compensation and balancing of surge loads are described in detail in accordance with their technological significance. In the field of static high speed reactive power compensation with thyristor-controlled power capacitors new circuits and control techniques were developed. Work in the field of filter circuits reveals new application possibilities in power supply-systems with a high load of harmonic currents. Innovated noise current-reducing converter-wiring and controlled tuned capacitor banks can contribute to the prevention of mains resonance and other interferring factors influencing the performance of telecommunications equipment.

  3. Determination of minimum sample size for fault diagnosis of automobile hydraulic brake system using power analysis

    Directory of Open Access Journals (Sweden)

    V. Indira

    2015-03-01

    Full Text Available Hydraulic brake in automobile engineering is considered to be one of the important components. Condition monitoring and fault diagnosis of such a component is very essential for safety of passengers, vehicles and to minimize the unexpected maintenance time. Vibration based machine learning approach for condition monitoring of hydraulic brake system is gaining momentum. Training and testing the classifier are two important activities in the process of feature classification. This study proposes a systematic statistical method called power analysis to find the minimum number of samples required to train the classifier with statistical stability so as to get good classification accuracy. Descriptive statistical features have been used and the more contributing features have been selected by using C4.5 decision tree algorithm. The results of power analysis have also been verified using a decision tree algorithm namely, C4.5.

  4. Booster main magnet power supply, present operation and potential future upgrades

    Energy Technology Data Exchange (ETDEWEB)

    Bajon, E.; Bannon, M.; Marneris, I.; Danowski, G.; Sandberg, J.; Savatteri, S.

    2011-03-28

    The Brookhaven Booster Main Magnet Power Supply (MMPS) is a 24 pulse thyristor control supply, rated at 5500 Amps, +/-2000 Volts, or 3000 Amps, +/-6000 Volts. The power supply is fed directly from the power utility and the peak magnet power is 18 MWatts. This peak power is seen directly at the incoming ac line. This power supply has been in operation for the last 18 years. This paper will describe the present topology and operation of the power supply, the feedback control system and the different modes of operation of the power supply. Since the power supply has been in operation for the last 18 years, upgrading this power supply is essential. A new power supply topology has been studied where energy is stored in capacitor banks. DC to DC converters are used to convert the dc voltage stored in the capacitor banks to pulsed DC voltage into the magnet load. This enables the average incoming power from the ac line to be constant while the peak magnet power is pulsed to +/- 18 MWatts. Simulations and waveforms of this power supply will be presented.

  5. Development of hydraulic power unit and accumulator charging circuit for electricity generation, storage and distribution

    Institute of Scientific and Technical Information of China (English)

    C.N.Okoye; JIANG Ji-hai; LIU Hai-chang

    2008-01-01

    It is the purpose of the present paper to convert hydraulic energy to electric energy and saves both the pressure and electrical energy for re - use during the next system upstroke using two secondary units coupled to induction motor to drive cylinder loads. During upstroke operation, the variable pump/motor (P/M) driven by both electric motor and the second (P/M) works as hydraulic pump and output flow to the cylinders which drive the load. During load deceleration, the cylinders work as pump while the operation of the two secondary units are reversed, the variable (P/M) works as a motor generating a torque with the electric motor to drive the other(P/M) which transforms mechanical energy to hydraulic energy that is saved in the accumulator. When the en-ergy storage capacity of the accumulator is attained as the operation continues, energy storage to the accumulator is thermostatically stopped while the induction motor begins to work as a generator and generates electricity that is stored in the power distribution unit. Simulations were performed using a limited PT2 Block, I.e. 2nd-ordertransfer function with limitation of slope and signal output to determine suitable velocity of the cylinder which will match high performance and system stability. A mathematical model suited to the simulation of the hydrau-lic accumulator both in an open-or close-loop system is presented. The quest for improvement of lower energy capacity storage, saving and re-utilization of the conventional accumulator resulting in the short cycle time usage of hydraulic accumulators both in domestic and industrial purposes necessitates this research. The outcome of the research appears to be very efficient for generating fluctuation free electricity, power quality and reliability, energy saving/reutilization and system noise reduction.

  6. On-Shore Central Hydraulic Power Generation for Wind and Tidal Energy

    Science.gov (United States)

    Jones, Jack A.; Bruce, Allan; Lim, Steven; Murray, Luke; Armstrong, Richard; Kimbrall, Richard; Cook-Chenault, Kimberly; DeGennaro, Sean

    2012-01-01

    Tidal energy, offshore wind energy, and onshore wind energy can be converted to electricity at a central ground location by means of converting their respective energies into high-pressure hydraulic flows that are transmitted to a system of generators by high-pressure pipelines. The high-pressure flows are then efficiently converted to electricity by a central power plant, and the low-pressure outlet flow is returned. The Department of Energy (DOE) is presently supporting a project led by Sunlight Photonics to demonstrate a 15 kW tidal hydraulic power generation system in the laboratory and possibly later submerged in the ocean. All gears and submerged electronics are completely eliminated. A second portion of this DOE project involves sizing and costing a 15 MW tidal energy system for a commercial tidal energy plant. For this task, Atlantis Resources Corporation s 18-m diameter demonstrated tidal blades are rated to operate in a nominal 2.6 m/sec tidal flow to produce approximately one MW per set of tidal blades. Fifteen units would be submerged in a deep tidal area, such as in Maine s Western Passage. All would be connected to a high-pressure (20 MPa, 2900 psi) line that is 35 cm ID. The high-pressure HEPG fluid flow is transported 500-m to on-shore hydraulic generators. HEPG is an environmentally-friendly, biodegradable, watermiscible fluid. Hydraulic adaptations to ORPC s cross-flow turbines are also discussed. For 15 MW of wind energy that is onshore or offshore, a gearless, high efficiency, radial piston pump can replace each set of top-mounted gear-generators. The fluid is then pumped to a central, easily serviceable generator location. Total hydraulic/electrical efficiency is 0.81 at full rated wind or tidal velocities and increases to 0.86 at 1/3 rated velocities.

  7. On-Shore Central Hydraulic Power Generation for Wind and Tidal Energy

    Science.gov (United States)

    Jones, Jack A.; Bruce, Allan; Lim, Steven; Murray, Luke; Armstrong, Richard; Kimbrall, Richard; Cook-Chenault, Kimberly; DeGennaro, Sean

    2012-01-01

    Tidal energy, offshore wind energy, and onshore wind energy can be converted to electricity at a central ground location by means of converting their respective energies into high-pressure hydraulic flows that are transmitted to a system of generators by high-pressure pipelines. The high-pressure flows are then efficiently converted to electricity by a central power plant, and the low-pressure outlet flow is returned. The Department of Energy (DOE) is presently supporting a project led by Sunlight Photonics to demonstrate a 15 kW tidal hydraulic power generation system in the laboratory and possibly later submerged in the ocean. All gears and submerged electronics are completely eliminated. A second portion of this DOE project involves sizing and costing a 15 MW tidal energy system for a commercial tidal energy plant. For this task, Atlantis Resources Corporation s 18-m diameter demonstrated tidal blades are rated to operate in a nominal 2.6 m/sec tidal flow to produce approximately one MW per set of tidal blades. Fifteen units would be submerged in a deep tidal area, such as in Maine s Western Passage. All would be connected to a high-pressure (20 MPa, 2900 psi) line that is 35 cm ID. The high-pressure HEPG fluid flow is transported 500-m to on-shore hydraulic generators. HEPG is an environmentally-friendly, biodegradable, watermiscible fluid. Hydraulic adaptations to ORPC s cross-flow turbines are also discussed. For 15 MW of wind energy that is onshore or offshore, a gearless, high efficiency, radial piston pump can replace each set of top-mounted gear-generators. The fluid is then pumped to a central, easily serviceable generator location. Total hydraulic/electrical efficiency is 0.81 at full rated wind or tidal velocities and increases to 0.86 at 1/3 rated velocities.

  8. Spanning tree-based algorithm for hydraulic simulation of large-scale water supply networks

    Directory of Open Access Journals (Sweden)

    Huan-feng DUAN

    2010-03-01

    Full Text Available With the purpose of making calculation more efficient in practical hydraulic simulations, an improved algorithm was proposed and was applied in the practical water distribution field. This methodology was developed by expanding the traditional loop-equation theory through utilization of the advantages of the graph theory in efficiency. The utilization of the spanning tree technique from graph theory makes the proposed algorithm efficient in calculation and simple to use for computer coding. The algorithms for topological generation and practical implementations are presented in detail in this paper. Through the application to a practical urban system, the consumption of the CPU time and computation memory were decreased while the accuracy was greatly enhanced compared with the present existing methods.

  9. A new digital pulse power supply in heavy ion research facility in Lanzhou

    Science.gov (United States)

    Wang, Rongkun; Chen, Youxin; Huang, Yuzhen; Gao, Daqing; Zhou, Zhongzu; Yan, Huaihai; Zhao, Jiang; Shi, Chunfeng; Wu, Fengjun; Yan, Hongbin; Xia, Jiawen; Yuan, Youjin

    2013-11-01

    To meet the increasing requirements of the Heavy Ion Research Facility in Lanzhou-Cooler Storage Ring (HIRFL-CSR), a new digital pulse power supply, which employs multi-level converter, was designed. This power supply was applied with a multi H-bridge converters series-parallel connection topology. A new control model named digital power supply regulator system (DPSRS) was proposed, and a pulse power supply prototype based on DPSRS has been built and tested. The experimental results indicate that tracking error and ripple current meet the requirements of this design. The achievement of prototype provides a perfect model for HIRFL-CSR power supply system.

  10. Un-interrupted DH supply in the event of an electric power failure

    Energy Technology Data Exchange (ETDEWEB)

    Frederiksen, Svend; Wollerstrand, Janusz; Ljunggren, Patrick. e-mail: svend.frederiksen@energy.lth.se

    2008-09-15

    State-of-the-art district heating technology possesses a potential for being capable of continuing to supply building heating in the event of an electric power failure of long duration, a potential that has hitherto largely been overlooked or ignored. In the case of direct connection of hydronic building radiator space heating systems to district heating networks, water circulation within the building can rather easily be maintained, as long as there is a circulation within the district heating network. But with indirect connection, providing hydraulic separation by means of a heat exchanger, the situation becomes more difficult, since circulation within the building will often depend upon an individual circulation pump driven by an electric motor. Nevertheless, as is demonstrated in the paper, in many cases a substantial natural circulation effect of the classical type, depending upon a water density differential, can be established. A further approach presented is a novel type of device comprising a small water turbine arranged to be driven by the district heating pressure differential across a substation. The turbine can deliver, by direct shaft connection or otherwise, enough energy to run the circulation pump. The two approaches can even be combined, such that probably a large share of all customers connected to a district heating grid could be supplied with full or almost full heating capacity, even at harsh weather conditions

  11. A new digital pulse power supply in heavy ion research facility in Lanzhou

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Rongkun, E-mail: wangrongkun@impcas.ac.cn [Institute of Modern Physics, Lanzhou, 730000 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Chen, Youxin; Huang, Yuzhen; Gao, Daqing; Zhou, Zhongzu; Yan, Huaihai [Institute of Modern Physics, Lanzhou, 730000 (China); Zhao, Jiang; Shi, Chunfeng; Wu, Fengjun [Institute of Modern Physics, Lanzhou, 730000 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Yan, Hongbin; Xia, Jiawen; Yuan, Youjin [Institute of Modern Physics, Lanzhou, 730000 (China)

    2013-11-01

    To meet the increasing requirements of the Heavy Ion Research Facility in Lanzhou-Cooler Storage Ring (HIRFL-CSR), a new digital pulse power supply, which employs multi-level converter, was designed. This power supply was applied with a multi H-bridge converters series-parallel connection topology. A new control model named digital power supply regulator system (DPSRS) was proposed, and a pulse power supply prototype based on DPSRS has been built and tested. The experimental results indicate that tracking error and ripple current meet the requirements of this design. The achievement of prototype provides a perfect model for HIRFL-CSR power supply system. -- Highlights: • The converters topology of series-parallel connection improves the power supply's performance. • The SOPC based on dual Nios II processors improves the real-time performance of system. • Pulse mode is implemented in digital power supply based on FPGA, with a smaller tracking error.

  12. Reactive Power Compensation and Harmonic Suppression for Power Supply System of HT-7U Superconductive Tokamak

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    In this paper, a strategy for the reactive power compensation and harmonic suppression of the power supply system in HT-7U superconductive Tokamak is proposed. The optimizedapproach is given in the parameters design for passive filter. Also a controlling method with fastresponse time and good accuracy is put forward for the compensator, which is more suitable forthe dynamic load.PAGS: 84.70.+p ,52.55. Fa, 84.30. Vn

  13. Statistical Power Supply Dynamic Noise Prediction in Hierarchical Power Grid and Package Networks

    OpenAIRE

    Piccinini, Gianluca; Graziano, Mariagrazia

    2008-01-01

    One of the most crucial high performance systems-on-chip design challenge is to front their power supply noise sufferance due to high frequencies, huge number of functional blocks and technology scaling down. Marking a difference from traditional post physical-design static voltage drop analysis, /a priori dynamic voltage drop/evaluation is the focus of this work. It takes into account transient currents and on-chip and package /RLC/ parasitics while exploring the power grid design solution s...

  14. Largest fluidized bed power plant unit for power and district heat supply for Berlin (Part 1)

    Energy Technology Data Exchange (ETDEWEB)

    Abroell, G.; Bade, H.; Bietz, K.H.; Jahn, P. (ABB Kraftwerke AG, Mannheim (Germany))

    1991-11-01

    The Berlin Power and Light Company (Bewag) has decided to install, on the inner city site of Moabit, for the supply of electricity and district heating, a new unit with circulating atmospheric fluidized bed combustion. The plant will be designed for a thermal capacity of 240 MW. The basis for this decision, and also the technical implementation, will be made public.

  15. A Switching-Mode Power Supply Design Tool to Improve Learning in a Power Electronics Course

    Science.gov (United States)

    Miaja, P. F.; Lamar, D. G.; de Azpeitia, M.; Rodriguez, A.; Rodriguez, M.; Hernando, M. M.

    2011-01-01

    The static design of ac/dc and dc/dc switching-mode power supplies (SMPS) relies on a simple but repetitive process. Although specific spreadsheets, available in various computer-aided design (CAD) programs, are widely used, they are difficult to use in educational applications. In this paper, a graphic tool programmed in MATLAB is presented,…

  16. Potential for deserts to supply reliable renewable electric power

    Science.gov (United States)

    Labordena, Mercè; Lilliestam, Johan

    2015-04-01

    To avoid dangerous climate change, the electricity systems must be decarbonized by mid-century. The world has sufficient renewable electricity resources for complete power sector decarbonization, but an expansion of renewables poses several challenges for the electricity systems. First, wind and solar PV power are intermittent and supply-controlled, making it difficult to securely integrate this fluctuating generation into the power systems. Consequently, power sources that are both renewable and dispatchable, such as biomass, hydro and concentrating solar power (CSP), are particularly important. Second, renewable power has a low power density and needs vast areas of land, which is problematic both due to cost reasons and due to land-use conflicts, in particular with agriculture. Renewable and dispatchable technologies that can be built in sparsely inhabited regions or on land with low competition with agriculture would therefore be especially valuable; this land-use competition greatly limits the potential for hydro and biomass electricity. Deserts, however, are precisely such low-competition land, and are at the same time the most suited places for CSP generation, but this option would necessitate long transmission lines from remote places in the deserts to the demand centers such as big cities. We therefore study the potential for fleets of CSP plants in the large deserts of the world to produce reliable and reasonable-cost renewable electricity for regions with high and/or rapidly increasing electricity demand and with a desert within or close to its borders. The regions in focus here are the European Union, North Africa and the Middle East, China and Australia. We conduct the analysis in three steps. First, we identify the best solar generation areas in the selected deserts using geographic information systems (GIS), and applying restrictions to minimize impact on biodiversity, soils, human heath, and land-use and land-cover change. Second, we identify

  17. Dynamics and design of a power unit with a hydraulic piston actuator

    Science.gov (United States)

    Misyurin, S. Yu.; Kreinin, G. V.

    2016-07-01

    The problem of the preselection of parameters of a power unit of a mechatronic complex on the basis of the condition for providing a required control energy has been discussed. The design of the unit is based on analysis of its dynamics under the effect of a special-type test conditional control signal. The specific features of the approach used are a reasonably simplified normalized dynamic model of the unit and the formation of basic similarity criteria. Methods of designing a power unit with a hydraulic piston actuator that operates in point-to-point and oscillatory modes have been considered.

  18. Design and testing of a 320 MW pulsed power supply

    Energy Technology Data Exchange (ETDEWEB)

    Schillig, J.B.; Boenig, H.J. [Los Alamos National Lab., NM (United States); Ferner, J.A. [National High Magnetic Field Lab., Tallahassee, FL (United States)] [and others

    1998-03-01

    For a 60 Tesla, 100 millisecond long pulse magnet five 64 MW (87.6 MVA) power converter modules have been installed. Each module provides a no-load voltage of 4.18 kV and a full load voltage of 3.20 kV at the rated current of 20 kA. The modules are connected to a 1,430 MVA/650 MJ inertial energy storage generator set, which is operated at 21 kV and frequencies between 60 and 42 Hz. They are designed to provide the rated power output for 2 seconds once every hour. Each module consists of two 21 kV/3.1 kV cast coil transformers and two 6-pulse rectifiers connected in parallel without an interphase reactor, forming a 12-pulse converter module. As far as possible standard high power industrial converter components were used, operated closer to their allowable limits. The converters are controlled by three programmable high speed controllers. In this paper the design of the pulsed converters, including control and special considerations for protection schemes with the converters supplying a mutually coupled magnet system, is detailed. Test results of the converters driving an ohmic-inductive load for 2 seconds at 20 kA and 3.2 kV are presented.

  19. Remote Area Power Supply (RAPS) load and resource profiles.

    Energy Technology Data Exchange (ETDEWEB)

    Giles, Lauren (Energetics, Inc., Washington, DC); Skolnik, Edward G. (Energetics, Inc., Washington, DC); Marchionini, Brian (Energetics, Inc., Washington, DC); Fall, Ndeye K. (Energetics, Inc., Washington, DC)

    2007-07-01

    In 1997, an international team interested in the development of Remote Area Power Supply (RAPS) systems for rural electrification projects around the world was organized by the International Lead Zinc Research Organization (ILZRO) with the support of Sandia National Laboratories (SNL). The team focused on defining load and resource profiles for RAPS systems. They identified single family homes, small communities, and villages as candidates for RAPS applications, and defined several different size/power requirements for each. Based on renewable energy and resource data, the team devised a ''strawman'' series of load profiles. A RAPS system typically consists of a renewable and/or conventional generator, power conversion equipment, and a battery. The purpose of this report is to present data and information on insolation levels and load requirements for ''typical'' homes, small communities, and larger villages around the world in order to facilitate the development of robust design practices for RAPS systems, and especially for the storage battery component. These systems could have significant impact on areas of the world that would otherwise not be served by conventional electrical grids.

  20. The influence of power in supply chain innovation; a case study of the Dutch wheat chain

    NARCIS (Netherlands)

    Pol, Hanneke; Visscher, Klaasjan

    2010-01-01

    The purpose of this article is to clarify the relation between the power structure of a supply chain and the possibilities to realize supply chain innovations. In an in-depth case study of the faltering start of an innovation trajectory in the Dutch wheat supply chain, we show that supply chain inno

  1. LVP Modeling and Dynamic Characteristics Prediction of A Hydraulic Power Unit in Deep-Sea

    Institute of Scientific and Technical Information of China (English)

    CAO Xue-peng; YE Min; DENG Bin; ZHANG Cui-hong; YU Zu-ying

    2013-01-01

    A hydraulic power unit (HPU) is the driving "heart" of deep-sea working equipment.It is critical to predict its dynamic performances in deep-water before being immerged in the seawater,while the experimental tests by simulating deep-sea environment have many disadvantages,such as expensive cost,long test cycles,and difficult to achieve low-temperature simulation,which is only used as a supplementary means for confirmatory experiment.This paper proposes a novel theoretical approach based on the linear varying parameters (LVP) modeling to foresee the dynamic performances of the driving unit.Firstly,based on the varying environment features,dynamic expressions of the compressibility and viscosity of hydraulic oil are derived to reveal the fluid performances changing.Secondly,models of hydraulic system and electrical system are accomplished respectively through studying the control process and energy transfer,and then LVP models of the pressure and flow rate control is obtained through the electro-hydraulic models integration.Thirdly,dynamic characteristics of HPU are obtained by the model simulating within bounded closed sets of varying parameters.Finally,the developed HPU is tested in a deep-sea imitating hull,and the experimental results are well consistent with the theoretical analysis outcomes,which clearly declare that the LVP modeling is a rational way to foresee dynamic performances of HPU.The research approach and model analysis results can be applied to the predictions of working properties and product designs for other deep-sea hydraulic pump.

  2. Development of high-stability magnet power supply

    Science.gov (United States)

    Choi, W. S.; Kim, M. J.; Jeong, I. W.; Kim, D. E.; Park, H. C.; Park, K. H.

    2016-06-01

    A very stable (≤10 ppm) magnet power supply (MPS) is required in an accelerator to achieve acceptable beam dynamics. Many factors affect the stability of an MPS, so design of the MPS requires much attention to noise-reduction schemes and to good processing of the signals from the feedback stage. This paper describes some design considerations for an MPS installed and operated in the Pohang Accelerator Laboratory: (1) control method, (2) oversampling technology, (3) ground isolation between hardware modules and (4) low-pass filter design to reduce the switching noise and rectifier ripple components, and shows the stability of three designed devices. The MPS design considerations were verified and validated in simulations and experiments. This paper also shows the relationship between stability and measurement aperture time of digital voltage meter 3458 A to measure stability of a current.

  3. Development of high-stability magnet power supply

    Energy Technology Data Exchange (ETDEWEB)

    Choi, W.S.; Kim, M.J.; Jeong, I.W. [Graduate School of Wind Energy, Pohang University of Science and Technology, 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 37673 (Korea, Republic of); Kim, D.E. [Pohang Accelerator Laboratory, Pohang University of Science and Technology, 80 Jigokro-127-beongil, Nam-gu, Pohang, Gyeongbuk 37673 (Korea, Republic of); Park, H.C. [Graduate School of Wind Energy, Pohang University of Science and Technology, 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 37673 (Korea, Republic of); Park, K.H. [Pohang Accelerator Laboratory, Pohang University of Science and Technology, 80 Jigokro-127-beongil, Nam-gu, Pohang, Gyeongbuk 37673 (Korea, Republic of)

    2016-06-21

    A very stable (≤10 ppm) magnet power supply (MPS) is required in an accelerator to achieve acceptable beam dynamics. Many factors affect the stability of an MPS, so design of the MPS requires much attention to noise-reduction schemes and to good processing of the signals from the feedback stage. This paper describes some design considerations for an MPS installed and operated in the Pohang Accelerator Laboratory: (1) control method, (2) oversampling technology, (3) ground isolation between hardware modules and (4) low-pass filter design to reduce the switching noise and rectifier ripple components, and shows the stability of three designed devices. The MPS design considerations were verified and validated in simulations and experiments. This paper also shows the relationship between stability and measurement aperture time of digital voltage meter 3458 A to measure stability of a current.

  4. Self-stabilizing unidirectional network algorithms by power-supply

    Energy Technology Data Exchange (ETDEWEB)

    Afek, Y.; Bremler, A. [Tel-Aviv Univ. (Israel)

    1997-06-01

    Power-supply, a surprisingly simple and new general paradigm for the development of self-stabilizing algorithms in different models, is introduced. The paradigm is exemplified by developing simple and efficient self-stabilizing algorithms for leader election and either BFS or DFS spanning tree constructions, in strongly-connected unidirectional and bidirectional dynamic networks (synchronous and asynchronous). The different algorithms stabilize in O(n) time in both synchronous and asynchronous networks without assuming any knowledge about the network topology or size, where n is the total number of nodes. Following the leader election algorithms we present a generic self-stabilizing spanning tree and/or leader election algorithm that produces a whole spectrum of new and efficient algorithms for these problems. Two variations that produce either a rooted Depth First Search tree or a rooted Breadth First Search tree are presented.

  5. 76 FR 4147 - Putnam-Cumberland, TN-Improve Power Supply

    Science.gov (United States)

    2011-01-24

    ... Putnam-Cumberland, TN--Improve Power Supply AGENCY: Tennessee Valley Authority. ACTION: Notice of intent... supply improvements in the Putnam and Cumberland region of east-central Tennessee. The purpose of the... approximately 16,000 miles of transmission lines. TVA supplies bulk electric power to Cumberland and...

  6. Theory and Practice on Grouping Oil Supply of Hydraulic System in Production Line%生产流水线液压系统分组供油的理论与实践

    Institute of Scientific and Technical Information of China (English)

    钟文辉

    2014-01-01

    对于多执行元件的生产流水线液压传动系统,分组供油是一种合理的选择。从分组供油需满足的基本要求出发,研究了回路设计、油泵选型、排量计算、系统效率、基本参数的设计计算等重要问题,据此提出基于液压系统效率的分组原则。并介绍了采用分组供油的方法,对浇铸生产线液压系统改造的成功实例,验证了文中的结论,为生产线液压系统的设计和改造提供参考。%Grouping oil supply is a reasonable selection to hydraulic power actuating system in multi-component production line. Considering the basic requirements of grouping oil supply,loop design,oil pump selection,displacement calculation,system effi-ciency,design calculation of basic parameters and so on were researched.On these grounds,group forming criterion was come up with based on hydraulic system efficiency.Using the method of grouping oil supply,a successful example of hydraulic system reforma-tion in casting production line was introduced,and the conclusion was validated.It can be used for reference in the design and refor-mation of hydraulic system in production line.

  7. The Environment Friendly Power Source for Power Supply of Mobile Communication Base Stations

    Science.gov (United States)

    Rudenko, N. V.; Ershov, V. V.; Evstafiev, V. V.

    2017-05-01

    The article describes the technical proposals to improve environmental and resource characteristics of the autonomous power supply systems of mobile communication base stations based on renewable energy sources, while ensuring the required reliability and security of power supply. These include: the replacement of diesel-generator with clean energy source - an electrochemical generator based on hydrogen fuel cells; the use of wind turbines with a vertical axis; use of specialized batteries. Based on the analysis of the know technical solutions, the structural circuit diagram of the hybrid solar-wind-hydrogen power plant and the basic principles of the algorithm of its work were proposed. The implementation of these proposals will improve the environmental and resource characteristics.

  8. Numerical modeling for the retrofit of the hydraulic cooling subsystems in operating power plant

    Science.gov (United States)

    AlSaqoor, S.; Alahmer, A.; Al Quran, F.; Andruszkiewicz, A.; Kubas, K.; Regucki, P.; Wędrychowicz, W.

    2017-08-01

    This paper presents the possibility of using the numerical methods to analyze the work of hydraulic systems on the example of a cooling system of a power boiler auxiliary devices. The variety of conditions at which hydraulic system that operated in specific engineering subsystems requires an individualized approach to the model solutions that have been developed for these systems modernizing. A mathematical model of a series-parallel propagation for the cooling water was derived and iterative methods were used to solve the system of nonlinear equations. The results of numerical calculations made it possible to analyze different variants of a modernization of the studied system and to indicate its critical elements. An economic analysis of different options allows an investor to choose an optimal variant of a reconstruction of the installation.

  9. Thermal Impact Analysis of Circulating Current in High Power Modular Online Uninterruptible Power Supplies Application

    DEFF Research Database (Denmark)

    Zhang, Chi; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2017-01-01

    In modular uninterruptible power supplies (UPSs), several DC/AC modules are required to work in parallel. This structure allows the system to be more reliable and flexible. These DC/AC modules share the same DC bus and AC critical bus. Module differences, such as filter inductor, filter capacitor......, control parameters, and so on, will make it possible for the potential zero sequence current to flow among the modules. This undesired type of circulating current will bring extra losses to the power semiconductor devices in the system, which should be paid special attention in high power application...

  10. Comparison of Power Supply Pumping of Switch-Mode Audio Power Amplifiers with Resistive Loads and Loudspeakers as Loads

    DEFF Research Database (Denmark)

    Knott, Arnold; Petersen, Lars Press

    2013-01-01

    Power supply pumping is generated by switch-mode audio power amplifiers in half-bridge configuration, when they are driving energy back into their source. This leads in most designs to a rising rail voltage and can be destructive for either the decoupling capacitors, the rectifier diodes...... in the power supply or the power stage of the amplifier. Therefore precautions are taken by the amplifier and power supply designer to avoid those effects. Existing power supply pumping models are based on an ohmic load attached to the amplifier. This paper shows the analytical derivation of the resulting...... waveforms and extends the model to loudspeaker loads. Measurements verify, that the amount of supply pumping is reduced by a factor of 4 when comparing the nominal resistive load to a loudspeaker. A simplified and more accurate model is proposed and the influence of supply pumping on the audio performance...

  11. A power supply error correction method for single-ended digital audio class D amplifiers

    Science.gov (United States)

    Yu, Zeqi; Wang, Fengqin; Fan, Yangyu

    2016-12-01

    In single-ended digital audio class D amplifiers (CDAs), the errors caused by power supply noise in the power stages degrade the output performance seriously. In this article, a novel power supply error correction method is proposed. This method introduces the power supply noise of the power stage into the digital signal processing block and builds a power supply error corrector between the interpolation filter and the uniform-sampling pulse width modulation (UPWM) lineariser to pre-correct the power supply error in the single-ended digital audio CDA. The theoretical analysis and implementation of the method are also presented. To verify the effectiveness of the method, a two-channel single-ended digital audio CDA with different power supply error correction methods is designed, simulated, implemented and tested. The simulation and test results obtained show that the method can greatly reduce the error caused by the power supply noise with low hardware cost, and that the CDA with the proposed method can achieve a total harmonic distortion + noise (THD + N) of 0.058% for a -3 dBFS, 1 kHz input when a 55 V linear unregulated direct current (DC) power supply (with the -51 dBFS, 100 Hz power supply noise) is used in the power stages.

  12. Experimental and Numerical Simulations Predictions Comparison of Power and Efficiency in Hydraulic Turbine

    Directory of Open Access Journals (Sweden)

    Laura Castro

    2011-01-01

    Full Text Available On-site power and mass flow rate measurements were conducted in a hydroelectric power plant (Mexico. Mass flow rate was obtained using Gibson's water hammer-based method. A numerical counterpart was carried out by using the commercial CFD software, and flow simulations were performed to principal components of a hydraulic turbine: runner and draft tube. Inlet boundary conditions for the runner were obtained from a previous simulation conducted in the spiral case. The computed results at the runner's outlet were used to conduct the subsequent draft tube simulation. The numerical results from the runner's flow simulation provided data to compute the torque and the turbine's power. Power-versus-efficiency curves were built, and very good agreement was found between experimental and numerical data.

  13. Operation of SST-1 TF power supply during SST-1 campaigns

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Dinesh Kumar, E-mail: dinesh@ipr.res.in; Vora, Murtuza M.; Ojha, Amit; Singh, Akhilesh Kumar; Bhavsar, Chirag

    2015-10-15

    Highlights: • SST-1 TF power supply is 12 pulse SCR converter circuit. • TF power supply protection, measurement and control scheme are explained. • Quench, emergency and normal shot process is explained and results of SST-1 campaigns are shown. • Dynamic control of TF current. • The paper shows the results of last ten SST-1 campaigns. - Abstract: SST-1 TF power supply provides the direct current for the required magnetic field of TF coil. TF power supply includes transformer, 12-pulse converter, bus bar, water-cooled cable, protection and measuring equipments, and isolator, VME DAC system and GUI software. TF power supply is operated through GUI software built in TCL/Tk. VME DAC system monitors the parameters, provides On/Off commands, voltage and current references and initiates predefined reference to emergency shutdown. The emergency shutdown is hardwired to TF power supply from central control. During quench power supply converter opens DCCB and dump resistor is connected in the circuit and VME DAC system acquires bus bar voltage, dump voltage and dump current. Operation of TF power supply also requires monitoring of SCR and transformer temperature and water flow rate of water-cooled cable during high current long pulse shot. Before start up of TF power supply a quench simulation is performed to check the readiness of protection. This paper describes pre startup operation, normal shot operation, emergency and quench process, dynamic control and complete shutdown operation of TF power supply.

  14. KLYNAC: Compact linear accelerator with integrated power supply

    Energy Technology Data Exchange (ETDEWEB)

    Malyzhenkov, Alexander [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-16

    Accelerators and accelerator-based light sources have a wide range of applications in science, engineering technology and medicine. Today the scienti c community is working towards improving the quality of the accelerated beam and its parameters while trying to develop technology for reducing accelerator size. This work describes a design of a compact linear accelerator (linac) prototype, resonant Klynac device, which is a combined linear accelerator and its power supply - klystron. The intended purpose of a Klynac device is to provide a compact and inexpensive alternative to a conventional 1 to 6 MeV accelerator, which typically requires a separate RF source, an accelerator itself and all the associated hardware. Because the Klynac is a single structure, it has the potential to be much less sensitive to temperature variations than a system with separate klystron and linac. We start by introducing a simpli ed theoretical model for a Klynac device. We then demonstrate how a prototype is designed step-by-step using particle-in-cell simulation studies for mono- resonant and bi-resonant structures. Finally, we discuss design options from a stability point of view and required input power as well as behavior of competing modes for the actual built device.

  15. Thermal-hydraulics and safety analysis of sectored compact reactor for lunar surface power

    Energy Technology Data Exchange (ETDEWEB)

    Schriener, T. M. [Inst. for Space and Nuclear Power Studies, Univ. of New Mexico, Albuquerque, NM (United States); Chemical and Nuclear Engineering Dept., Univ. of New Mexico, Albuquerque, NM (United States); El-Genk, M. S. [Inst. for Space and Nuclear Power Studies, Univ. of New Mexico, Albuquerque, NM (United States); Chemical and Nuclear Engineering Dept., Univ. of New Mexico, Albuquerque, NM (United States); Mechanical Engineering Dept., Univ. of New Mexico, Albuquerque, NM (United States)

    2012-07-01

    The liquid NaK-cooled, fast-neutron spectrum, Sectored Compact Reactor (SCoRe-N 5) concept has been developed at the Univ. of New Mexico for lunar surface power applications. It is loaded with highly enriched UN fuel pins in a triangular lattice, and nominally operates at exit and inlet coolant temperatures of 850 K and 900 K. This long-life reactor generates up to 1 MWth continuously for {>=} 20 years. To avoid a single point failure in reactor cooling, the core is divided into 6 sectors that are neutronically and thermally coupled, but hydraulically independent. This paper performs a 3-D the thermal-hydraulic analysis of SCoRe--N 5 at nominal operation temperatures and a power level of 1 MWth. In addition, the paper investigates the potential of continuing reactor operation at a lower power in the unlikely event that one sector in the core experiences a loss of coolant (LOC). Redesigning the core with a contiguous steel matrix enhances the cooling of the sector experiencing a LOC. Results show that with a core sector experiencing a LOC, SCORE-N 5 could continue operating safely at a reduced power of 166.6 kWth. (authors)

  16. State-of-the-art piezoelectric transformer-based switch mode power supplies

    DEFF Research Database (Denmark)

    Ekhtiari, Marzieh; Zhang, Zhe; Andersen, Michael A. E.

    2014-01-01

    Inductorless switch mode power supplies based on piezoelectric transformers are used to replace conventional transformers in high power density switch mode power supplies. Even though piezoelectric-based converters exhibit a high d egree of nonlinearity, it is desirable to use piezoelectric transfo...... discusses power supplies with the trend evaluation of piezoelectric transformer-based converter topologies and control methods. The challenges of piezoelectric transformers regarding soft switching capability and nonlinearity are addressed. This paper can be used as a guideline f or choosing a proper...... topology of piezoelectric-based switch mode power supply and a control method for the required application....

  17. Tri-state Modulation Power Driving of Electro-hydraulic Proportional Amplifier

    Institute of Scientific and Technical Information of China (English)

    NIE Yong; WANG Qingfeng

    2009-01-01

    Switch electro-hydraulic proportional amplifier(PA) widely employs single switch modulation power driving(SSMPD) or reverse discharging power driving(RDPD) at present. SSMPD has slow dynamic response, and can't adjust independently the dither signal's amplitude and frequency;RDPD accelerates the current decay;consequently, it increases current ripple and power loss. For the purpose of solving the above mentioned problem, the tri-state modulation power driving(TSMPD) scheme was proposed for improving the performance of power driving. Detailedly, the hardware circuit for the tri-state modulation power driving is designed;the tri-state modulation algorithm is realized by digital signal processor(DSP). The tri-state modulation power driving is investigated by experiments, comparetive experiments among the single switch modulation power driving(SSMPD), reverse discharging power driving(RDPD), and the TSMPD are implemented, and the experimental results demonstrate that the linearity error of TSMDP meets the requirement of PA;the current response of TSMSP is the best;the amplitude of ripple current of the TSMPD can be reduced without increasing frequency of PWM, in addition, dither signal amplitude and frequency can be adjusted independently for each other. It is very meaningful to guide the development of high performance proportional amplifier for high frequency response proportional solenoid.

  18. ICCP cathodic protection of tanks with photovoltaic power supply

    Directory of Open Access Journals (Sweden)

    Janowski Mirosław

    2016-01-01

    Full Text Available Corrosion is the result of the electrochemical reaction between a metal or composite material usually having conducting current properties. Control of corrosion related defect is a very important problem for structural integrity in ground based structures. Cathodic protection (CP is a technique to protect metallic structures against corrosion in an aqueous environment, it is employed intense on the steel drains in oil and gas industry, specifically to protect underground tanks and pipelines. CP is commonly applied to a coated structure to provide corrosion control to areas where the coating may be damaged. It may be applied to existing structures to prolong their life. There are two types of cathodic protection systems: sacrificial (galvanic anode cathodic protection (SACP; the other system is Impressed Current Cathodic Protection (ICCP. Majority of the structures protected employ impressed current system. The main difference between the two is that SACP uses the galvanic anodes which are electrochemically more electronegative than the structure to be protected - the naturally occurring electrochemical potential difference between different metallic elements to provide protection; ICCP uses an external power source (electrical generator with D.C. with inert anodes, and this system is used for larger structures, or where electrolyte resistivity is high and galvanic anodes cannot economically deliver enough current to provide protection. The essential of CP is based on two parameters, the evolution of the potential and the current of protection. A commonly accepted protection criterion used for steel is a potential value of minus 850 mV. ICCP system consist of anodes connected to a DC power source. As power sources may be used such as solar panels, wind turbines, etc. The object of this study is analysis of the possibilities and operating parameters of ICCP system supplied with photovoltaic solar panels. Photovoltaic generator made up of the

  19. 500 Watt Diesel Fueled TPV Portable Power Supply

    Science.gov (United States)

    Horne, W. E.; Morgan, M. D.; Sundaram, V. S.; Butcher, T.

    2003-01-01

    A test-bed 500 watt diesel fueled thermophotovoltaic (TPV) portable power supply is described. The goal of the design is a compact, rugged field portable unit weighing less than 15 pounds without fuel. The conversion efficiency goal is set at 15% fuel energy to electric energy delivered to an external load at 24 volts. A burner/recuperator system has been developed to meet the objectives of high combustion air preheat temperatures with a compact heat exchanger, low excess air operation, and high convective heat transfer rates to the silicon carbide emitter surface. The burner incorporates a air blast atomizer with 100% of the combustion air passing through the nozzle. Designed firing rate of 2900 watts at 0.07 gallons of oil per hour. This incorporates a single air supply dc motor/fan set and avoids the need for a system air compressor. The recuperator consists of three annular, concentric laminar flow passages. Heat from the combustion of the diesel fuel is both radiantly and convectively coupled to the inside wall of a cylindrical silicon carbide emitter. The outer wall of the emitter then radiates blackbody energy at the design temperature of 1400°C. The cylindrical emitter is enclosed in a quartz envelope that separates it from the photovoltaic (PV) cells. Spectral control is accomplished by a resonant mesh IR band-pass filter placed between the emitter and the PV array. The narrow band of energy transmitted by the filter is intercepted and converted to electricity by an array of GaSb PV cells. The array consists of 216 1-cm × 1-cm GaSb cells arranged into series and parallel arrays. An array of heat pipes couple the PV cell arrays to a heat exchanger which is cooled by forced air convection. A brief status of the key TPV technologies is presented followed by data characterizing the performance of the 500 watt TPV system.

  20. Method for reducing excess heat supply experienced in typical Chinese district heating systems by achieving hydraulic balance and improving indoor air temperature control at the building level

    DEFF Research Database (Denmark)

    Zhang, Lipeng; Gudmundsson, Oddgeir; Thorsen, Jan Eric;

    2016-01-01

    that once the hydraulic balance is achieved and indoor temperatures are controlled with this integrated approach, 17% heat savings and 42.8% pump electricity savings can be achieved. The energy savings will also have a positive environmental effect with seasonal reductions of 11 kg CO2, 0.1 kg SO2, and 0...... with the actual heat demand. This results in 15-30% of the total supplied heat being lost. This paper proposes an integrated approach that aims to reduce the excess heat loss by introducing pre-set thermostatic radiator valves combined with automatic balancing valves. Those devices establish hydraulic balance...

  1. Simulation as a key to success in power supply design and development

    Energy Technology Data Exchange (ETDEWEB)

    Suur-Askola, S.; Laasonen, M.; Maeki, J. [Efore Muuntolaite Oy, Vantaa (Finland)

    1997-12-31

    This paper describes the design and development process of a power supply by using simulation methods. The simulation principles and results of a 40W power supply are provided including EMI, voltage and current rating verification as well as power loss approximation. (orig.) 8 refs.

  2. 33 CFR 150.710 - What are the requirements for supplying power to aids to navigation?

    Science.gov (United States)

    2010-07-01

    ... supplying power to aids to navigation? 150.710 Section 150.710 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS Aids to Navigation § 150.710 What are the requirements for supplying power to aids to navigation? The power of all...

  3. 29 CFR 1926.305 - Jacks-lever and ratchet, screw, and hydraulic.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Jacks-lever and ratchet, screw, and hydraulic. 1926.305... Power § 1926.305 Jacks—lever and ratchet, screw, and hydraulic. (a) General requirements. (1) The... secured at once. (ii) Hydraulic jacks exposed to freezing temperatures shall be supplied with an...

  4. Feasibility of a Hydraulic Power Assist System for Use in Hybrid Neuroprostheses

    Directory of Open Access Journals (Sweden)

    Kevin M. Foglyano

    2015-01-01

    Full Text Available Feasibility of using pressurized hydraulic fluid as a source of on-demand assistive power for hybrid neuroprosthesis combining exoskeleton with functional neuromuscular stimulation was explored. Hydraulic systems were selected as an alternative to electric motors for their high torque/mass ratio and ability to be located proximally on the exoskeleton and distribute power distally to assist in moving the joints. The power assist system (PAS was designed and constructed using off-the-shelf components to test the feasibility of using high pressure fluid from an accumulator to provide assistive torque to an exoskeletal hip joint. The PAS was able to provide 21 Nm of assistive torque at an input pressure of 3171 kPa with a response time of 93 ms resulting in 32° of hip flexion in an able-bodied test. The torque output was independent of initial position of the joint and was linearly related to pressure. Thus, accumulator pressure can be specified to provide assistive torque as needed in exoskeletal devices for walking or stair climbing beyond those possible either volitionally or with electrical stimulation alone.

  5. Versatile CAMAC power supply controller-monitor with built-in ramping and ripple monitor

    Energy Technology Data Exchange (ETDEWEB)

    Kang, H.; Horelick, D.

    1984-10-01

    An integrated power supply controller-monitor has been designed and is in use to control large power supplies for SLC dc magnets. This single-width CAMAC module contains a 14-bit DAC, a 14-bit ADC, and several channels of optically coupled digital status and control signals. Additional features include built-in selectable ramping rates, self-test capabilities, and a ripple monitor circuit to measure ac ripple in the power supply current.

  6. Cooling Performance Test of the SCT LV&HV Power Supply Rack

    CERN Document Server

    Böhm, J; Vacek, V

    2005-01-01

    The cooling performance test of the 52U rack, housing SCT LV&HV power supplies for 192 detector modules, being located in USA15 cavern, has been curried out. The rack was equipped with two air-water heat exchangers, air turbine, four vertical fan tray units under crates and horizontal fans in four Artesyn AC/DC power supply units. The resistive dummy loads for 192 power supply channels have been placed in four crates and housed in the adjacent rack.

  7. Investigation of Input Signal Curve Effect on Formed Pulse of Hydraulic-Powered Pulse Machine

    Science.gov (United States)

    Novoseltseva, M. V.; Masson, I. A.; Pashkov, E. N.

    2016-04-01

    Well drilling machines should have as high efficiency factor as it is possible. This work proposes factors that are affected by change of input signal pulse curve. A series of runs are conducted on mathematical model of hydraulic-powered pulse machine. From this experiment, interrelations between input pulse curve and construction parameters are found. Results of conducted experiment are obtained with the help of the mathematical model, which is created in Simulink Matlab. Keywords - mathematical modelling; impact machine; output signal amplitude; input signal curve.

  8. Power supply to the public grid with power plant standard; Netzeinspeisesystem im Kraftwerksstandard

    Energy Technology Data Exchange (ETDEWEB)

    Seltmann, T.

    1999-01-01

    Siemens offers an new current inverter system which supplies solar power from large PV systems to the public grid in master-slave operation. The system is based on current inverter drives which have been used as serial products in industrial applications. [Deutsch] Siemens bietet jetzt ein Wechselrichtersystem an, das im Master-Slave-Betrieb den Solarstrom aus grossen PV-Anlagen ins Netz einspeist. Das System basiert auf Antriebsstromrichtern, die sich bereits als Serienprodukte in der industriellen Anwendung bewaehrt haben. (orig.)

  9. Variants of Secondary Control with Power Recovery for Loading Hydraulic Driving Device

    Institute of Scientific and Technical Information of China (English)

    QI Xiaoye

    2015-01-01

    Current high power load simulators are generally incapable of obtalning both high loading performance and high energy efficiency. Simulators with high energy efficiency are used to simulate static-state load, and those with high dynamic performance typically have low energy efficiency. In this paper, the variants of secondary control (VSC) with power recovery are developed to solve this problem for loading hydraulic driving devices that operate under variable pressure, unlike classical secondary control (CSC) that operates in constant pressure network. Hydrostatic secondary control units are used as the loading components, by which the absorbed mechanical power from the tested device is converted into hydraulic power and then fed back into the tested system through 4 types of feedback passages (FPs). The loading subsystem can operate in constant pressure network, controlled variable pressure network, or the same variable pressure network as that of the tested device by using different FPs. The 4 types of systems are defined, and their key techniques are analyzed, including work principle, simulating the work state of original tested device, static operation points, loading performance, energy efficiency, and control strategy, etc. The important technical merits of the 4 schemes are compared, and 3 of the schemes are selected, designed, simulated using AMESim and evaluated. The researching results show that the investigated systems can simulate the given loads effectively, realize the work conditions of the tested device, and furthermore attaln a high power recovery efficiency that ranges from 0.54 to 0.85, even though the 3 schemes have different loading performances and energy efficiencies. This paper proposes several loading schemes that can achieve both high dynamic performance and high power recovery efficiency.

  10. A Performance Improvement of Power Supply Module for Safety-related Controller

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong-Kyun; Yun, Dong-Hwa; Hwang, Sung-Jae; Lee, Myeong-Kyun; Yoo, Kwan-Woo [PONUTech Co., Seoul (Korea, Republic of)

    2015-10-15

    In this paper, in relation to voltage shortage state when power supply module is a slave mode, the performance improvement by modifying a PFC(Power Factor Correction) circuit is presented. With the modification of the PFC circuit, the performance improvement in respect of the voltage shortage state when the power supply module is a slave mode is checked. As a result, POSAFE-Q PLC can ensure the stability with the redundant power supply module. The purpose of this paper is to improve the redundant performance of power supply module(NSPS-2Q). It is one of components in POSAFE-Q which is a PLC(Programmable Logic Controller) that has been developed for the evaluation of safety-related. Power supply module provides a stable power in order that POSAFE-Q can be operated normally. It is possible to be mounted two power supply modules in POSAFE-Q for a redundant(Master/Slave) function. So that even if a problem occurs in one power supply module, another power supply module will provide a power to POSAFE-Q stably.

  11. Minimization of the transformer inter-winding parasitic capacitance for modular stacking power supply applications

    DEFF Research Database (Denmark)

    Nguyen-Duy, Khiem; Ouyang, Ziwei; Knott, Arnold

    2014-01-01

    In an isolated power supply, the inter-winding parasitic capacitance plays a vital role in the mitigation of common mode noise currents created by fast voltage transient responses. The lower the transformer inter-winding capacitance, the more immune the power supply is to fast voltage transient...... responses. This requirement is even more critical for modular stacking applications in which multiple power supplies are stacked. This paper addresses the issue by presenting a detailed analysis and design of an unconventional isolated power supply that uses a ring core transformer with a very low inter...

  12. Design and Analysis of the Poloidal Field Grid Power Supply System for the HT-7 Tokamak

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    This paper reports a new project - the poloidal field (PF) grid power supply system to replace the ac flywheel generator power supply system on the basis of the present running parameters of the HT-7 poloidal field and the short-circuit capacity of our transformer substation.The designed parameters of the PF grid power supply system have been verified to meet the requirements of the heating field (HF) and the vertical field (VF). In the meantime, in order to reduce the disturbance to the local power grid, the device of reactive power and harmonic current compensation has been added. Experimental results have confirmed the feasibility of the PF grid power supply system. Compared with the ac flywheel generator, the PF grid power supply system has the advantages of lower noise, precise control, convenient maintenance, simple operation and cost savings.

  13. Proposal for the award of a blanket contract for the supply and maintenance of uninterruptable power supplies (UPS)

    CERN Document Server

    2000-01-01

    This document concerns the award of a blanket contract for the supply and maintenance of uninterruptable power supplies (UPS). Following a market survey carried out among 75 firms in eighteen Member States, a call for tenders (IT-2746/ST) was sent on 7 April 2000 to nine firms in four Member States. By the closing date, CERN had received tenders from six firms in four Member States. The Finance Committee is invited to agree to the negotiation of a blanket contract with GUTOR (CH), the lowest bidder after realignment, for the supply and maintenance of uninterruptable power supplies for a total amount of 5 000 000 Swiss francs, not subject to revision until 31 December 2002. The firm has indicated the following distribution by country of the contract value covered by this adjudication proposal: DK?54.3%, CH?23.7%, IT?10%, DE?10%, IE?1% and JP?1%.

  14. Design of A Hydraulic Power Take-off System for the Wave Energy Device with An Inverse Pendulum

    Institute of Scientific and Technical Information of China (English)

    张大海; 李伟; 赵海涛; 鲍经纬; 林勇刚

    2014-01-01

    This paper describes a dual-stroke acting hydraulic power take-off (PTO) system employed in the wave energy converter (WEC) with an inverse pendulum. The hydraulic PTO converts slow irregular reciprocating wave motions to relatively smooth, fast rotation of an electrical generator. The design of the hydraulic PTO system and its control are critical to maximize the generated power. A time domain simulation study and the laboratory experiment of the full-scale beach test are presented. The results of the simulation and laboratory experiments including their comparison at full-scale are also presented, which have validated the rationality of the design and the reliability of some key components of the prototype of the WEC with an inverse pendulum with the dual-stroke acting hydraulic PTO system.

  15. Maximizing MST's inductive capability with a Bp programmable power supply

    Science.gov (United States)

    Chapman, B. E.; Holly, D. J.; Jacobson, C. M.; McCollam, K. J.; Morin, J. C.; Sarff, J. S.; Squitieri, A.

    2016-10-01

    A major goal of the MST program is the advancement of inductive control for the development of both the RFP's fusion potential and, synergistically, the predictive capability of fusion science. This entails programmable power supplies (PPS's) for the Bt and Bp circuits. A Bt PPS is already in place, allowing advanced RFP operation and the production of tokamak plasmas, and a Bp PPS prototype is under construction. To explore some of the new capabilities to be provided by the Bp PPS, the existing Bt PPS has been temporarily connected to the Bp circuit. One key result is new-found access to very low Ip (20 kA) and very low Lundquist number, S (104). At this low S, simulation of RFP plasmas with the MHD code NIMROD is readily achievable, and work toward validation of extended MHD models using NIMROD is underway with direct comparisons to these MST plasmas. The full Bp PPS will also provide higher Ip and S than presently possible, allowing MST to produce plasmas with S spanning as much as five orders of magnitude, a dramatic extension of MST's capability. In these initial tests, the PPS has also increased five-fold MST's Ip flattop duration, to about 100 ms. This, coupled with the recently demonstrated PPS ability to drive large-amplitude sinusoidal oscillations in Ip, will allow tests of extended-duration oscillating field current drive, the goal of which is ac sustainment of a quasi-dc plasma current. Work supported by US DOE.

  16. Development of Heavy-Duty and High-Precision Hydraulic Manipulator for Inspection, Maintenance and Decommission of Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sung Uk; Seo, Yong-chil; Jung, Kyung Min; Kim, Chang-hoi; Choi, Byung-seon; Moon, Jei-kwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Robotic manipulators have been used for inspection, maintenance and decommission of nuclear power plants because nuclear power plants have high radiation and human workers cannot easily access the plants. And also, to inspecting, maintaining and decommissioning nuclear power plants require various manipulators. Only one manipulator cannot response to many required tasks. The existing manipulators that was used at nuclear power plants can only operate only focused specific task and cannot be used at several tasks. The actuators used at manipulators are varied and many companies sell actuators depending on power, torque and speed. However, the commercial product is not standardized. Therefore, the development of manipulator is time consuming and expensive. The essential item of a manipulator is an actuator module. If actuator module is standardized, it’s easier to develop a manipulator and also maintain a manipulator. Recently, manipulator having high-radiation, high-duty and high-precision is necessary to inspection, maintain and decommissioning of nuclear power plants. Hydraulic actuator has been used to development high-duty manipulator. But control performance of a hydraulic actuator is not better than that of an electric actuator so that hydraulic manipulator cannot easily satisfy the required precision. In this paper, we developed high-duty and high-precision actuator modules and hydraulic manipulator using the developed actuator modules. The developed hydraulic manipulator have a payload of 250kg and a precision of ±1mm. Four modularized hydraulic actuator modules were developed for inspection, maintenance and decommission. Using the developed actuator modules, the manipulator for decommissioning is easily developed. And also, various manipulators having different kinematic structure for specific tasks will be easily developed by using hydraulic modules.

  17. Shock Mechanism Analysis and Simulation of High-Power Hydraulic Shock Wave Simulator

    Directory of Open Access Journals (Sweden)

    Xiaoqiu Xu

    2017-01-01

    Full Text Available The simulation of regular shock wave (e.g., half-sine can be achieved by the traditional rubber shock simulator, but the practical high-power shock wave characterized by steep prepeak and gentle postpeak is hard to be realized by the same. To tackle this disadvantage, a novel high-power hydraulic shock wave simulator based on the live firing muzzle shock principle was proposed in the current work. The influence of the typical shock characteristic parameters on the shock force wave was investigated via both theoretical deduction and software simulation. According to the obtained data compared with the results, in fact, it can be concluded that the developed hydraulic shock wave simulator can be applied to simulate the real condition of the shocking system. Further, the similarity evaluation of shock wave simulation was achieved based on the curvature distance, and the results stated that the simulation method was reasonable and the structural optimization based on software simulation is also beneficial to the increase of efficiency. Finally, the combination of theoretical analysis and simulation for the development of artillery recoil tester is a comprehensive approach in the design and structure optimization of the recoil system.

  18. Dynamic Analysis and Design Optimization of Series Hydraulic Hybrid System through Power Bond Graph Approach

    Directory of Open Access Journals (Sweden)

    R. Ramakrishnan

    2014-01-01

    Full Text Available The availability of natural gas and crude oil resources has been declining over the years. In automobile sector, the consumption of crude oil is 63% of total crude oil production in the world. Hence, automobile industries are placing more emphasis on energy efficient hydraulic hybrid systems, which can replace their conventional transmission systems. Series hydraulic hybrid system (SHHS is a multidomain mechatronics system with two distinct power sources that includes prime mover and hydropneumatic accumulator. It replaces the conventional transmission system to drive the vehicle. The sizing of the subsystems in SHHS plays a major role in improving the energy efficiency of the vehicle. In this paper, a power bond graph approach is used to model the dynamics of the SHHS. The obtained simulation results indicate the energy flow during various modes of operations. It also includes the dynamic response of hydropneumatic accumulator, prime mover, and system output speed. Further, design optimization of the system is carried out to optimize the process parameters for maximizing the system energy efficiency. This leads to increase in fuel economy and environmentally friendly vehicle.

  19. ASCERTAINMENT OF ELECTRIC-SUPPLY SCHEMES RELIABILITY FOR THE ATOMIC POWER PLANT AUXILIARIES

    Directory of Open Access Journals (Sweden)

    A. L. Starzhinskij

    2015-01-01

    Full Text Available The paper completes ascertainment of electrical-supply scheme reliability for the auxiliaries of a nuclear power plant. Thereat the author considers the system behavior during the block normal operation, carrying out current maintenance, and capital repairs in combination with initiating events. The initiating events for reactors include complete blackout, i.e. the loss of outside power supply (normal and reserve; emergency switching one of the working turbogenerators; momentary dumping the normal rating to the level of auxiliaries with seating the cutout valve of one turbo-generator. The combination of any initiating event with the repairing mode in case of one of the system elements failure should not lead to blackout occurrence of more than one system of the reliable power supply. This requirement rests content with the help of the reliable power supply system self-dependence (electrical and functional and the emergency power-supply operational autonomy (diesel generator and accumulator batteries.The reliability indicators of the power supply system for the nuclear power plant auxiliaries are the conditional probabilities of conjoined blackout of one, two, and three sections of the reliable power supply conditional upon an initiating event emerging and the blackout of one, two, and three reliable power-supply sections under the normal operational mode. Furthermore, they also are the blackout periodicity of one and conjointly two, three, and four sections of normal operation under the block normal operational mode. It is established that the blackout of one bus section of normal operation and one section of reliable power-supply system of the auxiliaries that does not lead to complete blackout of the plant auxiliaries may occur once in three years. The probability of simultaneous power failure of two or three normal-operation sections and of two reliable power-supply sections during the power plant service life is unlikely.

  20. Supplying the Power Requirements to a Sensor Network Using Radio Frequency Power Transfer

    Directory of Open Access Journals (Sweden)

    Steven Percy

    2012-06-01

    Full Text Available Wireless power transmission is a method of supplying power to small electronic devices when there is no wired connection. One way to increase the range of these systems is to use a directional transmitting antenna, the problem with this approach is that power can only be transmitted through a narrow beam and directly forward, requiring the transmitter to always be aligned with the sensor node position. The work outlined in this article describes the design and testing of an autonomous radio frequency power transfer system that is capable of rotating the base transmitter to track the position of sensor nodes and transferring power to that sensor node. The system’s base station monitors the node’s energy levels and forms a charge queue to plan charging order and maintain energy levels of the nodes. Results show a radio frequency harvesting circuit with a measured S11 value of −31.5 dB and a conversion efficiency of 39.1%. Simulation and experimentation verified the level of power transfer and efficiency. The results of this work show a small network of three nodes with different storage types powered by a central base node.

  1. 76 FR 57897 - Energy Conservation Program: Energy Conservation Standards for Certain External Power Supplies

    Science.gov (United States)

    2011-09-19

    ... RIN 1904-AB57 Energy Conservation Program: Energy Conservation Standards for Certain External Power... exclude external power supplies used in specific applications from certain energy conservation standards prescribed under the Energy Policy and Conservation Act (EPCA). Congress enacted this exclusion,...

  2. Thermal-hydraulic tests of a recirculation cooling installation for the Rostov nuclear power station

    Science.gov (United States)

    Balunov, B. F.; Balashov, V. A.; Il'in, V. A.; Krayushnikov, V. V.; Lychakov, V. D.; Meshalkin, V. V.; Ustinov, A. N.; Shcheglov, A. A.

    2013-09-01

    Results obtained from thermal-hydraulic tests of the recirculation cooling installation used as part of the air cooling system under the containments of the Rostov nuclear power station Units 3 and 4 are presented. The operating modes of the installation during normal operation (air cooling on the surface of finned tubes), under the conditions of anticipated operational occurrences (air cooling and steam condensation from a steam-air mixture), and during an accident (condensation of pure steam) are considered. Agreement is obtained between the results of tests and calculations carried out according to the recommendations given in the relevant regulatory documents. A procedure of carrying out thermal calculation for the case of steam condensation from a steam-air mixture on the surface of fins is proposed. The possibility of efficient use of the recirculation cooling installation in the system for reducing emergency pressure under the containment of a nuclear power station is demonstrated.

  3. Wind-powered asynchronous AC/DC/AC converter system. [for electric power supply regulation

    Science.gov (United States)

    Reitan, D. K.

    1973-01-01

    Two asynchronous ac/dc/ac systems are modelled that utilize wind power to drive a variable or constant hertz alternator. The first system employs a high power 60-hertz inverter tie to the large backup supply of the power company to either supplement them from wind energy, storage, or from a combination of both at a preset desired current; rectifier and inverter are identical and operate in either mode depending on the silicon control rectifier firing angle. The second system employs the same rectification but from a 60-hertz alternator arrangement; it provides mainly dc output, some sinusoidal 60-hertz from the wind bus and some high harmonic content 60-hertz from an 800-watt inverter.

  4. Novel Radio on Fiber Access Eliminating External Electric Power Supply at Base Station

    Institute of Scientific and Technical Information of China (English)

    Tetsuya; Miki; Katsuyasu; Kawano; Nobuo; Nakajima; Naoto; Kishi; Masaru; Miyamoto; Tetsu; Aoki

    2003-01-01

    A novel Radio On Fiber(ROF) access is proposed and demonstrated which enables the pico-cell Base Station (BS) for high-speed wireless communications to eliminate external electric power supply facilities. We demonstrated 2.4-GHz band radio signal transmission through the BS without external electric power supply. The electrical power used for BS circuit is feeded by optical power over optical fiber from central station.

  5. Application of EPANET Hydraulic Model on Water Supply in Some Place%EPANET水力模型在片区供水中的运用

    Institute of Scientific and Technical Information of China (English)

    俞曼; 陈越舫

    2011-01-01

    Software of EPANET hydraulic model was applied to simulate the operational status of network on water supply which combine practical engineering in Kunming. It proposes the program on the pipe network of water diversion to meet the pressure requirement. It provides scientific basis for program on laying of network on water supply.%结合昆明实际工程,应用EPANFT水力模型软件,模拟供水管网的运行状况.提出满足水压要求的管网调水方案,为供水管网的敷设方案提供科学依据.

  6. Design of the dummy coil for magnet power supply

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang-Hwan, E-mail: kch2004@nfri.re.kr; Choi, Jae-Hoon; Jin, Jong-Kook; Lee, Dong-Keun; Kong, Jong-Dea; Joung, Nam-Young; Kim, Sang-Tae; Kim, Young-Jin; Kim, Yang-Soo; Kwon, Myeun

    2013-11-15

    Highlights: • It is necessary to confirm safety of the MPS on a dummy coil before the operating it. • We selected and designed the water cooling type dummy coil to test on the MPS's rating (12.5 kA) test. • For the design of the dummy coil, we considered requirements about electrical, structural and water cooling. • We will test as the rating power after MPS upgrade and that test will do before every KSTAR campaign. -- Abstract: It is necessary to test it on a dummy coil, before using a magnet power supply (MPS) to energize a Poloidal Field (PF) coil in the Korea Superconducting Tokamak Advanced Research (KSTAR) device. The dummy coil should accept the same large current from the MPS as the PF coil and be within the capability of the utilities located at the KSTAR site. Therefore a coil design based on the characteristics of the MPS and other restrictive conditions needed to be made. There are three requirements to be met in the design: an electrical requirement, a structural requirement, and a water cooling requirement. The electrical requirement was that the coil should have an inductance of 40 mH. For the structural requirement, the material should be non magnetic. The coil support structure and water cooling manifold were made of SUS 304. The water cooling requirement was that there should be sufficient flow rate so that the temperature rise ΔT should not exceed 12 °C for operation at 12.5 kA for 5 min. Square cross-section hollow conductor with dimensions of 38.1 mm × 38.1 mm was used with a 25.4 mm center hole for cooling water. However, as a result of tests, it was found that the electrical and structural requirements were satisfied but that the water cooling was over designed. It is imperative that the verification will be redone for a test with 12.5 kA for 5 min.

  7. 47 CFR 15.102 - CPU boards and power supplies used in personal computers.

    Science.gov (United States)

    2010-10-01

    ... computers. 15.102 Section 15.102 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES Unintentional Radiators § 15.102 CPU boards and power supplies used in personal computers. (a... modifications that must be made to a personal computer, peripheral device, CPU board or power supply during...

  8. New 50 Hz Superconducting Power Supply for a 2 kA DC Magnet

    NARCIS (Netherlands)

    Chevtchenko, O.A.; ten Kate, Herman H.J.; Krooshoop, Hendrikus J.G.

    1994-01-01

    A new superconducting power supply able to operate directly from the mains voltage at a frequency of 50-60 Hz is under development in our institutes. It will be applied to power a separator magnet for iron ore recycling. The supply consists of a full wave superconducting converter, a `cold'

  9. Loss Performance Analysis of an Isolated Power Supply for Ultrafast Tracking Converters

    DEFF Research Database (Denmark)

    Nguyen-Duy, Khiem; Knott, Arnold; Andersen, Michael A. E.

    2014-01-01

    This paper presents the loss performance analysis of an isolated power supply that is designed for ultra-fast tracking converters. The results of the analysis provide insights into the operation of the proposed power supply, how each physical component contributes to the total loss, and how its e...

  10. 14 CFR 125.377 - Fuel supply: Turbine-engine-powered airplanes other than turbopropeller.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Fuel supply: Turbine-engine-powered... AIRCRAFT Flight Release Rules § 125.377 Fuel supply: Turbine-engine-powered airplanes other than... wind and other weather conditions expected, it has enough fuel— (1) To fly to and land at the...

  11. 77 FR 22472 - Energy Conservation Program: Energy Conservation Standards for Certain External Power Supplies...

    Science.gov (United States)

    2012-04-16

    ... Part 430 RIN 1904-AB57 Energy Conservation Program: Energy Conservation Standards for Certain External... energy conservation standards for certain external power supplies to re-insert a table that had been... statutorily-prescribed energy conservation standards for all Class A external power supplies to meet....

  12. 47 CFR 15.32 - Test procedures for CPU boards and computer power supplies.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Test procedures for CPU boards and computer... FREQUENCY DEVICES General § 15.32 Test procedures for CPU boards and computer power supplies. Power supplies and CPU boards used with personal computers and for which separate authorizations are required to be...

  13. Thermal control of power supplies with electronic packaging techniques. [using low cost heat pipes

    Science.gov (United States)

    1977-01-01

    The integration of low-cost commercial heat pipes in the design of a NASA candidate standard modular power supply with a 350 watt output resulted in a 44% weight reduction. Part temperatures were also appreciably reduced, increasing the environmental capability of the unit. A complete 350- watt modular power converter was built and tested to evaluate thermal performance of the redesigned supply.

  14. Higher Power Supply Reliability of Agro-Industrial Complex (AIC Consumers

    Directory of Open Access Journals (Sweden)

    V. I. Rusan

    2009-01-01

    Full Text Available The paper presents the developed methodology that has been used for making calculations of main reliability indices for existing electric power supply circuits of AIC consumers. Some measures pertaining to provision of higher reliability are given in the paper. The paper contains calculations of changes in respect of reliability indices and reduction in cost of supply lost due to power supply interruptions in case of introduction of the proposed  measures.

  15. The power supply system model of the process submersible device with AC power transmission over the cable-rope

    Science.gov (United States)

    Rulevskiy, V. M.; Bukreev, V. G.; Kuleshova, E. O.; Shandarova, E. B.; Shandarov, S. M.; Vasilyeva, Yu Z.

    2017-02-01

    A practical problem of power supply system modeling for the process submersible device with AC power transmission over the cable-rope was considered. The problem is highly relevant in developing and operation of submersible centrifugal pumps and submersibles. The results of modeling a symmetrical three-phase power supply system and their compliance with the real data are given at the paper. The obtained results in the mathematical and simulation models were similar.

  16. Proposal for the Award of a Contract for the Supply 1000 Quench Heater Power Supplies for the LHC

    CERN Document Server

    2003-01-01

    This document concerns the award of a contract for the supply of 1000 quench heater power supplies for the LHC. Following a market survey carried out among 84 firms in fifteen Member States, a call for tenders (IT-3167/AB/LHC) was sent on 18 February 2003 to 10 firms in eight Member States. By the closing date, CERN had received 10 tenders from the 10 firms in eight Member States. The Finance Committee is invited to agree to the negotiation of a contract with EFACEC (PT), the lowest bidder, for the supply of 1000 quench heater power supplies for a total amount of 704 113 euros (1 042 018 Swiss francs), not subject to revision, with an option for additional purchases of up to 1000 quench heater power supplies, for an additional maximum amount of 704 113 euros (1 042 018 Swiss francs), not subject to revision, bringing the total amount to 1 408 226 euros (2 084 036 Swiss francs). The rate of exchange used is that stipulated in the tender. The firm has indicated the following distribution by country of the contr...

  17. The NC Power Supply Design of Large Current and Wide Frequency Pulse in SEAM

    Directory of Open Access Journals (Sweden)

    Jianping Zhou

    2013-07-01

    Full Text Available There are a lot of ways to achieve large current pulse power supply, and the more common way is to adopt the inverter switching circuit to achieve pulse power supply. The core of the NC power supply design of large current and wide frequency pulse in SEAM is using two-stage modulation. Combined with inverter technology, DC chopper technology and NC technology, it not only can achieve the adjustability of the output pulse amplitude, but also can realize continuous adjustment of the output pulses and the duty cycle. The front stage of power supply uses DC/DC transformation circuit with the UC3879 integrated control chip as the core. With the microcontroller as the control core, the backward stage uses DC chopper circuit to achieve the NC power supply of multi-parameter adjustable output large current pulse.

  18. Regional power supply with decentral and renewable energy sources; Regionale Energieversorgung mit dezentralen und erneuerbaren Energien

    Energy Technology Data Exchange (ETDEWEB)

    Bonow, Martin [Genossenschaftsverband, Neu-Isenburg/Zeppelinheim-Ost (Germany); George, Wolfgang [GenoPortal, Neu-Isenburg (Germany); Klement, Martin [Kassel Univ. (Germany). Fachbereich 6 - Architektur, Stadtplanung, Landschaftsplanung

    2009-04-15

    The contribution starts by assuming a region as a business organisation; on this basis, the authors develop the idea of a regional value-adding chain with regard to regional power supply. After presenting the central actors and their manner of integration, the contribution discusses concepts for sustainable power supply as well as the central parameters of such a development in terms of quality of life, attractivity of the region, future success of technologies, and criteria of value-adding. Finally, the implementation of regional power supply with the aid of a so-called 'balanced scorecard' is explained, which involves balancing of the various perspectives of the process up to the establishment of the final regional power supply concept. Finally, the contribution briefly discusses co-operative models for the establishment of a regional power supply concept. (orig.)

  19. High efficiency fuel cell based uninterruptible power supply for digital equipment

    Science.gov (United States)

    Gonzales, James; Tamizhmani, Govindasamy

    Eliminating the ac-dc converter (such as a computer's power supply), in a dc system when using a fuel cell based uninterruptible power supply (UPS), serves several primary functions. Firstly, it eliminates the need for a dc-ac inverter, and secondly, it eliminates a usually highly inefficient component-the power supply. Multiple conversions result in multiple inefficiencies. By replacing the computer's ac power supply with a high efficiency dc power supply capable of operating directly from a fuel cell - and thereby eliminating the inverter - the overall efficiency of the UPS can be increased by 50% or more. This is essential considering that the primary function of a fuel cell based UPS is long-term operation of the system, and poor efficiency equates to higher fuel consumption. Furthermore, inefficient systems have greater power demands, and therefore a larger fuel cell stack is needed to power them. At the present cost of fuel cell systems, this is a considerable problem. The easiest way to accomplish a direct dc UPS is to replace the computer's ac-dc power supply with a dc-dc power supply.

  20. Technogeopologistics: Supply Networks and Military Power in the Industrial Age

    Science.gov (United States)

    2012-06-01

    the German Western campaign were fully motorized .48 As a result, the vast majority of the German infantry marched into battle, supplied with horse...Germans simply had overextended their LOCs.51 In other words, the fast-moving German motorized divisions were in danger of outrunning their logistics...Creveld, Supplying War Hitler had a fascination with cars. The National Socialist movement highlighted the new Autobahn and the Volkswagen as

  1. A new complete model of switch-mode plasma cutting power supply

    Institute of Scientific and Technical Information of China (English)

    Abdolreza Esmaeli; SUN Li(孙力); NIE Jian-hong(聂剑红)

    2004-01-01

    A complete model of switch-mode plasma cutting power supply and its simulation are developed. The full bridge isolated pulse width modulation (PWM) buck converter in continuous conduction mode (CCM) for high watt plasma power supply is approached. Reduced ripple current and improved power factor are achieved in the plasma power supply. With a PID control strategy, circuit responses become more stable and faster with low overshoot during load and current changing. The converter achieved high efficiency under 3 to 15kW load conditions.

  2. An Application of Six Sigma for Improving the Efficiency of Power Supply

    Directory of Open Access Journals (Sweden)

    Chang-Hsien Hsu

    2013-10-01

    Full Text Available Implementing the Six Sigma control method is to use define, measure, analyze, improve and control (DMAIC framework to improve the process from the beginning, emphasize the process management, reduce the process time, eliminate the defects, and increase the passing rate. The aims of this study is to apply Six Sigma control method with DMAIC framework to shorten the power supply over time in order to enhance the power supply efficiency in T. power company (TPC. The result showed that the power supply over time was reduced from 66% to 30% in the Construction Work Second Section.

  3. Design and Implement of Low Ripple and Quasi-digital Power Supply

    Science.gov (United States)

    Xiangli, Li; Yanjun, Wei; Hanhong, Qi; Yan, Ma

    A switch linearity hybrid power supply based on single chip microcomputer is designed which merged the merits of the switching and linear power supply. Main circuit includes pre-regulator which works in switching mode and series regulator which works in linear mode. Two-stage regulation mode was adopted in the main circuit of the power. A single chip computer (SCM) and high resolution of series D/A and A/D converters are applied to control and measurement which achieved continuous adjustable and low ripple constant current or voltage power supply

  4. THE THERMAL-HYDRAULICS ANALYSIS ON RADIAL AND AXIAL POWER FLUCTUATION FOR AP1000 REACTOR

    Directory of Open Access Journals (Sweden)

    Muh. Darwis Isnaini

    2015-06-01

    Full Text Available ABSTRACT THE THERMAL-HYDRAULICS ANALYSIS ON RADIAL AND AXIAL POWER FLUCTUATION FOR AP1000 REACTOR. The reduction of fissile material during reactor operation affects reactivity reduction. Therefore, in order to keep the reactor operating at fixed power, it must be compensated by slowly withdrawing the control-rod up. However, it will change the shape of the horizontal/axial power distribution and safety margin as well. The research carries out the calculations of the core thermal-hydraulics to determine the effect of the fluctuations of the power distribution on the thermal-hydraulic AP1000’s parameters and study their impacts on the safety margin. The calculation is done using the COBRA-EN code and the result shows that the maximum heat flux at the Beginning of Cycle (BOC is 1624.02 kW/m2. This heat flux will then decrease by 22.75% at the Middle of Cycle (MOC and by 0.29% at the End of Cycle (EOC. The peak fuel centerline temperature at the BOC, MOC and EOC, are 1608.15°C, 1232.15°C, and 1301.75°C, respectively. These temperature differences are caused by the heat flux effects on sub-cooled boiling regions in the cladding surface. Moreover, the value of MDNBRs at the MOC and EOC are 3.23 and 3.00, which are higher than the MDNBR at the BOC of 2.49. It could be concluded that the operating cycle of the AP1000 reactor should be operated in the MOC and the EOC, which will be more safely than be operated in the BOC. Keywords: Core thermal-hydraulics, AP1000, fluctuation of power distribution, COBRA-EN.   ABSTRAK ANALISIS TERMOHIDRAULIKA PADA FLUKTUASI DAYA AXIAL DAN RADIAL UNTUK REAKTOR AP1000. Berkurangnya material fisil selama operasi reaktor, mengakibatkan reaktivitas berkurang. Oleh karena itu, agar reaktor tetap beroperasi pada daya yang tetap, maka harus dikompensasi dengan menarik batang kendali ke atas sedikit demi sedikit. Akan tetapi, hal ini akan berakibat pada berubahnya bentuk distribusi daya ke arah horisontal/aksial dan

  5. Dynamic Power Management for Portable Hybrid Power-Supply Systems Utilizing Approximate Dynamic Programming

    Directory of Open Access Journals (Sweden)

    Jooyoung Park

    2015-05-01

    Full Text Available Recently, the optimization of power flows in portable hybrid power-supply systems (HPSSs has become an important issue with the advent of a variety of mobile systems and hybrid energy technologies. In this paper, a control strategy is considered for dynamically managing power flows in portable HPSSs employing batteries and supercapacitors. Our dynamic power management strategy utilizes the concept of approximate dynamic programming (ADP. ADP methods are important tools in the fields of stochastic control and machine learning, and the utilization of these tools for practical engineering problems is now an active and promising research field. We propose an ADP-based procedure based on optimization under constraints including the iterated Bellman inequalities, which can be solved by convex optimization carried out offline, to find the optimal power management rules for portable HPSSs. The effectiveness of the proposed procedure is tested through dynamic simulations for smartphone workload scenarios, and simulation results show that the proposed strategy can successfully cope with uncertain workload demands.

  6. Transient Processes in Electric Power Supply System for Oil Terminal with Own Gas-Turbine Power Station

    Directory of Open Access Journals (Sweden)

    A. M. Hаshimov

    2009-01-01

    Full Text Available The paper contains results of the investigations concerning influence of symmetrical and non-symmetrical short circuits at main power network on electric power supply system of a huge oil terminal which is powered by own gas-turbine power station. Calculations have been made in accordance with the IEC and IEEЕ requirements. Estimations for voltage level and distribution of short circuit current in the electric power supply system of the Sangachal oil terminal being operated in parallel with the AzerEnerji grid are presented in the paper

  7. Development of hydraulic brake actuator for active brake control; Active brake seigyoyo yuatsu booster no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Konishi, Y.; Hattori, M. Sugisawa, M.; Nishii, M. [Aisin Seiki Co. Ltd., Aichi (Japan)

    1997-10-01

    Recently, application of active brake control systems of the vehicle are increasing. (Vehicle stability control, Panic brake assist ) We have developed a new hydraulic brake actuator for active brake control systems. New hydraulic brake actuator is composed of the three parts. (Hydraulic booster unit, Power supply unit, Control valve unit) This report describes the construction of the new hydraulic booster unit. 2 refs., 10 figs.

  8. Hydraulic Equalizing Valve with Total Power Control%液压泵总功率控制的均压阀

    Institute of Scientific and Technical Information of China (English)

    杨莽; 王林

    2016-01-01

    The design and practical use of the hydraulic system, the two variable piston pump together in the same hydraulic system and to ensure consistency and to achieve the two hydraulic displacement of the total power control. The general use of two cross-pump control mode, the disadvantage is that the two hydraulic control cross consistency and total power control is poor, and it is difficult to ensure the con-sistency of the two hydraulic pumps. In this paper, by designing a pressure equalization valve to achieve the two hydraulic control. The re-sults showed that the equalizing valve can well ensure the consistency of the two hydraulic pumps and total power control.%在液压系统的设计和实际使用过程中,两台变量柱塞液压泵共同作用于同一液压系统并保证两台液压泵排量一致且要实现总功率控制.目前一般采用两台液压泵交叉控制的方式,交叉控制的缺点是两台液压泵的一致性和总功率控制效果差,且很难保证两台液压泵的一致性.该文通过设计一种均压阀,来实现两台液压泵的控制.结果表明,均压阀能够很好地保证两台液压泵的一致性和总功率控制.

  9. The Hydraulic Mission and the Mexican Hydrocracy: Regulating and Reforming the Flows of Water and Power

    NARCIS (Netherlands)

    Wester, P.; Rap, E.R.; Vargas-Velázquez, S.

    2009-01-01

    In Mexico, the hydraulic mission, the centralisation of water control, and the growth of the federal hydraulic bureaucracy (hydrocracy) recursively shaped and reinforced each other during the 20th century. The hydraulic mission entails that the state, embodied in an autonomous hydrocracy, takes the

  10. A preliminary investigation of the Topaz II reactor as a lunar surface power supply

    Energy Technology Data Exchange (ETDEWEB)

    Polansky, G.F. [Sandia National Labs., Albuquerque, NM (United States); Houts, M.G. [Los Alamos National Lab., NM (United States)

    1995-12-31

    Reactor power supplies offer many attractive characteristics for lunar surface applications. The Topaz II reactor resulted from an extensive development program in the former Soviet Union. Flight quality reactor units remain from this program and are currently under evaluation in the United States. This paper examines the potential for applying the Topaz II, originally developed to provide spacecraft power, as a lunar surface power supply.

  11. Electric power supply and demand for the contiguous United States, 1980-1989

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-06-01

    A limited review is presented of the outlook for the electric power supply and demand during the period 1980 to 1989. Only the adequacy and reliability aspects of bulk electric power supply in the contiguous US are considered. The economic, financial and environmental aspects of electric power system planning and the distribution of electricity (below the transmission level) are topics of prime importance, but they are outside the scope of this report.

  12. To Question оf Using Power Reserve оf Power-and-Heat Supply Turbine Plants

    Directory of Open Access Journals (Sweden)

    S. A. Kachan

    2008-01-01

    Full Text Available The paper considers possibilities and limitations of various methods for obtaining power re-serve at power-and-heat supply turbo-generator sets.Approximate values of specific heat rate and quantity of reserve power and rate of its obtaining for various turbine plants are given in the paper.

  13. Mathematical model for the power supply system of an autonomous object with an AC power transmission over a cable rope

    Science.gov (United States)

    Rulevskiy, V. M.; Bukreev, V. G.; Shandarova, E. B.; Kuleshova, E. O.; Shandarov, S. M.; Vasilyeva, Yu Z.

    2017-02-01

    A modeling problem of the power system, which provides an AC power transmission to a submersible device over the conducting rope, was considered. The power supply system units and their parameters are described. The system multi-dimensional mathematical model in the variables state space with regard to the nonlinear characteristic of system elements is proposed.

  14. Method of Sum of Power Losses as a Way for Determining the ki Coefficients of Energy Losses in Hydraulic Motor

    Directory of Open Access Journals (Sweden)

    Maczyszyn A.

    2016-04-01

    Full Text Available This paper shows application of the method of sum of power losses to determining energy losses which occur in hydraulic rotary motor in situation when not all laboratory data are at one’s disposal or when no use is made of data contained in catalogue charts. The method makes it possible to determine the coefficients, ki, of energy losses occurring in the motor. The method of sum of power losses is based on the approach proposed by Z. Paszota, in the papers [3 ÷ 9]. It consists in adding power flow of energy losses occurring in the motor to power flow output and comparing the sum to the power flow input. Application of the method is exemplified by using a A6VM hydraulic motor.

  15. Composite Energy Storage System with Photovoltaic Power Generation and Uninterruptible Power Supply Function

    Directory of Open Access Journals (Sweden)

    Jung-Min Kwon

    2013-01-01

    Full Text Available A composite energy storage system (CESS that includes a photovoltaic (PV power generation and an uninterruptible power supply (UPS function is proposed. This system has three operating modes, namely, a grid-connected inverter mode, a grid-connected rectifier mode, and an islanding mode. This system is composed of a boost converter, a three-phase inverter/rectifier, a bidirectional DC/DC converter, and thyristor switches. The boost converter extracts maximum power from the PV panels and sends it to the DC-link. The bidirectional DC/DC converter is connected between the battery and the DC-link, which leads to an optimized charging/discharging operation. The three-phase inverter/rectifier transmits the power to and from the grid. Also, it operates as a UPS in the islanding mode. The thyristor switches are used for connecting/disconnecting between the grid and the AC load. A 15 kW prototype is implemented to verify the performance of the proposed system.

  16. Prognostics-Enabled Power Supply for ADAPT Testbed Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Ridgetop's role is to develop electronic prognostics for sensing power systems in support of NASA/Ames ADAPT testbed. The prognostic enabled power systems from...

  17. Distributed Control of the Power Supply-Demand Balance

    NARCIS (Netherlands)

    Larsen, Gunn K. H.; van Foreest, Nicky D.; Scherpen, Jacquelien M. A.

    2013-01-01

    This paper aims to achieve a balance of power in a group of prosumers, based on a price mechanism, i.e., to steer the difference between the total production and consumption of power to zero. We first set the information network topology such that the prosumers exchange price (power) information wit

  18. Power Supply for a Manned International Asteroid Mission

    Science.gov (United States)

    Weingartner, Stefan; Nahra, Henry K.; Kohout, Lisa L.; Larin, Max

    1991-01-01

    A feasibility study considering the exploitation of a near Earth asteroid was performed. The power requirements and proposed power systems for the crew vehicle, cargo vehicles, mining and processing equipment are described. A photovoltaic power system was selected to meet the 52.1 kWe and the 3.9 kWe power requirements of the crew and cargo vehicles, respectively. A nuclear power plant using a thermodynamic Rankine cycle with a total mass of 62.1 tons was chosen to provide the 7.225 MWe and the 5.5 MWth required for the mining and processing activities at the asteroid.

  19. Simulation and optimization of wind and diesel power supply systems

    Science.gov (United States)

    Lukutin, B. V.; Shandarova, E. B.; Matukhin, D. L.; Igisenov, A. A.; Shandarov, S. M.

    2017-02-01

    The paper proposes an algorithm to optimize the structure and the choice of capacity of wind and diesel power units of the combined power plant, depending on the wind energy potential and electricity consumption of electrified facility. The algorithm is based on mathematical models of technical and economic characteristics of wind and diesel power plants as well as an optimization method of coordinate descent. The algorithm takes into account the structure of the combined power plant, changing modes of its operation, construction and operation costs of the power facility. The objective function of the algorithm is to minimize the cost of electricity generated.

  20. DEVELOPMENT OF HIGH-VOLTAGE HIGH-FREQUENCY POWER SUPPLY FOR OZONE GENERATION

    Directory of Open Access Journals (Sweden)

    NACERA HAMMADI

    2016-05-01

    Full Text Available A high-voltage high-frequency power supply for ozone generation is presented in this paper. Ozone generation is intended to be used in air and in water disinfection. A power stage consisting of a single-phase full bridge inverter for regulating the output power, a current push-pull inverter (driver and a control circuit are described and analyzed. This laboratory build power supply using a high voltage ferrite transformer and a PIC microcontroller was employed to energize a dielectric barrier discharge (DBD ozone generator. The inverter working on the basis of control strategy is of simple structure and has a variation range of the working frequency in order to obtain the optimal frequency value. The experimental results concerning electrical characterization and water treatment using a cylindrical DBD ozone generator supplied by this power supply are given in the end.

  1. Design of the power supply system for the plasma current modulation on J-TEXT tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, M.; Shao, J.; Ma, S.X., E-mail: mashaoxiang@hust.edu.cn; Liang, X.; Yu, K.X.; Pan, Y.

    2016-10-15

    Highlights: • A modification scheme of heating field power supply system for plasma current modulation. • High-power fast control power supply with multilevel cascade circuit. • Restraining circulating current with coupled inductors in cyclic symmetric structure. - Abstract: In order to further study the influence of current modulation parameters on suppressing tearing instability, the plasma current should be modulated in a wider range. So a modification scheme is designed to improve the performance of ohmic heating power supply system on J-TEXT tokamak. A multilevel cascade circuit with carrier phase-shifted PWM technique has been proposed. Coupled inductors are connected in the form of cyclic symmetry to restrain the circulating current caused by multiple paralleled branches. The simulation proves this proposed current modulation power supply system matches output requirement and achieves good current sharing effect. Finally, a prototype is designed, and the experiment results can verify the correctness of the simulation model well.

  2. Trading Relationship Performance and Market Power in Food Supply Chains

    DEFF Research Database (Denmark)

    Xhoxhi, Orjon

    that contribute to the exercise by intermediaries of these power dimensions. In the third paper a Structural Equation Modelling is employed to analyse the effects of intermediaries’ power on trading relationship performance between farmer and intermediaries. The analysis show that intermediaries’ exercise...... of power over farmers’ margin, leads to reduced relationship performance. On the other hand, when they exercise their power over farmers input selection activities or over harvesting and delivery activities the performance is improved. Furthermore, the result show that intermediaries’ power affects......The development of the agri-food industry has led to a considerable increase of intermediaries’ market power vis-à-vis farmers. There are studies and evidence that suggests that due to their power, intermediaries transfer risks and unexpected costs to farmers which compromise the innovation...

  3. International standard for future automotive 42 V supply voltages (PowerNet)

    Science.gov (United States)

    Bremer, Wolfgang

    The development of innovative automotive systems is determined by the demand for cut in fuel consumption and increase in fuel efficiency, reduction of environmental pollution and comfort improvement. A basic condition for such developments is the introduction of a 42 V power supply in future vehicles. The characteristics of future power supplies and the resulting consequences for the system, the components and the whole vehicle power supply architecture need standardisation in different areas. The electrical stress for the vehicle components is addressed in the standard ISO 21848 and this paper gives details about the status of the standardisation work.

  4. Voltage ripple compensation for grid connected electrolyser power supply using small DC link capacitor

    DEFF Research Database (Denmark)

    Török, Lajos; Mathe, Laszlo; Munk-Nielsen, Stig

    2014-01-01

    The purpose of this work was to investigate a three-phase-grid connected power supply using small DC link capacitor for electrolyser application. The hydrogen generation system requires low voltage and high current power supply. Thus the structure of the 3-phase power supply is defined as follows......: a three phase rectification, a small DC-link capacitor and a phase-shifted full-bridge converter with current doubler rectification. Design constraints and control problems are investigated. The advantages and problems caused by the use of small DC link capacitor are presented. The control of the system...

  5. New Design of a Low Cost Analogue Current Supply for Power LEDs

    Directory of Open Access Journals (Sweden)

    Radu Bogdan Dragomir

    2013-04-01

    Full Text Available The present paper proposes an innovative and inductive ballast-based power LED supply. This new design LED powering solution is a cost-efficient alternative to high-end switching mode power supply (SMPS used to feed LED clusters. The current supply circuit topology will be explained. The AC component of the LED current is analysed both from the ballast inductance and the value of the DC filtering capacitor standpoint. The PSIM and MATLAB tools have been used to simulate the circuit output when different ballast voltage conditions will be applied. Transitory and steady-state driver performances have been taken into account.

  6. Research on the Defects Restraining Ability of Power Supply Transacting Electrocircuit

    Institute of Scientific and Technical Information of China (English)

    GAO Jun; CHEN Chuan-bo

    2006-01-01

    Adopting the mechanism model and the system identification method, the power supply transacting electrocircuit (integrate manostat) is analyzed, and the restraining ability and the response for power supply transacting electrocircuit to overcome various battery defects are studied. The effects of the power supply yawp on the normal functions of the radio fuze are investigated. The research indicate that the shortcomings of the integration manostat as battery defects can be regarded as steady noise, and the restraining ability of the integration manostat to battery defects isn't less than 50 dB.

  7. On the building of Momoyama hydraulic power station on Kiso river. Kisogawa Momoyama suiryoku hatsudensho no kenchiku ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Kotera, T. (Nagoya University, Nagoya (Japan). Faculty of Engineering)

    1991-09-30

    This paper investigates Momoyama hydraulic power station built on the middle reaches of the Kiso River in Uematsu-cho, Kiso-gun, Nagano Prefecture in Japan, in 1923 by relating to the feature of the building of the hydraulic power station and the architect, Shiro Sato. The hydraulic power station originally was a functional and industrial building which puts a priority on the efficiency of business economy, at the same time it was often required to present a beautiful appearance. The building of Momoyama hydraulic power station was founded on the crane girder structure covered with reinforced concrete(RC) walls. A Hat roof of RC slab was applied to the roof of the building. It was generally designed in Neo-Gothic style. More specifically, however, the wall surface was designed in church style and the upper part was like a castle in the middle ages. Therefore the total design was eclectic. The outer surfaces of the building were remained to be bare concrete as cast. Such a multiple building symbolizes the situation of Japanes architecture in the 1920s. 4 figs.

  8. Supply Chain Cooperation between Coal Enterprise and Electric Power Enterprise in China

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Based on the two-stage Stackelberg game method, value creation of supply chain cooperation between coal enterprise and power utilities is studied by formulating profit functions of coal and power enterprises and calculating the maximum profit. According to the analysis, it is found that the profit from supply chain cooperation between coal and power enterprises is more than that of non-cooperation. The cooperation is validated to be beneficial for both units; however, the profit is mainly taken by the power enterprise. Thus, it is necessary to set up the incentive mechanism to distribute cooperation value between coal and power enterprises to promote their continual cooperation.

  9. The Way to Relieve Tense Supply Situation of Power and Coal in China

    Institute of Scientific and Technical Information of China (English)

    Lu Min

    2005-01-01

    This paper introduces the situation of coal and power production, the tense supply of powercoal and deteriorated coal quality in 2004, analyzes the causes of tense supply of power and coal, one ofwhich is due to the government regulated power tariff against rapid escalation of coal price that powerenterprises can hardly afford. It also presents some policy proposals to relieve the contradiction betweencoal and power, including to intensify macroscopic regulation between industries and regions, solve theproblem of power coal transportation and reduction or exemption of tax on coal industry and circulationlinks, through secondary distribution to regulate profit difference among industries.

  10. Rural power supply with local management: Examples from Bolivia, India and Nepal

    Energy Technology Data Exchange (ETDEWEB)

    Gerger, Aa.; Gullberg, M.

    1997-08-01

    Local management of rural power supply is being evaluated in a joint research project conducted by Tanzania Electric Supply Company Limited (TANESCO) and Stockholm Environment Institute (SEI) on new approaches to management and organization of rural electrification. The study is based on literature, and on data from eight visited local organizations for management of power supply in Bolivia (4), India (1) and Nepal (3). Common for these countries is that the national, rural electrification programmes have encountered difficulties. Governments have failed to generate enough funds from existing power supply systems to cover the cost for a continued rural electrification. In cases where large private companies exist, they have had few incentives for expanding into rural areas since it is often not profit making. A third category may be defined as local initiators to power supply, private or co-operative. In all these countries, locally managed power supply systems have developed as a complement to governmental and other large scale programmes. The national policies pertaining to rural power supply in general and local management thereof in particular are described for each country. From the study, it appears that local management of rural power supply is a feasible approach in developing countries. Local management of rural power supply can slightly lower the costs of electrification, and it may help accelerate the pace of load development in newly electrified areas. For successful local organizations though, the most significant factor appears to be local peoples` willingness to develop their own area. Important though, is that proper financial and technical assistance is provided the local organizations. Crucial for sound external assistance is that the national rural electrification policies are clear and consistent. 53 refs, 1 fig, 11 tabs

  11. Dynamics of global supply chain and electric power networks: Models, pricing analysis, and computations

    Science.gov (United States)

    Matsypura, Dmytro

    In this dissertation, I develop a new theoretical framework for the modeling, pricing analysis, and computation of solutions to electric power supply chains with power generators, suppliers, transmission service providers, and the inclusion of consumer demands. In particular, I advocate the application of finite-dimensional variational inequality theory, projected dynamical systems theory, game theory, network theory, and other tools that have been recently proposed for the modeling and analysis of supply chain networks (cf. Nagurney (2006)) to electric power markets. This dissertation contributes to the extant literature on the modeling, analysis, and solution of supply chain networks, including global supply chains, in general, and electric power supply chains, in particular, in the following ways. It develops a theoretical framework for modeling, pricing analysis, and computation of electric power flows/transactions in electric power systems using the rationale for supply chain analysis. The models developed include both static and dynamic ones. The dissertation also adds a new dimension to the methodology of the theory of projected dynamical systems by proving that, irrespective of the speeds of adjustment, the equilibrium of the system remains the same. Finally, I include alternative fuel suppliers, along with their behavior into the supply chain modeling and analysis framework. This dissertation has strong practical implications. In an era in which technology and globalization, coupled with increasing risk and uncertainty, complicate electricity demand and supply within and between nations, the successful management of electric power systems and pricing become increasingly pressing topics with relevance not only for economic prosperity but also national security. This dissertation addresses such related topics by providing models, pricing tools, and algorithms for decentralized electric power supply chains. This dissertation is based heavily on the following

  12. Strategic stockpiling of power system supplies for disaster recovery

    Energy Technology Data Exchange (ETDEWEB)

    Bent, Russell W [Los Alamos National Laboratory; Coffrein, Carleton [Los Alamos National Laboratory; Van Hentenryck, Pascal [BROWN UNIV

    2010-11-23

    This paper studies the Power System Stochastic Storage Problem (PSSSP), a novel application in power restoration which consists of deciding how to store power system components throughout a populated area to maximize the amount of power served after disaster restoration. The paper proposes an exact mixed-integer formulation for the linearized DC power flow model and a general column-generation approach. Both formulations were evaluated experimentally on benchmarks using the electrical power infrastructure of the United States and disaster scenarios generated by state-of-the-art hurricane simulation tools similar to those used by the National Hurricane Center. The results show that the column-generation algorithm produces near-optimal solutions quickly and produces orders of magnitude speedups over the exact formulation for large benchmarks. Moreover, both the exact and the column-generation formulations produce significant improvements over greedy approach and hence should yield significant benefits in practice.

  13. Trends in the use of digital technology for control and regulation of power supplies.

    Energy Technology Data Exchange (ETDEWEB)

    Carwardine, J.; Lenkszus, F.

    1999-10-22

    Since the availability of computers, accelerator power supplies have relied on digital technology in some way, from such simple tasks as turning the supplies on and off to the supplying of computer-controlled references. However, advances in digital technology, both in performance and cost, allow considerably more than simple control and monitoring. This, coupled with increasing demand for higher performance and monitoring capabilities, has made it appealing to integrate such technology into power supply designs. This paper will review current trends in the use of such advanced technology as embedded DSP controllers, and the application of real-time algorithms to the regulation and control of power supplies for accelerators and other large-scale physics applications.

  14. Intelligent uninterruptible power supply system with back-up fuel cell/battery hybrid power source

    Science.gov (United States)

    Zhan, Yuedong; Guo, Youguang; Zhu, Jianguo; Wang, Hua

    2008-05-01

    This paper presents the development of an intelligent uninterruptible power supply (UPS) system with a hybrid power source that comprises a proton-exchange membrane fuel cell (PEMFC) and a battery. Attention is focused on the architecture of the UPS hybrid system and the data acquisition and control of the PEMFC. Specifically, the hybrid UPS system consists of a low-cost 60-cell 300 W PEMFC stack, a 3-cell lead-acid battery, an active power factor correction ac-dc rectifier, a half-bridge dc-ac inverter, a dc-dc converter, an ac-dc charger and their control units based on a digital signal processor TMS320F240, other integrated circuit chips, and a simple network management protocol adapter. Experimental tests and theoretical studies are conducted. First, the major parameters of the PEMFC are experimentally obtained and evaluated. Then an intelligent control strategy for the PEMFC stack is proposed and implemented. Finally, the performance of the hybrid UPS system is measured and analyzed.

  15. STAND-ALONE POWER SUPPLY SYSTEM BASED ON RENEWABLE ENERGY SOURCES

    Directory of Open Access Journals (Sweden)

    Grigorash O. V.

    2013-11-01

    Full Text Available The article discusses a promising direction, aimed at improving the operational and technical characteristics of the autonomous power supply systems, through the use of a part of their gas piston power plants, wind pow-er and solar photovoltaic installations

  16. Power Supply Changes for NSTX Resistive Wall Mode Coils

    Energy Technology Data Exchange (ETDEWEB)

    Ramakrishnan, S S.

    2013-06-28

    The National Spherical Torus Experiment (NSTX) has been designed and installed in the existing facilities at Princeton Plasma Physics Laboratory (PPPL). Most of the hardware, plant facilities, auxiliary sub-systems, and power systems originally used for the Tokamak Fusion Test Reactor (TFTR) have been used with suitable modifications to reflect NSTX needs. Prior to 2004, the NSTX power system was feeding twelve (12) circuits in the machine. In 2004 the Resistive Wall Mode (RWM) Coils were installed on the machine to correct error fields. There are six of these coils installed around the machine in the mid-plane. Since these coils need fast and accurate controls, a Switching Power Amplifier (SPA) with three sub-units was procured, installed and commissioned along with other power loop components. Two RWM Coils were connected in series and fed from one SPA sub-unit. After the initial RWM campaign, operational requirements evolved such that each of the RWM coils now requires separate power and control. Hence a second SPA with three sub-units has been procured and installed. The second unit is of improved design and has the controls and power components completely isolated. The existing thyristor rectifier is used as DC Link to both of the Switching Power Amplifiers. The controls for the RWM are integrated into the overall computer control of the DC Power systems for NSTX. This paper describes the design changes in the RWM Power system for NSTX.

  17. A real time status monitor for transistor bank driver power limit resistor in boost injection kicker power supply

    Energy Technology Data Exchange (ETDEWEB)

    Mi, J.; Tan, Y.; Zhang, W.

    2011-03-28

    For years suffering of Booster Injection Kicker transistor bank driver regulator troubleshooting, a new real time monitor system has been developed. A simple and floating circuit has been designed and tested. This circuit monitor system can monitor the driver regulator power limit resistor status in real time and warn machine operator if the power limit resistor changes values. This paper will mainly introduce the power supply and the new designed monitoring system. This real time resistor monitor circuit shows a useful method to monitor some critical parts in the booster pulse power supply. After two years accelerator operation, it shows that this monitor works well. Previously, we spent a lot of time in booster machine trouble shooting. We will reinstall all 4 PCB into Euro Card Standard Chassis when the power supply system will be updated.

  18. Assessing Resilience in Power Grids as a Particular Case of Supply Chain Management

    Science.gov (United States)

    2010-03-01

    grids share basic characteristics with Supply Chain Management. This thesis presents a linear programming model to assess power grid resilience as a...particular case of Supply Chain Management. Since resilient behavior is not an individual or specific system’s attribute but a holistic phenomenon based

  19. Rethinking Rectification: AC-DC Power Supply in Package

    DEFF Research Database (Denmark)

    Pejtersen, Jens; Knott, Arnold; Jørgensen, Ivan Harald Holger

    Rectification of AC mains voltage is almost exclusively implemented with passive diode bridge rectifiers for power applications below 100 W. The diode bridge rectifier is reliable, cost effective and easy to use. But it is also lossy, nonlinear and passive. Thus reducing the power conversion...

  20. Dynamics of electromagnetic slip coupling for hydraulic power steering application and its energy-saving characteristics

    Institute of Scientific and Technical Information of China (English)

    TANG Bin; JIANG Hao-bin; XU Zhe; GENG Guo-qing; XU Xing

    2015-01-01

    To improve high-speed road feel and enhance energetic efficiency of hydraulic power steering (HPS) system in heavy-duty vehicles, an electromagnetic slip coupling (ESC) was applied to the steering system, which regulated discharge flow of steering pump to realize variable assist characteristic as well as uniquely transfer on-demand power from engine to steering pump. The model of ESC was established and the dynamic characteristics of ESC were presented by the way of simulation and experiment. Upon the layout of the assist characteristics, output torque of ESC was derived. Based on the ESC model, the output torque characteristics of ESC were simulated under steering situation and straight driving situation, respectively. The consistency of simulated ESC output torque and the one deduced from assist characteristics verifies the correctness of the ESC dynamic model. To illustrate energy saving characteristics of ESC-HPS, energy consumption comparison of ESC-HPS and conventional HPS was carried out qualitatively and quantitatively. It follows that the energy consumption of ESC-HPS decreases by 50% compared with that of HPS.

  1. Engineering Design of the ITER AC/DC Power Supply System

    Energy Technology Data Exchange (ETDEWEB)

    Oh, B. H.; Lee, K. W.; Chang, D. S.; Jin, J. T.; Hwang, C. K.

    2010-02-15

    To design high power pulse power supplies, especially in huge power supplies have not designed till now, it is necessary to analyze a system's characteristics and relations with another systems as well as to know high voltage, high current control technologies. Contents of this project are; - Analysis of the changed designs of the AC/DC converters. - Setup of the PSIM model for the calculation of the junction temperature of the converter thyristors. - Finalize the converter's simulation modules and estimate the parallel number of an arm for each converter. - Fix the protection sequence and make a simulation. - Stability check of the power distribution system against the reactive power effect. - Design of small size hardware AC/DC converter. The results of these studies may used as one of references for practical designs of the power supplies and also used for developing Tokamak type fusion reactors in the future

  2. Vehicle roof with solar power supply and contact device. Fahrzeugdach mit Solarstromquelle und Kontakteinrichtung

    Energy Technology Data Exchange (ETDEWEB)

    Paetz, W.; Meiler, K.; Schumacher, T.; Bienert, H.; Hirschberger, A.; Pfisterer, H.; Hoeller, M.

    1991-05-02

    Vehicle roof with at least one cover, carrying a solar power supply for optional covering or at least for partial uncovering of a roof opening. In addition, with at least one load driven by the solar power supply which is arranged separately from the cover and with a contact device for establishing of an electric connection between the solar power supply and the load. The contact device is designed as a switching configuration and the cover is a part of this switching configuration, so that depending on the adjustment motion of the cover, the load is connected to the solar power supply in one or several predetermined cover positions, and is disconnected in all other covert positions.

  3. AC Power Supply for Wobbler Magnet of the MC-50 Cyclotron

    CERN Document Server

    Kim, Yu-Seok; Kang, Bong-Koo; Lee, Hong-Gi; Park, Ki-Hyeon; Wha Chung, Chin; Woo Lee, Wol

    2005-01-01

    The MC-50 cyclotron (k=50) produces the ion beam for nuclear physics, chemistry, and applied researches in Korea. It has a small beam diameter with Gaussian beam shape, whereas many users want a beam irradiation on a large target. A wobbler magnet and an AC power supply were designed and constructed to meet the users' requirement. The power supply has two independently operating channels for the vertical and horizontal coils of the wobbler magnet. The frequency of the AC power supply for both coils is programmable from 1 to 20 Hz in a step of 1 Hz, and the maximum rms output current is 12 A. Various properties of the power supply and experimental results are given in the paper.

  4. RADIATION RESISTANT LED POWER SUPPLY RELEASED UNDER CERN OPEN HARDWARE LICENSE

    CERN Multimedia

    2016-01-01

    As part of the design of a new emergency lighting system for the CERN accelerator complex a new design for a radiation resistant power supply has been produced. The design is available from the Open Hardware Repository.

  5. Power supply design for the filament of the high-voltage electron accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Lige; Yang, Lei; Yang, Jun, E-mail: jyang@mail.hust.edu.cn; Huang, Jiang; Liu, Kaifeng; Zuo, Chen

    2015-12-21

    The filament is a key component for the electron emission in the high-voltage electron accelerator. In order to guarantee the stability of the beam intensity and ensure the proper functioning for the power supply in the airtight steel barrel, an efficient filament power supply under accurate control is required. The paper, based on the dual-switch forward converter and synchronous rectification technology, puts forward a prototype of power supply design for the filament of the high-voltage accelerator. The simulation is conducted with MATLAB-Simulink on the main topology and the control method. Loss analysis and thermal analysis are evaluated using the FEA method. Tests show that in this prototype, the accuracy of current control is higher than 97.5%, and the efficiency of the power supply reaches 87.8% when the output current is 40 A.

  6. Startup experience with the MFTF-B ECRH 100 kV dc power supply

    Energy Technology Data Exchange (ETDEWEB)

    Bishop, S.R.; Goodman, R.A.; Wilson, J.H.

    1983-11-30

    One of the 24 Accel dc Power Supplies (ADCPS) originally intended for the Mirror Fusion Test Facility (MFTF-B) Neutral Beam Power Supply (NBPS) System has been converted to provide negative polarity output at 90 kV with a load current of 64 A dc. The load duty cycle is a pulse of 30-seconds duration with a pulse repetition period of five minutes. A new control system has been built which will serve as a prototype for the MFTF-B ADCPS controls, and a test setup was built which will be used to test the ADCPS. The Electron Cyclotron Resonance Heating (ECRH) dc Power Supply (DCPS) has been tested under both no-load and dummy-load conditions, under remote control, without notable problems. Test results indicate that the power supply should be reliable and safe to operate, and will meet the load duty requirements.

  7. The role of wind energy in the programme of power supply of northern Russia territories

    Energy Technology Data Exchange (ETDEWEB)

    Bezroukikh, P. [Ministry for Fuel and Energy, Moscow (Russian Federation)

    1995-12-31

    In this article examined technical, management and economic problems has been arising during working out of above mentioned Power Supply Programm based on the renewable energy sources usage and proved the leading role of wind energy in this Programm. (author)

  8. Control system of HLS transport line and Linac focusing power supplies

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The control system of transport line and Linac focusing power supplies of Hefei Light Source was built upon Experimental Physics and Industrial Control System. The hardware construction, software design and performance test of the control system are described.

  9. A new topology and control method for electromagnetic transmitter power supplies

    Science.gov (United States)

    Zhang, Yiming; Zhang, Jialin; Yuan, Dakang

    2017-04-01

    As essential equipment for electromagnetic exploration, electromagnetic transmitter reverse the steady power supply with desired frequency and transmit the power through grounding electrodes. To obtain effective geophysical data during deep exploration, the transmitter needs to be high-voltage, high-current, with high-accuracy output, and yet compact and light. The researches on the power supply technologies for high-voltage high-power electromagnetic transmitter is of significant importance to the deep geophysical explorations. Therefore, the performance of electromagnetic transmitter is mainly subject to the following two aspects: the performance of emission current and voltage, and the power density. These requirements bring technical difficulties to the development of power supplies. Conventionally, high-frequency switching power supplies are applied in the design of a high-power transmitter power supply. However, the structure of the topology is complicate, which may reduce the controllability of the output voltage and the reliability of the system. Without power factor control, the power factor of the structure is relatively low. Moreover high switching frequency causes high loss. With the development of the PWM (pulse width modulation) technique, its merits of simple structure, low loss, convenient control and unit power factor have made it popular in electrical energy feedback, active filter, and power factor compensation. Studies have shown that using PWM converters and space vector modulation have become the trend in designing transmitter power supply. However, the earth load exhibits different impedances at different frequencies. Thus ensuing high-accuracy and a stable output from a transmitter power supply in harsh environment has become a key topic in the design of geophysical exploration instruments. Based on SVPWM technology, an electromagnetic transmitter power supply has been designed and its control strategy has been studied. The transmitting

  10. Recurrent-neural-network-based identification of a cascade hydraulic actuator for closed-loop automotive power transmission control

    Energy Technology Data Exchange (ETDEWEB)

    You, Seung Han [Hyundai Motor Company, Seoul (Korea, Republic of); Hahn, Jin Oh [University of Alberta, Edmonton (Canada)

    2012-05-15

    By virtue of its ease of operation compared with its conventional manual counterpart, automatic transmissions are commonly used as automotive power transmission control system in today's passenger cars. In accordance with this trend, research efforts on closed-loop automatic transmission controls have been extensively carried out to improve ride quality and fuel economy. State-of-the-art power transmission control algorithms may have limitations in performance because they rely on the steady-state characteristics of the hydraulic actuator rather than fully exploit its dynamic characteristics. Since the ultimate viability of closed-loop power transmission control is dominated by precise pressure control at the level of hydraulic actuator, closed-loop control can potentially attain superior efficacy in case the hydraulic actuator can be easily incorporated into model-based observer/controller design. In this paper, we propose to use a recurrent neural network (RNN) to establish a nonlinear empirical model of a cascade hydraulic actuator in a passenger car automatic transmission, which has potential to be easily incorporated in designing observers and controllers. Experimental analysis is performed to grasp key system characteristics, based on which a nonlinear system identification procedure is carried out. Extensive experimental validation of the established model suggests that it has superb one-step-ahead prediction capability over appropriate frequency range, making it an attractive approach for model-based observer/controller design applications in automotive systems.

  11. Performance and modelling of 70kVdc power supply with solid-state crowbar

    Energy Technology Data Exchange (ETDEWEB)

    Yellamraju, Sham Sunder Srinivas, E-mail: ysssrinivas@gmail.com [Institute for Plasma Research, BHAT, Gandhinagar 382428 (India); Kulkarni, Sanjay V. [Institute for Plasma Research, BHAT, Gandhinagar 382428 (India)

    2013-10-15

    The experimental activities of tokamak research involve development of high power RF and microwave sources for fusion related heating and current drive applications. High power RF and microwave tubes like Klystron, Gyrotron and Tetrode are in general operated with high voltage DC power supplies. These HVDC power supplies of the order of 70 kVdc, must be equipped with necessary arc fault protection in addition to general over current and over voltage protection. The arc fault protection must act within few microseconds to prevent permanent damage to the RF tube, window, etc. When an arc fault is detected, output voltage of the DC power supply is short circuited using a crowbar device (generally Ignitron, Thyratron, thyristor, rail-gap, etc.) that operates in few microseconds. This diverts the fault current from the load to crowbar device, thereby protecting the load. This is necessary as conventional protection in the power supply input takes ∼100 ms to switch-off. The crowbar device must be able to take the fault current till the circuit breaker placed at power supply input is switched off. The arc fault protection is tested for its effectiveness by “wire-burn” test. Full power short circuit of ∼1.5 MW DC power supply puts enormous stress on the power supply, utility and the crowbar, therefore frequent wire-burn testing is to be avoided. This report presents simulation of wire-burn test using PSIM software. Optimization of the component values without conducting actual wire-burn test could be achieved.

  12. Decentral power stores. Key components of future power supply concepts; Dezentrale Energiespeicher. Schluesselkomponenten fuer die Stromversorgung der Zukunft

    Energy Technology Data Exchange (ETDEWEB)

    Huschke, Reinhard

    2011-07-01

    The book presents the most relevant power storage technologies, i.e. their advantages, shortcomings and possible applications. The focus is on decentral power stores that can be used wherever electric power must be stored, independent of local conditions. Although this concept does not play much of a role today, it will become more relevant in the context of increasingly decentral power supply. For 2020, a minimum share of 30 percent renewable energy in German power supply is required by law, while other scenarios assume an even bigger share. The present storage reserve capacity will not be sufficient for this. The book also goes into the applications of power storage systems in the fields of electromobility and in future, more decentral power grids. (orig.)

  13. Design of a System for Auto-patrolling Power Supplies and Displaying Beam Status In HIRFL

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    A practical application for patrolling the device’s status and displalying beam status of HIRFL has been described.With regard to the kinds of the controlled devices,the system consists of two parts:First,the alarm system is applied to monitor all power supplies,which are decomposed into six groups in accordance with their positions for the convenience of user’s operation.The amount of magnet lens and power supplies of pre-beam

  14. Photovoltaic power supply for appliances and small systems. Final report; Photovoltaik fuer Geraete und Kleinsysteme. Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Roth, W.; Anton, L.; Benz, J.; Kaiser, R.; Kuhmann, J.; Puls, H.G.; Pfanner, N.; Schmidt, H.; Schulz, W.; Steinhueser, A.

    2002-06-01

    The economic prospects of PV power supply to appliances and small systems were investigated. The research project was aimed at improving the conditions for efficient development of appliances and small systems with photovoltaic power supply and autonomous systems not connected to the grid. Innovative products were developed and tested in cooperation with industrial organizations. The project is to help small and medium-sized organizations with a technological orientation and enhance technology transfer between science and industry.

  15. Power supply and quench protection for the Wendelstein 7-X magnet

    Energy Technology Data Exchange (ETDEWEB)

    Nitsche, A.; Sapper, J. [Max-Planck-Institut fuer Plasmaphysik, Garching (Germany)

    1998-07-01

    The superconducting main and auxiliary field coils of the new stellarator Wendelstein 7-X to be placed in Greifswald, Germany are subdivided into seven coil groups. They are magnetically coupled by the toroidal field, but they will be fed by seven independent power supplies each with an individual quench protection circuit. The lay-out for the power supply and the coil protection system is presented. (author)

  16. The 10 millisecond 150 kiloampere pulsed power supply for the Fermilab neutrino focusing horn

    CERN Document Server

    Trendler, R C

    1979-01-01

    A number of schemes were examined to provide a long current pulse for the Horn. These included multiple power supplies, larger capacitor banks as well as the selected design, a pulse transformer. The pulse transformer scheme was selected because modification to the existing short pulse power supply were minimized as well as the fact that a pulse transformer with nearly the desired characteristics has been built and utilized at CERN. (4 refs).

  17. Finite Element Modeling of Dynamic Properties of Power Supply for an Industrial Application

    OpenAIRE

    2014-01-01

    In this thesis, the dynamic properties of the mechanic structure of Power Supply for an Industrial Application, an Alstom company product, are considered. A finite element model of the Power Supply mechanic structure have been generated with the aid of the MSC Marc software. Based on the FE model; modal analysis have been carried out and the eigenfrequencies and eigenmodes for the FE model have been calculated in a suitable frequency range. Relevant frequency response functions for the FE mod...

  18. Economic Viability of Pumped-Storage Power Plants Equipped with Ternary Units and Considering Hydraulic Short-Circuit Operation

    Science.gov (United States)

    Chazarra, Manuel; Pérez-Díaz, Juan I.; García-González, Javier

    2017-04-01

    This paper analyses the economic viability of pumped-storage hydropower plants equipped with ternary units and considering hydraulic short-circuit operation. The analysed plant is assumed to participate in the day-ahead energy market and in the secondary regulation service of the Spanish power system. A deterministic day-ahead energy and reserve scheduling model is used to estimate the maximum theoretical income of the plant assuming perfect information of the next day prices and the residual demand curves of the secondary regulation reserve market. Results show that the pay-back periods with and without the hydraulic short-circuit operation are significantly lower than their expected lifetime and that the pay-back periods can be reduced with the inclusion of the hydraulic short-circuit operation.

  19. Operation Optimization Based on the Power Supply and Storage Capacity of an Active Distribution Network

    Directory of Open Access Journals (Sweden)

    Wenpeng Yu

    2013-12-01

    Full Text Available Due to the interconnection and active management of Distributed Generation (DG and Energy Storage Systems (ESSs, the traditional electrical distribution network has become an Active Distribution Network (ADN, posing challenges to the operation optimization of the network. The power supply and storage capacity indexes of a Local Autonomy Control Region (LACR, which consists of DGs, ESSs and the network, are proposed in this paper to quantify the power regulating range of a LACR. DG/ESS and the network are considered as a whole in the model of the indexes, considering both network constraints and power constraints of the DG/ESS. The index quantifies the maximum LACR power supplied to or received from ADN lines. Similarly, power supply and storage capacity indexes of the ADN line are also proposed to quantify the maximum power exchanged between ADN lines. Then a practical algorithm to calculate the indexes is presented, and an operation optimization model is proposed based on the indexes to maximum the economic benefit of DG/ESS. In the optimization model, the power supply reliability of the ADN line is also considered. Finally, the indexes of power supply and storage capacity and the optimization are demonstrated in a case study.

  20. Design of an implantable power supply for an intraocular sensor, using POWER (power optimization for wireless energy requirements)

    Energy Technology Data Exchange (ETDEWEB)

    Albano, F. [Department of Material Science Engineering, University of Michigan, Ann Arbor, MI 48109 (United States); Chung, M.D. [Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109 (United States); Blaauw, D.; Sylvester, D.M. [Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, MI 48109 (United States); Wise, K.D. [Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109 (United States); Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, MI 48109 (United States); Sastry, A.M. [Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109 (United States); Department of Material Science Engineering, University of Michigan, Ann Arbor, MI 48109 (United States); Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109 (United States)

    2007-06-30

    The reduction in size and power usage of MEMS (microelectromechanical systems) devices has enabled development of fully implantable medical devices [K.D. Wise, IEEE Eng. Med. Biol. Magaz. 24(5) (2005) 22-29], though major obstacles remain in developing devices of very small scale (<1 mm) [T. Simunic, L. Benini, G. De Micheli, IEEE Trans. Very Large Scale Integr. (VLSI) Syst. 9 (2001) 15-28]. One of the most challenging applications; an intraocular sensor (IOS) developed by the Wireless Integrated Micro-Systems-Engineering Research Center (WIMS-ERC) at The University of Michigan; is the subject of the present study. Our specific objectives are fourfold: (1) to model the power usage of an intraocular sensor (IOS); (2) to develop a methodology for optimization of Hybrid Implantable Power Systems (HIPS); (3) to apply the selection tool to identify candidate power systems; and (4) to establish a methodology to fabricate and test the performance of an optimized power supply. In the present study we fabricated and tested three different cells. For one of these, 10 complete discharge and recharge cycles were successfully obtained. The experimental capacity was 7.70 mAh (15% of theoretical) for a discharge rate of C/5. As part of future work, a microbattery will be built for the WIMS-ERC IOS and tested in a fully integrated testbed. (author)

  1. Assessment of the cogeneration biogas plant possibilities in the autonomous power supply system

    Directory of Open Access Journals (Sweden)

    Sumarokova Liudmila

    2017-01-01

    Full Text Available The use of biomass and wood waste for heat and power production is increasing from year to year. Waste wood is low carbon footprint, has low sulfur content and relates to renewable energy sources. The paper demonstrates the possibility of increasing the energy efficiency of power supply system of the Stepanovka settlement (Tomsk region by means of replacing diesel power plant (DPP by the biofuel gas piston CHP. The assessment was based on the possibility of the technical and economic comparison of power supply options in the settlement.

  2. Twenty-first century power needs. Challenges, and supply options

    Energy Technology Data Exchange (ETDEWEB)

    Criswell, D.R. [Houston Univ., TX (United States). Solar Energy Lab.

    1997-11-01

    The challenge of providing adequate power to enable world prosperity in the twenty-first century to continue was discussed. It was estimated that by 2050, a prosperous world of 10 billion people will require 60 TWt of thermal power. Conventional power systems will not be able to provide the needed energy because of limited fuels, contamination of the biosphere and costs. A viable, cost effective alternative will be solar energy that is captured in space and from facilities on the Moon, and that is imported to Earth by microwaves. Global electric power systems that use the Moon and deliver 1,000 TWe-Y of energy by 2070 was suggested as the most obvious alternative. Despite the huge initial cost of 20 to 100 trillion dollars, the long-term cost was said to be small compared to terrestrial and Earth-orbital options. 30 refs., 2 figs.

  3. Research on Risk Management and Power Supplying Enterprise Control

    Science.gov (United States)

    Shen, Jianfei; Wang, Yige

    2017-09-01

    This paper derived from the background that electric power enterprises strengthen their risk management under requirements of the government. For the power industry, we explained the risk management theory, analysed current macro environment as well as basic situation, then classified and interpreted the main risks. In a case study on a power bureau, we established a risk management system based on deep understanding about the characteristics of its organization system and risk management function. Then, we focused on risks in operation as well as incorrupt government construction to give a more effective framework of the risk management system. Finally, we came up with the problems and specific countermeasures in risk management, which provided a reference for other electric power enterprises.

  4. ESB-Based Sensor Web Integration for the Prediction of Electric Power Supply System Vulnerability

    Science.gov (United States)

    Stoimenov, Leonid; Bogdanovic, Milos; Bogdanovic-Dinic, Sanja

    2013-01-01

    Electric power supply companies increasingly rely on enterprise IT systems to provide them with a comprehensive view of the state of the distribution network. Within a utility-wide network, enterprise IT systems collect data from various metering devices. Such data can be effectively used for the prediction of power supply network vulnerability. The purpose of this paper is to present the Enterprise Service Bus (ESB)-based Sensor Web integration solution that we have developed with the purpose of enabling prediction of power supply network vulnerability, in terms of a prediction of defect probability for a particular network element. We will give an example of its usage and demonstrate our vulnerability prediction model on data collected from two different power supply companies. The proposed solution is an extension of the GinisSense Sensor Web-based architecture for collecting, processing, analyzing, decision making and alerting based on the data received from heterogeneous data sources. In this case, GinisSense has been upgraded to be capable of operating in an ESB environment and combine Sensor Web and GIS technologies to enable prediction of electric power supply system vulnerability. Aside from electrical values, the proposed solution gathers ambient values from additional sensors installed in the existing power supply network infrastructure. GinisSense aggregates gathered data according to an adapted Omnibus data fusion model and applies decision-making logic on the aggregated data. Detected vulnerabilities are visualized to end-users through means of a specialized Web GIS application. PMID:23955435

  5. Conceptual design and circuit analyses for the power supplies of the NIO1 experiment

    Energy Technology Data Exchange (ETDEWEB)

    Recchia, M., E-mail: mauro.recchia@igi.cnr.it [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy); Bigi, M. [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy); Cavenago, M. [INFN-LNL, Viale dell' Universita 2, 35020 Legnaro (Italy)

    2011-10-15

    The NIO1 (Negative Ion Optimization phase 1) experiment, whose construction has started in 2010 at Consorzio RFX in Padova in collaboration with INFN-LNL, is a radio frequency Hydrogen negative ion source designed to produce a beam current of 130 mA with 60 keV particle energy. The aim of the experiment is to provide a highly flexible system to test material properties of source components and to benchmark simulation codes for beam optics and plasma behavior. The paper focuses on a conceptual design for NIO1 power supply system on the basis of given operational and performance requirements. The requested ratings fall well within those of products available on the market and the design includes standard commercial solutions for the individual power supplies. The ion source operates at -60 kV with respect to ground, leading to a number of design issues at system level and related to mutual connection between power supplies and load, layout and grounding. These aspects, along with the crucial point of ensuring protection to the arc prone beam source, are reviewed and discussed. The study leads to a scheme integrating high voltage power supplies, high current power supplies and a possible solution for passive protection components at the power supply output.

  6. ESB-Based Sensor Web Integration for the Prediction of Electric Power Supply System Vulnerability

    Directory of Open Access Journals (Sweden)

    Milos Bogdanovic

    2013-08-01

    Full Text Available Electric power supply companies increasingly rely on enterprise IT systems to provide them with a comprehensive view of the state of the distribution network. Within a utility-wide network, enterprise IT systems collect data from various metering devices. Such data can be effectively used for the prediction of power supply network vulnerability. The purpose of this paper is to present the Enterprise Service Bus (ESB-based Sensor Web integration solution that we have developed with the purpose of enabling prediction of power supply network vulnerability, in terms of a prediction of defect probability for a particular network element. We will give an example of its usage and demonstrate our vulnerability prediction model on data collected from two different power supply companies. The proposed solution is an extension of the GinisSense Sensor Web-based architecture for collecting, processing, analyzing, decision making and alerting based on the data received from heterogeneous data sources. In this case, GinisSense has been upgraded to be capable of operating in an ESB environment and combine Sensor Web and GIS technologies to enable prediction of electric power supply system vulnerability. Aside from electrical values, the proposed solution gathers ambient values from additional sensors installed in the existing power supply network infrastructure. GinisSense aggregates gathered data according to an adapted Omnibus data fusion model and applies decision-making logic on the aggregated data. Detected vulnerabilities are visualized to end-users through means of a specialized Web GIS application.

  7. ESB-based Sensor Web integration for the prediction of electric power supply system vulnerability.

    Science.gov (United States)

    Stoimenov, Leonid; Bogdanovic, Milos; Bogdanovic-Dinic, Sanja

    2013-08-15

    Electric power supply companies increasingly rely on enterprise IT systems to provide them with a comprehensive view of the state of the distribution network. Within a utility-wide network, enterprise IT systems collect data from various metering devices. Such data can be effectively used for the prediction of power supply network vulnerability. The purpose of this paper is to present the Enterprise Service Bus (ESB)-based Sensor Web integration solution that we have developed with the purpose of enabling prediction of power supply network vulnerability, in terms of a prediction of defect probability for a particular network element. We will give an example of its usage and demonstrate our vulnerability prediction model on data collected from two different power supply companies. The proposed solution is an extension of the GinisSense Sensor Web-based architecture for collecting, processing, analyzing, decision making and alerting based on the data received from heterogeneous data sources. In this case, GinisSense has been upgraded to be capable of operating in an ESB environment and combine Sensor Web and GIS technologies to enable prediction of electric power supply system vulnerability. Aside from electrical values, the proposed solution gathers ambient values from additional sensors installed in the existing power supply network infrastructure. GinisSense aggregates gathered data according to an adapted Omnibus data fusion model and applies decision-making logic on the aggregated data. Detected vulnerabilities are visualized to end-users through means of a specialized Web GIS application.

  8. Disparity of isoflurane effects on left and right ventricular afterload and hydraulic power generation in swine.

    Science.gov (United States)

    Heerdt, P M; Gandhi, C D; Dickstein, M L

    1998-09-01

    The interaction between myocardial and vascular effects of anesthetics has a potential impact on how these drugs influence performance of the heart. Most studies have focused on volatile anesthetic effects on the left ventricle (LV) and systemic circulation. Whether the right ventricle (RV) and pulmonary circulation respond in a similar fashion, however, is unclear. In the present study, we therefore examined the dose-related effects of isoflurane on LV and RV contractility and total afterload and related changes to simultaneous effects on the hydraulic power generated by each chamber. Two groups of swine were studied: one received no additional treatment before isoflurane (ISO, n = 6), and the other received hexamethonium, atropine, and propranolol to produce autonomic blockade before isoflurane administration (ISO+AB, n = 4). For each experiment, measurements were made of RV and LV regional segment lengths and pressures, along with proximal aortic and pulmonary arterial (PA) blood flow and pressure during the administration of 0, 0.5, 1.0, and 1.5 minimum alveolar anesthetic concentration (MAC) isoflurane. Contractility was assessed by calculating the regional preload recruitable stroke work slope (PRSW). Afterload was characterized in both nonpulsatile and pulsatile terms by calculating aortic input impedance magnitude (Z). From these data, total arterial resistance (R), characteristic impedance (ZC), and vascular compliance (C) were determined with reference to a three-element Windkessel model of the circulation. Additionally, steady-state (WSS), oscillatory (WOS), and total (WT) hydraulic power output of each ventricle was calculated. In the ISO group, isoflurane produced a nearly threefold greater decrease of peak systolic pressure in the LV than in the RV, yet the dose-related decrease of regional PRSW was virtually the same in both chambers. In the aorta, isoflurane produced a maximal 25% reduction in R at 1.0 MAC and doubled C without a significant change

  9. Advantages of using a two-switch forward in single-stage power factor corrected power supplies

    DEFF Research Database (Denmark)

    Petersen, Lars

    2000-01-01

    A single-stage power factor corrected power supply using a two-switch forward is proposed to increase efficiency. The converter is operated in the DCM (discontinues conduction mode) and it is shown that this operation mode ensures the intermediate DC-bus to be controlled only by means of circuit...

  10. Design and Implementation of Fuzzy Logic Controlled Uninterruptible Power Supply Integrating Renewable Solar Energy

    Directory of Open Access Journals (Sweden)

    Angelo A. Beltran Jr.

    2014-03-01

    Full Text Available —The control and operation of electronic systems relies and depends on the availability of the power supply. Rechargeable batteries have been more pervasively used as the energy storage and power source for various electrical and electronic systems and devices, such as communication systems, electronic devices, renewable power systems, electric vehicles, etc. However, the rechargeable batteries are subjected to the availability of the external power source when it is drained out. Because of the concern of battery life, environmental pollution and a possible energy crisis, the renewable solar energy has received an increasing attention in recent years. A fuzzy logic control based grid tied uninterruptible power supply integrating renewable solar energy can be used for electrical and electronic systems to produce power generation. This paper presents the design and implementation of fuzzy logic control based grid tied uninterruptible power supply integrating the renewable solar power energy system. The uninterruptible power supply (UPS system is characterized by the rechargeable battery that is connected with the Photovoltaic Panel through the DC/DC converter, the utility AC through the AC/DC converter and the load is connected through the DC/AC converter. The whole operation is controlled by the fuzzy logic algorithm. A complete hardware prototype system model of the fuzzy logic control based on the grid tied uninterruptible power supply integrating with the renewable solar energy is designed and implemented. The operation and effectiveness of the proposed system is then demonstrated by the actual and real time implementation of the fuzzy logic control grid tied operation uninterruptible power supply integrating renewable solar energy connected to the rechargeable battery bank and a PIC microcontroller platform for fuzzy logic control and operation

  11. Development of HV power transmission technology. Electric power supply until first world war; Entwicklung der Hochspannungsuebertragungstechnik. Die Elektroenergieversorgung bis zum Ersten Weltkrieg

    Energy Technology Data Exchange (ETDEWEB)

    Dittmann, Frank [Deutsches Museum, Muenchen (Germany)

    2009-11-02

    Story of power supply from 1880 to 1935 in Germany starting first with light centers, first public plants for power utilization followed by steam power plants and erection of overhead power lines. (GL)

  12. A simple, robust and reliable wind diesel concept for remote power supply

    DEFF Research Database (Denmark)

    Lundsager, P.; Bindner, H.

    1994-01-01

    The paper introduces a Wind Diesel concept suitable for remote communities, the 'Simple, Robust and Reliable Concept' developed at Riso. All components are standard components, the system is self regulating using the component controllers and there is no power electronics. The paper documents...... a performance in terms of fuel savings and power quality that makes the concept a commercially viable option for including wind power in remote power supply systems....

  13. Design and Implementation of Fuzzy Logic Controlled Uninterruptible Power Supply Integrating Renewable Solar Energy

    OpenAIRE

    Angelo A. Beltran Jr.; Felicito S. Caluyo

    2014-01-01

    —The control and operation of electronic systems relies and depends on the availability of the power supply. Rechargeable batteries have been more pervasively used as the energy storage and power source for various electrical and electronic systems and devices, such as communication systems, electronic devices, renewable power systems, electric vehicles, etc. However, the rechargeable batteries are subjected to the availability of the external power source when ...

  14. Multimegawatt space nuclear power supply, Phase 1 Final report

    Energy Technology Data Exchange (ETDEWEB)

    1989-02-17

    This Specification establishes the performance, design, development, and test requirements for the Boeing Multimegawatt Space Nuclear Power System (MSNPS). The Boeing Multimegawatt Space Power System is part of the DOE/SDIO Multimegawatt Space Nuclear Power Program. The purpose of this program is to provide a space-based nuclear power system to meet the needs of SDIO missions. The Boeing MSNPS is a category 1 concept which is capable of delivering 10's of MW(e) for 100's of seconds with effluent permitted. A design goal is for the system to have growth or downscale capability for other power system concepts. The growth objective is to meet the category 3 capability of 100's of MW(e) for 100's of seconds, also with effluent permitted. The purpose of this preliminary document is to guide the conceptual design effort throughout the Phase 1 study effort. This document will be updated through out the study. It will thus result in a record of the development of the design effort.

  15. 重要电力用户保供电管理%Power supply management of the crucial power costomer

    Institute of Scientific and Technical Information of China (English)

    党林

    2012-01-01

    According to the "Options about strengthening the configuration, monitoring and managing crucial power customer power supply and emergency power supply" and the "three safety production bottom line " , which is " guaranteeing personal safety, preventing large scale black - out, ensuring power supply of the crucial power customer" put forwarded by the China Southern Power Grid Co. , Ltd and combining with the practical situation of the Guizhou power grid, the paper analyzes the power customer management and improves the power supply ability to the crucial power customers.%按照国家电监会《关于加强重要电力客户供电电源及自备应急电源配置监督管理的意见》(电监安全[2008]43号)和南方电网公司提出的“坚守切实保证人身安全、坚决防止大面积停电事故、保证重要用户供电”的“三条安全生产底线”要求,结合贵州电网实际,探索重要电力用户管理,提升重要电力用户保供电能力和水平。

  16. Design of Bandgap Reference in Switching Power Supply

    Institute of Scientific and Technical Information of China (English)

    XU Li; NIU Ping-juan; FU Xian-song; DING Ke; PENG Xiao-lei

    2009-01-01

    A bandgap voltage reference is designed to meet the requirements of low power loss,low temperature coefficient and high power source rejection ratio(PSRR) in the intergrated circuit.Based on the analysis of conventional bandgap reference circuit,and combined with the integral performance of IC,the specific design index of the bandgap reference is put forward.In the meantime,the circuit and the layout are designed with Chartered 0.35 μm dual gate CMOS process.The simulation result shows that the coefficient is less than 30ppm/℃ with the temperature from -50℃ to 150℃. The bandgap reference has the characteristics of low power and high PSRR.

  17. REDUCED-PARTS SINGLE-PHASE UNINTERRUPTIBLE POWER SUPPLY

    Directory of Open Access Journals (Sweden)

    DANIEL ALBU

    2008-05-01

    Full Text Available Reducing the number of switches andpassive elements in uninterruptible power supplytopologies not only reduces the cost of the wholesystem but also provides some other advantagessuch as greater compactness, smaller weight, andhigher reliability. Generally, the largest costreduction is achieved by reducing the number ofswitches employed in a converter power circuit.Another way of reducing the cost of converters is touse a topology that allows replacing activeswitches, such as IGBTs, MOSFETs, andthyristors, with diodes. Diodes are less expensivethan active switches and apart from this, there isalso a cost reduction from eliminating all thecircuitry for driving active switches.

  18. Output regulation of large-scale hydraulic networks with minimal steady state power consumption

    NARCIS (Netherlands)

    Jensen, Tom Nørgaard; Wisniewski, Rafał; De Persis, Claudio; Kallesøe, Carsten Skovmose

    2014-01-01

    An industrial case study involving a large-scale hydraulic network is examined. The hydraulic network underlies a district heating system, with an arbitrary number of end-users. The problem of output regulation is addressed along with a optimization criterion for the control. The fact that the syste

  19. Simultaneous transient operation of a high head hydro power plant and a storage pumping station in the same hydraulic scheme

    Science.gov (United States)

    Bucur, D. M.; Dunca, G.; Cervantes, M. J.; Cǎlinoiu, C.; Isbǎşoiu, E. C.

    2014-03-01

    This paper presents an on-site experimental analysis of a high head hydro power plant and a storage pumping station, in an interconnected complex hydraulic scheme during simultaneous transient operation. The investigated hydropower site has a unique structure as the pumping station discharges the water into the hydropower plant penstock. The operation regimes were chosen for critical scenarios such as sudden load rejections of the turbines as well as start-ups and stops with different combinations of the hydraulic turbines and pumps operation. Several parameters were simultaneously measured such as the pumped water discharge, the pressure at the inlet pump section, at the outlet of the pumps and at the vane house of the hydraulic power plant surge tank. The results showed the dependence of the turbines and the pumps operation. Simultaneous operation of the turbines and the pumps is possible in safe conditions, without endangering the machines or the structures. Furthermore, simultaneous operation of the pumping station together with the hydropower plant increases the overall hydraulic efficiency of the site since shortening the discharge circuit of the pumps.

  20. A flexible super-capacitive solid-state power supply for miniature implantable medical devices.

    Science.gov (United States)

    Meng, Chuizhou; Gall, Oren Z; Irazoqui, Pedro P

    2013-12-01

    We present a high-energy local power supply based on a flexible and solid-state supercapacitor for miniature wireless implantable medical devices. Wireless radio-frequency (RF) powering recharges the supercapacitor through an antenna with an RF rectifier. A power management circuit for the super-capacitive system includes a boost converter to increase the breakdown voltage required for powering device circuits, and a parallel conventional capacitor as an intermediate power source to deliver current spikes during high current transients (e.g., wireless data transmission). The supercapacitor has an extremely high area capacitance of ~1.3 mF/mm(2), and is in the novel form of a 100 μm-thick thin film with the merit of mechanical flexibility and a tailorable size down to 1 mm(2) to meet various clinical dimension requirements. We experimentally demonstrate that after fully recharging the capacitor with an external RF powering source, the supercapacitor-based local power supply runs a full system for electromyogram (EMG) recording that consumes ~670 μW with wireless-data-transmission functionality for a period of ~1 s in the absence of additional RF powering. Since the quality of wireless powering for implantable devices is sensitive to the position of those devices within the RF electromagnetic field, this high-energy local power supply plays a crucial role in providing continuous and reliable power for medical device operations.

  1. Solid polyelectrolyte fuel cell power supply system; Kotai kobunshigata nenryo denchi dengen system

    Energy Technology Data Exchange (ETDEWEB)

    Aoki, T. [Kanagawa (Japan); Kadoma, H. [Yokohama (Japan); Hashizaki, K.; Tani, T. [Mitsubishi Heavy Industries Ltd., Tokyo (Japan)

    1996-06-11

    When a previous solid polyelectrolyte fuel cell power supply system is used underwater, the water generated by the cell reaction is stored in a water storage tank and it is necessary that the system is suspended in case the generated water is full in the water storage tank to take the system out of water and the water in the tank is discharged in the atmosphere. The solid polyelectrolyte fuel cell power supply system of this invention is equipped with a discharge pump to exhaust the generated water out of the closed vessel accommodating the system or equipped with a device to exhaust the generated water into the outside water accompanied with gushing of high-pressure gas into the outside water. As a result, the water generated by the cell reaction can be exhausted from the system into the outside water at any required time so that the fuel cell power supply system can be operated continuously as far as the supply of the fuel or the oxidizer last. By the installment of this function, a solid polyelectrolyte fuel cell power supply system can be used as an independent underwater power source or as a power source for an underwater moving body. 4 figs.

  2. Advanced simulation of windmills in electric power supply

    DEFF Research Database (Denmark)

    Akhmatov, Vladislav; Knudsen, Hans; Nielsen, Arne Hejde

    2000-01-01

    -connected windmills as a part of realistic electrical grid models. That means an arbitrary number of wind farms or single windmills within an arbitrary network configuration. The windmill model may be applied to study of electric power system stability and of power quality as well. It is found that a grid......-connected windmill operates as a low-pass filter, whereby two following observations are made: 1. interaction between the electrical grid and the mechanical systems of grid-connected windmills is given by a low frequency oscillation as the result of disturbances in the electric grid; 2. flicker, which is commonly......An advanced model of a grid-connected windmill is set up where the windmill is a complex electro-mechanical system. The windmill model is implemented as a standardised component in the dynamic simulation tool, PSS/E, which makes it possible to investigate dynamic behaviour of grid...

  3. Abandoned coal mine tunnels: Future heating/power Supply centers

    Institute of Scientific and Technical Information of China (English)

    Luo Pingjia; Chen Ning

    2011-01-01

    We have studied three plans for re-use of the abandoned mine roadway tunnels as an energy center.These are the thermostat plan,the thermal accumulator plan,and the CAES plan.Calculations show that the thermostat plan can provide over 15,000 m2 of building air-conditioning/heating load for each kilometer of roadway,but electric power is needed to run the system.Numerical research proved that the accumulation of hot water in the roadway for seasonal heating purposes (a temperature swing from 90 to 54 ℃) is a viable possibility.The CAES plan proposes using the discarded coal mine tunnel as a peaking power station with an energy storage density over 7000 kJ/m3.It can be concluded that presently abandoned coal mines could be reformed into future energy centers for a city.

  4. Self-Oscillating Soft Switching Envelope Tracking Power Supply for Tetra2 Base Station

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Wendelboe; Andersen, Michael Andreas E.

    2007-01-01

    ) implemented with a series inductor and an external clamping power supply. Combined with advanced power stage components (die-size MOSFETs), a high-performance fixed-frequency self-oscillating (sliding mode) control strategy and a 4th-order output filter, this leads to a compact, effective and efficient...

  5. 75 FR 56021 - Energy Conservation Standards for Battery Chargers and External Power Supplies: Public Meeting...

    Science.gov (United States)

    2010-09-15

    ..., and preliminary results. II. History of Standards Rulemaking for Battery Chargers and External Power... Part 430 RIN 1904-AB57 Energy Conservation Standards for Battery Chargers and External Power Supplies... establishing energy conservation standards for battery chargers (BCs) and non-Class A EPSs; the...

  6. High performance AC–DC control power supply for low voltage ride through inverters

    Indian Academy of Sciences (India)

    K Saichand; Akshay Kumrawat; Vinod John

    2016-02-01

    This paper presents a control power supply (CPS) design which is used to feed power to the subsystems of a power converter. The CPS design presented here maintains a constant 24Vdc output even over a wide (90Vrms to 270Vrms ) ac voltage variation at its input for a High Power Converter (HPC). The circuit design and closed loop control design of such a CPS are presented. During starting, the power supply to the control circuitry of the CPS in turn is obtained using a separate start-up power supply. The various design issues and details of the on-board power supply and start-up power circuit to ensure the reliable start-up and shut down of the CPS are analyzed. The CPS was tested for wide input voltage range (vin) and the performance validates the design. The CPS has also been tested for an input side voltage sag and its performance allows the HPC to meet the low voltage ride-through requirements.

  7. Water constraints on European power supply under climate change: impacts on electricity prices

    NARCIS (Netherlands)

    Vliet, van M.T.H.; Vögele, S.; Rübbelke, D.

    2013-01-01

    Recent warm, dry summers showed the vulnerability of the European power sector to low water availability and high river temperatures. Climate change is likely to impact electricity supply, in terms of both water availability for hydropower generation and cooling water usage for thermoelectric power

  8. Water constraints on European power supply under climate change: impacts on electricity prices

    NARCIS (Netherlands)

    Vliet, van M.T.H.; Vögele, S.; Rübbelke, D.

    2013-01-01

    Recent warm, dry summers showed the vulnerability of the European power sector to low water availability and high river temperatures. Climate change is likely to impact electricity supply, in terms of both water availability for hydropower generation and cooling water usage for thermoelectric power

  9. Short Pulse Switches for Airborne High Power Supplies

    Science.gov (United States)

    1973-10-01

    recovery of high pressure SF6 circuit breakers by Perkins and Frost* at the Westinghouse Research laboratories. The apparatus is shown schematically... breaker with opposite polarity and will increase the potential across the circuit breaker . The necessary data are not on hand to determine the...A.N., Lee, T.H., Theory and Application of the Commutation Principle for HVDC Circuit Brakers, Transactions Paper IEEE Power Engineering Society, 1972

  10. FLEHAP: A Wind Powered Supply for Autonomous Sensor Nodes

    Directory of Open Access Journals (Sweden)

    Gregorio Boccalero

    2016-10-01

    Full Text Available The development of the Internet of Things infrastructure requires the deployment of millions of heterogeneous sensors embedded in the environment. The powering of these sensors cannot be done with wired connections, and the use of batteries is often impracticable. Energy harvesting is the common proposed solution, and many devices have been developed for this purpose, using light, mechanical vibrations, and temperature differences as energetic sources. In this paper we present a novel energy-harvester device able to capture the kinetic energy from a fluid in motion and transform it in electrical energy. This device, named FLEHAP (FLuttering Energy Harvester for Autonomous Powering, is based on an aeroelastic effect, named fluttering, in which a totally passive airfoil shows large and regular self-sustained motions (limit cycle oscillations even in extreme conditions (low Reynolds numbers, thanks to its peculiar mechanical configuration. This system shows, in some centimeter-sized configurations, an electrical conversion efficiency that exceeds 8% at low wind speed (3.5 m/s. By using a specialized electronic circuit, it is possible to store the electrical energy in a super capacitor, and so guarantee self-powering in such environmental conditions.

  11. Power supply distribution system for calorimeters at the LHC beyond the nominal luminosity

    Energy Technology Data Exchange (ETDEWEB)

    Tenti, P; Spiazzi, G; Buso, S [Dipartimento di Ingegneria dell' Informazione, Universita degli Studi di Padova, via Gradenigo 6/b, Padova (Italy); Riva, M; Maranesi, P; Belloni, F [Departimento di Fisica, Universita degli Studi di Milano, via Celoria 16, Milano (Italy); Cova, P; Menozzi, R; Delmonte, N; Bernardoni, M [Dipartimento di Ingegneria dell' Informazione, Universita degli Studi di Parma, v.le G.P. Usberti, 181/A, Parma (Italy); Iannuzzo, F; Busatto, G; Porzio, A; Velardi, F [Dip. di Automazione, Elettromagnetismo, Ingegneria dell' Informazione e Matematica Industriale, Universita degli Studi di Cassino, via G. Di Biasio 43, Cassino (France) (Italy); Lanza, A [INFN - Sezione di Pavia, via A. Bassi 6, Pavia (Italy); Citterio, M; Meroni, C, E-mail: spiazzi@dei.unipd.it [INFN - Sezione di Milano, via Celoria 16, Milano (Italy)

    2011-06-15

    This paper investigates the use of switching converters for the power supply distribution to calorimeters in the ATLAS experiment when the Large Hadron Collider (LHC) will be upgraded beyond the nominal luminosity. Due to the highly hostile environment the converters must operate in, all the main aspects are considered in the investigation, from the selection of the switching converter topologies to the thermal analysis of components and PCBs, with attention to reliability issues of power devices subject to ionizing radiations. The analysis focuses on the particular, but crucial, case of the power supplies for calorimeters, though several outcomes of the research can profitably be applied to other detectors like muon chambers.

  12. Simulation of switching overvoltages in the mine electric power supply system

    Science.gov (United States)

    Ivanchenko, D. I.; Novozhilov, N. G.

    2017-02-01

    Overvoltages occur in mine power supply systems during switching off consumers with high inductive load, such as transformers, reactors and electrical machines. Overvoltages lead to an increase of insulation degradation rate and may cause electric faults, power outage, fire and explosion of methane and coal dust. This paper is dedicated to simulation of vacuum circuit breaker switching overvoltages in a mine power supply system by means of Simulink MATLAB. The model of the vacuum circuit breaker implements simulation of transient recovery voltage, current chopping and an electric arc. Obtained results were compared to available experimental data.

  13. Performance evaluation of time-delay control schemes for uninterruptible power supplies

    DEFF Research Database (Denmark)

    Loh, P.C; Tang, Y.; Blaabjerg, Frede

    2008-01-01

    Uninterruptible power supplies (UPSs) are commonly used to supply quality power at a well-regulated voltage to all nonlinear and unbalanced loads. To achieve that, a number of control schemes have since been proposed with the traditional double-loop linear control scheme being more popular because...... a more powerful processor. Avoiding these added complexities, this paper presents and compares a number of time-delay control schemes for UPS control, where the main building blocks needed are readily available memory storages and simple transfer functions formulated with either no or at least one...

  14. Reduced heat stress in offices in the tropics using solar powered drying of the supply air.

    Science.gov (United States)

    Gunnarsen, L; Santos, A M B

    2002-12-01

    Many solutions to indoor climate problems known from developed countries may have prohibitive installation and running costs in developing countries. The purpose was to develop a low-cost solution to heat stress in a hot and humid environment based on solar powered drying of supply air. Dry supply air may facilitate personal cooling by increased evaporation of sweat. Heat acclimatized people with efficient sweating may in particular benefit from this cooling. A prototype solar powered supply system for dried-only air was made. Air from the system was mixed with room air, heated to six different combinations of temperature and humidity and led to Personal Units for Ventilation and Cooling (PUVAC) in six cubicles simulating office workplaces. A total of 123 heat acclimatized subjects were exposed 45 min in each of the cubicles. A model for the combined effect of operative temperature of room, moisture content of room air, temperature of supply air and moisture content of supply air was developed based on the experiments. Reduction of moisture content in the supply air by 1.6 g/kg had the same effect as lowering the operative temperature by 1 degree C. The solar-powered system for supplying dry air is a low-cost alternative to traditional air conditioning in hot and humid regions.

  15. Forest biomass supply logistics for a power plant using the discrete-event simulation approach

    Energy Technology Data Exchange (ETDEWEB)

    Mobini, Mahdi [Industrial Engineering Group, Department of Wood Science, University of British Columbia, 2943-2424 Main Mall, Vancouver, BC V6T-1Z4 (Canada); Sowlati, Taraneh [Department of Wood Science, University of British Columbia, 2931-2424 Main Mall, Vancouver, BC V6T-1Z4 (Canada); Sokhansanj, Shahab [Department of Chemical and Biological Engineering, University of British Columbia, 2360 East Mall, Vancouver, BC V6T 1Z3 (Canada); Environmental Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States)

    2011-04-15

    This study investigates the logistics of supplying forest biomass to a potential power plant. Due to the complexities in such a supply logistics system, a simulation model based on the framework of Integrated Biomass Supply Analysis and Logistics (IBSAL) is developed in this study to evaluate the cost of delivered forest biomass, the equilibrium moisture content, and carbon emissions from the logistics operations. The model is applied to a proposed case of 300 MW power plant in Quesnel, BC, Canada. The results show that the biomass demand of the power plant would not be met every year. The weighted average cost of delivered biomass to the gate of the power plant is about C$ 90 per dry tonne. Estimates of equilibrium moisture content of delivered biomass and CO{sub 2} emissions resulted from the processes are also provided. (author)

  16. Forest biomass supply logistics for a power plant using the discrete-event simulation approach

    Energy Technology Data Exchange (ETDEWEB)

    Mobini, Mahdi [University of British Columbia, Vancouver; Sowlati, T. [University of British Columbia, Vancouver; Sokhansanj, Shahabaddine [ORNL

    2011-04-01

    This study investigates the logistics of supplying forest biomass to a potential power plant. Due to the complexities in such a supply logistics system, a simulation model based on the framework of Integrated Biomass Supply Analysis and Logistics (IBSAL) is developed in this study to evaluate the cost of delivered forest biomass, the equilibrium moisture content, and carbon emissions from the logistics operations. The model is applied to a proposed case of 300 MW power plant in Quesnel, BC, Canada. The results show that the biomass demand of the power plant would not be met every year. The weighted average cost of delivered biomass to the gate of the power plant is about C$ 90 per dry tonne. Estimates of equilibrium moisture content of delivered biomass and CO2 emissions resulted from the processes are also provided.

  17. A HIGH BANDWIDTH BIPOLAR POWER SUPPLY FOR THE FAST CORRECTORS IN THE APS UPGRADE*

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Ju; Sprau, Gary

    2017-06-25

    The APS Upgrade of a multi-bend achromat (MBA) storage ring requires a fast bipolar power supply for the fast correction magnets. The key performance requirement of the power supply includes a small-signal bandwidth of 10 kHz for the output current. This requirement presents a challenge to the design because of the high inductance of the magnet load and a limited input DC voltage. A prototype DC/DC power supply utilizing a MOSFET H-bridge circuit with a 500 kHz PWM has been developed and tested successfully. The prototype achieved a 10-kHz bandwidth with less than 3-dB attenuation for a signal 0.5% of the maximum operating current of 15 amperes. This paper presents the design of the power circuit, the PWM method, the control loop, and the test results.

  18. Development of high voltage power supply for the KSTAR 170 GHz ECH and CD system

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, J.H., E-mail: jhjeong@nfri.re.kr [National Fusion Research Institute, Daejeon (Korea, Republic of); Bae, Y.S.; Joung, M.; Kim, H.J.; Park, S.I.; Han, W.S.; Kim, J.S.; Yang, H.L.; Kwak, J.G. [National Fusion Research Institute, Daejeon (Korea, Republic of); Sakamoto, K.; Kajiwara, K.; Oda, Y.; Hayashi, K. [Japan Atomic Energy Agency, Naka (Japan)

    2013-06-15

    Highlights: • A 3.6 MW (−66 kV/55 A) gyrotron power supply system was developed for the 170 GHz ECH system in KSTAR. • The main power supply includes a total of 32 PSM based HV power supply modules. • The voltage regulation of individual HV power module and LV power module is 3 kV and 0.5 kV, respectively. • The gyrotron is protected by means of a fast solid-state switch (MOS-FET). • The HV switching system can turn off the 60 kV to the cathode within 3 μs in the event of gyrotron faults. -- Abstract: A 3.6 MW (66 kV/55 A) DC power supply system was developed for the 170 GHz EC H and CD system in KSTAR. The power supply system consists of a cathode power supply (CPS), an anode power supply (APS) and a body power supply (BPS). The cathode power supply is capable of supplying a maximum voltage of −66 kV and a current of 55 A to the cathode with respect to the collector using pulse step modulation (PSM). The high voltage switching system for the cathode is made by a fast MOS-FET solid-state switch which can turn off the high voltage to the cathode within 3 μs in the occurrence of gyrotron faults. The APS is a voltage divider system consisting of a fixed resistor and zener diode units with the capability of 60 kV stand-off voltage. The anode voltage with respect to the cathode is controlled in a range of 0–60 kV by turning the MOS-FET switches connected in parallel to each zener diode on and off. For high frequency current modulation of the gyrotron, the parallel discharge switch is introduced between the cathode and anode in order to clamp the charged voltage in the stray capacitance. The BPS is a DC power supply with the capability of 50 kV/160 mA. The nominal operation parameter of BPS was 23 kV and 10 mA, respectively, and the voltage output is regulated with a stability of 0.025% of the rated voltage. The series MOS-FET solid-state switch is used for on/off modulation in the body voltage sychronizing with anode voltage. The parallel discharge

  19. Research on Two-channel Interleaved Two-stage Paralleled Buck DC-DC Converter for Plasma Cutting Power Supply

    DEFF Research Database (Denmark)

    Yang, Xi-jun; Qu, Hao; Yao, Chen

    2014-01-01

    As for high power plasma power supply, due to high efficiency and flexibility, multi-channel interleaved multi-stage paralleled Buck DC-DC Converter becomes the first choice. In the paper, two-channel interleaved two- stage paralleled Buck DC-DC Converter powered by three-phase AC power supply...

  20. How to ensure secure and diverse power supply for Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Kiss, Peter; Sagodi, Attila

    2010-09-15

    The Brazilian electricity market, the largest in Latin America with a total annual demand of some 425,000 GWh, appears set for steady and sustainable expansion, supported by a combination of both economic and population growth along with government measures to increase the availability of electricity to the wider public. Though it is vital to maintain its regulatory stability and to further improve its energy policy in order to be able to keep up with the expected demand growth. While Brazil's heavy reliance on hydroelectric power will continue, opportunities for other generating systems are already opening up and are likely to increase.

  1. Solar battery power supply: A reliable power supply system for nursing clinic in Australia`s remote areas

    Energy Technology Data Exchange (ETDEWEB)

    Zahedi, A. [Monash Univ., Caulfield (Australia). Div. of Electrical and Computer Systems Engineering

    1997-12-31

    Design and performance investigation of a new solar-battery system to power health clinics in Australia`s remote and isolated areas is a research project being conducted in the Department. The objective of this paper is to present the solar-battery system and to discuss the design factors of the system.

  2. ECONOMIC PRINCIPLES FOR SELECTION OF OPTIMUM POWER-SUPPLY SYSTEM DEVELOPMENT IN BELARUS

    Directory of Open Access Journals (Sweden)

    L. P. Padalko

    2008-01-01

    Full Text Available The paper considers main directions of the technological development of the Belarusian power-supply system. Comparative analysis of the economic efficiency of thermal power station modernization on the basis of steam- and gas technology, nuclear technology development and simple renovation of the worn-out generating capacities of thermal power stations has been carried out in the paper. Selection of the priority direction pertaining to optimization of industrial structure of the Belarusian power-supply system has been made on the basis of the presented minimum-specific cost criterion. The paper reveals that in the medium-term period the most optimum development of the Belarusian electrical power engineering is a technological  modernization  due to predicted  changes in natural gas and nuclear fuel costs. The modernization presupposes construction of topping plants in addition to the existing steam- and turbine equipment at thermal power stations. 

  3. Thermal-hydraulics, physical chemistry, and technology at nuclear power stations equipped with fast-neutron sodium-cooled reactors

    Science.gov (United States)

    Alekseev, V. V.; Efanov, A. D.; Kozlov, F. A.; Sorokin, A. P.

    2007-12-01

    Main results of investigations aimed at developing a verified system of computer codes that take into account the interrelation among nuclear-physical, thermal-hydraulic, physicochemical, thermal-mechanical, mass-transfer, and technological processes in nuclear power installations and at substantiating the models used as the core of these codes are presented together with the results of tests carried out to obtain data for verifying the codes.

  4. A METHOD FOR QUALITY POWER PROVIDER TO OPERATE IN DISTORTED SUPPLY CONDITION

    Directory of Open Access Journals (Sweden)

    K.CHANDRASEKARAN

    2011-08-01

    Full Text Available Power Quality is a major concern within power industry and consumers. Poor quality of supply will affect the performance of customer equipment such as computers, microprocessors, adjustable speed drives, power electronic controllers, life saving equipment in hospitals, etc. and result in heavy financial losses to customers due to loss of production or breakdown in industries or loss of life in a hospital. The two major power quality disturbances are voltage sag and harmonic distortion. In this paper, a Quality Power Provider (QPP based on voltage source inverter is modeled by simulation to compensate the power quality disturbances such as voltage sag and voltage harmonics in the distorted supply condition. The phase locked loop (PLL is an important control unit of the QPP control scheme. To obtain accurate phase information and frequency of the input supply, the dqPLL method has been proposed. Simulation results based on MATLAB and PSCAD software are presented to verify the performance of the proposed QPP. QPP has improved the quality of power supply at the sensitive load end.

  5. A combined compensation method for the output voltage of an insulated core transformer power supply

    Science.gov (United States)

    Yang, L.; Yang, J.; Liu, K. F.; Qin, B.; Chen, D. Z.

    2014-06-01

    An insulated core transformer (ICT) power supply is an ideal high-voltage generator for irradiation accelerators with energy lower than 3 MeV. However, there is a significant problem that the structure of the segmented cores leads to an increase in the leakage flux and voltage differences between rectifier disks. A high level of consistency in the output of the disks helps to achieve a compact structure by improving the utilization of both the rectifier components and the insulation distances, and consequently increase the output voltage of the power supply. The output voltages of the disks which are far away from the primary coils need to be improved to reduce their inhomogeneity. In this study, by investigating and comparing the existing compensation methods, a new combined compensation method is proposed, which increases the turns on the secondary coils and employs parallel capacitors to improve the consistency of the disks, while covering the entire operating range of the power supply. This method turns out to be both feasible and effective during the development of an ICT power supply. The non-uniformity of the output voltages of the disks is less than 3.5% from no-load to full-load, and the power supply reaches an output specification of 350 kV/60 mA.

  6. Power Supply for Magnet of Compact Proton and/or Heavy Ion Synchrotron for Radiotherapy

    CERN Document Server

    Yamanaka, Shinji; Endo, Kuninori; Fang, Zhigao

    2005-01-01

    A resonant type pulse power supply, for an application to a compact proton and/or heavy ion synchrotron with a several Hz repetition rate, is attractive from the view point of attaining an average beam current that is enough for the radiation therapy. Maximum ampere-turn of the dipole magnet is as large as 200 kAT to make the bending radius as small as possible. Pulse current is generated by discharging the stored energy in a capacitor bank through a pulse transformer. Moreover, the auxiliary power supply for the dipole magnets which adds the flat magnetic field (10-20μs) for the multi-turn beam-injection is being developed. The power supply for the quadrupole magnets is the high switching frequency (20 kHz × 5) switching-mode Power Supply for the adjusting tune and the tracking between the quadrupole and the dipole fields.Detailed analyses on these pulse power supplies will be presented.

  7. The damping of power swings in electrical energy supply systems. Daempfung von Leistungspendelungen in elektrischen Energieversorgungssystemen

    Energy Technology Data Exchange (ETDEWEB)

    Wohlfarth, H.

    1987-10-12

    The author examines the method of operation and usefulness of power system stabilisers (PSS), which are used for damping power swings in electrical energy supply systems. Various model components, such as generators, voltage regulation, turbine regulation etc., are first considered. The damping of magnet wheel swings by power system stabilisers is then dealt with. Investigations of PSS individual components in the time range are introduced and the multi-machine problem is discussed. (HAG).

  8. EFFECT OF POWER SUPPLY AND DUTY CONTROL IN CRANKCASE FLOW (CRANKCASE PRESSURE PORT OF ECV

    Directory of Open Access Journals (Sweden)

    MD. IQBAL MAHMUD

    2016-06-01

    Full Text Available The electromagnetic control valve (ECV operated by solenoid in the external variable compressor with the swash plate type is the rising phenomenon. ECV controls the air conditioning compressor for automobile on the basis of the input signal of the pulse width modulation (PWM that supplied from the external controller. PWM technique is used to encode the information for transmission; its main use is to allow the control of the power to be supplied to electrical devices, especially to inertial loads. The mechanism changes the swash plate angle inside the compressor by increasing or reducing the pressure of swash plate chamber by use of the functions of different pressure port within the ECV. Increasing and reducing the swash plate angle finally depends on the solenoid force acting on the rate of supply of current. This research paper investigates the effect of power supply and duty control during the crankcase flowing at Pc pressure port of ECV.

  9. Explosive Ferroelectric Power Supply of Flux Compression Generator

    Institute of Scientific and Technical Information of China (English)

    WANG De-wu; HE Yuan-ji; TAN Hui-min

    2007-01-01

    Useful electrical pulses of a few hundred kilowatts lasting for several microseconds can be obtained by the depolarization process of PZT95/5 ferroelectric ceramics. In this paper, taking account of the dielectric relaxation, and finite resistance, a new mathematical model of PZT95/5 ferroelectric ceramics subjected to normal-mode shock wave is suggested. Explosive shock wave techniques have also been used to investigate the response of PZT95/5 ferroelectric ceramics with inductive loads in experiments. The predictions from the model have a good agreement with observed results. In addition, an explosive ferroelectric generator composed of explosive shock wave generators, electric units, and additional capacitors is design to power small-size helical flux compression generators. The test results with the maximal output energy of up to 80J are given and experimental results are also considered.

  10. Modeling Innovative Power Take-Off Based on Double-Acting Hydraulic Cylinders Array for Wave Energy Conversion

    Directory of Open Access Journals (Sweden)

    Juan Carlos Antolín-Urbaneja

    2015-03-01

    Full Text Available One of the key systems of a Wave Energy Converter for extraction of wave energy is the Power Take-Off (PTO device. This device transforms the mechanical energy of a moving body into electrical energy. This paper describes the model of an innovative PTO based on independently activated double-acting hydraulic cylinders array. The model has been developed using a simulation tool, based on a port-based approach to model hydraulics systems. The components and subsystems used in the model have been parameterized as real components and their values experimentally obtained from an existing prototype. In fact, the model takes into account most of the hydraulic losses of each component. The simulations show the flexibility to apply different restraining torques to the input movement depending on the geometrical configuration and the hydraulic cylinders on duty, easily modified by a control law. The combination of these two actions allows suitable flexibility to adapt the device to different sea states whilst optimizing the energy extraction. The model has been validated using a real test bench showing good correlations between simulation and experimental tests.

  11. Optimization Design of an Inductive Energy Harvesting Device for Wireless Power Supply System Overhead High-Voltage Power Lines

    Directory of Open Access Journals (Sweden)

    Wei Wang

    2016-03-01

    Full Text Available Overhead high voltage power line (HVPL online monitoring equipment is playing an increasingly important role in smart grids, but the power supply is an obstacle to such systems’ stable and safe operation, so in this work a hybrid wireless power supply system, integrated with inductive energy harvesting and wireless power transmitting, is proposed. The energy harvesting device extracts energy from the HVPL and transfers that from the power line to monitoring equipment on transmission towers by transmitting and receiving coils, which are in a magnetically coupled resonant configuration. In this paper, the optimization design of online energy harvesting devices is analyzed emphatically by taking both HVPL insulation distance and wireless power supply efficiency into account. It is found that essential parameters contributing to more extracted energy include large core inner radius, core radial thickness, core height and small core gap within the threshold constraints. In addition, there is an optimal secondary coil turn that can maximize extracted energy when other parameters remain fixed. A simple and flexible control strategy is then introduced to limit power fluctuations caused by current variations. The optimization methods are finally verified experimentally.

  12. Simulations of thermal-hydraulic processes in heat exchangers- station of the cogeneration power plant

    Energy Technology Data Exchange (ETDEWEB)

    Studovic, M.; Stevanovic, V.; Ilic, M.; Nedeljkovic, S. [Faculty of Mechanical Engineering of Belgrade (Croatia)

    1995-12-31

    Design of the long district heating system to Belgrade (base load 580 MJ/s) from Thermal Power Station `Nikola Tesla A`, 30 km southwest from the present gas/oil burning boilers in New Belgrade, is being conducted. The mathematical model and computer code named TRP are developed for the prediction of the design basis parameters of heat exchangers station, as well as for selection of protection devices and formulation of operating procedures. Numerical simulations of heat exchangers station are performed for various transient conditions: up-set and abnormal. Physical model of multi-pass, shell and tube heat exchanger in the station represented is by unique steam volume, and with space discretised nodes both for water volume and tube walls. Heat transfer regimes on steam and water side, as well as hydraulic calculation were performed in accordance with TEMA standards for transient conditions on both sides, and for each node on water side. Mathematical model is based on balance equations: mass and energy for lumped parameters on steam side, and energy balances for tube walls and water in each node. Water mass balance is taken as boundary/initial condition or as specified control function. The physical model is proposed for (s) heat exchangers in the station and (n) water and wall volumes. Therefore, the mathematical model consists of 2ns+2, non-linear differential equations, including equations of state for water, steam and tube material, and constitutive equations for heat transfer on steam and water side, solved by the Runge-Kutt method. Five scenarios of heat exchangers station behavior have been simulated with the TRP code and obtained results are presented. (author)

  13. High-Bandwidth, High-Efficiency Envelope Tracking Power Supply for 40W RF Power Amplifier Using Paralleled Bandpass Current Sources

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Wendelboe; Andersen, Michael Andreas E.

    2005-01-01

    This paper presents a high-performance power conversion scheme for power supply applications that require very high output voltage slew rates (dV/dt). The concept is to parallel 2 switching bandpass current sources, each optimized for its passband frequency space and the expected load current....... The principle is demonstrated with a power supply, designed for supplying a 40 W linear RF power amplifier for efficient amplification of a 16-QAM modulated data stream...

  14. Determination of appropriate DC voltage for switched mode power supply (SMPS) loads

    Science.gov (United States)

    Setiawan, Eko Adhi; Setiawan, Aiman; Purnomo, Andri; Djamal, Muchlishah Hadi

    2017-03-01

    Nowadays, most of modern and efficient household electronic devices operated based on Switched Mode Power Supply (SMPS) technology which convert AC voltage from the grid to DC voltage. Based on theory and experiment, SMPS loads could be supplied by DC voltage. However, the DC voltage rating to energize electronic home appliances is not standardized yet. This paper proposed certain method to determine appropriate DC voltage, and investigated comparison of SMPS power consumption which is supplied from AC and DC voltage. To determine the appropriate DC voltage, lux value of several lamps which have same specification energized by using AC voltage and the results is using as reference. Then, the lamps were supplied by various DC voltage to obtain the trends of the lux value to the applied DC voltage. After that, by using the trends and the reference lux value, the appropriate DC voltage can be determined. Furthermore, the power consumption on home appliances such as mobile phone, laptop and personal computer by using AC voltage and the appropriate DC voltage were conducted. The results show that the total power consumption of AC system is higher than DC system. The total power (apparent power) consumed by the lamp, mobile phone and personal computer which operated in 220 VAC were 6.93 VA, 34.31 VA and 105.85 VA respectively. On the other hand, under 277 VDC the load consumption were 5.83 W, 19.11 W and 74.46 W respectively.

  15. Analysis of crowbar action of high voltage DC power supply in the LHD ICRF system

    Energy Technology Data Exchange (ETDEWEB)

    Li Xiaodong [Southwestern Institute of Physics, Chengdu, Sichuan (China); Mutoh, T.; Kumazawa, R.; Watari, T.; Seki, T.; Shimpo, F.; Nomura, G.; Saito, K.

    1999-04-01

    Ion Cyclotron Range of Frequency (ICRF) heating will be applied to the Large Helical Device (LHD) at the 2nd experimental campaign in 1998. The LHD ICRF system is characterised by its high power (up to 12 MW at final stage) and steady state operation for more than 30 minutes. One of the main R and D items was a high power and steady state transmitter. The RF transmitter system having a wide frequency range from 25 to 95 MHz was designed and fabricated. This report describes the analysis of the DC power supply that contains the crowbar circuit protecting the tetrode from the arcing inside the tube. The DC power supply of the transmitter is fed from the commercial AC electric line which also supply the power to the LHD helical and poloidal coil power supplies. The voltage drop of the commercial line when the ICRF crowbar action happened is the serious problem for all experimental system. This paper analyses the crowbar effect on the commercial line with and without leakage transformer between the step-up transformer of transmitter and the commercial line. (author)

  16. Report on Performance of Prototype Dynatronix Power Supplies Developed Under a Phase I DOE SBIR

    Energy Technology Data Exchange (ETDEWEB)

    Hoppe, Eric W.; Merriman, Jason H.

    2011-03-01

    The purpose of this study is to evaluate the prototype power supplies fabricated by Dynatronix, Inc. This project supports the advancement of electroforming capabilities to produce ultra-high purity copper. Ultra-high purity copper is an essential material used for a range of current and future fundamental nuclear physics programs such as the MAJORANA DEMONSTRATOR. The Mach 30 power supplies are a new design built to the specifications from the requirements of Pacific Northwest National Laboratory (PNNL) with regard to timing, voltage, current output, and the required tolerances. The parameters used in these tests were developed empirically over a number of years based on a combination of thermodynamic and kinetics of the electroplating process. The power supplies were operated in a typical cleanroom environment for the production electroforming at PNNL. The units that were received by PNNL in July, 2010 have performed satisfactorily and have demonstrated short term durability.

  17. The Current-voltage Characteristics Simulation of the Betavoltaic Power Supply

    Directory of Open Access Journals (Sweden)

    S.U. Urchuk

    2015-12-01

    Full Text Available In order to optimize betavoltaic power supply it was calculated the current-voltage characteristics when changing the depth of the upper p-layer and at changing doping levels structure areas. It is shown that an increase in the depth reduces the short-circuit current and thus reduces the open circuit voltage. It has been observed that the concentration of the lightly doped region more significantly influence on the current-voltage characteristics than the depth of the p-n-junction. The concentration of the n-region, equal to 1014 cm – 3, can be considered as during betavoltaic power supply design. It is shown that, by increasing the power supply activity the conversion efficiency of the structure increases, too.

  18. Prognostic health monitoring in switch-mode power supplies with voltage regulation

    Science.gov (United States)

    Hofmeister, James P (Inventor); Judkins, Justin B (Inventor)

    2009-01-01

    The system includes a current injection device in electrical communication with the switch mode power supply. The current injection device is positioned to alter the initial, non-zero load current when activated. A prognostic control is in communication with the current injection device, controlling activation of the current injection device. A frequency detector is positioned to receive an output signal from the switch mode power supply and is able to count cycles in a sinusoidal wave within the output signal. An output device is in communication with the frequency detector. The output device outputs a result of the counted cycles, which are indicative of damage to an a remaining useful life of the switch mode power supply.

  19. Design and preliminary test results of the 40 MW power supply at the National High Magnetic Field Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Boenig, H.J. [Los Alamos National Lab., NM (United States); Bogdan, F.; Morris, G.C. [ABB Drives Inc., New Berlin, WI (United States); Ferner, J.A.; Schneider-Muntau, H.J. [National High Magnetic Field Lab., Tallahassee, FL (United States); Rumrill, R.H.; Rumrill, R.S. [Alpha Scientific Electronics Inc., Hayward, CA (United States)

    1993-11-01

    Four highly stabilized, steady-state, 10 MW power supplies have been installed at the National High Magnetic Field Laboratory in Tallahassee, FL. Each supply consists of a 12.5 kV vacuum circuit breaker, two three-winding, step-down transformers, a 24-pulse rectifier with interphase reactors and freewheeling diodes, and a passive and an active filter. Two different transformer tap settings allow dc supply output voltages of 400 and 500 V. The rated current of a supply is 17 kA and each supply has a one hour overload capability of 20 kA. The power supply output bus system, including a reversing switch at the input and 2 {times} 16 disconnect switches at the output, connects each supply to 16 different magnet cells. The design of the power supply is described and preliminary test results with a supply feeding a 10 MW resistive load are presented.

  20. Multi-reactor configurations for multi-megawatt spacecraft power supplies

    Science.gov (United States)

    George, Jeffrey A.

    1990-01-01

    Several conceptual designs for a multimegawatt space nuclear power supply system were developed on the basis of hardware and technology from the existing multihundred kilowatt-class SP-100 reactor program. It is shown that net power outputs in the multimegawatt range can be achieved by using a modular multireactor configuration of several SP-100-derived nuclear power supplies. A variety of geometries were examined for their applicability to the multireactor configuration, showing that modular multireactor systems have the advantage of an increased redundancy in the power system, as compared with a single-reactor system, allowing higher reliabilities than those achievable with single-reactor systems. Results are presented on the Mars Cargo Mission analysis, showing that modularity allows the option of redeployment of power systems in Mars and facilitates refurbishment and turnaround of NEP transfer vehicles.

  1. A new shunt DC active filter of power supply in a steady high magnetic field facility

    Institute of Scientific and Technical Information of China (English)

    WANG Lei; LIU Xiao-Ning; WANG Can

    2011-01-01

    A DC active power filter is an indispensable part in a high power and high stability power supply system, especially in the power supply system of the Steady High Magnetic Field Facility, which requires that the current ripple should be limited to 50 parts per million. In view of the disadvantages of the series DC active power filter and shunt Pulse Width Modulation DC active filter, this paper puts forward a novel DC active filter by combining the advantages of the transistor regulator and the shunt type. The structure and principle of the new shunt linear active filter are introduced. Meanwhile, the design of several key components that construct the new shunt linear active filter is also analyzed. The simulation model and an experimental prototype of the shunt linear active filter are developed, and the results verify that the parameter design is reasonable and the shunt active filter has a good filter effect.

  2. Investigations of DC power supplies with optoelectronic transducers and RF energy converters

    Science.gov (United States)

    Guzowski, B.; Gozdur, R.; Bernacki, L.; Lakomski, M.

    2016-04-01

    Fiber Distribution Cabinets (FDC) monitoring systems are increasingly popular. However it is difficult to realize such system in passive FDC, due to lack of source of power supply. In this paper investigation of four different DC power supplies with optoelectronic transducers is described. Two converters: photovoltaic power converter and PIN photodiode can convert the light transmitted through the optical fiber to electric energy. Solar cell and antenna RF-PCB are also tested. Results presented in this paper clearly demonstrate that it is possible to build monitoring system in passive FDC. During the tests maximum obtained output power was 11 mW. However all converters provided enough power to excite 32-bit microcontroller with ARM-cores and digital thermometer.

  3. High efficiency class-Ⅰ audio power amplifier using a single adaptive supply

    Institute of Scientific and Technical Information of China (English)

    Peng Zhenfei; Yang Shanshan; Feng Yong; Liu Yang; Hong Zhiliang

    2012-01-01

    A high efficiency class-Ⅰ linear audio power amplifier (PA) with an adaptive supply is presented.Its efficiency is improved by a dynamic supply to reduce the power transistors' voltage drop.A gain compression technique is adopted to make the amplifier accommodate a single positive supply.Circuit complicity and chip area are reduced because no charge pump is necessary for the negative supply.A common shared mode voltage and a symmetric layout pattern are used to minimize the non-linearity.A peak efficiency of 80% is reached at peak output power.The measured THD+N before and after the supply switching point are 0.01% and 0.05%,respectively.The maximum output power is 410 mW for an 8 Ω speaker load.Unlike switching amplifiers,the class-Ⅰ amplifier operates as a linear amplifier and hence has a low EMI.The advantage of a high efficiency and low EMI makes the class-Ⅰ amplifier suitable for portable and RF sensitive applications.

  4. Optimization models of the supply of power structures’ organizational units with centralized procurement

    Directory of Open Access Journals (Sweden)

    Sysoiev Volodymyr

    2013-01-01

    Full Text Available Management of the state power structures’ organizational units for materiel and technical support requires the use of effective tools for supporting decisions, due to the complexity, interdependence, and dynamism of supply in the market economy. The corporate nature of power structures is of particular interest to centralized procurement management, as it provides significant advantages through coordination, eliminating duplication, and economy of scale. This article presents optimization models of the supply of state power structures’ organizational units with centralized procurement, for different levels of simulated materiel and technical support processes. The models allow us to find the most profitable options for state power structures’ organizational supply units in a centre-oriented logistics system in conditions of the changing needs, volume of allocated funds, and logistics costs that accompany the process of supply, by maximizing the provision level of organizational units with necessary material and technical resources for the entire planning period of supply by minimizing the total logistical costs, taking into account the diverse nature and the different priorities of organizational units and material and technical resources.

  5. Research for the Cable Layout Way of the Bypass Operation System in Agricultural Power Supply Network

    Science.gov (United States)

    Niu, Jie; Li, Jinliang; Zou, Dehua; Yang, Qi; Li, Xu; Yan, Yu; Li, Tang

    2017-05-01

    Non-blackout working of agricultural power supply network is significant to shorten the outage time, decrease the outage loss, and improve the supply reliability and safety. It is impossible to hang the wire rope first and then suspend the cable because of the poor bearing ability of the pole in agricultural power supply network. A kind of new cable arrangement way, its matching tools and the flexible cable that can bear the tension by itself are needed to be put forward and developed. It is necessary to calculate the electric field intensity of the flexible cable to verify that the electric field intensity meets the insulation demand. In this new design, the fiber layer is added into the flexible cable and its maximum tension force is measured to reach to 4000 N. Based on the features of live working in the agricultural power supply network, the new layout way of the cable is proposed; the matching tools and the new flexible cable that can bear the tension by itself are developed as well in this paper. All of the research achievements can give references for the live working of the agricultural power supply network.

  6. Constant-Pressure Hydraulic Pump

    Science.gov (United States)

    Galloway, C. W.

    1982-01-01

    Constant output pressure in gas-driven hydraulic pump would be assured in new design for gas-to-hydraulic power converter. With a force-multiplying ring attached to gas piston, expanding gas would apply constant force on hydraulic piston even though gas pressure drops. As a result, pressure of hydraulic fluid remains steady, and power output of the pump does not vary.

  7. Highly efficient welding power supply. Final report, May 1, 1978-September 30, 1980

    Energy Technology Data Exchange (ETDEWEB)

    Thommes, J M

    1980-09-01

    The results and findings of an energy efficient welding power development project are presented. The power source developed is to be used for electric arc welding processes in which 3.5 trillion Btu of energy (1978 example year) can be saved annually. The power source development incorporates the use of switch mode power supply techniques in order to convert industrial supply mains (230/460 VAC 3 phi 60 Hz) to appropriate welding voltages and currents (up to 32 volts/up to 300 amps). A series capacitor switch mode power circuit was the circuit technique chosen in order to optimize energy efficiency, costs, reliability, size/weight, and welding performance. Test results demonstrated an effective efficiency (taking into account idle power consumption) of 80 to 91% for the energy efficient power source while the conventional types of power sources tested ranged from 41 to 74% efficiency. Line power factor was also improved for the energy efficient power source. Field tests indicated additional refinements of weld process performance and power source audible noise emission reduction could be beneficial.

  8. Design and testing of 45 kV, 50 kHz pulse power supply for dielectric barrier discharges.

    Science.gov (United States)

    Sharma, Surender Kumar; Shyam, Anurag

    2016-10-01

    The design, construction, and testing of high frequency, high voltage pulse power supply are reported. The purpose of the power supply is to generate dielectric barrier discharges for industrial applications. The power supply is compact and has the advantage of low cost, over current protection, and convenient control for voltage and frequency selection. The power supply can generate high voltage pulses of up to 45 kV at the repetitive frequency range of 1 kHz-50 kHz with 1.2 kW input power. The output current of the power supply is limited to 500 mA. The pulse rise time and fall time are less than 2 μs and the pulse width is 2 μs. The power supply is short circuit proof and can withstand variable plasma load conditions. The power supply mainly consists of a half bridge series resonant converter to charge an intermediate capacitor, which discharges through a step-up transformer at high frequency to generate high voltage pulses. Semiconductor switches and amorphous cores are used for power modulation at higher frequencies. The power supply is tested with quartz tube dielectric barrier discharge load and worked stably. The design details and the performance of the power supply on no load and dielectric barrier discharge load are presented.

  9. Analyzing the thermal regime of power supply units in portable betatrons by using infrared thermography

    Directory of Open Access Journals (Sweden)

    Simonova O.S.

    2017-01-01

    Full Text Available Potentials of infrared thermography in analyzing a thermal regime of the 7.5 MeV betatron power supply are discussed. Both the heating rate and thermal inertia of particular electronic components have been evaluated by processing pixel-based temperature histories. The data treatment has been performed by using the original ThermoFit Pro software to illustrate that some advanced processing algorithms, such as the Fourier transform and principle component analysis, are valuable in identifying thermal dynamics of particular power supply parts.

  10. Power supply projects a collection of innovative and practical design projects

    CERN Document Server

    Maplin

    1996-01-01

    Using circuit diagrams, PCB layouts, parts lists and clear construction and installation details, this book provides everything someone with a basic knowledge of electronics needs to know in order to put that knowledge into practice.This latest collection of Maplin projects are a variety of power supply projects, the necessary components for which are readily available from the Maplin catalogue or any of their high street shops. Projects include, laboratory power supply projects for which there are a wide range of applications for the hobbyist, from servicing portable audio and video equipment

  11. Replacement of Magnet Power Supplies, Control and Field-Bus for the Psi Cyclotron Accelerators

    OpenAIRE

    Anicic, D.; Blumer, T.; Dzieglewski, G.; Janser, G.; Jirousek, I.; Lutz, H; Mezger, A. C.

    2001-01-01

    Magnet power supplies in the PSI accelerator complex with their control and field-bus are old. Some components are more then 30 years old. To guarantee further maintenance and to meet the more demanding specifications for operation with the 2mA beam, they have to be replaced. The switched power supplies, developed for SLS, will be used. This implies a major redesign of part of the accelerator control system, which is now based on CAMAC, ROAD-C and other in house developed hardware including t...

  12. Transistor-based filter for inhibiting load noise from entering a power supply

    Science.gov (United States)

    Taubman, Matthew S

    2013-07-02

    A transistor-based filter for inhibiting load noise from entering a power supply is disclosed. The filter includes a first transistor having an emitter coupled to a power supply, a collector coupled to a load, and a base. The filter also includes a first capacitor coupled between the base of the first transistor and a ground terminal. The filter further includes an impedance coupled between the base and a node between the collector and the load, or a second transistor and second capacitor. The impedance can be a resistor or an inductor.

  13. Latin America: market mechanisms and supply adequacy in power sector reforms

    Energy Technology Data Exchange (ETDEWEB)

    Hammons, T.J. [University of Glasgow, Glasgow (United Kingdom); Barroso, L.A. [PSR, Rio de Janeiro (Brazil); Rudnick, H. [Pontificia Universidad Catolica de Chile, Santiago (Chile)

    2011-03-15

    The process of transformation in government and operations in the power sector leads to interaction between increasing integrated markets and public agencies in charge of policy making, regulation and control. This is examined for Latin America where state and marketing power sector planning, contract auctions to assure supply adequacy in an uncertain market environment, cross-border contracts, financing challenges for generation investments, and auctions of contracts to secure supply adequacy in the second stage of power sector reform are discussed. First, the state and market in power sector planning reform and state policies in Latin America are considered. Here, present concerns; the state-market relationship (the position of regulation, globalisation, internationalisation), and state market in the energy sector (correction and adjustments) are reviewed. Case studies for Argentina and Brazil are briefly outlined. The paper then examines contract auctions to assure supply adequacy in an uncertain energy environment that are being explored to face supply problems over recent years in the Chilean electricity market, taking into account the unexpected restrictions in natural gas transfers from Argentina. Also discussed are supply adequacy mechanisms and cross-border contracts in the Central American regional electricity market including firm transmission rights and financing challenges for generation investments. The final part of the paper discusses auctions of contracts and energy call options to ensure supply adequacy in the Brazilian power sector reform. Here, first stage of power sector reform, what went wrong, the second stage of reform and the move towards energy supply auctions, energy supply auctions so far and what's next in the challenges of environmental constraints and electricity-gas integration are reviewed. The reform being proposed to the electric regulatory framework for wholesale transactions in Peru is also reviewed. Considered are bids for

  14. The Hydraulic Mission and the Mexican Hydrocracy: Regulating and Reforming the Flows of Water and Power

    Directory of Open Access Journals (Sweden)

    Philippus Wester

    2009-10-01

    Full Text Available In Mexico, the hydraulic mission, the centralisation of water control, and the growth of the federal hydraulic bureaucracy (hydrocracy recursively shaped and reinforced each other during the 20th century. The hydraulic mission entails that the state, embodied in an autonomous hydrocracy, takes the lead in water resources development to capture as much water as possible for human uses. The hydraulic mission was central to the formation of Mexico’s hydrocracy, which highly prized its autonomy. Bureaucratic rivals, political transitions, and economic developments recurrently challenged the hydrocracy’s degree of autonomy. However, driven by the argument that a single water authority should regulate and control the nation’s waters, the hydrocracy consistently managed to renew its, always precarious, autonomy at different political moments in the country’s history. The legacy of the hydraulic mission continues to inform water reforms in Mexico, and largely explains the strong resilience of the Mexican hydrocracy to 'deep' institutional change and political transitions. While the emphasis on infrastructure has lessened, the hydrocracy has actively renewed its control over water decisions and budgets and has played a remarkably constant, hegemonic role in defining and shaping Mexico’s water laws, policies and institutions.

  15. Remote power supply by wind/diesel/battery systems - operational experience and economy

    Energy Technology Data Exchange (ETDEWEB)

    Kniehl, R. [CES - Consulting and Engineering Services, Heidelberg (Germany); Cramer, G.; Toenges, K.H. [SMA Regelsysteme GmbH, Niestetal (Germany)

    1995-12-31

    To continuously supply remote villages and settlements not connected to the public grid with electric power is an ambitious technical task considering ecological and economical points of view. The German company SMA has developed a modular supply system as a solution for this task in the range of 30 kW to 5 MW. Meanwhile more than 20 applications of these `Intelligent Power Systems (IPS)` have proved their technical reliability and economical competitiveness worldwide under different, and also extreme environmental conditions. Actually it is the first commercially available advanced Wind/Diesel/Battery System for remote area electrification. The modular autonomous electric supply systems realized by SMA basically consist of two or more diesel power sets, battery storage with converter, a rotating phaseshifter, and an optional number of wind turbines. All modules are coupled on the 3-phase AC system grid and run in various parallel configurations depending on the wind speed and the consumer power demand. The control system operates fully automatical and offers a very user-friendly graphical interface. This advanced system control also contains a remote control and operating data output via modem and telephone line. SMA and CES have considerable experience with Wind/Diesel/Battery Systems for more than eight years. In many cases wind energy converters in the power range of 30 to 40 kW were used, but it is also possible to use larger wind turbines (e.g. 250 kW). In the following the system technology is described in detail, experience of different system sizes in several countries of application is presented, and economical analyses for power supply by IPS are given in comparison to a conventional fully diesel power supply. (author)

  16. High-frequency power supply for making electro-resistance-welded tubes. Denhokanyo koshuha dengen

    Energy Technology Data Exchange (ETDEWEB)

    Konno, M. (Meidensha Corp., Tokyo (Japan))

    1991-12-27

    This paper introduces the current status of the Meidensha Corporation mainly on parts of a large-capacity electron-tube type high-frequency power supply for making electro-resistance-weld tubes (RFG). The company produces RFGs with oscillation output ranging from 65 to 1300 kW. The company uses oscillation tubes made by Nippon Electric Company for an oscillation output of 400 kW or lower, and those made by Siemens for above 400 kW. A water-cooled cylindrical capacitor, which has a unit capacity about five times as much of a disk type porcelain capacitor, enables constructing a compact tank circuit. The output from the oscillator driving power supply is adjusted by a thyristor AC control on the primary side of a positive transformer. The positive transformer (TF) adopts water cooling type for 100 kW or lower, and oil-filled self-cooling type for above 100 kW. The DC high-voltage power supply uses the power of the primary side of the positive TF which is controlled by a thyrisctor AC controller, and subjected to a three-face full-wave rectification using high-voltage silicon diodes. The oscillation tube, which operates on thermal electrons is heated to a prescribed temperature, of which value is controlled by the cathode heating power supply voltage. The voltage adjustment uses a constant voltage transformers system. 1 fig., 2 tabs.

  17. Transportation and dynamic networks: Models, theory, and applications to supply chains, electric power, and financial networks

    Science.gov (United States)

    Liu, Zugang

    Network systems, including transportation and logistic systems, electric power generation and distribution networks as well as financial networks, provide the critical infrastructure for the functioning of our societies and economies. The understanding of the dynamic behavior of such systems is also crucial to national security and prosperity. The identification of new connections between distinct network systems is the inspiration for the research in this dissertation. In particular, I answer two questions raised by Beckmann, McGuire, and Winsten (1956) and Copeland (1952) over half a century ago, which are, respectively, how are electric power flows related to transportation flows and does money flow like water or electricity? In addition, in this dissertation, I achieve the following: (1) I establish the relationships between transportation networks and three other classes of complex network systems: supply chain networks, electric power generation and transmission networks, and financial networks with intermediation. The establishment of such connections provides novel theoretical insights as well as new pricing mechanisms, and efficient computational methods. (2) I develop new modeling frameworks based on evolutionary variational inequality theory that capture the dynamics of such network systems in terms of the time-varying flows and incurred costs, prices, and, where applicable, profits. This dissertation studies the dynamics of such network systems by addressing both internal competition and/or cooperation, and external changes, such as varying costs and demands. (3) I focus, in depth, on electric power supply chains. By exploiting the relationships between transportation networks and electric power supply chains, I develop a large-scale network model that integrates electric power supply chains and fuel supply markets. The model captures both the economic transactions as well as the physical transmission constraints. The model is then applied to the New

  18. Sediment supply versus local hydraulic controls on sediment transport and storage in a river with large sediment loads

    Science.gov (United States)

    Dean, David; Topping, David; Schmidt, John C.; Griffiths, Ronald; Sabol, Thomas

    2016-01-01

    The Rio Grande in the Big Bend region of Texas, USA, and Chihuahua and Coahuila, Mexico, undergoes rapid geomorphic changes as a result of its large sediment supply and variable hydrology; thus, it is a useful natural laboratory to investigate the relative importance of flow strength and sediment supply in controlling alluvial channel change. We analyzed a suite of sediment transport and geomorphic data to determine the cumulative influence of different flood types on changing channel form. In this study, physically based analyses suggest that channel change in the Rio Grande is controlled by both changes in flow strength and sediment supply over different spatial and temporal scales. Channel narrowing is primarily caused by substantial deposition of sediment supplied to the Rio Grande during tributary-sourced flash floods. Tributary floods have large suspended-sediment concentrations, occur for short durations, and attenuate rapidly downstream in the Rio Grande, depositing much of their sediment in downstream reaches. Long-duration floods on the mainstem have the capacity to enlarge the Rio Grande, and these floods, released from upstream dams, can either erode or deposit sediment in the Rio Grande depending upon the antecedent in-channel sediment supply and the magnitude and duration of the flood. Geomorphic and sediment transport analyses show that the locations and rates of sand erosion and deposition during long-duration floods are most strongly controlled by spatial changes in flow strength, largely through changes in channel slope. However, spatial differences in the in-channel sediment supply regulate sediment evacuation or accumulation over time in long reaches (greater than a kilometer).

  19. Uninterruptible Power Supply Technologies and Proposal of Closed-Loop Power Supply in Chemical Industry%化工企业不间断电源技术简介及闭环回路供电的探讨

    Institute of Scientific and Technical Information of China (English)

    李建平

    2014-01-01

    Describe several uninterruptible power supply technologies which including dual power supply ,USB uninterruptible power supply ,TPM series no disturbance stability control device ,and propose the technology of closed‐loop supplying power for anti‐interference electricity .%论述化工企业几种不间断电源技术---双电源供电、 UPS 不间断电源、 TPM 系列无扰动稳定控制装置,并提出闭路回路供电抗晃电的设想。

  20. Historic of electric rail power supply in the Swiss Bernese Oberland; Geschichte der elektrischen Bahnenergieversorgung im schweizerischen Berner Oberland

    Energy Technology Data Exchange (ETDEWEB)

    Jampen, U. [BKW FMB Energie AG, Bern (Switzerland)

    2006-07-01

    With beginning of the railway electrification in the Bernese Oberland hundred years ago the first water power and converter stations were built for the railway power supply. At first separately operated the stations were integrated in an connected network later. Today these stations are a part of the whole railway power supply in Switzerland. (orig.)

  1. 14 CFR 121.645 - Fuel supply: Turbine-engine powered airplanes, other than turbo propeller: Flag and supplemental...

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Fuel supply: Turbine-engine powered... SUPPLEMENTAL OPERATIONS Dispatching and Flight Release Rules § 121.645 Fuel supply: Turbine-engine powered... Columbia with a turbine engine powered airplane the fuel requirements of § 121.643 apply....

  2. A High Voltage Power Supply That Mitigates Current Reversals in Capillary Zone Electrophoresis-Electrospray Mass Spectrometry

    Science.gov (United States)

    Flaherty, Ryan J.; Sarver, Scott A.; Sun, Liangliang; Brownell, Greg A.; Go, David B.; Dovichi, Norman J.

    2017-02-01

    Capillary electrophoresis coupled with electrospray ionization typically employs two power supplies, one at each end of the capillary. One power supply is located at the proximal (injection) end of the capillary. The power supply located at the distal (detector) end of the capillary drives the electrospray. Electrophoresis is driven by the difference in potential between these power supplies. Separations that employ large capillary inner diameter, high conductivity background electrolyte, and high separation potentials generate higher current than that produced by the electrospray. Excess current flows through the electrospray power supply. Most power supplies are not designed to sink current, and the excess current will cause the electrospray voltage to deviate from its set point. We report a simple circuit to handle this excess current, allowing separations under a wide range of electrophoretic conditions.

  3. Report on emergency electrical power supply systems for nuclear fuel cycle and reactor facilities security systems

    Energy Technology Data Exchange (ETDEWEB)

    1977-01-01

    The report includes information that will be useful to those responsible for the planning, design and implementation of emergency electric power systems for physical security and special nuclear materials accountability systems. Basic considerations for establishing the system requirements for emergency electric power for security and accountability operations are presented. Methods of supplying emergency power that are available at present and methods predicted to be available in the future are discussed. The characteristics of capacity, cost, safety, reliability and environmental and physical facility considerations of emergency electric power techniques are presented. The report includes basic considerations for the development of a system concept and the preparation of a detailed system design.

  4. Design of the klystron filament power supply control system for EAST LHCD

    Science.gov (United States)

    Wu, Zege; Wang, Mao; Hu, Huaichuan; Ma, Wendong; Zhou, Taian; Zhou, Faxin; Liu, Fukun; Shan, Jiafang

    2016-09-01

    A filament is a critical component of the klystron used to heat the cathode. There are totally 44 klystrons in experimental advanced superconducting tokamak (EAST) lower hybrid current drive (LHCD) systems. All klystron filaments are powered by AC power suppliers through isolated transformers. In order to achieve better klystron preheat, a klystron filament power supply control system is designed to obtain the automatic control of all filament power suppliers. Klystron filament current is measured by PLC and the interlock between filament current and klystron high voltage system is also implemented. This design has already been deployed in two LHCD systems and proves feasible completely.

  5. Design of the klystron filament power supply control system for EAST LHCD

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Zege; Wang, Mao; Hu, Huaichuan; Ma, Wendong; Zhou, Taian; Zhou, Faxin; Liu, Fukun; Shan, Jiafang [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China)

    2016-09-15

    A filament is a critical component of the klystron used to heat the cathode. There are totally 44 klystrons in experimental advanced superconducting tokamak (EAST) lower hybrid current drive (LHCD) systems. All klystron filaments are powered by AC power suppliers through isolated transformers. In order to achieve better klystron preheat, a klystron filament power supply control system is designed to obtain the automatic control of all filament power suppliers. Klystron filament current is measured by PLC and the interlock between filament current and klystron high voltage system is also implemented. This design has already been deployed in two LHCD systems and proves feasible completely.

  6. THREE-PHASE ENERGY SUPPLY SYSTEMS SIMULATION FOR THE TOTAL POWER LOSSES COMPONENTS ASSESSMENT

    Directory of Open Access Journals (Sweden)

    D.V. Tugay

    2016-09-01

    Full Text Available Purpose. The goal is to optimize a structure of Matlab-model of the three-phase energy supply system with power active filter. The mathematical model that describes the energy supply system modes of operation which contains additional losses is proposed. Methodology. We have applied concepts of the electrical circuits theory, mathematical modeling elements based on linear algebra and vector calculus, mathematical simulation in Matlab package. Results. We have developed two models of three-phase energy supply system. The first one is based on a vector representation, and the second one on the matrix representation of energy processes. Using these models we have solved the problem of maintaining unchanged the average useful power for 279 cases of energy supply system modes of operation. Originality. We have developed methods of mathematical analysis of a three-phase energy supply systems with polyharmonic voltages and currents in the symmetric and asymmetric modes. Practical value. We have created Matlab-model of a three-phase energy supply system with automated calculation of a correction factor. It allows reducing more than one order the time for energy processes elucidation in multiphase systems.

  7. Assessment of two-level heat pump installations’ power efficiency for heat supply systems

    Directory of Open Access Journals (Sweden)

    Аlla Е. Denysova

    2015-06-01

    Full Text Available The problem of energy saving becomes one of the most important in power engineering. It is caused by exhaustion of world reserves in hydrocarbon fuel, such as gas, oil and coal representing sources of traditional heat supply. Conventional sources has essential shortcomings: low power, ecological and economic efficiencies, that can be eliminated by using alternative methods of power supply, like the considered one: low-temperature natural heat of ground waters of on the basis of heat pump installations application. The heat supply system considered provides an effective use of two-level heat pump installation operating as heat source the Odessa city ground waters during the lowest ambient temperature period. Proposed is a calculation method of heat pump installations on the basis of geothermal heat supply. Calculated are the values of electric energy consumption N by the compressors’ drive, and the heat supply system transformation coefficient µ for a source of geothermal heat from ground waters of Odessa city allowing to estimate efficiency of two-level heat pump installations.

  8. Efficiency Enhancement of an Envelope Tracking Power Amplifier Combining Supply Shaping and Dynamic Biasing

    DEFF Research Database (Denmark)

    Tafuri, Felice Francesco; Sira, Daniel; Jensen, Ole Kiel

    2013-01-01

    This paper presents a new method to improve the performance of envelope tracking (ET) power amplifiers (PAs). The method consists of combining the supply modulation that characterizes the envelope tracking architecture with supply shaping and dynamic biasing. The inclusion of dynamic biasing allows...... of the input envelope by means of two shaping functions jointly designed on the basis of a single-tone characterization. The presented technique is demonstrated by means of measurements on a commercial GaAs HBT power amplifier. Measured results showed a PA power added efficiency (PAE) of 51.9%, an error vector...... magnitude (EVM) of 1.2% and an adjacent channel power ratio (ACPR) of -39.4/-43.5 dBc. The presented transmitter architecture allowed an improvement of 12% PAE compared to a classical ET transmitter where the measured PA was biased in class-AB, maintaining the linearity indicators....

  9. Virtual instrument for controlling and monitoring digitalized power supply in SSRF

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The Shanghai Synchrotron Radiation Facility (SSRF) needs extremely precise power supplies for their various magnets. A digital controller is being developed for the power converters of the SSRF power supply (PS). In the digital controller, a fully digital pulse-width modulator (PWM) directly controls the power unit insulated gate bipolar transistor (IGBT) of the PS. A program in LabVIEW language has been developed to control and monitor the digital PS via serial communication (RS232) from a PC and to modify its parameters as well. In this article, the software design of the virtual instrument for controlling and monitoring digitalized PS and its associated functions are described, and the essential elements of the program graphical main-Ⅵ and sub-Ⅵ source code are presented and explained. The communication protocol and the structure of the developed system are also included in this article.

  10. TO THE SUBJECT OF DEVELOPMENT OF POWER SUPPLY PROCESS FOR INDUSTRIAL HEAT TECHNOLOGIES AND HEAT SUPPLY SYSTEMS IN BELARUS

    Directory of Open Access Journals (Sweden)

    B. M. Khrоustalev

    2014-01-01

    Full Text Available Considers the current key energy problem – the rational and efficient use of energy resources, and the possibility of its solution, based on the concept of intensive energy conservation. As a result, the way of primary energy consumption reduction in Belarus is provided. The initial situation in the frame of program of further improvement of energy consumption until 2030 is estimated. It is shown, that for Belarus the first place in energy saving measures takes the efficiency improvement of natural gas consumption, what allows reducing the investment and saving energy resources.The possibility of usage of waste energy flows of medium-and low-temperature from industrial and municipal enterprises are discussed. To realize the described possibilities, some changes of heat supply system of enterprises and plants are required. Changes in heat supply system of the industrial enterprises, related with usage of low-temperature waste energy flows in a thermal energy generation process for heating, require the installation of additional equipment in existing heat energy supply system, such as absorption heat pumps, which are easily joint and successfully work at boiler Houses as well as at CHP. The numerous examples of fuel consumption reduction via heat industrial waste and sewage usage are shown in this article. It must be emphasized, that such an expansion of energy-saving framework not only reduce the primary energy consumption by heat generating sources, but also significantly improves the conditions of the Belarusian electrical grid operation under the conditions of nuclear power plant commissioning. The existing technical framework, that ensured the proposed changes, is also taking into account.

  11. U.S. SOCOM Grand Challenge #3: NREL Technical Roadmap for a Man-Portable Power Supply System for TALOS

    Energy Technology Data Exchange (ETDEWEB)

    Ainsworth, Nathan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Heaps, Colton [National Renewable Energy Lab. (NREL), Golden, CO (United States); Symko-Davies, Martha [National Renewable Energy Lab. (NREL), Golden, CO (United States); Cale, James [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-06-01

    The purpose of this report is to propose a technical roadmap for power supply technology to power the Tactical Assault Light Operator Suit (TALOS), an armored, powered exoskeleton currently in development for U.S. Special Operations Command operators. TALOS' power supply system must meet size targets similar to the size of a large backpack while providing significant electrical power for an entire mission cycle without resupply. This report proposes a staged development path based on three fundamental technical approaches.

  12. Characterization of a pulsed mode high voltage power supply for nuclear detectors

    Science.gov (United States)

    Ghazali, A. B.; Ahmad, T. S.; Abdullah, N. A.

    2013-06-01

    This paper discusses the characterization of a pulsed mode high voltage power supply (HVPS) using LT1073 chip. The pulsed modulated signal generated from this chip is amplified using a step-up ferrite core transformer of 1:20 turn ratio and then further multiplied and converted into DC high voltage output using a diode-capacitor arrangement. The circuit is powered by a 9V alkaline battery but regulated at 5V supply. It was found that the output for this setup is 520V, 87 μA with 10% load regulation. This output is suitable to operate a pancake-type GM detector, typically model LND 7317 where the plateau is from 475V to 675V. It was also found that when a β-source with intensity of 120 cps is used, the power consumption of the circuit is 5 V, 10.1 mA only. When the battery was left 'on' for 40 hours continuously, the battery's voltage has dropped to 6.9V, meaning that the 5V supply as well as 520V output is still maintained. It is noted that the minimum output voltage of 475V has reached when the regulated supply has reduced to 4.6V and consequently the 9V battery dropped to 6.5V, and this had happened after approximately 3 days of continuous operation. The power efficiency for this circuitry was found to be 89.5%. This result has far better in performance since the commercial portable equipment of this type has normally specified that not less than 8 hours continuous operation only. On the circuit design for this power supply, it was found that the enveloped frequency is 133 Hz with approximately 50% duty cycle. The modulated frequency during 'on' state was found to be 256 KHz in which the majority of power consumption is required.

  13. Improving the Reliability of LDP through the Divergence of Power Supply for LDP

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Bang Sil [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    The representative operating systems are Large Display Panel (LDP), Operator Workstation (OWS), Computerized Procedure System (CPS). The LDP provides the information which is plant essential safety function, plant operating mode, the state of major operating variable and the important alarm to operator continuously. In case of malfunction and switchover fail of the inverter, it is possible to occur the power loss of LDP. The power of LDP and operator console workstation had been supplied by only 2 non-safety Power Line1/Power Line2 (P.L1/P.L2). This study mentioned the divergence of power for LDP as method of power loss caused by unreliability of inverter. Ultimately, LDP power line has been added, and then it is more improved on the safety of LDP operation than before. So Shin-Kori 3,4 can enhance the reliability and economic, safety of plant.

  14. Power Supply Reliability Assessment in UPFC-installed Transmission System for ATC Enhancement Considering Transient Stability

    Science.gov (United States)

    Masuta, Taisuke; Yokoyama, Akihiko

    With recent development of power electronics technology, power system stability enhancement and optimal power flow control by using Flexible AC Transmission System (FACTS) devices have so far been studied. The FACTS devices to relieve multiple constraints can also make it possible to enhance Available Transfer Capability (ATC) without construction of new transmission lines. The previous research revealed that ATC is expanded by avoiding multiple constraints in OPF using Unified Power Flow Controller (UPFC). For long-term operation of such ATC-expanded power system, it is necessary to evaluate power system reliability. In this paper, the evaluation method of supply reliability for UPFC-installed power system is proposed. Both thermal capacity and transient stability constraints are considered. The effectiveness of the proposed method is shown by numerical examples for IEEJ East10-machine test system.

  15. ENSURING THERMAL REGIME FOR THE SUPPLY DISTRIBUTED DEVICES IN THE COMPOSITION OF THE SHIP'S SECONDARY POWER SUPPLY SYSTEMS ON THE BASE OF THE STANDARDIZED UNITS

    Directory of Open Access Journals (Sweden)

    T. A. Ismailov

    2016-01-01

    Full Text Available Aim. The article deals with the problem of constructing the power supply devices in the composition of the ship's secondary power systems based on standardized blocks and securing their thermal regime.Methods. It is stated that with the advent of modern power electronics multifunctional components the secondary power supply developers got possibilities to improve the quality of secondary power supply and to upgrade the existing systems.Results. The advantages of unified power units, having a function of parallel operation are revealed. Heat transfer processes in a vertical channel with free convection, and the calculation of the minimum width of the channel, which provides efficient heat removal have been analyzed.Conclusion.A model is proposed for determining the minimum distance between the blocks without deterioration of heat transfer in the channel formed by the walls of adjacent blocks.

  16. Traction power supply for the Schwerin tramway network; Bahnenergieversorgung der Schweriner Strassenbahn

    Energy Technology Data Exchange (ETDEWEB)

    Fronzke, Hans-Joachim [Elpro BahnstromAnlagen GmbH, Berlin (Germany). EBA-T; Maack, Andreas [Nahverkehr Schwerin GmbH, Schwerin (Germany); Schumann, Frank [ELBAS Elektrische Bahnsysteme Ingenieur-Gesellschaft mbH, Berlin (Germany)

    2011-12-15

    Since the middle of the 1990s, the complete power supply system for the Schwerin tramway has been under reconstruction with the aim to allow new tramway vehicles to be used without power limitation and in an energetically optimised manner. This reconstruction includes the step-by-step installation of a new catenary system and the reconstruction of all substations, together with a general conversion from single to dual feeding. (orig.)

  17. Study of the Power Supply Ripple Effect on teh Dynamics at SPEAR

    Energy Technology Data Exchange (ETDEWEB)

    Terebilo, A.; Pellegrini, C.; /UCLA; Cornacchia, M.; Corbett, J.; Martin, D.; /SLAC

    2011-09-14

    For long term stability analysis time variation of tunes is important. We have proposed and tested a technique for measuring the magnitude of this variation. This was made possible by using tune extraction algorithms that require small number of turns thus giving an instantaneous tune of the machine. In this paper we demonstrate the measured effect of the tune modulation with 60 Hz power supplies ripple, power line interference from SLAC linac operating at 30 Hz repetition rate, and nonperiodic variation.

  18. Security Vulnerability Trends Related to Electric Power Supplied at Military Installations

    Science.gov (United States)

    2010-03-01

    becoming increasingly worried about the possible negative effects due to solar flares from the sun. A severe solar flare has the possibility to not...as the power system will be continuously tested by hurricanes, tornadoes, earthquakes , and various weather events; additionally, scientists are also...different components necessary to supply coal to power plants and analyzed how an earthquake can have far-reaching effects. In fact, this study

  19. Design of a Percussion and Electric Primer Gun Firing Power Supply

    Science.gov (United States)

    2014-07-01

    to drive a solenoid into a percussion primer or ignite the M52A3B1 electric primer. To reduce power requirements, it uses charged capacitor banks to...gun, percussion, electric primer, capacitor 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT UU 18. NUMBER OF PAGES 30 19a. NAME...initial pull of the solenoid, which can be over 50 A. The old linear power supply has large filter capacitors on its output, which does provide the surge

  20. Power supply for the Spanish stellarator TJ-II, design, construction, and tests

    Energy Technology Data Exchange (ETDEWEB)

    Perez, A.; Lucia, C.; Alberdi, B.; Del Rio, J.M. [JEMA SA, Lasarte-Oria (Spain); Almoguera, L.; Blaumoser, M.; Kirpitchev, I.; Mendez, P. [Asociacion EURATOM-CIEMAT para Fusion, Madrid (Spain)

    1995-12-31

    Most of the components of the electrical power supply system of the new TJ-II stellarator, which is under construction in Madrid (Spain), are now constructed and tested. The flywheel synchronous generator is still under construction and its tests are planned for the end of 1995. The power plant is described in detail as well as the tests which have been carried out and their results.

  1. Water constraints on European power supply under climate change: Impacts on electricity prices

    OpenAIRE

    Michelle T.H. van Vliet; Vögele, Stefan; Rübbelke, Dirk

    2013-01-01

    Recent warm, dry summers showed the vulnerability of the European power sector to low water availability and high river temperatures. Climate change is likely to impact electricity supply, in terms of both water availabilty for hydropower generation and cooling water usage for thermoelectric power production. Here, we show the impacts of climate change and changes in water availability and water temperature on European electricity production and prices. Using simulations of daily river flo...

  2. Environmental concerns and regulatory initiatives related to hydraulic fracturing in shale gas formations: potential implications for North American gas supply

    Energy Technology Data Exchange (ETDEWEB)

    Sumi, Lisa [Earthworks (Canada)

    2010-09-15

    Shale gas resources have been referred to as a game changer for North America and it is expected that shale gas will account for over 30% of the natural gas production in North America by 2020. However, the development of this resource has raised several concerns, notably in terms of water use and contamination; more stringent regulations could be implemented in the coming years. The aim of this paper is to present the effect that more stringent regulations would have on gas development in the Marcellus shale, which accounts for 20% of North American shale gas production. Information on hydraulic fracturing and its environmental impacts is provided herein, along with information on the regulatory initiatives underway in the Marcellus shale region. This paper pointed out that novel regulations relating to shale gas development could significantly reduce the growth in shale gas production.

  3. Cost analysis of concepts for a demand oriented biogas supply for flexible power generation.

    Science.gov (United States)

    Hahn, Henning; Ganagin, Waldemar; Hartmann, Kilian; Wachendorf, Michael

    2014-10-01

    With the share of intermittent renewable energies within the electricity system rising, balancing services from dispatchable power plants are of increasing importance. Highlighting the importance of the need to keeping fuel costs for flexible power generation to a minimum, the study aims to identify favourable biogas plant configurations, supplying biogas on demand. A cost analysis of five configurations based on biogas storing and flexible biogas production concepts has been carried out. Results show that additional flexibility costs for a biogas supply of 8h per day range between 2€ and 11€MWh(-1) and for a 72h period without biogas demand from 9€ to 19€MWh(-1). While biogas storage concepts were identified as favourable short term supply configurations, flexible biogas production concepts profit from reduced storage requirements at plants with large biogas production capacities or for periods of several hours without biogas demand.

  4. Design and analysis of power supply and information transfer to three-axis gyroscope stabilizer platform

    Directory of Open Access Journals (Sweden)

    Belyanin Lev

    2016-01-01

    Full Text Available The paper focuses on problems of the engineering implementation of 3-axis gyrostabilizer of the camera for orthophotography performed from light and ultralight aircrafts. The functional diagram of gyrostabilizer is characterized by a lighter ball-bearing having a large inner diameter used for the platform suspension on its internal (vertical axis. The problem is to transfer the supply voltage to the platform and the electric signals to and from the platform. Design solutions concerning the power supply and information transfer are supported by the experimental techniques suggested in this paper, namely: the use of the rolling contact; three-phase gyro motor power supply replaced by that from the single-phase network; signal transmission from the precession angle sensor using the air transformer; current and voltage frequency division; DC mode selection for the torquer. The results obtained prove the efficiency of the suggested design solutions.

  5. Contrasting Electricity Demand with Wind Power Supply: Case Study in Hungary

    Directory of Open Access Journals (Sweden)

    Imre M. Jánosi

    2009-09-01

    Full Text Available We compare the demand of a large electricity consumer with supply given by wind farms installed at two distant geographic locations. Obviously such situation is rather unrealistic, however our main goal is a quantitative characterization of the intermittency of wind electricity. The consumption pattern consists of marked daily and weekly cycles interrupted by periods of holidays. In contrast, wind electricity production has neither short-time nor seasonal periodicities. We show that wind power integration over a restricted area cannot provide a stable baseload supply, independently of the excess capacity. Further essential result is that the statistics are almost identical for a weekly periodic pattern of consumption and a constant load of the same average value. The length of both adequate supply and shortfall intervals exhibits a scale-free (power-law frequency distribution, possible consequences are shortly discussed.

  6. Power and culture in supply chains: contributions of the strategic action fields approach

    Directory of Open Access Journals (Sweden)

    Silvio Eduardo Alvarez Candido

    Full Text Available Abstract Important research efforts have been developed to account for power in the analysis of supply chains. This paper argues that further gains may arise by considering organizations as social constructions mediated not only by power relations, but also by cultural representations intrinsically intertwined to it. Its purpose is to discuss the dynamics of stability and change in supply chains based on the Strategic Action Fields (SAFs approach. A theoretical essay was elaborated discussing some of the main implications of this perspective to the study of supply chains and presenting propositions to enable the construction of research objects and guide empirical studies in the area. Propositions emphasize how ongoing cultural-political relations circumscribed to different fields, including the organization, with its internal disputes.

  7. Effect of voltage shape of electrical power supply on radiation and density of a cold atmospheric argon plasma jet

    National Research Council Canada - National Science Library

    F Sohbatzadeh; M Bagheri; S Motallebi

    2017-01-01

    In this work, we investigated generating argon cold plasma jet at atmospheric pressure based on dielectric barrier discharge configuration using three electrical power supplies of sinusoidal, pulsed...

  8. Design and Application of a Power Unit to Use Plug-In Electric Vehicles as an Uninterruptible Power Supply

    Directory of Open Access Journals (Sweden)

    Gorkem Sen

    2016-03-01

    Full Text Available Grid-enabled vehicles (GEVs such as plug-in electric vehicles present environmental and energy sustainability advantages compared to conventional vehicles. GEV runs solely on power generated by its own battery group, which supplies power to its electric motor. This battery group can be charged from external electric sources. Nowadays, the interaction of GEV with the power grid is unidirectional by the charging process. However, GEV can be operated bi-directionally by modifying its power unit. In such operating conditions, GEV can operate as an uninterruptible power supply (UPS and satisfy a portion or the total energy demand of the consumption center independent from utility grid, which is known as vehicle-to-home (V2H. In this paper, a power unit is developed for GEVs in the laboratory to conduct simulation and experimental studies to test the performance of GEVs as a UPS unit in V2H mode at the time of need. The activation and deactivation of the power unit and islanding protection unit are examined when energy is interrupted.

  9. Pulsed power supply for Nova Upgrade. Final report, August 1, 1991 to March 31, 1992

    Energy Technology Data Exchange (ETDEWEB)

    Bacon, J.L.; Kajs, J.P.; Walls, A.; Weldon, W.F.; Zowarka, R.C. [Univ. of Texas, Austin, TX (US). Center for Electromechanics

    1992-12-31

    This report describes work carried out at the Center for Electromechanics at The University of Texas at Austin (CEM-UT). A baseline design of the Nova Upgrade has been completed by Lawrence Livermore National Laboratory. The Nova Upgrade is an 18 beamline Nd: glass laser design utilizing fully relayed 4x4 30 cm aperture segmented optical components. The laser thus consists of 288 independent beamlets nominally producing 1.5 to 2.0 MJ of 0.35 {mu}m light in a 3 to 5 ns pulse. The laser design is extremely flexible and will allow a wide range of pulses to irradiate ICF targets. This facility will demonstrate ignition/gain and the scientific feasibility of ICF for energy and defense applications. The pulsed power requirements for the Nova Upgrade are given. CEM-UT was contracted to study and develop a design for a homopolar generator/inductor (HPG/inductor) opening switch system which would satisfy the pulsed power supply requirements of the Nova Upgrade. The Nd:glass laser amplifiers used in the Nova Upgrade will be powered by light from xenon flashlamps. The pulsed power supply for the Nova Upgrade powers the xenon flashlamps. This design and study was for a power supply to drive flashlamps.

  10. Performance Analyses of Renewable and Fuel Power Supply Systems for Different Base Station Sites

    Directory of Open Access Journals (Sweden)

    Josip Lorincz

    2014-11-01

    Full Text Available Base station sites (BSSs powered with renewable energy sources have gained the attention of cellular operators during the last few years. This is because such “green” BSSs impose significant reductions in the operational expenditures (OPEX of telecom operators due to the possibility of on-site renewable energy harvesting. In this paper, the green BSSs power supply system parameters detected through remote and centralized real time sensing are presented. An implemented sensing system based on a wireless sensor network enables reliable collection and post-processing analyses of many parameters, such as: total charging/discharging current of power supply system, battery voltage and temperature, wind speed, etc. As an example, yearly sensing results for three different BSS configurations powered by solar and/or wind energy are discussed in terms of renewable energy supply (RES system performance. In the case of powering those BSS with standalone systems based on a fuel generator, the fuel consumption models expressing interdependence among the generator load and fuel consumption are proposed. This has allowed energy-efficiency comparison of the fuel powered and RES systems, which is presented in terms of the OPEX and carbon dioxide (CO2 reductions. Additionally, approaches based on different BSS air-conditioning systems and the on/off regulation of a daily fuel generator activity are proposed and validated in terms of energy and capital expenditure (CAPEX savings.

  11. A combined uninterruptible power supply and dynamic voltage compensator using a flywheel energy storage system

    Science.gov (United States)

    Weissbach, Robert Stephen

    Due to recent technological advances in materials, power electronics, magnetic bearings and controls, the flywheel energy storage system has become a viable alternative to electrochemical batteries. The advantages of the flywheel system are its higher power density, insensitivity to environmental conditions, lack of hazardous materials and ease of checking the charge. One potential use is in a power distribution system. The flywheel energy storage system may be used as both an uninterruptible power supply as well as a means of dynamic voltage compensation to protect critical loads on radial distribution feeders. To perform dynamic voltage compensation, a comparison was performed which shows that the series injection of power is preferable to the shunt injection of power in utilizing the available kVA of the flywheel system motor/generator. The system was designed and modeled using the Electromagnetic Transients Program to ensure a proper dynamic response of the flywheel energy storage system in either mode of operation. The design incorporates a boost converter on the dc link to enable the load voltage to be maintained as the flywheel spins down. The same boost converter also allows for extended operation in the series compensation mode, by implementing a novel control scheme where sinusoidal pulse width modulation control is used for to compensate for smaller supply voltage dips, while the boost converter is used to control the compensation for larger supply voltage dips.

  12. Influence of Frequency Converters on Insulation of Power Supply Cables at Oil-Producing Stations

    Directory of Open Access Journals (Sweden)

    D. I. Zalizny

    2011-01-01

    Full Text Available The paper considers consequences of negative frequency converter influence on insulation of  power supply cables used for submersible installations of electric-centrifugal pumps at oil-producing stations. The possible approaches to the solution of the problem are proposed on the basis of a harmonic analysis of actually measured voltages and currents in a cable.  

  13. Bargaining power and revenue distribution in the Costa Rican mango supply chain

    NARCIS (Netherlands)

    Zúñiga-Arias, G.; Meijer, S.A.; Ruben, R.; Hofstede, G.J.

    2007-01-01

    By the time a European consumer eats a Costa Rican mango, the product has been traded in several transactions between producers, traders, retailers and consumers. This paper investigates the position of Costa Rican smallholders in the mango supply chain in terms of bargaining power and revenue

  14. 7 CFR 1710.252 - Construction work plans-power supply borrowers.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 11 2010-01-01 2010-01-01 false Construction work plans-power supply borrowers. 1710... LOANS AND GUARANTEES Construction Work Plans and Related Studies § 1710.252 Construction work plans..., environmental and other studies and plans needed to support the construction of facilities, when such cost...

  15. Solar power supply to the public grid; Die Einspeisung von Solarstrom ins Netz

    Energy Technology Data Exchange (ETDEWEB)

    Seltmann, T.

    1998-03-01

    Current inverters for grid-connected solar power systems are gaining increasing importance. An outline of grid supply concepts and markets shows a wide variety. (orig.) [Deutsch] Wechselrichter fuer netzgekoppelte Solarstromanlagen gewinnen an Bedeutung. Ein aktueller Ueberblick ueber die Konzepte der Netzeinspeisung und den Markt zeigt eine erstaunlich grosse Vielfalt. (orig.)

  16. Standard for decentralized power supply to the public grid; Norm fuer dezentrale Netzeinspeisung

    Energy Technology Data Exchange (ETDEWEB)

    Seltmann, T. [SolarAgentur, Nuernberg (Germany); Kremer, P. [Siemens AG, Fuerth (Germany); Lappe, U. [Berufsgenossenschaft der Feinmechanik und Elektrotechnik, Koeln (Germany). Abt. Sicherheitsfragen der Elektrotechnik

    1999-08-01

    Photovoltaic energy conversion has finally been acknowledged in technical specifications. The new DIN VDE 0126 regulates decentralized power supply to the publc grid and improves protection of working staff. [German] Die photovoltaische Stromerzeugung haelt jetzt auch Einzug in technische Regelwerke. Die kuerzlich in Kraft getretene DIN VDE 0126 macht den Weg frei fuer die flaechendeckende dezentrale Netzeinspeisung. Ausserdem verbessert diese Norm den Personenschutz. (orig.)

  17. A combined noise analysis and power supply current based testing of CMOS analog integrated circuits

    Science.gov (United States)

    Srivastava, Ashok; Pulendra, Vani K.; Yellampalli, Siva

    2005-05-01

    A technique integrating the noise analysis based testing and the conventional power supply current testing of CMOS analog integrated circuits is presented for bridging type faults due to manufacturing defects. The circuit under test (CUT) is a CMOS amplifier designed for operation at +/- 2.5 V and implemented in 1.5 μm CMOS process. The faults simulating possible manufacturing defects have been introduced using the fault injection transistors. The amplifier circuit is analyzed and simulated in SPICE for its performance with and without fault injections. The faults in the CUT are identified by observing the variation in the equivalent noise voltage at the output of CUT. In power supply current testing, the current (IPS) through the power supply voltage, VDD is measured under the application of an AC input stimulus. The effect of parametric variation is taken into consideration by determining the tolerance limit using the Monte-Carlo analysis. The fault is identified if the power supply current, IPS lies outside the deviation given by Monte-Carlo analysis. Simulation results are in close agreement with the corresponding experimental values.

  18. FERMI magnet power supplies: design strategies and five years of operational experience

    Science.gov (United States)

    Visintini, Roberto

    2015-05-01

    FERMI is the FEL-based light source in operation for external users since 2011 at the Elettra Research Center in Trieste, Italy. FERMI@Elettra is the name of the project for the construction and commissioning of this source. The design strategies adopted in the project had to consider the extremely close presence and the routine operation for users of the synchrotron-based source Elettra. There are more than 350 magnets and coils distributed along the linear accelerator, the two chains of undulators and the electron beam dump. Almost each magnetic element requires a dedicated DC power supply. Magnets, power supplies, and the connecting cables constitute a system, strongly interconnected with the remote control system, the machine and personnel safety system, and the infrastructure. All this has to fulfill the requirements from the particle physics specialists. We adopted a "systemic" approach in the design of new magnets and the re-use of the old ones, as well as the choice and the design of the associated power supplies. The commissioning of the systems started early 2010 and almost all magnet power supplies are in operation since then. During these 5 years, we introduced few minor upgrades and patches while the adopted solutions proved their soundness in terms of performance and reliability, causing very little downtime to the FERMI operations.

  19. Effect of voltage sags on digitally controlled line connected switched-mode power supplies

    DEFF Research Database (Denmark)

    Török, Lajos; Munk-Nielsen, Stig

    2012-01-01

    Different voltage disorders like voltage fluctuations, sags, frequency variations may occur in the power supply networks due to different fault conditions. These deviations from normal operation affects in different ways the line connected devices. Standards were developed to protect and ensure i...

  20. A Power-Efficient Wireless System With Adaptive Supply Control for Deep Brain Stimulation

    Science.gov (United States)

    Lee, Hyung-Min; Park, Hangue; Ghovanloo, Maysam

    2014-01-01

    A power-efficient wireless stimulating system for a head-mounted deep brain stimulator (DBS) is presented. A new adaptive rectifier generates a variable DC supply voltage from a constant AC power carrier utilizing phase control feedback, while achieving high AC-DC power conversion efficiency (PCE) through active synchronous switching. A current-controlled stimulator adopts closed-loop supply control to automatically adjust the stimulation compliance voltage by detecting stimulation site potentials through a voltage readout channel, and improve the stimulation efficiency. The stimulator also utilizes closed-loop active charge balancing to maintain the residual charge at each site within a safe limit, while receiving the stimulation parameters wirelessly from the amplitude-shift-keyed power carrier. A 4-ch wireless stimulating system prototype was fabricated in a 0.5-μm 3M2P standard CMOS process, occupying 2.25 mm². With 5 V peak AC input at 2 MHz, the adaptive rectifier provides an adjustable DC output between 2.5 V and 4.6 V at 2.8 mA loading, resulting in measured PCE of 72 ~ 87%. The adaptive supply control increases the stimulation efficiency up to 30% higher than a fixed supply voltage to 58 ~ 68%. The prototype wireless stimulating system was verified in vitro. PMID:24678126