    Science.gov (United States)

    Mangan, Michael A.; Blain, Matthew G.; Tigges, Chris P.; Linker, Kevin L.

    2011-04-19

    An array of microfabricated linear Paul-Straubel ion traps can be used for mass spectrometric applications. Each ion trap comprises two parallel inner RF electrodes and two parallel outer DC control electrodes symmetric about a central trap axis and suspended over an opening in a substrate. Neighboring ion traps in the array can share a common outer DC control electrode. The ions confined transversely by an RF quadrupole electric field potential well on the ion trap axis. The array can trap a wide array of ions.

  2. Miniaturized Linear Wire Ion Trap Mass Analyzer.

    Science.gov (United States)

    Wu, Qinghao; Li, Ailin; Tian, Yuan; Zare, Richard N; Austin, Daniel E

    2016-08-02

    We report a linear ion trap (LIT) in which the electric field is formed by fine wires held under tension and accurately positioned using holes drilled in two end plates made of plastic. The coordinates of the hole positions were optimized in simulation. The stability diagram and mass spectra using boundary ejection were compared between simulation and experiment and good agreement was found. The mass spectra from experiments show peak widths (fwhm) in units of mass-to-charge of around 0.38 Th using a scan rate of 3830 Th/s. The limits of detection are 137 ppbv and 401 ppbv for benzene and toluene, respectively. Different sizes of the wire ion trap can be easily fabricated by drilling holes in scaled positions. Other distinguishing features, such as high ion and photon transmission, low capacitance, high tolerance to mechanical and assembly error, and low weight, are discussed.

  3. Quantitation of isobaric phosphatidylcholine species in human plasma using a hybrid quadrupole linear ion-trap mass spectrometer.

    Science.gov (United States)

    Zacek, Petr; Bukowski, Michael; Rosenberger, Thad A; Picklo, Matthew

    2016-12-01

    Phosphatidylcholine (PC) species in human plasma are used as biomarkers of disease. PC biomarkers are often limited by the inability to separate isobaric PCs. In this work, we developed a targeted shotgun approach for analysis of isobaric and isomeric PCs. This approach is comprised of two MS methods: a precursor ion scanning (PIS) of mass m/z 184 in positive mode (PIS m/z +184) and MS(3) fragmentation in negative mode, both performed on the same instrument, a hybrid triple quadrupole ion-trap mass spectrometer. The MS(3) experiment identified the FA composition and the relative abundance of isobaric and sn-1, sn-2 positional isomeric PC species, which were subsequently combined with absolute quantitative data obtained by PIS m/z +184 scan. This approach was applied to the analysis of a National Institute of Standards and Technology human blood plasma standard reference material (SRM 1950). We quantified more than 70 PCs and confirmed that a majority are present in isobaric and isomeric mixtures. The FA content determined by this method was comparable to that obtained using GC with flame ionization detection, supporting the quantitative nature of this MS method. This methodology will provide more in-depth biomarker information for clinical and mechanistic studies.

  4. Comprehensive lipidome analysis by shotgun lipidomics on a hybrid quadrupole-orbitrap-linear ion trap mass spectrometer.

    Science.gov (United States)

    Almeida, Reinaldo; Pauling, Josch Konstantin; Sokol, Elena; Hannibal-Bach, Hans Kristian; Ejsing, Christer S

    2015-01-01

    Here we report on the application of a novel shotgun lipidomics platform featuring an Orbitrap Fusion mass spectrometer equipped with an automated nanoelectrospray ion source. To assess the performance of the platform for in-depth lipidome analysis, we evaluated various instrument parameters, including its high resolution power unsurpassed by any other contemporary Orbitrap instrumentation, its dynamic quantification range and its efficacy for in-depth structural characterization of molecular lipid species by quadrupole-based higher-energy collisional dissociation (HCD), and ion trap-based resonant-excitation collision-induced dissociation (CID). This evaluation demonstrated that FTMS analysis with a resolution setting of 450,000 allows distinguishing isotopes from different lipid species and features a linear dynamic quantification range of at least four orders of magnitude. Evaluation of fragmentation analysis demonstrated that combined use of HCD and CID yields complementary fragment ions of molecular lipid species. To support global lipidome analysis, we designed a method, termed MS(ALL), featuring high resolution FTMS analysis for lipid quantification, and FTMS(2) analysis using both HCD and CID and ITMS(3) analysis utilizing dual CID for in-depth structural characterization of molecular glycerophospholipid species. The performance of the MS(ALL) method was benchmarked in a comparative analysis of mouse cerebellum and hippocampus. This analysis demonstrated extensive lipidome quantification covering 311 lipid species encompassing 20 lipid classes, and identification of 202 distinct molecular glycerophospholipid species when applying a novel high confidence filtering strategy. The work presented here validates the performance of the Orbitrap Fusion mass spectrometer for in-depth lipidome analysis.

  5. Comprehensive profiling of N-acylhomoserine lactones produced by Yersinia pseudotuberculosis using liquid chromatography coupled to hybrid quadrupole-linear ion trap mass spectrometry.

    Science.gov (United States)

    Ortori, Catharine A; Atkinson, Steve; Chhabra, Siri Ram; Cámara, Miguel; Williams, Paul; Barrett, David A

    2007-01-01

    A method for the comprehensive profiling of the N-acylhomoserine lactone (AHL) family of bacterial quorum-sensing molecules is presented using liquid chromatography (LC) coupled to hybrid quadrupole-linear ion trap (QqQLIT) mass spectrometry. Information-dependent acquisition (IDA), using triggered combinations of triple-quadrupole and linear ion trap modes in the same LC-MS/MS run, was used to simultaneously screen, quantify and identify multiple AHLs in a single sample. This MS method uses common AHL fragment ions attributed to the homoserine moiety and the 3-oxo-, 3-hydroxy- or unsubstituted acyl side chains, to identify unknown AHLs in cell-free culture supernatants in an unbiased manner. This LC-MS technique was applied to determine the relative molar ratios of AHLs produced by Yersinia pseudotuberculosis and the consequences of inactivating by mutation either or both of the AHL synthase genes (ypsI and ytbI) on AHL profile and concentration. The Y. pseudotuberculosis wild type but not the ypsI ytbI double mutant produced at least 24 different AHLs with acyl chains ranging from C4 to C15 with or without 3-oxo or 3-hydroxy substituents. YtbI, in contrast to YpsI, could direct the synthesis of all of the AHLs identified. The most abundant and hence most biologically relevant Y. pseudotuberculosis AHLs were found to be the 3-oxo-substituted C6, C7 and C8 AHLs and the unsubstituted C6 and C8 compounds. The LC-QqQLIT methodology is broadly applicable to quorum-sensing signal molecule analysis and can provide comprehensive AHL profiles and concentrations from a single sample and simultaneously collect confirmatory spectra for each AHL identified.

  6. Comprehensive lipidome analysis by shotgun lipidomics on a hybrid quadrupole-orbitrap-linear ion trap mass spectrometer

    DEFF Research Database (Denmark)

    Almeida, Reinaldo; Pauling, Josch Konstantin; Sokol, Elena

    2015-01-01

    , including its high resolution power unsurpassed by any other contemporary Orbitrap instrumentation, its dynamic quantification range and its efficacy for in-depth structural characterization of molecular lipid species by quadrupole-based higher-energy collisional dissociation (HCD), and ion trap...... of fragmentation analysis demonstrated that combined use of HCD and CID yields complementary fragment ions of molecular lipid species. To support global lipidome analysis, we designed a method, termed MS(ALL), featuring high resolution FTMS analysis for lipid quantification, and FTMS(2) analysis using both HCD...... and CID and ITMS(3) analysis utilizing dual CID for in-depth structural characterization of molecular glycerophospholipid species. The performance of the MS(ALL) method was benchmarked in a comparative analysis of mouse cerebellum and hippocampus. This analysis demonstrated extensive lipidome...

  7. A validated hybrid quadrupole linear ion-trap LC-MS method for the analysis of morphine and morphine glucuronides applied to opiate deaths.

    Science.gov (United States)

    Taylor, Kerry; Elliott, Simon

    2009-05-30

    A hybrid quadrupole linear ion-trap mass spectrometer using an electrospray ionisation ion source coupled to a HPLC system has been used to develop a method which can accurately measure morphine, morphine-3-glucuronide (M3G) and morphine-6-glucuronide (M6G) in plasma, whole blood and post-mortem blood following solid-phase extraction. The method can also qualitatively detect various other opioids and related compounds including: codeine, dihydrocodeine (and metabolites), noscapine, papaverine and 6-acetylmorphine (6-AM). The method has been favourably compared to an existing laboratory method using a now discontinued radio-immunoassay technique. The advantage of measuring the glucuronides directly rather than following deconjugation by beta-glucuronidase has also been shown. Detection and quantification of compounds was achieved using multiple reaction monitoring (MRM) incorporating the use of deuterated morphine and M3G as internal standards. Precision and accuracy was determined to be less than 10% at both high and low levels for all analytes and the calibration curve was deemed linear over an acceptable range. Recovery in blood was greater than 90% and ion suppression/enhancement was shown to be less than 15%. This method was applied to over 130 post-mortem cases involving the use of heroin, prescribed morphine and codeine. The range of concentrations of morphine, M3G and M6G was large (particularly in heroin and prescribed morphine cases), reflecting the many different factors involved with therapeutic use or fatal opiate poisonings, including tolerance associated with regular use, variable dose regimens and co-administration of other drugs. Detection of other constituents of the opium poppy such as noscapine and papaverine and metabolites of diacetylmorphine in the blood (6-AM) was useful in determining the source of the morphine (i.e. illicit heroin) and the rapidity of death after administration.

  8. Differentially pumped dual linear quadrupole ion trap mass spectrometer

    Science.gov (United States)

    Owen, Benjamin C.; Kenttamaa, Hilkka I.

    2015-10-20

    The present disclosure provides a new tandem mass spectrometer and methods of using the same for analyzing charged particles. The differentially pumped dual linear quadrupole ion trap mass spectrometer of the present disclose includes a combination of two linear quadrupole (LQIT) mass spectrometers with differentially pumped vacuum chambers.

  9. Differentially pumped dual linear quadrupole ion trap mass spectrometer

    Science.gov (United States)

    Owen, Benjamin C.; Kenttamaa, Hilkka I.

    2016-11-15

    The present disclosure provides a new tandem mass spectrometer and methods of using the same for analyzing charged particles. The differentially pumped dual linear quadrupole ion trap mass spectrometer of the present disclose includes a combination of two linear quadrupole (LQIT) mass spectrometers with differentially pumped vacuum chambers.

  10. Food contaminant analysis at ultra-high mass resolution: application of hybrid linear ion trap - orbitrap mass spectrometry for the determination of the polyether toxins, azaspiracids, in shellfish.

    LENUS (Irish Health Repository)

    2010-10-30

    The biotoxins, azaspiracids (AZAs), from marine phytoplankton accumulate in shellfish and affect human health by causing severe gastrointestinal disturbance, diarrhea, nausea and vomiting. Specific and sensitive methods have been developed and validated for the determination of the most commonly occurring azaspiracid analogs. An LTQ Orbitrap mass spectrometer is a hybrid instrument that combines linear ion trap (LIT) mass spectrometry (MS) with high-resolution Fourier transform (FT) MS and this was exploited to perform simultaneous ultra-high-resolution full-scan MS analysis and collision-induced dissociation (CID) tandem mass spectrometry (MS\\/MS). Using the highest mass resolution setting (100,000 FWHM) in full-scan mode, the methodology was validated for the determination of six AZAs in mussel (Mytilus galloprovincialis) tissue extracts. Ultra-high mass resolution, together with a narrow mass tolerance window of ±2 mDa, dramatically improved detection sensitivity. In addition to employing chromatographic resolution to distinguish between the isomeric azaspiracid analogs, AZA1\\/AZA6 and AZA4\\/AZA5, higher energy collisionally induced dissociation (HCD) fragmentation on selected precursor ions were performed in parallel with full-scan FTMS. Using HCD MS\\/MS, most precursor and product ion masses were determined within 1 ppm of the theoretical m\\/z values throughout the mass spectral range and this enhanced the reliability of analyte identity.For the analysis of mussels (M. galloprovincialis), the method limit of quantitation (LOQ) was 0.010 µg\\/g using full-scan FTMS and this was comparable with the LOQ (0.007 µg\\/g) using CID MS\\/MS. The repeatability data were; intra-day RSD% (1.8-4.4%; n = 6) and inter-day RSD% (4.7-8.6%; n = 3). Application of these methods to the analysis of mussels (M. edulis) that were naturally contaminated with azaspiracids, using high-resolution full-scan Orbitrap MS and low-resolution CID MS\\/MS, produced

  11. A hybrid liquid chromatography-mass spectrometry strategy in a forensic laboratory for opioid, cocaine and amphetamine classes in human urine using a hybrid linear ion trap-triple quadrupole mass spectrometer.

    Science.gov (United States)

    Dowling, Geraldine; Regan, Liam; Tierney, Julie; Nangle, Michael

    2010-10-29

    A rapid method has been developed to analyse morphine, codeine, morphine-3-glucuronide, 6-monoacetylmorphine, cocaine, benzoylegonine, buprenorphine, dihydrocodeine, cocaethylene, 3,4-methylenedioxyamphetamine, ketamine, 3,4-methylenedioxymethamphetamine, pseudoephedrine, lignocaine, benzylpiperazine, methamphetamine, amphetamine, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine and methadone in human urine. Urine samples were diluted with methanol:water (1:1, v/v) and sample aliquots were analysed by hybrid linear ion trap-triple quadrupole mass spectrometry with a runtime of 12.5 min. Multiple reaction monitoring (MRM) as survey scan and an enhanced product ion (EPI) scan as dependent scan were performed in an information-dependent acquisition (IDA) experiment. Finally, drug identification and confirmation was carried out by library search with a developed in-house MS/MS library based on EPI spectra at a collision energy spread of 35±15 in positive mode and MRM ratios. The method was validated in urine, according to the criteria defined in Commission Decision 2002/657/EC. At least two MRM transitions for each substance were monitored in addition to EPI spectra and deuterated analytes were used as internal standards for quantitation. The reporting level was 0.05 μg mL(-1) for the range of analytes tested. The regression coefficients (r(2)) for the calibration curves (0-4 μg mL(-1)) in the study were ≥0.98. The method proved to be simple and time efficient and was implemented as an analytical strategy for the illicit drug monitoring of opioids, cocaines and amphetamines in criminal samples from crime offenders, abusers or victims in the Republic of Ireland. To the best of our knowledge there are no hybrid LC-MS applications using MRM mode and product ion spectra in the linear ion trap mode for opioids, cocaines or amphetamines with validation data in urine.

  12. A Linear RFQ Ion Trap for the Enriched Xenon Observatory

    Energy Technology Data Exchange (ETDEWEB)

    Flatt, B.; Green, M.; Wodin, J.; DeVoe, R.; Fierlinger, P.; Gratta, G.; LePort, F.; Montero Diez, M.; Neilson, R.; O' Sullivan, K.; Pocar, A.; Baussan, E.; Breidenbach, M.; Conley, R.; Fairbank Jr., W.; Farine, J.; Hall, K.; Hallman, D.; Hargrove, C.; Hauger, M.; Hodgson, J.; /Stanford U., Phys. Dept. /Neuchatel U. /SLAC /Colorado State U. /Laurentian U. /Carleton U. /Alabama U.

    2008-01-14

    The design, construction, and performance of a linear radio-frequency ion trap (RFQ) intended for use in the Enriched Xenon Observatory (EXO) are described. EXO aims to detect the neutrinoless double-beta decay of {sup 136}Xe to {sup 136}Ba. To suppress possible backgrounds EXO will complement the measurement of decay energy and, to some extent, topology of candidate events in a Xe filled detector with the identification of the daughter nucleus ({sup 136}Ba). The ion trap described here is capable of accepting, cooling, and confining individual Ba ions extracted from the site of the candidate double-beta decay event. A single trapped ion can then be identified, with a large signal-to-noise ratio, via laser spectroscopy.

  13. Evaluation of multiple reaction monitoring cubed for the analysis of tachykinin related peptides in rat spinal cord using a hybrid triple quadrupole-linear ion trap mass spectrometer.

    Science.gov (United States)

    Pailleux, Floriane; Beaudry, Francis

    2014-02-01

    Targeted peptide methods generally use HPLC-MS/MRM approaches. Although dependent on the instrumental resolution, interferences may occur while performing analysis of complex biological matrices. HPLC-MS/MRM(3) is a technique, which provides a significantly better selectivity, compared with HPLC-MS/MRM assay. HPLC-MS/MRM(3) allows the detection and quantitation by enriching standard MRM with secondary product ions that are generated within the linear ion trap. Substance P (SP) and neurokinin A (NKA) are tachykinin peptides playing a central role in pain transmission. The objective of this study was to verify whether HPLC-MS/MRM(3) could provide significant advantages over a more traditional HPLC-MS/MRM assay for the quantification of SP and NKA in rat spinal cord. The results suggest that reconstructed MRM(3) chromatograms display significant improvements with the nearly complete elimination of interfering peaks but the sensitivity (i.e. signal-to-noise ratio) was severely reduced. The precision (%CV) observed was between 3.5% and 24.1% using HPLC-MS/MRM and in the range of 4.3-13.1% with HPLC-MS/MRM(3), for SP and NKA. The observed accuracy was within 10% of the theoretical concentrations tested. HPLC-MS/MRM(3) may improve the assay sensitivity to detect difference between samples by reducing significantly the potential of interferences and therefore reduce instrumental errors.

  14. Linear ion trap imperfection and the compensation of excess micromotion

    Institute of Scientific and Technical Information of China (English)

    Xie Yi; Wan Wei; Zhou Fei; Chen Liang; Li Chao-Hong; Feng Mang

    2012-01-01

    Quantum computing requires ultracold ions in a ground vibrational state,which is achieved by sideband cooling.We report our recent efforts towards the Lamb-Dicke regime which is a prerequisite of sideband cooling.We first analyse the possible imperfection in our linear ion trap setup and then demonstrate how to suppress the imperfection by compensating the excess micromotion of the ions.The ions,after the micromotion compensation,are estimated to be very close to the Doppler-cooling limit.

  15. Screening of drugs and toxic compounds with liquid chromatography-linear ion trap tandem mass spectrometry.

    Science.gov (United States)

    Sauvage, François-Ludovic; Saint-Marcoux, Franck; Duretz, Bénédicte; Deporte, Didier; Lachatre, Gérard; Marquet, Pierre

    2006-09-01

    In clinical and forensic toxicology, general unknown screening is used to detect and identify exogenous compounds. In this study, we aimed to develop a comprehensive general unknown screening method based on liquid chromatography coupled with a hybrid triple-quadrupole linear ion trap mass spectrometer. After solid-phase extraction, separation was performed using gradient reversed-phase chromatography. The mass spectrometer was operated in the information-dependent acquisition mode, switching between a survey scan acquired in the Enhanced Mass Spectrometry mode with dynamic subtraction of background noise and a dependent scan obtained in the enhanced product ion scan mode. The complete cycle time was 1.36 s. A library of 1000 enhanced product ion-tandem mass spectrometry spectra in positive mode and 250 in negative mode, generated using 3 alternated collision tensions during each scan, was created by injecting pure solutions of drugs and toxic compounds. Comparison with HPLC-diode array detection and gas chromatography-mass spectrometry for the analysis of 36 clinical samples showed that linear ion trap tandem mass spectrometry could identify most of the compounds (94% of the total). Some compounds were detected only by 1 of the other 2 techniques. Specific clinical cases highlighted the advantages and limitations of the method. A unique combination of new operating modes provided by hybrid triple-quadrupole linear ion trap mass spectrometers and new software features allowed development of a comprehensive and efficient method for the general unknown screening of drugs and toxic compounds in blood or urine.

  16. Non-target screening of Allura Red AC photodegradation products in a beverage through ultra high performance liquid chromatography coupled with hybrid triple quadrupole/linear ion trap mass spectrometry.

    Science.gov (United States)

    Gosetti, Fabio; Chiuminatto, Ugo; Mazzucco, Eleonora; Calabrese, Giorgio; Gennaro, Maria Carla; Marengo, Emilio

    2013-01-15

    The study deals with the identification of the degradation products formed by simulated sunlight photoirradiation in a commercial beverage that contains Allura Red AC dye. An UHPLC-MS/MS method, that makes use of hybrid triple quadrupole/linear ion trap, was developed. In the identification step the software tool information dependent acquisition (IDA) was used to automatically obtain information about the species present and to build a multiple reaction monitoring (MRM) method with the MS/MS fragmentation pattern of the species considered. The results indicate that the identified degradation products are formed from side-reactions and/or interactions among the dye and other ingredients present in the beverage (ascorbic acid, citric acid, sucrose, aromas, strawberry juice, and extract of chamomile flowers). The presence of aromatic amine or amide functionalities in the chemical structures proposed for the degradation products might suggest potential hazards to consumer health.

  17. Linear Ion Trap for the Mars Organic Molecule Analyzer

    Science.gov (United States)

    Brinckerhoff, William; Arevalo, Ricardo; Danell, Ryan; van Amerom, Friso; Pinnick, Veronica; Li, Xiang; Hovmand, Lars; Getty, Stephanie; Mahaffy, Paul; Goesmann, Fred; Steininger, Harald

    2014-05-01

    The 2018 ExoMars rover mission includes the Mars Organic Molecule Analyzer (MOMA) investigation. MOMA will examine the chemical composition of samples acquired from depths of up to two meters below the martian surface, where organics may be protected from radiative and oxidative degradation. When combined with the complement of instruments in the rover's Pasteur Payload, MOMA has the potential to reveal the presence of a wide range of organics preserved in a variety of mineralogical environments, and to begin to understand the structural character and potential origin of those compounds. MOMA includes a linear, or 2D, ion trap mass spectrometer (ITMS) that is designed to analyze molecular composition of (i) gas evolved from pyrolyzed powder samples and separated on a gas chromatograph and (ii) ions directly desorbed from solid samples at Mars ambient pressure using a pulsed laser and a fast-valve capillary ion inlet system. This "dual source" approach gives MOMA unprecedented breadth of detection over a wide range of molecular weights and volatilities. Analysis of nonvolatile, higher-molecular weight organics such as carboxylic acids and peptides even in the presence of significant perchlorate concentrations is enabled by the extremely short (~1 ns) pulses of the desorption laser. Use of the ion trap's tandem mass spectrometry mode permits selective focus on key species for isolation and controlled fragmentation, providing structural analysis capabilities. The flight-like engineering test unit (ETU) of the ITMS, now under construction, will be used to verify breadboard performance with high fidelity, while simultaneously supporting the development of analytical scripts and spectral libraries using synthetic and natural Mars analog samples guided by current results from MSL. ETU campaign data will strongly advise the specifics of the calibration applied to the MOMA flight model as well as the science operational procedures during the mission.

  18. A hand-portable digital linear ion trap mass spectrometer.

    Science.gov (United States)

    Xue, Bing; Sun, Lulu; Huang, Zhengxu; Gao, Wei; Fan, Rongrong; Cheng, Ping; Ding, Li; Ma, Li; Zhou, Zhen

    2016-10-07

    A hand-portable digital linear ion trap mass spectrometer (DLIT-MS) has been developed for VOC analysis. It has a weight of 18 kg with dimensions of 49 cm × 39 cm × 16 cm, and consumes an average power of ca. 60 W. As a result of the introduction of a digital waveform, the DLIT-MS can be driven at a lower voltage (±100 V) to cover a mass range of 30-300 Th with a unit resolution. Compact electronics has been designed to control the DLIT-MS and record mass spectra. The mass drift was reduced after the improvement in electronics to stabilize the digital waveform voltage during the mass scan. Tandem mass spectrometry (MS) has been achieved by using digital asymmetric waveform isolation (DAWI), forward and reverse scan, and collision induced dissociation (CID). The isolation and CID efficiency for methyl salicylate were 83.9% and 81.3%, respectively. A novel buffer gas inlet system was designed to enhance the sensitivity and allow easy and safe use of the instrument. Limits of detection below 1 ppbv were obtained for several mixed gaseous samples.

  19. Characterization and identification of the chemical constituents from tartary buckwheat (Fagopyrum tataricum Gaertn) by high performance liquid chromatography/photodiode array detector/linear ion trap FTICR hybrid mass spectrometry.

    Science.gov (United States)

    Ren, Qiang; Wu, Caisheng; Ren, Yan; Zhang, Jinlan

    2013-02-15

    In recent years tartary buckwheat has become popular healthful food due to its antioxidant, antidiabetic and antitumor activities. However, its chemical constituents have not yet been fully characterized and identified. In this paper, a novel high performance liquid chromatography coupled with photodiode array detector and linear ion trap FTICR hybrid mass spectrometry (HPLC-PDA/LTQ-FTICRMS) method was established to characterize and identify a total of 36 compounds by a single run. The retention time, maximum UV absorption wavelength, accurate mass weight and characteristic fragment ions were collected on line. To confirm the structures, 11 compounds were isolated and identified by MS and NMR experiments. 1, 3, 6, 6'-tetra-feruloyl sucrose named taroside was a new phenlypropanoid glycoside, together with 3, 6-di-p-coumaroyl-1, 6'-di-feruloyl sucrose, 1, 6, 6'-tri-feruloyl-3-p-coumaroyl sucrose, N-trans-feruloyltyramine and quercetin-3-O-[β-D-xyloxyl-(1→2)-α-L-rhamnoside] were isolated for the first time from the Fagopyrum species. The research enriched the chemical information of tartary buckwheat.

  20. Reducing Space Charge Effects in a Linear Ion Trap by Rhombic Ion Excitation and Ejection

    Science.gov (United States)

    Zhang, Xiaohua; Wang, Yuzhuo; Hu, Lili; Guo, Dan; Fang, Xiang; Zhou, Mingfei; Xu, Wei

    2016-07-01

    Space charge effects play important roles in ion trap operations, which typically limit the ion trapping capacity, dynamic range, mass accuracy, and resolving power of a quadrupole ion trap. In this study, a rhombic ion excitation and ejection method was proposed to minimize space charge effects in a linear ion trap. Instead of applying a single dipolar AC excitation signal, two dipolar AC excitation signals with the same frequency and amplitude but 90° phase difference were applied in the x- and y-directions of the linear ion trap, respectively. As a result, mass selective excited ions would circle around the ion cloud located at the center of the ion trap, rather than go through the ion cloud. In this work, excited ions were then axially ejected and detected, but this rhombic ion excitation method could also be applied to linear ion traps with ion radial ejection capabilities. Experiments show that space charge induced mass resolution degradation and mass shift could be alleviated with this method. For the experimental conditions in this work, space charge induced mass shift could be decreased by ~50%, and the mass resolving power could be improved by ~2 times at the same time.

  1. Rapid screening of drugs of abuse in human urine by high-performance liquid chromatography coupled with high resolution and high mass accuracy hybrid linear ion trap-Orbitrap mass spectrometry.

    Science.gov (United States)

    Li, Xiaowen; Shen, Baohua; Jiang, Zheng; Huang, Yi; Zhuo, Xianyi

    2013-08-09

    A novel analytical toxicology method has been developed for the analysis of drugs of abuse in human urine by using a high resolution and high mass accuracy hybrid linear ion trap-Orbitrap mass spectrometer (LTQ-Orbitrap-MS). This method allows for the detection of different drugs of abuse, including amphetamines, cocaine, opiate alkaloids, cannabinoids, hallucinogens and their metabolites. After solid-phase extraction with Oasis HLB cartridges, spiked urine samples were analysed by HPLC/LTQ-Orbitrap-MS using an electrospray interface in positive ionisation mode, with resolving power of 30,000 full width at half maximum (FWHM). Gradient elution off of a Hypersil Gold PFP column (50mm×2.1mm) allowed to resolve 65 target compounds and 3 internal standards in a total chromatographic run time of 20min. Validation of this method consisted of confirmation of identity, selectivity, linearity, limit of detection (LOD), lowest limits of quantification (LLOQ), accuracy, precision, extraction recovery and matrix effect. The regression coefficients (r(2)) for the calibration curves (LLOQ - 100ng/mL) in the study were ≥0.99. The LODs for 65 validated compounds were better than 5ng/ml except for 4 compounds. The relative standard deviation (RSD), which was used to estimate repeatability at three concentrations, was always less than 15%. The recovery of extraction and matrix effects were above 50 and 70%, respectively. Mass accuracy was always better than 2ppm, corresponding to a maximum mass error of 0.8 millimass units (mmu). The accurate masses of characteristic fragments were obtained by collisional experiments for a more reliable identification of the analytes. Automated data analysis and reporting were performed using ToxID software with an exact mass database. This procedure was then successfully applied to analyse drugs of abuse in a real urine sample from subject who was assumed to be drug addict.

  2. Simultaneous determination of triazine herbicides in rice by high-performance liquid chromatography coupled with high resolution and high mass accuracy hybrid linear ion trap-orbitrap mass spectrometry.

    Science.gov (United States)

    Mou, Ren-Xiang; Chen, Ming-Xue; Cao, Zhao-Yun; Zhu, Zhi-Wei

    2011-11-07

    A method was developed for the simultaneous determination of 10 triazine herbicides (cyanazine, simazine, simetryn, metribuzin, atrazine, ametryn, terbuthylazine, prometryn, terbutryn, and dimethametryn) in rice samples by high resolution and high mass accuracy hybrid linear ion trap-Orbitrap mass spectrometer. After extraction with acetonitrile and evaporation, the herbicides were redissolved in n-hexane and purified on a Florisil solid-phase extraction column. All compounds were separated within 12 min, producing more than 11 data points for each herbicide and high mass accuracy quantified ions which the mass errors of absolute value were less than 1.9 ppm in pure solution and 2.1 ppm in the matrix-matched standards solution. The method was validated in terms of the limits of detection and the limits of quantification. The linearity was satisfactory, with a correlation coefficient of >0.9975. Precision and recovery studies were evaluated at three concentration levels for Japonica, Indica, and Glutinous rice matrix. The mean recoveries obtained for all analytes in spiked Xiushui 03, Liangyoupeijiu, and Taihunuo rice samples were 83.3-99.0%, 82.0-99.7%, and 84.2-99.4%, respectively, with relative standard deviation in range 1.7-10.6%, 1.2-10.7%, and 1.9-11.6% for spiked rice samples, respectively. The intra-day precision (n=5) for the 10 herbicides in rice samples spiked at an intermediate level was between 2.8% and 7.9%, and the inter-day precision over 10 days (n=10) was between 5.5% and 15.9%.

  3. Comparison of triple quadrupole, hybrid linear ion trap triple quadrupole, time-of-flight and LTQ-Orbitrap mass spectrometers in drug discovery phase metabolite screening and identification in vitro--amitriptyline and verapamil as model compounds.

    Science.gov (United States)

    Rousu, Timo; Herttuainen, Jukka; Tolonen, Ari

    2010-04-15

    Liquid chromatography in combination with mass spectrometry (LC/MS) is a superior analytical technique for metabolite profiling and identification studies performed in drug discovery and development laboratories. In the early phase of drug discovery the analytical approach should be both time- and cost-effective, thus providing as much data as possible with only one visit to the laboratory, without the need for further experiments. Recent developments in mass spectrometers have created a situation where many different mass spectrometers are available for the task, each with their specific strengths and drawbacks. We compared the metabolite screening properties of four main types of mass spectrometers used in analytical laboratories, considering both the ability to detect the metabolites and provide structural information, as well as the issues related to time consumption in laboratory and thereafter in data processing. Human liver microsomal incubations with amitriptyline and verapamil were used as test samples, and early-phase 'one lab visit only' approaches were used with all instruments. In total, 28 amitriptyline and 69 verapamil metabolites were found and tentatively identified. Time-of-flight mass spectrometry (TOFMS) was the only approach detecting all of them, shown to be the most suitable instrument for elucidating as comprehensive metabolite profile as possible leading also to lowest overall time consumption together with the LTQ-Orbitrap approach. The latter however suffered from lower detection sensitivity and false negatives, and due to slow data acquisition rate required slower chromatography. Approaches with triple quadrupole mass spectrometry (QqQ) and hybrid linear ion trap triple quadrupole mass spectrometry (Q-Trap) provided the highest amount of fragment ion data for structural elucidation, but, in addition to being unable to produce very high-important accurate mass data, they suffered from many false negatives, and especially with the Qq

  4. Cryogenic Linear Ion Trap for Large-Scale Quantum Simulations

    Science.gov (United States)

    Pagano, Guido; Hess, Paul; Kaplan, Harvey; Birckelbaw, Eric; Hernanez, Micah; Lee, Aaron; Smith, Jake; Zhang, Jiehang; Monroe, Christopher

    2016-05-01

    Ions confined in RF Paul traps are a useful tool for quantum simulation of long-range spin-spin interaction models. As the system size increases, classical simulation methods become incapable of modeling the exponentially growing Hilbert space, necessitating quantum simulation for precise predictions. Current experiments are limited to less than 30 qubits due to collisions with background gas that regularly destroys the ion crystal. We present progress toward the construction of a cryogenic ion trap apparatus, which uses differential cryopumping to reduce vacuum pressure to a level where collisions do not occur. This should allow robust trapping of about 100 ions/qubits in a single chain with long lifetimes. Such a long chain will provide a platform to investigate simultaneously cooling of various vibrational modes and will enable quantum simulations that outperform their classical counterpart. Our apparatus will provide a powerful test-bed to investigate a large variety of Hamiltonians, including spin 1 and spin 1/2 systems with Ising or XY interactions. This work is supported by the ARO Atomic Physics Program, the AFOSR MURI on Quantum Measurement and Verification, the IC Fellowship Program and the NSF Physics Frontier Center at JQI.

  5. CID of singly charged antioxidants applied in lubricants by means of a 3D ion trap and a linear ion trap-Orbitrap mass spectrometer.

    Science.gov (United States)

    Kassler, Alexander; Pittenauer, Ernst; Doerr, Nicole; Allmaier, Guenter

    2011-06-01

    The aim of this study was to investigate the fragmentation behavior induced by low-energy collision-induced dissociation (LE-CID) of four selected antioxidants applied in lubricants, by two different types of ion trap mass spectrometers: a three-dimensional ion trap (3D-IT) and a linear IT (LIT) Orbitrap MS. Two sterically hindered phenols and two aromatic amines were selected as model compounds representing different antioxidant classes and were characterized by positive-ion electrospray ionization (ESI) and LE-CID. Various types of molecular ions (e.g. [M](+•) , [M + H](+) , [M + NH(4) ](+) or [M + Na](+) ) were used as precursor ions generating a significant number of structurally relevant product ions. Furthermore, the phenolic compounds were analyzed by negative-ion ESI. For both IT types applied for fragmentation, the antioxidants exhibited the same unusual LE-CID behavior: (1) they formed stable radical product ions and (2) CC bond cleavages of aliphatic substituents were observed and their respective cleavage sites depended on the precursor ion selected. This fragmentation provided information on the type of structural isomer usually not obtainable for branched aliphatic substituents utilizing LE-CID. Comparing the two instruments, the main benefit of applying the LIT-Orbitrap was direct access to elemental composition of product ions enabling unambiguous interpretation of fragmentation trees not obtainable by the 3D-IT device (e.g. loss of isobaric neutrals). It should be emphasized that the types of product ions formed do not depend on the type of IT analyzer applied. For characterizing degradation products of antioxidants, the LIT-Orbitrap hybrid system, allowing the determination of accurate m/z values for product ions, is the method of choice.

  6. Performance of the linear ion trap Orbitrap mass analyzer for qualitative and quantitative analysis of drugs of abuse and relevant metabolites in sewage water

    NARCIS (Netherlands)

    Bijlsma, L.; Emke, E.; Hernández, F.; de Voogt, P.

    2013-01-01

    This work illustrates the potential of liquid chromatography coupled to a hybrid linear ion trap Fourier Transform Orbitrap mass spectrometer for the simultaneous identification and quantification of 24 drugs of abuse and relevant metabolites in sewage water. The developed methodology consisted of a

  7. A new ion mobility-linear ion trap instrument for complex mixture analysis.

    Science.gov (United States)

    Donohoe, Gregory C; Maleki, Hossein; Arndt, James R; Khakinejad, Mahdiar; Yi, Jinghai; McBride, Carroll; Nurkiewicz, Timothy R; Valentine, Stephen J

    2014-08-19

    A new instrument that couples a low-pressure drift tube with a linear ion trap mass spectrometer is demonstrated for complex mixture analysis. The combination of the low-pressure separation with the ion trapping capabilities provides several benefits for complex mixture analysis. These include high sensitivity, unique ion fragmentation capabilities, and high reproducibility. Even though the gas-phase separation and the mass measurement steps are each conducted in an ion filtering mode, detection limits for mobility-selected peptide ions are in the tens of attomole range. In addition to ion separation, the low-pressure drift tube can be used as an ion fragmentation cell yielding mobility-resolved fragment ions that can be subsequently analyzed by multistage tandem mass spectrometry (MS(n)) methods in the ion trap. Because of the ion trap configuration, these methods can be comprised of any number (limited by ion signal) of collision-induced dissociation (CID) and electron transfer dissociation (ETD) processes. The high reproducibility of the gas-phase separation allows for comparison of two-dimensional ion mobility spectrometry (IMS)-MS data sets in a pixel-by-pixel fashion without the need for data set alignment. These advantages are presented in model analyses representing mixtures encountered in proteomics and metabolomics experiments.

  8. Ultra-high performance liquid chromatography with linear ion trap-Orbitrap hybrid mass spectrometry combined with a systematic strategy based on fragment ions for the rapid separation and characterization of components in Stellera chamaejasme extracts.

    Science.gov (United States)

    Wang, Zhixin; Qu, Yang; Wang, Li; Zhang, Xiaozhe; Xiao, Hongbin

    2016-04-01

    Stellera chamaejasme, a famous toxic herb, has been used in traditional Chinese medicine to treat various diseases. For decades, increasing attention in modern pharmacological studies has been drawn to S. chamaejasme because of its potential anti-tumor, anti-virus, and anti-fungus activities. However, due to the intrinsic complexity of chemical constitutes, hardly any investigations formed an overall recognition for the chemical profiles of this herb. In this study, a rapid and sensitive ultra-high performance liquid chromatography coupled with linear ion trap-Orbitrap mass spectrometry method was developed to characterize the chemical components of S. chamaejasme extracts. Based on optimized ultra-high performance liquid chromatography and mass spectrometry conditions and systematic fragment ions-based strategy, a total of 47 components including flavones, diterpenes, coumarins, and lignans were simultaneously detected and identified or tentatively identified for the first time. The MS(n) fragmentation patterns of all the characterized compounds in positive or negative electrospray ionization modes were also explored and summarized. These results provided essential data for further pharmacological research on S. chamaejasme. Moreover, the method was demonstrated to be an efficient tool for rapid qualitative analysis of secondary metabolites from natural resources.

  9. Multisectional linear ion trap and novel loading method for optical spectroscopy of electron and nuclear transitions.

    Science.gov (United States)

    Sysoev, Alexey A; Troyan, Victor I; Borisyuk, Peter V; Krasavin, Andrey V; Vasiliev, Oleg S; Palchikov, Vitaly G; Avdeev, Ivan A; Chernyshev, Denis M; Poteshin, Sergey S

    2015-01-01

    There is a growing need for the development of atomic and nuclear frequency standards because of the important contribution of methods for precision time and frequency measurements to the development of fundamental science, technology, and the economy. It is also conditioned by their potential use in optical clocks and quantum logic applications. It is especially important to develop a universal method that could allow one to use ions of most elements effectively (including ones that are not easily evaporated) proposed for the above-mentioned applications. A linear quadrupole ion trap for the optical spectroscopy of electron and nuclear transitions has been developed and evaluated experimentally. An ion source construction is based on an ultra-high vacuum evaporator in which a metal sample is subjected to an electron beam of energy up to 1 keV, resulting in the appearance of gaseous atoms and ions of various charge state. The linear ion trap consists of five successive quadrupole sections including an entrance quadrupole section, quadrupole mass filter, quadrupole ion guide, ion-trap section, and exit quadrupole section. The same radiofrequency but a different direct current voltage feeds the quadrupole sections. The instrument allows the mass and energy selected trapping of ions from ion beams of various intensities and their localization in the area of laser irradiation. The preliminary results presented show that the proposed instrument and methods allow one to produce effectively up to triply charged thorium ions as well as to trap ions for future spectroscopic study. The instrument is proposed for future use in optical clocks and quantum logic application development.

  10. Rapid, high performance method for the determination of vitamin K(1), menaquinone-4 and vitamin K(1) 2,3-epoxide in human serum and plasma using liquid chromatography-hybrid quadrupole linear ion trap mass spectrometry.

    Science.gov (United States)

    Gentili, Alessandra; Cafolla, Arturo; Gasperi, Tecla; Bellante, Simona; Caretti, Fulvia; Curini, Roberta; Fernández, Virginia Pérez

    2014-04-18

    Unlike the other fat-soluble vitamins, vitamin K circulates in the human bloodstream at very low levels because of a low intake in the diet. Mammals have developed an efficient recycling system, known as vitamin K-epoxide cycle, which involve quinone, hydroquinone and epoxide forms of the vitamin. Phylloquinone (K(1)) is the main homologue, while menaquinone-4 (MK-4) is both a member of the vitamin K(2) family and metabolite of K(1) in extra-hepatic tissues. Notwithstanding the recent advances, many aspects of the complex vitamin K physiology still remain to be investigated. Therefore, there is a critical need to develop more reliable analytical methods for determining the vitamin K and its metabolites in biological fluids and tissues. Nevertheless, relatively low concentrations, unavailability of some authentic standards and occurrence of interfering lipids make this a challenging task. The method proposed in the present paper can directly and accurately estimate K(1), K(1) 2,3-epoxide (K(1)O), and MK-4 in human serum and plasma at concentrations in the ng/L-μg/L range, using labelled internal standards and a quadrupole linear ion trap instrument operated in multiple reaction monitoring (MRM) mode. High sensitivity was achieved by removing signal "endogenous suppressors" and making the composition of the non-aqueous mobile phase suitable to support the positive atmospheric pressure chemical ionization of the analytes. An excellent selectivity resulted from the combination of some factors: the MRM acquisition, the adoption of an identification point system, an extraction optimized to remove most of the lipids and a tandem-C18 column-system necessary to separate isobaric interferences from analytes. The method was validated according to the Food and Drug Administration (FDA) guidelines and its accuracy was assessed by analysing 9 samples from the Vitamin K External Quality Assessment Scheme (KEQAS). Its feasibility in evaluating vitamin K status in human serum was

  11. Linear mass scans in quadrupole ion traps using the inverse Mathieu q scan.

    Science.gov (United States)

    Snyder, Dalton T; Pulliam, Christopher J; Cooks, R Graham

    2016-11-30

    Secular frequency scanning is a method of mass selectively scanning ions out of a quadrupole ion trap by linearly ramping the frequency of the resonance ejection signal through ion secular frequencies at constant rf amplitude and frequency. The method is electronically much simpler than resonance ejection but it requires a complex nonlinear calibration procedure to correlate mass-to-charge with time. A method of secular frequency scanning in quadrupole ion traps is described in which mass-to-charge is linear with time. This method, termed an "inverse Mathieu q scan", contrasts with linear frequency sweeping which requires a complex nonlinear mass calibration procedure. In the current method, mass scans are forced to be linear with time by scanning the frequency of the supplementary ac so that there is an inverse relationship between the ejected ion's Mathieu q parameter and time. In all cases, excellent mass spectral linearity is observed. The rf amplitude is shown to control both the scan range and the scan rate, whereas the ac amplitude and scan rate influence the mass resolution. The scan rate depends linearly on the rf amplitude, a unique feature of this scan. Although changes in either rf or ac amplitude affect the positions of peaks in time, they do not change the mass calibration procedure since this only requires a simple linear fit of m/z vs time. Space charge effects are shown to give rise to significant changes in resolution as well as to mass shifts. A method of secular frequency scanning which provides a linear mass scale has been demonstrated. The inverse Mathieu q scan offers a significant increase in mass range and power savings while maintaining access to linearity, paving the way for a mass spectrometer based completely on ac waveforms for ion isolation, ion activation, and ion ejection. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  12. Performance of the linear ion trap Orbitrap mass analyzer for qualitative and quantitative analysis of drugs of abuse and relevant metabolites in sewage water

    OpenAIRE

    Bijlsma, Lubertus; Emke, Erik; Hernández Hernández, Félix; Voogt, Pim de

    2013-01-01

    This work illustrates the potential of liquid chromatography coupled to a hybrid linear ion trap Fourier Transform Orbitrap mass spectrometer for the simultaneous identification and quantification of 24 drugs of abuse and relevant metabolites in sewage water. The developed methodology consisted of automatic solid-phase extraction using Oasis HLB cartridges, chromatographic separation of the targeted drugs, full-scan accurate mass data acquisition under positive electrospray ionization mode ov...

  13. A Linear Ion Trap with an Expanded Inscribed Diameter to Improve Optical Access for Fluorescence Spectroscopy

    Science.gov (United States)

    Rajagopal, Vaishnavi; Stokes, Chris; Ferzoco, Alessandra

    2017-08-01

    We report a custom-geometry linear ion trap designed for fluorescence spectroscopy of gas-phase ions at ambient to cryogenic temperatures. Laser-induced fluorescence from trapped ions is collected from between the trapping rods, orthogonal to the excitation laser that runs along the axis of the linear ion trap. To increase optical access to the ion cloud, the diameter of the round trapping rods is 80% of the inscribed diameter, rather than the roughly 110% used to approximate purely quadrupolar electric fields. To encompass as much of the ion cloud as possible, the first collection optic has a 25.4 mm diameter and a numerical aperture of 0.6. The choice of geometry and collection optics yields 107 detected photons/s from trapped rhodamine 6G ions. The trap is coupled to a closed-cycle helium refrigerator, which in combination with two 50 Ohm heaters enables temperature control to below 25 K on the rod electrodes. The purpose of the instrument is to broaden the applicability of fluorescence spectroscopy of gas-phase ions to cases where photon emission is a minority relaxation pathway. Such studies are important to understand how the microenvironment of a chromophore influences excited state charge transfer processes. [Figure not available: see fulltext.

  14. A Miniaturized Linear Wire Ion Trap with Electron Ionization and Single Photon Ionization Sources

    Science.gov (United States)

    Wu, Qinghao; Tian, Yuan; Li, Ailin; Andrews, Derek; Hawkins, Aaron R.; Austin, Daniel E.

    2017-05-01

    A linear wire ion trap (LWIT) with both electron ionization (EI) and single photon ionization (SPI) sources was built. The SPI was provided by a vacuum ultraviolet (VUV) lamp with the ability to softly ionize organic compounds. The VUV lamp was driven by a pulse amplifier, which was controlled by a pulse generator, to avoid the detection of photons during ion detection. Sample gas was introduced through a leak valve, and the pressure in the system is shown to affect the signal-to-noise ratio and resolving power. Under optimized conditions, the limit of detection (LOD) for benzene was 80 ppbv using SPI, better than the LOD using EI (137 ppbv). System performance was demonstrated by distinguishing compounds in different classes from gasoline.

  15. Laser-induced acoustic desorption coupled with a linear quadrupole ion trap mass spectrometer.

    Science.gov (United States)

    Habicht, Steven C; Amundson, Lucas M; Duan, Penggao; Vinueza, Nelson R; Kenttämaa, Hilkka I

    2010-01-15

    In recent years, laser-induced acoustic desorption (LIAD) coupled with a Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer has been demonstrated to provide a valuable technique for the analysis of a wide variety of nonvolatile, thermally labile compounds, including analytes that could not previously be analyzed by mass spectrometry. Although FT-ICR instruments are very powerful, they are also large and expensive and, hence, mainly used as research instruments. In contrast, linear quadrupole ion trap (LQIT) mass spectrometers are common due to several qualities that make these instruments attractive for both academic and industrial settings, such as high sensitivity, large dynamic range, and experimental versatility. Further, the relatively small size of the instruments, comparatively low cost, and the lack of a magnetic field provide some distinct advantages over FT-ICR instruments. Hence, we have coupled the LIAD technique with a commercial LQIT, the Thermo Fischer Scientific LTQ mass spectrometer. The LQIT was modified for a LIAD probe by outfitting the removable back plate of the instrument with a 6 in. ConFlat flange (CFF) port, gate valve, and sample lock. Reagent ions were created using the LQIT's atmospheric pressure ionization source and trapped in the mass analyzer for up to 10 s to allow chemical ionization reactions with the neutral molecules desorbed via LIAD. These initial experiments focused on demonstrating the feasibility of performing LIAD in the LQIT. Hence, the results are compared to those obtained using an FT-ICR mass spectrometer. Despite the lower efficiency in the transfer of desorbed neutral molecules into the ion trap, and the smaller maximum number of available laser pulses, the intrinsically higher sensitivity of the LQIT resulted in a higher sensitivity relative to the FT-ICR.

  16. A dense gas of laser-cooled atoms for hybrid atom-ion trapping

    Science.gov (United States)

    Höltkemeier, Bastian; Glässel, Julian; López-Carrera, Henry; Weidemüller, Matthias

    2017-01-01

    We describe the realization of a dark spontaneous-force trap of rubidium atoms. The atoms are loaded from a beam provided by a two-dimensional magneto-optical trap yielding a capture efficiency of 75%. The dense and cold atomic sample is characterized by saturated absorption imaging. Up to 10^9 atoms are captured with a loading rate of 3× 10^9 atoms/s into a cloud at a temperature of 250 μK with the density exceeding 10^{11} atoms/cm^3. Under steady-state conditions, more than 90% of the atoms can be prepared into the absolute atomic ground state, which provides favorable conditions for the investigation of sympathetic cooling of ions in a hybrid atom-ion trap.

  17. Infrared ion spectroscopy inside a mass-selective cryogenic 2D linear ion trap.

    Science.gov (United States)

    Cismesia, Adam P; Tesler, Larry F; Bell, Matthew R; Bailey, Laura S; Polfer, Nicolas C

    2017-07-27

    We demonstrate operation of the first cryogenic 2D linear ion trap (LIT) with mass-selective capabilities. This trap presents a number of advantages for infrared ion "action" spectroscopy studies, particularly those employing the "tagging/messenger" spectroscopy approach. The high trapping efficiencies, trapping capacities, and low detection limits make 2D LITs a highly suitable choice for low-concentration analytes from scarce biological samples. In our trap, ions can be cooled down to cryogenic temperatures to achieve higher-resolution infrared spectra, and individual ions can be mass selected prior to irradiation for a background-free photodissociation scheme. Conveniently, multiple tagged analyte ions can be mass isolated and efficiently irradiated in the same experiment, allowing their infrared spectra to be recorded in parallel. This multiplexed approach is critical in terms of increasing the duty cycle of infrared ion spectroscopy, which is currently a key weakness of the technique. The compact design of this instrument, coupled with powerful mass selection capabilities, set the stage for making cryogenic infrared ion spectroscopy viable as a bioanalytical tool in small molecule identification. This article is protected by copyright. All rights reserved.

  18. Degradation study of enniatins by liquid chromatography-triple quadrupole linear ion trap mass spectrometry.

    Science.gov (United States)

    Serrano, A B; Meca, G; Font, G; Ferrer, E

    2013-12-15

    Enniatins A, A1, B and B1 (ENs) are mycotoxins produced by Fusarium spp. and are normal contaminants of cereals and derivate products. In this study, the stability of ENs was evaluated during food processing by simulation of pasta cooking. Thermal treatments at different incubation times (5, 10 and 15 min) and different pH (4, 7 and 10) were applied in an aqueous system and pasta resembling system (PRS). The concentrations of the targeted mycotoxins were determined using liquid chromatography coupled to tandem mass spectrometry. High percentages of ENs reduction (81-100%) were evidenced in the PRS after the treatments at 5, 10 and 15 min of incubation. In contrast to the PRS, an important reduction of the ENs was obtained in the aqueous system after 15 min of incubation (82-100%). In general, no significant differences were observed between acid, neutral and basic solutions. Finally, several ENs degradation products were identified using the technique of liquid chromatography-triple quadrupole linear ion trap mass spectrometry.

  19. Development of a Linear Ion Trap Mass Spectrometer (LITMS) Investigation for Future Planetary Surface Missions

    Science.gov (United States)

    Brinckerhoff, W.; Danell, R.; Van Ameron, F.; Pinnick, V.; Li, X.; Arevalo, R.; Glavin, D.; Getty, S.; Mahaffy, P.; Chu, P.; Zacny, K.; Rogacki, S.; Grubisic, A.; Cornish, T.

    2014-01-01

    Future surface missions to Mars and other planetary bodies will benefit from continued advances in miniature sensor and sample handling technologies that enable high-performance chemical analyses of natural samples. Fine-scale (approx.1 mm and below) analyses of rock surfaces and interiors, such as exposed on a drill core, will permit (1) the detection of habitability markers including complex organics in association with their original depositional environment, and (2) the characterization of successive layers and gradients that can reveal the time-evolution of those environments. In particular, if broad-based and highly-sensitive mass spectrometry techniques could be brought to such scales, the resulting planetary science capability would be truly powerful. The Linear Ion Trap Mass Spectrometer (LITMS) investigation is designed to conduct fine-scale organic and inorganic analyses of short (approx.5-10 cm) rock cores such as could be acquired by a planetary lander or rover arm-based drill. LITMS combines both pyrolysis/gas chromatograph mass spectrometry (GCMS) of sub-sampled core fines, and laser desorption mass spectrometry (LDMS) of the intact core surface, using a common mass analyzer, enhanced from the design used in the Mars Organic Molecule Analyzer (MOMA) instrument on the 2018 ExoMars rover. LITMS additionally features developments based on the Sample Analysis at Mars (SAM) investigation on MSL and recent NASA-funded prototype efforts in laser mass spectrometry, pyrolysis, and precision subsampling. LITMS brings these combined capabilities to achieve its four measurement objectives: (1) Organics: Broad Survey Detect organic molecules over a wide range of molecular weight, volatility, electronegativity, concentration, and host mineralogy. (2) Organic: Molecular Structure Characterize internal molecular structure to identify individual compounds, and reveal functionalization and processing. (3) Inorganic Host Environment Assess the local chemical

  20. Linear ion-trap mass spectrometric characterization of human pituitary nitrotyrosine-containing proteins

    Science.gov (United States)

    Zhan, Xianquan; Desiderio, Dominic M.

    2007-01-01

    The nitric oxide-mediated Tyr-nitration of endogenous proteins is associated with several pathological and physiological processes. In order to investigate the presence - and potential roles - of Tyr-nitration in the human pituitary, a large-format two-dimensional gel separation plus a Western blot against a specific anti-3-nitrotyrosine antibody were used to separate and detect nitroproteins from a human pituitary proteome. The nitroproteins were subjected to in-gel trypsin digestion, and high-sensitivity vacuum matrix-assisted laser desorption/ionization (vMALDI) linear ion-trap tandem mass spectrometry was used to analyze the tryptic peptides. Those MS/MS data were used to determine the amino acid sequence and the specific nitration site of each tryptic nitropeptide, and were matched to corresponding proteins with Bioworks TuboSEQUEST software. Compared to our previous study, 16 new nitrotyrosine-immunoreactive positive Western blot spots were found within the area pI 3.0-10 and Mr 10-100 kDa. Four new nitroproteins were discovered: the stanniocalcin 1 precursor--involved in calcium and phosphate metabolism; mitochondrial co-chaperone protein HscB, which might act as a co-chaperone in iron-sulfur cluster assembly in mitochrondria; progestin and adipoQ receptor family member III--a seven-transmembrane receptor; proteasome subunit alpha type 2--involved in an ATP/ubiquitin-dependent non-lysosomal proteolytic pathway. Those data demonstrate that nitric oxide-mediated Tyr-nitration might participate in various biochemical, metabolic, and pathological processes in the human pituitary.

  1. Determination of vanillin, ethyl vanillin, and coumarin in infant formula by liquid chromatography-quadrupole linear ion trap mass spectrometry.

    Science.gov (United States)

    Shen, Yan; Han, Chao; Liu, Bin; Lin, Zhengfeng; Zhou, Xiujin; Wang, Chengjun; Zhu, Zhenou

    2014-02-01

    A simple, precise, accurate, and validated liquid chromatography-quadrupole linear ion trap mass spectrometry method was developed for the determination of vanillin, ethyl vanillin, and coumarin in infant formula samples. Following ultrasonic extraction with methanol/water (1:1, vol/vol), and clean-up on an HLB solid-phase extraction cartridge (Waters Corp., Milford, MA), samples were separated on a Waters XSelect HSS T3 column (150 × 2.1-mm i.d., 5-μm film thickness; Waters Corp.), with 0.1% formic acid solution-acetonitrile as mobile phase at a flow rate of 0.25 mL/min. Quantification of the target was performed by the internal standard approach, using isotopically labeled compounds for each chemical group, to correct matrix effects. Data acquisition was carried out in multiple reaction monitoring transitions mode, monitoring 2 multiple reaction monitoring transitions to ensure an accurate identification of target compounds in the samples. Additional identification and confirmation of target compounds were performed using the enhanced product ion modus of the linear ion trap. The novel liquid chromatography-quadrupole linear ion trap mass spectrometry platform offers the best sensitivity and specificity for characterization and quantitative determination of vanillin, ethyl vanillin, and coumarin in infant formula and fulfills the quality criteria for routine laboratory application.

  2. Quantitative determination of multi markers in five varieties of Withania somnifera using ultra-high performance liquid chromatography with hybrid triple quadrupole linear ion trap mass spectrometer combined with multivariate analysis: Application to pharmaceutical dosage forms.

    Science.gov (United States)

    Chandra, Preeti; Kannujia, Rekha; Saxena, Ankita; Srivastava, Mukesh; Bahadur, Lal; Pal, Mahesh; Singh, Bhim Pratap; Kumar Ojha, Sanjeev; Kumar, Brijesh

    2016-09-10

    An ultra-high performance liquid chromatography electrospray ionization tandem mass spectrometry method has been developed and validated for simultaneous quantification of six major bioactive compounds in five varieties of Withania somnifera in various plant parts (leaf, stem and root). The analysis was accomplished on Waters ACQUITY UPLC BEH C18 column with linear gradient elution of water/formic acid (0.1%) and acetonitrile at a flow rate of 0.3mLmin(-1). The proposed method was validated with acceptable linearity (r(2), 0.9989-0.9998), precision (RSD, 0.16-2.01%), stability (RSD, 1.04-1.62%) and recovery (RSD ≤2.45%), under optimum conditions. The method was also successfully applied for the simultaneous determination of six marker compounds in twenty-six marketed formulations. Hierarchical cluster analysis and principal component analysis were applied to discriminate these twenty-six batches based on characteristics of the bioactive compounds. The results indicated that this method is advance, rapid, sensitive and suitable to reveal the quality of Withania somnifera and also capable of performing quality evaluation of polyherbal formulations having similar markers/raw herbs. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Screening and Confirmation of Phthalates in Food Contact Materials by Hybrid Linear Ion Trap/Orbitrap Mass Spectrometry%食品接触材料中邻苯二甲酸酯的LTQ-Orbitrap组合式高分辨质谱快速筛查和确证

    Institute of Scientific and Technical Information of China (English)

    王晓兵; 丁利; 朱绍华; 戴华; 许宙; 焦艳娜; 王利岳

    2011-01-01

    A fast screening and conformation method of phthalates in food contact materials based on liquid chromatography mass spectrometry using a linear ion trap-orbitrap hybrid instrument at high mass resolution(HPLC-LTQ-Oribitrap/MS) was developed.Accelerated s%建立了食品接触材料中邻苯二甲酸酯快速筛查确证的高效液相色谱-高分辨质谱法(HPLC-LTQ-Orbi-trap/MS)。实验中采用加速溶剂萃取(ASE)法为样品前处理手段,优化了萃取溶剂、萃取温度、静态萃取时间等实验参数,提高了食品接触材料中邻苯二甲酸酯的提取效率。采用高分辨质谱有效地去除了基体干扰,通过静电场轨道阱全扫描得到的精确相对分子质量进行了化合物的定量,用离子阱的二级质谱图对未知化合物进行了进一步确证。结果表明:邻苯二甲酸酯的检测限为1 ng/mL;该方法的加标回收率为89.8%~101.3%,

  4. Advanced Resolution Organic Molecule Analyzer (AROMA): Simulations, Development and Initial Testing of a Linear Ion Trap-Orbitrap Instrument for Space

    Science.gov (United States)

    Arevalo, R.; Danell, R. M.; Gundersen, C.; Hovmand, L.; Southard, A.; Tan, F.; Grubisic, A.; Brinckerhoff, W. B.; Getty, S. A.; Mahaffy, P.; Cottin, H.; Briois, C.; Colin, F.; Szopa, C.; Vuitton, V.; Makarov, A.; Reinhardt-Szyba, M.

    2016-10-01

    AROMA combines a linear ion trap and Orbitrap mass analyzer to enable: quantitative measurements of organic and inorganic compounds; selective isolation of targeted mass ranges; tandem mass spectrometry; and, ultrahigh mass resolution and accuracy.

  5. A Generic Multiple Reaction Monitoring Based Approach for Plant Flavonoids Profiling Using a Triple Quadrupole Linear Ion Trap Mass Spectrometry

    Science.gov (United States)

    Yan, Zhixiang; Lin, Ge; Ye, Yang; Wang, Yitao; Yan, Ru

    2014-06-01

    Flavonoids are one of the largest classes of plant secondary metabolites serving a variety of functions in plants and associating with a number of health benefits for humans. Typically, they are co-identified with many other secondary metabolites using untargeted metabolomics. The limited data quality of untargeted workflow calls for a shift from the breadth-first to the depth-first screening strategy when a specific biosynthetic pathway is focused on. Here we introduce a generic multiple reaction monitoring (MRM)-based approach for flavonoids profiling in plants using a hybrid triple quadrupole linear ion trap (QTrap) mass spectrometer. The approach includes four steps: (1) preliminary profiling of major aglycones by multiple ion monitoring triggered enhanced product ion scan (MIM-EPI); (2) glycones profiling by precursor ion triggered EPI scan (PI-EPI) of major aglycones; (3) comprehensive aglycones profiling by combining MIM-EPI and neutral loss triggered EPI scan (NL-EPI) of major glycone; (4) in-depth flavonoids profiling by MRM-EPI with elaborated MRM transitions. Particularly, incorporation of the NH3 loss and sugar elimination proved to be very informative and confirmative for flavonoids screening. This approach was applied for profiling flavonoids in Astragali radix ( Huangqi), a famous herb widely used for medicinal and nutritional purposes in China. In total, 421 flavonoids were tentatively characterized, among which less than 40 have been previously reported in this medicinal plant. This MRM-based approach provides versatility and sensitivity that required for flavonoids profiling in plants and serves as a useful tool for plant metabolomics.

  6. Development of a linear ion trap/orthogonal-time-of-flight mass spectrometer for time-dependent observation of product ions by ultraviolet photodissociation of peptide ions.

    Science.gov (United States)

    Kim, Tae-Young; Schwartz, Jae C; Reilly, James P

    2009-11-01

    A hybrid linear ion trap/orthogonal time-of-flight (TOF) mass spectrometer has been developed to observe time-dependent vacuum ultraviolet photodissociation product ions. In this apparatus, a reflectron TOF mass analyzer is orthogonally interfaced to an LTQ using rf-only octopole and dc quadrupole ion guides. Precursor ions are generated by electrospray ionization and isolated in the ion trap. Subsequently they are directed to the TOF source where photodissociation occurs and product ions are extracted for mass analysis. To detect photodissociation product ions having axially divergent trajectories, a large rectangular detector is utilized. With variation of the time between photodissociation and orthogonal extraction in the TOF source, product ions formed over a range of times after photoexcitation can be sampled. Time-dependent observation of product ions following 157 nm photodissociation of a singly charged tryptic peptide ion (NWDAGFGR) showed that prompt photofragment ions (x- and v-type ions) dominate the tandem mass spectrum up to 1 micros after the laser shot, but the intensities of low energy thermal fragment ions (y-type ions) become comparable several microseconds later. Different proton mobilization time scales were observed for arginine- and lysine-terminated tryptic peptides.

  7. Prospects for Ultra-Stable Timekeeping with Sealed Vacuum Operation in Multi-Pole Linear Ion Trap Standards

    Science.gov (United States)

    Burt, Eric A.; Tjoelker, R. L.

    2007-01-01

    A recent long-term comparison between the compensated multi-pole Linear Ion Trap Standard (LITS) and the laser-cooled primary standards via GPS carrier phase time transfer showed a deviation of less than 2.7x10(exp -17)/day. A subsequent evaluation of potential drift contributors in the LITS showed that the leading candidates are fluctuations in background gases and the neon buffer gas. The current vacuum system employs a "flow-through" turbomolecular pump and a diaphragm fore pump. Here we consider the viability of a "sealed" vacuum system pumped by a non-evaporable getter for long-term ultra-stable clock operation. Initial tests suggests that both further stability improvement and longer mean-time-between-maintenance can be achieved using this approach

  8. Analysis of Seven Drugs in Human Hair by Hybrid Linear Ion Trap/Orbitrap Mass Spectrometry%LTQ-Orbitrap组合式高分辨质谱法快速筛查毛发中7种毒品及代谢物

    Institute of Scientific and Technical Information of China (English)

    叶海英; 郑水庆; 梁晨; 汪蓉; 张玉荣; 张凌怡; 张维冰; 张润生

    2012-01-01

    A new method was developed for the determination of seven illicit drugs and metabolites in human hair by ultra high performance liquid chromatograph tandem a linear ion trap-orbitrap hybrid instrument at high mass resolution (UHPLC-LTQ-Orbitrap/MS). After being washed and grinded, the hair samples were soaked in pH 9. 2 borate buffer with ultrasonic for 90 min. Then the samples were extracted by solid phase extraction (SPE). High resolution mass spectrometry was applied to reduce matrix interference. Full scanning of electrostatic field orbitrap was applied for quantification of drugs. The limits of detection (LOD) of seven illicit drugs and metabolites in human hair were 0. 001 -0. 02 μg/g. The method showed a fairly good linearity over the range of 0. 05 - 50 μg/g (r>0. 9975). The spiked recoveries were between 76. 1% -109. 6% , and the deviation of intra- and inter- day precision was less than 14. 9%. The method is simple, high sensitive, and suitable for the determination of illicit drugs in human hair.%采用超高压液相色谱-二维线性离子阱结合静电场轨道阱组合式高分辨质谱联用技术(Accela U-HPLC/LTQ Orbitrap XL),建立了人毛发中吗啡、O6-单乙酰吗啡、可待因、乙酰可待因、氯胺酮、去甲氯胺酮和美沙酮毒品及代谢物快速筛查方法.取毛发样品经表层清洗后冷冻研磨粉碎,置于硼酸盐缓冲液(pH 9.2)中超声90 min,离心取上清液,用Oasis HLB柱固相萃取制备.通过静电场轨道阱全扫描得到毒品及其代谢物的精确相对分子质量,同时进行7种毒品及其代谢物的快速筛查.高分辨率质谱可有效去除毛发基质干扰,毒品及其代谢物筛查检出限在0.001~0.02 ng/mg,在0.05~50 ng/mg范围内存在良好线性关系(r>0.9975);本方法平均加标回收率为76.1%~109.6%;日内及日间精密度RSD≤14.9%.本方法灵敏度高,样品制备简便,适用于常见毒品的快速筛查.

  9. Ejection of Coulomb Crystals from a Linear Paul Ion Trap for Ion-Molecule Reaction Studies.

    Science.gov (United States)

    Meyer, K A E; Pollum, L L; Petralia, L S; Tauschinsky, A; Rennick, C J; Softley, T P; Heazlewood, B R

    2015-12-17

    Coulomb crystals are being increasingly employed as a highly localized source of cold ions for the study of ion-molecule chemical reactions. To extend the scope of reactions that can be studied in Coulomb crystals-from simple reactions involving laser-cooled atomic ions, to more complex systems where molecular reactants give rise to multiple product channels-sensitive product detection methodologies are required. The use of a digital ion trap (DIT) and a new damped cosine trap (DCT) are described, which facilitate the ejection of Coulomb-crystallized ions onto an external detector for the recording of time-of-flight (TOF) mass spectra. This enables the examination of reaction dynamics and kinetics between Coulomb-crystallized ions and neutral molecules: ionic products are typically cotrapped, thus ejecting the crystal onto an external detector reveals the masses, identities, and quantities of all ionic species at a selected point in the reaction. Two reaction systems are examined: the reaction of Ca(+) with deuterated isotopologues of water, and the charge exchange between cotrapped Xe(+) with deuterated isotopologues of ammonia. These reactions are examples of two distinct types of experiment, the first involving direct reaction of the laser-cooled ions, and the second involving reaction of sympathetically-cooled heavy ions to form a mixture of light product ions. Extensive simulations are conducted to interpret experimental results and calculate optimal operating parameters, facilitating a comparison between the DIT and DCT approaches. The simulations also demonstrate a correlation between crystal shape and image shape on the detector, suggesting a possible means for determining crystal geometry for nonfluorescing ions.

  10. Appropriate choice of collision-induced dissociation energy for qualitative analysis of notoginsenosides based on liquid chromatography hybrid ion trap time-of-flight mass spectrometry.

    Science.gov (United States)

    Wang, Guang-Ji; Fu, Han-Xu; Xiao, Jing-Cheng; Ye, Wei; Rao, Tai; Shao, Yu-Hao; Kang, Dian; Xie, Lin; Liang, Yan

    2016-04-01

    Liquid chromatography hybrid ion trap/time-of-flight mass spectrometry possessesd both the MS(n) ability of ion trap and the excellent resolution of a time-of-flight, and has been widely used to identify drug metabolites and determine trace multi-components for in natural products. Collision energy, one of the most important factors in acquiring MS(n) information, could be set freely in the range of 10%-400%. Herein, notoginsenosides were chosen as model compounds to build a novel methodology for the collision energy optimization. Firstly, the fragmental patterns of the representatives for the authentic standards of protopanaxadiol-type and protopanaxatriol-type notoginsenosides authentic standards were obtained based on accurate MS(2) and MS(3) measurements via liquid chromatography hybrid ion trap/time-of-flight mass spectrometry. Then the extracted ion chromatograms of characteristic product ions of notoginsenosides in Panax Notoginseng Extract, which were produced under a series of collision energies and, were compared to screen out the optimum collision energies values for MS(2) and MS(3). The results demonstrated that the qualitative capability of liquid chromatography hybrid ion trap/time-of-flight mass spectrometry was greatly influenced by collision energies, and 50% of MS(2) collision energy was found to produce the highest collision-induced dissociation efficiency for notoginsenosides. BesidesAddtionally, the highest collision-induced dissociation efficiency appeared when the collision energy was set at 75% in the MS(3) stage.

  11. Design of blade-shaped-electrode linear ion traps with reduced anharmonic contributions

    Energy Technology Data Exchange (ETDEWEB)

    Deng, K.; Che, H.; Ge, Y. P.; Xu, Z. T.; Yuan, W. H.; Zhang, J.; Lu, Z. H., E-mail: zehuanglu@mail.hust.edu.cn [MOE Key Laboratory of Fundamental Physical Quantities Measurement, School of Physics, Huazhong University of Science and Technology, 1037 Luoyu Road, Wuhan 430074 (China); Lan, Y. [MOE Key Laboratory of Fundamental Physical Quantities Measurement, School of Physics, Huazhong University of Science and Technology, 1037 Luoyu Road, Wuhan 430074 (China); Department of Physics and Astronomy, University of British Columbia, Vancouver, BC V6T 1Z1 (Canada)

    2015-09-21

    RF quadrupole linear Paul traps are versatile tools in quantum physics experiments. Linear Paul traps with blade-shaped electrodes have the advantages of larger solid angles for fluorescence collection. But with these kinds of traps, the existence of higher-order anharmonic terms of the trap potentials can cause large heating rate for the trapped ions. In this paper, we theoretically investigate the dependence of higher-order terms of trap potentials on the geometry of blade-shaped traps, and offer an optimized design. A modified blade electrodes trap is proposed to further reduce higher-order anharmonic terms while still retaining large fluorescence collection angle.

  12. A linear radiofrequency quadrupole ion trap for the cooling and bunching of radioactive ion beams

    CERN Document Server

    Kellerbauer, A G; Dilling, J; Henry, S; Herfurth, F; Kluge, H J; Lamour, E; Moore, R B; Scheidenberger, C; Schwarz, S; Sikler, G; Szerypo, J

    2002-01-01

    A linear radiofrequency quadrupole ion guide and beam buncher has been installed at the ISOLTRAP mass spectrometry experiment at the ISOLDE facility at CERN. The apparatus is being used as a beam cooling, accumulation, and bunching system. It operates with a buffer gas that cools the injected ions and converts the quasicontinuous 60- keV beam from the ISOLDE facility to 2.5-keV beam pulses with improved normalized transverse emittance. Recent measurements suggest a capture efficiency of the ion guide of up to 40% and a cooling and bunching efficiency of at least 12% which is expected to still be increased. The improved ISOLTRAP setup has so far been used very successfully in three on-line experiments. (12 refs).

  13. Trace analysis of pesticides in paddy field water by direct injection using liquid chromatography-quadrupole-linear ion trap-mass spectrometry.

    Science.gov (United States)

    Pareja, Lucía; Martínez-Bueno, M J; Cesio, Verónica; Heinzen, Horacio; Fernández-Alba, A R

    2011-07-29

    A multiresidue method was developed for the quantification and confirmation of 70 pesticides in paddy field water. After its filtration, water was injected directly in a liquid chromatograph coupled to a hybrid triple quadrupole-linear ion trap-mass spectrometer (QqLIT). The list of target analytes included organophosphates, phenylureas, sulfonylureas, carbamates, conazoles, imidazolinones and others compounds widely used in different countries where rice is cropped. Detection and quantification limits achieved were in the range from 0.4 to 80 ng L(-1) and from 2 to 150 ng L(-1), respectively. Correlation coefficients for the calibration curves in the range 0.1-50 μg L(-1) were higher than 0.99 except for diazinon (0.1-25 μg L(-1)). Only 9 pesticides presented more than 20% of signal suppression/enhancement, no matrix effect was observed in the studied conditions for the rest of the target pesticides. The method developed was used to investigate the occurrence of pesticides in 59 water samples collected in paddy fields located in Spain and Uruguay. The study shows the presence of bensulfuron methyl, tricyclazole, carbendazim, imidacloprid, tebuconazole and quinclorac in a concentration range from 0.08 to 7.20 μg L(-1). Copyright © 2011 Elsevier B.V. All rights reserved.

  14. MRM screening/biomarker discovery with linear ion trap MS: a library of human cancer-specific peptides

    Directory of Open Access Journals (Sweden)

    Lazar Iulia M

    2009-03-01

    Full Text Available Abstract Background The discovery of novel protein biomarkers is essential in the clinical setting to enable early disease diagnosis and increase survivability rates. To facilitate differential expression analysis and biomarker discovery, a variety of tandem mass spectrometry (MS/MS-based protein profiling techniques have been developed. For achieving sensitive detection and accurate quantitation, targeted MS screening approaches, such as multiple reaction monitoring (MRM, have been implemented. Methods MCF-7 breast cancer protein cellular extracts were analyzed by 2D-strong cation exchange (SCX/reversed phase liquid chromatography (RPLC separations interfaced to linear ion trap MS detection. MS data were interpreted with the Sequest-based Bioworks software (Thermo Electron. In-house developed Perl-scripts were used to calculate the spectral counts and the representative fragment ions for each peptide. Results In this work, we report on the generation of a library of 9,677 peptides (p a, b, y ions in the spectrum, the retention time, and the top 10 most intense product ions that correspond to a given peptide. Only proteins identified by at least two spectral counts are listed. The experimental distribution of protein frequencies, as a function of molecular weight, closely matched the theoretical distribution of proteins in the human proteome, as provided in the SwissProt database. The amino acid sequence coverage of the identified proteins ranged from 0.04% to 98.3%. The highest-abundance proteins in the cellular extract had a molecular weight (MW Conclusion Preliminary experiments have demonstrated that putative biomarkers, that are not detectable by conventional data dependent MS acquisition methods in complex un-fractionated samples, can be reliable identified with the information provided in this library. Based on the spectral count, the quality of a tandem mass spectrum and the m/z values for a parent peptide and its most abundant daughter

  15. Microfabricated ion trap array

    Science.gov (United States)

    Blain, Matthew G.; Fleming, James G.

    2006-12-26

    A microfabricated ion trap array, comprising a plurality of ion traps having an inner radius of order one micron, can be fabricated using surface micromachining techniques and materials known to the integrated circuits manufacturing and microelectromechanical systems industries. Micromachining methods enable batch fabrication, reduced manufacturing costs, dimensional and positional precision, and monolithic integration of massive arrays of ion traps with microscale ion generation and detection devices. Massive arraying enables the microscale ion traps to retain the resolution, sensitivity, and mass range advantages necessary for high chemical selectivity. The reduced electrode voltage enables integration of the microfabricated ion trap array with on-chip circuit-based rf operation and detection electronics (i.e., cell phone electronics). Therefore, the full performance advantages of the microfabricated ion trap array can be realized in truly field portable, handheld microanalysis systems.

  16. Simultaneous qualitative and quantitative analysis of 21 mycotoxins in Radix Paeoniae Alba by ultra-high performance liquid chromatography quadrupole linear ion trap mass spectrometry and QuEChERS for sample preparation.

    Science.gov (United States)

    Xing, Yanyan; Meng, Wenting; Sun, Wanyang; Li, Dongxiang; Yu, Zhiguo; Tong, Ling; Zhao, Yunli

    2016-09-15

    A high-throughput method for simultaneous qualitative and quantitative analysis of 21 mycotoxins in Radix Paeoniae Alba (RPA) was developed by coupling the modified QuEChERS method with ultra-high performance liquid chromatography quadrupole linear ion trap mass spectrometry (UHPLC-QqLIT-MS). The 21 mycotoxins were extracted and cleaned up using QuEChERS-based procedure, then further separated on a C18 column and detected by a hybrid triple quadrupole linear ion trap mass spectrometer equipped with electrospray ionization source in the multiple reaction monitoring-information dependent acquisition-enhanced product ion (MRM-IDA-EPI) mode. Under this technique, 13 mycotoxins were detected using acetonitrile and water containing 0.1% formic acid as the mobile phase in positive mode while the other 8 mycotoxins were detected using acetonitrile and water containing 0.1% ammonia as the mobile phase in negative mode. The calibration curves of all analytes showed good linearity (r(2)>0.995) within test ranges. The limits of detection and quantification ranged from 0.031 to 5.4μg/kg and 0.20 to 22μg/kg, respectively. Additionally, recoveries were all above 75.3% with relative standard deviations within 15%. The method proposed herein with significant advantages including simple pretreatment, rapid determination as well as high sensitivity, accuracy and throughput would be a preferred candidate for the determination and quantification of multi-class mycotoxin contaminants in real samples.

  17. Ion trap simulation tools.

    Energy Technology Data Exchange (ETDEWEB)

    Hamlet, Benjamin Roger

    2009-02-01

    Ion traps present a potential architecture for future quantum computers. These computers are of interest due to their increased power over classical computers stemming from the superposition of states and the resulting capability to simultaneously perform many computations. This paper describes a software application used to prepare and visualize simulations of trapping and maneuvering ions in ion traps.

  18. [Rapid screening and confirming carcinogenic banned azo colorants in textiles by high performance liquid chromatography-linear ion trap/orbitrap high-resolution mass spectrometry].

    Science.gov (United States)

    Yun, Huan; Liu, Xin; Wang, Jing; Yan, Hua; Cui, Fengyun; Zhang, Zhaohui

    2013-09-01

    A method of high performance liquid chromatography-linear ion trap/orbitrap highresolution mass spectrometry (HPLC-LTP/Orbitrap MS) was ued to screen and confirm-banned azo colorants in textiles rapidly. The analytes were reduced to carcinogenic aromatic amines with sodium dithionite in citrate buffer solution. The reduced solution was extracted bydiatomite, and loadd onto an Acquity UPLC BEH C18 column (50 mm x 2.1 MM. 1.7 microm) with a gradient elution of methanol and 0.1% (v/v) methane acid aqueous solution, and finally detected by linear ion trap/orbitrap high-resolution mass spectrometry in positive ESI mode. In mass spectrometry method, the MS spectrum of high-resolution and the collision induced dissociation (CID) spectrum of data-dependent scan mode were used for screening analysis and conformation, respectively. The calibration curves showed a good linearity in the range of 0.05 -2.00 mg/b, and the correlation coefficients (r) were higher than 0.99. By detecting spiked samples, the limits of quantification were 0.08 mg/kg for all the residues and the recoveries were in the range of 65.5% - 111.5% with the relative standard deviations (RSDs) between 0.87% and 2.49%. The results indicate that the method is simple, rapid, sensitive and suitable for the qualitative and quantitative analysis of carcinogenic aromatic amines in textiles.

  19. Rapid quantification of four major bioactive alkaloids in Corydalis decumbens (Thunb.) Pers. by pressurised liquid extraction combined with liquid chromatography-triple quadrupole linear ion trap mass spectrometry.

    Science.gov (United States)

    Shen, Yan; Han, Chao; Jiang, Yongxiang; Zhou, Xiujin; Zhu, Zhenou; Lei, Xinxiang

    2011-05-30

    A new method based on pressurised liquid extraction (PLE) followed by liquid chromatography-triple quadrupole linear ion trap mass spectrometry (LC-QTrap-MS) analysis has been developed for the identification and quantification of four major alkaloids in extracts of Corydalis decumbens (Thunb.) Pers. PLE extractions were performed using 90% ethanol; temperature was set at 100°C and pressure at 1500 psi. HPLC analysis was performed on a Waters XBridge™ C(18) column (150 mm × 2.1mm i.d., 3.5 μm) eluted by a mobile phase of acetonitrile and 0.2% acetic acid. Data acquisition was carried out in multiple reaction monitoring transitions (MRMs) mode, monitoring two MRM transitions to ensure an accurate identification of target compounds in the samples. Additional identification and confirmation of target compounds were performed using the enhanced product ion modus (EPI) of the linear ion trap. The novel LC-QTrap-MS platform offers the best sensitivity and specificity for characterization and quantitative determination of the four alkaloids in C. decumbens (Thunb.) Pers. and fulfils the quality criteria for routine laboratory application.

  20. Collision-induced dissociation pathways of yeast sphingolipids and their molecular profiling in total lipid extracts: a study by quadrupole TOF and linear ion trap-orbitrap mass spectrometry

    DEFF Research Database (Denmark)

    Ejsing, Christer S.; Moehring, Thomas; Bahr, Ute

    2006-01-01

    and the long chain base moieties in individual molecular species. By selecting m/z of class-specific fragment ions for multiple precursor ion scanning, we profiled yeast sphingolipids in total lipid extracts on a QqTOF mass spectrometer. Thus, a combination of QqTOF and LTQ Orbitrap mass spectrometry lends......TOF) instrument produced fragments of inositol-containing head groups, which were specific for each lipid class. MS(n) analysis performed on a hybrid linear ion trap-orbitrap (LTQ Orbitrap) mass spectrometer with better than 3 ppm mass accuracy identified fragment ions specific for the amide-linked fatty acid...... itself to rapid, comprehensive and structure-specific profiling of the molecular composition of sphingolipids and glycerophospholipids in important model organisms, such as fungi and plants....

  1. Metabolite Profile of Salidroside in Rats by Ultraperformance Liquid Chromatography Coupled with Quadrupole Time-of-Flight Mass Spectrometry and High-Performance Liquid Chromatography Coupled with Quadrupole-Linear Ion Trap Mass Spectrometry.

    Science.gov (United States)

    Hu, Zhiwei; Wang, Ziming; Liu, Yong; Wu, Yan; Han, Xuejiao; Zheng, Jian; Yan, Xiufeng; Wang, Yang

    2015-10-21

    In the present work, the salidroside metabolite profile in rat urine was investigated, and subsequently the metabolic pathways of salidroside were proposed. After administrations of salidroside at an oral dose of 100 or 500 mg/kg, rat urine samples were collected and pretreated with methanol to precipitate the proteins. The pretreated samples were analyzed by an Acquity ultraperformance liquid chromatography (UPLC) coupled with an HSS T3 column and detected by quadrupole time-of-flight mass spectrometry (Q-TOF-MS) or high-performance liquid chromatography coupled with hybrid triple-quadrupole linear ion trap mass spectrometry (HPLC/Q-trap-MS). A total of eight metabolites were detected and identified on the basis of the characteristics of their protonated ions in the urine samples. The results elucidated that salidroside was metabolized via glucuronidation, sulfation, deglycosylation, hydroxylation, methylation, and dehydroxylation pathways in vivo.

  2. Microfabricated cylindrical ion trap

    Science.gov (United States)

    Blain, Matthew G.

    2005-03-22

    A microscale cylindrical ion trap, having an inner radius of order one micron, can be fabricated using surface micromachining techniques and materials known to the integrated circuits manufacturing and microelectromechanical systems industries. Micromachining methods enable batch fabrication, reduced manufacturing costs, dimensional and positional precision, and monolithic integration of massive arrays of ion traps with microscale ion generation and detection devices. Massive arraying enables the microscale cylindrical ion trap to retain the resolution, sensitivity, and mass range advantages necessary for high chemical selectivity. The microscale CIT has a reduced ion mean free path, allowing operation at higher pressures with less expensive and less bulky vacuum pumping system, and with lower battery power than conventional- and miniature-sized ion traps. The reduced electrode voltage enables integration of the microscale cylindrical ion trap with on-chip integrated circuit-based rf operation and detection electronics (i.e., cell phone electronics). Therefore, the full performance advantages of microscale cylindrical ion traps can be realized in truly field portable, handheld microanalysis systems.

  3. Planar Ion Trap Geometry for Microfabrication

    CERN Document Server

    Madsen, M J; Stick, D; Rabchuk, J A; Monroe, C

    2004-01-01

    We describe a novel high aspect ratio radiofrequency linear ion trap geometry that is amenable to modern microfabrication techniques. The ion trap electrode structure consists of a pair of stacked conducting cantilevers resulting in confining fields that take the form of fringe fields from parallel plate capacitors. The confining potentials are modeled both analytically and numerically. This ion trap geometry may form the basis for large scale quantum computers or parallel quadrupole mass spectrometers. PACS: 39.25.+k, 03.67.Lx, 07.75.+h, 07.10+Cm

  4. Extraction and Analysis of Disperse Dyes from Colored Polyester Single Fibers Using Liquid Chromatography/Linear Ion Trap Tandem Mass Spectrometry.

    Science.gov (United States)

    Kato, Takao; Suzuki, Yasuhiro; Handa, Makoto

    2016-01-01

    Nine disperse dyes extracted from colored polyester threads and single fibers of manufactory-supplied textiles by using centrifugal filtration were analyzed using liquid chromatography/linear ion trap tandem mass spectrometry (LC/LIT-MS(n)). Based on diode array detector data, dimethylformamide (DMF) was found to be a more effective extraction solvent than acetonitrile/water (4:3, v/v) or methanol/water (1:1, v/v) mixtures. The precursor, [M+H](+) ions, were detected for the dyes extracted using DMF. The MS(2) and MS(3) spectra also matched those of the standard disperse dyes. Without relying on comparison clothes, disperse dyes extracted from the single fibers (5 mm in length) were successfully identified by LC/LIT-MS(n) and the custom-built database.

  5. Superconducting microfabricated ion traps

    CERN Document Server

    Wang, Shannon X; Labaziewicz, Jaroslaw; Dauler, Eric; Berggren, Karl; Chuang, Isaac L

    2010-01-01

    We fabricate superconducting ion traps with niobium and niobium nitride and trap single 88Sr ions at cryogenic temperatures. The superconducting transition is verified and characterized by measuring the resistance and critical current using a 4-wire measurement on the trap structure, and observing change in the rf reflection. The lowest observed heating rate is 2.1(3) quanta/sec at 800 kHz at 6 K and shows no significant change across the superconducting transition, suggesting that anomalous heating is primarily caused by noise sources on the surface. This demonstration of superconducting ion traps opens up possibilities for integrating trapped ions and molecular ions with superconducting devices.

  6. Qualitative analysis of major constituents from Xue Fu Zhu Yu Decoction using ultra high performance liquid chromatography with hybrid ion trap time-of-flight mass spectrometry.

    Science.gov (United States)

    Fu, Chunyan; Xia, Zian; Liu, Yonghui; Lu, Hongmei; Zhang, Zhimin; Wang, Yang; Fan, Xiaqiong

    2016-09-01

    Xue Fu Zhu Yu Decoction, a famous formula that has been used for treating many blood stasis-caused diseases for many centuries, comprises 11 kinds of traditional Chinese medicines. A convenient, efficient, and rapid analytical method was developed to simultaneously determine the major compounds in this decoction. An ultra-high performance liquid chromatography with hybrid ion trap time-of-flight mass spectrometry method was used to rapidly separate and detect the major constituents of the decoction. Using this technique, we identified or tentatively identified 34 compounds, including 21 flavonoids, 5 terpenoids, 3 organic acids, 2 lactones, 1 alkaloid, 1 amino acid, and 1 cyanogenic glycoside. The MS analysis of these constituents was described in detail. Findings may contribute to future metabolic and pharmacokinetic studies of this medicine.

  7. [Screening and confirmation of 24 hormones in cosmetics by ultra high performance liquid chromatography-linear ion trap/orbitrap high resolution mass spectrometry].

    Science.gov (United States)

    Li, Zhaoyong; Wang, Fengmei; Niu, Zengyuan; Luo, Xin; Zhang, Gang; Chen, Junhui

    2014-05-01

    A method of ultra high performance liquid chromatography-linear ion trap/orbitrap high resolution mass spectrometry (UPLC-LTQ/Orbitrap MS) was established to screen and confirm 24 hormones in cosmetics. Various cosmetic samples were extracted with methanol. The extract was loaded onto a Waters ACQUITY UPLC BEH C18 column (50 mm x 2.1 mm, 1.7 microm) using a gradient elution of acetonitrile/water containing 0.1% (v/v) formic acid for the separation. The accurate mass of quasi-molecular ion was acquired by full scanning of electrostatic field orbitrap. The rapid screening was carried out by the accurate mass of quasi-molecular ion. The confirmation analysis for targeted compounds was performed with the retention time and qualitative fragments obtained by data dependent scan mode. Under the optimal conditions, the 24 hormones were routinely detected with mass accuracy error below 3 x 10(-6) (3 ppm), and good linearities were obtained in their respective linear ranges with correlation coefficients higher than 0.99. The LODs (S/N = 3) of the 24 compounds were hormones in 50 cosmetic samples. The results demonstrate that the method is a useful tool for the rapid screening and identification of the hormones in cosmetics.

  8. Ion Trap Quantum Computing

    Science.gov (United States)

    2011-12-01

    an inspiring speech at the MIT Physics of Computation 1st Conference in 1981, Feynman proposed the development of a computer that would obey the...on ion trap based 36 quantum computing for physics and computer science students would include lecture notes, slides, lesson plans, a syllabus...reading lists, videos, demonstrations, and laboratories. 37 LIST OF REFERENCES [1] R. P. Feynman , “Simulating physics with computers,” Int. J

  9. Determination of 23 β2-agonists and 5 β-blockers in animal muscle by high performance liquid chromatography-linear ion trap mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    A high performance liquid chromatography-linear ion trap mass spectrometry method using isotope dilution technique has been developed for the simultaneous determination of 23 β2-agonists and 5 β-blockers in animal muscle tissues. Pork and chicken muscle samples were acid hydrolyzed and extracted with 5% trichloracetic acid in water, and then cleaned up using MCX solid phase extraction (SPE) cartridge. Methanol and 0.1% formic acid were used as mobile phases for gradient elution. A Waters AtlantisT3 column was used for separation. ESI positive ion scan mode was used with selective reaction monitoring. 9 β2-Agonists labeled by the deuterium isotope were used as internal standards for quantification. The linear ranges of 23 β2-agonists and 5 β-blockers were 5-200 μg/L, the coefficient of correlation was not less than 0.995, and the limit of detection for each compound in the muscle tissue was below 0.2 μg/kg. The recoveries of each compound in the spiked samples at three levels 5, 10, 20 μg/kg were in the range of 47.3%-123.7%, and the relative standard deviations were in the range of 3.2%-25.7%. The developed method is sensitive and specific for the determination of β2-agonists and β-blockers in pork and chicken muscle samples.

  10. MS/MS studies for the selective detection of isomeric biogenic VOCs using a Townsend Discharge Triple Quadrupole Tandem MS and a PTR-Linear Ion Trap MS

    Directory of Open Access Journals (Sweden)

    M. Müller

    2009-08-01

    Full Text Available We performed MS/MS investigations of biogenic volatile organic compounds (BVOC using a triple quadrupole tandem mass spectrometer (QqQ-MS equipped with a Townsend Discharge ion source and a Proton Transfer Reaction Linear Ion Trap (PTR-LIT mass spectrometer. Both instruments use H2O chemical ionization to produce protonated molecular ions. Here we report a study of the application of these instruments to determine methyl vinyl ketone (MVK and methacrolein (MACR and a series of monoterpenes (α-pinene, β-pinene, 3-carene, limonene, myrcene, ocimene and sesquiterpenes (humulene and farnesene. Both instruments achieved sub-ppb detection limits in the single MS mode and in the MS/MS mode for differentiating MVK and MACR. Collision induced dissociation (CID of protonated monoterpenes and sesquiterpenes was studied under the high-energy, single-to-few collision conditions of the QqQ-MS instrument and under the low-energy, multiple collision conditions of the PTR-LIT. Differences and similarities in the breakdown curves obtained are discussed. In addition, we performed MS4 of protonated limonene to illustrate the analytical power of the PTR-LIT. In spite of the progress we have made, the selective on-line mass-spectrometric detection of individual monoterpenes or sesquiterpenes in complex mixtures currently does not yet seem to be possible.

  11. Studies on the metabolism of mitragynine, the main alkaloid of the herbal drug Kratom, in rat and human urine using liquid chromatography-linear ion trap mass spectrometry.

    Science.gov (United States)

    Philipp, Anika A; Wissenbach, Dirk K; Zoerntlein, Siegfried W; Klein, Oliver N; Kanogsunthornrat, Jidapha; Maurer, Hans H

    2009-08-01

    Mitragynine (MG) is an indole alkaloid of the Thai medicinal plant Mitragyna speciosa (Kratom in Thai) and reported to have opioid agonistic properties. Because of its stimulant and euphoric effects, Kratom is used as a herbal drug of abuse. The aim of the presented study is to identify the phase I and II metabolites of MG in rat and human urine after solid-phase extraction (SPE) using liquid chromatography-linear ion trap mass spectrometry providing detailed structure information in the MSn mode particularly with high resolution. The seven identified phase I metabolites indicated that MG was metabolized by hydrolysis of the methylester in position 16, O-demethylation of the 9-methoxy group and of the 17-methoxy group, followed, via the intermediate aldehydes, by oxidation to carboxylic acids or reduction to alcohols and combinations of some steps. In rats, four metabolites were additionally conjugated to glucuronides and one to sulfate, but in humans, three metabolites to glucuronides and three to sulfates.

  12. The use of online heart-cutting high-performance liquid chromatography coupled with linear ion trap mass spectrometry in the identification of impurities in vidarabine monophosphate.

    Science.gov (United States)

    Wang, Hang; Xu, Tongzhou; Yuan, Jiaojian

    2017-02-17

    It is difficult to identify unknown impurities in nucleotide analogues by mass spectrometry because mass-spectrometry-incompatible mobile phases need to be used to separate the major ingredient from impurities. In this study, vidarabine monophosphate was selected, and unknown impurities were identified by online heart-cutting two-dimensional high-performance liquid chromatography and linear ion trap mass spectrometry. The one-dimensional reversed-phase column was filled with a mobile phase containing nonvolatile salt. In two-dimensional high-performance liquid chromatography, we used an Acclaim Q1 column with volatile salt, and the detection wavelength was 260 nm. The mass spectrum was scanned in positive- and negative-ion mode. The online heart-cutting and online demineralization technique ensured that the mobile phase was compatible with mass spectrometry; seven impurities were identified by MS(2) and MS(3) fragments. The mass fragmentation patterns of these impurities were investigated. The two isomers were semiprepared and complemented by nuclear magnetic resonance. The results were further compared with those of normal-phase high-performance liquid chromatography with mass spectrometry. The online heart-cutting two-dimensional high-performance liquid chromatography with mass spectrometry was superior in identifying more impurities. The method solves the problem of incompatibility between the mobile phase and mass spectrometry, so it is suitable for identifying unknown impurities. This method may also be used for investigating impurities in other nucleotide analogues.

  13. Liquid chromatography-electrospray linear ion trap mass spectrometry analysis of targeted neuropeptides in Tac1(-/-) mouse spinal cords reveals significant lower concentration of opioid peptides.

    Science.gov (United States)

    Saidi, Mouna; Beaudry, Francis

    2015-08-01

    Tachykinin and opioid peptides play a central role in pain transmission, modulation and inhibition. The treatment of pain is very important in medicine and many studies using NK1 receptor antagonists failed to show significant analgesic effects in humans. Recent investigations suggest that both pronociceptive tachykinins and the analgesic opioid systems are important for normal pain sensation. The analysis of opioid peptides in Tac1(-/-) spinal cord tissues offers a great opportunity to verify the influence of the tachykinin system on specific opioid peptides. The objectives of this study were to develop an HPLC-MS/MRM assay to quantify targeted peptides in spinal cord tissues. Secondly, we wanted to verify if the Tac1(-/-) mouse endogenous opioid system is hampered and therefore affects significantly the pain modulatory pathways. Targeted neuropeptides were analyzed by high performance liquid chromatography linear ion trap mass spectrometry. Our results reveal that EM-2, Leu-Enk and Dyn A were down-regulated in Tac1(-/-) spinal cord tissues. Interestingly, Dyn A was almost 3 fold down-regulated (p<0.0001). No significant concentration differences were observed in mouse Tac1(-/-) spinal cords for Met-Enk and CGRP. The analysis of Tac1(-/-) mouse spinal cords revealed noteworthy decreases of EM-2, Leu-Enk and Dyn A concentrations which strongly suggest a significant impact on the endogenous pain-relieving mechanisms. These observations may have insightful impact on future analgesic drug developments and therapeutic strategies.

  14. Analysis of anthelmintics in surface water by ultra high performance liquid chromatography coupled to quadrupole linear ion trap tandem mass spectrometry.

    Science.gov (United States)

    Zrnčić, Mirta; Gros, Meritxell; Babić, Sandra; Kaštelan-Macan, Marija; Barcelo, Damia; Petrović, Mira

    2014-03-01

    A method based on ultra high performance liquid chromatography coupled to quadrupole linear ion trap mass spectrometry (UHPLC-QqLIT-MS) has been developed to investigate occurrence of 10 anthelmintic drugs from different structural groups (moxidectin, flubendazole, fenbendazole, levamisol, mebendazole, oxibendazole, albendazole, triclabendazole, febantel and praziquantel) in surface water. Analytes were pre-concentrated by solid phase extraction (SPE) using hydrophilic-lipophilic polymeric based sorbent. Quantification of investigated analytes was done using deuterated compounds as internal standards in order to minimize matrix effect. Analyte recoveries from spiked samples at two concentration levels were above 75% for most of the analytes. The main advantages of developed method are fast separation using UHPLC and therefore short analysis time, combined with good sensitivity which is demonstrated by low ngL(-1) detection limits. The developed method was applied for analysis of anthelmintics in the Llobregat River (NE Spain) and its main tributaries (rivers Anoia and Cardener). Eight out of ten anthelmintics were detected in all analyzed samples with the concentrations in low ngL(-1) level. The method fills the gap on analytical methodologies for determination of anthelmintic drugs in the environment.

  15. Performance of the Linear Ion Trap Mass Spectrometer for the Mars Organic Molecule Analyzer (MOMA) Investigation on the 2018 Exomars Rover

    Science.gov (United States)

    Arevalo, Ricardo, Jr.; Brinckerhoff, William B.; Pinnick, Veronica T.; van Amerom, Friso H. W.; Danell, Ryan M.; Li, Xiang; Getty, Stephanie; Hovmand, Lars; Atanassova, Martina; Mahaffy, Paul R.; Chu, Zhiping; Goesmann, Fred; Steininger, Harald

    2014-01-01

    The 2018 ExoMars rover mission includes the Mars Organic Molecule Analyzer (MOMA) investigation. MOMA will examine the chemical composition of samples acquired from depths of up to two meters below the martian surface, where organics may be protected from degradation derived from cosmic radiation and/or oxidative chemical reactions. When combined with the complement of instruments in the rover's Pasteur Payload, MOMA has the potential to reveal the presence of a wide range of organics preserved in a variety of mineralogical environments, and to begin to understand the structural character and potential origin of those compounds. The MOMA investigation is led by the Max Planck Institute for Solar System Research (MPS) with the mass spectrometer subsystem provided by NASA GSFC. MOMA's linear ion trap mass spectrometer (ITMS) is designed to analyze molecular composition of: (i) gas evolved from pyrolyzed powder samples and separated in a gas chromatograph; and, (ii) ions directly desorbed from crushed solid samples at Mars ambient pressure, as enabled by a pulsed UV laser system, fast-actuating aperture valve and capillary ion inlet. Breadboard ITMS and associated electronics have been advanced to high end-to-end fidelity in preparation for flight hardware delivery to Germany in 2015.

  16. Linear ion-trap MSn with high resolution mass spectrometry reveals structural diversity of epidermal 1-O-acyl ceramide family in mouse epidermis.

    Science.gov (United States)

    Lin, Meei-Hua; Miner, Jeffery; Turk, John; Hsu, Fong-Fu

    2017-02-02

    1-O-acylceramide is a new class of epidermal ceramide found in humans and mice. Here, we report ESI linear ion-trap (LIT) multiple stage mass spectrometric (MSn) approach with high resolution towards structural characterization of this lipid family isolated from mice. Molecular species desorbed as the [M + H]+ ions was subjected to LIT MS2 to yield predominately the [M + H - H2O]+ ions, followed by MS3 to cleave the 1-O-acyl residue to yield the [M + H - H2O - (1-O-fatty acid)]+ ions. The structures of the N-acyl chain and long-chain base (LCB) of the molecule were determined by MS4 on ([M + H - H2O - (1-O-fatty acid)]+) ions that yielded multiple sets of specific ions. Using this approach, isomers varied in the 1-O-acyl (from 14:0- to 26:0-O-acyl) and N-acyl chains (from 20:0- to 26:0-N-acyl) with 18:1-sphingosine as the major LCB were found for the entire family. Minor isomers consisting of 16:1- 17:1-, 18:2-, and 19:1-sphingosine LCB, with odd fatty acyl chain, or with monounsaturated N- or O- fatty acyl substituents were also identified. An estimation of more than 700 1-O-acylceramide species, largely isobaric isomers are present, underscoring the complexity of this ceramide family.

  17. Identification of in vivo nitrosylated phytochelatins in Arabidopsis thaliana cells by liquid chromatography-direct electrospray-linear ion trap-mass spectrometry.

    Science.gov (United States)

    Elviri, L; Speroni, F; Careri, M; Mangia, A; di Toppi, L Sanità; Zottini, M

    2010-06-18

    Reversed-phase liquid chromatography (RPLC) and electrospray (ESI)-linear ion trap (LIT) mass spectrometry was applied to the direct characterization of in vivo S-nitrosylated (SNO) phytochelatins (PCs) expressed in cadmium-stressed Arabidopsis thaliana cells. Cys-nitrosylation is under discussion as in vivo redox-based post-translational modification of proteins and peptides in plants in which the -NO group is involved as signal molecule in different biological functions. The gas-phase ion chemistry of in vivo and in vitro generated SNO-PC(s) was compared with the aim of evaluating NO binding stability and improving MS knowledge about peptide nitrosation. Using RPLC separation and ESI-LIT-MS, mono-nitrosylated PCs were identified in in vivo cadmium treated A. thaliana cells without derivatization. The in vivo binding of the NO group to PC(2), PC(3) and PC(4) resulted to occur selectively on only one cystein residue. The fragmentation pathway energies of the in vitro GSNO-generated NO-PCs with respect to the in vivo NO-PCs were investigated, suggesting the presence of a different internal stability for these molecules. By carrying out MS(2) experiments on these quasi-symmetric peptides, the different stability degree of the NO group was demonstrated to be correlated with the PC chain length. In addition, the data obtained highlight a putative role of the adjacent Glu/Cys motif in the gas-phase stability of the NO-containing molecule.

  18. [Screening and confirmation of carcinogenic dyes in textiles by high performance liquid chromatography-linear ion trap/orbitrap high resolution mass spectrometry].

    Science.gov (United States)

    Xiu, Xiaoli; Luo, Xin; Niu, Zengyuan; Ye, Xiwen; Zhixu, Tang; Li, Jingying; Wang, Yongwei; Du, Wei

    2013-10-01

    A method of high performance liquid chromatography-linear ion trap/Orbitrap high resolution mass spectrometry (HPLC-LTQ/Orbitrap MS) was used to screen and confirm carcinogenic dyes in textiles. The analytes were extracted from textile samples with pyridine/water (1/1, v/v) in a water bath under controlled conditions (95 degrees C, 150 r/min), and then filtered with a 0.22 microm polytetrafluoroetylene (PTFE) membrane. The eluates were separated on a CAPCELL PAK C18 column (100 mm x 2.0 mm, 5 microm) using gradient elution with acetonitrile/ 5 mmol/L ammonium acetate aqueous solution containing 0.01% formic acid (in positive mode) and acetonitrile/5 mmol/L ammonium acetate aqueous solution (in negative mode), and finally detected by HPLC-LTQ/Orbitrap MS in ESI modes. Full scan experiments were performed over the range of m/z 200-800. The screening and quantitative analysis were carried out by the accurate mass of quasi-molecular ion and the peak area in extracted chromatogram with accurate mass, respectively. The confirmatory analysis for target compounds was performed with the retention time and qualitative fragments obtained by data-dependent scan mode. Under the optimal conditions, nine carcinogenic dyes were routinely detected with mass accuracy below 5 x 10(-6) (5 ppm), and good linearities were provided in their respective linear ranges with correlation coefficients higher than 0.99. The limits of detection were in the range of 0.125-25 mg/kg. The average recoveries at three spiked levels were in the range of 62.13%116.28% with the relative standard deviations (RSDs) lower than 15%. The proposed method was applied to screen and confirm the nine carcinogenic dyes in textile samples. It is convenient and reliable.

  19. Liquid Chromatography-Electrospray Quadrupole Linear Ion Trap Mass Spectrometric Method for Quantitation of Domperidone in Chinese Healthy Volunteers

    Institute of Scientific and Technical Information of China (English)

    WU Yi; CHU Yang; ZHANG Yun-hui; WU Dan; GU Jing-kai

    2007-01-01

    A rapid, sensitive, and accurate method based on LC/MS/MS was developed and validated for the determination of domperidone in human plasma. Domperidone and internal standard, tramadol, were extracted from plasma with diethyl ether-dichloromethane(60: 40, volume ratio) and separated by reversed-phase HPLC with methanol-water-ammonia solution(80: 20: 0.2, volume ratio) as the mobile phase. Detection was carried out via multiple-reaction monitoring(MRM) on a Q-trapTM LC/MS/MS system(Q-trapTM). The assay result was linear over a concentration range of 0.1-30 ng/mL with a limit of quantitation (LOQ) of 0.1 ng/mL. The inter- and intra-day precision levels were within 7.52% and 12. 9%, respectively, whereas the accuracy was within a range of 87. 3%-114%. This method has been successfully applied to evaluate the pharmacokinetics of domperidone in Chinese healthy volunteers given an oral dose of 10 mg.

  20. Metabolic profile of naringenin in the stomach and colon using liquid chromatography/electrospray ionization linear ion trap quadrupole-Orbitrap-mass spectrometry (LC-ESI-LTQ-Orbitrap-MS) and LC-ESI-MS/MS.

    Science.gov (United States)

    Orrego-Lagarón, Naiara; Vallverdú-Queralt, Anna; Martínez-Huélamo, Miriam; Lamuela-Raventos, Rosa M; Escribano-Ferrer, Elvira

    2016-02-20

    Several biological activities (antioxidant, anti-inflammatory, anticarcinogenic) are attributed to naringenin (NAR)-a predominant flavonoid of citrus fruit and tomato-despite its low bioavailability after ingestion. NAR undergoes extensive metabolism when crossing the gastrointestinal tract, resulting in enteric, hepatic and microbial metabolites, some of them with recognized beneficial effects on human health. This study sought to provide new insights into the metabolism of NAR in regions of the gastrointestinal tract where it has been less studied: the stomach and colon. With this purpose, liquid chromatography coupled with an electrospray ionization hybrid linear ion trap quadrupole Orbitrap mass spectrometry technique (LC-ESI-LTQ-Orbitrap-MS) was used for an accurate identification of NAR metabolites, and liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) on a triple quadrupole was used for their identification and quantification. The combination of both analytical techniques provided a broader metabolic profile of NAR. As far as we know, this is the first in-depth metabolic profiling study of NAR in the stomach of mice. Three of the metabolites determined using the LC-LTQ-Orbitrap could not be identified by LC-ESI-MS/MS in stomach perfusion samples: apigenin, 3-(4-hydroxyphenyl) propionic acid and phloroglucinol. The number of colonic metabolites determined using the LTQ-Orbitrap-MS was more than twice the number identified by LC-ESI-MS/MS.

  1. Simultaneous identification and quantification of tetrodotoxin in fresh pufferfish and pufferfish-based products using immunoaffinity columns and liquid chromatography/quadrupole-linear ion trap mass spectrometry

    Science.gov (United States)

    Guo, Mengmeng; Wu, Haiyan; Jiang, Tao; Tan, Zhijun; Zhao, Chunxia; Zheng, Guanchao; Li, Zhaoxin; Zhai, Yuxiu

    2016-08-01

    In this study, we established a comprehensive method for simultaneous identification and quantification of tetrodotoxin (TTX) in fresh pufferfish tissues and pufferfish-based products using liquid chromatography/quadrupole-linear ion trap mass spectrometry (LC-QqLIT-MS). TTX was extracted by 1% acetic acid-methanol, and most of the lipids were then removed by freezing lipid precipitation, followed by purification and concentration using immunoaffinity columns (IACs). Matrix effects were substantially reduced due to the high specificity of the IACs, and thus, background interference was avoided. Quantitation analysis was therefore performed using an external calibration curve with standards prepared in mobile phase. The method was evaluated by fortifying samples at 1, 10, and 100 ng/g, respectively, and the recoveries ranged from 75.8%-107%, with a relative standard deviation of less than 15%. The TTX calibration curves were linear over the range of 1-1 000 μg/L, with a detection limit of 0.3 ng/g and a quantification limit of 1 ng/g. Using this method, samples can be further analyzed using an information-dependent acquisition (IDA) experiment, in the positive mode, from a single liquid chromatography-tandem mass spectrometry injection, which can provide an extra level of confirmation by matching the full product ion spectra acquired for a standard sample with those from an enhanced product ion (EPI) library. The scheduled multiple reaction monitoring method enabled TTX to be screened for, and TTX was positively identified using the IDA and EPI spectra. This method was successfully applied to analyze a total of 206 samples of fresh pufferfish tissues and pufferfish-based products. The results from this study show that the proposed method can be used to quantify and identify TTX in a single run with excellent sensitivity and reproducibility, and is suitable for the analysis of complex matrix pufferfish samples.

  2. Simultaneous identification and quantification of tetrodotoxin in fresh pufferfish and pufferfish-based products using immunoaffinity columns and liquid chromatography/quadrupole-linear ion trap mass spectrometry

    Science.gov (United States)

    Guo, Mengmeng; Wu, Haiyan; Jiang, Tao; Tan, Zhijun; Zhao, Chunxia; Zheng, Guanchao; Li, Zhaoxin; Zhai, Yuxiu

    2017-07-01

    In this study, we established a comprehensive method for simultaneous identification and quantification of tetrodotoxin (TTX) in fresh pufferfish tissues and pufferfish-based products using liquid chromatography/quadrupole-linear ion trap mass spectrometry (LC-QqLIT-MS). TTX was extracted by 1% acetic acid-methanol, and most of the lipids were then removed by freezing lipid precipitation, followed by purification and concentration using immunoaffinity columns (IACs). Matrix effects were substantially reduced due to the high specificity of the IACs, and thus, background interference was avoided. Quantitation analysis was therefore performed using an external calibration curve with standards prepared in mobile phase. The method was evaluated by fortifying samples at 1, 10, and 100 ng/g, respectively, and the recoveries ranged from 75.8%-107%, with a relative standard deviation of less than 15%. The TTX calibration curves were linear over the range of 1-1 000 μg/L, with a detection limit of 0.3 ng/g and a quantification limit of 1 ng/g. Using this method, samples can be further analyzed using an information-dependent acquisition (IDA) experiment, in the positive mode, from a single liquid chromatography-tandem mass spectrometry injection, which can provide an extra level of confirmation by matching the full product ion spectra acquired for a standard sample with those from an enhanced product ion (EPI) library. The scheduled multiple reaction monitoring method enabled TTX to be screened for, and TTX was positively identified using the IDA and EPI spectra. This method was successfully applied to analyze a total of 206 samples of fresh pufferfish tissues and pufferfish-based products. The results from this study show that the proposed method can be used to quantify and identify TTX in a single run with excellent sensitivity and reproducibility, and is suitable for the analysis of complex matrix pufferfish samples.

  3. Trace level determination of beta-blockers in waste waters by highly selective molecularly imprinted polymers extraction followed by liquid chromatography-quadrupole-linear ion trap mass spectrometry.

    Science.gov (United States)

    Gros, Meritxell; Pizzolato, Tânia-Mara; Petrović, Mira; de Alda, Maria José López; Barceló, Damià

    2008-05-02

    This paper describes the development of an analytical methodology to determine eight beta-blockers in waste waters using molecularly imprinted polymers (MIPs) as extraction and pre-concentration material, followed by liquid chromatography-quadrupole-linear ion trap mass spectrometry (LC-QqLIT MS). The advantages offered by MIPs, in terms of selectivity and specificity, were compared with the most commonly polymeric materials used (the lipophilic-hydrophilic balanced Oasis HLB cartridges). Even though recoveries achieved with both sorbents were similar, ranging from 50 to 110% for sewage treatment plant (STP) effluent and 40-110 for STP influent, respectively, MIPs provided lower method detection limits than Oasis HLB, due to their specificity for target analytes and closely related analogues. Method detection limits (MDL) achieved using MIPs ranged from 0.2 to 6.4 ng/L for STP effluent and from 0.4 to 6.5 ng/L for STP influent. To highlight the advantages of MIPs against conventional polymeric cartridges, a detailed matrix effects study as well as cross reactivity tests were performed. For the latter purpose, the extraction efficiency of some pharmaceuticals and pesticides belonging to different therapeutic classes was assessed. LC-QqLIT MS, used for quantification and confirmation, proved to be a powerful analytical tool, as instrumental detection limits (IDL) achieved ranged from 0.2 to 2.7 pg injected (in multiple reaction monitoring mode (MRM)). In addition the inclusion of high sensitive MS/MS scans for each compound when working in Information Dependent Acquisition mode (IDA) provided extra confirmation for unequivocal identification of target compounds in complex environmental matrices.

  4. Screening for DNA adducts by data-dependent constant neutral loss-triple stage mass spectrometry with a linear quadrupole ion trap mass spectrometer.

    Science.gov (United States)

    Bessette, Erin E; Goodenough, Angela K; Langouët, Sophie; Yasa, Isil; Kozekov, Ivan D; Spivack, Simon D; Turesky, Robert J

    2009-01-15

    A two-dimensional linear quadrupole ion trap mass spectrometer (LIT/MS) was employed to simultaneously screen for DNA adducts of environmental, dietary, and endogenous genotoxicants, by data-dependent constant neutral loss scanning followed by triple-stage mass spectrometry (CNL-MS3). The loss of the deoxyribose (dR) from the protonated DNA adducts ([M + H - 116]+) in the MS/MS scan mode triggered the acquisition of MS3 product ion spectra of the aglycone adducts [BH2]+. Five DNA adducts of the tobacco carcinogen 4-aminobiphenyl (4-ABP) were detected in human hepatocytes treated with 4-ABP, and three DNA adducts of the cooked-meat carcinogen 2-amino-3,8-dimethylimidazo[4,5-f]quinoxaline (MeIQx) were identified in the livers of rats exposed to MeIQx, by the CNL-MS3 scan mode. Buccal cell DNA from tobacco smokers was screened for DNA adducts of various classes of carcinogens in tobacco smoke including 4-ABP, 2-amino-9H-pyrido[2,3-b]indole (AalphaC), and benzo[a]pyrene (BaP); the cooked-meat carcinogens MeIQx, AalphaC, and 2-amino-1-methyl-6-phenylmidazo[4,5-b]pyridine (PhIP); and the lipid peroxidation products acrolein (AC) and trans-4-hydroxynonenal (HNE). The CNL-MS3 scanning technique can be used to simultaneously screen for multiple DNA adducts derived from different classes of carcinogens, at levels of adduct modification approaching 1 adduct per 108 unmodified DNA bases, when 10 microg of DNA is employed for the assay.

  5. Quantification of Lansoprazole in Oral Suspension by Ultra-High-Performance Liquid Chromatography Hybrid Ion-Trap Time-of-Flight Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Stacy D. Brown

    2011-01-01

    Full Text Available An LC-MS/MS method was developed and validated to be used as a stability indicating assay for the study of a 3 mg/mL lansoprazole oral suspension. The method utilizes a UPLC (ultra-performance liquid chromatography column and unique mass spectrometric detection (ion-trap time-of-flight (IT-TOF to achieve a sensitive (LOD 2 ng/mL, accurate, and reproducible quantification of lansoprazole. This method reports an intraday and interday coefficient of variation of 2.98 ± 2.17% (n=5 for each concentration for each day and 3.07 ± 0.89% (n=20 for each concentration, respectively. Calibration curves (5–25 μg/mL were found to be linear with an R2 value ranging from 0.9972 to 0.9991 on 4 different days. Accuracy of the assay, expressed as % error, ranged from 0.30 to 5.22%. This method is useful for monitoring the stability of lansoprazole in oral suspension.

  6. Comparison of two ionic liquid dispersive liquid-liquid microextraction approaches for the determination of benzoylurea insecticides in wastewater using liquid chromatography-quadrupole-linear ion trap-mass spectrometry: evaluation of green parameters.

    Science.gov (United States)

    Vázquez, M M Parrilla; Vázquez, P Parrilla; Galera, M Martínez; Moreno, A Uclés

    2014-08-22

    Two dispersive liquid-liquid microextraction (DLLME) approaches including temperature-controlled ionic liquid dispersive liquid-liquid microextraction (TCIL-DLLME) and ultrasound-assisted ionic liquid dispersive liquid-liquid microextraction (US-IL-DLLME) were compared for the extraction of six benzoylurea insecticides (diflubenzuron, triflumuron, hexaflumuron, teflubenzuron, lufenuron and flufenoxuron) from wastewater samples prior to their determination by high-performance liquid chromatography with a hybrid triple quadrupole-linear ion trap-mass spectrometer (LC-QqLIT-MS/MS). Influential parameters affecting extraction efficiency were systematically studied and optimized and the most significant green parameters were quantified and compared. The best results were obtained using the US-IL-DLLME procedure, which employed the IL 1-octyl-3-methylimidazolium hexafluorophosphate ([C8MIM][PF6]) and methanol (MeOH) as extraction and disperser solvent, respectively. US-IL-DLLME procedure was fast, easy, low environmental toxicity and, it was also able to successfully extract all selected benzoylureas. This method was extensively validated with satisfactory results: limits of detection and quantification were in the range 0.5-1.0 ng L(-1) and 1.5-3.5 ng L(-1), respectively, whereas recovery rates ranged from 89 to 103% and the relative standard deviations were lower than 13.4%. The applicability of the method was assessed with the analysis of effluent wastewater samples from a wastewater treatment plant located in an agricultural zone of Almería (Spain) and the results indicated the presence of teflubenzuron at mean concentration levels of 11.3 ng L(-1). US-IL-DLLME sample treatment in combination with LC-QqLIT-MS/MS has demonstrated to be a sensitive, selective and efficient method to determine benzoylurea insecticides in wastewaters at ultra-trace levels.

  7. Resonance methods in quadrupole ion traps

    Science.gov (United States)

    Snyder, Dalton T.; Peng, Wen-Ping; Cooks, R. Graham

    2017-01-01

    The quadrupole ion trap is widely used in the chemical physics community for making measurements on dynamical systems, both intramolecular (e.g. ion fragmentation reactions) and intermolecular (e.g. ion/molecule reactions). In this review, we discuss linear and nonlinear resonances in quadrupole ion traps, an understanding of which is critical for operation of these devices and interpretation of the data which they provide. The effect of quadrupole field nonlinearity is addressed, with important implications for promoting fragmentation and achieving unique methods of mass scanning. Methods that depend on ion resonances (i.e. matching an external perturbation with an ion's induced frequency of motion) are discussed, including ion isolation, ion activation, and ion ejection.

  8. Design and Testing of a Linear Ion Trap for the Mars Organic Molecule Analyzer (MOMA) Investigation on the 2018 ExoMars Rover

    Science.gov (United States)

    Brinckerhoff, W. B.; van Amerom, F.; Danell, R.; Pinnick, V. T.; Arevalo, R. D.; Li, X.; Hovmand, L.; Siljestrom, S.; Mahaffy, P. R.; Goetz, W.; Goesmann, F.; Steininger, H.

    2013-12-01

    The 2018 ExoMars rover mission includes the Mars Organic Molecule Analyzer (MOMA) investigation. MOMA will examine the chemical composition of samples acquired from depths of up to two meters below the martian surface, where organics may be protected from radiative and oxidative degradation. When combined with the complement of instruments in the rover's Pasteur Payload, MOMA has the potential to reveal the presence of a wide range of organics preserved in a variety of mineralogical environments, and to begin to understand the structural character and potential origin of those compounds. MOMA includes an ion trap mass spectrometer (ITMS) that is designed to analyze molecular composition of (i) gas evolved from pyrolyzed powder samples and separated on a gas chromatograph and (ii) ions directly desorbed from solid samples at Mars ambient pressure using a pulsed laser and a fast-valve capillary ion inlet system. This 'dual source' approach gives MOMA unprecedented breadth of detection over a wide range of molecular weights and volatilities. Analysis of nonvolatile, higher-molecular weight organics such as carboxylic acids and peptides even in the presence of significant perchlorate concentrations is enabled by the extremely short (~1 ns) pulses of the desorption laser. Use of the ion trap's tandem mass spectrometry mode permits selective focus on key species for isolation and controlled fragmentation, providing structural analysis capabilities. The flight-like engineering test unit (ETU) of the ITMS, now under construction, will be used to verify breadboard performance with high fidelity, while simultaneously supporting the development of analytical scripts and spectral libraries using synthetic and natural Mars analog samples guided by current results from MSL. ETU campaign data will strongly advise the specifics of the calibration applied to the MOMA flight model as well as the science operational procedures during the mission.

  9. Quantum Games in ion traps

    Energy Technology Data Exchange (ETDEWEB)

    Buluta, Iulia Maria [Department of Quantum Engineering and Systems Science, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan)]. E-mail: noa@lyman.q.t.u-tokyo.ac.jp; Fujiwara, Shingo [Department of Quantum Engineering and Systems Science, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan)]. E-mail: fujiwara@lyman.q.t.u-tokyo.ac.jp; Hasegawa, Shuichi [Department of Quantum Engineering and Systems Science, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan)]. E-mail: hasegawa@q.t.u-tokyo.ac.jp

    2006-10-09

    We propose a general, scalable framework for implementing two-choices-multiplayer Quantum Games in ion traps. In particular, we discuss two famous examples: the Quantum Prisoners' Dilemma and the Quantum Minority Game. An analysis of decoherence due to intensity fluctuations in the applied laser fields is also provided.

  10. Scaling ion traps for quantum computing

    CSIR Research Space (South Africa)

    Uys, H

    2010-09-01

    Full Text Available The design, fabrication and preliminary testing of a chipscale, multi-zone, surface electrode ion trap is reported. The modular design and fabrication techniques used are anticipated to advance scalability of ion trap quantum computing architectures...

  11. Nanofriction in cold ion traps.

    Science.gov (United States)

    Benassi, A; Vanossi, A; Tosatti, E

    2011-01-01

    Sliding friction between crystal lattices and the physics of cold ion traps are so far non-overlapping fields. Two sliding lattices may either stick and show static friction or slip with dynamic friction; cold ions are known to form static chains, helices or clusters, depending on the trapping conditions. Here we show, based on simulations, that much could be learnt about friction by sliding, through, for example, an electric field, the trapped ion chains over a corrugated potential. Unlike infinite chains, in which the theoretically predicted Aubry transition to free sliding may take place, trapped chains are always pinned. Yet, a properly defined static friction still vanishes Aubry-like at a symmetric-asymmetric structural transition, found for decreasing corrugation in both straight and zig-zag trapped chains. Dynamic friction is also accessible in ringdown oscillations of the ion trap. Long theorized static and dynamic one-dimensional friction phenomena could thus become accessible in future cold ion tribology.

  12. Trapping Mode Dipolar DC Collisional Activation in the RF-Only Ion Guide of a Linear Ion Trap/Time-of-Flight Instrument for Gaseous Bio-Ion Declustering

    Science.gov (United States)

    Webb, Ian K.; Gao, Yang; Londry, Frank A.; McLuckey, Scott A.

    2013-01-01

    The application of dipolar DC (DDC) to the RF-only ion guide (Q0) of a hybrid quadrupole/time-of-flight (QqTOF) mass spectrometer for collision-induced declustering of large bio-ions is described. As a broadband technique, ion trap DDC collision activation (CA) is employed to decluster ions simultaneously over a relatively broad mass-to-charge range. Declustering DDC CA can yield significantly narrower peaks relative to those observed in the absence of declustering methods, depending upon the extent of non-covalent adduction associated with the ions, and can also be used in conjunction with other methods, such as nozzle-skimmer collisional activation. The key experimental variables in the DDC experiment are the dipolar DC voltage (VDDC), VRF, and the time over which VDDC is applied. The VDDC/VRF ratio is key to the extent to which ion temperatures are elevated and also influences the upper mass-to-charge limit for ion storage. The VDDC/VRF ratio affects ion temperatures and upper m/z limit in opposing directions. That is, as the ratio increases, ion temperature increases whereas the upper m/z storage limit decreases. However, for a given VDDC/VRF ratio, the upper m/z storage limit can be increased by increasing VRF, at the expense of the lower m/z limit for ion storage. The key value of the approach is that it affords a relatively precise degree of control over ion temperatures as well as the time over which they are elevated to the higher temperature. The utility of the method is illustrated by the application of ion trap DDC CA in Q0 to oligonucleotide, protein, and multimeric protein complex analyte ions. PMID:24078247

  13. Cryogenic silicon surface ion trap

    CERN Document Server

    Niedermayr, Michael; Kumph, Muir; Partel, Stefan; Edlinger, Johannes; Brownnutt, Michael; Blatt, Rainer

    2014-01-01

    Trapped ions are pre-eminent candidates for building quantum information processors and quantum simulators. They have been used to demonstrate quantum gates and algorithms, quantum error correction, and basic quantum simulations. However, to realise the full potential of such systems and make scalable trapped-ion quantum computing a reality, there exist a number of practical problems which must be solved. These include tackling the observed high ion-heating rates and creating scalable trap structures which can be simply and reliably produced. Here, we report on cryogenically operated silicon ion traps which can be rapidly and easily fabricated using standard semiconductor technologies. Single $^{40}$Ca$^+$ ions have been trapped and used to characterize the trap operation. Long ion lifetimes were observed with the traps exhibiting heating rates as low as $\\dot{\\bar{n}}=$ 0.33 phonons/s at an ion-electrode distance of 230 $\\mu$m. These results open many new avenues to arrays of micro-fabricated ion traps.

  14. Ion trapping for quantum information processing

    Institute of Scientific and Technical Information of China (English)

    WAN Jin-yin; WANG Yu-zhu; LIU Liang

    2007-01-01

    In this paper we have reviewed the recent pro-gresses on the ion trapping for quantum information process-ing and quantum computation. We have first discussed the basic principle of quantum information theory and then fo-cused on ion trapping for quantum information processing.Many variations, especially the techniques of ion chips, have been investigated since the original ion trap quantum compu-tation scheme was proposed. Full two-dimensional control of multiple ions on an ion chip is promising for the realization of scalable ion trap quantum computation and the implemen-tation of quantum networks.

  15. Multiresidue analysis of 36 pesticides in soil using a modified quick, easy, cheap, effective, rugged, and safe method by liquid chromatography with tandem quadruple linear ion trap mass spectrometry.

    Science.gov (United States)

    Feng, Xue; He, Zeying; Wang, Lu; Peng, Yi; Luo, Ming; Liu, Xiaowei

    2015-09-01

    A new method for simultaneous determination of 36 pesticides, including 15 organophosphorus, six carbamate, and some other pesticides in soil was developed by liquid chromatography with tandem quadruple linear ion trap mass spectrometry. The extraction and clean-up steps were optimized based on the quick, easy, cheap, effective, rugged, and safe method. The data were acquired in multiple reaction monitoring mode combined with enhanced product ion to increase confidence of the analytical results. Validation experiments were performed in soil samples. The average recoveries of pesticides at four spiking levels (1, 5, 50, and 100 μg/kg) ranged from 63 to 126% with relative standard deviation below 20%. The limits of detection of pesticides were 0.04-0.8 μg/kg, and the limits of quantification were 0.1-2.6 μg/kg. The correlation coefficients (r(2) ) were higher than 0.990 in the linearity range of 0.5-200 μg/L for most of the pesticides. The method allowed for the analysis of the target pesticides in the lower μg/kg concentration range. The optimized method was then applied to the test of real soil samples obtained from several areas in China, confirming the feasibility of the method.

  16. Wide-scope screening and quantification of 50 pesticides in wine by liquid chromatography/quadrupole time-of-flight mass spectrometry combined with liquid chromatography/quadrupole linear ion trap mass spectrometry.

    Science.gov (United States)

    He, Zeying; Xu, Yaping; Wang, Lu; Peng, Yi; Luo, Ming; Cheng, Haiyan; Liu, Xiaowei

    2016-04-01

    In this paper, a wide scope screening method of pesticides in wine was established using liquid chromatography/quadrupole time-of-flight mass spectrometry (LC-QTOF MS) and liquid chromatography/quadrupole linear ion trap mass spectrometry (LC-QqLIT MS). Information dependent acquisition (IDA) experiments are used to obtain both MS and MS/MS information for LC-QTOF MS analysis. For LC-QqLIT MS analysis, MS/MS spectra of target pesticides were simultaneously acquired using Enhanced Product Ion (EPI) mode at very low concentrations to increase the confidence in analytical results of multiple reaction monitoring (MRM) by library searching. Method validation was carried out using 50 pesticides commonly used in vineyards. The LOQs, linearity, repeatability were determined and good enough for quantification. The screening and quantification results obtained using LC-QTOF MS and LC-QqLIT MS were compared. Contaminants were screened against libraries containing over 2800 compounds based on accurate mass, isotopic patterns, and MS/MS spectra searching to extend the scope of this methodology to non-target screening.

  17. Quantitation of isobaric phosphatidylcholine species in human plasma using a hybrid quadrupole linear ion trap mass spectrometer

    Science.gov (United States)

    Phosphatidylcholine (PC) species in human plasma are used as biomarkers of disease. PC biomarkers are often limited by the inability to separate isobaric PC. In this work, we developed a targeted shotgun approach for analysis of isobaric and isomeric PC. This approach is comprised of two mass spectr...

  18. Cooling effect of different buffer gas of trapped mercury ions in a linear ion trap%线型离子阱中不同缓冲气体对汞离子的冷却效果研究

    Institute of Scientific and Technical Information of China (English)

    杨玉娜; 柳浩; 何跃宏; 陈义和; 佘磊; 李交美

    2012-01-01

    Buffer gas cooling is the most effective and practical method to cool ions in ion trap.The kind and quantity of buffer gas are the key technologies in mercury ion microwave frequency standard experiments.Buffer gas made of helium,neon or argon was studied to cool trapped mercury ions (199Hg+)in a linear ion trap by introducing a resistance term in Mathieu's equation.It's found that the decay time of motion of 199Hg+ in argon gas is the shortest,and the frequency shift of the clock transition (40.5 GHz)is minimum when the pressure of helium is 10-5 Torr or the pressure of neon gas is 2.4 x 10-5 Torr.Neon is the most suitable buffer gas among helium,neon and argon,considering the decay time-constant of motion of 199Hg+ in buffer gases and 199Hg+ clock transition shift's sensitivity to the change of the pressure of buffer gas.%缓冲气体冷却是将离子阱中的离子云冷却的最有效和实用的方法,缓冲气体的种类和数量是汞离子微波频标实验的关键技术.通过在马修方程中引入阻力项的方法,研究了线型离子阱中氦气、氖气、氩气对囚禁的汞离子的冷却效果,结果表明在氩气中汞离子运动的衰减时间最短.研究了为使钟跃迁(40.5 GHz)的频率移动最小,所需氦气的压强为10-5 Torr,氖气的压强为2.4×10-5 Torr.考虑到缓冲气体对汞离子的冷却效率和对气体压强的敏感性,氖气要比氦气、氩气更适合作缓冲气体.

  19. Metabolism studies of the Kratom alkaloids mitraciliatine and isopaynantheine, diastereomers of the main alkaloids mitragynine and paynantheine, in rat and human urine using liquid chromatography-linear ion trap-mass spectrometry.

    Science.gov (United States)

    Philipp, Anika A; Wissenbach, Dirk K; Weber, Armin A; Zapp, Josef; Maurer, Hans H

    2011-05-01

    Mitragyna speciosa (Kratom in Thai), native in Southeast Asia, is increasingly misused as a herbal drug of abuse. During metabolism studies on the Kratom alkaloids mitragynine, its diastereomers speciogynine and speciociliatine as well as paynantheine in rats and humans, further isomeric compounds were detected in Kratom users' urine. The question arose whether these compounds were formed from the low abundant, isomeric alkaloids mitraciliatine (MC) and isopaynantheine (ISO-PAY). Therefore, the aim of the presented study was to identify using liquid chromatography-linear ion trap-mass spectrometry their phase I and II metabolites in rat urine after administration of pure MC or ISO-PAY, to confirm their formation in humans, and finally to confirm whether the above-mentioned isomeric compounds in human urine represent MC and ISO-PAY and/or their metabolites. The metabolic pathways of both alkaloids in rats were found to be comparable to those of their corresponding diastereomers. In the human urines tested, not all metabolites found in rats could be detected because of the much lower amounts of MC and ISO-PAY in Kratom. However, all the above-mentioned so far unknown isomeric compounds could be identified in the human urine samples as MC, ISO-PAY and/or their metabolites. The used LC separation was also suitable for the differentiation of all other Kratom alkaloids and their metabolites in human urine.

  20. Determination of sulfonamide antibiotics and metabolites in liver, muscle and kidney samples by pressurized liquid extraction or ultrasound-assisted extraction followed by liquid chromatography-quadrupole linear ion trap-tandem mass spectrometry (HPLC-QqLIT-MS/MS).

    Science.gov (United States)

    Hoff, Rodrigo Barcellos; Pizzolato, Tânia Mara; Peralba, Maria do Carmo Ruaro; Díaz-Cruz, M Silvia; Barceló, Damià

    2015-03-01

    Sulfonamides are widely used in human and veterinary medicine. The presence of sulfonamides residues in food is an issue of great concern. Throughout the present work, a method for the targeted analysis of 16 sulfonamides and metabolites residue in liver of several species has been developed and validated. Extraction and clean-up has been statistically optimized using central composite design experiments. Two extraction methods have been developed, validated and compared: i) pressurized liquid extraction, in which samples were defatted with hexane and subsequently extracted with acetonitrile and ii) ultrasound-assisted extraction with acetonitrile and further liquid-liquid extraction with hexane. Extracts have been analyzed by liquid chromatography-quadrupole linear ion trap-tandem mass spectrometry. Validation procedure has been based on the Commission Decision 2002/657/EC and included the assessment of parameters such as decision limit (CCα), detection capability (CCβ), sensitivity, selectivity, accuracy and precision. Method׳s performance has been satisfactory, with CCα values within the range of 111.2-161.4 µg kg(-1), limits of detection of 10 µg kg(-1) and accuracy values around 100% for all compounds.

  1. A strategy for comprehensive identification of sequential constituents using ultra-high-performance liquid chromatography coupled with linear ion trap-Orbitrap mass spectrometer, application study on chlorogenic acids in Flos Lonicerae Japonicae.

    Science.gov (United States)

    Zhang, Jia-yu; Wang, Zi-jian; Li, Yun; Liu, Ying; Cai, Wei; Li, Chen; Lu, Jian-qiu; Qiao, Yan-jiang

    2016-01-15

    The analytical methodologies for evaluation of multi-component system in traditional Chinese medicines (TCMs) have been inadequate or unacceptable. As a result, the unclarity of multi-component hinders the sufficient interpretation of their bioactivities. In this paper, an ultra-high-performance liquid chromatography coupled with linear ion trap-Orbitrap (UPLC-LTQ-Orbitrap)-based strategy focused on the comprehensive identification of TCM sequential constituents was developed. The strategy was characterized by molecular design, multiple ion monitoring (MIM), targeted database hits and mass spectral trees similarity filter (MTSF), and even more isomerism discrimination. It was successfully applied in the HRMS data-acquisition and processing of chlorogenic acids (CGAs) in Flos Lonicerae Japonicae (FLJ), and a total of 115 chromatographic peaks attributed to 18 categories were characterized, allowing a comprehensive revelation of CGAs in FLJ for the first time. This demonstrated that MIM based on molecular design could improve the efficiency to trigger MS/MS fragmentation reactions. Targeted database hits and MTSF searching greatly facilitated the processing of extremely large information data. Besides, the introduction of diagnostic product ions (DPIs) discrimination, ClogP analysis, and molecular simulation, raised the efficiency and accuracy to characterize sequential constituents especially position and geometric isomers. In conclusion, the results expanded our understanding on CGAs in FLJ, and the strategy could be exemplary for future research on the comprehensive identification of sequential constituents in TCMs. Meanwhile, it may propose a novel idea for analyzing sequential constituents, and is promising for quality control and evaluation of TCMs.

  2. Optical cavity integrated surface ion trap for enhanced light collection

    Science.gov (United States)

    Benito, Francisco M.

    Ion trap systems allow the faithful storage and manipulation of qubits encoded in the energy levels of the ions, and can be interfaced with photonic qubits that can be transmitted to connect remote quantum systems. Single photons transmitted from two remote sites, each entangled with one quantum memory, can be used to entangle distant quantum memories by interfering on a beam splitter. Efficient remote entanglement generation relies upon efficient light collection from single ions into a single mode fiber. This can be realized by integrating an ion trap with an optical cavity and employing the Purcell effect for enhancing the light collection. Remote entanglement can be used as a resource for a quantum repeater for provably secure long-distance communication or as a method for communicating within a distributed quantum information processor. We present the integration of a 1 mm optical cavity with a micro-fabricated surface ion trap. The plano-concave cavity is oriented normal to the chip surface where the planar mirror is attached underneath the trap chip. The cavity is locked using a 780 nm laser which is stabilized to Rubidium and shifted to match the 369 nm Doppler transition in Ytterbium. The linear ion trap allows ions to be shuttled in and out of the cavity mode. The Purcell enhancement of spontaneous emission into the cavity mode would then allow efficient collection of the emitted photons, enabling faster remote entanglement generation.

  3. Oxford ion-trap quantum computing project.

    Science.gov (United States)

    Lucas, D M; Donald, C J S; Home, J P; McDonnell, M J; Ramos, A; Stacey, D N; Stacey, J-P; Steane, A M; Webster, S C

    2003-07-15

    We describe recent progress in the development of an ion-trap quantum information processor. We discuss the choice of ion species and describe recent experiments on read-out for a ground-state qubit and photoionization trap loading.

  4. Use of liquid chromatography coupled to low- and high-resolution linear ion trap mass spectrometry for studying the metabolism of paynantheine, an alkaloid of the herbal drug Kratom in rat and human urine.

    Science.gov (United States)

    Philipp, Anika A; Wissenbach, Dirk K; Weber, Armin A; Zapp, Josef; Zoerntlein, Siegfried W; Kanogsunthornrat, Jidapha; Maurer, Hans H

    2010-04-01

    The Thai medicinal plant Mitragyna speciosa (Kratom in Thai) is misused as a herbal drug of abuse. During studies on the main Kratom alkaloid mitragynine (MG) in rats and humans, several dehydro analogs could be detected in urine of Kratom users, which were not found in rat urine after administration of pure MG. Questions arose as to whether these compounds are formed from MG only by humans or whether they are metabolites formed from the second abundant Kratom alkaloid paynantheine (PAY), the dehydro analog of MG. Therefore, the aim of the presented study was to identify the phase I and II metabolites of PAY in rat urine after administration of the pure alkaloid. This was first isolated from Kratom leaves. Liquid chromatography-linear ion trap mass spectrometry provided detailed structure information of the metabolites in the MS(n) mode particularly with high resolution. Besides PAY, the following phase I metabolites could be identified: 9-O-demethyl PAY, 16-carboxy PAY, 9-O-demethyl-16-carboxy PAY, 17-O-demethyl PAY, 17-O-demethyl-16,17-dihydro PAY, 9,17-O-bisdemethyl PAY, 9,17-O-bisdemethyl-16,17-dihydro PAY, 17-carboxy-16,17-dihydro PAY, and 9-O-demethyl-17-carboxy-16,17-dihydro PAY. These metabolites indicated that PAY was metabolized via the same pathways as MG. Several metabolites were excreted as glucuronides or sulfates. The metabolism studies in rats showed that PAY and its metabolites corresponded to the MG-related dehydro compounds detected in urine of the Kratom users. In conclusion, PAY and its metabolites may be further markers for a Kratom abuse in addition of MG and its metabolites.

  5. Structural Definition of Trehalose 6-Monomycolates and Trehalose 6,6'-Dimycolates from the Pathogen Rhodococcus equi by Multiple-Stage Linear Ion-Trap Mass Spectrometry with Electrospray Ionization

    Science.gov (United States)

    Hsu, Fong-Fu; Wohlmann, Jens; Turk, John; Haas, Albert

    2011-12-01

    The cell wall of the pathogenic bacterium Rhodococcus equi ( R. equi) contains abundant trehalose monomycolate (TMM) and trehalose dimycolate (TDM), the glycolipids bearing mycolic acids. Here, we describe multiple-stage (MS n ) linear ion-trap (LIT) mass spectrometric approaches toward structural characterization of TMM and TDM desorbed as [M + Alk]+ (Alk = Na, Li) and as [M + X]- (X = CH3CO2, HCO2) ions by electrospray ionization (ESI). Upon MS n ( n = 2, 3, 4) on the [M + Alk]+ or the [M + X]- adduct ions of TMM and TDM, abundant structurally informative fragment ions are readily available, permitting fast assignment of the length of the meromycolate chain and of the α-branch on the mycolyl residues. In this way, structures of TMM and TDM isolated from pathogenic R. equi strain 103 can be determined. Our results indicate that the major TMM and TDM molecules possess 6, and/or 6'-mycolyl groups that consist of mainly C14 and C16 α-branches with meromycolate branches ranging from C18 to C28, similar to the structures of the unbound mycolic acids found in the cell envelope. Up to 60 isobaric isomers varying in chain length of the α-branch and of the meromycolate backbone were observed for some of the TDM species in the mixture. This mass spectrometric approach provides a direct method that affords identification of various TMM and TDM isomers in a mixture of which the complexity of this lipid class has not been previously reported using other analytical methods.

  6. Application of a hybrid ordered mesoporous silica as sorbent for solid-phase multi-residue extraction of veterinary drugs in meat by ultra-high-performance liquid chromatography coupled to ion-trap tandem mass spectrometry.

    Science.gov (United States)

    Casado, Natalia; Morante-Zarcero, Sonia; Pérez-Quintanilla, Damián; Sierra, Isabel

    2016-08-12

    A quick, sensitive and selective analytical reversed-phase multi-residue method using ultra-high performance liquid chromatography coupled to an ion-trap mass spectrometry detector (UHPLC-IT-MS/MS) operating in both positive and negative ion mode was developed for the simultaneous determination of 23 veterinary drug residues (β-blockers, β-agonists and Non-Steroidal Anti-inflammatory Drugs (NSAIDs)) in meat samples. The sample treatment involved a liquid-solid extraction followed by a solid-phase extraction (SPE) procedure. SBA-15 type mesoporous silica was synthetized and modified with octadecylsilane, and the resulting hybrid material (denoted as SBA-15-C18) was applied and evaluated as SPE sorbent in the purification of samples. The materials were comprehensively characterized, and they showed a high surface area, high pore volume and a homogeneous distribution of the pores. Chromatographic conditions and extraction procedure were optimized, and the method was validated according to the Commission Decision 2002/657/EC. The method detection limits (MDLs) and the method quantification limits (MQLs) were determined for all the analytes in meat samples and found to range between 0.01-18.75μg/kg and 0.02-62.50μg/kg, respectively. Recoveries for 15 of the target analytes ranged from 71 to 98%. In addition, for comparative purpose SBA-15-C18 was evaluated towards commercial C18 amorphous silica. Results revealed that SBA-15-C18 was clearly more successful in the multi-residue extraction of the 23 mentioned analytes with higher recovery values. The method was successfully tested to analyze prepacked preparations of mince bovine meat. Traces of propranolol, ketoprofen and diclofenac were detected in some samples.

  7. Optimization of RF multipole ion trap geometries

    Science.gov (United States)

    Fanghänel, Sven; Asvany, Oskar; Schlemmer, Stephan

    2017-02-01

    Radio-frequency (rf) traps are ideal places to store cold ions for spectroscopic experiments. Specific multipole configurations are suited best for different applications but have to be modified to allow e.g. for a proper overlap of a laser beam waist with the ion cloud. Therefore the corresponding trapping fields should be shaped accordingly. To achieve this goal highly accurate electrical potentials of rf multipole traps and the resulting effective trapping potentials are calculated using the boundary element method (BEM). These calculations are used to evaluate imperfections and to optimize the field geometry. For that purpose the complex fields are reduced to a small set of multipole expansion coefficients. Desirable values for these coefficients are met by systematic changes of real trap dimensions from CAD designs. The effect of misalignment of a linear quadrupole, the optimization of an optically open Paul trap, the influence of steering electrodes (end electrode and ring electrode) on a 22-pole ion trap and the effect of the micro motion on the lowest reachable temperatures in such a trap are discussed.

  8. Simultaneous determination of 19 triazine pesticides and degradation products in processed cereal samples from Chinese total diet study by isotope dilution–high performance liquid chromatography–linear ion trap mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Li, Peng [College of Veterinary Medicine, China Agricultural University, Beijing 100193 (China); China National Center for Food Safety Risk Assessment, Beijing 100021 (China); Yang, Xin, E-mail: beijing-yangxin@163.com [China National Center for Food Safety Risk Assessment, Beijing 100021 (China); Miao, Hong; Zhao, Yunfeng [China National Center for Food Safety Risk Assessment, Beijing 100021 (China); Key Lab of Food Safety Risk Assessment, Ministry of Health, Beijing 100021 (China); Liu, Wei [Shandong Province Environmental Monitoring Centre, Jinan 250013 (China); Wu, Yongning, E-mail: china_cdc@yahoo.cn [College of Veterinary Medicine, China Agricultural University, Beijing 100193 (China); China National Center for Food Safety Risk Assessment, Beijing 100021 (China); Key Lab of Food Safety Risk Assessment, Ministry of Health, Beijing 100021 (China)

    2013-06-05

    Graphical abstract: -- Highlights: •19 triazines were determined in cereal samples from Chinese TDS for the first time. •Isotope dilution technique and HPLC–LIT-MS{sup 3} method are both applied in this study. •CCαs and CCβs are much lower in this work than those of the previous publications. -- Abstract: A selective and sensitive isotope dilution–high performance liquid chromatography–linear ion trap mass spectrometry (Isotope Dilution–HPLC–LIT-MS{sup 3}) method was developed for the simultaneous determination of 19 triazine pesticides and their degradation products in processed cereal samples from Chinese total diet study (TDS). The method integrated the addition of isotope internal standards, liquid–liquid extraction (LLE), clean-up with MCX solid-phase extraction (SPE) cartridges and HPLC–LIT-MS{sup 3} analysis with selected reaction monitoring (SRM) mode. Matrix-matched calibration curves showed good linearity (R{sup 2} ≥ 0.9940) verified by applying the Mandel's fitting test (p > 0.087) performed at the 95% confidence level. Decision limits (CCαs) and detection capabilities (CCβs) of the 19 triazine pesticides and their degradation products fell in the ranges of 0.0020–0.4200 μg kg{sup −1} and 0.0024–0.4500 μg kg{sup −1}, respectively. Recoveries ranged from 70.1% to 112.8%, with the relative standard deviations (RSDs) ranging from 1.5% to 13.5%. Furthermore, the proposed method was applied to analyzing the proposed cereal samples from the fourth Chinese TDS. Eleven triazines were detected in six cereal samples with the concentrations ranging from 0.013 to 0.987 μg kg{sup −1}. This method can also be used for the further determination of the triazines in other food group composites, and ultimately served as a methodological foundation for assessing the triazines in the average Chinese diet in the general population.

  9. Active Stabilization of Ion Trap Radiofrequency Potentials

    CERN Document Server

    Johnson, K G; Neyenhuis, B; Mizrahi, J; Monroe, C

    2016-01-01

    We actively stabilize the harmonic oscillation frequency of a laser-cooled atomic ion confined in a rf Paul trap by sampling and rectifying the high voltage rf applied to the trap electrodes. We are able to stabilize the 1 MHz atomic oscillation frequency to better than 10 Hz, or 10 ppm. This represents a suppression of ambient noise on the rf circuit by 34 dB. This technique could impact the sensitivity of ion trap mass spectrometry and the fidelity of quantum operations in ion trap quantum information applications.

  10. Electron beam ion traps and their applications

    Institute of Scientific and Technical Information of China (English)

    ZOU Ya-Ming; Roger HUTTON

    2003-01-01

    A brief introduction to the historical background and current status of electron beam ion traps (EBITs)is presented. The structure and principles of an EBIT for producing highly charged ions are described. Finally,EBITs as a potential tool in hot-plasma diagnostics and in studying frontier problems of highly charged ion physicsare discussed.

  11. Lower-Hybrid Drift Instability Saturation Mechanisms in One-Dimensional Simulations,

    Science.gov (United States)

    1980-09-19

    The linear properties and saturation mechanisms of the lower-hybrid drift instability have been investigated using a one-dimensional particle-hybrid simulation. For low drift velocities (V sub d much less than V sub ti), ion trapping and current relaxation (V sub d approaches limit of 0) are competing processes for stabilization. If the relative electron-ion drift velocity is kept constant in time , ion trapping causes

  12. Identification of Metabolites of 6′-Hydroxy-3,4,5,2′,4′-pentamethoxychalcone in Rats by a Combination of Ultra-High-Performance Liquid Chromatography with Linear Ion Trap-Orbitrap Mass Spectrometry Based on Multiple Data Processing Techniques

    Directory of Open Access Journals (Sweden)

    Siyi Liu

    2016-09-01

    Full Text Available In this study, an efficient strategy was established using ultra-high-performance liquid chromatography coupled with linear ion trap-Orbitrap mass spectrometry (UHPLC-LTQ-Orbitrap MS to profile the in vivo metabolic fate of 6′-hydroxy-3,4,5,2′,4′-pentamethoxychalcone (PTC in rat urine and feces. The UHPLC-LTQ-Orbitrap method combines the high trapping capacity and MSn scanning function of the linear ion trap along with accurate mass measurements within 5 ppm and a resolving power of up to 30,000 over a wider dynamic range compared to many other mass spectrometers. In order to reduce the potential interferences of endogenous substances, the post-acquisition processing method including high-resolution extracted ion chromatogram (HREIC and multiple mass defect filters (MMDF were developed for metabolite detection. As a result, a total of 60 and 35 metabolites were detected in the urine and feces, respectively. The corresponding in vivo reactions such as methylation, hydroxylation, hydrogenation, decarbonylation, demethylation, dehydration, methylation, demethoxylation, sulfate conjugation, glucuronide conjugation, and their composite reactions were all detected in this study. The result on PTC metabolites significantly expanded the understanding of its pharmacological effects, and could be targets for future studies on the important chemical constituents from herbal medicines.

  13. Modular cryostat for ion trapping with surface-electrode ion traps

    CERN Document Server

    Vittorini, Grahame; Brown, Kenneth R; Harter, Alexa W; Doret, S Charles

    2013-01-01

    We present a simple cryostat purpose built for use with surface-electrode ion traps, designed around an affordable, large cooling power commercial pulse tube refrigerator. A modular vacuum enclosure with a single vacuum space facilitates interior access, and enables rapid turnaround and flexiblity for future modifications. Long rectangular windows provide nearly 360 degrees of optical access in the plane of the ion trap, while a circular bottom window near the trap enables NA 0.4 light collection without the need for in-vacuum optics. We evaluate the system's mechanical and thermal characteristics, and we quantify ion trapping performance by trapping 40Ca+, finding small stray electric fields, long ion lifetimes, and low ion heating rates.

  14. Modular cryostat for ion trapping with surface-electrode ion traps

    Science.gov (United States)

    Vittorini, Grahame; Wright, Kenneth; Brown, Kenneth R.; Harter, Alexa W.; Doret, S. Charles

    2013-04-01

    We present a simple cryostat purpose built for use with surface-electrode ion traps, designed around an affordable, large cooling power commercial pulse tube refrigerator. A modular vacuum enclosure with a single vacuum space facilitates interior access and enables rapid turnaround and flexibility for future modifications. Long rectangular windows provide nearly 360° of optical access in the plane of the ion trap, while a circular bottom window near the trap enables NA 0.4 light collection without the need for in-vacuum optics. We evaluate the system's mechanical and thermal characteristics and we quantify ion trapping performance by trapping 40Ca+, finding small stray electric fields, long ion lifetimes, and low ion heating rates.

  15. Electron attachment to anionic clusters in ion traps

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, Franklin, E-mail: franklin.martinez@uni-rostock.de [University of Rostock, Institute of Physics (Germany); Bandelow, Steffi; Marx, Gerrit; Schweikhard, Lutz; Vass, Albert [Ernst-Moritz-Arndt University, Institute of Physics (Germany)

    2015-11-15

    Ion traps are versatile tools for the investigation of gas-phase cluster ions, allowing, e.g., cluster-size selection and extended reaction times. Taking advantage of their particular storage capability of simultaneous trapping of electrons and clusters, Penning traps have been applied for the production of clusters with high negative charge states. Recently, linear radio-frequency quadrupole traps have been demonstrated to be another candidate to produce polyanionic clusters. Operation with rectangular, rather than harmonic, radio-frequency voltages provides field-free time slots for unhindered electron passage through the trap. Several aspects of electron-attachment techniques by means of Penning and radio-frequency traps are addressed and recent experimental results are presented.

  16. Low power RF amplifier circuit for ion trap applications

    Science.gov (United States)

    Noriega, J. R.; García-Delgado, L. A.; Gómez-Fuentes, R.; García-Juárez, A.

    2016-09-01

    A low power RF amplifier circuit for ion trap applications is presented and described. The amplifier is based on a class-D half-bridge amplifier with a voltage mirror driver. The RF amplifier is composed of an RF class-D amplifier, an envelope modulator to ramp up the RF voltage during the ion analysis stage, a detector or amplitude demodulation circuit for sensing the output signal amplitude, and a feedback amplifier that linearizes the steady state output of the amplifier. The RF frequency is set by a crystal oscillator and the series resonant circuit is tuned to the oscillator frequency. The resonant circuit components have been chosen, in this case, to operate at 1 MHz. In testings, the class-D stage operated at a maximum of 78 mW at 1.1356 MHz producing 225 V peak.

  17. Scaling the ion trap quantum processor.

    Science.gov (United States)

    Monroe, C; Kim, J

    2013-03-08

    Trapped atomic ions are standards for quantum information processing, serving as quantum memories, hosts of quantum gates in quantum computers and simulators, and nodes of quantum communication networks. Quantum bits based on trapped ions enjoy a rare combination of attributes: They have exquisite coherence properties, they can be prepared and measured with nearly 100% efficiency, and they are readily entangled with each other through the Coulomb interaction or remote photonic interconnects. The outstanding challenge is the scaling of trapped ions to hundreds or thousands of qubits and beyond, at which scale quantum processors can outperform their classical counterparts in certain applications. We review the latest progress and prospects in that effort, with the promise of advanced architectures and new technologies, such as microfabricated ion traps and integrated photonics.

  18. Ion funnel ion trap and process

    Science.gov (United States)

    Belov, Mikhail E [Richland, WA; Ibrahim, Yehia M [Richland, WA; Clowers, Biran H [West Richland, WA; Prior, David C [Hermiston, OR; Smith, Richard D [Richland, WA

    2011-02-15

    An ion funnel trap is described that includes a inlet portion, a trapping portion, and a outlet portion that couples, in normal operation, with an ion funnel. The ion trap operates efficiently at a pressure of .about.1 Torr and provides for: 1) removal of low mass-to-charge (m/z) ion species, 2) ion accumulation efficiency of up to 80%, 3) charge capacity of .about.10,000,000 elementary charges, 4) ion ejection time of 40 to 200 .mu.s, and 5) optimized variable ion accumulation times. Ion accumulation with low concentration peptide mixtures has shown an increase in analyte signal-to-noise ratios (SNR) of a factor of 30, and a greater than 10-fold improvement in SNR for multiply charged analytes.

  19. Modeling and Optimizing RF Multipole Ion Traps

    Science.gov (United States)

    Fanghaenel, Sven; Asvany, Oskar; Schlemmer, Stephan

    2016-06-01

    Radio frequency (rf) ion traps are very well suited for spectroscopy experiments thanks to the long time storage of the species of interest in a well defined volume. The electrical potential of the ion trap is determined by the geometry of its electrodes and the applied voltages. In order to understand the behavior of trapped ions in realistic multipole traps it is necessary to characterize these trapping potentials. Commercial programs like SIMION or COMSOL, employing the finite difference and/or finite element method, are often used to model the electrical fields of the trap in order to design traps for various purposes, e.g. introducing light from a laser into the trap volume. For a controlled trapping of ions, e.g. for low temperature trapping, the time dependent electrical fields need to be known to high accuracy especially at the minimum of the effective (mechanical) potential. The commercial programs are not optimized for these applications and suffer from a number of limitations. Therefore, in our approach the boundary element method (BEM) has been employed in home-built programs to generate numerical solutions of real trap geometries, e.g. from CAD drawings. In addition the resulting fields are described by appropriate multipole expansions. As a consequence, the quality of a trap can be characterized by a small set of multipole parameters which are used to optimize the trap design. In this presentation a few example calculations will be discussed. In particular the accuracy of the method and the benefits of describing the trapping potentials via multipole expansions will be illustrated. As one important application heating effects of cold ions arising from non-ideal multipole fields can now be understood as a consequence of imperfect field configurations.

  20. Grover search algorithm in an ion trap system

    Institute of Scientific and Technical Information of China (English)

    Zheng Shi-Biao

    2005-01-01

    Two schemes for the implementation of the two-qubit Grover search algorithm in the ion trap system are proposed.These schemes might be experimentally realizable with presently available techniques. The experimental implementation of the schemes would be an important step toward more complex quantum computation in the ion trap system.

  1. Quantum Discrete Fourier Transform in an Ion Trap System

    Institute of Scientific and Technical Information of China (English)

    ZHENG Shi-Biao

    2007-01-01

    We propose two schemes for the implementation of quantum discrete Fourier transform in the ion trap system. In each scheme we design a tunable two-qubit phase gate as the main ingredient. The experimental implementation of the schemes would be an important step toward complex quantum computation in the ion trap system.

  2. A HYBRID METHOD FOR LINEAR PROGRAMMING

    Institute of Scientific and Technical Information of China (English)

    XIU Naihua; WU Fang

    1999-01-01

    In this paper, a hybrid method for linear programming is established.Its search direction is defined as a combination of two directions insimplex method and affine-scaling interior point method.The method is proven to have some promising convergence properties.The relation among the new method, the simplex method and the affine-scalinginteriorpoint method is discussed.

  3. P202-S Expanding the Capabilities of Peptide MRM-Based Assays in Plasma Using a Hybrid Triple-Quadrupole Linear Ion-Trap Mass Spectrometer

    OpenAIRE

    Hunter, C.

    2007-01-01

    As the study of protein biomarkers increases in importance, technical limitations to the detection of low-abundance proteins and high-throughput, high-precision quantitation remain to be overcome. The complexity and dynamic range of the plasma proteome makes the task of specific, quantitative detection even more challenging. Multiple reaction monitoring (MRM) capabilities of triple quadrupole MS systems have been explored as solutions to this challenge due to their well-known sensitivity and ...

  4. Biotransformation and metabolic profile of buddleoside with human intestinal microflora by ultrahigh-performance liquid chromatography coupled to hybrid linear ion trap/orbitrap mass spectrometer.

    Science.gov (United States)

    Tao, Jin-Hua; Duan, Jin-Ao; Jiang, Shu; Qian, Yi-Yun; Qian, Da-Wei

    2016-07-01

    Buddleoside (also known as linarin) as the major flavonoid in Chrysanthemum morifolium Ramat., has been reported to possess a wide range of pharmacological activities. The human intestinal microbiota might have an important impact on drug metabolism and ultimately on the drug oral bioavailability. However, the interaction of the buddleoside with human intestinal bacteria remains unknown. In this study, the conversion of buddleoside by different bacteria from human feces was firstly investigated. A reliable, sensitive and rapid analytical method, ultra performance liquid chromatography was established and successfully applied to investigate the metabolites and metabolic profile of buddleoside by human intestinal bacteria. Among the isolated bacteria, four strains including Escherichia sp. 4, Escherichia sp. 34, Enterococcus sp. 45 and Bacillus sp. 46 showed more powerful conversion capability. Based on the accurate mass data and the characteristic MS(n) product ions, the parent and six metabolites were detected and tentatively identified compared with blank samples. The metabolites were produced by four main metabolic pathways including deglycosylation, acetylation, methylation and hydroxylation. Buddleoside could be firstly converted to its aglycon acacetin (M2) by the majority of the isolated intestinal bacteria. Subsequently, M2 was further metabolize to its methylated (M3), acetylated (M4), hydroxylated (M5) and hydrogenated product (M6). However, acacetin-7-glucosid (M1) was obtained only from the minor bacterial samples like Bacillus sp. 46. To further explain the metabolism of buddleoside, the β-d-glucosidase and α-l-rhamnosidase activities of four strains were analyzed. Bacillus sp. 46 could only produce α-l-rhamnosidase, while the other three strains showed two kinds of enzyme activities. Furthermore, the activities of α-l-rhamnosidase and β-d-glucosidase reached the highest level at 12-18h and 10-12h, respectively. The metabolic routes and metabolites of buddleoside produced by human intestinal microflora were firstly reported in this paper. The results will be very helpful for the further investigation of the pharmacokinetic research of buddleoside and to unravel how it works in vivo.

  5. Characterization of xylazine metabolism in rat liver microsomes using liquid chromatography-hybrid triple quadrupole-linear ion trap-mass spectrometry.

    Science.gov (United States)

    Lavoie, David St-Germain; Pailleux, Floriane; Vachon, Pascal; Beaudry, Francis

    2013-07-01

    Xylazine is an α2 -adrenoceptor agonist and it is widely used in veterinary anesthesia in combination with ketamine. There is limited information on the metabolism of xylazine. A quantitative method for the determination of xylazine by HPLC-ESI/MS/MS was developed. The method consisted of a protein precipitation extraction followed by analysis using liquid chromatography electrospray tandem mass spectrometry. The chromatographic separation was achieved using a Thermo Betasil Phenyl 100 × 2 mm column combined with an isocratic mobile phase composed of acetonitrile, methanol, water and formic acid (60:20:20:0.4) at a flow rate of 300 μL/min. The mass spectrometer was operating in selected reaction monitoring mode and the analytical range was set at 0.05-50 μm. The precision (%CV) and accuracy (%NOM) observed were 2.3-7.2 and 88.2-96.4%. In vitro metabolism studies were performed in rat liver microsomes and results showed moderate cytochrome P450 affinity (Km = 10.1 μm) and a low metabolic stability of xylazine with a half-life of 4.1 min in rat liver microsomes. Five phase 1 metabolites were observed. The main metabolite observed was an oxidation of the thiazine moiety at m/z 235 and, to a lesser extent, we observed the formation of N-(2,6-dimethylphenyl)thiourea at m/z 181 and three distinctive hydroxylated metabolites at m/z 237. Further experiments with ketamine and ketoconazole strongly supported that the metabolism of xylazine to its main metabolite is mediated by CYP3A in rat liver microsomes.

  6. Accurate mass screening and identification of emerging contaminants in environmental samples by liquid chromatography-hybrid linear ion trap Orbitrap mass spectrometry

    NARCIS (Netherlands)

    Hogenboom, A.C.; van Leerdam, J.A.; de Voogt, P.

    2009-01-01

    The European Reach legislation will possibly drive producers to develop newly designed chemicals that will be less persistent, bioaccumulative or toxic. If this innovation leads to an increased use of more hydrophilic chemicals it may result in higher mobilities of chemicals in the aqueous environme

  7. IDENTIFICATION OF MICROCYSTIN TOXINS FROM A STRAIN OF MICROCYSTIS AERUGINOSA BY LIQUID CHROMATOGRAPHY INTRODUCTION INTO A HYBRID LINEAR ION TRAP-FOURIER TRANSFORM ION CYCLOTRON RESONANCE MASS SPECTROMETER

    Science.gov (United States)

    The cyclic heptapeptide microcystin toxins produced by a strain of Microcystis aeruginosa that has not been investigated previously were separated by liquid chromatography and identified by high-accuracy m/z measurements of their [M + H]+ ions and the fragment i...

  8. Accurate mass screening and identification of emerging contaminants in environmental samples by liquid chromatography-hybrid linear ion trap Orbitrap mass spectrometry

    NARCIS (Netherlands)

    Hogenboom, A.C.; van Leerdam, J.A.; de Voogt, P.

    2009-01-01

    The European Reach legislation will possibly drive producers to develop newly designed chemicals that will be less persistent, bioaccumulative or toxic. If this innovation leads to an increased use of more hydrophilic chemicals it may result in higher mobilities of chemicals in the aqueous

  9. Novel radio-frequency ion trap with spherical geometry

    CERN Document Server

    Noshad, Houshyar

    2014-01-01

    Confinement of single ions in a novel radio-frequency (RF) quadrupole ion trap with spherical shape is investigated. An optimization of this spherical ion trap (SIT) is carried out in order to suppress its nonlinearity substantially by eliminating the electric octupole moment. Hence, a trapping potential and consequently an electric field very similar to the ideal quadrupole ion trap (QIT) are obtained. Afterwards, three stability regions for the optimized SIT are numerically computed. The regions coincide well with those reported in the literature for the ideal QIT. The reason is attributed to the zero electric octupole moment of our proposed trap. The SIT simple geometry and relative ease of fabrication along with its increased trapping volume compared to the conventional hyperbolic quadrupole ion trap, make it an appropriate choice for miniaturization.

  10. Modular Universal Scalable Ion-trap Quantum Computer

    Science.gov (United States)

    2016-06-02

    trap quantum computer . This architecture has two separate layers of scalability: the first is to increase the number of ion qubits in a single trap...Distribution Unlimited UU UU UU UU 02-06-2016 1-Aug-2010 31-Jan-2016 Final Report: Modular Universal Scalable Ion-trap Quantum Computer The views...P.O. Box 12211 Research Triangle Park, NC 27709-2211 Ion trap quantum computation , scalable modular architectures REPORT DOCUMENTATION PAGE 11

  11. Laser ablation loading of a radiofrequency ion trap

    CERN Document Server

    Zimmermann, K; Herrera-Sancho, O A; Peik, E

    2012-01-01

    The production of ions via laser ablation for the loading of radiofrequency (RF) ion traps is investigated using a nitrogen laser with a maximum pulse energy of 0.17 mJ and a peak intensity of about 250 MW/cm^2. A time-of-flight mass spectrometer is used to measure the ion yield and the distribution of the charge states. Singly charged ions of elements that are presently considered for the use in optical clocks or quantum logic applications could be produced from metallic samples at a rate of the order of magnitude 10^5 ions per pulse. A linear Paul trap was loaded with Th+ ions produced by laser ablation. An overall ion production and trapping efficiency of 10^-7 to 10^-6 was attained. For ions injected individually, a dependence of the capture probability on the phase of the RF field has been predicted. In the experiment this was not observed, presumably because of collective effects within the ablation plume.

  12. Towards Quantum Simulations Using a Chip Ion Trap

    Science.gov (United States)

    Cao, Chenglin; Wright, Ken; Brennan, Daniel; Ji, Geoffrey; Monroe, Christopher

    2013-05-01

    We report our current experimental progress towards using chip ion traps for quantum simulation. Current progress is being made using a micro-fabricated symmetric trap from GTRI. This trap implements a novel two level design that combines the benefits of both surface traps and linear four-rod traps. The trap has 50 electrodes which allow for the fine control of the DC potential needed to create large anharmonic potentials, to join and split ion chains and to shuttle ions along the trapping axis similar to many surface traps. However this trap also has a much deeper trapping depth than conventional surface traps and improved optical access via an angled slot through the chip wide enough to accommodate higher power laser light which could cause surface charging or damage in a traditional chip trap. These advantages should allow trapping of long ion chains. We hope to use these features as the next step in increasing the size of current quantum simulations being done at Univ of Maryland, which are aimed at exploring quantum phenomena in spin systems in a regime inaccessible to classical simulation. This work is supported by grants from the U.S. Army Research Office with funding from the DARPA OLE program, IARPA, and the MURI program; and the NSF Physics Frontier Center at JQI. We acknowledge the GTRI team of J. Amini, K. Brown, A. Harter, F. Shaikh, R. Slusher, and C. Volin for the fabrication of the trap.

  13. Charge Breeding Techniques in an Electron Beam Ion Trap for High Precision Mass Spectrometry at TITAN

    Science.gov (United States)

    MacDonald, T. D.; Simon, M. C.; Bale, J. C.; Chowdhury, U.; Eibach, M.; Gallant, A. T.; Lennarz, A.; Simon, V. V.; Chaudhuri, A.; Grossheim, A.; Kwiatkowski, A. A.; Schultz, B. E.; Dilling, J.

    2012-10-01

    Penning trap mass spectrometry is the most accurate and precise method available for performing atomic mass measurements. TRIUMF's Ion Trap for Atomic and Nuclear science is currently the only facility to couple its Penning trap to a rare isotope facility and an electron beam ion trap (EBIT). The EBIT is a valuable tool for beam preparation: since the precision scales linearly with the charge state, it takes advantage of the precision gained by using highly charged ions. However, this precision gain is contingent on fast and efficient charge breeding. An optimization algorithm has been developed to identify the optimal conditions for running the EBIT. Taking only the mass number and half-life of the isotope of interest as inputs, the electron beam current density, charge breeding time, charge state, and electron beam energy are all specified to maximize this precision. An overview of the TITAN charge breeding program, and the results of charge breeding simulations will be presented.

  14. General linear dynamics - quantum, classical or hybrid

    CERN Document Server

    Elze, H-T; Vallone, F

    2011-01-01

    We describe our recent proposal of a path integral formulation of classical Hamiltonian dynamics. Which leads us here to a new attempt at hybrid dynamics, which concerns the direct coupling of classical and quantum mechanical degrees of freedom. This is of practical as well as of foundational interest and no fully satisfactory solution of this problem has been established to date. Related aspects will be observed in a general linear ensemble theory, which comprises classical and quantum dynamics in the form of Liouville and von Neumann equations, respectively, as special cases. Considering the simplest object characterized by a two-dimensional state-space, we illustrate how quantum mechanics is special in several respects among possible linear generalizations.

  15. CULA: hybrid GPU accelerated linear algebra routines

    Science.gov (United States)

    Humphrey, John R.; Price, Daniel K.; Spagnoli, Kyle E.; Paolini, Aaron L.; Kelmelis, Eric J.

    2010-04-01

    The modern graphics processing unit (GPU) found in many standard personal computers is a highly parallel math processor capable of nearly 1 TFLOPS peak throughput at a cost similar to a high-end CPU and an excellent FLOPS/watt ratio. High-level linear algebra operations are computationally intense, often requiring O(N3) operations and would seem a natural fit for the processing power of the GPU. Our work is on CULA, a GPU accelerated implementation of linear algebra routines. We present results from factorizations such as LU decomposition, singular value decomposition and QR decomposition along with applications like system solution and least squares. The GPU execution model featured by NVIDIA GPUs based on CUDA demands very strong parallelism, requiring between hundreds and thousands of simultaneous operations to achieve high performance. Some constructs from linear algebra map extremely well to the GPU and others map poorly. CPUs, on the other hand, do well at smaller order parallelism and perform acceptably during low-parallelism code segments. Our work addresses this via hybrid a processing model, in which the CPU and GPU work simultaneously to produce results. In many cases, this is accomplished by allowing each platform to do the work it performs most naturally.

  16. Development and Characterization of a 171Yb+ Miniature Ion Trap Frequency Standard

    CERN Document Server

    Partner, Heather L

    2012-01-01

    This dissertation reports on the development of a low-power, high-stability miniature atomic frequency standard based on 171Yb+ ions. The ions are buffer-gas cooled and held in a linear quadrupole trap that is integrated into a sealed, getter-pumped vacuum package, and interrogated on the 12.6 GHz hyperfine transition. We hope to achieve a long-term fractional frequency stability of 10^-14 with a miniature clock that consumes only 50 mW of power and occupies a volume of 5 cm^3. I discuss our progress over several years of work on this project. We began by building a conventional tabletop clock to use as a test bed while developing several designs of miniature ion-trap vacuum packages, while also developing techniques for various aspects of the clock operation, including ion loading, laser and magnetic field stabilization, and a low power ion trap drive. The ion traps were modeled using boundary element software to assist with the design and parameter optimization of new trap geometries. We expect a novel trap...

  17. Extending the dynamic range of the ion trap by differential mobility filtration.

    Science.gov (United States)

    Hall, Adam B; Coy, Stephen L; Kafle, Amol; Glick, James; Nazarov, Erkinjon; Vouros, Paul

    2013-09-01

    A miniature, planar, differential ion mobility spectrometer (DMS) was interfaced to an LCQ classic ion trap to conduct selective ion filtration prior to mass analysis in order to extend the dynamic range of the trap. Space charge effects are known to limit the functional ion storage capacity of ion trap mass analyzers and this, in turn, can affect the quality of the mass spectral data generated. This problem is further exacerbated in the analysis of mixtures where the indiscriminate introduction of matrix ions results in premature trap saturation with non-targeted species, thereby reducing the number of parent ions that may be used to conduct MS/MS experiments for quantitation or other diagnostic studies. We show that conducting differential mobility-based separations prior to mass analysis allows the isolation of targeted analytes from electrosprayed mixtures preventing the indiscriminate introduction of matrix ions and premature trap saturation with analytically unrelated species. Coupling these two analytical techniques is shown to enhance the detection of a targeted drug metabolite from a biological matrix. In its capacity as a selective ion filter, the DMS can improve the analytical performance of analyzers such as quadrupole (3D or linear) and ion cyclotron resonance (FT-ICR) ion traps that depend on ion accumulation.

  18. Extending the Dynamic Range of the Ion Trap by Differential Mobility Filtration

    Science.gov (United States)

    Hall, Adam B.; Coy, Stephen L.; Kafle, Amol; Glick, James; Nazarov, Erkinjon

    2013-01-01

    A miniature, planar, differential ion mobility spectrometer (DMS) was interfaced to an LCQ classic ion trap to conduct selective ion filtration prior to mass analysis in order to extend the dynamic range of the trap. Space charge effects are known to limit the functional ion storage capacity of ion trap mass analyzers and this, in turn, can affect the quality of the mass spectral data generated. This problem is further exacerbated in the analysis of mixtures where the indiscriminate introduction of matrix ions results in premature trap saturation with non-targeted species, thereby reducing the number of parent ions that may be used to conduct MS/MS experiments for quantitation or other diagnostic studies. We show that conducting differential mobility-based separations prior to mass analysis allows the isolation of targeted analytes from electrosprayed mixtures preventing the indiscriminate introduction of matrix ions and premature trap saturation with analytically unrelated species. Coupling these two analytical techniques is shown to enhance the detection of a targeted drug metabolite from a biological matrix. In its capacity as a selective ion filter, the DMS can improve the analytical performance of analyzers such as quadrupole (3-D or linear) and ion cyclotron resonance (FT-ICR) ion traps that depend on ion accumulation. PMID:23797861

  19. Surface ion trap structures with excellent optical access for quantum information processing

    Science.gov (United States)

    Maunz, P.; Blain, M.; Benito, F.; Chou, C.; Clark, C.; Descour, M.; Ellis, R.; Haltli, R.; Heller, E.; Kemme, S.; Sterk, J.; Tabakov, B.; Tigges, C.; Stick, D.

    2013-05-01

    Microfabricated surface electrode ion traps are necessary for the advancement of trapped ion quantum information processing as it offers a scalable way for realizing complex trap structures capable of storing and controlling many ions. The most promising way of performing two-qubit quantum gates in a chain of trapped ions is to focus laser beams on individual ions of the chain to drive gates. However, in surface ion traps the close proximity of the ions to the surface and the size of the chips usually cannot accommodate the tightly focused laser beams necessary to address individual ions parallel to the chip surface. Here we present a surface electrode ion trap monolithically fabricated in standard silicon technology that implements a linear quadrupole trap on a bowtie shaped chip with a narrow section that is only 1.2 mm wide. Laser beams parallel to the surface can be focused down to a waist of 4 μm with enough separation from the trap chip to prevent light scattering. The trap structure incorporates two Y-junctions for reordering ions and is optimized for quantum information processing. This work was supported by the Intelligence Advanced Research Projects Activity (IARPA). Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the US Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  20. Ion-Trapping Effect in UVSOR Storage Ring

    Science.gov (United States)

    Kasuga, Toshio; Yonehara, Hiroto; Kinoshita, Toshio; Hasumoto, Masami

    1985-09-01

    UVSOR is an electron-stage ring dedicated to vacuum ultraviolet synchrotron radiation research. The first beam was stored in the ring in November 1983, and from that time on, efforts have been devoted to improving the performance of the ring. Some inconvenient phenomena have been found during the accelerator studies. One of the most serious problems is the growth of the vertical size of the electron beam. This phenomenon is explained by the ion-trapping effect, in which the ions trapped in the electron beam change the operating point of the storage ring and enhance the coupling between horizontal and vertical oscillations, resulting in a considerable increase in the vertical beam size. This ion trapping was successfully cured by the RF knockout method, which excited the betatron oscillation.

  1. Ion traps in nuclear physics-Recent results and achievements

    Science.gov (United States)

    Eronen, Tommi; Kankainen, Anu; Äystö, Juha

    2016-11-01

    Ion traps offer a way to determine nuclear binding energies through atomic mass measurements with a high accuracy and they are routinely used to provide isotopically or even isomerically pure beams of short-living ions for post-trap decay spectroscopy experiments. In this review, different ion-trapping techniques and progresses in recent nuclear physics experiments employing low-energy ion traps are discussed. The main focus in this review is on the benefit of recent high accuracy mass measurements to solve some key problems in physics related to nuclear structure, nuclear astrophysics as well as neutrinos. Also, several cases of decay spectroscopy experiments utilizing trap-purified ion samples are summarized.

  2. Atomic and nuclear physics with stored particles in ion traps

    CERN Document Server

    Kluge, H J; Herfurth, F; Quint, W

    2002-01-01

    Trapping and cooling techniques play an increasingly important role in many areas of science. This review concentrates on recent applications of ion traps installed at accelerator facilities to atomic and nuclear physics such as mass spectrometry of radioactive isotopes, weak interaction studies, symmetry tests, determination of fundamental constants, laser spectroscopy, and spectroscopy of highly-charged ions. In addition, ion traps are proven to be extremely efficient devices for (radioactive) ion beam manipulation as, for example, retardation, accumulation, cooling, beam cleaning, charge-breeding, and bunching.

  3. Characterization and simultaneous quantification of biological aporphine alkaloids in Litsea cubeba by HPLC with hybrid ion trap time-of-flight mass spectrometry and HPLC with diode array detection.

    Science.gov (United States)

    Zhang, Shuiying; Zhang, Qian; Guo, Qiang; Zhao, Yunfang; Gao, Xiaoli; Chai, Xingyun; Tu, Pengfei

    2015-08-01

    The root and rhizome of Litsea cubeba (Lour) Pers., named 'Dou-chi-jiang' in Chinese, has been traditionally used for treatment of cardiovascular and cerebrovascular diseases, rheumatic arthralgia, and other diseases in China. Aporphine alkaloids are its characteristic ingredients and responsible for its bioactivities, especially anti-inflammatory and analgesic effects. A sensitive and reliable high-performance liquid chromatography with diode array detection-tandem mass spectrometry method was developed for characterization and simultaneous determination of biological aporphine alkaloids in 'Dou-chi-jiang'. The optimized chromatographic conditions were performed on an Eclipse XDB C18 column with a gradient of acetonitrile/water containing 0.1% formic acid as the mass spectrometry mobile phase and acetonitrile/water containing 0.2% diethylamine (pH 3.10, adjusted by acetic acid) as the liquid chromatography mobile phase. The fragmentation pathways by loss of CO, ·CH3 , ·NH3 , and ·NH2 CH3 were detected as characteristic for aporphine alkaloids. Based on these characteristics, total 12 analogues were identified. The quantification method was validated in terms of linearity, precision, and accuracy for six major aporphine alkaloids, which was successfully applied for simultaneous determination in ten batches of samples. The established method is simple, rapid, and specific for characterization and quantitation of aporphine alkaloids in 'Dou-chi-jiang' and other traditional Chinese medicines rich in this kind of ingredient.

  4. An introduction to the trapping of clusters with ion traps and electrostatic storage devices

    Energy Technology Data Exchange (ETDEWEB)

    Bredy, R; Bernard, J; Chen, L; Montagne, G; Li, B; Martin, S [Universite de Lyon, F-69622, Lyon (France); Universite Lyon 1, Villeurbanne (France); CNRS, UMR 5579, LASIM (France)

    2009-08-14

    This paper presents an introduction to the application of ion traps and storage devices for cluster physics. Some experiments involving cluster ions in trapping devices such as Penning traps, Paul traps, quadrupole or multipole linear traps are briefly discussed. Electrostatic ion storage rings and traps which allow for the storage of fast ion beams without mass limitation are presented as well. We also report on the recently developed mini-ring, a compact electrostatic ion storage ring for cluster, molecular and biomolecular ion studies. (review)

  5. Comparison of quadrupole and ion trap mass spectrometry for the analysis of polychlorinated biphenyls

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, E.; DeVita, W. [Univ. of Wisconsin, Stevens Point, WI (United States)

    1995-12-31

    Polychlorinated biphenyls (PCBs) are often analyzed using gas chromatography with an electron capture detector (GC/ECD) because of the sensitivity of this detection technique toward this class of compounds. However, use of gas chromatography/mass spectrometry (GC/MS) can provide additional selectivity, thus minimizing the likelihood of false positive results from interfering compounds. GC/MS provides a higher degree of confidence in the identification of the chromatographic peaks, but is often limited, in comparison to GC/ECL, by its sensitivity. The two most common mass analyzers used are quadrupole and ion trap detectors. In this study the authors propose to document the capabilities of both quadrupole and ion trap analyzer for analysis of PCBs. They will compare and contrast the sensitivities and linear ranges for these compounds. Sensitivities will be assessed by signal-to-noise ratio comparisons. Linearity of the calibrated range will also be investigated through evaluation of the relative response factors versus concentration of PCB for a fixed concentration of internal standard. Estimations will be made of the appropriate linear ranges on the two instruments and comparisons made in both the full scan and selected ion modes.

  6. Determination of carbendazim and thiophanate-methyl in red wine by high pressure liquid chromatography-linear ion trap mass spectrometry%高压液相色谱-线性离子阱串联质谱法测定红葡萄酒中多菌灵和甲基硫菌灵

    Institute of Scientific and Technical Information of China (English)

    李鹏; 刘凯丽; 杨欣; 赵云峰; 吴永宁

    2013-01-01

      目的建立红葡萄酒中多菌灵和甲基硫菌灵残留的高压液相色谱-串联线性离子阱质谱(HPLC-LIT-MS/MS)检测方法.方法样品经过乙腈提取,在梯度洗脱程序下经CAPCELL PAK CR 1:20色谱柱分离后,采用HPLC-LIT-MS/MS,在二级质谱选择反应监测(SRM)模式进行测定.结果红葡萄酒中多菌灵和甲基硫菌灵添加水平为10、20、50μg/L时,平均回收率分别为82.5%~103.1%和93.7%~115.2%.检出限(LODs)分别为0.063μg/L和0.019μg/L,定量限(LOQs)分别为0.125μg/L和0.075μg/L.结论该方法快速简便,灵敏度高,准确度和精密度均满足痕量分析要求.%Objective To develop a method of high pressure liquid chromatography-linear ion trap mass spectrometry (HPLC-LIT-MS) for the determination of carbendazim and thiophanate-methyl in red wine. Methods Samples were ultrasonically extracted with acetonitrile, separated on a CAPCELL PAK CR 1:20 column with gradient elution and the mass spectrometric acquisition was carried out under the mode of selected reaction monitoring (SRM). Results The average recoveries of carbendazim and thiophanate-methyl in red wine at 10, 20μg/L and 50μg/L were 82.5%~103.1%and 93.7%~115.2%, respectively. The limits of detection (LODs) were 0.063 μg/L and 0.019μg/L, and the limits of quantification (LOQs) were 0.125μg/L and 0.075μg/L. Conclusion The established method is fast, simple, selective, precise and accurate, and it is suitable for quantitative and qualitative detection of carbendazim and thiophanate-methyl in red wine.

  7. Ion trapping in the high-energy storage ring HESR

    Energy Technology Data Exchange (ETDEWEB)

    Hinterberger, Frank [Bonn Univ. (Germany). Helmholtz-Institut fuer Strahlen- und Kernphysik

    2011-10-15

    The problem of ion trapping in the high-energy storage ring HESR is studied in the present report. Positive ions are trapped in the negative potential well of the antiproton beam. The ions are produced by the interaction between the antiproton beam and the residual gas. The adverse effects of ion trapping like tune shifts, tune spreads and coherent instabilities are reviewed. The ion production rate by ionization of the residual gas molecules is estimated. The negative potential well and the corresponding electric fields of the antiproton beam are evaluated in order to study the transverse and longitudinal motion of the ions and the accumulation in trapping pockets. The removal of ions can be achieved using clearing electrodes and under certain conditions resonant transverse beam shaking. Diagnostic tools and measurements of trapped ion effects are sketched. (orig.)

  8. Confining rigid balls by mimicking quadrupole ion trapping

    CERN Document Server

    Fan, Wenkai; Wang, Sihui; Zhou, Huijun

    2016-01-01

    The rotating saddle not only is an interesting system that is able to trap a ball near its saddle point, but can also intuitively illustrate the operating principles of quadrupole ion traps in modern physics. Unlike the conventional models based on the mass-point approximation, we study the stability of a ball in a rotating-saddle trap using rigid-body dynamics. The stabilization condition of the system is theoretically derived and subsequently verified by experiments. The results are compared with the previous mass-point model, giving large discrepancy as the curvature of the ball is comparable to that of the saddle. We also point out that the spin angular velocity of the ball is analogous to the cyclotron frequency of ions in an external magnetic field utilized in many prevailing ion-trapping schemes.

  9. Comparative numerical studies of ion traps with integrated optical cavities

    CERN Document Server

    Podoliak, Nina; Keller, Matthias; Horak, Peter

    2016-01-01

    We study a range of radio-frequency ion trap geometries and investigate the effect of integrating dielectric cavity mirrors on their trapping potential. We aim to identify ion trap and cavity configurations that are best suited for achieving small cavity volumes and thus large ion-photon coupling as required for scalable quantum information networks. In particular, we investigate the trapping potential distortions caused by the dielectric material of the cavity mirrors for different mirror orientations with respect to the trapping electrodes, as well as for mirror misalignment. We also analyze the effect of the mirror material properties such as dielectric constants and surface conductivity, and study the effect of surface charges on the mirrors. The smallest trapping potential distortions are found if the cavities are aligned along the major symmetry axis of the electrode geometries. These cavity configurations also appear to be the most stable with respect to any mirror misalignment.

  10. In-Vacuum Electronics for Microfabricated Ion Traps

    CERN Document Server

    Guise, Nicholas D; Hayden, Harley; Pai, C-S; Volin, Curtis; Brown, K R; Merrill, J True; Harter, Alexa W; Amini, Jason M; Lust, Lisa M; Muldoon, Kelly; Carlson, Doug; Budach, Jerry

    2014-01-01

    The advent of microfabricated ion traps for the quantum information community has allowed research groups to build traps that incorporate an unprecedented number of trapping zones. However, as device complexity has grown, the number of digital-to-analog converter (DAC) channels needed to control these devices has grown as well, with some of the largest trap assemblies now requiring nearly one hundred DAC channels. Providing electrical connections for these channels into a vacuum chamber can be bulky and difficult to scale beyond the current numbers of trap electrodes. This paper reports on the development and testing of an in-vacuum DAC system that uses only 9 vacuum feedthrough connections to control a 78-electrode microfabricated ion trap. The system is characterized by trapping single and multiple $^{40}$Ca$^+$ ions. The measured axial mode stability, ion heating rates, and transport fidelities for a trapped ion are comparable to systems with external(air-side) National Instruments PXI-6733 DACs.

  11. Single Ion Trapping for the Enriched Xenon Observatory

    Energy Technology Data Exchange (ETDEWEB)

    Waldman, Samuel J.; /Stanford U., Phys. Dept. /SLAC

    2006-03-28

    In the last decade, a variety of neutrino oscillation experiments have established that there is a mass difference between neutrino flavors, without determining the absolute neutrino mass scale. The Enriched Xenon Observatory for neutrinoless double beta decay (EXO) will search for the rare decays of xenon to determine the absolute value of the neutrino mass. The experiment uses a novel technique to minimize backgrounds, identifying the decay daughter product in real time using single ion spectroscopy. Here, we describe single ion trapping and spectroscopy compatible with the EXO detector. We extend the technique of single ion trapping in ultrahigh vacuum to trapping in xenon gas. With this technique, EXO will achieve a neutrino mass sensitivity of {approx_equal} .010 eV.

  12. Ion trap with integrated time-of-flight mass spectrometer

    CERN Document Server

    Schneider, Christian; Yu, Peter; Hudson, Eric R

    2015-01-01

    Recently, we reported an ion trap experiment with an integrated time-of-flight mass spectrometer (TOFMS) [Phys. Rev. Appl. 2, 034013 (2014)] focussing on the improvement of mass resolution and detection limit due to sample preparation at millikelvin temperatures. The system utilizes a radio-frequency (RF) ion trap with asymmetric drive for storing and manipulating laser-cooled ions and features radial extraction into a compact $275$ mm long TOF drift tube. The mass resolution exceeds $m / \\Delta m = 500$, which provides isotopic resolution over the whole mass range of interest in current experiments and constitutes an improvement of almost an order of magnitude over other implementations. In this manuscript, we discuss the experimental implementation in detail, which is comprised of newly developed drive electronics for generating the required voltages to operate RF trap and TOFMS, as well as control electronics for regulating RF outputs and synchronizing the TOFMS extraction.

  13. Towards the understanding of Decoherence on Ion Traps

    CERN Document Server

    Terra-Cunha, M O

    2004-01-01

    Two mechanisms of decoherence in ion traps are studied, specially related to the experiment [Kielpinski et al., Science 291 (2001) 1013]. Statistical hypothesis are made about the unknown variables and the expected behaviour of the visibility of the best experimental pattern is calculated for each mechanism. Data from the experiment are analyzed and show to be insufficient to distinguish between them. We suggest improvements which can do this with slight modifications in the present facilities.

  14. Quantum entanglement in a two-dimensional ion trap

    Institute of Scientific and Technical Information of China (English)

    王成志; 方卯发

    2003-01-01

    In this paper, we investigate the quantum entanglement in a two-dimensional ion trap system. We discuss the quantum entanglement between the ion and phonons by using reduced entropy, and that between two degrees of freedom of the vibrational motion along x and y directions by using quantum relative entropy. We discuss also the influence of initial state of the system on the quantum entanglement and the relation between two entanglements in the trapped ion system.

  15. Quantum entanglement in a two—dimensional ion trap

    Institute of Scientific and Technical Information of China (English)

    王成志; 方卯发

    2003-01-01

    In this paper,we investigate the quantum entanglement in a two-dimensional ion trap system.we discuss the quantum entanglement between the ion and phonons by using reduced entropy,and that between two degrees of freedom of the vibrational motion along x and y directions by using quantum relative entropy.We discuss also the influence of initial state of the system on the quantum entanglement and the relation between two entanglements in the trapped ion system.

  16. Software development for a fluid portable ion trap mass spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Hart, K.J.; Buchanan, M.V.; Wise, M.B. [Oak Ridge National Lab., TN (United States)

    1994-12-31

    Most mass spectrometer data systems are developed and optimized for the benchtop GC/MS market and thus do not adequately address the requirements for direct sampling methods. Field analysis also places greater demands on real-time data processing including automated interpretation and quantification for target analytes. The current field portable ion trap mass spectrometers developed at ORNL are based on the Finnigan Magnum ion trap mass spectrometer which provides a procedure language for user programs. A series of these procedures has been developed to support direct sampling ion trap mass spectrometry studies and is part of an overall software development strategy to address the needs of these direct sampling instruments for rapid field analysis and process monitoring. The general approach has been to create task oriented menus that lead a user through a complete analysis. Thus, the user is focused on completing tasks rather than learning and using all of the software components to complete the task. Additionally, user input has been minimized to save keyboard input and data logging time.

  17. Profiling of lipid species by normal-phase liquid chromatography, nanoelectrospray ionization, and ion trap-orbitrap mass spectrometry

    DEFF Research Database (Denmark)

    Sokol, Elena; Almeida, Reinaldo; Hannibal-Bach, Hans Kristian

    2013-01-01

    chromatography-Fourier transform mass spectrometry (LC-FTMS) and LC-ITMS(2) (ion trap tandem mass spectrometry) for profiling and structural analysis of lipid species. The workflow uses a normal-phase LC system for efficient separation of apolar and polar lipid species combined with sensitive and specific...... analysis powered by a chip-based nanoelectrospray ion source and a hybrid ion trap-orbitrap mass spectrometer. The workflow was executed using a primary LC-FTMS survey routine for identification and profiling of lipid species based on high-mass accuracy and retention time followed by a targeted LC-ITMS(2......Detailed analysis of lipid species can be challenging due to their structural diversity and wide concentration range in cells, tissues, and biofluids. To address these analytical challenges, we devised a reproducible, sensitive, and integrated lipidomics workflow based on normal-phase liquid...

  18. 液相色谱-线性离子阱串联质谱法检测人正常晶状体水溶性蛋白质%Normal water-soluble proteins detection of human lens by liquid chromatography-linear ion trap tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    姚志斌; 宁远; 赵宇; 张劲松

    2011-01-01

    Objective To detect and analyze the compositions and functions of water-soluble proteins of normal human lens. Methods The water-soluble proteins of normal human lens samples were separated by polyacrylamide gels and liquid chroma toyaphy. Linear ion trap tandem mass spectrometry was used for proteins identifica tion. The function analyses of identified proteins were based on over-represented and under-represented annotations of gene ontology( GO). Results Two hundreds and forty-two water-soluble proteins of normal human lens were identified ,including various enzymes and other important functional proteins. Overrepresented annotations of cellu Iar component of identified lens proteins included structural constituent of eye lens,cy toplasm, intracellular, intraceUular part, cytoskeleton; Overrepresented annotations of molecular function included catalytic activity, structural molecule activity, oxidoreduc tase activity, isomerase activity; Overrepresented annotations of biologcal process in cluded glycolysis, pentose-phosphate shunt, cellular macromolecule catabolic process, NADP metabolic process , nicotinamide metabolic process , pyridine nucleotide metabolic process , NADPH regeneration , regulation of ceUular component organization and biogen esis , microtubule-based process. Analytic result of GO showed the functions of identified proteins were closely related to physical activity of normal lens, and further confirmed the reliability of proteins identification. Conclusions The linear ion trap tandem mass spectrometry has unique advantages in water-soluble proteins identification of nor mal human lens. Bioinformatic tools such as GO-based functional analyses are beneficial for proteomics studies.%目的 检测和分析人正常晶状体水溶性蛋白质的组成和功能.方法 通过聚丙烯酰胺凝胶和液相色谱分离晶状体中的水溶性蛋白质,应用线性离子阱串联质谱仪鉴定蛋白质.运用基因本体论(gene ontology,GO)对鉴定

  19. ON THE STABILIZATION OF THE LINEAR HYBRID SYSTEM STRUCTURE

    Directory of Open Access Journals (Sweden)

    Kirillov

    2014-11-01

    Full Text Available The linear control hybrid system, consisting of a fi- nite set of subsystems (modes having different dimensions, is considered. The moments of reset time are determined by some complementary function – evolutionary time. This function satisfies the special complementary ordinary differential equation. The mode stabilization problem is solved for some class of piecewise linear controls. The method of stabilization relies on the set of invariant planes, the existence of which is due to the special form of the hybrid system.

  20. Simultaneous identification and detection of 16 anabolic steroid hormones in muscle using liquid chromatography coupled to quadrupole/linear ion trap mass spectrometry%液相色谱-四极杆/离子阱质谱同时确证和测定肌肉中16种同化甾体激素残留

    Institute of Scientific and Technical Information of China (English)

    张鸿伟; 蔡雪; 林黎明; 陈亮珍; 梁成珠; 鲍蕾; 汤志旭; 牛增元; 王凤美

    2012-01-01

    采用液相色谱-四极杆/离子阱质谱(LC-Q/Trap-MS)建立了肌肉中16种同化甾体激素类物质(ASs)残留的同时确证及测定方法.肌肉中的ASs采用乙腈超声辅助提取,正己烷脱脂,氨基固相萃取柱净化,CAPCELL PAKC18 MGⅢ柱(150 mm×2.0 mm,5.0μm)分离,0.1% (v/v)甲酸-乙腈溶液和0.1% (v/v)甲酸-5 mmol/L甲酸铵水溶液为流动相梯度洗脱;预设定多反应监测( sMRM)-信息依赖性采集(IDA)-增强子离子扫描(EPI)模式检测,在线EPI谱库确证,内标法定量.结果表明,16种ASs在线性范围内线性关系良好(r≥0.999);定量限(LOQ,S/N≥10)为0.029~ 0.36 μg/kg;3个添加水平(0.5、2.0和20 μg/kg)下的回收率为89.9% ~ 118%;相对标准偏差(RSD)为6.3%~16.2%.该方法准确灵敏,一次性完成16种ASs的确证和测定,可有效用于肌肉组织中ASs残留的监测分析.%A comprehensive method for simultaneous identification and detection of 16 anabolic steroid hormones (ASs, including andorgens, gestagens and their esters) in muscle samples was developed with liquid chromatography coupled to quadrupole/linear ion trap mass spectrometry (LC-Q/Trap-MS). The ASs in muscle samples were extracted with acetonitrile under ultrasonic assistance. The extract was defatted by n-hexane with liquid-liquid partitioning and followed by clean-up with NH2 solid phase extraction (SPE) cartridge. The separation of ana-lytes was carried out on a CAPCELL PAK C18 MG Ⅲ column (150 mm ×2.0 mm, 5. 0 μm) using mobile phases of 0.1 % ( v/v) formic acid in acetonitrile and 0.1% ( v/v) formic acid-5 mmol/L ammonium formate aqueous solution with gradient elution. A scheduled multiple reaction monitoring (sMRM) in positive mode as survey scan and an enhanced product ion (EPI) scan as dependent scan in an information-dependent acquisition (IDA) experiment was adopted in mass spectrometry acquisition. On-line lab-built MS/MS library and internal standards were employed for the

  1. Ra{sup +} ion trapping - atomic parity violation measurement and an optical clock

    Energy Technology Data Exchange (ETDEWEB)

    Mohanty, Amita; Dijck, Elwin A.; Nunez Portela, Mayerlin; Valappol, Nivedya; Boell, Oliver; Jungmann, Klaus; Onderwater, Cornelis G. G.; Schlesser, Sophie; Timmermans, Rob G.E.; Willmann, Lorenz; Wilschut, Hans W. [University of Groningen, FWN, Groningen (Netherlands)

    2014-07-01

    A single trapped Ra{sup +} ion has an excellent potential for a precision measurement of the Weinberg mixing angle at low momentum transfer and testing thereby the electroweak running. The absolute frequencies of the transition 7s {sup 2}S{sub 1/2}-7d{sup 2}D{sub 3/2} at wavelength 828 nm have been determined in {sup 212*214}Ra{sup +} to better than 19 MHz with laser spectroscopy on small samples of ions trapped in a linear Paul trap at the online facility TRIμP of KVI. The measurement of the Weinberg angle requires the localization of the ion within a fraction of an optical wavelength. The current experiments are focused on trapping and laser spectroscopy on a single Ba{sup +} as a precursor for Ra{sup +}. Work towards single ion trapping of Ra{sup +}, including the preparation of an offline {sup 223}Ra source is in progress. Most elements of the setup for single Ra+ ion parity measurement are also well suited for realizing a most stable optical clock.

  2. Minimally complex ion traps as modules for quantum communication and computing

    Science.gov (United States)

    Nigmatullin, Ramil; Ballance, Christopher J.; de Beaudrap, Niel; Benjamin, Simon C.

    2016-10-01

    Optically linked ion traps are promising as components of network-based quantum technologies, including communication systems and modular computers. Experimental results achieved to date indicate that the fidelity of operations within each ion trap module will be far higher than the fidelity of operations involving the links; fortunately internal storage and processing can effectively upgrade the links through the process of purification. Here we perform the most detailed analysis to date on this purification task, using a protocol which is balanced to maximise fidelity while minimising the device complexity and the time cost of the process. Moreover we ‘compile down’ the quantum circuit to device-level operations including cooling and shuttling events. We find that a linear trap with only five ions (two of one species, three of another) can support our protocol while incorporating desirable features such as global control, i.e. laser control pulses need only target an entire zone rather than differentiating one ion from its neighbour. To evaluate the capabilities of such a module we consider its use both as a universal communications node for quantum key distribution, and as the basic repeating unit of a quantum computer. For the latter case we evaluate the threshold for fault tolerant quantum computing using the surface code, finding acceptable fidelities for the ‘raw’ entangling link as low as 83% (or under 75% if an additional ion is available).

  3. Optimization of parameters of a surface-electrode ion trap and experimental study of influences of surface on ion lifetime

    Science.gov (United States)

    Ou, BaoQuan; Zhang, Jie; Zhang, XinFang; Xie, Yi; Chen, Ting; Wu, ChunWang; Wu, Wei; Chen, PingXing

    2016-12-01

    In this paper we report the optimal design and fabrication of a gold-on-silica linear segmented surface-electrode ion trap. By optimizing the thickness and width of the electrodes, we improved the trapping ability and trap scalability. By using some practical experimental operation methods, we successfully minimized the trap heating rate. Consequently, we could trap a string of up to 38 ions, and a zigzag structure with 24 ions, and transport two trapped ions to different zones. We also studied the influences of the ion chip surface on the ion lifetime. The excellent trapping ability and flexibility of operation of the planar ion trap shows that it has high feasibility for application in the development a practical quantum information processor or quantum simulator.

  4. Electron beam ion source and electron beam ion trap (invited).

    Science.gov (United States)

    Becker, Reinard; Kester, Oliver

    2010-02-01

    The electron beam ion source (EBIS) and its trap variant [electron beam ion trap (EBIT)] celebrated their 40th and 20th anniversary, respectively, at the EBIS/T Symposium 2007 in Heidelberg. These technologically challenging sources of highly charged ions have seen a broad development in many countries over the last decades. In contrast to most other ion sources the recipe of improvement was not "sorcery" but a clear understanding of the physical laws and obeying the technological constraints. This review will report important achievements of the past as well as promising developments in the future.

  5. Electron beam ion source and electron beam ion trap (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Reinard [Scientific Software Service, Kapellenweg 2a, D-63571 Gelnhausen (Germany); Kester, Oliver [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, Michigan 48824 (United States)

    2010-02-15

    The electron beam ion source (EBIS) and its trap variant [electron beam ion trap (EBIT)] celebrated their 40th and 20th anniversary, respectively, at the EBIS/T Symposium 2007 in Heidelberg. These technologically challenging sources of highly charged ions have seen a broad development in many countries over the last decades. In contrast to most other ion sources the recipe of improvement was not ''sorcery'' but a clear understanding of the physical laws and obeying the technological constraints. This review will report important achievements of the past as well as promising developments in the future.

  6. Experimental demonstration of a surface-electrode multipole ion trap

    CERN Document Server

    Maurice, Mark; Green, Dylan; Farr, Andrew; Burke, Timothy; Hilleke, Russell; Clark, Robert

    2015-01-01

    We report on the design and experimental characterization of a surface-electrode multipole ion trap. Individual microscopic sugar particles are confined in the trap. The trajectories of driven particle motion are compared with a theoretical model, both to verify qualitative predictions of the model, and to measure the charge-to-mass ratio of the confined particle. The generation of harmonics of the driving frequency is observed as a key signature of the nonlinear nature of the trap. We remark on possible applications of our traps, including to mass spectrometry.

  7. Ion-trap quantum logic using long-wavelength radiation.

    Science.gov (United States)

    Mintert, F; Wunderlich, C

    2001-12-17

    A quantum information processor is proposed that combines experimental techniques and technology successfully demonstrated either in nuclear magnetic resonance experiments or with trapped ions. An additional inhomogeneous magnetic field applied to an ion trap (i) shifts individual ionic resonances (qubits), making them distinguishable by frequency, and (ii) mediates the coupling between internal and external degrees of freedom of trapped ions. This scheme permits one to individually address and coherently manipulate ions confined in an electrodynamic trap using radiation in the radiofrequency or microwave regime.

  8. Charting molecular composition of phosphatidylcholines by fatty acid scanning and ion trap MS3 fragmentation

    DEFF Research Database (Denmark)

    Ekroos, Kim; Ejsing, Christer S.; Bahr, Ute

    2003-01-01

    The molecular composition of phosphatidylcholines (PCs) in total lipid extracts was characterized by a combination of multiple precursor ion scanning on a hybrid quadrupole time-of-flight mass spectrometer and MS3 fragmentation on an ion trap mass spectrometer. Precursor ion spectra for 50 acyl...... spectrometer quantified the relative amount of their positional isomers, thus providing the most detailed and comprehensive characterization of the molecular composition of the pool of PCs at the low-picomole level. The method is vastly simplified, compared with conventional approaches, and does not require...... preliminary separation of lipid classes or of individual molecular species, enzymatic digestion, or chemical derivatization. The approach was validated by the comparative analysis of the molecular composition of PCs from human red blood cells. In the total lipid extract of Madin-Darby canine kidney II cells...

  9. Reliable transport through a microfabricated X-junction surface-electrode ion trap

    CERN Document Server

    Wright, Kenneth; Faircloth, Daniel L; Volin, Curtis; Doret, S Charles; Hayden, Harley; Pai, C-S; Landgren, David W; Denison, Douglas; Killian, Tyler; Slusher, Richart E; Harter, Alexa W

    2012-01-01

    We report the design, fabrication, and characterization of a microfabricated surface-electrode ion trap that supports controlled transport through the two-dimensional intersection of linear trapping zones arranged in a ninety-degree cross. The trap is fabricated with very-large-scalable-integration (VLSI) techniques which are compatible with scaling to a larger quantum information processor. The shape of the radio-frequency (RF) electrodes is optimized with a genetic algorithm to minimize axial pseudopotential barriers and to minimize ion heating during transport. Seventy-eight independent DC control electrodes enable fine control of the trapping potentials. We demonstrate reliable ion transport between junction legs, trapping of ion chains with nearly-equal spacing in one of the trap's linear sections, and merging and splitting ions from these chains. Doppler-cooled ions survive more than 10^5 round-trip transits between junction legs without loss and more than sixty-five consecutive round trips without lase...

  10. Cascade emission in electron beam ion trap plasma

    CERN Document Server

    Jonauskas, Valda; Kyniene, Ausra; Kucas, Sigitas

    2013-01-01

    We present investigation of the influence of cascade emission to the formation of spectra from plasma created by electron beam ion trap (EBIT) in electron trapping mode. It has been shown that cascade emission can play an important role in the formation of spectra from the EBIT plasma. Process of the cascade emission takes place when ion having cycloidal orbit leaves electron beam where coronal approximation is applicable. Thus both processes - excitation from ground or metastable levels and cascade emission - take part in the population of levels. Demonstration is based on the investigation of $W^{13+}$ spectra. The present investigation helps to resolve long-standing discrepancies; in particular, the present structure of $W^{13+}$ spectra is in good agreement with measurements on electron beam ion trap. Lines in the experimental spectra are identified as $4f^{13} 5s 5p \\rightarrow 4f^{13} 5s^{2}$ and $4f^{12} 5s 5p^{2} \\rightarrow 4f^{12} 5s^{2} 5p$ transitions from Dirac-Fock-Slater calculations.

  11. A Scalable Microfabricated Ion Trap for Quantum Information Processing

    Science.gov (United States)

    Maunz, Peter; Haltli, Raymond; Hollowell, Andrew; Lobser, Daniel; Mizrahi, Jonathan; Rembetski, John; Resnick, Paul; Sterk, Jonathan D.; Stick, Daniel L.; Blain, Matthew G.

    2016-05-01

    Trapped Ion Quantum Information Processing (QIP) relies on complex microfabricated trap structures to enable scaling of the number of quantum bits. Building on previous demonstrations of surface-electrode ion traps, we have designed and characterized the Sandia high-optical-access (HOA-2) microfabricated ion trap. This trap features high optical access, high trap frequencies, low heating rates, and negligible charging of dielectric trap components. We have observed trap lifetimes of more than 100h, measured trap heating rates for ytterbium of less than 40quanta/s, and demonstrated shuttling of ions from a slotted to an above surface region and through a Y-junction. Furthermore, we summarize demonstrations of high-fidelity single and two-qubit gates realized in this trap. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under Contract DE-AC04-94AL85000. This work was supported by the Intelligence Advanced Research Projects Activity (IARPA).

  12. Laser desorption lamp ionization source for ion trap mass spectrometry.

    Science.gov (United States)

    Wu, Qinghao; Zare, Richard N

    2015-01-01

    A two-step laser desorption lamp ionization source coupled to an ion trap mass spectrometer (LDLI-ITMS) has been constructed and characterized. The pulsed infrared (IR) output of an Nd:YAG laser (1064 nm) is directed to a target inside a chamber evacuated to ~15 Pa causing desorption of molecules from the target's surface. The desorbed molecules are ionized by a vacuum ultraviolet (VUV) lamp (filled with xenon, major wavelength at 148 nm). The resulting ions are stored and detected in a three-dimensional quadrupole ion trap modified from a Finnigan Mat LCQ mass spectrometer operated at a pressure of ≥ 0.004 Pa. The limit of detection for desorbed coronene molecules is 1.5 pmol, which is about two orders of magnitude more sensitive than laser desorption laser ionization mass spectrometry using a fluorine excimer laser (157 nm) as the ionization source. The mass spectrum of four standard aromatic compounds (pyrene, coronene, rubrene and 1,4,8,11,15,18,22,25-octabutoxy-29H,31H-phthalocyanine (OPC)) shows that parent ions dominate. By increasing the infrared laser power, this instrument is capable of detecting inorganic compounds.

  13. A PRODUCT HYBRID GMRES ALGORITHM FOR NONSYMMETRIC LINEAR SYSTEMS

    Institute of Scientific and Technical Information of China (English)

    Bao-jiang Zhong

    2005-01-01

    It has been observed that the residual polynomials resulted from successive restarting cycles of GMRES(m) may differ from one another meaningfully. In this paper, it is further shown that the polynomials can complement one another harmoniously in reducing the iterative residual. This characterization of GMRES(m) is exploited to formulate an efficient hybrid iterative scheme, which can be widely applied to existing hybrid algorithms for solving large nonsymmetric systems of linear equations. In particular, a variant of the hybrid GMRES algorithm of Nachtigal, Reichel and Trefethen (1992) is presented. It is described how the new algorithm may offer significant performance improvements over the original one.

  14. Reliable transport through a microfabricated X-junction surface-electrode ion trap

    Science.gov (United States)

    Wright, Kenneth; Amini, Jason M.; Faircloth, Daniel L.; Volin, Curtis; Doret, S. Charles; Hayden, Harley; Pai, C.-S.; Landgren, David W.; Denison, Douglas; Killian, Tyler; Slusher, Richart E.; Harter, Alexa W.

    2013-03-01

    We report the design, fabrication and characterization of a microfabricated surface-electrode ion trap that supports controlled transport through the two-dimensional intersection of linear trapping zones arranged in a 90° cross. The trap is fabricated with very large scalable integration techniques which are compatible with scaling to a large quantum information processor. The shape of the radio-frequency electrodes is optimized with a genetic algorithm to reduce axial pseudopotential barriers and minimize ion heating during transport. Seventy-eight independent dc control electrodes enable fine control of the trapping potentials. We demonstrate reliable ion transport between junction legs and determine the rate of ion loss due to transport. Doppler-cooled ions survive more than 105 round-trip transits between junction legs without loss and more than 65 consecutive round trips without laser cooling.

  15. Conformation-specific spectroscopy of peptide fragment ions in a low-temperature ion trap.

    Science.gov (United States)

    Wassermann, Tobias N; Boyarkin, Oleg V; Paizs, Béla; Rizzo, Thomas R

    2012-06-01

    We have applied conformer-selective infrared-ultraviolet (IR-UV) double-resonance photofragment spectroscopy at low temperatures in an ion trap mass spectrometer for the spectroscopic characterization of peptide fragment ions. We investigate b- and a-type ions formed by collision-induced dissociation from protonated leucine-enkephalin. The vibrational analysis and assignment are supported by nitrogen-15 isotopic substitution of individual amino acid residues and assisted by density functional theory calculations. Under such conditions, b-type ions of different size are found to appear exclusively as linear oxazolone structures with protonation on the N-terminus, while a rearrangement reaction is confirmed for the a (4) ion in which the side chain of the C-terminal phenylalanine residue is transferred to the N-terminal side of the molecule. The vibrational spectra that we present here provide a particularly stringent test for theoretical approaches.

  16. Conformation-Specific Spectroscopy of Peptide Fragment Ions in a Low-Temperature Ion Trap

    Science.gov (United States)

    Wassermann, Tobias N.; Boyarkin, Oleg V.; Paizs, Béla; Rizzo, Thomas R.

    2012-06-01

    We have applied conformer-selective infrared-ultraviolet (IR-UV) double-resonance photofragment spectroscopy at low temperatures in an ion trap mass spectrometer for the spectroscopic characterization of peptide fragment ions. We investigate b- and a-type ions formed by collision-induced dissociation from protonated leucine-enkephalin. The vibrational analysis and assignment are supported by nitrogen-15 isotopic substitution of individual amino acid residues and assisted by density functional theory calculations. Under such conditions, b-type ions of different size are found to appear exclusively as linear oxazolone structures with protonation on the N-terminus, while a rearrangement reaction is confirmed for the a 4 ion in which the side chain of the C-terminal phenylalanine residue is transferred to the N-terminal side of the molecule. The vibrational spectra that we present here provide a particularly stringent test for theoretical approaches.

  17. Controlling trapping potentials and stray electric fields in a microfabricated ion trap through design and compensation

    CERN Document Server

    Doret, S Charles; Wright, Kenneth; Volin, Curtis; Killian, Tyler; Ozakin, Arkadas; Denison, Douglas; Hayden, Harley; Pai, C -S; Slusher, Richart E; Harter, Alexa W

    2012-01-01

    Recent advances in quantum information processing with trapped ions have demonstrated the need for new ion trap architectures capable of holding and manipulating chains of many (>10) ions. Here we present the design and detailed characterization of a new linear trap, microfabricated with scalable complementary metal-oxide-semiconductor (CMOS) techniques, that is well-suited to this challenge. Forty-four individually controlled DC electrodes provide the many degrees of freedom required to construct anharmonic potential wells, shuttle ions, merge and split ion chains, precisely tune secular mode frequencies, and adjust the orientation of trap axes. Microfabricated capacitors on DC electrodes suppress radio-frequency pickup and excess micromotion, while a top-level ground layer simplifies modeling of electric fields and protects trap structures underneath. A localized aperture in the substrate provides access to the trapping region from an oven below, permitting deterministic loading of particular isotopic/eleme...

  18. Observation and mitigation of ion trapping in Indus-2

    Indian Academy of Sciences (India)

    Saroj Jena; A D Ghodke

    2015-12-01

    The presence of trapped ions in electron storage rings causes considerable degradation in the performances of the beam, such as increase in beam size, reduction in beam lifetime, shifting of betatron tune, beam instabilities etc. This paper discusses the effects of ion trapping and its mitigation in Indus-2 electron storage ring. Ion-induced instability generating partial beam loss is one of the main barriers in higher beam current accumulation in any electron storage ring. Though there are several techniques to clear the ions from the electron beam path, in Indus-2, it is addressed mainly by filling the storage ring in partial bunch filling pattern. In order to improve the electron beam performance and to mitigate the ion-related problem, a suitable bunch filling pattern has been determined. The theoretical prediction and the result of optimal bunch filling pattern are presented in this paper.

  19. Precision measurements in ion traps using slowly moving standing waves

    CERN Document Server

    Walther, A; Singer, K; Schmidt-Kaler, F

    2011-01-01

    The present paper describes the experimental implementation of a measuring technique employing a slowly moving, near resonant, optical standing wave in the context of trapped ions. It is used to measure several figures of merit that are important for quantum computation in ion traps and which are otherwise not easily obtainable. Our technique is shown to offer high precision, and also in many cases using a much simpler setup than what is normally used. We demonstrate here measurements of i) the distance between two crystalline ions, ii) the Lamb-Dicke parameter, iii) temperature of the ion crystal, and iv) the interferometric stability of a Raman setup. The exact distance between two ions, in units of standing wave periods, is very important for motional entangling gates, and our method offers a practical way of calibrating this distance in the typical lab situation.

  20. Novel Ion Trap Design for Strong Ion-Cavity Coupling

    Directory of Open Access Journals (Sweden)

    Alejandro Márquez Seco

    2016-04-01

    Full Text Available We present a novel ion trap design which facilitates the integration of an optical fiber cavity into the trap structure. The optical fibers are confined inside hollow electrodes in such a way that tight shielding and free movement of the fibers are simultaneously achievable. The latter enables in situ optimization of the overlap between the trapped ions and the cavity field. Through numerical simulations, we systematically analyze the effects of the electrode geometry on the trapping characteristics such as trap depths, secular frequencies and the optical access angle. Additionally, we simulate the effects of the presence of the fibers and confirm the robustness of the trapping potential. Based on these simulations and other technical considerations, we devise a practical trap configuration that isviable to achieve strong coupling of a single ion.

  1. Utilization of MATLAB in Simulation of Linear Hybrid Circuits

    OpenAIRE

    BRANCIK, L.

    2003-01-01

    In the paper a MATLAB-based method for simulating transient phenomena in linear hybrid circuits containing parts with both lumped and distributed parameters is presented. Distributed parts of the circuit are multiconductor transmission lines, which can generally be nonuniform, with frequency-dependent parameters, and under nonzero initial voltage and/or current distributions. In principle a solution is formulated using the modified nodal analysis method in the frequency domain. Subsequently a...

  2. IMPROVEMENT OF THE CERN SPS ELECTROSTATIC SEPTA ION TRAPS

    CERN Multimedia

    Balhan, Bruno; Barlow, Roger Andrew; Raffaele, Graziano

    2016-01-01

    At CERN, the SPS synchrotron is equipped with a slow extraction channel towards the fixed target beam lines in the North Area This channel includes five consecutive electrostatic septa, where the field free region and the active high field region are separated by an array of tungsten-rhenium wires. The field-free region provides for the circulating beam, while the high field region is used to deflect the extracted beam. Since the residual gas can be ionized by the orbiting beam, low energy ions could cross the wire array and enter the high field region and cause high voltage breakdown when accelerated onto the cathode. To prevent low energy ions from entering this high electric field region, a vertical field is applied to the orbiting beam using so-called ‘ion traps’ for active protection. The vertical field is created by electrodes placed inside the region containing the circulating beam. Due to electromagnetic coupling onto the ion trap electrodes observed with the high frequency LHC beam (25 ns spaced ...

  3. An in situ trap capacitance measurement and ion-trapping detection scheme for a Penning ion trap facility

    Science.gov (United States)

    Reza, Ashif; Banerjee, Kumardeb; Das, Parnika; Ray, Kalyankumar; Bandyopadhyay, Subhankar; Dam, Bivas

    2017-03-01

    This paper presents the design and implementation of an in situ measurement setup for the capacitance of a five electrode Penning ion trap (PIT) facility at room temperature. For implementing a high Q resonant circuit for the detection of trapped electrons/ions in a PIT, the value of the capacitance of the trap assembly is of prime importance. A tunable Colpitts oscillator followed by a unity gain buffer and a low pass filter is designed and successfully implemented for a two-fold purpose: in situ measurement of the trap capacitance when the electric and magnetic fields are turned off and also providing RF power at the desired frequency to the PIT for exciting the trapped ions and subsequent detection. The setup is tested for the in situ measurement of trap capacitance at room temperature and the results are found to comply with those obtained from measurements using a high Q parallel resonant circuit setup driven by a standard RF signal generator. The Colpitts oscillator is also tested successfully for supplying RF power to the high Q resonant circuit, which is required for the detection of trapped electrons/ions.

  4. Characterization of Ni(II) complexes of Schiff bases of amino acids and (S)-N-(2-benzoylphenyl)-1-benzylpyrrolidine-2-carboxamide using ion trap and QqTOF electrospray ionization tandem mass spectrometry

    NARCIS (Netherlands)

    Jirasko, Robert; Holcapek, Michal; Kolarova, Lenka; Nadvornik, Milan; Popkov, Alexander

    2008-01-01

    This work demonstrates the application of electrospray ionization mass spectrometry (ESI-MS) using two different mass analyzers, ion trap and hybrid quadrupole time-of-flight (QqTOF) mass analyzer, for the structural characterization of Ni(II) complexes of Schiff bases of (S)-N-(2-benzoylphenyl)-1-b

  5. Characterization of Ni(II) complexes of Schiff bases of amino acids and (S)-N-(2-benzoylphenyl)-1-benzylpyrrolidine-2-carboxamide using ion trap and QqTOF electrospray ionization tandem mass spectrometry

    NARCIS (Netherlands)

    Jirasko, Robert; Holcapek, Michal; Kolarova, Lenka; Nadvornik, Milan; Popkov, Alexander

    This work demonstrates the application of electrospray ionization mass spectrometry (ESI-MS) using two different mass analyzers, ion trap and hybrid quadrupole time-of-flight (QqTOF) mass analyzer, for the structural characterization of Ni(II) complexes of Schiff bases of

  6. Mars Organic Molecule Analyzer (MOMA) Mass Spectrometer Flight Model and Future Ion Trap-Based Planetary Instruments

    Science.gov (United States)

    Brinckerhoff, W. B.; van Amerom, F. H. W.; Danell, R.; Pinnick, V. T.; Arevalo, R. D., Jr.; Li, X.; Grubisic, A.; Getty, S.; Hovmand, L.; Mahaffy, P. R.

    2015-12-01

    The Mars Organic Molecule Analyzer (MOMA) investigation on the 2018 ExoMars rover will examine the chemical composition of samples acquired from depths of up to two meters below the martian surface, where organics may be protected from radiative and oxidative degradation. MOMA combines pyrolysis gas chromatography mass spectrometry (GCMS) of bulk powder samples and Mars ambient laser desorption mass spectrometry (LDMS) surface analysis, using a single ion trap MS. This dual source design enables MOMA to detect compounds over a wide range of molecular weights and volatilities. The structure of any detected organics may be further examined using MOMA's tandem mass spectrometry (MS/MS) mode. The flight model (FM) ion trap sensor and electronics have been assembled under the extremely clean and sterile conditions required by ExoMars, and have met or exceeded all performance specifications during initial functional tests. After Mars ambient thermal cycling and calibration, the FM will be delivered as a subsystem of MOMA to rover integration in mid-2016. There MOMA will join complementary rover instruments such as the Raman and MicrOmega spectrometers designed to analyze common drill samples. Following the MOMA design, linear ion trap mass spectrometer (LITMS)-based instruments are under development for future missions. LITMS adds enhanced capabilities such as precision (point-by-point) analysis of drill cores, negative ion detection, a wider mass range, and higher temperature pyrolysis with precision evolved gas analysis, while remaining highly compact and robust. Each of the capabilities of LITMS has been demonstrated on breadboard hardware. The next phase will realize an end-to-end brassboard at flight scale that will meet stringent technology readiness level (TRL) 6 criteria, indicating readiness for development toward missions to Mars, comets, asteroids, outer solar system moons, and beyond.

  7. Ion trap system for radioactive ions at JYFL

    Energy Technology Data Exchange (ETDEWEB)

    Kolhinen, V.S.; Jokinen, A.; Rinta-Antila, S.; Szerypo, J. [University of Jyvaeskylae, Department of Physics (Finland); Aeystoe, J. [CERN, Geneva (Switzerland)

    2001-07-01

    The goal of the ion trap project in Jyvaeskylae is to improve the quality of radioactive beams at IGISOL (Ion Guide Isotope Separator On-Line), in terms of transverse emittance, energy spread and purity. This improvement is achieved with an aid of an RFQ cooler/buncher and a mass-selective cylindrical Penning trap (mass resolving power up to 10{sup 5}). Their final purpose is to produce cooled isobarically pure beams of exotic radioactivities mainly of exotic neutron-rich isotopes from fission (including refractory elements). In the Penning trap ions are confined in three dimensions in a superposition of static quadrupole electric and homogeneous magnetic fields. The magnetic field confines the ions in two dimensions in a plane perpendicular to the field direction. A confinement in the third, magnetic field direction (parallel to the trap axis) is done by a quadrupole electric field. The Penning trap system in Jyvaeskylae (JYFLTRAP) will contain two cylindrical Penning traps placed inside the same superconducting magnet (B=7 T). The first, purification trap, will accept cooled (continuous or bunched) beams from the RFQ cooler/buncher and perform the isobaric purification. The latter is - done using a combination of a buffer gas cooling and an azimuthal quadrupole RF-field providing mass- dependent centering of ions. This, in turn, allows mass-selective ejection of ions in short pulses. Clean monoisotopic bunched beams will be delivered for the nuclear spectroscopy studies, collinear laser spectroscopy experiments and precise nuclear mass measurements (10{sup -7} precision). The latter will be performed in the second, precision Penning trap (author)

  8. Direct trace analysis of metals and alloys in a quadrupole ion-trap mass spectrometer

    CERN Document Server

    Song, K S; Yang, M; Cha, H K; Lee, J M; Lee, G H

    1999-01-01

    An ion-trap mass spectrometer adopting a quadrupole ion-trap and laser ablation/ionization method was constructed. The developed system was tested for composition analysis of some metals (Cu, stainless), and alloys (hastalloy C, mumetal) by mass spectrometry. Samples were analyzed by using laser ablation from a sample probe tip followed by a mass analysis with the quadrupole ion-trap. The quadrupole ion-trap was modified to enable laser ablation by a XeCl excimer laser pulse that passed radially through the ring electrode. A mass scan of the produced ions was performed in the mass selective instability mode wherein trapped ions were successively detected by increasing the rf voltage through the ring electrode. Factors affecting the mass resolution, such as pressure of buffer gas and ablation laser power, are discussed.

  9. Investigation of glucosinolate profile and qualitative aspects in sprouts and roots of horseradish (Armoracia rusticana) using LC-ESI-hybrid linear ion trap with Fourier transform ion cyclotron resonance mass spectrometry and infrared multiphoton dissociation.

    Science.gov (United States)

    Agneta, Rosa; Rivelli, Anna Rita; Ventrella, Emanuela; Lelario, Filomena; Sarli, Giulio; Bufo, Sabino Aurelio

    2012-08-01

    Within the family of Brassicaceae, an important source of glucosinolates (GLSs) is represented by horseradish ( Armoracia rusticana P. Gaertner, B. Meyer & Scherbius), cultivated for its roots, which are grated fresh or processed into a sauce and used as a condiment. The characteristic pungent flavor of the root depends on the abundance of the bioactive GLS molecules. In crude plant extracts (sprouts and roots) of an accession of horseradish largely diffused in the Basilicata region (southern Italy), which develops many sprouts and produces white, fiery, and sharp-flavored marketable roots, we characterized the GLS profile by LC-ESI-LTQ-FTICR-MS and IRMPD. In sprouts and roots we identified 16 and 11 GLSs, respectively. We confirmed the presence of sinigrin, 4-hydroxyglucobrassicin, glucobrassicin, gluconasturtin, and 4-methoxyglucobrassicin and identified glucoiberin, gluconapin, glucocochlearin, glucoconringianin, glucosativin, glucoibarin, 5-hydroxyglucobrassicin, glucocapparilinearisin or glucobrassicanapin, glucotropaeolin, and glucoarabishirsutain, not previously characterized in horseradish. Of particular note was the presence of the putative 2-methylsulfonyl-oxo-ethyl-GLS.

  10. Hybrid Spectral Unmixing: Using Artificial Neural Networks for Linear/Non-Linear Switching

    Directory of Open Access Journals (Sweden)

    Asmau M. Ahmed

    2017-07-01

    Full Text Available Spectral unmixing is a key process in identifying spectral signature of materials and quantifying their spatial distribution over an image. The linear model is expected to provide acceptable results when two assumptions are satisfied: (1 The mixing process should occur at macroscopic level and (2 Photons must interact with single material before reaching the sensor. However, these assumptions do not always hold and more complex nonlinear models are required. This study proposes a new hybrid method for switching between linear and nonlinear spectral unmixing of hyperspectral data based on artificial neural networks. The neural networks was trained with parameters within a window of the pixel under consideration. These parameters are computed to represent the diversity of the neighboring pixels and are based on the Spectral Angular Distance, Covariance and a non linearity parameter. The endmembers were extracted using Vertex Component Analysis while the abundances were estimated using the method identified by the neural networks (Vertex Component Analysis, Fully Constraint Least Square Method, Polynomial Post Nonlinear Mixing Model or Generalized Bilinear Model. Results show that the hybrid method performs better than each of the individual techniques with high overall accuracy, while the abundance estimation error is significantly lower than that obtained using the individual methods. Experiments on both synthetic dataset and real hyperspectral images demonstrated that the proposed hybrid switch method is efficient for solving spectral unmixing of hyperspectral images as compared to individual algorithms.

  11. Hybrid proper orthogonal decomposition formulation for linear structural dynamics

    Science.gov (United States)

    Placzek, A.; Tran, D.-M.; Ohayon, R.

    2008-12-01

    Hybrid proper orthogonal decomposition (PODh) formulation is a POD-based reduced-order modeling method where the continuous equation of the physical system is projected on the POD modes obtained from a discrete model of the system. The aim of this paper is to evaluate the hybrid POD formulation and to compare it with other POD formulations on the simple case of a linear elastic rod subject to prescribed displacements in the perspective of building reduced-order models for coupled fluid-structure systems in the future. In the first part of the paper, the hybrid POD is compared to two other formulations for the response to an initial condition: an approach based on the discrete finite elements equation of the rod called the discrete POD (PODd), and an analytical approach using the exact solution of the problem and consequently called the analytical POD (PODa). This first step is useful to ensure that the PODh performs well with respect to the other formulations. The PODh is therefore used afterwards for the forced motion response where a displacement is imposed at the free end of the rod. The main contribution of this paper lies in the comparison of three techniques used to take into account the non-homogeneous Dirichlet boundary condition with the hybrid POD: the first method relies on control functions, the second on the penalty method and the third on Lagrange multipliers. Finally, the robustness of the hybrid POD is investigated on two examples involving firstly the introduction of structural damping and secondly a nonlinear force applied at the free end of the rod.

  12. Utilization of MATLAB in Simulation of Linear Hybrid Circuits

    Directory of Open Access Journals (Sweden)

    L. Brancik

    2003-12-01

    Full Text Available In the paper a MATLAB-based method for simulating transientphenomena in linear hybrid circuits containing parts with both lumpedand distributed parameters is presented. Distributed parts of thecircuit are multiconductor transmission lines, which can generally benonuniform, with frequency-dependent parameters, and under nonzeroinitial voltage and/or current distributions. In principle a solutionis formulated using the modified nodal analysis method in the frequencydomain. Subsequently an improved fast method of the numerical inversionof Laplace transforms in the vector or matrix form is applied to obtainsolution in the time domain.

  13. Printed circuit board ion trap mass analyzer: its structure and performance.

    Science.gov (United States)

    Jiang, Dan; Jiang, Gong-Yu; Li, Xiao-Xu; Xu, Fu-Xing; Wang, Liang; Ding, Li; Ding, Chuan-Fan

    2013-06-18

    An ion trap (IT) mass analyzer can be simply built with low cost material-the printed circuit board (PCB). A printed circuit board ion trap (PCBIT) can perform ion trapping, mass analysis, and tandem mass spectrometry as a conventional ion trap mass analyzer. In a PCBIT, each PCB electrode was fabricated to specially designed patterns with several separate electric strips. The strips' electrodes were insulated from each other and applied with different voltages during the experiment. Therefore, the electric field distribution inside the ion trap region may be adjusted and optimized by simply adjusting the voltage on each strip. The performance of the PCBIT can also be optimized since the property of an ion trap is strongly dependent on the field distribution. The fabrication, operation, and performance of the PCBIT are described and characterized in this paper. A prototype PCBIT was built with two pairs of 64 mm × 12 mm PCB rectangular plates and one pair of 10 mm × 10 mm stainless steel square plates. A mass analysis with a resolving power of over 1500 and a mass range of around 3000 Th was observed. The mass-selected isolation and collision-induced dissociation (CID) of ions were also tested using the homemade PCBIT system. The adjustable electric field distribution, simple structure, and low cost of PCBIT make it certainly suitable for the further miniaturization of the portable mass spectrometer.

  14. Quantitative analysis of cytokinins in plants by high performance liquid chromatography: electronspray ionization ion trap mass spectrometry.

    Science.gov (United States)

    Chen, Weiqi; Gai, Ying; Liu, Shichang; Wang, Renxiao; Jiang, Xiangning

    2010-10-01

    The present paper introduces a highly sensitive and selective method for simultaneous quantification of 12 cytokinins (free form and their conjugates). The method includes a protocol of extraction with methanol/water/formic acid (15/4/1, v/v/v) to the micro-scale samples, pre-purification with solid phase extraction (SPE) cartridges of the extracts, separation with a high performance liquid chromatography (HPLC) and detection by an electrospray ionization ion trap mass spectrometry (ESI-Ion trap-MS) system in a consecutive ion monitoring (CRM) mode at the three stage fragmentation of mass spectrometry (MS(3) ). The lowest detection level of the cytokinins of the method reaches 0.1-2.0 pg with a very wide range of linear regression from 1-512 pg, at the coefficient factors of 0.98-0.99. The feasibility of this method has been proven in the application of the method to the analysis of the trace-amount contents of cytokinins in the micro-scale samples of various types of plant materials, such as aerial parts of rice and poplar leaves etc. 12 endogenous cytokinins had been identified and quantified in the plant tissues, with an acceptable relatively higher recovery rate from 40% to 70%.

  15. Quantitative Analysis of Cytokinins in Plants by High Performance Liquid Chromatography: Electronspray Ionization Ion Trap Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    Weiqi Chen; Ying Gai; Shichang Liu; Renxiao Wang; Xiangning Jiang

    2010-01-01

    The present paper introduces a highly sensitive and selective method for simultaneous quantification of 12 cytokinins(free form and their conjugates).The method includes a protocol of extraction with methanol/water/formic acid(1514/1,v/v/v)to the micro-scale samples,pre-purification with solid phase extraction(SPE)cartridges of the extracts,separation with a high performance liquid chromatography(HPLC)and detection by an electrospray ionization ion trap mass spectrometry(ESI-Ion trap-MS)system in a consecutive ion monitoring(CRM)mode at the three stage fragmentation of mass spectrometry(MS3).The lowest detection level of the cytokinins of the method reaches 0.1-2.0 pg with a very wide range of linear regression from 1-512 pg,at the coefficient factors of 0.98-0.99.The feasibility of this method has been proven in the application of the method to the analysis of the trace-amount contents of cytokinins in the micro-scale samples of various types of plant materials,such as aerial parts of rice and poplar leaves etc.12 endogenous cytokinins had been identified and quantified in the plant tissues,with an acceptable relatively higher recovery rate from 40% to 70%.

  16. Development of a new method for the enantiomer specific determination of HBCD using an ion trap mass spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Gomara, Belen [Department of Instrumental Analysis and Environmental Chemistry, Institute of General Organic Chemistry (CSIC), Juan de la Cierva 3, 28006 Madrid (Spain)], E-mail: bgomara@iqog.csic.es; Lebron-Aguilar, Rosa [Institute of Physical Chemistry ' Rocasolano' (CSIC), Serrano 119, 28006 Madrid (Spain); Quintanilla-Lopez, Jesus Eduardo [Institute of Physical Chemistry ' Rocasolano' (CSIC), Serrano 119, 28006 Madrid (Spain); Departamento de Ingenieria Quimica Industrial y del Medio Ambiente, ETSI Industriales (UPM), Jose Gutierrez Abascal 2, 28006 Madrid (Spain); Gonzalez, Maria Jose [Department of Instrumental Analysis and Environmental Chemistry, Institute of General Organic Chemistry (CSIC), Juan de la Cierva 3, 28006 Madrid (Spain)

    2007-12-12

    An alternative method for the enantiomer specific determination of hexabromocyclododecanes (HBCD) by LC-ESI-MS/MS using an ion trap analyser is proposed. The method is based on the formation of a chlorine adduct (m/z 676.6) of the ({+-}){alpha}-, ({+-}){beta}-, and ({+-}){gamma}-HBCD enantiomers and their further fragmentation into their stable quasi-molecular ion (m/z 640.6). In this way, problems related to the ion trap low mass cutoff and variable amounts of other adduct peaks in the samples are solved. Parameters affecting separation, ionisation and MS/MS detection were studied. Method performance was also evaluated: calibration curves were found linear from 20 to 400 pg {mu}L{sup -1} for each enantiomer; detection limits ranged between 1.5 and 4.3 pg {mu}L{sup -1}; repeatability and reproducibility, expressed as relative standard deviation, were lower than 6% and 13%, respectively. The application to different types of spiked samples (pork meat, lean fish, and butter) pointed out the occurrence of matrix effects that could be solved by using labelled standards.

  17. [Determination of 21 fragrance allergens in toys by gas chromatography-ion trap mass spectrometry].

    Science.gov (United States)

    Lü, Qing; Zang, Qing; Bai, Hua; Li, Haiyu; Kang, Suyuan; Wang, Chao

    2012-05-01

    A method of gas chromatography-ion trap mass spectrometry (GC-IT-MS) was developed for the determination of 21 fragrance allergens in sticker toys, plush toys and plastic toys. The experimental conditions, such as sample pretreatment conditions, and the analytical conditions of GC-IT-MS, were optimized. The sticker toy samples and plush toy samples were extracted with acetone by ultrasonic wave, and the extracts were separated on an Agilent HP-1 MS column (50 m x 0.2 mm x 0.5 microm), then determined by IT-MS and quantified by external standard method. The plastic toy samples were extracted by the dissolution-precipitation approach, cleaned up with an Envi-carb solid phase extraction column and concentrated by rotary evaporation and nitrogen blowing, then determined by GC-IT-MS and quantified by external standard method. The calibration curves showed good linearity in the range of 0.002-50 mg/L with the correlation coefficients greater than 0.996 8. The limits of quantification (LOQ, S/N > 10) were 0.02-40 mg/kg. The average recoveries of the target compounds spiked in the sample at three concentration levels were in the range of 82.2%-110.8% with the relative standard deviations (RSDs) of 0.6%-10.5%. These results show that this method is accurate and sensitive for the qualitative and quantitative determination of the 21 fragrance allergens in the 3 types of toys.

  18. Determination of 48 fragrance allergens in toys using GC with ion trap MS/MS.

    Science.gov (United States)

    Lv, Qing; Zhang, Qing; Li, Wentao; Li, Haiyu; Li, Pi; Ma, Qiang; Meng, Xianshuang; Qi, Meiling; Bai, Hua

    2013-11-01

    This paper presents a method for the simultaneous determination of 48 fragrance allergens in four types of toys (plastic toys, play clays, plush toys, and paper toys) based on GC with ion trap MS/MS. Compared with single-stage MS, MS/MS is superior in terms of the qualification and quantification of a large range of compounds in complicated matrices. Procedures for extraction and purification were optimized for each toy type. The method proved to be linear over a wide range of concentrations for all analytes with correlation coefficients between 0.9768 and 0.9999. Validation parameters, namely, LODs and LOQs, ranged from 0.005-5.0 and from 0.02-20 mg/kg, respectively. Average recoveries of target compounds (spiked at three concentration levels) were in the range of 79.5-109.1%. Intraday and interday repeatabilities of the proposed method varied from 0.7-10.5% and from 3.1-13.4%, respectively. The proposed method was used to monitor fragrance allergens in commercial toy products. Our findings indicate that this method is an accurate and effective technique for analyzing fragrance allergens in materials composed of complex components.

  19. Integrated Fiber-Mirror Ion Trap for Strong Ion-Cavity Coupling

    CERN Document Server

    Brandstätter, Birgit; Schüppert, Klemens; Casabone, Bernardo; Friebe, Konstantin; Stute, Andreas; Schmidt, Piet O; Deutsch, Christian; Reichel, Jakob; Blatt, Rainer; Northup, Tracy E

    2013-01-01

    We present and characterize fiber mirrors and a miniaturized ion-trap design developed to integrate a fiber-based Fabry-Perot cavity (FFPC) with a linear Paul trap for use in cavity-QED experiments with trapped ions. Our fiber-mirror fabrication process not only enables the construction of FFPCs with small mode volumes, but also allows us to minimize the influence of the dielectric fiber mirrors on the trapped-ion pseudopotential. We discuss the effect of clipping losses for long FFPCs and the effect of angular and lateral displacements on the coupling efficiencies between cavity and fiber. Optical profilometry allows us to determine the radii of curvature and ellipticities of the fiber mirrors. From finesse measurements we infer a single-atom cooperativity of up to $12$ for FFPCs longer than $200 \\mu$m in length; comparison to cavities constructed with reference substrate mirrors produced in the same coating run indicates that our FFPCs have similar scattering losses. We discuss experiments to anneal fiber m...

  20. Design, microfabrication, and analysis of micrometer-sized cylindrical ion trap arrays

    Science.gov (United States)

    Cruz, D.; Chang, J. P.; Fico, M.; Guymon, A. J.; Austin, D. E.; Blain, M. G.

    2007-01-01

    A description of the design and microfabrication of arrays of micrometer-scale cylindrical ion traps is offered. Electrical characterization and initial ion trapping experiments with a massively parallel array of 5μm internal radius (r0) sized cylindrical ion traps (CITs) are also described. The ion trap, materials, and design are presented and shown to be critical in achieving minimal trapping potential while maintaining minimal power consumption. The ion traps, fabricated with metal electrodes, have inner radii of 1, 2, 5, and 10μm and range from 5to24μm in height. The electrical characteristics of packaged ion trap arrays were measured with a vector network analyzer. The testing focused on trapping toluene (C7H8), mass 91, 92, or 93amu, in the 5μm sized CITs. Ions were formed via electron impact ionization and were ejected by turning off the rf voltage applied to the ring electrode; a current signal was collected at this time. Optimum ionization and trapping conditions, such as a sufficient pseudopotential well and high ionization to ion loss rate ratio (as determined by simulation), proved to be difficult to establish due to the high device capacitance and the presence of exposed dielectric material in the trapping region. However, evidence was obtained suggesting the trapping of ions in 1%-15% of the traps in the array. These first tests on micrometer-scale CITs indicated the necessary materials and device design modifications for realizing ultrasmall and low power ion traps.

  1. Star-Shaped and Linear POSS-Polylactide Hybrid Copolymers

    Directory of Open Access Journals (Sweden)

    Krystyna Rozga-Wijas

    2015-07-01

    Full Text Available Novel octakis-2[(6-hydroxyhexylthio]ethyl-octasilsesquioxane (POSS-S-OH as well as heptaisobutyl-2[(6-hydroxyhexylthio]ethyl-octasilsesquioxane (iBu-POSS-S-OH were synthesized. POSS structures, bearing both types of groups i.e., 2[(6-hydroxyhexylthio]ethyl and the vinyl ones, pendant from the octahedral cage are also described. The synthetic pathway involved thiol-ene click reaction of 6-mercapto-1-hexanol (MCH to octavinyloctasilsesquioxane (POSS-Vi, and heptaisobutylvinyloctasilsesquioxane (iBu-POSS-Vi, in the presence of 2,2′-azobisisobutyronitrile. The functionalized silsesquioxane cages of regular octahedral structure were used further as initiators for ring opening polymerization of L,L-dilactide, catalyzed by tin (II 2-ethylhexanoate. The polymerization afforded biodegradable hybrid star shape and linear systems with an octasilsesquioxane cage as a core, bearing polylactide arm(s.

  2. Linear engine development for series hybrid electric vehicles

    Science.gov (United States)

    Toth-Nagy, Csaba

    This dissertation argues that diminishing oil reserves, concern over global climate change, and desire to improve ambient air quality all demand the development of environment-friendly personal transportation. In certain applications, series hybrid electric vehicles offer an attractive solution to reducing fuel consumption and emissions. Furthermore, linear engines are emerging as a powerplant suited to series HEV applications. In this dissertation, a linear engine/alternator was considered as the auxiliary power unit of a range extender series hybrid electric vehicle. A prototype linear engine/alternator was developed, constructed and tested at West Virginia University. The engine was a 2-stroke, 2-cylinder, dual piston, direct injection, diesel engine. Experiment on the engine was performed to study its behavior. The study variables included mass of the translator, amount of fuel injected, injection timing, load, and stroke with operating frequency and mechanical efficiency as the basis of comparison. The linear engine was analyzed in detail and a simple simulation model was constructed to compare the trends of simulation with the experimental data and to expand on the area where the experimental data were lacking. The simulation was based on a simple and analytical model, rather than a detailed and intensely numerical one. The experimental and theoretical data showed similar trends. Increasing translator mass decreased the operating frequency and increased compression ratio. Larger mass and increased compression ratio improved the ability of the engine to sustain operation and the engine was able to idle on less fuel injected into the cylinder. Increasing the stroke length caused the operating frequency to drop. Increasing fueling or decreasing the load resulted in increased operating frequency. This projects the possibility of using the operating frequency as an input for feedback control of the engine. Injection timing was varied to investigate two different

  3. Multiple Mass Analysis Using an Ion Trap Array (ITA) Mass Analyzer

    Science.gov (United States)

    Xiao, Yu; Chu, Yanqiu; Ling, Xing; Ding, Zhengzhi; Xu, Chongsheng; Ding, Li; Ding, Chuan-Fan

    2013-09-01

    A novel ion trap array (ITA) mass analyzer with six ion trapping and analyzing channels was investigated. It is capable of analyzing multiple samples simultaneously. The ITA was built with several planar electrodes made of stainless steel and 12 identical parallel zirconia ceramic substrates plated with conductive metal layers. Each two of the opposing ceramic electrode plates formed a boundary of an ion trap channel and six identical ion trapping and analyzing channels were placed in parallel without physical electrode between any two adjacent channels. The electric field distribution inside each channel was studied with simulation. The new design took the advantage of high precision machining attributable to the rigidity of ceramic, and the convenience of surface patterning technique. The ITA system was tested by using a two-channel electrospray ionization source, a multichannel simultaneous quadruple ion guide, and two detectors. The simultaneous analysis of two different samples with two adjacent ITA channels was achieved and independent mass spectra were obtained. For each channel, the mass resolution was tested. Additional ion trap functions such as mass-selected ion isolation and collision-induced dissociation (CID) were also tested. The results show that one ITA is well suited for multiple simultaneous mass analyses.

  4. Characteristics of Ion Activation and Collision Induced Dissociation Using Digital Ion Trap Technology

    Science.gov (United States)

    Xu, Fuxing; Dang, Qiankun; Dai, Xinhua; Fang, Xiang; Wang, Yuanyuan; Ding, Li; Ding, Chuan-Fan

    2016-08-01

    Collision induced dissociation (CID) is one of the most established techniques for tandem mass spectrometry analysis. The CID of mass selected ion could be realized by ion resonance excitation with a digital rectangular waveform. The method is simple, and highly efficient CID result could be obtained by optimizing the experimental parameters, such as digital waveform voltage, frequency, and q value. In this work, the relationship between ion trapping waveform voltage and frequency at preselected q value, the relationship between waveform frequency and the q value at certain ion trapping voltage for optimum CID efficiency were investigated. Experiment results showed that the max CID efficiency of precursor reserpine ions can be obtained at different trapping waveform voltage and frequency when q and β are different. Based on systematic experimental analysis, the optimum experimental conditions for high CID efficiency can be calculated at any selected β or q. By using digital ion trap technology, the CID process and efficient fragmentation of parent ions can be realized by simply changing the trapping waveform amplitude, frequency, and the β values in the digital ion trap mass spectrometry. The technology and method are simple. It has potential use in ion trap mass spectrometry.

  5. On the application of radio frequency voltages to ion traps via helical resonators

    CERN Document Server

    Siverns, J D; Weidt, S; Hensinger, W K

    2011-01-01

    Ions confined using a Paul trap require a stable, high voltage and low noise radio frequency (RF) potential. We present a guide for the design and construction of a helical coil resonator for a desired frequency that maximises the quality factor for a set of experimental constraints. We provide an in-depth analysis of the system formed from a shielded helical coil and an ion trap by treating the system as a lumped element model. This allows us to predict the resonant frequency and quality factor in terms of the physical parameters of the resonator and the properties of the ion trap. We also compare theoretical predictions with experimental data for different resonators, and predict the voltage applied to the ion trap as a function of the Q-factor, input power and the properties of the resonant circuit.

  6. A grooved planar ion trap design for scalable quantum information processing

    Institute of Scientific and Technical Information of China (English)

    Ji Wei-Bang; Wan Jin-Yin; Cheng Hua-Dong; Liu Liang

    2012-01-01

    We describe a new electrode design for a grooved surface-electrode ion trap,which is fabricated in printed-circuitboard technology with segmented electrodes.This design allows a laser beam to get through the central groove to avoid optical access blocking and laser scattering from the ion trap surface.The confining potentials are modeled both analytically and numerically.We optimize the radio frequency (rf) electrodes and dc electrodes to achieve the maximum trap depth for a given ion height above the trap electrodes.We also compare our design with the reality ion chip MI I for practical considerations.Comparison results show that our design is superior to MI I.This ion trap design may form the basis for large scale quantum computers or parallel quadrupole mass spectrometers.

  7. Integration of fluorescence collection optics with a microfabricated surface electrode ion trap

    CERN Document Server

    Brady, Gregory R; Moehring, David L; Stick, Daniel; Highstrete, Clark; Fortier, Kevin M; Blain, Matthew G; Haltli, Raymond A; Cruz-Cabrera, Alvaro A; Briggs, Ronald D; Wendt, Joel R; Carter, Tony R; Samora, Sally; Kemme, Shanalyn A

    2010-01-01

    We have successfully demonstrated an integrated optical system for collecting the fluorescence from a trapped ion. The system, consisting of an array of transmissive, dielectric micro-optics and an optical fiber array, has been intimately incorporated into the ion trapping chip without negatively impacting trapping performance. Considerations such as our choice of epoxies, vacuum feedthrough, and optical component materials did not degrade the vacuum environment, and we have demonstrated light detection as well as ion trapping and shuttling behavior comparable to trapping chips without integrated optics, with no modification to the control voltages of the trapping chip.

  8. Surface-activated chemical ionization ion trap mass spectrometry in the analysis of amphetamines in diluted urine samples.

    Science.gov (United States)

    Cristoni, Simone; Bernardi, Luigi Rossi; Gerthoux, Piermario; Gonella, Elisabetta; Mocarelli, Paolo

    2004-01-01

    A new ionization method, named surface-activated chemical ionization (SACI), was employed for the analysis of five amphetamines (3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyethylamphetamine (MDE), amphetamine and methamphetamine) by ion trap mass spectrometry. The results so obtained have been compared with those achieved by using atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) using the same instrument, clearly showing that SACI is the most sensitive of the three. The limit of detection and linearity range for SACI were compared with those obtained using APCI and ESI, showing that the new SACI approach provides the best results for both criteria. SACI was used to analyze MDA, MDMA MDE, amphetamine and methamphetamine in four urine samples, and the quantitation results are compared with those achieved using ESI.

  9. Detection of lysergic acid diethylamide (LSD) in urine by gas chromatography-ion trap tandem mass spectrometry.

    Science.gov (United States)

    Sklerov, J H; Kalasinsky, K S; Ehorn, C A

    1999-10-01

    A confirmatory method for the detection and quantitation of lysergic acid diethylamide (LSD) is presented. The method employs gas chromatography-tandem mass spectrometry (GC-MS-MS) using an internal ionization ion trap detector for sensitive MS-MS-in-time measurements of LSD extracted from urine. Following a single-step solid-phase extraction of 5 mL of urine, underivatized LSD can be measured with limits of quantitation and detection of 80 and 20 pg/mL, respectively. Temperature-programmed on-column injections of urine extracts were linear over the concentration range 20-2000 pg/mL (r2 = 0.999). Intraday and interday coefficients of variation were LSD-positive samples in this laboratory. Comparisons with alternate GC-MS methods and extraction procedures are discussed.

  10. Surface Planar Ion Chip for Linear Radio-Frequency Paul Traps

    Institute of Scientific and Technical Information of China (English)

    WAN Jin-Yin; QU Qiu-Zhi; ZHOU Zi-Chao; LI Xiao-Lin; WANG Yu-Zhu; LIU Liang

    2007-01-01

    We propose a surface planar ion chip which forms a linear radio frequency Paul ion trap. The electrodes reside in the two planes of a chip, and the trap axis is located above the chip surface. Its electric field and potential distribution are similar to the standard linear radio frequency Paul ion trap. This ion trap geometry may be greatly meaningful for quantum information processing.

  11. Advanced Automation for Ion Trap Mass Spectrometry-New Opportunities for Real-Time Autonomous Analysis

    Science.gov (United States)

    Palmer, Peter T.; Wong, C. M.; Salmonson, J. D.; Yost, R. A.; Griffin, T. P.; Yates, N. A.; Lawless, James G. (Technical Monitor)

    1994-01-01

    The utility of MS/MS for both target compound analysis and the structure elucidation of unknowns has been described in a number of references. A broader acceptance of this technique has not yet been realized as it requires large, complex, and costly instrumentation which has not been competitive with more conventional techniques. Recent advancements in ion trap mass spectrometry promise to change this situation. Although the ion trap's small size, sensitivity, and ability to perform multiple stages of mass spectrometry have made it eminently suitable for on-line, real-time monitoring applications, advance automation techniques are required to make these capabilities more accessible to non-experts. Towards this end we have developed custom software for the design and implementation of MS/MS experiments. This software allows the user to take full advantage of the ion trap's versatility with respect to ionization techniques, scan proxies, and ion accumulation/ejection methods. Additionally, expert system software has been developed for autonomous target compound analysis. This software has been linked to ion trap control software and a commercial data system to bring all of the steps in the analysis cycle under control of the expert system. These software development efforts and their utilization for a number of trace analysis applications will be described.

  12. Photoelectron emission as an alternative electron impact ionization source for ion trap mass spectrometry.

    Science.gov (United States)

    Gamez, Gerardo; Zhu, Liang; Schmitz, Thomas A; Zenobi, Renato

    2008-09-01

    Electron impact ionization has several known advantages; however, heated filament electron sources have pressure limitations and their power consumption can be significant for certain applications, such as in field-portable instruments. Herein, we evaluate a VUV krypton lamp as an alternative source for ionization inside the ion trap of a mass spectrometer. The observed fragmentation patterns are more characteristic of electron impact ionization than photoionization. In addition, mass spectra of analytes with ionization potentials higher than the lamp's photon energy (10.6 eV) can be easily obtained. A photoelectron impact ionization mechanism is suggested by the observed data allowed by the work function of the ion trap electrodes (4.5 eV), which is well within the lamp's photon energy. In this case, the photoelectrons emitted at the surface of the ion trap end-cap electrode are accelerated by the applied rf field to the ring electrode. This allows the photoelectrons to gain sufficient energy to ionize compounds with high ionization potentials to yield mass spectra characteristic of electron impact. In this manner, electron impact ionization can be used in ion trap mass spectrometers at low powers and without the limitations imposed by elevated pressures on heated filaments.

  13. Ion traps for precision experiments at rare-isotope-beam facilities

    Science.gov (United States)

    Kwiatkowski, Anna

    2016-09-01

    Ion traps first entered experimental nuclear physics when the ISOLTRAP team demonstrated Penning trap mass spectrometry of radionuclides. From then on, the demand for ion traps has grown at radioactive-ion-beam (RIB) facilities since beams can be tailored for the desired experiment. Ion traps have been deployed for beam preparation, from bunching (thereby allowing time coincidences) to beam purification. Isomerically pure beams needed for nuclear-structure investigations can be prepared for trap-assisted or in-trap decay spectroscopy. The latter permits studies of highly charged ions for stellar evolution, which would be impossible with traditional experimental nuclear-physics methods. Moreover, the textbook-like conditions and advanced ion manipulation - even of a single ion - permit high-precision experiments. Consequently, the most accurate and precise mass measurements are now performed in Penning traps. After a brief introduction to ion trapping, I will focus on examples which showcase the versatility and utility of the technique at RIB facilities. I will demonstrate how this atomic-physics technique has been integrated into nuclear science, accelerator physics, and chemistry. DOE.

  14. Practical aspects of trapped ion mass spectrometry, 5 applications of ion trapping devices

    CERN Document Server

    March, Raymond E

    2009-01-01

    Examines ion/neutral and ion/ion reactions, ion spectroscopy, and the structural characterization of proteins and peptides using quadropole ion trap mass spectrometry, Fourier transform - ion cyclotron resonance (FT-ICR) mass spectrometry, and traveling wave ion mobility mass spectrometry.

  15. Final Report - Advanced Ion Trap Mass Spectrometry Program - Oak Ridge National Laboratory - Sandia National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Whitten, W.B.

    2002-12-18

    This report covers the three main projects that collectively comprised the Advanced Ion Trap Mass Spectrometry Program. Chapter 1 describes the direct interrogation of individual particles by laser desorption within the ion trap mass spectrometer analyzer. The goals were (1) to develop an ''intelligent trigger'' capable of distinguishing particles of biological origin from those of nonbiological origin in the background and interferent particles and (2) to explore the capability for individual particle identification. Direct interrogation of particles by laser ablation and ion trap mass spectrometry was shown to have good promise for discriminating between particles of biological origin and those of nonbiological origin, although detailed protocols and operating conditions were not worked out. A library of more than 20,000 spectra of various types of biological particles has been assembled. Methods based on multivariate analysis and on neural networks were used to discriminate between particles of biological origin and those of nonbiological origin. It was possible to discriminate between at least some species of bacteria if mass spectra of several hundred similar particles were obtained. Chapter 2 addresses the development of a new ion trap mass analyzer geometry that offers the potential for a significant increase in ion storage capacity for a given set of analyzer operating conditions. This geometry may lead to the development of smaller, lower-power field-portable ion trap mass spectrometers while retaining laboratory-scale analytical performance. A novel ion trap mass spectrometer based on toroidal ion storage geometry has been developed. The analyzer geometry is based on the edge rotation of a quadrupolar ion trap cross section into the shape of a torus. Initial performance of this device was poor, however, due to the significant contribution of nonlinear fields introduced by the rotation of the symmetric ion-trapping geometry. These

  16. Analysis of VX on soil particles using ion trap secondary ion mass spectrometry.

    Science.gov (United States)

    Groenewold, G S; Appelhans, A D; Gresham, G L; Olson, J E; Jeffery, M; Wright, J B

    1999-07-01

    The direct detection of the nerve agent VX (methylphosphonothioic acid, S-[2-[bis(1-methylethyl)amino]ethyl] O-ethyl ester) on milligram quantities of soil particles has been achieved using ion trap secondary ion mass spectrometry (IT-SIMS). VX is highly adsorptive toward a wide variety of surfaces; this attribute makes detection using gas-phase approaches difficult but renders the compound very amenable to surface detection. An ion trap mass spectrometer, modified to perform SIMS, was employed in the present study. A primary ion beam (ReO4-) was fired on axis through the ion trap, where it impacted the soil particle samples. [VX + H]+, [VX + H]+ fragment ions, and ions from the chemical background were sputtered into the gas-phase environment of the ion trap, where they were either scanned out or isolated and fragmented (MS2). At a surface concentration of 0.4 monolayer, intact [VX + H]+, and its fragment ions, were readily observable above background. However, at lower concentrations, the secondary ion signal from VX became obscured by ions derived from the chemical background on the surface of the soil particles. MS2 analysis using the ion trap was employed to improve detection of lower concentrations of VX: detection of the 34S isotopic ion of [VX + H]+, present at a surface concentration of approximately 0.002 monolayer, was accomplished. The study afforded the opportunity to investigate the fragmentation chemistry of VX. Semiempirical calculations suggest strongly that the molecule is protonated at the N atom. Deuterium labeling showed that formation of the base peak ion (C2H4)N(i-C3H7)2+ involves transfer of the amino proton to the phosphonothioate moiety prior to, or concurrent with, C-S bond cleavage. To manage the risk associated with working with the compound, the vacuum unit of the IT-SIMS was located in a hood, connected by cables to the externally located electronics and computer.

  17. Coulomb crystal mass spectrometry in a digital ion trap

    CERN Document Server

    Deb, Nabanita; Smith, Alexander D; Keller, Matthias; Rennick, Christopher J; Heazlewood, Brianna R; Softley, Timothy P

    2015-01-01

    We present a mass spectrometric technique for identifying the masses and relative abundances of Coulomb-crystallized ions held in a linear Paul trap. A digital radiofrequency waveform is employed to generate the trapping potential, as this can be cleanly switched off, and static dipolar fields subsequently applied to the trap electrodes for ion ejection. Excellent detection efficiency is demonstrated for Ca+ and CaF+ ions from bi-component Ca+/CaF+ Coulomb crystals prepared by reaction of Ca+ with CH3F. A quantitative linear relationship is observed between ion number and the corresponding integrated TOF peak, independent of the ionic species. The technique is applicable to a diverse range of multi-component Coulomb crystals - demonstrated here for Ca+/NH3+/NH4+ and Ca+/CaOH+/CaOD+ crystals - and will facilitate the measurement of ion-molecule reaction rates and branching ratios in complicated reaction systems.

  18. Max-plus-linear model-based predictive control for constrained hybrid systems:linear programming solution

    Institute of Scientific and Technical Information of China (English)

    Yuanyuan ZOU; Shaoyuan LI

    2007-01-01

    In this paper,a linear programming method is proposed to solve model predictive control for a class of hybrid systems.Firstly,using the(max,+)algebra,a typical subclass of hybrid systems called max-plus-linear(MPL)systems is obtained.And then,model predictive control(MPC)framework is extended to MPL systems.In general,the nonlinear optimization approach or extended linear complementarity problem(ELCP)were applied to solve the MPL-MPC optimization problem.A new optimization method based on canonical forms for max-min-plus-scaling(MMPS)functions (using the operations maximization,minimization,addition and scalar multiplication)with linear constraints on the inputs is presented.The proposed approach consists in solving several linear programming problems and is more efficient than nonlinear optimization.The validity of the algorithm is illustrated by an example.

  19. Photoionization and Photoelectric Loading of Barium Ion Traps

    CERN Document Server

    Steele, A V; Churchill, L R; Griffin, P F

    2007-01-01

    Simple and effective techniques for loading barium ions into linear Paul traps are demonstrated. Two-step photoionization of neutral barium is achieved using a weak intercombination line (6s2 1S0 6s6p 3P1, 791 nm) followed by excitation above the ionization threshold using a nitrogen gas laser (337 nm). Isotopic selectivity is achieved by using a near Doppler-free geometry for excitation of the triplet 6s6p 3P1 state. Additionally, we report a particularly simple and efficient trap loading technique that employs an in-expensive UV epoxy curing lamp to generate photoelectrons.

  20. Stick-slip nanofriction in cold-ion traps

    Science.gov (United States)

    Mandelli, Davide; Vanossi, Andrea; Tosatti, Erio

    2013-03-01

    Trapped cold ions are known to form linear or planar zigzag chains, helices or clusters depending on trapping conditions. They may be forced to slide over a laser induced corrugated potential, a mimick of sliding friction. We present MD simulations of an incommensurate 101 ions chain sliding subject to an external electric field. As expected with increasing corrugation, we observe the transition from a smooth-sliding, highly lubric regime to a strongly dissipative stick-slip regime. Owing to inhomogeneity the dynamics shows features reminiscent of macroscopic frictional behaviors. While the chain extremities are pinned, the incommensurate central part is initially free to slide. The onset of global sliding is preceded by precursor events consisting of partial slips of chain portions further from the center. We also look for frictional anomalies expected for the chain sliding across the linear-zigzag structural phase transition. Although the chain is too short for a proper critical behavior, the sliding friction displays a frank rise near the transition, due to opening of a new dissipative channel via excitations of transverse modes. Research partly sponsored by Sinergia Project CRSII2 136287/1.

  1. Poly-anion production in Penning and RFQ ion traps

    Energy Technology Data Exchange (ETDEWEB)

    Bandelow, Steffi; Martinez, Franklin; Marx, Gerrit; Schweikhard, Lutz [Institute for Physics, Ernst-Moritz-Arndt University, 17487 Greifswald (Germany)

    2014-07-01

    The poly-anion production is being investigated in Penning and linear radio-frequency quadrupole (RFQ) traps at the ClusterTrap setup. The range of anionic charge states produced with the electron-bath technique in a Penning trap is restricted by the upper mass limit of this trap. By installation of a cylindrical Penning trap with a 12-Tesla superconducting magnet, the mass and thus cluster-size range is enhanced by a factor of 20 compared to the previously used hyperbolic 5-Tesla Penning trap. For first experimental tests with the 12-Tesla cylindrical Penning trap, gold cluster mono-anions Au{sup n-1}, n=330-350, have been exposed to an electron bath. As a result, higher negative charge states up to hexa-anionic clusters have been observed for the first time. In a parallel effort, di- and tri-anionic gold clusters have been produced in an RFQ-trap. To this end, an electron beam is guided through the RFQ-trap, which is operated by 2- or 3-state digital driving voltages. In addition, both polyanion-production techniques have been combined by pre-charging clusters in the RFQ-trap, transferring the resulting dianions into the Penning trap and applying the electron-bath technique to produce higher charge states.

  2. Development and Deployment of Retrofit PolarisQ Ion Trap Mass Spectrometer for Isotope Ratio Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, Cyril V. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Whitten, William B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-11-01

    This report describes Oak Ridge National Laboratory’s (ORNL) FY15 progress in support of National Nuclear Security Administration’s (NNSA) Portable Mass Spectrometer project. A retrofit PolarisQ ion trap mass spectrometer (RPMS) has been assembled from components of two PolarisQ ion trap mass spectrometers used in previous isotope ratio programs. The retrofit mass spectrometer includes a custom Hastelloy vacuum chamber which is about ¼ the size of the standard aluminum vacuum chamber and reduces the instrument weight from the original by nine pounds. In addition, the new vacuum chamber can be independently heated to reduce impurities such as water, which reacts with UF6 to produce HF in the vacuum chamber. The analyzer and all components requiring service are mounted on the chamber lid, facilitating quick and easy replacement of consumable components such as the filament and electron multiplier.

  3. Demonstration of integrated microscale optics in surface-electrode ion traps

    CERN Document Server

    Merrill, J True; Landgren, David; Amini, Jason M; Wright, Kenneth; Doret, S Charles; Pai, C-S; Hayden, Harley; Killian, Tyler; Faircloth, Daniel; Brown, Kenneth R; Harter, Alexa W; Slusher, Richart E

    2011-01-01

    In ion trap quantum information processing, efficient fluorescence collection is critical for fast, high-fidelity qubit detection and ion-photon entanglement. The expected size of future many-ion processors require scalable light collection systems. We report on the development and testing of a microfabricated surface-electrode ion trap with an integrated high numerical aperture (NA) micromirror for fluorescence collection. When coupled to a low NA lens, the optical system is inherently scalable to large arrays of mirrors in a single device. We demonstrate stable trapping and transport of 40Ca+ ions over a 0.63 NA micromirror and observe a factor of 1.9 enhancement in photon collection compared to the planar region of the trap.

  4. High Energy Laboratory Astrophysics Experiments using electron beam ion traps and advanced light sources

    Science.gov (United States)

    Brown, Gregory V.; Beiersdorfer, Peter; Bernitt, Sven; Eberle, Sita; Hell, Natalie; Kilbourne, Caroline; Kelley, Rich; Leutenegger, Maurice; Porter, F. Scott; Rudolph, Jan; Steinbrugge, Rene; Traebert, Elmar; Crespo-Lopez-Urritia, Jose R.

    2015-08-01

    We have used the Lawrence Livermore National Laboratory's EBIT-I electron beam ion trap coupled with a NASA/GSFC microcalorimeter spectrometer instrument to systematically address problems found in the analysis of high resolution X-ray spectra from celestial sources, and to benchmark atomic physics codes employed by high resolution spectral modeling packages. Our results include laboratory measurements of transition energies, absolute and relative electron impact excitation cross sections, charge exchange cross sections, and dielectronic recombination resonance strengths. More recently, we have coupled to the Max-Plank Institute for Nuclear Physics-Heidelberg's FLASH-EBIT electron beam ion trap to third and fourth generation advanced light sources to measure photoexcitation and photoionization cross sections, as well as, natural line widths of X-ray transitions in highly charged iron ions. Selected results will be presented.

  5. A quadrupole ion trap as low-energy cluster ion beam source

    CERN Document Server

    Uchida, N; Kanayama, T

    2003-01-01

    Kinetic energy distribution of ion beams was measured by a retarding field energy analyzer for a mass-selective cluster ion beam deposition system that uses a quadrupole ion trap as a cluster ion beam source. The results indicated that the system delivers a cluster-ion beam with energy distribution of approx 2 eV, which corresponded well to the calculation results of the trapping potentials in the ion trap. Using this deposition system, mass-selected hydrogenated Si cluster ions Si sub n H sub x sup + were actually deposited on Si(111)-(7x7) surfaces at impact kinetic energy E sub d of 3-30 eV. Observation by using a scanning tunneling microscope (STM) demonstrated that Si sub 6 H sub x sup + cluster ions landed on the surface without decomposition at E sub d =3 eV, while the deposition was destructive at E sub d>=18 eV. (author)

  6. Ion Trapping, Storage, and Ejection in Structures for Lossless Ion Manipulations.

    Science.gov (United States)

    Zhang, Xinyu; Garimella, Sandilya V B; Prost, Spencer A; Webb, Ian K; Chen, Tsung-Chi; Tang, Keqi; Tolmachev, Aleksey V; Norheim, Randolph V; Baker, Erin S; Anderson, Gordon A; Ibrahim, Yehia M; Smith, Richard D

    2015-06-16

    A new Structures for Lossless Ion Manipulations (SLIM) module, having electrode arrays patterned on a pair of parallel printed circuit boards (PCB), was constructed and utilized to investigate capabilities for ion trapping at a pressure of 4 Torr. Positive ions were confined by application of RF voltages to a series of inner rung electrodes with alternating phase on adjacent electrodes, in conjunction with positive DC potentials on surrounding guard electrodes on each PCB. An axial DC field was also introduced by stepwise varying the DC potentials applied to the inner rung electrodes to control the ion transport and accumulation inside the ion trapping region. We show that ions can be trapped and accumulated with up to 100% efficiency, stored for at least 5 h with no significant losses, and then could be rapidly ejected from the SLIM trap. The present results provide a foundation for the development of much more complex SLIM devices that facilitate extended ion manipulations.

  7. Demonstration of integrated microscale optics in surface-electrode ion traps

    Energy Technology Data Exchange (ETDEWEB)

    True Merrill, J; Brown, Kenneth R [Schools of Chemistry and Biochemistry, Computational Science and Engineering, and Physics, Georgia Institute of Technology, Atlanta, GA 30332 (United States); Volin, Curtis; Landgren, David; Amini, Jason M; Wright, Kenneth; Charles Doret, S; Pai, C-S; Hayden, Harley; Killian, Tyler; Faircloth, Daniel; Harter, Alexa W; Slusher, Richart E, E-mail: curtis.volin@gtri.gatech.edu [Georgia Tech Research Institute, Atlanta, GA 30332 (United States)

    2011-10-15

    In ion trap quantum information processing, efficient fluorescence collection is critical for fast, high-fidelity qubit detection and ion-photon entanglement. The expected size of future many-ion processors requires scalable light collection systems. We report on the development and testing of a microfabricated surface-electrode ion trap with an integrated high-numerical aperture (NA) micromirror for fluorescence collection. When coupled to a low-NA lens, the optical system is inherently scalable to large arrays of mirrors in a single device. We demonstrate the stable trapping and transport of {sup 40}Ca{sup +} ions over a 0.63 NA micromirror and observe a factor of 1.9 enhancement of photon collection compared to the planar region of the trap. (paper)

  8. Plug-and-Play Planar Ion Traps for Scalable Quantum Computation and Simulation

    Science.gov (United States)

    Amini, Jason; Denison, Douglas; Doret, S. Charles; Faircloth, Daniel; Hayden, Harley; Killian, Tyler; Landgren, David; Martin, Kevin; Merrill, True; Ozakin, Arkadas; Pai, C. S.; Shaikh, Fayaz; Shappert, Chris; Volin, Curtis; Wright, Ken; Harter, Alexa; Slusher, Richart

    2011-05-01

    At the heart of most ion-based quantum information processing and simulation efforts is an RF-Paul trap to confine the ion qubits. Cutting edge experiments are transitioning from a few qubits to a few tens of qubits with many more qubits envisioned for the future. The underlying ion traps need to both grow with the experiments and provide additional features that can simplify and extend these experiments. The Georgia Tech Research Institute (GTRI) is developing modeling and fabrication processes for these new generations of ion traps using silicon VLSI technology in surface- electrode geometries. Verified by detailed in-house trap characterization, GTRI has fabricated traps that approach the plug- and-play ideal and demonstrate reliable ion loading and transport, long dark lifetimes, and stable ion chains. Additional features are in development including junctions, integrated GHz range current guides for global qubit rotations, and micromirrors for light collection.

  9. Two-dimensional ion trap lattice on a microchip for quantum simulation

    CERN Document Server

    Sterling, R C; Weidt, S; Lake, K; Srinivasan, P; Webster, S C; Kraft, M; Hensinger, W K

    2013-01-01

    Using a controllable quantum system it is possible to simulate other highly complex quantum systems efficiently overcoming an in-principle limitation of classical computing. Trapped ions constitute such a highly controllable quantum system. So far, no dedicated architectures for the simulation of two-dimensional spin lattices using trapped ions in radio-frequency ion traps have been produced, limiting the possibility of carrying out such quantum simulations on a large scale. We report the operation of a two-dimensional ion trap lattice integrated in a microchip capable of implementing quantum simulations of two-dimensional spin lattices. Our device provides a scalable microfabricated architecture for trapping such ion lattices with coupling strengths between neighbouring ions sufficient to provide a powerful platform for the implementation of quantum simulations. In order to realize this device we developed a specialist fabrication process that allows for the application of very large voltages. We fabricated ...

  10. Ultraviolet Photodissociation Induced by Light-Emitting Diodes in a Planar Ion Trap.

    Science.gov (United States)

    Holden, Dustin D; Makarov, Alexander; Schwartz, Jae C; Sanders, James D; Zhuk, Eugene; Brodbelt, Jennifer S

    2016-09-26

    The first application of light-emitting diodes (LEDs) for ultraviolet photodissociation (UVPD) mass spectrometry is reported. LEDs provide a compact, low cost light source and have been incorporated directly into the trapping cell of an Orbitrap mass spectrometer. MS/MS efficiencies of over 50 % were obtained using an extended irradiation period, and UVPD was optimized by modulating the ion trapping parameters to maximize the overlap between the ion cloud and the irradiation volume.

  11. Evaporative cooling of highly charged ions in EBIT (Electron Beam Ion Trap): An experimental realization

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, M.B.; Levine, M.A.; Bennett, C.L.; Henderson, J.R.; Knapp, D.A.; Marrs, R.E.

    1988-12-01

    Both the total number and trapping lifetime of near-neon-like gold ions held in an electron beam ion trap have been greatly increased by a process of 'evaporative cooling'. A continuous flow of low-charge-state ions into the trap cools the high-charge-state ions in the trap. Preliminary experimental results using titanium ions as a coolant are presented. 8 refs., 6 figs., 2 tabs.

  12. Fused Silica Ion Trap Chip with Efficient Optical Collection System for Timekeeping, Sensing, and Emulation

    Science.gov (United States)

    2015-01-22

    sourcing, or in some ion trap applications, RF resonant detection. The walls of the high aspect slots and undercuts used to establish electrode...voltage test of these prototypes under vacuum did not result in any trace of breakdown (i.e. no observation of sparks or resonance jumps) even after...holes are characteristically conical . This geometry provides two benefits: it minimizes any limitation to the numerical aperture of the optics, and it

  13. Development of a Kingdon ion trap system for trapping externally injected highly charged ions.

    Science.gov (United States)

    Numadate, Naoki; Okada, Kunihiro; Nakamura, Nobuyuki; Tanuma, Hajime

    2014-10-01

    We have developed a Kingdon ion trap system for the purpose of the laboratory observation of the x-ray forbidden transitions of highly charged ions (HCIs). Externally injected Ar(q+) (q = 5-7) with kinetic energies of 6q keV were successfully trapped in the ion trap. The energy distribution of trapped ions is discussed in detail on the basis of numerical simulations. The combination of the Kingdon ion trap and the time-of-flight mass spectrometer enabled us to measure precise trapping lifetimes of HCIs. As a performance test of the instrument, we measured trapping lifetimes of Ar(q+) (q = 5-7) under a constant number density of H2 and determined the charge-transfer cross sections of Ar(q+)(q = 5, 6)-H2 collision systems at binary collision energies of a few eV. It was confirmed that the present cross section data are consistent with previous data and the values estimated by some scaling formula.

  14. Correlation between y-type ions observed in ion trap and triple quadrupole mass spectrometers.

    Science.gov (United States)

    Sherwood, Carly A; Eastham, Ashley; Lee, Lik Wee; Risler, Jenni; Vitek, Olga; Martin, Daniel B

    2009-09-01

    Multiple reaction monitoring mass spectrometry (MRM-MS) is a technique for high-sensitivity targeted analysis. In proteomics, MRM-MS can be used to monitor and quantify a peptide based on the production of expected fragment peaks from the selected peptide precursor ion. The choice of which fragment ions to monitor in order to achieve maximum sensitivity in MRM-MS can potentially be guided by existing MS/MS spectra. However, because the majority of discovery experiments are performed on ion trap platforms, there is concern in the field regarding the generalizability of these spectra to MRM-MS on a triple quadrupole instrument. In light of this concern, many operators perform an optimization step to determine the most intense fragments for a target peptide on a triple quadrupole mass spectrometer. We have addressed this issue by targeting, on a triple quadrupole, the top six y-ion peaks from ion trap-derived consensus library spectra for 258 doubly charged peptides from three different sample sets and quantifying the observed elution curves. This analysis revealed a strong correlation between the y-ion peak rank order and relative intensity across platforms. This suggests that y-type ions obtained from ion trap-based library spectra are well-suited for generating MRM-MS assays for triple quadrupoles and that optimization is not required for each target peptide.

  15. Liquid chromatography coupled with time-of-flight and ion trap mass spectrometry for qualitative analysis of herbal medicines

    Institute of Scientific and Technical Information of China (English)

    Xiao-Fei Chen; Hai-Tang Wu; Guang-Guo Tan; Zhen-Yu Zhu; Yi-Feng Chai

    2011-01-01

    With the expansion of herbal medicine (HM) market, the issue on how to apply up-to- date analytical tools on qualitative analysis of HMs to assure their quality, safety and efficacy has been arousing great attention. Due to its inherent characteristics of accurate mass measurements and multiple stages analysis, the integrated strategy of liquid chromatography (LC) coupled with time-of-flight mass spectrometry (TOF-MS) and ion trap mass spectrometry (IT-MS) is well-suited to be performed as qualitative analysis tool in this field. The purpose of this review is to provide an overview on the potential of this integrated strategy, including the review of general features of LC-IT-MS and LC-TOF-MS, the advantages of their combination, the common procedures for structure elucidation, the potential of LC-hybrid-IT-TOF/MS and also the summary and discussion of the applications of the integrated strategy for HM qualitative analysis (2006-2011). The advantages and future developments of LC coupled with IT and TOF-MS are highlighted.

  16. Application of Liquid Chromatography/Ion Trap Mass Spectrometry Technique to Determine Ergot Alkaloids in Grain Products

    Directory of Open Access Journals (Sweden)

    Krystyna Szymczyk

    2015-01-01

    Full Text Available A liquid chromatography/ion trap mass spectrometry-based method to determine six ergot alkaloids and their isomers is presented. The samples were cleaned on neutral alumina-based solid-phase extraction cartridges. The following method parameters were obtained (depending on the analyte and spiking level: method recovery from 63.0 to 104.6 %, relative standard deviation below 18 %, linear range from 1 to 325 μg/kg, linear correlation coefficient not less than 0.98. The developed analytical procedure was applied to determine the levels of ergot alkaloids in 65 samples of selected rye-based food products (flour– 34 samples, bran – 12 samples, rye – 18 samples, flakes – 1 sample. Measurable levels of alkaloids were found in majority of the analysed samples, particularly in rye flour. Additionally, alkaloids were determined in ergot sclerotia isolated from rye grains. Total content was nearly 0.01 % (97.9 mg/kg. However, the alkaloid profi le was dominated by ergocristine at 45.6 % (44.7 mg/kg, an alkaloid not commonly found in the tested food products. Ergocorninine at 0.2 % (0.2 mg/kg was the least abundant alkaloid.

  17. A generalized hybrid transfinite element computational approach for nonlinear/linear unified thermal/structural analysis

    Science.gov (United States)

    Tamma, Kumar K.; Railkar, Sudhir B.

    1987-01-01

    The present paper describes the development of a new hybrid computational approach for applicability for nonlinear/linear thermal structural analysis. The proposed transfinite element approach is a hybrid scheme as it combines the modeling versatility of contemporary finite elements in conjunction with transform methods and the classical Bubnov-Galerkin schemes. Applicability of the proposed formulations for nonlinear analysis is also developed. Several test cases are presented to include nonlinear/linear unified thermal-stress and thermal-stress wave propagations. Comparative results validate the fundamental capablities of the proposed hybrid transfinite element methodology.

  18. Evaluation of Pulse Counting for the Mars Organic Mass Analyzer (MOMA) Ion Trap Detection Scheme

    Science.gov (United States)

    Van Amerom, Friso H.; Short, Tim; Brinckerhoff, William; Mahaffy, Paul; Kleyner, Igor; Cotter, Robert J.; Pinnick, Veronica; Hoffman, Lars; Danell, Ryan M.; Lyness, Eric I.

    2011-01-01

    The Mars Organic Mass Analyzer is being developed at Goddard Space Flight Center to identify organics and possible biological compounds on Mars. In the process of characterizing mass spectrometer size, weight, and power consumption, the use of pulse counting was considered for ion detection. Pulse counting has advantages over analog-mode amplification of the electron multiplier signal. Some advantages are reduced size of electronic components, low power consumption, ability to remotely characterize detector performance, and avoidance of analog circuit noise. The use of pulse counting as a detection method with ion trap instruments is relatively rare. However, with the recent development of high performance electrical components, this detection method is quite suitable and can demonstrate significant advantages over analog methods. Methods A prototype quadrupole ion trap mass spectrometer with an internal electron ionization source was used as a test setup to develop and evaluate the pulse-counting method. The anode signal from the electron multiplier was preamplified. The an1plified signal was fed into a fast comparator for pulse-level discrimination. The output of the comparator was fed directly into a Xilinx FPGA development board. Verilog HDL software was written to bin the counts at user-selectable intervals. This system was able to count pulses at rates in the GHz range. The stored ion count nun1ber per bin was transferred to custom ion trap control software. Pulse-counting mass spectra were compared with mass spectra obtained using the standard analog-mode ion detection. Prelin1inary Data Preliminary mass spectra have been obtained for both analog mode and pulse-counting mode under several sets of instrument operating conditions. Comparison of the spectra revealed better peak shapes for pulse-counting mode. Noise levels are as good as, or better than, analog-mode detection noise levels. To artificially force ion pile-up conditions, the ion trap was overfilled

  19. Mass spectra of benzaldehyde using time resolved ion trapping mass spectrometer. Jikan bunkai ion trapping shitsuryo bunsekikei ni yoru benzaldehyde no mass spector

    Energy Technology Data Exchange (ETDEWEB)

    Ishigane, M.; Isa, K. (Fukui Univ., Fukui (Japan). Faculty of Education); Nishioka, K. (Fukui Univ., Fukui (Japan). Faculty of Engineering)

    1991-12-28

    An ion trapping mass spectrometer for time resolved analysis has been set up. The time resolved analysis function of this system is excellent and the ion detecting sensitivity is also high. Benzaldehyde is used as the specimen for the measurement of the A group of the mass spectra (m/z 105 106 and 107) by this system and similar mass spectra are obtained at delay time zero to those reported by now. Big changes are observed in the spectra when the delay times are varied. It is found that mass spectra which are different from those reported already are obtained when the mass spectrometer is pulse operated. In other words it can be said that the time dependence of the data on ion decomposition ( fragmentation) and ion/molecule reactions can be obtained in the state where solvent has no influence if this new system is adopted. 6 refs. 12 figs.

  20. Characterization of the human plasma phosphoproteome using linear ion trap mass spectrometry and multiple search engines.

    Science.gov (United States)

    Carrascal, Montserrat; Gay, Marina; Ovelleiro, David; Casas, Vanessa; Gelpí, Emilio; Abian, Joaquin

    2010-02-05

    Major plasma protein families play different roles in blood physiology and hemostasis and in immunodefense. Other proteins in plasma can be involved in signaling as chemical messengers or constitute biological markers of the status of distant tissues. In this respect, the plasma phosphoproteome holds potentially relevant information on the mechanisms modulating these processes through the regulation of protein activity. In this work we describe for the first time a collection of phosphopeptides identified in human plasma using immunoaffinity separation of the seven major serum protein families from other plasma proteins, SCX fractionation, and TiO(2) purification prior to LC-MS/MS analysis. One-hundred and twenty-seven phosphosites in 138 phosphopeptides mapping 70 phosphoproteins were identified with FDR < 1%. A high-confidence collection of phosphosites was obtained using a combined search with the OMSSA, SEQUEST, and Phenyx search engines.

  1. Preconditioning Schur Complement Systems of Highly-Indefinite Linear Systems for a Parallel Hybrid Solve

    Institute of Scientific and Technical Information of China (English)

    I.Yamazaki; X.S.Li; E.G.Ng

    2010-01-01

    A parallel hybrid linear solver based on the Schur complement method has the potential to balance the robustness of direct solvers with the efficiency of precon-ditioned iterative solvers. However, when solving large-scale highly-indefinite linear systems, this hybrid solver often suffers from either slow convergence or large memory requirements to solve the Schur complement systems. To overcome this challenge, we in this paper discuss techniques to preprocess the Schur complement systems in paral-lel. Numerical results of solving large-scale highly-indefinite linear systems from various applications demonstrate that these techniques improve the reliability and performance of the hybrid solver and enable efficient solutions of these linear systems on hundreds of processors, which was previously infeasible using existing state-of-the-art solvers.

  2. A selective and sensitive method for quantitation of lysergic acid diethylamide (LSD) in whole blood by gas chromatography-ion trap tandem mass spectrometry.

    Science.gov (United States)

    Libong, Danielle; Bouchonnet, Stéphane; Ricordel, Ivan

    2003-01-01

    A gas chromatography-ion trap tandem mass spectrometry (GC-ion trap MS-MS) method for detection and quantitation of LSD in whole blood is presented. The sample preparation process, including a solid-phase extraction step with Bond Elut cartridges, was performed with 2 mL of whole blood. Eight microliters of the purified extract was injected with a cold on-column injection method. Positive chemical ionization was performed using acetonitrile as reagent gas; LSD was detected in the MS-MS mode. The chromatograms obtained from blood extracts showed the great selectivity of the method. GC-MS quantitation was performed using lysergic acid methylpropylamide as the internal standard. The response of the MS was linear for concentrations ranging from 0.02 ng/mL (detection threshold) to 10.0 ng/mL. Several parameters such as the choice of the capillary column, the choice of the internal standard and that of the ionization mode (positive CI vs. EI) were rationalized. Decomposition pathways under both ionization modes were studied. Within-day and between-day stability were evaluated.

  3. Silylation of acrylamide for analysis by solid-phase microextraction/gas chromatography/ion-trap mass spectrometry.

    Science.gov (United States)

    Lagalante, Anthony F; Felter, Matthew A

    2004-06-16

    A method for quantitative analysis of acrylamide has been developed for use with headspace solid-phase microextraction (SPME). In the method, acrylamide undergoes silylation with N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) to form the volatile N,O-bis(trimethylsilyl)acrylamide (BTMSA). Once formed, BTMSA is readily extracted from the headspace over the silylation reaction using a 100 microm poly(dimethylsiloxane) SPME fiber. A series of experiments was undertaken to optimize the amount of BSTFA, the silylation reaction temperature, the silylation reaction duration, and SPME sampling duration to maximize the analytical sensitivity for BTMSA. Acrylamide levels were quantified relative to a [13C3]-acrylamide internal standard using gas chromatography/ion-trap mass spectrometry (GC/MS) in the single ion monitoring mode. An analytical working curve was constructed and found to be linear over the 4 to 6700 ppb acrylamide range investigated with a limit of detection of 0.9 ppb. The native acrylamide levels of three commercial cereals were measured using the optimized analytical method. Quantitative standard additions of acrylamide to the cereal matrixes demonstrated complete recovery of the spiked acrylamide.

  4. Simultaneous analysis of strychnine and brucine and their major metabolites by liquid chromatography-electrospray ion trap mass spectrometry.

    Science.gov (United States)

    Chen, Xueguo; Lai, Yongquan; Cai, Zongwei

    2012-04-01

    A liquid chromatography-electrospray ionization-ion trap mass spectrometry (LC-ESI-ITMS) method was developed for the simultaneous analysis of strychnine, brucine and their major metabolites. Strychnine and brucine were individually incubated with rat liver S9 fraction. The incubation samples were pooled together and analyzed with LC-ESI-ITMS in positive ion and full-scan detection mode. The calibration curves of strychnine and brucine in rat liver showed good linearity in ranges of 0.020 to 8.0 µg/mL for strychnine and 0.020 to 8.5 µg/mL for brucine. The limits of detections were both 0.008 µg/mL and the recoveries were 88.3 and 83.2% for strychnine and brucine, respectively. Two metabolites were identified as strychnine N-oxide and brucine N-oxide by comparing the molecular mass, retention time, full-scan mass spectra, tandem MS and MS(3) spectra with those of strychnine and brucine. The developed method provided high sensitivity and selectivity for the determination of poisonous alkaloids and their major metabolites and can be applied in the determination of samples in forensic and clinically toxicological cases.

  5. Characterization of underivatized lipid biomarkers from microorganisms with pyrolysis short-column gas chromatography/ion trap mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Snyder, A.P. (Army Chemical Research, Aberdeen Proving Ground, MD (USA)); McClennen, W.H.; Dworzanski, J.P.; Meuzelaar, H.L.C. (Univ. of Utah, Salt Lake City (USA))

    1990-12-01

    A microvolume Curie-point pyrolysis short-column (5 m) gas chromatography/mass spectrometry (Py-Gc/MS) procedure was developed for the characterization of various lipid moieties in microorganisms. High linear flow rates (approximately 175 cm/s) characterized the GC conditions in order to effect an efficient chromatographic transfer and elution of the underivatized diglycerides and monoglycerides, and small modifications were necessary to the ion trap MS system in order for it to accommodate the relatively high gas load. During a typical analysis run anhydrodiacylglycerides eluted within a 5-6-min time frame. Gram-positive bacilli and Gram-negative species were differentiated from each other by the pyrolysis patterns of their lipid components. In spite of the complexity of the analyte, a straightforward visual analysis was achieved with the aid of simple computerized data display procedures. These procedures included examination of (1) total ion current (TIC) profiles of the lipid region of the reconstructed chromatogram, (2) the integrated mass spectrum of this region, (3) selected reconstructed ion chromatograms (RICs), (4) RIC intensity distributions, and (5) corresponding mass spectra. An appealing aspect of the lipid data reduction procedure is that most of it can be accomplished visually without requiring computerized pattern recognition techniques.

  6. Imaging crystal spectrometer for high-resolution x-ray measurements on electron beam ion traps and tokamaks

    Science.gov (United States)

    Beiersdorfer, P.; Magee, E. W.; Hell, N.; Brown, G. V.

    2016-11-01

    We describe a crystal spectrometer implemented on the Livermore electron beam ion traps that employ two spherically bent quartz crystals and a cryogenically cooled back-illuminated charge-coupled device detector to measure x rays with a nominal resolving power of λ/Δλ ≥ 10 000. Its focusing properties allow us to record x rays either with the plane of dispersion perpendicular or parallel to the electron beam and, thus, to preferentially select one of the two linear x-ray polarization components. Moreover, by choice of dispersion plane and focussing conditions, we use the instrument either to image the distribution of the ions within the 2 cm long trap region, or to concentrate x rays of a given energy to a point on the detector, which optimizes the signal-to-noise ratio. We demonstrate the operation and utility of the new instrument by presenting spectra of Mo34+, which prepares the instrument for use as a core impurity diagnostic on the NSTX-U spherical torus and other magnetic fusion devices that employ molybdenum as plasma facing components.

  7. Electron Flood Charge Compensation Device for Ion Trap Secondary Ion Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Appelhans, Anthony David; Ward, Michael Blair; Olson, John Eric

    2002-11-01

    During secondary ion mass spectrometry (SIMS) analyses of organophosphorous compounds adsorbed onto soils, the measured anion signals were lower than expected and it was hypothesized that the low signals could be due to sample charging. An electron flood gun was designed, constructed and used to investigate sample charging of these and other sample types. The flood gun was integrated into one end cap of an ion trap secondary ion mass spectrometer and the design maintained the geometry of the self-stabilizing extraction optics used in this instrument. The SIMION ion optics program was used to design the flood gun, and experimental results agreed with the predicted performance. Results showed the low anion signals from the soils were not due to sample charging. Other insulating and conducting samples were tested using both a ReO4- and a Cs+ primary ion beam. The proximity of the sample and electron source to the ion trap aperture resulted in generation of background ions in the ion trap via electron impact (EI) ionization during the period the electron gun was flooding the sample region. When using the electron gun with the ReO4- primary beam, the required electron current was low enough that the EI background was negligible; however, the high electron flood current required with the Cs+ beam produced background EI ions that degraded the quality of the mass spectra. The consequences of the EI produced cations will have to be evaluated on a sample-by-sample basis when using electron flood. It was shown that the electron flood gun could be intentionally operated to produce EI spectra in this instrument. This offers the opportunity to measure, nearly simultaneously, species evaporating from a sample, via EI, and species bound to the surface, via SIMS.

  8. Progress towards precision measurements of beta-decay correlation parameters using atom and ion traps

    CERN Document Server

    Melconian, D; Fenker, B; Mehlman, M; Shidling, P D; Anholm, M; Ashery, D; Behr, J A; Gorelov, A; Gwinner, G; Olchankski, K; Smale, S

    2014-01-01

    The correlations of the decay products following the beta decay of nuclei have a long history of providing a low-energy probe of the fundamental symmetries of our universe. Over half a century ago, the correlation of the electrons following the decay of polarized 60Co demonstrated that parity is not conserved in weak interactions. Today, the same basic idea continues to be applied to search for physics beyond the standard model: make precision measurements of correlation parameters and look for deviations compared to their standard model predictions. Efforts to measure these parameters to the 0.1% level utilizing atom and ion trapping techniques are described.

  9. Recent trends in precision measurements of atomic and nuclear properties with lasers and ion traps

    Energy Technology Data Exchange (ETDEWEB)

    Block, Michael, E-mail: m.block@gsi.de [GSI Helmholtzzentrum für Schwerionenforschung GmbH (Germany)

    2017-11-15

    The X. international workshop on “Application of Lasers and Storage Devices in Atomic Nuclei Research” took place in Poznan in May 2016. It addressed the latest experimental and theoretical achievements in laser and ion trap-based investigations of radionuclides, highly charged ions and antiprotons. The precise determination of atomic and nuclear properties provides a stringent benchmark for theoretical models and eventually leads to a better understanding of the underlying fundamental interactions and symmetries. This article addresses some general trends in this field and highlights select recent achievements presented at the workshop. Many of these are covered in more detail within the individual contributions to this special issue of Hyperfine Interactions.

  10. Position and size of the electron beam in the high-energy electron beam ion trap

    CERN Document Server

    Utter, S B; López-Urrutia, J R C; Widmann, K

    1999-01-01

    In the last decade, many spectroscopic studies have been performed using the electron beam ion trap. Often these measurements rely on the electron beam as an effective slit, yet until now, no systematic study of the position and size of the electron beam under various operating conditions has been made. Here, we present a thorough study of the electron beam's position and size (and thus the electron density) as affected by various operating parameters, and give optimal parameter ranges for operating the device as a spectroscopic source. It is shown that the diameter is constant as the energy is varied, which is important for accurate cross-section measurements.

  11. An Integrated Mirror and Surface Ion Trap with a Tunable Trap Location

    CERN Document Server

    Van Rynbach, Andre; Kim, Jungsang

    2016-01-01

    We report a demonstration of a surface ion trap fabricated directly on a highly reflective mirror surface, which includes a secondary set of radio frequency (RF) electrodes allowing for translation of the quadrupole RF null location. We introduce a position-dependent photon scattering rate for a $^{174}$Yb$^+$ ion in the direction perpendicular to the trap surface using a standing wave of retroreflected light off the mirror surface directly below the trap. Using this setup, we demonstrate the capability of fine-tuning the RF trap location with nanometer scale precision and characterize the charging effects of the dielectric mirror surface upon exposure to ultra-violet light.

  12. Electron beam ion source and electron beam ion trap (invited)a)

    Science.gov (United States)

    Becker, Reinard; Kester, Oliver

    2010-02-01

    The electron beam ion source (EBIS) and its trap variant [electron beam ion trap (EBIT)] celebrated their 40th and 20th anniversary, respectively, at the EBIS/T Symposium 2007 in Heidelberg. These technologically challenging sources of highly charged ions have seen a broad development in many countries over the last decades. In contrast to most other ion sources the recipe of improvement was not "sorcery" but a clear understanding of the physical laws and obeying the technological constraints. This review will report important achievements of the past as well as promising developments in the future.

  13. Evaluation of ion trap mass spectrometry for the determination of ambient nicotine

    Energy Technology Data Exchange (ETDEWEB)

    Wise, M.B.; Higgins, C.E.; Ilgner, R.H.; Guerin, M.R.

    1989-01-01

    A thermal desorption unit has been interfaced directly with a Finnigan Ion Trap mass spectrometer (ITMS) for the identification and quantification of trace organics in air. No chromatographic separation of the desorbed constituents is performed prior to introduction into the mass spectrometer. Instead, positive identification of a compound is made based on its collision induced dissociation (CID) tandem (MS/MS) mass spectrum. Using this technique, as little as 50 pg of a constituent desorbed from resin trap can be characterized and quantified with a sample turnaround time of only 2--3 minutes. 3 refs.

  14. CrossRef Space-charge effects in Penning ion traps

    CERN Document Server

    Porobić, T; Breitenfeldt, M; Couratin, C; Finlay, P; Knecht, A; Fabian, X; Friedag, P; Fléchard, X; Liénard, E; Ban, G; Zákoucký, D; Soti, G; Van Gorp, S; Weinheimer, Ch; Wursten, E; Severijns, N

    2015-01-01

    The influence of space-charge on ion cyclotron resonances and magnetron eigenfrequency in a gas-filled Penning ion trap has been investigated. Off-line measurements with View the MathML source using the cooling trap of the WITCH retardation spectrometer-based setup at ISOLDE/CERN were performed. Experimental ion cyclotron resonances were compared with ab initio Coulomb simulations and found to be in agreement. As an important systematic effect of the WITCH experiment, the magnetron eigenfrequency of the ion cloud was studied under increasing space-charge conditions. Finally, the helium buffer gas pressure in the Penning trap was determined by comparing experimental cooling rates with simulations.

  15. Entanglement concentration and teleportation of multipartite entangled states in an ion trap

    Institute of Scientific and Technical Information of China (English)

    Pan Chang-Ning; Fang Mao-Fa

    2007-01-01

    We propose an effective scheme for the entanglement concentration of a four-particle state via entanglement swapping in an ion trap. Taking the maximally entangled state after concentration as a quantum channel, we can faithfully and determinatively teleport quantum entangled states from Alice to Bob without the joint Bell-state measurement. In the process of constructing the quantum channel, we adopt entanglement swapping to avoid the decrease of entanglement during the distribution of particles. Thus our scheme provides a new prospect for quantum teleportation over a longer distance. Furthermore, the success probability of our scheme is 1.0.

  16. UV-sensitive superconducting nanowire single photon detectors for integration in an ion trap

    CERN Document Server

    Slichter, D H; Leibfried, D; Mirin, R P; Nam, S W; Wineland, D J

    2016-01-01

    We demonstrate superconducting nanowire single photon detectors with 76 +/- 4 % system detection efficiency at a wavelength of 315 nm and an operating temperature of 3.2 K, with a background count rate below 1 count per second at saturated detection efficiency. We propose integrating these detectors into planar surface electrode radio-frequency Paul traps for use in trapped ion quantum information processing. We operate detectors integrated into test ion trap structures at 3.8 K both with and without typical radio-frequency trapping electric fields. The trapping fields reduce system detection efficiency by 9 %, but do not increase background count rates.

  17. Linear Viscoelasticity of Spherical SiO 2 Nanoparticle-Tethered Poly(butyl acrylate) Hybrids

    KAUST Repository

    Goel, Vivek

    2010-12-01

    The melt state linear viscoelastic properties of spherical silica nanoparticles with grafted poly(n-butyl acrylate) chains of varying molecular weight were probed using linear small amplitude dynamic oscillatory measurements and complementary linear stress relaxation measurements. While the pure silica-tethered-polymer hybrids with no added homopolymer exhibit solid-like response, addition of matched molecular weight free matrix homopolymer chains to this hybrid, at low concentrations of added homopolymer, maintains the solid-like response with a lowered modulus that can be factored into a silica concentration dependence and a molecular weight dependence. While the silica concentration dependence of the modulus is strong, the dependence on molecular weight is weak. On the other hand, increasing the amount of added homopolymer changes the viscoelastic response to that of a liquid with a relaxation time that scales exponentially with hybrid concentration. © 2010 American Chemical Society.

  18. Exciton dynamics and non-linearities in two-dimensional hybrid organic perovskites

    Science.gov (United States)

    Abdel-Baki, K.; Boitier, F.; Diab, H.; Lanty, G.; Jemli, K.; Lédée, F.; Garrot, D.; Deleporte, E.; Lauret, J. S.

    2016-02-01

    Due to their high potentiality for photovoltaic applications or coherent light sources, a renewed interest in hybrid organic perovskites has emerged for few years. When they are arranged in two dimensions, these materials can be considered as hybrid quantum wells. One consequence of the unique structure of 2D hybrid organic perovskites is a huge exciton binding energy that can be tailored through chemical engineering. We present experimental investigations of the exciton non-linearities by means of femtosecond pump-probe spectroscopy. The exciton dynamics is fitted with a bi-exponential decay with a free exciton life-time of ˜100 ps. Moreover, an ultrafast intraband relaxation (energy.

  19. Technology for On-Chip Qubit Control with Microfabricated Surface Ion Traps

    Energy Technology Data Exchange (ETDEWEB)

    Highstrete, Clark [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Quantum Information Sciences Dept.; Scott, Sean Michael [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). RF/Optoelectronics Dept.; Nordquist, Christopher D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). RF/Optoelectronics Dept.; Sterk, Jonathan David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Photonic Microsystem Technologies Dept.; Maunz, Peter Lukas Wilhelm [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Photonic Microsystem Technologies Dept.; Tigges, Christopher P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Photonic Microsystem Technologies Dept.; Blain, Matthew Glenn [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Photonic Microsystem Technologies Dept.; Heller, Edwin J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Microsystems Integration Dept.; Stevens, James E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). MESAFab Operations 2 Dept.

    2013-11-01

    Trapped atomic ions are a leading physical system for quantum information processing. However, scalability and operational fidelity remain limiting technical issues often associated with optical qubit control. One promising approach is to develop on-chip microwave electronic control of ion qubits based on the atomic hyperfine interaction. This project developed expertise and capabilities at Sandia toward on-chip electronic qubit control in a scalable architecture. The project developed a foundation of laboratory capabilities, including trapping the 171Yb+ hyperfine ion qubit and developing an experimental microwave coherent control capability. Additionally, the project investigated the integration of microwave device elements with surface ion traps utilizing Sandia’s state-of-the-art MEMS microfabrication processing. This effort culminated in a device design for a multi-purpose ion trap experimental platform for investigating on-chip microwave qubit control, laying the groundwork for further funded R&D to develop on-chip microwave qubit control in an architecture that is suitable to engineering development.

  20. Implementation of the Deutsch-Jozsa algorithm on an ion-trap quantum computer.

    Science.gov (United States)

    Gulde, Stephan; Riebe, Mark; Lancaster, Gavin P T; Becher, Christoph; Eschner, Jürgen; Häffner, Hartmut; Schmidt-Kaler, Ferdinand; Chuang, Isaac L; Blatt, Rainer

    2003-01-02

    Determining classically whether a coin is fair (head on one side, tail on the other) or fake (heads or tails on both sides) requires an examination of each side. However, the analogous quantum procedure (the Deutsch-Jozsa algorithm) requires just one examination step. The Deutsch-Jozsa algorithm has been realized experimentally using bulk nuclear magnetic resonance techniques, employing nuclear spins as quantum bits (qubits). In contrast, the ion trap processor utilises motional and electronic quantum states of individual atoms as qubits, and in principle is easier to scale to many qubits. Experimental advances in the latter area include the realization of a two-qubit quantum gate, the entanglement of four ions, quantum state engineering and entanglement-enhanced phase estimation. Here we exploit techniques developed for nuclear magnetic resonance to implement the Deutsch-Jozsa algorithm on an ion-trap quantum processor, using as qubits the electronic and motional states of a single calcium ion. Our ion-based implementation of a full quantum algorithm serves to demonstrate experimental procedures with the quality and precision required for complex computations, confirming the potential of trapped ions for quantum computation.

  1. Direct sampling ion trap mass spectrometry (DSITMS). Innovative technology summary report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-01

    This report describes the cost, performance, and other key characteristics of an innovative technology for determining the presence or absence, and measuring the concentration, of volatile organic compounds (VOCs) and semi-volatile organic compounds (SVOCs) in groundwater and soil, and in gaseous remediation process streams at hazardous waste sites. This new technology is Direct Sampling Ion Trap Mass Spectrometry (DSITMS). DSITMS introduces sample materials directly into an ion trap mass spectrometer by means of a very simple interface, such as a capillary restrictor or a polymer membrane. There is typically very little, if any, sample preparation and no chromatographic separation of the sample constituents. This means that the response of the instrument to the analytes or contaminants in a sample is nearly instantaneous, and that analytical methods based on DSITMS are fast. Analyses are typically completed in less than five minutes, and the analysis cost is generally 50% or less than the amount charged by commercial laboratories using Environmental Protection Agency (EPA) analysis methods.

  2. Cross-species gates in a Ba/Yb ion trap for modular networked quantum computing

    Science.gov (United States)

    Lichtman, Martin; Inlek, Ismail; Crocker, Clay; Sosnova, Ksenia; Monroe, Chris

    2016-05-01

    A modular network of many ion traps is a promising approach to building a scalable quantum computer. Generation of entanglement between remote atomic qubits has been demonstrated using interference of simultaneously emitted photons from one qubit in each trap. However, stray photons emitted during this process may corrupt information stored in nearby qubits. To avoid this problem we have implemented co-trapping of two different elements in the same ion trap. 171 Yb+ is used as a quantum memory and processor, while 138 Ba+ is used for communication. The 493 nm photons from Ba+ do not couple to the Yb+ system, and suffer less attenuation in fiber optics than wavelengths available from most commonly trapped ion species. In this talk we report demonstration of state mapping between the Yb+ and Ba+ internal qubits, and progress towards utilizing these techniques in entanglement of remote qubits. This work is supported by the ARO with funding from the IARPA MQCO program, the DARPA Quiness program, the AFOSR MURI on Quantum Transduction, and the ARL Center for Distributed Quantum Information.

  3. Analysis of six relevant toxaphene congeners in biological samples using ion trap MS/MS.

    Science.gov (United States)

    Gouteux, Bruno; Lebeuf, Michel; Trottier, Steve; Gagné, Jean-Pierre

    2002-10-01

    The quantification of six polychlorinated bornanes (CHBs) was studied using ion trap MS/MS. The significance of the selection of parent ions (Ip) and daughter ions (Id) on the detection of these toxaphene congeners was assessed in standard solution and biological samples. Our results indicate that different Ip and Id, selected at either low or high mass-to-charge (m/z) ratios, influence drastically the response factor of the CHBs and the chemical noise observed. For the octachlorinated toxaphene congeners (Parlar-26 (P-26), Parlar-40/41 (P-40/41), Parlar-44 (P-44)), the detection performance of the ion trap MS/MS is similar whether Ip and Id were chosen at low or high m/z ratios. However, the selection of Ip and Id at high m/z ratios clearly enhances the detection of the nonachlorinated toxaphene congeners (Parlar-50 (P-50), Parlar-62 (P-62)). The improved method, which selects Ip and Id at low m/z ratios for P-26, P-40/41 and P-44 and at high m/z ratios for P-50 and P-62, permitted to obtain low detection limits as well as repeatable and accurate results.

  4. MEMS Fabrication of Micro Cylindrical Ion Trap Mass Spectrometer for CubeSats Application

    Science.gov (United States)

    Zheng, Y.

    2015-10-01

    Microelectromechanical Systems (MEMS) technology is used to fabricate arrays of micro Cylindrical Ion Traps (μCIT) which are integrated into a miniaturized mass spectrometer (MS). The micro μCITs are built from silicon wafers and requires high machining precision, smooth surface, and high dimensional uniformity across the array for optimum mass spectrometer performance. In order to build these 3D miniature structures several MEMS processing techniques were explored and a process was developed and tested. By using the developed MEMS process, the required μCIT 4 x 4 arrays were fabricated. This included a chip design variation in which mechanical locking pits and posts were machined in the Ring Electrode (RE) chip and End Plate (EP) chips respectively, for self-assembly. The size of the assembled μCIT is only 12 mm x 12 mm x 1.5 mm. It is a key component for the miniature mass spectrometer. The micro cylindrical ion trap mass spectrometer has the advantages of low-power operation, simpler electronics and less-stringent vacuum system requirements. The MEMS batch production capabilities will also greatly lower the cost. It is a promising candidate for CubeSat and nanoSats applications for exploration of chemical distributions in space.

  5. Studies of highly charged iron ions using electron beam ion traps for interpreting astrophysical spectra

    Science.gov (United States)

    Brown, G. V.; Beilmann, C.; Bernitt, S.; Clementson, J.; Eberle, S.; Epp, S. W.; Graf, A.; Hell, N.; Kelley, R. L.; Kilbourne, C. A.; Kubiček, K.; Leutenegger, M. A.; Mäckel, V.; Porter, F. S.; Rudolph, J. K.; Simon, M. C.; Steinbrügge, R.; Träbert, E.; Ullrich, J.; Crespo López-Urrutia, J. R.; Beiersdorfer, P.

    2013-09-01

    For over a decade, the x-ray astrophysics community has enjoyed a fruitful epoch of discovery largely as a result of the successful launch and operation of the high resolution, high sensitivity spectrometers on board the Chandra, XMM-Newton and Suzaku x-ray observatories. With the launch of the x-ray calorimeter spectrometer on the Astro-H x-ray observatory in 2014, the diagnostic power of high resolution spectroscopy will be extended to some of the hottest, largest and most exotic objects in our Universe. The diagnostic utility of these spectrometers is directly coupled to, and often limited by, our understanding of the x-ray production mechanisms associated with the highly charged ions present in the astrophysical source. To provide reliable benchmarks of theoretical calculations and to address specific problems facing the x-ray astrophysics community, electron beam ion traps have been used in laboratory astrophysics experiments to study the x-ray signatures of highly charged ions. A brief overview of the EBIT-I electron beam ion trap operated at Lawrence Livermore National Laboratory and the Max-Planck-Institut für Kernphysik's FLASH-EBIT operated at third and fourth generation advanced light sources, including a discussion of some of the results are presented.

  6. Analysis of thermal radiation in ion traps for optical frequency standards

    CERN Document Server

    Doležal, Miroslav; Nisbet-Jones, Peter B R; King, Steven A; Jones, Jonathan M; Klein, Hugh A; Gill, Patrick; Lindvall, Thomas; Wallin, Anders E; Merimaa, Mikko; Tamm, Christian; Sanner, Christian; Huntemann, Nils; Scharnhorst, Nils; Leroux, Ian D; Schmidt, Piet O; Burgermeister, Tobias; Mehlstäubler, Tanja E; Peik, Ekkehard

    2015-01-01

    In many of the high-precision optical frequency standards with trapped atoms or ions that are under development to date, the AC Stark shift induced by thermal radiation leads to a major contribution to the systematic uncertainty. We present an analysis of the inhomogeneous thermal environment experienced by ions in various types of ion traps. Finite element models which allow the determination of the temperature of the trap structure and the temperature of the radiation were developed for 5 ion trap designs, including operational traps at PTB and NPL and further optimized designs. Models were refined based on comparison with infrared camera measurement until an agreement of better than 10% of the measured temperature rise at critical test points was reached. The effective temperature rises of the radiation seen by the ion range from 0.8 K to 2.1 K at standard working conditions. The corresponding fractional frequency shift uncertainties resulting from the uncertainty in temperature are in the 10-18 range for ...

  7. Characterization of phosphoantigens by high-performance anion-exchange chromatography-electrospray ionization ion trap mass spectrometry and nanoelectrospray ionization ion trap mass spectrometry.

    Science.gov (United States)

    Pont, F; Luciani, B; Belmant, C; Fournié, J J

    2001-08-01

    New phosphorylated microbial metabolites referred to as phosphoantigens activate immune responses in humans. Although these molecules have leading applications in medical research, no direct method allows their rapid and unambiguous structural identification. Here, we interfaced online HPAEC (high performance anion-exchange chromatography) with ESI-ITMS (electrospray ionization ion trap mass spectrometry) to identify such pyrophosphorylated molecules. A self-regenerating anion suppressor located upstream of electrospray ionization enabled the simultaneous detection of pyrophosphoester by conductimetry, UV and MS. By HPAEC-ITMS and HPAEC-ITMS2, a single run permitted characterization of reference phosphoantigens and of related structures. Although all compounds were resolved by HPAEC, MS enabled their detection and identification by [M-H]- and fragment ions. Isobaric phosphoantigen analogues were also separated by HPAEC and distinguished by MS2. The relevance of this device was demonstrated for phosphoantigens analysis in human urine and plasma. Furthermore, identification of natural phosphoantigens by automatically generated 2D mass spectra from nano-ESI-ITMS is presented. This last technique permits the simultaneous performance of molecular screening of natural phosphoantigen extracts and their identification.

  8. Generic detection of basic taxoids in wood of European Yew (Taxus baccata) by liquid chromatography-ion trap mass spectrometry.

    Science.gov (United States)

    Kite, Geoffrey C; Rowe, Emily R; Veitch, Nigel C; Turner, Jill E; Dauncey, Elizabeth A

    2013-02-01

    The occurrence of the cardiotoxin taxine (comprising taxine B and several other basic taxoids) in leaves of Taxus baccata L. (European yew) is well known and has led to public concerns about the safety of eating or drinking from utensils crafted from the wood of this poisonous species. The occurrence of basic taxoids in the heartwood of T. baccata had not been examined in detail, although the bark is known to contain 2'β-deacetoxyaustrospicatine. Initial examination of heartwood extracts for 2'β-deacetoxyaustrospicatine by liquid chromatography-mass spectrometry (LC-MS) revealed the presence of this basic taxoid at about 0.0007% dry weight, using a standard isolated from bark. Analyses for taxine B, however, proved negative at the extract concentration analysed. Observing other basic taxoids within the heartwood extracts was facilitated by developing generic LC-MS methods that utilised a fragment arising from the N-containing acyl group of basic taxoids as a reporter ion. Of the various MS strategies available on a hybrid ion trap-orbitrap instrument that allowed observation of this reporter ion, combining all-ion collisions with high resolution ion filtering by the orbitrap was most effective, both in terms of the number of basic taxoids detected and sensitivity. Numerous basic taxoids, in addition to 2'β-deacetoxyaustrospicatine, were revealed by this method in heartwood extracts of T. baccata. Red wine readily extracted the basic taxoids from heartwood while coffee extracted them less efficiently. Contamination with basic taxoids could also be detected in soft cheese that had been spread onto wood. The generic LC-MS method for detecting basic taxoids complements specific methods for detecting taxine B when investigating yew poisoning cases in which the analysis of complex extracts may be required or taxine B has not been detected.

  9. The potential of combining ion trap/MS/MS and TOF/MS for identification of emerging contaminants

    Science.gov (United States)

    Ferrer, I.; Furlong, E.T.; Heine, C.E.; Thurman, E.M.

    2002-01-01

    The use of a method combining ion trap tandem mass spectrometry (MS/MS) and time of flight mass spectrometry (TOF/MS) for identification of emerging contaminates was discussed. The two tools together complemented each other in sensitivity, fragmentation and accurate mass determination. Liquid chromatography/electrospray ionization/ion-trap tandem mass spectrometry (LC/ESI/MS/MS), in positive ion mode of operation, was used to separate and identify specific compounds. Diagnostic fragment ions were obtained for a polyethyleneglycol(PEG) homolog by ion trap MS/MS, and fragments were measured by TOF/MS. It was observed that the combined method gave an exact mass measurement that differed from the calculated mass.

  10. GA and Lyapunov theory-based hybrid adaptive fuzzy controller for non-linear systems

    Science.gov (United States)

    Roy, Ananya; Das Sharma, Kaushik

    2015-02-01

    In this present article, a new hybrid methodology for designing stable adaptive fuzzy logic controllers (AFLCs) for a class of non-linear system is proposed. The proposed design strategy exploits the features of genetic algorithm (GA)-based stochastic evolutionary global search technique and Lyapunov theory-based local adaptation scheme. The objective is to develop a methodology for designing AFLCs with optimised free parameters and guaranteed closed-loop stability. Simultaneously, the proposed method introduces automation in the design process. The stand-alone Lyapunov theory-based design, GA-based design and proposed hybrid GA-Lyapunov design methodologies are implemented for two benchmark non-linear plants in simulation case studies with different reference signals and one experimental case study. The results demonstrate that the hybrid design methodology outperforms the other control strategies on the whole.

  11. High Bandwidth Rotary Fast Tool Servos and a Hybrid Rotary/Linear Electromagnetic Actuator

    Energy Technology Data Exchange (ETDEWEB)

    Montesanti, Richard Clement [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    2005-09-01

    This thesis describes the development of two high bandwidth short-stroke rotary fast tool servos and the hybrid rotary/linear electromagnetic actuator developed for one of them. Design insights, trade-o® methodologies, and analytical tools are developed for precision mechanical systems, power and signal electronic systems, control systems, normal-stress electromagnetic actuators, and the dynamics of the combined systems.

  12. Global hybrids from the semiclassical atom theory satisfying the local density linear response

    CERN Document Server

    Fabiano, E; Cortona, P; Della Sala, F

    2015-01-01

    We propose global hybrid approximations of the exchange-correlation (XC) energy functional which reproduce well the modified fourth-order gradient expansion of the exchange energy in the semiclassical limit of many-electron neutral atoms and recover the full local density approximation (LDA) linear response. These XC functionals represent the hybrid versions of the APBE functional [Phys. Rev. Lett. 106, 186406, (2011)] yet employing an additional correlation functional which uses the localization concept of the correlation energy density to improve the compatibility with the Hartree-Fock exchange as well as the coupling-constant-resolved XC potential energy. Broad energetical and structural testings, including thermochemistry and geometry, transition metal complexes, non-covalent interactions, gold clusters and small gold-molecule interfaces, as well as an analysis of the hybrid parameters, show that our construction is quite robust. In particular, our testing shows that the resulting hybrid, including 20\\% o...

  13. High-throughput walkthrough detection portal for counter terrorism: detection of triacetone triperoxide (TATP) vapor by atmospheric-pressure chemical ionization ion trap mass spectrometry.

    Science.gov (United States)

    Takada, Yasuaki; Nagano, Hisashi; Suzuki, Yasutaka; Sugiyama, Masuyuki; Nakajima, Eri; Hashimoto, Yuichiro; Sakairi, Minoru

    2011-09-15

    With the aim of improving security, a high-throughput portal system for detecting triacetone triperoxide (TATP) vapor emitted from passengers and luggage was developed. The portal system consists of a push-pull air sampler, an atmospheric-pressure chemical ionization (APCI) ion source, and an explosives detector based on mass spectrometry. To improve the sensitivity of the explosives detector, a novel linear ion trap mass spectrometer with wire electrodes (wire-LIT) is installed in the portal system. TATP signals were clearly obtained 2 s after the subject under detection passed through the portal system. Preliminary results on sensitivity and throughput show that the portal system is a useful tool for preventing the use of TATP-based improvised explosive devices by screening persons in places where many people are coming and going.

  14. Fabrication and characterization of semiconductor ion traps for quantum information processing

    Science.gov (United States)

    Stick, Daniel Lynn

    The electromagnetic manipulation of isolated ions has led to many advances in atomic physics, from laser cooling to precision metrology and quantum control. As technical capability in this area has grown, so has interest in building miniature electromagnetic traps for the development of large-scale quantum information processors. This thesis will primarily focus on using microfabrication techniques to build arrays of miniature ion traps, similar to techniques used in fabricating high component density microprocessors. A specific focus will be on research using a gallium arsenide/aluminum gallium arsenide heterostructure as a trap architecture, as well as the recent testing of different ion traps fabricated at outside foundries. The construction and characterization of a conventional ceramic trap capable of shuttling an ion through a junction will also be detailed, and reveal the need for moving towards lithographically fabricated traps. Combined, these serve as a set of proof-of-principle experiments pointing to methods for designing and building large scale arrays of ion traps capable of constituting a quantum information processor. As traps become smaller, electrical potentials on the electrodes have greater influence on the ion. This not only pertains to intentionally applied voltages, but also to deleterious noise sources, such as thermal Johnson noise and the more significant "patch potential" noise, which both cause motional heating of the ion. These problematic noise sources dovetail with my thesis research into trap miniaturization since their effects become more pronounced and impossible to ignore for small trap sizes. Therefore characterizing them and investigating ways to suppress them have become an important component of my research. I will describe an experiment using a pair of movable needle electrodes to measure the ion heating rate corresponding to the harmonic frequency of the trap, the ion-electrode distance, and the electrode temperature. This

  15. An Effective Hybrid Artificial Bee Colony Algorithm for Nonnegative Linear Least Squares Problems

    Directory of Open Access Journals (Sweden)

    Xiangyu Kong

    2014-07-01

    Full Text Available An effective hybrid artificial bee colony algorithm is proposed in this paper for nonnegative linear least squares problems. To further improve the performance of algorithm, orthogonal initialization method is employed to generate the initial swarm. Furthermore, to balance the exploration and exploitation abilities, a new search mechanism is designed. The performance of this algorithm is verified by using 27 benchmark functions and 5 nonnegative linear least squares test problems. And the comparison analyses are given between the proposed algorithm and other swarm intelligence algorithms. Numerical results demonstrate that the proposed algorithm displays a high performance compared with other algorithms for global optimization problems and nonnegative linear least squares problems.

  16. Amplification of infrared multiphoton dissociation efficiency in a quadruple ion trap using IR-active ligands.

    Science.gov (United States)

    Pikulski, Michael; Wilson, Jeffrey J; Aguilar, Apolonio; Brodbelt, Jennifer S

    2006-12-15

    A strategy for increasing the efficiency of infrared multiphoton dissociation (IRMPD) in a quadrupole ion trap (QIT) is described. IR-active ligands (IRALs) are incorporated into noncovalent complexes of the type [M2+(analyte) IRAL]+, where M is a transition metal such as copper or cobalt and IRAL is an auxiliary ligand with an IR-active phosphonate functional group. The complexes are formed via self-assembly in solution directly prior to ESI-MS analysis. We demonstrate this new IRMPD approach for the structural characterization of flavonoids. The fragment ions obtained by IRMPD are similar to those obtained by CAD and allow facile isomer differentiation of flavonoids. Fourier transform infrared absorption attenuated total reflectance (FTIR-ATR) and energy-variable CAD experiments indicate that the high IRMPD efficiencies stem from the very large IR absorptivities of the IR-active ligands.

  17. Optical and magnetic measurements of gyroscopically stabilized graphene nanoplatelets levitated in an ion trap

    Science.gov (United States)

    Nagornykh, Pavel; Coppock, Joyce E.; Murphy, Jacob P. J.; Kane, B. E.

    2017-07-01

    Using optical measurements, we demonstrate that the rotation of micron-scale graphene nanoplatelets levitated in a quadrupole ion trap in high vacuum can be frequency-locked to an applied radiofrequency electric field Erf. Over time, frequency-locking stabilizes the nanoplatelet so that its axis of rotation is normal to the nanoplatelet and perpendicular to Erf. We observe that residual slow dynamics of the direction of the axis of rotation in the plane normal to Erf is determined by an applied magnetic field. We present a simple model that accurately describes our observations. From our data and model, we can infer both a diamagnetic polarizability and a magnetic moment proportional to the frequency of rotation, which we compare to theoretical values. Our results establish that trapping technologies have applications for materials measurements at the nanoscale.

  18. EBIT - Electronic Beam Ion Trap: N Divison experimental physics annual report 1995

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, D. [ed.

    1996-10-01

    The multi-faceted research effort of the EBIT (Electron Beam Ion Trap) program in N-Division of the Physics and Space Technology Department at Lawrence Livermore National Laboratory (LLNL) continues to contribute significant results to the physical sciences from studies with low energy very highly charged heavy ions. The EBIT program attracts a number of collaborators from the US and abroad for the different projects. The collaborations are partly carried out through participating graduate students demonstrating the excellent educational capabilities at the LLNL EBIT facilities. Moreover, participants from Historically Black Colleges and Universities are engaged in the EBIT project. This report describes EBIT work for 1995 in atomic structure measurements and radiative transition probabilities, spectral diagnostics for laboratory and astrophysical plasmas, ion/surface interaction studies, electron-ion interactions studies, retrap and ion collisions, and instrumental development.

  19. Rare-earth neutral metal injection into an electron beam ion trap plasma

    Energy Technology Data Exchange (ETDEWEB)

    Magee, E. W., E-mail: magee1@llnl.gov; Beiersdorfer, P.; Brown, G. V. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Hell, N. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Dr. Remeis-Sternwarte and ECAP, Universität Erlangen-Nürnberg, 96049 Bamberg (Germany)

    2014-11-15

    We have designed and implemented a neutral metal vapor injector on the SuperEBIT high-energy electron beam ion trap at the Lawrence Livermore National Laboratory. A horizontally directed vapor of a europium metal is created using a thermal evaporation technique. The metal vapor is then spatially collimated prior to injection into the trap. The source's form and quantity constraints are significantly reduced making plasmas out of metal with vapor pressures ≤10{sup −7} Torr at ≥1000 °C more obtainable. A long pulsed or constant feed metal vapor injection method adds new flexibility by varying the timing of injection and rate of material being introduced into the trap.

  20. Quantification of Fumaria officinalis isoquinoline alkaloids by nonaqueous capillary electrophoresis-electrospray ion trap mass spectrometry.

    Science.gov (United States)

    Sturm, Sonja; Strasser, Eva-Maria; Stuppner, Hermann

    2006-04-21

    A capillary electrophoresis (CE) method using non-aqueous (NA) separation solutions combined with an ion trap mass spectrometer (MS and MS/MS) as detection device is presented for the separation, identification and quantification of isoquinoline alkaloids from Fumaria officinalis. The best results were obtained with a mixture of acetonitrile-methanol (9:1, v/v) containing 60mM ammonium acetate and 2.2M acetic acid as running electrolyte and an applied voltage of 30 kV. Electrospray MS measurements were performed in the positive ionization mode with isopropanol-water (1:1, v/v) as sheath liquid at a flow rate of 3 microl/min. Alkaloids were detected as [M+H](+)-ions and showed typical fragmentation patterns in MS/MS experiments. The developed assay was used for the quantification of seven isoquinoline alkaloids representing different structural subtypes in Fumariae herba extracts and F. herba containing phytopharmaceuticals.

  1. High-resolution spectroscopy of CH2D+ in a cold 22-pole ion trap.

    Science.gov (United States)

    Gärtner, Sabrina; Krieg, Jürgen; Klemann, André; Asvany, Oskar; Brünken, Sandra; Schlemmer, Stephan

    2013-10-03

    The method of laser-induced reaction (LIR) is used to obtain high-resolution IR spectra of CH2D(+) in collision with n-H2 at a nominal temperature of 14 K. For this purpose, a home-built optical parametric oscillator (OPO), tunable in the range of 2500-4000 cm(-1), has been coupled to a 22-pole ion trap apparatus. In total, 112 lines of the ν1 and ν4 bands have been recorded. A line list is inferred from a careful analysis of the shape of the LIR signal. Line positions have been determined to an accuracy of 1 × 10(-4) cm(-1), allowing for the prediction of pure rotational transitions with MHz accuracy. In addition, an IR-THz double-resonance LIR depletion technique is applied to H2D(+) to demonstrate the feasibility for pure rotational spectroscopy with LIR.

  2. Controlled Formation and Vibrational Characterization of Large Solvated Ionic Clusters in Cryogenic Ion Traps

    Science.gov (United States)

    Garand, Etienne; Marsh, Brett; Voss, Jonathan; Duffy, Erin M.

    2016-06-01

    An experimental approach for the formation of solvated ionic clusters and their vibrational spectroscopy will be presented. This recently developed apparatus combines an electrospray ionization source, two temperature controlled cryogenic ion traps and a time-of-flight infrared photofragmentation spectrometer, to allow for a universal and controlled formation and characterization of solvent clusters around ionic core as well as product of ion-molecule reaction. Recent results on the spectroscopy of such solvated ions, will be presented and discussed. In particular, this talk will present the structural evolution of glycylglycine as a function of stepwise solvation, and show how the presence of just a few water can modify the geometry of this model peptide. I will also present results solvation of ion that do not form hydrogen bond or strongly interactions with the solvent.

  3. Efficient fluorescence collection and ion imaging with the "tack" ion trap

    CERN Document Server

    Shu, G; Kurz, N; Dietrich, M R; Blinov, B B

    2011-01-01

    Trapped, laser-cooled ions produce intense fluorescence. Detecting this fluorescence enables efficient measurement of quantum state of qubits based on trapped atoms. It is desirable to collect a large fraction of the photons to make the detection faster and more reliable. Additionally, efficient fluorescence collection can improve speed and fidelity of remote ion entanglement and quantum gates. Here we show a novel ion trap design that incorporates metallic spherical mirror as the integral part of the trap itself, being its RF electrode. The mirror geometry enables up to 35% solid angle collection of trapped ion fluorescence; we measure a 25% effective solid angle, likely limited by imperfections of the mirror surface. We also study properties of the images of single ions formed by the mirror and apply aberration correction. Owing to the simplicity of its design, this trap structure can be adapted for micro-fabrication and integration into more complex trap architectures.

  4. A rare-earth-magnet ion trap for confining low-Z, bare nuclei

    Science.gov (United States)

    Brewer, Samuel M.; Tan, Joseph N.

    2009-05-01

    Simplifications in the theory for Rydberg states of hydrogenlike ions allow a substantial improvement in the accuracy of predicted levels, which can yield information on the values of fundamental constants and test theory if they can be compared with precision frequency measurements.[1] We consider the trapping of bare nuclei (fully-stripped) to be used in making Rydberg states of one-electron ions with atomic number 1earth permanent magnets, and to model the capture of charge-state-selected ions extracted from an electron beam ion trap (EBIT). An experimental apparatus adapted to the NIST EBIT will also be discussed. Reference: [1] U.D. Jentschura, P.J. Mohr, J.N. Tan, and B.J. Wundt, ``Fundamental constants and tests of theory in Rydberg states of hydrogenlike ions,'' Phys. Rev. Lett. 100, 160404 (2008).

  5. Cascade emission in electron beam ion trap plasma of W$^{25+}$ ion

    CERN Document Server

    Jonauskas, V; Kučas, S; Masys, Š; Kynienė, A; Gaigalas, G; Kisielius, R; Radžiūtė, L; Rynkun, P; Merkelis, G

    2015-01-01

    Spectra of the W$^{25+}$ ion are studied using the collisional-radiative model (CRM) with an ensuing cascade emission. It is determined that the cascade emission boosts intensities only of a few lines in the $10 - 3$ nm range. The cascade emission is responsible for the disappearance of structure of lines at about 6 nm in the electron beam ion trap plasma. Emission band at 4.5 to 5.3 nm is also affected by the cascade emission. The strongest lines in the CRM spectrum correspond to $4d^{9} 4f^{4} \\rightarrow 4f^{3}$ transitions, while $4f^{2} 5d \\rightarrow 4f^{3}$ transitions arise after the cascade emission is taken into account.

  6. High resolution EUV spectroscopy of xenon ions with a compact electron beam ion trap

    Science.gov (United States)

    Ali, Safdar; Nakamura, Nobuyuki

    2017-09-01

    We performed high resolution extreme ultraviolet (EUV) spectroscopy measurements of highly charged xenon ions with a compact electron beam ion trap. The spectra were recorded with a flat-field grazing incidence spectrometer while varying the electron beam energy between 200 and 890 eV. We measured the wavelengths for several lines of Rh-like Xe9+ - Cd-like Xe6+ and Cu-like Xe25+- Se-like Xe20+ in the range of 150-200 Å with an uncertainty of 0.05 Å. Previously, most of these lines have been reported from EBITs with a wavelength uncertainty of 0.2 Å. Additionally, based on the electron beam energy dependence of the observed spectra we tentatively identified three new lines, which were reported as unidentified lines in the previous studies.

  7. Characterization of fluorescence collection optics integrated with a micro-fabricated surface electrode ion trap

    CERN Document Server

    Clark, Craig R; Ellis, A R; Hunker, Jeff; Kemme, Shanalyn A; Maunz, Peter; Tabakov, Boyan; Tigges, Chris; Stick, Daniel L

    2013-01-01

    One of the outstanding challenges for ion trap quantum information processing is to accurately detect the states of many ions in a scalable fashion. In the particular case of surface traps, geometric constraints make imaging perpendicular to the surface appealing for light collection at multiple locations with minimal cross-talk. In this report we describe an experiment integrating Diffractive Optic Elements (DOE's) with surface electrode traps, connected through in-vacuum multi-mode fibers. The square DOE's reported here were all designed with solid angle collection efficiencies of 3.58%; with all losses included a detection efficiency of 0.388% (1.02% excluding the PMT loss) was measured with a single Ca+ ion. The presence of the DOE had minimal effect on the stability of the ion, both in temporal variation of stray electric fields and in motional heating rates.

  8. Linear and Nonlinear Rheology Combined with Dielectric Spectroscopy of Hybrid Polymer Nanocomposites for Semiconductive Applications

    Science.gov (United States)

    Kádár, Roland; Abbasi, Mahdi; Figuli, Roxana; Rigdahl, Mikael; Wilhelm, Manfred

    2017-01-01

    The linear and nonlinear oscillatory shear, extensional and combined rheology-dielectric spectroscopy of hybrid polymer nanocomposites for semiconductive applications were investigated in this study. The main focus was the influence of processing conditions on percolated poly(ethylene-butyl acrylate) (EBA) nanocomposite hybrids containing graphite nanoplatelets (GnP) and carbon black (CB). The rheological response of the samples was interpreted in terms of dispersion properties, filler distortion from processing, filler percolation, as well as the filler orientation and distribution dynamics inside the matrix. Evidence of the influence of dispersion properties was found in linear viscoelastic dynamic frequency sweeps, while the percolation of the nanocomposites was detected in nonlinearities developed in dynamic strain sweeps. Using extensional rheology, hybrid samples with better dispersion properties lead to a more pronounced strain hardening behavior, while samples with a higher volume percentage of fillers caused a drastic reduction in strain hardening. The rheo-dielectric time-dependent response showed that in the case of nanocomposites containing only GnP, the orientation dynamics leads to non-conductive samples. However, in the case of hybrids, the orientation of the GnP could be offset by the dispersing of the CB to bridge the nanoplatelets. The results were interpreted in the framework of a dual PE-BA model, where the fillers would be concentrated mainly in the BA regions. Furthermore, better dispersed hybrids obtained using mixing screws at the expense of filler distortion via extrusion processing history were emphasized through the rheo-dielectric tests. PMID:28336857

  9. Linear and Nonlinear Rheology Combined with Dielectric Spectroscopy of Hybrid Polymer Nanocomposites for Semiconductive Applications.

    Science.gov (United States)

    Kádár, Roland; Abbasi, Mahdi; Figuli, Roxana; Rigdahl, Mikael; Wilhelm, Manfred

    2017-01-24

    The linear and nonlinear oscillatory shear, extensional and combined rheology-dielectric spectroscopy of hybrid polymer nanocomposites for semiconductive applications were investigated in this study. The main focus was the influence of processing conditions on percolated poly(ethylene-butyl acrylate) (EBA) nanocomposite hybrids containing graphite nanoplatelets (GnP) and carbon black (CB). The rheological response of the samples was interpreted in terms of dispersion properties, filler distortion from processing, filler percolation, as well as the filler orientation and distribution dynamics inside the matrix. Evidence of the influence of dispersion properties was found in linear viscoelastic dynamic frequency sweeps, while the percolation of the nanocomposites was detected in nonlinearities developed in dynamic strain sweeps. Using extensional rheology, hybrid samples with better dispersion properties lead to a more pronounced strain hardening behavior, while samples with a higher volume percentage of fillers caused a drastic reduction in strain hardening. The rheo-dielectric time-dependent response showed that in the case of nanocomposites containing only GnP, the orientation dynamics leads to non-conductive samples. However, in the case of hybrids, the orientation of the GnP could be offset by the dispersing of the CB to bridge the nanoplatelets. The results were interpreted in the framework of a dual PE-BA model, where the fillers would be concentrated mainly in the BA regions. Furthermore, better dispersed hybrids obtained using mixing screws at the expense of filler distortion via extrusion processing history were emphasized through the rheo-dielectric tests.

  10. Characterization of the synthesis of N,N-dimethyltryptamine by reductive amination using gas chromatography ion trap mass spectrometry.

    Science.gov (United States)

    Brandt, Simon D; Moore, Sharon A; Freeman, Sally; Kanu, Abu B

    2010-07-01

    The present study established an impurity profile of a synthetic route to the hallucinogenic N,N-dimethyltryptamine (DMT). The synthesis was carried out under reductive amination conditions between tryptamine and aqueous formaldehyde in the presence of acetic acid followed by reduction with sodium cyanoborohydride. Analytical characterization of this synthetic route was carried out by gas chromatography ion trap mass spectrometry using electron- and chemical-ionization modes. Methanol was employed as a liquid CI reagent and the impact of stoichiometric modifications on side-products formation was also investigated. Tryptamine 1, DMT 2, 2-methyltetrahydro-β-carboline (2-Me-THBC, 3), N-methyl-N-cyanomethyltryptamine (MCMT, 4), N-methyltryptamine (NMT, 5), 2-cyanomethyl-tetrahydro-β-carboline (2-CM-THBC, 6) and tetrahydro-β-carboline (THBC, 7) have been detected under a variety of conditions. Replacement of formaldehyde solution with paraformaldehyde resulted in incomplete conversion of the starting material whereas a similar replacement of sodium cyanoborohydride with sodium borohydride almost exclusively produced THBC instead of the expected DMT. Compounds 1 to 7 were quantified and the limits of detection were 28.4, 87.7, 21.5, 23.4, 41.1, 36.6, and 34.9 ng mL(-1), respectively. The limits of quantification for compounds 1 to 7 were 32.4, 88.3, 25.4, 24.6, 41.4, 39.9, and 37.0 µg mL(-1), respectively. Linearity was observed in the range of 20.8-980 µg mL(-1) with correlation coefficients > 0.99. The application holds great promise in the area of forensic chemistry where development of reliable analytical methods for the detection, identification, and quantification of DMT are crucial and also in pharmaceutical analysis where DMT might be prepared for use in human clinical studies. Copyright 2010 John Wiley & Sons, Ltd.

  11. Collisions of FeO(+) with H2 and He in a Cryogenic Ion Trap.

    Science.gov (United States)

    Gerlich, Dieter; Jašík, Juraj; Andris, Erik; Navrátil, Rafael; Roithová, Jana

    2016-11-18

    The nominal temperature range of cryogenic radio-frequency ion traps has recently been extended down to T=2.3 K. Whereas in situ He tagging of mass-selected ions embedded in dense helium buffer gas is becoming common for recording IR spectra through photofragmentation of small and large ions, much less activity is devoted to the field of cold chemistry, which in this contribution means the two orders of magnitude extending from 300 to below 3 K. The importance of this temperature range for understanding the dynamics of bi- and termolecular reactions is illustrated with new results for the time-honored reaction of FeO(+) with H2 obtained with the cryogenic ion trap ISORI in Prague. The rate coefficient for forming Fe(+) +H2 O increases steeply with decreasing temperature. In addition more product channels open up, such as the stabilized reaction-intermediate complexes H2 FeO(+) and Hen -FeO(+) formed by ternary association with He. For the FeOH(+) +H channel only a minor signal is observed. The rate coefficients provide deep insight into lifetimes, bottlenecks, and barriers impeding almost completely the exothermic, but spin-forbidden, reaction at room temperature. For some of the He-tagged ions, IR predissociation spectra are recorded. A breakthrough is obtaining the first spectrum of [(H2 )FeO](+) , synthesized and tagged in situ with He. These results pave the way to study the structures of reaction intermediates stabilized in the gas phase by means of collisions with helium. © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. On the combination of a low energy hydrogen atom beam with a cold multipole ion trap

    Energy Technology Data Exchange (ETDEWEB)

    Borodi, Gheorghe

    2008-12-09

    The first part of the activities of this thesis was to develop a sophisticated ion storage apparatus dedicated to study chemical processes with atomic hydrogen. The integration of a differentially pumped radical beam source into an existing temperature variable 22- pole trapping machine has required major modifications. Since astrophysical questions have been in the center of our interest, the introduction first gives a short overview of astrophysics and -chemistry. The basics of ion trapping in temperature variable rf traps is well-documented in the literature; therefore, the description of the basic instrument (Chapter 2) is kept rather short. Much effort has been put into the development of an intense and stable source for hydrogen atoms the kinetic energy of which can be changed. Chapter 3 describes this module in detail with emphasis on the integration of magnetic hexapoles for guiding the atoms and special treatments of the surfaces for reducing H-H recombination. Due to the unique sensitivity of the rf ion trapping technique, this instrument allows one to study a variety of reactions of astrochemical and fundamental interest. The results of this work are summarized in Chapter 4. Reactions of CO{sub 2}{sup +} with hydrogen atoms and molecules have been established as calibration standard for in situ determination of H and H{sub 2} densities over the full temperature range of the apparatus (10 K-300 K). For the first time, reactions of H- and D-atoms with the ionic hydrocarbons CH{sup +}, CH{sub 2}{sup +}, and CH{sub 4}{sup +} have been studied at temperatures of interstellar space. A very interesting, not yet fully understood collision system is the interaction of protonated methane with H. The outlook presents some ideas, how to improve the new instrument and a few reaction systems are mentioned which may be studied next. (orig.)

  13. Two Hybrid Methods for Solving Two-Dimensional Linear Time-Fractional Partial Differential Equations

    Directory of Open Access Journals (Sweden)

    B. A. Jacobs

    2014-01-01

    Full Text Available A computationally efficient hybridization of the Laplace transform with two spatial discretization techniques is investigated for numerical solutions of time-fractional linear partial differential equations in two space variables. The Chebyshev collocation method is compared with the standard finite difference spatial discretization and the absolute error is obtained for several test problems. Accurate numerical solutions are achieved in the Chebyshev collocation method subject to both Dirichlet and Neumann boundary conditions. The solution obtained by these hybrid methods allows for the evaluation at any point in time without the need for time-marching to a particular point in time.

  14. Non-fragile hybrid guaranteed cost control for a class of uncertain switched linear systems

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    This paper focuses on the problem of non-fragile hybrid guaranteed cost control for a class of uncertain switched linear systems. The controller gain to be designed is assumed to have additive gain variations. Based on multiple-Lyapunov function technique, the design of non-fragile hybrid guaranteed cost controllers is derived to make the corresponding closed-loop system asymptotically stable for all admissible uncertainties. Furthermore, a convex optimization approach with LMIs constraints is introduced to select the optimal non-fragile guaranteed cost controllers. Finally, a simulation example illustrates the effectiveness of the proposed approach.

  15. The Complexity of Monotone Hybrid Logics over Linear Frames and the Natural Numbers

    CERN Document Server

    Göller, Stefan; Mundhenk, Martin; Schneider, Thomas; Thomas, Michael; Weiss, Felix

    2012-01-01

    Hybrid logic with binders is an expressive specification language. Its satisfiability problem is undecidable in general. If frames are restricted to the natural numbers or general linear orders, then satisfiability is known to be decidable, but of non-elementary complexity. In this paper, we consider monotone hybrid logics (i.e., the Boolean connectives are conjunction and disjunction only) over the natural numbers and general linear orders. We show that the satisfiability problem remains non-elementary over linear orders, but its complexity drops to PSPACE-completeness over natural numbers. We categorize the strict fragments arising from different combinations of modal and hybrid operators into NP-complete and tractable, and show that the latter cases are complete for NC1 or LOGSPACE. Interestingly, NP-completeness depends only on the fragment and not on the frame. For the cases above NP, satisfiability over linear orders is harder than over natural numbers, while below NP it is at most as hard. In addition ...

  16. Advanced quadrupole ion trap instrumentation for low level vehicle emissions measurements. CRADA final report for number ORNL93-0238

    Energy Technology Data Exchange (ETDEWEB)

    McLuckey, S.A.; Buchanan, M.V.; Asano, K.G.; Hart, K.J.; Goeringer, D.E. [Oak Ridge National Lab., TN (United States); Dearth, M.A. [Ford Motor Co., Dearborn, MI (United States). Environmental Research Consortium

    1997-09-01

    Quadrupole ion trap mass spectrometry has been evaluated for its potential use in vehicle emissions measurements in vehicle test facilities as an analyzer for the top 15 compounds contributing to smog generation. A variety of ionization methods were explored including ion trap in situ chemical ionization, atmospheric sampling glow discharge ionization, and nitric oxide chemical ionization in a glow discharge ionization source coupled with anion trap mass spectrometer. Emphasis was placed on the determination of hydrocarbons and oxygenated hydrocarbons at parts per million to parts per billion levels. Ion trap in situ water chemical ionization and atmospheric sampling glow discharge ionization were both shown to be amenable to the analysis of arenes, alcohols, aldehydes and, to some degree, alkenes. Atmospheric sampling glow discharge also generated molecular ions of methyl-t-butyl ether (MTBE). Neither of these ionization methods, however, were found to generate diagnostic ions for the alkanes. Nitric oxide chemical ionization, on the other hand, was found to yield diagnostic ions for alkanes, alkenes, arenes, alcohols, aldehydes, and MTBE. The ability to measure a variety of hydrocarbons present at roughly 15 parts per billion at measurement rates of 3 Hz was demonstrated. These results have demonstrated that the ion trap has an excellent combination of sensitivity, specificity, speed, and flexibility with respect to the technical requirements of the top 15 analyzer.

  17. A hybrid analysis method for linear dynamic soil-structure interaction in time and frequency domain

    Institute of Scientific and Technical Information of China (English)

    丁海平; 廖振鹏

    2001-01-01

    A hybrid analysis method in time and frequency domains for linear soil-structure interaction is presented. First, the time domain solution of the system with Rayleigh damping excited by a short time impulse is obtained by the decoupling numerical simulation technique of near-field wave motion. Then, the corresponding frequency domain solution can be got by Fourier transform. According to the relationship between damping value and dynamic re-sponse of a system, the solution of the system with complex damping can be got by Taylor expansion. The hybrid method makes the best of decoupling and explicit algorithm in time domain, and increases the calculation efficien-cy for linear soil-structure interaction analysis.

  18. A linear dispersion relation for the hybrid kinetic-ion/fluid-electron model of plasma physics

    CERN Document Server

    Told, Daniel; Astfalk, Patrick; Jenko, Frank

    2016-01-01

    A dispersion relation for a commonly used hybrid model of plasma physics is developed, which combines fully kinetic ions and a massless-electron fluid description. Although this model and variations of it have been used to describe plasma phenomena for about 40 years, to date there exists no general dispersion relation to describe the linear wave physics contained in the model. Previous efforts along these lines are extended here to retain arbitrary wave propagation angles, temperature anisotropy effects, as well as additional terms in the generalized Ohm's law which determines the electric field. A numerical solver for the dispersion relation is developed, and linear wave physics is benchmarked against solutions of a full Vlasov-Maxwell dispersion relation solver. This work opens the door to a more accurate interpretation of existing and future wave and turbulence simulations using this type of hybrid model.

  19. Screening methods for linear-scaling short-range hybrid calculations on CPU and GPU architectures

    Science.gov (United States)

    Beuerle, Matthias; Kussmann, Jörg; Ochsenfeld, Christian

    2017-04-01

    We present screening schemes that allow for efficient, linear-scaling short-range exchange calculations employing Gaussian basis sets for both CPU and GPU architectures. They are based on the LinK [C. Ochsenfeld et al., J. Chem. Phys. 109, 1663 (1998)] and PreLinK [J. Kussmann and C. Ochsenfeld, J. Chem. Phys. 138, 134114 (2013)] methods, but account for the decay introduced by the attenuated Coulomb operator in short-range hybrid density functionals. Furthermore, we discuss the implementation of short-range electron repulsion integrals on GPUs. The introduction of our screening methods allows for speedups of up to a factor 7.8 as compared to the underlying linear-scaling algorithm, while retaining full numerical control over the accuracy. With the increasing number of short-range hybrid functionals, our new schemes will allow for significant computational savings on CPU and GPU architectures.

  20. An Object Detection Method Using Wavelet Optical Flow and Hybrid Linear-Nonlinear Classifier

    Directory of Open Access Journals (Sweden)

    Pengcheng Han

    2013-01-01

    Full Text Available We propose a new computational intelligence method using wavelet optical flow and hybrid linear-nonlinear classifier for object detection. With the existing optical flow methods, it is difficult to accurately estimate moving objects with diverse speeds. We propose a wavelet-based optical flow method, which uses wavelet decomposition in optical flow motion estimation. The algorithm can accurately detect moving objects with variable speeds in a scene. In addition, we use the hybrid linear-nonlinear classifier (HLNLC to classify moving objects and static background. HLNLC transforms a nonoptimal scalar variable into its likelihood ratio and uses a scalar quantity as the decision variable. This approach is appropriate for the classification of optical flow feature vectors with unequal variance matrices. The experimental results confirm that our proposed object detection method has an improved accuracy and computation efficiency over other state-of-the-art methods.

  1. A Linear Approach for Depth and Colour Camera Calibration Using Hybrid Parameters

    Institute of Scientific and Technical Information of China (English)

    Ke-Li Cheng; Xuan Ju; Ruo-Feng Tong; Min Tang; Jian Chang; Jian-Jun Zhang

    2016-01-01

    Many recent applications of computer graphics and human computer interaction have adopted both colour cameras and depth cameras as input devices. Therefore, an effective calibration of both types of hardware taking different colour and depth inputs is required. Our approach removes the numerical difficulties of using non-linear optimization in previous methods which explicitly resolve camera intrinsics as well as the transformation between depth and colour cameras. A matrix of hybrid parameters is introduced to linearize our optimization. The hybrid parameters offer a transformation from a depth parametric space (depth camera image) to a colour parametric space (colour camera image) by combining the intrinsic parameters of depth camera and a rotation transformation from depth camera to colour camera. Both the rotation transformation and intrinsic parameters can be explicitly calculated from our hybrid parameters with the help of a standard QR factorisation. We test our algorithm with both synthesized data and real-world data where ground-truth depth information is captured by Microsoft Kinect. The experiments show that our approach can provide comparable accuracy of calibration with the state-of-the-art algorithms while taking much less computation time (1/50 of Herrera’s method and 1/10 of Raposo’s method) due to the advantage of using hybrid parameters.

  2. Exciton dynamics and non-linearities in two-dimensional hybrid organic perovskites

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Baki, K.; Boitier, F.; Diab, H.; Lanty, G.; Jemli, K.; Lédée, F.; Deleporte, E.; Lauret, J. S., E-mail: jean-sebastien.lauret@lac.u-psud.fr [Laboratoire Aimé Cotton, CNRS, Univ. Paris-Sud, ENS Cachan, Université Paris-Saclay, 91405 Orsay Cedex (France); Garrot, D. [GEMAC, CNRS, UVSQ, Université Paris-Saclay, 45 avenue des États Unis 78035 Versailles Cedex (France)

    2016-02-14

    Due to their high potentiality for photovoltaic applications or coherent light sources, a renewed interest in hybrid organic perovskites has emerged for few years. When they are arranged in two dimensions, these materials can be considered as hybrid quantum wells. One consequence of the unique structure of 2D hybrid organic perovskites is a huge exciton binding energy that can be tailored through chemical engineering. We present experimental investigations of the exciton non-linearities by means of femtosecond pump-probe spectroscopy. The exciton dynamics is fitted with a bi-exponential decay with a free exciton life-time of ∼100 ps. Moreover, an ultrafast intraband relaxation (<150 fs) is also reported. Finally, the transient modification of the excitonic line is analyzed through the moment analysis and described in terms of reduction of the oscillator strength and linewidth broadening. We show that excitonic non-linearities in 2D hybrid organic perovskites share some behaviours of inorganic semiconductors despite their high exciton binding energy.

  3. Characteristic Analysis and Control of a Hybrid Excitation Linear Eddy Current Brake

    Directory of Open Access Journals (Sweden)

    Baoquan Kou

    2015-07-01

    Full Text Available In this paper, a novel hybrid excitation linear eddy current brake is presented as a braking system for high-speed road and rail vehicles. The presence of the permanent magnets (PMs, whose flux lines in the primary core are oppositely directed with respect to the flux lines by the excitation windings, has the effect of mitigating the saturation of the iron in the teeth of the primary core. This allows the brake to be fed with more intense currents, improving the braking force. First, using the magnetic equivalent circuit method and the layer theory approach, the analytical model of the hybrid excitation linear eddy current brake was developed, which can account for the saturation effects occurring in the iron parts. The saturation effects make the design and control of eddy current brakes more difficult. Second, the relationship between the braking force characteristics and the design parameters were analyzed to provide useful information to the designers of eddy current brakes. Then, the controller of the hybrid excitation linear eddy current brake was designed to control the amplitude of the braking force. Finally, experimental measurements were conducted to verify the validity of the theoretical analysis.

  4. Application of Hybrid Optimization Algorithm in the Synthesis of Linear Antenna Array

    Directory of Open Access Journals (Sweden)

    Ezgi Deniz Ülker

    2014-01-01

    Full Text Available The use of hybrid algorithms for solving real-world optimization problems has become popular since their solution quality can be made better than the algorithms that form them by combining their desirable features. The newly proposed hybrid method which is called Hybrid Differential, Particle, and Harmony (HDPH algorithm is different from the other hybrid forms since it uses all features of merged algorithms in order to perform efficiently for a wide variety of problems. In the proposed algorithm the control parameters are randomized which makes its implementation easy and provides a fast response. This paper describes the application of HDPH algorithm to linear antenna array synthesis. The results obtained with the HDPH algorithm are compared with three merged optimization techniques that are used in HDPH. The comparison shows that the performance of the proposed algorithm is comparatively better in both solution quality and robustness. The proposed hybrid algorithm HDPH can be an efficient candidate for real-time optimization problems since it yields reliable performance at all times when it gets executed.

  5. Linear and Nonlinear Rheology Combined with Dielectric Spectroscopy of Hybrid Polymer Nanocomposites for Semiconductive Applications

    Directory of Open Access Journals (Sweden)

    Roland Kádár

    2017-01-01

    Full Text Available The linear and nonlinear oscillatory shear, extensional and combined rheology-dielectric spectroscopy of hybrid polymer nanocomposites for semiconductive applications were investigated in this study. The main focus was the influence of processing conditions on percolated poly(ethylene-butyl acrylate (EBA nanocomposite hybrids containing graphite nanoplatelets (GnP and carbon black (CB. The rheological response of the samples was interpreted in terms of dispersion properties, filler distortion from processing, filler percolation, as well as the filler orientation and distribution dynamics inside the matrix. Evidence of the influence of dispersion properties was found in linear viscoelastic dynamic frequency sweeps, while the percolation of the nanocomposites was detected in nonlinearities developed in dynamic strain sweeps. Using extensional rheology, hybrid samples with better dispersion properties lead to a more pronounced strain hardening behavior, while samples with a higher volume percentage of fillers caused a drastic reduction in strain hardening. The rheo-dielectric time-dependent response showed that in the case of nanocomposites containing only GnP, the orientation dynamics leads to non-conductive samples. However, in the case of hybrids, the orientation of the GnP could be offset by the dispersing of the CB to bridge the nanoplatelets. The results were interpreted in the framework of a dual PE-BA model, where the fillers would be concentrated mainly in the BA regions. Furthermore, better dispersed hybrids obtained using mixing screws at the expense of filler distortion via extrusion processing history were emphasized through the rheo-dielectric tests.

  6. Surpassing the no-cloning limit with a heralded hybrid linear amplifier for coherent states

    Science.gov (United States)

    Haw, Jing Yan; Zhao, Jie; Dias, Josephine; Assad, Syed M.; Bradshaw, Mark; Blandino, Rémi; Symul, Thomas; Ralph, Timothy C.; Lam, Ping Koy

    2016-10-01

    The no-cloning theorem states that an unknown quantum state cannot be cloned exactly and deterministically due to the linearity of quantum mechanics. Associated with this theorem is the quantitative no-cloning limit that sets an upper bound to the quality of the generated clones. However, this limit can be circumvented by abandoning determinism and using probabilistic methods. Here, we report an experimental demonstration of probabilistic cloning of arbitrary coherent states that clearly surpasses the no-cloning limit. Our scheme is based on a hybrid linear amplifier that combines an ideal deterministic linear amplifier with a heralded measurement-based noiseless amplifier. We demonstrate the production of up to five clones with the fidelity of each clone clearly exceeding the corresponding no-cloning limit. Moreover, since successful cloning events are heralded, our scheme has the potential to be adopted in quantum repeater, teleportation and computing applications.

  7. Characterization of impurities in tylosin using dual liquid chromatography combined with ion trap mass spectrometry.

    Science.gov (United States)

    Chopra, Shruti; Van Schepdael, Ann; Hoogmartens, Jos; Adams, Erwin

    2013-03-15

    Investigation of unknown impurities in a tylosin sample was performed using liquid chromatography coupled to mass spectrometry (LC/MS). Separation was performed according to the recently described LC-UV method of Ashenafi et al. (2011) [14]. This method was reported to have a good selectivity as it was able to separate the four main components of tylosin from the already known and 23 unknown impurities. However, as this method uses a mobile phase with non-volatile constituents, direct characterization of these impurities using LC/MS was not possible. The impurity fractions were therefore first collected and then desalted before sending them to the MS. Identification of the impurities in the tylosin sample was performed with a quadruple ion trap (IT) MS, with an electrospray ionization (ESI) source in the positive ion mode. The structure of the impurities was deduced by comparing their fragmentation pattern with those of the main components of tylosin. As several peaks in the LC-UV method contained multiple compounds, using this method in total 41 new impurities were (partly) characterized. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. The uses of electron beam ion traps in the study of highly charged ions

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, D.

    1994-11-02

    The Electron Beam Ion Trap (EBIT) is a relatively new tool for the study of highly charged ions. Its development has led to a variety of new experimental opportunities; measurements have been performed with EBITs using techniques impossible with conventional ion sources or storage rings. In this paper, I will highlight the various experimental techniques we have developed and the results we have obtained using the EBIT and higher-energy Super-EBIT built at the Lawrence Livermore National Laboratory. The EBIT employs a high-current-density electron beam to trap, ionize, and excite a population of ions. The ions can be studied in situ or extracted from the trap for external experiments. The trapped ions form an ionization-state equilibrium determined by the relative ionization and recombination rates. Ions of several different elements may simultaneously be present in the trap. The ions are nearly at rest, and, for most systems, all in their ground-state configurations. The electron-ion interaction energy has a narrow distribution and can be varied over a wide range. We have used the EBIT devices for the measurement of electron-ion interactions, ion structure, ion-surface interactions, and the behavior of low-density plasmas.

  9. The XRS microcalorimeter spectrometer at the Livermore Electron Beam Ion Trap

    Energy Technology Data Exchange (ETDEWEB)

    Porter, F S; Beiersdorfer, P; Boyce, K; Brown, G V; Chen, H; Gygax, J; Kahn, S M; Kelley, R; Kilbourne, C A; Magee, E; Thorn, D B

    2007-08-22

    NASA's X-ray Spectrometer (XRS) microcalorimeter instrument has been operating at the Electron Beam Ion Trap (EBIT) facility at Lawrence Livermore National Laboratory since July of 2000. The spectrometer is currently undergoing its third major upgrade to become an easy to use, extremely high performance instrument for a broad range of EBIT experiments. The spectrometer itself is broadband, capable of simultaneously operating from 0.1 to 12 keV and has been operated at up to 100 keV by manipulating its operating conditions. The spectral resolution closely follows the spaceflight version of the XRS, beginning at 10 eV FWHM at 6 keV in 2000, upgraded to 5.5 eV in 2003, and will hopefully be {approx}3.8 eV in the Fall of 2007. Here we review the operating principles of this unique instrument, the extraordinary science that has been performed at EBIT over the last 6 years, and prospects for future upgrades. Specifically we discuss upgrades to cover the high-energy band (to at least 100 keV) with a high quantum efficiency detector, and prospects for using a new superconducting detector to reach 0.8 eV resolution at 1 keV, and 2 eV at 6 keV with high counting rates.

  10. Simulations of beta-decay of 6He in an Electrostatic Ion Trap

    CERN Document Server

    Vaintraub, S; Hass, M; Heber, O; Aviv, O; Rappaport, M; Dhal, A; Mardor, I; Wolf, A

    2014-01-01

    Trapped radioactive atoms present exciting opportunities for the study of fundamental interactions and symmetries. For example, detecting beta decay in a trap can probe the minute experimental signal that originates from possible tensor or scalar terms in the weak interaction. Such scalar or tensor terms affect, e.g., the angular correlation between a neutrino and an electron in the beta-decay process, thus probing new physics of beyond-the-standard-model nature. The present system focuses on a novel use of an innovative ion trapping device, the Electrostatic Ion Beam Trap. Such a trap has not been previously considered for Fundamental Interaction studies and exhibits potentially very significant advantages over other schemes. These advantages include improved injection efficiency of the radionuclide under study, an extended field-free region, ion-beam kinematics for better efficiency and ease-of operation and the potential for a much larger solid angle for the electron and recoiling atom counters. The beta-d...

  11. Successive Resonances for Ion Ejection at Arbitrary Frequencies in an Ion Trap

    Science.gov (United States)

    Snyder, Dalton T.; Cooks, R. Graham

    2016-09-01

    The use of successive resonances for ion ejection is demonstrated here as a method of scanning quadrupole ion traps with improvement in both resolution and sensitivity compared with single frequency resonance ejection. The conventional single frequency resonance ejection waveform is replaced with a dual-frequency waveform. The two included frequencies are spaced very closely and their relative amplitudes are adjusted so that the first frequency that ions encounter excites them to higher amplitudes where space charge effects are less prominent, thereby giving faster and more efficient ejection when the ions come into resonance with the second frequency. The method is applicable at any arbitrary frequency, unlike double and triple resonance methods. However, like double and triple resonance ejection, ejection using successive resonances requires the rf and AC waveforms to be phase-locked in order to retain mass accuracy and mass precision. The improved performance is seen in mass spectra acquired by rf amplitude scans (resonance ejection) as well as by secular frequency scans.

  12. Characterization of environmental samples using ion trap-secondary ion mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Groenewold, G.S.; Appelhans, A.D.; Ingram, J.C.

    1998-02-01

    The detection of chemical warfare agent residues on environmental surfaces is an important analytical activity because of the potential for proliferation of these weapons, and for environmental monitoring in areas where they are stored. Historically, one of the most widely used agents has been bis(2-chloroethyl) sulfide, also known as mustard gas and HD. It was initially used in combat in 1917; by the end of the First World War, more than 16% of all casualties were due to chemicals, in most cases mustard. Manufacture of mustard is continuing to this day; consequently, there are ongoing opportunities for exposure. 2-Chloroethyl ethyl sulfide (CEES) is used as a simulant for mustard (HD) in a study to develop secondary ion mass spectrometry (SIMS) for rapid, semi-quantitative detection of mustard on soil. Using SIMS with single stage mass spectrometry, a signature for CEES can be unequivocally observed only at the highest concentrations (0.1 monolayer and above). Selectivity and sensitivity are markedly improved employing multiple-stage mass spectrometry using an ion trap. C{sub 2}H{sub 5}SC{sub 2}H{sub 4}{sup +} from CEES eliminates C{sub 2}H{sub 4} and H{sub 2}S, which are highly diagnostic. CEES was detected at 0.0012 monolayer on soil. A single analysis could be conducted in under 5 minutes.

  13. Rapid determination of nicotine in urine by direct thermal desorption ion trap mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Wise, M.B.; Ilgner, R.H.; Guerin, M.R.

    1990-01-01

    The measurement of nicotine and cotinine in physiological fluids (urine, blood serum, and saliva) is widely used as a means of assessing human exposure to environmental tobacco smoke (ETS). Although numerous analytical methods exist for these measurements, they generally involve extensive sample preparation which increases cost and decreases sample throughput. We report the use of thermal desorption directly into an ion trap mass spectrometer (ITMS) for the rapid determination of nicotine and cotinine in urine. A 1{mu}L aliquot of urine is injected into a specially designed inlet and flash vaporized directly into an ITMS through an open-split capillary restrictor interface. Isobutane chemical ionization is used to generate (M+H){sup +} ions of the analytes and collision induced dissociation is used to generate characteristic fragment ions which are used to confirm their identity. Quantification is achieved by integrating the ion current for the characteristic ions and comparing with an external working curve. Detection limits are approximately 50 pg per analyte and the sample turnaround time is approximately 3 minutes without the need for extensive sample preparation. 12 refs., 5 figs.

  14. The XRS microcalorimeter spectrometer at the Livermore Electron Beam Ion Trap

    Energy Technology Data Exchange (ETDEWEB)

    Porter, F S; Beiersdorfer, P; Boyce, K; Brown, G V; Chen, H; Gygax, J; Kahn, S M; Kelley, R; Kilbourne, C A; Magee, E; Thorn, D B

    2007-08-22

    NASA's X-ray Spectrometer (XRS) microcalorimeter instrument has been operating at the Electron Beam Ion Trap (EBIT) facility at Lawrence Livermore National Laboratory since July of 2000. The spectrometer is currently undergoing its third major upgrade to become an easy to use, extremely high performance instrument for a broad range of EBIT experiments. The spectrometer itself is broadband, capable of simultaneously operating from 0.1 to 12 keV and has been operated at up to 100 keV by manipulating its operating conditions. The spectral resolution closely follows the spaceflight version of the XRS, beginning at 10 eV FWHM at 6 keV in 2000, upgraded to 5.5 eV in 2003, and will hopefully be {approx}3.8 eV in the Fall of 2007. Here we review the operating principles of this unique instrument, the extraordinary science that has been performed at EBIT over the last 6 years, and prospects for future upgrades. Specifically we discuss upgrades to cover the high-energy band (to at least 100 keV) with a high quantum efficiency detector, and prospects for using a new superconducting detector to reach 0.8 eV resolution at 1 keV, and 2 eV at 6 keV with high counting rates.

  15. A dual cryogenic ion trap spectrometer for the formation and characterization of solvated ionic clusters

    Energy Technology Data Exchange (ETDEWEB)

    Marsh, Brett M.; Voss, Jonathan M.; Garand, Etienne, E-mail: egarand@chem.wisc.edu [Department of Chemistry, University of Wisconsin-Madison, 1101 University Avenue, Madison, Wisconsin 53706 (United States)

    2015-11-28

    A new experimental approach is presented in which two separate cryogenic ion traps are used to reproducibly form weakly bound solvent clusters around electrosprayed ions and messenger-tag them for single-photon infrared photodissociation spectroscopy. This approach thus enables the vibrational characterization of ionic clusters comprised of a solvent network around large and non-volatile ions. We demonstrate the capabilities of the instrument by clustering water, methanol, and acetone around a protonated glycylglycine peptide. For water, cluster sizes with greater than twenty solvent molecules around a single ion are readily formed. We further demonstrate that similar water clusters can be formed around ions having a shielded charge center or those that do not readily form hydrogen bonds. Finally, infrared photodissociation spectra of D{sub 2}-tagged GlyGlyH{sup +} ⋅ (H{sub 2}O){sub 1−4} are presented. They display well-resolved spectral features and comparisons with calculations reveal detailed information on the solvation structures of this prototypical peptide.

  16. Highly charged ion research at the Livermore electron beam ion traps

    Energy Technology Data Exchange (ETDEWEB)

    Beiersdorfer, P

    2004-01-04

    Spectroscopy performed with the three Livermore electron beam ion traps is reviewed, which is continuing and complementing the innumerable contributions to atomic physics provided over the years by heavy-ion accelerators. Numerous spectrometers were developed that cover the spectral bands from the visible to the hard x ray region. These enabled exhaustive line surveys useful for x-ray astrophysics and for systematic studies along iso-electronic sequences, such as the 4s-4p, 3s-3p, and 2s-2p transitions in ions of the Cu-I, Na-I, and Li-I sequences useful for studying QED and correlation effects as well as for precise determinations of atomic-nuclear interactions. They also enabled measurements of radiative transition probabilities of very long-lived (milli- and microseconds) and very short-live (femtosecond) levels. Because line excitation processes can be controlled by choice of the electron beam energy, the observed line intensities are used to infer cross sections for electron-impact excitation, dielectronic recombination, resonance excitation, and innershell ionization. These capabilities have recently been expanded to simulate x-ray emission from comets by charge exchange. Specific contributions to basic atomic physics, nuclear physics, and high-temperature diagnostics are illustrated.

  17. Sympathetic cooling of 171 Yb+ qubit ions on a scalable ion trap chip using Yb isotopes

    Science.gov (United States)

    Kwon, Yeong-Dae; Ahn, Jun Sik; Hong, Seokjun; Lee, Minjae; Cheon, Hongjin; Cho, Dongil ``Dan''; Kim, Taehyun

    2016-05-01

    To achieve ion trap based large-scale quantum computing devices, motional states of qubit ions must be regulated against heating from ion transportation or noise on the chip surface while leaving internal states of the ions intact. Sympathetic cooling is a natural solution for this problem, but trapping two different species of ions generally requires two sets of optical devices including separate lasers for each ion type, increasing the complexity and the cost of the setup. We tested Doppler-cooled 174 Yb+ ions to sympathetically cool 171 Yb+ qubit ions. Since these two isotopes have energy levels close to each other, the optical setup can be vastly simplified. We also verified that the tail of non-ideally focused cooling beam and the scattered light from the surface create excited state population in the 171 Yb+ qubit ions, as expected. This leads to occasional spontaneous emission events, which currently limits the coherence time of our qubit to a few seconds. We will also discuss our plans for optimizing the experiment, which may increase the coherence time by one or two orders of magnitude. This work was partially supported by ICT R&D program of MSIP/IITP. [10043464, Development of quantum repeater technology for the application to communication systems].

  18. Development of an intense positron source using a crystal--amorphous hybrid target for linear colliders

    CERN Document Server

    Uesugi, Y; Chehab, R; Dadoun, O; Furukawa, K; Kamitani, T; Kawada, S; Omori, T; Takahashi, T; Umemori, K; Urakawa, U; Satoh, M; Strakhovenko, V; Suwada, T; Variola, A

    2013-01-01

    In a conventional positron source driven by a few GeV electron beam, a high amount of heat is loaded into a positron converter target to generate intense positrons required by linear colliders, and which would eventually damage the converter target. A hybrid target, composed of a single crystal target as a radiator of intense gamma--rays, and an amorphous converter target placed downstream of the crystal, was proposed as a scheme which could overcome the problem.This paper describes the development of an intense positron source with the hybrid target. A series of experiments on positron generation with the hybrid target has been carried out with a 8--GeV electron beam at the KEKB linac. We observed that positron yield from the hybrid target increased when the incident electron beam was aligned to the crystal axis and exceeded the one from the conventional target with the converter target of the same thickness, when its thickness is less than about 2 radiation length. The measurements in the temperature rise o...

  19. Analysis, control and optimal operations in hybrid power systems advanced techniques and applications for linear and nonlinear systems

    CERN Document Server

    Bizon, Nicu; Mahdavi Tabatabaei, Naser

    2014-01-01

    This book explains and analyzes the dynamic performance of linear and nonlinear systems, particularly for Power Systems including Hybrid Power Sources. Offers a detailed description of system stability using state space energy conservation principle, and more.

  20. Can the biogenicity of Europa's surfical sulfur be tested simultaneously with penetrators and ion traps?

    Science.gov (United States)

    Chela-Flores, J.; Bhattacherjee, A. B.; Dudeja, S.; Kumar, N.; Seckbach, J.

    2009-04-01

    We suggest a biogenic interpretation of the sulfur patches on the Europan icy surface. This hypothesis is testable by LAPLACE, or a later mission, in which the instrumentation on board are penetrators, or ion traps, with component selection including miniaturized mass spectrometry. The argument in favor of such instrumentation and component selection is as follows: Extreme environments with microbes can act as models for extraterrestrial life (Seckbach et al., 2008). Suggestions have ranged from Venusian environments (Sagan, 1967, Seckbach and Libby, 1970) to Mars (Grilli Caiola and Billi, 2007). Active photosynthetic microbial communities are found on Antarctica, both in and on ice, in fresh water, in saline lakes and streams and within rocks. In the dry valley lakes of Antarctica close to the McMurdo Base, microbial mats are known to selectively remove a huge quantity of sulfur (Parker et al., 1982). Lake Vostok in Antarctica possesses a perennially thick (3 to 4 km) ice-cover that precludes photosynthesis, thus making this subglacial environment a good model system for determining how a potential Europan biota might emerge, evolve and distribute itself. Jupiter's moon Europa may harbor a subsurface water ocean, which lies beneath an ice layer that might be too thick to allow photosynthesis, just as in Lake Vostok. However, disequilibrium chemistry driven by charged particles from Jupiter's magnetosphere could produce sufficient organic and oxidant molecules for an Europan biosphere (Chyba, 2000). We restrict our attention to microbial mats that could still be thriving in spite of the extreme conditions of radiation on Europa. We are especially concerned with sulfur patches discovered by the Galileo mission. In the near future there are technologies available to settle the question of habitability on Europa, such as penetrators that are currently being developed for preliminary trials nearer to the Earth—the Moon-Lite mission (Smith et al., 2008). If analogies

  1. Determination of gamma-hydroxybutyrate in water and human urine by solid phase microextraction-gas chromatography/quadrupole ion trap spectrometry.

    Science.gov (United States)

    Blair, S; Song, M; Hall, B; Brodbelt, J

    2001-05-01

    A simple method of detection was developed for gamma-hydroxybutyrate (GHB). The method involves the derivatization of GHB using a hexyl-chloroformate procedure in aqueous media (such as water or urine), extraction of the derivatization product directly from the sample using solid-phase microextraction, and subsequent separation and detection with gas chromatography quadrupole ion trap mass spectrometry. The deuterated form of GHB (GHB-D6) is used as an internal standard for quantitation. The method was linear for GHB-spiked pure water samples from 2 to 150 microg/mL GHB with a detection limit of 0.2 microg/mL. Spiked urine samples showed linearity from 5 to 500 microg/mL GHB with a detection limit of 2 microg/mL. The SPME-GC/MS method is applied to actual case samples, and the results are compared to those values obtained using a conventional GC/MS method. Sensitivity and linearity are comparable to those seen using traditional methods of separation, yet the SPME method is superior due to the simplicity, speed of analysis, reduction in solvent waste, and ability to differentiate between GHB and gamma-butyrolactone (GBL).

  2. A LINEAR HYBRID MODEL OF MSE AND BEM FOR FLOATING STRUCTURES IN COASTAL ZONES

    Institute of Scientific and Technical Information of China (English)

    ZHANG Jun; MIAO Guo-ping

    2006-01-01

    A linear hybrid model of Mild Slope Equation (MSE) and Boundary Element Method (BEM) is developed to study the wave propagation around floating structures in coastal zones. Both the wave refraction under the influence of topography and the wave diffraction by floating structures are considered. Hence, the model provides wave properties around the coastal floating structures of arbitrary shape but also the wave forces on and the hydrodynamic characteristics of the structures. Different approaches are compared to demonstrate the validity of the present hybrid model. Several numerical tests are carried out for the cases of pontoons under different circumstances. The results show that the influence of topography on the hydrodynamic characteristics of floating structures in coastal regions is important and must not be ignored in the most wave period range with practical interests.

  3. Coherent manipulation of a 40Ca+ spin qubit in a micro ion trap

    DEFF Research Database (Denmark)

    Poschinger, U.G.; Huber, G.; Ziesel, F.;

    2009-01-01

    We demonstrate the implementation of a spin qubit with a single 40Ca+ ion in a micro ion trap. The qubit is encoded in the Zeeman ground state levels mJ = +1/2 and mJ = -1/2 of the S1/2 state of the ion. We show sideband cooling close to the vibrational ground state and demonstrate the initializa......We demonstrate the implementation of a spin qubit with a single 40Ca+ ion in a micro ion trap. The qubit is encoded in the Zeeman ground state levels mJ = +1/2 and mJ = -1/2 of the S1/2 state of the ion. We show sideband cooling close to the vibrational ground state and demonstrate...... to extract the phonon number distribution. The dynamics of this distribution is analysed to deduce the trap-induced heating rate of 0.3(1) phonons ms-1....

  4. Design and property analysis of a hybrid linear actuator based on shape memory alloy

    Science.gov (United States)

    Zhang, Xiaoguang; Hu, Jinhong; Mao, Shixin; Dong, Erbao; Yang, Jie

    2014-12-01

    This paper introduces two methods for solving two bottlelike problems regarding the shape memory alloy (SMA) application as actuators. These methods are ‘rotating output,’ which aims to solve the problem of the low working frequency caused by the demand for cool time, and ‘accumulated shifting,’ which solves the problem of difficult-to-obtain output displacements in a large scale. We also introduce a hybrid linear actuator that applies the two methods and achieves both a strong force and an accurate large output displacement while working at a high frequency based on the SMA wires and DC motors. A prototype of this actuator was fabricated and tested to verify the two methods. This hybrid actuator system dynamic model, which was composed of the constitutive model of the SMA, the electrical and heat transfer behavior of the SMA wires and the dynamics of the linear actuation system, was established and discussed. Our study aims to illuminate the application of an SMA in actuators with the proposed methods with regard to its two main problems. An actuator with a high power-weight ratio and the capability to work at a high frequency, as well as accurate linear step displacements in a large scale, is also presented.

  5. Hybrid state-space self-tuning control of uncertain linear systems

    Science.gov (United States)

    Shieh, L. S.; Wang, Y. J.; Sunkel, J. W.

    1993-01-01

    The paper presents a hybrid state-space self-tuner using a new dual-rate sampling scheme for digital adaptive control of continuous-time uncertain linear systems. A state-space-based recursive least-squares algorithm, together with a variable forgetting factor, is used for direct estimations of both the equivalent discrete-time uncertain linear system parameters and the associated discrete-time state of a continuous-time uncertain linear system from the sampled input and output data. An analogue optimal regional pole-placement design method is used for designing an optimal observer-based analogue controller. A suboptimal observer-based digital controller is then designed from the designed analogue controller using digital redesign technique. To enhance the robustness of parameter identification and state estimation algorithms, a dynamic bound for a class of uncertain bilinear parameters and a fast-rate digital controller are developed at each fast-sampling period. Also, to accommodate computation loads and computation delay for developing the advanced hybrid self-tuner, the designed analogue controller and observer gains are both updated at each slow-sampling period. This control technique has been successfully applied to benchmark control problems.

  6. Analysis of lightweight gases by quadrupole ion trap mass spectrometry for the safety of the American Space Shuttle program

    Science.gov (United States)

    Ottens, Andrew Keith

    The quadrupole ion trap mass spectrometer (QITMS) was patented nearly 50 years ago, when it was proposed for trace analysis of lightweight gas mixtures. Though a commercial success, QITMS has been used with analytes of ever-increasing size. We evaluated QITMS for quantifying lightweight gas mixtures with the performance compared to other mass analyzer technologies. The National Aeronautics and Space Administration (NASA) uses mass spectrometers to monitor the amount of hydrogen, helium, oxygen, and argon in the nitrogen-purged Space Shuttle. The explosive hazard of the cryogenic hydrogen and oxygen used to propel the Space Shuttle makes leak detection imperative. The two present-day leak detectors are remotely located because of their large size and sensitivity to vibration. Analysis is delayed by up to 45 s, and only two samples can be monitored simultaneously. In 2000, NASA initiated the Advanced Hazardous Gas Detection project to develop a compact, rugged, and fast mass spectrometer to be placed in multiple locations next to the Space Shuttle to provide real-time analysis with increased redundancy. The QITMS instrumentation was modified specifically for this application. The RF drive frequency was increased to 2.5 MHz to adequately trap lightweight hydrogen and helium ions. Internal ionization was preferred for use without a collision gas, along with an open source configuration that provided rapid sample replacement. The modern electronics incorporated were controlled by customized software. Analytes were found to react rapidly with abundant background gases. The QITMS operating conditions were optimized to minimize negative effects of ion-molecule reactions while maximizing analytical performance. A custom segmented scan function was developed with a total scan time of 14 ms, averaging 70 scans per data point at the required 1 Hz update rate. The QITMS met requirements for detection limits, accuracy, precision, response time, and recovery time. The linear

  7. Infrared atmospheric pressure MALDI ion trap mass spectrometry of frozen samples using a Peltier-cooled sample stage.

    Science.gov (United States)

    Von Seggern, Christopher E; Gardner, Ben D; Cotter, Robert J

    2004-10-01

    Infrared atmospheric pressure matrix-assisted laser desorption/ionization on an ion trap mass spectrometer is used to analyze frozen samples generated using a Peltier-cooled sample stage. This allows for the analysis of samples in water without the addition of matrix, in near-native conditions, and with minimal loss of water due to evaporation. Analysis of frozen samples is extended to study peptides, carbohydrates, and glycolipids.

  8. Real-Time Quantitative Analysis of H2, He, O2, and Ar by Quadrupole Ion Trap Mass Spectrometry

    Science.gov (United States)

    Ottens, Andrew K.; Harrison, W. W.; Griffin, Timothy P.; Helms, William R.; Voska, N. (Technical Monitor)

    2002-01-01

    The use of a quadrupole ion trap mass spectrometer for quantitative analysis of hydrogen and helium as well as other permanent gases is demonstrated. The customized instrument utilizes the mass selective instability mode of mass analysis as with commercial instruments; however, this instrument operates at a greater RF trapping frequency and without a buffer gas. With these differences, a useable mass range from 2 to over 50 Da is achieved, as required by NASA for monitoring the Space Shuttle during a launch countdown. The performance of the ion trap is evaluated using part-per-million concentrations of hydrogen, helium, oxygen and argon mixed into a nitrogen gas stream. Relative accuracy and precision when quantitating the four analytes were better than the NASA-required minimum of 10% error and 5% deviation, respectively. Limits of detection were below the NASA requirement of 25-ppm hydrogen and 100-ppm helium; those for oxygen and argon were slightly higher than the requirement. The instrument provided adequate performance at fast data recording rates, demonstrating the utility of an ion trap mass spectrometer as a real-time quantitative monitoring device for permanent gas analysis.

  9. A hybrid-stress solid-shell element for non-linear analysis of piezoelectric structures

    Institute of Scientific and Technical Information of China (English)

    SZE; K; Y

    2009-01-01

    This paper presents eight-node solid-shell elements for geometric non-linear analyze of piezoelectric structures. To subdue shear, trapezoidal and thickness locking, the assumed natural strain method and an ad hoc modified generalized laminate stiffness matrix are employed. With the generalized stresses arising from the modified generalized laminate stiffness matrix assumed to be independent from the ones obtained from the displacement, an extended Hellinger-Reissner functional can be derived. By choosing the assumed generalized stresses similar to the assumed stresses of a previous solid ele- ment, a hybrid-stress solid-shell element is formulated. The presented finite shell element is able to model arbitrary curved shell structures. Non-linear numerical examples demonstrate the ability of the proposed model to analyze nonlinear piezoelectric devices.

  10. Extraction of linear anisotropic parameters using optical coherence tomography and hybrid Mueller matrix formalism.

    Science.gov (United States)

    Liao, Chia-Chi; Lo, Yu-Lung

    2015-04-20

    A method is proposed for extracting the linear birefringence (LB) and linear dichroism (LD) properties of an anisotropic optical sample using reflection-mode optical coherence tomography (OCT) and a hybrid Mueller matrix formalism. To ensure the accuracy of the extracted parameter values, a method is proposed for calibrating and compensating the polarization distortion effect induced by the beam splitters in the OCT system using a composite quarter-waveplate / half-waveplate / quarter-waveplate structure. The validity of the proposed method is confirmed by extracting the LB and LD properties of a quarter-wave plate and a defective polarizer. To the best of the authors' knowledge, the method proposed in this study represents the first reported attempt to utilize an inverse Mueller matrix formalism and a reflection-mode OCT structure to extract the LB and LD parameters of optically anisotropic samples.

  11. EBIT (Electron Beam Ion Trap), N-Division Experimental Physics. Annual report, 1994

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, D. [ed.

    1995-10-01

    The experimental groups in the Electron Beam Ion Trap (EBIT) program continue to perform front-line research with trapped and extracted highly charged ions (HCI) in the areas of ion/surface interactions, atomic spectroscopy, electron-ion interaction and structure measurements, highly charged ion confinement, and EBIT development studies. The ion surface/interaction studies which were initiated five years ago have reached a stage where they an carry out routine investigations, as well as produce breakthrough results towards the development of novel nanotechnology. At EBIT and SuperEBIT studies of the x-ray emission from trapped ions continue to produce significant atomic structure data with high precision for few electron systems of high-Z ions. Furthermore, diagnostics development for magnetic and laser fusion, supporting research for the x-ray laser and weapons programs, and laboratory astrophysics experiments in support of NASA`s astrophysics program are a continuing effort. The two-electron contributions to the binding energy of helium like ions were measured for the first time. The results are significant because their precision is an order of magnitude better than those of competing measurements at accelerators, and the novel technique isolates the energy corrections that are the most interesting. The RETRAP project which was initiated three years ago has reached a stage where trapping, confining and electronic cooling of HCI ions up to Th{sup 80+} can be performed routinely. Measurements of the rates and cross sections for electron transfer from H{sub 2} performed to determine the lifetime of HCI up to Xe{sup q+} and Th{sup q+} (35 {le} q {le} 80) have been studied at mean energies estimated to be {approximately} 5 q eV. This combination of heavy ions with very high charges and very low energies is rare in nature, but may be encountered in planned fusion energy demonstration devices, in highly charged ion sources, or in certain astrophysical events.

  12. Screening of new huprines--inhibitors of acetylcholinesterases by electrospray ionization ion trap mass spectrometry.

    Science.gov (United States)

    Ziemianin, Anna; Ronco, Cyril; Dolé, Romain; Jean, Ludovic; Renard, Pierre-Yves; Lange, Catherine M

    2012-11-01

    Acetylcholinesterase inhibitors (AChEI) are one of the drugs families validated for clinical use in the treatment of Alzheimer's disease (AD). For this reason, finding new more potent and more selective AChEIs is always of interest. Since 1961, the inhibitory activity of AChEI is evaluated through the Ellman's method. Herein, we reported a MS-based evaluation of potential new AChEI with the determination of their inhibitory activity (IC(50) and K(I)). Compared to the Ellman's method, that uses the substrate analog acetylthiocholine, the electrospray ionization ion trap mass spectrometry (ESI-IT-MS) consists in monitoring the conversion ratio of a low concentration of the natural substrate - acetylcholine to choline. We present here the inhibition activity of huprine X and six of its derivates (bearing different functional groups at position 9) towards the recombinant human (rhAChE) and Electrophorus electricus acetylcholinesterase (EelAChE). Mechanisms of action of selected inhibitors were evaluated by means of Lineweaver-Burk plot analysis. The Michaelis-Menten constants (K(M)), inhibitory constants (K(I)) were examined as well as the IC(50) to allow classifying a series of huprine derivatives by inhibition potency by a comparison with a reference (huprine X). Our results demonstrate that these drugs are very potent AChE inhibitors, especially (±)-huprine 6 with an inhibitory activity on recombinant human AChE (rhAChE) in the picomolar range. This study reveals the interest of huprine compounds in the treatment of AD. Copyright © 2012. Published by Elsevier B.V.

  13. Proton affinity determinations using the kinetic method in an ion trap mass spectrometer

    Science.gov (United States)

    Nourse, Bobette D.; Graham Cooks, R.

    1991-05-01

    Proton affinities for various compounds have been estimated using a quadrupole ion trap by generating and mass-selecting proton-bound dimers and measuring their dissociation kinetics (A-H+ -B --> AH+ + B and/or BH+ + A). From the relative abundances of the fragment ions ([BH+] and [AH+]), which are related to their relative proton affinities by ln ([AH+]/[BH+]) = [Delta]PA/RT, it is shown that the proton affinities of the alicyclic carboxylic acids decrease in the order: cyclohexane- > cyclopropane- > cyclopentane- > cyclobutanecarboxylic acid. Proton affinity values for these species, measured from their proton-bound dimers with specific ketones, esters and carboxylic acids of known PA, are determined to be 198.3 ± 0.2 kcal mol-1, 198.0 ± 0.2 kcal mol-1, 197.8 ± 0.2 kcal mol-1 and 197.0 ± 0.2 kcal mol-1, respectively. The major contribution to the estimated uncertainties in these values results from the uncertainties in literature proton affinity values for the reference compounds. Proton affinity differences of meta and para deuterated benzoic acid proton-bound to benzoic acid (kH/kD = 1.0 ± 0.1 and 0.9 ± 0.1, respectively), for acetophenone proton-bound to deuterated-acetophenone (C6H5C(O)CD3) (kH/kD = 0.7 ± 0.1) and for 2-pentanone proton-bound to deuterated 2-pentanone (CH3CH2CH2C(O)CH3) (kH/kD = 2.1 ± 0.2). These results, as well as those for the carboxylic acids and benzoic acids given above, are accounted for in terms of stabilizing electronic effects in the protonated molecules.

  14. Characterization of Ni(II) complexes of Schiff bases of amino acids and (S)-N-(2-benzoylphenyl)-1-benzylpyrrolidine-2-carboxamide using ion trap and QqTOF electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Jirásko, Robert; Holcapek, Michal; Kolárová, Lenka; Nádvorník, Milan; Popkov, Alexander

    2008-09-01

    This work demonstrates the application of electrospray ionization mass spectrometry (ESI-MS) using two different mass analyzers, ion trap and hybrid quadrupole time-of-flight (QqTOF) mass analyzer, for the structural characterization of Ni(II) complexes of Schiff bases of (S)-N-(2-benzoylphenyl)-1-benzylpyrrolidine-2-carboxamide with different amino acids. ESI enables the determination of molecular weight on the basis of rather simple positive-ion ESI mass spectra containing only protonated molecules and adducts with sodium or potassium ions. Fragmentation patterns are characterized by tandem mass spectrometric experiments, where both tandem mass analyzers provide complementary information. QqTOF data are used for the determination of elemental composition of individual ions due to mass accuracies always better than 3 ppm with the external calibration, while multistage tandem mass spectra obtained by the ion trap are suitable for studying the fragmentation paths. The novel aspect of our approach is the combination of mass accuracies and relative abundances of all isotopic peaks in isotopic clusters providing more powerful data for the structural characterization of organometallic compounds containing polyisotopic elements. The benefit of relative and absolute mean mass accuracies is demonstrated on the example of studied Ni(II) complexes.

  15. State estimation of stochastic non-linear hybrid dynamic system using an interacting multiple model algorithm.

    Science.gov (United States)

    Elenchezhiyan, M; Prakash, J

    2015-09-01

    In this work, state estimation schemes for non-linear hybrid dynamic systems subjected to stochastic state disturbances and random errors in measurements using interacting multiple-model (IMM) algorithms are formulated. In order to compute both discrete modes and continuous state estimates of a hybrid dynamic system either an IMM extended Kalman filter (IMM-EKF) or an IMM based derivative-free Kalman filters is proposed in this study. The efficacy of the proposed IMM based state estimation schemes is demonstrated by conducting Monte-Carlo simulation studies on the two-tank hybrid system and switched non-isothermal continuous stirred tank reactor system. Extensive simulation studies reveal that the proposed IMM based state estimation schemes are able to generate fairly accurate continuous state estimates and discrete modes. In the presence and absence of sensor bias, the simulation studies reveal that the proposed IMM unscented Kalman filter (IMM-UKF) based simultaneous state and parameter estimation scheme outperforms multiple-model UKF (MM-UKF) based simultaneous state and parameter estimation scheme.

  16. Lifetime of the 1s2s 3S1 metastable level in He-like S14+ measured with an electron beam ion trap

    Energy Technology Data Exchange (ETDEWEB)

    L?pez-Urrutia, J C; Beiersdorfer, P; Widmann, K

    2006-03-16

    A precision measurement of the lifetime of the lowest exited level of the He-like S{sup 14+} ion carried out at the Livermore EBIT-II electron beam ion trap yielded a value of (703 {+-} 4) ns. Our method extends the range of lifetime measurements accessible with electron beam ion traps into the nanosecond region and improves the accuracy of currently available data for this level by an order of magnitude.

  17. A Neural Network Based Hybrid Mixture Model to Extract Information from Non-linear Mixed Pixels

    Directory of Open Access Journals (Sweden)

    Uttam Kumar

    2012-09-01

    Full Text Available Signals acquired by sensors in the real world are non-linear combinations, requiring non-linear mixture models to describe the resultant mixture spectra for the endmember’s (pure pixel’s distribution. This communication discusses inferring class fraction through a novel hybrid mixture model (HMM. HMM is a three-step process, where the endmembers are first derived from the images themselves using the N-FINDR algorithm. These endmembers are used by the linear mixture model (LMM in the second step that provides an abundance estimation in a linear fashion. Finally, the abundance values along with the training samples representing the actual ground proportions are fed into neural network based multi-layer perceptron (MLP architecture as input to train the neurons. The neural output further refines the abundance estimates to account for the non-linear nature of the mixing classes of interest. HMM is first implemented and validated on simulated hyper spectral data of 200 bands and subsequently on real time MODIS data with a spatial resolution of 250 m. The results on computer simulated data show that the method gives acceptable results for unmixing pixels with an overall RMSE of 0.0089 ± 0.0022 with LMM and 0.0030 ± 0.0001 with the HMM when compared to actual class proportions. The unmixed MODIS images showed overall RMSE with HMM as 0.0191 ± 0.022 as compared to the LMM output considered alone that had an overall RMSE of 0.2005 ± 0.41, indicating that individual class abundances obtained from HMM are very close to the real observations.

  18. An atmospheric pressure chemical ionization-ion-trap mass spectrometer for the on-line analysis of volatile compounds in foods: a tool for linking aroma release to aroma perception.

    Science.gov (United States)

    Le Quéré, Jean-Luc; Gierczynski, Isabelle; Sémon, Etienne

    2014-09-01

    An atmospheric pressure chemical ionization ion-trap mass spectrometer was set up for the on-line analysis of aroma compounds. This instrument, which has been successfully employed for some years in several in vitro and in vivo flavour release studies, is described for the first time in detail. The ion source was fashioned from polyether ether ketone and operated at ambient pressure and temperature making use of a discharge corona pin facing coaxially the capillary ion entrance of the ion-trap mass spectrometer. Linear dynamic ranges (LDR), limits of detection (LOD) and other analytical characteristics have been re-evaluated. LDRs and LODs have been found fully compatible with the concentrations of aroma compounds commonly found in foods. Thus, detection limits have been found in the low ppt range for common flavouring aroma compounds (for example 5.3 ppt (0.82 ppbV) for ethyl hexanoate and 4.8 ppt (1.0 ppbV) for 2,5-dimethylpyrazine). This makes the instrument applicable for in vitro and in vivo aroma release investigations. The use of dynamic sensory techniques such as the temporal dominance of sensations (TDS) method conducted simultaneously with in vivo aroma release measurements allowed to get some new insights in the link between flavour release and flavour perception.

  19. HPLC/ESI-quadrupole ion trap mass spectrometry for characterization and direct quantification of amphoteric and nonionic surfactants in aqueous samples

    Science.gov (United States)

    Levine, Lanfang H.; Garland, Jay L.; Johnson, Jodie V.

    2002-01-01

    An amphoteric (cocamidopropylbetaine, CAPB) and a nonionic (alcohol polyethoxylate, AE) surfactant were characterized by electrospray ionization quadrupole ion trap mass spectrometry (ESI-MS) as to their homologue distribution and ionization/fragmentation chemistry. Quantitative methods involving reversed-phase gradient HPLC and (+)ESI-MSn were developed to directly determine these surfactants in hydroponic plant growth medium that received simulated graywater. The predominant homologues, 12 C alkyl CAPB and 9 EO AE, were monitored to represent the total amount of the respective surfactants. The methods demonstrated dynamic linear ranges of 0.5-250 ng (r2 > 0.996) for CAPB and 8-560 ng (r2 > 0.998) for AE homologue mixture, corresponding to minimum quantification limits of 25 ppb CAPB and 0.4 ppm AE with 20-microL injections. This translated into an even lower limit for individual components due to the polydispersive nature of the surfactants. The procedure was successfully employed for the assessment of CAPB and AE biodegradation in a hydroponic plant growth system used as a graywater bioreactor.

  20. Validation of a new liquid chromatography- tandem mass spectrometry ion-trap technique for the simultaneous determination of thirteen anticoagulant rodenticides, drugs, or natural products.

    Science.gov (United States)

    Fourel, Isabelle; Hugnet, Christophe; Goy-Thollot, Isabelle; Berny, Philippe

    2010-03-01

    The purpose of this study was to develop and validate a liquid chromatography-tandem mass spectrometry method for the identification and quantification of anticoagulant (anti-vitamin K or AVK) compounds, including rodenticides, drugs, and natural products because no published method could be found. The proposed method is based on ion-trap technology with electrospray ionization (ESI) and multiple reaction monitoring (MRM) technique. Each AVK is identified by means of its retention time, precursor ion, and two product ions. Plasma samples are extracted by liquid-liquid partition on Toxi-tube B((R)). The method was validated on dog plasma and gave good results in terms of specificity, linearity, and percent recovery for the 14 AVK tested (warfarin, acenocoumarol, bromadiolone, brodifacoum, chlorophacinone, coumatetralyl, dicoumarol, difenacoum, difethialone, flocoumafen, fluindione, phenindione, and tioclomarol). The limits of detection ranged from 5 to 25 ng/mL. Intraday repeatability was good, but interday repeatability was more variable though still sufficient for our diagnostic purposes. The technique was successfully applied in a series of clinical investigations to demonstrate its applicability in various animal species and gave very high sensitivity and specificity results.

  1. High performance liquid chromatography/ion-trap mass spectrometry for separation and simultaneous determination of ethynylestradiol, gestodene, levonorgestrel, cyproterone acetate and desogestrel.

    Science.gov (United States)

    Matejícek, David; Kubán, Vlastimil

    2007-04-11

    A fast and highly sensitive high performance liquid chromatographic/ion-trap mass spectrometric method (LC/MS) has been developed for simultaneous determination of ethynylestradiol (EE2), gestodene (GES), levonorgestrel (LNG), cyproterone acetate (CPA) and desogestrel (DES). Among three types of sorbents tested (C8, C18 and phenyl) from two suppliers, the best separation was achieved on reverse phase Zorbax SB-Phenyl column using aqueous methanol as a mobile phase. A linear gradient profile from 70 up to 100% (v/v) in 7th min, kept constant at 100% up to 10th min and followed by a negative gradient to 70% of methanol up to 12th min was used for elution. Applicability of electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) and influence of the mobile phase composition, its flow rate, capillary/vaporizer temperature of API source and in-source fragmentor voltage ionization are discussed. The on-column limits of quantification (10S/N) were 300 pg of EE2, 14 pg of GES and LNG, 4 pg of CPA and 960 pg of DES per injection (1 microL) using APCI with data collection in selected ion monitoring (SIM) mode. The analytical performance of the method was evaluated using the determination of EE2, GES, LNG, CPA and DES in contraceptives and river water samples.

  2. [Determination of ten basic dyes in meat products by ultra fast liquid chromatography-ion trap time of flight mass spectrometry].

    Science.gov (United States)

    Zhang, Donglei; Wang, Lina; Chen, Xiaozhen; Wang, Jin; Cao, Hui; Huang, Liying

    2012-08-01

    A method was developed for the simultaneous determination of 10 basic dyes in meat products using ultra fast liquid chromatography-ion trap time of flight mass spectrometry (LC-IT-TOF-MS). The target analytes were separated at a flow rate of 0.2 mL/min on a Waters Acquity UPLC BEH C18 (100 mm x 2.1 mm, 1.7 microm) column with a gradient elution. The mobile phase was 5 mmol/L ammonium acetate-acetonitrile (containing 0.1% (v/v) formic acid). The identification and quantification were achieved in positive ion mode with electro spray ionization source. The samples were extracted with a simple procedure using acetonitrile and cleaned up by weak cation exchange (Oasis WCX) solid phase extraction column. Ten basic dyes were determined by LC-IT-TOF-MS, and quantified by external standard method. The developed method showed a good linearity over the wide range of 1.0 - 100.0 microg/L, and the relative standard deviations (n = 7) were less than 8.54%. The average recoveries of the ten basic dyes at three levels (2, 10 and 25 microg/kg) were ranged from 65.39% to 119.18%. Therefore, this method, owing to its simplicity, rapidity and high sensitivity, has a good applicability to the simultaneous determination of dye residues in meat products.

  3. HPLC/ESI-quadrupole ion trap mass spectrometry for characterization and direct quantification of amphoteric and nonionic surfactants in aqueous samples

    Science.gov (United States)

    Levine, Lanfang H.; Garland, Jay L.; Johnson, Jodie V.

    2002-01-01

    An amphoteric (cocamidopropylbetaine, CAPB) and a nonionic (alcohol polyethoxylate, AE) surfactant were characterized by electrospray ionization quadrupole ion trap mass spectrometry (ESI-MS) as to their homologue distribution and ionization/fragmentation chemistry. Quantitative methods involving reversed-phase gradient HPLC and (+)ESI-MSn were developed to directly determine these surfactants in hydroponic plant growth medium that received simulated graywater. The predominant homologues, 12 C alkyl CAPB and 9 EO AE, were monitored to represent the total amount of the respective surfactants. The methods demonstrated dynamic linear ranges of 0.5-250 ng (r2 > 0.996) for CAPB and 8-560 ng (r2 > 0.998) for AE homologue mixture, corresponding to minimum quantification limits of 25 ppb CAPB and 0.4 ppm AE with 20-microL injections. This translated into an even lower limit for individual components due to the polydispersive nature of the surfactants. The procedure was successfully employed for the assessment of CAPB and AE biodegradation in a hydroponic plant growth system used as a graywater bioreactor.

  4. Charge state dependent fragmentation of gaseous [alpha]-synuclein cations via ion trap and beam-type collisional activation

    Science.gov (United States)

    Chanthamontri, Chamnongsak; Liu, Jian; McLuckey, Scott A.

    2009-06-01

    Ions derived from nano-electrospray ionization (nano-ESI) of [alpha]-synuclein, a 14.5 kDa, 140 amino acid residue protein that is a major component of the Lewy bodies associated with Parkinson's disease, have been subjected to ion trap and beam-type collisional activation. The former samples products from fragmentation at rates generally lower than 100 s-1 whereas the latter samples products from fragmentation at rates generally greater than 103 s-1. A wide range of protein charge states spanning from as high as [M+17H]17+ to as low as [M+4H]4+ have been formed either directly from nano-ESI or via ion/ion proton transfer reactions involving the initially formed protein cations and have been subjected to both forms of collision-induced dissociation (CID). The extent of sequence information (i.e., number of distinct amide bond cleavages) available from either CID method was found to be highly sensitive to protein precursor ion charge state. Furthermore, the relative contributions of the various competing dissociation channels were also dependent upon precursor ion charge state. The qualitative trends in the changes in extent of amide bond cleavages and identities of bonds cleaved with precursor ion charge state were similar for two forms of CID. However, for every charge state examined, roughly twice the primary sequence information resulted from beam-type CID relative to ion trap CID. For example, evidence for cleavage of 86% of the protein amide bonds was observed for the [M+9H]9+ precursor ion using beam-type CID whereas 41% of the bonds were cleaved for the same precursor ion using ion trap CID. The higher energies required to drive fragmentation reactions at rates necessary to observe products in the beam experiment access more of the structurally informative fragmentation channels, which has important implications for whole protein tandem mass spectrometry.

  5. A tubular hybrid Halbach/axially-magnetized permanent-magnet linear machine

    Directory of Open Access Journals (Sweden)

    Yi Sui

    2017-05-01

    Full Text Available A single-phase tubular permanent-magnet linear machine (PMLM with hybrid Halbach/axially-magnetized PM arrays is proposed for free-piston Stirling power generation system. Machine topology and operating principle are elaborately illustrated. With the sinusoidal speed characteristic of the free-piston Stirling engine considered, the proposed machine is designed and calculated by finite-element analysis (FEA. The main structural parameters, such as outer radius of the mover, radial length of both the axially-magnetized PMs and ferromagnetic poles, axial length of both the middle and end radially-magnetized PMs, etc., are optimized to improve both the force capability and power density. Compared with the conventional PMLMs, the proposed machine features high mass and volume power density, and has the advantages of simple control and low converter cost. The proposed machine topology is applicable to tubular PMLMs with any phases.

  6. A tubular hybrid Halbach/axially-magnetized permanent-magnet linear machine

    Science.gov (United States)

    Sui, Yi; Liu, Yong; Cheng, Luming; Liu, Jiaqi; Zheng, Ping

    2017-05-01

    A single-phase tubular permanent-magnet linear machine (PMLM) with hybrid Halbach/axially-magnetized PM arrays is proposed for free-piston Stirling power generation system. Machine topology and operating principle are elaborately illustrated. With the sinusoidal speed characteristic of the free-piston Stirling engine considered, the proposed machine is designed and calculated by finite-element analysis (FEA). The main structural parameters, such as outer radius of the mover, radial length of both the axially-magnetized PMs and ferromagnetic poles, axial length of both the middle and end radially-magnetized PMs, etc., are optimized to improve both the force capability and power density. Compared with the conventional PMLMs, the proposed machine features high mass and volume power density, and has the advantages of simple control and low converter cost. The proposed machine topology is applicable to tubular PMLMs with any phases.

  7. A high temperature hybrid photovoltaic-thermal receiver employing spectral beam splitting for linear solar concentrators

    Science.gov (United States)

    Mojiri, Ahmad; Stanley, Cameron; Rosengarten, Gary

    2015-09-01

    Hybrid photovoltaic/thermal (PV-T) solar collectors are capable of delivering heat and electricity concurrently. Implementing such receivers in linear concentrators for high temperature applications need special considerations such as thermal decoupling of the photovoltaic (pv) cells from the thermal receiver. Spectral beam splitting of concentrated light provides an option for achieving this purpose. In this paper we introduce a relatively simple hybrid receiver configuration that spectrally splits the light between a high temperature thermal fluid and silicon pv cells using volumetric light filtering by semi-conductor doped glass and propylene glycol. We analysed the optical performance of this device theoretically using ray tracing and experimentally through the construction and testing of a full scale prototype. The receiver was mounted on a commercial parabolic trough concentrator in an outdoor experiment. The prototype receiver delivered heat and electricity at total thermal efficiency of 44% and electrical efficiency of 3.9% measured relative to the total beam energy incident on the primary mirror.

  8. Determination of metaldehyde in suspected cases of animal poisoning using gas chromatography-ion trap mass spectrometry.

    Science.gov (United States)

    Jones, A; Charlton, A

    1999-11-01

    A method was developed to detect the molluscicide metaldehyde in samples of stomach contents for forensic toxicology investigations. Gas chromatography-ion trap mass spectrometry in full-scan mode was used to identify and quantify metaldehyde. The limit of detection based on mass chromatograms for the m/z 89 ion was 3 microg/g. Mean recoveries from six different spiked samples were 74% at 25 microg/g and 94% at 500 microg/g. The relative standard deviation of six replicate determinations of a sample containing 632 microg/g metaldehyde was 7.3%.

  9. Identification of two-dimensional electrophoresis-separated proteins in human hepatoma cell by electrospray ion trap mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    As one of the most important analytical methods in proteome research, mass spectrometry was utilized to identify proteins separated by two-dimensional electrophoresis in the human hepatoma cell line BEL-7404. The protein spots were excised from the gel, followed by in-gel digestion, and the peptide mappings were analyzed by liquid chromatography electrospray ion trap mass spectrometer. Nine proteins were identified via database searching, according to the molecular weights and amino acid sequences of peptides, among which two proteins have not been identified in the other liver-cell database. The sequence coverage was 21%-72%. Furthermore, the relationship between the expressed proteins and the liver carcinoma was discussed.

  10. A Dual Source Ion Trap Mass Spectrometer for the Mars Organic Molecule Analyzer of ExoMars 2018

    Science.gov (United States)

    Brickerhoff, William B.; vanAmerom, F. H. W.; Danell, R. M.; Arevalo, R.; Atanassova, M.; Hovmand, L.; Mahaffy, P. R.; Cotter, R. J.

    2011-01-01

    We present details on the objectives, requirements, design and operational approach of the core mass spectrometer of the Mars Organic Molecule Analyzer (MOMA) investigation on the 2018 ExoMars mission. The MOMA mass spectrometer enables the investigation to fulfill its objective of analyzing the chemical composition of organic compounds in solid samples obtained from the near surface of Mars. Two methods of ionization are realized, associated with different modes of MOMA operation, in a single compact ion trap mass spectrometer. The stringent mass and power constraints of the mission have led to features such as low voltage and low frequency RF operation [1] and pulse counting detection.

  11. Simulating Cometary and Stellar X-ray Emission in the Laboratory Using Microcalorimeters and an Electron Beam Ion Trap

    Science.gov (United States)

    Brown, G. V.; Beiersdorfer, P.; Chen, H.; Graf, A.; May, M.; Terracol, S.; Thorn, D.; Boyce, K. R.; Cottam, J.; Gendreau, K. C.; Kahn, S. M.; Kelley, R. L.; Kilbourne, C. A.; Porter, F. S.; Szymkowiak, A. E.

    2004-10-01

    The mixing of atomic and macroscopic processes taking place in non-terrestrial objects creates complex, dynamic, and intriguing environments. High resolution x-ray spectra from these sources measured by satellites such as Chandra, XMM-Newton, and the Solar Maximum Mission provide a means for understanding the physics governing these sources. Laboratory measurements of the atomic processes have proved crucial to the interpretation of these spectra. For example using the LLNL electron beam ion traps EBIT-I & EBIT-II a detailed study of the x-ray spectrum of Fe XVII has been conducted addressing the large ratio predicted by theory compared to observations of considerably smaller values of the relative intensity of the 2p-3d 1P1 resonant to the 3D1 intercombination line. The difference was often attributed to opacity effects. However, laboratory measurements in the optically thin limit agree with observations demonstrating that the prediction is too large and opacity need not be invoked. The laboratory results thus provide a benchmark in the optically thin limit for accurate estimates of opacity effects . To uncover the source of the discrepancy between theory and observation, we have performed a series of experiments that successively uncovered more details about the Fe XVII lines produced in coronal plasmas. Most recently, we used a 32 channel array microcalorimeter from the Astro-E x-ray satellite program to measure the excitation cross section of various Fe XVII lines in the laboratory. These measurements resolve long-standing issues thought to be associated with non-equilibrium processes. We have also used the Astro-E microcalorimeter, and more recently its upgrade from the Astro-E2 project, and the magnetic trapping mode of EBIT-I to accurately measure x-ray emission from charge exchange recombination and to simulate the x-ray line production process in comets. Using only the laboratory measurements, we fit the moderate resolution x-ray spectrum from the comet C/Linear

  12. Electron beam ion trap bi-annual report 1996/1997

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, D

    1999-01-05

    The research of the EBIT (Electron Beam Ion Trap) program in N Division of the Physics and Space Technology Directorate at LLNL continues to contribute significantly to the understanding of physical processes with low energy highly charged ions in atomic physics, plasma physics, and material science. Low-energy highly charged ions (up to U92+), provided by the EBIT facilities, provide a unique laboratory opportunity to study high field effects in atomic structures and dynamic interaction processes. The formation, existence, and structure of highly charged ions in astrophysical environments and laboratory plasmas make highly charged ions desirable for diagnosing various plasma conditions. The strong interaction of highly charged ions with matter and the response of solid surfaces make them a sensitive analysis tool and possibly a future capability for materials modifications at the atomic scale (nano technology). These physical applications require a good understanding and careful study of the dynamics of the interactions of the ions with complex systems. The EBIT group hosted an international conference and a workshop on trapped charged particles. The various talks and discussions showed that physics research with trapped charged particles is a very active and attractive area of innovative research, and provides a basis for research efforts in new areas. It also became obvious that the EBIT/RETRAP project has unique capabilities to perform important new experiments with trapped very highly charged ions at rest, which are complementary to and competitive with research at heavy ion storage rings and other trapping facilities planned or in operation in Europe, Japan, and the United States. Atomic structure research at EBIT provides ever better and more experimental complete benchmark data, supplying data needed to improve atomic theories. Research highlights through 1996 and 1997 include hyperfine structure measurements in H-like ions, QED studies, lifetime

  13. Statistical Model to Analyze Quantitative Proteomics Data Obtained by 18O/16O Labeling and Linear Ion Trap Mass Spectrometry

    Science.gov (United States)

    Jorge, Inmaculada; Navarro, Pedro; Martínez-Acedo, Pablo; Núñez, Estefanía; Serrano, Horacio; Alfranca, Arántzazu; Redondo, Juan Miguel; Vázquez, Jesús

    2009-01-01

    Statistical models for the analysis of protein expression changes by stable isotope labeling are still poorly developed, particularly for data obtained by 16O/18O labeling. Besides large scale test experiments to validate the null hypothesis are lacking. Although the study of mechanisms underlying biological actions promoted by vascular endothelial growth factor (VEGF) on endothelial cells is of considerable interest, quantitative proteomics studies on this subject are scarce and have been performed after exposing cells to the factor for long periods of time. In this work we present the largest quantitative proteomics study to date on the short term effects of VEGF on human umbilical vein endothelial cells by 18O/16O labeling. Current statistical models based on normality and variance homogeneity were found unsuitable to describe the null hypothesis in a large scale test experiment performed on these cells, producing false expression changes. A random effects model was developed including four different sources of variance at the spectrum-fitting, scan, peptide, and protein levels. With the new model the number of outliers at scan and peptide levels was negligible in three large scale experiments, and only one false protein expression change was observed in the test experiment among more than 1000 proteins. The new model allowed the detection of significant protein expression changes upon VEGF stimulation for 4 and 8 h. The consistency of the changes observed at 4 h was confirmed by a replica at a smaller scale and further validated by Western blot analysis of some proteins. Most of the observed changes have not been described previously and are consistent with a pattern of protein expression that dynamically changes over time following the evolution of the angiogenic response. With this statistical model the 18O labeling approach emerges as a very promising and robust alternative to perform quantitative proteomics studies at a depth of several thousand proteins. PMID:19181660

  14. Evaluation of the metabolism of propranolol by linear ion trap technology in mouse, rat, dog, monkey, and human cryopreserved hepatocytes.

    Science.gov (United States)

    Baughman, Todd M; Talarico, Christine L; Soglia, John R

    2009-07-01

    Propranolol is a widely used quality control and validation compound for liver microsome and hepatocyte metabolism studies. A multitude of literature reports describing the identification of propranolol metabolites exists today. However, no literature reports currently exist showing hepatocyte metabolism across the five species commonly used during pre-clinical drug discovery, namely mouse, rat, dog, monkey, and human. Herein, we present full metabolic profiles of propranolol in mouse, rat, dog, monkey and human hepatocytes. As expected, extensive phase I and phase II metabolism was observed across all five species and species-specific metabolites were detected in monkey and dog hepatocytes. Of particular interest was the detection of an N-hydroxylamine glucuronide metabolite in monkey and dog hepatocytes.

  15. Characterization of phthiocerol and phthiodiolone dimycocerosate esters of M. tuberculosis by multiple-stage linear ion-trap mass spectrometry

    NARCIS (Netherlands)

    Flentie, Kelly N; Stallings, Christina L; Turk, John; Minnaard, Adriaan J; Hsu, Fong-Fu

    2015-01-01

    Both phthiocerol/phthiodiolone dimycocerosate (PDIM) and phenolic glycolipids (PGL) are abundant virulent lipids in the cell wall of various pathogenic mycobacteria, which can synthesize a wide range of complex high molecular weight lipids. In this report, we describe LIT MSn mass spectrometric appr

  16. Analysis of 32 toxic natural substances in herbal products by liquid chromatography quadrupole linear ion trap mass spectrometry.

    Science.gov (United States)

    Zeng, Yun; Quek, Yi-Ling; Kee, Chee-Leong; Low, Min-Yong; Bloodworth, Bosco C; Ge, Xiaowei

    2015-11-10

    In this study, an LC-MS/MS EPI method was developed for simultaneous determination of 32 toxic natural substances in herbal products. The analytes include aconite alkaloids, lobelia alkaloids, solanaceous alkaloids, digitalis steroid glycosides, strychnine, tetrahydropalmatine etc. They werecommonly used in herbal products. The target analytes were extracted from the samples using theQuEChERS method and analysed using AB SCIEX QTRAP 5500 coupled with Agilent HPLC 1260. Thecolumn used was biphenyl reversed phase analytical column. Mobile phase A and B were deionizedwater and methanol respectively, both containing 5mM ammonium formate and 0.1% formic acid. TheMRM-IDA-EPI method enabled quantification and confirmation of the analytes in a single run. The EPIwas used for the qualitative analysis while the MRM was used for the quantitative analysis. Limits ofdetection were determined to be below 10μg/kg for the majority of the analytes. The recoveries forthose commonly detected natural substances were in the acceptable range of 70-120%. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Characterization of phthiocerol and phthiodiolone dimycocerosate esters of M. tuberculosis by multiple-stage linear ion-trap mass spectrometry

    NARCIS (Netherlands)

    Flentie, Kelly N; Stallings, Christina L; Turk, John; Minnaard, Adriaan J; Hsu, Fong-Fu

    2015-01-01

    Both phthiocerol/phthiodiolone dimycocerosate (PDIM) and phenolic glycolipids (PGL) are abundant virulent lipids in the cell wall of various pathogenic mycobacteria, which can synthesize a wide range of complex high molecular weight lipids. In this report, we describe LIT MSn mass spectrometric

  18. Infrared ion spectroscopy in a modified quadrupole ion trap mass spectrometer at the FELIX free electron laser laboratory

    Science.gov (United States)

    Martens, Jonathan; Berden, Giel; Gebhardt, Christoph R.; Oomens, Jos

    2016-10-01

    We report on modifications made to a Paul-type quadrupole ion trap mass spectrometer and discuss its application in infrared ion spectroscopy experiments. Main modifications involve optical access to the trapped ions and hardware and software coupling to a variety of infrared laser sources at the FELIX infrared free electron laser laboratory. In comparison to previously described infrared ion spectroscopy experiments at the FELIX laboratory, we find significant improvements in efficiency and sensitivity. Effects of the trapping conditions of the ions on the IR multiple photon dissociation spectra are explored. Enhanced photo-dissociation is found at lower pressures in the ion trap. Spectra obtained under reduced pressure conditions are found to more closely mimic those obtained in the high-vacuum conditions of an Fourier transform ion cyclotron resonance mass spectrometer. A gas-mixing system is described enabling the controlled addition of a secondary gas into helium buffer gas flowing into the trap and allows for ion/molecule reactions in the trap. The electron transfer dissociation (ETD) option of the mass spectrometer allows for IR structure characterization of ETD-generated peptide dissociation products.

  19. An aircraft-borne chemical ionization – ion trap mass spectrometer (CI-ITMS for fast PAN and PPN measurements

    Directory of Open Access Journals (Sweden)

    H. Schlager

    2011-02-01

    Full Text Available An airborne chemical ionization ion trap mass spectrometer instrument (CI-ITMS has been developed for tropospheric and stratospheric fast in-situ measurements of PAN (peroxyacetyl nitrate and PPN (peroxypropionyl nitrate. The first scientific deployment of the FASTPEX instrument (FASTPEX = Fast Measurement of Peroxyacyl nitrates took place in the Arctic during 18 missions aboard the DLR research aircraft Falcon, within the framework of the POLARCAT-GRACE campaign in the summer of 2008. The FASTPEX instrument is described and characteristic properties of the employed ion trap mass spectrometer are discussed. Atmospheric data obtained at altitudes of up to ~12 km are presented, from the boundary layer to the lowermost stratosphere. Data were sampled with a time resolution of 2 s and a 2σ detection limit of 25 pmol mol−1. An isotopically labelled standard was used for a permanent on-line calibration. For this reason the accuracy of the PAN measurements is better than ±10% for mixing ratios greater than 200 pmol mol−1. PAN mixing ratios in the summer Arctic troposphere were in the order of a few hundred pmol mol−1 and generally correlated well with CO. In the Arctic boundary layer and lowermost stratosphere smaller PAN mixing ratios were observed due to a combination of missing local sources of PAN precursor gases and efficient removal processes (thermolysis/photolysis. PPN, the second most abundant PAN homologue, was measured simultaneously. Observed PPN/PAN ratios range between ~0.03 and 0.3.

  20. Decomposition of cyclohexane ion induced by intense femtosecond laser fields by ion-trap time-of-flight mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Takao; Watanabe, Yusuke; Kanya, Reika [Department of Chemistry, School of Science, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Yamanouchi, Kaoru, E-mail: kaoru@chem.s.u-tokyo.ac.jp [Department of Chemistry, School of Science, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); NANOQUINE, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan)

    2016-01-14

    Decomposition of cyclohexane cations induced by intense femtosecond laser fields at the wavelength of 800 nm is investigated by ion-trap time-of-flight mass spectrometry in which cyclohexane cations C{sub 6}H{sub 12}{sup +} stored in an ion trap are irradiated with intense femtosecond laser pulses and the generated fragment ions are recorded by time-of-flight mass spectrometry. The various fragment ion species, C{sub 5}H{sub n}{sup +} (n = 7, 9), C{sub 4}H{sub n}{sup +} (n = 5–8), C{sub 3}H{sub n}{sup +} (n = 3–7), C{sub 2}H{sub n}{sup +} (n = 2–6), and CH{sub 3}{sup +}, identified in the mass spectra show that decomposition of C{sub 6}H{sub 12}{sup +} proceeds efficiently by the photo-irradiation. From the laser intensity dependences of the yields of the fragment ion species, the numbers of photons required for producing the respective fragment ions are estimated.

  1. High-cooling-efficiency cryogenic quadrupole ion trap and UV-UV hole burning spectroscopy of protonated tyrosine

    Science.gov (United States)

    Ishiuchi, Shun-ichi; Wako, Hiromichi; Kato, Daichi; Fujii, Masaaki

    2017-02-01

    The cooling efficiency of a cryogenic three-dimensional quadrupole ion trap (QIT) is drastically improved by using copper electrodes instead of conventional stainless-steel ones. The temperature of trapped ions (protonated tyrosine TyrH+) was estimated based on the ultraviolet (UV) photo-dissociation spectra. The UV spectrum of TryH+ shows almost no hot bands, and thus the high cooling efficiency of the copper ion trap was proven. The temperature was also estimated by simulating the observed band contour in the UV spectra, which is determined by the population in the rotationally excited levels. From the simulations, the temperature of TryH+ was estimated to be ∼13 K, while that in the stainless-steel QIT was 45-50 K. In addition, to demonstrate the advantage of the copper QIT, UV-UV hole burning (HB) spectra, i.e. conformation-selected UV spectra, were measured. It was confirmed that four different conformers, A∼D, coexist in the ultra-cold protonated tyrosine. By comparing with the calculated Franck-Condon spectra, their structural assignments were discussed, including the orientation of the OH group.

  2. Matrix-assisted laser desorption ion trap mass spectrometry: efficient isolation and effective fragmentation of peptide ions.

    Science.gov (United States)

    Qin, J; Chait, B T

    1996-07-01

    Effective analysis of the sequence of peptides using matrix-assisted laser desorption/ionization (MALDI) tandem ion trap mass spectrometry requires efficient mass isolation and the ability to induce extensive sequence-specific fragmentation. The present paper describes a new excitation scheme, which we term red-shifted off-resonance large-amplitude excitation (RSORLAE), that can deposit higher amounts of internal energy in ions than is feasible with conventional resonant excitation. The new method provides an effective means for inducing fragmentation of MALDI-produced peptide ions with m/z values up to 3500. Prior to excitation, it is necessary to isolate ions of interest with high efficiency. We demonstrate that isolation efficiencies of > 95% can be achieved by careful design of the rf scan functions used during ion isolation. In particular, sudden transitions in the amplitude of the rf field (from low to high amplitudes) must be avoided. The combined improvements in the efficiency for ion isolation and the efficacy of ion activation make MALDI tandem ion trap mass spectrometry a practical tool for the characterization of proteins with high sensitivity.

  3. Quasi-linear modeling of lower hybrid current drive in ITER and DEMO

    Energy Technology Data Exchange (ETDEWEB)

    Cardinali, A., E-mail: alessandro.cardinali@enea.it; Cesario, R.; Panaccione, L.; Santini, F.; Amicucci, L.; Castaldo, C.; Ceccuzzi, S.; Mirizzi, F.; Tuccillo, A. A. [ENEA, Unità Tecnica Fusione, Via E Fermi 45 Rome (Italy)

    2015-12-10

    First pass absorption of the Lower Hybrid waves in thermonuclear devices like ITER and DEMO is modeled by coupling the ray tracing equations with the quasi-linear evolution of the electron distribution function in 2D velocity space. As usually assumed, the Lower Hybrid Current Drive is not effective in a plasma of a tokamak fusion reactor, owing to the accessibility condition which, depending on the density, restricts the parallel wavenumber to values greater than n{sub ∥crit} and, at the same time, to the high electron temperature that would enhance the wave absorption and then restricts the RF power deposition to the very periphery of the plasma column (near the separatrix). In this work, by extensively using the “ray{sup star}” code, a parametric study of the propagation and absorption of the LH wave as function of the coupled wave spectrum (as its width, and peak value), has been performed very accurately. Such a careful investigation aims at controlling the power deposition layer possibly in the external half radius of the plasma, thus providing a valuable aid to the solution of how to control the plasma current profile in a toroidal magnetic configuration, and how to help the suppression of MHD mode that can develop in the outer part of the plasma. This analysis is useful not only for exploring the possibility of profile control of a pulsed operation reactor as well as the tearing mode stabilization, but also in order to reconsider the feasibility of steady state regime for DEMO.

  4. Liquid chromatography tandem mass spectrometric quantitation of sulfamethazine and its metabolites: direct analysis of swine urine by triple quadrupole and by ion trap mass spectrometry.

    Science.gov (United States)

    Bartolucci, G; Pieraccini, G; Villanelli, F; Moneti, G; Triolo, A

    2000-01-01

    This work describes a new method for the quantitation of trace amounts of sulfamethazine (SMZ) and its main metabolite, N4-acetylsulfamethazine (Ac-SMZ), in swine urine, using high-performance liquid chromatography (HPLC) tandem mass spectrometric analysis of crude urine after addition of internal standard and simple dilution with water. The aim was to determine whether residues of this sulfamidic drug, normally administered to swine in order to prevent infectious diseases, were present in urine at levels lower than those permitted by regulatory authorities before human consumption (EU Project SMT, contract number CT 96-2092). A 10 microL volume of diluted urine was injected into a very short, narrow-bore chromatographic column (Zorbax SB-C18 2.1 i. d. x30 mm length, 3.5 microm pore size). Elution of the analytes of interest was achieved in less than seven minutes using a rapid gradient (from 20 to 80% methanol in 3 minutes). Either a PE Sciex API 365 triple quadrupole (QqQ), operated in the selected reaction monitoring (SRM) mode, or a Finnigan LCQ ion trap (IT) mass spectrometer, operated in narrow-range product ion scan, was used as the final detector. Electrospray (ESI) was used as the ionization technique. A comparison of the two tandem mass spectrometers was performed by analyzing the same set of test samples, at three concentration levels, on three different days. Linearity of responses of the calibration standards, intra- and inter-assay precision of the samples, specificity and limits of detection were evaluated for both systems. Both the QqQ and the IT instrument was suitable for rapid, sensitive and specific determination of the analytes, although the overall performance of the QqQ was slightly superior in terms of linearity, precision and sensitivity.

  5. Propagator for the general time-dependent harmonic oscillator with application to an ion trap

    Energy Technology Data Exchange (ETDEWEB)

    Harari, Gal; Ben-Aryeh, Yacob; Mann, Ady [Department of Physics, Technion-Israel Institute of Technology, IL-32000 Haifa (Israel)

    2011-12-15

    We present the simplest possible formula for the propagator of the general time-dependent quadratic Hamiltonian, including linear terms. The method is based on the use of a linear time-dependent invariant and requires only the solution of a linear homogeneous second-order ordinary differential equation corresponding to the classical quadratic Hamiltonian. We give an example for the case of the Paul trap.

  6. Optimal Design of Stochastic Distributed Order Linear SISO Systems Using Hybrid Spectral Method

    Directory of Open Access Journals (Sweden)

    Pham Luu Trung Duong

    2015-01-01

    Full Text Available The distributed order concept, which is a parallel connection of fractional order integrals and derivatives taken to the infinitesimal limit in delta order, has been the main focus in many engineering areas recently. On the other hand, there are few numerical methods available for analyzing distributed order systems, particularly under stochastic forcing. This paper proposes a novel numerical scheme for analyzing the behavior of a distributed order linear single input single output control system under random forcing. The method is based on the operational matrix technique to handle stochastic distributed order systems. The existing Monte Carlo, polynomial chaos, and frequency methods were first adapted to the stochastic distributed order system for comparison. Numerical examples were used to illustrate the accuracy and computational efficiency of the proposed method for the analysis of stochastic distributed order systems. The stability of the systems under stochastic perturbations can also be inferred easily from the moment of random output obtained using the proposed method. Based on the hybrid spectral framework, the optimal design was elaborated on by minimizing the suitably defined constrained-optimization problem.

  7. Development and validation of highly selective screening and confirmatory methods for the qualitative forensic analysis of organic explosive compounds with high performance liquid chromatography coupled with (photodiode array and) LTQ ion trap/Orbitrap mass spectrometric detections (HPLC-(PDA)-LTQOrbitrap).

    Science.gov (United States)

    Xu, Xiaoma; Koeberg, Mattijs; Kuijpers, Chris-Jan; Kok, Eric

    2014-01-01

    An LTQ-Orbitrap FTMS is a new (hybrid) mass spectrometric (MS) analyzer. It allows for the acquisition of full scan MS(n) (n-stage fragmentations, n=1-n) spectra with the linear ion trap detector (LTQ) at high speed and/or with the Fourier Transform-detector (Orbitrap) with ultra high mass resolution (>60,000 at m/zphoto diode array (PDA) detection. Two methods for the forensic screening and confirmation of all common trace explosives in post-blast residues have been developed on this instrument using atmospheric pressure chemical ionization (APCI). In one run, the nitrogen-containing explosives are analyzed with the combination of "LC-(PDA)-APCI(-)-LTQ MS(2)/Orbitrap FTMS" (Method 1). In another run, peroxide explosives are analyzed with "LC-APCI(+)-LTQ MS(2)/Orbitrap FTMS" (Method 2). The performance of both methods has been validated according to procedures defined in the EU COMMISSION DECISION implementing Council Directive 96/23/EC concerning the performance of analytical methods and the interpretation of results (DC 2002/657/EC) and other standards (NEN 17025 and NEN 7777). The methods are highly selective due to the simultaneous utilization of the Orbitrap FTMS and LTQ MS(2), both of which are highly selective detectors Tested explosive compounds can be detected in the molecular ion form by the Orbitrap analyzer with minimal mass interference in different matrices when using an extremely narrow mass tolerance detection window (≤2ppm). The identification of a detected compound follows an identification point system. Experimental results show that almost all explosive compounds meet the confirmation criteria (minimum 4 points) required for the positive identification by the DC 2002/657/EC.

  8. Multiwalled carbon nanotubes as a solid-phase extraction adsorbent for the determination of three barbiturates in pork by ion trap gas chromatography-tandem mass spectrometry (GC/MS/MS) following microwave assisted derivatization

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Haixiang [College of Science, China Agricultural University, Beijing 100094 (China); Inspection Technology and Equipment Institute, Chinese Academy of Inspection and Quarantine, Beijing 100025 (China); Department of Basic Agricultural Science, Hebei North College, Zhangjiakou Hebei 075131 (China); Wang Liping [College of Science, China Agricultural University, Beijing 100094 (China); Qiu Yueming [Inspection Technology and Equipment Institute, Chinese Academy of Inspection and Quarantine, Beijing 100025 (China); Zhou Zhiqiang [College of Science, China Agricultural University, Beijing 100094 (China)]. E-mail: zqzhou@cau.edu.cn; Zhong Weike [Inspection Technology and Equipment Institute, Chinese Academy of Inspection and Quarantine, Beijing 100025 (China); Li Xiang [Inspection Technology and Equipment Institute, Chinese Academy of Inspection and Quarantine, Beijing 100025 (China)

    2007-03-14

    A new method was developed for the rapid screening and confirmation analysis of barbital, amobarbital and phenobarbital residues in pork by gas chromatography-tandem mass spectrometry (GC/MS/MS) with ion trap MSD. The residual barbiturates in pork were extracted by ultrasonic extraction, cleaned up on a multiwalled carbon nanotubes (MWCNTs) packed solid phase extraction (SPE) cartridge and applied acetone-ethyl acetate (3:7, v/v) mixture as eluting solvent and derivatized with CH{sub 3}I under microwave irradiation. The methylated barbiturates were separated on a TR-5MS capillary column and detected with an ion trap mass detector. Electron impact ion source (EI) operating MS/MS mode was adopted for identification and external standard method was employed for quantification. One precursor ion m/z 169 was selected for analysis of barbital and amobarbital and m/z 232 was selected for phenobarbital. The product ions were obtained under 1.0 V excitation voltage. Good linearities (linear coefficient R > 0.99) were obtained at the range of 0.5-50 {mu}g kg{sup -1}. Limit of detection (LOD) of barbital was 0.2 {mu}g kg{sup -1} and that of amobarbital and phenobarbital were both 0.1 {mu}g kg{sup -1} (S/N {>=} 3). Limit of quatification (LOQ) was 0.5 {mu}g kg{sup -1} for three barbiturates (S/N {>=} 10). Satisfying recoveries ranging from 75% to 96% of the three barbiturates spiked in pork were obtained, with relative standard deviations (R.S.D.) in the range of 2.1-7.8%.

  9. Dynamical Linear Response of TDDFT with LDA+U Functional: Strongly Hybridized Frenkel Excitons in NiO

    Energy Technology Data Exchange (ETDEWEB)

    Lee, C.C.; Ku, W.; Hsueh, H.C.

    2010-08-30

    Within the framework of time-dependent density-functional theory (TDDFT), we derive the dynamical linear response of local-density approximation plus U functional and benchmark it on NiO, a prototypical Mott insulator. Formulated using real-space Wannier functions, our computationally inexpensive framework gives detailed insights into the formation of tightly bound Frenkel excitons with reasonable accuracy. Specifically, a strong hybridization of multiple excitons is found to significantly modify the exciton properties. Furthermore, our study exposes a significant generic limitation of adiabatic approximation in TDDFT with hybrid functionals and in existing Bethe-Salpeter-equation approaches, advocating the necessity of strongly energy-dependent kernels in future development.

  10. Sequencing and characterization of oligosaccharides using infrared multiphoton dissociation and boronic acid derivatization in a quadrupole ion trap.

    Science.gov (United States)

    Pikulski, Michael; Hargrove, Amanda; Shabbir, Shagufta H; Anslyn, Eric V; Brodbelt, Jennifer S

    2007-12-01

    A simplified method for determining the sequence and branching of oligosaccharides using infrared multiphoton dissociation (IRMPD) in a quadrupole ion trap (QIT) is described. An IR-active boronic acid (IRABA) reagent is used to derivatize the oligosaccharides before IRMPD analysis. The IRABA ligand is designed to both enhance the efficiency of the derivatization reaction and to facilitate the photon absorption process. The resulting IRMPD spectra display oligosaccharide fragments that are formed from primarily one type of diagnostic cleavage, thus making sequencing straightforward. The presence of sequential fragment ions, a phenomenon of IRMPD, permit the comprehensive sequencing of the oligosaccharides studied in a single stage of activation. We demonstrate this approach for two series of oligosaccharides, the lacto-N-fucopentaoses (LNFPs) and the lacto-N-difucohexaoses (LNDFHs).

  11. Identification of phosphorylation sites of proteins by high performance liquid chromatography-electrospray ionization-quadrupole ion trap mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The phosphorylation sites of two phosphorylated proteins, bovine b-casein and myelin basic protein (MBP), were identified by high performance liquid chromatography-electrospray ionization-quadrupole ion trap mass spectrometry (HPLC-ESI-QITMS). The tryptic digest of each protein was separated by HPLC, the molecular weight of each peptide was determined by ESI-QITMS on line, and MS/MS spectrum of each peptide was simultaneously obtained by the combination of collision-induced desorption (CID) technique and tandem mass spectrometry (MS/MS) of QITMS. The phosphorylated peptide was identified by looking into whether the difference between the observed and predicted molecular weights of a peptide is 80 u or its integral multiple. Then the phosphorylation site was identified through manual interpretation of the MS/MS spectrum of the phosphorylated peptide or automatic SEQUEST data base-searching.

  12. Identification of phosphorylation sites of proteins by high performance liquid chromatography-electrospray ionization-quadrupole ion trap mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    车发云; 邵晓霞; 夏其昌

    2000-01-01

    The phosphorylation sites of two phosphorylated proteins, bovine β-casein and myelin basic protein (MBP), were identified by high performance liquid chromatography-electrospray ionization-quadrupole ion trap mass spectrometry (HPLC-ESI-QITMS). The tryptic digest of each protein was separated by HPLC, the molecular weight of each peptide was determined by ESI-QITMS on line, and MS/MS spectrum of each peptide was simultaneously obtained by the combination of collision-induced desorption (CID) technique and tandem mass spectrometry (MS/MS) of QITMS. The phosphorylated peptide was identified by looking into whether the difference between the observed and predicted molecular weights of a peptide is 80 u or its integral multiple. Then the phosphorylation site was identified through manual interpretation of the MS/MS spectrum of the phosphorylated peptide or automatic SEQUEST data base-searching.

  13. The detection of piroxicam, tenoxicam and their metabolites in equine urine by electrospray ionisation ion trap mass spectrometry.

    Science.gov (United States)

    McKinney, Andrew R; Suann, Craig J; Stenhouse, Allen M

    2004-01-01

    An investigation has been conducted into the metabolism and urinary excretion of orally administered piroxicam and tenoxicam in the horse. The major component detected in urine after the administration of piroxicam was 5'-hydroxypiroxicam, which was detectable up to 24 h post-administration. Unchanged piroxicam was present only as a minor component. In contrast, unchanged tenoxicam was the major component observed after the administration of tenoxicam, being detectable for 72 h post-administration, while 5'-hydroxytenoxicam was a minor component. Phase II beta-glucuronide conjugation in each case was found to be negligible. The ion trap mass spectral characteristics of piroxicam, tenoxicam, 5'-hydroxypiroxicam and 5'-hydroxytenoxicam under electrospray ionisation conditions were examined in some detail.

  14. Extended-range grazing-incidence spectrometer for high-resolution extreme ultraviolet measurements on an electron beam ion trap

    Energy Technology Data Exchange (ETDEWEB)

    Beiersdorfer, P.; Magee, E. W.; Brown, G. V.; Träbert, E.; Widmann, K. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Hell, N. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Dr. Remeis-Sternwarte and ECAP, Universität Erlangen-Nürnberg, 96049 Bamberg (Germany)

    2014-11-15

    A high-resolution grazing-incidence grating spectrometer has been implemented on the Livermore electron beam ion traps for performing very high-resolution measurements in the soft x-ray and extreme ultraviolet region spanning from below 10 Å to above 300 Å. The instrument operates without an entrance slit and focuses the light emitted by highly charged ions located in the roughly 50 μm wide electron beam onto a cryogenically cooled back-illuminated charge-coupled device detector. The measured line widths are below 0.025 Å above 100 Å, and the resolving power appears to be limited by the source size and Doppler broadening of the trapped ions. Comparisons with spectra obtained with existing grating spectrometers show an order of magnitude improvement in spectral resolution.

  15. Congener specific determination of toxaphene residues in fish liver oil using gas chromatography coupled to ion trap MS/MS.

    Science.gov (United States)

    Bernardo, F J Guzmán; Fernández, M A; González, M J

    2005-10-01

    A new approach to the determination of six toxaphene congeners in edible stuff has been accomplished. The analytical procedure presented in this paper involves a single-step cleanup process prior to the analysis. A solution containing three (13)C labelled polychlorinated biphenyls was used as internal standard and tetrachloronaphtalene was used as injection standard. The analytical technique used was gas chromatography coupled to ion trap mass spectrometry detector in MS/MS mode. The parameters affecting the successive fragmentations were discussed and optimized. The limits of detection ranged from 2 to 49pg microl(-1). The toxaphene congeners were determined in two different fish liver oil pills sold in Spain as a supplementary vitamin support.

  16. Quantitative analysis of [Dmt(1)]DALDA in ovine plasma by capillary liquid chromatography-nanospray ion-trap mass spectrometry.

    Science.gov (United States)

    Wan, Haibao; Umstot, Edward S; Szeto, Hazel H; Schiller, Peter W; Desiderio, Dominic M

    2004-04-15

    The synthetic opioid peptide analog Dmt-D-Arg-Phe-Lys-NH(2) ([Dmt(1)]DALDA; [Dmt= 2',6'-dimethyltyrosine) is a highly potent and selective mu opioid-receptor agonist. A very sensitive and robust capillary liquid chromatography/nanospray ion-trap (IT) mass spectrometry method has been developed to quantify [Dmt(1)]DALDA in ovine plasma, using deuterated [Dmt(1)]DALDA as the internal standard. The standard MS/MS spectra of d(0)- and d(5)-[Dmt(1)]DALDA were obtained, and the collision energy was experimentally optimized to 25%. The product ion [ M + 2H-NH(3)](2+) (m/z 312.2) was used to identify and to quantify the synthetic opioid peptide analog in ovine plasma samples. The MS/MS detection sensitivity for [Dmt(1)]DALDA was 625 amol. A calibration curve was constructed, and quantitative analysis was performed on a series of ovine plasma samples.

  17. Soft-X-ray spectra of highly charged Os, Bi, Th, and U ions in an electron beam ion trap

    Energy Technology Data Exchange (ETDEWEB)

    Trabert, E; Beiersdorfer, P; Fournier, K B; Chen, M H

    2004-12-03

    Systematic variation of the electron-beam energy in an electron-beam ion trap has been employed to produce soft-X-ray spectra of Os, Bi, Th, and U with highest charge states ranging up to Ni-like ions. Guided by relativistic atomic structure calculations, the strongest lines have been identified with {Delta}n = 0 (n = 4 to n' = 4) transitions in Rb- to Cu-like ions. The rather weak 4p-4d transitions are much less affected by QED contributions than the dominant 4s-4p transitions. Our wavelength measurements consequently provide benchmarks with and (almost) without QED. Because the radiative corrections are not very sensitive to the number of electrons in the valence shell, our data, moreover, provide benchmarks for the evaluation of electron-electron interactions.

  18. Spectral measurements of few-electron uranium ions produced and trapped in a high-energy electron beam ion trap

    Energy Technology Data Exchange (ETDEWEB)

    Beiersdorfer, P.

    1994-11-04

    Measurements of 2s{sub l/2}-2p{sub 3/2} electric dipole and 2p{sub 1/2}-2p{sub 3/2} magnetic dipole and electric quadrupole transitions in U{sup 82+} through U{sup 89+} have been made with a high-resolution crystal spectrometer that recorded the line radiation from stationary ions produced and trapped in a high-energy electron beam ion trap. From the measurements we infer {minus}39.21 {plus_minus} 0.23 eV for the QED contribution to the 2s{sub 1/2}-2p{sub 3/2} transition energy of lithiumlike U{sup 89+}. A comparison between our measurements and various computations illustrates the need for continued improvements in theoretical approaches for calculating the atomic structure of ions with two or more electrons in the L shell.

  19. Dielectronic recombination measurements of highly-charged heliumlike and neonlike ions using an electron beam ion trap

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, M.B.; Knapp, D.A.; Beiersdorfer, P.; Chen, M.H.; Scofield, J.H.; Bennett, C.L.; DeWitt, D.R.; Henderson, J.R.; Lee, P.; Marrs, R.E.; Schneider, D. (Lawrence Livermore National Lab., CA (United States)); Levine, M.A. (Lawrence Berkeley Lab., CA (United States))

    1991-01-01

    The electron beam ion trap (EBIT) at LLNL is a unique device designed to measure the interactions of electrons with highly-charged ions. We describe three methods used at EBIT to directly measure the dielectronic recombination (DR) process: the intensity of the stabilizing x-rays is measured as a function of electron beam energy; the ions remaining in a particular ionization state are counted after the electron beam has been held at a fixed electron energy for a fixed time; and high-resolution spectroscopy is used to resolve individual DR satellite lines. In our discussions, we concentrate on the KLL resonances of the heliumlike target ions (V{sup 21+} to Ba{sup 54+}), and the LMM resonances of the neonlike target ions (Xe{sup 44+} to Th{sup 80+}). 12 refs., 8 figs.

  20. Analysis of the fine structure of Sn$^{11+...14+}$ ions by optical spectroscopy in an electron beam ion trap

    CERN Document Server

    Windberger, A; Borschevsky, A; Ryabtsev, A; Dobrodey, S; Bekker, H; Eliav, E; Kaldor, U; Ubachs, W; Hoekstra, R; López-Urrutia, J R Crespo; Versolato, O O

    2016-01-01

    We experimentally re-evaluate the fine structure of Sn$^{11+...14+}$ ions. These ions are essential in bright extreme-ultraviolet (EUV) plasma-light sources for next-generation nanolithography, but their complex electronic structure is an open challenge for both theory and experiment. We combine optical spectroscopy of magnetic dipole $M1$ transitions, in a wavelength range covering 260\\,nm to 780\\,nm, with charge-state selective ionization in an electron beam ion trap. Our measurements confirm the predictive power of \\emph{ab initio} calculations based on Fock space coupled cluster theory. We validate our line identification using semi-empirical Cowan calculations with adjustable wavefunction parameters. Available Ritz combinations further strengthen our analysis. Comparison with previous work suggests that line identifications in the EUV need to be revisited.

  1. Determination of N,N-dimethyltryptamine in beverages consumed in religious practices by headspace solid-phase microextraction followed by gas chromatography ion trap mass spectrometry.

    Science.gov (United States)

    Gaujac, Alain; Dempster, Nicola; Navickiene, Sandro; Brandt, Simon D; de Andrade, Jailson Bittencourt

    2013-03-15

    A novel analytical approach combining solid-phase microextraction (SPME)/gas chromatography ion trap mass spectrometry (GC-IT-MS) was developed for the detection and quantification N,N-dimethyltryptamine (DMT), a powerful psychoactive indole alkaloid present in a variety of South American indigenous beverages, such as ayahuasca and vinho da jurema. These particular plant products, often used within a religious context, are increasingly consumed throughout the world following an expansion of religious groups and the availability of plant material over the Internet and high street shops. The method described in the present study included the use of SPME in headspace mode combined GC-IT-MS and included the optimization of the SPME procedure using multivariate techniques. The method was performed with a polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber in headspace mode (70 min at 60 °C) which resulted in good precision (RSD<8.6%) and accuracy values (71-109%). Detection and quantification limits obtained for DMT were 0.78 and 9.5 mg L(-1), respectively and good linearity (1.56-300 mg L(-1), r(2)=0.9975) was also observed. In addition, the proposed method showed good robustness and allowed for the minimization of sample manipulation. Five jurema beverage samples were prepared in the laboratory in order to study the impact of temperature, pH and ethanol on the ability to extract DMT into solution. The developed method was then applied to the analysis of twelve real ayahuasca and vinho da jurema samples, obtained from Brazilian religious groups, which revealed DMT concentration levels between 0.10 and 1.81 g L(-1). Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Development of a method for comprehensive and quantitative analysis of plant hormones by highly sensitive nanoflow liquid chromatography-electrospray ionization-ion trap mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Izumi, Yoshihiro; Okazawa, Atsushi; Bamba, Takeshi; Kobayashi, Akio [Department of Biotechnology, Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871 (Japan); Fukusaki, Eiichiro, E-mail: fukusaki@bio.eng.osaka-u.ac.jp [Department of Biotechnology, Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871 (Japan)

    2009-08-26

    In recent plant hormone research, there is an increased demand for a highly sensitive and comprehensive analytical approach to elucidate the hormonal signaling networks, functions, and dynamics. We have demonstrated the high sensitivity of a comprehensive and quantitative analytical method developed with nanoflow liquid chromatography-electrospray ionization-ion trap mass spectrometry (LC-ESI-IT-MS/MS) under multiple-reaction monitoring (MRM) in plant hormone profiling. Unlabeled and deuterium-labeled isotopomers of four classes of plant hormones and their derivatives, auxins, cytokinins (CK), abscisic acid (ABA), and gibberellins (GA), were analyzed by this method. The optimized nanoflow-LC-ESI-IT-MS/MS method showed ca. 5-10-fold greater sensitivity than capillary-LC-ESI-IT-MS/MS, and the detection limits (S/N = 3) of several plant hormones were in the sub-fmol range. The results showed excellent linearity (R{sup 2} values of 0.9937-1.0000) and reproducibility of elution times (relative standard deviations, RSDs, <1.1%) and peak areas (RSDs, <10.7%) for all target compounds. Further, sample purification using Oasis HLB and Oasis MCX cartridges significantly decreased the ion-suppressing effects of biological matrix as compared to the purification using only Oasis HLB cartridge. The optimized nanoflow-LC-ESI-IT-MS/MS method was successfully used to analyze endogenous plant hormones in Arabidopsis and tobacco samples. The samples used in this analysis were extracted from only 17 tobacco dry seeds (1 mg DW), indicating that the efficiency of analysis of endogenous plant hormones strongly depends on the detection sensitivity of the method. Our analytical approach will be useful for in-depth studies on complex plant hormonal metabolism.

  3. Rapid and sensitive gas chromatography ion-trap mass spectrometry method for the determination of tobacco specific N-nitrosamines in secondhand smoke

    Energy Technology Data Exchange (ETDEWEB)

    SLEIMAN, Mohamad; MADDALENA, Randy L.; GUNDEL, Lara A.; DESTAILLATS, Hugo

    2009-07-01

    Tobacco-specific nitrosamines (TSNAs) are some of the most potent carcinogens in tobacco and cigarette smoke. Accurate quantification of these chemicals is needed to help assess public health risks. We developed and validated a specific and sensitive method to measure four TSNAs in both the gas- and particle-phase of secondhand smoke (SHS) using gas chromatography and ion-trap tandem mass spectrometry,. A smoking machine in an 18-m3 room-sized chamber generated relevant concentrations of SHS that were actively sampled on Teflon coated fiber glass (TCFG) filters, and passively sampled on cellulose substrates. A simple solid-liquid extraction protocol using methanol as solvent was successfully applied to both filters with high recoveries ranging from 85 to 115percent. Tandem MS parameters were optimized to obtain the best sensitivity in terms of signal to-noise ratio (S/N) for the target compounds. For each TSNA, the major fragmentation pathways as well as ion structures were elucidated and compared with previously published data. The method showed excellent performances with a linear dynamic range between 2 and 1000 ng mL-1, low detection limits (S/N> 3) of 30-300 pg.ml-1 and precision with experimental errors below 10percent for all compounds. Moreover, no interfering peaks were observed indicating a high selectivity of MS/MS without the need for a sample clean up step. The sampling and analysis method provides a sensitive and accurate tool to detect and quantify traces of TSNA in SHS polluted indoor environments.

  4. [Fast screening of 24 sedative hypnotics illegally added in improving sleep health foods by high performance liquid chromatography-ion trap mass spectrometry].

    Science.gov (United States)

    Lu, Li; Gong, Xu; Tan, Li

    2015-03-01

    A fast screening method was established for the simultaneous determination of 24 sedative hypnotics illegally added in improving sleep health foods by high performance liquid chromatography-ion trap mass spectrometry (HPLC-IT MS). The method was based on the sonication assisted extraction of the improving sleep health food samples using methanol. The extract was then filtrated with 0.45 µm filter membrane and the filtrate was separated on a Phenomenex Luna C18 column with isocratic elution at a flow rate of 0.3 mL/min. A binary mobile phase was 0.05% (v/v) formic acid (solvent A)-methanol/acetonitrile (15:25, v/v, solvent B). The electrospray ionization (ESI) source in positive ion mode or negative ion mode was used to scan MS1-MS3 spectra for the 24 sedative hypnotics. The MS2 and MS3 spectra were used for qualitative analysis of samples. The calibration graphs were linear in their concentration ranges with the correlation coefficients (r2) more than 0.999. The limits of detection (LODs) were 4.0-446.6 µg/L. The recoveries for all the drugs in the improving sleep health foods were 88.6%-110.3% with the relative standard deviations no more than 9.8% at three spiked levels. Twenty-seven batches of the improving sleep health foods were tested. Melatonin was found in eighteen batches. The method is fast, specific, sensitive, easy and suitable for fast screening of 24 sedative hypnotics illegally added in improving sleep health foods.

  5. Development of hybrid gas detectors for monitoring neutrons induced from the large intensity proton linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Shim, G. S.; Lee, G. S.; Ahn, S. H. [Korea Univ., Seoul (Korea, Republic of)

    2005-05-15

    Design of a hybrid gaseous detector for slow neutrons. Construction of the hybrid gaseous detector and tests with a {sup 52}Cf isotope and the MC-50 cyclotron. Designs, constructions, and tests for hybrid scintillators using various neutron sensitive materials (2{sup nd} year). Application to development of detectors for high energy physics (2{sup nd} year). Practical R and Ds for applications to medical and industrial purposes (3{sup rd} year)

  6. Isolation of diterpenoid alkaloids from herb and flowers of aconitum napellus ssp. vulgare and electrospray ion trap multiple MS study of these alkaloids

    Science.gov (United States)

    Chen; Koelliker; Oehme; Katz

    1999-05-01

    Chemical investigation of herb and flowers of Aconitum napellus L. ssp. vulgare led to the isolation of 12 diterpenoid alkaloids. Their chemical structures were identified on the basis of NMR and MS and of their complete ion trap multiple fragmentation mass spectrometry study.

  7. Application of the Reversed-phase Liquid Chromatography Coupled to Ion Trap Mass Spectrometry with Principal Components Analysis for Metabonomics Studies of Scutellarin in Rat Urine

    Institute of Scientific and Technical Information of China (English)

    Xiao Rong RAN; Sheng Zhu SI; Qiong Lin LIANG; Guo An LUO

    2006-01-01

    Metabonomics, a novel systemic approach, was applied to studies of Traditional Chinese Medicine scutellarin in rat urine. The liquid chromatography coupled with ion trap mass spectrometry combined with PCA was used in this paper. With this methodology, two potential metabolites of scutellarin were detected and the nine ions responsible for the gender variation and one ion for the dosage variation were found.

  8. Ion suppression in the determination of clenbuterol in urine by solid-phase extraction atmospheric pressure chemical ionisation ion-trap mass spectrometry

    NARCIS (Netherlands)

    van Hout, M.W.J.; Niederlander, H.A G; de Zeeuw, R.A.; de Jong, G.J.

    2003-01-01

    Ion suppression effects were observed during the determination of clenbuterol in urine with solid-phase extraction/multiple-stage ion-trap mass spectrometry (SPE/MS3), despite the use of atmospheric pressure chemical ionisation. During SPE, a polymeric stationary phase (polydivinylbenzene) was appli

  9. Flavor release measurement by atmospheric pressure chemical ionization ion trap mass spectrometry, construction of interface and mathematical modeling of release profiles

    DEFF Research Database (Denmark)

    Haahr, Anne-Mette; Madsen, Henrik; Smedsgaard, Jørn

    2003-01-01

    An instrumental on-line retronasal flavor analysis was developed to obtain information about the release of flavor compounds in expired air from humans during eating. The volatile flavor compounds were measured by ion trap mass spectrometry with an atmospheric pressure chemical ionization source...

  10. Total synthesis of feglymycin based on a linear/convergent hybrid approach using micro-flow amide bond formation

    Science.gov (United States)

    Fuse, Shinichiro; Mifune, Yuto; Nakamura, Hiroyuki; Tanaka, Hiroshi

    2016-11-01

    Feglymycin is a naturally occurring, anti-HIV and antimicrobial 13-mer peptide that includes highly racemizable 3,5-dihydroxyphenylglycines (Dpgs). Here we describe the total synthesis of feglymycin based on a linear/convergent hybrid approach. Our originally developed micro-flow amide bond formation enabled highly racemizable peptide chain elongation based on a linear approach that was previously considered impossible. Our developed approach will enable the practical preparation of biologically active oligopeptides that contain highly racemizable amino acids, which are attractive drug candidates.

  11. Generation of Superpositions of Two Bloch States in an Ion Trap

    Institute of Scientific and Technical Information of China (English)

    ZHENG Shi-Biao

    2003-01-01

    We propose a scheme for the generation of superpositions of two Bloch states for a collection of ions. Inthe scheme the ions are trapped in a linear potential and interact with laser beams. Our scheme does not put anyrequirement on the Lamb-Dicke parameters.

  12. Hybrid Estimation of State and Input for Linear Continuous Time-varying Systems: A Game Theory Approach

    Institute of Scientific and Technical Information of China (English)

    YANGXiao-Jun; WENGZheng-Xin; TIANZuo-Hua; SHISong-Jiao

    2005-01-01

    The H∞ hybrid estimation problem for linear continuous time-varying systems is investigated in this paper, where estimated signals are linear combination of state and input. Design objective requires the worst-case energy gain from disturbance to estimation error be less than a prescribed level. Optimal solution of the hybrid estimation problem is the saddle point of a two-player zero sum differential game. Based on the differential game approach, necessary and sufficient solvable conditions for the hybrid estimation problem are provided in terms of solutions to a Riccati differential equation. Moreover, one possible estimator is proposed if the solvable conditions are satisfied.The estimator is characterized by a gain matrix and an output mapping matrix that reflects the internal relations between the unknown input and output estimation error. Both state and unknown inputs estimation are realized by the proposed estimator. Thus, the results in this paper are also capable of dealing with fault diagnosis problems of linear time-varying systems. At last, a numerical example is provided to illustrate the proposed approach.

  13. Multipole Electrodynamic Ion Trap Geometries for Microparticle Confinement under Standard Ambient Temperature and Pressure Conditions

    CERN Document Server

    Mihalcea, Bogdan M; Stan, Cristina; Visan, Gina T; Ganciu, Mihai; Filinov, Vladimir E; Lapitsky, Dmitry S; Deputatova, Lidiya V; Syrovatka, Roman A

    2015-01-01

    Trapping of microparticles and aerosols is of great interest for physics and chemistry. We report microparticle trapping in multipole linear Paul trap geometries, operating under Standard Ambient Temperature and Pressure (SATP) conditions. An 8-electrode and a 12-electrode linear trap geometries have been designed and tested with an aim to achieve trapping for larger number of particles and to study microparticle dynamical stability in electrodynamic fields. We report emergence of planar and volume ordered structures of the microparticles, depending on the a.c. trapping frequency and particle specific charge ratio. The electric potential within the trap was mapped using the electrolytic tank method. Particle dynamics was simulated using a stochastic Langevin equation. We emphasize extended regions of stable trapping with respect to quadrupole traps, as well as good agreement between experiment and numerical simulations.

  14. Anionic linear-globular dendrimers: biocompatible hybrid materials with potential uses in nanomedicine.

    Science.gov (United States)

    Alavidjeh, Mohammad Shafiee; Haririan, Ismaeil; Khorramizadeh, Mohammad Reza; Ghane, Zohre Zarei; Ardestani, Mehdi Shafiee; Namazi, Hassan

    2010-04-01

    The use of dendrimers as nano-sized excipients/vectors in biological and pharmaceutical systems is dependent on the investigation of their toxicological profiles in biological media. In this study, a series of mechanistic in vitro structure-associated cell toxicity evaluations was performed on the two generations of an anionic linear-globular dendrimer G1 and G2 (where PEG is the core, and citric acid is the periphery) each of which has a different size, charge, and MW. In vitro cytotoxicity behavior of the dendrimers with the methods like crystal violet staining, methyl thiazolyl tetrazolium (MTT), and lactate dehydrogenase (LDH) assays was analyzed. The cell death mechanisms (apoptosis-necrosis) induced by the dendrimers were also evaluated in HT1080 cell line. The impact of the dendrimers on the release of the pro-inflammatory cytokines like TNF-alpha (tumor necrosis factor alpha) and IL1-beta (interleukin 1 beta) was assessed in THP-1 cell line. Hemolysis assay and coagulation studies such as PT (prothrombin time) and APTT (activated partial thromboplastin time) on human blood samples were conducted to examine the interactions of the dendrimers with such bio-environments. The results of cell cytotoxicity experiments and the amounts of IL1-beta and TNF-alpha secretions from THP-1 cell line were consistent with the hemoglobin release from the erythrocytes and the results gained from the coagulation studies. In fact, no significant harmful effect was observed for the dendrimers up to the concentration of 0.5 mg/ml. Both apoptosis and necrosis were ascribed to cell death. The G1 with more flexibility, less negative charge, and greater poly dispersity in size versus the G2 displayed more toxicity than the G2 at the concentration of 1 mg/ml and above in most of the experiments. As a whole, these results suggest a biocompatible range for these hybrid structures up to the concentration of 0.5 mg/ml. Therefore, the potentiality for these structures to be employed in the

  15. Optimisation Sizing of Hybrid Wind-Diesel Systems using Linear Programming Technique

    OpenAIRE

    Gan, Leong Kit; Shek, Jonathan; Mueller, Markus

    2014-01-01

    Despite the great potential of hybrid wind-diesel system in supplying energy to remote or island communities, sizing the system components have been a challenging problem for many project managers due to the reliance on various factors. This work considers utilising a fixed speed wind turbine (induction generator) in the hybrid system. It requires energy for start-up operation and this work takes into account for sizing the battery storage. In addition, the trade-off between the number of bat...

  16. Semiconductor-metal nanoparticle molecules: hybrid excitons and non-linear Fano effect

    OpenAIRE

    Zhang, Wei; Govorov, Alexander O.; Bryant, Garnett W.

    2006-01-01

    Modern nanotechnology opens the possibility of combining nanocrystals of various materials with very different characteristics in one superstructure. The resultant superstructure may provide new physical properties not encountered in homogeneous systems. Here we study theoretically the optical properties of hybrid molecules composed of semiconductor and metal nanoparticles. Excitons and plasmons in such a hybrid molecule become strongly coupled and demonstrate novel properties. At low inciden...

  17. Mobility-Selected Ion Trapping and Enrichment Using Structures for Lossless Ion Manipulations.

    Science.gov (United States)

    Chen, Tsung-Chi; Ibrahim, Yehia M; Webb, Ian K; Garimella, Sandilya V B; Zhang, Xing; Hamid, Ahmed M; Deng, Liulin; Karnesky, William E; Prost, Spencer A; Sandoval, Jeremy A; Norheim, Randolph V; Anderson, Gordon A; Tolmachev, Aleksey V; Baker, Erin S; Smith, Richard D

    2016-02-02

    The integration of ion mobility spectrometry (IMS) with mass spectrometry (MS) and the ability to trap ions in IMS-MS measurements is of great importance for performing reactions, accumulating ions, and increasing analytical measurement sensitivity. The development of Structures for Lossless Ion Manipulations (SLIM) offers the potential for ion manipulations in an extended and more effective manner, while opening opportunities for many more complex sequences of manipulations. Here, we demonstrate an ion separation and trapping module and a method based upon SLIM that consists of a linear mobility ion drift region, a switch/tee and a trapping region that allows the isolation and accumulation of mobility-separated species. The operation and optimization of the SLIM switch/tee and trap are described and demonstrated for the enrichment of the low abundance ions. A linear improvement in ion intensity was observed with the number of trapping/accumulation events using the SLIM trap, illustrating its potential for enhancing the sensitivity of low abundance or targeted species.

  18. Hybrid System Modeling and Full Cycle Operation Analysis of a Two-Stroke Free-Piston Linear Generator

    Directory of Open Access Journals (Sweden)

    Peng Sun

    2017-02-01

    Full Text Available Free-piston linear generators (FPLGs have attractive application prospects for hybrid electric vehicles (HEVs owing to their high-efficiency, low-emissions and multi-fuel flexibility. In order to achieve long-term stable operation, the hybrid system design and full-cycle operation strategy are essential factors that should be considered. A 25 kW FPLG consisting of an internal combustion engine (ICE, a linear electric machine (LEM and a gas spring (GS is designed. To improve the power density and generating efficiency, the LEM is assembled with two modular flat-type double-sided PM LEM units, which sandwich a common moving-magnet plate supported by a middle keel beam and bilateral slide guide rails to enhance the stiffness of the moving plate. For the convenience of operation processes analysis, the coupling hybrid system is modeled mathematically and a full cycle simulation model is established. Top-level systemic control strategies including the starting, stable operating, fault recovering and stopping strategies are analyzed and discussed. The analysis results validate that the system can run stably and robustly with the proposed full cycle operation strategy. The effective electric output power can reach 26.36 kW with an overall system efficiency of 36.32%.

  19. Metabolism of SFZ—47 in chicken embryo by liquid chroma—tography—electrospray ion trap mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    DONGQing-Guang; GUJing-Kai; ZHONGDa-Fang; JPaulFAWCETT; ZHOUHui

    2003-01-01

    AIM:To develop an alternative method for investigation of drug metabolism by fertilized chicken eggs using 3H-1,2-dihydro-2-(4-methyl-phenylamino) methyl-1-pyrrolizinone (SFZ-47) as a probe drug. METHODS:SFZ-47(15 mg) was injected into the albumen of eggs from standardized breed chickens previously incubated for 10d. After 72 h of further incubation, the allantoic liquid was subjected to solid phase extraction on XAD-2 columns and analyzed by liquid chromatography-electrospray ion trap mass spectrometry method. RESULTS: Three major metabolites were identified, namely 4-(3H-1,2-dihydro-1-pyrrolizinone-2-methyl-amino) benzyl alcohol (SFZ-47-OH), 4-(3H-1,2-dihydro-1-pyrrolizinone-2-methyl-amino)-benzoic acid (SFZ-47-COOH), and its glucuronide conjugates. The metabolic profile was little different from that previously found in rabbits and dogs. CONCLUSION: The result demonstrates the usefulness of the fertilized chicken egg as a convenient source of both phase I and phase Ⅱ metabolites for further metabolism studies of SFZ-47.

  20. Increasing the durability of Li-ion batteries by means of manganese ion trapping materials with nitrogen functionalities

    Science.gov (United States)

    Banerjee, Anjan; Ziv, Baruch; Luski, Shalom; Aurbach, Doron; Halalay, Ion C.

    2017-02-01

    Manganese dissolution from positive electrodes seriously reduces the useful life of Li-ion batteries, especially with positive electrode materials having spinel phases. We show herein that Mn ion trapping separators containing inexpensive mass-produced materials may dramatically increase the life of Li-ion batteries. LiMn2O4-graphite cells containing these materials and a LiPF6 based electrolyte solution display excellent capacity retention during cycling at both room and elevated temperatures, over baseline cells with plain separators. After 30 days of cycling at 55 °C and C/5 rate, LiMn2O4-graphite cells containing three different Mn-trapping materials with nitrogen functionalities retain between 75% and 125% more of the initial capacity than the baseline cells. Mn amounts in graphite negative electrodes from cells with the functional separators are 13-21 times lower than in baseline cells. LiMn2O4 lattice shrinkage in cells with functionalized separators is negligible compared to baseline cells, indicating major reductions in the loss of electrochemically active Li+ ions and increased stability of the LiMn2O4 crystal lattice.

  1. Structural characterization of metabolites of the X-ray contrast agent iopromide in activated sludge using ion trap mass spectrometry.

    Science.gov (United States)

    Pérez, Sandra; Eichhorn, Peter; Celiz, Mary Dawn; Aga, Diana S

    2006-03-15

    Identification of degradation products of environmental contaminants is a challenging task because not only are they present in very low concentrations but they are also mixed with complex matrixes that interfere with detection. This work illustrates a simple approach using ion trap mass spectrometry combined with H/D-exchange experiments to elucidate the structures of iopromide metabolites formed during biodegradation in activated sludge. Iopromide is an X-ray contrast agent that has been detected frequently in effluents of wastewater treatment plants and in surface waters due to its persistence and high usage. Three metabolites produced by oxidation of the primary alcohols (forming carboxylates) on the side chains of iopromide were identified in a batch reactor with mixed liquor from a conventional activated sludge. Derivatization of the carboxylic acid to form a methyl ester and interpretation of the MS2 data of this derivative aided in the confirmation of the identities of these metabolites. Furthermore, one metabolite formed by dehydroxylation at the two side chains was identified in a batch reactor with mixed liquor from a nitrifying activated sludge. The MS2 fragmentation pattern of iopromide and its metabolites revealed that the iodinated ring remains intact and that minor transformations in the structure occur during biodegradation of iopromide in biological wastewater treatment plants.

  2. Evaluation of the site(s) of glycation in human proinsulin by ion-trap LCQ electrospray ionization mass spectrometry.

    Science.gov (United States)

    McKillop, Aine M; Meade, Angela; Flatt, Peter R; O'Harte, Finbarr P M

    2003-05-15

    The glycation of beta cell proteins is known to occur under hyperglycemic states. The site(s) of glycation in human proinsulin was investigated following exposure to a hyperglycemic environment under reducing conditions in vitro. Proinsulin and glycated proinsulin were separated by reversed-phase high-performance liquid chromatography (RP-HPLC) and identified using LCQ ion-trap electrospray ionization mass spectrometry. This revealed a major peak (>70% total) of monoglycated proinsulin (M(r) 9552.2 Da), a second peak (approximately 27%) of nonglycated proinsulin (M(r) 9389.8 Da), and a third minor peptide peak (approximately 3%) corresponding to diglycated proinsulin (M(r) 9717.9 Da). Following reduction of disulphide bridges with dithiothreitol, intact peptides were incubated with endoproteinase Glu-C to release nine daughter fragments for LC-MS analysis. This strategy revealed an N-terminal fragment of monoglycated proinsulin Phe(1)-Glu(13), which contained a single glucitol adduct (M(r) 1642.0 Da). A similar treatment of small amounts of purified diglycated proinsulin revealed a fragment with Phe(1)-Glu(13) linked by a disulphide bridge to Gln(70)-Glu(82) containing two glucitol adducts (M(r) 3292.7 Da). In summary, these studies indicate that the major site of glycation in proinsulin, like insulin, is the amino terminal Phe(1) residue. However, small amounts of diglycated proinsulin occur naturally, involving an additional site of glycation located between Gln(70) and Glu(82).

  3. Identification and quantification of active alkaloids in Catharanthus roseus by liquid chromatography-ion trap mass spectrometry.

    Science.gov (United States)

    Chen, Qinhua; Zhang, Wenpeng; Zhang, Yulin; Chen, Jing; Chen, Zilin

    2013-08-15

    Catharanthus roseus is an important dicotyledonous medicinal plant that produces anticancer compounds. The active alkaloids vinblastine, vindoline, ajmalicine, catharanthine, and vinleurosine were identified by direct-injection ion trap-mass spectrometry (IT-MS) for collecting MS(1-2) spectra. The determinations of five alkaloids were accomplished by liquid chromatography (LC) with UV and MS detections. The analytes provided good signals corresponding to the protonated molecular ions [M+H](+) and product ions. The precursor ions and product ions for quantification of vinblastine, vindoline, ajmalicine, catharanthine, and vinleurosine were m/z 825→807, 457→397, 353→144, 337→144 and 809→748 by LC-IT-MS, respectively. Two methods were used to evaluate a number of validation characteristics (repeatability, LOD, calibration range, and recovery). MS provided a high selectivity and sensitivity for determination of five alkaloids in positive mode. After optimisation of the methods, separation, identification and quantification of the five components in C. roseus were comprehensively accomplished by HPLC with UV and MS detection.

  4. Using Metal Complex Ion-Molecule Reactions in a Miniature Rectilinear Ion Trap Mass Spectrometer to Detect Chemical Warfare Agents

    Science.gov (United States)

    Graichen, Adam M.; Vachet, Richard W.

    2013-06-01

    The gas-phase reactions of a series of coordinatively unsaturated [Ni(L)n]y+ complexes, where L is a nitrogen-containing ligand, with chemical warfare agent (CWA) simulants in a miniature rectilinear ion trap mass spectrometer were investigated as part of a new approach to detect CWAs. Results show that upon entering the vacuum system via a poly(dimethylsiloxane) (PDMS) membrane introduction, low concentrations of several CWA simulants, including dipropyl sulfide (simulant for mustard gas), acetonitrile (simulant for the nerve agent tabun), and diethyl phosphite (simulant for nerve agents sarin, soman, tabun, and VX), can react with metal complex ions generated by electrospray ionization (ESI), thereby providing a sensitive means of detecting these compounds. The [Ni(L)n]2+ complexes are found to be particularly reactive with the simulants of mustard gas and tabun, allowing their detection at low parts-per-billion (ppb) levels. These detection limits are well below reported exposure limits for these CWAs, which indicates the applicability of this new approach, and are about two orders of magnitude lower than electron ionization detection limits on the same mass spectrometer. The use of coordinatively unsaturated metal complexes as reagent ions offers the possibility of further tuning the ion-molecule chemistry so that desired compounds can be detected selectively or at even lower concentrations.

  5. Investigation of the gas-phase hydrogen/deuterium exchange behavior of aromatic dicarboxylic acids in a quadrupole ion trap

    Science.gov (United States)

    Chipuk, Joseph E.; Brodbelt, Jennifer S.

    2007-11-01

    Gas-phase hydrogen/deuterium (H/D) exchange reactions of four deprotonated aromatic dicarboxylic acids (phthalic acid, isophthalic acid, terephthalic acid and 2,6-naphthalic acid) with D2O were performed in a quadrupole ion trap mass spectrometer. Experimental results showed significant differences in the rate and extent of exchange when the relative position of the carboxylic acid groups varied. Spontaneous and near complete exchange of one aromatic hydrogen atom occurred when the carboxylic acid groups were in the meta-position, whereas no additional exchange was observed for either the ortho- or para-isomers or for the structurally similar naphthalic acid. Computational investigations support the participation of several possible exchange mechanisms with the contribution of each relying heavily on the relative orientation of the acid moieties. A relay mechanism that bridges the deprotonation site and the labile hydrogen site appears to be responsible for the H/D exchange of not only the labile hydrogen atom of isophthalic acid, but also for the formation of a stable carbanion and corresponding subsequent exchange of one aromatic hydrogen atom. The impact of hydrogen bonding on the relay mechanism is demonstrated by the reaction of phthalic acid as the extent and rate of reaction are greatly retarded by the favorable interaction of the two carboxylic acid groups. Finally, a flip-flop mechanism is likely responsible for the exchange of both terephthalic acid and 2,6-naphthalic acid where the reactive sites are too remote for exchange via relay.

  6. Fast carbohydrate analysis via liquid chromatography coupled with ultra violet and electrospray ionization ion trap detection in 96-well format.

    Science.gov (United States)

    Rühmann, Broder; Schmid, Jochen; Sieber, Volker

    2014-07-11

    A fast carbohydrate screening platform processible in 96-well format is described. The method is suitable for the determination of various carbohydrates out of complex mixtures as obtained by acidic hydrolysis of carbohydrates polymers. The chromatographic conditions for an efficient separation (12min) and the derivatization process with 1-phenyl-3-methyl-5-pyrazolone (PMP) were optimized for high resolution separation and simultaneous determination of deoxy-, amino-, anhydro-sugars as well as hexoses, pentoses, dimers, uronic acids and degradation products like furfural and hydroxymethylfurfural (HMF). The potential to quantify with UV- and MS-detector in the same range has been demonstrated for 20 different compounds. Finally, the matrix effects of the hydrolysis were positively evaluated. The micro scale hydrolysis and PMP-derivatization without any extraction or drying steps, both in 96-well format, result in a fast and intuitive sample preparation. In combination with a fast liquid chromatography coupled to UV and electrospray ionization ion trap detection (LC-UV-ESI-MS/MS) for the qualification and quantification of various sugars, dimers and degradation products, this method shows great performance in carbohydrate analysis.

  7. Efficient modeling of plasma wakefield acceleration in quasi-non-linear-regimes with the hybrid code Architect

    Science.gov (United States)

    Marocchino, A.; Massimo, F.; Rossi, A. R.; Chiadroni, E.; Ferrario, M.

    2016-09-01

    In this paper we present a hybrid approach aiming to assess feasible plasma wakefield acceleration working points with reduced computation resources. The growing interest for plasma wakefield acceleration and especially the need to control with increasing precision the quality of the accelerated bunch demands for more accurate and faster simulations. Particle in cell codes are the state of the art technique to simulate the underlying physics, however the run-time represents the major drawback. Architect is a hybrid code that treats the bunch kinetically and the background electron plasma as a fluid, initialising bunches in vacuum so to take into account for the transition from vacuum to plasma. Architect solves directly the Maxwell's equations on a Yee lattice. Such an approach allows us to drastically reduce run time without loss of generality or accuracy up to the weakly non linear regime.

  8. Efficient modeling of plasma wakefield acceleration in quasi-non-linear-regimes with the hybrid code Architect

    Energy Technology Data Exchange (ETDEWEB)

    Marocchino, A., E-mail: albz.uk@gmail.com [Dipartimento SBAI, “Sapienza” University of Rome and INFN-Roma 1, Rome (Italy); Massimo, F. [Dipartimento SBAI, “Sapienza” University of Rome and INFN-Roma 1, Rome (Italy); Rossi, A.R. [Dipartimento di Fisica, University of Milan and INFN-Milano, Milano (Italy); Chiadroni, E.; Ferrario, M. [INFN-LNF, Frascati (Italy)

    2016-09-01

    In this paper we present a hybrid approach aiming to assess feasible plasma wakefield acceleration working points with reduced computation resources. The growing interest for plasma wakefield acceleration and especially the need to control with increasing precision the quality of the accelerated bunch demands for more accurate and faster simulations. Particle in cell codes are the state of the art technique to simulate the underlying physics, however the run-time represents the major drawback. Architect is a hybrid code that treats the bunch kinetically and the background electron plasma as a fluid, initialising bunches in vacuum so to take into account for the transition from vacuum to plasma. Architect solves directly the Maxwell's equations on a Yee lattice. Such an approach allows us to drastically reduce run time without loss of generality or accuracy up to the weakly non linear regime.

  9. A novel methodology for non-linear system identification of battery cells used in non-road hybrid electric vehicles

    Science.gov (United States)

    Unger, Johannes; Hametner, Christoph; Jakubek, Stefan; Quasthoff, Marcus

    2014-12-01

    An accurate state of charge (SoC) estimation of a traction battery in hybrid electric non-road vehicles, which possess higher dynamics and power densities than on-road vehicles, requires a precise battery cell terminal voltage model. This paper presents a novel methodology for non-linear system identification of battery cells to obtain precise battery models. The methodology comprises the architecture of local model networks (LMN) and optimal model based design of experiments (DoE). Three main novelties are proposed: 1) Optimal model based DoE, which aims to high dynamically excite the battery cells at load ranges frequently used in operation. 2) The integration of corresponding inputs in the LMN to regard the non-linearities SoC, relaxation, hysteresis as well as temperature effects. 3) Enhancements to the local linear model tree (LOLIMOT) construction algorithm, to achieve a physical appropriate interpretation of the LMN. The framework is applicable for different battery cell chemistries and different temperatures, and is real time capable, which is shown on an industrial PC. The accuracy of the obtained non-linear battery model is demonstrated on cells with different chemistries and temperatures. The results show significant improvement due to optimal experiment design and integration of the battery non-linearities within the LMN structure.

  10. ε-MAXIMUM PRINCIPLE IN LINEAR PROBLEM OF HYBRID SYSTEM OPTIMUM CONTROL

    Directory of Open Access Journals (Sweden)

    O. R. Gabasova

    2009-01-01

    Full Text Available The paper reveals necessary and sufficient conditions of optimality and sub-optimality of the programs for a hybrid system in the class of discrete control actions. The conditions are formulated in the support terms of  the initial problem. 

  11. Flavor release measurement by atmospheric pressure chemical ionization ion trap mass spectrometry, construction of interface and mathematical modeling of release profiles

    DEFF Research Database (Denmark)

    Haahr, Anne-Mette; Madsen, Henrik; Smedsgaard, Jørn

    2003-01-01

    An instrumental on-line retronasal flavor analysis was developed to obtain information about the release of flavor compounds in expired air from humans during eating. The volatile flavor compounds were measured by ion trap mass spectrometry with an atmospheric pressure chemical ionization source...... (APCI). An interface was designed to sample the breath directly from the nose. The repeat-ability in vitro for seven different flavor compounds came out with relative standard derivation less than 10% in most cases, which is acceptable. In vitro quantification was carried out by a determination...... of the concentration in the gas phase over a flavor solution by GC/MS, followed by measurements of intensities by the APCI ion trap. Ion suppression by acetone in the breath was negligible at concentration levels relevant in these experiments. The instrumental limits of detection for menthone and menthol coincide...

  12. Wavelet-based method for time-domain noise analysis and reduction in a frequency-scan ion trap mass spectrometer.

    Science.gov (United States)

    Chou, Szu-Wei; Shiu, Guo-Rung; Chang, Huan-Cheng; Peng, Wen-Ping

    2012-11-01

    We adopt an orthogonal wavelet packet decomposition (OWPD) filtering approach to cancel harmonic interference noises arising from an AC power source in time domain and remove the resulting rf voltage interference noise from the mass spectra acquired by using a charge detection frequency-scan quadrupole ion trap mass spectrometer. With the use of a phase lock resampling technique, the transform coefficients of the rf interference in signals become a constant, exhibiting a shift of the baseline in different rf phases. The rf interference is therefore removable by shifting the baselines back to zero in OWPD coefficients. The approach successfully reduces the time-domain background noise from 1367 electrons (rms) to 408 electrons (rms) (an improvement of 70 %) and removes the high frequency noise components in the charge detection ion trap mass spectrometry. Unlike other smoothing or averaging methods commonly used in the mass-to-charge (m/Ze) domain, our approach does not cause any distortion of original signals.

  13. Positive ion chemistry in the exhaust plumes of an air craft jet engine and a burner: investigations with a quadrupole ion trap mass spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Kiendler, A.; Aberle, S.; Arnold, F. [Max Planck Institute for Nuclear Physics, Heidelberg (Germany). Atmospheric Physics Div.

    2000-07-01

    Using a quadrupole ion trap mass spectrometer detailed composition analyses were made of positive ions in the exhaust of an aircraft jet engine and of a jet fuel burner. For both scenarios complex organic ions with large mass numbers were most abundant. By employing the MS{sup 2}-mode of the quadrupole ion trap mass spectrometer, mass selected trapped ions were intendently broken up and characteristic fragment ions were observed. The latter indicate that the parent ions contain hydrogen, carbon and oxygen which is indicative of oxygenated hydrocarbons. This contrasts recent composition measurements of negative ions in aircraft jet engine exhaust made by our group which revealed that negative ions contain the inorganic acid H{sub 2}SO{sub 4}. Our present measurements support the view that positive ions in aircraft jet engine exhaust contain preferably organic molecules. (author)

  14. Direct Analysis of Organic Compounds in Liquid Using a Miniature Photoionization Ion Trap Mass Spectrometer with Pulsed Carrier-Gas Capillary Inlet

    Science.gov (United States)

    Lu, Xinqiong; Yu, Quan; Zhang, Qian; Ni, Kai; Qian, Xiang; Tang, Fei; Wang, Xiaohao

    2017-08-01

    A miniature ion trap mass spectrometer with capillary direct sampling and vacuum ultraviolet photoionization source was developed to conduct trace analysis of organic compounds in liquids. Self-aspiration sampling is available where the samples are drawn into the vacuum chamber through a capillary with an extremely low flow rate (less than 1 μL/min), which minimizes sample consumption in each analysis to tens of micrograms. A pulsed gas-assisted inlet was designed and optimized to promote sample transmission in the tube and facilitate the cooling of ions, thereby improving instrument sensitivity. A limit of detection of 2 ppb could be achieved for 2,4-dimethylaniline in a methanol solution. The sampling system described in the present study is specifically suitable for a miniature photoionization ion trap mass spectrometer that can perform rapid and online analysis for liquid samples.

  15. Quantification of intermediate-abundance proteins in serum by multiple reaction monitoring mass spectrometry in a single-quadrupole ion trap.

    Science.gov (United States)

    Lin, Shanhua; Shaler, Thomas A; Becker, Christopher H

    2006-08-15

    A method is presented to quantify intermediate-abundance proteins in human serum using a single-quadrupole linear ion trap mass spectrometer-in contrast, for example, to a triple-quadrupole mass spectrometer. Stable-isotope-labeled (tryptic) peptides are spiked into digested protein samples as internal standards, aligned with the traditional isotope dilution approach. As a proof-of-concept experiment, four proteins of intermediate abundance were selected, coagulation factor V, adiponectin, C-reactive protein (CRP), and thyroxine binding globulin. Stable-isotope-labeled peptides were synthesized with one tryptic sequence from each of these proteins. The normal human serum concentration ranges of these proteins are from 1 to 30 microg/mL (or 20 to 650 pmol/mL). These labeled peptides and their endogenous counterparts were analyzed by LC-MS/MS using multiple reaction monitoring, a multiplexed form of the selected reaction monitoring technique. For these experiments, only one chromatographic dimension (on-line reversed-phase capillary column) was used. Improved limits of detection will result with multidimensional chromatographic methods utilizing more material per sample. Standard curves of the spiked calibrants were generated with concentrations ranging from 3 to 700 pmol/mL using both neat solutions and peptides spiked into the complex matrix of digested serum protein solution where ion suppression effects and interferences are common. Endogenous protein concentrations were determined by comparing MS/MS peak areas of the endogenous peptides to the isotopically labeled internal calibrants. The derived concentrations from a normal human serum pool (neglecting loss of material during sample processing) were 9.2, 110, 120, and 246 pmol/mL for coagulation factor V, adiponectin, CRP, and thyroxine binding globulin, respectively. These concentrations generally agree with the reported normal ranges for these proteins. As a measure of analytical reproducibility of this

  16. Quantitative determination of sotolon, maltol and free furaneol in wine by solid-phase extraction and gas chromatography-ion-trap mass spectrometry.

    Science.gov (United States)

    Ferreira, Vicente; Jarauta, Idoia; López, Ricardo; Cacho, Juan

    2003-08-22

    A method for the analytical determination of sotolon [4,5-dimethyl-3-hydroxy-2(5H)-furanone], maltol [3-hydroxy-2-methyl-4H-pyran-4-one] and free furaneol [2,5-dimethyl-4-hydroxy-3(2H)-furanone] in wine has been developed. The analytes are extracted from 50 ml of wine in a solid-phase extraction cartridge filled with 800 mg of LiChrolut EN resins. Interferences are removed with 15 ml of a pentane-dichloromethane (20:1) solution, and analytes are recovered with 6 ml of dichloromethane. The extract is concentrated up to 0.1 ml and analyzed by GC-ion trap MS. Maltol and sotolon were determined by selected ion storage of ions in the m/z ranges 120-153 and 79-95, using the ions m/z 126 and 83 for quantitation, respectively. Furaneol was determined by non-resonant fragmentation of the m/z 128 mother ion and subsequent analysis of the m/z 81 ion. The detection limits of the method are in all cases between 0.5 and 1 microg l(-1), well below the olfactory thresholds of the compounds. The precision of the method is in the 4-5% range for levels in wine around 20 microg l(-1). Linearity holds at least up to 400 microg l(-1), and is satisfactory in all cases. The recoveries of maltol and sotolon are constant (70 and 64%, respectively) and do not depend on the type of wine. On the contrary, in the case of furaneol, red wines show constant and high recoveries (97%), while the recoveries on white wines range between 30 and 80%. Different experiments showed that this behavior is probably due to the existence of complexes formed between furaneol and sulphur dioxide or catechols. Sensory experiments confirmed that the complexed forms found in white wines are not perceived by orthonasal olfaction, and that the furaneol determined by the method can be considered as the free and odor-active fraction.

  17. Ultraprecision XY stage using a hybrid bolt-clamped Langevin-type ultrasonic linear motor for continuous motion

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong-Jin; Lee, Sun-Kyu, E-mail: skyee@gist.ac.kr [School of Mechatronics, Gwangju Institute of Science and Technology, 123 Cheomdangwagi-ro, Buk-gu, Gwangju 500-712 (Korea, Republic of)

    2015-01-15

    This paper presents a design and control system for an XY stage driven by an ultrasonic linear motor. In this study, a hybrid bolt-clamped Langevin-type ultrasonic linear motor was manufactured and then operated at the resonance frequency of the third longitudinal and the sixth lateral modes. These two modes were matched through the preload adjustment and precisely tuned by the frequency matching method based on the impedance matching method with consideration of the different moving weights. The XY stage was evaluated in terms of position and circular motion. To achieve both fine and stable motion, the controller consisted of a nominal characteristics trajectory following (NCTF) control for continuous motion, dead zone compensation, and a switching controller based on the different NCTFs for the macro- and micro-dynamics regimes. The experimental results showed that the developed stage enables positioning and continuous motion with nanometer-level accuracy.

  18. Ion sponge: a 3-dimentional array of quadrupole ion traps for trapping and mass-selectively processing ions in gas phase.

    Science.gov (United States)

    Xu, Wei; Li, Linfan; Zhou, Xiaoyu; Ouyang, Zheng

    2014-05-01

    In this study, the concept of ion sponge has been explored for developing 3D arrays of large numbers of ion traps but with simple configurations. An ion sponge device with 484 trapping units in a volume of 10 × 10 × 3.2 cm has been constructed by simply stacking 9 meshes together. A single rf was used for trapping ions and mass-selective ion processing. The ion sponge provides a large trapping capacity and is highly transparent for transfer of ions, neutrals, and photons for gas phase ion processing. Multiple layers of quadrupole ion traps, with 121 trapping units in each layer, can operate as a single device for MS or MS/MS analysis, or as a series of mass-selective trapping devices with interlayer ion transfers facilitated by AC and DC voltages. Automatic sorting of ions to different trapping layers based on their mass-to-charge (m/z) ratios was achieved with traps of different sizes. Tandem-in-space MS/MS has also been demonstrated with precursor ions and fragment ions trapped in separate locations.

  19. Linear and nonlinear optics of hybrid plasmon-exciton nanomaterials in the presence of overlapping resonances

    CERN Document Server

    Sukharev, Maxim; Pachter, Ruth

    2015-01-01

    We consider a hybrid plasmon-exciton system comprised of a resonant molecular subsystem and three Au wires supporting a dipole mode which can be coupled to a dark mode in controllable fashion by variation of a symmetry parameter. The physics of such a system under strong coupling conditions is examined in detail. It is shown that if two wires supporting the dark mode are covered with molecular layers the system exhibits four resonant modes for a strong coupling regime due to asymmetry and lifted degeneracy of the molecular state in this case, while upon having molecular aggregates covering the top wire with dipolar mode, three resonant modes appear. Pump-probe simulations are performed to scrutinize the quantum dynamics and find possible ways to control plasmon-exciton materials. It is demonstrated that one can design hybrid nanomaterials with highly pronounced Fano-type resonances when excited by femtosecond lasers.

  20. A LINEAR-NEURAL HYBRID MODEL FOR ANALYSIS AND FORECASTING OF TIME-SERIES

    OpenAIRE

    MARCELO CUNHA MEDEIROS

    1998-01-01

    Esta dissertação apresenta um modelo não linear auto-regressivo com variáveis exógenas (ARX), para análise e previsão de séries temporais. Os coeficientes do modelo são estimados pela saída de uma rede neural feed-forward, treinada por um algoritmo híbrido de otimização. Os resultados obtidos são comparados tanto com modelos lineares, quanto com não lineares. This thesis presents a non linear autoregressive model with exogeneous variables (ARX), for time series analysis and forecasting. Th...

  1. Studying non-linearity of Mercury magnetosphere and solar wind interaction features using the combined hybrid model

    Science.gov (United States)

    Parunakian, David; Dyadechkin, Sergey; Alexeev, Igor; Belenkaya, Elena; Khodachenko, Maxim; Kallio, Esa; Alho, Markku

    2017-04-01

    The main focus of this work is to investigate non-linearity of Mercury's magnetospheric features. We use the paraboloid magnetospheric model (PMM) to calculate the initial magnetospheric field which we then use in hybrid simulations. We show that the initial total magnetospheric field can be considered a linear combination of the planetary dipole field, magnetospheric current system fields, and a penetrating portion of the interplanetary magnetic field (IMF). We use two sets of modelling runs with IMF values of identical magnitudes and anti-parallel directions. We then compute semi-sums and semi-differences of final magnetic field maps generated by hybrid plasma simulations, and use semi-sums to cancel out IMF contributions and semi-differences to cancel out PMM contributions. The remnant fields outside and inside the magnetosphere (for semi-sum and semi-difference fields, accordingly) are used to improve our ability to determine the position of the bow shock and magnetopause, as well as calculate the IMF penetration coefficient that results into best matches of this model to observational MESSENGER data. We compare Mercury's magnetosheath magnetic field predicted by our model with MESSENGER data in the appropriate orbit sections.

  2. A study of diagnostic x-ray lines in heliumlike neon using an electron beam ion trap

    Energy Technology Data Exchange (ETDEWEB)

    Wargelin, Bradford John [Univ. of California, Berkeley, CA (United States)

    1993-10-01

    Heliumlike ions play an extremely important role in X-ray astrophysics because of their emissivity and because the relative intensities of their emission lines can be used to infer physical characteristics of X-ray emitting plasmas, including temperature, electron density, and ionization balance. In order to properly apply these diagnostics, accurate atomic data are required, including cross sections for collisional excitation and ionization, radiative rates, and the wavelengths and strengths of satellite lines. Although theoretical atomic models have been created to estimate many of the rates and cross sections involved, very few experimental results are available for comparison with theoretical predictions. This thesis describes an experimental study of heliumlike neon using an electron beam ion trap, a device specifically designed to study X-ray emission from highly charged ions. Using a low-energy X-ray spectrometer designed and built for this experiment, electron impact excitation cross sections and dielectronic satellite strengths were measured for all significant n = 2→1 emission lines in He-like and Li-like Ne over a range of energy extending from well below the direct excitation threshold of the lines to over fourteen times the threshold energy. The cross section for innershell ionization of Li-like Ne, which excites the He-like forbidden line, was also measured. In addition, the radiative and collisional depopulation rates of the metastable ls2s 3S1, state, which form the basis of the He-like Ne density diagnostic, were determined. Experimental results were generally in agreement with theoretical predictions, although some significant differences were noted, particularly for the wavelengths and resonance strengths of dielectronic satellites.

  3. Evaluation and Quantitation of Intact Wax Esters of Human Meibum by Gas-Liquid Chromatography-Ion Trap Mass Spectrometry

    Science.gov (United States)

    Butovich, Igor A.; Arciniega, Juan C.; Lu, Hua; Molai, Mike

    2012-01-01

    Purpose. Wax esters (WE) of human meibum are one of the largest group of meibomian lipids. Their complete characterization on the level of individual intact lipid species has not been completed yet. We obtained detailed structural information on previously uncharacterized meibomian WE. Methods. Intact WE were separated and analyzed by means of high-temperature capillary gas-liquid chromatography (GLC) in combination with low voltage (30 eV) electron ionization ion trap mass spectrometry (ITMS). 3D (mass-to-charge ratio [m/z] versus lipid sample weight versus signal intensity) calibration plots were used for quantitation of WE. Results. We demonstrated that GLC-ITMS was suitable for analyzing unpooled/underivatized WE collected from 14 individual donors. More than 100 of saturated and unsaturated WE (SWE and UWE, respectively) were detected. On average, UWE represented about 82% of the total WE pool. About 90% of UWE were based on oleic acid, while less than 10% were based on palmitoleic acid. The amounts of poly-UWE were <3% of their mono-UWA counterparts. SWE were based primarily on C16–C18 fatty acids (FA) in overall molar ratios of 22:65:13. A pool of C16:0-FA was comprised of a 20:80 (mol/mol) mixture of straight chain and iso-branched isomers, while the corresponding ratio for C18:0-FA was 43:57. Interestingly, C17:0-FA was almost exclusively branched, with anteiso- and iso-isomers found in a ratio of 93:7. Conclusions. GLC-ITMS can be used successfully to analyze more than 100 individual species of meibomian WE, which were shown to comprise 41 ± 8% (wt/wt) of meibum, which made them the largest group of lipids in meibum. PMID:22531701

  4. Calibration of the OHREX high-resolution imaging crystal spectrometer at the Livermore electron beam ion traps

    Science.gov (United States)

    Hell, N.; Beiersdorfer, P.; Magee, E. W.; Brown, G. V.

    2016-11-01

    We report the calibration of the Orion High-Resolution X-ray (OHREX) imaging crystal spectrometer at the EBIT-I electron beam ion trap at Livermore. Two such instruments, dubbed OHREX-1 and OHREX-2, are fielded for plasma diagnostics at the Orion laser facility in the United Kingdom. The OHREX spectrometer can simultaneously house two spherically bent crystals with a radius of curvature of r = 67.2 cm. The focusing properties of the spectrometer allow both for larger distance to the source due to the increase in collected light and for observation of extended sources. OHREX is designed to cover a 2.5°-3° spectral range at Bragg angles around 51.3°. The typically high resolving powers at these large Bragg angles are ideally suited for line shape diagnostics. For instance, the nominal resolving power of the instrument (>10 000) is much higher than the effective resolving power associated with the Doppler broadening due to the temperature of the trapped ions in EBIT-I. The effective resolving power is only around 3000 at typical EBIT-I conditions, which nevertheless is sufficient to set up and test the instrument's spectral characteristics. We have calibrated the spectral range for a number of crystals using well known reference lines in the first and second order and derived the ion temperatures from these lines. We have also made use of the 50 μm size of the EBIT-I source width to characterize the spatial focusing of the spectrometer.

  5. Calibration of the OHREX high-resolution imaging crystal spectrometer at the Livermore electron beam ion traps

    Energy Technology Data Exchange (ETDEWEB)

    Hell, N. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Dr. Remeis-Sternwarte and ECAP, Universität Erlangen-Nürnberg, Bamberg 96049 (Germany); Beiersdorfer, P.; Magee, E. W.; Brown, G. V. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2016-11-15

    We report the calibration of the Orion High-Resolution X-ray (OHREX) imaging crystal spectrometer at the EBIT-I electron beam ion trap at Livermore. Two such instruments, dubbed OHREX-1 and OHREX-2, are fielded for plasma diagnostics at the Orion laser facility in the United Kingdom. The OHREX spectrometer can simultaneously house two spherically bent crystals with a radius of curvature of r = 67.2 cm. The focusing properties of the spectrometer allow both for larger distance to the source due to the increase in collected light and for observation of extended sources. OHREX is designed to cover a 2.5°–3° spectral range at Bragg angles around 51.3°. The typically high resolving powers at these large Bragg angles are ideally suited for line shape diagnostics. For instance, the nominal resolving power of the instrument (>10 000) is much higher than the effective resolving power associated with the Doppler broadening due to the temperature of the trapped ions in EBIT-I. The effective resolving power is only around 3000 at typical EBIT-I conditions, which nevertheless is sufficient to set up and test the instrument’s spectral characteristics. We have calibrated the spectral range for a number of crystals using well known reference lines in the first and second order and derived the ion temperatures from these lines. We have also made use of the 50 μm size of the EBIT-I source width to characterize the spatial focusing of the spectrometer.

  6. Multiresidue analysis of 50 pesticides in grape, pomegranate, and mango by gas chromatography-ion trap mass spectrometry.

    Science.gov (United States)

    Savant, Rahul H; Banerjee, Kaushik; Utture, Sagar C; Patil, Sangram H; Dasgupta, Soma; Ghaste, Manoj S; Adsule, Pandurang G

    2010-02-10

    A selective and sensitive multiresidue analysis method is reported for simultaneous determination of 50 pesticides of different chemical classes in three commercially important fruits of different nature viz. grape, pomegranate, and mango. The sample preparation method involves extraction of a 10 g sample with 10 mL of ethyl acetate; cleanup by dispersive solid phase extraction with primary secondary amine (PSA, 25 mg) for grape and PSA + graphitized carbon black (25 + 5 mg) for pomegranate and mango; and determination by gas chromatography-ion trap mass spectrometry through multiple reaction monitoring (MRM). Sample preparation under acidified (pH 4) and cold (<4 degrees C) conditions, use of PTV-large volume injection (20 microL) through multibaffled liner and chromatographic separation on a short 10 m VF-5MS capillary column gave a satisfactory response for all of the analytes including relatively unstable compounds such as captan, captafol, folpet, endrine, and iprodione within 31.8 min. The limit of quantification (LOQ) of most of the compounds was

  7. Thermally Accelerated Oxidative Degradation of Quercetin Using Continuous Flow Kinetic Electrospray-Ion Trap-Time of Flight Mass Spectrometry

    Science.gov (United States)

    Barnes, Jeremy S.; Foss, Frank W.; Schug, Kevin A.

    2013-10-01

    Thermally accelerated oxidative degradation of aqueous quercetin at pH 5.9 and 7.4 was kinetically measured using an in-house built online continuous flow device made of concentric capillary tubes, modified to fit to the inlet of an electrospray ionization-ion trap-time-of-flight-mass spectrometer (ESI-IT-TOF-MS). Time-resolved mass spectral measurements ranging from 2 to 21 min were performed in the negative mode to track intermediate degradation products and to evaluate the degradation rate of the deprotonated quercetin ion, [Q-H]-. Upon heating solutions in the presence of dissolved oxygen, degradation of [Q-H]- was observed and was accelerated by an increase in pH and temperature. Regardless of the condition, the same degradation pathways were observed. Degradation mechanisms and structures were determined using higher order tandem mass spectrometry (up to MS3) and high mass accuracy. The observed degradation mechanisms included oxidation, hydroxylation, and ring-cleavage by nucleophilic attack. A chalcan-trione structure formed by C-ring opening after hydroxylation at C2 was believed to be a precursor for other degradation products, formed by hydroxylation at the C2, C3, and C4 carbons from attack by nucleophilic species. This resulted in A-type and B-type ions after cross-ring cleavage of the C-ring. Based on time of appearance and signal intensity, nucleophilic attack at C3 was the preferred degradation pathway, which generated 2,4,6-trihydroxymandelate and 2,4,6-trihydroxyphenylglyoxylate ions. Overall, 23 quercetin-related ions were observed.

  8. Fragmentation pathways of synthetic and naturally occurring coumarin derivatives by ion trap and quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Liang, Xianrui; Han, Xiaomei

    2015-09-15

    Synthetic and natural coumarin derivatives possess a wide range of biological activities. Fragmentation pathway studies are important in identifying both naturally occurring coumarins and synthetic coumarins with novel structures and properties. The fragmentation pathways of eleven coumarin derivatives are investigated by electrospray ionization (ESI) ion-trap mass spectrometry (ESI-ITMS(n) ) and ESI quadrupole time-of-flight mass spectrometry (QTOFMS) in positive mode. Compounds 1-9 in this study were newly synthesized in our laboratory. Compounds 10 and 11 were isolated from the root of Zanthoxylum armatum. The major fragmentation pathways for 11 coumarin derivatives are greatly affected by the heterocyclic ring structures and the side-chain substituents. Typical losses of small neutral molecules, such as CH3 CH2 OH, CH2 =CH2 , CO, and H2 O, are observed for compounds 1-5. Compounds 6-9 share similar fragmentation pathways through losses of CO, aromatic rings, and the coumarin skeleton. The main product ions at m/z 205, 219, and 220 observed for compounds 10 and 11 are produced by the loss of C5 H12 O2 , C4 H10 O2 , and the C4 H9 O2 radical, respectively. The fragmentation pathways of 11 coumarin derivatives are elucidated based on ITMS(n) and QTOFMS spectral data. Differences in the structures of the heterocyclic rings and side-chain substituents strongly affect the fragmentation pathways of the coumarins. The present results will facilitate further research into the fragmentation pathways and structural characterization of these classes of compounds with diverse structures. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  9. A cylindrical quadrupole ion trap in combination with an electrospray ion source for gas-phase luminescence and absorption spectroscopy

    Science.gov (United States)

    Stockett, Mark H.; Houmøller, Jørgen; Støchkel, Kristian; Svendsen, Annette; Brøndsted Nielsen, Steen

    2016-05-01

    A relatively simple setup for collection and detection of light emitted from isolated photo-excited molecular ions has been constructed. It benefits from a high collection efficiency of photons, which is accomplished by using a cylindrical ion trap where one end-cap electrode is a mesh grid combined with an aspheric condenser lens. The geometry permits nearly 10% of the emitted light to be collected and, after transmission losses, approximately 5% to be delivered to the entrance of a grating spectrometer equipped with a detector array. The high collection efficiency enables the use of pulsed tunable lasers with low repetition rates (e.g., 20 Hz) instead of continuous wave (cw) lasers or very high repetition rate (e.g., MHz) lasers that are typically used as light sources for gas-phase fluorescence experiments on molecular ions. A hole has been drilled in the cylinder electrode so that a light pulse can interact with the ion cloud in the center of the trap. Simulations indicate that these modifications to the trap do not significantly affect the storage capability and the overall shape of the ion cloud. The overlap between the ion cloud and the laser light is basically 100%, and experimentally >50% of negatively charged chromophore ions are routinely photodepleted. The performance of the setup is illustrated based on fluorescence spectra of several laser dyes, and the quality of these spectra is comparable to those reported by other groups. Finally, by replacing the optical system with a channeltron detector, we demonstrate that the setup can also be used for gas-phase action spectroscopy where either depletion or fragmentation is monitored to provide an indirect measurement on the absorption spectrum of the ion.

  10. Multistage Fragmentation of Ion Trap Mass Spectrometry System and Pseudo-MS3 of Triple Quadrupole Mass Spectrometry Characterize Certain (E)-3-(Dimethylamino)-1-arylprop-2-en-1-ones: A Comparative Study

    OpenAIRE

    Ali S. Abdelhameed; Adnan A. Kadi; Abdel-Aziz, Hatem A.; Angawi, Rihab F.; Mohamed W. Attwa; Al-Rashood, Khalid A.

    2014-01-01

    A new approach was recently introduced to improve the structure elucidation power of tandem mass spectrometry simulating the MS3 of ion trap mass spectrometry system overcoming the different drawbacks of the latter. The fact that collision induced dissociation in the triple quadrupole mass spectrometer system provides richer fragment ions compared to those achieved in the ion trap mass spectrometer system utilizing resonance excitation. Moreover, extracting comprehensive spectra in the ion tr...

  11. Free chattering hybrid sliding mode control for a class of non-linear systems

    DEFF Research Database (Denmark)

    Khooban, Mohammad-Hassan; Niknam, Taher; Blaabjerg, Frede

    2016-01-01

    In current study, in order to find the control of general uncertain nonlinear systems, a new optimal hybrid control approach called Optimal General Type II Fuzzy Sliding Mode (OGT2FSM) is presented. In order to estimate unknown nonlinear activities in monitoring dynamic uncertainties, the benefits...... on the same topic, which are an Adaptive Interval Type-2 Fuzzy Logic Controller (AGT2FLC) and Conventional Sliding Mode Controller (CSMC), to assess the efficiency of the suggested controller. The suggested control scheme is finally used to the Electric Vehicles type as a case study. Results of simulation...

  12. Mixed-Integer-Linear-Programming-Based Energy Management System for Hybrid PV-Wind-Battery Microgrids

    DEFF Research Database (Denmark)

    Hernández, Adriana Carolina Luna; Aldana, Nelson Leonardo Diaz; Graells, Moises

    2017-01-01

    -side strategy, defined as a general mixed-integer linear programming by taking into account two stages for proper charging of the storage units. This model is considered as a deterministic problem that aims to minimize operating costs and promote self-consumption based on 24-hour ahead forecast data...

  13. Internal transport barrier triggered by non-linear lower hybrid wave deposition under condition of beam-driven toroidal rotation

    Science.gov (United States)

    Gao, Q. D.; Budny, R. V.

    2015-03-01

    By using gyro-Landau fluid transport model (GLF23), time-dependent integrated modeling is carried out using TRANSP to explore the dynamic process of internal transport barrier (ITB) formation in the neutral beam heating discharges. When the current profile is controlled by LHCD (lower hybrid current drive), with appropriate neutral beam injection, the nonlinear interplay between the transport determined gradients in the plasma temperature (Ti,e) and toroidal velocity (Vϕ) and the E×B flow shear (including q-profile) produces transport bifurcations, generating spontaneously a stepwise growing ITB. In the discharge, the constraints imposed by the wave propagation condition causes interplay of the LH driven current distribution with the plasma configuration modification, which constitutes non-linearity in the LH wave deposition. The non-linear effects cause bifurcation in LHCD, generating two distinct quasi-stationary reversed magnetic shear configurations. The change of current profile during the transition period between the two quasi-stationary states results in increase of the E×B shearing flow arising from toroidal rotation. The turbulence transport suppression by sheared E×B flow during the ITB development is analysed, and the temporal evolution of some parameters characterized the plasma confinement is examined. Ample evidence shows that onset of the ITB development is correlated with the enhancement of E×B shearing rate caused by the bifurcation in LHCD. It is suggested that the ITB triggering is associated with the non-linear effects of the LH power deposition.

  14. Optimal Design of Stochastic Distributed Order Linear SISO Systems Using Hybrid Spectral Method

    OpenAIRE

    2015-01-01

    The distributed order concept, which is a parallel connection of fractional order integrals and derivatives taken to the infinitesimal limit in delta order, has been the main focus in many engineering areas recently. On the other hand, there are few numerical methods available for analyzing distributed order systems, particularly under stochastic forcing. This paper proposes a novel numerical scheme for analyzing the behavior of a distributed order linear single input single output control s...

  15. Optimal design of stochastic distributed order linear SISO systems using hybrid spectral method

    OpenAIRE

    2015-01-01

    The distributed order concept, which is a parallel connection of fractional order integrals and derivatives taken to the infinitesimal limit in delta order, has been the main focus in many engineering areas recently. On the other hand, there are few numerical methods available for analyzing distributed order systems, particularly under stochastic forcing. This paper proposes a novel numerical scheme for analyzing the behavior of a distributed order linear single input single output control sy...

  16. A HYBRID TECHNIQUE FOR PAPR REDUCTION OF OFDM USING DHT PRECODING WITH PIECEWISE LINEAR COMPANDING

    Directory of Open Access Journals (Sweden)

    Thammana Ajay

    2016-06-01

    Full Text Available Orthogonal Frequency Division Multiplexing (OFDM is a fascinating approach for wireless communication applications which require huge amount of data rates. However, OFDM signal suffers from its large Peak-to-Average Power Ratio (PAPR, which results in significant distortion while passing through a nonlinear device, such as a transmitter high power amplifier (HPA. Due to this high PAPR, the complexity of HPA as well as DAC also increases. For the reduction of PAPR in OFDM many techniques are available. Among them companding is an attractive low complexity technique for the OFDM signal’s PAPR reduction. Recently, a piecewise linear companding technique is recommended aiming at minimizing companding distortion. In this paper, a collective piecewise linear companding approach with Discrete Hartley Transform (DHT method is expected to reduce peak-to-average of OFDM to a great extent. Simulation results shows that this new proposed method obtains significant PAPR reduction while maintaining improved performance in the Bit Error Rate (BER and Power Spectral Density (PSD compared to piecewise linear companding method.

  17. A study of tungsten spectra using large helical device and compact electron beam ion trap in NIFS

    Energy Technology Data Exchange (ETDEWEB)

    Morita, S.; Goto, M.; Murakami, I. [National Institute for Fusion Science, Toki 509-5292, Gifu (Japan); Department of Fusion Science, Graduate University for Advanced Studies, Toki 509-5292, Gifu (Japan); Dong, C. F.; Kato, D.; Sakaue, H. A.; Oishi, T. [National Institute for Fusion Science, Toki 509-5292, Gifu (Japan); Hasuo, M. [Department of Mechanical Engineering and Science, Graduate School of Engineering, Kyoto University, Kyoto 606-8501 (Japan); Koike, F. [Physics Laboratory, School of Medicine, Kitasato University, Sagamihara 252-0374 (Japan); Nakamura, N. [Institute of Laser Science, University of Electro-Communications, Tokyo 182-8585 (Japan); Sasaki, A. [Quantum Beam Science Directorate, Japan Atomic Energy Research Agency, Kizugawa 619-0215, Kyoto (Japan); Wang, E. H. [Department of Fusion Science, Graduate University for Advanced Studies, Toki 509-5292, Gifu (Japan)

    2013-07-11

    Tungsten spectra have been observed from Large Helical Device (LHD) and Compact electron Beam Ion Trap (CoBIT) in wavelength ranges of visible to EUV. The EUV spectra with unresolved transition array (UTA), e.g., 6g-4f, 5g-4f, 5f-4d and 5p-4d transitions for W{sup +24-+33}, measured from LHD plasmas are compared with those measured from CoBIT with monoenergetic electron beam ({<=}2keV). The tungsten spectra from LHD are well analyzed based on the knowledge from CoBIT tungsten spectra. The C-R model code has been developed to explain the UTA spectra in details. Radial profiles of EUV spectra from highly ionized tungsten ions have been measured and analyzed by impurity transport simulation code with ADPAK atomic database code to examine the ionization balance determined by ionization and recombination rate coefficients. As the first trial, analysis of the tungsten density in LHD plasmas is attempted from radial profile of Zn-like WXLV (W{sup 44+}) 4p-4s transition at 60.9A based on the emission rate coefficient calculated with HULLAC code. As a result, a total tungsten ion density of 3.5 Multiplication-Sign 10{sup 10}cm{sup -3} at the plasma center is reasonably obtained. In order to observe the spectra from tungsten ions in lower-ionized charge stages, which can give useful information on the tungsten influx in fusion plasmas, the ablation cloud of the impurity pellet is directly measured with visible spectroscopy. A lot of spectra from neutral and singly ionized tungsten are observed and some of them are identified. A magnetic forbidden line from highly ionized tungsten ions has been examined and Cd-like WXXVII (W{sup 26+}) at 3893.7A is identified as the ground-term fine-structure transition of 4f{sup 23}H{sub 5}-{sup 3}H{sub 4}. The possibility of {alpha} particle diagnostic in D-T burning plasmas using the magnetic forbidden line is discussed.

  18. Baseline toxicity and ion-trapping models to describe the pH-dependence of bacterial toxicity of pharmaceuticals.

    Science.gov (United States)

    Baumer, Andreas; Bittermann, Kai; Klüver, Nils; Escher, Beate I

    2017-07-19

    In numerous studies on the toxicity of ionisable organic chemicals, it has been shown that the toxicity was typically higher, when larger fractions of the neutral species were present. This observation was explained in some cases by slower uptake of charged species. In other cases it was suggested that the neutral species has intrinsically higher toxicity than the charged species or is alone responsible for the toxicity. However, even permanently charged and organic chemicals with multiple acid and base functional groups and zwitterions are toxic. We set out to reconcile the divergent views and to compare the various existing models for describing the pH-dependence of toxicity with the goal to derive one model that is valid independent of the type and number of charges on the molecule. To achieve this goal we measured the cytotoxicity of 18 acidic, 15 basic and 9 multiprotic/zwitterionic pharmaceuticals at pH 5.5 to pH 9 with the bioluminescence inhibition test using Aliivibrio fischeri (Microtox assay). This assay is useful for an evaluation of various models to describe pH-dependent toxicity because the majority of chemicals act as baseline toxicants in this 30 min cytotoxicity assay. Therefore baseline toxicity with constant membrane concentrations of the sum of all chemical species of approximately 200 mmol kglip(-1) served for the validation of the suitability of the various tested models. We confirmed that most tested pharmaceuticals acted as baseline toxicants in this assay at all examined pH values, when toxicity was modeled with a mixture model of concentration addition between the neutral species and all charged species. An ion trapping model, that assumes that the membrane permeability of charged species is kinetically limited, improved model predictions for some pharmaceuticals and pH values. However, neither unhindered uptake nor no uptake of the charged species were ideal models; the reality lies presumably between the two limiting cases with a slower

  19. Determination of the Na(+)/glucose cotransporter (SGLT1) turnover rate using the ion-trap technique.

    Science.gov (United States)

    Longpré, Jean-Philippe; Lapointe, Jean-Yves

    2011-01-05

    The Na(+)/glucose cotransporter (SGLT1) is a membrane protein that couples the transport of two Na(+) ions and one glucose molecule using the so-called alternating access mechanism. According to this principle, each cotransporter molecule can adopt either of two main conformations: one with the binding sites accessible to the extracellular solution and one with the binding sites facing the intracellular solution. The turnover rate (TOR) is the number of complete cycles that each protein performs per second. Determination of the TOR has important consequences for investigation of the cotransport mechanism, as none of the rate constants involved in mediating transport in a given direction (conformational changes and binding and unbinding reactions) can be slower than the TOR measured under the same conditions. In addition, the TOR can be used to estimate the number of cotransporter molecules involved in generating a given ensemble activity. In this study, we obtain an independent estimation of the TOR for human SGLT1 expressed in Xenopus laevis oocytes applying the ion-trap technique. This approach detects the quantity of ions released in or taken up from the restricted space existing between the oocyte plasma membrane and the tip of a large ion-selective electrode. Taking advantage of the fact that hSGLT1 in the absence of Na(+) can cotransport glucose with protons, we used a pH electrode to determine a TOR of 8.00 ± 1.3 s⁻¹ in the presence of 35 mM α-methyl-glucose at -150 mV (pH 5.5). For the same group of oocytes, a TOR of 13.3 ± 2.4 s⁻¹ was estimated under near-V(max) conditions, i.e., in the presence of 90 mM Na(+) and 5 mM α-methyl-glucose. Under these circumstances, the average cotransport current was -1.08 ± 0.61 μA (n = 14), and this activity was generated by an average of 3.6 ± 0.7 × 10¹¹ cotransporter molecules/oocyte. Copyright © 2011 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  20. Determination of the Na+/Glucose Cotransporter (SGLT1) Turnover Rate Using the Ion-Trap Technique

    Science.gov (United States)

    Longpré, Jean-Philippe; Lapointe, Jean-Yves

    2011-01-01

    The Na+/glucose cotransporter (SGLT1) is a membrane protein that couples the transport of two Na+ ions and one glucose molecule using the so-called alternating access mechanism. According to this principle, each cotransporter molecule can adopt either of two main conformations: one with the binding sites accessible to the extracellular solution and one with the binding sites facing the intracellular solution. The turnover rate (TOR) is the number of complete cycles that each protein performs per second. Determination of the TOR has important consequences for investigation of the cotransport mechanism, as none of the rate constants involved in mediating transport in a given direction (conformational changes and binding and unbinding reactions) can be slower than the TOR measured under the same conditions. In addition, the TOR can be used to estimate the number of cotransporter molecules involved in generating a given ensemble activity. In this study, we obtain an independent estimation of the TOR for human SGLT1 expressed in Xenopus laevis oocytes applying the ion-trap technique. This approach detects the quantity of ions released in or taken up from the restricted space existing between the oocyte plasma membrane and the tip of a large ion-selective electrode. Taking advantage of the fact that hSGLT1 in the absence of Na+ can cotransport glucose with protons, we used a pH electrode to determine a TOR of 8.00 ± 1.3 s−1 in the presence of 35 mM α-methyl-glucose at −150 mV (pH 5.5). For the same group of oocytes, a TOR of 13.3 ± 2.4 s−1 was estimated under near-Vmax conditions, i.e., in the presence of 90 mM Na+ and 5 mM α-methyl-glucose. Under these circumstances, the average cotransport current was −1.08 ± 0.61 μA (n = 14), and this activity was generated by an average of 3.6 ± 0.7 × 1011 cotransporter molecules/oocyte. PMID:21190656

  1. A study of tungsten spectra using large helical device and compact electron beam ion trap in NIFS

    Science.gov (United States)

    Morita, S.; Dong, C. F.; Goto, M.; Kato, D.; Murakami, I.; Sakaue, H. A.; Hasuo, M.; Koike, F.; Nakamura, N.; Oishi, T.; Sasaki, A.; Wang, E. H.

    2013-07-01

    Tungsten spectra have been observed from Large Helical Device (LHD) and Compact electron Beam Ion Trap (CoBIT) in wavelength ranges of visible to EUV. The EUV spectra with unresolved transition array (UTA), e.g., 6g-4f, 5g-4f, 5f-4d and 5p-4d transitions for W+24-+33, measured from LHD plasmas are compared with those measured from CoBIT with monoenergetic electron beam (≤2keV). The tungsten spectra from LHD are well analyzed based on the knowledge from CoBIT tungsten spectra. The C-R model code has been developed to explain the UTA spectra in details. Radial profiles of EUV spectra from highly ionized tungsten ions have been measured and analyzed by impurity transport simulation code with ADPAK atomic database code to examine the ionization balance determined by ionization and recombination rate coefficients. As the first trial, analysis of the tungsten density in LHD plasmas is attempted from radial profile of Zn-like WXLV (W44+) 4p-4s transition at 60.9Å based on the emission rate coefficient calculated with HULLAC code. As a result, a total tungsten ion density of 3.5×1010cm-3 at the plasma center is reasonably obtained. In order to observe the spectra from tungsten ions in lower-ionized charge stages, which can give useful information on the tungsten influx in fusion plasmas, the ablation cloud of the impurity pellet is directly measured with visible spectroscopy. A lot of spectra from neutral and singly ionized tungsten are observed and some of them are identified. A magnetic forbidden line from highly ionized tungsten ions has been examined and Cd-like WXXVII (W26+) at 3893.7Å is identified as the ground-term fine-structure transition of 4f23H5-3H4. The possibility of α particle diagnostic in D-T burning plasmas using the magnetic forbidden line is discussed.

  2. Oligo(ethylene glycol)-incorporated hybrid linear alkyl side chains for n-channel polymer semiconductors and their effect on the thin-film crystalline structure.

    Science.gov (United States)

    Kim, Ran; Kang, Boseok; Sin, Dong Hun; Choi, Hyun Ho; Kwon, Soon-Ki; Kim, Yun-Hi; Cho, Kilwon

    2015-01-28

    Oligo(ethylene glycol)-incorporated hybrid linear alkyl side chains, serving as solubilizing groups, are designed and introduced into naphthalene-diimide-based n-channel copolymers. The synthesized polymers exhibit unipolar n-type operation with an electron mobility of up to 1.64 cm(2) V(-1) s(-1), which demonstrates the usefulness of the hybrid side chains in polymer electronics applications.

  3. Micromotion Compensation and Photoionization of Ions in a Linear Trap

    Institute of Scientific and Technical Information of China (English)

    XIE Yi; ZHOU Fei; CHEN Liang; WAN Wei; FENG Mang

    2011-01-01

    @@ e confinement of ions in an electromagnetic trap is a prerequisite of sideband cooling and quantum information processing.For a string of ions in a linear ion trap,we report our recent efforts of compensating for micromotion of the ions by three methods,which yields narrower fluorescence spectra and lower temperature.We also achieve a photoionization scheme that loads the ions deterministically into the linear trap from an atomic beam.%The stable confinement of ions in an electromagnetic trap is a prerequisite of sideband cooling and quantum information processing. For a string of ions in a linear ion trap, we report our recent efforts of compensating for micromotion of the ions by three methods, which yields narrower fluorescence spectra and lower temperature. We also achieve a photoionization scheme that loads the ions deterministically into the linear trap from an atomic beam.

  4. Hybrid microscopy of human carotid atheroma by means of optical-resolution optoacoustic and non-linear optical microscopy

    Science.gov (United States)

    Seeger, Markus; Karlas, Angelos; Soliman, Dominik; Pelisek, Jaroslav; Ntziachristos, Vasilis

    2017-03-01

    Carotid atheromatosis is causally related to stroke, a leading cause of disability and death. We present the analysis of a human carotid atheroma using a novel hybrid microscopy system that combines optical-resolution optoacoustic (photoacoustic) microscopy and several non-linear optical microscopy modalities (second and third harmonic generation, as well as, two-photon excitation fluorescence) to achieve a multimodal examination of the extracted tissue within the same imaging framework. Our system enables the label-free investigation of atheromatous human carotid tissue with a resolution of about 1 μm and allows for the congruent interrogation of plaque morphology and clinically relevant constituents such as red blood cells, collagen, and elastin. Our data reveal mutual interactions between blood embeddings and connective tissue within the atheroma, offering comprehensive insights into its stage of evolution and severity, and potentially facilitating the further development of diagnostic tools, as well as treatment strategies.

  5. Evaluation Of Electrical And Thermal Performance Of A Linear Hybrid CPV-T Micro-Concentrator System

    Science.gov (United States)

    Everett, Vernie; Harvey, Judy; Surve, Sachin; Thomsen, Elizabeth; Walter, Daniel; Vivar, Marta; Blakers, Andrew; Tanner, Andrew; Greaves, Mikal; Le Leivre, Peter

    2011-12-01

    Chromasun Inc. and The Australian National University have developed a low-concentration, linear, hybrid micro-concentrator (MCT) system suitable for urban rooftop installation. The system produces both electrical and thermal power, integrating the functionality of separate flat plate photovoltaic and solar hot water systems. The MCT system utilises industry-standard components, including modified mono-crystalline silicon one-sun solar cells, commonly used in flat panel applications. The MCT manufacturing processes are designed around low-cost methods, and tap directly into existing economies of scale. Initial test results without any system optimisation has demonstrated an electrical output of more than 300 W, and a thermal output of more than 1500 W at 950 W/m2 DNI.

  6. Accurate localized resolution of identity approach for linear-scaling hybrid density functionals and for many-body perturbation theory

    Science.gov (United States)

    Ihrig, Arvid Conrad; Wieferink, Jürgen; Zhang, Igor Ying; Ropo, Matti; Ren, Xinguo; Rinke, Patrick; Scheffler, Matthias; Blum, Volker

    2015-09-01

    A key component in calculations of exchange and correlation energies is the Coulomb operator, which requires the evaluation of two-electron integrals. For localized basis sets, these four-center integrals are most efficiently evaluated with the resolution of identity (RI) technique, which expands basis-function products in an auxiliary basis. In this work we show the practical applicability of a localized RI-variant (‘RI-LVL’), which expands products of basis functions only in the subset of those auxiliary basis functions which are located at the same atoms as the basis functions. We demonstrate the accuracy of RI-LVL for Hartree-Fock calculations, for the PBE0 hybrid density functional, as well as for RPA and MP2 perturbation theory. Molecular test sets used include the S22 set of weakly interacting molecules, the G3 test set, as well as the G2-1 and BH76 test sets, and heavy elements including titanium dioxide, copper and gold clusters. Our RI-LVL implementation paves the way for linear-scaling RI-based hybrid functional calculations for large systems and for all-electron many-body perturbation theory with significantly reduced computational and memory cost.

  7. Linear benchmarks between the hybrid codes HYMAGYC and HMGC to study energetic particle driven Alfvénic modes

    Science.gov (United States)

    Fogaccia, G.; Vlad, G.; Briguglio, S.

    2016-11-01

    Resonant interaction between energetic particles (EPs), produced by fusion reactions and/or additional heating systems, and shear Alfvén modes can destabilize global Alfvénic modes enhancing the EP transport. In order to investigate the EP transport in present and next generation fusion devices, numerical simulations are recognized as a very important tool. Among the various numerical models, the hybrid MHD gyrokinetic one has shown to be a valid compromise between a sufficiently accurate wave-particle interaction description and affordable computational resource requirements. This paper presents a linear benchmark between the hybrid codes HYMAGYC and HMGC. The HYMAGYC code solves the full, linear MHD equations in general curvilinear geometry for the bulk plasma and describes the EP population by the nonlinear gyrokinetic Vlasov equation. On the other side, HMGC solves the nonlinear, reduced O≤ft(ε 03\\right) , pressureless MHD equations ({ε0} being the inverse aspect ratio) for the bulk plasma and the drift kinetic Vlasov equation for the EPs. The results of the HYMAGYC and HMGC codes have been compared both in the MHD limit and in a wide range of the EP parameter space for two test cases (one of which being the so-called TAE n  =  6 ITPA Energetic Particle Group test case), both characterized by {ε0}\\ll 1 . In the first test case (test case A), good qualitative agreement is found w.r.t. real frequencies, growth rates and spatial structures of the most unstable modes, with some quantitative differences for the growth rates. For the so-called ITPA test case (test case B), at the nominal energetic particle density value, the disagreement between the two codes is, on the contrary, also qualitative, as a different mode is found as the most unstable one.

  8. Mechanical Characterization of Hybrid Vesicles Based on Linear Poly(Dimethylsiloxane-b-Ethylene Oxide) and Poly(Butadiene-b-Ethylene Oxide) Block Copolymers.

    Science.gov (United States)

    Gaspard, Jeffery; Casey, Liam M; Rozin, Matt; Munoz-Pinto, Dany J; Silas, James A; Hahn, Mariah S

    2016-03-18

    Poly(dimethylsiloxane-ethylene oxide) (PDMS-PEO) and poly(butadiene-b-ethylene oxide) (PBd-PEO) are two block copolymers which separately form vesicles with disparate membrane permeabilities and fluidities. Thus, hybrid vesicles formed from both PDMS-PEO and PBd-PEO may ultimately allow for systematic, application-specific tuning of vesicle membrane fluidity and permeability. However, given the relatively low strength previously noted for comb-type PDMS-PEO vesicles, the mechanical robustness of the resulting hybrid vesicles must first be confirmed. Toward this end, we have characterized the mechanical behavior of vesicles formed from mixtures of linear PDMS-PEO and linear PBd-PEO using micropipette aspiration. Tension versus strain plots of pure PDMS12-PEO46 vesicles revealed a non-linear response in the high tension regime, in contrast to the approximately linear response of pure PBd33-PEO20 vesicles. Remarkably, the area expansion modulus, critical tension, and cohesive energy density of PDMS12-PEO46 vesicles were each significantly greater than for PBd33-PEO20 vesicles, although critical strain was not significantly different between these vesicle types. PDMS12-PEO46/PBd33-PEO20 hybrid vesicles generally displayed graded responses in between that of the pure component vesicles. Thus, the PDMS12-PEO46/PBd33-PEO20 hybrid vesicles retained or exceeded the strength and toughness characteristic of pure PBd-PEO vesicles, indicating that future assessment of the membrane permeability and fluidity of these hybrid vesicles may be warranted.

  9. Simultaneous determination of 24 or more acidic and alkaline phytohormones in femtomole quantities of plant tissues by high-performance liquid chromatography-electrospray ionization-ion trap mass spectrometry.

    Science.gov (United States)

    Liu, Shichang; Chen, Weiqi; Qu, Long; Gai, Ying; Jiang, Xiangning

    2013-02-01

    Phytohormones act at relatively low concentrations as major regulatory factors of plant growth and development, and cross talk of phytohormones is currently of great interest throughout the plant science community. To meet this demand, a method that is capable of simultaneously analyzing diverse plant hormones is essential. This paper introduces a high-performance liquid chromatographic separation technique coupled with sensitive and selective ion trap mass spectrometry to simultaneously determine 24 or more acidic and alkaline phytohormones, including auxin, cis- and trans-abscisic acid, 11 cytokinins, and 10 gibberellins, in a single injection of sample. A binary solid-phase extraction using Oasis MCX cartridges for cations and Oasis MAX cartridges for anions was used to prepurify more than 24 acidic and alkaline phytohormones from a single plant extract. The method showed good linearity for all 24 phytohormones with R(2) values ranging from 0.9903 to 0.9997. Limits of detection for most of the phytohormones were in the femtomole range with some extending into the sub-femtomole range. This method was applied to hundreds of plant samples comprising different tissues from various plants, including herbaceous, woody climbing, and woody plants to demonstrate feasibility and to validate the methodology.

  10. Simultaneous Qualitative and Quantitative Analysis of Multiple Chemical Constituents in YiQiFuMai Injection by Ultra-Fast Liquid Chromatography Coupled with Ion Trap Time-of-Flight Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Chunhua Liu

    2016-05-01

    Full Text Available YiQiFuMai injection (YQFM is a modern lyophilized powder preparation derived from the traditional Chinese medicine Sheng-mai san (SMS used for treating cardiovascular diseases, such as chronic heart failure. However, its chemical composition has not been fully elucidated, particularly for the preparation derived from Ophiopogon japonicus. This study aimed to establish a systematic and reliable method to quickly and simultaneously analyze the chemical constituents in YQFM by ultra-fast liquid chromatography coupled with ion trap time-of-flight mass spectrometry (UFLC-IT-TOF/MS. Sixty-five compounds in YQFM were tentatively identified by comparison with reference substances or literature data. Furthermore, twenty-one compounds, including three ophiopogonins, fifteen ginsenosides and three lignans were quantified by UFLC-IT-TOF/MS. Notably, this is the first determination of steroidal saponins from O. japonicus in YQFM. The relative standard deviations (RSDs of intra- and inter-day precision, reproducibility and stability were <4.9% and all analytes showed good linearity (R2 ≥ 0.9952 and acceptable recovery of 91.8%–104.2% (RSD ≤ 5.4%, indicating that the methods were reliable. These methods were successfully applied to quantitative analysis of ten batches of YQFM. The developed approach can provide useful and comprehensive information for quality control, further mechanistic studies in vivo and clinical application of YQFM.

  11. Application of gas phase cryogenic vibrational spectroscopy to characterize the CO2, CO, N2 and N2O interactions with the open coordination site on a Ni(I) macrocycle using dual cryogenic ion traps

    Science.gov (United States)

    Craig, Stephanie M.; Menges, Fabian S.; Johnson, Mark A.

    2017-02-01

    Recent advances in gas phase ion chemistry, coupled with cryogenic ion vibrational predissociation spectroscopy, provide a powerful way to characterize the structures of small molecules bound to open coordination sites of organometallic compounds. Here we extend our previous measurements on the relatively weakly interacting CO2 molecule with a Ni(I) tetraaza-macrocyclic compound to enable the characterization of more strongly interacting substrates. We first confirm the calculated η2-C,O binding motif of CO2 using isotopic labeling by direct, one photon vibrational predissociation of the Ni(I)-CO2 complex. We then apply this approach to study complexation of N2 at the active site. The generality of the method is then expanded to include application to more strongly bound systems that cannot be photodissociated with one IR photon. This involves implementation of a recently developed scheme (Marsh et al., 2015) involving two temperature-controlled ion traps. The first is optimized to complex the substrate molecule to the active site and the second is cooled to around 10 K to enable condensation of weakly bound "tag" molecules onto the target complex so as to enable its characterization by linear vibrational predissociation spectroscopy. We demonstrate this capability by applying it to the coordination of CO to the active Ni(I) site, as well as to elucidate the nature of the products that are formed upon reaction with N2O.

  12. Broadband Energy Harvester Using Non-linear Polymer Spring and Electromagnetic/Triboelectric Hybrid Mechanism

    Science.gov (United States)

    Gupta, Rahul Kumar; Shi, Qiongfeng; Dhakar, Lokesh; Wang, Tao; Heng, Chun Huat; Lee, Chengkuo

    2017-01-01

    Over the years, several approaches have been devised to widen the operating bandwidth, but most of them can only be triggered at high accelerations. In this work, we investigate a broadband energy harvester based on combination of non-linear stiffening effect and multimodal energy harvesting to obtain high bandwidth over wide range of accelerations (0.1 g–2.0 g). In order to achieve broadband behavior, a polymer based spring exhibiting multimodal energy harvesting is used. Besides, non-linear stiffening effect is introduced by using mechanical stoppers. At low accelerations (energy-harvesting, the obtained bandwidth increases from 23 Hz to 68 Hz with percentage increment of 295% at 1.8 g. Further, we have demonstrated the triboelectric output measured as acceleration sensing signals in terms of voltage and current sensitivity of 4.7 Vg−1 and 19.7 nAg−1, respectively. PMID:28120924

  13. Metabonomic Study of Biochemical Changes in Human Hair of Heroin Abusers by Liquid Chromatography Coupled with Ion Trap-Time of Flight Mass Spectrometry.

    Science.gov (United States)

    Xie, Pu; Wang, Tie-jie; Yin, Guo; Yan, Yan; Xiao, Li-he; Li, Qing; Bi, Kai-shun

    2016-01-01

    Hair analysis is with the advantage of non-invasive collection and long surveillance window. The present study employed a sensitive and reliable liquid chromatography coupled with ion trap-time of flight mass spectrometry method to study the metabonomic characters in the hair of 58 heroin abusers and 72 non-heroin abusers. Results indicated that certain endogenous metabolites, such as sorbitol and cortisol, were accelerated, and the level of arachidonic acid, glutathione, linoleic acid, and myristic acid was decreased in hair of heroin abusers. The metabonomic study is helpful for further understanding of heroin addiction and clinical diagnosis.

  14. Use of solid-phase microextraction for the detection of acetic acid by ion-trap gas chromatography-mass spectrometry and application to indoor levels in museums.

    Science.gov (United States)

    Godoi, Ana F L; Van Vaeck, Luc; Van Grieken, René

    2005-03-01

    A simple and efficient method using solid-phase microextraction (SPME) and gas chromatography-ion trap mass spectrometry (GC-ITMS) was developed for the analysis of acetic acid in air. The choice of the SPME fibre revealed to be critical as well as the sampling and desorption time. A dilution vessel was used for calibration. The precision of the method was found to be 4.7% relative standard deviation (RSD) and the detection limit 5.7 microg m(-3). The SPME-GC-MS technique was applied to the analysis of acetic acid in museum atmospheres.

  15. Hybrid Model Representation of a TLP Including Flexible Topsides in Non-Linear Regular Waves

    Directory of Open Access Journals (Sweden)

    Christof Wehmeyer

    2014-08-01

    Full Text Available The rising demand for renewable energy solutions is forcing the established industries to expand and continue evolving. For the wind energy sector, the vast resources in deep sea locations have encouraged research towards the installation of turbines in deeper waters. One of the most promising technologies able to solve this challenge is the floating wind turbine foundation. For the ultimate limit state, where higher order wave loads have a significant influence, a design tool that couples non-linear excitations with structural dynamics is required. To properly describe the behavior of such a structure, a numerical model is proposed and validated by physical test results. The model is applied to a case study of a tension leg platform with a flexible topside mimicking the tower and a lumped mass mimicking the rotor-nacelle assembly. The model is additionally compared to current commercial software, where the need for the coupled higher order dynamics proposed in this paper becomes evident.

  16. Internal transport barrier triggered by non-linear lower hybrid wave deposition under condition of beam-driven toroidal rotation

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Q. D., E-mail: qgao@swip.ac.cn [Southwestern Institute of Physics, Chengdu 610041 (China); Budny, R. V. [Princeton Plasma Physics Laboratory, Princeton University, Princeton, New Jersey 08543 (United States)

    2015-03-15

    By using gyro-Landau fluid transport model (GLF23), time-dependent integrated modeling is carried out using TRANSP to explore the dynamic process of internal transport barrier (ITB) formation in the neutral beam heating discharges. When the current profile is controlled by LHCD (lower hybrid current drive), with appropriate neutral beam injection, the nonlinear interplay between the transport determined gradients in the plasma temperature (T{sub i,e}) and toroidal velocity (V{sub ϕ}) and the E×B flow shear (including q-profile) produces transport bifurcations, generating spontaneously a stepwise growing ITB. In the discharge, the constraints imposed by the wave propagation condition causes interplay of the LH driven current distribution with the plasma configuration modification, which constitutes non-linearity in the LH wave deposition. The non-linear effects cause bifurcation in LHCD, generating two distinct quasi-stationary reversed magnetic shear configurations. The change of current profile during the transition period between the two quasi-stationary states results in increase of the E×B shearing flow arising from toroidal rotation. The turbulence transport suppression by sheared E×B flow during the ITB development is analysed, and the temporal evolution of some parameters characterized the plasma confinement is examined. Ample evidence shows that onset of the ITB development is correlated with the enhancement of E×B shearing rate caused by the bifurcation in LHCD. It is suggested that the ITB triggering is associated with the non-linear effects of the LH power deposition.

  17. Hybrid concept for the parameterization of the cascade of linear reservoirs for river flow routing using artificial neural networks

    Science.gov (United States)

    Úrek, Peter Å.; Szolgay, Jan; Čistý, Milan

    2010-05-01

    The lack of hydraulic and morphological data in many cases does not allow for using hydraulic methods for the simulation of the flood wave transformation between two river cross-sections. Under such conditions, as a rational alternative to hydraulic routing, hydrological routing models appear to be a suitable in the practice for flow forecasting. These models, beside numerical hydraulic models (and also models belonging to the class of non-storage routing methods), are in operational use in Slovakia. Usually, the morphological and hydraulic characteristics of the modelled river reaches and of the flow conditions are reflected in the routing model parameters, which are estimated by calibration and are kept constant for a given model during the simulation. In this contribution a new hybrid concept of model parameterization of the KLN model is presented. The KLN model is based on the state-space representation of the cascade of linear reservoirs. In the multilinear concept the travel-time parameter of the model was allowed to vary during simulation according to changing flow conditions. The model parameter changes in time according to an assumed relationship between the travel time of flood peaks and of selected characteristics of the flood wave. This relationship was estimated using artificial neural networks (ANN). In order to include all several possible effects, several setups of the ANN, which could possibly affect the model parameter, were tested. The ANN was trained to estimate the optimal values of model parameter and is used on- line during the routing procedure. The proposed hybrid concept is compared with other models used in practice.

  18. Multistage fragmentation of ion trap mass spectrometry system and pseudo-MS3 of triple quadrupole mass spectrometry characterize certain (E)-3-(dimethylamino)-1-arylprop-2-en-1-ones: a comparative study.

    Science.gov (United States)

    Abdelhameed, Ali S; Kadi, Adnan A; Abdel-Aziz, Hatem A; Angawi, Rihab F; Attwa, Mohamed W; Al-Rashood, Khalid A

    2014-01-01

    A new approach was recently introduced to improve the structure elucidation power of tandem mass spectrometry simulating the MS(3) of ion trap mass spectrometry system overcoming the different drawbacks of the latter. The fact that collision induced dissociation in the triple quadrupole mass spectrometer system provides richer fragment ions compared to those achieved in the ion trap mass spectrometer system utilizing resonance excitation. Moreover, extracting comprehensive spectra in the ion trap needs multistage fragmentation, whereas similar fragment ions may be acquired from one stage product ion scan using the triple quadrupole mass spectrometer. The new strategy was proven to enhance the qualitative performance of tandem mass spectrometry for structural elucidation of different chemical entities. In the current study we are endeavoring to prove our hypothesis of the efficiency of the new pseudo-MS(3) technique via its comparison with the MS(3) mode of ion trap mass spectrometry system. Ten pharmacologically and synthetically important (E)-3-(dimethylamino)-1-arylprop-2-en-1-ones (enaminones 4a-j) were chosen as model compounds for this study. This strategy permitted rigorous identification of all fragment ions using triple quadrupole mass spectrometer with sufficient specificity. It can be used to elucidate structures of different unknown components. The data presented in this paper provide clear evidence that our new pseudo-MS(3) may simulate the MS(3) of ion trap spectrometry system.

  19. Multistage Fragmentation of Ion Trap Mass Spectrometry System and Pseudo-MS3 of Triple Quadrupole Mass Spectrometry Characterize Certain (E-3-(Dimethylamino-1-arylprop-2-en-1-ones: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Ali S. Abdelhameed

    2014-01-01

    Full Text Available A new approach was recently introduced to improve the structure elucidation power of tandem mass spectrometry simulating the MS3 of ion trap mass spectrometry system overcoming the different drawbacks of the latter. The fact that collision induced dissociation in the triple quadrupole mass spectrometer system provides richer fragment ions compared to those achieved in the ion trap mass spectrometer system utilizing resonance excitation. Moreover, extracting comprehensive spectra in the ion trap needs multistage fragmentation, whereas similar fragment ions may be acquired from one stage product ion scan using the triple quadrupole mass spectrometer. The new strategy was proven to enhance the qualitative performance of tandem mass spectrometry for structural elucidation of different chemical entities. In the current study we are endeavoring to prove our hypothesis of the efficiency of the new pseudo-MS3 technique via its comparison with the MS3 mode of ion trap mass spectrometry system. Ten pharmacologically and synthetically important (E-3-(dimethylamino-1-arylprop-2-en-1-ones (enaminones 4a–j were chosen as model compounds for this study. This strategy permitted rigorous identification of all fragment ions using triple quadrupole mass spectrometer with sufficient specificity. It can be used to elucidate structures of different unknown components. The data presented in this paper provide clear evidence that our new pseudo-MS3 may simulate the MS3 of ion trap spectrometry system.

  20. Determination of the ReA Electron Beam Ion Trap electron beam radius and current density with an X-ray pinhole camera

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, Thomas M., E-mail: baumannt@nscl.msu.edu; Lapierre, Alain, E-mail: lapierre@nscl.msu.edu; Kittimanapun, Kritsada; Schwarz, Stefan; Leitner, Daniela; Bollen, Georg [National Superconducting Cyclotron Laboratory (NSCL), Michigan State University (MSU), 640 S. Shaw Lane, East Lansing, Michigan, 48824 (United States)

    2014-07-15

    The Electron Beam Ion Trap (EBIT) of the National Superconducting Cyclotron Laboratory at Michigan State University is used as a charge booster and injector for the currently commissioned rare isotope re-accelerator facility ReA. This EBIT charge breeder is equipped with a unique superconducting magnet configuration, a combination of a solenoid and a pair of Helmholtz coils, allowing for a direct observation of the ion cloud while maintaining the advantages of a long ion trapping region. The current density of its electron beam is a key factor for efficient capture and fast charge breeding of continuously injected, short-lived isotope beams. It depends on the radius of the magnetically compressed electron beam. This radius is measured by imaging the highly charged ion cloud trapped within the electron beam with a pinhole camera, which is sensitive to X-rays emitted by the ions with photon energies between 2 keV and 10 keV. The 80%-radius of a cylindrical 800 mA electron beam with an energy of 15 keV is determined to be r{sub 80%}=(212±19)μm in a 4 T magnetic field. From this, a current density of j = (454 ± 83)A/cm{sup 2} is derived. These results are in good agreement with electron beam trajectory simulations performed with TriComp and serve as a test for future electron gun design developments.

  1. Determination of non-ionic polyethoxylated surfactants in wastewater and river water by mixed hemimicelle extraction and liquid chromatography-ion trap mass spectrometry.

    Science.gov (United States)

    Cantero, Manuel; Rubio, Soledad; Pérez-Bendito, Dolores

    2005-03-04

    The capability of hemimicelles-based solid phase extraction (SPE)/liquid chromatography/atmospheric pressure chemical ionisation in positive mode, ion trap mass spectrometry (LC/(APCl+-IT)-MS) for the concentration, separation and quantitation of non-ionic surfactants has been investigated. Concentration was based on the formation of mixed aggregates of analytes [alkylphenol ethoxylates (APE, octyl and nonyl) and alkyl ethoxylates (AE, C12-C16)] with the anionic surfactant sodium dodecyl sulphate (SDS) that is adsorbed on alumina. Parameters affecting SPE were investigated on the basis that hemimicelles are dynamic entities in equilibrium with the aqueous phase. The performance of ion trap mass spectrometry for MS and MS/MS quantitation of non-ionic homologues was assessed. Recoveries of analytes from wastewater influent and effluent and river water samples ranged between 91 and 98% and were found independent on the length of the alkyl chain under the optimised conditions. Anionic surfactants did not interfere to the levels found in environmental samples. The detection limits ranged between 14 and 111 ng/l for wastewater influent, 10 and 40 for wastewater effluent and 4 and 35 for river water, after concentration of 250, 500 and 750 ml of sample, respectively. The approach was applied to the determination of AE and APE in influent and effluent samples from four wastewater treatment plants and four river samples. The concentrations of individual non-ionic surfactants found ranged between 0.3 and 373 microg/l.

  2. Accelerated solvent extraction followed by on-line solid-phase extraction coupled to ion trap LC/MS/MS for analysis of benzalkonium chlorides in sediment samples

    Science.gov (United States)

    Ferrer, I.; Furlong, E.T.

    2002-01-01

    Benzalkonium chlorides (BACs) were successfully extracted from sediment samples using a new methodology based on accelerated solvent extraction (ASE) followed by an on-line cleanup step. The BACs were detected by liquid chromatography/ion trap mass spectrometry (LC/MS) or tandem mass spectrometry (MS/MS) using an electrospray interface operated in the positive ion mode. This methodology combines the high efficiency of extraction provided by a pressurized fluid and the high sensitivity offered by the ion trap MS/MS. The effects of solvent type and ASE operational variables, such as temperature and pressure, were evaluated. After optimization, a mixture of acetonitrile/water (6:4 or 7:3) was found to be most efficient for extracting BACs from the sediment samples. Extraction recoveries ranged from 95 to 105% for C12 and C14 homologues, respectively. Total method recoveries from fortified sediment samples, using a cleanup step followed by ASE, were 85% for C12BAC and 79% for C14-BAC. The methodology developed in this work provides detection limits in the subnanogram per gram range. Concentrations of BAC homologues ranged from 22 to 206 ??g/kg in sediment samples from different river sites downstream from wastewater treatment plants. The high affinity of BACs for soil suggests that BACs preferentially concentrate in sediment rather than in water.

  3. Advanced stored waveform inverse Fourier transform technique for a matrix-assisted laser desorption/ionization quadrupole ion trap mass spectrometer.

    Science.gov (United States)

    Doroshenko, V M; Cotter, R J

    1996-01-01

    The stored waveform inverse Fourier transform (SWIFT) technique is used for broadband excitation of ions in an ion-trap mass spectrometer to perform mass-selective accumulation, isolation, and fragmentation of peptide ions formed by matrix-assisted laser desorption/ionization. Unit mass resolution is achieved for isolation of ions in the range of m/z up to 1300 using a two-step isolation technique with stretched-in-time narrow band SWIFT pulses at the second stage. The effect of 'stretched-in-time' waveforms is similar to that observed previously for mass-scan-rate reduction. The asymmetry phenomenon resulting from the stretched ion-trap electrode geometry is observed during application of normal and time-reversed waveforms and is similar to the asymmetry effects observed for forward and reverse mass scans in the resonance ejection mode. Mass-selective accumulation of ions from multiple laser shots was accomplished using a method described earlier that involves increasing the trapping voltage during ion introduction for more efficient trapping of ions.

  4. Sampling of organophosphorus pesticides at trace levels in the atmosphere using XAD-2 adsorbent and analysis by gas chromatography coupled with nitrogen-phosphorus and ion-trap mass spectrometry detectors.

    Science.gov (United States)

    Russo, Mario Vincenzo; Avino, Pasquale; Cinelli, Giuseppe; Notardonato, Ivan

    2012-09-01

    This paper shows an analytical methodology based on solid-phase extraction by XAD-2 adsorbent and gas chromatography (GC) coupled with nitrogen-phosphorus (NPD) and ion-trap mass spectrometry detectors (ITMS) in negative chemical ionization (NCI) mode analyses for investigating organophosphorus pesticides (OPs) at trace levels (in nanograms per cubic meter) in the atmosphere: in particular, we set up a procedure for analyzing 38 OPs. For the analytical methodology linearity responses have been obtained in GC-NPD (r > 0.9982) and GC-NCI/ITMS (r > 0.9974) in a large linearity range (0.10-500 pg μL(-1) in both cases) whereas the limits of detection range between 0.01 and 0.03 pg μL(-1) in both the techniques with a relative standard deviation (RSD) below 9.0 in both cases. Particular attention has been devoted to investigate the effect of different solvents (n-hexane, benzene, chloroform, carbon disulfide, acetonitrile) on the OP recovery as well the breakthrough volumes have been evaluated (100% recovery up to 4,286 L g(-1)). The study has also investigated the OP recoveries at different sampling flow rates (1.5 and 2.0 L min(-1)) for determining the optimal conditions for sample collection. Finally, the whole approach has been successfully applied to real samples collected in four different areas in the Molise region (Central Italy) during different seasons: the results show that parathion-ethyl, dimethoate, omethoate, and malathion are present in all periods at low levels (ranging between 70 and 10 ng m(-3)): their levels in such periods can be correlated with spraying as well atmospheric conditions favoring the dispersion/accumulation of these pollutants.

  5. Incorporated W Roles on Microstructure and Properties of W-C:H Films by a Hybrid Linear Ion Beam Systems

    Directory of Open Access Journals (Sweden)

    Peng Guo

    2013-01-01

    Full Text Available W-incorporated diamond-like carbon (W-C:H films were fabricated by a hybrid beams system consisting of a DC magnetron sputtering and a linear ion source. The W concentration (1.08~31.74 at.% in the film was controlled by varying the sputtering current. The cross-sectional topography, composition, and microstructure of the W-C:H films were investigated by SEM, XPS, TEM, and Raman spectroscopy. The mechanical and tribological properties of the films as a function of W concentration were evaluated by a stress-tester, nanoindentation, and ball-on-disk tribometer, respectively. The results showed that films mainly exhibited the feature of amorphous carbon when W concentration of the films was less than 4.38 at.%, where the incorporated W atoms would be bonded with C atoms and resulted in the formation of WC1-x nanoparticles. The W-C:H film with 4.38 at.% W concentration showed a minimum value of residual compressive stress, a higher hardness, and better tribological properties. Beyond this W concentration range, both the residual stress and mechanical properties were deteriorated due to the growth of tungsten carbide nanoparticles in the carbon matrix.

  6. Crude oil price forecasting based on hybridizing wavelet multiple linear regression model, particle swarm optimization techniques, and principal component analysis.

    Science.gov (United States)

    Shabri, Ani; Samsudin, Ruhaidah

    2014-01-01

    Crude oil prices do play significant role in the global economy and are a key input into option pricing formulas, portfolio allocation, and risk measurement. In this paper, a hybrid model integrating wavelet and multiple linear regressions (MLR) is proposed for crude oil price forecasting. In this model, Mallat wavelet transform is first selected to decompose an original time series into several subseries with different scale. Then, the principal component analysis (PCA) is used in processing subseries data in MLR for crude oil price forecasting. The particle swarm optimization (PSO) is used to adopt the optimal parameters of the MLR model. To assess the effectiveness of this model, daily crude oil market, West Texas Intermediate (WTI), has been used as the case study. Time series prediction capability performance of the WMLR model is compared with the MLR, ARIMA, and GARCH models using various statistics measures. The experimental results show that the proposed model outperforms the individual models in forecasting of the crude oil prices series.

  7. Crude Oil Price Forecasting Based on Hybridizing Wavelet Multiple Linear Regression Model, Particle Swarm Optimization Techniques, and Principal Component Analysis

    Directory of Open Access Journals (Sweden)

    Ani Shabri

    2014-01-01

    Full Text Available Crude oil prices do play significant role in the global economy and are a key input into option pricing formulas, portfolio allocation, and risk measurement. In this paper, a hybrid model integrating wavelet and multiple linear regressions (MLR is proposed for crude oil price forecasting. In this model, Mallat wavelet transform is first selected to decompose an original time series into several subseries with different scale. Then, the principal component analysis (PCA is used in processing subseries data in MLR for crude oil price forecasting. The particle swarm optimization (PSO is used to adopt the optimal parameters of the MLR model. To assess the effectiveness of this model, daily crude oil market, West Texas Intermediate (WTI, has been used as the case study. Time series prediction capability performance of the WMLR model is compared with the MLR, ARIMA, and GARCH models using various statistics measures. The experimental results show that the proposed model outperforms the individual models in forecasting of the crude oil prices series.

  8. Mechanical Characterization of Hybrid Vesicles Based on Linear Poly(Dimethylsiloxane-b-Ethylene Oxide and Poly(Butadiene-b-Ethylene Oxide Block Copolymers

    Directory of Open Access Journals (Sweden)

    Jeffery Gaspard

    2016-03-01

    Full Text Available Poly(dimethylsiloxane-ethylene oxide (PDMS-PEO and poly(butadiene-b-ethylene oxide (PBd-PEO are two block copolymers which separately form vesicles with disparate membrane permeabilities and fluidities. Thus, hybrid vesicles formed from both PDMS-PEO and PBd-PEO may ultimately allow for systematic, application-specific tuning of vesicle membrane fluidity and permeability. However, given the relatively low strength previously noted for comb-type PDMS-PEO vesicles, the mechanical robustness of the resulting hybrid vesicles must first be confirmed. Toward this end, we have characterized the mechanical behavior of vesicles formed from mixtures of linear PDMS-PEO and linear PBd-PEO using micropipette aspiration. Tension versus strain plots of pure PDMS12-PEO46 vesicles revealed a non-linear response in the high tension regime, in contrast to the approximately linear response of pure PBd33-PEO20 vesicles. Remarkably, the area expansion modulus, critical tension, and cohesive energy density of PDMS12-PEO46 vesicles were each significantly greater than for PBd33-PEO20 vesicles, although critical strain was not significantly different between these vesicle types. PDMS12-PEO46/PBd33-PEO20 hybrid vesicles generally displayed graded responses in between that of the pure component vesicles. Thus, the PDMS12-PEO46/PBd33-PEO20 hybrid vesicles retained or exceeded the strength and toughness characteristic of pure PBd-PEO vesicles, indicating that future assessment of the membrane permeability and fluidity of these hybrid vesicles may be warranted.

  9. Analysis of the fine structure of Sn11 +-Sn14 + ions by optical spectroscopy in an electron-beam ion trap

    Science.gov (United States)

    Windberger, A.; Torretti, F.; Borschevsky, A.; Ryabtsev, A.; Dobrodey, S.; Bekker, H.; Eliav, E.; Kaldor, U.; Ubachs, W.; Hoekstra, R.; Crespo López-Urrutia, J. R.; Versolato, O. O.

    2016-07-01

    We experimentally re-evaluate the fine structure of Sn11 +-Sn14 + ions. These ions are essential in bright extreme-ultraviolet (EUV) plasma-light sources for next-generation nanolithography, but their complex electronic structure is an open challenge for both theory and experiment. We combine optical spectroscopy of magnetic dipole M 1 transitions, in a wavelength range covering 260 to 780 nm, with charge-state selective ionization in an electron beam ion trap. Our measurements confirm the predictive power of ab initio calculations based on Fock space coupled cluster theory. We validate our line identification using semiempirical cowan calculations with adjustable wave-function parameters. Available Ritz combinations further strengthen our analysis. Comparison with previous work suggests that line identifications in the EUV need to be revisited.

  10. Determination of specific neuropeptides modulation time course in a rat model of osteoarthritis pain by liquid chromatography ion trap mass spectrometry.

    Science.gov (United States)

    Ferland, Catherine E; Pailleux, Floriane; Vachon, Pascal; Beaudry, Francis

    2011-12-01

    Animal models are useful to evaluate pharmacological therapies to alleviate joint pain. The present study characterized central neuropeptides modulation in the monoiodoacetate (MIA) rat model. Animals receiving a single 3mg MIA injection were euthanized at 3, 7, 14, 21 and 28 days post injection. Spinal cords were analyzed by liquid chromatography ion trap mass spectrometry. Up-regulations of the calcitonin gene-related peptide and substance P were observed starting on days 7 and 28 respectively, whereas big dynorphin(₁₋₃₂) content decreased significantly on day 14 in comparison to control animals (P<0.05). Preclinical drug evaluations using this model should be conducted between 7 and 21 days post injection when the lesions resemble most to human osteoarthritis.

  11. Structural elucidation of biologically active neomycin N-octyl derivatives in a regioisomeric mixture by means of liquid chromatography/ion trap time-of-flight mass spectrometry.

    Science.gov (United States)

    Giera, Martin; de Vlieger, Jon S B; Lingeman, Henk; Irth, Hubertus; Niessen, Wilfried M A

    2010-05-30

    Structural elucidation of six regioisomers of mono-N-octyl derivatized neomycin is achieved using MS(n) (up to n = 4) on an ion trap time-of-flight (IT-TOF) instrument equipped with electrospray ionization. The mixture of six derivatized neomycin analogues was generated by reductive amination in a shotgun synthetic approach. In parallel to the liquid chromatography/mass spectrometry (LC/MS) detection, the antibacterial activity of the neomycin regioisomers was tested by post-column addition of buffer and bacterial inocula, subsequent microfractionation of the resulting mixture, incubation, and finally a chemiluminescence-based bioactivity measurement based on the production of bacterial ATP. The MS-based high-resolution screening approach described can be applied in medicinal chemistry to help in designing and producing new antibiotic substances, which is particularly challenging due to the high functionality of most antibiotic substances, therefore requiring advanced (hyphenated) separation and detection techniques for compound mixtures.

  12. Methanol chemical ionization quadrupole ion trap mass spectrometry of O-ethyl S-[2-(diisopropylamino)ethyl] methylphosphonothiolate (VX) and its degradation products.

    Science.gov (United States)

    Rohrbaugh, D K

    2000-10-06

    Mass spectrometric analysis of O-ethyl S-[2-(diisopropylamino)ethyl] methylphosphonothiolate (VX) degradation products by electron ionization produces extensive fragmentation with little or no molecular ion information making product identification difficult. Milder chemical ionization (CI) is commonly used to provide molecular mass and structure confirmation. In this study, methanol was used as a CI reagent in combination with an ion trap detector for detection and identification of over 30 compounds present in a thermally degraded sample of VX. The use of methanol provides superior results for this class of compounds with less fragmentation than commonly observed with gas reagents and offers logistical advantages for on-site analysis by being easier to transport and safer to use than gas cylinders.

  13. Direct observation of high-spin states in manganese dimer and trimer cations by x-ray magnetic circular dichroism spectroscopy in an ion trap

    Energy Technology Data Exchange (ETDEWEB)

    Zamudio-Bayer, V. [Physikalisches Institut, Universität Freiburg, Stefan-Meier-Straße 21, 79104 Freiburg (Germany); Institut für Methoden und Instrumentierung der Forschung mit Synchrotronstrahlung, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Albert-Einstein-Straße 15, 12489 Berlin (Germany); Hirsch, K.; Langenberg, A.; Kossick, M. [Institut für Methoden und Instrumentierung der Forschung mit Synchrotronstrahlung, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Albert-Einstein-Straße 15, 12489 Berlin (Germany); Institut für Optik und Atomare Physik, Technische Universität Berlin, Hardenbergstraße 36, 10623 Berlin (Germany); Ławicki, A.; Lau, J. T., E-mail: tobias.lau@helmholtz-berlin.de [Institut für Methoden und Instrumentierung der Forschung mit Synchrotronstrahlung, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Albert-Einstein-Straße 15, 12489 Berlin (Germany); Terasaki, A. [Cluster Research Laboratory, Toyota Technological Institute, 717-86 Futamata, Ichikawa, Chiba 272-0001 (Japan); Department of Chemistry, Kyushu University, 6-10-1 Hakozaki, Higashi-ku, Fukuoka 812-8581 (Japan); Issendorff, B. von [Physikalisches Institut, Universität Freiburg, Stefan-Meier-Straße 21, 79104 Freiburg (Germany)

    2015-06-21

    The electronic structure and magnetic moments of free Mn{sub 2}{sup +} and Mn{sub 3}{sup +} are characterized by 2p x-ray absorption and x-ray magnetic circular dichroism spectroscopy in a cryogenic ion trap that is coupled to a synchrotron radiation beamline. Our results directly show that localized magnetic moments of 5 μ{sub B} are created by 3d{sup 5}({sup 6}S) states at each ionic core, which are coupled ferromagnetically to form molecular high-spin states via indirect exchange that is mediated in both cases by a delocalized valence electron in a singly occupied 4s derived antibonding molecular orbital with an unpaired spin. This leads to total magnetic moments of 11 μ{sub B} for Mn{sub 2}{sup +} and 16 μ{sub B} for Mn{sub 3}{sup +}, with no contribution of orbital angular momentum.

  14. Electrospray Ionization/Ion Mobility Spectrometer/Cylindrical Ion Trap Mass Spectrometer System for In-Situ Detection of Organic Compounds

    Science.gov (United States)

    Kanik, I.; Johnson, P. V.; Beegle, L. W.; Cooks, R. G.; Laughlin, B. C.; Hill, H. H.

    2003-01-01

    The potential of an Electrospray Ionization/Ion Mobility Spectrometer/Cylindrical Ion Trap Mass Spectrometer (ESI/IMS/CIT-MS) as an analytical instrument for analyzing material extracted from rock and soil samples as part of a suite of instruments on the proposed 2009 Mars Science Lander (MSL) will be demonstrated. This instrument will be able to identify volatile compounds as well as resident organic molecules on the parts-per-billion (ppb) level. Also, it will be able to obtain an inventory of chemical species on the surface of Mars which will result in a better understanding of ongoing surface chemistry. Finally, questions relevant to biological processes will be answered with the complete inventory of surface and near surface organic molecules that the ESI/IMS/CIT is capable of performing.

  15. A preliminary study of arecoline and guvacoline presence in the saliva of a "betel-quid" chewer using liquid-chromatography ion trap mass spectrometry.

    Science.gov (United States)

    Kadi, Adnan A; Attwa, Mohamed W; Rahman, A F M Motiur

    2013-01-01

    It has been reported that the parasympathomimetic alkaloid arecoline and the nootropic agent guvacoline have been detected in areca nut (Areca catechu L.) during extraction using a basic medium. Here, we have studied the detection of arecoline and guvacoline in vivo in saliva of a "betel-quid" chewer using liquid-chromatography ion trap mass spectrometry. In this paper, we provide evidence that guvacoline is absent in the neutral aqueous extract of betel nut, but is present in abundance in the aqueous extract with added time (pH 11.9). In an in vivo experiment, we demonstrated that guvacoline is present in the salivary extracts in the mouth with time (pH 9.5) and without lime (pH5.3).

  16. Resonance activation and collision-induced-dissociation of ions using rectangular wave dipolar potentials in a digital ion trap mass spectrometer.

    Science.gov (United States)

    Xu, Fuxing; Wang, Liang; Dai, Xinhua; Fang, Xiang; Ding, Chuan-Fan

    2014-04-01

    Collision-induced dissociation (CID) of ions by resonance activation in a quadrupole ion trap is usually accomplished by resonance exciting the ions to higher kinetic energy, whereby the high kinetic energy ions collide with a bath gas, such as helium or argon, inside the trap and dissociate to fragments. A new ion activation method using a well-defined rectangular wave dipolar potential formed by dividing down the trapping rectangular waveform is developed and examined herein. The mass-selected parent ions are resonance excited to high kinetic energies by simply changing the frequency of the rectangular wave dipolar potential and dissociation proceeds. A relationship between the ion mass and the activation waveform frequency is also identified and described. This highly efficient (CID) procedure can be realized by simply changing the waveform frequency of the dipolar potential, which could certainly simplify tandem mass spectrometry analysis methods.

  17. Development and validation of automatic HS-SPME with a gas chromatography-ion trap/mass spectrometry method for analysis of volatiles in wines.

    Science.gov (United States)

    Paula Barros, Elisabete; Moreira, Nathalie; Elias Pereira, Giuliano; Leite, Selma Gomes Ferreira; Moraes Rezende, Claudia; Guedes de Pinho, Paula

    2012-11-15

    An automated headspace solid-phase microextraction (HS-SPME) combined with gas chromatography-ion trap/mass spectrometry (GC-IT/MS) was developed in order to quantify a large number of volatile compounds in wines such as alcohols, ester, norisoprenoids and terpenes. The procedures were optimized for SPME fiber selection, pre-incubation temperature and time, extraction temperature and time, and salt addition. A central composite experimental design was used in the optimization of the extraction conditions. The volatile compounds showed optimal extraction using a DVB/CAR/PDMS fiber, incubation of 5 ml of wine with 2g NaCl at 45 °C during 5 min, and subsequent extraction of 30 min at the same temperature. The method allowed the identification of 64 volatile compounds. Afterwards, the method was validated successfully for the most significant compounds and was applied to study the volatile composition of different white wines.

  18. Spectra of W19 +-W32 + observed in the EUV region between 15 and 55 Å with an electron-beam ion trap

    Science.gov (United States)

    Sakaue, H. A.; Kato, D.; Yamamoto, N.; Nakamura, N.; Murakami, I.

    2015-07-01

    We present extreme ultraviolet spectra of highly charged tungsten ions (W19 +-W32 + ) in the wavelength range of 15 -55 Å obtained with a compact electron-beam ion trap (CoBIT) and a grazing-incidence spectrometer at the National Institute for Fusion Science. The electron energy dependence of the spectra was investigated for electron energies from 490 to 1320 eV . Identification of the observed lines was aided by collisional-radiative (CR) modeling of CoBIT plasma. Good quantitative agreement was obtained between the CR-modeling results and the experimental observations. The ion charge dependence of the 6 g -4 f ,5 g -4 f ,5 f -4 d ,5 p -4 d , and 4 f -4 d transition wavelengths were measured.

  19. Direct Observation of High-Spin States in Manganese Dimer and Trimer Cations by X-ray Magnetic Circular Dichroism Spectroscopy in an Ion Trap

    CERN Document Server

    Zamudio-Bayer, Vicente; Langenberg, Andreas; Kossick, Martin; Ławicki, Arkadiusz; Terasaki, Akira; von Issendorff, Bernd; Lau, J Tobias

    2015-01-01

    The electronic structure and magnetic moments of free Mn$_2^+$ and Mn$_3^+$ are characterized by $2p$ x-ray absorption and x-ray magnetic circular dichroism spectroscopy in a cryogenic ion trap that is coupled to a synchrotron radiation beamline. Our results show directly that localized magnetic moments of 5 $\\mu_B$ are created by $3d^5 (^6\\mathrm{S})$ states at each ionic core, which are coupled in parallel to form molecular high-spin states via indirect exchange that is mediated in both cases by a delocalized valence electron in a singly-occupied $4s$ derived orbital with an unpaired spin. This leads to total magnetic moments of 11 $\\mu_B$ for Mn$_2^+$ and 16 $\\mu_B$ for Mn$_3^+$, with no contribution of orbital angular momentum.

  20. Simultaneous qualitative and quantitative determination of phenolic compounds in Aloe barbadensis Mill by liquid chromatography-mass spectrometry-ion trap-time-of-flight and high performance liquid chromatography-diode array detector.

    Science.gov (United States)

    Wu, Xiaofang; Ding, Wenjing; Zhong, Jiasheng; Wan, Jinzhi; Xie, Zhiyong

    2013-06-01

    An effective and comprehensive method was developed for the simultaneous analysis of phenolic compounds in the dried exudate of Aloe barbadensis Mill by liquid chromatography-mass spectrometry-ion trap-time-of-flight (LCMS-IT-TOF) and high performance liquid chromatography-diode array detector (HPLC-DAD). Qualitative analysis of all the compounds presented in A. barbadensis Mill was performed on LCMS-IT-TOF, and the diagnostic fragmentation patterns of different types of phenolic compounds (chromones, phenyl pyrones, naphthalene derivative, anthrones and anthraquinones) were discussed on the basis of ESI-IT-TOF MS of components in A. barbadensis Mill and eleven authentic standards. Under the optimal HPLC-DAD chromatographic conditions, quantification of 11 typical phenolic compounds in 15 batches of A. barbadensis Mill was achieved on an Agilent TC-C18 column using gradient elution with a solvent system of methanol and water at a flow rate of 1.0mLmin(-1) and detected at 230nm. All calibration curves exhibited good linear relationship (r(2)>0.9991). The relative standard deviation values for intraday precision were less than 2% with accuracies between 98.21% and 104.57%. The recoveries of the eleven analytes ranged from 97.53 to 105.00% with RSDs less than 2%. This is the first simultaneous characterization and quantitative determination of multiple phenolic compounds in A. barbadensis Mill from locally grown cultivars in China by LCMS-IT-TOF and HPLC-DAD, which can be applied to standardize the quality of A. barbadensis Mill and the future design of nutraceutical and cosmetic preparations.

  1. Liquid chromatography/negative electrospray ionization ion trap MS(2) mass spectrometry application for the determination of microcystins occurrence in Southern Portugal water reservoirs.

    Science.gov (United States)

    Rodrigues, M A; Reis, M P; Mateus, M C

    2013-11-01

    Microcystins (MCs) are toxins produced by cyanobacteria which are common organisms in the phytoplankton of eutrophic lakes, rivers and freshwater reservoirs. In the present work, a novel method of liquid chromatography-electrospray ion trap tandem mass spectrometry (LC/ESI/Ion trap-MS/MS), operated in the negative ionization mode, was developed for the analysis of these cyanotoxins. The method was applied to determine the amounts of total microcystins-LR, -YR and -RR in two water reservoirs in Southern Portugal, namely Alqueva and Beliche. A total of 30 water samples were analysed along 2011. Solid phase extraction (SPE) was used for sample cleaning-up and analyte enrichment. The extracted toxins were separated on a C18 column with a gradient of acetonitrile/water with 0.1% formic acid. Detection of microcystins was carried out using multiple reaction monitoring (MRM) in the negative polarity mode, as this method gave a higher selectivity. The MC-RR, YR and LR quantification limits were 17.9, 31.7 and 15.8 ng/L, respectively; quite below the limits recommended by WHO guidelines for drinking water (1 μg/L). Total MC highest concentrations were found in the warm months of June, July and September in Alqueva sampling sites, with concentrations of MC LR and RR ranging 17-344 and 25-212 ng/L, respectively, showing comparable results for MC-RR and LR and slightly lower concentration of MC-YR. Detected values for Beliche reservoir were below quantification limits.

  2. Stability studies of propoxur herbicide in environmental water samples by liquid chromatography-atmospheric pressure chemical ionization ion-trap mass spectrometry.

    Science.gov (United States)

    Sun, Lei; Lee, Hian Kee

    2003-10-01

    Liquid chromatography-atmospheric pressure ionization ion-trap mass spectrometry has been investigated for the analysis of polar pesticides in water. The degradation behavior of propoxur, selected as a model pesticide belonging to the N-methylcarbamate group, in various aqueous matrices (Milli-Q water, drinking water, rain water, seawater and river water) was investigated. Two interfaces of atmospheric pressure ionization, atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI), were compared during the study. Propoxur and its transformation product (N-methylformamide) were best ionized as positive ions with both APCI and ESI, while another transformation product (2-isopropoxyphenol) yielded stronger signals as negative ions only with APCI. In addition, the effects of various pH, matrix type and irradiation sources (sunlight, darkness, indoor lighting and artificial UV lamp) on the chemical degradation (hydrolysis) were also assessed. From the kinetic studies of degradation, it was found that the half-life of propoxur was reduced from 327 to 161 h in Milli-Q water with variation of irradiation conditions from dark to sunlight exposure. Degradation rates largely increased with increasing pH. The half-life of the target compound dissolved in Milli-Q water under darkness decreased from 407 to 3 h when the pH of Milli-Q water was increased from 5 to 8.5. These suggest that hydrolysis of propoxur is light-intensity and pH-dependent. In order to mimic contaminated natural environmental waters, propoxur was spiked into real water samples at 30 microg/l. The degradation of propoxur in such water samples under various conditions were studied in detail and compared. With the ion trap run in a time-scheduled single ion monitoring mode, typical limits of detection of the instrument were in the range of 1-10 microg/l.

  3. Probing Ir-Induced Isomerization of a Model Pentapeptide in a Cryo-Cooled Ion Trap Using Ir-Uv Double Resonance

    Science.gov (United States)

    Harrilal, Christopher P.; DeBlase, Andrew F.; Fischer, Joshua L.; Lawler, John T.; McLuckey, Scott A.; Zwier, Timothy S.

    2017-06-01

    In the past decade, infrared and ultraviolet spectroscopy in cryo-cooled ion traps have become workhorse techniques to characterize the gas-phase 3D structures of biological ions. Often, multiple conformers of a single molecular ion are observed. While slow collisional cooling should result in funneling of many structures into a single minimum, recent studies show evidence for the kinetic trapping of entropically-favored structures near room temperature when these species are cooled to about 10K. In order to elucidate how the initial population fractionates during the cooling process, we use a variety of conformer specific IR-UV double resonance techniques to measure population distributions of the peptide ion [YGPAA+H]^{+} in the gas phase at 10K. Previous studies conducted in our lab show the YGPAA peptide adopts two spectroscopically distinct conformers which differ principally in the cis/trans configuration of the carboxylic acid group at the C-terminus. By using IR-UV hole filing spectroscopy (HFS) and population transfer spectroscopy (PTS) we demonstrate the ability to selectively excite and interconvert between conformations and to quantitatively measure the distribution of conformer populations within the ion trap. Experimentally, we find a 65:35 ratio for the trans:cis conformer population. These conformers are connected through a single calculated transition state, allowing intramolecular isomerization rates and equilibrium population distributions to be calculated by Rice-Ramsperger-Kassel-Marcus (RRKM) theory. The relationship between the observed population ratio and the temperature-dependent equilibrium constant will be discussed.

  4. Structural characterization of cyclosporin A, C and microbial bio-transformed cyclosporin A analog AM6 using HPLC-ESI-ion trap-mass spectrometry.

    Science.gov (United States)

    Ahn, Eun Young; Shrestha, Anil; Hoang, Nguyen Huu; Huong, Nguyen Lan; Yoon, Yeo Joon; Park, Je Won

    2014-06-01

    Cyclosporin A (CyA), a cyclic undecapeptide produced by a number of fungi, contains 11 unusual amino acids, and has been one of the most commonly prescribed immunosuppressive drugs. To date, there are over sixty different analogs reported as congeners and analogs resulting from precursor-directed biosynthesis, human CYP-mediated metabolites, or microbial bio-transformed analogs. However, there is still a need for more structurally diverse CyA analogs in order to discover new biological potentials and/or improve the physicochemical properties of the existing cyclosporins. As a result of the complexity of the resulting mass spectrometric (MS) data caused by its unusual amino acid composition and its cyclic nature, structural characterization of these cyclic peptides based on fragmentation patterns using multiple tandem MS analyses is challenging task. Here, we describe, an efficient HPLC-ESI-ion trap MS(n) (up to MS(8)) was developed for the identification of CyA and CyC, a (Thr(2))CyA congener in which L-aminobutyric acid (Abu) is replaced by L-threonine (Thr). In addition, we examined the fragmentation patterns of a CyA analog obtained from the cultivation of a recombinant Streptomyces venezuelae strain fed with CyA, assigning this analog as (γ-hydroxy-MeLeu(6))CyA (otherwise, known as an human CYP metabolite AM6). This is the first report on both the MS(n)-aided identification of CyC and the structural characterization of a CyA analog by employing HPLC-ESI-ion trap MS(n) analysis. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Metabolism studies of the Kratom alkaloid speciociliatine, a diastereomer of the main alkaloid mitragynine, in rat and human urine using liquid chromatography-linear ion trap mass spectrometry.

    Science.gov (United States)

    Philipp, Anika A; Wissenbach, Dirk K; Weber, Armin A; Zapp, Josef; Maurer, Hans H

    2011-03-01

    Mitragyna speciosa (Kratom) is currently used as a drug of abuse. When monitoring its abuse in urine, several alkaloids and their metabolites must be considered. In former studies, mitragynine (MG), its diastereomer speciogynine (SG), and paynantheine and their metabolites could be identified in rat and human urine using LC-MS(n). In Kratom users' urines, besides MG and SG, further isomeric compounds were detected. To elucidate whether the MG and SG diastereomer speciociliatine (SC) and its metabolites represent further compounds, the phase I and II metabolites of SC were identified first in rat urine after the administration of the pure alkaloid. Then, the identified rat metabolites were screened for in the urine of Kratom users using the above-mentioned LC-MS(n) procedure. Considering the mass spectra and retention times, it could be confirmed that SC and its metabolites are so far the unidentified isomers in human urine. In conclusion, SC and its metabolites can be used as further markers for Kratom use, especially by consumption of raw material or products that contain a high amount of fruits of the Malaysian plant M. speciosa.

  6. A comparative study of glycoprotein concentration, glycoform profile and glycosylation site occupancy using isotope labeling and electrospray linear ion trap mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Chih-Yu; Ma, Yi-Chun; Pai, Pei-Jing [Department of Chemistry, National Taiwan University, No.1, Sec. 4, Roosevelt Rd., Taipei 10617, Taiwan (China); Her, Guor-Rong, E-mail: grher@ntu.edu.tw [Department of Chemistry, National Taiwan University, No.1, Sec. 4, Roosevelt Rd., Taipei 10617, Taiwan (China)

    2012-05-30

    Highlights: Black-Right-Pointing-Pointer Concentration, site occupancy and glycoform variation can be differentiated. Black-Right-Pointing-Pointer Glycopeptides and peptides were stable isotope labeled and analyzed by ESI-MS. Black-Right-Pointing-Pointer Nonglycosylated peptide provided glycoprotein concentration variation. Black-Right-Pointing-Pointer Glycoform variation was obtained by comparing d{sub 0} and d{sub 4} labeled glycopeptides. Black-Right-Pointing-Pointer The variation of glycosylation site occupancy could be calculated. - Abstract: A strategy is presented for comparative analysis of glycoproteins in which the variation of protein concentration, variation of glycosylation site occupancy and variation of glycoform profile can be determined. A comparative study was performed using stable isotope labeling of glycopeptides and peptides by formaldehyde-H{sub 2} and formaldehyde-D{sub 2} and analysis by ESI-MS analysis. The relative intensity of the nonglycosylated peptide provided information about protein concentration variation. Variation of the glycoform profile was obtained by comparing the glycoform profile of d{sub 0}- and d{sub 4}-dimethyl labeled glycopeptides. By knowing the variation of protein concentration and the variation of glycoform profile, the variation of glycosylation site occupancy could be calculated. The utility of the proposed strategy was demonstrated with ribonuclease B with different protein concentrations, different levels of glycosylation site occupancy and different glycoform profiles.

  7. Hybrid fusion of linear, non-linear and spectral models for the dynamic modeling of sEMG and skeletal muscle force: an application to upper extremity amputation.

    Science.gov (United States)

    Potluri, Chandrasekhar; Anugolu, Madhavi; Schoen, Marco P; Subbaram Naidu, D; Urfer, Alex; Chiu, Steve

    2013-11-01

    Estimating skeletal muscle (finger) forces using surface Electromyography (sEMG) signals poses many challenges. In general, the sEMG measurements are based on single sensor data. In this paper, two novel hybrid fusion techniques for estimating the skeletal muscle force from the sEMG array sensors are proposed. The sEMG signals are pre-processed using five different filters: Butterworth, Chebychev Type II, Exponential, Half-Gaussian and Wavelet transforms. Dynamic models are extracted from the acquired data using Nonlinear Wiener Hammerstein (NLWH) models and Spectral Analysis Frequency Dependent Resolution (SPAFDR) models based system identification techniques. A detailed comparison is provided for the proposed filters and models using 18 healthy subjects. Wavelet transforms give higher mean correlation of 72.6 ± 1.7 (mean ± SD) and 70.4 ± 1.5 (mean ± SD) for NLWH and SPAFDR models, respectively, when compared to the other filters used in this work. Experimental verification of the fusion based hybrid models with wavelet transform shows a 96% mean correlation and 3.9% mean relative error with a standard deviation of ± 1.3 and ± 0.9 respectively between the overall hybrid fusion algorithm estimated and the actual force for 18 test subjects' k-fold cross validation data.

  8. On-line coupling of solid-phase extraction with mass spectrometry for the analysis of biological samples. II. Determination of clenbuterol in urine using multiple-stage mass spectrometry in an ion-trap mass spectrometer

    NARCIS (Netherlands)

    van Hout, MWJ; Hofland, CM; Niederlander, HAG; de Jong, GJ

    2000-01-01

    Solid-phase extraction (SPE) was coupled to ion-trap mass spectrometry to determine clenbuterol in urine. For SPE a cartridge exchanger was used and, after extraction, the eluate was directly introduced into the mass spectrometer, For two types of cartridges, i.e. C-18 and polydivinylbenzene (PDVB),

  9. Suitability of magnetic particle immunoassay for the analysis of PBDEs in Hawaiian freshwater fish and crabs in comparison with gas chromatography/electron capture detection-ion trap mass spectrometry

    Science.gov (United States)

    A gas chromatograph/electron capture detector-ion trap mass spectrometer (GC/ECD-ITMS) was used for the determination of polybrominated diphenyl ethers (PBDEs) in freshwater fish and crabs. The samples were also analyzed with an enzyme-linked immunosorbent assay (ELISA). GC/ECD-ITMS results showed...

  10. Optimization of Performance of Toroidal Ion Trap with Triangular Electrode by Theoretical Simulation%新型三角形电极圆环离子阱的理论模拟研究

    Institute of Scientific and Technical Information of China (English)

    杨海洋; 许崇晟; 岳磊; Mikhail Sudakov; 潘远江; 丁传凡

    2016-01-01

    The toroidal ion trap is an ideal candidate for miniaturized ion trap because it has much higher ion trapping capacity than a standard quadrupole ion trap of equal trapping dimensions. A novel toroidal ion trap mass analyzer with triangular electrode which contained a filament end cap, a detector endcap, an inner ring and an outer ring was reported. After designing and optimizing the electrodes by theoretical simulations, we found that the asymmetric triangle electrodes could reduce the affection from toroidal shape and improve the ion ejection rate and the mass resolution of the ion trap. The best design of the toroidal ion trap with a mass resolution of 1486 at m/z 609 was obtained.%圆环离子阱由于其离子储存能力明显优于相同体积下的三维离子阱,近年来被认为是离子阱小型化发展的另一个重要方向。为进一步优化圆环形离子阱的质谱性能,特别是质量分辨能力,本研究提出了一种由三角形电极构建的新型圆环离子阱,它由两个完全等同的、截面为三角形的圆环电极及两个大小不等的圆筒型电极所组成,离子通过共振激发方式弹出。通过理论模拟和对电极结构的优化,获得了具有非对称性的三角形电极结构,通过改善圆环结构,优化电场分布,提高了离子引出效率和离子阱的质量分辨能力,其中一种最优化结构的圆环离子阱对m/z 609离子的质量分辨率达到1486。

  11. An integrated ion trap and time-of-flight mass spectrometer for chemical and photo- reaction dynamics studies.

    Science.gov (United States)

    Schowalter, Steven J; Chen, Kuang; Rellergert, Wade G; Sullivan, Scott T; Hudson, Eric R

    2012-04-01

    We demonstrate the integration of a linear quadrupole trap with a simple time-of-flight mass spectrometer with medium-mass resolution (m/Δm ∼ 50) geared towards the demands of atomic, molecular, and chemical physics experiments. By utilizing a novel radial ion extraction scheme from the linear quadrupole trap into the mass analyzer, a device with large trap capacity and high optical access is realized without sacrificing mass resolution. This provides the ability to address trapped ions with laser light and facilitates interactions with neutral background gases prior to analyzing the trapped ions. Here, we describe the construction and implementation of the device as well as present representative ToF spectra. We conclude by demonstrating the flexibility of the device with proof-of-principle experiments that include the observation of molecular-ion photodissociation and the measurement of trapped-ion chemical reaction rates. © 2012 American Institute of Physics

  12. LC-ESI-MS/MS法测定人血浆中卢帕他定的浓度%Sensitive liquid chromatography electrospray ionization ion-trap mass spectrometry for the determination of rupatadine in human plasma

    Institute of Scientific and Technical Information of China (English)

    温预关; 喻凌寒; 彭建玲; 廖日房; 马崔

    2007-01-01

    Aim To develop and validate a sensitive and specific liquid chromatography electrospray ionization ion-trap mass spectrometry (LC-ESI-MS/MS) method for the identification and concentration of rupatadine in human plasma. Methods After the addition of the internal standard (IS, loratadine) and 0.01 mol·L-1 sodium hydroxide solution, plasma samples were extracted with methylene chloride: ethyl acetate mixture (20:80, V/V). The organic layer was evaporated under vacuum drying at 37℃. The residue was reconstituted with 200 μL mobile phase. Chromatography was performed on an Agilent Eclipse XDB-C18 (4.6 mm × 150 mm, 5 μm) column with a mobile phase consisting of acetonitrile (1% formic acid) -20 mmol·L-1 ammonium acetate (76:24, V/V) at a flow-rate of 0.6 mL·min-1. Detection was performed on Agilent MSD Trap XCT ion-trap mass spectrometry connected to a Agilent 1100 high performance liquid chromatography (HPLC) by selected reaction monitoring (SRM) mode via electrospray ionization (ESI) source. Rupatadine (MRM m/z 416 → 309) and loratadine (MRM m/z 383→ 337) were detected by Agilent MSD Trap XCT ion-trap mass analyser. Results The method was proved to be sensitive and specific by testing 20 different plasma batches. Linearity was established for the range of concentrations 0.05 - 14.0 ng·mL-1 with a coefficient of determination (r) of 0.998. The intra-and inter-day precision (RSD %) were lower than 15% and accuracy ranged from 85.1% to 114.0%. The lower limit of quantitation (LLOQ) was identifiable and reproducible at 0.05 ng·mL -1 with a precision of 9.22% (n =5). Conclusion The proposed method is sensitive and reproducible enough to be used in pharmacokinetic, bioavailability or bioequivalence studies of rupatadine.%目的 建立测定人血浆中卢帕他定浓度的LC-ESI-MS/MS方法.方法 血浆样品加入内标,碱化后用二氯甲烷:乙酸乙酯(20:80)提取,在37℃真空干燥箱中干燥至干,残渣用200 μL流动相溶解后进样.色谱

  13. Multiresidue Screening of Veterinary Drugs in Meat, Milk, Egg, and Fish Using Liquid Chromatography Coupled with Ion Trap Time-of-Flight Mass Spectrometry.

    Science.gov (United States)

    Kang, JeongWoo; Park, Su-Jeong; Park, Hae-Chul; Hossain, Md Akil; Kim, Myeong-Ae; Son, Seong-Wan; Lim, Chae-Mi; Kim, Tae-Wan; Cho, Byung-Hoon

    2017-06-01

    New approaches to veterinary drug screening based on liquid chromatography-mass spectrometry (LC-MS/MS) and time-of-flight mass spectrometry (ToF/MS) are rapid and have high selectivity and sensitivity. In this study, we developed a multiresidue method for screening over 100 veterinary drug residues using ion trap (IT)-ToF/MS. The screened compounds comprised major drug classes used in veterinary practice, representing the following: amphenicols, anthelmintics, benzimidazoles, β-lactams, coccidiostats, ionophores, macrolides, non-steroidal anti-inflammatory drugs, quinolones, sulfonamides, tetracyclines, and tranquilizers. The method was developed based on chromatographic retention time, specific accurate mass, isotope distribution, and fragment data. Each compound was validated at three levels, and the mass accuracy, accuracy, and repeatability were calculated. All parameters showed acceptable values and conformed to the Commission Decision 2002/657/EC criteria. This screening method can simultaneously analyze over 100 veterinary drugs in meat, milk, eggs, and fish in a single analytical run.

  14. Polar organic chemical integrative sampling and liquid chromatography- electrospray/ion-trap mass spectrometry for assessing selected prescription and illicit drugs in treated sewage effluents

    Science.gov (United States)

    Jones-Lepp, T. L.; Alvarez, D.A.; Petty, J.D.; Huckins, J.N.

    2004-01-01

    The purpose of the research presented in this paper was twofold: (1) to demonstrate the coupling of two state-of-the-art techniques: a time-weighted polar organic chemical integrative sampler (POCIS) and microliquid chromatography-electrospray/ion-trap mass spectrometry and (2) to assess the ability of these methodologies to detect six drugs (azithromycin, fluoxetine, omeprazole, levothyroxine, methamphetamine, methylenedioxymethamphetamine [MDMA]) in a real-world environment, e.g., waste water effluent. In the effluent from three wastewater treatment plants (WWTPs), azithromycin was detected at concentrations ranging from 15 to 66 ng/L, which is equivalent to a total annual release of 1 to 4 kg into receiving waters. Detected and confirmed in the effluent from two WWTPs were two illicit drugs, methamphetamine and MDMA, at 2 and 0.5 ng/L, respectively. Although the ecotoxicologic significance of drugs in environmental matrices, particularly water, has not been closely examined, it can only be surmised that these substances have the potential to adversely affect biota that are continuously exposed to them even at very low levels. The potential for chronic effects on human health is also unknown but of increasing concern because of the multi-use character of water, particularly in densely populated, arid areas.

  15. Determination of trace levels of herbicides and their degradation products in surface and ground waters by gas chromatography/ion-trap mass spectrometry

    Science.gov (United States)

    Pereira, W.E.; Rostad, C.E.; Leiker, T.J.

    1990-01-01

    A rapid, specific and highly sensitive method is described for the determination of several commonly used herbicides and their degradation products in surface and ground waters by using gas chromatography/ion-trap mass spectrometry. The compounds included atrazine, and its degradation products desethylatrazine and desisopropylatrazine; Simazine; Cyanazine; Metolachlor; and alachlor and its degradation products, 2-chloro-2', 6'-diethylacetanilide, 2-hydroxy-2', 6'-diethylacetanilide and 2,6-diethylaniline. The method was applied to surface-water samples collected from 16 different stations along the lower Mississippi River and its major tributaries, and ground-water samples beneath a cornfield in central Nebraska. Average recovery of a surrogate herbicide, terbuthylazine, was greater than 99%. Recoveries of the compounds of interest from river water spiked at environmental levels are also presented. Full-scan mass spectra of these compounds were obtained on 1 ng or less of analyte. Data were collected in the full-scan acquisition mode. Quantitation was based on a single characteristic ion for each compound. The detection limit was 60 pg with a signal-to-noise ratio of greater than 10:1.

  16. Analysis of polychlorinated dibenzo-p-dioxins, dibenzofurans and dioxin-like polychlorinated biphenyls in vegetable oil samples by gas chromatography-ion trap tandem mass spectrometry.

    Science.gov (United States)

    Malavia, J; Abalos, M; Santos, F J; Abad, E; Rivera, J; Galceran, M T

    2007-05-18

    Gas chromatography coupled to ion trap tandem mass spectrometry (CG-MS-MS) has been evaluated for the analysis of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (dl-PCBs) in vegetable oil samples containing different concentration levels (0.2-6 pg WHO-TEQ g(-1) for both PCDD/Fs and dl-PCBs) of the 29 toxic congeners of PCDD/F and dioxin-like PCBs. The effect of potential interfering compounds such as polychlorinated naphthalenes (PCNs), polychlorinated biphenyls (PCBs) and polychlorinated diphenylethers (PCDEs) on the quantification of mono-ortho PCBs has been investigated. In addition, the influence of the clean-up procedure on the final determination by CG-MS-MS was studied, showing that the quality of the results depends to a great extent on this analytical step. Quality parameters have been established and good precisions (CV: 3-19%) and low limits of detection for PCDD/Fs (0.04-0.20 pg g(-1) oil) and dl-PCBs (0.08-0.64 pg g(-1) oil) were obtained. The method was validated by a comparison of the CG-MS-MS results with those obtained by GC-HRMS.

  17. Generation of highly charged peptide and protein ions by atmospheric pressure matrix-assisted infrared laser desorption/ionization ion trap mass spectrometry.

    Science.gov (United States)

    König, Simone; Kollas, Oliver; Dreisewerd, Klaus

    2007-07-15

    We show that highly charged ions can be generated if a pulsed infrared laser and a glycerol matrix are employed for atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry with a quadrupole ion trap. Already for small peptides like bradykinin, doubly protonated ions form the most abundant analyte signal in the mass spectra. The center of the charge-state distribution increases with the size of the analyte. For example, insulin is detected with a most abundant ion signal corresponding to a charge state of four, whereas for cytochrome c, the 10 times protonated ion species produces the most intense signal. Myoglobin is observed with up to 13 charges. The high m/z ratios allow us to use the Paul trap for the detection of MALDI-generated protein ions that are, owing to their high molecular weight, not amenable in their singly protonated charge state. Formation of multiple charges critically depends on the addition of diluted acid to the analyte-matrix solution. Tandem mass spectra generated by collision-induced dissociation of doubly charged peptides are also presented. The findings allow speculations about the involvement of electrospray ionization processes in these MALDI experiments.

  18. Characterization of cardamonin metabolism by P450 in different species via HPLC-ESI-ion trap and UPLC-ESI-quadrupole mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Yuqi HE; Li YANG; Yong LIU; Jiang-wei ZHANG; Jun TANG; Juan SU; Yuan-yuan LI; Yan-liu LU; Chang-hong WANG; Ling YANG; Zheng-tao WANG

    2009-01-01

    Aim:To characterize the metabolism of cardamonin by the P450 enzymes in human and animal liver microsomes. Methods: Cardamonin was incubated with both human and animal liver microsomal incubation systems containing P450 reaction factors. High performance liquid chromatography coupled with ion trap mass spectrometry was used to identify the metabolites. Serial cardamonin dilutions were used to perform a kinetic study in human liver microsomes. Selective inhibitors of 7 of the major P450 isozymes were used to inhibit cardamonin hydroxylation to identify the isozymes involved in cardamonin metabolism. The cardamonin hydroxylation metabolic capacities of human and various other animals were investigated using the liver microsomal incubation system.Results: Two metabolites generated by the liver microsome system were detected and identified as hydroxylated cardamonin. The K_m and V_ (max) values for cardamonin hydroxylation were calculated as 32μmol/L and 35 pmotmol·~(-1)·mg~(-1), respectively.Fruafylline and clomethiazole significantly inhibited cardamonin hydroxylation. Guinea pigs showed the highest similarity to humans with respect to the metabolism of cardamonin.Conclusion: CYP 1A2 and 2E1 were identified as the P450 isozymes involved in the metabolism of cardamonin in human liver microsomes. Furthermore, our research suggests that guinea pigs could be used in the advanced pharmacokinetic studies of cardamonin in vivo.

  19. Suitability of selective pressurized liquid extraction combined with gas chromatography-ion-trap tandem mass spectrometry for the analysis of polybrominated diphenyl ethers.

    Science.gov (United States)

    Losada, S; Parera, J; Abalos, M; Abad, E; Santos, F J; Galceran, M T

    2010-09-23

    A one-step extraction and clean-up method using pressurized liquid extraction (PLE) (selective PLE) combined with gas chromatography-ion-trap tandem mass spectrometry (GC-ITMS-MS) was evaluated for the analysis of polybrominated diphenyl ethers (from tri- to hepta-PBDEs) at low concentrations in fish and shellfish samples. To this end, the performance of an on-line PLE extraction/clean-up method and of a classical Soxhlet extraction and clean-up method using a multi-layer modified silica column were compared. The two sample treatment methods provided similar results, although an important reduction in the sample treatment time (40 min per sample) was achieved using the selective PLE method. In addition, the suitability of the PLE combined with GC-ITMS-MS method was evaluated by comparing the results obtained in the analysis of fish samples with those obtained by gas chromatography-high resolution mass spectrometry (GC-HRMS). Good agreement between both techniques was obtained with differences between the mean values of less than 16%. The selective PLE method coupled to GC-ITMS-MS produced accurate results for PBDE determination with low limits of detection (1.0-16.8 pg g(-1) wet weight) and quantification (3.1-51 pg g(-1) wet weight) as well as good precision (RSD<16%). This method has been applied to the analysis of PBDEs in fish and shellfish samples collected at fish markets in Catalonia (NE Spain).

  20. Investigation of Symphytum cordatum alkaloids by liquid-liquid partitioning, thin-layer chromatography and liquid chromatography-ion-trap mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Mroczek, Tomasz [Department of Pharmacognosy with Medicinal Plants Laboratory, Medical University, 1 Chodzki St., 20-093 Lublin (Poland)]. E-mail: tmroczek@pharmacognosy.org; Ndjoko-Ioset, Karine [Laboratoire de Pharmacognosie et Phytochimie, Ecole de Pharmacie Geneve-Lausanne, Universite de Geneve, Quai Ernest-Ansermet 30, CH-1211 Geneva 4 (Switzerland); Glowniak, Kazimierz [Department of Pharmacognosy with Medicinal Plants Laboratory, Medical University, 1 Chodzki St., 20-093 Lublin (Poland); Mietkiewicz-Capala, Agnieszka [Department of Pharmacognosy with Medicinal Plants Laboratory, Medical University, 1 Chodzki St., 20-093 Lublin (Poland); Hostettmann, Kurt [Laboratoire de Pharmacognosie et Phytochimie, Ecole de Pharmacie Geneve-Lausanne, Universite de Geneve, Quai Ernest-Ansermet 30, CH-1211 Geneva 4 (Switzerland)

    2006-05-04

    From the alkalised crude extract of Symphytum cordatum (L.) W.K. roots, pyrrolizidine alkaloids (PAs) were extracted as free tertiary bases and polar N-oxides in a merely one-step liquid-liquid partitioning (LLP) in separation funnel and subsequently pre-fractionated by preparative multiple-development (MD) thin-layer chromatography (TLC) on silica gel plates. In this way three alkaloid fractions of different polarities and retention on silica gel plates were obtained as: the most polar N-oxides of the highest retention, the tertiary bases of medium retention, and diesterified N-oxides of the lowest retention. The former fraction was reduced into free bases by sodium hydrosulfite and purified by LLP on Extrelut-NT3 cartridge. It was further analysed together with the two other fractions by high-performance liquid chromatography (HPLC)-ion-trap mass spectrometry with atmospheric pressure chemical ionization (APCI) interface on XTerra C{sub 18} column using a gradient elution. Based on MS {sup n} spectra, 18 various alkaloids have been tentatively determined for the first time in this plant as the following types of structure: echimidine-N-oxide (three diasteroisomers), 7-sarracinyl-9-viridiflorylretronecine (two diasteroisomers), echimidine (two diasteroisomers), lycopsamine (two diasteroisomers), dihydroechinatine-N-oxide, dihydroheliospathuline-N-oxide, lycopsamine-N-oxide (three diasteroisomers), 7-acetyllycopsamine-N-oxide, symphytine-N-oxide (two diasteroisomers) and 2'',3''-epoxyechiumine-N-oxide.