WorldWideScience

Sample records for hydraulic burst tests

  1. Evaluation of the thermal-hydraulic response and fuel rod thermal and mechanical deformation behavior during the power burst facility test LOC-3. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Yackle, T.R.; MacDonald, P.E.; Broughton, J.M.

    1980-01-01

    An evaluation of the results from the LOC-3 nuclear blowdown test conducted in the Power Burst Facility is presented. The test objective was to examine fuel and cladding behavior during a postulated cold leg break accident in a pressurized water reactor (PWR). Separate effects of rod internal pressure and the degree of irradiation were investigated in the four-rod test. Extensive cladding deformation (ballooning) and failure occurred during blowdown. The deformation of the low and high pressure rods was similar; however, the previously irradiated test rod deformed to a greater extent than a similar fresh rod exposed to identical system conditions.

  2. Theory and application of rock burst prevention using deep hole high pressure hydraulic fracturing

    Institute of Scientific and Technical Information of China (English)

    Shan-Kun ZHAO; Jun LIU; Xiang-Zhi WEI; Chuan-Hong DING; Yu-Lei LV; Gang-Feng LI

    2013-01-01

    In order to analyze the mechanism of deep hole high pressure hydraulic fracturing,nonlinear dynamic theory,damage mechanics,elastic-plastic mechanics are used,and the law of crack propagation and stress transfer under two deep hole hydraulic fracturing in tectonic stress areas is studied using seepage-stress coupling models with RFPA simulation software.In addition,the effects of rock burst control are tested using multiple methods,either in the stress field or in the energy field.The research findings show that with two deep holes hydraulic fracturing in tectonic stress areas,the direction of the main crack propagation under shear-tensile stress is parallel to the greatest principal stress direction.High-pressure hydraulic fracturing water seepage can result in the destruction of the coal structure,while also weakening the physical and mechanical properties of coal and rock.Therefore the impact of high stress concentration in hazardous areas will level off,which has an effect on rock burst prevention and control in the region.

  3. Failure Analysis of T-38 Aircraft Burst Hydraulic Aileron Return Line

    Science.gov (United States)

    Martinez, J. E.; Figert, J. D.; Paton, R. M.; Nguyen, S. D.; Flint, A.

    2012-01-01

    During maintenance troubleshooting for fluctuating hydraulic pressures, a technician found that a right hand aileron return line, on the flight hydraulic side, was ruptured (Fig. 1, 2). This tubing is part of the Hydraulic Flight Control Aileron Return Reducer to Aileron Manifold and is suspected to be original to the T-38 Talon trainer aircraft. Ailerons are small hinged sections on the outboard portion of a wing used to generate rolling motion thereby banking the aircraft. The ailerons work by changing the effective shape of the airfoil of the outer portion of the wing [1]. The drawing, Northrop P/N 3-43033-55 (6/1960), specifies that the line is made from 0.375 inch OD, aluminum 5052-0 tubing with a 0.049 inch wall thickness. WW-T-787 requires the tube shall be seamless and uniform in quality and temper [2]. The test pressure for this line is 3000 psi, and the operational pressure for this line is estimated to be between 45 psi and 1500 psi based on dynamic loading during flight. Examination of the fracture surface found evidence of arrest bands originating on the inner diameter (Fig 3). Ductile dimples are observed on the tube fractures (Fig. 4). The etched cross-section revealed thinning and work-hardening in the burst region (Fig. 5). The wall thickness just outside the work-hardened fracture region measured 0.035". Barlow's Formula: P = 2St/D, where P is burst pressure, S is allowable stress, t is wall thickness and D is the outer diameter of tube. Using the ultimate tensile strength of 28 ksi and a measured wall thickness of 0.035 inches at burst, P = 5.2 ksi (burst pressure). Using the yield of 13 ksi (YS) for aluminum 5052-0, plastic deformation will happen at P = 2.4 ksi suggesting plastic deformation occurred at a proof pressure of 3.0 ksi. Conclusion: The burst resulted from high stress, low-cycle fatigue. Evidence of arrest bands originating on the inner diameter. Fracture is predominately shear dimples, characteristic of high load ductile fractures

  4. Gas Test Loop Booster Fuel Hydraulic Testing

    Energy Technology Data Exchange (ETDEWEB)

    Gas Test Loop Hydraulic Testing Staff

    2006-09-01

    The Gas Test Loop (GTL) project is for the design of an adaptation to the Advanced Test Reactor (ATR) to create a fast-flux test space where fuels and materials for advanced reactor concepts can undergo irradiation testing. Incident to that design, it was found necessary to make use of special booster fuel to enhance the neutron flux in the reactor lobe in which the Gas Test Loop will be installed. Because the booster fuel is of a different composition and configuration from standard ATR fuel, it is necessary to qualify the booster fuel for use in the ATR. Part of that qualification is the determination that required thermal hydraulic criteria will be met under routine operation and under selected accident scenarios. The Hydraulic Testing task in the GTL project facilitates that determination by measuring flow coefficients (pressure drops) over various regions of the booster fuel over a range of primary coolant flow rates. A high-fidelity model of the NW lobe of the ATR with associated flow baffle, in-pile-tube, and below-core flow channels was designed, constructed and located in the Idaho State University Thermal Fluids Laboratory. A circulation loop was designed and constructed by the university to provide reactor-relevant water flow rates to the test system. Models of the four booster fuel elements required for GTL operation were fabricated from aluminum (no uranium or means of heating) and placed in the flow channel. One of these was instrumented with Pitot tubes to measure flow velocities in the channels between the three booster fuel plates and between the innermost and outermost plates and the side walls of the flow annulus. Flow coefficients in the range of 4 to 6.5 were determined from the measurements made for the upper and middle parts of the booster fuel elements. The flow coefficient for the lower end of the booster fuel and the sub-core flow channel was lower at 2.3.

  5. Hydraulic test for evaluation of hydrophone VSP

    Energy Technology Data Exchange (ETDEWEB)

    Yabuuchi, Satoshi; Koide, Kaoru [Power Reactor and Nuclear Fuel Development Corp., Toki, Gifu (Japan). Tono Geoscience Center

    1997-12-01

    This hydraulic test was carried out at the test site of Tono Geoscience Center, Mizunami-shi, Gifu Pref. in order to evaluate the reliability of the hydraulic conductivity estimated from hydrophone VSP experiment. From March to April 1997, we carried out measurements of pore-water pressure at five depths and permeability tests at seven depths down to G.L.-300m, within a borehole drilled in granitic rock. We compared the results of hydraulic test with hydrophone VSP experiment on condition that a single open fracture existed, and we obtained two notable results. First, for the granitic rock at which a single open fracture was found by BTV and also detected by hydrophone VSP experiment, the hydraulic conductivity was 1.54 x 10{sup -7} cm/sec, while for the same granitic rock at which another single open fracture was found by BTV but not detected by hydrophone VSP experiment, the hydraulic conductivity was less than 6 x 10{sup -10} cm/sec. Second, we converted the hydraulic conductivity of 1.54 x 10{sup -7} cm/sec which was obtained in a hydraulic test section of length 2.5 m into an equivalent value for a single open fracture of width 1 mm. The converted value (3.8 x 10{sup -4} cm/sec) was similar to the hydraulic conductivity estimated from hydrophone VSP experiment. In conclusion, the hydraulic test result shows that hydrophone VSP is useful to estimate an approximate hydraulic conductivity of a single open fracture. (author)

  6. Critical Test Of Gamma Ray Burst Theories

    CERN Document Server

    Dado, Shlomo

    2016-01-01

    Long and precise follow-up measurements of the X-ray afterglow (AG) of very intense gamma ray bursts (GRBs) provide a critical test of GRB afterglow theories. Here we show that the power-law decline with time of X-ray AG of GRB 130427A, the longest measured X-ray AG of an intense GRB with the Swift, Chandra and XMM Newton satellites, and of all other well measured late-time X-ray afterglow of intense GRBs, is that predicted by the cannonball (CB) model of GRBs from their measured spectral index, while it disagrees with that predicted by the widely accepted fireball (FB) models of GRBs.

  7. The Thermal Hydraulic Test of SFR Irradiation Test Capsule

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chul Yong; Park, Sung Jae; Choo, Kee Nam [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-10-15

    Irradiation test using a capsule has been performed for fuel or material performance test in the test reactor. Irradiation capsule for the HANARO reactor must satisfy the hydraulic conditions and structural integrity from a out-pile test. Items of a out-pile test are pressure drop, flow-induced vibration test and endurance test. The results of test must show that a test capsule satisfy the HANARO operational requirement with sufficient margin. This paper describes the devices of thermal hydraulic test and the results of SFR test capsule

  8. Mechanization of hydraulic testing of chemical equipment

    Energy Technology Data Exchange (ETDEWEB)

    Bannikov, M.T.; Fridman, R.N.; Petrovnin, A.I.

    1982-09-01

    The Institute VNIIPTKhimmash has worked out a comprehensive list of equipment for testing for strength and tightness containers and heat exchangers with jackets, with mixers, also of individual parts and subassemblies for this equipment. Points out that in the test stands developed for hydraulic testing of vessels both individual and centralized recirculating water supply can be used. Concludes that a reduction in labor consumption in hydraulic testing and in servicing of all the equipment used, an increase in the mechanization of this kind of chemical equipment, and the solution of the problem of standardization not only with regard to dimensions and parameters, but also with regard to the makes and types of the materials used, will make possible a considerable increase in labor productivity and product quality.

  9. Pilot testing of a hydraulic bridge exciter

    Directory of Open Access Journals (Sweden)

    Andersson Andreas

    2015-01-01

    Full Text Available This paper describes the development of a hydraulic bridge exciter and its first pilot testing on a full scale railway bridge in service. The exciter is based on a hydraulic load cylinder with a capacity of 50 kN and is intended for controlled dynamic loading up to at least 50 Hz. The load is applied from underneath the bridge, enabling testing while the railway line is in service. The system is shown to produce constant load amplitude even at resonance. The exciter is used to experimentally determine frequency response functions at all sensor locations, which serve as valuable input for model updating and verification. An FE-model of the case study bridge has been developed that is in good agreement with the experimental results.

  10. Formed Core Sampler Hydraulic Conductivity Testing

    Energy Technology Data Exchange (ETDEWEB)

    Miller, D. H.; Reigel, M. M.

    2012-09-25

    A full-scale formed core sampler was designed and functionally tested for use in the Saltstone Disposal Facility (SDF). Savannah River National Laboratory (SRNL) was requested to compare properties of the formed core samples and core drilled samples taken from adjacent areas in the full-scale sampler. While several physical properties were evaluated, the primary property of interest was hydraulic conductivity. Differences in hydraulic conductivity between the samples from the formed core sampler and those representing the bulk material were noted with respect to the initial handling and storage of the samples. Due to testing conditions, the site port samples were exposed to uncontrolled temperature and humidity conditions prior to testing whereas the formed core samples were kept in sealed containers with minimal exposure to an uncontrolled environment prior to testing. Based on the results of the testing, no significant differences in porosity or density were found between the formed core samples and those representing the bulk material in the test stand.

  11. Thermal Hydraulic Tests for Reactor Core Safety

    Energy Technology Data Exchange (ETDEWEB)

    Moon, S. K.; Baek, W. P.; Chun, S. Y. (and others)

    2007-06-15

    The main objectives of the present project are to resolve the current issues of reactor core thermal hydraulics, to develop an advanced measurement and analytical techniques, and to perform reactor core safety verification tests. 6x6 reflood experiments, various heat transfer experiments using Freon, and experiments on the spacer grids effects on the post-dryout are carried out using spacer grids developed in Korea in order to resolve the current issues of the reactor core thermal hydraulics. In order to develop a reflood heat transfer model, the detailed reflood phenomena are visualized and measured using round tube and 2x2 rod bundle. A detailed turbulent mixing phenomenon for subchannels is measured using advanced measurement techniques such as LDV and PIV. MARS and MATRA codes developed in Korea are assessed, verified and improved using the obtained experimental data. Finally, a systematic quality assurance program and experimental data generation system has been constructed in order to increase the reliability of the experimental data.

  12. Design of a laboratory hydraulic device for testing of hydraulic pumps

    Directory of Open Access Journals (Sweden)

    Pavel Máchal

    2013-01-01

    Full Text Available The present contribution deals with solves problem of research of testing device to monitor of hydrostatic pumps durability about dynamic loading under laboratory conditions. When carrying out the design of testing device are based on load characteristics of tractor hydraulic circuit, the individual characteristics of hydraulic components and performed calculations. Load characteristics on the tractors CASE IH Magnum 310, JOHN DEERE 8100, ZETOR FORTERRA 114 41 and Fendt 926 Vario were measured. Design of a hydraulic laboratory device is based on the need for testing new types of hydraulic pumps or various types of hydraulic fluids. When creating of hydraulic device we focused on testing hydraulic pumps used in agricultural and forestry tractors. Proportional pressure control valve is an active member of the hydraulic device, which provides change of a continuous control signal into relative pressure of operating fluid. The advantage of a designed hydraulic system is possibility of simulation of dynamic operating loading, which is obtained by measurement under real conditions, and thereby creates laboratory conditions as close to real conditions as possible. The laboratory device is constructed at the Department of Transport and Handling, Faculty of Engineering, Slovak University of Agriculture in Nitra.

  13. Research on hydraulic-powered roof supports test problems

    Institute of Scientific and Technical Information of China (English)

    SUN Hong-bo; JIANG Jin-qiu; MA Qiang

    2011-01-01

    The load-bearing characters of hydraulic-powered roof support with dual telescopic legs were analyzed. With a specific type hydraulic-powered roof support with dual telescopic legs for research object, the inside load test problems in factories was analyzed, and the correct test methods were given, which can enhance the test efficiency and make the factories away from the error design of hydraulic-powered roof supports and legs.

  14. Creep Burst Testing of a Woven Inflatable Module

    Science.gov (United States)

    Selig, Molly M.; Valle, Gerard D.; James, George H.; Oliveras, Ovidio M.; Jones, Thomas C.; Doggett, William R.

    2015-01-01

    A woven Vectran inflatable module 88 inches in diameter and 10 feet long was tested at the NASA Johnson Space Center until failure from creep. The module was pressurized pneumatically to an internal pressure of 145 psig, and was held at pressure until burst. The external environment remained at standard atmospheric temperature and pressure. The module burst occurred after 49 minutes at the target pressure. The test article pressure and temperature were monitored, and video footage of the burst was captured at 60 FPS. Photogrammetry was used to obtain strain measurements of some of the webbing. Accelerometers on the test article measured the dynamic response. This paper discusses the test article, test setup, predictions, observations, photogrammetry technique and strain results, structural dynamics methods and quick-look results, and a comparison of the module level creep behavior to the strap level creep behavior.

  15. INFORMATION-MEASURING TEST SYSTEM OF DIESEL LOCOMOTIVE HYDRAULIC TRANSMISSIONS

    Directory of Open Access Journals (Sweden)

    I. V. Zhukovytskyy

    2015-08-01

    Full Text Available Purpose. The article describes the process of developing the information-measuring test system of diesel locomotives hydraulic transmission, which gives the possibility to obtain baseline data to conduct further studies for the determination of the technical condition of diesel locomotives hydraulic transmission. The improvement of factory technology of post-repair tests of hydraulic transmissions by automating the existing hydraulic transmission test stands according to the specifications of the diesel locomotive repair enterprises was analyzed. It is achieved based on a detailed review of existing foreign information-measuring test systems for hydraulic transmission of diesel locomotives, BelAZ earthmover, aircraft tug, slag car, truck, BelAZ wheel dozer, some brands of tractors, etc. The problem for creation the information-measuring test systems for diesel locomotive hydraulic transmission is being solved, starting in the first place from the possibility of automation of the existing test stand of diesel locomotives hydraulic transmission at Dnipropetrovsk Diesel Locomotive Repair Plant "Promteplovoz". Methodology. In the work the researchers proposed the method to create a microprocessor automated system of diesel locomotives hydraulic transmission stand testing in the locomotive plant conditions. It acts by justifying the selection of the necessary sensors, as well as the application of the necessary hardware and software for information-measuring systems. Findings. Based on the conducted analysis there was grounded the necessity of improvement the plant hydraulic transmission stand testing by creating a microprocessor testing system, supported by the experience of developing such systems abroad. Further research should be aimed to improve the accuracy and frequency of data collection by adopting the more modern and reliable sensors in tandem with the use of filtering software for electromagnetic and other interference. Originality. The

  16. Hydraulics.

    Science.gov (United States)

    Decker, Robert L.; Kirby, Klane

    This curriculum guide contains a course in hydraulics to train entry-level workers for automotive mechanics and other fields that utilize hydraulics. The module contains 14 instructional units that cover the following topics: (1) introduction to hydraulics; (2) fundamentals of hydraulics; (3) reservoirs; (4) lines, fittings, and couplers; (5)…

  17. Determination of Material Strengths by Hydraulic Bulge Test

    Directory of Open Access Journals (Sweden)

    Hankui Wang

    2016-12-01

    Full Text Available The hydraulic bulge test (HBT method is proposed to determine material tensile strengths. The basic idea of HBT is similar to the small punch test (SPT, but inspired by the manufacturing process of rupture discs—high-pressure hydraulic oil is used instead of punch to cause specimen deformation. Compared with SPT method, the HBT method can avoid some of influence factors, such as punch dimension, punch material, and the friction between punch and specimen. A calculation procedure that is entirely based on theoretical derivation is proposed for estimate yield strength and ultimate tensile strength. Both conventional tensile tests and hydraulic bulge tests were carried out for several ferrous alloys, and the results showed that hydraulic bulge test results are reliable and accurate.

  18. Determination of Material Strengths by Hydraulic Bulge Test.

    Science.gov (United States)

    Wang, Hankui; Xu, Tong; Shou, Binan

    2016-12-30

    The hydraulic bulge test (HBT) method is proposed to determine material tensile strengths. The basic idea of HBT is similar to the small punch test (SPT), but inspired by the manufacturing process of rupture discs-high-pressure hydraulic oil is used instead of punch to cause specimen deformation. Compared with SPT method, the HBT method can avoid some of influence factors, such as punch dimension, punch material, and the friction between punch and specimen. A calculation procedure that is entirely based on theoretical derivation is proposed for estimate yield strength and ultimate tensile strength. Both conventional tensile tests and hydraulic bulge tests were carried out for several ferrous alloys, and the results showed that hydraulic bulge test results are reliable and accurate.

  19. Periodic Hydraulic Testing for Discerning Fracture Network Connections

    Science.gov (United States)

    Becker, M.; Le Borgne, T.; Bour, O.; Guihéneuf, N.; Cole, M.

    2015-12-01

    Discrete fracture network (DFN) models often predict highly variable hydraulic connections between injection and pumping wells used for enhanced oil recovery, geothermal energy extraction, and groundwater remediation. Such connections can be difficult to verify in fractured rock systems because standard pumping or pulse interference tests interrogate too large a volume to pinpoint specific connections. Three field examples are presented in which periodic hydraulic tests were used to obtain information about hydraulic connectivity in fractured bedrock. The first site, a sandstone in New York State, involves only a single fracture at a scale of about 10 m. The second site, a granite in Brittany, France, involves a fracture network at about the same scale. The third site, a granite/schist in the U.S. State of New Hampshire, involves a complex network at scale of 30-60 m. In each case periodic testing provided an enhanced view of hydraulic connectivity over previous constant rate tests. Periodic testing is particularly adept at measuring hydraulic diffusivity, which is a more effective parameter than permeability for identify the complexity of flow pathways between measurement locations. Periodic tests were also conducted at multiple frequencies which provides a range in the radius of hydraulic penetration away from the oscillating well. By varying the radius of penetration, we attempt to interrogate the structure of the fracture network. Periodic tests, therefore, may be uniquely suited for verifying and/or calibrating DFN models.

  20. Closest Gamma Ray Burst Providing Scientists With Crucial Test for Burst Physics

    Science.gov (United States)

    2003-05-01

    says that the radio emission comes from a rapidly-expanding shock wave. This model was first proposed by Peter Meszaros, Bohdan Paczynski and Sir Martin Rees, who won the American Astronomical Society's Bruno Rossi Prize in 2000 for their work. In this standard model, as the shock wave expands outward, the emission becomes fainter, but the center of the observed emission does not change position. The cannonball model, however, proposes that the emission arises from distinct concentrations of matter shot outward from the burst. As they move farther from the burst, their motion should be detected as a change in their position in the sky. On April 3, proponents of the cannonball model predicted a specific amount of motion for GRB 030329 and suggested that the VLBA's sharp radio "vision" could detect the motion and confirm their prediction. Instead, "our observations are consistent with no motion at all," Taylor said. "This is at odds with the cannonball model -- they made a specific prediction based on their model and the observations do not bear them out," he added. The scientists' direct measurement of the size of the GRB fireball also will provide new insights into the physics behind the burst. "By directly measuring the size and the expansion rate, we can start putting some real limits on the physics involved," Taylor said. First, he said, "We already can confirm that the fireball is expanding at nearly the speed of light, as the standard model predicts. Next, once our May observations are fully analyzed, we can put limits on the energy of the burst and provide a test of the standard model." Taylor and Frail observed GRB 030329 with the VLBA on April 1 and April 6. On April 22, they used the 100-meter radio telescope in Effelsberg, Germany in addition to the VLBA. On May 19, they used the VLBA, the Very Large Array (VLA) in New Mexico, the NSF's Robert C. Byrd Green Bank Telescope in West Virginia, and the Effelsberg telescope. In addition to gamma-ray and X

  1. Thermal Hydraulic Integral Effect Tests for Pressurized Water Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Baek, W. P.; Song, C. H.; Kim, Y. S. and others

    2005-02-15

    The objectives of the project are to construct a thermal-hydraulic integral effect test facility and to perform various integral effect tests for design, operation, and safety regulation of pressurized water reactors. During the first phase of this project (1997.8{approx}2002.3), the basic technology for thermal-hydraulic integral effect tests was established and the basic design of the test facility was accomplished: a full-height, 1/300-volume-scaled full pressure facility for APR1400, an evolutionary pressurized water reactor that was developed by Korean industry. Main objectives of the present phase (2002.4{approx}2005.2), was to optimize the facility design and to construct the experimental facility. We have performed following researches: 1) Optimization of the basic design of the thermal-hydraulic integral effect test facility for PWRs - ATLAS (Advanced Thermal-hydraulic Test Loop for Accident Simulation) - Reduced height design for APR1400 (+ specific design features of KSNP safety injection systems) - Thermal-hydraulic scaling based on three-level scaling methodology by Ishii et al. 2) Construction of the ATLAS facility - Detailed design of the test facility - Manufacturing and procurement of components - Installation of the facility 3) Development of supporting technology for integral effect tests - Development and application of advanced instrumentation technology - Preliminary analysis of test scenarios - Development of experimental procedures - Establishment and implementation of QA system/procedure.

  2. Laboratory tests of hydraulic fracturing and swell healing

    DEFF Research Database (Denmark)

    Thunbo, Christensen Claes; Foged, Christensen Helle; Foged, Niels

    1998-01-01

    New laboratory test set-ups and test procedures are described - for testing the formation of hydraulically induced fractures as well as the potential for subsequent fracture closurefrom the relase of a swelling potential. The main purpose with the tests is to provide information on fracturing...

  3. Hydraulic Hybrid Parcel Delivery Truck Deployment, Testing & Demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Gallo, Jean-Baptiste [Calstart Incorporated, Pasadena, CA (United States)

    2014-03-07

    Although hydraulic hybrid systems have shown promise over the last few years, commercial deployment of these systems has primarily been limited to Class 8 refuse trucks. In 2005, the Hybrid Truck Users Forum initiated the Parcel Delivery Working Group including the largest parcel delivery fleets in North America. The goal of the working group was to evaluate and accelerate commercialization of hydraulic hybrid technology for parcel delivery vehicles. FedEx Ground, Purolator and United Parcel Service (UPS) took delivery of the world’s first commercially available hydraulic hybrid parcel delivery trucks in early 2012. The vehicle chassis includes a Parker Hannifin hydraulic hybrid drive system, integrated and assembled by Freightliner Custom Chassis Corp., with a body installed by Morgan Olson. With funding from the U.S. Department of Energy, CALSTART and its project partners assessed the performance, reliability, maintainability and fleet acceptance of three pre-production Class 6 hydraulic hybrid parcel delivery vehicles using information and data from in-use data collection and on-road testing. This document reports on the deployment of these vehicles operated by FedEx Ground, Purolator and UPS. The results presented provide a comprehensive overview of the performance of commercial hydraulic hybrid vehicles in parcel delivery applications. This project also informs fleets and manufacturers on the overall performance of hydraulic hybrid vehicles, provides insights on how the technology can be both improved and more effectively used. The key findings and recommendations of this project fall into four major categories: -Performance, -Fleet deployment, -Maintenance, -Business case. Hydraulic hybrid technology is relatively new to the market, as commercial vehicles have been introduced only in the past few years in refuse and parcel delivery applications. Successful demonstration could pave the way for additional purchases of hydraulic hybrid vehicles throughout the

  4. Oscillatory Flow Testing in a Sandbox - Towards Oscillatory Hydraulic Tomography

    Science.gov (United States)

    Zhou, Y.; Lim, D.; Cupola, F.; Cardiff, M. A.

    2014-12-01

    Detailed knowledge of subsurface hydraulic properties is important for predicting groundwater flow and contaminant transport. The spatial variation of hydraulic properties in the shallow subsurface has been extensively studied in the past two decades. A recent approach to characterize subsurface properties is hydraulic tomography, in which pressure data from multiple constant-rate pumping tests is inverted using a numerical model. Many laboratory sandbox studies have explored the performance of hydraulic tomography under different controlled conditions and shown that detailed heterogeneity information can be extracted (Liu et al., 2002, Illman et al., 2007, 2008, 2010a, 2010b, Liu et al., 2007, 2008, Xiang et al., 2009, Yin and Illman, 2009, Liu and Kitanidis, 2011, Berg and Illman, 2011a). Recently, Cardiff et al. (2013) proposed a modified approach of Oscillatory Hydraulic Tomography (OHT) - in which periodic pumping signals of different frequencies are used for aquifer stimulation - to characterize aquifer properties. The potential advantages of OHT over traditional hydraulic tomography include: 1) no net injection or extraction of water; 2) little movement of existing contamination; 3) minimal impact of model boundary conditions; and 4) robust extraction of oscillatory signals from noisy data. To evaluate the premise of OHT, we built a highly-instrumented 2-D laboratory sandbox and record pressure responses to periodic pumping tests. In our setup, the laboratory sandbox is filled with sand of known hydraulic properties, and we measure aquifer responses at a variety of testing frequencies. The signals recorded are processed using Fourier-domain analysis, and compared against expected results under linear (Darcian) theory. The responses are analyzed using analytical and numerical models, which provide key insights as to: 1) how "effective" hydraulic properties estimated using homogeneous models are associated with aquifer heterogeneity; and 2) how OHT is able to

  5. A Static Burst Test for Composite Flywheel Rotors

    Science.gov (United States)

    Hartl, Stefan; Schulz, Alexander; Sima, Harald; Koch, Thomas; Kaltenbacher, Manfred

    2016-06-01

    High efficient and safe flywheels are an interesting technology for decentralized energy storage. To ensure all safety aspects, a static test method for a controlled initiation of a burst event for composite flywheel rotors is presented with nearly the same stress distribution as in the dynamic case, rotating with maximum speed. In addition to failure prediction using different maximum stress criteria and a safety factor, a set of tensile and compressive tests is carried out to identify the parameters of the used carbon fiber reinforced plastics (CFRP) material. The static finite element (FE) simulation results of the flywheel static burst test (FSBT) compare well to the quasistatic FE-simulation results of the flywheel rotor using inertia loads. Furthermore, it is demonstrated that the presented method is a very good controllable and observable possibility to test a high speed flywheel energy storage system (FESS) rotor in a static way. Thereby, a much more expensive and dangerous dynamic spin up test with possible uncertainties can be substituted.

  6. Hydraulic Tomography and High-Resolution Slug Testing to Determine Hydraulic Conductivity Distributions - Year 1

    Science.gov (United States)

    2005-12-01

    the addition into a well of a known volume of water or a physical slug. More recently, pneumatic methods have become popular ( Zemansky and McElwee...and Zemansky , 2000), (Sellwood, 2001) and (Ross, 2004)]. The aquifer material at GEMS exhibits linear and non-linear responses to slug testing...1976; Zurbuchen et al., 2002; and Zemansky and McElwee, 2005). Slug tests have been a common method for obtaining information about the hydraulic

  7. State of the art hydraulic turbine model test

    Science.gov (United States)

    Fabre, Violaine; Duparchy, Alexandre; Andre, Francois; Larroze, Pierre-Yves

    2016-11-01

    Model tests are essential in hydraulic turbine development and related fields. The methods and technologies used to perform these tests show constant progress and provide access to further information. In addition, due to its contractual nature, the test demand evolves continuously in terms of quantity and accuracy. Keeping in mind that the principal aim of model testing is the transposition of the model measurements to the real machine, the measurements should be performed accurately, and a critical analysis of the model test results is required to distinguish the transposable hydraulic phenomena from the test rig interactions. Although the resonances’ effects are known and described in the IEC standard, their identification is difficult. Leaning on a strong experience of model testing, we will illustrate with a few examples of how to identify the potential problems induced by the test rig. This paper contains some of our best practices to obtain the most accurate, relevant, and independent test-rig measurements.

  8. Testing and Performance of UFFO Burst Alert & Trigger Telescope

    CERN Document Server

    Ripa, J; Lee, J; Park, I H; Kim, J E; Lim, H; Jeong, S; Castro-Tirado, A J; Connell, P H; Eyles, C; Reglero, V; Rodrigo, J M; Bogomolov, V; Panasyuk, M I; Petrov, V; Svertilov, S; Yashin, I; Brandt, S; Budtz-Jorgensen, C; Chang, Y -Y; Chen, P; Huang, M A; Liu, T -C; Nam, J W; Wang, M -Z; Chen, C R; Choi, H S; Kim, S -W; Min, K W

    2015-01-01

    The Ultra-Fast Flash Observatory pathfinder (UFFO-p) is a new space mission dedicated to detect Gamma-Ray Bursts (GRBs) and rapidly follow their afterglows in order to provide early optical/ultraviolet measurements. A GRB location is determined in a few seconds by the UFFO Burst Alert & Trigger telescope (UBAT) employing the coded mask imaging technique and the detector combination of Yttrium Oxyorthosilicate (YSO) scintillating crystals and multi-anode photomultiplier tubes. The results of the laboratory tests of UBAT's functionality and performance are described in this article. The detector setting, the pixel-to-pixel response to X-rays of different energies, the imaging capability for <50 keV X-rays, the localization accuracy measurements, and the combined test with the Block for X-ray and Gamma-Radiation Detection (BDRG) scintillator detector to check the efficiency of UBAT are all described. The UBAT instrument has been assembled and integrated with other equipment on UFFO-p and should be launche...

  9. Burst tests on pipeline with long external corrosion

    Energy Technology Data Exchange (ETDEWEB)

    Benjamin, A.C. [Rio de Janeiro Univ., (Brazil); Vieira, R.D.; Freire, J.L.F.; Castro, J.T.P. de [PUC, Rio de Janeiro (Brazil)

    2000-07-01

    Four different methods are available to assess long corrosion defects. They are: ASME B31G, RSTRENG 085dL, RSTRENG Effective Area, and the DNV RP-F101 (Part B). The degree of conservatism in each method varies considerably, making the maintenance and repair costs higher than they could be, since pipes still fit for service are replaced based on the results obtained in evaluating pressure strength. Petrobras initiated a research project aimed at assessing the behavior of pipeline with long corrosion defects. CONFAB S.A., a Brazilian manufacturer of steel tubes, donated 5 longitudinal welded tubes made of API 5L X60 steel. The wall thickness was 9.53 mm and the outside diameter was 323.9 mm. Two tubular specimens 2 m long were cut from each of the tubes, except for one tube where only one 2 m long section was cut. Burst tests were conducted on the specimens, where the corrosion defects were smooth and rectangular, having been fabricated using spark erosion. Material properties were determined on tensile specimens. 10 post-yield strain gages rosettes, one displacement transducer and three pressure transducers were affixed to the corroded specimens. A comparison of the measured burst pressures was made as predicted by the four methods under investigation. 11 refs., 4 tabs., 5 figs.

  10. Testing Einstein's Equivalence Principle with Fast Radio Bursts

    CERN Document Server

    Wei, Jun-Jie; Wu, Xue-Feng; Mészáros, Peter

    2015-01-01

    The accuracy of Einstein's Equivalence Principle (EEP) can be tested with the observed time delays between correlated particles or photons that are emitted from astronomical sources. Assuming as a lower limit that the time delays are caused mainly by the gravitational potential of the Milky Way, we prove that fast radio bursts (FRBs) of cosmological origin can be used to constrain the EEP with high accuracy. Taking FRB 110220 and two possible FRB/gamma-ray burst (GRB) association systems (FRB/GRB 101011A and FRB/GRB 100704A) as examples, we obtain a strict upper limit on the differences of the parametrized post-Newtonian parameter $\\gamma$ values as low as $\\left[\\gamma(1.23\\; \\rm GHz)-\\gamma(1.45\\; \\rm GHz)\\right]<4.36\\times10^{-9}$. This provides the most stringent limit up to date on the EEP through the relative differential variations of the $\\gamma$ parameter at radio energies, improving by 1 to 2 orders of magnitude the previous results at other energies based on supernova 1987A and GRBs.

  11. Hydraulic Model Tests on Modified Wave Dragon

    DEFF Research Database (Denmark)

    Hald, Tue; Lynggaard, Jakob

    A floating model of the Wave Dragon (WD) was built in autumn 1998 by the Danish Maritime Institute in scale 1:50, see Sørensen and Friis-Madsen (1999) for reference. This model was subjected to a series of model tests and subsequent modifications at Aalborg University and in the following...... are found in Hald and Lynggaard (2001). Model tests and reconstruction are carried out during the phase 3 project: ”Wave Dragon. Reconstruction of an existing model in scale 1:50 and sequentiel tests of changes to the model geometry and mass distribution parameters” sponsored by the Danish Energy Agency...

  12. VISTA : thermal-hydraulic integral test facility for SMART reactor

    Energy Technology Data Exchange (ETDEWEB)

    Choi, K. Y.; Park, H. S.; Cho, S.; Park, C. K.; Lee, S. J.; Song, C. H.; Chung, M. K. [KAERI, Taejon (Korea, Republic of)

    2003-07-01

    Preliminary performance tests were carried out using the thermal-hydraulic integral test facility, VISTA (Experimental Verification by Integral Simulation of Transients and Accidents), which has been constructed to simulate the SMART-P. The VISTA facility is an integral test facility including the primary and secondary systems as well as safety-related Passive Residual Heat Removal (PRHR) systems. Its scaled ratio with respect to the SMART-P is 1/1 in height and 1/96 in volume and heater power. Several steady states and power changing tests have been carried out to verify the overall thermal hydraulic primary and secondary characteristics in the range of 10% to 100% power operation. As for the preliminary results, the steady state conditions were found to coincide with the expected design values of the SMART-P. But the major thermal hydraulic parameters are greatly affected by the initial water level and the nitrogen pressure in the reactor's upper annular cavity. The power step/ramp changing tests are successfully carried out and the system responses are observed. The primary natural circulation operation is achieved, but advanced control logics need to be developed to reach the natural circulation mode without pressure excursion. In the PRHR transient tests, the natural circulation flow rate through the PRHR system was found to be about 10 percent in the early phases of PRHR operation.

  13. Acceptance test report for the Westinghouse 100 ton hydraulic trailer

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, R.A.

    1995-03-06

    The SY-101 Equipment Removal System 100 Ton Hydraulic Trailer was designed and built by KAMP Systems, Inc. Performance of the Acceptance Test Procedure at KAMP`s facility in Ontario, California (termed Phase 1 in this report) was interrupted by discrepancies noted with the main hydraulic cylinder. The main cylinder was removed and sent to REMCO for repair while the trailer was sent to Lampson`s facility in Pasco, Washington. The Acceptance Test Procedure was modified and performance resumed at Lampson (termed Phase 2 in this report) after receipt of the repaired cylinder. At the successful conclusion of Phase 2 testing the trailer was accepted as meeting all the performance criteria specified.

  14. Testing Einstein's Equivalence Principle with Short Gamma-ray Bursts

    CERN Document Server

    Sang, Yu; Chang, Zhe

    2016-01-01

    Einstein's equivalence principle (EEP) can be tested by the time delay between photons with different energies passing through a gravitational field. As one of the most energetic explosions in the Universe, gamma-ray bursts (GRBs) provide an effective tool to test the accuracy of EEP. In this paper, we use the continuous spectra of 20 short GRBs detected by the Swift/BAT to test the validity of EEP. Taking the duration of GRBs as the upper limit of the time delay induced by EEP violation (assuming that the high energy photons arrive later than the low energy photons), the difference of the parameterized post-Newtonian parameter is constrained with high accuracy. The strictest constraint, $|\\gamma(150~{\\rm keV})-\\gamma(15~{\\rm keV})|<5.59\\times 10^{-10}$ from GRB 150101B, is about $1\\sim 2$ orders of magnitude tighter than previous constraints. Moreover, our result is more statistically significant than previous results because we use the continuous spectra instead of isolated photons.

  15. Flammability Tests on Hot Surface for Several Hydraulic Fluids

    Directory of Open Access Journals (Sweden)

    L. Deleanu

    2011-09-01

    Full Text Available Industrial equipment using hydraulic fluids are design to accept higher load and speed, implicitly higher temperatures, including for fluids. Leakages from enclosures like gear boxes or hydraulic systems could increase the risk of fluid reaching hot surfaces, thus producing fires hard to be controlled and isolated. The designer have to evaluate the flammability of fluids and they should select several solutions for a particular application in order to estimate the costs of different solutions and to mitigate the risk of having accidental fires due to a specific fluid grade. The tests were done with the help of an original equipment allowing a dedicated soft assistance in order to protect the operator and to sustain reproducibility, according to the standard SR EN ISO 20823:2004 Petroleum and related products. The determination of the flammability characteristics of fluids in contact with hot surfaces - Manifold ignition test, There were tested the following grades of hydraulic oil HLP 68 X-Oil, HFC Prista, MHE 40 Prista (100% oil, a rapeseed oil (obtained after a dewaxing process and an emulsion oil-in-water (5% vol. MHE 40 Prista. There were identified distinct behaviours of these fluids under the test conditions

  16. Rock burst proneness prediction by acoustic emission test during rock deformation

    Institute of Scientific and Technical Information of China (English)

    张志镇; 高峰; 尚晓吉

    2014-01-01

    Rock burst is a severe disaster in mining and underground engineering, and it is important to predict the rock burst risk for minimizing the loss during the constructing process. The rock burst proneness was connected with the acoustic emission (AE) parameter in this work, which contributes to predicting the rock burst risk using AE technique. Primarily, a rock burst proneness index is proposed, and it just depends on the heterogeneous degree of rock material. Then, the quantificational formula between the value of rock burst proneness index and the accumulative AE counts in rock sample under uniaxial compression with axial strain increases is developed. Finally, three kinds of rock samples, i.e., granite, limestone and sandstone are tested about variation of the accumulative AE counts under uniaxial compression, and the test data are fitted well with the theoretic formula.

  17. Workgroup for Hydraulic laboratory Testing and Verification of Hydroacoustic Instrumentation

    Science.gov (United States)

    Fulford, Janice M.; Armstrong, Brandy N.; Thibodeaux, Kirk G.

    2015-01-01

    An international workgroup was recently formed for hydraulic laboratory testing and verification of hydroacoustic instrumentation used for water velocity measurements. The activities of the workgroup have included one face to face meeting, conference calls and an inter-laboratory exchange of two acoustic meters among participating laboratories. Good agreement was found among four laboratories at higher tow speeds and poorer agreement at the lowest tow speed.

  18. V/V(max) test applied to SMM gamma-ray bursts

    Science.gov (United States)

    Matz, S. M.; Higdon, J. C.; Share, G. H.; Messina, D. C.; Iadicicco, A.

    1992-01-01

    We have applied the V/V(max) test to candidate gamma-ray bursts detected by the Gamma-Ray Spectrometer (GRS) aboard the SMM satellite to examine quantitatively the uniformity of the burst source population. For a sample of 132 candidate bursts identified in the GRS data by an automated search using a single uniform trigger criterion we find average V/V(max) = 0.40 +/- 0.025. This value is significantly different from 0.5, the average for a uniform distribution in space of the parent population of burst sources; however, the shape of the observed distribution of V/V(max) is unusual and our result conflicts with previous measurements. For these reasons we can currently draw no firm conclusion about the distribution of burst sources.

  19. Turbine efficiency test on a large hydraulic turbine unit

    Institute of Scientific and Technical Information of China (English)

    YAN ZongGuo; ZHOU LingJiu; WANG ZhengWei

    2012-01-01

    The flow rate measurements are the most difficult part of efficiency tests on prototype hydraulic turbines.Among the numerous flow rate measurement methods,the Winter Kennedy method is preferred for measuring turbine flow rates,since it is convenient,practical and economical.This paper describes efficiency tests on a large 300 MW Francis turbine,with the flow rate measured using the Winter Kennedy method and the Winter Kennedy flow rate coefficient calibrated using the Gibson method.The measured turbine efficiency curve is then compared with the curve provided by the manufacturer.The CFD calculations including the spiral case are then used to analyze the influence with the coefficient K and index n in the Winter Kennedy flow rate formula on the flow rate measurement.The uncertainty values of n and K are a key reason for the differences between the curves obtained from the efficiency test and the curves provided by the manufacturer.

  20. In-Plant Testing of High-Efficiency Hydraulic Separators

    Energy Technology Data Exchange (ETDEWEB)

    G. H. Luttrell; R. Q. Honaker; R. C. Bratton; T. C. Westerfield; J. N. Kohmuench

    2006-06-30

    Hydraulic separators are commonly used for particle size classification and gravity concentration of minerals and coal. Unfortunately, the efficiency of these processes can be quite low due to poor equipment design and variations in feed consistency. To help alleviate these problems, an industry-driven R&D program has been undertaken to develop a new generation of hydraulic separators that are more efficient and less costly to operate and maintain. These units, which are commercially called the CrossFlow separator and HydroFloat separator, have the potential to improve performance (separation efficiency and throughput) and reduce operating costs (power consumption, water and reagent usage). In Phase I of this project, laboratory and pilot-scale test units were evaluated at various industrial sites in both the coal and mineral industries. Based on promising results obtained from Phase I, full-scale prototypes were purchased and installed by a major U.S. phosphate producer and a large eastern U.S. coal company. The test data obtained from these sites demonstrate that significant performance improvements can be realized through the application of these high-efficiency separators.

  1. IN-PLANT TESTING OF HIGH-EFFICIENCY HYDRAULIC SEPARATORS

    Energy Technology Data Exchange (ETDEWEB)

    G.H. Luttrell; R.Q. Honaker; R.C. Bratton; T.C. Westerfield; J.N. Kohmuench

    2006-05-22

    Hydraulic separators are commonly used for particle size classification and gravity concentration of minerals and coal. Unfortunately, the efficiency of these processes can be quite low due to poor equipment design and variations in feed consistency. To help alleviate these problems, an industry-driven R&D program has been undertaken to develop a new generation of hydraulic separators that are more efficient and less costly to operate and maintain. These units, which are commercially called the CrossFlow separator and HydroFloat separator, have the potential to improve performance (separation efficiency and throughput) and reduce operating costs (power consumption, water and reagent usage). In Phase I of this project, laboratory and pilot-scale test units were evaluated at various industrial sites in both the coal and mineral industries. Based on promising results obtained from Phase I, full-scale prototypes were purchased and installed by a major U.S. phosphate producer and a large eastern U.S. coal company. The test data obtained from these sites demonstrate that significant performance improvements can be realized through the application of these high-efficiency separators.

  2. Coordination of stem and leaf hydraulic conductance in southern California shrubs: a test of the hydraulic segmentation hypothesis.

    Science.gov (United States)

    Pivovaroff, Alexandria L; Sack, Lawren; Santiago, Louis S

    2014-08-01

    Coordination of water movement among plant organs is important for understanding plant water use strategies. The hydraulic segmentation hypothesis (HSH) proposes that hydraulic conductance in shorter lived, 'expendable' organs such as leaves and longer lived, more 'expensive' organs such as stems may be decoupled, with resistance in leaves acting as a bottleneck or 'safety valve'. We tested the HSH in woody species from a Mediterranean-type ecosystem by measuring leaf hydraulic conductance (Kleaf) and stem hydraulic conductivity (KS). We also investigated whether leaves function as safety valves by relating Kleaf and the hydraulic safety margin (stem water potential minus the water potential at which 50% of conductivity is lost (Ψstem-Ψ50)). We also examined related plant traits including the operating range of water potentials, wood density, leaf mass per area, and leaf area to sapwood area ratio to provide insight into whole-plant water use strategies. For hydrated shoots, Kleaf was negatively correlated with KS , supporting the HSH. Additionally, Kleaf was positively correlated with the hydraulic safety margin and negatively correlated with the leaf area to sapwood area ratio. Consistent with the HSH, our data indicate that leaves may act as control valves for species with high KS , or a low safety margin. This critical role of leaves appears to contribute importantly to plant ecological specialization in a drought-prone environment.

  3. Sensitivity study on hydraulic well testing inversion using simulated annealing

    Energy Technology Data Exchange (ETDEWEB)

    Nakao, Shinsuke; Najita, J.; Karasaki, Kenzi

    1997-11-01

    For environmental remediation, management of nuclear waste disposal, or geothermal reservoir engineering, it is very important to evaluate the permeabilities, spacing, and sizes of the subsurface fractures which control ground water flow. Cluster variable aperture (CVA) simulated annealing has been used as an inversion technique to construct fluid flow models of fractured formations based on transient pressure data from hydraulic tests. A two-dimensional fracture network system is represented as a filled regular lattice of fracture elements. The algorithm iteratively changes an aperture of cluster of fracture elements, which are chosen randomly from a list of discrete apertures, to improve the match to observed pressure transients. The size of the clusters is held constant throughout the iterations. Sensitivity studies using simple fracture models with eight wells show that, in general, it is necessary to conduct interference tests using at least three different wells as pumping well in order to reconstruct the fracture network with a transmissivity contrast of one order of magnitude, particularly when the cluster size is not known a priori. Because hydraulic inversion is inherently non-unique, it is important to utilize additional information. The authors investigated the relationship between the scale of heterogeneity and the optimum cluster size (and its shape) to enhance the reliability and convergence of the inversion. It appears that the cluster size corresponding to about 20--40 % of the practical range of the spatial correlation is optimal. Inversion results of the Raymond test site data are also presented and the practical range of spatial correlation is evaluated to be about 5--10 m from the optimal cluster size in the inversion.

  4. Abrasion test of flexible protective materials on hydraulic structures

    Directory of Open Access Journals (Sweden)

    Xin WANG

    2014-01-01

    Full Text Available In this study, several kinds of flexible protective materials sprayed with polyurea elastomers (hereinafter referred to as polyurea elastomer protective material were adopted to meet the abrasion resistance requirement of hydraulic structures, and their abrasion resistances against the water flow with suspended load or bed load were studied systematically through tests. Natural basalt stones were adopted as the abrasive for simulation of the abrasion effect of the water flow with bed load, and test results indicate that the basalt stone is suitable for use in the abrasion resistance test of the flexible protective material. The wear process of the polyurea elastomer protective material is stable, and the wear loss is linear with the time of abrasion. If the wear thickness is regarded as the abrasion resistance evaluation factor, the abrasion resistance of the 351 pure polyurea is about twice those of pure polyurea with a high level of hardness and aliphatic polyurea, and over five times that of high-performance abrasion-resistant concrete under the abrasion of the water flow with suspended load. It is also about 50 times that of high-performance abrasion-resistant concrete under the abrasion of the water flow with bed load. Overall, the abrasion resistance of pure polyurea presented a decreasing trend with increasing hardness. Pure polyurea with a Shore hardness of D30 has the best abrasion resistance, which is 60 to 70 times that of high-performance abrasion-resistant concrete under the abrasion of the water flow with bed load, and has been recommended, among the five kinds of pure polyurea materials with different hardness, in anti-abrasion protection of hydraulic structures.

  5. Research and implementation of the burst-mode optical signal bit-error test

    Science.gov (United States)

    Huang, Qiu-yuan; Ma, Chao; Shi, Wei; Chen, Wei

    2009-08-01

    On the basis of the characteristic of TDMA uplink optical signal of PON system, this article puts forward a method of high-speed optical burst bit-error rate testing based on FPGA. The article proposes a new method of generating the burst signal pattern include user-defined pattern and pseudo-random pattern, realizes the slip synchronization, self-synchronization of error detection using data decomposition technique and the traditional irrigation code synchronization technology, completes high-speed burst signal clock synchronization using the rapid synchronization technology of phase-locked loop delay in the external circuit and finishes the bit-error rate test of high-speed burst optical signal.

  6. Wave Dragon. Test to evaluate hydraulic response. Report phase A

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, H.C.; Friis-Madsen, E.

    1999-02-01

    Danish Maritime Institute has in the spring 1998 built a model in scale 1:50 of the wave energy converter Wave Dragon. The scale model is based on calculations performed by the inventor Erik Friis-Madsen from the consultant Loewenmark F.R.I. The scale model is tested in the wave tank at Aalborg University, the Hydraulic and Coastal Engineering Laboratory. This report deals with the results from this test (phase A of the test program). The objective of the test series was to get a judgement of the viability of Wave Dragon in extreme sea conditions in the Danish part of the North Sea at a water depth of 30 meters. The test series had to document: The viability of the Wave Dragon in extreme sea conditions up to 100-year waves; the hydraulic response in 7 different sea conditions where forces and movements have been registered. The main findings are: Wave Dragon has the expected behavior, i.e. the converter is able to survive a 100-year storm; An adjustment of the pitch of the converter could improve the energy efficiency; The forces in the mooring system and the junction between wave reflectors and the platform are acceptable. The forces and the movements are registered at 7 different sea conditions. Video recording has been taken during the test. Five of the sea conditions correspond to 'normal' waves in which power will be produced. Two sea conditions correspond to extreme wave situations. The duration of the registration in each sea conditions was approximately 1/2 an hour, i.e. 3.5 hours in scale 1:1. The conclusion is: The planned test series to evaluate the energy performance can start up (phase B of the test program); The energy efficiency is expected to be improved by a slight modification in the geometry of the Wave Dragon. The modifications can include the geometry of the front and the stabilising wing at the rear end of the platform. Further on changes are possible in the stiffness of the junction between the wave reflectors and the platform and

  7. Testing an unifying view of Gamma Ray Burst afterglows

    CERN Document Server

    Nardini, M; Ghirlanda, G; Celotti, A

    2009-01-01

    Four years after the launch the Swift satellite the nature of the Gamma Ray Bursts (GRBs) broadband afterglow behaviour is still an open issue ad the standard external shock fireball models cannot easily explain the puzzling combined temporal and spectral optical to X-ray behaviour of a large number of afterglows. We analysed the rest frame de-absorbed and K- corrected optical and X-ray multi-wavelength light-curves of a sample of 33 GRBs with known redshift and optical extinction at the host frame. We modelled their broadband behaviour as the sum of the standard forward shock emission due to the interaction of a fireball with the circum-burst medium and an additional component. We are able to obtain a good agreement with the observed light-curves despite their complexity and diversity and can also account for the lack of achromatic late times jet breaks in several GRBs and explain the presence of chromatic breaks. Even if the second component is treated in a phenomenological way, we can identify it as a "lat...

  8. Engineered Barrier Systems Thermal-Hydraulic-Chemical Column Test Report

    Energy Technology Data Exchange (ETDEWEB)

    W.E. Lowry

    2001-12-13

    The Engineered Barrier System (EBS) Thermal-Hydraulic-Chemical (THC) Column Tests provide data needed for model validation. The EBS Degradation, Flow, and Transport Process Modeling Report (PMR) will be based on supporting models for in-drift THC coupled processes, and the in-drift physical and chemical environment. These models describe the complex chemical interaction of EBS materials, including granular materials, with the thermal and hydrologic conditions that will be present in the repository emplacement drifts. Of particular interest are the coupled processes that result in mineral and salt dissolution/precipitation in the EBS environment. Test data are needed for thermal, hydrologic, and geochemical model validation and to support selection of introduced materials (CRWMS M&O 1999c). These column tests evaluated granular crushed tuff as potential invert ballast or backfill material, under accelerated thermal and hydrologic environments. The objectives of the THC column testing are to: (1) Characterize THC coupled processes that could affect performance of EBS components, particularly the magnitude of permeability reduction (increases or decreases), the nature of minerals produced, and chemical fractionation (i.e., concentrative separation of salts and minerals due to boiling-point elevation). (2) Generate data for validating THC predictive models that will support the EBS Degradation, Flow, and Transport PMR, Rev. 01.

  9. ENERGY EFFICIENCY OF DIESEL LOCOMOTIVE HYDRAULIC TRANSMISSION TESTS AT LOCOMOTIVE REPAIR PLANT

    Directory of Open Access Journals (Sweden)

    B. E. Bodnar

    2015-10-01

    Full Text Available Purpose. In difficult economic conditions, cost reduction of electricity consumption for the needs of production is an urgent task for the country’s industrial enterprises. Technical specifications of enterprises, which repair diesel locomotive hydraulic transmission, recommend conducting a certain amount of evaluation and regulatory tests to monitor their condition after repair. Experience shows that a significant portion of hydraulic transmission defects is revealed by bench tests. The advantages of bench tests include the ability to detect defects after repair, ease of maintenance of the hydraulic transmission and relatively low labour intensity for eliminating defects. The quality of these tests results in the transmission resource and its efficiency. Improvement of the technology of plant post-repairs hydraulic tests in order to reduce electricity consumption while testing. Methodology. The possible options for hydraulic transmission test bench improvement were analysed. There was proposed an energy efficiency method for diesel locomotive hydraulic transmission testing in locomotive repair plant environment. This is achieved by installing additional drive motor which receives power from the load generator. Findings. Based on the conducted analysis the necessity of improving the plant stand testing of hydraulic transmission was proved. The variants of the stand modernization were examined. The test stand modernization analysis was conducted. Originality. The possibility of using electric power load generator to power the stand electric drive motor or the additional drive motor was theoretically substantiated. Practical value. A variant of hydraulic transmission test stand based on the mutual load method was proposed. Using this method increases the hydraulic transmission load range and power consumption by stand remains unchanged. The additional drive motor will increase the speed of the input shaft that in its turn wil allow testing in

  10. Hydraulic testing of low-permeability Silurian and Ordovician strata, Michigan Basin, southwestern Ontario

    Science.gov (United States)

    Beauheim, Richard L.; Roberts, Randall M.; Avis, John D.

    2014-02-01

    Straddle-packer hydraulic testing was performed in 31 Silurian intervals and 66 Ordovician intervals in six deep boreholes at the Bruce nuclear site, located near Tiverton, Ontario, as part of site-characterization activities for a proposed deep geologic repository (DGR) for low- and intermediate-level radioactive waste. The straddle-packer assembly incorporated a hydraulic piston to initiate in situ pulse tests within low hydraulic conductivity (condition and relative to the overlying Silurian strata and underlying Black River Group and Cambrian strata. These underpressures could not persist if hydraulic conductivities were not as low as those measured.

  11. Solid Rocket Booster Hydraulic Pump Port Cap Joint Load Testing

    Science.gov (United States)

    Gamwell, W. R.; Murphy, N. C.

    2004-01-01

    The solid rocket booster uses hydraulic pumps fabricated from cast C355 aluminum alloy, with 17-4 PH stainless steel pump port caps. Corrosion-resistant steel, MS51830 CA204L self-locking screw thread inserts are installed into C355 pump housings, with A286 stainless steel fasteners installed into the insert to secure the pump port cap to the housing. In the past, pump port cap fasteners were installed to a torque of 33 Nm (300 in-lb). However, the structural analyses used a significantly higher nut factor than indicated during tests conducted by Boeing Space Systems. When the torque values were reassessed using Boeing's nut factor, the fastener preload had a factor of safety of less than 1, with potential for overloading the joint. This paper describes how behavior was determined for a preloaded joint with a steel bolt threaded into steel inserts in aluminum parts. Finite element models were compared with test results. For all initial bolt preloads, bolt loads increased as external applied loads increased. For higher initial bolt preloads, less load was transferred into the bolt, due to external applied loading. Lower torque limits were established for pump port cap fasteners and additional limits were placed on insert axial deformation under operating conditions after seating the insert with an initial preload.

  12. Commissioning of the ATLAS thermal-hydraulic integral test facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yeon-Sik [Thermal Hydraulics Safety Research Division, Korea Atomic Energy Research Institute, 1045 Daedeokdaero, Yuseong-gu, Daejeon 305-353 (Korea, Republic of)], E-mail: yskim3@kaeri.re.kr; Choi, Ki-Yong; Park, Hyeon-Sik; Cho, Seok; Kim, Bok-Deug; Choi, Nam-Hyeon; Baek, Won-Pil [Thermal Hydraulics Safety Research Division, Korea Atomic Energy Research Institute, 1045 Daedeokdaero, Yuseong-gu, Daejeon 305-353 (Korea, Republic of)

    2008-10-15

    KAERI recently constructed a new thermal-hydraulic integral test facility for advanced pressurized water reactors (PWRs) - ATLAS. The ATLAS facility has the following characteristics: (a) 1/2-height and length, 1/288-volume, and full pressure simulation of APR1400, (b) maintaining a geometrical similarity with APR1400 including 2(hot legs) x 4(cold legs) reactor coolant loops, direct vessel injection (DVI) of emergency core cooling water, integrated annular downcomer, etc., (c) incorporation of specific design characteristics of OPR1000 such as cold leg injection and low-pressure safety injection pumps, (d) maximum 10% of the scaled nominal core power. The ATLAS will mainly be used to simulate various accident and transient scenarios for evolutionary PWRs, OPR1000 and APR1400: the simulation capability of broad scenarios including the reflood phase of a large-break loss-of-coolant accident (LOCA), small-break LOCA scenarios including DVI line breaks, a steam generator tube rupture, a main steam line break, a feed line break, a mid-loop operation, etc. The ATLAS is now in operation after an extensive series of commissioning tests in 2006.

  13. KJRR-FAI Hydraulic Flow Testing Input Package

    Energy Technology Data Exchange (ETDEWEB)

    N.E. Woolstenhulme; R.B. Nielson; D.B. Chapman

    2013-12-01

    The INL, in cooperation with the KAERI via Cooperative Research And Development Agreement (CRADA), undertook an effort in the latter half of calendar year 2013 to produce a conceptual design for the KJRR-FAI campaign. The outcomes of this effort are documented in further detail elsewhere [5]. The KJRR-FAI was designed to be cooled by the ATR’s Primary Coolant System (PCS) with no provision for in-pile measurement or control of the hydraulic conditions in the irradiation assembly. The irradiation assembly was designed to achieve the target hydraulic conditions via engineered hydraulic losses in a throttling orifice at the outlet of the irradiation vehicle.

  14. In-Plant Testing of High-Efficiency Hydraulic Separators

    Energy Technology Data Exchange (ETDEWEB)

    G. H. Luttrell; R. Q. Honaker; R. C. Bratton; T. C. Westerfield; J. N. Kohmuench

    2004-07-20

    The mineral processing industry has commonly utilized hydraulic separators throughout history for classification and gravity concentration of various minerals. More commonly referred to as hindered-bed or fluidized-bed separators, these units make use of differential particle settling rates to segregate particles according to shape, size, and/or density. As with any equipment, there are inefficiencies associated with its operation, which prompted an industry driven research program to further evaluate two novel high-efficiency hindered bed separators. These units, which are commercially called the CrossFlow separator and HydroFloat separator, have the potential to improve performance (separation efficiency and throughput) and reduce operating costs (power consumption, water and reagent usage). This report describes the results of Phase I activities (laboratory and pilot-scale tests) conducted with the CrossFlow and HydroFloat separators at several locations in the minerals and coal industries. Details of the testing programs (equipment setup, shakedown testing and detailed testing) associated with four coal plants and two phosphate plants are summarized in this work. In most of these applications, the high-efficiency units proved to provide a higher quality product at reduced costs when compared against the performance of conventional separators. Based on promising results obtained from Phase I, full-scale prototypes will be purchased by several mining companies for use in Phase II of this project. Two of the prototype units, which will be constructed by Eriez Manufacturing, are expected to be installed by a major U.S. phosphate producer and a large eastern U.S. coal company. Negotiations are also underway to purchase and install additional prototype units by a mineral sands producer and a second phosphate producer. The data obtained from the full-scale evaluations will be used to further promote commercialization and industrial applications of these innovative

  15. Test program element II blanket and shield thermal-hydraulic and thermomechanical testing, experimental facility survey

    Energy Technology Data Exchange (ETDEWEB)

    Ware, A.G.; Longhurst, G.R.

    1981-12-01

    This report presents results of a survey conducted by EG and G Idaho to determine facilities available to conduct thermal-hydraulic and thermomechanical testing for the Department of Energy Office of Fusion Energy First Wall/Blanket/Shield Engineering Test Program. In response to EG and G queries, twelve organizations (in addition to EG and G and General Atomic) expressed interest in providing experimental facilities. A variety of methods of supplying heat is available.

  16. The emission of Gamma Ray Bursts as a test-bed for modified gravity

    Energy Technology Data Exchange (ETDEWEB)

    Capozziello, S., E-mail: capozziello@na.infn.it [Dipartimento di Fisica, Universitá di Napoli “Federico II”, Via Cinthia, I-80126, Napoli (Italy); INFN Sez. di Napoli, Compl. Univ. di Monte S. Angelo, Edificio G, Via Cinthia, I-80126, Napoli (Italy); Gran Sasso Science Institute (INFN), Via F. Crispi 7, I-67100, L' Aquila (Italy); Lambiase, G. [Dipartimento di Fisica “E.R. Caianiello”, Universitá di Salerno, I-84084, Fisciano (Italy); INFN – Gruppo Collegato di Salerno (Italy)

    2015-11-12

    The extreme physical conditions of Gamma Ray Bursts can constitute a useful observational laboratory to test theories of gravity where very high curvature regimes are involved. Here we propose a sort of curvature engine capable, in principle, of explaining the huge energy emission of Gamma Ray Bursts. Specifically, we investigate the emission of radiation by charged particles non-minimally coupled to the gravitational background where higher order curvature invariants are present. The coupling gives rise to an additional force inducing a non-geodesic motion of particles. This fact allows a strong emission of radiation by gravitationally accelerated particles. As we will show with some specific model, the energy emission is of the same order of magnitude of that characterizing the Gamma Ray Burst physics. Alternatively, strong curvature regimes can be considered as a natural mechanism for the generation of highly energetic astrophysical events. Possible applications to cosmology are discussed.

  17. The emission of Gamma Ray Bursts as a test-bed for modified gravity

    Directory of Open Access Journals (Sweden)

    S. Capozziello

    2015-11-01

    Full Text Available The extreme physical conditions of Gamma Ray Bursts can constitute a useful observational laboratory to test theories of gravity where very high curvature regimes are involved. Here we propose a sort of curvature engine capable, in principle, of explaining the huge energy emission of Gamma Ray Bursts. Specifically, we investigate the emission of radiation by charged particles non-minimally coupled to the gravitational background where higher order curvature invariants are present. The coupling gives rise to an additional force inducing a non-geodesic motion of particles. This fact allows a strong emission of radiation by gravitationally accelerated particles. As we will show with some specific model, the energy emission is of the same order of magnitude of that characterizing the Gamma Ray Burst physics. Alternatively, strong curvature regimes can be considered as a natural mechanism for the generation of highly energetic astrophysical events. Possible applications to cosmology are discussed.

  18. Combining 3D Hydraulic Tomography with Tracer Tests for Improved Transport Characterization.

    Science.gov (United States)

    Sanchez-León, E; Leven, C; Haslauer, C P; Cirpka, O A

    2016-07-01

    Hydraulic tomography (HT) is a method for resolving the spatial distribution of hydraulic parameters to some extent, but many details important for solute transport usually remain unresolved. We present a methodology to improve solute transport predictions by combining data from HT with the breakthrough curve (BTC) of a single forced-gradient tracer test. We estimated the three dimensional (3D) hydraulic-conductivity field in an alluvial aquifer by inverting tomographic pumping tests performed at the Hydrogeological Research Site Lauswiesen close to Tübingen, Germany, using a regularized pilot-point method. We compared the estimated parameter field to available profiles of hydraulic-conductivity variations from direct-push injection logging (DPIL), and validated the hydraulic-conductivity field with hydraulic-head measurements of tests not used in the inversion. After validation, spatially uniform parameters for dual-domain transport were estimated by fitting tracer data collected during a forced-gradient tracer test. The dual-domain assumption was used to parameterize effects of the unresolved heterogeneity of the aquifer and deemed necessary to fit the shape of the BTC using reasonable parameter values. The estimated hydraulic-conductivity field and transport parameters were subsequently used to successfully predict a second independent tracer test. Our work provides an efficient and practical approach to predict solute transport in heterogeneous aquifers without performing elaborate field tracer tests with a tomographic layout.

  19. Research on the improvement of nuclear safety -Thermal hydraulic tests for reactor safety system-

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Moon Kee; Park, Choon Kyung; Yang, Sun Kyoo; Chun, Se Yung; Song, Chul Hwa; Jun, Hyung Kil; Jung, Heung Joon; Won, Soon Yun; Cho, Yung Roh; Min, Kyung Hoh; Jung, Jang Hwan; Jang, Suk Kyoo; Kim, Bok Deuk; Kim, Wooi Kyung; Huh, Jin; Kim, Sook Kwan; Moon, Sang Kee; Lee, Sang Il [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-06-01

    The present research aims at the development of the thermal hydraulic verification test technology for the safety system of the conventional and advanced nuclear power plant and the development of the advanced thermal hydraulic measuring techniques. In this research, test facilities simulating the primary coolant system and safety system are being constructed for the design verification tests of the existing and advanced nuclear power plant. 97 figs, 14 tabs, 65 refs. (Author).

  20. Development of realistic thermal-hydraulic system analysis codes ; development of thermal hydraulic test requirements for multidimensional flow modeling

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Kune Yull; Yoon, Sang Hyuk; Noh, Sang Woo; Lee, Il Suk [Seoul National University, Seoul (Korea)

    2002-03-01

    This study is concerned with developing a multidimensional flow model required for the system analysis code MARS to more mechanistically simulate a variety of thermal hydraulic phenomena in the nuclear stem supply system. The capability of the MARS code as a thermal hydraulic analysis tool for optimized system design can be expanded by improving the current calculational methods and adding new models. In this study the relevant literature was surveyed on the multidimensional flow models that may potentially be applied to the multidimensional analysis code. Research items were critically reviewed and suggested to better predict the multidimensional thermal hydraulic behavior and to identify test requirements. A small-scale preliminary test was performed in the downcomer formed by two vertical plates to analyze multidimensional flow pattern in a simple geometry. The experimental result may be applied to the code for analysis of the fluid impingement to the reactor downcomer wall. Also, data were collected to find out the controlling parameters for the one-dimensional and multidimensional flow behavior. 22 refs., 40 figs., 7 tabs. (Author)

  1. Design and Experiment of Electronic-hydraulic Loading Test-bed Based on Tractor’s Hydraulic Steering By-wire

    Institute of Scientific and Technical Information of China (English)

    Yue JIN; Yang LU; Jiahui GONG; Zhixiong LU; Wenming LI; Jungan WU

    2015-01-01

    An Electro-hydraulic loading system is designed based on a test-bed of tractor’s hydraulic steering by-wire. To simulate the steering resistance driving tractor in many kinds of soils and roads,the loading force is controlled to make proportional and continuous variable by an electro-hydraulic proportional relief valve. A steering resistance loading test-bed is built to test three kinds of steering resistance including constant,step and sine style. Tire lateral resistance is also tested under different steering conditions. The result shows that the electro-hydraulic loading system has high stability and following performance. Besides,the system’s steady state error is lower than 3. 1%,and it meets the test requirement of tractor’s hydraulic steering by-wire.

  2. Testing and Performance of UFFO Burst Alert & Trigger Telescope

    DEFF Research Database (Denmark)

    Rípa, Jakub; Bin Kim, Min; Lee, Jik

    2014-01-01

    telescope (UBAT) employing the coded mask imaging technique and the detector combination of Yttrium Oxyorthosilicate (YSO) scintillating crystals and multi-anode photomultiplier tubes. The results of the laboratory tests of UBAT’s functionality and performance are described in this article. The detector...

  3. The Hydraulic Test Procedure for Non-instrumented Irradiation Test Rig of Annular Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Ho; Lee, Kang Hee; Shin, Chang Hwan; Park, Chan Kook

    2008-08-15

    This report presents the procedure of pressure drop test, vibration test and endurance test for the non-instrumented rig using the irradiation test in HANARO of advanced PWR annular fuel which were designed and fabricated by KAERI. From the out-pile thermal hydraulic tests, confirm the flow rate at the 200 kPa pressure drop and measure the RMS displacement at this time. And the endurance test is confirmed the wear and the integrity of the non-instrumented rig at the 110% design flow rate. This out-pile test perform the Flow-Induced Vibration and Pressure Drop Experimental Tester(FIVPET) facility. The instruments in FIVPET facility was calibrated in KAERI and the pump and the thermocouple were certified by manufacturer.

  4. Spatial variability of hydraulic conductivity of an unconfined sandy aquifer determined by a mini slug test

    DEFF Research Database (Denmark)

    Bjerg, Poul Løgstrup; Hinsby, Klaus; Christensen, Thomas Højlund;

    1992-01-01

    The spatial variability of the hydraulic conductivity in a sandy aquifer has been determined by a mini slug test method. The hydraulic conductivity (K) of the aquifer has a geometric mean of 5.05 × 10−4 m s−1, and an overall variance of 1n K equal to 0.37 which corresponds quite well to the results...... obtained by two large scale tracer experiments performed in the aquifer. A geological model of the aquifer based on 31 sediment cores, proposed three hydrogeological layers in the aquifer concurrent with the vertical variations observed with respect to hydraulic conductivity. The horizontal correlation...... length of the hydraulic conductivity has been determined for each of the three hydrogeological layers and is found to be small (1–2.5 m). The asymptotic longitudinal dispersivity of the aquifer has been estimated from the variance in hydraulic conductivity and the horizontal correlation length...

  5. Design of hydraulic active stabilizer bar test platform based on dSPACE

    Directory of Open Access Journals (Sweden)

    Shan CHEN

    2016-12-01

    Full Text Available For the study of the influence of hydraulic active stabilizer bar to vehicle lateral stability under high speed steering maneuver, the hydraulic active stabilizer bar HIL test platform is implemented. The HIL test platform is designed with single/double axles universal test bench to experiment on single or double axles active stabilizer bar, using MC9S12DG128 microcontroller as the core controller and running vehicle dynamics model in the dSPACE. This HIL platform is used to study the effect of the hydraulic active stabilizer bar on the vehicle roll stability under different types of the road and typical steering maneuvers. The experiment results illustrate that the hydraulic active stabilizer bar HIL test platform can simulate the experiment environment and provide a powerful support for the development of active stabilizer bar system.

  6. Mechanical testing of hydraulic fluids II; Mechanische Pruefung von Hydraulikfluessigkeiten II

    Energy Technology Data Exchange (ETDEWEB)

    Kessler, M.; Feldmann, D.G.; Laukart, V.

    2001-09-01

    Since May 1996 the Institute for Mechanical Engineering Design 1 of Technical University of Hamburg-Harburg is working on the topic of ''Mechanical Testing of Hydraulic fluids''. The first project lasting 2 1/2 years was completed in 1999, the results are published as the DGMK report 514. Within these project a testing principle for the ''mechanical testing'' of hydraulic fluids has been derived, a prototype of a test rig was designed and set in operation at the authors' institute. This DGMK-report 514-1 describes the results of the second project, which investigates the operating behaviour of the test-rig more in detail. Several test-runs with a total number of 11 different hydraulic fluids show the dependence of the different lubricating behaviour of the tested fluids and their friction and wear behaviour during the tests in a reproducible way. The aim of the project was to derive a testing principle including the design of a suitable test-rig for the mechanical testing of hydraulic fluids. Based on the described results it can be stated that with the developed test it is possible to test the lubricity of hydraulic fluids reproducible and in correlation to field experiences within a relatively short time, so the target was reached. (orig.)

  7. Simulation of a spatial, servo-hydraulic test facility for space structures

    Science.gov (United States)

    Leimbach, K.-D.; Hahn, H.

    1994-01-01

    In this paper different control concepts for servo-hydraulic test facilities are derived using exact linearization techniques. Based on different linear and nonlinear models of the test table and the actuator dynamics several nonlinear controllers of different complexity are derived. The closed loop system performance of the controlled servo-hydraulic test facility is tested in various computer simulations using both, standard test signals and large test signals as system inputs. The simulation results turn out, that in case of standard input signals the test facility controller must include a linear test table mechanics model and a nonlinear servo-hydraulic actuator model. Additional simulations demonstrate the robustness of the control concept selected for standard test signals with respect to variations of plant parameters.

  8. Development and industrial tests of the first LNG hydraulic turbine system in China

    Directory of Open Access Journals (Sweden)

    Jie Chen

    2016-10-01

    Full Text Available The cryogenic hydraulic turbine can be used to replace the conventional J–T valve for LNG or mixed refrigerant throttling and depressurization in a natural gas liquefaction plant. This advanced technology is not only to enhance the efficiency of the liquefaction plant, but to usher a new trend in the development of global liquefaction technologies. China has over 136 liquefaction plants, but the cryogenic hydraulic turbines have not been deployed in industrial utilization. In addition, these turbines cannot be manufactured domestically. In this circumstance, through working on the key technologies for LNG hydraulic turbine process & control system development, hydraulic model optimization design, structure design and manufacturing, the first domestic cryogenic hydraulic turbine with a flow rate of 40 m3/h was developed to recover the pressure energy from the LNG of cold box. The turbine was installed in the CNOOC Zhuhai Natural Gas Liquefaction Plant for industrial tests under multiple working conditions, including start-stop, variable flow rates and variable rotation speeds. Test results show that the domestic LNG cryogenic hydraulic turbine has satisfactory mechanical and operational performances at low temperatures as specified in design. In addition, the process & control system and frequency-conversion power-generation system of the turbine system are designed properly to automatically and smoothly replace the existing LNG J–T valve. As a result, the domestic LNG cryogenic hydraulic turbine system can improve LNG production by an average of 2% and generate power of 8.3 kW.

  9. In-situ stress from hydraulic fracture measurements in G Tunnel, Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Smith, C.; Vollendorf, W. C.; Warren, W. E.

    1981-04-01

    Hydraulic fracture work in G Tunnel, Nevada Test Site, performed to obtain the in-situ stress state is discussed. Field equipment and procedures are described; analysis is developed to relate the hydraulic fracture pressures to the in-situ stress state. Pressure data are analyzed to provide estimates of the stress state at a number of locations in the tunnel complex. A unique feature of the work is the mineback - a mining process in which the rock is cut away to reveal the actual plane of the fracture. Advantages, limitations, and problem areas associated with extracting in-situ stress fields from hydraulic fracture pressure records are discussed in detail.

  10. Hazards and Safeguards of High Pressure Hydraulic Fatigue Testing

    Science.gov (United States)

    1990-07-01

    rew e I&64aN neem mde tliF by block mumber) The creation and transfer of hydraulic pressure at the 690-MPa (100,000-psi) level is in itself hazardous...than alloy steel, we have found that it is more notch sensitive to fatigue and drastically degrades with small constituent variations. To avoid this...I ATTN: SMCWV-PP DIRECTOR, PRODUCT ASSURANCE DIRECTORATE 1 ATTN: SMCWV-QA NOTE: PLEASE NOTIFY DIRECTOR, BENET LABORATORIES, ATTN: SMCAR-CCB-TL, OF ANY

  11. Testing Einstein's Equivalence Principle with Cosmological Fast Radio Bursts behind Clusters of Galaxies

    CERN Document Server

    Zhang, Shuang-Nan

    2016-01-01

    Aims: Recently, cosmological fast radio bursts (FRBs) have been used to provide the most stringent limit up to date on Einstein's Equivalence Principle (EEP). We study how to further test EEP with FRBs. Methods: Future systematic radio surveys will certainly find abundant FRBs at cosmological distances and some of them will inevitably be located behind clusters of galaxies. Here we suggest to use those FRBs to further test EEP. Results: We find that the robustness and accuracy of testing EEP can be improved further by orders of magnitude with these FRBs. The same methodology can also be applied to any other types of fast and bright transients at cosmological distances.

  12. Burst and inter-burst duration statistics as empirical test of long-range memory in the financial markets

    Science.gov (United States)

    Gontis, V.; Kononovicius, A.

    2017-10-01

    We address the problem of long-range memory in the financial markets. There are two conceptually different ways to reproduce power-law decay of auto-correlation function: using fractional Brownian motion as well as non-linear stochastic differential equations. In this contribution we address this problem by analyzing empirical return and trading activity time series from the Forex. From the empirical time series we obtain probability density functions of burst and inter-burst duration. Our analysis reveals that the power-law exponents of the obtained probability density functions are close to 3 / 2, which is a characteristic feature of the one-dimensional stochastic processes. This is in a good agreement with earlier proposed model of absolute return based on the non-linear stochastic differential equations derived from the agent-based herding model.

  13. Measuring the initial earth pressure of granite using hydraulic fracturing test; Goseong and Yuseong areas

    Energy Technology Data Exchange (ETDEWEB)

    Park, Byoung Yoon; Bae, Dae Seok; Kim, Chun Soo; Kim, Kyung Su; Koh, Young Kwon; Won, Kyung Sik [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2002-02-01

    This report provides the initial earth pressure of granitic rocks obtained from Deep Core Drilling Program which is carried out as part of the assessment of deep geological environmental condition. These data are obtained by hydraulic fracturing test in three boreholes drilled up to 350{approx}500 m depth at the Yuseong and Goseong sites. These sites were selected based on the result of preliminary site evaluation study. The boreholes are NX-size (76 mm) and vertical. The procedure of hydraulic fracturing test is as follows: - Selecting the testing positions by preliminary investigation using BHTV logging. - Performing the hydraulic fracturing test at each selected position with depth.- Estimating the shut-in pressure by the bilinear pressure-decay-rate method. - Estimating the fracture reopening pressure from the pressure-time curves.- Estimating the horizontal principal stresses and the direction of principal stresses. 65 refs., 39 figs., 12 tabs. (Author)

  14. PILOT-SCALE HYDRAULIC TESTING OF RESORCINOL FORMALDEHYDE ION EXCHANGE RESIN

    Energy Technology Data Exchange (ETDEWEB)

    Adamson, D.

    2009-05-28

    Savannah River National Laboratory (SRNL) performed pilot-scale hydraulic/chemical testing of spherical resorcinol formaldehyde (RF) ion exchange (IX) resin for the River Protection Project-Hanford Tank Waste Treatment & Immobilization Plant (WTP) Project. The RF resin hydraulic cycle testing was conducted in two pilot-scale IX columns, 1/4 and 1/2 scale. A total of twenty-three hydraulic/chemical cycles were successfully completed on the spherical RF resin. Sixteen of these cycles were completed in the 24-inch IX Column (1/2 scale column). Hydraulic testing showed that the permeability of the RF resin remained essentially constant, with no observed trend in the reduction of the permeability as the number of cycles increased. The permeability during the pilot-scale testing was 3 times better than the design requirements of the WTP full-scale IX system. The RF resin bed showed no tendency to form fissures or pack more densely as the number of cycles increased. Particle size measurements of the RF resin showed no indication of particle size change (for a given chemical) with cycles and essentially no fines formation. The permeability of the resin bed was uniform with respect to changes in bed depth. Upflow Regeneration and Simulant Introduction in the IX columns revealed another RF resin benefit; negligible radial pressures to the column walls from the swelling of resin beads. The hydraulic and chemical performance of the spherical RF resin during cycle testing was found to be superior to all other tested IX resins. The pilot-scale testing indicates that the RF resin is durable and should hold up to many hydraulic cycles in actual radioactive Cesium (Cs) separation.

  15. Hydraulic testing of Salado Formation evaporites at the Waste Isolation Pilot Plant site: Second interpretive report

    Energy Technology Data Exchange (ETDEWEB)

    Beauheim, R.L. [Sandia National Labs., Albuquerque, NM (United States); Roberts, R.M.; Dale, T.F.; Fort, M.D.; Stensrud, W.A. [INTERA, Inc., Austin, TX (United States)

    1993-12-01

    Pressure-pulse, constant-pressure flow, and pressure-buildup tests have been performed in bedded evaporites of the Salado Formation at the Waste Isolation Pilot Plant (WIPP) site to evaluate the hydraulic properties controlling brine flow through the Salado. Transmissivities have been interpreted from six sequences of tests conducted on five stratigraphic intervals within 15 m of the WIPP underground excavations.

  16. Testing the suitability of geologic frameworks for extrapolating hydraulic properties across regional scales

    Science.gov (United States)

    Mirus, Benjamin B.; Halford, Keith; Sweetkind, Don; Fenelon, Joe

    2016-08-01

    The suitability of geologic frameworks for extrapolating hydraulic conductivity ( K) to length scales commensurate with hydraulic data is difficult to assess. A novel method is presented for evaluating assumed relations between K and geologic interpretations for regional-scale groundwater modeling. The approach relies on simultaneous interpretation of multiple aquifer tests using alternative geologic frameworks of variable complexity, where each framework is incorporated as prior information that assumes homogeneous K within each model unit. This approach is tested at Pahute Mesa within the Nevada National Security Site (USA), where observed drawdowns from eight aquifer tests in complex, highly faulted volcanic rocks provide the necessary hydraulic constraints. The investigated volume encompasses 40 mi3 (167 km3) where drawdowns traversed major fault structures and were detected more than 2 mi (3.2 km) from pumping wells. Complexity of the five frameworks assessed ranges from an undifferentiated mass of rock with a single unit to 14 distinct geologic units. Results show that only four geologic units can be justified as hydraulically unique for this location. The approach qualitatively evaluates the consistency of hydraulic property estimates within extents of investigation and effects of geologic frameworks on extrapolation. Distributions of transmissivity are similar within the investigated extents irrespective of the geologic framework. In contrast, the extrapolation of hydraulic properties beyond the volume investigated with interfering aquifer tests is strongly affected by the complexity of a given framework. Testing at Pahute Mesa illustrates how this method can be employed to determine the appropriate level of geologic complexity for large-scale groundwater modeling.

  17. Testing the suitability of geologic frameworks for extrapolating hydraulic properties across regional scales

    Science.gov (United States)

    Mirus, Benjamin B.; Halford, Keith J.; Sweetkind, Donald; Fenelon, Joseph M.

    2016-01-01

    The suitability of geologic frameworks for extrapolating hydraulic conductivity (K) to length scales commensurate with hydraulic data is difficult to assess. A novel method is presented for evaluating assumed relations between K and geologic interpretations for regional-scale groundwater modeling. The approach relies on simultaneous interpretation of multiple aquifer tests using alternative geologic frameworks of variable complexity, where each framework is incorporated as prior information that assumes homogeneous K within each model unit. This approach is tested at Pahute Mesa within the Nevada National Security Site (USA), where observed drawdowns from eight aquifer tests in complex, highly faulted volcanic rocks provide the necessary hydraulic constraints. The investigated volume encompasses 40 mi3 (167 km3) where drawdowns traversed major fault structures and were detected more than 2 mi (3.2 km) from pumping wells. Complexity of the five frameworks assessed ranges from an undifferentiated mass of rock with a single unit to 14 distinct geologic units. Results show that only four geologic units can be justified as hydraulically unique for this location. The approach qualitatively evaluates the consistency of hydraulic property estimates within extents of investigation and effects of geologic frameworks on extrapolation. Distributions of transmissivity are similar within the investigated extents irrespective of the geologic framework. In contrast, the extrapolation of hydraulic properties beyond the volume investigated with interfering aquifer tests is strongly affected by the complexity of a given framework. Testing at Pahute Mesa illustrates how this method can be employed to determine the appropriate level of geologic complexity for large-scale groundwater modeling.

  18. Hydraulic model tests on modified Wave Dragon. Phase 3

    Energy Technology Data Exchange (ETDEWEB)

    Hald, T.; Lynggaard, J.

    2002-11-01

    The purpose of this report is to describe the model tests conducted with a new designed 2. generation WD model as well as obtained model test results. Tests are conducted as sequential reconstruction followed by physical model tests. All details concerning the reconstruction are found in Hald and Lynggaard (2001). Model tests and reconstruction are carried out during the phase 3 project: 'Wave Dragon. Reconstruction of an existing model in scale 1:50 and sequential tests of changes to the model geometry and mass distribution parameters' sponsored by the Danish Energy Agency (DEA) wave energy programme. The tests will establish a well documented basis for the development of a 1:4.5 scale prototype planned for testing Nissum Bredning, a sea inlet on the Danish West Coast. (au)

  19. High speed cinematography of the initial break-point of latex condoms during the air burst test.

    Science.gov (United States)

    Stube, R; Voeller, B; Davidhazy, A

    1990-06-01

    High speed cinematography of latex condoms inflated to burst under standard (ISO) conditions reveals that rupture of the condom typically is initiated at a small focal point on the shank of the condom and then rapidly propagates throughout the condom's surface, often ending with partial or full severance of the condom at its point of attachment to the air burst instrument. This sequence of events is the reverse of that sometimes hypothesized to occur, where initiation of burst was considered to begin at the attachment point and to constitute a testing method artifact. This hypothesis of breakage at the attachment point, if true, would diminish the value of the air burst test as a standard for assessing manufacturing quality control as well as for condom strength measurements and comparisons.

  20. Hydraulic Conductivity Estimate via Tracer Test and Ensemble Kalman Filter Data Assimilation: Theoretical and Numerical Fundamentals

    Science.gov (United States)

    Crestani, E.; Camporese, M.; Salandin, P.

    2011-12-01

    Hydraulic properties of natural aquifers, such as porosity, hydraulic conductivity, and storativity, exhibit an erratic spatial variability at different scales that is difficult to recognize without expensive in situ sampling campaigns, laboratory analyses, and, when available, spatially distributed pumping tests. Nevertheless, the importance of the heterogeneous structure of natural formations on solute transport is well recognized, being the non-Fickian evolution of contaminant plumes and the relevant dispersive phenomena controlled by the variability of the hydraulic conductivity K at the local scale. Tracer test analyses have been widely adopted to identify the complex distribution of in situ hydraulic properties. In particular, the use of geophysical methods like the borehole Electrical Resistivity Tomography (ERT) have been in rapid increase, due to their potential to accurately describe the spatio-temporal evolution of the injected solute. Under the assumptions that the solute spreads as a passive tracer and with high values of the Peclet number, the plume evolution is controlled by the porosity and the spatial distribution of hydraulic conductivity. Combining the Lagrangian formulation of transport and the ensemble Kalman filter (EnKF) data assimilation technique, the purpose of this study is to infer the spatial distribution of K at the local scale from a sequence of time-lapse concentration imaging. The capabilities of the proposed approach are investigated simulating various assimilation experiments via synthetic tracer tests in a three-dimensional finite domain reproducing a heterogeneous aquifer. In a first scenario, all the available concentration measurements are assimilated and the entire hydraulic conductivity field is updated, while in the remaining scenarios the K values are updated only in a limited number of nodes by assimilating the concentrations in these same nodes, the hydraulic conductivity in the rest of the domain being the result of a

  1. Digital Measuring Devices Used for Injector Hydraulic Test

    Directory of Open Access Journals (Sweden)

    S. N. Leontiev

    2015-01-01

    Full Text Available To ensure a high specific impulse of the LRE (liquid-propellant engine chamber it is necessary to have optimally organized combustion of the fuel components. This can be ensured by choosing the optimum geometry of gas-dynamic contour of the LRE combustor, as well as by improving the sputtering processes and mixing the fuel components, for example, by selection of the optimum type, characteristics, and location of injectors on the mixing unit of the chamber.These particular reasons arise the interest in the injector characteristics in terms of science, and technological aspects determine the need for control of underlying design parameters in their manufacture.The objective of this work is to give an experimental justification on used digital measurement instrumentation and research the hydraulic characteristics of injectors.To determine injector parameters most widely were used the units with sectional collectors. A technique to control injector parameters using the sectional collectors involves spraying the liquid by injector at a given pressure drop on it for a certain time (the longer, the higher the accuracy and reliability of the results and then determining the amount of liquid in each section to calculate the required parameters of injector.In this work the liquid flow through the injector was determined by high-precision flowmeters FLONET FN2024.1 of electromagnetic type, which have very high metrological characteristics, in particular a flow rate error does not exceed 0.5% in a range of water flow from Qmin= 0.0028 l/s to Qmax Qmax = 0.28 l/s. To determine the coefficient of uneven spray were used differential pressure sensors DMD 331-ASLX of company "DB Sensors RUS", which have an error of 0.075% with a range of differential pressure 0 ... 5 kPa. Measuring complex MIC-200 of company "NPP Measure" and WinPos software for processing array information provided entry, recording, and processing of all the data of the experiment.In this

  2. Regional characterization of hydraulic properties of rock using well test data

    Energy Technology Data Exchange (ETDEWEB)

    Wladis, D.; Joensson, P.; Wallroth, T. [Chalmers Univ. of Technology., Goeteborg (Sweden). Dept. of Geology

    1997-11-01

    This study was aimed at investigating the possible use of data from the SGU well archive for characterization of the hydraulic properties of the crystalline basement of Sweden at a regional scale. Two areas studied as possible candidates for a radioactive waste repository were selected. The SGU well data and the hydraulic conductivity data evaluated from packer tests in boreholes at the sites were characterized statistically also considering possible spatial dependence. The two types of data were compared and the correlation between the data sets was investigated. This part of the study considered the uppermost 100 m of the packer test data, which is the approximate depth range covered by the SGU data. In a second part of the work the packer test data from the two study areas were analyzed in terms of possible depth trends. The exploratory statistical analyses suggested that the SGU data are useful for estimations of hydrogeological parameters for areas of different geologic settings. The geostatistical analysis provided further understanding of the spatial behaviour of the studied parameters. The analysis of depth dependence indicates that at both sites there is a layer of higher hydraulic conductivity close to the surface. Within these layers, about 200 and 280 m thick, resp., the conductivity decreases with increasing depth. At larger depths however, the decrease with depth is very slow or negligible. It was found that the scatter in the measured hydraulic conductivity data is very large compared to differences between the depth functions tested 33 refs, 21 figs, 6 tabs

  3. Benchmark of SIMULATE5 thermal hydraulics against the Frigg and NUPEC full bundle test experiments

    Energy Technology Data Exchange (ETDEWEB)

    Grandi, G. [Studsvik Scandpower, Inc., Idaho Falls, Idaho (United States); Lindahl, S.-O. [Studsvik Scandpower AB, Vasteras (Sweden)

    2011-07-01

    SIMULATE5 is Studsvik Scandpower's next generation nodal code. The core portion of the thermal hydraulic models of PWR and BWRs are treated as essentially identical, with each assembly having an active channel and a number of parallel water channels. In addition, the BWR assembly may be divided into four radial sub-assemblies. For natural circulation reactors, the BWR thermal hydraulic model is capable of modeling an entire vessel loop: core, chimney, upper plenum, standpipes, steam separators, downcomer, recirculation pumps, and lower plenum. This paper presents results of the validation of the BWR thermal hydraulic model against: (1) pressure drop data measured in the Frigg and NUPEC test facilities; (2) void fraction distribution measured in the Frigg and NUPEC loops; (3) quarter-assembly void fraction measured in the NUPEC experiments and (4) natural and forced circulation flow measurements in the Frigg loop. (author)

  4. Leak rate and burst test data for McGuire Unit 1 steam generator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Sherburne, P.A. [B& W Nuclear Service Co., Lynchburg, VA (United States); Frye, C.R. [Babcock & Wilcox Co., Lynchburg, VA (United States); Mayes, D.B. [Duke Power Co., Charlotte, NC (United States)

    1992-12-31

    To support the development of tube plugging criteria that would allow tubes with through-wall cracks to remain in service, sections of 12 tubes were removed from the McGuire Unit-1 steam generators. These tubes were sent to B&W Nuclear Service Company for metallographic examination and for determination of burst pressure and leak rate at both operating and faulted conditions. Primary water stress corrosion cracking (PWSCC) had degraded these tubes in the tube-to-tubesheet roll transitions. To measure primary-to-secondary leakage at pressures and temperatures equivalent to those in the McGuire Unit-1 steam generators, an autoclave-based test loop was designed and installed at the Babcock & Wilcox Lynchburg Research Center. Sections of the tube containing the roll transitions were then installed in the autoclave and actual primary- to-secondary leakage was measured at 288{degrees}C (550{degrees}F) and at 9 and 18.3 MPa (1300 and 2650 psi) pressure differentials. Following the leak test, the tubes were pressurized internally until the tube wall ruptured. Leak rate, burst pressure, and eddy-current information were then correlated with the through-wall crack lengths as determined by metallographic examination. Results confirm the ability to measure the crack length with eddy-current techniques. Results also support analytical and empirical models developed by the nuclear industry in calculating critical crack lengths in roll transitions.

  5. Measurement of residual CO2 saturation at a geological storage site using hydraulic tests

    Science.gov (United States)

    Rötting, T. S.; Martinez-Landa, L.; Carrera, J.; Russian, A.; Dentz, M.; Cubillo, B.

    2012-12-01

    Estimating long term capillary trapping of CO2 in aquifers remains a key challenge for CO2 storage. Zhang et al. (2011) proposed a combination of thermal, tracer, and hydraulic experiments to estimate the amount of CO2 trapped in the formation after a CO2 push and pull test. Of these three types of experiments, hydraulic tests are the simplest to perform and possibly the most informative. However, their potential has not yet been fully exploited. Here, a methodology is presented to interpret these tests and analyze which parameters can be estimated. Numerical and analytical solutions are used to simulate a continuous injection in a porous medium where residual CO2 has caused a reduction in hydraulic conductivity and an increase in storativity over a finite thickness (a few meters) skin around the injection well. The model results are interpreted using conventional pressure build-up and diagnostic plots (a plot of the drawdown s and the logarithmic derivative d s / d ln t of the drawdown as a function of time). The methodology is applied using the hydraulic parameters estimated for the Hontomin site (Northern Spain) where a Technology Demonstration Plant (TDP) for geological CO2 storage is planned to be set up. The reduction of hydraulic conductivity causes an increase in observed drawdowns, the increased storativity in the CO2 zone causes a delay in the drawdown curve with respect to the reference curve measured before CO2 injection. The duration (characteristic time) of these effects can be used to estimate the radius of the CO2 zone. The effects of reduced permeability and increased storativity are well separated from wellbore storage and natural formation responses, even if the CO2-brine interface is inclined (i.e. the CO2 forms a cone around the well). We find that both skin hydraulic conductivity and storativity (and thus residual CO2 saturation) can be obtained from the water injection test provided that water flow rate is carefully controlled and head build

  6. Safety and licensing issues that are being addressed by the Power Burst Facility test programs. [PWR; BWR

    Energy Technology Data Exchange (ETDEWEB)

    McCardell, R.K.; MacDonald, P.E.

    1980-01-01

    This paper presents an overview of the results of the experimental program being conducted in the Power Burst Facility and the relationship of these results to certain safety and licensing issues. The safety issues that were addressed by the Power-Cooling-Mismatch, Reactivity Initiated Accident, and Loss of Coolant Accident tests, which comprised the original test program in the Power Burst Facility, are discussed. The resolution of these safety issues based on the results of the thirty-six tests performed to date, is presented. The future resolution of safety issues identified in the new Power Burst Facility test program which consists of tests which simulate BWR and PWR operational transients, anticipated transients without scram, and severe fuel damage accidents, is described.

  7. Preliminary Multirod Burst Test Program results and implications of interest to reactor safety evaluations

    Energy Technology Data Exchange (ETDEWEB)

    Chapman, R.H. (comp.)

    1978-01-01

    The Multirod Burst Test (MRBT) Program, in progress at Oak Ridge National Laboratory, is investigating LWR cladding deformation in single- and multirod test arrays under conditions representative of reflood and refill phases of a LOCA. In these tests internally pressurized, unirradiated Zircaloy-4 tubes containing electrically heated fuel simulators are tested to failure in a low-pressure, superheated-steam environment. The tubes are ''uniformly'' heated over a 915-mm length; the simulator pressure, due to the small enclosed gas volume, also varies with temperature (and deformation) during the test. Two 4 x 4 multirod tests (B-1 and B-2), one with and one without the shroud being heated, have been conducted with a bundle heating rate of approx. 29/sup 0/C/sec; initial pressure conditions for these tests were selected to cause failure at about 860/sup 0/C. An additional 4 x 4 array (B-3) was tested using a bundle heating rate of approx. 10/sup 0/C/sec; the shroud was also heated in this test. Initial conditions were adjusted to cause failure at approx. 760/sup 0/C. Posttest examination (including flow tests) of the B-1 and B-2 test arrays, is essentially complete, and pertinent data are included in this summary.

  8. Thermal hydraulic studies in steam generator test facility

    Energy Technology Data Exchange (ETDEWEB)

    Vinod, V.; Suresh Kumar, V.A.; Noushad, I.B.; Ellappan, T.R.; Rajan, K.K.; Rajan, M.; Vaidyanathan, G. [Engineering Development Group Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India)

    2005-07-01

    Full text of publication follows: A 500 MWe fast breeder reactor is being constructed at Kalpakkam, India. This is a sodium cooled reactor with two primary and two secondary sodium loops with total 8 steam generators. The typical advantage of fast breeder plants is the high operating temperature of steam cycles and the high plant efficiency. To produce this high pressure and high temperature steam, once through straight tube vertical sodium heated steam generators are used. The steam is generated from the heat produced in the reactor core and being transported through primary and secondary sodium circuits. The steam generator is a 25 m high middle supported steam generator with expansion bend and 23 m heat transfer length. Steam Generator Test Facility (SGTF) constructed at Indira Gandhi Centre for Atomic Research (IGCAR), Kalpakkam aims at performing various tests on a 5.5 MWt steam generator. This vertically simulated test article is similar in all respects to the proposed 157 MWt steam generator module for the Prototype Fast Breeder Reactor (PFBR), with reduced number of tubes. Heat transfer performance tests are done with this 19 tube steam generator at various load conditions. Sodium circuit for the SGTF is equipped with oil fired heater as heat source and centrifugal sodium pump, to pump sodium at 105 m{sup 3}/hr flow rate. Other typical components like sodium to air heat exchanger, sodium purification system and hydrogen leak detection system is also present in the sodium circuit. High pressure steam produced in the steam generator is dumped in a condenser and recycled. Important tests planned in SGTF are the heat transfer performance test, stability test, endurance test and performance test of steam generator under various transients. The controlled operation of steam generator will be studied with possible control schemes. A steady state simulation of the steam generator is done with a mathematical model. This paper gives the details of heat transfer

  9. NUMERICAL MODELING OF MULTICYLINDER ELECTRO-HYDRAULIC SYSTEM AND CONTROLLER DESIGN FOR SHOCK TEST MACHINE

    Institute of Scientific and Technical Information of China (English)

    CHU Deying; ZHANG Zhiyi; WANG Gongxian; HUA Hongxing

    2007-01-01

    A high fidelity dynamic model of a high-energy hydraulically-actuated shock test machine for heavy weight devices is presented to satisfy the newly-built shock resistance standard and simulate the actual underwater explosion environments in laboratory as well as increase the testing capability of shock test machine. In order to produce the required negative shock pulse in the given time duration, four hydraulic actuators are utilized. The model is then used to formulate an advanced feedforward controller for the system to produce the required negative waveform and to address the motion synchronization of the four cylinders. The model provides a safe and easily controllable way to perform a "virtual testing" before starting potentially destructive tests on specimen and to predict performance of the system. Simulation results have demonstrated the effectiveness of the controller.

  10. Hydraulic testing of helium cooled irradiation rigs of the IFMIF High Flux Test Module

    Energy Technology Data Exchange (ETDEWEB)

    Klein, Christine, E-mail: Christine.Klein@kit.edu [Karlsruhe Institute of Technology, INR, Eggenstein-Leopoldshafen (Germany); Arbeiter, Frederik; Jackowski, Thomas; Martin, Thomas; Schlindwein, Georg [Karlsruhe Institute of Technology, INR, Eggenstein-Leopoldshafen (Germany)

    2012-08-15

    Highlights: Black-Right-Pointing-Pointer Uniform perfusion of the multiple parallel minichannels of the rig model B by helium gas, which is of importance to obtain uniform and predictable temperatures, could be verified by measuring the mean velocity profiles of the rectangular jets are measured using hot-wire anemometry. Black-Right-Pointing-Pointer The pressure drop in the test section with rig model B was measured and delivers data for the validation of computational fluid dynamics (CFD) modeling approach for application in the IFMIF High Flux Test Module. The pressure drop depends significantly on the pressure level; acceleration resulting from the volumetric expansion of helium gas has to be modeled carefully in simulations. Black-Right-Pointing-Pointer Measurements with strain gage show the pressure depending deformation of the compartment container without the rig. The results agree well with simulations and approximation calculations. - Abstract: The hydraulic testing of a single 1:1 irradiation rig inside a mock-up container is part of the validation activities which support the engineering design of the High Flux Test Module. Uniform perfusion of the multiple parallel minichannels of the irradiation rigs by helium gas is of importance to obtain uniform and predictable temperatures. To evaluate the uniform distribution to the different parallel minichannels, the mean velocity profiles of the rectangular jets are measured using hot-wire anemometry. The velocity profiles show a symmetric and constant distribution of the mass flow to the parallel minichannels. The pressure drop in the test section with one of the candidate rig shapes is measured. The pressure drop depends significantly on the entrance pressure level; acceleration resulting from the volumetric expansion of helium gas has to be taken into account in simulations. Measurements with strain gage show the pressure depending deformation of the compartment container without the rig. The results agree

  11. Joint inversion of hydraulic head and self-potential data associated with harmonic pumping tests

    Science.gov (United States)

    Soueid Ahmed, A.; Jardani, A.; Revil, A.; Dupont, J. P.

    2016-09-01

    Harmonic pumping tests consist in stimulating an aquifer by the means of hydraulic stimulations at some discrete frequencies. The inverse problem consisting in retrieving the hydraulic properties is inherently ill posed and is usually underdetermined when considering the number of well head data available in field conditions. To better constrain this inverse problem, we add self-potential data recorded at the ground surface to the head data. The self-potential method is a passive geophysical method. Its signals are generated by the groundwater flow through an electrokinetic coupling. We showed using a 3-D saturated unconfined synthetic aquifer that the self-potential method significantly improves the results of the harmonic hydraulic tomography. The hydroelectric forward problem is obtained by solving first the Richards equation, describing the groundwater flow, and then using the result in an electrical Poisson equation describing the self-potential problem. The joint inversion problem is solved using a reduction model based on the principal component geostatistical approach. In this method, the large prior covariance matrix is truncated and replaced by its low-rank approximation, allowing thus for notable computational time and storage savings. Three test cases are studied, to assess the validity of our approach. In the first test, we show that when the number of harmonic stimulations is low, combining the harmonic hydraulic and self-potential data does not improve the inversion results. In the second test where enough harmonic stimulations are performed, a significant improvement of the hydraulic parameters is observed. In the last synthetic test, we show that the electrical conductivity field required to invert the self-potential data can be determined with enough accuracy using an electrical resistivity tomography survey using the same electrodes configuration as used for the self-potential investigation.

  12. Test Rig Design and Presentation for a Hydraulic Yaw System

    DEFF Research Database (Denmark)

    Stubkier, Søren; Pedersen, Henrik C.; Andersen, Torben Ole

    2013-01-01

    dynamics under real conditions. The behavior of the system is analyzed with regard to 20 years of operation. This is for example done by applying loads from different design load cases, e.g. normal turbulence, extreme turbulence and different fault scenarios on the turbine. The paper first presents...... an introduction with the current state of the art and problem description, followed by a system description, where the system is designed and dimensioned. Based on the design, results from the test rig are presented and analyzed. Finally a conclusion summing up the design, model and test results is given....

  13. Hydraulic laboratory testing of Sontek-IQ Plus

    Science.gov (United States)

    Fulford, Janice M.; Kimball, Scott

    2015-11-10

    The SonTek-IQ Plus (IQ Plus) is a bottom-mounted Doppler instrument used for the measurement of water depth and velocity. Evaluation testing of the IQ Plus was performed to assess the accuracy of water depth, discharge, and velocity measurements. The IQ Plus met the manufacturer’s specifications and the U.S. Geological Survey (USGS) standard for depth accuracy measurement when the unit was installed, according to the manufacturer’s instructions, at 0 degrees pitch and roll. However, because of the limited depth testing conducted, the depth measurement is not recommended as a primary stage measurement. The IQ Plus was tested in a large indoor tilting flume in a 5-foot (ft) wide, approximately 2.3-ft deep section with mean velocities of 0.5, 1, 2, and 3 ft per second. Four IQ Plus instruments using firmware 1.52 tested for water-discharge accuracy using SonTek’s “theoretical” discharge method had a negative bias of -2.4 to -11.6 percent when compared with discharge measured with a SonTek FlowTracker and the midsection discharge method. The IQ Pluses with firmware 1.52 did not meet the manufacturer’s specification of +/-1 percent for measuring velocity. Three IQ Pluses using firmware 1.60 and SonTek’s “theoretical” method had a difference of -1.6 to -7.9 percent when compared with discharge measured with a SonTek FlowTracker and the midsection method. Mean-velocity measurements with firmware 1.60 met the manufacturer’s specification and Price Type AA meter accuracy requirements when compared with FlowTracker measurements. Because of the instrument’s velocity accuracy, the SonTek-IQ Plus with firmware 1.60 is considered acceptable for use as an index velocity instrument for the USGS. The discharge computed by the SonTek-IQ Plus during the tests had a substantial negative bias and will not be as accurate as a discharge computed with the index velocity method. The USGS does not recommend the use of undocumented computation methods, such as Son

  14. CFX Analysis of the CANDU Moderator Thermal-Hydraulics in the Stern Lab. Test Facility

    Science.gov (United States)

    Kim, Hyoung Tae

    2014-06-01

    A numerical calculation with the commercial CFD code CFX is conducted for a test facility simulating the CANDU moderator thermal-hydraulics. Two kinds of moderator thermal-hydraulic tests at Stern Laboratories Inc. were performed in the full geometric configuration of the CANDU moderator circulating vessel, which is called a Calandria, housing a matrix of horizontal rod bundles simulating the Calandria tubes. The first of these tests is the pressure drop measurement of a cross flow in the horizontal rod bundles. The other is the local temperature measurement on the cross section of the horizontal cylinder vessel simulating the Calandria. In the present study the full geometric details of the Calandria are incorporated in the grid generation of the computational domain to which the boundary conditions for each experiment are applied. The numerical solutions are reviewed and compared with the available test data.

  15. Characterizing hydraulic fractures in shale gas reservoirs using transient pressure tests

    Directory of Open Access Journals (Sweden)

    Cong Wang

    2015-06-01

    This work presents an unconventional gas reservoir simulator and its application to quantify hydraulic fractures in shale gas reservoirs using transient pressure data. The numerical model incorporates most known physical processes for gas production from unconventional reservoirs, including two-phase flow of liquid and gas, Klinkenberg effect, non-Darcy flow, and nonlinear adsorption. In addition, the model is able to handle various types and scales of fractures or heterogeneity using continuum, discrete or hybrid modeling approaches under different well production conditions of varying rate or pressure. Our modeling studies indicate that the most sensitive parameter of hydraulic fractures to early transient gas flow through extremely low permeability rock is actually the fracture-matrix contacting area, generated by fracturing stimulation. Based on this observation, it is possible to use transient pressure testing data to estimate the area of fractures generated from fracturing operations. We will conduct a series of modeling studies and present a methodology using typical transient pressure responses, simulated by the numerical model, to estimate fracture areas created or to quantity hydraulic fractures with traditional well testing technology. The type curves of pressure transients from this study can be used to quantify hydraulic fractures in field application.

  16. Joint Estimation of Hydraulic and Poroelastic Parameters from a Pumping Test.

    Science.gov (United States)

    Berg, Steven J; Illman, Walter A; Mok, Chin Man W

    2015-01-01

    The coupling of hydraulic and poroelastic processes is critical in predicting processes involving the deformation of the geologic medium in response to fluid extraction or injection. Numerical models that consider the coupling of hydraulic and poroelastic processes require the knowledge of relevant parameters for both aquifer and aquitard units. In this study, we jointly estimated hydraulic and poroelastic parameters from pumping test data exhibiting "reverse water level fluctuations," known as the Noordbergum effect, in aquitards adjacent to a pumped aquifer. The joint estimation was performed by coupling BIOT2, a finite element, two-dimensional, axisymmetric, groundwater model that considers poroelastic effects with the parameter estimation code PEST. We first tested our approach using a synthetic data set with known parameters. Results of the synthetic case showed that for a simple layered system, it was possible to reproduce accurately both the hydraulic and poroelastic properties for each layer. We next applied the approach to pumping test data collected at the North Campus Research Site (NCRS) on the University of Waterloo (UW) campus. Based on the detailed knowledge of stratigraphy, a five-layer system was modeled. Parameter estimation was performed by: (1) matching drawdown data individually from each observation port and (2) matching drawdown data from all ports at a single well simultaneously. The estimated hydraulic parameters were compared to those obtained by other means at the site yielding good agreement. However, the estimated shear modulus was higher than the static shear modulus, but was within the range of dynamic shear modulus reported in the literature, potentially suggesting a loading rate effect.

  17. Data report of BWR post-CHF tests. Transient core thermal-hydraulic test program. Contract research

    Energy Technology Data Exchange (ETDEWEB)

    Iguchi, Tadashi; Itoh, Hideo; Kiuchi, Toshio; Watanabe, Hironori; Kimura, Mamoru; Anoda, Yoshinari [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2001-03-01

    JAERI has been performing transient core thermal-hydraulic test program. In the program, authors performed BWR/ABWR DBE simulation tests with a test facility, which can simulate BWR/ABWR transients. The test facility has a 4 x 4 bundle core simulator with 15-rod heaters and one non-heated rod. Through the tests, authors quantified the thermal safety margin for core cooling. In order to quantify the thermal safety margin, authors collected experimental data on post-CHF. The data are essential for the evaluation of clad temperature transient when core heat-up occurs during DBEs. In comparison with previous post-CHF tests, present experiments were performed in much wider experimental condition, covering high clad temperature, low to high pressure and low to high mass flux. Further, data at wider elevation (lower to higher elevation of core) were obtained in the present experiments, which make possible to discuss the effect of axial position on thermal-hydraulics, while previous works usually discuss the thermal-hydraulics at the position where the first heat-up occurs. This data report describes test procedure, test condition and major experimental data of post-CHF tests. (author)

  18. Thermal hydraulic similarity analysis of the integral effect test facility for main steam line break events

    Energy Technology Data Exchange (ETDEWEB)

    Choi, K.Y.; Park, H.S.; Euh, D.J.; Kwon, T.S.; Baek, W.P. [Thermal Hydraulic Safety Research Division Korea Atomic Energy Research Institute 150 Dukjin-Dong, Yusong-Gu, Daejeon 305-353 (Korea, Republic of)

    2005-07-01

    Full text of publication follows: A thermal-hydraulic integral effect test facility, ATLAS (Advanced Thermal-hydraulic Test Loop for Accident Simulation), is being constructed at Korea Atomic Energy Research Institute (KAERI). The ATLAS is a 1/2 reduced height and 1/288 volume scaled test facility based on the design features of the APR1400, an evolutionary pressurized water reactor developed by Korean industry. The ATLAS will be used to get more realistic understanding of the thermal hydraulic phenomena following postulated events and to carry out performance evaluation and safety analysis of the reference plants. The MSLB (Main Steam Line Break) event is one of the representative non-LOCA events and thermalhydraulic phenomena following the event are to be investigated in the ATLAS. In this paper, thermal hydraulic similarity for MSLB events between the ATLAS and the prototype plant, APR1400 is assessed by using the MARS code, which is a multi-dimensional best-estimate thermal hydraulic code being developed by KAERI. Several cases including SLBFPLOOP and SLBFP are taken into account for similarity analysis in this paper. The neutronic effects such as moderator temperature coefficients and doppler reactivity in APR1400 are not considered in this study. The same control logics for the major sequence of events such as reactor trip, turbine trip, valve opening and actuation of the emergency cooling system are applied to the ATLAS and the APR1400. The present investigation is focused on the scaling and the reduced power effects on thermal hydraulic similarity after initiation of MSLB events. It is found that the ATLAS facility has the similar thermal hydraulic responses against the MSLB events. However, the initial high secondary pressure before the MSLB initiation resulted in different primary pressure and temperature progression from the APR1400. The break flow from the main steam line is found to be one of the most dominating parameters governing the transient

  19. In-situ tube burst testing and high-temperature deformation behavior of candidate materials for accident tolerant fuel cladding

    Science.gov (United States)

    Gussev, M. N.; Byun, T. S.; Yamamoto, Y.; Maloy, S. A.; Terrani, K. A.

    2015-11-01

    One of the most essential properties of accident tolerant fuel (ATF) for maintaining structural integrity during a loss-of-coolant accident (LOCA) is high resistance of the cladding to plastic deformation and burst failure, since the deformation and burst behavior governs the cooling efficiency of flow channels and the process of fission product release. To simulate and evaluate the deformation and burst process of thin-walled cladding, an in-situ testing and evaluation method has been developed on the basis of visual imaging and image analysis techniques. The method uses a specialized optics system consisting of a high-resolution video camera, a light filtering unit, and monochromatic light sources. The in-situ testing is performed using a 50 mm long pressurized thin-walled tubular specimen set in a programmable furnace. As the first application, ten (10) candidate cladding materials for ATF, i.e., five FeCrAl alloys and five nanostructured steels, were tested using the newly developed method, and the time-dependent images were analyzed to produce detailed deformation and burst data such as true hoop stress, strain (creep) rate, and failure stress. Relatively soft FeCrAl alloys deformed and burst below 800 °C, while negligible strain rates were measured for higher strength alloys.

  20. Toward A 3-D Picture of Hydraulic Conductivity With Multilevel Slug Tests

    Science.gov (United States)

    McElwee, C. D.; McElwee, C. D.; Ross, H. C.

    2001-12-01

    The GEMS (Geohydrologic Experiment and Monitoring Site) field area has been established (in the Kansas River valley near Lawrence, Kansas) for a variety of reasons relating to research and teaching in hydrogeology at the University of Kansas. Over 70 wells have been installed for various purposes. The site overlies an alluvial aquifer with a total thickness of about 70 feet. The water table is typically about 20 feet below the surface, giving a total saturated thickness of about 50 feet. The upper part of the aquifer is finer material consisting of silt and clay. Typically, the lower 35 feet of the aquifer is sand and gravel. A number of wells through out the site are fully screened through the sand and gravel aquifer. Some of these fully screened wells are larger diameters; however, most wells are constructed of 2 inch PVC casing. Slug tests are widely used in hydrogeology to measure hydraulic conductivity. Over the last several years we have been conducting research to improve the slug test method. We have previously reported the detailed structure of hydraulic conductivity that can be seen in a 5 inch well (McElwee and Zemansky, EOS, v. 80, no. 46, p. F397, 1999) at this site, using multilevel slug tests. The existing 2 inch, fully screened wells are spread out over the site and offer the opportunity for developing a 3-D picture of the hydraulic conductivity distribution. However, it is difficult to develop a system that allows multilevel slug tests to be done accurately and efficiently in a 2 inch well. This is especially true in regions of very high hydraulic conductivity, where the water velocity in the casing will be relatively high. The resistance caused by frictional forces in the equipment must be minimized and a model taking account of these forces must be used. We have developed a system (equipment, software, and technique) for performing multilevel slug tests in 2 inch wells. Some equipment configurations work better than others. The data that we have

  1. Burst testing of condoms. I. Basic features of the force-deformation curve of latex-rubber condoms.

    Science.gov (United States)

    Wilson, T W; Andrady, A L

    1992-01-01

    Inflation of a rubber condom involves biaxial deformation of the material which can be modeled by the use of an appropriate strain-energy function. Force versus deformation data for uniaxial extension of strips of condoms were used to determine the parameters for Ogden's form of a strain-energy function. These parameters were then used to fit experimentally obtained burst test data to a stress-strain equation formulated for inflation of condoms in a burst test. Experimental data on inflation of condoms agree well with theoretical curves verifying the applicability of the biaxial stress-strain equation to the particular strain-energy function on which it is based.

  2. Avoidance of harvesting and sampling artefacts in hydraulic analyses: a protocol tested on Malus domestica.

    Science.gov (United States)

    Beikircher, Barbara; Mayr, Stefan

    2016-06-01

    A prerequisite for reliable hydraulic measurements is an accurate collection of the plant material. Thereby, the native hydraulic state of the sample has to be preserved during harvesting (i.e., cutting the plant or plant parts) and preparation (i.e., excising the target section). This is particularly difficult when harvesting has to be done under transpiring conditions. In this article, we present a harvesting and sampling protocol designed for hydraulic measurements on Malus domestica Borkh. and checked for possible sampling artefacts. To test for artefacts, we analysed the percentage loss of hydraulic conductivity, maximum specific conductivity and water contents of bark and wood of branches, taking into account conduit length, time of day of harvesting, different shoot ages and seasonal effects. Our results prove that use of appropriate protocols can avoid artefactual embolization or refilling even when the xylem is under tension at harvest. The presented protocol was developed for Malus but may also be applied for other angiosperms with similar anatomy and refilling characteristics.

  3. Estimating Hydraulic Conductivities in a Fractured Shale Formation from Pressure Pulse Testing and 3d Modeling

    Science.gov (United States)

    Courbet, C.; DICK, P.; Lefevre, M.; Wittebroodt, C.; Matray, J.; Barnichon, J.

    2013-12-01

    In the framework of its research on the deep disposal of radioactive waste in shale formations, the French Institute for Radiological Protection and Nuclear Safety (IRSN) has developed a large array of in situ programs concerning the confining properties of shales in their underground research laboratory at Tournemire (SW France). One of its aims is to evaluate the occurrence and processes controlling radionuclide migration through the host rock, from the disposal system to the biosphere. Past research programs carried out at Tournemire covered mechanical, hydro-mechanical and physico-chemical properties of the Tournemire shale as well as water chemistry and long-term behaviour of the host rock. Studies show that fluid circulations in the undisturbed matrix are very slow (hydraulic conductivity of 10-14 to 10-15 m.s-1). However, recent work related to the occurrence of small scale fractures and clay-rich fault gouges indicate that fluid circulations may have been significantly modified in the vicinity of such features. To assess the transport properties associated with such faults, IRSN designed a series of in situ and laboratory experiments to evaluate the contribution of both diffusive and advective process on water and solute flux through a clay-rich fault zone (fault core and damaged zone) and in an undisturbed shale formation. As part of these studies, Modular Mini-Packer System (MMPS) hydraulic testing was conducted in multiple boreholes to characterize hydraulic conductivities within the formation. Pressure data collected during the hydraulic tests were analyzed using the nSIGHTS (n-dimensional Statistical Inverse Graphical Hydraulic Test Simulator) code to estimate hydraulic conductivity and formation pressures of the tested intervals. Preliminary results indicate hydraulic conductivities of 5.10-12 m.s-1 in the fault core and damaged zone and 10-14 m.s-1 in the adjacent undisturbed shale. Furthermore, when compared with neutron porosity data from borehole

  4. Study on test and preparation of load spectrum of hydraulic excavator

    Science.gov (United States)

    Zhang, Hong; Feng, Guodi; Zhang, Haijun; Wang, Xiaofeng; Zhang, Yingzhi

    2017-01-01

    Due to harsh working conditions, the components of hydraulic excavator are subject to large amount of alternating load and random load during the operation and they are seriously damaged. The test of load signal and preparation of load spectrum for the hydraulic excavator are studied in this paper. In the first place, pretreatment of filtering and noise reduction for load signal is conducted based on experimental test on site and experimental working condition analysis. After the load signal is processed in sections, distribution fitting is performed for information like mean amplitude after rain flow counting with the approach of probability statistics to get the probability distribution function for mean value and amplitude value. Finally the two dimensional load spectrum for mean amplitude is obtained and program spectrum loading solution of fatigue experiment is given. The study of load signal test and load spectrum preparation method for hydraulic excavator conducted in this paper is of great significance for clarification of load distribution of excavator and further reliability test of excavator.

  5. Pinhole test for identifying susceptibility of soils to piping erosion: effect water quality and hydraulic head

    Energy Technology Data Exchange (ETDEWEB)

    Nadal Romero, E.; Verachtert, E.; Poesen, J.

    2009-07-01

    Piping has been observed in both natural and soils, as well as under different types of land uses and vegetation covers. Despite its importance, no standard widely-applied methodology exists to assess susceptibility of soils to piping. This study aims at evaluating the pinhole test for assessing the susceptibility of soils to piping under different conditions. More precisely, the effects of hydraulic head and water quality are being assessed. Topsoil samples (remoulded specimens) with a small range of water contents were taken in Central Belgium (Heverlee) and the susceptibility of these soil samples are investigated under standardized laboratory conditions with a pinhole test device. Three hydraulic heads (50,180 and 380 mm) and two water qualities (tap and distilled water) were used, reflecting dominant field conditions. (Author) 6 refs.

  6. Hydraulic Testing of Salado Formation Evaporites at the Waste Isolation Pilot Plant Site: Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Beauheim, Richard L.; Domski, Paul S.; Roberts, Randall M.

    1999-07-01

    This report presents interpretations of hydraulic tests conducted in bedded evaporates of the Salado Formation from May 1992 through May 1995 at the Waste Isolation Pilot Plant (WIPP) site in southeastern New Mexico. The WIPP is a US Department of Energy research and development facility designed to demonstrate safe disposal of transuranic wastes from the nation's defense programs. The WIPP disposal horizon is located in the lower portion of the Permian Salado Formation. The hydraulic tests discussed in this report were performed in the WIPP underground facility by INTERA inc. (now Duke Engineering and Services, Inc.), Austin, Texas, following the Field Operations Plan and Addendum prepared by Saulnier (1988, 1991 ) under the technical direction of Sandia National Laboratories, Albuquerque, New Mexico.

  7. Analysis of Responses From Hydraulic Testing of the Lower Carbonate Aquifer at Yucca Flat, Nevada Test Site, Nye County, Nevada

    Science.gov (United States)

    Bhark, E. W.; Ruskauff, G.

    2005-12-01

    The Yucca Flat corrective action unit extends over an approximately 120 square-mile basin at the Nevada Test Site (NTS), southern Nevada, and was the site for over 650 historical underground nuclear tests. The lower carbonate aquifer (LCA), roughly 1,800 feet below ground surface at Yucca Flat and with a confined thickness of several thousand feet, is the primary aquifer for much of southern Nevada and underlies the full extent of Yucca Flat. Within the last decade, long-term (multiple-day) single- and multiple-well hydraulic tests have been performed to better define aquifer properties over larger scales. The LCA is highly heterogeneous, both laterally and vertically across Yucca Flat, reflecting differences in fracturing and fault density. As such, analysis of the recent testing data requires the consideration of heterogeneous hydraulic properties at multiple spatial scales. Three individual hydraulic tests are presented that portray the marked spatial variability of hydraulic properties related to both local fracturing and basin-scale faulting across Yucca Flat. Two ten-day single-well tests (wells ER-7-1, ER-6-2) and one ninety-day multiple-well test (well cluster ER-6-1) are considered. Interpretive and numerical analyses are based upon the log-log diagnostic plots of drawdown and recovery from pumping, utilizing both the head change and derivative. Heterogeneity is considered using the flow dimension, which represents a variable formation area of flow away from the well, and proves to be a fundamental analytical tool. All hydraulic parameter estimates, including flow dimension, are complete with a measure of uncertainty. The composite interpretation of all data results in a conceptual flow model representative of two spatially continuous scales. At the larger basin (km) scale, the data indicate a fracture- or high permeability strip-dominated flow regime created by fault-related features. Ubiquitous north-south trending faults throughout Yucca Flat appear to

  8. Final Report - Hydraulic Conductivity with Depth for Underground Test Area (UGTA) Wells

    Energy Technology Data Exchange (ETDEWEB)

    P. Oberlander; D. McGraw; C. Russell

    2007-10-31

    Hydraulic conductivity with depth has been calculated for Underground Test Area (UGTA) wells in volcanic tuff and carbonate rock. The following wells in volcanic tuff are evaluated: ER-EC-1, ER-EC-2a, ER-EC-4, ER-EC-5, ER-5-4#2, ER-EC-6, ER-EC-7, and ER-EC-8. The following wells in carbonate rock are evaluated: ER-7-1, ER-6-1, ER-6-1#2, and ER-12-3. There are a sufficient number of wells in volcanic tuff and carbonate rock to associate the conductivity values with the specific hydrogeologic characteristics such as the stratigraphic unit, hydrostratigraphic unit, hydrogeologic unit, lithologic modifier, and alteration modifier used to describe the hydrogeologic setting. Associating hydraulic conductivity with hydrogeologic characteristics allows an evaluation of the data range and the statistical distribution of values. These results are relevant to how these units are considered in conceptual models and represented in groundwater models. The wells in volcanic tuff illustrate a wide range of data values and data distributions when associated with specific hydrogeologic characteristics. Hydraulic conductivity data within a hydrogeologic characteristic can display normal distributions, lognormal distributions, semi-uniform distribution, or no identifiable distribution. There can be multiple types of distributions within a hydrogeologic characteristic such as a single stratigraphic unit. This finding has implications for assigning summary hydrogeologic characteristics to hydrostratigraphic and hydrogeologic units. The results presented herein are specific to the hydrogeologic characteristic and to the wells used to describe hydraulic conductivity. The wells in carbonate rock are associated with a fewer number of hydrogeologic characteristics. That is, UGTA wells constructed in carbonate rock have tended to be in similar hydrogeologic materials, and show a wide range in hydraulic conductivity values and data distributions. Associations of hydraulic conductivity and

  9. Out-of-pile Verifying Test for the Hydraulic Stability of the CARR Standard Fuel Assembly

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The CARR standard fuel element is a flat-plate-type assembly. A fuel plate consists of 0.6 mmthickness layer of uranium- silicon - aluminum fuel (U3Si2-Al) and 0.38 mm thickness of aluminumcladding. The fuel plates are attached to aluminum alloy side plates by a "roll swaging" technique. Thistype of fuel assembly is first used in China. The testing simulates the in-pile thermal-hydraulic operating conditions except for neutron

  10. Neutron Tomography Using Mobile Neutron Generators for Assessment of Void Distributions in Thermal Hydraulic Test Loops

    OpenAIRE

    Andersson, Peter; Bjelkenstedt, Tom; Andersson Sundén, Erik; Sjöstrand, Henrik; Jacobsson, Staffan

    2015-01-01

    Detailed knowledge of the lateral distribution of steam (void) and water in a nuclear fuel assembly is of great value for nuclear reactor operators and fuel manufacturers, with consequences for both reactor safety and economy of operation. Therefore, nuclear relevant two-phase flows are being studied at dedicated thermal-hydraulic test loop, using twophase flow systems ranging from simplified geometries such as heated circular pipes to full scale mock-ups of nuclear fuel assemblies. Neutron t...

  11. Structural-hydraulic test of the liquid metal EURISOL target mock-up

    Science.gov (United States)

    Milenković, Rade Ž.; Dementjevs, Sergejs; Samec, Karel; Platacis, Ernests; Zik, Anatolij; Flerov, Aleksej; Manfrin, Enzo; Thomsen, Knud

    2009-08-01

    Structural-hydraulic tests of the European Isotope Separation On-Line (EURISOL) neutron converter target mock-up, named MErcury Target EXperiment 1 (METEX 1), have been conducted by Paul Scherrer Institut (PSI, Switzerland) in cooperation with Institute of Physics of the University of Latvia (IPUL, Latvia). PSI proceeded with extensive thermal-hydraulic and structural computational studies, followed by the target mock-up tests carried out on the mercury loop at IPUL. One of the main goals of the METEX 1 test is to investigate the hydraulic and structural behaviour of the EURISOL target mock-up for various inlet flow conditions (i.e. mass flow rates) and, in particular, for nominal operating flow rate and pressure in the system. The experimental results were analysed by advanced time-frequency methods such as Short-Time Fourier Transform in order to check the vibration characteristics of the mock-up and the resonance risk. The experimental results (obtained in METEX 1), which include inlet flow rate, pressure of the cover gas, total pressure loss, structural acceleration, sound and strain data, were jointly analysed together with numerical data obtained from Computational Fluid Dynamics (CFD).

  12. Lead Coolant Test Facility Systems Design, Thermal Hydraulic Analysis and Cost Estimate

    Energy Technology Data Exchange (ETDEWEB)

    Soli Khericha; Edwin Harvego; John Svoboda; Ryan Dalling

    2012-01-01

    The Idaho National Laboratory prepared a preliminary technical and functional requirements (T&FR), thermal hydraulic design and cost estimate for a lead coolant test facility. The purpose of this small scale facility is to simulate lead coolant fast reactor (LFR) coolant flow in an open lattice geometry core using seven electrical rods and liquid lead or lead-bismuth eutectic coolant. Based on review of current world lead or lead-bismuth test facilities and research needs listed in the Generation IV Roadmap, five broad areas of requirements were identified as listed: (1) Develop and Demonstrate Feasibility of Submerged Heat Exchanger; (2) Develop and Demonstrate Open-lattice Flow in Electrically Heated Core; (3) Develop and Demonstrate Chemistry Control; (4) Demonstrate Safe Operation; and (5) Provision for Future Testing. This paper discusses the preliminary design of systems, thermal hydraulic analysis, and simplified cost estimate. The facility thermal hydraulic design is based on the maximum simulated core power using seven electrical heater rods of 420 kW; average linear heat generation rate of 300 W/cm. The core inlet temperature for liquid lead or Pb/Bi eutectic is 4200 C. The design includes approximately seventy-five data measurements such as pressure, temperature, and flow rates. The preliminary estimated cost of construction of the facility is $3.7M (in 2006 $). It is also estimated that the facility will require two years to be constructed and ready for operation.

  13. Development of scaling laws on thermal-hydraulic effect test facility for CANDU-6 moderator

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. Y.; Jung, Y. S.; Kim, N. S. [Handong University, Pohang (Korea, Republic of); Kim, M. W.; Kim, H. J. [Korea Institute of Nuclear Safety, Taejon (Korea, Republic of)

    2004-07-01

    The scaling laws on thermal-hydraulic effect test facility for CANDU-6 moderator (HGU-KINS) have been investigated and manufactured. The basic laws are the satisfaction of energy conservation and dimensionless number, Ar and Re, for the similarities of thermal-hydraulic properties. And then the thermal-hydraulic scaling analyses of test facilities, SPEL(1/10 scale) and STERN(1/4 scale), have been identified by the present method. As a result, in the case of SPEL, the energy conservation is confirmed, but the similarities of Ar and the heat density are not considered. In the case of STERN, the energy conservation and the characteristics of Ar were well defined. But the similarity of the heat density is unsatisfied, either. Therefore the present method was applied with 1/8 length scale. For the performance test, CFD analysis has been accomplished by CFX5. The results of flow pattern certifications and variation of axial properties with CANDU show that the present scaling method is acceptable.

  14. Lead coolant test facility systems design, thermal hydraulic analysis and cost estimate

    Energy Technology Data Exchange (ETDEWEB)

    Khericha, Soli, E-mail: slk2@inel.gov [Battelle Energy Alliance, LLC, Idaho National Laboratory, Idaho Falls, ID 83415 (United States); Harvego, Edwin; Svoboda, John; Evans, Robert [Battelle Energy Alliance, LLC, Idaho National Laboratory, Idaho Falls, ID 83415 (United States); Dalling, Ryan [ExxonMobil Gas and Power Marketing, Houston, TX 77069 (United States)

    2012-01-15

    The Idaho National Laboratory prepared a preliminary technical and functional requirements (T and FR), thermal hydraulic design and cost estimate for a lead coolant test facility. The purpose of this small scale facility is to simulate lead coolant fast reactor (LFR) coolant flow in an open lattice geometry core using seven electrical rods and liquid lead or lead-bismuth eutectic coolant. Based on review of current world lead or lead-bismuth test facilities and research needs listed in the Generation IV Roadmap, five broad areas of requirements were identified as listed below: Bullet Develop and demonstrate feasibility of submerged heat exchanger. Bullet Develop and demonstrate open-lattice flow in electrically heated core. Bullet Develop and demonstrate chemistry control. Bullet Demonstrate safe operation. Bullet Provision for future testing. This paper discusses the preliminary design of systems, thermal hydraulic analysis, and simplified cost estimated. The facility thermal hydraulic design is based on the maximum simulated core power using seven electrical heater rods of 420 kW; average linear heat generation rate of 300 W/cm. The core inlet temperature for liquid lead or Pb/Bi eutectic is 4200 Degree-Sign C. The design includes approximately seventy-five data measurements such as pressure, temperature, and flow rates. The preliminary estimated cost of construction of the facility is $3.7M (in 2006 $). It is also estimated that the facility will require two years to be constructed and ready for operation.

  15. Testing the anisotropy in the angular distribution of $Fermi$/GBM gamma-ray bursts

    CERN Document Server

    Tarnopolski, Mariusz

    2015-01-01

    Gamma-ray bursts (GRBs) were confirmed to be of extragalactic origin due to their isotropic angular distribution, combined with the fact that they exhibited an intensity distribution that deviated strongly from the $-3/2$ power law. This finding was later confirmed with the first redshift, equal to at least $z=0.835$, measured for GRB970508. Despite this result, the data from $CGRO$/BATSE and $Swift$/BAT indicate that long GRBs are indeed distributed isotropically, but the distribution of short GRBs is anisotropic. $Fermi$/GBM has detected 1669 GRBs up to date, and their sky distribution is examined in this paper. A number of statistical tests is applied: nearest neighbour analysis, fractal dimension, dipole and quadrupole moments of the distribution function decomposed into spherical harmonics, binomial test, and the two point angular correlation function. Monte Carlo benchmark testing of each test is performed in order to evaluate its reliability. It is found that short GRBs are distributed anisotropically ...

  16. Scaling analysis of the thermal-hydraulic test facility for the large break LOCA of KNGR

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Byong Jo; Kwon, Tae Soon; Song, Chul Hwa; Euh, Dong Jin; Chu, In Cheol; Cho, Hyoung Kyu; Park, Jong Kyun

    2001-03-01

    Korea Next Generation Reactor(KNGR) adopts a Direct Vessel Injection (DVI) system instead of conventional Cold Leg Injection (CLI) system. In this report, a scaling analysis for the steam-water test facility of KNGR with DVI under reflood phase of Loss of Coolant Accident(LBLOCA) is carried out. The major objectives of the test facility are to clarify the thermal hydraulics phenomena in the upper downcomer region and to provide experimental data for evaluating or validating relevant thermal hydraulic models and correlations of the best estimate codes. The test facility should be designed based on the appropriate scaling law so that the same thermal hydraulics phenomena is happened as in the case of prototype. For these, the investigations of previous scaling laws are carried out. And, in the present study, a new scaling approach, named the modified linear scaling, is developed for the design of a scaled-down experimental facility. Its velocity is scaled by a Wallis-type parameter and an aspect ratio of experimental facility is preserved with that of a prototype. The test facility is designed primarily by a volume scaling law and the area ratio of test facility is set to be 1/24.3. However, additional DVI nozzles are also installed at the elevation which is determined by the modified linear scaling law. It is for the scaling analysis of ECC bypass fraction. The cold leg, hot leg and DVI nozzles are additionally attached in the upper annulus downcomer region so that the UPTF counterpart test is possible.

  17. TRAC-PF1/MOD1 thermal-hydraulic predictions of JAERI Slab Core Test Facility gravity-feed tests

    Energy Technology Data Exchange (ETDEWEB)

    Gilbert, J.S.; Lin, J.C.

    1985-12-01

    The Transient Reactor Analysis Code, TRAC-PF1/MOD1, was used to analyze the Slab Core Test Facility gravity-feed tests (Runs 604, 605, 611, and 613) performed by the Japan Atomic Energy Research Institute. The objectives of the TRAC analysis are to compare the TRAC predictions with the test results and to assess the TRAC capability for simulating the core thermal-hydraulic behavior during the reflood phase of a large loss-of-coolant accident. In general, the TRAC-calculated results agree well with the data.

  18. Thermo-hydraulic analysis of the cool-down of the EDIPO test facility

    Science.gov (United States)

    Lewandowska, Monika; Bagnasco, Maurizio

    2011-09-01

    The first cool-down of the EDIPO (European DIPOle) test facility is foreseen to take place in 2011 by means of the existing 1.2 kW cryoplant at EPFL-CRPP Villigen. In this work, the thermo-hydraulic analysis of the EDIPO cool-down is performed in order both to assess the its duration and to optimize the procedure. The cool-down is driven by the helium flowing in both the outer cooling channel and in the windings connected hydraulically in parallel. We take into account limitations due to the pressure drop in the cooling circuit and the refrigerator capacity as well as heat conduction in the iron yoke. Two schemes of the hydraulic cooling circuit in the EDIPO windings are studied (coils connected in series and coils connected in parallel). The analysis is performed by means of an analytical model complemented by and numerical model. The results indicate that the cool-down to 5 K can be achieved in about 12 days.

  19. Ensemble Kalman filter versus ensemble smoother for assessing hydraulic conductivity via tracer test data assimilation

    Directory of Open Access Journals (Sweden)

    E. Crestani

    2013-04-01

    Full Text Available Estimating the spatial variability of hydraulic conductivity K in natural aquifers is important for predicting the transport of dissolved compounds. Especially in the nonreactive case, the plume evolution is mainly controlled by the heterogeneity of K. At the local scale, the spatial distribution of K can be inferred by combining the Lagrangian formulation of the transport with a Kalman-filter-based technique and assimilating a sequence of time-lapse concentration C measurements, which, for example, can be evaluated on site through the application of a geophysical method. The objective of this work is to compare the ensemble Kalman filter (EnKF and the ensemble smoother (ES capabilities to retrieve the hydraulic conductivity spatial distribution in a groundwater flow and transport modeling framework. The application refers to a two-dimensional synthetic aquifer in which a tracer test is simulated. Moreover, since Kalman-filter-based methods are optimal only if each of the involved variables fit to a Gaussian probability density function (pdf and since this condition may not be met by some of the flow and transport state variables, issues related to the non-Gaussianity of the variables are analyzed and different transformation of the pdfs are considered in order to evaluate their influence on the performance of the methods. The results show that the EnKF reproduces with good accuracy the hydraulic conductivity field, outperforming the ES regardless of the pdf of the concentrations.

  20. Results of hydraulic tests in wells DOE-1, 2, 3, Salt Valley, Grand County, Utah

    Science.gov (United States)

    Rush, F. Eugene; Hart, I.M.; Whitfield, M.S.; Giles, T.F.; D'Epagnier, T. E.

    1980-01-01

    Three exploratory wells were drilled for geological, geophysical, and hydrological purposes in Salt Valley, Grand County, Utah. Cap rock, salt, and interbeds of the Paradox Member of the Hermosa Formation of Middle Pennsylvanian age were penetrated. The observed depth below land surface of the cap rock-salt interface ranges from 163 meters (m) to 191 meters. Approximately the upper 100 meters of cap rock were unsaturated by ground water. Within the saturated part of the cap rock, hydraulic heads generally decrease with depth and southwestward. Ion concentrations generally increase with depth in the saturated cap rock.Hydraulic conductivity of cap rock, as determined from pumping tests, may be on the order of 5 x 10-3 meters per day; as a result, ground-water flow rates in the cap rock are probably very low. A carbon 14 specific activity for cap rock water yielded an uncorrected "age" of greater than 36,000 years. Salt and interbeds have hydraulic conductivities probably less than 1 x 10-4 meters per day.

  1. Testing the homogeneity of the Universe using gamma-ray bursts

    CERN Document Server

    Li, Ming-Hua

    2015-01-01

    In this paper, we study the homogeneity of the GRB distribution using a subsample of the Greiner GRB catalogue, which contains 314 objects with redshift $0test the results against the possible biases in redshift determination and the incompleteness of the Greiner sample, we also apply our analysis to the 244 GRBs discovered by Swift and the subsample presented by the Swift Gamma-Ray Burst Host Galaxy Legacy Survey (SHOALS). The real space two-point correlation function (2PCF) of GRBs, $\\xi(r),$ is calculated using a Landy-Szalay estimator. We perform a standard least-$\\chi^2$ fit to the measured 2PCFs of GRBs. We use the best-fit 2PCF to deduce a recently defined homogeneity scale. The homogeneity scale, $R_H$, is defined as the comoving radius of the sphere inside which the number of GRBs $N(

  2. Benchmark of the SixTrack-Fluka Active Coupling Against the SPS Scrapers Burst Test

    CERN Multimedia

    Mereghetti, A; Cerutti, F

    2014-01-01

    The SPS scrapers are a key ingredient for the clean injection into the LHC: they cut off halo particles quite close to the beam core (e.g.~3.5 sigma) just before extraction, to minimise the risk for quenches. The improved beam parameters as envisaged by the LHC Injectors Upgrade (LIU) Project required a revision of the present system, to assess its suitability and robustness. In particular, a burst (i.e. endurance) test of the scraper blades has been carried out, with the whole bunch train being scraped at the centre (worst working conditions). In order to take into account the effect of betatron and longitudinal beam dynamics on energy deposition patterns, and nuclear and Coulomb scattering in the absorbing medium onto loss patterns, the SixTrack and Fluka codes have been coupled, profiting from the best of the refined physical models they respectively embed. The coupling envisages an active exchange of tracked particles between the two codes at each turn, and an on-line aperture check in SixTrack, in order ...

  3. Integration of Tracer Test Data to Refine Geostatistical Hydraulic Conductivity Fields Using Sequential Self-Calibration Method

    Institute of Scientific and Technical Information of China (English)

    Bill X Hu; Jiang Xiaowei; Wan Li

    2007-01-01

    On the basis of local measurements of hydraulic conductivity, geostatistical methods have been found to be useful in heterogeneity characterization of a hydraulic conductivity field on a regional scale. However, the methods are not suited to directly integrate dynamic production data, such as,hydraulic head and solute concentration, into the study of conductivity distribution. These data, which record the flow and transport processes in the medium, are closely related to the spatial distribution of hydraulic conductivity. In this study, a three-dimensional gradient-based inverse method-the sequential self-calibration (SSC) method-is developed to calibrate a hydraulic conductivity field,initially generated by a geostatistical simulation method, conditioned on tracer test results. The SSC method can honor both local hydraulic conductivity measurements and tracer test data. The mismatch between the simulated hydraulic conductivity field and the reference true one, measured by its mean square error (MSE), is reduced through the SSC conditional study. In comparison with the unconditional results, the SSC conditional study creates the mean breakthrough curve much closer to the reference true curve, and significantly reduces the prediction uncertainty of the solute transport in the observed locations. Further, the reduction of uncertainty is spatially dependent, which indicates that good locations, geological structure, and boundary conditions will affect the efficiency of the SSC study results.

  4. Elastic-plastic analysis of the PVRC burst disk tests with comparison to the ASME code -- Primary stress limits

    Energy Technology Data Exchange (ETDEWEB)

    Jones, D.P.; Holliday, J.E.

    1999-02-01

    This paper provides a comparison between finite element analysis results and test data from the Pressure Vessel Research Council (PVRC) burst disk program. Testing sponsored by the PVRC over 20 years ago was done by pressurizing circular flat disks made from three different materials until failure by bursting. The purpose of this re-analysis is to investigate the use of finite element analysis (FEA) to assess the primary stress limits of the ASME Boiler and Pressure Vessel Code (1998) and to qualify the use of elastic-plastic (EP-FEA) for limit load calculations. The three materials tested represent the range of strength and ductility found in modern pressure vessel construction and include a low strength high ductility material, a medium strength medium ductility material, and a high strength low ductility low alloy material. Results of elastic and EP-FEA are compared to test data. Stresses from the elastic analyses are linearized for comparison of Code primary stress limits to test results. Elastic-plastic analyses are done using both best-estimate and elastic-perfectly plastic (EPP) stress-strain curves. Both large strain-large displacement (LSLD) and small strain-small displacement (SSSD) assumptions are used with the EP-FEA. Analysis results are compared to test results to evaluate the various analysis methods, models, and assumptions as applied to the bursting of thin disks.

  5. Oscillatory hydraulic testing as a strategy for NAPL source zone monitoring: Laboratory experiments

    Science.gov (United States)

    Zhou, YaoQuan; Cardiff, Michael

    2017-05-01

    Non-aqueous phase liquids (NAPLs) have a complex mode of transport in heterogeneous aquifers, which can result in pools and lenses of NAPLs (the ;source zone;) that are difficult to detect and can cause long-term contamination via slow dissolution into groundwater (the ;dissolved plume;). Characterizing the extent and evolution of NAPL contamination within the source zone is a useful strategy for designing and adapting appropriate remedial actions at many contaminated sites. As a NAPL flows into a given aquifer volume, the effective hydraulic conductivity (K) and specific storage (Ss) of the volume changes associated with the viscosity and compressibility of the impinging fluid, meaning that NAPL movement may be detectable with hydraulic testing. Recently, the use of oscillatory pumping tests - in which sinusoidal pumping variations are implemented and oscillatory pressure changes are detected at monitoring locations - has been suggested as a low-impact hydraulic testing strategy for characterizing aquifer properties (Cardiff et al., 2013; Zhou et al., 2016). Here, we investigate this strategy in an experimental laboratory sandbox where dyed vegetable oil is injected and allowed to migrate as a NAPL. Initial qualitative analyses demonstrate that measurable changes in pressure signal amplitude and phase provide clear evidence for NAPL plume emplacement and migration. Using the approach developed in Zhou et al. (2016), we then apply tomographic analyses to estimate the location of effective K changes (representing fluid changes) and their movement throughout time. This approach provides a method for monitoring ongoing NAPL movement without net extraction or injection of fluid, making it advantageous in field remediation applications.

  6. Thermal-hydraulic analysis of the semiscale Mod-1 blowdown heat transfer test series. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Cozzuol, J.M.

    1976-06-01

    Selected experimental thermal-hydraulic data from the recent Semiscale Mod-1 blowdown heat transfer test series are analyzed from an experimental viewpoint with emphasis on explaining those phenomena which influence core fluid behavior. Comparisons are made between the trends measured by the system instrumentation and the trends predicted by the RELAP4 computer code to aid in obtaining an understanding of the interactions between phenomena occurring in different parts of the system. The analyses presented in this report are valuable for evaluating the adequacy and improving the predictive capability of analytical models developed to predict the system response of a pressurized water reactor during a postulated loss-of-coolant accident (LOCA).

  7. Specifications for a coupled neutronics thermal-hydraulics SFR test case

    Science.gov (United States)

    Tassone, A.; Smirnov, A. D.; Tikhomirov, G. V.

    2017-01-01

    Coupling neutronics/thermal-hydraulics calculations for the design of nuclear reactors are a growing trend in the scientific community. This approach allows to properly represent the mutual feedbacks between the neutronic distribution and the thermal-hydraulics properties of the materials composing the reactor, details which are often lost when separate analysis are performed. In this work, a test case for a generation IV sodium-cooled fast reactor (SFR), based on the ASTRID concept developed by CEA, is proposed. Two sub-assemblies (SA) characterized by different fuel enrichment and layout are considered. Specifications for the test case are provided including geometrical data, material compositions, thermo-physical properties and coupling scheme details. Serpent and ANSYS-CFX are used as reference in the description of suitable inputs for the performing of the benchmark, but the use of other code combinations for the purpose of validation of the results is encouraged. The expected outcome of the test case are the axial distribution of volumetric power generation term (q‴), density and temperature for the fuel, the cladding and the coolant.

  8. Analysis of historic bursts and burst detection in water supply areas of different size

    NARCIS (Netherlands)

    Bakker, M.; Trietsch, E.A.; Vreeburg, J.H.G.; Rietveld, L.C.

    2014-01-01

    Pipe bursts in water distribution networks lead to water losses and a risk of damaging the urban environment. We studied hydraulic data and customer contact records of 44 real bursts for a better understanding of the phenomena. We found that most bursts were reported to the water company shortly aft

  9. A mini slug test method for determination of a local hydraulic conductivity of an unconfined sandy aquifer

    DEFF Research Database (Denmark)

    Hinsby, Klaus; Bjerg, Poul Løgstrup; Andersen, Lars J.;

    1992-01-01

    from level to level and thereby establish vertical profiles of the hydraulic conductivity. The head data from the test well are recorded with a 10 mm pressure transducer, and the initial head difference required is established by a small vacuum pump. The method described has provided 274 spatially......A new and efficient mini slug test method for the determination of local hydraulic conductivities in unconfined sandy aquifers is developed. The slug test is performed in a small-diameter (1 inch) driven well with a 0.25 m screen just above the drive point. The screened drive point can be driven...... distributed measurements of a local hydraulic conductivity at a tracer test site at Vejen, Denmark. The mini slug test results calculated by a modified Dax slug test analysing method, applying the elastic storativity in the Dax equations instead of the specific yield, are in good accordance with the results...

  10. Research on Simulation and Test of the Nonlinear Responses for the Hydraulic Shock Absorber

    Institute of Scientific and Technical Information of China (English)

    张建武; 刘延庆

    2003-01-01

    Basically on the multi-body system dynamics,the virtual prototype of the hydraulic shock absorber for the bench test is developed in the ADAMS environment.Dynamic behaviors of the absorber are studied by both computer simulation and real test.Numerical predictions of dynamic responses are produced by the established virtual prototype of the absorber and compared with experimental results.It has been shown from the comparison that the vibration behaviors of the prototype with hysteretic damping characteristics are considered to be more identical with the bench test results than those of the same prototype with piecewise linear damping properties are.The current virtual prototype of the shock absorber is correct and can be a developing terrace for the optimizing design of the absorber and matching capability of the whole car.

  11. Thermal-Hydraulic Issues in the ITER Toroidal Field Model Coil (TFMC) Test and Analysis

    Science.gov (United States)

    Zanino, R.; Bagnasco, M.; Fillunger, H.; Heller, R.; Savoldi Richard, L.; Suesser, M.; Zahn, G.

    2004-06-01

    The International Thermonuclear Experimental Reactor (ITER) Toroidal Field Model Coil (TFMC) was tested in the Toska facility of Forschungszentrum Karlsruhe during 2001 (standalone) and 2002 (in the background magnetic field of the LCT coil). The TFMC is a racetrack coil wound in five double pancakes on stainless steel radial plates using Nb3Sn dual-channel cable-in-conduit conductor (CICC) with a thin circular SS jacket. The coil was cooled by supercritical helium in forced convection at nominal 4.5 K and 0.5 MPa. Instrumentation, all outside the coil, included voltage taps, pressure and temperature sensors, as well as flow meters. Additionally, differential pressure drop measurement was available on the two pancakes DP1.1 and DP1.2, equipped with heaters. Two major thermal-hydraulic issues in the TFMC tests will be addressed here: 1) the pressure drop along heated pancakes and the comparison with friction factor correlations; 2) the quench initiation and propagation. Other thermal-hydraulic issues like heat generation and exchange in joints, radial plates, coil case, or the effects of the resistive heaters on the helium dynamics, have been already addressed elsewhere.

  12. Thermal hydraulics in the hot pool of Fast Breeder Test Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Padmakumar, G. [Fast Reactor Technology Group, Indira Gandhi Centre for Atomic Research, Kalpakkam, TN 603 102 (India)], E-mail: gpk@igcar.gov.in; Pandey, G.K.; Vaidyanathan, G. [Fast Reactor Technology Group, Indira Gandhi Centre for Atomic Research, Kalpakkam, TN 603 102 (India)

    2009-06-15

    Sodium cooled Fast Breeder Test Reactor (FBTR) of 40 MWt/13 MWe capacity is in operation at Kalpakkam, near Chennai. Presently it is operating with a core of 10.5 MWt. Knowledge of temperatures and flow pattern in the hot pool of FBTR is essential to assess the thermal stresses in the hot pool. While theoretical analysis of the hot pool has been conducted by a three-dimensional code to access the temperature profile, it involves tuning due to complex geometry, thermal stresses and vibration. With this in view, an experimental model was fabricated in 1/4 scale using acrylic material and tests were conducted in water. Initially hydraulic studies were conducted with ambient water maintaining Froude number similarity. After that thermal studies were conducted using hot and cold water maintaining Richardson similitude. In both cases Euler similarity was also maintained. Studies were conducted simulating both low and full power operating conditions. This paper discusses the model simulation, similarity criteria, the various thermal hydraulic studies that were carried out, the results obtained and the comparison with the prototype measurements.

  13. Ensemble Kalman filter versus ensemble smoother for assessing hydraulic conductivity via tracer test data assimilation

    Directory of Open Access Journals (Sweden)

    E. Crestani

    2012-11-01

    Full Text Available The significance of estimating the spatial variability of the hydraulic conductivity K in natural aquifers is relevant to the possibility of defining the space and time evolution of a non-reactive plume, since the transport of a solute is mainly controlled by the heterogeneity of K. At the local scale, the spatial distribution of K can be inferred by combining the Lagrangian formulation of the transport with a Kalman filter-based technique and assimilating a sequence of time-lapse concentration C measurements, which, for example, can be evaluated on-site through the application of a geophysical method. The objective of this work is to compare the ensemble Kalman filter (EnKF and the ensemble smoother (ES capabilities to retrieve the hydraulic conductivity spatial distribution in a groundwater flow and transport modeling framework. The application refers to a two-dimensional synthetic aquifer in which a tracer test is simulated. Moreover, since Kalman filter-based methods are optimal only if each of the involved variables fit to a Gaussian probability density function (pdf and since this condition may not be met by some of the flow and transport state variables, issues related to the non-Gaussianity of the variables are analyzed and different transformation of the pdfs are considered in order to evaluate their influence on the performance of the methods. The results show that the EnKF reproduces with good accuracy the hydraulic conductivity field, outperforming the ES regardless of the pdf of the concentrations.

  14. Flow-Log Analysis for Hydraulic Characterization of Selected Test Wells at the Indian Point Energy Center, Buchanan, New York

    Science.gov (United States)

    Williams, John H.

    2008-01-01

    Flow logs from 24 test wells were analyzed as part of the hydraulic characterization of the metamorphosed and fractured carbonate bedrock at the Indian Point Energy Center in Buchanan, New York. The flow logs were analyzed along with caliper, optical- and acoustic-televiewer, and fluid-resistivity and temperature logs to determine the character and distribution of fracture-flow zones and estimate their transmissivities and hydraulic heads. Many flow zones were associated with subhorizontal to shallow-dipping fractured zones, southeast-dipping bedding fractures, northwest-dipping conjugate fractures, or combinations of bedding and conjugate fractures. Flow-log analysis generally provided reasonable first-order estimates of flow-zone transmissivity and head differences compared with the results of conventional hydraulic-test analysis and measurements. Selected results of an aquifer test and a tracer test provided corroborating information in support of the flow-log analysis.

  15. Thermal-hydraulic tests of a recirculation cooling installation for the Rostov nuclear power station

    Science.gov (United States)

    Balunov, B. F.; Balashov, V. A.; Il'in, V. A.; Krayushnikov, V. V.; Lychakov, V. D.; Meshalkin, V. V.; Ustinov, A. N.; Shcheglov, A. A.

    2013-09-01

    Results obtained from thermal-hydraulic tests of the recirculation cooling installation used as part of the air cooling system under the containments of the Rostov nuclear power station Units 3 and 4 are presented. The operating modes of the installation during normal operation (air cooling on the surface of finned tubes), under the conditions of anticipated operational occurrences (air cooling and steam condensation from a steam-air mixture), and during an accident (condensation of pure steam) are considered. Agreement is obtained between the results of tests and calculations carried out according to the recommendations given in the relevant regulatory documents. A procedure of carrying out thermal calculation for the case of steam condensation from a steam-air mixture on the surface of fins is proposed. The possibility of efficient use of the recirculation cooling installation in the system for reducing emergency pressure under the containment of a nuclear power station is demonstrated.

  16. Hydraulic Shuttle Irradiation System (HSIS) Recently Installed in the Advanced Test Reactor (ATR)

    Energy Technology Data Exchange (ETDEWEB)

    A. Joseph Palmer; Gerry L. McCormick; Shannon J. Corrigan

    2010-06-01

    2010 International Congress on Advances in Nuclear Power Plants (ICAPP’10) ANS Annual Meeting Imbedded Topical San Diego, CA June 13 – 17, 2010 Hydraulic Shuttle Irradiation System (HSIS) Recently Installed in the Advanced Test Reactor (ATR) Author: A. Joseph Palmer, Mechanical Engineer, Irradiation Test Programs, 208-526-8700, Joe.Palmer@INL.gov Affiliation: Idaho National Laboratory P.O. Box 1625, MS-3840 Idaho Falls, ID 83415 INL/CON-10-17680 ABSTRACT Most test reactors are equipped with shuttle facilities (sometimes called rabbit tubes) whereby small capsules can be inserted into the reactor and retrieved during power operations. With the installation of Hydraulic Shuttle Irradiation System (HSIS) this capability has been restored to the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). The general design and operating principles of this system were patterned after the hydraulic rabbit at Oak Ridge National Laboratory’s (ORNL) High Flux Isotope Reactor (HFIR), which has operated successfully for many years. Using primary coolant as the motive medium the HSIS system is designed to simultaneously transport fourteen shuttle capsules, each 16 mm OD x 57 mm long, to and from the B-7 position of the reactor. The B-7 position is one of the higher flux positions in the reactor with typical thermal and fast (>1 Mev) fluxes of 2.8E+14 n/cm2/sec and 1.9E+14 n/cm2/sec respectively. The available space inside each shuttle is approximately 14 mm diameter x 50 mm long. The shuttle containers are made from titanium which was selected for its low neutron activation properties and durability. Shuttles can be irradiated for time periods ranging from a few minutes to several months. The Send and Receive Station (SRS) for the HSIS is located 2.5 m deep in the ATR canal which allows irradiated shuttles to be easily moved from the SRS to a wet loaded cask, or transport pig. The HSIS system first irradiated (empty) shuttles in September 2009 and has since completed

  17. Testing and Modeling for Energy Dissipation Behavior of Velocity and Displacement Dependent Hydraulic Damper

    Institute of Scientific and Technical Information of China (English)

    SUNG Wen-Pei; SHIH Ming-Hsiang

    2008-01-01

    A passive energy-dissipating device,velocity,and displacement dependent hydraulic damper (VDHD),is developed to reduce the seismic response of structure.This device is cemprised of a hydraulic jack,check valve,relief valve,and throttle valve.The numerical analysis model for SAP2000 nonlinear analysis program is proposed to simulate the energy-dissipating characteristics of VDHD.The analysis re-sults of this model compared with the seismic resistant tests reveal that this proposed model can accurately describe the actual energy-dissipating behavior of VDHD.The efficiency of VDHD is confirmed using this proposed model for carrying out numerical analyses of bare building,building added with bulking resistant bracing(BBR),and VDHD.The energy-dissipating capabilities of VDHD are performing excellent displace-ment and acceleration control with various ground magnitudes;being an energy absorber to absorb me-chanical energy in the structure and resist structural movement;and gathering the advantage of BRB.

  18. MODEL TESTS OF HYDRAULIC FLOW CONDITIONS IN THE VEGETATION BUILD-UP FISHWAY

    Directory of Open Access Journals (Sweden)

    Tomasz Tymiński

    2015-10-01

    Full Text Available Our engineering activity aiming at keeping ecological corridors in rivers are a difficult and complex issue that requires specialist knowledge in many disciplines. One of the installations for ensuring ecological continuum river are fishways, particularly their “near-natural” designs. They resemble mountain streams and creeks. Natural materials, such as wood, vegetation, gravel, stones and rocks are used for their construction. Design of hydraulic fishways based solely on the criteria of maximum speed vmax and parameter of unitary energy of water E, it does not give complete information about the effectiveness of these devices. In order to produce the optimal flow conditions for ichthyofauna, very useful are spatial structure research of hydraulic parameters, such as disorders of flow velocity field or distributions of the turbulence number Tu. The article presents an example of such a study, which the authors carried out on the model seminatural fishway in the water laboratory in Institute of Environmental Engineering in Wrocław. The results were used to assess the accuracy of the functioning of the fishway. The tested combination of “vegetated baffles” and “pools” in the fishway model was found to be optimal for the ichthyofauna. Vegetation build-up in fishways is an interesting and proecological alternative for “heavy” technical build-up.

  19. Measurement of basic thermal-hydraulic characteristics under the test facility and reactor conditions

    Energy Technology Data Exchange (ETDEWEB)

    Eduard A Boltenko; Victor P Sharov [Elektrogorsk Research and Engineering Center, EREC, Bezimyannaja Street, 6, Elektrogorsk, Moscow Region, 142530 (Russian Federation); Dmitriy E Boltenko [State Scientific Center of Russian Federation IPPE, Bondarenko Square, Obhinsk, Kaluga Region, 249020 (Russian Federation)

    2005-07-01

    Full text of publication follows: The nuclear power of Russia is based on the reactors of two types: water-water - WWER and uranium - graphite channel RBMK. The nuclear power development is possible with performance of the basic condition - level of nuclear power plants (NPP) safety should satisfy the rigid requirements. The calculated proof of NPPs safety made by means of thermal-hydraulic codes of improved estimation, verified on experimental data is the characteristic of this level. The data for code verification can be obtained at the integral facilities simulating a circulation circuit of NPP with the basic units and intended for investigation of circuit behaviour in transient and accident conditions. For verification of mathematical models in transient and accident conditions, development of physically reasonable methods for definition of the various characteristics of two-phase flow the experimental data, as the integrated characteristics of a flow, and data on the local characteristics and structure of a flow is necessary. For safety assurance of NPP it is necessary to monitor and determine the basic thermalhydraulic characteristics of reactor facility (RF). It is possible to refer coolant flow-rate, core input and output water temperature, heat-power. The description of the EREC works in the field completion and adaptation of certain methods with reference to measurements in dynamic modes of test facility conditions and development of methods for measurements of basic thermal-hydraulic characteristics of reactor facilities is presented in the paper. (authors)

  20. Testing hypotheses that link wood anatomy to cavitation resistance and hydraulic conductivity in the genus Acer.

    Science.gov (United States)

    Lens, Frederic; Sperry, John S; Christman, Mairgareth A; Choat, Brendan; Rabaey, David; Jansen, Steven

    2011-05-01

    • Vulnerability to cavitation and conductive efficiency depend on xylem anatomy. We tested a large range of structure-function hypotheses, some for the first time, within a single genus to minimize phylogenetic 'noise' and maximize detection of functionally relevant variation. • This integrative study combined in-depth anatomical observations using light, scanning and transmission electron microscopy of seven Acer taxa, and compared these observations with empirical measures of xylem hydraulics. • Our results reveal a 2 MPa range in species' mean cavitation pressure (MCP). MCP was strongly correlated with intervessel pit structure (membrane thickness and porosity, chamber depth), weakly correlated with pit number per vessel, and not related to pit area per vessel. At the tissue level, there was a strong correlation between MCP and mechanical strength parameters, and some of the first evidence is provided for the functional significance of vessel grouping and thickenings on inner vessel walls. In addition, a strong trade-off was observed between xylem-specific conductivity and MCP. Vessel length and intervessel wall characteristics were implicated in this safety-efficiency trade-off. • Cavitation resistance and hydraulic conductivity in Acer appear to be controlled by a very complex interaction between tissue, vessel network and pit characteristics.

  1. Neutron Tomography Using Mobile Neutron Generators for Assessment of Void Distributions in Thermal Hydraulic Test Loops

    Science.gov (United States)

    Andersson, P.; Bjelkenstedt, T.; Sundén, E. Andersson; Sjöstrand, H.; Jacobsson-Svärd, S.

    Detailed knowledge of the lateral distribution of steam (void) and water in a nuclear fuel assembly is of great value for nuclear reactor operators and fuel manufacturers, with consequences for both reactor safety and economy of operation. Therefore, nuclear relevant two-phase flows are being studied at dedicated thermal-hydraulic test loop, using two-phase flow systems ranging from simplified geometries such as heated circular pipes to full scale mock-ups of nuclear fuel assemblies. Neutron tomography (NT) has been suggested for assessment of the lateral distribution of steam and water in such test loops, motivated by a good ability of neutrons to penetrate the metallic structures of metal pipes and nuclear fuel rod mock-ups, as compared to e.g. conventional X-rays, while the liquid water simultaneously gives comparatively good contrast. However, these stationary test loops require the measurement setup to be mobile, which is often not the case for NT setups. Here, it is acknowledged that fast neutrons of 14 MeV from mobile neutron generators constitute a viable option for a mobile NT system. We present details of the development of neutron tomography for this purpose at the division of Applied Nuclear Physics at Uppsala University. Our concept contains a portable neutron generator, exploiting the fusion reaction of deuterium and tritium, and a detector with plastic scintillator elements designed to achieveadequate spatial and energy resolution, all mounted in a light-weight frame without collimators or bulky moderation to allow for a mobile instrument that can be moved about the stationary thermal hydraulic test sections. The detector system stores event-to-event pulse-height information to allow for discrimination based on the energy deposition in the scintillator elements.

  2. Variations in hydraulic conductivity with scale of measurement during aquifer tests in heterogeneous, porous carbonate rocks

    Science.gov (United States)

    Schulze-Makuch, Dirk; Cherkauer, Douglas S.

    Previous studies have shown that hydraulic conductivity of an aquifer seems to increase as the portion of the aquifer tested increases. To date, such studies have all relied on different methods to determine hydraulic conductivity at each scale of interest, which raises the possibility that the observed increase in hydraulic conductivity is due to the measurement method, not to the scale. This study analyzes hydraulic conductivity with respect to scale during individual aquifer tests in porous, heterogeneous carbonate rocks in southeastern Wisconsin, USA. Results from this study indicate that hydraulic conductivity generally increases during an individual test as the volume of aquifer impacted increases, and the rate of this increase is the same as the rate of increase determined by using different measurement methods. Thus, scale dependence of hydraulic conductivity during single tests does not depend on the method of measurement. This conclusion is supported by 22 of 26 aquifer tests conducted in porous-flow-dominated carbonate units within the aquifer. Instead, scale dependency is probably caused by heterogeneities within the aquifer, a conclusion supported by digital simulation. All of the observed types of hydraulic-conductivity variations with scale during individual aquifer tests can be explained by a conceptual model of a simple heterogeneous aquifer composed of high-conductivity zones within a low-conductivity matrix. Résumé Certaines études ont montré que la conductivité hydraulique d'un aquifère semble augmenter en même temps que la partie testée de l'aquifère s'étend. Jusqu'à présent, ces études ont toutes reposé sur des méthodes de détermination de la conductivité hydraulique différentes pour chaque niveau d'échelle, ce qui a conduit à penser que l'augmentation observée de la conductivité hydraulique pouvait être due aux méthodes de mesure et non à l'effet d'échelle. Cette étude analyse la conductivité hydraulique par

  3. Prevention and forecasting of rock burst hazards in coal mines

    Institute of Scientific and Technical Information of China (English)

    DOU Lin-ming; LU Cai-ping; MU Zong-long; GAO Ming-shi

    2009-01-01

    Rock bursts signify extreme behavior in coal mine strata and severely threaten the safety of the lives of miners, as well as the effectiveness and productivity of miners. In our study, an elastic-plastic-brittle model for the deformation and failure of coal/rock was established through theoretical analyses, laboratory experiments and field testing, simulation and other means, which perfectly predict sudden and delayed rock bursts. Based on electromagnetic emission (EME), acoustic emission (AE) and microseism (MS) effects in the process from deformation until impact rupture of coal-rock combination samples, a multi-parameter identification of premonitory technology was formed, largely depending on these three forms of emission. Thus a system of classification for forecasting rock bursts in space and time was established. We have presented the intensity weakening theory for rock bursts and a strong-soft-strong (3S) structural model for controlling the impact on rock surrounding roadways, with the objective of laying a theoretical foundation and establishing references for parameters for the weakening control of rock bursts. For the purpose of prevention, key technical parameters of directional hydraulic fracturing are revealed. Based on these results, as well as those from deep-hole controlled blasting in coal seams and rock, integrated control techniques were established and anti-impact hydraulic props, suitable for roadways subject to hazards from rockbursts have also been developed. These technologies have been widely used in most coal mines in China, subject to these hazards and have achieved remarkable economic and social benefits.

  4. Propeller tone bursts

    Science.gov (United States)

    Succi, G. P.; Munro, D. H.; Ingard, K. U.

    1983-01-01

    Intense high frequency (25-38 kHz) tone bursts have been observed in acoustic tests of a scale model of a general aviation propeller. The amplitude of the tone burst is approximately equal to the amplitude of the propeller noise signature. The conditions necessary for the production of these tone bursts are described. The experiments indicate that the origin of these bursts is a periodic flow oscillation on the suction surface of the propeller blade tips which may be due to the interaction between an oscillating shock wave and a laminar boundary layer.

  5. The Thermal-hydraulic Performance Test Report for the Non-instrumented Irradiation Test Rig of Annular Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Ho; Lee, Kang Hee; Shin, Chang Hwan

    2008-09-15

    This report presents the results of pressure drop test, vibration test and endurance test for the non-instrumented rig using the irradiation test in HANARO of the double cooled annular fuel which were designed and fabricated by KAERI. From the out-pile thermal hydraulic tests, corresponding to the pressure drop of 200 kPa is measured to be about 9.72 kg/sec. Vibration frequency for the non-instrumented rig ranges from 5.0 to 10.7 kg/s. RMS(Root Mean Square) displacement for non-instrumented rig is less than 11.73 m, and the maximum displacement is less than 54.87m. The flow rate for endurance test were 10.5 kg/s, which was 110% of 9.72 kg/s. And the endurance test was carried out for 3 days. The test results found not to the wear and satisfied to the limits of pressure drop, flow rate, vibration and wear in the non-instrumented rig. This test was performed at the FIVPET facility.

  6. Advanced neutron source reactor thermal-hydraulic test loop facility description

    Energy Technology Data Exchange (ETDEWEB)

    Felde, D.K.; Farquharson, G.; Hardy, J.H.; King, J.F.; McFee, M.T.; Montgomery, B.H.; Pawel, R.E.; Power, B.H.; Shourbaji, A.A.; Siman-Tov, M.; Wood, R.J.; Yoder, G.L.

    1994-02-01

    The Thermal-Hydraulic Test Loop (THTL) is a facility for experiments constructed to support the development of the Advanced Neutron Source Reactor (ANSR) at Oak Ridge National Laboratory. The ANSR is both cooled and moderated by heavy water and uses uranium silicide fuel. The core is composed of two coaxial fuel-element annuli, each of different diameter. There are 684 parallel aluminum-clad fuel plates (252 in the inner-lower core and 432 in the outer-upper core) arranged in an involute geometry that effectively creates an array of thin rectangular flow channels. Both the fuel plates and the coolant channels are 1.27 mm thick, with a span of 87 mm (lower core), 70 mm (upper core), and 507-mm heated length. The coolant flows vertically upwards at a mass flux of 27 Mg/m{sup 2}s (inlet velocity of 25 m/s) with an inlet temperature of 45{degrees}C and inlet pressure of 3.2 MPa. The average and peak heat fluxes are approximately 6 and 12 MW/m{sup 2}, respectively. The availability of experimental data for both flow excursion (FE) and true critical heat flux (CHF) at the conditions applicable to the ANSR is very limited. The THTL was designed and built to simulate a full-length coolant subchannel of the core, allowing experimental determination of thermal limits under the expected ANSR thermal-hydraulic conditions. For these experimental studies, the involute-shaped fuel plates of the ANSR core with the narrow 1.27-mm flow gap are represented by a narrow rectangular channel. Tests in the THTL will provide both single- and two-phase thermal-hydraulic information. The specific phenomena that are to be examined are (1) single-phase heat-transfer coefficients and friction factors, (2) the point of incipient boiling, (3) nucleate boiling heat-transfer coefficients, (4) two-phase pressure-drop characteristics in the nucleate boiling regime, (5) flow instability limits, and (6) CHF limits.

  7. FY 1993 progress report on the ANS thermal-hydraulic test loop operation and results

    Energy Technology Data Exchange (ETDEWEB)

    Siman-Tov, M.; Felde, D.K.; Farquharson, G. [and others

    1994-07-01

    The Thermal-Hydraulic Test Loop (THTL) is an experimental facility constructed to support the development of the Advanced Neutron Source Reactor (ANSR) at Oak Ridge National Laboratory (ORNL). Highly subcooled heavy-water coolant flows vertically upward at a very high mass flux of almost 27 MG/m{sup 2}-s. In a parallel fuel plate configuration as in the ANSR, the flow is subject to a potential excursive static-flow instability that can very rapidly lead to flow starvation and departure from nucleate boiling (DNB) in the ``hot channel``. The current correlations and experimental data bases for flow excursion (FE) and critical heat flux (CHF) seldom evaluate the specific combination of ANSR operating parameters. The THTL facility was designed and built to provide known thermal-hydraulic (T/H) conditions for a simulated full-length coolant subchannel of the ANS reactor core, thus facilitating experimental determination of FE and CHF thermal limits under expected ANSR T/H conditions. A series of FE tests with water flowing vertically upward was completed over a nominal heat flux range of 6 to 17 MW/m{sup 2}, a mass flux range of 8 to 28 Mg/m{sup 2}-s, an exit pressure range of 1.4 to 2.1 MPa, and an inlet temperature range of 40 to 50 C. FE experiments were also conducted using as ``soft`` a system as possible to secure a true FE phenomena (actual secondary burnout). True DNB experiments under similar conditions were also conducted. To the author`s knowledge, no other FE data have been reported in the literature to date that dover such a combination of conditions of high mass flux, high heat flux, and moderately high pressure.

  8. Magnetar Bursts

    Science.gov (United States)

    Kouveliotou, Chryssa

    2014-01-01

    The Fermi/Gamma-ray Burst Monitor (GBM) was launched in June 2008. During the last five years the instrument has observed several hundreds of bursts from 8 confirmed magnetars and 19 events from unconfirmed sources. I will discuss the results of the GBM magnetar burst catalog, expand on the different properties of their diverse source population, and compare these results with the bursting activity of past sources. I will then conclude with thoughts of how these properties fit the magnetar theoretical models.

  9. A test of the hydraulic vulnerability segmentation hypothesis in angiosperm and conifer tree species.

    Science.gov (United States)

    Johnson, Daniel M; Wortemann, Remi; McCulloh, Katherine A; Jordan-Meille, Lionel; Ward, Eric; Warren, Jeffrey M; Palmroth, Sari; Domec, Jean-Christophe

    2016-08-01

    Water transport from soils to the atmosphere is critical for plant growth and survival. However, we have a limited understanding about many portions of the whole-tree hydraulic pathway, because the vast majority of published information is on terminal branches. Our understanding of mature tree trunk hydraulic physiology, in particular, is limited. The hydraulic vulnerability segmentation hypothesis (HVSH) stipulates that distal portions of the plant (leaves, branches and roots) should be more vulnerable to embolism than trunks, which are nonredundant organs that require a massive carbon investment. In the current study, we compared vulnerability to loss of hydraulic function, leaf and xylem water potentials and the resulting hydraulic safety margins (in relation to the water potential causing 50% loss of hydraulic conductivity) in leaves, branches, trunks and roots of four angiosperms and four conifer tree species. Across all species, our results supported strongly the HVSH as leaves and roots were less resistant to embolism than branches or trunks. However, branches were consistently more resistant to embolism than any other portion of the plant, including trunks. Also, calculated whole-tree vulnerability to hydraulic dysfunction was much greater than vulnerability in branches. This was due to hydraulic dysfunction in roots and leaves at less negative water potentials than those causing branch or trunk dysfunction. Leaves and roots had narrow or negative hydraulic safety margins, but trunks and branches maintained positive safety margins. By using branch-based hydraulic information as a proxy for entire plants, much research has potentially overestimated embolism resistance, and possibly drought tolerance, for many species. This study highlights the necessity to reconsider past conclusions made about plant resistance to drought based on branch xylem only. This study also highlights the necessity for more research of whole-plant hydraulic physiology to better

  10. Testing and Performance Evaluation of Tractor Mounted Hydraulic Elevator for Mango Orchard

    Directory of Open Access Journals (Sweden)

    Kishor P. Kolhe

    2011-01-01

    Full Text Available Problem statement: The harvesting and pruning of horticultural crops is quite difficult due to their tallness. There are small hand tools available for harvesting and pruning. But these tools of harvesting and pruning are restricted due tree height, unavailability of trained labours for climbing and cost of operation etc. The mechanized machines are available; these are heavy and costly and are not suitable for low land holding, Indian marginal famers. Harvesting and pruning of horticultural crops with the available hand tool is very difficult. The labor has to climb on the tree by carrying these hand tools, which requires skill too. To overcome the above problems a Tractor Mounted Hydraulic Elevator (TMHE powered by tractor PTO, was tested for the mechanical harvesting and pruning of mango orchards using digital load cell, digital Vibration meter and digital Techometer for elevator stability study and pruner engine RPM measurements while in branch cutting respectively. The field performance of the above machine was carried out on plane mango plot, at Dr. Balasaheb Sawant Konkan Krishi Vidyapeeth, Dapoli, Dist: -Ratnagiri (Maharashtra, India. The machine was tested for the better stability at maximum reach position for harvesting and pruning of various mango varieties, like Alphanso, Totapuri etc. Approach: To reduce the harvesting /pruning cost, increase the harvesting/pruning efficiency and enhance the overall productivity of mango orchards. Also to use the traditional mechanized/ manual pruning tools with the developed tractor mounted hydraulic elevator. To develop and refine the power operated mechanism for marginal farmers. This stability study was carried out, by using strain gauge load cell (S-beam, having capacity of 2000 kg. The load cell guiding device was designed and fabricated for conducting the above experiments following standard material specifications of American society of testing material. The reaction on

  11. Test investigation on hydraulic losses in the discharge passage of an axial-flow pump

    Institute of Scientific and Technical Information of China (English)

    QIU Baoyun; CAO Haihong; JIANG Wei; GAO Zhaohui; WANG Fei

    2007-01-01

    In a discharge passage with a guide blade dis- charge circulation and secondary flow because of bend pipe, the flow in a 1-channel discharge passage of an axial flow pump is a complicated spiral flow. For a 2-channel passage, the discharge in the left channel is bigger than that in the fight, and the passage hydraulic losses are abnormal. In this study, the section current energy of the passage is accurately mea- sured and determined with a 5-hole probe. The hydraulic loss characteristics are determined and analyzed. The methods deducing the hydraulic losses are investigated. The results indicate that the passage hydraulic losses are not proportional to the flow discharge. Compared with a circular pipe, the hydraulic losses of a divergent discharge passage are smaller and the pump assembly efficiency is 10%-30% higher. As for the 1-channel passage, the axial-flow pump outlet circulation is usually too big; the passage hydraulic losses are also big, but a small circulation can slightly reduce hydraulic losses. As for the 2-channel passage, discharges in the two channels are not equal and the hydraulic losses increase. The outlet guide blade with a small discharge circulation or without circulation could reduce discharge passage hydraulic losses and increase pump assembly efficiency by 6%-11%.

  12. 液压泵试验台系统设计%Research of Test System of Hydraulic Pump

    Institute of Scientific and Technical Information of China (English)

    阳宝元; 黄志坚; 何曼

    2015-01-01

    One test system of hydraulic pump which includes hydraulic system, electronic control system and computer control system is de-signed, and some critical types of components are selected. The whole system is simple, practical which can reliably and quickly test perfor-mance parameters of hydraulic pump.%设计了一种液压泵试验台系统,包括液压系统、电控系统和计算机测控系统,对系统的相关元件进行了选型,整个系统简单实用,能可靠、快捷地对液压泵的性能参数进行测试。

  13. Post-test thermal-hydraulic analysis of two intermediate LOCA tests at the ROSA facility including uncertainty evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Freixa, J., E-mail: jordi@freixa.net [Paul Scherrer Institut (PSI) 5232 Villigen PSI (Switzerland); Kim, T.-W. [Paul Scherrer Institut (PSI) 5232 Villigen PSI (Switzerland); Manera, A. [University of Michigan, Ann Arbor, MI 48109 (United States)

    2013-11-15

    The OECD/NEA ROSA-2 project aims at addressing thermal-hydraulic safety issues relevant for light water reactors by building up an experimental database at the ROSA Large Scale Test Facility (LSTF). The ROSA facility simulates a PWR Westinghouse design with a four-loop configuration and a nominal power of 3423 MWth. Two intermediate break loss-of-coolant-accident (LOCA) experiments (Tests 1 and 2) have been carried out during 2010. The two tests were analyzed by using the US-NRC TRACE best estimate code, employing the same nodalization previously used for the simulation of small-break LOCA experiments of the ROSA-1 programme. A post-test calculation was performed for each test along with uncertainty analysis providing uncertainty bands for each relevant time trend. Uncertainties in the code modelling capabilities as well as in the initial and boundary conditions were taken into account, following the guidelines and lessons learnt through participation in the OECD/NEA BEMUSE programme. Two different versions of the TRACE code were used in the analysis, providing a qualitatively good prediction of the tests. However, the uncertainty analysis revealed differences between the performances of some models in the two versions. The most relevant parameters of the two experimental tests were falling within the computed uncertainty bands.

  14. Post-test thermal-hydraulic analysis of two intermediate LOCA tests at the ROSA facility including uncertainty evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Freixa, J.; Kim, T-W.; Manera, A. [Paul Scherrer Inst., Villigen (Switzerland)

    2011-07-01

    The OECD/NEA ROSA-2 project aims at addressing thermal-hydraulic safety issues relevant for light water reactors by building up an experimental database at the ROSA Large Scale Test Facility (LSTF). The ROSA facility simulates a PWR Westinghouse design with a four-loop configuration and a nominal power of 3423 MWth. Two intermediate break loss-of-coolant-accident (LOCA) experiments (Test 1 and 2) have been carried out during 2010. The two tests were analyzed by using the US-NRC TRACE best estimate code, employing the same nodalization previously used for the simulation of small-break LOCA experiments of the ROSA-1 program. A post-test calculation was performed for each test along with uncertainty analysis providing uncertainty bands for each relevant time trend. Uncertainties in the code modeling capabilities as well as in the initial and boundary conditions were taken into account, following the guidelines and lessons learnt through participation in the OECD/NEA BEMUSE program. Two different versions of the TRACE code were used in the analysis, providing a qualitatively good prediction of the tests. However, both versions showed deficiencies that need to be addressed. The most relevant parameters of the two experimental tests were falling within the computed uncertainty bands. (author)

  15. TRAC analysis of upper plenum thermal-hydraulic phenomena in the slab core test facility

    Energy Technology Data Exchange (ETDEWEB)

    Shire, P.; Boyack, B.

    1986-01-01

    The Transient Reactor Analysis Code, TRAC-PF1/MOD1, was used to analyze an upper-plenum model of the Slab Core Test Facility (SCTF). The SCTF is a two-dimensional thermal-hydraulic model of a pressurized water reactor used for core-reflood simulations by the Japan Atomic Energy Research Institute. The purpose of this study was to evaluate the effects of code input-model refinements on the comparison between TRAC calculations and test data. Of particular interest were the comparisons of upper-plenum liquid levels and of the distributions of liquid radially across the upper-plenum. The upper-plenum region was selected for study. The test data indicated that the liquid level responded to the onset of emergency core cooling (ECC) by rising in the upper-plenum immediately when injection occurred. However, the early TRAC results indicated no significant liquid level increase until approx.300 s after the injection. Test data also indicated a liquid gradient rising toward the hot-leg entrance, but none was observed with TRAC.

  16. Preliminary Design of Large Scale Sodium Thermal-Hydraulic Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Tae Ho; Kim, Tae Joon; Eoh, Jae Hyuk; Lee, Hyeong Yeon; Lee, Jae Han; Jeong, Ji Young; Park, Su Ki; Han, Ji Woong; Yoo, Yong Hwan; Lee, Yong Bum [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2009-10-15

    A large scale sodium thermal-hydraulic test facility is being designed for verification of the advanced design concept of the passive decay heat removal circuit (PDRC) in a medium- or large-sized pool-type SFR. In the test, its cooling capability during the long- and short-term periods after the reactor trip will be evaluated, and also the produced experimental data will be utilized for the assessment and verification of the safety and performance analysis codes. Starting with the preliminary design of the test facility this year using KALIMER-600 as a reference reactor, the basic and the detailed designs will be made through 2011-2012 based on the demonstration reactor which is intended to be constructed by 2028 according to a long-term national SFR development plan. The installation is scheduled to be completed by the end of 2013, and the main experiments will commence from 2015 after the startup test in 2014. This paper briefly introduces the preliminary design features which were produced as a first step to assess the appropriateness of the facility design methodology.

  17. Interpretation of Flow Logs from Nevada Test Site Boreholes to Estimate Hydraulic Conductivity Using Numerical Simulations Constrained by Single-Well Aquifer Tests

    Science.gov (United States)

    Garcia, C. Amanda; Halford, Keith J.; Laczniak, Randell J.

    2010-01-01

    Hydraulic conductivities of volcanic and carbonate lithologic units at the Nevada Test Site were estimated from flow logs and aquifer-test data. Borehole flow and drawdown were integrated and interpreted using a radial, axisymmetric flow model, AnalyzeHOLE. This integrated approach is used because complex well completions and heterogeneous aquifers and confining units produce vertical flow in the annular space and aquifers adjacent to the wellbore. AnalyzeHOLE simulates vertical flow, in addition to horizontal flow, which accounts for converging flow toward screen ends and diverging flow toward transmissive intervals. Simulated aquifers and confining units uniformly are subdivided by depth into intervals in which the hydraulic conductivity is estimated with the Parameter ESTimation (PEST) software. Between 50 and 150 hydraulic-conductivity parameters were estimated by minimizing weighted differences between simulated and measured flow and drawdown. Transmissivity estimates from single-well or multiple-well aquifer tests were used to constrain estimates of hydraulic conductivity. The distribution of hydraulic conductivity within each lithology had a minimum variance because estimates were constrained with Tikhonov regularization. AnalyzeHOLE simulated hydraulic-conductivity estimates for lithologic units across screened and cased intervals are as much as 100 times less than those estimated using proportional flow-log analyses applied across screened intervals only. Smaller estimates of hydraulic conductivity for individual lithologic units are simulated because sections of the unit behind cased intervals of the wellbore are not assumed to be impermeable, and therefore, can contribute flow to the wellbore. Simulated hydraulic-conductivity estimates vary by more than three orders of magnitude across a lithologic unit, indicating a high degree of heterogeneity in volcanic and carbonate-rock units. The higher water transmitting potential of carbonate-rock units relative

  18. Interpretation of Flow Logs from Nevada Test Site Boreholes to Estimate Hydraulic conductivity Using Numerical Simulations Constrained by Single-Well Aquifer Tests

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, C. Amanda; Halford, Keith J.; Laczniak, Randell J.

    2010-02-12

    Hydraulic conductivities of volcanic and carbonate lithologic units at the Nevada Test Site were estimated from flow logs and aquifer-test data. Borehole flow and drawdown were integrated and interpreted using a radial, axisymmetric flow model, AnalyzeHOLE. This integrated approach is used because complex well completions and heterogeneous aquifers and confining units produce vertical flow in the annular space and aquifers adjacent to the wellbore. AnalyzeHOLE simulates vertical flow, in addition to horizontal flow, which accounts for converging flow toward screen ends and diverging flow toward transmissive intervals. Simulated aquifers and confining units uniformly are subdivided by depth into intervals in which the hydraulic conductivity is estimated with the Parameter ESTimation (PEST) software. Between 50 and 150 hydraulic-conductivity parameters were estimated by minimizing weighted differences between simulated and measured flow and drawdown. Transmissivity estimates from single-well or multiple-well aquifer tests were used to constrain estimates of hydraulic conductivity. The distribution of hydraulic conductivity within each lithology had a minimum variance because estimates were constrained with Tikhonov regularization. AnalyzeHOLE simulated hydraulic-conductivity estimates for lithologic units across screened and cased intervals are as much as 100 times less than those estimated using proportional flow-log analyses applied across screened intervals only. Smaller estimates of hydraulic conductivity for individual lithologic units are simulated because sections of the unit behind cased intervals of the wellbore are not assumed to be impermeable, and therefore, can contribute flow to the wellbore. Simulated hydraulic-conductivity estimates vary by more than three orders of magnitude across a lithologic unit, indicating a high degree of heterogeneity in volcanic and carbonate-rock units. The higher water transmitting potential of carbonate-rock units relative

  19. Identification of groundwater flow parameters using reciprocal data from hydraulic interference tests

    Science.gov (United States)

    Marinoni, Marianna; Delay, Frederick; Ackerer, Philippe; Riva, Monica; Guadagnini, Alberto

    2016-08-01

    We investigate the effect of considering reciprocal drawdown curves for the characterization of hydraulic properties of aquifer systems through inverse modeling based on interference well testing. Reciprocity implies that drawdown observed in a well B when pumping takes place from well A should strictly coincide with the drawdown observed in A when pumping in B with the same flow rate as in A. In this context, a critical point related to applications of hydraulic tomography is the assessment of the number of available independent drawdown data and their impact on the solution of the inverse problem. The issue arises when inverse modeling relies upon mathematical formulations of the classical single-continuum approach to flow in porous media grounded on Darcy's law. In these cases, introducing reciprocal drawdown curves in the database of an inverse problem is equivalent to duplicate some information, to a certain extent. We present a theoretical analysis of the way a Least-Square objective function and a Levenberg-Marquardt minimization algorithm are affected by the introduction of reciprocal information in the inverse problem. We also investigate the way these reciprocal data, eventually corrupted by measurement errors, influence model parameter identification in terms of: (a) the convergence of the inverse model, (b) the optimal values of parameter estimates, and (c) the associated estimation uncertainty. Our theoretical findings are exemplified through a suite of computational examples focused on block-heterogeneous systems with increased complexity level. We find that the introduction of noisy reciprocal information in the objective function of the inverse problem has a very limited influence on the optimal parameter estimates. Convergence of the inverse problem improves when adding diverse (nonreciprocal) drawdown series, but does not improve when reciprocal information is added to condition the flow model. The uncertainty on optimal parameter estimates is

  20. Testing black hole neutrino-dominated accretion discs for long-duration gamma-ray bursts

    CERN Document Server

    Song, Cui-Ying; Gu, Wei-Min; Tian, Jian-Xiang

    2016-01-01

    Long-duration gamma-ray bursts (LGRBs) are generally considered to originate from the massive collapsars. It is believed that the central engine of gamma-ray bursts (GRBs) is a neutrino-dominated accretion flow (NDAF) around a rotating stellar-mass black hole (BH). The neutrino annihilation above the NDAF is a feasible mechanism to power GRB. In this work, we analyse the distributions of the isotropic gamma-ray radiated energy and jet kinetic energy of 48 LGRBs. According to the NDAF and fireball models, we estimate the mean accreted masses of LGRBs in our sample to investigate whether the NDAFs can power LGRBs with the reasonable BH parameters and conversion efficiency of neutrino annihilation. The results indicate that most of the values of the accreted masses are less than $5~M_\\odot$ for the extreme Kerr BHs and high conversion efficiency. It suggests that the NDAFs may be suitable for most of LGRBs except for some extremely high energy sources.

  1. Testing black hole neutrino-dominated accretion discs for long-duration gamma-ray bursts

    Science.gov (United States)

    Song, Cui-Ying; Liu, Tong; Gu, Wei-Min; Tian, Jian-Xiang

    2016-05-01

    Long-duration gamma-ray bursts (LGRBs) are generally considered to originate from the massive collapsars. It is believed that the central engine of gamma-ray bursts (GRBs) is a neutrino-dominated accretion flow (NDAF) around a rotating stellar-mass black hole (BH). The neutrino annihilation above the NDAF is a feasible mechanism to power GRB. In this work, we analyse the distributions of the isotropic gamma-ray-radiated energy and jet kinetic energy of 48 LGRBs. According to the NDAF and fireball models, we estimate the mean accreted masses of LGRBs in our sample to investigate whether the NDAFs can power LGRBs with the reasonable BH parameters and conversion efficiency of neutrino annihilation. The results indicate that most of the values of the accreted masses are less than 5 M⊙ for the extreme Kerr BHs and high conversion efficiency. It suggests that the NDAFs may be suitable for most of LGRBs except for some extremely high energy sources.

  2. Hydraulic Characterization of Overpressured Tuffs in Central Yucca Flat, Nevada Test Site, Nye County, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    K.J. Halford; R.J. Laczniak; D.L. Galloway

    2005-10-07

    A sequence of buried, bedded, air-fall tuffs has been used extensively as a host medium for underground nuclear tests detonated in the central part of Yucca Flat at the Nevada Test Site. Water levels within these bedded tuffs have been elevated hundreds of meters in areas where underground nuclear tests were detonated below the water table. Changes in the ground-water levels within these tuffs and changes in the rate and distribution of land-surface subsidence above these tuffs indicate that pore-fluid pressures have been slowly depressurizing since the cessation of nuclear testing in 1992. Declines in ground-water levels concurrent with regional land subsidence are explained by poroelastic deformation accompanying ground-water flow as fluids pressurized by underground nuclear detonations drain from the host tuffs into the overlying water table and underlying regional carbonate aquifer. A hydraulic conductivity of about 3 x 10-6 m/d and a specific storage of 9 x 10-6 m-1 are estimated using ground-water flow models. Cross-sectional and three-dimensional ground-water flow models were calibrated to measured water levels and to land-subsidence rates measured using Interferometric Synthetic Aperture Radar. Model results are consistent and indicate that about 2 million m3 of ground water flowed from the tuffs to the carbonate rock as a result of pressurization caused by underground nuclear testing. The annual rate of inflow into the carbonate rock averaged about 0.008 m/yr between 1962 and 2005, and declined from 0.005 m/yr in 2005 to 0.0005 m/yr by 2300.

  3. Hydraulic characterization of overpressured tuffs in central Yucca Flat, Nevada Test Site, Nye County, Nevada

    Science.gov (United States)

    Halford, Keith J.; Laczniak, Randell J.; Galloway, Devin L.

    2005-01-01

    A sequence of buried, bedded, air-fall tuffs has been used extensively as a host medium for underground nuclear tests detonated in the central part of Yucca Flat at the Nevada Test Site. Water levels within these bedded tuffs have been elevated hundreds of meters in areas where underground nuclear tests were detonated below the water table. Changes in the ground-water levels within these tuffs and changes in the rate and distribution of land-surface subsidence above these tuffs indicate that pore-fluid pressures have been slowly depressurizing since the cessation of nuclear testing in 1992. Declines in ground-water levels concurrent with regional land subsidence are explained by poroelastic deformation accompanying ground-water flow as fluids pressurized by underground nuclear detonations drain from the host tuffs into the overlying water table and underlying regional carbonate aquifer. A hydraulic conductivity of about 3 x 10-6 m/d and a specific storage of 9 x 10-6 m-1 are estimated using ground-water flow models. Cross-sectional and three-dimensional ground-water flow models were calibrated to measured water levels and to land-subsidence rates measured using Interferometric Synthetic Aperture Radar. Model results are consistent and indicate that about 2 million m3 of ground water flowed from the tuffs to the carbonate rock as a result of pressurization caused by underground nuclear testing. The annual rate of inflow into the carbonate rock averaged about 0.008 m/yr between 1962 and 2005, and declined from 0.005 m/yr in 2005 to 0.0005 m/yr by 2300.

  4. Test case specifications for coupled neutronics-thermal hydraulics calculation of Gas-cooled Fast Reactor

    Science.gov (United States)

    Osuský, F.; Bahdanovich, R.; Farkas, G.; Haščík, J.; Tikhomirov, G. V.

    2017-01-01

    The paper is focused on development of the coupled neutronics-thermal hydraulics model for the Gas-cooled Fast Reactor. It is necessary to carefully investigate coupled calculations of new concepts to avoid recriticality scenarios, as it is not possible to ensure sub-critical state for a fast reactor core under core disruptive accident conditions. Above mentioned calculations are also very suitable for development of new passive or inherent safety systems that can mitigate the occurrence of the recriticality scenarios. In the paper, the most promising fuel material compositions together with a geometry model are described for the Gas-cooled fast reactor. Seven fuel pin and fuel assembly geometry is proposed as a test case for coupled calculation with three different enrichments of fissile material in the form of Pu-UC. The reflective boundary condition is used in radial directions of the test case and vacuum boundary condition is used in axial directions. During these condition, the nuclear system is in super-critical state and to achieve a stable state (which is numerical representation of operational conditions) it is necessary to decrease the reactivity of the system. The iteration scheme is proposed, where SCALE code system is used for collapsing of a macroscopic cross-section into few group representation as input for coupled code NESTLE.

  5. Comparison of System Identification Techniques for the Hydraulic Manipulator Test Bed (HMTB)

    Science.gov (United States)

    Morris, A. Terry

    1996-01-01

    In this thesis linear, dynamic, multivariable state-space models for three joints of the ground-based Hydraulic Manipulator Test Bed (HMTB) are identified. HMTB, housed at the NASA Langley Research Center, is a ground-based version of the Dexterous Orbital Servicing System (DOSS), a representative space station manipulator. The dynamic models of the HMTB manipulator will first be estimated by applying nonparametric identification methods to determine each joint's response characteristics using various input excitations. These excitations include sum of sinusoids, pseudorandom binary sequences (PRBS), bipolar ramping pulses, and chirp input signals. Next, two different parametric system identification techniques will be applied to identify the best dynamical description of the joints. The manipulator is localized about a representative space station orbital replacement unit (ORU) task allowing the use of linear system identification methods. Comparisons, observations, and results of both parametric system identification techniques are discussed. The thesis concludes by proposing a model reference control system to aid in astronaut ground tests. This approach would allow the identified models to mimic on-orbit dynamic characteristics of the actual flight manipulator thus providing astronauts with realistic on-orbit responses to perform space station tasks in a ground-based environment.

  6. Handbook of hydraulic fluid technology

    CERN Document Server

    Totten, George E

    2011-01-01

    ""The Handbook of Hydraulic Fluid Technology"" serves as the foremost resource for designing hydraulic systems and for selecting hydraulic fluids used in engineering applications. Featuring new illustrations, data tables, as well as practical examples, this second edition is updated with essential information on the latest hydraulic fluids and testing methods. The detailed text facilitates unparalleled understanding of the total hydraulic system, including important hardware, fluid properties, and hydraulic lubricants. Written by worldwide experts, the book also offers a rigorous overview of h

  7. Thermal-Hydraulics and Electrochemistry of a Boiling Solution in a Porous Sludge Pile A Test Methodology

    Energy Technology Data Exchange (ETDEWEB)

    R.F. Voelker

    2001-05-03

    When boiling occurs in a pile of porous corrosion products (sludge), chemical species can concentrate. These species can react with the corrosion products and transform the sludge into a rock hard mass and/or create a corrosive environment. In-situ measurements are required to improve the understanding of this process, and the thermal-hydraulic and electrochemical environment in the pile. A test method is described that utilizes a water heated instrumented tube array in an autoclave to perform the in-situ measurements. As a proof of method feasibility, tests were performed in an alkaline phosphate solution. The test data is discussed. Temperature changes and electrochemical potential shifts were used to indicate when chemicals concentrate and if/when the pile hardens. Post-test examinations confirmed hardening occurred. Experiments were performed to reverse the hardening process. A one-dimensional model, utilizing capillary forces, was developed to understand the thermal-hydraulic measurements.

  8. Validation of the thermal-hydraulic system code ATHLET based on selected pressure drop and void fraction BFBT tests

    Energy Technology Data Exchange (ETDEWEB)

    Di Marcello, Valentino, E-mail: valentino.marcello@kit.edu; Escalante, Javier Jimenez; Espinoza, Victor Sanchez

    2015-07-15

    Highlights: • Simulation of BFBT-BWR steady-state and transient tests with ATHLET. • Validation of thermal-hydraulic models based on pressure drops and void fraction measurements. • TRACE system code is used for the comparative study. • Predictions result in a good agreement with the experiments. • Discrepancies are smaller or comparable with respect to the measurements uncertainty. - Abstract: Validation and qualification of thermal-hydraulic system codes based on separate effect tests are essential for the reliability of numerical tools when applied to nuclear power plant analyses. To this purpose, the Institute for Neutron Physics and Reactor Technology (INR) at the Karlsruhe Institute of Technology (KIT) is involved in various validation and qualification activities of different CFD, sub-channel and system codes. In this paper, the capabilities of the thermal-hydraulic code ATHLET are assessed based on the experimental results provided within the NUPEC BFBT benchmark related to key Boiling Water Reactors (BWR) phenomena. Void fraction and pressure drops measurements in the BFBT bundle performed under steady-state and transient conditions which are representative for e.g. turbine trip and recirculation pump trip events, are compared with the numerical results of ATHLET. The comparison of code predictions with the BFBT data has shown good agreement given the experimental uncertainty and the results are consistent with the trends obtained with similar thermal-hydraulic codes.

  9. Nondestructive testing of rocket engine injector panel using ultrasonic burst phase thermography

    Science.gov (United States)

    Chen, Dapeng; Zhang, Cunlin; Wu, Naiming; Zeng, Zhi; Xing, Chunfei; Li, Yue; Zhao, Shibin; Ning, Tao

    2010-10-01

    As the key parts of the liquid rocket oxyhydrogen engine, the injector panel is a kind of transpiration material, which is braided and Sintered with stainless steel wire. If some hidden delaminition defects that are difficult to detect appear in the process of Sintering and rolling, a significant safety problem would occur. In this paper, we use the Ultrasonic Burst Phase Thermography (UBP) to detect the delamination defects in the injector panel, UBP is a rapid and reliable nondestructive technique derived from Ultrasonic Lock-in Thermography(ULT). It uses a controllable, adjustable ultrasonic burst as the heat source to stimulate the sample, the defects within the material are revealed through their heat generation caused by friction, clapping and thermoelastic effect, as the resulting surface temperature distribution is observed by an infrared camera. The original thermal images sequence is processed by Fast Fourier Transformation to obtain the phase information of the defects. In the experiments of the delamination sample, the UBP realized the selective heating of delamination defects in the injector panel, and the signal to noise of phase image is higher than the original thermal image because the phase information can not be disturbed by the initial conditions (such as the reflective surface of sample). However, the result of the detection of flat bottom hole transpiration panel sample reflects that UBP is not appropriate for the detection of this kind of defects, because it is difficult to induce frictional heating of flat bottom holes. As contrast, Flash Pulse Thermography is used to detect the flat bottom holes, all of the holes of different depth and sizes can be seen distinctly. The results show that PT is more appropriate for the detection of flat bottom holes defects than UBP, therefore, it is important to select the appropriate excitation method according to different defects.

  10. Deformation Characterization of Friction-Stir-Welded Tubes by Hydraulic Bulge Testing

    Science.gov (United States)

    Pang, Q.; Hu, Z. L.; Pan, X.; Zuo, X. Q.

    2014-10-01

    In this article, the large-diameter thin-walled aluminum alloy tubes were produced using a hybrid process combining friction-stir welding (FSW) and spinning. For this novel process, rolled aluminum alloy sheets with a thickness about 2-3 times the wall thickness of target tube, were FSW to form cylinders, and then the cylinders were subjected to spinning to get thin-walled aluminum alloy tubes. Both experimental and simulation study were conducted to investigate the deformation characterization of the FSW tube during hydraulic bulge testing, and the stress and strain states and thickness distribution of the FSW tube were investigated. It was found that the common defects of FSW tube can be significantly improved by specific welding devices. The ductility of the tube is considerably improved with nearly two times higher bulge ratio than as-spun tube after annealing treatment at 300°C. But the annealed tube still shows a high nonuniform wall thickness distribution due to the inhomogeneous deformation characteristics. With increasing deformation of the tube, the gap between the hoop and axial stress for the weld and base metal (BM) decreases. However, the hoop and axial stress of the weld are always greater than those of the BM at the same pressure.

  11. Thermal-hydraulic analysis for changing feedwater check valve leakage rate testing methodology

    Energy Technology Data Exchange (ETDEWEB)

    Fuller, R.; Harrell, J.

    1996-12-01

    The current design and testing requirements for the feedwater check valves (FWCVs) at the Grand Gulf Nuclear Station are established from original licensing requirements that necessitate extremely restrictive air testing with tight allowable leakage limits. As a direct result of these requirements, the original high endurance hard seats in the FWCVs were modified with elastomeric seals to provide a sealing surface capable of meeting the stringent air leakage limits. However, due to the relatively short functional life of the elastomeric seals compared to the hard seats, the overall reliability of the sealing function actually decreased. This degraded performance was exhibited by frequent seal failures and subsequent valve repairs. The original requirements were based on limited analysis and the belief that all of the high energy feedwater vaporized during the LOCA blowdown. These phenomena would have resulted in completely voided feedwater lines and thus a steam environment within the feedwater leak pathway. To challenge these criteria, a comprehensive design basis accident analysis was developed using the RELAP5/MOD3.1 thermal-hydraulic code. Realistic assumptions were used to more accurately model the post-accident fluid conditions within the feedwater system. The results of this analysis demonstrated that no leak path exists through the feedwater lines during the reactor blowdown phase and that sufficient subcooled water remains in various portions of the feedwater piping to form liquid water loop seals that effectively isolate this leak path. These results provided the bases for changing the leak testing requirements of the FWCVs from air to water. The analysis results also established more accurate allowable leakage limits, determined the real effective margins associated with the FWCV safety functions, and led to design changes that improved the overall functional performance of the valves.

  12. Test and application of hydraulic expansion bolts in a roadway under goaf with ultra-close separation

    Institute of Scientific and Technical Information of China (English)

    Wang Xiangyu; Bai Jianbiao; Guo Guanlong; Yu Yang

    2014-01-01

    The roof of a roadway under goaf with ultra-close separation consists of thin rock strata and rocks caving in upper goaf. Influenced by the mining of the upper coal seam, the roof is loose and broken, and its integ-rity is poor. Resin anchored bolts cannot provide an effective anchoring force in such roof conditions. By conducting free expansion tests and field pull-out tests on a hydraulic expansion bolt, this study has ana-lyzed the influencing factors and laws of radial expansion and anchoring force changes in the rod body. This has revealed the anchoring mechanism of such bolts, and has obtained reasonable water injection pressures and suitable drilling diameters (which are 20–25 MPa and 32–35 mm respectively) for the hydraulic expansion bolt (u28 mm) used in these tests. Based on pull-out tests at different interlayer spacing, the applicability of hydraulic expansion bolts had been verified for controlling the roof of road-ways under goaf with ultra-close distance. Combined with the deformation and failure characteristics of the test roadway roof, this paper proposes a united roof-control technology based on the use of hydraulic expansion bolts and advancing intubation for the roof. Engineering practice indicated that the roof of the test roadway did not generate leaking and caving phenomenon, and the amount of roof deformation was controlled to within 150 mm. Maintenance of the roadway roof has been improved significantly, which ensures safe mining in coal seams with ultra-close separation.

  13. [Development and Validation of a Fully Automated, Experimental Set-Up for Ex-Vivo Burst Pressure Testing after Surgical Vessel Closure].

    Science.gov (United States)

    Wallimann, Herbert; Menges, Pia; Hausen, Bernard; Linder, Albert

    2017-06-20

    Background A growing number of operations are performed using minimally invasive techniques. Therefore, a lot of new requirements must be met by the staplers currently available. At the present time, the most widely used methods of minimally invasive vascular occlusion involve high-frequency energy, clips, and staplers. The most important quality parameter is burst pressure, which is measured with a variety of experimental set-ups, all of which are subject to criticism. With this study, we want to introduce a fully automated vascular burst pressure measuring system that largely mimics physiological conditions. An important feature of this set-up is the detection of very early leakage from the staple line (FAIR Leakage = First Appearance of Leakage requiring Intervention). Material and Methods Burst pressure was measured in vessel segments of porcine common carotid arteries. For vascular occlusion, we used the stapler device Micro Cutter XCHANGE(®) by DexteraSurgical. Prior to closure, the vessel was filled to a pressure of 80 mmHg. The pressure was increased at a defined flow rate. Burst pressure was defined as staple line leakage requiring intervention. Results and Validation 30 staple lines were examined. The average burst pressure visually determined by two independent investigators was 515.8 mmHg ± 236.3 mmHg. Maximal burst pressure was 911 mmHg, and minimal burst pressure 80 mmHg. The average burst pressure detected electronically was 511.8 mmHg ± 239.1 mmHg. Statistically, there was a highly significant correlation of visually and electronically detected burst pressures. Conclusion This is the first experimental set-up for a systematic burst pressure test that is fully automated and therefore eliminates any bias related to the investigator. The experimental set-up with a defined intravascular pressure prior to closure and the use of a liquid with blood-like viscosity enabled us to largely mimic intraoperative conditions. Since burst

  14. Hydraulic impact end effector final test report. Automation and robotics section, ER/WM-AT Program

    Energy Technology Data Exchange (ETDEWEB)

    Couture, S.

    1994-02-18

    One tool being developed for dislodging and fragmenting the hard salt cake waste in the single-shell nuclear waste tanks at the Hanford Reservation near Richland, Washington, is the hydraulic impact end effector (HIEE). This total operates by discharging 11-in. slugs of water at ultrahigh pressures. The HIEE was designed, built, and initially tested in 1992. Work in 1993 included advanced developments of the HIEE to further investigate its fragmentation abilities and to determine more effective operating procedures. These tests showed that more fragmentation can be achieved by increasing the charge pressure of 40 kpsi to 55 kpsi and by the use of different operating procedures. The size of the material and the impact energy of the water slug fired from the HIEE are believed to be major factors in material fragmentation. The material`s ability to fracture also appears to depend on the distance a fracture or crack line must travel to a free surface. Thus, larger material is more difficult to fracture than smaller material. Discharge pressures of 40 kpsi resulted in little penetration or fracturing of the material. At 55 kpsi, however, the size and depth of the fractures increased. Nozzle geometry had a significant effect on fragment size and quantity. Fragmentation was about an order of magnitude greater when the HIEE was discharged into drilled holes rather than onto the material surface. Since surface shots tend to create craters, a multi-shot procedure, coupled with an advanced nozzle design, was used to drill (crater) deep holes into large material. With this procedure, a 600-lb block was reduced to smaller pieces without the use of any additional equipment. Through this advanced development program, the HIEE has demonstrated that it can quickly fragment salt cake material into small, easily removable fragments. The HIEE`s material fragmentation ability can be substantially increased through the use of different nozzle geometries and operating procedures.

  15. Improvement of auditing technology of safety analysis through thermal-hydraulic separate effect tests

    Energy Technology Data Exchange (ETDEWEB)

    No, Hee Cheon; Moon, Young Min; Lee, Dong Won; Lee, Sang Ik; Kim, Eung Soo; Yeom, Keum Soo [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    2002-03-15

    The objective of the present research is to perform the separate effect tests and to assess the RELAP5/MOD3.2 code for the analysis of thermal-hydraulic behavior in the reactor coolant system and the improvement of the auditing technology of safety analysis. Three Separate Effect Tests (SETs) are the reflux condensation in the U-tube, the direct contact condensation in the hot-leg and the mixture level buildup in the pressurizer. The experimental data and the empirical correlations are obtained through SETs. On the ases of the three SET works, models in RELAP5 are modified and improved, which are compared with the data. The Korea Standard Nuclear Power Plant (KSNP) are assessed using the modified RELAP5. In the reflux condensation test, the data of heat transfer coefficients and flooding are obtained and the condensation models are modified using the non-iterative model, as results, modified code better predicts the data. In the direct contact condensation test, the data of heat transfer coefficients are obtained for the cocurrent and countercurrent flow between the mixture gas and the water in condition of horizontal stratified flow. Several condensation and friction models are modified, which well predict the present data. In the mixture level test, the data for the mixture level and the onset of water draining into the surge line are obtained. The standard RELAP5 over-predicts the mixture level and the void fraction in the pressurizer. Simple modification of model related to the pool void fraction is suggested. The KSNP is assessed using the standard and the modified RELAP5 resulting from the experimental and code works for the SETs. In case of the pressurizer manway opening with available secondary side of the steam generators, the modified code predicts that the collapsed level in the pressurizer is little accumulated. The presence and location of the opening and the secondary condition of the steam generators have an effect on the coolant inventory. The

  16. IT-Tools Concept for Simulation and Design of Water Hydraulic Mechatronic Test Facilities for Motion Control and Operation in Environmentally Sensitive Application Areas

    DEFF Research Database (Denmark)

    Conrad, Finn; Pobedza, J.; Sobczyk, A.

    2004-01-01

    This paper presents a proposed IT-Tools concept for modeling, simulation, analysis and design of water hydraulic actuators for motion control of machines, lifts, cranes and robots. The designed test rigs have tap water hydraulic components of the Danfoss Nessie® product family and equipped...

  17. Comparison of the direct burst pressure and the ring tensile test methods for mechanical characterization of tissue-engineered vascular substitutes.

    Science.gov (United States)

    Laterreur, Véronique; Ruel, Jean; Auger, François A; Vallières, Karine; Tremblay, Catherine; Lacroix, Dan; Tondreau, Maxime; Bourget, Jean-Michel; Germain, Lucie

    2014-06-01

    Tissue engineering provides a promising alternative for small diameter vascular grafts, especially with the self-assembly method. It is crucial that these grafts possess mechanical properties that allow them to withstand physiological flow and pressure without being damaged. Therefore, an accurate assessment of their mechanical properties, especially the burst pressure, is essential prior to clinical release. In this study, the burst pressure of self-assembled tissue-engineered vascular substitutes was first measured by the direct method, which consists in pressurizing the construct with fluid until tissue failure. It was then compared to the burst pressure estimated by Laplace׳s law using data from a ring tensile test. The major advantage of this last method is that it requires a significantly smaller tissue sample. However, it has been reported as overestimating the burst pressure compared to a direct measurement. In the present report, it was found that an accurate estimation of the burst pressure may be obtained from a ring tensile test when failure internal diameter is used as the diameter parameter in Laplace׳s law. Overestimation occurs with the method previously reported, i.e. when the unloaded internal diameter is used for calculations. The estimation of other mechanical properties was also investigated. It was demonstrated that data from a ring tensile test provide an accurate estimate of the failure strain and the stiffness of the constructs when compared to measurements with the direct method. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. A maximum likelihood estimator for bedrock fracture transmissivities and its application to the analysis and design of borehole hydraulic tests

    Science.gov (United States)

    West, Anthony C. F.; Novakowski, Kent S.; Gazor, Saeed

    2006-06-01

    We propose a new method to estimate the transmissivities of bedrock fractures from transmissivities measured in intervals of fixed length along a borehole. We define the scale of a fracture set by the inverse of the density of the Poisson point process assumed to represent their locations along the borehole wall, and we assume a lognormal distribution for their transmissivities. The parameters of the latter distribution are estimated by maximizing the likelihood of a left-censored subset of the data where the degree of censorship depends on the scale of the considered fracture set. We applied the method to sets of interval transmissivities simulated by summing random fracture transmissivities drawn from a specified population. We found the estimated distributions compared well to the transmissivity distributions of similarly scaled subsets of the most transmissive fractures from among the specified population. Estimation accuracy was most sensitive to the variance in the transmissivities of the fracture population. Using the proposed method, we estimated the transmissivities of fractures at increasing scale from hydraulic test data collected at a fixed scale in Smithville, Ontario, Canada. This is an important advancement since the resultant curves of transmissivity parameters versus fracture set scale would only previously have been obtainable from hydraulic tests conducted with increasing test interval length and with degrading equipment precision. Finally, on the basis of the properties of the proposed method, we propose guidelines for the design of fixed interval length hydraulic testing programs that require minimal prior knowledge of the rock.

  19. Testing the interaction model with cosmological data and gamma-ray bursts

    CERN Document Server

    Pan, Yu; Gong, Yungui; Liao, Kai; Zhu, Zong-Hong

    2012-01-01

    We use the new gamma-ray bursts (GRBs) data, combined with the baryon acoustic oscillation(BAO) observation from the spectroscopic Sloan Digital Sky Survey (SDSS) data release, the newly obtained $A$ parameter at $z=0.6$ from the WiggleZ Dark Energy Survey, the cosmic microwave background (CMB) observations from the 7-Year Wilkinson Microwave Anisotropy Probe (WMAP7) results, and the type Ia supernovae (SNeIa) from Union2 set, to constrain a phenomenological model describing possible interactions between dark energy and dark matter, which was proposed to alleviate the coincidence problem of the standard $\\Lambda$CDM model. By using the Markov Chain Monte Carlo (MCMC) method, we obtain the marginalized $1\\sigma$ constraints $\\Omega_{m}=0.2886\\pm{0.0135}$, $r_m=-0.0047\\pm{0.0046}$, and $w_X=-1.0658\\pm{0.0564}$. We also consider other combinations of these data for comparison. These results show that: (1) the energy of dark matter is slightly transferring to that of dark energy; (2) even though the GRBs+BAO+CMB ...

  20. Testing Models for the Shallow Decay Phase of Gamma-Ray Burst Afterglows with Polarization Observations

    CERN Document Server

    Lan, Mi-Xiang; Dai, Zi-Gao

    2016-01-01

    The X-ray afterglows of almost one half of gamma-ray bursts (GRBs) have been discovered to have a shallow decay phase by the {\\em Swift} satellite, whose origin remains mysterious. Two main models have been proposed to explain this phase, relativistic wind bubbles (RWBs) and structured ejecta, which could originate from millisecond magnetars and rapidly-rotating black holes, respectively. Based on these models, we here investigate polarization evolution in the shallow decay phase of X-ray and optical afterglows. We find that in the RWB model, a significant bump of the polarization degree evolution curve appears during the shallow decay phase of both optical and X-ray afterglows, while the polarization position angle changes its direction by $90^\\circ$ abruptly. In the structured ejecta model, however, the polarization degree does not evolve significantly during the shallow decay phase of afterglows, no matter whether the magnetic field configuration in the ejecta is random or globally large-scale. Therefore, ...

  1. Hydraulic and thermal testing of different helium cooled irradiation rig models for the IFMIF High Flux Test Module

    Energy Technology Data Exchange (ETDEWEB)

    Klein, Christine, E-mail: Christine.Klein@kit.edu; Arbeiter, Frederik; Martin, Thomas; Taubmann, Peter

    2016-03-15

    Highlights: • Two different single 1:1 irradiation rigs inside a mock-up container are presented. • Pressure drops in the single rig minichannels are measured. • Temperature fields are measured under different heater and flow conditions. • Predictability and reproducibility of the cooling flows can be shown. - Abstract: The hydraulic and thermal testing of two different irradiation rig models A and B, differing in the inlet nozzle design, bottom reflector length and steps inside a mock-up container is part of the HFTM validation activities which support the engineering design of the High Flux Test Module. The pressure drops for all models in the test section are measured for overall mass flow rates of 1–12 g/s and different absolute pressures of 1500 hPa and 2500 hPa at the pressure port at the inlet section. The pressure drops in different sections of the experiment and in the single rig minichannels are also measured with additional pressure ports on the surfaces of the rig models. Predictability and reproducibility of the cooling effects of the main cooling channels in the HFTM irradiation zone can be shown. Rig model B with a backward facing step is for high mass flow rates >∼7.5 g/s (this is the operation regime of the HFTM) superior to rig model A. Uniform perfusion of the multiple parallel minichannels of the irradiation rigs by helium gas is of importance to obtain uniform and predictable temperatures. Temperature fields under different heater and flow conditions have been measured.

  2. Development of coupled neutronics/thermal–hydraulics test case for HPLWR

    Science.gov (United States)

    Pham, P.; Gamtsemlidze, I. D.; Bahdanovich, R. B.; Nikonov, S. P.; Smirnov, A. D.

    2017-01-01

    The High-Performance Light Water Reactor (HPLWR) is the European concept of a supercritical water reactor (SCWR) which is one of the most promising and innovative designs of the Generation IV nuclear reactor concepts. The thermal–hydraulics behavior of supercritical water is significantly different from water at sub-critical pressure because of the difference in the specific heat value. Coupled analysis of HPLWR assembly neutronics and thermal–hydraulics has become important because of the strong influence of the water density on the neutron spectrum and power distribution. Programs MCU (Monte-Carlo Universal) and ATHLET (Analysis of Thermal-hydraulics of Leaks and Transients) were used for better estimation of power and temperature distribution in HPLWR assembly.

  3. Multi-level slug tests in highly permeable formations: 2. Hydraulic conductivity identification, method verification, and field applications

    Science.gov (United States)

    Zlotnik, V.A.; McGuire, V.L.

    1998-01-01

    Using the developed theory and modified Springer-Gelhar (SG) model, an identification method is proposed for estimating hydraulic conductivity from multi-level slug tests. The computerized algorithm calculates hydraulic conductivity from both monotonic and oscillatory well responses obtained using a double-packer system. Field verification of the method was performed at a specially designed fully penetrating well of 0.1-m diameter with a 10-m screen in a sand and gravel alluvial aquifer (MSEA site, Shelton, Nebraska). During well installation, disturbed core samples were collected every 0.6 m using a split-spoon sampler. Vertical profiles of hydraulic conductivity were produced on the basis of grain-size analysis of the disturbed core samples. These results closely correlate with the vertical profile of horizontal hydraulic conductivity obtained by interpreting multi-level slug test responses using the modified SG model. The identification method was applied to interpret the response from 474 slug tests in 156 locations at the MSEA site. More than 60% of responses were oscillatory. The method produced a good match to experimental data for both oscillatory and monotonic responses using an automated curve matching procedure. The proposed method allowed us to drastically increase the efficiency of each well used for aquifer characterization and to process massive arrays of field data. Recommendations generalizing this experience to massive application of the proposed method are developed.Using the developed theory and modified Springer-Gelhar (SG) model, an identification method is proposed for estimating hydraulic conductivity from multi-level slug tests. The computerized algorithm calculates hydraulic conductivity from both monotonic and oscillatory well responses obtained using a double-packer system. Field verification of the method was performed at a specially designed fully penetrating well of 0.1-m diameter with a 10-m screen in a sand and gravel alluvial

  4. Fault degradation assessment of water hydraulic motor by impulse vibration signal with Wavelet Packet Analysis and Kolmogorov Smirnov Test

    Science.gov (United States)

    Chen, H. X.; Chua, Patrick S. K.; Lim, G. H.

    2008-10-01

    The machinery fault diagnosis is important for improving reliability and performance of systems. Many methods such as Time Synchronous Average (TSA), Fast Fourier Transform (FFT)-based spectrum analysis and short-time Fourier transform (STFT) have been applied in fault diagnosis and condition monitoring of mechanical system. The above methods analyze the signal in frequency domain with low resolution, which is not suitable for non-stationary vibration signal. The Kolmogorov-Smirnov (KS) test is a simple and precise technique in vibration signal analysis for machinery fault diagnosis. It has limited use and advantage to analyze the vibration signal with higher noise directly. In this paper, a new method for the fault degradation assessment of the water hydraulic motor is proposed based on Wavelet Packet Analysis (WPA) and KS test to analyze the impulsive energy of the vibration signal, which is used to detect the piston condition of water hydraulic motor. WPA is used to analyze the impulsive vibration signal from the casing of the water hydraulic motor to obtain the impulsive energy. The impulsive energy of the vibration signal can be obtained by the multi-decomposition based on Wavelet Packet Transform (WPT) and used as feature values to assess the fault degradation of the pistons. The kurtosis of the impulsive energy in the reconstructed signal from the Wavelet Packet coefficients is used to extract the feature values of the impulse energy by calculating the coefficients of the WPT multi-decomposition. The KS test is used to compare the kurtosis of the impulse energy of the vibration signal statistically under the different piston conditions. The results show the applicability and effectiveness of the proposed method to assess the fault degradation of the pistons in the water hydraulic motor.

  5. Test-retest reliability of handgrip strength measurement using a hydraulic hand dynamometer in patients with cervical radiculopathy.

    Science.gov (United States)

    Savva, Christos; Giakas, Giannis; Efstathiou, Michalis; Karagiannis, Christos

    2014-01-01

    The purpose of this study was to evaluate the test-retest reliability of handgrip strength measurement using a hydraulic hand dynamometer in patients with cervical radiculopathy (CR). A convenience sample of 19 participants (14 men and 5 women; mean ± SD age, 50.5 ± 12 years) with CR was measured using a Jamar hydraulic hand dynamometer by the same rater on 2 different testing sessions with an interval of 7 days between sessions. Data collection procedures followed standardized grip strength testing guidelines established by the American Society of Hand Therapists. During the repeated measures, patients were advised to rest their upper limb in the standardized arm position and encouraged to exert 3 maximum gripping efforts. The mean value of the 3 efforts (measured in kilogram force [Kgf]) was used for data analysis. The intraclass correlation coefficient, SEM, and the Bland-Altman plot were used to estimate test-retest reliability and measurement precision. Grip strength measurement in CR demonstrated an intraclass correlation coefficient of 0.976, suggesting excellent test-retest reliability. The small SEM in both testing sessions (SEM1, 2.41 Kgf; SEM2, 2.51 Kgf) as well as the narrow width of the 95% limits of agreements (95% limits of agreement, -4.9 to 4.4 Kgf) in the Bland-Altman plot reflected precise measurements of grip strength in both occasions. Excellent test-retest reliability for grip strength measurement was measured in patients with CR, demonstrating that a hydraulic hand dynamometer could be used as an outcome measure for these patients. Copyright © 2014 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  6. Thermomechanical Model and Bursting Tests to Evaluate the Risk of Swelling and Bursting of Modified 9Cr-1Mo Steel Steam Generator Tubes during a Sodium-Water Reaction Accident

    Directory of Open Access Journals (Sweden)

    C. Bertrand

    2014-01-01

    Full Text Available The MECTUB code was developed to evaluate the risk of swelling and bursting of Steam Generator (SG tubes. This code deals with the physic of intermediate steam-water leaks into sodium which induce a Sodium-Water Reaction (SWR. It is based on a one-dimensional calculation to describe the thermomechanical behavior of tubes under a high internal pressure and a fast external overheating. The mechanical model of MECTUB is strongly correlated with the kind of the material of the SG tubes. It has been developed and validated by using experiments performed on the alloy 800. A change to tubes made of Modified 9Cr-1Mo steel requires more knowledge of Modified 9Cr-1Mo steel behavior which influences the bursting time at high temperatures (up to 1200°C. Studies have been initiated to adapt the mechanical model and to qualify it for this material. The first part of this paper focuses on the mechanical law modelling (elasticity, plasticity, and creep for Modified 9Cr-1Mo steel and on overheating thermal data. In a second part, the results of bursting tests performed on Modified 9Cr-1Mo tubes in the SQUAT facility of CEA are used to validate the mechanical model of MECTUB for the Modified 9Cr-1Mo material.

  7. Improvement of auditing technology of safety analysis through thermal-hydraulic separate effect tests

    Energy Technology Data Exchange (ETDEWEB)

    No, Hee Cheon; Park, Hyun Sik; Kim, Hyoung Tae; Moon, Young Min; Choi, Sung Won; Hwang, Do Hyun [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    2000-03-15

    The direct-contact condensation hear transfer coefficients are experimentally obtained in the following conditions : pure steam/steam in the presence of noncondensible gas, horizontal/slightly inclined pipe, cocurrent/countercurrent stratified flow with water. The empirical correlation for liquid Nusselt number is developed in conditions of the slightly inclined pipe and the cocurrent stratified flow. The several models - the wall friction coefficient, the interfacial friction coefficient, the correlation of direct-contact condensation with noncondensible gases, and the correlation of wall film condensation - in the RELAP5/MOD3.2 code are modified, As results, RELAP5/MOD3.2 is improved. The present experimental data is used for evaluating the improved code. The standard RELAP5/MOD3.2 code is modified using the non-iterative modeling, which is a mechanistic model and does not require any interfacial information such as the interfacial temperature, The modified RELAP5/MOD3.2 code os used to simulate the horizontally stratified in-tube condensation experiment which represents the direct-contact condensation phenomena in a hot leg of a nuclear reactor. The modeling capabilities of the modified code as well as the standard code are assessed using several hot-leg condensation experiments. The modified code gives better prediction over local experimental data of liquid void fraction and interfacial heat transfer coefficient than the standard code. For the separate effect test of the thermal-hydraulic phenomena in the pressurizer, the scaling analysis is performed to obtain a similarity of the phenomena between the Korea Standard Nuclear Power Plant(KSNPP) and the present experimental facility. The diameters and lengths of the hot-leg, the surge line and the pressurizer are scaled down with the similitude of CCFL and velocity. The ratio of gas flow rate is 1/25. The experimental facility is composed of the air-water supply tank, the horizontal pipe, the surge line and the

  8. Analysis of Accelerometer Data from a Woven Inflatable Creep Burst Test

    Science.gov (United States)

    James, George H.; Grygier, Michael; Selig, Molly M.

    2015-01-01

    Accelerometers were used to montor an inflatable test article during a creep test to failure. The test article experienced impulse events that were classified based on the response of the sensors and their time-dependent manifestation. These impulse events required specialized techniques to process the structural dynamics data. However, certain phenomena were defined as worthy of additional study. An assessment of one phenomena (a frequency near 1000Hz) showed a time dependent frequency and an amplitude that increased significantly near the end of the test. Hence, these observations are expected to drive future understanding of and utility in inflatable space structures.

  9. Testing the homogeneity of the Universe using gamma-ray bursts

    Science.gov (United States)

    Li, Ming-Hua; Lin, Hai-Nan

    2015-10-01

    Aims: The discovery of a statistically significant clustering in the distribution of gamma-ray bursts (GRBs) has recently been reported. Given that the cluster has a characteristic size of 2000-3000 Mpc and a redshift between 1.6 ≤ z ≤ 2.1, it has been claimed that this structure is incompatible with the cosmological principle of homogeneity and isotropy of our Universe. In this paper, we study the homogeneity of the GRB distribution using a subsample of the Greiner GRB catalogue, which contains 314 objects with redshift 0 defined homogeneity scale. The homogeneity scale, RH, is defined as the comoving radius of the sphere inside which the number of GRBs N(proportional to r3 within 1%, or equivalently above which the correlation dimension of the sample D2 is within 1% of D2 = 3. Results: For a flat ΛCDM Universe, a best-fit power law, ξ(r) = (r/r0)- γ, with the correlation length r0 = 413.64 ± 135.40 h-1 Mpc and slope γ = 1.57 ± 0.63 (at 1σ confidence level) for the real-space correlation function ξ(r) is obtained. We obtain a homogeneous distribution of GRBs with correlation dimension above D2 = 2.97 on scales of r ≥ 8200 h-1 Mpc. For the Swift subsample of 244 GRBs, the correlation length and slope are r0 = 387.51 ± 132.75 h-1 Mpc and γ = 1.57 ± 0.65 (at 1σ confidence level). The corresponding scale for a homogeneous distribution of GRBs is r ≥ 7700 h-1 Mpc. For the 75 SHOALS GRBs, the results are are r0 = 288.13 ± 192.85 h-1 Mpc and γ = 1.27 ± 0.54 (at 1σ confidence level), with the homogeneity scale r ≥ 8300 h-1 Mpc. For the 113 SHOALS GRBs at 0 < z < 6.3, the results are r0 = 489.66 ± 260.90 h-1 Mpc and γ = 1.67 ± 1.07 (at 1σ confidence level), with the homogeneity scale r ≥ 8700 h-1 Mpc. Conclusions: The results help to alleviate the tension between the new discovery of the excess clustering of GRBs and the cosmological principle of large-scale homogeneity. It implies that very massive structures in the relatively local

  10. Development of a Test Apparatus for Measurement of Hydraulic Fluid Efficiency

    Institute of Scientific and Technical Information of China (English)

    Matt Jackson; Brian Koehler

    2011-01-01

    With increasing demand for nonrenewable resources,energy conservation is critical.Efficiency gains allow more work to be performed while maintaining or even decreasing the energy expended in the process.Reducing the energy consumed by a system results in favorable economic and environmental impact.An apparatus has been developed to measure hydraulic fluid efficiency in a stationary application.The system can be used to develop more efficient fluids,leading to increased work output or decreased energy consumption.

  11. Implementing ground surface deformation tools to characterize field-scale properties of a fractured aquifer during a short hydraulic test

    Science.gov (United States)

    Schuite, Jonathan; Longuevergne, Laurent; Bour, Olivier; Boudin, Frédérick; Durand, Stéphane

    2016-04-01

    In naturally fractured reservoirs, fluid flow is governed by the structural and hydromechanical properties of fracture networks or conductive fault zones. In order to ensure a sustained exploitation of resources or to assess the safety of underground storage, it is necessary to evaluate these properties. As they generally form highly heterogeneous and anisotropic reservoirs, fractured media may be well characterized by means of several complementary experimental methods or sounding techniques. In this framework, the observation of ground deformation has been proved useful to gain insight of a fractured reservoir's geometry and hydraulic properties. Commonly, large conductive structures like faults can be studied from surface deformation from satellite methods at monthly time scales, whereas meter scale fractures have to be examined under short-term in situ experiments using high accuracy intruments like tiltmeters or extensometers installed in boreholes or at the ground's surface. To the best of our knowledge, the feasability of a field scale (~ 100 m) characterization of a fractured reservoir with geodetic tools in a short term experiment has not yet been addressed. In the present study, we implement two complementary ground surface geodetic tools, namely tiltmetry and optical leveling, to monitor the deformation induced by a hydraulic recovery test at the Ploemeur hydrological observatory (France). Employing a simple purely elastic modeling approach, we show that the joint use of time constraining data (tilt) and spatially constraining data (vertical displacement) makes it possible to evaluate the geometry (dip, root depth and lateral extent) and the storativity of a hydraulically active fault zone, in good agreement with previous studies. Hence we demonstrate that the adequate use of two complementary ground surface deformation methods offer a rich insight of large conductive structure's properties using a single short term hydraulic load. Ground surface

  12. Highly Perturbed Operational Test Configurations at the WSMR Fast Burst Reactor

    Directory of Open Access Journals (Sweden)

    Flanders T. Michael

    2016-01-01

    Full Text Available The White Sands Missile Range (WSMR MoLLY-G reactor has a long history of producing a well characterized environment for testing electronic systems/devices in fission environments. As an unmoderated, unreflected, bare critical assembly, it provides a slightly degraded fission spectrum with a 1/E tail. For radiation hardness testing of electronics, the neutron fluence is usually reported as the 1-MeV Equivalent Neutron Fluence for Silicon. In this paper, we examine additional neutron environments and characterizations ranging from low intensity neutron fields to more extreme modifications of our normal test environment.

  13. Fracture hydraulic conductivity in the Mexico City clayey aquitard: Field piezometer rising-head tests

    Science.gov (United States)

    Vargas, Carlos; Ortega-Guerrero, Adrián

    A regional lacustrine aquitard covers the main aquifer of the metropolitan area of Mexico City. The aquitard's hydraulic conductivity (K') is fundamental for evaluating the natural protection of the aquifer against a variety of contaminants present on the surface and its hydraulic response. This study analyzes the distribution and variation of K' in the plains of Chalco, Texcoco and Mexico City (three of the six former lakes that existed in the Basin of Mexico), on the basis of 225 field-permeability tests, in nests of existing piezometers located at depths of 2-85 m. Tests were interpreted using the Hvorslev method and some by the Bouwer-Rice method. Results indicate that the distribution of K' fits log-Gaussian regression models. Dominant frequencies for K' in the Chalco and Texcoco plains range between 1E-09 and 1E-08 m/s, with similar population means of 1.19E-09 and 1.7E-09 m/s, respectively, which are one to two orders of magnitude higher than the matrix conductivity. In the Mexico City Plain the population mean is near by one order of magnitude lower; K'=2.6E-10 m/s. The contrast between the measured K' and that of the matrix is attributed to the presence of fractures in the upper 25-40 m, which is consistent with the findings of previous studies on solute migration in the aquitard. Un imperméable régional d'origine lacustre recouvre le principal aquifère de la zone urbaine de la ville de Mexico. La conductivité hydraulique K' de cet imperméable est fondamentale pour évaluer la protection naturelle de l'aquifère, contre les différents contaminants présents en surface, et sa réponse hydraulique. Cette étude analyse et les variations de K' dans les plaines de Chalco, Texcoco et Mexico (trois des six anciens lacs qui existaient dans le Bassin de Mexico), sur la base de 225 essais de perméabilité sur le terrain, réalisés en grappes dans des piézomètres existants entre 2 et 85 m de profondeur. Les essais ont été interprétés avec la m

  14. Experimental-based Modelling and Simulation of Water Hydraulic Mechatronics Test Facilities for Motion Control and Operation in Environmental Sensitive Applications` Areas

    DEFF Research Database (Denmark)

    Conrad, Finn; Pobedza, J.; Sobczyk, A.

    2003-01-01

    proportional valves and servo actuators for motion control and power transmission undertaken in co-operation by Technical University, DTU and Cracow University of Technology, CUT. The results of this research co-operation include engineering design and test of simulation models compared with two mechatronic......The paper presents experimental-based modelling, simulation, analysis and design of water hydraulic actuators for motion control of machines, lifts, cranes and robots. The contributions includes results from on-going research projects on fluid power and mechatronics based on tap water hydraulic...... test rig facilities powered by environmental friendly water hydraulic servo actuator system. Test rigs with measurement and data acquisition system were designed and build up with tap water hydraulic components of the Danfoss Nessie® product family. This paper presents selected experimental...

  15. Depth-discrete specific storage in fractured sedimentary rock using steady-state and transient single-hole hydraulic tests

    Science.gov (United States)

    Quinn, Patryk M.; Cherry, John A.; Parker, Beth L.

    2016-11-01

    A method is presented for obtaining depth-discrete values of specific storage (Ss) from single-hole hydraulic tests in fractured rock boreholes using straddle packers (1.5-17 m test intervals). Low flow constant head (CH) step tests analyzed using the Thiem method provide transmissivity (T) values free from non-Darcian error. Short-term, constant-rate pumping tests (0.5-2 h) analyzed using the Cooper-Jacob approximation of the Theis method provide S from the hydraulic diffusivity using the Darcian T value from the CH step test. This synergistic use of two types of hydraulic tests avoids the common source of error when pumping tests (injection or withdrawal) are conducted at higher flow rates and thereby induce non-Darcian flow resulting in the underestimation of T. Other errors, such as well bore storage and leakage, can also substantially influence S by causing a shift in the time axis of the Cooper-Jacob semi-log plot. In this approach, the Darcian T values from the CH step tests are used in the analysis of the transient pumping test data for calculating S throughout the pumping test using the Cooper-Jacob approximation to minimize all of the aforementioned errors, resulting in more representative S values. The effect of these non-idealities on the measured drawdown is illustrated using the Theis equation with the Darcian T and S values to calculate drawdown for comparison to measured data. The Ss values for tests in sandstone obtained from this approach are more consistent with confined aquifer conditions than values derived from the traditional Cooper-Jacob method, and are within the range of field and lab values presented from a compilation of literature values for fractured sandstone. (10-7-10-5 m-1) This method for obtaining Ss values from short-interval, straddle packer tests improves the estimation of both K and Ss and provides opportunity to study their spatial distribution in fractured rock.

  16. DEVELOPMENT OF A COMPUTER PROGRAM TO SUPPORT AN EFFICIENT NON-REGRESSION TEST OF A THERMAL-HYDRAULIC SYSTEM CODE

    Directory of Open Access Journals (Sweden)

    JUN YEOB LEE

    2014-10-01

    Full Text Available During the development process of a thermal-hydraulic system code, a non-regression test (NRT must be performed repeatedly in order to prevent software regression. The NRT process, however, is time-consuming and labor-intensive. Thus, automation of this process is an ideal solution. In this study, we have developed a program to support an efficient NRT for the SPACE code and demonstrated its usability. This results in a high degree of efficiency for code development. The program was developed using the Visual Basic for Applications and designed so that it can be easily customized for the NRT of other computer codes.

  17. Research on Power Recycling Test Method of Integrative Hydraulic Pump and Motor%联体泵马达功率回收试验方法研究

    Institute of Scientific and Technical Information of China (English)

    郭刘洋; 刘俊; 唐守生; 郭杨浏

    2013-01-01

    The experimental method for the integrative hydraulic pump and motor was researched. The power recycling theory of hydraulic pump was analyzed. According to character of the integrative hydraulic pump and motor,the test method for the integrative hydraulic pump and motor power recycling was defined. The formula to calculate volumetric efficiency was deduced. The power recycling test result is assist to analyze volumetric efficiency,meanwhile,to verify the fundamental performance of the integrative hydraulic pump and motor. Additionally,the test result proves that the integrative hydraulic pump and motor power recycling test method is feasible.%  针对联体泵马达的试验方法进行研究,分析液压泵的功率回收试验原理,根据联体泵马达的结构特点,确定了联体泵马达功率回收试验方法,并推导出容积效率计算公式;通过功率回收试验,对联体泵马达的容积效率进行了测试,验证了泵马达的基本性能,也证实了功率回收方法的有效性和可行性。

  18. Numerical Modeling of a Thermal-Hydraulic Loop and Test Section Design for Heat Transfer Studies in Supercritical Fluids

    Science.gov (United States)

    McGuire, Daniel

    A numerical tool for the simulation of the thermal dynamics of pipe networks with heat transfer has been developed with the novel capability of modeling supercritical fluids. The tool was developed to support the design and deployment of two thermal-hydraulic loops at Carleton University for the purpose of heat transfer studies in supercritical and near-critical fluids. First, the system was characterized based on its defining features; the characteristic length of the flow path is orders of magnitude larger than the other characteristic lengths that define the system's geometry; the behaviour of the working fluid in the supercritical thermodynamic state. An analysis of the transient thermal behaviour of the model's domains is then performed to determine the accuracy and range of validity of the modeling approach for simulating the transient thermal behaviour of a thermal-hydraulic loop. Preliminary designs of three test section geometries, for the purpose of heat transfer studies, are presented in support of the overall design of the Carleton supercritical thermal-hydraulic loops. A 7-rod-bundle, annular and tubular geometries are developed with support from the new numerical tool. Materials capable of meeting the experimental requirements while operating in supercritical water are determined. The necessary geometries to satisfy the experimental goals are then developed based on the material characteristics and predicted heat transfer behaviour from previous simulation results. An initial safety analysis is performed on the test section designs, where they are evaluated against the ASME Boiler, Pressure Vessel, and Pressure Piping Code standard, required for safe operation and certification.

  19. Development and qualification of a thermal-hydraulic nodalization for modeling station blackout accident in PSB-VVER test facility

    Energy Technology Data Exchange (ETDEWEB)

    Saghafi, Mahdi [Department of Energy Engineering, Sharif University of Technology, Azadi Avenue, Tehran (Iran, Islamic Republic of); Ghofrani, Mohammad Bagher, E-mail: ghofrani@sharif.edu [Department of Energy Engineering, Sharif University of Technology, Azadi Avenue, Tehran (Iran, Islamic Republic of); D’Auria, Francesco [San Piero a Grado Nuclear Research Group (GRNSPG), University of Pisa, Via Livornese 1291, San Piero a Grado, Pisa (Italy)

    2016-07-15

    Highlights: • A thermal-hydraulic nodalization for PSB-VVER test facility has been developed. • Station blackout accident is modeled with the developed nodalization in MELCOR code. • The developed nodalization is qualified at both steady state and transient levels. • MELCOR predictions are qualitatively and quantitatively in acceptable range. • Fast Fourier Transform Base Method is used to quantify accuracy of code predictions. - Abstract: This paper deals with the development of a qualified thermal-hydraulic nodalization for modeling Station Black-Out (SBO) accident in PSB-VVER Integral Test Facility (ITF). This study has been performed in the framework of a research project, aiming to develop an appropriate accident management support tool for Bushehr nuclear power plant. In this regard, a nodalization has been developed for thermal-hydraulic modeling of the PSB-VVER ITF by MELCOR integrated code. The nodalization is qualitatively and quantitatively qualified at both steady-state and transient levels. The accuracy of the MELCOR predictions is quantified in the transient level using the Fast Fourier Transform Base Method (FFTBM). FFTBM provides an integral representation for quantification of the code accuracy in the frequency domain. It was observed that MELCOR predictions are qualitatively and quantitatively in the acceptable range. In addition, the influence of different nodalizations on MELCOR predictions was evaluated and quantified using FFTBM by developing 8 sensitivity cases with different numbers of control volumes and heat structures in the core region and steam generator U-tubes. The most appropriate case, which provided results with minimum deviations from the experimental data, was then considered as the qualified nodalization for analysis of SBO accident in the PSB-VVER ITF. This qualified nodalization can be used for modeling of VVER-1000 nuclear power plants when performing SBO accident analysis by MELCOR code.

  20. Evaluation of Demo 1C composite flywheel rotor burst test and containment design

    Energy Technology Data Exchange (ETDEWEB)

    Kass, M.D.; McKeever, J.W.; Akerman, M.A.; Goranson, P.L.; Litherland, P.S.; O`Kain, D.U.

    1998-07-01

    Laboratory-Directed funds were provided in FY 1995 for research to develop flywheel containment specifications and to consider concepts that could satisfy these specifications and produce a prototype small, lightweight, inexpensive, mobile flywheel containment. Research activities have included an analytical and pictorial review of the Demo 1C flywheel failure test, which provided significant insight about radial and axial failure modes; calculations of the thickness of ultra-conservative pressure vessel containment; entertainment of advanced containment concepts using lightweight materials and armor literature; consideration of fabrication assembly procedures; and participation in a Flywheel Energy Storage Workshop during which additional flywheel failure experiences were discussed. Based on these activities, calculations, and results, a list of conclusions concerning flywheel containment and its relation to the flywheel are presented followed by recommendations for further research.

  1. Modelling, Testing and Analysis of a Regenerative Hydraulic Shock Absorber System

    Directory of Open Access Journals (Sweden)

    Ruichen Wang

    2016-05-01

    Full Text Available To improve vehicle fuel economy whilst enhancing road handling and ride comfort, power generating suspension systems have recently attracted increased attention in automotive engineering. This paper presents our study of a regenerative hydraulic shock absorber system which converts the oscillatory motion of a vehicle suspension into unidirectional rotary motion of a generator. Firstly a model which takes into account the influences of the dynamics of hydraulic flow, rotational motion and power regeneration is developed. Thereafter the model parameters of fluid bulk modulus, motor efficiencies, viscous friction torque, and voltage and torque constant coefficients are determined based on modelling and experimental studies of a prototype system. The model is then validated under different input excitations and load resistances, obtaining results which show good agreement between prediction and measurement. In particular, the system using piston-rod dimensions of 50–30 mm achieves recoverable power of 260 W with an efficiency of around 40% under sinusoidal excitation of 1 Hz frequency and 25 mm amplitude when the accumulator capacity is set to 0.32 L with the load resistance 20 Ω. It is then shown that the appropriate damping characteristics required from a shock absorber in a heavy-haulage vehicle can be met by using variable load resistances and accumulator capacities in a device akin to the prototype. The validated model paves the way for further system optimisation towards maximising the performance of regeneration, ride comfort and handling.

  2. 液压泵性能测试实验台设计%Design of Performance Test Bench for Hydraulic Pump

    Institute of Scientific and Technical Information of China (English)

    郑明辉; 江吉彬; 郭熛

    2011-01-01

    Hydraulic pump as hydraulic system's power part, is one of important parts of engineering machinery product. The hydraulic pump performance test bench is the necessary device for hydraulic pump product quality examination which is the main safe guard of pump product quality. A hydraulic pump performance test bench was designed. The composition, working principle and char acteristics of the hydraulic system were introduced. Data test and analysis were carried on.%液压泵作为液压系统的动力元件,是工程机械产品的重要部件之一.液压泵性能测试实验台是进行液压泵产品质量检测的必要设备,是泵产品质量监控的主要保障.设计了液压泵性能测试实验台,介绍液压系统组成、工作原理和特点,并进行了数据测试及分析.

  3. ORNL rod-bundle heat-transfer test data. Volume 6. Thermal-hydraulic test facility experimental data report for test 3. 05. 5B - double-ended cold-leg break simulation

    Energy Technology Data Exchange (ETDEWEB)

    Mullins, C.B.; Felde, D.K.; Sutton, A.G.; Gould, S.S.; Morris, D.G.; Robinson, J.J.; Schwinkendorf, K.N.

    1982-05-18

    Thermal-Hydraulic Test Facility (THTF) Test 3.05.5B was conducted by members of the ORNL PWR Blowdown Heat Transfer Separate-Effects Program on July 3, 1980. The objective of the program is to investigate heat transfer phenomena believed to occur in PWRs during accidents, including small and large break loss-of-coolant accidents. Test 3.05.5B was designed to provide transient thermal-hydraulics data in rod bundle geometry under reactor accident-type conditions. Reduced instrument responses are presented. Also included are uncertainties in the instrument responses, calculated mass flows, and calculated rod powers.

  4. Core thermal hydraulic behavior during the reflood phase of cold-leg LBLOCA experiments using the ATLAS test facility

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Seok; Park, Hyun Sik; Choi, Ki Yong; Kang, Kyoung Ho; Baek, Won Pil; Kim, Yeon Sik [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2009-12-15

    Several experimental tests to simulate a reflood phase of a cold-leg LBLOCA of the APR1400 have been performed using the ATLAS facility. This paper describes the related experimental results with respect to the thermal-hydraulic behavior in the core and the system-core interactions during the reflood phase of the cold-leg LBLOCA conditions. The present descriptions will be focused on the LB-CL-09, LB-CL-11, LB-CL-14, and LB-CL-15 tests performed using the ATLAS. The LB-CL-09 is an integral effect test with conservative boundary condition; the LB-CL-11 and -14 are integral effect tests with realistic boundary conditions, and the LB-CL-15 is a separated effect test. The objectives of these tests are to investigate the thermal-hydraulic behavior during an entire reflood phase and to provide reliable experimental data for validating the LBLOCA analysis methodology for the APR1400. The initial and boundary conditions were obtained by applying scaling ratios to the MARS simulation results for the LBLOCA scenario of the APR1400. The ECC water flow rate from the safety injection tanks and the decay heat were simulated from the start of the reflood phase. The simulated core power was controlled to be 1.2 times that of the ANS-73 decay heat curve for LB-CL-09 and 1.02 times that of the ANS-79 decay curve for LB-CL-11, -14, and -15. The simulated ECC water flow rate from the high pressure safety injection pump was 0.32 kg/s. The present experimental data showed that the cladding temperature behavior is closely related to the collapsed water level in the core and the downcomer

  5. Characteristics and performance analysis report of the major thermal hydraulic components in the high temperature/high pressure thermal hydraulic test facility (VISTA)

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ki Yong; Park, Hyun Sik; Cho, Seok; Lee, Sung Jae; Song, Chul Hwa; Park, Chun Kyong; Chung, Moon Ki

    2003-12-01

    The VISTA (Experimental Verification by Integral Simulation of Transients and Accidents) is an experimental facility to verify the performance and safety issues of the SMART-P (Pilot plant of the System-integrated Modular Advanced Reactor). The basic design of the SMART-P has been completed by KAERI. The present report describes the characteristics and performance of the major thermal hydraulic components in the VISTA Facility.

  6. An Analytical Solution of Hydraulic Head due to an Oscillatory Pumping Test in a Confined, Unconfined or Leaky Aquifer

    Science.gov (United States)

    Huang, C. S.; Yeh, H. D.

    2014-12-01

    This study builds a mathematical model for three-dimensional (3D) transient hydraulic head induced by an oscillatory pumping test in a confined, unconfined or leaky aquifer. The aquifers are of a rectangular shape where the four sides are under the Robin conditions. The 3D flow governing equation with a line sink term representing a vertical well is employed. The sink term has a cosine function for the oscillatory pumping. A general equation describing the head on the top of the three kinds of aquifers is considered. The analytical head solution of the model is derived by the direct Fourier method and the double-integral transform and in terms of a double series with fast convergence. With the aid of the solution, we have found that the vertical component of flow vanishes when Kv d2/(KhD2) > 1 where Kh and Kv are aquifer's hydraulic conductivities, respectively, D is aquifer's thickness, and d is a distance measured from the pumping well. Under the condition, temporal head distributions predicted by the present solution agree with those predicted by solutions developed based on two-dimensional flow by most previous researches.

  7. Predictive permeability model of faults in crystalline rocks; verification by joint hydraulic factor (JH) obtained from water pressure tests

    Science.gov (United States)

    Barani, Hamidreza Rostami; Lashkaripour, Gholamreza; Ghafoori, Mohammad

    2014-08-01

    In the present study, a new model is proposed to predict the permeability per fracture in the fault zones by a new parameter named joint hydraulic factor (JH). JH is obtained from Water Pressure Test (WPT) and modified by the degree of fracturing. The results of JH correspond with quantitative fault zone descriptions, qualitative fracture, and fault rock properties. In this respect, a case study was done based on the data collected from Seyahoo dam site located in the east of Iran to provide the permeability prediction model of fault zone structures. Datasets including scan-lines, drill cores, and water pressure tests in the terrain of Andesite and Basalt rocks were used to analyse the variability of in-site relative permeability of a range from fault zones to host rocks. The rock mass joint permeability quality, therefore, is defined by the JH. JH data analysis showed that the background sub-zone had commonly core had permeability characteristics nearly as low as the outer damage zone, represented by 8 Lu (1.3 ×10-4 m 3/s) per fracture, with occasional peaks towards 12 Lu (2 ×10-4 m 3/s) per fracture. The maximum JH value belongs to the inner damage zone, marginal to the fault core, with 14-22 Lu (2.3 ×10-4-3.6 ×10-4 m 3/s) per fracture, locally exceeding 25 Lu (4.1 ×10-4 m 3/s) per fracture. This gives a proportional relationship for JH approximately 1:4:2 between the fault core, inner damage zone, and outer damage zone of extensional fault zones in crystalline rocks. The results of the verification exercise revealed that the new approach would be efficient and that the JH parameter is a reliable scale for the fracture permeability change. It can be concluded that using short duration hydraulic tests (WPTs) and fracture frequency (FF) to calculate the JH parameter provides a possibility to describe a complex situation and compare, discuss, and weigh the hydraulic quality to make predictions as to the permeability models and permeation amounts of different

  8. Predictive permeability model of faults in crystalline rocks; verification by joint hydraulic factor (JH) obtained from water pressure tests

    Indian Academy of Sciences (India)

    Hamidreza Rostami Barani; Gholamreza Lashkaripour; Mohammad Ghafoori

    2014-08-01

    In the present study, a new model is proposed to predict the permeability per fracture in the fault zones by a new parameter named joint hydraulic factor (JH). JH is obtained from Water Pressure Test WPT) and modified by the degree of fracturing. The results of JH correspond with quantitative fault zone descriptions, qualitative fracture, and fault rock properties. In this respect, a case study was done based on the data collected from Seyahoo dam site located in the east of Iran to provide the permeability prediction model of fault zone structures. Datasets including scan-lines, drill cores, and water pressure tests in the terrain of Andesite and Basalt rocks were used to analyse the variability of in-site relative permeability of a range from fault zones to host rocks. The rock mass joint permeability quality, therefore, is defined by the JH. JH data analysis showed that the background sub-zone had commonly > 3 Lu (less of 5 × 10−5 m3/s) per fracture, whereas the fault core had permeability characteristics nearly as low as the outer damage zone, represented by 8 Lu (1.3 × 10−4 m3/s) per fracture, with occasional peaks towards 12 Lu (2 × 10−4 m3/s) per fracture. The maximum JH value belongs to the inner damage zone, marginal to the fault core, with 14–22 Lu (2.3 × 10−4 –3.6 × 10−4 m3/s) per fracture, locally exceeding 25 Lu (4.1 × 10−4 m3/s) per fracture. This gives a proportional relationship for JH approximately 1:4:2 between the fault core, inner damage zone, and outer damage zone of extensional fault zones in crystalline rocks. The results of the verification exercise revealed that the new approach would be efficient and that the JH parameter is a reliable scale for the fracture permeability change. It can be concluded that using short duration hydraulic tests (WPTs) and fracture frequency (FF) to calculate the JH parameter provides a possibility to describe a complex situation and compare, discuss, and weigh the hydraulic quality to make

  9. Hydraulic characterization of volcanic rocks in Pahute Mesa using an integrated analysis of 16 multiple-well aquifer tests, Nevada National Security Site, 2009–14

    Science.gov (United States)

    Garcia, C. Amanda; Jackson, Tracie R.; Halford, Keith J.; Sweetkind, Donald S.; Damar, Nancy A.; Fenelon, Joseph M.; Reiner, Steven R.

    2017-01-20

    An improved understanding of groundwater flow and radionuclide migration downgradient from underground nuclear-testing areas at Pahute Mesa, Nevada National Security Site, requires accurate subsurface hydraulic characterization. To improve conceptual models of flow and transport in the complex hydrogeologic system beneath Pahute Mesa, the U.S. Geological Survey characterized bulk hydraulic properties of volcanic rocks using an integrated analysis of 16 multiple-well aquifer tests. Single-well aquifer-test analyses provided transmissivity estimates at pumped wells. Transmissivity estimates ranged from less than 1 to about 100,000 square feet per day in Pahute Mesa and the vicinity. Drawdown from multiple-well aquifer testing was estimated and distinguished from natural fluctuations in more than 200 pumping and observation wells using analytical water-level models. Drawdown was detected at distances greater than 3 miles from pumping wells and propagated across hydrostratigraphic units and major structures, indicating that neither faults nor structural blocks noticeably impede or divert groundwater flow in the study area.Consistent hydraulic properties were estimated by simultaneously interpreting drawdown from the 16 multiple-well aquifer tests with an integrated groundwater-flow model composed of 11 well-site models—1 for each aquifer test site. Hydraulic properties were distributed across volcanic rocks with the Phase II Pahute Mesa-Oasis Valley Hydrostratigraphic Framework Model. Estimated hydraulic-conductivity distributions spanned more than two orders of magnitude in hydrostratigraphic units. Overlapping hydraulic conductivity ranges among units indicated that most Phase II Hydrostratigraphic Framework Model units were not hydraulically distinct. Simulated total transmissivity ranged from 1,600 to 68,000 square feet per day for all pumping wells analyzed. High-transmissivity zones exceeding 10,000 square feet per day exist near caldera margins and extend

  10. 液压比例控制系统在液压支架用安全阀试验台上的应用%Application of Hydraulic Proportional Control System in Hydraulic Safety Valve Test Table

    Institute of Scientific and Technical Information of China (English)

    马强

    2013-01-01

    针对原液压支架用安全阀试验台流量调节过程繁琐、效率及检测精度低的问题,采用比例控制技术,进行闭环流量控制.改进了试验台的液压系统,实现了流量调节的自动化,提高了试验效率及检测精度.%There are problems existing in the original hydraulic safety valve test bench,including complicated flow controlling process and low accuracy and detection efficiency.To solve the problems,the proportional control technology was used to realize closed-loop flow control.The hydraulic system of the experiment platform was improved.The automation of flow regulation is realized,and the test efficiency and accuracy are improved.

  11. Hydraulic structures

    CERN Document Server

    Chen, Sheng-Hong

    2015-01-01

    This book discusses in detail the planning, design, construction and management of hydraulic structures, covering dams, spillways, tunnels, cut slopes, sluices, water intake and measuring works, ship locks and lifts, as well as fish ways. Particular attention is paid to considerations concerning the environment, hydrology, geology and materials etc. in the planning and design of hydraulic projects. It also considers the type selection, profile configuration, stress/stability calibration and engineering countermeasures, flood releasing arrangements and scouring protection, operation and maintenance etc. for a variety of specific hydraulic structures. The book is primarily intended for engineers, undergraduate and graduate students in the field of civil and hydraulic engineering who are faced with the challenges of extending our understanding of hydraulic structures ranging from traditional to groundbreaking, as well as designing, constructing and managing safe, durable hydraulic structures that are economical ...

  12. Estimation of hydraulic parameters from an unconfined aquifer test conducted in a glacial outwash deposit, Cape Cod, Massachusetts

    Science.gov (United States)

    Moench, A.F.; Garabedian, Stephen P.; LeBlanc, Denis R.

    2000-01-01

    An aquifer test conducted in a sand and gravel, glacial outwash deposit on Cape Cod, Massachusetts was analyzed by means of a model for flow to a partially penetrating well in a homogeneous, anisotropic unconfined aquifer. The model is designed to account for all significant mechanisms expected to influence drawdown in observation piezometers and in the pumped well. In addition to the usual fluid-flow and storage processes, additional processes include effects of storage in the pumped well, storage in observation piezometers, effects of skin at the pumped-well screen, and effects of drainage from the zone above the water table. The aquifer was pumped at a rate of 320 gallons per minute for 72-hours and drawdown measurements were made in the pumped well and in 20 piezometers located at various distances from the pumped well and depths below the land surface. To facilitate the analysis, an automatic parameter estimation algorithm was used to obtain relevant unconfined aquifer parameters, including the saturated thickness and a set of empirical parameters that relate to gradual drainage from the unsaturated zone. Drainage from the unsaturated zone is treated in this paper as a finite series of exponential terms, each of which contains one empirical parameter that is to be determined. It was necessary to account for effects of gradual drainage from the unsaturated zone to obtain satisfactory agreement between measured and simulated drawdown, particularly in piezometers located near the water table. The commonly used assumption of instantaneous drainage from the unsaturated zone gives rise to large discrepancies between measured and predicted drawdown in the intermediate-time range and can result in inaccurate estimates of aquifer parameters when automatic parameter estimation procedures are used. The values of the estimated hydraulic parameters are consistent with estimates from prior studies and from what is known about the aquifer at the site. Effects of

  13. HYDRAULIC SERVO

    Science.gov (United States)

    Wiegand, D.E.

    1962-05-01

    A hydraulic servo is designed in which a small pressure difference produced at two orifices by an electrically operated flapper arm in a constantly flowing hydraulic loop is hydraulically amplified by two constant flow pumps, two additional orifices, and three unconnected ball pistons. Two of the pistons are of one size and operate against the additional orifices, and the third piston is of a different size and operates between and against the first two pistons. (AEC)

  14. 3-D Hydraulic Model Testing of the New Roundhead in Suape, Brazil

    DEFF Research Database (Denmark)

    Andersen, Thomas Lykke; Burcharth, Hans F.; Sipavicius, A.;

    This report deals with a three-dimensional model test study of the extension of the breakwater in Suape, Brazil. The roundhead was tested for stability in various sea conditions. The length scale used for the model tests was 1:35. Unless otherwise specified all values given in this report are pro...

  15. Integral and Separate Effects Tests for Thermal Hydraulics Code Validation for Liquid-Salt Cooled Nuclear Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, Per

    2012-10-30

    The objective of the 3-year project was to collect integral effects test (IET) data to validate the RELAP5-3D code and other thermal hydraulics codes for use in predicting the transient thermal hydraulics response of liquid salt cooled reactor systems, including integral transient response for forced and natural circulation operation. The reference system for the project is a modular, 900-MWth Pebble Bed Advanced High Temperature Reactor (PB-AHTR), a specific type of Fluoride salt-cooled High temperature Reactor (FHR). Two experimental facilities were developed for thermal-hydraulic integral effects tests (IETs) and separate effects tests (SETs). The facilities use simulant fluids for the liquid fluoride salts, with very little distortion to the heat transfer and fluid dynamics behavior. The CIET Test Bay facility was designed, built, and operated. IET data for steady state and transient natural circulation was collected. SET data for convective heat transfer in pebble beds and straight channel geometries was collected. The facility continues to be operational and will be used for future experiments, and for component development. The CIET 2 facility is larger in scope, and its construction and operation has a longer timeline than the duration of this grant. The design for the CIET 2 facility has drawn heavily on the experience and data collected on the CIET Test Bay, and it was completed in parallel with operation of the CIET Test Bay. CIET 2 will demonstrate start-up and shut-down transients and control logic, in addition to LOFC and LOHS transients, and buoyant shut down rod operation during transients. Design of the CIET 2 Facility is complete, and engineering drawings have been submitted to an external vendor for outsourced quality controlled construction. CIET 2 construction and operation continue under another NEUP grant. IET data from both CIET facilities is to be used for validation of system codes used for FHR modeling, such as RELAP5-3D. A set of

  16. The Design of Hydraulic Circuit of Hydraulic Steering Gear for Teaching Test-bed%液压舵机教学实验台液压系统的设计

    Institute of Scientific and Technical Information of China (English)

    卢运娇

    2014-01-01

    为了满足教学和相关科研的需要,笔者所在的教学团队设计了一套液压舵机教学实验台,针对实验台中的液压控制部分进行设计,并介绍其工作原理。该系统具有结构简单,造价成本低,运行安全可靠等优点,无论是在教学上还是科研试验中都将起到积极的作用。%The teaching team designed a set of hydraulic steering gear test-bed for teaching and scientific research.Hydraulic circuit is designed for the test-bed and its working principle is introduced .The hydraulic circuit has the advantages of simple structure, low cost, safe and reliable operation and so on.The design for teaching or for related research will play an active role.

  17. Proof test on thermal and hydraulic design reliability of Japanese PWR fuel assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Akiyama, Mamoru (Univ. of Tokyo (Japan)); Inoue, Akira (Tokyo Institute of Technology (Japan)); Miyazaki, Keiji (Osaka Univ. (Japan)); Abeta, Sadaaki (Mitsubishi, Tokyo (Japan)); Hori, Keiichi (Mitsubishi, Hyogo (Japan)); Mukasa, Tomio; Oishi, Masao; Aoki, Toshimasa; Makihara, Yoshiaki

    1990-01-01

    A series of departure from nucleate boiling (DNB) tests for pressurized water reactors (PWRs) was performed at the Nuclear Power Engineering Test Center. The objective was to prove the reliability of fuel assembly design by confirming the thermal margin of heat transfer. The present method for evaluating the DNB ratio in a Japanese 17 x 17 PWR core is adequate according to the newly obtained DNB test data.

  18. Results of Hydraulic Tests in Miocene Tuffaceous Rocks at the C-Hole Complex, 1995 to 1997, Yucca Mountain, Nye County, Nevada

    Science.gov (United States)

    Geldon, Arthur L.; Umari, Amjad M.A.; Fahy, Michael F.; Earle, John D.; Gemmell, James M.; Darnell, Jon

    2002-01-01

    Four hydraulic tests were conducted by the U.S. Geological Survey at the C-hole complex at Yucca Mountain, Nevada, between May 1995 and November 1997. These tests were conducted as part of ongoing investigations to determine the hydrologic and geologic suitability of Yucca Mountain as a potential site for permanent underground storage of high-level nuclear waste. The C-hole complex consists of three 900-meter-deep boreholes that are 30.4 to 76.6 meters apart. The C-holes are completed in fractured, variably welded tuffaceous rocks of Miocene age. Six hydrogeologic intervals occur within the saturated zone in these boreholes - the Calico Hills, Prow Pass, Upper Bullfrog, Lower Bullfrog, Upper Tram, and Lower Tram intervals. The Lower Bullfrog and Upper Tram intervals contributed about 90 percent of the flow during hydraulic tests. The four hydraulic tests conducted from 1995 to 1997 lasted 4 to 553 days. Discharge from the pumping well, UE-25 c #3, ranged from 8.49 to 22.5 liters per second in different tests. Two to seven observation wells, 30 to 3,526 meters from the pumping well, were used in different tests. Observation wells included UE-25 c #1, UE-25 c #2, UE-25 ONC-1, USW H-4, UE-25 WT #14, and UE-25 WT #3 in the tuffaceous rocks and UE-25 p #1 in Paleozoic carbonate rocks. In all hydraulic tests, drawdown in the pumping well was rapid and large (2.9-11 meters). Attributable mostly to frictional head loss and borehole-skin effects, this drawdown could not be used to analyze hydraulic properties. Drawdown and recovery in intervals of UE-25 c #1 and UE-25 c #2 and in other observation wells typically was less than 51 centimeters. These data were analyzed. Hydrogeologic intervals in the C-holes have layered heterogeneity related to faults and fracture zones. Transmissivity, hydraulic conductivity, and storativity generally increase downhole. Transmissivity ranges from 4 to 1,600 meters squared per day; hydraulic conductivity ranges from 0.1 to 50 meters per day

  19. Investigation of creep by use of closed loop servo-hydraulic test system

    Science.gov (United States)

    Wu, H. C.; Yao, J. C.

    1981-01-01

    Creep tests were conducted by means of a closed loop servo-controlled materials test system. These tests are different from the conventional creep tests in that the strain history prior to creep may be carefully monitored. Tests were performed for aluminum alloy 6061-0 at 150 C and monitored by a PDP 11/04 minicomputer at a preset constant plastic-strain rate prehistory. The results show that the plastic-strain rate prior to creep plays a significant role in creep behavior. The endochronic theory of viscoplasticity was applied to describe the observed creep curves. The concepts of intrinsic time and strain rate sensitivity function are employed and modified according to the present observation.

  20. Theoretical Analysis and Bench Tests of a Control-Surface Booster Employing a Variable Displacement Hydraulic Pump

    Science.gov (United States)

    Mathews, Charles W.; Kleckner, Harold F.

    1947-01-01

    The NACA is conducting a general investigation of servo-mechanisms for use in powering aircraft control surfaces. This paper presents a theoretical analysis and the results of bench tests of a control-booster system which employs a variable displacement hydraulic pump. The booster is intended for use in a flight investigation to determine the effects of various booster parameters on the handling qualities of airplanes. Such a flight investigation would aid in formulating specific requirements concerning the design of control boosters in general. Results of the theoretical analysis and the bench tests indicate that the subject booster is representative of types which show promise of satisfactory performance. The bench tests showed that the following desirable features were inherent in this booster system: (1) No lost motion or play in any part of the system; (2) no detectable lag between motion of the contra1 stick and control surface; and (3) Good agreement between control displacements and stick-force variations with no hysteresis in the stick-force characteristics. The final design configuration of this booster system showed no tendency to oscillate, overshoot, or have other undesirable transient characteristics common to boosters.

  1. Pre-test analysis of an integral effect test facility for thermal hydraulic similarities of 6 inches cold leg break and DVI line break using MARS-1D

    Energy Technology Data Exchange (ETDEWEB)

    Ah, D. J.; Park, H. S.; Choi, K. Y.; Kwon, T. S.; Baek, W. P. [KAERI, Taejon (Korea, Republic of)

    2002-05-01

    Pre-test analyses of a small-break loss-of-coolant accident (SBLOCA) and a DVI line break accident, have been performed for the integral effect test loop of Korea Atomic Energy Research Institute (KAERI-ITL), the construction of which will be started soon. The KAERI-ITL is being designed with a full-height and 1/310 volume scale based on the design features of the APR1400 (Korean Next Generation Reactor). Based on the same control logics and accident scenarios, the similarity between the KAERI-ITL and the prototype plant, APR1400, is evaluated using the MARS code. It is found that the KAERI-ITL and APR1400 have similar thermal hydraulic responses during the transient under the identical accident scenarios. It is also verified that the volume scaling law, applied to the design of the KAERI-ITL, gives reasonable results to keep the similarity between APR1400 and KAERI-ITL.

  2. Experimental-based Modelling and Simulation of Water Hydraulic Mechatronics Test Facilities for Motion Control and Operation in Environmental Sensitive Applications` Areas

    DEFF Research Database (Denmark)

    Conrad, Finn; Pobedza, J.; Sobczyk, A.

    2003-01-01

    The paper presents experimental-based modelling, simulation, analysis and design of water hydraulic actuators for motion control of machines, lifts, cranes and robots. The contributions includes results from on-going research projects on fluid power and mechatronics based on tap water hydraulic...... proportional valves and servo actuators for motion control and power transmission undertaken in co-operation by Technical University, DTU and Cracow University of Technology, CUT. The results of this research co-operation include engineering design and test of simulation models compared with two mechatronic...

  3. Integrating fluorescent dye flow-curve testing and acoustic Doppler velocimetry profiling for in situ hydraulic evaluation and improvement of clarifier performance.

    Science.gov (United States)

    Tarud, F; Aybar, M; Pizarro, G; Cienfuegos, R; Pastén, P

    2010-08-01

    Enhancing the performance of clarifiers requires a thorough understanding of their hydraulics. Fluorescence spectroscopy and acoustic doppler velocimeter (ADV) profiling generally have been used separately to evaluate secondary settlers. We propose that simultaneous use of these techniques is needed to obtain a more reliable and useful evaluation. Experiments were performed on laboratory- and full-scale clarifiers. Factors affecting Fluorescein and Rhodamine 6G properties were identified. Underestimations up to 500% in fluorescence intensities may be derived from differential fluorescence quenching by oxygen. A careful control and interpretation of fluorescent dye experiments is needed to minimize artifacts in real settings. While flow-curve tests constructed under controlled conditions provided a more accurate overall quantitative estimation of the hydraulic performance, ADV velocity and turbulence profiling provided a detailed spatial understanding of flow patterns that was used to troubleshoot and fix the causes of hydraulic short-circuits.

  4. Application of SVP-A Hydraulic Support Strength Test Simulation System%SVP-A液压支架强度试验仿真系统的应用

    Institute of Scientific and Technical Information of China (English)

    王雅

    2014-01-01

    文章详细介绍了SVP-A液压支架强度试验仿真系统的实体模型及应用状况,分析了液压支架结构的应力分布特点,得出该系统具有较好的实用性和可普及性,是进行液压支架研究设计的有效工具。%This paper introduces the application of strength of SVP-A hydraulic support test simulation system, analysis of the structure characteristic of hydraulic support's stress distribution, the author concluded that the system has good practicability and universality, it is also a powerful tool for the study of hydraulic support design.

  5. Assembly and Thermal Hydraulic Test of a Stainless Steel Sodium-Potassium Circuit

    Science.gov (United States)

    Garber, A.; Godfroy, T.; Webster, K.

    2007-01-01

    Early Flight Fission Test Facilities (EFF-TF) team has been tasked by the NASA Marshall Space Flight Center Nuclear Systems Office to design, fabricate, and test an actively pumped alkali metal flow circuit. The system was originally built for use with lithium, but due to a shift in focus, it was redesigned for use with a eutectic mixture of sodium potassium (NaK). Basic circuit components include: reactor segment, NaK to gas heat exchanger, electromagnetic (EM) liquid metal pump, load/drain reservoir, expansion reservoir, instrumentation, and a spill reservoir. A 37-pin partial-array core (pin and flow path dimensions are the same as those in a full design) was selected for fabrication and test. This paper summarizes the first fill and checkout testing of the Stainless Steel NaK-Cooled Circuit (SNaKC).

  6. Validation of the APROS thermal-hydraulics against the PACTEL test facility

    Energy Technology Data Exchange (ETDEWEB)

    Plit, H.R.; Porkholm, K. [IVO Power Engineering Ltd., Vantaa (Finland); Maenninen, M.

    1997-12-31

    APROS - Advanced PROcess Simulator - has been developed since 1986 together with the Technical Research Centre of Finland (VTT) and IVO Power Engineering Ltd (IVO PE) for process and automation design, safety analysis and training simulator applications. Up to now the APROS development has required more than 150 man years. APROS applications include nuclear and fossil power plant models, but also chemical as well as pulp and paper processes can be modeled. PACTEL - PArallel Channel TEst Loop - is an experimental integral test facility for VVER-440 nuclear power plants. VVER nuclear power plants have some special features like hexagonal fuel assemblies and horizontal steam generators. Therefore PACTEL experiments provide for VVER-purposes unique information which can not be obtained with normal PWR integral test facilities. PACTEL experiments are also very important for computer codes, like APROS, for VVER validation. (author)

  7. A methodology for the analysis of a thermal-hydraulic phenomenon investigated in a test facility

    Energy Technology Data Exchange (ETDEWEB)

    D`Auria, F. [Dept. of Mechanical and Nuclear Constructions, Pisa Univ. (Italy); Faluomi, V. [Dept. of Mechanical and Nuclear Constructions, Pisa Univ. (Italy); Aksan, N. [Lab. for Thermal-Hydraulics, Paul Scherrer Inst., Villigen (Switzerland)

    1995-08-01

    A methodology for analysing non-homogeneous sets of experimental data for a selected phenomenon from separate effect test facilities and integral test facilities is presented in this paper. The critical heat flux from the validation matrices was chosen as the phenomenon to be studied; the results obtained in three test facilities are analysed. The method presented is applied for estimating the accuracy with which a thermalhydraulic transient code can predict the critical heat flux in an actual nuclear power plant. (orig.) [Deutsch] Gegenstand des Beitrags ist ein Verfahren zur Analyse ungleichartiger Datensaetze, die bei der experimentellen Untersuchung eines bestimmten thermohydraulischen Phaenomens in speziellen oder integralen Testeinrichtungen gewonnen wurden. Bei dem untersuchten Phaenomen handelt es sich hier um die kritische Waermestromdichte; experimentelle Daten aus drei Testeinrichtungen werden analysiert. Das Verfahren wird benutzt, um die Genauigkeit abzuschaetzen, mit der ein thermohydraulischer Rechencode zur Beschreibung von Uebergangszustaenden die kritische Waermestromdichte in einem Kernkraftwerk vorhersagen kann. (orig.)

  8. Thermal hydraulic performance analysis of the printed circuit heat exchanger using a helium test facility and CFD simulations

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In Hun [Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, 373-1, Guseong-dong, Yuseong-gu, Daejeon 305-701 (Korea, Republic of); No, Hee Cheon [Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, 373-1, Guseong-dong, Yuseong-gu, Daejeon 305-701 (Korea, Republic of)], E-mail: hcno@kaist.ac.kr; Lee, Jeong Ik; Jeon, Byong Guk [Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, 373-1, Guseong-dong, Yuseong-gu, Daejeon 305-701 (Korea, Republic of)

    2009-11-15

    The thermal-hydraulic performance of the PCHE was investigated using the KAIST helium test loop. Experiments were performed in the helium laminar region with 350 < Re < 1200. The hot/cold side inlet conditions were 25-550 {sup o}C/25-100 {sup o}C over the operating pressure of 1.5-1.9 MPa, respectively. Mass flow rates were controlled in the range of 40-100 kg/h. Pressure drop and temperature difference were measured at the inlet and outlet of the hot and cold sides. A global Fanning factor correlation and a global Nusselt number correlation were proposed using information only at the inlet and outlet of the hot and cold sides. A three-dimensional (3-D) numerical simulation was performed using FLUENT, a commercial computational fluid dynamics (CFD) code, to compare simulation results to the KAIST helium test data and to obtain the local Nusselt number in the PCHE. CFD predictions showed good agreement with experimental data. A local pitch-averaged Nusselt number correlation was proposed using local temperature, pressure, surface heat fluxes, and properties provided by CFD simulations. The system analysis code, GAMMA, was also utilized to identify which correlation was more applicable for system analysis. It turns out that the proposed local pitch-averaged Nusselt number correlation from CFD simulations is more appropriate than the global Nusselt number correlation developed from experimental data.

  9. Predicting the occurrence of mixed mode failure associated with hydraulic fracturing, part 2 water saturated tests

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, Stephen J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Broome, Scott Thomas [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Choens, Charles [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Barrow, Perry Carl [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-09-14

    Seven water-saturated triaxial extension experiments were conducted on four sedimentary rocks. This experimental condition was hypothesized more representative of that existing for downhole hydrofracture and thus it may improve our understanding of the phenomena. In all tests the pore pressure was 10 MPa and confirming pressure was adjusted to achieve tensile and transitional failure mode conditions. Using previous work in this LDRD for comparison, the law of effective stress is demonstrated in extension using this sample geometry. In three of the four lithologies, no apparent chemo-mechanical effect of water is apparent, and in the fourth lithology test results indicate some chemo-mechanical effect of water.

  10. Experimental studies on dynamic system characteristics of the high temperature/high pressure thermal-hydraulic test facility(VISTA) for the power variation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, K. Y.; Park, H. S.; Joe, S.; Park, C. K.; Lee, S. J.; Song, C. W.; Jeong, M. K. [KAERI, Taejon (Korea, Republic of)

    2003-10-01

    Dynamic system characteristics tests were carried out for the power variation by using the high temperature/high pressure thermal-hydraulic test facility, VISTA(Experimental Verification by Integral Simulation of Transient and Accidents), which had been constructed to simulate the SMART-P by KAERI. Experimental tests have been performed to investigate the thermal-hydraulic dynamic characteristics of the primary and the secondary systems in the range of 5% to 85% power. Automatic PID control logics were developed and installed to the VISTA facility to control the major thermal hydraulic parameters. Power was changed with either a step or a ramp changing method from the reference power of 10%, 25%, 50% and 75% to 5% or 10% higher power. It was found that there is no noticeable difference in the responses between a step and a ramp changing method. When unique constants of P, I, and D were used in the range of 5% to 85% power, it was found to be liable to lose the system control. Further studies are required to quantify the controllability and the time constants of the major thermal hydraulic parameters.

  11. Testing of molded high temperature plastic actuator road seals for use in advanced aircraft hydraulic systems

    Science.gov (United States)

    Waterman, A. W.; Huxford, R. L.; Nelson, W. G.

    1976-01-01

    Molded high temperature plastic first and second stage rod seal elements were evaluated in seal assemblies to determine performance characteristics. These characteristics were compared with the performance of machined seal elements. The 6.35 cm second stage Chevron seal assembly was tested using molded Chevrons fabricated from five molding materials. Impulse screening tests conducted over a range of 311 K to 478 K revealed thermal setting deficiencies in the aromatic polyimide molding materials. Seal elements fabricated from aromatic copolyester materials structurally failed during impulse cycle calibration. Endurance testing of 3.85 million cycles at 450 K using MIL-H-83283 fluid showed poorer seal performance with the unfilled aromatic polyimide material than had been attained with seals machined from Vespel SP-21 material. The 6.35 cm first stage step-cut compression loaded seal ring fabricated from copolyester injection molding material failed structurally during impulse cycle calibration. Molding of complex shape rod seals was shown to be a potentially controllable technique, but additional molding material property testing is recommended.

  12. A study of return to saturation oscillations in the OSU APEX thermal hydraulic testing facility

    Science.gov (United States)

    Franz, Scott Cameron

    The purpose of this paper is to describe the flow oscillations which occur in the AP600 long term cooling test facility at Oregon State University. The AP600 system is an advanced pressurized water reactor design utilizing passive emergency cooling systems. A few hours after the initiation of a cold leg break, the passive cooling systems inject gravity fed cold water at a rate allowing steam production in the reactor vessel. Steam production in the core causes the pressure in the upper head to increase leading to flow oscillations in all the connecting reactor systems. This paper will show that the oscillations have a definite region of onset and termination for specific conditions in the APEX testing facility. Tests performed at high powers, high elevation breaks, and small break sizes do not exhibit oscillations. The APOS (Advanced Plant Oscillation Simulator) computer code has been developed using a quasi-steady state analysis for flows and a transient analysis for the core node energy balance. The pressure in the reactor head is calculated using a modified perfect gas analysis. For tank liquid inventories, a simple conservation of mass analysis is used to estimate the tank elevations. Simulation logic gleaned from APEX data and photographic evidence have been incorporated into the code to predict termination of the oscillations. Areas which would make the work more complete include a better understanding of two-phase fluid behavior for a top offtake on a pipe, more instrumentation in the core region of the APEX testing facility, and a clearer understanding of fluid conditions in the reactor barrel. Scaling of the oscillations onset and pressure amplitude are relatively straightforward, but termination and period are difficult to scale to the full AP600 plant. Differences in the core power profile and other geometrical differences between the testing facility and the actual plant make the scaling of this phenomenon to the actual plant conditions very difficult.

  13. Mass Transfer And Hydraulic Testing Of The V-05 And V-10 Contactors With The Next Generation Solvent

    Energy Technology Data Exchange (ETDEWEB)

    Herman, D. T.; Duignan, M. R.; Williams, M. R.; Peters, T. B.; Poirier, M. R.; Fondeur, F. F.

    2013-07-31

    The Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU) facility is actively pursuing the transition from the current BOBCalixC6 based solvent to the Next Generation Solvent (NGS)-MCU solvent. To support this integration of NGS into the MCU facilities, Savannah River Remediation (SRR) requested that Savannah River National Laboratory (SRNL) perform testing of a blend of the NGS (MaxCalix based solvent) with the current solvent (BOBCalixC6 based solvent) for the removal of cesium (Cs) from the liquid salt waste stream. This testing differs from prior testing by utilizing a blend of BOBCalixC6 based solvent and the NGS with the full (0.05 M) concentration of the MaxCalix as well as a new suppressor, tris(3,7dimethyloctyl) guanidine. Single stage tests were conducted using the full size V-05 and V-10 centrifugal contactors installed at SRNL. These tests were designed to determine the mass transfer and hydraulic characteristics with the NGS solvent blended with the projected heel of the BOBCalixC6 based solvent that will exist in MCU at time of transition. The test program evaluated the amount of organic carryover and the droplet size of the organic carryover phases using several analytical methods. Stage efficiency and mass distribution ratios were determined by measuring Cs concentration in the aqueous and organic phases during single contactor testing. The nominal cesium distribution ratio, D(Cs) measured for extraction ranged from 37-60. The data showed greater than 96% stage efficiency for extraction. No significant differences were noted for operations at 4, 8 or 12 gpm aqueous salt simulant feed flow rates. The first scrub test (contact with weak caustic solution) yielded average scrub D(Cs) values of 3.3 to 5.2 and the second scrub test produced an average value of 1.8 to 2.3. For stripping behavior, the “first stage” D Cs) values ranged from 0.04 to 0.08. The efficiency of the low flow (0.27 gpm aqueous) was calculated to be 82.7%. The Spreadsheet

  14. Basic hydraulics

    CERN Document Server

    Smith, P D

    1982-01-01

    BASIC Hydraulics aims to help students both to become proficient in the BASIC programming language by actually using the language in an important field of engineering and to use computing as a means of mastering the subject of hydraulics. The book begins with a summary of the technique of computing in BASIC together with comments and listing of the main commands and statements. Subsequent chapters introduce the fundamental concepts and appropriate governing equations. Topics covered include principles of fluid mechanics; flow in pipes, pipe networks and open channels; hydraulic machinery;

  15. Analysis of hydraulic tests of the Culebra and Magenta Dolomites and Dewey Lake Redbeds conducted at the Waste Isolation Pilot Plant Site

    Energy Technology Data Exchange (ETDEWEB)

    Beauheim, R.L. [Sandia National Labs., Albuquerque, NM (United States). Geohydrology Dept.; Ruskauff, G.J. [Duke Engineering and Services, Inc., Albuquerque, NM (United States)

    1998-09-01

    This report presents interpretations of hydraulic tests conducted at 15 well locations in the vicinity of the Waste Isolation Pilot Plant (WIPP) in southeastern New Mexico between 1980 and 1996. The WIPP is a US Department of Energy (DOE) facility to demonstrate safe disposal of transuranic wastes arising form the nation`s defense programs. The WIPP repository lies within bedded halite of the Salado Formation, 2,155 ft below ground surface. The tests reported herein were, with two exceptions, conducted in the Culebra Dolomite member of the Rustler Formation, which overlies the Salado Formation. The remaining tests were conducted in the Magenta Member of the Rustler and in the overlying formation, the Dewey Lake Redbeds. This report completes the documentation of hydraulic-test interpretations used as input to the WIPP Compliance Certification Application (US DOE, 1996).

  16. Hydraulic manipulator research at ORNL

    Energy Technology Data Exchange (ETDEWEB)

    Kress, R.L.; Jansen, J.F. [Oak Ridge National Lab., TN (United States); Love, L.J. [Oak Ridge Inst. for Science and Education, TN (United States)

    1997-03-01

    Recently, task requirements have dictated that manipulator payload capacity increase to accommodate greater payloads, greater manipulator length, and larger environmental interaction forces. General tasks such as waste storage tank cleanup and facility dismantlement and decommissioning require manipulator life capacities in the range of hundreds of pounds rather than tens of pounds. To meet the increased payload capacities demanded by present-day tasks, manipulator designers have turned once again to hydraulics as a means of actuation. In order to successfully design, build, and deploy a new hydraulic manipulator (or subsystem), sophisticated modeling, analysis, and control experiments are usually needed. Oak Ridge National Laboratory (ORNL) has a history of projects that incorporate hydraulics technology, including mobile robots, teleoperated manipulators, and full-scale construction equipment. In addition, to support the development and deployment of new hydraulic manipulators, ORNL has outfitted a significant experimental laboratory and has developed the software capability for research into hydraulic manipulators, hydraulic actuators, hydraulic systems, modeling of hydraulic systems, and hydraulic controls. The purpose of this article is to describe the past hydraulic manipulator developments and current hydraulic manipulator research capabilities at ORNL. Included are example experimental results from ORNL`s flexible/prismatic test stand.

  17. Water Hydraulic Systems

    DEFF Research Database (Denmark)

    Conrad, Finn

    2005-01-01

    The paper presents research results using IT-Tools for CAD and dynamic modelling, simulation, analysis, and design of water hydraulic actuators for motion control of machines, lifts, cranes and robots. Matlab/Simulink and CATIA are used as IT-Tools. The contributions include results from on......-going research projects on fluid power and mechatronics based on tap water hydraulic servovalves and linear servo actuators and rotary vane actuators for motion control and power transmission. Development and design a novel water hydraulic rotary vane actuator for robot manipulators. Proposed mathematical...... modelling, control and simulation of a water hydraulic rotary vane actuator applied to power and control a two-links manipulator and evaluate performance. The results include engineering design and test of the proposed simulation models compared with IHA Tampere University’s presentation of research...

  18. Mechanical and Hydraulic Characterization Tests of a Mid Grid for X-Gen Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyung Kyu; Lee, Kang Hee; Lee, Young Ho; Kim, Jae Yong; Yoon, Kyung Ho

    2008-09-15

    The Korea Nuclear Fuel Co. requested the high frequency flow-induced vibration and pressure drop, and the high temperature and high pressure fretting wear tests of mid grid candidates of X-Gen fuel. The following results were obtained for each test. - High frequency flow-induced vibration and pressure drop test Maximum vibration amplitudes of the two candidates (Y-10, T-20) were 570 mil/s and 1260 mil/s at the flowrate of 18 ft/s and 19 ft/s, respectively. Those of the other types (PLUS7 and modified PLUS7) were 1360 mil/s and 410 mil/s at the flowrate of 14 ft/s and 18 ft/s, respectively. The frequency characteristics showed a uniform increase from 1500 to 4500 Hz following the increase of the flow velocity, and a jump of the peak frequency at a specific velocity. Variation of the vane angle did not affect the frequency characteristic during the flow velocity change (cf. Y-10, T-20), while the characteristic varied considerably when the strap height was varied (cf. PLUS7 and its modified version). Average relative errors of the pressure drop[DP1, DP2] with respect to the PLUS7 were [-2.29 %, -2.0 %], [3.62 %, 4.82 %], [-1.61 %, -2.64 %] for X-Gen no.1, X-Gen no.2 and modified PLUS7 in order. Relative difference in the pressure drop showed an irregular tendency. A sensitivity of the pressure drop due to the variation of the strap height and vane angle was verified. - High temperature and high pressure fretting wear test Canoe-Y10 spring showed the most severe wear. An impact/sliding wear mechanism as well as the circular trace of the fuel rod motion were attributed to this result. The impact/sliding wear mechanism was confirmed from the wear scar observation. An actual wearing process was investigated by analysing the displacement signal obtained from the lower displacement sensors at the contacts.

  19. Estimating hydraulic conductivity of fractured rocks from high‐pressure packer tests with an Izbash's law‐based empirical model

    National Research Council Canada - National Science Library

    Chen, Yi‐Feng; Hu, Shao‐Hua; Hu, Ran; Zhou, Chuang‐Bing

    2015-01-01

    ...‐pressure groundwater flow conditions. The interpretation of the HPPT data, however, remains difficult due to the transition of flow conditions in the conducting structures and the hydraulic fracturing...

  20. The Hydraulic Test Report for Non-instrumented Irradiation Test Rig of DUO-Cooled Annular Pellet

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Ho; Lee, Kang Hee; Shin, Chang Hwan; Yang, Yong Sik; Kim, Sun Ki; Bang, Je Geon; Song, Kun Woo

    2007-08-15

    This report presents the results of pressure drop test and vibration test for non-instrumented rig of Advanced PWR DUO-Fuel Annular Pellet which were designed and fabricated by KAERI. From the pressure drop test results, it is noted that the flow velocity across the non-instrumented rig of Advanced PWR DUO-Fuel Annular Pellet corresponding to the pressure drop of 200 kPa is measured to be about 8.30 kg/sec. Vibration frequency results for the non-instrumented rig at the pump spin frequency ranges from 19.0 to 32.0 Hz, RMS(Root Mean Square) displacement for the non-instrumented rig of Advanced PWR DUO-Fuel Annular Pellet is less than 7.25 m, and the maximum displacement is less than 31.27 {mu}m. This test was performed at the FIVPET facility.

  1. 液压CAT系统测试误差分析%Error Analysis of the Hydraulic CAT System Test

    Institute of Scientific and Technical Information of China (English)

    胡森; 胡晓波

    2011-01-01

    本文对液压CAT技术的发展现状和趋势进行了探讨,并对液压元件CAT系统误差来源进行了分析,介绍一些液压CAT系统误差处理办法.%The development status and trends of hydraulic CAT technology are discussed, and the error sources of hydraulic component CAT system were analyzed, and some approaches are introduced in this paper.

  2. On the hydraulic behaviour of ITER Shield Blocks #14 and #08. Computational analysis and comparison with experimental tests

    Energy Technology Data Exchange (ETDEWEB)

    Di Maio, P.A. [Dipartimento di Energia, Ingegneria dell’Informazione e Modelli Matematici, Università di Palermo Viale delle Scienze, 90128, Palermo (Italy); Merola, M.; Mitteau, R.; Raffray, R. [ITER Organization, Route de Vinon sur Verdon, 13067 Saint Paul, Lez Durance (France); Vallone, E., E-mail: eug.vallone@gmail.com [Dipartimento di Energia, Ingegneria dell’Informazione e Modelli Matematici, Università di Palermo Viale delle Scienze, 90128, Palermo (Italy)

    2016-11-01

    Highlights: • A benchmarking activity has been carried out focusing the attention on the cooling circuits of ITER Shield Blocks #08 and #14. • A theoretical-computational fluid-dynamic approach based on the Finite Volume Method has been followed, adopting a commercial code. • Hydraulic characteristic functions and spatial distributions of coolant mass flow rate, velocity and pressure drop have been assessed. • Results obtained have allowed code benchmarking for Blanket modules and the numerical predictions have been found to be generally lower than but quite close to the experimental results (lower than 10%). - Abstract: As a consequence of its position and functions, the ITER blanket system will be subjected to significant heat loads under nominal reference conditions. Therefore, the design of its cooling system is particularly demanding. Coolant water is distributed individually to the 440 blanket modules (BMs) through manifold piping, which makes it a highly parallelized system. The mass flow rate distribution is finely tuned to meet all operation constraints: adequate margin to burn out in the plasma facing components, even distribution of water flow among the so-called plasma-facing “fingers” of the Blanket First Wall panels, high enough water flow rate to avoid excessive water temperature in the outlet pipes, maximum allowable water velocity lower than 7 m/s in manifold pipes. Furthermore the overall pressure drop and flow rate in each BM shall be within the fixed specified design limit to avoid an unduly unbalance of cooling among the 440 modules. Analyses have to be carried out following a computational fluid-dynamic (CFD) approach based on the finite volume method and adopting a CFD commercial code to assess the thermal-hydraulic behaviour of each single circuit of the ITER blanket cooling system. This paper describes the code benchmarking needed to determine the best method to get reliable and timely results. Since experimental tests are

  3. Hydraulic Structures

    Data.gov (United States)

    Department of Homeland Security — This table is required whenever hydraulic structures are shown in the flood profile. It is also required if levees are shown on the FIRM, channels containing the...

  4. Improvement of auditing technology of safety analysis through thermal-hydraulic separate effect tests

    Energy Technology Data Exchange (ETDEWEB)

    No, Hee Cheon; Park, Hyun Sik; Kim, Hyougn Tae; Moon, Young Min; Choi, Sung Won; Heo, Sun [Korea Advanced Institute Science and Technology, Taejon (Korea, Republic of)

    1999-04-15

    The loss-of-RHR accident during midloop operation has been important as results of the probabilistic safety analysis. The condensation models In RELAP5/MOD3 are not proper to analyze the midloop operation. To audit and improve the model in RELAP5/MOD3.2, several items of separate effect tests have been performed. The 29 sets of reflux condensation data is obtained and the correlation is developed with these heat transfer coefficient's data. In the experiment of the direct contact condensation in hot leg, the apparatus setting is finished and a few experimental data is obtained. Non-iterative model is used to predict the model in RELAP5/MOD3.2 with the results of reflux condensation and evaluates better than the present model. The results of the direct contact condensation in a hot leg represent to be similar with the present model. The study of the CCF and liquid entrainment in a surge line and pressurizer is selected as the third separate experiment and is on performance.

  5. Application of RELAP5/MOD3.3 to Calculate Thermal Hydraulic Behavior of the Pressurizer Safety Valve Performance Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Hyun; Kim, Young Ae; Oh, Seung Jong; Park, Jong Woon [Korea Hydro and Nuclear Power Co., Ltd., Daejeon (Korea, Republic of)

    2007-10-15

    The increase of the acceptance tolerance of Pressurizer Safety Valve (PSV) test is vital for the safe operation of nuclear power plants because the frequent tests may make the valves decrepit and become a cause of leak. Recently, Korea Hydro and Nuclear Power Company (KHNP) is building a PSV performance test facility to provide the technical background data for the relaxation of the acceptance tolerance of PSV including the valve pop-up characteristics and the loop seal dynamics (if the plant has the loop seal in the upstream of PSV). The discharge piping and supports must be designed to withstand severe transient hydrodynamic loads when the safety valve actuates. The evaluation of hydrodynamic loads is a two-step process: first the thermal hydraulic behavior in the piping must be defined, and then the hydrodynamic loads are calculated from the thermal hydraulic parameters such as pressure and mass flow. The hydrodynamic loads are used as input to the structural analysis.

  6. Testing a DBI model for the unification of dark matter and dark energy with Gamma-Ray Bursts

    CERN Document Server

    Montiel, Ariadna

    2012-01-01

    We study the range of consistency of a model based on a nonlinear scalar field Dirac-Born-Infeld action for the unification of dark matter and dark energy using Gamma-Ray Bursts at high-redshifts. We use the sample of 59 high-redshift GRBs reported by Wei (2010), calibrated at low redshifts with the Union 2 sample of SNe Ia, thus avoiding the circularity problem. In this analysis, we also include the CMB7-year data and the baryonic acoustic peak BAO. Besides, it is calculated the parameter of the equation of state $w$, the deceleration parameter $q_0$ and the redshift of the transition to the decelerate-accelerated phase $z_t$.

  7. Geological and hydrogeological conditions of the Aigion seismic active fault zone (Deep Geodynamic Laboratory Corinth) based on borehole data and hydraulic tests

    Science.gov (United States)

    Rettenmaier, D.; Giurgea, V.; Pizzino, L.; Unkel, I.; Hoetzl, H.; Foerster, A.; Quattrocchi, F.; Nikas, K.

    2003-04-01

    The Gulf of Corinth and the northern part of the Peloponnesus/Greece, an area of asymmetric graben structure, step faults and tilted blocks, is one of the most active seismic zones in the world. Six major faults are known to be most responsible for the historic and present seismic activities in the area of Aigion. Our study focuses preliminarily on the area around the Aigion fault, whose trace runs E-W through the harbour of Aigion. Investigations of the stratigraphic sequence, tectonic structure and hydrogeologic conditions of the southern Corinth graben shoulder and first drilling activities there, have started in summer 2001. From July until September 2002 the International Continental Deep Drilling Project (ICDP) and the EU Project DGLab-Gulf of Corinth drilled the AIG10 borehole in the harbour of Aigion to a total depth of 1001 m. Our investigations in this ICDP/EU framework are aimed at studying the thermal-hydraulic conditions on the southern graben shoulder. Here we report the first results on sampling and hydraulic testing. The deep AIG10 borehole has successfully cored in approx. 760 m depth the fault plane, which separates fractured radiolarite in the hanging wall from highly fractured and karstified platy, micritic limestone (Olonos-Pindos Unit) in the footwall. A complete lithologic section is now available through the monitoring of cuttings and cores, which built a major cornerstone for defining an integrated regional tectonic and geologic model. Several pumping tests and hydrochemical investigations made in the region of Aigion and especially in the AIG10 borehole deliver together with geophysical borehole logging the database for a thermo-hydraulic heat flow model. The pumping test AIG10C in the conglomerates of the graben sediments show a hydraulic conductivity of about 2 x 10E-5 m/s - 3 x 10E-4 m/s at a depth of approximately 211 m. The result was a residual drawdown, which indicates a closed hydraulic system between the semi-permeable Aigion

  8. Small-Scale Water Ingression and Crust Strength Tests (SSWICS) SSWICS-6 test data report : thermal hydraulic results, Rev. 0.

    Energy Technology Data Exchange (ETDEWEB)

    Lomperski, S.; Farmer, M. T.; Kilsdonk, D.; Aeschlimann, B. (Nuclear Engineering Division)

    2011-06-28

    The Melt Attack and Coolability Experiments (MACE) program at Argonne National Laboratory addressed the issue of the ability of water to cool and thermally stabilize a molten core/concrete interaction (MCCI) when the reactants are flooded from above. These tests provided data regarding the nature of corium interactions with concrete, the heat transfer rates from the melt to the overlying water pool, and the role of noncondensable gases in the mixing processes that contribute to melt quenching. However, due to the integral nature of these tests, several questions regarding the crust freezing behavior could not be adequately resolved. These questions include: (1) To what extent does water ingression into the crust increase the melt quench rate above the conduction-limited rate and how is this affected by melt composition and system pressure? (2) What is the fracture strength of the corium crust when subjected to a thermal-mechanical load and how does it depend upon the melt composition? A series of separate-effects experiments are being conducted to address these issues. The first employs an apparatus designed to measure the quench rate of a pool of corium ({approx} {phi} 30 cm; up to 20 cm deep). The main parameter to be varied in these quench tests is the melt composition since it is thought to have a critical influence on the crust cracking behavior which, in turn, alters quench rate. The issue of crust strength is being addressed with a second apparatus designed to mechanically load the crust produced by the quench tests. This apparatus measures the fracture strength of the crust while it is either at room temperature or above, the latter state being achieved with a heating element placed below the crust. The two apparatuses used to measure the melt quench rate and crust strength are jointly referred to as SSWICS (Small-Scale Water Ingression and Crust Strength). This report describes results of the sixth water ingression test, designated SSWICS-6. This test

  9. Preliminary experimental results using the thermal-hydraulic integral test facility (VISTA) for the pilot plant of the system integrated modular advanced reactor, SMART-P

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ki Yong; Pak, Hyun Sik; Cho, Seok; Pak, Choon Kyung; Lee, Sung Jae; Song, Chul Hwa; Chung, Moon Ki [KAERI, Taejon (Korea, Republic of)

    2003-07-01

    Preliminary experimental tests were carried out using the thermal-hydraulic integral test facility, VISTA (Experimental Verification by Integral Simulation of Transients and Accidents), which has been constructed to simulate the SMART-P. The VISTA facility is an integral test facility including the primary and secondary systems as well as safety-related Passive Residual heat removal (PRHR) systems. Its scaled ratio with respect to the SMART-P is 1/1 in height and 1/96 in volume and heater power. So far, several steady states and transient tests have been carried out to verify the overall thermal hydraulic primary and secondary characteristics in a range of 10% to 100% power operation. As results of preliminary results, the steady state conditions were found to coincide with the expected design values of the SMART-P. But the major thermal hydraulic parameters are greatly affected by the initial water level and the nitrogen pressure in the reactor upper annular cavity. In the PRHR transient tests, the steam inlet temperature of the PRHR system is found to drop suddenly from a superheated condition to a saturated condition at the end period of PRHR operation.

  10. Geophysical-log and hydraulic-test analyses of groundwater-production wells at the Hannahville Indian Community, Menominee County, Michigan

    Science.gov (United States)

    Bayless, E. Randall; Anderson, J. Alton; Lampe, David C.; Williams, John H.

    2013-01-01

    The U.S. Geological Survey, in cooperation with the Hannahville Indian Community, evaluated the geohydrology of the bedrock formations and hydraulic properties of groundwater-production wells at the Hannahville Indian Community in Menominee County, Michigan. Geophysical logs were collected from five wells at two sites during September 2012. The logs were analyzed to characterize the lithostratigraphy, bedding and fractures, and hydraulic properties of the geologic formations and aquifers beneath the Hannahville Indian Community. The geophysical logs collected included natural gamma radiation, electromagnetic conductivity, wellbore image, caliper, ambient and stressed flowmeter, fluid resistivity, temperature, and wellbore deviation. The geophysical logs were analyzed with results from short-term hydraulic tests to estimate the transmissivity and water-level altitudes of flow zones penetrated by the wells. The geophysical log analysis indicated the wells penetrated four distinct lithostratigraphic units—shale and carbonate rock, upper carbonate rock, carbonate rock and glauconitic sandstone, and lower carbonate rock. Most of the fractures penetrated by the wellbores appeared to be related bedding partings. The lower carbonate rock unit contained solution features. Analysis of the geophysical logs and hydraulic tests indicated that each of the five wells penetrated from one to four flow zones. The Casino 5 well penetrated a flow zone that was associated with solution features and had an estimated total transmissivity of 4,280 feet squared per day (ft2/d), the highest estimate for all the wells. The Casino 3 well penetrated four flow zones and had an estimated total transmissivity of 3,570 ft2/d. The flow zones penetrated in the lower carbonate rock unit by the Casino 3 and 5 wells were hydraulically connected. The Golf Shack well penetrated two flow zones and had an estimated total transmissivity of 40 ft2/d, the lowest estimate for all the wells. The Community 1

  11. Mass Transfer And Hydraulic Testing Of The V-05 And V-10 Contactors With The Next Generation Solvent

    Energy Technology Data Exchange (ETDEWEB)

    Herman, D. T.; Duignan, M. R.; Williams, M. R.; Peters, T. B.; Poirier, M. R.; Fondeur, F. F.

    2013-07-31

    The Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU) facility is actively pursuing the transition from the current BOBCalixC6 based solvent to the Next Generation Solvent (NGS)-MCU solvent. To support this integration of NGS into the MCU facilities, Savannah River Remediation (SRR) requested that Savannah River National Laboratory (SRNL) perform testing of a blend of the NGS (MaxCalix based solvent) with the current solvent (BOBCalixC6 based solvent) for the removal of cesium (Cs) from the liquid salt waste stream. This testing differs from prior testing by utilizing a blend of BOBCalixC6 based solvent and the NGS with the full (0.05 M) concentration of the MaxCalix as well as a new suppressor, tris(3,7dimethyloctyl) guanidine. Single stage tests were conducted using the full size V-05 and V-10 centrifugal contactors installed at SRNL. These tests were designed to determine the mass transfer and hydraulic characteristics with the NGS solvent blended with the projected heel of the BOBCalixC6 based solvent that will exist in MCU at time of transition. The test program evaluated the amount of organic carryover and the droplet size of the organic carryover phases using several analytical methods. Stage efficiency and mass distribution ratios were determined by measuring Cs concentration in the aqueous and organic phases during single contactor testing. The nominal cesium distribution ratio, D(Cs) measured for extraction ranged from 37-60. The data showed greater than 96% stage efficiency for extraction. No significant differences were noted for operations at 4, 8 or 12 gpm aqueous salt simulant feed flow rates. The first scrub test (contact with weak caustic solution) yielded average scrub D(Cs) values of 3.3 to 5.2 and the second scrub test produced an average value of 1.8 to 2.3. For stripping behavior, the “first stage” D Cs) values ranged from 0.04 to 0.08. The efficiency of the low flow (0.27 gpm aqueous) was calculated to be 82.7%. The Spreadsheet

  12. Analysis of Hydraulic Responses from the ER-6-1 Multiple-Well Aquifer Test, Yucca Flat FY 2004 Testing Program, Nevada Test Site, Nye County, Nevada, Rev. No.: 0

    Energy Technology Data Exchange (ETDEWEB)

    Greg Ruskauff

    2005-06-01

    This report documents the interpretation and analysis of the hydraulic data collected for the Fiscal Year (FY) 2004 Multiple-Well Aquifer Test-Tracer Test (MWAT-TT) conducted at the ER-6-1 Well Cluster in Yucca Flat Corrective Action Unit (CAU) 97, on the Nevada Test Site (NTS). The MWAT-TT was performed to investigate CAU-scale groundwater flow and transport processes related to the transport of radionuclides from sources on the NTS through the Lower Carbonate Aquifer (LCA) Hydrostratigraphic Unit (HSU). The ER-6-1 MWAT-TT was planned and executed by contractor participants for the Underground Test Area (UGTA) Project of the Environmental Restoration (ER) program of the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO). Participants included Stoller-Navarro Joint Venture (SNJV), the Environmental Engineering Services Contractor; Bechtel Nevada (BN); the Desert Research Institute (DRI); Los Alamos National Laboratory; and the University of Nevada, Las Vegas-Harry Reid Center. The SNJV team consists of the S.M. Stoller Corporation, Navarro Research and Engineering, Battelle Memorial Institute, INTERA Inc., and Weston Solutions, Inc. The MWAT-TT was implemented according to the ''Underground Test Area Project, ER-6-1 Multi-Well Aquifer Test - Tracer Test Plan'' (SNJV, 2004a) issued in April 2004. The objective of the aquifer test was to determine flow processes and local hydraulic properties for the LCA through long-term constant-rate pumping at the well cluster. This objective was to be achieved in conjunction with detailed sampling of the composite tracer breakthrough at the pumping well, as well as with depth-specific sampling and logging at multiple wells, to provide information for the depth-discrete analysis of formation hydraulic properties, particularly with regard to fracture properties.

  13. Retrieval process development and enhancements: Hydraulic test bed integrated testing. Fiscal year 1995 technology development summary report

    Energy Technology Data Exchange (ETDEWEB)

    Hatchell, B.K.; Smalley, J.T.; Tucker, J.C.

    1996-02-01

    The Retrieval Process Development and Enhancements Program is sponsored by the U.S. Department of Energy (DOE) Office of Science and Technology to investigate waste dislodging and conveyance processes suitable for the retrieval of high-level radioactive waste. This program, represented by industry, national laboratories, and academia, is testing the performance of a technology of high-pressure waterjet dislodging and pneumatic conveyance integrated as a scarifier as a means of retrieval of waste inside waste storage tanks. Waste stimulants have been designed to challenge this retrieval process, and this technology has been shown to mobilize and convey the waste stimulants, at target retrieval rates while operating within the space envelope and the dynamic loading constraints of postulated deployment systems. The approach has been demonstrated to be versatile in dislodging and conveying a broad range of waste forms, from hard wastes to soft sludge wastes, through the use of simple and reliable in-tank components.

  14. Hydraulic development of high specific-speed pump-turbines by means of an inverse design method, numerical flow-simulation (CFD) and model testing

    Science.gov (United States)

    Kerschberger, P.; Gehrer, A.

    2010-08-01

    In recent years an increased interest in pump-turbines has been recognized in the market. The rapid availability of pumped storage schemes and the benefits to the power system by peak lopping, providing reserve and rapid response for frequency control are becoming of growing advantage. In that context it is requested to develop pump-turbines that reliably stand dynamic operation modes, fast changes of the discharge rate by adjusting the variable diffuser vanes as well as fast changes from pump to turbine operation. Within the present study various flow patterns linked to the operation of a pump-turbine system are discussed. In that context pump and turbine mode are presented separately and different load cases at both operation modes are shown. In order to achieve modern, competitive pump-turbine designs it is further explained which design challenges should be considered during the geometry definition of a pump-turbine impeller. Within the present study a runner-blade profile for a low head pump-turbine has been developed. For the initial hydraulic runner-blade design, an inverse design method has been applied. Within this design procedure, a first blade geometry is generated by imposing the pressure loading-distribution and by means of an inverse 3D potential-flow-solution. The hydraulic behavior of both, pump-mode and turbine-mode is then evaluated by solving the full 3D Navier-Stokes equations in combination with a robust turbulence model. Based on this initial design the blade profile has been further optimized and redesigned considering various hydraulic pump-turbine requirements. Finally, the progress in hydraulic design is demonstrated by model test results which show a significant improvement in hydraulic performance compared to an existing reference design.

  15. Hydraulic development of high specific-speed pump-turbines by means of an inverse design method, numerical flow-simulation (CFD) and model testing

    Energy Technology Data Exchange (ETDEWEB)

    Kerschberger, P; Gehrer, A, E-mail: peter.kerschberger@andritz.co [Andritz Hydro Graz A-8045 Graz, Reichsstrasse 68B (Austria)

    2010-08-15

    In recent years an increased interest in pump-turbines has been recognized in the market. The rapid availability of pumped storage schemes and the benefits to the power system by peak lopping, providing reserve and rapid response for frequency control are becoming of growing advantage. In that context it is requested to develop pump-turbines that reliably stand dynamic operation modes, fast changes of the discharge rate by adjusting the variable diffuser vanes as well as fast changes from pump to turbine operation. Within the present study various flow patterns linked to the operation of a pump-turbine system are discussed. In that context pump and turbine mode are presented separately and different load cases at both operation modes are shown. In order to achieve modern, competitive pump-turbine designs it is further explained which design challenges should be considered during the geometry definition of a pump-turbine impeller. Within the present study a runner-blade profile for a low head pump-turbine has been developed. For the initial hydraulic runner-blade design, an inverse design method has been applied. Within this design procedure, a first blade geometry is generated by imposing the pressure loading-distribution and by means of an inverse 3D potential-flow-solution. The hydraulic behavior of both, pump-mode and turbine-mode is then evaluated by solving the full 3D Navier-Stokes equations in combination with a robust turbulence model. Based on this initial design the blade profile has been further optimized and redesigned considering various hydraulic pump-turbine requirements. Finally, the progress in hydraulic design is demonstrated by model test results which show a significant improvement in hydraulic performance compared to an existing reference design.

  16. Thermal hydraulic performance testing of printed circuit heat exchangers in a high-temperature helium test facility

    Energy Technology Data Exchange (ETDEWEB)

    Sai K. Mylavarapu; Xiaodong Sun; Richard E. Glosup; Richard N. Christensen; Michael W. Patterson

    2014-04-01

    In high-temperature gas-cooled reactors, such as a very high temperature reactor (VHTR), an intermediate heat exchanger (IHX) is required to efficiently transfer the core thermal output to a secondary fluid for electricity generation with an indirect power cycle and/or process heat applications. Currently, there is no proven high-temperature (750–800 °C or higher) compact heat exchanger technology for high-temperature reactor design concepts. In this study, printed circuit heat exchanger (PCHE), a potential IHX concept for high-temperature applications, has been investigated for their heat transfer and pressure drop characteristics under high operating temperatures and pressures. Two PCHEs, each having 10 hot and 10 cold plates with 12 channels (semicircular cross-section) in each plate are fabricated using Alloy 617 plates and tested for their performance in a high-temperature helium test facility (HTHF). The PCHE inlet temperature and pressure were varied from 85 to 390 °C/1.0–2.7 MPa for the cold side and 208–790 °C/1.0–2.7 MPa for the hot side, respectively, while the mass flow rate of helium was varied from 15 to 49 kg/h. This range of mass flow rates corresponds to PCHE channel Reynolds numbers of 950 to 4100 for the cold side and 900 to 3900 for the hot side (corresponding to the laminar and laminar-to-turbulent transition flow regimes). The obtained experimental data have been analyzed for the pressure drop and heat transfer characteristics of the heat transfer surface of the PCHEs and compared with the available models and correlations in the literature. In addition, a numerical treatment of hydrodynamically developing and hydrodynamically fully-developed laminar flow through a semicircular duct is presented. Relations developed for determining the hydrodynamic entrance length in a semicircular duct and the friction factor (or pressure drop) in the hydrodynamic entry length region for laminar flow through a semicircular duct are given. Various

  17. Three types of $\\gamma$-ray bursts

    CERN Document Server

    Mukherjee, S; Babu, G J; Murtagh, F; Fraley, C; Raftery, A E; Mukherjee, Soma; Feigelson, Eric D.; Babu, Gutti Jogesh; Murtagh, Fionn; Fraley, Chris; Raftery, Adrian

    1998-01-01

    A multivariate analysis of gamma-ray burst (GRB) bulk properties is presented to discriminate between distinct classes of GRBs. Several variables representing burst duration, fluence and spectral hardness are considered. Two multivariate clustering procedures are used on a sample of 797 bursts from the Third BATSE Catalog: a nonparametric average linkage hierarchical agglomerative clustering procedure validated with Wilks' $\\Lambda^*$ and other MANOVA tests; and a parametric maximum likelihood model-based clustering procedure assuming multinormal populations calculated with the EM Algorithm and validated with the Bayesian Information Criterion. The two methods yield very similar results. The BATSE GRB population consists of three classes with the following Duration/Fluence/Spectrum bulk properties: Class I with long/bright/intermediate bursts, Class II with short/hard/faint bursts, and Class III with intermediate/intermediate/soft bursts. One outlier with poor data is also present. Classes I and II correspond...

  18. Hydraulic Stability of Accropode Armour

    DEFF Research Database (Denmark)

    Jensen, T.; Burcharth, H. F.; Frigaard, Peter

    , and to assess the influence of core permeability on the hydraulic stability of Accropodes. Two structures were examined, one with a relatively permeable core and one with a relatively impermeable core. In November/December 1995, Ph.D.-student Marten Christensen carried out the model tests on the structure...... with permeable core (crushed granite with a gradation of 5-8 mm). The outcome of this study is described in "Hydraulic Stability of Single-Layer Dolos and Accropode Armour Layers" by Christensen & Burcharth (1995). In January/February 1996, Research Assistant Thomas Jensen carried out a similar study......The present report describes the hydraulic model tests of Accropode armour layers carried out at the Hydraulics Laboratory at Aalborg University from November 1995 through March 1996. The objective of the model tests was to investigate the hydraulic stability of Accropode armour layers...

  19. Hydraulic Stability of Accropode Armour

    DEFF Research Database (Denmark)

    Jensen, T.; Burcharth, H. F.; Frigaard, Peter

    , and to assess the influence of core permeability on the hydraulic stability of Accropodes. Two structures were examined, one with a relatively permeable core and one with a relatively impermeable core. In November/December 1995, Ph.D.-student Marten Christensen carried out the model tests on the structure...... with permeable core (crushed granite with a gradation of 5-8 mm). The outcome of this study is described in "Hydraulic Stability of Single-Layer Dolos and Accropode Armour Layers" by Christensen & Burcharth (1995). In January/February 1996, Research Assistant Thomas Jensen carried out a similar study......The present report describes the hydraulic model tests of Accropode armour layers carried out at the Hydraulics Laboratory at Aalborg University from November 1995 through March 1996. The objective of the model tests was to investigate the hydraulic stability of Accropode armour layers...

  20. 液压泵性能检测实验台设计及检测分析%Design of Performance Test System for Hydraulic Pump

    Institute of Scientific and Technical Information of China (English)

    武金良; 赵坚; 于浩

    2016-01-01

    液压泵是液压系统中的动力元件,其性能的优劣直接影响到液压系统的工作。因此,对其进行性能检测十分必要。引入绿色设计理念,设计了液压泵性能检测系统,并进行了实测验证,保证了系统检测数据的精度,提高了检测效率。%The hydraulic pump is the drive component of the hydraulic system, its performance will directly affect the normal work of hydraulic system. Therefore, it is very necessary to test its performance. The concept of green design was introduced, the hy⁃draulic pump performance test system was designed, and the verification was completed. So the accuracy of the system is guaranteed, and its detecting efficiency is improved obviously.

  1. Experimental studies on heat transfer characteristics and natural circulation performance of PRHRS of the high temperature and high pressure thermal-hydraulic test facility

    Energy Technology Data Exchange (ETDEWEB)

    Park, H. S.; Choi, K. Y.; Joe, S.; Park, C. K.; Lee, S. J.; Song, C. W.; Jeong, M. K. [KAERI, Taejon (Korea, Republic of)

    2003-10-01

    Several experiments are performed to investigate the heat transfer characteristics and natural circulation performance of passive residual removal system (PRHRS) of the high temperature and high pressure thermal-hydraulic test facility. Especially the natural circulation performance of PRHRS, the heat transfer characteristics of PRHRS heat exchangers and emergency cooldown tank (ECT), and the thermal-hydraulic behavior of the primary loop are investigated in detail. The coolant flows steadily in the natural circulation loop which is composed of the steam generator (SG) primary side, the secondary system, and the PRHRS. The heat transfers through the PRHRS heat exchanger and ECT are sufficient enough to enable the natural circulation of the coolant. Also the experimental results show that the core decay heat are sufficiently removed with the operation of the PRHRS.

  2. A test of the millisecond magnetar central engine model of gamma-ray bursts with swift data

    Energy Technology Data Exchange (ETDEWEB)

    Lü, Hou-Jun; Zhang, Bing, E-mail: lhj@physics.unlv.edu, E-mail: zhang@physics.unlv.edu [Department of Physics and Astronomy, University of Nevada Las Vegas, Las Vegas, NV 89154 (United States)

    2014-04-10

    A rapidly spinning, strongly magnetized neutron star (magnetar) has been proposed as one possible candidate of the central engine of gamma-ray bursts (GRBs). We systematically analyze the Swift/XRT light curves of long GRBs detected before 2013 August, and characterize them into four categories based on how likely they may harbor a magnetar central engine: Gold, Silver, Aluminum, and Non-magnetar. We also independently analyze the data of short GRBs with a putative magnetar central engine. We then perform a statistical study of various properties of the magnetar samples and the non-magnetar sample, and investigate whether the data are consistent with the hypothesis that there exist two types of central engines. By deriving the physical parameters of the putative magnetars, we find that the observations of the Gold and Silver samples are generally consistent with the predictions of the magnetar model. For a reasonable beaming factor for long GRBs, the derived magnetar surface magnetic field B{sub p} and initial spin period P {sub 0} fall into the reasonable range. Magnetar winds in short GRBs, on the other hand, are consistent with being isotropic. No GRB in the magnetar sample has a beam-corrected total energy exceeding the maximum energy budget defined by the initial spin energy of the magnetar, while some non-magnetar GRBs do violate such a limit. With beaming correction, on average the non-magnetar sample is more energetic and luminous than the magnetar samples. Our analysis hints that millisecond magnetars are likely operating in a good fraction, but probably not all, GRBs.

  3. Studies of field test procedures in hydraulic turbines for SHP; Estudos de procedimentos de ensaios de campo em turbinas hidraulicas para PCH

    Energy Technology Data Exchange (ETDEWEB)

    Justino, Lucimary Aparecida

    2006-07-01

    A supply contract of equipment for Small Hydro Power, contain the power and turbine efficiency guarantees and can contain adds guarantees referring to a rotation and pressure variation, runaway speed and cavitations test. To the determination about the hydraulics turbines performance for contractual guarantees are realized the field acceptance test, that are methods quite a lot used for enterprises like tools to prove the contractual guarantees in substitution to model test, that showed a cost extremely high. In the field acceptance test are measures of some values that added to the others, possibility obtain the turbine efficiency. In the small hydro power, the turbine efficiency represents the hydraulic power percentage that is subject to be transformed in electrical power. In the turbine purchase, the manufacturer has to guarantee the efficiency specified if it is become down to expected, the damages are enormous, then the importance to exist precise methods and reliable for your measurement. The method accuracy of the discharge measurement that has, between another problems, the calibration and installation, that influence hard the value of the efficiency obtained. This work shows the different methodologies about discharge measurement in hydraulic turbines, that can be apply in Small Hydro Power field tests and shows too the procedures used that in specifics cases of small hydro, without quality damage, the site tests could be executed the form that the guarantees will be approve with compatible cots with the investment done. As an example for said above, are show two cases in small hydro where did realized field acceptance tests to assure the contractual guarantees. (author)

  4. Plan for IER-443 Testing of the Y-12 and AWE Criticality Accident Alarm System Detectors at the Godiva IV Burst Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Scorby, J. C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Hickman, D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Hudson, B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Garbett, S. [Atomic Weapons Establishment (AWE), Berkshire (United Kingdom); Auld, G. [Atomic Weapons Establishment (AWE), Berkshire (United Kingdom); Horrne, A. [Atomic Weapons Establishment (AWE), Berkshire (United Kingdom); Beller, T. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Goda, J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Haught, C. [Y-12 National Security Complex, Oak Ridge, TN (United States); Woodrow, C. [Y-12 National Security Complex, Oak Ridge, TN (United States); Ward, D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-24

    This document provides the scope and details of the “Plan for Testing the Y-12 and AWE Criticality Accident Alarm System Detectors at the Godiva IV Burst Reactor”. Due to the relative simplicity of the testing goals, scope, and methodology, the NCSP Manager approved execution of the test when ready. No preliminary CED-1 or final design CED-2 reports were required or issued. The test will subject Criticality Accident Alarm System (CAAS) detectors supplied by Y- 12 and AWE to very intense and short duration mixed neutron and gamma radiation fields. The goals of the test will be to (1) substantiate functionality, for both existing and newly acquired Y- 12 CAAS detectors, and (2) the ability of the AWE detectors to provide quality temporal dose information after a hypothetical criticality accident. ANSI/ANS-8.3.1997 states that the “system shall be sufficiently robust as to actuate an alarm signal when exposed to the maximum radiation expected”, which has been defined at Y-12, in Documented Safety Analyses (DSAs), to be a dose rate of 10 Rad/s. ANSI/ANS-8.3.1997 further states that “alarm actuation shall occur as a result of a minimum duration transient” which may be assumed to be 1 msec. The pulse widths and dose rates which will be achieved in this test will exceed these requirements. Pulsed radiation fields will be produced by the Godiva IV fast metal burst reactor at the National Criticality Experimental Research Center (NCERC) at the Nevada National Security Site (NNSS). The magnitude of the pulses and the relative distances to the detectors will be varied to afford a wide range of radiation fluence and pulse widths. The magnitude of the neutron and gamma fields will be determined by reactor temperature rise to fluence and dose conversions which have been previously established through extensive measurements performed under IER-147. The requirements for CAAS systems to detect and alarm under a “minimum accident of concern” as well as other

  5. Simulation and test for hydraulic electromagnetic energy-regenerative shock absorber%液电式馈能减振器外特性仿真与试验

    Institute of Scientific and Technical Information of China (English)

    张晗; 过学迅; 徐琳; 张杰

    2014-01-01

    With the rising concerns of global environmental issues, energy saving in automobiles becomes an important subject. In order to achieve the purpose of vibration reduction, the traditional passive shock absorber converts the vehicle vibration energy to thermal energy, and then the thermal energy is released into the air. However, the energy-regenerative shock absorber could harvest this part of the energy. This paper presents a vehicular hydraulic electromagnetic energy-regenerative shock absorber (HESA) which is designed for acquiring the vibration energy caused by road irregularity. It is composed of a hydraulic cylinder, two check valves, two accumulators, a hydraulic motor, a generator, and hydraulic lines. When the vehicle is subjected to vertical vibration, the oil in the HESA flows to the hydraulic motor through a hydraulic line, then the rotating hydraulic motor drives a generator to produce electricity. In order to consider the vibration reduction performance of the HESA, the damping characteristic was analyzed in detail. Through theoretical analysis, the damping force mathematical model of the HESA was deduced, and the calculation program was written in MATLAB, based on the HESA damping force mathematical model. The indicator diagram characteristic and speed characteristic of the HESA under the working condition of a sinusoidal displacement input of 1.67Hz was obtained from simulation tests, which was designed according to a national absorber test procedure. A test bench was constructed to verify the results of a simulation. The comparison between the bench test data and simulation data showed that the value of a compression travel damping force was smaller than the rebound travel’s, and the peak value of the simulation data was identical with the value in test data. The simulation speed characteristic curve of the HESA was compared with the bench test data. However, there were some distortions in the test indicator diagram characteristic curve because

  6. Hydraulic hoist-press

    Energy Technology Data Exchange (ETDEWEB)

    Babayev, Z.B.; Abashev, Z.V.

    1982-01-01

    The efficiency expert of the Angrenskiy production-technological administration of the production association Sredazugol A. V. Bubnov has suggested a hydraulic hoist-press for repairing road equipment which is a device consisting of lifting mechanism, press and test stand for verifying the high pressure hoses and pumps.

  7. Modelling of Hydraulic Robot

    DEFF Research Database (Denmark)

    Madsen, Henrik; Zhou, Jianjun; Hansen, Lars Henrik

    1997-01-01

    This paper describes a case study of identifying the physical model (or the grey box model) of a hydraulic test robot. The obtained model is intended to provide a basis for model-based control of the robot. The physical model is formulated in continuous time and is derived by application...

  8. Thermal-mechanical and thermal-hydraulic integrated study of the Helium-Cooled Lithium Lead Test Blanket Module

    Energy Technology Data Exchange (ETDEWEB)

    Chiovaro, P., E-mail: pg.chiovaro@din.unipa.it [Dipartimento di Ingegneria Nucleare, Universita di Palermo, Palermo (Italy); Di Maio, P.A.; Giammusso, R.; Lupo, Q.; Vella, G. [Dipartimento di Ingegneria Nucleare, Universita di Palermo, Palermo (Italy)

    2010-12-15

    The Helium-Cooled Lithium Lead Test Blanket Module (HCLL-TBM) is one of the two TBM to be installed in an ITER equatorial port since day 1 of operation, with the specific aim to investigate the main concept functionalities and issues such as high efficiency helium cooling, resistance to thermo-mechanical stresses, manufacturing techniques, as well as tritium transport, magneto-hydrodynamics effects and corrosion. In particular, in order to show a DEMO-relevant thermo-mechanical and thermal-hydraulic behavior, the HCLL-TBM has to meet several requirements especially as far as its coolant thermofluid-dynamic conditions and its thermal-mechanical field are concerned. The present paper is focused on the assessment of the HCLL-TBM thermal-mechanical performances under both nominal and accidental load conditions, by adopting a computational approach based on the Finite Element Method. A realistic 3D finite element model of the whole HCLL-TBM, in the horizontal first wall design has been set up, consisting of about 597,000 elements and 767,000 nodes. In particular, since the thermal fields of both the module and the coolant are strictly coupled, the helium flow domain has been modeled too and a thermal contact model has been set up to properly simulate the convective heat transfer between the structure wall and the coolant. Pure conductive heat transfer has been assumed within the Pb-Li eutectic alloy of the breeder units. The volumetric density of the nuclear deposited power, recently calculated at Department of Nuclear Engineering of the University of Palermo by the MCNP 4C code, has been applied as distributed thermal load in order to assess the potential influence on the module thermo-mechanical performances of the markedly non-uniform poloidal and toroidal distributions that have been predicted within the Segment Box. Different loading scenarios have been considered as to the heat flux onto the module First Wall. Steady state and transient thermal-mechanical analyses

  9. Simulation of the passive condensation cooling tank of the PASCAL test facility using the component thermal-hydraulic analysis code CUPID

    Energy Technology Data Exchange (ETDEWEB)

    Cho, H. K.; Lee, S. J.; Kang, K. H.; Yoon, H. Y. [Korea Atomic Energy Research Inst., 1045 Daeduk-daero, Daejeon (Korea, Republic of)

    2012-07-01

    For the analysis of transient two-phase flows in nuclear reactor components, a three-dimensional thermal hydraulics code, named CUPID, has been being developed. In the present study, the CUPID code was applied for the simulation of the PASCAL (PAFS Condensing Heat Removal Assessment Loop) test facility constructed with an aim of validating the cooling and operational performance of the PAFS (Passive Auxiliary Feedwater System). The PAFS is one of the advanced safety features adopted in the APR+ (Advanced Power Reactor +), which is intended to completely replace the conventional active auxiliary feedwater system. This paper presents the preliminary simulation results of the PASCAL facility performed with the CUPID code in order to verify its applicability to the thermal-hydraulic phenomena inside the system. A standalone calculation for the passive condensation cooling tank was performed by imposing a heat source boundary condition and the transient thermal-hydraulic behaviors inside the system, such as the water level, temperature and velocity, were qualitatively investigated. The simulation results verified that the natural circulation and boiling phenomena in the water pool can be well reproduced by the CUPID code. (authors)

  10. Simulation of the Passive Condensation Cooling Tank of the PASCAL Test Facility using the Component Thermal-hydraulic Analysis Code CUPID

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Hyoung Kyu; Lee, Seung Jun; Yoon, Han Young [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    The need for a multi-dimensional analysis of transient thermal hydraulic phenomena in a component of a nuclear reactor is increasing with the advanced design features, such as a direct vessel injection system, a gravity-driven safety injection system, and a passive cooling system. Motivated by this, the development of a new thermal-hydraulic analysis code, named CUPID, is in progress at KAERI (Korea Atomic Energy Research Institute). Its numerical solver and two-phase flow models have been verified against standard conceptual problems of single and two-phase flows and validated for thermal-hydraulic experiments in our previous studies. The simulation of the passive secondary cooling system, PAFS (Passive Auxiliary Feedwater System) has been considered as one of the practical applications of CUPID. In the present study, the PCCT (Passive Condensation Cooling Tank) of the PASCAL test facility was analyzed with CUPID prior to simulating the prototype PAFS system. The objectives of the PASCAL simulation were to validate physical models of CUPID and its applicability to the PAFS analysis. This paper presents the two-dimensional transient calculation results and the comparisons with the experimental data

  11. Analysing the scalability of thermal hydraulic test facility data to reactor scale with a computer code; Vertailuanalyysin kaeyttoe termohydraulisten koelaitteistojen tulosten laitosmittakaavaan skaalautumisen tutkimisessa

    Energy Technology Data Exchange (ETDEWEB)

    Suikkanen, P.

    2009-01-15

    The objective of the Masters thesis was to study guidelines and procedures for scaling of thermal hydraulic test facilities and to compare results from two test facility models and from EPR model. Aim was to get an impression of how well the studied test facilities describe the behaviour in power plant scale during accident scenarios with computer codes. Models were used to determine the influence of primary circuit mass inventory on the behaviour of the circuit. The data from test facility models represent the same phenomena as the data from EPR model. The results calculated with PKL model were also compared against PKL test facility data. They showed good agreement. Test facility data is used to validate computer codes, which are used in nuclear safety analysis. The scale of the facility has effect on the behaviour of the phenomena and therefore special care must be taken in using the data. (orig.)

  12. 大型水电站福伊特水轮机模型试验研究%The Test and Study on the Voith Hydraulic Turbine Model of a Large Hydropower Plant

    Institute of Scientific and Technical Information of China (English)

    李冬亮

    2014-01-01

    为了检验某大型水电站水轮机的水力特性,进行了水轮机福伊特模型验收试验,包括尺寸检查、效率试验、出力试验、飞逸试验、空化试验、蜗壳差压试验、压力脉动试验、导叶水力矩试验、轴向水推力试验、筒阀下拉力试验等内容。试验结果表明:模型水轮机及换算得到的原型的效率、出力、空化、压力脉动、飞逸、轴向水推力、导叶水力矩、筒阀压力等性能指标均满足合同技术要求。%In order to test the hydraulic characteristics of the hydraulic turbines of a large hydropower plant the Yoith hydraulic turbine model acceptance tests were conducted ,including dimensions check ,efficiency test ,output test ,runaway test ,cavitation test ,spiral case differential pressure test ,pressure fluctuation test ,guide vane hydraulic torque test ,axial hydraulic thrust test and cylinder tensile test .T he test results show that the performance indexes of the model turbine and those converted from the prototype such as ef-ficiency ,pressure fluctuation ,runaway ,guide vane hydraulic torque ,axial hydraulic thrust and cylinder valve pressure all meet the technical requirements of the contract .

  13. Study of Hydraulic Support Sealing Performance Test Specification%液压支架密封性能试验规范的研究

    Institute of Scientific and Technical Information of China (English)

    薛春明

    2015-01-01

    Due to the lack of performance evaluation system of hydraulic support’s sealing property in current domestic, through the re-search, a set of complete sealing performance test specification is put forward. Firstly, the general structure and the operating principle of the test bed’s hydraulic support sealing performance were introduced. Then we discussed the test conditions and test requirements. Finally, the specific test method was presented.%由于目前国内缺乏完善的液压支架密封性能评价体系,通过研究提出了一套完整的密封性能试验规范。首先介绍了液压支架密封性能试验台的总体结构及工作原理,讨论了试验条件,试验要求,最后给出了具体试验方法。

  14. Thalamic Bursts Down-regulate Cortical Theta and Nociceptive Behavior.

    Science.gov (United States)

    LeBlanc, Brian W; Cross, Brent; Smith, Kelsey A; Roach, Catherine; Xia, Jimmy; Chao, Yu-Chieh; Levitt, Joshua; Koyama, Suguru; Moore, Christopher I; Saab, Carl Y

    2017-05-30

    We tested the relation between pain behavior, theta (4-8 Hz) oscillations in somatosensory cortex and burst firing in thalamic neurons in vivo. Optically-induced thalamic bursts attenuated cortical theta and mechanical allodynia. It is proposed that thalamic bursts are an adaptive response to pain that de-synchronizes cortical theta and decreases sensory salience.

  15. Thermal Hydraulic Performance of Tight Lattice Bundle

    Science.gov (United States)

    Yamamoto, Yasushi; Akiba, Miyuki; Morooka, Shinichi; Shirakawa, Kenetsu; Abe, Nobuaki

    Recently, the reduced moderation spectrum BWR has been studied. The fast neutron spectrum is obtained through triangular tight lattice fuel. However, there are few thermal hydraulic test data and thermal hydraulic correlation applicable to critical power prediction in such a tight lattice bundle. This study aims to enhance the database of the thermal hydraulic performance of the tight lattice bundle whose rod gap is about 1mm. Therefore, thermal hydraulic performance measurement tests of tight lattice bundles for the critical power, the pressure drop and the counter current flow limiting were performed. Moreover, the correlations to evaluate the thermal-hydraulic performance of the tight lattice bundle were developed.

  16. Characterizing Hydraulic Properties and Ground-Water Chemistry in Fractured-Rock Aquifers: A User's Manual for the Multifunction Bedrock-Aquifer Transportable Testing Tool (BAT3)

    Science.gov (United States)

    Shapiro, Allen M.

    2007-01-01

    A borehole testing apparatus has been designed to isolate discrete intervals of a bedrock borehole and conduct hydraulic tests or collect water samples for geochemical analyses. This borehole testing apparatus, referred to as the Multifunction Bedrock-Aquifer Transportable Testing Tool (BAT3), includes two borehole packers, which when inflated can form a pressure-tight seal against smooth borehole walls; a pump apparatus to withdraw water from between the two packers; a fluid-injection apparatus to inject water between the two packers; pressure transducers to monitor fluid pressure between the two packers, as well as above and below the packers; flowmeters to monitor rates of fluid withdrawal or fluid injection; and data-acquisition equipment to record and store digital records from the pressure transducers and flowmeters. The generic design of this apparatus was originally discussed in United States Patent Number 6,761,062 (Shapiro, 2004). The prototype of the apparatus discussed in this report is designed for boreholes that are approximately 6 inches in diameter and can be used to depths of approximately 300 feet below land surface. The apparatus is designed to fit in five hard plastic boxes that can be shipped by overnight freight car-riers. The equipment can be assembled rapidly once it is removed from the shipping boxes, and the length of the test interval (the distance between the two packers) can be adjusted to account for different borehole conditions without reconfiguring the downhole components. The downhole components of the Multifunction BAT3 can be lowered in a borehole using steel pipe or a cable; a truck mounted winch or a winch and tripod can be used for this purpose. The equipment used to raise and lower the downhole components of the Multifunction BAT3 must be supplied on site, along with electrical power, a compressor or cylinders of compressed gas to inflate the packers and operate downhole valves, and the proper length of tubing to connect the

  17. PETER loop. Multifunctional test facility for thermal hydraulic investigations of PWR fuel elements; PETER Loop. Multifunktionsversuchstand zur thermohydraulischen Untersuchung von DWR Brennelementen

    Energy Technology Data Exchange (ETDEWEB)

    Ganzmann, I.; Hille, D.; Staude, U. [AREVA NP GmbH (Germany). Materials, Fluid-Structure Interaction, Plant Life Management NTCM-G

    2009-07-01

    The reliable fuel element behavior during the complete fuel cycle is one of the fundamental prerequisites of a safe and efficient nuclear power plant operation. The fuel element behavior with respect to pressure drop and vibration impact cannot be simulated by means of fluid-structure interaction codes. Therefore it is necessary to perform tests using fuel element mock-ups (1:1). AREVA NP has constructed the test facility PETER (PWR fuel element tests in Erlangen) loop. The modular construction allows maximum flexibility for any type of fuel elements. Modern measuring instrumentation for flow, pressure and vibration characterization allows the analysis of cause and consequences of thermal hydraulic phenomena. PETER loop is the standard test facility for the qualification of dynamic fuel element behavior in flowing fluid and is used for failure mode analysis.

  18. Characterization of plastic behaviour of sheet metals by hydraulic bulge test%液压胀形金属板材的塑性行为表征

    Institute of Scientific and Technical Information of China (English)

    Lucian L(A)Z(A)RESCU; Dan-Sorin COM(S)A; Ioan NICODIM; Ioan CIOBANU; Dorel BANABIC

    2012-01-01

    In the hydraulic bulge tests,dies with both circular and elliptical apertures were used.A recently proposed methodology was used to determine the equivalent stress—strain curves by bulging through elliptical dies.This methodology combines an analytical approach with the experimental data measured by an ARAMIS system.In the hydraulic bulge test using elliptical dies,as the die ellipticity ratio decreases,the equivalent stress—strain curves tend to move away from the curve obtained from bulging through circular die.The forming limit diagram in the range of positive minor strain of a DC04 sheet steel is also determined by using bulge test.%采用圆形和椭圆形的模具进行液压胀形试验.利用最近提出的椭圆形模具胀形方法来确定等效应力一应变曲线.该方法将ARAMIS系统测得的实验数据与分析相结合.在使用椭圆形模具的液压胀形实验中,随着模具椭圆度的减小,等效应力一应变曲线逐渐远离圆形模具胀形的曲线.通过胀形测试来确定DC04钢板在正次应变范围内的成形极限图.

  19. Burst Mechanisms in Hydrodynamics

    CERN Document Server

    Knobloch, E

    1999-01-01

    Different mechanisms believed to be responsible for the generation of bursts in hydrodynamical systems are reviewed and a new mechanism capable of generating regular or irregular bursts of large dynamic range near threshold is described. The new mechanism is present in the interaction between oscillatory modes of odd and even parity in systems of large but finite aspect ratio, and provides an explanation for the bursting behavior observed in binary fluid convection. Additional applications of the new mechanism are proposed.

  20. Design of a Gear Transmission Loading Fatigue Test Bench Have Ability of Hydraulic Power Recovery%一种液压功率回收型齿轮传动加载疲劳试验台的设计

    Institute of Scientific and Technical Information of China (English)

    王延忠; 刘文; 潘广悦; 刘元鹏

    2016-01-01

    基于液压补偿功率回收理论,采用容积调压加载的方式,结合PLC在液压系统的控制应用,针对试验台的液压系统及测控系统进行设计,并对液压系统的主要液压元件试验参数匹配关系进行理论计算.由理论关系式得出液压马达排量的调节对试验台的驱动转速与加载转矩的影响,并依照系统原理搭建试验台,通过试验检测,得到功率回收效率.%Based on the hydraulic power recovery compensation theory,by ways of regulating the volume of loaded and PLC control applications in the hydraulic system,the hydraulic system,the measurement and control system of the test bench are designed primarily.The composition principle of the hydraulic system and the matching relationship of main hy-draulic components test parameters are calculated.The influence of hydraulic motor displacement on the driving speed and the load torque can be obtained by the theoretical formula,and a test bench is set up to detect the power recovery efficiency.

  1. Hydraulic conductivity of compacted zeolites.

    Science.gov (United States)

    Oren, A Hakan; Ozdamar, Tuğçe

    2013-06-01

    Hydraulic conductivities of compacted zeolites were investigated as a function of compaction water content and zeolite particle size. Initially, the compaction characteristics of zeolites were determined. The compaction test results showed that maximum dry unit weight (γ(dmax)) of fine zeolite was greater than that of granular zeolites. The γ(dmax) of compacted zeolites was between 1.01 and 1.17 Mg m(-3) and optimum water content (w(opt)) was between 38% and 53%. Regardless of zeolite particle size, compacted zeolites had low γ(dmax) and high w(opt) when compared with compacted natural soils. Then, hydraulic conductivity tests were run on compacted zeolites. The hydraulic conductivity values were within the range of 2.0 × 10(-3) cm s(-1) to 1.1 × 10(-7) cm s(-1). Hydraulic conductivity of all compacted zeolites decreased almost 50 times as the water content increased. It is noteworthy that hydraulic conductivity of compacted zeolite was strongly dependent on the zeolite particle size. The hydraulic conductivity decreased almost three orders of magnitude up to 39% fine content; then, it remained almost unchanged beyond 39%. Only one report was found in the literature on the hydraulic conductivity of compacted zeolite, which is in agreement with the findings of this study.

  2. MODFLOW-2005 and PEST models used to simulate multiple-well aquifer tests and characterize hydraulic properties of volcanic rocks in Pahute Mesa, Nevada

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — A three-dimensional, groundwater-flow model (MODFLOW-2005) was developed to estimate the hydraulic properties (e.g., transmissivity, hydraulic conductivity, specific...

  3. Simulation of research loop LOBI-MOD2 with RELAP5/MOD3.3 code for LOBI thermo hydraulic test A1-93

    Energy Technology Data Exchange (ETDEWEB)

    Pesaran, Farshad; Barati, Ramin [Islamic Azad Univ., Shiraz (Iran, Islamic Republic of). Dept. of Electrical Engineering

    2016-06-15

    RELAP5/MOD3.3 is one of the used computer codes for the simulation of event thermal-hydraulics of nuclear power plants. The LOBI test facility is a full-power high-pressure integral system test facility, representing an approximately 1: 700 scale model of a 4-loop, 1300 MWe PWR. A new simulation of the small break LOCA test A1-93 has been carried out in a LOBI/Mod2 facility for reaching good agreement and to evaluate the performance of the RELAP5/MOD3.3 code. Good agreement was obtained in general between the code predictions and the experimental data in transient state.

  4. Analysis of Thermal-Hydraulic Gravity/ Buoyancy Effects in the Testing of the ITER Poloidal Field Full Size Joint Sample (PF-FSJS)

    Science.gov (United States)

    Zanino, R.; Bruzzone, P.; Ciazynski, D.; Ciotti, M.; Gislon, P.; Nicollet, S.; Savoldi Richard, L.

    2004-06-01

    The PF-FSJS is a full-size joint sample, based on the NbTi dual-channel cable-in-conduit conductor (CICC) design currently foreseen for the International Thermonuclear Experimental Reactor (ITER) Poloidal Field coil system. It was tested during the summer of 2002 in the Sultan facility of CRPP at a background peak magnetic field of typically 6 T. It includes about 3 m of two jointed conductor sections, using different strands but with identical layout. The sample was cooled by supercritical helium at nominal 4.5-5.0 K and 0.9-1.0 MPa, in forced convection from the top to the bottom of the vertical configuration. A pulsed coil was used to test AC losses in the two legs resulting, above a certain input power threshold, in bundle helium backflow from the heated region. Here we study the thermal-hydraulics of the phenomenon with the M&M code, with particular emphasis on the effects of buoyancy on the helium dynamics, as well as on the thermal-hydraulic coupling between the wrapped bundles of strands in the annular cable region and the central cooling channel. Both issues are ITER relevant, as they affect the more general question of the heat removal capability of the helium in this type of conductors.

  5. 液压卷带装置动态性能试验研究%Test study on dynamic performance of hydraulic belt-winding device

    Institute of Scientific and Technical Information of China (English)

    戴珊珊

    2011-01-01

    介绍了卷带装置的液压系统组成及工作原理,分析了液压泵的功率特性,搭建了液压卷带装置试验台,介绍了试验原理和硬件组成。通过大量试验,研究了启动时卷带装置的动态性能以及不同负载下系统的恒功率特性。%The constitution and the working principle of the hydraulic system of the belt-winding device are described, and the power characteristics of the hydraulic pump are analyzed. A test bench for the belt-winding device is built and its constitution and working principle are introduced. Based on a large number of tests, dynamic characteristics of the belt-winding device during starting process and constant-power characteristics of the system in different load modes are studied.

  6. Flow Curve Determination at Large Plastic Strain Levels: Limitations of the Membrane Theory in the Analysis of the Hydraulic Bulge Test

    Science.gov (United States)

    Lemoine, X.; Iancu, A.; Ferron, G.

    2011-05-01

    Nowadays, an accurate determination of the true stress-strain curve is a key-element for all finite element (FE) forming predictions. Since the introduction of Advanced High Strength Steels (AHSS) for the automotive market, the standard uniaxial tension test suffers the drawback of relatively low uniform elongations. The extrapolation of the uniaxial stress-strain curve up to large strains is not without consequence in forming predictions—especially formability and springback. One of the means to solve this problem is to use experimental tests where large plastic strain levels can be reached. The hydraulic bulge test is one of these tests. The effective plastic strain levels reached in the bulge test are of about 0.7. From an experimental standpoint, the biaxial flow stress is estimated using measurement of fluid pressure, and calculation of thickness and curvature at the pole, via appropriate measurements and assumptions. The biaxial stress at the pole is determined using the membrane equilibrium equation. The analysis proposed in this paper consists of performing "virtual experiments" where the results obtained by means of FE calculations are used as input data for determining the biaxial stress-strain law in agreement with the experimental procedure. In this way, a critical discussion of the experimental procedure can be made, by comparing the "experimental" stress-strain curve (Membrane theory curve) with the "reference" one introduced in the simulations. In particular, the influences of the "(die diameter)/thickness" ratio and of the plastic anisotropy are studied, and limitations of the hydraulic bulge test analysis are discussed.

  7. Hydraulic wind energy conversion system

    Energy Technology Data Exchange (ETDEWEB)

    1981-07-01

    The purpose of this research was to design, build and test a hydraulic wind energy system. This design used a three bladed turbine, which drove a hydraulic pump. The energy is transmitted from the pump through a long hose and into a hydraulic motor, where the energy is used. This wind system was built and tested during the winter of 1980-1981. The power train included a five meter, three bladed wind turbine, a 9.8:1 ratio gearbox, a 1.44 cubic inch displacement pump with a small supercharge gear pump attached. The hydraulic fluid was pumped through a 70', 3/4'' I-D-high pressure flexhose, then through a volume control valve and into a 1.44 cubic inch displacement motor. The fluid was returned through a 70', 1'' I-D-flexhose.

  8. 基于ANSYS的某型飞机液压管路应力测试%Stress Test of Hydraulic Tubing in Aircraft Based on ANSYS

    Institute of Scientific and Technical Information of China (English)

    史杰; 胡文

    2014-01-01

    In order to minimize the quantity of strain gauges and improve the accuracy in the stress test of hydraulic tubing.Stress analysis based on ANSYS before the test is proposed in this paper. The CATIA mockups of the hydraulic tubing are imported to ANSYS and the stress analysis is carried out by Workbench. The locations of sensors are optimized according to the calculated stress distribution. The data measured in the test is used to optimize the finite element model. The quantity of strain gauges used in the stress test can be minimized and accuracy can be improved in the field test by implementing the proposed method.%为了优化液压管路应力测试,减少测点数量,提高测试准确度,提出在应力测试前用ANSYS对管路进行受力分析,试验后用试验数据进行模型修正。通过对管路进行三维建模,将模型导入ANSYS,分析管路振动时应力分布,根据受力情况确定传感器的安装位置。后将测得的数据修正模型参数,通过模型计算最大应力。通过ANSYS优化应力测试,减少了传感器布置的数量,提高了测试的准确度。

  9. Advanced Performance Hydraulic Wind Energy

    Science.gov (United States)

    Jones, Jack A.; Bruce, Allan; Lam, Adrienne S.

    2013-01-01

    The Jet Propulsion Laboratory, California Institute of Technology, has developed a novel advanced hydraulic wind energy design, which has up to 23% performance improvement over conventional wind turbine and conventional hydraulic wind energy systems with 5 m/sec winds. It also has significant cost advantages with levelized costs equal to coal (after carbon tax rebate). The design is equally applicable to tidal energy systems and has passed preliminary laboratory proof-of-performance tests, as funded by the Department of Energy.

  10. Advanced communications technology satellite high burst rate link evaluation terminal power control and rain fade software test plan, version 1.0

    Science.gov (United States)

    Reinhart, Richard C.

    1993-01-01

    The Power Control and Rain Fade Software was developed at the NASA Lewis Research Center to support the Advanced Communications Technology Satellite High Burst Rate Link Evaluation Terminal (ACTS HBR-LET). The HBR-LET is an experimenters terminal to communicate with the ACTS for various experiments by government, university, and industry agencies. The Power Control and Rain Fade Software is one segment of the Control and Performance Monitor (C&PM) Software system of the HBR-LET. The Power Control and Rain Fade Software automatically controls the LET uplink power to compensate for signal fades. Besides power augmentation, the C&PM Software system is also responsible for instrument control during HBR-LET experiments, control of the Intermediate Frequency Switch Matrix on board the ACTS to yield a desired path through the spacecraft payload, and data display. The Power Control and Rain Fade Software User's Guide, Version 1.0 outlines the commands and procedures to install and operate the Power Control and Rain Fade Software. The Power Control and Rain Fade Software Maintenance Manual, Version 1.0 is a programmer's guide to the Power Control and Rain Fade Software. This manual details the current implementation of the software from a technical perspective. Included is an overview of the Power Control and Rain Fade Software, computer algorithms, format representations, and computer hardware configuration. The Power Control and Rain Fade Test Plan provides a step-by-step procedure to verify the operation of the software using a predetermined signal fade event. The Test Plan also provides a means to demonstrate the capability of the software.

  11. Hydraulic test results for Savage Island wells: 699-32-22B, 699-42-E9A, and 699-42-E9B

    Energy Technology Data Exchange (ETDEWEB)

    Spane, F.A. Jr.

    1992-06-01

    As part of the Ground-Water Surveillance Project, Hanford Site Flow System Characterization Task, Pacific Northwest Laboratory (PNL) examines the potential for offsite migration of contamination within the upper-confined aquifer system. As part of this activity, a hydraulic characterization investigation was conducted on three newly constructed wells. The three wells are collectively referred to as the Savage Island wells, which is in reference to the location of two of the three wells tested during this investigation. Results of characterization tests conducted as part of this investigation will be used by PNL in its assessment of the extent of contamination within the upper-confined aquifer system, and its potential for offsite migration.

  12. 工程机械液压系统性能试验台中的液压泵动态性能试验研究%Experimental Study on Dynamic Performance of Hydraulic Pump of Construction Machinery Hydraulic System Performance Testing Platform

    Institute of Scientific and Technical Information of China (English)

    朱发新; 林少芬; 龚雅萍; 王伟军; 张志斌

    2011-01-01

    Taking the steering system of the construction machinery hydraulic system performance testing platform as physical model, the dynamic performances of the hydraulic pump were studied by local experiments. According to the test results, the influences of motor speed, fuel tank position, load voltage on the hydraulic pump performance as well as the effect of hydraulic pump pressure and flow change to the hydraulic system were obtained.%以工程机械液压系统性能试验台的转向系统为物理模型,通过试验研究液压泵的动态性能.根据试验结果,得出油箱位置、变频电机转速、加载电压等系统工况对液压泵动态性能的影响,同时得出液压泵压力、流量的动态变化对液压系统的影响.

  13. 伺服液压缸压下系统动态特性测试方法研究%Dynamic characteristics test system for Servo hydraul ic cyl inder

    Institute of Scientific and Technical Information of China (English)

    杨清华

    2014-01-01

    Hydraulic system performance depends on hydraulic cylinder to a great extent,so the inspection and test of the hydraulic cylinder has very important practical significance.In this paper,combined with a large steel mill of hydraulic pressure servo system,use computer aided testing system to analyze closed loop frequency response of servo hydraulic cylinder.It is a test without load for closed loop system dynam-ic characteristics.Practice has proved that this test system is simple with accurate result,and it has a wide application prospect.%拥有良好性能的伺服液压缸在液压行业的应用日趋广泛,探索液压缸性能的检测方法有着实用意义。针对某大型钢厂的液压压下伺服系统进行无负载测试,开发了研究伺服液压缸闭环频域响应特性的计算机辅助测试系统。实践证明此测试方法操作简单,测试结果准确,有广泛应用前景。

  14. 适用于动静压试验的综合液压源的设计%A Multifunctional Pump Station Designed for Dynamic and Static Pressure Hydraulic Tests

    Institute of Scientific and Technical Information of China (English)

    孔炫畅

    2015-01-01

    分析了液压元件动静压试验的测试需求,据此进行了液压泵站的设计。液压泵站液压能由电动泵和手动泵提供,满足不同性质的液压实验需求。实践证明,对于实验类型较多,特别是静压实验较多的场合,综合液压源与常规液压源相比,具有明显优势。%Based on the dynamic and static pressure test requirement of hydraulic components, the pump station is designed. The hydraulic power of the pump station is provided by its motor pump and hand pump in accordance with different hydraulic tests. It is proved in practice that the pump station is more adequate than normal hydraulic power source to tests which need the hydraulic pressure to be hold for a long time, such as a leak test.

  15. Testing the skill of numerical hydraulic modeling to simulate spatiotemporal flooding patterns in the Logone floodplain, Cameroon

    Science.gov (United States)

    Fernández, Alfonso; Najafi, Mohammad Reza; Durand, Michael; Mark, Bryan G.; Moritz, Mark; Jung, Hahn Chul; Neal, Jeffrey; Shastry, Apoorva; Laborde, Sarah; Phang, Sui Chian; Hamilton, Ian M.; Xiao, Ningchuan

    2016-08-01

    Recent innovations in hydraulic modeling have enabled global simulation of rivers, including simulation of their coupled wetlands and floodplains. Accurate simulations of floodplains using these approaches may imply tremendous advances in global hydrologic studies and in biogeochemical cycling. One such innovation is to explicitly treat sub-grid channels within two-dimensional models, given only remotely sensed data in areas with limited data availability. However, predicting inundated area in floodplains using a sub-grid model has not been rigorously validated. In this study, we applied the LISFLOOD-FP hydraulic model using a sub-grid channel parameterization to simulate inundation dynamics on the Logone River floodplain, in northern Cameroon, from 2001 to 2007. Our goal was to determine whether floodplain dynamics could be simulated with sufficient accuracy to understand human and natural contributions to current and future inundation patterns. Model inputs in this data-sparse region include in situ river discharge, satellite-derived rainfall, and the shuttle radar topography mission (SRTM) floodplain elevation. We found that the model accurately simulated total floodplain inundation, with a Pearson correlation coefficient greater than 0.9, and RMSE less than 700 km2, compared to peak inundation greater than 6000 km2. Predicted discharge downstream of the floodplain matched measurements (Nash-Sutcliffe efficiency of 0.81), and indicated that net flow from the channel to the floodplain was modeled accurately. However, the spatial pattern of inundation was not well simulated, apparently due to uncertainties in SRTM elevations. We evaluated model results at 250, 500 and 1000-m spatial resolutions, and found that results are insensitive to spatial resolution. We also compared the model output against results from a run of LISFLOOD-FP in which the sub-grid channel parameterization was disabled, finding that the sub-grid parameterization simulated more realistic

  16. High Pressure Hydraulic Distribution System

    Science.gov (United States)

    1991-05-20

    to 500 0 F. 5 cycles. 5000 F room temperature to 50001F; 45 ______________ Icycles The tesis planned for the distribution system demonstrator were...American Society for Testing and Materials ASTM D412 - Tension Testing of Vulcanized Rubber ASTM D571 - Testing Automotive Hydraulic Brake Hose Society of

  17. Testing for reach-scale adjustments of hydraulic variables to soluble and insoluble strata: Buckeye Creek and Greenbrier River, West Virginia

    Science.gov (United States)

    Springer, Gregory S.; Wohl, Ellen E.; Foster, Julie A.; Boyer, Douglas G.

    2003-11-01

    An open question exists as to whether channel geometries and hydraulics are adjusted in bedrock streams with stable, concave profiles in a manner analogous to alluvial rivers. As a test of this problem, a comparison was undertaken of channel geometries and hydraulics among reaches with substrates that are of high mechanical resistance, but of variable chemical resistance. Reaches were selected from Buckeye Creek and Greenbrier River, West Virginia, USA because these streams flow over sandstones, limestones, and shales. The limestones have Selby rock resistance scores similar to those of the sandstones. A total of 13 reaches consisting of between 6 and 26 cross sections were surveyed in the streams. HEC-RAS was used to estimate unit stream power ( ω) and shear stress ( τ) for each reach. The reaches were selected to evaluate the null hypothesis that that ω and τ are equal atop soluble versus insoluble bedrock. Hypothesis tests consisted of paired t-tests and simultaneous, multiple comparisons. Geomorphic setting was included for Greenbrier River because previous studies have suggested that bedrock streams are intimately coupled with hillslopes. Holding geomorphic setting constant, three separate comparisons of ω and τ reveal that these variables are lowest atop soluble substrates in Greenbrier River (significance ≤0.05) and that changes in ω and τ are mediated by changes in channel geometry. Similarly, headwater reaches of Buckeye Creek developed atop shale and sandstone boulders are statistically distinguishable from downstream reaches wherein corrosion of limestone is the primary means of incision. However, comparisons in each stream reveal that channel geometries, ω and τ, are not strictly controlled by bed solubility. For constant substrate solubility along the Greenbrier River, ω and τ are consistently higher where a bedrock cutbank is present or coarse, insoluble sediment enters the channel. The latter is also associated with locally high values

  18. Hydraulic testing of intravascular axial flow blood pump designs with a protective cage of filaments for mechanical cavopulmonary assist.

    Science.gov (United States)

    Kapadia, Jugal Y; Pierce, Kathryn C; Poupore, Amy K; Throckmorton, Amy L

    2010-01-01

    To provide hemodynamic support to patients with a failing single ventricle, we are developing a percutaneously inserted, magnetically levitated axial flow blood pump designed to augment pressure in the cavopulmonary circulation. The device is designed to serve as a bridge-to-transplant, bridge-to-recovery, bridge-to-hemodynamic stability, or bridge-to-surgical reconstruction. This study evaluated the hydraulic performance of three blood pump prototypes (a four-bladed impeller, a three-bladed impeller, and a three-bladed impeller with a four-bladed diffuser) whose designs evolved from previous design optimization phases. Each prototype included the same geometric protective cage of filaments, which stabilize the rotor within the housing and protect the housing wall from the rotating blades. All prototypes delivered pressure rises over a range of flow rates and rotational speeds that would be sufficient to augment hemodynamic conditions in the cavopulmonary circulation. The four-bladed impeller outperformed the two remaining prototypes by >40%; this design was able to generate a pressure rise of 4-28 mm Hg for flow rates of 0.5-10 L/min at rotational speeds of 4,000-7,000 RPM. Successful development of this blood pump will provide clinicians with a feasible therapeutic option for mechanically supporting the failing Fontan.

  19. Evaluation of the ductile-to-brittle transition temperature of a silicon steel under various strain rate conditions with a servo-hydraulic high speed testing machine

    Science.gov (United States)

    Kwon, Junbeom; Huh, Hoon; Kim, Jae-song

    2017-07-01

    This paper is concerned with the construction of an empirical model of the Ductile-to-Brittle Transition Temperature (DBTT) for 3.4% silicon steel based on tensile test results at strain rates ranging from 0.001 s‒1 to 100 s‒1. Dynamic tensile tests are conducted using an in-house servo hydraulic tensile test machine at strain rates of 1 s‒1, 10 s‒1, and 100 s‒1 and quasi-static tensile tests are conducted using Instron 4206 at strain rates of 0.001 s‒1 and 0.01 s‒1 with an environmental chamber. Fracture elongations are measured by a DIC method during all tests using the high-speed camera for accurate measurement. The DBTT of 3.4% silicon steel is presented in terms of fracture strain with the variation of the temperature and the strain rate. It is demonstrated from the test results that the DBTT increases as the strain rate increases. An empirical model of the DBTT is constructed in terms of strain rate, temperature and fracture elongation. The parameters of the empirical model are calculated from experimental results obtained at various temperatures and strain rates.

  20. Shaking table test and verification of development of an accumulated semi-active hydraulic damper as an active interaction control device

    Indian Academy of Sciences (India)

    MING-HSIANG SHIH; WEN-PEI SUNG

    2016-12-01

    Semi-active control is based on the use of the emerging concept of active control and passive control. The developed accumulator semi-active hydraulic damper (ASHD) is converted to interaction element (IE) of active interaction control (AIC). Systemic equations of motion, control law and control rulers of this proposed new AIC are studied in this research. A full-scale multiple degrees of freedom shaking table is tested toverify the energy dissipation of this proposed AIC, including test building without control, with passive control added involving various stiffness ratios and also with synchronic control added involving various stiffness ratios. Shock absorption of displacement can be up to 74–81% of that of the test structure with stiffness ratio = 2.3387 and 1.790 at 1st and 2nd floor under control of synchronous switch of this proposed AIC, respectively. No matter what the test structure added with various stiffeners at 1st and 2nd floor under synchronous control, test results of shock absorption ratio of acceleration show good seismic proof capability. In addition, base shear control effects of this proposed AIC method are higher than those of the test structure with various stiffeners added underpassive control. These results show that AIC with stiffeners for structural control provides the characteristics of a stabilized structure under excitation of near-fault earthquake with velocity impulse action

  1. Comparison of four methods to assess hydraulic conductivity

    Energy Technology Data Exchange (ETDEWEB)

    Benson, C.H. [Univ. of Wisconsin, Madison, WI (United States). Dept. of Civil and Environmental Engineering; Gunter, J.A. [Gunter (John A.), Round Rock, TX (United States); Boutwell, G.P. [STE, Inc., Baton Rouge, LA (United States); Trautwein, S.J. [Trautwein Soil Testing Equipment Co., Houston, TX (United States); Berzanskis, P.H. [Hoechst-Celanese, Inc., Pampa, TX (United States)

    1997-10-01

    A hydraulic conductivity assessment that was conducted on four test pads constructed to the same specifications with soil from the same source by four different contractors is described. The test pads had distinctly different field hydraulic conductivities, even though they were constructed with similar soil, to similar compaction conditions, and with similar machinery. Adequate hydration time was key in achieving low field hydraulic conductivity. More extensive processing was another factor responsible for low field hydraulic conductivity. Four different test methods were used to assess the hydraulic conductivity of each test pad: (1) sealed double-ring infiltrometers (SDRIs); (2) two-stage borehole permeameters; (3) laboratory hydraulic conductivity tests on large block specimens; and (4) laboratory hydraulic conductivity tests on small specimens collected in thin-wall sampling tubes. The tests were conducted independently by each of the writers. After the tests were completed, the results were submitted and compared. Analysis of the test results show that the three large-scale test methods generally yield similar hydraulic conductivities. For two of the test pads, however, the hydraulic conductivities of the specimens collected in sampling tubes were significantly lower than the field hydraulic conductivities. Both of these test pads had high field hydraulic conductivity. Thus, there is little value in using small specimens to assess field hydraulic conductivity.

  2. The Drift Burst Hypothesis

    DEFF Research Database (Denmark)

    Christensen, Kim; Oomen, Roel; Renò, Roberto

    The Drift Burst Hypothesis postulates the existence of short-lived locally explosive trends in the price paths of financial assets. The recent US equity and Treasury flash crashes can be viewed as two high profile manifestations of such dynamics, but we argue that drift bursts of varying magnitude......, currencies and commodities. We find that the majority of identified drift bursts are accompanied by strong price reversals and these can therefore be regarded as “flash crashes” that span brief periods of severe market disruption without any material longer term price impacts....

  3. Hydraulically Driven Grips For Hot Tensile Specimens

    Science.gov (United States)

    Bird, R. Keith; Johnson, George W.

    1994-01-01

    Pair of grips for tensile and compressive test specimens operate at temperatures up to 1,500 degrees F. Grips include wedges holding specimen inside furnace, where heated to uniform temperature. Hydraulic pistons drive wedges, causing them to exert clamping force. Hydraulic pistons and hydraulic fluid remain outside furnace, at room temperature. Cooling water flows through parts of grips to reduce heat transferred to external components. Advantages over older devices for gripping specimens in high-temperature tests; no need to drill holes in specimens, maintains constant gripping force on specimens, and heated to same temperature as that of specimen without risk of heating hydraulic fluid and acuator components.

  4. Argonne Liquid-Metal Advanced Burner Reactor : components and in-vessel system thermal-hydraulic research and testing experience - pathway forward.

    Energy Technology Data Exchange (ETDEWEB)

    Kasza, K.; Grandy, C.; Chang, Y.; Khalil, H.; Nuclear Engineering Division

    2007-06-30

    This white paper provides an overview and status report of the thermal-hydraulic nuclear research and development, both experimental and computational, conducted predominantly at Argonne National Laboratory. Argonne from the early 1970s through the early 1990s was the Department of Energy's (DOE's) lead lab for thermal-hydraulic development of Liquid Metal Reactors (LMRs). During the 1970s and into the mid-1980s, Argonne conducted thermal-hydraulic studies and experiments on individual reactor components supporting the Experimental Breeder Reactor-II (EBR-II), Fast Flux Test Facility (FFTF), and the Clinch River Breeder Reactor (CRBR). From the mid-1980s and into the early 1990s, Argonne conducted studies on phenomena related to forced- and natural-convection thermal buoyancy in complete in-vessel models of the General Electric (GE) Prototype Reactor Inherently Safe Module (PRISM) and Rockwell International (RI) Sodium Advanced Fast Reactor (SAFR). These two reactor initiatives involved Argonne working closely with U.S. industry and DOE. This paper describes the very important impact of thermal hydraulics dominated by thermal buoyancy forces on reactor global operation and on the behavior/performance of individual components during postulated off-normal accident events with low flow. Utilizing Argonne's LMR expertise and design knowledge is vital to the further development of safe, reliable, and high-performance LMRs. Argonne believes there remains an important need for continued research and development on thermal-hydraulic design in support of DOE's and the international community's renewed thrust for developing and demonstrating the Global Nuclear Energy Partnership (GNEP) reactor(s) and the associated Argonne Liquid Metal-Advanced Burner Reactor (LM-ABR). This white paper highlights that further understanding is needed regarding reactor design under coolant low-flow events. These safety-related events are associated with the transition

  5. GLAST Burst Monitor Trigger Classification Algorithm

    Science.gov (United States)

    Perrin, D. J.; Sidman, E. D.; Meegan, C. A.; Briggs, M. S.; Connaughton, V.

    2004-01-01

    The Gamma Ray Large Area Space Telescope (GLAST), currently set for launch in the first quarter of 2007, will consist of two instruments, the GLAST Burst Monitor (GBM) and the Large Area Telescope (LAT). One of the goals of the GBM is to identify and locate gamma-ray bursts using on-board software. The GLAST observatory can then be re-oriented to allow observations by the LAT. A Bayesian analysis will be used to distinguish gamma-ray bursts from other triggering events, such as solar flares, magnetospheric particle precipitation, soft gamma repeaters (SGRs), and Cygnus X-1 flaring. The trigger parameters used in the analysis are the burst celestial coordinates, angle from the Earth's horizon, spectral hardness, and the spacecraft geomagnetic latitude. The algorithm will be described and the results of testing will be presented.

  6. Thermal-Hydraulic Integral Effect Test with ATLAS for an Intermediate Break Loss of Coolant Accident at a Pressurizer Surge Line

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Kyoung Ho; Seok Cho; Park, Hyun Sik; Choi, Nam Hyun; Park, Yu Sun; Kim, Jong Rok; Bae, Byoung Uhn; Kim, Yeon Sik; Kim, Kyung Doo; Choi, Ki Yong; Song, Chul Hwa [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    The main objectives of this test were not only to provide physical insight into the system response of the APR1400 during the pressurizer surge line break accident but also to produce an integral effect test data to validate the SPACE code. In order to simulate a double-ended guillotine break of a pressurizer surge line in the APR1400, the IB-SUR-01R test was performed with ATLAS. The major thermal-hydraulic phenomena such as the system pressures, the collapsed water levels, and the break flow rate were presented and discussed. Despite the core was uncovered, no excursion in the cladding temperature was observed. The pressurizer surge line break can be classified as a hot leg break from a break location point of view. Compared with a cold leg break, coolability in the core may be better in case of a hot leg break due to the enhanced flow in the core region. This integral effect test data will be used to evaluate the prediction capability of existing safety analysis codes of the MARS and the RELAP5 as well as the SPACE code. Furthermore, this data can be utilized to identify any code deficiency for an IBLOCA simulation, especially for DVI-adapted plants. Redefinition of break size for design basis accident (DBA) based on risk information is being extensively investigated due to the potential for safety benefits and unnecessary burden reduction from current LBLOCA (large break loss of coolant accident)-based ECC (Emergency Core Cooling) Acceptance Criteria. As a transition break size (TBS), the rupture of medium-size pipe is considered to be more important than ever in risk-informed regulation (RIR)-relevant safety analysis. As plants age, are up-rated, and continue to seek improved operating efficiencies, the small break and intermediate break LOCA (IBLOCA) can become a concern. In particular, IBLOCA with DVI (Direct Vessel Injection) features will be addressed to support redefinition of a design-basis LOCA. With an aim of expanding code validation to address small

  7. Hydraulic Actuators with Autonomous Hydraulic Supply for the Mainline Aircrafts

    Directory of Open Access Journals (Sweden)

    I. S. Shumilov

    2014-01-01

    pipelines, as well as their increasing reliability. It is also possible, in addition, in addition to increase reliability of the remained pipelines, having applied the last developments, e.g. introduction of one-piece connections (thermo-mechanical ones, high-strength steels for pipelines with σв˃85 кг/мм 2 σ to increase control of residual assembly tension, and so on;- to eliminate essentially all the shortcomings of hydraulic actuators, which constrain their introduction in aircraft industry;- to simplify essentially steering drive structures and designs, which allow to apply the tried and tested components and principles;- to simplify essentially a solution for cooling of working liquid;- to simplify essentially a solution for the steering drive configuration in a zone of control vanes;- to simplify essentially a solution for meeting requirements for dynamic rigidity and dynamic sensitivity of hydraulic actuators;- to simplify essentially a solution for the aircraft fire safety, etc.

  8. 数控机床液压系统的可靠性验证试验方法%Reliability Validation Test for Hydraulic System of Numerical Control Machine

    Institute of Scientific and Technical Information of China (English)

    尹鹏程

    2011-01-01

    根据数控机床液压系统的主要故障模式,建立液压系统的可靠性模型,给出液压系统的可靠性特征量;基于可靠性试验的基本思路,提出数控机床液压系统的可靠性试验方法并给出示例,为数控机床液压系统的可靠性验证试验提供技术途径.%The functions, principles and main failure modes of hydraulic system of numerical control machine were introduced. A reliability model for this type of hydraulic system was established. Reliability characteristic parameters of this hydraulic system were given. Based on the idea of characteristic parameter measurement, the reliability test methods of the hydraulic system were put forward. An application example was given. The research work provides technology way for reliability validation test methods of the hydraulic system of numerical control machine.

  9. Pre-test analysis of an integral effect test facility for thermal-hydraulic similarities of 6 inches coldleg break and DVI injection line break using MARS-1D

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Tae Soon; Choi, Ki Yong; Park, Hyun Sik; Euh, Dong Jin; Baek, Won Pil [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2002-03-01

    A pre-test analysis of a small-break loss-of-coolant accident (SBLOCA, DVI Line break) has been performed for the integral effect test loop of Korea Atomic Energy Research Institute (Korea Atomic Energy Research Institute-ITL), the construction of which will be started soon. The Korea Atomic Energy Research Institute-ITL is a full-height and 1/310 volume-scaled test facility based on the design features of the APR1400 (Korean Next Generation Reactor). This paper briefly introduces the basic design features of the Korea Atomic Energy Research Institute-ITL and presents the results of pre-test analysis for a postulated cold leg SBLOCA and DVI line break. Based on the same control logics and accident scenarios, the similarity between the Korea Atomic Energy Research Institute-ITL and the prototype plant, APR1400, is evaluated by using the MARS code, which is a multi-dimensional best-estimate thermal hydraulic code being developed by Korea Atomic Energy Research Institute. It is found that the Korea Atomic Energy Research Institute-ITL and APR 1400 have similar thermal hydraulic responses against the analyzed SBLOCA and DVI Line break scenario. It is also verified that the volume scaling law, applied to the design of the Korea Atomic Energy Research Institute-ITL, gives a reasonable results to keep a similarity with APR1400. 11 refs., 19 figs., 3 tabs. (Author)

  10. CARR辐照压水堆小组件热工水力分析%Thermal-hydraulic Analysis of PWR Small Assembly for Irradiation Test of CARR

    Institute of Scientific and Technical Information of China (English)

    尹皓; 邹耀; 刘兴民

    2015-01-01

    T he thermal‐hydraulic behaviors of the PWR 4 × 4 small assembly tested in the high temperature and high pressure loop of China Advanced Research Reactor were analyzed .The CFD method was used to carry out 3D simulation of the model ,thus detailed thermal‐hydraulic parameters were obtained .Firstly ,the simplified model was simulated to give the 3D temperature and velocity distributions and analyze the heat transfer process .Then the whole scale small assembly model was simulated and the simulation results were compared with those of simplified rod bundle model .Its flow behavior was studied and flow mixing characteristics of the grids were analyzed ,and the mixing factor of the grid was calculated and can be used for further thermal‐hydraulic study .It is show n that the highest temperature of the fuel rod meets the design limit and the mixing effect of the grid is obvious .%分析压水堆4×4小组件在CARR高温高压回路中进行辐照考验时的热工水力问题。利用计算流体动力学(C FD )软件对其进行三维数值模拟,以获得详细的热工水力参数。首先,模拟简化的燃料棒束模型,得出三维温度与速度分布,并分析了传热过程。然后,模拟全尺寸小组件,与棒束模型所得的结果进行对比分析,着重研究其流动,并分析了格架的搅混特性,得出可应用于一维热工水力程序的搅混因子。结果表明,燃料棒最高温度可满足安全性要求,且格架的搅混作用明显。

  11. Fast Radio Bursts

    Indian Academy of Sciences (India)

    Akshaya Rane; Duncan Lorimer

    2017-09-01

    We summarize our current state of knowledge of fast radio bursts (FRBs) which were first discovered a decade ago. Following an introduction to radio transients in general, including pulsars and rotating radio transients, we discuss the discovery of FRBs. We then discuss FRB follow-up observations in the context of repeat bursts before moving on to review propagation effects on FRB signals, FRB progenitor models and an outlook on FRBs as potential cosmological tools.

  12. Numerical simulation of the direct contact condensation phenomena for PTS-related in single and combined-effect thermal hydraulic test facilities using TransAT CMFD code

    Energy Technology Data Exchange (ETDEWEB)

    Kadi, Rabah, E-mail: kadi.rkhaled@hotmail.com [Laboratory for Thermal-Hydraulics, Nuclear Research Center of Birine (Algeria); Aissani, Slimane [Hydrocarbons and Chemistry Faculty, University of Boumerdes (Algeria); Bouam, Abdellah [Laboratory for Thermal-Hydraulics, Nuclear Research Center of Birine (Algeria)

    2015-11-15

    Highlights: • TransAT CMFD code application to DCC phenomenon. • LEIS methodology to predict the condensing steam flow rate. • Validation of interfacial phase-change heat transfer and turbulence models. • Correction of damping function at the free surface region. • Numerical validation of previous models using LIM and KAERI & KAIST test facilities. - Abstract: The use of CFD for the industrial studies related to PTS, including DCC is already possible; improvements of the two-phase modeling capabilities have to be undertaken to qualify the codes for the simulation of such flows. The DCC in horizontally stratified flow regime constitutes very considerable challenge exercises for a computational fluid dynamics (CFD) simulation of the thermal hydraulics PTS phenomenon because the interplay between turbulence and interfacial heat and mass transfer problem. The main purpose of our study is to investigate numerically the DCC in horizontally stratified steam water flow in a 2D and 3D channel using TransAT CMFD code. The new methodology known as Large-Eddy & Interface (LEIS) have been implemented for treatment of turbulence combined with interface tracking ITM (level set approach). Among of the so-called ‘coarse-grained’ ITM's models, the modified original surface divergence has been chosen as well as the treatment of the turbulence by URANS and VLES. This contribution addressed on the validation of interfacial phase-change heat transfer and turbulence models with special correction of the damping function at the free surface for single and combined-effect thermal hydraulic studies for LIM and KAERI & KAIST test facilities. The LIES methodology was found to apply successfully to predict the condensing steam flow rate in the all cases of the LIM test case involving a Smooth to Wavy turbulent, concurrent stratified steam-water flow in a 2D channel. The CMFD TransAT code predicting capability is analyzed, comparing the liquid temperature and to much the

  13. Modelling of Hydraulic Robot

    DEFF Research Database (Denmark)

    Madsen, Henrik; Zhou, Jianjun; Hansen, Lars Henrik

    1997-01-01

    This paper describes a case study of identifying the physical model (or the grey box model) of a hydraulic test robot. The obtained model is intended to provide a basis for model-based control of the robot. The physical model is formulated in continuous time and is derived by application...... of the laws of physics on the system. The unknown (or uncertain) parameters are estimated with Maximum Likelihood (ML) parameter estimation. The identified model has been evaluated by comparing the measurements with simulation of the model. The identified model was much more capable of describing the dynamics...... of the system than the deterministic model....

  14. Phase analysis method for burst onset prediction

    Science.gov (United States)

    Stellino, Flavio; Mazzoni, Alberto; Storace, Marco

    2017-02-01

    The response of bursting neurons to fluctuating inputs is usually hard to predict, due to their strong nonlinearity. For the same reason, decoding the injected stimulus from the activity of a bursting neuron is generally difficult. In this paper we propose a method describing (for neuron models) a mechanism of phase coding relating the burst onsets with the phase profile of the input current. This relation suggests that burst onset may provide a way for postsynaptic neurons to track the input phase. Moreover, we define a method of phase decoding to solve the inverse problem and estimate the likelihood of burst onset given the input state. Both methods are presented here in a unified framework, describing a complete coding-decoding procedure. This procedure is tested by using different neuron models, stimulated with different inputs (stochastic, sinusoidal, up, and down states). The results obtained show the efficacy and broad range of application of the proposed methods. Possible applications range from the study of sensory information processing, in which phase-of-firing codes are known to play a crucial role, to clinical applications such as deep brain stimulation, helping to design stimuli in order to trigger or prevent neural bursting.

  15. A Test on Different Types of the Time Curve of Hardness Ratio of Gamma-Ray Bursts based on the Curvature Effect

    Institute of Scientific and Technical Information of China (English)

    Lan-Wei Jia

    2008-01-01

    We analyzed a sample of 66 gamma-ray bursts (GRBs) and statistically confirmed the prediction on the time curve of the hardness ratio of GRBs made by Qin et al. based on the curvature effect. In their analysis, GRB pulses are divided into three types according to the shape of their raw hardness ratio (RHR) time curves, defined as to include the background counts to the signal counts, so as to make use of counts within small time intervals. Of the three types, very hard sources exhibit a perfect pulse-like profile (type 1), hard bursts possess a pulse-like profile with a dip in the decay phase (type 2), and soft bursts show no pulse-like profile but have only a dipped profile (type 3). In terms of the conventional hardness ratio, type 3 sources are indeed generally softer than those of type 1 and type 2, in agreement with the prediction. We found that the minimum value of RHR is sensitive in distinguishing the different types. We propose that GRB pulses can be classified according to the minimum value of RHR and that the different type sources may be connected with different strengths of the shock or/and the magnetic field.

  16. Interplanetary Type IV Bursts

    CERN Document Server

    Hillaris, Alexander; Nindos, Alexander

    2016-01-01

    In this work we study the characteristics of moving type IV radio bursts which extend to the hectometric wavelengths (interplanetary type IV or type IV IP bursts) and their relationship with energetic phenomena on the Sun. Our dataset comprised 48 Interplanetary type IV bursts observed by the Wind/WAVES in the 13.825 MHz?20 KHz frequency range. The dynamic spec tra of the RSTN, DAM, ARTEMIS-IV, CULGOORA, Hiraiso and IZMIRAN Radio-spectrographs were used to track the evolution of the events in the low corona; these were supplemented with SXR ?ux recordings from GOES and CME data from LASCO. Positional information for the coronal bursts were obtained by the Nan\\c{c}ay radioheliograph (NRH). We examined the relationship of the type IV events with coronal radio bursts, CMEs and SXR ?ares. The majority of the events (45) were characterized as compact; their duration was on average 106 min. This type of events were, mostly, associated with M and X class ?ares (40 out of 45) and fast CMEs; 32 of these events had CME...

  17. Theoretical aspects for estimating anisotropic saturated hydraulic conductivity from in-well or direct-push probe injection tests in uniform media

    Science.gov (United States)

    Klammler, Harald; Layton, Leif; Nemer, Bassel; Hatfield, Kirk; Mohseni, Ana

    2017-06-01

    Hydraulic conductivity and its anisotropy are fundamental aquifer properties for groundwater flow and transport modeling. Current in-well or direct-push field measurement techniques allow for relatively quick determination of general conductivity profiles with depth. However, capabilities for identifying local scale conductivities in the horizontal and vertical directions are very limited. Here, we develop the theoretical basis for estimating horizontal and vertical conductivities from different types of steady-state single-well/probe injection tests under saturated conditions and in the absence of a well skin. We explore existing solutions and a recent semi-analytical solution approach to the flow problem under the assumption that the aquifer is locally homogeneous. The methods are based on the collection of an additional piece of information in the form of a second injection (or recirculation) test at a same location, or in the form of an additional head or flow observation along the well/probe. Results are represented in dimensionless charts for partial validation against approximate solutions and for practical application to test interpretation. The charts further allow for optimization of a test configuration to maximize sensitivity to anisotropy ratio. The two methods most sensitive to anisotropy are found to be (1) subsequent injection from a lateral screen and from the bottom of an otherwise cased borehole, and (2) single injection from a lateral screen with an additional head observation along the casing. Results may also be relevant for attributing consistent divergences in conductivity measurements from different testing methods applied at a same site or location to the potential effects of anisotropy. Some practical aspects are discussed and references are made to existing methods, which appear easily compatible with the proposed procedures.

  18. Determination and maintenance of DE minimis risk for migration of residual tritium (3H) from the 1969 Project Rulison nuclear test to nearby hydraulically fractured natural gas wells.

    Science.gov (United States)

    Daniels, Jeffrey I; Chapman, Jenny B

    2013-05-01

    The Project Rulison underground nuclear test was a proof-of-concept experiment that was conducted under the Plowshare Program in 1969 in the Williams Fork Formation of the Piceance Basin in west-central Colorado. Today, commercial production of natural gas is possible from low permeability, natural gas bearing formations like that of the Williams Fork Formation using modern hydraulic fracturing techniques. With natural gas exploration and production active in the Project Rulison area, this human health risk assessment was performed in order to add a human health perspective for site stewardship. Tritium (H) is the radionuclide of concern with respect to potential induced migration from the test cavity leading to subsequent exposure during gas-flaring activities. This analysis assumes gas flaring would occur for up to 30 d and produce atmospheric H activity concentrations either as low as 2.2 × 10 Bq m (6 × 10 pCi m) from the minimum detectable activity concentration in produced water or as high as 20.7 Bq m (560 pCi m), which equals the highest atmospheric measurement reported during gas-flaring operations conducted at the time of Project Rulison. The lifetime morbidity (fatal and nonfatal) cancer risks calculated for adults (residents and workers) and children (residents) from inhalation and dermal exposures to such activity concentrations are all below 1 × 10 and considered de minimis. The implications for monitoring production water for conforming health-protective, risk-based action levels also are examined.

  19. HYDRAULICS, LOUISA COUNTY, USA

    Data.gov (United States)

    Federal Emergency Management Agency, Department of Homeland Security — Hydraulic data include spatial datasets and data tables necessary for documenting the hydraulic analysis for estimating flood stages for a flood insurance study. It...

  20. Hydraulic Hybrid Vehicles

    Science.gov (United States)

    EPA and the United Parcel Service (UPS) have developed a hydraulic hybrid delivery vehicle to explore and demonstrate the environmental benefits of the hydraulic hybrid for urban pick-up and delivery fleets.

  1. A Burst to See

    Science.gov (United States)

    2008-04-01

    On 19 March, Nature was particularly generous and provided astronomers with the wealth of four gamma-ray bursts on the same day. But that was not all: one of them is the most luminous object ever observed in the Universe. Despite being located in a distant galaxy, billions of light years away, it was so bright that it could have been seen, for a brief while, with the unaided eye. ESO PR Photo 08a/08 ESO PR Photo 08a/08 The REM Telescope and TORTORA Camera Gamma-ray bursts (GRBs) are short flashes of energetic gamma-rays lasting from less than a second to several minutes. They release a tremendous quantity of energy in this short time making them the most powerful events since the Big Bang. It is now widely accepted that the majority of the gamma-ray bursts signal the explosion of very massive, highly evolved stars that collapse into black holes. Gamma-ray bursts, which are invisible to our eyes, are discovered by telescopes in space. After releasing their intense burst of high-energy radiation, they become detectable for a short while in the optical and in the near-infrared. This 'afterglow' fades very rapidly, making detailed analysis possible for only a few hours after the gamma-ray detection. This analysis is important in particular in order to determine the GRB's distance and, hence, intrinsic brightness. The gamma-ray burst GRB 080319B was detected by the NASA/STFC/ASI Swift satellite. "It was so bright that it almost blinded the Swift instruments for a while," says Guido Chincarini, Italian principal investigator of the mission. A bright optical counterpart was soon identified in the Boötes Constellation (the "Bear Driver" or "Herdsman"). A host of ground-based telescopes reacted promptly to study this new object in the sky. In particular, the optical emission was detected by a few wide-field cameras on telescopes that constantly monitor a large fraction of the sky, including the TORTORA camera in symbiosis with the 0.6-m REM telescope located at La Silla

  2. Generation of burst time plans for the Intelsat TDMA system

    Science.gov (United States)

    Trusty, P. A.; King, C. A.; Roach, P. W.

    In the Intelsat time-division multiple-access (TDMA) system, the burst time plan (BTP) contains the assignments of traffic and reference bursts, common acquisition windows, and test slots to time slots within the TDMA frame for a given network. Generation of the BTP involves the processes of sub-burst formation, burst formation, reference burst assignments, and burst scheduling. BTP information is transferred to the individual reference and traffic stations in the form of a master time plan (MTP) and a condensed time plan (CTP). This paper describes algorithms which have been developed for each of the BTP generation processes, as well as those algorithms and procedures used to generate the MTPs and CTPs. A software system which implements these algorithms is also discussed.

  3. Benchmark Simulations of the Thermal-Hydraulic Responses during EBR-II Inherent Safety Tests using SAM

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Rui; Sumner, Tyler S.

    2016-04-17

    An advanced system analysis tool SAM is being developed for fast-running, improved-fidelity, and whole-plant transient analyses at Argonne National Laboratory under DOE-NE’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. As an important part of code development, companion validation activities are being conducted to ensure the performance and validity of the SAM code. This paper presents the benchmark simulations of two EBR-II tests, SHRT-45R and BOP-302R, whose data are available through the support of DOE-NE’s Advanced Reactor Technology (ART) program. The code predictions of major primary coolant system parameter are compared with the test results. Additionally, the SAS4A/SASSYS-1 code simulation results are also included for a code-to-code comparison.

  4. Multi-Purpose Thermal Hydraulic Loop: Advanced Reactor Technology Integral System Test (ARTIST) Facility for Support of Advanced Reactor Technologies

    Energy Technology Data Exchange (ETDEWEB)

    James E. O' Brien; Piyush Sabharwall; SuJong Yoon

    2001-11-01

    Effective and robust high temperature heat transfer systems are fundamental to the successful deployment of advanced reactors for both power generation and non-electric applications. Plant designs often include an intermediate heat transfer loop (IHTL) with heat exchangers at either end to deliver thermal energy to the application while providing isolation of the primary reactor system. In order to address technical feasibility concerns and challenges a new high-temperature multi-fluid, multi-loop test facility “Advanced Reactor Technology Integral System Test facility” (ARTIST) is under development at the Idaho National Laboratory. The facility will include three flow loops: high-temperature helium, molten salt, and steam/water. Details of some of the design aspects and challenges of this facility, which is currently in the conceptual design phase, are discussed

  5. The steady-state dipole-flow test for characterization of hydraulic conductivity statistics in a highly permeable aquifer: Horkheimer Insel site, Germany.

    Science.gov (United States)

    Zlotnik, V A; Zurbuchen, B R; Ptak, T

    2001-01-01

    Over the last decade the dipole-flow test (DFT) evolved from the general idea of using recirculatory flow to evaluate aquifer properties, to the development of prototype instrumentation and feasibility studies, to a reliable tool for characterization of aquifer heterogeneity. The DFT involves the interpretation of head in recirculatory flow between injection and extraction sections (chambers) in a single well isolated from each other by a multipacker system. In this study, the steady-state dipole flow test (DFT) has been used to characterize the statistics of horizontal hydraulic conductivity (Kr) of the highly permeable, heterogeneous, and thin aquifer at the Horkheimer Insel site, Germany. In previous studies, Kr estimates were based on the steady-state head difference between chambers. A new by-chamber interpretation is proposed that is based on drawdown within each individual chamber. This interpretation yields more detailed information on structure of heterogeneity of the aquifer without introducing complexity into the analysis. The DFT results indicate that Kr ranges from 49 to 6000 m/day (mean ln Kr [(m/s)] approximately -4, and variance of ln Kr [(m/s)] approximately 1-2). Descriptive statistics from the DFT compare well with those from previous field and laboratory tests (pumping, borehole flowmeter, and permeameter tests and grain-size analysis) at this site. It is shown that the role of confining boundaries in the DFT interpretation is negligible even in this case of a thin (< 4 m thick) aquifer. This study demonstrates the flexibility of the DFT and expands the potential application of this method to a wide range of hydrogeologic settings.

  6. On the use of the MISTRA coupled effect test facility for the validation of containment thermal-hydraulics codes

    Energy Technology Data Exchange (ETDEWEB)

    Studer, E.; Dabbene, F.; Magnaud, J. P.; Blumenfeld, L.; Quillico, J. J.; Paillere, H. [CEA Saclay, Gif-sur-Yvette (France)

    2003-07-01

    Twenty four years after the Three Mile Island Accident, Hydrogen risk remains a safety issue for current and future Pressurized Water Reactors (PWR). The formation of a combustible gas mixture in the complex geometry of a reactor containment depends on the understanding of hydrogen production, complex 3D flow due to gas/steam injection, natural convection, heat transfer by condensation on walls and effect of mitigation devices. Lumped parameter safety codes mainly developed for full containment analysis are not able to accurately predict the local gas mixing within the containment. 3D CFD codes are required but a thorough validation process on well-instrumented experimental data is necessary before they can be used with a high degree of confidence. The MISTRA coupled effect test facility has been recently built at CEA to fulfill these objectives: numerous measurement points in the gaseous volume (temperature and gas concentration) and the use of Laser technology (L.D.V. and P.I.V.) provide suitable experimental data for code validation. The in-house CEA-IRSN CAST3M/TONUS code is developed and validated against experimental data provided by this facility. Some of these tests have been proposed to the international community for code benchmarking (MICOCO benchmark and OECD/ISP47 exercise). Finally, extrapolation to global containment scale requires the validation of the code on more complex flow patterns and a detailed investigation of scaling effects. These two items will be the guidelines of future MISTRA tests.

  7. Experiments on Performance Sensitivity of SMART PRHRS using the High Temperature/High Pressure Thermal-Hydraulic Test Facility (VISTA)

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyun Sik; Choi, Ki Yong; Cho, Seok; Lee, Sung Jae; Choi, Nam Hyun; Min, Kyong Ho; Song, Chul Hwa; Park, Chun Kyong; Chung, Moon Ki

    2005-07-15

    The VISTA (Experimental Verification by Integral Simulation of Transients and Accidents) is an experimental facility to verify the performance and safety issues of the SMART-P (Pilot plant of the System-integrated Modular Advanced Reactor). The basic design of the SMART-P has been completed by KAERI. The present report describes the experimental results on the overall performance sensitivity of SMART PRHRS. During the reference test a stable flow occurs in a natural circulation loop which is composed of a steam generator secondary side, a secondary system, and a PRHRS, and it is ascertained by a repetition test. When the bypass valves of PRHRS are operated earlier than the isolation valves of secondary system, the primary system is effectively cooled but the inventory of PRHRS compensation tank is drained earlier. When the bypass valves of PRHRS are operated later than the isolation valves of secondary system, the primary system is not cooled. As the initial level of compensation tank is lowered to 16% of the full level, the steady natural circulation stops around 500 seconds. When the initial pressure of PRHRS is at 0.1 MPa, the natural circulation is not performed properly. When they are 2.5 and 3.5 MPa, it shows better performance than the reference test. Also when the isolation valve connecting the compensation tank is operated simultaneously with the PRHRS isolation valves, the primary system is more efficiently cooled but the inventory of PRHRS compensation tank is drained earlier.

  8. The Glast Burst Monitor

    Science.gov (United States)

    Meegan, Charles

    2000-01-01

    The Gamma-Ray Large Area Space Telescope (GLAST) will include a secondary instrument to augment the observatory's capabilities for GRB studies. The GLAST Burst Monitor (GBK is a collaboration between Marshall Space Flight Center, the University of Huntsville, Alabama, and the Max Plank Institute for Extraterrestrial Physics. The purpose of the GBM is to extend energy coverage below the main instrument's lower limit of about 20 MeV, and to provide an on-board burst trigger and approximate location. The instrument consists of twelve NaI detectors and two BGO detectors. This combination provides energy coverage from a few keV up to about 30 MeV.

  9. Interplanetary Type IV Bursts

    Science.gov (United States)

    Hillaris, A.; Bouratzis, C.; Nindos, A.

    2016-08-01

    We study the characteristics of moving type IV radio bursts that extend to hectometric wavelengths (interplanetary type IV or type {IV}_{{IP}} bursts) and their relationship with energetic phenomena on the Sun. Our dataset comprises 48 interplanetary type IV bursts observed with the Radio and Plasma Wave Investigation (WAVES) instrument onboard Wind in the 13.825 MHz - 20 kHz frequency range. The dynamic spectra of the Radio Solar Telescope Network (RSTN), the Nançay Decametric Array (DAM), the Appareil de Routine pour le Traitement et l' Enregistrement Magnetique de l' Information Spectral (ARTEMIS-IV), the Culgoora, Hiraso, and the Institute of Terrestrial Magnetism, Ionosphere and Radio Wave Propagation (IZMIRAN) Radio Spectrographs were used to track the evolution of the events in the low corona. These were supplemented with soft X-ray (SXR) flux-measurements from the Geostationary Operational Environmental Satellite (GOES) and coronal mass ejections (CME) data from the Large Angle and Spectroscopic Coronagraph (LASCO) onboard the Solar and Heliospheric Observatory (SOHO). Positional information of the coronal bursts was obtained by the Nançay Radioheliograph (NRH). We examined the relationship of the type IV events with coronal radio bursts, CMEs, and SXR flares. The majority of the events (45) were characterized as compact, their duration was on average 106 minutes. This type of events was, mostly, associated with M- and X-class flares (40 out of 45) and fast CMEs, 32 of these events had CMEs faster than 1000 km s^{-1}. Furthermore, in 43 compact events the CME was possibly subjected to reduced aerodynamic drag as it was propagating in the wake of a previous CME. A minority (three) of long-lived type {IV}_{{IP}} bursts was detected, with durations from 960 minutes to 115 hours. These events are referred to as extended or long duration and appear to replenish their energetic electron content, possibly from electrons escaping from the corresponding coronal

  10. Plan for proposed aquifer hydraulic testing and groundwater sampling at Everest, Kansas, in January-February 2006.

    Energy Technology Data Exchange (ETDEWEB)

    LaFreniere, L. M.; Environmental Science Division

    2006-01-31

    On September 8-9, 2005, representatives of the Kansas Department of Health and Environment (KDHE), the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA), and Argonne National Laboratory met at the KDHE's offices in Topeka to review the status of the CCC/USDA's environmental activities in Kansas. A key CCC/USDA goal for this meeting was to obtain KDHE input on the selection of possible remedial approaches to be examined as part of the Corrective Action Study (CAS) for this site. As a result of the September meeting, the KDHE recommended several additional activities for the Everest site, to further assist in selecting and evaluating remedial alternatives for the CAS. The requested actions included the following: (1) Construction of several additional interpretive cross sections to improve the depiction of the hydrogeologic characteristics affecting groundwater and contaminant movement along the apparent main plume migration pathway to the north-northwest of the former CCC/USDA facility, and in the vicinity of the Nigh property. (2) Identification of potential locations for several additional monitoring wells, to better constrain the apparent western and northwestern margins of the existing groundwater plume. (3) Development of technical recommendations for a stepwise pumping study of the Everest aquifer unit in the area near and to the north of the Nigh property. On October 21, 2005, Argonne issued a brief Cross Section Analysis (Argonne 2006a) addressing these concerns, on behalf of the CCC/USDA. This report includes the following: (1) Preliminary recommendations for the siting of three new monitoring wells, at locations identified by the KDHE. Argonne also suggested, however, that the installation and sampling of these wells be deferred until after completion of the CAS evaluation. (2) A proposed strategy for testing of the Everest aquifer unit near the Nigh property, involving initial test pumping of the former Nigh domestic

  11. Can we identify lensed gamma-ray bursts?

    Science.gov (United States)

    Nowak, Michael A.; Grossman, Scott A.

    1994-01-01

    A gravitationally lensed gamma-ray burst (GRB) would appear as multiple bursts with identical light curves, separated in time and differing only by the scaling of their amplitudes. In reality, the detected bursts will be noisy, and therefore they may be difficult to identify as lensed images. Furthermore, faint, intrinsically similar, yet distinct light curves may be falsely identified as lensing events. In this paper we develop two statistical tests to distinguish noisy burst light curves. We use Fourier analysis techniques to analyze the signals for both intrinsic variability and variability due to noise. We are able to determine the noise level, and we compare the bursts only at frequency channels that are signal dominated. Utilizing these methods, we are able to make quantitative statements about whether two bursts are distinct. We apply these statistics to scaled versions of two subbursts of GRB 910503 -- subbursts previously investigated by Wambsganss using a different statistical test. We find that our methods are able to distinguish these bursts at slightly smaller amplitudes than those at which Wambsganss's method succeeds. We then apply our techniques to 'candidate' lensing events taken from the Burst and Transient Source Experiment (BATSE) catalog, and we find that nearly all of them, except for the very shortest ones (durations approx. less than 3 sec), are distinguishable. We therefore expect that a majority of bursts will be distinguishable from one another.

  12. A Repeating Fast Radio Burst

    CERN Document Server

    Spitler, L G; Hessels, J W T; Bogdanov, S; Brazier, A; Camilo, F; Chatterjee, S; Cordes, J M; Crawford, F; Deneva, J; Ferdman, R D; Freire, P C C; Kaspi, V M; Lazarus, P; Lynch, R; Madsen, E C; McLaughlin, M A; Patel, C; Ransom, S M; Seymour, A; Stairs, I H; Stappers, B W; van Leeuwen, J; Zhu, W W

    2016-01-01

    Fast Radio Bursts are millisecond-duration astronomical radio pulses of unknown physical origin that appear to come from extragalactic distances. Previous follow-up observations have failed to find additional bursts at the same dispersion measures (i.e. integrated column density of free electrons between source and telescope) and sky position as the original detections. The apparent non-repeating nature of the fast radio bursts has led several authors to hypothesise that they originate in cataclysmic astrophysical events. Here we report the detection of ten additional bursts from the direction of FRB121102, using the 305-m Arecibo telescope. These new bursts have dispersion measures and sky positions consistent with the original burst. This unambiguously identifies FRB121102 as repeating and demonstrates that its source survives the energetic events that cause the bursts. Additionally, the bursts from FRB121102 show a wide range of spectral shapes that appear to be predominantly intrinsic to the source and wh...

  13. Hydraulic contacts identification in the aquifers of limestone ridges: tracer tests in the Montelago pilot area (Central Apennines

    Directory of Open Access Journals (Sweden)

    Alberto Tazioli

    2016-08-01

    Full Text Available The investigated area, located in the inner part of the Marche region (central Italy and belonging to the carbonate Umbria- Marche ridges in the central Apennines, is characterised by very complex geo-structural setting and widespread karst phenomena that make difficult the definition of the relation among the aquifers basing only on the hydrogeological survey. Hence, the presence of different flowpaths among aquifers of the Umbria-Marche hydrostratigraphic sequence and of tectonic contacts among the different structures is verified using tracer tests. In particular, the tests showed that the Calcare Massiccio and the Maiolica aquifers are connected under certain tectonic conditions. A new tracer given by a single stranded DNA molecule and traditional fluorescent dyes have been injected into the Montelago sinkhole in different periods (during the recharge and during the discharge and recovered in several points along the expected hydrogeological basin, using either manual and automatic sampling. Fluorescent traps were positioned in creeks, rivers and springs. The DNA molecule is useful to trace surface water and groundwater, is detectable even at very low concentrations, no significant change in water density and viscosity can be observed and its use is not dangerous for the environment. The results stress the suitability of DNA as hydrogeological tracer, capable to identify connections among aquifers and study different flowpaths even in high flow conditions when traditional tracers are more and more diluted. Moreover, fluorescein tracer allowed for the transport parameter determination, giving mean velocities ranging from 100 to 3000 m/day and mean residence time from some tens to hundreds of hours, and determining the aquifer volumes.

  14. Development of the Hydraulic System Performance Test Bench for the Intelligent Drilling Tools%智能钻井工具液压系统性能测试台的研制∗

    Institute of Scientific and Technical Information of China (English)

    白大鹏; 李绍辉; 马哲; 王海岩; 黄峰

    2016-01-01

    为节省智能钻井工具液压系统的维修和测试时间,提高智能钻井工具技术服务质量,研制了用于检测智能钻井工具液压系统性能的测试台。该测试台根据智能钻井工具液压系统工作原理而设计,选用BH系列智能钻井工具中的测量和控制电路作为测试台的测量和控制电路。测试台通过模拟液压系统的工作过程,对各液压部件进行性能检测和故障排查。现场试验结果表明:测试台可对液压系统各部件的性能单独进行测试,测试结果能准确反映其工作性能和故障原因。所得结论对提高工具的组装和测试效率具有重要意义。%In order to reduce the repair and test time for the hydraulic system of intelligent drilling tool and to improve the quality of technical services, a test bench which could simulate the hydraulic system of the intelligent drilling tool was developed�The test bench was designed based on the operating principle of the hydraulic system for the intelligent drilling tool and uses the measuring and control circuit in BH series intelligent drilling tool as its own measuring and control circuit�By simulating the working process of the hydraulic system, the test bench makes functional experiment and troubleshooting of each hydraulic part�The result showed that the test bench could test each part in the hydraulic system separately and the result of experiment could accurately indicate its working per⁃formance and fault reason�Therefore, the conclusion obtained is of important significance to improvement of tool as⁃sembly and test efficiency.

  15. Hydraulic power take-off for wave energy systems

    DEFF Research Database (Denmark)

    Christensen, Georg Kronborg

    2001-01-01

    Investigation and laboratory experiments with a hydraulic power conversion system for converting forces from a 2.5m diamter float to extract energy from seawaves. The test rig consists of a hydraulic wave simulator and a hydraulic point absorber. The absorber converts the incomming forces...

  16. 3D thermal hydraulic simulation of the hot channel of a typical material testing reactor under normal operation conditions

    Energy Technology Data Exchange (ETDEWEB)

    El-Morshedy, Salah El-Din; Salama, Amgad [Atomic Energy Authority, Cairo (Egypt). Reactors Dept.

    2010-09-15

    The hot channel in a typical Material Testing Reactor (MTR) is subjected to 3D simulation. Because of the existence of similarity planes, only a quarter of the hot channel including meat thickness, clad, and coolant channel is considered for CFD analysis using the FLUENT code. For the simulation, steady state normal operation regime at the reactor nominal power is assumed. In order to build confidence in our modeling approach, the results obtained in this work are compared with those obtained from the one-dimensional simulation code, MTRTHA. That is, modified variables were generated in order to match those obtained by MTRTHA and to allow comparisons. Quite good agreement is generally observed, however, the maximum clad surface temperature predicted by the 3D calculations, located at the clad mid-width, is higher than the 1D prediction by about 8 C but still below the onset of subcooled boiling by adequate safety margin. The results show quite interesting 3D patterns in both the flow field and the heat transfer. Temperature profiles, velocity profiles and contours are all presented to highlight the essential 3D features of this system. (orig.)

  17. Serial Charging Test on High Capacity Li-Ion Cells for the Orbiter Advanced Hydraulic Power System

    Science.gov (United States)

    Jeevarajan, Judith A.; Irlbeck, Brad

    2006-01-01

    Although it looks like module level voltage drives the cutoff for charge, the actual cutoff is due to unbalanced cell voltages that drive the module voltage up. Individual cell voltage drives the cutoff for discharge Low resistance cells are the first to reach the low-voltage cutoff Cell-to-Cell voltage differences are generally small and show similar trends for each cycle Increase for a distinct window during charge and at the end of discharge Increase in max to min cell voltage difference with time/cycles Decrease in max to min cell voltage difference during high current pulses with time/cycles Individual cell voltage trends (with respect to other cells) are very repeatable from cycle to cycle, although voltage slowly degrades with time/cycles (resistance growth) Much more difference observed near end of discharge Little change in order of cell voltage (cell with highest voltage to cell with lowest voltage) Temp sensor on the side of cell (between 2 cells) shows much greater rise during discharge than for single cell tests (18 C vs 5 C) Conclusion: Serial Charging of this string of cells is feasible as it has only a minor impact on useful capacity

  18. The Cosmic Gamma-Ray Bursts

    CERN Document Server

    Djorgovski, S G; Kulkarni, S R; Sari, R; Bloom, J S; Galama, T J; Harrison, F A; Price, P A; Fox, D; Reichart, D; Yost, S; Berger, E; Diercks, A H; Goodrich, R; Chaffee, F H

    2001-01-01

    Cosmic gamma-ray bursts are one of the great frontiers of astrophysics today. They are a playground of relativists and observers alike. They may teach us about the death of stars and the birth of black holes, the physics in extreme conditions, and help us probe star formation in the distant and obscured universe. In this review we summarise some of the remarkable progress in this field over the past few years. While the nature of the GRB progenitors is still unsettled, it now appears likely that at least some bursts originate in explosions of very massive stars, or at least occur in or near the regions of massive star formation. The physics of the burst afterglows is reasonably well understood, and has been tested and confirmed very well by the observations. Bursts are found to be beamed, but with a broad range of jet opening angles; the mean gamma-ray energies after the beaming corrections are ~ 10^51 erg. Bursts are associated with faint ~ 25 mag) galaxies at cosmological redshifts, with ~ 1. The host gal...

  19. 浅谈复合式高低压缸液力端在四缸试压泵中的应用%On Application of Compound High and Low Pressure Cylinder Hydraulic Side in the Four Cylinder Hydraulic Test Pump

    Institute of Scientific and Technical Information of China (English)

    蒋金泉

    2014-01-01

    复合式高低压缸液力端,是将泵体上两平行的复合缸分别与一根大小直径的阶梯柱塞配合,形成大流量低压缸和小流量高压缸,解决了现有四缸往复式试压泵存在的问题。%Compound high and low pressure cylinder hydraulic side means to match the two parallel composite cylinder on the pump body, respectively with ladder plunger with big diameter on one side and small diameter on the other side, forming large flow low pressure cylinder and small flow high pressure cylinder, which has solved the existing problems of four cylinder reciprocating hydraulic test pump.

  20. The Double Firing Burst

    Science.gov (United States)

    2008-09-01

    Astronomers from around the world combined data from ground- and space-based telescopes to paint a detailed portrait of the brightest explosion ever seen. The observations reveal that the jets of the gamma-ray burst called GRB 080319B were aimed almost directly at the Earth. Uncovering the disc ESO PR Photo 28/08 A Gamma-Ray Burst with Two Jets Read more on this illuminating blast in the additional story. GRB 080319B was so intense that, despite happening halfway across the Universe, it could have been seen briefly with the unaided eye (ESO 08/08). In a paper to appear in the 11 September issue of Nature, Judith Racusin of Penn State University, Pennsylvania (USA), and a team of 92 co-authors report observations across the electromagnetic spectrum that began 30 minutes before the explosion and followed it for months afterwards. "We conclude that the burst's extraordinary brightness arose from a jet that shot material almost directly towards Earth at almost the speed of light - the difference is only 1 part in 20 000," says Guido Chincarini, a member of the team. Gamma-ray bursts are the Universe's most luminous explosions. Most occur when massive stars run out of fuel. As a star collapses, it creates a black hole or neutron star that, through processes not fully understood, drives powerful gas jets outward. As the jets shoot into space, they strike gas previously shed by the star and heat it, thereby generating bright afterglows. The team believes the jet directed toward Earth contained an ultra-fast component just 0.4 degrees across (this is slightly smaller than the apparent size of the Full Moon). This jet is contained within another slightly less energetic jet about 20 times wider. The broad component is more typical of other bursts. "Perhaps every gamma-ray burst has a narrow jet, but astronomers miss it most of the time," says team member Stefano Covino. "We happened to view this monster down the barrel of the very narrow and energetic jet, and the chance for

  1. Fast Radio Burst/Gamma-Ray Burst Cosmography

    Science.gov (United States)

    Gao, He; Li, Zhuo; Zhang, Bing

    2014-06-01

    Recently, both theoretical arguments and observational evidence suggested that a small fraction of fast radio bursts (FRBs) could be associated with gamma-ray bursts (GRBs). If such FRB/GRB association systems are commonly detected in the future, the combination of dispersion measures (DM) derived from FRBs and redshifts derived from GRBs makes these systems a plausible tool to conduct cosmography. We quantify uncertainties in deriving the redshift-dependent DM_{IGM} as a function of z and test how well dark energy models can be constrained with Monte Carlo simulations. We show that with several tens of FRB/GRB systems potentially detected in a decade or so, one may reach reasonable constraints on wCDM models. When combined with Type Ia supernova (SN Ia) data, unprecedented constraints on the dark energy equation of state may be achieved, thanks to the prospects of detecting FRB/GRB systems at relatively high redshifts. The ratio between the mean value \\lt {DM_IGM} (z)\\gt and luminosity distance (D L(z)) is insensitive to dark energy models. This gives the prospect of applying SN Ia data to calibrate \\lt {DM_IGM} (z)\\gt using a relatively small sample of FRB/GRB systems, allowing a reliable constraint on the baryon inhomogeneity distribution as a function of redshift. The methodology developed in this paper can also be applied if the FRB redshifts can be measured by other means. Some caveats of putting this method into practice are also discussed.

  2. Fast radio burst/gamma-ray burst cosmography

    Energy Technology Data Exchange (ETDEWEB)

    Gao, He; Zhang, Bing [Department of Physics and Astronomy, University of Nevada Las Vegas, NV 89154 (United States); Li, Zhuo, E-mail: gaohe@physics.unlv.edu, E-mail: zhang@physics.unlv.edu, E-mail: zhuo.li@pku.edu.cn [Department of Astronomy, School of Physics, Peking University, Beijing 100871 (China)

    2014-06-20

    Recently, both theoretical arguments and observational evidence suggested that a small fraction of fast radio bursts (FRBs) could be associated with gamma-ray bursts (GRBs). If such FRB/GRB association systems are commonly detected in the future, the combination of dispersion measures (DM) derived from FRBs and redshifts derived from GRBs makes these systems a plausible tool to conduct cosmography. We quantify uncertainties in deriving the redshift-dependent DM{sub IGM} as a function of z and test how well dark energy models can be constrained with Monte Carlo simulations. We show that with several tens of FRB/GRB systems potentially detected in a decade or so, one may reach reasonable constraints on wCDM models. When combined with Type Ia supernova (SN Ia) data, unprecedented constraints on the dark energy equation of state may be achieved, thanks to the prospects of detecting FRB/GRB systems at relatively high redshifts. The ratio between the mean value and luminosity distance (D {sub L}(z)) is insensitive to dark energy models. This gives the prospect of applying SN Ia data to calibrate using a relatively small sample of FRB/GRB systems, allowing a reliable constraint on the baryon inhomogeneity distribution as a function of redshift. The methodology developed in this paper can also be applied if the FRB redshifts can be measured by other means. Some caveats of putting this method into practice are also discussed.

  3. Transputer Control of Hydraulic Actuators and Robots

    DEFF Research Database (Denmark)

    Conrad, Finn

    1996-01-01

    Results from a Danish mechatronics research program entitled IMCIA - Intelligent Control and Intelligent Actuators. The objective is development of intelligent actuators for intelligent motion control. A mechatronics test facility with a transputer controlled hydraulic robot suiteable for real...

  4. Transputer Control of Hydraulic Actuators and Robots

    DEFF Research Database (Denmark)

    Conrad, Finn

    1996-01-01

    Results from a Danish mechatronics research program entitled IMCIA - Intelligent Control and Intelligent Actuators. The objective is development of intelligent actuators for intelligent motion control. A mechatronics test facility with a transputer controlled hydraulic robot suiteable for real...

  5. Fire Resistant Aircraft Hydraulic System.

    Science.gov (United States)

    1982-07-01

    and compounds based on new experimental elastomers as well as most commercially available elastomers were screened in seeking seals that were both...for hydraulic component testing. All of the available E6.5 stock was purchased for the screening tests. However, DuPont stated that other homologs of...with the lubricity and anti-wear additive olyvan A (molybdenum oxysulphide dithiocarbamate ) added in the quantity of less than one percent by weight

  6. Mechatronic Hydraulic Drive with Regulator, Based on Artificial Neural Network

    Science.gov (United States)

    Burennikov, Y.; Kozlov, L.; Pyliavets, V.; Piontkevych, O.

    2017-06-01

    Mechatronic hydraulic drives, based on variable pump, proportional hydraulics and controllers find wide application in technological machines and testing equipment. Mechatronic hydraulic drives provide necessary parameters of actuating elements motion with the possibility of their correction in case of external loads change. This enables to improve the quality of working operations, increase the capacity of machines. The scheme of mechatronic hydraulic drive, based on the pump, hydraulic cylinder, proportional valve with electrohydraulic control and programmable controller is suggested. Algorithm for the control of mechatronic hydraulic drive to provide necessary pressure change law in hydraulic cylinder is developed. For the realization of control algorithm in the controller artificial neural networks are used. Mathematical model of mechatronic hydraulic drive, enabling to create the training base for adjustment of artificial neural networks of the regulator is developed.

  7. Testing the External Shock Model of Gamma-Ray Bursts using the Late-Time Simultaneous Optical and X-ray Afterglows

    CERN Document Server

    Urata, Yuji; Sakamoto, Takanori; Huang, Kuiyun; Zheng, Weikang; Sato, Goro; Aoki, Tsutomu; Deng, Jinsong; Ioka, Kunihito; Ip, WingHuen; Kawabata, Koji S; Lee, YiHsi; Liping, Xin; Mito, Hiroyuki; Miyata, Takashi; Nakada, Yoshikazu; Ohsugi, Takashi; Qiu, Yulei; Soyano, Takao; Tarusawa, Kenichi; Tashiro, Makoto; Uemura, Makoto; Wei, Jianyan; Yamashita, Takuya

    2007-01-01

    We study the ``normal'' decay phase of the X-ray afterglows of gamma-ray bursts (GRBs), which follows the shallow decay phase, using the events simultaneously observed in the R-band. The classical external shock model, in which neither the delayed energy injection nor time-dependency of shock micro-physics is considered, shows that the decay indices of the X-ray and R-band light curves, $\\alpha_{\\rm X}$ and $\\alpha_{\\rm O}$, obey a certain relation, and that in particular, $\\alpha_{\\rm O}-\\alpha_{\\rm X}$ should be larger than -1/4. For our selected 14 samples, we have found that 7 events violate the limit taking into account 1$\\sigma$ error, so that a fraction of events are outliers of the classical external shock model at the ``normal'' decay phase.

  8. A method for mapping topsoil field-saturated hydraulic conductivity in the Cévennes-Vivarais region using infiltration tests conducted with different techniques

    Science.gov (United States)

    Braud, Isabelle; Desprats, Jean-François; Ayral, Pierre-Alain; Bouvier, Christophe; Vandervaere, Jean-Pierre

    2017-04-01

    Topsoil field-saturated hydraulic conductivity, Kfs, is a parameter that controls the partition of rainfall between infiltration and runoff. It is a key parameter in most distributed hydrological models. However, there is a mismatch between the scale of local in situ measurements and the scale at which the parameter is required in models. Therefore it is necessary to design methods to regionally map this parameter at the model scale. The paper propose a method for mapping Kfs in the Cévennes-Vivarais region, south-east France, using more easily available GIS data: geology and land cover. The mapping is based on a data set gathering infiltration tests performed in the area or close to it for more than ten years. The data set is composed of infiltration tests performed using various techniques: Guelph permeameter, double ring and single ring infiltration tests, infiltrometers with multiple suctions. The different methods lead to different orders of magnitude for Kfs rendering the pooling of all the data challenging. Therefore, a method is first proposed to pool the data from the different infiltration methods, leading to a homogenized set of Kfs, based on an equivalent double ring/tension disk infiltration value. Statistical tests showed significant differences in distributions among different geologies and land covers. Thus those variables were retained as proxy for mapping Kfs at the regional scale. This map was compared to a map based on the Rawls and Brakensiek (RB) pedo-transfer function (Manus et al., 2009, Vannier et al., 2016), showing very different patterns between both maps. In addition, RB values did not fit observed values at the plot scale, highlighting that soil texture only is not a good predictor of Kfs. References Manus, C., Anquetin, S., Braud, I., Vandervaere, J.P., Viallet, P., Creutin, J.D., Gaume, E., 2009. A modelling approach to assess the hydrological response of small Mediterranean catchments to the variability of soil characteristics in a

  9. Hydraulic characterization of " Furcraea andina

    Science.gov (United States)

    Rivera-Velasquez, M. F.; Fallico, C.; Molinari, A.; Santillan, P.; Salazar, M.

    2012-04-01

    The present level of pollution, increasingly involving groundwaters, constitutes a serious risk for environment and human health. Therefore the remediation of saturated and unsaturated soils, removing pollutant materials through innovative and economic bio-remediation techniques is more frequently required. Recent studies on natural fiber development have shown the effectiveness of these fibers for removal of some heavy metals, due to the lignin content in the natural fibers which plays an important role in the adsorption of metal cations (Lee et al., 2004; Troisi et al., 2008; C. Fallico, 2010). In the context of remediation techniques for unsaturated and/or saturated zone, an experimental approach for the hydraulic characterization of the "Furcraea andina" (i.e., Cabuya Blanca) fiber was carried out. This fiber is native to Andean regions and grows easily in wild or cultivated form in the valleys and hillsides of Colombia, Ecuador, and Peru. Fibers of "Furcraea andina" were characterized by experimental tests to determine their hydraulic conductivity or permeability and porosity in order to use this medium for bioremediation of contaminated aquifer exploiting the physical, chemical and microbial capacity of natural fiber in heavy metal adsorption. To evaluate empirically the hydraulic conductivity, laboratory tests were carried out at constant head specifically on the fibers manually extracted. For these tests we used a flow cell (used as permeameter), containing the "Furcraea andina" fibers to be characterized, suitably connected by a tygon pipe to a Marriott's bottle, which had a plastic tube that allow the adjustment of the hydraulic head for different tests to a constant value. By this experiment it was also possible to identify relationships that enable the estimation of permeability as a function of density, i.e. of the compaction degree of the fibers. Our study was carried out for three values of hydraulic head (H), namely 10, 18, and 25 cm and for each

  10. 液压钻机试验台的设计和应用%Hydraulic Drill Rig Test Rig Design and Application

    Institute of Scientific and Technical Information of China (English)

    张志萍

    2013-01-01

      介绍了加载方式对煤矿液压钻机利用磁粉进行加载、并由计算机自动采集数据的试验台,可检测液压钻机的转速、转矩、拉压力、流量等参数,确保液压钻机进出厂检验项目达标,保证了质量。%Introduce a method using magnetic powder loading method on coal mine hydraulic drill is loaded, and the computer automatic data collection experiment platform, can be detected in hydraulic drill speed, torque, pressure and flow, to ensure that the hydraulic drilling ma⁃chine import and factory inspection project standards, quality assurance.

  11. Magnetars and Gamma Ray Bursts

    CERN Document Server

    Bucciantini, N

    2012-01-01

    In the last few years, evidences for a long-lived and sustained engine in Gamma Ray Bursts (GRBs) have increased the attention to the so called millisecond-magnetar model, as a competitive alternative to the standard collapsar scenario. I will review here the key aspects of the {\\it millisecond magnetar} model for Long Duration Gamma Ray Bursts (LGRBs). I will briefly describe what constraints, present observations put on any engine model, both in term of energetic, outflow properties, and the relation with the associated Supernova (SN). For each of these I will show how the millisecond magnetar model satisfies the requirements, what are the limits of the model, how can it be further tested, and what observations might be used to discriminate against it. I will also discuss numerical results that show the importance of the confinement by the progenitor star in explaining the formation of a collimated outflow, how a detailed model for the evolution of the central engine can be built, and show that a wide varie...

  12. Coupled hydrogeophysical inversion using time-lapse magnetic resonance sounding and time-lapse gravity data for hydraulic aquifer testing: Will it work in practice?

    DEFF Research Database (Denmark)

    Herckenrath, Daan; Auken, Esben; Christiansen, Lars

    2012-01-01

    for the specific yield and hydraulic conductivity when considering a fully penetrating well and minimal data error. Using more conservative TL-RG and TL-MRS data error estimates according our own field experience strongly limited the informative value of the TL-RG data; TL-MRS data was less affected by this...... of representative measurement error correlation in the TL-RG data did not affect its informative value. A local sensitivity analysis showed that observations were most sensitive to the pumping rate and the thickness, specific yield, and hydraulic conductivity of the aquifer. The inclusion of TL-MRS data proved...

  13. OECD MCCI Small-Scale Water Ingression and Crust Strength Tests (SSWICS) SSWICS-3 test data report : thermal Hydraulic results, Rev. 0 February 19, 2003.

    Energy Technology Data Exchange (ETDEWEB)

    Lomperski, S.; Farmer, M. T.; Kilsdonk, D.; Aeschlimann, B. (Nuclear Engineering Division)

    2011-05-23

    The Melt Attack and Coolability Experiments (MACE) program at Argonne National Laboratory addressed the issue of the ability of water to cool and thermally stabilize a molten core/concrete interaction (MCCI) when the reactants are flooded from above. These tests provided data regarding the nature of corium interactions with concrete, the heat transfer rates from the melt to the overlying water pool, and the role of noncondensable gases in the mixing processes that contribute to melt quenching. However, due to the integral nature of these tests, several questions regarding the crust freezing behavior could not be adequately resolved. These questions include: (1) To what extent does water ingression into the crust increase the melt quench rate above the conduction-limited rate and how is this affected by melt composition and system pressure and (2) What is the fracture strength of the corium crust when subjected to a thermal-mechanical load and how does it depend upon the melt composition? A series of separate-effects experiments are being conducted to address these issues. The first employs an apparatus designed to measure the quench rate of a pool of corium ({approx}{phi}30 cm; up to 20 cm deep). The main parameter to be varied in these quench tests is the melt composition since it is thought to have a critical influence on the crust cracking behavior which, in turn, alters quench rate. The issue of crust strength will be addressed with a second apparatus designed to mechanically load the crust produced by the quench tests. This apparatus will measure the fracture strength of the crust while under a thermal load created by a heating element beneath the crust. The two apparatuses used to measure the melt quench rate and crust strength are jointly referred to as SSWICS (Small-Scale Water Ingression and Crust Strength). This report describes results of the third water ingression test, designated SSWICS-3. This test investigated the quenching behavior of a fully

  14. OECD MCCI project Small-Scale Water Ingression and Crust Strength Tests (SSWICS) SSWICS-1 test data report : thermal hydraulic results. Rev. 0 September 20, 2002.

    Energy Technology Data Exchange (ETDEWEB)

    Lomperski, S.; Farmer, M. T.; Kilsdonk, D. J.; Aeschlimann, R. W.; Basu, S. (Nuclear Engineering Division); (NRC)

    2011-05-23

    The Melt Attack and Coolability Experiments (MACE) program at Argonne National Laboratory addressed the issue of the ability of water to cool and thermally stabilize a molten core/concrete interaction (MCCI) when the reactants are flooded from above. These tests provided data regarding the nature of corium interactions with concrete, the heat transfer rates from the melt to the overlying water pool, and the role of noncondensable gases in the mixing processes that contribute to melt quenching. However, due to the integral nature of these tests, several questions regarding the crust freezing behavior could not be adequately resolved. These questions include: (1) To what extent does water ingression into the crust increase the melt quench rate above the conduction-limited rate and how is this affected by melt composition and system pressure and (2) What is the fracture strength of the corium crust when subjected to a thermal-mechanical load and how does it depend upon the melt composition? A series of separate-effects experiments are being conducted to address these issues. The first employs an apparatus designed to measure the quench rate of a pool of corium ({approx}{phi}30 cm; up to 20 cm deep). The main parameter to be varied in these quench tests is the melt composition since it is thought to have a critical influence on the crust cracking behavior which, in turn, alters quench rate. The issue of crust strength will be addressed with a second apparatus designed to mechanically load the crust produced by the quench tests. This apparatus will measure the fracture strength of the crust while under a thermal load created by a heating element beneath the crust. The two apparatuses used to measure the melt quench rate and crust strength are jointly referred to as SSWICS (Small-Scale Water Ingression and Crust Strength). This report describes results of the first water ingression test, designated SSWICS-1. The report includes a description of the test apparatus, the

  15. OECD MMCI Small-Scale Water Ingression and Crust Strength Tests (SSWICS) SSWICS-2 test data report : thermal hydraulic results, Rev. 0 September 20, 2002.

    Energy Technology Data Exchange (ETDEWEB)

    Lomperski, S.; Farmer, M. T.; Kilsdonk, D. J.; Aeschlimann, R. W.; Basu, S. (Nuclear Engineering Division); (NRC)

    2011-05-23

    The Melt Attack and Coolability Experiments (MACE) program at Argonne National Laboratory addressed the issue of the ability of water to cool and thermally stabilize a molten core/concrete interaction (MCCI) when the reactants are flooded from above. These tests provided data regarding the nature of corium interactions with concrete, the heat transfer rates from the melt to the overlying water pool, and the role of noncondensable gases in the mixing processes that contribute to melt quenching. However, due to the integral nature of these tests, several questions regarding the crust freezing behavior could not be adequately resolved. These questions include: (1) To what extent does water ingression into the crust increase the melt quench rate above the conduction-limited rate and how is this affected by melt composition and system pressure and (2) What is the fracture strength of the corium crust when subjected to a thermal-mechanical load and how does it depend upon the melt composition? A series of separate-effects experiments are being conducted to address these issues. The first employs an apparatus designed to measure the quench rate of a pool of corium ({approx}{phi}30 cm; up to 20 cm deep). The main parameter to be varied in these quench tests is the melt composition since it is thought to have a critical influence on the crust cracking behavior which, in turn, alters quench rate. The issue of crust strength will be addressed with a second apparatus designed to mechanically load the crust produced by the quench tests. This apparatus will measure the fracture strength of the crust while under a thermal load created by a heating element beneath the crust. The two apparatuses used to measure the melt quench rate and crust strength are jointly referred to as SSWICS (Small-Scale Water Ingression and Crust Strength). This report describes results of the second water ingression test, designated SSWICS-2. The report includes a description of the test apparatus, the

  16. Thermally Actuated Hydraulic Pumps

    Science.gov (United States)

    Jones, Jack; Ross, Ronald; Chao, Yi

    2008-01-01

    Thermally actuated hydraulic pumps have been proposed for diverse applications in which direct electrical or mechanical actuation is undesirable and the relative slowness of thermal actuation can be tolerated. The proposed pumps would not contain any sliding (wearing) parts in their compressors and, hence, could have long operational lifetimes. The basic principle of a pump according to the proposal is to utilize the thermal expansion and contraction of a wax or other phase-change material in contact with a hydraulic fluid in a rigid chamber. Heating the chamber and its contents from below to above the melting temperature of the phase-change material would cause the material to expand significantly, thus causing a substantial increase in hydraulic pressure and/or a substantial displacement of hydraulic fluid out of the chamber. Similarly, cooling the chamber and its contents from above to below the melting temperature of the phase-change material would cause the material to contract significantly, thus causing a substantial decrease in hydraulic pressure and/or a substantial displacement of hydraulic fluid into the chamber. The displacement of the hydraulic fluid could be used to drive a piston. The figure illustrates a simple example of a hydraulic jack driven by a thermally actuated hydraulic pump. The pump chamber would be a cylinder containing encapsulated wax pellets and containing radial fins to facilitate transfer of heat to and from the wax. The plastic encapsulation would serve as an oil/wax barrier and the remaining interior space could be filled with hydraulic oil. A filter would retain the encapsulated wax particles in the pump chamber while allowing the hydraulic oil to flow into and out of the chamber. In one important class of potential applications, thermally actuated hydraulic pumps, exploiting vertical ocean temperature gradients for heating and cooling as needed, would be used to vary hydraulic pressures to control buoyancy in undersea research

  17. CRITICAL HYDROLOGIC CONDITIONS FOR OVERFLOW BURST OF MORAINE LAKE

    Institute of Scientific and Technical Information of China (English)

    JIANG Zhong-xin; CUI Peng; JIANG Liang-wei

    2004-01-01

    Floodwater and debris flow caused by glacial lake burst is an important land process and a serious mountain disaster in glacial area of Xizang (Tibet) Autonomous Region, and the overflow burst is mainly caused by glacial landslide falling into moraine lake. On the premise that moraine lake is full, instantaneous burst in part of the lake bank happens, as flow velocity at burst mouth caused by overflow head is higher than threshold flow velocity of glacial till. Under some supposes, d90 and d10 of the glacial till in the bank were used as the threshold sizes of coarse and fine grains respectively. Thus, the formula of calculating threshold flow velocity of uniform sand was simplified,and threshold flow velocity of glacial till was calculated with the formula. Then, with synthesis formula calculating flow velocity of instantaneous part burst, flow velocity at overflow burst mouth was calculated, and calculation formula of critical height (H0) of overflow head was derived. Overflow head was caused by volume and surge of glacial landslide falling into moraine lake, calculation formulas of ascendant height (H1) of lake water surface and surge height (H2) on burst mouth caused by glacial landslide falling into moraine lake were derived. To sum up, critical hydrologic conditions of moraine lake burst with overflow form are: the burst is inevitable as H1 >H0; the burst is possible as H1 <H0 and (H1+H2) >H0; the burst is impossible as (H1+H2) <H0. In the factors influencing the burst critical conditions, it is advantageous for the burst that scale of the lake is 105n2 range; terminal glacial till is more fine and is even more uniform; the width of overflow mouth is even smaller than the length of the bank; the landslide haslarge scale and steep slip surface; and glacial end is close to the lake. With burst of Guangxiecuo Lake in Midui Valley of the Polongzanghu River in Xizang as an example, the burst critical conditions were tested.

  18. In-situ falling-head test for hydraulic conductivity: Evaluation in layered sediments of an analysis derived for homogenous sediments

    Science.gov (United States)

    Burnette, Matthew C.; Genereux, David P.; Birgand, François

    2016-08-01

    The hydraulic conductivity (K) of streambeds is a critical variable controlling interaction of groundwater and surface water. The Hvorslev analysis for estimating K from falling-head test data has been widely used since the 1950s, but its performance in layered sandy sediments common in streams and lakes has not previously been examined. Our numerical simulations and laboratory experiments show that the Hvorslev analysis yields accurate K values in both homogenous sediment (for which the analysis was originally derived) and layered deposits with low-K sand over high-K sand. K from the Hvorslev analysis deviated significantly from true K only when two conditions were present together: (1) high-K sand was present over low-K sand, and (2) the bottom of the permeameter in which K was measured was at or very near the interface between high-K and low-K. When this combination of conditions exists, simulation and laboratory sand tank results show that in-situ Hvorslev K underestimates the true K of the sediment within a permeameter, because the falling-head test is affected by low-K sediment outside of (below the bottom of) the permeameter. In simulation results, the maximum underestimation (occurring when the bottom of the permeameter was at the interface of high K over low K) was by a factor of 0.91, 0.59, and 0.12 when the high-K to low-K ratio was 2, 10, and 100, respectively. In laboratory sand tank experiments, the underestimation was by a factor of about 0.83 when the high-K to low-K ratio was 2.3. Also, this underestimation of K by the Hvorslev analysis was about the same whether the underlying low-K layer was 2 cm or 174 cm thick (1% or 87% of the domain thickness). Numerical model simulations were useful in the interpretation of in-situ field K profiles at streambed sites with layering; specifically, scaling the model results to the maximum measured K at the top of the field K profiles helped constrain the likely ratio of high K to low K at field locations with

  19. Testing of marrow coal bed systems by hydraulic driving device for thin films of coal; Ensayo de un Sistema de Arranque con Cepillo mediante Accionamiento Hidraulico para Capas Estrechas de CArbon

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    This researching project had the aim of: Testing a new mining system performance at narrow coal bed, which uses plough equipment with hydraulic driving devices. Minimising driving power group size to avoid problems regarding with the wall mining-heading transition, decreasing the needed room to house it and thus simplifying wall mining edge support The expected goals were: Take advantage of hydraulic driving devices to obtain a good efficiency with a variable and discontinuous load, bu t without loosing the electric driving devices advantages, consisting on increase driving torque, being the engine blocked Lengthen the mechanical equipment life (chains, driving sprockets, etc.) Reach and economic production rate Researching project was developed in El Bierzo basin (Leon, Spain), in Grupo Ampliacion, a mining group belonged to Viloria Hnos S. A.. (Author)

  20. Brake Performance Simulation and Test Analysis of Hydraulic Hybrid Bus%液压混合动力公交车制动性能仿真与试验分析

    Institute of Scientific and Technical Information of China (English)

    曲金玉; 李训明; 任传波; 韩尔樑; 刘林

    2014-01-01

    In consideration of city buses operating characteristics and poor fuel economy in urban driving cycles, we present a novel hydraulic hybrid system, and build three models, i.e. brake energy recovery dynamic model, energy regeneration dynamic model and diesel hydraulic start model, and then make brake performance simulation. Finally we test performance of the system by bench and road test. The results show that the hydraulic hybrid bus is capable of braking energy recovery, braking energy recovery rate in typical urban driving cycle is up to 69.7 % and energy regeneration rate is 32.8%, hydraulic engine start time is 1.7 second.%针对城市公交车运行特点和在城市运行工况下燃油经济性差的问题,提出一种新型液压混合动力系统,并建立制动回收过程动力学模型、能量再生过程动力学模型和柴油机液压起动模型等,对其制动性能进行仿真,最后进行了样机台架、实车道路试验。试验结果表明,该液压混合动力公交车可实现汽车制动能量回收等功能,在典型城市循环工况下制动能量回收率为69.7%,制动能量再生率为32.8%,液压起动发动机时间为1.7 s。

  1. Design&Manufacturing of Hydraulic Pump Test-bed with Power Recovery%功率回收型液压泵试验台的设计与制造

    Institute of Scientific and Technical Information of China (English)

    王文凯; 宫景瑞; 刘玉峰; 马忠

    2015-01-01

    一般来说,液压泵出厂试验、型式试验及寿命试验使用的试验设备,其驱动功率是由被试泵所能产生和达到的功率所决定的.在进行试验项目测试时,泵所产生的压力能不是来做功,而是要经过节流或溢流加载的方式转换成热能或其他形式来把它消耗掉.在液压试验台的设计和制造中,能否对这部分能量进行回收和利用,而不是任其被动消耗,这是该文要讨论和解决的问题.%As a rule, The test equipment which be used in hydraulic pump's factory test, type test and life test, It's driving power is deter-mined by the peak energy of tested Pump. In test run, the pump's pressure energy is not for working, but for transforming into heat energy or other forms by throttling or overflow loading. There is a problem in design and fabrication of hydraulic pump test-bedthat is whether this part of the energy can be reclaimed and reused rather than consumed passively. This paper will discuss and solve this problem.

  2. 超临界水实验回路热工水力分析%Thermal-hydraulic Analysis of SWAMUP Test Facility

    Institute of Scientific and Technical Information of China (English)

    汪子迪; 曹臻; 刘晓晶; 程旭

    2015-01-01

    system code ATHLET‐SC is capable of simulating thermal‐hydraulic behaviors during the trans‐critical transient .According to the results ,the wall tempera‐ture of heating rod during the transient is kept below the design limit .However ,the pressure difference between the heat exchanger inside and outside after depressurization could reach 6 M Pa ,w hich should be considered in the test .

  3. Vibration of hydraulic machinery

    CERN Document Server

    Wu, Yulin; Liu, Shuhong; Dou, Hua-Shu; Qian, Zhongdong

    2013-01-01

    Vibration of Hydraulic Machinery deals with the vibration problem which has significant influence on the safety and reliable operation of hydraulic machinery. It provides new achievements and the latest developments in these areas, even in the basic areas of this subject. The present book covers the fundamentals of mechanical vibration and rotordynamics as well as their main numerical models and analysis methods for the vibration prediction. The mechanical and hydraulic excitations to the vibration are analyzed, and the pressure fluctuations induced by the unsteady turbulent flow is predicted in order to obtain the unsteady loads. This book also discusses the loads, constraint conditions and the elastic and damping characters of the mechanical system, the structure dynamic analysis, the rotor dynamic analysis and the system instability of hydraulic machines, including the illustration of monitoring system for the instability and the vibration in hydraulic units. All the problems are necessary for vibration pr...

  4. Research and Design of Hydraulic CAT Comprehensive Test Platform Based on Modularization Idea%基于模块化的液压CAT综合试验平台的研究与设计

    Institute of Scientific and Technical Information of China (English)

    胡少刚; 印成

    2012-01-01

    Combining the present situation of hydraulic products on static and dynamic performance test platform, this paper studies CAT technology of hydraulic test platform and design program. It designs the overall structure of the test platform and CAT software system based on modular design, and the structure of the test bench innovatively. The joint control mode with regard to computer data processing is of powerful ability and PLC high reliability. Friendly interface and real -time display control software are developed, which greatly enhances the comprehensive function and technical integration of the test platform, offering innovate design and development ideas for enterprises and universities hydraulic CAT comprehensive test platform.%结合液压产品静、动态性能测试平台现状,研究了液压试验平台CAT技术和设计方案。基于模块化设计思想设计了试验平台总体结构和CAT软件系统。创新设计了试验台架结构,采用计算机和PLC联合控制模式,具有控制精度高、可靠性好的特点。开发了界面友好、实时显示的测控软件,大大提升了试验平台的综合功能和技术集成度,为企业和高校液压CAT综合试验平台的设计开发创新了思路。

  5. Solar Partial N-burst

    Institute of Scientific and Technical Information of China (English)

    Zong-Jun Ning; Yu-Ying Liu; Qi-Jun Fu; Fu-Ying Xu

    2003-01-01

    We present a new sub-class of type III solar radio burst at the highfrequencies around 6.0 GHz. In addition to a descending and an ascending branchon the dynamic spectrum, it has an inverted morphology different from the simpletype U-burst. We call it "partial N-burst" because it is interpreted as the knownN-burst minus its first branch. The partial N-burst presented here was detectedamong a reverse slope type III (RS-III) burst group prior to the type V solar radiocontinuum and was simultaneously recorded by two spectrometers at the NationalAstronomical Observatories, Chinese Academy of Sciences (NAOC, 5.20-7.60 GHz)and at Purple Mountain Observatory (PMO, 4.50-7.50 GHz) on 1999 August 25.After the N-burst and M-burst, the partial N-burst is a third piece of evidence for amagnetic mirror effect in solar radio observation, when the same electron is reflectedat a pinched foot of a flare loop.

  6. Gamma-ray burst spectra

    Science.gov (United States)

    Teegarden, B. J.

    1982-01-01

    A review of recent results in gamma-ray burst spectroscopy is given. Particular attention is paid to the recent discovery of emission and absorption features in the burst spectra. These lines represent the strongest evidence to date that gamma-ray bursts originate on or near neutron stars. Line parameters give information on the temperature, magnetic field and possibly the gravitational potential of the neutron star. The behavior of the continuum spectrum is also discussed. A remarkably good fit to nearly all bursts is obtained with a thermal-bremsstrahlung-like continuum. Significant evolution is observed of both the continuum and line features within most events.

  7. Construction and execution of experiments at the multi-purpose thermal hydraulic test facility TOPFLOW for generic investigations of two-phase flows and the development and validation of CFD codes - Final report

    OpenAIRE

    2010-01-01

    The works aimed at the further development and validation of models for CFD codes. For this reason, the new thermal-hydraulic test facility TOPFLOW was erected and equipped with wire-mesh sensors with high spatial and time resolution. Vertical test sections with nominal diameters of DN50 and DN200 operating with air-water as well as steam-water two-phase flows provided results on the evaluation of flow patterns, on the be¬haviour of the interfacial area as well as on interfacial momentum and ...

  8. Development of Multi-function Hydraulic Part Test Rig%某型飞机多功能液压部件特性测试装置的研制

    Institute of Scientific and Technical Information of China (English)

    李生杰; 田剑波; 曹丹青; 王鸿鑫; 俞兴民

    2013-01-01

    针对某型飞机液压系统的研制,构建了基于阻燃磷酸酯基液压油的多功能液压部件特性测试装置,包括泵源部分、测试台架、测试控制系统等,可对飞机发动机驱动泵、电动泵、能源转换装置、伺服阀、液压作动筒等多种部件进行测试,装置与阻燃磷酸酯基液压油相容,实现了机电系统集成及自动化测试.%In qrder to fulfill the development requirement of some type of aircraft, a multi-function hydraulic part test rig was built, including pump system, test bench, test control system, etc. it could test aircraft engine-driven pumps, electric pumps, power transfer units, servo valves, hydraulic actuators and so on. This test rig has good compatibility with fire resistant phosphate ester oil, and it has realized automated test and good integration between mechanical and electrical systems.

  9. M1078 Hybrid Hydraulic Vehicle Fuel Economy Evaluation

    Science.gov (United States)

    2012-09-01

    PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM-YYYY) 28-09-2012 2. REPORT TYPE Interim Report 3. DATES COVERED (From...system shakedown and developmental testing. During developmental testing, a hydraulic motor failure occurred. Although not catastrophic, the motor...main hydraulic hybrid system control module to request the TCM to shift the transmission. Clutch Operation with engine- off (hydraulic-only power) or

  10. Dark Gamma Ray Bursts

    CERN Document Server

    Brdar, Vedran; Liu, Jia

    2016-01-01

    Many theories of dark matter (DM) predict that DM particles can be captured by stars via scattering on ordinary matter. They subsequently condense into a DM core close to the center of the star and eventually annihilate. In this work, we trace DM capture and annihilation rates throughout the life of a massive star and show that this evolution culminates in an intense annihilation burst coincident with the death of the star in a core collapse supernova. The reason is that, along with the stellar interior, also its DM core heats up and contracts, so that the DM density increases rapidly during the final stages of stellar evolution. We argue that, counterintuitively, the annihilation burst is more intense if DM annihilation is a p-wave process than for s-wave annihilation because in the former case, more DM particles survive until the supernova. If among the DM annihilation products are particles like dark photons that can escape the exploding star and decay to Standard Model particles later, the annihilation bu...

  11. Ceruloplasmin decreases respiratory burst reaction during pregnancy.

    Science.gov (United States)

    Varfolomeeva, Elena Y; Semenova, Elena V; Sokolov, Alexey V; Aplin, Kirill D; Timofeeva, Kseniya E; Vasilyev, Vadim B; Filatov, Michael V

    2016-08-01

    Testing of pregnant women reveals weakening of neutrophil-mediated effector functions, such as reactive oxygen species generation. This study provides data confirming the phenomenon, gained through application of the flow cytometry technique. Key factors influencing neutrophil functional activity in blood plasma of pregnant women have not been detected so far. At the same time, concentration of ceruloplasmin - a copper-containing glycoprotein - is known to increase in blood significantly during pregnancy. We observed the negative correlation between ceruloplasmin concentration in blood plasma of pregnant women and the intensity of respiratory burst of neutrophils. Fractionation of plasma using gel-filtration revealed that ceruloplasmin-containing fraction demonstrated suppression of the respiratory burst reaction. Partial elimination of ceruloplasmin from the blood of pregnant women, performed with the help of specific antibodies and followed by immunoprecipitation, leads to an increased respiratory burst reaction. On the contrary, addition of ceruloplasmin to blood samples of healthy donors noticeably decreases the respiratory burst reaction. The results presented prove that change in ceruloplasmin level in plasma is necessary and sufficient for modulating the ability of neutrophils to produce reactive oxygen species during pregnancy.

  12. Assessing the likely value of gravity and drawdown measurements to constrain estimates of hydraulic conductivity and specific yield during unconfined aquifer testing

    Science.gov (United States)

    Blainey, J.B.; Ferre, T. P. A.; Cordova, J.T.

    2007-01-01

    Pumping of an unconfined aquifer can cause local desaturation detectable with high-resolution gravimetry. A previous study showed that signal-to-noise ratios could be predicted for gravity measurements based on a hydrologic model. We show that although changes should be detectable with gravimeters, estimations of hydraulic conductivity and specific yield based on gravity data alone are likely to be unacceptably inaccurate and imprecise. In contrast, a transect of low-quality drawdown data alone resulted in accurate estimates of hydraulic conductivity and inaccurate and imprecise estimates of specific yield. Combined use of drawdown and gravity data, or use of high-quality drawdown data alone, resulted in unbiased and precise estimates of both parameters. This study is an example of the value of a staged assessment regarding the likely significance of a new measurement method or monitoring scenario before collecting field data. Copyright 2007 by the American Geophysical Union.

  13. 10 MW高温气冷堆反应堆压力容器的出厂水压试验%Hydraulic Pressure Test of Pressure Vessel of 10 MW High Temperature Gas-cooled Reactor

    Institute of Scientific and Technical Information of China (English)

    刘俊杰; 张征明; 何树延; 王金海

    2001-01-01

    The hydraulic pressure test of 10MW Hight Temperature Gas-cooled Reactorc(HTR-10) pressure vessel was successfully performed according to the requirement of the section NB-6200, ASME Ⅲ code. The test requirement, the test results and the test evaluations are described in detail. The test tension was effectively and rationally done through an hydraulic tensionor, which was developed at institue of nuclear energy technology of Tsinghua University. The strain and deformation of the HTR-10 pressure vessel were also measured.%根据ASME规范第Ⅲ卷NB-6200节的规定,对10MW高温气冷堆压力容器的水压试验要求、试验过程,试验结果及评价进行了叙述。用清华大学核能技术设计研究院研制的液压张拉机对主螺栓实施了合理及有效的张拉,对压力容器进行了应变和变形测量,取得了反应堆压力容器水压试验的圆满成功。

  14. Design of a hydraulic bending machine

    Science.gov (United States)

    Steven G. Hankel; Marshall Begel

    2004-01-01

    To keep pace with customer demands while phasing out old and unserviceable test equipment, the staff of the Engineering Mechanics Laboratory (EML) at the USDA Forest Service, Forest Products Laboratory, designed and assembled a hydraulic bending test machine. The EML built this machine to test dimension lumber, nominal 2 in. thick and up to 12 in. deep, at spans up to...

  15. 水下采油树地面测试单元液压控制系统设计与仿真%Design and Simulation of the Ground Test Unit Hydraulic Control System for Subsea Tree

    Institute of Scientific and Technical Information of China (English)

    欧宇钧; 袁晓兵; 卢沛伟; 罗玉贵; 杨文; 苏瑞华; 张云卫; 张长齐; 蔡宝平

    2016-01-01

    The test of subsea tree can provide a reference for its maintenance. A ground test unit hydraulic control system for subsea trees was designed according to the principal parameters of subsea tree control system and subsea tree test procedures. It contained fluid reservoir, high pressure pump circuit, water pump circuit, accumulators, pressure regulating circuit, interface circuit and return cir⁃cuit. Then the main parameters of the hydraulic system key components were calculated, based on the principal parameters of subsea tree control system and subsea tree test requirements. AMESim was used for modeling and simulation of the ground test unit hydraulic control system. Through the analysis of simulation results, it is proved that the test unit can provide stable hydraulic fluid and it has a good con⁃trol effect.%对水下采油树进行测试验证可为水下采油树的维修保养提供参考。通过对水下采油树控制系统主参数以及水下采油树测试流程的研究,设计一套水下采油树地面测试单元液压控制系统,水下采油树地面测试单元液压控制系统包括油箱、高压泵回路、水泵回路、蓄能器组、调压回路、接口回路、回油回路等。根据系统主参数及测试要求,对液压控制系统主要元件进行主参数的计算。利用AMESim软件建立水下采油树地面测试单元液压控制系统模型,对模型进行仿真分析。结果表明,所设计的液压控制系统具有良好的控制性和稳定性。

  16. Short duration gamma ray bursts

    Indian Academy of Sciences (India)

    Patrick Das Gupta

    2004-10-01

    After a short review of gamma ray bursts (GRBs), we discuss the physical implications of strong statistical correlations seen among some of the parameters of short duration bursts (90 < 2 s). Finally, we conclude with a brief sketch of a new unified model for long and short GRBs.

  17. Bursts de raios gama

    Science.gov (United States)

    Braga, J.

    2003-02-01

    Nos últimos anos, graças principalmente aos dados obtidos pelo Compton Gamma-Ray Observatory e pelo satélite ítalo-holandês BeppoSAX, grandes avanços foram obtidos no nosso conhecimento sobre os fascinantes e enigmáticos fenômenos conhecidos por "bursts"de raios gama. Neste trabalho é feita uma revisão sobre a fenomenologia desses misteriosos objetos e são apresentados os desenvolvimentos recentes nessa área palpitante da astrofísica moderna, ressaltando tanto os resultados observacionais obtidos até o momento quanto os modelos teóricos propostos para explixá-los.

  18. Quantum Key Based Burst Confidentiality in Optical Burst Switched Networks

    Directory of Open Access Journals (Sweden)

    A. M. Balamurugan

    2014-01-01

    Full Text Available The optical burst switching (OBS is an emergent result to the technology concern that could achieve a feasible network in future. They are endowed with the ability to meet the bandwidth requirement of those applications that require intensive bandwidth. There are more domains opening up in the OBS that evidently shows their advantages and their capability to face the future network traffic. However, the concept of OBS is still far from perfection facing issues in case of security threat. The transfer of optical switching paradigm to optical burst switching faces serious downfall in the fields of burst aggregation, routing, authentication, dispute resolution, and quality of service (QoS. This paper deals with employing RC4 (stream cipher to encrypt and decrypt bursts thereby ensuring the confidentiality of the burst. Although the use of AES algorithm has already been proposed for the same issue, by contrasting the two algorithms under the parameters of burst encryption and decryption time, end-to-end delay, it was found that RC4 provided better results. This paper looks to provide a better solution for the confidentiality of the burst in OBS networks.

  19. Quantum key based burst confidentiality in optical burst switched networks.

    Science.gov (United States)

    Balamurugan, A M; Sivasubramanian, A

    2014-01-01

    The optical burst switching (OBS) is an emergent result to the technology concern that could achieve a feasible network in future. They are endowed with the ability to meet the bandwidth requirement of those applications that require intensive bandwidth. There are more domains opening up in the OBS that evidently shows their advantages and their capability to face the future network traffic. However, the concept of OBS is still far from perfection facing issues in case of security threat. The transfer of optical switching paradigm to optical burst switching faces serious downfall in the fields of burst aggregation, routing, authentication, dispute resolution, and quality of service (QoS). This paper deals with employing RC4 (stream cipher) to encrypt and decrypt bursts thereby ensuring the confidentiality of the burst. Although the use of AES algorithm has already been proposed for the same issue, by contrasting the two algorithms under the parameters of burst encryption and decryption time, end-to-end delay, it was found that RC4 provided better results. This paper looks to provide a better solution for the confidentiality of the burst in OBS networks.

  20. FEMA DFIRM Hydraulic Structures

    Data.gov (United States)

    Minnesota Department of Natural Resources — This layer and accompanying attribute table is required whenever hydraulic structures are shown in the flood profile. It is also required if levees are shown on the...

  1. Constant-Pressure Hydraulic Pump

    Science.gov (United States)

    Galloway, C. W.

    1982-01-01

    Constant output pressure in gas-driven hydraulic pump would be assured in new design for gas-to-hydraulic power converter. With a force-multiplying ring attached to gas piston, expanding gas would apply constant force on hydraulic piston even though gas pressure drops. As a result, pressure of hydraulic fluid remains steady, and power output of the pump does not vary.

  2. Tidal current turbine based on hydraulic transmission system

    Institute of Scientific and Technical Information of China (English)

    Hong-wei LIU; Wei LI; Yong-gang LIN; Shun MA

    2011-01-01

    Tidal current turbines (TCTs) are newly developed electricity generating devices.Aiming at the stabilization of the power output of TCTs,this paper introduces the hydraulic transmission technologies into TCTs.The hydrodynamics of the turbine was analyzed at first and its power output characteristics were predicted.A hydraulic power transmission system and a hydraulic pitch-controlled system were designed.Then related simulations were conducted.Finally,a TCT prototype was manufactured and tested in the workshop.The test results have confirmed the correctness of the current design and availability of installation of the hydraulic system in TCTs.

  3. Temporal Shaping of High Peak Power Pulse Trains from a Burst-Mode Laser System

    Directory of Open Access Journals (Sweden)

    Jörg Körner

    2015-12-01

    Full Text Available It has been shown in the past that pulsed laser systems operating in the so-called “burst mode” are a beneficial approach to generate high peak power laser pulses at high repetition rates suitable for various applications. So far, most high-energy burst-mode laser systems put great effort into generating a homogeneous energy distribution across the burst duration, e.g., by shaping the pump pulse. In this work, we present a new shaping technique, which is able to produce arbitrary energy distributions within the burst by pre-shaping the seed pulse burst with a Pockels cell. Furthermore, this technique allows for the precompensation of any static modulations across the burst, which may be introduced during the subsequent amplification process. Therefore, a pulse burst with a uniform energy distribution can also be generated. The method is tested with an ultra-short pulse burst mode laser amplifier system producing bursts of a 1 ms duration with a pulse repetition rate of 1 MHz and a maximum output power of 800 W during the burst. Furthermore, a method to predict the influence of the amplifier on a non-uniformly shaped burst is presented and successfully tested to produce a pre-defined pulse shape after amplification.

  4. The Synergy of Gamma-Ray Burst Detectors in the GLAST Era

    Science.gov (United States)

    Band, David

    2008-01-01

    Simultaneous observations by the large number of gamma-ray burst detectors that will operate in the GLAST era will provide the spectra, lightcurves and locations necessary for studying burst physics and testing the putative relations between intrinsic burst properties. I review the burst detection sensitivities, spectral bands, and localization capabilities of the GLAST (GBM and LAT), Swift (BAT), INTEGRAL (ISGRI), Suzaku (wAM), AGILE (Super-AGILE) and wind (Konus) detectors; the detectors' energy band and the accumulation timescale of their trigger system affect their sensitivity to hard vs. soft and long vs. short bursts. In addition, I estimate the rate of simultaneous burst observations. In particular, coordination of the Swift observing plan consistent with Swift's other science objectives could increase the rate of GLAST bursts with redshifts

  5. An Analysis of Burst Disc Pressure Instability

    Energy Technology Data Exchange (ETDEWEB)

    S. L. Robinson; B. C. Odegard, Jr.; N. r. Moody; S. H. Goods

    2000-06-01

    During the development stage of the 1X Acorn burst disc, burst pressure test results exhibited an unexpected increase of 8 to 14% over times of 90--100 days from initial fabrication. This increase is a concern where design constraints require stability. The disc material, 316L stainless steel sheet, is formed to a dome-like geometry and scored to produce a thin-walled, high-strength ligament. The fracture events controlling burst occur in that ligament. Thus it has been characterized both for tensile properties and microstructure through nanoindentation, magnetic measurements, optical and transmission electron microscopy. These results compare favorably with finite element simulation of the properties of the ligament. The ligament exhibits a highly heterogeneous microstructure; its small volume and microstructural heterogeneity make it difficult to identify which microstructural feature controls fracture and hence burst pressure. Bulk mechanical test specimens were fabricated to emulate mid-ligament properties, and aged at both room and elevated temperatures to characterize and accelerate the temporal behavior of the burst disc. Property changes included yield and ultimate tensile strength increases, and fracture strain decreases with aging. Specimens were subjected to a reversion anneal identical to that given the burst disc to eliminate the martensite phase formed during rolling. Reversion-annealed samples exhibited no change in properties in room temperature or accelerated aging, showing that the reversion-anneal eliminated the aging phenomenon. Aging was analyzed in terms of diffusion controlled precipitate growth kinetics, showing that carbon migration to dislocations is consistent with the strength increases. A vacancy-assisted diffusion mechanism for carbon transport is proposed, giving rise to rapid aging, which replaces interstitial carbon diffusion until excess vacancies from deformation are consumed. Mechanical activation parameters in stress relaxation

  6. Design and Test for Hydraulic System of Self-propelled Tea Plucker%自走式采茶机液压系统的设计和试验研究

    Institute of Scientific and Technical Information of China (English)

    韩余; 肖宏儒; 秦广明; 陈东胜; 宋志禹; 丁文芹; 梅松

    2014-01-01

    To design a simple, reasonable and robust hydraulic system for self-propelled tea plucker, this paper designed the hydraulic system firstly based on analyzing the actions and operating environment of self-propelled tea Plucker, and then conducted a functional-simulation to whole system with Sim Hydraulic, including traveling simulating and plucking simulating. And also the prototype test was carried out. The system consists mainly of three subsystems:two closed travel loops, whose system pressure is 17.6 MPa, encompass separately a variable pump and a constant-displacement motor with a volumetric speed-control scheme; an open loop, whose pressure is 10 MPa, comprises a constant-displacement pump and a constant-displacement motor used for plucking. The disparity between simulating results and the design values of the system pressure was 2.78% and 0.91% respectively, the difference between test values and design values was 4.82% and 14.3%. All in all, both the simulation and the test were basically in accorded with the design, which indicates the well function of the designed hydraulic system meets well the needs of self-propelled tea plucking machine.%为了设计简单、合理、可靠的自走式采茶机液压系统,首先进行了其液压系统原理与选型设计,并利用Sim Hydraulic对液压系统进行了功能数值仿真,最后进行样机试验。行驶液压子系统采用双泵双回路闭式容积调速方案,单个回路由双向变量泵与定量马达实现容积调速,系统设计压力为17.6 MPa。采摘子系统为一般开式回路,设计系统压力为10 MPa。系统压力的仿真结果与设计值分别相差2.78%和0.91%,试验结果与设计值分别相差为4.82%和14.3%,仿真、试验结果与设计目标基本相符,表明设计的液压系统能够很好地满足自走式采茶机的作业要求。

  7. The GLAST Burst Monitor (GBM)

    OpenAIRE

    Lichti, G. G.; Briggs, M.S.; Diehl, R.; Fishman, G.; Georgii, R.; Kippen, R. M.; Kouveliotou, C.; Meegan, C.; Paciesas, W.; Preece, R.; Schoenfelder, V.; von Kienlin, A.

    2001-01-01

    The selection of the GLAST burst monitor (GBM) by NASA will allow the investigation of the relation between the keV and the MeV-GeV emission from gamma-ray bursts. The GBM consists of 12 NaI and 2 BGO crystals allowing a continuous measurement of the energy spectra of gamma-ray bursts from ~5 keV to \\~30 MeV. One feature of the GBM is its high time resolution for time-resolved gamma-ray spectroscopy. Moreover the arrangement of the NaI crystals allows a rapid on-board location (

  8. Concept for LEU Burst Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Klein, Steven Karl [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Kimpland, Robert Herbert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-03-07

    Design and performance of a proposed LEU burst reactor are sketched. Salient conclusions reached are the following: size would be ~1,500 kg or greater, depending on the size of the central cavity; internal stresses during burst require split rings for relief; the reactor would likely require multiple control and safety rods for fine control; the energy spectrum would be comparable to that of HEU machines; and burst yields and steady-state power levels will be significantly greater in an LEU reactor.

  9. Prediction of failure strain and burst pressure in high yield-to-tensile strength ratio linepipe

    Energy Technology Data Exchange (ETDEWEB)

    Law, M. [Institute of Materials and Engineering Science, Australian Nuclear Science and Technology Organisation (ANSTO), Lucas Heights, NSW (Australia)]. E-mail: mlx@ansto.gov.au; Bowie, G. [BlueScope Steel Ltd., Level 11, 120 Collins St, Melbourne, Victoria 3000 (Australia)

    2007-08-15

    Failure pressures and strains were predicted for a number of burst tests as part of a project to explore failure strain in high yield-to-tensile strength ratio linepipe. Twenty-three methods for predicting the burst pressure and six methods of predicting the failure strain are compared with test results. Several methods were identified which gave accurate and reliable estimates of burst pressure. No method of accurately predicting the failure strain was found, though the best was noted.

  10. Thermal-Hydraulic System Study of the Helium Cooled Pebble Bed (HCPB) Test Blanket Module (TBM) for ITER Using System Code RELAP5

    Science.gov (United States)

    Jin, Xuezhou; R, Meyder

    2005-04-01

    The HCPB concept has been a European DEMO reference concept for nearly one decade. Detailed thermal-hydraulic study on the control behavior of the whole system is one of the important parts of this development. The thermal-hydraulic effect of the TBM-combined cooling circuit during a cyclic operation in ITER has been studied using the system code RELAP5. The RELAP5 is based on an one-dimensional, transient two-fluid model for the flow of a two-phase steam-water mixture that can contain noncondensable components like Helium. The RELAP5-models are modified to take the cyclic operation of the circulator, heat exchanger, bypass, valves etc in to account. A sequence of operational phases is investigated, starting from the cold state through the heating phase that brings the system to a stand-by condition, followed by typical power cycles applied in ITER. The results show that the implemented control mechanisms keep the inlet temperature to the TBM and the total mass flow rate at the required values through all phases.

  11. Thermal-Hydraulic System Study of the Helium Cooled Pebble Bed (HCPB) Test Blanket Module (TBM) for ITER Using System Code RELAP5

    Institute of Scientific and Technical Information of China (English)

    Jin Xuezhou; R. Meyder

    2005-01-01

    The HCPB concept has been a European DEMO reference concept for nearly one decade. Detailed thermal-hydraulic study on the control behavior of the whole system is one of the important parts of this development. The thermal-hydraulic effect of the TBM-combined cooling circuit during a cyclic operation in ITER has been studied using the system code RELAP5. The RELAP5 is based on an one-dimensional, transient two-fluid model for the flow of a two-phase steam-water mixture that can contain noncondensable components like Helium. The RELAP5-models are modified to take the cyclic operation of the circulator, heat exchanger, bypass, valves etc in to account. A sequence of operational phases is investigated, starting from the cold state through the heating phase that brings the system to a stand-by condition, followed by typical power cycles applied in ITER. The results show that the implemented control mechanisms keep the inlet temperature to the TBM and the total mass flow rate at the required values through all phases.

  12. 基于极端脉冲群骚扰的电能表研究与应用%Research and application of energy meter based on electrical fast transient/burst tests

    Institute of Scientific and Technical Information of China (English)

    吴思聪; 彭可; 罗湘运

    2011-01-01

    为排除电快速瞬变脉冲群抗扰试验中的主要故障,如表计复位、计量精度起伏大、个别元件受损等,在样机的改版改进工作中,分别在电压信号回路、电源供电回路、电流信号回路中针对脉冲的干扰方式和路径,增加了一些必要的抗扰措施,修改了一些关键的电路参数,同时也在表计软件设计方面进行了相应改进,实验结果表明,这些改进措施可有效抑制脉冲群对电能表的影响.%In order to exclude main fault of electrical fast transient/burst(EFT/B) tests, including the meter resetting, drastic measuring accuracy, individual components damaged and so on, based on several prototypes experiment in the meter research and development. Aiming at the disturbed mode and path of the pulse in voltage loop, power loop, current loop, the necessary immunity measure was increased, the key circuit parameters was modified, and software design were improved respectively. The test results show that these measures can inhibit the effect of EFT/B on meter effectively.

  13. Post-test calculation of the QUENCH-17 bundle experiment with debris formation and bottom water reflood using thermal hydraulic and severe fuel damage code SOCRAT/V3

    Energy Technology Data Exchange (ETDEWEB)

    Vasiliev, A., E-mail: vasil@ibrae.ac.ru [Nuclear Safety Institute (IBRAE), B. Tulskaya 52, 115191 Moscow (Russian Federation); Stuckert, J., E-mail: juri.stuckert@kit.edu [Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany)

    2015-03-15

    Highlights: • Modeling of processes in porous debris regions. • Analysis of coolability of massive debris bed. • Complexity of simulation of flow regime near boiling curve. - Abstract: The thermal hydraulic and SFD (Severe Fuel Damage) best estimate computer modeling code SOCRAT/V3 was used for the post-test analysis of the QUENCH-17 experiment performed at KIT on January 2013. The objective of this test was to examine the formation of a debris bed inside the completely oxidized region of the bundle without melt formation and to investigate the coolability behavior during the reflood. The test bundle for QUENCH-17 test was intentionally changed in comparison to basic QUENCH bundles (usually 21 heated rod simulators) with the emphasis to investigate debris behavior phenomena. Only 12 periphery fuel rod simulators were heated by centerline tungsten heaters. 9 unheated fuel rod simulators were located in the inner part of the test bundle. This is why the massive porous debris formation in the inner part of the bundle was not influenced by the presence of tungsten heaters. The QUENCH-17 test conditions simulated a hypothetical scenario of nuclear power plant severe accident sequence with debris bed formation in which the overheated up to 1800 K core would be flooded from the bottom by ECCS (Emergency Core Cooling System). The QUENCH-17 test included the following phases: (1) heat-up phase (heat-up rate up to 0.25 K/s); (2) oxidation phase (the cladding temperature about 1800 K in hottest region, steam mass flow rate 2 g/s); (3) bottom flood phase (characteristic cooling time about 600 s, water mass flow rate 10 g/s). SOCRAT/V3 computer modeling code was used for calculation of basic thermal hydraulic, oxidation and thermal mechanical behavior during all phases of the experiment. The calculated results are in a good agreement with experimental data which justifies the adequacy of modeling capabilities of SOCRAT code system.

  14. Burst Detector X-Ray IIR

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-02-01

    The Burst Detector X-Ray (BDX) instrument for the Block IIR series of Global Positioning System satellites is described. The BDX instrument can locate and characterize exoatmospheric nuclear detonations by using four sensors consisting of sets of filters over silicon diodes to detect x rays of various energies from the burst. On the BDX-IIR, a fifth sensor with a response spanning those of the other sensors confirms coincidences among the four main channels. The mechanical and electronic features of the BDX-IIR and its sensors are described. The calibrations and the system tests used in flight are presented. The commands for the BDX-IIR are given. The messages sent from the BDX-IIR are described in detail.

  15. Composite-flywheel burst-containment study

    Energy Technology Data Exchange (ETDEWEB)

    Sapowith, A D; Handy, W E

    1982-04-08

    A key component impacting total flywheel energy storage system weight is the containment structure. This report addresses the factors that shape this structure and define its design criteria. In addition, containment weight estimates are made for the several composite flywheel designs of interest so that judgements can be made as to the relative weights of their containment structure. The requirements set down for this program were that all containment weight estimates be based on a 1 kWh burst. It should be noted that typical flywheel requirements for regenerative braking of small automobiles call for deliverable energies of 0.25 kWh. This leads to expected maximum burst energies of 0.5 kWh. The flywheels studied are those considered most likely to be carried further for operational design. These area: The pseudo isotropic disk flywheel, sometimes called the alpha ply; the SMC molded disk; either disk with a carbon ring; the subcircular rim with cruciform hub; and Avco's bi-directional circular weave disk. The flywheel materials for the disk are S-glass; the subcircular rim is Kevlar over S-glass. Test data on flywheel bursts and containment failures were analyzed. Recommendations are made for further testing.

  16. Trend of hydraulic units

    Energy Technology Data Exchange (ETDEWEB)

    Deshimaru, Jun' ichi

    1988-11-01

    The gear, vane and piston pumps occupy a more then 90% share in the hydraulic pumps. Comparatively large pumps are mainly variable delivery piston pumps. The piston pumps are comparatively high in output density (output per unit weight), indicating the hydraulic pump in performance, and tend to become higher and higher in it. Though they are mainly 210 to 350kgf/cm/sup 2/ in rated pressure, some of them come to surpass 400kgf/cm/sup 3/ in it. While the progress in computation also requires the high speed operation, high accuracy and other severe conditions for the hydraulic units, which accordingly and increasingly intensify the requirement for hydraulic oil in abrasion resistibility, oxidation stability and response characteristics. While cavitation comes to easily occur, which considerably and disadvantageously influences hydraulic oil in life through degradation, noise level and respondingness. From now on, the development of high performance oil and study of mechanical structure are important. 19 references, 9 figures, 2 tables.

  17. 旋转导向液压系统关键部件测试平台研制%The Development of Platform for Testing Key Parts of Hydraulic System in Rotary Steerable Tool

    Institute of Scientific and Technical Information of China (English)

    贾建波; 孙师贤; 蒋荻南; 尚捷

    2014-01-01

    针对旋转导向液压系统工作可靠性验证,研发了一种可以测试旋转导向仪器液压系统关键部件性能的平台。实际应用表明,该测试平台可以完成微型柱塞泵工作性能参数的数字化测试,功能检验和效率评估功能,满足科研与工程使用的测试要求。%In order to verify the reliability of hydraulic system in rotary steerable tool , a platform is developed for testing the performance characteristics of key parts of hydraulic system in rotary steerable tool . The application of platform shows that it can complete digitization of performance characteristics , function test and efficiency evaluation with miniature piston pump , which meet the requirements of scientific research and engineering application .

  18. 30 CFR 57.3461 - Rock bursts.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Rock bursts. 57.3461 Section 57.3461 Mineral...-Underground Only § 57.3461 Rock bursts. (a) Operators of mines which have experienced a rock burst shall— (1) Within twenty four hours report to the nearest MSHA office each rock burst which: (i) Causes persons...

  19. Hydraulic conductivity tests on damaged geosynthetic clay liners%带缺陷膨润土防水毯的渗透试验

    Institute of Scientific and Technical Information of China (English)

    何俊; 肖衡林; 孔祥怡

    2011-01-01

    分别以自来水和0.05 mol/L的CaCl2溶液作为渗滤溶液研究带缺陷膨润土防水毯(GCL)的渗透性能.试验结果表明:自来水渗滤时,GCL的渗透系数随着缺陷直径的增大而增大,缺陷直径达11mm时缺陷不能完全愈合,致使渗透系数超过1×10-9m/s.CaCl2溶液渗滤时,随着离子交换作用的进行,渗透系数随孔隙体积流量的增大有增大的趋势;缺陷直径小于5mm时GCL具有一定的自愈能力,但增至7mm时缺陷不能愈合,溶液和缺陷的共同作用使得GCL的防渗性能很差.%The permeability of damaged geosynthetic clay liner (GCL) was studied fay using the tap water and the 0.05mol/L CaCl2 solution as the percolating liquid, respectively. The results show that for the taper water, the hydraulic conductivity of the damaged GCL increases with the increase of hole diameter. The damaged GCL can not self-heal when the hole diameter reaches 11mm, and the hydraulic conductivity will be larger than 1 × 10-9 m/s. For the 0.05mol/L CaCl2 solution, the hydraulic conductivity of the damaged GCL increases with the increase of pore volume flows due to ion exchange. The damaged GCL have certain self-healing capacity when the hole diameter is less than 5 mm and can not self-heal when the hole diameter reaches 7 mm. The combined action of the solution and the defect results in poor permeability performance of the damaged GCL.

  20. Disinhibition Bursting of Dopaminergic Neurons

    Directory of Open Access Journals (Sweden)

    Collin J Lobb

    2011-05-01

    Full Text Available Substantia nigra pars compacta (SNpc dopaminergic neurons receive strong tonic inputs from GABAergic neurons in the substantia nigra pars reticulata (SNpr and globus pallidus (GP, and glutamatergic neurons in the subthalamic nucleus. The presence of these tonic inputs raises the possibility that phasic disinhibition may trigger phasic bursts in dopaminergic neurons. We first applied constant NMDA and GABAA conductances onto a two-compartment single cell model of the dopaminergic neuron (Kuznetsov et al., 2006. The model exhibited disinhibition bursting upon stepwise removal of inhibition. A further bifurcation analysis suggests that disinhibition may be more robust than excitation alone in that for most levels of NMDA conductance, the cell remains capable of bursting even after a complete removal of inhibition, whereas too much excitatory input will drive the cell into depolarization block. To investigate the network dynamics of disinhibition, we used a modified version of an integrate-and-fire based model of the basal ganglia (Humphries et al., 2006. Synaptic activity generated in the network was delivered to the two-compartment single cell dopaminergic neuron. Phasic activation of the D1-expressing medium spiny neurons in the striatum (D1STR produced disinhibition bursts in dopaminergic neurons through the direct pathway (D1STR to SNpr to SNpc. Anatomical studies have shown that D1STR neurons have collaterals that terminate in GP. Adding these collaterals to the model, we found that striatal activation increased the intra-burst firing frequency of the disinhibition burst as the weight of this connection was increased. Our studies suggest that striatal activation is a robust means by which disinhibition bursts can be generated by SNpc dopaminergic neurons, and that recruitment of the indirect pathway via collaterals may enhance disinhibition bursting.

  1. Derivation of site-specific relationships between hydraulic parameters and p-wave velocities based on hydraulic and seismic tomography

    Energy Technology Data Exchange (ETDEWEB)

    Brauchler, R.; Doetsch, J.; Dietrich, P.; Sauter, M.

    2012-01-10

    In this study, hydraulic and seismic tomographic measurements were used to derive a site-specific relationship between the geophysical parameter p-wave velocity and the hydraulic parameters, diffusivity and specific storage. Our field study includes diffusivity tomograms derived from hydraulic travel time tomography, specific storage tomograms, derived from hydraulic attenuation tomography, and p-wave velocity tomograms, derived from seismic tomography. The tomographic inversion was performed in all three cases with the SIRT (Simultaneous Iterative Reconstruction Technique) algorithm, using a ray tracing technique with curved trajectories. The experimental set-up was designed such that the p-wave velocity tomogram overlaps the hydraulic tomograms by half. The experiments were performed at a wellcharacterized sand and gravel aquifer, located in the Leine River valley near Göttingen, Germany. Access to the shallow subsurface was provided by direct-push technology. The high spatial resolution of hydraulic and seismic tomography was exploited to derive representative site-specific relationships between the hydraulic and geophysical parameters, based on the area where geophysical and hydraulic tests were performed. The transformation of the p-wave velocities into hydraulic properties was undertaken using a k-means cluster analysis. Results demonstrate that the combination of hydraulic and geophysical tomographic data is a promising approach to improve hydrogeophysical site characterization.

  2. Soil hydraulic properties near saturation, an improved conductivity model

    DEFF Research Database (Denmark)

    Børgesen, Christen Duus; Jacobsen, Ole Hørbye; Hansen, Søren;

    2006-01-01

    The hydraulic properties near saturation can change dramatically due to the presence of macropores that are usually difficult to handle in traditional pore size models. The purpose of this study is to establish a data set on hydraulic conductivity near saturation, test the predictive capability...... of commonly used hydraulic conductivity models and give suggestions for improved models. Water retention and near saturated and saturated hydraulic conductivity were measured for a variety of 81 top and subsoils. The hydraulic conductivity models by van Genuchten [van Genuchten, 1980. A closed-form equation...... for predicting the hydraulic conductivity of unsaturated soils. Soil Sci. Soc. Am. J. 44, 892–898.] (vGM) and Brooks and Corey, modified by Jarvis [Jarvis, 1991. MACRO—A Model of Water Movement and Solute Transport in Macroporous Soils. Swedish University of Agricultural Sciences. Department of Soil Sciences...

  3. Burst Suppression: A Review and New Insights

    Directory of Open Access Journals (Sweden)

    Jonathan Dillon Kenny

    2014-12-01

    Full Text Available Burst suppression is a pattern of brain electrical activity characterized by alternating periods of high-amplitude bursts and electrical silence. Burst suppression can arise from several different pathological conditions, as well as from general anesthesia. Here we review current algorithms that are used to quantify burst suppression, its various etiologies, and possible underlying mechanisms. We then review clinical applications of anesthetic-induced burst suppression. Finally, we report the results of our new study showing clear electrophysiological differences in burst suppression patterns induced by two common general anesthetics, sevoflurane and propofol. Our data suggest that the circuit mechanisms that generate burst suppression activity may differ between different general anesthetics.

  4. VIRTUAL DESIGN OF A NEW TYPE OF HYDRAULIC SUPPORT

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Using virtual reality to design a new type of hydraulic support is discussed. That is how to make use of the virtual design to develop coal mining machine in practice. The advantages of virtual design are studied and the simple virtual reality system is built. The 3D parts and elements of hydraulic support are modeled with parametric design in CAD software, then exported to VR environment, in which the virtual hydraulic support is assembled, operated and tested. With the method, the errors and faults of design can be fined easily, many improvements are made and the new hydraulic support is developed successfully.

  5. Gamma-ray burst models.

    Science.gov (United States)

    King, Andrew

    2007-05-15

    I consider various possibilities for making gamma-ray bursts, particularly from close binaries. In addition to the much-studied neutron star+neutron star and black hole+neutron star cases usually considered good candidates for short-duration bursts, there are also other possibilities. In particular, neutron star+massive white dwarf has several desirable features. These systems are likely to produce long-duration gamma-ray bursts (GRBs), in some cases definitely without an accompanying supernova, as observed recently. This class of burst would have a strong correlation with star formation and occur close to the host galaxy. However, rare members of the class need not be near star-forming regions and could have any type of host galaxy. Thus, a long-duration burst far from any star-forming region would also be a signature of this class. Estimates based on the existence of a known progenitor suggest that this type of GRB may be quite common, in agreement with the fact that the absence of a supernova can only be established in nearby bursts.

  6. Estimation of ground water hydraulic parameters

    Energy Technology Data Exchange (ETDEWEB)

    Hvilshoej, Soeren

    1998-11-01

    The main objective was to assess field methods to determine ground water hydraulic parameters and to develop and apply new analysis methods to selected field techniques. A field site in Vejen, Denmark, which previously has been intensively investigated on the basis of a large amount of mini slug tests and tracer tests, was chosen for experimental application and evaluation. Particular interest was in analysing partially penetrating pumping tests and a recently proposed single-well dipole test. Three wells were constructed in which partially penetrating pumping tests and multi-level single-well dipole tests were performed. In addition, multi-level slug tests, flow meter tests, gamma-logs, and geologic characterisation of soil samples were carried out. In addition to the three Vejen analyses, data from previously published partially penetrating pumping tests were analysed assuming homogeneous anisotropic aquifer conditions. In the present study methods were developed to analyse partially penetrating pumping tests and multi-level single-well dipole tests based on an inverse numerical model. The obtained horizontal hydraulic conductivities from the partially penetrating pumping tests were in accordance with measurements obtained from multi-level slug tests and mini slug tests. Accordance was also achieved between the anisotropy ratios determined from partially penetrating pumping tests and multi-level single-well dipole tests. It was demonstrated that the partially penetrating pumping test analysed by and inverse numerical model is a very valuable technique that may provide hydraulic information on the storage terms and the vertical distribution of the horizontal and vertical hydraulic conductivity under both confined and unconfined aquifer conditions. (EG) 138 refs.

  7. Cavitation in Hydraulic Machinery

    Energy Technology Data Exchange (ETDEWEB)

    Kjeldsen, M.

    1996-11-01

    The main purpose of this doctoral thesis on cavitation in hydraulic machinery is to change focus towards the coupling of non-stationary flow phenomena and cavitation. It is argued that, in addition to turbulence, superimposed sound pressure fluctuations can have a major impact on cavitation and lead to particularly severe erosion. For the design of hydraulic devices this finding may indicate how to further limit the cavitation problems. Chapter 1 reviews cavitation in general in the context of hydraulic machinery, emphasizing the initial cavitation event and the role of the water quality. Chapter 2 discusses the existence of pressure fluctuations for situations common in such machinery. Chapter 3 on cavitation dynamics presents an algorithm for calculating the nucleation of a cavity cluster. Chapter 4 describes the equipment used in this work. 53 refs., 55 figs.,10 tabs.

  8. Evaluation of TASS/SMR with steady state analysis of high temperature/high pressure thermal-hydraulic test facility (VISTA)

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Dong Ju; Choi, Yong Won; Park, Chang Hwan; Lee, Un Chul [Seoul National University, Seoul (Korea, Republic of); Hwang, Young Dong; Lee, Kyu Hyung; Kim, Hee Chul [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    2005-07-01

    The TASS/SMR code is the revised version of the TASS code, which is the result of code development effort of KAERI since 1997, for safety analysis of NPP coolant system. Lately, it is scheduled to evaluate thermal-hydraulic phenomena during several transient periods of SMART-P with TASS/SMR. To establish the pertinence of the calculative results of TASS/SMR, there should be a process of validation and verification of TASS/SMR. The objective of this study is validating the numerical capability and reliability of TASS/SMR with steady state analysis of VISTA (Experimental Verification by Integral Simulation of Transient and Accidents) that was designed to simulate SMART-P.

  9. Computer code analysis of steam generator in thermal-hydraulic test facility simulating nuclear power plant; Ydinvoimalaitosta kuvaavan koelaitteiston hoeyrystimien analysointi tietokoneohjelmilla

    Energy Technology Data Exchange (ETDEWEB)

    Virtanen, E.

    1995-12-31

    In the study three loss-of-feedwater type experiments which were preformed with the PACTEL facility has been calculated with two computer codes. The purpose of the experiments was to gain information about the behaviour of horizontal steam generator in a situation where the water level on the secondary side of the steam generator is decreasing. At the same time data that can be used in the assessment of thermal-hydraulic computer codes was assembled. The purpose of the work was to study the capabilities of two computer codes, APROS version 2.11 and RELAP5/MOD3.1, to calculate the phenomena in horizontal steam generator. In order to make the comparison of the calculation results easier the same kind of model of the steam generator was made for both codes. Only the steam generator was modelled, the rest of the facility was given for the codes as a boundary condition. (23 refs.).

  10. 旋转阀式液压振动沉拔桩机实验系统特性分析%Dynamic characteristics of a test system for a hydraulic vibratory piling machine with a rotary valve

    Institute of Scientific and Technical Information of China (English)

    李小彭; 赵光辉; 梁亚敏; 闻邦椿

    2014-01-01

    为了实现连续沉桩,以周期振动激励规律为基础,设计了桩机用五口旋转阀模型,并以此模型为基础,设计了液压振动沉拔桩机实验系统。分别改变旋转阀孔径和频率对实验系统进行仿真,分析旋转阀各参数对系统动态性能和沉桩的影响,得到了旋转阀最佳参数:当旋转阀孔径为10 mm,旋转频率为20 Hz 时,系统工作特性最好,沉桩效率最高。最后通过实验,利用 B&K 数据采集分析系统获得了液压杆加速度曲线,实验结果与理论分析相符,验证了旋转阀理论分析的正确性和旋转阀式液压振动沉拔桩机实验系统的可行性。研究可为实际建筑工程施工中合理选择参数,提高工作效率提供依据。%In order to realize continuously sinking piles,the model of a five-way rotary valve was designed based on the periodic vibration excitation law,and then a test system of a hydraulic vibratory piling machine was designed.The hole diameter and rotating frequency of the rotary valve were changed to analyze their influence on the test system dynamic characteristics and get the best parameters of the valve with simulations.Simulation results showed that the test system working characteristics is the best and the sinking efficiency is the highest when the hole diameter of the valve is 10 mm and its rotating frequency is 20 Hz.Finally,tests were conducted and the acceleration curves of the hydraulic piston-rod were gained with B&K data acquisition and analysis system.The results demonstrated that the theoretical analysis of the five-way rotary valve is correct and the test system of the hydraulic vibratory piling machine is feasible.The research provided a basis for selecting reasonable parameters and improving work efficiency in practical construction system.

  11. Do Gamma-Ray Burst Sources Repeat?

    OpenAIRE

    Meegan, Charles A.; Hartmann, Dieter H.; Brainerd, J. J.; Briggs, Michael S.; Paciesas, William S.; Pendleton, Geoffrey; Kouveliotou, Chryssa; Fishman, Gerald; Blumenthal, George; Brock, Martin

    1995-01-01

    The demonstration of repeated gamma-ray bursts from an individual source would severely constrain burst source models. Recent reports (Quashnock and Lamb 1993; Wang and Lingenfelter 1993) of evidence for repetition in the first BATSE burst catalog have generated renewed interest in this issue. Here, we analyze the angular distribution of 585 bursts of the second BATSE catalog (Meegan et al. 1994). We search for evidence of burst recurrence using the nearest and farthest neighbor statistic and...

  12. Hydraulics and pneumatics

    CERN Document Server

    Parr, Andrew

    2006-01-01

    Nearly all industrial processes require objects to be moved, manipulated or subjected to some sort of force. This is frequently accomplished by means of electrical equipment (such as motors or solenoids), or via devices driven by air (pneumatics) or liquids (hydraulics).This book has been written by a process control engineer as a guide to the operation of hydraulic and pneumatic systems for all engineers and technicians who wish to have an insight into the components and operation of such a system.This second edition has been fully updated to include all recent developments su

  13. Popeye Project: Hydraulic umbilical

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, K.G.; Williams, V.T.

    1996-12-31

    For the Popeye Project, the longest super-duplex hydraulic umbilical in the world was installed in the Gulf of Mexico. This paper reports on its selection and project implementation. Material selection addresses corrosion in seawater, water-based hydraulic fluid, and methanol. Five alternatives were considered: (1) carbon-steel with traditional coating and anodes, (2) carbon-steel coated with thermally sprayed aluminum, (3) carbon-steel sheathed in aluminum, (4) super-duplex, and (5) titanium. The merits and risks associated with each alternative are discussed. The manufacture and installation of the selected umbilical are also reported.

  14. Hydraulic Arm Modeling via Matlab SimHydraulics

    OpenAIRE

    Věchet, Stanislav; Krejsa, Jiří

    2009-01-01

    System modeling is a vital tool for cost reduction and design process speed up in most engineering fields. The paper is focused on modeling of hydraulic arm as a part of intelligent prosthesis project, in the form of 2DOF open kinematic chain. The arm model combines mechanical, hydraulic and electric subsystems and uses Matlab as modeling tool. SimMechanics Matlab extension is used for mechanical part modeling, SimHydraulics toolbox is used for modeling of hydraulic circuit used for actuating...

  15. Maintaining Optimum Pump Performance with Specially- Formulated Hydraulic Fluids

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    This paper describes a battery of tests, and related results, that were performed under normal and severe conditions designed to demonstrate that hydraulic fluids formulated with Lubrizol' s high quality anti - wear hydraulic fluid technology can stand up to today's increasing demands for longer life and provide excellent performance under higher operating temperatures and pressures.

  16. THE THEORETICAL MODEL FOR PREDICTING CIRCULATION VELOCITY OF HYDRAULIC BRAKE

    Institute of Scientific and Technical Information of China (English)

    刘英林; 侯春生

    1997-01-01

    By rational hypothesis of fluid flow pattern, applied the law of conservation of energy and integrated the laboratory test results, finished the prediction by the theoretical model of circulation velocity of hydraulic brake which is important parameter. Thus provide the theoritical basis for hydraulic brake of belt conveyor whose research has just been started.

  17. Design of Transputer Controllers for Hydraulic Actuator Systems

    DEFF Research Database (Denmark)

    Conrad, Finn

    1996-01-01

    The paper deals with how transputers can be applied for fast controllers for hydraulic actuator systems. A general transputer-based control systems including a data acquisition transputer subsystem is presented. An application case: development of a mechatronic test facility with a fast hydraulic...

  18. FEASIBILITY OF HYDRAULIC FRACTURING OF SOILS TO IMPROVE REMEDIAL ACTIONS

    Science.gov (United States)

    Hydraulic fracturing, a technique commonly used to increase the yields of oil wells, could improve the effectiveness of several methods of in situ remediation. This project consisted of laboratory and field tests in which hydraulic fractures were created in soil. Laboratory te...

  19. 14 CFR 35.43 - Propeller hydraulic components.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Propeller hydraulic components. 35.43 Section 35.43 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: PROPELLERS Tests and Inspections § 35.43 Propeller hydraulic components....

  20. Comparison study between hydraulic simulation results and the standard test results of 87 type rainwater hopper%87型雨水斗标准测试与水力模拟计算的对比研究

    Institute of Scientific and Technical Information of China (English)

    李丽萍

    2016-01-01

    Although the 87 type rainwater hopper rainwater drainage system is based on the gravity water flow,there is still half-pressured water flow in the rainwater drainage system with 87 type rainwater hopper.Based on this fact and the hydraulic test results from producer,the numeri-cal simulation was used to analyze the drainage performance of the 87 type rainwater hopper under various rainwater intensities.In addition,a comparison study was carried out to study its hydraulic working condition including water depth before rainwater hopper,gas-water two-phase flow and discharge capacity.This paper might be reference for engineering application.%针对87型屋面雨水排水系统基于重力流设计但实际运行中可能存在半有压流态的特点,结合相关厂家的水力实测试验成果,引入数值模拟技术,分析各种降雨强度下87型雨水系统的排水性能,对比研究其水力工况(斗前水深、气水两相流流态、排水量),为工程应用提供参考依据。

  1. HYDRAULICS, TUSCARAWAS COUNTY, OHIO, USA

    Data.gov (United States)

    Federal Emergency Management Agency, Department of Homeland Security — Hydraulic data include spatial datasets and data tables necessary for documenting the hydraulic procedures for estimating flood discharges for a flood insurance...

  2. Water Treatment Technology - Hydraulics.

    Science.gov (United States)

    Ross-Harrington, Melinda; Kincaid, G. David

    One of twelve water treatment technology units, this student manual on hydraulics provides instructional materials for three competencies. (The twelve units are designed for a continuing education training course for public water supply operators.) The competencies focus on the following areas: head loss in pipes in series, function loss in…

  3. Water Hydraulic Systems

    DEFF Research Database (Denmark)

    Conrad, Finn

    2005-01-01

    The paper presents research results using IT-Tools for CAD and dynamic modelling, simulation, analysis, and design of water hydraulic actuators for motion control of machines, lifts, cranes and robots. Matlab/Simulink and CATIA are used as IT-Tools. The contributions include results from on-going...

  4. Broadband Spectral Study of Magnetar Bursts

    Science.gov (United States)

    Kirmizibayrak, Demet; Gogus, Ersin; Sasmaz Mus, Sinem; Kaneko, Yuki

    2016-07-01

    Magnetar bursts occur sporadically on random occasions, and every burst-active episode carries unique information about the bursting magnetar. Therefore, in-depth spectral and temporal analyses of each of the magnetar bursts provide new insights into the bursting and radiation mechanisms. There have been a number of studies over the last decade, investigating the spectral and temporal properties of magnetar bursts. The spectra of typical magnetar bursts were generally described with the Comptonized model or the sum of two blackbody functions. However, it was recently shown that the actual spectral nature of these bursts can be conclusively determined if the spectral analysis is performed on a wide energy coverage. We present the results of in-depth systematic broadband (2 - 250 keV) spectral analysis of a large number of bursts originated from three magnetars: SGR 1806-20, SGR 1900+14, and SGR J1550-5418, observed with the Rossi X-ray Timing Explorer.

  5. Amplitude-Modulated Bursting: A Novel Class of Bursting Rhythms

    Science.gov (United States)

    Vo, Theodore; Kramer, Mark A.; Kaper, Tasso J.

    2016-12-01

    We report on the discovery of a novel class of bursting rhythms, called amplitude-modulated bursting (AMB), in a model for intracellular calcium dynamics. We find that these rhythms are robust and exist on open parameter sets. We develop a new mathematical framework with broad applicability to detect, classify, and rigorously analyze AMB. Here we illustrate this framework in the context of AMB in a model of intracellular calcium dynamics. In the process, we discover a novel family of singularities, called toral folded singularities, which are the organizing centers for the amplitude modulation and exist generically in slow-fast systems with two or more slow variables.

  6. SITMILARITY LAW FOR HYDRAULIC DISTORTED MODEL

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    Newton's general similarity criterion was applied to the distorted model. The results for the similarities of gravity force, drag force and pressure force are identical with those derived from relevant differential equations of fluid flow. And the selected limits of the distorted ratio were studied and the simulation of roughness coefficient of distorted model was conducted by means of hydraulic test.

  7. HYDRAULIC CONDUCTIVITY OF THREE GEOSYNTHETIC CLAY LINERS

    Science.gov (United States)

    The hydraulic conductivity of three 2.9 m2 (32 sq ft) geosynthetic clay liners (GCLs) was measured. Tests were performed on individual sheets of the GCLs, on overlapped pieces of GCLs, and on composite liners consisting of a punctured geomembrane overlying a GCL. Hyd...

  8. Thermal-Hydraulic Analysis of an Experimental Reactor Cavity Cooling System with Air. Part I: Experiments; Part II: Separate Effects Tests and Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Corradin, Michael [Univ. of Wisconsin, Madison, WI (United States). Dept. of Engineering Physics; Anderson, M. [Univ. of Wisconsin, Madison, WI (United States). Dept. of Engineering Physics; Muci, M. [Univ. of Wisconsin, Madison, WI (United States). Dept. of Engineering Physics; Hassan, Yassin [Texas A & M Univ., College Station, TX (United States); Dominguez, A. [Texas A & M Univ., College Station, TX (United States); Tokuhiro, Akira [Univ. of Idaho, Moscow, ID (United States); Hamman, K. [Univ. of Idaho, Moscow, ID (United States)

    2014-10-15

    This experimental study investigates the thermal hydraulic behavior and the heat removal performance for a scaled Reactor Cavity Cooling System (RCCS) with air. A quarter-scale RCCS facility was designed and built based on a full-scale General Atomics (GA) RCCS design concept for the Modular High Temperature Gas Reactor (MHTGR). The GA RCCS is a passive cooling system that draws in air to use as the cooling fluid to remove heat radiated from the reactor pressure vessel to the air-cooled riser tubes and discharged the heated air into the atmosphere. Scaling laws were used to preserve key aspects and to maintain similarity. The scaled air RCCS facility at UW-Madison is a quarter-scale reduced length experiment housing six riser ducts that represent a 9.5° sector slice of the full-scale GA air RCCS concept. Radiant heaters were used to simulate the heat radiation from the reactor pressure vessel. The maximum power that can be achieved with the radiant heaters is 40 kW with a peak heat flux of 25 kW per meter squared. The quarter-scale RCCS was run under different heat loading cases and operated successfully. Instabilities were observed in some experiments in which one of the two exhaust ducts experienced a flow reversal for a period of time. The data and analysis presented show that the RCCS has promising potential to be a decay heat removal system during an accident scenario.

  9. PMK-2, the First Integral Thermal-Hydraulics Tests for the Safety Evaluation of VVER-440/213 Nuclear Power Plants

    Directory of Open Access Journals (Sweden)

    Gy. Ézsöl

    2012-01-01

    Full Text Available The PMK-2 facility is a full-pressure thermal-hydraulic model of the primary and partly the secondary circuit of the VVER-type units of Paks NPP. The facility was the first integral-type facility for VVERs. The PMK-2 was followed later by the PACTEL (for VVER-440, the ISB, and PSB for VVER-1000. Since the startup of the facility in 1985, 55 experiments have been performed primarily in international frameworks with the participation of experts from 29 European and overseas countries forming a scientific school to better understand VVER system behaviour and reach a high level of modelling of accident sequences. The ATHLET, CATHARE, and RELAP5 codes have been validated including both qualitative and quantitative assessments. The former was almost exclusively applied to the early phase of validation by integral experiments, while the quantitative assessments have been performed by the Fast Fourier Transform Based Method. Paper gives comprehensive information on the design features of PMK-2 facility with a special respect to the representativeness of phenomena, the experiments performed, and the results of the validation of ATHLET, CATHARE, and RELAP5 codes. Safety significance of the PMK-2 projects is also discussed.

  10. Pedotransfer functions estimating soil hydraulic properties using different soil parameters

    DEFF Research Database (Denmark)

    Børgesen, Christen Duus; Iversen, Bo Vangsø; Jacobsen, Ole Hørbye;

    2008-01-01

    Estimates of soil hydraulic properties using pedotransfer functions (PTF) are useful in many studies such as hydrochemical modelling and soil mapping. The objective of this study was to calibrate and test parametric PTFs that predict soil water retention and unsaturated hydraulic conductivity...... parameters. The PTFs are based on neural networks and the Bootstrap method using different sets of predictors and predict the van Genuchten/Mualem parameters. A Danish soil data set (152 horizons) dominated by sandy and sandy loamy soils was used in the development of PTFs to predict the Mualem hydraulic...... of the hydraulic properties of the studied soils. We found that introducing measured water content as a predictor generally gave lower errors for water retention predictions and higher errors for conductivity predictions. The best of the developed PTFs for predicting hydraulic conductivity was tested against PTFs...

  11. Bursts in intermittent aeolian saltation

    CERN Document Server

    Carneiro, M V; Herrmann, H J

    2014-01-01

    Close to the onset of Aeolian particle transport through saltation we find in wind tunnel experiments a regime of intermittent flux characterized by bursts of activity. Scaling laws are observed in the time delay between each burst and in the measurements of the wind fluctuations at the critical Shields number $\\theta_c$. The time delay between each burst decreases on average with the increase of the Shields number until saltation becomes non-intermittent and the sand flux becomes continuous. A numerical model for saltation including the wind-entrainment from the turbulent fluctuations can reproduce these observations and gives insight about their origin. We present here also for the first time measurements showing that with feeding it becomes possible to sustain intermittent flux even below the threshold $\\theta_c$ for natural saltation initiation.

  12. Two-axis hydraulic joint for high speed, heavy lift robotic operations

    Energy Technology Data Exchange (ETDEWEB)

    Vaughn, M.R.; Robinett, R.D.; Phelan, J.R.; VanZuiden, D.M.

    1994-04-01

    A hydraulically driven universal joint was developed for a heavy lift, high speed nuclear waste remediation application. Each axis is driven by a simple hydraulic cylinder controlled by a jet pipe servovalve. Servovalve behavior is controlled by a force feedback control system, which damps the hydraulic resonance. A prototype single joint robot was built and tested. A two joint robot is under construction.

  13. 污水排海工程的扩散器水力设计 与模型试验研究%Hydraulic design and model test of a diffuser for wastewater discharge

    Institute of Scientific and Technical Information of China (English)

    王春节; 王可钦

    2001-01-01

    通过SZ36-1油田二期终端污水排海工程扩散器的水力设计,比较了扩散器的水力设计的两种计算方法,对水力计算中有关参数及局部阻力系数进行了选用,并通过模型试验进行了验证。表明所用计算方法及其结果是可信的,阻力系数的选取是合适的。%A diffuser of Wastewater discharge des igned for the SZ36-1 oifield, is presented in this paper. The hydraulic design o f the difuser was carried out by two methods. Detail of the design are discussed and a model test is introduced to verify the design.

  14. Hydraulic conductivity of a firn aquifer system in southeast Greenland

    Science.gov (United States)

    Miller, Olivia L.; Solomon, D. Kip; Miège, Clément; Koenig, Lora S.; Forster, Richard R.; Montgomery, Lynn N.; Schmerr, Nicholas; Ligtenberg, Stefan R. M.; Legchenko, Anatoly; Brucker, Ludovic

    2017-05-01

    Some regions of the Greenland ice sheet, where snow accumulation and melt rates are high, currently retain substantial volumes of liquid water within the firn pore space throughout the year. These firn aquifers, found between 10-30 m below the snow surface, may significantly affect sea level rise by storing or draining surface meltwater. The hydraulic gradient and the hydraulic conductivity control flow of meltwater through the firn. Here we describe the hydraulic conductivity of the firn aquifer estimated from slug tests and aquifer tests at six sites located upstream of Helheim Glacier in southeastern Greenland. We conducted slug tests using a novel instrument, a piezometer with a heated tip that melts itself into the ice sheet. Hydraulic conductivity ranges between 2.5x10-5 and 1.1x10-3 m/s. The geometric mean of hydraulic conductivity of the aquifer is 2.7x10-4 m/s with a geometric standard deviation of 1.4 from both depth specific slug tests (analyzed using the Hvorslev method) and aquifer tests during the recovery period. Hydraulic conductivity is relatively consistent between boreholes and only decreases slightly with depth. The hydraulic conductivity of the firn aquifer is crucial for determining flow rates and patterns within the aquifer, which inform hydrologic models of the aquifer, its relation to the broader glacial hydrologic system, and its effect on sea level rise.

  15. Hydraulic Conductivity of a Firn Aquifer in Southeast Greenland

    Directory of Open Access Journals (Sweden)

    Olivia L. Miller

    2017-05-01

    Full Text Available Some regions of the Greenland ice sheet, where snow accumulation and melt rates are high, currently retain substantial volumes of liquid water within the firn pore space throughout the year. These firn aquifers, found between ~10 and 30 m below the snow surface, may significantly affect sea level rise by storing or draining surface meltwater. The hydraulic gradient and the hydraulic conductivity control flow of meltwater through the firn. Here we describe the hydraulic conductivity of the firn aquifer estimated from slug tests and aquifer tests at six sites located upstream of Helheim Glacier in southeastern Greenland. We conducted slug tests using a novel instrument, a piezometer with a heated tip that melts itself into the ice sheet. Hydraulic conductivity ranges between 2.5 × 10−5 and 1.1 × 10−3 m/s. The geometric mean of hydraulic conductivity of the aquifer is 2.7 × 10−4 m/s with a geometric standard deviation of 1.4 from both depth specific slug tests (analyzed using the Hvorslev method and aquifer tests during the recovery period. Hydraulic conductivity is relatively consistent between boreholes and only decreases slightly with depth. The hydraulic conductivity of the firn aquifer is crucial for determining flow rates and patterns within the aquifer, which inform hydrologic models of the aquifer, its relation to the broader glacial hydrologic system, and its effect on sea level rise.

  16. High Redshift Gamma Ray Bursts

    Science.gov (United States)

    Gehrels, Neil

    2012-01-01

    The Swift Observatory has been detecting 100 gamma-ray bursts per year for 7 years and has greatly stimulated the field with new findings. Observations are made of the X-ray and optical afterglow from 1 minute after the burst, continuing for days. GRBs are providing a new tool to study the high redshift universe. Swift has detected several events at z>5 and one at z=9.4 giving information on metallicity, star formation rate and reionization. The talk will present the latest results.

  17. Thermal Balance Analysis of Hydraulic System on a Certain Crane in the Plateau Adaptability Test%某型随车起重机液压系统高原适应性试验热平衡分析

    Institute of Scientific and Technical Information of China (English)

    李世民; 贾宇飞; 陈运兴; 梁媛媛

    2015-01-01

    为科学评价特种车辆随车起重机在高原环境条件下的遂行保障能力,通过分析其液压系统在可靠性试验过程中的热平衡,计算得到了系统达到热平衡时的系统热量以及其随时间历程的变化规律,进而得到了液压系统散热器在高原环境条件下的散热功率约为7.06 kW,液压系统的有效功率约为83%。研究结果对类似保障装置的高原适应性试验及鉴定具有借鉴意义。%For scientifically evaluating the support ability of the special vehicle crane in the plateau envi-ronment,the thermal balance of the hydraulic system is analyzed in the reliability test,the system heat and its changing regularity on the time is calculated when the system achieves thermal equilibrium.Then, it is obtained that the cooling power of the radiator is about 7 .06 kW in the plateau environment and its effective power of the hydraulic system is about 83%.The results provide some reference for the plateau adaptability test as well as appraisement on the similar devices.

  18. Modeling and parameter estimation for hydraulic system of excavator's arm

    Institute of Scientific and Technical Information of China (English)

    HE Qing-hua; HAO Peng; ZHANG Da-qing

    2008-01-01

    A retrofitted electro-bydraulic proportional system for hydraulic excavator was introduced firstly. According to the principle and characteristic of load independent flow distribution(LUDV)system, taking boom hydraulic system as an example and ignoring the leakage of hydraulic cylinder and the mass of oil in it,a force equilibrium equation and a continuous equation of hydraulic cylinder were set up.Based On the flow equation of electro-hydraulic proportional valve, the pressure passing through the valve and the difference of pressure were tested and analyzed.The results show that the difference of pressure does not change with load, and it approximates to 2.0 MPa. And then, assume the flow across the valve is directly proportional to spool displacement andis not influenced by load, a simplified model of electro-hydraulic system was put forward. At the same time, by analyzing the structure and load-bearing of boom instrument, and combining moment equivalent equation of manipulator with rotating law, the estimation methods and equations for such parameters as equivalent mass and bearing force of hydraulic cylinder were set up. Finally, the step response of flow of boom cylinder was tested when the electro-hydraulic proportional valve was controlled by the stepcurrent. Based on the experiment curve, the flow gain coefficient of valve is identified as 2.825×10-4m3/(s·A)and the model is verified.

  19. The IAEA Coordinated Research Program on HTGR Reactor Physics, Thermal-hydraulics and Depletion Uncertainty Analysis: Description of the Benchmark Test Cases and Phases

    Energy Technology Data Exchange (ETDEWEB)

    Frederik Reitsma; Gerhard Strydom; Bismark Tyobeka; Kostadin Ivanov

    2012-10-01

    The continued development of High Temperature Gas Cooled Reactors (HTGRs) requires verification of design and safety features with reliable high fidelity physics models and robust, efficient, and accurate codes. The uncertainties in the HTR analysis tools are today typically assessed with sensitivity analysis and then a few important input uncertainties (typically based on a PIRT process) are varied in the analysis to find a spread in the parameter of importance. However, one wish to apply a more fundamental approach to determine the predictive capability and accuracies of coupled neutronics/thermal-hydraulics and depletion simulations used for reactor design and safety assessment. Today there is a broader acceptance of the use of uncertainty analysis even in safety studies and it has been accepted by regulators in some cases to replace the traditional conservative analysis. Finally, there is also a renewed focus in supplying reliable covariance data (nuclear data uncertainties) that can then be used in uncertainty methods. Uncertainty and sensitivity studies are therefore becoming an essential component of any significant effort in data and simulation improvement. In order to address uncertainty in analysis and methods in the HTGR community the IAEA launched a Coordinated Research Project (CRP) on the HTGR Uncertainty Analysis in Modelling early in 2012. The project is built on the experience of the OECD/NEA Light Water Reactor (LWR) Uncertainty Analysis in Best-Estimate Modelling (UAM) benchmark activity, but focuses specifically on the peculiarities of HTGR designs and its simulation requirements. Two benchmark problems were defined with the prismatic type design represented by the MHTGR-350 design from General Atomics (GA) while a 250 MW modular pebble bed design, similar to the INET (China) and indirect-cycle PBMR (South Africa) designs are also included. In the paper more detail on the benchmark cases, the different specific phases and tasks and the latest

  20. Hydraulic manipulator design, analysis, and control at Oak Ridge National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Kress, R.L.; Jansen, J.F. [Oak Ridge National Lab., TN (United States). Robotics and Process Systems Div.; Love, L.J. [Oak Ridge Inst. for Science and Education, TN (United States); Basher, A.M.H. [South Carolina State Univ., Orangeburg, SC (United States)

    1996-09-01

    To meet the increased payload capacities demanded by present-day tasks, manipulator designers have turned to hydraulics as a means of actuation. Hydraulics have always been the actuator of choice when designing heavy-life construction and mining equipment such as bulldozers, backhoes, and tunneling devices. In order to successfully design, build, and deploy a new hydraulic manipulator (or subsystem) sophisticated modeling, analysis, and control experiments are usually needed. To support the development and deployment of new hydraulic manipulators Oak Ridge National Laboratory (ORNL) has outfitted a significant experimental laboratory and has developed the software capability for research into hydraulic manipulators, hydraulic actuators, hydraulic systems, modeling of hydraulic systems, and hydraulic controls. The hydraulics laboratory at ORNL has three different manipulators. First is a 6-Degree-of-Freedom (6-DoF), multi-planer, teleoperated, flexible controls test bed used for the development of waste tank clean-up manipulator controls, thermal studies, system characterization, and manipulator tracking. Finally, is a human amplifier test bed used for the development of an entire new class of teleoperated systems. To compliment the hardware in the hydraulics laboratory, ORNL has developed a hydraulics simulation capability including a custom package to model the hydraulic systems and manipulators for performance studies and control development. This paper outlines the history of hydraulic manipulator developments at ORNL, describes the hydraulics laboratory, discusses the use of the equipment within the laboratory, and presents some of the initial results from experiments and modeling associated with these hydraulic manipulators. Included are some of the results from the development of the human amplifier/de-amplifier concepts, the characterization of the thermal sensitivity of hydraulic systems, and end-point tracking accuracy studies. Experimental and analytical

  1. Directional hydraulic fracturing to control hard-roof rockburst in coal mines

    Institute of Scientific and Technical Information of China (English)

    Fan Jun; Dou Linming; He Hu; Du Taotao; Zhang Shibin; Gui Bing; Sun Xinglin

    2012-01-01

    Hard roof is the main factor that induces rock-burst.In view of the present obvious weakness of control measures for hard roof rockburst in domestic collieries,the mechanism and field application of directional hydraulic fracturing technology for rock-burst prevention have been investigated in this paper using theoretical analysis and numerical simulation.The results show that the weighting span of the main roof and the released kinetic energy as well as the total elastic energy decreased greatly after the directional fracturing of hard roof with the mining progression,thereby reducing the rockburst hazard degree to coal body.The directional hydraulic fracturing technology was carried out in 6305 working face of Jisan Coal Mine to prevent rockburst.Field practices have proved that this technology is much simpler and safer to operate with better prevention effect compared with blasting.By optimizing the operation procedures and developing a new technology of automated high-pressure delivery pipe,the maximum fracturing radius now reaches more than 9 m and the borehole depth exceeds 20 m.Additionally,drilling cutting method was applied to monitor the stress of the coal mass before and after the fracturing,and the drill cuttings dropped significantly which indicates that the burst prevention effect of directional hydraulic fracturing technology is very remarkable.The research results of this paper have laid a theoretical and practical foundation for the widespread application of the directional hydraulic fracturing technology in China.

  2. Remotely Adjustable Hydraulic Pump

    Science.gov (United States)

    Kouns, H. H.; Gardner, L. D.

    1987-01-01

    Outlet pressure adjusted to match varying loads. Electrohydraulic servo has positioned sleeve in leftmost position, adjusting outlet pressure to maximum value. Sleeve in equilibrium position, with control land covering control port. For lowest pressure setting, sleeve shifted toward right by increased pressure on sleeve shoulder from servovalve. Pump used in aircraft and robots, where hydraulic actuators repeatedly turned on and off, changing pump load frequently and over wide range.

  3. 基于某型计程仪测试系统要求的高精度液压发生装置研究%Study on Precision-machined Hydraulic Producing Instrument Based on Certain Log Testing System

    Institute of Scientific and Technical Information of China (English)

    吴永明; 闻琦

    2012-01-01

    A warship imported in 90's is entering repair cycle.The ship's equipments need to be executed mending intermediately,however,there aren't any necessary maintenance instruction documents about the ЛГП hydraulic pressure log which is one important component of the naval ship's navigation system.There is also a lack of high precision testing equipments which are available for the in-factory dynamic repair.Meanwhile,the functional test for amplificatory circuitry board,debugging means and relational formulas for pressure sense organ ripple pipe can't be acquired.To meet the requirements of in-factory repairing the log,it's necessary to develop a testing system which may precisely control hydraulic pressure.The specific requirements include generating-10KPa-100KPa dynamic-static pressure difference with 4MPa hydraulic pressure,keeping the precision in the scope of ±0.2KPa.Since the general existing solution can't meet the precision requirement,the study and design of a high precision hydraulic generator described in the paper are significant for repairing the log in the factory.%我国90年代从国外引进的某型艇已进入首轮中修修理周期,但作为舰艇导航系统重要自主导航装备之一的ЛГП水压计程仪既无装备中修指南,国内也缺乏该水压计程仪内场动态高精度测试工装设备、放大器线路板功能测试及计程仪压力敏感部件波纹管调试手段。为完成该计程仪内场中修调试,需研制一套测试系统对液压进行精确控制,要求在最大产生4MPa液压力的同时能够产生-10kPa至100kPa范围内的动静压差,精度为±0.2kPa。目前,采用常规的液压系统设计方案不能够满足上述精度要求,因此本文所进行的高精度液压发生装置的研究和设计,对满足计程仪在工厂内顺利完成中修任务具有重要意义。

  4. Undular Hydraulic Jump

    Directory of Open Access Journals (Sweden)

    Oscar Castro-Orgaz

    2015-04-01

    Full Text Available The transition from subcritical to supercritical flow when the inflow Froude number Fo is close to unity appears in the form of steady state waves called undular hydraulic jump. The characterization of the undular hydraulic jump is complex due to the existence of a non-hydrostatic pressure distribution that invalidates the gradually-varied flow theory, and supercritical shock waves. The objective of this work is to present a mathematical model for the undular hydraulic jump obtained from an approximate integration of the Reynolds equations for turbulent flow assuming that the Reynolds number R is high. Simple analytical solutions are presented to reveal the physics of the theory, and a numerical model is used to integrate the complete equations. The limit of application of the theory is discussed using a wave breaking condition for the inception of a surface roller. The validity of the mathematical predictions is critically assessed using physical data, thereby revealing aspects on which more research is needed

  5. 全液压山地手扶式苜蓿刈割压扁机设计与试验%A Kind of Full Hydraulic Mountains Alfalfa Cutting and Flattening Machine Design and Test Study

    Institute of Scientific and Technical Information of China (English)

    赵建柱; 孙凤涛; 陈宏伟; 孙佳; 王德成

    2017-01-01

    为适应我国山坡、丘陵地带苜蓿收获特殊需求,提高苜蓿收获机械作业操作灵活性和安全性,提出了一款山地手扶式苜蓿刈割压扁机。该机采用全液压驱动,整机液压系统由行走驱动回路、工作装置升降控制回路及工作装置驱动回路3部分组成,可实现自走、工作装置升降和刈割压扁作业;工作装置升降机构采用平行四连杆机构,以保证工作装置升降过程中割刀刀盘倾角不变。同时,进行了样机试制与田间性能试验,试验表明:整机能够有效地实现苜蓿的刈割、压扁作业,爬坡度可达30%,行驶速度可达5km/h,能够实现单边制动转向及原地转向等功能,满足山坡、丘陵地带苜蓿收获的需求。%In order to meet the requirements of alfalfa harvesting on the mountain and hill environment, this paper propo-ses a kind of full hydraulic mountains hand alfalfa cutting and flattening machinery to improve its operation flexibility and safety. The machine adopts full hydraulic pressure drive with hydraulic system,which includes three parts, walking cir-cuit, working device lifting control circuit and driving circuit, to cut and flat the alfalfa, drive the machine and lift the working device. We have produced the prototype machinery and execute the tests to verify its working performance in the alfalfa field. The results indicate that the prototype can effectively complete the alfalfa cutting and flattening operation. The maximum climbable gradient is 30%,and the walking speed is up to 5 km/h. Unilateral braking steering and pivot steering is also achieved. Moreover,it can make flattening operation flexible when the machinery cut the alfalfa. So this alfalfa cutting and flattening machinery can work on the mountains and hills to harvest alfalfa.

  6. On the Hydraulics of Flowing Horizontal Wells

    Science.gov (United States)

    Bian, A.; Zhan, H.

    2003-12-01

    A flowing horizontal well is a special type of horizontal well that does not have pumping/injecting facility. The discharge rate of a flowing horizontal well is controlled by the hydraulic gradient between the aquifer and the well and it generally varies with time if the hydraulic head of the aquifer is transient. This type of well has been used in landslide control, mining dewatering, water table control, underground water transportation through a horizontal tunnel, agricultural water drainage, and other applications. Flowing horizontal wells have quite different hydrodynamic characteristics from horizontal wells with fixed pumping or injecting rates because their discharge rates are functions of the aquifer hydraulic heads (Zhan et al, 2001; Zhan and Zlotnik, 2002). Hydraulics of flowing horizontal wells have rarely been studied although the hydraulics of flowing vertical wells have been extensively investigated before. The purpose of this paper is to obtain analytical solutions of groundwater flow to a flowing horizontal-well in a confined aquifer, in a water table aquifer without precipitation, and in a water table aquifer with precipitation. The functions of the flowing horizontal well discharge rates versus time will be obtained under above mentioned different aquifer conditions. The relationships of the aquifer hydraulic heads versus the discharge rates of the well will be investigated. The rate of water table decline due to the dewatering of the well will also be computed, and this solution is particularly useful for landslide control and mining dewatering. The theoretical solutions will be compared with results of experiments that will be conducted in the hydrological laboratory at Texas A&M University. Reference: Zhan, H., Wang, L.V., and Park, E, On the horizontal well pumping tests in the anisotropic confined aquifers, J. hydrol., 252, 37-50, 2001. Zhan, H., and Zlotnik, V. A., Groundwater flow to a horizontal or slanted well in an unconfined aquifer

  7. FERMIGBRST - Fermi GBM Burst Catalog

    Data.gov (United States)

    National Aeronautics and Space Administration — This table lists all of the triggers observed by a subset of the 14 GBM detectors (12 NaI and 2 BGO) which have been classified as gamma-ray bursts (GRBs). Note that...

  8. Microscopic characteristics of burst coal seams

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, H.; Wang, C. [Shandong University of Science and Technology (China)

    2000-08-01

    Based on the analytical results of coal samples with microscope and scanning electron microscope, the paper explains the petrographic characteristics and microscopic depredation of burst coal. Quantitative analysis on the components and microstructures of the burst coal is conducted. The influence of the microscopic characteristics on coal burst is discussed. For coal seams with burst tendency, it has provided the necessary forecasting parameters. 2 refs., 1 fig., 2 tabs.

  9. Millisecond extragalactic radio bursts as magnetar flares

    CERN Document Server

    Popov, S B

    2013-01-01

    Properties of the population of millisecond extragalactic radio bursts discovered by Thornton et al. (2013) are in good correspondence with the hypothesis that such events are related to hyperflares of magnetars, as was proposed by us after the first observation of an extragalactic millisecond radio burst by Lorimer et al. (2007). We also point that some of multiple millisecond radio bursts from M31 discovered by Rubio-Herrera et al. (2013) also can be related to weaker magnetar bursts.

  10. Microfluidic parallel circuit for measurement of hydraulic resistance.

    Science.gov (United States)

    Choi, Sungyoung; Lee, Myung Gwon; Park, Je-Kyun

    2010-08-31

    We present a microfluidic parallel circuit that directly compares the test channel of an unknown hydraulic resistance with the reference channel with a known resistance, thereby measuring the unknown resistance without any measurement setup, such as standard pressure gauges. Many of microfluidic applications require the precise transport of fluid along a channel network with complex patterns. Therefore, it is important to accurately characterize and measure the hydraulic resistance of each channel segment, and determines whether the device principle works well. However, there is no fluidic device that includes features, such as the ability to diagnose microfluidic problems by measuring the hydraulic resistance of a microfluidic component in microscales. To address the above need, we demonstrate a simple strategy to measure an unknown hydraulic resistance, by characterizing the hydraulic resistance of microchannels with different widths and defining an equivalent linear channel of a microchannel with repeated patterns of a sudden contraction and expansion.

  11. Investigation of Valve Plate in Water Hydraulic Axial Piston Motor

    Institute of Scientific and Technical Information of China (English)

    聂松林; 李壮云; 等

    2002-01-01

    This paper has introduced the developments of water hydraulic axial piston equipments.According to the effects of physicochemical properties of water on water hydraulic components,a novel valve plate for water hydraulic axial motor has been put forward,whose moment exerted by the fluid field between valve plate and bearing plate is balanced entirely.The material screening experiment of valve plate is done on the test rig.Through numerical simulation the effects of some geometry parameters on the performance of water hydraulic motor have been studied.The silencing grooves on the valve plate in water hydraulic motor can reduce the pressure shock and the occurrence of cavitation effectively.It is evident that the appropriate structure should change the wear status between matching paris and reduces the wear and specific pressure of the matching pairs.The specimen with the new type valve plate is used in a tool system.

  12. COMPUTATIONAL FLOW RATE FEEDBACK AND CONTROL METHOD IN HYDRAULIC ELEVATORS

    Institute of Scientific and Technical Information of China (English)

    Xu Bing; Ma Jien; Lin Jianjie

    2005-01-01

    The computational flow rate feedback and control method, which can be used in proportional valve controlled hydraulic elevators, is discussed and analyzed. In a hydraulic elevator with this method, microprocessor receives pressure information from the pressure transducers and computes the flow rate through the proportional valve based on pressure-flow conversion real time algorithm. This hydraulic elevator is of lower cost and energy consumption than the conventional closed loop control hydraulic elevator whose flow rate is measured by a flow meter. Experiments are carried out on a test rig which could simulate the load of hydraulic elevator. According to the experiment results, the means to modify the pressure-flow conversion algorithm are pointed out.

  13. Hydraulic System Design of Hydraulic Actuators for Large Butterfly Valves

    OpenAIRE

    HUANG, Ye; Liu, Changsheng; Shiongur Bamed

    2014-01-01

    Hydraulic control systems of butterfly valves are presently valve-controlled and pump-controlled. Valve-controlled hydraulic systems have serious power loss and generate much heat during throttling. Pump-controlled hydraulic systems have no overflow or throttling losses but are limited in the speed adjustment of the variable-displacement pump, generate much noise, pollute the environment, and have motor power that does not match load requirements, resulting in low efficiency under...

  14. Hydraulic analysis of cell-network treatment wetlands

    Science.gov (United States)

    Wang, Huaguo; Jawitz, James W.

    2006-11-01

    SummaryWhen individual cells of a multiple-cell treatment wetland are hydraulically connected, the wetland has a cell-network structure. The hydraulic performance of treatment wetlands is often characterized using tracer residence time distributions (RTDs) measured between the wetland inlet and outlet, such that the wetland is considered as a single hydraulic unit, regardless of the extent of networking between individual internal cells. This work extends the single hydraulic unit approach to enable the specification of moments and RTD parameters for individual cells, or clusters of cells, within the cell-network based on inert tracer tests with injection only at the network inlet. Hydraulic performance is quantified in terms of hydraulic efficiency and travel time dimensionless variance using both the method of moments and RTD modeling. Cell-network analysis was applied to a case study from the Orlando Easterly Wetland (OEW), demonstrating the improvement in hydraulic performance of individual wetland cells following wetland restoration activities. Furthermore, cell-network analysis indicated that the location of water quality sampling station locations within the cell network can significantly affect the accuracy of pollutant removal effectiveness estimation when the individual sample station RTD does not represent the hydraulic unit RTD. At the OEW, it was determined that historical nutrient removal effectiveness estimation may be underestimated for one area and overestimated for another, and recommendations were provided for sample station locations to minimize future performance estimation errors.

  15. Efficiency limit factor analysis for the Francis-99 hydraulic turbine

    Science.gov (United States)

    Zeng, Y.; Zhang, L. X.; Guo, J. P.; Guo, Y. K.; Pan, Q. L.; Qian, J.

    2017-01-01

    The energy loss in hydraulic turbine is the most direct factor that affects the efficiency of the hydraulic turbine. Based on the analysis theory of inner energy loss of hydraulic turbine, combining the measurement data of the Francis-99, this paper calculates characteristic parameters of inner energy loss of the hydraulic turbine, and establishes the calculation model of the hydraulic turbine power. Taken the start-up test conditions given by Francis-99 as case, characteristics of the inner energy of the hydraulic turbine in transient and transformation law are researched. Further, analyzing mechanical friction in hydraulic turbine, we think that main ingredients of mechanical friction loss is the rotation friction loss between rotating runner and water body, and defined as the inner mechanical friction loss. The calculation method of the inner mechanical friction loss is given roughly. Our purpose is that explore and research the method and way increasing transformation efficiency of water flow by means of analysis energy losses in hydraulic turbine.

  16. Hydraulic System Design of Hydraulic Actuators for Large Butterfly Valves

    Directory of Open Access Journals (Sweden)

    Ye HUANG

    2014-09-01

    Full Text Available Hydraulic control systems of butterfly valves are presently valve-controlled and pump-controlled. Valve-controlled hydraulic systems have serious power loss and generate much heat during throttling. Pump-controlled hydraulic systems have no overflow or throttling losses but are limited in the speed adjustment of the variable-displacement pump, generate much noise, pollute the environment, and have motor power that does not match load requirements, resulting in low efficiency under light loads and wearing of the variable-displacement pump. To overcome these shortcomings, this article designs a closed hydraulic control system in which an AC servo motor drives a quantitative pump that controls a spiral swinging hydraulic cylinder, and analyzes and calculates the structure and parameters of a spiral swinging hydraulic cylinder. The hydraulic system adjusts the servo motor’s speed according to the requirements of the control system, and the motor power matches the power provided to components, thus eliminating the throttling loss of hydraulic circuits. The system is compact, produces a large output force, provides stable transmission, has a quick response, and is suitable as a hydraulic control system of a large butterfly valve.

  17. An Integrated View of Whole-Tree Hydraulic Architecture. Does Stomatal or Hydraulic Conductance Determine Whole Tree Transpiration?

    Directory of Open Access Journals (Sweden)

    Juan Rodríguez-Gamir

    Full Text Available Hydraulic conductance exerts a strong influence on many aspects of plant physiology, namely: transpiration, CO2 assimilation, growth, productivity or stress response. However we lack full understanding of the contribution of root or shoot water transport capacity to the total water balance, something which is difficult to study in trees. Here we tested the hypothesis that whole plant hydraulic conductance modulates plant transpiration using two different seedlings of citrus rootstocks, Poncirus trifoliata (L. Raf. and Cleopatra mandarin (Citrus reshni Hort ex Tan.. The two genotypes presented important differences in their root or shoot hydraulic conductance contribution to whole plant hydraulic conductance but, even so, water balance proved highly dependent on whole plant conductance. Further, we propose there is a possible equilibrium between root and shoot hydraulic conductance, similar to that between shoot and root biomass production, which could be related with xylem anatomy.

  18. An Integrated View of Whole-Tree Hydraulic Architecture. Does Stomatal or Hydraulic Conductance Determine Whole Tree Transpiration?

    Science.gov (United States)

    Rodríguez-Gamir, Juan; Primo-Millo, Eduardo; Forner-Giner, María Ángeles

    2016-01-01

    Hydraulic conductance exerts a strong influence on many aspects of plant physiology, namely: transpiration, CO2 assimilation, growth, productivity or stress response. However we lack full understanding of the contribution of root or shoot water transport capacity to the total water balance, something which is difficult to study in trees. Here we tested the hypothesis that whole plant hydraulic conductance modulates plant transpiration using two different seedlings of citrus rootstocks, Poncirus trifoliata (L.) Raf. and Cleopatra mandarin (Citrus reshni Hort ex Tan.). The two genotypes presented important differences in their root or shoot hydraulic conductance contribution to whole plant hydraulic conductance but, even so, water balance proved highly dependent on whole plant conductance. Further, we propose there is a possible equilibrium between root and shoot hydraulic conductance, similar to that between shoot and root biomass production, which could be related with xylem anatomy.

  19. DLC coatings for hydraulic applications

    Institute of Scientific and Technical Information of China (English)

    Luca NOBILI; Luca MAGAGNIN

    2009-01-01

    Replacement of lubricating oils with water or low-viscosity fluids is highly desirable in many industrial fields, on account of the environmental and economical advantages. Low lubricity of water might be insufficient for proper operation of hydraulic components, and diamond-like carbon(DLC) coatings are very attractive as solid lubricant films. A remote-plasma PACVD process was utilized to deposit hydrogenated DLC coatings (a-C:H) on different substrates. Microindentation measurements show that the coating hardness is around 35 GPa. Tribological behavior was evaluated by block-on-ring tests performed in water and water with alumina. The wear rate was calculated after measuring the wear volume by a laser profilemeter. Morphological and compositional analysis of the wear tracks reveal that coating failure may occur by abrasive wear or delamination, depending on the substrate properties. Hard and smooth substrates give the best results and dispersed alumina particles increase the wear rate.

  20. Assimilation of temperature and hydraulic gradients for quantifying the spatial variability of streambed hydraulics

    Science.gov (United States)

    Huang, Xiang; Andrews, Charles B.; Liu, Jie; Yao, Yingying; Liu, Chuankun; Tyler, Scott W.; Selker, John S.; Zheng, Chunmiao

    2016-08-01

    Understanding the spatial and temporal characteristics of water flux into or out of shallow aquifers is imperative for water resources management and eco-environmental conservation. In this study, the spatial variability in the vertical specific fluxes and hydraulic conductivities in a streambed were evaluated by integrating distributed temperature sensing (DTS) data and vertical hydraulic gradients into an ensemble Kalman filter (EnKF) and smoother (EnKS) and an empirical thermal-mixing model. The formulation of the EnKF/EnKS assimilation scheme is based on a discretized 1D advection-conduction equation of heat transfer in the streambed. We first systematically tested a synthetic case and performed quantitative and statistical analyses to evaluate the performance of the assimilation schemes. Then a real-world case was evaluated to calculate assimilated specific flux. An initial estimate of the spatial distributions of the vertical hydraulic gradients was obtained from an empirical thermal-mixing model under steady-state conditions using a constant vertical hydraulic conductivity. Then, this initial estimate was updated by repeatedly dividing the assimilated specific flux by estimates of the vertical hydraulic gradients to obtain a refined spatial distribution of vertical hydraulic gradients and vertical hydraulic conductivities. Our results indicate that optimal parameters can be derived with fewer iterations but greater simulation effort using the EnKS compared with the EnKF. For the field application in a stream segment of the Heihe River Basin in northwest China, the average vertical hydraulic conductivities in the streambed varied over three orders of magnitude (5 × 10-1 to 5 × 102 m/d). The specific fluxes ranged from near zero (qz < ±0.05 m/d) to ±1.0 m/d, while the vertical hydraulic gradients were within the range of -0.2 to 0.15 m/m. The highest and most variable fluxes occurred adjacent to a debris-dam and bridge pier. This phenomenon is very likely

  1. Study on Monitoring Rock Burst through Drill Pipe Torque

    Directory of Open Access Journals (Sweden)

    Zhonghua Li

    2015-01-01

    Full Text Available This paper presents a new method to identify the danger of rock burst from the response of drill pipe torque during drilling process to overcome many defects of the conventional volume of drilled coal rubble method. It is based on the relationship of rock burst with coal stress and coal strength. Through theoretic analysis, the change mechanism of drill pipe torque and the relationship of drill pipe torque with coal stress, coal strength, and drilling speed are investigated. In light of the analysis, a new device for testing drill pipe torque is developed and a series of experiments is performed under different conditions; the results show that drill pipe torque linearly increases with the increase of coal stress and coal strength; the faster the drilling speed, the larger the drill pipe torque, and vice versa. When monitoring rock burst by drill pipe torque method, the index of rock burst is regarded as a function in which coal stress index and coal strength index are principal variables. The results are important for the forecast of rock burst in coal mine.

  2. An internally consistent gamma ray burst time history phenomenology

    Science.gov (United States)

    Cline, T. L.

    1985-01-01

    A phenomenology for gamma ray burst time histories is outlined. Order of their generally chaotic appearance is attempted, based on the speculation that any one burst event can be represented above 150 keV as a superposition of similarly shaped increases of varying intensity. The increases can generally overlap, however, confusing the picture, but a given event must at least exhibit its own limiting characteristic rise and decay times if the measurements are made with instruments having adequate temporal resolution. Most catalogued observations may be of doubtful or marginal utility to test this hypothesis, but some time histories from Helios-2, Pioneer Venus Orbiter and other instruments having one-to several-millisecond capabilities appear to provide consistency. Also, recent studies of temporally resolved Solar Maximum Mission burst energy spectra are entirely compatible with this picture. The phenomenology suggested here, if correct, may assist as an analytic tool for modelling of burst processes and possibly in the definition of burst source populations.

  3. Temporal and spacial evolution of bursts in creep rupture.

    Science.gov (United States)

    Danku, Zsuzsa; Kun, Ferenc

    2013-08-23

    We investigate the temporal and spacial evolution of single bursts and their statistics emerging in heterogeneous materials under a constant external load. Based on a fiber bundle model we demonstrate that when the load redistribution is localized along a propagating crack front, the average temporal shape of pulses has a right-handed asymmetry; however, for long range interaction a symmetric shape with parabolic functional form is obtained. The pulse shape and spatial evolution of bursts proved to be correlated, which can be exploited in materials' testing. The probability distribution of the size and duration of bursts have power law behavior with a crossover to higher exponents as the load is lowered. The crossover emerges due to the competition of the slow and fast modes of local breaking being dominant at low and high loads, respectively.

  4. Hydraulic mining method

    Science.gov (United States)

    Huffman, Lester H.; Knoke, Gerald S.

    1985-08-20

    A method of hydraulically mining an underground pitched mineral vein comprising drilling a vertical borehole through the earth's lithosphere into the vein and drilling a slant borehole along the footwall of the vein to intersect the vertical borehole. Material is removed from the mineral vein by directing a high pressure water jet thereagainst. The resulting slurry of mineral fragments and water flows along the slant borehole into the lower end of the vertical borehole from where it is pumped upwardly through the vertical borehole to the surface.

  5. Spinning hydraulic jump

    Science.gov (United States)

    Abderrahmane, Hamid; Kasimov, Aslan

    2013-11-01

    We report an experimental observation of a new symmetry breaking of circular hydraulic jump into a self-organized structure that consists of a spinning polygonal jump and logarithmic-spiral waves of fluid elevation downstream. The waves are strikingly similar to spiral density waves in galaxies. The fluid flow exhibits counterparts of salient morphological features of galactic flows, in particular the outflow from the center, jets, circum-nuclear rings, gas inflows toward the galactic center, and vortices. The hydrodynamic instability revealed here may have a counterpart that plays a role in the formation and sustainability of spiral arms in galaxies.

  6. Spatial variability in streambed hydraulic conductivity of contrasting stream morphologies

    DEFF Research Database (Denmark)

    Sebök, Éva; Calvache, Carlos Duque; Engesgaard, Peter Knudegaard;

    2015-01-01

    Streambed hydraulic conductivity is one of the main factors controlling variability in surface water-groundwater interactions, but only few studies aim at quantifying its spatial and temporal variability in different stream morphologies. Streambed horizontal hydraulic conductivities (Kh) were...... therefore determined from in-stream slug tests, vertical hydraulic conductivities (Kv) were calculated with in-stream permeameter tests and hydraulic heads were measured to obtain vertical head gradients at eight transects, each comprising five test locations, in a groundwater-dominated stream. Seasonal...... small-scale measurements were taken in December 2011 and August 2012, both in a straight stream channel with homogeneous elevation and downstream of a channel meander with heterogeneous elevation. All streambed attributes showed large spatial variability. Kh values were the highest at the depositional...

  7. Experimental Report for Thermal Hydraulic Behavior During Startup, Power Change and MCP Transient Operation by using the High Temperature/High Pressure Test Facility(VISTA)

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ki Yong; Park, Hyun Sik; Cho, Seok; Lee, Sung Jae; Choi, Nam Hyun; Min, Kyong Ho; Song, Chul Hwa; Park, Chun Kyong; Chung, Moon Ki

    2005-07-15

    The VISTA (Experimental Verification by Integral Simulation of Transients and Accidents) is an experimental facility to verify the performance and safety issues of the SMART-P (Pilot plant of the System-integrated Modular Advanced Reactor). The basic design of the SMART-P has been completed by KAERI. The present report describes experimental test results for performance test items, including heatup, power change, MCP transient, and natural circulation operations by using the VISTA facility.

  8. Spindle Bursts in Neonatal Rat Cerebral Cortex

    Directory of Open Access Journals (Sweden)

    Jenq-Wei Yang

    2016-01-01

    Full Text Available Spontaneous and sensory evoked spindle bursts represent a functional hallmark of the developing cerebral cortex in vitro and in vivo. They have been observed in various neocortical areas of numerous species, including newborn rodents and preterm human infants. Spindle bursts are generated in complex neocortical-subcortical circuits involving in many cases the participation of motor brain regions. Together with early gamma oscillations, spindle bursts synchronize the activity of a local neuronal network organized in a cortical column. Disturbances in spindle burst activity during corticogenesis may contribute to disorders in cortical architecture and in the activity-dependent control of programmed cell death. In this review we discuss (i the functional properties of spindle bursts, (ii the mechanisms underlying their generation, (iii the synchronous patterns and cortical networks associated with spindle bursts, and (iv the physiological and pathophysiological role of spindle bursts during early cortical development.

  9. Spindle Bursts in Neonatal Rat Cerebral Cortex.

    Science.gov (United States)

    Yang, Jenq-Wei; Reyes-Puerta, Vicente; Kilb, Werner; Luhmann, Heiko J

    2016-01-01

    Spontaneous and sensory evoked spindle bursts represent a functional hallmark of the developing cerebral cortex in vitro and in vivo. They have been observed in various neocortical areas of numerous species, including newborn rodents and preterm human infants. Spindle bursts are generated in complex neocortical-subcortical circuits involving in many cases the participation of motor brain regions. Together with early gamma oscillations, spindle bursts synchronize the activity of a local neuronal network organized in a cortical column. Disturbances in spindle burst activity during corticogenesis may contribute to disorders in cortical architecture and in the activity-dependent control of programmed cell death. In this review we discuss (i) the functional properties of spindle bursts, (ii) the mechanisms underlying their generation, (iii) the synchronous patterns and cortical networks associated with spindle bursts, and (iv) the physiological and pathophysiological role of spindle bursts during early cortical development.

  10. 46 CFR 28.880 - Hydraulic equipment.

    Science.gov (United States)

    2010-10-01

    ... hydraulic equipment and the adjacent work area. Protection shall be afforded to the operator of hydraulic... 46 Shipping 1 2010-10-01 2010-10-01 false Hydraulic equipment. 28.880 Section 28.880 Shipping... INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.880 Hydraulic equipment. (a) Each hydraulic system must...

  11. On the possible role of thermal radiation in containment thermal–hydraulics experiments by the example of CFD analysis of TOSQAN T114 air–He test

    Energy Technology Data Exchange (ETDEWEB)

    Filippov, A.S.; Grigoryev, S.Yu. [Nuclear Safety Institute of the Russian Academy of Sciences, Moscow (Russian Federation); Moscow Institute of Physics and Technology (Russian Federation); Tarasov, O.V. [Nuclear Safety Institute of the Russian Academy of Sciences, Moscow (Russian Federation)

    2016-12-15

    Highlights: • Neglecting by heat radiation in simulation of containment tests may cause discrepancies. • To show that, heat exchange in T114 air-helium test was analyzed in different ways. • Effect of thermal radiation on local temperature was numerically obtained in air with ∼1% steam content. • Model of gas-structure heat exchange in containment should include heat radiation. - Abstract: One of the experiments of ERCOSAM–SAMARA (E–S) projects (TOSQAN T114) is examined from the viewpoint of the radiative heat transfer (RHT) contribution to the overall heat exchange. E–S projects and T114 test were focused on investigation of light gas stratification in severe accident containment atmosphere and stratification break-up after the activation of mitigation systems. The first from two phases of T114 test is considered during which helium is quasistatically injected into the upper part of the TOSQAN vessel having isothermal walls and initially filled by air. The developing free convection removes most of the heat acquired, but not all. Thus stable local deviations in calculated temperatures were obtained in simulations that were interpreted as the deficiencies of the physical heat-transfer model. The modeling of RHT was included in full CFD simulation that resulted in a better agreement in local temperatures. The results of comparative calculations performed without/with RHT modeling are described in the paper. The RHT model implemented in the used CFD code (ANSYS FLUENT) was tested on known analytical solutions. The RHT contribution in T114 test was also estimated analytically to demonstrate independently that it may be noticeable in this experiment. The same estimations may be valid for stagnant zones of severe accident containment. All that shows the need in further detailing of the role of RHT in gas-structure heat exchange: as for interpretation of some containment tests performed in pressure vessel as for containment modeling.

  12. Applied hydraulic transients

    CERN Document Server

    Chaudhry, M Hanif

    2014-01-01

    This book covers hydraulic transients in a comprehensive and systematic manner from introduction to advanced level and presents various methods of analysis for computer solution. The field of application of the book is very broad and diverse and covers areas such as hydroelectric projects, pumped storage schemes, water-supply systems, cooling-water systems, oil pipelines and industrial piping systems. Strong emphasis is given to practical applications, including several case studies, problems of applied nature, and design criteria. This will help design engineers and introduce students to real-life projects. This book also: ·         Presents modern methods of analysis suitable for computer analysis, such as the method of characteristics, explicit and implicit finite-difference methods and matrix methods ·         Includes case studies of actual projects ·         Provides extensive and complete treatment of governed hydraulic turbines ·         Presents design charts, desi...

  13. Development of A Hydraulic Drive for a novel Diesel-Hydraulic system for Large commercial Vehicles

    DEFF Research Database (Denmark)

    Stecki, J. S.; Conrad, Finn; Matheson, P.

    2002-01-01

    The objectives and results of the research project Hybrid Diesel-Hydraulic System for Large commercial vehicles, e.g. urban freight delivery, buses or garbage trucks. The paper presents and discusses the research and development of the system, modelling approach and results from preliminary...... performance tests on a 10 ton vehicle....

  14. On the Dynamic Measurements of Hydraulic Characteristics

    Science.gov (United States)

    Hasmatuchi, Vlad; Bosioc, Alin; Münch-Alligné, Cécile

    2016-11-01

    The present work introduces the implementation and validation of a faster method to measure experimentally the efficiency characteristics of hydraulic turbomachines at a model scale on a test rig. The case study is represented by a laboratory prototype of an in-line axial microturbine for water supply networks. The 2.65 kW one-stage variable speed turbine, composed by one upstream 5-blade runner followed by one counter-rotating downstream 7-blade runner, has been installed on the HES-SO Valais/Wallis universal test rig dedicated to assess performances of small hydraulic machinery following the IEC standard recommendations. In addition to the existing acquisition/control system of the test rig used to measure the 3D hill-chart of a turbine by classical static point-by-point method, a second digitizer has been added to acquire synchronized dynamic signals of the employed sensors. The optimal acceleration/deceleration ramps of the electrical drives have been previously identified in order to cope with the purpose of a reduced measurement time while avoiding errors and hysteresis on the acquired hydraulic characteristics. Finally, the comparison between the turbine efficiency hill-charts obtained by dynamic and static point-by-point methods shows a very good agreement in terms of precision and repeatability. Moreover, the applied dynamic method reduces significantly (by a factor of up to ten) the time necessary to measure the efficiency characteristics on model testing.

  15. Hydrodynamic evaluation of a hydraulic clarifier through hydraulic behaviour indicators and simplified flow models

    Directory of Open Access Journals (Sweden)

    Paola Patiño

    2012-04-01

    Full Text Available Hydrodynamic phenomena take place within water treatment plants associated with physical, operational and environmental factors which can affect the water quality. This study evaluated a hydraulic clarifier’s hydrodynamic pattern using sludge recirculation through continuous tracer test leading to determining hydraulic behaviour indicators and simplified flow models. The clarifier had dual flow with a predominantly complete mixture during the hours in which higher temperatures were reported for affluent water compared to those reported inside the reactor, causing the formation of density currents promoting mixing in the reactor and increased turbidity in the effluent. The hydraulic indicators and the Wolf-Resnick model had higher sensitivity to the influence of temperature on reactor hydrodynamics.

  16. Application research on hydraulic coke cutting monitoring system based on optical fiber sensing technology

    Science.gov (United States)

    Zhong, Dong; Tong, Xinglin

    2014-06-01

    With the development of the optical fiber sensing technology, the acoustic emission sensor has become one of the focal research topics. On the basis of studying the traditional hydraulic coke cutting monitoring system, the optical fiber acoustic emission sensor has been applied in the hydraulic coke cutting monitoring system for the first time, researching the monitoring signal of the optical fiber acoustic emission sensor in the system. The actual test results show that using the acoustic emission sensor in the hydraulic coke cutting monitoring system can get the real-time and accurate hydraulic coke cutting state and the effective realization of hydraulic coke cutting automatic monitoring in the Wuhan Branch of Sinopec.

  17. Problems associated with the use of rapid yielding hydraulic props.

    CSIR Research Space (South Africa)

    Glisson, FJ

    1998-08-01

    Full Text Available required to constantly move consumable support elements from surface to the stope face. This latter operation does not cease with the introduction of RYHP’s as pack timber or elongates are still transported. The effect is as such seldom quantified. Each... ton hydraulic props.10 Figure 1.2 Flow chart of the life of a hydraulic prop; from assembly to usage and repair when damaged. . . . . . . . . . . . . . . . . . 11 Figure 3.1 Performance of 10 hydraulic props that were batch tested prior...

  18. X65级高频焊接钢管爆裂原因分析%Cause Analysis on Bursting of X65 High Frequency Welded Steel Pipe

    Institute of Scientific and Technical Information of China (English)

    张良; 罗金恒; 冯耀荣; 张华; 张广利

    2011-01-01

    Bursting reasons for the φ457 mm× 7.1 mm X65 grade high frequency welded (HFW) pipeline was analyzed by means of chemical compositions analysis, mechanical properties test, metallographic examination and scanning electron microscope analysis.The results show that existing cold welding defects in the welding line and disqualification of impact ductility of the welding line were main reasons for the bursting.The effective bearing area reduced because of the cold welding defects and the original cracks initiated and expanded in the welding line.At the same time the ability of resistance the crack spreading was worsened because of low impact ductility of the welding line.So the X65 grade pipeline burst at the welding line under the force of hydraulic pressure test.%通过化学成分分析、力学性能测试、金相检验以及扫描电镜分析等方法对某规格为φ457 mm×7.1 mm的X65级高频焊(HFW)钢管水压试验时发生爆裂的原因进行了分析.结果表明:钢管爆裂失效是由于其直焊缝上存在冷焊缺陷以及焊缝冲击韧度不合格所致;焊缝中存在冷焊缺陷使其有效承载面积减小,原始裂纹在冷焊缺陷处萌生并扩展,加之焊缝冲击韧度低,抗裂纹扩展能力差,在水压试验压力作用下最终导致该钢管于焊缝处失稳爆裂.

  19. Hydraulic conductivity and diffusion characterization of GCLs

    Energy Technology Data Exchange (ETDEWEB)

    Mukunoki, T.; Rowe, R.K.; Li, H.M.; Sangam, H.P.; Hurst, P.; Bathurst, R.J. [Queen' s Univ., Kingston, ON (Canada)]|[Royal Military Coll. of Canada, Kingston, ON (Canada); Badv, K. [Urmia Univ. (Iran, Islamic Republic of)

    2003-07-01

    This paper reports on the characterization of the hydraulic conductivity and diffusion of a geosynthetic clay liner (GCL) installed at a site off the southeast coast of Baffin Island, in the Canadian Arctic, following different levels of freeze-thaw exposure and under low temperature conditions. The authors presented a summary of the results obtained for hydraulic conductivity tests on GCLs subjected to freeze-thaw cycles, and specimens permeated with jet fuel (Arctic diesel). They also reported on diffusion tests conducted at 22 Celsius and 5 Celsius, followed by a discussion of the effect of temperature. The results indicate that there is no significant impact on GCL performance due to freeze-thaw cycles, permeation by jet fuel or diffusion at the lower temperatures expected in the north for the short term (up to approximately four years). Additional studies are needed to confirm long term behaviour. 24 refs., 2 tabs., 4 figs.

  20. Hydraulic rams; a comparative investigation

    NARCIS (Netherlands)

    Tacke, J.H.P.M.

    1988-01-01

    A mathematical model describing the essential features of hydraulic ram operation is developed in order to clarify the possibilities and limitations of the ram relative to its site and its adjustments. The model distinguishes three different periods in the pumping cycle of the hydraulic ram: acceler

  1. Hydraulics. FOS: Fundamentals of Service.

    Science.gov (United States)

    John Deere Co., Moline, IL.

    This manual on hydraulics is one of a series of power mechanics texts and visual aids for training in the servicing of agricultural and industrial machinery. Focus is on oil hydraulics. Materials provide basic information and illustrations for use by vocational students and teachers as well as shop servicemen and laymen. The twelve chapters focus…

  2. Scientific design of a large-scale sodium thermal–hydraulic test facility for KALIMER—Part I: Scientific facility design

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Soon-Joon; Lee, Doo-Yong [FNC Tech. Co. Ltd., SNU 135-308, Kwanak-Ro 1, Kwanak-Gu, Seoul 151-742 (Korea, Republic of); Eoh, Jae-Hyuk, E-mail: jheoh@kaeri.re.kr [Korea Atomic Energy Research Institute, Fast Reactor Technology Development Division, 1045 Daedeok-daero, Yuseong, Daejeon 305-353 (Korea, Republic of); Lee, Tae-Ho; Lee, Yong-Bum [Korea Atomic Energy Research Institute, Fast Reactor Technology Development Division, 1045 Daedeok-daero, Yuseong, Daejeon 305-353 (Korea, Republic of)

    2013-12-15

    Highlights: • A 1/5 scale integral test facility design for a pool type sodium fast reactor. • Similarity assessment in heat transfer between the solid and fluid. • Reasonable scale-down of the prototype sodium fast reactor. • A 1-dimensional verification calculation with the scale-down model. • Scale-down approach showed good agreement of overall behaviors. - Abstract: A large scale test facility design simulating a pool type sodium fast reactor was carried out on the basis of rigorous scaling approach with a plan of its installation by 2016. In particular, a similarity in heat transfer between solid and fluid were intensively discussed together with the distortion, and viable design parameters were derived. A 1-dimensional verification calculation was also conducted and showed good agreement for the important parameters. This scaling approach in this study is expected to be used in the exact reproduction of heat transfer between fluid and solid in a single phase fluid system.

  3. A low order adaptive control scheme for hydraulic servo systems

    DEFF Research Database (Denmark)

    Andersen, Torben Ole; Pedersen, Henrik Clemmensen; Bech, Michael Møller;

    2015-01-01

    This paper deals with high-performance position control of hydraulics servo systems in general. The hydraulic servo system used is a two link robotic manipulator actuated by two hydraulic servo cylinders. A non-linear model of the hydraulic system and a Newton-Euler based model of the mechanical...... system were constructed and linearized. Controllers are implemented and tested on the manipulator. Pressure feedback was found to greatly improve system stability margins. Passive gain feedforward shows improved tracking performance for small changes in load pressure. For large changes in load pressure......, active gain feedforward shows a slightly improved performance. Computed-Torque Control shows better performance, but requires a well described system for best performance. A novel Adaptive Inverse Dynamics Controller was tested and the performance was found to be similar to that of Computed...

  4. A HORIZONTAL 2-D HYDRAULIC NUMERICAL MODEL AND IT'S APPLICATIONS TO FLOOD FORECAST

    Institute of Scientific and Technical Information of China (English)

    Minghui YU; Guolu YANG; Jinjun XU

    2002-01-01

    In this paper,a horizontal 2-D numerical model has been developed to simulate flow processes in dike burst. The finite difference method is used in computation. The model employs 2-D flow equations and can simulate complex flows when supercritical flow and sub-critical flow exist simultaneously such as hydraulic jumps. Several simulated results are worked out to demonstrate the applicability of the numerical model,such as flood propagation on a dry bed of a complex terrain.

  5. Assessing the reliability of eBURST using simulated populations with known ancestry

    Directory of Open Access Journals (Sweden)

    Connor Thomas R

    2007-04-01

    Full Text Available Abstract Background The program eBURST uses multilocus sequence typing data to divide bacterial populations into groups of closely related strains (clonal complexes, predicts the founding genotype of each group, and displays the patterns of recent evolutionary descent of all other strains in the group from the founder. The reliability of eBURST was evaluated using populations simulated with different levels of recombination in which the ancestry of all strains was known. Results For strictly clonal simulations, where all allelic change is due to point mutation, the groups of related strains identified by eBURST were very similar to those expected from the true ancestry and most of the true ancestor-descendant relationships (90–98% were identified by eBURST. Populations simulated with low or moderate levels of recombination showed similarly high performance but the reliability of eBURST declined with increasing recombination to mutation ratio. Populations simulated under a high recombination to mutation ratio were dominated by a single large straggly eBURST group, which resulted from the incorrect linking of unrelated groups of strains into the same eBURST group. The reliability of the ancestor-descendant links in eBURST diagrams was related to the proportion of strains in the largest eBURST group, which provides a useful guide to when eBURST is likely to be unreliable. Conclusion Examination of eBURST groups within populations of a range of bacterial species showed that most were within the range in which eBURST is reliable, and only a small number (e.g. Burkholderia pseudomallei and Enterococcus faecium appeared to have such high rates of recombination that eBURST is likely to be unreliable. The study also demonstrates how three simple tests in eBURST v3 can be used to detect unreliable eBURST performance and recognise populations in which there appears to be a high rate of recombination relative to mutation.

  6. Hydraulic Yaw System

    DEFF Research Database (Denmark)

    Stubkier, Søren; Pedersen, Henrik C.; Mørkholt, M.

    As wind turbines increase in size, combined with increased lifetime demands, new methods for load reduction needs to be examined. One method is to make the yaw system of the turbine soft/flexible and hereby dampen the loads to the system, which is the focus of the current paper. By utilizing...... the HAWC2 aeroelastic code and an extended model of the NREL 5MW turbine combined with a simplified linear model of the turbine, the parameters of the soft yaw system are optimized to reduce loading in critical components. Results shows that a significant reduction in fatigue and extreme loads to the yaw...... system and rotor shaft when utilizing the soft yaw drive concept compared to the original stiff yaw system. The physical demands of the hydraulic yaw system are furthermore examined for a life time of 20 years. Based on the extrapolated loads, the duty cycles show that it is possible to construct...

  7. Electro Hydraulic Hitch Control

    DEFF Research Database (Denmark)

    Hansen, M. R.; Andersen, T. O.; Nielsen, B.

    2003-01-01

    system for agricultural applications and driving for transportation. During tranport phases, the lack of suspension causes the vehicle to bounce and pitch, and makes it difficalt to control. Many systems have been proposed to cope with the oscillatory behavior, and different solutions exist. Common......This paper present and discusses R&D results on electro hydraulic hitch control for off-road vehicle, in particular active damping of oscillation occuring on tractors. The research deals with analysis and control of the oscillations occuring on tractors which are design without any susspection...... for most of the systems are that they operate on the hydrailc actuators generally providing the motive forces for moving the implement and/or attachment, typically a plough. The basic idea and physical working principle are to use the implement, moveable relative to the vehicle, as a damper mass. The paper...

  8. Performance of nano-hydraulic turbine utilizing waterfalls

    OpenAIRE

    Ikeda, Toshihiko; Iio, Shouichiro; Tatsuno, Kenji

    2010-01-01

    The aim of this investigation was to develop an environmentally friendly nano-hydraulic turbine utilizing waterfalls. A model of an impulse type hydraulic turbine constructed and tested with an indoor type waterfall to arrive at an optimum installation condition. Effects of an installation parameter, namely distance between the rotor and the waterfall on the power performance were studied. The flow field around the rotor was examined visually to clarify influences of installation conditions o...

  9. Gamma-ray bursts from massive Population-III stars: clues from the radio band

    Science.gov (United States)

    Burlon, D.; Murphy, T.; Ghirlanda, G.; Hancock, P. J.; Parry, R.; Salvaterra, R.

    2016-07-01

    Current models suggest gamma-ray bursts could be used as a way of probing Population-III stars - the first stars in the early Universe. In this paper, we use numerical simulations to demonstrate that late-time radio observations of gamma-ray burst afterglows could provide a means of identifying bursts that originate from Population-III stars, if these were highly massive, independently from their redshift. We then present the results from a pilot study using the Australia Telescope Compact Array at 17 GHz, designed to test the hypothesis that there may be Population-III gamma-ray bursts amongst the current sample of known events. We observed three candidates plus a control gamma-ray burst, and make no detections with upper limits of 20-40 μJy at 500-1300 d post-explosion.

  10. Gamma-ray bursts from massive Population III stars: clues from the radio band

    CERN Document Server

    Burlon, D; Ghirlanda, G; Hancock, P J; Parry, R; Salvaterra, R

    2016-01-01

    Current models suggest gamma-ray bursts could be used as a way of probing Population III stars - the first stars in the early Universe. In this paper we use numerical simulations to demonstrate that late time radio observations of gamma-ray burst afterglows could provide a means of identifying bursts that originate from Population III stars, if these were highly massive, independently from their redshift. We then present the results from a pilot study using the Australia Telescope Compact Array at 17 GHz, designed to test the hypothesis that there may be Population III gamma-ray bursts amongst the current sample of known events. We observed three candidates plus a control gamma-ray burst, and make no detections with upper limits of 20-40 uJy at 500-1300 days post explosion.

  11. Method of separation of celestial gamma-ray bursts from solar flares

    Science.gov (United States)

    Chuang, K. W.; White, R. S.; Klebesadel, R. W.; Laros, J. G.

    1992-01-01

    We recently discovered 217 'new' celestial gamma-ray burst candidates from the 'new' burst search of the PVO real time data base. The burst search covered the time period from September 1978 to July 1988. Sixty were confirmed by at least one other spacecraft, e.g., ISEE-3, V-II, V-12, etc. None triggered the PVO high time resolution memory. In this paper we describe a new algorithm based on the relationship between time width T(w) and hardness ratio HR, to distinguish cosmic gamma-ray bursts from solar flares without knowing the directions of the events. The algorithm was tested with 83 triggered and 60 nontriggered confirmed gamma-ray bursts and 30 confirmed solar flares from PVO.

  12. Pulsating hydraulic fracturing technology in low permeability coal seams

    Institute of Scientific and Technical Information of China (English)

    Wang Wenchao; Li Xianzhong; Lin Baiquan; Zhai Cheng

    2015-01-01

    Based on the difficult situation of gas drainage in a single coal bed of high gas content and low perme-ability, we investigate the technology of pulsating hydraulic pressure relief, the process of crank plunger movement and the mechanism of pulsating pressure formation using theoretical research, mathematical modeling and field testing. We analyze the effect of pulsating pressure on the formation and growth of fractures in coal by using the pulsating hydraulic theory in hydraulics. The research results show that the amplitude of fluctuating pressure tends to increase in the case where the exit is blocked, caused by pulsating pressure reflection and frictional resistance superposition, and it contributes to the growth of fractures in coal. The crack initiation pressure of pulsating hydraulic fracturing is 8 MPa, which is half than that of normal hydraulic fracturing;the pulsating hydraulic fracturing influence radius reaches 8 m. The total amount of gas extraction is increased by 3.6 times, and reaches 50 L/min at the highest point. The extraction flow increases greatly, and is 4 times larger than that of drilling without fracturing and 1.2 times larger than that of normal hydraulic fracturing. The technology provides a technical measure for gas drainage of high gas content and low permeability in the single coal bed.

  13. Analysis of well test data---Application of probabilistic models to infer hydraulic properties of fractures. [Contains list of standardized terminology or nomenclatue used in statistical models

    Energy Technology Data Exchange (ETDEWEB)

    Osnes, J.D. (RE/SPEC, Inc., Rapid City, SD (United States)); Winberg, A.; Andersson, J.E.; Larsson, N.A. (Sveriges Geologiska AB, Goeteborg (Sweden))

    1991-09-27

    Statistical and probabilistic methods for estimating the probability that a fracture is nonconductive (or equivalently, the conductive-fracture frequency) and the distribution of the transmissivities of conductive fractures from transmissivity measurements made in single-hole injection (well) tests were developed. These methods were applied to a database consisting of over 1,000 measurements made in nearly 25 km of borehole at five sites in Sweden. The depths of the measurements ranged from near the surface to over 600-m deep, and packer spacings of 20- and 25-m were used. A probabilistic model that describes the distribution of a series of transmissivity measurements was derived. When the parameters of this model were estimated using maximum likelihood estimators, the resulting estimated distributions generally fit the cumulative histograms of the transmissivity measurements very well. Further, estimates of the mean transmissivity of conductive fractures based on the maximum likelihood estimates of the model's parameters were reasonable, both in magnitude and in trend, with respect to depth. The estimates of the conductive fracture probability were generated in the range of 0.5--5.0 percent, with the higher values at shallow depths and with increasingly smaller values as depth increased. An estimation procedure based on the probabilistic model and the maximum likelihood estimators of its parameters was recommended. Some guidelines regarding the design of injection test programs were drawn from the recommended estimation procedure and the parameter estimates based on the Swedish data. 24 refs., 12 figs., 14 tabs.

  14. Testing of improved polyimide actuator rod seals at high temperature and under vacuum conditions for use in advanced aircraft hydraulic systems

    Science.gov (United States)

    Sellereite, B. K.; Waterman, A. W.; Nelson, W. G.

    1974-01-01

    Polyimide second-stage rod seals were evaluated to determine their suitability for applications in space station environments. The 6.35-cm (2.5-in.)K-section seal was verified for thermal cycling operation between room temperature and 478 K (400 F) and for operation in a 133 micron PA(0.000001 mm Hg) vacuum environment. The test seal completed the scheduled 96 thermal cycles and 1438 hr in vacuum with external rod seal leakage well within the maximum allowable of two drops per 25 actuation cycles. At program completion, the seals showed no signs of structural degradation. Posttest inspection showed the seals retained a snug fit against the shaft and housing walls, indicating additional wear life capability. Evaluation of a molecular flow section during vacuum testing, to inhibit fluid loss through vaporization, showed it to be beneficial with MIL-H-5606, a petroleum-base fluid, in comparison with MIL-H-83282, a synthetic hydrocarbon-base fluid.

  15. Detection of burst suppression patterns in EEG using recurrence rate.

    Science.gov (United States)

    Liang, Zhenhu; Wang, Yinghua; Ren, Yongshao; Li, Duan; Voss, Logan; Sleigh, Jamie; Li, Xiaoli

    2014-01-01

    Burst suppression is a unique electroencephalogram (EEG) pattern commonly seen in cases of severely reduced brain activity such as overdose of general anesthesia. It is important to detect burst suppression reliably during the administration of anesthetic or sedative agents, especially for cerebral-protective treatments in various neurosurgical diseases. This study investigates recurrent plot (RP) analysis for the detection of the burst suppression pattern (BSP) in EEG. The RP analysis is applied to EEG data containing BSPs collected from 14 patients. Firstly we obtain the best selection of parameters for RP analysis. Then, the recurrence rate (RR), determinism (DET), and entropy (ENTR) are calculated. Then RR was selected as the best BSP index one-way analysis of variance (ANOVA) and multiple comparison tests. Finally, the performance of RR analysis is compared with spectral analysis, bispectral analysis, approximate entropy, and the nonlinear energy operator (NLEO). ANOVA and multiple comparison tests showed that the RR could detect BSP and that it was superior to other measures with the highest sensitivity of suppression detection (96.49%, P = 0.03). Tracking BSP patterns is essential for clinical monitoring in critically ill and anesthetized patients. The purposed RR may provide an effective burst suppression detector for developing new patient monitoring systems.