WorldWideScience

Sample records for hybrid micro lens

  1. Hybrid cycles for micro generation

    International Nuclear Information System (INIS)

    Campanari, S.

    2000-01-01

    This paper deals with the main features of two emerging technologies in the field of small-scale power generation, micro turbines and Solid Oxide Fuel Cells, discussing the extremely high potential of their combination into hybrid cycles and their possible role for distributed cogeneration [it

  2. Athermal design and analysis of glass-plastic hybrid lens

    Science.gov (United States)

    Yang, Jian; Cen, Zhaofeng; Li, Xiaotong

    2018-01-01

    With the rapid development of security market, the glass-plastic hybrid lens has gradually become a choice for the special requirements like high imaging quality in a wide temperature range and low cost. The reduction of spherical aberration is achieved by using aspherical surface instead of increasing the number of lenses. Obviously, plastic aspherical lens plays a great role in the cost reduction. However, the hybrid lens has a priority issue, which is the large thermal coefficient of expansion of plastic, causing focus shift and seriously affecting the imaging quality, so the hybrid lens is highly sensitive to the change of temperature. To ensure the system operates normally in a wide temperature range, it is necessary to eliminate the influence of temperature on the hybrid lens system. A practical design method named the Athermal Material Map is summarized and verified by an athermal design example according to the design index. It includes the distribution of optical power and selection of glass or plastic. The design result shows that the optical system has excellent imaging quality at a wide temperature range from -20 ° to 70 °. The method of athermal design in this paper has generality which could apply to optical system with plastic aspherical surface.

  3. Millimeter positron focusing using a hybrid lens design

    International Nuclear Information System (INIS)

    Cheung, C.K.; Kwan, P.Y.; Shan, Y.Y.; Naik, P.S.; Weng, H.M.; Beling, C.D.; Fung, S.

    2004-01-01

    The study of metal-semiconductor and metal-oxide-semiconductor systems with low energy positrons is made considerably easier if structures of millimeter dimension can be studied. For this reason the production of a positron beam of sub-millimeter dimension has been a long-term goal of the positron research group at the university of Hong Kong. The hybrid lens system employed consists of a standard Soa extraction lens in a magnetic field free region followed by a gridded Einzel lens that focuses positrons into a 100G magnetic funnel at an energy of 10keV for transportation to the target. Here we report on the present progress, by showing the capability of obtaining millimeter diameter focusing at a preliminary 7.5 kV beam energy. (orig.)

  4. Fabrication of a Micro-Lens Array Mold by Micro Ball End-Milling and Its Hot Embossing

    Directory of Open Access Journals (Sweden)

    Peng Gao

    2018-02-01

    Full Text Available Hot embossing is an efficient technique for manufacturing high-quality micro-lens arrays. The machining quality is significant for hot embossing the micro-lens array mold. This study investigates the effects of micro ball end-milling on the machining quality of AISI H13 tool steel used in the micro-lens array mold. The micro ball end-milling experiments were performed under different machining strategies, and the surface roughness and scallop height of the machined micro-lens array mold are measured. The experimental results showed that a three-dimensional (3D offset spiral strategy could achieve a higher machining quality in comparison with other strategies assessed in this study. Moreover, the 3D offset spiral strategy is more appropriate for machining the micro-lens array mold. With an increase of the cutting speed and feed rate, the surface roughness of the micro-lens array mold slightly increases, while a small step-over can greatly reduce the surface roughness. In addition, a hot embossing experiment was undertaken, and the obtained results indicated higher-quality production of the micro-lens array mold by the 3D offset spiral strategy.

  5. Manufacturing PDMS micro lens array using spin coating under a multiphase system

    International Nuclear Information System (INIS)

    Sun, Rongrong; Yang, Hanry; Rock, D Mitchell; Danaei, Roozbeh; Panat, Rahul; Kessler, Michael R; Li, Lei

    2017-01-01

    The development of micro lens arrays has garnered much interest due to increased demand of miniaturized systems. Traditional methods for manufacturing micro lens arrays have several shortcomings. For example, they require expensive facilities and long lead time, and traditional lens materials (i.e. glass) are typically heavy, costly and difficult to manufacture. In this paper, we explore a method for manufacturing a polydimethylsiloxane (PDMS) micro lens array using a simple spin coating technique. The micro lens array, formed under an interfacial tension dominated system, and the influence of material properties and process parameters on the fabricated lens shape are examined. The lenses fabricated using this method show comparable optical properties—including surface finish and image quality—with a reduced cost and manufacturing lead time. (paper)

  6. A new concept of a hybrid trapped field magnet lens

    Science.gov (United States)

    Takahashi, Keita; Fujishiro, Hiroyuki; Ainslie, Mark D.

    2018-04-01

    In this paper, a new concept of a hybrid trapped field magnet lens (HTFML) is proposed. The HTMFL exploits the ‘vortex pinning effect’ of an outer superconducting bulk cylinder, which is magnetized as a trapped field magnet (TFM) using field-cooled magnetization (FCM), and the ‘diamagnetic shielding effect’ of an inner bulk magnetic lens to generate a concentrated magnetic field higher than the trapped field from the TFM in the bore of the magnetic lens. This requires that, during the zero-field-cooled magnetization process, the outer cylinder is in the normal state (T> superconducting transition temperature, T c) and the inner lens is in the superconducting state (T operating temperature, then removing the external field. This is explored for two potential cases: (1) exploiting the difference in T c of two different bulk materials (‘case-1’), e.g. MgB2 (T c = 39 K) and GdBaCuO (T c = 92 K) or (2) using the same material for the whole HTFML, e.g., GdBaCuO, but utilizing individually controlled cryostats, the same cryostat with different cooling loops or coolants, or heaters that keep the outer bulk cylinder at a temperature above T c to achieve the same desired effect. The HTFML is verified using numerical simulations for ‘case-1’ using an MgB2 cylinder and GdBaCuO lens pair and for ‘case-2’ using a GdBaCuO cylinder and GdBaCuO lens pair. As a result, the HTFML could reliably generate a concentrated magnetic field B c = 4.73 T with the external magnetizing field B app = 3 T in the ‘case-1’, and a higher B c = 13.49 T with higher B app = 10 T in the ‘case-2’, respectively. This could, for example, be used to enhance the magnetic field in the bore of a bulk superconducting NMR/MRI system to improve its resolution.

  7. Micro-ball lens structure fabrication based on drop on demand printing the liquid mold

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Xiaoyang, E-mail: zhuxy1026@163.com; Zhu, Li, E-mail: zhuli@njust.edu.cn; Chen, Hejuan; Yang, Lijun; Zhang, Weiyi

    2016-01-15

    Graphical abstract: - Highlights: • The glycerol micro-ball droplet was introduced to be as liquid mold to fabricate micro-ball lens. • A molding process was used to fabricate the micro-ball lens and the scales of them can be controlled. • The accurate molding process is mainly attributed to the ultrahigh adhesion of the treated substrate. • The micro-ball lenses with contact angle of 120° and 150° were fabricated, analyzed and discussed. - Abstract: In this paper, we demonstrated a simple micro-ball lens array (MBLA) fabrication method using a drop-on-demand (DOD) droplet printing technique and liquid mold. The micro-ball droplet array on the hydrophobic surface is used as the liquid mold to fabricate the MBLA. The ultrahigh adhesion force between the micro-ball droplet and the substrate is ascribed to the Wenzel state of the micro-ball droplet, while the replication process with low position error is attributed to the ultrahigh adhesion force between the micro-ball droplet and the substrate and the high viscosity of the micro-ball droplet and polydimethylsiloxane (PDMS) liquid. The micro-ball lenses (MBLs) with a contact angle of 120° and 150° were fabricated and the important fabrication details were discussed. The optical performance and scanning electron microscope (SEM) data of the MBLs showed that the MBLs had high quality surface morphology and good optical performance.

  8. Development of 3d micro-nano hybrid patterns using anodized aluminum and micro-indentation

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Hong Gue; Kwon, Jong Tae [Division of Mechanical Engineering and Mechatronics, Kangwon National University, 1 Kangwondaehakgil, Chunchon, Gangwon-do, 200-701 (Korea, Republic of); Seo, Young Ho [Division of Mechanical Engineering and Mechatronics, Kangwon National University, 1 Kangwondaehakgil, Chunchon, Gangwon-do, 200-701 (Korea, Republic of)], E-mail: mems@kangwon.ac.kr; Kim, Byeong Hee [Division of Mechanical Engineering and Mechatronics, Kangwon National University, 1 Kangwondaehakgil, Chunchon, Gangwon-do, 200-701 (Korea, Republic of)

    2008-07-31

    We developed a simple and cost-effective method of fabricating 3D micro-nano hybrid patterns in which micro-indentation is applied on the anodized aluminum substrate. Nano-patterns were formed first on the aluminum substrate, and then micro-patterns were fabricated by deforming the nano-patterned aluminum substrate. Hemispherical nano-patterns with a 150 nm-diameter on an aluminum substrate were fabricated by anodizing and alumina removing process. Then, micro-pyramid patterns with a side-length of 50 {mu}m were formed on the nano-patterns using micro-indentation. To verify 3D micro-nano hybrid patterns, we replicated 3D micro-nano hybrid patterns by a hot-embossing process. 3D micro-nano hybrid patterns may be used in nano-photonic devices and nano-biochips applications.

  9. Development of 3d micro-nano hybrid patterns using anodized aluminum and micro-indentation

    International Nuclear Information System (INIS)

    Shin, Hong Gue; Kwon, Jong Tae; Seo, Young Ho; Kim, Byeong Hee

    2008-01-01

    We developed a simple and cost-effective method of fabricating 3D micro-nano hybrid patterns in which micro-indentation is applied on the anodized aluminum substrate. Nano-patterns were formed first on the aluminum substrate, and then micro-patterns were fabricated by deforming the nano-patterned aluminum substrate. Hemispherical nano-patterns with a 150 nm-diameter on an aluminum substrate were fabricated by anodizing and alumina removing process. Then, micro-pyramid patterns with a side-length of 50 μm were formed on the nano-patterns using micro-indentation. To verify 3D micro-nano hybrid patterns, we replicated 3D micro-nano hybrid patterns by a hot-embossing process. 3D micro-nano hybrid patterns may be used in nano-photonic devices and nano-biochips applications

  10. A PDMS-based cylindrical hybrid lens for enhanced fluorescence detection in microfluidic systems.

    Science.gov (United States)

    Lin, Bor-Shyh; Yang, Yu-Ching; Ho, Chong-Yi; Yang, Han-Yu; Wang, Hsiang-Yu

    2014-02-13

    Microfluidic systems based on fluorescence detection have been developed and applied for many biological and chemical applications. Because of the tiny amount of sample in the system; the induced fluorescence can be weak. Therefore, most microfluidic systems deploy multiple optical components or sophisticated equipment to enhance the efficiency of fluorescence detection. However, these strategies encounter common issues of complex manufacturing processes and high costs. In this study; a miniature, cylindrical and hybrid lens made of polydimethylsiloxane (PDMS) to improve the fluorescence detection in microfluidic systems is proposed. The hybrid lens integrates a laser focusing lens and a fluorescence collecting lens to achieve dual functions and simplify optical setup. Moreover, PDMS has advantages of low-cost and straightforward fabrication compared with conventional optical components. The performance of the proposed lens is first examined with two fluorescent dyes and the results show that the lens provides satisfactory enhancement for fluorescence detection of Rhodamine 6G and Nile Red. The overall increments in collected fluorescence signal and detection sensitivity are more than 220% of those without lens, and the detection limits of Rhodamine 6G and Nile red are lowered to 0.01 μg/mL and 0.05 μg/mL, respectively. The hybrid lens is further applied to the detection of Nile red-labeled Chlorella vulgaris cells and it increases both signal intensity and detection sensitivity by more than 520%. The proposed hybrid lens also dramatically reduces the variation in detected signal caused by the deviation in incident angle of excitation light.

  11. Fabrication of polymer micro-lens array with pneumatically diaphragm-driven drop-on-demand inkjet technology.

    Science.gov (United States)

    Xie, Dan; Zhang, Honghai; Shu, Xiayun; Xiao, Junfeng

    2012-07-02

    The paper reports an effective method to fabricate micro-lens arrays with the ultraviolet-curable polymer, using an original pneumatically diaphragm-driven drop-on-demand inkjet system. An array of plano convex micro-lenses can be formed on the glass substrate due to surface tension and hydrophobic effect. The micro-lens arrays have uniform focusing function, smooth and real planar surface. The fabrication process showed good repeatability as well, fifty micro-lenses randomly selected form 9 × 9 miro-lens array with an average diameter of 333.28μm showed 1.1% variations. Also, the focal length, the surface roughness and optical property of the fabricated micro-lenses are measured, analyzed and proved satisfactory. The technique shows great potential for fabricating polymer micro-lens arrays with high flexibility, simple technological process and low production cost.

  12. Micro tooling technologies for polymer micro replication: direct, indirect and hybrid process chains

    DEFF Research Database (Denmark)

    Tosello, Guido; Hansen, Hans Nørgaard

    2009-01-01

    The increasing employment of micro products, of products containing micro parts and of products with micro-structured surfaces calls for mass fabrication technologies based on replication processes. In many cases, a suitable solution is given by the use of polymer micro products, whose production...... and performance of the corresponding micro mould. Traditional methods of micro tooling, such as various machining processes (e.g. micro milling, micro electrical discharge machining) have already reached their limitations with decreasing dimensions of mould inserts and cavities. To this respect, tooling process...... chains based on combination of micro manufacturing processes (defined as hybrid tooling) have been established in order to obtain further features miniaturization and increased accuracy. In this paper, examples and performance of different hybrid tooling approaches as well as challenges, opportunities...

  13. Direct fabrication of polymer micro-lens array

    Science.gov (United States)

    Coppola, S.; Pagliarulo, V.; Vespini, V.; Nasti, G.; Olivieri, F.; Grilli, S.; Ferraro, P.

    2017-06-01

    In order to break the rigidity of classic lithographic techniques, a flexible pyro-electric-electrohydrodynamic (EHD) inkjet printing is presented. In particular, here is showed a method able to manipulate highly viscous polymers, usable for optical integrated devices. The system proposed reaches spatial resolution up to the nano-scale and can print, for instance, nano-particles and high viscous polymer solutions. This technique allows writing patterns directly onto a substrate of interest in 2D or in 3D configuration and is studied in order to overcome limitations in terms of type of materials, geometry and thickness of the substrate. In the present work, we show the potential of pyro-EHD printing in fields as optics and micro-fluidics. A micro-channel chip is functionalized with a PDMS-made micro-lenses array, directly printed on the chip. The geometric properties and the quality of the lenses are evaluated by a Digital Holography (DH) analysis.

  14. Automated Micro-Object Detection for Mobile Diagnostics Using Lens-Free Imaging Technology

    Directory of Open Access Journals (Sweden)

    Mohendra Roy

    2016-05-01

    Full Text Available Lens-free imaging technology has been extensively used recently for microparticle and biological cell analysis because of its high throughput, low cost, and simple and compact arrangement. However, this technology still lacks a dedicated and automated detection system. In this paper, we describe a custom-developed automated micro-object detection method for a lens-free imaging system. In our previous work (Roy et al., we developed a lens-free imaging system using low-cost components. This system was used to generate and capture the diffraction patterns of micro-objects and a global threshold was used to locate the diffraction patterns. In this work we used the same setup to develop an improved automated detection and analysis algorithm based on adaptive threshold and clustering of signals. For this purpose images from the lens-free system were then used to understand the features and characteristics of the diffraction patterns of several types of samples. On the basis of this information, we custom-developed an automated algorithm for the lens-free imaging system. Next, all the lens-free images were processed using this custom-developed automated algorithm. The performance of this approach was evaluated by comparing the counting results with standard optical microscope results. We evaluated the counting results for polystyrene microbeads, red blood cells, and HepG2, HeLa, and MCF7 cells. The comparison shows good agreement between the systems, with a correlation coefficient of 0.91 and linearity slope of 0.877. We also evaluated the automated size profiles of the microparticle samples. This Wi-Fi-enabled lens-free imaging system, along with the dedicated software, possesses great potential for telemedicine applications in resource-limited settings.

  15. Micro sized implantable ball lens-based fiber optic probe design

    Science.gov (United States)

    Cha, Jaepyeong; Kang, Jin U.

    2014-02-01

    A micro sized implantable ball lens-based fiber optic probe design is described for continuous monitoring of brain activity in freely behaving mice. A prototype uses a 500-micron ball lens and a highly flexible 350-micron-diameter fiber bundle, which are enclosed by a 21G stainless steel sheath. Several types and thickness of brain tissue, consisting of fluorescent probes such as GFP, GCaMP3 calcium indicator, are used to evaluate the performance of the imaging probe. Measured working distance is approximately 400-μm, but is long enough to detect neural activities from cortical and cerebellar tissues of mice brain.

  16. Hybrid micromachining using a nanosecond pulsed laser and micro EDM

    International Nuclear Information System (INIS)

    Kim, Sanha; Chung, Do Kwan; Shin, Hong Shik; Chu, Chong Nam; Kim, Bo Hyun

    2010-01-01

    Micro electrical discharge machining (micro EDM) is a well-known precise machining process that achieves micro structures of excellent quality for any conductive material. However, the slow machining speed and high tool wear are main drawbacks of this process. Though the use of deionized water instead of kerosene as a dielectric fluid can reduce the tool wear and increase the machine speed, the material removal rate (MRR) is still low. In contrast, laser ablation using a nanosecond pulsed laser is a fast and non-wear machining process but achieves micro figures of rather low quality. Therefore, the integration of these two processes can overcome the respective disadvantages. This paper reports a hybrid process of a nanosecond pulsed laser and micro EDM for micromachining. A novel hybrid micromachining system that combines the two discrete machining processes is introduced. Then, the feasibility and characteristics of the hybrid machining process are investigated compared to conventional EDM and laser ablation. It is verified experimentally that the machining time can be effectively reduced in both EDM drilling and milling by rapid laser pre-machining prior to micro EDM. Finally, some examples of complicated 3D micro structures fabricated by the hybrid process are shown

  17. Stop grating for perfect replication of micro Fresnel lens by thermal imprinting

    International Nuclear Information System (INIS)

    Gao, Yulong; Lin, Jie; Jin, Peng; Tan, Jiubin; Davies, Graham; Prewett, Philip D

    2012-01-01

    A stop grating concept is proposed to improve polymer filling in the thermal imprinting of a micro Fresnel lens structure. The stop grating consists of line and space structures outside the Fresnel lens pattern zone area. The experimental results have proved that the stop grating can help to achieve the complete filling of a mold, at the same time acting as a stop to prevent possible damage to the mold surface relief structures during imprinting press. A computer simulation was carried out to identify the phenomena of micro-holes at the edge of imprinted pattern. By removing the cavity between the pattern area and stop grating, perfect imprinting results have been achieved. (paper)

  18. Improvement of illumination uniformity for LED flat panel light by using micro-secondary lens array.

    Science.gov (United States)

    Lee, Hsiao-Wen; Lin, Bor-Shyh

    2012-11-05

    LED flat panel light is an innovative lighting product in recent years. However, current flat panel light products still contain some drawbacks, such as narrow lighting areas and hot spots. In this study, a micro-secondary lens array technique was proposed and applied for the design of the light guide surface to improve the illumination uniformity. By using the micro-secondary lens array, the candela distribution of the LED flat panel light can be adjusted to similar to batwing distribution to improve the illumination uniformity. The experimental results show that the enhancement of the floor illumination uniformity is about 61%, and that of the wall illumination uniformity is about 20.5%.

  19. First results of micro-neutron tomography by use of a focussing neutron lens

    CERN Document Server

    Masschaele, B; Cauwels, P; Dierick, M; Jolie, J; Mondelaers, W

    2001-01-01

    Since the appearance of high flux neutron beams, scientists experimented with neutron radiography. This high beam flux combined with modern neutron to visible light converters leads to the possibility of performing fast neutron micro-tomography. The first results of cold neutron tomography with a neutron lens are presented in this article. Samples are rotated in the beam and the projections are recorded with a neutron camera. The 3D reconstruction is performed with cone beam reconstruction software.

  20. Battery requirements and technologies for micro hybrid applications

    Energy Technology Data Exchange (ETDEWEB)

    Karden, Eckhard; Ploumen, Serve; Spijker, Engbert [Ford Forschungszentrum Aachen GmbH (Germany); Kok, Daniel [Ford Dunton Engineering Center, Basildon, Essex (United Kingdom)

    2010-07-01

    Micro hybrids are part of all European carmakers' CO{sub 2} roadmaps and will get high market share, becoming a standard fit for mainstream powertrains. Starting from vehicle level, the paper outlines system requirements and typical technical solutions. A case study demonstrates potential and limitations of regenerative braking in micro hybrid systems. The lead/acid battery dynamic charge acceptance (DCA) is a major limitation for efficient energy recuperation, and hence fuel and CO{sub 2} saving in micro hybrids. Strengths and weaknesses of the lead/acid battery are discussed with respect to both classical automotive as well as the new micro hybrid applications. The latter impose characteristic high demands on the starting - lighting - ignition (SLI) battery or the storage system that is going to replace it, namely extensive shallow cycling at partial state of charge (PSOC) and significantly improved DCA. Delivering these additional functions robustly and reliably at minimum on-cost for high-volume applications is the key challenge that the automotive lead/acid battery industry is currently confronted with. (orig.)

  1. Hybrid Micro-Electro-Mechanical Tunable Filter

    Science.gov (United States)

    2007-09-01

    and polymer hybrid actuator and applications as a tunable filter in telecom and in IR chemical detector,” in Micromachining and Microfabrication...consistently achieved. At this temperature, SU8 - SU-8 bonding withstood subsequent processing steps, resulting in a 57% bond yield and an overall 30

  2. Multiocular image sensor with on-chip beam-splitter and inner meta-micro-lens for single-main-lens stereo camera.

    Science.gov (United States)

    Koyama, Shinzo; Onozawa, Kazutoshi; Tanaka, Keisuke; Saito, Shigeru; Kourkouss, Sahim Mohamed; Kato, Yoshihisa

    2016-08-08

    We developed multiocular 1/3-inch 2.75-μm-pixel-size 2.1M- pixel image sensors by co-design of both on-chip beam-splitter and 100-nm-width 800-nm-depth patterned inner meta-micro-lens for single-main-lens stereo camera systems. A camera with the multiocular image sensor can capture horizontally one-dimensional light filed by both the on-chip beam-splitter horizontally dividing ray according to incident angle, and the inner meta-micro-lens collecting the divided ray into pixel with small optical loss. Cross-talks between adjacent light field images of a fabricated binocular image sensor and of a quad-ocular image sensor are as low as 6% and 7% respectively. With the selection of two images from one-dimensional light filed images, a selective baseline for stereo vision is realized to view close objects with single-main-lens. In addition, by adding multiple light field images with different ratios, baseline distance can be tuned within an aperture of a main lens. We suggest the electrically selective or tunable baseline stereo vision to reduce 3D fatigue of viewers.

  3. Ultrafast laser driven micro-lens to focus and energy select MeV protons

    International Nuclear Information System (INIS)

    Toncian, Toma

    2008-05-01

    A technique for simultaneous focusing and energy selection of high-current, MeV proton beams using radial, transient electric fields (10 7 -10 10 V/m) triggered on the inner wall of a hollow micro-cylinder by an intense, sub-picosecond laser-pulse is presented. Due to the transient nature of the radial focusing field, the proposed method allows selection of a desired range out of the spectrum of the poly-energetic proton beam. This technique addresses current drawbacks of laser-accelerated proton beams, i.e. their broad spectrum and divergence at the source. This thesis presents both experimental and computational studies that led to the understanding of the physical processes driving the micro-lens. After an one side irradiation of a hollow metallic cylinder a radial electric field develops inside the cylinder. Hot electrons generated by the interaction between laser pulse and cylinder wall spread inside the cylinder generating a plasma at the wall. This plasma expands into vacuum and sustains an electric field that acts as a collecting lens on a proton beam propagating axially through the cylinder. Both focusing and the reduction of the intrinsic beam divergence from 20 deg to.3 deg for a narrow spectral range was demonstrated. By sub-aperturing the beam a narrow spectral range (δε/ε < 3%) was selected from the poly-energetic beam. The micro-lens properties are tunable allowing for optimization towards applications. Optical probing techniques and proton imaging were employed to study the spacial and temporal evolution of the field and revealed a complex physical scenario of the rise and decay of the radial electric field. Each aspect studied experimentally is interpreted using 2D PIC and ray tracing simulations. A very good agreement between the experimental and computational data is found. The PIC simulations are used to upscale the demonstrated micro-lens capabilities to the focusing of a 270 MeV proton beam, an energy relevant for medical applications such

  4. Ultrafast laser driven micro-lens to focus and energy select MeV protons

    Energy Technology Data Exchange (ETDEWEB)

    Toncian, Toma

    2008-05-15

    A technique for simultaneous focusing and energy selection of high-current, MeV proton beams using radial, transient electric fields (10{sup 7}-10{sup 10} V/m) triggered on the inner wall of a hollow micro-cylinder by an intense, sub-picosecond laser-pulse is presented. Due to the transient nature of the radial focusing field, the proposed method allows selection of a desired range out of the spectrum of the poly-energetic proton beam. This technique addresses current drawbacks of laser-accelerated proton beams, i.e. their broad spectrum and divergence at the source. This thesis presents both experimental and computational studies that led to the understanding of the physical processes driving the micro-lens. After an one side irradiation of a hollow metallic cylinder a radial electric field develops inside the cylinder. Hot electrons generated by the interaction between laser pulse and cylinder wall spread inside the cylinder generating a plasma at the wall. This plasma expands into vacuum and sustains an electric field that acts as a collecting lens on a proton beam propagating axially through the cylinder. Both focusing and the reduction of the intrinsic beam divergence from 20 deg to.3 deg for a narrow spectral range was demonstrated. By sub-aperturing the beam a narrow spectral range ({delta}{epsilon}/{epsilon} < 3%) was selected from the poly-energetic beam. The micro-lens properties are tunable allowing for optimization towards applications. Optical probing techniques and proton imaging were employed to study the spacial and temporal evolution of the field and revealed a complex physical scenario of the rise and decay of the radial electric field. Each aspect studied experimentally is interpreted using 2D PIC and ray tracing simulations. A very good agreement between the experimental and computational data is found. The PIC simulations are used to upscale the demonstrated micro-lens capabilities to the focusing of a 270 MeV proton beam, an energy relevant

  5. Optical assembly of bio-hybrid micro-robots.

    Science.gov (United States)

    Barroso, Álvaro; Landwerth, Shirin; Woerdemann, Mike; Alpmann, Christina; Buscher, Tim; Becker, Maike; Studer, Armido; Denz, Cornelia

    2015-04-01

    The combination of micro synthetic structures with bacterial flagella motors represents an actual trend for the construction of self-propelled micro-robots. The development of methods for fabrication of these bacteria-based robots is a first crucial step towards the realization of functional miniature and autonomous moving robots. We present a novel scheme based on optical trapping to fabricate living micro-robots. By using holographic optical tweezers that allow three-dimensional manipulation in real time, we are able to arrange the building blocks that constitute the micro-robot in a defined way. We demonstrate exemplarily that our method enables the controlled assembly of living micro-robots consisting of a rod-shaped prokaryotic bacterium and a single elongated zeolite L crystal, which are used as model of the biological and abiotic components, respectively. We present different proof-of-principle approaches for the site-selective attachment of the bacteria on the particle surface. The propulsion of the optically assembled micro-robot demonstrates the potential of the proposed method as a powerful strategy for the fabrication of bio-hybrid micro-robots.

  6. Relative biocompatibility of micro-hybrid and nano-hybrid light-activated composite resins.

    Science.gov (United States)

    Olabisi Arigbede, Abiodun; Folasade Adeyemi, Bukola; Femi-Akinlosotu, Omowumi

    2017-01-01

    Background. In vitro studies have revealed a direct association between resin content and cytotoxicity of composite resins; however, implantation studies in this regard are sparse. This study investigates the relationship between filler content of composite resins and biocompatibility. Methods. This research employed twelve 180‒200-gr male Wistar rats, 1 nano-hybrid (Prime-Dent Inc.) and 1 micro-hybrid (Medental Inc.) composite resins containing 74% and 80‒90% filler content, respectively. The samples were assessed on the 2nd, 14th and 90th day of implantation. Four rats were allocated to each day in this experimental study. A section of 1.5mm long cured nano-hybrid and micro-hybrid materials were implanted into the right and left upper and lower limbs of the rats, respectively. Eight samples were generated on each day of observation. Inflammation was graded according to the criteria suggested by Orstavik and Major. Pearson's chi-squared test was employed to determine the relationship between the tissue responses of the two materials. Statistical significance was set at P resin had a score of 3.0 for cellular inflammation. On the 14th day, the micro-hybrid resin also exhibited a lower average grade for cellular inflammation. On the 90th day, the micro-hybrid resin had a higher grade of inflammation (0.9) compared to 0.3 recorded for nano-hybrid. The composite resins with higher filler content elicited a significantly lower grade of inflammation irrespective of the duration (χ=20.000, df=8, P=0.010) while the composite resins with lower filler content elicited a significantly lower inflammatory response on the 90th day (χ=4.000, df=1, P=0.046). Conclusion. The composite resins with higher filler content generally elicited significantly lower grades of inflammation, and the composite resins with lower filler content exhibited significantly lower inflammatory response on the 90th day of implantation.

  7. Performance of a slow positron beam using a hybrid lens design

    International Nuclear Information System (INIS)

    Cheung, C.K.; Naik, P.S.; Beling, C.D.; Fung, S.; Weng, H.M.

    2006-01-01

    The University of Hong Kong positron beam employs conventional magnetic field transport to the target, but has a special hybrid lens design around the positron moderator that allows the beam to be focused to millimeter spot sizes at the target. The good focusing capabilities of the beam are made possible by extracting work-function positrons from the moderator in a magnetic field free region using a conventional Soa lens thus minimizing beam canonical angular momentum. An Einzel lens is used to focus the positrons into the magnetic funnel at the end of transportation magnetic field while at the same time bringing up the beam energy to the intermediate value of 7.5 keV. The beam is E x B filtered at this intermediate energy. The final beam energy is obtained by floating the Soa-Einzel system, E x B filter and flight tube, and accelerating the positrons just before the target. External beam steering saddle coils fine tune the position, and the magnetic field around the target chamber is adjusted so as to keep one of the beam foci always on the target. The system is fully computer controlled. Variable energy-Doppler broadened annihilation radiation (VEDBAR) data for a GaN sample are shown which demonstrate the performance of the positron beam system

  8. Development and applications of grazing exit micro X-ray fluorescence instrument using a polycapillary X-ray lens

    International Nuclear Information System (INIS)

    Emoto, T.; Sato, Y.; Konishi, Y.; Ding, X.; Tsuji, K.

    2004-01-01

    A polycapillary X-ray lens is an effective optics to obtain a μm-size X-ray beam for micro-X-ray fluorescence spectrometry (μ-XRF). We developed a μ-XRF instrument using a polycapillary X-ray lens, which also enabled us to perform Grazing Exit μ-XRF (GE-μ-XRF). The evaluated diameter of the primary X-ray beam was 48 μm at the focal distance of the X-ray lens. Use of this instrument enabled two-dimensional mapping of the elemental distributions during growth of the plant 'Quinoa'. The results of the mapping revealed elemental transition during growth. In addition, a small region of thin film was analyzed by GE-μ-XRF. We expect that GE-μ-XRF will become an effective method of estimating the film thickness of a small region

  9. Development and applications of grazing exit micro X-ray fluorescence instrument using a polycapillary X-ray lens

    Energy Technology Data Exchange (ETDEWEB)

    Emoto, T.; Sato, Y.; Konishi, Y.; Ding, X.; Tsuji, K. E-mail: tsuji@a-chem.eng.osaka-cu.ac.jp

    2004-08-31

    A polycapillary X-ray lens is an effective optics to obtain a {mu}m-size X-ray beam for micro-X-ray fluorescence spectrometry ({mu}-XRF). We developed a {mu}-XRF instrument using a polycapillary X-ray lens, which also enabled us to perform Grazing Exit {mu}-XRF (GE-{mu}-XRF). The evaluated diameter of the primary X-ray beam was 48 {mu}m at the focal distance of the X-ray lens. Use of this instrument enabled two-dimensional mapping of the elemental distributions during growth of the plant 'Quinoa'. The results of the mapping revealed elemental transition during growth. In addition, a small region of thin film was analyzed by GE-{mu}-XRF. We expect that GE-{mu}-XRF will become an effective method of estimating the film thickness of a small region.

  10. Hybrid 3D printing by bridging micro/nano processes

    International Nuclear Information System (INIS)

    Yoon, Hae-Sung; Jang, Ki-Hwan; Kim, Eunseob; Lee, Hyun-Taek; Ahn, Sung-Hoon

    2017-01-01

    A hybrid 3D printing process was developed for multiple-material/freeform nano-scale manufacturing. The process consisted of aerodynamically focused nanoparticle (AFN) printing, micro-machining, focused ion beam milling, and spin-coating. Theoretical and experimental investigations were carried out to improve the compatibility of each of the processes, enabling bridging of various different techniques. The resulting hybrid process could address the limitations of individual processes, enabling improved process scaling and dimensional degrees of freedom, without losing the advantages of the existing processes. The minimum structure width can be reduced to 50 nm using undercut structures. In addition, AFN printing employs particle impact for adhesion, and various inorganic materials are suitable for printing, including metals and functional ceramics. Using the developed system, we fabricated bi-material cantilevers for applications as a thermal actuator. The mechanical and thermal properties of the structure were investigated using an in situ measurement system, and irregular thermal phenomena due to the fabrication process were analyzed. We expect that this work will lead to improvements in the area of customized nano-scale manufacturing, as well as further improvements in manufacturing technology by combining different fabrication techniques. (paper)

  11. Hybrid 3D printing by bridging micro/nano processes

    Science.gov (United States)

    Yoon, Hae-Sung; Jang, Ki-Hwan; Kim, Eunseob; Lee, Hyun-Taek; Ahn, Sung-Hoon

    2017-06-01

    A hybrid 3D printing process was developed for multiple-material/freeform nano-scale manufacturing. The process consisted of aerodynamically focused nanoparticle (AFN) printing, micro-machining, focused ion beam milling, and spin-coating. Theoretical and experimental investigations were carried out to improve the compatibility of each of the processes, enabling bridging of various different techniques. The resulting hybrid process could address the limitations of individual processes, enabling improved process scaling and dimensional degrees of freedom, without losing the advantages of the existing processes. The minimum structure width can be reduced to 50 nm using undercut structures. In addition, AFN printing employs particle impact for adhesion, and various inorganic materials are suitable for printing, including metals and functional ceramics. Using the developed system, we fabricated bi-material cantilevers for applications as a thermal actuator. The mechanical and thermal properties of the structure were investigated using an in situ measurement system, and irregular thermal phenomena due to the fabrication process were analyzed. We expect that this work will lead to improvements in the area of customized nano-scale manufacturing, as well as further improvements in manufacturing technology by combining different fabrication techniques.

  12. Micro/nanosized refractive lens arrays formed by means of conformal thin film deposition

    International Nuclear Information System (INIS)

    Zeng Hongjun; Lajos, Robert; Elzy, Ed; Metlushko, Vitali

    2008-01-01

    We provide a 'growing' method for fabricating a microlens array with lateral size of a few microns or less. Instead of using complicated etching techniques, the method forms a spherical profile of the lens using conformal chemical vapor deposition. We have fabricated two lens arrays. One has a pitch of 1200 nm, a circular aperture 1000 nm in diameter and a sag height of 130 nm. The other array has a pitch of 600 nm, and a square aperture of 600 nm x 600 nm, with a fill factor close to 100%. The maximum profile deviation between the fabricated lens and an ideal sphere is about 11% and 14% respectively. The calculation indicates that the curvature difference of the profile of the square lens in the orthogonal and diagonal direction is 5.5%. The roughness of the lens is measured as approximately 6 nm

  13. Hybrid tooling technologies and standardization for the manufacturing of inserts for micro injection molding

    DEFF Research Database (Denmark)

    Tosello, Guido; Fillon, Bertrand; Azcarate, Sabino

    2007-01-01

    This paper is based on the European Platform’s activities within the 4M Network of Excellence “Multi-Material Micro Manufacturing”. To overpass limitations of the current existing micro tooling capabilities, a new generation of micro hybrid tooling technologies for micro replication was developed....... A metrological approach was applied to standardize the employed tooling processes (micro milling, µEDM, laser micromachining, electrochemical µ-milling). The micro tools were then tested with different polymers (PP, PP + nano fillers, PC, COC). The paper provides a comparison of these technologies concerning...

  14. Enhanced depth-of-field of an integral imaging microscope using a bifocal holographic optical element-micro lens array.

    Science.gov (United States)

    Kwon, Ki-Chul; Lim, Young-Tae; Shin, Chang-Won; Erdenebat, Munkh-Uchral; Hwang, Jae-Moon; Kim, Nam

    2017-08-15

    We propose and implement an integral imaging microscope with extended depth-of-field (DoF) using a bifocal holographic micro lens array (MLA). The properties of the two MLAs are switched via peristrophic multiplexing, where different properties of the MLA are recorded onto the single holographic optical element (HOE). The recorded MLA properties are perpendicular to each other: after the first mode is recorded, the HOE is rotated by 90° clockwise, and the second mode is recorded. The experimental results confirm that the DoF of the integral imaging microscopy system is extended successfully by using the bifocal MLA.

  15. Light-focusing human micro-lenses generated from pluripotent stem cells model lens development and drug-induced cataract in vitro.

    Science.gov (United States)

    Murphy, Patricia; Kabir, Md Humayun; Srivastava, Tarini; Mason, Michele E; Dewi, Chitra U; Lim, Seakcheng; Yang, Andrian; Djordjevic, Djordje; Killingsworth, Murray C; Ho, Joshua W K; Harman, David G; O'Connor, Michael D

    2018-01-09

    Cataracts cause vision loss and blindness by impairing the ability of the ocular lens to focus light onto the retina. Various cataract risk factors have been identified, including drug treatments, age, smoking and diabetes. However, the molecular events responsible for these different forms of cataract are ill-defined, and the advent of modern cataract surgery in the 1960s virtually eliminated access to human lenses for research. Here, we demonstrate large-scale production of light-focusing human micro-lenses from spheroidal masses of human lens epithelial cells purified from differentiating pluripotent stem cells. The purified lens cells and micro-lenses display similar morphology, cellular arrangement, mRNA expression and protein expression to human lens cells and lenses. Exposing the micro-lenses to the emergent cystic fibrosis drug Vx-770 reduces micro-lens transparency and focusing ability. These human micro-lenses provide a powerful and large-scale platform for defining molecular disease mechanisms caused by cataract risk factors, for anti-cataract drug screening and for clinically relevant toxicity assays. © 2018. Published by The Company of Biologists Ltd.

  16. Fabrication of an eyeball-like spherical micro-lens array using extrusion for optical fiber coupling

    International Nuclear Information System (INIS)

    Shen, S C; Huang, J C; Pan, C T; Chao, C H; Liu, K H

    2009-01-01

    Batch fabrication of an eyeball-like spherical micro-lens array (ESMA) not only can reduce micro assembly cost, but also can replace conventional ball lenses or costly gradient refractive index without sacrificing performance. Compared to the conventional half-spherical micro-lenses, the ESMA is an eyeball-like spherical lens which can focus light in all directions, thus providing application flexibility for optical purposes. The current ESMA is made of photoresist SU-8 using the extrusion process instead of the traditional thermal reflow process. For the process of an ESMA, this research develops a new process at ambient temperature by spin-coating SU-8 on a surface of a silicon wafer which serves as an extrusion plate and extruding it through a nozzle to form an ESMA. This nozzle consists of a nozzle orifice and nozzle cavity. The nozzle orifice is defined and made of SU-8 photoresist using ultra-violet lithography, which exhibits good mechanical property. The fabrication process of a nozzle cavity employs bulk micromachining to fabricate the cavities. Next, viscous SU-8 spun on the extrusion plate is extruded through the nozzle orifice to form an ESMA. Based on the effect of surface tension, by varying the amount of SU-8 on the plate extruded through different nozzle orifices, various diameters of ESMA can be fabricated. In this paper, a 4 × 4 ESMA with a numerical aperture of about 0.38 and diameters ranging from 60 to 550 µm is fabricated. Optical measurements indicate a diameter variance within 3% and the maximum coupling efficiency is approximately 62% when the single mode fiber is placed at a distance of 10 µm from the ESMA. The research has proved that the extrusion fabrication process of an ESMA is capable of enhancing the coupling efficiency

  17. Raman micro-spectroscopy analysis of human lens epithelial cells exposed to a low-dose-range of ionizing radiation

    Science.gov (United States)

    Allen, Christian Harry; Kumar, Achint; Qutob, Sami; Nyiri, Balazs; Chauhan, Vinita; Murugkar, Sangeeta

    2018-01-01

    Recent findings in populations exposed to ionizing radiation (IR) indicate dose-related lens opacification occurs at much lower doses (micro-spectroscopy was used to investigate the effects of varying doses of radiation, ranging from 0.01 Gy to 5 Gy, on human lens epithelial (HLE) cells which were chemically fixed 24 h post-irradiation. Raman spectra were acquired from the nucleus and cytoplasm of the HLE cells. Spectra were collected from points in a 3  ×  3 grid pattern and then averaged. The raw spectra were preprocessed and principal component analysis followed by linear discriminant analysis was used to discriminate between dose and control for 0.25, 0.5, 2, and 5 Gy. Using leave-one-out cross-validation accuracies of greater than 74% were attained for each dose/control combination. The ultra-low doses 0.01 and 0.05 Gy were included in an analysis of band intensities for Raman bands found to be significant in the linear discrimination, and an induced repair model survival curve was fit to a band-difference-ratio plot of this data, suggesting HLE cells undergo a nonlinear response to low-doses of IR. A survival curve was also fit to clonogenic assay data done on the irradiated HLE cells, showing a similar nonlinear response.

  18. Analysis of fixed tilt and sun tracking photovoltaic–micro wind based hybrid power systems

    International Nuclear Information System (INIS)

    Sinha, Sunanda; Chandel, S.S.

    2016-01-01

    Graphical abstract: 6 kW_p photovoltaic–micro wind based hybrid power system analysis in a Indian Western Himalayan location. - Highlights: • Power generation by a roof mounted photovoltaic–micro wind hybrid system is explored. • Optimum hybrid configurations using fixed and sun tracking photovoltaic systems are determined. • Analysis of hybrid systems with optimally tilted and different sun tracking systems is presented. • Two axis sun tracking systems are found to generate 4.88–26.29% more energy than fixed tilt system. • Hybrid system installed at optimum tilt angle is found to be cost effective than a sun tracking system. - Abstract: In this study fixed tilt and sun tracking photovoltaic based micro wind hybrid power systems are analyzed along with determining the optimum configurations for a 6 kW_p roof mounted micro wind based hybrid system using fixed and tracking photovoltaic systems to enhance the power generation potential in a low windy Indian hilly terrain with good solar resource. The main objective of the study is to enhance power generation by focusing on photovoltaic component of the hybrid system. A comparative power generation analysis of different configurations of hybrid systems with fixed tilt, monthly optimum tilt, yearly optimum tilt and 6 different sun tracking photovoltaic systems is carried out using Hybrid Optimization Model for Electric Renewables. Monthly and seasonal optimum tilt angles determined for the location vary between 0° and 60° with annual optimum tilt angle as 29.25°. The optimum configurations for all sun tracking systems except for the two axis tracking system is found to be 7 kW_p photovoltaic system, one 5 kW_p wind turbine, 10 batteries and a 2 kW_p inverter. The optimum configuration for two axis tracking system and two types of fixed tilt systems, is found to be a 8 kW_p photovoltaic system, one 5 kW_p wind turbine, 10 batteries and a 2 kW_p inverter. The results show that horizontal axis with

  19. Hybrid Spectral Micro-CT: System Design, Implementation, and Preliminary Results

    CERN Document Server

    Bennett, James R; Xu, Qiong; Yu, Hengyong; Walsh, Michael; Butler, Anthony; Butler, Phillip; Cao, Guohua; Mohs, Aaron; Wang, Ge

    2014-01-01

    Spectral CT has proven an important development in biomedical imaging, and there have been several publications in the past years demonstrating its merits in pre-clinical and clinical applications. In 2012, Xu et al. reported that near-term implementation of spectral micro-CT could be enhanced by a hybrid architecture: a narrow-beam spectral "interior" imaging chain integrated with a traditional wide-beam "global" imaging chain. This hybrid integration coupled with compressive sensing (CS)-based interior tomography demonstrated promising results for improved contrast resolution, and decreased system cost and radiation dose. The motivation for the current study is implementation and evaluation of the hybrid architecture with a first-of-its-kind hybrid spectral micro-CT system. Preliminary results confirm improvements in both contrast and spatial resolution. This technology is shown to merit further investigation and potential application in future spectral CT scanner design.

  20. Stability assessment of a multi-port power electronic interface for hybrid micro-grid applications

    Science.gov (United States)

    Shamsi, Pourya

    Migration to an industrial society increases the demand for electrical energy. Meanwhile, social causes for preserving the environment and reducing pollutions seek cleaner forms of energy sources. Therefore, there has been a growth in distributed generation from renewable sources in the past decade. Existing regulations and power system coordination does not allow for massive integration of distributed generation throughout the grid. Moreover, the current infrastructures are not designed for interfacing distributed and deregulated generation. In order to remedy this problem, a hybrid micro-grid based on nano-grids is introduced. This system consists of a reliable micro-grid structure that provides a smooth transition from the current distribution networks to smart micro-grid systems. Multi-port power electronic interfaces are introduced to manage the local generation, storage, and consumption. Afterwards, a model for this micro-grid is derived. Using this model, the stability of the system under a variety of source and load induced disturbances is studied. Moreover, pole-zero study of the micro-grid is performed under various loading conditions. An experimental setup of this micro-grid is developed, and the validity of the model in emulating the dynamic behavior of the system is verified. This study provides a theory for a novel hybrid micro-grid as well as models for stability assessment of the proposed micro-grid.

  1. Performance evaluation of hybrid modified micro-channel solar cell ...

    African Journals Online (AJOL)

    user

    International Journal of Engineering, Science and Technology ... of hybrid PVT solar air heater had been proposed in the past. ...... president of Bag Energy Research Society (BERS:www.bers.in) which is responsible for energy education in ...

  2. Design and implementation of a hybrid circuit system for micro sensor signal processing

    International Nuclear Information System (INIS)

    Wang Zhuping; Chen Jing; Liu Ruqing

    2011-01-01

    This paper covers a micro sensor analog signal processing circuit system (MASPS) chip with low power and a digital signal processing circuit board implementation including hardware connection and software design. Attention has been paid to incorporate the MASPS chip into the digital circuit board. The ultimate aim is to form a hybrid circuit used for mixed-signal processing, which can be applied to a micro sensor flow monitoring system. (semiconductor integrated circuits)

  3. Bio-hybrid micro/nanodevices powered by flagellar motor: challenges and strategies

    Directory of Open Access Journals (Sweden)

    Jin-Woo eKim

    2015-07-01

    Full Text Available Molecular motors, which are precision-engineered by nature, offer exciting possibilities for bio-hybrid engineered systems. They could enable real applications ranging from micro/nano fluidics, to biosensing, to medical diagnoses. This review describes the fundamental biological insights and fascinating potentials of these remarkable sensing and actuation machines, in particular bacterial flagellar motors, as well as their engineering perspectives with regard to applications in bio-engineered hybrid systems and nanobiotechnology.

  4. Towards micro-assembly of hybrid MOEMS components on a reconfigurable silicon free-space micro-optical bench

    International Nuclear Information System (INIS)

    Bargiel, S; Gorecki, C; Rabenorosoa, K; Clévy, C; Lutz, P

    2010-01-01

    The 3D integration of hybrid chips is a viable approach for the micro-optical technologies to reduce the costs of assembly and packaging. In this paper a technology platform for the hybrid integration of MOEMS components on a reconfigurable silicon free-space micro-optical bench (FS-MOB) is presented. In this approach a desired optical component (e.g. micromirror, microlens) is integrated with a removable and adjustable silicon holder which can be manipulated, aligned and fixed in the precisely etched rail of the silicon baseplate by use of a robotic micro-assembly station. An active-based gripping system allows modification of the holder position on the baseplate with nanometre precision. The fabrication processes of the micromachined parts of the micro-optical bench, based on bulk micromachining of standard silicon wafer and SOI wafer, are described. The successful assembly of the holders, equipped with a micromirror and a refractive glass ball microlens, on the baseplate rail is demonstrated.

  5. Optimizing laser beam profiles using micro-lens arrays for efficient material processing: applications to solar cells

    Science.gov (United States)

    Hauschild, Dirk; Homburg, Oliver; Mitra, Thomas; Ivanenko, Mikhail; Jarczynski, Manfred; Meinschien, Jens; Bayer, Andreas; Lissotschenko, Vitalij

    2009-02-01

    High power laser sources are used in various production tools for microelectronic products and solar cells, including the applications annealing, lithography, edge isolation as well as dicing and patterning. Besides the right choice of the laser source suitable high performance optics for generating the appropriate beam profile and intensity distribution are of high importance for the right processing speed, quality and yield. For industrial applications equally important is an adequate understanding of the physics of the light-matter interaction behind the process. In advance simulations of the tool performance can minimize technical and financial risk as well as lead times for prototyping and introduction into series production. LIMO has developed its own software founded on the Maxwell equations taking into account all important physical aspects of the laser based process: the light source, the beam shaping optical system and the light-matter interaction. Based on this knowledge together with a unique free-form micro-lens array production technology and patented micro-optics beam shaping designs a number of novel solar cell production tool sub-systems have been built. The basic functionalities, design principles and performance results are presented with a special emphasis on resilience, cost reduction and process reliability.

  6. Waveguide-coupled micro-ball lens array suitable for mass fabrication

    NARCIS (Netherlands)

    Chang, Lantian; Dijkstra, Meindert; Ismail, Nur; Pollnau, Markus; de Ridder, René M; Wörhoff, Kerstin; Subramaniam, Vinod; Kanger, Johannes S

    2015-01-01

    We demonstrate a fabrication procedure for the direct integration of micro-ball lenses on planar integrated optical channel waveguide chips with the aim to reduce the divergence of light that arises from the waveguide in both horizontal and vertical directions. Fabrication of the lenses is based on

  7. DNA-DNA hybridization determined in micro-wells using covalent attachment of DNA

    DEFF Research Database (Denmark)

    Christensen, H.; Angen, Øystein; Mutters, R.

    2000-01-01

    The present study was aimed at reducing the time and labour used to perform DNA-DNA hybridizations for classification of bacteria at the species level. A micro-well-format DNA hybridization method was developed and validated. DNA extractions were performed by a small-scale method and DNA...... was sheared mechanically into fragments of between 400 and 700 bases. The hybridization conditions were calibrated according to DNA similarities obtained by the spectrophotometric method using strains within the family Pasteurellaceae, Optimal conditions were obtained with 300 ng DNA added per well and bound...... by covalent attachment to NucleoLink. Hybridization was performed with 500 ng DNA, 5% (w/w) of which was labelled with photo-activatable biotin (competitive hybridization) for 2.5 h at 65 degrees C in 2 x SSC followed by stringent washing with 2 x SSC at the same temperature. The criteria for acceptance...

  8. Application specific integrated circuits and hybrid micro circuits for nuclear instrumentation

    International Nuclear Information System (INIS)

    Chandratre, V.B.; Sukhwani, Menka; Mukhopadhyay, P.K.; Shastrakar, R.S.; Sudheer, M.; Shedam, V.; Keni, Anubha

    2009-01-01

    Rapid development in semiconductor technology, sensors, detectors and requirements of high energy physics experiments as well as advances in commercially available nuclear instruments have lead to challenges for instrumentation. These challenges are met with development of Application Specific Integrated Circuits and Hybrid Micro Circuits. This paper discusses various activities in ASIC and HMC development in Bhabha Atomic Research Centre. (author)

  9. In vitro micro-propagation of Longiflorum-Asiatic (LA) hybrids lily ...

    African Journals Online (AJOL)

    Bulblets propagation by tissue culture was one of the key techniques in the production of lily (Lilium) bulbs. Therefore, in vitro micro propagation of lily bulblets was studied in detail in this paper. L A hybrids lily cultivar 'eyeliner' was selected as the materials. By using the method of orthogonal design, the following were ...

  10. Issues regarding the modelling and simulation of hybrid micro grid systems

    Science.gov (United States)

    Szeidert, I.; Filip, I.; Prostean, O.

    2016-02-01

    The main followed objectives within control strategies dedicated to hybrid micro grid systems (wind/hydro/solar), that operate based on maximum power point tracking (MPPT) techniques are to improve the conversion systems efficiency and to maintain the quality of the produced electrical energy (the voltage and power factor control). One of the main goals of maximum power point tracking strategy is to achieve the harvesting of the maximal possible energy within a pre-set time period. In order to implement the control strategies for micro grid systems that operate at time variable parameter, there are usually required specific transducers (anemometer for wind speed measurement, optical rotational transducers, taco generators, etc.). In the technical literature there are presented several variants of the MPPT techniques, which are particularized at several applications (wind energy conversion systems, solar systems, hydro plants and micro grid hybrid systems). The maximum power point tracking implementations are mainly based on two-level architecture. The inferior level controls the primary variables, while the superior level represents the MPPT control structure. In the paper, authors present some micro grid structures proposed at Politehnica University Timisoara within the frame of a research grant. The paper is focused on the application of MPPT strategies on hybrid micro grid systems. There are presented several structures and control strategies and are highlighted their advantages and disadvantages, together with practical implementation guidelines.

  11. Motion-free hybrid design laser beam propagation analyzer using a digital micromirror device and a variable focus liquid lens.

    Science.gov (United States)

    Sheikh, Mumtaz; Riza, Nabeel A

    2010-06-01

    To the best of our knowledge, we propose the first motion-free laser beam propagation analyzer with a hybrid design using a digital micromirror device (DMD) and a liquid electronically controlled variable focus lens (ECVFL). Unlike prior analyzers that require profiling the beam at multiple locations along the light propagation axis, the proposed analyzer profiles the beam at the same plane for multiple values of the ECVFL focal length, thus eliminating beam profiler assembly motion. In addition to measuring standard Gaussian beam parameters, the analyzer can also be used to measure the M(2) beam propagation parameter of a multimode beam. Proof-of-concept beam parameter measurements with the proposed analyzer are successfully conducted for a 633 nm laser beam. Given the all-digital nature of the DMD-based profiling and all-analog motion-free nature of the ECVFL beam focus control, the proposed analyzer versus prior art promises better repeatability, speed, and reliability.

  12. Bio-Inspired Wide-Angle Broad-Spectrum Cylindrical Lens Based on Reflections from Micro-Mirror Array on a Cylindrical Elastomeric Membrane

    Directory of Open Access Journals (Sweden)

    Chi-Chieh Huang

    2014-06-01

    Full Text Available We present a wide-angle, broad-spectrum cylindrical lens based on reflections from an array of three-dimensional, high-aspect-ratio micro-mirrors fabricated on a cylindrical elastomeric substrate, functionally inspired by natural reflecting superposition compound eyes. Our device can perform one-dimensional focusing and beam-shaping comparable to conventional refraction-based cylindrical lenses, while avoiding chromatic aberration. The focal length of our cylindrical lens is 1.035 mm, suitable for micro-optical systems. Moreover, it demonstrates a wide field of view of 152° without distortion, as well as modest spherical aberrations. Our work could be applied to diverse applications including laser diode collimation, barcode scanning, holography, digital projection display, microlens arrays, and optical microscopy.

  13. Hybrid Micro-Hydro Power Generation Development in Endau Rompin National Park Johor, Malaysia

    Directory of Open Access Journals (Sweden)

    Yusop Azli

    2017-01-01

    Full Text Available Micro-Hydro electrical power systems are very useful for remote area electrification which does not had supply from the national grid. On the contrary, this area has river streams with high potential for micro-hydro power generation. As such, the UTHM ECO-Hydro Team embarked on a project for erecting a micro-hydro power plant with collaboration with National Education Research Center (NERC, Johor National Park Corporation in Endau Rompin. The existing power generation in this area at present is by using diesel generator gives negative impact on finance and environment in the long run. It supplies power to several including library, offices, open laboratory, chalets and dorms.. At the moment, the micro-hydro system complements the diesel generator, thus becoming a hybrid power generation system.

  14. Micro-Processes of Employees in a Hybrid Organization

    DEFF Research Database (Denmark)

    Svenningsen, Virginie; Boxenbaum, Eva; Ravasi, Davide

    actors engaged in the energy transition. We draw on the literature on institutional logics and hybrid organizations to examine how employees of this French energy corporation deal with this institutionally complex environment. Our findings point to three strategies that individuals use to cope......The present article examines how employees cope with an organizational setting that is institutionally complex. The empirical setting is a French energy corporation that simultaneously pursues a logic of science and a logic of market through multiple research partnerships with public and private...

  15. Hybrid Systems: Cold Atoms Coupled to Micro Mechanical Oscillators =

    Science.gov (United States)

    Montoya Monge, Cris A.

    Micro mechanical oscillators can serve as probes in precision measurements, as transducers to mediate photon-phonon interactions, and when functionalized with magnetic material, as tools to manipulate spins in quantum systems. This dissertation includes two projects where the interactions between cold atoms and mechanical oscillators are studied. In one of the experiments, we have manipulated the Zeeman state of magnetically trapped Rubidium atoms with a magnetic micro cantilever. The results show a spatially localized effect produced by the cantilever that agrees with Landau-Zener theory. In the future, such a scalable system with highly localized interactions and the potential for single-spin sensitivity could be useful for applications in quantum information science or quantum simulation. In a second experiment, work is in progress to couple a sample of optically trapped Rubidium atoms to a levitated nanosphere via an optical lattice. This coupling enables the cooling of the center-of-mass motion of the nanosphere by laser cooling the atoms. In this system, the atoms are trapped in the optical lattice while the sphere is levitated in a separate vacuum chamber by a single-beam optical tweezer. Theoretical analysis of such a system has determined that cooling the center-of-mass motion of the sphere to its quantum ground state is possible, even when starting at room temperature, due to the excellent environmental decoupling achievable in this setup. Nanospheres cooled to the quantum regime can provide new tests of quantum behavior at mesoscopic scales and have novel applications in precision sensing.

  16. Hybrid Energy System Design of Micro Hydro-PV-biogas Based Micro-grid

    Science.gov (United States)

    Nishrina; Abdullah, A. G.; Risdiyanto, A.; Nandiyanto, ABD

    2017-03-01

    Hybrid renewable energy system is an arrangement of one or more sources of renewable energy and also conventional energy. This paper describes a simulation results of hybrid renewable power system based on the available potential in an educational institution in Indonesia. HOMER software was used to simulate and analyse both in terms of optimization and economic terms. This software was developed through 3 main principles; simulation, optimization, and sensitivity analysis. Generally, the presented results show that the software can demonstrate a feasible hybrid power system as well to be realized. The entire demand in case study area can be supplied by the system configuration and can be met by ¾ of electricity production. So, there are ¼ of generated energy became an excess electricity.

  17. Fluorescence In Situ Hybridization for MicroRNA Detection in Archived Oral Cancer Tissues

    Directory of Open Access Journals (Sweden)

    Zonggao Shi

    2012-01-01

    Full Text Available The noncoding RNA designated as microRNA (miRNA is a large group of small single-stranded regulatory RNA and has generated wide-spread interest in human disease studies. To facilitate delineating the role of microRNAs in cancer pathology, we sought to explore the feasibility of detecting microRNA expression in formalin-fixed paraffin-embedded (FFPE tissues. Using FFPE materials, we have compared fluorescent in situ hybridization (FISH procedures to detect miR-146a with (a different synthetic probes: regular custom DNA oligonucleotides versus locked nucleic acid (LNA incorporated DNA oligonucleotides; (b different reporters for the probes: biotin versus digoxigenin (DIG; (c different visualization: traditional versus tyramide signal amplification (TSA system; (d different blocking reagents for endogenous peroxidase. Finally, we performed miR-146a FISH on a commercially available oral cancer tissue microarray, which contains 40 cases of oral squamous cell carcinoma (OSCC and 10 cases of normal epithelia from the human oral cavity. A sample FISH protocol for detecting miR-146a is provided. In summary, we have established reliable in situ hybridization procedures for detecting the expression of microRNA in FFPE oral cancer tissues. This method is an important tool for studies on the involvement of microRNA in oral cancer pathology and may have potential prognostic or diagnostic value.

  18. Mathematical Modelling of a Hybrid Micro-Cogeneration Group Based on a Four Stroke Diesel Engine

    Directory of Open Access Journals (Sweden)

    Apostol Valentin

    2014-06-01

    Full Text Available The paper presents a part of the work conducted in the first stage of a Research Grant called ”Hybrid micro-cogeneration group of high efficiency equipped with an electronically assisted ORC” acronym GRUCOHYB. The hybrid micro-cogeneration group is equipped with a four stroke Diesel engine having a maximum power of 40 kW. A mathematical model of the internal combustion engine is presented. The mathematical model is developed based on the Laws of Thermodynamics and takes into account the real, irreversible processes. Based on the mathematical model a computation program was developed. The results obtained were compared with those provided by the Diesel engine manufacturer. Results show a very high correlation between the manufacturer’s data and the simulation results for an engine running at 100% load. Future developments could involve using an exergetic analysis to show the ability of the ORC to generate electricity from recovered heat

  19. Extension of hybrid micro-depletion model for decay heat calculation in the DYN3D code

    International Nuclear Information System (INIS)

    Bilodid, Yurii; Fridman, Emil; Shwageraus, E.

    2017-01-01

    This work extends the hybrid micro-depletion methodology, recently implemented in DYN3D, to the decay heat calculation by accounting explicitly for the heat contribution from the decay of each nuclide in the fuel.

  20. Extension of hybrid micro-depletion model for decay heat calculation in the DYN3D code

    Energy Technology Data Exchange (ETDEWEB)

    Bilodid, Yurii; Fridman, Emil [Helmholtz-Zentrum Dresden-Rossendorf e.V., Dresden (Germany). Reactor Safety; Kotlyar, D. [Georgia Institute of Technology, Atlanta, GA (United States); Shwageraus, E. [Cambridge Univ. (United Kingdom)

    2017-06-01

    This work extends the hybrid micro-depletion methodology, recently implemented in DYN3D, to the decay heat calculation by accounting explicitly for the heat contribution from the decay of each nuclide in the fuel.

  1. Hybrid microcircuit metallization system for the SLL micro actuator

    International Nuclear Information System (INIS)

    Hampy, R.E.; Knauss, G.L.; Komarek, E.E.; Kramer, D.K.; Villaueva, J.

    1976-03-01

    A thin film technique developed for the SLL Micro Actuator in which both gold and aluminum can be incorporated on sapphire or fine grained alumina substrates in a two-level metallization system is described. Tungsten is used as a lateral transition metal permitting electrical contact between the gold and aluminum without the two metals coming in physical contact. Silicon dioxide serves as an insulator between the tungsten and aluminum for crossover purposes, and vias through the silicon dioxide permit interconnections where desired. Tungsten-gold is the first level conductor except at crossovers where tungsten only is used and aluminum is the second level conductor. Sheet resistances of the two levels can be as low as 0.01 ohm/square. Line widths and spaces as small as 0.025 mm can be attained. A second layer of silicon dioxide is deposited over the metallization and opened for all gold and aluminum bonding areas. The metallization system permits effective interconnection of a mixture of devices having both gold and aluminum terminations without creating undesirable gold-aluminum interfaces. Processing temperatures up to 400 0 C can be tolerated for short times without effect on bondability, conductor, and insulator characteristics, thus permitting silicon-gold eutectic die attachment, component soldering, and higher temperatures during gold lead bonding. Tests conducted on special test pattern circuits indicate good stability over the temperature range -55 to +150 0 C. Aging studies indicate no degradation in characteristics in tests of 500 h duration at 150 0 C

  2. Hybrid integrated single-wavelength laser with silicon micro-ring reflector

    Science.gov (United States)

    Ren, Min; Pu, Jing; Krishnamurthy, Vivek; Xu, Zhengji; Lee, Chee-Wei; Li, Dongdong; Gonzaga, Leonard; Toh, Yeow T.; Tjiptoharsono, Febi; Wang, Qian

    2018-02-01

    A hybrid integrated single-wavelength laser with silicon micro-ring reflector is demonstrated theoretically and experimentally. It consists of a heterogeneously integrated III-V section for optical gain, an adiabatic taper for light coupling, and a silicon micro-ring reflector for both wavelength selection and light reflection. Heterogeneous integration processes for multiple III-V chips bonded to an 8-inch Si wafer have been developed, which is promising for massive production of hybrid lasers on Si. The III-V layer is introduced on top of a 220-nm thick SOI layer through low-temperature wafer-boning technology. The optical coupling efficiency of >85% between III-V and Si waveguide has been achieved. The silicon micro-ring reflector, as the key element of the hybrid laser, is studied, with its maximized reflectivity of 85.6% demonstrated experimentally. The compact single-wavelength laser enables fully monolithic integration on silicon wafer for optical communication and optical sensing application.

  3. Large Signal Stabilization of Hybrid AC/DC Micro-Grids Using Nonlinear Robust Controller

    Directory of Open Access Journals (Sweden)

    Reza Pejmanfar

    2017-12-01

    Full Text Available This paper presents a robust nonlinear integrated controller to improve stability of hybrid AC/DC micro-grids under islanding mode. The proposed controller includes two independent controllers where each one is responsible to control one part of the system. First controller will improve the stability of input DC/DC converter. Using this controller, the voltage of DC bus is fully stabilized such that when a large disturbance occurs, its voltage will become constant without any significant dynamic. The necessity of DC bus regulation which has not been considered in previous studies, is imminent as it not only improves voltage stability of the micro-grid but also protects consumers which are directly connected to the DC bus, against voltage variations. Frequency stability of the micro-grid is provided by the second proposed controller which is applied to output DC/AC converter of the micro-grid. Adaptive method is used to make the controllers proposed in this paper, robust. Duty cycle of converters switches are adjusted such that voltage and frequency of the micro-grid are set on the desired value in minimum possible time under transient disturbances and uncertainty of the loads as well as micro-sources characteristics.

  4. Grid-connected Photovoltaic Micro-inverter with New Hybrid Control LLC Resonant Converter

    DEFF Research Database (Denmark)

    Xingkui, Mao; Qisheng, Huang; Qingbo, Ke

    2016-01-01

    A high-efficiency photovoltaic (PV) micro-inverter consisting of two power stages i.e. a LLC resonant converter with a new hybrid control scheme and a dc-ac inverter is proposed, studied and designed in this paper. In the first power stage, the new hybrid control combining pulse-frequency modulat......A high-efficiency photovoltaic (PV) micro-inverter consisting of two power stages i.e. a LLC resonant converter with a new hybrid control scheme and a dc-ac inverter is proposed, studied and designed in this paper. In the first power stage, the new hybrid control combining pulse......-frequency modulation (PFM) and phase-shift pulse-width modulation (PS-PWM) is employed on a full-bridge LLC dc-dc converter, in order to achieve high efficiency when PV output voltage varies in a wide range. Moreover, a maximum power point tracking (MPPT) method based on power perturbation is implemented in the dc...

  5. Multiscale Hybrid Micro-Nanocomposites Based on Carbon Nanotubes and Carbon Fibers

    Directory of Open Access Journals (Sweden)

    Fawad Inam

    2010-01-01

    Full Text Available Amino-modified double wall carbon nanotube (DWCNT-NH2/carbon fiber (CF/epoxy hybrid micro-nanocomposite laminates were prepared by a resin infusion technique. DWCNT-NH2/epoxy nanocomposites and carbon fiber/epoxy microcomposites were made for comparison. Morphological analysis of the hybrid composites was performed using field emission scanning electron microscope. A good dispersion at low loadings of carbon nanotubes (CNTs in epoxy matrix was achieved by a bath ultrasonication method. Mechanical characterization of the hybrid micro-nanocomposites manufactured by a resin infusion process included three-point bending, mode I interlaminar toughness, dynamic mechanical analysis, and drop-weight impact testing. The addition of small amounts of CNTs (0.025, 0.05, and 0.1 wt% to epoxy resins for the fabrication of multiscale carbon fiber composites resulted in a maximum enhancement in flexural modulus by 35%, a 5% improvement in flexural strength, a 6% improvement in absorbed impact energy, and 23% decrease in the mode I interlaminar toughness. Hybridization of carbon fiber-reinforced epoxy using CNTs resulted in a reduction in and dampening characteristics, presumably as a result of the presence of micron-sized agglomerates.

  6. Piezoelectric properties of the new generation active matrix hybrid (micro-nano) composites

    Energy Technology Data Exchange (ETDEWEB)

    Parali, Levent, E-mail: levent.parali@cbu.edu.tr [Department of Electronics and Automation, Celal Bayar University, Manisa (Turkey); Şabikoğlu, İsrafil [Department of Physics, Celal Bayar University, Manisa (Turkey); Kurbanov, Mirza A. [Institute of Physics, Academy of Sciences of Azerbaijan, Baku (Azerbaijan)

    2014-11-01

    Highlights: • We prepared hybrid structured piezocomposites. • We examine thermostimulated depolarization of piezocomposites. • We examine frequency characteristic of piezocomposites with SiO{sub 2} and BaTiO{sub 3}. • The piezocomposites can be used in acoustic applications at 5 Hz–40 kHz. - Abstract: A hybrid piezoelectric composite structure is obtained by addition of nano-sized BaTiO{sub 3}, SiO{sub 2} to the micro-sized PZT and polymers composition. Although the PZT material itself has excellent piezoelectric properties, PZT-based composite variety is limited. Piezoelectric properties of PZT materials can be varied with an acceptor or a donor added to the material. In addition, varieties of PZT-based sensors can be increased with doping polymers which have physical-mechanical, electrophysical, thermophysical and photoelectrical properties. The active matrix hybrid structure occurs when bringing together the unique piezoelectric properties of micro-sized PZT with electron trapping properties of nano-sized insulators (BaTiO{sub 3} or SiO{sub 2}), and their piezoelectric, mechanic and electromechanic properties significantly change. In this study, the relationship between the piezoelectric constant and the coupling factor values of microstructure (PZT–PVDF) and the hybrid structure (PZT–PVDF–BaTiO{sub 3}) composite are compared. The d{sub 33} value and the coupling factor of the hybrid structure have shown an average of 54 and 62% increase according to microstructure composite, respectively. In addition, the d{sub 33} value and the coupling factor of the hybrid structure (PZT–HDPE–SiO{sub 2}) have exhibited about 68 and 52% increase according to microstructure composite (PZT–HDPE), respectively.

  7. Direct writing of micro/nano-scale patterns by means of particle lens arrays scanned by a focused diode pumped Nd:YVO4 laser

    Science.gov (United States)

    Pena, Ana; Wang, Zengbo; Whitehead, David; Li, Lin

    2010-11-01

    A practical approach to a well-known technique of laser micro/nano-patterning by optical near fields is presented. It is based on surface patterning by scanning a Gaussian laser beam through a self-assembled monolayer of silica micro-spheres on a single-crystalline silicon (Si) substrate. So far, the outcome of this kind of near-field patterning has been related to the simultaneous, parallel surface-structuring of large areas either by top hat or Gaussian laser intensity distributions. We attempt to explore the possibility of using the same technique in order to produce single, direct writing of features. This could be of advantage for applications in which only some areas need to be patterned (i.e. local area selective patterning) or single lines are required (e.g. a particular micro/nano-fluidic channel). A diode pumped Nd:YVO4 laser system (wavelength of 532 nm, pulse duration of 8 ns, repetition rate of 30 kHz) with a computer-controlled 3 axis galvanometer beam scanner was employed to write user-defined patterns through the particle lens array on the Si substrate. After laser irradiation, the obtained patterns which are in the micro-scale were composed of sub-micro/micro-holes or bumps. The micro-pattern resolution depends on the dimension of both the micro-sphere’s diameter and the beam’s spot size. The developed technique could potentially be employed to fabricate photonic crystal structures mimicking nature’s butterfly wings and anti-reflective “moth eye” arrays for photovoltaic cells.

  8. Numerical study of a hybrid jet impingement/micro-channel cooling scheme

    International Nuclear Information System (INIS)

    Barrau, Jérôme; Omri, Mohammed; Chemisana, Daniel; Rosell, Joan; Ibañez, Manel; Tadrist, Lounes

    2012-01-01

    A new hybrid jet impingement/micro-channel cooling scheme is studied numerically for use in high-heat-flux thermal management of electronic and power devices. The device is developed with the objective of improving the temperature uniformity of the cooled object. A numerical model based on the k–ω SST turbulent model is developed and validated experimentally. This model is used to carry out a parametrical characterization of the heat sink. The study shows that variations in key parameters of jet impingement and micro-channel technologies allow for the cooling scheme to obtain a wide range of temperature profiles for the cooled object. - Highlights: ► A new hybrid cooling scheme is numerically studied. ► The cooling scheme combines the benefits of jet impingement and micro-channel flows. ► The numerical model is validated by comparison with experimental results. ► The temperature distribution can be adapted to the needs of the cooled system.

  9. Selected Parameters of Micro-Jet Cooling Gases in Hybrid Spraying Process

    Directory of Open Access Journals (Sweden)

    Szczucka-Lasota B.

    2016-06-01

    Full Text Available The innovative technology, like thermal spraying with a micro-jet cooling is one of the important modification of classical ultrasonic spraying methods. Using of micro-stream with gases like argon or nitrogen allows to cool the coating immediately after spraying, and thereby reduce the time of transition during the injection of each layer. As a result of the process, the fine dispersive structure of coatings is obtained during the shorter time in comparable to the classical high velocity oxygen fuel process (HVOF. The parameter of process and the type of stream equipment determine the quality of the obtained structure and thermal stress in the coating. The article presents the relationship between selected parameters of hybrid process and properties of the coatings. The presented technology should be adapted to the actual production of protective coating for machines and construction working in wear conditions.

  10. Refractive neutron lens

    International Nuclear Information System (INIS)

    Petrov, P.V.; Kolchevsky, N.N.

    2013-01-01

    Model of the refractive neutron lens is proposed. System of N lenses acts as one thin lens with a complex refraction index n*. The maximum number N max of individual lenses for 'thick' neutron lens is calculated. Refractive neutron lens properties (resolution, focal depth) as function of resolution factor F 0 =ρbc/μ and depth of field factor dF 0 =λF 0 =λρbc/μ are calculated. It is shown that micro resolution of the refractive neutron optics is far from the wavelength in size and its open possibilities for progress in refractive neutron optics. (authors)

  11. Large depth of focus dynamic micro integral imaging for optical see-through augmented reality display using a focus-tunable lens.

    Science.gov (United States)

    Shen, Xin; Javidi, Bahram

    2018-03-01

    We have developed a three-dimensional (3D) dynamic integral-imaging (InIm)-system-based optical see-through augmented reality display with enhanced depth range of a 3D augmented image. A focus-tunable lens is adopted in the 3D display unit to relay the elemental images with various positions to the micro lens array. Based on resolution priority integral imaging, multiple lenslet image planes are generated to enhance the depth range of the 3D image. The depth range is further increased by utilizing both the real and virtual 3D imaging fields. The 3D reconstructed image and the real-world scene are overlaid using an optical see-through display for augmented reality. The proposed system can significantly enhance the depth range of a 3D reconstructed image with high image quality in the micro InIm unit. This approach provides enhanced functionality for augmented information and adjusts the vergence-accommodation conflict of a traditional augmented reality display.

  12. Fabrication of Nano-Micro Hybrid Structures by Replication and Surface Treatment of Nanowires

    Directory of Open Access Journals (Sweden)

    Yeonho Jeong

    2017-07-01

    Full Text Available Nanowire structures have attracted attention in various fields, since new characteristics could be acquired in minute regions. Especially, Anodic Aluminum Oxide (AAO is widely used in the fabrication of nanostructures, which has many nanosized pores and well-organized nano pattern. Using AAO as a template for replication, nanowires with a very high aspect ratio can be fabricated. Herein, we propose a facile method to fabricate a nano-micro hybrid structure using nanowires replicated from AAO, and surface treatment. A polymer resin was coated between Polyethylene terephthalate (PET and the AAO filter, roller pressed, and UV-cured. After the removal of aluminum by using NaOH solution, the nanowires aggregated to form a micropattern. The resulting structure was subjected to various surface treatments to investigate the surface behavior and wettability. As opposed to reported data, UV-ozone treatment can enhance surface hydrophobicity because the UV energy affects the nanowire surface, thus altering the shape of the aggregated nanowires. The hydrophobicity of the surface could be further improved by octadecyltrichlorosilane (OTS coating immediately after UV-ozone treatment. We thus demonstrated that the nano-micro hybrid structure could be formed in the middle of nanowire replication, and then, the shape and surface characteristics could be controlled by surface treatment.

  13. Hybrid discrete PSO and OPF approach for optimization of biomass fueled micro-scale energy system

    International Nuclear Information System (INIS)

    Gómez-González, M.; López, A.; Jurado, F.

    2013-01-01

    Highlights: ► Method to determine the optimal location and size of biomass power plants. ► The proposed approach is a hybrid of PSO algorithm and optimal power flow. ► Comparison among the proposed algorithm and other methods. ► Computational costs are enough lower than that required for exhaustive search. - Abstract: This paper addresses generation of electricity in the specific aspect of finding the best location and sizing of biomass fueled gas micro-turbine power plants, taking into account the variables involved in the problem, such as the local distribution of biomass resources, biomass transportation and extraction costs, operation and maintenance costs, power losses costs, network operation costs, and technical constraints. In this paper a hybrid method is introduced employing discrete particle swarm optimization and optimal power flow. The approach can be applied to search the best sites and capacities to connect biomass fueled gas micro-turbine power systems in a distribution network among a large number of potential combinations and considering the technical constraints of the network. A fair comparison among the proposed algorithm and other methods is performed.

  14. Microstructural evolution and mechanical properties of Mg composites containing nano-B4C hybridized micro-Ti particulates

    International Nuclear Information System (INIS)

    Sankaranarayanan, S.; Sabat, R.K.; Jayalakshmi, S.; Suwas, S.; Gupta, M.

    2014-01-01

    In this work, the microstructural evolution and mechanical properties of extruded Mg composites containing micro-Ti particulates hybridized with varying contents of nano-B 4 C are investigated, and compared with Mg-5.6Ti. Microstructural characterization showed the presence of uniformly distributed micro-Ti particles embedded with nano-B 4 C particulates that resulted in significant grain refinement. Electron back scattered diffraction (EBSD) analyses of Mg-(5.6Ti + x-B 4 C) BM hybrid composites showed that the addition of hybridized particle resulted in relatively more recrystallized grains, realignment of basal planes and extension of weak basal fibre texture when compared to Mg-5.6Ti. The evaluation of mechanical properties indicated improved strength with ductility retention in Mg-(5.6Ti + x-B 4 C) BM hybrid composites. When compared to Mg-5.6Ti, the superior strength properties of the Mg-(5.6Ti + x-B 4 C) BM hybrid composites are attributed to the presence of nano-reinforcements, the uniform distribution of the hybridized particles, better interfacial bonding between the matrix and the reinforcement particles and the matrix grain refinement achieved by nano-B 4 C addition. The ductility enhancement obtained in hybrid composites can be attributed to the fibre texture spread and favourable basal plane orientation achieved due to nano B 4 C addition. - Highlights: • Micro-Ti particulates are hybridized with varying weight fractions of nano-B 4 C. • The hybrid mixture was used as hybrid reinforcements in magnesium. • Microstructure and mechanical properties of Mg-(5.6Ti + x-B 4 C) BM are compared with Mg-5.6Ti. • Electron back scattered diffraction (EBSD) analysis conducted to study the microtexture evolution

  15. Lead-acid batteries in micro-hybrid applications. Part I. Selected key parameters

    Science.gov (United States)

    Schaeck, S.; Stoermer, A. O.; Kaiser, F.; Koehler, L.; Albers, J.; Kabza, H.

    Micro-hybrid electric vehicles were launched by BMW in March 2007. These are equipped with brake energy regeneration (BER) and the automatic start and stop function (ASSF) of the internal combustion engine. These functions are based on common 14 V series components and lead-acid (LA) batteries. The novelty is given by the intelligent onboard energy management, which upgrades the conventional electric system to the micro-hybrid power system (MHPS). In part I of this publication the key factors for the operation of LA batteries in the MHPS are discussed. Especially for BER one is high dynamic charge acceptance (DCA) for effective boost charging. Vehicle rest time is identified as a particular negative parameter for DCA. It can be refreshed by regular fully charging at elevated charge voltage. Thus, the batteries have to be outstandingly robust against overcharge and water loss. This can be accomplished for valve-regulated lead-acid (VRLA) batteries at least if they are mounted in the trunk. ASSF goes along with frequent high-rate loads for warm cranking. The internal resistance determines the drop of the power net voltage during cranking and is preferably low for reasons of power net stability even after years of operation. Investigations have to be done with aged 90 Ah VRLA-absorbent glass mat (AGM) batteries. Battery operation at partial state-of-charge gives a higher risk of deep discharging (overdischarging). Subsequent re-charging then is likely to lead to the formation of micro-short circuits in the absorbent glass mat separator.

  16. The potential of hybrid micro-vortex generators to control flow separation of NACA 4415 airfoil in subsonic flow

    Science.gov (United States)

    Jumahadi, Muhammad Taufiq; Saad, Mohd Rashdan; Idris, Azam Che; Sujipto, Suriyadi; Rahman, Mohd Rosdzimin Abdul

    2018-02-01

    Boundary layer separation is detrimental to the lift and drag of most aeronautical applications. Many vortex generators (VG), both passive and active have been designed to reduce these drawbacks. This study targets to investigate the effectiveness of hybrid micro-VGs, which combine both active and passive micro-VGs in controlling separation under subsonic conditions. NACA 4415 airfoils installed with passive, active and hybrid micro-VGs each are designed, 3D printed, and tested in a wind tunnel at 26.19 m/s under Re = 2.5x105. The lift and drag measurements from a 3-component force balance prove that hybrid micro-VGs increase lift by up to 21.2%, increase drag by more than 11.3% and improve lift-to-drag ratio by at least 8.6% until up to 33.7%. From this research, it is believed that hybrid micro-VGs are competitive to the performance of active VGs and a better configuration is to be considered to reduce parasitic drag and outstand active VGs.

  17. Synthesis and characterization of cds-p (nipam-co-maa) hybrid micro gels

    International Nuclear Information System (INIS)

    Khan, M.S.; Khan, G.T.; Khan, A.

    2014-01-01

    Copolymer containing both pH and thermo sensitive properties are very much interesting due to their broad nature to various stimuli. Further, the incorporation of inorganic nanoparticles into stimuli responsive copolymers enhances their utility in different applied nature properties. In the present work such an attempt is made to synthesize copolymer of N-isopropyl acrylamide (NIPAM) and Methacrylic acid (MAA) with CdS nanoparticles. The copolymer of N-isopropyl acrylamide (NIPAM) and Methacrylic acid (MAA) was prepared through emulsion polymerization technique with various compositions and characterized by Fourier transform infrared spectroscopy (FTIR). The microspheres thus prepared were employed as micro-reactors for the deposition of semiconductor cadmium sulfide (CdS) nanoparticles. The obtained composite was characterized using optical, structural and thermal techniques. The micro gels were found to be stable up to 200 degree C. The crystal structure and grain size of Cadmium sulfide-poly (isopropylacrylamide-co-methacrylic acid) (CdS-P(NIPAM-co-MAA)) hybrid micro gels was studied by using X - ray Diffraction. UV Visible spectroscopy and photoluminescence spectroscopy was engaged to get the optical properties of the samples. It was found that the synthesized nanoparticles have a blue shift (higher energy) at about 360 nm which may be due to the typical quantum confinement effects. (author)

  18. Performance of hybrid nano-micro reinforced mg metal matrix composites brake calliper: simulation approach

    Science.gov (United States)

    Fatchurrohman, N.; Chia, S. T.

    2017-10-01

    Most commercial vehicles use brake calliper made of grey cast iron (GCI) which possesses heavy weight. This contributes to the total weight of the vehicle which can lead to higher fuel consumption. Another major problem is GCI calliper tends to deflect during clamping action, known as “bending of bridge”. This will result in extended pedal travel. Magnesium metal matrix composites (Mg-MMC) has a potential application in the automotive industry since it having a lower density, higher strength and very good modulus of elasticity as compared to GCI. This paper proposed initial development of hybrid Mg-MMC brake calliper. This was achieved by analyzing the performance of hybrid nano-micro reinforced Mg-MMC and comparing with the conventional GCI brake calliper. It was performed using simulation in ANSYS, a finite element analysis (FEA) software. The results show that hybrid Mg-MMC has better performance in terms of reduction the weight of the brake calliper, reduction in total deformation/deflection and better ability to withstand equivalent elastic strain.

  19. Plasma assisted fabrication of multi-layer graphene/nickel hybrid film as enhanced micro-supercapacitor electrodes

    Science.gov (United States)

    Ding, Q.; Li, W. L.; Zhao, W. L.; Wang, J. Y.; Xing, Y. P.; Li, X.; Xue, T.; Qi, W.; Zhang, K. L.; Yang, Z. C.; Zhao, J. S.

    2017-03-01

    A facile synthesis strategy has been developed for fabricating multi-layer graphene/nickel hybrid film as micro-supercapacitor electrodes by using plasma enhanced chemical vapor deposition. The as-presented method is advantageous for rapid graphene growth at relatively low temperature of 650 °C. In addition, after pre-treating for the as-deposited nickel film by using argon plasma bombardment, the surface-to-volume ratio of graphene film on the treated nickel substrate is effectively increased by the increasing of surface roughness. This is demonstrated by the characterization results from transmission electron microscopy, scanning electron microscope and atomic force microscopy. Moreover, the electrochemical performance of the resultant graphene/nickel hybrid film as micro-supercapacitor working electrode was investigated by cyclic voltammetry and galvanostatic charge/discharge measurements. It was found that the increase of the surface-to-volume ratio of graphene/nickel hybrid film improved the specific capacitance of 10 times as the working electrode of micro-supercapacitor. Finally, by using comb columnar shadow mask pattern, the micro-supercapacitor full cell device was fabricated. The electrochemical performance measurements of the micro-supercapacitor devices indicate that the method presented in this study provides an effective way to fabricate micro-supercapacitor device with enhanced energy storage property.

  20. An Efficient Hybrid DSMC/MD Algorithm for Accurate Modeling of Micro Gas Flows

    KAUST Repository

    Liang, Tengfei

    2013-01-01

    Aiming at simulating micro gas flows with accurate boundary conditions, an efficient hybrid algorithmis developed by combining themolecular dynamics (MD) method with the direct simulationMonte Carlo (DSMC)method. The efficiency comes from the fact that theMD method is applied only within the gas-wall interaction layer, characterized by the cut-off distance of the gas-solid interaction potential, to resolve accurately the gas-wall interaction process, while the DSMC method is employed in the remaining portion of the flow field to efficiently simulate rarefied gas transport outside the gas-wall interaction layer. A unique feature about the present scheme is that the coupling between the two methods is realized by matching the molecular velocity distribution function at the DSMC/MD interface, hence there is no need for one-toone mapping between a MD gas molecule and a DSMC simulation particle. Further improvement in efficiency is achieved by taking advantage of gas rarefaction inside the gas-wall interaction layer and by employing the "smart-wall model" proposed by Barisik et al. The developed hybrid algorithm is validated on two classical benchmarks namely 1-D Fourier thermal problem and Couette shear flow problem. Both the accuracy and efficiency of the hybrid algorithm are discussed. As an application, the hybrid algorithm is employed to simulate thermal transpiration coefficient in the free-molecule regime for a system with atomically smooth surface. Result is utilized to validate the coefficients calculated from the pure DSMC simulation with Maxwell and Cercignani-Lampis gas-wall interaction models. ©c 2014 Global-Science Press.

  1. Hybrid Solid Oxide Fuel Cell and Thermoelectric Generator for Maximum Power Output in Micro-CHP Systems

    DEFF Research Database (Denmark)

    Rosendahl, Lasse; Mortensen, Paw Vestergård; Enkeshafi, Ali A.

    2011-01-01

    and market segments which are not yet quantified. This paper quantifies a micro-CHP system based on a solid oxide fuel cell (SOFC) and a high-performance TE generator. Based on a 3 kW fuel input, the hybrid SOFC implementation boosts electrical output from 945 W to 1085 W, with 1794 W available for heating...... the electricity production in micro-CHP systems by more than 15%, corresponding to system electrical efficiency increases of some 4 to 5 percentage points. This will make fuel cell-based micro-CHP systems very competitive and profitable and will also open opportunities in a number of other potential business...

  2. Consistent electrification of the powertrain in Mercedes-Benz cars. From micro hybrid to plug-in; Konsequente Elektrifizierung des Antriebsstrangs bei Mercedes-Benz Cars. Vom Micro-Hybrid bis zum Plug-In

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, M.; Henning, G.; Lamm, A.; Bitsche, O.; Antony, P.; Nietfeld, F. [Daimler AG (Germany)

    2010-07-01

    Electrifying vehicle drives is a major part of Daimler's strategy to realize sustained mobility. Electrification encompasses a wide range of concepts and system designs - from the micro hybrid to the plug-in. Economically priced micro hybrids were initially available in the smart fortwo as well as A-Class and B-Class model series and will be successively offered for other model series. Mild and full hybrids, which feature additional functionality, have already been successfully launched or will be available in the near future. The effort to continually advance innovative drive technology culminates in the SClass Plug-In. The lithium-ion battery plays a key role with its high energy density and efficiency. These vehicles and the drive technology they incorporate make it possible to meet the most stringent emissions standards as well as achieve very low fuel economy and CO{sub 2} emissions. (orig.)

  3. Randomized controlled split-mouth clinical trial of direct laminate veneers with two micro-hybrid resin composites

    NARCIS (Netherlands)

    Gresnigt, Marco M. M.; Kalk, Warner; Ozcan, M.; Ozcan, Mutlu

    Objectives: This randomized, split-mouth clinical study evaluated the survival rate of direct laminate veneers made of two resin-composite materials. Methods: A total of 23 patients (mean age: 52.4 years old) received 96 direct composite laminate veneers using two micro-hybrid composites in

  4. Research on Control Strategy of the Micro Grid’s Hybrid Energy System

    Science.gov (United States)

    Gao, Zi-jun; Li, Yang; Wang, Yan-ping; Zong, Ke-yong; Zhang, Jing

    2018-03-01

    This paper study the structure and operating characteristic of the hybrid energy system which is made of super-capacitor and battery. The system is controlled by strategy of bus voltage following. The bus voltage can change the state from swings to stable quickly when load mutation occurs in the micro grid. The transient impact also can be reduced by this way. The passage set up the model of energy system and make an analysis by the software named MATLAB/Simulink. At last, the passage proves the correctness and the effectiveness of the control strategy and draws a conclusion that the transient impact can be inhibited which occurs in the bus voltage of energy system.

  5. Lead-acid batteries in micro-hybrid applications. Part II. Test proposal

    Energy Technology Data Exchange (ETDEWEB)

    Schaeck, S.; Stoermer, A.O. [BMW Group, 80788 Muenchen (Germany); Albers, J. [Johnson Controls Power Solutions EMEA, 30419 Hannover (Germany); Weirather-Koestner, D. [ZSW Ulm, 89081 Ulm (Germany); Kabza, H. [Universitaet Ulm, Institut fuer Energiewandlung und -speicherung, 89081 Ulm (Germany)

    2011-02-01

    In the first part of this work selected key parameters for applying lead-acid (LA) batteries in micro-hybrid power systems (MHPS) were investigated. Main results are integrated in an accelerated, comprehensive test proposal presented here. The test proposal aims at a realistic representation of the pSoC operation regime, which is described in Refs. The test is designed to be sensitive with respect to dynamic charge acceptance (DCA) at partially discharged state (critical for regenerative braking) and the internal resistance at high-rate discharge (critical for idling stop applications). First results are presented for up-to-date valve-regulated LA batteries with absorbent glass mat (AGM) separators. The batteries are close to the limits of the first proposal of pass/fail-criteria. Also flooded batteries were tested; the first out of ten units failed already. (author)

  6. MicroRNA Detection by Whole-Mount In Situ Hybridization in C. elegans.

    Science.gov (United States)

    Andachi, Yoshiki; Kohara, Yuji

    2018-01-01

    MicroRNAs (miRNAs) loaded on argonaute proteins guide RNA-induced silencing complexes to target mRNAs. An excellent method to decipher the spatiotemporal expression patterns of miRNAs is whole-mount in situ hybridization (WISH), which has been successfully used in vertebrate embryos but still remains unavailable for many animal species. Here, we describe a WISH method for miRNA detection in Caenorhabditis elegans at both embryonic and post-embryonic stages. Strategies devised for detection include fixation of animals with carbodiimide at a high temperature and subsequent partial digestion of the fixed animals with an extremely high concentration of proteinase. WISH signals are visualized by staining with a chromogenic substrate or a fluorescent dye.

  7. Lead-acid batteries in micro-hybrid applications. Part II. Test proposal

    Science.gov (United States)

    Schaeck, S.; Stoermer, A. O.; Albers, J.; Weirather-Koestner, D.; Kabza, H.

    In the first part of this work [1] selected key parameters for applying lead-acid (LA) batteries in micro-hybrid power systems (MHPS) were investigated. Main results are integrated in an accelerated, comprehensive test proposal presented here. The test proposal aims at a realistic representation of the pSoC operation regime, which is described in Refs. [1,6]. The test is designed to be sensitive with respect to dynamic charge acceptance (DCA) at partially discharged state (critical for regenerative braking) and the internal resistance at high-rate discharge (critical for idling stop applications). First results are presented for up-to-date valve-regulated LA batteries with absorbent glass mat (AGM) separators. The batteries are close to the limits of the first proposal of pass/fail-criteria. Also flooded batteries were tested; the first out of ten units failed already.

  8. TiO2 micro-nano-hybrid surface to alleviate biological aging of UV-photofunctionalized titanium.

    Science.gov (United States)

    Iwasa, Fuminori; Tsukimura, Naoki; Sugita, Yoshihiko; Kanuru, Rajita Kodali; Kubo, Katsutoshi; Hasnain, Hafiz; Att, Wael; Ogawa, Takahiro

    2011-01-01

    Bioactivity and osteoconductivity of titanium degrade over time after surface processing. This time-dependent degradation is substantial and defined as the biological aging of titanium. UV treatment has shown to reactivate the aged surfaces, a process known as photofunctionalization. This study determined whether there is a difference in the behavior of biological aging for titanium with micro-nano-hybrid topography and titanium with microtopography alone, following functionalization. Titanium disks were acid etched to create micropits on the surface. Micro-nano-hybrid surfaces were created by depositioning 300-nm diameter TiO(2) nodules onto the micropits using a previously established self-assembly protocol. These disks were stored for 8 weeks in the dark to allow sufficient aging, then treated with UV light for 48 hours. Rat bone marrow-derived osteoblasts were cultured on fresh disks (immediately after UV treatment), 3-day-old disks (disks stored for 3 days after UV treatment), and 7-day- old disks. The rates of cell attachment, spread, proliferation, and levels of alkaline phosphatase activity, and calcium deposition were reduced by 30%-50% on micropit surfaces, depending on the age of the titanium. In contrast, 7-day-old hybrid surfaces maintained equivalent levels of bioactivity compared with the fresh surfaces. Both micropit and micro-nano-hybrid surfaces were superhydrophilic immediately after UV treatment. However, after 7 days, the micro-nano- hybrid surfaces became hydrorepellent, while the micropit surfaces remained hydrophilic. The sustained bioactivity levels of the micro-nano-hybrid surfaces were nullified by treating these surfaces with Cl(-)anions. A thin TiO(2) coating on the micropit surface without the formation of nanonodules did not result in the prevention or alleviation of the time-dependent decrease in biological activity. In conclusion, the micro-nano-hybrid titanium surfaces may slow the rate of time-dependent degradation of titanium

  9. Efficient capture of CO2 over ordered micro-mesoporous hybrid carbon nanosphere

    Science.gov (United States)

    Chen, Changwei; Yu, Yanke; He, Chi; Wang, Li; Huang, Huang; Albilali, Reem; Cheng, Jie; Hao, Zhengping

    2018-05-01

    Four kinds of carbon-based adsorbents (micro-mesoporous hybrid carbon nanosphere and N-doped hollow carbon sphere with single-, double- or ruga-shell morphology) with different structural and textural properties were prepared and systematically studied in CO2 capture. All synthesized samples possess high specific surface area (828-910 m2 g-1), large pore volume (0.71-1.81 cm3 g-1), and different micropore contents varied from 2.1% to 46.4%. Amongst, the ordered micro-mesoporous carbon nanosphere (OM-CNS) exhibits the best adsorption performance with CO2 uptake as high as 3.01 mmol g-1 under conditions of 298 K and 1.0 bar, better than most of the reported CO2 adsorbents. The excellent CO2 adsorption capacity of OM-CNS can be reasonably attributed to the synergistic effect of ordered mesopore channels and abundant structural micropores which are beneficial for the diffusion and trapping of CO2 adsorbate. Moreover, the OM-CNS shows excellent CO2 trapping selectivity and superior stability and recyclability, which endow the OM-CNS as a promising and environmental-friendly adsorbent for CO2 capture and separation under practical conditions.

  10. Navigation Aiding by a Hybrid Laser-Camera Motion Estimator for Micro Aerial Vehicles.

    Science.gov (United States)

    Atman, Jamal; Popp, Manuel; Ruppelt, Jan; Trommer, Gert F

    2016-09-16

    Micro Air Vehicles (MAVs) equipped with various sensors are able to carry out autonomous flights. However, the self-localization of autonomous agents is mostly dependent on Global Navigation Satellite Systems (GNSS). In order to provide an accurate navigation solution in absence of GNSS signals, this article presents a hybrid sensor. The hybrid sensor is a deep integration of a monocular camera and a 2D laser rangefinder so that the motion of the MAV is estimated. This realization is expected to be more flexible in terms of environments compared to laser-scan-matching approaches. The estimated ego-motion is then integrated in the MAV's navigation system. However, first, the knowledge about the pose between both sensors is obtained by proposing an improved calibration method. For both calibration and ego-motion estimation, 3D-to-2D correspondences are used and the Perspective-3-Point (P3P) problem is solved. Moreover, the covariance estimation of the relative motion is presented. The experiments show very accurate calibration and navigation results.

  11. Navigation Aiding by a Hybrid Laser-Camera Motion Estimator for Micro Aerial Vehicles

    Directory of Open Access Journals (Sweden)

    Jamal Atman

    2016-09-01

    Full Text Available Micro Air Vehicles (MAVs equipped with various sensors are able to carry out autonomous flights. However, the self-localization of autonomous agents is mostly dependent on Global Navigation Satellite Systems (GNSS. In order to provide an accurate navigation solution in absence of GNSS signals, this article presents a hybrid sensor. The hybrid sensor is a deep integration of a monocular camera and a 2D laser rangefinder so that the motion of the MAV is estimated. This realization is expected to be more flexible in terms of environments compared to laser-scan-matching approaches. The estimated ego-motion is then integrated in the MAV’s navigation system. However, first, the knowledge about the pose between both sensors is obtained by proposing an improved calibration method. For both calibration and ego-motion estimation, 3D-to-2D correspondences are used and the Perspective-3-Point (P3P problem is solved. Moreover, the covariance estimation of the relative motion is presented. The experiments show very accurate calibration and navigation results.

  12. Multi-Stage Hybrid Rocket Conceptual Design for Micro-Satellites Launch using Genetic Algorithm

    Science.gov (United States)

    Kitagawa, Yosuke; Kitagawa, Koki; Nakamiya, Masaki; Kanazaki, Masahiro; Shimada, Toru

    The multi-objective genetic algorithm (MOGA) is applied to the multi-disciplinary conceptual design problem for a three-stage launch vehicle (LV) with a hybrid rocket engine (HRE). MOGA is an optimization tool used for multi-objective problems. The parallel coordinate plot (PCP), which is a data mining method, is employed in the post-process in MOGA for design knowledge discovery. A rocket that can deliver observing micro-satellites to the sun-synchronous orbit (SSO) is designed. It consists of an oxidizer tank containing liquid oxidizer, a combustion chamber containing solid fuel, a pressurizing tank and a nozzle. The objective functions considered in this study are to minimize the total mass of the rocket and to maximize the ratio of the payload mass to the total mass. To calculate the thrust and the engine size, the regression rate is estimated based on an empirical model for a paraffin (FT-0070) propellant. Several non-dominated solutions are obtained using MOGA, and design knowledge is discovered for the present hybrid rocket design problem using a PCP analysis. As a result, substantial knowledge on the design of an LV with an HRE is obtained for use in space transportation.

  13. Effects of different hierarchical hybrid micro/nanostructure surfaces on implant osseointegration.

    Science.gov (United States)

    Cheng, Bingkun; Niu, Qiang; Cui, Yajun; Jiang, Wei; Zhao, Yunzhuan; Kong, Liang

    2017-06-01

    Hierarchical hybrid micro/nanostructure implant surfaces are considered to better mimic the hierarchical structure of bone and the nanostructures substantively influence osseointegration through managing cell behaviors. To enhance implant osseointegration for further clinical application, we evaluated the material properties and osseointegration effects of hierarchical surfaces with different nano-morphologies, using a rat model. Two representative surface fabrication methods, hydrofluoric (HF) acid etching combined with anodization (HF + AN) or magnetron sputtering (HF + MS), were selected. Sample material properties were evaluated by scanning electron microscopy, atomic force microscopy, X-ray diffraction, X-ray photoemission spectroscopy, and epoxy resin docking tensile test. Implants with different surfaces were inserted into the distal femurs of rats. After 12 weeks, osseointegration was examined by microcomputed tomography (micro-CT), histological, and biomechanical tests. Tensile testing demonstrated high bonding strength at coating/implant in the HF + MS group. Micro-CT revealed increased bone volume/total volume and significantly reduced trabecular separation in HF + MS versus other groups. Histological analysis showed significantly higher HF + MS bone-to-implant contact (74.78 ± 4.40%) versus HF + AN (65.11 ± 5.10%) and machined samples (56.03 ± 3.23%). The maximal HF + MS pull-out force increased by 33.7% versus HF + AN. These results indicated that HF + MS surfaces exhibited superior material property in terms of bonding strength and favorable implant osseointegration compared to other groups. © 2017 Wiley Periodicals, Inc.

  14. Ploidia e fertilidade de pólen em progênies de citros Ploidy and pollen fertility in citrus hybrids

    Directory of Open Access Journals (Sweden)

    Eduardo Cesar Brugnara

    2008-01-01

    Full Text Available Este trabalho foi desenvolvido para estimar a fertilidade do pólen e determinar o nível de ploidia em progênies dos cruzamentos da tangerineira 'Montenegrina' (C. deliciosa Ten. com a tangerineira 'King' (C. nobilis Lour. e com a laranjeira 'Caipira' (C. sinensis (L. Osb.. As plantas, de pés-francos e com idade entre 11 e 12 anos, são mantidas na Estação Experimental Agronômica da Universidade Federal do Rio Grande do Sul, em Eldorado do Sul. Avaliaram-se o nível de ploidia, através da contagem dos cromossomos em células em meiose, e a fertilidade do pólen, por coloração do pólen com carmim propiônico, em 2005 e 2006. Todos os híbridos avaliados são diplóides e a fertilidade de pólen variou de zero a 98%. C27 - híbrido de 'Montenegrina' x 'Caipira' - revelou-se praticamente estéril, e a fertilidade de C21, do mesmo cruzamento, é de 10%. A menor fertilidade observada no cruzamento da 'Montenegrina' x 'King' foi de 42%.This work was performed to estimate pollen fertility and determinate the ploidy level of 11 to 12 years old progenies of crosses of 'Montenegrina' mandarin (Citrus deliciosa Ten. with 'King' mandarin (C. nobilis Lour. and with 'Caipira' sweet orange (C. sinensis (L. Osb. maintained at Estação Experimental Agronômica of UFRGS, in Eldorado do Sul, Brazil. The ploidy level was determined by chromosome countings in meiosis cells and pollen fertility evaluated by staining pollen grains with propionic carmine. All evaluated hybrids are diploid and pollen fertility varied from zero to 98%. C27, a hybrid 'Montenegrina' x 'Caipira', was found is sterile, and C21, from the same cross, showed 10 % fertility. The lowest observed fertility in the progeny 'Montenegrina' x 'King' was 42 %.

  15. Hybrid micro-/nano-particle image velocimetry for 3D3C multi-scale velocity field measurement in microfluidics

    International Nuclear Information System (INIS)

    Min, Young Uk; Kim, Kyung Chun

    2011-01-01

    The conventional two-dimensional (2D) micro-particle image velocimetry (micro-PIV) technique has inherent bias error due to the depth of focus along the optical axis to measure the velocity field near the wall of a microfluidics device. However, the far-field measurement of velocity vectors yields good accuracy for micro-scale flows. Nano-PIV using the evanescent wave of total internal reflection fluorescence microscopy can measure near-field velocity vectors within a distance of around 200 nm from the solid surface. A micro-/nano-hybrid PIV system is proposed to measure both near- and far-field velocity vectors simultaneously in microfluidics. A near-field particle image can be obtained by total internal reflection fluorescence microscopy using nanoparticles, and the far-field velocity vectors are measured by three-hole defocusing micro-particle tracking velocimetry (micro-PTV) using micro-particles. In order to identify near- and far-field particle images, lasers of different wavelengths are adopted and tested in a straight microchannel for acquiring the three-dimensional three-component velocity field. We found that the new technique gives superior accuracy for the velocity profile near the wall compared to that of conventional nano-PIV. This method has been successfully applied to precisely measure wall shear stress in 2D microscale Poiseulle flows

  16. Prospects of solar photovoltaic–micro-wind based hybrid power systems in western Himalayan state of Himachal Pradesh in India

    International Nuclear Information System (INIS)

    Sinha, Sunanda; Chandel, S.S.

    2015-01-01

    Highlights: • Good prospects of PV–wind hybrid systems are found in western Himalayan Indian state. • A 6 kWp roof mounted PV–micro wind hybrid system at Hamirpur location is studied. • Optimum PV–wind hybrid system configurations are determined for 12 locations in the region. • Comparative analysis of hybrid systems is carried out using ANN, NASA and measured data. • Methodology can be used for assessing the potential of hybrid power systems worldwide. - Abstract: The western Himalayan state of Himachal Pradesh is known as the hydro-power state of India with associated social and environmental problems of large hydro power plants. The reduced water inflow in the rivers during extreme winters affects power generation in the state. Therefore solar and wind resources need to be utilized to supplement power generation requirements. With this objective the prospects of photovoltaic–micro wind based hybrid systems are studied for 12 locations of the state. The NASA data, Artificial Neural Network predicted and ground measured data are used in the analysis of Hamirpur location whereas for remaining 11 locations estimated, NASA and Artificial Neural Network predicted data are used, as measured solar and wind data are not available for most of the locations in the state. Root Mean Square Error between three input data types are found to range from 0.08 to 1.89. The results show that ANN predicted data are close to measured/estimated data. A 6 kWp roof mounted photovoltaic–micro wind hybrid system at Hamirpur with daily average energy demand of 5.2 kWh/day is studied. This system specifications are used to obtain optimum PV–micro wind based hybrid power system configurations for all locations. The optimum configuration for Hamirpur is found to be a 5 kWp micro wind turbine, 2 kW converter, 10 batteries and 8 kWp PV system whereas for other 11 locations a 5 kWp micro wind turbine, 2 kW converter, 10 batteries and 2–9 kWp PV systems are obtained. The

  17. A whole-mount in situ hybridization method for microRNA detection in Caenorhabditis elegans.

    Science.gov (United States)

    Andachi, Yoshiki; Kohara, Yuji

    2016-07-01

    Whole-mount in situ hybridization (WISH) is an outstanding method to decipher the spatiotemporal expression patterns of microRNAs (miRNAs) and provides important clues for elucidating their functions. The first WISH method for miRNA detection was developed in zebrafish. Although this method was quickly adapted for other vertebrates and fruit flies, WISH analysis has not been successfully used to detect miRNAs in Caenorhabditis elegans Here, we show a novel WISH method for miRNA detection in C. elegans Using this method, mir-1 miRNA was detected in the body-wall muscle where the expression and roles of mir-1 miRNA have been previously elucidated. Application of the method to let-7 family miRNAs, let-7, mir-48, mir-84, and mir-241, revealed their distinct but partially overlapping expression patterns, indicating that miRNAs sharing a short common sequence were distinguishably detected. In pash-1 mutants that were depleted of mature miRNAs, signals of mir-48 miRNA were greatly reduced, suggesting that mature miRNAs were detected by the method. These results demonstrate the validity of WISH to detect mature miRNAs in C. elegans. © 2016 Andachi and Kohara; Published by Cold Spring Harbor Laboratory Press for the RNA Society.

  18. Hybrid setup for micro- and nano-computed tomography in the hard X-ray range

    Science.gov (United States)

    Fella, Christian; Balles, Andreas; Hanke, Randolf; Last, Arndt; Zabler, Simon

    2017-12-01

    With increasing miniaturization in industry and medical technology, non-destructive testing techniques are an area of ever-increasing importance. In this framework, X-ray microscopy offers an efficient tool for the analysis, understanding, and quality assurance of microscopic samples, in particular as it allows reconstructing three-dimensional data sets of the whole sample's volume via computed tomography (CT). The following article describes a compact X-ray microscope in the hard X-ray regime around 9 keV, based on a highly brilliant liquid-metal-jet source. In comparison to commercially available instruments, it is a hybrid that works in two different modes. The first one is a micro-CT mode without optics, which uses a high-resolution detector to allow scans of samples in the millimeter range with a resolution of 1 μm. The second mode is a microscope, which contains an X-ray optical element to magnify the sample and allows resolving 150 nm features. Changing between the modes is possible without moving the sample. Thus, the instrument represents an important step towards establishing high-resolution laboratory-based multi-mode X-ray microscopy as a standard investigation method.

  19. Development of carboxymethyl cellulose-chitosan hybrid micro- and macroparticles for encapsulation of probiotic bacteria.

    Science.gov (United States)

    Singh, P; Medronho, B; Alves, L; da Silva, G J; Miguel, M G; Lindman, B

    2017-11-01

    Novel carboxymethyl cellulose-chitosan (CMC-Cht) hybrid micro- and macroparticles were successfully prepared in aqueous media either by drop-wise addition or via nozzle-spray methods. The systems were either physically or chemically crosslinked using genipin as the reticulation agent. The macroparticles (ca. 2mm) formed are found to be essentially of the core-shell type, while the microparticles (ca. 5μm) are apparently homogeneous. The crosslinked particles are robust, thermally resistant and less sensitive to pH changes. On the other hand, the physical systems are pH sensitive presenting a remarkable swelling at pH 7.4, while little swelling is observed at pH 2.4. Furthermore, model probiotic bacteria (Lactobacillus rhamnosus GG) was for the first time successfully encapsulated in the CMC-Cht based particles with acceptable viability count. Overall, the systems developed are highly promising for probiotic encapsulation and potential delivery in the intestinal tract with the purpose of modulating gut microbiota and improving human health. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Launch Vehicles Based on Advanced Hybrid Rocket Motors: An Enabling Technology for the Commercial Small and Micro Satellite Planetary Science

    Science.gov (United States)

    Karabeyoglu, Arif; Tuncer, Onur; Inalhan, Gokhan

    2016-07-01

    Mankind is relient on chemical propulsion systems for space access. Nevertheless, this has been a stagnant area in terms of technological development and the technology base has not changed much almost for the past forty years. This poses a vicious circle for launch applications such that high launch costs constrain the demand and low launch freqencies drive costs higher. This also has been a key limiting factor for small and micro satellites that are geared towards planetary science. Rather this be because of the launch frequencies or the costs, the access of small and micro satellites to orbit has been limited. With today's technology it is not possible to escape this circle. However the emergence of cost effective and high performance propulsion systems such as advanced hybrid rockets can decrease launch costs by almost an order or magnitude. This paper briefly introduces the timeline and research challenges that were overcome during the development of advanced hybrid LOX/paraffin based rockets. Experimental studies demonstrated effectiveness of these advanced hybrid rockets which incorporate fast burning parafin based fuels, advanced yet simple internal balistic design and carbon composite winding/fuel casting technology that enables the rocket motor to be built from inside out. A feasibility scenario is studied using these rocket motors as building blocks for a modular launch vehicle capable of delivering micro satellites into low earth orbit. In addition, the building block rocket motor can be used further solar system missions providing the ability to do standalone small and micro satellite missions to planets within the solar system. This enabling technology therefore offers a viable alternative in order to escape the viscous that has plagued the space launch industry and that has limited the small and micro satellite delivery for planetary science.

  1. Synthesis and characterization of hybrid micro/nano-structured NiTi surfaces by a combination of etching and anodizing

    Science.gov (United States)

    Huan, Z.; Fratila-Apachitei, L. E.; Apachitei, I.; Duszczyk, J.

    2014-02-01

    The purpose of this study was to generate hybrid micro/nano-structures on biomedical nickel-titanium alloy (NiTi). To achieve this, NiTi surfaces were firstly electrochemically etched and then anodized in fluoride-containing electrolyte. With the etching process, the NiTi surface was micro-roughened through the formation of micropits uniformly distributed over the entire surface. Following the subsequent anodizing process, self-organized nanotube structures enriched in TiO2 could be superimposed on the etched surface under specific conditions. Furthermore, the anodizing treatment significantly reduced water contact angles and increased the surface free energy compared to the surfaces prior to anodizing. The results of this study show for the first time that it is possible to create hybrid micro/nano-structures on biomedical NiTi alloys by combining electrochemical etching and anodizing under controlled conditions. These novel structures are expected to significantly enhance the surface biofunctionality of the material when compared to conventional implant devices with either micro- or nano-structured surfaces.

  2. Synthesis and characterization of hybrid micro/nano-structured NiTi surfaces by a combination of etching and anodizing

    International Nuclear Information System (INIS)

    Huan, Z; Fratila-Apachitei, L E; Apachitei, I; Duszczyk, J

    2014-01-01

    The purpose of this study was to generate hybrid micro/nano-structures on biomedical nickel–titanium alloy (NiTi). To achieve this, NiTi surfaces were firstly electrochemically etched and then anodized in fluoride-containing electrolyte. With the etching process, the NiTi surface was micro-roughened through the formation of micropits uniformly distributed over the entire surface. Following the subsequent anodizing process, self-organized nanotube structures enriched in TiO 2 could be superimposed on the etched surface under specific conditions. Furthermore, the anodizing treatment significantly reduced water contact angles and increased the surface free energy compared to the surfaces prior to anodizing. The results of this study show for the first time that it is possible to create hybrid micro/nano-structures on biomedical NiTi alloys by combining electrochemical etching and anodizing under controlled conditions. These novel structures are expected to significantly enhance the surface biofunctionality of the material when compared to conventional implant devices with either micro- or nano-structured surfaces. (paper)

  3. Synthesis and characterization of hybrid micro/nano-structured NiTi surfaces by a combination of etching and anodizing.

    Science.gov (United States)

    Huan, Z; Fratila-Apachitei, L E; Apachitei, I; Duszczyk, J

    2014-02-07

    The purpose of this study was to generate hybrid micro/nano-structures on biomedical nickel-titanium alloy (NiTi). To achieve this, NiTi surfaces were firstly electrochemically etched and then anodized in fluoride-containing electrolyte. With the etching process, the NiTi surface was micro-roughened through the formation of micropits uniformly distributed over the entire surface. Following the subsequent anodizing process, self-organized nanotube structures enriched in TiO2 could be superimposed on the etched surface under specific conditions. Furthermore, the anodizing treatment significantly reduced water contact angles and increased the surface free energy compared to the surfaces prior to anodizing. The results of this study show for the first time that it is possible to create hybrid micro/nano-structures on biomedical NiTi alloys by combining electrochemical etching and anodizing under controlled conditions. These novel structures are expected to significantly enhance the surface biofunctionality of the material when compared to conventional implant devices with either micro- or nano-structured surfaces.

  4. Hybrid micro/nanostructural surface offering improved stress distribution and enhanced osseointegration properties of the biomedical titanium implant.

    Science.gov (United States)

    Hou, Ping-Jen; Ou, Keng-Liang; Wang, Chin-Chieh; Huang, Chiung-Fang; Ruslin, Muhammad; Sugiatno, Erwan; Yang, Tzu-Sen; Chou, Hsin-Hua

    2018-03-01

    The aim of the present study was to investigate the surface characteristic, biomechanical behavior, hemocompatibility, bone tissue response and osseointegration of the optimal micro-arc oxidation surface-treated titanium (MST-Ti) dental implant. The surface characteristic, biomechanical behavior and hemocompatibility of the MST-Ti dental implant were performed using scanning electron microscope, finite element method, blood dripping and immersion tests. The mini-pig model was utilized to evaluate the bone tissue response and osseointegration of the MST-Ti dental implant in vivo. Data were analyzed by analysis of variance using the Student's t-test (P ≤ 0.05). The hybrid volcano-like micro/nanoporous structure was formed on the surface of the MST-Ti dental implant. The hybrid volcano-like micro/nanoporous surface played an important role to improve the stress transfer between fixture, cortical bone and cancellous bone for the MST-Ti dental implant. Moreover, the MST-Ti implant was considered to have the outstanding hemocompatibility. In vivo testing results showed that the bone-to-implant contact (BIC) ratio significantly altered as the implant with micro/nanoporous surface. After 12 weeks of implantation, the MST-Ti dental implant group exhibited significantly higher BIC ratio than the untreated dental implant group. In addition, the MST-Ti dental implant group also presented an enhancing osseointegration, particularly in the early stages of bone healing. It can be concluded that the micro-arc oxidation approach induced the formation of micro/nanoporous surface is a promising and reliable alternative surface modification for Ti dental implant applications. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. TiO2 micro-nano-hybrid surface to alleviate biological aging of UV-photofunctionalized titanium

    Directory of Open Access Journals (Sweden)

    Iwasa F

    2011-06-01

    Full Text Available Fuminori Iwasa1, Naoki Tsukimura1, Yoshihiko Sugita1, Rajita Kodali Kanuru1, Katsutoshi Kubo1, Hafiz Hasnain1, Wael Att1,2, Takahiro Ogawa11Laboratory of Bone and Implant Sciences (LBIS, The Weintraub Center for Reconstructive Biotechnology, Division of Advanced Prosthodontics, Biomaterials and Hospital Dentistry, UCLA School of Dentistry, Los Angeles, CA, USA; 2Department of Prosthodontics, Dental School, Albert-Ludwigs University, Freiburg, GermanyAbstract: Bioactivity and osteoconductivity of titanium degrade over time after surface processing. This time-dependent degradation is substantial and defined as the biological aging of titanium. UV treatment has shown to reactivate the aged surfaces, a process known as photofunctionalization. This study determined whether there is a difference in the behavior of biological aging for titanium with micro-nano-hybrid topography and titanium with microtopography alone, following functionalization. Titanium disks were acid etched to create micropits on the surface. Micro-nano-hybrid surfaces were created by depositioning 300-nm diameter TiO2 nodules onto the micropits using a previously established self-assembly protocol. These disks were stored for 8 weeks in the dark to allow sufficient aging, then treated with UV light for 48 hours. Rat bone marrow–derived osteoblasts were cultured on fresh disks (immediately after UV treatment, 3-day-old disks (disks stored for 3 days after UV treatment, and 7-day-old disks. The rates of cell attachment, spread, proliferation, and levels of alkaline phosphatase activity, and calcium deposition were reduced by 30%–50% on micropit surfaces, depending on the age of the titanium. In contrast, 7-day-old hybrid surfaces maintained equivalent levels of bioactivity compared with the fresh surfaces. Both micropit and micro-nano-hybrid surfaces were superhydrophilic immediately after UV treatment. However, after 7 days, the micro-nano-hybrid surfaces became hydrorepellent

  6. Fabrication of a miniature diamond grinding tool using a hybrid process of micro-EDM and co-deposition

    International Nuclear Information System (INIS)

    Chen, Shun-Tong; Lai, Yun-Cheng; Liu, Ching-Chang

    2008-01-01

    A novel miniature diamond grinding tool usable for the precise micro-grinding of miniature parts is presented. A hybrid process that combines 'micro-EDM' with 'precision co-deposition' is proposed. The metal substrate is micro-EDMed to a 50 µm diameter and micro diamonds with 0–2 µm grains are 'electroformed' on the substrate surface, producing a miniature multilayered grinding tool. Nickel and diamond act as binders and cutters, respectively. A partition plate with an array of drilled holes is designed to ensure good convection in the electroforming solution. The dispersion of diamond grains and displacement of nickel ions are noticeably improved. A miniature funnel mould enables the diamond grains to converge towards the cathode to increase their deposition probability on the substrate, thereby improving their distribution on the substrate surface. A micro ZrO 2 ceramic ferrule is finely ground by the developed grinding tool and then yields a surface roughness of R a = 0.085 µm. The proposed approach is applied during the final machining process

  7. Development and Testing of a Green-Propellant Micro-Hybrid Thruster with Electrostatic Ignition

    Science.gov (United States)

    Whitmore, Stephen A.; Judson, Michael D.

    2012-01-01

    , requiring an energy input of 14,850 Joules for catalytic dissociation. The hydrocarbon-seeded micro-hybrid was also adapted as a non-pyrotechnic ignitor for a 900 N (200-lbf) thrust hybrid motor. The motor was successfully ignited 4 consecutive times with no hardware swaps or propellant additions. The amount of ABS seed material that can be fit into the injector cap is the only limit to the number of available repeat firings. This series of tests marks the first time a hybrid motor was ever ignited by other than a solid-propellant pyrotechnic charge or bi-propellant flame ignitor. Nitrous oxide hybrid motors are typically difficult to ignite and usually require multiple solid-propellant charges to initiate combustion, so this nonpyrotechnic ignition is a significant accomplishment. The controlled hydrocarbon-seeding approach is fundamentally different from all other green propellant solutions offered by the aerospace industry. Although the proposed system is more correctly a hybrid technology; the system retains all the simple features of a monopropellant design. To date no optimization study has been performed to identify the best grain geometry for electrostatic ignition. Fortunately, because the grain segments are fabricated using rapid-prototyping technology, changing the grain geometry is as simple as modifying the 3-D printer CAD-file. Vacuum Isp exceeding 270 seconds has been demonstrated (Ref v), a value significantly higher than those offered by competing green monopropellant options. The propellants of choice, N2O/GOX and ABS are 100% non-toxic, non-explosive, and environmentally benign. Because the inert oxidizer and fuel components are mixed only within the combustion chamber, the system retains the inherent safety of a hybrid rocket and can be piggy-backed as a secondary payload with no overall mission risk increase to the primary payload, an excellent characteristic for secondary launch systems.

  8. Fabrication of PLA/CaCO3 hybrid micro-particles as carriers for water-soluble bioactive molecules.

    Science.gov (United States)

    Kudryavtseva, Valeriya L; Zhao, Li; Tverdokhlebov, Sergei I; Sukhorukov, Gleb B

    2017-09-01

    We propose the use of polylactic acid/calcium carbonate (PLA/CaCO 3 ) hybrid micro-particles for achieving improved encapsulation of water-soluble substances. Biodegradable porous CaCO 3 microparticles can be loaded with wide range of bioactive substance. Thus, the formation of hydrophobic polymeric shell on surface of these loaded microparticles results on encapsulation and, hence, sealing internal cargo and preventing their release in aqueous media. In this study, to encapsulate proteins, we explore the solid-in-oil-in-water emulsion method for fabricating core/shell PLA/CaCO 3 systems. We used CaCO 3 particles as a protective core for encapsulated bovine serum albumin, which served as a model protein system. We prepared a PLA coating using dichloromethane as an organic solvent and polyvinyl alcohol as a surfactant for emulsification; in addition, we varied experimental parameters such as surfactant concentration and polymer-to-CaCO 3 ratio to determine their effect on particle-size distribution, encapsulation efficiency and capsule permeability. The results show that the particle size decreased and the size distribution narrowed as the surfactant concentration increased in the external aqueous phase. In addition, when the CaCO 3 /PLA mass ratio dropped below 0.8, the hybrid micro-particles were more likely to resist treatment by ethylenediaminetetraacetic acid and thus retained their bioactive cargos within the polymer-coated micro-particles. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Research on Hybrid Isolation System for Micro-Nano-Fabrication Platform

    Directory of Open Access Journals (Sweden)

    Jie Fu

    2014-06-01

    Full Text Available In order to obtain better vibration suppression effect, this paper designs a semiactive/fully active hybrid isolator by using magnetorheological elastomer (MRE and piezoelectric material. Combined with multimode control scheme, full frequency vibration suppression is achieved. Firstly, series type structure is determined for the hybrid isolator, and the structure of hybrid isolator is designed. Next, the dynamic model of hybrid isolator is derived, the dynamic characteristics measurement for MRE isolator and piezoelectric stack actuator (PSA is established, and parameters such as voltage-displacement coefficient, stiffness and damping constant are identified from the experimental results, respectively. Meanwhile, the switch frequency is determined by experimental results of PSA and MRE isolator. Lastly, influence of the stiffness of MRE, control voltage of PSA, and intermediate mass on hybrid isolator system is analyzed by simulations, and the results show that the hybrid isolator proposed is effective.

  10. A simple way to achieve bioinspired hybrid wettability surface with micro/nanopatterns for efficient fog collection.

    Science.gov (United States)

    Yin, Kai; Du, Haifeng; Dong, Xinran; Wang, Cong; Duan, Ji-An; He, Jun

    2017-10-05

    Fog collection is receiving increasing attention for providing water in semi-arid deserts and inland areas. Inspired by the fog harvesting ability of the hydrophobic-hydrophilic surface of Namib desert beetles, we present a simple, low-cost method to prepare a hybrid superhydrophobic-hydrophilic surface. The surface contains micro/nanopatterns, and is prepared by incorporating femtosecond-laser fabricated polytetrafluoroethylene nanoparticles deposited on superhydrophobic copper mesh with a pristine hydrophilic copper sheet. The as-prepared surface exhibits enhanced fog collection efficiency compared with uniform (super)hydrophobic or (super)hydrophilic surfaces. This enhancement can be tuned by controlling the mesh number, inclination angle, and fabrication structure. Moreover, the surface shows excellent anti-corrosion ability after immersing in 1 M HCl, 1 M NaOH, and 10 wt% NaCl solutions for 2 hours. This work may provide insight into fabricating hybrid superhydrophobic-hydrophilic surfaces for efficient atmospheric water collection.

  11. Design, testing, and performance of a hybrid micro vehicle---The Hopping Rotochute

    Science.gov (United States)

    Beyer, Eric W.

    The Hopping Rotochute is a new hybrid micro vehicle that has been developed to robustly explore environments with rough terrain while minimizing energy consumption over long periods of time. The device consists of a small coaxial rotor system housed inside a lightweight cage. The vehicle traverses an area by intermittently powering a small electric motor which drives the rotor system, allowing the vehicle to hop over obstacles of various shapes and sizes. A movable internal mass controls the direction of travel while the egg-like exterior shape and low mass center allows the vehicle to passively reorient itself to an upright attitude when in contact with the ground. This dissertation presents the design, fabrication, and testing of a radio-controlled Hopping Rotochute prototype as well as an analytical study of the flight performance of the device. The conceptual design iterations are first outlined which were driven by the mission and system requirements assigned to the vehicle. The aerodynamic, mechanical, and electrical design of a prototype is then described, based on the final conceptual design, with particular emphasis on the fundamental trades that must be negotiated for this type of hopping vehicle. The fabrication and testing of this prototype is detailed as well as experimental results obtained from a motion capture system. Basic flight performance of the prototype are reported which demonstrates that the Hopping Rotochute satisfies all appointed system requirements. A dynamic model of the Hopping Rotochute is also developed in this thesis and employed to predict the flight performance of the vehicle. The dynamic model includes aerodynamic loads from the body and rotor system as well as a soft contact model to estimate the forces and moments during ground contact. The experimental methods used to estimate the dynamic model parameters are described while comparisons between measured and simulated motion are presented. Good correlation between these motions

  12. Metering systems and demand-side management models applied to hybrid renewable energy systems in micro-grid configuration

    International Nuclear Information System (INIS)

    Blasques, L.C.M.; Pinho, J.T.

    2012-01-01

    This paper proposes a demand-side management model integrated to a metering system for hybrid renewable energy systems in micro-grid configuration. The proposal is based on the management problems verified in most of this kind of renewable hybrid systems installed in Brazil. The main idea is the implementation of a pre-paid metering system with some control functions that directly act on the consumer demand, restricting the consumption proportionally to the monthly availability of renewable energy. The result is a better distribution of the electricity consumption by month and by consumer, preventing that only one user, with larger purchasing power, consumes all the renewable energy available at some time period. The proportionality between the consumption and the renewable energy's availability has the objective to prevent a lack of energy stored and a high use of the diesel generator-set on months of low renewable potential. This paper also aims to contribute to the Brazilian regulation of renewable energy systems supplying micro-grids. - Highlights: ► Review of the Brazilian electricity regulation for small-scale isolated systems. ► Renewable systems are the most feasible option in several isolated communities. ► One proposal is to guarantee government subsidies for renewable energy systems. ► Smart electronic meters to create electricity restrictions for the consumers.

  13. The Technique of Changing the Drive Method of Micro Step Drive and Sensorless Drive for Hybrid Stepping Motor

    Science.gov (United States)

    Yoneda, Makoto; Dohmeki, Hideo

    The position control system with the advantage large torque, low vibration, and high resolution can be obtained by the constant current micro step drive applied to hybrid stepping motor. However loss is large, in order not to be concerned with load torque but to control current uniformly. As the one technique of a position control system in which high efficiency is realizable, the same sensorless control as a permanent magnet motor is effective. But, it was the purpose that the control method proposed until now controls speed. Then, this paper proposed changing the drive method of micro step drive and sensorless drive. The change of the drive method was verified from the simulation and the experiment. On no load, it was checked not producing change of a large speed at the time of a change by making electrical angle and carrying out zero reset of the integrator. On load, it was checked that a large speed change arose. The proposed system could change drive method by setting up the initial value of an integrator using the estimated result, without producing speed change. With this technique, the low loss position control system, which employed the advantage of the hybrid stepping motor, has been built.

  14. Nano/micro hybrid scaffold of PCL or P3HB nanofibers combined with silk fibroin for tendon and ligament tissue engineering.

    Science.gov (United States)

    Naghashzargar, Elham; Farè, Silvia; Catto, Valentina; Bertoldi, Serena; Semnani, Dariush; Karbasi, Saeed; Tanzi, Maria Cristina

    2015-07-04

    A novel biodegradable nano/micro hybrid structure was obtained by electrospinning P3HB or PCL nanofibers onto a twisted silk fibroin (SF) structure, with the aim of fabricating a suitable scaffold for tendon and ligament tissue engineering. The electrospinning (ES) processing parameters for P3HB and PCL were optimized on 2D samples, and applied to produce two different nano/micro hybrid constructs (SF/ES-PCL and SF/ES-P3HB).Morphological, chemico-physical and mechanical properties of the novel hybrid scaffolds were evaluated by SEM, ATR FT-IR, DSC, tensile and thermodynamic mechanical tests. The results demonstrated that the nanofibers were tightly wrapped around the silk filaments, and the crystallinity of the SF twisted yarns was not influenced by the presence of the electrospun polymers. The slightly higher mechanical properties of the hybrid constructs confirmed an increase of internal forces due to the interaction between nano and micro components. Cell culture tests with L929 fibroblasts, in the presence of the sample eluates or in direct contact with the hybrid structures, showed no cytotoxic effects and a good level of cytocompatibility of the nano/micro hybrid structures in term of cell viability, particularly at day 1. Cell viability onto the nano/micro hybrid structures decreased from the first to the third day of culture when compared with the control culture plastic, but appeared to be higher when compared with the uncoated SF yarns. Although additional in vitro and in vivo tests are needed, the original fabrication method here described appears promising for scaffolds suitable for tendon and ligament tissue engineering.

  15. Hybrid Macro-Micro Fluidics System for a Chip-Based Biosensor

    National Research Council Canada - National Science Library

    Tamanaha, C. R; Whitman, L. J; Colton, R.J

    2002-01-01

    We describe the engineering of a hybrid fluidics platform for a chip-based biosensor system that combines high-performance microfluidics components with powerful, yet compact, millimeter-scale pump and valve actuators...

  16. Performance optimization of a hybrid micro-grid based on double-loop MPPT and SVC-MERS

    Science.gov (United States)

    Wei, Yewen; Hou, Xilun; Zhang, Xiang; Xiong, Shengnan; Peng, Fei

    2018-02-01

    With ever-increasing concerns on environmental pollution and energy shortage, the development of renewable resource has attracted a lot of attention. This paper first reviews both the wind and photovoltaic (PV) generation techniques and approaches of micro-grid voltage control. Then, a novel islanded micro-grid, which consists of wind & PV generation and hybrid-energy storage device, is built for application to remote and isolated areas. For the PV power generation branch, a double- maximum power point tracking (MPPT) technique is developed to trace the sunlight and regulate the tilt angle of PV panels. For wind-power generation branch, squirrel cage induction generator (SCIG) is used as its simple structure, robustness and less cost. In order to stabilize the output voltage of SCIGs, a new Static Var Compensator named magnetic energy recovery switch (SVC-MERS) is applied. Finally, experimental results confirm that both of the proposed methods can improve the efficiency of PV power generation and voltage stability of the micro-grid, respectively.

  17. In situ micro-focused X-ray beam characterization with a lensless camera using a hybrid pixel detector

    International Nuclear Information System (INIS)

    Kachatkou, Anton; Marchal, Julien; Silfhout, Roelof van

    2014-01-01

    Position and size measurements of a micro-focused X-ray beam, using an X-ray beam imaging device based on a lensless camera that collects radiation scattered from a thin foil placed in the path of the beam at an oblique angle, are reported. Results of studies on micro-focused X-ray beam diagnostics using an X-ray beam imaging (XBI) instrument based on the idea of recording radiation scattered from a thin foil of a low-Z material with a lensless camera are reported. The XBI instrument captures magnified images of the scattering region within the foil as illuminated by the incident beam. These images contain information about beam size, beam position and beam intensity that is extracted during dedicated signal processing steps. In this work the use of the device with beams for which the beam size is significantly smaller than that of a single detector pixel is explored. The performance of the XBI device equipped with a state-of-the-art hybrid pixel X-ray imaging sensor is analysed. Compared with traditional methods such as slit edge or wire scanners, the XBI micro-focused beam characterization is significantly faster and does not interfere with on-going experiments. The challenges associated with measuring micrometre-sized beams are described and ways of optimizing the resolution of beam position and size measurements of the XBI instrument are discussed

  18. Evaluation of Eleven Macro and Micro Elements Present in Various Hybrids of Millet (Pennisetum glaucum, or P. Americanum

    Directory of Open Access Journals (Sweden)

    Ghulam Qadir Shar

    2012-06-01

    Full Text Available Maize and Millet Research Institute (MMRI situated in Yousuf wala, District Sahiwal, Punjab, Pakistan was selected to grow nine different hybrids/cultivars of millet for study to comprehend the variable concentration of macro, micro and trace and toxic elements in their grains. Wet digestion method was used for the preparation of samples and flame atomic absorption spectrophotometer for analysis of eleven major and minor elements. High values of macro-elements i.e. sodium and potassium was found in ICMP-451 and magnesium in ICMP-53506. The high value of essential micro-elements i.e.zinc (50mg/kg, manganese (8mg/kg, and copper (8mg/kg was calculated in ICMP-53506, Bullo-94-1, and ICMP-83720 respectively. In case of trace and toxic micro-elements, high concentration of nickel, cobalt, chromium and cadmium was found in O.B.V, Bullo-7704, ICMP-83401, and ICMP-83720 in the edible part of millet plants (grains cultivars respectively.

  19. Evaluation of eleven macro and micro elements present in various hybrids of millet (pennisetum glucum, or P. americanum)

    International Nuclear Information System (INIS)

    Shar, G.Q.; Shar, L.A.

    2012-01-01

    Maize and Millet Research Institute (MMRI) situated in Yousuf wala, District Sahiwal, Punjab, Pakistan was selected to grow nine different hybrids/cultivars of millet for study to comprehend the variable concentration of macro, micro and trace and toxic elements in their grains. Wet digestion method was used for the preparation of samples and flame atomic absorption spectrophotometer for analysis of eleven major and minor elements. High values of macro-elements i.e. sodium and potassium was found in ICMP-45 I and magnesium in ICMP-53506. The high value of essential micro-elements i.e. zinc (50 mg/kg), manganese (8 mg/kg), and copper (8mg/kg) was calculated in ICMP-53506, Bullo-94-1, and ICMP-83120 respectively. In case of trace and toxic micro-elements, high concentration of nickel, cobalt, chromium and cadmium was found in O.B.V, Bullo-1104, ICMP-83401, and ICMP-83120 in the edible part of millet plants (grains) cultivars respectively. (author)

  20. Micro-electro-fluidic grids for nematodes: a lens-less, image-sensor-less approach for on-chip tracking of nematode locomotion.

    Science.gov (United States)

    Liu, Peng; Martin, Richard J; Dong, Liang

    2013-02-21

    This paper reports on the development of a lens-less and image-sensor-less micro-electro-fluidic (MEF) approach for real-time monitoring of the locomotion of microscopic nematodes. The technology showed promise for overcoming the constraint of the limited field of view of conventional optical microscopy, with relatively low cost, good spatial resolution, and high portability. The core of the device was microelectrode grids formed by orthogonally arranging two identical arrays of microelectrode lines. The two microelectrode arrays were spaced by a microfluidic chamber containing a liquid medium of interest. As a nematode (e.g., Caenorhabditis elegans) moved inside the chamber, the invasion of part of its body into some intersection regions between the microelectrodes caused changes in the electrical resistance of these intersection regions. The worm's presence at, or absence from, a detection unit was determined by a comparison between the measured resistance variation of this unit and a pre-defined threshold resistance variation. An electronic readout circuit was designed to address all the detection units and read out their individual electrical resistances. By this means, it was possible to obtain the electrical resistance profile of the whole MEF grid, and thus, the physical pattern of the swimming nematode. We studied the influence of a worm's body on the resistance of an addressed unit. We also investigated how the full-frame scanning and readout rates of the electronic circuit and the dimensions of a detection unit posed an impact on the spatial resolution of the reconstructed images of the nematode. Other important issues, such as the manufacturing-induced initial non-uniformity of the grids and the electrotaxic behaviour of nematodes, were also studied. A drug resistance screening experiment was conducted by using the grids with a good resolution of 30 × 30 μm(2). The phenotypic differences in the locomotion behaviours (e.g., moving speed and oscillation

  1. Birc7: A Late Fiber Gene of the Crystalline Lens.

    Science.gov (United States)

    De Maria, Alicia; Bassnett, Steven

    2015-07-01

    A distinct subset of genes, so-called "late fiber genes," is expressed in cells bordering the central, organelle-free zone (OFZ) of the lens. The purpose of this study was to identify additional members of this group. Fiber cells were harvested from various layers of the lens by laser micro-dissection and subjected to microarray, in situ hybridization, and Western blot analysis. Expression of Livin, a member of the inhibitor of apoptosis protein (IAP) family encoded by Birc7, was strongly upregulated in deep cortical fiber cells. The depth-dependent distribution of Livin mRNA was confirmed by quantitative PCR and in situ hybridization. The onset of Livin expression coincided with loss of organelles from primary fiber cells. Livin expression peaked at 1 month but was sustained even in aged lenses. Antibodies raised against mouse Livin labeled multiple bands on immunoblots, reflecting progressive proteolysis of the parent molecule during differentiation. Mice harboring a floxed Birc7 allele were generated and used to conditionally delete Birc7 in lens. Lenses from knockout mice grew normally and retained their transparency, suggesting that Livin does not have an indispensable role in fiber cell differentiation. Birc7 is a late fiber gene of the mouse lens. In tumor cells, Livin acts as an antiapoptotic protein, but its function in the lens is enigmatic. Livin is a RING domain protein with putative E3 ubiquitin ligase activity. Its expression in cells bordering the OFZ is consistent with a role in organelle degradation, a process in which the ubiquitin proteasome pathway has been implicated previously.

  2. Objective lens

    Science.gov (United States)

    Olczak, Eugene G. (Inventor)

    2011-01-01

    An objective lens and a method for using same. The objective lens has a first end, a second end, and a plurality of optical elements. The optical elements are positioned between the first end and the second end and are at least substantially symmetric about a plane centered between the first end and the second end.

  3. P.I.X.S.C.A.N.: a micro-CT scanner for small animal based on hybrid pixel detectors; PIXSCAN: micro-tomodensitrometre a pixels hybrides pour le petit animal

    Energy Technology Data Exchange (ETDEWEB)

    Khoury, R

    2008-03-15

    Since more than a dozen years, efforts were led in the field of X-ray tomography for small animals, principally for the improvement of spatial resolution and the diminution of the absorbed dose. The C.P.P.M. developed the micro-CT P.I.X.S.C.A.N. based on the hybrid pixel detector X.P.A.D.2. In this context, my thesis work consists in studying the demonstrator P.I.X.S.C.A.N./X.P.A.D.2 and the contribution of the hybrid pixels in the imaging of small animals. A fast analytical simulation, FastSimu, was developed. An extrapolation of the performance of the demonstrator P.I.X.S.C.A.N, as well as the validation of the results obtained with the measured data, were led by means of the analytical simulator FastSimu. The demonstrator P.I.X.S.C.A.N./X.P.A.D.2 allowed to obtain reconstructed images with a rather good quality for a relatively weak absorbed dose. Its spatial resolution is degraded by the high number of defective pixels of the detector X.P.A.D.2. Beyond this study, a new version of the demonstrator P.I.X.S.C.A.N./X.P.A.D.2 is under construction. This latter, characterized by two and a half times smaller pixels and about no defective pixels will bring a considerable improvement on spatial resolution. (author)

  4. Magnetic bead-based hybridization assay for electrochemical detection of microRNA

    Czech Academy of Sciences Publication Activity Database

    Bartošík, Martin; Hrstka, R.; Paleček, Emil; Vojtešek, B.

    2014-01-01

    Roč. 813, FEB2014 (2014), s. 35-40 ISSN 0003-2670 R&D Projects: GA ČR(CZ) GBP206/12/G151; GA ČR(CZ) GA13-00956S Institutional support: RVO:68081707 Keywords : MicroRNA * Electrochemistry * Mercury electrodes Subject RIV: BO - Biophysics Impact factor: 4.513, year: 2014

  5. Thermodynamic Performance Study of Biomass Gasification, Solid Oxide Fuel Cell and Micro Gas Turbine Hybrid Systems

    DEFF Research Database (Denmark)

    Bang-Møller, Christian; Rokni, Masoud

    2010-01-01

    A system level modelling study of three combined heat and power systems based on biomass gasification is presented. Product gas is converted in a micro gas turbine (MGT) in the first system, in a solid oxide fuel cell (SOFC) in the second system and in a combined SOFC–MGT arrangement in the third...

  6. Development of hybrid micro circuit based multi-channel programmable HV supply for BARC-pelletron experimental facility

    International Nuclear Information System (INIS)

    Manna, A.; Thombare, S.; Moitra, S.; Kuswarkar, M.; Punna, M.; Nair, P.M.; Diwakar, M.P.; Pithawa, C.K.

    2013-01-01

    Electronics Division, BARC has developed a Multi channel programmable HV bias supply system for charge particle detector array for use in BARC-TIFR Pelletron-LINAC facility. The HV supplies are compact in size due to use of hybrid micro-circuits developed indigenously and are modular in construction to achieve versatility, scalability and serviceability. All programming operations and monitoring are performed remotely through PC over Ethernet. Each supply has a built-in over voltage, over current and thermal overload protections for safe operation and employs a Zero Voltage Switching (ZVS) technique to reduce thermal stress on the inverter switches. This article describes salient design aspects and performance of the HV supply system. (author)

  7. Energy Management of a Hybrid AC–DC Micro-Grid Based on a Battery Testing System

    Directory of Open Access Journals (Sweden)

    Bo Long

    2015-02-01

    Full Text Available Energy Recovery Battery Testing Systems (ERBTS plays an important role in battery manufacture. The conventional ERBTS configuration contains a fundamental transformer, and a bidirectional Direct Current (DC–DC and Alternating Current (AC–DC converter. All ERBTS are connected in parallel, thus constituting a special and complicated AC micro-grid system. Aiming at addressing their low energy recovery efficiency, complex grid-connected control algorithm issues for islanded detection, and complicated power circuit topology issues, a hierarchical DC-link voltage hybrid AC–DC micro-grid that contains composite energy storing devices is proposed. Moreover, an energy management optimal scheme for the proposed scheme is put forward. The system configuration of the proposed scheme is described in detail. Compared to the conventional scheme, the proposed scheme has the merits of simplified power circuit topology, no need for phase synchronous control, and much higher energy recovery efficiency and reliability. The validity and effectiveness of the proposed technique is verified through numerous experimental results.

  8. Spin coating and plasma process for 2.5D and hybrid 3D micro-resonators on multilayer polymers

    Science.gov (United States)

    Bêche, B.; Gaviot, E.; Godet, C.; Zebda, A.; Potel, A.; Barbe, J.; Camberlein, L.; Vié, V.; Panizza, P.; Loas, G.; Hamel, C.; Zyss, J.; Huby, N.

    2009-05-01

    We have designed and realized three integrated photonic families of micro-resonators (MR) on multilayer organic materials. Such so-called 2.5D-MR and 3D-MR structures show off radius values ranging from 40 to 200μm. Both first and second families are especially designed on organic multilayer materials and shaped as ring- and disk-MR organics structures arranged upon (and coupled with) a pair of SU8-organic waveguides. The third family is related to hybrid 3D-MR structures composed of spherical glass-MR coupled to organic waveguides by a Langmuir-Blodgett lipid film about three nanometers in thickness. At first, polymer spin coating, surface plasma treatment and selective UV-lithography processes have been developed to realize 2.5D photonic micro-resonators. Secondly, we have designed and characterized photonic-quadripoles made of 3D-glass-MR arranged upon a pair of SU8 waveguides. Such structures are defined by a 4-ports or 4-waveguides coupled by the spherical glass-MR. We have achieved an evanescent photonic coupling between the 3D-MR and the 4-ports structure. Spectral resonances have been measured for 4-whispering gallery-modes (WGM) into such 3D-structures respectively characterized by a 0.97 nm free spectral range (FSR) and a high quality Q-factor up to 4.104.

  9. Carbon nanotube-polyamidoamine dendrimer hybrid-modified electrodes for highly sensitive electrochemical detection of microRNA24.

    Science.gov (United States)

    Li, Fengye; Peng, Jing; Zheng, Qiong; Guo, Xiang; Tang, Hao; Yao, Shouzhuo

    2015-01-01

    A simple and ultrasensitive microRNA (miRNA) electrochemical biosensor employing multiwalled carbon nanotube (MWCNT)-polyamidoamine (PAMAM) dendrimer and methylene blue (MB) redox indicator is reported in this work. The assay utilizes a glass carbon (GC) electrode modified with MWCNT-PAMAM, on which the oligonucleotide capture probes are immobilized. The electrochemical detection of miRNAs is completed by measuring the reduction signal change of MB before and after the probe hybridization with target miRNA (miRNA24 is used as a model case). The MWCNT-PAMAM/GC electrode shows greatly enhanced signal to MB reduction in contrast to bare GC electrode. The functionalization of MWCNT with PAMAM maintains the electrochemical property of MWCNT to MB reduction but minimizes the undesired adsorption of MB on the MWCNT surface. The effect of experimental variables on the miRNA detection is investigated and optimized. A detection limit of 0.5 fM and a linear peak current density-concentration relationship up to 100 nM are obtained following 60 min hybridization. The proposed assay is successfully used to detect miRNA24 in total RNA sample extracted from HeLa cells.

  10. Comparative techno-economic analysis of hybrid micro-grid systems utilizing different battery types

    International Nuclear Information System (INIS)

    Ciez, Rebecca E.; Whitacre, J.F.

    2016-01-01

    Highlights: • Comparative analysis of 3 battery chemistries in microgrid storage application. • At discount rates >1%, diesel-only generation still cheapest electricity option. • Optimal battery chemistry highly dependent on discount rate. • For discount rates <4%, lead acid is the cheapest storage options. • High energy density li-ion the cheapest storage option for discount rates >4%. - Abstract: A systems-level lifetime cost-of-use optimization model was applied to a hypothetical hybrid off-grid power system to compare the impacts of different battery technologies. Specifically, a time-step battery degradation model was used to account for unit degradation over a 20-year system lifetime for three different batteries. Variables examined included: battery type, allowed state of charge swing during cycling, number of battery replacements, fractional renewable energy requirements, and applied discount rate. Our analyses show that storage packs with high energy, low cost lithium-ion cells have the potential to compete with a non-renewable solution in some cases. The discount rate also proves to be significant in determining the cost competitiveness of the hybrid systems: at low discount rates, the levelized cost of electricity (LCOE) is only slightly higher than diesel generation, with costs diverging as the discount rate increases. The discount rate also determines which battery technology delivers the lowest cost of electricity: lead acid batteries are favorable at low rates, while high-energy lithium-ion batteries deliver lower cost electricity at higher rates. Similarly, market forces, like fuel or battery price changes, feed-in tariffs, or carbon taxes, required to trigger a switch to a hybrid system vary substantially with the discount rate.

  11. Hybrid micro-GA based FLCs for TCSC and UPFC in a multi-machine environment

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Laiq [GIK Institute Topi, Swabi (Pakistan); Lo, K.L. [University of Strathclyde, Glasgow (United Kingdom)

    2006-06-15

    In this paper, a systematic fuzzy logic based damping control system design for TCSC and UPFC is proposed to enhance the power system stability spectrum. Firstly, the fuzzy membership functions and control rules are extracted based on the recorded or monitored signals. Then, the novel 'Grand-Parenting' technique is employed to incorporate the non-optimal fuzzy logic controllers in micro-GA ({mu}-GA) to search for optimal fuzzy membership functions and rules simultaneously. Simulation studies have been carried out to show the effectiveness and robustness of the proposed damping control strategy in a multi-machine power system setup. (author)

  12. Enzyme-free electrochemical detection of microRNA-21 using immobilized hairpin probes and a target-triggered hybridization chain reaction amplification strategy

    International Nuclear Information System (INIS)

    Liu, Hongying; Bei, Xiaoqiong; Xia, Qiuting; Fu, Yan; Zhang, Shi; Liu, Maochuan; Fan, Kai; Zhang, Mingzhen; Yang, Yong

    2016-01-01

    We describe a sensitive enzyme-free bioassay for the determination of microRNA-21. It is based on a combination of target-triggered hybridization chain reaction, tagging with CdTe quantum dots (QDs), and anodic stripping voltammetry. Firstly, a thiolated capture hairpin probe SH-HP1 was immobilized on the surface of a gold electrode. HP1 unfolds in the presence of microRNA-21. If hairpin probe 2 (HP2) is present, a HP1-HP2 complex will be formed which possesses an exposed stem of HP2, and microRNA is released in parallel. The released microRNA-21 triggers a hybridization chain reaction and this leads to form an exposed DNA segment of HP2 and cycle use microRNA-21. With the aid of assistant DNA A1 and A2, the exposed DNA segment of HP2 progressed to a long double strand. The strand is rich in CdTe QDs with the help of QDs-A1. Then, the attached QDs were dissolved with HNO 3 to give dissolved Cd(II) ions. Finally, the corresponding electrochemical current response of Cd(II) is monitored by anodic stripping voltammetry and used to quantify the concentration of microRNA-21. More microRNA-21 participated in this reaction increases the number of CdTe QDs, which results in increased electrochemical current. Thus, an ultrasensitive detection of microRNA-21 is accomplished by anodic stripping voltammetry. This gene assay displays a detection limit as low as 33 aM. It can discriminate between complementary DNA sequence and single-base mismatched DNA, indicating its high specificity. (author)

  13. Study of Micro Grid Hybrid System of Photovoltaic and Diesel Engine

    Directory of Open Access Journals (Sweden)

    Novitasari Dwi

    2016-01-01

    Full Text Available Indonesia has abundant potentials of new and renewable energy that can be used for electricity generation, especially in rural areas which have no access for grid electricity yet. The energy resources can be from solar, water, biomass or biofuel. Many villagers still use diesel generators to produce electricity in their villages. It is considered expensive because fuel price in rural areas increases 2-3 times than the normal price due to transportation cost. Hybrid system using renewable energy resources is one of the solutions to produce electricity in affordable cost for rural area. The idea is to combine diesel generators and photovoltaic toproduce electricity. Moreover, the diesel engine fuel can be replaced with biofuel. This study will analyze the hybrid system in a small scale which consists of 1kWp photovoltaic and 3 kW diesel engine. Electric load power will vary. The system is controlled by a single bidirectional inverter whichconverts power from DC to AC and vice versa

  14. Hybrid macro-micro fluidics system for a chip-based biosensor

    Science.gov (United States)

    Tamanaha, C. R.; Whitman, L. J.; Colton, R. J.

    2002-03-01

    We describe the engineering of a hybrid fluidics platform for a chip-based biosensor system that combines high-performance microfluidics components with powerful, yet compact, millimeter-scale pump and valve actuators. The microfluidics system includes channels, valveless diffuser-based pumps, and pinch-valves that are cast into a poly(dimethylsiloxane) (PDMS) membrane and packaged along with the sensor chip into a palm-sized plastic cartridge. The microfluidics are driven by pump and valve actuators contained in an external unit (with a volume ~30 cm3) that interfaces kinematically with the PDMS microelements on the cartridge. The pump actuator is a simple-lever, flexure-hinge displacement amplifier that increases the motion of a piezoelectric stack. The valve actuators are an array of cantilevers operated by shape memory alloy wires. All components can be fabricated without the need for complex lithography or micromachining, and can be used with fluids containing micron-sized particulates. Prototypes have been modeled and tested to ensure the delivery of microliter volumes of fluid and the even dispersion of reagents over the chip sensing elements. With this hybrid approach to the fluidics system, the biochemical assay benefits from the many advantages of microfluidics yet we avoid the complexity and unknown reliability of immature microactuator technologies.

  15. Impact of plug-in hybrid electric vehicles charging demand on the optimal energy management of renewable micro-grids

    International Nuclear Information System (INIS)

    Kavousi-Fard, Abdollah; Abunasri, Alireza; Zare, Alireza; Hoseinzadeh, Rasool

    2014-01-01

    This paper suggests a new stochastic expert framework to investigate the charging effect of plug-in hybrid electric vehicles (PHEVs) on the optimal operation and management of micro-grids (MGs). In this way, a useful method based on smart charging approach is proposed to consider the charging demand of PHEVs in both residential location and public charging stations. The analysis is simulated for 24 h considering the uncertainties associated with the forecast error in the charging demand of PHEVs, hourly load consumption, hourly energy price and Renewable Energy Sources (RESs) output power. In order to see the effect of storage devices on the operation of the MG, NiMH-Battery is also incorporated in the MG. According to the high complexity of the problem, a new optimization method called θ-krill herd (θ-KH) algorithm is proposed which uses the phase angle vectors to update the velocity/position of krill animals with faster and more stable convergence. In addition, a new modification method is proposed to improve the search ability of the algorithm, effectively. The suggested problem is examined on an MG including different RESs such as photovoltaic (PV), fuel cells (FCs), wind turbine (WT), micro turbine (MT) and battery as the storage device. - Highlights: • Introducing an expert stochastic framework for optimal operation and management of MGs including PHEVs. • Introducing a new artificial optimization algorithm based on KH evolutionary technique. • Introducing a new version of KH algorithm called θ-KH for the optimization applications. • Modeling the uncertainty of forecast error in Wind turbine, Photovoltaics, market price, load data, PHEVs electric charging demand in an intelligent framework

  16. Lens Model

    DEFF Research Database (Denmark)

    Nash, Ulrik William

    2014-01-01

    Firms consist of people who make decisions to achieve goals. How do these people develop the expectations which underpin the choices they make? The lens model provides one answer to this question. It was developed by cognitive psychologist Egon Brunswik (1952) to illustrate his theory of probabil...

  17. Scalable High-Performance Ultraminiature Graphene Micro-Supercapacitors by a Hybrid Technique Combining Direct Writing and Controllable Microdroplet Transfer.

    Science.gov (United States)

    Shen, Daozhi; Zou, Guisheng; Liu, Lei; Zhao, Wenzheng; Wu, Aiping; Duley, Walter W; Zhou, Y Norman

    2018-02-14

    Miniaturization of energy storage devices can significantly decrease the overall size of electronic systems. However, this miniaturization is limited by the reduction of electrode dimensions and the reproducible transfer of small electrolyte drops. This paper reports first a simple scalable direct writing method for the production of ultraminiature microsupercapacitor (MSC) electrodes, based on femtosecond laser reduced graphene oxide (fsrGO) interlaced pads. These pads, separated by 2 μm spacing, are 100 μm long and 8 μm wide. A second stage involves the accurate transfer of an electrolyte microdroplet on top of each individual electrode, which can avoid any interference of the electrolyte with other electronic components. Abundant in-plane mesopores in fsrGO induced by a fs laser together with ultrashort interelectrode spacing enables MSCs to exhibit a high specific capacitance (6.3 mF cm -2 and 105 F cm -3 ) and ∼100% retention after 1000 cycles. An all graphene resistor-capacitor (RC) filter is also constructed by combining the MSC and a fsrGO resistor, which is confirmed to exhibit highly enhanced performance characteristics. This new hybrid technique combining fs laser direct writing and precise microdroplet transfer easily enables scalable production of ultraminiature MSCs, which is believed to be significant for practical application of micro-supercapacitor microelectronic systems.

  18. Double closed-loop resonant micro optic gyro using hybrid digital phase modulation.

    Science.gov (United States)

    Ma, Huilian; Zhang, Jianjie; Wang, Linglan; Jin, Zhonghe

    2015-06-15

    It is well-known that the closed-loop operation in optical gyros offers wider dynamic range and better linearity. By adding a stair-like digital serrodyne wave to a phase modulator can be used as a frequency shifter. The width of one stair in this stair-like digital serrodyne wave should be set equal to the optical transmission time in the resonator, which is relaxed in the hybrid digital phase modulation (HDPM) scheme. The physical mechanism for this relaxation is firstly indicated in this paper. Detailed theoretical and experimental investigations are presented for the HDPM. Simulation and experimental results show that the width of one stair is not restricted by the optical transmission time, however, it should be optimized according to the rise time of the output of the digital-to-analogue converter. Based on the optimum parameters of the HDPM, a bias stability of 0.05°/s for the integration time of 400 seconds in 1 h has been carried out in an RMOG with a waveguide ring resonator with a length of 7.9 cm and a diameter of 2.5 cm.

  19. Effects of a hybrid micro/nanorod topography-modified titanium implant on adhesion and osteogenic differentiation in rat bone marrow mesenchymal stem cells.

    Science.gov (United States)

    Zhang, Wenjie; Li, Zihui; Huang, Qingfeng; Xu, Ling; Li, Jinhua; Jin, Yuqin; Wang, Guifang; Liu, Xuanyong; Jiang, Xinquan

    2013-01-01

    Various methods have been used to modify titanium implant surfaces with the aim of achieving better osseointegration. In this study, we fabricated a clustered nanorod structure on an acid-etched, microstructured titanium plate surface using hydrogen peroxide. We also evaluated biofunctionalization of the hybrid micro/nanorod topography on rat bone marrow mesenchymal stem cells. Scanning electron microscopy and x-ray diffraction were used to investigate the surface topography and phase composition of the modified titanium plate. Rat bone marrow mesenchymal stem cells were cultured and seeded on the plate. The adhesion ability of the cells was then assayed by cell counting at one, 4, and 24 hours after cell seeding, and expression of adhesion-related protein integrin β1 was detected by immunofluorescence. In addition, a polymerase chain reaction assay, alkaline phosphatase and Alizarin Red S staining assays, and osteopontin and osteocalcin immunofluorescence analyses were used to evaluate the osteogenic differentiation behavior of the cells. The hybrid micro/nanoscale texture formed on the titanium surface enhanced the initial adhesion activity of the rat bone marrow mesenchymal stem cells. Importantly, the hierarchical structure promoted osteogenic differentiation of these cells. This study suggests that a hybrid micro/nanorod topography on a titanium surface fabricated by treatment with hydrogen peroxide followed by acid etching might facilitate osseointegration of a titanium implant in vivo.

  20. Evaluation of structural and mechanical properties of electrospun nano-micro hybrid of poly hydroxybutyrate-chitosan/silk scaffold for cartilage tissue engineering.

    Science.gov (United States)

    Karbasi, Saeed; Fekrat, Farnoosh; Semnani, Daryoush; Razavi, Shahnaz; Zargar, Elham Naghash

    2016-01-01

    One of the new methods of scaffold fabrication is a nano-micro hybrid structure in which the properties of the scaffold are improved by introducing nanometer and micrometer structures. This method could be suitable for scaffold designing if some features improve. In this study, electrospun nanofibers of 9% weight solution of poly (3-hydroxybutyrate) (P3HB) and a 15% weight of chitosan by trifluoroacetic acid were coated on both the surface of a silk knitted substrate in the optimum condition to improve the mechanical properties of scaffolds for cartilage tissue engineering application. These hybrid nano-micro fibrous scaffolds were characterized by structural and mechanical evaluation methods. Scanning electron microscopy values and porosity analysis showed that average diameter of nanofibers was 584.94 nm in electrospinning part and general porosity was more than 80%. Fourier transform infrared spectroscopy results indicated the presence of all elements without pollution. The tensile test also stated that by electrospinning, as well as adding chitosan, both maximum strength and maximum elongation increased to 187 N and 10 mm. It means that the microfibrous part of scaffold could affect mechanical properties of nano part of the hybrid scaffold, significantly. It could be concluded that P3HB-chitosan/silk hybrid scaffolds can be a good candidate for cartilage tissue engineering.

  1. Transition towards DC micro grids: From an AC to a hybrid AC and DC energy infrastructure

    Directory of Open Access Journals (Sweden)

    Evi Ploumpidou

    2017-12-01

    Full Text Available Our electricity is predominantly powered by alternating current (AC, ever since the War of Currents ended in the favor of Nicola Tesla at the end of the 19th century. However, lots of the appliances we use, such as electronics and lights with light-emitting diode (LED technology, work internally on direct current (DC and it is projected that the number of these appliances will increase in the near future. Another contributor to the increase in DC consumption is the ongoing electrification of mobility (Electric Vehicles (EVs. At the same time, photovoltaics (PV generate DC voltages, while the most common storage technologies also use DC. In order to integrate all these appliances and technologies to the existing AC grid, there is a need for converters which introduce power losses. By distributing DC power to DC devices instead of converting it to AC first, it is possible to avoid substantial energy losses that occur every time electricity is converted. This situation initiated the concept for the implementation of the DC-Flexhouse project. A prototype DC installation will be developed and tested in one of the buildings of the developing living lab area called the District of Tomorrow (De Wijk van Morgen which is located in Heerlen, the Netherlands. A neighborhood cooperative (Vrieheide cooperatie is also part of the consortium in order to address the aspect of social acceptance. Although DC seems to be a promising solution for a more sustainable energy system, the business case is still debatable due to both technology- and market-related challenges. The current energy infrastructure is predominantly based on AC, manufacturers produce devices based on AC standards and people are using many AC products across a long life span. This Smart Energy Buildings & Cities (SEB&C PDEng project is a contribution to the DC-Flexhouse project. The aim is to analyze the challenges in the transition to DC micro grids, assess the market potential of DC

  2. Reliability of hybrid photovoltaic DC micro-grid systems for emergency shelters and other applications

    Science.gov (United States)

    Dhere, Neelkanth G.; Schleith, Susan

    2014-10-01

    Improvement of energy efficiency in the SunSmart Schools Emergency Shelters requires new methods for optimizing the energy consumption within the shelters. One major limitation in current systems is the requirement of converting direct current (DC) power generated from the PV array into alternating current (AC) power which is distributed throughout the shelters. Oftentimes, this AC power is then converted back to DC to run certain appliances throughout the shelters resulting in a significant waste of energy due to DC to AC and then again AC to DC conversion. This paper seeks to extract the maximum value out of PV systems by directly powering essential load components within the shelters that already run on DC power without the use of an inverter and above all to make the system reliable and durable. Furthermore, additional DC applications such as LED lighting, televisions, computers and fans operated with DC brushless motors will be installed as replacements to traditional devices in order to improve efficiency and reduce energy consumption. Cost of energy storage technologies continue to decline as new technologies scale up and new incentives are put in place. This will provide a cost effective way to stabilize the energy generation of a PV system as well as to provide continuous energy during night hours. It is planned to develop a pilot program of an integrated system that can provide uninterrupted DC power to essential base load appliances (heating, cooling, lighting, etc.) at the Florida Solar Energy Center (FSEC) command center for disaster management. PV arrays are proposed to be installed on energy efficient test houses at FSEC as well as at private homes having PV arrays where the owners volunteer to participate in the program. It is also planned to monitor the performance of the PV arrays and functioning of the appliances with the aim to improve their reliability and durability. After a successful demonstration of the hybrid DC microgrid based emergency

  3. Hybrid Energy Cell with Hierarchical Nano/Micro-Architectured Polymer Film to Harvest Mechanical, Solar, and Wind Energies Individually/Simultaneously.

    Science.gov (United States)

    Dudem, Bhaskar; Ko, Yeong Hwan; Leem, Jung Woo; Lim, Joo Ho; Yu, Jae Su

    2016-11-09

    We report the creation of hybrid energy cells based on hierarchical nano/micro-architectured polydimethylsiloxane (HNMA-PDMS) films with multifunctionality to simultaneously harvest mechanical, solar, and wind energies. These films consist of nano/micro dual-scale architectures (i.e., nanonipples on inverted micropyramidal arrays) on the PDMS surface. The HNMA-PDMS is replicable by facile and cost-effective soft imprint lithography using a nanoporous anodic alumina oxide film formed on the micropyramidal-structured silicon substrate. The HNMA-PDMS film plays multifunctional roles as a triboelectric layer in nanogenerators and an antireflection layer for dye-sensitized solar cells (DSSCs), as well as a self-cleaning surface. This film is employed in triboelectric nanogenerator (TENG) devices, fabricated by laminating it on indium-tin oxide-coated polyethylene terephthalate (ITO/PET) as a bottom electrode. The large effective contact area that emerged from the densely packed hierarchical nano/micro-architectures of the PDMS film leads to the enhancement of TENG device performance. Moreover, the HNMA-PDMS/ITO/PET, with a high transmittance of >90%, also results in highly transparent TENG devices. By placing the HNMA-PDMS/ITO/PET, where the ITO/PET is coated with zinc oxide nanowires, as the top glass substrate of DSSCs, the device is able to add the functionality of TENG devices, thus creating a hybrid energy cell. The hybrid energy cell can successfully convert mechanical, solar, and wind energies into electricity, simultaneously or independently. To specify the device performance, the effects of external pushing frequency and load resistance on the output of TENG devices are also analyzed, including the photovoltaic performance of the hybrid energy cells.

  4. Iron oxide functionalized graphene oxide as an efficient sorbent for dispersive micro-solid phase extraction of sulfadiazine followed by spectrophotometric and mode-mismatched thermal lens spectrometric determination.

    Science.gov (United States)

    Kazemi, Elahe; Dadfarnia, Shayessteh; Haji Shabani, Ali Mohammad; Abbasi, Amir; Rashidian Vaziri, Mohammad Reza; Behjat, Abbas

    2016-01-15

    A simple and rapid dispersive micro-solid phase extraction (DMSPE) combined with mode-mismatched thermal lens spectrometry as well as fiber optic linear array spectrophotometry was developed for the separation, extraction and determination of sulfadiazine. Graphene oxide was synthesized using the modified Hummers method and functionalized with iron oxide nanoparticles by means of a simple one step chemical coprecipitation method. The synthesized iron oxide functionalized graphene oxide was utilized as an efficient sorbent in DMSPE of sulfadiazine. The retained analyte was eluted by using 180µL of a 6:4 mixture of methanol/acetic acid solution and was spectrophotometrically determined based on the formation of an azo dye through coupling with thenoyltrifluoroacetone. Under the optimized conditions, with the application of spectrophotometry technique and with a sample volume of 100mL, the method exhibited a linear dynamic range of 3-80µg L(-1) with a detection limit of 0.82µg L(-1), an enrichment factor of 200 as well as the relative standard deviations of 2.6% and 4.3% (n=6) at 150µg L(-1) level of sulfadiazine for intra- and inter-day analyses, respectively. Whereas, through the application of the thermal lens spectrometry and a sample volume of 10mL, the method exhibited a linear dynamic range of 1-800µg L(-1) with a detection limit of 0.34µg L(-1) and the relative standard deviations of 3.1% and 5.4% (n=6) at 150µg L(-1) level of sulfadiazine for intra- and inter-day analyses, respectively. The method was successfully applied to the determination of sulfadiazine in milk, honey and water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Transient Oscillations Analysis and Modified Control Strategy for Seamless Mode Transfer in Micro-Grids: A Wind-PV-ES Hybrid System Case Study

    Directory of Open Access Journals (Sweden)

    Tengfei Zhang

    2015-12-01

    Full Text Available With the rapid development of the micro-grid associated with new and clean energies, the smooth switching between grid-connected and islanded operation modes of the micro-grid is a key issue that needs to be addressed urgently. In traditional solutions, V/f (Voltage/frequency control is adopted for the master micro sources when the micro-grid works in islanded mode, while PQ (real and reactive power control is adopted when in grid-connected mode. However, when the two controllers switch when mode transfer occurs, transient oscillations usually occur and thereafter the dynamic response will be degraded. This paper considers an archetypical micro-grid with Wind-PV-ES (Wind, Photovoltaic and Energy Storage hybrid system, which forms the basis of our case study. The underlying reason for such transient oscillation is analyzed in this paper. Thereafter a modified control strategy for seamless mode transfer is designed and implemented. An improved PQ control method is designed by which the output of the PQ controller always synchronously tracks the output of the V/f controller for micro-grid switches from islanded mode to grid-connected; furthermore, a dq rotating coordinate synchronization based V/f control method is proposed for transition from grid-connected mode to islanded mode. Finally, experiments and analysis are undertaken on some basic and important operating cases; the results in our case study indicate that the modified control strategy is effective in dominating the micro-grid during mode transfer and thus yielding significantly better performances.

  6. Thermal Analysis of Hybrid Thermal Control System and Experimental Investigation of Flow Boiling in Micro-channel Heat Exchangers

    Science.gov (United States)

    Lee, Seunghyun

    Future manned space endeavors will require a new class of vehicles, capable of conducting different types of missions and enduring varying gravitational and temperature environments. Thermal management will play a vital role in these new vehicles, and is complicated by the need to tackle both low and high heat sink temperatures. The present study assesses the feasibility of hybrid thermal control system by thermodynamic analysis and investigates the heat transfer mechanisms in two large micro-channel heat exchangers in vapor compression mode and two-phase mode. Unlike prior published two-phase micro-channel studies that concern mostly miniature heat sinks, this study addresses transport characteristics of a heat sink containing large length-to-diameter ratio, up to 609.6 to 1,micro-channels. In the thermodynamic analysis, four different operational modes are considered: single-phase, two-phase, basic heat pump and heat pump with liquid-side, suction-side heat exchanger. A thermodynamic trade study is conducted for six different working fluids to assess important performance parameters including mass flow rate of the working fluid, maximum pressure, radiator area, compressor/pump work, and coefficient of performance (COP). R134a is determined to be most suitable based on its ability to provide a balanced compromise between reducing flow rate and maintaining low system pressure, and a moderate coefficient of performance (COP); this fluid is also both nontoxic and nonflammable, and features zero ozone depletion potential (ODP) and low global warming potential (GWP). It is shown how specific mission stages dictate which mode of operation is most suitable, and this information is used to size the radiator for the H-TCS. The experimental flow boiling investigation consists of exploring the steady-state and the transient two-phase heat transfer characteristics of two large micro-channel heat exchangers that serve as evaporators in the vapor compression loop using R134a as

  7. Micro-hybrid electric vehicle application of valve-regulated lead-acid batteries in absorbent glass mat technology: Testing a partial-state-of-charge operation strategy

    Energy Technology Data Exchange (ETDEWEB)

    Schaeck, S.; Stoermer, A.O.; Hockgeiger, E. [BMW Group, Powertrain Development, Energy Storage, Hufelandstrasse 4, 80788 Muenchen (Germany)

    2009-05-01

    The BMW Group has launched two micro-hybrid functions in high volume models in order to contribute to reduction of fuel consumption in modern passenger cars. Both the brake energy regeneration (BER) and the auto-start-stop function (ASSF) are based on the conventional 14 V vehicle electrical system and current series components with only little modifications. An intelligent control algorithm of the alternator enables recuperative charging in braking and coasting phases, known as BER. By switching off the internal combustion engine at a vehicle standstill the idling fuel consumption is effectively reduced by ASSF. By reason of economy and package a lead-acid battery is used as electrochemical energy storage device. The BMW Group assembles valve-regulated lead-acid (VRLA) batteries in absorbent glass mat (AGM) technology in the micro-hybrid electrical power system since special challenges arise for the batteries. By field data analysis a lower average state-of-charge (SOC) due to partial state-of-charge (PSOC) operation and a higher cycling rate due to BER and ASSF are confirmed in this article. Similar to a design of experiment (DOE) like method we present a long-term lab investigation. Two types of 90 Ah VRLA AGM batteries are operated with a test bench profile that simulates the micro-hybrid vehicle electrical system under varying conditions. The main attention of this lab testing is focused on capacity loss and charge acceptance over cycle life. These effects are put into context with periodically refresh charging the batteries in order to prevent accelerated battery aging due to hard sulfation. We demonstrate the positive effect of refresh chargings concerning preservation of battery charge acceptance. Furthermore, we observe moderate capacity loss over 90 full cycles both at 25 C and at 3 C battery temperature. (author)

  8. Micro-hybrid electric vehicle application of valve-regulated lead-acid batteries in absorbent glass mat technology: Testing a partial-state-of-charge operation strategy

    Science.gov (United States)

    Schaeck, S.; Stoermer, A. O.; Hockgeiger, E.

    The BMW Group has launched two micro-hybrid functions in high volume models in order to contribute to reduction of fuel consumption in modern passenger cars. Both the brake energy regeneration (BER) and the auto-start-stop function (ASSF) are based on the conventional 14 V vehicle electrical system and current series components with only little modifications. An intelligent control algorithm of the alternator enables recuperative charging in braking and coasting phases, known as BER. By switching off the internal combustion engine at a vehicle standstill the idling fuel consumption is effectively reduced by ASSF. By reason of economy and package a lead-acid battery is used as electrochemical energy storage device. The BMW Group assembles valve-regulated lead-acid (VRLA) batteries in absorbent glass mat (AGM) technology in the micro-hybrid electrical power system since special challenges arise for the batteries. By field data analysis a lower average state-of-charge (SOC) due to partial state-of-charge (PSOC) operation and a higher cycling rate due to BER and ASSF are confirmed in this article. Similar to a design of experiment (DOE) like method we present a long-term lab investigation. Two types of 90 Ah VRLA AGM batteries are operated with a test bench profile that simulates the micro-hybrid vehicle electrical system under varying conditions. The main attention of this lab testing is focused on capacity loss and charge acceptance over cycle life. These effects are put into context with periodically refresh charging the batteries in order to prevent accelerated battery aging due to hard sulfation. We demonstrate the positive effect of refresh chargings concerning preservation of battery charge acceptance. Furthermore, we observe moderate capacity loss over 90 full cycles both at 25 °C and at 3 °C battery temperature.

  9. Recent advances with a hybrid micro-pattern gas detector operated in low pressure H2 and He, for AT-TPC applications

    Directory of Open Access Journals (Sweden)

    Cortesi Marco

    2018-01-01

    Full Text Available In view of a possible application as a charge-particle track readout for an Active-Target Time Projection Chamber (AT-TPC, the operational properties and performances of a hybrid Micro-Pattern Gaseous Detector (MPGD were investigated in pure low-pressure Hydrogen (H2 and Helium (He. The detector consists of a MICROMEsh GAseous Structure (MICROMEGAS coupled to a two-cascade THick Gaseous Electron Multiplier (THGEM as a pre-amplification stage. This study reports the effective gain dependence of the hybrid-MPGD at relevant pressure (in the range of 200-760 torr for different detector arrangements. The results of this work are relevant in the field of avalanche mechanism in low-pressure, low-mass noble gases, in particularly for applications of MPGD end-cap readout for active-target Time Projection Chambers (TPC in the field of nuclear physics and nuclear astrophysics.

  10. Design and application of a technologically explicit hybrid energy-economy policy model with micro and macro economic dynamics

    Science.gov (United States)

    Bataille, Christopher G. F.

    2005-11-01

    Are further energy efficiency gains, or more recently greenhouse gas reductions, expensive or cheap? Analysts provide conflicting advice to policy makers based on divergent modelling perspectives, a 'top-down/bottom-up debate' in which economists use equation based models that equilibrate markets by maximizing consumer welfare, and technologists use technology simulation models that minimize the financial cost of providing energy services. This thesis summarizes a long term research project to find a middle ground between these two positions that is more useful to policy makers. Starting with the individual components of a behaviourally realistic and technologically explicit simulation model (ISTUM---Inter Sectoral Technology Use Model), or "hybrid", the individual sectors of the economy are linked using a framework of micro and macro economic feedbacks. These feedbacks are taken from the economic theory that informs the computable general equilibrium (CGE) family of models. Speaking in the languages of both economists and engineers, the resulting "physical" equilibrium model of Canada (CIMS---Canadian Integrated Modeling System), equilibrates energy and end-product markets, including imports and exports, for seven regions and 15 economic sectors, including primary industry, manufacturing, transportation, commerce, residences, governmental infrastructure and the energy supply sectors. Several different policy experiments demonstrate the value-added of the model and how its results compare to top-down and bottom-up practice. In general, the results show that technical adjustments make up about half the response to simulated energy policy, and macroeconomic demand adjustments the other half. Induced technical adjustments predominate with minor policies, while the importance of macroeconomic demand adjustment increases with the strength of the policy. Results are also shown for an experiment to derive estimates of future elasticity of substitution (ESUB) and

  11. Converging or Diverging Lens?

    Science.gov (United States)

    Branca, Mario

    2013-01-01

    Why does a lens magnify? Why does it shrink objects? Why does this happen? The activities that we propose here are useful in helping us to understand how lenses work, and they show that the same lens can have different magnification capabilities. A converging lens can also act as a diverging lens. (Contains 4 figures.)

  12. Lente de contato de material híbrido em pacientes com ceratocone e astigmatismo miópico composto Hybrid material contact lens in keratoconus and myopic astigmatism patients

    Directory of Open Access Journals (Sweden)

    Fernando Leal

    2007-03-01

    óculos, exceto para a freqüência B (3 cpg, maior nos usuários de óculos. As aberrações de alta ordem analisadas apresentaram diminuição estatisticamente significante, quando comparados os pacientes sem e com uso de lentes de contato, com exceção da aberração esférica e do coma. CONCLUSÃO: A lente de contato de material híbrido, quando utilizada por portadores de ceratocone e astigmatismo miópico composto, propiciaram desempenho visual e conforto satisfatórios, em níveis que não diferiram, das lentes de contato rígidas-gás-permeáveis nos dois grupos de pacientes.PURPOSE: To evaluate comfort and visual performance in relation to two different used contact lens types: hybrid material (HM and rigid-gas-permeable (RGP, in patients with regular myopic astigmatism and with keratoconus. METHODS: A randomized, double masked, prospective study of 22 patients with the diagnosis of myopic astigmatism (8 with myopic astigmatism and 14 with keratoconus was conducted. Fifteen patients were female and 7 were male, and mean age was: 32.13 ± 8.12 years. In one of the eyes a rigid-gas-permeable contact lens was adapted (DK 30, and in the other a hybrid material contact lens was adapted (DK 23. All patients were submitted to the following tests: measurement of comfort level by means of the analogical visual scale, tear break-up time, best corrected visual acuity with the Bailey-Lovie scale adapted for 4 meters, functional acuity contrast test (FACT and wavefront analysis. RESULTS: In relation to comfort, there was no association with the evaluated contact lens type (p=0.350. There was a variation in comfort level during the first 7 days. The visual acuity increased between the 7th and the 15th day of adaptation. Visual acuity stabilized right after this period. The visual acuity did not show differences in relation to the studied lens type. It was verified that there was no difference in the tear break-up time (p=0.989 in relation to the studied lenses type and

  13. Identification of strain fields in pure Al and hybrid Ni/Al metal foams using X-ray micro-tomography under loading

    International Nuclear Information System (INIS)

    Fíla, T.; Jiroušek, O.; Jung, A.; Kumpová, I.

    2016-01-01

    Hybrid foams are materials formed by a core from a standard open cell metal foam that is during the process of electrodeposition coated by a thin layer of different nanocrystalline metals. The material properties of the base metal foam are in this way modified resulting in higher plateau stress and, more importantly, by introduction of strain-rate dependence to its deformation response. In this paper, we used time-lapse X-ray micro-tomography for the mechanical characterization of Ni/Al hybrid foams (aluminium open cell foams with nickel coating layer). To fully understand the effects of the coating layer on the material's effective properties, we compared the compressive response of the base uncoated foam to the response of the material with coating thickness of 50 and 75 μm. Digital volume correlation (DVC) was applied to obtain volumetric strain fields of the deforming micro-structure up to the densification region of the deforming cellular structure. The analysis was performed as a compressive mechanical test with simultaneous observation using X-ray radiography and tomography. A custom design experimental device was used for compression of the foam specimens in several deformation states directly in the X-ray setup. Planar X-ray images were taken during the loading phases and a X-ray tomography was performed at the end of each loading phase (up to engineering strain 22%). The samples were irradiated using micro-focus reflection type X-ray tube and images were taken using a large area flat panel detector. Tomography reconstructions were used for an identification of a strain distribution in the foam using digital volumetric correlation. A comparison of the deformation response of the coated and the uncoated foam in uniaxial quasi-static compression is summarized in the paper.

  14. 4E analysis and multi objective optimization of a micro gas turbine and solid oxide fuel cell hybrid combined heat and power system

    Science.gov (United States)

    Sanaye, Sepehr; Katebi, Arash

    2014-02-01

    Energy, exergy, economic and environmental (4E) analysis and optimization of a hybrid solid oxide fuel cell and micro gas turbine (SOFC-MGT) system for use as combined generation of heat and power (CHP) is investigated in this paper. The hybrid system is modeled and performance related results are validated using available data in literature. Then a multi-objective optimization approach based on genetic algorithm is incorporated. Eight system design parameters are selected for the optimization procedure. System exergy efficiency and total cost rate (including capital or investment cost, operational cost and penalty cost of environmental emissions) are the two objectives. The effects of fuel unit cost, capital investment and system power output on optimum design parameters are also investigated. It is observed that the most sensitive and important design parameter in the hybrid system is fuel cell current density which has a significant effect on the balance between system cost and efficiency. The selected design point from the Pareto distribution of optimization results indicates a total system exergy efficiency of 60.7%, with estimated electrical energy cost 0.057 kW-1 h-1, and payback period of about 6.3 years for the investment.

  15. Lens transmission measurement for an absolute radiation thermometer

    International Nuclear Information System (INIS)

    Hao, X.; Yuan, Z.; Lu, X.

    2013-01-01

    The lens transmission for the National Institute of Metrology of China absolute radiation thermometer is measured by a hybrid method. The results of the lens transmission measurements are 99.002% and 86.792% for filter radiometers with center wavelengths 633 nm and 900 nm, respectively. These results, after correcting for diffraction factors and the size-of-source effect when the lens is incorporated within the radiometer, can be used for measurement of thermodynamic temperature. The expanded uncertainty of the lens transmission measurement system has been evaluated. It is 1.3×10 −3 at 633 nm and 900 nm, respectively

  16. Fiscal 2000 report on the international joint verification of photovoltaic power generation system. Verification of hybrid system comprising photovoltaic power generation system and micro-hydroelectric power generation systems; 2000 nendo taiyoko hatsuden system kokusai kyodo jissho kaihatsu hokokusho. Taiyoko micro suiryoku hybrid system jissho kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-06-01

    Research was conducted in Vietnam for the development of a hybrid system comprising a photovoltaic power generation system and a micro-hydroelectric power generation system. In verification test operation, data measurement had been under way for approximately 18 months since it was started in September 1999. The rate of days on which effective data were obtained throughout this period was 93.4%. Power generated by the micro-hydroelectric power generation system was 19.4kWh/d with so small a capacity factor of 3.2%. The capacity factor of the photovoltaic power generation system was again very small at 4.5% since the amount consumed by the load was as small as 131.0kWh/d. Weather data of solar radiation and precipitation were being collected smoothly. In the study of hybrid system optimization, the effect of inductor generator activation upon the inverter was taken up. In the study of capacity balance optimization between the constituent elements of the hybrid system, methodology was established and verified, and calculations were carried out. (NEDO)

  17. Single lens to lens duplication: The missing link

    OpenAIRE

    Bhatt, Rupal; Jethani, Jitendra; Saluja, Praveen; Bharti, Vinay

    2008-01-01

    Congenital anomalies of the lens include a wide range from lens coloboma to primary aphakia and doubling of lens. There have been few case reports of double lens; the etiology suggested is metaplastic changes in the surface ectoderm that leads to formation of two lens vesicles and hence resulting in double lens. We report a case with bilobed lens, which raises the possibility of explaining the etiology of double lens.

  18. Contact Lens Care

    Science.gov (United States)

    ... Consumers Consumer Information by Audience For Women Contact Lens Care Share Tweet Linkedin Pin it More sharing ... www.fda.gov/medwatch Learn More about Contact Lens Care Other Tips on Contact Lenses Decorative Contact ...

  19. Exergy analysis and optimization of a biomass gasification, solid oxide fuel cell and micro gas turbine hybrid system

    DEFF Research Database (Denmark)

    Bang-Møller, Christian; Rokni, Masoud; Elmegaard, Brian

    2011-01-01

    and exergy analyses were applied. Focus in this optimization study was heat management, and the optimization efforts resulted in a substantial gain of approximately 6% in the electrical efficiency of the plant. The optimized hybrid plant produced approximately 290 kWe at an electrical efficiency of 58...

  20. Full and part load exergetic analysis of a hybrid micro gas turbine fuel cell system based on existing components

    International Nuclear Information System (INIS)

    Bakalis, Diamantis P.; Stamatis, Anastassios G.

    2012-01-01

    Highlights: ► Hybrid SOFC/GT system based on existing components. ► Exergy analysis using AspenPlus™ software. ► Greenhouse gases emission is significantly affected by SOFC stack temperature. ► Comparison with a conventional GT of similar power. ► SOFC/GT is almost twice efficient in terms of second low efficiency and CO 2 emission. - Abstract: The paper deals with the examination of a hybrid system consisting of a pre-commercially available high temperature solid oxide fuel cell and an existing recuperated microturbine. The irreversibilities and thermodynamic inefficiencies of the system are evaluated after examining the full and partial load exergetic performance and estimating the amount of exergy destruction and the efficiency of each hybrid system component. At full load operation the system achieves an exergetic efficiency of 59.8%, which increases during the partial load operation, as a variable speed control method is utilized. Furthermore, the effects of the various performance parameters such as fuel cell stack temperature and fuel utilization factor are assessed. The results showed that the components in which chemical reactions occur have the higher exergy destruction rates. The exergetic performance of the system is affected significantly by the stack temperature. Based on the exergetic analysis, suggestions are given for reducing the overall system irreversibility. Finally, the environmental impact of the operation of the hybrid system is evaluated and compared with a similarly rated conventional gas turbine plant. From the comparison it is apparent that the hybrid system obtains nearly double exergetic efficiency and about half the amount of greenhouse gas emissions compared with the conventional plant.

  1. Aberration design of zoom lens systems using thick lens modules.

    Science.gov (United States)

    Zhang, Jinkai; Chen, Xiaobo; Xi, Juntong; Wu, Zhuoqi

    2014-12-20

    A systematic approach for the aberration design of a zoom lens system using a thick lens module is presented. Each component is treated as a thick lens module at the beginning of the design. A thick lens module refers to a thick lens component with a real lens structure, like lens materials, lens curvatures, lens thicknesses, and lens interval distances. All nine third-order aberrations of a thick lens component are considered during the design. The relationship of component aberrations in different zoom positions can be approximated from the aberration shift. After minimizing the aberrations of the zoom lens system, the nine third-order aberrations of every lens component can be determined. Then the thick lens structure of every lens component can be determined after optimization according to their first-order properties and third-order aberration targets. After a third optimization for minimum practical third-order aberrations of a zoom lens system, the aberration design using the thick lens module is complete, which provides a practical zoom lens system with thick lens structures. A double-sided telecentric zoom lens system is designed using the thick lens module in this paper, which shows that this method is practical for zoom lens design.

  2. P.I.X.S.C.A.N.: a micro-CT scanner for small animal based on hybrid pixel detectors

    International Nuclear Information System (INIS)

    Khoury, R.

    2008-03-01

    Since more than a dozen years, efforts were led in the field of X-ray tomography for small animals, principally for the improvement of spatial resolution and the diminution of the absorbed dose. The C.P.P.M. developed the micro-CT P.I.X.S.C.A.N. based on the hybrid pixel detector X.P.A.D.2. In this context, my thesis work consists in studying the demonstrator P.I.X.S.C.A.N./X.P.A.D.2 and the contribution of the hybrid pixels in the imaging of small animals. A fast analytical simulation, FastSimu, was developed. An extrapolation of the performance of the demonstrator P.I.X.S.C.A.N, as well as the validation of the results obtained with the measured data, were led by means of the analytical simulator FastSimu. The demonstrator P.I.X.S.C.A.N./X.P.A.D.2 allowed to obtain reconstructed images with a rather good quality for a relatively weak absorbed dose. Its spatial resolution is degraded by the high number of defective pixels of the detector X.P.A.D.2. Beyond this study, a new version of the demonstrator P.I.X.S.C.A.N./X.P.A.D.2 is under construction. This latter, characterized by two and a half times smaller pixels and about no defective pixels will bring a considerable improvement on spatial resolution. (author)

  3. Effect of micro-nano-hybrid structured hydroxyapatite bioceramics on osteogenic and cementogenic differentiation of human periodontal ligament stem cell via Wnt signaling pathway

    Science.gov (United States)

    Mao, Lixia; Liu, Jiaqiang; Zhao, Jinglei; Chang, Jiang; Xia, Lunguo; Jiang, Lingyong; Wang, Xiuhui; Lin, Kaili; Fang, Bing

    2015-01-01

    The surface structure of bioceramic scaffolds is crucial for its bioactivity and osteoinductive ability, and in recent years, human periodontal ligament stem cells have been certified to possess high osteogenic and cementogenic differential ability. In the present study, hydroxyapatite (HA) bioceramics with micro-nano-hybrid surface (mnHA [the hybrid of nanorods and microrods]) were fabricated via hydrothermal reaction of the α-tricalcium phosphate granules as precursors in aqueous solution, and the effects of mnHA on the attachment, proliferation, osteogenic and cementogenic differentiations of human periodontal ligament stem cells as well as the related mechanisms were systematically investigated. The results showed that mnHA bioceramics could promote cell adhesion, proliferation, alkaline phosphatase (ALP) activity, and expression of osteogenic/cementogenic-related markers including runt-related transcription factor 2 (Runx2), ALP, osteocalcin (OCN), cementum attachment protein (CAP), and cementum protein (CEMP) as compared to the HA bioceramics with flat and dense surface. Moreover, mnHA bioceramics stimulated gene expression of low-density lipoprotein receptor-related protein 5 (LRP5) and β-catenin, which are the key genes of canonical Wnt signaling. Moreover, the stimulatory effect on ALP activity and osteogenic and cementogenic gene expression, including that of ALP, OCN, CAP, CEMP, and Runx2 of mnHA bioceramics could be repressed by canonical Wnt signaling inhibitor dickkopf1 (Dkk1). The results suggested that the HA bioceramics with mnHA could act as promising grafts for periodontal tissue regeneration. PMID:26648716

  4. High performance preconcentration of inorganic Se species by dispersive micro-solid phase extraction with a nanosilica-ionic liquid hybrid material

    Science.gov (United States)

    Llaver, Mauricio; Coronado, Eduardo A.; Wuilloud, Rodolfo G.

    2017-12-01

    A highly sensitive and efficient dispersive micro-solid phase extraction (D-μ-SPE) method was developed for inorganic Se speciation analysis. A novel ionic liquid (IL)-nanomaterial hybrid consisting of 1-dodecyl-3-methylimidazolium bromide-functionalized nanosilica was used for the efficient retention of Se(IV) complexed with ammonium pyrrolidine dithiocarbamate, followed by elution with an ethyl acetate/Triton X-114 mixture and determination by electrothermal atomic absorption spectroscopy. The Se(VI) species was selectively determined by difference between total inorganic Se and Se(IV) after pre-reduction. The IL-nanomaterial hybrid was characterized by Fourier transform infrared spectroscopy and transmission electronic microscopy. Likewise, Se(IV) sorption capacity of the retention material and maximum amount of IL loaded on its surface were determined. Several factors concerning the functionalization, extraction and elution steps were optimized, yielding a 100% extraction efficiency for Se(IV) under optimal conditions. A limit of detection of 1.1 ng L- 1, a relative standard deviation of 5.7% and a 110-fold enhancement factor were obtained. The D-μ-SPE method was successfully applied to several water samples from different origins and compositions, including rain, tap, underground, river and sea.

  5. Ultrasensitive electrochemical detection of microRNA-21 combining layered nanostructure of oxidized single-walled carbon nanotubes and nanodiamonds by hybridization chain reaction.

    Science.gov (United States)

    Liu, Lingzhi; Song, Chao; Zhang, Zhang; Yang, Juan; Zhou, Lili; Zhang, Xing; Xie, Guoming

    2015-08-15

    Measurement of microRNA (miRNA) levels in body fluids is a crucial tool for the early diagnosis and prognosis of cancers. In this study, we developed an electrochemical assay to detect miRNA-21 by fabricating the electrode with layer-by-layer assembly of oxidized single-walled carbon nanotubes and nanodiamonds. Tetrahedron-structured probes with free-standing probe on the top served as receptors to hybridize with target miRNA directly. The probes were immobilized on the deposited gold nanoparticles through a well-established strong Au-S bond. The electrochemical signal was mainly derived from an ultrasensitive pattern by combining hybridization chain reaction with DNA-functionalized AuNPs, which provided DNAzyme to catalyze H2O2 reduction. Differential pulse voltammetry was applied to record the electrochemical signals, which was increased linearly with the target miRNA-21, and the linear detection range was 10 fM to 1.0 nM. The limit of detection reached 1.95 fM (S/N=3), and the proposed biosensor exhibited good reproducibility and stability, as well as high sensitivity. Hence, this biosensor has a promising potential in clinical application. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Engineering a self-driven PVDF/PDA hybrid membranes based on membrane micro-reactor effect to achieve super-hydrophilicity, excellent antifouling properties and hemocompatibility

    Science.gov (United States)

    Li, Jian-Hua; Ni, Xing-Xing; Zhang, De-Bin; Zheng, Hui; Wang, Jia-Bin; Zhang, Qi-Qing

    2018-06-01

    A facile and versatile approach for the preparation of super-hydrophilic, excellent antifouling and hemocompatibility membranes had been developed through the generation in situ of bio-inspired polydopamine (PDA) microspheres on PVDF membranes. SEM images showed that the PDA microspheres were uniformly dispersed on the upper surface and the lower surface of the modified membranes. And there were a great number of PDA microspheres immobilized on the cross-section, but the interconnected pores structure was not destroyed. These facts indicated the existence of membrane micro-reactor effect for the whole membrane structure. Considering the remarkable improvement of hydrophilicity, antifouling properties, and permeation fluxes, we also proposed the cluster phenolic hydroxyl effect for the PVDF/PDA hybrid membranes. And the cluster phenolic hydroxyl effect can be ascribed to the all directions distributed phenolic hydroxyl groups on the whole membrane structure. Besides, the self-driven filtration experiments showed the great wetting ability and permeability of the PVDF/PDA hybrid membranes in filtration process without any external pressure. This implied the existence of accelerating self-driven force after the water flow flowed into the internal of membranes, which contributed to the increase of water flow velocity. All the three aspects were in favor of the enhancement of hydrophilicity, antifouling properties and permeability of the modified membranes. Moreover, the conventional filtration tests, oil/water emulsion filtration tests and protein adsorption tests were also carried out to discuss the practical applications of PVDF/PDA hybrid membranes. And the hemocompatibility of the modified membranes was also proved to enhance greatly through the hemolysis tests and platelet adhesion tests, indicating that the membranes were greatly promising in biomedical applications. The strategy of material modification reported here is substrate-independent and can be extended

  7. Freeform micromachining of an infrared Alvarez lens

    Science.gov (United States)

    Smilie, Paul J.; Dutterer, Brian S.; Lineberger, Jennifer L.; Davies, Matthew A.; Suleski, Thomas J.

    2011-02-01

    In 1967, Luis Alvarez introduced a novel concept for a focusing lens whereby two transmitting elements with cubic polynomial surfaces yield a composite lens of variable focal length with small lateral shifts. Computer simulations have demonstrated the behavior of these devices, but fabricating the refractive cubic surfaces of the types needed with adequate precision and depth modulation has proven to be challenging using standard methods, and, to the authors' knowledge, Alvarez lens elements have not been previously machined in infrared materials. Recent developments in freeform diamond machining capability have enabled the fabrication of such devices. In this paper, we discuss the fabrication of freeform refractive Alvarez elements in germanium using diamond micro-milling on a five-axis Moore Nanotech® 350FG Freeform Generator. Machining approaches are discussed, and measurements of surface figure and finish are presented. Initial experimental tests of optical performance are also discussed.

  8. Fuzzy Expert System based on a Novel Hybrid Stem Cell (HSC) Algorithm for Classification of Micro Array Data.

    Science.gov (United States)

    Vijay, S Arul Antran; GaneshKumar, P

    2018-02-21

    In the growing scenario, microarray data is extensively used since it provides a more comprehensive understanding of genetic variants among diseases. As the gene expression samples have high dimensionality it becomes tedious to analyze the samples manually. Hence an automated system is needed to analyze these samples. The fuzzy expert system offers a clear classification when compared to the machine learning and statistical methodologies. In fuzzy classification, knowledge acquisition would be a major concern. Despite several existing approaches for knowledge acquisition much effort is necessary to enhance the learning process. This paper proposes an innovative Hybrid Stem Cell (HSC) algorithm that utilizes Ant Colony optimization and Stem Cell algorithm for designing fuzzy classification system to extract the informative rules to form the membership functions from the microarray dataset. The HSC algorithm uses a novel Adaptive Stem Cell Optimization (ASCO) to improve the points of membership function and Ant Colony Optimization to produce the near optimum rule set. In order to extract the most informative genes from the large microarray dataset a method called Mutual Information is used. The performance results of the proposed technique evaluated using the five microarray datasets are simulated. These results prove that the proposed Hybrid Stem Cell (HSC) algorithm produces a precise fuzzy system than the existing methodologies.

  9. Characterization of continuous and pulsed emission modes of a hybrid micro focus x-ray source for medical imaging applications

    Energy Technology Data Exchange (ETDEWEB)

    Ghani, Muhammad U.; Wong, Molly D.; Ren, Liqiang; Wu, Di; Zheng, Bin [Center for Biomedical Engineering and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK 73019 (United States); Rong, John X. [Department of Imaging Physics, University of Texas MD Anderson Cancer Center, Houston, TX 77030 (United States); Wu, Xizeng [Department of Radiology, University of Alabama at Birmingham, Birmingham, AL 35249 (United States); Liu, Hong, E-mail: liu@ou.edu [Center for Biomedical Engineering and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK 73019 (United States)

    2017-05-01

    The aim of this study was to quantitatively characterize a micro focus x-ray tube that can operate in both continuous and pulsed emission modes. The micro focus x-ray source (Model L9181-06, Hamamatsu Photonics, Japan) has a varying focal spot size ranging from 16 µm to 50 µm as the source output power changes from 10 to 39 W. We measured the source output, beam quality, focal spot sizes, kV accuracy, spectra shapes and spatial resolution. Source output was measured using an ionization chamber for various tube voltages (kVs) with varying current (µA) and distances. The beam quality was measured in terms of half value layer (HVL), kV accuracy was measured with a non-invasive kV meter, and the spectra was measured using a compact integrated spectrometer system. The focal spot sizes were measured using a slit method with a CCD detector with a pixel pitch of 22 µm. The spatial resolution was quantitatively measured using the slit method with a CMOS flat panel detector with a 50 µm pixel pitch, and compared to the qualitative results obtained by imaging a contrast bar pattern. The focal spot sizes in the vertical direction were smaller than that of the horizontal direction, the impact of which was visible when comparing the spatial resolution values. Our analyses revealed that both emission modes yield comparable imaging performances in terms of beam quality, spectra shape and spatial resolution effects. There were no significantly large differences, thus providing the motivation for future studies to design and develop stable and robust cone beam imaging systems for various diagnostic applications. - Highlights: • A micro focus x-ray source that operates in both continuous and pulse emission modes was quantitatively characterized. • The source output, beam quality, focal spot measurements, kV accuracy, spectra analyses and spatial resolution were measured. • Our analyses revealed that both emission modes yield comparable imaging performances in terms of beam

  10. Characterization of continuous and pulsed emission modes of a hybrid micro focus x-ray source for medical imaging applications

    International Nuclear Information System (INIS)

    Ghani, Muhammad U.; Wong, Molly D.; Ren, Liqiang; Wu, Di; Zheng, Bin; Rong, John X.; Wu, Xizeng; Liu, Hong

    2017-01-01

    The aim of this study was to quantitatively characterize a micro focus x-ray tube that can operate in both continuous and pulsed emission modes. The micro focus x-ray source (Model L9181-06, Hamamatsu Photonics, Japan) has a varying focal spot size ranging from 16 µm to 50 µm as the source output power changes from 10 to 39 W. We measured the source output, beam quality, focal spot sizes, kV accuracy, spectra shapes and spatial resolution. Source output was measured using an ionization chamber for various tube voltages (kVs) with varying current (µA) and distances. The beam quality was measured in terms of half value layer (HVL), kV accuracy was measured with a non-invasive kV meter, and the spectra was measured using a compact integrated spectrometer system. The focal spot sizes were measured using a slit method with a CCD detector with a pixel pitch of 22 µm. The spatial resolution was quantitatively measured using the slit method with a CMOS flat panel detector with a 50 µm pixel pitch, and compared to the qualitative results obtained by imaging a contrast bar pattern. The focal spot sizes in the vertical direction were smaller than that of the horizontal direction, the impact of which was visible when comparing the spatial resolution values. Our analyses revealed that both emission modes yield comparable imaging performances in terms of beam quality, spectra shape and spatial resolution effects. There were no significantly large differences, thus providing the motivation for future studies to design and develop stable and robust cone beam imaging systems for various diagnostic applications. - Highlights: • A micro focus x-ray source that operates in both continuous and pulse emission modes was quantitatively characterized. • The source output, beam quality, focal spot measurements, kV accuracy, spectra analyses and spatial resolution were measured. • Our analyses revealed that both emission modes yield comparable imaging performances in terms of beam

  11. A dynamic model of a 100 kW micro gas turbine fuelled with natural gas and hydrogen blends and its application in a hybrid energy grid

    International Nuclear Information System (INIS)

    Di Gaeta, Alessandro; Reale, Fabrizio; Chiariello, Fabio; Massoli, Patrizio

    2017-01-01

    The paper deals with the development of a dynamic model of a commercial 100 kW Micro Gas Turbine (MGT) fuelled with mixtures of standard (i.e. natural gas or methane) and alternative fuels (i.e. hydrogen). The model consists of a first-order differential equation (ODE) describing the dominant dynamics of the MGT imposed by its own control system during production electrical power. The differential equation is coupled to a set of nonlinear maps derived numerically from a detailed 0D thermodynamic matching model of the MGT evaluated over a wide range of operating conditions (i.e. mechanical power, fraction of hydrogen and ambient temperature). The efficiency of the electrical machine with power inverter and power absorbed by auxiliary devices is also taken into account. The resulting model is experimentally validated for a sequence of power step responses of the MGT at different ambient conditions and with different fuel mixtures. The model is suited for simulation and control of hybrid energy grids (HEGs) which rely on advanced use of MGT and hydrogen as energy carrier. In this regard, the MGT model is used in the simulation of an HEG based on an appropriate mix of renewable (non-programmable) and non-renewable (programmable) energy sources with hydrogen storage and its reuse in the MGT. Here, the MGT is used as a programmable energy vector for compensating the deficits of renewable energies (such as solar and wind) with respect to user demand, while excess renewable energy is used to produce hydrogen via electrolysis of water. The simulated HEG comprises a solar PhotoVoltaic (PV) plant (300 kW), an MGT (100 kW) fuelled with natural gas and hydrogen blends, a water electrolyzer (WE) system (8 bar, 56 Nm 3 /h), a hydrogen tank (54 m 3 ), and an Energy Management Control System (EMCS). - Highlights: • A dynamic model of a commercial 100 kW MGT fuelled with natural gas and hydrogen blends is developed. • The model reproduces the electrical power generated by

  12. Dual-energy X-ray micro-CT imaging of hybrid Ni/Al open-cell foam

    International Nuclear Information System (INIS)

    Fíla, T.; Koudelka, P.; Zlámal, P.; Jiroušek, O.; Kumpová, I.; Vavřík, D.; Jung, A.

    2016-01-01

    In this paper, we employ dual-energy X-ray microfocus tomography (DECT) measurement to develop high-resolution finite element (FE) models that can be used for the numerical assessment of the deformation behaviour of hybrid Ni/Al foam subjected to both quasi-static and dynamic compressive loading. Cubic samples of hybrid Ni/Al open-cell foam with an edge length of [15]mm were investigated by the DECT measurement. The material was prepared using AlSi 7 Mg 0.3 aluminium foam with a mean pore size of [0.85]mm, coated with nanocrystalline nickel (crystallite size of approx. [50]nm) to form a surface layer with a theoretical thickness of [0.075]mm. CT imaging was carried out using state-of-the-art DSCT/DECT X-ray scanner developed at Centre of Excellence Telč. The device consists of a modular orthogonal assembly of two tube-detector imaging pairs, with an independent geometry setting and shared rotational stage mounted on a complex 16-axis CNC positioning system to enable unprecedented measurement variability for highly-detailed tomographical measurements. A sample of the metal foam was simultaneously irradiated using an XWT-240-SE reflection type X-ray tube and an XWT-160-TCHR transmission type X-ray tube. An enhanced dual-source sampling strategy was used for data acquisition. X-ray images were taken using XRD1622 large area GOS scintillator flat panel detectors with an active area of [410 × 410]mm and resolution [2048 × 2048]pixels. Tomographic scanning was performed in 1,200 projections with a 0.3 degree angular step to improve the accuracy of the generated models due to the very complex microstructure and high attenuation of the investigated material. Reconstructed data was processed using a dual-energy algorithm, and was used for the development of a 3D model and voxel model of the foam. The selected parameters of the models were compared with nominal parameters of the actual foam and showed good correlation

  13. Multiplexing schemes for an achromatic programmable diffractive lens

    Energy Technology Data Exchange (ETDEWEB)

    Millan, M S; Perez-Cabre, E; Oton, J [Technical University of Catalonia, Dep. Optics and Optometry, Terrassa-Barcelona, 08222 (Spain)], E-mail: millan@oo.upc.edu

    2008-11-01

    A multiplexed programmable diffractive lens, displayed on a pixelated liquid crystal device under broadband illumination, is proposed to compensate for the severe chromatic aberration that affects diffractive elements. The proposed lens is based on multiplexing a set of sublenses with a common focal length for different wavelengths. We consider different types of integration of the optical information (spatial only, temporal only and hybrid spatial-temporal) combined with a proper selection of the spectral bandwidth. The properties and limits of the achromatic programmable multiplexed lens are described. Experimental results are presented and discussed.

  14. Multiplexing schemes for an achromatic programmable diffractive lens

    International Nuclear Information System (INIS)

    Millan, M S; Perez-Cabre, E; Oton, J

    2008-01-01

    A multiplexed programmable diffractive lens, displayed on a pixelated liquid crystal device under broadband illumination, is proposed to compensate for the severe chromatic aberration that affects diffractive elements. The proposed lens is based on multiplexing a set of sublenses with a common focal length for different wavelengths. We consider different types of integration of the optical information (spatial only, temporal only and hybrid spatial-temporal) combined with a proper selection of the spectral bandwidth. The properties and limits of the achromatic programmable multiplexed lens are described. Experimental results are presented and discussed.

  15. Segmentation of 3D microPET images of the rat brain via the hybrid gaussian mixture method with kernel density estimation.

    Science.gov (United States)

    Chen, Tai-Been; Chen, Jyh-Cheng; Lu, Henry Horng-Shing

    2012-01-01

    Segmentation of positron emission tomography (PET) is typically achieved using the K-Means method or other approaches. In preclinical and clinical applications, the K-Means method needs a prior estimation of parameters such as the number of clusters and appropriate initialized values. This work segments microPET images using a hybrid method combining the Gaussian mixture model (GMM) with kernel density estimation. Segmentation is crucial to registration of disordered 2-deoxy-2-fluoro-D-glucose (FDG) accumulation locations with functional diagnosis and to estimate standardized uptake values (SUVs) of region of interests (ROIs) in PET images. Therefore, simulation studies are conducted to apply spherical targets to evaluate segmentation accuracy based on Tanimoto's definition of similarity. The proposed method generates a higher degree of similarity than the K-Means method. The PET images of a rat brain are used to compare the segmented shape and area of the cerebral cortex by the K-Means method and the proposed method by volume rendering. The proposed method provides clearer and more detailed activity structures of an FDG accumulation location in the cerebral cortex than those by the K-Means method.

  16. Live-Cell MicroRNA Imaging through MnO2 Nanosheet-Mediated DD-A Hybridization Chain Reaction.

    Science.gov (United States)

    Ou, Min; Huang, Jin; Yang, Xiaohai; He, Xiaoxiao; Quan, Ke; Yang, Yanjing; Xie, Nuli; Li, Jing; Wang, Kemin

    2018-01-18

    Innovative techniques to visualize native microRNAs (miRNAs) in live cells can dramatically impact current research on the roles of miRNA in biology and medicine. Here, we report a novel approach for live-cell miRNA imaging using a biodegradable MnO 2 nanosheet-mediated DD-A FRET hybridization chain reaction (HCR). The MnO 2 nanosheets can adsorb DNA hairpin probes and deliver them into live cells. After entering cells, the MnO 2 nanosheets are degraded by cellular GSH. Then, the target miR-21 triggers cascaded assembly of the liberated hairpin probes into long dsDNA polymers, which brings each two FAMs (donor) and one TAMRA (acceptor) into close proximity to generate significantly enhanced DD-A FRET signals, which was discovered and proven by our previous report. We think the developed approach can serve as an excellent intracellular miRNAs detection tool, which promises the potential for biological and disease studies. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Novel three-dimensional tin/carbon hybrid core/shell architecture with large amount of solid cross-linked micro/nanochannels for lithium ion battery application

    International Nuclear Information System (INIS)

    Yang, Zunxian; Meng, Qing; Yan, Wenhuan; Lv, Jun; Guo, Zaiping; Yu, Xuebin; Chen, Zhixin; Guo, Tailiang; Zeng, Rong

    2015-01-01

    Uniform Sn/C hybrid core/shell nanocomposites were synthesized by a combination of electrospinning and subsequent thermal treatment in a reducing atmosphere. The particular three-dimensional architecture, consisting of a Sn@C nanoparticle core and porous hollow carbon nanofiber shell, is characterized by many micro/nanochannels, enhanced mechanical support from the three-dimensional hollow carbon shell, and the abundant porous carbon matrix. The as-prepared Sn/C core/shell nanomaterials exhibit excellent electrochemical performance. They display a reversible capacity of 546.7 mAhg −1 up to 100 cycles at the current density of 40 mAg −1 and good rate capability of 181.8 mAhg −1 at 4000 mAg −1 . These results indicate that the composite could be a promising anode candidate for lithium ion batteries. - Highlights: • Sn/C core/shell composites were synthesized by an electrospinning, a hydrothermal process, and further thermal treatment. • The best-performing 3D composite consists of a Sn@C nanoparticle core and porous hollow carbon nanofiber shell. • The Sn/C composite electrode exhibit excellent Li ion storage capacity and cycling stability

  18. The comparison of the effects of different whitening toothpastes on the micro hardness of a nano hybrid composite resin.

    Science.gov (United States)

    Nainan, Mohan Thomas; Balan, Ashok Kalappurakkal; Sharma, Roshni; Thomas, Sabeena Susan; Deveerappa, Santhosh B

    2014-11-01

    The aim of this study was to compare the micro hardness of a nanohybrid composite resin after brushing with two herbal and one non-herbal whitening toothpastes. We divided Eighty disk-shaped specimens of a nanohybrid composite (Tetric N Ceram, Ivoclar Vivadent, Asia) into 4 groups of 20 specimens each: Groups A, B, C, and D. Group A was control, Group B was brushed with Colgate total advanced whitening (Colgate-Palmolive (India) Limited), Group C with Salt and Lemon, Dabur (Dabur International Limited, Dubai, UAE), and Group D with HiOra Shine, Himalaya (The Himalaya Drug Company, India). The specimens were polished using medium, fine, and superfine discs (Sof-lex, 3M, ESPE, USA) and subsequently placed at 37°C in distilled water. They were brushed for 2 minutes twice daily with a soft motorized toothbrush (Colgate 360 sonic power battery-operated tooth brush, Colgate Palmolive, India) for 30 days. The samples were rinsed under running water to remove the toothpaste and stored in distilled water at 37°C until the readout was taken on the Vickers's hardness tester for microhardness. The results revealed that the difference among the groups was statistically significant (P < 0.001). Tukey's test showed that reduction in microhardness for Group B was significantly higher than that for Group C and Group D (P < 0.001). Within the limitations of this study, non-herbal whitening toothpaste had a greater impact on the microhardness of nanohybrid resin composite than herbal whitening toothpastes.

  19. Capsular 'pits' in the human lens.

    OpenAIRE

    Harris, M. L.; Brown, N. A.; Shun-Shin, G. A.; Smith, G. T.

    1992-01-01

    The lens capsule is an atypical basement membrane surrounding the lens epithelial cells and lens fibres which make up the remainder of the human lens. A seemingly unreported morphological change visible in the lens capsule with the biomicroscope is described.

  20. Development of a novel mixed hemimicelles dispersive micro solid phase extraction using 1-hexadecyl-3-methylimidazolium bromide coated magnetic graphene for the separation and preconcentration of fluoxetine in different matrices before its determination by fiber optic linear array spectrophotometry and mode-mismatched thermal lens spectroscopy

    International Nuclear Information System (INIS)

    Kazemi, Elahe; Haji Shabani, Ali Mohammad; Dadfarnia, Shayessteh; Abbasi, Amir; Rashidian Vaziri, Mohammad Reza; Behjat, Abbas

    2016-01-01

    This study aims at developing a novel, sensitive, fast, simple and convenient method for separation and preconcentration of trace amounts of fluoxetine before its spectrophotometric determination. The method is based on combination of magnetic mixed hemimicelles solid phase extraction and dispersive micro solid phase extraction using 1-hexadecyl-3-methylimidazolium bromide coated magnetic graphene as a sorbent. The magnetic graphene was synthesized by a simple coprecipitation method and characterized by X-ray diffraction (XRD), Fourier transform infrared (FT-IR) spectroscopy and scanning electron microscopy (SEM). The retained analyte was eluted using a 100 μL mixture of methanol/acetic acid (9:1) and converted into fluoxetine-β-cyclodextrin inclusion complex. The analyte was then quantified by fiber optic linear array spectrophotometry as well as mode-mismatched thermal lens spectroscopy (TLS). The factors affecting the separation, preconcentration and determination of fluoxetine were investigated and optimized. With a 50 mL sample and under optimized conditions using the spectrophotometry technique, the method exhibited a linear dynamic range of 0.4–60.0 μg L"−"1, a detection limit of 0.21 μg L"−"1, an enrichment factor of 167, and a relative standard deviation of 2.1% and 3.8% (n = 6) at 60 μg L"−"1 level of fluoxetine for intra- and inter-day analyses, respectively. However, with thermal lens spectrometry and a sample volume of 10 mL, the method exhibited a linear dynamic range of 0.05–300 μg L"−"1, a detection limit of 0.016 μg L"−"1 and a relative standard deviation of 3.8% and 5.6% (n = 6) at 60 μg L"−"1 level of fluoxetine for intra- and inter-day analyses, respectively. The method was successfully applied to determine fluoxetine in pharmaceutical formulation, human urine and environmental water samples. - Graphical abstract: A novel, sensitive, fast, simple and convenient mixed hemimicelles dispersive micro solid

  1. Development of a novel mixed hemimicelles dispersive micro solid phase extraction using 1-hexadecyl-3-methylimidazolium bromide coated magnetic graphene for the separation and preconcentration of fluoxetine in different matrices before its determination by fiber optic linear array spectrophotometry and mode-mismatched thermal lens spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kazemi, Elahe; Haji Shabani, Ali Mohammad [Department of Chemistry, Yazd University, Safaieh, 89195-741, Yazd (Iran, Islamic Republic of); Dadfarnia, Shayessteh, E-mail: sdadfarnia@yazd.ac.ir [Department of Chemistry, Yazd University, Safaieh, 89195-741, Yazd (Iran, Islamic Republic of); Abbasi, Amir [Department of Physics, Yazd University, Safaieh, 89195-741, Yazd (Iran, Islamic Republic of); Rashidian Vaziri, Mohammad Reza [Laser and Optics Research School, 14155-1339, Tehran (Iran, Islamic Republic of); Behjat, Abbas [Department of Physics, Yazd University, Safaieh, 89195-741, Yazd (Iran, Islamic Republic of)

    2016-01-28

    This study aims at developing a novel, sensitive, fast, simple and convenient method for separation and preconcentration of trace amounts of fluoxetine before its spectrophotometric determination. The method is based on combination of magnetic mixed hemimicelles solid phase extraction and dispersive micro solid phase extraction using 1-hexadecyl-3-methylimidazolium bromide coated magnetic graphene as a sorbent. The magnetic graphene was synthesized by a simple coprecipitation method and characterized by X-ray diffraction (XRD), Fourier transform infrared (FT-IR) spectroscopy and scanning electron microscopy (SEM). The retained analyte was eluted using a 100 μL mixture of methanol/acetic acid (9:1) and converted into fluoxetine-β-cyclodextrin inclusion complex. The analyte was then quantified by fiber optic linear array spectrophotometry as well as mode-mismatched thermal lens spectroscopy (TLS). The factors affecting the separation, preconcentration and determination of fluoxetine were investigated and optimized. With a 50 mL sample and under optimized conditions using the spectrophotometry technique, the method exhibited a linear dynamic range of 0.4–60.0 μg L{sup −1}, a detection limit of 0.21 μg L{sup −1}, an enrichment factor of 167, and a relative standard deviation of 2.1% and 3.8% (n = 6) at 60 μg L{sup −1} level of fluoxetine for intra- and inter-day analyses, respectively. However, with thermal lens spectrometry and a sample volume of 10 mL, the method exhibited a linear dynamic range of 0.05–300 μg L{sup −1}, a detection limit of 0.016 μg L{sup −1} and a relative standard deviation of 3.8% and 5.6% (n = 6) at 60 μg L{sup −1} level of fluoxetine for intra- and inter-day analyses, respectively. The method was successfully applied to determine fluoxetine in pharmaceutical formulation, human urine and environmental water samples. - Graphical abstract: A novel, sensitive, fast, simple and convenient mixed hemimicelles

  2. Intraocular lens fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, Mike A. (Albuquerque, NM); Foreman, Larry R. (Los Alamos, NM)

    1997-01-01

    This invention describes a method for fabricating an intraocular lens made rom clear Teflon.TM., Mylar.TM., or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube.

  3. Intraocular lens fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, M.A.; Foreman, L.R.

    1997-07-08

    This invention describes a method for fabricating an intraocular lens made from clear Teflon{trademark}, Mylar{trademark}, or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube. 13 figs.

  4. Effect of micro-nano-hybrid structured hydroxyapatite bioceramics on osteogenic and cementogenic differentiation of human periodontal ligament stem cell via Wnt signaling pathway

    Directory of Open Access Journals (Sweden)

    Mao LX

    2015-11-01

    Full Text Available Lixia Mao,1,* Jiaqiang Liu,1,* Jinglei Zhao,1 Jiang Chang,2 Lunguo Xia,1 Lingyong Jiang,1 Xiuhui Wang,2 Kaili Lin,2,3 Bing Fang11Center of Craniofacial Orthodontics, Department of Oral and Cranio-maxillofacial Science, Top Priority Clinical Medical Center of Shanghai Municipal Commission of Health and Family Planning, Ninth People’s Hospital Affiliated to Shanghai Jiao Tong University, School of Medicine, Shanghai Jiao Tong University, 2State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, 3Shanghai Engineering Research Center of Tooth Restoration and Regeneration, School of Stomatology, Tongji University, Shanghai, People’s Republic of China*These authors contributed equally to this workAbstract: The surface structure of bioceramic scaffolds is crucial for its bioactivity and osteoinductive ability, and in recent years, human periodontal ligament stem cells have been certified to possess high osteogenic and cementogenic differential ability. In the present study, hydroxyapatite (HA bioceramics with micro-nano-hybrid surface (mnHA [the hybrid of nanorods and microrods] were fabricated via hydrothermal reaction of the α-tricalcium phosphate granules as precursors in aqueous solution, and the effects of mnHA on the attachment, proliferation, osteogenic and cementogenic differentiations of human periodontal ligament stem cells as well as the related mechanisms were systematically investigated. The results showed that mnHA bioceramics could promote cell adhesion, proliferation, alkaline phosphatase (ALP activity, and expression of osteogenic/cementogenic-related markers including runt-related transcription factor 2 (Runx2, ALP, osteocalcin (OCN, cementum attachment protein (CAP, and cementum protein (CEMP as compared to the HA bioceramics with flat and dense surface. Moreover, mnHA bioceramics stimulated gene expression of low-density lipoprotein receptor

  5. Analytic models of plausible gravitational lens potentials

    International Nuclear Information System (INIS)

    Baltz, Edward A.; Marshall, Phil; Oguri, Masamune

    2009-01-01

    Gravitational lenses on galaxy scales are plausibly modelled as having ellipsoidal symmetry and a universal dark matter density profile, with a Sérsic profile to describe the distribution of baryonic matter. Predicting all lensing effects requires knowledge of the total lens potential: in this work we give analytic forms for that of the above hybrid model. Emphasising that complex lens potentials can be constructed from simpler components in linear combination, we provide a recipe for attaining elliptical symmetry in either projected mass or lens potential. We also provide analytic formulae for the lens potentials of Sérsic profiles for integer and half-integer index. We then present formulae describing the gravitational lensing effects due to smoothly-truncated universal density profiles in cold dark matter model. For our isolated haloes the density profile falls off as radius to the minus fifth or seventh power beyond the tidal radius, functional forms that allow all orders of lens potential derivatives to be calculated analytically, while ensuring a non-divergent total mass. We show how the observables predicted by this profile differ from that of the original infinite-mass NFW profile. Expressions for the gravitational flexion are highlighted. We show how decreasing the tidal radius allows stripped haloes to be modelled, providing a framework for a fuller investigation of dark matter substructure in galaxies and clusters. Finally we remark on the need for finite mass halo profiles when doing cosmological ray-tracing simulations, and the need for readily-calculable higher order derivatives of the lens potential when studying catastrophes in strong lenses

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... Costume Contact Lenses Can Ruin Vision Eye Makeup Safety In fact, it is illegal to sell colored ...

  7. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... new application of artificial intelligence shows whether a patient’s eyes point to high blood pressure or risk ...

  8. The lens and cataracts.

    Science.gov (United States)

    Matthews, Andrew G

    2004-08-01

    It is conservatively estimated that some form of lens opacity is present in 5% to 7% of horses with otherwise clinically normal eyes.These opacities can range from small epicapsular remnants of the fetal vasculature to dense and extensive cataract. A cataract is defined technically as any opacity or alteration in the optical homogeneity of the lens involving one or more of the following: anterior epithelium, capsule, cortex, or nucleus. In the horse, cataracts rarely involve the entire lens structure (ie, complete cataracts) and are more usually localized to one anatomic landmark or sector of the lens. Complete cataracts are invariably associated with overt and significant visual disability. Focal or incomplete cataracts alone seldom cause any apparent visual dysfunction in affected horses,however.

  9. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses ...

  10. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her ...

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... contacto de color Sep. 26, 2013 It started as an impulsive buy from a souvenir shop, but ... require the same level of care or consideration as a standard contact lens because they can be ...

  12. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... With Proper Contact Lens Care Apr 23, 2018 Solar Eclipse Inflicts Damage in the Shape of the ... edging closer, thanks to a wave of new technologies aiming to fix failing eye parts with human- ...

  13. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... glow-in-the-dark lizard lenses, costume contacts can certainly add a spooky, eye-popping touch. But ... consideration as a standard contact lens because they can be purchased over-the-counter or on the ...

  14. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... valid prescription that includes the brand name, lens measurements, and expiration date. Purchase the colored contact lenses ... with human-made versions. U.S. News Highlights the Value of Ophthalmologists APR 20, 2018 By Dan T. ...

  15. Vortex gas lens

    Science.gov (United States)

    Bogdanoff, David W.; Berschauer, Andrew; Parker, Timothy W.; Vickers, Jesse E.

    1989-01-01

    A vortex gas lens concept is presented. Such a lens has a potential power density capability of 10 to the 9th - 10 to the 10th w/sq cm. An experimental prototype was constructed, and the divergence half angle of the exiting beam was measured as a function of the lens operating parameters. Reasonably good agreement is found between the experimental results and theoretical calculations. The expanded beam was observed to be steady, and no strong, potentially beam-degrading jets were found to issue from the ends of the lens. Estimates of random beam deflection angles to be expected due to boundary layer noise are presented; these angles are very small.

  16. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... had not been properly fitted by an eye care professional, the lenses stuck to my eye like ... lenses do not require the same level of care or consideration as a standard contact lens because ...

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ...

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms ...

  19. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... ask for a prescription. There is no such thing as a "one size fits all" contact lens. ...

  20. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. Follow the contact lens care directions for cleaning, disinfecting, and wearing the lenses. Never share contact ... with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  1. TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

    Energy Technology Data Exchange (ETDEWEB)

    Rehani, M. [Massachusetts General Hospital (United States)

    2015-06-15

    . These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the

  2. TU-E-201-03: Eye Lens Dosimetry in Radiotherapy Using Contact Lens-Shaped Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Park, J. [Seoul National University Hospital (Korea, Republic of)

    2015-06-15

    . These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the

  3. TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

    International Nuclear Information System (INIS)

    Rehani, M.

    2015-01-01

    . These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the

  4. TU-E-201-03: Eye Lens Dosimetry in Radiotherapy Using Contact Lens-Shaped Applicator

    International Nuclear Information System (INIS)

    Park, J.

    2015-01-01

    . These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the

  5. Symmetric lens with extended depth of focus

    OpenAIRE

    Cho, Sung Nae

    2008-01-01

    The lens surface profile is derived based on the instantaneous focal length versus the lens radius data. The lens design based on instantaneous focal length versus the lens radius data has many useful applications in software assisted image focusing technology.

  6. A catoptric lens

    International Nuclear Information System (INIS)

    Rambauske, W.R.

    1973-01-01

    The invention relates to a catoptric lens for combining energies transmitted by several sources such as lasers; said lens comprising mirrors, the reflective surfaces of which have their focuses spaced from a common axis of symmetry. By means of these reflecting surfaces, which are generated by the nutation of portions of quadratic conics about the axis of symmetry, it is possible to focus the energy emmited by several lasers at the focus of the exit-mirror reflecting surface. This can be applied to thermonuclear fusion [fr

  7. Active liquid-crystal deflector and lens with Fresnel structure

    Science.gov (United States)

    Shibuya, Giichi; Yamano, Shohei; Yoshida, Hiroyuki; Ozaki, Masanori

    2017-02-01

    A new type of tunable Fresnel deflector and lens composed of liquid crystal was developed. Combined structure of multiple interdigitated electrodes and the high-resistivity (HR) layer implements the saw-tooth distribution of electrical potential with only the planar surfaces of the transparent substrates. According to the numerical calculation and design, experimental devices were manufactured with the liquid crystal (LC) material sealed into the sandwiched flat glass plates of 0.7 mm thickness with rubbed alignment layers set to an anti-parallel configuration. Fabricated beam deflector with no moving parts shows the maximum tilt angle of +/-1.3 deg which can apply for optical image stabilizer (OIS) of micro camera. We also discussed and verified their lens characteristics to be extended more advanced applications. Transparent interdigitated electrodes were concentrically aligned on the lens aperture with the insulator gaps under their boundary area. The diameter of the lens aperture was 30 mm and the total number of Fresnel zone was 100. Phase retardation of the beam wavefront irradiated from the LC lens device can be evaluated by polarizing microscope images with a monochromatic filter. Radial positions of each observed fringe are plotted and fitted with 2nd degree polynomial approximation. The number of appeared fringes is over 600 in whole lens aperture area and the correlation coefficients of all approximations are over 0.993 that seems enough ideal optical wavefront. The obtained maximum lens powers from the approximations are about +/-4 m-1 which was satisfied both convex and concave lens characteristics; and their practical use for the tunable lens grade eyeglasses became more prospective.

  8. LC-lens array with light field algorithm for 3D biomedical applications

    Science.gov (United States)

    Huang, Yi-Pai; Hsieh, Po-Yuan; Hassanfiroozi, Amir; Martinez, Manuel; Javidi, Bahram; Chu, Chao-Yu; Hsuan, Yun; Chu, Wen-Chun

    2016-03-01

    In this paper, liquid crystal lens (LC-lens) array was utilized in 3D bio-medical applications including 3D endoscope and light field microscope. Comparing with conventional plastic lens array, which was usually placed in 3D endoscope or light field microscope system to record image disparity, our LC-lens array has higher flexibility of electrically changing its focal length. By using LC-lens array, the working distance and image quality of 3D endoscope and microscope could be enhanced. Furthermore, the 2D/3D switching ability could be achieved if we turn off/on the electrical power on LClens array. In 3D endoscope case, a hexagonal micro LC-lens array with 350um diameter was placed at the front end of a 1mm diameter endoscope. With applying electric field on LC-lens array, the 3D specimen would be recorded as from seven micro-cameras with different disparity. We could calculate 3D construction of specimen with those micro images. In the other hand, if we turn off the electric field on LC-lens array, the conventional high resolution 2D endoscope image would be recorded. In light field microscope case, the LC-lens array was placed in front of the CMOS sensor. The main purpose of LC-lens array is to extend the refocusing distance of light field microscope, which is usually very narrow in focused light field microscope system, by montaging many light field images sequentially focusing on different depth. With adjusting focal length of LC-lens array from 2.4mm to 2.9mm, the refocusing distance was extended from 1mm to 11.3mm. Moreover, we could use a LC wedge to electrically shift the optics axis and increase the resolution of light field.

  9. A Tribute to Len Barton

    Science.gov (United States)

    Tomlinson, Sally

    2010-01-01

    This article constitutes a short personal tribute to Len Barton in honour of his work and our collegial relationship going back over 30 years. It covers how Len saw his intellectual project of providing critical sociological and political perspectives on special education, disability and inclusion, and his own radical political perspectives. Len's…

  10. Luneburg lens in silicon photonics.

    Science.gov (United States)

    Di Falco, Andrea; Kehr, Susanne C; Leonhardt, Ulf

    2011-03-14

    The Luneburg lens is an aberration-free lens that focuses light from all directions equally well. We fabricated and tested a Luneburg lens in silicon photonics. Such fully-integrated lenses may become the building blocks of compact Fourier optics on chips. Furthermore, our fabrication technique is sufficiently versatile for making perfect imaging devices on silicon platforms.

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. There is no such thing as a "one size fits all" contact lens. Lenses that are not properly fitted may scratch the eye or cause blood vessels to grow into the cornea. Even if you have perfect vision, you need to get an eye exam and a prescription ...

  12. Contact Lens Risks

    Science.gov (United States)

    ... There is a risk of eye infection from bacteria in swimming pool water, hot tubs, lakes and the ocean Replace your contact lens storage case every 3 months or as directed by your eye care professional. Other Risks of Contact Lenses Other risks of contact lenses include pink eye ( ...

  13. MISSING: BUBBLE CHAMBER LENS

    CERN Multimedia

    2001-01-01

    Would the person who borrowed the large bubble chamber lens from the Microcosm workshops on the ISR please return it. This is a much used piece from our object archives. If anybody has any information about the whereabouts of this object, please contact Emma.Sanders@cern.ch Thank you

  14. The Lens of Chemistry

    Science.gov (United States)

    Thalos, Mariam

    2013-01-01

    Chemistry possesses a distinctive theoretical lens--a distinctive set of theoretical concerns regarding the dynamics and transformations of a perplexing variety of organic and nonorganic substances--to which it must be faithful. Even if it is true that chemical facts bear a special (reductive) relationship to physical facts, nonetheless it will…

  15. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her with a corneal ... A recent article from U.S. News and World Report explains what ophthalmologists are and how they can ...

  16. Quadrupole magnetic lens

    International Nuclear Information System (INIS)

    Piskunov, V.A.

    1981-01-01

    The following connection of windings of electromagnet is suggested for simplification of the design of qUadrupole magnetic lens intended for use in radiotechnical and electron-optical devices. The mentioned windings are connected with each other by a bridge scheme and the variable resistors are switched in its diagonals in the lens containing four electromagnet with windings connected with two variable resistors the mobile contacts of which are connected with a direct current source. Current redistribution between left windings and right windings takes place at shift of mobile contact of variable resistor, and current redistribution between upper and low coils of electromagnets takes place at shifting mobile contact of the other variable resistor. In this case smooth and independent electron-optical misalignment of lens by two mutually perpendicular directions proceeds. Use of the given design of the lens in the oscillograph permits to use printing assembly for alignment plate and to reduce the number of connections at the expense of decreasing the number of resistors

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... can be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... ask for a prescription. There is no such thing as a "one size fits all" contact lens. Lenses that are not properly fitted may scratch the eye or cause blood vessels to grow into ...

  18. Review of Micro Magnetic Generator

    OpenAIRE

    Lin DU; Gengchen SHI; Jingjing ZHAO

    2014-01-01

    This paper discusses the research progress of micro magnetic generator systems. Micro magnetic generator systems convert energy from the environment to electric energy with advantages as high reliability, high power density, long life time and can be applied to extreme environment. This paper summarizes methods for improving generator performance of micro magnetic generator, including rotational magnetic generator, vibrational magnetic generator and hybrid magnetic generator, analyzes and com...

  19. A Correlation of Thin Lens Approximation to Thick Lens Design by Using Coddington Factors in Lens Design and Manufacturing

    OpenAIRE

    FARSAKOĞLU, Ö. Faruk

    2014-01-01

    The effect of Coddington factors on aberration functions has been analysed using thin lens approximation. Minimizing spherical aberrations of singlet lenses using Coddington factors in lens design depending on lens manufacturing is discussed. Notation of lens test plate pairs used in lens manufacturing is also presented in terms of Coddington shape factors.

  20. Angular dependant micro-ESR characterization of a locally doped Gd3+:Al2O3 hybrid system for quantum applications

    Science.gov (United States)

    Wisby, I. S.; de Graaf, S. E.; Gwilliam, R.; Adamyan, A.; Kubatkin, S. E.; Meeson, P. J.; Tzalenchuk, A. Ya.; Lindstrom, T.

    Rare-earth doped crystals interfaced with superconducting quantum circuitry are an attractive platform for quantum memory and transducer applications. Here we present a detailed characterization of a locally implanted Gd3+ in Al2O3 system coupled to a superconducting micro-resonator, by performing angular dependent micro-electron-spin-resonance (micro-ESR) measurements at mK temperatures. The device is fabricated using a hard Si3N4 mask to facilitate a local ion-implantation technique for precision control of the dopant location. The technique is found not to degrade the internal quality factor of the resonators which remains above 105 (1). We find the measured angular dependence of the micro-ESR spectra to be in excellent agreement with the modelled Hamiltonian, supporting the conclusion that the dopant ions are successfully integrated into their relevant lattice sites whilst maintaining crystalline symmetries. Furthermore, we observe clear contributions from individual microwave field components of our micro-resonator, emphasising the need for controllable local implantation. 1 Wisby et al. Appl. Phys. Lett. 105, 102601 (2014)

  1. Integration of micro milling highspeed spindle on a microEDM-milling machine set-up

    DEFF Research Database (Denmark)

    De Grave, Arnaud; Hansen, Hans Nørgaard; Andolfatto, Loic

    2009-01-01

    In order to cope with repositioning errors and to combine the fast removal rate of micro milling with the precision and small feature size achievable with micro EDM milling, a hybrid micro-milling and micro-EDM milling centre was built and tested. The aim was to build an affordable set-up, easy...... by micro milling. Examples of test parts are shown and used as an experimental validation....

  2. Hybrid micro/nano-topography of a TiO2 nanotube-coated commercial zirconia femoral knee implant promotes bone cell adhesion in vitro.

    Science.gov (United States)

    Frandsen, Christine J; Noh, Kunbae; Brammer, Karla S; Johnston, Gary; Jin, Sungho

    2013-07-01

    Various approaches have been studied to engineer the implant surface to enhance bone in-growth properties, particularly using micro- and nano-topography. In this study, the behavior of osteoblast (bone) cells was analyzed in response to a titanium oxide (TiO2) nanotube-coated commercial zirconia femoral knee implant consisting of a combined surface structure of a micro-roughened surface with the nanotube coating. The osteoblast cells demonstrated high degrees of adhesion and integration into the surface of the nanotube-coated implant material, indicating preferential cell behavior on this surface when compared to the bare implant. The results of this brief study provide sufficient evidence to encourage future studies. The development of such hierarchical micro- and nano-topographical features, as demonstrated in this work, can provide insightful designs for advanced bone-inducing material coatings on ceramic orthopedic implant surfaces. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Aero-acoustics noise assessment for Wind-Lens turbine

    International Nuclear Information System (INIS)

    Hashem, I.; Mohamed, M.H.; Hafiz, A.A.

    2017-01-01

    This paper introduces an aero-acoustic computational study that investigates the noise caused by one of the most promising wind energy conversion concepts, namely the 'Wind-Lens' technology. The hybrid method - where the flow field and acoustic field are solved separately, was deemed to be an appropriate tool to compute this study. The need to investigate this phenomenon increased gradually, since the feasibility of utilizing Wind-Lens turbine within densely populated cities and urban areas depends largely on their noise generation. Ffowcs Williams-Hawkings (FW-H) equation and its integral solution are used to predict the noise radiating to the farfield. CFD Simulations of transient three-dimensional flow field using (URANS) unsteady Reynolds-averaged Navier-Stokes equations are computed to acquire the acoustic sources location and sound intensity. Then, the noise propagates from the before-mentioned sources to pre-defined virtual microphones positioned in different locations. ANSYS-FLUENT is used to calculate the flow field on and around such turbines which is required for the FW-H code. Some effective parameters are investigated such as Wind-Lens shape, brim height and tip speed ratio. Comparison of the noise emitted from the bare wind turbine and different types of Wind-Lens turbine reveals that, the Wind-Lens generates higher noise intensity. - Highlights: • Aero-acoustic noise generated by wind turbines are one of the major challenges. • Noise from wind turbine equipped with a brimmed diffuser is investigated. • A computational aero-acoustic study using the hybrid method is introduced. • Effective parameters are studied such Wind-Lens shape, brim height and speed ratio. • The optimal shape has a moderate power coefficient and the less noise generation.

  4. Flexible micro flow sensor for micro aerial vehicles

    Science.gov (United States)

    Zhu, Rong; Que, Ruiyi; Liu, Peng

    2017-12-01

    This article summarizes our studies on micro flow sensors fabricated on a flexible polyimide circuit board by a low-cost hybrid process of thin-film deposition and circuit printing. The micro flow sensor has merits of flexibility, structural simplicity, easy integrability with circuits, and good sensing performance. The sensor, which adheres to an object surface, can detect the surface flow around the object. In our study, we install the fabricated micro flow sensors on micro aerial vehicles (MAVs) to detect the surface flow variation around the aircraft wing and deduce the aerodynamic parameters of the MAVs in flight. Wind tunnel experiments using the sensors integrated with the MAVs are also conducted.

  5. Hybrid mask for deep etching

    KAUST Repository

    Ghoneim, Mohamed T.

    2017-01-01

    Deep reactive ion etching is essential for creating high aspect ratio micro-structures for microelectromechanical systems, sensors and actuators, and emerging flexible electronics. A novel hybrid dual soft/hard mask bilayer may be deposited during

  6. Retinal images in the human eye with implanted intraocular lens

    Science.gov (United States)

    Zając, Marek; Siedlecki, Damian; Nowak, Jerzy

    2007-04-01

    A typical proceeding in cataract is based on the removal of opaque crystalline lens and inserting in its place the artificial intraocular lens (IOL). The quality of retinal image after such procedure depends, among others, on the parameters of the IOL, so the design of the implanted lens is of great importance. An appropriate choice of the IOL material, especially in relation to its biocompatibility, is often considered. However the parameter, which is often omitted during the IOL design is its chromatic aberration. In particular lack of its adequacy to the chromatic aberration of a crystalline lens may cause problems. In order to fit better chromatic aberration of the eye with implanted IOL to that of the healthy eye we propose a hybrid - refractive-diffractive IOL. It can be designed in such way that the total longitudinal chromatic aberration of an eye with implanted IOL equals the total longitudinal chromatic aberration of a healthy eye. In this study we compare the retinal image quality calculated numerically on the basis of the well known Liou-Brennan eye model with typical IOL implanted with that obtained if the IOL is done as hybrid (refractive-diffractive) design.

  7. All-solid state, flexible, high-energy integrated hybrid micro-supercapacitors based on 3D LSG/CoNi2S4 nanosheets.

    Science.gov (United States)

    Moosavifard, Seyyed Ebrahim; Shamsi, Javad; Altafi, Mohammad Kazem; Moosavifard, Zeinab Sadat

    2016-11-18

    3D LSG/CoNi 2 S 4 //LSG interdigitated microelectrodes have been firstly developed by a facile, scalable and low cost process for all-solid-state, flexible integrated asymmetric micro-supercapacitors. These devices can achieve energy densities of up to 49 W h l -1 which is comparable to those of lead acid batteries.

  8. New lens system using toroidal magnetic field for intense ion beam

    International Nuclear Information System (INIS)

    Mohri, Akihiro; Ikuta, Kazunari; Fujita, Junji.

    1976-11-01

    The use of toroidal magnetic field as a lens system is proposed for producing intense ion beam. The characteristics of the lens system are obtained both analytically and numerically. Some examples of ray-trajectories are presented for different focal lengths. The system is applicable to neutral beam injection heating and micro-pellet implosion for nuclear fusion, and to the other fields such as ion beam X-ray lasers. (auth.)

  9. An all-silicone zoom lens in an optical imaging system

    International Nuclear Information System (INIS)

    Zhao Cun-Hua

    2013-01-01

    An all-silicone zoom lens is fabricated. A tunable metal ringer is fettered around the side edge of the lens. A nylon rope linking a motor is tied, encircling the notch in the metal ringer. While the motor is operating, the rope can shrink or release to change the focal length of the lens. A calculation method is developed to obtain the focal length and the zoom ratio. The testing is carried out in succession. The testing values are compared with the calculated ones, and they tally with each other well. Finally, the imaging performance of the all-silicone lens is demonstrated. The all-silicone lens has potential uses in cellphone cameras, notebook cameras, micro monitor lenses, etc. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  10. An all-silicone zoom lens in an optical imaging system

    Science.gov (United States)

    Zhao, Cun-Hua

    2013-09-01

    An all-silicone zoom lens is fabricated. A tunable metal ringer is fettered around the side edge of the lens. A nylon rope linking a motor is tied, encircling the notch in the metal ringer. While the motor is operating, the rope can shrink or release to change the focal length of the lens. A calculation method is developed to obtain the focal length and the zoom ratio. The testing is carried out in succession. The testing values are compared with the calculated ones, and they tally with each other well. Finally, the imaging performance of the all-silicone lens is demonstrated. The all-silicone lens has potential uses in cellphone cameras, notebook cameras, micro monitor lenses, etc.

  11. A field operational test on valve-regulated lead-acid absorbent-glass-mat batteries in micro-hybrid electric vehicles. Part I. Results based on kernel density estimation

    Science.gov (United States)

    Schaeck, S.; Karspeck, T.; Ott, C.; Weckler, M.; Stoermer, A. O.

    2011-03-01

    In March 2007 the BMW Group has launched the micro-hybrid functions brake energy regeneration (BER) and automatic start and stop function (ASSF). Valve-regulated lead-acid (VRLA) batteries in absorbent glass mat (AGM) technology are applied in vehicles with micro-hybrid power system (MHPS). In both part I and part II of this publication vehicles with MHPS and AGM batteries are subject to a field operational test (FOT). Test vehicles with conventional power system (CPS) and flooded batteries were used as a reference. In the FOT sample batteries were mounted several times and electrically tested in the laboratory intermediately. Vehicle- and battery-related diagnosis data were read out for each test run and were matched with laboratory data in a data base. The FOT data were analyzed by the use of two-dimensional, nonparametric kernel estimation for clear data presentation. The data show that capacity loss in the MHPS is comparable to the CPS. However, the influence of mileage performance, which cannot be separated, suggests that battery stress is enhanced in the MHPS although a battery refresh function is applied. Anyway, the FOT demonstrates the unsuitability of flooded batteries for the MHPS because of high early capacity loss due to acid stratification and because of vanishing cranking performance due to increasing internal resistance. Furthermore, the lack of dynamic charge acceptance for high energy regeneration efficiency is illustrated. Under the presented FOT conditions charge acceptance of lead-acid (LA) batteries decreases to less than one third for about half of the sample batteries compared to new battery condition. In part II of this publication FOT data are presented by multiple regression analysis (Schaeck et al., submitted for publication [1]).

  12. Efectividad de la lente intraocular ACRI. SMART 46-S en la cirugía de catarata por microincisiones Effectiveness of the intraocular lens ACRI SMART 46-S in micro-incision cataract surgery

    Directory of Open Access Journals (Sweden)

    Juan Raúl Hernández Silva

    2007-12-01

    catarata, también permitiría desarrollar en el futuro materiales y tecnologías que abrirían nuevos caminos para la cirugía oftalmológica, y la aplicación de parámetros facodinámicos óptimos conllevaría a un bajo porcentaje de complicaciones.Improvement and application of an industry devoted to modernize intraocular lenses and surgical tools have prompted a set of advances that allow optimizing, correcting and refining the surgical techniques for cataract surgery, particularly phacoemulsification. The most important aspect in this chain of advacements is aimed at reducing the surgical incision size in order to avoid a significant number of complications that are relatively frequent when using conventional extracapsular and intracapsular surgeries with over 10mm incisions. At present, new surgical techniques such as microincision cataract surgery have been developed. A retrospective and descriptive study was performed in 27 patients (eyes diagnosed with pre-senile and senile cataract, who were surgically treated with microincision phacoemulsification and received the implant of an ACRi Smart 46.S 11 x 6mm acrylic intraocular lens in the posterior chamber at the Ocular Microsurgery Center of “Ramón Pando Ferrer” Ophthalmology Institute in the period from January 2004 to January 2005. It was found that most of cases were older than 50 years; the best corrected visual acuity recovered significantly in the postoperative period and induced astigmatism was low. Regarding the used phacodynamic parameters, the ultrasound power was generally low. There were few complications, being vitreous detachment secondary to break in the posterior capsule. It was concluded that microincision cataract surgery with Acri Smart 46 S lens implant is a valid, safe and effective choice of catract treatment that will allow developing in the future materials and technologies which would open up new paths for eye surgery, and also the use of optimal phacodynamic parameters would lead to a

  13. Micro Engineering

    DEFF Research Database (Denmark)

    Alting, Leo; Kimura, F.; Hansen, Hans Nørgaard

    2003-01-01

    The paper addresses the questions of how micro products are designed and how they are manufactured. Definitions of micro products and micro engineering are discussed and the presentation is aimed at describing typical issues, possibilities and tools regarding design of micro products. The implica......The paper addresses the questions of how micro products are designed and how they are manufactured. Definitions of micro products and micro engineering are discussed and the presentation is aimed at describing typical issues, possibilities and tools regarding design of micro products...

  14. Characteristics of the thick, compound refractive lens

    International Nuclear Information System (INIS)

    Pantell, Richard H.; Feinstein, Joseph; Beguiristain, H. Raul; Piestrup, Melvin A.; Gary, Charles K.; Cremer, Jay T.

    2003-01-01

    A compound refractive lens (CRL), consisting of a series of N closely spaced lens elements each of which contributes a small fraction of the total focusing, can be used to focus x rays or neutrons. The thickness of a CRL can be comparable to its focal length, whereupon a thick-lens analysis must be performed. In contrast with the conventional optical lens, where the ray inside the lens follows a straight line, the ray inside the CRL is continually changing direction because of the multiple refracting surfaces. Thus the matrix representation for the thick CRL is quite different from that for the thick optical lens. Principal planes can be defined such that the thick-lens matrix can be converted to that of a thin lens. For a thick lens the focal length is greater than for a thin lens with the same lens curvature, but this lengthening effect is less for the CRL than for the conventional optical lens

  15. Design method of freeform light distribution lens for LED automotive headlamp based on DMD

    Science.gov (United States)

    Ma, Jianshe; Huang, Jianwei; Su, Ping; Cui, Yao

    2018-01-01

    We propose a new method to design freeform light distribution lens for light-emitting diode (LED) automotive headlamp based on digital micro mirror device (DMD). With the Parallel optical path architecture, the exit pupil of the illuminating system is set in infinity. Thus the principal incident rays of micro lens in DMD is parallel. DMD is made of high speed digital optical reflection array, the function of distribution lens is to distribute the emergent parallel rays from DMD and get a lighting pattern that fully comply with the national regulation GB 25991-2010.We use DLP 4500 to design the light distribution lens, mesh the target plane regulated by the national regulation GB 25991-2010 and correlate the mesh grids with the active mirror array of DLP4500. With the mapping relations and the refraction law, we can build the mathematics model and get the parameters of freeform light distribution lens. Then we import its parameter into the three-dimensional (3D) software CATIA to construct its 3D model. The ray tracing results using Tracepro demonstrate that the Illumination value of target plane is easily adjustable and fully comply with the requirement of the national regulation GB 25991-2010 by adjusting the exit brightness value of DMD. The theoretical optical efficiencies of the light distribution lens designed using this method could be up to 92% without any other auxiliary lens.

  16. Crystalline lens radioprotectors

    International Nuclear Information System (INIS)

    Belkacemi, Y.; Pasquier, D.; Castelain, B.; Lartigau, E.; Warnet, J.M.

    2003-01-01

    During more than a half of century, numerous compounds have been tested in different models against radiation-induced cataract. In this report, we will review the radioprotectors that have been already tested for non-human crystalline lens protection. We will focus on the most important published studies in this topic and the mechanisms of cyto-protection reported in. vitro and in. vivo from animals. The most frequent mechanisms incriminated in the cyto-protective effect are: free radical scavenging, limitation of lipid peroxidation, modulation of cycle progression increase of intracellular reduced glutathione pool, reduction of DNA strand breaks and limitation of apoptotic cell death. Arnifostine (or Ethyol) and anethole dithiolethione (or Sulfarlem), already used clinically as chemo- and radio-protectants, could be further test?r for ocular radioprotection particularly for radiation-induced cataract. (author)

  17. Wedged multilayer Laue lens

    International Nuclear Information System (INIS)

    Conley, Ray; Liu Chian; Qian Jun; Kewish, Cameron M.; Macrander, Albert T.; Yan Hanfei; Maser, Joerg; Kang, Hyon Chol; Stephenson, G. Brian

    2008-01-01

    A multilayer Laue lens (MLL) is an x-ray focusing optic fabricated from a multilayer structure consisting of thousands of layers of two different materials produced by thin-film deposition. The sequence of layer thicknesses is controlled to satisfy the Fresnel zone plate law and the multilayer is sectioned to form the optic. An improved MLL geometry can be created by growing each layer with an in-plane thickness gradient to form a wedge, so that every interface makes the correct angle with the incident beam for symmetric Bragg diffraction. The ultimate hard x-ray focusing performance of a wedged MLL has been predicted to be significantly better than that of a nonwedged MLL, giving subnanometer resolution with high efficiency. Here, we describe a method to deposit the multilayer structure needed for an ideal wedged MLL and report our initial deposition results to produce these structures

  18. Visualization of transverse diffusion paths across fiber cells of the ocular lens by small animal MRI

    International Nuclear Information System (INIS)

    Vaghefi, Ehsan; Hunter, Peter J; Jacobs, Marc D; Pontre, Beau; Donaldson, Paul J

    2009-01-01

    The sense of vision requires that light penetrate through the ocular lens. Experiments, performed and published by many research groups, have suggested that the lens, which has no blood vessels, relies on internally directed ion and water fluxes for its circulation, survival and transparency. We investigated the internal diffusive pathways of the lens in order to better understand the constraints that may be operating on directional lens fluxes. Small animal magnetic resonance imaging, including T2-weighted and diffusion tensor imaging, was used to measure tissue properties and diffusivity throughout cultured bovine lenses. A range of concentric regions of signal intensity was distinguished inside the lens, by both T2-weighted signal and mean diffusivity. Diffusivity mapping of the lens revealed novel anisotropic polar and equatorial zones of pronounced diffusivity directed transverse to the fiber cells. In contrast, an inner zone including the lens nucleus showed isotropic and weak diffusivity. Our results lend support to models of internally directed lens micro-circulation, by placing non-structural diffusive constraints on global patterns of fluid circulation

  19. Locked Nucleic Acid-Based In Situ Hybridization Reveals miR-7a as a Hypothalamus-Enriched MicroRNA with a Distinct Expression Pattern

    DEFF Research Database (Denmark)

    Herzer, S; Silahtaroglu, A; Meister, B

    2012-01-01

    , a part of the brain that controls vital bodily functions, we employed locked nucleic acid (LNA) - fluorescent in situ hybridization (FISH). The expression pattern of the mature miRNAs miR-7a, miR-7b, miR-137 and miR-153 in mouse brain tissue sections was investigated. Whereas all studied miRNAs were......R-7a expression was particularly prominent in the subfornical organ, suprachiasmatic, paraventricular, periventricular, supraoptic, dorsomedial and arcuate nuclei. Identical expression patterns for miR-7a was seen in mouse and rat hypothalamus. By combining LNA-FISH with immunohistochemistry...

  20. Compliance among soft contact lens wearers.

    Science.gov (United States)

    Kuzman, Tomislav; Kutija, Marija Barisić; Masnec, Sanja; Jandroković, Sonja; Mrazovac, Danijela; Jurisić, Darija; Skegro, Ivan; Kalauz, Miro; Kordić, Rajko

    2014-12-01

    Contact lens compliance is proven to be crucial for preventing lens wear-related complications because of the interdependence of the steps in lens care regime and their influence on lens system microbial contamination. Awareness of the patients' lens handling compliance as well as correct recognition of non-compliant behaviours is the basis for creating more targeted strategies for patient education. The aim of this study was to investigate compliance among soft contact lens (SCL) wearers in different aspects of lens care handling and wearing habits. In our research 50 asymptomatic lens wearers filled out a questionnaire containing demographic data, lens type, hygiene and wearing habits, lenses and lens care system replacement schedule and self-evaluation of contact lens handling hygiene. We established criteria of compliance according to available manufacturer's recommendations, prior literature and our clinical experience. Only 2 (4%) of patients were fully compliant SCL wearers. The most common non-compliant behaviours were insufficient lens solution soaking time (62%), followed by failure to daily exchange lens case solution and showering while wearing lenses. 44% of patients reported storing lenses in saline solution. Mean lens storage case replacement was 3.6 months, with up to 78% patients replacing lens case at least once in 3 months. Average grade in self evaluating level of compliance was very good (4 +/- 0.78) (from 1-poor level of hygiene to 5-great level of hygiene). Lens wearers who reported excessive daily lens wear and more than 10 years of lens wearing experience were also found to be less compliant with other lens system care procedures. (t = -2.99, df=47, p rate, self grading was relatively high. Therefore, these results indicate the need for patient education and encouragement of better lens wearing habits and all of the lens maintenance steps at each patient visit.

  1. Contact Lens-Related Eye Infections

    Science.gov (United States)

    ... Español Eye Health / Eye Health A-Z Contact Lens-Related Eye Infections Sections Contact Lens-Related Eye ... Six Steps to Avoid Contact Lens Infections Contact Lens-Related Eye Infections Leer en Español: Infecciones relacionadas ...

  2. 21 CFR 886.1375 - Bagolini lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bagolini lens. 886.1375 Section 886.1375 Food and... OPHTHALMIC DEVICES Diagnostic Devices § 886.1375 Bagolini lens. (a) Identification. A Bagolini lens is a device that consists of a plane lens containing almost imperceptible striations that do not obscure...

  3. Straylight Measurements in Contact Lens Wear

    NARCIS (Netherlands)

    van der Meulen, Ivanka J. E.; Engelbrecht, Leonore A.; van Vliet, Johannes M. J.; Lapid-Gortzak, Ruth; Nieuwendaal, Carla P.; Mourits, Maarten P.; Schlingemann, Reinier O.; van den Berg, Thomas J. T. P.

    2010-01-01

    Purpose: (1) To quantify the effect of contact lens wear on straylight in rigid and soft contact lens wearers and (2) to relate findings to morphological changes and subjective complaints. Methods: Straylight was measured using the Oculus C-Quant during contact lens wear and after contact lens

  4. Dual-Band Modulation of Visible and Near-Infrared Light Transmittance in an All-Solution-Processed Hybrid Micro-Nano Composite Film.

    Science.gov (United States)

    Liang, Xiao; Chen, Mei; Guo, Shumeng; Zhang, Lanying; Li, Fasheng; Yang, Huai

    2017-11-22

    Smart windows with controllable visible and near-infrared light transmittance can significantly improve the building's energy efficiency and inhabitant comfort. However, most of the current smart window technology cannot achieve the target of ideal solar control. Herein, we present a novel all-solution-processed hybrid micronano composite smart material that have four optical states to separately modulate the visible and NIR light transmittance through voltage and temperature, respectively. This dual-band optical modulation was achieved by constructing a phase-separated polymer framework, which contains the microsized liquid crystals domains with a negative dielectric constant and tungsten-doped vanadium dioxide (W-VO 2 ) nanocrystals (NCs). The film with 2.5 wt % W-VO 2 NCs exhibits transparency at normal condition, and the passage of visible light can be reversibly and actively regulated between 60.8% and 1.3% by external applied voltage. Also, the transmittance of NIR light can be reversibly and passively modulated between 59.4% and 41.2% by temperature. Besides, the film also features easy all-solution processability, fast electro-optical (E-O) response time, high mechanical strength, and long-term stability. The as-prepared film provides new opportunities for next-generation smart window technology, and the proposed strategy is conductive to engineering novel hybrid inorganic-organic functional matters.

  5. Immunohistochemical studies of lens crystallins in the dysgenetic lens (dyl) mutant mice

    NARCIS (Netherlands)

    Brahma, S.K.; Sanyal, S.

    1984-01-01

    The lens in the dyl mutant mice shows a persistent lens-ectodermal connection as well as degeneration and extrusion of lens materials after the initial differentiation of the fibres. Immunohistochemical investigation of the ontogeny of the lens crystallins in this developing mutant lens has been

  6. Contact Lens Related Corneal Ulcer

    OpenAIRE

    Loh, KY; Agarwal, P

    2010-01-01

    A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are: overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. Th...

  7. Crystalline lens and refractive development.

    Science.gov (United States)

    Iribarren, Rafael

    2015-07-01

    Individual refractive errors usually change along lifespan. Most children are hyperopic in early life. This hyperopia is usually lost during growth years, leading to emmetropia in adults, but myopia also develops in children during school years or during early adult life. Those subjects who remain emmetropic are prone to have hyperopic shifts in middle life. And even later, at older ages, myopic shifts are developed with nuclear cataract. The eye grows from 15 mm in premature newborns to approximately 24 mm in early adult years, but, in most cases, refractions are maintained stable in a clustered distribution. This growth in axial length would represent a refractive change of more than 40 diopters, which is compensated by changes in corneal and lens powers. The process which maintains the balance between the ocular components of refraction during growth is still under study. As the lens power cannot be measured in vivo, but can only be calculated based on the other ocular components, there have not been many studies of lens power in humans. Yet, recent studies have confirmed that the lens loses power during growth in children, and that hyperopic and myopic shifts in adulthood may be also produced by changes in the lens. These studies in children and adults give a picture of the changing power of the lens along lifespan. Other recent studies about the growth of the lens and the complexity of its internal structure give clues about how these changes in lens power are produced along life. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Single lens laser beam shaper

    Science.gov (United States)

    Liu, Chuyu [Newport News, VA; Zhang, Shukui [Yorktown, VA

    2011-10-04

    A single lens bullet-shaped laser beam shaper capable of redistributing an arbitrary beam profile into any desired output profile comprising a unitary lens comprising: a convex front input surface defining a focal point and a flat output portion at the focal point; and b) a cylindrical core portion having a flat input surface coincident with the flat output portion of the first input portion at the focal point and a convex rear output surface remote from the convex front input surface.

  9. TU-E-201-02: Eye Lens Dosimetry From CT Perfusion Studies

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, D. [Toshiba America Medical Systems (United States)

    2015-06-15

    . These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the

  10. TU-E-201-00: Eye Lens Dosimetry for Patients and Staff

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-06-15

    . These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the

  11. TU-E-201-02: Eye Lens Dosimetry From CT Perfusion Studies

    International Nuclear Information System (INIS)

    Zhang, D.

    2015-01-01

    . These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the

  12. TU-E-201-00: Eye Lens Dosimetry for Patients and Staff

    International Nuclear Information System (INIS)

    2015-01-01

    . These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the

  13. Resolving colocalization of bacteria and metal(loid)s on plant root surfaces by combining fluorescence in situ hybridization (FISH) with multiple-energy micro-focused X-ray fluorescence (ME μXRF).

    Science.gov (United States)

    Honeker, Linnea K; Root, Robert A; Chorover, Jon; Maier, Raina M

    2016-12-01

    Metal(loid)-contamination of the environment due to anthropogenic activities is a global problem. Understanding the fate of contaminants requires elucidation of biotic and abiotic factors that influence metal(loid) speciation from molecular to field scales. Improved methods are needed to assess micro-scale processes, such as those occurring at biogeochemical interfaces between plant tissues, microbial cells, and metal(loid)s. Here we present an advanced method that combines fluorescence in situ hybridization (FISH) with synchrotron-based multiple-energy micro-focused X-ray fluorescence microprobe imaging (ME μXRF) to examine colocalization of bacteria and metal(loid)s on root surfaces of plants used to phytostabilize metalliferous mine tailings. Bacteria were visualized on a small root section using SytoBC nucleic acid stain and FISH probes targeting the domain Bacteria and a specific group (Alphaproteobacteria, Gammaproteobacteria, or Actinobacteria). The same root region was then analyzed for elemental distribution and metal(loid) speciation of As and Fe using ME μXRF. The FISH and ME μXRF images were aligned using ImageJ software to correlate microbiological and geochemical results. Results from quantitative analysis of colocalization show a significantly higher fraction of As colocalized with Fe-oxide plaques on the root surfaces (fraction of overlap 0.49±0.19) than to bacteria (0.072±0.052) (proots, metal(loid)s and microbes, information that should lead to improved mechanistic models of metal(loid) speciation and fate. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. A course in lens design

    CERN Document Server

    Velzel, Chris

    2014-01-01

    A Course in Lens Design is an instruction in the design of image-forming optical systems. It teaches how a satisfactory design can be obtained in a straightforward way. Theory is limited to a minimum, and used to support the practical design work. The book introduces geometrical optics, optical instruments and aberrations. It gives a description of the process of lens design and of the strategies used in this process. Half of its content is devoted to the design of sixteen types of lenses, described in detail from beginning to end. This book is different from most other books on lens design because it stresses the importance of the initial phases of the design process: (paraxial) lay-out and (thin-lens) pre-design. The argument for this change of accent is that in these phases much information can be obtained about the properties of the lens to be designed. This information can be used in later phases of the design. This makes A Course in Lens Design a useful self-study book, and a suitable basis for an intro...

  15. Intraocular camera for retinal prostheses: Refractive and diffractive lens systems

    Science.gov (United States)

    Hauer, Michelle Christine

    The focus of this thesis is on the design and analysis of refractive, diffractive, and hybrid refractive/diffractive lens systems for a miniaturized camera that can be surgically implanted in the crystalline lens sac and is designed to work in conjunction with current and future generation retinal prostheses. The development of such an intraocular camera (IOC) would eliminate the need for an external head-mounted or eyeglass-mounted camera. Placing the camera inside the eye would allow subjects to use their natural eye movements for foveation (attention) instead of more cumbersome head tracking, would notably aid in personal navigation and mobility, and would also be significantly more psychologically appealing from the standpoint of personal appearances. The capability for accommodation with no moving parts or feedback control is incorporated by employing camera designs that exhibit nearly infinite depth of field. Such an ultracompact optical imaging system requires a unique combination of refractive and diffractive optical elements and relaxed system constraints derived from human psychophysics. This configuration necessitates an extremely compact, short focal-length lens system with an f-number close to unity. Initially, these constraints appear highly aggressive from an optical design perspective. However, after careful analysis of the unique imaging requirements of a camera intended to work in conjunction with the relatively low pixellation levels of a retinal microstimulator array, it becomes clear that such a design is not only feasible, but could possibly be implemented with a single lens system.

  16. Review of Micro Magnetic Generator

    Directory of Open Access Journals (Sweden)

    Lin DU

    2014-08-01

    Full Text Available This paper discusses the research progress of micro magnetic generator systems. Micro magnetic generator systems convert energy from the environment to electric energy with advantages as high reliability, high power density, long life time and can be applied to extreme environment. This paper summarizes methods for improving generator performance of micro magnetic generator, including rotational magnetic generator, vibrational magnetic generator and hybrid magnetic generator, analyzes and compares their design and performance, and concludes key technologies and ongoing challenges for further progress. The paper is instructive and meaningful to for research work of related field.

  17. Micro Vision

    OpenAIRE

    Ohba, Kohtaro; Ohara, Kenichi

    2007-01-01

    In the field of the micro vision, there are few researches compared with macro environment. However, applying to the study result for macro computer vision technique, you can measure and observe the micro environment. Moreover, based on the effects of micro environment, it is possible to discovery the new theories and new techniques.

  18. Wafer integrated micro-scale concentrating photovoltaics

    Science.gov (United States)

    Gu, Tian; Li, Duanhui; Li, Lan; Jared, Bradley; Keeler, Gordon; Miller, Bill; Sweatt, William; Paap, Scott; Saavedra, Michael; Das, Ujjwal; Hegedus, Steve; Tauke-Pedretti, Anna; Hu, Juejun

    2017-09-01

    Recent development of a novel micro-scale PV/CPV technology is presented. The Wafer Integrated Micro-scale PV approach (WPV) seamlessly integrates multijunction micro-cells with a multi-functional silicon platform that provides optical micro-concentration, hybrid photovoltaic, and mechanical micro-assembly. The wafer-embedded micro-concentrating elements is shown to considerably improve the concentration-acceptance-angle product, potentially leading to dramatically reduced module materials and fabrication costs, sufficient angular tolerance for low-cost trackers, and an ultra-compact optical architecture, which makes the WPV module compatible with commercial flat panel infrastructures. The PV/CPV hybrid architecture further allows the collection of both direct and diffuse sunlight, thus extending the geographic and market domains for cost-effective PV system deployment. The WPV approach can potentially benefits from both the high performance of multijunction cells and the low cost of flat plate Si PV systems.

  19. Submicron hollow spot generation by solid immersion lens and structured illumination

    NARCIS (Netherlands)

    Kim, M.S.; Assafrao, A.C.; Scharf, T.; Wachters, A.J.H.; Pereira, S.F.; Urbach, H.P.; Brun, M.; Olivier, S.; Nicoletti, S.; Herzig, H.P.

    2012-01-01

    We report on the experimental and numerical demonstration of immersed submicron-size hollow focused spots, generated by structuring the polarization state of an incident light beam impinging on a micro-size solid immersion lens (?-SIL) made of SiO2. Such structured focal spots are characterized by a

  20. Design of electrohydrodynamic lens for stabilizing of eletrohydrodynamic jet printing

    International Nuclear Information System (INIS)

    Park, Sung-Eun; Lee, Dae-Young; Kim, Sang-Yoon; Shin, Yoon-Soo; Hwang, Jungho; Yu, Tae-U

    2008-01-01

    The generation of micro patterns from conductive material suspensions is gaining significant interests for its usages in the fabrication of flexible display elements and flexible printed circuit boards. In this paper, we presented the results of line patterns of silver nanoparticles obtained by using various types of focusing lenses for electrohydrodynamic jet printing. The pattern widths were measured as 80∼100 μm when the electrohydrodynamic lens having a cone-type inner hole and a cone-type outer wall was used. Electric field strengths were calculated by a commercial solver packages for the four types of electrohydrodynamic lenses. A lens having a cone-type inner hole and a cone-type outer wall of thinner thickness was found to be the best design.

  1. Subtractive hybridization-mediated analysis of genes and in silico prediction of associated microRNAs under waterlogged conditions in sugarcane (Saccharum spp.

    Directory of Open Access Journals (Sweden)

    Mohammad Suhail Khan

    2014-01-01

    Full Text Available Sugarcane is an important tropical cash crop meeting 75% of world sugar demand and it is fast becoming an energy crop for the production of bio-fuel ethanol. A considerable area under sugarcane is prone to waterlogging which adversely affects both cane productivity and quality. In an effort to elucidate the genes underlying plant responses to waterlogging, a subtractive cDNA library was prepared from leaf tissue. cDNA clones were sequenced and annotated for their putative functions. Major groups of ESTs were related to stress (15%, catalytic activity (13%, cell growth (10% and transport related proteins (6%. A few stress-related genes were identified, including senescence-associated protein, dehydration-responsive family protein, and heat shock cognate 70 kDa protein. A bioinformatics search was carried out to discover novel microRNAs (miRNAs that can be regulated in sugarcane plants subjected to waterlogging stress. Taking advantage of the presence of miRNA precursors in the related sorghum genome, seven candidate mature miRNAs were identified in sugarcane. The application of subtraction technology allowed the identification of differentially expressed sequences and novel miRNAs in sugarcane under waterlogging stress. The comparative global transcript profiling in sugarcane plants undertaken in this study suggests that proteins associated with stress response, signal transduction, metabolic activity and ion transport play important role in conferring waterlogging tolerance in sugarcane.

  2. Subtractive hybridization-mediated analysis of genes and in silico prediction of associated microRNAs under waterlogged conditions in sugarcane (Saccharum spp.)

    KAUST Repository

    Khan, Mohammad Suhail

    2014-06-09

    Sugarcane is an important tropical cash crop meeting 75% of world sugar demand and it is fast becoming an energy crop for the production of bio-fuel ethanol. A considerable area under sugarcane is prone to waterlogging which adversely affects both cane productivity and quality. In an effort to elucidate the genes underlying plant responses to waterlogging, a subtractive cDNA library was prepared from leaf tissue. cDNA clones were sequenced and annotated for their putative functions. Major groups of ESTs were related to stress (15%), catalytic activity (13%), cell growth (10%) and transport related proteins (6%). A few stress-related genes were identified, including senescence-associated protein, dehydration-responsive family protein, and heat shock cognate 70. kDa protein. A bioinformatics search was carried out to discover novel microRNAs (miRNAs) that can be regulated in sugarcane plants subjected to waterlogging stress. Taking advantage of the presence of miRNA precursors in the related sorghum genome, seven candidate mature miRNAs were identified in sugarcane. The application of subtraction technology allowed the identification of differentially expressed sequences and novel miRNAs in sugarcane under waterlogging stress. The comparative global transcript profiling in sugarcane plants undertaken in this study suggests that proteins associated with stress response, signal transduction, metabolic activity and ion transport play important role in conferring waterlogging tolerance in sugarcane. © 2014 The Authors.

  3. A comparative study on low cycle fatigue behaviour of nano and micro Al2O3 reinforced AA2014 particulate hybrid composites

    Directory of Open Access Journals (Sweden)

    R. Senthilkumar

    2015-01-01

    Full Text Available Aluminium based metal matrix composites have drawn more attraction due to their improved properties in structural applications for the past two decades. The fatigue behaviour of composite materials needs to be studied for their structural applications. In this work, powder metallurgy based aluminium (AA2014 alloy reinforced with micro and nano-sized alumina particles were fabricated and consolidated with the hot extrusion process. The evaluation of mechanical properties in the extruded composite was carried out. This composite was subjected to low cycle fatigue test with a constant strain rate. Scanning Electron Microscope (SEM and Transmission Electron Microscope (TEM images were used to evaluate the fatigue behaviour of aluminium-nano composite samples. Enhanced mechanical properties were exhibited by the nano alumina reinforced aluminium composites, when compared to the micron sized alumina reinforced composites. The failure cycle is observed to be higher for the nano alumina reinforced composites when compared with micron sized alumina composites due to a lower order of induced plastic strain.

  4. In vitro characterization of a novel tissue engineered based hybridized nano and micro structured collagen implant and its in vivo role on tenoinduction, tenoconduction, tenogenesis and tenointegration.

    Science.gov (United States)

    Oryan, Ahmad; Moshiri, Ali; Meimandi-Parizi, Abdolhamid

    2014-03-01

    Surgical reconstruction of large tendon defects is technically demanding. Tissue engineering is a new option. We produced a novel tissue engineered, collagen based, bioimplant and in vitro characterizations of the implant were investigated. In addition, we investigated role of the collagen implant on the healing of a large tendon defect model in rabbits. A two cm length of the left rabbit's Achilles tendon was transected and discarded. The injured tendons of all the rabbits were repaired by Kessler pattern to create and maintain a 2 cm tendon gap. The collagen implant was inserted in the tendon defect of the treatment group (n = 30). The defect area was left intact in the control group (n = 30). The animals were euthanized at 60 days post injury (DPI) and the macro- micro- and nano- morphologies and the biomechanical characteristics of the tendon samples were studied. Differences of P implant properly incorporated with the healing tissue and was replaced by the new tendinous structure which was superior both ultra-structurally and physically than the loose areolar connective tissue regenerated in the control lesions. The results of this study may be valuable in the clinical practice.

  5. 110 GHz hybrid mode-locked fiber laser with enhanced extinction ratio based on nonlinear silicon-on-insulator micro-ring-resonator (SOI MRR)

    International Nuclear Information System (INIS)

    Liu, Yang; Hsu, Yung; Chow, Chi-Wai; Yang, Ling-Gang; Lai, Yin-Chieh; Yeh, Chien-Hung; Tsang, Hon-Ki

    2016-01-01

    We propose and experimentally demonstrate a new 110 GHz high-repetition-rate hybrid mode-locked fiber laser using a silicon-on-insulator microring-resonator (SOI MRR) acting as the optical nonlinear element and optical comb filter simultaneously. By incorporating a phase modulator (PM) that is electrically driven at a fraction of the harmonic frequency, an enhanced extinction ratio (ER) of the optical pulses can be produced. The ER of the optical pulse train increases from 3 dB to 10 dB. As the PM is only electrically driven by the signal at a fraction of the harmonic frequency, in this case 22 GHz (110 GHz/5 GHz), a low bandwidth PM and driving circuit can be used. The mode-locked pulse width and the 3 dB spectral bandwidth of the proposed mode-locked fiber laser are measured, showing that the optical pulses are nearly transform limited. Moreover, stability evaluation for an hour is performed, showing that the proposed laser can achieve stable mode-locking without the need for optical feedback or any other stabilization mechanism. (letter)

  6. Hybrid Iron Oxide-Graphene Oxide-Polysaccharides Microcapsule: A Micro-Matryoshka for On-demand Drug Release and Antitumor Therapy In Vivo

    KAUST Repository

    Deng, Lin

    2016-02-25

    Premature drug release is a common drawback in stimuli responsive drug delivery systems (DDS) especially if it depends on internal triggers, that are hard to control, or a single external stimulus, that can only have one function. Thus, many DDS systems were reported combining different triggers, however limited success has been established in fine-tuning the release process mainly due to the poor bioavailability and complexity of the reported designs. This paper reports the design of a hybrid microcapsule (h-MC) by a simple layer-by-layer technique comprising polysaccharides (Alg, Chi, HA), iron oxide, and graphene oxide. Electrostatic assembly of the oppositely charged polysaccharides and graphene sheets provided a robust structure to load drugs through pH control. The polysaccharides component ensured high biocompatibility, bioavailability, and tumor cells targeting. Magnetic field and near infrared laser triggerable Fe3O4@GO component provided dual high energy and high penetration hyperthermia therapy. On-demand drug release from h-MC can be achieved by synchronizing these external triggers, making it highly controllable. The synergistic effect of hyperthermia and chemotherapy was successfully confirmed in vitro and in vivo.

  7. Contact Lens Visual Rehabilitation in Keratoconus and Corneal Keratoplasty

    Directory of Open Access Journals (Sweden)

    Yelda Ozkurt

    2012-01-01

    Full Text Available Keratoconus is the most common corneal distrophy. It’s a noninflammatory progressive thinning process that leads to conical ectasia of the cornea, causing high myopia and astigmatism. Many treatment choices include spectacle correction and contact lens wear, collagen cross linking, intracorneal ring segments implantation and finally keratoplasty. Contact lenses are commonly used to reduce astigmatism and increase vision. There are various types of lenses are available. We reviewed soft contact lenses, rigid gas permeable contact lenses, piggyback contact lenses, hybrid contact lenses and scleral-semiscleral contact lenses in keratoconus management. The surgical option is keratoplasty, but even after sutur removal, high astigmatism may stil exists. Therefore, contact lens is an adequate treatment option to correct astigmatism after keratoplasty.

  8. Comprehending the Macro Through the Lens of the Micro

    Directory of Open Access Journals (Sweden)

    Lisa Zimmerman

    2016-02-01

    Full Text Available The South African Grade 4 learners had the lowest achievement mean of all participating education systems for the Progress in International Reading Literacy Study (PIRLS 2006. Further investigation was required to explore the potential reasons for the low performance. Although traditionally, secondary analyses of the data for international comparative studies of learner achievement have involved quantitative procedures, the mixed methods research design used for this study with emphasis placed on the qualitative phase was a unique departure from this methodological status quo. The aim was to explore schooling conditions and teaching practices for Grade 4 learners’ reading literacy development across the range of South African education contexts. In the first phase of the research, teacher and school survey data linked to a nationally representative learner sample (n = 14,299 for the PIRLS 2006 were used for description of Grade 4 teachers’ instruction practices and schooling conditions. This description took place on the basis of the reclassification of the teacher and school survey data according to class language profiles and average class performance as aligned to each of the achievement benchmarks of the PIRLS 2006 and further benchmarks created to describe the performance levels of the majority of South African learners. Thereafter, in the second phase, seven qualitative school and teacher case studies from each reclassification subsample were purposively selected to add illuminatory depth to the study. The sampling strategy allowed for scrutiny of cases with high PIRLS achievement profiles against cases with poor achievement profiles, and the comparisons afforded a far greater understanding of the problem. This article reflects on the methodological rationales, processes, and outcomes associated with this methodological choice.

  9. Tinting of intraocular lens implants

    Energy Technology Data Exchange (ETDEWEB)

    Zigman, S.

    1982-06-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users.

  10. Tinting of intraocular lens implants

    International Nuclear Information System (INIS)

    Zigman, S.

    1982-01-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users

  11. Automated Fresnel lens tester system

    Energy Technology Data Exchange (ETDEWEB)

    Phipps, G.S.

    1981-07-01

    An automated data collection system controlled by a desktop computer has been developed for testing Fresnel concentrators (lenses) intended for solar energy applications. The system maps the two-dimensional irradiance pattern (image) formed in a plane parallel to the lens, whereas the lens and detector assembly track the sun. A point detector silicon diode (0.5-mm-dia active area) measures the irradiance at each point of an operator-defined rectilinear grid of data positions. Comparison with a second detector measuring solar insolation levels results in solar concentration ratios over the image plane. Summation of image plane energies allows calculation of lens efficiencies for various solar cell sizes. Various graphical plots of concentration ratio data help to visualize energy distribution patterns.

  12. Lens system for SIMS analysis

    International Nuclear Information System (INIS)

    Martinez, G.; Sancho, M.; Garcia-Galan, J.C.

    1987-01-01

    A powerful version of the charge-density method is applied to the study of a combined objective and emission lens, suitable for highly localized analysis of a flat sample surface. This lens can extract secondary ions of equal or opposite polarity to that of the primary particles. A computer simulation of the ion trajectories for both modes is made. The behaviour for different values of the geometric parameters and polarizations is analyzed and useful data for design such as primary beam demagnification and secondary image position are given. (author) 4 refs

  13. Refractive lens exchange with a multifocal diffractive aspheric intraocular lens

    Directory of Open Access Journals (Sweden)

    Teresa Ferrer-Blasco

    2012-06-01

    Full Text Available PURPOSE: To evaluate the safety, efficacy and predictability after refractive lens exchange with multifocal diffractive aspheric intraocular lens implantation. METHODS: Sixty eyes of 30 patients underwent bilateral implantation with AcrySof® ReSTOR® SN6AD3 intraocular lens with +4.00 D near addition. Patients were divided into myopic and hyperopic groups. Monocular best corrected visual acuity at distance and near and monocular uncorrected visual acuity at distance and near were measured before and 6 months postoperatively. RESULTS: After surgery, uncorrected visual acuity was 0.08 ± 0.15 and 0.11 ± 0.14 logMAR for the myopic and hyperopic groups, respectively (50% and 46.67% of patients had an uncorrected visual acuity of 20/20 or better in the myopic and hyperopic groups, respectively. The safety and efficacy indexes were 1.05 and 0.88 for the myopic and 1.01 and 0.86 for the hyperopic groups at distance vision. Within the myopic group, 20 eyes remained unchanged after the surgery, and 3 gained >2 lines of best corrected visual acuity. For the hyperopic group, 2 eyes lost 2 lines of best corrected visual acuity, 21 did not change, and 3 eyes gained 2 lines. At near vision, the safety and efficacy indexes were 1.23 and 1.17 for the myopic and 1.16 and 1.13 for the hyperopic groups. Best corrected near visual acuity improved after surgery in both groups (from 0.10 logMAR to 0.01 logMAR in the myopic group, and from 0.10 logMAR to 0.04 logMAR in the hyperopic group. CONCLUSIONS: The ReSTOR® SN6AD3 intraocular lens in refractive lens exchange demonstrated good safety, efficacy, and predictability in correcting high ametropia and presbyopia.

  14. Stretchable Binary Fresnel Lens for Focus Tuning

    NARCIS (Netherlands)

    Li, X.; Wei, L.; Poelma, R.H.; Vollebregt, S.; Wei, J.; Urbach, Paul; Sarro, P.M.; Zhang, G.Q.

    2016-01-01

    This paper presents a tuneable binary amplitude Fresnel lens produced by wafer-level microfabrication. The Fresnel lens is fabricated by encapsulating lithographically defined vertically aligned carbon nanotube (CNT) bundles inside a polydimethyl-siloxane (PDMS) layer. The composite lens material

  15. 21 CFR 886.1400 - Maddox lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Maddox lens. 886.1400 Section 886.1400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1400 Maddox lens. (a) Identification. A Maddox lens is a device...

  16. Crystalline lens power and refractive error.

    Science.gov (United States)

    Iribarren, Rafael; Morgan, Ian G; Nangia, Vinay; Jonas, Jost B

    2012-02-01

    To study the relationships between the refractive power of the crystalline lens, overall refractive error of the eye, and degree of nuclear cataract. All phakic participants of the population-based Central India Eye and Medical Study with an age of 50+ years were included. Calculation of the refractive lens power was based on distance noncycloplegic refractive error, corneal refractive power, anterior chamber depth, lens thickness, and axial length according to Bennett's formula. The study included 1885 subjects. Mean refractive lens power was 25.5 ± 3.0 D (range, 13.9-36.6). After adjustment for age and sex, the standardized correlation coefficients (β) of the association with the ocular refractive error were highest for crystalline lens power (β = -0.41; P lens opacity grade (β = -0.42; P lens power (β = -0.95), lower corneal refractive power (β = -0.76), higher lens thickness (β = 0.30), deeper anterior chamber (β = 0.28), and less marked nuclear lens opacity (β = -0.05). Lens thickness was significantly lower in eyes with greater nuclear opacity. Variations in refractive error in adults aged 50+ years were mostly influenced by variations in axial length and in crystalline lens refractive power, followed by variations in corneal refractive power, and, to a minor degree, by variations in lens thickness and anterior chamber depth.

  17. 21 CFR 886.3600 - Intraocular lens.

    Science.gov (United States)

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3600 Intraocular lens. (a) Identification. An intraocular lens is a device made of materials such as glass or plastic intended to be implanted to replace the natural lens of an eye. (b) Classification. Class III. (c) Date PMA or notice of completion of a...

  18. Development of a dry actuation conducting polymer actuator for micro-optical zoom lenses

    Science.gov (United States)

    Kim, Baek-Chul; Kim, Hyunseok; Nguyen, H. C.; Cho, M. S.; Lee, Y.; Nam, Jae-Do; Choi, Hyouk Ryeol; Koo, J. C.; Jeong, H.-S.

    2008-03-01

    The objective of the present work is to demonstrate the efficiency and feasibility of NBR (Nitrile Butadiene Rubber) based conducting polymer actuator that is fabricated into a micro zoon lens driver. Unlike the traditional conducting polymer that normally operates in a liquid, the proposed actuator successfully provides fairly effective driving performance for the zoom lens system in a dry environment. And this paper is including the experiment results for an efficiency improvement. The result suggested by an experiment was efficient in micro optical zoom lens system. In addition, the developed design method of actuator was given consideration to design the system.

  19. The Ultrawideband Leaky Lens Antenna

    NARCIS (Netherlands)

    Bruni, S.; Neto, A.; Marliani, F.

    2007-01-01

    A novel directive and nondispersive antenna is presented: the ultrawideband (UWB) leaky lens. It is based on the broad band Cherenkov radiation occurring at a slot printed between different infinite homogeneous dielectrics. The first part of the paper presents the antenna concept and the UWB design.

  20. ECTOPIC LENS EXTRACTION IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Vladimir Pfeifer

    2002-12-01

    Full Text Available Background. Ectopia lentis continues to be a therapeutic challenge for ophthalmologists. It can occur as an isolated condition, after ocular trauma, in association with other ocular disorders, as part of a systemic mesodermal disease or a complication of general metabolic disorders. Minimal subluxation of the lens may cause no visual symptoms, but in more advanced cases serious optical disturbances arise. The most important is amblyopia. Surgical treatment options include iris manipulation, lens discission, aspiration, intracapsular or extracapsular extraction, and pars plana lensectomy. The choice of surgical technique remains controversial, in part because of the historically poor visual results and high rate of perioperative complications, including vitreous loss and retinal detachment.Methods. We describe a surgical technique based on the use of the Cionni endocapsular tension ring, dry irrigation aspiration of lens material, centration of the capsular bag and foldable intraocular lens implantation into the bag. With mentioned surgical technique 8 patients were operated; 4 boys and 4 girls, together 11 eyes.Results. The final BCVA after follow up period improved in 9 eyes and it remained the same as before operation in one eye. Statistical comparison of preoperative and postoperative visual acuities showed significant improvement. On the other hand there was no correlation between preoperative and postoperative visual acuity.Conclusions. This surgical procedure is an alternative approach in solving this challenging cases of ectopia lentis with good postoperative visual rehabilitation.

  1. Lens stem cells may reside outside the lens capsule: an hypothesis

    Directory of Open Access Journals (Sweden)

    Meyer Rita A

    2007-06-01

    Full Text Available Abstract In this paper, we consider the ocular lens in the context of contemporary developments in biological ideas. We attempt to reconcile lens biology with stem cell concepts and a dearth of lens tumors. Historically, the lens has been viewed as a closed system, in which cells at the periphery of the lens epithelium differentiate into fiber cells. Theoretical considerations led us to question whether the intracapsular lens is indeed self-contained. Since stem cells generate tumors and the lens does not naturally develop tumors, we reasoned that lens stem cells may not be present within the capsule. We hypothesize that lens stem cells reside outside the lens capsule, in the nearby ciliary body. Our ideas challenge the existing lens biology paradigm. We begin our discussion with lens background information, in order to describe our lens stem cell hypothesis in the context of published data. Then we present the ciliary body as a possible source for lens stem cells, and conclude by comparing the ocular lens with the corneal epithelium.

  2. Regulation of potassium transport in human lens epithelial cells.

    Science.gov (United States)

    Lauf, Peter K; Warwar, Ronald; Brown, Thomas L; Adragna, Norma C

    2006-01-01

    The major K influx pathways and their response to thiol modification by N-ethylmaleimide (NEM) and protein kinase and phosphatase inhibitors were characterized in human lens epithelial B3 (HLE-B3) cells with Rb as K congener. Ouabain (0.1 mM) and bumetanide (5 microM) discriminated between the Na/K pump ( approximately 35% of total Rb influx) and Na-K-2Cl cotransport (NKCC) ( approximately 50%). Cl-replacement with nitrate or sulfamate revealed 100 microM, activated the Na/K pump and abolished NKCC but did not affect KCC. The data suggest at least partial inverse regulation of KCC and NKCC in HLE-B3 cells by signaling cascades involving serine, threonine and tyrosine phosphorylation/dephosphorylation equilibria.

  3. Modern lens antennas for communications engineering

    CERN Document Server

    Thornton, John

    2012-01-01

    The aim of this book is to present the modern design principles and analysis of lens antennas. It gives graduates and RF/Microwave professionals the design insights in order to make full use of lens antennas.  Why do we want to write a book in lens antennas? Because this topic has not been thoroughly publicized, its importance is underestimated. As antennas play a key role in communication systems, recent development in wireless communications would indeed benefit from the characteristics of lens antennas: low profile, and low cost etc.  The major advantages of lens antennas are na

  4. Lens-free imaging of magnetic particles in DNA assays.

    Science.gov (United States)

    Colle, Frederik; Vercruysse, Dries; Peeters, Sara; Liu, Chengxun; Stakenborg, Tim; Lagae, Liesbet; Del-Favero, Jurgen

    2013-11-07

    We present a novel opto-magnetic system for the fast and sensitive detection of nucleic acids. The system is based on a lens-free imaging approach resulting in a compact and cheap optical readout of surface hybridized DNA fragments. In our system magnetic particles are attracted towards the detection surface thereby completing the labeling step in less than 1 min. An optimized surface functionalization combined with magnetic manipulation was used to remove all nonspecifically bound magnetic particles from the detection surface. A lens-free image of the specifically bound magnetic particles on the detection surface was recorded by a CMOS imager. This recorded interference pattern was reconstructed in software, to represent the particle image at the focal distance, using little computational power. As a result we were able to detect DNA concentrations down to 10 pM with single particle sensitivity. The possibility of integrated sample preparation by manipulation of magnetic particles, combined with the cheap and highly compact lens-free detection makes our system an ideal candidate for point-of-care diagnostic applications.

  5. Contact lens surface by electron beam

    International Nuclear Information System (INIS)

    Shin, Jung Hyuck; Lee, Suk Ju; Hwang, Kwang Ha; Jeon Jin

    2011-01-01

    Contact lens materials needs good biocompatibility, high refractive index, high optical transparency, high water content etc. Surface treat method by using plasma and radiation can modify the physical and/or chemical properties of the contact lens surface. Radiation technology such as electron beam irradiation can apply to polymerization reaction and enhance the functionality of the polymer.The purpose of this study is to modify of contact lens surface by using Eb irradiation technology. Electron beam was irradiated to the contact lens surface which was synthesized thermal polymerization method and commercial contact lens to modify physical and chemical properties. Ft-IR, XP, UV-vis spectrophotometer, water content, oxygen trans-metastability were used to characterize the surface state, physicochemical, and optical property of the contact lens treated with Eb. The water content and oxygen transmissibility of the contact lens treated with Eb were increased due to increase in the hydrophilic group such as O-C=O and OH group on the contact lens surface which could be produced by possible reaction between carbon and oxygen during the Eb irradiation. All of the lenses showed the high optical transmittance above 90%. In this case of B/Es, TES, Ti contact lens, the optical transmittance decreased about 5% with increasing Eb dose in the wavelength of UV-B region. The contact lens modified by Eb irradiation could improve the physical properties of the contact lens such as water content and oxygen transmissibility

  6. Lens decenter and tilt measurement by interferogram

    Science.gov (United States)

    Hung, Min-Wei; Wu, Wen-Hong; Huang, Kuo-Cheng

    2009-11-01

    For the recent years, the vigorous development of the electro-optic industry, particularly the digital camera and the cellular phone camera, has placed a larger and larger demand for the optical devices. Among the optical lens, the aspherical optical lens plays the key component because the aspherical lens may provide better imaging quality then the spherical lens does. For the manufacturing reason, the aspherical lens is prone to a decenter or tilt issue with respect to the optical axes of its two surfaces. To measure decenter and tile error specifically would help to obviate the deficient lens, but most of the present measuring method can't provide this function. This paper proposed a new method to specifically measure the decenter and tile of lens by observing the interferogram of each surface. And the corresponding measuring instrument, which contains interferometer and motion stages, was introduced as well.

  7. Plasma Lens for Muon and Neutrino Beams

    Science.gov (United States)

    Kahn, Stephen; Korenev, Sergey; Bishai, Mary; Diwan, Milind; Gallardo, Juan; Hershcovitch, Ady; Johnson, Brant

    2008-04-01

    The plasma lens is examined as an alternate to focusing horns and solenoids for use in a neutrino or muon beam facility. The plasma lens concept is based on a combined high-current lens/target configuration. The current is fed at electrodes located upstream and downstream from the target where pion capturing is needed. The current flows primarily in the plasma, which has a lower resistivity than the target. A second plasma lens section, with an additional current feed, follows the target to provide shaping of the plasma stability. The geometry of the plasma is shaped to provide optimal pion capture. Simulations of this plasma lens system have shown a 25% higher neutrino production than the horn system. A plasma lens has additional advantage: larger axial current than horns, minimal neutrino contamination during antineutrino running, and negligible pion absorption or scattering. Results from particle simulations using a plasma lens will be presented.

  8. Metasurface Enabled Wide-Angle Fourier Lens.

    Science.gov (United States)

    Liu, Wenwei; Li, Zhancheng; Cheng, Hua; Tang, Chengchun; Li, Junjie; Zhang, Shuang; Chen, Shuqi; Tian, Jianguo

    2018-06-01

    Fourier optics, the principle of using Fourier transformation to understand the functionalities of optical elements, lies at the heart of modern optics, and it has been widely applied to optical information processing, imaging, holography, etc. While a simple thin lens is capable of resolving Fourier components of an arbitrary optical wavefront, its operation is limited to near normal light incidence, i.e., the paraxial approximation, which puts a severe constraint on the resolvable Fourier domain. As a result, high-order Fourier components are lost, resulting in extinction of high-resolution information of an image. Other high numerical aperture Fourier lenses usually suffer from the bulky size and costly designs. Here, a dielectric metasurface consisting of high-aspect-ratio silicon waveguide array is demonstrated experimentally, which is capable of performing 1D Fourier transform for a large incident angle range and a broad operating bandwidth. Thus, the device significantly expands the operational Fourier space, benefitting from the large numerical aperture and negligible angular dispersion at large incident angles. The Fourier metasurface will not only facilitate efficient manipulation of spatial spectrum of free-space optical wavefront, but also be readily integrated into micro-optical platforms due to its compact size. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Simulation of light propagation in the thin-film waveguide lens

    Science.gov (United States)

    Malykh, M. D.; Divakov, D. V.; Sevastianov, L. A.; Sevastianov, A. L.

    2018-04-01

    In this paper we investigate the solution of the problem of modeling the propagation of electromagnetic radiation in three-dimensional integrated optical structures, such as waveguide lenses. When propagating through three-dimensional waveguide structures the waveguide modes can be hybridized, so the mathematical model of their propagation must take into account the connection of TE- and TM-mode components. Therefore, an adequate consideration of hybridization of the waveguide modes is possible only in vector formulation of the problem. An example of three-dimensional structure that hybridizes waveguide modes is the Luneburg waveguide lens, which also has focusing properties. If the waveguide lens has a radius of the order of several tens of wavelengths, its variable thickness at distances of the order of several wavelengths is almost constant. Assuming in this case that the electromagnetic field also varies slowly in the direction perpendicular to the direction of propagation, one can introduce a small parameter characterizing this slow varying and decompose the solution in powers of the small parameter. In this approach, in the zeroth approximation, scalar diffraction problems are obtained, the solution of which is less resource-consuming than the solution of vector problems. The calculated first-order corrections of smallness describe the connection of TE- and TM-modes, so the solutions obtained are weakly-hybridized modes. The formulation of problems and methods for their numerical solution in this paper are based on the authors' research on waveguide diffraction on a lens in a scalar formulation.

  10. Lens Coupled Quantum Cascade Laser

    Science.gov (United States)

    Hu, Qing (Inventor); Lee, Alan Wei Min (Inventor)

    2013-01-01

    Terahertz quantum cascade (QC) devices are disclosed that can operate, e.g., in a range of about 1 THz to about 10 THz. In some embodiments, QC lasers are disclosed in which an optical element (e.g., a lens) is coupled to an output facet of the laser's active region to enhance coupling of the lasing radiation from the active region to an external environment. In other embodiments, terahertz amplifier and tunable terahertz QC lasers are disclosed.

  11. Looking beyond the perfect lens

    International Nuclear Information System (INIS)

    Wee, W H; Pendry, J B

    2010-01-01

    The holy grail of imaging is the ability to see through anything. From the conservation of energy, we can easily see that to see through a lossy material would require lenses with gain. The aim of this paper therefore is to propose a simple scheme by which we can construct a general perfect lens, with gain-one that can restore both the phases and amplitudes of near and far fields.

  12. CONTACT LENS RELATED CORNEAL ULCER

    Directory of Open Access Journals (Sweden)

    AGARWAL P

    2010-01-01

    Full Text Available A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are:overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. The presenting symptoms of contact lens related corneal ulcers include eye discomfort, foreign body sensation and lacrimation. More serious symptoms are redness (especially circum-corneal injection, severe pain, photophobia, eye discharge and blurring of vision. The diagnosis is established by a thorough slit lamp microscopic examination with fluorescein staining and corneal scraping for Gram stain and culture of the infective organism. Delay in diagnosing and treatment can cause permanent blindness, therefore an early referral to ophthalmologist and commencing of antimicrobial therapy can prevent visual loss.

  13. Glycation precedes lens crystallin aggregation

    International Nuclear Information System (INIS)

    Swamy, M.S.; Perry, R.E.; Abraham, E.C.

    1987-01-01

    Non-enzymatic glycosylation (glycation) seems to have the potential to alter the structure of crystallins and make them susceptible to thiol oxidation leading to disulfide-linked high molecular weight (HMW) aggregate formation. They used streptozotocin diabetic rats during precataract and cataract stages and long-term cell-free glycation of bovine lens crystallins to study the relationship between glycation and lens crystallin aggregation. HMW aggregates and other protein components of the water-soluble (WS) and urea-soluble (US) fractions were separated by molecular sieve high performance liquid chromatography. Glycation was estimated by both [ 3 H]NaBH 4 reduction and phenylboronate agarose affinity chromatography. Levels of total glycated protein (GP) in the US fractions were about 2-fold higher than in the WS fractions and there was a linear increase in GP in both WS and US fractions. This increase was parallelled by a corresponding increase in HMW aggregates. Total GP extracted by the affinity method from the US fraction showed a predominance of HMW aggregates and vice versa. Cell-free glycation studies with bovine crystallins confirmed the results of the animals studies. Increasing glycation caused a corresponding increase in protein insolubilization and the insoluble fraction thus formed also contained more glycated protein. It appears that lens protein glycation, HMW aggregate formation, and protein insolubilization are interrelated

  14. The Effect of the Crystalline Lens on Central Vault After Implantable Collamer Lens Implantation.

    Science.gov (United States)

    Qi, Meng-Ying; Chen, Qian; Zeng, Qing-Yan

    2017-08-01

    To identify associations between crystalline lens-related factors and central vault after Implantable Collamer Lens (ICL) (Staar Surgical, Monrovia, CA) implantation. This retrospective clinical study included 320 eyes from 186 patients who underwent ICL implantation surgery. At 1 year after surgery, the central vault was measured using anterior segment optical coherence tomography. Preoperative anterior chamber depth, lens thickness, lens position (lens position = anterior chamber depth + 1/2 lens thickness), and vault were analyzed to investigate the effects of lens-related factors on postoperative vault. The mean vault was 513 ± 215 µm at 1 year after surgery. Vault was positively correlated with preoperative anterior chamber depth (r = 0.495, P lens position (r = 0.371, P lens thickness (r = -0.262, P lens position than eyes in the other two vault groups (which had vaults ≥ 250 µm) (P lens position less than 5.1 mm had greatly reduced vaults (P lens could have an important influence on postoperative vault. Eyes with a shallower anterior chamber and a forward lens position will have lower vaults. [J Refract Surg. 2017;33(8):519-523.]. Copyright 2017, SLACK Incorporated.

  15. The effect of melatonin on eye lens of rats exposed to ultraviolet radiation.

    Science.gov (United States)

    Anwar, M M; Moustafa, M A

    2001-05-01

    We investigated the influence of exogenously administered melatonin on adult rats eye lenses exposed to ultraviolet radiation (UV) A and B ranging from 356-254 nm irradiation at 8 microW/cm(2). Rats exposed to this range of UV for 15 min for one week showed a significant (PUV-radiation significantly (PUV irradiation, may be the main cause of lens opacification. Melatonin injection with radiation significantly reduced (Pradiation, SOD and GSH-Px enzyme activities increased significantly (PUV radiation was as effective as melatonin treatment concurrent with UV irradiation. We conclude that melatonin may protect the eye lens from the damaging effects of UV exposure, and its actions protect lens from oxidative stress, elevating Ca(2+) levels, which are considered as an important causes of cataractogenesis.

  16. Application of the micro-array comparative genomic hybridization technology in preimplantation genetic diagnosis%Array-CGH技术在胚胎植入前遗传学诊断中的应用进展

    Institute of Scientific and Technical Information of China (English)

    韩丹; 陈大蔚; 曹云霞; 周平

    2015-01-01

    As a new kind high-throughput genomics technology, micro array-based comparative genomic hybridization (aCGH) has brought the huge change for molecular biology and medical research. Because of the detection range covers the whole genome, high efficiency, easy operation etc, aCGH has been widely used in many areas of human genetic disease diagnosis, tumor genomics, systems biology and prenatal diagnosis. Human preimplantation genetic diagnosis (PGD) is an important part of assisted reproductive technology, with the development of molecular genetics technology, its application range is continuously widening. Based on aCGH technology in PGD for embryonic whole genome screening for aneuploidy and structural abnormalities, human PGD/human preimplantation genetic screening (PGS) implantation rate and clinical pregnancy rate have improved significantly. In this article, we discussed the advantages, disadvantages and prospects of aCGH in prenatal diagnosis.%微阵列比较基因组杂交(aCGH)作为一种新兴的高通量检测技术,给分子生物学及医学研究带来了巨大变化,因其检测范围覆盖全基因组、高效率、操作简便等特点,在人类遗传疾病诊断,肿瘤基因组学,系统生物学研究及产前诊断中已有了广泛应用。植入前遗传学诊断(PGD)是辅助生殖技术的重要组成部分,随着分子遗传学技术的发展,其应用范围也不断拓宽。基于aCGH技术在PGD中对胚胎全染色体组非整倍体及结构异常的筛查,PGD/植入前遗传学筛查(PGS)胚胎植入率和临床妊娠率均有显著提高,本文就aCGH技术在胚胎植入前遗传学诊断中的应用进行综述。

  17. Report on achievements in fiscal 1998. Development of technologies to put photovoltaic power generation systems into practical use - international joint demonstration and development of photovoltaic power generation systems (Demonstrative research on photovoltaic power and micro hydraulic power hybrid system); 1998 nendo taiyoko hatsuden system jitsuyoka gijutsu kaihatsu seika hokokusho. Taiyoko hatsuden system kokusai kyodo jissho kaihatsu (taiyoko micro suiryoku hybrid system jissho kenkyu)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    A photovoltaic (PV) power plant is compounded with a micro hydroelectric (MH) power plant in Vietnam, who has a dry season and a rainy season, to structure a stabilized power supply system to compensate drawbacks of the respective systems. Full load operation is being performed to advance the development of technologies to optimize and improve the performance and reliability of the system. The works include (1) site surveys, and decision on a location to execute the demonstration research, (2) design of the system, and design and fabrication of devices, and (3) the building construction thereof. In Item (1), the location was decided at Trang Village, Vietnam from such installing conditions as annual average insolation, water channels for wheel turbines, energy complementing relations, load demand amount, and difficulty of installation. In Item (2), the system consists of PV:100 kW/MH:25 kW/control system, wherein the MH is an inductive generator. The Main devices include generators, batteries, inverters, system control panels, and a meteorological data recording device. In Item (3) land survey and development were completed. (NEDO)

  18. Primary intraocular lens implantation for penetrating lens trauma in Africa.

    Science.gov (United States)

    Bowman, R J; Yorston, D; Wood, M; Gilbert, C; Foster, A

    1998-09-01

    This study aimed to audit the surgical strategy of primary posterior chamber intraocular lens implantation for cases of recent penetrating trauma involving the lens in an African population. Retrospective, noncomparative case series. Seventy-two cases are reported, including all patients who underwent primary intraocular lens implantation for traumatic cataract extraction performed within 1 month of injury between 1988 and 1996. Demographic characteristics and follow-up attendance rates are analyzed. Surgical technique and the occurrence of intraoperative and postoperative complications are reported. Visual outcomes are reported with detailed analysis for cases of poor visual outcome. Mean age was 14.3 years (standard deviation = 11.1), 57 (79%) were male and 15 (21%) were female (chi-square = 23.66, P capsule had been breached by the trauma in 27 (38%) cases, and 15 of these required anterior vitrectomy. Capsular fixation of the implant was achieved in 49% of patients, the remainder having sulcus fixation. Intraoperative rupture of the posterior capsule occurred in four cases. The only common postoperative complication was acute fibrinous anterior uveitis, which occurred in 29 (40%) patients, and 32% of patients followed up for at least 6 months required secondary posterior capsulotomy. This was more common in younger patients (chi-square = 4.2, P < 0.05). Corrected postoperative visual acuities were available for 51 patients, of which 71% achieved 20/60 or better visual acuity. Patients 6 years of age or younger were less likely to achieve 20/60 (chi-square = 6.61, P = 0.01). This surgical strategy has proved successful, producing good visual results and causing no sight-threatening complications. Primary posterior capsulotomy may be appropriate for younger patients.

  19. DISSECTING THE GRAVITATIONAL LENS B1608+656. I. LENS POTENTIAL RECONSTRUCTION

    NARCIS (Netherlands)

    Suyu, S. H.; Marshall, P. J.; Blandford, R. D.; Fassnacht, C. D.; Koopmans, L. V. E.; McKean, J. P.; Treu, T.

    2009-01-01

    Strong gravitational lensing is a powerful technique for probing galaxy mass distributions and for measuring cosmological parameters. Lens systems with extended source-intensity distributions are particularly useful for this purpose since they provide additional constraints on the lens potential (

  20. Polymer dispensing and embossing technology for the lens type LED packaging

    Science.gov (United States)

    Chien, Chien-Lin Chang; Huang, Yu-Che; Hu, Syue-Fong; Chang, Chung-Min; Yip, Ming-Chuen; Fang, Weileun

    2013-06-01

    This study presents a ring-type micro-structure design on the substrate and its corresponding micro fabrication processes for a lens-type light-emitting diode (LED) package. The dome-type or crater-type silicone lenses are achieved by a dispensing and embossing process rather than a molding process. Silicone with a high viscosity and thixotropy index is used as the encapsulant material. The ring-type micro structure is adopted to confine the dispensed silicone encapsulant so as to form the packaged lens. With the architecture and process described, this LED package technology herein has three merits: (1) the flexibility of lens-type LED package designs is enhanced; (2) a dome-type package design is used to enhance the intensity; (3) a crater-type package design is used to enhance the view angle. Measurement results show the ratio between the lens height and lens radius can vary from 0.4 to 1 by changing the volume of dispensed silicone. The view angles of dome-type and crater-type packages can reach 155° ± 5° and 175° ± 5°, respectively. As compared with the commercial plastic leaded chip carrier-type package, the luminous flux of a monochromatic blue light LED is improved by 15% by the dome-type package (improved by 7% by the crater-type package) and the luminous flux of a white light LED is improved by 25% by the dome-type package (improved by 13% by the crater-type package). The luminous flux of monochromatic blue light LED and white light LED are respectively improved by 8% and 12% by the dome-type package as compare with the crater-type package.

  1. Role of Aquaporin 0 in lens biomechanics

    International Nuclear Information System (INIS)

    Sindhu Kumari, S.; Gupta, Neha; Shiels, Alan; FitzGerald, Paul G.; Menon, Anil G.; Mathias, Richard T.; Varadaraj, Kulandaiappan

    2015-01-01

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5 −/− ), AQP0 KO (heterozygous KO: AQP0 +/− ; homozygous KO: AQP0 −/− ; all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0 +/− lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and together they help to

  2. Algorithm design of liquid lens inspection system

    Science.gov (United States)

    Hsieh, Lu-Lin; Wang, Chun-Chieh

    2008-08-01

    In mobile lens domain, the glass lens is often to be applied in high-resolution requirement situation; but the glass zoom lens needs to be collocated with movable machinery and voice-coil motor, which usually arises some space limits in minimum design. In high level molding component technology development, the appearance of liquid lens has become the focus of mobile phone and digital camera companies. The liquid lens sets with solid optical lens and driving circuit has replaced the original components. As a result, the volume requirement is decreased to merely 50% of the original design. Besides, with the high focus adjusting speed, low energy requirement, high durability, and low-cost manufacturing process, the liquid lens shows advantages in the competitive market. In the past, authors only need to inspect the scrape defect made by external force for the glass lens. As to the liquid lens, authors need to inspect the state of four different structural layers due to the different design and structure. In this paper, authors apply machine vision and digital image processing technology to administer inspections in the particular layer according to the needs of users. According to our experiment results, the algorithm proposed can automatically delete non-focus background, extract the region of interest, find out and analyze the defects efficiently in the particular layer. In the future, authors will combine the algorithm of the system with automatic-focus technology to implement the inside inspection based on the product inspective demands.

  3. Freeform lens design for LED collimating illumination.

    Science.gov (United States)

    Chen, Jin-Jia; Wang, Te-Yuan; Huang, Kuang-Lung; Liu, Te-Shu; Tsai, Ming-Da; Lin, Chin-Tang

    2012-05-07

    We present a simple freeform lens design method for an application to LED collimating illumination. The method is derived from a basic geometric-optics analysis and construction approach. By using this method, a highly collimating lens with LED chip size of 1.0 mm × 1.0 mm and optical simulation efficiency of 86.5% under a view angle of ± 5 deg is constructed. To verify the practical performance of the lens, a prototype of the collimator lens is also made, and an optical efficiency of 90.3% with a beam angle of 4.75 deg is measured.

  4. Micro Manufacturing

    DEFF Research Database (Denmark)

    Hansen, Hans Nørgaard

    2003-01-01

    Manufacturing deals with systems that include products, processes, materials and production systems. These systems have functional requirements, constraints, design parameters and process variables. They must be decomposed in a systematic manner to achieve the best possible system performance....... If a micro manufacturing system isn’t designed rationally and correctly, it will be high-cost, unreliable, and not robust. For micro products and systems it is a continuously increasing challenge to create the operational basis for an industrial production. As the products through product development...... processes are made applicable to a large number of customers, the pressure in regard to developing production technologies that make it possible to produce the products at a reasonable price and in large numbers is growing. The micro/nano manufacturing programme at the Department of Manufacturing...

  5. Changes in lens stiffness due to capsular opacification in accommodative lens refilling

    NARCIS (Netherlands)

    Nibourg, Lisanne M.; Sharma, Prashant K.; van Kooten, Theo G.; Koopmans, Steven A.

    Accommodation may be restored to presbyopic lenses by refilling the lens capsular bag with a soft polymer. After this accommodative lens refilling prevention of capsular opacification is a requirement, since capsular opacification leads to a decreased clarity of the refilled lens. It has been

  6. Exchange of tears under a contact lens is driven by distortions of the contact lens.

    Science.gov (United States)

    Maki, Kara L; Ross, David S

    2014-12-01

    We studied the flow of the post-lens tear film under a soft contact lens to understand how the design parameters of contact lenses can affect ocular health. When a soft contact lens is inserted, the blinking eyelid causes the lens to stretch in order to conform to the shape of the eye. The deformed contact lens acts to assume its un-deformed shape and thus generates a suction pressure in the post-lens tear film. In consequence, the post-lens tear fluid moves; it responds to the suction pressure. The suction pressure may draw in fresh fluid from the edge of the lens, or it may eject fluid there, as the lens reassumes its un-deformed shape. In this article, we develop a mathematical model of the flow of the post-lens tear fluid in response to the mechanical suction pressure of a deformed contact lens. We predict the amount of exchange of fluid exchange under a contact lens and we explore the influence of the eye's shape on the rate of exchange of fluid. © The Author 2014. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.

  7. Nanostructured Fiber Optic Cantilever Arrays and Hybrid MEMS Sensors for Chemical and Biological Detection, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Advancements in nano-/micro-scale sensor fabrication and molecular recognition surfaces offer promising opportunities to develop miniaturized hybrid fiber optic and...

  8. Lens design and local minima

    International Nuclear Information System (INIS)

    Brixner, B.

    1981-01-01

    The widespread belief that local minima exist in the least squares lens-design error function is not confirmed by the Los Alamos Scientific Laboratory (LASL) optimization program. LASL finds the optimum-mimimum region, which is characterized by small parameter gradients of similar size, small performance improvement per iteration, and many designs that give similar performance. Local minima and unique prescriptions have not been found in many-parameter problems. The reason for these absences is that image errors caused by a change in one parameter can be compensated by changes in the remaining parameters. False local minima have been found, and four cases are discussed

  9. [fs-Lentotomy: presbyopia reversal by generating gliding planes inside the crystalline lens].

    Science.gov (United States)

    Lubatschowski, H; Schumacher, S; Wegener, A; Fromm, M; Oberheide, U; Hoffmann, H; Gerten, G

    2009-12-01

    Based on the Helmholtz theory for accommodation, increasing sclerosis of the lens nucleus and cortex is the main cause for the development of presbyopia. Existing therapies, however, do not reverse the stiffness of the crystalline lens and thus do not regain real accommodation ability. A new approach to restore the flexibility of the lens has been realised by utilising the non-linear interaction of ultrafast laser pulses with transparent tissue, the so-called photodisruption. This process has been used to create micro-incisions which act as gliding planes inside the crystalline lens without opening the eye globe. This treatment method, known as fs-lentotomy, enables regeneration of real dynamic accommodation. For the first time, 3D structures for gliding planes were successfully generated in experiments with human donor lenses of different ages. An average increase in anterior-posterior lens thickness of 100 mum accompanied by a decrease of equatorial lens diameter was observed as a direct consequence of fs-lentotomy. This is attributed to the increased flexibility, as the force of the capsule bag moulds the lens tissue more spherically. Moreover, in vivo experiments on rabbit eye lenses did not induce an increasing opacification (cataract) over a six-month follow-up period. However, the incisions were still detectable using Scheimpflug imaging and histopathological techniques, although the visibility of the incisions was declining. Furthermore, no side effects were observed during the wound healing process and during a six-months follow-up period. Based on these findings fs-lentotomy might have the potential to become a procedure for the reversal of presbyopia. Copyright Georg Thieme Verlag KG Stuttgart . New York.

  10. Source apportionment of aerosol particles using polycapillary slightly focusing X-ray lens

    Energy Technology Data Exchange (ETDEWEB)

    Sun Tianxi [Key Laboratory of Beam Technology and Materials Modification of Ministry of Education, Beijing Normal University, Beijing 100875 (China) and Institute of Low Energy Nuclear Physics, Beijing Normal University, Beijing 100875 (China) and Beijing Radiation Center, Beijing 100875 (China)], E-mail: stxbeijing@163.com; Liu Zhiguo [Key Laboratory of Beam Technology and Materials Modification of Ministry of Education, Beijing Normal University, Beijing 100875 (China) and Institute of Low Energy Nuclear Physics, Beijing Normal University, Beijing 100875 (China) and Beijing Radiation Center, Beijing 100875 (China)], E-mail: liuzgbeijing@163.com; Zhu Guanghua; Liu Hui [Key Laboratory of Beam Technology and Materials Modification of Ministry of Education, Beijing Normal University, Beijing 100875 (China); Institute of Low Energy Nuclear Physics, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China); Ma Yongzhong [Center for Disease Control and Prevention of Beijing, Beijing 100013 (China); Xu Qing [Institute of High Energy Physics, Chinese Academy of Science, Beijing 100039 (China); Li Yude; Wang Guangpu; Luo Ping; Pan Qiuli; Ding Xunliang [Key Laboratory of Beam Technology and Materials Modification of Ministry of Education, Beijing Normal University, Beijing 100875 (China); Institute of Low Energy Nuclear Physics, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China)

    2009-06-11

    A micro-X-ray fluorescence (Micro-XRF) spectrometer based on a polycapillary slightly focusing X-ray lens (PSFXRL) and laboratory X-ray source was designed to carry out the source apportionment of aerosol particles. In the distribution curve of the X-ray intensity in the focal spot of PSFXRL, there was a plateau with a diameter of about 65 {mu}m. The uniformity of this plateau was about 3%. This was helpful in measuring the XRF spectrum of a single aerosol particle in which the element distributions are not uniform. The minimum detection limit (MDL) of this Micro-XRF spectrometer was 15 ppm for the Fe-K{sub {alpha}}. The origins of the aerosol particles at the exit of a subway station and a construction site were apportioned. This Micro-XRF spectrometer has potential applications in analysis of single aerosol particles.

  11. Primary anterior chamber intraocular lens for the treatment of severe crystalline lens subluxation.

    Science.gov (United States)

    Hoffman, Richard S; Fine, I Howard; Packer, Mark

    2009-10-01

    Subluxated cataractous and clear lenses are commonly treated by limbal or pars plana lensectomy followed by primary or secondary intraocular lens (IOL) implantation. Adjunctive capsular prosthetic devices have facilitated lens removal and IOL centration in these challenging cases but have also added complexity and potential complications to the procedure. Although crystalline lens extraction may be required to clear the visual axis in mild to moderate lens subluxations, we propose insertion of a primary anterior chamber IOL without lens extraction in severe subluxations when the eye is optically aphakic or can be made functionally aphakic following neodymium:YAG laser zonulysis. Two cases demonstrating this approach are presented.

  12. Fabricating customized hydrogel contact lens

    Science.gov (United States)

    Childs, Andre; Li, Hao; Lewittes, Daniella M.; Dong, Biqin; Liu, Wenzhong; Shu, Xiao; Sun, Cheng; Zhang, Hao F.

    2016-10-01

    Contact lenses are increasingly used in laboratories for in vivo animal retinal imaging and pre-clinical studies. The lens shapes often need modification to optimally fit corneas of individual test subjects. However, the choices from commercially available contact lenses are rather limited. Here, we report a flexible method to fabricate customized hydrogel contact lenses. We showed that the fabricated hydrogel is highly transparent, with refractive indices ranging from 1.42 to 1.45 in the spectra range from 400 nm to 800 nm. The Young’s modulus (1.47 MPa) and hydrophobicity (with a sessile drop contact angle of 40.5°) have also been characterized experimentally. Retinal imaging using optical coherence tomography in rats wearing our customized contact lenses has the quality comparable to the control case without the contact lens. Our method could significantly reduce the cost and the lead time for fabricating soft contact lenses with customized shapes, and benefit the laboratorial-used contact lenses in pre-clinical studies.

  13. Protection of the eye lens

    International Nuclear Information System (INIS)

    2015-01-01

    The limit of radiation exposure for eye lens is going to decrease dramatically from 150 to 20 mSv as a transposition into the French law of a CIPR (International Commission for Radiation Protection) directive. Sanitary studies have shown that radiologists are more likely by a factor of 3.8 to get eye lens opacities than the rest of the population. The wearing of protective glasses is recommended and in order to get a better monitoring of the radiation dose new dosimeters have been designed, they can be worn on the glass frame of directly stuck on the skin near the eyes. A study has shown that veterinary surgeons that are accustomed to stay near animals to keep them quiet during radiological exams are prone to receive high doses as well as physicians that use hypnosis to decrease the level of anxiety of their patients during radiological exams. Radiation exposure of radiologists can be mitigated through: the use of protective shields and equipment and the optimization of the dose delivered to the patient. (A.C.)

  14. Color corrected Fresnel lens for solar concentration

    International Nuclear Information System (INIS)

    Kritchman, E.M.

    1979-01-01

    A new linear convex Fresnel lens with its groove side down is described. The design philosophy is similar to the highly concentrating two focal Fresnel lens but including a correction for chromatic aberration. A solar concentration ratio as high as 80 is achieved. For wide acceptance angles the concentration nears the theoretical maximum. (author)

  15. Analysis of a Thin Optical Lens Model

    Science.gov (United States)

    Ivchenko, Vladimir V.

    2011-01-01

    In this article a thin optical lens model is considered. It is shown that the limits of its applicability are determined not only by the ratio between the thickness of the lens and the modules of the radii of curvature, but above all its geometric type. We have derived the analytical criteria for the applicability of the model for different types…

  16. Mathematical Lens: How Much Can You Bench?

    Science.gov (United States)

    Bolognese, Chris A.

    2013-01-01

    "How Much Can You Bench?" appears in the "Mathematical Lens" section of "Mathematics Teacher." "Mathematical Lens" uses photographs as a springboard for mathematical inquiry and appears in every issue of "Mathematics Teacher." This month the mathematics behind the photograph includes finding areas…

  17. Plasma Lens for Muon and Neutrino Beams

    International Nuclear Information System (INIS)

    Kahn, S.A.; Korenev, S.; Bishai, M.; Diwan, M.; Gallardo, J.C.; Hershcovitch, A.; Johnson, B.M.

    2008-01-01

    The plasma lens is examined as an alternate to focusing horns and solenoids for use in a neutrino or muon beam facility. The plasma lens concept is based on a combined high-energy lens/target configuration. The current is fed at electrodes located upstream and downstream from the target where pion capturing is needed. The current flows primarily in the plasma, which has a lower resistivity than the target. A second plasma lens section, with an additional current feed, follows the target to provide shaping of the plasma for optimum focusing. The plasma lens is immersed in an additional solenoid magnetic field to facilitate the plasma stability. The geometry of the plasma is shaped to provide optimal pion capture. Simulations of this plasma lens system have shown a 25% higher neutrino production than the horn system. Plasma lenses have the additional advantage of negligible pion absorption and scattering by the lens material and reduced neutrino contamination during anti-neutrino running. Results of particle simulations using plasma lens will be presented

  18. LensEnt2: Maximum-entropy weak lens reconstruction

    Science.gov (United States)

    Marshall, P. J.; Hobson, M. P.; Gull, S. F.; Bridle, S. L.

    2013-08-01

    LensEnt2 is a maximum entropy reconstructor of weak lensing mass maps. The method takes each galaxy shape as an independent estimator of the reduced shear field and incorporates an intrinsic smoothness, determined by Bayesian methods, into the reconstruction. The uncertainties from both the intrinsic distribution of galaxy shapes and galaxy shape estimation are carried through to the final mass reconstruction, and the mass within arbitrarily shaped apertures are calculated with corresponding uncertainties. The input is a galaxy ellipticity catalog with each measured galaxy shape treated as a noisy tracer of the reduced shear field, which is inferred on a fine pixel grid assuming positivity, and smoothness on scales of w arcsec where w is an input parameter. The ICF width w can be chosen by computing the evidence for it.

  19. Laser beam micro-milling of micro-channels in aerospace alloys

    CERN Document Server

    Ahmed, Naveed; Al-Ahmari, Abdulrahman

    2017-01-01

    This volume is greatly helpful to micro-machining and laser engineers as it offers obliging guidelines about the micro-channel fabrications through Nd:YAG laser beam micro-milling. The book also demonstrates how the laser beam micro-milling behaves when operating under wet conditions (under water), and explores what are the pros and cons of this hybrid technique. From the predictive mathematical models, the readers can easily estimate the resulting micro-channel size against the desired laser parametric combinations. The book considers micro-channels in three highly important research materials commonly used in aerospace industry: titanium alloy Ti-6Al-4V, nickel alloy Inconel 718 and aluminum alloy AA 2024. Therefore, the book is highly practicable in the fields of micro-channel heat exchangers, micro-channel aerospace turbine blades, micro-channel heat pipes, micro-coolers and micro-channel pulsating heat plates. These are frequently used in various industries such as aerospace, automotive, biomedical and m...

  20. Activity patterns of cultured neural networks on micro electrode arrays

    NARCIS (Netherlands)

    Rutten, Wim; van Pelt, J.

    2001-01-01

    A hybrid neuro-electronic interface is a cell-cultured micro electrode array, acting as a neural information transducer for stimulation and/or recording of neural activity in the brain or the spinal cord (ventral motor region or dorsal sensory region). It consists of an array of micro electrodes on

  1. Micro Programming

    OpenAIRE

    Spanjersberg , Herman

    2012-01-01

    International audience; In the 1970s a need arose to perform special arithmetic operations on minicomputers much more quickly than had been possible in the past. This paper tells the story of why micro programming was needed for special arithmetic operations on mini computers in the 1970s and how it was implemented. The paper tells how the laboratory in which the first experiment took place had a PDP-9 minicomputer from Digital Equipment Corporation and how the author, with several colleagues...

  2. Lessons learned: wrong intraocular lens.

    Science.gov (United States)

    Schein, Oliver D; Banta, James T; Chen, Teresa C; Pritzker, Scott; Schachat, Andrew P

    2012-10-01

    To report cases involving the placement of the wrong intraocular lens (IOL) at the time of cataract surgery where human error occurred. Retrospective small case series, convenience sample. Seven surgical cases. Institutional review of errors committed and subsequent improvements to clinical protocols. Lessons learned and changes in procedures adapted. The pathways to a wrong IOL are many but largely reflect some combination of poor surgical team communication, transcription error, lack of preoperative clarity in surgical planning or failure to match the patient, and IOL calculation sheet with 2 unique identifiers. Safety in surgery involving IOLs is enhanced both by strict procedures, such as an IOL-specific "time-out," and the fostering of a surgical team culture in which all members are encouraged to voice questions and concerns. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  3. Radiation studies in Lens culinaris

    International Nuclear Information System (INIS)

    Sinha, S.S.N.

    1977-01-01

    Estimation of chromosomal aberrations in flowers of Lens culinaris according to their sequence of development in the plants at 4, 8 and 12 Kr in the M 1 generation, showed that the later formed flowers had smaller percentages of cells with aberrations than those developed earlier. It is suggested that this may be the result of competition between more damaged and less damaged cells during the development of the shoot. There is consequently a decrease of sterility in successive flowers. The numbers of karyotypes taking part in the formation of lower and uppermost flowers were estimated cytologically at 4, 8 and 12 Kr. It was found that more karyotypes were involved in the formation of the lower flowers than in the upper ones. It appeared that at lower doses larger numbers of karyotypes were taking part in the formation of the chimaera than at higher doses. (auth.)

  4. Precision lens assembly with alignment turning system

    Science.gov (United States)

    Ho, Cheng-Fang; Huang, Chien-Yao; Lin, Yi-Hao; Kuo, Hui-Jean; Kuo, Ching-Hsiang; Hsu, Wei-Yao; Chen, Fong-Zhi

    2017-10-01

    The poker chip assembly with high precision lens barrels is widely applied to ultra-high performance optical system. ITRC applies the poker chip assembly technology to the high numerical aperture objective lenses and lithography projection lenses because of its high efficiency assembly process. In order to achieve high precision lens cell for poker chip assembly, an alignment turning system (ATS) is developed. The ATS includes measurement, alignment and turning modules. The measurement module is equipped with a non-contact displacement sensor (NCDS) and an autocollimator (ACM). The NCDS and ACM are used to measure centration errors of the top and the bottom surface of a lens respectively; then the amount of adjustment of displacement and tilt with respect to the rotational axis of the turning machine for the alignment module can be determined. After measurement, alignment and turning processes on the ATS, the centration error of a lens cell with 200 mm in diameter can be controlled within 10 arcsec. Furthermore, a poker chip assembly lens cell with three sub-cells is demonstrated, each sub-cells are measured and accomplished with alignment and turning processes. The lens assembly test for five times by each three technicians; the average transmission centration error of assembly lens is 12.45 arcsec. The results show that ATS can achieve high assembly efficiency for precision optical systems.

  5. Bioinspired adaptive gradient refractive index distribution lens

    Science.gov (United States)

    Yin, Kezhen; Lai, Chuan-Yar; Wang, Jia; Ji, Shanzuo; Aldridge, James; Feng, Jingxing; Olah, Andrew; Baer, Eric; Ponting, Michael

    2018-02-01

    Inspired by the soft, deformable human eye lens, a synthetic polymer gradient refractive index distribution (GRIN) lens with an adaptive geometry and focal power has been demonstrated via multilayer coextrusion and thermoforming of nanolayered elastomeric polymer films. A set of 30 polymer nanolayered films comprised of two thermoplastic polyurethanes having a refractive index difference of 0.05 were coextruded via forced-assembly technique. The set of 30 nanolayered polymer films exhibited transmission near 90% with each film varying in refractive index by 0.0017. An adaptive GRIN lens was fabricated from a laminated stack of the variable refractive index films with a 0.05 spherical GRIN. This lens was subsequently deformed by mechanical ring compression of the lens. Variation in the optical properties of the deformable GRIN lens was determined, including 20% variation in focal length and reduced spherical aberration. These properties were measured and compared to simulated results by placido-cone topography and ANSYS methods. The demonstration of a solid-state, dynamic focal length, GRIN lens with improved aberration correction was discussed relative to the potential future use in implantable devices.

  6. Design of a hyperbolic microwave metallic lens

    International Nuclear Information System (INIS)

    Uckan, T.

    1979-12-01

    Due to problems caused by multiple reflections in the cavity walls of the EBT fusion research device, the use of a horn becomes important for the directivity of waves in the millimetric range. An ordinary dielectric lens cannot be used because of plasma-wall interactions. Microwave metallic lenses, designed to focus the energy into a plane wave, can improve the directivity considerably. By implementing a 70-GHz standard-gain horn with a delay-type hyperbolic lens, which consists of a solid metallic disk with a number of equal size small holes has indicated a gain of 15 dB over the no lens case

  7. Accelerating convergence in automatic lens design

    International Nuclear Information System (INIS)

    Brixner, B.

    1981-01-01

    Among the various factors that slow lens optimization-insufficient performance targets, the absence of a unique solution, false local minima, a poorly scaled change vector, failure to find the optimum damping number, and failure to equalize the parameter gradients-the importance of parameter gradient equalization has been insufficiently recognized. Gradients can be approximately equalized by scaling the lens to a suitable size while it is being optimized. For best results, the size of the damping number should also be optimized during each iteration. If these two procedures are followed, scaling the change vector is usually not crucial. To illustrate the importance of parameter equalization, a lens optimization is analyzed

  8. 21 CFR 886.1395 - Diagnostic Hruby fundus lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Diagnostic Hruby fundus lens. 886.1395 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1395 Diagnostic Hruby fundus lens. (a) Identification. A diagnostic Hruby fundus lens is a device that is a 55 diopter lens intended for use in the...

  9. 21 CFR 886.5844 - Prescription spectacle lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prescription spectacle lens. 886.5844 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5844 Prescription spectacle lens. (a) Identification. A prescription spectacle lens is a glass or plastic device that is a lens intended to be worn by...

  10. 21 CFR 886.1390 - Flexible diagnostic Fresnel lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Flexible diagnostic Fresnel lens. 886.1390 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1390 Flexible diagnostic Fresnel lens. (a) Identification. A flexible diagnostic Fresnel lens is a device that is a very thin lens which has...

  11. Visualization of femtosecond laser pulse-induced microincisions inside crystalline lens tissue.

    Science.gov (United States)

    Stachs, Oliver; Schumacher, Silvia; Hovakimyan, Marine; Fromm, Michael; Heisterkamp, Alexander; Lubatschowski, Holger; Guthoff, Rudolf

    2009-11-01

    To evaluate a new method for visualizing femtosecond laser pulse-induced microincisions inside crystalline lens tissue. Laser Zentrum Hannover e.V., Hannover, Germany. Lenses removed from porcine eyes were modified ex vivo by femtosecond laser pulses (wavelength 1040 nm, pulse duration 306 femtoseconds, pulse energy 1.0 to 2.5 microJ, repetition rate 100 kHz) to create defined planes at which lens fibers separate. The femtosecond laser pulses were delivered by a 3-dimension (3-D) scanning unit and transmitted by focusing optics (numerical aperture 0.18) into the lens tissue. Lens fiber orientation and femtosecond laser-induced microincisions were examined using a confocal laser scanning microscope (CLSM) based on a Rostock Cornea Module attached to a Heidelberg Retina Tomograph II. Optical sections were analyzed in 3-D using Amira software (version 4.1.1). Normal lens fibers showed a parallel pattern with diameters between 3 microm and 9 microm, depending on scanning location. Microincision visualization showed different cutting effects depending on pulse energy of the femtosecond laser. The effects ranged from altered tissue-scattering properties with all fibers intact to definite fiber separation by a wide gap. Pulse energies that were too high or overlapped too tightly produced an incomplete cutting plane due to extensive microbubble generation. The 3-D CLSM method permitted visualization and analysis of femtosecond laser pulse-induced microincisions inside crystalline lens tissue. Thus, 3-D CLSM may help optimize femtosecond laser-based procedures in the treatment of presbyopia.

  12. On the isolation of elemental carbon (EC) for micro-molar 14C accelerator mass spectrometry: development of a hybrid reference material for 14C-EC accuracy assurance, and a critical evaluation of the thermal optical kinetic (TOK) EC isolation procedure

    Science.gov (United States)

    Currie, L. A.; Kessler, J. D.

    2005-10-01

    The primary objective of the research reported here has been the development of a hybrid reference material (RM) to serve as a test of accuracy for elemental carbon (EC) isotopic (14C) speciation measurements. Such measurements are vital for the quantitative apportionment of fossil and biomass sources of "soot" (EC), the tracer of fire that has profound effects on health, atmospheric visibility, and climate. Previous studies of 14C-EC measurement quality, carried out with NIST SRM 1649a (Urban Dust), showed a range of results, but since the "truth" was not known for this natural matrix RM, one had to rely on isotopic-chemical consistency evidence (14C in PAH, EC) of measurement validity (Currie et al., 2002). Components of the new Hybrid RM (DiesApple), however, have known 14C and EC composition, and they are nearly orthogonal (isotopically and chemically). NIST SRM 2975 (Forklift Diesel Soot) has little or no 14C, and its major compositional component is EC; SRM 1515 (Apple Leaves) has the 14C content of biomass-C, and it has little or no EC. Thus, the Hybrid RM can serve as an absolute isotopic test for the absence of EC-mimicking pyrolysis-C (char) from SRM 1515 in the EC isolate of the Hybrid RM, as well as a test for conservation of its dominant soot fraction throughout the isolation procedure. The secondary objective was to employ the Hybrid RM for the comparative evaluation of the thermal optical kinetic (TOK) and thermal optical transmission (TOT) methods for the isolation of EC for micro-molar carbon accelerator mass spectrometry (AMS). As part of this process, the relatively new TOK method was subjected to a critical evaluation and significant development. Key findings of our study are: (1) both methods exhibited biomass-C "leakage"; for TOT, the EC fraction isolated for AMS contained about 8% of the original biomass-C; for TOK, the refractory carbon (RC) isolated contained about 3% of the original biomass-C.; (2) the initial isothermal oxidation stage of

  13. On the isolation of elemental carbon (EC for micro-molar 14C accelerator mass spectrometry: development of a hybrid reference material for 14C-EC accuracy assurance, and a critical evaluation of the thermal optical kinetic (TOK EC isolation procedure

    Directory of Open Access Journals (Sweden)

    L. A. Currie

    2005-01-01

    Full Text Available The primary objective of the research reported here has been the development of a hybrid reference material (RM to serve as a test of accuracy for elemental carbon (EC isotopic (14C speciation measurements. Such measurements are vital for the quantitative apportionment of fossil and biomass sources of 'soot' (EC, the tracer of fire that has profound effects on health, atmospheric visibility, and climate. Previous studies of 14C-EC measurement quality, carried out with NIST SRM 1649a (Urban Dust, showed a range of results, but since the 'truth' was not known for this natural matrix RM, one had to rely on isotopic-chemical consistency evidence (14C in PAH, EC of measurement validity (Currie et al., 2002. Components of the new Hybrid RM (DiesApple, however, have known 14C and EC composition, and they are nearly orthogonal (isotopically and chemically. NIST SRM 2975 (Forklift Diesel Soot has little or no 14C, and its major compositional component is EC; SRM 1515 (Apple Leaves has the 14C content of biomass-C, and it has little or no EC. Thus, the Hybrid RM can serve as an absolute isotopic test for the absence of EC-mimicking pyrolysis-C (char from SRM 1515 in the EC isolate of the Hybrid RM, as well as a test for conservation of its dominant soot fraction throughout the isolation procedure. The secondary objective was to employ the Hybrid RM for the comparative evaluation of the thermal optical kinetic (TOK and thermal optical transmission (TOT methods for the isolation of EC for micro-molar carbon accelerator mass spectrometry (AMS. As part of this process, the relatively new TOK method was subjected to a critical evaluation and significant development. Key findings of our study are: (1 both methods exhibited biomass-C 'leakage'; for TOT, the EC fraction isolated for AMS contained about 8% of the original biomass-C; for TOK, the refractory carbon (RC isolated contained about 3% of the original biomass-C.; (2 the initial isothermal oxidation stage

  14. Hybrid reactors

    International Nuclear Information System (INIS)

    Moir, R.W.

    1980-01-01

    The rationale for hybrid fusion-fission reactors is the production of fissile fuel for fission reactors. A new class of reactor, the fission-suppressed hybrid promises unusually good safety features as well as the ability to support 25 light-water reactors of the same nuclear power rating, or even more high-conversion-ratio reactors such as the heavy-water type. One 4000-MW nuclear hybrid can produce 7200 kg of 233 U per year. To obtain good economics, injector efficiency times plasma gain (eta/sub i/Q) should be greater than 2, the wall load should be greater than 1 MW.m -2 , and the hybrid should cost less than 6 times the cost of a light-water reactor. Introduction rates for the fission-suppressed hybrid are usually rapid

  15. Measurement of Crystalline Lens Volume During Accommodation in a Lens Stretcher.

    Science.gov (United States)

    Marussich, Lauren; Manns, Fabrice; Nankivil, Derek; Maceo Heilman, Bianca; Yao, Yue; Arrieta-Quintero, Esdras; Ho, Arthur; Augusteyn, Robert; Parel, Jean-Marie

    2015-07-01

    To determine if the lens volume changes during accommodation. The study used data acquired on 36 cynomolgus monkey lenses that were stretched in a stepwise fashion to simulate disaccommodation. At each step, stretching force and dioptric power were measured and a cross-sectional image of the lens was acquired using an optical coherence tomography system. Images were corrected for refractive distortions and lens volume was calculated assuming rotational symmetry. The average change in lens volume was calculated and the relation between volume change and power change, and between volume change and stretching force, were quantified. Linear regressions of volume-power and volume-force plots were calculated. The mean (± SD) volume in the unstretched (accommodated) state was 97 ± 8 mm3. On average, there was a small but statistically significant (P = 0.002) increase in measured lens volume with stretching. The mean change in lens volume was +0.8 ± 1.3 mm3. The mean volume-power and volume-load slopes were -0.018 ± 0.058 mm3/D and +0.16 ± 0.40 mm3/g. Lens volume remains effectively constant during accommodation, with changes that are less than 1% on average. This result supports a hypothesis that the change in lens shape with accommodation is accompanied by a redistribution of tissue within the capsular bag without significant compression of the lens contents or fluid exchange through the capsule.

  16. AutoLens: Automated Modeling of a Strong Lens's Light, Mass and Source

    Science.gov (United States)

    Nightingale, J. W.; Dye, S.; Massey, Richard J.

    2018-05-01

    This work presents AutoLens, the first entirely automated modeling suite for the analysis of galaxy-scale strong gravitational lenses. AutoLens simultaneously models the lens galaxy's light and mass whilst reconstructing the extended source galaxy on an adaptive pixel-grid. The method's approach to source-plane discretization is amorphous, adapting its clustering and regularization to the intrinsic properties of the lensed source. The lens's light is fitted using a superposition of Sersic functions, allowing AutoLens to cleanly deblend its light from the source. Single component mass models representing the lens's total mass density profile are demonstrated, which in conjunction with light modeling can detect central images using a centrally cored profile. Decomposed mass modeling is also shown, which can fully decouple a lens's light and dark matter and determine whether the two component are geometrically aligned. The complexity of the light and mass models are automatically chosen via Bayesian model comparison. These steps form AutoLens's automated analysis pipeline, such that all results in this work are generated without any user-intervention. This is rigorously tested on a large suite of simulated images, assessing its performance on a broad range of lens profiles, source morphologies and lensing geometries. The method's performance is excellent, with accurate light, mass and source profiles inferred for data sets representative of both existing Hubble imaging and future Euclid wide-field observations.

  17. Placement of a crystalline lens and intraocular lens: Retinal image quality.

    Science.gov (United States)

    Siedlecki, Damian; Nowak, Jerzy; Zajac, Marek

    2006-01-01

    The influence of changes of both crystalline lens and intraocular lens (IOL) misalignment on the retinal image quality was investigated. The optical model of the eye used in investigations was the Liou-Brennan model, which is commonly considered as one of the most anatomically accurate. The original crystalline lens from this model was replaced with an IOL, made of rigid polymethylmethacrylate, in a way that recommend obligatory procedures. The modifications that were made both for crystalline lens and IOL were the longitudinal, the transversal, and the angular displacement.

  18. Development of Fresnel lens for improvement of rear visibility; Shikai kojo Fresnel lens no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Iwamoto, K; Sanada, C; Tsukino, M [Nissan Motor Co. Ltd., Tokyo (Japan)

    1997-10-01

    Fresnel lenses have been widely used to increase the visual field around vehicles for drivers. However, internal reflection in these lenses has been an obstacle in producing dear images. This internal glow is generated by incident light from an unexpected direction reflecting on the non-lens surface or radiating from the non-lens surface of the Fresnel lens. The cause of internal glow has been made dear combining louver film with the lens. The newly developed technology removes obstacles in producing dear images by reducing internal glow. 7 figs.

  19. Disinfection capacity of PuriLens contact lens cleaning unit against Acanthamoeba.

    Science.gov (United States)

    Hwang, Thomas S; Hyon, Joon Young; Song, Jae Kyung; Reviglio, Victor E; Spahr, Harry T; O'Brien, Terrence P

    2004-01-01

    The PuriLens contact lens system is indicated for cleaning and disinfection of soft (hydrophilic) contact lenses by means of subsonic agitation to remove lens deposits and microorganisms, and ultraviolet irradiation of the storage solution for disinfection. The capacity of the PuriLens system to disinfect storage solutions contaminated with known concentrations of Staphylococcus aureus, Pseudomonas aeruginosa, and Acanthamoeba species was evaluated. An in vitro assessment of the antibacterial and antiparasitic efficacy of the PuriLens system was performed. Separated batches of the storage solution for the cleansing system were contaminated with stock strains of S. aureus and P. aeruginosa. A comparison of the microbiologic content was made between the solution before and after the cycle. The PuriLens system effectively eradicated S. aureus and P. aeruginosa organisms after a 15-minute cycle. However, viable cysts of acanthamoeba were recovered in the solution after the 15-minute cycle. The PuriLens system is highly efficient in protecting against contamination with common bacterial ocular pathogens. Acanthamoeba cysts, however, can survive in the solution or contact lens bath undergoing integrated subsonic debridement and indirect ultraviolet light disinfection. Use of chemical disinfecting solutions that contain agents such as chlorhexidine or other cationic antiseptics may be advisable in conjunction with use of the PuriLens device, especially in high-risk settings.

  20. Night Vision Goggles Objectives Lens Focusing Methodology

    National Research Council Canada - National Science Library

    Pinkus, Alan; Task, H. L

    2000-01-01

    ...: interpupillary distance, tilt, eye relief, height, eyepiece and objective lens focus. Currently, aircrew use a Hoffman 20/20 test unit to pre-focus their NVG objective lenses at optical infinity before boarding their aircraft...

  1. Characteristics of soft X-ray lens

    International Nuclear Information System (INIS)

    Qin Yi

    2007-12-01

    A soft X-lens was devised with waveguide X-ray optics of total external reflection (TER). The lens consists of a stack of 1 387 TER waveguides with inner diameter of 0.45 mm and outer diameter of 0.60 mm. With the help of plasma sources of soft X-ray radiation, high density of pure soft X-ray radiation (without plasma expansion fragments) with broad-band spectral range can be obtained at the focus of the lens. As laser-plasma is considered, the radiation density of 1.3 x 10 5 W/cm 2 is obtained, the transmission coefficient is 18.6%, the ratio of the density at the focus with and without the lens is 1000 and the radiation capture is 28.9 degree. The density of 0.5 TW/cm 2 can be obtained as far as Qiang-Guang I facility is considered. (authors)

  2. Gravitational lens effect and pregalactic halo objects

    International Nuclear Information System (INIS)

    Bontz, R.J.

    1979-01-01

    The changes in flux, position, and size of a distant extended (galaxy, etc.) source that result from the gravitational lens action of a massive opaque object are discussed. The flux increase is described by a single function of two parameters. One of these parameters characterizes the strength of the gravitational lens, the other describes the alignment of source and lens object. This function also describes the relative intensity of the images formed by lens. ( A similar formalism is discussed by Bourassa et al. for a point source). The formalism is applied to the problem of the galactic halo. It appears that a massive (10 1 2 M/sub sun/) spherical halo surrounding the visible part of the galaxy is consistent with the observable properties of extragalactic sources

  3. Discovery of two new gravitation lens systems

    International Nuclear Information System (INIS)

    Guertler, J.

    1988-01-01

    The discovery of new quasar and radio galaxy double images produced by the gravitation lens effect is reported. The light deflecting galaxies acting as gravitational lenses could be made visible by means of image processing procedures

  4. A Plasma Lens for Magnetron Sputtering

    International Nuclear Information System (INIS)

    Anders, Andre; Brown, Jeff

    2010-01-01

    A plasma lens, consisting of a solenoid and potential-defining ring electrodes, has been placed between a magnetron and substrates to be coated. Photography reveals qualitative information on excitation, ionization, and the transport of plasma to the substrate.

  5. The discovery of a gravitational lens

    International Nuclear Information System (INIS)

    Chaffee, F.H. Jr.

    1981-01-01

    A recently discovered pair of quasars turns out to be not a pair at all but two images of a single quasar formed by a gravitational lens: an elliptical galaxy halfway between the quasar and our own galaxy. (orig.) [de

  6. EDEL: ENEA dosemeter for eye lens

    International Nuclear Information System (INIS)

    Ferrari, Paolo; Mariotti, Francesca; Campani, Lorenzo

    2016-01-01

    Since the publication of International Commission on Radiological Protection statement in 2011 on tissue reaction, eye lens radiation protection played an important role in exposed personnel dosimetry. For this reason, the Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA) Individual Monitoring Service decided to study a prototype to fulfil specific requests (e.g. for survey in interventional department and intercomparisons). On the basis of such preliminary investigation, a new eye lens dosemeter was developed. The new dosemeter, named EDEL (ENEA Dosemeter for Eye Lens), was characterised in terms of H p (3), the operational quantity related to eye lens monitoring. The investigation was performed experimentally and optimised using the Monte Carlo MCNP6 code. The new prototype was thought to fulfil two main requests: the reliability of the dosimetric data and the portability of the dosemeter itself. The new dosemeter will soon be supplied to the collaborating hospitals for workplace test measurements. (authors)

  7. Role of Aquaporin 0 in lens biomechanics

    Energy Technology Data Exchange (ETDEWEB)

    Sindhu Kumari, S.; Gupta, Neha [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); Shiels, Alan [Washington University School of Medicine, St. Louis, MO (United States); FitzGerald, Paul G. [Cell Biology and Human Anatomy, School of Medicine, University of California, Davis, CA (United States); Menon, Anil G. [University of Cincinnati College of Medicine, Cincinnati, OH (United States); Mathias, Richard T. [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States); Varadaraj, Kulandaiappan, E-mail: kulandaiappan.varadaraj@stonybrook.edu [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States)

    2015-07-10

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5{sup −/−}), AQP0 KO (heterozygous KO: AQP0{sup +/−}; homozygous KO: AQP0{sup −/−}; all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0{sup +/−} lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and

  8. Role of Aquaporin 0 in lens biomechanics.

    Science.gov (United States)

    Sindhu Kumari, S; Gupta, Neha; Shiels, Alan; FitzGerald, Paul G; Menon, Anil G; Mathias, Richard T; Varadaraj, Kulandaiappan

    2015-07-10

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5(-/-)), AQP0 KO (heterozygous KO: AQP0(+/-); homozygous KO: AQP0(-/-); all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0(+/-) lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and together they help to confer

  9. Evolution and the Calcite Eye Lens

    OpenAIRE

    Williams, Vernon L.

    2013-01-01

    Calcite is a uniaxial, birefringent crystal, which in its optically transparent form, has been used for animal eye lenses, the trilobite being one such animal. Because of the calcite birefringence there is a difficulty in using calcite as a lens. When the propagation direction of incoming light is not exactly on the c-axis, the mages blur. In this paper, calcite blurring is evaluated, and the non-blurring by a crystallin eye lens is compared to a calcite one.

  10. Lens Design Using Group Indices of Refraction

    Science.gov (United States)

    Vaughan, A. H.

    1995-01-01

    An approach to lens design is described in which the ratio of the group velocity to the speed of light (the group index) in glass is used, in conjunction with the more familiar phase index of refraction, to control certain chromatic properties of a system of thin lenses in contact. The first-order design of thin-lens systems is illustrated by examples incorporating the methods described.

  11. Orbiting objective lens telescope system and method

    International Nuclear Information System (INIS)

    Crooks, J.W. Jr.

    1984-01-01

    A large objective lens is placed in a highly eccentric orbit about the earth. The orbit and orientation of the lens are carefully chosen so that it focuses light or other radiation from a preselected astronomical object into an image which slowly moves across the surface of the earth. A row of optical sensing units is located on the surface of the earth so that the image focused by the orbiting objective lens will travel substantially perpendicularly across the row during an observation. Output data generated from the sensing units may be multiplexed and fed to a real time processor which produces display signals. Each of the sensing units provides one scan line of the image being observed. The display signals are fed to a suitable display device which produces a picture of the preselected astronomical object. The objective lens may comprise a large flexible Fresnel zone plate or a flexible convex lens carried by a bicycle wheel-type supporting structure. The lens and supporting structure may be unfolded from compact cargo configurations and rotated after being placed into orbit

  12. Photon nanojet lens: design, fabrication and characterization

    International Nuclear Information System (INIS)

    Xu, Chen; Zhang, Sichao; Shao, Jinhai; Lu, Bing-Rui; Chen, Yifang; Mehfuz, Reyad; Drakeley, Stacey; Huang, Fumin

    2016-01-01

    In this paper, a novel nanolens with super resolution, based on the photon nanojet effect through dielectric nanostructures in visible wavelengths, is proposed. The nanolens is made from plastic SU-8, consisting of parallel semi-cylinders in an array. This paper focuses on the lens designed by numerical simulation with the finite-difference time domain method and nanofabrication of the lens by grayscale electron beam lithography combined with a casting/bonding/lift-off transfer process. Monte Carlo simulation for injected charge distribution and development modeling was applied to define the resultant 3D profile in PMMA as the template for the lens shape. After the casting/bonding/lift-off process, the fabricated nanolens in SU-8 has the desired lens shape, very close to that of PMMA, indicating that the pattern transfer process developed in this work can be reliably applied not only for the fabrication of the lens but also for other 3D nanopatterns in general. The light distribution through the lens near its surface was initially characterized by a scanning near-field optical microscope, showing a well defined focusing image of designed grating lines. Such focusing function supports the great prospects of developing a novel nanolithography based on the photon nanojet effect. (paper)

  13. Contact lens rehabilitation following repaired corneal perforations

    Science.gov (United States)

    Titiyal, Jeewan S; Sinha, Rajesh; Sharma, Namrata; Sreenivas, V; Vajpayee, Rasik B

    2006-01-01

    Background Visual outcome following repair of post-traumatic corneal perforation may not be optimal due to presence of irregular keratometric astigmatism. We performed a study to evaluate and compare rigid gas permeable contact lens and spectacles in visual rehabilitation following perforating corneal injuries. Method Eyes that had undergone repair for corneal perforating injuries with or without lens aspiration were fitted rigid gas permeable contact lenses. The fitting pattern and the improvement in visual acuity by contact lens over spectacle correction were noted. Results Forty eyes of 40 patients that had undergone surgical repair of posttraumatic corneal perforations were fitted rigid gas permeable contact lenses for visual rehabilitation. Twenty-four eyes (60%) required aphakic contact lenses. The best corrected visual acuity (BCVA) of ≥ 6/18 in the snellen's acuity chart was seen in 10 (25%) eyes with spectacle correction and 37 (92.5%) eyes with the use of contact lens (p < 0.001). The best-corrected visual acuity with spectacles was 0.20 ± 0.13 while the same with contact lens was 0.58 ± 0.26. All the patients showed an improvement of ≥ 2 lines over spectacles in the snellen's acuity chart with contact lens. Conclusion Rigid gas permeable contact lenses are better means of rehabilitation in eyes that have an irregular cornea due to scars caused by perforating corneal injuries. PMID:16536877

  14. Thermal Lens Spectroscopy as a 'new' analytical tool for actinide determination in nuclear reprocessing processes

    International Nuclear Information System (INIS)

    Canto, Fabrice; Couston, Laurent; Magnaldo, Alastair; Broquin, Jean-Emmanuel; Signoret, Philippe

    2008-01-01

    Thermal Lens Spectroscopy (TLS) consists of measuring the effects induced by the relaxation of molecules excited by photons. Twenty years ago, the Cea already worked on TLS. Technologic reasons impeded. But, needs in sensitive analytical methods coupled with very low sample volumes (for example, traces of Np in the COEX TM process) and also the reduction of the nuclear wastes encourage us to revisit this method thanks to the improvement of optoelectronic technologies. We can also imagine coupling TLS with micro-fluidic technologies, decreasing significantly the experiments cost. Generally two laser beams are used for TLS: one for the selective excitation by molecular absorption (inducing the thermal lens) and one for probing the thermal lens. They can be coupled with different geometries, collinear or perpendicular, depending on the application and on the laser mode. Also, many possibilities of measurement have been studied to detect the thermal lens signal: interferometry, direct intensities variations, deflection etc... In this paper, one geometrical configuration and two measurements have been theoretically evaluated. For a single photodiode detection (z-scan) the limit of detection is calculated to be near 5*10 -6 mol*L -1 for Np(IV) in dodecane. (authors)

  15. Conservation through the economics lens.

    Science.gov (United States)

    Farley, Joshua

    2010-01-01

    Although conservation is an inherently transdisciplinary issue, there is much to be gained from examining the problem through an economics lens. Three benefits of such an approach are laid out in this paper. First, many of the drivers of environmental degradation are economic in origin, and the better we understand them, the better we can conserve ecosystems by reducing degradation. Second, economics offers us a when-to-stop rule, which is equivalent to a when-to-conserve rule. All economic production is based on the transformation of raw materials provided by nature. As the economic system grows in physical size, it necessarily displaces and degrades ecosystems. The marginal benefits of economic growth are diminishing, and the marginal costs of ecological degradation are increasing. Conceptually, we should stop economic growth and focus on conservation when the two are equal. Third, economics can help us understand how to efficiently and justly allocate resources toward conservation, and this paper lays out some basic principles for doing so. Unfortunately, the field of economics is dominated by neoclassical economics, which builds an analytical framework based on questionable assumptions and takes an excessively disciplinary and formalistic approach. Conservation is a complex problem, and analysis from individual disciplinary lenses can make important contributions to conservation only when the resulting insights are synthesized into a coherent vision of the whole. Fortunately, there are a number of emerging transdisciplines, such as ecological economics and environmental management, that are dedicated to this task.

  16. Hybrid spectral CT reconstruction.

    Directory of Open Access Journals (Sweden)

    Darin P Clark

    Full Text Available Current photon counting x-ray detector (PCD technology faces limitations associated with spectral fidelity and photon starvation. One strategy for addressing these limitations is to supplement PCD data with high-resolution, low-noise data acquired with an energy-integrating detector (EID. In this work, we propose an iterative, hybrid reconstruction technique which combines the spectral properties of PCD data with the resolution and signal-to-noise characteristics of EID data. Our hybrid reconstruction technique is based on an algebraic model of data fidelity which substitutes the EID data into the data fidelity term associated with the PCD reconstruction, resulting in a joint reconstruction problem. Within the split Bregman framework, these data fidelity constraints are minimized subject to additional constraints on spectral rank and on joint intensity-gradient sparsity measured between the reconstructions of the EID and PCD data. Following a derivation of the proposed technique, we apply it to the reconstruction of a digital phantom which contains realistic concentrations of iodine, barium, and calcium encountered in small-animal micro-CT. The results of this experiment suggest reliable separation and detection of iodine at concentrations ≥ 5 mg/ml and barium at concentrations ≥ 10 mg/ml in 2-mm features for EID and PCD data reconstructed with inherent spatial resolutions of 176 μm and 254 μm, respectively (point spread function, FWHM. Furthermore, hybrid reconstruction is demonstrated to enhance spatial resolution within material decomposition results and to improve low-contrast detectability by as much as 2.6 times relative to reconstruction with PCD data only. The parameters of the simulation experiment are based on an in vivo micro-CT experiment conducted in a mouse model of soft-tissue sarcoma. Material decomposition results produced from this in vivo data demonstrate the feasibility of distinguishing two K-edge contrast agents with

  17. Hybrid spectral CT reconstruction

    Science.gov (United States)

    Clark, Darin P.

    2017-01-01

    Current photon counting x-ray detector (PCD) technology faces limitations associated with spectral fidelity and photon starvation. One strategy for addressing these limitations is to supplement PCD data with high-resolution, low-noise data acquired with an energy-integrating detector (EID). In this work, we propose an iterative, hybrid reconstruction technique which combines the spectral properties of PCD data with the resolution and signal-to-noise characteristics of EID data. Our hybrid reconstruction technique is based on an algebraic model of data fidelity which substitutes the EID data into the data fidelity term associated with the PCD reconstruction, resulting in a joint reconstruction problem. Within the split Bregman framework, these data fidelity constraints are minimized subject to additional constraints on spectral rank and on joint intensity-gradient sparsity measured between the reconstructions of the EID and PCD data. Following a derivation of the proposed technique, we apply it to the reconstruction of a digital phantom which contains realistic concentrations of iodine, barium, and calcium encountered in small-animal micro-CT. The results of this experiment suggest reliable separation and detection of iodine at concentrations ≥ 5 mg/ml and barium at concentrations ≥ 10 mg/ml in 2-mm features for EID and PCD data reconstructed with inherent spatial resolutions of 176 μm and 254 μm, respectively (point spread function, FWHM). Furthermore, hybrid reconstruction is demonstrated to enhance spatial resolution within material decomposition results and to improve low-contrast detectability by as much as 2.6 times relative to reconstruction with PCD data only. The parameters of the simulation experiment are based on an in vivo micro-CT experiment conducted in a mouse model of soft-tissue sarcoma. Material decomposition results produced from this in vivo data demonstrate the feasibility of distinguishing two K-edge contrast agents with a spectral

  18. Peripheral Defocus of the Monkey Crystalline Lens With Accommodation in a Lens Stretcher

    Science.gov (United States)

    Maceo Heilman, Bianca; Manns, Fabrice; Ruggeri, Marco; Ho, Arthur; Gonzalez, Alex; Rowaan, Cor; Bernal, Andres; Arrieta, Esdras; Parel, Jean-Marie

    2018-01-01

    Purpose To characterize the peripheral defocus of the monkey crystalline lens and its changes with accommodation. Methods Experiments were performed on 15 lenses from 11 cynomolgus monkey eyes (age: 3.8–12.4 years, postmortem time: 33.5 ± 15.3 hours). The tissue was mounted in a motorized lens stretcher to allow for measurements of the lens in the accommodated (unstretched) and unaccommodated (stretched) states. A custom-built combined laser ray tracing and optical coherence tomography system was used to measure the paraxial on-axis and off-axis lens power for delivery angles ranging from −20° to +20° (in air). For each delivery angle, peripheral defocus was quantified as the difference between paraxial off-axis and on-axis power. The peripheral defocus of the lens was compared in the unstretched and stretched states. Results On average, the paraxial on-axis lens power was 52.0 ± 3.4 D in the unstretched state and 32.5 ± 5.1 D in the stretched state. In both states, the lens power increased with increasing delivery angle. From 0° to +20°, the relative peripheral lens power increased by 10.7 ± 1.4 D in the unstretched state and 7.5 ± 1.6 D in the stretched state. The change in field curvature with accommodation was statistically significant (P lens has greater curvature or relative peripheral power. Conclusions The cynomolgus monkey lens has significant accommodation-dependent curvature of field, which suggests that the lens asserts a significant contribution to the peripheral optical performance of the eye that also varies with the state of accommodation.

  19. Optimal control of hybrid vehicles

    CERN Document Server

    Jager, Bram; Kessels, John

    2013-01-01

    Optimal Control of Hybrid Vehicles provides a description of power train control for hybrid vehicles. The background, environmental motivation and control challenges associated with hybrid vehicles are introduced. The text includes mathematical models for all relevant components in the hybrid power train. The power split problem in hybrid power trains is formally described and several numerical solutions detailed, including dynamic programming and a novel solution for state-constrained optimal control problems based on Pontryagin’s maximum principle.   Real-time-implementable strategies that can approximate the optimal solution closely are dealt with in depth. Several approaches are discussed and compared, including a state-of-the-art strategy which is adaptive for vehicle conditions like velocity and mass. Two case studies are included in the book: ·        a control strategy for a micro-hybrid power train; and ·        experimental results obtained with a real-time strategy implemented in...

  20. Sharing of secondary electrons by in-lens and out-lens detector in low-voltage scanning electron microscope equipped with immersion lens.

    Science.gov (United States)

    Kumagai, Kazuhiro; Sekiguchi, Takashi

    2009-03-01

    To understand secondary electron (SE) image formation with in-lens and out-lens detector in low-voltage scanning electron microscopy (LV-SEM), we have evaluated SE signals of an in-lens and an out-lens detector in LV-SEM. From the energy distribution spectra of SEs with various boosting voltages of the immersion lens system, we revealed that the electrostatic field of the immersion lens mainly collects electrons with energy lower than 40eV, acting as a low-pass filter. This effect is also observed as a contrast change in LV-SEM images taken by in-lens and out-lens detectors.

  1. Post-lens tear turbidity and visual quality after scleral lens wear.

    Science.gov (United States)

    Carracedo, Gonzalo; Serramito-Blanco, Maria; Martin-Gil, Alba; Wang, Zicheng; Rodriguez-Pomar, Candela; Pintor, Jesús

    2017-11-01

    The aim was to evaluate the turbidity and thickness of the post-lens tear layer and its effect on visual quality in patients with keratoconus after the beginning of lens wear and before lens removal at the end of eight hours. Twenty-six patients with keratoconus (aged 36.95 ± 8.95 years) participated voluntarily in the study. The sample was divided into two groups: patients with intrastromal corneal ring (ICRS group) and patients without ICRS (KC group). Distance visual acuity (VA), contrast sensitivity, pachymetry, post-lens tear layer height and post-lens tear layer turbidity (percentage area occupied and number of particles per mm 2 ) were evaluated with optical coherence tomography before and after wearing a scleral lens. A significant increase of turbidity was found in all groups assessed (p turbidity parameters with distance VA but no correlation between turbidity and post-lens tear layer thickness at the beginning was found (p > 0.05). A strong correlation in all groups between the post-lens tear layer at the beginning and differences of tear layer thickness between two measures was also found (p turbidity. © 2017 Optometry Australia.

  2. Effect of infusion bottle height on lens power after lens refilling with and without a plug

    NARCIS (Netherlands)

    Koopmans, SA; Terwee, T; Haitjema, HJ; Kooijman, AC; Barkhof, J

    2003-01-01

    Purpose: To evaluate the influence of intraoperative infusion bottle height on the power of refilled pig lenses. Setting: Research Laboratory, Pharmacia Intraocular Lens Manufacturing Plant, Groningen, The Netherlands. Methods: This study comprised 2 groups of pig eyes. In 1 group, the lens was

  3. Disassembly of the lens fiber cell nucleus to create a clear lens: the p27 descent

    Science.gov (United States)

    The eye lens is unique among tissues: it is transparent, does not form tumors, and the majority of its cells degrade their organelles, including their cell nuclei. A mystery for over a century, there has been considerable recent progress in elucidating mechanisms of lens fiber cell denucleation (LFC...

  4. MicroED data collection and processing

    Energy Technology Data Exchange (ETDEWEB)

    Hattne, Johan; Reyes, Francis E.; Nannenga, Brent L.; Shi, Dan; Cruz, M. Jason de la [Janelia Research Campus, Howard Hughes Medical Institute, Ashburn, VA 20147 (United States); Leslie, Andrew G. W. [Medical Research Council Laboratory of Molecular Biology, Cambridge (United Kingdom); Gonen, Tamir, E-mail: gonent@janelia.hhmi.org [Janelia Research Campus, Howard Hughes Medical Institute, Ashburn, VA 20147 (United States)

    2015-07-01

    The collection and processing of MicroED data are presented. MicroED, a method at the intersection of X-ray crystallography and electron cryo-microscopy, has rapidly progressed by exploiting advances in both fields and has already been successfully employed to determine the atomic structures of several proteins from sub-micron-sized, three-dimensional crystals. A major limiting factor in X-ray crystallography is the requirement for large and well ordered crystals. By permitting electron diffraction patterns to be collected from much smaller crystals, or even single well ordered domains of large crystals composed of several small mosaic blocks, MicroED has the potential to overcome the limiting size requirement and enable structural studies on difficult-to-crystallize samples. This communication details the steps for sample preparation, data collection and reduction necessary to obtain refined, high-resolution, three-dimensional models by MicroED, and presents some of its unique challenges.

  5. Hybrid composites

    CSIR Research Space (South Africa)

    Jacob John, Maya

    2009-04-01

    Full Text Available mixed short sisal/glass hybrid fibre reinforced low density polyethylene composites was investigated by Kalaprasad et al [25].Chemical surface modifications such as alkali, acetic anhydride, stearic acid, permanganate, maleic anhydride, silane...

  6. Nuclear magnetic resonance studies of lens transparency

    International Nuclear Information System (INIS)

    Beaulieu, C.F.

    1989-01-01

    Transparency of normal lens cytoplasm and loss of transparency in cataract were studied by nuclear magnetic resonance (NMR) methods. Phosphorus ( 31 P) NMR spectroscopy was used to measure the 31 P constituents and pH of calf lens cortical and nuclear homogenates and intact lenses as a function of time after lens enucleation and in opacification produced by calcium. Transparency was measured with laser spectroscopy. Despite complete loss of adenosine triphosphate (ATP) within 18 hrs of enucleation, the homogenates and lenses remained 100% transparent. Additions of calcium to ATP-depleted cortical homogenates produced opacification as well as concentration-dependent changes in inorganic phosphate, sugar phosphates, glycerol phosphorylcholine and pH. 1 H relaxation measurements of lens water at 200 MHz proton Larmor frequency studied temperature-dependent phase separation of lens nuclear homogenates. Preliminary measurements of T 1 and T 2 with non-equilibrium temperature changes showed a change in the slope of the temperature dependence of T 1 and T 2 at the phase separation temperature. Subsequent studies with equilibrium temperature changes showed no effect of phase separation on T 1 or T 2 , consistent with the phase separation being a low-energy process. 1 H nuclear magnetic relaxation dispersion (NMRD) studies (measurements of the magnetic field dependence of the water proton 1/T 1 relaxation rates) were performed on (1) calf lens nuclear and cortical homogenates (2) chicken lens homogenates, (3) native and heat-denatured egg white and (4) pure proteins including bovine γ-II crystallin bovine serum albumin (BSA) and myoglobin. The NMRD profiles of all samples exhibited decreases in 1/T 1 with increasing magnetic field

  7. Hybrid intermediaries

    OpenAIRE

    Cetorelli, Nicola

    2014-01-01

    I introduce the concept of hybrid intermediaries: financial conglomerates that control a multiplicity of entity types active in the "assembly line" process of modern financial intermediation, a system that has become known as shadow banking. The complex bank holding companies of today are the best example of hybrid intermediaries, but I argue that financial firms from the "nonbank" space can just as easily evolve into conglomerates with similar organizational structure, thus acquiring the cap...

  8. Properties of the cathode lens combined with a focusing magnetic/immersion-magnetic lens

    International Nuclear Information System (INIS)

    Konvalina, I.; Muellerova, I.

    2011-01-01

    The cathode lens is an electron optical element in an emission electron microscope accelerating electrons from the sample, which serves as a source for a beam of electrons. Special application consists in using the cathode lens first for retardation of an illuminating electron beam and then for acceleration of reflected as well as secondary electrons, made in the directly imaging low energy electron microscope or in its scanning version discussed here. In order to form a real image, the cathode lens has to be combined with a focusing magnetic lens or a focusing immersion-magnetic lens, as used for objective lenses of some commercial scanning electron microscopes. These two alternatives are compared with regards to their optical properties, in particular with respect to predicted aberration coefficients and the spot size, as well as the optimum angular aperture of the primary beam. The important role of the final aperture size on the image resolution is also presented.

  9. Photosensitized oxidation in the ocular lens: evidence for photosensitizers endogenous to the human lens

    International Nuclear Information System (INIS)

    Zigler, J.S. Jr.; Goosey, J.D.

    1981-01-01

    Numerous investigators have attempted to associate near UV light exposure with various changes which occur to lens crystallins during aging and cataractogenesis. Recently it was shown that in vitro singlet oxygen mediated oxidation of lens crystallins produces effects very similar to those documented for crystallins from old or cataractous lenses and it was suggested that near UV photodynamic effects may play a major role in vivo in aging in the human lens. It has now been shown that certain oxidation products of tryptophan which have been identified in human lens can act as near UV photosensitizers, producing singlet oxygen. The insoluble protein fraction from human cataracts was shown to have the capacity to act as a photosensitizer. An age-related increase in photosensitizing capacity was also demonstrated in the soluble crystallins from human lens. These findings are discussed with respect to development of pigmented nuclear cataracts. (author)

  10. Optical integration of Pancharatnam-Berry phase lens and dynamical phase lens

    International Nuclear Information System (INIS)

    Ke, Yougang; Liu, Yachao; Zhou, Junxiao; Liu, Yuanyuan; Luo, Hailu; Wen, Shuangchun

    2016-01-01

    In the optical system, most elements such as lens, prism, and optical fiber are made of silica glass. Therefore, integrating Pancharatnam-Berry phase elements into silica glass has potential applications in the optical system. In this paper, we take a lens, for example, which integrates a Pancharatnam-Berry phase lens into a conventional plano-convex lens. The spin states and positions of focal points can be modulated by controlling the polarization states of the incident beam. The proposed lens has a high transmission efficiency, and thereby acts as a simple and powerful tool to manipulate spin photons. Furthermore, the method can be conveniently extended to the optical fiber and laser cavity, and may provide a route to the design of the spin-photonic devices.

  11. Mixed Reality with HoloLens: Where Virtual Reality Meets Augmented Reality in the Operating Room.

    Science.gov (United States)

    Tepper, Oren M; Rudy, Hayeem L; Lefkowitz, Aaron; Weimer, Katie A; Marks, Shelby M; Stern, Carrie S; Garfein, Evan S

    2017-11-01

    Virtual reality and augmented reality devices have recently been described in the surgical literature. The authors have previously explored various iterations of these devices, and although they show promise, it has become clear that virtual reality and/or augmented reality devices alone do not adequately meet the demands of surgeons. The solution may lie in a hybrid technology known as mixed reality, which merges many virtual reality and augmented realty features. Microsoft's HoloLens, the first commercially available mixed reality device, provides surgeons intraoperative hands-free access to complex data, the real environment, and bidirectional communication. This report describes the use of HoloLens in the operating room to improve decision-making and surgical workflow. The pace of mixed reality-related technological development will undoubtedly be rapid in the coming years, and plastic surgeons are ideally suited to both lead and benefit from this advance.

  12. [Representation and mathematical analysis of human crystalline lens].

    Science.gov (United States)

    Tălu, Stefan; Giovanzana, Stefano; Tălu, Mihai

    2011-01-01

    The surface of human crystalline lens can be described and analyzed using mathematical models based on parametric representations, used in biomechanical studies and 3D solid modeling of the lens. The mathematical models used in lens biomechanics allow the study and the behavior of crystalline lens on variables and complex dynamic loads. Also, the lens biomechanics has the potential to improve the results in the development of intraocular lenses and cataract surgery. The paper presents the most representative mathematical models currently used for the modeling of human crystalline lens, both optically and biomechanically.

  13. Development of Powerhouse Using Fresnel lens

    Directory of Open Access Journals (Sweden)

    Al-Dohani Nawar Saif

    2018-01-01

    Full Text Available Solar energy is an alternative source of renewable energy. Sultanate of Oman government showed initiation on utilization of solar energy for domestic and industrial applications. Fresnel lens is one of the methods to collect maximum energy by gathering heat of the sun in the concentrated form (using solar collectors. Earlier research work discloses that Fresnel lens gave better result in terms of power output and produces lower heat loss as compared to linear –parabolic solar collectors. In this work, development of a proto Fresnel lens power house was made to generate electricity. The focused heat from Fresnel lens was used to heat the molten salt in a heat exchanger to produce the steam. The generated steam was used to rotate the steam engine coupled to a generator. In the current work, a maximum power of 30 W was produced. In addition, comparative study was carried out regarding solar salts and heat exchanger materials to understand the Fresnel powerhouse performance. Overall the present study gave valuable information regarding usage of Fresnel lens for electricity generation in Oman.

  14. A lazy way to design infrared lens

    Science.gov (United States)

    Qiu, RongSheng; Wu, JianDong; Chen, LongJiang; Yu, Kun; Pang, HaoJun; Hu, BaiZhen

    2017-08-01

    We designed a compact middle-wave infrared (MWIR) lens with a large focal length ratio (about 1.5:1), used in the 3.7 to 4.8 μm range. The lens is consisted of a compact front group and a re-imaging group. Thanks to the compact front group configuration, it is possible to install a filter wheel mechanism in such a tight space. The total track length of the lens is about 50mm, which includes a 2mm thick protective window and a cold shield of 12mm. The full field of view of the lens is about 3.6°, and F number is less than 1.6, the image circle is about 4.6mm in diameter. The design performance of the lens reaches diffraction limitation, and doesn't change a lot during a temperature range of -40°C +60°C. This essay proposed a stepwise design method of infrared optical system guided by the qualitative approach. The method fully utilize the powerful global optimization ability, with a little effort to write code snippet in optical design software, frees optical engineer from tedious calculation of the original structure.

  15. TESS Lens-Bezel Assembly Modal Testing

    Science.gov (United States)

    Dilworth, Brandon J.; Karlicek, Alexandra

    2017-01-01

    The Transiting Exoplanet Survey Satellite (TESS) program, led by the Kavli Institute for Astrophysics and Space Research at the Massachusetts Institute of Technology (MIT) will be the first-ever spaceborne all-sky transit survey. MIT Lincoln Laboratory is responsible for the cameras, including the lens assemblies, detector assemblies, lens hoods, and camera mounts. TESS is scheduled to be launched in August of 2017 with the primary goal to detect small planets with bright host starts in the solar neighborhood, so that detailed characterizations of the planets and their atmospheres can be performed. The TESS payload consists of four identical cameras and a data handling unit. Each camera consists of a lens assembly with seven optical elements and a detector assembly with four charge-coupled devices (CCDs) including their associated electronics. The optical prescription requires that several of the lenses are in close proximity to a neighboring element. A finite element model (FEM) was developed to estimate the relative deflections between each lens-bezel assembly under launch loads to predict that there are adequate clearances preventing the lenses from making contact. Modal tests using non-contact response measurements were conducted to experimentally estimate the modal parameters of the lens-bezel assembly, and used to validate the initial FEM assumptions. Key Words Non-contact measurements, modal analysis, model validation

  16. Micro club

    CERN Multimedia

    Micro club

    2014-01-01

    Opération NEMO   Pour finir en beauté les activités spéciales que le CMC a réalisé pendant cette année 2014, pour commémorer le 60ème anniversaire du CERN, et le 30ème du Micro Club, l’ Opération NEMO aura cette année un caractère très particulier. Nous allons proposer 6 fabricants de premier ordre qui offriront chacun deux ou trois produits à des prix exceptionnels. L’opération débute le lundi 17 novembre 2014. Elle se poursuivra  jusqu’au samedi 6 décembre inclus. Les délais de livraison seront de deux à trois semaines, selon les fabricants. Donc les commandes faites la dernière semaine, du 1 au 6 décembre, risquent d’arriver qu'au début du mois de janvier 2015. Liste de fabricants part...

  17. Micro club

    CERN Multimedia

    Micro Club

    2014-01-01

    Jeudi 18 septembre 2014 à 18h30 au Bât. 567 R-029 Le CERN MICRO CLUB organise un Atelier sur la sécurité informatique. La Cyber-sécurité : Ce qui se passe vraiment, comment ne pas en être victime ! Orateur : Sebastian Lopienski Adjoint au Computer Security Officer du Département IT. Sujet : Cet exposé vous présentera les modes de sécurité actuels et les problèmes touchants les applications logicielles des ordinateurs, les réseaux ainsi que leurs utilisateurs. Cela inclus des informations sur les nouveaux types de vulnérabilité, les vecteurs d'attaque récents et une vue d'ensemble sur le monde de la cyber-sécurité en 2014. Biographie : Sebastian Lopienski travaille au CERN depuis 2001. Il est actuellement adjoint au Computer Security Officer et s'occupe de la protection de...

  18. Terahertz lens made out of natural stone.

    Science.gov (United States)

    Han, Daehoon; Lee, Kanghee; Lim, Jongseok; Hong, Sei Sun; Kim, Young Kie; Ahn, Jaewook

    2013-12-20

    Terahertz (THz) time-domain spectroscopy probes the optical properties of naturally occurring solid aggregates of minerals, or stones, in the THz frequency range. Refractive index and extinction coefficient measurement reveals that most natural stones, including mudstone, sandstone, granite, tuff, gneiss, diorite, slate, marble, and dolomite, are fairly transparent for THz frequency waves. Dolomite in particular exhibits a nearly uniform refractive index of 2.7 over the broad frequency range from 0.1 to 1 THz. The high index of refraction allows flexibility in lens designing with a shorter accessible focal length or a thinner lens with a given focal length. Good agreement between the experiment and calculation for the THz beam profile confirms that dolomite has high homogeneity as a lens material, suggesting the possibility of using natural stones for THz optical elements.

  19. Catadioptric aberration correction in cathode lens microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tromp, R.M. [IBM T.J. Watson Research Center, PO Box 218, Yorktown Heights, NY 10598 (United States); Kamerlingh Onnes Laboratory, Leiden Institute of Physics, Niels Bohrweg 2, 2333 CA Leiden (Netherlands)

    2015-04-15

    In this paper I briefly review the use of electrostatic electron mirrors to correct the aberrations of the cathode lens objective lens in low energy electron microscope (LEEM) and photo electron emission microscope (PEEM) instruments. These catadioptric systems, combining electrostatic lens elements with a reflecting mirror, offer a compact solution, allowing simultaneous and independent correction of both spherical and chromatic aberrations. A comparison with catadioptric systems in light optics informs our understanding of the working principles behind aberration correction with electron mirrors, and may point the way to further improvements in the latter. With additional developments in detector technology, 1 nm spatial resolution in LEEM appears to be within reach. - Highlights: • The use of electron mirrors for aberration correction in LEEM/PEEM is reviewed. • A comparison is made with similar systems in light optics. • Conditions for 1 nm spatial resolution are discussed.

  20. Invited review article: the electrostatic plasma lens.

    Science.gov (United States)

    Goncharov, Alexey

    2013-02-01

    The fundamental principles, experimental results, and potential applications of the electrostatic plasma lens for focusing and manipulating high-current, energetic, heavy ion beams are reviewed. First described almost 50 years ago, this optical beam device provides space charge neutralization of the ion beam within the lens volume, and thus provides an effective and unique tool for focusing high current beams where a high degree of neutralization is essential to prevent beam blow-up. Short and long lenses have been explored, and a lens in which the magnetic field is provided by rare-earth permanent magnets has been demonstrated. Applications include the use of this kind of optical tool for laboratory ion beam manipulation, high dose ion implantation, heavy ion accelerator injection, in heavy ion fusion, and other high technology.

  1. Characterization of lens based photoacoustic imaging system

    Directory of Open Access Journals (Sweden)

    Kalloor Joseph Francis

    2017-12-01

    Full Text Available Some of the challenges in translating photoacoustic (PA imaging to clinical applications includes limited view of the target tissue, low signal to noise ratio and the high cost of developing real-time systems. Acoustic lens based PA imaging systems, also known as PA cameras are a potential alternative to conventional imaging systems in these scenarios. The 3D focusing action of lens enables real-time C-scan imaging with a 2D transducer array. In this paper, we model the underlying physics in a PA camera in the mathematical framework of an imaging system and derive a closed form expression for the point spread function (PSF. Experimental verification follows including the details on how to design and fabricate the lens inexpensively. The system PSF is evaluated over a 3D volume that can be imaged by this PA camera. Its utility is demonstrated by imaging phantom and an ex vivo human prostate tissue sample.

  2. Characterization of lens based photoacoustic imaging system.

    Science.gov (United States)

    Francis, Kalloor Joseph; Chinni, Bhargava; Channappayya, Sumohana S; Pachamuthu, Rajalakshmi; Dogra, Vikram S; Rao, Navalgund

    2017-12-01

    Some of the challenges in translating photoacoustic (PA) imaging to clinical applications includes limited view of the target tissue, low signal to noise ratio and the high cost of developing real-time systems. Acoustic lens based PA imaging systems, also known as PA cameras are a potential alternative to conventional imaging systems in these scenarios. The 3D focusing action of lens enables real-time C-scan imaging with a 2D transducer array. In this paper, we model the underlying physics in a PA camera in the mathematical framework of an imaging system and derive a closed form expression for the point spread function (PSF). Experimental verification follows including the details on how to design and fabricate the lens inexpensively. The system PSF is evaluated over a 3D volume that can be imaged by this PA camera. Its utility is demonstrated by imaging phantom and an ex vivo human prostate tissue sample.

  3. 3D printed helical antenna with lens

    KAUST Repository

    Farooqui, Muhammad Fahad

    2016-12-19

    The gain of an antenna can be enhanced through the integration of a lens, however this technique has traditionally been restricted to planar antennas due to fabrication limitations of standard manufacturing processes. Here, with a unique combination of 3D and 2D inkjet printing of dielectric and metallic inks respectively, we demonstrate a Fresnel lens that has been monolithically integrated to a non-planar antenna (helix) for the first time. Antenna measurements show that the integration of a Fresnel lens enhances the gain of a 2-turn helix by around 4.6 dB giving a peak gain of about 12.9 dBi at 8.8 GHz.

  4. Photonic crystal based polarization insensitive flat lens

    International Nuclear Information System (INIS)

    Turduev, M; Bor, E; Kurt, H

    2017-01-01

    The paper proposes a new design of an inhomogeneous artificially created photonic crystal lens structure consisting of annular dielectric rods to efficiently focus both transverse electric and transverse magnetic polarizations of light into the same focal point. The locations of each individual cell that contains the annular dielectric rods are determined according to a nonlinear distribution function. The inner and outer radii of the annular photonic dielectric rods are optimized with respect to the polarization insensitive frequency response of the transmission spectrum of the lens structure. The physical background of the polarization insensitive focusing mechanism is investigated in both spatial and frequency domains. Moreover, polarization independent wavefront transformation/focusing has been explored in detail by investigating the dispersion relation of the structure. Corresponding phase index distribution of the lens is attained for polarization insensitive normalized frequency range of a / λ   =  0.280 and a / λ   =  0.300, where a denotes the lattice constant of the designed structure and λ denotes the wavelength of the incident light. We show the wave transformation performance and focal point movement dynamics for both polarizations of the lens structure by specially adjusting the length of the structure. The 3D finite-difference time domain numerical analysis is also performed to verifiy that the proposed design is able to focus the wave regardless of polarization into approximately the same focal point (difference between focal distances of both polarizations stays below 0.25 λ ) with an operating bandwidth of 4.30% between 1476 nm and 1541 nm at telecom wavelengths. The main superiorities of the proposed lens structure are being all dielectric and compact, and having flat front and back surfaces, rendering the proposed lens design more practical in the photonic integration process in various applications such as optical switch

  5. Effect of infrared radiation on the lens

    Directory of Open Access Journals (Sweden)

    Aly Eman

    2011-01-01

    Full Text Available Background: Infrared (IR radiation is becoming more popular in industrial manufacturing processes and in many instruments used for diagnostic and therapeutic application to the human eye. Aim : The present study was designed to investigate the effect of IR radiation on rabbit′s crystalline lens and lens membrane. Materials and Methods: Fifteen New Zealand rabbits were used in the present work. The rabbits were classified into three groups; one of them served as control. The other two groups were exposed to IR radiation for 5 or 10 minutes. Animals from these two irradiated groups were subdivided into two subgroups; one of them was decapitated directly after IR exposure, while the other subgroup was decapitated 1 hour post exposure. IR was delivered from a General Electric Lamp model 250R 50/10, placed 20 cm from the rabbit and aimed at each eye. The activity of Na + -K + ATPase was measured in the lens membrane. Soluble lens proteins were extracted and the following measurements were carried out: estimation of total soluble protein, sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE and Fourier transform infrared (FTIR spectroscopy. For comparison between multiple groups, analysis of variance was used with significance level set at P < 0.001. Results: The results indicated a change in the molecular weight of different lens crystalline accompanied with changes in protein backbone structure. These changes increased for the groups exposed to IR for 10 minutes. Moreover, the activity of Na + -K + ATPase significantly decreased for all groups. Conclusions: The protein of eye lens is very sensitive to IR radiation which is hazardous and may lead to cataract.

  6. ANALYTICAL SOLUTIONS OF SINGULAR ISOTHERMAL QUADRUPOLE LENS

    International Nuclear Information System (INIS)

    Chu Zhe; Lin, W. P.; Yang Xiaofeng

    2013-01-01

    Using an analytical method, we study the singular isothermal quadrupole (SIQ) lens system, which is the simplest lens model that can produce four images. In this case, the radial mass distribution is in accord with the profile of the singular isothermal sphere lens, and the tangential distribution is given by adding a quadrupole on the monopole component. The basic properties of the SIQ lens have been studied in this Letter, including the deflection potential, deflection angle, magnification, critical curve, caustic, pseudo-caustic, and transition locus. Analytical solutions of the image positions and magnifications for the source on axes are derived. We find that naked cusps will appear when the relative intensity k of quadrupole to monopole is larger than 0.6. According to the magnification invariant theory of the SIQ lens, the sum of the signed magnifications of the four images should be equal to unity, as found by Dalal. However, if a source lies in the naked cusp, the summed magnification of the left three images is smaller than the invariant 1. With this simple lens system, we study the situations where a point source infinitely approaches a cusp or a fold. The sum of the magnifications of the cusp image triplet is usually not equal to 0, and it is usually positive for major cusps while negative for minor cusps. Similarly, the sum of magnifications of the fold image pair is usually not equal to 0 either. Nevertheless, the cusp and fold relations are still equal to 0 in that the sum values are divided by infinite absolute magnifications by definition.

  7. Intraocular Lens Calcification; a Clinicopathologic Report

    Directory of Open Access Journals (Sweden)

    Mozhgan Rezaei-Kanavi

    2009-04-01

    Full Text Available

    PURPOSE: To describe the clinical and pathological features of a case of hydrogel intraocular lens (IOL calcification. CASE REPORT: A 48-year-old man underwent explantation of a single-piece hydrophilic acrylic intraocular lens in his left eye because of decreased visual acuity and milky white opalescence of the IOL. The opacified lens was exchanged uneventfully with a hydrophobic acrylic IOL. Gross examination of the explanted IOL disclosed opacification of the optic and haptics. Full-thickness sections of the lens optic were stained with hematoxylin and eosin (H&E, von Kossa and Gram Tworts'. Microscopic examination of the sections revealed fine and diffuse basophilic granular deposits of variable size within the lens optic parallel to the lens curvature but separated from the surface by a moderately clear zone. The deposits were of high calcium content as evident by dark brown staining with von Kossa. Gram Tworts' staining disclosed no microorganisms. CONCLUSION: This report further contributes to the existing literature on hydrogel IOL calcification.

  8. Comparison of clear lens extraction and collamer lens implantation in high myopia

    Directory of Open Access Journals (Sweden)

    Ahmed M Emarah

    2010-05-01

    Full Text Available Ahmed M Emarah, Mostafa A El-Helw, Hazem M YassinCairo University, Cairo, EgyptAim: To compare the outcomes of clear lens extraction and collamer lens implantation in high myopia.Patients and methods: Myopic patients younger than 40 years old with more than 12 diopters of myopia or who were not fit for laser-assisted in situ keratomileusis were included. Group 1 comprised patients undergoing clear lens extraction and Group 2 patients received the Visian implantable collamer lens. Outcome and complications were evaluated.Results: Postoperative best corrected visual acuity was -0.61 ± 0.18 in Group 1 and 0.79 ± 0.16 in Group 2. In Group 1, 71.4% achieved a postoperative uncorrected visual acuity better than the preoperative best corrected visual acuity, while only 51.8% patients achieved this in Group 2. Intraocular pressure decreased by 12.55% in Group 1, and increased by 15.11% in Group 2. Corneal endothelial cell density decreased by 4.47% in Group 1 and decreased by 5.67% in Group 2. Posterior capsule opacification occurred in Group 1. In Group 2, lens opacification occurred in 11.11%, significant pigment dispersion in 3.7%, and pupillary block glaucoma in 3.7%.Conclusion: Clear lens extraction presents less of a financial load up front, and less likelihood of the need for a secondary intervention in the future. Clear lens extraction is a more viable solution in developing countries with limited financial resources.Keywords: clear lens extraction, implantable collamer lens, myopia

  9. Liquid lens: advances in adaptive optics

    Science.gov (United States)

    Casey, Shawn Patrick

    2010-12-01

    'Liquid lens' technologies promise significant advancements in machine vision and optical communications systems. Adaptations for machine vision, human vision correction, and optical communications are used to exemplify the versatile nature of this technology. Utilization of liquid lens elements allows the cost effective implementation of optical velocity measurement. The project consists of a custom image processor, camera, and interface. The images are passed into customized pattern recognition and optical character recognition algorithms. A single camera would be used for both speed detection and object recognition.

  10. Pulse transformer for the AA lithium lens

    CERN Multimedia

    CERN PhotoLab

    1980-01-01

    The antiprotons emanating from the target were initially focused by a magnetic horn. Later on, a Li-lens was used during operation for the SPS collider, until 1992. A Li-rod (130 mm long, 34 mm in diameter) constituted the secondary of a 1:23 pulse-transformer. The half-sine pulse rose to 1000 kA in 900 microsec. The angular acceptance was 95 mrad. In operation after 1992, for LEAR only, a more modest Li-lens was used (155 mm long, diameter 20 mm, 480 kA, risetime 240 microsec, angular acceptance 75 mrad).

  11. Herniation of the anterior lens capsule

    Directory of Open Access Journals (Sweden)

    Pereira Nolette

    2007-01-01

    Full Text Available Herniation of the anterior lens capsule is a rare abnormality in which the capsule bulges forward in the pupillary area. This herniation can be mistaken for an anterior lenticonus where both the capsule and the cortex bulge forward. The exact pathology behind this finding is still unclear. We report the clinical, ultrasound biomicroscopy (UBM and histopathological findings of a case of herniation of the anterior lens capsule. UBM helped to differentiate this entity from anterior lenticonus. Light microscopy revealed capsular splitting suggestive of capsular delamination and collection of fluid (aqueous in the area of herniation giving it a characteristic appearance.

  12. Immunochemical analyses of soluble lens proteins in some marine fishes

    Digital Repository Service at National Institute of Oceanography (India)

    Menezes, M.R.

    Soluble eye lens proteins of 10 fishes, belonging to the families Clupeidae, Hemirhamphidae, Lactaridae, Scombridae, Stromatidae, Psettodidae, Bothidae and Soleidae were studied by immunoelectrophoresis using the lens antiserum of Sardinella...

  13. Analysis of Light Gathering Abilities of Dynamically Solidified Micro-lenses, and Their Implementation to Improve Sensitivity of Fluorescent PCR Micro-detectors.

    Science.gov (United States)

    Wu, Jian; Guo, Wei; Wang, Chunyan; Yu, Kuanxin; Chen, Tao; Li, Yinghui

    2015-06-01

    Fluorescent polymerase chain reaction (PCR) is becoming the preferred method of quantitative analysis due to its high specificity and sensitivity. We propose to use a new kind of micro-lens, dynamically solidified with optic glue, to improve the sensitivity of fluorescent PCR micro-detector. We developed light ray track equations for these lenses and used them to calculate relative light intensity distribution curve for stimulation lenses and illumination point probability distribution curve for detection lenses. We manufactured dynamically solidified micro-lenses using optic glue NOA61, and measured their light gathering ability. Lenses with radius/thickness (R/H) ratio of 4 reached light focusing ratio of 3.85 (stimulation lens) and photon collection efficiency of 0.86 (detection lens). We then used dynamically solidified lenses in PCR fluorescence micro-detector and analyzed their effect on the detector sensitivity. We showed that the use of dynamically solidified micro-lenses with R/H = 4 resulted in over 4.4-fold increased sensitivity of the detector.

  14. Hybrid Filter Membrane

    Science.gov (United States)

    Laicer, Castro; Rasimick, Brian; Green, Zachary

    2012-01-01

    Cabin environmental control is an important issue for a successful Moon mission. Due to the unique environment of the Moon, lunar dust control is one of the main problems that significantly diminishes the air quality inside spacecraft cabins. Therefore, this innovation was motivated by NASA s need to minimize the negative health impact that air-suspended lunar dust particles have on astronauts in spacecraft cabins. It is based on fabrication of a hybrid filter comprising nanofiber nonwoven layers coated on porous polymer membranes with uniform cylindrical pores. This design results in a high-efficiency gas particulate filter with low pressure drop and the ability to be easily regenerated to restore filtration performance. A hybrid filter was developed consisting of a porous membrane with uniform, micron-sized, cylindrical pore channels coated with a thin nanofiber layer. Compared to conventional filter media such as a high-efficiency particulate air (HEPA) filter, this filter is designed to provide high particle efficiency, low pressure drop, and the ability to be regenerated. These membranes have well-defined micron-sized pores and can be used independently as air filters with discreet particle size cut-off, or coated with nanofiber layers for filtration of ultrafine nanoscale particles. The filter consists of a thin design intended to facilitate filter regeneration by localized air pulsing. The two main features of this invention are the concept of combining a micro-engineered straight-pore membrane with nanofibers. The micro-engineered straight pore membrane can be prepared with extremely high precision. Because the resulting membrane pores are straight and not tortuous like those found in conventional filters, the pressure drop across the filter is significantly reduced. The nanofiber layer is applied as a very thin coating to enhance filtration efficiency for fine nanoscale particles. Additionally, the thin nanofiber coating is designed to promote capture of

  15. Chapter 03: Correct use of a hand lens

    Science.gov (United States)

    Alex Wiedenhoeft

    2011-01-01

    A hand lens is a powerful tool for the identification of wood, but like all tools it must be used correctly to take full advantage of its powers. The hand lens has two main parts, a lens that magnifies the object of interest (generally we use 10X or 14X lenses in wood identification; a 14X lens is recommended for use with this manual) and a housing to hold and protect...

  16. 21 CFR 886.1405 - Ophthalmic trial lens set.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens set. 886.1405 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1405 Ophthalmic trial lens set. (a) Identification. An ophthalmic trial lens set is a device that is a set of lenses of various dioptric powers...

  17. 21 CFR 886.1420 - Ophthalmic lens gauge.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic lens gauge. 886.1420 Section 886.1420...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1420 Ophthalmic lens gauge. (a) Identification. An ophthalmic lens gauge is a calibrated device intended to manually measure the curvature of a...

  18. 21 CFR 886.1410 - Ophthalmic trial lens clip.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens clip. 886.1410 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1410 Ophthalmic trial lens clip. (a) Identification. An ophthalmic trial lens clip is a device intended to hold prisms, spheres, cylinders, or...

  19. 21 CFR 886.1380 - Diagnostic condensing lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Diagnostic condensing lens. 886.1380 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1380 Diagnostic condensing lens. (a) Identification. A diagnostic condensing lens is a device used in binocular indirect ophthalmoscopy (a procedure...

  20. 21 CFR 886.1415 - Ophthalmic trial lens frame.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens frame. 886.1415 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1415 Ophthalmic trial lens frame. (a) Identification. An opthalmic trial lens frame is a mechanical device intended to hold trial lenses for vision...

  1. In vivo study of lens regeneration in Rana cyanophlyctis under ...

    African Journals Online (AJOL)

    SAM

    2014-03-12

    Mar 12, 2014 ... enhanced the percentage lens regeneration not only in young tadpoles but also in froglets. Lens regeneration ability ... Influence of vitamin A and ascorbic acid on lens regeneration in young, mature tadpoles and froglets of the frog Rana cyanophlyctis. Group .... ingested by macrophages. Dorsal iris cells ...

  2. Vitrectorhexis and lens aspiration with posterior chamber intraocular lens implantation in spherophakia.

    Science.gov (United States)

    Al-Haddad, Christiane; Khatib, Lama

    2012-07-01

    We describe a technique that uses the vitrector to perform successful lens aspiration and posterior chamber intraocular lens (IOL) implantation in children with spherophakia and anterior lens subluxation. After an anterior chamber maintainer is placed, the ocutome is introduced through a limbal incision to perform a circular vitrectorhexis to avoid excessive manipulation of the unstable lens followed by gentle cortex aspiration. A foldable IOL is injected into the sulcus (3-piece IOL) or bag (1-piece IOL) if the capsule is sufficiently stable. Through a pars plana incision, the ocutome is then used to perform a posterior capsulotomy to prevent late posterior capsule opacification. In our patient, sulcus IOL placement was more stable than in-the-bag placement. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  3. Hybrid stars

    Indian Academy of Sciences (India)

    Hybrid stars. AsHOK GOYAL. Department of Physics and Astrophysics, University of Delhi, Delhi 110 007, India. Abstract. Recently there have been important developments in the determination of neutron ... number and the electric charge. ... available to the system to rearrange concentration of charges for a given fraction of.

  4. 3D printed helical antenna with lens

    KAUST Repository

    Farooqui, Muhammad Fahad; Shamim, Atif

    2016-01-01

    of 3D and 2D inkjet printing of dielectric and metallic inks respectively, we demonstrate a Fresnel lens that has been monolithically integrated to a non-planar antenna (helix) for the first time. Antenna measurements show that the integration of a

  5. Corneal ring infiltration in contact lens wearers

    Directory of Open Access Journals (Sweden)

    Seyed Ali Tabatabaei

    2017-01-01

    Full Text Available To report a case of atypical sterile ring infiltrates during wearing soft silicone hydrogel contact lens due to poor lens care. A 29-year-old woman presented with complaints of pain, redness, and morning discharge. She was wearing soft silicone hydrogel contact lens previously; her current symptoms began 1 week before presentation. On examination, best-corrected visual acuity was 20/40 in that eye. Slit-lamp examination revealed dense, ring-shaped infiltrate involving both the superficial and deep stromal layers with lucid interval to the limbus, edema of the epithelium, epithelial defect, and vascularization of the superior limbus. Cornea-specific in vivo laser confocal microscopy (Heidelberg Retina Tomograph 2 Rostock Cornea Module, HRT 2-RCM, Heidelberg Engineering GmbH, Dossenheim, Germany revealed Langerhans cells and no sign of Acanthamoeba or fungal features, using lid scraping and anti-inflammatory drops; her vision completely recovered. We reported an atypical case of a sterile corneal ring infiltrate associated with soft contact lens wearing; smear, culture, and confocal microscopy confirmed a sterile inflammatory reaction.

  6. Surgical treatment of hereditary lens subluxations.

    Science.gov (United States)

    Ozdek, Sengul; Sari, Ayca; Bilgihan, Kamil; Akata, Fikret; Hasanreisoglu, Berati

    2002-01-01

    To evaluate the effectiveness and results of pars plana vitreolensectomy approach with transscleral fixation of intraocular lens in hereditary lens subluxations. Fifteen eyes of 9 consecutive patients with a mean age of 12.8+/-6.2 years (6-26 years) with hereditary lens subluxation were operated on and the results were evaluated in a prospective study. Surgery was considered if best spectacle corrected visual acuity (BSCVA) was less than 20/70. All eyes underwent a 2-port pars plana vitreolensectomy and transscleral fixation of an intraocular lens (IOL). The mean follow-up period was 12.6+/-7.5 months (6-22 months). There was no major intraoperative complication. Preoperatively, 8 eyes (53.3%) had a BSCVA of counting fingers (CF) and 7 eyes (46.6%) had a BSCVA of 20/200 to 20/70. Postoperatively, 14 eyes (93.3%) had a BSCVA of 20/50 or better. None of the patients had IOL decentration or intraocular pressure (IOP) increase during the follow-up period. There was a macular hole formation in 1 eye postoperatively. The early results of pars plana vitreolensectomy with IOL implantation using scleral fixation technique had shown that it not only promises a rapid visual rehabilitation but it is also a relatively safe method. More serious complications, however, may occur in the long term.

  7. Lens Ray Diagrams with a Spreadsheet

    Science.gov (United States)

    González, Manuel I.

    2018-01-01

    Physicists create spreadsheets customarily to carry out numerical calculations and to display their results in a meaningful, nice-looking way. Spreadsheets can also be used to display a vivid geometrical model of a physical system. This statement is illustrated with an example taken from geometrical optics: images formed by a thin lens. A careful…

  8. Electronic states in a quantum lens

    International Nuclear Information System (INIS)

    Rodriguez, Arezky H.; Trallero-Giner, C.; Ulloa, S. E.; Marin-Antuna, J.

    2001-01-01

    We present a model to find analytically the electronic states in self-assembled quantum dots with a truncated spherical cap (''lens'') geometry. A conformal analytical image is designed to map the quantum dot boundary into a dot with semispherical shape. The Hamiltonian for a carrier confined in the quantum lens is correspondingly mapped into an equivalent operator and its eigenvalues and eigenfunctions for the corresponding Dirichlet problem are analyzed. A modified Rayleigh-Schro''dinger perturbation theory is presented to obtain analytical expressions for the energy levels and wave functions as a function of the spherical cap height b and radius a of the circular cross section. Calculations for a hard wall confinement potential are presented, and the effect of decreasing symmetry on the energy values and eigenfunctions of the lens-shape quantum dot is studied. As the degeneracies of a semicircular geometry are broken for b≠a, our perturbation approach allows tracking of the split states. Energy states and electronic wave functions with m=0 present the most pronounced influence on the reduction of the lens height. The method and expressions presented here can be straightforwardly extended to deal with more general Hamiltonians, including strains and valence-band coupling effects in Group III--V and Group II--VI self-assembled quantum dots

  9. Detection of viability of micro-algae cells by optofluidic hologram pattern.

    Science.gov (United States)

    Wang, Junsheng; Yu, Xiaomei; Wang, Yanjuan; Pan, Xinxiang; Li, Dongqing

    2018-03-01

    A rapid detection of micro-algae activity is critical for analysis of ship ballast water. A new method for detecting micro-algae activity based on lens-free optofluidic holographic imaging is presented in this paper. A compact lens-free optofluidic holographic imaging device was developed. This device is mainly composed of a light source, a small through-hole, a light propagation module, a microfluidic chip, and an image acquisition and processing module. The excited light from the light source passes through a small hole to reach the surface of the micro-algae cells in the microfluidic chip, and a holographic image is formed by the diffraction light of surface of micro-algae cells. The relation between the characteristics in the hologram pattern and the activity of micro-algae cells was investigated by using this device. The characteristics of the hologram pattern were extracted to represent the activity of micro-algae cells. To demonstrate the accuracy of the presented method and device, four species of micro-algae cells were employed as the test samples and the comparison experiments between the alive and dead cells of four species of micro-algae were conducted. The results show that the developed method and device can determine live/dead microalgae cells accurately.

  10. Changes in monkey crystalline lens spherical aberration during simulated accommodation in a lens stretcher.

    Science.gov (United States)

    Maceo Heilman, Bianca; Manns, Fabrice; de Castro, Alberto; Durkee, Heather; Arrieta, Esdras; Marcos, Susana; Parel, Jean-Marie

    2015-02-10

    The purpose of this study was to quantify accommodation-induced changes in the spherical aberration of cynomolgus monkey lenses. Twenty-four lenses from 20 cynomolgus monkeys (Macaca fascicularis; 4.4-16.0 years of age; postmortem time 13.5 ± 13.0 hours) were mounted in a lens stretcher. Lens spherical aberration was measured in the unstretched (accommodated) and stretched (relaxed) states with a laser ray tracing system that delivered 51 equally spaced parallel rays along 1 meridian of the lens over the central 6-mm optical zone. A camera mounted below the lens was used to measure the ray height at multiple positions along the optical axis. For each entrance ray, the change in ray height with axial position was fitted with a third-order polynomial. The effective paraxial focal length and Zernike spherical aberration coefficients corresponding to a 6-mm pupil diameter were extracted from the fitted values. The unstretched lens power decreased with age from 59.3 ± 4.0 diopters (D) for young lenses to 45.7 ± 3.1 D for older lenses. The unstretched lens shifted toward less negative spherical aberration with age, from -6.3 ± 0.7 μm for young lenses to -5.0 ± 0.5 μm for older lenses. The power and spherical aberration of lenses in the stretched state were independent of age, with values of 33.5 ± 3.4 D and -2.6 ± 0.5 μm, respectively. Spherical aberration is negative in cynomolgus monkey lenses and becomes more negative with accommodation. These results are in good agreement with the predicted values using computational ray tracing in a lens model with a reconstructed gradient refractive index. The spherical aberration of the unstretched lens becomes less negative with age. Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.

  11. Method for producing an isoplanatic aspheric monofocal intraocular lens, and resul ting lens

    OpenAIRE

    Barbero, Sergio; Marcos, Susana; Dorronsoro, Carlos; Montejo, Javier; Salazar Salegui, Pedro

    2010-01-01

    [EN] The invention can be used to obtain isoplanatic aspheric mono focal intraocular lenses in a viewing range of up to 25° (preferably up to 10°). The method comprises the following steps: l. mathematical defmition of an aphakic eye model; 2. mathematical definition of an intraocular lens model; 3. mathematical defmition of the implantation of the lens; 4. mathematical defmition of the merit function; 5. definition of the contour conditions; 6. defmition of a measurement for charact...

  12. Properties of the cathode lens combined with a focusing magnetic/immersion-magnetic lens

    Czech Academy of Sciences Publication Activity Database

    Konvalina, Ivo; Müllerová, Ilona

    2011-01-01

    Roč. 645, č. 1 (2011), s. 55-59 ISSN 0168-9002 R&D Projects: GA ČR GAP102/10/1410; GA AV ČR IAA100650902; GA MŠk ED0017/01/01 Institutional research plan: CEZ:AV0Z20650511 Keywords : cathode lens * compound objective lens * aberration coefficients * spot size * field calculations Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.207, year: 2011

  13. Preliminary Investigation of an Active PLZT Lens

    Science.gov (United States)

    Lightsey, W. D.; Peters, B. R.; Reardon, P. J.; Wong, J. K.

    2001-01-01

    The design, analysis and preliminary testing of a prototype Adjustable Focus Optical Correction Lens (AFOCL) is described. The AFOCL is an active optical component composed of solid state lead lanthanum-modified zirconate titanate (PLZT) ferroelectric ceramic with patterned indium tin oxide (ITO) transparent surface electrodes that modulate the refractive index of the PLZT to function as an electro-optic lens. The AFOCL was developed to perform optical re-alignment and wavefront correction to enhance the performance of Ultra-Lightweight Structures and Space Observatories (ULSSO). The AFOCL has potential application as an active optical component within a larger optical system. As such, information from a wavefront sensor would be processed to provide input to the AFOCL to drive the sensed wavefront to the desired shape and location. While offering variable and rapid focussing capability (controlled wavefront manipulation) similar to liquid crystal based spatial light modulators (SLM), the AFOCL offers some potential advantages because it is a solid-state, stationary, low-mass, rugged, and thin optical element that can produce wavefront quality comparable to the solid refractive lens it replaces. The AFOCL acts as a positive or negative lens by producing a parabolic phase-shift in the PLZT material through the application of a controlled voltage potential across the ITO electrodes. To demonstrate the technology, a 4 mm diameter lens was fabricated to produce 5-waves of optical power operating at 2.051 micrometer wavelength. Optical metrology was performed on the device to measure focal length, optical quality, and efficiency for a variety of test configurations. The data was analyzed and compared to theoretical data available from computer-based models of the AFOCL.

  14. Gram negative bacteria and contact lens induced acute red eye

    Directory of Open Access Journals (Sweden)

    Sankaridurg Padmaja

    1996-01-01

    Full Text Available Two patients using hydrogel contact lenses on a daily wear schedule slept overnight with the lenses and woke up with a Contact Lens Induced Acute Red Eye (CLARE. The contact lenses recovered aseptically at the time of the event grew significant colonies of Pseudomonas aeruginosa and Aeromonas hydrophila in patient A and Pseudomonas aeruginosa and Serratia liquefaciens from patient B. Similar organisams from the contact lenses were recovered from the lens case and lens care solutions of patient B. In both the patients the condition resolved on discontinuation of lens wear. Patient compliance as a requirement for successful contact lens wear is highlighted with the illustration of these cases.

  15. The influence of end of day silicone hydrogel daily disposable contact lens fit on ocular comfort, physiology and lens wettability.

    Science.gov (United States)

    Wolffsohn, James; Hall, Lee; Mroczkowska, Stephanie; Hunt, Olivia A; Bilkhu, Paramdeep; Drew, Tom; Sheppard, Amy

    2015-10-01

    To quantify the end-of-day silicone-hydrogel daily disposable contact lens fit and its influence of on ocular comfort, physiology and lens wettability. Thirty-nine subjects (22.1±3.5 years) were randomised to wear each of 3 silicone-hydrogel daily-disposable contact lenses (narafilcon A, delefilcon A and filcon II 3), bilaterally, for one week. Lens fit was assessed objectively using a digital video slit-lamp at 8, 12 and 16h after lens insertion. Hyperaemia, non-invasive tear break-up time, tear meniscus height and comfort were also evaluated at these timepoints, while corneal and conjunctival staining were assessed on lens removal. Lens fit assessments were not different between brands (P>0.05), with the exception of the movement at blink where narafilcon A was more mobile. Overall, lag reduced but push-up speed increased from 8 to 12h (P0.05). Movement-on-blink was unaffected by wear-time (F=0.403, P=0.670). A more mobile lens fit with one brand did not indicate that person would have a more mobile fit with another brand (r=-0.06 to 0.63). Lens fit was not correlated with comfort, ocular physiology or lens wettability (P>0.01). Among the lenses tested, objective lens fit changed between 8h and 12h of lens wear. The weak correlation in individual lens fit between brands indicates that fit is dependent on more than ocular shape. Consequently, substitution of a different lens brand with similar parameters will not necessarily provide comparable lens fit. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  16. Acid phosphatase and lipid peroxidation in human cataractous lens epithelium

    Directory of Open Access Journals (Sweden)

    Vasavada Abhay

    1993-01-01

    Full Text Available The anterior lens epithelial cells undergo a variety of degenerative and proliferative changes during cataract formation. Acid phosphatase is primarily responsible for tissue regeneration and tissue repair. The lipid hydroperoxides that are obtained by lipid peroxidation of polysaturated or unsaturated fatty acids bring about deterioration of biological membranes at cellular and tissue levels. Acid phosphatase and lipid peroxidation activities were studied on the lens epithelial cells of nuclear cataract, posterior subcapsular cataract, mature cataract, and mixed cataract. Of these, mature cataractous lens epithelium showed maximum activity for acid phosphatase (516.83 moles of p-nitrophenol released/g lens epithelium and maximum levels of lipid peroxidation (86.29 O.D./min/g lens epithelium. In contrast, mixed cataractous lens epithelium showed minimum activity of acid phosphatase (222.61 moles of p-nitrophenol released/g lens epithelium and minimum levels of lipid peroxidation (54.23 O.D./min/g lens epithelium. From our study, we correlated the maximum activity of acid phosphatase in mature cataractous lens epithelium with the increased areas of superimposed cells associated with the formation of mature cataract. Likewise, the maximum levels of lipid peroxidation in mature cataractous lens epithelium was correlated with increased permeability of the plasma membrane. Conversely, the minimum levels of lipid peroxidation in mixed cataractous lens epithelium makes us presume that factors other than lipid peroxidation may also account for the formation of mixed type of cataract.

  17. The partial coherence modulation transfer function in testing lithography lens

    Science.gov (United States)

    Huang, Jiun-Woei

    2018-03-01

    Due to the lithography demanding high performance in projection of semiconductor mask to wafer, the lens has to be almost free in spherical and coma aberration, thus, in situ optical testing for diagnosis of lens performance has to be established to verify the performance and to provide the suggesting for further improvement of the lens, before the lens has been build and integrated with light source. The measurement of modulation transfer function of critical dimension (CD) is main performance parameter to evaluate the line width of semiconductor platform fabricating ability for the smallest line width of producing tiny integrated circuits. Although the modulation transfer function (MTF) has been popularly used to evaluation the optical system, but in lithography, the contrast of each line-pair is in one dimension or two dimensions, analytically, while the lens stand along in the test bench integrated with the light source coherent or near coherent for the small dimension near the optical diffraction limit, the MTF is not only contributed by the lens, also by illumination of platform. In the study, the partial coherence modulation transfer function (PCMTF) for testing a lithography lens is suggested by measuring MTF in the high spatial frequency of in situ lithography lens, blended with the illumination of partial and in coherent light source. PCMTF can be one of measurement to evaluate the imperfect lens of lithography lens for further improvement in lens performance.

  18. Oxygen transport through soft contact lens and cornea: Lens characterization and metabolic modeling

    Science.gov (United States)

    Chhabra, Mahendra

    The human cornea requires oxygen to sustain metabolic processes critical for its normal functioning. Any restriction to corneal oxygen supply from the external environment (e.g., by wearing a low oxygen-permeability contact lens) can lead to hypoxia, which may cause corneal edema (swelling), limbal hyperemia, neovascularization, and corneal acidosis. The need for adequate oxygen to the cornea is a major driving force for research and development of hypertransmissible soft contact lenses (SCLs). Currently, there is no standard technique for measuring oxygen permeability (Dk) of hypertransmissible silicone-hydrogel SCLs. In this work, an electrochemistry-based polarographic apparatus was designed, built, and operated to measure oxygen permeability in hypertransmissible SCLs. Unlike conventional methods where a range of lens thickness is needed for determining oxygen permeabilities of SCLs, this apparatus requires only a single lens thickness. The single-lens permeameter provides a reliable, efficient, and economic tool for measuring oxygen permeabilities of commercial hypertransmissible SCLs. The single-lens permeameter measures not only the product Dk, but, following modification, it measures separately diffusivity, D, and solubility, k, of oxygen in hypertransmissible SCLs. These properties are critical for designing better lens materials that ensure sufficient oxygen supply to the cornea. Metabolism of oxygen in the cornea is influenced by contact-lens-induced hypoxia, diseases such as diabetes, surgery, and drug treatment, Thus, estimation of the in-vivo corneal oxygen consumption rate is essential for gauging adequate oxygen supply to the cornea. Therefore, we have developed an unsteady-state reactive-diffusion model for the cornea-contact-lens system to determine in-vivo human corneal oxygen-consumption rate. Finally, a metabolic model was developed to determine the relation between contact-lens oxygen transmissibility (Dk/L) and corneal oxygen deficiency. A

  19. Micro robot bible

    International Nuclear Information System (INIS)

    Yoon, Jin Yeong

    2000-08-01

    This book deals with micro robot, which tells of summary of robots like entertainment robots and definition of robots, introduction of micro mouse about history, composition and rules, summary of micro controller with its history, appearance and composition, introduction of stepping motor about types, structure, basic characteristics, and driving ways, summary of sensor section, power, understanding of 80C196KC micro controller, basic driving program searching a maze algorithm, smooth turn and making of tracer line.

  20. Micro intelligence robot

    International Nuclear Information System (INIS)

    Jeon, Yon Ho

    1991-07-01

    This book gives descriptions of micro robot about conception of robots and micro robot, match rules of conference of micro robots, search methods of mazes, and future and prospect of robots. It also explains making and design of 8 beat robot like making technique, software, sensor board circuit, and stepping motor catalog, speedy 3, Mr. Black and Mr. White, making and design of 16 beat robot, such as micro robot artist, Jerry 2 and magic art of shortening distances algorithm of robot simulation.

  1. Micro robot bible

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jin Yeong

    2000-08-15

    This book deals with micro robot, which tells of summary of robots like entertainment robots and definition of robots, introduction of micro mouse about history, composition and rules, summary of micro controller with its history, appearance and composition, introduction of stepping motor about types, structure, basic characteristics, and driving ways, summary of sensor section, power, understanding of 80C196KC micro controller, basic driving program searching a maze algorithm, smooth turn and making of tracer line.

  2. Optimized computational imaging methods for small-target sensing in lens-free holographic microscopy

    Science.gov (United States)

    Xiong, Zhen; Engle, Isaiah; Garan, Jacob; Melzer, Jeffrey E.; McLeod, Euan

    2018-02-01

    Lens-free holographic microscopy is a promising diagnostic approach because it is cost-effective, compact, and suitable for point-of-care applications, while providing high resolution together with an ultra-large field-of-view. It has been applied to biomedical sensing, where larger targets like eukaryotic cells, bacteria, or viruses can be directly imaged without labels, and smaller targets like proteins or DNA strands can be detected via scattering labels like micro- or nano-spheres. Automated image processing routines can count objects and infer target concentrations. In these sensing applications, sensitivity and specificity are critically affected by image resolution and signal-to-noise ratio (SNR). Pixel super-resolution approaches have been shown to boost resolution and SNR by synthesizing a high-resolution image from multiple, partially redundant, low-resolution images. However, there are several computational methods that can be used to synthesize the high-resolution image, and previously, it has been unclear which methods work best for the particular case of small-particle sensing. Here, we quantify the SNR achieved in small-particle sensing using regularized gradient-descent optimization method, where the regularization is based on cardinal-neighbor differences, Bayer-pattern noise reduction, or sparsity in the image. In particular, we find that gradient-descent with sparsity-based regularization works best for small-particle sensing. These computational approaches were evaluated on images acquired using a lens-free microscope that we assembled from an off-the-shelf LED array and color image sensor. Compared to other lens-free imaging systems, our hardware integration, calibration, and sample preparation are particularly simple. We believe our results will help to enable the best performance in lens-free holographic sensing.

  3. Scleral lens use in dry eye syndrome.

    Science.gov (United States)

    Bavinger, J Clay; DeLoss, Karen; Mian, Shahzad I

    2015-07-01

    Dry eye syndrome can be difficult to manage in severe or refractory cases. In patients in whom traditional treatments have limited efficacy, alternative treatments may be considered for dry eye syndrome, including scleral lenses. The present review summarizes the evidence regarding scleral lens use in dry eye syndrome. Scleral lenses have become a viable option for severe dry eye syndrome, and have been shown to be efficacious and well tolerated, with most reports citing improved visual acuity and relief of symptoms. Currently, there are 18 manufacturers of scleral lenses, although published reports on scleral lenses primarily focus on the BostonSight PROSE and the Jupiter Lens. Scleral lenses are efficacious and well tolerated for use in severe dry eye syndrome. Further research is needed to compare different sizes and types of lenses, and to standardize outcome measures.

  4. Gravitational Lens Time Delays Using Polarization Monitoring

    Directory of Open Access Journals (Sweden)

    Andrew Biggs

    2017-11-01

    Full Text Available Gravitational lens time delays provide a means of measuring the expansion of the Universe at high redshift (and therefore in the ‘Hubble flow’ that is independent of local calibrations. It was hoped that many of the radio lenses found in the JVAS/CLASS survey would yield time delays as these were selected to have flat spectra and are dominated by multiple compact components. However, despite extensive monitoring with the Very Large Array (VLA, time delays have only been measured for three of these systems (out of 22. We have begun a programme to reanalyse the existing VLA monitoring data with the goal of producing light curves in polarized flux and polarization position angle, either to improve delay measurements or to find delays for new sources. Here, we present preliminary results on the lens system B1600+434 which demonstrate the presence of correlated and substantial polarization variability in each image.

  5. A Tribute to Dr. Willy Lens

    Directory of Open Access Journals (Sweden)

    Maarten Vansteenkiste

    2016-07-01

    Full Text Available Dr. Willy Lens, born on December 10th, 1943, passed away on August 29th, 2014. With his passing, the motivation community has lost a seminal member, a mentor, and a friend. Dr. Lens – a Fellow of the Association for Psychological Science and Founding Fellow of the American Educational Research Association – made fundamental contributions to the study of motivation both through his own work and through his caring and thoughtful mentorship of a large community of scholars. With this tribute, we want to honor Dr. Willy Lens’ significance to psychology and education as well as his positive influence, both personally and professionally, on the lives of dozens of scholars. With his contagious enthusiasm and caring mentorship, Willy was an example for our academic community and with this tribute we express our gratitude for the privilege to have collaborated with him.

  6. Hyperbolic metamaterial lens with hydrodynamic nonlocal response.

    Science.gov (United States)

    Yan, Wei; Mortensen, N Asger; Wubs, Martijn

    2013-06-17

    We investigate the effects of hydrodynamic nonlocal response in hyperbolic metamaterials (HMMs), focusing on the experimentally realizable parameter regime where unit cells are much smaller than an optical wavelength but much larger than the wavelengths of the longitudinal pressure waves of the free-electron plasma in the metal constituents. We derive the nonlocal corrections to the effective material parameters analytically, and illustrate the noticeable nonlocal effects on the dispersion curves numerically. As an application, we find that the focusing characteristics of a HMM lens in the local-response approximation and in the hydrodynamic Drude model can differ considerably. In particular, the optimal frequency for imaging in the nonlocal theory is blueshifted with respect to that in the local theory. Thus, to detect whether nonlocal response is at work in a hyperbolic metamaterial, we propose to measure the near-field distribution of a hyperbolic metamaterial lens.

  7. Dose limits to the eye lens

    International Nuclear Information System (INIS)

    Sion, N.

    2016-01-01

    Protecting the human body from the effects of ionizing radiation is essential to forestall stochastic effects and require placing limits on the effective dose. Dose limits on specific organs are also necessary to reduce the deterministic effects and tissue reactions. The standard for radiation protection was ISO 15382 (2002) which mainly dealt with beta radiation for nuclear power plant workers. Clearly an update is required to allow for new technology and the proliferative use of radiation in medical practices. There is a need for more explicit radiation monitoring to operators and staff. ICRP118 (International Commission on Radiological Protection), Ref. 1, evolved their recommendations to include eye lens doses as a follow on to their publication 103 and to focus on radiation exposures. It provides updated estimates of 'practical' threshold doses for tissue injury at the level of 1% incidence. This paper discusses the current status and the recommendation for a drastic reduction of the dose limit to the eye lens. (author)

  8. PV-hybrid and mini-grid

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    Within the 5th European PV-hybrid and mini-grid conference 29th and 30th April, 2010 in Tarragona (Spain) the following lectures were held: (1) Overview of IEA PVPS Task 11 PV-hybrid systems within mini grids; (2) Photovoltaic revolution for deployment in developing countries; (3) Legal and financial conditions for the sustainable operation of mini-grids; (4) EU instruments to promote renewable energies in developing countries; (5) PV hybridization of diesel electricity generators: Conditions of profitability and examples in differential power and storage size ranges; (6) Education suit of designing PV hybrid systems; (7) Sustainable renewable energy projects for intelligent rural electrification in Laos, Cambodia and Vietnam; (8) Techno-economic feasibility of energy supply of remote villages in Palestine by PV systems, diesel generators and electric grid (Case studies: Emnazeil and Atouf villages); (9) Technical, economical and sustainability considerations of a solar PV mini grid as a tool for rural electrification in Uganda; (10) Can we rate inverters for rural electrification on the basis of energy efficiency?; (11) Test procedures for MPPT charge controllers characterization; (12) Energy storage for mini-grid stabilization; (13) Redox flow batteries - Already an alternative storage solution for hybrid PV mini-grids?; (14) Control methods for PV hybrid mini-grids; (15) Partial AC-coupling in mini-grids; (15) Normative issues of small wind turbines in PV hybrid systems; (16) Communication solutions for PV hybrid systems; (17) Towards flexible control and communication of mini-grids; (18) PV/methanol fuel cell hybrid system for powering a highway security variable message board; (19) Polygeneration smartgrids: A solution for the supply of electricity, potable water and hydrogen as fuel for transportation in remote Areas; (20) Implementation of the Bronsbergen micro grid using FACDS; (21) A revisited approach for the design of PV wind hybrid systems; (22

  9. Micro rapid prototyping system for micro components

    International Nuclear Information System (INIS)

    Li Xiaochun; Choi Hongseok; Yang Yong

    2002-01-01

    Similarities between silicon-based micro-electro-mechanical systems (MEMS) and Shape Deposition Manufacturing (SDM) processes are obvious: both integrate additive and subtractive processes and use part and sacrificial materials to obtain functional structures. These MEMS techniques are two-dimensional (2-D) processes for a limited number of materials while SDM enables the building of parts that have traditionally been impossible to fabricate because of their complex shapes or of their variety in materials. This work presents initial results on the development of a micro rapid prototyping system that adapts SDM methodology to micro-fabrication. This system is designed to incorporate microdeposition and laser micromachining. In the hope of obtaining a precise microdeposition, an ultrasonic-based micro powder-feeding mechanism was developed in order to form thin patterns of dry powders that can be cladded or sintered onto a substrate by a micro-sized laser beam. Furthermore, experimental results on laser micromachining using a laser beam with a wavelength of 355 nm are also presented. After further improvement, the developed micro manufacturing system could take computer-aided design (CAD) output to reproduce 3-D heterogeneous micro-components from a wide selection of materials

  10. The Multi-Lens Array Architecture

    Science.gov (United States)

    2007-02-26

    slowly with respect to f, numerical integration using Simpson’s 1/3 Rule is a convenient method to evaluate Eq. 11. It can be shown the result can...quality of the paper. The author also has had stimulating discussions with Mr. David Curtis, Dr. Boris Tomasic and Dr. Peter Franchi . 24...REFERENCES [1] W. Rotman, P. Franchi , “Cylindrical Microwave Lens Antenna for Wideband Scanning Application”, Antennas and Prop. Int. Symposium, vol. 18

  11. Performance of a Be Refractive Lens

    International Nuclear Information System (INIS)

    Smither, R.K.; Khounsary, A.M.; Mancini, D.C.; Saleem, K. Abu

    2004-01-01

    The performance of a beryllium compound refractive lens (CRL) was tested in the energy range of 11.5 to 8.0 keV. The beryllium refractive lens consists of 50 aligned, 1-mm-diameter, hollow spheres in a solid block of beryllium, 30 mm x 20 mm x 55 mm. The minimum web between each hollow sphere was 0.10 mm. The measured focal length of the lens for x-rays close to the axis of the beam was 147.7 cm +/- 2.0 cm at 10 keV and 120.2 +/- 2.0 cm at 9.1 keV. These values agree well with the theoretical values of 146.6 cm and 121.4 cm, respectively. The diameter of the best focus obtained at 10 keV was 35 μm horizontal and 45 μm vertical. For the modified version of the lens used in the 9.1 keV experiment these values were 25 μm horizontal and 35 μm vertical. The x-ray beam cross section for the 10 keV and the 9.1 keV experiments were 0.50 mm x 0.50 mm and 0.30 mm x 0.30 mm, respectively. The enhancement of the flux (photons per sq. mm) was 50:1 at 10 keV and 80:1 in the 9.1 keV experiment

  12. LENS spectroscopy of low energy solar neutrinos

    CERN Document Server

    Schönert, S

    2001-01-01

    The LENS experiments will measure energy resolved sub-MeV solar electron-neutrinos ( nu /sub e/) in real time via inverse beta - transition populating an isomeric state in the daughter nuclei. The subsequent de-excitation provides a delayed coincidence tag which discriminates against background. A liquid scintillation detector loaded with 20 t of Yb would yield an event rate of 190 pp- and 175 /sup 7/Be neutrinos per year. Essential information on neutrino mixing and masses can be derived.

  13. THE BOSS EMISSION-LINE LENS SURVEY. IV. SMOOTH LENS MODELS FOR THE BELLS GALLERY SAMPLE

    Energy Technology Data Exchange (ETDEWEB)

    Shu, Yiping [National Astronomical Observatories, Chinese Academy of Sciences, 20A Datun Road, Chaoyang District, Beijing 100012 (China); Bolton, Adam S.; Montero-Dorta, Antonio D.; Cornachione, Matthew A.; Zheng, Zheng; Brownstein, Joel R. [Department of Physics and Astronomy, University of Utah, 115 South 1400 East, Salt Lake City, UT 84112 (United States); Mao, Shude [Physics Department and Tsinghua Centre for Astrophysics, Tsinghua University, Beijing 100084 (China); Kochanek, Christopher S. [Department of Astronomy and Center for Cosmology and Astroparticle Physics, Ohio State University, Columbus, OH 43210 (United States); Pérez-Fournon, Ismael; Marques-Chaves, Rui [Instituto de Astrofísica de Canarias, C/Vía Láctea, s/n, E-38205 San Cristóbal de La Laguna, Tenerife (Spain); Oguri, Masamune [Research Center for the Early Universe, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Ménard, Brice, E-mail: yiping.shu@nao.cas.cn [Department of Physics and Astronomy, Johns Hopkins University, Baltimore, MD 21218 (United States)

    2016-12-20

    We present Hubble Space Telescope F606W-band imaging observations of 21 galaxy-Ly α emitter lens candidates in the Baryon Oscillation Spectroscopic Survey Emission-Line Lens Survey (BELLS) for the GALaxy-Ly α EmitteR sYstems (BELLS GALLERY) survey. Seventeen systems are confirmed to be definite lenses with unambiguous evidence of multiple imaging. The lenses are primarily massive early-type galaxies (ETGs) at redshifts of approximately 0.55, while the lensed sources are Ly α emitters (LAEs) at redshifts from two to three. Although most of the lens systems are well fit by smooth lens models consisting of singular isothermal ellipsoids in an external shear field, a thorough exploration of dark substructures in the lens galaxies is required. The Einstein radii of the BELLS GALLERY lenses are, on average, 60% larger than those of the BELLS lenses because of the much higher source redshifts. This will allow for a detailed investigation of the radius evolution of the mass profile in ETGs. With the aid of the average ∼13× lensing magnification, the LAEs are frequently resolved into individual star-forming knots with a wide range of properties. They have characteristic sizes from less than 100 pc to several kiloparsecs, rest-frame far-UV apparent AB magnitudes from 29.6 to 24.2, and typical projected separations of 500 pc to 2 kpc.

  14. [Congenital lens subluxation: visual acuity outcomes and intraocular lens postoperative position].

    Science.gov (United States)

    Arraes, Caroline; Endriss, Daniela; Lobato, Francisco; Arraes, João; Ventura, Marcelo

    2010-01-01

    To evaluate the visual acuity outcomes and to investigate the intraocular lens (IOL) and endocapsular ring positions with ultrasound biomicroscopy in 17 eyes of 10 patients with congenital lens subluxation who underwent the same surgical technique, by the same surgeon. The study was performed in the ''Hospital de Olhos de Pernambuco'' and ''Fundação Altino Ventura''. The surgical technique consisted of phacoaspiration with implant of endocapsular ring and intraocular lens with one loop haptic amputated. The age varied from 7 to 22 years. Data on visual acuity (VA) before and after surgery, surgery follow-up period, and complications were analyzed. All patients underwent ultrasound biomicroscopy. The mean follow-up period was 2.8 years. There was a VA improvement in 17 (100%) eyes: in 12 eyes (70.6%) the visual acuity was better than 20/40; 4 (23.5%) ranged from 20/40 to 20/100, and 1 (5.9%) had visual acuity worse than 20/100, however better than the preoperative visual acuity. The posterior capsular opacification occurred in 10 eyes (58.9%). Ultrasound biomicroscopy showed that all IOL were partially decentralized, however without surpassing the pupil border limit. Endocapsular ring position was correct and there was a good capsular support in all cases. The evaluated surgical treatment provided good intraocular lens and endocapsular ring position, with VA improvement Thus, this technique is a viable, effective and safe option for the visual rehabilitation of patients with congenital lens subluxation.

  15. Thermal lens measurements in the cornea.

    Science.gov (United States)

    Venkatesh, S; Guthrie, S; Cruickshank, F R; Bailey, R T; Foulds, W S; Lee, W R

    1985-02-01

    Q-switched pulses from a neodymium/YAG (yttrium-aluminium-garnet) laser were passed through corneal discs taken from the enucleated eyes of three baboons and four rabbits. The time course of heat dissipation following absorption of laser energy by the tissue was studied with the use of a second continuous wave laser beam acting as a probe. It was found that the absorption of each neodymium/YAG pulse created a transient divergent lens within the cornea as theoretical considerations predicted. The relaxation time that characterised the decay of this thermal lens for a 1/e laser beam diameter of 2.0 mm was found to be 2.3 +/- 0.1 s (mean +/- standard error for 12 separate groups of measurements). Our results show that Q-switched laser pulses passing through apparently unaffected transparent tissues can induce thermal lens effects which persist for several seconds. The optical transfer of each pulse in a stream will be identical only if enough time is left between pulses for the tissues to return to their initial state. Therefore, when such laser pulses sharply focused to perform high precision intraocular surgery are used, thermal lensing in the transparent ocular media must limit the rate at which pulses can be usefully delivered.

  16. Radiation dose to the eye lens

    DEFF Research Database (Denmark)

    Baun, Christina; Falch Braas, Kirsten; D. Nielsen, Kamilla

    2015-01-01

    Radiation Dose to the Eye Lens: Does Positioning Really Matter? C. Baun1, K. Falch1, K.D. Nielsen2, S. Shanmuganathan1, O. Gerke1, P.F. Høilund-Carlsen1 1Department of Nuclear Medicine, Odense University Hospital, Odense C, Denmark. 2University College Lillebaelt, Odense, Denmark. Aim: The scan...... field in oncology patients undergoing eyes-to-thighs PET/CT must always include the base of the scull according to department guidelines. The eye lens is sensitive to radiation exposure and if possible it should be avoided to scan the eye. If the patient’s head is kipped backwards during the scan one...... might avoid including the eye in the CT scan without losing sufficient visualization of the scull base. The aim of this study was to evaluate the possibility of decreasing the radiation dose to the eye lens, simply by changing the head position, when doing the PET/CT scan from the base of the scull...

  17. Metasurface axicon lens design at visible wavelengths

    Science.gov (United States)

    Alyammahi, Saleimah; Zhan, Qiwen

    2017-08-01

    The emerging field of metasurfaces is promising to realize novel optical devices with miniaturized flat format and added functionalities. Metasurfaces have been demonstrated to exhibit full control of amplitude, phase and polarization of electromagnetic waves. Using the metasurface, the wavefront of light can be manipulated permitting new functionalities such as focusing and steering of the beams and imaging. One optical component which can be designed using metasurfaces is the axicon. Axicons are conical lenses used to convert Gaussian beams into nondiffraction Bessel beams. These unique devices are utilized in different applications ranging from optical trapping and manipulation, medical imaging, and surgery. In this work, we study axicon lens design comprising of planar metasurfaces which generate non-diffracting Bessel beams at visible wavelengths. Dielectric metasurfaces have been used to achieve high efficiency and low optical loss. We measured the spot size of the resulted beams at different planes to demonstrate the non-diffraction properties of the resulted beams. We also investigated how the spot size is influenced by the axicon aperture. Furthermore, we examined the achromatic properties of the designed axicon. Comparing with the conventional lens, the metasurface axicon lens design enables the creation of flat optical device with wide range of depth of focus along its optical axis.

  18. Evaluation of lens dose in medulloblastoma radiotherapy

    International Nuclear Information System (INIS)

    Oliveira, F.L.; Vilela, E.C.; Sousa, S.A; Lima, F.F. de

    2007-01-01

    The improvement of the applied radiotherapy techniques in the cranial-spinal therapy, which is used in the cases of medulloblastoma, aims the reduction of the risks of future damages in enclosed critical agencies in the irradiation fields. This work aims to evaluate the lens doses due two common techniques used in medulloblastoma radiotherapy. For this, thermoluminescent dosimeters, previously calibrated, were located in an anthropomorphic phantom (ALDERSON - RANDON Laboratory), in the tumor and lens positions. The employed techniques were as following: (1) angled fields technique and (2) half-beam block technique. The phantom was irradiated five times in each technique with two lateral opposed fields in the brain with a total prescribed dose of 1.5 Gy, followed of two posterior spinal fields with the same prescribed dose, using a 6MV accelerator. The results showed that the doses in the first technique were 0.10 +- 0,04 Gy and, in second one, 0.09 +- 0,02 Gy. It was observed that, independent of the employed technique, the lens doses practically are the same. (author)

  19. Compound refractive X-ray lens

    International Nuclear Information System (INIS)

    Nygren, D.R.; Cahn, R.; Cederstrom, B.; Danielsson, M.; Vestlund, J.

    2000-01-01

    An apparatus and method are disclosed for focusing X-rays. In one embodiment, his invention is a commercial-grade compound refractive X-ray lens. The commercial-grade compound refractive X-ray lens includes a volume of low-Z material. The volume of low-Z material has a first surface which is adapted to receive X-rays of commercially-applicable power emitted from a commercial-grade X-ray source. The volume of low-Z material also has a second surface from which emerge the X-rays of commercially-applicable power which were received at the first surface. Additionally, the commercial-grade compound refractive X-ray lens includes a plurality of openings which are disposed between the first surface and the second surface. The plurality of openings are oriented such that the X-rays of commercially-applicable power which are received at the first surface, pass through the volume of low-Z material and through the plurality openings. In so doing, the X-rays which emerge from the second surface are refracted to a focal point

  20. Human lens colouration, age and cataract

    International Nuclear Information System (INIS)

    Truscott, R.J.W.; Garner, B.; Hood, B.

    1999-01-01

    Full text: The human lens biosynthesises UV filter compounds which effectively remove light in the 300-400nm band. These chemicals are present either as an aid to visual acuity, or to filter out damaging UV radiation. The primate UV filters are 3-hydroxykynurenine analogues derived from the metabolism of tryptophan. We have recently demonstrated that these endogenous UV filters are not innocuous, but are in fact capable of binding to proteins, including the crystalline proteins which make up the bulk of the lens. Thus, over time, the levels of protein - bound UV filters increase and this results in the human lens becoming progressively more yellow as we age. This colouration affects our colour vision and it may also be responsible for the brown colour of lenses which is the hallmark of age-related nuclear cataract. An understanding of the intrinsic instability of the endogenous UV filters, combined with changes in the internal transport of these and other small molecular weight compounds including antioxidants, such as glutathione, is allowing us to gain an insight into the processes responsible for the development of age-related cataract: the major cause of world blindness

  1. Compound refractive X-ray lens

    Science.gov (United States)

    Nygren, David R.; Cahn, Robert; Cederstrom, Bjorn; Danielsson, Mats; Vestlund, Jonas

    2000-01-01

    An apparatus and method for focusing X-rays. In one embodiment, his invention is a commercial-grade compound refractive X-ray lens. The commercial-grade compound refractive X-ray lens includes a volume of low-Z material. The volume of low-Z material has a first surface which is adapted to receive X-rays of commercially-applicable power emitted from a commercial-grade X-ray source. The volume of low-Z material also has a second surface from which emerge the X-rays of commercially-applicable power which were received at the first surface. Additionally, the commercial-grade compound refractive X-ray lens includes a plurality of openings which are disposed between the first surface and the second surface. The plurality of openings are oriented such that the X-rays of commercially-applicable power which are received at the first surface, pass through the volume of low-Z material and through the plurality openings. In so doing, the X-rays which emerge from the second surface are refracted to a focal point.

  2. Intraocular lens calculations in atypical eyes

    Directory of Open Access Journals (Sweden)

    Aazim A Siddiqui

    2017-01-01

    Full Text Available Cataract surgery is the most performed surgical procedure in the field of ophthalmology. The process of intraocular lens (IOL calculations is a critical step to achieving successful outcomes. Many IOL formulae exist to guide surgeons through the difficult process of picking the most appropriate lens to achieve a certain target refraction. However, these formulae reach within 0.50 diopters of the target refraction only 75% of the time, leaving 25% of the eyes with a significant refractive surprise. A literature review was performed to investigate all the relevant published material on the history, progress, and recent advancements of IOL calculations. Based on this review, the appropriate history, evolution, progress, limitations, and recent advancements are analyzed and explained. Although the modern IOL formulae and biometric devices perform well for average eyes, they are suboptimal for eyes with atypical biometric parameters and also those that are postrefractive and keratoconic. There has not been a single, perfect formula that can resolve the complexities of this process. Various methods of formula optimization and newer generation of IOL formulae and devices may hold the key to improving outcomes in both typical and atypical eyes. These solutions minimize refractive error by introducing new input parameters and complex mathematical techniques to better estimate postoperative lens position.

  3. Two families of astrophysical diverging lens models

    Science.gov (United States)

    Er, Xinzhong; Rogers, Adam

    2018-03-01

    In the standard gravitational lensing scenario, rays from a background source are bent in the direction of a foreground lensing mass distribution. Diverging lens behaviour produces deflections in the opposite sense to gravitational lensing, and is also of astrophysical interest. In fact, diverging lensing due to compact distributions of plasma has been proposed as an explanation for the extreme scattering events that produce frequency-dependent dimming of extragalactic radio sources, and may also be related to the refractive radio wave phenomena observed to affect the flux density of pulsars. In this work we study the behaviour of two families of astrophysical diverging lenses in the geometric optics limit, the power law, and the exponential plasma lenses. Generally, the members of these model families show distinct behaviour in terms of image formation and magnification, however the inclusion of a finite core for certain power-law lenses can produce a caustic and critical curve morphology that is similar to the well-studied Gaussian plasma lens. Both model families can produce dual radial critical curves, a novel distinction from the tangential distortion usually produced by gravitational (converging) lenses. The deflection angle and magnification of a plasma lens vary with the observational frequency, producing wavelength-dependent magnifications that alter the amplitudes and the shape of the light curves. Thus, multiwavelength observations can be used to physically constrain the distribution of the electron density in such lenses.

  4. Design and fabrication of PMMA-micromachined fluid lens based on electromagnetic actuation on PMMA–PDMS bonded membrane

    International Nuclear Information System (INIS)

    Lee, June Kyoo; Park, Kyung-Woo; Choi, Ju Chan; Kim, Hak-Rin; Kong, Seong Ho

    2012-01-01

    The fabrication of a poly(methyl methacrylate) (PMMA)-micromachined fluid lens with an optimally designed built-in electromagnetic actuator was demonstrated in this study. Through a finite element method, the number of winding turns and the distance between magnetic moments were estimated to design an effective and miniaturized electromagnetic actuator. The lens body composed of PMMA structures was simply and rapidly micromachined using computer numerical control micro-milling. The poly(dimethylsiloxane) (PDMS) membranes for electromagnetic actuation were bonded to the PMMA structures by using the proposed PMMA–PDMS bonding technique, which uses an SiO 2 intermediate layer. A physical repulsive force produced by the electromagnetic actuator applies a controllable fluidic pressure to a fluidic chamber that is sealed with the PDMS membrane, thus allowing dynamic focusing. The focus tunability of the fabricated lens was 67 diopters with a focus hysteresis of less than 1 mm and a response time of 2 ms. The solenoid of the built-in actuator showed negligible thermal crosstalk to the lens. (paper)

  5. Radiation dose to the lens and cataract formation

    International Nuclear Information System (INIS)

    Henk, J.M.; Whitelocke, R.A.F.; Warrington, A.P.; Bessell, E.M.

    1993-01-01

    The purpose of this work was to determine the radiation tolerance of the lens of the eye and the incidence of radiation-induced lens changes in patients treated by fractionated supervoltage radiation therapy for orbital tumors. Forty patients treated for orbital lymphoma and pseudotumor with tumor doses of 20--40 Gy were studied. The lens was partly shielded using lead cylinders in most cases. The dose to the germinative zone of the lens was estimated by measurements in a tissue equivalent phantom using both film densitometry and thermoluminescent dosimetry. Opthalmological examination was performed at 6 monthly intervals after treatment. The lead shield was found to reduce the dose to the germinative zone of the lens to between 36--50% of the tumor dose for Cobalt beam therapy, and to between 11--18% for 5 MeV x-rays. Consequently, the lens doses were in the range 4.5--30 Gy in 10--20 fractions. Lens opacities first appeared from between 3 and 9 years after irradiation. Impairment of visual acuity ensued in 74% of the patients who developed lens opacities. The incidence of lens changes was strongly dose-related. None was seen after doses of 5 Gy or lower, whereas doses of 16.5 Gy or higher were all followed by lens opacities which impaired visual acuity. The largest number of patients received a maximum lens dose of 15 Gy; in this group the actuarial incidence of lens opacities at 8 years was 57% with visual impairment in 38%. The adult lens can tolerate a total dose of 5 Gy during a fractionated course of supervoltage radiation therapy without showing any changes. Doses of 16.5 Gy or higher will almost invariably lead to visual impairment. The dose which causes a 50% probability of visual impairment is approximately 15 Gy. 10 refs., 4 figs., 1 tab

  6. Micro-turbines

    International Nuclear Information System (INIS)

    Tashevski, Done

    2003-01-01

    In this paper a principle of micro-turbines operation, type of micro-turbines and their characteristics is presented. It is shown their usage in cogeneration and three generation application with the characteristics, the influence of more factors on micro-turbines operation as well as the possibility for application in Macedonia. The paper is result of the author's participation in the training program 'Micro-turbine technology' in Florida, USA. The characteristics of different types micro-turbines by several world producers are shown, with accent on US micro-turbines producers (Capstone, Elliott). By using the gathered Author's knowledge, contacts and the previous knowledge, conclusions and recommendations for implementation of micro-turbines in Macedonia are given. (Author)

  7. Hybrid Qualifications

    DEFF Research Database (Denmark)

    Against the background of increasing qualification needs there is a growing awareness of the challenge to widen participation in processes of skill formation and competence development. At the same time, the issue of permeability between vocational education and training (VET) and general education...... has turned out as a major focus of European education and training policies and certainly is a crucial principle underlying the European Qualifications Framework (EQF). In this context, «hybrid qualifications» (HQ) may be seen as an interesting approach to tackle these challenges as they serve «two...

  8. Hybrid Gear

    Science.gov (United States)

    Handschuh, Robert F. (Inventor); Roberts, Gary D. (Inventor)

    2016-01-01

    A hybrid gear consisting of metallic outer rim with gear teeth and metallic hub in combination with a composite lay up between the shaft interface (hub) and gear tooth rim is described. The composite lay-up lightens the gear member while having similar torque carrying capability and it attenuates the impact loading driven noise/vibration that is typical in gear systems. The gear has the same operational capability with respect to shaft speed, torque, and temperature as an all-metallic gear as used in aerospace gear design.

  9. Novel Scanning Lens Instrument for Evaluating Fresnel Lens Performance: Equipment Development and Initial Results (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Herrero, R.; Miller, D. C.; Kurtz, S. R.; Anton, I.; Sala, G.

    2013-07-01

    A system dedicated to the optical transmittance characterization of Fresnel lenses has been developed at NREL, in collaboration with the UPM. The system quantifies the optical efficiency of the lens by generating a performance map. The shape of the focused spot may also be analyzed to understand change in the lens performance. The primary instrument components (lasers and CCD detector) have been characterized to confirm their capability for performing optical transmittance measurements. Measurements performed on SoG and PMMA lenses subject to a variety of indoor conditions (e.g., UV and damp heat) identified differences in the optical efficiency of the evaluated lenses, demonstrating the ability of the Scanning Lens Instrument (SLI) to distinguish between the aged lenses.

  10. Hybrid nanomaterial and its applications: IR sensing and energy harvesting

    Science.gov (United States)

    Tseng, Yi-Hsuan

    sensitivity and detection limit were due to the temperature difference between the two junctions formed by the nanohybrid thin film and copper-wire electrodes under asymmetric IR illumination, and the difference between the effective Seebeck coefficient of the nanohybrid thin film and that of the Cu wires. The IR sensor embedded in polydimethylsiloxane (PDMS) layers was also fabricated and tested to demonstrate its potential application as a flexible IR sensor. In another application, energy harvesting, a new type of thermoelectric microgenerator enabled with the SWNTs-CuS nanoparticles hybrid nanomaterial, was fabricated. This type of microgenerator did not require any cooling or heat sink element to maintain the temperature difference or gradient in the device. Instead, the integrated nanomaterials in the device enhanced the local temperature and thus produced and maintained an intrinsic temperature difference or gradient across the microgenerator, thereby converting light and heat directly into electricity. In order to enhance the maximum output voltage, the incoming light had to be focused on the thin film region. A tunable lens was fabricated to collect and focus the ambient light on the thin film to enhance the output voltage of the microgenerators. The tunable lens was fabricated with a flexible polymer, PDMS. Therefore, the focal length of the tunable lens can be adjusted by pumping oil into the lens chamber to deform a PDMS membrane, resulting in the changed focus of the lens. In order to enhance the output power, two different arrays of thermoelectric generators in series and in parallel were fabricated. A hybrid nanomaterial thin film was also used to enhance the temperature gradient of the thermoelectric generators. For the devices in series, the generated voltage of all thermoelectric generators was combined together to enhance the output voltage. With the device in parallel, it can be used to combine all of the current of thermoelectric generators together to

  11. Pentacam Scheimpflug quantitative imaging of the crystalline lens and intraocular lens.

    Science.gov (United States)

    Rosales, Patricia; Marcos, Susana

    2009-05-01

    To implement geometrical and optical distortion correction methods for anterior segment Scheimpflug images obtained with a commercially available system (Pentacam, Oculus Optikgeräte GmbH). Ray tracing algorithms were implemented to obtain corrected ocular surface geometry from the original images captured by the Pentacam's CCD camera. As details of the optical layout were not fully provided by the manufacturer, an iterative procedure (based on imaging of calibrated spheres) was developed to estimate the camera lens specifications. The correction procedure was tested on Scheimpflug images of a physical water cell model eye (with polymethylmethacrylate cornea and a commercial IOL of known dimensions) and of a normal human eye previously measured with a corrected optical and geometrical distortion Scheimpflug camera (Topcon SL-45 [Topcon Medical Systems Inc] from the Vrije University, Amsterdam, Holland). Uncorrected Scheimpflug images show flatter surfaces and thinner lenses than in reality. The application of geometrical and optical distortion correction algorithms improves the accuracy of the estimated anterior lens radii of curvature by 30% to 40% and of the estimated posterior lens by 50% to 100%. The average error in the retrieved radii was 0.37 and 0.46 mm for the anterior and posterior lens radii of curvature, respectively, and 0.048 mm for lens thickness. The Pentacam Scheimpflug system can be used to obtain quantitative information on the geometry of the crystalline lens, provided that geometrical and optical distortion correction algorithms are applied, within the accuracy of state-of-the art phakometry and biometry. The techniques could improve with exact knowledge of the technical specifications of the instrument, improved edge detection algorithms, consideration of aspheric and non-rotationally symmetrical surfaces, and introduction of a crystalline gradient index.

  12. A high excitation magnetic quadrupole lens quadruplet incorporating a single octupole lens for a low spherical aberration probe forming lens system

    Science.gov (United States)

    Dou, Yanxin; Jamieson, David N.; Liu, Jianli; Li, Liyi

    2018-03-01

    This paper describes the design of a new probe forming lens system consisting of a high excitation magnetic quadrupole lens quadruplet that incorporates a single magnetic octupole lens. This system achieves both a high demagnification and a low spherical aberration compared to conventional high excitation systems and is intended for deployment for the Harbin 300 MeV proton microprobe for applications in space science and ion beam therapy. This relative simplicity of the ion optical design to include a single octupole lens minimizes the risks associated with the constructional and operational precision usually needed for the probe forming lens system and this system could also be deployed in microprobe systems that operate with less magnetically rigid ions. The design of the new system is validated with reference to two independent ion optical computer codes.

  13. Multipoint photonic doppler velocimetry using optical lens elements

    Science.gov (United States)

    Frogget, Brent Copely; Romero, Vincent Todd

    2014-04-29

    A probe including a fisheye lens is disclosed to measure the velocity distribution of a moving surface along many lines of sight. Laser light, directed to the surface and then reflected back from the surface, is Doppler shifted by the moving surface, collected into fisheye lens, and then directed to detection equipment through optic fibers. The received light is mixed with reference laser light and using photonic Doppler velocimetry, a continuous time record of the surface movement is obtained. An array of single-mode optical fibers provides an optic signal to an index-matching lens and eventually to a fisheye lens. The fiber array flat polished and coupled to the index-matching lens using index-matching gel. Numerous fibers in a fiber array project numerous rays through the fisheye lens which in turn project many measurement points at numerous different locations to establish surface coverage over a hemispherical shape with very little crosstalk.

  14. Measuring and correcting aberrations of a cathode objective lens

    International Nuclear Information System (INIS)

    Tromp, R.M.

    2011-01-01

    In this paper I discuss several theoretical and practical aspects related to measuring and correcting the chromatic and spherical aberrations of a cathode objective lens as used in Low Energy Electron Microscopy (LEEM) and Photo Electron Emission Microscopy (PEEM) experiments. Special attention is paid to the various components of the cathode objective lens as they contribute to chromatic and spherical aberrations, and affect practical methods for aberration correction. This analysis has enabled us to correct a LEEM instrument for the spherical and chromatic aberrations of the objective lens. -- Research highlights: → Presents a comprehensive theory of the relation between chromatic aberration and lens current in a cathode objective lens. → Presents practical methods for measuring both spherical and chromatic aberrations of a cathode objective lens. → Presents measurements of these aberrations in good agreement with theory. → Presents practical methods for measuring and correcting these aberrations with an electron mirror.

  15. Forensic Analysis of a Contact Lens in a Murder Case.

    Science.gov (United States)

    Zwerling, Charles S

    2016-03-01

    Contact lenses have had rare relevance in trials and/or investigations. After 5 years of burial, orbital remnants were retrieved from an exhumed body and subsequently identified as a key piece of material evidence in a murder trial. The exhumed case materials were evaluated under laboratory conditions and were determined to be contact lens remnants. Contact lens fracture and burial simulation studies were performed to provide additional corroboration of the physical findings of the exhumed contact lens remnants. This material evidence was instrumental in providing factual proof refuting the defendant's testimony in the murder trial. A brief history of contact lens composition and use is provided for understanding the methods and observational results. This forensic case study represents the first published documentation of a contact lens from an exhumed body being used in a murder investigation and establishes an operational procedure for future forensic contact lens examinations. © 2016 American Academy of Forensic Sciences.

  16. The neutron silicon lens. An update of the thermal neutron lens results

    International Nuclear Information System (INIS)

    Johnson, M.W.; Daymond, M.R.

    2001-01-01

    This paper introduces the concept of the Neutron Silicon Lens (NSL) and provides and update on the experimental results achieved to date. The NSL design is a cylindrical neutron lens based on the use of multiple neutron mirrors supported and separated by silicon wafers. Such lenses would have many applications in both the primary and scattered beams on neutron instruments, and would lead to immediate improvements where the sample to be illuminated is small, as in high pressure or engineering strain scanning instruments. (author)

  17. The neutron silicon lens. An update of the thermal neutron lens results

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, M.W.; Daymond, M.R. [Rutherford Appleton Laboratory, Chilton, Didcot, Oxfordshire (United Kingdom)

    2001-03-01

    This paper introduces the concept of the Neutron Silicon Lens (NSL) and provides and update on the experimental results achieved to date. The NSL design is a cylindrical neutron lens based on the use of multiple neutron mirrors supported and separated by silicon wafers. Such lenses would have many applications in both the primary and scattered beams on neutron instruments, and would lead to immediate improvements where the sample to be illuminated is small, as in high pressure or engineering strain scanning instruments. (author)

  18. Intuitionistic hybrid logic

    DEFF Research Database (Denmark)

    Braüner, Torben

    2011-01-01

    Intuitionistic hybrid logic is hybrid modal logic over an intuitionistic logic basis instead of a classical logical basis. In this short paper we introduce intuitionistic hybrid logic and we give a survey of work in the area.......Intuitionistic hybrid logic is hybrid modal logic over an intuitionistic logic basis instead of a classical logical basis. In this short paper we introduce intuitionistic hybrid logic and we give a survey of work in the area....

  19. Surface tension-induced PDMS micro-pillars with controllable tips and tilt angles

    KAUST Repository

    Li, Huawei; Fan, Yiqiang; Conchouso Gonzalez, David; Foulds, Ian G.

    2013-01-01

    This paper reports a novel method to fabricate three-dimensional (3D) polydimethylsiloxane (PDMS) micro-pillars using a CO2 laser-machined poly(methyl methacrylate) (PMMA) mold with through-holes. This method eliminates the requirements of expensive and complicated facilities to fabricate a 3D mold. The micro-pillars were formed by the capillary force that draws PDMS into the through-holes of the PMMA mold. The tilt angles of the micro-pillars depend on the tilt angles of the through-holes in the mold, and the concave and convex micro-lens tip shapes of the PDMS micro-pillars can be modified by changing the surface wettability of the PMMA through-holes.

  20. Surface tension-induced PDMS micro-pillars with controllable tips and tilt angles

    KAUST Repository

    Li, Huawei

    2013-12-21

    This paper reports a novel method to fabricate three-dimensional (3D) polydimethylsiloxane (PDMS) micro-pillars using a CO2 laser-machined poly(methyl methacrylate) (PMMA) mold with through-holes. This method eliminates the requirements of expensive and complicated facilities to fabricate a 3D mold. The micro-pillars were formed by the capillary force that draws PDMS into the through-holes of the PMMA mold. The tilt angles of the micro-pillars depend on the tilt angles of the through-holes in the mold, and the concave and convex micro-lens tip shapes of the PDMS micro-pillars can be modified by changing the surface wettability of the PMMA through-holes.

  1. Design of a nonimaging Fresnel lens for solar concentrators

    Energy Technology Data Exchange (ETDEWEB)

    Leutz, R.; Akisawa, Atushi; Kashiwagi, Takao [Tokyo University of Agriculture and Technology (Japan). Dept. of Mechanical Systems Engineering; Suzuki, Akio [UNESCO, Paris (France)

    1999-04-01

    An optimum convex shaped nonimaging Fresnel lens is designed following the edge ray principle. The lens is evaluated by tracing rays and calculating a projective optical concentration ratio. This Fresnel lens is intended for use in evacuated tube type solar concentrators, generating mid-temperature heat to drive sorption cycles, or provide industrial process heat. It can also be used along with a secondary concentrator in photovoltaic applications. (author)

  2. Freeform Lens Design for Scattering Data with General Radiant Fields

    Science.gov (United States)

    Gutiérrez, Cristian E.; Sabra, Ahmad

    2018-05-01

    We show the existence of a lens, when its lower face is given, such that it refracts radiation emanating from a planar source, with a given field of directions, into the far field that preserves a given distribution of energies. Conditions are shown under which the lens obtained is physically realizable. It is shown that the upper face of the lens satisfies a pde of Monge-Ampère type.

  3. Analysis of phakic before intraocular lens implantation for fundus examination

    OpenAIRE

    Juan Chen; Zhong-Ping Chen; Rui-Ling Zhu

    2014-01-01

    AIM:To investigate the findings of the eyes which were examined preoperatively by three mirror contact lens before the implantation of implantable collamer lens(ICL). To analysis the retinal pathological changes and to explore the clinical analysis of early diagnosis and treatment in retinopathy on fundus examination before operation. METHODS:The retrospective case series study included 127 eyes of 64 patients who underwent phakic intraocular lens implantation were received the fundus examina...

  4. Symbiosis of near breeder HTR's with hybrid fusion reactors

    International Nuclear Information System (INIS)

    Seifritz, W.

    1978-07-01

    In this contribution to INFCE a symbiotic fusion/fission reactor system, consisting of a hybrid beam-driven micro-explosion fusion reactor (HMER) and associated high-temperature gas-cooled reactors (HTR) with a coupled fuel cycle, is proposed. This system is similar to the well known Fast Breeder/Near Breeder HTR symbiosis except that the fast fission breeder - running on the U/Pu-cycle in the core and the axial blankets and breeding the surplus fissile material as U-233 in its radial thorium metal or thorium oxide blankets - is replaced by a hybrid micro-explosion DT fusion reactor

  5. Wide-range tunable magnetic lens for tabletop electron microscope

    International Nuclear Information System (INIS)

    Chang, Wei-Yu; Chen, Fu-Rong

    2016-01-01

    A tabletop scanning electron microscope (SEM) utilizes permanent magnets as condenser lenses to minimize its size, but this sacrifices the tunability of condenser lenses such that a tabletop system can only be operated with a fixed accelerating voltage. In contrast, the traditional condenser lens utilizes an electromagnetic coil to adjust the optical properties, but the size of the electromagnetic lens is inevitably larger. Here, we propose a tunable condenser lens for a tabletop SEM that uses a combination of permanent magnets and electromagnetic coils. The overall dimensions of the newly designed lens are the same as the original permanent magnet lens, but the new lens allows the tabletop SEM to be operated at different accelerating voltages between 1 kV and 15 kV. - Highlights: • A compact condenser lens combines both permanent magnet and coils. • A tunable lens is designed to keep the same focal point for voltage 1 to 15 kV. • A miniature tunable lens which can directly fit into tabletop SEM.

  6. Effects of Coupling Lens on Optical Refrigeration of Semiconductors

    International Nuclear Information System (INIS)

    Kai, Ding; Yi-Ping, Zeng

    2008-01-01

    Optical refrigeration of semiconductors is encountering efficiency difficulties caused by nonradiative recombination and luminescence trapping. A commonly used approach for enhancing luminescence efficiency of a semiconductor device is coupling a lens with the device. We quantitatively study the effects of a coupling lens on optical refrigeration based on rate equations and photon recycling, and calculated cooling efficiencies of different coupling mechanisms and of different lens materials. A GaAs/GaInP heterostructure coupled with a homo-epitaxial GaInP hemispherical lens is recommended. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  7. Lens regeneration in axolotl: new evidence of developmental plasticity

    Directory of Open Access Journals (Sweden)

    Suetsugu-Maki Rinako

    2012-12-01

    Full Text Available Abstract Background Among vertebrates lens regeneration is most pronounced in newts, which have the ability to regenerate the entire lens throughout their lives. Regeneration occurs from the dorsal iris by transdifferentiation of the pigment epithelial cells. Interestingly, the ventral iris never contributes to regeneration. Frogs have limited lens regeneration capacity elicited from the cornea during pre-metamorphic stages. The axolotl is another salamander which, like the newt, regenerates its limbs or its tail with the spinal cord, but up until now all reports have shown that it does not regenerate the lens. Results Here we present a detailed analysis during different stages of axolotl development, and we show that despite previous beliefs the axolotl does regenerate the lens, however, only during a limited time after hatching. We have found that starting at stage 44 (forelimb bud stage lens regeneration is possible for nearly two weeks. Regeneration occurs from the iris but, in contrast to the newt, regeneration can be elicited from either the dorsal or the ventral iris and, occasionally, even from both in the same eye. Similar studies in the zebra fish concluded that lens regeneration is not possible. Conclusions Regeneration of the lens is possible in the axolotl, but differs from both frogs and newts. Thus the axolotl iris provides a novel and more plastic strategy for lens regeneration.

  8. Adaptive mechanical-wetting lens actuated by ferrofluids

    Science.gov (United States)

    Cheng, Hui-Chuan; Xu, Su; Liu, Yifan; Levi, Shoshana; Wu, Shin-Tson

    2011-04-01

    We report an adaptive mechanical-wetting lens actuated by ferrofluids. The ferrofluids works like a piston to pump liquids in and out from the lens chamber, which in turn reshapes the lens curvature and changes the focal length. Both positive and negative lenses are demonstrated experimentally. The ferrofluid-actuated mechanical-wetting lens exhibits some attractive features, such as high resolution, fast response time, low power consumption, simple structure and electronic control, weak gravity effect, and low cost. Its potential applications in medical imaging, surveillance, and commercial electronics are foreseeable.

  9. Particle swarm optimization applied to automatic lens design

    Science.gov (United States)

    Qin, Hua

    2011-06-01

    This paper describes a novel application of Particle Swarm Optimization (PSO) technique to lens design. A mathematical model is constructed, and merit functions in an optical system are employed as fitness functions, which combined radiuses of curvature, thicknesses among lens surfaces and refractive indices regarding an optical system. By using this function, the aberration correction is carried out. A design example using PSO is given. Results show that PSO as optical design tools is practical and powerful, and this method is no longer dependent on the lens initial structure and can arbitrarily create search ranges of structural parameters of a lens system, which is an important step towards automatic design with artificial intelligence.

  10. Wide-range tunable magnetic lens for tabletop electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Wei-Yu; Chen, Fu-Rong, E-mail: fchen1@me.com

    2016-12-15

    A tabletop scanning electron microscope (SEM) utilizes permanent magnets as condenser lenses to minimize its size, but this sacrifices the tunability of condenser lenses such that a tabletop system can only be operated with a fixed accelerating voltage. In contrast, the traditional condenser lens utilizes an electromagnetic coil to adjust the optical properties, but the size of the electromagnetic lens is inevitably larger. Here, we propose a tunable condenser lens for a tabletop SEM that uses a combination of permanent magnets and electromagnetic coils. The overall dimensions of the newly designed lens are the same as the original permanent magnet lens, but the new lens allows the tabletop SEM to be operated at different accelerating voltages between 1 kV and 15 kV. - Highlights: • A compact condenser lens combines both permanent magnet and coils. • A tunable lens is designed to keep the same focal point for voltage 1 to 15 kV. • A miniature tunable lens which can directly fit into tabletop SEM.

  11. [Phacoemulsification of subluxated lens with capsular tension ring implantation].

    Science.gov (United States)

    Dorecka, Mariola; Rokicki, Wojciech; Nita, Malgorzata; Krysik, Katarzyna; Nita, Ewa; Sikorska, Aleksandra; Romaniuk, Wanda

    2007-01-01

    To evaluate long term results of phacoemulsification with PC IOL and capsular tension ring (CTR) implantation in lens subluxation. The study comprised of 134 patients--146 eyes with subluxated lens. In all cases phacoemulsification with PC IOL and CTR implantation was performed. No intaroperative complications has occured. Postoperative complications included: inflammation in the anterior chamber in 3 eyes (2.1%), retinal detachment in 2 eyes (1.4%). In all cases there was no PC IOL decentration. (1) CTR facilitates phacoemulsification with PC IOL implantation in lens subluxation. (2) Phacoemulsification of subluxated lens with PC IOL and CTR implantation seems to be safe and effective procedure.

  12. Flat dielectric metasurface lens array for three dimensional integral imaging

    Science.gov (United States)

    Zhang, Jianlei; Wang, Xiaorui; Yang, Yi; Yuan, Ying; Wu, Xiongxiong

    2018-05-01

    In conventional integral imaging, the singlet refractive lens array limits the imaging performance due to its prominent aberrations. Different from the refractive lens array relying on phase modulation via phase change accumulated along the optical paths, metasurfaces composed of nano-scatters can produce phase abrupt over the scale of wavelength. In this letter, we propose a novel lens array consisting of two neighboring flat dielectric metasurfaces for integral imaging system. The aspherical phase profiles of the metasurfaces are optimized to improve imaging performance. The simulation results show that our designed 5 × 5 metasurface-based lens array exhibits high image quality at designed wavelength 865 nm.

  13. Lubricant effects on low Dk and silicone hydrogel lens comfort.

    Science.gov (United States)

    Ozkan, Jerome; Papas, Eric

    2008-08-01

    To investigate the influence of three lubricants of varying viscosity, on postinsertion and 6 h comfort with contact lens wear. Comfort and associated symptoms of dryness were assessed in 15 experienced contact lens wearers. Subjects wore a low Dk lens in one eye and a silicone hydrogel in the other and participated in four separate trials involving no lubricant (baseline), saline, and two commercially available lubricants of differing viscosity. The in-eye lubricants were used immediately following lens insertion and every 2 h postinsertion for a 6 h wear period. Postlens insertion comfort was significantly better for both lens types when lubricants or saline were used compared with no lubricant use. After 6 h lens wear, comfort was influenced by lens type and not by in-eye lubricant or saline use. Also after 6 h lens wear, less dryness sensation was reported for silicone hydrogel lenses when using lubricants but not saline. Although lubricant use does help reduce dryness symptoms with silicone hydrogel lens wear, there appears to be minimal longer-term benefit to comfort. Furthermore, increased lubricant viscosity did not lead to improved longer-term comfort.

  14. Hybrid numerical calculation method for bend waveguides

    OpenAIRE

    Garnier , Lucas; Saavedra , C.; Castro-Beltran , Rigoberto; Lucio , José Luis; Bêche , Bruno

    2017-01-01

    National audience; The knowledge of how the light will behave in a waveguide with a radius of curvature becomes more and more important because of the development of integrated photonics, which include ring micro-resonators, phasars, and other devices with a radius of curvature. This work presents a numerical calculation method to determine the eigenvalues and eigenvectors of curved waveguides. This method is a hybrid method which uses at first conform transformation of the complex plane gene...

  15. Hybridized Tetraquarks

    CERN Document Server

    Esposito, A.; Polosa, A.D.

    2016-01-01

    We propose a new interpretation of the neutral and charged X, Z exotic hadron resonances. Hybridized-tetraquarks are neither purely compact tetraquark states nor bound or loosely bound molecules. The latter would require a negative or zero binding energy whose counterpart in h-tetraquarks is a positive quantity. The formation mechanism of this new class of hadrons is inspired by that of Feshbach metastable states in atomic physics. The recent claim of an exotic resonance in the Bs pi+- channel by the D0 collaboration and the negative result presented subsequently by the LHCb collaboration are understood in this scheme, together with a considerable portion of available data on X, Z particles. Considerations on a state with the same quantum numbers as the X(5568) are also made.

  16. Influence of Gravity on Ocular Lens Position.

    Science.gov (United States)

    Lister, Lucas J; Suheimat, Marwan; Verkicharla, Pavan K; Mallen, Edward A H; Atchison, David A

    2016-04-01

    We determined whether human ocular lens position is influenced by gravity. Anterior chamber depth (ACD) and lens thickness (LT) were determined with a Haag-Streit Lenstar LS900 for right eyes of participants in two age groups, with a young group of 13 participants aged 18 to 21 years (mean, 21 years; SD, 1 year) and an older group of 10 participants aged 50 to 63 years (mean, 58 years; SD, 4 years). There were two sessions for each participant separated by at least 48 hours, with one session for the usual upright head position and one session for a downwards head position. In a session, testing was done for minimum accommodation followed by testing at maximum accommodation. A drop of 2% pilocarpine nitrate was instilled, and testing was repeated after 30 minutes under minimum and maximum accommodation conditions. Gravity, manipulated through head posture, affected ACD for young adult and older adult groups but mean effects were only small, ranging from 0.04 to 0.12 mm, and for the older group required the instillation of an accommodation-stimulating drug. Gravity had a weakly significant effect on LT for the young group without accommodation or a drug, but the effect was small at 0.04 ± 0.06 mm (mean ± SD, P = 0.04). There is a small but real effect of gravity on crystalline lens position, manifested as reduction in ACD at high levels of accommodative effort with the head in a downwards position. This provides evidence of the ability of zonules to slacken during strong accommodation.

  17. Micro-propulsion and micro-combustion; Micropropulsion microcombustion

    Energy Technology Data Exchange (ETDEWEB)

    Ribaud, Y.; Dessornes, O.

    2002-10-01

    The AAAF (french space and aeronautic association) organized at Paris a presentation on the micro-propulsion. The first part was devoted to the thermal micro-machines for micro drones, the second part to the micro-combustion applied to micro-turbines. (A.L.B.)

  18. Abnormal lens morphogenesis and ectopic lens formation in the absence of beta-catenin function

    Czech Academy of Sciences Publication Activity Database

    Krešlová, Jana; Machoň, Ondřej; Růžičková, Jana; Láchová, Jitka; Wawrousek, E.F.; Kemler, R.; Krauss, S.; Piatigorsky, J.; Kozmik, Zbyněk

    2007-01-01

    Roč. 45, č. 4 (2007), s. 157-168 ISSN 1526-954X R&D Projects: GA ČR GA204/04/1358 Institutional research plan: CEZ:AV0Z50520514 Keywords : Wnt * beta-catenin * gene * lens Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 2.516, year: 2007

  19. High Dk piggyback contact lens system for contact lens-intolerant keratoconus patients.

    Science.gov (United States)

    Sengor, Tomris; Kurna, Sevda Aydin; Aki, Suat; Ozkurt, Yelda

    2011-01-01

    The aim of the study was to examine the clinical success of high Dk (oxygen permeability) piggyback contact lens (PBCL) systems for the correction of contact lens intolerant keratoconus patients. Sixteen patients (29 eyes) who were not able to wear gas-permeable rigid lenses were included in this study. Hyper Dk silicone hydrogel (oxygen transmissibility or Dk/t = 150 units) and fluorosilicone methacrylate copolymer (Dk/t = 100 units) lenses were chosen as the PBCL systems. The clinical examinations included visual acuity and corneal observation by biomicroscopy, keratometer reading, and fluorescein staining before and after fitting the PBCL system. INDICATIONS FOR USING PBCL SYSTEM WERE: lens stabilization and comfort, improving comfort, and adding protection to the cone. Visual acuities increased significantly in all of the patients compared with spectacles (P = 0). Improvement in visual acuity compared with rigid lenses alone was recorded in 89.7% of eyes and no alteration of the visual acuity was observed in 10.3% of the eyes. Wearing time of PBCL systems for most of the patients was limited time (mean 6 months, range 3-12 months); thereafter they tolerated rigid lenses alone except for 2 patients. The PBCL system is a safe and effective method to provide centering and corneal protection against mechanical trauma by the rigid lenses for keratoconus patients and may increase contact lens tolerance.

  20. Polarization response of RHIC electron lens lattices

    International Nuclear Information System (INIS)

    Ranjbar, V. H.; Méot, F.; Bai, M.; Abell, D. T.; Meiser, D.

    2016-01-01

    Depolarization response for a system of two orthogonal snakes at irrational tunes is studied in depth using lattice independent spin integration. Particularly, we consider the effect of overlapping spin resonances in this system, to understand the impact of phase, tune, relative location and threshold strengths of the spin resonances. Furthermore, these results are benchmarked and compared to two dimensional direct tracking results for the RHIC e-lens lattice and the standard lattice. We then consider the effect of longitudinal motion via chromatic scans using direct six dimensional lattice tracking.

  1. Polarization response of RHIC electron lens lattices

    Directory of Open Access Journals (Sweden)

    V. H. Ranjbar

    2016-10-01

    Full Text Available Depolarization response for a system of two orthogonal snakes at irrational tunes is studied in depth using lattice independent spin integration. In particular we consider the effect of overlapping spin resonances in this system, to understand the impact of phase, tune, relative location and threshold strengths of the spin resonances. These results are benchmarked and compared to two dimensional direct tracking results for the RHIC e-lens lattice and the standard lattice. Finally we consider the effect of longitudinal motion via chromatic scans using direct six dimensional lattice tracking.

  2. Micro-Organ Device

    Science.gov (United States)

    Gonda, Steve R. (Inventor); Chang, Robert C. (Inventor); Starly, Binil (Inventor); Culbertson, Christopher (Inventor); Holtorf, Heidi L. (Inventor); Sun, Wei (Inventor); Leslie, Julia (Inventor)

    2013-01-01

    A method for fabricating a micro-organ device comprises providing a microscale support having one or more microfluidic channels and one or more micro-chambers for housing a micro-organ and printing a micro-organ on the microscale support using a cell suspension in a syringe controlled by a computer-aided tissue engineering system, wherein the cell suspension comprises cells suspended in a solution containing a material that functions as a three-dimensional scaffold. The printing is performed with the computer-aided tissue engineering system according to a particular pattern. The micro-organ device comprises at least one micro-chamber each housing a micro-organ; and at least one microfluidic channel connected to the micro-chamber, wherein the micro-organ comprises cells arranged in a configuration that includes microscale spacing between portions of the cells to facilitate diffusion exchange between the cells and a medium supplied from the at least one microfluidic channel.

  3. Candidate gravitational microlensing events for future direct lens imaging

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, C. B.; Gould, A.; Gaudi, B. S. [Department of Astronomy, The Ohio State University, 140 West 18th Avenue, Columbus, OH 43210 (United States); Park, H.; Han, C. [Department of Physics, Institute for Astrophysics, Chungbuk National University, Cheongju 371-763 (Korea, Republic of); Sumi, T.; Koshimoto, N. [Department of Earth and Space Science, Osaka University, Osaka 560-0043 (Japan); Udalski, A. [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland); Tsapras, Y. [Las Cumbres Observatory Global Telescope Network, 6740 Cortona Drive, Suite 102, Goleta, CA 93117 (United States); Bozza, V. [Department of Physics, University of Salerno, I-84084 Fisciano (Italy); Abe, F.; Fukunaga, D.; Itow, Y.; Masuda, K. [Solar-Terrestrial Environment Laboratory, Nagoya University, Nagoya 464-8601 (Japan); Bennett, D. P. [Department of Physics, University of Notre Dame, 225 Nieuwland Science Hall, Notre Dame, IN 46556-5670 (United States); Bond, I. A.; Ling, C. H. [Institute of Information and Mathematical Sciences, Massey University, Private Bag 102-904, North Shore Mail Centre, Auckland 0745 (New Zealand); Botzler, C. S.; Freeman, M. [Department of Physics, University of Auckland, Private Bag 92-019, Auckland 1001 (New Zealand); Fukui, A. [School of Chemical and Physical Sciences, Victoria University, Wellington 6140 (New Zealand); Collaboration: MOA Collaboration; OGLE Collaboration; μFUN Collaboration; RoboNet Collaboration; and others

    2014-10-10

    The mass of the lenses giving rise to Galactic microlensing events can be constrained by measuring the relative lens-source proper motion and lens flux. The flux of the lens can be separated from that of the source, companions to the source, and unrelated nearby stars with high-resolution images taken when the lens and source are spatially resolved. For typical ground-based adaptive optics (AO) or space-based observations, this requires either inordinately long time baselines or high relative proper motions. We provide a list of microlensing events toward the Galactic bulge with high relative lens-source proper motion that are therefore good candidates for constraining the lens mass with future high-resolution imaging. We investigate all events from 2004 to 2013 that display detectable finite-source effects, a feature that allows us to measure the proper motion. In total, we present 20 events with μ ≳ 8 mas yr{sup –1}. Of these, 14 were culled from previous analyses while 6 are new, including OGLE-2004-BLG-368, MOA-2005-BLG-36, OGLE-2012-BLG-0211, OGLE-2012-BLG-0456, MOA-2012-BLG-532, and MOA-2013-BLG-029. In ≲12 yr from the time of each event the lens and source of each event will be sufficiently separated for ground-based telescopes with AO systems or space telescopes to resolve each component and further characterize the lens system. Furthermore, for the most recent events, comparison of the lens flux estimates from images taken immediately to those estimated from images taken when the lens and source are resolved can be used to empirically check the robustness of the single-epoch method currently being used to estimate lens masses for many events.

  4. Computer optimization of retarding lens systems for ESCA spectrometers

    International Nuclear Information System (INIS)

    Wannberg, B.; Skoellermo, A.

    1977-01-01

    The performance of four-element electrostatic lenses as retarding systems between source and analyzer in ESCA spectrometers is calculated. The potential distribution in the lens is defined by an axial potential of the type phi(z)=V 0 +Σ(Vsub(i)-Vsub(i-1))/2 - tanh (ω/asub(i)(z-zsub(i))). For a given general shape of the lens and a given retardation ratio, the potentials of the two middle electrodes are fitted to give a paraxial image with a prescribed magnification at the exit slit of the lens system. The equipotential surfaces forming the electrodes are found by calculating the potential in an off-axis point, using the series expansion. All third-order geometrical and first-order chromatic aberrations of the lenses are calculated and used together with the second-order aberrations of the analyzer to calculate optimum dimensions of the lens elements and of the emittance-defining slits. A computer program, of which one part calculates the lens properties and one the properties of the entire system lens-analyzer, is described. Two lens systems are presented in some detail. The first one is intended for use with a hemispherical electrostatic analyzer. The angular acceptance is here defined by an aperture stop inside the lens. In this system, the image position and magnification can be kept constant for retardation ratios at least between 1:2 and 60:1, with moderate potentials on the middle electrodes. The second lens system is designed for a magnetic spectrometer of the π√2-type. Here, the central trajectory in the lens is slightly curved by the magnetic field, and the angular acceptance is defined by a baffle after the lens. This system is optimized for a constant retardation ratio of 5:1. (Auth.)

  5. Candidate gravitational microlensing events for future direct lens imaging

    International Nuclear Information System (INIS)

    Henderson, C. B.; Gould, A.; Gaudi, B. S.; Park, H.; Han, C.; Sumi, T.; Koshimoto, N.; Udalski, A.; Tsapras, Y.; Bozza, V.; Abe, F.; Fukunaga, D.; Itow, Y.; Masuda, K.; Bennett, D. P.; Bond, I. A.; Ling, C. H.; Botzler, C. S.; Freeman, M.; Fukui, A.

    2014-01-01

    The mass of the lenses giving rise to Galactic microlensing events can be constrained by measuring the relative lens-source proper motion and lens flux. The flux of the lens can be separated from that of the source, companions to the source, and unrelated nearby stars with high-resolution images taken when the lens and source are spatially resolved. For typical ground-based adaptive optics (AO) or space-based observations, this requires either inordinately long time baselines or high relative proper motions. We provide a list of microlensing events toward the Galactic bulge with high relative lens-source proper motion that are therefore good candidates for constraining the lens mass with future high-resolution imaging. We investigate all events from 2004 to 2013 that display detectable finite-source effects, a feature that allows us to measure the proper motion. In total, we present 20 events with μ ≳ 8 mas yr –1 . Of these, 14 were culled from previous analyses while 6 are new, including OGLE-2004-BLG-368, MOA-2005-BLG-36, OGLE-2012-BLG-0211, OGLE-2012-BLG-0456, MOA-2012-BLG-532, and MOA-2013-BLG-029. In ≲12 yr from the time of each event the lens and source of each event will be sufficiently separated for ground-based telescopes with AO systems or space telescopes to resolve each component and further characterize the lens system. Furthermore, for the most recent events, comparison of the lens flux estimates from images taken immediately to those estimated from images taken when the lens and source are resolved can be used to empirically check the robustness of the single-epoch method currently being used to estimate lens masses for many events.

  6. Piggyback intraocular lens implantation to correct pseudophakic refractive error after segmental multifocal intraocular lens implantation.

    Science.gov (United States)

    Venter, Jan A; Oberholster, Andre; Schallhorn, Steven C; Pelouskova, Martina

    2014-04-01

    To evaluate refractive and visual outcomes of secondary piggyback intraocular lens implantation in patients diagnosed as having residual ametropia following segmental multifocal lens implantation. Data of 80 pseudophakic eyes with ametropia that underwent Sulcoflex aspheric 653L intraocular lens implantation (Rayner Intraocular Lenses Ltd., East Sussex, United Kingdom) to correct residual refractive error were analyzed. All eyes previously had in-the-bag zonal refractive multifocal intraocular lens implantation (Lentis Mplus MF30, models LS-312 and LS-313; Oculentis GmbH, Berlin, Germany) and required residual refractive error correction. Outcome measurements included uncorrected distance visual acuity, corrected distance visual acuity, uncorrected near visual acuity, distance-corrected near visual acuity, manifest refraction, and complications. One-year data are presented in this study. The mean spherical equivalent ranged from -1.75 to +3.25 diopters (D) preoperatively (mean: +0.58 ± 1.15 D) and reduced to -1.25 to +0.50 D (mean: -0.14 ± 0.28 D; P < .01). Postoperatively, 93.8% of eyes were within ±0.50 D and 98.8% were within ±1.00 D of emmetropia. The mean uncorrected distance visual acuity improved significantly from 0.28 ± 0.16 to 0.01 ± 0.10 logMAR and 78.8% of eyes achieved 6/6 (Snellen 20/20) or better postoperatively. The mean uncorrected near visual acuity changed from 0.43 ± 0.28 to 0.19 ± 0.15 logMAR. There was no significant change in corrected distance visual acuity or distance-corrected near visual acuity. No serious intraoperative or postoperative complications requiring secondary intraocular lens removal occurred. Sulcoflex lenses proved to be a predictable and safe option for correcting residual refractive error in patients diagnosed as having pseudophakia. Copyright 2014, SLACK Incorporated.

  7. Impact of lens case hygiene guidelines on contact lens case contamination.

    Science.gov (United States)

    Wu, Yvonne T; Teng, Yuu Juan; Nicholas, Mary; Harmis, Najat; Zhu, Hua; Willcox, Mark D P; Stapleton, Fiona

    2011-10-01

    Lens case contamination is a risk factor for microbial keratitis. The effectiveness of manufacturers' lens case cleaning guidelines in limiting microbial contamination has not been evaluated in vivo. This study compared the effectiveness of manufacturers' guidelines and an alternative cleaning regimen. A randomized cross-over clinical trial with two phases (n = 40) was performed. Participants used the lens types of their choice in conjunction with the provided multipurpose solution (containing polyhexamethylene biguanide) for daily wear. In the manufacturers' guideline phase, cases were rinsed with multipurpose solution and air dried. In the alternative regimen phase, cases were rubbed, rinsed with solution, tissue wiped, and air-dried face down. The duration of each phase was 1 month. Lens cases were collected at the end of each phase for microbiological investigation. The levels of microbial contamination were compared, and compliance to both regimens was assessed. The case contamination rate was 82% (32/39) in the manufacturers' guideline group, compared with 72% (28/39) in the alternative regimen group. There were significantly fewer (p = 0.004) colony forming units (CFU) of bacteria from cases used by following the alternative regimen (CFU range of 0 to 10, and median of 12 CFU per well) compared with that of the manufacturer's guidelines (CFU range of 0 to 10, and median of 28 CFU per well). The compliance level between both guidelines was not significantly different (p > 0.05). The alternative guidelines are more effective in eliminating microbial contamination from lens cases than that of the current manufacturer's guideline. Simply incorporating rubbing and tissue-wiping steps in daily case hygiene reduces viable organism contamination.

  8. Rat silicone hydrogel contact lens model: effects of high- versus low-Dk lens wear.

    Science.gov (United States)

    Zhang, Yunfan; Gabriel, Manal M; Mowrey-McKee, Mary F; Barrett, Ronald P; McClellan, Sharon; Hazlett, Linda D

    2008-11-01

    This study used a rat contact lens (CL) model to test if high- versus low-Dk lens wear caused changes in (1) conjunctival Langerhans cell (LC) number or location; (2) Bcl-2 expression; and (3) infection risk. Female, Lewis rats wore a high- or low-Dk CL continuously for 2 weeks. Afterward, corneas were harvested and processed for ADPase activity to identify LCs, for immunostaining and for real time-polymerase chain reaction. Contact lens-wearing rats also were challenged with Pseudomonas aeruginosa by placing a bacterial-soaked CL on the eye followed by topical delivery of bacteria. After 48 hrs, slit lamp examination and real time-polymerase chain reaction were used to evaluate the corneal response. Conjunctival LC were significantly increased after low- versus high-Dk CL wear (PDk lens wearing group. Bcl-2 mRNA levels were significantly decreased in low- versus high-Dk CL wearing rats, while Bax, FasL, caspase 3, and caspase 9 levels were unchanged. Immunostaining for Bcl-2 showed fewer positively stained epithelial cells in the low- versus high-Dk lens wearing group. After bacterial challenge, 30% of low- versus none of the high-Dk CL wearing corneas became infected and showed increased mRNA levels for several proinflammatory cytokines/chemokines, inducible nitric oxide synthase and matrix metalloproteinase-9. Low- versus high-Dk or non-CL wear led to an increased number of conjunctival LC, decreased Bcl-2 levels, and increased the risk of bacterial infection.

  9. Continuity controlled Hybrid Automata

    NARCIS (Netherlands)

    Bergstra, J.A.; Middelburg, C.A.

    We investigate the connections between the process algebra for hybrid systems of Bergstra and Middelburg and the formalism of hybrid automata of Henzinger et al. We give interpretations of hybrid automata in the process algebra for hybrid systems and compare them with the standard interpretation

  10. Continuity Controlled Hybrid Automata

    NARCIS (Netherlands)

    Bergstra, J.A.; Middelburg, C.A.

    2004-01-01

    We investigate the connections between the process algebra for hybrid systems of Bergstra and Middelburg and the formalism of hybrid automata of Henzinger et al. We give interpretations of hybrid automata in the process algebra for hybrid systems and compare them with the standard interpretation of

  11. Continuity controlled hybrid automata

    NARCIS (Netherlands)

    Bergstra, J.A.; Middelburg, C.A.

    2004-01-01

    We investigate the connections between the process algebra for hybrid systems of Bergstra and Middelburg and the formalism of hybrid automata of Henzinger et al. We give interpretations of hybrid automata in the process algebra for hybrid systems and compare them with the standard interpretation of

  12. Continuity controlled hybrid automata

    NARCIS (Netherlands)

    Bergstra, J.A.; Middelburg, C.A.

    2006-01-01

    We investigate the connections between the process algebra for hybrid systems of Bergstra and Middelburg and the formalism of hybrid automata of Henzinger et al. We give interpretations of hybrid automata in the process algebra for hybrid systems and compare them with the standard interpretation of

  13. 'Micro-8' micro-computer system

    International Nuclear Information System (INIS)

    Yagi, Hideyuki; Nakahara, Yoshinori; Yamada, Takayuki; Takeuchi, Norio; Koyama, Kinji

    1978-08-01

    The micro-computer Micro-8 system has been developed to organize a data exchange network between various instruments and a computer group including a large computer system. Used for packet exchangers and terminal controllers, the system consists of ten kinds of standard boards including a CPU board with INTEL-8080 one-chip-processor. CPU architecture, BUS architecture, interrupt control, and standard-boards function are explained in circuit block diagrams. Operations of the basic I/O device, digital I/O board and communication adapter are described with definitions of the interrupt ramp status, I/O command, I/O mask, data register, etc. In the appendixes are circuit drawings, INTEL-8080 micro-processor specifications, BUS connections, I/O address mappings, jumper connections of address selection, and interface connections. (author)

  14. Curiosity's Mars Hand Lens Imager (MAHLI) Investigation

    Science.gov (United States)

    Edgett, Kenneth S.; Yingst, R. Aileen; Ravine, Michael A.; Caplinger, Michael A.; Maki, Justin N.; Ghaemi, F. Tony; Schaffner, Jacob A.; Bell, James F.; Edwards, Laurence J.; Herkenhoff, Kenneth E.; Heydari, Ezat; Kah, Linda C.; Lemmon, Mark T.; Minitti, Michelle E.; Olson, Timothy S.; Parker, Timothy J.; Rowland, Scott K.; Schieber, Juergen; Sullivan, Robert J.; Sumner, Dawn Y.; Thomas, Peter C.; Jensen, Elsa H.; Simmonds, John J.; Sengstacken, Aaron J.; Wilson, Reg G.; Goetz, Walter

    2012-01-01

    The Mars Science Laboratory (MSL) Mars Hand Lens Imager (MAHLI) investigation will use a 2-megapixel color camera with a focusable macro lens aboard the rover, Curiosity, to investigate the stratigraphy and grain-scale texture, structure, mineralogy, and morphology of geologic materials in northwestern Gale crater. Of particular interest is the stratigraphic record of a ?5 km thick layered rock sequence exposed on the slopes of Aeolis Mons (also known as Mount Sharp). The instrument consists of three parts, a camera head mounted on the turret at the end of a robotic arm, an electronics and data storage assembly located inside the rover body, and a calibration target mounted on the robotic arm shoulder azimuth actuator housing. MAHLI can acquire in-focus images at working distances from ?2.1 cm to infinity. At the minimum working distance, image pixel scale is ?14 μm per pixel and very coarse silt grains can be resolved. At the working distance of the Mars Exploration Rover Microscopic Imager cameras aboard Spirit and Opportunity, MAHLI?s resolution is comparable at ?30 μm per pixel. Onboard capabilities include autofocus, auto-exposure, sub-framing, video imaging, Bayer pattern color interpolation, lossy and lossless compression, focus merging of up to 8 focus stack images, white light and longwave ultraviolet (365 nm) illumination of nearby subjects, and 8 gigabytes of non-volatile memory data storage.

  15. Crystal diffraction lens for medical imaging

    International Nuclear Information System (INIS)

    Smither, R. K.; Roa, D. E.

    2000-01-01

    A crystal diffraction lens for focusing energetic gamma rays has been developed at Argonne National Laboratory for use in medical imaging of radioactivity in the human body. A common method for locating possible cancerous growths in the body is to inject radioactivity into the blood stream of the patient and then look for any concentration of radioactivity that could be associated with the fast growing cancer cells. Often there are borderline indications of possible cancers that could be due to statistical functions in the measured counting rates. In order to determine if these indications are false or real, one must resort to surgical means and take tissue samples in the suspect area. They are developing a system of crystal diffraction lenses that will be incorporated into a 3-D imaging system with better sensitivity (factors of 10 to 100) and better spatial resolution (a few mm in both vertical and horizontal directions) than most systems presently in use. The use of this new imaging system will allow one to eliminate 90% of the false indications and both locate and determine the size of the cancer with mm precision. The lens consists of 900 single crystals of copper, 4 mm x 4 mm on a side and 2--4 mm thick, mounted in 13 concentric rings

  16. Dose limits to the eye lens

    Energy Technology Data Exchange (ETDEWEB)

    Sion, N.

    2016-09-15

    Protecting the human body from the effects of ionizing radiation is essential to forestall stochastic effects and require placing limits on the effective dose. Dose limits on specific organs are also necessary to reduce the deterministic effects and tissue reactions. The standard for radiation protection was ISO 15382 (2002) which mainly dealt with beta radiation for nuclear power plant workers. Clearly an update is required to allow for new technology and the proliferative use of radiation in medical practices. There is a need for more explicit radiation monitoring to operators and staff. ICRP118 (International Commission on Radiological Protection), Ref. 1, evolved their recommendations to include eye lens doses as a follow on to their publication 103 and to focus on radiation exposures. It provides updated estimates of 'practical' threshold doses for tissue injury at the level of 1% incidence. This paper discusses the current status and the recommendation for a drastic reduction of the dose limit to the eye lens. (author)

  17. Recent advances in micro-vibration isolation

    Science.gov (United States)

    Liu, Chunchuan; Jing, Xingjian; Daley, Steve; Li, Fengming

    2015-05-01

    Micro-vibration caused by disturbance sources onboard spacecraft can severely degrade the working environment of sensitive payloads. Some notable vibration control methods have been developed particularly for the suppression or isolation of micro-vibration over recent decades. Usually, passive isolation techniques are deployed in aerospace engineering. Active isolators, however, are often proposed to deal with the low frequency vibration that is common in spacecraft. Active/passive hybrid isolation has also been effectively used in some spacecraft structures for a number of years. In semi-active isolation systems, the inherent structural performance can be adjusted to deal with variation in the aerospace environment. This latter approach is potentially one of the most practical isolation techniques for micro-vibration isolation tasks. Some emerging advanced vibration isolation methods that exploit the benefits of nonlinearity have also been reported in the literature. This represents an interesting and highly promising approach for solving some challenging problems in the area. This paper serves as a state-of-the-art review of the vibration isolation theory and/or methods which were developed, mainly over the last decade, specifically for or potentially could be used for, micro-vibration control.

  18. The NNEST lens non native english speakers in TESOL

    CERN Document Server

    Mahboob, Ahmar

    2010-01-01

    The NNEST Lens invites you to imagine how the field of TESOL and applied linguistics can develop if we use the multilingual, multicultural, and multinational perspectives of an NNEST lens to re-examine our assumptions, practices, and theories in the field

  19. Effect of contact lens use on Computer Vision Syndrome.

    Science.gov (United States)

    Tauste, Ana; Ronda, Elena; Molina, María-José; Seguí, Mar

    2016-03-01

    To analyse the relationship between Computer Vision Syndrome (CVS) in computer workers and contact lens use, according to lens materials. Cross-sectional study. The study included 426 civil-service office workers, of whom 22% were contact lens wearers. Workers completed the Computer Vision Syndrome Questionnaire (CVS-Q) and provided information on their contact lenses and exposure to video display terminals (VDT) at work. CVS was defined as a CVS-Q score of 6 or more. The covariates were age and sex. Logistic regression was used to calculate the association (crude and adjusted for age and sex) between CVS and individual and work-related factors, and between CVS and contact lens type. Contact lens wearers are more likely to suffer CVS than non-lens wearers, with a prevalence of 65% vs 50%. Workers who wear contact lenses and are exposed to the computer for more than 6 h day(-1) are more likely to suffer CVS than non-lens wearers working at the computer for the same amount of time (aOR = 4.85; 95% CI, 1.25-18.80; p = 0.02). Regular contact lens use increases CVS after 6 h of computer work. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.

  20. The effect of compliance on contact lens case contamination.

    Science.gov (United States)

    Tilia, Daniel; Lazon de la Jara, Percy; Zhu, Hua; Naduvilath, Thomas J; Holden, Brien A

    2014-03-01

    To determine the efficacy of written instructions on contact lens case hygiene and to quantify the effect of noncompliance on contact lens case contamination. Data were retrospectively analyzed from 16 prospective, 3-month daily-wear studies during which six commercially available silicone hydrogel contact lenses and seven lens care solutions (LCS) were tested following a similar protocol. Verbal instructions regarding case hygiene (rinse case with LCS, not tap water) were given in nine studies, while the same instructions were given verbally and in written format in seven studies. A survey on contact lens, LCS, and lens case hygiene was completed at 1- and 3-month visits and compliance with case hygiene instructions was determined. Regular contact lens cases were used for 1 month and collected for microbial analysis at the 1- and 3-month visits. The rate of case contamination and the types of microbes contaminating cases were evaluated. Participants given verbal and written instructions were more likely to be compliant with case hygiene instructions than those just given verbal instructions (odds ratio [OR]: 2.19, p hygiene can be improved by effective communication of instructions. Contact lens wearers should be actively discouraged from rinsing contact lens cases with tap water because of the increased risk of GNB contamination.