WorldWideScience

Sample records for hybrid photovoltaic-wind power

  1. Photovoltaic-wind hybrid systems for remote power supply. Workshop. [Selected Papers

    Energy Technology Data Exchange (ETDEWEB)

    Huacuz, J. M.; Urrutia, M. [eds.] [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    This document include the papers of the RIER Workshop that was hold in Cancun, Mexico, on 21-25 April 1997. This Workshop was organized by the Non-Conventional Energy Unit of the Electrical Research Institute of Mexico (IIE), with the financial contributions from the Mexican National Council for Science and Technology (CONACYT) and the Iberoamerican Network for Rural Electrification with Renewable Energy (RIER) of the Program Science and Technology for Development (CYTED). The purpose of this Workshop was to present works developed on the technology of Photovoltaic-Wind Hybrid Systems, and to discuss both technical and non-technical factors that could foster or inhibit the widespread application this technology [Espanol] Este documento incluye los articulos tecnicos del taller de trabajo RIER, realizado en Cancun, Mexico, del 21 al 25 de abril de 1997. Este taller de trabajo fue organizado por el Instituto de Investigaciones Electricas (IIE), con la contribucion financiera del Consejo Nacional de Ciencia y Tecnologia (CONACYT) y de la Red de Trabajo Iberoamericana para la Electrificacion Rural con Energia Renovable (RIER) del programa Ciencia y Tecnologia para el Desarrollo (CYTED). El proposito de este taller fue presentar trabajos desarrollados sobre la tecnologia de sistemas hibridos fotovoltaicos y de viento, y discutir los factores tecnicos y no tecnicos que pudieran fomentar o detener la amplia aplicacion de esta tecnologia

  2. Technical Study of a Standalone Photovoltaic-Wind Energy Based Hybrid Power Supply Systems for Island Electrification in Malaysia.

    Directory of Open Access Journals (Sweden)

    Nahidul Hoque Samrat

    Full Text Available Energy is one of the most important factors in the socioeconomic development of a country. In a developing country like Malaysia, the development of islands is mostly related to the availability of electric power. Power generated by renewable energy sources has recently become one of the most promising solutions for the electrification of islands and remote rural areas. But high dependency on weather conditions and the unpredictable nature of these renewable energy sources are the main drawbacks. To overcome this weakness, different green energy sources and power electronic converters need to be integrated with each other. This study presents a battery storage hybrid standalone photovoltaic-wind energy power supply system. In the proposed standalone hybrid system, a DC-DC buck-boost bidirectional converter controller is used to accumulates the surplus hybrid power in the battery bank and supplies this power to the load during the hybrid power shortage by maintaining the constant dc-link voltage. A three-phase voltage source inverter complex vector control scheme is used to control the load side voltage in terms of the voltage amplitude and frequency. Based on the simulation results obtained from MATLAB/Simulink, it has been found that the overall hybrid framework is capable of working under variable weather and load conditions.

  3. Technical Study of a Standalone Photovoltaic-Wind Energy Based Hybrid Power Supply Systems for Island Electrification in Malaysia.

    Science.gov (United States)

    Samrat, Nahidul Hoque; Ahmad, Norhafizan; Choudhury, Imtiaz Ahmed; Taha, Zahari

    2015-01-01

    Energy is one of the most important factors in the socioeconomic development of a country. In a developing country like Malaysia, the development of islands is mostly related to the availability of electric power. Power generated by renewable energy sources has recently become one of the most promising solutions for the electrification of islands and remote rural areas. But high dependency on weather conditions and the unpredictable nature of these renewable energy sources are the main drawbacks. To overcome this weakness, different green energy sources and power electronic converters need to be integrated with each other. This study presents a battery storage hybrid standalone photovoltaic-wind energy power supply system. In the proposed standalone hybrid system, a DC-DC buck-boost bidirectional converter controller is used to accumulates the surplus hybrid power in the battery bank and supplies this power to the load during the hybrid power shortage by maintaining the constant dc-link voltage. A three-phase voltage source inverter complex vector control scheme is used to control the load side voltage in terms of the voltage amplitude and frequency. Based on the simulation results obtained from MATLAB/Simulink, it has been found that the overall hybrid framework is capable of working under variable weather and load conditions.

  4. A Technical, Economic, and Environmental Performance of Grid-Connected Hybrid (Photovoltaic-Wind Power System in Algeria

    Directory of Open Access Journals (Sweden)

    Djohra Saheb-Koussa

    2013-01-01

    Full Text Available This paper studies the technical, economic, and environmental analysis of wind and photovoltaic power systems connected to a conventional grid. The main interest in such systems is on-site consumption of the produced energy, system hybridization, pooling of resources, and contribution to the environment protection. To ensure a better management of system energy, models have been used for determining the power that the constituting subsystems can deliver under specific weather conditions. Simulation is performed using MATLAB-SIMULINK. While, the economic and environmental study is performed using HOMER software. From an economic point of view, this allows to compare the financial constraints on each part of the system for the case of Adrar site which is located to the northern part of the south of Algeria. It also permits to optimally size and select the system presenting the best features on the basis of two parameters, that is, cost and effectiveness. From an environmental point of view, this study allows highlighting the role of renewable energy in reducing gas emissions related to greenhouse effects. In addition, through a set of sensitivity analysis, it is found that the wind speed has more effects on the environmental and economic performances of grid-connected hybrid (photovoltaic-wind power systems.

  5. A technical, economic, and environmental performance of grid-connected hybrid (photovoltaic-wind) power system in Algeria.

    Science.gov (United States)

    Saheb-Koussa, Djohra; Koussa, Mustapha; Said, Nourredine

    2013-01-01

    This paper studies the technical, economic, and environmental analysis of wind and photovoltaic power systems connected to a conventional grid. The main interest in such systems is on-site consumption of the produced energy, system hybridization, pooling of resources, and contribution to the environment protection. To ensure a better management of system energy, models have been used for determining the power that the constituting subsystems can deliver under specific weather conditions. Simulation is performed using MATLAB-SIMULINK. While, the economic and environmental study is performed using HOMER software. From an economic point of view, this allows to compare the financial constraints on each part of the system for the case of Adrar site which is located to the northern part of the south of Algeria. It also permits to optimally size and select the system presenting the best features on the basis of two parameters, that is, cost and effectiveness. From an environmental point of view, this study allows highlighting the role of renewable energy in reducing gas emissions related to greenhouse effects. In addition, through a set of sensitivity analysis, it is found that the wind speed has more effects on the environmental and economic performances of grid-connected hybrid (photovoltaic-wind) power systems.

  6. A Technical, Economic, and Environmental Performance of Grid-Connected Hybrid (Photovoltaic-Wind) Power System in Algeria

    Science.gov (United States)

    Saheb-Koussa, Djohra; Koussa, Mustapha; Said, Nourredine

    2013-01-01

    This paper studies the technical, economic, and environmental analysis of wind and photovoltaic power systems connected to a conventional grid. The main interest in such systems is on-site consumption of the produced energy, system hybridization, pooling of resources, and contribution to the environment protection. To ensure a better management of system energy, models have been used for determining the power that the constituting subsystems can deliver under specific weather conditions. Simulation is performed using MATLAB-SIMULINK. While, the economic and environmental study is performed using HOMER software. From an economic point of view, this allows to compare the financial constraints on each part of the system for the case of Adrar site which is located to the northern part of the south of Algeria. It also permits to optimally size and select the system presenting the best features on the basis of two parameters, that is, cost and effectiveness. From an environmental point of view, this study allows highlighting the role of renewable energy in reducing gas emissions related to greenhouse effects. In addition, through a set of sensitivity analysis, it is found that the wind speed has more effects on the environmental and economic performances of grid-connected hybrid (photovoltaic-wind) power systems. PMID:24489488

  7. Modeling and sizing optimization of hybrid photovoltaic/wind power generation system

    Science.gov (United States)

    Yazdanpanah, Mohammad-Ali

    2014-03-01

    The rapid industrialization and growth of world's human population have resulted in the unprecedented increase in the demand for energy and in particular electricity. Depletion of fossil fuels and impacts of global warming caused widespread attention using renewable energy sources, especially wind and solar energies. Energy security under varying weather conditions and the corresponding system cost are the two major issues in designing hybrid power generation systems. In this paper, the match evaluation method (MEM) is developed based on renewable energy supply/demand match evaluation criteria to size the proposed system in lowest cost. This work is undertaken with triple objective function: inequality coefficient, correlation coefficient, and annualized cost of system. It provides optimum capacity of as many numbers of supplies as required to match with a load demand in lowest investment, so it can handle large-scale design problems. Meteorological data were collected from the city of Zabol, located in south-east of Iran, as a case study. Six types of wind turbine and also six types of PV modules, with different output powers and costs, are considered for this optimization procedure. A battery storage system is used to even out irregularities in meteorological data. A multi-objective particle swarm optimization algorithm has been used for the prediction of an optimized set of design based on the MEM technique. The results of this study are valuable for evaluating the performance of future stand-alone hybrid power system. It is worth mentioning that the proposed methodology can be effectively employed for any composition of hybrid energy systems in any locations taking into account the meteorological data and the consumer's demand.

  8. Study on Maximum Power Point Tracking and Inverter Control of Hybrid Photovoltaic-Wind Power Generation System%风光互补发电系统MPPT及其逆变电源控制的研究

    Institute of Scientific and Technical Information of China (English)

    葛超铭; 李少纲

    2013-01-01

      为了实现风光互补发电系统的最大功率点跟踪(MPPT),根据风能与太阳能的特性,采用双输入DC/DC变换器作为前级电路,在扰动法的基础上提出自调整MPPT控制策略,有效改善了系统的跟踪速度,避免误操作,减小工作点的震荡,并提高了系统效率。针对逆变电源控制,把自动调节反馈系数的PID控制系统与重复控制系统相结合,不仅提出复合控制算法,使系统具有较好的动静态特性,且改善了逆变器输出波形的质量。%In order to realize maximum power point tracking (MPPT) of hybrid photovoltaic-wind power generation system, dual input DC/DC converter was adopted as the forward circuit according to features of wind energy and solar energy. On the basis of disturbance method, the self-adjusting MPPT control strategy was raised to have effectively improved tracking speed of the system, avoiding misopera-tion, reducing vibration of working point and raising the system efficiency. As for inverter control, the PID control system for auto-adjusting feeding coefficient was combined with the repetitive control system. This paper not only raised the repetitive control algorithm, making the system have better static and dynamic characteristics, but also improved quality of inverter output waveforms.

  9. MODELING, SIMULATON AND SIZING OF PHOTOVOLTAIC/WIND/FUEL CELL HYBRID GENERATION SYSTEM

    Directory of Open Access Journals (Sweden)

    Dr.S.LATHA

    2012-05-01

    Full Text Available The depleting fossil fuel reserves and increasing concern towards global warming have created the need to surge for the alternative power generation options. Renewable energy sources like Wind, Solar-PV, Biomass and fuel cells are gaining prominence nowadays, as they are more energy efficient, reduce pollution and also they serveas a promising solution to the toughest energy crisis faced during the recent years. This paper focuses on the modeling and simulation of solar – photovoltaic, wind and fuel cell hybrid energy systems using MATLAB/Simulink software. The intermittent nature of solar and wind energy sources make them unreliable. Hence Maximum Power Point Tracking (MPPT is used to extract maximum power from the wind and sunwhen it is available. The standard perturb and observe method of MPPT is used for the PV system and for the wind generation system. The simulation results of the PV/Wind /Fuel cell hybrid system are presented in graph showing the effectiveness of the proposed system model. Also, hardware implementation of microcontroller based MPPT for solar-PV alone and unit sizing of the hybrid system for the PG simulation lab in EEE Dept. of Thiagarajar College of Engineering is depicted in the paper.

  10. A Hybrid Spline Metamodel for Photovoltaic/Wind/Battery Energy Systems

    OpenAIRE

    ZAIBI, Malek; LAYADI, Toufik Madani; Champenois, Gérard; ROBOAM, xavier; Sareni, Bruno; Belhadj, Jamel

    2015-01-01

    This paper proposes a metamodel design for a Photovoltaic/Wind/Battery Energy System. The modeling of a hybrid PV/wind generator coupled with two kinds of storage i.e. electric (battery) and hydraulic (tanks) devices is investigated. A metamodel is carried out by hybrid spline interpolation to solve the relationships between several design variables i.e. the design parameters of different subsystems and their associate response variables i.e. system indicators performance. The developed model...

  11. Photovoltaic-wind hybrid autonomous generation systems in Mongolia

    Energy Technology Data Exchange (ETDEWEB)

    Dei, Tsutomu; Ushiyama, Izumi

    2005-01-01

    Two hybrid stand-alone (autonomous) power systems, each with wind and PV generation, were studied as installed at health clinics in semi-desert and mountainous region in Mongolia. Meteorological and system operation parameters, including power output and the consumption of the system, were generally monitored by sophisticated monitoring. However, where wind and solar site information was lacking, justifiable estimates were made. The results show that there is a seasonal complementary relationship between wind and solar irradiation in Tarot Sum. The users understood the necessity of Demand Side Management of isolated wind-PV generation system through technology transfer seminars and actually executed DSM at both sites. (author)

  12. Photovoltaic-wind hybrid system for permanent magnet DC motor

    Science.gov (United States)

    Nasir, M. N. M.; Lada, M. Y.; Baharom, M. F.; Jaafar, H. I.; Ramani, A. N.; Sulaima, M. F.

    2015-05-01

    Hybrid system of Photovoltaic (PV) - Wind turbine (WT) generation has more advantages and reliable compared to PV or wind turbine system alone. The aim of this paper is to model and design hybrid system of PV-WT supplying 100W permanent-magnet dc motor. To achieve the objective, both of PV and WT are connected to converter in order to get the same source of DC supply. Then both sources were combined and straightly connected to 100W permanent magnet dc motor. All the works in this paper is only applied in circuit simulator by using Matlab Simulink. The output produced from each converter is expected to be suit to the motor specification. The output produced from each renewable energy system is as expected to be high as it can support the motor if one of them is breakdown

  13. Development of emergency backup power system using photovoltaic/wind hybrid power source in unmanned relay broadcasting station; Mujin chukei hosojo ni okeru taihoko/furyoku hybrid dengen wo mochiita hijo yobi dengen system no kaihatsu. 1

    Energy Technology Data Exchange (ETDEWEB)

    Nishikawa, S.; Takanaga, T. [Kandenko Co. Ltd., Tokyo (Japan); Sugimoto, T.; Fujiwara, S. [Japan Broadcasting Corp., Tokyo (Japan)

    1996-02-01

    An examination was made on the application of photovoltaic and wind power generation as an emergency backup power source. In this connection, the designing/manufacturing was carried out for a field demonstration test system, and also a simulation was carried out concerning the system performance. In the structure of the hybrid power source, a wind power generator is parallelly connected to a solar cell through a DC/DC converter for adjusting output voltage. It is further parallelly connected to an existing power system through a switch, supplying power to storage batteries or a broadcasting equipment. The result of the simulation revealed that, in the static characteristics, there was an output from the wind power generation if the wind velocity was 2.4m/s or above, but that a discharge from storage batteries was necessary even in the maximum performance of the wind power generation if the intensity of solar radiation was less than approximately 0.5kW/m{sup 2}. In the dynamic characteristics, an evaluation was made on the length of time of the on-load power supply after a power failure of the system in comparison with the conventional length, depending on the conditions of the wind. 2 refs., 7 figs., 1 tab.

  14. Dimensioning of a photovoltaic-wind hybrid system in UFRJ campus of the Ilha do Fundao; Dimensionamento de um sistema hibrido eolico-fotovoltaico na UFRJ Campus Ilha do Fundao

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Silvio Carlos Anibal de [Universidade Federal do Rio de Janeiro (DEM/UFRJ), RJ (Brazil). Dept. de Engenharia Mecanica], e-mail: silvioa@gmail.com; Santos, Rodrigo Zimmer de Abreu; Argolo, Felipe Henrique Bohm; Danziger, Fernando Artur Ragoni; Sollero, Luiz Paulo Vervloet; Castro, Marcial Pereira Saboya de [Universidade Federal do Rio de Janeiro (DEM/UFRJ), RJ (Brazil). Dept. de Engenharia Industrial], e-mail: rodzimmer@gmail.com, e-mail: felipeargolo@yahoo.com.br, e-mail: ragonziger@gmail.com, e-mail: lpsollero@gmail.com, e-mail: marcial.saboya@gmail.com

    2008-07-01

    A techno-economic analysis of a grid connected photovoltaic-wind hybrid energy system is done in the present paper. The set-up consists of photovoltaic solar-cell arrays, wind generators, a lead acid storage batteries and an inverter unit to convert DC power to AC power. The study has been performed with the simulation tool HOMER (Hybrid Optimization Model for Electric Renewable) developed by the National Renewable Energy Laboratory (NREL) for techno-economical feasibility studies of hybrid systems. The system is connected to the electrical grid in order to supply all the electrical energy demand of the Technological Centre of the Federal University of Rio de Janeiro. Many systems configurations have been considered and it was possible to simulate the hourly operation of each system and to calculate technical, economic and environmental performance parameters. The best configuration is a Fuhrlander 30 wind generator, associated to a photovoltaic system to reach the generation of 96% of the energy demand by means of renewable sources. (author)

  15. A hybrid solar photovoltaic-wind turbine-Rankine cycle for electricity generation in Turkish Republic of Northern Cyprus

    Directory of Open Access Journals (Sweden)

    Samuel Asumadu-Sarkodie

    2016-12-01

    Full Text Available This paper presents an energy demand model by designing a hybrid solar-wind-thermal power generation system of the Turkish Republic of Northern Cyprus, a promising substitute for the expensive battery banks. The study models the future energy demand of Turkish Republic of Northern Cyprus based on the IPCC emissions scenario A1B and A2 by designing a new hybrid solar-wind-thermal power system that satisfies the current and future requirements of firm capacity during peak periods. The study suggests an improvement in a hybrid solar-wind-thermal power system performance by predicting reliable outputs that can integrate renewable energy technologies to conventional power generation. The energy consumption prediction model emphasizes the energy requirement that has a growing demand from 300 to 400 GWh in scenario A1B and 150–450 GWh in scenario A2 from 2010 to 2050. The proposed design can meet 400 GWh of electricity demand in TRNC based on IPCC scenario A1B and 450 GWh of electricity demand in TRNC based on IPCC scenario A2. The percentage contribution of solar, wind and thermal energy for 2010, 2020, 2030, 2040 and 2050 are presented along with CO2 emissions and water consumption for each of the years.

  16. Sizing and Simulation of PV-Wind Hybrid Power System

    OpenAIRE

    Mustafa Engin

    2013-01-01

    A sizing procedure is developed for hybrid system with the aid of mathematical models for photovoltaic cell, wind turbine, and battery that are readily present in the literature. This sizing procedure can simulate the annual performance of different kinds of photovoltaic-wind hybrid power system structures for an identified set of renewable resources, which fulfills technical limitations with the lowest energy cost. The output of the program will display the performance of the system during t...

  17. Power quality analysis of hybrid renewable energy system

    Directory of Open Access Journals (Sweden)

    Rinchin W. Mosobi

    2015-12-01

    Full Text Available An hybrid renewable energy sources consisting of solar photovoltaic, wind energy system, and a microhydro system is proposed in this paper. This system is suitable for supplying electricity to isolated locations or remote villages far from the grid supply. The solar photovoltaic system is modeled with two power converters, the first one being a DC-DC converter along with an maximum power point tracking to achieve a regulated DC output voltage and the second one being a DC-AC converter to obtain AC output. The wind energy system is modeled with a wind-turbine prime mover with varying wind speed and fixed pitch angle to drive an self excited induction generator (SEIG. Owing to inherent drooping characteristics of the SEIG, a closed loop turbine input system is incorporated. The microhydro system is modeled with a constant input power to drive an SEIG. The three different sources are integrated through an AC bus and the proposed hybrid system is supplied to R, R-L, and induction motor loads. A static compensator is proposed to improve the load voltage and current profiles; it also mitigates the harmonic contents of the voltage and current. The static synchronous compensator is realized by means of a three-phase IGBT-based current-controlled voltage source inverter with a self-supporting DC bus. The complete system is modeled and simulated using Matlab/Simulink. The simulation results obtained illustrate the feasibility of the proposed system and are found to be satisfactory.

  18. Sizing and Simulation of PV-Wind Hybrid Power System

    Directory of Open Access Journals (Sweden)

    Mustafa Engin

    2013-01-01

    Full Text Available A sizing procedure is developed for hybrid system with the aid of mathematical models for photovoltaic cell, wind turbine, and battery that are readily present in the literature. This sizing procedure can simulate the annual performance of different kinds of photovoltaic-wind hybrid power system structures for an identified set of renewable resources, which fulfills technical limitations with the lowest energy cost. The output of the program will display the performance of the system during the year, the total cost of the system, and the best size for the PV-generator, wind generator, and battery capacity. Security lightning application is selected, whereas system performance data and environmental operating conditions are measured and stored. This hybrid system, which includes a PV, wind turbine, inverter, and a battery, was installed to supply energy to 24 W lamps, considering that the renewable energy resources of this site where the system was installed were 1700 Wh/m2/day solar radiation and 3.43 m/s yearly average wind speed. Using the measured variables, the inverter and charge regulator efficiencies were calculated as 90% and 98%, respectively, and the overall system’s electrical efficiency is calculated as 72%. Life cycle costs per kWh are found to be $0.89 and LLP = 0.0428.

  19. Structure and functioning of a aerated water treatment system powered by photovoltaic/wind energy in Slender West Lake%瘦西湖风光电能驱动的曝气生物接触氧化水净化系统结构与功能

    Institute of Scientific and Technical Information of China (English)

    胡孟春; 张永春; 王文林; 唐晓燕

    2012-01-01

    在瘦西湖选择中试河段,利用太阳能风能绿色能源,研发了风光电能驱动的曝气生物接触氧化水净化系统。系统由风光互补发电子系统、曝气生物接触氧化子系统、植物生态子系统组成。风光电能驱动的曝气生物接触氧化水净化系统运行正常。按照景观娱乐用水水质标准进行水质监测,采用模糊综合评价与贴近度计算方法,进行了系统水净化功能评价。结果表明,在试验段原水水质低于景观水C类,经该系统水净化后,可以达到景观水B类。系统的开发与实验,探索了利用绿色能源河湖水净化的新途径。%A pilot photovoltaic/wind driven water treatment system was set up near Slender West Lake in southeastern China.The system has three central components,the photovoltaic/wind hybrid generation system,the biological oxidation treatment system and plant biological subsystem.The hybrid(photovoltaic/wind) system provides energy for the aeration treatment system in a good condition.During the pilot tests,the water quality was monitored and compared to the water quality standards.The water treatment efficiency was evaluated using Fuzzy integrative assessment and a proximity computation method.The data showed that water quality in the test river section was below Class C.After treatment,the water quality reached Class B,meeting the standard for scenic and recreation areas.The development and testing of the hybrid treatment system illustrates a new approach to treating poor quality waters using green energy.

  20. The Power of Hybridization

    CERN Document Server

    CERN. Geneva

    2011-01-01

    Programming languages always seem to do some things well but not others: Python punts when it comes to user interfaces, Java’s artificial complexity prevents rapid development and produces tangles, and it will be awhile before we see benefits from C++ concurrency work. The cognitive load of languages and their blind spots increases the cost of experimentation, impeding your ability to fail fast and iterate. If you use a single language to solve your problem, you are binding yourself to the worldview limitations and the mistakes made by the creator of that language. Consider increasing your wiggle room by crossing language boundaries, complementing a language that is powerful in one area with a different language powerful in another. Language hybridization can speed development to quickly discover your real problems, giving you more time to fix them. After making a case for hybridizing your thinking in general, I will present a number of simple examples; first showing the benefits of using other languages...

  1. Hybrid Power Management (HPM)

    Science.gov (United States)

    Eichenberg, Dennis J.

    2007-01-01

    The NASA Glenn Research Center s Avionics, Power and Communications Branch of the Engineering and Systems Division initiated the Hybrid Power Management (HPM) Program for the GRC Technology Transfer and Partnership Office. HPM is the innovative integration of diverse, state-of-the-art power devices in an optimal configuration for space and terrestrial applications. The appropriate application and control of the various power devices significantly improves overall system performance and efficiency. The advanced power devices include ultracapacitors and fuel cells. HPM has extremely wide potential. Applications include power generation, transportation systems, biotechnology systems, and space power systems. HPM has the potential to significantly alleviate global energy concerns, improve the environment, and stimulate the economy. One of the unique power devices being utilized by HPM for energy storage is the ultracapacitor. An ultracapacitor is an electrochemical energy storage device, which has extremely high volumetric capacitance energy due to high surface area electrodes, and very small electrode separation. Ultracapacitors are a reliable, long life, maintenance free, energy storage system. This flexible operating system can be applied to all power systems to significantly improve system efficiency, reliability, and performance. There are many existing and conceptual applications of HPM.

  2. Hybrid power semiconductor

    Science.gov (United States)

    Chen, D. Y.

    1985-10-01

    The voltage rating of a bipolar transistor may be greatly extended while at the same time reducing its switching time by operating it in conjunction with FETs in a hybrid circuit. One FET is used to drive the bipolar transistor while the other FET is connected in series with the transistor and an inductive load. Both FETs are turned on or off by a single drive signal of load power, the second FET upon ceasing conductions, rendering one power electrode of the bipolar transistor open. Means are provided to dissipate currents which flow after the bipolar transistor is rendered nonconducting.

  3. Technical Study of a Standalone Photovoltaic–Wind Energy Based Hybrid Power Supply Systems for Island Electrification in Malaysia

    Science.gov (United States)

    Samrat, Nahidul Hoque; Ahmad, Norhafizan; Choudhury, Imtiaz Ahmed; Taha, Zahari

    2015-01-01

    Energy is one of the most important factors in the socioeconomic development of a country. In a developing country like Malaysia, the development of islands is mostly related to the availability of electric power. Power generated by renewable energy sources has recently become one of the most promising solutions for the electrification of islands and remote rural areas. But high dependency on weather conditions and the unpredictable nature of these renewable energy sources are the main drawbacks. To overcome this weakness, different green energy sources and power electronic converters need to be integrated with each other. This study presents a battery storage hybrid standalone photovoltaic-wind energy power supply system. In the proposed standalone hybrid system, a DC-DC buck-boost bidirectional converter controller is used to accumulates the surplus hybrid power in the battery bank and supplies this power to the load during the hybrid power shortage by maintaining the constant dc-link voltage. A three-phase voltage source inverter complex vector control scheme is used to control the load side voltage in terms of the voltage amplitude and frequency. Based on the simulation results obtained from MATLAB/Simulink, it has been found that the overall hybrid framework is capable of working under variable weather and load conditions. PMID:26121032

  4. Dynamic programming for reduction of fuel consumption in a photovoltaic/wind/diesel generating system; Doteki keikakuho ni yoru taiyoko/furyoku/diesel hatsuden system no nenryo shohiryo no sakugen

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, K.; Kenmoku, Y.; Sakakibara, T. [Toyohashi University of Technology, Aichi (Japan); Nakagawa, S. [Maizuru National College of Technology, Kyoto (Japan); Kawamoto, T. [Shizuoka University, Shizuoka (Japan)

    1997-11-25

    Dynamic programming is employed in the study of the operation of the diesel engine in a photovoltaic/wind-force/diesel-engine power generating system, which aims at reduction in the system fuel consumption and at determining an optimum system constitution. The parameters set in this system are the photovoltaic/wind-force supply rate, photovoltaic/wind-force power generation ratio, and battery capacity. An island in Ise Bay, with an annual load power of approximately 1.59-million kWh and mean daily load power of approximately 4336kWh is assumed as the location for the system. Observation data of Ommaezaki Weather Station are utilized for the calculation of the amount of photovoltaic/wind-force power generation. It is found as the result that the fuel consumption of the diesel engine in this system decreases to 82-84% when the natural energy supply rate is 20%. It is also found that the fuel consumption of the system records the minimum at a photovoltaic/wind-force ratio of 60/40, irrespective of the battery capacity or natural energy supply rate, and this ratio is the optimum ratio. 3 refs., 9 figs., 1 tab.

  5. Hybrid power source

    Science.gov (United States)

    Singh, Harmohan N.

    2012-06-05

    A hybrid power system is comprised of a high energy density element such as a fuel-cell and high power density elements such as a supercapacitor banks. A DC/DC converter electrically connected to the fuel cell and converting the energy level of the energy supplied by the fuel cell. A first switch is electrically connected to the DC/DC converter. First and second supercapacitors are electrically connected to the first switch and a second switch. A controller is connected to the first switch and the second switch, monitoring charge levels of the supercapacitors and controls the switching in response to the charge levels. A load is electrically connected to the second switch. The first switch connects the DC/DC converter to the first supercapacitor when the second switch connects the second supercapacitor to the load. The first switch connects the DC/DC converter to the second supercapacitor when the second switch connects the first supercapacitor to the load.

  6. Hybrid Power Management System and Method

    Science.gov (United States)

    Eichenberg, Dennis J. (Inventor)

    2008-01-01

    A system and method for hybrid power management. The system includes photovoltaic cells, ultracapacitors, and pulse generators. In one embodiment, the hybrid power management system is used to provide power for a highway safety flasher.

  7. Optimal Sizing of a Hybrid Grid-Connected Photovoltaic–Wind–Biomass Power System

    Directory of Open Access Journals (Sweden)

    Arnau González

    2015-09-01

    Full Text Available Hybrid renewable energy systems (HRES are a trendy alternative to enhance the renewable energy deployment worldwide. They effectively take advantage of scalability and flexibility of these energy sources, since combining two or more allows counteracting the weaknesses of a stochastic renewable energy source with the strengths of another or with the predictability of a non-renewable energy source. This work presents an optimization methodology for minimum life cycle cost of a HRES based on solar photovoltaic, wind and biomass power. Biomass power seeks to take advantage of locally available forest wood biomass in the form of wood chips to provide energy in periods when the PV and wind power generated are not enough to match the existing demand. The results show that a HRES combining the selected three sources of renewable energy could be installed in a rural township of about 1300 dwellings with an up-front investment of US $7.4 million, with a total life cycle cost of slightly more than US $30 million. Such a system would have benefits in terms of energy autonomy and environment quality improvement, as well as in term of job opportunity creation.

  8. Hybrid power plants; Thermische Hybridkraftwerke

    Energy Technology Data Exchange (ETDEWEB)

    Tuschy, I. [ALSTOM Power Support, Mannheim (Germany). Bereiche Forschung und Entwicklung/Ingenieurdienstleistungen; Franke, U. [Fachhochschule Flensburg (Germany). Thermodynamik

    2002-07-01

    New German laws concerning the use of biomass and other renewable energy sources have improved the conditions for power generation with renewable energies. A promising alternative to common small-scale (combined-heat-and-) power plants could be found in so-called hybrid power plants which use renewable energies and fossil fuels in combination. A thermodynamic process analysis shows how to determine the renewable energies' portion of a hybrid power plant's total output. [German] Mit den veraenderten gesetzlichen Rahmenbedingungen erhoeht sich die Motivation, regenerative Energiequellen zur Stromerzeugung zu nutzen. Neben dem exklusiven Einsatz in kleineren (Heiz-) Kraftwerken bietet sich die gemeinsame Nutzung mit fossilen Energietraegern in sogenannten Hybridkraftwerken an. Hier stellt sich die Frage, wie der Anteil der regenerativen Energien an der Gesamt-Stromproduktion des Hybridkraftwerkes zu ermitteln ist. Eine thermodynamische Prozessanalyse kann darueber Aufschluss geben.

  9. Hybrid Magnetics and Power Applications

    DEFF Research Database (Denmark)

    Mo, Wai Keung; Paasch, Kasper

    A hybrid magnetic approach, merging two different magnetic core properites such as ferrite and iron powder cores, is an effective solution for power converter applications. It can offer similar magnetic properties to that of magnetic powder cores but showing less copper loss than powder cores...

  10. Hybrid Magnetics and Power Applications

    DEFF Research Database (Denmark)

    Mo, Wai Keung; Paasch, Kasper

    2017-01-01

    . In order to prevent ferrite core saturation, placing an effective air gap within the ferrite core is a key method to obtain optimum hybrid magnetic performance. Furthermore, a relatively large inductance at low loading current is an excellent way to minimze power loss in order to achieve high efficiency...

  11. Technical analysis of photovoltaic/wind systems with hydrogen storage

    Directory of Open Access Journals (Sweden)

    Bakić Vukman V.

    2012-01-01

    Full Text Available The technical analysis of a hybrid wind-photovoltaic energy system with hydrogen gas storage was studied. The market for the distributed power generation based on renewable energy is increasing, particularly for the standalone mini-grid applications. The main design components of PV/Wind hybrid system are the PV panels, the wind turbine and an alkaline electrolyzer with tank. The technical analysis is based on the transient system simulation program TRNSYS 16. The study is realized using the meteorological data for a Typical Metrological Year (TMY for region of Novi Sad, Belgrade cities and Kopaonik national park in Serbia. The purpose of the study is to design a realistic energy system that maximizes the use of renewable energy and minimizes the use of fossil fuels. The reduction in the CO2 emissions is also analyzed in the paper. [Acknowledgment. This paper is the result of the investigations carried out within the scientific project TR33036 supported by the Ministry of Science of the Republic of Serbia.

  12. Performance of a small stand alone photovoltaic-wind system at El Oyameyo D.F., Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Juarez, A.; Campos, J. [Centro de Investigacion en Energia, UNAM, Mexico, D. F. (Mexico); Tiburcio Silver, A. [Instituto Tecnologico de Toluca-Division de Posgrado, Toluca (Mexico)

    1997-12-31

    El Oyameyo, is an ecological site located to the South-West of the Topilejo town, D.F., 19 degree 25` North latitude, 99 degree 5` West longitude and at an altitude of 3100 m. At present, there are 10 families living at this place. They have energy generators to produce their own electricity by means of solar or wind energy using photovoltaic (PV) technology and eolic systems, respectively. There are three different configurations of energy generators: DC regulated PV systems, AC regulated PV systems and one PV-Wind hybrid system. The electrical power installed for the stand alone PV systems are from 48 W-p up to 768 W-p range. Among these, there are 4 PV systems that are configurated in DC regulated systems, and other 6 are AC regulated systems. All these systems use lead-acid battery (scaled or vented) banks to store the energy produced daily by the systems. The PV-Wind hybrid system in formed, at present, by a 5.0 kW wind generator, a PV array of 768 W-p, a 37.8 kW-h storage battery bank and a 5.0 kW DC/AC inverter. In this work, we report the electricity generated, load pattern and overall system performance of the photovoltaic-wind hybrid system. The technical characteristics, energy test on the hybrid system and the experience obtained from energy handling and system maintenance for all the systems are presented. We found that all the systems had shown good performance and users` satisfaction. [Espanol] El Oyameyo es un lugar ecologico localizado al Sur-Oeste del pueblo de Topilejo, D. F., 19 grados 25` de latitud Norte 99 grados 5` de longitud Oeste y a una altitud de 3100m. Actualmente hay 10 familias viviendo en este lugar. Tienen generadores de energia para producir su propia electricidad mediante la energia solar y la del viento usando sistemas fotovoltaicos (FV) y sistemas eolicos, respectivamente. Hay tres diferentes configuraciones de generadores de energia: sistemas fotovoltaicos de CD regulados, sistemas fotovoltaicos de CA regulados y un sistema

  13. Hybrid2 - The hybrid power system simulation model

    Energy Technology Data Exchange (ETDEWEB)

    Baring-Gould, E.I.; Green, H.J.; Dijk, V.A.P. van [National Renewable Energy Lab., Golden, CO (United States); Manwell, J.F. [Univ. of Massachusetts, Amherst, MA (United States)

    1996-12-31

    There is a large-scale need and desire for energy in remote communities, especially in the developing world; however the lack of a user friendly, flexible performance prediction model for hybrid power systems incorporating renewables hindered the analysis of hybrids as options to conventional solutions. A user friendly model was needed with the versatility to simulate the many system locations, widely varying hardware configurations, and differing control options for potential hybrid power systems. To meet these ends, researchers from the National Renewable Energy Laboratory (NREL) and the University of Massachusetts (UMass) developed the Hybrid2 software. This paper provides an overview of the capabilities, features, and functionality of the Hybrid2 code, discusses its validation and future plans. Model availability and technical support provided to Hybrid2 users are also discussed. 12 refs., 3 figs., 4 tabs.

  14. Economics of hybrid photovoltaic power plants

    Energy Technology Data Exchange (ETDEWEB)

    Breyer, Christian

    2012-08-16

    The global power supply stability is faced to several severe and fundamental threats, in particular steadily increasing power demand, diminishing and degrading fossil and nuclear energy resources, very harmful greenhouse gas emissions, significant energy injustice and a structurally misbalanced ecological footprint. Photovoltaic (PV) power systems are analysed in various aspects focusing on economic and technical considerations of supplemental and substitutional power supply to the constraint conventional power system. To infer the most relevant system approach for PV power plants several solar resources available for PV systems are compared. By combining the different solar resources and respective economics, two major PV systems are identified to be very competitive in almost all regions in the world. The experience curve concept is used as a key technique for the development of scenario assumptions on economic projections for the decade of the 2010s. Main drivers for cost reductions in PV systems are learning and production growth rate, thus several relevant aspects are discussed such as research and development investments, technical PV market potential, different PV technologies and the energetic sustainability of PV. Three major market segments for PV systems are identified: off-grid PV solutions, decentralised small scale on-grid PV systems (several kWp) and large scale PV power plants (tens of MWp). Mainly by application of 'grid-parity' and 'fuel-parity' concepts per country, local market and conventional power plant basis, the global economic market potential for all major PV system segments is derived. PV power plant hybridization potential of all relevant power technologies and the global power plant structure are analyzed regarding technical, economical and geographical feasibility. Key success criteria for hybrid PV power plants are discussed and comprehensively analysed for all adequate power plant technologies, i.e. oil, gas and

  15. Flight Testing of Hybrid Powered Vehicles

    Science.gov (United States)

    Story, George; Arves, Joe

    2006-01-01

    Hybrid Rocket powered vehicles have had a limited number of flights. Most recently in 2004, Scaled Composites had a successful orbital trajectory that put a private vehicle twice to over 62 miles high, the edge of space to win the X-Prize. This endeavor man rates a hybrid system. Hybrids have also been used in a number of one time launch attempts - SET-1, HYSR, HPDP. Hybrids have also been developed for use and flown in target drones. This chapter discusses various flight-test programs that have been conducted, hybrid vehicles that are in development, other hybrid vehicles that have been proposed and some strap-on applications have also been examined.

  16. A new methodology for sizing hybrid photovoltaic-wind energy system using simulation and optimization tools = Uma nova metodologia para dimensionamento de sistemas híbridos de energia (solar-eólica utilizando ferramentas de simulação e otimização

    Directory of Open Access Journals (Sweden)

    Samuel Nelson Melegari de Souza

    2005-01-01

    Full Text Available This paper presents a new methodology for sizing an autonomousphotovoltaic-wind hybrid energy system with battery storage, using simulation and optimization tools. The developed model is useful for energizing remote rural areas and produces a system with minimum cost and high reliability, based on the concept of Loss of Power Supply Probability (LPSP applied for consecutive hours. Some scenarios arecalculated and compared, using different numbers of consecutive hours and different LPSP values. As a result, a complete sizing of the system and a long-term cost evaluation are presented.Este trabalho apresenta uma nova metodologia para dimensionamento de sistemas híbridos de energia (solar-eólica com armazenamento em banco de baterias, utilizando ferramentas de simulação e otimização. O modelo desenvolvido é útil para a energização de áreas ruraisisoladas e resulta num sistema com custo mínimo e alta confiabilidade, baseado no conceito de perda de fornecimento de energia à carga (LPSP aplicado para horas consecutivas. Alguns cenários são calculados e comparados, utilizando-se diferentes períodos de horas consecutivas e diferentes valores de LPSP. Os resultados apresentam um dimensionamento completo do sistema e uma avaliação de custos ao longo de vários anos.

  17. Simulation of hybrid solar power plants

    Science.gov (United States)

    Dieckmann, Simon; Dersch, Jürgen

    2017-06-01

    Hybrid solar power plants have the potential to combine advantages of two different technologies at the cost of increased complexity. The present paper shows the potential of the software greenius for the techno-economic evaluation of hybrid solar power plants and discusses two exemplary scenarios. Depreciated Concentrated Solar Power (CSP) plants based on trough technology can be retrofitted with solar towers in order to reach higher steam cycle temperatures and hence efficiencies. Compared to a newly built tower plant the hybridization of a depreciated trough plant causes about 30% lower LCOE reaching 104 /MWh. The second hybrid scenario combines cost-efficient photovoltaics with dispatchable CSP technology. This hybrid plant offers very high capacity factors up to 69% based on 100% load from 8am to 11pm. The LCOE of the hybrid plant are only slightly lower (174 vs. 186 /MWh) compared to the pure CSP plant because the capital expenditure for thermal storage and power block remains the same while the electricity output is much lower.

  18. Modular supervisory controller for hybrid power systems

    Energy Technology Data Exchange (ETDEWEB)

    Lemos Pereira, A. de

    2000-06-01

    The power supply of remote places has been commonly provided by thermal power plants, usually diesel generators. Although hybrid power systems may constitute the most economical solution in many applications their widespread application to the electrification schemes of remote areas still depends on improvements in the issues of design and operation control. The main limitations of the present hybrid power systems technology, which are identified in this work, are related to the control and supervision of the power system. Therefore this thesis focuses on the modularity of supervisory controllers in order to design cost-competitive and reliable hybrid power systems. The modular supervisory controller created in this project is considered an important part of a system design approach that aims to overcome the technical difficulties of the current engineering practice and contribute to open the market of hybrid power systems. The term modular refers to a set of design characteristics that allows the use of basically the same supervisory controller in different projects. The modularization and standardisation of the controller include several issues such as interfacing components, communication protocols, modelling, programming and control strategies. The modularity can reduce the highly specialised system engineering related to the integration of components, operation and control. It can also avoid the high costs for installation, service and maintenance. A modular algorithm for supervisory controllers has been developed (a Matlab program called SuperCon) using an object-oriented design and it has been tested through several simulations using different hybrid system configurations and different control strategies. This thesis presents a complete control system design process which can be used as the basis for the development and implementation of intelligent and autonomous supervisory controllers for hybrid power systems with modular characteristics. (au)

  19. Wind-solar Hybrid Power System

    OpenAIRE

    Jin, Fei

    2014-01-01

    In the development and utilization of new energy sources, the solar energy and wind energy are paid more attention by various countries, and have become a new field of energy development and utilization of the highest level, the most mature technology, the most widely used and commercial development conditions for new energy. But both the traditional wind power system and solar power system have the characteristic of energy instability. Therefore, wind-solar hybrid power system was proposed i...

  20. Power Quality Application of Hybrid Drivetrain

    OpenAIRE

    Rassõlkin, Anton; Hõimoja, Hardi

    2012-01-01

    This paper presents a study on the power conditioning features of hybrid powertrain, especially regarding diesel-electric locomotives. Equipped with an embarked energy buffer for diesel generator support and utility grid interface, such a locomotive can be considered as a plug-in series hybrid vehicle. The driveline inductive components, like generator and motor windings, and capacitive components like dc link capacitors can be used to provide STATCOM functions, and the energy buffer can be u...

  1. Economic and technical study of a hybrid system (wind-photovoltaic-diesel) for rural electrification in Algeria

    Energy Technology Data Exchange (ETDEWEB)

    Saheb-Koussa, D.; Belhamel, M. [Centre of Development of Renewable energies, Route de l' observatoire, BP.62 Bouzareah, Algiers (Algeria); Haddadi, M. [Laboratoire de Dispositif de Communication et de Conversion Photovoltaique E. N. P, 10 Avenue Hassen Badi, El Harrach, Alger (Algeria)

    2009-07-15

    This paper deals with design of hybrid energy system consisting of wind and photovoltaic with battery storage. A diesel generator is added to ensure continuous power supply and to take care of intermittent nature of wind and photovoltaic. The paper reports results of the technical-economic optimization study of photovoltaic/wind/diesel hybrid with battery storage in Algeria. The primary objective of this study is to estimate the appropriate dimension of stand-alone hybrid photovoltaic/wind/diesel with battery storage that guarantee the energy autonomy of typical remote consumer with lowest cost of energy. A secondary aim is to study the impact of renewable energy potential quality on the system size. The optimum dimensions of the system are defined for six sites in Algeria. In this context, a complete sizing model is developed in Matlab/Simulink V.6.5, able to predict the optimum system configuration. The simulation results indicate that the hybrid system is the best option for all the sites considered in this study. Thus, it provides higher system performance than photovoltaic or wind alone. It s shown that the principal advantage of photovoltaic/wind/diesel hybrid with battery storage are used all together, the reliability of the system is enhanced. The economic analysis has resulted in the calculation of kWh cost of energy for different types of resources and optimized cost of hybrid energy system. It s revealed too that the energy cost depends largely on the renewable energy potential quality. So, our objective for the optimization parameters is not the production cost but the offered service. (author)

  2. Hybrid switch for resonant power converters

    Science.gov (United States)

    Lai, Jih-Sheng; Yu, Wensong

    2014-09-09

    A hybrid switch comprising two semiconductor switches connected in parallel but having different voltage drop characteristics as a function of current facilitates attainment of zero voltage switching and reduces conduction losses to complement reduction of switching losses achieved through zero voltage switching in power converters such as high-current inverters.

  3. Fuel-Cell-Powered Vehicle with Hybrid Power Management

    Science.gov (United States)

    Eichenberg, Dennis J.

    2010-01-01

    Figure 1 depicts a hybrid electric utility vehicle that is powered by hydrogenburning proton-exchange-membrane (PEM) fuel cells operating in conjunction with a metal hydride hydrogen-storage unit. Unlike conventional hybrid electric vehicles, this vehicle utilizes ultracapacitors, rather than batteries, for storing electric energy. This vehicle is a product of continuing efforts to develop the technological discipline known as hybrid power management (HPM), which is oriented toward integration of diverse electric energy-generating, energy-storing, and energy- consuming devices in optimal configurations. Instances of HPM were reported in five prior NASA Tech Briefs articles, though not explicitly labeled as HPM in the first three articles: "Ultracapacitors Store Energy in a Hybrid Electric Vehicle" (LEW-16876), Vol. 24, No. 4 (April 2000), page 63; "Photovoltaic Power Station With Ultracapacitors for Storage" (LEW- 17177), Vol. 27, No. 8 (August 2003), page 38; "Flasher Powered by Photovoltaic Cells and Ultracapacitors" (LEW-17246), Vol. 27, No. 10 (October 2003), page 37; "Hybrid Power Management" (LEW-17520), Vol. 29, No. 12 (December 2005), page 35; and "Ultracapacitor-Powered Cordless Drill" (LEW-18116-1), Vol. 31, No. 8 (August 2007), page 34. To recapitulate from the cited prior articles: The use of ultracapacitors as energy- storage devices lies at the heart of HPM. An ultracapacitor is an electrochemical energy-storage device, but unlike in a conventional rechargeable electrochemical cell or battery, chemical reactions do not take place during operation. Instead, energy is stored electrostatically at an electrode/electrolyte interface. The capacitance per unit volume of an ultracapacitor is much greater than that of a conventional capacitor because its electrodes have much greater surface area per unit volume and the separation between the electrodes is much smaller.

  4. Hybrid power technology for remote military facilities

    Energy Technology Data Exchange (ETDEWEB)

    Chapman, R.N.

    1996-09-01

    The Department of Defense (DoD) operates hundreds of test, evaluation, and training facilities across the US and abroad. Due to the nature of their missions, these facilities are often remote and isolated from the utility grid. The preferred choice for power at these facilities has historically been manned diesel generators. The DoD Photovoltaic Review Committee, estimates that on the order of 350 million gallons of diesel fuel is burned each year to generate the 2000 GWh of electricity required to operate these remote military facilities. Other federal agencies, including the National Park Service and the USDA Forest Service use diesel generators for remote power needs as well. The generation of power diesel generators is both expensive and detrimental to the environment. The augmentation of power from diesel generators with power processing and battery energy storage enhances the efficiency and utilization of the generator resulting in lower fuel consumption and lower generator run- time in proportion to the amount of renewables added. The hybrid technology can both reduce the cost of power and reduce environmental degradation at remote DoD facilities. This paper describes the expected performance and economics of photovoltaic/diesel hybrid systems. Capabilities and status of systems now being installed at DoD facilities are presented along with financing mechanisms available within DoD.

  5. The provision of electricity through a photovoltaic-wind hybrid system in an isolated community in the Jalapao, municipality of Mateiros, state of Tocantins, Brazil; A disponibilizacao de energia eletrica atraves de um sistema hibrido eolico-fotovoltaico em uma comunidade isolada na regiao do Jalapao, municipio de Mateiros, estado do Tocantins

    Energy Technology Data Exchange (ETDEWEB)

    Zukowski Junior, J.C.; Santos, W.F.; Nobrega, S.L. de; Marcon, R.O. [Universidade Luterana do Brasil (CEULP/ULBRA), Palmas, TO (Brazil). Centro Universitario Luterano de Palmas. Curso de Engenharia Agricola], Emails: zukowski@uft.edu.br, olavo@ulbra-to.br, silvestre@ulbra-to.br

    2009-07-01

    Nowadays Brazil has many isolated communities. This isolation occurs mainly due to territorial conditions. Besides this aspect, the lack of structure produces another isolation, much more harmful, the social one. To promote social inclusion and sustainable development, some requirements are essential. Amongst all of them, the provision of electricity is the most prominent. This study aimed to provide electricity to an isolated community in the Jalapao region, Mateiros city, in the state of Tocantins. It was installed a hybrid aeolian-photovoltaic system, with capacity to produce 9676.80 kWh per year. This electricity system aims to improve the production process, so it was installed at the local community workshop. The results indicate that the system can be sustainable if the community makes use of the electricity generation, using it in the production process. (author)

  6. Hybrid electric vehicle power management system

    Energy Technology Data Exchange (ETDEWEB)

    Bissontz, Jay E.

    2015-08-25

    Level voltage levels/states of charge are maintained among a plurality of high voltage DC electrical storage devices/traction battery packs that are arrayed in series to support operation of a hybrid electric vehicle drive train. Each high voltage DC electrical storage device supports a high voltage power bus, to which at least one controllable load is connected, and at least a first lower voltage level electrical distribution system. The rate of power transfer from the high voltage DC electrical storage devices to the at least first lower voltage electrical distribution system is controlled by DC-DC converters.

  7. Hybrid Power Management-Based Vehicle Architecture

    Science.gov (United States)

    Eichenberg, Dennis J.

    2011-01-01

    Hybrid Power Management (HPM) is the integration of diverse, state-of-the-art power devices in an optimal configuration for space and terrestrial applications (s ee figure). The appropriate application and control of the various power devices significantly improves overall system performance and efficiency. The basic vehicle architecture consists of a primary power source, and possibly other power sources, that provides all power to a common energy storage system that is used to power the drive motors and vehicle accessory systems. This architecture also provides power as an emergency power system. Each component is independent, permitting it to be optimized for its intended purpose. The key element of HPM is the energy storage system. All generated power is sent to the energy storage system, and all loads derive their power from that system. This can significantly reduce the power requirement of the primary power source, while increasing the vehicle reliability. Ultracapacitors are ideal for an HPM-based energy storage system due to their exceptionally long cycle life, high reliability, high efficiency, high power density, and excellent low-temperature performance. Multiple power sources and multiple loads are easily incorporated into an HPM-based vehicle. A gas turbine is a good primary power source because of its high efficiency, high power density, long life, high reliability, and ability to operate on a wide range of fuels. An HPM controller maintains optimal control over each vehicle component. This flexible operating system can be applied to all vehicles to considerably improve vehicle efficiency, reliability, safety, security, and performance. The HPM-based vehicle architecture has many advantages over conventional vehicle architectures. Ultracapacitors have a much longer cycle life than batteries, which greatly improves system reliability, reduces life-of-system costs, and reduces environmental impact as ultracapacitors will probably never need to be

  8. HYBRID FUEL CELL-SOLAR CELL SPACE POWER SUBSYSTEM CAPABILITY.

    Science.gov (United States)

    This report outlines the capabilities and limitations of a hybrid solar cell- fuel cell space power subsystem by comparing the proposed hybrid system...to conventional power subsystem devices. The comparisons are based on projected 1968 capability in the areas of primary and secondary battery, fuel ... cell , solar cell, and chemical dynamic power subsystems. The purpose of the investigation was to determine the relative merits of a hybrid power

  9. Intelligent Power Management of hybrid Wind/ Fuel Cell/ Energy Storage Power Generation System

    Directory of Open Access Journals (Sweden)

    A. Hajizadeh

    2013-12-01

    Full Text Available This paper presents an intelligent power management strategy for hybrid wind/ fuel cell/ energy storage power generation system. The dynamic models of wind turbine, fuel cell and energy storage have been used for simulation of hybrid power system. In order to design power flow control strategy, a fuzzy logic control has been implemented to manage the power between power sources. The optimal operation of the hybrid power system is a main goal of designing power management strategy. The hybrid power system is simulated in MATLAB/ SIMIULINK environment and different operating conditions have been considered to evaluate the response of power management strategy.

  10. Hybrid high power femtosecond laser system

    Science.gov (United States)

    Trunov, V. I.; Petrov, V. V.; Pestryakov, E. V.; Kirpichnikov, A. V.

    2006-01-01

    Design of a high-power femtosecond laser system based on hybrid chirped pulse amplification (CPA) technique developed by us is presented. The goal of the hybrid principle is the use of the parametric and laser amplification methods in chirped pulse amplifiers. It makes it possible to amplify the low-cycle pulses with a duration of <= fs to terawatt power with a high contrast and high conversion efficiency of the pump radiation. In a created system the Ti:Sapphire laser with 10 fs pulses at 810 nm and output energy about 1-3 nJ will be used like seed source. The oscillator pulses were stretched to duration of about 500 ps by an all-reflective grating stretcher. Then the stretched pulses are injected into a nondegenerate noncollinear optical parametric amplifier (NOPA) on the two BBO crystals. After amplification in NOPA the residual pump was used in a bow-tie four pass amplifier with hybrid active medium (based on Al II0 3:Ti 3+ and BeAl IIO 4:Ti 3+ crystals). The final stage of the amplification system consists of two channels, namely NIR (820 nm) and short-VIS (410 nm). Numerical simulation has shown that the terawatt level of output power can be achieved also in a short-VIS channel at the pumping of the double-crystal BBO NOPA by the radiation of the fourth harmonic of the Nd:YAG laser at 266 nm. Experimentally parametric amplification in BBO crystals of 30-50 fs pulses were investigated and optimized using SPIDER technique and single-shot autocomelator for the realization of shortest duration 40 fs.

  11. Advanced Power Electronic Interfaces for Distributed Energy Systems Part 1: Systems and Topologies

    Energy Technology Data Exchange (ETDEWEB)

    Kramer, W.; Chakraborty, S.; Kroposki, B.; Thomas, H.

    2008-03-01

    This report summarizes power electronic interfaces for DE applications and the topologies needed for advanced power electronic interfaces. It focuses on photovoltaic, wind, microturbine, fuel cell, internal combustion engine, battery storage, and flywheel storage systems.

  12. Modelling supervisory controller for hybrid power systems

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, A.; Bindner, H.; Lundsager, P. [Risoe National Lab., Roskilde (Denmark); Jannerup, O. [Technical Univ. of Denmark, Dept. of Automation, Lyngby (Denmark)

    1999-03-01

    Supervisory controllers are important to achieve optimal operation of hybrid power systems. The performance and economics of such systems depend mainly on the control strategy for switching on/off components. The modular concept described in this paper is an attempt to design standard supervisory controllers that could be used in different applications, such as village power and telecommunication applications. This paper presents some basic aspects of modelling and design of modular supervisory controllers using the object-oriented modelling technique. The functional abstraction hierarchy technique is used to formulate the control requirements and identify the functions of the control system. The modular algorithm is generic and flexible enough to be used with any system configuration and several goals (different applications). The modularity includes accepting modification of system configuration and goals during operation with minor or no changes in the supervisory controller. (au)

  13. Schemes for photovoltaic-wind electrification in rural areas of Syria

    Energy Technology Data Exchange (ETDEWEB)

    Hamzeh, A.; Kaadan, M. [Damascus Univ. (Syrian Arab Republic)

    2004-07-01

    The electricity authority has, over the years, connected most of population to the electric grid. But for very small villages (2000 villages which are yet to be electrified) and newly established Bedouins settlements (80,000 Bedouin families), the cost of grid connections would be high. The purpose of this paper is to propose planning schemes for off-grid hybrid PV-wind power systems that are suitable for energy requirements and general conditions of Syrian remote small villages. A case study will be introduced where a village with 25 houses and a school is to be supplied by hybrid PV-wind AC systems. The paper presents first a survey and operation evaluation of the PV power systems installed in Syria. Three types of stand-alone PV electrification systems (centralized, individual DC and individual AC systems) with a total capacity of about 100 kW were installed in Syria. Furthermore, the paper presents a summary of the renewable energy development plans, especially PV and PV hybrid systems, included in the renewable energy master plan that was recently performed for Syria. The master plan suggests activities to develop wind, bio-energy, solar, hydro and hybrid systems, which will provide heat and power to Syrian energy needs until 2010. (authors)

  14. High Temperature Power Converters for Military Hybrid Electric Vehicles

    Science.gov (United States)

    2011-08-09

    M) MINI-SYMPOSIUM AUGUST 9-11 DEARBORN, MICHIGAN HIGH TEMPERATURE POWER CONVERTERS FOR MILITARY HYBRID ELECTRIC VEHICLES ABSTRACT...SUBTITLE High Temperature Power Converters for Military Hybrid Electric Vehicles 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6...public release High Temperature Power Converters for Military Hybrid Electric Vehicles Page 2 of 8 I. INTRODUCTION Today, wide bandgap devices

  15. Improvement of adaptive fuzzy control for a photovoltaic/wind/diesel generating system; Taiyoko/furyoku/diesel hatsuden system no saitekigata fuzzy seigyo no kairyo

    Energy Technology Data Exchange (ETDEWEB)

    Nagaike, H.; Kenmoku, Y.; Sakakibara, T. [Toyohashi University of Technology, Aichi (Japan); Nakagawa, S. [Maizuru National College of Technology, Kyoto (Japan); Kawamoto, T. [Shizuoka University, Shizuoka (Japan).Faculty of Engineering

    1996-10-27

    The photovoltaic/wind/diesel generating system that uses a storage battery as auxiliary power has been proposed to supply power from the system to the independent area. In this system, it is important to generate no insufficient power from the viewpoint of effective energy utilization and minimize the fuel consumption of a diesel generator. Authors have proposed the adaptive fuzzy control that changes the shape of the membership function of input variables according to the parameter indicating the system state. However, a parameter was rapidly changed in the conventional method. This badly influences the control. Therefore, the way to determine the parameter that indicates the state of this system was improved. Assume that an input value is set to the average value between a certain point of time and the {Delta}t time as the method for determining a parameter. If the {Delta}t value is lower, the change in a membership function is more effective. As a result, a greater fuel reduction effect was obtained. 4 refs., 8 figs., 1 tab.

  16. A hybrid electromechanical solid state switch for ac power control

    Science.gov (United States)

    1972-01-01

    Bidirectional thyristor coupled to a series of actuator driven electromechanical contacts generates hybrid electromechanical solid state switch for ac power control. Device is useful in power control applications where zero crossover switching is required.

  17. Bimode uninterruptible power supply compatibility in renewable hybrid energy systems

    Energy Technology Data Exchange (ETDEWEB)

    Bower, W. (Sandia National Labs., Albuquerque, NM (USA)); O' Sullivan, G. (Abacus Controls, Inc., Somerville, NJ (USA))

    1990-08-01

    Inverters installed in renewable hybrid energy systems are typically used in a stand-alone mode to supply ac power to loads from battery storage when the engine-generator is not being used. Similarities in topology and in the performance requirements of the standby uninterruptible power supply (UPS) system and the hybrid system suggest the UPS could be used in hybrid energy systems. Another alternative to inverters with add-on charging circuits or standby UPS hardware is the Bimode UPS. The bimode UPS uses common circuitry and power components for dc to ac inversion and battery charging. It also provides an automatic and nearly instantaneous ac power transfer function when the engine-generator is started or stopped. The measured operating and transfer characteristics of a bimode UPS in a utility system and in a hybrid system are presented. The applicability of the bimode UPS to hybrid systems and its compatibility in a PV/engine-generator hybrid system are given.

  18. Dedicated auxiliary power units for Hybrid Electric Vehicles

    NARCIS (Netherlands)

    Mourad, S.; Weijer, C.J.T. van de

    1998-01-01

    The use of a dedicated auxiliary power unit is essential to utilize the potential that hybrid vehicles offer for efficient and ultra-clean transportation. An example of a hybrid project at the TNO Road-Vehicles Research Institute shows the development and the results of a dedicated auxiliary power

  19. Dedicated auxiliary power units for Hybrid Electric Vehicles

    NARCIS (Netherlands)

    Mourad, S.; Weijer, C.J.T. van de

    1998-01-01

    The use of a dedicated auxiliary power unit is essential to utilize the potential that hybrid vehicles offer for efficient and ultra-clean transportation. An example of a hybrid project at the TNO Road-Vehicles Research Institute shows the development and the results of a dedicated auxiliary power u

  20. Portable Hybrid Powered Water Filtration Device

    Directory of Open Access Journals (Sweden)

    Maria Lourdes V. Balansay

    2015-08-01

    Full Text Available The existing water filtration device has features that can be developed to be more useful and functional during emergency situations. The project’s development has been aided by following provisions in PEC, NEC, NEMA and Philippine National Standard for Safe Drinking Water provide standards for the construction of the project. These standards protect both the prototype and the user. These also served as guide for the maintenance of every component. The design of the portable hybrid powered water filtration device shows that the project has more advanced features such as portability and the power supply used such as photovoltaic module solar cells and manually operated generator. This also shows its effectiveness and reliability based on the results of discharging test, water quality test and water production test. Based on analysis of the overall financial aspects, the machine can be profitable and the amount of revenue and operating cost will increase as years pass. Using the proper machine/ tools and methods of fabrication helps in easy assembly of the project. The materials and components used are cost effective and efficient. The best time for charging the battery using solar panel is 9:00 am onwards while the hand crank generator is too slow because the generated current is little. The water filtration device is very efficient regarding the operating hours and water production. The machine may have a great effect to society and economy in generation of clean available water at less cost.

  1. Hybrid simulation: an active power filter case study

    Directory of Open Access Journals (Sweden)

    Y. A. Garcés

    2011-10-01

    Full Text Available The hybrid simulation concept consisting of a combination of computer simulation and laboratory tests. This approach is a cost effective alternative to physically testing the whole system and allows better understanding of complex coupled systems.This paper describes implementing an active power filter (APF hybrid prototype where the source system and load are implemented as a real-time simulation and the system of static power converter acting as an active power filter is implemented in physical hardware. It also confirmed the hybrid simulation results by implementing the simulation in MATLAB-Simulink regarding the same system implemented during the active power filter analysis and design stage.

  2. The Power Quality Compensation Strategy for Power Distribution System Based on Hybrid Parallel Active Power Filters

    Directory of Open Access Journals (Sweden)

    Rachid DEHINI

    2010-12-01

    Full Text Available In this paper, the main aim is to confront the performance of shunt active power filter (SAPF and the shunt hybrid active power filter (SHAPF to achieve flexibility and reliability of the filter devices. Both of the two devices used the classical proportional-integral controller for pulse generation to trigger the inventers MOSFET’s. In the adopted hybrid active filter there is a passive power filter with high power rating to filter the low order harmonies and one active filter with low power rating to filter the other high order harmonies. In order to investigate the effectiveness of (SHAPF, the studies have been accomplished using simulation with the MATLAB-SIMULINK. The results show That (SHAPF is more effective than (SAPF, and has lower cost.

  3. Agent-based power sharing scheme for active hybrid power sources

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Zhenhua [Department of Electrical and Computer Engineering, University of Miami, Coral Gables, FL 33146 (United States)

    2008-02-15

    The active hybridization technique provides an effective approach to combining the best properties of a heterogeneous set of power sources to achieve higher energy density, power density and fuel efficiency. Active hybrid power sources can be used to power hybrid electric vehicles with selected combinations of internal combustion engines, fuel cells, batteries, and/or supercapacitors. They can be deployed in all-electric ships to build a distributed electric power system. They can also be used in a bulk power system to construct an autonomous distributed energy system. An important aspect in designing an active hybrid power source is to find a suitable control strategy that can manage the active power sharing and take advantage of the inherent scalability and robustness benefits of the hybrid system. This paper presents an agent-based power sharing scheme for active hybrid power sources. To demonstrate the effectiveness of the proposed agent-based power sharing scheme, simulation studies are performed for a hybrid power source that can be used in a solar car as the main propulsion power module. Simulation results clearly indicate that the agent-based control framework is effective to coordinate the various energy sources and manage the power/voltage profiles. (author)

  4. Agent-based power sharing scheme for active hybrid power sources

    Science.gov (United States)

    Jiang, Zhenhua

    The active hybridization technique provides an effective approach to combining the best properties of a heterogeneous set of power sources to achieve higher energy density, power density and fuel efficiency. Active hybrid power sources can be used to power hybrid electric vehicles with selected combinations of internal combustion engines, fuel cells, batteries, and/or supercapacitors. They can be deployed in all-electric ships to build a distributed electric power system. They can also be used in a bulk power system to construct an autonomous distributed energy system. An important aspect in designing an active hybrid power source is to find a suitable control strategy that can manage the active power sharing and take advantage of the inherent scalability and robustness benefits of the hybrid system. This paper presents an agent-based power sharing scheme for active hybrid power sources. To demonstrate the effectiveness of the proposed agent-based power sharing scheme, simulation studies are performed for a hybrid power source that can be used in a solar car as the main propulsion power module. Simulation results clearly indicate that the agent-based control framework is effective to coordinate the various energy sources and manage the power/voltage profiles.

  5. Space and power efficient hybrid counters array

    Science.gov (United States)

    Gara, Alan G.; Salapura, Valentina

    2009-05-12

    A hybrid counter array device for counting events. The hybrid counter array includes a first counter portion comprising N counter devices, each counter device for receiving signals representing occurrences of events from an event source and providing a first count value corresponding to a lower order bits of the hybrid counter array. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits of the hybrid counter array. A control device monitors each of the N counter devices of the first counter portion and initiates updating a value of a corresponding second count value stored at the corresponding addressable memory location in the second counter portion. Thus, a combination of the first and second count values provide an instantaneous measure of number of events received.

  6. Hybrid Engine Powered City Car: Fuzzy Controlled Approach

    Science.gov (United States)

    Rahman, Ataur; Mohiuddin, AKM; Hawlader, MNA; Ihsan, Sany

    2017-03-01

    This study describes a fuzzy controlled hybrid engine powered car. The car is powered by the lithium ion battery capacity of 1000 Wh is charged by the 50 cc hybrid engine and power regenerative mode. The engine is operated with lean mixture at 3000 rpm to charge the battery. The regenerative mode that connects with the engine generates electrical power of 500-600 W for the deceleration of car from 90 km/h to 20 km/h. The regenerated electrical power has been used to power the air-conditioning system and to meet the other electrical power. The battery power only used to propel the car. The regenerative power also found charging the battery for longer operation about 40 minutes and more. The design flexibility of this vehicle starts with whole-vehicle integration based on radical light weighting, drag reduction, and accessory efficiency. The energy efficient hybrid engine cut carbon dioxide (CO2) and nitrogen oxides (N2O) emission about 70-80% as the loads on the crankshaft such as cam-follower and its associated rotating components are replaced by electromagnetic systems, and the flywheel, alternator and starter motor are replaced by a motor generator. The vehicle was tested and found that it was able to travel 70 km/litre with the power of hybrid engine.

  7. Stillwater Hybrid Geo-Solar Power Plant Optimization Analyses

    Energy Technology Data Exchange (ETDEWEB)

    Wendt, Daniel S.; Mines, Gregory L.; Turchi, Craig S.; Zhu, Guangdong; Cohan, Sander; Angelini, Lorenzo; Bizzarri, Fabrizio; Consoli, Daniele; De Marzo, Alessio

    2015-09-02

    The Stillwater Power Plant is the first hybrid plant in the world able to bring together a medium-enthalpy geothermal unit with solar thermal and solar photovoltaic systems. Solar field and power plant models have been developed to predict the performance of the Stillwater geothermal / solar-thermal hybrid power plant. The models have been validated using operational data from the Stillwater plant. A preliminary effort to optimize performance of the Stillwater hybrid plant using optical characterization of the solar field has been completed. The Stillwater solar field optical characterization involved measurement of mirror reflectance, mirror slope error, and receiver position error. The measurements indicate that the solar field may generate 9% less energy than the design value if an appropriate tracking offset is not employed. A perfect tracking offset algorithm may be able to boost the solar field performance by about 15%. The validated Stillwater hybrid plant models were used to evaluate hybrid plant operating strategies including turbine IGV position optimization, ACC fan speed and turbine IGV position optimization, turbine inlet entropy control using optimization of multiple process variables, and mixed working fluid substitution. The hybrid plant models predict that each of these operating strategies could increase net power generation relative to the baseline Stillwater hybrid plant operations.

  8. Hybrid wind-power-distillation plant

    OpenAIRE

    Ninić Neven; Klarin Branko; Tolj Ivan

    2012-01-01

    This paper reports and elaborates on the idea of a solar distiller and an offshore wind power plant operating together. The subject under discussion is a single-stage solar distillation plant with vaporization, using adiabatic expansion in the gravitational field inside a wind power plant supporting column. This scheme divides investment costs for electric power and distillate production. In the region of the Adriatic Sea, all electric power produced could be “converted” to hydrogen usi...

  9. Ultralight Solar Powered Hybrid Research Drone

    CERN Document Server

    Singer, Csaba

    2013-01-01

    A planetary research drone is proposed, which is capable for vertical takeoff and landing. A hybrid flight concept utilizing static lift enables the exploration over ground. The static lift is achieved with a lighter than CO2 gas like air, He or H2.

  10. A hybrid approach to space power control

    Science.gov (United States)

    Gholdston, E. W.; Janik, D. F.; Newton, K. A.

    1990-01-01

    Conventional control systems have traditionally been utilized for space-based power designs. However, the use of expert systems is becoming important for NASA applications. Rocketdyne has been pursuing the development of expert systems to aid and enhance control designs of space-based power systems. The need for integrated expert systems is vital for the development of autonomous power systems.

  11. Control approach for comfortable power shifting in hybrid transmissions - ML 450 hybrid

    Energy Technology Data Exchange (ETDEWEB)

    Saenger Zetina, Siegfried; Neiss, Konstantin [Daimler AG, Hybrid Development Center, Troy, MI (United States)

    2008-07-01

    The comfortable shifting control in a luxury class vehicle is extremely important, due to competitive automatic transmissions with torque converters; clutch automated manual transmissions and dual clutch transmissions. Hybrid transmissions play a key role in comfort and performance enhancement while at the same time being fuel efficient with the aid of electric machines and battery packs. Here, the alternative to conventional add-on hybrid power head transmissions: the power split hybrid transmission is studied. As a practical example, the Two Mode of the Hybrid Development Center is used within the ML450 Hybrid. For achieving a smooth shifting, there are model based algorithms needed. As objective measure to evaluate the shifting the VDV (Vibration Dose Value) is used. (orig.)

  12. Hybrid wind-power-distillation plant

    Directory of Open Access Journals (Sweden)

    Ninić Neven

    2012-01-01

    Full Text Available This paper reports and elaborates on the idea of a solar distiller and an offshore wind power plant operating together. The subject under discussion is a single-stage solar distillation plant with vaporization, using adiabatic expansion in the gravitational field inside a wind power plant supporting column. This scheme divides investment costs for electric power and distillate production. In the region of the Adriatic Sea, all electric power produced could be “converted” to hydrogen using less than 10% of the distillate produced.

  13. Power Quality Improvement Using Hybrid Power Flow Controller in Power System

    Directory of Open Access Journals (Sweden)

    Manidhar Thula ,

    2014-01-01

    Full Text Available This paper discusses the applicability of Hybrid Power Flow Controller (HPFC as an alternative to Unified Power Flow Controller (UPFC for improvement of power system performance. UPFC is a flexible AC transmission system (FACTS device containing two switching converters, one in series and one in shunt. To configure the HPFC, one of the switching converters of the UPFC is replaced by thyristor controlled variable impedances, thus reducing the cost. In this paper, the HPFC has been configured by multilevel Voltage Source Converter (VSC used for the shunt compensation branches and a thyristor controlled variable impedance used for series compensation. It is shown that with suitable control the HPFC can inject a voltage of required magnitude in series with the line at any desired angle, just like UPFC. This helps in providing compensation equivalent to UPFC and improving the steady state stability limits of the power system.

  14. Renewable energy for professional applications: a guide to implementing off-grid power supplies in the UK

    Energy Technology Data Exchange (ETDEWEB)

    Paish, O.; Oldach, R.

    2002-09-01

    These guidelines are intended to help those considering renewable energy systems to supply power to off-grid applications without access to the UK mains electricity network. The guidelines consider: examples of renewable energy systems used applications with a low power demand in the UK; renewable energy technologies relevant to off-grid applications (solar photovoltaics, wind generators, micro-hydro turbines and hybrid systems); nine steps for project implementation; defining and optimising the load application; estimating energy resources when using solar energy, wind power and hydro power; general rules of thumb when choosing a power source; system components such as batteries, inverters, support structure and civil works; basic system sizing calculations; developing a specification and contacting suppliers; checking equipment, installation and commissioning; legal and other non-technical issues; operating issues such as maintenance and safety; and selected case studies from the UK.

  15. Hybrid anisotropic materials for wind power turbine blades

    CERN Document Server

    Golfman, Yosif

    2012-01-01

    Based on rapid technological developments in wind power, governments and energy corporations are aggressively investing in this natural resource. Illustrating some of the crucial new breakthroughs in structural design and application of wind energy generation machinery, Hybrid Anisotropic Materials for Wind Power Turbine Blades explores new automated, repeatable production techniques that expand the use of robotics and process controls. These practices are intended to ensure cheaper fabrication of less-defective anisotropic material composites used to manufacture power turbine blades. This boo

  16. Short-Term Planning of Hybrid Power System

    Science.gov (United States)

    Knežević, Goran; Baus, Zoran; Nikolovski, Srete

    2016-07-01

    In this paper short-term planning algorithm for hybrid power system consist of different types of cascade hydropower plants (run-of-the river, pumped storage, conventional), thermal power plants (coal-fired power plants, combined cycle gas-fired power plants) and wind farms is presented. The optimization process provides a joint bid of the hybrid system, and thus making the operation schedule of hydro and thermal power plants, the operation condition of pumped-storage hydropower plants with the aim of maximizing profits on day ahead market, according to expected hourly electricity prices, the expected local water inflow in certain hydropower plants, and the expected production of electrical energy from the wind farm, taking into account previously contracted bilateral agreement for electricity generation. Optimization process is formulated as hourly-discretized mixed integer linear optimization problem. Optimization model is applied on the case study in order to show general features of the developed model.

  17. Probabilistic Wind Power Forecasting with Hybrid Artificial Neural Networks

    DEFF Research Database (Denmark)

    Wan, Can; Song, Yonghua; Xu, Zhao

    2016-01-01

    probabilities of prediction errors provide an alternative yet effective solution. This article proposes a hybrid artificial neural network approach to generate prediction intervals of wind power. An extreme learning machine is applied to conduct point prediction of wind power and estimate model uncertainties...... via a bootstrap technique. Subsequently, the maximum likelihood estimation method is employed to construct a distinct neural network to estimate the noise variance of forecasting results. The proposed approach has been tested on multi-step forecasting of high-resolution (10-min) wind power using...... actual wind power data from Denmark. The numerical results demonstrate that the proposed hybrid artificial neural network approach is effective and efficient for probabilistic forecasting of wind power and has high potential in practical applications....

  18. Hybrid Photovoltaic-Hydrogen Power Conditioning System

    Science.gov (United States)

    Garrigos, A.; Blanes, J. M.; Carrasco, J. A.; Maset, E.; Ejea, J. B.; Ferreres, A.; Sanchis, E.

    2011-10-01

    This paper explores a power conditioning unit for photovoltaic/hydrogen based energy systems. Similar power conversion techniques, compared to traditional space power systems, are applied. An S4R regulator is devised with an unregulated battery bus as primary output and a secondary path to feed and electrolyser. A modular fuel cell converter completes the system and it operates when photovoltaic energy is not available or load demand exceeds solar power, i. e. like a traditional BDR. An ancillary battery keeps the unregulated bus voltage distributed in the system and it also aids the fuel cell during transients or start-up due to its limited speed. A 1kW breadboard has been designed and implemented to corroborate the proposed system.

  19. Performance Analysis of a Hybrid Power Cutting System for Roadheader

    Directory of Open Access Journals (Sweden)

    Yang Yang

    2017-01-01

    Full Text Available An electrohydraulic hybrid power cutting transmission system for roadheader under specific working condition was proposed in this paper. The overall model for the new system composed of an electric motor model, a hydraulic pump-motor model, a torsional planetary set model, and a hybrid power train model was established. The working mode characteristics were simulated under the conditions of taking the effect of cutting picks into account. The advantages of new hybrid power cutting system about the dynamic response under shock load were investigated compared with the traditional cutting system. The results illustrated that the hybrid power system had an obvious cushioning in terms of the dynamic load of cutting electric motor and planetary gear set. Besides, the hydraulic motor could provide an auxiliary power to improve the performance of the electric motor. With further analysis, a dynamic load was found to have a high relation to the stiffness and damping of coupling in the transmission train. The results could be a useful guide for the design of cutting transmission of roadheader.

  20. Photovoltaic / Diesel / Battery Hybrid Power Supply System

    CSIR Research Space (South Africa)

    Tazvinga, Henerica

    2010-10-01

    Full Text Available electricity being allocated to the more important urban sector. The relatively low energy demand in rural areas does not compensate the cost of long-range transmission lines from the national grid. This justifies the use of more decentralised forms of power...

  1. Design and control of hybrid active power filters

    CERN Document Server

    Lam, Chi-Seng

    2014-01-01

    Design and Control of Hybrid Active Power Filters presents an overview of the current quality problems and their compensators. To get a balance between the system cost and performance, hybrid active power filters (HAPFs) are valuable. The book presents the coverage of resonance phenomena prevention capability, filtering performance and system robustness analysis of HAPF; nonlinear inverter current slope characteristics and their linear operation region requirement analysis of the hysteresis PWM for the HAPF; minimum inverter capacity design procedure of HAPF, adaptive dc-link voltage controller for the HAPF and the real design example of a 220V 10kVA HAPF, in which the system performance analysis method, minimum dc voltage deduction concept and adaptive dc voltage idea can be further extended into the other active compensators, such as APF, static synchronous compensator STATCOM, etc. This book will benefit researchers, graduate students, and electrical power engineers in the field of power-quality compensati...

  2. Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation

    Energy Technology Data Exchange (ETDEWEB)

    Faress Rahman; Nguyen Minh

    2004-01-04

    This report summarizes the work performed by Hybrid Power Generation Systems, LLC (HPGS) during the July 2003 to December 2003 reporting period under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL) entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. The main objective of this project is to develop and demonstrate the feasibility of a highly efficient hybrid system integrating a planar Solid Oxide Fuel Cell (SOFC) and a micro-turbine. In addition, an activity included in this program focuses on the development of an integrated coal gasification fuel cell system concept based on planar SOFC technology. Also, another activity included in this program focuses on the development of SOFC scale up strategies.

  3. THERMOELECTRIC AND MICROBATTERY HYBRID SYSTEM WITH ITS POWER MANAGEMENT

    OpenAIRE

    2006-01-01

    Submitted on behalf of EDA Publishing Association (http://irevues.inist.fr/handle/2042/5920); International audience; Integration of a power source with a MEMS to obtain an autonomous or remote system is a very challenging task. Such a device is currently being developed. It consists in hybriding an energy storage system (thin film solid state battery) with a scavenging energy system (thermogenerator) in a very small volume. It requires also power management to both control charge of the batt...

  4. Load flow computations in hybrid transmission - distributed power systems

    NARCIS (Netherlands)

    Wobbes, E.D.; Lahaye, D.J.P.

    2013-01-01

    We interconnect transmission and distribution power systems and perform load flow computations in the hybrid network. In the largest example we managed to build, fifty copies of a distribution network consisting of fifteen nodes is connected to the UCTE study model, resulting in a system consisting

  5. Optimization strategy for element sizing in hybrid power systems

    Science.gov (United States)

    del Real, Alejandro J.; Arce, Alicia; Bordons, Carlos

    This paper presents a procedure to evaluate the optimal element sizing of hybrid power systems. In order to generalize the problem, this work exploits the "energy hub" formulation previously presented in the literature, defining an energy hub as an interface among energy producers, consumers and the transportation infrastructure. The resulting optimization minimizes an objective function which is based on costs and efficiencies of the system elements, while taking into account the hub model, energy and power constraints and estimated operational conditions, such as energy prices, input power flow availability and output energy demand. The resulting optimal architecture also constitutes a framework for further real-time control designs. Moreover, an example of a hybrid storage system is considered. In particular, the architecture of a hybrid plant incorporating a wind generator, batteries and intermediate hydrogen storage is optimized, based on real wind data and averaged residential demands, also taking into account possible estimation errors. The hydrogen system integrates an electrolyzer, a fuel cell stack and hydrogen tanks. The resulting optimal cost of such hybrid power plant is compared with the equivalent hydrogen-only and battery-only systems, showing improvements in investment costs of almost 30% in the worst case.

  6. Optimization strategy for element sizing in hybrid power systems

    Energy Technology Data Exchange (ETDEWEB)

    del Real, Alejandro J.; Arce, Alicia; Bordons, Carlos [Departamento de Ingenieria de Sistemas y Automatica, Universidad de Sevilla, 41092 Sevilla (Spain)

    2009-08-01

    This paper presents a procedure to evaluate the optimal element sizing of hybrid power systems. In order to generalize the problem, this work exploits the ''energy hub'' formulation previously presented in the literature, defining an energy hub as an interface among energy producers, consumers and the transportation infrastructure. The resulting optimization minimizes an objective function which is based on costs and efficiencies of the system elements, while taking into account the hub model, energy and power constraints and estimated operational conditions, such as energy prices, input power flow availability and output energy demand. The resulting optimal architecture also constitutes a framework for further real-time control designs. Moreover, an example of a hybrid storage system is considered. In particular, the architecture of a hybrid plant incorporating a wind generator, batteries and intermediate hydrogen storage is optimized, based on real wind data and averaged residential demands, also taking into account possible estimation errors. The hydrogen system integrates an electrolyzer, a fuel cell stack and hydrogen tanks. The resulting optimal cost of such hybrid power plant is compared with the equivalent hydrogen-only and battery-only systems, showing improvements in investment costs of almost 30% in the worst case. (author)

  7. ADОPTIVE CONTROL OF THE HYBRID VEHICLE POWER UNIT

    Directory of Open Access Journals (Sweden)

    S. Serikov

    2014-10-01

    Full Text Available The problem of adaptive control of the hybrid vehicle power unit, which makes it possible to minimize the quality criterion under constraints on the state parameters and the control vector is considered. A formal statement of the optimization problem is given. The solution of this problem by the method of neural network control based on the adaptive criticism is considered.

  8. Bipolar lead-acid power source (BILAPS) for hybrid vehicles

    NARCIS (Netherlands)

    Schmal, D.; Saakes, M.; Mourad, S.; Have, P. ten

    1999-01-01

    In hybrid electric vehicles (HEV's) the requirements on batteries for energy storage are completely different from those in battery powered electric vehicles (BEV's). In order to come to a succesful development of HEV's, beside fullfilling the technical requirements, the battery has to have a long

  9. Bipolar lead-acid power source (BILAPS) for hybrid vehicles

    NARCIS (Netherlands)

    Schmal, D.; Saakes, M.; Mourad, S.; Have, P. ten

    1999-01-01

    In hybrid electric vehicles (HEV's) the requirements on batteries for energy storage are completely different from those in battery powered electric vehicles (BEV's). In order to come to a succesful development of HEV's, beside fullfilling the technical requirements, the battery has to have a long l

  10. Bipolar lead-acid power source (BILAPS) for hybrid vehicles

    NARCIS (Netherlands)

    Schmal, D.; Saakes, M.

    1998-01-01

    In hybrid electric vehicles (HEV's) the requirements on batteries for energy storage are completely different from those in battery powered electric vehicles (BEV's). In order to come to a succesful development of HEV's, beside fullfilling the technical requirements, the battery has to have a long l

  11. Piezoelectric-based hybrid reserve power sources for munitions

    Science.gov (United States)

    Rastegar, J.; Kwok, P.

    2017-04-01

    Reserve power sources are used extensively in munitions and other devices, such as emergency devices or remote sensors that need to be powered only once and for a relatively short duration. Current chemical reserve power sources, including thermal batteries and liquid reserve batteries sometimes require more than 100 msec to become fully activated. In many applications, however, electrical energy is required in a few msec following the launch event. In such applications, other power sources are needed to provide power until the reserve battery is fully activated. The amount of electrical energy that is required by most munitions before chemical reserve batteries are fully activated is generally small and can be provided by properly designed piezoelectric-based energy harvesting devices. In this paper, the development of a hybrid reserve power source that is constructed by integration of a piezoelectric-based energy harvesting device with a reserve battery to provide power almost instantaneously upon munitions firing or other similar events is being reported. A review of the state of the art in piezoelectric-based electrical energy harvesting methods and devices and their charge collection electronics for use in the developed hybrid power sources is provided together with the results of testing of the piezoelectric component of the power source and its electronic safety and charge collection electronics.

  12. Piezoelectric-based hybrid reserve power sources for munitions

    Science.gov (United States)

    Rastegar, Jahangir; Pereira, Carlos M.; Feng, Dake

    2016-05-01

    Reserve power sources are used extensively in munitions and other devices such as emergency devices or remote sensors that have to be powered only once and for a relatively short duration. Current chemical reserve power sources, including thermal batteries and liquid reserve batteries require sometimes in excess of 100 msec to become fully activated. In many applications, however, electrical energy is required in a few msec following the launch event. In such applications, other power sources have to be provided to provide power until the reserve battery is fully activated. The amount of electrical energy that is required by most munitions before chemical reserve batteries are fully activated is generally small and can be provided by properly designed piezoelectric-based energy harvesting devices. In this paper the development of a hybrid reserve power source obtained by the integration of a piezoelectric-based energy harvesting device with a reserve battery that can provide power almost instantaneously upon munitions firing or other similar events is being reported. A review of the state of the art in piezoelectric-based electrical energy harvesting methods and devices and their charge collection electronics for use in the developed hybrid power sources is also provided together with the results of testing of the piezoelectric component of the power source and its electronic safety and charge collection electronics.

  13. Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation

    Energy Technology Data Exchange (ETDEWEB)

    David Deangelis; Rich Depuy; Debashis Dey; Georgia Karvountzi; Nguyen Minh; Max Peter; Faress Rahman; Pavel Sokolov; Deliang Yang

    2004-09-30

    This report summarizes the work performed by Hybrid Power Generation Systems, LLC (HPGS) during the April to October 2004 reporting period in Task 2.3 (SOFC Scaleup for Hybrid and Fuel Cell Systems) under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL), entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. This study analyzes the performance and economics of power generation systems for central power generation application based on Solid Oxide Fuel Cell (SOFC) technology and fueled by natural gas. The main objective of this task is to develop credible scale up strategies for large solid oxide fuel cell-gas turbine systems. System concepts that integrate a SOFC with a gas turbine were developed and analyzed for plant sizes in excess of 20 MW. A 25 MW plant configuration was selected with projected system efficiency of over 65% and a factory cost of under $400/kW. The plant design is modular and can be scaled to both higher and lower plant power ratings. Technology gaps and required engineering development efforts were identified and evaluated.

  14. Solar central receiver hybrid - A cost effective future power alternative

    Science.gov (United States)

    Beshore, D. G.; Bolton, C. N.; Montague, J. E.

    1980-05-01

    System analyses and conceptual designs of solar central receiver hybrid concepts using molten salt (60% NaNO3, 40% KNO3 by weight) and fossil fired nonsolar energy sources (coal, oil, or gas) have been performed. Analyses have developed plant configurations with various solar energy storage capacities and fossil fuels. Economic analyses support the final configuration selection based on minimization of the cost of energy produced from the plant. A 500 MWe commercial plant size installed for a 1990 initial year of operation is competitive with new coal, oil, and nuclear power generation sources. This hybrid plant will save an estimated 5 million barrels of oil per year.

  15. A Hybrid Optimization Method for Reactive Power and Voltage Control Considering Power Loss Minimization

    DEFF Research Database (Denmark)

    Liu, Chengxi; Qin, Nan; Bak, Claus Leth;

    2015-01-01

    This paper proposes a hybrid optimization method to optimally control the voltage and reactive power with minimum power loss in transmission grid. This approach is used for the Danish automatic voltage control (AVC) system which is typically a non-linear non-convex problem mixed with both continu...

  16. Thermoeconomic Analysis of Hybrid Power Plant Concepts for Geothermal Combined Heat and Power Generation

    Directory of Open Access Journals (Sweden)

    Florian Heberle

    2014-07-01

    Full Text Available We present a thermo-economic analysis for a low-temperature Organic Rankine Cycle (ORC in a combined heat and power generation (CHP case. For the hybrid power plant, thermal energy input is provided by a geothermal resource coupled with the exhaust gases of a biogas engine. A comparison to alternative geothermal CHP concepts is performed by considering variable parameters like ORC working fluid, supply temperature of the heating network or geothermal water temperature. Second law efficiency as well as economic parameters show that hybrid power plants are more efficient compared to conventional CHP concepts or separate use of the energy sources.

  17. Research on hybrid power filter of 6 kV power grid in coal mine

    Institute of Scientific and Technical Information of China (English)

    WANG Yu-feng; LI Jian

    2010-01-01

    Studied the harmonic control of the 6 kV power grid in a coal mine substation.Taking harmonic suppression and reactive power compensation into account, and complying with the economic and efficient technical line of the smart grid, a new hybrid active filter was proposed and applied to the power grid in the coal mine with the advantages such as large capacity, low cost and low loss. In order to improve detection speed and reduce the succeeding errors to improve the filtering performance of the active power filter,the DFT (Discrete Fourier Transform) sliding window algorithm based on coordinate transformation and improved hysteresis control method was proposed. The Matlab simulation results show that the hybrid active filter is satisfactory, can improve the grid power factor and can meet the requirements of improving the power quality in the coal mine.

  18. Robust Power Management Control for Stand-Alone Hybrid Power Generation System

    Science.gov (United States)

    Kamal, Elkhatib; Adouane, Lounis; Aitouche, Abdel; Mohammed, Walaa

    2017-01-01

    This paper presents a new robust fuzzy control of energy management strategy for the stand-alone hybrid power systems. It consists of two levels named centralized fuzzy supervisory control which generates the power references for each decentralized robust fuzzy control. Hybrid power systems comprises: a photovoltaic panel and wind turbine as renewable sources, a micro turbine generator and a battery storage system. The proposed control strategy is able to satisfy the load requirements based on a fuzzy supervisor controller and manage power flows between the different energy sources and the storage unit by respecting the state of charge and the variation of wind speed and irradiance. Centralized controller is designed based on If-Then fuzzy rules to manage and optimize the hybrid power system production by generating the reference power for photovoltaic panel and wind turbine. Decentralized controller is based on the Takagi-Sugeno fuzzy model and permits us to stabilize each photovoltaic panel and wind turbine in presence of disturbances and parametric uncertainties and to optimize the tracking reference which is given by the centralized controller level. The sufficient conditions stability are formulated in the format of linear matrix inequalities using the Lyapunov stability theory. The effectiveness of the proposed Strategy is finally demonstrated through a SAHPS (stand-alone hybrid power systems) to illustrate the effectiveness of the overall proposed method.

  19. Reactive power control of wind-diesel-micro-hydro hybrid power systems using matlab/simulink

    Energy Technology Data Exchange (ETDEWEB)

    Bansal, R.C.; Bhatti, T.S.; Kothari, D.P.; Bhat, S. [Birla Inst. of Technology and Science, Pilani (India); Indian Inst. of Technology, New Delhi (India). Centre for Energy Studies; Visvesvaraya National Inst. of Technology, Nagpur (IN). Dept. of Electrical Engineering)

    2005-07-01

    This paper presents reactive power control of isolated wind-diesel-micro-hydro hybrid power system for realistic load disturbance using matlab/simulink. The mathematical model of the system based on matlab/simulink is developed. Reactive power control performance is compared using three different types of Static VAR Compensators (SVC). Transient responses for step plus normally distributed or band limited white noise random change in load have also been presented in this paper. (Author)

  20. DESIGN CONSIDERATIONS FOR SERIES HYBRID ACTIVE POWER FILTER

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Some important factors for designing a series hybrid active power filter (SHAPF) are presented in this paper for the case when the load is varied in a wide range and/or the source voltage is seriously distorted. Special design of passive filters, adaptive control of parameter and multi variant control are discussed in detail. The filter is stable, has good performance, and causes small capacitive reactive current. The simulation and experimental results accorded with the theoretical analysis results.

  1. Hybrid HVDC circuit breaker with self-powered gate drives

    OpenAIRE

    Effah, Francis Boafo; Watson, Alan James; Ji, Chao; Amankwah, Emmanuel K.; Johnson, Christopher Mark; Davidson, Colin; Clare, Jon C.

    2016-01-01

    The ever increasing electric power demand and the advent of renewable energy sources have revived the interest in high-voltage direct current (HVDC) multi-terminal networks. However, the absence of a suitable circuit breaker or fault tolerant VSC station topologies with the required characteristics (such as operating speed) have, until recently, been an obstacle in the development of large scale multi-terminal networks for HVDC. This paper presents a hybrid HVDC circuit breaker concept which...

  2. Hybrid HVDC circuit breaker with self-powered gate drives

    OpenAIRE

    Effah, Francis Boafo; Watson, Alan James; Ji, Chao; Amankwah, Emmanuel K.; Johnson, Christopher Mark; Davidson, Colin; Clare, Jon C.

    2016-01-01

    The ever increasing electric power demand and the advent of renewable energy sources have revived the interest in high-voltage direct current (HVDC) multi-terminal networks. However, the absence of a suitable circuit breaker or fault tolerant VSC station topologies with the required characteristics (such as operating speed) have, until recently, been an obstacle in the development of large scale multi-terminal networks for HVDC. This paper presents a hybrid HVDC circuit breaker concept which ...

  3. Modeling, analysis and control of fuel cell hybrid power systems

    Science.gov (United States)

    Suh, Kyung Won

    Transient performance is a key characteristic of fuel cells, that is sometimes more critical than efficiency, due to the importance of accepting unpredictable electric loads. To fulfill the transient requirement in vehicle propulsion and portable fuel cell applications, a fuel cell stack is typically coupled with a battery through a DC/DC converter to form a hybrid power system. Although many power management strategies already exist, they all rely on low level controllers that realize the power split. In this dissertation we design controllers that realize various power split strategies by directly manipulating physical actuators (low level commands). We maintain the causality of the electric dynamics (voltage and current) and investigate how the electric architecture affects the hybridization level and the power management. We first establish the performance limitations associated with a stand-alone and power-autonomous fuel cell system that is not supplemented by an additional energy storage and powers all its auxiliary components by itself. Specifically, we examine the transient performance in fuel cell power delivery as it is limited by the air supplied by a compressor driven by the fuel cell itself. The performance limitations arise from the intrinsic coupling in the fluid and electrical domain between the compressor and the fuel cell stack. Feedforward and feedback control strategies are used to demonstrate these limitations analytically and with simulations. Experimental tests on a small commercial fuel cell auxiliary power unit (APU) confirm the dynamics and the identified limitations. The dynamics associated with the integration of a fuel cell system and a DC/DC converter is then investigated. Decentralized and fully centralized (using linear quadratic techniques) controllers are designed to regulate the power system voltage and to prevent fuel cell oxygen starvation. Regulating these two performance variables is a difficult task and requires a compromise

  4. Improvement of Power Quality Using a Hybrid Interline UPQC

    Directory of Open Access Journals (Sweden)

    M.K.Elango

    2014-05-01

    Full Text Available This paper proposed the reduced rating star connected transformer based interline unified power quality conditioner. This work comprises of unified power quality conditioner connected between the two feeders, star connected transformer and LC filter. This hybrid approach significantly improves the performance of UPQC under unbalance source voltage condition. The UPQC adopted to compensate current and voltage-quality problems of sensitive loads and suppressing the load current harmonics under distorted supply conditions. The series converter control strategy is based on the fuzzy-logic controller. The extensive simulation results have carried out in MATLAB/Simulink environment power system blockset toolboxes. From the results it has shown that hybrid interline UPQC achieves superior capability of mitigating the effects of voltage sag/swell and suppressing the load current harmonics, phase current harmonics and neutral current under distorted supply conditions. To validate the results produced by the proposed method, it is compared with the conventional UPQC method and better results obtained from the hybrid approach.

  5. Scalable and Power Efficient Data Analytics for Hybrid Exascale Systems

    Energy Technology Data Exchange (ETDEWEB)

    Choudhary, Alok [Northwestern Univ., Evanston, IL (United States); Samatova, Nagiza [North Carolina State Univ., Raleigh, NC (United States); Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Wu, Kesheng [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Liao, Wei-keng [Northwestern Univ., Evanston, IL (United States)

    2015-03-19

    This project developed a generic and optimized set of core data analytics functions. These functions organically consolidate a broad constellation of high performance analytical pipelines. As the architectures of emerging HPC systems become inherently heterogeneous, there is a need to design algorithms for data analysis kernels accelerated on hybrid multi-node, multi-core HPC architectures comprised of a mix of CPUs, GPUs, and SSDs. Furthermore, the power-aware trend drives the advances in our performance-energy tradeoff analysis framework which enables our data analysis kernels algorithms and software to be parameterized so that users can choose the right power-performance optimizations.

  6. Optimal Power Scheduling for an Islanded Hybrid Microgrid

    DEFF Research Database (Denmark)

    Hernández, Adriana Carolina Luna; Aldana, Nelson Leonardo Diaz; Savaghebi, Mehdi

    2016-01-01

    A microgrid is a system that integrates energy generation, energy storage, and loads and it is able to operate either in interconnected or islanded mode. Energy resources should be scheduled to supply the load properly in order to coordinate optimally the power exchange within the microgrid...... according to a defined objective function. In this paper, an optimal power scheduling for generation and demand side is presented to manage an islanded hybrid PV-wind-battery microgrid implemented in Shanghai-China. The optimization is addressed through a Mixed-Integer Linear Programming (MILP) mathematical......SPACE1006) in which a scaled down model of this microgrid is emulated....

  7. PEFC stacks as power sources for hybrid propulsion systems

    Energy Technology Data Exchange (ETDEWEB)

    Corbo, P.; Migliardini, F.; Veneri, O. [Istituto Motori of Italian National Research Council, Via Marconi 8, 80125 Napoli (Italy)

    2009-05-15

    In this paper the performance of two polymeric electrolyte fuel cell systems (FCS) for hybrid power trains are presented and discussed. In particular, an experimental analysis was effected on 2.4 and 20 kW stacks with the aim to investigate the energy management issues of the two FCSs for utilization as power sources in electric power trains for scooter and minibus, respectively. The stack characterizations permitted the effect of the main operative variables (temperature, pressure and stoichiometric ratio) on mean power density of cells to be evaluated. The FCS efficiency was evaluated and compared for the two traction systems, individuating the optimal operative conditions for automotive application and specifying the energy losses of the auxiliary components. The efficiency of both fuel cell systems resulted higher than 40% in a wide range of loads (100-600 mA/cm{sup 2}), with maximum values close to 50%. The experimental characterization of the two power trains was carried out on dynamic test benches, able to simulate the behaviour of the two vehicles on the European R40 driving cycle. The characterization of the two propulsion systems on R40 driving cycle evidenced that the overall efficiency was not affected significantly by the hybrid configuration adopted, as the efficiency values ranged from 27 to 29% in the different procedures analyzed. (author)

  8. Continual Energy Management System of Proton Exchange Membrane Fuel Cell Hybrid Power Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Ren Yuan

    2016-01-01

    Full Text Available Current research status in energy management of Proton Exchange Membrane (PEM fuel cell hybrid power electric vehicles are first described in this paper, and then build the PEMFC/ lithium-ion battery/ ultra-capacitor hybrid system model. The paper analysis the key factors of the continuous power available in PEM fuel cell hybrid power electric vehicle and hybrid power system working status under different driving modes. In the end this paper gives the working flow chart of the hybrid power system and concludes the three items of the system performance analysis.

  9. Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen Minh

    2005-12-01

    This report summarizes the work performed by Hybrid Power Generation Systems, LLC (HPGS) under Cooperative Agreement DE-FC2601NT40779 for the US Department of Energy, National Energy Technology Laboratory (DoE/NETL) entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. The main objective of this project is to develop and demonstrate the feasibility of a highly efficient hybrid system integrating a planar Solid Oxide Fuel Cell (SOFC) and a gas turbine. A conceptual hybrid system design was selected for analysis and evaluation. The selected system is estimated to have over 65% system efficiency, a first cost of approximately $650/kW, and a cost of electricity of 8.4 cents/kW-hr. A control strategy and conceptual control design have been developed for the system. A number of SOFC module tests have been completed to evaluate the pressure impact to performance stability. The results show that the operating pressure accelerates the performance degradation. Several experiments were conducted to explore the effects of pressure on carbon formation. Experimental observations on a functioning cell have verified that carbon deposition does not occur in the cell at steam-to-carbon ratios lower than the steady-state design point for hybrid systems. Heat exchanger design, fabrication and performance testing as well as oxidation testing to support heat exchanger life analysis were also conducted. Performance tests of the prototype heat exchanger yielded heat transfer and pressure drop characteristics consistent with the heat exchanger specification. Multicell stacks have been tested and performance maps were obtained under hybrid operating conditions. Successful and repeatable fabrication of large (>12-inch diameter) planar SOFC cells was demonstrated using the tape calendering process. A number of large area cells and stacks were successfully performance tested at ambient and pressurized conditions. A 25 MW plant configuration was

  10. Hybrid intelligent monironing systems for thermal power plant trips

    Science.gov (United States)

    Barsoum, Nader; Ismail, Firas Basim

    2012-11-01

    Steam boiler is one of the main equipment in thermal power plants. If the steam boiler trips it may lead to entire shutdown of the plant, which is economically burdensome. Early boiler trips monitoring is crucial to maintain normal and safe operational conditions. In the present work two artificial intelligent monitoring systems specialized in boiler trips have been proposed and coded within the MATLAB environment. The training and validation of the two systems has been performed using real operational data captured from the plant control system of selected power plant. An integrated plant data preparation framework for seven boiler trips with related operational variables has been proposed for IMSs data analysis. The first IMS represents the use of pure Artificial Neural Network system for boiler trip detection. All seven boiler trips under consideration have been detected by IMSs before or at the same time of the plant control system. The second IMS represents the use of Genetic Algorithms and Artificial Neural Networks as a hybrid intelligent system. A slightly lower root mean square error was observed in the second system which reveals that the hybrid intelligent system performed better than the pure neural network system. Also, the optimal selection of the most influencing variables performed successfully by the hybrid intelligent system.

  11. Development and Demonstration of a 25 Watt Thermophotovoltaic Power Source for a Hybrid Power System

    Science.gov (United States)

    Doyle, Edward; Shukla, Kailash; Metcalfe, Christopher

    2001-01-01

    The development of a propane-fueled, 25 W thermophotovoltaic (TPV) power source for use in a hybrid power system is described. The TPV power source uses a platinum emitting surface with an anti-reflective coating to radiate to gallium antimonide photocells, which converts the radiation to electric power. The development program started with the design and fabrication of an engineering prototype system. This was used as a component development vehicle to develop the technologies for the various components. A 25 W demonstration prototype was then designed and fabricated using the most advanced component approaches. The designs and test results from this development program are discussed.

  12. Thermoeconomic Analysis of Hybrid Power Plant Concepts for Geothermal Combined Heat and Power Generation

    OpenAIRE

    Florian Heberle; Dieter Brüggemann

    2014-01-01

    We present a thermo-economic analysis for a low-temperature Organic Rankine Cycle (ORC) in a combined heat and power generation (CHP) case. For the hybrid power plant, thermal energy input is provided by a geothermal resource coupled with the exhaust gases of a biogas engine. A comparison to alternative geothermal CHP concepts is performed by considering variable parameters like ORC working fluid, supply temperature of the heating network or geothermal water temperature. Second law efficiency...

  13. Evaluation of Hybrid Power Plants using Biomass, Photovoltaics and Steam Electrolysis for Hydrogen and Power Generation

    Science.gov (United States)

    Petrakopoulou, F.; Sanz, J.

    2014-12-01

    Steam electrolysis is a promising process of large-scale centralized hydrogen production, while it is also considered an excellent option for the efficient use of renewable solar and geothermal energy resources. This work studies the operation of an intermediate temperature steam electrolyzer (ITSE) and its incorporation into hybrid power plants that include biomass combustion and photovoltaic panels (PV). The plants generate both electricity and hydrogen. The reference -biomass- power plant and four variations of a hybrid biomass-PV incorporating the reference biomass plant and the ITSE are simulated and evaluated using exergetic analysis. The variations of the hybrid power plants are associated with (1) the air recirculation from the electrolyzer to the biomass power plant, (2) the elimination of the sweep gas of the electrolyzer, (3) the replacement of two electric heaters with gas/gas heat exchangers, and (4) the replacement two heat exchangers of the reference electrolyzer unit with one heat exchanger that uses steam from the biomass power plant. In all cases, 60% of the electricity required in the electrolyzer is covered by the biomass plant and 40% by the photovoltaic panels. When comparing the hybrid plants with the reference biomass power plant that has identical operation and structure as that incorporated in the hybrid plants, we observe an efficiency decrease that varies depending on the scenario. The efficiency decrease stems mainly from the low effectiveness of the photovoltaic panels (14.4%). When comparing the hybrid scenarios, we see that the elimination of the sweep gas decreases the power consumption due to the elimination of the compressor used to cover the pressure losses of the filter, the heat exchangers and the electrolyzer. Nevertheless, if the sweep gas is used to preheat the air entering the boiler of the biomass power plant, the efficiency of the plant increases. When replacing the electric heaters with gas-gas heat exchangers, the

  14. Hybrid-Circuit Module For Dc-To-Dc Power Converter

    Science.gov (United States)

    Vorperian, Vatche; Detwiler, Robert; Karmon, Dan

    1996-01-01

    Power hybrid module is general-purpose power-switching module providing flexibility in design and application. Complete dc-to-dc power converter constructed by adding input/output filters and feedback circuitry to module to suit specific application.

  15. POWER OPTIMIZED DATAPATH UNITS OF HYBRID EMBEDDED CORE ARCHITECTURE USING CLOCK GATING TECHNIQUE

    National Research Council Canada - National Science Library

    T.Subhashini; M.Kamaraju

    2015-01-01

    ...% of the total power dissipation. The main goal of this work is to implement a prototype power optimized datapath unit and ALU of Hybrid Embedded Controller Architecture targeted on to the FPGA chip and analyze the power consumption...

  16. Cost based reactive power participation for voltage control in multi units based isolated hybrid power system

    Directory of Open Access Journals (Sweden)

    Nitin Kumar Saxena

    2016-12-01

    Full Text Available Multi units of wind and diesel based generators in isolated hybrid power system have technical and operational advantages over single units system. They require dynamic reactive power compensation for fast recovery of voltage under load and input changes. In developing countries like India, investors’ prime concern is to provide continuous electricity at low rate while quality degradation can be permitted within pre defined acceptable range. The use of static compensator along with dynamic compensator may give cost effective reactive power participation for system. This paper presented pricing of reactive power compensation under steady state and transient conditions of system with fixed capacitor and STATCOM. The main contributions of the paper are; (i evaluating reactive power balance equation for generalized multi units of wind and diesel based isolated hybrid power system, (ii reactive power compensation using fixed capacitor and STATCOM in presence of composite load model, (ii fast recovery of voltage response using genetic algorithm based tuning of STATCOM controller, (iii evaluation of reactive power compensation cost for steady and dynamic conditions due to probabilistic change in load and/or input demand and (iv comparison of results with existing reference compensation method.

  17. Techno-economic analysis of stand-alone photovoltaic/wind/battery/hydrogen systems for very small-scale applications

    Directory of Open Access Journals (Sweden)

    Stojković Saša M.

    2016-01-01

    Full Text Available The paper presents the results of a technical and economic analysis of three stand-alone hybrid power systems based on renewable energy sources which supply a specific group of low-power consumers. This particular case includes measuring sensors and obstacle lights on a meteorological mast for wind measurements requiring an uninterrupted power supply in cold climate conditions. Although these low-power (100 W measuring sensors and obstacle lights use little energy, their energy consumption is not the same as the available solar energy obtained on a daily or seasonal basis. In the paper, complementarity of renewable energy sources was analysed, as well as one of short-term lead-acid battery-based storage and seasonal, hydrogen-based (electrolyser, H2 tank, and fuel cells storage. These relatively complex power systems were proposed earlier for high-power consumers only, while this study specifically highlights the role of the hydrogen system for supplying low-power consumers. The analysis employed a numerical simulation method using the HOMER software tool. The results of the analysis suggest that solar and wind-solar systems, which involve meteorological conditions as referred to in this paper, include a relatively large number of lead-acid batteries. Additionally, the analysis suggests that the use of hydrogen power systems for supplying low power-consumers is entirely justifiable, as it significantly reduces the number of batteries (two at minimum in this particular case. It was shown that the increase in costs induced by the hydrogen system is acceptable.

  18. Dynamic response evaluation of sensorless MPPT method for hybrid PV-DFIG wind turbine system

    Directory of Open Access Journals (Sweden)

    Danvu Nguyen

    2016-01-01

    Full Text Available This research proposes a sensorless Maximum Power Point Tracking (MPPT method for a hybrid Photovoltaic-Wind system, which consists of Photovoltaic (PV system and Doubly-Fed Induction Generator (DFIG Wind Turbine. In the hybrid system, the DC/DC converter output of the PV system is directly connected to the DC-link of DFIG’s back-to-back converter. Therefore, the PV inverter and its associated circuit can be removed in this structure. Typically, the PV power is monitored by using PV current sensor and PV voltage sensor for MPPT. In this paper, the powers of converters on grid side and rotor side of DFIG are used to estimate the PV power without the PV current sensor. That can efficiently reduce the cost of the hybrid system. The detailed analysis of the sensorless MPPT method, which includes derived equations and operation response, is also presented in this paper. In addition, an overview of PV-DFIG research in literature is stated to supply comprehensive knowledge of related research.

  19. Power Management of Hybrid Power Systems with Li-Fe Batteries and Supercapacitors for Mobile Robots

    Directory of Open Access Journals (Sweden)

    Guohui Wang

    2014-05-01

    Full Text Available This paper presents an energy management strategy of a Li-Fe battery and supercapacitor hybrid power system to provide both high power density and energy density for mobile robots with fluctuating workloads. A two-phase power-optimization approach is proposed to exploit the high power density of supercapacitors and the high energy density of Li-Fe batteries. With our strategy, large peak power can be provided for a short time period whenever needed, while low power can be provided for very long time. A set of experiments have been conducted. The experimental results show that our strategy can effectively improve the performance of mobile robots and extend the lifetime of batteries.

  20. Intelligent uninterruptible power supply system with back-up fuel cell/battery hybrid power source

    Science.gov (United States)

    Zhan, Yuedong; Guo, Youguang; Zhu, Jianguo; Wang, Hua

    2008-05-01

    This paper presents the development of an intelligent uninterruptible power supply (UPS) system with a hybrid power source that comprises a proton-exchange membrane fuel cell (PEMFC) and a battery. Attention is focused on the architecture of the UPS hybrid system and the data acquisition and control of the PEMFC. Specifically, the hybrid UPS system consists of a low-cost 60-cell 300 W PEMFC stack, a 3-cell lead-acid battery, an active power factor correction ac-dc rectifier, a half-bridge dc-ac inverter, a dc-dc converter, an ac-dc charger and their control units based on a digital signal processor TMS320F240, other integrated circuit chips, and a simple network management protocol adapter. Experimental tests and theoretical studies are conducted. First, the major parameters of the PEMFC are experimentally obtained and evaluated. Then an intelligent control strategy for the PEMFC stack is proposed and implemented. Finally, the performance of the hybrid UPS system is measured and analyzed.

  1. Hybrid Solar: A Review on Photovoltaic and Thermal Power Integration

    Directory of Open Access Journals (Sweden)

    T. T. Chow

    2012-01-01

    Full Text Available The market of solar thermal and photovoltaic electricity generation is growing rapidly. New ideas on hybrid solar technology evolve for a wide range of applications, such as in buildings, processing plants, and agriculture. In the building sector in particular, the limited building space for the accommodation of solar devices has driven a demand on the use of hybrid solar technology for the multigeneration of active power and/or passive solar devices. The importance is escalating with the worldwide trend on the development of low-carbon/zero-energy buildings. Hybrid photovoltaic/thermal (PVT collector systems had been studied theoretically, numerically, and experimentally in depth in the past decades. Together with alternative means, a range of innovative products and systems has been put forward. The final success of the integrative technologies relies on the coexistence of robust product design/construction and reliable system operation/maintenance in the long run to satisfy the user needs. This paper gives a broad review on the published academic works, with an emphasis placed on the research and development activities in the last decade.

  2. Modeling and simulation of a hybrid ship power system

    Science.gov (United States)

    Doktorcik, Christopher J.

    2011-12-01

    Optimizing the performance of naval ship power systems requires integrated design and coordination of the respective subsystems (sources, converters, and loads). A significant challenge in the system-level integration is solving the Power Management Control Problem (PMCP). The PMCP entails deciding on subsystem power usages for achieving a trade-off between the error in tracking a desired position/velocity profile, minimizing fuel consumption, and ensuring stable system operation, while at the same time meeting performance limitations of each subsystem. As such, the PMCP naturally arises at a supervisory level of a ship's operation. In this research, several critical steps toward the solution of the PMCP for surface ships have been undertaken. First, new behavioral models have been developed for gas turbine engines, wound rotor synchronous machines, DC super-capacitors, induction machines, and ship propulsion systems. Conventional models describe system inputs and outputs in terms of physical variables such as voltage, current, torque, and force. In contrast, the behavioral models developed herein express system inputs and outputs in terms of power whenever possible. Additionally, the models have been configured to form a hybrid system-level power model (HSPM) of a proposed ship electrical architecture. Lastly, several simulation studies have been completed to expose the capabilities and limitations of the HSPM.

  3. Power maximization for pyroelectric, piezoelectric, and hybrid energy harvesting

    Science.gov (United States)

    Shaheen, Murtadha A.

    The goal of this dissertation consists of improving the efficiency of energy harvesting using pyroelectric and piezoelectric materials in a system by the proper characterization of electrical parameters, widening frequency, and coupling of both effects with the appropriate parameters. A new simple stand-alone method of characterizing the impedance of a pyroelectric cell has been demonstrated. This method utilizes a Pyroelectric single pole low pass filter technique, PSLPF. Utilizing the properties of a PSLPF, where a known input voltage is applied and capacitance C p and resistance Rp can be calculated at a frequency of 1 mHz to 1 Hz. This method demonstrates that for pyroelectric materials the impedance depends on two major factors: average working temperature, and the heating rate. Design and implementation of a hybrid approach using multiple piezoelectric cantilevers is presented. This is done to achieve mechanical and electrical tuning, along with bandwidth widening. In addition, a hybrid tuning technique with an improved adjusting capacitor method was applied. An toroid inductor of 700 mH is shunted in to the load resistance and shunt capacitance. Results show an extended frequency range up to 12 resonance frequencies (300% improvement) with improved power up to 197%. Finally, a hybrid piezoelectric and pyroelectric system is designed and tested. Using a voltage doubler, circuit for rectifying and collecting pyroelectric and piezoelectric voltages individually is proposed. The investigation showed that the hybrid energy is possible using the voltage doubler circuit from two independent sources for pyroelectrictity and piezoelectricity due to marked differences of optimal performance.

  4. Dynamic Modeling and Simulation on a Hybrid Power System for Electric Vehicle Applications

    Directory of Open Access Journals (Sweden)

    Hong-Wen He

    2010-11-01

    Full Text Available Hybrid power systems, formed by combining high-energy-density batteries and high-power-density ultracapacitors in appropriate ways, provide high-performance and high-efficiency power systems for electric vehicle applications. This paper first establishes dynamic models for the ultracapacitor, the battery and a passive hybrid power system, and then based on the dynamic models a comparative simulation between a battery only power system and the proposed hybrid power system was done under the UDDS (Urban Dynamometer Driving Schedule. The simulation results showed that the hybrid power system could greatly optimize and improve the efficiency of the batteries and their dynamic current was also decreased due to the participation of the ultracapacitors, which would have a good influence on batteries’ cycle life. Finally, the parameter matching for the passive hybrid power system was studied by simulation and comparisons.

  5. Present situation and prospects of development of photovoltaic power generation technologies. Taiyoko hatsuden gijutsu kaihatsu no genjo to tenbo

    Energy Technology Data Exchange (ETDEWEB)

    Yoshimi, Tetsuo (Kyocera Corp., Kyoto, (Japan))

    1990-02-10

    Around 1975 when research and trial production of solar cells were started, the price per 1Wp solar cell was tens of thousand yen. Afterward with the technical progress, it was decreased to the 700 yen level and the production amount is constantly increasing. Based on the theme of New Energy and Industrial Technology Development Organization project, methane gas hybrid system which is the combination of photovoltaic power generation and gas engine power generation with methane fermentation of excreta of domestic animals of livestock breeders who are obliged to move to places far from cities and who have no commercial power sources, photovoltaic-small quantity hydraulic power generation hybrid which supplies lighting to buildings of regional public organizations with the combination of hydraulic power generation utilizing medium and small sized rivers in the neighborhood, photovoltaic-wind power generation hybrid, and photovoltaic power generation systems for villages of Indonesia which are not electrified yet and whose natural environment is quite different from that of Japan are being pushed forward. In the future, the price of the photovoltaic power generation system must be further lowered, and its development must be further pushed for ward as one of measures to cope with the problems of the global environment. 4 figs., 1 tab.

  6. Hybrid LC filter for power electronic drives. Theory and implementation

    Energy Technology Data Exchange (ETDEWEB)

    Dzhankhotov, V.

    2009-07-01

    Power electronic converter drives use, for the sake of high efficiency, pulse-width modulation that results in sequences of high-voltage high-frequency steep-edged pulses. Such a signal contains a set of high harmonics not required for control purposes. Harmonics cause reflections in the cable between the motor and the inverter leading to faster winding insulation ageing. Bearing failures and problems with electromagnetic compatibility may also result. Electrical du/dt filters provide an effective solution to problems caused by pulse-width modulation, thereby increasing the performance and service life of the electrical machines. It is shown that RLC filters effectively decrease the reflection phenomena in the cable. Improved (simple, but effective) solutions are found for both differential- and common-mode signals; these solutions use a galvanic connection between the RLC filter star point and the converter DC link. Foil chokes and film capacitors are among the most widely used components in high-power applications. In actual applications they can be placed in different parts of the cabinet. This fact complicates the arrangement of the cabinet and decreases the reliability of the system. In addition, the inductances of connection wires may prevent filtration at high frequencies. This thesis introduces a new hybrid LC filter that uses a natural capacitance between the turns of the foil choke based on integration of an auxiliary layer into it. The main idea of the hybrid LC filter results from the fact that both the foil choke and the film capacitors have the same roll structure. Moreover, the capacitance between the turns ('intra capacitance') of the foil inductors is the reason for the deterioration of their properties at high frequencies. It is shown that the proposed filter has a natural cancellation of the intra capacitance. A hybrid LC filter may contain two or more foil layers isolated from each other and coiled on a core. The core material can be

  7. Low-power hybrid wireless network for monitoring infant incubators.

    Science.gov (United States)

    Shin, D I; Shin, K H; Kim, I K; Park, K S; Lee, T S; Kim, S I; Lim, K S; Huh, S J

    2005-10-01

    We have created a pilot wireless network for the convenient monitoring of temperature and humidity of infant incubators. This system combines infrared and radio frequency (RF) communication in order to minimize the power consumption of slave devices, and we therefore call it a hybrid wireless network. The slave module installed in the infant incubator receives the calling signal from the host with an infrared receiver, and sends temperature and humidity data to the host with an RF transmitter. The power consumption of the host system is not critical, and hence it uses the maximum power of infrared transmission and continuously operating RF receiver. In our test implementation, we included four slave devices. The PC calls each slave device every second and then waits for 6 s, resulting in a total scan period of 10 s. Slave devices receive the calling signals and transmit three data values (temperature, moisture, and skin temperature); their power demand is 1 mW, and can run for about 1000 h on four AA-size nickel-hydride batteries.

  8. Sliding Mode Controller for Three-Phase Hybrid Active Power Filter with Photovoltaic Application

    OpenAIRE

    Blorfan, Ayman; Merckle, Jean; Flieller, Damien; Wira, Patrice; Sturtzer, Guy

    2012-01-01

    International audience; This paper presents a new three-phase hybrid active power filter configuration that interconnects a passive high-pass filter in parallel with an active power filter and a photovoltaic system. The proposed configuration can improves the filtering performance of the conventional active power filter, as well as simultaneously supply the power from the photovoltaic arrays to the load and utility. This paper will describe the proposed hybrid active power filter control usin...

  9. Power Management Optimization of an Experimental Fuel Cell/Battery/Supercapacitor Hybrid System

    OpenAIRE

    Farouk Odeim; Jürgen Roes; Angelika Heinzel

    2015-01-01

    In this paper, an experimental fuel cell/battery/supercapacitor hybrid system is investigated in terms of modeling and power management design and optimization. The power management strategy is designed based on the role that should be played by each component of the hybrid power source. The supercapacitor is responsible for the peak power demands. The battery assists the supercapacitor in fulfilling the transient power demand by controlling its state-of-energy, whereas the fuel cell system, ...

  10. high power facto high power factor high power factor hybrid rectifier ...

    African Journals Online (AJOL)

    eobe

    increase in the number of electrical loads that some kind of ... application, the rectifiers, particularly in Gr setting, are .... Copyright© Faculty of Engineering, sity of Nigeria ... PRINCIPLE OF THE PROPOSED HYBRID RECTIFIER. PRINCIPLE OF ...

  11. Control of a hybrid HVDC link to increase inter-regional power transfer

    DEFF Research Database (Denmark)

    Kotb, Omar; Ghandhari, Mehrdad; Eriksson, Robert

    2016-01-01

    This paper examines the application of a hybrid HVDC link in a two area power system with the purpose of increasing the inter-regional power transfer. A hybrid HVDC system combines both LCCs and VSCs, and hence it is capable of combining the benefits of both converter technologies, such as reduced...... cost and power losses due to the LCCs, and ability to connect to weak AC grids due to the VSCs. The mathematical model of the power system including the HVDC link is presented. The increase in inter-area power transfer is demonstrated and compared to the case when the hybrid HVDC link is not used....... Furthermore, the transient stability of the AC/DC power system was enhanced using auxiliary controllers for Power Oscillation Damping (POD). The results show the ability of the hybrid HVDC link to increase the unidirectional inter-area power transfer, while enhancing the transient stability of the power...

  12. Dynamic Power Management for Portable Hybrid Power-Supply Systems Utilizing Approximate Dynamic Programming

    Directory of Open Access Journals (Sweden)

    Jooyoung Park

    2015-05-01

    Full Text Available Recently, the optimization of power flows in portable hybrid power-supply systems (HPSSs has become an important issue with the advent of a variety of mobile systems and hybrid energy technologies. In this paper, a control strategy is considered for dynamically managing power flows in portable HPSSs employing batteries and supercapacitors. Our dynamic power management strategy utilizes the concept of approximate dynamic programming (ADP. ADP methods are important tools in the fields of stochastic control and machine learning, and the utilization of these tools for practical engineering problems is now an active and promising research field. We propose an ADP-based procedure based on optimization under constraints including the iterated Bellman inequalities, which can be solved by convex optimization carried out offline, to find the optimal power management rules for portable HPSSs. The effectiveness of the proposed procedure is tested through dynamic simulations for smartphone workload scenarios, and simulation results show that the proposed strategy can successfully cope with uncertain workload demands.

  13. Recent progress in battery models for hybrid wind power systems

    Energy Technology Data Exchange (ETDEWEB)

    Manwell, J.F.; McGowan, J.G.; Baring-Gould, I.; Stein, W. [Univ. of Massachusetts, Amherst, MA (United States)

    1995-12-31

    This paper summarizes the latest University of Massachusetts work on the analytical modeling and experimental testing of battery component models for hybrid power systems. An extension of the Kinetic Battery Model (KiBaM), developed at the University of Massachusetts is presented. The original model was based on a combination of phenomenological and physical considerations. As described in this paper, the modified KiBaM can now model the sharp increase in voltage near the end of charging, and the sharp drop in voltage when the battery is nearly empty. This model may readily be coupled with a DC load or charging source (such as a DC wind turbine or photovoltaic panels) to determine the corresponding DC bus voltage. For example, it is now an integral part of the DC bus section of the University of Massachusetts HYBRID simulation models. The paper describes the development of the extensions to the KiBaM model and the method of determining the constants from test data. On the experimental/applications side, it includes an illustration of how the constants are obtained from representative data (using a specially developed testing apparatus), and an example of how the model can be used.

  14. Adaptive Current Control Method for Hybrid Active Power Filter

    Science.gov (United States)

    Chau, Minh Thuyen

    2016-09-01

    This paper proposes an adaptive current control method for Hybrid Active Power Filter (HAPF). It consists of a fuzzy-neural controller, identification and prediction model and cost function. The fuzzy-neural controller parameters are adjusted according to the cost function minimum criteria. For this reason, the proposed control method has a capability on-line control clings to variation of the load harmonic currents. Compared to the single fuzzy logic control method, the proposed control method shows the advantages of better dynamic response, compensation error in steady-state is smaller, able to online control is better and harmonics cancelling is more effective. Simulation and experimental results have demonstrated the effectiveness of the proposed control method.

  15. Shape changing thin films powered by DNA hybridization

    Science.gov (United States)

    Shim, Tae Soup; Estephan, Zaki G.; Qian, Zhaoxia; Prosser, Jacob H.; Lee, Su Yeon; Chenoweth, David M.; Lee, Daeyeon; Park, So-Jung; Crocker, John C.

    2017-01-01

    Active materials that respond to physical and chemical stimuli can be used to build dynamic micromachines that lie at the interface between biological systems and engineered devices. In principle, the specific hybridization of DNA can be used to form a library of independent, chemically driven actuators for use in such microrobotic applications and could lead to device capabilities that are not possible with polymer- or metal-layer-based approaches. Here, we report shape changing films that are powered by DNA strand exchange reactions with two different domains that can respond to distinct chemical signals. The films are formed from DNA-grafted gold nanoparticles using a layer-by-layer deposition process. Films consisting of an active and a passive layer show rapid, reversible curling in response to stimulus DNA strands added to solution. Films consisting of two independently addressable active layers display a complex suite of repeatable transformations, involving eight mechanochemical states and incorporating self-righting behaviour.

  16. A Wind Power and Load Prediction Based Frequency Control Approach for Wind-Diesel-Battery Hybrid Power System

    OpenAIRE

    Chao Peng; Zhenzhen Zhang; Jia Wu

    2015-01-01

    A frequency control approach based on wind power and load power prediction information is proposed for wind-diesel-battery hybrid power system (WDBHPS). To maintain the frequency stability by wind power and diesel generation as much as possible, a fuzzy control theory based wind and diesel power control module is designed according to wind power and load prediction information. To compensate frequency fluctuation in real time and enhance system disturbance rejection ability, a battery energy ...

  17. A Review of Hybrid Renewable Energy Systems for Electric Power Generation

    Directory of Open Access Journals (Sweden)

    Md. Ibrahim

    2015-08-01

    Full Text Available Integration and combined utilization of renewable energy sources are becoming increasingly attractive. This paper is a review of hybrid renewable energy systems technologies for power generation, important issues and challenges in their design stage. Generation technology selection and unit sizing, System configurations and Energy management and control are discussed. Applications of hybrid energy systems, advantages of hybrid energy systems, issues and problems related to hybrid energy systems and an overview of energy storage technologies for renewable energy systems are presented. This paper also highlights the future trends of Hybrid energy systems, which represent a promising sustainable solution for power generation.

  18. Analysis of off-grid hybrid wind turbine/solar PV water pumping systems

    Science.gov (United States)

    While many remote water pumping systems exist (e.g. mechanical windmills, solar photovoltaic , wind-electric, diesel powered), very few combine both the wind and solar energy resources to possibly improve the reliability and the performance of the system. In this paper, off-grid wind turbine (WT) a...

  19. A Review of Hybrid Renewable Energy Systems for Electric Power Generation

    OpenAIRE

    Md. Ibrahim; Abul Khair

    2015-01-01

    Integration and combined utilization of renewable energy sources are becoming increasingly attractive. This paper is a review of hybrid renewable energy systems technologies for power generation, important issues and challenges in their design stage. Generation technology selection and unit sizing, System configurations and Energy management and control are discussed. Applications of hybrid energy systems, advantages of hybrid energy systems, issues and problems related to hybrid ...

  20. Intrinsic borohydride fuel cell/battery hybrid power sources

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Jian; Fang, Bin; Wang, Chunsheng; Currie, Kenneth [Center for Manufacturing Research, Department of Chemical Engineering, Tennessee Technological University, Cookeville, TN 38505 (United States)

    2006-10-27

    The electrochemical oxidation behaviors of NaBH{sub 4} on Zn, Zn-MH, and MH (metal-hydride) electrodes were investigated, and an intrinsic direct borohydride fuel cell (DBFC)/battery hybrid power source using MH (or Zn-MH) as the anode and MnO{sub 2} as the cathode was tested. Borohydride cannot be effectively oxidized on Zn electrodes at the Zn oxidation potential because of the poor electrocatalytic ability of Zn for borohydride oxidation and the high overpotential, even though borohydride has the same oxidation potential of Zn in an alkaline solution. The borohydride can be electrochemically oxidized on Ni and MH electrodes through a 4e reaction at a high overpotential. Simply adding borohydride into an alkaline electrolyte of a Zn/air or MH/air battery can greatly increase the capacity, while an intrinsic DBFC/MH(or Zn)-MnO{sub 2} battery can deliver a higher peak power than regular DBFCs. (author)

  1. Hybrid aqueous capacitors with improved energy/power performance

    Directory of Open Access Journals (Sweden)

    Jakub Menzel

    2015-12-01

    Full Text Available This work reports on a high-voltage, hybrid capacitor involving two separate redox reactions. Aqueous solutions of Mg(NO32 and KI have been used for negative and positive electrode, respectively. Adjusting pH=2 for electrode (+ with KI solution and modifying Mg(NO32 solution to pH=9 for negative side play a crucial role for a stable long-term operation of capacitor at enhanced voltage. A benefit from such a construction is a pseudocapacitive contribution from hydrogen sorption reaction on the negative electrode and high iodine/iodide activity on the positive electrode, enhancing the energy with no remarkable impact on the power profile. Proposed solution allows a high voltage (1.8 V to be reached and thereby high power and energy performance (~20 W h/kg at 1 kW/kg to be obtained. High long-term stability has been confirmed by floating and galvanostatic tests.

  2. Study of hybrid power system potential to power agricultural water pump in mountain area

    Energy Technology Data Exchange (ETDEWEB)

    Syuhada, Ahmad, E-mail: syuhada-mech@yahoo.com; Mubarak, Amir Zaki, E-mail: amir-zaki-mubarak@yahoo.com; Maulana, M. Ilham, E-mail: mil2ana@yahoo.com [Mechanical Engineering Department, Engineering Faculty, Syiah Kuala University Jl. Syech Abdul Rauf No.7 Darussalam Banda Aceh 23111 (Indonesia)

    2016-03-29

    As industry and Indonesian economy grow fast, there are a lot of agricultural land has changed into housing and industrial land. This causes the agricultural land moves to mountain area. In mountainous agricultural area, farmers use the water resources of small rivers in the groove of the mountain to irrigate the farmland. Farmers use their power to lift up water from the river to their land which causes inefectivity in the work of the farmers. Farmers who have capital utilize pump to raise water to their land. The only way to use pump in mountain area is by using fuel energy as there is no electricity, and the fuel price in mountain area is very expensive. Based on those reasons it is wise to consider the exploration of renewable energy available in the area such as solar energy, wind energy and hybrid energy. This study analyses the potential of the application of hybrid power plant, which is the combination of solar and wind energy, to power agricultural pump. In this research, the data of wind speed and solar radiation are collected from the measurement of BMKG SMPK Plus Sare. Related to the solar energy, the photovoltaic output power calculation is 193 W with duration of irradiation of 5 hours/day. While for the wind energy, the output power of the wind turbine is 459.84 W with blade diameter of 3 m and blow duration of 7 hours/day. The power of the pump is 558 W with 8 hours of usage, and the water capacity is 2.520 liters/hour for farmland with the area of 15 ha. Based on the analysis result, the designed system will generate electricity of 3.210 kW/year with initial investment of US$ 14,938.

  3. Study of hybrid power system potential to power agricultural water pump in mountain area

    Science.gov (United States)

    Syuhada, Ahmad; Mubarak, Amir Zaki; Maulana, M. Ilham

    2016-03-01

    As industry and Indonesian economy grow fast, there are a lot of agricultural land has changed into housing and industrial land. This causes the agricultural land moves to mountain area. In mountainous agricultural area, farmers use the water resources of small rivers in the groove of the mountain to irrigate the farmland. Farmers use their power to lift up water from the river to their land which causes inefectivity in the work of the farmers. Farmers who have capital utilize pump to raise water to their land. The only way to use pump in mountain area is by using fuel energy as there is no electricity, and the fuel price in mountain area is very expensive. Based on those reasons it is wise to consider the exploration of renewable energy available in the area such as solar energy, wind energy and hybrid energy. This study analyses the potential of the application of hybrid power plant, which is the combination of solar and wind energy, to power agricultural pump. In this research, the data of wind speed and solar radiation are collected from the measurement of BMKG SMPK Plus Sare. Related to the solar energy, the photovoltaic output power calculation is 193 W with duration of irradiation of 5 hours/day. While for the wind energy, the output power of the wind turbine is 459.84 W with blade diameter of 3 m and blow duration of 7 hours/day. The power of the pump is 558 W with 8 hours of usage, and the water capacity is 2.520 liters/hour for farmland with the area of 15 ha. Based on the analysis result, the designed system will generate electricity of 3.210 kW/year with initial investment of US 14,938.

  4. Outage Performance of Hybrid FSO/RF System with Low-Complexity Power Adaptation

    KAUST Repository

    Rakia, Tamer

    2016-02-26

    Hybrid free-space optical (FSO) / radio-frequency (RF) systems have emerged as a promising solution for high data- rate wireless communication systems. We consider truncated channel inversion based power adaptation strategy for coherent and non- coherent hybrid FSO/RF systems, employing an adaptive combining scheme. Specifically, we activate the RF link along with the FSO link when FSO link quality is unacceptable, and adaptively set RF transmission power to ensure constant combined signal-to-noise ratio at receiver terminal. Analytical expressions for the outage probability of the hybrid system with and without power adaptation are derived. Numerical examples show that, the hybrid FSO/RF systems with power adaptation achieve considerable outage performance improvement over conventional hybrid FSO/RF systems without power adaptation. © 2015 IEEE.

  5. New hybrid active power filter for harmonic current suppression and reactive power compensation

    Science.gov (United States)

    Biricik, Samet; Cemal Ozerdem, Ozgur; Redif, Soydan; Sezai Dincer, Mustafa

    2016-08-01

    In the case of undistorted and balanced grid voltages, low ratio shunt active power filters (APFs) can give unity power factors and achieve current harmonic cancellation. However, this is not possible when source voltages are distorted and unbalanced. In this study, the cost-effective hybrid active power filter (HAPF) topology for satisfying the requirements of harmonic current suppression and non-active power compensation for industry is presented. An effective strategy is developed to observe the effect of the placement of power capacitors and LC filters with the shunt APF. A new method for alleviating the negative effects of a nonideal grid voltage is proposed that uses a self-tuning filter algorithm with instantaneous reactive power theory. The real-time control of the studied system was achieved with a field-programmable gate array (FPGA) architecture, which was developed using the OPAL-RT system. The performance result of the proposed HAPF system is tested and presented under nonideal supply voltage conditions.

  6. Solid Oxide Fuel Cell/Turbine Hybrid Power System for Advanced Aero-propulsion and Power Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Solid oxide fuel cell (SOFC)/ gas turbine hybrid power systems (HPSs) have been recognized by federal agencies and other entities as having the potential to operate...

  7. Critical Resources for Emerging Battery Technologies for Hybrid and Electric Vehicles. Proceedings of the International Conference “ISWA World Solid Waste Congress”, 17th - 19th September 2012, Florence, Italy

    DEFF Research Database (Denmark)

    Habib, Komal; Nyander, Nils Christian; Wenzel, Henrik

    2012-01-01

    such as photovoltaics, wind turbines, electric and hybrid cars are, however, in turn dependent on other non- renewable resources such as metals which may become scarce in the future. The concept of ‘critical resources’ is in this context is an expression of how limited or constrained the supply of a resource...

  8. Robust PI-based Frequency Control of Isolated Wind-Diesel Power System with Coordinated Governor, Pitch and Battery Controller

    Science.gov (United States)

    Nandar, Cuk Supriyadi Ali; Hashiguchi, Takuhei; Goda, Tadahiro

    A penetration of renewable energy sources such as photovoltaic, wind power etc to prevent global warming is become increasing highly. However, a random unpredictable wind power output may cause frequency fluctuation on isolated hybrid wind-diesel power system. This paper proposes design of coordinated control of governor, pitch and battery to stabilize frequency fluctuation in isolated wind-diesel power system. A well coordinated control between governor, pitch and battery controller are able to improve a performance and also minimize an interaction between the controllers. The structure of the proposed controllers are the first-order PI controller. They are simple and easy to implement in power system utilities. The robustness of the proposed PI controllers are guaranteed by applying an inverse additive perturbation to represent possible unstructured uncertainties in the power system such as variation of system parameters, generating and loading conditions etc. The proposed PI control parameters are optimized and achieved by a genetic algorithm (GA). Simulation studies have been done to show the control effect and robustness of the proposed PI controller in isolated hybrid wind-diesel power system against various disturbances and system uncertainties.

  9. Demonstrative study for the wind and solar hybrid power system. 2; Furyoku taiyoko hybrid hatsuden system ni kansuru jissho kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, Y.; Sakuma, H.; Ushiyama, I. [Ashikaga Institute of Technology, Tochigi (Japan)

    1996-10-27

    In order to verify the complementary relationship between wind and solar energy, the long-term field test of the hybrid power system was conducted at the natural energy square of Ashikaga Institute of Technology. The solar cell blade windmill composed of a Savonius windmill and flexible solar cells applied to swept buckets was also prepared. As a result, the wind power generation was promising mainly in the winter period including the late fall and early spring, while solar one was stable all the year through although it was slightly poor in winter. Stable power generation was thus achieved by combining wind energy with solar energy. As the whole data of other wind and solar power generation systems at the square were analyzed for every month, the same conclusion as the solar cell blade windmill was obtained as follows: the wind power generation in Ashikaga area is promising in Nov.-March from the field test result for 16 months, solar power generation is stable all the year through, the hybrid power system is effective in Nov.-April, and the solar cell blade windmill is equivalent to the hybrid power system. 3 refs., 5 figs.

  10. Hybrid propulsion with highest electric power density for the ML 450 BlueHYBRID; Hybridantrieb mit hoechster elektrischen Leistungsdichte fuer den ML 450 BlueHYBRID

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, Michael; Armstrong, Neil; Schenk, Juergen; Nietfeld, Franz; Inderka, Robert [Daimler AG, Stuttgart (Germany)

    2009-07-01

    The ML 450 BlueHYBRID is an elementary milestone in the strategy to the sustainable mobility at Daimler AG (Stuttgart, Federal Republic of Germany). This hybrid system based on the current M-class and is equipped with the innovative Two-Mode-Hybrid-System AHS-C with two high speed electrical engines. The entire propulsion system, the battery and power electronics and the strategy of operation particularly developed for this vehicle integrally provide for a significant reduction of consumption and emission. At the same time, the comfort of the total vehicle increases. In the ML 450 BlueHYBRID, a high volt battery on basis of nickel metal hydride is used. This battery consists of an extremely compact building method and enables an optimal packaging in the vehicle. For the first time, the cooling is performed with a liquid. This enables a stable operation in all situations. For the first time, the cooling takes place with a liquid and enables a stable enterprise in all situations. In connection with the AHS-C Two-Mode-Hybrid system, the battery system enables all hybrid-specific operation conditions such as a purely electrical tour, engine start stop, recupation, boosting. The ML 450 BlueHYBRID serially is produced in Tuscaloose (Alabama, USA). The manufacturing of the hybrid vehicle completely is integrated in the operation of work and is based on the existing serial production plants with hybrid-specific supplements and adjustments in assembly stations.

  11. A New Control Method to Mitigate Power Fluctuations for Grid Integrated PV/Wind Hybrid Power System Using Ultracapacitors

    Science.gov (United States)

    Jayalakshmi, N. S.; Gaonkar, D. N.

    2016-08-01

    The output power obtained from solar-wind hybrid system fluctuates with changes in weather conditions. These power fluctuations cause adverse effects on the voltage, frequency and transient stability of the utility grid. In this paper, a control method is presented for power smoothing of grid integrated PV/wind hybrid system using ultracapacitors in a DC coupled structure. The power fluctuations of hybrid system are mitigated and smoothed power is supplied to the utility grid. In this work both photovoltaic (PV) panels and the wind generator are controlled to operate at their maximum power point. The grid side inverter control strategy presented in this paper maintains DC link voltage constant while injecting power to the grid at unity power factor considering different operating conditions. Actual solar irradiation and wind speed data are used in this study to evaluate the performance of the developed system using MATLAB/Simulink software. The simulation results show that output power fluctuations of solar-wind hybrid system can be significantly mitigated using the ultracapacitor based storage system.

  12. A New Hybrid Power Configuration Used In HEV And Development of Its Driving BLDC

    Directory of Open Access Journals (Sweden)

    Yanliang Xu

    2013-07-01

    Full Text Available Hybrid electric vehicle (HEV that has the advantages of high performance, high fuel efficiency, low emissions, and long operating range is focused on nowadays. A new hybrid power configuration used in HEV is presented with different control strategies and HEV performances when equipping different weight of fuel power and battery one. In order to realize the new hybrid power configuration especially in the refitted HEV, fractional-slot concentrated-wingding BLDC with higher rated spinning speed is given and the prototyped one is developed and fabricated which satisfy successfully the requirements of high performance and demission restriction for the refitted HEV.

  13. Hybrid centralized-distributed power conditioning system for thermoelectric generator with high energy efficiency

    DEFF Research Database (Denmark)

    Wu, Hongfei; Sun, Kai; Chen, Min;

    2013-01-01

    The unbalanced temperature distribution influences the power output of thermoelectric generator (TEG) system, which leads to mismatch power among TEG modules. This mismatch power degrades the energy efficiency of TEG systems based on the series-connected TEG modules. A hybrid centralized-distribu......The unbalanced temperature distribution influences the power output of thermoelectric generator (TEG) system, which leads to mismatch power among TEG modules. This mismatch power degrades the energy efficiency of TEG systems based on the series-connected TEG modules. A hybrid centralized...... the proposed system, which benefits for implementing high MPPT efficiency and high conversion efficiency simultaneously. A hybrid MPPT control strategy is proposed for this HCD power conditioning system. The characteristics, circuit implementation and operation principles of the proposed system are presented...

  14. A Numerical Approach for Hybrid Simulation of Power System Dynamics Considering Extreme Icing Events

    DEFF Research Database (Denmark)

    Chen, Lizheng; Zhang, Hengxu; Wu, Qiuwei

    2017-01-01

    The global climate change leads to more extreme meteorological conditions such as icing weather, which have caused great losses to power systems. Comprehensive simulation tools are required to enhance the capability of power system risk assessment under extreme weather conditions. A hybrid...... numerical simulation scheme integrating icing weather events with power system dynamics is proposed to extend power system numerical simulation. A technique is developed to efficiently simulate the interaction of slow dynamics of weather events and fast dynamics of power systems. An extended package for PSS....../E enabling hybrid simulation of icing event and power system disturbance is developed, based on which a hybrid simulation platform is established. Numerical studies show that the functionality of power system simulation is greatly extended by taking into account the icing weather events....

  15. Site-specific analysis of hybrid geothermal/fossil power plants

    Energy Technology Data Exchange (ETDEWEB)

    1977-06-01

    A preliminary economic analysis of a hybrid geothermal/coal power plant has been completed for four geothermal Resource areas: Roosevelt Hot Springs, Coso Hot Springs, East Mesa and Long Valley. A hybrid plant would be economically viable at Roosevelt Hot Springs and somewhat less so at Coso Hot Springs. East Mesa and Long Valley show no economic promise. A well-designed hybrid plant could use geothermal energy for boiler feedwater heating, auxiliary power, auxiliary heating, and cooling water. Construction and operation of a hybrid plant at either Roosevelt Hot Springs or Coso Hot Springs is recommended. Brown University provided the theoretical basis for the hybrid study. A modified version of the Lawrence Berkeley Livermore GEOTHM Program is the major analytical tool used in the analysis. The Intermountain Power Project is the reference all coal-fired plant. Costing methods followed recommendations issued by the Energy research and Development Administration.

  16. A New Starting Method of the Hybrid Power Filter for Wind Power Generation Systems with Soft Starter

    Science.gov (United States)

    Yamada, Hiroaki; Hiraki, Eiji; Tanaka, Toshihiko

    This paper proposes a new method of starting the hybrid power filter for wind power generation systems with soft starter. In the proposed method, an active filter of the hybrid power filter behaves a resistor for the source current under the starting condition. Thus the inrush phenomena of the passive filter are perfectly suppressed. The basic principle of the proposed starting method is discussed, and then confirmed by digital computer simulation using PSCAD/EMTDC. Simulation results demonstrate that the proposed starting method can overcome the inrush currents for the passive filter, building up the dc voltage of the active filter.

  17. Modular Power System Configured with Standard Product Hybrid DC-DC Converters Project

    Data.gov (United States)

    National Aeronautics and Space Administration — VPT proposes an innovative concept whereby complex NASA space power electronic systems can be configured using a small number of qualified hybrid DC-DC converter and...

  18. Power Adaptation Based on Truncated Channel Inversion for Hybrid FSO/RF Transmission With Adaptive Combining

    KAUST Repository

    Rakia, Tamer

    2015-07-23

    Hybrid free-space optical (FSO)/radio-frequency (RF) systems have emerged as a promising solution for high-data-rate wireless communications. In this paper, we consider power adaptation strategies based on truncated channel inversion for the hybrid FSO/RF system employing adaptive combining. Specifically, we adaptively set the RF link transmission power when FSO link quality is unacceptable to ensure constant combined signal-to-noise ratio (SNR) at the receiver. Two adaptation strategies are proposed. One strategy depends on the received RF SNR, whereas the other one depends on the combined SNR of both links. Analytical expressions for the outage probability of the hybrid system with and without power adaptation are obtained. Numerical examples show that the hybrid FSO/RF system with power adaptation achieves a considerable outage performance improvement over the conventional system.

  19. NEURAL NETWORKS CONTROL OF THE HYBRID POWER UNIT BASED ON THE METHOD OF ADAPTIVE CRITICS

    Directory of Open Access Journals (Sweden)

    S. Serikov

    2012-01-01

    Full Text Available The formal statement of the optimization problem of hybrid vehicle power unit control is given. Its solving by neural networks method application on the basis of adaptive critic is considered.

  20. Energy Optimization for a Weak Hybrid Power System of an Automobile Exhaust Thermoelectric Generator

    Science.gov (United States)

    Fang, Wei; Quan, Shuhai; Xie, Changjun; Tang, Xinfeng; Ran, Bin; Jiao, Yatian

    2017-07-01

    An integrated starter generator (ISG)-type hybrid electric vehicle (HEV) scheme is proposed based on the automobile exhaust thermoelectric generator (AETEG). An eddy current dynamometer is used to simulate the vehicle's dynamic cycle. A weak ISG hybrid bench test system is constructed to test the 48 V output from the power supply system, which is based on engine exhaust-based heat power generation. The thermoelectric power generation-based system must ultimately be tested when integrated into the ISG weak hybrid mixed power system. The test process is divided into two steps: comprehensive simulation and vehicle-based testing. The system's dynamic process is simulated for both conventional and thermoelectric powers, and the dynamic running process comprises four stages: starting, acceleration, cruising and braking. The quantity of fuel available and battery pack energy, which are used as target vehicle energy functions for comparison with conventional systems, are simplified into a single energy target function, and the battery pack's output current is used as the control variable in the thermoelectric hybrid energy optimization model. The system's optimal battery pack output current function is resolved when its dynamic operating process is considered as part of the hybrid thermoelectric power generation system. In the experiments, the system bench is tested using conventional power and hybrid thermoelectric power for the four dynamic operation stages. The optimal battery pack curve is calculated by functional analysis. In the vehicle, a power control unit is used to control the battery pack's output current and minimize energy consumption. Data analysis shows that the fuel economy of the hybrid power system under European Driving Cycle conditions is improved by 14.7% when compared with conventional systems.

  1. Hybrid Model for Cascading Outage in a Power System: A Numerical Study

    OpenAIRE

    Susuki, Yoshihiko; Takatsuji, Yu; Hikihara, Takashi

    2009-01-01

    Analysis of cascading outages in power systems is important for understanding why large blackouts emerge and how to prevent them. Cascading outages are complex dynamics of power systems, and one cause of them is the interaction between swing dynamics of synchronous machines and protection operation of relays and circuit breakers. This paper uses hybrid dynamical systems as a mathematical model for cascading outages caused by the interaction. Hybrid dynamical systems can combine families of fl...

  2. A review and design of power electronics converters for fuel cell hybrid system applications

    DEFF Research Database (Denmark)

    Zhang, Zhe; Pittini, Riccardo; Andersen, Michael A. E.

    2012-01-01

    This paper presents an overview of most promising power electronics topologies for a fuel cell hybrid power conversion system which can be utilized in many applications such as hybrid electrical vehicles (HEV), distributed generations (DG) and uninterruptible-power-supply (UPS) systems. Then......, a multiple-input power conversion system including a decoupled dual-input converter and a three-phase neutral-point-clamped (NPC) inverter is proposed. The system can operate in both stand-alone and grid-connected modes. Simulation and experimental results are provided to show the feasibility of the proposed...

  3. Review and Comparison of Power Management Approaches for Hybrid Vehicles with Focus on Hydraulic Drives

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Karbaschian

    2014-05-01

    Full Text Available The main advantage of hybrid powertrains is based on the efficient transfer of power and torque from power sources to the powertrain as well as recapturing of reversible energies without effecting the vehicle performance. The benefits of hybrid hydraulic powertrains can be better utilized with an appropriate power management. In this paper, different types of power management algorithms like off-line and on-line methods are briefly reviewed and classified. Finally, the algorithms are evaluated and compared. Therefore, different related criteria are evaluated and applied.

  4. Application of Hybrid Optimization-Expert System for Optimal Power Management on Board Space Power Station

    Science.gov (United States)

    Momoh, James; Chattopadhyay, Deb; Basheer, Omar Ali AL

    1996-01-01

    The space power system has two sources of energy: photo-voltaic blankets and batteries. The optimal power management problem on-board has two broad operations: off-line power scheduling to determine the load allocation schedule of the next several hours based on the forecast of load and solar power availability. The nature of this study puts less emphasis on speed requirement for computation and more importance on the optimality of the solution. The second category problem, on-line power rescheduling, is needed in the event of occurrence of a contingency to optimally reschedule the loads to minimize the 'unused' or 'wasted' energy while keeping the priority on certain type of load and minimum disturbance of the original optimal schedule determined in the first-stage off-line study. The computational performance of the on-line 'rescheduler' is an important criterion and plays a critical role in the selection of the appropriate tool. The Howard University Center for Energy Systems and Control has developed a hybrid optimization-expert systems based power management program. The pre-scheduler has been developed using a non-linear multi-objective optimization technique called the Outer Approximation method and implemented using the General Algebraic Modeling System (GAMS). The optimization model has the capability of dealing with multiple conflicting objectives viz. maximizing energy utilization, minimizing the variation of load over a day, etc. and incorporates several complex interaction between the loads in a space system. The rescheduling is performed using an expert system developed in PROLOG which utilizes a rule-base for reallocation of the loads in an emergency condition viz. shortage of power due to solar array failure, increase of base load, addition of new activity, repetition of old activity etc. Both the modules handle decision making on battery charging and discharging and allocation of loads over a time-horizon of a day divided into intervals of 10

  5. Hybrid centralized-distributed power conditioning system for thermoelectric generator with high energy efficiency

    DEFF Research Database (Denmark)

    Wu, Hongfei; Sun, Kai; Chen, Min

    2013-01-01

    the proposed system, which benefits for implementing high MPPT efficiency and high conversion efficiency simultaneously. A hybrid MPPT control strategy is proposed for this HCD power conditioning system. The characteristics, circuit implementation and operation principles of the proposed system are presented......-distributed (HCD) power conditioning system for TEG and its control strategy are proposed in this paper. The HCD power conditioning system is composed by a centralized power conversion stage and multiple distributed power conversion stages. Most of the power is processed by the centralized power conversion stage...

  6. Model predictive control for power fluctuation supression in hybrid wind/PV/battery systems

    DEFF Research Database (Denmark)

    You, Shi; Liu, Zongyu; Zong, Yi

    2015-01-01

    predictive control (MPC)-based algorithm for battery management in a hybrid wind/PV/battery system to suppress the short-term power fluctuation on the ‘minute’ scale. A case study with data collected from a practical hybrid system setup is used to demonstrate the effectiveness of the proposed algorithm......A hybrid energy system, the combination of wind turbines, PV panels and battery storage with effective control mechanism, represents a promising solution to the power fluctuation problem when integrating renewable energy resources (RES) into conventional power systems. This paper proposes a model...... together with a Monte Carlo simulation-based sensitivity analysis. In addition to illustrating the complementarity between the fluctuations of wind power and PV power, the results prove the proposed MPC algorithm is effective in fluctuation suppression but sensitive to factors such as forecast accuracy...

  7. Control Strategy Based on Wavelet Transform and Neural Network for Hybrid Power System

    Directory of Open Access Journals (Sweden)

    Y. D. Song

    2013-01-01

    Full Text Available This paper deals with an energy management of a hybrid power generation system. The proposed control strategy for the energy management is based on the combination of wavelet transform and neural network arithmetic. The hybrid system in this paper consists of an emulated wind turbine generator, PV panels, DC and AC loads, lithium ion battery, and super capacitor, which are all connected on a DC bus with unified DC voltage. The control strategy is responsible for compensating the difference between the generated power from the wind and solar generators and the demanded power by the loads. Wavelet transform decomposes the power difference into smoothed component and fast fluctuated component. In consideration of battery protection, the neural network is introduced to calculate the reference power of battery. Super capacitor (SC is controlled to regulate the DC bus voltage. The model of the hybrid system is developed in detail under Matlab/Simulink software environment.

  8. Hybrid Model for Cascading Outage in a Power System: A Numerical Study

    Science.gov (United States)

    Susuki, Yoshihiko; Takatsuji, Yu; Hikihara, Takashi

    Analysis of cascading outages in power systems is important for understanding why large blackouts emerge and how to prevent them. Cascading outages are complex dynamics of power systems, and one cause of them is the interaction between swing dynamics of synchronous machines and protection operation of relays and circuit breakers. This paper uses hybrid dynamical systems as a mathematical model for cascading outages caused by the interaction. Hybrid dynamical systems can combine families of flows describing swing dynamics with switching rules that are based on protection operation. This paper refers to data on a cascading outage in the September 2003 blackout in Italy and shows a hybrid dynamical system by which propagation of outages reproduced is consistent with the data. This result suggests that hybrid dynamical systems can provide an effective model for the analysis of cascading outages in power systems.

  9. Fuzzy Controller for a Voltage-Regulated Solar-Powered MPPT System for Hybrid Power System Applications

    Directory of Open Access Journals (Sweden)

    Jaw-Kuen Shiau

    2015-04-01

    Full Text Available This paper presents the design of a fuzzy-logic-based voltage-regulated solar power maximum power point tracking (MPPT system for applications involving hybrid power systems. The system contains a solar power system and battery as the primary and secondary power sources, respectively. The solar system alone supplies power to the electric motor and maintains the output voltage at a predetermined level when it has sufficient power. When the solar power is insufficient, the solar system is operated at its maximum power point (MPP and the battery is engaged to compensate for the insufficiency. First, a variant of the incremental conductance MPP condition was established. Under the MPP condition, the voltage-regulated MPPT system was formulated as a feedback control system, where the MPP condition and voltage regulation requirements were used as the system inputs. Next, a fuzzy controller was developed to perform the voltage-regulated MPPT function for the hybrid power system. A simulation model based on Matrix laboratory (MATLAB/SIMULINK (a block diagram environment for multi-domain simulation and model-based design and a piecewise linear electric circuit simulation (PLECS tool for controlling the dc motor velocity was developed to verify the voltage-regulated solar power MPPT system.

  10. Use of a Geothermal-Solar Hybrid Power Plant to Mitigate Declines in Geothermal Resource Productivity

    Energy Technology Data Exchange (ETDEWEB)

    Dan Wendt; Greg Mines

    2014-09-01

    Many, if not all, geothermal resources are subject to decreasing productivity manifested in the form of decreasing brine temperature, flow rate, or both during the life span of the associated power generation project. The impacts of resource productivity decline on power plant performance can be significant; a reduction in heat input to a power plant not only decreases the thermal energy available for conversion to electrical power, but also adversely impacts the power plant conversion efficiency. The reduction in power generation is directly correlated to a reduction in revenues from power sales. Further, projects with Power Purchase Agreement (PPA) contracts in place may be subject to significant economic penalties if power generation falls below the default level specified. A potential solution to restoring the performance of a power plant operating from a declining productivity geothermal resource involves the use of solar thermal energy to restore the thermal input to the geothermal power plant. There are numerous technical merits associated with a renewable geothermal-solar hybrid plant in which the two heat sources share a common power block. The geo-solar hybrid plant could provide a better match to typical electrical power demand profiles than a stand-alone geothermal plant. The hybrid plant could also eliminate the stand-alone concentrated solar power plant thermal storage requirement for operation during times of low or no solar insolation. This paper identifies hybrid plant configurations and economic conditions for which solar thermal retrofit of a geothermal power plant could improve project economics. The net present value of the concentrated solar thermal retrofit of an air-cooled binary geothermal plant is presented as functions of both solar collector array cost and electricity sales price.

  11. Hybrid Cooling Systems for Low-Temperature Geothermal Power Production

    Energy Technology Data Exchange (ETDEWEB)

    Ashwood, A.; Bharathan, D.

    2011-03-01

    This paper describes the identification and evaluation of methods by which the net power output of an air-cooled geothermal power plant can be enhanced during hot ambient conditions with a minimal amount of water use.

  12. Optimizing a Hybrid Energy Storage System for a Virtual Power Plant for Improved Wind Power Generation: A Case Study for Denmark

    DEFF Research Database (Denmark)

    Braun, Philipp; Swierczynski, Maciej Jozef; Diosi, Robert

    2011-01-01

    This paper describes one approach to find two optimum energy storages (ESs) to build a hybrid system which is part of a virtual power plant. Here it means the combination of the hybrid energy storage system and wind power plant (WPP). The discussed approach is applied in a case study on the power...

  13. OPERATION & CONTROL OF SMART GRID CONNECTED PV- FC HYBRID POWER SYSTEMD.

    Directory of Open Access Journals (Sweden)

    Saritha(M tech

    2014-08-01

    Full Text Available This paper presents a method to operate and control a grid connected hybrid power system. The hybrid system composed of a Photovoltaic (PV array and a Proton exchange membrane fuel cell (PEMFC is considered. The PV array normally uses a maximum power point tracking (MPPT technique to continuously deliver the highest power to the load when variations in irradiation and temperature occur, which make it become an uncontrollable source. In coordination with PEMFC, the hybrid system output power becomes controllable. Two operation modes, the unit-power control (UPC mode and the feeder-flow control (FFC mode, can be applied to the hybrid system. The coordination of two control modes, the coordination of the PV array and the PEMFC in the hybrid system, and the determination of reference parameters are presented. The proposed operating strategy with a flexible operation mode change always operates the PV array at maximum output power and the PEMFC in its high efficiency performance band, thus improving the performance of system operation, enhancing system stability, and decreasing the number of operating mode changes

  14. Analysis of the Hybrid Power System for High-Altitude Unmanned Aircraft

    Directory of Open Access Journals (Sweden)

    Kangwen Sun

    2015-01-01

    Full Text Available The application of single solar array on high-altitude unmanned aircraft will waste energy because of its low conversion efficiency. Furthermore, since its energy utilization is limited, the surface temperature of solar array will rise to 70°C due to the waste solar energy, thus reducing the electrical performance of the solar array. In order to reuse the energy converted into heat by solar array, a hybrid power system is presented in this paper. In the hybrid power system, a new electricity-generating method is adopted to spread the photovoltaic cell on the wing surface and arrange photothermal power in the wing box section. Because the temperature on the back of photovoltaic cell is high, it can be used as the high-temperature heat source. The lower wing surface can be a low-temperature cold source. A high-altitude unmanned aircraft was used to analyze the performances of pure solar-powered aircraft and hybrid powered aircraft. The analysis result showed that the hybrid system could reduce the area of wing by 19% and that high-altitude unmanned aircraft with a 35 m or less wingspan could raise the utilization rate of solar energy per unit area after adopting the hybrid power system.

  15. Generator maintenance scheduling in power systems using metaheuristic-based hybrid approaches

    Energy Technology Data Exchange (ETDEWEB)

    Dahal, Keshav P. [School of Informatics, University of Bradford, Bradford (United Kingdom); Chakpitak, Nopasit [College of Arts, Media and Technology, Chiang Mai University, Chiang Mai (Thailand)

    2007-05-15

    The effective maintenance scheduling of power system generators is very important for the economical and reliable operation of a power system. This represents a tough scheduling problem which continues to present a challenge for efficient optimization solution techniques. This paper presents the application of metaheuristic approaches, such as a genetic algorithm (GA), simulated annealing (SA) and their hybrid for generator maintenance scheduling (GMS) in power systems using an integer representation. This paper mainly focuses on the application of GA/SA and GA/SA/heuristic hybrid approaches. GA/SA hybrid uses the probabilistic acceptance criterion of SA within the GA framework. GA/SA/heuristic hybrid combines heuristic approaches within the GA/SA hybrid to seed the initial population. A case study is formulated in this paper as an integer programming problem using a reliability-based objective function and typical problem constraints. The implementation and performance of the metaheuristic approaches and their hybrid for the test case study are discussed. The results obtained are promising and show that the hybrid approaches are less sensitive to the variations of technique parameters and offer an effective alternative for solving the generator maintenance scheduling problem. (author)

  16. Coordinated Stability Control of Wind-Thermal Hybrid AC/DC Power System

    Directory of Open Access Journals (Sweden)

    Zhiqing Yao

    2015-01-01

    Full Text Available The wind-thermal hybrid power transmission will someday be the main form of transmitting wind power in China but such transmission mode is poor in system stability. In this paper, a coordinated stability control strategy is proposed to improve the system stability. Firstly, the mathematical model of doubly fed wind farms and DC power transmission system is established. The rapid power controllability of large-scale wind farms is discussed based on DFIG model and wide-field optical fiber delay feature. Secondly, low frequency oscillation and power-angle stability are analyzed and discussed under the hybrid transmission mode of a conventional power plant with wind farms. A coordinated control strategy for the wind-thermal hybrid AC/DC power system is proposed and an experimental prototype is made. Finally, real time simulation modeling is set up through Real Time Digital Simulator (RTDS, including wind power system and synchronous generator system and DC power transmission system. The experimental prototype is connected with RTDS for joint debugging. Joint debugging result shows that, under the coordinated control strategy, the experimental prototype is conductive to enhance the grid damping and effectively prevents the grid from occurring low frequency oscillation. It can also increase the transient power-angle stability of a power system.

  17. Design, implementation, and experimental validation of optimal power split control for hybrid electric trucks

    NARCIS (Netherlands)

    Keulen, T. van; Mullem, D. van; Jager, B. van; Kessels, J.T.B.A.; Steinbuch, M.

    2012-01-01

    Hybrid electric vehicles require an algorithm that controls the power split between the internal combustion engine and electric machine(s), and the opening and closing of the clutch. Optimal control theory is applied to derive a methodology for a real-time optimal-control-based power split

  18. Modeling and Control of Cogeneration Power Plants: A Hybrid System Approach

    NARCIS (Netherlands)

    G. Ferrari-Trecate (Giancarlo); E. Gallestey (Eduardo); P. Letizia (Paolo); M. Spedicato (Matteo); M. Morari (Manfred); M. Antoine (Marc)

    2004-01-01

    textabstractIn this paper the short term scheduling optimization of a combined cycle power plant is accomplished by exploiting hybrid systems, i.e. systems evolving according to continuous dynamics, discrete dynamics, and logic rules. Discrete features of a power plant are, for instance, the possibi

  19. A Wireless Power Sharing Control Strategy for Hybrid Energy Storage Systems in DC Microgrids

    DEFF Research Database (Denmark)

    Yang, Jie; Jin, Xinmin; Wu, Xuezhi

    2017-01-01

    In order to compensate multiple time scales power fluctuation resulted from distributed energy resources and loads, hybrid energy storage systems are employed as the buffer unit in DC microgrid. In this paper, a wireless hierarchical control strategy is proposed to realize power sharing between...

  20. Power flow analysis for droop controlled LV hybrid AC-DC microgrids with virtual impedance

    DEFF Research Database (Denmark)

    Li, Chendan; Chaudhary, Sanjay; Vasquez, Juan Carlos

    2014-01-01

    The AC-DC hybrid microgrid is an effective form of utilizing different energy resources and the analysis of this system requires a proper power flow algorithm. This paper proposes a suitable power flow algorithm for LV hybrid AC-DC microgrid based on droop control and virtual impedance. Droop...... and virtual impedance concepts for AC network, DC network and interlinking converter are reviewed so as to model it in the power flow analysis. The validation of the algorithm is verified by comparing it with steady state results from detailed time domain simulation. The effectiveness of the proposed...

  1. Practice and Prospect of AC/DC Hybrid Power Grid in Southern China

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    China Southern Power Grid is a unique EHV AC/DC hybrid transmission network that operates in China. In its service area, the distribution of energy resources and the development of economy are extremely unbalanced, so long-distance and bulk power transmission are needed; besides, the geography and climate conditions are serious, rains, fogs, lightning and typhoon as well as high temperature are common all the year round. Facing these challenges,the power grid enhanced stability control, improved the equipment and strengthen the network structure. In the future, the power grid plans to optimize the disposition of power sources and build digitalized power system.

  2. Predictive control strategy for power management in parallel hybrid-electric vehicle

    DEFF Research Database (Denmark)

    Nodeh, Mohammad Taqi; Gholizade, Hossein; Hajizadeh, Amin

    2016-01-01

    In this paper, a hybrid model-based nonlinear optimal control method is used to compute the optimal power distribution and power management in parallel hybrid electric vehicles. In the power management strategy, for optimal power distribution between the internal combustion engine, electrical...... system and the other subsystems, nonlinear predictive control is applied. In order to achieve this goal, a hierarchical control structure is utilized. This type of control structure consists of three levels of monitoring, coordinating and local controllers. Nonlinear modeling and performance index...... in the proposed method should be formulated at the regulatory level of the controller. Discrete dynamic mode of operation (motor-generator) in hybrid electric vehicle requires to use a dual-mode switch model and to define an alternative expression of performance index for the optimal control problem...

  3. Hierarchical Control Strategy of Heat and Power for Zero Energy Buildings including Hybrid Fuel Cell/Photovoltaic Power Sources and Plug-in Electric Vehicle

    DEFF Research Database (Denmark)

    Ghiasi, Mohammad Iman; Aliakbar Golkar, Masoud; Hajizadeh, Amin

    2016-01-01

    complexities and uncertainties in this kind of hybrid system, a hybrid supervisory control with an adaptive fuzzy sliding power control strategy is proposed to regulate the amount of requested fuel from a fuel cell power source to produce the electrical power and heat. Then, simulation results are used......This paper presents a hierarchical control strategy for heat and electric power control of a building integrating hybrid renewable power sources including photovoltaic, fuel cell and battery energy storage with Plug-in Electric Vehicles (PEV) in smart distribution systems. Because...... of the controllability of fuel cell power, this power sources plays the main role for providing heat and electric power to zero emission buildings. First, the power flow structure between hybrid power resources is described. To do so, all necessary electrical and thermal equations are investigated. Next, due to the many...

  4. Hierarchical Control Strategy of Heat and Power for Zero Energy Buildings including Hybrid Fuel Cell/Photovoltaic Power Sources and Plug-in Electric Vehicle

    DEFF Research Database (Denmark)

    Ghiasi, Mohammad Iman; Aliakbar Golkar, Masoud; Hajizadeh, Amin

    2016-01-01

    This paper presents a hierarchical control strategy for heat and electric power control of a building integrating hybrid renewable power sources including photovoltaic, fuel cell and battery energy storage with Plug-in Electric Vehicles (PEV) in smart distribution systems. Because...... of the controllability of fuel cell power, this power sources plays the main role for providing heat and electric power to zero emission buildings. First, the power flow structure between hybrid power resources is described. To do so, all necessary electrical and thermal equations are investigated. Next, due to the many...... complexities and uncertainties in this kind of hybrid system, a hybrid supervisory control with an adaptive fuzzy sliding power control strategy is proposed to regulate the amount of requested fuel from a fuel cell power source to produce the electrical power and heat. Then, simulation results are used...

  5. Modeling,Analysis and Simulation ofThree Phase Hybrid Power Filter forPower Quality Improvement

    Directory of Open Access Journals (Sweden)

    Prashanta Kumar Das

    2012-05-01

    Full Text Available A three-phase hybrid series power filter is constituted by a series active filter and a passive filter connected in parallel with the load. The control strategy is based on the “dual formulation of the electric power vectorial theory”. The proposed algorithm eliminates the current harmonics of supply. It also improves the power factor and harmonic compensation features of the associated passive filter even if there is a change in system parameters.A shunt hybrid power filter is constituted by a shunt active filter and a passive filter connected in parallel with the load, is proposed with same control strategy. Simulations have been carried out on the MATLAB-SIMULINK platform with different loads and with variation in the source impedance.

  6. AN ASSESSMENT OF FLYWHEEL HIGH POWER ENERGY STORAGE TECHNOLOGY FOR HYBRID VEHICLES

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, James Gerald [ORNL

    2012-02-01

    An assessment has been conducted for the DOE Vehicle Technologies Program to determine the state of the art of advanced flywheel high power energy storage systems to meet hybrid vehicle needs for high power energy storage and energy/power management. Flywheel systems can be implemented with either an electrical or a mechanical powertrain. The assessment elaborates upon flywheel rotor design issues of stress, materials and aspect ratio. Twelve organizations that produce flywheel systems submitted specifications for flywheel energy storage systems to meet minimum energy and power requirements for both light-duty and heavy-duty hybrid applications of interest to DOE. The most extensive experience operating flywheel high power energy storage systems in heavy-duty and light-duty hybrid vehicles is in Europe. Recent advances in Europe in a number of vehicle racing venues and also in road car advanced evaluations are discussed. As a frame of reference, nominal weight and specific power for non-energy storage components of Toyota hybrid electric vehicles are summarized. The most effective utilization of flywheels is in providing high power while providing just enough energy storage to accomplish the power assist mission effectively. Flywheels are shown to meet or exceed the USABC power related goals (discharge power, regenerative power, specific power, power density, weight and volume) for HEV and EV batteries and ultracapacitors. The greatest technical challenge facing the developer of vehicular flywheel systems remains the issue of safety and containment. Flywheel safety issues must be addressed during the design and testing phases to ensure that production flywheel systems can be operated with adequately low risk.

  7. Experimental Study on a Passive Fuel Cell/Battery Hybrid Power System

    Directory of Open Access Journals (Sweden)

    Yong-Song Chen

    2013-12-01

    Full Text Available A laboratory-scale passive hybrid power system for transportation applications is constructed and tested in this study. The hybrid power system consists of a fuel cell stack connected with a diode, a lithium-ion battery pack connected with a DC/DC power converter and another diode. The power converter is employed to regulate the output voltage of the battery pack. The dynamic responses of current and voltage of the stack to the start-up and acceleration of the load are experimentally investigated at two different selected output voltages of the DC/DC converter in the battery line. The power sharing of each power source and efficiency are also analyzed and discussed. Experimental results show that the battery can compensate for the shortage of supplied power for the load demand during the start-up and acceleration. The lowest operating voltage of the fuel cell stack is limited by the regulated output voltage of the DC/DC converter. The major power loss in the hybrid power system is attributed to the diodes. The power train efficiency can be improved by lowering the ratio of forward voltage drop of the diode to the operating voltage of the fuel cell stack.

  8. Solar central receiver hybrid power system, Phase I. Volume 3. Appendices. Final technical report, October 1978-August 1979

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-09-01

    A design study for a central receiver/fossil fuel hybrid power system using molten salts for heat transfer and heat storage is presented. This volume contains the appendices: (A) parametric salt piping data; (B) sample heat exchanger calculations; (C) salt chemistry and salt/materials compatibility evaluation; (D) heliostat field coordinates; (E) data lists; (F) STEAEC program input data; (G) hybrid receiver design drawings; (H) hybrid receiver absorber tube thermal math model; (I) piping stress analysis; (J) 100-MWe 18-hour storage solar central receiver hybrid power system capital cost worksheets; and (K) 500-MWe 18-hour solar central receiver hybrid power system cost breakdown. (WHK)

  9. Hybrid Active and Passive Control of Vibratory Power Flow in Flexible Isolation System

    Directory of Open Access Journals (Sweden)

    Y.P. Xiong

    2000-01-01

    Full Text Available A hybrid active and passive vibration control strategy is developed to reduce the total power flows from machines, subject to multiple excitations, to supporting flexible structures. The dynamic interactions between machines, controllers, and receiving structures are studied. A force feedback control process governed by a proportional control law is adopted to produce active control forces to cancel the transmitted forces in the mounts. Computational simulations of a simple and a multiple dimensional hybrid vibration isolation system are performed to study the force transmissibility and the total power flows from vibration sources through active and passive isolators to the supporting structures. The investigation focuses on the effects of a hybrid control approach to the reduction of power flow transmissions and the influence of the dynamic characteristics of the control on power flow spectra. The hybrid control mechanism is synthesised from the power flow analysis. Conclusions and control strategies, well supported by numerical simulations, are deduced providing very useful guidelines for hybrid vibration isolation design.

  10. Hybridized electromagnetic-triboelectric nanogenerator for scavenging biomechanical energy for sustainably powering wearable electronics.

    Science.gov (United States)

    Zhang, Kewei; Wang, Xue; Yang, Ya; Wang, Zhong Lin

    2015-01-01

    We report a hybridized electromagnetic-triboelectric nanogenerator for highly efficient scavenging of biomechanical energy to sustainably power wearable electronics by human walking. Based on the effective conjunction of triboelectrification and electromagnetic induction, the hybridized nanogenerator, with dimensions of 5 cm × 5 cm × 2.5 cm and a light weight of 60 g, integrates a triboelectric nanogenerator (TENG) that can deliver a peak output power of 4.9 mW under a loading resistance of 6 MΩ and an electromagnetic generator (EMG) that can deliver a peak output power of 3.5 mW under a loading resistance of 2 kΩ. The hybridized nanogenerator exhibits a good stability for the output performance and a much better charging performance than that of an individual energy-harvesting unit (TENG or EMG). Furthermore, the hybridized nanogenerator integrated in a commercial shoe has been utilized to harvest biomechanical energy induced by human walking to directly light up tens of light-emitting diodes in the shoe and sustainably power a smart pedometer for reading the data of a walking step, distance, and energy consumption. A wireless pedometer driven by the hybrid nanogenerator can work well to send the walking data to an iPhone under the distance of 25 m. This work pushes forward a significant step toward energy harvesting from human walking and its potential applications in sustainably powering wearable electronics.

  11. IMPLEMENTATION OF ENERGY LAW OF HYBRID POWER STATION FOR SOCIAL WELFARE

    Directory of Open Access Journals (Sweden)

    Dyah Ayu Widowati

    2014-11-01

    Full Text Available This study was aimed to investigate the Implementation of Energy Law of Hybrid Power Station for Social Welfare in Pantai Baru. The problem formulations are the management and utilization of hybrid power station in Pantai Baru and implementation of energy law of hybrid power station for social welfare in the fields of economy and information in Pantai Baru. Based on data analysis it is concluded that the management of hybrid power station in Pantai Baru is performed collaboratively between government and the society. The existence of hybrid power station in pantai baru has positive impacts in economy and information. Penelitian ini meneliti Pelaksanaan Hukum Energi Pembangkit Listrik Tenaga Hibrid untuk Kesejahteraan Rakyat di Bidang Ekonomi dan Informasi di Pantai Baru. Masalah yang diteliti adalah bentuk pengelolaan dan pemanfaatan pembangkit listrik tenaga hibrid di Pantai Baru dan pelaksanaan hukum energi pembangkit listrik tenaga hibrid untuk kesejahteraan rakyat di bidang ekonomi dan informasi di Pantai Baru. Berdasarkan analisis data dapat disimpulkan bahwa pengelolaan pembangkit listrik tenaga hibrid yang ada di pantai baru dilakukan secara kolaboratif, antara pemerintah dengan masyarakat. Kehadiran pembangkit listrik tenaga hibrid yang ada di pantai baru telah memberikan dampak positif di bidang ekonomi dan informasi.

  12. Grid-Connected Pv-Fc Hybrid System Power Control Using Mppt And Boost Converter

    Directory of Open Access Journals (Sweden)

    P.HARIKA

    2014-09-01

    Full Text Available This paper proposes a method for operating a grid connected hybrid system. This system composed of a Photovoltaic (PV array and a Proton exchange membrane fuel cell (PEMFC is considered. As the variations occur in temperature and irradiation during power delivery to load, Photo voltaic (PV system becomes uncontrollable. In coordination with PEMFC, the hybrid system output power becomes controllable. Two operation modes are the unit-power control (UPC mode and the feeder-flow control (FFC mode, can be applied to the hybrid system. All MPPT methods follow the same goal that is maximizing the PV system output power by tracking the maximum power on every operating condition. Maximum power point tracking technique (Incremental conductance for photovoltaic systems was introduced to maximize the produced energy. The coordination of two control modes, coordination of the PV array and the PEMFC in the hybrid system, and determination of reference parameters are presented. The proposed operating strategy systems with a flexible operation mode change always operate the PV array at maximum output power and the PEMFC in its high efficiency performance band. Also thus improving the performance of system operation, enhancing system stability, and reducing the number of operating mode changes.

  13. Design and evaluation of hybrid wind/PV/diesel power systems for Brazilian applications

    Energy Technology Data Exchange (ETDEWEB)

    McGowan, J.G.; Manwell, J.F.; Avelar, C. [Univ. of Massachusetts, Amherst, MA (United States); Warner, C. [National Renewable Energy Lab., Golden, CO (United States)

    1996-12-31

    This paper presents a summary of a study centered on the design and evaluation of hybrid wind/PV/diesel systems for remote locations in Brazil. The objective of this work was to evaluate high reliability hybrid power systems that have been designed for the lowest life cycle costs. The technical and economic analysis of the hybrid wind/PV/diesel systems was carried out using HYBRID2, a computational code developed at the University of Massachusetts in conjunction with the National Renewable Energy Laboratory (NREL). After a summary of a generalized design procedure for such systems based on the use of this code, a systematic parametric evaluation of a representative design case for a village power system in Brazil is presented. As summarized in the paper, the performance and economic effects of key design parameters are illustrated. 8 refs., 10 figs.

  14. Compound hybrid geothermal-fossil power plants - Thermodynamic analyses and site-specific applications

    Science.gov (United States)

    Dipippo, R.; Kestin, J.; Avelar, E. M.; Khalifa, H. E.

    1980-02-01

    In this paper, we extend the analysis of hybrid fossil-geothermal power plants to compound systems which combine the features of the two previously analyzed hybrid plants, the geothermal preheat and the fossil superheat systems. Compound systems of the one- and two-stage type are considered. A complete summary of formulae to assess the performance of the plants is included for completeness. From the viewpoint of thermodynamics, compound hybrid plants are superior to individual all-geothermal and all-fossil plants, and have certain advantages over basic geothermal-preheat and fossil-superheat hybrid plants. The flexibility of compound hybrid systems is illustrated by showing how such plants might be used at several geothermal sites in the western United States.

  15. Efficiency Characteristics of Low Power Hybrid Switched Reluctance Motor

    DEFF Research Database (Denmark)

    Jakobsen, Uffe; Ahn, Jin-Woo

    2009-01-01

    Switched reluctance motors (SRM) are usually considered inferior in terms of efficiency as compared to permanent magnet synchronous motors (PMSM) and brushless DC-motors (BLDC), but less costly. This article presents a test of a 70W hybrid switched reluctance motor (HSRM), that archieves a peak...... efficiency for the motor drive of more than 74%, and an efficiency for the motor of almost 80%....

  16. Kinetic energy recovery and power management for hybrid electric vehicles

    OpenAIRE

    P. Suntharalingam

    2011-01-01

    The major contribution of the work presented in this thesis is a thorough investigation of the constraints on regenerative braking and kinetic energy recovery enhancement for electric/hybrid electric vehicles during braking. Regenerative braking systems provide an opportunity to recycle the braking energy, which is otherwise dissipated as heat in the brake pads. However, braking energy harnessing is a relatively new concept in the automotive sector which still requires further research and de...

  17. Hybrid Nonlinear Optical Materials for Applications in Power Limiting and Photorefractive Devices

    Science.gov (United States)

    2010-03-01

    Final 3. DATES COVERED (From - To) 04/01/2007 to 11/30/2009 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER FA9550-07-1-0307 Hybrid Nonlinear Optical Materials for...Hybrid  Nonlinear   Optical   Materials  for Applications in Power  Limiting and Photorefractive devices      Prime Contract: FA95500710307

  18. Power electronics for renewable and distributed energy systems a sourcebook of topologies, control and integration

    CERN Document Server

    Chakraborty, Sudipta; Kramer, William E

    2013-01-01

    While most books approach power electronics and renewable energy as two separate subjects, Power Electronics for Renewable and Distributed Energy Systems takes an integrative approach; discussing power electronic converters topologies, controls and integration that are specific to the renewable and distributed energy system applications. An overview of power electronic technologies is followed by the introduction of various renewable and distributed energy resources that includes photovoltaics, wind, small hydroelectric, fuel cells, microturbines and variable speed generation. Energy storage s

  19. Optical fiber-based core-shell coaxially structured hybrid cells for self-powered nanosystems

    Energy Technology Data Exchange (ETDEWEB)

    Pan, Caofeng; Zhu, Guang [School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, Georgia (United States); Guo, Wenxi [School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, Georgia (United States); State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005 (China); Dong, Lin [School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, Georgia (United States); School of Materials Science and Enginnering, Zhenzhou University, Zhenghou 450001 (China); Wang, Zhong Lin [School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, Georgia (United States); Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing (China)

    2012-07-03

    An optical fiber-based 3D hybrid cell consisting of a coaxially structured dye-sensitized solar cell (DSSC) and a nanogenerator (NG) for simultaneously or independently harvesting solar and mechanical energy is demonstrated. The current output of the hybrid cell is dominated by the DSSC, and the voltage output is dominated by the NG; these can be utilized complementarily for different applications. The output of the hybrid cell is about 7.65 {mu}A current and 3.3 V voltage, which is strong enough to power nanodevices and even commercial electronic components. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  20. Sensitivity of Exponents of Three-Power Laws to Hybrid Ratio in Weighted HUHPM

    Institute of Scientific and Technical Information of China (English)

    FANG Jin-Qing; BI Qiao; LI Yong; LU Xin-Biao; LIU Qiang

    2007-01-01

    @@ The sensitivity of exponents of three-power laws for node degree, node strength and edged weight to hybrid ratio are studied analytically and numerically in the weighted harmonious unifying hybrid preferential model (HUHPM), which is extended from un-weighted hybrid preferential attachment model we proposed previously [Chin. Phys. Lett. 22 (2005)719]. Our weighted HUHPMs plus the Barrat-Barthelemy-Vespignani model and the traffic-driven evolution model, respectively, are taken as two typical examples for demonstration and application of the HUHPM.

  1. Combined cycle solar central receiver hybrid power system study. Final technical report. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-11-01

    This study develops the conceptual design for a commercial-scale (nominal 100 MWe) central receiver solar/fossil fuel hybrid power system with combined cycle energy conversion. A near-term, metallic heat pipe receiver and an advanced ceramic tube receiver hybrid system are defined through parametric and market potential analyses. Comparative evaluations of the cost of power generation, the fuel displacement potential, and the technological readiness of these two systems indicate that the near-term hybrid system has better potential for commercialization by 1990. Based on the assessment of the conceptual design, major cost and performance improvements are projected for the near-term system. Constraints preventing wide-spread use were not identified. Energy storage is not required for this system and analyses show no economic advantages with energy storage provisions. It is concluded that the solar hybrid system is a cost effective alternative to conventional gas turbines and combined cycle generating plants, and has potential for intermediate-load market penetration at 15% annual fuel escalation rate. Due to their flexibility, simple solar/nonsolar interfacing, and short startup cycles, these hybrid plants have significant operating advantages. Utility company comments suggest that hybrid power systems will precede stand-alone solar plants.

  2. Preconstruction of the Honey Lake Hybrid Power Plant: Final report

    Energy Technology Data Exchange (ETDEWEB)

    1988-04-30

    The work undertaken under this Contract is the prosecution of the preconstruction activities, including preliminary engineering design, well field development, completion of environmental review and prosecution of permits, and the economic and financial analysis of the facility. The proposed power plant is located in northeastern California in Lassen County, approximately 25 miles east of the town of Susanville. The power plant will use a combination of wood residue and geothermal fluids for power generation. The plant, when fully constructed, will generate a combined net output of approximately 33 megawatts which will be sold to Pacific Gas and Electric Company (PGandE) under existing long-term power sales contracts. Transfer of electricity to the PGandE grid will require construction of a 22-mile transmission line from the power plant to Susanville. 11 refs., 12 figs., 4 tabs.

  3. Hybrid zero-voltage switching (ZVS) control for power inverters

    Science.gov (United States)

    Amirahmadi, Ahmadreza; Hu, Haibing; Batarseh, Issa

    2016-11-01

    A power inverter combination includes a half-bridge power inverter including first and second semiconductor power switches receiving input power having an intermediate node therebetween providing an inductor current through an inductor. A controller includes input comparison circuitry receiving the inductor current having outputs coupled to first inputs of pulse width modulation (PWM) generation circuitry, and a predictive control block having an output coupled to second inputs of the PWM generation circuitry. The predictive control block is coupled to receive a measure of Vin and an output voltage at a grid connection point. A memory stores a current control algorithm configured for resetting a PWM period for a switching signal applied to control nodes of the first and second power switch whenever the inductor current reaches a predetermined upper limit or a predetermined lower limit.

  4. Optimization of wind-marine hybrid power system configuration based on genetic algorithm

    Science.gov (United States)

    Shi, Hongda; Li, Linna; Zhao, Chenyu

    2017-08-01

    Multi-energy power systems can use energy generated from various sources to improve power generation reliability. This paper presents a cost-power generation model of a wind-tide-wave energy hybrid power system for use on a remote island, where the configuration is optimized using a genetic algorithm. A mixed integer programming model is used and a novel object function, including cost and power generation, is proposed to solve the boundary problem caused by existence of two goals. Using this model, the final optimized result is found to have a good fit with local resources.

  5. Ultra-Short-Term Wind Power Prediction Using a Hybrid Model

    Science.gov (United States)

    Mohammed, E.; Wang, S.; Yu, J.

    2017-05-01

    This paper aims to develop and apply a hybrid model of two data analytical methods, multiple linear regressions and least square (MLR&LS), for ultra-short-term wind power prediction (WPP), for example taking, Northeast China electricity demand. The data was obtained from the historical records of wind power from an offshore region, and from a wind farm of the wind power plant in the areas. The WPP achieved in two stages: first, the ratios of wind power were forecasted using the proposed hybrid method, and then the transformation of these ratios of wind power to obtain forecasted values. The hybrid model combines the persistence methods, MLR and LS. The proposed method included two prediction types, multi-point prediction and single-point prediction. WPP is tested by applying different models such as autoregressive moving average (ARMA), autoregressive integrated moving average (ARIMA) and artificial neural network (ANN). By comparing results of the above models, the validity of the proposed hybrid model is confirmed in terms of error and correlation coefficient. Comparison of results confirmed that the proposed method works effectively. Additional, forecasting errors were also computed and compared, to improve understanding of how to depict highly variable WPP and the correlations between actual and predicted wind power.

  6. Hybridized electromagnetic-triboelectric nanogenerator for scavenging air-flow energy to sustainably power temperature sensors.

    Science.gov (United States)

    Wang, Xue; Wang, Shuhua; Yang, Ya; Wang, Zhong Lin

    2015-04-28

    We report a hybridized nanogenerator with dimensions of 6.7 cm × 4.5 cm × 2 cm and a weight of 42.3 g that consists of two triboelectric nanogenerators (TENGs) and two electromagnetic generators (EMGs) for scavenging air-flow energy. Under an air-flow speed of about 18 m/s, the hybridized nanogenerator can deliver largest output powers of 3.5 mW for one TENG (in correspondence of power per unit mass/volume: 8.8 mW/g and 14.6 kW/m(3)) at a loading resistance of 3 MΩ and 1.8 mW for one EMG (in correspondence of power per unit mass/volume: 0.3 mW/g and 0.4 kW/m(3)) at a loading resistance of 2 kΩ, respectively. The hybridized nanogenerator can be utilized to charge a capacitor of 3300 μF to sustainably power four temperature sensors for realizing self-powered temperature sensor networks. Moreover, a wireless temperature sensor driven by a hybridized nanogenerator charged Li-ion battery can work well to send the temperature data to a receiver/computer at a distance of 1.5 m. This work takes a significant step toward air-flow energy harvesting and its potential applications in self-powered wireless sensor networks.

  7. A Frequency Control Approach for Hybrid Power System Using Multi-Objective Optimization

    Directory of Open Access Journals (Sweden)

    Mohammed Elsayed Lotfy

    2017-01-01

    Full Text Available A hybrid power system uses many wind turbine generators (WTG and solar photovoltaics (PV in isolated small areas. However, the output power of these renewable sources is not constant and can diverge quickly, which has a serious effect on system frequency and the continuity of demand supply. In order to solve this problem, this paper presents a new frequency control scheme for a hybrid power system to ensure supplying a high-quality power in isolated areas. The proposed power system consists of a WTG, PV, aqua-electrolyzer (AE, fuel cell (FC, battery energy storage system (BESS, flywheel (FW and diesel engine generator (DEG. Furthermore, plug-in hybrid electric vehicles (EVs are implemented at the customer side. A full-order observer is utilized to estimate the supply error. Then, the estimated supply error is considered in a frequency domain. The high-frequency component is reduced by BESS and FW; while the low-frequency component of supply error is mitigated using FC, EV and DEG. Two PI controllers are implemented in the proposed system to control the system frequency and reduce the supply error. The epsilon multi-objective genetic algorithm ( ε -MOGA is applied to optimize the controllers’ parameters. The performance of the proposed control scheme is compared with that of recent well-established techniques, such as a PID controller tuned by the quasi-oppositional harmony search algorithm (QOHSA. The effectiveness and robustness of the hybrid power system are investigated under various operating conditions.

  8. A Wind Power and Load Prediction Based Frequency Control Approach for Wind-Diesel-Battery Hybrid Power System

    Directory of Open Access Journals (Sweden)

    Chao Peng

    2015-01-01

    Full Text Available A frequency control approach based on wind power and load power prediction information is proposed for wind-diesel-battery hybrid power system (WDBHPS. To maintain the frequency stability by wind power and diesel generation as much as possible, a fuzzy control theory based wind and diesel power control module is designed according to wind power and load prediction information. To compensate frequency fluctuation in real time and enhance system disturbance rejection ability, a battery energy storage system real-time control module is designed based on ADRC (active disturbance rejection control. The simulation experiment results demonstrate that the proposed approach has a better disturbance rejection ability and frequency control performance compared with the traditional droop control approach.

  9. PV-hybrid village power systems in Amazonia

    Energy Technology Data Exchange (ETDEWEB)

    Warner, C.L.; Taylor, R.W. [National Renewable Energy Lab., Golden, CO (United States); Ribeiro, C.M. [Centro de Pesquisas de Energie Eletrica (CEPEL), Rio de Janeiro (Brazil)] [and others

    1996-05-01

    The Brazilian Amazon region is an ideal location for isolated mini-grid systems. Hundreds of diesel systems have been installed to supply electricity to this sparsely populated region. However, the availability of renewable energy resources makes the Amazon well-suited to renewable energy systems. This paper describes the technical aspects of two hybrid systems being installed in this region through the cooperative effort of multiple partners: U.S. Department of Energy, through NREL, and Brazilian CEPEL/Eletrobras and state electric utilities.

  10. Yeast Two-Hybrid, a Powerful Tool for Systems Biology

    Directory of Open Access Journals (Sweden)

    Uwe Schlattner

    2009-06-01

    Full Text Available A key property of complex biological systems is the presence of interaction networks formed by its different components, primarily proteins. These are crucial for all levels of cellular function, including architecture, metabolism and signalling, as well as the availability of cellular energy. Very stable, but also rather transient and dynamic protein-protein interactions generate new system properties at the level of multiprotein complexes, cellular compartments or the entire cell. Thus, interactomics is expected to largely contribute to emerging fields like systems biology or systems bioenergetics. The more recent technological development of high-throughput methods for interactomics research will dramatically increase our knowledge of protein interaction networks. The two most frequently used methods are yeast two-hybrid (Y2H screening, a well established genetic in vivo approach, and affinity purification of complexes followed by mass spectrometry analysis, an emerging biochemical in vitro technique. So far, a majority of published interactions have been detected using an Y2H screen. However, with the massive application of this method, also some limitations have become apparent. This review provides an overview on available yeast two-hybrid methods, in particular focusing on more recent approaches. These allow detection of protein interactions in their native environment, as e.g. in the cytosol or bound to a membrane, by using cytosolic signalling cascades or split protein constructs. Strengths and weaknesses of these genetic methods are discussed and some guidelines for verification of detected protein-protein interactions are provided.

  11. Compound hybrid geothermal-fossil power plants: thermodynamic analyses and site-specific applications

    Energy Technology Data Exchange (ETDEWEB)

    DiPippo, R.; Avelar, E.M.

    1979-06-01

    The analysis of hybrid fossil-geothermal power plants is extended to compound hybrid systems which combine the features of previously analyzed systems: the geothermal-preheat and the fossil-superheat systems. Compound systems of the one- and two-stage type are considered. A compilation of working formulae from earlier studies is included for completeness. Results are given for parametric analyses of compound hybrid plants. System performance was determined for wellhead conditions of 150, 200, and 250/sup 0/C, and for steam fractions of 10, 20, 30, and 40%. For two-stage systems an additional cycle variable, the hot water flash fraction, was varied from 0 to 100% in increments of 25%. From the viewpoint of thermodynamics, compound hybrid plants are superior to individual all-geothermal and all-fossil plants, and are shown to have certain advantages over basic geothermal-preheat and fossil-superheat hybrid plants. The flexibility of compound hybrid systems is illustrated by showing how such plants might be used at six geothermal sites in the western United States. The question of the optimum match between the energy resources and the power plant is addressed, and an analysis given for a hypothetical geothermal resource.

  12. Self-Powered Safety Helmet Based on Hybridized Nanogenerator for Emergency.

    Science.gov (United States)

    Jin, Long; Chen, Jun; Zhang, Binbin; Deng, Weili; Zhang, Lei; Zhang, Haitao; Huang, Xi; Zhu, Minhao; Yang, Weiqing; Wang, Zhong Lin

    2016-08-23

    The rapid development of Internet of Things and the related sensor technology requires sustainable power sources for their continuous operation. Scavenging and utilizing the ambient environmental energy could be a superior solution. Here, we report a self-powered helmet for emergency, which was powered by the energy converted from ambient mechanical vibration via a hybridized nanogenerator that consists of a triboelectric nanogenerator (TENG) and an electromagnetic generator (EMG). Integrating with transformers and rectifiers, the hybridized nanogenerator can deliver a power density up to 167.22 W/m(3), which was demonstrated to light up 1000 commercial light-emitting diodes (LEDs) instantaneously. By wearing the developed safety helmet, equipped with rationally designed hybridized nanogenerator, the harvested vibration energy from natural human motion is also capable of powering a wireless pedometer for real-time transmitting data reporting to a personal cell phone. Without adding much extra weight to a commercial one, the developed wearing helmet can be a superior sustainable power source for explorers, engineers, mine-workers under well, as well as and disaster-relief workers, especially in remote areas. This work not only presents a significant step toward energy harvesting from human biomechanical movement, but also greatly expands the applicability of TENGs as power sources for self-sustained electronics.

  13. Using hydropower to complement wind energy: a hybrid system to provide firm power

    Energy Technology Data Exchange (ETDEWEB)

    Jaramillo, O.A.; Borja, M.A.; Huacuz, J.M. [Instituto de Investigaciones Electricas, Morelos (Mexico). Energias No Convencionales

    2004-09-01

    This paper presents a theoretical study of how wind power can be complemented by hydropower. A conceptual framework is provided for a hybrid power station that produces constant power output without the intermittent fluctuations inherent when using wind power. Two hypothetical facilities are considered as case studies. One of them is a hydropower plant located on the ''Presidente Benito Juarez'' dam in Jalapa del Marques, Oaxaca, Mexico. The other hypothetical facility is a wind farm located near ''La Venta's', an area in Juchitan, Oaxaca, Mexico. The wind-hydro-power system is a combined wind and hydro power plant in a region that is rich in both resources. The model shows that the hybrid plant could provide close to 20 MW of firm power to the electrical distribution system. On a techno-economic basis, we obtain the levelized production cost of the hybrid system. Taking into account two different discount rates of 7% and 10%, figures for levelized production cost are developed. (author)

  14. Short-Term Wind Power Forecasting Using the Enhanced Particle Swarm Optimization Based Hybrid Method

    Directory of Open Access Journals (Sweden)

    Wen-Yeau Chang

    2013-09-01

    Full Text Available High penetration of wind power in the electricity system provides many challenges to power system operators, mainly due to the unpredictability and variability of wind power generation. Although wind energy may not be dispatched, an accurate forecasting method of wind speed and power generation can help power system operators reduce the risk of an unreliable electricity supply. This paper proposes an enhanced particle swarm optimization (EPSO based hybrid forecasting method for short-term wind power forecasting. The hybrid forecasting method combines the persistence method, the back propagation neural network, and the radial basis function (RBF neural network. The EPSO algorithm is employed to optimize the weight coefficients in the hybrid forecasting method. To demonstrate the effectiveness of the proposed method, the method is tested on the practical information of wind power generation of a wind energy conversion system (WECS installed on the Taichung coast of Taiwan. Comparisons of forecasting performance are made with the individual forecasting methods. Good agreements between the realistic values and forecasting values are obtained; the test results show the proposed forecasting method is accurate and reliable.

  15. Pulse Power Hybrid Energy Storage Module Development Program

    Science.gov (United States)

    2015-05-01

    simulation results were shown in Fig. 11.) 28 14. One of the two reference MatLab Simulink models for the study of the effect of HESMs and a pulsed load...the Megawatt Power Module 44 25 Block diagram of the MPM system - two flywheels per skid configuration 45 26 MatLab Simulink model of a two...Network McKttile Fig. 14. One of the two reference MatLab Simulink models for the study of the effect of HESMs and a pulsed load on a ship’s power

  16. Transmission Technologies and Operational Characteristic Analysis of Hybrid UHV AC/DC Power Grids in China

    Science.gov (United States)

    Tian, Zhang; Yanfeng, Gong

    2017-05-01

    In order to solve the contradiction between demand and distribution range of primary energy resource, Ultra High Voltage (UHV) power grids should be developed rapidly to meet development of energy bases and accessing of large-scale renewable energy. This paper reviewed the latest research processes of AC/DC transmission technologies, summarized the characteristics of AC/DC power grids, concluded that China’s power grids certainly enter a new period of large -scale hybrid UHV AC/DC power grids and characteristics of “strong DC and weak AC” becomes increasingly pro minent; possible problems in operation of AC/DC power grids was discussed, and interaction or effect between AC/DC power grids was made an intensive study of; according to above problems in operation of power grids, preliminary scheme is summarized as fo llows: strengthening backbone structures, enhancing AC/DC transmission technologies, promoting protection measures of clean energ y accessing grids, and taking actions to solve stability problems of voltage and frequency etc. It’s valuable for making hybrid UHV AC/DC power grids adapt to operating mode of large power grids, thus guaranteeing security and stability of power system.

  17. Power control method on VSC-HVDC in a hybrid multi-infeed HVDC system

    DEFF Research Database (Denmark)

    Liu, Yan; Chen, Zhe

    2012-01-01

    Multi-infeed HVDC (MIDC) system connected with VSC-HVDC links and LCC-HVDC links is a new structure in modern power systems, which can be called hybrid multi-infeed HVDC (HMIDC) system. The paper presents the voltage stability analysis of a HMIDC system modeled from a possible future Danish power...... stability of the system with induction machine loads. The proposed power control method based on a VSC power circle makes fully use of the VSC-HVDC capacity to support system voltage during fault situations. Simulation model of the studied HMIDC system is built in PSCAD. Simulation studies under different...

  18. Development of Control Structure for Hybrid Wind Generators with Active Power Capability

    Directory of Open Access Journals (Sweden)

    Mehdi Niroomand

    2014-01-01

    Full Text Available A hierarchical control structure is proposed for hybrid energy systems (HES which consist of wind energy system (WES and energy storage system (ESS. The proposed multilevel control structure consists of four blocks: reference generation and mode select, power balancing, control algorithms, and switching control blocks. A high performance power management strategy is used for the system. Also, the proposed system is analyzed as an active power filter (APF with ability to control the voltage, to compensate the harmonics, and to deliver active power. The HES is designed with parallel DC coupled structure. Simulation results are shown for verification of the theoretical analysis.

  19. Analysis, control and optimal operations in hybrid power systems advanced techniques and applications for linear and nonlinear systems

    CERN Document Server

    Bizon, Nicu; Mahdavi Tabatabaei, Naser

    2014-01-01

    This book explains and analyzes the dynamic performance of linear and nonlinear systems, particularly for Power Systems including Hybrid Power Sources. Offers a detailed description of system stability using state space energy conservation principle, and more.

  20. Experimental investigation on thermoelectric generator of micro hybrid power source

    Science.gov (United States)

    Shang, Yonghong; Li, Yanqiu; Yu, Hongyun; Sun, Hongguang; Su, Bo

    2007-12-01

    The micro power system, which is composed of photovoltaic solar cell, heat conductor, thermoelectric generator (TEG) module and fin heat sink has been developed in our laboratory. A photovoltaic silicon solar cell of the P-N junction type is sensitive to radiant energy of wavelength from 5,000 Å to 12,000 Å. Radiation under and within this range is converted not only into electric energy but also into heat energy. The wavelength longer than this range is also converted into heat energy, which degrades the conversion efficiency of the solar cell. TEG produces electrical power from temperature difference via Seebeck effect that can be put under the solar cell to absorb the heat. The heat energy can be converted into electrical power. It was found that when TEG surface area was 150mm×60mm, it could generate 0.24V output voltage and 4.18mA short circuit at ambient temperature varying between 5-10°C at winter. It also could generate 1.3V output voltage and 16mA short circuit at ambient temperature varying between 30-36°C at summer. In fact we can use a dc-dc boost up converter to enlarge the output voltage to meet the requirements of wireless sensor network nodes or its recharging battery. It will be an alternative power source for many portable electronic types of equipment.

  1. Four-branch Star Hybrid Power Filter for Three-phase Four-wire Systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Teodorescu, Remus; Rodriguez, Pedro;

    2008-01-01

    This paper presents a new concept for filtering current harmonics in three-phase four-wire networks. The four-branch star (FBS) filtering topology presented in this work is characterized by a particular layout consisting of single-phase inductances and capacitors. Via this layout, a power filter...... results is conducted in order to verify and validate the good performance of the proposed four-branch star passive/hybrid power filter....

  2. Geothermal Risk Reduction via Geothermal/Solar Hybrid Power Plants. Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Wendt, Daniel [Idaho National Lab. (INL), Idaho Falls, ID (United States); Mines, Greg [Idaho National Lab. (INL), Idaho Falls, ID (United States); Turchi, Craig [National Renewable Energy Lab. (NREL), Golden, CO (United States); Zhu, Guangdong [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-11-01

    There are numerous technical merits associated with a renewable geothermal-solar hybrid plant concept. The performance of air-cooled binary plants is lowest when ambient temperatures are high due to the decrease in air-cooled binary plant performance that occurs when the working fluid condensing temperature, and consequently the turbine exhaust pressure, increases. Electrical power demand is generally at peak levels during periods of elevated ambient temperature and it is therefore especially important to utilities to be able to provide electrical power during these periods. The time periods in which air-cooled binary geothermal power plant performance is lowest generally correspond to periods of high solar insolation. Use of solar heat to increase air-cooled geothermal power plant performance during these periods can improve the correlation between power plant output and utility load curves. While solar energy is a renewable energy source with long term performance that can be accurately characterized, on shorter time scales of hours or days it can be highly intermittent. Concentrating solar power (CSP), aka solar-thermal, plants often incorporate thermal energy storage to ensure continued operation during cloud events or after sunset. Hybridization with a geothermal power plant can eliminate the need for thermal storage due to the constant availability of geothermal heat. In addition to the elimination of the requirement for solar thermal storage, the ability of a geothermal/solar-thermal hybrid plant to share a common power block can reduce capital costs relative to separate, stand-alone geothermal and solar-thermal power plant installations. The common occurrence of long-term geothermal resource productivity decline provides additional motivation to consider the use of hybrid power plants in geothermal power production. Geothermal resource productivity decline is a source of significant risk in geothermal power generation. Many, if not all, geothermal resources

  3. Coordination of the STATCOM and Power System Stabilizer Using Hybrid BF-NM Algorithm

    Directory of Open Access Journals (Sweden)

    Mohammdjavad Morshed

    2011-05-01

    Full Text Available Recent developments of Facts devices increase the importance of their coordination with the power system controllers. With regard to nonlinearities of power system, changes in the operating points, reaction between power system and STATCOM, linear methods cannot be used to design parameters of stabilizers. Therefore, in this paper, a nonlinear model of power system is considered for the coordination design of PSS and STATCOM. A hybrid method which combines bacterial foraging (BF algorithm with Nelder-Mead (NM method (BF-NM is employed to coordinately design the PSS and STATCOM controllers. By combining these two methods, the search power of the intelligent methods and the precision of conventional methods are simultaneously employed. To evaluate the performance of the proposed method, it is applied on a four machine power system. Simulation results confirm the efficiency of the proposed method for stabilizing power system oscillations.

  4. A Self-Powered Hybrid Energy Scavenging System Utilizing RF and Vibration Based Electromagnetic Harvesters

    Science.gov (United States)

    Uluşan, H.; Gharehbaghi, K.; Zorlu, Ö.; Muhtaroğlu, A.; Külah, H.

    2015-12-01

    This study presents a novel hybrid system that combines the power generated simultaneously by a vibration-based Electromagnetic (EM) harvester and a UHF band RF harvester. The novel hybrid scavenger interface uses a power management circuit in 180 nm CMOS technology to step-up and to regulate the combined output. At the first stage of the system, the RF harvester generates positive DC output with a 7-stage threshold compensated rectifier, while the EM harvester generates negative DC output with a self-powered AC/DC negative doubler circuit. At the second stage, the generated voltages are serially added, stepped-up with an on-chip charge pump circuit, and regulated to a typical battery voltage of 3 V. Test results indicate that the hybrid operation enables generation of 9 μW at 3 V output for a wide range of input stimulations, which could not be attained with either harvesting mode by itself. Moreover the hybrid system behaves as a typical battery, and keeps the output voltage stable at 3 V up to 18 μW of output power. The presented system is the first battery-like harvester to our knowledge that generates energy from two independent sources and regulates the output to a stable DC voltage.

  5. Optimization of PV/WIND/DIESEL Hybrid Power System in HOMER for Rural Electrification

    Science.gov (United States)

    Hassan, Q.; Jaszczur, M.; Abdulateef, J.

    2016-09-01

    A large proportion of the world's population lives in remote rural areas that are geographically isolated and sparsely populated. The present study is based on modeling, computer simulation and optimization of hybrid power generation system in the rural area in Muqdadiyah district of Diyala state, Iraq. Two renewable resources, namely, solar photovoltaic (PV) and wind turbine (WT) are considered. The HOMER software is used to study and design the proposed hybrid energy system model. Based on simulation results, it has been found that renewable energy sources perhaps replace the conventional energy sources and would be a feasible solution for the generation of electric power at remote locations with a reasonable investment. The hybrid power system solution to electrify the selected area resulted in a least-cost combination of the hybrid power system that can meet the demand in a dependable manner at a cost about (0.321/kWh). If the wind resources in the study area at the lower stage, it's not economically viable for a wind turbine to generate the electricity.

  6. Energy performance analysis for a photovoltaic, diesel, battery hybrid power supply system

    CSIR Research Space (South Africa)

    Tazvinga, Henerica

    2010-03-01

    Full Text Available This paper looks at an energy performance analysis for a photovoltaic, diesel, and battery hybrid power supply system. The procedure starts by the identification of the hourly load requirements for a typical target consumer and the concept of load...

  7. Development of a new lower hybrid antenna module using a poloidal power divider

    Energy Technology Data Exchange (ETDEWEB)

    Maebara, S.; Imai, T.; Seki, M.; Suganuma, K. [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment; Goniche, M.; Bibet, Ph.; Berio, S.; Brossaud, J.; Rey, G.; Tonon, G. [Association Euratom-CEA, Centre d`Etudes de Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee

    1997-03-01

    A realistic antenna module using a poloidal divider for lower hybrid current drive (LHCD) experiment, is modelled and fabricated. In this antenna module test II, three types of poloidal dividers, which split the power in 3, are tested. (author). 15 refs.

  8. A Direct Power Conversion Topology for Grid Integration of Hybrid AC/DC Energy Resources

    DEFF Research Database (Denmark)

    Liu, Xiong; Loh, Poh Chiang; Wang, Peng;

    2013-01-01

    This paper proposes a multiple-input versatile matrix converter (VMC) for integrating hybrid ac/dc energy resources and storages to the power grid. The VMC is developed from the traditional indirect matrix converter but operates in the reverse-boost mode rather than in the forward-buck mode. The ...

  9. Flexible Microgrid Power Quality Enhancement Using Adaptive Hybrid Voltage and Current Controller

    DEFF Research Database (Denmark)

    He, Jinwei; Li, Yun Wei; Blaabjerg, Frede

    2014-01-01

    To accomplish superior harmonic compensation performance using distributed generation (DG) unit power electronics interfaces, an adaptive hybrid voltage and current controlled method (HCM) is proposed in this paper. It shows that the proposed adaptive HCM can reduce the numbers of low-pass/bandpa...

  10. Single-Phase Hybrid Switched Reluctance Motor for Low-Power Low-Cost Applications

    DEFF Research Database (Denmark)

    Lu, Kaiyuan; Rasmussen, Peter Omand; Jakobsen, Uffe

    2011-01-01

    This paper presents a new single-phase, Hybrid Switched Reluctance (HSR) motor for low-cost, low-power, pump or fan drive systems. Its single-phase configuration allows use of a simple converter to reduce the system cost. Cheap ferrite magnets are used and arranged in a special flux concentration...

  11. A comparison of GaAs and Si hybrid solar power systems

    Science.gov (United States)

    Heinbockel, J. H.; Roberts, A. S., Jr.

    1977-01-01

    Five different hybrid solar power systems using silicon solar cells to produce thermal and electric power are modeled and compared with a hybrid system using a GaAs cell. Among the indices determined are capital cost per unit electric power plus mechanical power, annual cost per unit electric energy, and annual cost per unit electric plus mechanical work. Current costs are taken to be $35,000/sq m for GaAs cells with an efficiency of 15% and $1000/sq m for Si cells with an efficiency of 10%. It is shown that hybrid systems can be competitive with existing methods of practical energy conversion. Limiting values for annual costs of Si and GaAs cells are calculated to be 10.3 cents/kWh and 6.8 cents/kWh, respectively. Results for both systems indicate that for a given flow rate there is an optimal operating condition for minimum cost photovoltaic output. For Si cell costs of $50/sq m optimal performance can be achieved at concentrations of about 10; for GaAs cells costing 1000/sq m, optimal performance can be obtained at concentrations of around 100. High concentration hybrid systems offer a distinct cost advantage over flat systems.

  12. A direct power conversion topology for grid integrations of hybrid AC/DC resources

    DEFF Research Database (Denmark)

    Liu, Xiong; Loh, Poh Chiang; Wang, Peng;

    2012-01-01

    This paper proposes a multiple-input versatile matrix converter (VMC) to integrate hybrid ac/dc energy resources and storages to a power grid. The VMC is developed based on the indirect matrix converter (IMC) with its six-switch voltage source converter replaced by a nine-switch topology. The nine...

  13. Method for Load Sharing and Power Management in a Hybrid PV/Battery Source Islanded Microgrid

    DEFF Research Database (Denmark)

    Karimi, Yaser; Oraee, Hashem; Guerrero, Josep M.

    2016-01-01

    This paper presents a decentralized load sharing and power management method for an islanded microgrid composed of PV units, battery units and hybrid PV/battery units. The proposed method performs all the necessary tasks such as load sharing among the units, battery charging and discharging and PV...

  14. COCO 3: hybrid power plant surpasses performance target

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-12-01

    Cogeneration company's third power plant at the Map Ta Phut industrial estate in Thailand is a coal fired circulating fluidized bed boiler linked in a unique steam cycle with the heat recovery units of two gas turbines. These HRUs function as both economiser and reheater. With nearly one year of operation behind it, performance has surpassed expectation for output, efficiency, and emission levels. 4 figs.

  15. Hybrid Voltage-Multipliers Based Switching Power Converters

    Science.gov (United States)

    Rosas-Caro, Julio C.; Mayo-Maldonado, Jonathan C.; Vazquez-Bautista, Rene Fabian; Valderrabano-Gonzalez, Antonio; Salas-Cabrera, Ruben; Valdez-Resendiz, Jesus Elias

    2011-08-01

    This work presents a derivation of PWM DC-DC hybrid converters by combining traditional converters with the Cockcroft-Walton voltage multiplier, the voltage multiplier of each converter is driven with the same transistor of the basic topology; this fact makes the structure of the new converters very simple and provides high-voltage gain. The traditional topologies discussed are the boost, buck-boost, Cuk and SEPIC. They main features of the discussed family are: (i) high-voltage gain without using extreme duty cycles or transformers, which allow high switching frequency and (ii) low voltage stress in switching devices, along with modular structures, and more output levels can be added without modifying the main circuit, which is highly desirable in some applications such as renewable energy generation systems. It is shown how a multiplier converter can become a generalized topology and how some of the traditional converters and several state-of-the-art converters can be derived from the generalized topologies and vice-versa. All the discussed converters were simulated, additionally experimental results are provided with an interleaved multiplier converter.

  16. Costa de Cocos wind-diesel hybrid power system

    Energy Technology Data Exchange (ETDEWEB)

    Ellis, Abraham; Estrada, Luis [Southwest Thechnology Development Institute, New Mexico State University, Las Cruces (United States); Newcomb, Charles; Corbus, David [National Renewable Energy Laboratory, CO (United States)

    2000-07-01

    This paper describes the performance and reliability of the Costa de Cocos wind-diesel hybrid system. Located in a remote coastal area in southern Mexico, the system is exposed to high temperatures and humidity, slat spray and occasional storm wind. It continues to supply the load, but has experienced some problems associated with inverter failure, battery degradation and corrosion. Inadequate operation and maintenance practices have also caused some problems. The information collected to date from technical visits and remote data collection is discussed in this paper. The system design and operation are also covered. [Spanish] Este articulo describe el rendimiento y la confiabilidad del sistema hibrido de viento y diesel en Costa de Cocos. Localizado en una costa remota en la parte sur de Mexico, el sistema esta expuesto a altas temperaturas y humedad, fuerte brisa marina y vientos ocasionales de tormenta. Sigue suministrando la carga, pero ha experimentado algunos problemas asociados con fallas del inversor, la degradacion de las baterias y corrosion. La inadecuada operacion y practicas de mantenimiento tambien han causado algunos problemas. Este articulo analiza la informacion reunida a la fecha sobre las visitas tecnicas y la recoleccion remota de datos. Tambien incluye el disel del sistema y su operacion.

  17. Simulation of the PEM fuel cell hybrid power train of an automated guided vehicle and comparison with experimental results

    NARCIS (Netherlands)

    Bram Veenhuizen; J.C.N. Bosma

    2009-01-01

    At HAN University research has been started into the development of a PEM fuel cell hybrid power train to be used in an automated guided vehicle. For this purpose a test facility is used with the possibility to test all important functional aspects of a PEM fuel cell hybrid power train. In this

  18. Simulation of the PEM fuel cell hybrid power train of an automated guided vehicle and comparison with experimental results

    NARCIS (Netherlands)

    Veenhuizen, Bram; Bosma, J.C.N.

    2009-01-01

    At HAN University research has been started into the development of a PEM fuel cell hybrid power train to be used in an automated guided vehicle. For this purpose a test facility is used with the possibility to test all important functional aspects of a PEM fuel cell hybrid power train. In this pape

  19. A Hybrid Estimator for Active/Reactive Power Control of Single-Phase Distributed Generation Systems with Energy Storage

    OpenAIRE

    Pahlevani, Majid; Eren, Suzan; Guerrero, Josep M.; Jain, Praveen

    2016-01-01

    This paper presents a new active/reactive power closed-loop control system for a hybrid renewable energy generation system used for single-phase residential/commercial applications.The proposed active/reactive control method includes a hybrid estimator, which is able to quickly and accurately estimate the active/reactive power values. The proposed control system enables the hybrid renewable energy generation system to be able to perform real-time grid interconnection services such as active v...

  20. Optimization-based power management of hybrid power systems with applications in advanced hybrid electric vehicles and wind farms with battery storage

    Science.gov (United States)

    Borhan, Hoseinali

    Modern hybrid electric vehicles and many stationary renewable power generation systems combine multiple power generating and energy storage devices to achieve an overall system-level efficiency and flexibility which is higher than their individual components. The power or energy management control, "brain" of these "hybrid" systems, determines adaptively and based on the power demand the power split between multiple subsystems and plays a critical role in overall system-level efficiency. This dissertation proposes that a receding horizon optimal control (aka Model Predictive Control) approach can be a natural and systematic framework for formulating this type of power management controls. More importantly the dissertation develops new results based on the classical theory of optimal control that allow solving the resulting optimal control problem in real-time, in spite of the complexities that arise due to several system nonlinearities and constraints. The dissertation focus is on two classes of hybrid systems: hybrid electric vehicles in the first part and wind farms with battery storage in the second part. The first part of the dissertation proposes and fully develops a real-time optimization-based power management strategy for hybrid electric vehicles. Current industry practice uses rule-based control techniques with "else-then-if" logic and look-up maps and tables in the power management of production hybrid vehicles. These algorithms are not guaranteed to result in the best possible fuel economy and there exists a gap between their performance and a minimum possible fuel economy benchmark. Furthermore, considerable time and effort are spent calibrating the control system in the vehicle development phase, and there is little flexibility in real-time handling of constraints and re-optimization of the system operation in the event of changing operating conditions and varying parameters. In addition, a proliferation of different powertrain configurations may

  1. Experimental Evaluation of Supercapacitor-Fuel Cell Hybrid Power Source for HY-IEL Scooter

    Directory of Open Access Journals (Sweden)

    Piotr Bujlo

    2013-01-01

    Full Text Available This paper presents the results of development of a hybrid fuel cell supercapacitor power system for vehicular applications that was developed and investigated at the Energy Sources Research Section of the Wroclaw Division of Electrotechnical Institute (IEL/OW. The hybrid power source consists of a polymer exchange membrane fuel cell (PEMFC stack and an energy-type supercapacitor that supports the system in time of peak power demands. The developed system was installed in the HY-IEL electric scooter. The vehicle was equipped with auxiliary components (e.g., air compressor, hydrogen tank, and electromagnetic valves needed for proper operation of the fuel cell stack, as well as electronic control circuits and a data storage unit that enabled on-line recording of system and vehicle operation parameters. Attention is focused on the system energy flow monitoring. The experimental part includes field test results of a vehicle powered with the fuel cell-supercapacitor system. Values of currents and voltages recorded for the system, as well as the vehicle’s velocity and hydrogen consumption rate, are presented versus time of the experiment. Operation of the hybrid power system is discussed and analysed based on the results of measurements obtained.

  2. Performance evaluation of hybrid VLC using device cost and power over data throughput criteria

    Science.gov (United States)

    Lee, C. C.; Tan, C. S.; Wong, H. Y.; Yahya, M. B.

    2013-09-01

    Visible light communication (VLC) technology has attained its attention in both academic and industry lately. It is determined by the development of light emitting diode (LED) technology for solid-state lighting (SSL).It has great potential to gradually replace radio frequency (RF) wireless technology because it offers unregulated and unlicensed bandwidth to withstand future demand of indoor wireless access to real-time bandwidth-demanding applications. However, it was found to provide intrusive uplink channel that give rise to unpleasant irradiance from the user device which could interfere with the downlink channel of VLC and hence limit mobility to users as a result of small coverage (field of view of VLC).To address this potential problem, a Hybrid VLC system which integrates VLC (for downlink) and RF (for uplink) technology is proposed. It offers a non-intrusive RF back channel that provides high throughput VLC and maintains durability with conventional RF devices. To deploy Hybrid VLC system in the market, it must be energy and cost saving to attain its equivalent economical advantage by comparing to existing architecture that employs fluorescent or LED lights with RF technology. In this paper, performance evaluation on the proposed hybrid system was carried out in terms of device cost and power consumption against data throughput. Based on our simulation, Hybrid VLC system was found to reduce device cost by 3% and power consumption by 68% when compares to fluorescent lights with RF technology. Nevertheless, when it is compared to LED lights with RF technology, our proposed hybrid system is found to achieve device cost saving as high as 47% and reduced power consumption by 49%. Such promising results have demonstrated that Hybrid VLC system is a feasible solution and has paved the way for greater cost saving and energy efficient compares with the current RF architecture even with the increasing requirement of indoor area coverage.

  3. Potential of hybrid geothermal/coal fired power plants in Arizona

    Energy Technology Data Exchange (ETDEWEB)

    White, D.H.; Goldstone, L.A.

    1982-08-01

    The City of Burbank and the Ralph M. Parsons Company studies showed several advantages for hybrid geothermal/coal fired power plants, as follows: (1) the estimated cost of producing electricity in hybrid plant is about 18.3 mills/kWh, compared to 19.3 mills/kWh in an all-coal fired power plant; (2) the coal requirements for a given plant can be reduced about 12 to 17%; and (3) the geothermal brines can be used for power plant cooling water, and in some cases, as boiler feedwater. The pertinent results of the City of Burbank studies are summarized and applied to the geothermal and coal resources of Arizona for possible future utilization.

  4. Design and modeling of power system for a fuel cell hybrid switcher locomotive

    Energy Technology Data Exchange (ETDEWEB)

    Guo Liping, E-mail: lguo@niu.ed [Department of Engineering Technology, Northern Illinois University, DeKalb, IL 60115 (United States); Yedavalli, Karthik; Zinger, Donald [Department of Electrical Engineering, Northern Illinois University, DeKalb, IL 60115 (United States)

    2011-02-15

    This paper discusses the design and modeling of power system for a fuel cell hybrid locomotive. Different types of fuel cells for appropriate application to locomotives were compared, fuel cell and auxiliary storage devices were modeled, and a control strategy for the overall system was developed in this paper. By using the proposed control strategy, the power control system regulates the sharing of power demand between fuel cell and auxiliary storage units including batteries and ultracapacitors. Experimental data of the power duty cycle of a typical switcher locomotive is analyzed. The proposed control system is tested using the experimental data. Results show that the control system is able to maintain output voltage from different power sources within a certain range, keep the state of charge of the batteries within an optimal range and meet power demand of the locomotive at a high efficiency.

  5. Design and modeling of power system for a fuel cell hybrid switcher locomotive

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Liping [Department of Engineering Technology, Northern Illinois University, DeKalb, IL 60115 (United States); Yedavalli, Karthik; Zinger, Donald [Department of Electrical Engineering, Northern Illinois University, DeKalb, IL 60115 (United States)

    2011-02-15

    This paper discusses the design and modeling of power system for a fuel cell hybrid locomotive. Different types of fuel cells for appropriate application to locomotives were compared, fuel cell and auxiliary storage devices were modeled, and a control strategy for the overall system was developed in this paper. By using the proposed control strategy, the power control system regulates the sharing of power demand between fuel cell and auxiliary storage units including batteries and ultracapacitors. Experimental data of the power duty cycle of a typical switcher locomotive is analyzed. The proposed control system is tested using the experimental data. Results show that the control system is able to maintain output voltage from different power sources within a certain range, keep the state of charge of the batteries within an optimal range and meet power demand of the locomotive at a high efficiency. (author)

  6. Wind Power Forecasting techniques in complex terrain: ANN vs. ANN-CFD hybrid approach

    Science.gov (United States)

    Castellani, Francesco; Astolfi, Davide; Mana, Matteo; Burlando, Massimiliano; Meißner, Cathérine; Piccioni, Emanuele

    2016-09-01

    Due to technology developments, renewable energies are becoming competitive against fossil sources and the number of wind farms is growing, which have to be integrated into power grids. Therefore, accurate power forecast is needed and often operators are charged with penalties in case of imbalance. Yet, wind is a stochastic and very local phenomenon, and therefore hard to predict. It has a high variability in space and time and wind power forecast is challenging. Statistical methods, as Artificial Neural Networks (ANN), are often employed for power forecasting, but they have some shortcomings: they require data sets over several years and are not able to capture tails of wind power distributions. In this work a pure ANN power forecast is compared against a hybrid method, based on the combination of ANN and a physical method using computational fluid dynamics (CFD). The validation case is a wind farm sited in southern Italy in a very complex terrain, with a wide spread turbine layout.

  7. Intelligent Hybrid Vehicle Power Control - Part 1: Machine Learning of Optimal Vehicle Power

    Science.gov (United States)

    2012-06-30

    secondary power source, an HEV uses a smaller and more efficient engine in its drivetrain . Because of the dual-power-source nature, the design and...the motor or both can provide the traction power to the drivetrain . During vehicle deceleration, the regenerative braking power is captured to charge...is generated for each time step t as a function of Pbatt(t) and ωeng(t) for the given drivetrain power Pdrive-sh(t), and the electric load power

  8. Ultra-Low-Power Hybrid Light-Matter Solitons

    CERN Document Server

    Tinkler, L; Skryabin, D V; Yulin, A; Royall, B; Farrer, I; Ritchie, D A; Krizhanovskii, D N; Skolnick, M S

    2014-01-01

    New functionalities in nonlinear optics will require systems with giant optical nonlinearity as well as compatibility with photonic circuit fabrication techniques. Here we introduce a new platform based on strong light-matter coupling between waveguide photons and quantum-well excitons. On a sub-millimeter length scale we generate sub-picosecond bright temporal solitons at a pulse energy of only 0.5 pico-Joules. From this we deduce an unprecedented nonlinear refractive index 3 orders of magnitude larger than in any other ultrafast system. We study both temporal and spatio-temporal nonlinear effects and for the first time observe dark-bright spatio-temporal solitons. Theoretical modelling of soliton formation in the strongly coupled system confirms the experimental observations. These results show the promise of our system as a high speed, low power, integrated platform for physics and devices based on strong interactions between photons.

  9. Hybrid Cooling for Geothermal Power Plants: Final ARRA Project Report

    Energy Technology Data Exchange (ETDEWEB)

    Bharathan, D.

    2013-06-01

    Many binary-cycle geothermal plants use air as the heat rejection medium. Usually this is accomplished by using an air-cooled condenser (ACC) system to condense the vapor of the working fluid in the cycle. Many air-cooled plants suffer a loss of production capacity of up to 50% during times of high ambient temperatures. Use of limited amounts of water to supplement the performance of ACCs is investigated. Deluge cooling is found to be one of the least-cost options. Limiting the use of water in such an application to less than one thousand operating hours per year can boost plant output during critical high-demand periods while minimizing water use in binary-cycle geothermal power plants.

  10. Efficient Hybrid Optimal Design Method for Power Electronics Converters

    CERN Document Server

    AUTHOR|(SzGeCERN)697719; Aguglia, Davide; Viarouge, Philippe; Cros, Jérôme

    2015-01-01

    This paper presents a novel design methodology for dimensioning optimal power-electronic converters, which is able to achieve the precision of numerical simulation-based optimization procedures, however minimizing the overall computation time. The approach is based on the utilization of analytical and frequency-domain design models for a numerical optimization process, a validation with numerical simulations of the intermediate optimal solutions, and the correction of the analytical design models precision from the numerical simulation results. This method allows using the numerical simulation in an efficient way, where typically less than ten correction iterations are required. In order to demonstrate the performances of the proposed methodology, the calculation of the control parameters for an H-bridge DC-DC converter and the optimal dimensioning of a damped output filter for a buck converter using the proposed approach is presented.

  11. The economics of hybrid power systems for sustainable desert agriculture in Egypt

    DEFF Research Database (Denmark)

    Kamel, S.M.; Dahl, C.

    2005-01-01

    Egypt has embarked on an ambitious desert land reclamation program in order to increase total food production. Energy planners for these desert agriculture locations have chosen diesel generation power technology because minimization of the initial capital cost of a power supply system is their top...... to investigate the economic potential of such systems in Egypt’s desert agriculture sector. Using optimization software, we assess the economics of hybrid power systems versus the present diesel generation technology in a remote agricultural development area. We also consider the emission reduction advantages...

  12. Effect of buoyancy and power design parameters on hybrid airship performance

    Science.gov (United States)

    Talbot, P. D.; Gelhausen, P. A.

    1983-01-01

    The effects of several design parameters on the performance of hybrid airships having rotors and propellers were examined with a simple mathematical model. The parameters included buoyancy ratio, Froude number, ratio of rotor power to total power, and rotor shaft tilt. Performance variations resulting from changes in these parameters were calculated, and are presented and discussed. Performance quantities included best climb rate, equivalent vehicle L/D, and maximum speed. Performance at all speeds between hover and maximum speed was found to be sensitive to power distribution between rotors and propellers, and to rotor shaft tilt.

  13. Control of Hybrid System Using Multi-Input Inverter and Maximum Power Point Tracking

    Directory of Open Access Journals (Sweden)

    N.Sivakumar

    2013-07-01

    Full Text Available The objective of this paper is to control the Wind/PV hybrid system using Multi-input inverter to get constant output power for different operating conditions. The MPPT also used in this system to get the maximum peak power to the load. The perturbation observation (P&O method is used to accomplish the maximum power point tracking algorithm for input sources. The operating principle of the open loop and closed loop circuit of multi-input inverter is discussed.

  14. Modeling and Nonlinear Control of Electric Power Stage in Hybrid Electric Vehicle

    DEFF Research Database (Denmark)

    Tahri, A.; El Fadil, H.; Guerrero, Josep M.;

    2014-01-01

    This paper deals with the problem of modeling and controlling the electric power stage of hybrid electric vehicle. The controlled system consists of a fuel cell (FC) as a main source, a supercapacitor as an auxiliary source, two DC-DC power converters, an inverter and a traction induction motor...... based approach is used to control the DC/DC power converters associated with the DC sources, the backstepping technique combined with the field oriented control strategy are invoked in order to control the induction motor. It is formally shown, using a theoretical analysis and simulation results...

  15. Optimization of hybrid power system composed of SMES and flywheel MG for large pulsed load

    Science.gov (United States)

    Niiyama, K.; Yagai, T.; Tsuda, M.; Hamajima, T.

    2008-09-01

    A superconducting magnetic storage system (SMES) has some advantages such as rapid large power response and high storage efficiency which are superior to other energy storage systems. A flywheel motor generator (FWMG) has large scaled capacity and high reliability, and hence is broadly utilized for a large pulsed load, while it has comparatively low storage efficiency due to high mechanical loss compared with SMES. A fusion power plant such as International Thermo-Nuclear Experimental Reactor (ITER) requires a large and long pulsed load which causes a frequency deviation in a utility power system. In order to keep the frequency within an allowable deviation, we propose a hybrid power system for the pulsed load, which equips the SMES and the FWMG with the utility power system. We evaluate installation cost and frequency control performance of three power systems combined with energy storage devices; (i) SMES with the utility power, (ii) FWMG with the utility power, (iii) both SMES and FWMG with the utility power. The first power system has excellent frequency power control performance but its installation cost is high. The second system has inferior frequency control performance but its installation cost is the lowest. The third system has good frequency control performance and its installation cost is attained lower than the first power system by adjusting the ratio between SMES and FWMG.

  16. Hybrid PID and PSO-based control for electric power assist steering system for electric vehicle

    Science.gov (United States)

    Hanifah, R. A.; Toha, S. F.; Ahmad, S.

    2013-12-01

    Electric power assist steering (EPAS) system provides an important significance in enhancing the driving performance of a vehicle with its energy-conserving features. This paper presents a hybrid PID (Proportional-Integral-Derivative) and particle swarm optimization (PSO) based control scheme to minimize energy consumption for EPAS. This single objective optimization scheme is realized using the PSO technique in searching for best gain parameters of the PID controller. The fast tuning feature of this optimum PID controller produced high-quality solutions. Simulation results show the performance and effectiveness of the hybrid PSO-PID based controller as opposed to the conventional PID controller.

  17. LQR-Based Power Train Control Method Design for Fuel Cell Hybrid Vehicle

    Directory of Open Access Journals (Sweden)

    Yun Haitao

    2013-01-01

    Full Text Available Based on the mathematical model of fuel cell hybrid vehicle (FCHV proposed in our previous study, a multistate feedback control strategy of the hybrid power train is designed based on the linear quadratic regulator (LQR algorithm. A Kalman Filter (KF observer is introduced to estimate state of charge (SOC of the battery firstly, and then a linear quadratic regulator is constructed to compute the state feedback gain matrix of the closed-loop control system. At last, simulation and actual test are utilized to demonstrate this new approach.

  18. Design and Comparison of Power Systems for a Fuel Cell Hybrid Electric Vehicle

    DEFF Research Database (Denmark)

    Schaltz, Erik; Rasmussen, Peter Omand

    2008-01-01

    In a fuel cell hybrid electric vehicle (FCHEV) the fuel cell stack is assisted by one or more energy storage devices. Thereby the system cost, mass, and volume can be decreased, and a significant better performance can be obtained. Two often used energy storage devices are the battery...... ultracapacitors are the only energy storage device the system becomes too big and heavy. A fuel cell/battery/ultracapacitor hybrid provides the longest life time of the batteries. If the fuel cell stack power is too small, the system will be big, heavy, and have a poor efficiency....

  19. Analysis of the Fuel Efficiency of a Hybrid Electric Drive with an Electric Power Splitter

    Directory of Open Access Journals (Sweden)

    D. Čundev

    2008-01-01

    Full Text Available This paper presents the results of an analysis of the fuel efficiency of a hybrid electric car drive, with an electric power splitter based on a double rotor synchronous permanent magnet generator. The results have been obtained through a precisely determined mathematical model and by simulating the characteristics of all essential values for the entire drive. This work is related to the experimental working stand for electric and hybrid car drive research, which has been developed at the Faculty of Electrical Engineering (FEE at CTU in Prague. 

  20. Identification of environmental issues: Hybrid wood-geothermal power plant, Wendel-Amedee KGRA, Lassen County, California: First phase report

    Energy Technology Data Exchange (ETDEWEB)

    1981-08-14

    The development of a 55 MWe power plant in Lassen County, California, has been proposed. The proposed power plant is unique in that it will utilize goethermal heat and wood fuel to generate electrical power. This report identifies environmental issues and constraints which may impact the proposed hybrid wood-geothermal power plant. (ACR)

  1. Fresnel-collectors in hybrid solar thermal power plants with high solar shares

    Energy Technology Data Exchange (ETDEWEB)

    Lerchenmueller, H.; Mertins, M.; Morin, G. [Fraunhofer Inst. for Solar Energy Systems, Freiburg (Germany); Haeberle, A. [PSE GmbH, Solar Info Center, Freiburg (Germany); Bockamp, S.; Ewert, M.; Fruth, M.; Griestop, T. [E.ON Energie AG, Muenchen (Germany); Dersch, J. [Deutsches Zentrum fuer Luft- und Raumfahrt, Koeln (Germany)

    2004-07-01

    The use of Fresnel-Collectors in power plant configurations with low or zero CO2-emission has been analysed in this paper. Both, the solar-biomass hybrid plant and the solar-gas hybrid plant are very promising concepts with respect to technical, economical and ecological aspects. The hybrid operation would be very useful to handle the fluctuating solar resource and facilitate operation. Depending on feed in tariffs the hybridisation of a solar thermal power plant with biomass or with small shares of natural gas can be economically very interesting. The ecological advantage of a solar-biomass power plant is evident, since it would be a zero CO2- emission plant. Beyond that biomass is a limited source, especially in regions with high solar irradiance. The herein examined gas hybrid variants are by far more favourable than Integrated Solar Combined Cycle Systems (ISCCS), which have been previously examined. Since much higher solar shares can be reached this is a forward-looking technology. Furthermore the solar field does not act as a disturbing factor as opposed to the ISCCS concept, where the efficiency of the sophisticated CC system is reduced due to suboptimal dimensioning of components. In other words: It is better to build the suggested hybrid plant with low gas share and CC plants instead of ISCCS plants. The resulting solar levelised electricity costs of both options are approximately the same. The calculated levelised electricity costs for the examined configurations of between 11 and 13 ct/kWh are very promising results. The calculations were made based on cost assumptions for the collector of 130 Euro/m{sup 2} which seems realistic not for the first project but for the third plant. As a next step in the commercialisation of the Fresnel-technology demonstration and test collectors must be built, such as by the Australian company Solar Heat and Power, to validate the technical and economic assumptions. (orig.)

  2. The Villas Carrousel PV-Wind Hybrid Project

    Energy Technology Data Exchange (ETDEWEB)

    Huacuz, Jorge M. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    A pilot project was carried out to supply electrical services for an ecological hotel (eco-hotel), using solar and wind energy in Southeast Mexico. Fifteen small photovoltaic-wind hybrid systems were designed and built by researchers of the Electrical Research Institute of Mexico (IIE), as part of a cooperation agreement with the mexican company Carrousel Operadora Turistica, aimed at developing a technology package to supply electrical services to similar hotels sited in remote areas. Each hybrid system includes one wind generator of 500W nominal capacity, one PV panel ranging in power from 150W to 320 Watts peak, one lead-acid battery bank of 570 ampere-hour in capacity, and an electronic charge controller. This paper describes the systems and summarizes the results from the first twelve months of operation. [Espanol] Se llevo a cabo un proyecto piloto para el suministro de servicios electricos a un hotel ecologico (eco-hotel), utilizando energia solar y energia del viento en el Sudeste de Mexico. Investigadores del Instituto de Investigaciones Electricas de Mexico, disenaron y construyeron quince pequenos sistemas hibridos fotovoltaicos-viento, como parte de un acuerdo de cooperacion con la compania mexicana Carrousel Operadora Turistica, orientado al desarrollo de un paquete tecnologico para proporcionar servicios de energia electrica a hoteles similares ubicados en areas remotas. Cada sistema hibrido incluye un aero-generador con capacidad nominal de 500W un panel foto-voltaico con una potencia que varia entre los 150W y los 320W pico, una banco de baterias de plomo-acido de 570 amperes-hora de capacidad y un controlador electronico de carga. Este articulo describe los sistemas y presenta un resumen de los resultados de los primeros doce meses de operacion.

  3. Techno-economic Analysis of a Wind-Diesel Hybrid Power System in the South Algeria

    Directory of Open Access Journals (Sweden)

    Khaireddine Allali

    2015-07-01

    Full Text Available The electrical energy is often produced with the help of diesel generators in isolated areas in the Saharan region. While the latter requiring relatively little investment because is generally expensive to exploit due to the transportation to remote areas adds extra cost, significant fuel consumption and relatively high maintenance cost, etc. Moreover, the electricity production by the diesel is ineffective, presents significant environmental risks. But these isolated areas have significant wind energy potential; which is good position for the exploitation of clean and sustainable wind energy. The use of wind-diesel power system is widely recommended especially to reduce fuel consumption and in this way to reduce system operating costs and environmental impact. The subject of this paper is to present the techno-economic analysis of a wind-diesel hybrid power system. In this context, the contribution envisaged with this research is to collaborate on the optimal design of a hybrid power system including a wind turbine generator, a diesel generator and an energy storage system for powering a continuous way an isolated site in the South Algerian installed power of 120 kW.This system has a high control strategy for the management of different power sources (wind, diesel, battery that depending to weather conditions, especially wind speed values and the power demanded by the consumer load.

  4. Hybrid power system intelligent operation and protection involving distributed architectures and pulsed loads

    Science.gov (United States)

    Mohamed, Ahmed

    Efficient and reliable techniques for power delivery and utilization are needed to account for the increased penetration of renewable energy sources in electric power systems. Such methods are also required for current and future demands of plug-in electric vehicles and high-power electronic loads. Distributed control and optimal power network architectures will lead to viable solutions to the energy management issue with high level of reliability and security. This dissertation is aimed at developing and verifying new techniques for distributed control by deploying DC microgrids, involving distributed renewable generation and energy storage, through the operating AC power system. To achieve the findings of this dissertation, an energy system architecture was developed involving AC and DC networks, both with distributed generations and demands. The various components of the DC microgrid were designed and built including DC-DC converters, voltage source inverters (VSI) and AC-DC rectifiers featuring novel designs developed by the candidate. New control techniques were developed and implemented to maximize the operating range of the power conditioning units used for integrating renewable energy into the DC bus. The control and operation of the DC microgrids in the hybrid AC/DC system involve intelligent energy management. Real-time energy management algorithms were developed and experimentally verified. These algorithms are based on intelligent decision-making elements along with an optimization process. This was aimed at enhancing the overall performance of the power system and mitigating the effect of heavy non-linear loads with variable intensity and duration. The developed algorithms were also used for managing the charging/discharging process of plug-in electric vehicle emulators. The protection of the proposed hybrid AC/DC power system was studied. Fault analysis and protection scheme and coordination, in addition to ideas on how to retrofit currently available

  5. Hybrid Systems of Distributed Generation with Renewable Sources: Modeling and Analysis of Their Operational Modes in Electric Power System

    Directory of Open Access Journals (Sweden)

    A. Gashimov

    2013-01-01

    Full Text Available The paper considers problems pertaining to modeling and simulation of operational hybrid system modes of the distributed generation comprising conventional sources – modular diesel generators, gas-turbine power units; and renewable sources – wind and solar power plants. Operational modes of the hybrid system have been investigated under conditions of electrical connection with electric power system and in case of its isolated operation. As a consequence

  6. Investigation of Control Algorithms for Tracked Vehicle Mobility Load Emulation for a Combat Hybrid Electric Power System

    Science.gov (United States)

    2009-07-30

    Investigation of Control Algorithms for Tracked Vehicle Mobility Load Emulation for a Combat Hybrid Electric Power System Jarrett Goodell and...TITLE AND SUBTITLE Investigation of Control Algorithms for Tracked Vehicle Mobility Load Emulation for a Combat Hybrid Electric Power System 5a...for ~ 22 ton tracked vehicle • Tested and Developed: – Motors, Generators, Batteries, Inverters, DC-DC Converters , Thermal Management, Pulse Power

  7. Analysis of a model of fuel cell - gas turbine hybrid power system for enhanced energy efficiency

    Science.gov (United States)

    Calay, Rajnish K.; Mustafa, Mohamad Y.; Virk, Mohammad S.; Mustafa, Mahmoud F.

    2012-11-01

    A simple mathematical model to evaluate the performance of FC-GT hybrid system is presented in this paper. The model is used to analyse the influence of various parameters on the performance of a typical hybrid system, where excess heat rejected from the solid-oxide fuel cell stack is utilised to generate additional power through a gas turbine system and to provide heat energy for space heating. The model is based on thermodynamic analysis of various components of the plant and can be adapted for various configurations of the plant components. Because there are many parameters defining the efficiency and work output of the hybrid system, the technique is based on mathematical and graphical optimisation of various parameters; to obtain the maximum efficiency for a given plant configuration.

  8. Characterization of hybrid self-powered neutron detector under neutron irradiation

    CERN Document Server

    Nakamichi, M; Yamamura, C; Nakazawa, M; Kawamura, H

    2000-01-01

    To evaluate the irradiation behaviour of a blanket mock-up on in-pile functional test, it is necessary to measure the neutron flux change in the in-pile mock-up by a neutron detector, such as the self-powered neutron detector (SPND). With its small-sized emitter, which has high sensitivity and fast response time, SPND is an indispensable tool in order to measure the local neutron flux change. In the case of an in-pile functional test, it is necessary that response time is less than 1s and ratio of SPND output current is more than 0.3 of output current of SPND with Rh emitter. Therefore, a hybrid SPND with high sensitivity and fast response time was developed. This hybrid SPND used a hybrid emitter, i.e. Co cladded Pt-13%Rh.

  9. Large-scale multi-zone optimal power dispatch using hybrid hierarchical evolution technique

    Directory of Open Access Journals (Sweden)

    Manjaree Pandit

    2014-03-01

    Full Text Available A new hybrid technique based on hierarchical evolution is proposed for large, non-convex, multi-zone economic dispatch (MZED problems considering all practical constraints. Evolutionary/swarm intelligence-based optimisation techniques are reported to be effective only for small/medium-sized power systems. The proposed hybrid hierarchical evolution (HHE algorithm is specifically developed for solving large systems. The HHE integrates the exploration and exploitation capabilities of particle swarm optimisation and differential evolution in a novel manner such that the search efficiency is improved substantially. Most hybrid techniques export or exchange features or operations from one algorithm to the other, but in HHE their entire individual features are retained. The effectiveness of the proposed algorithm has been verified on six-test systems having different sizes and complexity levels. Non-convex MZED solution for such large and complex systems has not yet been reported.

  10. Fractional order fuzzy control of hybrid power system with renewable generation using chaotic PSO.

    Science.gov (United States)

    Pan, Indranil; Das, Saptarshi

    2016-05-01

    This paper investigates the operation of a hybrid power system through a novel fuzzy control scheme. The hybrid power system employs various autonomous generation systems like wind turbine, solar photovoltaic, diesel engine, fuel-cell, aqua electrolyzer etc. Other energy storage devices like the battery, flywheel and ultra-capacitor are also present in the network. A novel fractional order (FO) fuzzy control scheme is employed and its parameters are tuned with a particle swarm optimization (PSO) algorithm augmented with two chaotic maps for achieving an improved performance. This FO fuzzy controller shows better performance over the classical PID, and the integer order fuzzy PID controller in both linear and nonlinear operating regimes. The FO fuzzy controller also shows stronger robustness properties against system parameter variation and rate constraint nonlinearity, than that with the other controller structures. The robustness is a highly desirable property in such a scenario since many components of the hybrid power system may be switched on/off or may run at lower/higher power output, at different time instants.

  11. Hybridized Electromagnetic-Triboelectric Nanogenerator for a Self-Powered Electronic Watch.

    Science.gov (United States)

    Quan, Ting; Wang, Xue; Wang, Zhong Lin; Yang, Ya

    2015-12-22

    We report a hybridized nanogenerator including a triboelectric nanogenerator (TENG) and six electromagnetic generators (EMGs) that can effectively scavenge biomechanical energy for sustainably powering an electronic watch. Triggered by the natural motions of the wearer's wrist, a magnetic ball at the center in an acrylic box with coils on each side will collide with the walls, resulting in outputs from both the EMGs and the TENG. By using the hybridized nanogenerator to harvest the biomechanical energy, the electronic watch can be continuously powered under different motion types of the wearer's wrist, where the best approach is to charge a 100 μF capacitor in 39 s to maintain the continuous operation of the watch for 456 s. To increase the working time of the watch further, a homemade Li-ion battery has been utilized as the energy storage unit for realizing the continuous working of the watch for about 218 min by using the hybridized nanogenerator to charge the battery within 32 min. This work will provide the opportunities for developing a nanogenerator-based built-in power source for self-powered wearable electronics such as an electronic watch.

  12. Solar Central Receiver Hybrid Power Systems sodium-cooled receiver concept. Final report. Volume III. Appendices

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-01-01

    The overall, long term objective of the Solar Central Receiver Hybrid Power System is to identify, characterize, and ultimately demonstrate the viability and cost effectiveness of solar/fossil, steam Rankine cycle, hybrid power systems that: (1) consist of a combined solar central receiver energy source and a nonsolar energy source at a single, common site, (2) may operate in the base, intermediate, and peaking capacity modes, (3) produce the rated output independent of variations in solar insolation, (4) provide a significant savings (50% or more) in fuel consumpton, and (5) produce power at the minimum possible cost in mills/kWh. It is essential that these hybrid concepts be technically feasible and economically competitive with other systems in the near to mid-term time period (1985-1990) on a commercial scale. The program objective for Phase I is to identify and conceptually characterize solar/fossil steam Rankine cycle, commercial-scale, power plant systems that are economically viable and technically feasible. This volume contains appendices to the conceptual design and systems analysis studies gien in Volume II, Books 1 and 2. (WHK)

  13. Shunt hybrid active power filter for harmonic mitigation: A practical design approach

    Indian Academy of Sciences (India)

    Unnikrishnan A K; Chandira Sekaran E; Subhash Joshi T G; Manju A S; Aby Joseph

    2015-06-01

    The increasing importance of Power Quality problems has been responsible for several improvements in Active Power Filter (APF) typologies in the last decade. The increased cost and switching losses make a pure shunt APF economically impractical for high power applications. In higher power levels shunt Hybrid Active Power Filter (HAPF) has been reported to be a useful approach to eliminate current harmonics caused by nonlinear loads. This paper presents a control strategy and design criteria for transformer-less shunt HAPF with special attention to the integration of series passive filter. The paper also compares the performance improvement of passive harmonic filter when modified as shunt HAPF. Experimental results obtained verify the viability and effectiveness of the proposed design criteria and control algorithm.

  14. Online Identification of Power Required for Self-Sustainability of the Battery in Hybrid Electric Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Malikopoulos, Andreas [ORNL

    2014-01-01

    Hybrid electric vehicles have shown great potential for enhancing fuel economy and reducing emissions. Deriving a power management control policy to distribute the power demanded by the driver optimally to the available subsystems (e.g., the internal combustion engine, motor, generator, and battery) has been a challenging control problem. One of the main aspects of the power management control algorithms is concerned with the self-sustainability of the electrical path, which must be guaranteed for the entire driving cycle. This paper considers the problem of identifying online the power required by the battery to maintain the state of charge within a range of the target value. An algorithm is presented that realizes how much power the engine needs to provide to the battery so that self-sustainability of the electrical path is maintained.

  15. Plasma characteristics in inductively and capacitively coupled hybrid source using single RF power

    Science.gov (United States)

    Kim, Kwan-Yong; Lee, Moo-Young; Kim, Tae-Woo; Kim, Ju-Ho; Chung, Chin-Wook

    2016-09-01

    Parallel combined inductively coupled plasma (ICP) and capacitively coupled plasma (CCP) using single RF generator was proposed to linear control of the plasma density with RF power. In the case of ICP, linear control of the plasma density is difficult because there is a density jump up due to E to H transition. Although the plasma density of CCP changes linearly with power, the density is lower than that of ICP due to high ion energy loss at the substrate. In our hybrid source, the single RF power generator was connected to electrode and antenna, and the variable capacitor was installed between the antenna and the power generator to control the current flowing through the antenna and the electrode. By adjusting the current ratio between the antenna and the electrode, linear characteristic of plasma density with RF power is achieved.

  16. Research on Hybrid Power System with Dual Stator-winding and Its Decoupled Control Strategy

    Institute of Scientific and Technical Information of China (English)

    WEI Shu-guang; MA Xiao-jun; KE Rong-shuo; LIU Qiu-li

    2012-01-01

    For the bi-power system adopted widely in future armored vehicles,a hybrid power generator with dual stator-winding was proposed.Its structure and working principle were analyzed first,and its main parameters were determined and verified according to the power requirements.The system's mathematical model was established,and a decoupled control method was put forward on the basis of the instantaneous reactive power theory.For the voltage building-up,a voltage control strategy was designed on the basis of mixed reactive power compensation to implement stabilized 28V and 270V outputs simultaneously.The simulation results show that the stabilization accuracy and disturbance rejection ability of the system are improved much more than other ordinary generators.

  17. Modified Grid-Connected CSI for Hybrid PV/Wind Power Generation System

    Directory of Open Access Journals (Sweden)

    D. Amorndechaphon

    2012-01-01

    Full Text Available The principle of a power conditioning unit for hybrid PV/wind power generation system is proposed. The proposed power conditioner is based on the current source inverter (CSI topology. All energy sources are connected in parallel with a DC-bus through the modified wave-shaping circuits. To achieve the unity power factor at the utility grid, the DC-link current can be controlled via the wave-shaping circuits with the sinusoidal PWM scheme. In this work, the carrier-based PWM scheme is also proposed to minimize the utility current THD. The power rating of the proposed system can be increased by connecting more PV/wind modules through their wave-shaping circuits in parallel with the other modules. The details of the operating principles, the system configurations, and the design considerations are described. The effectiveness of the proposed CSI is demonstrated by simulation results.

  18. A Hybrid Maximum Power Point Tracking Method for Automobile Exhaust Thermoelectric Generator

    Science.gov (United States)

    Quan, Rui; Zhou, Wei; Yang, Guangyou; Quan, Shuhai

    2016-08-01

    To make full use of the maximum output power of automobile exhaust thermoelectric generator (AETEG) based on Bi2Te3 thermoelectric modules (TEMs), taking into account the advantages and disadvantages of existing maximum power point tracking methods, and according to the output characteristics of TEMs, a hybrid maximum power point tracking method combining perturb and observe (P&O) algorithm, quadratic interpolation and constant voltage tracking method was put forward in this paper. Firstly, it searched the maximum power point with P&O algorithms and a quadratic interpolation method, then, it forced the AETEG to work at its maximum power point with constant voltage tracking. A synchronous buck converter and controller were implemented in the electric bus of the AETEG applied in a military sports utility vehicle, and the whole system was modeled and simulated with a MATLAB/Simulink environment. Simulation results demonstrate that the maximum output power of the AETEG based on the proposed hybrid method is increased by about 3.0% and 3.7% compared with that using only the P&O algorithm and the quadratic interpolation method, respectively. The shorter tracking time is only 1.4 s, which is reduced by half compared with that of the P&O algorithm and quadratic interpolation method, respectively. The experimental results demonstrate that the tracked maximum power is approximately equal to the real value using the proposed hybrid method,and it can preferentially deal with the voltage fluctuation of the AETEG with only P&O algorithm, and resolve the issue that its working point can barely be adjusted only with constant voltage tracking when the operation conditions change.

  19. Subsurface Hybrid Power Options for Oil & Gas Production at Deep Ocean Sites

    Energy Technology Data Exchange (ETDEWEB)

    Farmer, J C; Haut, R; Jahn, G; Goldman, J; Colvin, J; Karpinski, A; Dobley, A; Halfinger, J; Nagley, S; Wolf, K; Shapiro, A; Doucette, P; Hansen, P; Oke, A; Compton, D; Cobb, M; Kopps, R; Chitwood, J; Spence, W; Remacle, P; Noel, C; Vicic, J; Dee, R

    2010-02-19

    An investment in deep-sea (deep-ocean) hybrid power systems may enable certain off-shore oil and gas exploration and production. Advanced deep-ocean drilling and production operations, locally powered, may provide commercial access to oil and gas reserves otherwise inaccessible. Further, subsea generation of electrical power has the potential of featuring a low carbon output resulting in improved environmental conditions. Such technology therefore, enhances the energy security of the United States in a green and environmentally friendly manner. The objective of this study is to evaluate alternatives and recommend equipment to develop into hybrid energy conversion and storage systems for deep ocean operations. Such power systems will be located on the ocean floor and will be used to power offshore oil and gas exploration and production operations. Such power systems will be located on the oceans floor, and will be used to supply oil and gas exploration activities, as well as drilling operations required to harvest petroleum reserves. The following conceptual hybrid systems have been identified as candidates for powering sub-surface oil and gas production operations: (1) PWR = Pressurized-Water Nuclear Reactor + Lead-Acid Battery; (2) FC1 = Line for Surface O{sub 2} + Well Head Gas + Reformer + PEMFC + Lead-Acid & Li-Ion Batteries; (3) FC2 = Stored O2 + Well Head Gas + Reformer + Fuel Cell + Lead-Acid & Li-Ion Batteries; (4) SV1 = Submersible Vehicle + Stored O{sub 2} + Fuel Cell + Lead-Acid & Li-Ion Batteries; (5) SV2 = Submersible Vehicle + Stored O{sub 2} + Engine or Turbine + Lead-Acid & Li-Ion Batteries; (6) SV3 = Submersible Vehicle + Charge at Docking Station + ZEBRA & Li-Ion Batteries; (7) PWR TEG = PWR + Thermoelectric Generator + Lead-Acid Battery; (8) WELL TEG = Thermoelectric Generator + Well Head Waste Heat + Lead-Acid Battery; (9) GRID = Ocean Floor Electrical Grid + Lead-Acid Battery; and (10) DOC = Deep Ocean Current + Lead-Acid Battery.

  20. A Hybrid Maximum Power Point Tracking Method for Automobile Exhaust Thermoelectric Generator

    Science.gov (United States)

    Quan, Rui; Zhou, Wei; Yang, Guangyou; Quan, Shuhai

    2017-05-01

    To make full use of the maximum output power of automobile exhaust thermoelectric generator (AETEG) based on Bi2Te3 thermoelectric modules (TEMs), taking into account the advantages and disadvantages of existing maximum power point tracking methods, and according to the output characteristics of TEMs, a hybrid maximum power point tracking method combining perturb and observe (P&O) algorithm, quadratic interpolation and constant voltage tracking method was put forward in this paper. Firstly, it searched the maximum power point with P&O algorithms and a quadratic interpolation method, then, it forced the AETEG to work at its maximum power point with constant voltage tracking. A synchronous buck converter and controller were implemented in the electric bus of the AETEG applied in a military sports utility vehicle, and the whole system was modeled and simulated with a MATLAB/Simulink environment. Simulation results demonstrate that the maximum output power of the AETEG based on the proposed hybrid method is increased by about 3.0% and 3.7% compared with that using only the P&O algorithm and the quadratic interpolation method, respectively. The shorter tracking time is only 1.4 s, which is reduced by half compared with that of the P&O algorithm and quadratic interpolation method, respectively. The experimental results demonstrate that the tracked maximum power is approximately equal to the real value using the proposed hybrid method,and it can preferentially deal with the voltage fluctuation of the AETEG with only P&O algorithm, and resolve the issue that its working point can barely be adjusted only with constant voltage tracking when the operation conditions change.

  1. A hybrid solar panel maximum power point search method that uses light and temperature sensors

    Science.gov (United States)

    Ostrowski, Mariusz

    2016-04-01

    Solar cells have low efficiency and non-linear characteristics. To increase the output power solar cells are connected in more complex structures. Solar panels consist of series of connected solar cells with a few bypass diodes, to avoid negative effects of partial shading conditions. Solar panels are connected to special device named the maximum power point tracker. This device adapt output power from solar panels to load requirements and have also build in a special algorithm to track the maximum power point of solar panels. Bypass diodes may cause appearance of local maxima on power-voltage curve when the panel surface is illuminated irregularly. In this case traditional maximum power point tracking algorithms can find only a local maximum power point. In this article the hybrid maximum power point search algorithm is presented. The main goal of the proposed method is a combination of two algorithms: a method that use temperature sensors to track maximum power point in partial shading conditions and a method that use illumination sensor to track maximum power point in equal illumination conditions. In comparison to another methods, the proposed algorithm uses correlation functions to determinate the relationship between values of illumination and temperature sensors and the corresponding values of current and voltage in maximum power point. In partial shading condition the algorithm calculates local maximum power points bases on the value of temperature and the correlation function and after that measures the value of power on each of calculated point choose those with have biggest value, and on its base run the perturb and observe search algorithm. In case of equal illumination algorithm calculate the maximum power point bases on the illumination value and the correlation function and on its base run the perturb and observe algorithm. In addition, the proposed method uses a special coefficient modification of correlation functions algorithm. This sub

  2. Rotating-Disk-Based Hybridized Electromagnetic-Triboelectric Nanogenerator for Sustainably Powering Wireless Traffic Volume Sensors.

    Science.gov (United States)

    Zhang, Binbin; Chen, Jun; Jin, Long; Deng, Weili; Zhang, Lei; Zhang, Haitao; Zhu, Minhao; Yang, Weiqing; Wang, Zhong Lin

    2016-06-28

    Wireless traffic volume detectors play a critical role for measuring the traffic-flow in a real-time for current Intelligent Traffic System. However, as a battery-operated electronic device, regularly replacing battery remains a great challenge, especially in the remote area and wide distribution. Here, we report a self-powered active wireless traffic volume sensor by using a rotating-disk-based hybridized nanogenerator of triboelectric nanogenerator and electromagnetic generator as the sustainable power source. Operated at a rotating rate of 1000 rpm, the device delivered an output power of 17.5 mW, corresponding to a volume power density of 55.7 W/m(3) (Pd = P/V, see Supporting Information for detailed calculation) at a loading resistance of 700 Ω. The hybridized nanogenerator was demonstrated to effectively harvest energy from wind generated by a moving vehicle through the tunnel. And the delivered power is capable of triggering a counter via a wireless transmitter for real-time monitoring the traffic volume in the tunnel. This study further expands the applications of triboelectric nanogenerators for high-performance ambient mechanical energy harvesting and as sustainable power sources for driving wireless traffic volume sensors.

  3. Power Management Optimization of an Experimental Fuel Cell/Battery/Supercapacitor Hybrid System

    Directory of Open Access Journals (Sweden)

    Farouk Odeim

    2015-06-01

    Full Text Available In this paper, an experimental fuel cell/battery/supercapacitor hybrid system is investigated in terms of modeling and power management design and optimization. The power management strategy is designed based on the role that should be played by each component of the hybrid power source. The supercapacitor is responsible for the peak power demands. The battery assists the supercapacitor in fulfilling the transient power demand by controlling its state-of-energy, whereas the fuel cell system, with its slow dynamics, controls the state-of-charge of the battery. The parameters of the power management strategy are optimized by a genetic algorithm and Pareto front analysis in a framework of multi-objective optimization, taking into account the hydrogen consumption, the battery loading and the acceleration performance. The optimization results are validated on a test bench composed of a fuel cell system (1.2 kW, 26 V, lithium polymer battery (30 Ah, 37 V, and a supercapacitor (167 F, 48 V.

  4. Wind-hydrogen-biomass. The hybrid power plant of ENERTRAG AG

    Energy Technology Data Exchange (ETDEWEB)

    Miege, Andreas; Luschtinetz, T. [Fachhochschule Stralsund (Germany); Wenske, M.; Gamallo, F. [ENERTRAG AG (Germany)

    2010-07-01

    The ENERTRAG Hybrid Power Plant is designed around the following components: three wind turbines of 2 MW each, an electrolyser of 500 kW, a hydrogen storage system, and two CHP units of 350 kW each, able to run with variable mixtures of biogas and hydrogen. The use of the electrolyser - acting as a deferrable load, and running under variable power - and the possibility of reconverting the hydrogen again into electricity will allow a feeding-in of the produced electricity to the grid, free of any of the changing characteristics of the wind power. Besides of that renewable electricity, the Hybrid Power Plant will also be able of delivering hydrogen as a clean fuel for the transport sector, as well as oxygen and heat. The project will show that renewable energy sources, like wind and solar, will be able, in the future, of producing back-up power without any support of fossile sources; and also of feeding electricity to the grid as a part of the base-load demand. As a first step towards this direction, the project has the goal of assuring that the energy production of the three wind turbines will be in accordance to the 24-h-forecasted wind power values. (orig.)

  5. Energy Management and Control of Electric Vehicles, Using Hybrid Power Source in Regenerative Braking Operation

    Directory of Open Access Journals (Sweden)

    Bo Long

    2014-07-01

    Full Text Available Today’s battery powered electric vehicles still face many issues: (1 Ways of improving the regenerative braking energy; (2 how to maximally extend the driving-range of electric vehicles (EVs and prolong the service life of batteries; (3 how to satisfy the energy requirements of the EVs both in steady and dynamic state. The electrochemical double-layer capacitors, also called ultra-capacitors (UCs, have the merits of high energy density and instantaneous power output capability, and are usually combined with power battery packs to form a hybrid power supply system (HPSS. The power circuit topology of the HPSS has been illustrated in this paper. In the proposed HPSS, all the UCs are in series, which may cause an imbalanced voltage distribution of each unit, moreover, the energy allocation between the batteries and UCs should also be considered. An energy-management scheme to solve this problem has been presented. Moreover, due to the parameter variations caused by temperature changes and produced errors, the modelling procedure of the HPSS becomes very difficult, so an H∞ current controller is presented. The proposed hybrid power source circuit is implemented on a laboratory hardware setup using a digital signal processor (DSP. Simulation and experimental results have been put forward to demonstrate the feasibility and validity of the approach.

  6. Direct switching control of DC-DC power electronic converters using hybrid system theory

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, J.; Lin, F. [Wayne State Univ., Detroit, MI (United States). Dept. of Electrical and Computer Engineering; Wang, C. [Wayne State Univ., Detroit, MI (United States). Dept. of Electrical and Computer Engineering; Wayne State Univ., Detroit, MI (United States). Div. of Engineering Technology

    2010-07-01

    A direct switching control (DSC) scheme for power electronics converters was described. The system was designed for use in both traditional and renewable energy applications as well as in electric drive vehicles. The proposed control scheme was based on a detailed hybrid system converter model that used model predictive control (MPC), piecewise affine (PWA) approximations and constrained optimal control methods. A DC-DC converter was modelled as a hybrid machine. Switching among different modes of the DC-DC converter were modelled as discrete events controlled by the hybrid controller. The modelling scheme was applied to a Buck converter. The DSC was used to control the switch of the power converter based on a hybrid machine model. Results of the study showed that the method can be used to regulate output voltage and inductor currents. The method also provides fast transient responses and effectively regulates both currents and voltage. The controller can be used to provide immediate responses to dynamic disturbances and output voltage fluctuations. 23 refs., 7 figs.

  7. Development of integrated fuel cell hybrid power source for electric forklift

    Science.gov (United States)

    Keränen, T. M.; Karimäki, H.; Viitakangas, J.; Vallet, J.; Ihonen, J.; Hyötylä, P.; Uusalo, H.; Tingelöf, T.

    A hybrid drivetrain comprising a 16 kW polymer electrolyte membrane fuel cell system, ultracapacitor modules and a lead-acid battery was constructed and experimentally tested in a real counterweight forklift application. A scaled-down version of the hybrid system was assembled and tested in a controlled laboratory environment using a controllable resistive load. The control loops were operating in an in-house developed embedded system. The software is designed for building generic control applications, and the source code has been released as open source and made available on the internet. The hybrid drivetrain supplied the required 50 kW peak power in a typical forklift work cycle consisting of both loaded and unloaded driving, and lifting of a 2.4 tonne load. Load variations seen by the fuel cell were a fraction of the total current drawn by the forklift, with the average fuel cell power being 55% of nominal rating. A simple fuel cell hybrid model was also developed to further study the effects of energy storage dimensioning. Simulation results indicate that while a battery alone significantly reduces the load variations of the fuel cell, an ultracapacitor reduces them even further. Furthermore, a relatively small ultracapacitor is enough to achieve most of the potential benefit.

  8. Stand-alone hybrid wind-photovoltaic power generation systems optimal sizing

    Science.gov (United States)

    Crǎciunescu, Aurelian; Popescu, Claudia; Popescu, Mihai; Florea, Leonard Marin

    2013-10-01

    Wind and photovoltaic energy resources have attracted energy sectors to generate power on a large scale. A drawback, common to these options, is their unpredictable nature and dependence on day time and meteorological conditions. Fortunately, the problems caused by the variable nature of these resources can be partially overcome by integrating the two resources in proper combination, using the strengths of one source to overcome the weakness of the other. The hybrid systems that combine wind and solar generating units with battery backup can attenuate their individual fluctuations and can match with the power requirements of the beneficiaries. In order to efficiently and economically utilize the hybrid energy system, one optimum match design sizing method is necessary. In this way, literature offers a variety of methods for multi-objective optimal designing of hybrid wind/photovoltaic (WG/PV) generating systems, one of the last being genetic algorithms (GA) and particle swarm optimization (PSO). In this paper, mathematical models of hybrid WG/PV components and a short description of the last proposed multi-objective optimization algorithms are given.

  9. Technico-economic assessment of hybrid diesel-photovoltaic power plant in the south of Algeria

    Science.gov (United States)

    Kadri, A. Y.; Hamidat, A.

    2016-07-01

    In Algeria, Electrical energy demand has knew a significant growth in recent years. The important increase in demand is due to the development of industrial and commercial sectors, and the comfort of residents customers by using multiple equipment of household such as the TV, ventilator, especially air-conditioners in the south of Algeria. To address the problem of imbalance between supply and demand, it is compulsory to add other units of productions of electricity. These units can be use conventional sources or renewable energy sources. This study focuses on the feasibility of hybridizing diesel power plants supplying the isolated villages in southern Algeria by the introduction of PV systems. The town of Djanet was taken as a case study. The comparison between the different technical and economic parameters allows determining the contribution of the hybridization of conventional resources of production. However, the cost-effectiveness based on the net present cost (NPC) is estimated at 176, 054.208 for the hybrid system and 194, 965.280 for all Diesel system. In terms of the cost per kWh produced by the two systems, the kWh produced by the hybrid system is less expensive than the kWh produced by any conventional diesel system is 0.551 / kWh against 0.610 / kWh. The results also show that the hybrid system provides coverage of the expected load in the future.

  10. Robust design and optimization for autonomous PV-wind hybrid power systems

    Institute of Scientific and Technical Information of China (English)

    Jun-hai SHI; Zhi-dan ZHONG; Xin-jian ZHU; Guang-yi CAO

    2008-01-01

    This study presents a robust design method for autonomous photovoltaic (PV)-wind hybrid power systems to obtain an optimum system configuration insensitive to design variable variations. This issue has been formulated as a constraint multi-objective optimization problem, which is solved by a multi-objective genetic algorithm, NSGA-Ⅱ. Monte Carlo Simulation (MCS) method, combined with Latin Hypercube Sampling (LHS), is applied to evaluate the stochastic system performance. The potential of the proposed method has been demonstrated by a conceptual system design. A comparative study between the proposed robust method and the deterministic method presented in literature has been conducted. The results indicate that the proposed method can find a large mount of Pareto optimal system configurations with better compromising performance than the deterministic method. The trade-off information may be derived by a systematical comparison of these configurations. The proposed robust design method should be useful for hybrid power systems that require both optimality and robustness.

  11. Utilizing wind and solar energy as power sources for a hybrid building ventilation device

    Energy Technology Data Exchange (ETDEWEB)

    Shun, Simon; Ahmed, Noor A. [School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney (Australia)

    2008-06-15

    Wind and solar energy are currently used to power many building ventilation devices. Such devices rely exclusively on either solar or wind energy, which limits their usefulness. A low-cost hybrid ventilation device that utilizes both wind and solar energy as power sources was designed to overcome some of the shortcomings of these devices. Wind tunnel testing conducted at the aerodynamics laboratory of the University of New South Wales revealed that the hybrid device had improved operational and performance benefits compared with conventional commercial roof top ventilators, particularly at zero to low wind speeds. This represents a significant step forward and will have an immediate impact in promoting the use of clean energy for the purposes of building ventilation. (author)

  12. Design and Comparison of Power Systems for a Fuel Cell Hybrid Electric Vehicle

    DEFF Research Database (Denmark)

    Schaltz, Erik; Rasmussen, Peter Omand

    2008-01-01

    In a fuel cell hybrid electric vehicle (FCHEV) the fuel cell stack is assisted by one or more energy storage devices. Thereby the system cost, mass, and volume can be decreased, and a significant better performance can be obtained. Two often used energy storage devices are the battery...... and ultracapacitor. In this paper a design method to design the power system of a FCHEV is presented. 10 cases of combining the fuel stack with either the battery, ultracapacitor, or both are investigated. The system volume, mass, efficiency, and battery lifetime are also compared. It is concluded that when...... ultracapacitors are the only energy storage device the system becomes too big and heavy. A fuel cell/battery/ultracapacitor hybrid provides the longest life time of the batteries. If the fuel cell stack power is too small, the system will be big, heavy, and have a poor efficiency....

  13. Very long pulse high-RF power test of a lower hybrid frequency antenna module

    Energy Technology Data Exchange (ETDEWEB)

    Goniche, M.; Brossaud, J.; Barral, C.; Berger-By, G.; Bibet, Ph.; Poli, S.; Rey, G.; Tonon, G. [Association Euratom-CEA, Centre d`Etudes Nucleaires de Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee; Seki, M.; Obara, K. [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment] [and others

    1994-03-01

    Outgassing, induced by very long RF waves injection at high power density was studied in a module, able to be used for a lower hybrid frequency antenna. Good RF properties of the module are reported, however, resonance phenomena with strong absorption of RF power (15%) was observed at high temperature (T>400 deg C). A large outgassing data base is provided by the 75 shots cumulating 27 hours of RF injection. The comparison with previous experiments (Tore Supra and TdV prototype modules) confirm the effect of baking and results are consistent. Outgassing increases exponentially with -1/T, and a desorption model with an activation energy Ed {approx} 0.35 eV fits the data up to 400 deg C. In order to design vacuum pumping system for large lower hybrid frequency antenna, outgassing rates are given for different working temperatures. (author). 11 refs., 55 figs.

  14. A Hybrid Estimator for Active/Reactive Power Control of Single-Phase Distributed Generation Systems with Energy Storage

    DEFF Research Database (Denmark)

    Pahlevani, Majid; Eren, Suzan; Guerrero, Josep M.;

    2016-01-01

    This paper presents a new active/reactive power closed-loop control system for a hybrid renewable energy generation system used for single-phase residential/commercial applications. The proposed active/reactive control method includes a hybrid estimator, which is able to quickly and accurately...... estimate the active/reactive power values. The proposed control system enables the hybrid renewable energy generation system to be able to perform real-time grid interconnection services such as active voltage regulation, active power control, and fault ride-through.Simulation and experimental results...... demonstrate the superior performance of the proposed closed-loop control system....

  15. Power quality control of an autonomous wind-diesel power system based on hybrid intelligent controller.

    Science.gov (United States)

    Ko, Hee-Sang; Lee, Kwang Y; Kang, Min-Jae; Kim, Ho-Chan

    2008-12-01

    Wind power generation is gaining popularity as the power industry in the world is moving toward more liberalized trade of energy along with public concerns of more environmentally friendly mode of electricity generation. The weakness of wind power generation is its dependence on nature-the power output varies in quite a wide range due to the change of wind speed, which is difficult to model and predict. The excess fluctuation of power output and voltages can influence negatively the quality of electricity in the distribution system connected to the wind power generation plant. In this paper, the authors propose an intelligent adaptive system to control the output of a wind power generation plant to maintain the quality of electricity in the distribution system. The target wind generator is a cost-effective induction generator, while the plant is equipped with a small capacity energy storage based on conventional batteries, heater load for co-generation and braking, and a voltage smoothing device such as a static Var compensator (SVC). Fuzzy logic controller provides a flexible controller covering a wide range of energy/voltage compensation. A neural network inverse model is designed to provide compensating control amount for a system. The system can be optimized to cope with the fluctuating market-based electricity price conditions to lower the cost of electricity consumption or to maximize the power sales opportunities from the wind generation plant.

  16. Hybrid power train for light commercial vehicles; Hybridantriebsstrang fuer leichte Nutzfahrzeuge

    Energy Technology Data Exchange (ETDEWEB)

    Somschor, B.; Buchhold, O. (ZF Friedrichshafen AG, Friedrichshafen)

    2007-07-01

    Light commercial vehicles are a rapidly growing vehicle segment. These vehicles are used for several purposes e.g. supply of different goods, construction areas, special applications. A high number of vehicles are used in cities or in urban arena with a high density of traffic and typical environmental polluting. In the meantime legislation in several industrialized countries around the world have the target to protect environment, e.g., Euro 4 or 5 regulations or Japan 10. In parallel the automotive industries (ACEA) in Europe has given a self obligation to reduce the CO{sub 2} emission until 2008 to a value of 140 g/km. A lot of activities are started by automotive industry and there suppliers in the past to meet these requirements. Beside already well known development activities like weight optimisation, lower driving and air resistance or improved diesel engine the hybrid power train, a combination of electric motor generator and combustion engine seems to be in the future an imported solution to meet these requirements in the future. Several possibilities to realize a hybrid power train for these applications is shown including the possibilities ZF have to show a hybrid power train for these types of applications. Advantages and disadvantages of the several possibilities are discussed from different point of view. The needed basic functions of a hybrid power train are discussed and system is recommended to use for these types of applications. A simulation model is shown and described including the realisation and results for different driving cycles. The influence on fuel consumption and emissions divided by functions are shown. A solution optimised for light commercial application is shown. Further more first results based on practical experiences are described. (orig.)

  17. Recent Work in Hybrid Radiation Transport Methods with Applications to Commercial Nuclear Power

    Energy Technology Data Exchange (ETDEWEB)

    Kulesza, Joel A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-03-20

    This talk will begin with an overview of hybrid radiation transport methods followed by a discussion of the author’s work to advance current capabilities. The talk will then describe applications for these methods in commercial nuclear power reactor analyses and techniques for experimental validation. When discussing these analytical and experimental activities, the importance of technical standards such as those created and maintained by ASTM International will be demonstrated.

  18. Two-loop controller for maximizing performance of a grid-connected photovoltaic - fuel cell hybrid power plant

    Science.gov (United States)

    Ro, Kyoungsoo

    The study started with the requirement that a photovoltaic (PV) power source should be integrated with other supplementary power sources whether it operates in a stand-alone or grid-connected mode. First, fuel cells for a backup of varying PV power were compared in detail with batteries and were found to have more operational benefits. Next, maximizing performance of a grid-connected PV-fuel cell hybrid system by use of a two-loop controller was discussed. One loop is a neural network controller for maximum power point tracking, which extracts maximum available solar power from PV arrays under varying conditions of insolation, temperature, and system load. A real/reactive power controller (RRPC) is the other loop. The RRPC meets the system's requirement for real and reactive powers by controlling incoming fuel to fuel cell stacks as well as switching control signals to a power conditioning subsystem. The RRPC is able to achieve more versatile control of real/reactive powers than the conventional power sources since the hybrid power plant does not contain any rotating mass. Results of time-domain simulations prove not only effectiveness of the proposed computer models of the two-loop controller, but also their applicability for use in transient stability analysis of the hybrid power plant. Finally, environmental evaluation of the proposed hybrid plant was made in terms of plant's land requirement and lifetime COsb2 emissions, and then compared with that of the conventional fossil-fuel power generating forms.

  19. Compact and Wideband Parallel-Strip 180° Hybrid Coupler with Arbitrary Power Division Ratios

    Directory of Open Access Journals (Sweden)

    Leung Chiu

    2013-01-01

    Full Text Available This paper presents a class of wideband 180° hybrid (rat race couplers implemented by parallel-strip line. By replacing the 270° arm of a conventional 180° hybrid coupler by a 90° arm with phase inverter, the bandwidth of the coupler is greatly enhanced and the total circuit size is reduced by almost half. Simple design formulas relating the characteristic impedance of the arms and power division ration are derived. To demonstrate the concept, four couplers with different power division ratios of 1, 2, 4, and 8 were designed, fabricated, and tested. S-parameters of the coupler are simulated and measured with good agreement. All working prototypes operate more than 112% impedance bandwidth with more than 25 dB port-to-port isolation and less than 5° absolute phase imbalance. The proposed 180° hybrid couplers can be employed as a wideband in-phase/differential power divider/combiner, which are essential for many RF and microwave subsystem designs.

  20. An immune-tabu hybrid algorithm for thermal unit commitment of electric power systems

    Institute of Scientific and Technical Information of China (English)

    Wei LI; Hao-yu PENG; Wei-hang ZHU; De-ren SHENG; Jian-hong CHEN

    2009-01-01

    This paper presents a new method based on an immune-tabu hybrid algorithm to solve the thermal unit commitment (TUC) problem in power plant optimization. The mathematical model of the TUC problem is established by analyzing the generating units in modern power plants. A novel immune-tabu hybrid algorithm is proposed to solve this complex problem. In the algorithm, the objective function of the TUC problem is considered as an antigen and the solutions are considered as antibodies,which are determined by the affinity computation. The code length of an antibody is shortened by encoding the continuous operating time, and the optimum searching speed is improved. Each feasible individual in the immune algorithm (IA) is used as the initial solution of the tabu search (TS) algorithm after certain generations of IA iteration. As examples, the proposed method has been applied to several thermal unit systems for a period of 24 h. The computation results demonstrate the good global optimum searching performance of the proposed immune-tabu hybrid algorithm. The presented algorithm can also be used to solve other optimization problems in fields such as the chemical industry and the power industry.

  1. A Hybrid Islanding Detection Technique Using Average Rate of Voltage Change and Real Power Shift

    DEFF Research Database (Denmark)

    Mahat, Pukar; Chen, Zhe; Bak-Jensen, Birgitte

    2009-01-01

    technique is proposed to solve this problem. An average rate of voltage change (passive technique) has been used to initiate a real power shift (active technique), which changes the eal power of distributed generation (DG), when the passive technique cannot have a clear discrimination between islanding......The mainly used islanding detection techniques may be classified as active and passive techniques. Passive techniques don't perturb the system but they have larger nondetection znes, whereas active techniques have smaller nondetection zones but they perturb the system. In this paper, a new hybrid...

  2. Digital Control of a power conditioner for fuel cell/super-capacitor hybrid system

    DEFF Research Database (Denmark)

    Caballero, Juan C Trujillo; Gomis-Bellmunt, Oriol; Montesinos-Miracle, Daniel

    2014-01-01

    This article proposes a digital control scheme to operate a proton exchange membrane fuel cell module of 1.2 kW and a super-capacitor through a DC/DC hybrid converter. A fuel cell has been proposed as a primary source of energy, and a super-capacitor has been proposed as an auxiliary source...... of energy. Experimental validation of the system implemented in the laboratory is provided. Several tests have been performed to verify that the system achieves excellent output voltage (V0) regulation and super-capacitor voltage (V SC) control under disturbances from fuel cell power (PFC) and output power...

  3. Digital Control of a power conditioner for fuel cell/super-capacitor hybrid system

    DEFF Research Database (Denmark)

    Caballero, Juan C Trujillo; Gomis-Bellmunt, Oriol; Montesinos-Miracle, Daniel;

    2014-01-01

    This article proposes a digital control scheme to operate a proton exchange membrane fuel cell module of 1.2 kW and a super-capacitor through a DC/DC hybrid converter. A fuel cell has been proposed as a primary source of energy, and a super-capacitor has been proposed as an auxiliary source...... of energy. Experimental validation of the system implemented in the laboratory is provided. Several tests have been performed to verify that the system achieves excellent output voltage (V0) regulation and super-capacitor voltage (V SC) control under disturbances from fuel cell power (PFC) and output power...

  4. Hybrid Active Filter with Variable Conductance for Harmonic Resonance Suppression in Industrial Power Systems

    DEFF Research Database (Denmark)

    Lee, Tzung-Lin; Wang, Yen-Ching; Li, Jian-Cheng

    2015-01-01

    -tuned passive filter and an active filter in series connection, both dc voltage and kVA rating of the active filter are dramatically decreased compared with the pure shunt active filter. In real application, this feature is very attractive since the active power filter with fully power electronics is very...... expensive. A reasonable trade-off between filtering performances and cost is to use the hybrid active filter. Design consideration are presented and experimental results are provided to validate effectiveness of the proposed method. Furthermore, this paper discusses filtering performances on line impedance...

  5. Single-Phase Hybrid Switched Reluctance Motor for Low-Power Low-Cost Applications

    DEFF Research Database (Denmark)

    Lu, Kaiyuan; Rasmussen, Peter Omand; Jakobsen, Uffe

    2011-01-01

    This paper presents a new single-phase, Hybrid Switched Reluctance (HSR) motor for low-cost, low-power, pump or fan drive systems. Its single-phase configuration allows use of a simple converter to reduce the system cost. Cheap ferrite magnets are used and arranged in a special flux concentration...... manner to increase effectively the torque density and efficiency of this machine. The efficiency of this machine is comparable to the efficiency of a traditional permanent magnet machine in the similar power range. The cogging torque, due to the existence of the permanent magnetic field, is beneficially...

  6. A Low Power VITERBI Decoder Design With Minimum Transition Hybrid Register Exchange Processing For Wireless Applications

    Directory of Open Access Journals (Sweden)

    S. L. Haridas

    2010-12-01

    Full Text Available This work proposes the low power implementation of Viterbi Decoder. Majority of viterbi decoder designs in the past use simple Register Exchange or Traceback method to achieve very high speed and low power decoding respectively, but it suffers from both complex routing and high switching activity.Here simplification is made in survivor memory unit by storing only m-1 bits to identify previous state in the survivor path, and by assigning m-1 registers to decision vectors. This approach eliminates unnecessary shift operations. Also for storing the decoded data only half memory is required than register exchange method. In this paper Hybrid approach that combines both Traceback and Register Exchange schemes has been applied to the viterbi decoder design. By using distance properties of encoder we further modified to minimum transition hybrid register exchange method. It leads to lower dynamic power consumption because of lower switching activity. Dynamic power estimation obtained through gate level simulation indicates that the proposed design reduces the power dissipation of a conventional viterbi decoder design by 30%.

  7. A Low Power VITERBI Decoder Design With Minimum Transition Hybrid Register Exchange Processing For Wireless Applications

    Directory of Open Access Journals (Sweden)

    S. L. Haridas

    2010-12-01

    Full Text Available This work proposes the low power implementation of Viterbi Decoder. Majority of viterbi decoder designs in the past use simple Register Exchange or Trace back method to achieve very high speed and low power decoding respectively, but it suffers from both complex routing and high switching activity.Here simplification is made in survivor memory unit by storing only m-1 bits to identify previous state in the survivor path, and by assigning m-1 registers to decision vectors. This approach eliminates unnecessary shift operations. Also for storing the decoded data only half memory is required than register exchange method. In this paper Hybrid approach that combines both Trace back and Register Exchange schemes has been applied to the viterbi decoder design. By using distance properties of encoder we further modified to minimum transition hybrid register exchange method. It leads to lower dynamic power consumption because of lower switching activity. Dynamic power estimation obtained through gate level simulation indicates that the proposed design reduces the power dissipation of a conventional viterbi decoder design by 30%.

  8. DESIGN OF HYBRID POWER GENERATION CYCLES EMPLOYING AMMONIA-WATER-CARBON DIOXIDE MIXTURES

    Energy Technology Data Exchange (ETDEWEB)

    Ashish Gupta

    2002-06-01

    A power cycle generates electricity from the heat of combustion of fossil fuels. Its efficiency is governed by the cycle configuration, the operating parameters, and the working fluid. Typical. designs use pure water as the fluid. in the last two decades, hybrid cycles based on ammonia-water, and carbon-dioxide mixtures as the working fluid have been proposed. These cycles may improve the power generation efficiency of Rankine cycles by 15%. Improved efficiency is important for two reasons: it lowers the cost of electricity being produced, and by reducing the consumption of fossil fuels per unit power, it reduces the generation of environmental pollutants. The goal of this project is to develop a computational optimization-based method for the design and analysis of hybrid bottoming power cycles to minimize the usage of fossil fuels. The development of this methodology has been achieved by formulating this task as that of selecting the least cost power cycle design from all possible configurations. They employ a detailed thermodynamic property prediction package they have developed under a DOE-FETC grant to model working fluid mixtures. Preliminary results from this work suggest that a pure NH{sub 3} cycle outperforms steam or the expensive Kalina cycle.

  9. Power Management Strategy of Hybrid Electric Vehicles Based on Quadratic Performance Index

    Directory of Open Access Journals (Sweden)

    Chaoying Xia

    2015-11-01

    Full Text Available An energy management strategy (EMS considering both optimality and real-time performance has become a challenge for the development of hybrid electric vehicles (HEVs in recent years. Previous EMSes based on the optimal control theory minimize the fuel consumption, but cannot be directly implemented in real-time because of the requirement for a prior knowledge of the entire driving cycle. This paper presents an innovative design concept and method to obtain a power management strategy for HEVs, which is independent of future driving conditions. A quadratic performance index is designed to ensure the vehicle drivability, maintain the battery energy sustainability and average and smooth the engine power and motor power to indirectly reduce fuel consumption. To further improve the fuel economy, two rules are adopted to avoid the inefficient engine operation by switching control modes between the electric and hybrid modes according to the required driving power. The derived power of the engine and motor are related to current vehicle velocity and battery residual energy, as well as their desired values. The simulation results over different driving cycles in Advanced Vehicle Simulator (ADVISOR show that the proposed strategy can significantly improve the fuel economy, which is very close to the optimal strategy based on Pontryagin’s minimum principle.

  10. PEMFC Optimization Strategy with Auxiliary Power Source in Fuel Cell Hybrid Vehicle

    Directory of Open Access Journals (Sweden)

    Tinton Dwi Atmaja

    2012-02-01

    Full Text Available Page HeaderOpen Journal SystemsJournal HelpUser You are logged in as...aulia My Journals My Profile Log Out Log Out as UserNotifications View (27 new ManageJournal Content SearchBrowse By Issue By Author By Title Other JournalsFont SizeMake font size smaller Make font size default Make font size largerInformation For Readers For Authors For LibrariansKeywords CBPNN Displacement FLC LQG/LTR Mixed PMA Ventilation bottom shear stress direct multiple shooting effective fuzzy logic geoelectrical method hourly irregular wave missile trajectory panoramic image predator-prey systems seawater intrusion segmentation structure development pattern terminal bunt manoeuvre Home About User Home Search Current Archives ##Editorial Board##Home > Vol 23, No 1 (2012 > AtmajaPEMFC Optimization Strategy with Auxiliary Power Source in Fuel Cell Hybrid VehicleTinton Dwi Atmaja, Amin AminAbstractone of the present-day implementation of fuel cell is acting as main power source in Fuel Cell Hybrid Vehicle (FCHV. This paper proposes some strategies to optimize the performance of Polymer Electrolyte Membrane Fuel Cell (PEMFC implanted with auxiliary power source to construct a proper FCHV hybridization. The strategies consist of the most updated optimization method determined from three point of view i.e. Energy Storage System (ESS, hybridization topology and control system analysis. The goal of these strategies is to achieve an optimum hybridization with long lifetime, low cost, high efficiency, and hydrogen consumption rate improvement. The energy storage system strategy considers battery, supercapacitor, and high-speed flywheel as the most promising alternative auxiliary power source. The hybridization topology strategy analyzes the using of multiple storage devices injected with electronic components to bear a higher fuel economy and cost saving. The control system strategy employs nonlinear control system to optimize the ripple factor of the voltage and the current

  11. Hybrid solution for the laminar flow of power-law fluids inside rectangular ducts

    Science.gov (United States)

    Lima, J. A.; Pereira, L. M.; Macêdo, E. N.; Chaves, C. L.; Quaresma, J. N. N.

    The so-called generalized integral transform technique (GITT) is employed in the hybrid numerical-analytical solution of two-dimensional fully-developed laminar flow of non-Newtonian power-law fluids inside rectangular ducts. The characteristic of the automatic and straightforward global error control procedure inherent to this approach, permits the determination of fully converged benchmark results to assess the performance of purely numerical techniques. Therefore, numerical results for the product Fanning friction factor-generalized Reynolds number are computed for different values of power-law index and aspect ratio, which are compared with previously reported results in the literature, providing critical comparisons among them as well as illustrating the powerfulness of the integral transform approach. The resulting velocity profiles computed by using this methodology are also compared with those calculated by approximated methods for power-law fluids, within the range of governing parameters studied.

  12. Power electronics and electric machinery challenges and opportunities in electric and hybrid vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Adams, D.J.; Hsu, J.S.; Young, R.W. [Oak Ridge National Lab., TN (United States); Peng, F.Z. [Univ. of Tennessee, Knoxville, TN (United States)

    1997-06-01

    The development of power electronics and electric machinery presents significant challenges to the advancement of electric and hybrid vehicles. Electronic components and systems development for vehicle applications have progressed from the replacement of mechanical systems to the availability of features that can only be realized through interacting electronic controls and devices. Near-term applications of power electronics in vehicles will enable integrated powertrain controls, integrated chassis system controls, and navigation and communications systems. Future applications of optimized electric machinery will enable highly efficient and lightweight systems. This paper will explore the areas where research and development is required to ensure the continued development of power electronics and electric machines to meet the rigorous demands of automotive applications. Additionally, recent advances in automotive related power electronics and electric machinery at Oak Ridge National Laboratory will be explained. 3 refs., 5 figs.

  13. Overview of Power Generation Sector of Bangladesh and Proposed Grid Connected Hybrid Renewable Energy System

    Directory of Open Access Journals (Sweden)

    Md. Raju Ahmed

    2014-11-01

    Full Text Available Electricity is the most usable form of energy, and one of the most crucial strategic issues for the sustainable development of a country. The projection of demand of electricity is an integral part of the planning process. Severe power crisis compelled the government to enter into contractual agreements for high-cost temporary solution such as rental power and small IPPS, on an emergency basis, most of these are diesel or liquid-fuel based. Load shading is an acute problem for the country. The country is confronting a simultaneous shortage of electricity. However, the country has substantial amount of renewable energy resources. The overview of power generation section of Bangladesh is presented; the potentiality of renewable energy sources in Bangladesh is discussed. Finally, a grid connected hybrid renewable energy system is proposed to overcome the problem of power crisis using sustainable clean energy at rural area.

  14. Design of Solar/Electric Powered Hybrid Vehicle (SEPHV) System with Charge Pattern Optimization for Energy Cost

    OpenAIRE

    T Balamurugan; Dr.S.Manoharan

    2014-01-01

    This paper proposes a Solar Electric Powered Hybrid Vehicle (SEPHV) system which solves the major problems of fuel and pollution. An electric vehicle usually uses a battery which has been charged by external electrical power supply. All recent electric vehicles present a drive on AC power supplied motor. An inverter set is required to be connected with the battery through which AC power is converted to DC power. During this conversion many losses take place and also the maintenance cost of th...

  15. Performance Analysis of a MCFC/MGT Hybrid Power System Bi-Fueled by City Gas and Biogas

    Directory of Open Access Journals (Sweden)

    Hongyu Huang

    2015-06-01

    Full Text Available This study evaluates the performance of a molten carbonate fuel cell and micro gas turbine (MCFC/MGT hybrid power system bi-fueled by city gas and biogas. The performance of the MCFC/MGT hybrid power system and MFCF/MGT hybrid power system response have been investigated experimentally and numerically. Results show that the MCFC, steam reformer, and catalytic combustor models are in agreement with the experimental results of the system fueled by city gas only and the system bi-fueled by city gas and biogas. The MFCF/MGT hybrid power system can have manifest operation with the addition of biogas at a flow rate of up to 150.0 Nm3·h−1, which is about 50% of the overall input heat value. In addition, the MCFC and MGT outputs decrease with the increase in the flow rate of added biogas, with an overall power generation efficiency ranging from 39.0% to 42.0%. Furthermore, the MCFC/MGT hybrid power system can be operated stably both at low amplitude with slow current change and large amplitude with rapid power conditions. Finally, the MCFC/MGT hybrid system bi-fueled by city gas and biogas may be applicable to the energy supply of the micro–grid network.

  16. Dynamic Modelling of a Wind/Fuel-Cell/Ultra-Capacitor-Based Hybrid Power Generation System

    Directory of Open Access Journals (Sweden)

    J. Vanishree

    2014-01-01

    Full Text Available Recent research and development of alternative energy sources have shown excellent potential as a form of contribution to conventional power generation systems. In order to meet sustained load demands during varying natural conditions, different energy sources and converters need to be integrated with each other for extended usage of alternative energy. The paper focuses on the combination of wind, Fuel Cell (FC and Ultra-Capacitor (UC systems for sustained power generation. As the wind turbine output power varies with the wind speed: an FC system with a UC bank can be integrated with the wind turbine to ensure that the system performs under all conditions. A dynamic model, design and simulation of a wind/FC/UC hybrid power generation system with power flow controllers is proposed. In the proposed system, when the wind speed is sufficient, the wind turbine can meet the load demand. If the available power from the wind turbine cannot satisfy the load demand, the FC system can meet the excess power demand, while the UC can meet the load demand above the maximum power available from the FC system for short durations. Furthermore, this system can tolerate the rapid changes in wind speed and suppress the effects of these fluctuations on the equipment side voltage in a novel topology.

  17. Strategy Design of Hybrid Energy Storage System for Smoothing Wind Power Fluctuations

    Directory of Open Access Journals (Sweden)

    Jingyu Liu

    2016-11-01

    Full Text Available With the increasing contribution of wind power plants, the reliability and security of modern power systems have become a huge challenge due to the uncertainty and intermittency of wind energy sources. In this paper, a hybrid energy storage system (HESS consisting of battery and supercapacitor is built to smooth the power fluctuations of wind power. A power allocation strategy is proposed to give full play to the respective advantages of the two energy storage components. In the proposed strategy, the low-frequency and high-frequency components of wind power fluctuations are absorbed by battery groups and supercapacitor groups, respectively. By inhibiting the low-frequency components of supercapacitor current, the times of charging-discharging of battery groups can be significantly reduced. A DC/AC converter is applied to achieve the power exchange between the HESS and the grid. Adjustment rules for regulating state-of-charge (SOC of energy storage elements are designed to avoid overcharge and deep discharge considering the safety and the high efficiency of the energy storage elements. Experimental results on the test platform verify the effectiveness of the proposed power allocation strategy in DC/AC converter and battery SOC adjustment rules for regulating SOC levels.

  18. Feedback control of the lower hybrid power deposition profile on Tore Supra

    Science.gov (United States)

    Barana, O.; Mazon, D.; Laborde, L.; Turco, F.

    2007-07-01

    The Tore Supra facility is well suited to study ITER relevant topics such as the real-time control of plasma current and the sustaining of steady-state discharges. This work describes a tool that was recently developed and implemented on Tore Supra to control in real time, by means of the direct knowledge of the suprathermal electron local emission profile, the width of the lower hybrid power deposition profile. This quantity can be considered to some extent equivalent to the width of the plasma current density profile in case of fully non-inductive discharges. This system takes advantage of an accurate hard x-ray diagnostics, of an efficient lower hybrid additional heating and of a reliable real-time communication network. The successful experiments carried out to test the system employed, as actuators, the parallel refractive index n// and the total power PLH. The control of the suprathermal electron local emission profile through n// was also integrated with the feedback control of the total plasma current IP with PLH and of the loop voltage Vloop with the central solenoid flux. These results demonstrate that the system is robust, reliable and able to counterbalance destabilizing events. This tool can be effectively used in the future in fully non-inductive discharges to improve the MHD stability and to maintain internal transport barriers or lower hybrid enhanced performance modes. The real-time control of the lower hybrid power deposition profile could also be used in conjunction with the electron-cyclotron radiofrequency heating for synergy studies.

  19. Lessons learned -- NREL Village Power Program

    Energy Technology Data Exchange (ETDEWEB)

    Flowers, L.

    1998-07-01

    In 1993, a workshop was convened at the National Renewable Energy Laboratory (NREL) to discuss the issues of applying renewable energy in a sustainable manner to international rural development. One of the summary recommendations was that NREL could assist in the renewable energy for rural electrification effort by developing and supplying six related activities: resource assessment, comparative analysis and modeling, performance monitoring and analysis, pilot project development, internet-based project data, communications, and training. In response to this recommendation, NREL launched its Village Power Program consisting of these activities that cut across NREL technologies and disciplines. Currently NREL is active in 20 countries, with pilot projects in 12 of those countries. At this time the technologies include photovoltaics, wind, biomass, and hybrids. The rural applications include home lighting and communications, water pumping, schools and health posts, battery charging stations, ecotourism, and village systems. These pilot projects are central to the renewable energy village power development through the demonstration of three aspects critical to replication and implementation of the projects on a significant scale. The three aspects are technical functionality, economic competitiveness, and institutional sustainability. It is important to note that the pilot projects from which NREL's experience has been gained were funded and, in many cases, developed by other organizations and agencies. NREL's role has been one of technical assistance or project management or both. The purpose of this paper is to describe the lessons NREL staff has gleaned from their participation in the various pilot projects. The author hopes that these lessons will help the Renewable Energy-Based Rural Electrification (RERE) community in implementing sustainable projects that lead to replication.

  20. Optimal sizing of battery storage for stand-alone hybrid (photo-voltaic + diesel) power systems

    Science.gov (United States)

    Shaahid, S. M.; Elhadidy, M. A.

    2005-09-01

    An important element of hybrid photo- voltaic(PV) + diesel sytem is battery storage. Size of battery storage plays a role in optimum operation of the hybrid system. Emphasis needs to be placed on this issue. In this perspective, hourly solar radiation data, for the period 1986 93 recorded at Dhahran, Saudi Arabia, have been analyzed to investigate the optimum size of battery storage capacity for hybrid (PV + diesel) power systems. Various sizing configurations have been simulated. The monthly average daily values of solar global radiation range from 3.61 to 7.96kWh/m2. As a case study, hybrid systems considered in the present analysis consist of 225m2 PV array area (panels/modules) supplemented with battery storage unit and diesel backup generators (to meet the load requirements of a typical residential building with annual electrical energy demand of 35,200kWh). The monthly average energy generated from the aforementioned hybrid system for different scenarios has been presented. More importantly, the study explores the influence of variation of battery storage capacity on hybrid power generation. The results exhibit a trade-off between size of the storage capacity and diesel power to be generated to cope with annual load distribution. Concurrently, the energy to be generated from the diesel generator and the number of operational hours of the diesel system to meet the load demand have been also addressed.The study shows that for optimum operation of diesel system, storage capacity equivalent to 12 18h of maximum monthly average hourly demand need to be used. It has been found that in the absence of battery bank, ˜58% of the load needs to be provided by the diesel system. However, use of 12h of battery storage (autonomy) reduces diesel energy generation by ˜49% and the number of hours of operation of the diesel system get reduced by about ˜82%. The findings of this study can be employed as a tool for sizing of battery storage for PV/diesel systems for other

  1. Development of a new lower hybrid antenna module using a poloidal power divider

    Energy Technology Data Exchange (ETDEWEB)

    Maebara, Sunao; Seki, Masami; Suganuma, Kazuaki [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment] [and others

    1996-07-01

    The antenna using poloidal power divider is an effective method for simplification of Lower Hybrid Current Drive (LHCD) antenna system. This method should allow to reduce the power density in the antenna while maintaining a good flexibility of N{sub parallel} spectrum of waves. For this purpose, three types of poloidal power divider which split the power in three, and the 3 x 6 multi-junction module were developed. r.f. properties and outgassing of these components were evaluated using the CEA Cadarache RF Test Facility. A good power dividing ratio of 33 {+-} 4% was obtained for each of these poloidal dividers, and the reflection coefficient was lower value than 1.5%. For the 3 x 6 multi-junction, reflection coefficient was less than 1.3% and r.f. losses lower than 1.0% were measured. On the other hand, it was found in the scattering matrix analysis that reflection coefficient at plasma has to be less than a few % in order to operate these components under available conditions. In combination with two poloidal power dividers connected to the 3 x 6 multi-junction module, quasi stationary operation for r.f. injection time of 1000 sec at 300 kW was demonstrated under water cooling. In this case, it was found that the outgassing rate is in the lower range of 10{sup -7}Pam{sup 3}s{sup -1}m{sup -2} within the maximum module temperature of {approx}100degC. This report describes the experimental and analytical results of a new lower hybrid (LH) antenna module using the poloidal power divider. (author)

  2. A Hybrid Data Compression Scheme for Power Reduction in Wireless Sensors for IoT.

    Science.gov (United States)

    Deepu, Chacko John; Heng, Chun-Huat; Lian, Yong

    2017-04-01

    This paper presents a novel data compression and transmission scheme for power reduction in Internet-of-Things (IoT) enabled wireless sensors. In the proposed scheme, data is compressed with both lossy and lossless techniques, so as to enable hybrid transmission mode, support adaptive data rate selection and save power in wireless transmission. Applying the method to electrocardiogram (ECG), the data is first compressed using a lossy compression technique with a high compression ratio (CR). The residual error between the original data and the decompressed lossy data is preserved using entropy coding, enabling a lossless restoration of the original data when required. Average CR of 2.1 × and 7.8 × were achieved for lossless and lossy compression respectively with MIT/BIH database. The power reduction is demonstrated using a Bluetooth transceiver and is found to be reduced to 18% for lossy and 53% for lossless transmission respectively. Options for hybrid transmission mode, adaptive rate selection and system level power reduction make the proposed scheme attractive for IoT wireless sensors in healthcare applications.

  3. Ergodynamics in the Reliability of Power Plant Operators and Prospective Hybrid Intelligence Systems.

    Science.gov (United States)

    Venda; Chachko

    1996-01-01

    Based on ergodynamics and the hybrid intelligence theory, an analysis of the nuclear power plant operator's performance is given at the levels of strategies, tactics, and actions. Special attention is paid to the strategies used in the course of severe accidents at nuclear power plants. Data from Ukrainian and Russian power plants and training centres, and from accidents around the world were collected and processed. It is shown that in an emergency it is essential for the human operator to be flexible. This flexibility includes two main training and personal factors: a large set of strategies and tactics the operator manages to use, and quick transformations between the strategies (tactics). It was also found that some emergency tasks are too complicated: They require simultaneous use of different strategies, with time strictly limited by nuclear power plant dynamics. Those tasks cannot be successfully solved by any individual operator. Hybrid intelligence systems involving different specialists should be used in those cases in order to avoid failures in emergency problem solving and macroergonomic organizational design.

  4. Conceptual Design of Low Fusion Power Hybrid System for Waste Transmutation

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Seong Hee; Kim, Myung Hyun [Kyung Hee University, Yongin (Korea, Republic of)

    2016-10-15

    DRUP (Direct Reuse of Used PWR) fuel has same process with DUPIC (Direct Use of spent PWR fuel Into CANDU reactor). There are 2 big benefits by using DRUP fuel in Hybrid system. One is fissile production during operating period. Required power is decreased by fissile production from DRUP fuel. When the fusion power is reduced, integrity of structure materials is not significantly weakened due to reduction of 14.1MeV high energy neutrons. In addition, required amount of tritium for self-sufficiency TBR (Tritium Breeding Ratio ≥ 1.1) is decreased. Therefore, it is possible to further loading the SNF as much as the amount of lithium decreased. It is effective in transmutation. The other one is that DRUP fuel is also SNF. Therefore, using DRUP fuel is reusing of SNF, as a result it makes reduction of SNF from PWR. However, thermal neutron system is suitable for using DRUP fuel compared to fast neutron system. Therefore, transmutation zone designed (U-TRU)Zr fuel and fissile production zone designed DRUP fuel are separated in this study. In this paper, using DRUP fuel for low fusion power in hybrid system is suggested. Fusion power is decreased by using DRUP fuel. As a result, TBR is satisfied design condition despite of using natural lithium. In addition, not only (U-TRU)Zr fuel but also DRUP fuel are transmuted.

  5. Solid Oxide Fuel Cell/Gas Turbine Hybrid Cycle Technology for Auxiliary Aerospace Power

    Science.gov (United States)

    Steffen, Christopher J., Jr.; Freeh, Joshua E.; Larosiliere, Louis M.

    2005-01-01

    A notional 440 kW auxiliary power unit has been developed for 300 passenger commercial transport aircraft in 2015AD. A hybrid engine using solid-oxide fuel cell stacks and a gas turbine bottoming cycle has been considered. Steady-state performance analysis during cruise operation has been presented. Trades between performance efficiency and system mass were conducted with system specific energy as the discriminator. Fuel cell performance was examined with an area specific resistance. The ratio of fuel cell versus turbine power was explored through variable fuel utilization. Area specific resistance, fuel utilization, and mission length had interacting effects upon system specific energy. During cruise operation, the simple cycle fuel cell/gas turbine hybrid was not able to outperform current turbine-driven generators for system specific energy, despite a significant improvement in system efficiency. This was due in part to the increased mass of the hybrid engine, and the increased water flow required for on-board fuel reformation. Two planar, anode-supported cell design concepts were considered. Designs that seek to minimize the metallic interconnect layer mass were seen to have a large effect upon the system mass estimates.

  6. Bio-inspired, Moisture-Powered Hybrid Carbon Nanotube Yarn Muscles

    Science.gov (United States)

    Kim, Shi Hyeong; Kwon, Cheong Hoon; Park, Karam; Mun, Tae Jin; Lepró, Xavier; Baughman, Ray H.; Spinks, Geoffrey M.; Kim, Seon Jeong

    2016-03-01

    Hygromorph artificial muscles are attractive as self-powered actuators driven by moisture from the ambient environment. Previously reported hygromorph muscles have been largely limited to bending or torsional motions or as tensile actuators with low work and energy densities. Herein, we developed a hybrid yarn artificial muscle with a unique coiled and wrinkled structure, which can be actuated by either changing relative humidity or contact with water. The muscle provides a large tensile stroke (up to 78%) and a high maximum gravimetric work capacity during contraction (2.17 kJ kg-1), which is over 50 times that of the same weight human muscle and 5.5 times higher than for the same weight spider silk, which is the previous record holder for a moisture driven muscle. We demonstrate an automatic ventilation system that is operated by the tensile actuation of the hybrid muscles caused by dew condensing on the hybrid yarn. This self-powered humidity-controlled ventilation system could be adapted to automatically control the desired relative humidity of an enclosed space.

  7. Optimal configuration assessments of hybrid renewable power supply for rural healthcare facilities

    Directory of Open Access Journals (Sweden)

    Lanre Olatomiwa

    2016-11-01

    Full Text Available This paper assessed optimal configurations of hybrid renewable system for rural health clinic (RHC application in three grid-unconnected rural villages in Nigeria. The RHC consist of an emergency room, consulting room, nurse/injection room, male ward, female ward, a delivery room and a laboratory with average total daily energy consumption of 15.5 kWh and 2.75 kW peak demand. The assessment of configurations that optimally meet the daily load demand with zero loss of power supply probability (LPSP was carried out using HOMER software, by considering three energy resources; photovoltaic (PV, wind and diesel with battery energy storage. The result obtained revealed hybrid PV/wind/diesel/battery system as the most cost-effective configuration for powering rural health clinic in both Maiduguri and Enugu sites, while that of Iseyin site was found to be hybrid PV/diesel/battery system. In all the sites, the selected optimal configuration is far better than the conventional diesel stand-alone system in terms of cost and emission reduction.

  8. Dual communication system for RAMEA's remote hybrid power system

    Energy Technology Data Exchange (ETDEWEB)

    Acevedo, J.F.; Iqbal, M.T. [Memorial Univ. of Newfoundland, St. John' s, NL (Canada). Faculty of Engineering and Applied Science

    2010-07-01

    This PowerPoint presentation described a dual communication system designed for a wind-hydrogen-diesel hybrid system located on an island off the coast of Newfoundland. The hybrid system was comprised of a 2.775 MW diesel plant; six 65 kW wind turbines; and three 100 kW wind turbines. The hybrid power infrastructure was installed in the isolated community to reduce dependence on diesel fuel as well as to reduce greenhouse gas (GHG) emissions. The DAST remote communication system included wireless remote supervision and control, and functional frequency in which to operate in the free license electromagnetic spectrum. The communication system was compared with several other types of communications systems. Tests showed that the DAST system successfully communicated with the control room and recorded data on a terminal computer via Ethernet. The wireless and PLC transmission showed no instability and were adequately synchronized. High pass filter performance results and analog and digital scan rate data were presented. Future research will concentrate on developing interfacing prototypes with a centralized supervisory controller. The transformer's bypass will incorporated into the system to eliminate transformer constraints. tabs., figs.

  9. Mode transition coordinated control for a compound power-split hybrid car

    Science.gov (United States)

    Wang, Chen; Zhao, Zhiguo; Zhang, Tong; Li, Mengna

    2017-03-01

    With a compound power-split transmission directly connected to the engine in hybrid cars, dramatic fluctuations in engine output torque result in noticeable jerks when the car is in mode transition from electric drive mode to hybrid drive mode. This study designed a mode transition coordinated control strategy, and verified that strategy's effectiveness with both simulations and experiments. Firstly, the mode transition process was analyzed, and ride comfort issues during the mode transition process were demonstrated. Secondly, engine ripple torque was modeled using the measured cylinder pumping pressure when the engine was not in operation. The complete dynamic plant model of the power-split hybrid car was deduced, and its effectiveness was validated by a comparison of experimental and simulation results. Thirdly, a coordinated control strategy was designed to determine the desired engine torque, motor torque, and the moment of fuel injection. Active damping control with two degrees of freedom, based on reference output shaft speed estimation, was designed to mitigate driveline speed oscillations. Carrier torque estimation based on transmission kinematics and dynamics was used to suppress torque disturbance during engine cranking. The simulation and experimental results indicate that the proposed strategy effectively suppressed vehicle jerks and improved ride comfort during mode transition.

  10. Energy Management of an Off-Grid Hybrid Power Plant with Multiple Energy Storage Systems

    Directory of Open Access Journals (Sweden)

    Laura Tribioli

    2016-08-01

    Full Text Available In this paper, an off-grid hybrid power plant with multiple storage systems for an artificial island is designed and two possible strategies for the management of the stored energy are proposed. Renewable power sources (wind/solar technologies are used as primary power suppliers. A lead-acid battery pack (BAT and a reversible polymer electrolyte fuel cell are employed to fulfill the power demand and to absorb extra power. The reversible fuel cell allows reducing costs and occupied space and the fuel cell can be fed by the pure hydrogen produced by means of its reversible operation as an electrolyzer. A diesel engine is employed as backup system. While HOMER Pro® has been employed for a full-factorial-based optimization of the sizes of the renewable sources and the BAT, Matlab/Simulink® has been later used for simulating the plant operation and compare two possible power management control strategies. For the reversible fuel cell sizing, a sensitivity analysis has been carried out varying stack and hydrogen tank sizes. The final choice for plant configuration and power management control strategy has been made on the basis of a comparative analysis of the results, aimed at minimizing fossil fuel consumption and CO2 emissions, battery aging rate and at maximizing the power plant overall efficiency. The obtained results demonstrate the possibility of realizing a renewable power plant, able to match the needs of electrical power in a remote area, by achieving a good integration of different energy sources and facing the intermittent nature of renewable power sources, with very low use of fossil fuels.

  11. An Operating Method Using Prediction of Photovoltaic Power for a Photovoltaic-Diesel Hybrid Power Generation System

    Science.gov (United States)

    Yamamoto, Shigehiro; Sumi, Kazuyoshi; Nishikawa, Eiichi; Hashimoto, Takeshi

    This paper describes a novel operating method using prediction of photovoltaic (PV) power for a photovoltaic-diesel hybrid power generation system. The system is composed of a PV array, a storage battery, a bi-directional inverter and a diesel engine generator (DG). The proposed method enables the system to save fuel consumption by using PV energy effectively, reducing charge and discharge energy of the storage battery, and avoiding low-load operation of the DG. The PV power is simply predicted from a theoretical equation of solar radiation and the observed PV energy for a constant time before the prediction. The amount of fuel consumption of the proposed method is compared with that of other methods by a simulation based on measurement data of the PV power at an actual PV generation system for one year. The simulation results indicate that the amount of fuel consumption of the proposed method is smaller than that of any other methods, and is close to that of the ideal operation of the DG.

  12. A Novel Hybrid Method for Short-Term Power Load Forecasting

    Directory of Open Access Journals (Sweden)

    Huang Yuansheng

    2016-01-01

    Full Text Available Influenced by many uncertain and random factors, nonstationary, nonlinearity, and time-variety appear in power load series, which is difficult to forecast accurately. Aiming at locating these issues of power load forecasting, an innovative hybrid method is proposed to forecast power load in this paper. Firstly, ensemble empirical mode decomposition (EEMD is used to decompose the power load series into a series of independent intrinsic mode functions (IMFs and a residual term. Secondly, genetic algorithm (GA is then applied to determine the best weights of each IMF and the residual term named ensemble empirical mode decomposition based on weight (WEEMD. Thirdly, least square support vector machine (LSSVM and nonparametric generalized autoregressive conditional heteroscedasticity (NPGARCH are employed to forecast the subseries, respectively, based on the characteristics of power load series. Finally, the forecasted power load of each component is summed as the final forecasted result of power load. Compared with other methods, the forecasting results of this proposed model applied to the electricity market of Pennsylvania-New Jersey-Maryland (PJM indicate that the proposed model outperforms other models.

  13. Simulation of a Pneumatic Hybrid Powertrain with VVT in GT-Power and Comparison with Experimental Data

    OpenAIRE

    Trajkovic, Sasa; Tunestål, Per; Johansson, Bengt

    2009-01-01

    In the study presented in this paper, experimental data from a pneumatic hybrid has been compared to the results from a simulation of the engine in GT-Power. The engine in question is a single-cylinder Scania D12 diesel engine, which has been converted to work as a pneumatic hybrid. The base engine model, provided by Scania, is made in GT-Power and it is based on the same engine configuration as the one used during real engine testing. During pneumatic hybrid operation the engine can be us...

  14. Solar thermal power & gas turbine hybrid design with molten salt storage tank

    Science.gov (United States)

    Martín, Fernando; Wiesenberg, Ralf; Santana, Domingo

    2017-06-01

    Taking into consideration the need to decelerate the global climatic change, power generation has to shift from burning fossil fuel to renewable energy source in short medium period of time. In this work, we are presenting a new model of a solar-gas natural hybrid power cycle with the main aim of decoupling the solar generation system from the gas turbine system. The objective is to have high solar power contribution compared to conventional ISCC plants [2], producing firm and dispatchable electricity at the same time. The decoupling is motivated by the low solar contribution reached by the ISCC, which is technically limited to maximum of 15%, [4]. In our case, we have implemented a solar tower with molten salts as working fluid. Central receiver systems get higher performance than others systems, like parabolic trough technology [1], due to the higher temperature achieved in the heat transferred fluid HTF, close to 560°C.

  15. Zero Power Levitation Control of Hybrid Electro-Magnetic Levitation System by Load Observer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Youn Hyun; Lee, Ju [Hanyang University, Seoul (Korea)

    2001-06-01

    This paper introduces the scheme that improve the control performance of electromagnetic levitation system with zero power controller. Magnetic levitation is used widely, but the electromagnetic force has nonlinear characteristics because it is proportioned to a square of the magnetic flux density and it is in inverse proportion to a square of the air gap. So, it is complicate and difficult to control the electromagnetic force. Besides, it is more difficult to control if the equivalent gap is unknown in case of zero power control. Therefore, this paper proposed the hybrid electro-magnetic levitation control method in which the variable load is estimated by using a load observer and its system is controlled at a new zero power equilibrium air gap position. Also it is confirmed that the proposed control method improve the control performance through simulation and experiment. (author). 10 refs., 17 figs., 1 tab.

  16. Control strategy of fuel cell/supercapacitors hybrid power sources for electric vehicle

    Energy Technology Data Exchange (ETDEWEB)

    Thounthong, Phatiphat; Raeel, Stephane; Davat, Bernard [Institut National Polytechnique de Lorraine (INPL), GREEN, CNRS (UMR 7037) 2, Avenue de la Foret de Haye, 54516 Vandoeuvre-les-Nancy (France)

    2006-07-14

    This paper presents a control principle for utilizing PEM fuel cell as main power source and supercapacitors as auxiliary power source for electric vehicle applications. The strategy is based on dc link voltage regulation, and fuel cell is simply operating in almost steady state conditions in order to minimize the mechanical stresses of fuel cell and to ensure a good synchronization between fuel flow and fuel cell current. Supercapacitors are functioning during transient energy delivery or transient energy recovery. To authenticate control algorithms, the system structure is realized by analogical current loops and digital voltage loops (dSPACE). The experimental results with a 500W PEM fuel cell point out the fuel cell starvation problem when operating with dynamic load, and also confirm that the supercapacitor can improve system performance for hybrid power sources. (author)

  17. Shunt hybrid active power filter under nonideal voltage based on fuzzy logic controller

    Science.gov (United States)

    Dey, Papan; Mekhilef, Saad

    2016-09-01

    In this paper, a synchronous reference frame (SRF) method based on a modified phase lock loop (PLL) circuit is developed for a three-phase four-wire shunt hybrid active power filter (APF). Its performance is analysed under unbalanced grid conditions. The dominant lower order harmonics as well as reactive power can be compensated by the passive elements, whereas the active part mitigates the remaining distortions and improves the power quality. As different control methods show contradictory performance, fuzzy logic controller is considered here for DC-link voltage regulation of the inverter. Extensive simulations of the proposed technique are carried out in a MATLAB-SIMULINK environment. A laboratory prototype has been built on dSPACE1104 platform to verify the feasibility of the suggested SHAPF controller. The simulation and experimental results validate the effectiveness of the proposed technique.

  18. Solution of wind integrated thermal generation system for environmental optimal power flow using hybrid algorithm

    Directory of Open Access Journals (Sweden)

    Ambarish Panda

    2016-09-01

    Full Text Available A new evolutionary hybrid algorithm (HA has been proposed in this work for environmental optimal power flow (EOPF problem. The EOPF problem has been formulated in a nonlinear constrained multi objective optimization framework. Considering the intermittency of available wind power a cost model of the wind and thermal generation system is developed. Suitably formed objective function considering the operational cost, cost of emission, real power loss and cost of installation of FACTS devices for maintaining a stable voltage in the system has been optimized with HA and compared with particle swarm optimization algorithm (PSOA to prove its effectiveness. All the simulations are carried out in MATLAB/SIMULINK environment taking IEEE30 bus as the test system.

  19. Real-time optimization power-split strategy for hybrid electric vehicles

    Institute of Scientific and Technical Information of China (English)

    XIA ChaoYing; ZHANG Cong

    2016-01-01

    Energy management strategies based on optimal control theory can achieve minimum fuel consumption for hybrid electric vehicles,but the requirement for driving cycles known in prior leads to a real-time problem.A real-time optimization power-split strategy is proposed based on linear quadratic optimal control.The battery state of charge sustainability and fuel economy are ensured by designing a quadratic performance index combined with two rules.The engine power and motor power of this strategy are calculated in real-time based on current system state and command,and not related to future driving conditions.The simulation results in ADVISOR demonstrate that,under the conditions of various driving cycles,road slopes and vehicle parameters,the proposed strategy significantly improves fuel economy,which is very close to that of the optimal control based on Pontryagin's minimum principle,and greatly reduces computation complexity.

  20. Prospects for the application of GaN power devices in hybrid electric vehicle drive systems

    Science.gov (United States)

    Su, Ming; Chen, Chingchi; Rajan, Siddharth

    2013-07-01

    GaN, a wide bandgap semiconductor successfully implemented in optical and high-speed electronic devices, has gained momentum in recent years for power electronics applications. Along with rapid progress in material and device processing technologies, high-voltage transistors over 600 V have been reported by a number of teams worldwide. These advances make GaN highly attractive for the growing market of electrified vehicles, which currently employ bipolar silicon devices in the 600-1200 V class for the traction inverter. However, to capture this billion-dollar power market, GaN has to compete with existing IGBT products and deliver higher performance at comparable or lower cost. This paper reviews key achievements made by the GaN semiconductor industry, requirements of the automotive electric drive system and remaining challenges for GaN power devices to fit in the inverter application of hybrid vehicles.

  1. SVC Planning in Large–scale Power Systems via a Hybrid Optimization Method

    DEFF Research Database (Denmark)

    Yang, Guang ya; Majumder, Rajat; Xu, Zhao

    2009-01-01

    The research on allocation of FACTS devices has attracted quite a lot interests from various aspects. In this paper, a hybrid model is proposed to optimise the number, location as well as the parameter settings of static Var compensator (SVC) deployed in large–scale power systems. The model utili...... a candidate solution pool. Then in the second stage, the candidates are presented to a linear planning model to investigate the system optimal loadability, hence the optimal solution for SVC planning can be achieved. The method is presented to IEEE 300–bus system....... utilises the result of vulnerability assessment for determining the candidate locations. A hybrid optimisation method including two stages is proposed to find out the optimal solution of SVC in large– scale planning problem. In the first stage, a conventional genetic algorithm (GA) is exploited to generate...

  2. Study of molten carbonate fuel cell—microturbine hybrid power cycles

    Science.gov (United States)

    Jurado, Francisco

    The interaction realized by fuel cell—microturbine hybrids derive primarily from using the rejected thermal energy and combustion of residual fuel from a fuel cell in driving the gas turbine. This leveraging of thermal energy makes the high temperature molten carbonate fuel cells (MCFCs) ideal candidates for hybrid systems. Use of a recuperator contributes to thermal efficiency by transferring heat from the gas turbine exhaust to the fuel and air used in the system. Traditional control design approaches, consider a fixed operating point in the hope that the resulting controller is robust enough to stabilize the system for different operating conditions. On the other hand, adaptive control incorporates the time-varying dynamical properties of the model (a new value of gas composition) and considers the disturbances acting at the plant (load power variation).

  3. Hybrid Configuration of Darrieus and Savonius Rotors for Stand-alone Power Systems

    Science.gov (United States)

    Wakui, Tetsuya; Tanzawa, Yoshiaki; Hashizume, Takumi; Nagao, Toshio

    The suitable hybrid configuration of Darrieus lift-type and Savonius drag-type rotors for stand-alone wind turbine-generator systems is discussed using our dynamic simulation model. Two types of hybrid configurations are taken up: Type-A installs the Savonius rotor inside the Darrieus rotor and Type-B installs the Savonius rotor outside the Darrieus rotor. The computed results of the output characteristics and the dynamic behaviors of the system operated at the maximum power coefficient points show that Type-A, which has fine operating behavior to wind speed changes and can be compactly designed because of a shorter rotational shaft, is an effective way for self-controlled stand-alone small-scale systems.

  4. Thermo-economic modeling of an indirectly coupled solid oxide fuel cell/gas turbine hybrid power plant

    Energy Technology Data Exchange (ETDEWEB)

    Cheddie, Denver F. [Center for Energy Studies, University of Trinidad and Tobago, Point Lisas Campus, Esperanza Road, Brechin Castle, Couva (Trinidad and Tobago); Tobago; Murray, Renique [Natural Gas Institute of the Americas, University of Trinidad and Tobago, Point Lisas Campus, Esperanza Road, Brechin Castle, Couva (Trinidad and Tobago); Tobago

    2010-12-15

    Power generation using gas turbine (GT) power plants operating on the Brayton cycle suffers from low efficiencies, resulting in poor fuel to power conversion. A solid oxide fuel cell (SOFC) is proposed for integration into a 10 MW gas turbine power plant, operating at 30% efficiency, in order to improve system efficiencies and economics. The SOFC system is indirectly coupled to the gas turbine power plant, paying careful attention to minimize the disruption to the GT operation. A thermo-economic model is developed for the hybrid power plant, and predicts an optimized power output of 20.6 MW at 49.9% efficiency. The model also predicts a break-even per-unit energy cost of USD 4.65 cents kWh{sup -1} for the hybrid system based on futuristic mass generation SOFC costs. This shows that SOFCs may be indirectly integrated into existing GT power systems to improve their thermodynamic and economic performance. (author)

  5. Multi-objective optimization for hybrid fuel cells power system under uncertainty

    Science.gov (United States)

    Subramanyan, Karthik; Diwekar, Urmila M.; Goyal, Amit

    One of the major applications of fuel cells is as onsite stationary electric power plants. Several types of configurations have been hypothesized and tested for these kinds of applications at the conceptual level but hybrid power plants are one of the most efficient. These are designs that combine a fuel cell cycle with other thermodynamic cycles to provide higher efficiency. Generally, the heat rejected by the fuel cell at a higher temperature is used in a bottoming cycle to generate steam. In this work we are considering a conceptual design of a solid oxide fuel cell-proton exchange membrane (SOFC-PEM) fuel cell hybrid power plant [R. Geisbrecht, Compact Electrochemical Reformer Based on SOFC Technology, AIChE Spring National Meeting, Atlanta, GA, 2000] in which the high temperature SOFC fuel cell acts both as electricity producer and fuel reformer for the low temperature PEM fuel cell (PEMFC). The exhaust from the PEM fuel cell goes to a waste hydrogen burner and heat recovery steam generator that produces steam for further utilizations. Optimizing this conceptual design involves consideration of a number of objectives. The process should have low pollutant emissions as well as cost competitive with the existing technology. The solution of a multi-objective optimization problem is not a single solution but a complete non-dominated or Pareto set, which includes the alternatives representing potential compromise solutions among the objectives. This makes a range of choice available to decision makers and provides them with the trade-off information among the multiple objectives effectively. This paper presents the optimal trade-off design solutions or the Pareto set for this hybrid power plant through a multi-objective optimization framework. This hybrid technology is new and the system level models used for fuel cells performance have significant uncertainties in them. In this paper, we characterize these uncertainties and study the effect of these uncertainties

  6. Adaptive Passivity-Based Control of PEM Fuel Cell/Battery Hybrid Power Source for Stand-Alone Applications

    Directory of Open Access Journals (Sweden)

    KALANTAR, A.

    2010-11-01

    Full Text Available In this paper, a DC hybrid power source composed of PEM fuel cell as main source, Li-ion battery storage as transient power source and their power electronic interfacing is modelled based on Euler-Lagrange framework. Subsequently, adaptive passivity-based controllers are synthesized using the energy shaping and damping injection technique. Local asymptotic stability is insured as well. In addition, the power management system is designed in order to manage power flow between components. Evaluation of the proposed system and simulation of the hybrid system are accomplished using MATLAB/Simulink. Afterwards, linear PI controllers are provided for the purpose of comparison with proposed controllers responses. The results show that the outputs of hybrid system based on adaptive passivity-based controllers have a good tracking response, low overshoot, short settling time and zero steady-state error. The comparison of results demonstrates the robustness of the proposed controllers for reference DC voltage and resistive load changes.

  7. Improvement of Transient Stability in a Hybrid Power Multi-System Using a Designed NIDC (Novel Intelligent Damping Controller

    Directory of Open Access Journals (Sweden)

    Ting-Chia Ou

    2017-04-01

    Full Text Available This paper endeavors to apply a novel intelligent damping controller (NIDC for the static synchronous compensator (STATCOM to reduce the power fluctuations, voltage support and damping in a hybrid power multi-system. In this paper, we discuss the integration of an offshore wind farm (OWF and a seashore wave power farm (SWPF via a high-voltage, alternating current (HVAC electric power transmission line that connects the STATCOM and the 12-bus hybrid power multi-system. The hybrid multi-system consists of a battery energy storage system (BESS and a micro-turbine generation (MTG. The proposed NIDC consists of a designed proportional–integral–derivative (PID linear controller, an adaptive critic network and a proposed functional link-based novel recurrent fuzzy neural network (FLNRFNN. Test results show that the proposed controller can achieve better damping characteristics and effectively stabilize the network under unstable conditions.

  8. Feasibility study on the demonstrative test on the hybrid mini hydroelectric power generation technology. 2; Hybrid gata mini suiryoku hatsuden gijutsu ni kakawaru jissho shiken kanosei chosa. 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    A study was made for the purpose of electrification of unelectrified zones of the mountainous areas in developing countries using extremely small hydroelectric power facilities. The target for this project is a development of a micro hydroelectric power system with a size of about 5kW, which is estimated regarding that 1 village has 80 houses and each house needs electricity of 60W. In the study, the low-head system using a weir of irrigation channels in Subang pref. of West Java state was selected by the evaluation of access, stability of flow rate, natural conditions, etc. The hydroelectric power plant is of a flow-in method in which water is taken from the left bank and is injected/discharged to the downstream of the left bank. As the hybrid complementary power source, hybrid battery with a two-hour charging time at peak and a capacity of 3.5kWh was considered. When estimating the construction cost of the hybrid micro hydroelectric power system and equalizing by durable years, the operational cost per kW is 15 times higher than the benefits which local people receive. It was judged to be difficult to say that the micro hydroelectric power system is economically feasible. It was predicted that the financial profit during the demonstrative test is good, according to a trial calculation of income from power rates and the operational cost. 18 refs., 90 figs., 53 tabs.

  9. Self-powered pH sensor based on a flexible organic-inorganic hybrid composite nanogenerator.

    Science.gov (United States)

    Saravanakumar, Balasubramaniam; Soyoon, Shin; Kim, Sang-Jae

    2014-08-27

    In this study, we developed an innovative, flexible, organic-inorganic hybrid composite nanogenerator, which was used to drive a self-powered microwire-based pH sensor. The hybrid composite nanogenerator was fabricated using ZnO nanowire and piezoelectric polymer poly(vinylidene fluoride), through a simple, inexpensive solution-casting technique. The fabricated hybrid composite nanogenerator delivered a maximum open-circuit voltage of 6.9 V and a short-circuit current of 0.96 μA, with an output power of 6.624 μW under uniaxial compression. This high-performance, electric poling free composite nanogenerator opens up the possibility of industrial-scale fabrication. The hybrid nanogenerator demonstrated its ability to drive five green LEDs simultaneously, without using an energy-storage device. Additionally, we constructed a self-powered pH sensor, using a ZnO microwire powered with our hybrid nanogenerator. The output voltage varied according to changes in the pH level. This study demonstrates the feasibility of using a hybrid nanogenerator as a self-powered device that can be extended for use as a biosensor for environmental monitoring and/or as a smart, wearable, vibration sensor in future applications.

  10. A Hybrid Search Algorithm for Midterm Optimal Scheduling of Thermal Power Plants

    Directory of Open Access Journals (Sweden)

    Shengli Liao

    2015-01-01

    Full Text Available A hybrid search algorithm consisting of three stages is presented to solve the midterm schedule for thermal power plants (MTSFTPP problem, where the primary objective is to achieve equal accumulated operating hours of installed capacity (EAOHIC for all thermal power plants during the selected period. First, feasible spaces are produced and narrowed based on constraints on the number of units and power load factors. Second, an initial feasible solution is obtained by a heuristic method that considers operating times and boundary conditions. Finally, the progressive optimality algorithm (POA, which we refer to as the vertical search algorithm (VSA, is used to solve the MTSFTPP problem. A method for avoiding convergence to a local minimum, called the lateral search algorithm (LSA, is presented. The LSA provides an updated solution that is used as a new feasible starting point for the next search in the VSA. The combination of the LSA and the VSA is referred to as the hybrid search algorithm (HSA, which is simple and converges quickly to the global minimum. The results of two case studies show that the algorithm is very effective in solving the MTSFTPP problem accurately and in real time.

  11. Survey of technology for hybrid vehicle auxiliary power units. Interim report, April 1994-June 1995

    Energy Technology Data Exchange (ETDEWEB)

    Widener, S.K.

    1995-10-01

    The state-of-the-art of heat engines for use as auxiliary power units in hybrid vehicles is surveyed. The study considers reciprocating or rotary heat engines, excluding gas turbines and fuel cells. The relative merits of various engine-generator concepts are compared. The concepts are ranked according to criteria tailored for a series-type hybrid drive. The two top APU concepts were the free-piston engine/linear generator (FPELG) and the Wankel rotary` engine. The FPELG is highly ranked primarily because of thermal efficiency cost, producibility. reliability, and transient response advantages; it is a high risk concept because of unproven technology. The Wankel engine is proven. with high power density, low cost and low noise. Four additional competitive concepts include two-stroke spark-ignition engine. two-stroke gas generator with turboalternator, free-piston engine gas generator with turboalternator, and homogeneous charge compression ignition engine. This study recommends additional work, including cycle simulation development and preliminary design to better quantify thermal efficiency and power density. Auxiliary concepts were also considered, including two which warrant further study: electrically actuated valves, and lean turndown of a normally stoichiometric engine. These concepts should be evaluated by retrofitting to existing engines.

  12. Synthetically Control of a Hybrid PV/FC/SC Power System for Stand-Alone Applications

    Directory of Open Access Journals (Sweden)

    Dakang Zhu

    2013-02-01

    Full Text Available In this study, a simple and practical control scheme for power assignment and load-following of a Hybrid Power System (HPS is proposed. The system consists of Photovoltaic (PV, Fuel Cell (FC, Super-Capacitor (SC, dc load, ac load and different kinds of converters. PV is chosen as a prior source, which normally operates in Maximum Power Point Tracking (MPPT mode. In order to achieve 24 h power supply under various natural conditions, FC is used as a backup source to provide the power deficit between solar generation and load demand. Taking the slow FC system dynamics into account, FC power slope has been limited to protect FC from fuel starvation, whereas SC is chosen to satisfy the requirement of the sudden load and solar radiation changes. Besides, a V/f controller is designed to meet ac load demand, while keeping the voltage and frequency within an acceptable range. All the details of this study, including system structure, control diagrams and MATLAB simulation results, are presented.

  13. Performance of a 60 F carbon nanotubes-based supercapacitor for hybrid power sources

    Institute of Scientific and Technical Information of China (English)

    Xiaofeng Wang; Dianbo Ruan; Zheng You; Yiqiang Lu; Qiqian Sha

    2005-01-01

    A supercapacitor based on charge storage at the interface between a high surface area carbon nanotube electrode and a LiClO4/PC electrolyte was assembled. The performance of the capacitor depends on not only the material used in the cell but also the construction of the cell. From a constant charge-discharge test, the capacitance of 60 F was obtained. The performance of the power power supercapacitor were demonstrated with a cell of the maximum operating voltage of 2.5 V. A hybrid power source consisting of a lithium ionic battery and the 60 F supercapacitor was demonstrated to power successfully a simulated power load encountered in GSM portable communication equipment. The addition of the supercapacitor to the power train of a cellular phone results in significantly more energy from the battery being used by the load. The experiments indicate that more than 33.8% energy is utilized by load and less stored energy is dissipated within the battery for each charge-discharge cycle.

  14. PSO based Optimal Power Flow with Hybrid Distributed Generators and UPFC

    Directory of Open Access Journals (Sweden)

    S.G. Bharathi dasan

    2012-09-01

    Full Text Available Distributed Generation (DG is a small source of electric power conversion from nonconventionalenergy sources and Hybrid DGs is often the most cost-effective and reliable way toproduce power. Optimal Power flow (OPF study is conducted on a power system to achieve one of the following objectives: cost/loss minimization or Available transfer capability (ATCcalculation in a deregulated environment. The optimality of control variables would definitely change with respect to the location, quantity and combination of power injection by DGs. On the other hand, FACTS controllers are effective in utilizing the existing transmission network whichis very important especially in a deregulated system. Unified Power flow controller (UPFC, a second generation FACTS controller, is well known for minimizing the cost of generation/losses with a good voltage profile as well as for ATC improvement. This paper conducts a detailed OPF study on a 9 bus system [7] for the above mentioned three objectives, with DGs and UPFC. To solve the OPF problem, Particle Swarm Optimization (PSO, a non conventional technique is used.

  15. Hybrid Power Forecasting Model for Photovoltaic Plants Based on Neural Network with Air Quality Index

    Directory of Open Access Journals (Sweden)

    Idris Khan

    2017-01-01

    Full Text Available High concentration of greenhouse gases in the atmosphere has increased dependency on photovoltaic (PV power, but its random nature poses a challenge for system operators to precisely predict and forecast PV power. The conventional forecasting methods were accurate for clean weather. But when the PV plants worked under heavy haze, the radiation is negatively impacted and thus reducing PV power; therefore, to deal with haze weather, Air Quality Index (AQI is introduced as a parameter to predict PV power. AQI, which is an indication of how polluted the air is, has been known to have a strong correlation with power generated by the PV panels. In this paper, a hybrid method based on the model of conventional back propagation (BP neural network for clear weather and BP AQI model for haze weather is used to forecast PV power with conventional parameters like temperature, wind speed, humidity, solar radiation, and an extra parameter of AQI as input. The results show that the proposed method has less error under haze condition as compared to conventional model of neural network.

  16. Ultracompact on-chip photothermal power monitor based on silicon hybrid plasmonic waveguides

    Science.gov (United States)

    Wu, Hao; Ma, Ke; Shi, Yaocheng; Wosinski, Lech; Dai, Daoxin

    2017-08-01

    We propose and demonstrate an ultracompact on-chip photothermal power monitor based on a silicon hybrid plasmonic waveguide (HPWG), which consists of a metal strip, a silicon core, and a silicon oxide (SiO2) insulator layer between them. When light injected to an HPWG is absorbed by the metal strip, the temperature increases and the resistance of the metal strip changes accordingly due to the photothermal and thermal resistance effects of the metal. Therefore, the optical power variation can be monitored by measuring the resistance of the metal strip on the HPWG. To obtain the electrical signal for the resistance measurement conveniently, a Wheatstone bridge circuit is monolithically integrated with the HPWG on the same chip. As the HPWG has nanoscale light confinement, the present power monitor is as short as 3 μm, which is the smallest photothermal power monitor reported until now. The compactness helps to improve the thermal efficiency and the response speed. For the present power monitor fabricated with simple fabrication processes, the measured responsivity is as high as about 17.7 mV/mW at a bias voltage of 2 V and the power dynamic range is as large as 35 dB.

  17. Ultracompact on-chip photothermal power monitor based on silicon hybrid plasmonic waveguides

    Directory of Open Access Journals (Sweden)

    Wu Hao

    2017-08-01

    Full Text Available We propose and demonstrate an ultracompact on-chip photothermal power monitor based on a silicon hybrid plasmonic waveguide (HPWG, which consists of a metal strip, a silicon core, and a silicon oxide (SiO2 insulator layer between them. When light injected to an HPWG is absorbed by the metal strip, the temperature increases and the resistance of the metal strip changes accordingly due to the photothermal and thermal resistance effects of the metal. Therefore, the optical power variation can be monitored by measuring the resistance of the metal strip on the HPWG. To obtain the electrical signal for the resistance measurement conveniently, a Wheatstone bridge circuit is monolithically integrated with the HPWG on the same chip. As the HPWG has nanoscale light confinement, the present power monitor is as short as ~3 μm, which is the smallest photothermal power monitor reported until now. The compactness helps to improve the thermal efficiency and the response speed. For the present power monitor fabricated with simple fabrication processes, the measured responsivity is as high as about 17.7 mV/mW at a bias voltage of 2 V and the power dynamic range is as large as 35 dB.

  18. Optimal Power Scheduling for a Grid-Connected Hybrid PV-Wind-Battery Microgrid System

    DEFF Research Database (Denmark)

    Hernández, Adriana Carolina Luna; Aldana, Nelson Leonardo Diaz; Savaghebi, Mehdi

    2016-01-01

    In this paper, a lineal mathematical model is proposed to schedule optimally the power references of the distributed energy resources in a grid-connected hybrid PVwind-battery microgrid. The optimization of the short term scheduling problem is addressed through a mixed-integer linear programming...... mathematical model, wherein the cost of energy purchased from the main grid is minimized and profits for selling energy generated by photovoltaic arrays are maximized by considering both physical constraints and requirements for a feasible deployment in the real system. The optimization model is tested...

  19. Operating manual for hybrid thermosyphons at the Gakona Power Plant, Alaska. Special report

    Energy Technology Data Exchange (ETDEWEB)

    Haynes, F.D.; Crory, F.C.; Knuth, K.V.; Quinn, W.F.

    1994-03-01

    A power plant building was constructed in 1990 at an over-the-horizon radar site in Gakona, Alaska. Since it was built on permafrost, thermal protection between the building and the underlying permafrost was included in the design, which included rigid board insulation and hybrid thermosyphons placed in the gravel fill under the building. Soil temperature is monitored with eight thermistor strings placed under and at the building perimeter. This manual describes the steps that must be taken to ensure foundation stability, including directions on when to use the thermosyphons in the active, mechanical refrigeration mode. A data acquisition system using a computer-controlled datalogger is described.

  20. Hybrid high-energy high-power pulsewidth-tunable picosecond source.

    Science.gov (United States)

    Pouysegur, Julien; Guichard, Florent; Zaouter, Yoann; Hanna, Marc; Druon, Frédéric; Hönninger, Clemens; Mottay, Eric; Georges, Patrick

    2015-11-15

    A hybrid ytterbium-doped fiber-bulk laser source allowing the generation of 3 ps, 350 μJ, 116 MW peak power Fourier transform-limited pulses at 50 kHz repetition rate and 1030 nm wavelength is described. Pulse duration tunability is provided by an adjustable spectral compression-based seeder system. Energy scaling capabilities of the architecture by use of the divided-pulse amplification method are investigated. This source provides a robust, compact, and versatile solution for applications such as RF photocathode guns, x- and γ-ray generation by inverse Compton scattering, and optical parametric chirped-pulse amplification pumping.

  1. Optimal Sizing and Operation of Stand-Alone Hybrid Power Systems

    DEFF Research Database (Denmark)

    Kyriakidis, Ioannis; Chaudhary, Sanjay; Pillai, Jayakrishnan Radhakrishna

    2014-01-01

    for autonomous applications. Based on the island’s wind and solar potential, wind and solar systems appear as the most competitive solution while battery technologies provide the most feasible option for storing the excess energy. In the next, simulation models are developed in HOMER software. Various ratings....... The main criterion for this evaluation is the improvement of steady-state voltage magnitude and minimization of power losses. The final part analyzes the hybrid system’s stability. An aggregated dynamic model is constructed based on built-in models from DIgSILENT library. The results highlight the battery’s...

  2. Design, control and power management of a battery/ultra-capacitor hybrid system for small electric vehicles

    DEFF Research Database (Denmark)

    Li, Zhihao; Onar, Omer; Khaligh, Alireza

    2009-01-01

    This paper introduces design, control, and power management of a battery/ultra-capacitor hybrid system, utilized for small electric vehicles (EV). The batteries are designed and controlled to work as the main energy storage source of the vehicle, supplying average power to the load; and the ultra-capacitors...

  3. Compact Hybrid Subsystem of 16 Channel Optical Demultiplexer, 2x2 Switches, Optical Power Monitors and Control Circuit

    Institute of Scientific and Technical Information of China (English)

    Kenichiro Takahashi; Toshihiko Kishimoto; Shintaro Mouri; Youichi Hata; Hideaki Yusa; Mitsuaki Tamura; Kazuhito Saito; Hisao Maki

    2003-01-01

    A compact hybrid subsystem of 16channel optical demultiplexer, 2x2 switches, optical power monitors and control circuit board is developed. The subsystem is able to add or drop arbitrary optical channels and monitor the optical power level by software commands. The size of the subsystem is 170x200x30(mm).

  4. Dynamic Stability Enhancement and Power Flow Control of a Hybrid Wind and Marine-Current Farm Using SMES

    DEFF Research Database (Denmark)

    Wang, Li; Chen, Shiang-Shong; Lee, Wei-Jen

    2009-01-01

    This paper presents a control scheme based on a superconducting magnetic energy storage (SMES) unit to achieve both power flow control and damping enhancement of a novel hybrid wind and marine-current farm (MCF) connected to a large power grid. The performance of the studied wind farm (WF) is sim...

  5. Design, control and power management of a battery/ultra-capacitor hybrid system for small electric vehicles

    DEFF Research Database (Denmark)

    Li, Zhihao; Onar, Omer; Khaligh, Alireza

    2009-01-01

    This paper introduces design, control, and power management of a battery/ultra-capacitor hybrid system, utilized for small electric vehicles (EV). The batteries are designed and controlled to work as the main energy storage source of the vehicle, supplying average power to the load; and the ultra...

  6. Techno-economical study of hybrid power system for a remote village in Algeria

    Energy Technology Data Exchange (ETDEWEB)

    Himri, Y. [Electricity and Gas National Enterprise (Sonelgaz), Bechar, 05 rue Mokadem Ahmed, Bechar (08000) (Algeria); Boudghene Stambouli, A. [Department of Electronics, University of Sciences and Technology of Oran (Algeria); Draoui, B. [Department of Mechanical Engineering, University of Bechar (Algeria); Himri, S. [Department of Fundamental Sciences, University of Bechar (Algeria)

    2008-07-15

    The share of renewable energy sources in Algeria primary energy supply is relatively low compared with European countries, though the trend of development is positive. One of the main strategic priorities of NEAL (New Energy Algeria), which is Algeria's renewable energy agency (government, Sonelgaz and Sonatrach), is striving to achieve a share of 10-12% renewable energy sources in primary energy supply by 2010.This article presents techno-economic assessment for off-grid hybrid generation systems of a site in south western Algeria. The HOMER model is used to evaluate the energy production, life-cycle costs and greenhouse gas emissions reduction for this study. In the present scenario, for wind speed less than 5.0 m/s the existing diesel power plant is the only feasible solution over the range of fuel prices used in the simulation. The wind diesel hybrid system becomes feasible at a wind speed of 5.48 m/s or more and a fuel price of 0.162$/L or more. If the carbon tax is taken into consideration and subsidy is abolished, then it is expected that the hybrid system will become feasible. The maximum annual capacity shortage did not have any effect on the cost of energy, which may be accounted for by larger sizes of wind machines and diesel generators. (author)

  7. A Novel Design and Optimization Software for Autonomous PV/Wind/Battery Hybrid Power Systems

    Directory of Open Access Journals (Sweden)

    Ali M. Eltamaly

    2014-01-01

    Full Text Available This paper introduces a design and optimization computer simulation program for autonomous hybrid PV/wind/battery energy system. The main function of the new proposed computer program is to determine the optimum size of each component of the hybrid energy system for the lowest price of kWh generated and the best loss of load probability at highest reliability. This computer program uses the hourly wind speed, hourly radiation, and hourly load power with several numbers of wind turbine (WT and PV module types. The proposed computer program changes the penetration ratio of wind/PV with certain increments and calculates the required size of all components and the optimum battery size to get the predefined lowest acceptable probability. This computer program has been designed in flexible fashion that is not available in market available software like HOMER and RETScreen. Actual data for Saudi sites have been used with this computer program. The data obtained have been compared with these market available software. The comparison shows the superiority of this computer program in the optimal design of the autonomous PV/wind/battery hybrid system. The proposed computer program performed the optimal design steps in very short time and with accurate results. Many valuable results can be extracted from this computer program that can help researchers and decision makers.

  8. Gravity Search Algorithm hybridized Recursive Least Square method for power system harmonic estimation

    Directory of Open Access Journals (Sweden)

    Santosh Kumar Singh

    2017-06-01

    Full Text Available This paper presents a new hybrid method based on Gravity Search Algorithm (GSA and Recursive Least Square (RLS, known as GSA-RLS, to solve the harmonic estimation problems in the case of time varying power signals in presence of different noises. GSA is based on the Newton’s law of gravity and mass interactions. In the proposed method, the searcher agents are a collection of masses that interact with each other using Newton’s laws of gravity and motion. The basic GSA algorithm strategy is combined with RLS algorithm sequentially in an adaptive way to update the unknown parameters (weights of the harmonic signal. Simulation and practical validation are made with the experimentation of the proposed algorithm with real time data obtained from a heavy paper industry. A comparative performance of the proposed algorithm is evaluated with other recently reported algorithms like, Differential Evolution (DE, Particle Swarm Optimization (PSO, Bacteria Foraging Optimization (BFO, Fuzzy-BFO (F-BFO hybridized with Least Square (LS and BFO hybridized with RLS algorithm, which reveals that the proposed GSA-RLS algorithm is the best in terms of accuracy, convergence and computational time.

  9. Mode Shift Control for a Hybrid Heavy-Duty Vehicle with Power-Split Transmission

    Directory of Open Access Journals (Sweden)

    Kun Huang

    2017-02-01

    Full Text Available Given that power-split transmission (PST is considered to be a major powertrain technology for hybrid heavy-duty vehicles (HDVs, the development and application of PST in the HDVs make mode shift control an essential aspect of powertrain system design. This paper presents a shift schedule design and torque control strategy for a hybrid HDV with PST during mode shift, intended to reduce the output torque variation and improve the shift quality (SQ. Firstly, detailed dynamic models of the hybrid HDV are developed to analyze the mode shift characteristics. Then, a gear shift schedule calculation method including a dynamic shift schedule and an economic shift schedule is provided. Based on the dynamic models and the designed shift schedule, a mode shift performance simulator is built using MATLAB/Simulink, and simulations are carried out. Through analysis of the dynamic equations, it is seen that the inertia torques of the motor–generator lead to the occurrence of transition torque. To avoid the unwanted transition torque, we use a mode shift control strategy that coordinates the motor–generator torque to compensate for the transition torque. The simulation and experimental results demonstrate that the output torque variation during mode shift is effectively reduced by the proposed control strategy, thereby improving the SQ.

  10. Optimal Sizing and Operation of Stand-Alone Hybrid Power Systems

    DEFF Research Database (Denmark)

    Kyriakidis, Ioannis; Chaudhary, Sanjay; Pillai, Jayakrishnan Radhakrishna

    2014-01-01

    The main goal of this study is to contribute to the design of an optimized hybrid renewable power plant for the island of Agios Efstratios. The initial step is to analyze the attributes and applications of various energy generation and storage technologies and focus on the most suitable ones...... of Renewable Energy Sources and Energy Storage Systems are considered and the most feasible combinations with respect to the Net Present Cost are calculated. The results have been assessed according to three scenarios, each of them representing a different policy and encountering several constraints....... Afterwards, steady-state analysis of the network is carried out considering typical cases of seasonal demand. The static model is developed in DIgSILENT PowerFactory software and the system’s behavior is investigated. In the following, the optimal placement for the wind, solar and storage units is discussed...

  11. Pattern of secure bilateral transactions ensuring power economic dispatch in hybrid electricity markets

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Ashwani; Gao, Wenzhong [Department of Electrical and Computer Engineering, Tennessee Tech University, Cookeville, TN 38505 (United States)

    2009-07-15

    This paper proposes a new method for secure bilateral transactions determination ensuring economic power dispatch of the generators using new AC distribution factors for pool and bilateral coordinated markets. The new optimization problem considers simultaneous minimization of deviations from scheduled transactions and fuel cost of the generators in the network. The fuel cost has been obtained for hybrid market model and impact of different percentage of bilateral demand on fuel cost, generation share, and pattern of transactions has also been determined. The impact of optimally located unified power flow controller (UPFC) on the bilateral transactions, fuel cost and generation pattern has also been studied. The results have also been obtained for pool market model. The proposed technique has been applied on IEEE 24-bus reliability test system (RTS). (author)

  12. Demand Side Management for Stand-Alone Hybrid Power Systems Based on Load Identification

    Directory of Open Access Journals (Sweden)

    Friederich Kupzog

    2012-11-01

    Full Text Available Within the field of Distributed Generation (DG, stand-alone Hybrid Power Systems (HPS are a suitable solution to provide energy to isolated facilities where the connection to a centralized grid is not affordable. The logical evolution of such systems involves the optimization of power resources and related control strategies, but also enhancements concerning the management of energy loads. This paper introduces Demand Side Management (DSM strategies specially designed for HPS. They are applied on a real and patented HPS that consists of PV panels, a diesel generator, an inverter and a set of batteries. DSM strategies are built up on a framework of distributed endpointdevices connected to a central control application where loads are identified according to their behavior. System network components, load definitions, the control application and DSM strategies are depicted. Finally, simulations show illustrative savings achieved by the application of some of the proposed strategies.

  13. Research and practice of designing hydro/photovoltaic hybrid power system in microgrid

    Institute of Scientific and Technical Information of China (English)

    Wang Yibo; Xu Honghua

    2013-01-01

    Small-hydro power station is often used in remote areas beside a river,but it doesn't match electricity demand so well,especially in dry seasons.A photovoltaic (PV) system with battery is a suitable option to complement the electricity gap.In this paper,a new structure of megawatt-class PV system integrating battery at DC-bus (DC:direct current) is proposed to be used in hydro/PV hybrid power system,and 4 main designing considerations and several key equipments are discussed.In 2011,a 2 MWp PV station with the proposed structure was built up in Yushu,China.From stability analysis,the station shows a strong stability under load cut-in/off and solar irradiance' s fluctuation.

  14. Prospects of Wind-Diesel Generator-Battery Hybrid Power System: A Feasibility Study in Algeria

    Directory of Open Access Journals (Sweden)

    Djohra Saheb-Koussa

    2013-01-01

    Full Text Available The present work analyses the feasibility of a wind-diesel generator-battery hybrid system. The wind energy resource data are collected from the weather station at the Renewable Energy Development Center of Bouzareah in Algeria. The recorded values vary from 5.5 m/s to 7 m/s at 25 m. The hybrid system analysis has shown that for a household consuming 1,270 kWh/yr, the cost of energy is 1.205 USD/kWh and produces 2,493 kWh/yr in which 93% of electricity comes from wind energy. From this study, it is clear that the optimized hybrid system is more cost effective compared to the diesel generator system alone where the NPC and COE are equal, respectively, to 19,561 USD and 1.205 USD/kWh and 47,932 USD and 2.952 USD/kWh. The sensitivity analysis predicts that the grid extension distance varies from 1.25 to 1.85 km depending on wind speed and fuel price which indicate a positive result to implement a stand-alone hybrid power system as an alternative to grid extension. In addition to the feasibility of this system, it can reduce the emission of the CO2, SO2, and NOx, respectively, from 4758 to 147, from 9.45 to 0.294, and from 105 to 3.23 kg/yr. Investments in autonomous renewable energy systems should be considered particularly in remote areas. They can be financed in the framework of the National Energy Action Plan of Algeria.

  15. High RF power test of a lower hybrid module mock-up in carbon fiber composite

    Energy Technology Data Exchange (ETDEWEB)

    Goniche, M.; Bibet, P.; Brossaud, J.; Cano, V.; Froissard, P.; Kazarian, F.; Rey, G. [Association Euratom-CEA Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee; Maebara, S.; Kiyono, K.; Seki, M.; Suganuma, K.; Ikeda, Y.; Imai, T. [Japan Atomic Energy Research Inst., Tokyo (Japan). Dept. of Fusion Facility

    1999-02-01

    A mock-up module of a Lower Hybrid Current Drive antenna module of a Carbon Fiber Composite (CFC) was fabricated for the development of heat resistive front facing the plasma. This module is made from CFC plates and rods which are copper coated to reduce the RF losses. The withstand-voltage, the RF properties and outgassing rates for long pulses and high RF power were tested at the Lower Hybrid test bed facility of Cadarache. After the short pulse conditioning, long pulses with a power density ranging between 50 and 150 MW/m{sup 2} were performed with no breakdowns. During these tests, the module temperaturewas increasing from 100-200 deg. C to 400-500 deg. C. It was also checked that high power density, up to 150 MW/m{sup 2}, could be transmitted when the waveguides are filled with H{sub 2} at a pressure of 5 x 10{sup -2} Pa. No significant change in the reflection coefficient is measured after the long pulse operation. During a long pulse, the power reflection increases during the pulse typically from 0.8% to 1.3%. It is concluded that the outgassing rate of Cu-plated CFC is about 6 times larger than of Dispersion Strengthened Copper (DSC) module at the module temperature of 300 deg. C. No significant increase of the global outgassing of the CFC module was measured after hydrogen pre-filling. After the test, visual inspection revealed that peeling of the copper coating occurred at one end of the module only on a very small area (0.2 cm{sup 2}). It is assessed that a CFC module is an attractive candidate for the hardening of the tip of the LHCD antenna. (authors)

  16. High RF power test of a CFC antenna module for lower hybrid current drive

    Energy Technology Data Exchange (ETDEWEB)

    Maebara, S.; Seki, M.; Ikeda, Y.; Kiyono, K.; Suganuma, K.; Imai, T. [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment; Goniche, M.; Bibet, Ph.; Brossaud, J.; Cano, V.; Kazarian-Vibert, F.; Froissard, P.; Rey, G. [Association Euratom-CEA Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee

    1998-07-01

    A mock-up of a 3.7 GHz Lower Hybrid Current Drive (LHCD) antenna module was fabricated from Carbon Fibre Composite (CFC) for the development of heat resistive low Z front facing the plasma. This 2 divided waveguide module is made from CFC plates and rods which are Cu-plated to reduce the RF losses. The withstand-voltage, the RF properties and the outgassing rates for long pulses and high RF power were tested at the Lower Hybrid test bed facility of Cadarache. A reference module made from Dispersion Strengthened Copper (DSC) was also fabricated. After the short pulse conditioning, long pulses with a power density ranging between 50 and 150 MW/m{sup 2} were performed with no breakdowns on the CFC module. It was also checked that the highest power density, up to 150 MW/m{sup 2}, could be transmitted when the waveguides are filled with H2 at a pressure of 5 x 10{sup -2} Pa. During a long pulse, the power reflection coefficient remains low in the 0.8-1.3 % range and no significant change in the reflection coefficient is measured after the thermal cycling provided by the long pulse operation. From thermocouple measurements, RF losses of the copper coated CFC and the DSC modules were compared. No significant differences were measured. From pressure measurements, it was found that the outgassing rate of Cu-plated CFC is about 6-7 times larger than of DSC at 300 deg.C. It is concluded that a CFC module is an attractive candidate for the hardening of the tip of the LHCD antenna. (author)

  17. Swarm Intelligence-Based Hybrid Models for Short-Term Power Load Prediction

    Directory of Open Access Journals (Sweden)

    Jianzhou Wang

    2014-01-01

    Full Text Available Swarm intelligence (SI is widely and successfully applied in the engineering field to solve practical optimization problems because various hybrid models, which are based on the SI algorithm and statistical models, are developed to further improve the predictive abilities. In this paper, hybrid intelligent forecasting models based on the cuckoo search (CS as well as the singular spectrum analysis (SSA, time series, and machine learning methods are proposed to conduct short-term power load prediction. The forecasting performance of the proposed models is augmented by a rolling multistep strategy over the prediction horizon. The test results are representative of the out-performance of the SSA and CS in tuning the seasonal autoregressive integrated moving average (SARIMA and support vector regression (SVR in improving load forecasting, which indicates that both the SSA-based data denoising and SI-based intelligent optimization strategy can effectively improve the model’s predictive performance. Additionally, the proposed CS-SSA-SARIMA and CS-SSA-SVR models provide very impressive forecasting results, demonstrating their strong robustness and universal forecasting capacities in terms of short-term power load prediction 24 hours in advance.

  18. Dynamic Analysis and Design Optimization of Series Hydraulic Hybrid System through Power Bond Graph Approach

    Directory of Open Access Journals (Sweden)

    R. Ramakrishnan

    2014-01-01

    Full Text Available The availability of natural gas and crude oil resources has been declining over the years. In automobile sector, the consumption of crude oil is 63% of total crude oil production in the world. Hence, automobile industries are placing more emphasis on energy efficient hydraulic hybrid systems, which can replace their conventional transmission systems. Series hydraulic hybrid system (SHHS is a multidomain mechatronics system with two distinct power sources that includes prime mover and hydropneumatic accumulator. It replaces the conventional transmission system to drive the vehicle. The sizing of the subsystems in SHHS plays a major role in improving the energy efficiency of the vehicle. In this paper, a power bond graph approach is used to model the dynamics of the SHHS. The obtained simulation results indicate the energy flow during various modes of operations. It also includes the dynamic response of hydropneumatic accumulator, prime mover, and system output speed. Further, design optimization of the system is carried out to optimize the process parameters for maximizing the system energy efficiency. This leads to increase in fuel economy and environmentally friendly vehicle.

  19. Scheduled power tracking control of the wind-storage hybrid system based on the reinforcement learning theory

    Science.gov (United States)

    Li, Ze

    2017-09-01

    In allusion to the intermittency and uncertainty of the wind electricity, energy storage and wind generator are combined into a hybrid system to improve the controllability of the output power. A scheduled power tracking control method is proposed based on the reinforcement learning theory and Q-learning algorithm. In this method, the state space of the environment is formed with two key factors, i.e. the state of charge of the energy storage and the difference value between the actual wind power and scheduled power, the feasible action is the output power of the energy storage, and the corresponding immediate rewarding function is designed to reflect the rationality of the control action. By interacting with the environment and learning from the immediate reward, the optimal control strategy is gradually formed. After that, it could be applied to the scheduled power tracking control of the hybrid system. Finally, the rationality and validity of the method are verified through simulation examples.

  20. Optimization of Electric Power Leveling Systems by a Novel Hybrid Algorithm with Simulated Evolution and Genetic Algorithms

    Science.gov (United States)

    Itoh, Jyunpei; Yamamoto, Masayoshi; Funabiki, Shigeyuki

    Electric power demand has an increasing tendency year by year. The fluctuation of the electric power causes further increase in the cost of the electric power facility and electricity charges. The development of the electric power-leveling systems (EPLS) using energy storage technology is desired to improve the electric power quality. The EPLS with a SMES is proposed as one of the countermeasures for the electric power quality improvement. However, the SMES is very expensive and it is difficult to decide the gains of the controller. It is essential in the practical use that the reduction of SMES capacity is realized. This paper proposes a new optimization method of the EPLS. The proposed algorithm is hybrid architecture with a combination of SimE (Simulated Evolution) and GA (Genetic Algorithms). The optimization of the EPLS can be achieved by the proposed hybrid algorithm compared to the SimE and the GA.

  1. A new topology of fuel cell hybrid power source for efficient operation and high reliability

    Science.gov (United States)

    Bizon, Nicu

    2011-03-01

    This paper analyzes a new fuel cell Hybrid Power Source (HPS) topology having the feature to mitigate the current ripple of the fuel cell inverter system. In the operation of the inverter system that is grid connected or supplies AC motors in vehicle application, the current ripple normally appears at the DC port of the fuel cell HPS. Consequently, if mitigation measures are not applied, this ripple is back propagated to the fuel cell stack. Other features of the proposed fuel cell HPS are the Maximum Power Point (MPP) tracking, high reliability in operation under sharp power pulses and improved energy efficiency in high power applications. This topology uses an inverter system directly powered from the appropriate fuel cell stack and a controlled buck current source as low power source used for ripple mitigation. The low frequency ripple mitigation is based on active control. The anti-ripple current is injected in HPS output node and this has the LF power spectrum almost the same with the inverter ripple. Consequently, the fuel cell current ripple is mitigated by the designed active control. The ripple mitigation performances are evaluated by indicators that are defined to measure the mitigation ratio of the low frequency harmonics. In this paper it is shown that good performances are obtained by using the hysteretic current control, but better if a dedicated nonlinear controller is used. Two ways to design the nonlinear control law are proposed. First is based on simulation trials that help to draw the characteristic of ripple mitigation ratio vs. fuel cell current ripple. The second is based on Fuzzy Logic Controller (FLC). The ripple factor is up to 1% in both cases.

  2. Very-short-term wind power prediction by a hybrid model with single- and multi-step approaches

    Science.gov (United States)

    Mohammed, E.; Wang, S.; Yu, J.

    2017-05-01

    Very-short-term wind power prediction (VSTWPP) has played an essential role for the operation of electric power systems. This paper aims at improving and applying a hybrid method of VSTWPP based on historical data. The hybrid method is combined by multiple linear regressions and least square (MLR&LS), which is intended for reducing prediction errors. The predicted values are obtained through two sub-processes:1) transform the time-series data of actual wind power into the power ratio, and then predict the power ratio;2) use the predicted power ratio to predict the wind power. Besides, the proposed method can include two prediction approaches: single-step prediction (SSP) and multi-step prediction (MSP). WPP is tested comparatively by auto-regressive moving average (ARMA) model from the predicted values and errors. The validity of the proposed hybrid method is confirmed in terms of error analysis by using probability density function (PDF), mean absolute percent error (MAPE) and means square error (MSE). Meanwhile, comparison of the correlation coefficients between the actual values and the predicted values for different prediction times and window has confirmed that MSP approach by using the hybrid model is the most accurate while comparing to SSP approach and ARMA. The MLR&LS is accurate and promising for solving problems in WPP.

  3. A Novel Evaluation Model for Hybrid Power System Based on Vague Set and Dempster-Shafer Evidence Theory

    Directory of Open Access Journals (Sweden)

    Dongxiao Niu

    2012-01-01

    Full Text Available Because clean energy and traditional energy have different advantages and disadvantages, it is of great significance to evaluate comprehensive benefits for hybrid power systems. Based on thorough analysis of important characters on hybrid power systems, an index system including security, economic benefit, environmental benefit, and social benefit is established in this paper. Due to advantages of processing abundant uncertain and fuzzy information, vague set is used to determine the decision matrix. Convert vague decision matrix to real one by vague combination ruleand determine uncertain degrees of different indexes by grey incidence analysis, then the mass functions of different comment set in different indexes are obtained. Information can be fused in accordance with Dempster-Shafer (D-S combination rule and the evaluation result is got by vague set and D-S evidence theory. A simulation of hybrid power system including thermal power, wind power, and photovoltaic power in China is provided to demonstrate the effectiveness and potential of the proposed design scheme. It can be clearly seen that the uncertainties in decision making can be dramatically decreased compared with existing methods in the literature. The actual implementation results illustrate that the proposed index system and evaluation model based on vague set and D-S evidence theory are effective and practical to evaluate comprehensive benefit of hybrid power system.

  4. A Modular Cascaded Multilevel Inverter Based Shunt Hybrid Active Power Filter for Selective Harmonic and Reactive Power Compensation Under Distorted/Unbalanced Grid Voltage Conditions

    Directory of Open Access Journals (Sweden)

    T. Demirdelen

    2016-10-01

    Full Text Available In recent years, shunt hybrid active power filters are being increasingly considered as a viable alternative to both passive filters and active power filters for compensating harmonics. In literature, their applications are restricted to balanced systems and low voltage applications and therefore not for industrial applications. This paper investigates the performance of a modular cascaded multilevel inverter based Shunt Hybrid Active Power Filter (SHAPF for reactive power compensation and selective harmonics elimination under distorted/unbalanced grid voltage conditions in medium voltage levels. In the proposed control method, reactive power compensation is achieved successfully with a perceptible amount and the performance results of harmonic compensation are satisfactory. Theoretical analysis and simulation results are obtained from an actual industrial network model in PSCAD. The simulation results are presented for a proposed system in order to demonstrate that the harmonic compensation performance meets the IEEE-519 standard.

  5. Cost Effectiveness Analysis of Quasi-Static Wireless Power Transfer for Plug-In Hybrid Electric Transit Buses: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Lijuan; Gonder, Jeff; Burton, Evan; Brooker, Aaron; Meintz, Andrew; Konan, Arnaud

    2015-11-11

    This study evaluates the costs and benefits associated with the use of a plug-in hybrid electric bus and determines the cost effectiveness relative to a conventional bus and a hybrid electric bus. A sensitivity sweep analysis was performed over a number of a different battery sizes, charging powers, and charging stations. The net present value was calculated for each vehicle design and provided the basis for the design evaluation. In all cases, given present day economic assumptions, the conventional bus achieved the lowest net present value while the optimal plug-in hybrid electric bus scenario reached lower lifetime costs than the hybrid electric bus. The study also performed parameter sensitivity analysis under low market potential assumptions and high market potential assumptions. The net present value of plug-in hybrid electric bus is close to that of conventional bus.

  6. Decentralized Method for Load Sharing and Power Management in a Hybrid Single/Three-Phase Islanded Microgrid Consisting of Hybrid Source PV/Battery Units

    DEFF Research Database (Denmark)

    Karimi, Yaser; Oraee, Hashem; Guerrero, Josep M.

    2017-01-01

    This paper proposes a new decentralized power management and load sharing method for a photovoltaic based, hybrid single/three-phase islanded microgrid consisting of various PV units, battery units and hybrid PV/battery units. The proposed method is not limited to the systems with separate PV...... and battery units, and power flow among different phases is performed automatically through three-phase units. The proposed method takes into account the available PV power and battery conditions of the units to share the load among them. To cover all possible conditions of the microgrid, the operation...... in different load, PV generation and battery conditions is validated experimentally in a microgrid lab prototype consisted of one three-phase unit and two single-phase units....

  7. Triboelectric-pyroelectric-piezoelectric hybrid cell for high-efficiency energy-harvesting and self-powered sensing.

    Science.gov (United States)

    Zi, Yunlong; Lin, Long; Wang, Jie; Wang, Sihong; Chen, Jun; Fan, Xing; Yang, Po-Kang; Yi, Fang; Wang, Zhong Lin

    2015-04-08

    A triboelectric-pyroelectric-piezoelectric hybrid cell, consisting of a triboelectric nanogenerator and a pyroelectric-piezoelectric nanogenerator, is developed for highly efficient mechanical energy harvesting through multiple mechanisms. The excellent performance of the hybrid cell enhances the energy-harvesting efficiency significantly (by 26.2% at 1 kΩ load resistance), and enables self-powered sensing, which will lead to a variety of advanced applications.

  8. Optimization of RF power absorption by optimization techniques using the lower hybrid current drive of FTU

    Energy Technology Data Exchange (ETDEWEB)

    Centioli, C. [Associazione Euratom/ENEA Sulla Fusione, Centro Ricerche Frascati, Via E. Fermi 45, CP 65, 00044 Frascati, Rome (Italy); Iannone, F. [Associazione Euratom/ENEA Sulla Fusione, Centro Ricerche Frascati, Via E. Fermi 45, CP 65, 00044 Frascati, Rome (Italy); Mazza, G. [Associazione Euratom/ENEA Sulla Fusione, Centro Ricerche Frascati, Via E. Fermi 45, CP 65, 00044 Frascati, Rome (Italy); Panella, M. [Associazione Euratom/ENEA Sulla Fusione, Centro Ricerche Frascati, Via E. Fermi 45, CP 65, 00044 Frascati, Rome (Italy); Pangione, L. [Dipartimento di Informatica, Sistemi e Produzione, Universita di Roma, Tor Vergata, Via del Politecnico 1, 00133 Rome (Italy)]. E-mail: pangione@frascati.enea.it; Podda, S. [Associazione Euratom/ENEA Sulla Fusione, Centro Ricerche Frascati, Via E. Fermi 45, CP 65, 00044 Frascati, Rome (Italy); Tuccillo, A. [Associazione Euratom/ENEA Sulla Fusione, Centro Ricerche Frascati, Via E. Fermi 45, CP 65, 00044 Frascati, Rome (Italy); Vitale, V. [Associazione Euratom/ENEA Sulla Fusione, Centro Ricerche Frascati, Via E. Fermi 45, CP 65, 00044 Frascati, Rome (Italy); Zaccarian, L. [Dipartimento di Informatica, Sistemi e Produzione, Universita di Roma, Tor Vergata, Via del Politecnico 1, 00133 Rome (Italy)

    2005-11-15

    In this paper, we will report on the experimental results arising from the implementation of optimization techniques to maximize the RF power coupling versus the plasma conditions in the FTU experimental facility. These experiments are carried out by employing the open-source Linux-RTAI control system currently running on the FTU digital feedback loop. The RF power source under consideration is a lower hybrid system (LH) based on six gyrotrons with a nominal power output capability of 1.1 MW each. The optimization of the coupling level between the plasma and the emitting antenna reduces the reflected power, thus maximizing the heating effects in addition to avoiding danger to the emitter (equivalently, annoying safety shutdowns of the system). To this aim, the plasma displacement is modified by suitably adjusting the reference input to the stabilizing feedback, according to a steepest descent algorithm. It will be shown in the paper how this algorithm achieves a satisfactory level of robustness with respect to measurement errors and well performs both in simulation and in experimental tests, thus leading to an improved effectiveness of the RF heating system.

  9. Design and Modeling of Grid Connected Hybrid Renewable Energy Power Generation

    Directory of Open Access Journals (Sweden)

    M. Kishore Reddy,

    2014-09-01

    Full Text Available This paper proposes a design and modeling of grid connected hybrid renewable energy power generation. The energy system having a photo voltaic (PV panel, Srg wind turbine and fuel cell (sofc for continuous power flow management. Fuel cells (storage & generating are added to ensure uninterrupted power supply due to the discontinuous nature of solar and wind resources. Renewable energy generated during times of plenty can be stored for use during periods when sufficient electricity is not available. But storing this energy is a difficult task: batteries and similar technologies perform well over short timescales, but over periods of weeks or months a different approach is necessary. Energy storage in the form of hydrogen is one such possibility: excess electricity is fed into an electrolyser to split water into its constituent parts, oxygen and hydrogen. The hydrogen is then used in fuel cells to produce electricity when needed which will overcome the problem of storage. This work is mainly concentrated on the design, analysis and modelling of Fuel cells and Analysis and modelling of Switched Reluctance Generator (SRG in the application of Wind Energy Generation and pv cell. Also an effective approach is proposed in this thesis to ensure renewable energy diversity and effective utilization. The pv cell, wind and fuel cell renewable energy system is digitally simulated using the MATLAB/SIMULINK software environment and fully validated for efficient energy utilizations and enhanced interface power quality under different operating conditions and load excursions

  10. Design of a hybrid wind power storage and generation system for a remote community

    Energy Technology Data Exchange (ETDEWEB)

    Devgan, S.S.; Walker, D.R. Jr. [Tennessee State Univ., Nashville, TN (United States)

    1995-12-31

    There are thousands of small communities in various parts of the world, even in developed countries, that are too far away to be economically connected to an electric supply system. Clean water is essential for health and well being and electric energy is essential for economic development of the community. This paper describes the design of a {open_quotes}hybrid{close_quotes} Wind/Diesel power generation and storage system. and the electric power distribution system for a small rural community of 50 persons and live stock. The most cost effective and reliable system designed to satisfy reasonable growth over the next twenty-five years consists of three 10 kW wind turbines, a 30 kWh storage battery and a 17.5 kW backup diesel generator. This paper also describe efforts to train a neural network to predict wind power over the next time interval and few more time intervals. This is very essential for significant penetration of wind power systems.

  11. Predictive-model-based dynamic coordination control strategy for power-split hybrid electric bus

    Science.gov (United States)

    Zeng, Xiaohua; Yang, Nannan; Wang, Junnian; Song, Dafeng; Zhang, Nong; Shang, Mingli; Liu, Jianxin

    2015-08-01

    Parameter-matching methods and optimal control strategies of the top-selling hybrid electric vehicle (HEV), namely, power-split HEV, are widely studied. In particular, extant research on control strategy focuses on the steady-state energy management strategy to obtain better fuel economy. However, given that multi-power sources are highly coupled in power-split HEVs and influence one another during mode shifting, conducting research on dynamic coordination control strategy (DCCS) to achieve riding comfort is also important. This paper proposes a predictive-model-based DCCS. First, the dynamic model of the objective power-split HEV is built and the mode shifting process is analyzed based on the developed model to determine the reason for the system shock generated. Engine torque estimation algorithm is then designed according to the principle of the nonlinear observer, and the prediction model of the degree of shock is established based on the theory of model predictive control. Finally, the DCCS with adaptation for a complex driving cycle is realized by combining the feedback control and the predictive model. The presented DCCS is validated on the co-simulation platform of AMESim and Simulink. Results show that the shock during mode shifting is well controlled, thereby improving riding comfort.

  12. Power Management Based Current Control Technique for Photovoltaic-Battery Assisted Wind-Hydro Hybrid System

    Science.gov (United States)

    Ram Prabhakar, J.; Ragavan, K.

    2013-07-01

    This article proposes new power management based current control strategy for integrated wind-solar-hydro system equipped with battery storage mechanism. In this control technique, an indirect estimation of load current is done, through energy balance model, DC-link voltage control and droop control. This system features simpler energy management strategy and necessitates few power electronic converters, thereby minimizing the cost of the system. The generation-demand (G-D) management diagram is formulated based on the stochastic weather conditions and demand, which would likely moderate the gap between both. The features of management strategy deploying energy balance model include (1) regulating DC-link voltage within specified tolerances, (2) isolated operation without relying on external electric power transmission network, (3) indirect current control of hydro turbine driven induction generator and (4) seamless transition between grid-connected and off-grid operation modes. Furthermore, structuring of the hybrid system with appropriate selection of control variables enables power sharing among each energy conversion systems and battery storage mechanism. By addressing these intricacies, it is viable to regulate the frequency and voltage of the remote network at load end. The performance of the proposed composite scheme is demonstrated through time-domain simulation in MATLAB/Simulink environment.

  13. Transient Simulation Of A Solar-Hybrid Tower Power Plant With Open Volumetric Receiver At The Location Barstow

    OpenAIRE

    2013-01-01

    In this work the transient simulations of four hybrid solar tower power plant concepts with open-volumetric receiver technology for a location in Barstow-Daggett, USA, are presented. The open-volumetric receiver uses ambient air as heat transfer fluid and the hybridization is realized with a gas turbine. The Rankine cycle is heated by solar-heated air and/or by the gas turbine’s flue gases. The plant can be operated in solar-only, hybrid parallel or combined cycle-only mode as well a...

  14. A Polar Fuzzy Control Scheme for Hybrid Power System Using Vehicle-To-Grid Technique

    Directory of Open Access Journals (Sweden)

    Mohammed Elsayed Lotfy

    2017-07-01

    Full Text Available A novel polar fuzzy (PF control approach for a hybrid power system is proposed in this research. The proposed control scheme remedies the issues of system frequency and the continuity of demand supply caused by renewable sources’ uncertainties. The hybrid power system consists of a wind turbine generator (WTG, solar photovoltaics (PV, a solar thermal power generator (STPG, a diesel engine generator (DEG, an aqua-electrolyzer (AE, an ultra-capacitor (UC, a fuel-cell (FC, and a flywheel (FW. Furthermore, due to the high cost of the battery energy storage system (BESS, a new idea of vehicle-to-grid (V2G control is applied to use the battery of the electric vehicle (EV as equivalent to large-scale energy storage units instead of small batteries to improve the frequency stability of the system. In addition, EV customers’ convenience is taken into account. A minimal-order observer is used to estimate the supply error. Then, the area control error (ACE signal is calculated in terms of the estimated supply error and the frequency deviation. ACE is considered in the frequency domain. Two PF approaches are utilized in the intended system. The mission of each controller is to mitigate one frequency component of ACE. The responsibility for ACE compensation is shared among all parts of the system according to their speed of response. The performance of the proposed control scheme is compared to the conventional fuzzy logic control (FLC. The effectiveness and robustness of the proposed control technique are verified by numerical simulations under various scenarios.

  15. Energy Management of a Hybrid-Power Gas Engine-Driven Heat Pump

    Directory of Open Access Journals (Sweden)

    Qingkun Meng

    2015-10-01

    Full Text Available The hybrid-power gas engine-driven heat pump (HPGHP combines hybrid power technology with a gas engine heat pump. The engine in the power system is capable of operating constantly with high thermal efficiency and low emissions during different operating modes. In this paper, the mathematical models of various components is established, including the engine thermal efficiency map and the motor efficiency map. The comprehensive charging/discharging efficiency model and energy management optimization strategy model which is proposed to maximize the efficiency of instantaneous HPGHP system are established. Then, different charging/discharging torque limits are obtained. Finally, a novel gas engine economical zone control strategy which combined with the SOC of battery in real time is put forward. The main operating parameters of HPGHP system under energy management are simulated by Matlab/Simulink and validated by experimental data, such as engine and motor operating torque, fuel consumption rate and comprehensive efficiency, etc. The results show that during 3600 s’ run-time, the SOC value of battery packs varies between 0.58 and 0.705, the fuel consumption rate reaches minimum values of approximately 291.3 g/(kW h when the compressor speed is nearly 1550 rpm in mode D, the engine thermal efficiency and comprehensive efficiency reach maximum values of approximately 0.2727 and 0.2648 when the compressor speed is 1575 rpm and 1475 rpm, respectively, in mode D. In general, the motor efficiency can be maintained above 0.85 in either mode.

  16. An Application of Spectral Kurtosis to Separate Hybrid Power Quality Events

    Directory of Open Access Journals (Sweden)

    Juan José González de la Rosa

    2015-09-01

    Full Text Available For the development of the future smart grid, the detection of power quality events is a key issue for the power system monitoring. Voltage sags, swells, harmonics (variations and interruptions, which produce large losses for commercial and industrial consumers, are the main events to be considered due to the sensitivity of equipment to these electrical anomalies. The steady-state events are even more frequently accompanied by transients, the discrimination and localization being far more exigent and requiring advanced signal separating tools to be incorporated in the measurement equipment. This paper shows the event detection performance of the spectral kurtosis as a signal separating tool in the frequency domain. The disturbances under test are hybrid signals resulting from the coupling between amplitude defects and non-desired higher frequencies. Being a fourth-order spectrum, the kurtosis is confirmed as a noise-resistant tool that enhances impulsiveness, therefore characterizing the electrical anomalies. In the beginning of the analysis, the voltage sag is established as a reference; then, the disturbances (oscillatory transients and harmonics are coupled at the starting and ending instants of the sag, resulting in complex hybrid events. The results show that the spectral kurtosis enhances the detection Energies 2015, 8 9778 of both types of events (steady state and transients, which are outlined in a bump shape in the fourth-order frequency pattern and centered in the main carrier frequency. Indeed, while the oscillatory transients are associated with softer and lower-amplitude peaks, the harmonics correspond to crisper and higher ones. As these mixed electrical faults are very common in the actual power grid, the article postulates the higher-order spectra to be implemented in prospective online measurement instruments.

  17. Investigation of lower hybrid physics through power modulation experiments on Alcator C-Moda)

    Science.gov (United States)

    Schmidt, A.; Bonoli, P. T.; Meneghini, O.; Parker, R. R.; Porkolab, M.; Shiraiwa, S.; Wallace, G.; Wright, J. C.; Harvey, R. W.; Wilson, J. R.

    2011-05-01

    Lower hybrid current drive (LHCD) is an attractive tool for off-axis current profile control in magnetically confined tokamak plasmas and burning plasmas (ITER), because of its high current drive efficiency. The LHCD system on Alcator C-Mod operates at 4.6 GHz, with ~ 1 MW of coupled power, and can produce a wide range of launched parallel refractive index (n||) spectra. A 32 chord, perpendicularly viewing hard x-ray camera has been used to measure the spatial and energy distribution of fast electrons generated by lower hybrid (LH) waves. Square-wave modulation of LH power on a time scale much faster than the current relaxation time does not significantly alter the poloidal magnetic field inside the plasma and thus allows for realistic modeling and consistent plasma conditions for different n|| spectra. Inverted hard x-ray profiles show clear changes in LH-driven fast electron location with differing n||. Boxcar binning of hard x-rays during LH power modulation allows for ~ 1 ms time resolution which is sufficient to resolve the build-up, steady-state, and slowing-down phases of fast electrons. Ray-tracing/Fokker-Planck modeling in combination with a synthetic hard x-ray diagnostic shows quantitative agreement with the x-ray data for high n|| cases. The time histories of hollow x-ray profiles have been used to measure off-axis fast electron transport in the outer half of the plasma, which is found to be small on a slowing down time scale.

  18. Optimal reactive power and voltage control in distribution networks with distributed generators by fuzzy adaptive hybrid particle swarm optimisation method

    DEFF Research Database (Denmark)

    Chen, Shuheng; Hu, Weihao; Su, Chi

    2015-01-01

    A new and efficient methodology for optimal reactive power and voltage control of distribution networks with distributed generators based on fuzzy adaptive hybrid PSO (FAHPSO) is proposed. The objective is to minimize comprehensive cost, consisting of power loss and operation cost of transformers...... and capacitors, and subject to constraints such as minimum and maximum reactive power limits of distributed generators, maximum deviation of bus voltages, maximum allowable daily switching operation number (MADSON). Particle swarm optimization (PSO) is used to solve the corresponding mixed integer non......-linear programming problem (MINLP) and the hybrid PSO method (HPSO), consisting of three PSO variants, is presented. In order to mitigate the local convergence problem, fuzzy adaptive inference is used to improve the searching process and the final fuzzy adaptive inference based hybrid PSO is proposed. The proposed...

  19. Development of energy management system based on a power sharing strategy for a fuel cell-battery-supercapacitor hybrid tramway

    Science.gov (United States)

    Li, Qi; Chen, Weirong; Liu, Zhixiang; Li, Ming; Ma, Lei

    2015-04-01

    A hybrid powertrain configuration based on a proton exchange membrane (PEMFC), a battery and a supercapacitor (SC) is designed without grid connection for the LF-LRV tramway. In order to avoid rapid changes of power demand and achieve high efficiency without degrading the mechanism performance, a power sharing strategy based on a combination of fuzzy logic control (FLC) and Haar wavelet transform (Haar-WT) is proposed for an energy management system of the hybrid tramway. The results demonstrate that the proposed energy management system is able to ensure the major positive portion of the low frequency components of power demand can be deals with the PEMFC. The battery can help provide a portion of the positive low frequency components of power demand to reduce the PEMFC burden while the SC bank can supply all the high frequency components which could damage the PEMFC membrane. Therefore, the energy management system of high-power hybrid tramway is able to guarantee a safe operating condition with transient free for the PEMFC and extend the lifetime of each power source. Finally, the comparisons with other control strategies verify that the proposed energy management system can achieve better energy efficiency of the overall hybrid tramway.

  20. A Causal and Real-Time Capable Power Management Algorithm for Off-Highway Hybrid Propulsion Systems

    Directory of Open Access Journals (Sweden)

    Johannes Schalk

    2016-12-01

    Full Text Available Hybrid propulsion systems allow for a reduction of fuel consumption and pollutant emissions of future off-highway applications. A challenging aspect of a hybridization is the larger number of system components that further increases both the complexity and the diversification of such systems. Hence, beside a standardization on the hardware side for off-highway systems, a high flexibility and modularity of the control schemes is required to employ them in as many different applications as possible. In this paper, a causal optimization-based power management algorithm is introduced to control the power split between engine and electric machine in a hybrid powertrain. The algorithm optimizes the power split to achieve the maximum power supply efficiency and, thereby, considers the energy cost for maintaining the battery charge. Furthermore, the power management provides an optional function to control the battery state of charge in such a way that a target value is attained. In a simulation case study, the potential and the benefits of the proposed power management for the hybrid powertrain—aiming at a reduction of the fuel consumption of a DMU (diesel multiple unit train operated on a representative track—will be shown.

  1. A self-sustaining high-strength wastewater treatment system using solar-bio-hybrid power generation.

    Science.gov (United States)

    Bustamante, Mauricio; Liao, Wei

    2017-06-01

    This study focuses on system analysis of a self-sustaining high-strength wastewater treatment concept combining solar technologies, anaerobic digestion, and aerobic treatment to reclaim water. A solar bio-hybrid power generation unit was adopted to power the wastewater treatment. Concentrated solar power (CSP) and photovoltaics (PV) were combined with biogas energy from anaerobic digestion. Biogas is also used to store the extra energy generated by the hybrid power unit and ensure stable and continuous wastewater treatment. It was determined from the energy balance analysis that the PV-bio hybrid power unit is the preferred energy unit to realize the self-sustaining high-strength wastewater treatment. With short-term solar energy storage, the PV-bio-hybrid power unit in Phoenix, AZ requires solar collection area (4032m(2)) and biogas storage (35m(3)), while the same unit in Lansing, MI needs bigger solar collection area and biogas storage (5821m(2) and 105m(3), respectively) due to the cold climate. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. A Power Smoothing Control Strategy and Optimized Allocation of Battery Capacity Based on Hybrid Storage Energy Technology

    Directory of Open Access Journals (Sweden)

    Yong Li

    2012-05-01

    Full Text Available Wind power parallel operation is an effective way to realize the large scale use of wind power, but the fluctuations of power output from wind power units may have great influence on power quality, hence a new method of power smoothing and capacity optimized allocation based on hybrid energy storage technology is proposed in terms of the uncontrollable and unexpected characteristics of wind speed in wind farms. First, power smoothing based on a traditional Inertial Filter is introduced and the relationship between the time constant, its smoothing effect and capacity allocation are analyzed and combined with Proportional Integral Differential (PID control to realize power smoothing control of wind power. Then wavelet theory is adopted to realize a multi-layer decomposition of power output in some wind farms, a power smoothing model based on hybrid energy storage technology is constructed combining the characteristics of the Super Capacitor (SC and Battery Energy Storage System (BESS technologies. The hybrid energy storage system is available for power fluctuations with high frequency-low energy and low frequency-high energy to achieve good smoothing effects compared with a single energy storage system. The power fluctuations filtered by the Wavelet Transform is regarded as the target value of BESS, the charging and discharging control for battery is completed quickly by Model Algorithm Control (MAC. Because of the influence of the inertia and the response speed of the battery, its actual output is not completely equal to the target value which mainly reflects in high-frequency part, the difference part uses SC to compensate and makes the output of battery and SC closer to the target value on the whole. Compared with the traditional Inertial Filter and PID control method, the validity of the model was verified by simulation results. Finally under the premise of power grid standards, the corresponding capacity design had been given to reduce the

  3. Hybrid Automaton Based Controller Design for Damage Mitigation of Islanded Power Systems

    Science.gov (United States)

    Lahiri, Sudipta

    Spurred by increasingly unpredictable weather, high penetration of renewable resources and a period of focused US government policy, it is widely expected that microgrids within the electric distribution system will show exponential growth in the coming decade. Microgrids comprise of power generation, delivery and consumption assets within restricted electrical boundaries and under contiguous control oversight that enables holistic management of these assets. Microgrids can be islanded and operated independent of a larger electric power network, and as such, a primary function of microgrids is to enhance the energy reliability of the underlying loads. In this work, we focus on naval shipboard power systems. Apart from being islanded, in the true sense, resiliency and damage mitigation are key considerations in the design and operation of these power systems. Islanded power systems encompass a rich diversity of discrete and continuous dynamic behavior in multiple time-scales. A high penetration of devices with power electronics interface, low inherent system inertia, and high density of switching devices can lead to rapid disturbance propagation and system failure without advanced damage mitigation strategies. Hybrid systems formalism incorporates continuous dynamics as well as discrete switching behavior into a modeling and control framework, thus allowing a complete system description while crystallizing concepts of safety into system design criteria. We build on existing work to enhance a Dynamic Mixed Integer Programming (DMIP) model of a power system that combines continuous time differential algebraic models with switching dynamics synthesized into mixed integer inequalities. We use this model to derive an optimal system reconfiguration strategy to prevent voltage collapse of a benchmark shipboard power system. However, this methodology is restricted by the computational complexity of dynamic programming and scalability of non-automated processes. To overcome

  4. Simultaneously Harvesting Thermal and Mechanical Energies based on Flexible Hybrid Nanogenerator for Self-Powered Cathodic Protection.

    Science.gov (United States)

    Zhang, Hulin; Zhang, Shangjie; Yao, Guang; Huang, Zhenlong; Xie, Yuhang; Su, Yuanjie; Yang, Weiqing; Zheng, Chunhua; Lin, Yuan

    2015-12-30

    Metal corrosion occurs anytime and anywhere in nature and the corrosion prevention has a great significance everywhere in national economic development and daily life. Here, we demonstrate a flexible hybrid nanogenerator (NG) that is capable of simultaneously or individually harvesting ambient thermal and mechanical energies and used for a self-powered cathodic protection (CP) system without using an external power source. Because of its double peculiarities of both pyroelectric and piezoelectric properties, a polarized poly(vinylidene fluoride) (PVDF) film-based NG was constructed to scavenge both thermal and mechanical energies. As a supplementary, a triboelectric NG was constructed below the pyro/piezoelectric NG to grab ambient mechanical energy. The output power of the fabricated hybrid NG can be directly used to protect the metal surface from the chemical corrosion. Our results not only verify the feasibility of self-powered CP-based NGs, but also expand potential self-powered applications.

  5. Proposal and Development of a High Voltage Variable Frequency Alternating Current Power System for Hybrid Electric Aircraft

    Science.gov (United States)

    Sadey, David J.; Taylor, Linda M.; Beach, Raymond F.

    2017-01-01

    The development of ultra-efficient commercial vehicles and the transition to low-carbon emission propulsion are seen as strategic thrust paths within NASA Aeronautics. A critical enabler to these paths comes in the form of hybrid electric propulsion systems. For megawatt-class systems, the best power system topology for these hybrid electric propulsion systems is debatable. Current proposals within NASA and the Aero community suggest using a combination of alternating current (AC) and direct current (DC) for power generation, transmission, and distribution. This paper proposes an alternative to the current thought model through the use of a primarily high voltage AC power system, supported by the Convergent Aeronautics Solutions (CAS) Project. This system relies heavily on the use of doubly-fed induction machines (DFIMs), which provide high power densities, minimal power conversion, and variable speed operation. The paper presents background on the activity along with the system architecture, development status, and preliminary results.

  6. Application of Hybrid HS and Tabu Search Algorithm for Optimal Location of FACTS Devices to Reduce Power Losses in Power Systems

    Directory of Open Access Journals (Sweden)

    Z. Masomi Zohrabad

    2016-12-01

    Full Text Available Power networks continue to grow following the annual growth of energy demand. As constructing new energy generation facilities bears a high cost, minimizing power grid losses becomes essential to permit low cost energy transmission in larger distances and additional areas. This study aims to model an optimization problem for an IEEE 30-bus power grid using a Tabu search algorithm based on an improved hybrid Harmony Search (HS method to reduce overall grid losses. The proposed algorithm is applied to find the best location for the installation of a Unified Power Flow Controller (UPFC. The results obtained from installation of the UPFC in the grid are presented by displaying outputs.

  7. Numerical simulation of a hybrid CSP/Biomass 5 MWel power plant

    Science.gov (United States)

    Soares, João; Oliveira, Armando

    2017-06-01

    The fundamental benefit of using renewable energy systems is undeniable since they rely on a source that will not run out. Nevertheless, they strongly depend on meteorological conditions (solar, wind, etc.), leading to uncertainty of instantaneous energy supply and consequently to grid connection issues. An interesting concept is renewable hybridisation. This consists in the strategic combination of different renewable sources in the power generation portfolio by taking advantage of each technology. Hybridisation of concentrating solar power with biomass denotes a powerful way of assuring system stability and reliability. The main advantage is dispatchability through the whole extent of the operating range. Regarding concentrating solar power heat transfer fluid, direct steam generation is one of the most interesting concepts. Nevertheless, it presents itself technical challenges that are mostly related to the two-phase fluid flow in horizontal pipes, as well as the design of an energy storage system. Also, the use of reheat within the turbine is usually indirectly addressed, hindering system efficiency. These challenges can be addressed through hybridisation with biomass. In this paper, a hybrid renewable electricity generation system is presented. The system relies on a combination of solar and biomass sources to drive a 5 MWel steam turbine. System performance is analysed through numerical simulation using Ebsilon professional software. The use of direct reheat in the turbine is addressed. Results show that hybridisation results in an enhancement of system dispatchability and generation stability. Furthermore, hybridisation enhanced the annual solar field and power block efficiencies, and thus the system annual efficiency (from 7.6% to 20%). The use of direct reheat eliminates steam wetness in the last turbine stage and also improves system efficiency.

  8. Energy management of fuel cell/solar cell/supercapacitor hybrid power source

    Energy Technology Data Exchange (ETDEWEB)

    Thounthong, Phatiphat; Sethakul, Panarit [Department of Teacher Training in Electrical Engineering, King Mongkut' s University of Technology North Bangkok, 1518, Piboolsongkram Road, Bangsue, Bangkok 10800 (Thailand); Chunkag, Viboon [Department of Electrical Engineering, King Mongkut' s University of Technology North Bangkok, 1518, Piboolsongkram Road, Bangsue, Bangkok 10800 (Thailand); Sikkabut, Suwat [Thai-French Innovation Institute, King Mongkut' s University of Technology North Bangkok, 1518, Piboolsongkram Road, Bangsue, Bangkok 10800 (Thailand); Pierfederici, Serge; Davat, Bernard [Groupe de Recherche en Electrotechnique et Electronique de Nancy (GREEN: UMR 7037), Nancy Universite, INPL-ENSEM, 2, Avenue de la Foret de Haye, Vandoeuvre-les-Nancy, Lorraine 54516 (France)

    2011-01-01

    This study presents an original control algorithm for a hybrid energy system with a renewable energy source, namely, a polymer electrolyte membrane fuel cell (PEMFC) and a photovoltaic (PV) array. A single storage device, i.e., a supercapacitor (ultracapacitor) module, is in the proposed structure. The main weak point of fuel cells (FCs) is slow dynamics because the power slope is limited to prevent fuel starvation problems, improve performance and increase lifetime. The very fast power response and high specific power of a supercapacitor complements the slower power output of the main source to produce the compatibility and performance characteristics needed in a load. The energy in the system is balanced by d.c.-bus energy regulation (or indirect voltage regulation). A supercapacitor module functions by supplying energy to regulate the d.c.-bus energy. The fuel cell, as a slow dynamic source in this system, supplies energy to the supercapacitor module in order to keep it charged. The photovoltaic array assists the fuel cell during daytime. To verify the proposed principle, a hardware system is realized with analog circuits for the fuel cell, solar cell and supercapacitor current control loops, and with numerical calculation (dSPACE) for the energy control loops. Experimental results with small-scale devices, namely, a PEMFC (1200 W, 46 A) manufactured by the Ballard Power System Company, a photovoltaic array (800 W, 31 A) manufactured by the Ekarat Solar Company and a supercapacitor module (100 F, 32 V) manufactured by the Maxwell Technologies Company, illustrate the excellent energy-management scheme during load cycles. (author)

  9. Feasibility of a Hydraulic Power Assist System for Use in Hybrid Neuroprostheses

    Directory of Open Access Journals (Sweden)

    Kevin M. Foglyano

    2015-01-01

    Full Text Available Feasibility of using pressurized hydraulic fluid as a source of on-demand assistive power for hybrid neuroprosthesis combining exoskeleton with functional neuromuscular stimulation was explored. Hydraulic systems were selected as an alternative to electric motors for their high torque/mass ratio and ability to be located proximally on the exoskeleton and distribute power distally to assist in moving the joints. The power assist system (PAS was designed and constructed using off-the-shelf components to test the feasibility of using high pressure fluid from an accumulator to provide assistive torque to an exoskeletal hip joint. The PAS was able to provide 21 Nm of assistive torque at an input pressure of 3171 kPa with a response time of 93 ms resulting in 32° of hip flexion in an able-bodied test. The torque output was independent of initial position of the joint and was linearly related to pressure. Thus, accumulator pressure can be specified to provide assistive torque as needed in exoskeletal devices for walking or stair climbing beyond those possible either volitionally or with electrical stimulation alone.

  10. Harmonic estimation in a power system using a novel hybrid Least Squares-Adaline algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Joorabian, M.; Mortazavi, S.S.; Khayyami, A.A. [Electrical Engineering Department, Shahid Chamran University, Ahwaz, 61355 (Iran)

    2009-01-15

    Nowadays many algorithms have been proposed for harmonic estimation in a power system. Most of them deal with this estimation as a totally nonlinear problem. Consequently, these methods either converge slowly, like GA algorithm [U. Qidwai, M. Bettayeb, GA based nonlinear harmonic estimation, IEEE Trans. Power Delivery (December) 1998], or need accurate parameter adjustment to track dynamic and abrupt changes of harmonics amplitudes, like adaptive Kalman filter (KF) [Steven Liu, An adaptive Kalman filter for dynamic estimation of harmonic signals, in: 8th International Conference On Harmonics and Quality of Power, ICHQP'98, Athens, Greece, October 14-16, 1998]. In this paper a novel hybrid approach, based on the decomposition of the problem into a linear and a nonlinear problem, is proposed. A linear estimator, i.e., Least Squares (LS), which is simple, fast and does not need any parameter tuning to follow harmonics amplitude changes, is used for amplitude estimation and an adaptive linear combiner called 'Adaline', which is very fast and very simple is used to estimate phases of harmonics. An improvement in convergence and processing time is achieved using this algorithm. Moreover, better performance in online tracking of dynamic and abrupt changes of signals is the result of applying this method. (author)

  11. An Experimental Study of Laboratory Hybrid Power System with the Hydrogen Technologies

    Directory of Open Access Journals (Sweden)

    Daniel Minarik

    2014-01-01

    Full Text Available This paper presents very small laboratory hybrid photovoltaic-hydrogen power system. The system was primarily assembled to verify the operability of the control algorithms and practical deployment of available commercial hydrogen technologies that are directly usable for storage of electricity produced from renewable energy sources in a small island system. This energetic system was installed and tested in Laboratory of fuel cells that is located in the university campus of VSB-Technical University of Ostrava. The energetic system consists of several basic components: a photovoltaic field, accumulators bank, water commercial electrolyzer and compact fuel cell system. The weather conditions recorded in two different weeks as model weather and solar conditions are used as case studies to test the energetic system and the results for two different cases are compared each other. The results show and illustrate selected behaviour curves of the power system and also average energy storage efficiency for accumulation subsystem based on hydrogen technologies or at the energetic system embedded components. On the basis of real measurement and its evaluation the ideal parameters of the photovoltaic field were calculated as well as the hydrogen technologies for supposed purpose and the power requirements.

  12. Uncertainty analysis and design optimization of hybrid rocket motor powered vehicle for suborbital flight

    Directory of Open Access Journals (Sweden)

    Zhu Hao

    2015-06-01

    Full Text Available In this paper, we propose an uncertainty analysis and design optimization method and its applications on a hybrid rocket motor (HRM powered vehicle. The multidisciplinary design model of the rocket system is established and the design uncertainties are quantified. The sensitivity analysis of the uncertainties shows that the uncertainty generated from the error of fuel regression rate model has the most significant effect on the system performances. Then the differences between deterministic design optimization (DDO and uncertainty-based design optimization (UDO are discussed. Two newly formed uncertainty analysis methods, including the Kriging-based Monte Carlo simulation (KMCS and Kriging-based Taylor series approximation (KTSA, are carried out using a global approximation Kriging modeling method. Based on the system design model and the results of design uncertainty analysis, the design optimization of an HRM powered vehicle for suborbital flight is implemented using three design optimization methods: DDO, KMCS and KTSA. The comparisons indicate that the two UDO methods can enhance the design reliability and robustness. The researches and methods proposed in this paper can provide a better way for the general design of HRM powered vehicles.

  13. Study on Power Switching Process of a Hybrid Electric Vehicle with In-Wheel Motors

    Directory of Open Access Journals (Sweden)

    Shaohua Wang

    2016-01-01

    Full Text Available Hybrid electric vehicles with in-wheel motors (IWM achieve a variety of driving modes by two power sources—the engine and the IWM. One of the critical problems that exists in such vehicle is the different transient characteristics between the engine and the IWM. Therefore, switching processes between the power sources have noteworthy impacts on vehicle dynamics and driving performance. For the particular switching process of the pure electric mode to the engine driving mode, a specific control strategy coordinating clutch torque, motor torque, and engine torque was proposed to solve drivability issues caused by inconsistent responses of different power sources during the mode transition. The specific switching process could be described as follows: the engine was started by IWM with the clutch serving as a key enabling actuator, dynamic torque compensation through IWM was implemented after engine started, and, meanwhile, engine speed was controlled to track the target speed through the closed loop PID control strategy. The bench tests results showed that the vehicle jerk caused during mode switching was reduced and fast and smooth mode switching was realized, which leads to the improvement of vehicle’s riding comfort.

  14. Hybrid energy storage system for wireless sensor node powered by aircraft specific thermoelectric energy harvesting

    Science.gov (United States)

    Thangaraj, K.; Elefsiniotis, A.; Aslam, S.; Becker, Th.; Schmid, U.; Lees, J.; Featherston, C. A.; Pullin, R.

    2013-05-01

    This paper describes an approach for efficiently storing the energy harvested from a thermoelectric module for powering autonomous wireless sensor nodes for aeronautical health monitoring applications. A representative temperature difference was created across a thermo electric generator (TEG) by attaching a thermal mass and a cavity containing a phase change material to one side, and a heat source (to represent the aircraft fuselage) to the other. Batteries and supercapacitors are popular choices of storage device, but neither represents the ideal solution; supercapacitors have a lower energy density than batteries and batteries have lower power density than supercapacitors. When using only a battery for storage, the runtime of a typical sensor node is typically reduced by internal impedance, high resistance and other internal losses. Supercapacitors may overcome some of these problems, but generally do not provide sufficient long-term energy to allow advanced health monitoring applications to operate over extended periods. A hybrid energy storage unit can provide both energy and power density to the wireless sensor node simultaneously. Techniques such as acoustic-ultrasonic, acoustic-emission, strain, crack wire sensor and window wireless shading require storage approaches that can provide immediate energy on demand, usually in short, high intensity bursts, and that can be sustained over long periods of time. This application requirement is considered as a significant constraint when working with battery-only and supercapacitor-only solutions and they should be able to store up-to 40-50J of energy.

  15. A conceptual design of catalytic gasification fuel cell hybrid power plant with oxygen transfer membrane

    Science.gov (United States)

    Shi, Wangying; Han, Minfang

    2017-09-01

    A hybrid power generation system integrating catalytic gasification, solid oxide fuel cell (SOFC), oxygen transfer membrane (OTM) and gas turbine (GT) is established and system energy analysis is performed. In this work, the catalytic gasifier uses steam, recycled anode off-gas and pure oxygen from OTM system to gasify coal, and heated by hot cathode off-gas at the same time. A zero-dimension SOFC model is applied and verified by fitting experimental data. Thermodynamic analysis is performed to investigate the integrated system performance, and system sensitivities on anode off-gas back flow ratio, SOFC fuel utilization, temperature and pressure are discussed. Main conclusions are as follows: (1) System overall electricity efficiency reaches 60.7%(HHV) while the gasifier operates at 700 °C and SOFC at 850 °C with system pressure at 3.04 bar; (2) oxygen enriched combustion simplify the carbon-dioxide capture process, which derives CO2 of 99.2% purity, but results in a penalty of 6.7% on system electricity efficiency; (3) with SOFC fuel utilization or temperature increasing, the power output of SOFC increases while GT power output decreases, and increasing system pressure can improve both the performance of SOFC and GT.

  16. Evaluation of the Plug-in Hybrid Electric Vehicle Considering Power Generation Best Mix

    Science.gov (United States)

    Shinoda, Yukio; Tanaka, Hideo; Akisawa, Atsushi; Kashiwagi, Takao

    In transport section, it is necessary to reduce amount of CO2 emissions and Oil dependence. Bio fuels and Fuel Cell Vehicle (FCV), Electric Vehicle (EV) and Plug-in Hybrid Electric Vehicle (PHEV) are expected to reduce CO2 emissions and Oil dependence. We focus on PHEV. PHEV can reduce total energy Consumptions because of its high efficiency and can run with both oil and electricity. Introduction of PHEV reduces oil consumptions, however it also increases electricity demands. Therefore we must evaluate PHEV's CO2 reduction potential, not only in transport section but also in power grid section. To take into account of the distribution of the daily travel distance is also very important. All energy charged in the PHEV's battery cannot always be used. That influences the evaluation. We formulate the total model that combines passenger car model and power utility grid model, and we also consider the distribution of the daily travel distance. With this model, we show the battery cost per kWh at which PHEV begins to be introduced and oil dependence in passenger car section is to be reduced to 80%. We also show PHEV's CO2 reduction potentials and effects on the power supply system.

  17. Power sources for portable electronics and hybrid cars: lithium batteries and fuel cells.

    Science.gov (United States)

    Scrosati, Bruno

    2005-01-01

    The activities in progress in our laboratory for the development of batteries and fuel cells for portable electronics and hybrid car applications are reviewed and discussed. In the case of lithium batteries, the research has been mainly focused on the characterization of new electrode and electrolyte materials. Results related to disordered carbon anodes and improved, solvent-free, as well as gel-type, polymer electrolytes are particularly stressed. It is shown that the use of proper gel electrolytes, in combination with suitable electrode couples, allows the development of new types of safe, reliable, and low-cost lithium ion batteries which appear to be very promising power sources for hybrid vehicles. Some of the technologies proven to be successful in the lithium battery area are readapted for use in fuel cells. In particular, this approach has been followed for the preparation of low-cost and stable protonic membranes to be proposed as an alternative to the expensive, perfluorosulfonic membranes presently used in polymer electrolyte membrane fuel cells (PEMFCs). Copyright 2005 The Japan Chemical Journal Forum and Wiley Periodicals, Inc

  18. Aspect of Dynamic Simulation and Experimental Research Studies on Hybrid Pneumatic Power System

    Directory of Open Access Journals (Sweden)

    K. David Huang

    2010-01-01

    Full Text Available A Hybrid Pneumatic Power System (HPPS has been developed for several years with the major aim of reducing the vehicle fuel consumption, environment pollution and enhancing the vehicle performance as well. Comparing with the conventional hybrid system, HPPS replaces the battery's electrochemical energy with a high-pressure air storage tank and enables the internal combustion engine (ICE to function at its sweet spot. Besides, the HPPS, which effectively merges both the high-pressure air flow from the storage tank and the recycled exhaust flow from the ICE, thereby increases the thermal efficiency of the ICE and transforms the merged flow energy into mechanical energy using a high-efficiency turbine. This paper focuses on the major research process into HPPSs, including overall dynamic simulation and experimental validation. By using the simulation tool ITI-Sim, this research demonstrates an experiment which can be operated precisely according to the requirements of various driving conditions under which a car actually runs on the road in accordance with the regulated running vehicle test mode. HPPS is expected to increase the performance of the entire system from 15% to 39%, and is likely to replace the traditional system in the coming years.

  19. PRICING ELECTRIC POWER UNDER A HYBRID WHOLESALE MECHANISM: EVALUATING THE TURKISH ELECTRICITY MARKET

    Directory of Open Access Journals (Sweden)

    Hatice Karahan

    2013-01-01

    Full Text Available During the restructuring process, Turkish electricity sector has gone through significant changes both in wholesale and retail markets. In this framework, the Market Financial Settlement Mechanism established for handling market imbalances has become a spot market in time. So, it can be claimed that the wholesale electricity market in Turkey is a hybrid mechanism composed of bilateral contracts and the balancing market. On the other hand, the main target of liberalization program is providing consumers with affordable electric power. Hence, this study attempts to explore the link between retail tariffs for ineligible consumers and prices in the two wholesale mechanisms, in the period after the launch of the day-ahead market. Findings suggest that regulated wholesale prices are more effective in the determination of end-user prices, whereas unregulated ones might have a price reduction effect in case the free market dominates. However, the volatility in spot market prices implies that the sector would better continue with the hybrid mechanism for quite some time.

  20. Optimal Hybrid Renewable Airport Power System: Empirical Study on Incheon International Airport, South Korea

    Directory of Open Access Journals (Sweden)

    Seoin Baek

    2016-06-01

    Full Text Available In response to global energy problems (e.g., the oil crisis, the Fukushima accident, the Paris Agreement, the South Korean government has executed a strict renewable energy plan to decrease the country’s dependence on fossil fuel. Public facilities, such as international airports, which use substantial amounts of electricity, are the most in need of government regulation. In this study, we attempt to determine the optimal hybrid electricity generation system for South Korea’s largest airport: Incheon International Airport. In the analysis, we use three scenarios: the current load, 120% of the current load, and 140% of the current load, according to the plan to expand Incheon International Airport. According to the COE (cost of electricity and the NPC (net present cost of the result, it is economically feasible to completely cover the potential increase in the electric load with PV power. Government policy implications and limitations are discussed.

  1. A low power wide-band CMOS PLL frequency synthesizer for portable hybrid GNSS receiver

    Energy Technology Data Exchange (ETDEWEB)

    Xiao Shimao; Yu Yunfeng; Ma Chengyan; Ye Tianchun [Institute of Microelectronics, Chinese Academy of Sciences, Beijing 100029 (China); Yin Ming, E-mail: xiaoshimao@casic.ac.c [Hangzhou Zhongke Microelectronics Co Ltd, Hangzhou 310053 (China)

    2010-03-15

    The design consideration and implementation of a CMOS frequency synthesizer for the portable hybrid global navigation satellite system are presented. The large tuning range is achieved by tuning curve compensation using an improved VCO resonant tank, which reduces the power consumption and obtains better phase noise performance. The circuit is validated by simulations and fabricated in a standard 0.18 {mu}m 1P6M CMOS process. Close-loop phase noise measured is lower than -95 dBc at 200 kHz offset while the measured tuning range is 21.5% from 1.47 to 1.83 GHz. The proposed synthesizer including source coupled logic prescaler consumes 6.2 mA current from 1.8 V supply. The whole silicon required is only 0.53 mm{sup 2}. (semiconductor integrated circuits)

  2. Current control for a shunt hybrid active power filter using recursive integral PI

    Institute of Scientific and Technical Information of China (English)

    Wei ZHAO; An LUO; Ke PENG; Xia DENG

    2009-01-01

    This paper presents a current control method for a shunt hybrid active power filter(HAPF) using recursive integral Pl algorithm.The method improves the performance of the HAPF system by reducing the influence of detection accuracy,time delay of instruction current calculation and phase displacement of output filter.Fuzzy logic based set-point weighing algorithm is combined in the control scheme to enhance its robustness and anti-interference ability.The proposed algorithm is easy to implement for engineering applications and easy to compute.Experiment results have verified the validity of the proposed controller.Furthermore,the proposed recursive integral PI algorithm can also be applied in the control of periodic current as in AC drivers.

  3. Robust optimisation for self-scheduling and bidding strategies of hybrid CSP-fossil power plants

    DEFF Research Database (Denmark)

    Pousinho, H.M.I.; Contreras, J.; Pinson, P.

    2015-01-01

    This paper describes a profit-maximisation model for a hybrid concentrated solar power (CSP) producer participating in a day-ahead market with bilateral contracts, where there is no correlation between the electricity market price and the solar irradiation. Backup system coordination is included...... between the molten-salt thermal energy storage (TES) and a fossil-fuel backup to overcome solar irradiation insufficiency, but with emission allowances constrained in the backup system to mitigate carbon footprint. A robust optimisation-based approach is proposed to provide the day-ahead self......-schedule under the worst-case realisation of uncertainties due to the electricity market prices and the thermal production from the solar field (SF). These uncertainties are modelled by asymmetric prediction intervals around average values. Additionally, a budget parameter is used to parameterise the degree...

  4. An Efficient Hybrid Power Control Algorithm for Capacity Improvement of CDMA-based Fixed Wireless Applications

    CERN Document Server

    Zeeshan, Muhammad; Malik, Muhammad Yasir

    2011-01-01

    In Fixed Wireless Applications (FWA), the Code Division Multiple Access (CDMA) is the most promising candidate for wideband data access. The reason is the soft limit on the number of active mobile devices. Many Fixed Wireless Applications impose an upper bound on the BER performance which restricts the increase in number of mobile users. The number of active mobile users or Capacity is further reduced in Multipath Fading Environment (MFE). This paper presents an effective method of improving the capacity of CDMA based Fixed Wireless Networks by using a hybrid power control algorithm. The proposed scheme improves the capacity two times as compared to the conventional CDMA based networks. Simulation results have been presented to demonstrate the effectiveness of the proposed scheme.

  5. Optimal Energy Management for a Complex Hybrid Electric Vehicle:Tolerating Power-loss of Motor

    Institute of Scientific and Technical Information of China (English)

    ZHANG Pei-zhi; YIN Cheng-liang; ZHANG Yong; WU Zhi-wei

    2009-01-01

    The energy management may perform well under normal conditions, but may lead to poor behavior under abnormal situations. To tackle this problem, an optimal control strategy called rule-based equivalent fuel consumption minimization strategy (RECMS) is developed for a new complex hybrid electric vehicle (CHEV).It optimizes the energy efficiency and drive performance to cater for normal and power-loss operations of the tractive motor. Firstly, the strategy formulates a novel objective function based on the equivalent fuel concept.By accounting for the actual fuel cost, the equivalent fuel cost for the electric machines and virtual fuel cost for the drivability, the cost function is obtained. Furthermore, some penalty factors are presented to optimize the performance target. Finally, experiments for a practical CHEV are performed to validate a simulation model.Then simulations are carried out for both rule-based and RECMS. The results show that the optimal energy management is working well.

  6. Adaptive Beamforming using Hybrid Algorithm of RLS-LMS for Wireless Power Transmission

    Directory of Open Access Journals (Sweden)

    Rana Liaqat Ali, Shahid A Khan, Noman Raza, Safdar Ali, C. Xydeas, Hussan Ahmed

    2013-06-01

    Full Text Available Efficient wireless power transmission requires highly directive radiation pattern and maximum signal to noise interference ratio which can be achieved by Beamforming algorithms. A Hybrid Combination of Recursive Least Mean Square (RLS and Least Mean Square (LMS algorithm is proposed which converges to adequate results in terms of highly directive radiation pattern and maximum signal to noise interference ratio. This has been achieved by taking the favorable features of both RLS and LMS algorithms through intelligent switching between them, using a principle factor depending on minimum mean square error. Simulation results of proposed solution have verified its advantage in terms of interference rejection despite having the capability of faster convergence rate and efficient tracking of the targeted users.

  7. Magnetic amphiphilic hybrid carbon nanotubes containing N-doped and undoped sections: powerful tensioactive nanostructures

    Science.gov (United States)

    Purceno, Aluir D.; Machado, Bruno F.; Teixeira, Ana Paula C.; Medeiros, Tayline V.; Benyounes, Anas; Beausoleil, Julien; Menezes, Helvecio C.; Cardeal, Zenilda L.; Lago, Rochel M.; Serp, Philippe

    2014-11-01

    In this work, unique amphiphilic magnetic hybrid carbon nanotubes (CNTs) are synthesized and used as tensioactive nanostructures in different applications. These CNTs interact very well with aqueous media due to the hydrophilic N-doped section, whereas the undoped hydrophobic one has strong affinity for organic molecules. The amphiphilic character combined with the magnetic properties of these CNTs opens the door to completely new and exciting applications in adsorption science and catalysis. These amphiphilic N-doped CNTs can also be used as powerful tensioactive emulsification structures. They can emulsify water/organic mixtures and by a simple magnetic separation the emulsion can be easily broken. We demonstrate the application of these CNTs in the efficient adsorption of various molecules, in addition to promoting biphasic processes in three different reactions, i.e. transesterification of soybean oil, quinoline extractive oxidation with H2O2 and a metal-catalyzed aqueous oxidation of heptanol with molecular oxygen.In this work, unique amphiphilic magnetic hybrid carbon nanotubes (CNTs) are synthesized and used as tensioactive nanostructures in different applications. These CNTs interact very well with aqueous media due to the hydrophilic N-doped section, whereas the undoped hydrophobic one has strong affinity for organic molecules. The amphiphilic character combined with the magnetic properties of these CNTs opens the door to completely new and exciting applications in adsorption science and catalysis. These amphiphilic N-doped CNTs can also be used as powerful tensioactive emulsification structures. They can emulsify water/organic mixtures and by a simple magnetic separation the emulsion can be easily broken. We demonstrate the application of these CNTs in the efficient adsorption of various molecules, in addition to promoting biphasic processes in three different reactions, i.e. transesterification of soybean oil, quinoline extractive oxidation with H2O2 and

  8. Modeling and simulation of stand-alone hybrid power system with fuzzy MPPT for remote load application

    Directory of Open Access Journals (Sweden)

    Bogaraj T.

    2015-09-01

    Full Text Available Many parts of remote locations in the world are not electrified even in this Advanced Technology Era. To provide electricity in such remote places renewable hybrid energy systems are very much suitable. In this paper PV/Wind/Battery Hybrid Power System (HPS is considered to provide an economical and sustainable power to a remote load. HPS can supply the maximum power to the load at a particular operating point which is generally called as Maximum Power Point (MPP. Fuzzy Logic based MPPT (FLMPPT control method has been implemented for both Solar and Wind Power Systems. FLMPPT control technique is implemented to generate the optimal reference voltage for the first stage of DC-DC Boost converter in both the PV and Wind energy system. The HPS is tested with variable solar irradiation, temperature, and wind speed. The FLMPPT method is compared with P&O MPPT method. The proposed method provides a good maximum power operation of the hybrid system at all operating conditions. In order to combine both sources, the DC bus voltage is made constant by employing PI Controllers for the second stage of DC-DC Buck-Boost converter in both Solar and Wind Power Systems. Battery Bank is used to store excess power from Renewable Energy Sources (RES and to provide continuous power to load when the RES power is less than load power. A SPWM inverter is designed to convert DC power into AC to supply three phase load. An LC filter is also used at the output of inverter to get sinusoidal current from the PWM inverter. The entire system was modeled and simulated in Matlab/Simulink Environment. The results presented show the validation of the HPS design.

  9. Charge and bilateral discharge of battery in hybrid vehicles with ability of reactive power compensation with technology V2G

    Directory of Open Access Journals (Sweden)

    Sajad Davtalab

    2016-09-01

    Full Text Available Posing V2G theory for hybrid vehicles can create opportunities on the operation of the grid, and can even put it in row of renewable energy sources. One of the needs in the operation of power systems on which is special attention is voltage control and reactive power of grid. Hybrid cars with V2G capability can be utilized for this work and is the subject of this article.An appropriate control method for reactive power control of grid by using V2G is suggested in this article. Reactive powers, dc-link voltage and reactive power in the suggested control method are independent and can be controlled separately. Section of battery and transducer of hybrid vehicle with V2G capability have been simulated and the suggested controller has been applied to it in order to evaluate the suggested control method. The results achieved from the simulation show that reactive power injected into the grid or received from it can be controlled independent of its reactive power with appropriate transient state.

  10. Role of fast waves in the central deposition of lower hybrid power

    Science.gov (United States)

    Heikkinen, J. A.; Tala, T. J. J.; Pättikangas, T. J. H.; Piliya, A. D.; Saveliev, A. N.; Karttunen, S. J.

    1999-10-01

    In tokamaks, lower hybrid (LH) waves are routinely used for current drive and heating of plasmas. The LH waves have two modes of propagation that are called the slow and the fast wave. Usually, the lower hybrid waves are launched as slow waves into a tokamak, but during the propagation part of the wave power can be transformed to fast waves. General characteristics of the mode transformation of slow waves to fast waves are first investigated with a simple quasitoroidal ray-tracing model. Next, the effect of mode transformed LH power on the deposition profiles in a JET-like tokamak is analysed by using the fast ray-tracing code FRTC. When the launched spectrum is at small values of the toroidal refractive index (1.6 icons/Journals/Common/lesssim" ALT="lesssim" ALIGN="TOP"/> nicons/Journals/Common/phi" ALT="phi" ALIGN="TOP"/>0 icons/Journals/Common/lesssim" ALT="lesssim" ALIGN="TOP"/> 2.0), the contribution of the fast wave to the deposited power is found to be significant and responsible for most of the absorption at the centre. When nicons/Journals/Common/phi" ALT="phi" ALIGN="TOP"/>0 is large (nicons/Journals/Common/phi" ALT="phi" ALIGN="TOP"/>0 icons/Journals/Common/gtrsim" ALT="gtrsim" ALIGN="TOP"/> 2.2), the effect of the mode transformed fast waves is small or negligible. At modest central densities (ne0 ~ 0.5 × 1020 m-3), the contribution of the fast wave to the power deposition can be more than 50% in the plasma centre. In consequence, the significant amount of wave energy absorbed in the fast mode must be carefully taken into account in modelling LH current drive experiments in the future. At low central densities (ne0 icons/Journals/Common/lesssim" ALT="lesssim" ALIGN="TOP"/> 0.3 × 1020 m-3), practically no absorption of fast waves occurs.

  11. Impact of Plug-in Hybrid Electric Vehicle on Power Distribution System Considering Vehicle to Grid Technology: A Review

    Directory of Open Access Journals (Sweden)

    A. Aljanad

    2015-08-01

    Full Text Available This study presents a comprehensive review of the potential technical impacts of plug-in hybrid electric vehicles on power distribution and transmission systems. This review also presents various power quality impacts on the power system in several aspects. This review conveys a detailed analysis of electric vehicle charging strategies on electrical distribution networks. The two charging aspects (coordinated/uncoordinated and intelligent scheduling of charging are discussed in terms of their impacts on power systems. Vehicle to grid technology are investigated, elaborated and evaluated based on technical, suitability and configuration aspects.

  12. Optimization of Electric Power Systems for Off-Grid Domestic Applications: An Argument for Wind/Photovoltaic Hybrids

    Energy Technology Data Exchange (ETDEWEB)

    Jennings, W.; Green, J.

    2001-01-01

    The purpose of this research was to determine the optimal configuration of home power systems relevant to different regions in the United States. The hypothesis was that, regardless of region, the optimal system would be a hybrid incorporating wind technology, versus a photovoltaic hybrid system without the use of wind technology. The method used in this research was HOMER, the Hybrid Optimization Model for Electric Renewables. HOMER is a computer program that optimizes electrical configurations under user-defined circumstances. According to HOMER, the optimal system for the four regions studied (Kansas, Massachusetts, Oregon, and Arizona) was a hybrid incorporating wind technology. The cost differences between these regions, however, were dependent upon regional renewable resources. Future studies will be necessary, as it is difficult to estimate meteorological impacts for other regions.

  13. Optimization of Electric Power Systems for Off-Grid Domestic Applications: An Argument for Wind/Photovoltaic Hybrids

    Energy Technology Data Exchange (ETDEWEB)

    Jennings, W.; Green, J.

    2001-01-01

    The purpose of this research was to determine the optimal configuration of home power systems relevant to different regions in the United States. The hypothesis was that, regardless of region, the optimal system would be a hybrid incorporating wind technology, versus a photovoltaic hybrid system without the use of wind technology. The method used in this research was HOMER, the Hybrid Optimization Model for Electric Renewables. HOMER is a computer program that optimizes electrical configurations under user-defined circumstances. According to HOMER, the optimal system for the four regions studied (Kansas, Massachusetts, Oregon, and Arizona) was a hybrid incorporating wind technology. The cost differences between these regions, however, were dependent upon regional renewable resources. Future studies will be necessary, as it is difficult to estimate meteorological impacts for other regions.

  14. Aircraft Electric/Hybrid-Electric Power and Propulsion Workshop Perspective of the V/STOL Aircraft Systems Tech Committee

    Science.gov (United States)

    Hange, Craig E.

    2016-01-01

    This presentation will be given at the AIAA Electric Hybrid-Electric Power Propulsion Workshop on July 29, 2016. The workshop is being held so the AIAA can determine how it can support the introduction of electric aircraft into the aerospace industry. This presentation will address the needs of the community within the industry that advocates the use of powered-lift as important new technologies for future aircraft and air transportation systems. As the current chairman of the VSTOL Aircraft Systems Technical Committee, I will be presenting generalized descriptions of the past research in developing powered-lift and generalized observations on how electric and hybrid-electric propulsion may provide advances in the powered-lift field.

  15. Model-based optimal control of a hybrid power generation system consisting of photovoltaic arrays and fuel cells

    Science.gov (United States)

    Zervas, P. L.; Sarimveis, H.; Palyvos, J. A.; Markatos, N. C. G.

    Hybrid renewable energy systems are expected to become competitive to conventional power generation systems in the near future and, thus, optimization of their operation is of particular interest. In this work, a hybrid power generation system is studied consisting of the following main components: photovoltaic array (PV), electrolyser, metal hydride tanks, and proton exchange membrane fuel cells (PEMFC). The key advantage of the hybrid system compared to stand-alone photovoltaic systems is that it can store efficiently solar energy by transforming it to hydrogen, which is the fuel supplied to the fuel cell. However, decision making regarding the operation of this system is a rather complicated task. A complete framework is proposed for managing such systems that is based on a rolling time horizon philosophy.

  16. DESIGN OF THE THREE-LEVEL MULTICRITERIAL STRATEGY OF HYBRID MARINE POWER PLANT CONTROL FOR A COMBINED PROPULSION COMPLEX

    Directory of Open Access Journals (Sweden)

    V.V. Budashko

    2017-04-01

    Full Text Available Purpose. Efficiency of hybrid ships power plants (SPP combined propulsion complexes (CPC by various criteria for energy management systems strategies. Methodology. Based on the classification system topologies SPP CPC for mechanical, electrical and hybrid types of motors schematic diagrams of management strategies for the criterion of minimum power consumption are defined. Changing the technical component of the traditional approach to building hybrid ships electric power systems (SEPS SPP CPC the principle of modifying the structure of SEPS is applied with the integration of additional static alternative power source as dynamic reserve, which allowed to meet modern requirements for energy efficiency, levels of vibration, noise and degradation effects produced to SPP CPC, in all areas of the energy for the transfer of power from energy to propellers. Modeling of power transmission of energy to propellers in MatLab/Simulink is conducted, using blocks of optimization library and definition of identity markers. Results. Major advantages and disadvantages SPP CPC depending on the topology of energy distribution systems are determined. According to the chosen structure system electricity characteristics were obtained in the process of power transmission SPP CPC and power systems and their control strategies in terms of increased efficiency and eliminate these drawbacks. And finally, mathematical apparatus for research in terms of the development of methods for designing and managing SPP hybrid CPC to reduced fuel consumption, emissions into the environment and improving maintainability, flexibility and comfort level are improved. Originality. The methodology for improving SPP CPC implementation by developing methods of identification markers mutually influencing processes in SPP CPC and the development of implementing these methods of settlement and information systems. Practical value. The method enables iterative optimization parameters SPP CPC, it

  17. IMPLEMENTATION OF A REAL TIME SUPERVISORY CONTROLLER FOR AN ISOLATED HYBRID (WIND/ SOLAR/DIESEL) POWER SYSTEM

    OpenAIRE

    Boopathy C P; Dr.Sivakumar L

    2014-01-01

    In most of the developing countries like India and South Africa, there exists still many remote places (isolated from the grid); where the electrification is unavailable due to the financial aspect related to establishing the infrastructure to distribute power over a long distance and consequent high transmission losses. Authors emphasize for an Autonomous Hybrid Power Systems (AHPS), which will eradicate the problems faced by the remote places. Integration of Wind/Solar/Diesel also ensures t...

  18. Preliminary Modelling Results for an Otto Cycle/Stirling Cycle Hybrid-engine-based Power Generation System

    OpenAIRE

    Cullen, Barry; McGovern, Jim; Feidt, Michel; Petrescu, Stoian

    2009-01-01

    This paper presents preliminary data and results for a system mathematical model for a proposed Otto Cycle / Stirling Cycle hybrid-engine-based power generation system. The system is a combined cycle system with the Stirling cycle machine operating as a bottoming cycle on the Otto cycle exhaust. The application considered is that of a stationary power generation scenario wherein the Stirling cycle engine operates as a waste heat recovery device on the exhaust stream of the Otto cycle engine. ...

  19. Low-cost RAU with Optical Power Supply Used in a Hybrid RoF IEEE 802.11 Network

    Science.gov (United States)

    Kowalczyk, M.; Siuzdak, J.

    2014-09-01

    The paper presents design and implementation of a low-cost RAU (Remote Antenna Unit) device. It was designed to work in a hybrid Wi-Fi/optical network based on the IEEE 802.11b/g standard. An unique feature of the device is the possibility of optical power supply.

  20. Design of an off-grid hybrid PV/wind power system for remote mobile base station: A case study

    Directory of Open Access Journals (Sweden)

    Mulualem T. Yeshalem

    2017-01-01

    Full Text Available There is a clear challenge to provide reliable cellular mobile service at remote locations where a reliable power supply is not available. So, the existing Mobile towers or Base Transceiver Station (BTSs uses a conventional diesel generator with backup battery banks. This paper presents the solution to utilizing a hybrid of photovoltaic (PV solar and wind power system with a backup battery bank to provide feasibility and reliable electric power for a specific remote mobile base station located at west arise, Oromia. All the necessary modeling, simulation, and techno-economic evaluation are carried out using Hybrid Optimization Model for Electric Renewable (HOMER software. The best optimal system configurations namely PV/Battery and PV/Wind/Battery hybrid systems are compared with the conventional stand-alone diesel generator (DG system. Findings indicated that PV array and battery is the most economically viable option with the total net present cost (NPC of $\\$$57,508 and per unit cost of electricity (COE of $\\$$0.355. Simulation results show that the hybrid energy systems can minimize the power generation cost significantly and can decrease CO2 emissions as compared to the traditional diesel generator only. The sensitivity analysis is also carried out to analysis the effects of probable variation in solar radiation, wind speed, diesel price and average annual energy usage of the system load in the optimal system configurations.

  1. Comparing Hybrid Learning with Traditional Approaches on Learning the Microsoft Office Power Point 2003 Program in Tertiary Education

    Science.gov (United States)

    Vernadakis, Nikolaos; Antoniou, Panagiotis; Giannousi, Maria; Zetou, Eleni; Kioumourtzoglou, Efthimis

    2011-01-01

    The purpose of this study was to determine the effectiveness of a hybrid learning approach to deliver a computer science course concerning the Microsoft office PowerPoint 2003 program in comparison to delivering the same course content in the form of traditional lectures. A hundred and seventy-two first year university students were randomly…

  2. A Fuzzy-Logic Power Management Strategy Based on Markov Random Prediction for Hybrid Energy Storage Systems

    Directory of Open Access Journals (Sweden)

    Yanzi Wang

    2016-01-01

    Full Text Available Over the last few years; issues regarding the use of hybrid energy storage systems (HESSs in hybrid electric vehicles have been highlighted by the industry and in academic fields. This paper proposes a fuzzy-logic power management strategy based on Markov random prediction for an active parallel battery-UC HESS. The proposed power management strategy; the inputs for which are the vehicle speed; the current electric power demand and the predicted electric power demand; is used to distribute the electrical power between the battery bank and the UC bank. In this way; the battery bank power is limited to a certain range; and the peak and average charge/discharge power of the battery bank and overall loss incurred by the whole HESS are also reduced. Simulations and scaled-down experimental platforms are constructed to verify the proposed power management strategy. The simulations and experimental results demonstrate the advantages; feasibility and effectiveness of the fuzzy-logic power management strategy based on Markov random prediction.

  3. Heavy Traffic Feasible Hybrid Intracycle and Cyclic Sleep for Power Saving in 10G-EPON

    Directory of Open Access Journals (Sweden)

    Xintian Hu

    2014-01-01

    Full Text Available Energy consumption in optical access networks costs carriers substantial operational expense (OPEX every year and is one of contributing factors for the global warming. To reduce energy consumption in the 10-gigabit Ethernet passive optical network (10G-EPON, a hybrid intracycle and cyclic sleep mechanism is proposed in this paper. Under heavy traffic load, optical network units (ONUs can utilize short idle slots within each scheduling cycle to enter intracycle sleep without postponing data transmission. In this way, energy conservation is achieved even under heavy traffic load with quality of service (QoS guarantee. Under light traffic load, ONUs perform long cyclic sleep for several scheduling cycles. The adoption of cyclic sleep instead of intracycle sleep under light traffic load can reduce unnecessary frequent transitions between sleep and full active work caused by using intracycle sleep. Further, the Markov chain of the proposed mechanism is established. The performances of the proposed mechanism and existing approaches are analyzed quantitatively based on the chain. For the proposed mechanism, power saving ability with QoS guarantee even under heavy traffic and better power saving performance than existing approaches are verified by the quantitative analysis. Moreover, simulations validate the above conclusions based on the chain.

  4. Proposed high voltage power supply for the ITER relevant lower hybrid current drive system

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, P.K., E-mail: pramod@ipr.res.in [Institute for Plasma Research, Bhat, Gandhinagar, Gujarat (India); Kazarian, F.; Garibaldi, P.; Gassman, T. [ITER Organization, CS 90 046, 13067 Saint-Paul-Les-Durance (France); Artaud, J.F. [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France); Bae, Y.S. [National Fusion Research Institute, Daejeon (Korea, Republic of); Belo, J. [Associacao Euratom-IST, Centro de Fusao Nuclear, Lisboa (Portugal); Berger-By, G.; Bernard, J.M.; Cara, Ph. [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France); Cardinali, A.; Castaldo, C.; Ceccuzzi, S.; Cesario, R. [Associazione Euratom-ENEA sulla Fusione, CR Frascati, Rome (Italy); Decker, J.; Delpech, L.; Ekedahl, A.; Garcia, J.; Goniche, M.; Guilhem, D. [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France)

    2011-10-15

    In the framework of the EFDA task HCD-08-03-01, the ITER lower hybrid current drive (LHCD) system design has been reviewed. The system aims to generate 24 MW of RF power at 5 GHz, of which 20 MW would be coupled to the plasmas. The present state of the art does not allow envisaging a unitary output of the klystrons exceeding 500 kW, so the project is based on 48 klystron units, leaving some margin when the transmission lines losses are taken into account. A high voltage power supply (HVPS), required to operate the klystrons, is proposed. A single HVPS would be used to feed and operate four klystrons in parallel configuration. Based on the above considerations, it is proposed to design and develop twelve HVPS, based on pulse step modulator (PSM) technology, each rated for 90 kV/90 A. This paper describes in details, the typical electrical requirements and the conceptual design of the proposed HVPS for the ITER LHCD system.

  5. Comparative evaluation of biomass power generation systems in China using hybrid life cycle inventory analysis.

    Science.gov (United States)

    Liu, Huacai; Yin, Xiuli; Wu, Chuangzhi

    2014-01-01

    There has been a rapid growth in using agricultural residues as an energy source to generate electricity in China. Biomass power generation (BPG) systems may vary significantly in technology, scale, and feedstock and consequently in their performances. A comparative evaluation of five typical BPG systems has been conducted in this study through a hybrid life cycle inventory (LCI) approach. Results show that requirements of fossil energy savings, and greenhouse gas (GHG) emission reductions, as well as emission reductions of SO2 and NOx, can be best met by the BPG systems. The cofiring systems were found to behave better than the biomass-only fired system and the biomass gasification systems in terms of energy savings and GHG emission reductions. Comparing with results of conventional process-base LCI, an important aspect to note is the significant contribution of infrastructure, equipment, and maintenance of the plant, which require the input of various types of materials, fuels, services, and the consequent GHG emissions. The results demonstrate characteristics and differences of BPG systems and help identify critical opportunities for biomass power development in China.

  6. Application of Hybrid MOPSO Algorithm to Optimal Reactive Power Dispatch Problem Considering Voltage Stability

    Directory of Open Access Journals (Sweden)

    Yujiao Zeng

    2014-01-01

    Full Text Available This study presents a novel hybrid multiobjective particle swarm optimization (HMOPSO algorithm to solve the optimal reactive power dispatch (ORPD problem. This problem is formulated as a challenging nonlinear constrained multiobjective optimization problem considering three objectives, that is, power losses minimization, voltage profile improvement, and voltage stability enhancement simultaneously. In order to attain better convergence and diversity, this work presents the use of combing the classical MOPSO with Gaussian probability distribution, chaotic sequences, dynamic crowding distance, and self-adaptive mutation operator. Moreover, multiple effective strategies, such as mixed-variable handling approach, constraint handling technique, and stopping criteria, are employed. The effectiveness of the proposed algorithm for solving the ORPD problem is validated on the standard IEEE 30-bus and IEEE 118-bus systems under nominal and contingency states. The obtained results are compared with classical MOPSO, nondominated sorting genetic algorithm (NSGA-II, multiobjective evolutionary algorithm based on decomposition (MOEA/D, and other methods recently reported in the literature from the point of view of Pareto fronts, extreme, solutions and multiobjective performance metrics. The numerical results demonstrate the superiority of the proposed HMOPSO in solving the ORPD problem while strictly satisfying all the constraints.

  7. Unit Sizing and Cost Analysis of Renewable Energy based Hybrid Power Generation System - A Case Study

    Directory of Open Access Journals (Sweden)

    Nitin AGARWAL

    2014-01-01

    Full Text Available A simulation model is developed for optimal sizing and analysis of a PV-diesel-battery based hybrid power generation system with the objectives to minimize life cycle cost and CO2 emission, while maintaining the desired system autonomy. A case study of a boy’s hostel in Moradabad district is taken for analysis purposes. It has 91 rooms with a capacity of 3 boys in each room. The decision variables included in the optimization methodology are total PV area, number of PV modules of 600 Wp, diesel generator power, fuel consumption per year and number of 24 V and 150 Ah batteries. The simulation result shows that the PV percentage of 86 % and diesel penetration of 14 % gives the most optimized solution with minimum LCC of $110,547 and average CO2 emission of 28 kg/day. The developed model has been validated by comparing its results with earlier research work.doi:10.14456/WJST.2014.24

  8. High Power Antenna Design for Lower Hybrid Current Drive in MST

    Science.gov (United States)

    Thomas, M. A.; Goetz, J. A.; Kaufman, M. C.; Oliva, S. P.; Caughman, J. B. O.; Ryan, P. M.

    2003-10-01

    RF current drive has been proposed as a method for reducing the tearing fluctuations that are responsible for anomalous energy transport in the RFP. A system for launching lower hybrid slow waves at 800 MHz and n_||= 7.5 is now in operation at up to 50 kW on MST. The antenna is an enclosed interdigital line using λ/4 resonators with an opening in the cavity through which the wave is coupled to the plasma. It has an untuned VSWR of ˜2, and is instrumented on 5 of its 23 elements to allow measurement of damping length. The antenna design is being optimized for higher power handling. Improvements include larger vacuum feedthroughs, better impedance matching, and RF instrumentation on all resonators. The new antenna will be modeled in Microwave Studio^TM. The goal is a design which can handle ˜250 kW and presents a VSWR of 1.4 or better without external tuning. Full instrumentation will allow more detailed power deposition measurements.

  9. Comparative Evaluation of Biomass Power Generation Systems in China Using Hybrid Life Cycle Inventory Analysis

    Directory of Open Access Journals (Sweden)

    Huacai Liu

    2014-01-01

    Full Text Available There has been a rapid growth in using agricultural residues as an energy source to generate electricity in China. Biomass power generation (BPG systems may vary significantly in technology, scale, and feedstock and consequently in their performances. A comparative evaluation of five typical BPG systems has been conducted in this study through a hybrid life cycle inventory (LCI approach. Results show that requirements of fossil energy savings, and greenhouse gas (GHG emission reductions, as well as emission reductions of SO2 and NOx, can be best met by the BPG systems. The cofiring systems were found to behave better than the biomass-only fired system and the biomass gasification systems in terms of energy savings and GHG emission reductions. Comparing with results of conventional process-base LCI, an important aspect to note is the significant contribution of infrastructure, equipment, and maintenance of the plant, which require the input of various types of materials, fuels, services, and the consequent GHG emissions. The results demonstrate characteristics and differences of BPG systems and help identify critical opportunities for biomass power development in China.

  10. Online Junction Temperature Cycle Recording of an IGBT Power Module in a Hybrid Car

    Directory of Open Access Journals (Sweden)

    Marco Denk

    2015-01-01

    Full Text Available The accuracy of the lifetime calculation approach of IGBT power modules used in hybrid-electric powertrains suffers greatly from the inaccurate knowledge of application typical load-profiles. To verify the theoretical load-profiles with data from the field this paper presents a concept to record all junction temperature cycles of an IGBT power module during its operation in a test vehicle. For this purpose the IGBT junction temperature is measured with a modified gate driver that determines the temperature sensitive IGBT internal gate resistor by superimposing the negative gate voltage with a high-frequency identification signal. An integrated control unit manages the TJ measurement during the regular switching operation, the exchange of data with the system controller, and the automatic calibration of the sensor system. To calculate and store temperature cycles on a microcontroller an online Rainflow counting algorithm was developed. The special feature of this algorithm is a very accurate extraction of lifetime relevant information with a significantly reduced calculation and storage effort. Until now the recording concept could be realized and tested within a laboratory voltage source inverter. Currently the IGBT driver with integrated junction temperature measurement and the online cycle recording algorithm is integrated in the voltage source inverter of first test vehicles. Such research will provide representative load-profiles to verify and optimize the theoretical load-profiles used in today’s lifetime calculation.

  11. A Single-Degree-of-Freedom Energy Optimization Strategy for Power-Split Hybrid Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Chaoying Xia

    2017-07-01

    Full Text Available This paper presents a single-degree-of-freedom energy optimization strategy to solve the energy management problem existing in power-split hybrid electric vehicles (HEVs. The proposed strategy is based on a quadratic performance index, which is innovatively designed to simultaneously restrict the fluctuation of battery state of charge (SOC and reduce fuel consumption. An extended quadratic optimal control problem is formulated by approximating the fuel consumption rate as a quadratic polynomial of engine power. The approximated optimal control law is obtained by utilizing the solution properties of the Riccati equation and adjoint equation. It is easy to implement in real-time and the engineering significance is explained in details. In order to validate the effectiveness of the proposed strategy, the forward-facing vehicle simulation model is established based on the ADVISOR software (Version 2002, National Renewable Energy Laboratory, Golden, CO, USA. The simulation results show that there is only a little fuel consumption difference between the proposed strategy and the Pontryagin’s minimum principle (PMP-based global optimal strategy, and the proposed strategy also exhibits good adaptability under different initial battery SOC, cargo mass and road slope conditions.

  12. Modeling and analysis of dynamic behavior of hybrid wind-diesel power plants

    Science.gov (United States)

    Garcia, Sergio Leonardo

    This thesis develops small-signal and large-signal models to investigate the dynamic performance of a hybrid wind-diesel energy system interfaced to a utility grid. The study system comprises a 3.5-MVA diesel-generator unit operating in parallel with a 750-kVA variable-speed, squirrel-cage induction generator, wind unit. The wind unit is interfaced to the power network through a back-to-back voltage-sourced converter system. The controllers of the machine-side converter regulate the mechanical torque and the shaft speed of the induction generator to obtain maximum power production under fluctuating wind-speed conditions. The controllers of the grid-side converter maintain the dc-link voltage and the ac-side converter terminal voltage within the specified limits and ensure delivery of the captured wind power to the network. The diesel-generator unit is equipped with excitation and governor systems to compensate for (i) output power changes of the wind unit due to the intermittent nature of the wind, and (ii) changes in the load demand. Based on small-signal (eigen) analyses in the MATLABRTM software environment, the controller parameters of the wind and the diesel units are selected to guarantee (i) minimization of transients due to switch over between two consecutive modes of operation, (ii) voltage/angle stability during islanded (autonomous) mode of operation, and (iii) local load requirements in terms of voltage and real/reactive power. The results obtained from time-domain simulations, in the PSCAD RTM/EMTDCRTM software environment, demonstrate that proper adjustment of the controllers of the wind and diesel units promote "ride-through" capability in the event of (i) pre-planned transitions between different modes of operation, (ii) pre-planned islanding and re-connection of the units to the power network, and (iii) short circuits, accidental islanding and subsequent re-connection attempts to the network. The developed eigen analysis tool is structured to

  13. A novel power control strategy of Modular Multi-level Converter in HVDC-AC hybrid transmission systems for passive networks

    DEFF Research Database (Denmark)

    Hu, Zhenda; Wu, Rui; Yang, Xiaodong;

    2014-01-01

    With the development of High Voltage DC Transmission (HVDC) technology, there will be more and more HVDC-AC hybrid transmission system in the world. A basic challenge in HVDC-AC hybrid transmission systems is to optimize the power sharing between DC and AC lines, which become more severe when...... supplying power for passive networks, as the surplus power can only flow back to power grids through the AC lines. To deal with this issue, it demands not only accurate system capability design but also flexible power control strategy of power converters in VSC-HVDC. This paper proposes a novel power...

  14. Solar central receiver hybrid power system, Phase I. Volume 2. Conceptual design. Final technical report, October 1978-August 1979

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-09-01

    The objectives of this study were to develop a hybrid power system design that (1) produces minimum cost electric power, (2) minimizes the capital investment and operating cost, (3) permits capacity displacement, (4) and achieves utility acceptance for market penetration. We have met the first three of these objectives and therefore believe that the fourth, utility acceptance, will become a reality. These objectives have been met by utilizing the Martin Marietta concept that combines the alternate central receiver power system design and a high-temperature salt primary heat transfer fluid and thermal storage media system with a fossil-fired nonsolar energy source. Task 1 reviewed the requirements definition document and comments and recommendations were provided to DOE/San Francisco. Task 2 consisted of a market analysis to evaluate the potential market of solar hybrid power plants. Twenty-two utilities were selected within nine regions of the country. Both written and verbal correspondence was used to assess solar hybrid power plants with respect to the utilities' future requirements and plans. The parametric analysis of Task 3 evaluated a wide range of subsystem configurations and sizes. These analyses included subsystems from the solar standalone alternate central receiver power system using high-temperature molten salt and from fossil fuel nonsolar subsystems. Task 4, selection of the preferred commerical system configuration, utilized the parametric analyses developed in Task 3 to select system and subsystem configurations for the commercial plant design. Task 5 developed a conceptual design of the selected commercial plant configuration and assessed the related cost and performance. Task 6 assessed the economics and performance of the selected configuration as well as future potential improvements or limitations of the hybrid power plants.

  15. Optimization of a hybrid electric power system design for large commercial buildings: An application design guide

    Science.gov (United States)

    Lee, Keun

    Renewable energy in different forms has been used in various applications for survival since the beginning of human existence. However, there is a new dire need to reevaluate and recalibrate the overall energy issue both nationally and globally. This includes, but is not limited to, the finite availability of fossil fuel, energy sustainability with an increasing demand, escalating energy costs, environmental impact such as global warming and green-house gases, to name a few. This dissertation is primarily focused and related to the production and usage of electricity from non-hydro renewable sources. Among non-hydro renewable energy sources, electricity generation from wind and solar energy are the fastest-growing technologies in the United States and in the world. However, due to the intermittent nature of such renewable sources, energy storage devices are required to maintain proper operation of the grid system and in order to increase reliability. A hybrid system, as the name suggests, is a combination of different forms of non-renewable and renewable energy generation, with or without storage devices. Hybrid systems, when applied properly, are able to improve reliability and enhance stability, reduce emissions and noise pollution, provide continuous power, increase operation life, reduce cost, and efficiently use all available energy. In the United States (U.S.), buildings consume approximately 40% of the total primary energy and 74% of the total electricity. Therefore, reduction of energy consumption and improved energy efficiency in U.S. buildings will play a vital role in the overall energy picture. Electrical energy usage for any such building varies widely depending on age (construction technique), electricity and natural gas usage, appearance, location and climate. In this research, a hybrid system including non-renewable and renewable energy generation with storage devices specifically for building applications, is studied in detail. This research deals

  16. The Presentation of a Two Stages Model for an Optimum Operation of a Hybrid System of Wind-Pumped Storage Power Plant in the Power Market Environment

    Directory of Open Access Journals (Sweden)

    Mehdi Akbarpour

    2012-11-01

    Full Text Available In this study we present a new method in power market environment. One of the weaknesses in the utilization of wind units is severe dependence of output power level on wind. However, considering the high uncertainty in the prediction of wind speed and wind forecast unit production capacity is also having an error. Also, regarding to the uncontrollable generators of this type, it is better to use combined systems for utilization. This study presents a new model based on the a two stage for an optimum operation of a hybrid system of windpumped storage power plant in the power market environment that causes to provide a successful presentation condition in market environments for the producers of wind power. In the suggestive hybrid system of windpumped storage power plant of this study the modeling is done in two stages for the optimum presence in power market environment with the a most possible benefit. At first, the suggestive model is optimized regarding to uncertainty in the prediction of power price and producing the wind power, for presenting the suggestion of power to market, in order to gain the most benefit. At the second stage, the suggestive model is optimized regarding to uncertainty in producing wind power, in order to gain the most benefit and paying the least penalty for unbalancing in market for operation of the system. In this study, the Particle Swarm Optimization algorithm (PSO is used for optimization. At the end of a model example for applying the results of the proposed model will be examined and analyzes the results. Results show that the model is an appropriate method for the operation of this combined system in market environment.

  17. Application of hybrid life cycle approaches to emerging energy technologies--the case of wind power in the UK.

    Science.gov (United States)

    Wiedmann, Thomas O; Suh, Sangwon; Feng, Kuishuang; Lenzen, Manfred; Acquaye, Adolf; Scott, Kate; Barrett, John R

    2011-07-01

    Future energy technologies will be key for a successful reduction of man-made greenhouse gas emissions. With demand for electricity projected to increase significantly in the future, climate policy goals of limiting the effects of global atmospheric warming can only be achieved if power generation processes are profoundly decarbonized. Energy models, however, have ignored the fact that upstream emissions are associated with any energy technology. In this work we explore methodological options for hybrid life cycle assessment (hybrid LCA) to account for the indirect greenhouse gas (GHG) emissions of energy technologies using wind power generation in the UK as a case study. We develop and compare two different approaches using a multiregion input-output modeling framework - Input-Output-based Hybrid LCA and Integrated Hybrid LCA. The latter utilizes the full-sized Ecoinvent process database. We discuss significance and reliability of the results and suggest ways to improve the accuracy of the calculations. The comparison of hybrid LCA methodologies provides valuable insight into the availability and robustness of approaches for informing energy and environmental policy.

  18. Power and temperature control of fluctuating biomass gas fueled solid oxide fuel cell and micro gas turbine hybrid system

    Science.gov (United States)

    Kaneko, T.; Brouwer, J.; Samuelsen, G. S.

    This paper addresses how the power and temperature are controlled in a biomass gas fueled solid oxide fuel cell (SOFC) and micro gas turbine (MGT) hybrid system. A SOFC and MGT dynamic model are developed and used to simulate the hybrid system performance operating on biomass gas. The transient behavior of both the SOFC and MGT are discussed in detail. An unstable power output is observed when the system is fed biomass gas. This instability is due to the fluctuation of gas composition in the fuel. A specially designed fuel controller succeeded not only in allowing the hybrid system to follow a step change of power demand from 32 to 35 kW, but also stably maintained the system power output at 35 kW. In addition to power control, fuel cell temperature is controlled by introduction and use of a bypass valve around the recuperator. By releasing excess heat to the exhaust, the bypass valve provided the control means to avoid the self-exciting behavior of system temperature and stabilized the temperature of SOFC at 850 °C.

  19. Techno-economic analysis of hybrid power system sizing applied to small desalination plants for sustainable operation

    Directory of Open Access Journals (Sweden)

    R. Nagaraj

    2016-12-01

    Full Text Available Water and energy are two inseparable commodities that govern the lives of humanity and promote civilization. Energy can be used to produce water in case of scarcity in water. Ironically most of the places that are water stressed are also energy stressed. The cost of extending grid power may be prohibitively high in those cases. Rural/remote locations like hills and islands multiply the problem to a larger magnitude. Use of renewable sources like solar, wind, biomass and other locally available energy sources is the only solution. But these renewable sources are of intermittent nature and have poor availability. Hence, it is practically difficult to produce water with a single source of energy. Naturally, combining two or more sources of energy, known as hybrid power system, is the next available option. This paper carries out a techno-economic analysis of various sizing combinations of systems with solar photo voltaic, wind energy and stored energy in batteries for production of drinking water from a brackish water source. The system can operate the RO plant whenever the power is available, produce drinking water and store in a tank. This paper analyses the model of the entire hybrid power system in MATLAB to simulate the performance of the hybrid power system for different combinations of capacities. Results of the analysis under various input conditions are analyzed.

  20. A Hybrid Forecasting Model Based on Empirical Mode Decomposition and the Cuckoo Search Algorithm: A Case Study for Power Load

    Directory of Open Access Journals (Sweden)

    Jiani Heng

    2016-01-01

    Full Text Available Power load forecasting always plays a considerable role in the management of a power system, as accurate forecasting provides a guarantee for the daily operation of the power grid. It has been widely demonstrated in forecasting that hybrid forecasts can improve forecast performance compared with individual forecasts. In this paper, a hybrid forecasting approach, comprising Empirical Mode Decomposition, CSA (Cuckoo Search Algorithm, and WNN (Wavelet Neural Network, is proposed. This approach constructs a more valid forecasting structure and more stable results than traditional ANN (Artificial Neural Network models such as BPNN (Back Propagation Neural Network, GABPNN (Back Propagation Neural Network Optimized by Genetic Algorithm, and WNN. To evaluate the forecasting performance of the proposed model, a half-hourly power load in New South Wales of Australia is used as a case study in this paper. The experimental results demonstrate that the proposed hybrid model is not only simple but also able to satisfactorily approximate the actual power load and can be an effective tool in planning and dispatch for smart grids.

  1. Decentralized Method for Load Sharing and Power Management in a PV/Battery Hybrid Source Islanded Microgrid

    DEFF Research Database (Denmark)

    Karimi, Yaser; Oraee, Hashem; Golsorkhi, Mohammad;

    2017-01-01

    This paper proposes a new decentralized power management and load sharing method for a photovoltaic based islanded microgrid consisting of various PV units, battery units and hybrid PV/battery units. Unlike the previous methods in the literature, there is no need to communication among the units...... and the proposed method is not limited to the systems with separate PV and battery units or systems with only one hybrid unit. The proposed method takes into account the available PV power and battery conditions of the units to share the load among them. To cover all possible conditions of the microgrid......, the operation of each unit is divided into five states and modified active power-frequency droop functions are used according to operating states. The frequency level is used as trigger for switching between the states. Efficacy of the proposed method in different load, PV generation and battery conditions...

  2. Implementation of a robust hybrid rotary-translational vibration energy harvester for autonomous self-powered acceleration measurement

    Science.gov (United States)

    Payne, Owen R.; Vandewater, Luke A.; Ung, Chandarin; Moss, Scott D.

    2015-04-01

    In this paper, a self-powered wireless sensor node utilising ambient vibrations for power is described. The device consists of a vibration energy harvester, power management system, microcontroller, accelerometer, RF transmitter/receiver and external LED indicators. The vibration energy harvester is adapted from a previously reported hybrid rotary-translational device and uses a pair of copper coil transducers to convert the mechanical energy of a magnetic sphere into usable electricity. The device requires less than 0.8 mW of power to operate continuously in its present setup (with LED indicators off) while measuring acceleration at a sample rate of 200 Hz, with the power source providing 39.7 mW of power from 500 mg excitations at 5.5 Hz. When usable input energy is removed, the device will continue to transmit data for more than 5 minutes.

  3. Hybrid Pressure Retarded Osmosis−Membrane Distillation (PRO−MD) Process for Osmotic Power and Clean Water Generation

    KAUST Repository

    Han, Gang

    2015-05-20

    A novel pressure retarded osmosis−membrane distillation (PRO−MD) hybrid process has been experimentally conceived for sustainable production of renewable osmotic power and clean water from various waters. The proposed PRO−MD system may possess unique advantages of high water recovery rate, huge osmotic power generation, well controlled membrane fouling, and minimal environmental impacts. Experimental results show that the PRO−MD hybrid process is promising that not only can harvest osmotic energy from freshwater but also from wastewater. When employing a 2 M NaCl MD concentrate as the draw solution, ultrahigh power densities of 31.0 W/m2 and 9.3 W/m2 have been demonstrated by the PRO subsystem using deionized water and real wastewater brine as the feeds, respectively. Simultaneously, high purity potable water with a flux of 32.5−63.1 L/(m2.h) can be produced by the MD subsystem at 40−60 °C without any detrimental effects of fouling. The energy consumption in the MD subsystem might be further reduced by applying a heat exchanger in the hybrid system and using low-grade heat or solar energy to heat up the feed solution. The newly developed PRO−MD hybrid process would provide insightful guidelines for the exploration of alternative green technologies for renewable osmotic energy and clean water production.

  4. Studies on the Growth Habits and Characteristics of Two Polyploid Indica-Japonica Hybrid Rice with Powerful Heterosis

    Institute of Scientific and Technical Information of China (English)

    SONG Zhao-jian; DU Chao-qun; DAI Bing-cheng; CHEN Dong-ling; CHEN Jian-guo; CAI De-tian

    2007-01-01

    Based on a series of polyploid indica-japonica hybrid plant lines obtained from a new breeding strategy of using double predominance of wide cross and polyploidization to breed super rice, two polyploid indica-japonica hybrids, PSR073 and PSR120 were studied in their growth periods to show the powerful heterosis in a larger scale and to study the characteristics of polyploid indica-japonica hybrids more elaborately. The leaf age, tiller growth, flowering habits, and agronomic traits of them were observed to analyze their growth habits and characteristics. The results showed that the.agronomic traits of PSR073 and PSR 120, such as the plant height, panicle length, grain length, grain width, and 1000-grain weight, all acquired obvious predominance of polyploidy, and that the seed setting rate was more than 83%. No significant difference was observed between the two tetraploids and common diploids in the leaf age, tiller growth, and flowering habits. It was concluded that the characteristics of the two powerful heterosis polyploid hybrids were different from those of the polyploid rice reported earlier. Wide cross and polyploidization had no negative effects on their growth habits and characteristics; on the contrary these had powerful heterosis. This had provided theoretic and practical evidences for their application to agricultural production.

  5. The shallow water equations as a hybrid flow model for the numerical and experimental analysis of hydro power stations

    Energy Technology Data Exchange (ETDEWEB)

    Ostermann, Lars; Seidel, Christian [AG Regenerative Energien, Institut für Statik, TU Braunschweig, Beethovenstrasse 51, 38106 Braunschweig (Germany)

    2015-03-10

    The numerical analysis of hydro power stations is an important method of the hydraulic design and is used for the development and optimisation of hydro power stations in addition to the experiments with the physical submodel of a full model in the hydraulic laboratory. For the numerical analysis, 2D and 3D models are appropriate and commonly used.The 2D models refer mainly to the shallow water equations (SWE), since for this flow model a large experience on a wide field of applications for the flow analysis of numerous problems in hydraulic engineering already exists. Often, the flow model is verified by in situ measurements. In order to consider 3D flow phenomena close to singularities like weirs, hydro power stations etc. the development of a hybrid fluid model is advantageous to improve the quality and significance of the global model. Here, an extended hybrid flow model based on the principle of the SWE is presented. The hybrid flow model directly links the numerical model with the experimental data, which may originate from physical full models, physical submodels and in-situ measurements. Hence a wide field of application of the hybrid model emerges including the improvement of numerical models and the strong coupling of numerical and experimental analysis.

  6. Second Order Cone Programming (SOCP) Relaxation Based Optimal Power Flow with Hybrid VSC-HVDC Transmission and Active Distribution Networks

    DEFF Research Database (Denmark)

    Ding, Tao; Li, Cheng; Yang, Yongheng

    2017-01-01

    The detailed topology of renewable resource bases may have the impact on the optimal power flow of the VSC-HVDC transmission network. To address this issue, this paper develops an optimal power flow with the hybrid VSC-HVDC transmission and active distribution networks to optimally schedule...... the generation output and voltage regulation of both networks, which leads to a non-convex programming model. Furthermore, the non-convex power flow equations are based on the Second Order Cone Programming (SOCP) relaxation approach. Thus, the proposed model can be relaxed to a SOCP that can be tractably solved...

  7. Feasibility of pico-hydro and photovoltaic hybrid power systems for remote villages in Cameroon

    Energy Technology Data Exchange (ETDEWEB)

    Nfah, E.M. [Laboratoire d' Automatique et d' Informatique Appliquee, I.U.T. Fotso Victor, P.O. Box 134, Bandjoun, University of Dschang (Cameroon); Ngundam, J.M. [Automation and Control Laboratory, School of Engineering, P.O. Box 8390, University of Yaounde I (Cameroon)

    2009-06-15

    Pico-hydro (pH) and photovoltaic (PV) hybrid systems incorporating a biogas generator have been simulated for remote villages in Cameroon using a load of 73 kWh/day and 8.3 kWp. Renewable energy systems were simulated using HOMER, the load profile of a hostel in Cameroon, the solar insolation of Garoua and the flow of river Mungo. For a 40% increase in the cost of imported power system components, the cost of energy was found to be either 0.352 EUR/kWh for a 5 kW pico-hydro generator with 72 kWh storage or 0.396 EUR/kWh for a 3 kWp photovoltaic generator with 36 kWh storage. These energy costs were obtained with a biomass resource cost of 25 EUR/tonne. The pH and PV hybrid systems both required the parallel operation of a 3.3 kW battery inverter with a 10 kW biogas generator. The pH/biogas/battery systems simulated for villages located in the south of Cameroon with a flow rate of at least 92 l/s produced lower energy costs than PV/biogas/battery systems simulated for villages in the north of Cameroon with an insolation level of at least 5.55 kWh/m{sup 2}/day. For a single-wire grid extension cost of 5000 EUR/km, operation and maintenance costs of 125 EUR/yr/km and a grid power price of 0.1 EUR/kWh, the breakeven grid extension distances were found to be 12.9 km for pH/biogas/battery systems and 15.2 km for PV/biogas/battery systems respectively. Investments in biogas based renewable energy systems could thus be considered in the National Energy Action Plan of Cameroon for the supply of energy to key sectors involved in poverty alleviation. (author)

  8. Worldwide wind/diesel hybrid power system study: Potential applications and technical issues

    Energy Technology Data Exchange (ETDEWEB)

    King, W.R.; Johnson, B.L. III (Science Applications International Corp., McLean, VA (USA))

    1991-04-01

    The world market potential for wind/diesel hybrid technology is a function of the need for electric power, the availability of sufficient wind resource to support wind/diesel power, and the existence of buyers with the financial means to invest in the technology. This study includes data related to each of these three factors. This study does not address market penetration, which would require analysis of application specific wind/diesel economics. Buyer purchase criteria, which are vital to assessing market penetration, are discussed only generally. Countries were screened for a country-specific market analysis based on indicators of need and wind resource. Both developed countries and less developed countries'' (LDCs) were screened for wind/diesel market potential. Based on the results of the screening, ten countries showing high market potential were selected for more extensive market analyses. These analyses provide country-specific market data to guide wind/diesel technology developers in making design decisions that will lead to a competitive product. Section 4 presents the country-specific data developed for these analyses, including more extensive wind resource characterization, application-specific market opportunities, business conditions, and energy market characterizations. An attempt was made to identify the potential buyers with ability to pay for wind/diesel technology required to meet the application-specific market opportunities identified for each country. Additionally, the country-specific data are extended to corollary opportunities in countries not covered by the study. Section 2 gives recommendations for wind/diesel research based on the findings of the study. 86 refs.

  9. Solar hybrid power plants: Solar energy contribution in reaching full dispatchability and firmness

    Science.gov (United States)

    Servert, Jorge F.; López, Diego; Cerrajero, Eduardo; Rocha, Alberto R.; Pereira, Daniel; Gonzalez, Lucía

    2016-05-01

    Renewable energies for electricity generation have always been considered as a risk for the electricity system due to its lack of dispatchability and firmness. Renewable energies penetration is constrained to strong grids or else its production must be limited to ensure grid stability, which is kept by the usage of hydropower energy or fossil-fueled power plants. CSP technology has an opportunity to arise not only as a dispatchable and firm technology, but also as an alternative that improves grid stability. To achieve that objective, solar hybrid configurations are being developed, being the most representative three different solutions: SAPG, ISCC and HYSOL. A reference scenario in Kingdom of Saudi Arabia (KSA) has been defined to compare these solutions, which have been modelled, simulated and evaluated in terms of dispatchability and firmness using ratios defined by the authors. The results show that: a) SAPG obtains the highest firmness KPI values, but no operation constraints have been considered for the coal boiler and the solar energy contribution is limited to 1.7%, b) ISCC provides dispatchable and firm electricity production but its solar energy contribution is limited to a 6.4%, and c) HYSOL presents the higher solar energy contribution of all the technologies considered: 66.0% while providing dispatchable and firm generation in similar conditions as SAPG and ISCC.

  10. Hybrid wind-PV grid connected power station case study: Al Tafila, Jordan

    Energy Technology Data Exchange (ETDEWEB)

    El-Tous, Yousif [Department of Electrical Engineering/Faculty of Engineering Technology/ Al-Balqa' Applied University, Amman, P.O.Box (15008), Marka Ashamalia (Jordan); Al-Battat, Saleh [Department of substation maintenance and protection, National Electric Power Company (NEPCO), Amman (Jordan); Abdel Hafith, Sandro [Department of technical support and project supervision/Integrated power systems co., Amman (Jordan)

    2012-07-01

    In this paper, we are providing an attempt to highlight the importance of renewable energy, more specifically, the one produced from a wind-solar hybrid system. This purpose will be achieved through providing a detailed case study for such system that would be applied in Al-Tafila, Jordan. First and foremost site assessment has been conducted based on an intensive literature review for the data available regarding the availability of wind and solar energy in Jordan and resulted in the selection of Al-Tafila 2 district as the best option among all. Then, the components of the power station and its size have been selected based on specific criteria that make the station as much efficient and competitive as possible. To obtain the output of the different components with respect to the demand for a period of 25 years, a system model was built using HOMER. Finally, the total capital cost of the system was calculated and resulted to be (63400168) $ and with a cost of energy of (0.053) $/kWh which is a very competitive and feasible cost compared to similar international projects and to the conventional energy price.

  11. An innovative ecological hybrid refrigeration cycle for high power refrigeration facility

    Directory of Open Access Journals (Sweden)

    Cyklis Piotr

    2015-09-01

    Full Text Available Searching for new refrigerants is one of the most significant scientific problems in refrigeration. There are ecological refrigerants commonly known: H2O and CO2. H2O and CO2 known as natural refrigerants, but they have problems:a high freezing point of H2O and a low triple point of CO2. These problems can be solved by the application of a hybrid sorption-compression refrigeration cycle. The cycle combines the application possibility of H2O in the high temperature sorption stage and the low temperature application of CO2 in the compression stage. This solution gives significant energy savings in comparison with the two-stage compressor cycle and with the one-stage transcritical CO2 cycle. Besides, the sorption cycle may be powered by low temperature waste heat or renewable heat. This is an original idea of the authors. In the paper an analysis of the possible extension of this solution for high capacity industrial refrigeration is presented. The estimated energy savings as well as TEWI (Total Equivalent Warming Impact index for ecological gains are calculated.

  12. Hybrid wind-PV grid connected power station case study: Al Tafila, Jordan

    Directory of Open Access Journals (Sweden)

    Yousif El-Tous, Saleh Al-Battat, Sandro Abdel Hafith

    2012-01-01

    Full Text Available In this paper, we are providing an attempt to highlight the importance of renewable energy, more specifically, the one produced from a wind-solar hybrid system. This purpose will be achieved through providing a detailed case study for such system that would be applied in Al-TafilaJordan. First and foremost site assessment has been conducted based on an intensive literature review for the data available regarding the availability of wind and solar energy in Jordan and resulted in the selection of Al-Tafila 2 district as the best option among all. Then, the components of the power station and its size have been selected based on specific criteria that make the station as much efficient and competitive as possible. To obtain the output of the different components with respect to the demand for a period of 25 years, a system model was built using HOMER. Finally, the total capital cost of the system was calculated and resulted to be (63400168 $ and with a cost of energy of (0.053 $/kWh which is a very competitive and feasible cost compared to similar international projects and to the conventional energy price.

  13. Equivalence of optical and electrical noise equivalent power of hybrid NbTiN-Al microwave kinetic inductance detectors

    Energy Technology Data Exchange (ETDEWEB)

    Janssen, R. M. J., E-mail: r.m.j.janssen@tudelft.nl [Kavli Institute of Nanoscience, Faculty of Applied Sciences, Delft University of Technology, Lorentzweg 1, 2628CJ Delft (Netherlands); Endo, A. [Kavli Institute of Nanoscience, Faculty of Applied Sciences, Delft University of Technology, Lorentzweg 1, 2628CJ Delft (Netherlands); Department of Microelectronics, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), Delft University of Technology, Mekelweg 4, 2628 CD Delft (Netherlands); Visser, P. J. de [Kavli Institute of Nanoscience, Faculty of Applied Sciences, Delft University of Technology, Lorentzweg 1, 2628CJ Delft (Netherlands); SRON Netherlands Institute for Space Research, Sorbonnelaan 2, 3584CA Utrecht (Netherlands); Klapwijk, T. M. [Kavli Institute of Nanoscience, Faculty of Applied Sciences, Delft University of Technology, Lorentzweg 1, 2628CJ Delft (Netherlands); Physics Department, Moscow State Pedagogical University, Moscow 119991 (Russian Federation); Baselmans, J. J. A. [SRON Netherlands Institute for Space Research, Sorbonnelaan 2, 3584CA Utrecht (Netherlands)

    2014-11-10

    We have measured and compared the response of hybrid NbTiN-Al Microwave Kinetic Inductance Detectors (MKIDs) to changes in bath temperature and illumination by sub-mm radiation. We show that these two stimulants have an equivalent effect on the resonance feature of hybrid MKIDs. We determine an electrical noise equivalent power (NEP) from the measured temperature responsivity, quasiparticle recombination time, superconducting transition temperature, and noise spectrum, all of which can be measured in a dark environment. For the two hybrid NbTiN-Al MKIDs studied in detail, the electrical NEP is within a factor of two of the optical NEP, which is measured directly using a blackbody source.

  14. Study of a solar PV-diesel-battery hybrid power system for a remotely located population near Rafha, Saudi Arabia

    Energy Technology Data Exchange (ETDEWEB)

    Rehman, Shafiqur; Al-Hadhrami, Luai M. [Center for Engineering Research, Research Institute, King Fahd University of Petroleum and Minerals, KFUPM Box 767, Dhahran-31261 (Saudi Arabia)

    2010-12-15

    This study presents a PV-diesel hybrid power system with battery backup for a village being fed with diesel generated electricity to displace part of the diesel by solar. The hourly solar radiation data measured at the site along with PV modules mounted on fixed foundations, four generators of different rated powers, diesel prices of 0.2-1.2US$/l, different sizes of batteries and converters were used to find an optimal power system for the village. It was found that a PV array of 2000 kW and four generators of 1250, 750, 2250 and 250 kW; operating at a load factor of 70% required to run for 3317 h/yr, 4242 h/yr, 2820 h/yr and 3150 h/yr, respectively; to produce a mix of 17,640 MWh of electricity annually and 48.33 MWh per day. The cost of energy (COE) of diesel only and PV/diesel/battery power system with 21% solar penetration was found to be 0.190$/kWh and 0.219$/kWh respectively for a diesel price of 0.2$/l. The sensitivity analysis showed that at a diesel price of 0.6$/l the COE from hybrid system become almost the same as that of the diesel only system and above it, the hybrid system become more economical than the diesel only system. (author)

  15. Performance analysis of different ORC configurations for thermal energy and LNG cold energy hybrid power generation system

    Science.gov (United States)

    Sun, Zhixin; Wang, Feng; Wang, Shujia; Xu, Fuquan; Lin, Kui

    2017-01-01

    This paper presents a thermal energy and Liquefied natural gas (LNG) cold energy hybrid power generation system. Performances of four different Organic Rankine cycle (ORC) configurations (the basic, the regenerative, the reheat and the regenerative-reheat ORCs) are studied based on the first and the second law of thermodynamics. Dry organic fluid R245fa is selected as the typical working fluid. Parameter analysis is also conducted in this paper. The results show that regeneration could not increase the thermal efficiency of the thermal and cold energy hybrid power generation system. ORC with the reheat process could produce more specific net power output but it may also reduce the system thermal efficiency. The basic and the regenerative ORCs produce higher thermal efficiency while the regenerative-reheat ORC performs best in the exergy efficiency. A preheater is necessary for the thermal and cold energy hybrid power generation system. And due to the presence of the preheater, there will be a step change of the system performance as the turbine inlet pressure rises.

  16. Voltage Profile Enhancement and Reduction of Real Power loss by Hybrid Biogeography Based Artificial Bee Colony algorithm

    Directory of Open Access Journals (Sweden)

    K. Lenin

    2014-04-01

    Full Text Available This paper presents Hybrid Biogeography algorithm for solving the multi-objective reactive power dispatch problem in a power system. Real Power Loss minimization and maximization of voltage stability margin are taken as the objectives. Artificial bee colony optimization (ABC is quick and forceful algorithm for global optimization. Biogeography-Based Optimization (BBO is a new-fangled biogeography inspired algorithm. It mainly utilizes the biogeography-based relocation operator to share the information among solutions. In this work, a hybrid algorithm with BBO and ABC is projected, and named as HBBABC (Hybrid Biogeography based Artificial Bee Colony Optimization, for the universal numerical optimization problem. HBBABC merge the searching behavior of ABC with that of BBO. Both the algorithms have different solution probing tendency like ABC have good exploration probing tendency while BBO have good exploitation probing tendency.  HBBABC used to solve the reactive power dispatch problem and the proposed technique has been tested in standard IEEE30 bus test system.

  17. A novel coordinated control strategy considering power smoothing for a hybrid photovoltaic/battery energy storage system

    Institute of Scientific and Technical Information of China (English)

    DAUD Muhamad Zalani; MOHAMED Azah; HANNAN M A

    2016-01-01

    This work presents a novel coordinated control strategy of a hybrid photovoltaic/battery energy storage (PV/BES) system. Different controller operation modes are simulated considering normal, high fluctuation and emergency conditions. When the system is grid-connected, BES regulates the fluctuated power output which ensures smooth net injected power from the PV/BES system. In islanded operation, BES system is transferred to single master operation during which the frequency and voltage of the islanded microgrid are regulated at the desired level. PSCAD/EMTDC simulation validates the proposed method and obtained favorable results on power set-point tracking strategies with very small deviations of net output power compared to the power set-point. The state-of-charge regulation scheme also very effective with SOC has been regulated between 32% and 79% range.

  18. Establishment of quality, reliability and design standards for low, medium, and high power microwave hybrid microcircuits

    Science.gov (United States)

    Robinson, E. A.

    1973-01-01

    Quality, reliability, and design standards for microwave hybrid microcircuits were established. The MSFC Standard 85M03926 for hybrid microcircuits was reviewed and modifications were generated for use with microwave hybrid microcircuits. The results for reliability tests of microwave thin film capacitors, transistors, and microwave circuits are presented. Twenty-two microwave receivers were tested for 13,500 unit hours. The result of 111,121 module burn-in and operating hours for an integrated solid state transceiver module is reported.

  19. Status and modeling improvements of hybrid wind/PV/diesel power systems for Brazilian applications

    Energy Technology Data Exchange (ETDEWEB)

    McGowan, J.G.; Manwell, J.F.; Avelar, C. [Univ. of Massachusetts, Amherst, MA (United States); Taylor, R. [National Renewable Energy Lab., Golden, CO (United States)

    1997-12-31

    This paper present a summary of the ongoing work on the modeling and system design of hybrid wind/PV/diesel systems for two different sites in the Amazonia region of Brazil. The work incorporates the latest resource data and is based on the use of the Hybrid2 simulation code developed by the University of Massachusetts and NREL. Details of the baseline operating hybrid systems are reviewed, and the results of the latest detailed hybrid system evaluation for each site are summarized. Based on the system modeling results, separate recommendations for system modification and improvements are made.

  20. A new hybrid optimization algorithm CRO-DE for optimal coordination of overcurrent relays in complex power systems

    Directory of Open Access Journals (Sweden)

    Mohamed Zellagui

    2017-09-01

    Full Text Available The paper presents a new hybrid global optimization algorithm based on Chemical Reaction based Optimization (CRO and Di¤erential evolution (DE algorithm for nonlinear constrained optimization problems. This approach proposed for the optimal coordination and setting relays of directional overcurrent relays in complex power systems. In protection coordination problem, the objective function to be minimized is the sum of the operating time of all main relays. The optimization problem is subject to a number of constraints which are mainly focused on the operation of the backup relay, which should operate if a primary relay fails to respond to the fault near to it, Time Dial Setting (TDS, Plug Setting (PS and the minimum operating time of a relay. The hybrid global proposed optimization algorithm aims to minimize the total operating time of each protection relay. Two systems are used as case study to check the effeciency of the optimization algorithm which are IEEE 4-bus and IEEE 6-bus models. Results are obtained and presented for CRO and DE and hybrid CRO-DE algorithms. The obtained results for the studied cases are compared with those results obtained when using other optimization algorithms which are Teaching Learning-Based Optimization (TLBO, Chaotic Differential Evolution Algorithm (CDEA and Modiffied Differential Evolution Algorithm (MDEA, and Hybrid optimization algorithms (PSO-DE, IA-PSO, and BFOA-PSO. From analysing the obtained results, it has been concluded that hybrid CRO-DO algorithm provides the most optimum solution with the best convergence rate.

  1. Research on the filtering characteristic of single phase series hybrid active power filter based on fundamental magnetic flux compensation

    Science.gov (United States)

    Tian, Jun; Chen, Qiaofu; Zhang, Yuqi

    2012-12-01

    In this article, the PWM inverter works as a controlled fundamental current source in the single phase series hybrid active power filter (APF) based on fundamental magnetic flux compensation (FMFC). The series transformer can exhibit the self-impedance of primary winding to harmonic current, which forces harmonic current to flow into passive power filter. With the influence of harmonic current, the voltage of primary winding of transformer is a harmonic voltage, which makes the inverter output currents have a certain harmonic component, and it degrades the filtering characteristics. On the basis of PWM inverter, the mathematical model of series hybrid APF is established, and the filtering characteristics of single phase APF are analysed in detail. Three methods are gained to improve filtering characteristics: reasonably designing the inverter output filter inductance, increasing series transformer ratio and adopting voltage feed-forward control. Experimental results show that the proposed APF has greater validity.

  2. Simulation and performance evaluation of shunt hybrid power filter using fuzzy logic based non-linear control for power quality improvement

    Indian Academy of Sciences (India)

    R BALASUBRAMANIAN; R SANKARAN; S PALANI

    2017-09-01

    This paper deals with design and simulation of a three-phase shunt hybrid power filter consisting of a pair of 5th and 7th selective harmonic elimination passive power filters connected in series with a conventional active power filter with reduced kVA rating. The objective is to enhance the power quality in a distributionnetwork feeding variety of non-linear, time-varying and unbalanced loads. The theory and modelling of the entire power circuit in terms of synchronously rotating reference frame and leading to a non-linear control scheme is presented. This work involves introduction of individual fuzzy logic controllers for d and q axiscurrent control and for voltage regulation of the DC link capacitor. The simulation schematic covering the power and control circuits have been developed taking into account severe harmonic distortion caused by non-linear and unbalanced loads. The effectiveness of the fuzzy logic controller for the compensation of harmonics and reactive power has been verified by successive simulation runs and analysis of the results. The proposed controller is also able to compensate the distortion generated by the voltage- and current-fed non-linear loads, unbalanced and dynamically varying loads. Further, excellent regulation of the DC link voltage is accomplished, which significantly contributes to improvement of power quality.

  3. Photovoltaic Energy Conversion System Constructed by High Step-Up Converter with Hybrid Maximum Power Point Tracking

    OpenAIRE

    Hwu, K. I.; Tu, W. C.; Wang, C.R.

    2013-01-01

    A photovoltaic energy conversion system, constructed by high step-up converter with hybrid maximum power point tracking (HMPPT), is presented. A voltage converter with a high voltage conversion ratio is proposed, which is simple in circuit and easy in control. After this, such a converter operating with a suitable initial duty cycle of the pulsewidth-modulated (PWM) control signal, together with the proposed HMPPT algorithm combining the fractional open-circuit voltage method and the incremen...

  4. OPTIMAL PARAMETERS FOR ELECTRIC-POWER INSTALLATION COMPONENTS OF HYBRID CAR

    OpenAIRE

    2006-01-01

    A conception for low-cost reconstruction of cars using hybrid drive was developed. Integrations of internal-combustion engine with electric motor fed from lead-acid storage battery and supercapacitor is the aim of the reconstruction. Such a way for modernization allows fast provide the output of hybrid cars in Ukraine in the framework of the program of energy storage technologies.

  5. Development of an Auxiliary Power Unit Specification for Medium Duty Series Hybrid Electric Vehicles

    Science.gov (United States)

    1998-06-01

    As a part of the Defense Advanced Research Projects Agency (DARPA) program to develop hybrid and electric vehicles , a specification for medium duty...hybrid electric vehicles . Intended applications include medium duty commercial vehicles and buses. For the purposes of this specification an APU is

  6. Design of Solar/Electric Powered Hybrid Vehicle (SEPHV System with Charge Pattern Optimization for Energy Cost

    Directory of Open Access Journals (Sweden)

    T.Balamurugan

    2014-01-01

    Full Text Available This paper proposes a Solar Electric Powered Hybrid Vehicle (SEPHV system which solves the major problems of fuel and pollution. An electric vehicle usually uses a battery which has been charged by external electrical power supply. All recent electric vehicles present a drive on AC power supplied motor. An inverter set is required to be connected with the battery through which AC power is converted to DC power. During this conversion many losses take place and also the maintenance cost of the AC System is very high. The proposed topology has the most feasible solar/electric power generation system mounted on the vehicle to charge the battery during all durations. With a view of providing ignited us to develop this “Solar/Electric Powered Hybrid Vehicle” [SEPHV].This multi charging vehicle can charge itself from both solar and electric power. The vehicle is altered out of a Maruti Omni vehicle by replacing its engine with a 1.2HP, 24V Permanent Magnet DC [PMDC] Motor. The Supply to the motor is obtained from a battery set of 12V, 150AH. The household electric supply of 230V is reduced with a step-down transformer to 48V and then it is converted to the DC with a rectifying unit to charge the battery. Two solar panels each with a rating of 230watts are attached to the top of the Vehicle to grab the solar energy and is controlled with a help of charge controller. The SEPHV can be driven by 1.2 HP PMDC motor consisting of two 230 watts PV panel in the voltage rating of 24 V. The power which is absorbed by the PV panel is stored into the four 150 AH 12 V batteries. When there is no presence of sun, electric power supply act as an auxiliary energy source. For controlling speed of the motor, a switch is designed with four tapping, provided with different values of resistance at each tapping. It acts as a speed control switch for Solar/Electric Powered Hybrid Vehicle. This type of technique is to reduce the running cost and increasing the running

  7. The Influence of Diesel Fuel Subsidies and Taxes on the Potential for Solar-Powered Hybrid Systems in Africa

    Directory of Open Access Journals (Sweden)

    Paul Bertheau

    2015-08-01

    Full Text Available Many people in African countries lack access to sufficient electricity supply due to missing infrastructure of the centralized conventional power generation system. In order to provide electricity to a wider part of the population, it is necessary to exploit the vast renewable resources in African countries. Therefore, this paper scrutinizes the economic advantages of photovoltaic-based hybrid systems over fossil fuel-based power generation. A simulation model is applied in order to calculate the cost advantage of hybrid systems compared to diesel-only systems for the entire continent on a long term basis by applying two scenarios: one based on world market diesel prices and the other one based on national diesel prices. The results indicate that average power generation costs per country can be reduced by up to 0.11 €/kWh considering world market diesel prices and by up to 0.48 €/kWh considering national diesel prices. Furthermore, the effect of diesel fuel subsidies and taxes on the renewable energy potential and the respective savings are examined. These findings may ameliorate the policy development according to fossil fuel subsidies and taxes and demonstrate the advantages of decentralized renewable hybrid systems especially in rural areas of Africa.

  8. A New Hybrid Model Based on Data Preprocessing and an Intelligent Optimization Algorithm for Electrical Power System Forecasting

    Directory of Open Access Journals (Sweden)

    Ping Jiang

    2015-01-01

    Full Text Available The establishment of electrical power system cannot only benefit the reasonable distribution and management in energy resources, but also satisfy the increasing demand for electricity. The electrical power system construction is often a pivotal part in the national and regional economic development plan. This paper constructs a hybrid model, known as the E-MFA-BP model, that can forecast indices in the electrical power system, including wind speed, electrical load, and electricity price. Firstly, the ensemble empirical mode decomposition can be applied to eliminate the noise of original time series data. After data preprocessing, the back propagation neural network model is applied to carry out the forecasting. Owing to the instability of its structure, the modified firefly algorithm is employed to optimize the weight and threshold values of back propagation to obtain a hybrid model with higher forecasting quality. Three experiments are carried out to verify the effectiveness of the model. Through comparison with other traditional well-known forecasting models, and models optimized by other optimization algorithms, the experimental results demonstrate that the hybrid model has the best forecasting performance.

  9. Harnessing the hybrid power supply systems of utility grid and photovoltaic panels at retrofit residential single family building in Medan

    Science.gov (United States)

    Pangaribuan, A. B.; Rahmat, R. F.; Lidya, M. S.; Zálešák, M.

    2017-01-01

    The paper describes improvisation mode of energy supply source by collaboration between national utility grid as represented by fossil fuels and PV as independent renewable power resource in order to aim the energy consumptions efficiently in retrofit single family house. In this case, one existing single family house model in Medan, Indonesia was observed for the possibility of future refurbishment. The eco-design version of the house model and prediction analyses regarding nearby potential renewable energy resource (solar system) had been made using Autodesk Revit MEP 2015, Climate Consultant 6.0 and Green Building Studio Analysis. Economical evaluation of using hybrid power supply is discussed as well.

  10. Relativistic Fermi-Ulam map: Application to WEGA stellarator lower hybrid power operation

    Energy Technology Data Exchange (ETDEWEB)

    Fuchs, V.; Seidl, J.; Krlín, L.; Pánek, R.; Preinhaelter, J.; Urban, J. [Institute of Plasma Physics AS CR, v.v.i., Prague (Czech Republic); Laqua, H. P. [Max-Planck-Institute for Plasma Physics, Wendelsteinstr. 1, 17491 Greifswald (Germany)

    2014-06-15

    Analytical and numerical support is here provided in support of the explanation [Laqua et al., Plasma Phys. Controlled Fusion 56, 075022 (2014)] for the observation of ∼MeV electrons during Lower Hybrid (LH) operation in EC pre-heated plasma at the WEGA stellarator [Otte et al., Nukleonika, 57, 171 (2012)]. In the quoted experiments, LH power from the WEGA TE{sub 11} circular waveguide, 9 cm diameter, un-phased, 2.45 GHz antenna, is radiated into a B ≅ 0.5 T, n{sup ¯}{sub e} ≅ 5 × 10{sup 17} 1/m{sup 3} plasma at T{sub e} ≅ 10 eV bulk temperature with an EC-generated 50 keV population of electrons. In response, the fast electrons travel around flux or drift surfaces essentially without collisions, repeatedly interacting with the rf field close to the antenna mouth, and gaining energy in the process. Our WEGA antenna calculations indicate a predominantly standing electric field pattern at the antenna mouth. From a simple approximation of the corresponding Hamiltonian equations of motion, we derive here a relativistic generalization of the simplified area-preserving Fermi-Ulam (F-U) map [M. A. Lieberman and A. J. Lichtenberg, Phys. Rev. A 5, 1852 (1972), Lichtenberg et al., Physica D 1, 291 (1980)], allowing phase-space global stochasticity analysis. At typical WEGA plasma and antenna conditions, and with correlated phases between electron–antenna electric field interaction events, the F-U map and supporting numerical simulations predict an absolute energy barrier in the range of 300 keV. In contrast, with random phases intervening between interaction events, the electron energy can reach ∼MeV values, compatible with the measurements on WEGA [Laqua et al., Plasma Phys. Controlled Fusion 56, 075022 (2014)].

  11. Development of a 16 kHz repetition rate, 110 W average power copper HyBrID laser

    Indian Academy of Sciences (India)

    R Biswal; P K Agrawal; G K Mishra; S V Nakhe; S K Dixit; J K Mittal

    2010-11-01

    This paper presents the design and performance analysis of an indigenously developed 110 W average output power copper HyBrID laser operating at 16 kHz pulse repetition rate. The laser active medium was confined within a fused silica tube of ∼ 6 cm diameter and ∼ 200 cm active length. An in-house developed high-power (∼ 10 kW) solid-state pulser was used as the electrical excitation source. A simple estimation of deposited electrical power, at the laser head, was carried out and based on it, the laser tube efficiency was found to be 2.9% at 70 W and 2.2% at 110 W laser power levels.

  12. Energy management of a power-split plug-in hybrid electric vehicle based on genetic algorithm and quadratic programming

    Science.gov (United States)

    Chen, Zheng; Mi, Chris Chunting; Xiong, Rui; Xu, Jun; You, Chenwen

    2014-02-01

    This paper introduces an online and intelligent energy management controller to improve the fuel economy of a power-split plug-in hybrid electric vehicle (PHEV). Based on analytic analysis between fuel-rate and battery current at different driveline power and vehicle speed, quadratic equations are applied to simulate the relationship between battery current and vehicle fuel-rate. The power threshold at which engine is turned on is optimized by genetic algorithm (GA) based on vehicle fuel-rate, battery state of charge (SOC) and driveline power demand. The optimal battery current when the engine is on is calculated using quadratic programming (QP) method. The proposed algorithm can control the battery current effectively, which makes the engine work more efficiently and thus reduce the fuel-consumption. Moreover, the controller is still applicable when the battery is unhealthy. Numerical simulations validated the feasibility of the proposed controller.

  13. The Design of Drive Circuit with High-power Output for Two-phase Hybrid Stepping Motor Based on BY-5064

    Institute of Scientific and Technical Information of China (English)

    MA Xiao-jiao; LI Cheng-gui; CAI Zheng; ZHAO Li-guo

    2011-01-01

    A kind of drive circuit which high-power output for stepping motor, based two-phase hybrid stepping motor are designed, achieved. is low power consumption, high-performance and on BY-5064, and a kind of dedicated circuit for drive control for stepping motor with high-power is

  14. Hybrid vehicles

    Energy Technology Data Exchange (ETDEWEB)

    West, J.G.W. [Electrical Machines (United Kingdom)

    1997-07-01

    The reasons for adopting hybrid vehicles result mainly from the lack of adequate range from electric vehicles at an acceptable cost. Hybrids can offer significant improvements in emissions and fuel economy. Series and parallel hybrids are compared. A combination of series and parallel operation would be the ideal. This can be obtained using a planetary gearbox as a power split device allowing a small generator to transfer power to the propulsion motor giving the effect of a CVT. It allows the engine to run at semi-constant speed giving better fuel economy and reduced emissions. Hybrid car developments are described that show the wide range of possible hybrid systems. (author)

  15. Multi-objective Optimization of Hybrid Energy Storage and Assessment Indices in Microgrid%微电网复合储能多目标优化配置方法及评价指标

    Institute of Scientific and Technical Information of China (English)

    谭兴国; 王辉; 张黎; 邹亮

    2014-01-01

    复合储能在微电网功率平衡、平滑可再生能源波动、提升电能质量等方面发挥多重作用,针对包含光伏发电、风力发电和典型负荷的微电网,提出一种合理配置复合储能容量的方法。针对复合储能优化配置,以装置成本最低、功率匹配最佳、可再生能源输出功率平滑度最好建立复合储能多目标优化数学模型,采用自适应惯性权重的粒子群算法求解复合储能多目标函数最优解;针对子目标函数权重系数的确定,提出目标函数适应度离差排序法;提出了定量评估微电网储能多目标优化效果的参数指标,并以此为依据,对比了微电网内蓄电池单一储能多目标优化与复合储能多目标优化结果。最后,通过MATLAB编程进行实例验算,验证了方法的合理、有效性。%Hybrid energy storage technology has multiple effects on the microgrid,which include keeping power balanced, smoothing fluctuating power of renewable energy and improving power quality,etc.Based on a typical microgrid with photovoltaic/wind/storage and normal loads,a rational capacity allocation method for the hybrid energy storage system is put forward.A hybrid energy storage configuration multi-obj ective optimization mathematical model is developed at minimum cost, optimal match between power generation and load demand and best smoothing effects of renewable generation.An adaptive weight particle swarm optimization algorithm is put forward to get the optimal solution.To determine the weights of each obj ective function in the multi-obj ective optimization model,a ranking method based on average fitness deviation of each obj ective function is presented.To evaluate the impact of energy storage application on microgrid,assessment indices of energy storage multi-obj ective optimization are provided;based on which,single battery and composite energy storagemulti-obj ective compensation effects are compared with

  16. Fernando de Noronha island, Brazil: project of hybrid diesel and wind power system; Ilha de Fernando de Noronha, Brasil: projeto do sistema hibrido eolico-diesel

    Energy Technology Data Exchange (ETDEWEB)

    Feitosa, Everaldo A.N.; Pereira, Alexandre L.; Rohatgi, Janardan S.; Barros, Maria E.M. de [Pernambuco Univ., Recife, PE (Brazil). Dept. de Engenharia Mecanica. Grupo de Energia Eolica

    1996-12-31

    This paper describes the first hybrid system (wind power/diesel) in Brazil, located at Fernando de Noronha island. The electric generation system of the hybrid system is discussed. It is also presented the main project aspects as well as the simulations performed by the Federal University of Pernambuco (group of wind power researches) 7 refs., 6 figs., 1 tab.; e-mail: EOLICA at npd.ufpe.br

  17. High-performance cryogenic fractal 180° hybrid power divider with integrated directional coupler

    Science.gov (United States)

    Ladu, Adelaide; Montisci, Giorgio; Valente, Giuseppe; Navarrini, Alessandro; Marongiu, Pasqualino; Pisanu, Tonino; Mazzarella, Giuseppe

    2017-06-01

    A 180° hybrid and a directional coupler to be employed in the P-band cryogenic receiver of the Sardinia Radio Telescope are proposed in this work. An in-depth study of the issues related to the use of microwave components for cryogenic radio astronomy receivers is carried out to select the best suited technology and configuration. As a result, a planar fractal 180° hybrid configuration available in the literature has been optimized aiming to increase the operating bandwidth in order to comply with the design specifications of the application at hand. A coupled line directional coupler with weak coupling and high isolation, used to calibrate the receiver chain, is cascaded to the 180° hybrid and realized in the same layout. The final device, consisting of the 180° hybrid and the directional coupler, has been manufactured and tested at the cryogenic temperature of 20 K, showing a good agreement between experimental results and predicted performance.

  18. Energy and Propulsion Optimization of Solid-Propellant Grain of a Hybrid Power Device

    OpenAIRE

    Bondarchuk Sergey S.; Bondarchuk Iliya S.; Borisov Boris V.; Zhukov Alexandr S.

    2016-01-01

    A method of distribution of an additional solid-phase component (oxidizer) providing uniformity of grain burning for the purpose of evaluation and optimization of energy and propulsion parameters of hybrid solid-propellant motor is proposed in the paper.

  19. Energy and Propulsion Optimization of Solid-Propellant Grain of a Hybrid Power Device

    Science.gov (United States)

    Bondarchuk, Sergey S.; Bondarchuk, Iliya S.; Borisov, Boris V.; Zhukov, Alexandr S.

    2016-02-01

    A method of distribution of an additional solid-phase component (oxidizer) providing uniformity of grain burning for the purpose of evaluation and optimization of energy and propulsion parameters of hybrid solid-propellant motor is proposed in the paper.

  20. Modular Power System Configured with Standard Product Hybrid DC-DC Converters Project

    Data.gov (United States)

    National Aeronautics and Space Administration — VPT proposes an innovative concept whereby complex, multiple-output, DC-DC converter systems can be configured through use of only 2 standard product hybrid DC-DC...