WorldWideScience

Sample records for hybrid ga-67 spect

  1. {sup 67}Ga-SPECT/CT with a hybrid system in the clinical management of lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Palumbo, Barbara; Sivolella, Silvio; Palumbo, Renato [University of Perugia, Nuclear Medicine Section, Department of Radiological Sciences, Perugia (Italy); Palumbo, Isabella; Liberati, Anna Marina [University of Perugia, Internal Medicine and Oncology, Department of Clinical and Experimental Medicine, Perugia (Italy)

    2005-09-01

    The purpose of this study was to investigate the added value of co-registered fusion imaging using a hybrid system in patients with lymphoma. Twenty-four lymphoma patients underwent {sup 67}Ga-SPECT/CT using a hybrid tomograph consisting of a dual-head, variable-angle gamma camera and a low-dose X-ray tube. Results were compared with those of SPECT alone. Forty-five lesions were identified by SPECT alone, while 49 were detected by SPECT/CT. Forty out of the 45 lesions observed on SPECT were confirmed as lymphoma, but five were due to other causes (thoracic aorta blood pool activity, sialoadenitis in the submandibular gland, bowel activity, rib fracture and bone marrow activation due to radiotherapy). SPECT/CT identified nine more neoplastic lesions compared with SPECT alone: four areas of radiopharmaceutical accumulation were observed in para-aortic lymph nodes, three in the spleen, one in the liver and one in para-iliac lymph nodes. In five cases, SPECT/CT provided additional anatomical information over SPECT alone. In four patients, four large areas of {sup 67}Ga uptake (one mediastinal, two supraclavicular and one para-aortic) were better characterised; in one subject uptake was localised in the seventh thoracic vertebra only by SPECT/CT. Hybrid imaging provided additional data in 13 patients (54.2%), thus inducing oncologists to reconsider the therapeutic approach in eight subjects (33.2%): unnecessary treatment was avoided in four (16.6%) while therapy was altered in another four (16.6%). SPECT/CT hybrid system is able to provide information not obtained by SPECT alone. It allows the anatomical localisation of lymphoma and physiological radiopharmaceutical uptake, facilitates the diagnosis of tumours located in the abdomen (subdiaphragmatic lesions) and provides information that may cause a change in therapeutic strategy. (orig.)

  2. Usefulness of Ga-67 citrate whole body imaging, chest spot imaging, and chest SPECT in sarcoidosis

    International Nuclear Information System (INIS)

    Ueno, Kyoichi; Nishi, Koichi; Namura, Masanobu; Kawashima, Yoshio; Kurumaya, Hiroshi

    1999-01-01

    To assess the sensitivity, and the relative role of Ga-67 whole body, chest spot imaging, and chest SPECT, we retrospectively studied 34 cases of sarcoidosis (24 biopsy proven, 10 clinically diagnosed) with Ga-67 (111 MBq), and compared the results of lung (25 cases), muscle (25 cases), skin (3 cases), and myocardial (2 cases) biopsies. Ga-67 chest SPECT (single photon emission CT) were done in 17 cases with Siemens MultiSPECT3. Ga-67 planar imaging visualized only 2 of 12 (16.7%) lung biopsy-positive cases, 5 of 12 (41.6%) muscle biopsy-positive cases, 2 of 3 (66.7%) skin biopsy-positive cases. However, Ga-67 imaging revealed the lesions in 1 of 9 (11.1%) of muscle biopsy-negative cases, in 2 of 3 (66.7%) of skin biopsy-negative cases, and in 1 of 2 myocardial biopsy-negative cases. Ga-67 chest SPECT visualized 14 hilar lymphadenopathy (LN), 3 supraclavicular LN, and 1 myocardial sarcoidosis. Although both SPECT, and planar spot imaging detected the lesions equally, the former showed them more clearly. Compared with various biopsies, the sensitivity of Ga-67 imaging was not so high. However, Ga-67 imaging is non-invasive, easy to perform the whole body imaging, and can detect the activity of the lesions. Ga-67 SPECT showed clear imaging of the hilar, mediastinal LN, and potentially fatal myocardial sarcoidosis. (author)

  3. 18F-FDG PET is superior to 67Ga SPECT in the staging of non-Hodgkin's lymphoma

    International Nuclear Information System (INIS)

    Yamamoto, Fumiyasu; Tsukamoto, Eriko; Nakada, Kunihiro; Takei, Toshiki; Zhao, Songji; Asaka, Masahiro; Tamaki, Nagara

    2004-01-01

    Our study aims to compare diagnostic accuracy between 18 F-FDG PET and 67 Ga SPECT in the staging of non-Hodgkin's lymphoma. Twenty-eight patients with non-Hodgkin's lymphoma, underwent 18 F-FDG PET, 67 Ga SPECT and CT for the pretreatment staging of malignant lymphoma between August 1999 and March 2002. 18 F-FDG PET imaging was obtained 60 minutes after the intravenous administration of 185 MBq of 18 F-FDG. 67 Ga SPECT imaging was obtained 2 days after the intravenous administration of 148 MBq of 67 Ga. 18 F-FDG PET and 67 Ga SPECT were performed within one month. Both imagings were performed on the area from the neck to the pelvis. The 18 F-FDG PET and 67 Ga SPECT findings were compared with the CT findings and the clinical course. Sixty-six nodal lesions were clinically confirmed. Of these, 32 were identified by both 18 F-FDG PET and 67 Ga SPECT. The remaining 34 lesions were identified only by 18 F-FDG PET. The mean (±SD) sizes of the nodes were 34.7±32.4 mm for 18 F-FDG-positive and 67 Ga-positive lesions and 15.7±8.3 mm for 18 F-FDG-positive and 67 Ga-negative lesions (p 18 F-FDG PET and 67 Ga SPECT, whereas 6 lesions were identified by only 18 F-FDG PET. Five lesions were not identified by either technique. No 18 F-FDG-negative but 67 Ga-positive nodal or extranodal lesions were observed. The difference in findings between the two studies is related to the difference in the size but not in the histology or site of the lesions. 18 F-FDG PET detected significantly more lesions particularly small lesions than 67 Ga SPECT. Thus, 18 F-FDG PET is considered to be superior to 67 Ga SPECT in the staging of non-Hodgkin's lymphoma. (author)

  4. Tc-99m-MDP/Ga-67 SPECT in the evaluation of otitis externa

    International Nuclear Information System (INIS)

    Tumeh, S.S.; Hamdan, U.; Desisto, W.; English, R.J.

    1988-01-01

    Four patients with otitis externa were studied with Tc-99m MDP and Ga-67 single photon emission computed tomography (SPECT). In addition to the abnormal uptake in the external ear seen with planar imaging, SPECT demonstrated mastoid uptake (proved clinically) that was not appreciated with planar imaging in three patients, one of whom had negative x-ray computed tomographic (CT) findings. In one patient, SPECT demonstrated midline uptake in the skull base that was not depicted by x-ray CF.No false-positive results were seen. The authors conclude that Tc-99m MDP/Ga-67 SPECT is superior to planar imaging and should be used in the evaluation of otitis externa

  5. Basic study for the purpose of developing a quantitative "6"7Ga-SPECT measurement method

    International Nuclear Information System (INIS)

    Nakanishi, Kensuke; Sakata, Reiki; Takaki, Akihiro; Ito, Shigeki; Nakasone, Yutaka; Kadota, Masataka

    2017-01-01

    "6"7Ga-single photon emission computed tomography (SPECT) images vary according to the imaging time and image display methods. The calculation of an index, such as the standardized uptake value used in positron emission tomography, from "6"7Ga-SPECT images would enable the accurate evaluation of the region of accumulation. The purpose of this study was to elucidate the conversion formula, the lower detection limit (LDL), and recovery coefficient (RC) for quantifying the radiation concentration in the "6"7Ga accumulation site. After chronologically obtaining SPECT/CT images at a radiation concentration of 1.0-442.4 kBq/mL with 27 bottles (diameter: 48 mm ,100 mL), the radiation concentration conversion formula was calculated using the successive approximation reconstruction method. The conversion coefficient was then calculated from the relationship between the count rate and the radiation concentration, and the LDL was determined. To compensate for the partial volume effect, the recovery curve was calculated using the mean SPECT count for six bottles (diameter: 9 ,18 , 29, 38, 48, and 94 mm). There was a linear relationship between the radiation concentration and the count rate with a good correlation (r=0.99). The LDL was 1.0 kBq/mL. The recovery curve reached a plateau at a diameter of at least 48 mm. The calculation of the absorbed dose index was possible using the radiation concentration conversion formula and the RC. (author)

  6. Usefulness of emission CT in 67Ga tumor and inflammation scintigraphy

    International Nuclear Information System (INIS)

    Koizumi, Kiyoshi; Tada, Akira; Bunko, Hisashi; Tonami, Norihisa; Hisada, Kinichi.

    1983-01-01

    67 Ga-citrate widely used for tumor imaging has some drawbacks. Poor blood elearance of 67 Ga is sometimes a cause of poor visualization of the abnormal uptake in lesions. Physiological accumulations of 67 Ga (e. g. liver, colon, pulmonary hilus, etc.) also conceal the abnormal 67 Ga uptake in lesions. We have evaluated the usefulness of 67 Ga SPECT (single photon emission CT) to overcome these drawbacks inherent in conventional gamma-camera images. 67 Ga SPECT was more useful to recognize the location and the extension of lesions in transaxial planes, therefore, comparison of the lesions with transmission CT was easily made. Abnormal accumulation in or near the liver was easily discriminated from the physiological accumulation of 67 Ga in the liver. Further evaluation of the lesions which had been detected by other imaging methods (e. g. transmission CT, ultrasonography, etc.), 67 Ga SPECT was more useful than conventional gamma-camera imaging. In conclusion, 67 Ga SPECT was useful in selected cases when performed after conventiond 67 Ga imaging. (author)

  7. A comparison of high dose Ga-67 SPECT and FDG PET imaging in malignant melanoma

    International Nuclear Information System (INIS)

    Kaliff, V.; Hicks, R.J.; Binns, D.S.; Henderson, M.A.; Ainslie, J.; Jenner, D.A.

    1998-01-01

    Full text: Ga-67 imaging for tumour localisation lost favour in the 1970's. With improvement in technology and use of higher doses, it has now found an important role in lymphoma. A similar phenomenon may be possible in the staging of melanoma. This study therefore compares high dose (370 MBq) Ga-67 imaging using a day 5 and 7 whole-body and comprehensive SPECT protocol, with (100 MBq) F-18 fluorodeoxyglucose (FDG) imaging using positron emission tomography (PET): a technique recently shown to be highly accurate in this condition. 85 patients; 46 males, mean age 52+17 yrs: range 22-83 yrs, underwent both studies within 9±16 days (max-91 days). Scans were judged as positive (+ve), negative (-ve) or equivocal (EQ) for local, regional and distant disease. Clinical follow-up resolved discordant scan findings. PET and Ga-67 results were concordant in 61 (70%) patients (19 with +ve, 37 -ve and 5 EQ scans). None of the 9 ps with one EQ and one eye scan had disease on follow-up. Follow-up was available in 4/5 patients with discordantly +ve (3 patients) or more extensive Ga-67 abnormality: 3 patients had disease confirmed, 1 patient false +ve (asymmetric lung hilum). Follow-up was available in 9/10 patients with discordantly +ve (3 patients) or more extensive PET abnormality: 4 patients had confirmed disease, l pt false +ve (bladder diverticulum). A further 4 patients had second primaries (2 rectal carcinomas, 1 plasmacytoma, 1 basal cell carcinoma). High dose Ga-67 scanning incorporating SPECT appears to be a reasonable alternative to FDG PET for screening patients with melanoma. In this series PET's main advantages were in the detection of other occult tumours, greater patient convenience and lower radiation dosimetry

  8. Study on the usefulness of whole body SPECT coronal image, MIP image in 67Ga scintigraphy

    International Nuclear Information System (INIS)

    Kawamura, Seiji

    2002-01-01

    In this study, we examined the usefulness of whole body coronal images and whole body cine display MIP images (CMIP) upon which image processing was carried out after whole body SPECT in comparison to the usefulness of whole body images (WB/SC) compensated by scattered radiation in tumor/inflammation scintigraphy with 67 Ga-citrate ( 67 Ga). Image interpretation was performed for the 120 patients with confirmed diagnoses, and the accuracy of their diagnoses was studied by three nuclear medical physicians and two clinical radiological technologists by means of sensitivity, specificity and ROC analysis. The resultant data show that sensitivity, specificity, accuracy and the area under the ROC curve Az in the WB/SC were approximately 65%, 86%, 74% and 0.724, respectively, whereas sensitivity, specificity, accuracy and Az of the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method were approximately 93%, 95%, 94% and 0.860, respectively. Furthermore, coronal images reconstructed by the OS-EM method tended to be superior to those produced by the FBP method in both diagnostic accuracy and ROC analysis. In conclusion, the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method was shown to be superior in diagnostic accuracy and ROC analysis. Our data suggest that whole body SPECT is an excellent technique as an alternative to WB/SC. (author)

  9. Study on the usefulness of whole body SPECT coronal image, MIP image in {sup 67}Ga scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, Seiji [Kurume Univ., Fukuoka (Japan). Hospital; Ishibashi, Masatoshi; Kurata, Seiji; Morita, Seiichirou; Hayabuchi, Naofumi [Kurume Univ., Fukuoka (Japan). School of Medicine; Fukushima, Shigehiro [Kyushu Inst. of Design, Fukuoka (Japan). Graduate School of Auditory and Visual Communication Sciences; Umezaki, Noriyoshi [Daiichi Coll. of Pharmaceutical Sciences, Fukuoka (Japan)

    2002-05-01

    In this study, we examined the usefulness of whole body coronal images and whole body cine display MIP images (CMIP) upon which image processing was carried out after whole body SPECT in comparison to the usefulness of whole body images (WB/SC) compensated by scattered radiation in tumor/inflammation scintigraphy with {sup 67}Ga-citrate ({sup 67}Ga). Image interpretation was performed for the 120 patients with confirmed diagnoses, and the accuracy of their diagnoses was studied by three nuclear medical physicians and two clinical radiological technologists by means of sensitivity, specificity and ROC analysis. The resultant data show that sensitivity, specificity, accuracy and the area under the ROC curve Az in the WB/SC were approximately 65%, 86%, 74% and 0.724, respectively, whereas sensitivity, specificity, accuracy and Az of the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method were approximately 93%, 95%, 94% and 0.860, respectively. Furthermore, coronal images reconstructed by the OS-EM method tended to be superior to those produced by the FBP method in both diagnostic accuracy and ROC analysis. In conclusion, the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method was shown to be superior in diagnostic accuracy and ROC analysis. Our data suggest that whole body SPECT is an excellent technique as an alternative to WB/SC. (author)

  10. Quantitation of abnormal Ga-67 uptake in idiopathic pulmonary fibrosis

    International Nuclear Information System (INIS)

    O'Donnell, J.K.; Golish, J.A.; Cordasco, E.M.; Go, R.T.; Feiglin, D.H.; MacIntyre, W.J.

    1987-01-01

    Gallium-67 is useful in differentiating active pneumonitis from the underlying changes of diffuse idiopathic pulmonary fibrosis (IPF), especially when advanced disease precludes detection of subtle radiographic changes. Diffuse Ga-67 uptake, however, is often difficult to estimate. For 22 patients with IPF, they employed both emission tomography (SPECT) of the thorax and a modified Ga-67 index technique for digital planar images basing lung regions on Tc-99m MAA outlines and background on thigh soft-tissue activity. The degree of abnormal Ga-67 uptake measured by these techniques correlated closely with disease activity by all clinical criteria. Repeat studies for six patients after steroid therapy paralleled clinical response (4+/2-)

  11. Clinical evaluation of 67Ga gut accumulation in 67Ga scintigraphy

    International Nuclear Information System (INIS)

    Kobayashi, Hidetoshi; Ohno, Akiko; Watanabe, Youichi; Ishigaki, Takeo.

    1994-01-01

    Accumulation of 67 Ga in gut was evaluated in 67 Ga scintigraphy retrospectively in 30 patients (32 examinations). TIBC and UIBC were examined in all patients on the day when their scintigraphies were performed. Blood transfusion or Fe administration 2 months before 67 Ga scintigraphies were not carried out in any patient. Fifty percents (6/12) of male, and 40% (8/20) of female patients showed 67 Ga accumulation in gut. There was significant correlation between 67 Ga accumulation in gut and low ion-saturation ratio for transferrin. Excretion of 67 Ga bound with transferrin from liver was thought to be an important factor of 67 ga accumulation in gut. (author)

  12. [67Ga]Gallium-complex with 2-acetylpyridine N4-ortho fluorophenylthiosemicarbazone as a radiotracer for brain tumor diagnosis

    International Nuclear Information System (INIS)

    Pesquero, Jorge L.

    2011-01-01

    The aim of this work was to develop a 67 Ga-based SPECT imaging agent derived from 2-acetylpyridine N4-orthofluorophenyl - thiosemicarbazone (PhoF). For this purpose, PhoF was radiolabeled using 67 Ga as radiotracer, and after quality control analysis its biodistribution and SPECT imaging were evaluated on Swiss mice and Nude mice bearing glioblastoma multiform tumor (U87-MG). The labelling of PhoF with 67 GaCl 3 was performed in methanol for 30 minutes at room temperature. Radiochemical analyses were done by HPLC with radioactivity detection. 67 Ga- PhoF was successful produced with 97.5 ± 0.6% of radiochemical purity and high specific activity (1.0 TBq /mmol). 67 Ga- PhoF showed to be a stable compound keeping its stability, when stored at 2-4 deg C. In biodistribution studies, 67 Ga- PhoF displayed not only a significant tumor uptake, but also rapid blood clearance (T 1/2 fast phase = 3.7 min. and T 1/2 slow phase = 127.2 min.) and low accumulations in non target tissues, resulting in high target-to-non target ratios. Scintigraphic images of 67 Ga- PhoF in nude mice bearing U87-MG tumor showed a significant activity in tumor (∼ 7% of total activity) and tumor-to-normal tissue ratio was more than 10-fold higher depending on the organ. Our results suggest that 67 Ga-PhoF possess indispensable characteristics for a good radiopharmaceutical for brain tumor diagnosis. (author)

  13. [{sup 67}Ga]Gallium-complex with 2-acetylpyridine N4-ortho fluorophenylthiosemicarbazone as a radiotracer for brain tumor diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Pesquero, Jorge L. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. de Fisiologia e Biofisica; Pujatti, Priscilla B.; Araujo, Elaine B. de [Instituto de Pesquisas Energeticas Nucleares (DIRF/IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Diretoria de Radiofarmacia; Lessa, Josane A.; Beraldo, Heloisa [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. de Quimica; Soares, Marcella A.; Santos, Raquel G. dos, E-mail: santosr@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    The aim of this work was to develop a {sup 67}Ga-based SPECT imaging agent derived from 2-acetylpyridine N4-orthofluorophenyl - thiosemicarbazone (PhoF). For this purpose, PhoF was radiolabeled using {sup 67}Ga as radiotracer, and after quality control analysis its biodistribution and SPECT imaging were evaluated on Swiss mice and Nude mice bearing glioblastoma multiform tumor (U87-MG). The labelling of PhoF with {sup 67}GaCl{sub 3} was performed in methanol for 30 minutes at room temperature. Radiochemical analyses were done by HPLC with radioactivity detection. {sup 67}Ga- PhoF was successful produced with 97.5 {+-} 0.6% of radiochemical purity and high specific activity (1.0 TBq /mmol). {sup 67}Ga- PhoF showed to be a stable compound keeping its stability, when stored at 2-4 deg C. In biodistribution studies, {sup 67}Ga- PhoF displayed not only a significant tumor uptake, but also rapid blood clearance (T{sub 1/2} {sub fast} {sub phase}= 3.7 min. and T{sub 1/2} {sub slow} {sub phase}= 127.2 min.) and low accumulations in non target tissues, resulting in high target-to-non target ratios. Scintigraphic images of {sup 67}Ga- PhoF in nude mice bearing U87-MG tumor showed a significant activity in tumor ({approx} 7% of total activity) and tumor-to-normal tissue ratio was more than 10-fold higher depending on the organ. Our results suggest that {sup 67}Ga-PhoF possess indispensable characteristics for a good radiopharmaceutical for brain tumor diagnosis. (author)

  14. Preparation and anatomical distribution study of 67Ga-alginic acid nanoparticles for SPECT purposes in rainbow trout (Oncorhynchus mykiss

    Directory of Open Access Journals (Sweden)

    Heidarieh Marzieh

    2014-12-01

    Full Text Available Ergosan contains 1% alginic acid extracted from two brown sea weeds. Little is known about the target organs and anatomical distribution of Ergosan (alginic acid in fish. Therefore, feasibility of developing alginic acid nanoparticles to detect target organ in rainbow trout is interesting. To make nanoparticles, Ergosan extract (alginic acid was irradiated at 30 kGy in a cobalt-60 irradiator and characterized by transmission electron microscopy (TEM and Fourier transform infrared spectroscopy (FTIR. Results from TEM images showed that particle sizes of irradiated alginic acid ranged from 30 to 70 nm. The FTIR results indicated that gamma irradiation had no significant influence on the basic structure of alginic acid. Later, alginic acid nanoparticles were successively labelled with 67Ga-gallium chloride. The biodistribution of irradiated Ergosan in normal rainbow trout showed highest uptake in intestine and kidney and then in liver and kidney at 4- and 24-h post injection, respectively. Single-photon emission computed tomography (SPECT images also demonstrated target specific binding of the tracer at 4- and 24-h post injection. In conclusion, the feed supplemented with alginic acid nanoparticles enhanced SPECT images of gastrointestinal morphology and immunity system in normal rainbow trout.

  15. SPECT/CT with radiolabeled somatostatin analogues in the evaluation of systemic granulomatous infections.

    Science.gov (United States)

    Monteiro, Paulo Henrique Silva; de Souza, Thiago Ferreira; Moretti, Maria Luiza; Resende, Mariangela Ribeiro; Mengatti, Jair; de Lima, Mariana da Cunha Lopes; Santos, Allan Oliveira; Ramos, Celso Darío

    2017-01-01

    To evaluate SPECT/CT with radiolabeled somatostatin analogues (RSAs) in systemic granulomatous infections in comparison with gallium-67 ( 67 Ga) citrate scintigraphy. We studied 28 patients with active systemic granulomatous infections, including tuberculosis, paracoccidioidomycosis, pneumocystosis, cryptococcosis, aspergillosis, leishmaniasis, infectious vasculitis, and an unspecified opportunistic infection. Of the 28 patients, 23 had started specific treatment before the study outset. All patients underwent whole-body SPECT/CT imaging: 7 after injection of 99m Tc-EDDA-HYNIC-TOC, and 21 after injection of 111 In-DTPA-octreotide. All patients also underwent 67 Ga citrate imaging, except for one patient who died before the 67 Ga was available. In 20 of the 27 patients who underwent imaging with both tracers, 27 sites of active disease were detected by 67 Ga citrate imaging and by SPECT/CT with an RSA. Both tracers had negative results in the other 7 patients. RSA uptake was visually lower than 67 Ga uptake in 11 of the 20 patients with positive images and similar to 67 Ga uptake in the other 9 patients. The only patient who did not undergo 67 Ga scintigraphy underwent 99m Tc-EDDA-HYNIC-TOC SPECT/CT-guided biopsy of a lung cavity with focal RSA uptake, which turned to be positive for aspergillosis. SPECT/CT with 99m Tc-EDDA-HYNIC-TOC or 111 In-DTPA-octreotide seems to be a good alternative to 67 Ga citrate imaging for the evaluation of patients with systemic granulomatous disease.

  16. SPECT/CT with radiolabeled somatostatin analogues in the evaluation of systemic granulomatous infections

    International Nuclear Information System (INIS)

    Monteiro, Paulo Henrique Silva; Souza, Thiago Ferreira de; Moretti, Maria Luiza; Resende, Mariangela Ribeiro; Lima, Mariana da Cunha Lopes de; Santos, Allan Oliveira; Ramos, Celso Darío

    2017-01-01

    Objective: To evaluate SPECT/CT with radiolabeled somatostatin analogues (RSAs) in systemic granulomatous infections in comparison with gallium-67 ( 67 Ga) citrate scintigraphy. Materials And Methods: We studied 28 patients with active systemic granulomatous infections, including tuberculosis, paracoccidioidomycosis, pneumocystosis, cryptococcosis, aspergillosis, leishmaniasis, infectious vasculitis, and an unspecified opportunistic infection. Of the 28 patients, 23 had started specific treatment before the study outset. All patients underwent whole-body SPECT/CT imaging: 7 after injection of 99m Tc-EDDA-HYNIC-TOC, and 21 after injection of 111 In-DTPA-octreotide. All patients also underwent 67 Ga citrate imaging, except for one patient who died before the 67 Ga was available. Results: In 20 of the 27 patients who underwent imaging with both tracers, 27 sites of active disease were detected by 67 Ga citrate imaging and by SPECT/CT with an RSA. Both tracers had negative results in the other 7 patients. RSA uptake was visually lower than 67 Ga uptake in 11 of the 20 patients with positive images and similar to 67 Ga uptake in the other 9 patients. The only patient who did not undergo 67 Ga scintigraphy underwent 99m Tc-EDDA-HYNIC-TOC SPECT/CT-guided biopsy of a lung cavity with focal RSA uptake, which turned to be positive for aspergillosis. Conclusion: SPECT/CT with 99m Tc-EDDA-HYNIC-TOC or 111 In-DTPA-octreotide seems to be a good alternative to 67 Ga citrate imaging for the evaluation of patients with systemic granulomatous disease. (author)

  17. SPECT/CT with radiolabeled somatostatin analogues in the evaluation of systemic granulomatous infections

    Directory of Open Access Journals (Sweden)

    Paulo Henrique Silva Monteiro

    2017-10-01

    Full Text Available Abstract Objective: To evaluate SPECT/CT with radiolabeled somatostatin analogues (RSAs in systemic granulomatous infections in comparison with gallium-67 (67Ga citrate scintigraphy. Materials and Methods: We studied 28 patients with active systemic granulomatous infections, including tuberculosis, paracoccidioidomycosis, pneumocystosis, cryptococcosis, aspergillosis, leishmaniasis, infectious vasculitis, and an unspecified opportunistic infection. Of the 28 patients, 23 had started specific treatment before the study outset. All patients underwent whole-body SPECT/CT imaging: 7 after injection of 99mTc-EDDA-HYNIC-TOC, and 21 after injection of 111In-DTPA-octreotide. All patients also underwent 67Ga citrate imaging, except for one patient who died before the 67Ga was available. Results: In 20 of the 27 patients who underwent imaging with both tracers, 27 sites of active disease were detected by 67Ga citrate imaging and by SPECT/CT with an RSA. Both tracers had negative results in the other 7 patients. RSA uptake was visually lower than 67Ga uptake in 11 of the 20 patients with positive images and similar to 67Ga uptake in the other 9 patients. The only patient who did not undergo 67Ga scintigraphy underwent 99mTc-EDDA-HYNIC-TOC SPECT/CT-guided biopsy of a lung cavity with focal RSA uptake, which turned to be positive for aspergillosis. Conclusion: SPECT/CT with 99mTc-EDDA-HYNIC-TOC or 111In-DTPA-octreotide seems to be a good alternative to 67Ga citrate imaging for the evaluation of patients with systemic granulomatous disease.

  18. SPECT/CT with radiolabeled somatostatin analogues in the evaluation of systemic granulomatous infections

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Paulo Henrique Silva; Souza, Thiago Ferreira de; Moretti, Maria Luiza; Resende, Mariangela Ribeiro; Lima, Mariana da Cunha Lopes de; Santos, Allan Oliveira; Ramos, Celso Darío, E-mail: paulohsm42@gmail.com [Universidade de Campinas (UNICAMP), SP (Brazil). Escola de Medicina; Mengatti Jair [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-11-15

    Objective: To evaluate SPECT/CT with radiolabeled somatostatin analogues (RSAs) in systemic granulomatous infections in comparison with gallium-67 ({sup 67}Ga) citrate scintigraphy. Materials And Methods: We studied 28 patients with active systemic granulomatous infections, including tuberculosis, paracoccidioidomycosis, pneumocystosis, cryptococcosis, aspergillosis, leishmaniasis, infectious vasculitis, and an unspecified opportunistic infection. Of the 28 patients, 23 had started specific treatment before the study outset. All patients underwent whole-body SPECT/CT imaging: 7 after injection of {sup 99m}Tc-EDDA-HYNIC-TOC, and 21 after injection of {sup 111}In-DTPA-octreotide. All patients also underwent {sup 67}Ga citrate imaging, except for one patient who died before the {sup 67}Ga was available. Results: In 20 of the 27 patients who underwent imaging with both tracers, 27 sites of active disease were detected by {sup 67}Ga citrate imaging and by SPECT/CT with an RSA. Both tracers had negative results in the other 7 patients. RSA uptake was visually lower than {sup 67}Ga uptake in 11 of the 20 patients with positive images and similar to {sup 67}Ga uptake in the other 9 patients. The only patient who did not undergo {sup 67}Ga scintigraphy underwent {sup 99m}Tc-EDDA-HYNIC-TOC SPECT/CT-guided biopsy of a lung cavity with focal RSA uptake, which turned to be positive for aspergillosis. Conclusion: SPECT/CT with {sup 99m}Tc-EDDA-HYNIC-TOC or {sup 111}In-DTPA-octreotide seems to be a good alternative to {sup 67}Ga citrate imaging for the evaluation of patients with systemic granulomatous disease. (author)

  19. 67Ga lung scan

    International Nuclear Information System (INIS)

    Niden, A.H.; Mishkin, F.S.; Khurana, M.M.L.; Pick, R.

    1977-01-01

    Twenty-three patients with clinical signs of pulmonary embolic disease and lung infiltrates were studied to determine the value of gallium citrate 67 Ga lung scan in differentiating embolic from inflammatory lung disease. In 11 patients without angiographically proved embolism, only seven had corresponding ventilation-perfusion defects compatible with inflammatory disease. In seven of these 11 patients, the 67 Ga concentration indicated inflammatory disease. In the 12 patients with angiographically proved embolic disease, six had corresponding ventilation-perfusion defects compatible with inflammatory disease. None had an accumulation of 67 Ga in the area of pulmonary infiltrate. Thus, ventilation-perfusion lung scans are of limited value when lung infiltrates are present. In contrast, the accumulation of 67 Ga in the lung indicates an inflammatory process. Gallium imaging can help select those patients with lung infiltrates who need angiography

  20. Hybrid SPECT/CT imaging in neurology.

    Science.gov (United States)

    Ciarmiello, Andrea; Giovannini, Elisabetta; Meniconi, Martina; Cuccurullo, Vincenzo; Gaeta, Maria Chiara

    2014-01-01

    In recent years, the SPECT/CT hybrid modality has led to a rapid development of imaging techniques in nuclear medicine, opening new perspectives for imaging staff and patients as well. However, while, the clinical role of positron emission tomography-computed tomography (PET-CT) is well consolidated, the diffusion and the consequent value of single-photon emission tomography-computed tomography (SPECT-CT) has yet to be weighed, Hence, there is a need for a careful analysis, comparing the "potential" benefits of the hybrid modality with the "established" ones of the standalone machine. The aim of this article is to analyze the impact of this hybrid tool on the diagnosis of diseases of the central nervous system, comparing strengths and weaknesses of both modalities through the use of SWOT analysis.

  1. Lung hilar Ga-67 uptake in patients with lymphoma following chemotherapy.

    Science.gov (United States)

    Gunay, Emel Ceylan; Salanci, Bilge Volkan; Barista, Ibrahim; Caner, Biray

    2004-07-01

    Scintigraphic characteristics of lung hilar Ga-67 uptake (HU) and their relationship with the etiology (benign vs. malignant) of the hilar lesions in lymphoma patients following chemotherapy were retrospectively investigated. A total of 161 lymphoma patients were included in the study. The presence/absence of HU and if present, symmetry/asymmetry and intensity of HU (on the basis of a 3 scale grading system) were visually and semiquantitatively assessed on transaxial sections of thorax Ga-67 SPECT. By drawing ROIs over right and left hilum, asymmetry index (AI%) was also calculated. HU was categorized as benign or malignant depending on the radiological correlation and clinical follow-up. In the malignant group, the majority of patients (85.7%) had grade 2 or grade 3 uptake and all had asymmetric pattern. However, in the benign group, grade 1 uptake was more common (66%) and was mainly symmetric (94.6%) in appearance. AI% in the malignant group (73.7 +/- 36.6) was significantly higher than in the benign group (5.7 +/- 4.9) confirming the marked asymmetry in malignant patients.

  2. Tumor targeting using {sup 67}Ga-DOTA-Bz-folate - investigations of methods to improve the tissue distribution of radiofolates

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Cristina, E-mail: cristina.mueller@psi.ch [Center for Radiopharmaceutical Sciences ETH-PSI-USZ, Paul Scherrer Institute, 5232 Villigen-PSI (Switzerland); Vlahov, Iontcho R.; Santhapuram, Hari Krishna R.; Leamon, Christopher P. [Endocyte Inc., West Lafayette, IN 47906 (United States); Schibli, Roger [Center for Radiopharmaceutical Sciences ETH-PSI-USZ, Paul Scherrer Institute, 5232 Villigen-PSI (Switzerland); Department of Chemistry and Applied Biosciences, ETH Zurich, 8093 Zurich (Switzerland)

    2011-07-15

    Introduction: Use of folic acid radioconjugates for folate receptor (FR) targeting is a promising strategy for imaging purposes as well as for potential therapy of cancer and inflammatory diseases due to the frequent FR overexpression found on cancer cells and activated macrophages. Herein, we report on preclinical results using a novel DOTA-Bz-EDA-folate conjugate radiolabeled with [{sup 67}Ga]-gallium. Methods: DOTA-Bz-EDA-folate was prepared by conjugation of ethylenediamine-({gamma})-folate with 2-(p-isothiocyanobenzyl)-DOTA. Radiolabeling was carried out with {sup 67}GaCl{sub 3} according to standard procedures. Biodistribution studies of the tracer were performed in mice bearing FR-positive KB tumor xenografts. The effects on radiofolate biodistribution with coadministered renal uptake-blocking amino acids, diuretic agents, antifolates as well as different routes of administration were likewise investigated. Supportive imaging studies were performed using a small-animal single photon emission computed tomography (SPECT)/CT scanner. Results: {sup 67}Ga-DOTA-Bz-EDA-folate showed a high and specific accumulation in tumors (6.30%{+-}0.75% ID/g, 1 h pi and 6.08%{+-}0.89% ID/g, 4 h pi). Nonspecific radioactivity uptake in nontargeted tissues was negligible, but significant accumulation was found in FR-positive kidneys, which resulted in unfavorably low tumor-to-kidney ratios (<0.1). Coadministered amino acids or diuretics did not effectively reduce renal accumulation; in contrast, predosed pemetrexed did significantly reduce kidney uptake (<29% of control values). The SPECT/CT studies confirmed the excellent tumor-to-background contrast of {sup 67}Ga-radiofolate and the favorable reduction in kidney uptake (with improved imaging quality) resulting from pemetrexed administration. Conclusion: Conventional methods to reduce kidney uptake of radiofolates fail. However, the novel {sup 67}Ga-radiolabeled DOTA-Bz-EDA-folate can effectively be used to image FR

  3. In vivo uptake of /sup 67/Ga-citrate by an experimental abscess and the mechanism of /sup 67/Ga uptake

    Energy Technology Data Exchange (ETDEWEB)

    Nitta, Kazuo; Ogawa, Hiroshi [Daiichi Radioisotope Labs. Ltd., Tokyo (Japan); Ando, Atsushi; Ando, Itsuko; Hiraki, Tatsunosuke

    1983-10-01

    This study was undertaken to investigate the accumulation of /sup 67/Ga in an experimental abscess and to elucidate the mechanism of /sup 67/Ga uptake in the abscess. Two, three, five, seven and ten days after subcutaneous injection of 0.2 ml turpentine to the rats, /sup 67/Ga-citrate was injected to the rats. Twenty-four hours after injection of /sup 67/Ga, abscess and organs were excised and uptake rates of /sup 67/Ga were assayed. Furthermore, five days after subcutaneous injection of 0.2 ml turpentine to the rats, /sup 67/Ga-citrate was injected to the rats, at various time intervals from 10 minutes to 6 days, abscess and organs were excised and uptake rates of /sup 67/Ga were assayed. And subcellular distribution of /sup 67/Ga in abscess was determined at various time intervals after administration of /sup 67/Ga-citrate. On the other hand, to elucidate /sup 67/Ga binding substances in abscess, /sup 67/Ga-citrate and sodium sulfate-/sup 35/S were injected to the above rats, respectively. Twenty-four hours after injection, abscess was excised and homogenized. The homogenate was digested with proteinase. After digestion, the reaction mixture was gelfiltered on Sephadex G-100. Eluate samples were assayed for radioactivity, uronic acid and protein. Uptake rates of /sup 67/Ga in abscess increased with time after injection of turpentine and reached a plateau 5--7 days later./sup 67/Ga was eluted with acid mucopolysaccharides with molecular weights of 9400--40000, and with molecular weight larger than 40000. It was concluded that /sup 67/Ga was bound to the acid mucopolysaccharides (heparan sulfate, etc) in the abscess.

  4. 67Ga-emission computed tomography in bronchogenic carcinoma

    International Nuclear Information System (INIS)

    Ichiya, Yuichi; Oshiumi, Yoshihiko; Kuwabara, Yasuo; Wada, Makoto; Ayabe, Zenji; Matsuura, Keiichi

    1982-01-01

    Both conventional 67 Ga scintigraphy and 67 Ga emission computed tomography (ECT) were performed in 36 patients with bronchogenic carcinoma to evaluate clinical significance of 67 Ga-ECT as an adjunctive method. Each patient received 111 -- 185 MBq (3 -- 5 mCi) of 67 Ga-citrate intravenously. A rotation #betta# camera (Shimadzu LFOV-E) was used for ECT study, and a #betta# camera (Searle LFOV) was used for conventional scintigraphy. The detectability of 67 Ga scintigraphy with ECT in primary tumors and regional lymph node metastases was compared retrospectively with that of conventional 67 Ga scintigraphy alone. There was little improvement in detection of primary and metastatic lesions by adding 67 Ga-ECT. Only 3 primary tumors were demonstrated more distinctly by 67 Ga-ECT. However, there was no lesion which was detected only by 67 Ga-ECT. Our data indicate that inclusion of 67 Ga-ECT in the routine examination is unnecessary in cases with bronchogenic carcinoma. (author)

  5. /sup 67/Ga lung scan

    Energy Technology Data Exchange (ETDEWEB)

    Niden, A.H.; Mishkin, F.S.; Khurana, M.M.L.; Pick, R.

    1977-03-21

    Twenty-three patients with clinical signs of pulmonary embolic disease and lung infiltrates were studied to determine the value of gallium citrate /sup 67/Ga lung scan in differentiating embolic from inflammatory lung disease. In 11 patients without angiographically proved embolism, only seven had corresponding ventilation-perfusion defects compatible with inflammatory disease. In seven of these 11 patients, the /sup 67/Ga concentration indicated inflammatory disease. In the 12 patients with angiographically proved embolic disease, six had corresponding ventilation-perfusion defects compatible with inflammatory disease. None had an accumulation of /sup 67/Ga in the area of pulmonary infiltrate. Thus, ventilation-perfusion lung scans are of limited value when lung infiltrates are present. In contrast, the accumulation of /sup 67/Ga in the lung indicates an inflammatory process. Gallium imaging can help select those patients with lung infiltrates who need angiography.

  6. Diagnostic sensitivity of Tc-99m HYNIC PSMA SPECT/CT in prostate carcinoma: A comparative analysis with Ga-68 PSMA PET/CT.

    Science.gov (United States)

    Lawal, Ismaheel O; Ankrah, Alfred O; Mokgoro, Neo P; Vorster, Mariza; Maes, Alex; Sathekge, Mike M

    2017-08-01

    Emerging data from published studies are demonstrating the superiority of Ga-68 PSMA PET/CT imaging in prostate cancer. However, the low yield of the Ge-68/Ga-68 from which Gallium-68 is obtained and fewer installed PET/CT systems compared to the SPECT imaging systems may limit its availability. We, therefore, evaluated in a head-to-head comparison, the diagnostic sensitivity of Ga-68 PSMA PET/CT and Tc-99m PSMA SPECT/CT in patients with prostate cancer. A total of 14 patients with histologically confirmed prostate cancer were prospectively recruited to undergo Ga-68 PSMA PET/CT and Tc-99m HYNIC PSMA SPECT/CT. The mean age of patients was 67.21 ± 8.15 years and the median PSA level was 45.18 ng/mL (range = 1.51-687 ng/mL). SUVmax of all lesions and the size of lymph nodes with PSMA avidity on Ga-68 PSMA PET/CT were determined. Proportions of these lesions detected on Tc-99m HYNIC PSMA SPECT/CT read independent of PET/CT findings were determined. A total of 46 lesions were seen on Ga-68 PSMA PET/CT localized to the prostate (n = 10), lymph nodes (n = 24), and bones (n = 12). Of these, Tc-99m HYNIC PSMA SPECT/CT detected 36 lesions: Prostate = 10/10 (100%), lymph nodes = 15/24 (62.5%), and bones = 11/12 (91.7%) with an overall sensitivity of 78.3%. Lesions detected on Tc-99m HYNIC PSMA SPECT/CT were bigger in size (P Tc-99m HYNIC PSMA SPECT/CT. In a univariate analysis, Lymph node size (P = 0.033) and the SUVmax of all lesions (P = 0.007) were significant predictors of lesion detection on Tc-99m HYNIC PSMA SPECT/CT. Tc-99m HYNIC PSMA may be a useful in imaging of prostate cancer although with a lower sensitivity for lesion detection compared to Ga-68 PSMA PET/CT. Its use is recommended when Ga-68 PSMA is not readily available, in planning radio-guided surgery or the patient is being considered for radio-ligand therapy with Lu-177 PSMA. It performs poorly in detecting small-sized lesions hence its use is not recommended

  7. Comparisons of labeling efficiency, biological activity and biodistribution among 125I, 67Ga-DTPA- and 67Ga-DFO-lectins

    International Nuclear Information System (INIS)

    Kojima, Shuji; Jay, M.

    1987-01-01

    The labeling efficiency, biological activity and biodistribution of 125 I labeled and 67 Ga chelating agent conjugated lectins were investigated. Pisum sativum agglutinin (PSA) and Lens culinaris agglutinin (LCH) were efficiently labeled with 67 Ga using bifunctional chelating agents such as diethylenetriaminepentaacetic acid (DTPA) and deferoxamine (DFO), whereas labeling with 125 I was significantly less efficient. The agglutinating activity of these lectins towards Ehrlich ascites tumor (EAT) cells was retained on conjugation with DFO, but not with DTPA. The in vitro binding ratio of 67 Ga-DFO-lectins for EAT cells was almost the same as that of 125 I-lectins. However, the value was significantly decreased in the case of 67 Ga-DTPA-lectins. In the biodistribution study of radiolabeled lectins in Ehrlich solid tumor (EST) bearing mice, the accumulation of radioactivity in tumor tissue was very much less with 67 Ga-DTPA-lectins than with 125 I-lectins. However, the concentration was significantly elevated in the case of 67 Ga-DFO-lectins. While, these lectins accumulated in liver, spleen, lung, and kidney to a greater extent than 67 Ga citrate, the tumor to organ ratios became very low. These low tumor to organ ratios, in contrast to 67 Ga citrate, will certainly inhibit the tumor delineation, and therefore it seems that in spite of a high accumulation ratio of 67 Ga-DFO-lectins in tumor tissue, these agents are not useful in tumor detection. (orig.)

  8. 67Ga imaging in Hodgkin's disease

    International Nuclear Information System (INIS)

    Huys, J.; Schelstraete, K.; Simons, M.

    1982-01-01

    In order to answer the question if 67 Ga imaging has a practical utility for the management of the patient with Hodgkin's disease, 108 scans performed on 60 patients were reviewed. When used during the initial staging of the disease or during restaging because of recurrences, 67 Ga imaging-at least in our experience-gave many false negative results in the cervical, axillary and inguinal areas, whereas the majority of true positive scans was found at the mediastinal level (including the lower mediastinum), and also in the lung parenchyma and the upper epigastric regions. Because of its lack of sensitivity, 67 Ga imaging cannot replace other staging procedures, but nevertheless is a valuable adjunctive test, as it can identify tumor localization that may have remained undetected by other methods. Fifty-four scans were performed to monitor treatment with radiation therapy or chemotherapeutic agents. Disappearance or decreases of 67 Ga uptake after treatment usually corresponded to a disappearance or regression of the tumor as ascertained by other methods. When the treatment was shown to be ineffective, 67 Ga uptake persisted or even became more prominent. When during follow-up, a new concentration of 67 Ga appeared at the original location or elsewhere, a relapse was extremely likely. However, one must be aware of false positive images. In our material, no correlation was found between the intensity of the 67 Ga uptake and the histological subtypes of Hodgkin's disease. Neither did we observe any relation to the blood sedimentation rate or serum iron levels

  9. Ga-67 imaging in pediatric oncology

    International Nuclear Information System (INIS)

    Edeling, C.J.

    1983-01-01

    One hundred sixty-nine children suspected of having malignant disease were examined by Ga-67 scintigraphy. In 99 children with untreated diseases at the time of examination, abnormal accumulation of Ga-67 was found in 51 patients, including 40 with malignant tumor. Forty-three negative results were obtained in children with benign disorders. Five false-negative results were obtained in patients with neuroblastoma of the adrenal gland. In 70 children with malignant diseases treated before the examination, abnormal accumulation of Ga-67 was seen in 40 patients, including 38 with malignant disease and two with no clinical evidence of recurrence. Normal results were obtained in 30 patients, including 11 still suffering from malignant disease. The results of Ga-67 scintigraphy in all of the children were evaluated qualitatively. For the final diagnosis of malignant disease, diagnostic specificity was 86% and diagnostic sensitivity 79%. The prevalence of malignant disease was 56%. It is concluded that Ga-67 scintigraphy should be used for primary visualization and control of malignant tumors in children

  10. Indications for scintigraphy with 67Ga

    International Nuclear Information System (INIS)

    Plechl, S.C.; Berges, G.; Blut, J.; Bohle, H.; Gessat, C.; Hethey, B.; Linneborn, G.; Ostermann, W.; Prack, G.; Scheitza, B.

    1976-01-01

    The validity and exactness of 67 Ga scintigraphy was tested in more than 70 patients by a comparison with clinical, radiological and histological findings as well as with scintigraphs obtained with other nuclides. It was found that 67 Ga scintigraphy is a good and often even a vital supplementation to the other methods. Its main field of application, according to the authors' obervations, is the differential diagnosis of three-dimensional changes in the thorax region, in particular the diagnosis of malignant tumours of the lungs in combination with X-ray examinations. Furthermore, 67 Ga may be of use in localization diagnoses of non-malignant changes, e.g. abscesses. 67 Ga scintigraphy, which is non-hazardous and does not involve discomfort to the patients, appears to be particularly useful for course control after surgical treatment of breast cancer and for early diagnoses of metastases, provided that examination starts early enough and is repeated at regular intervals, not only in the soft parts but also in the skeleton. The question whether 67 Ga scintigraphy may be a substitute for scintigraphy with other nuclides in these fields still remains to be solved. (orig.) [de

  11. Assessment of human effective absorbed dose of 67 Ga-ECC based on biodistribution rat data.

    Science.gov (United States)

    Shanehsazzadeh, Saeed; Yousefnia, Hassan; Lahooti, Afsaneh; Zolghadri, Samaneh; Jalilian, Amir Reza; Afarideh, Hossien

    2015-02-01

    In a diagnostic context, determination of absorbed dose is required before the introduction of a new radiopharmaceutical to the market to obtain marketing authorization from the relevant agencies. In this work, the absorbed dose of [67 Ga]-ethylenecysteamine cysteine [(67 Ga)ECC] to human organs was determined by using distribution data for rats. For biodistribution data, the animals were sacrificed by CO2 asphyxiation at selected times after injection (0.5, 2 and 48 h, n = 3 for each time interval), then the tissue (blood, heart, lung, brain, intestine, feces, skin, stomach, kidneys, liver, muscle and bone) were removed. The absorbed dose was determined by Medical Internal Radiation Dose (MIRD) method after calculating cumulated activities in each organ. Our prediction shows that a 185-MBq injection of (67)Ga-ECC into the humans might result in an estimated absorbed dose of 0.029 mGy in the whole body. The highest absorbed doses are observed in the spleen and liver with 33.766 and 16.847 mGy, respectively. The results show that this radiopharmaceutical can be a good SPECT tracer since it can be produced easily and also the absorbed dose in each organ is less than permitted absorbed dose.

  12. Study of 67Ga scan in sarcoidosis

    International Nuclear Information System (INIS)

    Han Lijun; Qu Wanyin; Liu Xiuqin

    1997-01-01

    Gallium scan and serum angiotensin-converting enzyme assay (SACE) were compared in patients with sarcoidosis. The examination of 67 Ga scan, SACE determination, pulmonary function test, chest CT and chest X-ray in 24 cases with sarcoidosis were studied. The results revealed that 4 of 24 cases had obviously high uptake of 67 Ga exceeding hepatic activity (3+) in clinical active stage, 3 patients had resembling the Greek letter lambda, symmetrically located in bilateral hilar lymph nodes, and among them two had an uptake of 67 Ga in the bilateral lacrimal and parotid gland simulating 'Panda Face'. 8 of 20 cases with inactive sarcoidosis had an abnormal 67 Ga scan (1+). In those patients with normal SACE level but increased uptake of 67 Ga, active stage of disease was demonstrated and steroid therapy was indicated. Gallium scan is a valuable method for the staging of its activity and evaluation of the therapeutic effect in the follow-up patients with sarcoidosis

  13. Detectability of metastatic bone tumor by Ga-67 scintigraphy

    International Nuclear Information System (INIS)

    Koizumi, Kiyoshi; Uchiyama, Guio; Araki, Tsutomu; Hihara, Toshihiko; Ogata, Hitoshi; Monzawa, Shuichi; Kachi, Kenji; Matsusako, Masaki

    1989-01-01

    Ga-67 scintigrams in patients with malignant diseases sometimes reveal uptake of the tracer in the bone metastases. Detectability of Ga-67 scintigraphy for metastatic bone tumors and benign bone lesions was compared with that of Tc-99m bone scintigraphy. Countable bone metastases detected by bone scintigraphy were evaluated whether the lesion showed apparent, faint, or negative Ga-67 uptake. Of 47 lesions 23 (49%) showed apparent uptake and 17 (36%) showed negative uptake, only 7 (10%) mostly fracture/osteotomy, showed apparent uptake of the tracer. Uptake in the other benign lesions such as trauma of the ribs, spondylosis deformans, and arthrosis deformans was rather faint. In patients with multiple bone metastases, 9 patients (82%) out of 11 showed more prominent abnormal findings in Tc-99m MDP bone scintigraphy than in Ga-67 scintigraphy; that is, Ga-67 scintigraphy was not able to reveal all metastatic bone lesions. In patients with untreated or recurrent tumors, relation between Ga-67 uptake in the tumors and that in the bone metastases was evaluated. Of 7 patients with negative Ga-67 uptake in the bone metastases; that is, there seemed to be little relation between Ga-67 affinity to the primary tumors and that to the bone metastases. Mechanisms of the Ga-67 uptake in the bone metastases were discussed. Not only the tumor cells or tissues in the bone metastases but also bone mineral or osteoclasts might be the deposition sites of Ga-67. (author)

  14. Detectability of metastatic bone tumor by Ga-67 scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Koizumi, Kiyoshi; Uchiyama, Guio; Araki, Tsutomu; Hihara, Toshihiko; Ogata, Hitoshi; Monzawa, Shuichi; Kachi, Kenji; Matsusako, Masaki

    1989-03-01

    Ga-67 scintigrams in patients with malignant diseases sometimes reveal uptake of the tracer in the bone metastases. Detectability of Ga-67 scintigraphy for metastatic bone tumors and benign bone lesions was compared with that of Tc-99m bone scintigraphy. Countable bone metastases detected by bone scintigraphy were evaluated whether the lesion showed apparent, faint, or negative Ga-67 uptake. Of 47 lesions 23 (49%) showed apparent uptake and 17 (36%) showed negative uptake, only 7 (10%) mostly fracture/osteotomy, showed apparent uptake of the tracer. Uptake in the other benign lesions such as trauma of the ribs, spondylosis deformans, and arthrosis deformans was rather faint. In patients with multiple bone metastases, 9 patients (82%) out of 11 showed more prominent abnormal findings in Tc-99m MDP bone scintigraphy than in Ga-67 scintigraphy; that is, Ga-67 scintigraphy was not able to reveal all metastatic bone lesions. In patients with untreated or recurrent tumors, relation between Ga-67 uptake in the tumors and that in the bone metastases was evaluated. Of 7 patients with negative Ga-67 uptake in the bone metastases; that is, there seemed to be little relation between Ga-67 affinity to the primary tumors and that to the bone metastases. Mechanisms of the Ga-67 uptake in the bone metastases were discussed. Not only the tumor cells or tissues in the bone metastases but also bone mineral or osteoclasts might be the deposition sites of Ga-67.

  15. Reconsideration of the indication of Ga-67 scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Takanashi, Toshiyasu; Komatani, Akio; Yamaguchi, Koichi (Yamagata Univ. (Japan))

    1984-11-01

    In order to establish proper indication of Ga-67 scintigraphy, its actual utilization in our hospital was reviewed. Although a large number of Ga-67 scintigraphy over 500 cases a year had been done, the clinical efficacy was found in limited conditions such as small cell carcinoma of the lung, malignant lymphoma, anaplastic carcinoma of the thyroid and abscess. In the other conditions, Ga-67 scintigraphy had little significance clinically and was not effective for seeking metastasis. Based on such situations, we emphasized that the indication of Ga-67 scintigraphy should be more limited under the better understanding of its characteristics.

  16. Indications for scintigraphy with /sup 67/Ga

    Energy Technology Data Exchange (ETDEWEB)

    Plechl, S C; Berges, G; Blut, J; Bohle, H; Gessat, C; Hethey, B; Linneborn, G; Ostermann, W; Prack, G; Scheitza, B [Berufsgenossenschaftliche Krankenanstalten Bergmannsheil, Bochum (Germany, F.R.)

    1976-06-01

    The validity and exactness of /sup 67/Ga scintigraphy was tested in more than 70 patients by a comparison with clinical, radiological and histological findings as well as with scintigraphs obtained with other nuclides. It was found that /sup 67/Ga scintigraphy is a good and often even a vital supplementation to the other methods. Its main field of application, according to the authors' obervations, is the differential diagnosis of three-dimensional changes in the thorax region, in particular the diagnosis of malignant tumours of the lungs in combination with X-ray examinations. Furthermore, /sup 67/Ga may be of use in localization diagnoses of non-malignant changes, e.g. abscesses. /sup 67/Ga scintigraphy, which is non-hazardous and does not involve discomfort to the patients, appears to be particularly useful for course control after surgical treatment of breast cancer and for early diagnoses of metastases, provided that examination starts early enough and is repeated at regular intervals, not only in the soft parts but also in the skeleton. The question whether /sup 67/Ga scintigraphy may be a substitute for scintigraphy with other nuclides in these fields still remains to be solved.

  17. Determination of Ga-67 disintegration rate

    International Nuclear Information System (INIS)

    Fonseca, Katia A.; Koskinas, Maria F.; Dias, Mauro S.

    1996-01-01

    One of the consequences of the production by IPEN of new radioisotopes used in nuclear medicine, as the case of Ga-67, is the need of new standard sources of the radionuclide obtained in a fast and simple way. The Laboratorio de Metrologia de Radionuclideos at IPEN has a well-type ionization chamber system, the most suitable for this purpose. In order to calibrate this system it was necessary to standardize Ga-67 solutions by an absolute system. The present work gives details on the Ga-67 disintegration rate determination by an 4 π β-γ coincidence system, gamma spectrometry using an HPGe detector and measurements using a 1383A - type ionization chamber, in order to check the consistency in the adopted methodology. (author)

  18. High resolution study of proton resonances in 65Ga and 67Ga

    International Nuclear Information System (INIS)

    Sales, K.B.

    1980-01-01

    Differential cross sections were measured for 64 Zn(p,p) from 2.50 to 3.24 MeV and for 66 Zn(p,p) from 2.60 to 3.26 MeV at laboratory angles of 90 0 , 105 0 , 135 0 , and 160 0 . These experiments were performed with the Triangle Universities Nuclear Laboratory 3 MV Van de Graaff accelerator and associated electrostatic analyzer-homogenizer system. The total overall energy resolution was 420 to 525 eV for 64 Zn(p,p) and 360 to 405 eV for 66 Zn(p,p). Resonances observed in the excitation functions were analyzed with a multilevel R-Matrix formalism. Resonance energies, spins, parities, and elastic widths were extracted for 39 resonances in 65 Ga and 148 resonances in 67 Ga. The l = 0 proton strength functions were calculated for 64 Zn and 66 Zn. The s-wave strength function shows an increase for A=66, which is consistent with earlier results from (p,n) cross section studies. Statistical properties of the 1/2 + resonances in 65 Ga and 67 Ga were examined. The spacing and reduced width distributions were compared with the Wigner and Porter-Thomas distributions, respectively. This comparison indicates that 50% of the 1/2 + resonances were missed in 65 Ga and that 70% of the 1/2 + resonances were missed in 67 Ga. The observed s-wave level densities in 65 Ga and 67 Ga are compared with predictions from conventional level density models. The analogs of the 0.867 MeV, the 0.910 MeV, and the 1.370 MeV states of 65 Zn are observed in 65 Ga; the analogs of the 0.093 MeV and the 0.394 MeV states of 67 Zn are observed in 67 Ga. The analog states in 65 Ga were fragmented into only two or three resonances, while the two analog states in 67 Ga were highly fragmented. Fits to the fine structure distributions of these two analogs were obtained and the resulting parameters compared with the Robson model. Coulomb energies were extracted for these five analogs

  19. Tumor and liver uptake models of /sup 67/Ga-citrate

    Energy Technology Data Exchange (ETDEWEB)

    Ando, A; Ando, I; Sanada, S; Hiraki, T; Hisada, K

    1985-03-01

    After administration /sup 67/Ga concentrates with time in lysosomes from the cytoplasm of liver cells. The lysosomal role in the accumulation of /sup 67/Ga in the liver cell is weakened upon transformation of the liver cell into a malignant tumor cell. In malignant tumors (except for hepatoma) the lysosome does not play a major role in the tumor concentration of /sup 67/Ga. /sup 67/Ga is bound to acid mucopolysaccharides (keratan polysulfate, etc.) in both tumor and liver. In liver cells, large amounts of /sup 67/Ga are transported into lysosomes with these acid mucopolysaccharides, and in hepatoma cells, quite large amounts of /sup 67/Ga are transported into lysosomes with these acid mucopolysaccharides. In malignant tumor cells (except for hepatoma) the effect is much smaller, the acid mucopolysaccharides transporting very little /sup 67/Ga into lysosome. The /sup 67/Ga is concentrated in viable tumor tissue within malignant tissue but hardly at all in necrotic tumor tissue, and concentrates avidly in inflammatory infiltration around tumor cells. Plenty of /sup 67/Ga is found in liver but very little in connective tissue associated with the liver.

  20. Validity of 67Ga scintigraphy in patients with oral cancer

    International Nuclear Information System (INIS)

    Kanemura, Hironari; Kondoh, Toshirou; Hamada, Yoshiki; Nakajima, Toshifumi; Sekiya, Hideki; Ito, Ko; Sato, Junichi; Seto, Kanichi

    2003-01-01

    In this study, we investigated the diagnostic usefulness of 67 Ga scintigraphy in patients with oral cancer. Fifty-five patients with previously untreated oral cancer were administered in this study. The diagnostic accuracy of 67 Ga scintigraphy for primary cancer, cervical lymph node metastasis, systemic metastasis or double cancer were studied. The relations of the size of lesions to the diagnostic accuracy, and the degree of 67 Ga-citrate accumulation were analyzed. In addition, we discussed what makes it difficult to diagnose the lesions by using 67 Ga scintigrams. As a result, the sensitivity was 44.2% in primary cancer, 28.6% in cervical lymph node metastasis, and 25.0% in systemic metastasis or double cancer. It was suggested that 67 Ga scintigraphy is disadvantageous for the detection of small lesions. In this study, the relation between the size of lesions and the degree of 67 Ga-citrate accumulation was not clarified. The diagnostic problems of 67 Ga scintigraphy were found to be its low reliability in imaging of the lesion's localization, normal biodistribution and non-specific accumulation of 67 Ga-citrate. (author)

  1. (67/68)Ga-labeling agent that liberates (67/68)Ga-NOTA-methionine by lysosomal proteolysis of parental low molecular weight polypeptides to reduce renal radioactivity levels.

    Science.gov (United States)

    Uehara, Tomoya; Rokugawa, Takemi; Kinoshita, Mai; Nemoto, Souki; Fransisco Lazaro, Guerra Gomez; Hanaoka, Hirofumi; Arano, Yasushi

    2014-11-19

    The renal localization of gallium-67 or gallium-68 ((67/68)Ga)-labeled low molecular weight (LMW) probes such as peptides and antibody fragments constitutes a problem in targeted imaging. Wu et al. previously showed that (67)Ga-labeled S-2-(4-isothiocyanatobenzyl)-1,4,7-triazacyclononane-1,4,7-triacetic acid (SCN-Bz-NOTA)-conjugated methionine ((67)Ga-NOTA-Met) was rapidly excreted from the kidney in urine following lysosomal proteolysis of the parental (67)Ga-NOTA-Bz-SCN-disulfide-stabilized Fv fragment (Bioconjugate Chem., (1997) 8, 365-369). In the present study, a new (67/68)Ga-labeling reagent for LMW probes that liberates (67/68)Ga-NOTA-Met was designed, synthesized, and evaluated using longer-lived (67)Ga in order to reduce renal radioactivity levels. We employed a methionine-isoleucine (MI) dipeptide bond as the cleavable linkage. The amine residue of MI was coupled with SCN-Bz-NOTA for (67)Ga-labeling, while the carboxylic acid residue of MI was derivatized to maleimide for antibody conjugation in order to synthesize NOTA-MI-Mal. A Fab fragment of the anti-Her2 antibody was thiolated with iminothiolane, and NOTA-MI-Mal was conjugated with the antibody fragment by maleimide-thiol chemistry. The Fab fragment was also conjugated with SCN-Bz-NOTA (NOTA-Fab) for comparison. (67)Ga-NOTA-MI-Fab was obtained at radiochemical yields of over 95% and was stable in murine serum for 24 h. In the biodistribution study using normal mice, (67)Ga-NOTA-MI-Fab registered significantly lower renal radioactivity levels from 1 to 6 h postinjection than those of (67)Ga-NOTA-Fab. An analysis of urine samples obtained 6 h after the injection of (67)Ga-NOTA-MI-Fab showed that the majority of radioactivity was excreted as (67)Ga-NOTA-Met. In the biodistribution study using tumor-bearing mice, the tumor to kidney ratios of (67)Ga-NOTA-MI-Fab were 4 times higher (6 h postinjection) than those of (67)Ga-NOTA-Fab. Although further studies including the structure of radiometabolites and

  2. Transfer of Ga-67 from hamster dam to fetus and offspring

    International Nuclear Information System (INIS)

    Hayes, R.L.; Byrd, B.L.

    1981-01-01

    We have studied the transfer of Ga-67 from the hamster dam to the fetus and also to the postpartum offspring. During gestation the concentration of Ga-67 in the mammary glands increased by approximately 20-fold, and Ga-67 was transferred across the placenta into the fetus. The concentration of Ga-67 in the fetus decreased during the terminal stages of gestation, partly due to a decreased transfer of Ga-67 itself and partly as the result of the rapid growth of the fetus. One-day-old offspring were able to absorb from the gastrointestinal tract the Ga-67 contained in ingested dam's milk, whereas 9-day-old offspring excrete essentially all such ingested Ga-67. The Ga-67 radiation hazards to the fetus during gestation and that resulting from the transfer of Ga-67 to the newborn through ingestion of the mother's milk should receive further investigation

  3. Transfer of Ga-67 from hamster dam to fetus and offspring

    International Nuclear Information System (INIS)

    Hayes, R.L.; Byrd, B.L.

    1981-01-01

    The transfer of Ga-67 from the hamster dam to the fetus and to the postpartum offspring has been studied. During gestation the concentration of Ga-67 in the mammary glands increased by approximately 20-fold, and Ga-67 was transferred across the placenta into the fetus. The concentration of Ga-67 in the fetus decreased during the terminal stages of gestation, partly due to a decreased transfer of Ga-67 itself and partly as the result of the rapid growth of the fetus. One-day-old offspring were able to absorb from the gastrointestinal tract the Ga-67 contained in ingested dam's milk, whereas 9-day-old offspring excreted essentially all such ingested Ga-67. The Ga-67 radiation hazards to the fetus during gestation and that resulting from the transfer of Ga-67 to the newborn through ingestion of the mother's milk should receive further investigation

  4. Mechanism of tumor and liver concentration of /sup 67/Ga: /sup 67/Ga binding substances in tumor tissues and liver

    Energy Technology Data Exchange (ETDEWEB)

    Ando, A; Ando, I; Hiraki, T; Takeshita, M; Hisada, K

    1983-01-01

    Tumor-bearing animals were administered with /sup 67/Ga citrate and tumor homogenates, from which nuclear fraction was removed, and mitochondrial fraction of the host livers were digested with protease (pronase P). After digestion, the supernatants of the reaction mixtures were applied to a Sephadex G-100 column. Resultant eluates were analyzed for radioactivity, protein, uronic acid and sialic acids. Three peaks of radioactivity were obtained by gel filtration. The first peak eluted in the void volume contained a species whose molecular weight exceeded 40,000. The second peak consisted of substances with molecular weights of 9400-40,000. Radioactivity in the third peak was from liberated gallium-67. /sup 67/Ga in the second peak was bound to acid mucopolysaccharide and/or the sulfated carbohydrate chain of sulfated glycoprotein. It was thought that /sup 67/Ga in the first peak might be bound to some acid mucopolysaccharides. Considering the results of cellulose acetate electrophoresis, /sup 67/Ga in the second peak seemed to be bound to acid mucopolysaccharide which contained no uronic acids, and/or to the sulfated carbohydrate chain of sulfated glycoprotein. It was concluded that /sup 67/Ga was bound to the acid mucopolysaccharides and/or the sulfated carbohydrate chain of sulfated glycoprotein in tumor tissues and liver lysosomes.

  5. Radioimmunodetection of tumor with Ga-67 labeled antibodies

    International Nuclear Information System (INIS)

    Furukawa, Takako; Endo, Keigo; Ohmomo, Yoshiro

    1986-01-01

    Antibodies against tumor associated antigen; anti-AFP polyclonal antibody, anti-thyroglobulin monoclonal antibody and anti-hCG monoclonal antibody, were labeled with Ga-67, using deferoxamine (DF) as a bifunctional chelating agent. The immunoreactivity and in vivo stability of the Ga-67 labeled antibodies were examined. The effect of DF conjugation to antibodies on the antigen-binding activity was evaluated by RIA and Scatchard analysis or tanned sheep red blood cell hemagglutination technique. When DF was conjugated to antibody at the molar ratio of 1 : 1, the antibody activity of the DF-conjugated antibodies was fully retained. Whereas, in heavily conjugated antibodies, the maximum antigen binding capacity was reduced. Biodistribution study in normal mice demonstrated the high in vivo stability of Ga-67 labeled antibodies. The labeling of DF-antibody conjugated with Ga-67 was performed easily and quickly, with a high labeling efficiency, requiring no further purification. Thus, this labeling method, providing in vivo stability of Ga-67 labeled antibody and full retention of immunoreactivity, would be useful for the radioimmunodetection of various cancers. (author)

  6. 67Ga-citrate incorporation and DNA synthesis in tumors

    International Nuclear Information System (INIS)

    Hammersley, P.A.G.; Taylor, D.M.

    1975-01-01

    The results obtained in these studies suggest that in the tumors studied there is some form of relationship between 67 Ga uptake and the rate of DNA synthesis. However, the observations in the HP melanoma, in which small tumors showed a negative correlation between 67 Ga uptake and rate of DNA synthesis and larger tumors showed a positive correlation, coupled with the virtually constant uptake of 67 Ga over a wide range of rates of DNA synthesis in the drug- and radiation-treated tumors, suggest that the uptake of the radionuclide is not simply related to the rate of DNA synthesis per se. Studies in embryonic mouse tissues suggested that 67 Ga uptake was not related to the rate of DNA synthesis and regenerating liver does not show a greater 67 Ga uptake than normal liver. Phytohemagglutinin-treated human lymphocytes show increased 67 Ga uptake compared to unstimulated lymphocytes, and it has been suggested that this is related to the stimulus to divide rather than to events occurring in a specific phase of the cell cycle. This suggests that proliferating cells may exhibit membrane changes which either result in increased transport of 67 Ga into the cell or permit a greater degree of binding of the radionuclide to the cell membrane than can occur in resting cells. The membrane-binding hypothesis is supported by the observations on phytohemagglutinin-stimulated lymphocytes but not by observations of the subcellular distribution of 67 Ga in these tumors which confirm the suggestion that the radionuclide is concentrated in lysosomes. Thus it appears that although in tumor cells, at least, there is some correlation between 67 Ga uptake and the rate of DNA synthesis and hence by implication of cell proliferation, the nature of this link remains obscure, and more detailed studies are needed to increase our understanding of the relationship

  7. Clinical applications of SPECT/CT: New hybrid nuclear medicine imaging system

    International Nuclear Information System (INIS)

    2008-08-01

    Interest in multimodality imaging shows no sign of subsiding. New tracers are spreading out the spectrum of clinical applications and innovative technological solutions are preparing the way for yet more modality marriages: hybrid imaging. Single photon emission computed tomography (SPECT) has enabled the evaluation of disease processes based on functional and metabolic information of organs and cells. Integration of X ray computed tomography (CT) into SPECT has recently emerged as a brilliant diagnostic tool in medical imaging, where anatomical details may delineate functional and metabolic information. SPECT/CT has proven to be valuable in oncology. For example, in the case of a patient with metastatic thyroid cancer, neither SPECT nor CT alone could identify the site of malignancy. SPECT/CT, a hybrid image, precisely identified where the surgeon should operate. However SPECT/CT is not just advantageous in oncology. It may also be used as a one-stop-shop for various diseases. Clinical applications with SPECT/CT have started and expanded in developed countries. It has been reported that moving from SPECT alone to SPECT/CT could change diagnoses in 30% of cases. Large numbers of people could therefore benefit from this shift all over the world. This report presents an overview of clinical applications of SPECT/CT and a relevant source of information for nuclear medicine physicians, radiologists and clinical practitioners. This information may also be useful for decision making when allocating resources dedicated to the health care system, a critical issue that is especially important for the development of nuclear medicine in developing countries. In this regard, the IAEA may be heavily involved in the promotion of programmes aimed at the IAEA's coordinated research projects and Technical Cooperation projects

  8. Various factors affecting /sup 67/Ga scintigraphy of liver cancer

    Energy Technology Data Exchange (ETDEWEB)

    Motoki, T; Morinari, H; Oono, K [Tokyo Univ. (Japan). Faculty of Medicine

    1980-10-01

    Various factors affecting /sup 67/Ga accumulation in liver cancer were studied in 38 patients with liver cancer (19 with hepatocellular carcinoma and 19 with metastatic liver cancer) who had received /sup 67/Ga-scintigraphy and liver scintigraphy. Besides histological types, the size, necrosis, vascularity and treatments of liver cancer, concentrations of transferrin (/sup 67/Ga binding protein) and iron in blood probably affected /sup 67/Ga accumulation in liver cancer.

  9. Interest of hybrid SPECT-CT imaging for diagnosis of infection

    International Nuclear Information System (INIS)

    Riviere, A.; Farid, K.; Guyot, M.; Jeandot, R.; Allard, M.; Fernandez, P.; Clermont, H. de; Dauchy, F.; Dupon, M.; Fernandez, P.

    2008-01-01

    Single-Photon Emission Computed Tomography-Computerized Tomography (SPECT-CT) is a new hybrid technique which offers new diagnostic capabilities in daily nuclear medicine practice. This technique not only allows to acquire merged anatomic and functional images in the same time, but also, it increases sensitivity and accuracy of SPECT thanks to attenuation and scattering corrections got from transmission data. Until now, SPECT-CT data have been mainly obtained in oncology and cardiology, but now, many authors use it in many scan studies and particularly for infectious diseases. In inflammatory bowel diseases, SPECT-CT seems to increase diagnostic performances and to modify management of many patients. In suspected vascular sepsis, SPECT-CT could increase sensitivity of white blood cell scintigraphy but also its specificity thanks to spatial resolution of CT. In osteo-articular sepsis, SPECT-CT has the advantage to distinguish osteomyelitis from soft tissue infection and to guide biopsies. Nevertheless, in the light of PET-CT works, SPECT-CT development will probably modify nuclear medicine practice and many studies have to be conducted to highlight consensual procedure guidelines. (authors)

  10. Accumulation mechanism of 67Ga-citrate into malignant tumor

    International Nuclear Information System (INIS)

    Yamada, Norihisa

    1988-01-01

    In an attempt to explore the accumulation mechanism of Ga-67 in malignant tumors, the role of lysosomes was examined in tumor-bearing mice. Both Ga-67 and Sc-46 radioactivities in the lysosomal fraction were measured by the well type scintilation counter. The disruption of lysosome did not occur in the process of the fractionation procedures because Sc-46 was readily taken up by the lysosome of tumor cells. A large quantity of Ga-67 was taken up by the tumor cytosol and a small quantity was taken up by the tumor lysosome. Both of the nuclides were readily taken up by the liver, with almost the same accumulation rates. Ga-67 was bound to acid mucopolysaccharide with a molecular weight of 10,000 dalton, while Sc-46 was bound to acid mucopolysaccharide whose molecular weight exceeds 40,000 dalton. Lysosomal accumulation in tumor tissues depended on binding substances of these nuclides in tissues. Lysosome did not play an important role in the tumor accumulation of Ga-67. Ga-67 is taken up by tumor tissues and connective tissues, and is bound to acid mucopolysaccharide in these tissues. (Namekawa, K)

  11. Chilaiditi's syndrome demonstrated by SPECT/CT

    Directory of Open Access Journals (Sweden)

    Nalini S Perumal

    2009-11-01

    Full Text Available Purpose: Chilaiditi’s syndrome is a rare condition commonly diagnosed as an incidental radiological finding. The aim of this report is to show the role of SPECT-CT in this syndrome and state the functional and anatomical role of this hybrid imaging modality. Materials and Methods: A case report. Results: A 49-year-old female patient was referred for gallium-67 citrate for a possible granulomatous myositis and underwent SPECT-CT of the abdomen to assess the area of decreased gallium uptake on planar images of the liver. The combined SPECT and CT modality demonstrated findings consistent with the clinical evidence of Chilaiditi’s syndrome. The anatomical part of this hybrid modality made it easier to evaluate the area of gallium lack of uptake which was due to air in the colon. Conclusion: This case does not only show the role of SPECT-CT in this syndrome but also suggest that the use of such modality should be considered whenever available in the evaluation of patients in whom the localization of active disease becomes imperative.

  12. Renal Localization of 67Ga Citrate in Noninfectious Nephritis

    International Nuclear Information System (INIS)

    Lee, Kang Wook; Jeong, Min Soo; Rhee, Sunn Kgoo; Kim, Sam Yong; Shin, Young Tai; Ro, Heung Kyu

    1992-01-01

    67 Ga citrate scan has been requested for detection or follow-up of inflammatory or neoplastic disease. Visualization of 67 Ga citrate in the kidneys at 48 and 72 hr post injection is usually interpreted as evidence of renal pathology. But precise mechanisms of abnormal 67 Ga uptake in kidneys were unknown. We undertook a study to determine the clinical value of 67 Ga citrate imaging of the kidneys in 68 patients with primary or secondary nephropathy confirmed by renal biopsy and 66 control patients without renal disease. Renal uptake in 48 to 72 hr images was graded as follows: Grade 0=background activity;1=faint uptake greater than background; 2=definite uptake, but less than lumbar vertebrae;3 same uptake as lumbar vertebrae, but less than liver; 4=same or higher uptake than liver. The results were as follows. 1) 42 of 68(62%) patients with noninfectious nephritis showed grade 2 or higher 67 Ga renal uptake but only 10 percent of control patients showed similar uptake. 2) In 14 patients with systemic lupus erythematosus, 8 of 9 (89%) patients with lupus nephritis exhibited marked renal uptake. 3) 36 of 41 patients (88%) with combined nephrotic syndrome showed Grade 2 or higher renal uptake. 4) Renal 67 Ga uptake was correlated with clinical severity of nephrotic syndrome determined by serum albumin level, 24 hr urine protein excretion and serum lipid levels. 5) After complete remission of nephrotic syndrome, renal uptake in all 8 patients who were initially Grade 3 or 4, decreased to Grade 1 or 0. In conclusion, we think that the mechanism of renal 67 Ga uptake in nephrotic syndrome might be related to the pathogenesis of nephrotic syndrome. In systemic lupus erythematosus, 67 Ga citrate scan is useful in predicting renal involvement.

  13. Comparison of hybrid {sup 68}Ga-PSMA-PET/CT and {sup 99m}Tc-DPD-SPECT/CT for the detection of bone metastases in prostate cancer patients. Additional value of morphologic information from low dose CT

    Energy Technology Data Exchange (ETDEWEB)

    Janssen, Jan-Carlo; Meissner, Sebastian; Diederichs, Gerd; Hamm, Bernd; Makowski, Marcus R. [Charite, Department of Radiology, Berlin (Germany); Woythal, Nadine; Prasad, Vikas; Brenner, Winfried [Charite, Department of Nuclear Medicine, Berlin (Germany)

    2018-02-15

    This study compared {sup 68}Gallium-prostate-specific-membrane-antigen based Positron-emission-tomography ({sup 68}Ga-PSMA-PET) and {sup 99metastable}technetium-3,3-diphospho-1,2-propanedicarbonacid ({sup 99m}Tc-DPD-SPECT) in performing skeletal staging in prostate cancer (PC) patients and evaluated the additional value of the information from low-dose-computed tomography (CT). In this retrospective study, 54 patients who received {sup 68}Ga-PSMA-PET/CT and {sup 99m}Tc-DPD-SPECT/CT within 80 days were extracted from our database. Osseous lesions were classified as benign, malignant or equivocal. Lesion, region and patient based analysis was performed with and without CT fusion. The reference standard was generated by defining a best valuable comparator (BVC) containing information from all available data. In the patient based analysis, accuracies measured as ''area-under-the-curve'' (AUC) for {sup 68}Ga-PSMA-PET, {sup 99m}Tc-SPECT, {sup 68}Ga-PSMA-PET/CT and {sup 99m}Tc-SPECT/CT were 0.97-0.96, 0.86-0.83, 1.00 and 0.83, respectively (p<0.05) (ranges = optimistic vs. pessimistic view). Region based analysis resulted in the following sensitivities and specificities: 91.8-97.7%, 100-99.5% (PET); 61.2-70.6%, 99.8-98.3% (SPECT); 97.7%, 100% (PET/CT), 69.4% and 98.3% (SPECT/CT) (p<0.05). The amount of correct classifications of equivocal lesions by CT was significantly higher in PET (100%) compared to SPECT (52.4%) (p<0.05). {sup 68}Ga-PSMA-PET outperforms {sup 99m}Tc-DPD-SPECT in detecting bone metastases in PC patients. Additional information from low-dose-CT resulted in a significant reduction in equivocal lesions in both modalities, however {sup 68}Ga-PSMA-PET benefited most. (orig.)

  14. Scintiscanning of lung cancer with 67Ga-citrate

    International Nuclear Information System (INIS)

    Abe, Mitsunobu; Ohyama, Shiro; Ohtsuka, Hassau; Hoshina, Toshifumi; Takanashi, Shuko

    1982-01-01

    The clinical value of scintigram with 67 Ga-citrate in 58 patients with primary lung cancer was investigated and discussed. The results are as follows: 1) Positive 67 Ga-scintigram was obtained in 83% of patients with primary lung cancer. The histologically confirmed positive ratios were 74% in adenocarcinoma, 94% in squamous cell carcinoma, 80% in small cell carcinoma and 100% in large cell carcinoma. 2) The positive ratios according to T category of TNM classification was 0% (0/1) in T1, 83% (20/24) in T2 and 85% (28/33) in T3. 3) According to rules for classification of lung cancer (TNM UICC 1978,) T2 cases were divided into two groups. a) In patients with hilar involvements on chest X-ray, positive accumulation to the hilar region was 88% (7/8). b) In patients without the evidence of hilar involvements on chest X-ray, the positive accumulation to the hilar region was 81% (13/16). 4) All cases extending to the mediastinum showed abnormal 67 Ga-citrate accumulation regardless of histological type. 67 Ga-citrate scanning is useful in evaluating the extent of lung cancer, especially with hilar and mediastinal involvements. Therefore 67 Ga-citrate scanning seems to be very useful for planning the radiotherapy for lung cancer. (author)

  15. Hybrid SPECT/CT: Principle, dosimetry and quality control

    International Nuclear Information System (INIS)

    Hapdey, S.; Gardin, I.; Salles, A.; Rousseliere, F.; Edet-Sanson, A.; Vera, P.

    2009-01-01

    The recent introduction of hybrid systems combining a SPECT and a CT in nuclear medicine, greatly improved the diagnostic accuracy for particular clinical indications, due to the possible attenuation and/or scatter correction of the SPECT functional images and the availability of helpful anatomic information. Although the gamma cameras performances are noticeably comparable, the associated CT furnished by the manufacturer are relatively different from each other. Whatever the system is, the introduction of CT in the nuclear diagnostic process results in a significant increase of the patient dose. This dose increase should be justified and optimized considering both the clinical question and the CT settings available on these systems. The installation of a hybrid system must be accompanied by the management of a documentary quality insurance program, jointly developed by the technologists, physicists and physicians, both covering its clinical use and the associated dosimetry issues as monitoring its performances. Particular quality control procedures have to be defined because of the coupling between the two devices. (authors)

  16. Validity of {sup 67}Ga scintigraphy in patients with oral cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kanemura, Hironari; Kondoh, Toshirou; Hamada, Yoshiki; Nakajima, Toshifumi; Sekiya, Hideki; Ito, Ko; Sato, Junichi; Seto, Kanichi [Tsurumi Univ., Yokohama (Japan). School of Dental Medicine

    2003-03-01

    In this study, we investigated the diagnostic usefulness of {sup 67}Ga scintigraphy in patients with oral cancer. Fifty-five patients with previously untreated oral cancer were administered in this study. The diagnostic accuracy of {sup 67}Ga scintigraphy for primary cancer, cervical lymph node metastasis, systemic metastasis or double cancer were studied. The relations of the size of lesions to the diagnostic accuracy, and the degree of {sup 67}Ga-citrate accumulation were analyzed. In addition, we discussed what makes it difficult to diagnose the lesions by using {sup 67}Ga scintigrams. As a result, the sensitivity was 44.2% in primary cancer, 28.6% in cervical lymph node metastasis, and 25.0% in systemic metastasis or double cancer. It was suggested that {sup 67}Ga scintigraphy is disadvantageous for the detection of small lesions. In this study, the relation between the size of lesions and the degree of {sup 67}Ga-citrate accumulation was not clarified. The diagnostic problems of {sup 67}Ga scintigraphy were found to be its low reliability in imaging of the lesion's localization, normal biodistribution and non-specific accumulation of {sup 67}Ga-citrate. (author)

  17. Evaluation of in vivo stability of Ga-67 labeled human fibrinogen

    International Nuclear Information System (INIS)

    Takahashi, Keietsu; Takahashi, Jun; Okano, Sakae; Kurami, Miki; Ueda, Nobuo; Hazue, Masaaki

    1987-01-01

    Human fibrinogen (Fib) was conjugated with a large number of deferoxamine (DFO) through dialdehyde starch (DAS), and the conjugate (Fib-DAS-DFO) was labeled with Ga-67. Thus labeled fibrinogen (Ga-67-Fib-DAS-DFO) showed a high labeling efficiency (more than 90 %) and retained clottability (more than 80 %). For the evaluation of plasma radioactive species, blood samples were collected at various time periods after the i.v. administration of Ga-67-Fib-DAS-DFO into rats, and the plasma radioactivity was analyzed by high performance liquid chromatography (HPLC) and electrophoresis (EP). The radioactive HPLC elution profiles for the plasma samples were identical with that of the original Ga-67-Fib-DAS-DFO; the EP patterns for the plasma were also identical with the original one, and no radioactive species, except for Ga-67-Fib-DAS-DFO, was detected by HPLC or EP. Furthermore, the presence of transferrin in the labeling formulation did not affect the labeling yield of Ga-67-Fib-DAS-DFO indicating that the transchelation of Ga-67 from DFO on Fib to transferrin is negligible. These findings indicated that Ga-67 is tightly bound to Fib-DAS-DFO in blood, and the Ga-67-Fib-DAS-DFO can be efficiently trapped by clots as the result of its high retention of physiological activities as fibrinogen. (author)

  18. A promising hybrid approach to SPECT attenuation correction

    International Nuclear Information System (INIS)

    Lewis, N.H.; Faber, T.L.; Corbett, J.R.; Stokely, E.M.

    1984-01-01

    Most methods for attenuation compensation in SPECT either rely on the assumption of uniform attenuation, or use slow iteration to achieve accuracy. However, hybrid methods that combine iteration with simple multiplicative correction can accommodate nonuniform attenuation, and such methods converge faster than other iterative techniques. The authors evaluated two such methods, which differ in use of a damping factor to control convergence. Both uniform and nonuniform attenuation were modeled, using simulated and phantom data for a rotating gamma camera. For simulations done with 360 0 data and the correct attenuation map, activity levels were reconstructed to within 5% of the correct values after one iteration. Using 180 0 data, reconstructed levels in regions representing lesion and background were within 5% of the correct values in three iterations; however, further iterations were needed to eliminate the characteristic streak artifacts. The damping factor had little effect on 360 0 reconstruction, but was needed for convergence with 180 0 data. For both cold- and hot-lesion models, image contrast was better from the hybrid methods than from the simpler geometric-mean corrector. Results from the hybrid methods were comparable to those obtained using the conjugate-gradient iterative method, but required 50-100% less reconstruction time. The relative speed of the hybrid methods, and their accuracy in reconstructing photon activity in the presence of nonuniform attenuation, make them promising tools for quantitative SPECT reconstruction

  19. 67Ga scanning and upper gastrointestinal series for gastric lymphomas

    International Nuclear Information System (INIS)

    Ichiya, Y.; Oshiumi, Y.; Kamoi, I.; Imoto, T.; Shimoda, Y.; Kitagawa, S.; Matsuura, K.

    1982-01-01

    67 Ga scanning and upper gastrointestinal (UGI) series were performed in 13 patients with gastric lymphomas before any treatment was initiated. Seven of these patients also underwent both examinations after completing chemotherapy and/or radiation therapy. Prior to treatment, all 13 patients had abnormalities on the UGI examination, and 12 of them had abnormalities on the 67 Ga scans. In 6 patients, more extensive gastric abnormalities were demonstrated by 67 Ga scanning than by UGI examination. Although persistent 67 Ga uptake after treatment was indicative of relatively poor therapeutic response, lack of uptake did not always indicate a good response to treatment

  20. Whole-body /sup 67/Ga scintigraphy in dermatomyositis

    Energy Technology Data Exchange (ETDEWEB)

    Hiraki, Yoshio; Okazaki, Yoshio; Murakami, Kiminori; Inoue, Nobuhiro; Noriyasu, Toshiaki; Takeda, Yoshihiro; Morimoto, Setsuo; Aono, Kaname

    1987-10-01

    The presence or absence of abnormal accumulation of gallium-67 in soft tissues was studied in 11 patients undergoing /sup 67/Ga scintigraphy out of 25 patients with dermatomyositis and polymyositis (DM-PM) who had visited our hospital during the period between July 1981 and March 1987 and met the diagnostic criteria of muscle biopsy, etc. A definite image of abnormal accumulation was obtained by /sup 67/Ga scintigraphy in 3 of the patients. Although the positive site tended to be in agreement with the site of muscular symptoms in the DM-PM active stage, the accumulation was not necessarily correlated with the variations in creatine phosphokinase. From these results, it seems necessary to keep in mind the possibility that gallium-67 may also accumulate abnormally in the soft tissue lesion owing to the pathogenic process specific to DM-PM when /sup 67/Ga scintigraphy is undertaken for the purpose of screening, etc., for complication by a malignant tumor in DM-PM patients

  1. Radiation effect on 67Ga retention and distribution in mouse tissues

    International Nuclear Information System (INIS)

    Mainwaring, H.R.; Swartzendruber, D.C.; Lushbaugh, C.C.; Idoyaga-Vargas, N.L.; Watson, E.E.

    1976-01-01

    We have studied the effect of external x irradiation on the whole-body retention and tissue distribution of gallium-67 ( 67 Ga) in mice over a period of 20 days. Adult male C57BL/6 Cum mice were injected intraperitoneally with 5 μCi 67 Ga 24 hr before, immediately before, immediately after, or 24 hr after whole-body x-ray exposure to 450 R. Control mice received 67 Ga injections and sham irradiation. Increased excretion and reduced soft-tissue concentrations of 67 Ga occurred in irradiated mice. The greatest effect was observed when the radionuclide was injected 24 hr after irradiation and assayed 24 hr later. An analysis of variance of the retention data showed that the differences between the groups were significant at the 99 percent confidence level. Exponential least-squares analysis of whole-body counting results revealed three compartments in the biological retention data. The long-lived compartment possibly corresponds to 67 Ga bound relatively tightly in certain body tissues and lost slowly. The two remaining compartments have been tentatively identified as circulating unbound 67 Ga that is lost rapidly and circulating bound 67 Ga that is lost less rapidly

  2. Biological behaviour of some 67Ga and 64Cu chelates

    International Nuclear Information System (INIS)

    Leonovicova, T.; Angelis, B.; Cifka, J.; Cifkova, I.

    1984-01-01

    Chelates of 67 Ga and 64 Cu with iminodiacetic acid (IDA) and its two phenyl derivatives as well as with nitrilotriacetic acid (NTA) and benzylnitrilotriacetic acid (BNTA) were prepared. All the chelates were found to be negatively charged. A study of the biological distribution of these chelates in rats during time intervals of 3 to 180 min showed that the chelate of 67 Ga with IDA substituted at a phenyl by a hydrophobic substituent is excreted by the kidneys into the urine at a much higher rate than the IDA chelate of 67 Ga. The excretion of NTA and BNTA chelates of 67 Ga is the opposite. Blood clearance of 64 Cu chelates is more rapid than that of 67 Ga chelates. Chelates of 64 Cu accumulate in the liver and with the bile are slowly excreted into the intestines, urinary excretion is negligible. (author)

  3. 67Ga-citrate scanning in gastrointestinal malignancies

    International Nuclear Information System (INIS)

    Douds, H.N.; Berens, S.V.; Long, R.F.; Caplan, G.E.

    1978-01-01

    The value of 67 Ga-citrate scanning in cases of gastrointestinal malignancies is discussed. Seven cases are presented, including lymphomas of the stomach, small bowel, and rectum, and adenocarcinomas of the stomach and colon. In a review of the literature, there is general pessimism regarding the use of 67 Ga scans in GI malignancies. Based on previous reports and our own experience, specific clinical situations are cited in which the scan is of considerable value for diagnosis and followup of GI malignancy

  4. Localization of thrombi using the Ga-67-DFO-DAS fibrinogen

    International Nuclear Information System (INIS)

    Takahashi, Eriko; Ohta, Yoshiko; Kawasaki, Sachiko; Maki, Masako; Hiroe, Michiaki; Kusakabe, Kiyoko; Kohno, Atsushi; Shigeta, Akiko

    1985-01-01

    This report shows demonstrable thrombus imaging with Ga-67-DFO-DAS fibrinogen in a patient with Marfan's syndrome. Significant Ga-67-DFO-DAS fibrinogen deposition was noted in the leakage surrounding replased graft of ascending aorta and lesion of pulmonary parenchyma which was suspicious of pulmonary infarction. This results promises that Ga-67-DFO-DAS fibrinogen is a useful tool for evaluation of the clotting under various forms of therapy. (author)

  5. Renal Localization of {sup 67}Ga Citrate in Noninfectious Nephritis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kang Wook; Jeong, Min Soo; Rhee, Sunn Kgoo; Kim, Sam Yong; Shin, Young Tai; Ro, Heung Kyu [Chungnam University College of Medicine, Deajeon (Korea, Republic of)

    1992-07-15

    {sup 67}Ga citrate scan has been requested for detection or follow-up of inflammatory or neoplastic disease. Visualization of {sup 67}Ga citrate in the kidneys at 48 and 72 hr post injection is usually interpreted as evidence of renal pathology. But precise mechanisms of abnormal {sup 67}Ga uptake in kidneys were unknown. We undertook a study to determine the clinical value of {sup 67}Ga citrate imaging of the kidneys in 68 patients with primary or secondary nephropathy confirmed by renal biopsy and 66 control patients without renal disease. Renal uptake in 48 to 72 hr images was graded as follows: Grade 0=background activity;1=faint uptake greater than background; 2=definite uptake, but less than lumbar vertebrae;3 same uptake as lumbar vertebrae, but less than liver; 4=same or higher uptake than liver. The results were as follows. 1) 42 of 68(62%) patients with noninfectious nephritis showed grade 2 or higher {sup 67}Ga renal uptake but only 10 percent of control patients showed similar uptake. 2) In 14 patients with systemic lupus erythematosus, 8 of 9 (89%) patients with lupus nephritis exhibited marked renal uptake. 3) 36 of 41 patients (88%) with combined nephrotic syndrome showed Grade 2 or higher renal uptake. 4) Renal {sup 67}Ga uptake was correlated with clinical severity of nephrotic syndrome determined by serum albumin level, 24 hr urine protein excretion and serum lipid levels. 5) After complete remission of nephrotic syndrome, renal uptake in all 8 patients who were initially Grade 3 or 4, decreased to Grade 1 or 0. In conclusion, we think that the mechanism of renal {sup 67}Ga uptake in nephrotic syndrome might be related to the pathogenesis of nephrotic syndrome. In systemic lupus erythematosus, {sup 67}Ga citrate scan is useful in predicting renal involvement.

  6. Ga-67 uptake post cesarean section

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, O.L.; Maisano, E.R.

    1984-02-01

    Gallium-67 distribution in normal patients is well known; it is also known that the concentration in some tissues may vary according to an individual physiologic stimulus. In this report, the case of a young woman is presented who was studied 15 days after a cesarean section and showed physiologic and pathologic Ga-67 accumulation.

  7. Ga-67 uptake post cesarean section

    International Nuclear Information System (INIS)

    Lopez, O.L.; Maisano, E.R.

    1984-01-01

    Gallium-67 distribution in normal patients is well known; it is also known that the concentration in some tissues may vary according to an individual physiologic stimulus. In this report, the case of a young woman is presented who was studied 15 days after a cesarean section and showed physiologic and pathologic Ga-67 accumulation

  8. Retention and subcellular distribution of 67Ga in normal organs

    International Nuclear Information System (INIS)

    Ando, A.; Ando, I.; Hiraki, T.

    1986-01-01

    Using normal rats, retention values and subcellular distribution of 67 Ga in each organ were investigated. At 10 min after administration of 67 Ga-citrate the retention value of 67 Ga in blood was 6.77% dose/g, and this value decreased with time. The values for skeletal muscle, lung, pancreas, adrenal, heart muscle, brain, small intestine, large intestine and spinal cord were the highest at 10 min after administration, and they decreased with time. Conversely this value in bone increased until 10 days after injection. But in the liver, kidney, and stomach, these values increased with time after administration and were highest 24 h or 48 h after injection. After that, they decreased with time. The value in spleen reached a plateau 48 h after administration, and hardly varied for 10 days. From the results of subcellular fractionation, it was deduced that lysosome plays quite an important role in the concentration of 67 Ga in small intestine, stomach, lung, kidney and pancreas; a lesser role in its concentration in heart muscle, and hardly any role in the 67 Ga accumulation in skeletal muscle. In spleen, the contents in nuclear, mitochrondrial, microsomal, and supernatant fractions all contributed to the accumulation of 67 Ga. (orig.) [de

  9. Influences of reconstruction and attenuation correction in brain SPECT images obtained by the hybrid SPECT/CT device: evaluation with a 3-dimensional brain phantom

    International Nuclear Information System (INIS)

    Akamatsu, Mana; Yamashita, Yasuo; Akamatsu, Go; Tsutsui, Yuji; Ohya, Nobuyoshi; Nakamura, Yasuhiko; Sasaki, Masayuki

    2014-01-01

    The aim of this study was to evaluate the influences of reconstruction and attenuation correction on the differences in the radioactivity distributions in 123 I brain SPECT obtained by the hybrid SPECT/CT device. We used the 3-dimensional (3D) brain phantom, which imitates the precise structure of gray matter, white matter and bone regions. It was filled with 123 I solution (20.1 kBq/mL) in the gray matter region and with K 2 HPO 4 in the bone region. The SPECT/CT data were acquired by the hybrid SPECT/CT device. SPECT images were reconstructed by using filtered back projection with uniform attenuation correction (FBP-uAC), 3D ordered-subsets expectation-maximization with uniform AC (3D-OSEM-uAC) and 3D OSEM with CT-based non-uniform AC (3D-OSEM-CTAC). We evaluated the differences in the radioactivity distributions among these reconstruction methods using a 3D digital phantom, which was developed from CT images of the 3D brain phantom, as a reference. The normalized mean square error (NMSE) and regional radioactivity were calculated to evaluate the similarity of SPECT images to the 3D digital phantom. The NMSE values were 0.0811 in FBP-uAC, 0.0914 in 3D-OSEM-uAC and 0.0766 in 3D-OSEM-CTAC. The regional radioactivity of FBP-uAC was 11.5% lower in the middle cerebral artery territory, and that of 3D-OSEM-uAC was 5.8% higher in the anterior cerebral artery territory, compared with the digital phantom. On the other hand, that of 3D-OSEM-CTAC was 1.8% lower in all brain areas. By using the hybrid SPECT/CT device, the brain SPECT reconstructed by 3D-OSEM with CT attenuation correction can provide an accurate assessment of the distribution of brain radioactivity

  10. Positive imaging of venous thrombi and thromboemboli with Ga-67 DFO-DAS-fibrinogen

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Kazutaka; Senda, Michio; Fujita, Toru; Yonekura, Yoshiharu; Kumada, Kaoru; Yokoyama, Akira; Torizuka, Kanji

    1988-05-01

    A newly developed thrombus imaging agent, /sup 67/Ga-DFO-DAS-fibrinogen (/sup 67/Ga-fibrinogen), was used for 22 studies in 20 cases of suspected deep venous thrombosis. Increased accumulation of /sup 67/Ga-fibrinogen in venous thrombi was depicted at 48 h after injection in 10 of the 15 cases (10 of 17 studies) who showed abnormal findings in radionuclide venography. A hot spot in the lung emboli was visualized in two cases. Seven of the eight cases having anticoagulant therapy showed increased /sup 67/Ga-fibrinogen uptake, while follow-up /sup 67/Ga-fibrinogen scintigraphy after the administration of heparin and urokinase did not reveal an abnormal hot spot in one case. /sup 67/Ga-fibrinogen can be made available simply by adding /sup 67/Ga solution to a vial containing fibrinogen-DAS-DFO conjugate. In conclusion, /sup 67/Ga-fibrinogen is considered to be a promising agent for detecting active venous thrombi and to assess the effect of anticoagulant therapy.

  11. In vitro binding of 67Ga to Ehrlich ascites tumor cells

    International Nuclear Information System (INIS)

    Kojima, S.; Kubodera, A.

    1984-01-01

    The binding of 67 Ga to Ehrlich ascites tumor cells (ETC) was studied in vitro. Acid mucopolysaccharide (AMPS) present at the cell surface of ETC was identified as heparan sulfate (HS). The extent of 67 Ga binding to ETC reached a plateau (ca. 10% of the added dose) at 1-2 h after the start of incubation. The binding was higher under neutral or alkaline conditions than under acidic conditions. Heparin and heparitinase treatment both significantly decreased the extent of 67 Ga binding to ETC. Mild treatment with protease, including trypsin or papain, also decreased the binding. On the contrary, the treatment with trypsin under severe conditions markedly increased the extent of 67 Ga binding to ETC. These results support the hypothesis that HS plays an important role as a 67 Ga receptor in the mechanism of gallium binding to ETC. (orig.)

  12. Diagnosis of thyroid lymphoma and follow-up evaluation using Ga-67 scintigraphy

    International Nuclear Information System (INIS)

    Nishiyama, Yoshihiro; Yamamoto, Yuka; Yokoe, Koiku; Satoh, Katashi; Ohkawa, Motoomi

    2003-01-01

    A strong association between malignant lymphoma and Hashimoto's thyroiditis has frequently been reported. However, it is difficult to detect the lymphomatous transformation of Hashimoto's thyroiditis in the early stage. The purpose of the present study was to examine the usefulness of 67 Ga scintigraphy in the diagnosis and evaluation of the therapeutic effects during follow-up, in patients with a suspected diagnosis of primary thyroid lymphoma. Twenty-five patients who were suspected of having primary thyroid lymphoma and had undergone 67 Ga scintigraphy were studied. 67 Ga planar scintigraphy was performed 72 hours after injection of 67 Ga-citrate. The degree and pattern of 67 Ga accumulation were graded visually. Histopathology on biopsy examination revealed thyroid lymphoma in 17 and Hashimoto's thyroiditis in 8 patients. Abnormal accumulation of 67 Ga in the thyroid was seen in all of the 17 thyroid lymphoma cases with additional mediastinal and abdominal involvement in one. Fifteen of 17 thyroid lymphoma patients also underwent 67 Ga scintigraphy 2-4 weeks after chemotherapy and/or radiotherapy. All 15 patients showed diminishing 67 Ga accumulation and a good clinical course. In one patient with local recurrence, abnormal accumulation could be depicted by follow-up scintigraphy. However, diffuse or enlarged accumulation in the thyroid was seen in all of the 8 Hashimoto's thyroiditis cases. The degree of abnormal accumulation in the thyroid in clinically active phase thyroiditis was more intense than that in the chronic phase thyroiditis. 67 Ga scintigraphy was helpful to confirm the diagnosis of thyroid lymphoma and to evaluate the therapeutic effects during follow-up. However, 67 Ga scintigraphy may not always distinguish thyroid lymphoma from Hashimoto's thyroiditis, especially the active phase of the disease. (author)

  13. The mechanism of 67Ga uptake in animal and human tumours

    International Nuclear Information System (INIS)

    Hammersley, P.A.G.; Cronshaw, S.; Taylor, D.M.; Kernforschungszentrum Karlsruhe G.m.b.H.

    1980-01-01

    The subcellular distribution of 67 Ga has been studied by differential centrifugation in 3 transplantable mouse tumours, 3 transplantable rat tumours, 1 dog tumour, 3 human tumour xenografts and 2 human tumours in situ at various times after injection of the citrate complex. From 24 h post injection the nuclide was located predominantly in lysosomal structures in all the tumours studied. Studies in two murine tumours showed marked differences in the rate of lysosomal accumulation of 67 Ga. In the ADJ/PC6 plasmacytoma lysosomal uptake of 67 Ga had reached a plateau within 15 min while in the S180 tumour lysosomal accumulation of the nuclide occurred over the first 24 h. Normal mouse liver showed a similar pattern to this latter tumour. It is postulated that these variations in the rate of lysosomal accumulation of 67 Ga reflect differences in the permeability of the lysosomal membrane. While large amounts of 67 Ga were found in the crude nuclear fraction of some tumours this was attributed to unbroken cells as studies with purified nuclei from 7 different tumours indicated that between 2 and 14% of the total tumour 67 Ga was associated with the nuclei. (orig.)

  14. Early 67Ga scintigraphy for the localization of abdominal abscesses

    International Nuclear Information System (INIS)

    Hopkins, G.B.; Kan, M.; Mende, C.W.

    1975-01-01

    Sixty patients suspected of having abdominal abscesses were evaluated by early and delayed 67 Ga scintigraphy. The 67 Ga scintigraphs obtained 6 hr after injection correctly localized 18 of 20 abdominal or retroperitoneal abscesses. An additional 13 patients with abnormal scintigraphs had clinically established infections. In no instance was an abscess or inflammatory focus present on delayed scintigraphs that was not evident on the 6-hr study. Two false-positive and two false-negative studies were recorded. Early 67 Ga scintigraphy is warranted in patients with suspected abdominal abscesses

  15. Species of /sup 67/Ga-binding acid mucopolysaccharide in liver

    Energy Technology Data Exchange (ETDEWEB)

    Ando, A.; Ando, I.

    1985-01-01

    It was determined from measuring neutral saccharide in the structure that the principal /sup 67/Ga-binding acid mucopolysaccharide in liver was keratan sulfate and/or keratan polysulfate. On the other hand, it was clarified from the results of mucopolysaccharase treatment that the main /sup 67/Ga-binding acid mucopolysaccharide in liver was neither keratan sulfate, heparan sulfate, heparin, nor chondroitin sulfate A, B and C. Based on the present results, it was deduced that the main /sup 67/Ga-binding acid mucopolysaccharide in liver was keratan polysulfate.

  16. Radiolabelling of DTPA with Ga-67

    International Nuclear Information System (INIS)

    Hamadah, N.; Shaiban, M. R.

    2012-08-01

    Gallium-68 or 67 has been used since the 1970s of the last century. One of the most important uses is the labelling of antibodies using chelating agents, which forms relatively stable complexes to be used in therapeutical and diagnostic applications. Diethylenetriaminepentaacetic acid (DTPA) is a bifunctional chelating agent; has many uses in the preparation of radiopharmaceuticals. We tried in this study the adaptation of DTPA labelling with Ga-67 (which has a longer half-life than Ga-68). This radioisotope gives better time for chemical manipulation. The labelling procedure was carried out under different pH conditions. We found that the best pH is 5 and that the complex is relatively stable for more than 6 hours at room temperature; with a labelling yield >90%. (authors)

  17. The development of automatic chemical processing system for 67Ga production

    International Nuclear Information System (INIS)

    Lee, Dong Hoon; Suh, Yong Sup; Yang, Seung Dae; Chun, Kwon Soo; Hur, Min Goo; Yun, Yong Ki; Kim, Yoon Jong; Hong, Seung Hong

    2003-01-01

    The automatic system for 67 Ga production using for the diagnosis of malignant tumor has been developed. A solvent extraction and an ion exchange chromatography were used for the separation 67 Ga from the irradiated enriched 68 Zn. This system consisted of a solvent separation unit which was composed of micro conductivity cells, air supply tubes, solvent transfer tubes, solenoid valves and glasses, a PLC based controller and a PMU user interface unit for automation. The radiation exposure to the workers and the production time can both be reduced by employing this system during the 67 Ga production phase. After all, the mass production of 67 Ga with high efficiency was possible

  18. Production of *sp67*Ga at the Oslo Cyclotron

    International Nuclear Information System (INIS)

    Bjoernstad, T.; Holtebekk, T.

    1983-01-01

    A method for production of *sp67*Ga at the Oslo Cyclotron is described. The method is based on the nuclear reaction *sp68*Zn (p,2n)*sp67*Ga. The target is natural zinc metal of thickness 1.3 mm fixed by a thin alloy layer to a copper disc for efficient cooling during irradiation. By applying a beam of 29 MeV protons, a maximum production yield of approx. 1.8 mCi/*my*Ah was obtained. By demanding a contamination level of *sp66*Ga <=1%, the ''useful'' yield after a decaytime of 88 h is approx. 0.8 mCi/*my*Ah. Gallium has been separated carrierfree from the zinc matrix by cation exchange from 7.5M hydrocloric acid solutions and prepared as citrate complex at pH 5.5. After sterile filtering, autoclavation, pyrogene testing and analysis for iron and zinc, the *sp67*Ga-radiopharmaceutical has been applied in human investigations at the Ullevaal hospital in Oslo. (Auth.)

  19. /sup 67/Ga-binding substances in abscess and normal tissues

    Energy Technology Data Exchange (ETDEWEB)

    Ando, A; Ando, I; Hiraki, T; Hisada, K; Nitta, K; Ogawa, H

    1984-07-01

    Abscess-induced animals and normal animals were treated with /sup 67/Ga-citrate. Abscess, kidney, heart, lung, and spleen were excised and homogenized. After removal of the nuclear fraction, each of these homogenates was digested with protease. After digestion, the supernatants of the reaction mixtures were applied to a Sephadex G-100 column. Resultant eluates were analyzed for radioactivity, protein, uronic acids, and sialic acids. Sodium sulfate-/sup 35/S was administered to animals that were then treated by the same procedure as that followed for animals treated with /sup 67/Ga-citrate. In abscess, kidney, lung, heart, and spleen, sizeable amounts of /sup 67/Ga had been bound to the sulfated acid mucopolysaccharides with molecular weights of about 10,000, and to the sulfated acid mucopolysaccharides, a species whole molecular weights exceeded 40,000. Based on the results presented here, it is clear that /sup 67/Ga-binding substances in abscess and also in the above four organs are sulfated acid mucopolysaccharides.

  20. The evaluation of 67Ga-scintigraphy in malignant tumor of the urinary tract

    International Nuclear Information System (INIS)

    Arai, Eishoku; Nishibuchi, Shigeo; Katamura, Eiju

    1982-01-01

    67 Ga-scintigraphy was performed in 40 patients with tumor of the urinary tract (18 with renal cell carcinoma, 4 with renal pelvic cancer, 18 with bladder cancer). In patients with renal cell carcinoma, 67 Ga-scintigraphy was positive in 46% of those with primary lesions, and in 80% of those with metastatic lesions. In those with renal pelvic cancer, two with only a primary lesion had a negative 67 Ga-scintigraphy, and one with both primary and metastic lesions and one with only a metastatic lesion after nephrectomy showed distinctly positive 67 Ga-scintigraphy. Among patients with bladder cancer only 31% with primary lesions only had positive 67 Ga-scintigraphy. In conclusion, 67 Ga-scintigraphy is of little use as a diagnostic aid in primary tumors of the urinary tract, but may be useful in the diagnosis of metastatic lesions. (author)

  1. 67 Ga and Zn separation by column chromatography using organic adsorbent

    International Nuclear Information System (INIS)

    Santos, Eliane E. dos; Mestnik, Sonia Ap. C.

    1995-01-01

    The radioisotope 67 Ga is widely used in nuclear medicine for detecting the presence of malignancy and for diagnosis of inflammatory diseases due to its suitable physical characteristics such as half-life of 78 h and γ-rays of 93 KeV(38%), 184(KeV(24%), 296 KeV(22%) and 388 KeV(4%). In this work we present the separation of 67 Ga from Zn using SM-7 (Bio Rad) as absorbent. After setting up the best experimental condition for the absorption of 67 Ga on the chromatographic column the volume of solution to remove all metal contaminants from this column was determined. A characteristic elution curve is also presented. From the studies carried out it was shown that 15,0 ml of 7,0 M HCL were sufficient to remove all contaminants from the column and also that 7,0 ml of 0,01 M HCL were enough to elute all 67 Ga. The 67 Ga separation yield was around 93%. (author). 4 refs., 1 fig

  2. Automated synthesis, characterization and biological evaluation of [{sup 68}Ga]Ga-AMBA, and the synthesis and characterization of {sup nat}Ga-AMBA and [{sup 67}Ga]Ga-AMBA

    Energy Technology Data Exchange (ETDEWEB)

    Cagnolini, Aldo; Chen Jianqing; Ramos, Kimberly; Marie Skedzielewski, Tina; Lantry, Laura E.; Nunn, Adrian D.; Swenson, Rolf E. [Ernst Felder Laboratories, Bracco Research USA Inc., 305 College Road East, Princeton, NJ 08540 (United States); Linder, Karen E., E-mail: karen.e.linder@gmail.co [Ernst Felder Laboratories, Bracco Research USA Inc., 305 College Road East, Princeton, NJ 08540 (United States)

    2010-12-15

    Ga-AMBA (Ga-DO3A-CH{sub 2}CO-G-[4-aminobenzoyl]-QWAVGHLM-NH{sub 2}) is a bombesin-like agonist with high affinity for gastrin releasing peptide receptors (GRP-R). Syntheses for {sup nat}Ga-AMBA, [{sup 67}Ga]Ga-AMBA and [{sup 68}Ga]Ga-AMBA were developed. The preparation of HPLC-purified and Sep-Pak purified [{sup 68}Ga]Ga-AMBA were fully automated, using the built-in radiodetector of the Tracerlab FX F-N synthesizer to monitor fractionated {sup 68}Ge/{sup 68}Ga generator elution and purification. The total synthesis time, including the fractional elution of the generator, was 20 min for Sep-Pak purified material and 40 min for HPLC-purified [{sup 68}Ga]Ga-AMBA. Both [{sup 67}Ga]Ga-AMBA and [{sup 177}Lu]Lu-AMBA showed comparable high affinity for GRP-R in the human prostate cancer cell line PC-3 in vitro (k{sub D}=0.46{+-}0.07; 0.44{+-}0.08 nM), high internalization (78; 77%) and low efflux from cells at 2 h (2.4{+-}0.7; 2.9{+-}1.8%). Biodistribution results in PC-3 tumor-bearing male nude mice showed comparable uptake for [{sup 177}Lu]Lu-, [{sup 111}In]In-, [{sup 67}Ga]Ga- and [{sup 68}Ga]Ga-AMBA.

  3. Clinical applications of Ga-67 DFO-DAS-fibrinogen

    International Nuclear Information System (INIS)

    Iio, Masahiro; Ohtake, Tohru; Nishikawa, Junichi; Watanabe, Toshiaki; Yasuhara, Hiroshi; Ohashi, Shigenobu; Takayama, Yutaka; Tada, Yusuke; Shirakawa, Motoaki

    1987-01-01

    Ga-67 DFO-DAS-fibrinogen scanning was performed in 15 patients to detect fresh arterial thrombus. Seven patients were preoperative cases of aortic aneurysm and eight were postoperative cases of graft bypass. Scanning was performed on the first and second days after the injection. Nine of 13 grafts in eight cases were visualized by 67 Ga-DFO-DAS-fibrinogen scan. Velour Dacron grafts were more strongly visualized compared with woven Dacron or Goatex. In three patients with aortic aneurysm in whom fresh thrombus was identified by operative findings, arterial thrombus was clearly visualized by 67 Ga-DFO-DAS-fibrinogen scan, whereas in three other patients with aortic aneurysm, thrombus was not visualized, although it was identified by other examinations. In one case, a marked accumulation was observed in the abdominal aorta, although no arterial thrombus was found at operation. This was thought to be an accumulation in a blood pool because it decreased on the second day. We think it important to observe the relative changes of accumulation. (author)

  4. Clinical evaluation of 67Ga-citrate uptake in the hilar areas

    International Nuclear Information System (INIS)

    Kubota, Hisashi; Komatani, Akio; Watarai, Jiro; Yamaguchi, Koichi; Takamiya, Makoto.

    1983-01-01

    In the last 4 years 67 Ga-citrate scans had been performed at our department in 914 patients with various diseases. Out of these, 173 showed 67 Ga uptake of varied degree and patterns in the hilar areas. The clinical records of the 173 patients were reviewed to clarify the significance of the hilar uptake. The results were as follows : 1. On a routine 67 Ga-citrte scintigraphy, physiological hilar uptake may be seen in any disease. 2. Bilateral symmetrical hilar 67 Ga accumulation revealed no pathological significance in most cases. Such a 67 Ga uptake might be said as physiological even in the patients with malignancy, if any pathological findings in the both hila could not be noted on the chest film. Degree of the hilar uptake does not contribute much in differentiation between physiological uptake and abnormal one. 3. Primary lung cancer or metastatic lymph node from any origin at the hilar region demonstrated large and definite accumulation. Even if bilateral hilar uptake was noted in these cases, smaller and lower accumulation of the unaffected side might be diagnosed as physiological. (author)

  5. Distribution of heparin-/sup 67/Ga in tumor-bearing rats

    Energy Technology Data Exchange (ETDEWEB)

    Hiraki, T; Ando, A; Sanada, S [Kanazawa Univ. (Japan). School of Paramedicine; Ando, I; Hisada, K

    1976-06-01

    Heparin is a kind of acidic mucopolysaccharide. The distribution of heparin-/sup 67/Ga complex in tumor-bearing rats was investigated by administering it to rats into which Yoshida sarcoma had been transplanted subcutaneously. These rats were sacrificed at 10 minutes, 30 minutes, 1 hour and 3 hours after injection. Radioactivity of the tumor, blood, muscle, liver, kidney, spleen and urine were measured with a well-type scintillation counter. Retention values in these organs and excretion rates in the urine were calculated. Excretion rates (%/dose) of heparin-/sup 67/Ga in 10 min., 30 min., 1 hour, and 3 hours were 38.2%, 67.5%, 79.5% and 78.0%, respectively. From these facts, it was thought that heparin-/sup 67/Ga complex was not suitable for tumor scanning, but that this compound might be a suitable agent for the renal function test.

  6. sup 67 Ga citrate imaging in AIDS-related pneumocystis carinii pneumonia in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Kosuda, Shigeru; Shioyama, Yasukazu; Kutsukake, Yasumichi; Tanaka, Junji; Asumi, Masahiko; Ito, Kiyonobu; Kamata, Noriko; Suzuki, Kenzo (Tokyo Metropolitan Komagome Hospital, Tokyo (Japan))

    1991-01-01

    Six AIDS patients with Pneumocystis carinii pneumonia (PCP) underwent {sup 67}Ga scan as part of their evaluation. Only one patient of them showed the characteristic {sup 67}Ga distribution pattern for PCP, that is, diffuse, increased, bilateral lung activity greater than liver activity. Two patients who were receiving therapy for PCP and one patient with recurrent PCP showed focal or uneven {sup 67}Ga lung uptake. In the four patients, the scan showed more extensive lesion than the chest radiograph. The other two patients who died 2 months later of cellular immunodeficiency showed no or very slight lung uptake of {sup 67}Ga. In summary, {sup 67}Ga scanning is useful diagnostic procedure in evaluation of PCP in patients with AIDS. (author).

  7. The effect of the administration of iron on Ga-67 uptake in animal tumor and biodistribution

    International Nuclear Information System (INIS)

    Furukawa, Keiji

    1983-01-01

    In 1979 Larson reported that the uptake of Ga-67 in tumor cell was preceded by binding of the Ga-67 to transferrin. Since that time there have been many papers concerning changes in Ga-67 accumulation in experimental tumor by administration of iron before and after Ga-67 injection. This study was undertaken in the attempt to discern what changes are produced in Ga-67 images of tumor-bearing rabbits (VX-II) when iron was administered before and after Ga-67 injection. Additionally, the relationships between the change in the serum iron concentration in the tumor tissue in mice bearing Ehrlich's ascites tumor were studied. The following results were obtained. 1) The tumor uptake and biodistribution of Ga-67 following administration of iron in the form of Fesin (saccharated ferric oxide) or ferric-citrate is obviously diminished. This iron administration leads to an elevated excretion of Ga-67 from tumor and other organs except from bone. From this results, it was found that Ga-67 binds somewhat less avidity than iron to various iron transport protein. Accordingly, Ga-67 biodistribution may be markedly influenced by iron-loading. 2) The Ga-67 activity in blood following administration of iron was noted to suddenly markedly decrease. However, 24-48 hours after iron injection the Ga-67 activity in blood gradually increased. This result suggests that the Ga-67 displaced into the extravascular space by iron-loading reentered the vascular space when the iron concentration of serum returned to normal. 3) The accumulation of Ga-67 in the tumor and soft tissues was slightly decreased compared with controls after iron administration. However, the tumor to blood ratio (T/B) of Ga-67 in mice by iron loading was several time greater than that of Ga-67 alone because the clearance of Ga-67 from the blood was more accelated than that of tumor. The large tumor to blood ratio (T/B) would be advantageous in obtaining a more distinct tumor scan. (author)

  8. Hybrid SPECT/CT: Principle, dosimetry and quality control; Imagerie hybride: principe, dosimetrie et controle de qualite

    Energy Technology Data Exchange (ETDEWEB)

    Hapdey, S.; Gardin, I.; Salles, A.; Rousseliere, F.; Edet-Sanson, A.; Vera, P

    2009-05-15

    The recent introduction of hybrid systems combining a SPECT and a CT in nuclear medicine, greatly improved the diagnostic accuracy for particular clinical indications, due to the possible attenuation and/or scatter correction of the SPECT functional images and the availability of helpful anatomic information. Although the gamma cameras performances are noticeably comparable, the associated CT furnished by the manufacturer are relatively different from each other. Whatever the system is, the introduction of CT in the nuclear diagnostic process results in a significant increase of the patient dose. This dose increase should be justified and optimized considering both the clinical question and the CT settings available on these systems. The installation of a hybrid system must be accompanied by the management of a documentary quality insurance program, jointly developed by the technologists, physicists and physicians, both covering its clinical use and the associated dosimetry issues as monitoring its performances. Particular quality control procedures have to be defined because of the coupling between the two devices. (authors)

  9. The role of hybrid SPECT-CT in oncology: current and emerging clinical applications

    International Nuclear Information System (INIS)

    Chowdhury, F.U.; Scarsbrook, A.F.

    2008-01-01

    Single photon emission computed tomography - computed tomography (SPECT-CT) is an emerging dual-modality imaging technique with many established and potential clinical applications in the field of oncology. To date, there has been a considerable emphasis on the benefits of integrated positron emission tomography - computed tomography (PET-CT) in oncology, but relatively little focus on the clinical utility of SPECT-CT. As with PET-CT, accurate co-registration of anatomical and functional data from a combined SPECT-CT camera often provides complementary diagnostic information. Both sensitivity (superior disease localization) and specificity (exclusion of false-positives due to physiological tracer uptake) are improved, and the functional significance of indeterminate lesions detected on cross-sectional imaging can be defined. This article will review the scope of hybrid SPECT-CT in oncology and illustrate both current and emerging clinical applications

  10. Relationship between Ga-67 uptake and radiotherapeutic response of primary lung cancer (squamous cell carcinoma)

    International Nuclear Information System (INIS)

    Higashi, Kotaro; Takase, Shuko; Ohguchi, Manabu; Seki, Hiroyasu; Okimura, Tetsuro; Miyamura, Toshio; Yamamoto, Itaru; Rikimaru, Shigeho.

    1992-01-01

    This investigation was undertaken to evaluate the relationship between Ga-67 uptake and radiotherapeutic response of primary lung cancer (squamous cell carcinoma), Ga-67 uptake of tumor was estimated on 16 patients with untreated primary lung cancer (squamous cell carcinoma). Ga-67 uptake was then compared with the response to radiation therapy (tumor reduction ratio). There was statistically significant inverse correlation between Ga-67 uptake and response to radiation therapy (r=-0.701, p<0.01). The fewer the Ga-67 accumulation in the tumor, the more effective radiotherapy in reducing tumor size. In conclusion, Ga-67 scintigraphy appears to be able to predict the response of primary lung cancer (squamous cell carcinoma) to radiation therapy. (author)

  11. Gallium-67-labeled lactam bridge-cyclized alpha-melanocyte stimulating hormone peptide for primary and metastatic melanoma imaging.

    Science.gov (United States)

    Guo, Haixun; Yang, Jianquan; Shenoy, Nalini; Miao, Yubin

    2009-12-01

    The purpose of this study was to examine the melanoma imaging properties of a novel 67Ga-labeled lactam bridge-cyclized alpha-melanocyte stimulating hormone (alpha-MSH) peptide. A lactam bridge-cyclized alpha-MSH peptide, DOTA-GlyGlu-CycMSH {DOTA-Gly-Glu-c[Lys-Nle-Glu-His-DPhe-Arg-Trp-Gly-Arg-Pro-Val-Asp]}, was synthesized and radiolabeled with 67Ga. The melanoma targeting and pharmacokinetic properties of 67Ga-DOTA-GlyGlu-CycMSH were determined in B16/F1 flank primary melanoma-bearing and B16/F10 pulmonary metastatic melanoma-bearing C57 mice. Flank primary melanoma and pulmonary metastatic melanoma imaging were performed by small animal single photon emission computed tomography (SPECT)/CT using 67Ga-DOTA-GlyGlu-CycMSH as an imaging probe. 67Ga-DOTA-GlyGlu-CycMSH was readily prepared with greater than 95% radiolabeling yield. 67Ga-DOTA-GlyGlu-CycMSH exhibited substantial tumor uptake (12.93 +/- 1.63%ID/g at 2 h postinjection) and prolonged tumor retention (5.02 +/- 1.35%ID/g at 24 h postinjection) in B16/F1 melanoma-bearing C57 mice. The uptake values for nontarget organs were generally low (<0.30%ID/g) except for the kidneys at 2, 4, and 24 h postinjection. 67Ga-DOTA-GlyGlu-CycMSH exhibited significantly (p < 0.05) higher uptakes (1.44 +/- 0.75%ID/g at 2 h postinjection and 1.49 +/- 0.69%ID/g at 4 h postinjection) in metastatic melanoma-bearing lung than those in normal lung (0.15 +/- 0.10%ID/g and 0.17 +/- 0.11%ID/g at 2 and 4 h postinjection, respectively). Both flank primary B16/F1 melanoma and B16/F10 pulmonary melanoma metastases were clearly visualized by SPECT/CT using 67Ga-DOTA-GlyGlu-CycMSH as an imaging probe 2 h postinjection. 67Ga-DOTA-GlyGlu-CycMSH exhibited favorable melanoma targeting and imaging properties, highlighting its potential as an effective imaging probe for early detection of primary and metastatic melanoma.

  12. Albumin microspheres labeled with Ga-67 by chelation: concise communication

    International Nuclear Information System (INIS)

    Hnatowich, D.J.; Schlegel, P.

    1981-01-01

    Albumin microspheres have been synthesized with EDTA and DTPA chelating groups covalently bound to their surface. The microspheres may be labeled with Ga-67 at high yield (97 +- 2%) by transcomplexation from a 0.1 M Ga-67 acetate solution. With EDTA microspheres the resulting label dissociates only slightly after 24 hr in 50% plasma at 37 0 C, whereas with DTPA microspheres the label shows no detectable dissociation over this period. By contrast, microspheres without chelating groups lose their label virtually completely under these conditions. Following intravenous administration of sized Ga-67 DTPA microspheres in mice, about (84 +- 16)% of the activity localizes in the lungs at 5 min, with (60 +- 7)% remaining after 2 h. Since labeling is by chelation, the microspheres may also be tagged with other metallic radionuclides

  13. Early detection of interstitial pneumonia by 67Ga-citrate scintigraphy

    International Nuclear Information System (INIS)

    Ito, Shinsaku; Mikami, Riichiro; Ryujin, Yoshitada

    1985-01-01

    In this paper we report our recent experience indicating usefulness of 67 Ga-citrate scintigraphy in 4 cases with inflammatory pulmonary diseases. These cases showed abnormal pulmonary 67 Ga uptake with normal chest radiographs. The first case with malignant lymphoma and the second one with lung cancer suffered from pulmonary infection following secondary immuno-insufficiency due to radiotherapy and chemotherapy. Pneumocystis carinii was suspected as causative agent in the first case, and gram negative bacilli in the second case. The third case with lung cancer developed radiation pneumonia after radiotherapy. The fourth case with acute bronchitis developed drug induced interstitial pneumonia presumably due to minocycline administration. It is concluded that 67 Ga-citrate scintigraphy is more sensitive for early detection of interstitial pneumonia than routine chest radiography. (author)

  14. Ga-67 tumor scan in malignant diffuse mesothelioma. Comparison with CT and pathological findings

    International Nuclear Information System (INIS)

    Yoshida, Shoji; Fukumoto, Mitsutaka; Motohara, Tomofumi; Oobayashi, Kayoko; Takada, Yoshiki; Tsubota, Noriaki; Sashikata, Terumasa

    1999-01-01

    Malignant diffuse mesothelioma is characterized by more difficult diagnosis and worse prognosis than other pleural tumors. In the Department of Thoracic Surgery, Hyogo Medical Center for Adults, 11 patients underwent panpleuropneumonectomy for this disease between January, 1988 and March, 1993. In 7 of these cases, Ga-67 scans were obtained before the operation. To clarify the factors affecting Ga-67 uptake in the pleural tumor, we compared Ga-67 uptake on the involved side of the thorax with CT and the pathological findings of the tumor. Regarding the use of Ga-67 scan imaging for the diagnosis of this disease, a number of related findings must be considered, such as an encircled wide Ga-67 uptake in the thickened pleural involvement and a diffuse slight Ga-67 uptake on the affected side with very slight involvement of the pleura. When the involved pleural thickness was over 6 mm, a definite correlation was found between the degree of Ga-67 uptake and the macroscopic thickness of mesothelioma in resected specimens. Thickness of the pleura on CT images demonstrates the real tumor thickness in the case of thickened involvement but in the case of thin involvement the real thickness of active mesothelioma could not be identified. No definite correlation was found between the degree of Ga-67 uptake and the histological type, or among microscopic findings, such as the extent of tumor parenchyma, interstitial volume and tumor vascularity. Our results suggest that the Ga-67 scan is very useful for revealing the extent of pleural involvement, especially when this involvement is more than 6 mm thick. (author)

  15. Ga-67 tumor scan in malignant diffuse mesothelioma. Comparison with CT and pathological findings

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Shoji; Fukumoto, Mitsutaka [Kochi Medical School, Nankoku (Japan); Motohara, Tomofumi; Oobayashi, Kayoko; Takada, Yoshiki; Tsubota, Noriaki; Sashikata, Terumasa

    1999-02-01

    Malignant diffuse mesothelioma is characterized by more difficult diagnosis and worse prognosis than other pleural tumors. In the Department of Thoracic Surgery, Hyogo Medical Center for Adults, 11 patients underwent panpleuropneumonectomy for this disease between January, 1988 and March, 1993. In 7 of these cases, Ga-67 scans were obtained before the operation. To clarify the factors affecting Ga-67 uptake in the pleural tumor, we compared Ga-67 uptake on the involved side of the thorax with CT and the pathological findings of the tumor. Regarding the use of Ga-67 scan imaging for the diagnosis of this disease, a number of related findings must be considered, such as an encircled wide Ga-67 uptake in the thickened pleural involvement and a diffuse slight Ga-67 uptake on the affected side with very slight involvement of the pleura. When the involved pleural thickness was over 6 mm, a definite correlation was found between the degree of Ga-67 uptake and the macroscopic thickness of mesothelioma in resected specimens. Thickness of the pleura on CT images demonstrates the real tumor thickness in the case of thickened involvement but in the case of thin involvement the real thickness of active mesothelioma could not be identified. No definite correlation was found between the degree of Ga-67 uptake and the histological type, or among microscopic findings, such as the extent of tumor parenchyma, interstitial volume and tumor vascularity. Our results suggest that the Ga-67 scan is very useful for revealing the extent of pleural involvement, especially when this involvement is more than 6 mm thick. (author)

  16. /sup 67/Ga-binding substances in stomach, small intestine, pancreas, and muscle

    Energy Technology Data Exchange (ETDEWEB)

    Ando, Atsushi; Ando, Itsuko; Hirake, Tatsunosuke; Hisada, Kinichi

    1985-11-01

    Normal male rats were injected with either gallium citrate /sup 67/Ga or sodium sulfate /sup 35/S. After 24 h, the stomach, small intestine, pancreas, and muscle were excised and homogenized. After the removal of the nuclear fraction, each of these homogenates was digested with protease. After digestion, the supernatants of the reaction mixtures were applied to a Sephadex-G-100 column. The radioactivity was eluted with buffer solution. The resultant eluates were analyzed for radioactivity and the levels of proteins, uronic acids, and sialic acids. In all four organs, sizable amounts of /sup 67/Ga were bound to sulfated acid mucopolysaccharides with molecular masses of about 10,000 daltons and to sulfated acid mucopolysaccharides, a species whose molecular masses exceed 40,000 daltons. In the stomach, large amounts of /sup 67/Ga were bound to sulfated acid mucopolysaccharides with molecular masses of about 10,000 daltons. From these results, it is obvious that the main /sup 67/Ga-binding substances in these four organs are sulfated acid mucopolysaccharides, and that these acid mucopolysaccharides play the most important role in the concentration of /sup 67/Ga in these organs.

  17. Relationship between binding activity of sup 67 Ga and low sulfated acid glycosaminoglycans

    Energy Technology Data Exchange (ETDEWEB)

    Ohkubo, Yasuhito; Tsukada, Fumitake; Kohno, Hiroyuki (Tohoku Coll. of Pharmacy, Sendai (Japan)); Kubodera, Akiko (Science Univ. of Tokyo (Japan). School of Pharmaceutical Sciences)

    1989-01-01

    Sulfate content of acid glycosaminoglycan (AGAG) extracted from granuloma which had been produced by turpentine oil was inversely proportional to the amount of {sub 67}Ga accumulation in the granuloma. Additionally, the lowest sulfation occurred in granuloma at a peak of inflammation when the uptake of {sub 67}Ga had reached a maximum. On the basis of electrophoretic pattern, sulfate content, and specific optical rotation, it was concluded that acid glycosaminoglycans obtained from granuloma are mainly composed of chondroitin sulfate-A, -B, and desulfated heparin, while haparan sulfate was a minor component. From in vitro assays, desulfated acid glycosaminoglycans, especially desulfated-heparin and desulfated-heparan sulfate, were found to have a high affinity to {sub 67}Ga. These results suggest that low- or de-sulfation of AGAG is related to the accumulation of {sub 67}Ga in inflammatory lesions such as granuloma. Moreover, these results suggest that {sub 67}Ga does not bind to glycosaminoglycans via sulfuric acid residues. (author).

  18. Determination of the lysosomal role in tumor accumulation of 67Ga by dual-tracer studies

    International Nuclear Information System (INIS)

    Ando, Atsushi; Ando, Itsuko; Hiraki, Tatsunosuke; Yamada, Norihisa; Hisada, Kinichi

    1989-01-01

    The lysosomal role in tumor accumulation of 67 Ga was determined by dual-tracer( 67 Ga and 46 Sc) studies. It became clear that 67 Ga essentially did not accumulate in the tumor lysosome, and that the lysosome did not play a major role in tumor accumulation of 67 Ga. In addition, it was revealed that tumor lysosome was hardly disrupted at all in some phases of fractionation procedures. (author)

  19. Evaluation of Ga-67 scintigraphy for salivary gland tumors

    International Nuclear Information System (INIS)

    Takase, Hiroshi; Toyama, Michio; Eguchi, Tooru; Maeda, Kadzuo

    1993-01-01

    It is often difficult to exactly grasp the malignancy of salivary gland tumor because of inadaptability of percutaneous biopsy. The purpose of this study is to discuss whether Ga-67 scintigraphy on patient with salivary gland tumor can provide useful information for differential diagnosis. We studied retrospectivelly the case records of twenty patients with parotid or submandibular gland tumors admitted to the Nippon Dental University, School of Dentistry at Niigata, between January 1984 and December 1991. The final diagnoses of these twenty patients were pleomorphic adenoma in 11, adenocarcinoma in 3, adenoid cystic carcinoma in 3, Warthin's tumor in 1, oncocytoma in 1, and carcinoma in pleomorphic adenoma in 1. The scintigraphic patterns of the twenty patients were classified as negative (-), weakly positive (+), moderate positive (++), strongly positive (+++). Malignant tumors showed increased activity in Ga-67 images except those in three patients with adenoid cystic carcinomas. We concluded that Ga-67 scintigraphy may be useful to distinguish benign salivary gland tumors from adenocarcinoma or carcinoma in pleomorphic adenoma, but not be useful in detection of adenoid cystic carcinoma. (author)

  20. Thrombus scintigraphy with Ga-67 DFO-DAS-Fibrinogen, 2

    International Nuclear Information System (INIS)

    Kawasaki, Yukiko

    1987-01-01

    In our previous in vivo study 67 Ga DFO-DAS-Fibrinogen was assessed for its usefulness as a radiopharmaceutical for the detection of thrombin in experimental animals (Report 1). The present study was undertaken to appraise the diagnostic value of 67 Ga DFO-DAS-Fibrinogen in human disease, especially in relation to blood coagulability as well as to thrombolytic drug regimen being given, in an effort to investigate its clinical applicability. Involved in this study were 48 patients with thrombosis proven by X-ray CT and other examinations. Of these 48, 42 had arterial thrombosis (20 with aortic aneurysm including the dissecting form, 11 in postoperative condition following vascular surgery with a prosthesis, 9 with intracardiac thrombosis accompanying heart disease, and 1 each with occlusive arteriosclerosis and cerebral infarction) and 6 had venous thrombosis. The 67 Ga DFO-DAS-Fibrinogen test proved to be positive in 55 % of arterial thrombin and in 50 % of venous thrombin. It is interesting to note that as high a positivity rate as 80 % was obtained for aortic aneurysm, although the positivity rate was disappointingly low for left atrial thrombin. No distinct correlation was noted to exist between the degree of accumulation of the tracer in thrombotic lesions and any of factors conceivably of clinical releavance, i.e. time elapsing from onset till testing, thrombolytic medication being given, and hematological factors. 67 Ga DFO-DAS-Fibrinogen appeared to be a radiodiagnostic agent that could possibly indicate the existing activity status of thrombosis. (author)

  1. Diffuse abdominal uptake of Ga-67 citrate in a patient with hypoproteinemia

    International Nuclear Information System (INIS)

    Kim, E.E.; Gobuty, A.; Gutierrez, C.

    1983-01-01

    A 3-wk-old male, with abdominal distention and severe hypoproteinemia from poor nutrition, underwent a study that showed a persistent diffuse abdominal uptake of Ga-67 citrate, indicating pyogenic or tuberculous peritonitis. However, there were no corresponding clinical or laboratory findings. After a 1-wk course of hyperalimentation with albumin, furosemide, and protein, repeat radiographs showed reduction in bowel gas. It is suggested that hypoproteinemia should be considered as a possibility in the differential diagnosis when there is diffuse abdominal uptake of Ga-67 citrate, with careful clinical correlation. Possible mechanism of Ga-67 uptake in the peritoneal cavity is suggested

  2. Use of 67Ga citrate in the diagnosis of lung cancer

    International Nuclear Information System (INIS)

    Bogdasarov, Yu.B.; Zajtseva, T.I.; Gabuniya, R.I.; Abramov, V.F.

    1981-01-01

    A study was of the potentialities of 67 Ga citrate in the diagnosis of lung cancer, in differentiation from benign tumors and chronic inflammatory processes of the lungs. A total of 101 lung cancer patients were examined, of them 64 with central, and 37 with peripheral cancer. The results of radionuclide studies were correlated with those of surgery and with morphological findings. It has been established that in central cancer scintigraphy with 67 Ga citrate gives positive results in 87% of cases, and in peripheral cancer in 89%. This method is of great value for the diagnosis of cancer metastases to the mediastinal lymph nodes. No correlation between the intensity of 67 Ga citrate accumulation in lung tumors and their histological structure has been revealed [ru

  3. Labeling of antibodies with a 67Ga-phenolic aminocarboxylic acid chelate. Pt. 1

    International Nuclear Information System (INIS)

    Schuhmacher, J.; Matys, R.; Hauser, H.; Maier-Borst, W.; Matzku, S.

    1986-01-01

    As a chelating agent for labeling antibodies (Abs) with metallic radionuclides, a propionic acid substituted ethylenediamine N, N'-di-[(o-hydroxyphenyl) acetic acid] (P-EDDHA), which tighly complexes 67 Ga, was synthetized. The 67 Ga-P-EDDHA chelate was coupled in aqueous solution to IgG at a molar ratio of 1:1 via carbodiimide. The average coupling yield was 15%. A specific activity of 4 mCi/mg IgG could be obtained with commercially supplied 67 Ga. In vitro stability was evaluated in human serum at 37 0 C and showed a half-life of about 120 h for the release of 67 Ga from the labeled Ab during the initial phase of incubation. This in vitro halflife is similar to that measured for 111 In-DTPA labeled Abs. Because of the high stability of the 67 Ga-P-EDDHA chelate, the in vivo formation of radioactive lebeled transferrin by transchelation, as described for 111 In-DTPA labeled Abs, should, however, be reduced by this labeling technique. (orig.)

  4. /sup 67/GA accumulation in inflammatory lesion and its mechanism: Comparison with malignant tumor

    Energy Technology Data Exchange (ETDEWEB)

    Ando, Atsushi; Ando, Itsuko; Hiraki, Tatsunosuke; Nitta, Kazuo; Ogawa, Hiroshi; Katsuda, Shogo; Tonami, Norihisa; Hisada, Kinichi

    1987-03-01

    The accumulation of /sup 67/Ga in inflammatory lesions increased with time after injection of turpentine oil and reached a plateau 5 days later. At that time the uptake in the lesions was larger than any other tissue, after ten days the lesion uptake decreased. In experiments using rats which has been kept for 5 days after subcutaneous injection of turpentine oil, the accumulation of /sup 67/Ga in inflammatory lesions increased with time until six days after administration of /sup 67/Ga-citrate. It is clear from this study that /sup 67/Ga is avidly accumulated in areas where the subcutaneous tissue is infiltrated with neutrophils and macrophages, that it is not accumulated at the sites in which neutrophils are crowded, that nuclear materials, mitochondria, lysosomes and microsomes do not play a major role in /sup 67/Ga accumulation in the lesion and that the main binding acid in the lesion is a mucopolysaccharide which is none of the following: keratan sulfate, heparan sulfate, heparin, or chondroitin sulfate A, B or C. It is presumed that the main /sup 67/Ga binding acid mucopolysaccharide is keratan polysulfate (or other oversulfate acid mucopolysaccharides).

  5. Sensitivity analysis of the titan hybrid deterministic transport code for SPECT simulation

    International Nuclear Information System (INIS)

    Royston, Katherine K.; Haghighat, Alireza

    2011-01-01

    Single photon emission computed tomography (SPECT) has been traditionally simulated using Monte Carlo methods. The TITAN code is a hybrid deterministic transport code that has recently been applied to the simulation of a SPECT myocardial perfusion study. For modeling SPECT, the TITAN code uses a discrete ordinates method in the phantom region and a combined simplified ray-tracing algorithm with a fictitious angular quadrature technique to simulate the collimator and generate projection images. In this paper, we compare the results of an experiment with a physical phantom with predictions from the MCNP5 and TITAN codes. While the results of the two codes are in good agreement, they differ from the experimental data by ∼ 21%. In order to understand these large differences, we conduct a sensitivity study by examining the effect of different parameters including heart size, collimator position, collimator simulation parameter, and number of energy groups. (author)

  6. Prognostic value of GA-67 scintigraphy in pre-therapy patients of hodgkin's disease

    International Nuclear Information System (INIS)

    Muhammad Numair Younis; Hamid Naseer; Mohammad Salim; Saeeda Asghar

    2004-01-01

    Ga-67 scintigraphy (GS) has an established role in the diagnosis and management of Hodgkin's disease (HD). Recently published data suggests that uptake of Ga-67 estimated on GS in pre-therapy patients can differentiate between two most common varieties of HD namely Mixed Cellularity (MC) and Nodular Sclerosing (NS). We tried to evaluate the importance of Ga-67 uptake in pre-therapy patients of HD in relationship with the disease outcome and patient survival. GS was performed in 70 pre-therapy patients of HD. The GS was positive in 64 of 70 patients with 135 lesions showing Ga-67 uptake. The uptake ratios were calculated using semi-quantitative technique. The ratios were compared for different sub-type of HD. The initial uptake ratios were compared with the results of therapy and patient survival one year after completing the therapy. The results show that Ga-67 uptake ratios were higher in patients with MC sub-type than in other sub-types of HD. Also the patients showing higher Ga-67 avidity on pre-therapy scans showed better survival and early response to chemotherapy. The initial stage of disease at the time of diagnosis also has a direct relationship with the disease outcome. We conclude that GS in pre-therapy patients of HD can provide valuable information and can be used as reliable indicator of prognosis in conjunction with the stage of disease at the time of diagnosis. (authors)

  7. Receptor-mediated targeting of 67Ga-Deferoxamine-Folate to folate-receptor-positive human kb tumor xenografts

    International Nuclear Information System (INIS)

    Mathias, Carla J.; Wang, Susan; Low, Philip S.; Waters, David J.; Green, Mark A.

    1999-01-01

    The radiochemical synthesis and stability of 67 Ga-deferoxamine-folate ([ 67 Ga]Ga-DF-Folate) were examined as a function of DF-Folate concentration. Optimal labeling occurred at DF-Folate concentrations ≥2.5 μg/mL. To define the possible biological significance of variations in product formulation, the biodistribution of [ 67 Ga]Ga-DF-Folate was examined as a function of administered deferoxamine-folate dose in an athymic mouse KB tumor model. The folate-receptor-positive KB tumors were found to concentrate the 67 Ga radiolabel in a dose-dependent fashion, consistent with saturable involvement of the folate receptor in mediating tumor accumulation of the radiopharmaceutical

  8. Myositis ossificans with Ga-67 citrate positivity

    International Nuclear Information System (INIS)

    Moreno, A.J.; Yedinak, M.A.; Spicer, M.J.; Turnbull, G.L.; Byrd, B.F.; Brown, T.J.

    1985-01-01

    A 16 year-old boy presented with a firm mass within the left thigh. Ga-67 citrate and bone scintigraphy revealed soft tissue radiotracer accumulation within the mass lesion. Radiographs and xerography of the left thigh revealed calcification within the soft tissue mass typical of myositis ossificans. The patient's clinical course was uneventful

  9. Labeling of monoclonal antibodies with a 67Ga-phenolic aminocarboxylic acid chelate. Part II. Comparison of immunoreactivity and biodistribution of monoclonal antibodies labeled with the 67Ga-chelate or with 131I.

    Science.gov (United States)

    Matzku, S; Schuhmacher, J; Kirchgessner, H; Brüggen, J

    1986-01-01

    Coupling of the 67Ga-P-EDDHA chelate via carbodiimide to the anti-melanoma monoclonal antibody (Mab) M.2.9.4 resulted in a low degree of oligomerization, but a considerable degree of intra-molecular (inter-chain) cross-linking. However, this did not impair immunoreactivity, nor did the half-life in vivo differ substantially from that of 131I-M.2.9.4. Biodistribution analysis in normal mice showed Ga:I ratios near 1 in the blood and other tissues not involved in degradation and label excretion. In tissues of the reticulo-endothelial system (RES) and the kidneys, Ga:I ratios up to 2.51 were reached within 4 days of administration. In antigen-positive MeWo tumor tissue, retention of 67Ga also excreted that of 131I, so that tumor; organ ratios (except tumor:liver) were superior for the 67Ga-labeled MAb. It is concluded that the method of coupling pre-established 67Ga-P-EDDHA chelate to antibody results in a functionally intact tracer molecule, whose persistence in vivo is not significantly impaired. The major difference to I-labeled MAbs may be a prolonged retention of Ga in tissues (cells) physiologically involved in antibody catabolism.

  10. Preparation of carrier-free 67Ga, by irradiation of natural zinc with protons

    International Nuclear Information System (INIS)

    Fernandes, L.; Silva, C.P.G. da; Barbosa, M.F. de.

    1983-02-01

    A method for the preparation of carrier-free 67 Ga is described. Natural zinc plates were irradiated with protons. After a decay period of four days, the irradiated targets were dissolved in concentrated hydrochloric acid and the solution percolated through a glass column containing a cationic resin. 67 Ga was eluted with 3,5 N HCl; the eluted solution was evaporated to dryness, taken up in 3,8% sodium citrate solution and sterilized. Sterility tests were carried out according to the requirements of the U.S. Pharmacopeia. Chemical purity of 67 Ga citrate was determined by spot tests and by atomic absorption spectrophotometry. The radioactive purity was verified by gamma spectrometry. The product was endovenously injected into Wistar rats with experimental abcesses, and in a patient with adrenal neuroblastoma. The results shown a high accumulation of 67 Ga in soft tissue tumors. (Author) [pt

  11. Comparative study on lysosomal accumulation of 67Ga and 111In in Morris hepatoma 7316A

    International Nuclear Information System (INIS)

    Takeda, S.; Uchida, T.; Matsuzawa, T.

    1977-01-01

    Intracellular localization of 67 Ga and 111 In was investigated in Morris hepatoma 7316A and in normal Buffalo rat liver cells by a cell fractionation method at 48 hr after an intraperitoneal injection of the nuclides. Lysosomal fractions of the tumor and normal liver cells had the highest relative specific radioactivities of the nuclides (p 67 Ga (p 67 Ga seemed to indicate that 67 Ga determines lysosomal functions of tumor cells more precisely than 111 In

  12. Comparison of diagnostic accuracy of {sup 111}In-pentetreotide SPECT and {sup 68}Ga-DOTATOC PET/CT: A lesion-by-lesion analysis in patients with metastatic neuroendocrine tumours

    Energy Technology Data Exchange (ETDEWEB)

    Binnebeek, S. van; Vanbilloen, B.; Baete, K.; Terwinghe, C.; Koole, M.; Mortelmans, L. [KU Leuven, Nuclear Medicine, University Hospitals Leuven and Department of Imaging and Pathology, Leuven (Belgium); Mottaghy, F.M. [Maastricht University Medical Center, Department of Nuclear Medicine, Maastricht (Netherlands); University Hospital Aachen, Department of Nuclear Medicine, Aachen (Germany); Clement, P.M. [KU Leuven, Medical Oncology, University Hospitals Leuven and Laboratory of Experimental Oncology, Leuven (Belgium); Bogaerts, K. [KU Leuven and UHasselt, Department of Public Health and Primary Care (I-BioStat), Leuven (Belgium); Haustermans, K. [KU Leuven, Radiation Oncology, University Hospitals Leuven and Department of Oncology, Leuven (Belgium); Nackaerts, K. [University Hospitals Leuven, Pulmonology, Leuven (Belgium); Cutsem, E. van; Verslype, C. [KU Leuven, Division of Digestive Oncology, University Hospitals Leuven and Department of Oncology, Leuven (Belgium); Verbruggen, A. [KU Leuven, Laboratory for Radiopharmacy, Leuven (Belgium); Deroose, C.M. [KU Leuven, Nuclear Medicine, University Hospitals Leuven and Department of Imaging and Pathology, Leuven (Belgium); University Hospitals Leuven, Nuclear Medicine, Leuven (Belgium)

    2016-03-15

    To compare the diagnostic accuracy of {sup 111}In-pentetreotide-scintigraphy with {sup 68}Ga-DOTATOC-positron emission tomography (PET)/computed tomography (CT) in patients with metastatic-neuroendocrine tumour (NET) scheduled for peptide receptor radionuclide therapy (PRRT). Incremental lesions (ILs) were defined as lesions observed on only one modality. Fifty-three metastatic-NET-patients underwent {sup 111}In-pentetreotide-scintigraphy (24 h post-injection; planar+single-photon emission CT (SPECT) abdomen) and whole-body {sup 68}Ga-DOTATOC-PET/CT. SPECT and PET were compared in a lesion-by-lesion and organ-by-organ analysis, determining the total lesions and ILs for both modalities. Significantly more lesions were detected on {sup 68}Ga-DOTATOC-PET/CT versus {sup 111}In-pentetreotide-scintigraphy. More specifically, we observed 1,098 lesions on PET/CT (range: 1-105; median: 15) versus 660 on SPECT (range: 0-73, median: 9) (p<0.0001), with 439 PET-ILs (42/53 patients) and one SPECT-IL (1/53 patients). The sensitivity for PET/CT was 99.9 % (95 % CI, 99.3-100.0), for SPECT 60.0 % (95 % CI, 48.5-70.2). The organ-by-organ analysis showed that the PET-ILs were most frequently visualized in liver and skeleton. Ga-DOTATOC-PET/CT is superior for the detection of NET-metastases compared to {sup 111}In-pentetreotide SPECT. (orig.)

  13. Tumor and infection localization in AIDS patients: Ga-67 and Tl-201 findings.

    Science.gov (United States)

    Turoglu, H T; Akisik, M F; Naddaf, S Y; Omar, W S; Kempf, J S; Abdel-Dayem, H M

    1998-07-01

    Examples of Ga-67 and Tl-201 scans in AIDS patients performed at St. Vincent's Hospital and Medical Center of New York are presented. Use of these methods is the adopted approach at this institution in AIDS patients for localizing sites of tumor or infection involvement. A Ga-67 scan is the most common nuclear medicine examination performed on AIDS patients. Sequential Tl-201 and Ga-67 scans have a role in differentiating Kaposi's sarcoma from malignant lymphoma and opportunistic infections. For intracranial lesions, Tc-99m MIBI or Tl-201-201-201-201 chloride can differentiate malignant from benign inflammatory lesions.

  14. 67Ga imaging in the patients with infective endocarditis after surgery for congenital heart disease

    International Nuclear Information System (INIS)

    Kohata, Tohru; Ono, Yasuo; Kamiya, Tetsuro; Nishimura, Tsunehiko; Takamiya, Makoto; Yagihara, Toshikatsu

    1991-01-01

    67 Ga imaging was performed in sixteen patients (age: 8 m.-18 y.) who had persistent fever and positive acute phase reactants after surgery for congenital heart disease. Abnormal uptake of 67 Ga over the heart and the lungs was evaluated with a computer. Abnormal uptake of 67 Ga was observed in seven patients. Of them, three showed it in the area of peripheral pulmonary artery and the other four showed it in the area of artificial vessels for pulmonary artery reconstruction. In six patients with positive blood cultures, five showed abnormal uptake of 67 Ga and in ten patients with negative blood cultures, two showed it. Vegetation was detected with 2D-echocardiography in four patients and all of them showed abnormal uptake of 67 Ga, while in 12 patients without vegetation three showed it. In conclusion, 67 Ga imaging was useful to detect the foci of infective endocarditis or pulmonary embolism caused by the vegetation in infective endocarditis in the patients after surgery for congenital heart disease, especially in the peripheral pulmonary arteries and artificial vessels which could not be detected with 2D-echo. (author)

  15. Labeling of monoclonal antibodies with a 67Ga phenolic aminocarboxylic acid chelate. Pt. 2

    International Nuclear Information System (INIS)

    Matzku, S.; Schuhmacher, J.; Kirchgessner, H.; Brueggen, J.

    1986-01-01

    Coupling of the 67 Ga-P-EDDHA chelate via carbodiimide to the anti-melanoma monoclonal antibody (MAb) M.2.9.4 resulted in a low degree of oligomerization, but a considerable degree of intra-molecular (inter-chain) cross-linking. However, this did not impair immunoreactivity, nor did the half-life in vivo differ substantially from that of 131 I-M.2.9.4. Biodistribution analysis in normal mice showed Ga:I ratios near 1 in the blood and other tissues not involved in degradation and label excretion. In tissues of the reticulo-endothelial system (RES) and the kidneys, Ga:I ratios up to 2.51 were reached within 4 days of administration. In antigen-positive MeWo tumor tissue, retention of 67 Ga also exceeded that of 131 I, so that tumor : organ ratios (except tumor : liver) were superior for the 67 Ga-labeled MAb. It is concluded that the method of coupling pre-established 67 Ga-P-EDDHA chelate to antibody, results in a functionally intact tracer molecule, whose persistence in vivo is not significantly impaired. The major difference to I-labeled MAbs may be prolonged retention of Ga in tissues (cells) physiologically involved in antibody catabolism. (orig.)

  16. Affinity of 169Yb, 67Ga and 111In for malignant tumor, (1)

    International Nuclear Information System (INIS)

    Ando, Itsuko

    1975-01-01

    The tumor affinity of 169 Yb-citrate, 67 Ga-citrate and 111 In-citrate was examined by using Yoshida sarcoma-bearing rats, and the affinity of these compounds for inflammation was also tested using rats with inflammation induced by croton oil injection. In this investigation there was no great difference in uptake by the tumor tissue of these compounds, but a great difference was observed in the retention value of the blood and uptake rate in the bone. 169 Yb-citrate was cleared rapidly from the blood and was taken mostly into the bone. So the retention values in the soft tissues became very small. On the other hand, 111 In-citrate was slowly and only slightly taken into the bone from the blood, so the retention values in the soft tissue remained relatively high. 67 Ga-citrate showed the intermediate value between the bone uptake rate of 169 Yb-citrate and that of 111 In-citrate. In the following experiments, 169 Yb-citrate and 67 Ga-citrate were compared in four strains: Yoshida sarcoma, Walker carcinosarcoma 256, Sarcoma 180, and Ehrlich tumor. The uptake rate of 169 Yb in tumor tissue was much larger than that of 67 Ga in Ehrlich tumor-bearing mice, but the value of 169 Yb was slightly smaller than those of 67 Ga in Yoshida sarcoma-bearing rats, Walker carcinosarcoma 256-bearing rats and Sarcoma 180-bearing mice. Tumor to organ ratios of 169 Yb, which were most important for tumor scanning, were much larger than those of 67 Ga in all four strains except tumor to bone ratios of 169 Yb. From the above-described facts, it was shown that 169 Yb-citrate had a stronger tumor affinity than 67 Ga-citrate and that the tumor affinity of 169 Yb-citrate was similar in these four strains of tumor bearing animals. These three compounds had a relatively strong affinity with the inflammatory tissue. (auth.)

  17. Uptake of 67Ga in the heart of rats treated with isoproterenol

    International Nuclear Information System (INIS)

    Sasaki, T.; Kojima, S.; Kubodera, A.

    1982-01-01

    Gallium-67 citrate ( 67 Ga) accumulation and various enzyme activities during the repair of rat heart with infarct-like lesions induced by isoproterenol (ISP) treatment were measured for 10 days after treatment. Serum creatine phosphokinase (CPK) and glutamic oxalacetic transaminase (GOT) activities were increased immediately after ISP treatment, reaching maximum levels of activity of 545+-64 U/ml and 542+-94 KU/ml, respectively, within 12 h. Uptake of 67 Ga in the rat heart was elevated 12 h after ISP treatment, reaching a maximum on day 1 (0.267+-0.020% dose/g heart). This pattern was essentially similar to the pattern of uronic acid content in the 1.2 M NaCl fraction, which contained mainly heparan sulfate (HS). The activity of glucose-6-phosphate dehydrogenase (G-6-PDH), a marker enzyme for fibrogenesis of damaged tissues, was also elevated 12 h after the ISP treatment, reaching a maximum of approximately 2.47 times that of the control heart on day 1. On the other hand, there were no significant changes in the 67 Ga uptake and uronic acid content in any of the fractions of the liver and kidneys. These findings suggested that HS might be an acceptor for 67 Ga accumulation during the repair of rat heart with infarct-like lesions, in accord with our previous results on CCl 4 -damaged rat liver. (orig.)

  18. Present and future of the hybrid imaging method SPECT/CT

    International Nuclear Information System (INIS)

    Kostadinova, I.

    2013-01-01

    Full text: Introduction: Based on the data in the literature and on our 4 year clinical experience applied for the first time in our country hybrid imaging - single photon emission tomography combined with computed tomography (SPECT / CT) it is clear that to obtain comprehensive information about the function and structure of the studied organ; the time for the diagnosis and thus the start of adequate treatment become shorter. The resulting scintigraphic image is with better quality due to CT correction of ‘diffusion’ gamma radiation, which leads to greater diagnostic accuracy. What you will learn: complex imaging method is used mainly in the field of endocrinology, cardiology, oncology, orthopedics, pulmology, neurology, and neurosurgery. It can be prove a given disease by visualization and localization of the organ lesions and determine the stage of the tumor process, to plan the type of subsequent treatment, to follow the effects of the therapy, and to predict the effect of an interventional or miniinvasive surgical procedure. Discussion: The result of the application of the hybrid imaging method is a change in the interpretation of more than half of the studied patients and in the treatment in more than a quarter of them. Conclusion: The clinical indications for SPECT/CT, and evidence of increased diagnostic accuracy compared with self- administered scintigraphic or CT methods are continuous expanded

  19. Influence of PET/CT 68Ga somatostatin receptor imaging on proceeding with patients, who were previously diagnosed with 99mTc-EDDA/HYNIC-TOC SPECT.

    Science.gov (United States)

    Madrzak, Dorota; Mikołajczak, Renata; Kamiński, Grzegorz

    2016-01-01

    The aim of this study was the assessment of utility of somatostatin receptor scintigraphy (SRS) by SPECT imaging using 99mTc-EDDA/HYNIC-Tyr3-octreotide (99mTc-EDDA/HYNIC-TOC) in patients with neuroendocrine neoplasm (NEN) or suspected NEN, referred to Nuclear Medicine Dept. of Voivodship Specialty Center in Rzeszow. The selected group of patients was referred also to 68Ga PET/CT. The posed question was the ratio of patients for whom PET/CT with 68Ga would change their management. The distribution of somatostatin receptors was imaged using 99mTc-EDDA/HYNIC-TOC in 61 planar and SPECT studies between 13/05/2010 and 04/02/2013 in Nuclear Medicine Dept. of Voivodship Specialty Center in Rzeszow. The patient age was within a range of 17-80, with the average age of 57.6. The average age of women (65% of patients over-all) was 55.6 and the average age of men (35% of patients overall) was 61.4. In 46 participants (75% of the study group), that underwent SRS, NEN was documented using pathology tests. Selected patients were referred to PET/CT with 68Ga labeled somatostatin analogs, DOTATATE or DOTANOC. This study group consisted of 14 female and 10 male participants with age range of 35-77 and average age of 55.5 years. Patients were classified into 3 groups, as follows: detection - referral due to clinical symptoms and/or biochemical markers (CgA-Chromogranin A, IAA-indoleacetic acid) with the aim of primary diagnosis, staging - referral with the aim of assessment of tumor spread, and follow-up - assessment of the therapy. Out of 61 patients, 24 underwent both 99mTc-EDDA/HYNIC-Tyr3-octreotide SPECT and 68Ga PET/CT. The result of PET/CT was used as a basis for further evaluation. Therefore, the patients were divided into groups; true positive TP (confirmed presence of tissue somatostatin receptors with 68Ga PET/CT) and TN (68Ga PET/CT did not detect any changes and the results were comparable and had the same influence on treatment protocol). In case of SPECT, the results

  20. Usefulness of 67Ga scintigraphy in deciding surgical indication in secondary hyperparathyroidism

    International Nuclear Information System (INIS)

    Otsuka, Nobuaki; Mimura, Hiroaki; Sone, Teruki; Tamada, Tsutomu; Yanagimoto, Shinichi; Tomomitsu, Tatsushi; Fukunaga, Masao; Katagiri, Makoto

    1999-01-01

    In order to evaluate the usefulness in deciding surgical indication in secondary hyperparathyroidism (SHP), 67 Ga scintigraphy was performed in 37 patients of SHP before parathyroidectomy (PTx). The radionuclide accumulation in skull and submandible was classified into 4 patterns (skull-submandibular pattern, skull pattern, submandibular pattern and normal pattern). Serum alkaline phosphatase levels were significantly elevated in patients of skull-submandibular pattern (13 cases) compared with skull pattern (6 cases), submandibular pattern (6 cases) and normal pattern (12 cases). Serum intact parathyroid hormone levels were significantly elevated in patients of skull-submandibular and skull patterns compared with normal pattern. No significant difference was observed among the weight of resected parathyroid glands. In 4 of 6 patients of normal pattern on 67 Ga scintigram, bone scintigraphy showed a characteristic pattern of SHP including an increased accumulation in the skull and submandible. Bone mineral density (BMD) in the distal radius was increased within six to twelve months after PTx in 10 of 11 patients of skull-submandibular pattern on 67 Ga scintigram, whereas only one patient showed an increase in BMD in 9 patients of normal pattern. In summary, it was concluded that 67 Ga scintigraphy could provide a useful information in deciding the indication for PTx in secondary hyperparathyroidism. (author)

  1. Technetium-99m-labelled red blood cell imaging in the diagnosis of hepatic haemangiomas: the role of SPECT/CT with a hybrid camera

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, Orazio; Danieli, Roberta; Manni, Carlo; Capoccetti, Francesca; Simonetti, Giovanni [Department of Biopathology and Diagnostic Imaging, University ' ' Tor Vergata' ' , Rome (Italy)

    2004-07-01

    Delayed liver single-photon emission computed tomography (SPECT) after {sup 99m}Tc red blood cell (RBC) labelling is helpful in detecting hepatic haemangiomas; however, diagnosis can be difficult when lesions are situated adjacent to structures like the inferior vena cava, the heart or hepatic vessels, where blood activity persists. The aims of this study were to evaluate the usefulness of RBC SPECT and transmission computed tomography (RBC SPECT/CT) performed simultaneously with a hybrid imaging system for correct characterisation of hepatic lesions in patients with suspected haemangioma, and to assess the additional value of fused images compared with SPECT alone. Twelve patients with 24 liver lesions were studied. The acquisitions of both anatomical (CT) and functional (SPECT) data were performed during a single session. SPECT images were first interpreted alone and then re-evaluated after adding the transmission anatomical maps. Image fusion was successful in all patients, with perfect correspondence between SPECT and CT data, allowing the precise anatomical localisation of sites of increased blood pool activity. SPECT/CT had a significant impact on results in four patients (33.3%) with four lesions defined as indeterminate on SPECT images, accurately characterising the hot spot foci located near vascular structures. In conclusion, RBC SPECT/CT imaging using this hybrid SPECT/CT system is feasible and useful in the identification or exclusion of suspected hepatic haemangiomas located near regions with high vascular activity. (orig.)

  2. Differential diagnosis of the pelvic masses by computed tomography and 67Ga-scintigraphy

    International Nuclear Information System (INIS)

    Sakai, Kiyoshi; Kamiya, Hirofumi; Nagai, Soichiro

    1986-01-01

    To differentiate between malignant and benign tumors, computed tomography (CT) and 67 Ga-scintigraphy were carried out on 40 patients having pelvic masses. The uptake of 67 Ga-citrate was divided into three groups: negative, suspicious and positive. Contrast enhancement (CE) was employed with CT. The increases in CT numbers after contrast enhancement were divided into three groups: no enhancement (0 to 20 HU), low enhancement (21 to 40 HU) and high enhancement (over 41 HU). The results were as follows: 1) 67 Ga negative group: out of 18 patients, there was only one patient with ovarian carcinoma. The lesion was too small to detect by CT. All the remaining 17 patients had benign tumors. The increased CT numbers in benign ovarian tumors were all within the range of no enhancement. On the other hand, the increases in CT number in myoma uteri were in the range of high enhancement. 2) 67 Ga suspicious group: in 3 of 10 patients, ovarian carcinomas were detected. Because the carcinoma tissues had low enhanced CT numbers after CE, they were easily differentiated from the benign tumors. 3) 67 Ga positive group: out of 12 patients, there were 3 patients with inflammatory disease. The increases in CT numbers in the inflammatory tissue were in the range of high enhancement, so they could be clearly differentiated from malignant tissues which ranged in low enhanced CT numbers. There were no benign tumors in this group. (author)

  3. Thyroid uptake of 67Ga-citrate is associated with thyroid autoimmunity and hypothyroidism in patients with sarcoidosis

    International Nuclear Information System (INIS)

    Antonelli, Alessandro; Fallahi, Poupak; Ferrari, Silvia Martina; Ferrannini, Ele; Fazzi, Piera; Grosso, Mariano; Boni, Giuseppe; Mariani, Giuliano

    2009-01-01

    To evaluate the association of gallium-67 ( 67 Ga)-citrate thyroid uptake with the presence of thyroid disorders in patients with sarcoidosis (S patients). Eighty-four S patients were evaluated by a complete thyroid work-up (neck ultrasound, circulating thyroid hormones and anti-thyroid antibodies, fine-needle aspiration). In S patients with 67 Ga thyroid uptake (respect those without): serum thyroid-stimulating hormone, the titre of anti-thyroid peroxidase (AbTPO) and/or anti-thyroglobulin antibodies (AbTg), and the prevalence of S patients with hypothyroidism or with positive AbTg or AbTPO was significantly higher; a thyroid hypoechoic pattern was more frequent. The prevalence of thyroid nodules was not significantly different between the two groups. Two cases of papillary thyroid cancer were observed in S patients without 67 Ga thyroid uptake, whilst no case in those with 67 Ga thyroid uptake. 67 Ga thyroid uptake is associated with the presence of aggressive autoimmune thyroiditis and hypothyroidism in S patients; thyroid function and ultrasonography should be performed in the presence of 67 Ga thyroid uptake. (orig.)

  4. Stimulated Emission from InAs (GaAs Monolayers Stacks Embedded in Al0.33Ga0.67As Ective Region

    Directory of Open Access Journals (Sweden)

    Dusan Pudis

    2002-01-01

    Full Text Available Our study is focused on the optical and electronic properties of InAs (GaAs monolayers embedded in Al0.33GA0.67As barrier layers investigated by temperature dependencies of electroluminescence spectra. The experimental results obtained from low temperature electroluminescence measurements of InAs (GaAs/Al0.33GA0.67As revealed the excellent emission spectra in the visib le range 630-690 nm. The stimulated emission from these structures across their cleavage planes has been observed at low  temperatures what is highly interesting for potential device applications.

  5. Basic evaluation of 67Ga labeled digoxin derivative as a metal-labeled bifunctional radiopharmaceutical

    International Nuclear Information System (INIS)

    Fujibayashi, Yasuhisa; Konishi, Junji; Takemura, Yasutaka; Taniuchi, Hideyuki; Iijima, Naoko; Yokoyama, Akira.

    1993-01-01

    To develop metal-labeled digoxin radiopharmaceuticals with affinity with anti-digoxin antibody as well as Na + , K + -ATPase, a digoxin derivative conjugated with deferoxamine was synthesized. The derivative had a high binding affinity with 67 Ga at deferoxamine introduced to the terminal sugar ring of digoxin. The 67 Ga labeled digoxin derivative showed enough in vitro binding affinity and selectivity to anti-digoxin antibody as well as Na + , K + -ATPase. The 67 Ga labeled digoxin derivative is considered to be a potential metal-labeled bifunctional radiopharmaceutical for digoxin RIA as well as myocardial Na + , K + -ATPase imaging. (author)

  6. sup 67 Ga imaging in the patients with infective endocarditis after surgery for congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Kohata, Tohru; Ono, Yasuo; Kamiya, Tetsuro; Nishimura, Tsunehiko; Takamiya, Makoto; Yagihara, Toshikatsu [National Cardiovascular Center, Suita, Osaka (Japan)

    1991-11-01

    {sup 67}Ga imaging was performed in sixteen patients (age: 8 m.-18 y.) who had persistent fever and positive acute phase reactants after surgery for congenital heart disease. Abnormal uptake of {sup 67}Ga over the heart and the lungs was evaluated with a computer. Abnormal uptake of {sup 67}Ga was observed in seven patients. Of them, three showed it in the area of peripheral pulmonary artery and the other four showed it in the area of artificial vessels for pulmonary artery reconstruction. In six patients with positive blood cultures, five showed abnormal uptake of {sup 67}Ga and in ten patients with negative blood cultures, two showed it. Vegetation was detected with 2D-echocardiography in four patients and all of them showed abnormal uptake of {sup 67}Ga, while in 12 patients without vegetation three showed it. In conclusion, {sup 67}Ga imaging was useful to detect the foci of infective endocarditis or pulmonary embolism caused by the vegetation in infective endocarditis in the patients after surgery for congenital heart disease, especially in the peripheral pulmonary arteries and artificial vessels which could not be detected with 2D-echo. (author).

  7. Colon transit scintigraphy by 67 Ga citrate for idiopathic constitution

    International Nuclear Information System (INIS)

    Neshandar Asll, I.; Ehsani, M.J.; Javadi, H.

    2005-01-01

    Background/objective: segmental colonic transit studies are important in patients with severe constipation. This study is the first Iranian preliminary survey of colonic transit scintigraphy using 67 Ga -citrate as a new method in constipated patients with normal radiographic and colonoscopic evaluations. Patients and methods: thirteen patients with idiopathic constipation underwent colon transit scintigraphy. After oral administration of 6-7 MBq Ga-citrates, serial abdominal images were taken up to 72 hours. Pattern classification wa s performed visually according to the distribution of radioactivity, Scintigraphic parameters such as geometric mean center of seq mental retention of tracer, as well as mean ac activity profiles and colonic tracer half-clearance time were calculated Results: Three patterns of colonic transit scintigraphy were recognized. Nine patients had the normal pattern, i.e. excellent propagation of ac activity. Three patients had the colonic inertia pattern with marked retention of activity in the transverse colon and splenic flexure at 48 hours, One patient had significant retention of activity in the recto sigmoid at 72 hours, defined as functional recto sigmoid obstruction . No significant difference was seen in GMC24h between the normal pattern and colonic inertia (P4.053), but GMC48h and GMC72h markedly differed between the two groups (P50.0 16 and 0.025 respectively). 'The mean half clearance time of the two groups was di different (P4.017). Our results are well compatible with scintigraphic diagnostic criteria in different patterns of colonic transit defined by other studies with different radiotracer. Conclusion: oral 67 Ga -citrate colon transit scintigraphy is a feasible method to evaluate idiopathic constipation and seems to be a suitable surrogate for radio-opaque markers. Keywords: oral 67 Ga -citrate, colonic transit study, idiopathic constipation, scintigraphy

  8. Biological effectiveness of /sup 67/Ga relative to external x-rays

    International Nuclear Information System (INIS)

    Rao, D.V.; Mylavarapu, V.B.; Govelitz, G.F.; Sastry, K.S.R.; Howell, R.W.

    1987-01-01

    As a consequence of electron-capture decay, /sup 67/Ga emits several low energy electrons. The dosimetry of such Auger-emitters in vivo is of considerable interest. The effects of /sup 67/Ga-citrate are investigated using gametogenesis in male and female mice as the experimental models. Spermatogonial cells in mouse testes and primary oocytes in mouse ovary are very sensitive to radiation. Damage caused to spermatogonial cells can be observed as reduced number of sperm heads after a defined period of time, whereas the reduction in the primary oocytes can be readily counted following simple histological procedures. The sperm head survival curve with internally administered /sup 67/Ga-citrate gave a D/sub o/ value of 42 cGy. This value for primary oocyte survival is found to be 4.5 cGy. With external 120 kVp X-rays, the corresponding D/sub o/ values are 67 cGy for the testis and 8.5 cGy for the ovary. The values of relative biological effectiveness are therefore 1.6 and 1.9 respectively. These observed higher RBE values suggest that the conventional MIRD procedure to calculate the absorbed doses is insufficient and the localized deposition of energy at the cellular level must be taken into consideration

  9. Study of subcellular distribution of /sup 67/Ga in tumor and liver

    Energy Technology Data Exchange (ETDEWEB)

    Ando, A; Takeshita, M; Hiraki, T [Kanazawa Univ. (Japan). School of Paramedicine; Ando, T; Hisada, K

    1977-02-01

    The following animals and transplanted tumors were used: rats implanted with Yoshida sarcoma and hepatoma AH109A, and mice implanted with Ehrlich tumor. /sup 67/Ga-citrate was injected into the rats intravenously and into the mice intraperitoneally. Ten minutes to 48 hours after the administration of /sup 67/Ga-citrate, the animals were sacrificed, and the tumor tissues and liver were excised. Subcellular fractionation of tumor tissues and livers was carried out according to the method of Hogeboom and Schneider. Radioactivity of each fraction was counted with a well type scintillation counter, and the protein of each fraction was measured according to Lowry's method. In Yoshida sarcoma and Ehrlich tumor, most of the radioactivity was localized in the supernatant fraction, and a small amount of radioactivity was localized in the mitochondrial fraction (lysosome contains in this fraction). But in the liver, most of the radioactivity was concentrated in the mitochondrial fraction, and the radioactivity of this fraction was increased with the passage of time after administration. Twenty-four hours later, about 50% of the total radioactivity was accumulated in this fraction. In the case of hepatoma AH109A, radioactivity of the mitochondrial fraction was increased with the passage of time after administration, and about 30% of total activity was concentrated in this fraction at 24 hours after administration. From these results it is concluded that the lysosome does not play an important role in the concentration of /sup 67/Ga in the tumor, but that the lysosome plays an important role in the concentration of /sup 67/Ga in the liver. In the case of hepatoma AH109A, it is presumed that the lysosome plays a very important role in the concentration of /sup 67/Ga in the tumor, hepatoma AH109A having some nature of liver.

  10. Using Ga-67/68-DOTATOC for pretherapeutic dosimetry

    International Nuclear Information System (INIS)

    Hofmann, M.; Fitschen, J.; Oei, M.L.; Boerner, A.R.; Knoop, B.O.; Otto, D.; Maecke, H.; Geworski, L.; Knapp, W.H.; Kalbacher, H.

    2002-01-01

    Full text: To date, treatment of somatostatin-positive tumors using Y-90-radiopeptide therapy has gained importance. Because accurate dosimetry is a prerequisite for proper treatment the most precise determination of maximum uptake and the measurement of tracer half-life in tumors and organs is highly desirable. In 12 patients we performed Ga-68-DOTATOC PET and measured the SUVs in tumors and organs 90 min p.i. as maximum tumor uptake. One day later Ga-67-DOTATOC planar scintigraphy (and SPET) were performed 2 / 24 / 48 h p.i.. Organs and tumors were evaluated by ROI techniques yielding in the corresponding half-lives. Absorbed doses were calculated according to MIRD 3.0. SUV varied for liver tumors from 5-15 and from 3 to 9 for bone metastases. The standardized uptake values of organ were 0.8 to 2.5 for liver, 4-10 for spleen and 3-6 for kidneys. The calculated doses varied in a relative broad range (intra- and interindividually). Over all small tumors (< 3 cm) displayed the most uptake and therefore yielded in the highest doses per injected MBq. Dosimetry using 67/68-Ga-DOTATOC PET and planar scintigraphy is feasible and yields in dosimetric data, which may help to adjust injected doses for adequate tumor treatment and avoid unwanted organ toxicity in future therapeutical trials. (author)

  11. Deposition and retention of 67Ga-labelled diesel particles in Fischer-344 rats

    International Nuclear Information System (INIS)

    Wolff, R.K.; Sun, J.D.; Lopez, J.A.; Wolf, I.; Cheng, Y.S.; McClellan, R.O.

    1981-01-01

    Fischer-344 rats were exposed nose-only to 67 Ga radiolabeled diesel exhaust particles produced from a 1 cylinder engine and diluted 10:1 with filtered air. Volume median diameters of the particles were 0.14 to 0.16 μm measured using an electrical aerosol analyzer, a diffusion battery and a cascade impactor. Initial lung deposition was 7 +- 2% and 12 +- 2% in two separate experiments. Gallium-67 left the lung rapidly with a clearance half-time of about 10 days, indicating that the 67 Ga label dissociated from diesel particles

  12. Comparison of thallium-201 ({sup 201}TI) and gallium-67 ({sup 67}Ga) scintigraphy in the evaluation of non-Hodgkin`s lymphoma (NHL) involving bone

    Energy Technology Data Exchange (ETDEWEB)

    Roach, P.J.; Janicek, M.J.; Kaplan, W.D. [Dana-Farber Cancer Institute and Harvard Medical School, Boston, MA (United States)

    1998-03-01

    Full text: The role of {sup 201}TI scintigraphy in the assessment of bone Iymphoma is unknown {sup 201}TI may more accurately reflect tumour burden than bone scan ({sup 99m}Tc MDP) or {sup 67}Ga and may better demonstrate both response to therapy and tumour recurrence. We compared planar {sup 67}Ga (320-400 MBq) and {sup 201}TI ((80-120 MBq)) scintigraphy (18 studies) in 5 patients (age 23-56 years) with NHL involving bone (4 intermediate grade, 1 high grade) to evaluate 19 clinical or radiographically positive sites. Pairs of studies were compared to {sup 99m}Tc-MDP in two patients (5 studies). A mean of four days (range 0-20 days) intervened between studies. Site intensity was scored with respect to cardiac ({sup 201}Tl) and sternal ({sup 67}Ga) uptake and sequential changes recorded by two physicians blinded to clinical history and results of other investigations. Except for one patient, lesions were {sup 201}TI avid on baseline studies. In all patients (12 sites; 11 studies) with clinical and radiographic evidence of remission, response was demonstrated earlier and sites became normal sooner with {sup 201}TI than {sup 67}Ga. In the one patient (1 site) with biopsy-proven recurrence, thallium-201 showed recurrence earlier than {sup 67}Ga or {sup 99m}Tc-MDP. Tumour recurrence was demonstrated only by {sup 67}Ga in the one patient (3 studies; 7 sites) with high grade NHL which was {sup 201}TI negative at baseline. This small series suggests that in patients with NHL involving bone (i) {sup 201}Tl scintigraphy is more useful than {sup 67}Ga in showing response to treatment; (ii) {sup 201}TI may predict recurrence earlier than {sup 67}Ga; and (iii) {sup 201}TI may not be of use in follow-up studies if lesions are {sup 201}TI negative on baseline studies.

  13. Skull base osteomyelitis: role of three phase and hybrid SPECT/CT bone scintigraphy

    International Nuclear Information System (INIS)

    Chakraborty, D.; Bhattacharaya, A.; Kamaleshwaran, K.K.; Mittal, B.R.; Aggarwal, K.; Singh, B.; Bhoil, A.

    2010-01-01

    Full text: Skull base osteomyelitis is the infection that has spread to the skull base, beyond the external auditory canal and seen in advanced stage of malignant otitis externa. Early diagnosis of this condition includes the use of bone scintigraphy since clinical assessment alone cannot differentiate the skull base osteomyelitis from the severe type of otitis externa in which there is no extension to the adjacent bone. Objective: To determine the role of three phase bone scintigraphy and delayed SPECT/CT in detection of skull base osteomyelitis in patients with malignant otitis externa. Material and Methods: Clinical records of 20 patients (14 Males and 6 Females; mean age 72 yrs) of otitis externa with suspected skull base involvement referred for bone scintigraphies were analyzed retrospectively. Three phase bone scintigraphy was acquired under dual detector gamma camera after intravenous injection of 20 mCi (740 MBq) 99m Tc-MDP followed by SPECT/CT of the skull. Scintigraphic findings were compared with clinical symptoms, signs and diagnostic CT scan findings. Results: All the patients except one were diabetic and having elevated ESR. 18 patients presented with bilateral symptoms and rest unilateral. Cranial nerves were involved in 8 patients (40%). Ear discharge culture sensitivity report was found in three patients; it was positive for Pseudomonas aeruginosa for two patients and in Diptheroids for one. In 9 patients (45%) increased flow of tracer and 10 patients (50%) increased blood pool phase in the temporal region was found. Delayed phase images showed increased uptake in skull bone in 19 patients (95%). Hybrid SPECT/CT of the skull localized areas of increased tracer uptake to the mastoid part in 15 patients (75%), petrous part in 11 patients (55%), sphenoid in 3 patients (15%) and zygomatic bone in one patient (5%) with CT showing destructive changes in 5 patients (25%) which were corroborated with diagnostic CT findings. SPECT/CT along with three phase

  14. Cyclotron produced {sup 67}Ga, a potential radionuclide for diagnostic and therapeutic applications

    Energy Technology Data Exchange (ETDEWEB)

    Khandaker, Mayeen Uddin, E-mail: mu-khandaker@um.edu.my; Kassim, Hasan Abu [Department of Physics, University of Malaya, 50603 Kuala Lumpur (Malaysia); Haba, Hiromitsu [Nishina Center for Accelerator-Based Science, RIKEN, Wako, Saitama 351-0198 (Japan)

    2015-04-29

    Production cross-sections of the {sup nat}Zn(d,x){sup 67}Ga reactions have been measured from a 24-MeV deuteron energy down to the threshold by using a stacked-foil activation technique combined with HPGe γ-ray spectrometry. An overall good agreement is found with some of the earlier measurements, whereas a partial agreement is obtained with the theoretical data extracted from the TENDL-2013 library. Physical thick target yield for the {sup 67}Ga radionuclide was deduced using the measured cross-sections, and found in agreement with the directly measured yield available in the literature. This study reveals that a low deuteron energy (<11 MeV) cyclotron and an enriched {sup 66}Zn target could be used to obtain {sup 67}Ga in no carrier added form.

  15. Optimization of SPECT-CT Hybrid Imaging Using Iterative Image Reconstruction for Low-Dose CT: A Phantom Study.

    Directory of Open Access Journals (Sweden)

    Oliver S Grosser

    Full Text Available Hybrid imaging combines nuclear medicine imaging such as single photon emission computed tomography (SPECT or positron emission tomography (PET with computed tomography (CT. Through this hybrid design, scanned patients accumulate radiation exposure from both applications. Imaging modalities have been the subject of long-term optimization efforts, focusing on diagnostic applications. It was the aim of this study to investigate the influence of an iterative CT image reconstruction algorithm (ASIR on the image quality of the low-dose CT images.Examinations were performed with a SPECT-CT scanner with standardized CT and SPECT-phantom geometries and CT protocols with systematically reduced X-ray tube currents. Analyses included image quality with respect to photon flux. Results were compared to the standard FBP reconstructed images. The general impact of the CT-based attenuation maps used during SPECT reconstruction was examined for two SPECT phantoms. Using ASIR for image reconstructions, image noise was reduced compared to FBP reconstructions for the same X-ray tube current. The Hounsfield unit (HU values reconstructed by ASIR were correlated to the FBP HU values(R2 ≥ 0.88 and the contrast-to-noise ratio (CNR was improved by ASIR. However, for a phantom with increased attenuation, the HU values shifted for low X-ray tube currents I ≤ 60 mA (p ≤ 0.04. In addition, the shift of the HU values was observed within the attenuation corrected SPECT images for very low X-ray tube currents (I ≤ 20 mA, p ≤ 0.001.In general, the decrease in X-ray tube current up to 30 mA in combination with ASIR led to a reduction of CT-related radiation exposure without a significant decrease in image quality.

  16. 67Ga in transferrin-unbound form is taken up by inflamed liver of mouse treated with CCl4

    International Nuclear Information System (INIS)

    Ohkubo, Yasuhito; Sasayama, Akio; Takegahara, Ikumi; Katoh, Shinsuke; Abe, Kenichi; Kohno, Hiroyuki; Kubodera, Akiko.

    1990-01-01

    In order to investigate whether or not transferrin is involved in the uptake of 67 Ga by inflamed liver (acute inflammatory tissues) the uptake of 67 Ga by the liver of mice treated with carbon tetrachloride (CCl 4 ) was studied. The serum GPT value reached its maximum on the 1st day after the CCl 4 treatment. The uptake of 67 Ga by the liver also reached its maximum on the 1st day after the CCl-4 treatment and the amount uptake into inflamed liver was about 6 times that uptaken into normal liver. On the other hand, the uptake of 125 I-transferrin into inflamed liver on the 1st day after CCl 4 treatment was only about 1.6 times that into normal liver. Moreover, cold Fe 3+ decreased the uptake of 67 Ga by normal liver but increased the uptake of 67 Ga by inflamed liver. These results show that transferrin plays an important role in the uptake of 67 Ga by normal liver but not by inflamed liver, i.e. 67 Ga in the transferrin-unbound form is preferentially taken up by inflamed liver. (author)

  17. Effect of iron deficiency on the biodistribution and tumor uptake of Ga-67 citrate in animals: concise communication

    International Nuclear Information System (INIS)

    Bradley, W.P.; Alderson, P.O.; Weiss, J.F.

    1979-01-01

    To investigate the effect of iron deficiency on the biodistribution and tumor uptake of Ga-67 citrate, 20 weanling Sprague-Dawley rats were maintained for 6 to 8 weeks on a low-iron diet. Eighteen littermates were maintained on a normal iron diet and served as controls. Animals received 10 μCi Ga-67 citrate, and urine and feces were collected for 48 h. The animals were then killed, tissue samples were obtained, and serum iron and unsaturated iron-binding capacity (UIBC) were measured. The accumulation of Ga-67 in the liver and spleen (% injected dose) was markedly increased in iron-deficient animals and urinary excretion was reduced. Tumor uptake was not significantly different in iron-deficient and control animals, but tumor-to-blood ratios were elevated (p < 0.001) in the iron-deficient animals because of low blood levels of Ga-67. The liver and spleen accumulation of Ga-67 correlated significantly (p < 0.001) with the UIBC. The results show that iron deficiency alters the distribution of Ga-67 citrate, and suggest that the variable liver-spleen uptake seen in clinical Ga-67 images may be explained, in part, by changes in serum iron and UIBC

  18. Labeling of monoclonal antibodies with a /sup 67/Ga phenolic aminocarboxylic acid chelate. Pt. 2. Comparison of immunoreactivity and biodistribution of monoclonal antibodies labeled with the /sup 67/Ga chelate or with /sup 131/I

    Energy Technology Data Exchange (ETDEWEB)

    Matzku, S.; Schuhmacher, J.; Kirchgessner, H.; Brueggen, J.

    1986-11-01

    Coupling of the /sup 67/Ga-P-EDDHA chelate via carbodiimide to the anti-melanoma monoclonal antibody (MAb) M.2.9.4 resulted in a low degree of oligomerization, but a considerable degree of intra-molecular (inter-chain) cross-linking. However, this did not impair immunoreactivity, nor did the half-life in vivo differ substantially from that of /sup 131/I-M.2.9.4. Biodistribution analysis in normal mice showed Ga:I ratios near 1 in the blood and other tissues not involved in degradation and label excretion. In tissues of the reticulo-endothelial system (RES) and the kidneys, Ga:I ratios up to 2.51 were reached within 4 days of administration. In antigen-positive MeWo tumor tissue, retention of /sup 67/Ga also exceeded that of /sup 131/I, so that tumor : organ ratios (except tumor : liver) were superior for the /sup 67/Ga-labeled MAb. It is concluded that the method of coupling pre-established /sup 67/Ga-P-EDDHA chelate to antibody, results in a functionally intact tracer molecule, whose persistence in vivo is not significantly impaired. The major difference to I-labeled MAbs may be prolonged retention of Ga in tissues (cells) physiologically involved in antibody catabolism.

  19. Thyroid uptake of {sup 67}Ga-citrate is associated with thyroid autoimmunity and hypothyroidism in patients with sarcoidosis

    Energy Technology Data Exchange (ETDEWEB)

    Antonelli, Alessandro; Fallahi, Poupak; Ferrari, Silvia Martina; Ferrannini, Ele [University of Pisa and CNR Institute of Clinical Physiology, Metabolism Unit, Department of Internal Medicine, Pisa (Italy); Fazzi, Piera [University of Pisa, Respiratory Pathophysiology Section, Cardiac and Thoracic Department, Pisa (Italy); Grosso, Mariano; Boni, Giuseppe; Mariani, Giuliano [University of Pisa, Regional Center of Nuclear Medicine, Medical School, Pisa (Italy)

    2009-01-15

    To evaluate the association of gallium-67 ({sup 67}Ga)-citrate thyroid uptake with the presence of thyroid disorders in patients with sarcoidosis (S patients). Eighty-four S patients were evaluated by a complete thyroid work-up (neck ultrasound, circulating thyroid hormones and anti-thyroid antibodies, fine-needle aspiration). In S patients with {sup 67}Ga thyroid uptake (respect those without): serum thyroid-stimulating hormone, the titre of anti-thyroid peroxidase (AbTPO) and/or anti-thyroglobulin antibodies (AbTg), and the prevalence of S patients with hypothyroidism or with positive AbTg or AbTPO was significantly higher; a thyroid hypoechoic pattern was more frequent. The prevalence of thyroid nodules was not significantly different between the two groups. Two cases of papillary thyroid cancer were observed in S patients without {sup 67}Ga thyroid uptake, whilst no case in those with {sup 67}Ga thyroid uptake. {sup 67}Ga thyroid uptake is associated with the presence of aggressive autoimmune thyroiditis and hypothyroidism in S patients; thyroid function and ultrasonography should be performed in the presence of {sup 67}Ga thyroid uptake. (orig.)

  20. Evaluation of hilar 67Ga-citrate uptake in bronchogenic carcinoma

    International Nuclear Information System (INIS)

    Matsuno, Noriyo; Kuyama, Junpei; Uchida, Yoshitaka; Hatano, Osamu; Imai, Yasunori; Uno, Kimiichi; Minoshima, Satoshi.

    1995-01-01

    We evaluated hilar uptake on 67 Ga-citrate scintigraphy and correlated with hilar lymph node metastases in one-hundred seventeen cases (two-hundred thirty four hila) of bronchogenic carcinoma. Hilar uptake was classified into three grades independently on anterior and posterior chest views: no uptake (grade 0), uptake equal to that in the thoracic vertebrae (grade 1), and uptake higher than that in the thoracic vertebrae (grade 2). If a summed grade of anterior and posterior view was larger than 3, hilar uptake was considered as positive. In forty-four cases (forty-nine hila) with hilar lymph node metastases, positive hilar uptake was found in ten cases (eleven hila), resulting in sensitivity of 22% based on cases and 23% based on hila. In seventy-three cases (one-hundred forty-six hila) without hilar lymph node metastases, positive hilar uptake was found in six cases (ten hila), resulting in specificity of 91% based on cases and 93% based on hila. In comparison to scintigraphic findings of unilaterally positive hilar uptake, findings of bilaterally positive hilar uptake showed significantly lower accuracy in determining presence of hilar lymph node metastases. No definite correlation between hilar uptake and histopathology or 67 Ga-citrate uptake in a primary tumor was observed. The results indicate that usefulness of 67 Ga-citrate scintigraphy is limited when evaluating hilar lymph node metastases in bronchogenic carcinoma. (author)

  1. Increased tumor uptake of 67Ga citrate following a course of picibanil (NSC-B116209)

    International Nuclear Information System (INIS)

    Okuyama, Shinichi; Matsuzawa, Taiju; Mishina, Hitoshi.

    1979-01-01

    Exposure to exponential dose schedules of OK-432, penicillin-inactivated preparation of streptococcus hemolyticus (NSC-B116209), resulted in an increased retention of 67 Ga citrate. Its uptake in footpad tumors of AH 109A was also increased. The results may suggest that pretreatment with OK-432 would increase tumor uptake of 67 Ga citrate and help scintigraphic delineation of malignancies in man. It may probably augment tumor concentration of anticancer chemotherapeutics, too. Thus, the tumor affinitive property of OK-432 can be taken advantage of in anticancer strategy as well as cancer detection by 67 Ga scanning. (author)

  2. Capacitive coupling in hybrid graphene/GaAs nanostructures

    Energy Technology Data Exchange (ETDEWEB)

    Simonet, Pauline, E-mail: psimonet@phys.ethz.ch; Rössler, Clemens; Krähenmann, Tobias; Varlet, Anastasia; Ihn, Thomas; Ensslin, Klaus; Reichl, Christian; Wegscheider, Werner [Solid State Physics Laboratory, ETH Zürich, 8093 Zürich (Switzerland)

    2015-07-13

    Coupled hybrid nanostructures are demonstrated using the combination of lithographically patterned graphene on top of a two-dimensional electron gas (2DEG) buried in a GaAs/AlGaAs heterostructure. The graphene forms Schottky barriers at the surface of the heterostructure and therefore allows tuning the electronic density of the 2DEG. Conversely, the 2DEG potential can tune the graphene Fermi energy. Graphene-defined quantum point contacts in the 2DEG show half-plateaus of quantized conductance in finite bias spectroscopy and display the 0.7 anomaly for a large range of densities in the constriction, testifying to their good electronic properties. Finally, we demonstrate that the GaAs nanostructure can detect charges in the vicinity of the heterostructure's surface. This confirms the strong coupling of the hybrid device: localized states in the graphene ribbon could, in principle, be probed by the underlying confined channel. The present hybrid graphene/GaAs nanostructures are promising for the investigation of strong interactions and coherent coupling between the two fundamentally different materials.

  3. Capacitive coupling in hybrid graphene/GaAs nanostructures

    International Nuclear Information System (INIS)

    Simonet, Pauline; Rössler, Clemens; Krähenmann, Tobias; Varlet, Anastasia; Ihn, Thomas; Ensslin, Klaus; Reichl, Christian; Wegscheider, Werner

    2015-01-01

    Coupled hybrid nanostructures are demonstrated using the combination of lithographically patterned graphene on top of a two-dimensional electron gas (2DEG) buried in a GaAs/AlGaAs heterostructure. The graphene forms Schottky barriers at the surface of the heterostructure and therefore allows tuning the electronic density of the 2DEG. Conversely, the 2DEG potential can tune the graphene Fermi energy. Graphene-defined quantum point contacts in the 2DEG show half-plateaus of quantized conductance in finite bias spectroscopy and display the 0.7 anomaly for a large range of densities in the constriction, testifying to their good electronic properties. Finally, we demonstrate that the GaAs nanostructure can detect charges in the vicinity of the heterostructure's surface. This confirms the strong coupling of the hybrid device: localized states in the graphene ribbon could, in principle, be probed by the underlying confined channel. The present hybrid graphene/GaAs nanostructures are promising for the investigation of strong interactions and coherent coupling between the two fundamentally different materials

  4. Uptake of /sup 67/Ga in the heart of rats treated with isoproterenol

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, T; Kojima, S; Kubodera, A

    1982-12-01

    Gallium-67 citrate (/sup 67/Ga) accumulation and various enzyme activities during the repair of rat heart with infarct-like lesions induced by isoproterenol (ISP) treatment were measured for 10 days after treatment. Serum creatine phosphokinase (CPK) and glutamic oxalacetic transaminase (GOT) activities were increased immediately after ISP treatment, reaching maximum levels of activity of 545+-64 U/ml and 542+-94 KU/ml, respectively, within 12 h. Uptake of /sup 67/Ga in the rat heart was elevated 12 h after ISP treatment, reaching a maximum on day 1 (0.267+-0.020% dose/g heart). This pattern was essentially similar to the pattern of uronic acid content in the 1.2 M NaCl fraction, which contained mainly heparan sulfate (HS). The activity of glucose-6-phosphate dehydrogenase (G-6-PDH), a marker enzyme for fibrogenesis of damaged tissues, was also elevated 12 h after the ISP treatment, reaching a maximum of approximately 2.47 times that of the control heart on day 1. On the other hand, there were no significant changes in the /sup 67/Ga uptake and uronic acid content in any of the fractions of the liver and kidneys. These findings suggested that HS might be an acceptor for /sup 67/Ga accumulation during the repair of rat heart with infarct-like lesions, in accord with our previous results on CCl/sub 4/-damaged rat liver.

  5. Changes of 67Ga-citrate accumulation in the rat liver during feeding with chemical carcinogen 3'-Methyl-4-dimethylaminoazobenzene

    International Nuclear Information System (INIS)

    Sasaki, Toru; Kojima, Shuji; Kubodera, Akiko.

    1982-01-01

    The changes of 67 Ga-citrate( 67 Ga) in the rat liver during feeding with chemical carcinogen 3'-methyl- 4-dimethylaminoazobenzene (3'-Me-DAB) were studied for 20 weeks. The results were shown as follows: Elevated 67 Ga accumulation in the rat liver was first observed at 3rd week after the start of 3'-Me-DAB feeding. There was decrease from the 3-week level at about the 6th week, followed by a sustained increase. The accumulation of 67 Ga in the gram liver at 20th week was about 2.3 times higher than that of the control. There was close correlation between the 67 Ga accumulation pattern and the patterns of the hepatic #betta#-glutamyltranspeptidase and glucose-6-phosphate dehydrogenase activities at l ate stages during hepatocarcinogenesis. In subcellular distribution of 67 Ga, remarkable changes were seen in 800 x g fraction. Grom these studies, it is suggested that 67 Ga may bind with components in 800 x g fraction, concerned with one pathological changes induced by 3'-Me-DAB. (author)

  6. Interest of the SPECT-CT hybrid imaging in the management of thyroid differentiated carcinomas; Interets de l'imagerie hybride TEMP-TDM dans la prise en charge des carcinomes differencies de la thyroide

    Energy Technology Data Exchange (ETDEWEB)

    Menemani, A.; Mebarki, M.; Slama, A.; Meghelli, S.; Lachachi, B.; Krim, M.; Berber, N. [CHU Tlemcen, Service de medecine nucleaire (Algeria)

    2010-07-01

    Purpose: Images merging, associating SPECT and CT, integers functional and anatomical data. The purpose of our study was to evaluate the SPECT contribution coupled to CT in our daily practice of the management thyroid differentiated carcinomas. Conclusions: SPECT/CT merging got by a hybrid system allows a better anatomical location and improves the diagnostic value of examination in the extension assessment of thyroid differentiated carcinomas. (N.C.)

  7. The influence of whole body 60Co-irradiation on distribution of 67Ga in tumor-bearing mice

    International Nuclear Information System (INIS)

    Wakao, Hiromi; Shimura, Akira; Higashi, Tomomitsu

    1981-01-01

    Since the initial findings that 67 Ga has a preferential affinity for soft tissue tumors, in humans numerous suggestions have been advanced for the basic mechanism involved. The effects produced by whole-body X-irradiation on the excretion and tissue distribution of 67 Ga have been reported by Swartzendruber and others. Bradley and coworkers have shown that these irradiation effects were associated with an increase in serum iron. The present investigation was undertaken in order to study the relationships between the change in the serum iron concentration and 67 Ga accumulation in the tumor and soft tissues in mice bearing Ehrlich's ascites tumor. The following results were obtained. (1) The serum iron concentration was significantly decreased between 3 and 6 hours after 10 Gy (1,000 rad) dose of whole-body 60 Co-irradiation. Subsequently, the serum iron levels were slowly elevated. (2) The uptake of 67 Ga in the tumor and soft tissues was increased if the serum iron concentration was decreased by whole-body 60 Co-irradiation during the early phase. On the contrary, if the serum iron concentration was high, the uptake of 67 Ga in the tumor was decreased. (3) The excretion of 67 Ga from the body was delayed if the serum iron concentration was decreased by whole-body 60 Co-irradiation. However, if the serum iron concentration was high, the excretion of 67 Ga from the body significantly increased. (author)

  8. The possibility of evaluation on inflammatory change at respiratory tract in chronic bronchial asthma using 67Ga scintigraphy

    International Nuclear Information System (INIS)

    Fukumitsu, Nobuyoshi; Uchiyama, Mayuki; Mori, Yutaka; Kawakami, Kenji; Kikuchi, Ichiro; Shimada, Takao.

    1997-01-01

    67 Ga scintigraphy was performed in 17 patients with chronic bronchial asthma to grasp the inflammatory change of respiratory tract. On 67 Ga scintigraphy, abnormal accumulations were detected on lung fields in 6 cases (35.3%) of 17 cases. In 5 cases of these 6 cases, the defect areas which were pointed out on 81m Kr ventilation scintigraphy were matched to the abnormal accumulation areas which were pointed out on 67 Ga scintigraphy. In dynamics, the abnormal accumulation areas which were pointed out on 67 Ga scintigraphy were matched to the defect areas which had been at all times pointed out on 81m Kr ventilation scintigraphy. 67 Ga scintigraphy was expected to be one of index to grasp the inflammatory change of respiratory tract in patients with chronic bronchial asthma. (author)

  9. Small-animal SPECT and SPECT/CT: application in cardiovascular research

    Energy Technology Data Exchange (ETDEWEB)

    Golestani, Reza; Dierckx, Rudi A.J.O. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Wu, Chao [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Utrecht, Image Sciences Institute and Rudolf Magnus Institute of Neurosciences, Utrecht (Netherlands); Tio, Rene A. [University Medical Center Groningen, Thorax Center, Department of Cardiology, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Zeebregts, Clark J. [University Medical Center Groningen, Department of Surgery, Division of Vascular Surgery, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Petrov, Artiom D. [University of California, Irvine, Division of Cardiology, School of Medicine, Irvine, California (United States); Beekman, Freek J. [University Medical Center Utrecht, Image Sciences Institute and Rudolf Magnus Institute of Neurosciences, Utrecht (Netherlands); Delft University of Technology, Faculty of Applied Sciences, Section Radiation Detection and Medical Imaging, Delft (Netherlands); MILabs, Utrecht (Netherlands); Boersma, Hendrikus H. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Groningen, Department of Clinical and Hospital Pharmacy, Hanzeplein 1, P.O. Box 30001, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Slart, Riemer H.J.A. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands)

    2010-09-15

    Preclinical cardiovascular research using noninvasive radionuclide and hybrid imaging systems has been extensively developed in recent years. Single photon emission computed tomography (SPECT) is based on the molecular tracer principle and is an established tool in noninvasive imaging. SPECT uses gamma cameras and collimators to form projection data that are used to estimate (dynamic) 3-D tracer distributions in vivo. Recent developments in multipinhole collimation and advanced image reconstruction have led to sub-millimetre and sub-half-millimetre resolution SPECT in rats and mice, respectively. In this article we review applications of microSPECT in cardiovascular research in which information about the function and pathology of the myocardium, vessels and neurons is obtained. We give examples on how diagnostic tracers, new therapeutic interventions, pre- and postcardiovascular event prognosis, and functional and pathophysiological heart conditions can be explored by microSPECT, using small-animal models of cardiovascular disease. (orig.)

  10. Small-animal SPECT and SPECT/CT: application in cardiovascular research

    International Nuclear Information System (INIS)

    Golestani, Reza; Dierckx, Rudi A.J.O.; Wu, Chao; Tio, Rene A.; Zeebregts, Clark J.; Petrov, Artiom D.; Beekman, Freek J.; Boersma, Hendrikus H.; Slart, Riemer H.J.A.

    2010-01-01

    Preclinical cardiovascular research using noninvasive radionuclide and hybrid imaging systems has been extensively developed in recent years. Single photon emission computed tomography (SPECT) is based on the molecular tracer principle and is an established tool in noninvasive imaging. SPECT uses gamma cameras and collimators to form projection data that are used to estimate (dynamic) 3-D tracer distributions in vivo. Recent developments in multipinhole collimation and advanced image reconstruction have led to sub-millimetre and sub-half-millimetre resolution SPECT in rats and mice, respectively. In this article we review applications of microSPECT in cardiovascular research in which information about the function and pathology of the myocardium, vessels and neurons is obtained. We give examples on how diagnostic tracers, new therapeutic interventions, pre- and postcardiovascular event prognosis, and functional and pathophysiological heart conditions can be explored by microSPECT, using small-animal models of cardiovascular disease. (orig.)

  11. {sup 68}Ga-DOTATATE PET/CT in recurrent medullary thyroid carcinoma: a lesion-by-lesion comparison with {sup 111}In-octreotide SPECT/CT and conventional imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yamaga, Lilian Yuri Itaya; Cunha, Marcelo L.; Campos Neto, Guilherme C.; Garcia, Marcio R.T.; Wagner, Jairo; Funari, Marcelo B.G. [Hospital Israelita Albert Einstein, Imaging Department, Sao Paulo (Brazil); Yang, Ji H.; Camacho, Cleber P. [Universidade Federal de Sao Paulo, Multiple Neoplasia Outpatiet Clinic, Sao Paulo (Brazil)

    2017-09-15

    The aim of this study was to prospectively compare the detection rate of {sup 68}Ga-DOTATATE PET-CT with {sup 111}In-octreotide SPECT-CT and conventional imaging (CI) in medullary thyroid carcinoma (MTC) patients with increased calcitonin (Ctn) levels but negative CI after thyroidectomy. Fifteen patients with raised Ctn levels and/or CI evidence of recurrence underwent {sup 68}Ga-DOTATATE PET-CT, {sup 111}In-octreotide SPECT-CT and CI. Histopathology, CI and biochemical/clinical/imaging follow-up were used as the reference standard. PET/CT, SPECT/CT and CI were compared in a lesion-based and organ-based analysis. PET/CT evidenced recurrence in 14 of 15 patients. There were 13 true positive (TP), 1 true negative (TN), 1 false positive (FP) and no false negative (FN) cases, resulting in a sensitivity and accuracy of 100% and 93%. SPECT/CT was positive in 6 of 15 cases. There were 6 TP, 2 TN, 7 FN and no FP cases, resulting in a sensitivity of 46% and accuracy of 53%. CI procedures detected tumor lesions in 14 of 15 patients. There were 13 TP, 1TN, 1 FP and no FN cases with a sensitivity of 100% and accuracy of 93%. A significantly higher number of lesions was detected by PET/CT (112 lesions, p = 0.005) and CI (109 lesions, p = 0.005) in comparison to SPECT/CT (16 lesions). There was no significant difference between PET/CT and CI for the total number of detected lesions (p = 0.734). PET/CT detected more lesions than SPECT/CT regardless of the organ. PET/CT detected more bone lesions but missed some neck nodal metastases evidenced by CI. The number of lesions per region demonstrated by PET/CT and CI were similar in the other sites. {sup 68}Ga-DOTATATE PET/CT is superior to {sup 111}In-octreotide SPECT/CT for the detection of recurrent MTC demonstrating a significantly higher number of lesions. {sup 68}Ga-DOTATATE PET/CT showed a superior detection rate compared to CI in demonstrating bone metastases. (orig.)

  12. Basic evaluation of [sup 67]Ga labeled digoxin derivative as a metal-labeled bifunctional radiopharmaceutical

    Energy Technology Data Exchange (ETDEWEB)

    Fujibayashi, Yasuhisa; Konishi, Junji (Kyoto Univ. (Japan). Faculty of Medicine); Takemura, Yasutaka; Taniuchi, Hideyuki; Iijima, Naoko; Yokoyama, Akira

    1993-11-01

    To develop metal-labeled digoxin radiopharmaceuticals with affinity with anti-digoxin antibody as well as Na[sup +], K[sup +]-ATPase, a digoxin derivative conjugated with deferoxamine was synthesized. The derivative had a high binding affinity with [sup 67]Ga at deferoxamine introduced to the terminal sugar ring of digoxin. The [sup 67]Ga labeled digoxin derivative showed enough in vitro binding affinity and selectivity to anti-digoxin antibody as well as Na[sup +], K[sup +]-ATPase. The [sup 67]Ga labeled digoxin derivative is considered to be a potential metal-labeled bifunctional radiopharmaceutical for digoxin RIA as well as myocardial Na[sup +], K[sup +]-ATPase imaging. (author).

  13. Comparison of TITAN hybrid deterministic transport code and MCNP5 for simulation of SPECT

    International Nuclear Information System (INIS)

    Royston, K.; Haghighat, A.; Yi, C.

    2010-01-01

    Traditionally, Single Photon Emission Computed Tomography (SPECT) simulations use Monte Carlo methods. The hybrid deterministic transport code TITAN has recently been applied to the simulation of a SPECT myocardial perfusion study. The TITAN SPECT simulation uses the discrete ordinates formulation in the phantom region and a simplified ray-tracing formulation outside of the phantom. A SPECT model has been created in the Monte Carlo Neutral particle (MCNP)5 Monte Carlo code for comparison. In MCNP5 the collimator is directly modeled, but TITAN instead simulates the effect of collimator blur using a circular ordinate splitting technique. Projection images created using the TITAN code are compared to results using MCNP5 for three collimator acceptance angles. Normalized projection images for 2.97 deg, 1.42 deg and 0.98 deg collimator acceptance angles had maximum relative differences of 21.3%, 11.9% and 8.3%, respectively. Visually the images are in good agreement. Profiles through the projection images were plotted to find that the TITAN results followed the shape of the MCNP5 results with some differences in magnitude. A timing comparison on 16 processors found that the TITAN code completed the calculation 382 to 2787 times faster than MCNP5. Both codes exhibit good parallel performance. (author)

  14. The diagnostic application of Ga-67 scintigraphy in primary lung cancer, hepatoma and abdominal abscess

    International Nuclear Information System (INIS)

    Oshiumi, Yoshihiko

    1983-01-01

    It is difficult to detect tumor lesions by 67 Gascintigraphy, though it is named as a tumor scintigraphy. Recently, 67 Ga-scintigraphy is well used in the detection of inflammatic lesions. This paper is to discuss the detectability of lesions and diagnostic limitation on operability by 67 Ga-scintigraphy to primary lung cancer, minute hepatoma and abdominal absccess. Primary lung cancer: In detecting metastatic hilar lymph nodes, the sensitivity is 54%, and the specificity is 78%. In detecting metastatic mediastinal lymph nodes, the sensitivity is 32% and the specificity is 89%. Minute hepatoma : The detectability depended on the size of the lesion. It is hard to detect lesions with under 2 cm by 67 Ga-scintigraphy. Abdominal abscess : The sensitivity is 88%, and the specificity is 92%. (author)

  15. Usefulness of hybrid SPECT/CT for the 99mTc-HMPAO-labeled leukocyte scintigraphy in a case of cranial osteomyelitis

    Directory of Open Access Journals (Sweden)

    Chiara Bruni

    Full Text Available Cranial osteomyelitis is a potentially fatal lesion. White blood cell scanning (WBC with 99mTc-hexamethylpropylene amine oxime (HMPAO has proven highly sensitive and specific in the diagnosis and follow-up of patients with suspected osteomyelitis. In this report we show the usefulness of SPECT and transmission CT performed simultaneously using a hybrid imaging device for the functional anatomic mapping of soft tissue and cranial bone infections. 99mTc-HMPAO-labeled leukocytes scintigraphy was performed on an elderly diabetic man with an intracranial mass lesion and with suspected temporal bone infection. Planar scans were acquired 30 min, 4 h, and 24 h after injection. SPECT/CT was obtained 6 h after tracer injection, using a dual-head camera coupled with a low-power X-ray tube. The scintigraphic results were matched with the results of surgery and of clinical follow-up. The planar images alone were true-positives for abscess in this patient. SPECT/CT improves the accuracy of99mTc-HMPAO scintigraphy especially in discriminating between soft-tissue and bone involvement. In fact, SPECT/CT also showed temporal bone osteomyelitis. This result indicates that SPECT/CT performed using a hybrid device can improve imaging with 99mTc-HMPAO-labeled leukocytes in patients with suspected osteomyelitis by providing accurate anatomic localization and precise definition of the extent of infection.

  16. The evaluation of the bone marrow accumulation of Ga-67 citrate

    Energy Technology Data Exchange (ETDEWEB)

    Ohnishi, Takashi; Jinnouchi, Seishi; Hoshi, Hiroaki; Yoshimura, Hiroshi; Nagamachi, Shigeki; Watanabe, Katsushi (Miyazaki Medical Coll., Kiyotake (Japan))

    1989-11-01

    The bone marrow distribution of Ga-67 citrate may be influenced by various elements in serum. In order to make these points clear, 1,955 whole body images were reviewed on the relationship between the accumulation of bone marrow and laboratory examination data of each patients. Increasing accumulation in the bone marrow was determined as positive when the bones of lower extremities were deposited on the images, because these bones was not visualized in normal gallium image. Laboratory data of 20 patients without having bone marrow accumulation was used as control. The positive findings of bone marrow accumulation was observed in 38 patients (2%) including 23 malignancies and 15 benign disease. The malignant tumor infiltration to the bone marrow was demonstrated by bone marrow aspiration biopsy in 2 out of 7 patients with bone marrow accumulation of Ga-67. Seven out of 15 patients with benign disease were collagen disease such as aortitis syndrome or SLE. The values of hemoglobin, hematocrit, serum iron and creatinine clearance were significantly lower in the patients with positive findings in comparison with control. These results suggest that the lower level of serum iron and anemia may cause increasing bone marrow accumulation of Ga-67 citrate. (author).

  17. The evaluation of the bone marrow accumulation of Ga-67 citrate

    International Nuclear Information System (INIS)

    Ohnishi, Takashi; Jinnouchi, Seishi; Hoshi, Hiroaki; Yoshimura, Hiroshi; Nagamachi, Shigeki; Watanabe, Katsushi

    1989-01-01

    The bone marrow distribution of Ga-67 citrate may be influenced by various elements in serum. In order to make these points clear, 1,955 whole body images were reviewed on the relationship between the accumulation of bone marrow and laboratory examination data of each patients. Increasing accumulation in the bone marrow was determined as positive when the bones of lower extremities were deposited on the images, because these bones was not visualized in normal gallium image. Laboratory data of 20 patients without having bone marrow accumulation was used as control. The positive findings of bone marrow accumulation was observed in 38 patients (2%) including 23 malignancies and 15 benign disease. The malignant tumor infiltration to the bone marrow was demonstrated by bone marrow aspiration biopsy in 2 out of 7 patients with bone marrow accumulation of Ga-67. Seven out of 15 patients with benign disease were collagen disease such as aortitis syndrome or SLE. The values of hemoglobin, hematocrit, serum iron and creatinine clearance were significantly lower in the patients with positive findings in comparison with control. These results suggest that the lower level of serum iron and anemia may cause increasing bone marrow accumulation of Ga-67 citrate. (author)

  18. Advantages of hybrid SPECT-CT imaging in preoperative localization of parathyroid glands in a patient with secondary hyperparathyroidism. A case report

    International Nuclear Information System (INIS)

    Cytawa, Wojciech; Teodorczyk, Jacek; Lass, Piotr

    2013-01-01

    Secondary hyperparathyroidism is a frequent complication of chronic renal failure. Patients resistant to pharmacotherapy are candidates for parathyroidectomy. Invasiveness of surgical treatment can be minimized by precise preoperative localization of parathyroid glands. Imaging modalities routinely used for this purpose are ultrasonography and MIBI-Tc99m scintigraphy. Our case report shows advantages of co-registered computer tomography and conventional SPECT imaging (SPECT/CT) in a patient with advanced secondary hyperparathyroidism successfully treated with surgery. Hybrid SPECT/CT parathyroid imaging enables better surgical planning and is superior to conventional scintigraphy

  19. Diagnostic application of Ga-67 scintigraphy in primary lung cancer, hepatoma and abdominal abscess. On surgical operation

    Energy Technology Data Exchange (ETDEWEB)

    Oshiumi, Yoshihiko (National Central Hospital of Fukuoka (Japan))

    1983-05-01

    It is difficult to detect tumor lesions by /sup 67/Ga-scintigraphy, though it is named as a tumor scintigraphy. Recently, /sup 67/Ga-scintigraphy is well used in the detection of inflammatic lesions. This paper is to discuss the detectability of lesions and diagnostic limitation on operability by /sup 67/Ga-scintigraphy to primary lung cancer, minute hepatoma and abdominal abscess. Primary lung cancer: In detecting metastatic hilar lymph nodes, the sensitivity is 54%, and the specificity is 78%. In detecting metastatic mediastinal lymph nodes, the sensitivity is 32% and the specificity is 89%. Minute hepatoma : The detectability depended on the size of the lesion. It is hard to detect lesions with under 2 cm by /sup 67/Ga-scintigraphy. Abdominal abscess : The sensitivity is 88%, and the specificity is 92%.

  20. Additional value of hybrid SPECT/CT systems in neuroendocrine tumors, adrenal tumors, pheochromocytomas and paragangliomas.

    Science.gov (United States)

    Wong, K K; Chondrogiannis, S; Fuster, D; Ruiz, C; Marzola, M C; Giammarile, F; Colletti, P M; Rubello, D

    The aim of this review was to evaluate the potential advantages of SPECT/CT hybrid imaging in the management of neuroendocrine tumors, adrenal tumors, pheochromocytomas and paragangliomas. From the collected data, the superiority of fused images was observed as providing both functional/molecular and morphological imaging compared to planar imaging. This provided an improvement in diagnostic imaging, with significant advantages as regards: (1) precise locating of the lesions; (2) an improvement in characterization of the findings, resulting higher specificity, improved sensitivity, and overall greater accuracy, (3) additional anatomical information derived from the CT component; (4) CT-based attenuation correction and potential for volumetric dosimetry calculations, and (5) improvement on the impact on patient management (e.g. in better defining treatment plans, in shortening surgical operating times). It can be concluded that SPECT/CT hybrid imaging provides the nuclear medicine physician with a powerful imaging modality in comparison to planar imaging, providing essential information about the location of lesions, and high quality homogeneous images. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  1. The current status of SPECT or SPECT/CT in South Korea

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Ik Dong; Choi, Eun Kyung; Chung, Yong An [Dept. of Radiology, Incheon Saint Mary' s HospitalThe Catholic University of Korea, Incheon (Korea, Republic of)

    2017-06-15

    The first step to nuclear medicine in Korea started with introduction of the gamma camera in 1969. Although planar images with the gamma camera give important functional information, they have the limitations that result from 2-dimensional images. Single-photon emission computed tomography (SPECT) due to its 3-dimensional image acquisition is superior to earlier planar gamma imaging in image resolution and diagnostic accuracy. As demand for a hybrid functional and anatomical imaging device has increased, integrated SPECT/CT systems have been used. In Korea, SPECT/CT was for the first time installed in 2003. SPECT/CT can eliminate many possible pitfalls on SPECT-alone images, making better attenuation correction and thereby improving image quality. Therefore, SPECT/CT is clinically preferred in many hospitals in various aspects. More recently, additional SPECT/CT images taken from the region with equivocal uptake on planar images have been helpful in making precise interpretation as part of their clinical workup in postoperative thyroid cancer patients. SPECT and SPECT/CT have various advantages, but its clinical application has gradually decreased in recent few years. While some researchers investigated the myocardial blood flow with cardiac PET using F-18 FDG or N-13 ammonia, myocardial perfusion SPECT is, at present, the radionuclide imaging study of choice for the risk stratification and guiding therapy in the coronary artery disease patients in Korea. New diagnostic radiopharmaceuticals for AD have received increasing attention; nevertheless, brain SPECT will remain the most reliable modality evaluating cerebral perfusion.

  2. Molecular imaging agents for SPECT (and SPECT/CT)

    International Nuclear Information System (INIS)

    Gnanasegaran, Gopinath; Ballinger, James R.

    2014-01-01

    The development of hybrid single photon emission computed tomography/computed tomography (SPECT/CT) cameras has increased the diagnostic value of many existing single photon radiopharmaceuticals. Precise anatomical localization of lesions greatly increases diagnostic confidence in bone imaging of the extremities, infection imaging, sentinel lymph node localization, and imaging in other areas. Accurate anatomical localization is particularly important prior to surgery, especially involving the parathyroid glands and sentinel lymph node procedures. SPECT/CT plays a role in characterization of lesions, particularly in bone scintigraphy and radioiodine imaging of metastatic thyroid cancer. In the development of novel tracers, SPECT/CT is particularly important in monitoring response to therapies that do not result in an early change in lesion size. Preclinical SPECT/CT devices, which actually have spatial resolution superior to PET/CT devices, have become essential in characterization of the biodistribution and tissue kinetics of novel tracers, allowing coregistration of serial studies within the same animals, which serves both to reduce biological variability and reduce the number of animals required. In conclusion, SPECT/CT increases the utility of existing radiopharmaceuticals and plays a pivotal role in the evaluation of novel tracers. (orig.)

  3. Molecular imaging agents for SPECT (and SPECT/CT)

    Energy Technology Data Exchange (ETDEWEB)

    Gnanasegaran, Gopinath [Guy' s and St Thomas' NHS Foundation Trust, Department of Nuclear Medicine, London (United Kingdom); Ballinger, James R. [Guy' s and St Thomas' NHS Foundation Trust, Department of Nuclear Medicine, London (United Kingdom); King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom)

    2014-05-15

    The development of hybrid single photon emission computed tomography/computed tomography (SPECT/CT) cameras has increased the diagnostic value of many existing single photon radiopharmaceuticals. Precise anatomical localization of lesions greatly increases diagnostic confidence in bone imaging of the extremities, infection imaging, sentinel lymph node localization, and imaging in other areas. Accurate anatomical localization is particularly important prior to surgery, especially involving the parathyroid glands and sentinel lymph node procedures. SPECT/CT plays a role in characterization of lesions, particularly in bone scintigraphy and radioiodine imaging of metastatic thyroid cancer. In the development of novel tracers, SPECT/CT is particularly important in monitoring response to therapies that do not result in an early change in lesion size. Preclinical SPECT/CT devices, which actually have spatial resolution superior to PET/CT devices, have become essential in characterization of the biodistribution and tissue kinetics of novel tracers, allowing coregistration of serial studies within the same animals, which serves both to reduce biological variability and reduce the number of animals required. In conclusion, SPECT/CT increases the utility of existing radiopharmaceuticals and plays a pivotal role in the evaluation of novel tracers. (orig.)

  4. Cardiac hybrid imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gaemperli, Oliver [University Hospital Zurich, Cardiac Imaging, Zurich (Switzerland); University Hospital Zurich, Nuclear Cardiology, Cardiovascular Center, Zurich (Switzerland); Kaufmann, Philipp A. [University Hospital Zurich, Cardiac Imaging, Zurich (Switzerland); Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland)

    2014-05-15

    Hybrid cardiac single photon emission computed tomography (SPECT)/CT imaging allows combined assessment of anatomical and functional aspects of cardiac disease. In coronary artery disease (CAD), hybrid SPECT/CT imaging allows detection of coronary artery stenosis and myocardial perfusion abnormalities. The clinical value of hybrid imaging has been documented in several subsets of patients. In selected groups of patients, hybrid imaging improves the diagnostic accuracy to detect CAD compared to the single imaging techniques. Additionally, this approach facilitates functional interrogation of coronary stenoses and guidance with regard to revascularization procedures. Moreover, the anatomical information obtained from CT coronary angiography or coronary artery calcium scores (CACS) adds prognostic information over perfusion data from SPECT. The use of cardiac hybrid imaging has been favoured by the dissemination of dedicated hybrid systems and the release of dedicated image fusion software, which allow simple patient throughput for hybrid SPECT/CT studies. Further technological improvements such as more efficient detector technology to allow for low-radiation protocols, ultra-fast image acquisition and improved low-noise image reconstruction algorithms will be instrumental to further promote hybrid SPECT/CT in research and clinical practice. (orig.)

  5. Usefulness of hybrid SPECT/CT for the {sup 99m}Tc-HMPAO-labeled leukocyte scintigraphy in a case of cranial osteomyelitis

    Energy Technology Data Exchange (ETDEWEB)

    Bruni, Chiara; Padovano, Federico; Travascio, Laura; Schillaci, Orazio; Simonetti, Giovanni [University of Rome Tor Vergata, Rome (Italy). Dept. of Diagnostic Imaging, Molecular Imaging, Interventional Radiology and Radiotherapy]. E-mail: chiarabruni79@hotmail.com

    2008-12-15

    Cranial osteomyelitis is a potentially fatal lesion. White blood cell scanning (WBC) with {sup 99m}Tc-hexamethylpropylene amine oxime (HMPAO) has proven highly sensitive and specific in the diagnosis and follow-up of patients with suspected osteomyelitis. In this report we show the usefulness of SPECT and transmission CT performed simultaneously using a hybrid imaging device for the functional anatomic mapping of soft tissue and cranial bone infections. {sup 99m}Tc-HMPAO-labeled leukocytes scintigraphy was performed on an elderly diabetic man with an intracranial mass lesion and with suspected temporal bone infection. Planar scans were acquired 30 min, 4 h, and 24 h after injection. SPECT/CT was obtained 6 h after tracer injection, using a dual-head camera coupled with a low-power X-ray tube. The scintigraphic results were matched with the results of surgery and of clinical follow-up. The planar images alone were true-positives for abscess in this patient. SPECT/CT improves the accuracy of {sup 99m}Tc- HMPAO scintigraphy especially in discriminating between soft-tissue and bone involvement. In fact, SPECT/CT also showed temporal bone osteomyelitis. This result indicates that SPECT/CT performed using a hybrid device can improve imaging with {sup 99m}Tc-HMPAO-labeled leukocytes in patients with suspected osteomyelitis by providing accurate anatomic localization and precise definition of the extent of infection. (author)

  6. First Robotic SPECT for Minimally Invasive Sentinel Lymph Node Mapping.

    Science.gov (United States)

    Fuerst, Bernhard; Sprung, Julian; Pinto, Francisco; Frisch, Benjamin; Wendler, Thomas; Simon, Hervé; Mengus, Laurent; van den Berg, Nynke S; van der Poel, Henk G; van Leeuwen, Fijs W B; Navab, Nassir

    2016-03-01

    In this paper we present the usage of a drop-in gamma probe for intra-operative Single-Photon Emission Computed Tomography (SPECT) imaging in the scope of minimally invasive robot-assisted interventions. The probe is designed to be inserted and reside inside the abdominal cavity during the intervention. It is grasped during the procedure using a robotic laparoscopic gripper enabling full six degrees of freedom handling by the surgeon. We demonstrate the first deployment of the tracked probe for intra-operative in-patient robotic SPECT enabling augmented-reality image guidance. The hybrid mechanical- and image-based in-patient probe tracking is shown to have an accuracy of 0.2 mm. The overall system performance is evaluated and tested with a phantom for gynecological sentinel lymph node interventions and compared to ground-truth data yielding a mean reconstruction accuracy of 0.67 mm.

  7. Sialoscintigraphy, dacryoscintigraphy, and 67Ga-scintigraphy in SJOGREN's syndrome

    International Nuclear Information System (INIS)

    De Rossi, G.

    1988-01-01

    In 68 cases of SJOGREN's syndrome (SS) dacryoscintigraphy (DS), sialoscintigraphy (SIS), and 67 Ga scintigraphy (GS) were performed along with other diagnostic examinations. Pre- and post-therapy results were available. The DS, SIS, and GS triad proves to be a simple, sensitive, and easy repeatable method to improve the diagnosis and follow-up of SS. (orig.) [de

  8. Evaluation of Edge Assembly Crossover for Hybrid GA

    OpenAIRE

    Yoshihara, Ikuo; Sato, Masakazu; Nguyen, Hung Dinh; Yamanori, Kunihito

    2004-01-01

    Abstract ###Traveling Salesman Problem (TSP) is one of the representative combinatorial optimization prob-###lems. The promising approach to solve TSP is Genetic Algorithm (GA). GA has global search ability, ###and heuristic is used in order to compensate local search ability, because GA is lack of local search abil-###ity. Hybrid (GA (HGA) combined with heuristics can be expected to obtain high quality solutions.We ###employ Lin-Kernighan heuristics which is very effective in TSP. Because cr...

  9. SFC Optimization for Aero Engine Based on Hybrid GA-SQP Method

    Science.gov (United States)

    Li, Jie; Fan, Ding; Sreeram, Victor

    2013-12-01

    This study focuses on on-line specific fuel consumption (SFC) optimization of aero engines. For solving this optimization problem, a nonlinear pneumatic and thermodynamics model of the aero engine is built and a hybrid optimization technique which is formed by combining the genetic algorithm (GA) and the sequential quadratic programming (SQP) is presented. The ability of standard GA and standard SQP in solving this type of problem is investigated. It has been found that, although the SQP is fast, very little SFC reductions can be obtained. The GA is able to solve the problem well but a lot of computational time is needed. The presented hybrid GA-SQP gives a good SFC optimization effect and saves 76.6% computational time when compared to the standard GA. It has been shown that the hybrid GA-SQP is a more effective and higher real-time method for SFC on-line optimization of the aero engine.

  10. In vivo evaluation of a radiogallium-labeled bifunctional radiopharmaceutical, Ga-DOTA-MN2, for hypoxic tumor imaging.

    Science.gov (United States)

    Sano, Kohei; Okada, Mayumi; Hisada, Hayato; Shimokawa, Kenta; Saji, Hideo; Maeda, Minoru; Mukai, Takahiro

    2013-01-01

    On the basis of the findings obtained by X-ray crystallography of Ga-DOTA chelates and the drug design concept of bifunctional radiopharmaceuticals, we previously designed and synthesized a radiogallium-labeled DOTA chelate containing two metronidazole moieties, (67)Ga-DOTA-MN2, for hypoxic tumor imaging. As expected, (67)Ga-DOTA-MN2 exhibited high in vivo stability, although two carboxyl groups in the DOTA skeleton were conjugated with metronidazole moieties. In this study, we evaluated (67/68)Ga-DOTA-MN2 as a nuclear imaging agent for hypoxic tumors. (67)Ga-labeling of DOTA-MN2 with (67)GaCl(3) was achieved with high radiochemical yield (>85%) by 1-min of microwave irradiation (50 W). The pharmacokinetics of (67)Ga-DOTA-MN2 were examined in FM3A tumor-bearing mice, and compared with those of (67)Ga-DOTA-MN1 containing one metronidazole unit and (67)Ga-DOTA. Upon administration, (67)Ga-DOTA-MN2 exhibited higher accumulation in the implanted tumors than (67)Ga-DOTA. Tumor-to-blood ratios of (67)Ga-DOTA-MN2 were about two-fold higher than those of (67)Ga-DOTA-MN1. Autoradiographic analysis showed the heterogeneous localization of (67)Ga-DOTA-MN2 in the tumors, which corresponds to hypoxic regions suggested by well-established hypoxia marker drug, pimonidazole. Furthermore, in positron emission tomography (PET) study, the tumors of mice administered (68)Ga-labeled DOTA-MN2 were clearly imaged by small-animal PET at 1 h after administration. This study demonstrates the potential usefulness of (67/68)Ga-DOTA-MN2 as a nuclear imaging agent for hypoxic tumors and suggests that two functional moieties, such as metronidazole, can be conjugated to radiogallium-DOTA chelate without reducing the complex stability. The present findings provide useful information about the chemical design of radiogallium-labeled radiopharmaceuticals for PET and single photon emission computed tomography (SPECT) studies.

  11. Clinical applications of SPECT/CT: advantages and limitations

    International Nuclear Information System (INIS)

    Rigo, P.

    2006-01-01

    The application of hybrid SPECT cameras in Nuclear Medicine follows the revolutionary introduction of PET/CT. This review focuses on the advantages and limitations of SPECT/CT in its various clinical indications. It appears that SPECT/CT will be a clear factor of progress for Nuclear Medicine. (author)

  12. 68Ga DOTA-TATE PET/CT allows tumor localization in patients with tumor-induced osteomalacia but negative 111In-octreotide SPECT/CT.

    Science.gov (United States)

    Breer, Stefan; Brunkhorst, Thomas; Beil, F Timo; Peldschus, Kersten; Heiland, Max; Klutmann, Susanne; Barvencik, Florian; Zustin, Jozef; Gratz, Klaus-Friedrich; Amling, Michael

    2014-07-01

    Tumor-induced osteomalacia (TIO) is a paraneoplastic syndrome characterized by renal phosphate wasting, hypophosphatemia and low calcitriol levels as well as clinical symptoms like diffuse bone and muscle pain, fatigue fractures or increased fracture risk. Conventional imaging methods, however, often fail to detect the small tumors. Lately, tumor localization clearly improved by somatostatin-receptor (SSTR) imaging, such as octreotide scintigraphy or octreotide SPECT/CT. However, recent studies revealed that still a large number of tumors remained undetected by octreotide imaging. Hence, studies focused on different SSTR imaging methods such as 68Ga DOTA-NOC, 68Ga DOTA-TOC and 68Ga DOTA-TATE PET/CT with promising first results. Studies comparing different SSTR imaging methods for tumor localization in TIO are rare and thus little is known about diagnostic alternatives once a particular method failed to detect a tumor in patients with TIO. Here, we report the data of 5 consecutive patients suffering from TIO, who underwent both 111Indium-octreotide scintigraphy (111In-OCT) SPECT/CT as well as 68Ga DOTA-TATE PET/CT for tumor detection. While 111In-OCT SPECT/CT allowed tumor detection in only 1 of 5 patients, 68Ga DOTA-TATE PET/CT was able to localize the tumor in all patients. Afterwards, anatomical imaging of the region of interest was performed with CT and MRI. Thus, successful surgical resection of the tumor was achieved in all patients. Serum phosphate levels returned to normal and all patients reported relief of symptoms within weeks. Moreover, an iliac crest biopsy was obtained from every patient and revealed marked osteomalacia in all cases. Follow-up DXA revealed an increase in BMD of up to 34.5% 1-year postoperative, indicating remineralization. No recurrence was observed. In conclusion our data indicates that 68Ga DOTA-TATE PET/CT is an effective and promising diagnostic tool in the diagnosis of TIO, even in patients in whom 111In-OCT prior failed to detect

  13. Comparative uptake of 67Ga and /sup 99m/Tc MDP in rabbits with a benign noninfected bone lesion (fracture)

    International Nuclear Information System (INIS)

    Bushberg, J.T.; Hoffer, P.B.; Schreiber, G.J.; Lawson, A.J.; Lawson, J.P.; Lord, P.

    1985-01-01

    Mid-shaft fractures of the radius and ulna were produced in 3 to 4 kg New Zealand white rabbits and quantitative uptake of /sup 99m/Tc MDP and 67 Ga determined at 11, 18, 25, 32, 51, and 78 days following fracture. Two hundred microCi of 67 Ga was administered 24 hours prior to sacrifice and 1.5 mCi /sup 99m/Tc MDP 2 hours prior to sacrifice. Specific activity ratios (SARs) were determined between fracture and control sides for bone, muscle and skin. SARs for bone were surprisingly similar for /sup 99m/Tc MDP and 67 Ga, reaching peak values of 6.07 +/- 0.64 (/sup 99m/Tc 18 days); 6.58 +/- 0.90 ( 67 Ga 32 days), subsequently decreasing to minimum values at 78 days postfracture (/sup 99m/Tc MDP 2.25 +/- 0.14; 67 Ga 2.18 +/- 0.08). There was no statistically significant difference in SAR for /sup 99m/Tc MDP vs. 67 Ga in bone at any time after fracture. Whole sections of limb were resected on selected animals and activity ratios determined for these sections as a function of the contribution of activity from the various tissues in the volume of interest. Total activity ratios of 67 Ga were lower than bone SARs as a result of the contribution of activity from muscle and skin. Thus, the apparent lower activity ratios noted on 67 Ga images compared with /sup 99m/Tc MDP images in this fracture model were not due to differences in bone SARs but rather due to the higher soft tissue background activity contribution in the 67 Ga images

  14. Labeling of monoclonal antibodies with a 67Ga-phenolic aminocarboxylic acid chelate. Part I. Chemistry and labeling technique.

    Science.gov (United States)

    Schuhmacher, J; Matys, R; Hauser, H; Maier-Borst, W; Matzku, S

    1986-01-01

    As a chelating agent for labeling antibodies (Abs) with metallic radionuclides, a propionic acid substituted ethylenediamine N,N'-di-[(o-hydroxyphenyl) acetic acid] (P-EDDHA), which tightly complexes 67Ga, was synthesized. The 67Ga-P-EDDHA chelate was coupled in aqueous solution to IgG at a molar ratio of 1:1 via carbodiimide. The average coupling yield was 15%. A specific activity of 4 mCi/mg IgG could be obtained with commercially supplied 67Ga. In vitro stability was evaluated in human serum at 37 degrees C and showed a half-life of about 120 h for the release of 67Ga from the labeled Ab during the initial phase of incubation. This in vitro halflife is similar to that measured for 111In-DTPA labeled Abs. Because of the high stability of the 67Ga-P-EDDHA chelate, the in vivo formation of radioactive labeled transferrin by transchelation, as described for 111In-DTPA labeled Abs, should, however, be reduced by this labeling technique.

  15. Labeling of antibodies with a /sup 67/Ga-phenolic aminocarboxylic acid chelate. Pt. 1. Chemistry and labeling technique

    Energy Technology Data Exchange (ETDEWEB)

    Schuhmacher, J.; Matys, R.; Hauser, H.; Maier-Borst, W.; Matzku, S.

    1986-11-01

    As a chelating agent for labeling antibodies (Abs) with metallic radionuclides, a propionic acid substituted ethylenediamine N, N'-di-((o-hydroxyphenyl) acetic acid) (P-EDDHA), which tighly complexes /sup 67/Ga, was synthetized. The /sup 67/Ga-P-EDDHA chelate was coupled in aqueous solution to IgG at a molar ratio of 1:1 via carbodiimide. The average coupling yield was 15%. A specific activity of 4 mCi/mg IgG could be obtained with commercially supplied /sup 67/Ga. In vitro stability was evaluated in human serum at 37/sup 0/C and showed a half-life of about 120 h for the release of /sup 67/Ga from the labeled Ab during the initial phase of incubation. This in vitro halflife is similar to that measured for /sup 111/In-DTPA labeled Abs. Because of the high stability of the /sup 67/Ga-P-EDDHA chelate, the in vivo formation of radioactive lebeled transferrin by transchelation, as described for /sup 111/In-DTPA labeled Abs, should, however, be reduced by this labeling technique.

  16. SPECT imaging in evaluating extent of malignant external otitis: case report

    International Nuclear Information System (INIS)

    English, R.J.; Tu'Meh, S.S.; Piwnica-Worms, D.; Holman, B.L.

    1987-01-01

    Otitis externa, a benign inflammatory process of the external auditory canal, is general responsive to local therapy. Some patients however, develop a less controllable disease leading to chondritis and osteomyelitis of the base of the skull. The direct invasive characteristic of the disease has led to the descriptive term malignant external otitis (MEO), more appropriately called necrotizing or invasive external otitis. Malignant external otitis is caused by an aggressive pseudomonas or proteus infection that almost exclusively occurs in elderly diabetic patients. The primary imaging modalities previously used in the diagnosis and evaluation of MEO were standard planar scintigraphic techniques with technetium-99M (/sup 99m/Tc) bone agents and gallium-67 ( 67 Ga), and pluridirectional tomography. The advent of high resolution computed tomography (CT) effectively allowed demonstration of the soft tissue extension and bone destruction associated with MEO, but still suffered from the low sensitivity constraints of all radiographic techniques in determining early inflammatory bone involvement. Recent work suggests that scintigraphic detection of MEO with /sup 99m/Tc-MDP and 67 Ga, combined with the cross-sectional resolution of single photon emission computed tomography (SPECT) may be of value in planning treatment of this inflammatory condition

  17. SPECT/spiral-CT hybrid imaging in unclear foci of increased bone metabolism: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Roemer, W.; Kuwert, T. [Nuklearmedizinische Klinik, Friedrich-Alexander-Univ. Erlangen/Nuernberg (Germany); Beckmann, M.W. [Frauenklinik, Friedrich-Alexander-Univ. Erlangen/Nuernberg (Germany); Forst, R. [Lehrstuhl fuer Orthopaedie mit Orthopaedischer Chirurgie, Friedrich-Alexander Univ. Erlangen/Nuernberg (Germany); Bautz, W. [Radiologisches Inst., Friedrich-Alexander-Univ. Erlangen/Nuernberg (Germany)

    2005-07-01

    In bone scintigraphy, the differentiation between degenerative processes and bone metastases is still difficult. Therefore, additional radiological studies are regularly needed after bone scintigraphy. The now introduced hybrid-cameras combining single-photon emission computed tomography (SPECT) and spiral-CT are unique in the sense that they offer the opportunity to correlate the functional information with morphology in one session. We herein present two patients in whom this technological setup allowed a definite diagnosis in scintigraphically unclear vertebral lesions. In a patient with breast cancer, hypermetabolic lesions were clearly correlated with osteolyses. In another patient with synovial carcinoma, spondylosis and spondylarthrosis caused focal tracer uptake in the lumbar spine. In addition to an improved diagnostic accuracy, SPECT/Spiral-CT will considerably abbreviate the diagnostic process. (orig.)

  18. SPECT/spiral-CT hybrid imaging in unclear foci of increased bone metabolism: a case report

    International Nuclear Information System (INIS)

    Roemer, W.; Kuwert, T.; Beckmann, M.W.; Forst, R.; Bautz, W.

    2005-01-01

    In bone scintigraphy, the differentiation between degenerative processes and bone metastases is still difficult. Therefore, additional radiological studies are regularly needed after bone scintigraphy. The now introduced hybrid-cameras combining single-photon emission computed tomography (SPECT) and spiral-CT are unique in the sense that they offer the opportunity to correlate the functional information with morphology in one session. We herein present two patients in whom this technological setup allowed a definite diagnosis in scintigraphically unclear vertebral lesions. In a patient with breast cancer, hypermetabolic lesions were clearly correlated with osteolyses. In another patient with synovial carcinoma, spondylosis and spondylarthrosis caused focal tracer uptake in the lumbar spine. In addition to an improved diagnostic accuracy, SPECT/Spiral-CT will considerably abbreviate the diagnostic process. (orig.)

  19. Augmented skeletal accumulation of Ga-67: a variant in children

    Energy Technology Data Exchange (ETDEWEB)

    Vakili, A; Puri, S; Spencer, R P [Connecticut Univ., Farmington (USA). Health Center

    1978-01-01

    Two case histories are reported in which 1 mCi of Ga-67 citrate was administered intravenously to one child with anaemia and hypothyroidism and another with promyelocytic leukemia. Intense osseous uptake was observed in both cases, without the usual pattern of activity in liver, bowel and internal organs.

  20. Ga-67 citrate myocardial uptake in a patient with AIDS, toxoplasmosis, and myocarditis

    International Nuclear Information System (INIS)

    Memel, D.S.; DeRogatis, A.J.; William, D.C.

    1991-01-01

    A 38-year-old man with AIDS presented with fever of unknown origin, splenomegaly, anemia, and thrombocytopenia. Admission laboratory data revealed a positive toxoplasmosis titer in the blood. The initial chest x-ray showed small bilateral pleural effusions, a normal cardiac silhouette, no infiltrates, and no interstitial edema. Ga-67 imaging revealed markedly abnormal uptake in the myocardium. A diagnosis of toxoplasmosis myocarditis was made based on laboratory and imaging data. The patient was treated for toxoplasmosis. No myocardial uptake of tracer was demonstrated on a follow-up Ga-67 scan, performed after completion of treatment for toxoplasmosis

  1. Prognostic impact of pre-transplantation computed tomography and 67gallium scanning in chemosensitive diffuse large B cell lymphoma patients undergoing hematopoietic stem-cell transplantation

    International Nuclear Information System (INIS)

    Escobar, Ignacio G.; Alonso, Pilar T.; Barrigon, Dolores C.; Perez-Simon, Jose A.; Mateos Manteca, Maria V.; San Miguel Izquierdo, Jesus F.

    2008-01-01

    In the present study, we evaluated computed tomography (CT) and 67 gallium scanning ( 67 Ga scan) pre-transplant as prognostic factors for overall survival (OS) and event-free survival (EFS) in patients with diffuse large B cell lymphoma, undergoing high-dose chemotherapy and stem-cell transplantation. Forty-two patients were included. Of these, 9 (21%) had both positive CT and 67 Ga scans, 17 (41%) negative results with both techniques, and 16 (38%) positive CT/negative 67 Ga scan. Whole-body planar imaging and single-photon emission computed tomography (SPECT) were performed 72 h after an intravenous administration of 67 Ga citrate measuring between 7 mCi and 10 mCi (259-370 MBq). Patients with positive CT/positive 67 Ga scan had a significantly worse EFS and OS at 5 years than those with negative 67 Ga scan regardless of whether it was associated with a positive or a negative CT scan (29% and 16% vs. 81% and 93% vs. 88% and 100%, respectively, P 67 Ga scan and those with positive CT/negative 67 Ga scan, with an EFS and OS at 5 years of 88% versus 81% and 100% versus 93%, respectively. In multivariate analysis, the presence of a pre-transplant positive CT/ 67 Ga scans adversely influenced both EFS and OS [HR 8, 95% confidence interval (CI) (1.4-38), P=0.03 and HR 2; 95% CI (1.3-8), P=0.02, respectively]. 67 Ga scan helps to identify, in the pre-transplant evaluation, two groups with a different outcome: one group of patients with positive CT and negative 67 Ga scans pre-transplant, who showed a favorable outcome with a low rate of relapse, and the other group of patients with both positive CT and 67 Ga scans pre-transplant, who showed a poor prognosis and did not benefit from autologous stem-cell transplantation. They should have been offered other therapeutic strategies. (author)

  2. Primary standardization of {sup 67}Ga radiopharmaceuticals

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, M.-C. [Health Physics Division, Institute of Nuclear Energy Research, No. 1000, Wunhua Road, Jiaan Village, Longtan Township, Taoyuan County 32546, Taiwan (China); Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu 300, Taiwan (China); Chen, I.-J. [Health Physics Division, Institute of Nuclear Energy Research, No. 1000, Wunhua Road, Jiaan Village, Longtan Township, Taoyuan County 32546, Taiwan (China); Wang, C.-F. [Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu 300, Taiwan (China)], E-mail: mcyuan@iner.gov.tw

    2008-06-15

    The two-dimensional extrapolation technique and dead time extrapolation technique of 4{pi}{beta}-{gamma}-coincidence counting were used to standardize the activity of {sup 67}Ga. The counting results of the two absolute counting techniques showed good agreement while the two-dimensional extrapolation technique could save about 50% of the total counting time in this study. The accuracy of the Capintec CRC-15R radionuclide calibrator used by the radiopharmacy of INER was studied in this research. A new calibration setting number, 99, was recommended to the radiopharmacy of INER in the Bayer 10 mL sterile empty vial geometry.

  3. Influence of the particle size of activated charcoal on labeling efficiency with 67Ga-citrate for colonic transit study

    International Nuclear Information System (INIS)

    Wan-Yu Lin; Shih-Chuan Tsai; Kai-Yuan Cheng; Bor-Tsung Hsieh

    2008-01-01

    Indium-111 and 99m Tc have been proposed for colonic transit study, but 111 In is expensive and the half-life of 99m Tc is too short for the study. Gallium-67 citrate is inexpensive and has a suitable half-life. In our previous study, we successfully labeled 67 Ga-citrate activated charcoal, and the labeling efficiency exceeded 91% after a 96 hour incubation period. In this work, we evaluated the influence of the size of activated charcoal particles on the labeling efficiency with 67 Ga-citrate. The data showed that the influence of particle size on the labeling efficiency of activated charcoal with 67 Ga was insignificant. Both sizes of activated charcoal particles can be used for labeling with 67 Ga in colonic transit study. (author)

  4. Scintigraphic evaluation of the liver in Fasciola hepatica with radiocolloid and 67Ga-citrate

    International Nuclear Information System (INIS)

    Aguirre Errasti, C.; Alberola Gomez-Escolar, I.; Gonzalez de Zarate, P.; Merino Angulo, J.

    1981-01-01

    A group of 23 patients with Fasciola hepatica have been studied in the province of Biscay. The diagnosis was reached after finding parasite eggs in the faeces or duodenal juice. The liver lesion was confirmed by means of macro and microscopic studies. Radiocolloid demonstrated the presence of cold areas in 18 patients; in 13 of them the uptake with 67 Ga was positive. These isotopic findings identified Fasciola hepatica as one of the causes of 'cold areas' in traditional liver scans and positive 67 Ga uptake. (orig.)

  5. The appearance of 'Lambda' and 'Panda' sign on Ga-67 scintigraphy in sarcoidosis

    International Nuclear Information System (INIS)

    Yoshimizu, Tazuko; Suga, Kazuyoshi; Orihashi, Norihiro; Soejima, Kyoko; Kaneko, Takafumi; Kawamura, Mitsutoshi; Nakanishi, Takashi; Utsumi, Hiromoto; Yamada, Norimasa

    1991-01-01

    The lesions of sarcoidosis generally show relatively high Ga-67 uptake and the usefulness of scintigraphy using this agent in the evaluation of lesion activity is well known. In this report, we assessed characteristic uptake of Ga-67 in intrathoracic lymph nodes, the shape of which resembled the Greek letter Lambda (Lambda sign) and a symmetrical accumulation in bilateral lacrimal and salivary glands which resembled a Panda face (Panda sign) in patients with sarcoidosis. Our review of Ga-67 scans obtained from 15 patients with sarcoidosis and 1,779 patients with other disorders during the past 3 years revealed that the simultaneous presence of both Lambda and Panda signs was specific to patients with sarcoidosis and was not found in patients with various other disorders, although one of these signs might be observed in patients without sarcoidosis. When Lambda-like sign was observed, chest radiogram or CT was necessary for the differential diagnosis of sarcoidosis. Panda sign was observed frequently among patients who had previously received irradiation of the neck. Our results confirmed that sarcoidosis must be suspected when both Lambda and Panda signs were observed. (author)

  6. Studies in rats on octreotide labelled with Ga-67: A potential radiopharmaceutical agent for the treatment of somatostatin receptor-positive tumours

    International Nuclear Information System (INIS)

    Lazniekova, A.; Laznieek, M.; Trejtnar, F.; Maecke, H.R.

    2001-01-01

    The paper presents the preparation, biodistribution and analysis of elimination mechanisms of 67 Ga-[DFO]-octreotide in rats. For labelling of the ligand with 67 Ga, desferrioxamine B (DFO) coupled to octreotide via the succinyl linker has been shown to form a stable chelating agent for binding of 67 Ga. The radiopharmaceutical was prepared by direct chelating of 67 Ga 3+ with [DFO]-octreotide in a slightly acidic reaction medium with high radiochemical purity. Pharmacokinetics of 67 Ga-[DFO]-octreotide of radioactivity in rats has shown relatively rapid elimination of the compound from the body with a long-term retention in the kidney and organs with high somatostatin receptor density. The agent was eliminated mostly by urine predominantly by the mechanism of glomerular filtration. (author)

  7. Enhancement of 67Ga tumor-to-blood ratios by chelating agent

    International Nuclear Information System (INIS)

    Saji, Hideo; Yokoyama, Akira; Hata, Naotaka; Misaki, Atsushi; Tanaka, Hisashi.

    1980-01-01

    Chelating agent, such as, CaEDTA, CaDTPA, D-penicillamine, DMSA, desferoxamine, NTA, cysteine ethyl ester, BAL, α-MPG, phthalein complexone, were tested as a possible contrast enhancing agent for tumor imaging with 67 Ga-citrate. The intravenous administration of a chelating agent to Ehrlich's tumor bearing mice, one hour after the injection of 67 Ga-citrate, accelerated the blood clearance with only a very slight change of activity in the target, increasing the tumor-to-blood ratio, and consequently achieving a better visualization. Among the tested chelating agents, D-penicillamine showed the highest target-to-nontarget ratio at a shorter time: a good tumor-to-blood ratio, performed after 24 hr with non-treated animals, was achieved in only 1-3 hr with post-treated animals. Thus, D-penicillamine hold a considerable promise as a contrast enhancing agent for future clinical use. (author)

  8. Lacrimal gland accumulation of 67Ga-citrate in patients with Sjoegren's syndrome

    International Nuclear Information System (INIS)

    Tanabe, M.; Tamai, T.; Satoh, K.; Kojima, K.; Hasegawa, E.; Matsuo, N.; Satoh, C.; Murakami, T.H.

    1984-01-01

    The extent of 67 Ga accumulation in the two lacrimal glands in patients with keratoconjunctivitis sicca (KCS) of Sjoegren's syndrome was studied. Of the two main groups one consisted of 69 subjects without ophthalmic complaints (control group), the other consisted of 26 patients with KCS of Sjoegren's syndome. Of the 26 patients with KCS, 7 has been diagnosed as probable KCS (probable sub-group) and the other 19 had been diagnosed definite KCS (definite sub-group). About 3 mCi (111 MBq) 67 Ga-citrate was injected IV into each subject and this was followed by scintigraphy at 24, 48, and 72 h after the injection of 67 Ga. A positive finding in the lacrimal gland was noted in 64 of 69 subjects (92.7%) in the control group and in 7 of 7 patients (100%) with probable KCS. Three of 19 patients with definite KCS (15.7%) showed positive findings under scintigraphy. When the scintigraphic finding in the lacrimal gland is not positive in patients with suspected KCS of Sjoegren's syndrome, they can then be diagnosed with little risk as definite KCS cases. Shirmer's test was performed on subjects in the probable and definite groups. There was statistical significance between the positive and equivocal or negative scintigraphic finding and Schirmer's values. These results suggest a correlation between gallium accumulation in the lacrimal gland and the tear production. (orig.)

  9. Hybrid device based on GaN nanoneedles and MEH-PPV/PEDOT:PSS polymer

    International Nuclear Information System (INIS)

    Shin, Min Jeong; Gwon, Dong-Oh; Lee, Chan-Mi; Lee, Gang Seok; Jeon, In-Jun; Ahn, Hyung Soo; Yi, Sam Nyung; Ha, Dong Han

    2015-01-01

    Highlights: • A hybrid device was demonstrated by using MEH-PPV, PEDOT:PSS, and GaN nanoneedles. • I–V curve of the hybrid device showed its rectification behaviour, similar to a diode. • EL peak originated by the different potential barriers at MEH-PPV and GaN interface. - Abstract: A hybrid device that combines the properties of organic and inorganic semiconductors was fabricated and studied. It incorporated poly[2-methoxy-5-(2-ethylhexyloxy)- 1,4-phenylenevinylene] (MEH-PPV) and poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) as organic polymers and GaN nanoneedles as an inorganic semiconductor. Layers of the two polymers were spin coated on to the GaN nanoneedles. The one peak in the electroluminescence spectrum originated from the MEH-PPV layer owing to the different potential barriers of electrons and holes at its interface with the GaN nanoneedles. However, the photoluminescence spectrum showed peaks due to both GaN nanoneedles and MEH-PPV. Such hybrid structures, suitably developed, might be able to improve the efficiency of optoelectronic devices

  10. Hybrid device based on GaN nanoneedles and MEH-PPV/PEDOT:PSS polymer

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Min Jeong; Gwon, Dong-Oh; Lee, Chan-Mi; Lee, Gang Seok [Department of Applied Science, Korea Maritime and Ocean University, Busan 606-791 (Korea, Republic of); Jeon, In-Jun [Department of Nano-semiconductor Engineering, Korea Maritime and Ocean University, Busan 606-791 (Korea, Republic of); Ahn, Hyung Soo [Department of Applied Science, Korea Maritime and Ocean University, Busan 606-791 (Korea, Republic of); Department of Nano-semiconductor Engineering, Korea Maritime and Ocean University, Busan 606-791 (Korea, Republic of); Yi, Sam Nyung, E-mail: snyi@kmou.ac.kr [Department of Applied Science, Korea Maritime and Ocean University, Busan 606-791 (Korea, Republic of); Department of Nano-semiconductor Engineering, Korea Maritime and Ocean University, Busan 606-791 (Korea, Republic of); Ha, Dong Han [Division of Convergence Technology, Korea Research Institute of Standards and Science, Daejeon 305-340 (Korea, Republic of)

    2015-08-15

    Highlights: • A hybrid device was demonstrated by using MEH-PPV, PEDOT:PSS, and GaN nanoneedles. • I–V curve of the hybrid device showed its rectification behaviour, similar to a diode. • EL peak originated by the different potential barriers at MEH-PPV and GaN interface. - Abstract: A hybrid device that combines the properties of organic and inorganic semiconductors was fabricated and studied. It incorporated poly[2-methoxy-5-(2-ethylhexyloxy)- 1,4-phenylenevinylene] (MEH-PPV) and poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) as organic polymers and GaN nanoneedles as an inorganic semiconductor. Layers of the two polymers were spin coated on to the GaN nanoneedles. The one peak in the electroluminescence spectrum originated from the MEH-PPV layer owing to the different potential barriers of electrons and holes at its interface with the GaN nanoneedles. However, the photoluminescence spectrum showed peaks due to both GaN nanoneedles and MEH-PPV. Such hybrid structures, suitably developed, might be able to improve the efficiency of optoelectronic devices.

  11. Clinical evaluation of scintigraphies with sup(99m)Tc-phytate and /sup 67/Ga-citrate as a screening test for hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Ayabe, Y; Oshiumi, Y; Kamoi, I; Ichiya, Y [Kyushu Univ., Fukuoka (Japan). Faculty of Medicine; Murakami, J

    1981-02-01

    sup(99m)Tc-phytate and /sup 67/Ga-citrate scintigraphies were evaluated clinically in 50 cases of histologically proven hepatocellular carcinoma. Detectability was higher in sup(99m)Tc-phytate scans than in /sup 67/Ga scans, and was influenced by the presence of liver cirrhosis. However, by using both scans, the highest detectability was obtained. /sup 67/Ga scan was useful especially in cases with equivocal sup(99m)Tc-phytate scintigraphy and cases with liver cirrhosis. There was no definite correlation seen between Edmondson's histological gradings and grades of /sup 67/Ga accumulation. No significant difference of /sup 67/Ga accumulation in hepatocellular carcinoma was observed regardless of the presence of liver cirrhosis. We conclude that it is better to use sup(99m)Tc-phytate as the first choice in screening of hepatocellular carcinoma and subsequent /sup 67/Ga scan if indicated.

  12. Hybrid SPECT/CT for the assessment of a painful hip after uncemented total hip arthroplasty

    International Nuclear Information System (INIS)

    Dobrindt, Oliver; Amthauer, Holger; Krueger, Alexander; Ruf, Juri; Wissel, Heiko; Grosser, Oliver S; Seidensticker, Max; Lohmann, Christoph H

    2015-01-01

    The diagnosis of hip pain after total hip replacement (THR) represents a highly challenging question that is of increasing concern to orthopedic surgeons. This retrospective study assesses bone scintigraphy with Hybrid SPECT/CT for the diagnosis of painful THR in a selected cohort of patients. Bone SPECT/CT datasets of 23 patients (mean age 68.9 years) with a painful hip after THR were evaluated. Selection of the patients required an inconclusive radiograph, normal serum levels of inflammatory parameters (CRP and ESR) or a negative aspiration of the hip joint prior to the examination. The standard of reference was established by an interdisciplinary adjudication-panel using all imaging data and clinical follow-up data (>12 month). Pathological and physiological uptake patterns were defined and applied. The cause of pain in this study group could be determined in 18 out of 23 cases. Reasons were aseptic loosening (n = 5), spine-related (n = 5), heterotopic ossification (n = 5), neuronal (n = 1), septic loosening (n = 1) and periprosthetic stress fracture (n = 1). In (n = 5) cases the cause of hip pain could not be identified. SPECT/CT imaging correctly identified the cause of pain in (n = 13) cases, in which the integrated CT-information led to the correct diagnosis in (n = 4) cases, mainly through superior anatomic correlation. Loosening was correctly assessed in all cases with a definite diagnosis. SPECT/CT of THA reliably detects or rules out loosening and provides valuable information about heterotopic ossifications. Furthermore differential diagnoses may be detected with a whole-body scan and mechanical or osseous failure is covered by CT-imaging. SPECT/CT holds great potential for imaging-based assessment of painful prostheses

  13. The Value of Attenuation Correction in Hybrid Cardiac SPECT/CT on Inferior Wall According to Body Mass Index

    International Nuclear Information System (INIS)

    Tamam, Muge; Mulazimoglu, Mehmet; Edis, Nurcan; Ozpacaci, Tevfik

    2016-01-01

    The purpose of this study was to evaluate the diagnostic value of attenuation-corrected single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) on the inferior wall compared to uncorrected (NC) SPECT MPI between obese and nonobese patients. A total of 157 consecutive patients (122 males and 35 females, with median age: 57.4 ± 11 years) who underwent AC technetium 99m-methoxyisobutylisonitrile (AC Tc99m-sestamibi) SPECT MPI were included to the study. A hybrid SPECT and transmission computed tomography (CT) system was used for the diagnosis with 1-day protocol, and stress imaging was performed first. During attenuation correction (AC) processing on a Xeleris Workstation using Myovation cardiac software with ordered subset expectation maximization (OSEM), iterative reconstruction with attenuation correction (IRAC) and NC images filtered back projection (FBP) were used. For statistical purposes, P < 0.05 was considered significant. This study included 73 patients with body mass index (BMI) <30 and 84 patients with BMI ≥ 30. In patients with higher BMI, increased amount of both visual and semiquantitative attenuation of the inferior wall was detected. IRAC reconstruction corrects the diaphragm attenuation of the inferior wall better than FBP. AC with OSEM iterative reconstruction significantly improves the diagnostic value of stress-only SPECT MPI in patients with normal weight and those who are obese, but the improvements are significantly greater in obese patients. Stress-only SPECT imaging with AC provides shorter and lower radiation exposure

  14. Clinical usefulness of subtraction scintigraphy of the liver with Ga-67-citrate and Tc-99m-colloid

    International Nuclear Information System (INIS)

    Oyamada, H.; Terui, S.; Nagaiwa, K.; Kawai, H.; Fukukita, H.

    1983-01-01

    Subtraction scintigraphy of the liver with Ga-67-citrate and Tc-99m-colloid was performed for the radionuclide image diagnosis of intrahepatic masses, especially hepatoma. In this method the Tc-99m image was subtracted from the Ga-67 image. After normalizing both images, 4 different factors (0.6, 0.8, 1.0, and 1.2) were applied to the Tc-99m image before the subtraction. Finally, 4 subtraction images with different contrasts were obtained in one X-ray film. This method was found to be very useful in the assessment of intrahepatic focal accumulation of Ga-67, especially in cases with hepatoma, because it eliminated the uncertainty in the former method in which only visual judgment was done

  15. Diagnostic performance and impact on patient management of 68Ga-DOTA-TOC PET/CT for detecting osteomalacia-associated tumours.

    Science.gov (United States)

    Paquet, Marie; Gauthé, Mathieu; Zhang Yin, Jules; Nataf, Valérie; Bélissant, Ophélie; Orcel, Philippe; Roux, Christian; Talbot, Jean-Noël; Montravers, Françoise

    2018-03-12

    Oncogenic osteomalacia is an endocrine disorder induced by small benign tumours (TIO) producing excessive fibroblast growth factor-23 (FGF23). The only way of curing oncogenic osteomalacia is surgical resection of the culprit TIO, which is extremely difficult to detect using conventional imaging modalities due to its small size and variable location in the body. Since TIO frequently overexpress somatostatin receptors, a clinical utility of SPECT or PET with radiolabelled somatostatin analogues has been reported. Among them, 68 Ga-DOTA-TOC has recently been granted a marketing authorization, facilitating its routine application. We report here the results of the first series evaluating the diagnostic performance of 68 Ga-DOTA-TOC PET/CT in detecting TIO and its impact on patient management. 68 Ga-DOTA-TOC PET/CT and clinical and imaging data from 15 patients with clinical and biochemical signs of oncogenic osteomalacia were retrospectively reviewed. The 68 Ga-DOTA-TOC PET/CT findings were compared with the results of post-surgical pathology and clinical and biochemical follow-up. 68 Ga-DOTA-TOC PET/CT resulted in the detection of one focus suspicious for TIO in nine of 15 patients (60%), and a tumour was surgically removed in eight. Post-operative pathology confirmed a TIO in those eight patients whose symptoms diminished promptly and biochemical anomalies resolved. 68 Ga-DOTA-TOC PET/CT sensitivity, specificity and accuracy were 73%, 67% and 71%, respectively. 68 Ga-DOTA-TOC PET/CT findings affected patient management in 67% of cases. In particular, 68 Ga-DOTA-TOC PET/CT was able to detect the TIO with a negative or a false-positive result of a previous 111 In-pentetreotide SPECT/CT in 5/8 patients (63%) or a previous FDG PET/CT in 7/11 patients (64%). No close relationship was found between the positivity of 68 Ga-DOTA-TOC PET/CT and the serum level of a biochemical marker. However, a true-positive result of 68 Ga-DOTA-TOC PET/CT was obtained in only one patient

  16. Scintigraphic evaluation of the liver in Fasciola hepatica with radiocolloid and /sup 67/Ga-citrate

    Energy Technology Data Exchange (ETDEWEB)

    Aguirre Errasti, C.; Alberola Gomez-Escolar, I.; Gonzalez de Zarate, P.; Merino Angulo, J.

    1981-02-01

    A group of 23 patients with Fasciola hepatica have been studied in the province of Biscay. The diagnosis was reached after finding parasite eggs in the faeces or duodenal juice. The liver lesion was confirmed by means of macro and microscopic studies. Radiocolloid demonstrated the presence of cold areas in 18 patients; in 13 of them the uptake with /sup 67/Ga was positive. These isotopic findings identified Fasciola hepatica as one of the causes of 'cold areas' in traditional liver scans and positive /sup 67/Ga uptake.

  17. Three phase bone scan , Ga-67 and Tc-99m nanocoll scan in detection of osteomyelitis caused by war injuries

    International Nuclear Information System (INIS)

    Banek, T.; Reljica-Kostic, Z.; Kurnik, G.

    1994-01-01

    Thirty three injured soldiers were surgically treated because of pierce wounds of extremities. Treatment was either osteosynthesis or external fixation. Two to four weeks post treatment clinical signs of osteomyelitis appeared. X-ray was negative in all patients. Three-phase bone scan was performed in order to establish diagnosis. Bone scan was positive in all patients. For 11 patients only bone scan was sufficient for decision of further treatment. In 22 patients Ga-67 or Tc-99m- nanocoll or both examinations were performed on surgeon's request. In 2 patients out of 5 with additional Ga-67 scan, Ga-67 scan showed more lesions than it was seen on bone scan. In 3 patients out of 5 with additional Tc-99m-nanocoll scan, Tc-99m-nanocoll scan showed more lesions than it was seen on bone scan. In 12 patients with positive bone scan and negative or unclear Ga-67, Tc-99m-nanocoll scan was performed. In 5 out of 12 patients Tc-99m- nanocoll scan established diagnosis in others confirmed finding on bone and Ga-67 scan. Our results showed that in one third of our causes bone scan was sufficient for diagnosing of osteomyelitis caused by war injuries. In selected cases where bone scan was not sufficient for diagnosis and decision for treatment Tc-99m-nanocoll was more sensitive than Ga-67. In our experience three-phase bone scan is more sensitive than Ga-67. In our opinion three-phase bone scan is the method of choice for diagnosing osteomyelitis in war situation with a lot of casualties. (author)

  18. Possibilities of the new hybrid technology single photon emission computer technology/computer tomography (SPECT/CT) and the first impressions of its application

    International Nuclear Information System (INIS)

    Kostadinova, I.

    2010-01-01

    With the help of the new hybrid technique SPECT/ CT it is possible, using the only investigation, to acquire a combine image of the investigated organ, visualizing its function and structure. Combining the possibilities of the new multimodality method, which combines the possibilities of the Single Photon Emission Computer Tomography - SPECT and Computer Tomography - CT, it is possible to precisely localize the pathologically changed organs function. With the further combination of the tomographic gamma camera with diagnostic CT, a detailed morphological evaluation of the finding was possible. The main clinical application of the new hybrid diagnostic is in the fields of cardiology, oncology, orthopedics with more and more extension of those, not connected with oncology, such as - thyroid, parathyroid, brain (especially localization of the epileptic foci), visualization of local infection and recently for the purposes of the radiotherapy planning. According to the literature data, around 35% of SPECT-investigations have to be combined with CT in order to increase the specificity of the diagnosis, which changes the interpretation of the result in 56% of the cases. After installation of the SPECT/CT camera in the University hospital 'Alexandrovska' in January 2009, the following changes have been done: the number of the investigated patients have increased, including number of heart, thyroid (especially scintigraphy with 131I), bones and parathyroid glands. As a result of the application of the hybrid technique, a shortage of the investigated time was realized and a decrease prize in comparison with the individual application of the investigations. Summarizing the literature data and the preliminary impression of the first multimodality scanner in our country in the University hospital 'Alexandrovska' it could be said, that there is continuously increasing information for the new clinical applications of SPECT/CT. It is now accepted, that its usage will increase in

  19. Effect of two tumors (metastatic and non-metastatic) on tissue distribution of Ga-67 citrate in the rat

    International Nuclear Information System (INIS)

    Durakovic, A.

    1985-01-01

    The effect of metastatic and non-metastatic mammary adenocarcinoma on tissue distribution of Ga-67 citrate in Fischer female rats was studied. The homogenate (0.1 ml) of each tumor was injected subcutaneously in separate groups of rats and the animals were studied from day 2-30 after tumor homogenate implantation. All animals were injected with 30 μCi of Ga-67 citrate and sacrificed by halothane anethesia 48 hours later. Tissue samples of blood, lung, heart, liver, spleen, kidney, adrenal, stomach, small and large intestine, ovaries, and lymph nodes (popliteal, lumbar, and mediastinal) were obtained and counted in a gamma well counter. The control group consisted of four animals and tumor bearing groups of seven to eight animals at each time. Ga-67 uptake was increased in the liver (24 days) and in the popliteal lymph nodes on days 7, 10, and 18 in the metastatic tumor group (P<0.05). This probably represents Ga-67 uptake in the metastatic deposits in these organs. No difference was observed in non-metastatic tumor group

  20. Production of 67Ga citrate injection liquid with butylacetate extraction method

    International Nuclear Information System (INIS)

    Fang Yibing; Li Bo; Liu Peng; Pan Qiyuan; Liu Peihua; Wang Han; Feng Jingling

    1995-01-01

    The distribution ratios D for Ga(III) at trace concentration in the HCl-butylacetate extraction system are measured. It showed that the D in 6 mol/l HCl is 5 x 10 2 which is maximum in 3-8 mol/l HCl. The extraction rates E in 5.5-8 mol/l HCl at phase ratio of 1 are ≥98% and ≥96% respectively when the concentration of ZnCl 2 in the solution are 0 and ≤2 mol/l. A butylacetate extraction method for the production of 67 Ga citrate injection liquid from Zn target irradiated by proton beam is developed. The optimal acidity of extraction is 6 mol/l HCl. The concentration of ZnCl 2 is adjusted to ≤2.0 mol/l and the impurity of Fe(III) in solution is reduced to Fe(II) with 10% TiCl 3 before extraction. The 67 Ga in organic phase is then stripped with water. The radionuclidic purity of the product is 100% while the radiochemical purity >90%. The amounts of Zn, Ti, Fe, Cu, Cd and Pb in the injection are below or near 1 mg/l. The test of abnormal toxicity is negative. The quality of the injection meets the requirements of both the Chinese and the United States Pharmacopoeia. The chemical yield is (92 +- 2)% while the time of operation is <3 h

  1. Preparation of Ga-67 labeled monoclonal antibodies using deferoxamine as a bifunctional chelating agent

    International Nuclear Information System (INIS)

    Endo, K.; Furukawa, T.; Ohmomo, Y.

    1984-01-01

    Ga-67 labeled monoclonal IgG or F(ab')/sub 2/ fragments against α-fetoprotein and β-subunit of human choriogonadotropin (HCG), were prepared using Deferoxamine (DFO) as a bifunctional chelating agent. DFO, a well-known iron chelating agent, was conjugated with monoclonal antibodies (Ab) by a glutaraldehyde two step method and the effect of conjugation on the Ab activities was examined by RIA and Scatchard plot analysis. In both monoclonal Ab preparations, the conjugation reaction was favored as the pH increased. However, Ab-binding activities decreased as the molecular ratios of DFO to Ab increased. Preserved Ab activities were observed when Ab contained DFO per Ab molecule less than 2.1. At a ratio of over 3.3 DFO molecules per Ab, the maximal binding capacity rather than the affinity constant decreased. The inter-molecular cross linkage seemed to be responsible for the deactivation of binding activities. The obtained DFO-Ab conjugates, were then easily labeled with high efficiency and reproducibility and Ga-67 DFO-Ab complexes were highly stable both in vitro and in vivo. Thus, biodistribution of Ga-67 labeled F(ab')/sub 2/ fragments of monoclonal Ab to HCG β-subunit was attempted in nude mice transplanted with HCG-producing human teratocarcinoma. Tumor could be visualized, in spite of relatively high background imaging of liver, kidney and spleen. The use of DFO as a bifunctional chelating agent provided good evidence for its applicability to labeling monoclonal Ab with almost full retention of Ab activities. Further, availability of Ga-68 will make Ga-68 DFO-monoclonal Ab a very useful tool for positron tomography imaging of various tumors

  2. Exciton emission from bare and hybrid plasmonic GaN nanorods

    Science.gov (United States)

    Mohammadi, Fatemesadat; Kunert, Gerd; Hommel, Detlef; Ge, Jingxuan; Duscher, Gerd; Schmitzer, Heidrun; Wagner, Hans Peter

    We study the exciton emission of hybrid gold nanoparticle/Alq3 (aluminiumquinoline)/wurtzite GaN nanorods. GaN nanorods of 1.5 μm length and 250 nm diameter were grown by plasma assisted MBE. Hybrid GaN nanorods were synthesized by organic molecular beam deposition. Temperature and power dependent time integrated (TI) and time resolved (TR) photoluminescence (PL) measurements were performed on bare and hybrid structures. Bare nanorods show donor (D0,X) and acceptor bound (A0,X) exciton emission at 3.473 eV and at 3.463 eV, respectively. TR-PL trace modeling reveal lifetimes of 240 ps and 1.4 ns for the (D0,X) and (A0,X) transition. 10 nm gold coated GaN nanorods show a significant PL quenching and (D0,X) lifetime shortening which is tentatively attributed to impact ionization of (D0,X) due to hot electron injection from the gold nanoparticles. This is supported by electron energy loss spectroscopy that shows a redshift of a midgap state transition indicating a reduction of a preexisting band-bending at the nanorod surface due to positive charging of the gold nanoparticles. Inserting a nominally 5 nm thick Alq3 spacer between the nanorod and the gold reduces the PL quenching and lifetime shortening. Plasmonic nanorods with a 30 nm thick Alq3 spacer reveal lifetimes which are nearly identical to uncoated GaN nanorods.

  3. Workflow Scheduling Using Hybrid GA-PSO Algorithm in Cloud Computing

    Directory of Open Access Journals (Sweden)

    Ahmad M. Manasrah

    2018-01-01

    Full Text Available Cloud computing environment provides several on-demand services and resource sharing for clients. Business processes are managed using the workflow technology over the cloud, which represents one of the challenges in using the resources in an efficient manner due to the dependencies between the tasks. In this paper, a Hybrid GA-PSO algorithm is proposed to allocate tasks to the resources efficiently. The Hybrid GA-PSO algorithm aims to reduce the makespan and the cost and balance the load of the dependent tasks over the heterogonous resources in cloud computing environments. The experiment results show that the GA-PSO algorithm decreases the total execution time of the workflow tasks, in comparison with GA, PSO, HSGA, WSGA, and MTCT algorithms. Furthermore, it reduces the execution cost. In addition, it improves the load balancing of the workflow application over the available resources. Finally, the obtained results also proved that the proposed algorithm converges to optimal solutions faster and with higher quality compared to other algorithms.

  4. The impact of different imaging modalities of 67Ga scintigraphy on the image quality and the ability in detection of lesions

    International Nuclear Information System (INIS)

    Liu Xiuqin; Li Wenchan; Zhang Jianfei; Yao Zhiming

    2009-01-01

    Objective: 67 Ga scintigraphy is an important method in detection of active sarcoidosis. The aim of this research was to study the influence of planar and tomography. with and without CT attenuation correction (AC and NAC), on 67 Ga images on the image quality and the ability in detection of lesions. Methods: Thirty one patients (13 male, 18 female, age range: 33-87 years)with sarcoidosis underwent 67 Ga planar and tomographic scans. AC and NAC.The imaging quality and the ability in detection of hyper-radioactive lymph nodes in lung hilar and mediastinal(1esion) among the planar, AC and NAC images were compared. The paired t-test and χ 2 -test were used for data analysis with SPSS 10.0 software. Results: From planar, NAC to AC, the image quality was better and better in proper order (χ 2 = 25.88, P 67 Ga tomographic scintigraphy can impmve the ability in detection of hyperradioactive lung hilar and mediastinal lymph nodes compared with planar image does. CT AC for 67 Ga tomography can improve the tomographic imaging quality. (authors)

  5. SPECT/CT workflow and imaging protocols

    Energy Technology Data Exchange (ETDEWEB)

    Beckers, Catherine [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Hustinx, Roland [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Domaine Universitaire du Sart Tilman, Service de Medecine Nucleaire et Imagerie Oncologique, CHU de Liege, Liege (Belgium)

    2014-05-15

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  6. SPECT/CT workflow and imaging protocols

    International Nuclear Information System (INIS)

    Beckers, Catherine; Hustinx, Roland

    2014-01-01

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  7. SPECT/CT and pulmonary embolism

    Energy Technology Data Exchange (ETDEWEB)

    Mortensen, Jann [Copenhagen University Hospital, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); The Faroese National Hospital, Department of Medicine, Torshavn (Faroe Islands); Gutte, Henrik [Copenhagen University Hospital, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); Herlev Hospital, Copenhagen University Hospital, Department of Radiology, Copenhagen (Denmark); University of Copenhagen, Cluster for Molecular Imaging, Faculty of Health Sciences, Copenhagen (Denmark)

    2014-05-15

    Acute pulmonary embolism (PE) is diagnosed either by ventilation/perfusion (V/P) scintigraphy or pulmonary CT angiography (CTPA). In recent years both techniques have improved. Many nuclear medicine centres have adopted the single photon emission CT (SPECT) technique as opposed to the planar technique for diagnosing PE. SPECT has been shown to have fewer indeterminate results and a higher diagnostic value. The latest improvement is the combination of a low-dose CT scan with a V/P SPECT scan in a hybrid tomograph. In a study comparing CTPA, planar scintigraphy and SPECT alone, SPECT/CT had the best diagnostic accuracy for PE. In addition, recent developments in the CTPA technique have made it possible to image the pulmonary arteries of the lungs in one breath-hold. This development is based on the change from a single-detector to multidetector CT technology with an increase in volume coverage per rotation and faster rotation. Furthermore, the dual energy CT technique is a promising modality that can provide functional imaging in combination with anatomical information. Newer high-end CT scanners and SPECT systems are able to visualize smaller subsegmental emboli. However, consensus is lacking regarding the clinical impact and treatment. In the present review, SPECT and SPECT in combination with low-dose CT, CTPA and dual energy CT are discussed in the context of diagnosing PE. (orig.)

  8. Determination of radiation loads from examination of the colon by 67Ga citrate

    International Nuclear Information System (INIS)

    Mihalova, P.; Buncova, M.; Vrba, T.

    2011-01-01

    This paper deals with the determination of radiation loads from examination of the colon by gallium citrate. The average calculated committed effective dose after administration of 5 MBq of 67 Ga-citrate is 2.05 mSv.

  9. Hybrid imaging (SPECT/CT, PET/CT) in differentiated thyroid cancer; Imagerie hybride (TEMP/TDM, TEP/TDM) et cancer differencie de la thyroide

    Energy Technology Data Exchange (ETDEWEB)

    Bardet, S.; Ciappuccini, R.; Aide, N. [Unite de concertation pluridisciplinaire thyroide, service de medecine nucleaire, centre Francois-Baclesse, 14 - Caen (France); Barraux, V. [Unite de radiophysique, centre Francois-Baclesse, 14 - Caen (France); Rame, J.P. [Chirurgie ORL, centre Francois-Baclesse, 14 - Caen (France)

    2010-08-15

    Differentiated thyroid cancer (DTC) is generally associated with a good prognosis. Local recurrences, mainly lymph-node involvement, account for 15-20% of cases and are surgically treated. Distant metastases, mostly in lungs and more rarely in bones, are present in 5% of patients. When iodine uptake is sufficient (in approximately 60% of patients), distant metastases can be destroyed by iterative activities of iodine 131. Serum thyroglobulin (Tg), which can be assessed either on hormonal treatment or on TSH stimulation is considered as the tumour marker in DTC. Functional (iodine 131 scintigraphy, FDG PET, bone scintigraphy) or anatomical (neck ultrasound, thoracic CT, bone MRI) imaging methods can be performed when Tg increases in order to show residual/recurrent disease. In recent years, new hybrid equipments integrating both a gamma camera and CT scan (SPECT/CT) have been commercialized while positron emission tomography cameras associated with CT (PET/CT) have been installed on the whole French territory. These equipments, which allow us to directly correlate functional and anatomical images, greatly improve the interpretation of planar scintigraphy or that of PET alone. Hybrid imaging enables us to precisely localize scintigraphic foci and most often, to immediately verify whether they correspond to tumour lesions. The aim of this article is to review the role of SPECT/CT and PET/CT in the management of patients with DTC in 2010. (authors)

  10. Mechanism of /sup 67/Ga uptake by an experimental abscess. Permeability of plasma from blood vessel in abscess

    Energy Technology Data Exchange (ETDEWEB)

    Nitta, Kazuo; Ogawa, Hiroshi; Ando, Atsushi; Ando, Itsuko; Hiraki, Tatsunosuke; Hisada, Kinichi

    1985-06-01

    In the previous paper, we reported that /sup 67/Ga was accumulated in abscess and uptake rate of /sup 67/Ga in abscess increased with time after the injection of /sup 67/Ga-citrate. The present study was undertaken to elucidate the influence of blood flow on the accumulation of /sup 67/Ga in abscess. Five days after subcutaneous injection of 0.2 ml of turpentine to the rats, /sup 131/I-human serum albumin (HSA) was injected intravenously to the rats. At an appropriate time after the injection (10 min to 6 days), uptake rates of /sup 131/I-HSA in abscess and normal tissues were measured. Similarly, /sup 51/Cr-red blood cells (RBC) were injected intravenously to the above rats and the uptake rates of /sup 51/Cr-RBC were also measured. One, three, and 24 hours after injection of /sup 131/I-HSA, the uptake rates of /sup 131/I-HSA in abscess were 1.32 %dose/g, 1.84 %dose/g, and 0.82 %dose/g, respectively. However, the uptake rates of /sup 51/Cr-RBC in abscess was very small, and the value was 0.14 %dose/g at 24 hours after the injection. In the case of abscess, blood in the tissue fluid was very little, but the permeability of /sup 131/I-HSA from the blood vessel in the tissue was much larger than that of normal tissues. From these facts, it was deduced that the accelerated permeability caused the abscess accumulation of /sup 67/Ga.

  11. Efficiency enhancement of InGaN/GaN multiple quantum wells with graphene layer

    International Nuclear Information System (INIS)

    Deng, Zhen; Li, Zishen; Jiang, Yang; Ma, Ziguang; Fang, Yutao; Li, Yangfeng; Wang, Wenxin; Jia, Haiqiang; Chen, Hong

    2015-01-01

    In this work, a novel hybrid graphene/InGaN-based multiple quantum wells (MQWs) structure has been fabricated. Compared to the sample conventional structure (CS), the utilization of graphene transferred on top GaN layer significantly enhances the internal quantum efficiency and relatively photoluminescence intensity. Furthermore, the excitons in the MQWs of sample hybrid structure (HS) have a shorter decay lifetime of 3.4 ns than that of 6.7 ns for sample CS. These results are probably attributed to the free carriers in the graphene layer, which can screen the piezoelectric field in the active region and thus present a free quantum-confined Stark effect-like behavior. Our work demonstrates that the graphene on the top GaN layer can effectively increase the recombination rate in sample HS, which may further improve LEDs' performance. (orig.)

  12. Comparison of the 68Ga-DOTATATA PET/CT, FDG PET/CT, and MIBG SPECT/CT in the Evaluation of Suspected Primary Pheochromocytomas and Paragangliomas.

    Science.gov (United States)

    Jing, Hongli; Li, Fang; Wang, Ling; Wang, Zhenghua; Li, Wei; Huo, Li; Zhang, Jingjing

    2017-07-01

    Anatomical imaging modalities including CT and MRI are the mainstay of evaluation of primary pheochromocytoma or paraganglioma. However, nuclear medicine imaging is frequently necessary to determine the nature of the lesions. The purpose of this investigation is to assess which commonly used nuclear medicine modality might have a better diagnostic value in this clinical setting. Eight patients who had been suspected of having either primary pheochromocytoma or primary paraganglioma and 1 patient with known pheochromocytoma were included in the analysis. Among the 8 patients without known diagnosis, 7 had been suggested by anatomical imaging modalities, whereas one of them presented with initial negative anatomical imaging interpretation. All of 9 patients underwent Ga-DOTATATA PET/CT, FDG PET/CT, and MIBG SPECT/CT for further evaluation. The imaging findings were compared with postsurgical pathology and follow-up. Both Ga-DOTATATA PET/CT and MIBG SPECT/CT accurately identified 9 primary tumors, whereas FDG PET/CT showed increased activity in 8 of 9 primary tumors. Both Ga-DOTATATA and FDG PET/CT are able to detect associated extra-adrenal lesions not shown on MIBG study in patients with multiple endocrine neoplasia syndrome. Ga-DOTATATA PET/CT could be the nuclear medicine imaging choice to evaluate suspected primary pheochromocytoma or paraganglioma, especially in the situation of multiple endocrine neoplasia syndrome.

  13. Roles of 67Ga-scintigraphy and CT in the decision of surgical treatment in cases with suspected abdominal abscess

    International Nuclear Information System (INIS)

    Kuwabara, Yasuo; Yasumori, Kotaro; Oshiumi, Yoshihiko; Nishitani, Hiromu; Ichiya, Yuichi

    1983-01-01

    67 Ga-scintigraphy and computed tomography in the decision of surgical treatment of abdominal abscess were evaluated in 37 clinically suspected cases. Eight of them were treated surgically. In the remaining 29 cases, 24 were treated conservatively, and 5 were confirmed not having abscesses at surgery for some other reason or autopsy. The clinical decisions in this study were considered to be appropriate, because there was no fatal case directly related to the existence of abscess. The sensitivity of 67 Ga-scintigraphy for surgically treated abscess was 88% (7/8), that of computed tomography was 100% (8/8). The specificity of 67 Ga-scintigraphy was 45% (13/29), that of computed tomography was 62% (18/29). In cases with descrepancy between 67 Ga-scintigraphy and computed tomography, computed tomography was more specific for abscess. It is concluded that in cases with negative findings in either examination, it is possible to deny a presence of abscess requring surgical treatment. However, even in cases with positive findings in both examinations, surgical treatment should be decided finally including other clinical informations. (author)

  14. Ventilation/perfusion SPECT or SPECT/CT for lung function imaging in patients with pulmonary emphysema?

    Science.gov (United States)

    Froeling, Vera; Heimann, Uwe; Huebner, Ralf-Harto; Kroencke, Thomas J; Maurer, Martin H; Doellinger, Felix; Geisel, Dominik; Hamm, Bernd; Brenner, Winfried; Schreiter, Nils F

    2015-07-01

    To evaluate the utility of attenuation correction (AC) of V/P SPECT images for patients with pulmonary emphysema. Twenty-one patients (mean age 67.6 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. AC/non-AC V/P SPECT images were compared visually and semiquantitatively. Visual comparison of AC/non-AC images was based on a 5-point likert scale. Semiquantitative comparison assessed absolute counts per lung (aCpLu) and lung lobe (aCpLo) for AC/non-AC images using software-based analysis; percentage counts (PC = (aCpLo/aCpLu) × 100) were calculated. Correlation between AC/non-AC V/P SPECT images was analyzed using Spearman's rho correlation coefficient; differences were tested for significance with the Wilcoxon rank sum test. Visual analysis revealed high conformity for AC and non-AC V/P SPECT images. Semiquantitative analysis of PC in AC/non-AC images had an excellent correlation and showed no significant differences in perfusion (ρ = 0.986) or ventilation (ρ = 0.979, p = 0.809) SPECT/CT images. AC of V/P SPECT images for lung lobe-based function imaging in patients with pulmonary emphysema do not improve visual or semiquantitative image analysis.

  15. Prospective Evaluation of (99m)Tc-sestamibi SPECT/CT for the Diagnosis of Renal Oncocytomas and Hybrid Oncocytic/Chromophobe Tumors.

    Science.gov (United States)

    Gorin, Michael A; Rowe, Steven P; Baras, Alexander S; Solnes, Lilja B; Ball, Mark W; Pierorazio, Phillip M; Pavlovich, Christian P; Epstein, Jonathan I; Javadi, Mehrbod S; Allaf, Mohamad E

    2016-03-01

    Nuclear imaging offers a potential noninvasive means of determining the histology of renal tumors. The aim of this study was to evaluate the accuracy of technetium-99m ((99m)Tc)-sestamibi single-photon emission computed tomography/x-ray computed tomography (SPECT/CT) for the differentiation of oncocytomas and hybrid oncocytic/chromophobe tumors (HOCTs) from other renal tumor histologies. In total, 50 patients with a solid clinical T1 renal mass were imaged with (99m)Tc-sestamibi SPECT/CT prior to surgical resection. Preoperative SPECT/CT scans were reviewed by two blinded readers, and their results were compared with centrally reviewed surgical pathology data. Following surgery, 6 (12%) tumors were classified as renal oncocytomas and 2 (4%) as HOCTs. With the exception of 1 (2%) angiomyolipoma, all other tumors were renal cell carcinomas (82%). (99m)Tc-sestamibi SPECT/CT correctly identified 5 of 6 (83.3%) oncocytomas and 2 of 2 (100%) HOCTs, resulting in an overall sensitivity of 87.5% (95% confidence interval [CI], 47.4-99.7%). Only two tumors were falsely positive on SPECT/CT, resulting in a specificity of 95.2% (95% CI, 83.8-99.4%). In summary, (99m)Tc-sestamibi SPECT/CT is a promising imaging test for the noninvasive diagnosis of renal oncocytomas and HOCTs. We found that the imaging test (99m)Tc-sestamibi SPECT/CT can be used to accurately diagnose two types of benign kidney tumors. This test may be eventually used to help better evaluate patients diagnosed with a renal tumor. Copyright © 2015 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  16. Diagnostic impact of SPECT-CT in the assessment of endocrine tumors

    International Nuclear Information System (INIS)

    El Badaoui, A.; Clermont, H. de; Valli, N.; Caignon, J.M.; Fernandez, P.; Allard, M.; Barat, J.L.; Ducassou, D.; Clermont, H. de; Valli, N.; Caignon, J.M.; Fernandez, P.; Allard, M.; Barat, J.L.; Ducassou, D.; Clermont, H. de; Allard, M.

    2008-01-01

    Image fusion using single photon emission computed tomography - computed tomography (SPECT - CT) associates functional and morphological images. This study evaluates the added value of SPECT- CT, obtained with a hybrid SPECT- CT gamma camera, on anatomic localization and diagnostic impact in assessment of endocrine tumours and pheochromocytomas. Method: Six months prospective study was undertaken including 33 consecutive exams encompassing 20 Somatostatin Receptor Scintigraphies (S.R.S.) and 13 123 I-meta-iodo-benzyl-guanidine (Mibg) scans. Two experienced nuclear medicine physicians independently analysed independently planar and SPECT images in a first time, then, SPECT- CT fused images in a second time. They evaluated two parameters: SPECT- CT impact on anatomic localization (L.A.) and its diagnostic impact (I.D.). Each parameter was scored according three levels of evaluation. Results: An added value of SPECT- CT images was evidenced in 55% of cases on the anatomic localization and in 41% of the patients on the diagnostic impact. Therefore, a more important benefit was noted when SPECT was positive (L.A.: 90%; I.D.: 70%) than when it was negative (L.A.: 15%; I.D.: 8%). Furthermore, the added value proved higher for the S;R.S. compared to Mibg scans. Conclusion: SPECT- CT fusion images obtained by a hybrid system is more relevant to determine anatomic localization and more accurate than SPECT alone, particularly in the assessment of endocrine tumours. The added value of SPECT- CT seems to be lower for Mibg scans in the assessment of pheochromocytomas. (authors)

  17. Development of methods for the purification of 67Ga and 68Ga for biomolecules labeling

    International Nuclear Information System (INIS)

    Costa, Renata Ferreira

    2012-01-01

    For more than fifty years, the long-lived 68 Ge/ 68 Ga generators have been in development, obtaining 68 Ga without the need of having in house cyclotron, which is a considerable convenience for PET centers that have no nearby cyclotrons. 68 Ga decays 89% by positron emission and low photon emission (1077 keV) and the physical half life of 67.7 minutes is compatible with the pharmacokinetics of low biomolecular weight substances like peptides and antibody fragments. Moreover, its established metallic chemistry allows it to be stably bound to the carrier peptide sequence via a suitable bifunctional chelator, such as DOTA. All these reasons together with the technology of PET/CT allowed advances in molecular imaging, in particular in the diagnosis of neuroendocrine diseases. However, the eluate from the commercial 68 Ge/ 68 Ga generators still contains high levels of long lived 68 Ge, besides other metallic impurities, which competes with 68 Ga with a consequent reduction of the labeling yield of biomolecules, such as Fe 3+ and Zn 2+ . Thus, the lower the amount of impurities in the eluate, the competition between the radiolabeled and unlabeled peptide by the receptor will be smaller and the quality of imaging will be better, a subsequent purification step is needed after the generator elution. The aim of this work is to evaluate different purifications methods of 68 Ga to label biomolecules, with emphasis on the study of the chemical impurities contained in the eluate and to develop a new purification method. Several purification methods were studied. Many cationic resin were tested simulating the commercial process. 68 Ga is adsorbed in cationic resin, which is not commercial available and eluted in acid/acetone solution. The use of minor particles of cationic resin AG50W-X4 (200-400 mesh) showed the best results. An innovate method was the extraction chromatography, which is based on the absorption of diisopropyl ether in XAD 16 and 68 Ga recovery in deionized

  18. Clinical applications of SPECT-CT

    Energy Technology Data Exchange (ETDEWEB)

    Ahmadzadehfar, Hojjat; Biersack, Hans-Juergen (eds.) [University Hospital Bonn (Germany). Dept. of Nuclear Medicine

    2014-06-01

    Covers the full spectrum of clinical applications of SPECT/CT in diagnosis of benign and malignant diseases. Includes chapters on the use of SPECT/CT for dosimetry and for therapy planning. Completely up to date. Many helpful illustrations. SPECT/CT cameras have considerably improved diagnostic accuracy in recent years. Such cameras allow direct correlation of anatomic and functional information, resulting in better localization and definition of scintigraphic findings. In addition to this anatomic referencing, CT coregistration provides superior quantification of radiotracer uptake based on the attenuation correction capabilities of CT. Useful applications of SPECT/CT have been identified not only in oncology but also in other specialties such as orthopedics and cardiology. This book covers the full spectrum of clinical applications of SPECT/CT in diagnosis and therapy planning of benign and malignant diseases. Opening chapters discuss the technology and physics of SPECT/CT and its use for dosimetry. The role of SPECT/CT in the imaging of a range of pathologic conditions is then addressed in detail. Applications covered include, among others, imaging of the thyroid, bone, and lungs, imaging of neuroendocrine tumors, cardiac scintigraphy, and sentinel node scintigraphy. Individual chapters are also devoted to therapy planning in selective internal radiation therapy of liver tumors and bremsstrahlung SPECT/CT. Readers will find this book to be an essential and up-to-date source of information on this invaluable hybrid imaging technique.

  19. Value of 67Ga scintigraphy in primary diagnosis and follow-up of opportunistic pneumonias in patients with AIDS

    International Nuclear Information System (INIS)

    Tatsch, K.; Knesewitsch, P.; Kirsch, C.M.; Kueffer, G.; Doerner, G.; Moser, E.; Matuschke, A.; Bogner, J.; Goebel, F.D.

    1988-01-01

    Opportunistic pneumonias are a life-threatening complication in patients with AIDS. Early diagnosis and therapy is necessary to improve prognosis. This study was designed to assess the value of 67 Ga scintigraphy in the primary detection and follow-up of these special pneumonias. 67 Ga scintigraphy was performed in 40 patients: 10 normal controls and 30 HIV-positive patients with AIDS or AIDS-related complex (ARC). 67 Ga scan results were compared with current chest radiographs and the results of pathogen detection. The evaluation of positive scans was based on a quantification of the pulmonary uptake, expressed as a pulmonary/soft-tissue uptake ratio. Only 8/30 patients had a normal scan, 22/30 showed diffuse (13/22) or focal (9/22) increases of pulmonary uptake. In 7/8 patients with normal scans the chest radiograph was negative as well. The one patient with negative scan but positive chest radiograph had pulmonary Kaposi's sarcoma. In 11/22 patients the 67 Ga scan and chest radiograph were positive simultaneously. In the other 11/22 patients with positive scans chest radiographs were initially negative but showed pathology in 5 cases within 1-2 weeks. The reason for positive scans in most cases was an opportunistic lung infection; other forms of pneumonia were only observed in two cases. The defined uptake ratio demonstrated to be a highly sensitive parameter for monitoring pneumonia and the effects of therapy in follow-up studies. In conclusion, quantitative 67 Ga scintigraphy proved to be a reliable and highly sensitive method for primary detection and follow-up of opportunistic pneumonias in patients with AIDS. (orig.) [de

  20. Effects of buffers and pH on in vitro binding of 67Ga by L1210 leukemic cells

    International Nuclear Information System (INIS)

    Glickson, J.D.; Webb, J.; Gams, R.A.

    1974-01-01

    The effect of sodium nitrate and a series of buffers on in vitro 67 Ga binding to L1210 leukemic cells at pH 6.8 +- 0.2 and 37 0 at concentrations of 10 -7 to 10 -2 M has been investigated. The relative ability of these agents to inhibit cellular incorporation of 67 Ga is given. Inhibition probably results from formation of gallium(III) complexes which are either impermeable to the tumor membrane or which compete with intracellular receptor complexes. However, direct interaction of buffers with the cell membrane or with gallium(III) receptors, as well as effects of buffers on cellular metabolism, have not been excluded. A monotonic decrease in the cellular incorporation of 67 Ga occurs between pH 6.2 and 7.8 in the presence of the inert buffer, 10 -2 M morpholinopropane sulfonic acid. (U.S.)

  1. Clinical study of 67Ga labelled human fibrinogen for detection of thrombi

    International Nuclear Information System (INIS)

    Katsuura, Yutaka

    1988-01-01

    The usefulness to detect thrombi by Ga-67 labelled human fibrinogen (Ga-F) was investigated in 22 patients with various diseases who had thrombi or were suspected to have thrombi. In 5 of 9 patients with aortic aneurysm, images of thrombi were obtained by Ga-F. In 1 of 2 patients with myocardial infarction, left ventricular thrombi were detected. In 1 of 5 patients with mitral stenosis, left atrial thrombus was recognized. Of these patients, in 2 patients who have no evidence of thrombi confirmed at another methods, thrombi were detected by Ga-F. In 6 out of 8 patients with thrombi confirmed at echocardiography or computed tomography, thrombi were detected by Ga-F. In these patients, 2 patients with negative images were treated by antithromboticdrugs. In 7 patients, both Ga-F and In-111 labelled platelets (In-P) were comparatively studied simultaniuosly. No difference in the sensitivity of the detection of thrombi were recognized between two groups. The images of thrombi by both Ga-F and In-P were detected positively in 3 patients and were not found in 4 patients. However, the handling of Ga-F method was much easier than that of In-P method. In conclusion, Ga-F could be useful for the detection of thrombi in various thrombotic diseases. Fibrinogen kinetic studies using Ga-F were performed. Fibrinogen turnover rates (FTR) in the cases with positive image by Ga-F were higher than those in the cases with Ga-F negative image. (positive : 24.3 ± 9.5 mg/kg/day, negative : 19.7 ± 8.5 mg/kg/day) The results of kinetic studies by Ga-F were similar to those by 1 - 125 fibrinogen. (author)

  2. Positive /sup 67/Ga-citrate scintigraphy: Vertebral, satellite lymph node and gallbladder foci in a case of gastroenteritis with salmonella

    Energy Technology Data Exchange (ETDEWEB)

    Popa, N; Lens, E; Dubois, J L; Blase, F

    1982-03-01

    We report a case of salmonella gastroenteritis with recurrent fever and sepsis, slight transient lumbar pain and positive /sup 67/Ga-citrate scintigraphy. The /sup 67/Ga scan made a major contribution to the positive diagnosis of a subclinical spondylodiscite and to the correct treatment leading to the disappearance of the infectious foci.

  3. Sialoscintigraphy, dacryoscintigraphy, and /sup 67/Ga-scintigraphy in SJOGREN's syndrome

    Energy Technology Data Exchange (ETDEWEB)

    De Rossi, G.

    1988-10-01

    In 68 cases of SJOGREN's syndrome (SS) dacryoscintigraphy (DS), sialoscintigraphy (SIS), and /sup 67/Ga scintigraphy (GS) were performed along with other diagnostic examinations. Pre- and post-therapy results were available. The DS, SIS, and GS triad proves to be a simple, sensitive, and easy repeatable method to improve the diagnosis and follow-up of SS.

  4. Effect of vacancies on the structure and properties of Ga{sub 2}(Se{sub 0.33}Te{sub 0.67}){sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Abdul-Jabbar, N. M. [Department of Nuclear Engineering, University of California, Berkeley, California 94720 (United States); Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Materials Department, University of California, Santa Barbara, California 93106 (United States); Forrest, T. R. [European Synchrotron Radiation Facility, BP 220, F-38043 Grenoble Cedex (France); Department of Physics, University of California, Berkeley, California 94720 (United States); Gronsky, R. [Department of Materials Science and Engineering, University of California, Berkeley, California 94720 (United States); Bourret-Courchesne, E. D. [Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Wirth, B. D. [Department of Nuclear Engineering, University of California, Berkeley, California 94720 (United States); Department of Nuclear Engineering, University of Tennessee, Knoxville, Tennessee 37996 (United States)

    2015-08-28

    Ga{sub 2}(Se{sub 0.33}Te{sub 0.67}){sub 3} belongs to a family of materials with large intrinsic vacancy concentrations that are being actively studied due to their potential for diverse applications that include thermoelectrics and phase-change memory. In this article, the Ga{sub 2}(Se{sub 0.33}Te{sub 0.67}){sub 3} structure is investigated via synchrotron x-ray diffraction, electron microscopy, and x-ray absorption experiments. Diffraction and microscopy measurements showed that the extent of vacancy ordering in Ga{sub 2}(Se{sub 0.33}Te{sub 0.67}){sub 3} is highly dependent on thermal annealing. It is posited that stoichiometric vacancies play a role in local atomic distortions in Ga{sub 2}(Se{sub 0.33}Te{sub 0.67}){sub 3} (based on the fine structure signals in the collected x-ray absorption spectra). The effect of vacancy ordering on Ga{sub 2}(Se{sub 0.33}Te{sub 0.67}){sub 3} material properties is also examined through band gap and Hall effect measurements, which reveal that the Ga{sub 2}(Se{sub 0.33}Te{sub 0.67}){sub 3} band gap redshifts by ≈0.05 eV as the vacancies order and accompanied by gains in charge carrier mobility. The results serve as an encouraging example of altering material properties via intrinsic structural rearrangement as opposed to extrinsic means, such as doping.

  5. Tumor affinity of radiolabeled peanut agglutinin compared with that of Ga-67 citrate in animal models

    International Nuclear Information System (INIS)

    Yokoyama, K.; Aburano, T.; Watanabe, N.; Kawabata, S.; Ishida, H.; Mukai, K.; Tonami, N.; Hisada, K.

    1985-01-01

    Peanut agglutinin (PNA) binds avidly to the immunodominant group of the tumor associated T antigen. The purpose of this study was to evaluate oncodiagnostic potential of radiolabeled PNA in animal models. PNA was labeled with I-125 or I-131 by Iodogen and also with In-111 by cyclic DTPA anhydride. The biological activity of PNA was examined by a hemaglutination titer with a photometer before and after labeling. Animal tumor models used were Lewis Lung Cancer(LLC), B-16 Melanotic Melanoma(MM), Yoshida Sarcoma(YS), Ehrlich Ascites Tumor(EAT and Hepatoma AH109A(HAH). Inflammatory tissue induced by turpentine oil was used as an abscess model. Serial scintigraphic images were obtained following IV injections of 100 μCi of I-131 or In-111-DTPA-PNA. The tumor affinity of Ga-67 citrate was studied to compare that of radiolabeled PNA. Tissue biodistribution was studied in EAT bearing mice. All of these tumor models except HAH were clearly visible by radiolabeled PNA without subtraction techniques. In the models of LLC and EAT, PNA showed the better accumulation into the tumor tissue than Ga-67 citrate. In YS and MM, PNA represented almost the same accumulation as Ga-67 citrate. The localization of PNA into abscess tissue wasn't found although Ga-67 citrate markedly accumulated into abscess tissue as well as tumor tissue. The clearance of PNA from tumor was slower than those from any other organs. Tumor to muscle ratio was 5.1 at 48hrs. and tumor to blood ratio increased with time to 2.3 at 96hrs. These results suggested that radiolabeled PNA may have a potential in the detection of tumor

  6. Development of methods for the purification of {sup 67}Ga and {sup 68}Ga for biomolecules labeling; Desenvolvimento de metodos de purificacao do {sup 67}Ga e {sup 68}Ga para a marcacao de biomoleculas

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Renata Ferreira

    2012-07-01

    For more than fifty years, the long-lived {sup 68}Ge/{sup 68}Ga generators have been in development, obtaining {sup 68}Ga without the need of having in house cyclotron, which is a considerable convenience for PET centers that have no nearby cyclotrons. {sup 68}Ga decays 89% by positron emission and low photon emission (1077 keV) and the physical half life of 67.7 minutes is compatible with the pharmacokinetics of low biomolecular weight substances like peptides and antibody fragments. Moreover, its established metallic chemistry allows it to be stably bound to the carrier peptide sequence via a suitable bifunctional chelator, such as DOTA. All these reasons together with the technology of PET/CT allowed advances in molecular imaging, in particular in the diagnosis of neuroendocrine diseases. However, the eluate from the commercial {sup 68}Ge/{sup 68}Ga generators still contains high levels of long lived {sup 68}Ge, besides other metallic impurities, which competes with {sup 68}Ga with a consequent reduction of the labeling yield of biomolecules, such as Fe{sup 3+} and Zn{sup 2+}. Thus, the lower the amount of impurities in the eluate, the competition between the radiolabeled and unlabeled peptide by the receptor will be smaller and the quality of imaging will be better, a subsequent purification step is needed after the generator elution. The aim of this work is to evaluate different purifications methods of {sup 68}Ga to label biomolecules, with emphasis on the study of the chemical impurities contained in the eluate and to develop a new purification method. Several purification methods were studied. Many cationic resin were tested simulating the commercial process. {sup 68}Ga is adsorbed in cationic resin, which is not commercial available and eluted in acid/acetone solution. The use of minor particles of cationic resin AG50W-X4 (200-400 mesh) showed the best results. An innovate method was the extraction chromatography, which is based on the absorption of

  7. What is the difference in the hybrid imaging techniques - SPECT/CT and PET-CT and is there any advantage of their application?

    International Nuclear Information System (INIS)

    Kostadinova, I.

    2012-01-01

    The hybrid imaging methods - Single Photon Emission Tomography-Computer Tomography /SPECT-CT / and Positron Emission Tomography-Computer Tomography / PET-CT/ allow receiving of combined image of two different techniques. In such a way it is possible to superimpose detailed anatomical image of the multislice spiral computer tomography with specific and sensitive molecular images of the SPECT and PET in a single study, allowing utilization of the full possibilities of the both techniques. They have advantages and disadvantages, which basically stem from the differences in the used radiopharmaceuticals and their physical properties. In PET- CT - positron emitters are applied, most often 18F and 11C, while in SPECT-CT - single photon emitters, most often 99m Tc and 131 I. A disadvantage of PET is a high cost, which is produced in cyclotron and its logistics is complicated. The great advantage of PET is its better spatial resolution, compared to SPECT, because of the possibility for simultaneous detection of pared photons and better registration. These techniques, especially PET-CT are nowadays the most increasing imaging methods in the world in making diagnosis, staging and following the effect of treatment in patients with oncological, neurological, cardiological, orthopedic diseases and infections. Recently, they are applied for the purposes of radiotherapy planning on the basis of the metabolically active tumor. As a final result, compared to the conventional techniques - roentgenography, CT and MRI, it is possible in many cases to make an early and more precise diagnosis, saving patients' time and using most appropriate treatment. As a conclusion it is clear, that the hybrid imaging has future and its application will increase. (author)

  8. Diffuse lung uptake (DLU) on Ga-67 scintigraph: Clinical, radiologic and pathologic correlation

    International Nuclear Information System (INIS)

    Sy, W.M.; Seo, I.S.; Vieira, J.; Zaman, M.

    1985-01-01

    Review, analysis and correlation (clinical, radiologic and pathologic) of 29 consecutive adults (16 drug addicts and/or homosexuals) with DLU on Ga-67 scintigraph were made. Diffuse increased uptake of at least 75% of both lungs was considered as DLU. WFOF cameras were used to obtain 24 to 96 hr. scintigraphs after IV injection of 3-5 mCi of Ga-67 citrate. In 26, tissue diagnosis established: pneumocystis carinii (PC) 15, miliary tuberculosis (TB) 3, sarcoidosis (SR) 3, drug-induced toxicity 2, and toxoplasmosis (TX), primary hyperparathyroidism and nonspecific lymphocytic pneumonia-one each. In two with breast and one with esophageal carcinomas, no lung tissue diagnosis was sought. Concurrent chest x-rays were negative in 16, but in 7/16, lung infiltrate was later documented. An average of 31 days elapsed before x-rays became positive in four with PC, 7 days in two with TB, and 22 days in one with TX. In 13, concurrent x-rays showed lung infiltrate, but in 6, only subtle, localized rather than diffuse infiltrate was noted. Fourteen of 29 had at least two Ga-67 studies. In 12 (7 PC, 2 TB, 3 SR) of 14 whose repeat studies showed significant to total disappearance of DLU, all did well clinically. In two whose initial studies were negative or equivocal, they became clinically worse when the repeat study showed DLU. In three others (2 PC, 1 TX) who died, their single studies recorded intense DLU. DLU on gallium scintigraph indicated a variety of pathology. In 55.2%, gallium scintigraph predated x-ray findings by a few days to weeks. In 20.3%, x-ray findings were only subtle or localized. Scintigraphic changes correlated well with the clinical courses in various diseases

  9. Affinity of /sup 169/Yb, /sup 67/Ga and /sup 111/In for malignant tumor. II. Comparison of tumor affinity among /sup 169/Yb, /sup 67/Ga, and /sup 111/In

    Energy Technology Data Exchange (ETDEWEB)

    Ando, I [Kanazawa Univ. (Japan). School of Medicine

    1975-10-01

    Comparisons of biological behavior of /sup 169/Yb-citrate and /sup 111/In-citrate and /sup 67/Ga-citrate in tumor tissue were performed by macro-autoradiography as well as by subcellular fractionation according to the method of Hogeboom and Schneider, using Yoshida sarcoma-bearing rats and Ehrlich tumor-bearing mice. The uptake of /sup 169/Yb, /sup 67/Ga and /sup 111/In into the tumor and various organs was assayed at 10, 30, 60 and 120 minutes after intravenous injection, using the rats subcutaneously transplanted with Yoshida sarcoma. Autoradiographical findings showed that the uptake of these nuclides was predominant in viable tumor tissue rather than in necrotic tumor tissue. Among subcellular fractions of Ehrlich tumor, most of the radioactivity was localized in the supernatant fraction and a small amount of radioactivity was found in the nuclear, mitochondria and microsome fractions. In Yoshida sarcoma, the results were almost similar in the three nuclides. And the specific activities of protein (cpm/mg) of these four fractions were not greatly different in the three nuclides. After intravenous injection of these nuclides, they were rapidly taken up into the tumor, and not excreted out of the tumor. It is a well-known fact that /sup 169/Yb, /sup 67/Ga and /sup 111/In are not sulfur coordinators, but weak nitrogen coordinators. Considering the above-described facts, it is presumed that the chemical bond of these elements is not a chelate ring, but anionic bond. From an in vitro adsorption test of these nuclides with the hydroxy-apatite crystal and cation exchange resin, it is presumed that the reason for the strong affinity of /sup 169/Yb to the bone is attributed to the fact that /sup 169/Yb stays mostly in cation form in the blood.

  10. Applying standardized uptake values in gallium-67-citrate single-photon emission computed tomography/computed tomography studies and their correlation with blood test results in representative organs.

    Science.gov (United States)

    Toriihara, Akira; Daisaki, Hiromitsu; Yamaguchi, Akihiro; Yoshida, Katsuya; Isogai, Jun; Tateishi, Ukihide

    2018-05-21

    Recently, semiquantitative analysis using standardized uptake value (SUV) has been introduced in bone single-photon emission computed tomography/computed tomography (SPECT/CT). Our purposes were to apply SUV-based semiquantitative analytic method for gallium-67 (Ga)-citrate SPECT/CT and to evaluate correlation between SUV of physiological uptake and blood test results in representative organs. The accuracy of semiquantitative method was validated using an National Electrical Manufacturers Association body phantom study (radioactivity ratio of sphere : background=4 : 1). Thereafter, 59 patients (34 male and 25 female; mean age, 66.9 years) who had undergone Ga-citrate SPECT/CT were retrospectively enrolled in the study. A mean SUV of physiological uptake was calculated for the following organs: the lungs, right atrium, liver, kidneys, spleen, gluteal muscles, and bone marrow. The correlation between physiological uptakes and blood test results was evaluated using Pearson's correlation coefficient. The phantom study revealed only 1% error between theoretical and actual SUVs in the background, suggesting the sufficient accuracy of scatter and attenuation corrections. However, a partial volume effect could not be overlooked, particularly in small spheres with a diameter of less than 28 mm. The highest mean SUV was observed in the liver (range: 0.44-4.64), followed by bone marrow (range: 0.33-3.60), spleen (range: 0.52-2.12), and kidneys (range: 0.42-1.45). There was no significant correlation between hepatic uptake and liver function, renal uptake and renal function, or bone marrow uptake and blood cell count (P>0.05). The physiological uptake in Ga-citrate SPECT/CT can be represented as SUVs, which are not significantly correlated with corresponding blood test results.

  11. Advances in SPECT Instrumentation (Including Small Animal Scanners). Chapter 4

    International Nuclear Information System (INIS)

    Di Domenico, G.; Zavattini, G.

    2009-01-01

    Fundamental major efforts have been devoted to the development of positron emission tomography (PET) imaging modality over the last few decades. Recently, a novel surge of interest in single photon emission computed tomography (SPECT) technology has occurred, particularly after the introduction of the hybrid SPECT-CT imaging system. This has led to a flourishing of investigations in new types of detectors and collimators, and to more accurate refinement of reconstruction algorithms. Along with SPECT-CT, new, fast gamma cameras have been developed for dedicated cardiac imaging. The existing gap between PET and SPECT in sensitivity and spatial resolution is progressively decreasing, and this trend is particularly apparent in the field of small animal imaging where the most important advances have been reported in SPECT tomographs. An outline of the basic features of SPECT technology, and of recent developments in SPECT instrumentation for both clinical applications and basic biological research on animal models is described. (author)

  12. Utility of combined 99mTc-phosphate and 67Ga imaging in diagnosis of septic arthritis

    International Nuclear Information System (INIS)

    Seto, H.; Tonami, H.; Hisada, K.

    1978-01-01

    A case of septic arthritis diagnosed by combined 99m Tc-phosphate and 67 Ga imaging, which preceded positive cultures of the infecting organism, is presented. A previously healthy 10-year-old girl complained of pain in the left hip with persistent fever. Initial laboratory studies showed a normal white cell count and negative blood cultures. A septic process was not confirmed. Blood flow studies and bone images with 99mTc-phosphate showed markedly increased perfusion in the left hip joint without extension to bone. Subsequent 67 Ga images revealed a marked increase in radioactivity in the same region, indicating the presence of a septic process. Serial blood cultures and arthrocentesis showed Staphylococcus aureus. The patient improved on antibiotics

  13. Source of Gallium-67 in gastrointestinal contents: concise communication

    International Nuclear Information System (INIS)

    Chen, D.C.; Scheffel, U.; Camargo, E.E.; Tsan, M.F.

    1980-01-01

    The sources of Ga-67 in gastrointestinal (GI) contents, and factors affecting its secretion were studied in rats. To prevent loss of fecal Ga-67, the anus was sutured before intravenous injection of Ga-67 citrate. Secretion of Ga-67 into the contents of the GI tract was rapid, 3, 6, and 9% of the injected dose were secreted at 1, 6, and 24 hr after injection, respectively. In contrast, Ga-67 concentration in the GI tissues remained relatively constant throughout this period. Analysis of Ga-67 contents of various parts of the GI tract revealed that small intestine is its major source, contributing 60% while the bile contributes 20%, large intestine 10%, esophagus and stomach 10%. Feeding had no effect on the Ga-67 secretion into GI contents. In contrast, the serum unbound iron-binding capacity (UIBC) played an important role in the GI secretion of Ga-67; reducing the serum UIBC reduced the Ga-67 secretion into GI contents

  14. Classification of Two Class Motor Imagery Tasks Using Hybrid GA-PSO Based K-Means Clustering.

    Science.gov (United States)

    Suraj; Tiwari, Purnendu; Ghosh, Subhojit; Sinha, Rakesh Kumar

    2015-01-01

    Transferring the brain computer interface (BCI) from laboratory condition to meet the real world application needs BCI to be applied asynchronously without any time constraint. High level of dynamism in the electroencephalogram (EEG) signal reasons us to look toward evolutionary algorithm (EA). Motivated by these two facts, in this work a hybrid GA-PSO based K-means clustering technique has been used to distinguish two class motor imagery (MI) tasks. The proposed hybrid GA-PSO based K-means clustering is found to outperform genetic algorithm (GA) and particle swarm optimization (PSO) based K-means clustering techniques in terms of both accuracy and execution time. The lesser execution time of hybrid GA-PSO technique makes it suitable for real time BCI application. Time frequency representation (TFR) techniques have been used to extract the feature of the signal under investigation. TFRs based features are extracted and relying on the concept of event related synchronization (ERD) and desynchronization (ERD) feature vector is formed.

  15. Clinical evaluation of stress thallium spect in ischemic heart disease

    International Nuclear Information System (INIS)

    Sui, Osamu; Kimura, Nazuna; Soeki; Takeshi; Takeichi, Naoki; Shinohara, Hisanori; Tamura, Yoshiyuki; Fukuda, Nobuo

    1997-01-01

    Thallium SPECT was performed in patients with significant coronary artery stenosis, 67 cases were after maximal exercise and 74 cases were during coronary vasodilation induced by ATP (adenosine triphosphate) infusion. In patients suspected of angina pectoris, the sensitivity, specificity and predictive accuracy for detection of coronary artery disease (CAD) were 88%, 78% and 82% for exercise SPECT, and 100%, 72% and 84% for ATP SPECT studies, respectively. In patients with old myocardial infarction, these were 73%, 100% and 88% for exercise SPECT and 71%, 100% and 81% for ATP SPECT. These were 75%, 49% and 60% for treadmill exercise test in the patient group including both angina and myocardial infarction. For detection of diseased vessels, the diagnostic accuracy for left anterior descending artery and right coronary artery lesions was almost equal for ATP and exercise SPECT study, but ATP SPECT study was more sensitive than exercise SPECT study in detection of left circumflex artery lesions. ATP as well as exercise SPECT studies occasionally gave false positive results in patients with single-vessel disease. ATP as well as exercise SPECT studies underestimated the severity of multi-vessel disease. In general, the results of ATP SPECT imaging were highly concordant with the results of exercise SPECT imaging. ATP stress thallium SPECT imaging provided a safe and highly accurate diagnostic tool for detection of CAD. (author)

  16. The role of brain SPECT in children with epilepsy

    International Nuclear Information System (INIS)

    Liu Xingdang; Liu Yongchang; Lin Xiangtong

    1996-01-01

    The rCBF brain SPECT with 99m Tc-HMPAO was performed in 15 children with interictal epilepsy, and some cases were compared with EEG, X-ray CT and MRI. The results showed that the positive rate of SPECT was the highest (93.33%,), then the EEG (92.31%), and the CT and MRI were the lowest (66.67% and 75%). This study indicated that brain SPECT was an effective method for diagnosis and foci localization in epileptic children, and also was useful to the study of prognosis and relationship between changes of rCBF and progress in clinical pictures

  17. Bone SPECT-CT: An additional diagnostic tool for undiagnosed wrist pain.

    Science.gov (United States)

    Shirley, R A; Dhawan, R T; Rodrigues, J N; Evans, D M

    2016-10-01

    Diagnosis of wrist pain can be difficult to determine with clinical examination and conventional imaging techniques alone. Bone SPECT-CT (single-photon emission tomography with computerized tomography) is a hybrid imaging technique that overlays functional bone scintigraphy in tomographic/3D mode with conventional CT. Data from the two modalities are complementary; areas of abnormal bone metabolism can be localized with anatomical precision, hitherto lacking in conventional bone scans, while structural information from the CT scan further embellishes the diagnostic information. Over the last 6 years, one surgeon (David Evans) has used bone SPECT and later bone SPECT-CT as an additional line of investigation. This is a series of 21 consecutive patients with wrist pain that could not be diagnostically resolved with the usual combination of history, examination, and conventional imaging, and therefore underwent bone SPECT-CT. Clinical and imaging findings, management, and outcomes of these cases are discussed to explore the potential role of this hybrid functional modality in hand and wrist surgical practice. Copyright © 2016. Published by Elsevier Ltd.

  18. A Methodology for the Hybridization Based in Active Components: The Case of cGA and Scatter Search.

    Science.gov (United States)

    Villagra, Andrea; Alba, Enrique; Leguizamón, Guillermo

    2016-01-01

    This work presents the results of a new methodology for hybridizing metaheuristics. By first locating the active components (parts) of one algorithm and then inserting them into second one, we can build efficient and accurate optimization, search, and learning algorithms. This gives a concrete way of constructing new techniques that contrasts the spread ad hoc way of hybridizing. In this paper, the enhanced algorithm is a Cellular Genetic Algorithm (cGA) which has been successfully used in the past to find solutions to such hard optimization problems. In order to extend and corroborate the use of active components as an emerging hybridization methodology, we propose here the use of active components taken from Scatter Search (SS) to improve cGA. The results obtained over a varied set of benchmarks are highly satisfactory in efficacy and efficiency when compared with a standard cGA. Moreover, the proposed hybrid approach (i.e., cGA+SS) has shown encouraging results with regard to earlier applications of our methodology.

  19. Study on SPECT image for children with cerebral infarction

    International Nuclear Information System (INIS)

    Xie Wenhuang; Xie Zhichun; Chen Yucai; Lin Haoxue; Zheng Aidong; Xie Hui

    1998-01-01

    To explore the diagnostic value of SPECT image for children with cerebral infarction (CCI), comparative research was made on 26 cases undergoing regional cerebral perfusion (rCP) image between SPECT imaging and CT scanning. The results showed that the rCP in the infarct and its distant area was decreased. The positive rate of SPECT and CT were 92.3% (24/26) and 84.5% (22/26) respectively. The difference was not significant (P = 0.67, P>0.05). But, the positive rate of SPECT image 2 days after onset in 9 CCI was 100% (9/9), significantly higher than 55.6% (5/9) in CT scanning (P = 0.04, P<0.05). These findings suggested that the SPECT imaging is a sensitive method for the early diagnosis of CCI, and also helpful for observation of the therapeutic effect and evaluation of the prognosis

  20. Validation and the limits of SPECT for patients suffering from cerebrovascular accidents. Evaluations based on simultaneous PET and SPECT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Mizukawa, Norihiko; Yano, Ichiro; Tenjin, Hiroshi (Kyoto Prefectural Univ. of Medicine (Japan)) (and others)

    1989-02-01

    Contemporaneous single photon emission computed tomography (SPECT) and positron emission tomography (PET) were performed in 10 patients with cerebrovascular accidents (CVA), whose ages ranged from 11 to 67 years. I-123-isopropyl-iodoamphetamine (IMP) and/or Tc-99m hexamethylpropyleneamine oxime (HM-PAO) were used for SPECT. Cerebral blood flow (CBF), oxygen extraction fraction (OEF), and cerebral metabolic rate for oxygen (CMRO{sub 2}) were measured by an O-15 labelled gas continuous-inhalation method. SPECT images were quite similar to CBF and CMRO{sub 2} during the chronic stage of CVA. Two patietns with vasospasm during the subacute stage had apparently low CBF and CMRO{sub 2} on PET, but did not have low perfusion on SPECT. Luxury perfusion areas were detected in 4 subacute stage patients and one chronic stage patient. A redistribution of IMP was detected in two patients with infarction during subacute stage. CMRO{sub 2} value in such an area was 2.0 ml/100 g/min. Low CBF and/or CMRO{sub 2} areas were well visualized by IMP rather than by HM-PAO SPECT. (N.K.).

  1. Silicon Detectors for PET and SPECT

    Science.gov (United States)

    Cochran, Eric R.

    Silicon detectors use state-of-the-art electronics to take advantage of the semiconductor properties of silicon to produce very high resolution radiation detectors. These detectors have been a fundamental part of high energy, nuclear, and astroparticle physics experiments for decades, and they hold great potential for significant gains in both PET and SPECT applications. Two separate prototype nuclear medicine imaging systems have been developed to explore this potential. Both devices take advantage of the unique properties of high resolution pixelated silicon detectors, designed and developed as part of the CIMA collaboration and built at The Ohio State University. The first prototype is a Compton SPECT imaging system. Compton SPECT, also referred to as electronic collimation, is a fundamentally different approach to single photon imaging from standard gamma cameras. It removes the inherent coupling of spatial resolution and sensitivity in mechanically collimated systems and provides improved performance at higher energies. As a result, Compton SPECT creates opportunities for the development of new radiopharmaceuticals based on higher energy isotopes as well as opportunities to expand the use of current isotopes such as 131I due to the increased resolution and sensitivity. The Compton SPECT prototype consists of a single high resolution silicon detector, configured in a 2D geometry, in coincidence with a standard NaI scintillator detector. Images of point sources have been taken for 99mTc (140 keV), 131I (364keV), and 22Na (511 keV), demonstrating the performance of high resolution silicon detectors in a Compton SPECT system. Filtered back projection image resolutions of 10 mm, 7.5 mm, and 6.7 mm were achieved for the three different sources respectively. The results compare well with typical SPECT resolutions of 5-15 mm and validate the claims of improved performance in Compton SPECT imaging devices at higher source energies. They also support the potential of

  2. A Methodology for the Hybridization Based in Active Components: The Case of cGA and Scatter Search

    Directory of Open Access Journals (Sweden)

    Andrea Villagra

    2016-01-01

    Full Text Available This work presents the results of a new methodology for hybridizing metaheuristics. By first locating the active components (parts of one algorithm and then inserting them into second one, we can build efficient and accurate optimization, search, and learning algorithms. This gives a concrete way of constructing new techniques that contrasts the spread ad hoc way of hybridizing. In this paper, the enhanced algorithm is a Cellular Genetic Algorithm (cGA which has been successfully used in the past to find solutions to such hard optimization problems. In order to extend and corroborate the use of active components as an emerging hybridization methodology, we propose here the use of active components taken from Scatter Search (SS to improve cGA. The results obtained over a varied set of benchmarks are highly satisfactory in efficacy and efficiency when compared with a standard cGA. Moreover, the proposed hybrid approach (i.e., cGA+SS has shown encouraging results with regard to earlier applications of our methodology.

  3. Gallium-67 uptake in meningeal sarcoidosis

    International Nuclear Information System (INIS)

    Ayres, J.G.; Hicks, B.H.; Maisey, M.N.

    1986-01-01

    A case of sarcoidosis limited to the central nervous system is described in which the diagnosis was suggested by high Ga-67 uptake in the cranial and spinal meninges. The diagnosis was confirmed by meningeal biopsy. Treatment with oral corticosteroids resulted in clinical improvement and marked reduction in Ga-67 uptake in the meninges. This is the first reported case of the central nervous system sarcoid diagnosed by Ga-67 imaging

  4. Measurement of cross sections for the 63Cu(α,γ)67Ga reaction from 5.9-8.7 MeV

    International Nuclear Information System (INIS)

    Basunia, M. Shamsuzzoha; Norman, Eric B.; Shugart, Howard A.; Smith, Alan R.; Dolinski, Michelle J.; Quiter, Brian J.

    2004-01-01

    We have measured cross sections for the 63Cu(alpha,gamma)67Ga reaction in the 5.9-8.7 MeV energy range using an activation technique. Natural Cu foils were bombarded with alpha beams from the 88 Cyclotron at Lawrence Berkeley National Laboratory (LBNL). Activated foils were counted using gamma spectrometry system at LBNL's Low Background Facility. The 63Cu(alpha,gamma)67Ga cross-sections were determined and compared with the latest NON-SMOKER theoretical values. Experimental cross sections were found to be in agreement with theoretical values

  5. Combined SPECT/CT and PET/CT for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Paolo [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Larobina, Michele [Istituto di Biostrutture e Bioimmagini, Consiglio Nazionale delle Ricerche, Via Tommaso De Amicis, 95, Naples I-80145 (Italy); Di Lillo, Francesca [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Del Vecchio, Silvana [Università di Napoli Federico II, Dipartimento di Scienze Biomediche Avanzate, Via Pansini, 5, Naples I-80131 (Italy); Mettivier, Giovanni, E-mail: mettivier@na.infn.it [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy)

    2016-02-11

    In the field of nuclear medicine imaging, breast imaging for cancer diagnosis is still mainly based on 2D imaging techniques. Three-dimensional tomographic imaging with whole-body PET or SPECT scanners, when used for imaging the breast, has performance limits in terms of spatial resolution and sensitivity, which can be overcome only with a dedicated instrumentation. However, only few hybrid imaging systems for PET/CT or SPECT/CT dedicated to the breast have been developed in the last decade, providing complementary functional and anatomical information on normal breast tissue and lesions. These systems are still under development and clinical trials on just few patients have been reported; no commercial dedicated breast PET/CT or SPECT/CT is available. This paper reviews combined dedicated breast PET/CT and SPECT/CT scanners described in the recent literature, with focus on their technological aspects.

  6. Use of quantitative SPECT/CT reconstruction in 99mTc-sestamibi imaging of patients with renal masses.

    Science.gov (United States)

    Jones, Krystyna M; Solnes, Lilja B; Rowe, Steven P; Gorin, Michael A; Sheikhbahaei, Sara; Fung, George; Frey, Eric C; Allaf, Mohamad E; Du, Yong; Javadi, Mehrbod S

    2018-02-01

    Technetium-99m ( 99m Tc)-sestamibi single-photon emission computed tomography/computed tomography (SPECT/CT) has previously been shown to allow for the accurate differentiation of benign renal oncocytomas and hybrid oncocytic/chromophobe tumors (HOCTs) apart from other malignant renal tumor histologies, with oncocytomas/HOCTs showing high uptake and renal cell carcinoma (RCC) showing low uptake based on uptake ratios from non-quantitative single-photon emission computed tomography (SPECT) reconstructions. However, in this study, several tumors fell close to the uptake ratio cutoff, likely due to limitations in conventional SPECT/CT reconstruction methods. We hypothesized that application of quantitative SPECT/CT (QSPECT) reconstruction methods developed by our group would provide more robust separation of hot and cold lesions, serving as an imaging framework on which quantitative biomarkers can be validated for evaluation of renal masses with 99m Tc-sestamibi. Single-photon emission computed tomography data were reconstructed using the clinical Flash 3D reconstruction and QSPECT methods. Two blinded readers then characterized each tumor as hot or cold. Semi-quantitative uptake ratios were calculated by dividing lesion activity by background renal activity for both Flash 3D and QSPECT reconstructions. The difference between median (mean) hot and cold tumor uptake ratios measured 0.655 (0.73) with the QSPECT method and 0.624 (0.67) with the conventional method, resulting in increased separation between hot and cold tumors. Sub-analysis of 7 lesions near the separation point showed a higher absolute difference (0.16) between QPSECT and Flash 3D mean uptake ratios compared to the remaining lesions. Our finding of improved separation between uptake ratios of hot and cold lesions using QSPECT reconstruction lays the foundation for additional quantitative SPECT techniques such as SPECT-UV in the setting of renal 99m Tc-sestamibi and other SPECT/CT exams. With robust

  7. The diagnostic value of monoclonal antibody scan (leucoscan) compared with 99mTc MDP bone scan and Ga 67 in diagnosing bone and joint infection

    International Nuclear Information System (INIS)

    Koukouraki, S.I.; Velidaki, A.; Prassopoulos, V.; Karkavitsas, N.; Vavouranakis, H.; Hatjipavlou, A.

    2002-01-01

    Full text: Nowadays different radiopharmaceuticals have been developed as 99mTc MDP, 67Ga citrate, 111In oxine- and 99mTc HMPAO labeled leucocytes for the accurate localization of bone/joint infection, but all of them have limitations that encouraged the search of new agents characterized from high and early uptake in infectious/inflammatory tissues, low toxicity and no accumulation in non inflamed tissues. The purpose of this study is to compare the diagnostic value of a 99mTc labeled antigranulocyte Fab' fragment (Leucoscan) with 99mTc MDP bone scan and 67 Ga. The monoclonal antibody, Leucoscan, is an IgG murine Fab' fragment directed against a NCA-90 epitope located on the surface of granulocytes. 45 patients with suspected bone and joint infection (18 total hip prosthesis, 4 knee prosthesis, 8 vertebral infection and 15 long bones) were included in this study. All patients underwent conventional Rx, bone scan, 67Ga scan and Leucoscan. Three phase 99mTc MDP bone scan and 67Ga scan were performed using standard procedures. For Leucoscan the antibody was labeled with 25 mCi of 99mTc and was infected intravenously over 30 seconds. Ten minutes planar images were taken 1 h and 2 hrs p.i using a GE Millennium γ camera provided with a LEGP collimator. Images were evaluated as score 1 (no abnormal uptake), score 2 (probably positive), score 3 (definitely infected) according the intensity of abnormally increased uptake. Results were compared with 99mTc MDP bone scan and 67Ga scans. The final diagnosis was given by the surgical verification with histopathology or culture. All 45 patients had pathologic proof of presence/absence of bone and joint infection. 36/45 were positive for bone or joint infection and 9/45 were negative.30/36 patients with surgically proven bone and joint infection had true positive Leucoscan, 26/36 had true positive MDP bone scan and 20/36 true positive 67Ga scan. Nine out of 9 patients with proven absence of inflammation had true negative

  8. Radiation risk and protection of patients in clinical SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Brix, Gunnar; Nekolla, Elke A.; Nosske, Dietmar [Federal Office for Radiation Protection, Department of Medical and Occupational Radiation Protection, Oberschleissheim (Germany); Borowski, Markus [Klinikum Braunschweig, Institute of Radiation Diagnostics and Nuclear Medicine, Braunschweig (Germany)

    2014-05-15

    Clinical studies have demonstrated that hybrid single photon emission computed tomography (SPECT)/CT for various diagnostic issues has an added value as compared to SPECT alone. However, the combined acquisition of functional and anatomical images can substantially increase radiation exposure to patients, in particular when using a hybrid system with diagnostic CT capabilities. It is, therefore, essential to carefully balance the diagnostic needs and radiation protection requirements. To this end, the evidence on health effects induced by ionizing radiation is outlined. In addition, the essential concepts for estimating radiation doses and lifetime attributable cancer risks associated with SPECT/CT examinations are presented taking into account both the new recommendations of the International Commission on Radiological Protection (ICRP) as well as the most recent radiation risk models. Representative values of effective dose and lifetime attributable risk are reported for ten frequently used SPECT radiopharmaceuticals and five fully diagnostic partial-body CT examinations. A diagnostic CT scan acquired as part of a combined SPECT/CT examination contributes considerably to, and for some applications even dominates, the total patient exposure. For the common SPECT and CT examinations considered in this study, the lifetime attributable risk of developing a radiation-related cancer is less than 0.27 %/0.37 % for men/women older than 16 years, respectively, and decreases markedly with increasing age at exposure. Since there is no clinical indication for a SPECT/CT examination unless an emission scan has been indicated, the issue on justification comes down to the question of whether it is necessary to additionally acquire a low-dose CT for attenuation correction and anatomical localization of tracer uptake or even a fully diagnostic CT. In any case, SPECT/CT studies have to be optimized, e.g. by adapting dose reduction measures from state-of-the-art CT practice, and

  9. Enhanced performance of GaN-based light-emitting diodes with graphene/Ag nanowires hybrid films

    Directory of Open Access Journals (Sweden)

    Zhi Li

    2013-04-01

    Full Text Available Incorporating Ag nanowires with graphene resulted in improved electrical conductivity and enhanced contact properties between graphene and p-GaN. The graphene/AgNWs hybrid films exhibited high transmittance and lower sheet resistance compared to bare graphene. The specific contact resistance between graphene and p-GaN reduced nearly an order of magnitude with the introduction of AgNWs. As a result, light emitting diodes based on the hybrid films showed 44% lower forward voltage and 2-fold higher light output power. The enhanced performance was attributed to the bridging by AgNWs of cracks, grain boundaries in graphene and the reduction of Schottky barrier height at graphene/ p-GaN interface.

  10. 67GA-citrate scintiscanning for the staging and course contral of the Hodgkin's disease

    International Nuclear Information System (INIS)

    Baecher, F.M.

    1982-01-01

    266 67 Ga scintigrams of 93 patients in treated and untreated states were evaluated and compared to the histological, radiological, and clinical data. A difference in the storing characteristics of the various histological subtypes of lymphogranulomatosis could not be proven. In the intrathoracic space, radiogallium scintiscanning is of the same value as radiological diagnosing due to its congruency with the X-ray picture in 88.6% of the untreated and 94.2% of the treated cases. Comparing to the X-ray picture, radiogallium scintiscanning provides also additional information: a statement concerning the vitality of the Hodgkin tissue thus informing also about the efficiency of the treatment carried out. After an effective radio or chemotherapy, the scintigraphs show no more scintigraphically provable storing foci. In the abdominal region, the method does not permit to make sufficient statements on affection of liver, spleen, or the abdominal lymph node stations. For our group of patients, we calculated 0.3% falsely positive and 4.0% falsely negative results. The results we obtained emphasize the value of 67 Ga-scintiscanning in the primary staging and therapy control of the morbus Hodgkin as well as in diagnosing relapses. (orig./MG)F [de

  11. Investigation of the gallium-67 citrate hilar accumulation

    International Nuclear Information System (INIS)

    Suto, Yuji

    1987-01-01

    To study the 67 Ga hilar accumulation, author quantitatively analyzed 67 Ga scintigrams of patients having no chest disease and normal chest roentgenograms. Relationship between hilar accumulation and smoking was quantitatively and experimentally studied. The conclusions were as follows: 1. There was significant relationship between smoking and 67 Ga hilar accumulation but there was no significant relationship between aging and the hilar accumulation. 2. The 67 Ga uptake of the hilar lymph node of smoked rat was higher than that of control group on microautoradiogram. The histological finding of the hilar lymph node of smoked rat was sinus histiocytosis. 3. Activated histiocytosis of hilar lymphatic sinus by some factors including smoking seemed to be responsible for 67 Ga hilar accumulation, of which mechanism was unknown. (author)

  12. Application of SPECT/CT imaging in the diagnosis of benign diseases

    International Nuclear Information System (INIS)

    Garcheva, M.; Demirev, A.

    2014-01-01

    The application of recently introduced hybrid nuclear medicine methods gains importance in a variety of clinical fields, mainly because of the unique combination between functional and anatomical data provided by those methods and their capability for a precise localization of pathological processes. Single photon emission computed tomography, combined with computed tomography (SPECT/CT) is one of those methods. Its role in nuclear cardiology is important, because it provides quick attenuation correction and calculates the calcium score. In nuclear endocrinology SPECT/CT participates in thyroid and parathyroid examinations, especially in cases, where there is a need for localization of ectopic parathyroid or thyroid tissue. In nuclear pulmonology, one of the best ways to attribute certain changes seen on the SPECT, to the zone of interest on the CT, is to study the fused images obtained from the SPECT/ CT scanner. In cases of suspected infection and inflammation, fused images are indispensable for accurate localization of the involved tissue (structure) and for discrimination between normal/abnormal uptake. Careful reading of the CT component (even low-dose) is related (in 10% of cases) to clinically important incidental findings: effusions, tumors, metastases or lymph node pathology. SPECT/CT increases the specificity of the examinations and improves significantly the localization of pathological processes. It provides additional information, shortens the diagnostic algorithm and influences the extent of surgical procedures. In many hybrid examinations the preferred CT component is a low-dose one, without considerable radiation exposure. The opportunity to combine nuclear medicine techniques and contrast CT images, aiming at better diagnosis needs further development. SPECT/CT provides important additional information and more accurate diagnostics in patients with benign diseases. (authors) Key words: SPECT/CT. BENIGN DISEASES

  13. X-ray Imaging Using a Hybrid Photon Counting GaAs Pixel Detector

    CERN Document Server

    Schwarz, C; Göppert, R; Heijne, Erik H M; Ludwig, J; Meddeler, G; Mikulec, B; Pernigotti, E; Rogalla, M; Runge, K; Smith, K M; Snoeys, W; Söldner-Rembold, S; Watt, J

    1999-01-01

    The performance of hybrid GaAs pixel detectors as X-ray imaging sensors were investigated at room temperature. These hybrids consist of 300 mu-m thick GaAs pixel detectors, flip-chip bonded to a CMOS Single Photon Counting Chip (PCC). This chip consists of a matrix of 64 x 64 identical square pixels (170 mu-m x 170 mu-m) and covers a total area of 1.2 cm**2. The electronics in each cell comprises a preamplifier, a discriminator with a 3-bit threshold adjust and a 15-bit counter. The detector is realized by an array of Schottky diodes processed on semi-insulating LEC-GaAs bulk material. An IV-charcteristic and a detector bias voltage scan showed that the detector can be operated with voltages around 200 V. Images of various objects were taken by using a standard X-ray tube for dental diagnostics. The signal to noise ratio (SNR) was also determined. The applications of these imaging systems range from medical applications like digital mammography or dental X-ray diagnostics to non destructive material testing (...

  14. Hybrid Back Surface Reflector GaInAsSb Thermophotovoltaic Devices

    International Nuclear Information System (INIS)

    RK Huang; CA Wang; MK Connors; GW Turner; M Dashiell

    2004-01-01

    Back surface reflectors have the potential to improve thermophotovoltaic (TPV) device performance though the recirculation of infrared photons. The ''hybrid'' back-surface reflector (BSR) TPV cell approach allows one to construct BSRs for TPV devices using conventional, high efficiency, GaInAsSb-based TPV material. The design, fabrication, and measurements of hybrid BSR-TPV cells are described. The BSR was shown to provide a 4 mV improvement in open-circuit voltage under a constant shortcircuit current, which is comparable to the 5 mV improvement theoretically predicted. Larger improvements in open-circuit voltage are expected in the future with materials improvements

  15. 18F-FDG hybrid PET in patients with suspected spondylitis

    International Nuclear Information System (INIS)

    Gratz, S.; Behr, T.M.; Behe, M.; Doerner, J.; Fischer, U.; Grabbe, E.; Altenvoerde, G.; Meller, J.; Becker, W.

    2002-01-01

    This study investigated the value of fluorine-18 2'-deoxy-2-fluoro-D-glucose (FDG) imaging with a double-headed gamma camera operated in coincidence (hybrid PET) detection mode in patients with suspected spondylitis. Comparison was made with conventional nuclear medicine imaging modalities and magnetic resonance imaging (MRI). Sixteen patients with suspected spondylitis (nine male, seven female, mean age 59 years) prospectively underwent FDG hybrid PET (296 MBq) and MRI. For intra-individual comparison, the patients were also imaged with technetium-99m methylene diphosphonate (MDP) (555 MBq) (n=13) and/or gallium-67 citrate (185 MBq) (n=11). For FDG hybrid PET, two or three transverse scans were performed. Ratios of infected (target) to non-infected (background) (T/B) vertebral bodies were calculated. MR images were obtained of the region of interest. Patients found positive for spondylitis with MRI and/or FDG hybrid PET underwent surgical intervention and histological grading of the individual infected foci. Twelve out of 16 patients were found to be positive for spondylitis. Independent of the grade of infection and the location in the spine, all known infected vertebrae (n=23, 9 thoracic, 12 lumbar, 2 sacral) were detected by FDG hybrid PET. T/B ratios higher than 1.45±0.05 (at 1 h p.i.) were indicative of infectious disease, whereas ratios below this value were found in cases of degenerative change. FDG hybrid PET was superior to MRI in patients who had a history of surgery and suffered from a high-grade infection in combination with paravertebral abscess formation (n=2; further computed tomography was needed) and in those with low-grade spondylitis (n=2, no oedema) or discitis (n=2, mild oedema). False-positive 67 Ga citrate images (n=5: 2 spondylodiscitis, 1 aortitis, 1 pleuritis, 1 pulmonary tuberculosis) and 99m Tc-MDP SPET (n=4: 1 osteoporosis, 2 spondylodiscitis, 1 fracture) were equally well detected by FDG hybrid PET and MRI. No diagnostic problems

  16. Hydrogen Peroxide and Ozone Formation in Hybrid Gas-Liquid Electrical Discharge Reactors

    Czech Academy of Sciences Publication Activity Database

    Lukeš, Petr; Appleton, A. T.; Locke, B. R.

    2004-01-01

    Roč. 40, č. 1 (2004), s. 60-67 ISSN 0093-9994. [IEEE Industry Applications Society Annual Meeting 2002/37th./. Pittsburgh, Pennsylvania , 13.10.2002-18.10.2002] R&D Projects: GA ČR GA202/02/1026; GA MŠk ME 472 Grant - others:NSF(US) INT0086351 Keywords : hydrogen peroxide, ozone, corona discharge, water treatment, hybrid reactor Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.987, year: 2004

  17. Gallium-67 citrate localization in disseminated sporotrichosis

    International Nuclear Information System (INIS)

    Moreno, A.J.; Brazier, J.M.; Baker, F.J.; Fox, B.J.; Pittman, D.L.

    1985-01-01

    A 25-year-old woman demonstrated Ga-67 citrate accumulation within a facial cutaneous lesion and two subcutaneous nodules within the right lower extremity. Cultures of the facial lesion and one of the subcutaneous nodules grew Sporothrix schenckii. Ga-67 citrate uptake has not been reported previously with this fungal infection. Ga-67 citrate scintigraphy was helpful in defining the extent of the disease, following its course, and determining the response to therapy

  18. A combined static-dynamic single-dose imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT.

    Science.gov (United States)

    Sciammarella, Maria; Shrestha, Uttam M; Seo, Youngho; Gullberg, Grant T; Botvinick, Elias H

    2017-08-03

    analysis also produced a similar accuracy, sensitivity, and specificity. CFR was normal in 6, each with CAD on SCA with an overall accuracy of 91%, sensitivity of 80%, and specificity of 100%. The mean CFR was significantly lower for SCA detected abnormal than for normal patients (3.86±1.06 vs 1.94±0. 0.67, P < 0.001). The visually assessed image findings in static and dynamic SPECT are subjective, and may not reflect direct physiologic measures of coronary lesion based on SCA. The CFR measured with dynamic SPECT is fully objective, with better sensitivity and specificity, available only with the data generated from the dynamic SPECT method.

  19. Gallium-67 citrate imaging for the assessment of radiation pneumonitis

    International Nuclear Information System (INIS)

    Kataoka, Masaaki

    1989-01-01

    In order to evaluate its usefulness in the assessment of radiation pneumotinis, gallium-67 citrate ( 67 Ga) imaging was performed before and after radiation therapy (RT) on 103 patients with lung cancer. In 23 patients with radiation pneumonitis detected radiographically, abnormal 67 Ga uptake in sites other than tumors was found in all post-RT 67 Ga lung images. Three patterns of uptake were found: (A) focal uptake corresponding to the RT field (n=10); (B) diffuse uptake including the RT field (n=4); and (C) diffuse uptake outside the RT field (n=9). The area of 67 Ga uptake was consistent with that of interstitial pneumonitis as revealed histopathologically in 7 cases. 67 Ga uptake in pattern (C) was an indicator of poor prognosis for the patients with radiation pneumonitis. 67 Ga uptake in the patients with reversible pneumonitis disappeared with steroid therapy. Sixteen (20%) of 80 asymptomatic patients, in whose chest radiographs there was no finding of radiation pneumonitis, showed transient 67 Ga uptake. These were considered to occur in the subclinical radiation pneumonitis. These data suggest that 67 Ga imaging is more sensitive than chest radiography in the detection of radiation pneumonitis and is useful in the assessment of the extent and clinical course of radiation pneumonitis. (author)

  20. Scintigraphic discrimination of infections from cancer with 67Ga citrate and sup(99m)Tc pertechnetate

    International Nuclear Information System (INIS)

    Okuyama, Shinichi; Ito, Yasuhiko; Sato, Tachio

    1977-01-01

    A paralleled study was carried out on lung cancer and infectious lesions by scintigraphy with 67 Ga citrate and sup(99m)Tc pertechnetate. Malignancies were Ga-positive but Tc-negative whilest infective lesions were positive with both radioisotopes. The technic is simple and yet unique in that it employs radioisotopic uptake ratios which were computed by recording radioactivity over such lesions and over appropriate control sites. This technic may offer a prompt and prospective means of making a differential diagnosis of lung cancer and active lung abscesses. Confirmative value of lesion to control region counting ratio was also emphasized. (auth.)

  1. Brain SPECT. SPECT in der Gehirndiagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Feistel, H. (Erlangen-Nuernberg Univ., Erlangen (Germany). Nuklearmedizinische Klinik mit Poliklinik)

    1991-12-01

    Brain SPECT investigations have gained broad acceptance since the introduction of the lipophilic tracer Tc-99m-HMPAO. Depending on equipment and objectives in different departments, the examinations can be divided into three groups: 1. Under normal conditions and standardised patient preparation the 'rest' SPECT can be performed in every department with a tomographic camera. In cerebrovascular disease there is a demand for determination of either the perfusion reserve in reversible ischemia or prognostic values in completed stroke. In cases of dementia, SPECT may yield useful results according to differential diagnosis. Central cerebral system involvement in immunologic disease may be estimated with higher sensitivity than in conventional brain imaging procedures. In psychiatric diseases there is only a relative indication for brain SPECT, since results during recent years have been contradictory and may be derived only in interventional manner. In brain tumor diagnostics SPECT with Tl-201 possibly permits grading. In inflammatory disease, especially in viral encephalitis, SPECT may be used to obtain early diagnosis. Normal pressure hydrocephalus can be distinguished from other forms of dementia and, consequently, the necessity for shunting surgery can be recognised. 2. In departments equipped for emergency cases an 'acute' SPECT can be performed in illnesses with rapid changing symptoms such as different forms of migraine, transient global amnesia, epileptic seizures (so-called 'ictal SPECT') or urgent forms like trauma. 3. In cooperation with several departments brain SPECT can be practised as an interventional procedure in clinical and in scientific studies. (orig./MG).

  2. Bronchoalveolar lavage, serum angiotensin-converting enzyme, and 67Ga scanning in extrathoracic sarcoidosis

    International Nuclear Information System (INIS)

    Wallaert, B.; Ramon, P.; Fournier, E.; Tonnel, A.B.; Voisin, C.

    1982-01-01

    Results of bronchoalveolar lavage (BAL), 67Ga scanning, and serum angiotensin-converting enzyme (SACE) assay are compared in the assessment of pulmonary involvement in ten cases of extrathoracic sarcoidosis. Standard clinical, radiologic, and pulmonary function tests detected no pulmonary changes in these patients, but BAL demonstrated an increased alveolar lymphocytosis in eight of ten cases. SACE levels were increased in two cases, and the thoracic gallium uptake was normal in all cases. BAL appears to be the best technique for diagnosing latent pulmonary involvement in extrathoracic sarcoidosis

  3. Gallium-67 imaging in candidal esophagitis

    International Nuclear Information System (INIS)

    Rundback, J.H.; Goldfarb, C.R.; Ongseng, F.

    1990-01-01

    Ga-67 scanning has been used to evaluate esophageal carcinoma. It has demonstrated candidal infection in other body sites and, in one previous case, in the esophagus. The authors present a case of diffuse esophageal uptake of Ga-67 in esophageal candidiasis

  4. Gallium-67 imaging in candidal esophagitis

    Energy Technology Data Exchange (ETDEWEB)

    Rundback, J.H.; Goldfarb, C.R.; Ongseng, F. (Beth Israel Medical Center, New York, NY (USA))

    1990-01-01

    Ga-67 scanning has been used to evaluate esophageal carcinoma. It has demonstrated candidal infection in other body sites and, in one previous case, in the esophagus. The authors present a case of diffuse esophageal uptake of Ga-67 in esophageal candidiasis.

  5. Diagnosis of pulmonary infections with HIV (+) patients. Brought of aerosol DTPA-Tc99m and of Ga67 citrate

    International Nuclear Information System (INIS)

    Banzo, I.; Quirce, R.; Serrano, J.; Jimenez, J.; Tabuenca, O.; Carril, J.M.

    1993-01-01

    The pulmonary clearance of aerosol DTPA-Tc99m is a technology easy to use, well support by patients with immediate results. With the pneumonia at Pneumocystis Carinii (PPC), the clearance is more sensitive and more specific than the thoracic scintigraphy with Ga67. Used with a thorax radiography, results will lead to three directions: High probability of PPC, di phasic curve and very fast T50, equal inferior to 5,10 mn. Low probability of PPC, monoexponential curve and abnormal thorax radiography or di phasic curve with a value T50 superior to 5,10 mn. With these patients other explorations will be made (Ga67, biopsy) and if possible search pulmonary tuberculosis. Extra pulmonary pathology: monoexponential curve associated with a normal thoracic radiography. 2 figs

  6. Gallium-67 citrate imaging in underground coal miners

    International Nuclear Information System (INIS)

    Kanner, R.E.; Barkman, H.W. Jr.; Rom, W.N.; Taylor, A.T. Jr.

    1985-01-01

    Twenty-two underground coal workers with 27 or more years of coal dust exposure were studied with gallium-67 citrate (Ga-67) imaging. Radiographic evidence of coal workers indicates that pneumoconiosis (CWP) was present in 12 subjects. The Ga-67 scan was abnormal in 11 of 12 with, and 9 of 10 without, CWP. The Ga-67 uptake index was significantly correlated with total dust exposure (p less than 0.01) and approached significant correlation with the radiographic profusion of the nodules (0.10 greater than p greater than 0.05). There was no correlation between Ga-67 uptake and spirometric function, which was normal in this group of patients; furthermore, increased lung uptake of gallium did not indicate a poor prognosis in subjects no longer exposed to coal dust. While coal dust exposure may be associated with positive Ga-67 lung scan in coal miners with many years of coal dust exposure, the scan provided no information not already available from a careful exposure history and a chest radiograph. Since Ga-67 scanning is a relatively expensive procedure the authors would recommend that its use in subjects with asymptomatic CWP be limited to an investigative role and not be made part of a routine evaluation

  7. Electronic structure modeling of InAs/GaSb superlattices with hybrid density functional theory

    Energy Technology Data Exchange (ETDEWEB)

    Garwood, Tristan [Univ. of New Mexico, Albuquerque, NM (United States). Center for High Technology Materials; Modine, Normand A. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Krishna, S. [Univ. of New Mexico, Albuquerque, NM (United States). Center for High Technology Materials

    2016-12-18

    The application of first-principles calculations holds promise for greatly improving our understanding of semiconductor superlattices. By developing a procedure to accurately predict band gaps using hybrid density functional theory, it lays the groundwork for future studies investigating more nuanced properties of these structures. Our approach allows a priori prediction of the properties of SLS structures using only the band gaps of the constituent materials. Furthermore, it should enable direct investigation of the effects of interface structure, e.g., intermixing or ordering at the interface, on SLS properties. In this paper, we present band gap data for various InAs/GaSb type-II superlattice structures calculated using the generalized Kohn-Sham formulation of density functional theory. A PBE0-type hybrid functional was used, and the portion of the exact exchange was tuned to fit the band gaps of the binary compounds InAs and GaSb with the best agreement to bulk experimental values obtained with 18% of the exact exchange. The heterostructures considered in this study are 6 monolayer (ML) InAs/6 ML GaSb, 8 ML InAs/8 ML GaSb and 10 ML InAs/10 ML GaSb with deviations from the experimental band gaps ranging from 3% to 11%.

  8. Red light emitting solid state hybrid quantum dot-near-UV GaN LED devices

    International Nuclear Information System (INIS)

    Song, Hongjoo; Lee, Seonghoon

    2007-01-01

    We produced core-shell (CdSe)ZnSe quantum dots by direct colloidal chemical synthesis and the surface-passivation method-an overcoating of the core CdSe with a larger-bandgap material ZnSe. The (CdSe)ZnSe quantum dots(QDs) play the role of a colour conversion centre. We call these quantum dots nanophosphors. We fabricated red light emitting hybrid devices of (CdSe)ZnSe QDs and a near-UV GaN LED by combining red light emitting (CdSe)ZnSe quantum dots (as a colour conversion centre) with a near-UV(NUV) GaN LED chip (as an excitation source). A few good red phosphors have been known for UV excitation wavelengths, and red phosphors for UV excitation have been sought for a long time. Here we tested the possibility of using (CdSe)ZnSe QDs as red nanophosphors for UV excitation. The fabricated red light emitting hybrid device of (CdSe)ZnSe and a NUV GaN LED chip showed a good luminance. We demonstrated that the (CdSe)ZnSe quantum dots were promising red nanophosphors for NUV excitation and that a red LED made of QDs and a NUV excitation source was a highly efficient hybrid device

  9. Hybridization and magnetism in U(Ru, Rh)X, X=Al, Ga

    NARCIS (Netherlands)

    Sechovsky, V.; Havela, L.; Boer, de F.R.; Veenhuizen, P.A.; Sugiyama, K.; Kuroda, T.; Sugiura, T.; Ono, M.; Date, M.; Yamagishi, A.

    1992-01-01

    Results of magnetic studies of pseudoternary U(Ru, Rh)Al and U(Ru, Rh)Ga systems are presented. Reduction of the 5f-4d hybridization with increasing Rh content is reflected in a gradual transition from paramagnetic (spin fluctuation) behaviour of URuX to ferromagnetism in URhX. The huge uniaxial

  10. Biological mechanisms of gallium-67 tumor deposition

    International Nuclear Information System (INIS)

    Okuyama, Shinichi; Takeda, Shumpei; Sato, Tachio; Takusagawa, Kimihiko; Awano, Takayuki.

    1979-01-01

    This investigation was undertaken in order to clarify the tumor deposition mechanisms of 67 Ga citrate, a ''universal tumor labeler''. An interspecies comparison of various tumors in the rat and mouse indicated that its highest deposition was in the undifferentiated cell type. Amongst the siblings of experimental tumors, cellular membrane negative charge is greater in the free-cell types than the island-formers: a short-term labeling study revealed a greater 67 Ga deposition in the free-cell types. A subcellar fractionation showed an initial association of 67 Ga with the nuclear and membrane fractions, and a later transition to the lysosomal. Hypotonic lysis revealed a paralleled release of 67 Ga and lysosomal key enzymes. Morphological abnormality of the cancer lysosomes was thought to agree with their Ga retention. This property was clinically confirmed by a scintiscoring technique. Treatment with cold gallium of tumors modified the biological parameters of tumor growth: in vitro it suppressed cell proliferation, reduced saturation density; and produced cellular pleomorphism. In vivo it increased tumor consistency by reducing central necrosis and increasing the viable cell layer thickness. Thus, 67 Ga deposition is closely related to various biological parameters of malignancy including the cellular membrane negative charge as cancer is a membrane disorder, and the lysosomal morphology and function. (author)

  11. Modeling of Energy Demand in the Greenhouse Using PSO-GA Hybrid Algorithms

    Directory of Open Access Journals (Sweden)

    Jiaoliao Chen

    2015-01-01

    Full Text Available Modeling of energy demand in agricultural greenhouse is very important to maintain optimum inside environment for plant growth and energy consumption decreasing. This paper deals with the identification parameters for physical model of energy demand in the greenhouse using hybrid particle swarm optimization and genetic algorithms technique (HPSO-GA. HPSO-GA is developed to estimate the indistinct internal parameters of greenhouse energy model, which is built based on thermal balance. Experiments were conducted to measure environment and energy parameters in a cooling greenhouse with surface water source heat pump system, which is located in mid-east China. System identification experiments identify model parameters using HPSO-GA such as inertias and heat transfer constants. The performance of HPSO-GA on the parameter estimation is better than GA and PSO. This algorithm can improve the classification accuracy while speeding up the convergence process and can avoid premature convergence. System identification results prove that HPSO-GA is reliable in solving parameter estimation problems for modeling the energy demand in the greenhouse.

  12. Compounds which mediate Gallium-67 transfer from lactoferrin to ferritin

    International Nuclear Information System (INIS)

    Weiner, R.E.; Schreiber, G.J.; Hoffer, P.B.; Bushberg, J.T.

    1985-01-01

    The influence of various low molecular weight compounds on the transfer of 67 Ga from human lactoferrin (LF) to horse spleen ferritin (HoFE) has been examined in vitro. When LF/sup */ 67 Ga complex was placed in competition with HoFE using a dialysis system the initial transfer rate (TR) of 67 Ga to HoFE was slow and continuous. In the presence of 1 mM pyrophosphate (PP/sub i/) ascorbate and adenosine triphosphate (ATP), the TR was dramatically enhanced. This effect was concentration sensitive since reduction of the ATP to 0.1 mM eliminated the enhancement. Although PP/sub i/ and ascorbate ions yielded larger TR's, ATP was more effective in the promotion of 67 Ga transfer to HoFE. When the LF/HoFE concentration ratio was decreased, in the presence of ATP, the transfer of 67 Ga was significantly increased. These results suggest that ferritin present intracellularly could remove and retain 67 Ga entering the cell in the form of a LF/sub */ 67 Ga complex. Moreover, increased synthesis of ferritin and cytosolic phosphate compounds would appear to enhance this process

  13. Hybrid GaN LED with capillary-bonded II–VI MQW color-converting membrane for visible light communications

    International Nuclear Information System (INIS)

    Santos, Joao M M; Jones, Brynmor E; Schlosser, Peter J; Herrnsdorf, Johannes; Guilhabert, Benoit; McKendry, Jonathan J D; Hastie, Jennifer E; Laurand, Nicolas; Dawson, Martin D; Watson, Scott; Kelly, Anthony E; De Jesus, Joel; Garcia, Thor A; Tamargo, Maria C

    2015-01-01

    The rapid emergence of gallium-nitride (GaN) light-emitting diodes (LEDs) for solid-state lighting has created a timely opportunity for optical communications using visible light. One important challenge to address this opportunity is to extend the wavelength coverage of GaN LEDs without compromising their modulation properties. Here, a hybrid source for emission at 540 nm consisting of a 450 nm GaN micro-sized LED (micro-LED) with a micron-thick ZnCdSe/ZnCdMgSe multi-quantum-well color-converting membrane is reported. The membrane is liquid-capillary-bonded directly onto the sapphire window of the micro-LED for full hybridization. At an injection current of 100 mA, the color-converted power was found to be 37 μW. At this same current, the −3 dB optical modulation bandwidth of the bare GaN and hybrid micro-LEDs were 79 and 51 MHz, respectively. The intrinsic bandwidth of the color-converting membrane was found to be power-density independent over the range of the micro-LED operation at 145 MHz, which corresponds to a mean carrier lifetime of 1.9 ns. (paper)

  14. SPECT/CT in pediatric patient management

    International Nuclear Information System (INIS)

    Nadel, Helen R.

    2014-01-01

    Hybrid SPECT/CT imaging is becoming the standard of care in pediatric imaging. Indications are mainly for oncologic imaging including mIBG scintigraphy for neuroblastoma and I-123 post surgical imaging of children with thyroid carcinoma, bone scintigraphy for back pain, children referred from sports medicine and neurodevelopmentally delayed children presenting with pain symptoms. The studies provide improved diagnostic accuracy, and oncologic imaging that includes optimized CT as part of the SPECT/CT study may decrease the number of studies and sedation procedures an individual child may need. The studies, however, must be tailored on an individual basis as the addition of the CT study can increase exposure to the child and should only be performed after appropriate justification and with adherence to optimized low dose pediatric protocols. (orig.)

  15. SPECT/CT in pediatric patient management

    Energy Technology Data Exchange (ETDEWEB)

    Nadel, Helen R. [British Columbia Children' s Hospital, University of British Columbia, Pediatric Radiologist and Nuclear Medicine Physician, Division of Nuclear Medicine Department of Radiology, Vancouver, British Columbia (Canada)

    2014-05-15

    Hybrid SPECT/CT imaging is becoming the standard of care in pediatric imaging. Indications are mainly for oncologic imaging including mIBG scintigraphy for neuroblastoma and I-123 post surgical imaging of children with thyroid carcinoma, bone scintigraphy for back pain, children referred from sports medicine and neurodevelopmentally delayed children presenting with pain symptoms. The studies provide improved diagnostic accuracy, and oncologic imaging that includes optimized CT as part of the SPECT/CT study may decrease the number of studies and sedation procedures an individual child may need. The studies, however, must be tailored on an individual basis as the addition of the CT study can increase exposure to the child and should only be performed after appropriate justification and with adherence to optimized low dose pediatric protocols. (orig.)

  16. The origins of SPECT and SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Hutton, Brian F. [University College London, Institute of Nuclear Medicine, London (United Kingdom); University of Wollongong, Centre for Medical Radiation Physics, Wollongong, NSW (Australia)

    2014-05-15

    Single photon emission computed tomography (SPECT) has a long history of development since its initial demonstration by Kuhl and Edwards in 1963. Although clinical utility has been dominated by the rotating gamma camera, there have been many technological innovations with the recent popularity of organ-specific dedicated SPECT systems. The combination of SPECT and CT evolved from early transmission techniques used for attenuation correction with the initial commercial systems predating the release of PET/CT. The development and acceptance of SPECT/CT has been relatively slow with continuing debate as to what cost/performance ratio is justified. Increasingly, fully diagnostic CT is combined with SPECT so as to facilitate optimal clinical utility. (orig.)

  17. Extraordinary Hall effect in Co implanted GaAs hybrid magnetic semiconductors

    International Nuclear Information System (INIS)

    Honda, S.; Tateishi, K.; Nawate, M.; Sakamoto, I.

    2004-01-01

    Hybrid Co/GaAs ferromagnetic semiconductors have been prepared by implantation method. In these samples, sheet resistance shows weak temperature dependence, and the extraordinary Hall effect with positive coefficient is observed. In small Co content samples, Hall resistance increases with decreasing temperature and maximum value of 3.6x10 -2 Ω is obtained at 150 K

  18. A Hybrid Readout Solution for GaN-Based Detectors Using CMOS Technology

    Directory of Open Access Journals (Sweden)

    Preethi Padmanabhan

    2018-02-01

    Full Text Available Gallium nitride (GaN and its alloys are becoming preferred materials for ultraviolet (UV detectors due to their wide bandgap and tailorable out-of-band cutoff from 3.4 eV to 6.2 eV. GaN based avalanche photodiodes (APDs are particularly suitable for their high photon sensitivity and quantum efficiency in the UV region and for their inherent insensitivity to visible wavelengths. Challenges exist however for practical utilization. With growing interests in such photodetectors, hybrid readout solutions are becoming prevalent with CMOS technology being adopted for its maturity, scalability, and reliability. In this paper, we describe our approach to combine GaN APDs with a CMOS readout circuit, comprising of a linear array of 1 × 8 capacitive transimpedance amplifiers (CTIAs, implemented in a 0.35 µm high voltage CMOS technology. Further, we present a simple, yet sustainable circuit technique to allow operation of APDs under high reverse biases, up to ≈80 V with verified measurement results. The readout offers a conversion gain of 0.43 µV/e−, obtaining avalanche gains up to 103. Several parameters of the CTIA are discussed followed by a perspective on possible hybridization, exploiting the advantages of a 3D-stacked technology.

  19. A Hybrid Readout Solution for GaN-Based Detectors Using CMOS Technology.

    Science.gov (United States)

    Padmanabhan, Preethi; Hancock, Bruce; Nikzad, Shouleh; Bell, L Douglas; Kroep, Kees; Charbon, Edoardo

    2018-02-03

    Gallium nitride (GaN) and its alloys are becoming preferred materials for ultraviolet (UV) detectors due to their wide bandgap and tailorable out-of-band cutoff from 3.4 eV to 6.2 eV. GaN based avalanche photodiodes (APDs) are particularly suitable for their high photon sensitivity and quantum efficiency in the UV region and for their inherent insensitivity to visible wavelengths. Challenges exist however for practical utilization. With growing interests in such photodetectors, hybrid readout solutions are becoming prevalent with CMOS technology being adopted for its maturity, scalability, and reliability. In this paper, we describe our approach to combine GaN APDs with a CMOS readout circuit, comprising of a linear array of 1 × 8 capacitive transimpedance amplifiers (CTIAs), implemented in a 0.35 µm high voltage CMOS technology. Further, we present a simple, yet sustainable circuit technique to allow operation of APDs under high reverse biases, up to ≈80 V with verified measurement results. The readout offers a conversion gain of 0.43 µV/e - , obtaining avalanche gains up to 10³. Several parameters of the CTIA are discussed followed by a perspective on possible hybridization, exploiting the advantages of a 3D-stacked technology.

  20. Interface and photoluminescence characteristics of graphene-(GaN/InGaN){sub n} multiple quantum wells hybrid structure

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Liancheng, E-mail: wanglc@semi.ac.cn, E-mail: lzq@semi.ac.cn, E-mail: zh.zhang@hebut.edu.cn [Engineering Product Development Pillar (EPD), Singapore University of Technology & Design (SUTD), 8 Somapah Road, Singapore 487372 (Singapore); Semiconductor Lighting Technology Research and Development Center, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083 (China); Mind Star (Beijing) Technology Co., Ltd., Zhongguancun South Street, Haidian District, No. 45 Hing Fat Building 1001, Beijing 100872 (China); Liu, Zhiqiang, E-mail: wanglc@semi.ac.cn, E-mail: lzq@semi.ac.cn, E-mail: zh.zhang@hebut.edu.cn; Tian, Ying Dong; Yi, Xiaoyan; Wang, Junxi; Li, Jinmin; Wang, Guohong [Semiconductor Lighting Technology Research and Development Center, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083 (China); Zhang, Zi-Hui, E-mail: wanglc@semi.ac.cn, E-mail: lzq@semi.ac.cn, E-mail: zh.zhang@hebut.edu.cn [Key Laboratory of Electronic Materials and Devices of Tianjin, School of Electronics and Information Engineering, Hebei University of Technology, Tianjin 300401 (China)

    2016-04-14

    The effects of graphene on the optical properties of active system, e.g., the InGaN/GaN multiple quantum wells, are thoroughly investigated and clarified. Here, we have investigated the mechanisms accounting for the photoluminescence reduction for the graphene covered GaN/InGaN multiple quantum wells hybrid structure. Compared to the bare multiple quantum wells, the photoluminescence intensity of graphene covered multiple quantum wells showed a 39% decrease after excluding the graphene absorption losses. The responsible mechanisms have been identified with the following factors: (1) the graphene two dimensional hole gas intensifies the polarization field in multiple quantum wells, thus steepening the quantum well band profile and causing hole-electron pairs to further separate; (2) a lower affinity of graphene compared to air leading to a weaker capability to confine the excited hot electrons in multiple quantum wells; and (3) exciton transfer through non-radiative energy transfer process. These factors are theoretically analysed based on advanced physical models of semiconductor devices calculations and experimentally verified by varying structural parameters, such as the indium fraction in multiple quantum wells and the thickness of the last GaN quantum barrier spacer layer.

  1. Software-based hybrid perfusion SPECT/CT provides diagnostic accuracy when other pulmonary embolism imaging is indeterminate

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Nishant; Xie, Karen; Mar, Winnie; Anderson, Thomas M.; Carney, Benjamin; Mehta, Nikhil; Machado, Roberto; Blend, Michael J.; Lu, Yang [University of Illinois Hospital and Health Sciences System, Chicago (Korea, Republic of)

    2015-12-15

    To investigate the diagnostic performance of perfusion single-photon emission computed tomography/computed tomography (Q-SPECT/CT) in patients suspected to have pulmonary embolism (PE) but with indeterminate computed tomographic pulmonary angiography (CTPA) or planar ventilation/perfusion (V/Q) scans. This retrospective study included two groups of patients. Group I consisted of 49 patients with nondiagnostic CTPA. These 49 patients underwent subsequent V/Q scans. Further Q-SPECTs were obtained in patients with indeterminate planar images and fused with existing CTPA. Group II consisted of 182 non-CTPA patients with indeterminate V/Q scans. These 182 patients underwent further Q-SPECT and separate noncontrast low-dose CT chest. Fusion Q-SPECT/CT scans were obtained through FDA-approved software and interpreted according to published criteria as positive, negative, or indeterminate for PE. Upon retrospective analyses, the final diagnosis was made using composite reference standards including all available clinical and imaging information for at least 6-month follow-up. In group I patients, 1 was positive, 24 were negative, and another 24 (49 %, 24/49) were indeterminate. In the subsequent 24 Q-SPECT/CTPAs, 4 were positive, 19 were negative, and 1 was indeterminate (4.2 %, 1/24). In group II patients, 9 (4.9 %, 9/182) were indeterminate, 33 were positive, and 140 were negative. The combined nondiagnostic rate for Q-SPECT/CT was only 4.9 % (10/206). There was six false-negative and one false-positive Q-SPECT/CT examinations. The sensitivity, specificity, and positive and negative predictive value of Q-SPECT/CT were 85.7 % (36/42), 99.4 % (153/154), 97.3 % (36/37) and 96.2 % (153/159), respectively. Q-SPECT/CT improves the diagnostic rate with promising accuracy in diagnosing PE that yields a satisfactory clinical verdict, especially when the CTPA and planar V/Q scan are indeterminate.

  2. Novel SPECT Technologies and Approaches in Cardiac Imaging

    Directory of Open Access Journals (Sweden)

    Piotr Slomka

    2016-12-01

    Full Text Available Recent novel approaches in myocardial perfusion single photon emission CT (SPECT have been facilitated by new dedicated high-efficiency hardware with solid-state detectors and optimized collimators. New protocols include very low-dose (1 mSv stress-only, two-position imaging to mitigate attenuation artifacts, and simultaneous dual-isotope imaging. Attenuation correction can be performed by specialized low-dose systems or by previously obtained CT coronary calcium scans. Hybrid protocols using CT angiography have been proposed. Image quality improvements have been demonstrated by novel reconstructions and motion correction. Fast SPECT acquisition facilitates dynamic flow and early function measurements. Image processing algorithms have become automated with virtually unsupervised extraction of quantitative imaging variables. This automation facilitates integration with clinical variables derived by machine learning to predict patient outcome or diagnosis. In this review, we describe new imaging protocols made possible by the new hardware developments. We also discuss several novel software approaches for the quantification and interpretation of myocardial perfusion SPECT scans.

  3. Complexity and accuracy of image registration methods in SPECT-guided radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yin, L S; Duzenli, C; Moiseenko, V [Physics and Astronomy, University of British Columbia, 6224 Agricultural Road, Vancouver, BC, V6T 1Z1 (Canada); Tang, L; Hamarneh, G [Computing Science, Simon Fraser University, 9400 TASC1, Burnaby, BC, V5A 1S6 (Canada); Gill, B [Medical Physics, Vancouver Cancer Centre, BC Cancer Agency, 600 West 10th Ave, Vancouver, BC, V5Z 4E6 (Canada); Celler, A; Shcherbinin, S [Department of Radiology, University of British Columbia, 828 West 10th Ave, Vancouver, BC, V5Z 1L8 (Canada); Fua, T F; Thompson, A; Sheehan, F [Radiation Oncology, Vancouver Cancer Centre, BC Cancer Agency, 600 West 10th Ave, Vancouver, BC, V5Z 4E6 (Canada); Liu, M [Radiation Oncology, Fraser Valley Cancer Centre, BC Cancer Agency, 13750 9th Ave, Surrey, BC, V3V 1Z2 (Canada)], E-mail: lyin@bccancer.bc.ca

    2010-01-07

    The use of functional imaging in radiotherapy treatment (RT) planning requires accurate co-registration of functional imaging scans to CT scans. We evaluated six methods of image registration for use in SPECT-guided radiotherapy treatment planning. Methods varied in complexity from 3D affine transform based on control points to diffeomorphic demons and level set non-rigid registration. Ten lung cancer patients underwent perfusion SPECT-scans prior to their radiotherapy. CT images from a hybrid SPECT/CT scanner were registered to a planning CT, and then the same transformation was applied to the SPECT images. According to registration evaluation measures computed based on the intensity difference between the registered CT images or based on target registration error, non-rigid registrations provided a higher degree of accuracy than rigid methods. However, due to the irregularities in some of the obtained deformation fields, warping the SPECT using these fields may result in unacceptable changes to the SPECT intensity distribution that would preclude use in RT planning. Moreover, the differences between intensity histograms in the original and registered SPECT image sets were the largest for diffeomorphic demons and level set methods. In conclusion, the use of intensity-based validation measures alone is not sufficient for SPECT/CT registration for RTTP. It was also found that the proper evaluation of image registration requires the use of several accuracy metrics.

  4. New production cross sections for the theranostic radionuclide 67Cu

    Science.gov (United States)

    Pupillo, Gaia; Sounalet, Thomas; Michel, Nathalie; Mou, Liliana; Esposito, Juan; Haddad, Férid

    2018-01-01

    The cross sections of the 68Zn(p,2p)67Cu, 68Zn(p,2n)67Ga and 68Zn(p,3n)66Ga reactions were measured at the ARRONAX facility by using the 70 MeV cyclotron, with particular attention to the production of the theranostic radionuclide 67Cu. Enriched 68Zn material was electroplated on silver backing and exposed to a low-intensity proton beam by using the stacked-foils target method. Since 67Cu and 67Ga radionuclides have similar half-lives and same γ-lines (they both decay to 67Zn), a radiochemical process aimed at Cu/Ga separation was mandatory to avoid interferences in γ-spectrometry measurements. A simple chemical procedure having a high separation efficiency (>99%) was developed and monitored during each foil processing, thanks to the tracer isotopes 61Cu and 66Ga. Nuclear cross sections were measured in the energy range 35-70 MeV by using reference reactions recommended by the International Atomic Energy Agency (IAEA) to monitor beam flux. In comparison with literature data a general good agreement on the trend of the nuclear reactions was noted, especially with latest measurements, but slightly lower values were obtained in case of 67Cu. Experimental results of the 68Zn(p,2p)67Cu, 68Zn(p,2n)67Ga and 68Zn(p,3n)66Ga reactions were also compared with the theoretical values estimated by using the software TALYS. The production yield of the theranostic radionuclide 67Cu was estimated considering the results obtained in this work.

  5. SPECT/CT imaging in general orthopedic practice.

    Science.gov (United States)

    Scharf, Stephen

    2009-09-01

    The availability of hybrid devices that combine the latest single-photon emission computed tomography (SPECT) imaging technology with multislice computed tomography (CT) scanning has allowed us to detect subtle, nonspecific abnormalities on bone scans and interpret them as specific focal areas of pathology. Abnormalities in the spine can be separated into those caused by pars fractures, facet joint arthritis, or osteophyte formation on vertebral bodies. Compression fractures can be distinguished from severe degenerative disease, both of which can cause intense activity across the spine on either planar or SPECT imaging. Localizing activity in patients who have had spinal fusion can provide tremendous insight into the causes of therapeutic failures. Infections of the spine now can be diagnosed with gallium SPECT/CT, despite the fact that gallium has long been abandoned because of its failure to detect spine infection on either planar or SPECT imaging. Small focal abnormalities in the feet and ankles can be localized well enough to make specific orthopedic diagnoses on the basis of their location. Moreover, when radiographic imaging provides equivocal or inadequate information, SPECT/CT can provide a road map for further diagnostic studies and has been invaluable in planning surgery. Our ability to localize activity within a bone or at an articular surface has allowed us to distinguish between fractures and joint disease. Increased activity associated with congenital anomalies, such as tarsal coalition and Bertolotti's syndrome have allowed us to understand the pathophysiology of these conditions, to confirm them as the cause of the patient's symptoms, and to provide information that is useful in determining appropriate clinical management. As our experience broadens, SPECT/CT will undoubtedly become an important tool in the evaluation and management of a wider variety of orthopedic patients.

  6. SPECT/CT: main applications in nuclear medicine

    International Nuclear Information System (INIS)

    Perera Pintado, Alejandro; Torres Aroche, Leonel A.; Vergara Gil, Alex; Batista Cuéllar, Juan F.; Prats Capote, Anaís

    2017-01-01

    SPECT/CT has represented not only the possibility of acquiring anatomical and functional images in one single study, but also a revolution for the clinical management of several diseases, taking the better of each one of these imaging modalities. The present work is aimed at presenting an overview of the most important applications of the SPECT/CT in the field of oncology, cardiology and neurology. New technological advances in the design of innovative solid state detectors and related equipment have had a positive effect on the performance of this kind of dual modality. This hybrid technique improves the sensitivity and the specificity of gammagraphic studies, as well as shortens the acquisition times and gives attenuation correction of co-registered images, which, in turn, makes their analysis easier. Some of the main applications for the study of oncological diseases are the following: localization and follow-up of different kinds of tumors, their metastasis and relapses, as well as the optimization of radiotherapy doses. This technique has been useful to evaluate the coronary artery disease allowing an adequate attenuation correction of images, the determination of calcium score, and performing angio-CT studies, according to the CT quality. SPECT/CT has also gained ground in the assessment of some neurological diseases. Conclusions: The introduction of new technological advances and radiopharmaceuticals thus predicting a more relevant place for SPECT/CT in clinical practice. (author)

  7. 111In-DOTA-dPhe1-Tyr3-octreotide, 111In-DOTA-lanreotide and 67Ga citrate scintigraphy for visualisation of extranodal marginal zone B-cell lymphoma of the MALT type: a comparative study

    International Nuclear Information System (INIS)

    Li, Shuren; Kurtaran, Amir; Li, Mei; Traub-Weidinger, Tatjana; Kienast, Oskar; Schima, Wolfgang; Angelberger, Peter; Virgolini, Irene; Raderer, Markus; Dudczak, Robert

    2003-01-01

    Somatostatin receptor (SSTR) scintigraphy and gallium-67 citrate ( 67 Ga) scintigraphy have been used for visualisation of Hodgkin's lymphoma and non-Hodgkin's lymphoma. However, experience with B-cell lymphoma of the mucosa-associated lymphoid tissue (MALT) type is very limited. The aim of this study was to prospectively compare the 67 Ga scintigraphy results with those obtained by 111 In-DOTA-dPhe 1 -Tyr 3 -octreotide ( 111 In-DOTA-TOCT) and 111 In-DOTA-lanreotide ( 111 In-DOTA-LAN) scintigraphy in patients with proven MALT-type lymphoma. Comparative scintigraphic examinations using 67 Ga, 111 In-DOTA-TOCT and 111 In-DOTA-LAN were performed in 18 patients (11 female and 7 male, median age 64±15 years) with histologically verified MALT-type lymphomas of various origin. Planar and single-photon emission tomography imaging acquisitions were performed after injection of a mean dose of 185±26 MBq 67 Ga and 165±20 MBq 111 In-DOTA-TOCT or 111 In-DOTA-LAN. All scintigraphic results were correlated with other conventional examinations including gastroscopy, colonoscopy, endosonoscopy, ophthalmologic investigation, CT of the thorax and abdomen and bone marrow biopsy. This comparative study showed that 67 Ga scintigraphy found abnormalities in 10 of 16 patients (63%) and detected 18 of 31 clinically involved sites (58%), but was false positive in three patients. 111 In-DOTA-TOCT found abnormalities in 9 of 15 patients (60%) and detected 15 of 27 clinical lesions (56%); it was false positive in two patients. 111 In-DOTA-LAN scintigraphy showed abnormalities in 7 of 11 patients (64%) and found 12 of 22 clinical lesions (55%). False-positive 111 In-DOTA-LAN scan results were found in two patients. For supra-diaphragmatic lesions, 67 Ga scintigraphy detected 12 of 16 sites (75%). 111 In-DOTA-TOCT scintigraphy revealed 7 of 15 lesions (47%). 111 In-DOTA-LAN showed 6 of 12 positive sites (50%). For infra-diaphragmatic involvement, the sensitivities of 67 Ga, 111 In

  8. Performance of 3DOSEM and MAP algorithms for reconstructing low count SPECT acquisitions

    Energy Technology Data Exchange (ETDEWEB)

    Grootjans, Willem [Radboud Univ. Medical Center, Nijmegen (Netherlands). Dept. of Radiology and Nuclear Medicine; Leiden Univ. Medical Center (Netherlands). Dept. of Radiology; Meeuwis, Antoi P.W.; Gotthardt, Martin; Visser, Eric P. [Radboud Univ. Medical Center, Nijmegen (Netherlands). Dept. of Radiology and Nuclear Medicine; Slump, Cornelis H. [Univ. Twente, Enschede (Netherlands). MIRA Inst. for Biomedical Technology and Technical Medicine; Geus-Oei, Lioe-Fee de [Radboud Univ. Medical Center, Nijmegen (Netherlands). Dept. of Radiology and Nuclear Medicine; Univ. Twente, Enschede (Netherlands). MIRA Inst. for Biomedical Technology and Technical Medicine; Leiden Univ. Medical Center (Netherlands). Dept. of Radiology

    2016-07-01

    Low count single photon emission computed tomography (SPECT) is becoming more important in view of whole body SPECT and reduction of radiation dose. In this study, we investigated the performance of several 3D ordered subset expectation maximization (3DOSEM) and maximum a posteriori (MAP) algorithms for reconstructing low count SPECT images. Phantom experiments were conducted using the National Electrical Manufacturers Association (NEMA) NU2 image quality (IQ) phantom. The background compartment of the phantom was filled with varying concentrations of pertechnetate and indiumchloride, simulating various clinical imaging conditions. Images were acquired using a hybrid SPECT/CT scanner and reconstructed with 3DOSEM and MAP reconstruction algorithms implemented in Siemens Syngo MI.SPECT (Flash3D) and Hermes Hybrid Recon Oncology (Hyrid Recon 3DOSEM and MAP). Image analysis was performed by calculating the contrast recovery coefficient (CRC),percentage background variability (N%), and contrast-to-noise ratio (CNR), defined as the ratio between CRC and N%. Furthermore, image distortion is characterized by calculating the aspect ratio (AR) of ellipses fitted to the hot spheres. Additionally, the performance of these algorithms to reconstruct clinical images was investigated. Images reconstructed with 3DOSEM algorithms demonstrated superior image quality in terms of contrast and resolution recovery when compared to images reconstructed with filtered-back-projection (FBP), OSEM and 2DOSEM. However, occurrence of correlated noise patterns and image distortions significantly deteriorated the quality of 3DOSEM reconstructed images. The mean AR for the 37, 28, 22, and 17 mm spheres was 1.3, 1.3, 1.6, and 1.7 respectively. The mean N% increase in high and low count Flash3D and Hybrid Recon 3DOSEM from 5.9% and 4.0% to 11.1% and 9.0%, respectively. Similarly, the mean CNR decreased in high and low count Flash3D and Hybrid Recon 3DOSEM from 8.7 and 8.8 to 3.6 and 4

  9. Gastric gallium-67 uptake in gastritis

    International Nuclear Information System (INIS)

    Yeh, E.L.; Tisdale, P.L.; Zielonka, J.S.

    1983-01-01

    Even though Ga-67 imaging has been used widely in the diagnosis of malignant as well as inflammatory lesions, its uptake in the stomach has been reported in the literature mainly in gastric lymphoma and carcinoma. As shown in this case, intense gastric uptake of the radionuclide may be seen in common gastritis without malignancy. Perhaps the benign gastric uptake of Ga-67 deserves more emphasis

  10. Development of method to chemical separation of gallium-67 by thermal diffusion technique; Desenvolvimento de metodo para separacao quimica de galio-67 pela tecnica de difusao termica

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Patricia de Andrade

    2012-07-01

    Radioisotopes of gallium have been studied and evaluated for medical applications since 1949. Over the past 50 years {sup 67}Ga has been widely used in the diagnosis of various diseases, including acute and chronic inflammatory lesions, bacterial or sterile and several types of tumors. In Brazil 30% of clinics that provide services for Nuclear Medicine use {sup 67}Ga citrate and the demand for 67{sup G}a at IPEN-CNEN/SP is 37 GBq (1 Ci)/week. The {sup 67}Ga presents physical half-life of 3.26 days (78 hours) and decays 100% by electron capture to stable {sup 67}Zn. Its decay includes the emission of {gamma} rays with energies of 93.3 keV (37%), 184.6 keV (20.4%), 300.2 keV (16.6%) and 888 keV (26%). In the past {sup 67}Ga was produced by the reaction {sup 68}Zn (p, 2n) {sup 67}Ga at IPEN-CNEN/SP. After irradiation, the target was dissolved in concentrated HCl and the solution percolated through a cationic resin DOWEX 50W-X8, 200-400 mesh, conditioned with 10 mol L{sup -1} HCl. Zinc, nickel and copper were eluted in 10 mol L{sup -1} HCl and {sup 67}Ga 3.5 mol L{sup -1} HCl. The final product was obtained as {sup 67}Ga citrate. This work presents a new, fast, direct and efficient method for the chemical separation of 67{sup G}a by thermal diffusion (heating of the target) combined with concentrated acetic acid extraction. Purification was performed by ion exchange chromatography. Natural zinc electrodeposition was performed on nickel/copper plates as substrate and the zinc deposits were adherent to the substrate, slightly shiny and uniform. The targets were irradiated with 26 MeV protons and integrated current of 10 {mu}A.h. After irradiation, the targets were heated at 300 deg C for 2 hours and placed in contact with concentrated acetic acid for 1 hour. The average yield of extraction of {sup 67}Ga was (72 {+-} 10)%. This solution was evaporated and the residue was taken up in 0.5 mol L{sup -1} NH{sub 4}OH. The 67{sup G}a was purified on cationic resin Dowex 50WX8

  11. A Hybrid Readout Solution for GaN-Based Detectors Using CMOS Technology †

    Science.gov (United States)

    Hancock, Bruce; Nikzad, Shouleh; Bell, L. Douglas; Kroep, Kees; Charbon, Edoardo

    2018-01-01

    Gallium nitride (GaN) and its alloys are becoming preferred materials for ultraviolet (UV) detectors due to their wide bandgap and tailorable out-of-band cutoff from 3.4 eV to 6.2 eV. GaN based avalanche photodiodes (APDs) are particularly suitable for their high photon sensitivity and quantum efficiency in the UV region and for their inherent insensitivity to visible wavelengths. Challenges exist however for practical utilization. With growing interests in such photodetectors, hybrid readout solutions are becoming prevalent with CMOS technology being adopted for its maturity, scalability, and reliability. In this paper, we describe our approach to combine GaN APDs with a CMOS readout circuit, comprising of a linear array of 1 × 8 capacitive transimpedance amplifiers (CTIAs), implemented in a 0.35 µm high voltage CMOS technology. Further, we present a simple, yet sustainable circuit technique to allow operation of APDs under high reverse biases, up to ≈80 V with verified measurement results. The readout offers a conversion gain of 0.43 µV/e−, obtaining avalanche gains up to 103. Several parameters of the CTIA are discussed followed by a perspective on possible hybridization, exploiting the advantages of a 3D-stacked technology. PMID:29401655

  12. White light generation using CdSe/ZnS core-shell nanocrystals hybridized with InGaN/GaN light emitting diodes

    International Nuclear Information System (INIS)

    Nizamoglu, S; Ozel, T; Sari, E; Demir, H V

    2007-01-01

    We introduce white light generation using CdSe/ZnS core-shell nanocrystals of single, dual, triple and quadruple combinations hybridized with InGaN/GaN LEDs. Such hybridization of different nanocrystal combinations provides the ability to conveniently adjust white light parameters including the tristimulus coordinates (x,y), correlated colour temperature (T c ) and colour rending index (R a ). We present the design, growth, fabrication and characterization of our white hybrid nanocrystal-LEDs that incorporate combinations of (1) yellow nanocrystals (λ PL = 580 nm) on a blue LED (λ EL = 440 nm) with (x,y) = (0.37,0.25), T c = 2692 K and R a 14.69; (2) cyan and red nanocrystals (λ PL = 500 and 620 nm) on a blue LED (λ EL = 440 nm) with (x,y) = (0.37,0.28), T c = 3246 K and R a = 19.65; (3) green, yellow and red nanocrystals (λ PL = 540, 580 and 620 nm) on a blue LED (λ EL = 452 nm) with (x,y) = (0.30,0.28), T c = 7521 K and R a = 40.95; and (4) cyan, green, yellow and red nanocrystals (λ PL = 500, 540, 580 and 620 nm) on a blue LED (λ EL = 452 nm) with (x,y) = (0.24,0.33), T c = 11 171 K and R a 71.07. These hybrid white light sources hold promise for future lighting and display applications with their highly adjustable properties

  13. Intense muscle uptake of Ga-67 citrate and Tc-99m MDP in a patient with aplastic anemia

    International Nuclear Information System (INIS)

    Batte, W.G. Jr.; Yeh, S.D.; Rosenblum, M.K.; Larson, S.M.

    1991-01-01

    An unusual distribution of Tc-99m MDP and Ga-67 citrate in several muscle groups is described in a 14-year-old boy with aplastic anemia and normal renal function at the time of imaging. Although the patient did not develop musculo-skeletal signs or symptoms, a subsequent autopsy revealed widespread muscle calcification

  14. Sorption of trace amounts of 67Ga and 65Zn on some divalent and trivalent metal hydroxides

    International Nuclear Information System (INIS)

    Music, S.; Sipalo-Zuljevic, J.; Vlatkovic, M.

    1977-01-01

    Trace concentrations of 67 Ga and 65 Zn were applied to the radiochemical study of sorption using Al(III), Cr(III), Fe(III), In(III), La(III), Zn(II), Cu(II) and Ni(II) hydroxides as sorbents. The results are given in terms of percentages sorbed, depending on solution pH or on the time of contact between the heterofeneous phases. The percentage sorbed is strongly pH-dependent. Sorption curves for 67 Ga show the maximum sorption (about 100%) starting from the pH values at the onset of the sorbent precipitation and ending with their approximate isoelectric point. Further increase in pH leads to a sudden decrease of the amounts sorbed. The sorption of 65 Zn is also pH-dependent; the decrease of sorption proceeds from right-to-left on the pH scale, i.e. in reverse direction if compared with gallium. The results are explained in terms of coprecipitation, electrostatic attraction (repulsion) and Van der Waals induced dipole attraction. Some sorption results, concerning the contact time dependence of the sorption are discussed in terms of specific sorption controlled by the diffusion of sorbate into the solid sorbent. (author)

  15. Myocardial Perfusion SPECT 2015 in Germany

    Science.gov (United States)

    Burchert, Wolfgang; Schäfer, Wolfgang; Hacker, Marcus

    2016-01-01

    Summary Aim The working group Cardiovascular Nuclear Medicine of the German Society of Nuclear Medicine presents the results of the 7th survey of myocardial perfusion SPECT (MPS) of the reporting year 2015. Method 268 questionnaires (173 practices [PR], 67 hospitals [HO], 28 university hospitals [UH]) were evaluated. Results of the last survey from 2012 are set in squared brackets. Results MPS of 121 939 [105 941] patients were reported. 98 % [95 %] of all MPS were performed with Tc-99m radiopharmaceuticals and 2 % [5 %] with Tl-201. 78 % [79 %] of all patients were studied in PR, 14 % [15 %] in HO, and 8 % [6 %] in UH. A pharmacological stress test was performed in 43 % [39 %] (22 % [24 %] adenosine, 20 % [9 %] regadenoson, 1% [6 %] dipyridamole or dobutamine). Attenuation correction was applied in 25 % [2009: 10 %] of MPS. Gated SPECT was performed in 78 % [70 %] of all rest MPS, in 80 % [73 %] of all stress and in 76 % [67 %] of all stress and rest MPS. 53 % [33 %] of all nuclear medicine departments performed MPS scoring by default, whereas 24 % [41 %] did not apply any quantification. 31 % [26 %] of all departments noticed an increase in their counted MPS and 29 % [29 %] no changes. Data from 89 departments which participated in all surveys showed an increase in MPS count of 11.1 % (PR: 12.2 %, HO: 4.8 %, UH: 18.4 %). 70 % [60 %] of the MPS were requested by ambulatory care cardiologists. Conclusion The 2015 MPS survey reveals a high-grade adherence of routine MPS practice to current guidelines. The positive trend in MPS performance and number of MPS already observed in 2012 continues. Educational training remains necessary in the field of SPECT scoring. PMID:27909712

  16. Brain SPECT

    International Nuclear Information System (INIS)

    Feistel, H.

    1991-01-01

    Brain SPECT investigations have gained broad acceptance since the introduction of the lipophilic tracer Tc-99m-HMPAO. Depending on equipment and objectives in different departments, the examinations can be divided into three groups: 1. Under normal conditions and standardised patient preparation the 'rest' SPECT can be performed in every department with a tomographic camera. In cerebrovascular disease there is a demand for determination of either the perfusion reserve in reversible ischemia or prognostic values in completed stroke. In cases of dementia, SPECT may yield useful results according to differential diagnosis. Central cerebral system involvement in immunologic disease may be estimated with higher sensitivity than in conventional brain imaging procedures. In psychiatric diseases there is only a relative indication for brain SPECT, since results during recent years have been contradictory and may be derived only in interventional manner. In brain tumor diagnostics SPECT with Tl-201 possibly permits grading. In inflammatory disease, especially in viral encephalitis, SPECT may be used to obtain early diagnosis. Normal pressure hydrocephalus can be distinguished from other forms of dementia and, consequently, the necessity for shunting surgery can be recognised. 2. In departments equipped for emergency cases an 'acute' SPECT can be performed in illnesses with rapid changing symptoms such as different forms of migraine, transient global amnesia, epileptic seizures (so-called 'ictal SPECT') or urgent forms like trauma. 3. In cooperation with several departments brain SPECT can be practised as an interventional procedure in clinical and in scientific studies. (orig./MG) [de

  17. Diagnosis of abdominal abscesses with 67gallium

    International Nuclear Information System (INIS)

    Noguera, E.C.; Mothe, G.A.

    1987-01-01

    Twenty six patients were studied with 67 Gallium to detect and localize the site of intra-abdominal and intraperitoneal infection. They were divided in two groups: a) with and b) without physical symptoms that could localize an abcess in the abdominal cavity. All the patients with suppuration had persistent up-take of 67 Ga in one anatomic area of the abdomen, subsequently documented by computarized axial tomography (CAT) in 58% of the cases or by laparotomy in 88% of them. Scintigraphy with 67 Ga in the patients with recent surgery not only detected focal infection in 67% of the cases but excluded subphernic collection. In 78% of patients with prolonged fever, the infection was localized. There was no false positive result. The comparison in 56% of the cases with CAT demonstrated that both techniques are 100% sensitive for the diagnosis of abdominal suppurative processes. Three of the 26 patients, after six weeks of medical treatment, were restudied with 67 Ga and CAT, showing total resolution of their previous abnormalities. It is concluded that 67 Ga scintigraphy performed as the first study in febrile patients independent of the presence or absence of physical symptoms that could localize the abdominal infection, is sensitive for the detection and localization of an abdominal abscess and that a negative result excludes it. (Author) [es

  18. Localization of Hidden Insulinomas with ⁶⁸Ga-DOTA-Exendin-4 PET/CT: A Pilot Study.

    Science.gov (United States)

    Antwi, Kwadwo; Fani, Melpomeni; Nicolas, Guillaume; Rottenburger, Christof; Heye, Tobias; Reubi, Jean Claude; Gloor, Beat; Christ, Emanuel; Wild, Damian

    2015-07-01

    (111)In-DOTA-exendin-4 SPECT/CT has been shown to be highly efficient in the detection of insulinomas. We aimed at determining whether novel PET/CT imaging with [Nle(14),Lys(40)(Ahx-DOTA-(68)Ga)NH2]exendin-4 ((68)Ga-DOTA-exendin-4) is feasible and sensitive in detecting benign insulinomas. (68)Ga-DOTA-exendin-4 PET/CT and (111)In-DOTA-exendin-4 SPECT/CT were performed in a randomized cross-over order on 5 patients with endogenous hyperinsulinemic hypoglycemia. The gold standard for comparison was the histologic diagnosis after surgery. In 4 patients histologic diagnosis confirmed a benign insulinoma, whereas one patient refused surgery despite a positive (68)Ga-DOTA-exendin-4 PET/CT scan. In 4 of 5 patients, previously performed conventional imaging (CT or MR imaging) was not able to localize the insulinoma. (68)Ga-DOTA-exendin-4 PET/CT correctly identified the insulinoma in 4 of 4 patients, whereas (111)In-DOTA-exendin-4 SPECT/CT correctly identified the insulinoma in only 2 of 4 patients. These preliminary data suggest that the use of (68)Ga-DOTA-exendin-4 PET/CT in detecting hidden insulinomas is feasible. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  19. Gallium-67 scanning in patients with malignant pleural mesothelioma

    International Nuclear Information System (INIS)

    Nakano, Takashi; Maeda, Juichiro; Iwahashi, Noriaki; Tamura, Shinsuke; Hada, Toshikazu; Higashino, Kazuya

    1990-01-01

    The findings of gallium-67 scans in eleven patients with malignant pleural mesothelioma were reviewed and compared to those of chest CT findings. All patients had an abnormal thoracic Ga-67 accumulation. Six out of 11 showed a diffuse accumulation over the entire involved hemithorax and a localized uptake was shown in 5. A marked diffuse thickening of pleura in the absence of adequate gallium accumulation was observed in one patient. Two out of 11 had a reduction of gallium uptake after having combination chemotherapy. These results suggest that a diffusely increased uptake over the entire involved hemithorax is the most characteristic finding of Ga-67 scan in malignant pleural mesothelioma, and that Ga-67 scans may be helpful as a valuable indicator of the proper therapy. However, the superiority of Ga-67 scan to thoracic CT as a means of determining the extent of disease process could not be verified. (author)

  20. Gallium-67 imaging in patients with dilated cardiomyopathy and biopsy-proven myocarditis

    International Nuclear Information System (INIS)

    O'Connell, J.B.; Henkin, R.E.; Robinson, J.A.; Subramanian, R.; Scanlon, P.J.; Gunnar, R.M.

    1984-01-01

    Current standards for detection of myocarditis in a clinical setting rely on endomyocardial biopsy for accurate diagnosis. With this technique a subset of patients with dilated cardiomyopathy show unsuspected myocarditis histologically. Endomyocardial biopsy, despite its specificity, may lack sensitivity due to sampling error if the inflammation is patchy or focal. Therefore, inflammation-sensitive radioisotopic imaging may be a useful adjunct in the diagnosis of myocarditis. This study was designed to evaluate the applicability of gallium-67 (67Ga) myocardial imaging as an adjunct to endomyocardial biopsy in the diagnosis of myocarditis. Sixty-eight consecutive patients referred for evaluation of dilated cardiomyopathy underwent 71 parallel studies with 67Ga imaging and biopsies that served as the basis of comparison for this study. Histologic myocarditis was identified in 8% of biopsy specimens. Clinical and hemodynamic parameters could not be used to predict the presence of myocarditis. Five of six biopsy samples (87%) with myocarditis showed dense 67Ga uptake, whereas only nine of 65 negative biopsy samples (14%) were paired with equivocally positive 67Ga scans. The single patient with myocarditis and no myocardial 67Ga uptake had dense mediastinal lymph node uptake that may have obscured cardiac uptake. The incidence of myocarditis on biopsy with a positive 67Ga scan was 36% (5/14); however, the incidence of myocarditis with a negative 67Ga scan was only 1.8% (1/57). Follow-up scans for three patients showed close correlation of 67Ga uptake with myocarditis on biopsy. In conclusion 67Ga may be a useful screening test for identifying patients with a high yield of myocarditis on biopsy, and serial scans may eliminate the need for frequent biopsies in patients with proven myocarditis

  1. The validation and the limits of SPECT for patients suffering from cerebrovascular accidents

    International Nuclear Information System (INIS)

    Mizukawa, Norihiko; Yano, Ichiro; Tenjin, Hiroshi

    1989-01-01

    Contemporaneous single photon emission computed tomography (SPECT) and positron emission tomography (PET) were performed in 10 patients with cerebrovascular accidents (CVA), whose ages ranged from 11 to 67 years. I-123-isopropyl-iodoamphetamine (IMP) and/or Tc-99m hexamethylpropyleneamine oxime (HM-PAO) were used for SPECT. Cerebral blood flow (CBF), oxygen extraction fraction (OEF), and cerebral metabolic rate for oxygen (CMRO 2 ) were measured by an O-15 labelled gas continuous-inhalation method. SPECT images were quite similar to CBF and CMRO 2 during the chronic stage of CVA. Two patietns with vasospasm during the subacute stage had apparently low CBF and CMRO 2 on PET, but did not have low perfusion on SPECT. Luxury perfusion areas were detected in 4 subacute stage patients and one chronic stage patient. A redistribution of IMP was detected in two patients with infarction during subacute stage. CMRO 2 value in such an area was 2.0 ml/100 g/min. Low CBF and/or CMRO 2 areas were well visualized by IMP rather than by HM-PAO SPECT. (N.K.)

  2. Altered biodistribution of gallium-67 in a patient with multiple factors influencing iron-transport protein saturation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jeon Young; Kim, Sang Eun; Lee, Kyung Han; Kim, Byung Tae [College of Medicine, Samsung Medical Center, Seoul (Korea, Republic of)

    1998-01-01

    We present a case of a young female patient with fulminant hepatitis who showed an altered biodistribution of Ga-67, after being scanned twice at 10 month intervals. On initial scan, uptake of Ga-67 was increased in the liver, kidneys, and skeletons. Increased hepatic Ga-67 uptake may be explained by increased transferrin unbound Ga-67 that was taken up by the inflamed liver. The saturation of iron-binding proteins due to multiple transfusions may lead to increased renal and skeletal Ga-67 uptake. On follow-up scan hepatic Ga-67 uptake was markedly increased. Also increased Ga-67 uptake in the axial skeleton and normalized renal uptake were shown. The findings were consistent with iron deficiency anemia. This case demonstrates altered Ga-67 biodistribution associated with multiple transfusions, fulminant hepatitis, and iron deficiency anemia.

  3. Prospects for the application of GaN power devices in hybrid electric vehicle drive systems

    Science.gov (United States)

    Su, Ming; Chen, Chingchi; Rajan, Siddharth

    2013-07-01

    GaN, a wide bandgap semiconductor successfully implemented in optical and high-speed electronic devices, has gained momentum in recent years for power electronics applications. Along with rapid progress in material and device processing technologies, high-voltage transistors over 600 V have been reported by a number of teams worldwide. These advances make GaN highly attractive for the growing market of electrified vehicles, which currently employ bipolar silicon devices in the 600-1200 V class for the traction inverter. However, to capture this billion-dollar power market, GaN has to compete with existing IGBT products and deliver higher performance at comparable or lower cost. This paper reviews key achievements made by the GaN semiconductor industry, requirements of the automotive electric drive system and remaining challenges for GaN power devices to fit in the inverter application of hybrid vehicles.

  4. Utility of 67Ga scintigraphy and bronchial washings in the diagnosis and treatment of Pneumocystis carinii pneumonia in patients with the acquired immune deficiency syndrome

    International Nuclear Information System (INIS)

    Tuazon, C.U.; Delaney, M.D.; Simon, G.L.; Witorsch, P.; Varma, V.M.

    1985-01-01

    Twenty patients with the acquired immune deficiency syndrome (AIDS) and suspected Pneumocystis carinii pneumonia were evaluated by 67 Ga scintigraphy and fiberoptic bronchoscopy for initial diagnosis and response to therapy. Lung uptake of 67 Ga was demonstrated in 100% of AIDS patients with P. carinii pneumonia, including those with subclinical infection. Fiberoptic bronchoscopy identified P. carinii in the bronchial washings of 100% of cases (19 patients), whereas only 13 of 16 (81%) patients had P. carinii in lung tissue obtained by transbronchial biopsy. Repeat fiberoptic bronchoscopy was performed in 16 of 20 patients. After 2 to 4 wk of therapy, P. carinii was identified in bronchial washings in 8 of 16 (50%) patients and in transbronchial biopsy in 1 of 10 (10%) patients examined. Bronchial washing has a higher yield than transbronchial biopsy in demonstrating P. carinii in patients with AIDS and may evolve as the procedure of choice in such patients. Based on the clinical course and results of 67 Ga scintigraphy and fiberoptic bronchoscopy in AIDS patients with P. carinii pneumonia, optimal therapy may require at least 3 wk of treatment

  5. Diagnostic pathway of integrated SPECT/CT for coronary artery disease

    International Nuclear Information System (INIS)

    Slart, Riemer H.J.A.; Tio, Rene A.; Zijlstra, Felix; Dierckx, Rudi A.

    2009-01-01

    . The development of SPECT/CT hybrid systems is therefore of important value for the nuclear cardiology armamentarium. This editorial commentary outlines a diagnostic pathway of integrated SPECT/CT for CAD assessment in symptomatic patients at intermediate risk for CAD. (orig.)

  6. Tuning the magnetic properties of GaAs:Mn/MnAs hybrids via the MnAs cluster shape

    International Nuclear Information System (INIS)

    Nidda, H-A Krug von; Kurz, T; Loidl, A; Hartmann, Th; Klar, P J; Heimbrodt, W; Lampalzer, M; Volz, K; Stolz, W

    2006-01-01

    We report a systematic study of ferromagnetic resonance in granular GaAs:Mn/MnAs hybrids grown on GaAs(001) substrates by metal-organic vapour-phase epitaxy. The ferromagnetic resonance of the MnAs clusters can be resolved at all temperatures below T c . An additional broad absorption is observed below 60 K and is ascribed to localized charge carriers of the GaAs:Mn matrix. The anisotropy of the MnAs ferromagnetic resonance field originates from the magneto-crystalline field and demagnetization effects of the ferromagnetic MnAs clusters embedded in the GaAs:Mn matrix. Its temperature dependence basically scales with magnetization. Comparison of the observed angular dependence of the resonance field with model calculations yields the preferential orientation and shape of the clusters formed in hybrid layers of different thickness (150-1000 nm) grown otherwise at the same growth conditions. The hexagonal axes of the MnAs clusters are oriented along the four cubic GaAs space diagonals. Thin layers contain lens-shaped MnAs clusters close to the surface, whereas thick layers also contain spherical clusters in the bulk of the layer. The magnetic properties of the hexagonal MnAs clusters can be tuned by a controlled variation of the cluster shape

  7. Effect of bypass on the motor activation SPECT compared to the acetazolamide SPECT

    International Nuclear Information System (INIS)

    Kawaguchi, Shoichiro; Iwahashi, Hideaki; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime

    2002-01-01

    The authors evaluated and analyzed motor activation single photon emission computed tomography (M-SPECT) in ischemic cerebrovascular disease compared to resting and acetazolamide (ACZ) activated SPECT studies. Seventeen cases with STA-MCA bypass performed for ischemic cerebrovascular disease were examined. The SPECT studies consisting of resting, ACZ activation, and motor activation stages were performed before bypass, at 1 month, and 3 months after bypass. The result of the M-SPECT was expressed as negative or positive. Before bypass: In all 17 cases, SPECT studies of the affected side showed reduction of resting cerebral blood flow (CBF) and reduction of cerebrovascular reserve capacity (CVRC). Eight cases were positive in the M-SPECT study. One week after bypass: The resting CBF increased in seven cases. Four showed preoperative positive M-SPECT. Eight cases showed improvement of the CVRC. Twelve cases were positive in M-SPECT, and two were negative in the preoperative M-SPECT. Three months after bypass: Thirteen cases showed improvement in the resting CBF, and fourteen cases showed improvement of the CVRC. Fourteen cases were positive in the M-SPECT, and among these, 6 were negative in the preoperative M-SPECT. There was a discrepancy between the improvement in CVRC and M-SPECT. M-SPECT study can provide information about the degree of hemodynamic compromise and effect of bypass surgery. (author)

  8. Effect of bypass on the motor activation SPECT compared to the acetazolamide SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kawaguchi, Shoichiro; Iwahashi, Hideaki; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime [Nara Medical Univ., Kashihara (Japan)

    2002-03-01

    The authors evaluated and analyzed motor activation single photon emission computed tomography (M-SPECT) in ischemic cerebrovascular disease compared to resting and acetazolamide (ACZ) activated SPECT studies. Seventeen cases with STA-MCA bypass performed for ischemic cerebrovascular disease were examined. The SPECT studies consisting of resting, ACZ activation, and motor activation stages were performed before bypass, at 1 month, and 3 months after bypass. The result of the M-SPECT was expressed as negative or positive. Before bypass: In all 17 cases, SPECT studies of the affected side showed reduction of resting cerebral blood flow (CBF) and reduction of cerebrovascular reserve capacity (CVRC). Eight cases were positive in the M-SPECT study. One week after bypass: The resting CBF increased in seven cases. Four showed preoperative positive M-SPECT. Eight cases showed improvement of the CVRC. Twelve cases were positive in M-SPECT, and two were negative in the preoperative M-SPECT. Three months after bypass: Thirteen cases showed improvement in the resting CBF, and fourteen cases showed improvement of the CVRC. Fourteen cases were positive in the M-SPECT, and among these, 6 were negative in the preoperative M-SPECT. There was a discrepancy between the improvement in CVRC and M-SPECT. M-SPECT study can provide information about the degree of hemodynamic compromise and effect of bypass surgery. (author)

  9. Prospects for the application of GaN power devices in hybrid electric vehicle drive systems

    International Nuclear Information System (INIS)

    Su, Ming; Chen, Chingchi; Rajan, Siddharth

    2013-01-01

    GaN, a wide bandgap semiconductor successfully implemented in optical and high-speed electronic devices, has gained momentum in recent years for power electronics applications. Along with rapid progress in material and device processing technologies, high-voltage transistors over 600 V have been reported by a number of teams worldwide. These advances make GaN highly attractive for the growing market of electrified vehicles, which currently employ bipolar silicon devices in the 600–1200 V class for the traction inverter. However, to capture this billion-dollar power market, GaN has to compete with existing IGBT products and deliver higher performance at comparable or lower cost. This paper reviews key achievements made by the GaN semiconductor industry, requirements of the automotive electric drive system and remaining challenges for GaN power devices to fit in the inverter application of hybrid vehicles. (invited review)

  10. Color optimization of conjugated-polymer/InGaN hybrid white light emitting diodes by incomplete energy transfer

    International Nuclear Information System (INIS)

    Chang, Chi-Jung; Lai, Chun-Feng; Madhusudhana Reddy, P.; Chen, Yung-Lin; Chiou, Wei-Yung; Chang, Shinn-Jen

    2015-01-01

    By using the wavelength conversion method, white light emitting diodes (WLEDs) were produced by applying mixtures of polysiloxane and fluorescent polymers on InGaN based light emitting diodes. UV curable organic–inorganic hybrid materials with high refractive index (1.561), compromised optical, thermal and mechanical properties was used as encapsulants. Red light emitting fluorescent FABD polymer (with 9,9-dioctylfluorene (F), anthracene (A) and 2,1,3-benzothiadiazole (B), and 4,7-bis(2-thienyl)-2,1,3-benzothiadiazole (D) repeating units) and green light emitting fluorescent FAB polymer were used as wavelength converters. The encapsulant/fluorescent polymer mixture and InGaN produce the white light by incomplete energy transfer mechanism. WLEDs with high color rendering index (CRI, about 93), and tunable correlated color temperature (CCT) properties can be produced by controlling the composition and chemical structures of encapsulating polymer and fluorescent polymer in hybrid materials, offering cool-white and neutral-white LEDs. - Highlights: • Highly efficient white light-emitting diodes (WLEDs) were produced. • Conjugated-polymer/InGaN hybrid WLEDs by incomplete energy transfer mechanism. • WLEDs with high color-rendering index and tunable correlated color temperature. • Polysiloxane encapsulant with superior optical, mechanical and thermal properties

  11. Programmable electronics for low-cost small animal PET/SPECT imaging

    International Nuclear Information System (INIS)

    Guerra, Pedro; Rubio, Jose L.; Kontaxakis, Georgios; Ortuno, Juan E.; Ledesma, Maria J.; Santos, Andres

    2006-01-01

    This work describes and characterizes the detector module of a novel positron/single photon emission (PET/SPECT) scanner for small animals. This detector consists of a YAP/LSO phoswich, a photomultiplier and acquisition front-end, and will be used as building block of a low-cost hybrid tomograph. The front-end processes data sampled at a fixed frequency, where a state-of-the-art programmable device estimates scintillation pulse parameters by means of digital algorithms. Finally, the estimated properties of the proposed detector module are used to model a rotating four-head scanner. The performance of the proposed PET/SPECT scanner is estimated and first results are promising in both modalities, deserving further research and optimization

  12. Gallium-67 and subphrenic abscesses: is delayed scintigraphy necessary

    International Nuclear Information System (INIS)

    Hopkins, G.B.; Mende, C.W.

    1975-01-01

    Forty postoperative patients with clinical and roentgenographic findings suggestive of subphrenic abscess were evaluated by early and delayed 67 Ga scintigraphy. Early 67 Ga scintigraphs obtained 6 hr after injection correctly localized seven right and five left subphrenic abscesses. In no instance was an abscess present on delayed scintigraphs that was not evident on the 6-hr study. Two patients with left subphrenic abscess had false-negative results on both early and delayed scintigraphy. No false-positive studies were recorded. Early 67 Ga scintigraphy can be a valuable noninvasive adjunct in the diagnosis of subphrenic abscess. (U.S.)

  13. Unbiased Photocatalytic Hydrogen Generation from Pure Water on Stable Ir-treated In 0.33 Ga 0.67 N Nanorods

    KAUST Repository

    Ebaid, Mohamed; Priante, Davide; Liu, Guangyu; Zhao, Chao; Sharizal Alias, Mohd; Buttner, Ulrich; Khee Ng, Tien; Taylor Isimjan, Tayirjan; Idriss, Hicham; Ooi, Boon S.

    2017-01-01

    InGaN-based nanostructures have recently been recognized as promising materials for efficient solar hydrogen generation. This is due to their chemical stability, adjustable optoelectronic properties, suitable band edge alignment, and large surface-to-volume ratio. The inherent high density of surface trapping states and the lack of compatible conductive substrates, however, hindered their use as stable photo-catalysts. We have designed, synthesized and tested an efficient photocatalytic system using stable In0.33Ga0.67N-based nanorods (NRs) grown on an all-metal stack substrate (Ti-Mo) for a better electron transfer process. In addition, we have applied a bifunctional ultrathin thiol-based organic surface treatment using 1,2-ethanedithiol (EDT), in which sulfur atoms protected the surface from oxidation. This treatment has dual functions, it passivates the surface (by the removal of dangling bonds) and creates ligands for linking Ir-metal ions as oxygen evolution centers on top of the semiconductor. This treatment when applied to In0.33Ga0.67N NRs resulted in a photo-catalyst that achieved 3.5% solar-to-hydrogen (STH) efficiency, in pure water (pH~7, buffer solution) under simulated one-sun (AM1.5G) illumination and without electrical bias. Over the tested period, a steady increase of the gas evolution rate was observed from which a turnover frequency of 0.23s-1 was calculated. The novel growth of InGaN-based NRs on a metal as well as the versatile surface functionalization techniques (EDT-Ir) have a high potential for making stable photo-catalysts with adjustable band gaps and band edges to harvest sun light.

  14. Unbiased Photocatalytic Hydrogen Generation from Pure Water on Stable Ir-treated In 0.33 Ga 0.67 N Nanorods

    KAUST Repository

    Ebaid, Mohamed

    2017-05-11

    InGaN-based nanostructures have recently been recognized as promising materials for efficient solar hydrogen generation. This is due to their chemical stability, adjustable optoelectronic properties, suitable band edge alignment, and large surface-to-volume ratio. The inherent high density of surface trapping states and the lack of compatible conductive substrates, however, hindered their use as stable photo-catalysts. We have designed, synthesized and tested an efficient photocatalytic system using stable In0.33Ga0.67N-based nanorods (NRs) grown on an all-metal stack substrate (Ti-Mo) for a better electron transfer process. In addition, we have applied a bifunctional ultrathin thiol-based organic surface treatment using 1,2-ethanedithiol (EDT), in which sulfur atoms protected the surface from oxidation. This treatment has dual functions, it passivates the surface (by the removal of dangling bonds) and creates ligands for linking Ir-metal ions as oxygen evolution centers on top of the semiconductor. This treatment when applied to In0.33Ga0.67N NRs resulted in a photo-catalyst that achieved 3.5% solar-to-hydrogen (STH) efficiency, in pure water (pH~7, buffer solution) under simulated one-sun (AM1.5G) illumination and without electrical bias. Over the tested period, a steady increase of the gas evolution rate was observed from which a turnover frequency of 0.23s-1 was calculated. The novel growth of InGaN-based NRs on a metal as well as the versatile surface functionalization techniques (EDT-Ir) have a high potential for making stable photo-catalysts with adjustable band gaps and band edges to harvest sun light.

  15. Radiolabeled porphyrin versus gallium-67 citrate for the detection of human melanoma in athymic mice

    International Nuclear Information System (INIS)

    Maric, N.; Chan, S. Ming; Hoffer, P.B.; Duray, P.

    1987-01-01

    We performed the biodistribution and imaging studies of 111 In and 67 Ga labeled tetra(4-N-methylpyridyl) porphine, (T4NMPYP), and compared it to that of 67 Ga citrate in athymic mice bearing a human melanoma xenograft. The biodistribution results of both 111 In and 67 Ga labeled T4NMPYP (3, 6, 24, and 48 hours) were similar but differed from that of 67 Ga citrate (48 hours). The optimum tumor uptake of both radiolabeled porphyrins was at 6 hours postinjection and was lower than the tumor uptake of 67 Ga citrate at 48 hours postinjection. Kidney was the only organ showing higher uptake of radiolabeled porphyrin compared to that of 67 Ga citrate. The imaging studies performed with 111 In T4NMPYP and 67 Ga citrate correspond to the biodistribution results. Osteomyelitis present in one mouse showed good localization of 111 In T4NMPYP. 15 refs., 3 figs., 5 tabs

  16. Study of distribution of /sup 169/Yb, /sup 67/Ga and /sup 111/In in tumor tissue by macroautoradiography. Comparison between viable tumor tissue and necrotic tumor tissue

    Energy Technology Data Exchange (ETDEWEB)

    Ando, A; Sanada, S; Hiraki, T [Kanazawa Univ. (Japan). School of Paramedicine; Doishita, K; Ando, I

    1977-01-01

    The localization of /sup 169/Yb, /sup 67/Ga and /sup 111/In in tumor tissues was determined macroautoradiographically. /sup 169/Yb-citrate, /sup 67/Ga-citrate and /sup 111/In-citrate were injected intravenously into rats which had received subcutaneously transplantations of Yoshida sarcoma, and were injected intraperitoneally to the mice which had received subcutaneous transplantations of Ehrlich tumor. These animals were sacrificed 3, 24 and 48 hours after injection. The tumor tissues were frozen in n-hexane (-70/sup 0/C) cooled with dry ice-acetone. After this, the frozen tumor tissues were cut into thin serial sections (10 ..mu..m) in a cryostat (-20/sup 0/C). One of these sections was then placed on x-ray film, and this film was developed after exposure of several days. The next slice of each of these sections were stained using the hematoxylin and eosin. From the observations of these autoradiogram and H-E stained slice, the following results were obtained. Concentration of /sup 169/Yb, /sup 67/Ga and /sup 111/In was predominant in viable tumor tissue rather than in necrotic tumor tissue, regardless of time after administration. /sup 67/Ga and /sup 111/In were distributed uniformly in viable tumor tissue, but there was greater deposition of /sup 169/Yb in viable tumor tissue neighboring the necrotic tumor.

  17. Clinical value of SPECT/CT for evaluation of patients with painful knees after total knee arthroplasty- a new dimension of diagnostics?

    OpenAIRE

    Hirschmann, Michael T; Konala, Praveen; Iranpour, Farhad; Kerner, Anna; Rasch, Helmut; Friederich, Niklaus F

    2011-01-01

    Abstract Background The purpose of our study was to evaluate the clinical value of hybrid SPECT/CT for the assessment of patients with painful total knee arthroplasty (TKA). Methods Twenty-three painful knees in patients following primary TKA were assessed using Tc-99m-HDP-SPECT/CT. Rotational, sagittal and coronal position of the TKA was assessed on 3D-CT reconstructions. The level of the SPECT-tracer uptake (0-10) and its anatomical distribution was mapped using a validated localization sch...

  18. Gallium-67-labeled lactam bridge-cyclized alpha-MSH peptides with enhanced melanoma uptake and reduced renal uptake.

    Science.gov (United States)

    Guo, Haixun; Gallazzi, Fabio; Miao, Yubin

    2012-06-20

    The purpose of this study was to examine the melanoma targeting and pharmacokinetic properties of (67)Ga-DOTA-GGNle-CycMSHhex {(67)Ga-1,4,7,10-tetraazacyclononane-1,4,7,10-tetraacetic acid-Gly-Gly-Nle-c[Asp-His-DPhe-Arg-Trp-Lys]-CONH2} and (67)Ga-NOTA-GGNle-CycMSHhex {(67)Ga-1,4,7-triazacyclononane-1,4,7-triacetic acid-Gly-Gly-Nle-c[Asp-His-DPhe-Arg-Trp-Lys]-CONH2} and compare with (67)Ga-DOTA-GlyGlu-CycMSH {(67)Ga-DOTA-Gly-Glu-c[Lys-Nle-Glu-His-DPhe-Arg-Trp-Gly-Arg-Pro-Val-Asp]} we previously reported. DOTA-GGNle-CycMSHhex and NOTA-GGNle-CycMSHhex were synthesized using fluorenylmethyloxy carbonyl (Fmoc) chemistry. The melanocortin-1 (MC1) receptor binding affinity of NOTA-GGNle-CycMSHhex was determined in B16/F1 melanoma cells and compared with DOTA-GGNle-CycMSHhex. The melanoma targeting and pharmacokinetic properties of (67)Ga-NOTA-GGNle-CycMSHhex and (67)Ga-DOTA-GGNle-CycMSHhex were determined in B16/F1 melanoma-bearing C57 mice. NOTA-GGNle-CycMSHhex and DOTA-GGNle-CycMSHhex displayed comparable MC1 receptor binding affinities (1.6 vs 2.1 nM) in B16/F1 melanoma cells. Both (67)Ga-NOTA-GGNle-CycMSHhex and (67)Ga-DOTA-GGNle-CycMSHhex exhibited dramatically enhanced melanoma uptake and reduced renal uptake than (67)Ga-DOTA-GlyGlu-CycMSH in B16/F1 melanoma-bearing C57 mice. Furthermore, (67)Ga-NOTA-GGNle-CycMSHhex exhibited more favorable radiolabeling conditions (>85% radiolabeling yields started at 37 °C), as well as higher tumor/kidney uptake ratios than (67)Ga-DOTA-GGNle-CycMSHhex at 0.5, 2, and 24 h postinjection. High melanoma uptake coupled with low renal uptake highlighted the potential of (67)Ga-NOTA-GGNle-CycMSHhex for melanoma imaging and therapy.

  19. Reference Range of Functional Data of Gated Myocardial Perfusion SPECT by Quantitative Gated SPECT of Cedars-Sinai and 4D-MSPECT of Michigan University

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Do Young; Kim, Moo Hyun; Kim, Young Dae [College of Medicine, Univ. of Donga, Pusan (Korea, Republic of)

    2003-07-01

    Various programs have been developed for gating of myocardial perfusion SPECT. Among the those program, the most popular program is the Quantitative Gated SPECT (QGS)? developed by Cedars-Sinai hospital and most recently released program is 4D-MSPECT? developed by university of Michigan. It is important to know the reference range of the functional data of gated myocardial perfusion SPECT because it is necessary to determine abnormality of individual patient and echocardiographic data is different from those of gated SPECT. Tc-99m MIBI gated myocardial perfusion SPECT image was reconstructed by dual head gamma camera (Siemens, BCAM, esoft) as routine procedure and analyzed using QGS? and 4D-MSPECT? program. All patients (M: F=9: 18, Age 69{+-}9 yrs) showed normal myocardial perfusion. The patients with following characteristics were excluded: previous angina or MI history, ECG change with Q wave or ST-T change, diabetes melitius, hypercholesterolemia, typical chest pain, hypertension and cardiomyopathy. Pre-test likelihood of all patients was low. (1) In stress gated SPECT by QGS?, EDV was 73{+-}25 ml, ESV 25{+-}14 ml, EF 67{+-}11 % and area of first frame of gating 106.4{+-}21cm{sup 2}. In rest gated SPECT, EDV was 76{+-}26 ml, ESV 27{+-}15 ml, EF 66{+-}12 and area of first frame of gating 108{+-}20cm{sup 2}. (2) In stress gated SPECT by 4D-MSPECT?, EDV was 76{+-}28 ml, ESV 23{+-}16 ml, EF 72{+-}11 %, mass 115{+-}24 g and ungated volume 42{+-}15 ml. In rest gated SPECT, EDV was 75{+-}27 ml, ESV 23{+-}12 ml, EF 71{+-}9%, mass 113{+-}25g and ungate dvolume 42{+-}15 ml, (3) s-EDV, s-EF, r-ESV and r-EF were significantly different between QGS? and 4D-MSPECT? (each p=0.016, p<0.001. p=0.003 and p=0.001). We determined the normal reference range of functional parameters by QGS? and 4D-MSPECT? program to diagnose individually the abnormality of patients. And the reference ranges have to adopted to be patients by each specific gating program.

  20. Prevalence and significance of gallium-67 uptake in the heart after open-heart surgery

    International Nuclear Information System (INIS)

    Huikuri, H.V.; Ikaeheimo, M.J.A.; Airaksinen, J.; Linnaluoto, M.M.; Heikkilae, J.T.; Takkunen, J.T.

    1988-01-01

    Radioactive gallium-67 (Ga-67) has been shown to accumulate within areas of pericardial inflammation. The present study estimated prospectively the prevalence and clinical significance of Ga-67 uptake in the heart in 62 patients 10 to 16 days after open-heart surgery. Of 62 patients studied, markedly diffuse Ga-67 uptake was detected in 21 (34%) and focal or mild diffuse uptake in 23 (37%). Results were negative in 18 (29%). Nine patients with a negative scan result (50%) had received corticosteroid therapy before imaging, whereas only 2 patients with a positive scan result (5%) were receiving steroids. The erythrocyte sedimentation rate and C-reactive protein level were both higher in patients with Ga-67 uptake compared with those with a negative scan result (p less than 0.01 in both). No other clinical, echocardiographic or electrocardiographic indicators of postpericardiotomy syndrome were related to Ga-67 uptake. No patient developed cardiac tamponade or constrictive pericarditis during the 12-week follow-up and the Ga-67 scan results did not predict the occlusion of coronary artery bypass grafts. Thus, pericardial inflammation manifested as Ga-67 uptake is a common finding after open-heart surgery and appears to be a benign condition

  1. Clinical significance of gallium-67 scintigraphy in assessing pulmonary lesions of sarcoidosis and idiopathic pulmonary fibrosis

    International Nuclear Information System (INIS)

    Fujishima, Seitaro; Kanazawa, Minoru; Yamasawa, Fumihiro; Kubo, Atsushi; Hashimoto, Shozo; Yokoyama, Tetsuro

    1992-01-01

    To evaluate whether one can predict the course and prognosis of interstitial lung diseases from lung gallium-67 ( 67 Ga) uptake, we studied 31 subjects with sarcoidosis and 28 with idiopathic pulmonary fibrosis (IPF) retrospectively. We quantified the lung 67 Ga uptake using posterior scans by Line's method, and calculated a visual index (VI). The normal range of 67 Ga uptake was defined as less than 65 VI values, obtained from the 95 percent confidence interval of the control subjects. All subjects with stage I sarcoidosis, having only bilateral hilar lymphadenopathy (BHL) on chest X-ray, revealed normal lung 67 Ga uptake. Fifty percent of patients with stage II sarcoidosis, with both BHL and pulmonary involvement on chest X-ray, showed increased lung 67 Ga uptake. The patients with increased lung 67 Ga uptake showed decreased percent vital capacity and increased alveolar-arterial oxygen tension difference, but none of them showed clinical deterioration during the follow-up period of more than 6 months. Fifty-four percent of subjects with IPF sowed increased lung 67 Ga uptake. But there was no difference between the subgroups with normal and increased lung 67 Ga uptake with respect to the severity of dyspnea, percent vital capacity, arterial oxygen tension, or alveolar-arterial oxygen tension difference. There was also no difference between the two subgroups of IPF in the cumulative percent survival after either the onset of symptoms or the 67 Ga scintigram. We conclude that lung 67 Ga uptake was not able to predict the clinical course or the prognosis of patients with sarcoidosis and IPF. (author)

  2. Hybridization between Cottus gobio and Cottus poecilopus in the Odra River drainage basin (Czech Republic)

    Czech Academy of Sciences Publication Activity Database

    Marešová, Eva; Lusková, Věra; Lojkásek, B.

    2012-01-01

    Roč. 67, č. 4 (2012), s. 788-795 ISSN 0006-3088 R&D Projects: GA MŽP(CZ) SPII2D1/9/07 Institutional support: RVO:68081766 Keywords : bullheads * hybrid zones * microsatellites * S7 nuclear gene Subject RIV: EG - Zoology Impact factor: 0.506, year: 2012

  3. Dephasing of LO-phonon-plasmon hybrid modes in n-type GaAs

    Science.gov (United States)

    Vallée, F.; Ganikhanov, F.; Bogani, F.

    1997-11-01

    The relaxation dynamics of coherent phononlike LO-phonon-plasmon hybrid modes is investigated in n-doped GaAs using an infrared time-resolved coherent anti-Stokes Raman scattering technique. Measurements performed for different crystal temperatures in the range 10-300 K as a function of the electron density injected by doping show a large reduction of the hybrid mode dephasing time compared to the bare LO-phonon one for densities larger than 1016 cm-3. The results are interpreted in terms of coherent decay of the LO-phonon-plasmon mixed mode in the weak-coupling regime and yield information on the plasmon and electron relaxation. The estimated average electron momentum relaxation times are smaller than those deduced from Hall mobility measurements, as expected from our theoretical model.

  4. Comparison of Ga-68 DOTA-TATE and Ga-68 DOTA-LAN PET/CT imaging in the same patient group with neuroendocrine tumours: preliminary results.

    Science.gov (United States)

    Demirci, Emre; Ocak, Meltem; Kabasakal, Levent; Araman, Ahmet; Ozsoy, Yildiz; Kanmaz, Bedii

    2013-08-01

    Recent studies have suggested that PET imaging with Ga-68-labelled DOTA-somatostatin analogues such as octreotide and octreotate is useful in diagnosing neuroendocrine tumours (NETs) and has superior value over both computed tomography and planar and SPECT somatostatin receptor scintigraphy. The aim of the present study was to evaluate the role of Ga-68 DOTA-lanreotide (Ga-68-DOTA-LAN) in patients with somatostatin receptor (sst)-expressing tumours and to compare the results of Ga-68 DOTA-D-Phe1-Tyr3-octreotate (Ga-68-DOTA-TATE) in the same patient population. Twelve patients with NETs who were referred to our department for somatostatin receptor scintigraphy were included in the study. There were four patients with well-differentiated neuroendocrine tumour (WDNET) grade 1, two patients with WDNET grade 2, and three patients with poorly differentiated neuroendocrine carcinoma (PDNEC) grade 3. There was also one patient with medullary thyroid cancer, one patient with meningioma and one patient with MEN-1. All patients underwent two consecutive PET imaging studies with Ga-68-DOTA-TATE and Ga-68 DOTA-LAN. All images were evaluated visually, and maximum standardized uptake value was calculated for quantitative evaluation. On visual examination of maximum intensity projection images, GA-68 DOTA-LAN was seen to have high background activity and high bone marrow uptake. Both tracers defined 67 lesions. Ga-68 DOTA-TATE images revealed 63 (94%) clearly defined lesions, missing four lesions. In contrast, Ga-68 DOTA-LAN images defined only 23 (44%) lesions, missing 44 (56%) lesions. Thirty-two bone lesions were detected on Ga-68-DOTA-TATE images. Among them, only 11 (34%) were positive on Ga-68 DOTA-LAN images, whereas 21 (66%) were negative. When we evaluated liver, mediastinum and gastrointestinal tract lesions, Ga-68 DOTA-LAN was seen to be positive for 12 (34%) lesions and negative for 23 (66%) lesions. Although the results are preliminary, the image quality obtained by

  5. Hybrid cardiac imaging: SPECT/CT and PET/CT. A joint position statement by the European Association of Nuclear Medicine (EANM), the European Society of Cardiac Radiology (ESCR) and the European Council of Nuclear Cardiology (ECNC)

    DEFF Research Database (Denmark)

    Flotats, Albert; Gutberlet, Matthias; Knuuti, Juhani

    2011-01-01

    . The European Association of Nuclear Medicine (EANM), the European Society of Cardiac Radiology (ESCR) and the European Council of Nuclear Cardiology (ECNC) in this paper want to present a position statement of the institutions on the current roles of SPECT/CT and PET/CT hybrid cardiac imaging in patients...

  6. Substernal thyroid carcinoma detected by 67Ga scan in a patient with normal 131I scan

    International Nuclear Information System (INIS)

    Kim, e.E.; Maruyama, Y.; Deland, F.H.

    1978-01-01

    A patient with a superior mediastinal mass on an admission chest radiograph was initially evaluated by an 131 I thyroid scan which failed to demonstrate a substernal thyroid. However, the tomographic 67 Ga scan clearly showed an abnormal uptake in the area corresponding to the mass lesion on radiographic examination. Subsequent resection and biopsy of the substernal mass revealed a poorly differentiated follicular carcinoma with foci of anaplastic carcinoma. The differential diagnosis of the anterior mediastinal mass and the usefullness of the tomographic gallium scan are briefly discussed

  7. Clinical Utility of SPECT/CT Imaging Post-Radioiodine Therapy: Does It Enhance Patient Management in Thyroid Cancer?

    Science.gov (United States)

    Hassan, Fahim U; Mohan, Hosahalli K

    2015-12-01

    The aim of this study was to evaluate post-therapy iodine-131 single-photon emission computed tomography/computed tomography ((131)I-SPECT/CT) imaging in comparison to conventional planar (131)I whole-body imaging, and to assess its clinical impact on the management of patients. We retrospectively reviewed planar (131)I whole-body and (131)I-SPECT/CT imaging findings in 67 patients who underwent (131)I therapy for thyroid cancer. Two nuclear medicine physicians reviewed the scans independently. The foci of increased tracer uptake were identified in the neck, thorax and elsewhere. Within the neck, the foci of (131)I-increased uptake were graded qualitatively as probable or definite uptake in thyroid remnants and probable or definite uptake in the lymph nodes. Serum thyroglobulin level, histopathology and other imaging findings served as the reference standard. Of the 67 patients, 57 (85%) had radioiodine avid disease and 10 (15%) demonstrated non-radioiodine avid disease. Overall, post-therapy (131)I-SPECT/CT downstaged lymph node staging in 10 patients and upstaged it in 4 patients. This translated into a change of management for 9/57 (16%) patients with radioiodine avid disease. A change of management was observed in 5/10 patients with non-radioiodine avid disease confirmed in the post-(131)I-SPECT/CT study. Additionally, clinically significant findings such as incidental lung cancer, symptomatic pleural effusion and consolidation were also diagnosed in both groups of patients. In patients with thyroid cancer, (131)I-SPECT/CT is a valuable addition to standard post-therapy planar imaging. SPECT/CT also improved diagnostic confidence and provided crucial clinical information leading to change of management for a significant number of these patients.

  8. Development of method to chemical separation of gallium-67 by thermal diffusion technique

    International Nuclear Information System (INIS)

    Martins, Patricia de Andrade

    2012-01-01

    Radioisotopes of gallium have been studied and evaluated for medical applications since 1949. Over the past 50 years 67 Ga has been widely used in the diagnosis of various diseases, including acute and chronic inflammatory lesions, bacterial or sterile and several types of tumors. In Brazil 30% of clinics that provide services for Nuclear Medicine use 67 Ga citrate and the demand for 67 G a at IPEN-CNEN/SP is 37 GBq (1 Ci)/week. The 67 Ga presents physical half-life of 3.26 days (78 hours) and decays 100% by electron capture to stable 67 Zn. Its decay includes the emission of γ rays with energies of 93.3 keV (37%), 184.6 keV (20.4%), 300.2 keV (16.6%) and 888 keV (26%). In the past 67 Ga was produced by the reaction 68 Zn (p, 2n) 67 Ga at IPEN-CNEN/SP. After irradiation, the target was dissolved in concentrated HCl and the solution percolated through a cationic resin DOWEX 50W-X8, 200-400 mesh, conditioned with 10 mol L -1 HCl. Zinc, nickel and copper were eluted in 10 mol L -1 HCl and 67 Ga 3.5 mol L -1 HCl. The final product was obtained as 67 Ga citrate. This work presents a new, fast, direct and efficient method for the chemical separation of 67 G a by thermal diffusion (heating of the target) combined with concentrated acetic acid extraction. Purification was performed by ion exchange chromatography. Natural zinc electrodeposition was performed on nickel/copper plates as substrate and the zinc deposits were adherent to the substrate, slightly shiny and uniform. The targets were irradiated with 26 MeV protons and integrated current of 10 μA.h. After irradiation, the targets were heated at 300 deg C for 2 hours and placed in contact with concentrated acetic acid for 1 hour. The average yield of extraction of 67 Ga was (72 ± 10)%. This solution was evaporated and the residue was taken up in 0.5 mol L -1 NH 4 OH. The 67 G a was purified on cationic resin Dowex 50WX8 in NH 4 OH medium. The 67 Ga recovery was (98 ± 2)%. This solution was evaporated and taken up

  9. SPECT in psychiatry. SPECT in der Psychiatrie

    Energy Technology Data Exchange (ETDEWEB)

    Barocka, A. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany)); Feistel, H. (Nuklearmedizinische Klinik, Erlangen (Germany)); Ebert, D. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany)); Lungershausen, E. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany))

    1993-08-13

    This review presents Single Photon Emission Computed Tomography (SPECT) as a powerful tool for clinical use and research in psychiatry. Its focus is on regional cerebral blood flow, measured with technetium labelled HMPAO. In addition, first results with brain receptor imaging, concerning dopamin-D[sub 2] and benzodiazepine receptors, are covered. Due to major improvements in image quality, and impressive number of results has been accumulated in the past three years. The authors caution against using SPECT results as markers for disease entities. A finding like 'hypofrontality' is considered typical of a variety of mental disorders. Clearly both, more experience with SPECT and contributions from psychopathology, are needed. (orig.)

  10. Clinical significance of gallium-67 scintigraphy in assessing pulmonary lesions of sarcoidosis and idiopathic pulmonary fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Fujishima, Seitaro; Kanazawa, Minoru; Yamasawa, Fumihiro; Kubo, Atsushi; Hashimoto, Shozo; Yokoyama, Tetsuro (Keio Univ., Tokyo (Japan). School of Medicine)

    1992-03-01

    To evaluate whether one can predict the course and prognosis of interstitial lung diseases from lung gallium-67 ({sup 67}Ga) uptake, we studied 31 subjects with sarcoidosis and 28 with idiopathic pulmonary fibrosis (IPF) retrospectively. We quantified the lung {sup 67}Ga uptake using posterior scans by Line's method, and calculated a visual index (VI). The normal range of {sup 67}Ga uptake was defined as less than 65 VI values, obtained from the 95 percent confidence interval of the control subjects. All subjects with stage I sarcoidosis, having only bilateral hilar lymphadenopathy (BHL) on chest X-ray, revealed normal lung {sup 67}Ga uptake. Fifty percent of patients with stage II sarcoidosis, with both BHL and pulmonary involvement on chest X-ray, showed increased lung {sup 67}Ga uptake. The patients with increased lung {sup 67}Ga uptake showed decreased percent vital capacity and increased alveolar-arterial oxygen tension difference, but none of them showed clinical deterioration during the follow-up period of more than 6 months. Fifty-four percent of subjects with IPF sowed increased lung {sup 67}Ga uptake. But there was no difference between the subgroups with normal and increased lung {sup 67}Ga uptake with respect to the severity of dyspnea, percent vital capacity, arterial oxygen tension, or alveolar-arterial oxygen tension difference. There was also no difference between the two subgroups of IPF in the cumulative percent survival after either the onset of symptoms or the {sup 67}Ga scintigram. We conclude that lung {sup 67}Ga uptake was not able to predict the clinical course or the prognosis of patients with sarcoidosis and IPF. (author).

  11. Loss of circulating 67Ga-transferrin due to its accumulation in malignant tumors of the rat and its relation to the synthesis of hemoglobin

    International Nuclear Information System (INIS)

    Kratzer, J.

    1981-01-01

    Taking into account earlier findings of other study groups, the author draws the following conclusions: 1. The elimination of 67 Ga-labelled transferrin from the blood of tumor carrier rats is accelerated as compared to normal. The acceleration is the more marked the greater the tumor mass and the higher its proliferation speed are. 2. The eliminated 67 Ga transferrin is detectable in the tumor by scintiscanning, and its retention increases concurrently with the tumor proliferation rate. 3. These tumor-dependent losses of transferrin entail a perturbation of reticulocytal Fe utilization and cause anemia, which is again aggravated as the tumor mass and its malignant nature increase. 4. If the tumor can be eliminated by therapy, the anemia disappears completely. (orig./MG) [de

  12. Diffuse abdominal gallium-67 citrate uptake in salmonella infections

    International Nuclear Information System (INIS)

    Garty, I.; Koren, A.

    1987-01-01

    Two pediatric patients with salmonella infections (one with typhoid fever and the second with salmonella C2 gastroenteritis), had a diffuse abdominal uptake of Ga-67 citrate. The possible explanation for this finding is discussed. Salmonella infection should be included as a cause in the differential diagnosis of diffuse accumulation of Ga-67 citrate

  13. Experimental MRI-SPECT insert system with Hybrid Semiconductor detectors Timepix for MR animal scanner Bruker 47/20

    Science.gov (United States)

    Zajicek, J.; Burian, M.; Soukup, P.; Novak, V.; Macko, M.; Jakubek, J.

    2017-01-01

    Multimodal medical imaging based on Magnetic Resonance is mainly combinated with one of the scintigraphic method like PET or SPECT. These methods provide functional information whereas magnetic resonance imaging provides high spatial resolution of anatomical information or complementary functional information. Fusion of imaging modalities allows researchers to obtain complimentary information in a single measurement. The combination of MRI with SPECT is still relatively new and challenging in many ways. The main complication of using SPECT in MRI systems is the presence of a high magnetic field therefore (ferro)magnetic materials have to be eliminated. Furthermore the application of radiofrequency fields within the MR gantry does not allow for the use of conductive structures such as the common heavy metal collimators. This work presents design and construction of an experimental MRI-SPECT insert system and its initial tests. This unique insert system consists of an MR-compatible SPECT setup with CdTe pixelated sensors Timepix tungsten collimators and a radiofrequency coil. Measurements were performed on a gelatine and tissue phantom with an embedded radioisotopic source (57Co 122 keV γ ray) inside the RF coil by the Bruker BioSpec 47/20 (4.7 T) MR animal scanner. The project was performed in the framework of the Medipix Collaboration.

  14. [Purification of 67Cu]. Progress report

    International Nuclear Information System (INIS)

    DeNardo, S.J.

    1994-01-01

    This report documents progress made in several areas of research and describes results which have not yet been published. These areas include: Purification of 67 Cu; Macrocyclic chelates for targeted therapy; Studies of biologic activation associated with molecular receptor increase and tumor response in ChL6/L6 protocol patients; Lym-1 single chain genetically engineered molecules; Analysis of molecular genetic coded messages to enhance tumor response; Human dosimetry and therapeutic human use radiopharmaceuticals; studies in phantoms; Quantitative SPECT; Preclinical studies; and Clinical studies

  15. Gadopentate interference in gallium-67 tumour imaging: fact or fiction?

    International Nuclear Information System (INIS)

    Baker, R.J.

    1998-01-01

    Full text: Gallium-67-citrate is the most widely used tumour imaging radiopharmaceutical. It is known that the metal ions Sc(III), Au(III), FE(III) and inactive Ga(III), as well as chemotherapy, interfere leading to poor quality scans, characterised by pronounced bone uptake and loss of tumour avidity. In 1990, Hattner and White reported a scan of this nature following administration of the paramagnetic contrast agent gadolinium-DTPA (Gadopentate). Suggestions to account for these changes included in vivo dissociation or the presence of free DTPA in the formulation. Since the use of MRI is increasing dramatically, this potential interference is a vital issue for nuclear medicine. To investigate this phenomenon, gadolinium-DTPA solutions were prepared containing Gd and DTPA in the molar ratios 0.9:1, 1.0:1 and 1.1:1. Their effect on 67 Ga biodistribution at 24 h was investigated using mature female Balb/c mice after i.v. 67 Ga-citrate, injected 4 h after i.v. GD-DTPA. The model was verified by identical studies using inactive GA(III) and FE(III) at 0. 1 mmol/kg. The effects of GD(III) and DTPA ligand at this dose were also determined . Following administration of GD-DTPA up to 0.5 mmol/kg, no significant changes in 67 Ga biodistribution were observed. Minor changes occurred after 0. 1 mmol/kg Gd(III), notably increased renal (49%) and splenic (92%) uptake. With free DTPA, slightly higher blood (33%) and bone (22%) levels were found, but other tissues were not affected. These differences are unable to account for the marked scan changes reported above. However, inactive GA(III) and FE(III) caused a reduction of 67 Ga in all tissues except bone. It is concluded that GD-DTPA or its constituents do not significantly alter the biodistribution of 67 Ga-citrate in mice. The reported scan changes may be the result of extensive chemotherapy

  16. {sup 111}In-DOTA-dPhe{sup 1}-Tyr{sup 3}-octreotide, {sup 111}In-DOTA-lanreotide and {sup 67}Ga citrate scintigraphy for visualisation of extranodal marginal zone B-cell lymphoma of the MALT type: a comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Li, Shuren; Kurtaran, Amir; Li, Mei; Traub-Weidinger, Tatjana; Kienast, Oskar [Department of Nuclear Medicine, University of Vienna, Waehringer Guertel 18-20, 1090, Vienna (Austria); Schima, Wolfgang [Department of Nuclear Medicine, University of Vienna, Waehringer Guertel 18-20, 1090, Vienna (Austria); Department of Radiodiagnostics, University of Vienna (Austria); Angelberger, Peter [Research Center Seibersdorf (Austria); Virgolini, Irene [Institute for Nuclear Medicine, Vienna Hospital Lainz (Austria); Ludwig-Boltzman Institute for Nuclear Medicine, Vienna (Austria); Raderer, Markus [Department of Internal Medicine I, Division of Oncology, University of Vienna (Austria); Dudczak, Robert [Department of Nuclear Medicine, University of Vienna, Waehringer Guertel 18-20, 1090, Vienna (Austria)

    2003-08-01

    Somatostatin receptor (SSTR) scintigraphy and gallium-67 citrate ({sup 67}Ga) scintigraphy have been used for visualisation of Hodgkin's lymphoma and non-Hodgkin's lymphoma. However, experience with B-cell lymphoma of the mucosa-associated lymphoid tissue (MALT) type is very limited. The aim of this study was to prospectively compare the {sup 67}Ga scintigraphy results with those obtained by {sup 111}In-DOTA-dPhe{sup 1}-Tyr{sup 3}-octreotide ({sup 111}In-DOTA-TOCT) and {sup 111}In-DOTA-lanreotide ({sup 111}In-DOTA-LAN) scintigraphy in patients with proven MALT-type lymphoma. Comparative scintigraphic examinations using {sup 67}Ga, {sup 111}In-DOTA-TOCT and {sup 111}In-DOTA-LAN were performed in 18 patients (11 female and 7 male, median age 64{+-}15 years) with histologically verified MALT-type lymphomas of various origin. Planar and single-photon emission tomography imaging acquisitions were performed after injection of a mean dose of 185{+-}26 MBq {sup 67}Ga and 165{+-}20 MBq {sup 111}In-DOTA-TOCT or {sup 111}In-DOTA-LAN. All scintigraphic results were correlated with other conventional examinations including gastroscopy, colonoscopy, endosonoscopy, ophthalmologic investigation, CT of the thorax and abdomen and bone marrow biopsy. This comparative study showed that {sup 67}Ga scintigraphy found abnormalities in 10 of 16 patients (63%) and detected 18 of 31 clinically involved sites (58%), but was false positive in three patients. {sup 111}In-DOTA-TOCT found abnormalities in 9 of 15 patients (60%) and detected 15 of 27 clinical lesions (56%); it was false positive in two patients. {sup 111}In-DOTA-LAN scintigraphy showed abnormalities in 7 of 11 patients (64%) and found 12 of 22 clinical lesions (55%). False-positive {sup 111}In-DOTA-LAN scan results were found in two patients. For supra-diaphragmatic lesions, {sup 67}Ga scintigraphy detected 12 of 16 sites (75%). {sup 111}In-DOTA-TOCT scintigraphy revealed 7 of 15 lesions (47%). {sup 111}In

  17. Effect of food intake on the tissue distribution of gallium-67: concise communication

    International Nuclear Information System (INIS)

    Hayes, R.L.; Szymendera, J.J.; Byrd, B.L.

    1979-01-01

    Fasting affects the body retention and tissue distribution of Ga-67 in experimental animals. In Ga-67 experiments, therefore, a difference in food intake between treated and control animals might result in confusing side effects. We have observed this in irradiation studies. It is suggested that a fasting regimen should be imposed in any Ga-67 animal study where an alteration in food intake might be experienced in the treated group

  18. What significance can be attributed to high bone uptake of 67GA citrate in patients with HIV infection?

    International Nuclear Information System (INIS)

    Sabbatini, S.; Bini, A.; Turba, E.

    1989-01-01

    The authors observed high uptake of 67 Ga citrate in the spine and in some cases also in the ribs in 15 patients with HIV infection. 12 were also carriers of opportunistic infections, 14 had anaemia with reduced Hb synthesis. 9 were undergoing treatment with antifolic drugs or AZT. The high bone uptake of the radio-indicator was related to the presence of opportunistic infections, the eventual treatment with myelotoxic drugs and the reduction of Hb values. (orig.) [de

  19. The Performance of Ictal Brain SPECT Localizing for Epileptogenic Zone in Neocortical Epilepsy

    International Nuclear Information System (INIS)

    Kim, Eun Sik; Lee, Dong Soo; Hyun, In Young; Chung, June Key; Lee, Myung Chul; Koh, Chang Soon; Lee, Sang Kun; Chang, Kee Hyun

    1995-01-01

    The epileptogenic zones should be localized precisely before surgical resection of these zones in intractable epilepsy. The localization is more difficult in patients with neocortical epilepsy than in patients with temporal lobe epilepsy. This study aimed at evaluation of the usefulness of ictal brain perfusion SPECT for the localization of epileptogenic zones in neocortical epilepsy. We compared the performance of ictal SPECT with MRI referring to ictal scalp electroencephalography (sEEG). Ictal 99m Tc-HMPAO SPECT were done in twenty-one patients. Ictal EEG were also obtained during video monitoring. MRI were reviewed. According to the ictal sEEG and semiology, 8 patients were frontal lobe epilepsy, 7 patients were lateral temporal lobe epilepsy, 2 patients were parietal lobe epilepsy, and 4 patients were occipital lobe epilepsy. Ictal SPECT showed hyperperfusion in 14 patients(67%) in the zones which were suspected to be epileptogenic according to ictal EEG and semiology. MRI found morphologic abnormalities in 9 patients(43%). Among the 12 patients, in whom no epileptogenic zones were revealed by MR1, ictal SPECT found zones of hyperperfusion concordant with ictal sEEG in 9 patients(75%). However, no zones of hyperperfusion were found in 4 among 9 patients who were found to have cerebromalacia, abnormal calcification and migration anomaly in MRI. We thought that ictal SPECT was useful for localization of epileptogenic zones in neocortical epilepsy and especially in patients with negative findings in MRI.

  20. Spect-CT and PET: CT in the management of differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Khan, Shoukat H.

    2007-01-01

    Full text: With the advancement and evolution in medical technology notably imaging there has been a sea change in the overall management strategy of most of the cancers of human body. The present day functional, imaging with PET and MRI enables us to pick up a tumour at its cellular stage. Molecular imaging and nanotechnology have further added to this expanding armamentarium of cancer imaging and treatment. Thyroid cancer is one such cancer where the cutting edge biotechnology has dramatically changed the management profile of a disease. Thyroid cancer can safely be classified as one of the cancers which if optimally managed is curable. Hybrid and fusion imaging like SPECT-CT and PET-CT with their superior sensitivity and specificity have greatly improved the accuracy of disease detection and reduced drastically the false positive disease sites. Disease not detected by conventional planar imaging can now be detected and also anatomically localized using hybrid imaging modalities of SPECT-CT and PET-CT. An accurate detection and precise localization improves image interpretation and a treatment optimization in the curable cancer of thyroid

  1. Structural, electronic, and optical properties of GaInO{sub 3}: A hybrid density functional study

    Energy Technology Data Exchange (ETDEWEB)

    Wang, V., E-mail: wangvei@icloud.com; Ma, D.-M.; Liu, R.-J.; Yang, C.-M. [Department of Applied Physics, Xi' an University of Technology, Xi' an 710054 (China); Xiao, W. [State Key Lab of Nonferrous Metals and Processes, General Research Institute for Nonferrous Metals, Beijing 100088 (China)

    2014-01-28

    The structural, electronic, and optical properties of GaInO{sub 3} have been studied by first-principles calculations based on Heyd-Scuseria-Ernzerhof hybrid functional theory. The optical properties, including the optical reflectivity, refractive index, extinction coefficient, absorption coefficient, and electron energy loss are discussed for radiation up to 60 eV together with the calculated electronic structure. Our results predicted that GaInO{sub 3} displays good transparency over the whole vision region, which is in good agreement with the experimental data available in the literature.

  2. Study on localization diagnosis with SPECT rCBF image in childhood epilepsy: in comparison with EEG and MRI findings

    International Nuclear Information System (INIS)

    Wu Meiqian; Tang Jihong; Wu Jinchang; Shi Yizhen

    1999-01-01

    Objective: To evaluate the diagnostic value of SPECT rCBF imaging in localization of childhood epileptic foci. Methods: rCBF imaging was performed in 74 epileptic patients not in seizure and 10 epileptic patients right in seizure. EEG was performed in 84, MRI in 67 of the subjects mentioned above. All the results of three modalities were compared with each other. Results: The highest positive rate (82.14%) was found in SPECT rCBF imaging, the positive rate in EEG or MRI was 71.43 or 47.76%. The epileptic foci localized by EEG (60 abnormalities) and by MRI (32 abnormalities) were 70.59% or 58.82% in concordance with those by SPECT, respectively. Conclusions: SPECT rCBF imaging is a sensitive and effective method for epileptic foci localization. It may have some advantages over EEG and MRI in detecting and localizing epileptic foci. However, abnormal SPECT areas may cover some abnormalities which do not belong to epileptic category. A combination of these three methods (SPECT, EEG and MRI) will improve the positive rate and accuracy for localizing

  3. Measurements of 67Ga production cross section induced by protons on natZn in the low energy range from 1.678 to 2.444 MeV

    Science.gov (United States)

    Wachter, J. A.; Miranda, P. A.; Morales, J. R.; Cancino, S. A.; Correa, R.

    2015-02-01

    The experimental production cross section for the reaction natZn(p,x)67Ga has been measured in the energy range from 1.678 to 2.444 MeV. The methodology used in this work is based on characteristic X-ray emitted after irradiation by the daughter nuclei that decays by electron capture (EC) and the use of a complementary PIXE experiment. By doing so, expressions needed to determine cross section values are simplified since experimental factors such as geometric setup and an detector efficiency are avoided. 67Ga is a radionuclide particularly suited for this method since it decays by electron capture in 100% and the subsequent characteristic X-ray emission is easily detected. Natural zinc targets were fabricated by PVD technique and afterwards their thicknesses were determined by Rutherford Backscattering Spectrometry. Cross sections measurements were carried out by using the Van de Graaff accelerator located at Faculty of Sciences, University of Chile. It was found that our data for the natZn(p,x)67Ga reaction are, in general, in good agreement when compared to existing experimental data and to those calculated ALICE/ASH nuclear code. On the other hand, values predicted by Talys-1.6 are showing systematically lower magnitudes than our measured data.

  4. Comparative evaluation of renal transplant rejection with radioiodinated fibrinogen, /sup 99m/Tc--sulfur colloid, and 67Ga-citrate

    International Nuclear Information System (INIS)

    George, E.A.; Codd, J.E.; Newton, W.T.; Haibach, H.; Donati, R.M.

    1976-01-01

    The diagnostic accuracy, ease, and technical feasibility of imaging with 131 I- or 125 I-fibrinogen, 99 /sup m/Tc-sulfur colloid, and 67 Ga-citrate in renal transplant rejection are compared. Radiofibrinogen data resulted from literature review, radio-colloid data from 125 studies in 52 transplant patients, and gallium citrate data from 24 examinations in seven renal transplant patients performed simultaneously with the radiocolloid studies. Specificity of graft labeling during rejection appears to be similar with radiofibrinogen, 99 /sup m/Tc-sulfur colloid, and 67 Ga-citrate. For routine clinical use 99 /sup m/Tc-sulfur colloid surpasses radiofibrinogen and radiogallium because of its better imaging qualities with a permissible radiation dose, leading to better separation of positive and negative results. The 99 /sup m/Tc-sulfur colloid accumulates in areas of intravascular fibrin thrombosis in acute and chronic rejecting renal transplants. Hence, the mechanisms for accumulation of 99 /sup m/Tc-sulfur colloid and labeled fibrinogen in rejecting transplants would seem to be similar. Such physiologic properties as rapid blood clearance and such physical properties as short physical half-life combine to produce reliable graft visualization with adequate definition, thus favoring 99 /sup m/Tc-sulfur colloid as the single agent of choice for clinical evaluation of renal transplant rejection at this time

  5. NP-59 SPECT/CT Imaging in Stage 1 Hypertensive and Atypical Primary Aldosteronism: A 5-Year Retrospective Analysis of Clinicolaboratory and Imaging Features

    Directory of Open Access Journals (Sweden)

    Yi-Chun Chen

    2013-01-01

    Full Text Available Objective. We retrospectively analyzed all primary aldosteronism (PA patients undergoing NP-59 SPECT/CT imaging with regard to their clinicolaboratory and imaging features, investigation, and outcomes. Material and Methods. 11 PA patients who presented to our hospital for NP-59 SPECT/CT imaging between April 2007 and March 2012 and managed here were analyzed. Results. Among 11 PA patients, eight (73% had stage 1 hypertension, three (27% stage 2 hypertension, four (36% normal plasma aldosterone concentration, nine (82% nonsuppressed plasma renin activity (PRA, six (55% normal aldosterone-renin-ratio (ARR, eight (73% serum potassium ≧3 mEq/L, seven (64% subclinical presentation, seven (64% negative confirmatory testing, and four (36% inconclusive results on CT scan and seven (64% on planar NP-59 scan. All 11 (100% patients had positive results on NP-59 SPECT/CT scan. Two (18% met typical triad and nine (82% atypical triad. Among nine atypical PA patients, three (33% had clinical presentation, six (67% subclinical presentation, six (67% negative confirmatory testing, and four (44% inconclusive results on CT scan and six (67% on planar NP-59 scan. All patients had improved outcomes. Significant differences between typical and atypical PA existed in PRA and ARR. Conclusions. NP-59 SPECT/CT may provide diagnostic potential in stage 1 hypertensive and atypical PA.

  6. Abnormal 67Ga uptake in a fibrosarcoma of the pericardium with malignant transformation

    International Nuclear Information System (INIS)

    Hayashida, Kohei; Nishimura, Tsunehiko; Kumita, Shin-ichirou; Uehara, Toshiisa; Imakita, Masami

    1990-01-01

    A 31-year-old woman presented with general malaise, back pain, and edema of the lower extremities. A chest X-ray film showed an enlarged cardiac shadow and clear lung fields. A pericardial lesion with decreased activity on blood pool imaging and increased uptake on gallium citrate Ga67 imaging displaced the heart upwards and to the left. The pericardial mass showed an inhomogeneous signal intensity on MRI and was large enough to obstruct the venous return by compressing the heart. At operation, the mass was found to originate from the pericardium and was histologically identified as a malignant fibrosarcoma. Twelve years before, the patient had undergone an operation for the removal of a pericardial tumor which was histologically identified as a benign hemangioma. In view of the rarity of pericardial tumors, the present tumor is suspected to have undergone a transformation from benign hemangioma to malignant fibrosarcoma. (orig.)

  7. Quantitative assessment of Al-to-N bonding in dilute Al0.33Ga0.67As1-yNy

    International Nuclear Information System (INIS)

    Wagner, J.; Geppert, T.; Koehler, K.; Ganser, P.; Maier, M.

    2003-01-01

    A quantitative assessment of the group III-nitrogen bonding in low N-content Al 0.33 Ga 0.67 As 1-y N y with y≤0.04 has been performed, using vibrational mode Raman spectroscopy for the quantitative analysis of local bond formation in combination with energy dispersive x-ray analysis and secondary ion mass spectrometry for chemical analysis. Clear evidence is obtained for the preferential bonding of nitrogen to Al with one nitrogen atom being coordinated to, at the average, 3.4 Al neighbors. This strong preference for Al-to-N bond formation can be understood in terms of the much larger cohesive energy of the Al-N bond compared to the Ga-N chemical bond. In spite of this phase-separation-like formation of local Al-N complexes, the fundamental band gap and the E 1 /E 1 +Δ 1 band gaps show a continuous low-energy and high-energy shift, respectively, upon the addition of nitrogen as already known from dilute GaAsN

  8. SPECT in psychiatry; Die Bedeutung der Hirn-SPECT in der Psychiatrie

    Energy Technology Data Exchange (ETDEWEB)

    Kasper, S [Universitaetsklinik fuer Psychiatrie, Wien (Austria); Gruenwald, F [Bonn Univ. (Germany). Klinik fuer Nuklearmedizin; Danos, P [Psychiatrische Universitaetsklinik, Bonn (Germany); Walter, H [Universitaetsklinik fuer Psychiatrie, Wien (Austria); Klemm, E [Bonn Univ. (Germany). Klinik fuer Nuklearmedizin; Bruecke, T [Universitaetsklinik fuer Neurologie, Wien (Austria); Podreka, I [Universitaetsklinik fuer Neurologie, Wien (Austria); Biersack, H J [Bonn Univ. (Germany). Klinik fuer Nuklearmedizin

    1994-10-01

    In the last fifteen years different attempts have been undertaken to understand the biological basis of major psychiatric disorders. One important tool to determine patterns of brain dysfunction is single emission computed tomography (SPECT). Whereas SPECT investigations are already a valuable diagnostic instrument for the diagnosis of dementia of the Alzheimer Type (DAT) there have not been consistent findings that can be referred to as specific for any other particular psychiatric diagnostic entity. Nevertheless, SPECT studies have been able to demonstrate evidence of brain dysfunction in patients with schizophrenia, depression, anxiety disorders, and substance abuse in which other methods showed no clear abnormality of brain function. Our manuscript reviews the data which are currently available in the literature and stresses the need for further studies, especially for prediction and monitoring psychiatric treatment modalities. (orig.) [Deutsch] In den vergangenen 15 Jahren wurde durch verschiedene methodologische Ansaetze versucht, die biologischen Ursachen psychiatrischer Erkrankungen naeher zu erforschen. Als eine bedeutende Methode hat sich dabei die Single-Photonen-Emissions-Computertomographie (SPECT) herausgestellt. Waehrend die SPECT-Untersuchungen bereits Eingang in die Routinediagnostik bei Demenzen vom Alzheimer-Typ gefunden haben, konnten fuer weitere psychiatrische Erkrankungen noch keine eindeutigen Befunde etabliert werden. Mit der SPECT-Methode ist es jedoch gelungen, funktionelle Veraenderungen des Gehirns von psychiatrischen Erkrankungen darzustellen, wie z.B. Schizophrenie, Depression, Angsterkrankungen bzw. Substanzmissbrauch. In Forschungsprotokollen wird durch die SPECT-Methode versucht, abzuklaeren, inwieweit es moeglich ist, innerhalb der Erkrankungsentitaeten psychiatrischer Erkrankungen oder auch diese uebergreifend eine Subklassifizierung zu finden und evtl. Gehirnsysteme ausfindig zu machen, die mit einer spezifischen

  9. Clinical protocol for conducting a bone scintigraphy subsequent SPECT/CT examination

    International Nuclear Information System (INIS)

    Jovanovska, A.; Dimcheva, M.; Doldurova, M.

    2013-01-01

    Full text: Introduction: Like any nuclear medicine study, bone scintigraphy is a diagnostic procedure associated with intravenous injection of a radioactive isotope with low activity - radiopharmaceutical. But recently in clinical practice hybrid imaging methods such as SPECT/ CT (Single Photon Emission Tomography - Computed Tomography) has necessitated, as they provide comprehensive information about the function and structure of the studied organ. Materials and methods: In the Department of Nuclear Medicine in The Specialized Hospital for Active Treatment of Oncology Diseases in Sofia it is installed a two-detector SPECT/CT gamma camera Siemens Symbia T2, on which the whole range of nuclear medicine studies in oncology practice is held: bone scintigraphy, 99mTc - MIBI scintigraphy, Lymphoscintigraphy, somatostatin receptor scintigraphy, tireostsintigraphy with 131I/99mTc, dynamic nephroscintgraphy etc. The working algorithm upon choosing the clinical protocols, and setting the parameters for scanning are complied with the requirements and recommendations established by the nuclear medicine standard. The presented are results from studies of patients when after whole body bone scintigraphy, an additional SPECT/CT study was conducted for more accurate diagnostic and interpretation of the results. Results: Practical introduction of hybrid imaging methods require from technicians besides knowledge in working with radioactive sources and practical skills such as: the selection of the matrix size, number of projections, choice of trajectory - circular or elliptical, set the appropriate degree of rotation of the detector (180 or 360). Particularly important in the processing of MR images is the appropriate choice of algorithm of reconstruction: filtered backprojection or iterative reconstruction methods. In MR images processing there is no rule for the optimal filter, which is why the quality of the reconstructed image depends primarily on the experience of the operator

  10. Recognition of distinctive patterns of gallium-67 distribution in sarcoidosis

    International Nuclear Information System (INIS)

    Sulavik, S.B.; Spencer, R.P.; Weed, D.A.; Shapiro, H.R.; Shiue, S.T.; Castriotta, R.J.

    1990-01-01

    Assessment of gallium-67 ( 67 Ga) uptake in the salivary and lacrimal glands and intrathoracic lymph nodes was made in 605 consecutive patients including 65 with sarcoidosis. A distinctive intrathoracic lymph node 67 Ga uptake pattern, resembling the Greek letter lambda, was observed only in sarcoidosis (72%). Symmetrical lacrimal gland and parotid gland 67 Ga uptake (panda appearance) was noted in 79% of sarcoidosis patients. A simultaneous lambda and panda pattern (62%) or a panda appearance with radiographic bilateral, symmetrical, hilar lymphadenopathy (6%) was present only in sarcoidosis patients. The presence of either of these patterns was particularly prevalent in roentgen Stages I (80%) or II (74%). We conclude that simultaneous (a) lambda and panda images, or (b) a panda image with bilateral symmetrical hilar lymphadenopathy on chest X-ray represent distinctive patterns which are highly specific for sarcoidosis, and may obviate the need for invasive diagnostic procedures

  11. A small-animal imaging system capable of multipinhole circular/helical SPECT and parallel-hole SPECT

    International Nuclear Information System (INIS)

    Qian Jianguo; Bradley, Eric L.; Majewski, Stan; Popov, Vladimir; Saha, Margaret S.; Smith, Mark F.; Weisenberger, Andrew G.; Welsh, Robert E.

    2008-01-01

    We have designed and built a small-animal single-photon emission computed tomography (SPECT) imaging system equipped with parallel-hole and multipinhole collimators and capable of circular or helical SPECT. Copper-beryllium parallel-hole collimators suitable for imaging the ∼35 keV photons from the decay of 125 I have been built and installed to achieve useful spatial resolution over a range of object-detector distances and to reduce imaging time on our dual-detector array. To address the resolution limitations in the parallel-hole SPECT and the sensitivity and limited field of view of single-pinhole SPECT, we have incorporated multipinhole circular and helical SPECT in addition to expanding the parallel-hole SPECT capabilities. The pinhole SPECT system is based on a 110 mm diameter circular detector equipped with a pixellated NaI(Tl) scintillator array (1x1x5 mm 3 /pixel). The helical trajectory is accomplished by two stepping motors controlling the rotation of the detector-support gantry and displacement of the animal bed along the axis of rotation of the gantry. Results obtained in SPECT studies of various phantoms show an enlarged field of view, very good resolution and improved sensitivity using multipinhole circular or helical SPECT. Collimators with one, three and five, 1-mm-diameter pinholes have been implemented and compared in these tests. Our objective is to develop a system on which one may readily select a suitable mode of either parallel-hole SPECT or pinhole circular or helical SPECT for a variety of small animal imaging applications

  12. Polarization-engineered GaN/InGaN/GaN tunnel diodes

    International Nuclear Information System (INIS)

    Krishnamoorthy, Sriram; Nath, Digbijoy N.; Akyol, Fatih; Park, Pil Sung; Esposto, Michele; Rajan, Siddharth

    2010-01-01

    We report on the design and demonstration of polarization-engineered GaN/InGaN/GaN tunnel junction diodes with high current density and low tunneling turn-on voltage. Wentzel-Kramers-Brillouin calculations were used to model and design tunnel junctions with narrow band gap InGaN-based barrier layers. N-polar p-GaN/In 0.33 Ga 0.67 N/n-GaN heterostructure tunnel diodes were grown using molecular beam epitaxy. Efficient interband tunneling was achieved close to zero bias with a high current density of 118 A/cm 2 at a reverse bias of 1 V, reaching a maximum current density up to 9.2 kA/cm 2 . These results represent the highest current density reported in III-nitride tunnel junctions and demonstrate the potential of III-nitride tunnel devices for a broad range of optoelectronic and electronic applications.

  13. Radiation dose in cardiac SPECT/CT: An estimation of SSDE and effective dose

    International Nuclear Information System (INIS)

    Abdollahi, Hamid; Shiri, Isaac; Salimi, Yazdan; Sarebani, Maghsoud; Mehdinia, Reza; Deevband, Mohammad Reza; Mahdavi, Seied Rabi; Sohrabi, Ahmad; Bitarafan-Rajabi, Ahmad

    2016-01-01

    Aims: The dose levels for Computed Tomography (CT) localization and attenuation correction of Single Photon Emission Computed Tomography (SPECT) are limited and reported as Volume Computed Tomography Dose Index (CTDIvol) and Dose-Length Product (DLP). This work presents CT dose estimation from Cardiac SPECT/CT based on new American Association of Physicists in Medicine (AAPM) Size Specific Dose Estimation (SSDE) parameter, effective dose, organ doses and also emission dose from nuclear issue. Material and methods: Myocardial perfusion SPECT/CT for 509 patients was included in the study. SSDE, effective dose and organ dose were calculated using AAPM guideline and Impact-Dose software. Data were analyzed using R and SPSS statistical software. Spearman-Pearson correlation test and linear regression models were used for finding correlations and relationships among parameters. Results: The mean CTDIvol was 1.34 mGy ± 0.19 and the mean SSDE was 1.7 mGy ± 0.16. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The spearman test showed that correlation between body size and organ doses is significant except thyroid and red bone marrow. CTDIvol was strongly dependent on patient size, but SSDE was not. Emission dose was strongly dependent on patient weight, but its dependency was lower to effective diameter. Conclusion: The dose parameters including CTDIvol, DLP, SSDE, effective dose values reported here are very low and below the reference level. This data suggest that appropriate CT acquisition parameters in SPECT/CT localization and attenuation correction are very beneficial for patients and lowering cancer risks.

  14. Radiation dose in cardiac SPECT/CT: An estimation of SSDE and effective dose

    Energy Technology Data Exchange (ETDEWEB)

    Abdollahi, Hamid, E-mail: Hamid_rbp@yahoo.com [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Shiri, Isaac [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Salimi, Yazdan [Biomedical Engineering and Medical Physics Department, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of); Sarebani, Maghsoud; Mehdinia, Reza [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Deevband, Mohammad Reza [Biomedical Engineering and Medical Physics Department, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of); Mahdavi, Seied Rabi [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Radiation Biology Research Center, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Sohrabi, Ahmad [Department of Biostatistics, School of Public Health, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Bitarafan-Rajabi, Ahmad, E-mail: bitarafan@hotmail.com [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Department of Nuclear Medicine, Rajaei Cardiovascular, Medical and Research Center, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of)

    2016-12-15

    Aims: The dose levels for Computed Tomography (CT) localization and attenuation correction of Single Photon Emission Computed Tomography (SPECT) are limited and reported as Volume Computed Tomography Dose Index (CTDIvol) and Dose-Length Product (DLP). This work presents CT dose estimation from Cardiac SPECT/CT based on new American Association of Physicists in Medicine (AAPM) Size Specific Dose Estimation (SSDE) parameter, effective dose, organ doses and also emission dose from nuclear issue. Material and methods: Myocardial perfusion SPECT/CT for 509 patients was included in the study. SSDE, effective dose and organ dose were calculated using AAPM guideline and Impact-Dose software. Data were analyzed using R and SPSS statistical software. Spearman-Pearson correlation test and linear regression models were used for finding correlations and relationships among parameters. Results: The mean CTDIvol was 1.34 mGy ± 0.19 and the mean SSDE was 1.7 mGy ± 0.16. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The spearman test showed that correlation between body size and organ doses is significant except thyroid and red bone marrow. CTDIvol was strongly dependent on patient size, but SSDE was not. Emission dose was strongly dependent on patient weight, but its dependency was lower to effective diameter. Conclusion: The dose parameters including CTDIvol, DLP, SSDE, effective dose values reported here are very low and below the reference level. This data suggest that appropriate CT acquisition parameters in SPECT/CT localization and attenuation correction are very beneficial for patients and lowering cancer risks.

  15. Standardization of {sup 67}Ga, {sup 51}Cr and {sup 55}Fe by live-timed anti-coincidence counting with extending dead time

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Carlos J. da [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI), Instituto de Radioprotecao e Dosimetria (IRD), Comissao Nacional de Energia Nuclear - CNEN, Av. Salvador Allende, s/n0-Recreio, CEP 22780-160 Rio de Janeiro (Brazil) and Laboratorio de Instrumentacao Nuclear (LIN/PEN/COPPE/UFRJ), Caixa Postal 68590, CEP 21945-970 Rio de Janeiro (Brazil)], E-mail: Carlos@ird.gov.br; Iwahara, A.; Poledna, R.; Bernardes, E.M. de O; Prinzio, M.A.R.R. de [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI), Instituto de Radioprotecao e Dosimetria (IRD), Comissao Nacional de Energia Nuclear - CNEN, Av. Salvador Allende, s/n0-Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Lopes, Ricardo T. [Laboratorio de Instrumentacao Nuclear (LIN/PEN/COPPE/UFRJ), Caixa Postal 68590, CEP 21945-970 Rio de Janeiro (Brazil)

    2008-02-15

    In this work, the activity standardization of {sup 51}Cr, {sup 55}Fe and {sup 67}Ga by live-timed anti-coincidence counting with extending dead time is described. The difficulties of the method, the uncertainties of the results of the measurements and the comparison of these results with others measurement methods are discussed.

  16. Indeterminate lesions on planar bone scintigraphy in lung cancer patients: SPECT, CT or SPECT-CT?

    International Nuclear Information System (INIS)

    Sharma, Punit; Kumar, Rakesh; Singh, Harmandeep; Bal, Chandrasekhar; Malhotra, Arun; Julka, Pramod Kumar; Thulkar, Sanjay

    2012-01-01

    The objective of the present study was to compare the role of single photon emission computed tomography (SPECT), computed tomography (CT) and SPECT-CT of selected volume in lung cancer patients with indeterminate lesions on planar bone scintigraphy (BS). The data of 50 lung cancer patients (53 ± 10.3 years; range 30-75; male/female 38/12) with 65 indeterminate lesions on planar BS (January 2010 to November 2010) were retrospectively evaluated. All of them underwent SPECT-CT of a selected volume. SPECT, CT and SPECT-CT images were independently evaluated by two experienced readers (experience in musculoskeletal imaging, including CT: 5 and 7 years) in separate sessions. A scoring scale of 1 to 5 was used, in which 1 is definitely metastatic, 2 is probably metastatic, 3 is indeterminate, 4 is probably benign and 5 is definitely benign. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for each modality, taking a score ≤2 as metastatic. With receiver operating characteristic (ROC) curve analysis, areas under the curve (AUC) were calculated for each modality and compared. Clinical and imaging follow-up and/or histopathology were taken as reference standard. For both readers SPECT was inferior to CT (P = 0.004, P = 0.022) and SPECT-CT (P = 0.003, P = 0.037). However, no significant difference was found between CT and SPECT-CT for reader 1 (P = 0.847) and reader 2 (P = 0.592). The findings were similar for lytic as well as sclerotic lesions. Moderate inter-observer agreement was seen for SPECT images (κ = 0.426), while almost perfect agreement was seen for CT (κ = 0.834) and SPECT-CT (κ = 0.971). CT alone and SPECT-CT are better than SPECT for accurate characterisation of indeterminate lesions on planar BS in lung cancer patients. CT alone is not inferior to SPECT-CT for this purpose and might be preferred because of shorter acquisition time and wider availability. (orig.)

  17. Evaluation of epileptogenic focus in temporal lobe: correlation between ictal brain SPECT, magnetic resonance imaging and magnetic resonance spectroscopy; Avaliacao de foco epileptogenico do lobo temporal: correlacao entre SPECT ictal, ressonancia magnetica e ressonancia magnetica com espectroscopia de protons

    Energy Technology Data Exchange (ETDEWEB)

    Diegues, Maria Elena Martins [Hospital Universitario Clementino Fraga Filho, Rio de Janeiro, RJ (Brazil). Servico de Medicina Nuclear]. E-mail: emartyns@terra.com.br; Pellini, Marcos Pinto; Alves-Leon, Soniza Vieira [Universidade Federal, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina; Domingues, Romeu Cortes [Clinica de Diagnostico por Imagem (CDPI), Rio de Janeiro, RJ (Brazil)

    2004-02-01

    The purpose of this study was to determine the degree of concordance between radiological and radioisotopic methods and, if positive, to evaluate the usefulness of ictal SPECT in the localization of the epileptogenic focus. Ictal brain SPECT, magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) were performed on six patients with refractory temporal lobe epilepsy. Ictal SPECT was performed after withdrawal of the anti-epileptogenic drugs during video-EEG monitoring, using {sup 99m}Tc-ECD, administered to patients at the time of the ictus. MRI was performed in T1, T2 and FLAIR sequences and MRS was obtained using the PRESS technique, with a single voxel positioned in both hippocampi. The statistical analysis included the determination of the values of Kappa (k), standard error (se) and significance level (p) for the lateralization of the ictal focus. The analysis of all findings was based on EEG localization of the ictal discharge, seizure duration (109-280 s; 152 s average) and time of radiotracer injection (30-262 s; 96 s average). We obtained correlated data in four patients (67 per cent) and values of k = 0.67, se = 0.38, and p 0.041. We concluded that there is a concordance between ictal SPECT, MRI and MRS data and the usefulness of the radioisotopic procedure is related to a non diagnostic EEG and when there is a discordant or misleading diagnosis after a comparative analysis of EEG and MRS. (author)

  18. Sensitivity and specificity of Ga-67 pulmonary scans for the detection of p. carinii pneumonitis in patients with the acquired immunodefficiency syndrome and pulmonary symptoms

    International Nuclear Information System (INIS)

    Hattner, R.S.; Sollitto, R.A.; Golden, J.A.; Coleman, D.L.; Okerlund, M.D.

    1984-01-01

    Acquired immunodeficiency syndrome (AIDS) is a severe disorder of cellular immunity of obscure etiology. Since its original recognition in 1981 the incidence of AIDS has doubled in each of the succeeding six months. The most common causes of death in AIDS are Kaposi's sarcoma and p. carinii pneumonia (PCP). The latter is treatable if diagnosed early, and AIDS patients (pts) may suffer recurrent episodes of PCP. Since the invasive technique of fiberoptic bronchoscopy with transbronchial biopsy, brushing, and bronchialveolar lavage are necessary for diagnosis and follow-up a noninvasive method of categorizing which AIDS pts require this procedure would be most welcome. Twenty-one pts with the syndrome of AIDS and pulmonary symptoms underwent Ga-67 scans of the thoracic region, and fibroptic bronchoscopy with washings, and brush and transbronchial biopsy. Pulmonary activity was graded in a blinded fashion by three experienced observers as follows: 1, less than, or equal to adjacent soft tissues; 2, greater than adjacent soft tissues, but less than liver; 3, equal to liver; 4, greater than liver. Eleven pts had documented PCP, and the remaining ten had non-specific pulmonary inflammation, or other, in some cases, putative, infections. The sensitivity and specificity of Ga-67 scans ≥ grade 3 was 100% and 90% respectively. These results suggests a useful role for graded Ga-67 scans in AIDS pts with pulmonary symptoms, permitting selection of pts with a high risk of PCP for further mandatory invasive investigation of this otherwise usually fatal disease

  19. Structure and magnetoresistance of La0.67Ca0.33MnO3 films grown coherently on (001)NdGaO3

    International Nuclear Information System (INIS)

    Bojkov, Yu.A.; Danilov, V.A.; Bojkov, A.Yu.

    2003-01-01

    The (001) La 0.67 Ca 0.33 MnO 3 films, 40-120 nm thick, grown through the method of the laser evaporation on the (001)NdGaO 3 , are studied. The crystalline lattice parameters, measured for the La 0.67 Ca 0.33 MnO 3 film in the substrate plane α parallel = 3.851 A and along the normal to its surface α perpendicular = 3.850 A practically coincide with the parameter of the pseudocubic elementary cell of the neodymium gallate. The elementary cell volume in the La 0.67 Ca 0.33 MnO 3 film was insignificantly lesser than the corresponding value for the stoichiometric voluminous samples. The position of the maximum on the specific resistance dependence on the temperature did not depend on the La 0.67 Ca 0.33 MnO 3 film thickness. The maximum values of the negative magnetoresistance (MR ≅ 0.25, H = 0.4 T) for the La 0.67 Ca 0.33 MnO 3 films were observed at the temperatures of 239-244 K [ru

  20. Diagnostic value of myocardial perfusion SPECT in the prediction of restenosis after coronary artery bypass graft surgery

    International Nuclear Information System (INIS)

    Paeng, J. C.; Lee, D. S.; Kang, W. J.; Kim, K. B.; Chung, J. K.; Lee, M. C.

    2002-01-01

    Myocardial SPECT has been reported to be sensitive in the detection of restenosis after revascularization. However, the diagnostic value is not well established in bypass graft surgery (CABG), due to significant influences of characteristics of graft vessels and the time interval between CABG and the SPECT. In this study, we evaluated the diagnostic value of myocardial SPECT for the restenosis after CABG. A total of 160 patients with coronary artery disease (M:F=118:42, 60±8 yr) who had undergone CABG were included. Rest T1-201/ dipyridamole stress Tc-99m-MIBI SPECT was performed 3 months (103±16 days) after CABG. Segmental perfusion was quantified using a 20-segment model, and segments of reversible perfusion defect (REV) were defined. Follow-up coronary angiography was performed 1 year (397±104 days) after CABG. The segments of REV were compared between arterial and venous graft groups. And the diagnostic power of 3-month SPECT was evaluated for the prediction of restenosis. On the 3-month SPECT, 620 segments showed REV. The segments of REV were 37% of artery-grafted segments and 36% of vein-grafted segments (p=n.s.). On 1-year coronary angiography, 113 graft vessels (28%) showed restenosis. The overall sensitivity and specificity of REV on 3-month SPECT for the prediction of restenosis were 46% and 67%, respectively, but 52% and 68%, in artery-graft group. REV detected on 3-month SPECT has a predictive value, especially, high specificity for the prediction of restenosis after CABG, which was more definite in artery-graft group

  1. Gallium-67 imaging in pericarditis secondary to tuberculosis and histoplasmosis

    International Nuclear Information System (INIS)

    Taillefer, R.; Lemieux, R.J.; Picard, D.; Dupras, G.

    1981-01-01

    In recent years, many cases of Ga-67 uptake by the heart have been reported. One such case involved a patient with tuberculous pericarditis. Recently, a patient was referred to us for the investigation of a fever of unknown origin. A Ga-67 scan was performed and showed an intense uptake by the pericardium. The final diagnosis was pericarditis secondary to mediastinal lymph node involvement with tuberculosis and histoplasmosis

  2. Measurements of {sup 67}Ga production cross section induced by protons on {sup nat}Zn in the low energy range from 1.678 to 2.444 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Wachter, J.A., E-mail: javier.wachter@utem.cl [Departamento de Física, Facultad de Ciencias Naturales, Matemática y del Medio Ambiente, Universidad Tecnológica Metropolitana, Santiago 7800002 (Chile); Miranda, P.A. [Departamento de Física, Facultad de Ciencias Naturales, Matemática y del Medio Ambiente, Universidad Tecnológica Metropolitana, Santiago 7800002 (Chile); Morales, J.R.; Cancino, S.A. [Departamento de Física, Facultad de Ciencias, Universidad de Chile, Casilla 653, Santiago (Chile); Correa, R. [Departamento de Física, Facultad de Ciencias Naturales, Matemática y del Medio Ambiente, Universidad Tecnológica Metropolitana, Santiago 7800002 (Chile)

    2015-02-01

    The experimental production cross section for the reaction {sup nat}Zn(p,x){sup 67}Ga has been measured in the energy range from 1.678 to 2.444 MeV. The methodology used in this work is based on characteristic X-ray emitted after irradiation by the daughter nuclei that decays by electron capture (EC) and the use of a complementary PIXE experiment. By doing so, expressions needed to determine cross section values are simplified since experimental factors such as geometric setup and an detector efficiency are avoided. {sup 67}Ga is a radionuclide particularly suited for this method since it decays by electron capture in 100% and the subsequent characteristic X-ray emission is easily detected. Natural zinc targets were fabricated by PVD technique and afterwards their thicknesses were determined by Rutherford Backscattering Spectrometry. Cross sections measurements were carried out by using the Van de Graaff accelerator located at Faculty of Sciences, University of Chile. It was found that our data for the {sup nat}Zn(p,x){sup 67}Ga reaction are, in general, in good agreement when compared to existing experimental data and to those calculated ALICE/ASH nuclear code. On the other hand, values predicted by Talys-1.6 are showing systematically lower magnitudes than our measured data.

  3. Hybrid InGaAs quantum well-dots nanostructures for light-emitting and photo-voltaic applications.

    Science.gov (United States)

    Mintairov, S A; Kalyuzhnyy, N A; Lantratov, V M; Maximov, M V; Nadtochiy, A M; Rouvimov, Sergei; Zhukov, A E

    2015-09-25

    Hybrid quantum well-dots (QWD) nanostructures have been formed by deposition of 7-10 monolayers of In0.4Ga0.6As on a vicinal GaAs surface using metal-organic chemical vapor deposition. Transmission electron microscopy, photoluminescence and photocurrent analysis have shown that such structures represent quantum wells comprising three-dimensional (quantum dot-like) regions of two kinds. At least 20 QWD layers can be deposited defect-free providing high gain/absorption in the 0.9-1.1 spectral interval. Use of QWD media in a GaAs solar cell resulted in a photocurrent increment of 3.7 mA cm(-2) for the terrestrial spectrum and by 4.1 mA cm(-2) for the space spectrum. Diode lasers based on QWD emitting around 1.1 μm revealed high saturated gain and low transparency current density of about 15 cm(-1) and 37 A cm(-2) per layer, respectively.

  4. A comparative study of attenuation correction algorithms in single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Murase, Kenya; Itoh, Hisao; Mogami, Hiroshi; Ishine, Masashiro; Kawamura, Masashi; Iio, Atsushi; Hamamoto, Ken

    1987-01-01

    A computer based simulation method was developed to assess the relative effectiveness and availability of various attenuation compensation algorithms in single photon emission computed tomography (SPECT). The effect of the nonuniformity of attenuation coefficient distribution in the body, the errors in determining a body contour and the statistical noise on reconstruction accuracy and the computation time in using the algorithms were studied. The algorithms were classified into three groups: precorrection, post correction and iterative correction methods. Furthermore, a hybrid method was devised by combining several methods. This study will be useful for understanding the characteristics limitations and strengths of the algorithms and searching for a practical correction method for photon attenuation in SPECT. (orig.)

  5. Method of determination of radiochemical purity of gallium-67 citrate injection

    International Nuclear Information System (INIS)

    Wang Quanji

    1985-01-01

    A simple method is used to compare the effect of five developing agents on the radiochemical purity of neutral products of 67 GaCit and on Rsub(f) values. Two preferable developing agents are recommended as suitable for the identification of 67 GaCit injection in its production. The effect of six pH values of different developing agents on radiochemical purity, Rsub(f) and chromatogram are compared for the neutral products. The results of the experiments show that the ascending paper chromatography with 1:2:4 pyridine/ethanol/water and 85:15 methanol/water is preferable for the determination of the radiochemical purity of 67 GaCit. The other developing agents also can be used if there are not any impurities except gallium radioisotopes

  6. Applications of SPECT / CT at the Institute of Nephrology

    International Nuclear Information System (INIS)

    Zayas Crespo, Francisco; Batlle Leal, Fernando; Mesa Dueñas, Niurka

    2016-01-01

    The main applications of SPECT-CT in the diagnosis of various diseases, as well as the experiences gained from the operation of this hybrid system are described. To date we have studied more than 100 patients from different hospitals in the capital and other nearby provinces, including. Including major diseases: kidney, bone, oncological and endocrine. So far, the results achieved have enabled diagnostic evaluation of higher accuracy and detail, even improving in a significant number of patients the initial diagnosis or modifying this fully. (author)

  7. Prognostic value of SPECT in newly diagnosed symptomatic west syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Goto, Megumi; Suzuki, Yasuhiro; Kato, Tomomi; Futagi, Yasuyuki [Osaka Medical Center and Research Inst. for Maternal and Child Health, Izumi (Japan)

    1999-07-01

    In 19 cases with newly diagnosed symptomatic West syndrome, we assessed interictal regional cerebral blood flow (rCBF) before ACTH therapy with single photon emission computed tomography (SPECT). Based on the SPECT findings, we divided these cases into 3 groups: normal rCBF (Group A, 7 cases), abnormal rCBF corresponding to cerebral lesions on MRI and CT (Group B, 6 cases), and abnormal rCBF in areas different from lesions on MRI and CT (Group C, 6 cases). We compared clinical features, response to initial treatment, and short-term outcome among these 3 groups. No significant differences were found in clinical characteristics (sex, age of onset, prior seizures before onset of spasms, EEG findings). Four cases in Group B (67%) and 5 in Group C (83%) showed complete cessation of spasms after initial treatment (high dose vitamin B{sub 6}{yields}zonisamide{yields}ACTH therapy), while in Group A only 2 patients (29%, p>0.05; compared to Group B or Group C) responded. Although not statistically significant, short-term prognosis (both seizures and development) after a mean follow-up of 2 years and 8 months was also worst in Group A. Our results suggest that normal SPECT findings may be predictive of unfavorable prognosis in infants with symptomatic West syndrome. (author)

  8. Deterministic and stochastic approach for safety and reliability optimization of captive power plant maintenance scheduling using GA/SA-based hybrid techniques: A comparison of results

    International Nuclear Information System (INIS)

    Mohanta, Dusmanta Kumar; Sadhu, Pradip Kumar; Chakrabarti, R.

    2007-01-01

    This paper presents a comparison of results for optimization of captive power plant maintenance scheduling using genetic algorithm (GA) as well as hybrid GA/simulated annealing (SA) techniques. As utilities catered by captive power plants are very sensitive to power failure, therefore both deterministic and stochastic reliability objective functions have been considered to incorporate statutory safety regulations for maintenance of boilers, turbines and generators. The significant contribution of this paper is to incorporate stochastic feature of generating units and that of load using levelized risk method. Another significant contribution of this paper is to evaluate confidence interval for loss of load probability (LOLP) because some variations from optimum schedule are anticipated while executing maintenance schedules due to different real-life unforeseen exigencies. Such exigencies are incorporated in terms of near-optimum schedules obtained from hybrid GA/SA technique during the final stages of convergence. Case studies corroborate that same optimum schedules are obtained using GA and hybrid GA/SA for respective deterministic and stochastic formulations. The comparison of results in terms of interval of confidence for LOLP indicates that levelized risk method adequately incorporates the stochastic nature of power system as compared with levelized reserve method. Also the interval of confidence for LOLP denotes the possible risk in a quantified manner and it is of immense use from perspective of captive power plants intended for quality power

  9. In vivo and in vitro evaluation of dota-lanreotide radiolabelled with gallium-67; Avaliacao in vivo e in vitro do dota-lanreotideo radiomarcado com galio-67

    Energy Technology Data Exchange (ETDEWEB)

    Aldegheri, Eliane Bernardes

    2005-07-01

    One of the refinements of modern Nuclear Medicine is the capacity of providing dynamic and kinetics images of the administered radiopharmaceutical, reproducing its transport mechanism, action sites, receptor binding and excretion route. With the continues technological advances new radiopharmaceuticals have been developed in order to express higher specificity and with higher characters of affinity between receptor/complex. One radiopharmaceutical is formed by a reagent or bio molecule that has in its structure a radioisotope, that has the objectives of carrying it to the organs of affinity or to benign or malign tumoral process. Somatostatin inhibits the growing and proliferation of several tumoral cells. Somatostatin analogs bind to somatostatic receptors that are expressed in different kind of neoplasia DOTA-LANREOTIDE (DOTALAN) is an octapeptide analog to somatostatin. The interest of labeling the bio conjugate with gallium-67 in Nuclear Medicine comes from its physical, chemical and biological properties. Besides its gamma radiation, useful in the diagnosis of inflammation and infection foci, {sup 67}Ga emits Auger electrons (0.1 - 8 keV) and conversion electrons (80 - 90 keV), making it attractive to internal radiotherapy if the vectors used to lead the radionuclide to the tumoral cell are internalized. The objective of this work was to develop a methodology of labelling DOTA-LANREOTIDE with {sup 67}Ga, optimizing the labelling variables and its quality control. The novelty aspect was the comparison between labeling with national and imported {sup 67}Ga, in its original and purified forms. The purification of {sup 67}Ga was essential to reach yields higher than 90%. The radiolabelled bio conjugate peptides must be free of metallic contaminants that could compete in the labeling process. The following procedure was established after studying the labeling parameters: mass of peptide of 10 {mu}g (6nmol), pH5, final reaction volume of 170 {mu}L of the labelled

  10. Diagnostic performance of Tc-99m HMPAO SPECT for early and late onset Alzheimer's disease. A clinical evaluation of linearization correction

    International Nuclear Information System (INIS)

    Mitsumoto, Tatsuya; Sakaguchi, Yuichi; Morishita, Junji; Sasaki, Masayuki; Ohya, Nobuyoshi; Abe, Koichiro; Ichimiya, Atsushi; Kiyota, Aya

    2009-01-01

    This study examined the influence of linearization correction (LC) on brain perfusion single-photon emission computed tomography (SPECT) for the diagnosis of Alzheimer's disease (AD). The early onset group (<65 years old) consisted of 10 patients with AD, and the late onset group (≥65 years old) of 13 patients with AD. Age-matched controls included seven younger and seven older normal volunteers. Tc-99m hexamethyl propyleneamine oxine (HMPAO) SPECT images were reconstructed with or without LC [LC (+) or LC (-)] and a statistical analysis was performed using a three-dimensional stereotactic surface projection (3D-SSP). In addition, a fully automatic diagnostic system was developed, which calculated the proportion of the number of abnormal pixels in the superior and inferior parietal lobule, as well as in the precuneus and posterior cingulate gyrus. The areas under the receiver-operating characteristic curve (AUCs) of the early onset group for conventional axial SPECT images, SPECT+3D-SSP images and the fully automatic diagnostic system were 0.71, 0.88, and 0.92 in LC (-) and 0.67, 0.85, and 0.91 in LC (+), respectively. The AUCs of the late onset group were 0.50, 0.61, and 0.79 in LC (-) and 0.49, 0.67, and 0.85 in LC (+), respectively. LC on Tc-99m HMPAO SPECT did not significantly influence the diagnostic performance for differentiating between AD and normal controls in either early or late onset AD. Further examination with individuals suffering from very mild dementia is, therefore, expected to elucidate the effect of LC on minimally hypoperfused areas. (author)

  11. Serial SPECT in children with partial epilepsy

    International Nuclear Information System (INIS)

    Hosoya, Machiko; Ushiku, Hideo

    1995-01-01

    We performed serial single-photon emission CT (SPECT) with N-isopropyl-p-( 123 I)-Iodoamphetamine to measure the regional cerebral blood flow (rCBF) in 15 children with partial epilepsy. SPECT showed focal changes in 14 cases. Ten cases had abnormalities in the initial SPECT and another four cases in the second test. The cases with normal rCBF in initial SPECT had been tested in an early phase after the onset, and then decreased rCBF were observed in the second SPECT. The cases with both abnormal rCBF in the initial SPECT and improved rCBF in the second SPECT showed good prognosis in clinico-electrophysiological evolutions. In cases with abnormal changes of rCBF in the second SPECT, clinical prognosis was found to be not so good. These findings suggest that serial SPECT may be used to follow the course of epilepsy. (author)

  12. Evaluation of Ga-DOTA-(D-Asp)n as bone imaging agents: D-aspartic acid peptides as carriers to bone.

    Science.gov (United States)

    Ogawa, Kazuma; Ishizaki, Atsushi; Takai, Kenichiro; Kitamura, Yoji; Makino, Akira; Kozaka, Takashi; Kiyono, Yasushi; Shiba, Kazuhiro; Odani, Akira

    2017-10-25

    67 Ga-DOTA-(L-Asp) 11 and 67 Ga-DOTA-(L-Asp) 14 , which have been developed as bone imaging agents, showed a high accumulation in bone and a rapid blood clearance in mice. However, peptides composed of D-amino acids are more stable in vivo than those composed of their L-equivalents. In this study, 67 Ga-DOTA-(D-Asp) n (n = 2, 5, 8, 11, or 14) were synthesized using the Fmoc-based solid-phase methodology and evaluated. In hydroxyapatite binding assay, binding of 67 Ga-DOTA-(D-Asp) n tended to increase with increasing length of the amino acid chain. 67 Ga-DOTA-(D-Asp) 11 and 67 Ga-DOTA-(D-Asp) 14 caused a high accumulation of radioactivity in the bones of the mice. However, the results for 67 Ga-DOTA-(D-Asp) n and 67 Ga-DOTA-(L-Asp) n were comparable. In urine analyses, the proportion of intact complex after injection of 67 Ga-DOTA-(D-Asp) 14 was significantly higher than that of 67 Ga-DOTA-(L-Asp) 14 . Although 67 Ga-DOTA-(D-Asp) 14 was more stable than 67 Ga-DOTA-(L-Asp) 14 , the properties of 67 Ga-DOTA-(D-Asp) n and 67 Ga-DOTA-(L-Asp) n as bone imaging agents may be comparable.

  13. Automatic lung segmentation in functional SPECT images using active shape models trained on reference lung shapes from CT.

    Science.gov (United States)

    Cheimariotis, Grigorios-Aris; Al-Mashat, Mariam; Haris, Kostas; Aletras, Anthony H; Jögi, Jonas; Bajc, Marika; Maglaveras, Nicolaos; Heiberg, Einar

    2018-02-01

    Image segmentation is an essential step in quantifying the extent of reduced or absent lung function. The aim of this study is to develop and validate a new tool for automatic segmentation of lungs in ventilation and perfusion SPECT images and compare automatic and manual SPECT lung segmentations with reference computed tomography (CT) volumes. A total of 77 subjects (69 patients with obstructive lung disease, and 8 subjects without apparent perfusion of ventilation loss) performed low-dose CT followed by ventilation/perfusion (V/P) SPECT examination in a hybrid gamma camera system. In the training phase, lung shapes from the 57 anatomical low-dose CT images were used to construct two active shape models (right lung and left lung) which were then used for image segmentation. The algorithm was validated in 20 patients, comparing its results to reference delineation of corresponding CT images, and by comparing automatic segmentation to manual delineations in SPECT images. The Dice coefficient between automatic SPECT delineations and manual SPECT delineations were 0.83 ± 0.04% for the right and 0.82 ± 0.05% for the left lung. There was statistically significant difference between reference volumes from CT and automatic delineations for the right (R = 0.53, p = 0.02) and left lung (R = 0.69, p automatic quantification of wide range of measurements.

  14. Abnormal splenic uptake of gallium-67 citrate in a case of infectious mononucleosis

    International Nuclear Information System (INIS)

    Campeau, R.J.; LaCorte, W.S.

    1985-01-01

    A case of fever of undetermined origin (FUO) demonstrated abnormal intense concentration of Ga-67 citrate in the spleen. Initial workup demonstrated two negative mono spot tests for infectious mononucleosis (IM) but, on hospital day 2, a repeat mono test was positive. The diagnosis was subsequently confirmed by rising heterophilic antibody titers. Six weeks after hospital discharge, repeat Ga-67 citrate imaging demonstrated absence of abnormal splenic activity. To our knowledge, this phenomenon has not been previously described in IM. In the appropriate clinical setting, intense splenic uptake of Ga-67 should alert the clinician to include the possibility of IM in the differential diagnosis

  15. SPECT in psychiatry

    International Nuclear Information System (INIS)

    Barocka, A.; Feistel, H.; Ebert, D.; Lungershausen, E.

    1993-01-01

    This review presents Single Photon Emission Computed Tomography (SPECT) as a powerful tool for clinical use and research in psychiatry. Its focus is on regional cerebral blood flow, measured with technetium labelled HMPAO. In addition, first results with brain receptor imaging, concerning dopamin-D 2 and benzodiazepine receptors, are covered. Due to major improvements in image quality, and impressive number of results has been accumulated in the past three years. The authors caution against using SPECT results as markers for disease entities. A finding like 'hypofrontality' is considered typical of a variety of mental disorders. Clearly both, more experience with SPECT and contributions from psychopathology, are needed. (orig.) [de

  16. Brain SPECT in children

    International Nuclear Information System (INIS)

    Guyot, M.; Baulieu, J.L.

    1996-01-01

    Brain SPECT in child involves specific trends regarding the patient cooperation, irradiation, resolution and especially interpretation because of the rapid scintigraphic modifications related to the brain maturation. In a general nuclear medicine department, child brain SPECT represents about 2 % of the activity. The choice indications are the perfusion children: thallium and MIBI in brain tumours, pharmacological and neuropsychological interventions. In the future, brain dedicated detectors and new radiopharmaceuticals will promote the development of brain SPECT in children. (author)

  17. Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology

    Science.gov (United States)

    Erlandsson, Kjell; Kacperski, Krzysztof; van Gramberg, Dean; Hutton, Brian F.

    2009-05-01

    D-SPECT (Spectrum Dynamics, Israel) is a novel SPECT system for cardiac perfusion studies. Based on CZT detectors, region-centric scanning, high-sensitivity collimators and resolution recovery, it offers potential advantages over conventional systems. A series of measurements were made on a β-version D-SPECT system in order to evaluate its performance in terms of energy resolution, scatter fraction, sensitivity, count rate capability and resolution. Corresponding measurements were also done on a conventional SPECT system (CS) for comparison. The energy resolution of the D-SPECT system at 140 keV was 5.5% (CS: 9.25%), the scatter fraction 30% (CS: 34%), the planar sensitivity 398 s-1 MBq-1 per head (99mTc, 10 cm) (CS: 72 s-1 MBq-1), and the tomographic sensitivity in the heart region was in the range 647-1107 s-1 MBq-1 (CS: 141 s-1 MBq-1). The count rate increased linearly with increasing activity up to 1.44 M s-1. The intrinsic resolution was equal to the pixel size, 2.46 mm (CS: 3.8 mm). The average reconstructed resolution using the standard clinical filter was 12.5 mm (CS: 13.7 mm). The D-SPECT has superior sensitivity to that of a conventional system with similar spatial resolution. It also has excellent energy resolution and count rate characteristics, which should prove useful in dynamic and dual radionuclide studies.

  18. Brain SPECT in childhood

    International Nuclear Information System (INIS)

    Tranquart, F.; Saliba, E.; Prunier, C.; Baulieu, F.; Besnard, J.C.; Guilloteau, D.; Baulieu, J.L.

    2001-01-01

    The modalities and the indications of perfusion and neurotransmission SPECT in childhood are presented. The perfusion as well as neurotransmission tracers have not yet authorization for use in children; they have to be used by prescription of magistral preparation or in research protocols. The radioprotection rules have to be strictly respected. The most frequent indication of perfusion SPECT is pharmacologically resistant epilepsy; the ictal SPECT before surgery allows the localization of the epileptogenic focus. Other indications are relevant in the prognosis of neonatal anoxia and encephalitis. In psychiatric disorders, especially in autism, the interest is the physiopathological approach of the brain dysfunctions. The neurotransmission SPECT is emerging as a consequence of the development of new radiotracer, as the dopaminergic system ligands. The decrease of the dopamine D2 receptors in the striatum can be imaged and quantified in the neonate. The lesions of dopamine system seem to be a consequence of the neonatal hypoxia-ischemia and it is predictive of motor sequelae. Brain SPECT should become a routine examination in child neurologic and psychiatric disorders. (authors)

  19. Comparison of two different segmentation methods on planar lung perfusion scan with reference to quantitative value on SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Min Seok; Kang, Yeon Koo; Ha, Seung Gyun [Dept. of Nuclear Medicine, Seoul National University Hospital, Seoul (Korea, Republic of); and others

    2017-06-15

    Until now, there was no single standardized regional segmentation method of planar lung perfusion scan. We compared planar scan based two segmentation methods, which are frequently used in the Society of Nuclear Medicine, with reference to the lung perfusion single photon emission computed tomography (SPECT)/computed tomography (CT) derived values in lung cancer patients. Fifty-five lung cancer patients (male:female, 37:18; age, 67.8 ± 10.7 years) were evaluated. The patients underwent planar scan and SPECT/CT after injection of technetium-99 m macroaggregated albumin (Tc-99 m-MAA). The % uptake and predicted postoperative percentage forced expiratory volume in 1 s (ppoFEV1%) derived from both posterior oblique (PO) and anterior posterior (AP) methods were compared with SPECT/CT derived parameters. Concordance analysis, paired comparison, reproducibility analysis and spearman correlation analysis were conducted. The % uptake derived from PO method showed higher concordance with SPECT/CT derived % uptake in every lobe compared to AP method. Both methods showed significantly different lobar distribution of % uptake compared to SPECT/CT. For the target region, ppoFEV1% measured from PO method showed higher concordance with SPECT/CT, but lower reproducibility compared to AP method. Preliminary data revealed that every method significantly correlated with actual postoperative FEV1%, with SPECT/CT showing the best correlation. The PO method derived values showed better concordance with SPECT/CT compared to the AP method. Both PO and AP methods showed significantly different lobar distribution compared to SPECT/CT. In clinical practice such difference according to different methods and lobes should be considered for more accurate postoperative lung function prediction.

  20. Prospective Study of 68Ga-DOTATATE Positron Emission Tomography/Computed Tomography for Detecting Gastro-Entero-Pancreatic Neuroendocrine Tumors and Unknown Primary Sites.

    Science.gov (United States)

    Sadowski, Samira M; Neychev, Vladimir; Millo, Corina; Shih, Joanna; Nilubol, Naris; Herscovitch, Peter; Pacak, Karel; Marx, Stephen J; Kebebew, Electron

    2016-02-20

    Gastro-entero-pancreatic neuroendocrine tumors (GEPNETs) are increasing in incidence, and accurate staging is important for selecting the appropriate treatment. (68)Ga-DOTATATE imaging is a promising approach for detecting GEPNETs and could help in selecting optimal therapeutic strategies. The aim of this study was to prospectively determine the clinical utility of (68)Ga-DOTATATE positron emission tomography (PET)/computed tomography (CT) in detecting unknown primary and metastatic GEPNETs. One hundred thirty-one patients were enrolled in a prospective study of patients undergoing (68)Ga-DOTATATE PET/CT, (111)In-pentetreotide single-photon emission computed tomography (SPECT)/CT and multiphasic CT scan, and/or magnetic resonance imaging in a blinded fashion with comprehensive biochemical testing. The primary outcome measure was the detection of lesions by each imaging study. (68)Ga-DOTATATE PET/CT imaging detected 95.1% of lesions (95% CI, 92.4% to 96.8%) with an average maximum standardized uptake value of 65.4 ± 47 (range, 6.9 to 244), anatomic imaging detected 45.3% of lesions (95% CI, 37.9% to 52.9%), and (111)In-pentetreotide SPECT/CT detected 30.9% of lesions (95% CI, 25.0% to 37.5%), with a significant difference between imaging modalities (P < .001). In four of 14 patients (28.6%), (68)Ga-DOTATATE PET/CT found a previously unknown primary tumor, and detected primary GEPNET, lymph node, and distant metastases correctly in 72 of 113 lesions (63.7%) when compared with histopathology, with 22.1% and 38.9% detected by using (111)In-pentetreotide SPECT/CT and anatomic imaging, respectively. On the basis of findings with (68)Ga-DOTATATE PET/CT, 43 of 131 patients (32.8%) had a change in management recommendation. In patients with carcinoid symptoms but negative biochemical testing, (68)Ga-DOTATATE PET/CT detected lesions in 65.2% of patients, 40% of which were detected neither by anatomic imaging nor by (111)In-pentetreotide SPECT/CT. (68)Ga-DOTATATE PET

  1. Frequencies and implications of discordant findings of interictal SPECT and itcal SPECT in patients with intractable epilepsy

    International Nuclear Information System (INIS)

    Lee, D. S.; Lee, S. K.; Jeong, J. K.; Lee, M. C.; Ko, C. S.

    1997-01-01

    Interictal SPECT could be used at best as a reference image to ictal SPECT, and cause sometimes confusion if it had given unexplained discordant findings from ictal SPECT. We investigated implications of discordant findings which occurred in 26 among 268 which found their epileptogenic zones using ictal EEG and/or operative outcome. Sensitivity of interictal SPECT was only 36%. Among these 268, 69 patients had no structural lesions on MR, 14 of whom had decreased perfusion on interictal SPECT (8 trues and 6 falses (adjacent or contralateral)). Structural lesion were found in 199 on MR, 103 of whom had decreased perfusion (89 trues and 14 falses). Among 26 having discordant cases, 10 interictal SPECT were proved wrong after operation and/or invasive EEG and the other 16 were on speculation using PET and ictal EEG. Ictal hyperperfusion was observed in 14 patients in these interictal SPECT. Six ictal studies were found postictal accompanied by contralateral propagation or not. Two patients had dual pathology, and the remaining 2 unknown. Interictal SPECT was done on the 2nd day after ictal study(24), the 3rd day (18), the 4th day(16), the 5th day (23). Four among 24 interictal studies (17%) of the 2nd day and the other 4 among 57 of 3rd to 5th day revealed ictal hyperperfusion on interictal SPECT. Six interictal studies (2.7% among 221) acquired on the indifferent day showed also ictal hyperperfusion. We could suggest that the next day is not desirable for interictal SPECT after ictal study, as ictal hyperperfusion on interictal study confounded more than postictal findings of ictal SPECT in the discrete localization than reassuring ictal study

  2. Frequencies and implications of discordant findings of interictal SPECT and itcal SPECT in patients with intractable epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D S; Lee, S K; Jeong, J K; Lee, M C; Ko, C S [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    1997-07-01

    Interictal SPECT could be used at best as a reference image to ictal SPECT, and cause sometimes confusion if it had given unexplained discordant findings from ictal SPECT. We investigated implications of discordant findings which occurred in 26 among 268 which found their epileptogenic zones using ictal EEG and/or operative outcome. Sensitivity of interictal SPECT was only 36%. Among these 268, 69 patients had no structural lesions on MR, 14 of whom had decreased perfusion on interictal SPECT (8 trues and 6 falses (adjacent or contralateral)). Structural lesion were found in 199 on MR, 103 of whom had decreased perfusion (89 trues and 14 falses). Among 26 having discordant cases, 10 interictal SPECT were proved wrong after operation and/or invasive EEG and the other 16 were on speculation using PET and ictal EEG. Ictal hyperperfusion was observed in 14 patients in these interictal SPECT. Six ictal studies were found postictal accompanied by contralateral propagation or not. Two patients had dual pathology, and the remaining 2 unknown. Interictal SPECT was done on the 2nd day after ictal study(24), the 3rd day (18), the 4th day(16), the 5th day (23). Four among 24 interictal studies (17%) of the 2nd day and the other 4 among 57 of 3rd to 5th day revealed ictal hyperperfusion on interictal SPECT. Six interictal studies (2.7% among 221) acquired on the indifferent day showed also ictal hyperperfusion. We could suggest that the next day is not desirable for interictal SPECT after ictal study, as ictal hyperperfusion on interictal study confounded more than postictal findings of ictal SPECT in the discrete localization than reassuring ictal study.

  3. Detection of mediastinitis after heart transplantation by gallium-67 scintigraphy

    International Nuclear Information System (INIS)

    Quirce, R.; Serano, J.; Arnal, C.; Banzo, I.; Carril, J.M.

    1991-01-01

    We report the findings of a patient with post-cardiac transplant mediastinitis detected by 67 Ga-citrate imaging. Fever and leukocytosis were the first clinical signs suggesting infection. The usual diagnostic modalities, including CT and ultrasound, failed to identify the site of infection. A 67 Ga scan showed intense abnormal uptake behind the sternum. The site of uptake was shown by necropsy to be necrotic tissue involving cardiac sutures, pulmonary arteries, and the aorta due to infection with Haemophilus aphrophilus

  4. Impurity 'hot' atoms 67Ga in a role a physical-chemical studies at an estimation of radiation damage in Zn cyclotron targets after bombardment with charged particles

    International Nuclear Information System (INIS)

    Alekseev, I.E.; Lazarev, V.V.

    2006-01-01

    In this paper, the migration of impurity 'hot atoms' 67 Ga produced from various types of nuclear reaction on zinc targets is reported. The type of charged particles as well as their energy, beam current, total fluency was varied

  5. Vertebral uptake of Tc-99m macroaggregated albumin (MAA) with SPECT/CT occurring in superior vena cava obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Karls, Shawn; Hassoun, Hani; Derbekyan, Vilma [Dept. of Nuclear Madicine, Royal Victoria Hospital, Montreal (Canada)

    2016-09-15

    A 67-year-old male presented with dyspnea for which lung scintigraphy was ordered to rule out pulmonary embolus. Planar images demonstrated abnormal midline uptake of Tc-99m macroaggregated albumin, which SPECT/CT localized to several thoracic vertebrae. Thoracic vertebral uptake on perfusion lung scintigraphy was previously described on planar imaging. Radionuclide venography and contrast-enhanced CT subsequently demonstrated superior vena cava (SVC) obstruction with collateralization through the azygous/hemiazygous system and vertebral venous plexus. SPECT/CT differentiated residual esophageal/tracheal ventilation activity, a clinically insignificant finding, from vertebral uptake indicative of SVC obstruction, a potentially life-threatening condition.

  6. Performance of Myocardial Perfusion Imaging Using Multi-focus Fan Beam Collimator with Resolution Recovery Reconstruction in a Comparison with Conventional SPECT

    International Nuclear Information System (INIS)

    Matsutomo, Norikazu; Nagaki, Akio; Sasaki, Masayuki

    2014-01-01

    IQ-SPECT is an advanced high-speed SPECT modality for myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQ-SPECT with conventional SPECT in terms of performance, based on standard clinical protocols. In addition, we examined the concordance between conventional and IQ-SPECT in patients with coronary artery disease (CAD). Fifty-three patients, undergoing rest-gated MPI for the evaluation of known or suspected CAD, were enrolled in this study. In each patient, conventional SPECT ( 99m Tc-tetrofosmin, 9.6 min and 201 Tl, 12.9 min) was performed, immediately followed by IQ-SPECT, using a short acquisition time (4.3 min for 99m Tc-tetrofosmin and 6.2 min for 201 Tl). A quantitative analysis was performed on an MPI polar map, using a 20-segment model of the left ventricle. An automated analysis by gated SPECT was carried out to determine the left ventricular volume and function including end-diastolic volume (EDV), end-systolic volume (ESV), and left ventricular ejection fraction (LVEF). The degree of concordance between conventional SPECT and IQ-SPECT images was evaluated according to linear regression and Bland-Altman analyses. The segmental percent uptake exhibited a significant correlation between IQ-SPECT and conventional SPECT (P<0.05). The mean differences in 99m Tc-tetrofosmin studies were 1.1±6.6% (apex), 2.8±5.7% (anterior wall), 2.9±6.2% (septal wall), 4.9±6.7% (lateral wall), and 1.8±5.6% (inferior wall). Meanwhile, regarding the 201 Tl-SPECT studies, these values were 1.6±6.9%, 2.0±6.6%, 2.1±5.9%, 3.3±7.2%, and 2.4±5.8%, respectively. Although the mean LVEF in IQ-SPECT tended to be higher than that observed in conventional SPECT (conventional SPECT=64.8±11.8% and IQ-SPECT=68.3±12.1% for 99m Tc-tetrofosmin; conventional SPECT= 56.0±11.7% and IQ-SPECT=61.5±12.2% for 201 Tl), quantitative parameters were not significantly different between

  7. SPECT Myocardial Blood Flow Quantitation Concludes Equivocal Myocardial Perfusion SPECT Studies to Increase Diagnostic Benefits.

    Science.gov (United States)

    Chen, Lung-Ching; Lin, Chih-Yuan; Chen, Ing-Jou; Ku, Chi-Tai; Chen, Yen-Kung; Hsu, Bailing

    2016-01-01

    Recently, myocardial blood flow quantitation with dynamic SPECT/CT has been reported to enhance the detection of coronary artery disease in human. This advance has created important clinical applications to coronary artery disease diagnosis and management for areas where myocardial perfusion PET tracers are not available. We present 2 clinical cases that undergone a combined test of 1-day rest/dipyridamole-stress dynamic SPECT and ECG-gated myocardial perfusion SPECT scans using an integrated imaging protocol and demonstrate that flow parameters are capable to conclude equivocal myocardial perfusion SPECT studies, therefore increasing diagnostic benefits to add value in making clinical decisions.

  8. Comparison of activity measurements of the 67Ga and 123I at Brazilian nuclear medicine services

    International Nuclear Information System (INIS)

    Santos, J.A. dos; Silva, M.A.L. da; Lopes, R.T.; Iwahara, A.; Oliveira, A.E. de; Tauhata, L.

    2003-01-01

    Since 1998, the National Laboratory for Ionizing Radiations (LNMRI), of Institute for Radioprotection and Dosimetry, belonging to the Brazilian Commission for Nuclear Energy (IRD/CNEN), is conducting a comparison program for the measurements of radiopharmaceutical activities applied to to patients at the nuclear medicine sector, viewing to assessment the quality of that measurements. This work presents the results of three comparison rounds using the 67 Ga and 123 I, establishing the metrological tracking of the calibrators used by the participants. The results were analysed under the the viewpoint of the conformal with the regulatory authority and show that those comparisons are necessary to improve the quality of radiopharmaceutical measurement activities, identify failures on the equipment and technical procedures used by the nuclear medicine services all over the country

  9. Comparison of activity measurements of the {sup 67}Ga and {sup 123}I at Brazilian nuclear medicine services; Comparacao das medicoes de atividade do {sup 67}Ga e {sup 123}I em servicos de medicina nuclear brasileiros

    Energy Technology Data Exchange (ETDEWEB)

    Santos, J.A. dos; Silva, M.A.L. da; Lopes, R.T. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE)], e-mail: joyra@ird.gov.br, e-mail: leobino@ird.gov.br, e-mail: ricardo@lin.ufrj.br; Iwahara, A.; Oliveira, A.E. de; Tauhata, L. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. Nacional de Metrologia das Radiacoes Ionizantes (LNMRI)], e-mail: iwahara@ird.gov.br, e-mail: aedu@ird.gov.br, e-mail: tauhata@ird.gov.br

    2003-07-01

    Since 1998, the National Laboratory for Ionizing Radiations (LNMRI), of Institute for Radioprotection and Dosimetry, belonging to the Brazilian Commission for Nuclear Energy (IRD/CNEN), is conducting a comparison program for the measurements of radiopharmaceutical activities applied to to patients at the nuclear medicine sector, viewing to assessment the quality of that measurements. This work presents the results of three comparison rounds using the {sup 67}Ga and {sup 123}I, establishing the metrological tracking of the calibrators used by the participants. The results were analysed under the the viewpoint of the conformal with the regulatory authority and show that those comparisons are necessary to improve the quality of radiopharmaceutical measurement activities, identify failures on the equipment and technical procedures used by the nuclear medicine services all over the country.

  10. HMPAO-SPECT in cerebral seizures

    International Nuclear Information System (INIS)

    Gruenwald, F.; Bockisch, A.; Reichmann, K.; Ammari, B.; Hotze, A.; Biersack, H.J.; Durwen, H.; Buelau, P.; Elger, C.E.; Rohde, A.; Penin, H.

    1988-01-01

    In nine patients with suspected psychogenic seizures and in three patients with proven epileptic seizures HMPAO-SPECT was performed prior to and during seizure. In the patients with lateron-proven psychogenic seizures no, or only slight, changes of regional cerebral blood flow were found. Patients with proven epilepsy revealed partly normal findings interictally but during seizure a markedly increased circumscript blood flow was found in all patients. Even though PET is superior to SPECT with respect to spatial resolution, in the diagnosis of seizures HMPAO-SPECT has the advantage of enabling injection of the tracer during the seizure and the performance of the SPECT study subsequently. (orig.) [de

  11. In vivo and in vitro evaluation of dota-lanreotide radiolabelled with gallium-67

    International Nuclear Information System (INIS)

    Aldegheri, Eliane Bernardes

    2005-01-01

    One of the refinements of modern Nuclear Medicine is the capacity of providing dynamic and kinetics images of the administered radiopharmaceutical, reproducing its transport mechanism, action sites, receptor binding and excretion route. With the continues technological advances new radiopharmaceuticals have been developed in order to express higher specificity and with higher characters of affinity between receptor/complex. One radiopharmaceutical is formed by a reagent or bio molecule that has in its structure a radioisotope, that has the objectives of carrying it to the organs of affinity or to benign or malign tumoral process. Somatostatin inhibits the growing and proliferation of several tumoral cells. Somatostatin analogs bind to somatostatic receptors that are expressed in different kind of neoplasia DOTA-LANREOTIDE (DOTALAN) is an octapeptide analog to somatostatin. The interest of labeling the bio conjugate with gallium-67 in Nuclear Medicine comes from its physical, chemical and biological properties. Besides its gamma radiation, useful in the diagnosis of inflammation and infection foci, 67 Ga emits Auger electrons (0.1 - 8 keV) and conversion electrons (80 - 90 keV), making it attractive to internal radiotherapy if the vectors used to lead the radionuclide to the tumoral cell are internalized. The objective of this work was to develop a methodology of labelling DOTA-LANREOTIDE with 67 Ga, optimizing the labelling variables and its quality control. The novelty aspect was the comparison between labeling with national and imported 67 Ga, in its original and purified forms. The purification of 67 Ga was essential to reach yields higher than 90%. The radiolabelled bio conjugate peptides must be free of metallic contaminants that could compete in the labeling process. The following procedure was established after studying the labeling parameters: mass of peptide of 10 μg (6nmol), pH5, final reaction volume of 170 μL of the labelled and 67 Ga activity of 222

  12. Early detection of drug-induced pneumonitis by gallium-67 lung scan in six patients with normal chest radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, H; Sawa, H; Takashima, S [Osaka City Univ. (Japan). Hospital

    1981-06-01

    Increased pulmonary accumulation of Gallium-67-citrate was observed in 6 patients (4 with malignant lymphoma, 1 with uterine cancer and 1 with acute myelocytic leukemia) preceding the appearance of any abnormal findings in both chest X-ray and blood gas data. All of them had received multiple courses of chemotherapy. In these patients, the anticancer drugs were administered for 13 to 22 weeks (mean 15 weeks). One patient with malignant lymphoma showed abnormal /sup 67/Ga lung uptake greater than hepatic activity, 3 patients (malignant lymphoma, 2 and uterine cancer, 1) visualized abnormal /sup 67/Ga lung uptake equal to hepatic activity and 2 cases (malignant lymphoma, 1 and acute myelocytic leukemia, 1) demonstrated abnormal accumulation of /sup 67/Ga in the lung greater than background activity. In 4 patients (3 with malignant lymphoma and 1 with uterine cancer) out of 6, transbronchial lung biopsy obtained after the /sup 67/Ga scans showed non-specific interstitial pneumonitis with infiltration of lymphocytes and macrophages compatible with drug-induced pneumonitis. In the other 2 patients, cytology and cultures were negative and follow up /sup 67/Ga lung scans revealed a reduction in intensity of uptake after treatment with corticosteroid. Therefore, we considered that the /sup 67/Ga lung scan was useful for early detection of drug-induced pneumonitis.

  13. Can perfusion SPECT aid CTPA interpretation?

    International Nuclear Information System (INIS)

    Gradinscak, D. J.; Roach, P.; Bailey, E.; Kueh, S.

    2009-01-01

    Full text:Objective: To determine whether fusion of perfusion SPECT and CTPA improves the diagnostic accuracy of CTPA. Methods: 35 patients with suspected PE who underwent both CTPA and SPECT V/Q within 48 hours were included. Of these, the majority (n=30) had PE as determined by the V/Q SPECT scan and the others (n=5) were negative for PE. The clinical reports of CTPA were reviewed and pulmonary emboli tabulated based on anatomical location. A second radiologist, blinded to the results of the clinical read and the V/Q SPECT scan, reviewed the CTPA with and without perfusion SPECT fusion for assistance. Results: A total 57 PE were reported on the clinical reports and 60 PE identified on the blinded read. Fused CTPA/perfursion SPECT images identified a further 5 PE not identified on the clinical read (8% increase) and 2 PE not identified on the blinded read (3% increase). The additional emboli detected resulted in a change in final diagnosis from PE negative to PE positive in 2 patients (6%) compared with the clinical read and 1 patient (3%) compared with the blinded read without SPECT fusion. Conclusion: Fused CTPA-SPECT perfusion improves the sensitivity of CTPA for the detection of PE in a small number of patients. Fused data may help guide the radiologist to identify sites of PE on CTPA.

  14. Detection of pulmonary embolism with combined ventilation-perfusion SPECT and low-dose CT: head-to-head comparison with multidetector CT angiography

    DEFF Research Database (Denmark)

    Gutte, Henrik; Mortensen, Jann; Jensen, Claus Verner

    2009-01-01

    The diagnosis of pulmonary embolism (PE) is usually established by a combination of clinical assessment, D-dimer testing, and imaging with either pulmonary ventilation-perfusion (V/Q) scintigraphy or pulmonary multidetector CT (MDCT) angiography. Both V/Q SPECT and MDCT angiography seem to have...... high diagnostic accuracy. However, only limited data directly comparing these 2 modalities are available. Hybrid gamma-camera/MDCT systems have been introduced and allow simultaneous 3-dimensional lung V/Q SPECT and MDCT angiography, suitable for diagnosing PE. The aim of our study was to compare...

  15. Diagnostic role of (99)Tc(m)-MDP SPECT/CT combined SPECT/MRI Multi modality imaging for early and atypical bone metastases.

    Science.gov (United States)

    Chen, Xiao-Liang; Li, Qian; Cao, Lin; Jiang, Shi-Xi

    2014-01-01

    The bone metastasis appeared early before the bone imaging for most of the above patients. (99)Tc(m)-MDP ((99)Tc(m) marked methylene diphosphonate) bone imaging could diagnosis the bone metastasis with highly sensitivity, but with lower specificity. The aim of this study is to explore the diagnostic value of (99)Tc(m)-MDP SPECT/CT combined SPECT/MRI Multi modality imaging for the early period atypical bone metastases. 15 to 30 mCi (99)Tc(m)-MDP was intravenously injected to the 34 malignant patients diagnosed as doubtful early bone metastases. SPECT, CT and SPECT/CT images were captured and analyzed consequently. For the patients diagnosed as early period atypical bone metastases by SPECT/CT, combining the SPECT/CT and MRI together as the SPECT/MRI integrated image. The obtained SPECT/MRI image was analyzed and compared with the pathogenic results of patients. The results indicated that 34 early period doubtful metastatic focus, including 34 SPECT positive focus, 17 focus without special changes by using CT method, 11 bone metastases focus by using SPECT/CT method, 23 doubtful bone metastases focus, 8 doubtful bone metastases focus, 14 doubtful bone metastases focus and 2 focus without clear image. Totally, SPECT/CT combined with SPECT/MRI method diagnosed 30 bone metastatic focus and 4 doubtfully metastatic focus. In conclusion, (99)Tc(m)-MDP SPECT/CT combined SPECT/MRI Multi modality imaging shows a higher diagnostic value for the early period bone metastases, which also enhances the diagnostic accuracy rate.

  16. 99mTc-HMPAO Brain SPECT in Seizure Disorder: Comparison Brain SPECT, MRI / CT and EEG

    International Nuclear Information System (INIS)

    Yang, Hyung In; Im, Ju Hyuk; Choi, Chang Woon; Lee, Dong Soo; Chung, June Key; No, Jae Kyu; Lee, Myung Chul; Koh, Chang Soon

    1994-01-01

    We studied 115 patients with seizure who had been performed brain SPECT brain MRI of CT and EEG. To evaluate the pattern of brain SPECT in seizure patients 28 of them had secondary epilepsies, 87 had primary epilepsies. In primary epilepsies, 42 were generalized seizure and 45 were partial seizure. The causes of secondary epilepsies were congenital malformation, cerebromalacia, cerebral infarction ultiple sclerosis, AV-malformation. granuloma and etc, in order. In 28 secondary epilepsies, 25 of them, brain SPECT lesions was concordant with MRI or CT lesions. 3 were disconcordant. The brain SPECT findings of generalized seizure were normal in 22 patients, diffuse irregular decreased perfusion in 8, decreased in frontal cortex in 4. temporal in 5 and frontotemporal in 3. In 45 partial seizure, 19 brain SPECT were concordant with EEG (42.4%).

  17. Sequential SPECT/CT imaging starting with stress SPECT in patients with left bundle branch block suspected for coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Engbers, Elsemiek M.; Mouden, Mohamed [Isala, Department of Cardiology, Zwolle (Netherlands); Isala, Department of Nuclear Medicine, Zwolle (Netherlands); Timmer, Jorik R.; Ottervanger, Jan Paul [Isala, Department of Cardiology, Zwolle (Netherlands); Knollema, Siert; Jager, Pieter L. [Isala, Department of Nuclear Medicine, Zwolle (Netherlands)

    2017-01-15

    To investigate the impact of left bundle branch block (LBBB) on sequential single photon emission computed tomography (SPECT)/ CT imaging starting with stress-first SPECT. Consecutive symptomatic low- to intermediate-risk patients without a history of coronary artery disease (CAD) referred for SPECT/CT were included from an observational registry. If stress SPECT was abnormal, additional rest SPECT and, if feasible, coronary CT angiography (CCTA) were acquired. Of the 5,018 patients, 218 (4.3 %) demonstrated LBBB. Patients with LBBB were slightly older than patients without LBBB (65±12 vs. 61±11 years, p<0.001). Stress SPECT was more frequently abnormal in patients with LBBB (82 % vs. 46 %, p<0.001). After reviewing stress and rest images, SPECT was normal in 43 % of the patients with LBBB, compared to 77 % of the patients without LBBB (p<0.001). Sixty-four of the 124 patients with LBBB and abnormal stress-rest SPECT underwent CCTA (52 %), which could exclude obstructive CAD in 46 of the patients (72 %). Sequential SPECT/CT imaging starting with stress SPECT is not the optimal imaging protocol in patients with LBBB, as the majority of these patients have potentially false-positive stress SPECT. First-line testing using CCTA may be more appropriate in low- to intermediate-risk patients with LBBB. (orig.)

  18. Methods of gated-blood-pool-spect data processing

    International Nuclear Information System (INIS)

    Kosa, I.; Mester, J.; Tanaka, M.; Csernay, L.; Mate, E.; Szasz, K.

    1991-01-01

    Three techniques of gated SPECT were evaluated. The methods of Integral SPECT (ISPECT), enddyastole-endsystole SPECT (ED-ES SPECT) and Fourier SPECT were adapted and developed on the Hungarian nuclear medicine data processing system microSEGAMS. The methods are based on data reduction before back projection which results in processing times acceptable for the clinical routine. The clinical performance of the introduced techniques was tested in 10 patients with old posterior myocardial infarction and in 5 patients without cardiac disease. The left ventricular ejection faction determined by ISPECT correlated well with the planar values. The correlation coefficient was 0.89. The correlation coefficient of EF values determined by ED-ES SPECT and planar radionuclide ventriculography was lower (0.70). For the identification of left ventricular wall motion abnormalities ED-ES SPECT and Fourier SPECT exhibited a favourable performance, but ISPECT only moderate suitability. In the detection of regional phase delay Fourier-SPECT demonstrated higher sensitivity than the planar radionuclide ventriculography. (author) 4 refs.; 3 figs.; 2 tabs

  19. A hybrid GA-TS algorithm for open vehicle routing optimization of coal mines material

    Energy Technology Data Exchange (ETDEWEB)

    Yu, S.W.; Ding, C.; Zhu, K.J. [China University of Geoscience, Wuhan (China)

    2011-08-15

    In the open vehicle routing problem (OVRP), the objective is to minimize the number of vehicles and the total distance (or time) traveled. This study primarily focuses on solving an open vehicle routing problem (OVRP) by applying a novel hybrid genetic algorithm and the Tabu search (GA-TS), which combines the GA's parallel computing and global optimization with TS's Tabu search skill and fast local search. Firstly, the proposed algorithm uses natural number coding according to the customer demands and the captivity of the vehicle for globe optimization. Secondly, individuals of population do TS local search with a certain degree of probability, namely, do the local routing optimization of all customer sites belong to one vehicle. The mechanism not only improves the ability of global optimization, but also ensures the speed of operation. The algorithm was used in Zhengzhou Coal Mine and Power Supply Co., Ltd.'s transport vehicle routing optimization.

  20. SPECT data acquisition and image reconstruction in a stationary small animal SPECT/MRI system

    Science.gov (United States)

    Xu, Jingyan; Chen, Si; Yu, Jianhua; Meier, Dirk; Wagenaar, Douglas J.; Patt, Bradley E.; Tsui, Benjamin M. W.

    2010-04-01

    The goal of the study was to investigate data acquisition strategies and image reconstruction methods for a stationary SPECT insert that can operate inside an MRI scanner with a 12 cm bore diameter for simultaneous SPECT/MRI imaging of small animals. The SPECT insert consists of 3 octagonal rings of 8 MR-compatible CZT detectors per ring surrounding a multi-pinhole (MPH) collimator sleeve. Each pinhole is constructed to project the field-of-view (FOV) to one CZT detector. All 24 pinholes are focused to a cylindrical FOV of 25 mm in diameter and 34 mm in length. The data acquisition strategies we evaluated were optional collimator rotations to improve tomographic sampling; and the image reconstruction methods were iterative ML-EM with and without compensation for the geometric response function (GRF) of the MPH collimator. For this purpose, we developed an analytic simulator that calculates the system matrix with the GRF models of the MPH collimator. The simulator was used to generate projection data of a digital rod phantom with pinhole aperture sizes of 1 mm and 2 mm and with different collimator rotation patterns. Iterative ML-EM reconstruction with and without GRF compensation were used to reconstruct the projection data from the central ring of 8 detectors only, and from all 24 detectors. Our results indicated that without GRF compensation and at the default design of 24 projection views, the reconstructed images had significant artifacts. Accurate GRF compensation substantially improved the reconstructed image resolution and reduced image artifacts. With accurate GRF compensation, useful reconstructed images can be obtained using 24 projection views only. This last finding potentially enables dynamic SPECT (and/or MRI) studies in small animals, one of many possible application areas of the SPECT/MRI system. Further research efforts are warranted including experimentally measuring the system matrix for improved geometrical accuracy, incorporating the co

  1. 99mTc-HMPAO labeled leucocyte, 99mTc-labeled antigranulocyte antibody and 67Ga scintigraphy in the evaluation of painful hip and knee prosthetic replacements

    International Nuclear Information System (INIS)

    Oliveira, S.; Pereira, L.; Joao, F.; Lima, J.

    2003-01-01

    Full text: Objective: To evaluate the utility of 99mTc-HMPAO labeled leucocyte, 99mTc-labeled anti-granulocyte antibody and 67Ga scintigraphy in patients suspected to have infected hip and knee replacements, from March/1998 to March/ 2002. Methods: Retrospective study of 33 patients (12 male, 21 female) with an average age of 61,1 ± 7,3 years. Nineteen had hip replacements and 14 were submitted to knee replacements. 99mTc-HMPAO labeled leucocyte scintigraphy was performed in 17 patients, 99mTc-labeled anti-granulocyte antibody scintigraphy in 13 patients and 67Ga scintigraphy in 3 patients. Twenty-six patients were also submitted to 3-phase 99mTc-MDP bone scintigraphy. Results were compared to those from studies with infection/inflammation agents. Concordant positive studies were considered to be a positive result for infection. A second study using 67Ga was also performed in 3 patients. Results: Diagnosis was based on surgical findings in 14 patients, pathologic study of biopsy specimen in 1 case and clinical/ imaging follow-up in 18 patients. Infection was detected in 22 cases and absent in 11. The conjoined evaluation of scintigraphic studies considered infection to be present in 20 cases and absent in 13. With infection/inflammation agents, 20 cases were positive (+) and 13 cases were negative (-). Using 99mTc-HMPAO labeled leucocytes, 12 cases were (+) and 5 cases were (-). With 99mTc-labeled anti-granulocyte antibodies, 8 cases were (+) and 5 were (-). With 67Ga, all 3 cases were (-). In patients with (+) studies using infection/ inflammation agents, a false positive case with 99mTc-HMPAO labeled leucocytes was reported. Two false negative cases were detected, both with 99mTc-labeled antigranulocyte antibodies, in patients with (-) studies. Regarding the studies with 99mTc-MDP, 24 were (+) and 2 were (-). Eighteen of these (+) cases were also (+) in studies with infection/inflammation agents, but 6 were (-) with these agents. Negative cases were also (-) in

  2. SPECT in psychiatry

    International Nuclear Information System (INIS)

    Kasper, S.; Gruenwald, F.; Walter, H.; Klemm, E.; Podreka, I.; Biersack, H.J.

    1994-01-01

    In the last fifteen years different attempts have been undertaken to understand the biological basis of major psychiatric disorders. One important tool to determine patterns of brain dysfunction is single emission computed tomography (SPECT). Whereas SPECT investigations are already a valuable diagnostic instrument for the diagnosis of dementia of the Alzheimer Type (DAT) there have not been consistent findings that can be referred to as specific for any other particular psychiatric diagnostic entity. Nevertheless, SPECT studies have been able to demonstrate evidence of brain dysfunction in patients with schizophrenia, depression, anxiety disorders, and substance abuse in which other methods showed no clear abnormality of brain function. Our manuscript reviews the data which are currently available in the literature and stresses the need for further studies, especially for prediction and monitoring psychiatric treatment modalities. (orig.) [de

  3. Gallium-67 accumulation in the stomach

    Energy Technology Data Exchange (ETDEWEB)

    Tomita, Masayoshi; Irie, Goro; Itoh, Kazuo; Furudate, Masayori

    1988-10-01

    Scintigraphy with Ga-67 citrate routinely performed which showed an uptake in the stomach was reviewed retrospectively. There were 24 cases correlated ; 7 cases with malignant lymphoma in the stomach, 4 with gastric carcinoma, 2 with gastritis, 1 with abscess after gastroenterostomy and 8 with no disease detected. The Ga-uptake in the stomach in those was patterned to 4 groups. Rod and wall patterns were unlikely in malignant diseases of the stomach. On the other hand, focal or irregular uptake was commonly seen in malignant diseases of the stomach. Those Ga-uptake patterns may be useful to interprete complicated distribution of the radiogallium in the G.I. tracts of the left upper abdomen.

  4. Incremental value of 99mTc-HYNIC-TOC SPECT/CT over whole-body planar scintigraphy and SPECT in patients with neuroendocrine tumours.

    Science.gov (United States)

    Trogrlic, Mate; Težak, Stanko

    2017-06-12

    The aim of this study was to evaluate the additional value of 99m Tc-HYNIC-TOC SPECT/CT over planar whole-body (WB) scintigraphy and SPECT alone in the detection and accurate localisation of neuroendocrine tumour (NET) lesions. This study included 65 patients with a definitive histological diagnosis of NET prior to scintigraphy. Planar WB scintigraphy, SPECT, and SPECT/CT images were acquired at 4 h post-administration of 670 MBq 99m Tc-HYNIC-TOC. Additional SPECT images at 10 min after tracer administration were also acquired. Clinical and imaging follow-up findings were considered as the reference standards (minimum follow-up period, 15 months). Patient and lesion-based analyses of the efficacies of the imaging modalities were performed. While 38 patients exhibited metastasis of NETs, 27 presented no evidence of metastasis. Upon patient-based analysis, the sensitivity and specificity of SPECT/CT were found to be 88.9 and 79.3 %, respectively. The diagnostic accuracies of WB scintigraphy, 4h-SPECT, and SPECT/CT were 72.3, 73.8, and 84.6 %, respectively. The area under curve (AUC) value for SPECT/CT (0.84) was the highest, followed by those for 4h-SPECT (0.75) and WB scintigraphy (0.74). The accuracy and AUC values of SPECT/CT were significantly better compared to those of WB scintigraphy (p < 0.001), 10 min-SPECT (p < 0.001), and 4 h-SPECT (p = 0.001). The findings of SPECT/CT led to the change in treatment plan of 11 patients (16.9 %). The sensitivity and diagnostic accuracy of SPECT/CT in the evaluation of NET lesions outperforms planar WB imaging or SPECT alone.

  5. Comparison of technetium-99m methoxyisobutylisonitrile and gallium-67 citrate scanning in the assessment of lymphomas

    International Nuclear Information System (INIS)

    Ziegels, P.; Nocaudie, M.; Huglo, D.; Deveaux, M.; Detourmignies, L.; Wattel, E.; Marchandise, X.

    1995-01-01

    The aim of this study was to compare the value of scintigraphy using technetium-99m methoxy-isobutylisonitrile (MIBI) with that of scintigraphy using gallium-67 citrate in the assessment of Hodgkin's disease and non-Hodgkin's lymphoma and to relate these results with those of CT scan and MRI. Fifty-eight patients were included either for a follow-up examination or for monitoring of their treatment. Twenty-three residual masses were studied. A whole-body scan was performed, followed by single-photon emission computed tomography (SPET) 20 min after injection of 740 MBq of 99m Tc-MIBI and 72 h after injection of 185 MBq of 67 Ga citrate. The overall sensitivity of 99m Tc-MIBI and 67 Ga citrate was 71% and 68%, respectively, and the overall specificity was 76% and 44%, respectively. For residual masses, the sensitivity was 44% with both tracers and the specificity was 80% with 99m Tc-MIBI and 53% with 67 Ga citrate. The positive predictive values were 85% and 68% and the negative predictive values were 59% and 44%, respectively. The signal-to-background ratio was 1.5 for 99m Tc-MIBI and 2 for 67 Ga citrate. At present, 99m Tc-MIBI cannot replace 67 Ga citrate in the assessment of lymphomas. (orig.)

  6. Normal anatomy of lung perfusion SPECT scintigraphy

    International Nuclear Information System (INIS)

    Moskowitz, G.W.; Levy, L.M.

    1987-01-01

    Ten patients studies for possible pulmonary embolic disease had normal lung perfusion planar and SPECT scintigraphy. A computer program was developed to superimpose the CT scans on corresponding SPECT images. Superimposition of CT scans on corresponding SPECT transaxial cross-sectional images, when available, provides the needed definition and relationships of adjacent organs. SPECT transaxial sections provide clear anatomic definition of perfusion defects without foreground and background lung tissue superimposed. The location, shape, and size of the perfusion defects can be readily assessed by SPECT. An algorithm was developed for the differentiation of abnormal pulmonary perfusion patterns from normal structures on variation

  7. In-situ optical emission spectroscopy for a better control of hybrid sputtering/evaporation process for the deposition of Cu(In,Ga)Se{sub 2} layers

    Energy Technology Data Exchange (ETDEWEB)

    Posada, Jorge; Jubault, Marie [Institute of Research and Development on Photovoltaic Energy (IRDEP), EDF-CNRS-Chimie ParisTech, UMR 7174, 6 Quai Watier, 78401 Chatou (France); Bousquet, Angélique; Tomasella, Eric [Clermont Université, Université Blaise Pascal, Institute of Chemistry of Clermont-Ferrand (ICCF), CNRS-UMR 6296, 24 Avenue des Landais, 63171 Aubière (France); Lincot, Daniel [Institute of Research and Development on Photovoltaic Energy (IRDEP), EDF-CNRS-Chimie ParisTech, UMR 7174, 6 Quai Watier, 78401 Chatou (France)

    2015-05-01

    In this work, we have developed a hybrid one-step co-sputtering/evaporation Cu(In,Ga)Se{sub 2} (CIGS) process, where Cu, In and Ga are sputtered simultaneously with the thermal evaporation of selenium, thus avoiding the H{sub 2}Se use. An appropriate control of the selenium flux is very important to prevent the target poisoning and hence some material flux variations. Indeed, the control of the CIGS composition must be rigorous to ensure reproducible solar cell properties. In this regard, a study of the correlations between plasma species and thin film composition, structure and morphology has been performed by varying power values and Se evaporation temperature in the 170 to 230 °C range. We started by studying the plasma with a powerful technique: optical emission spectroscopy, following light emissions from different plasma species: sputtered Cu, Ga, In but also evaporated Se. Hence, we determined the Se flow threshold avoiding target poisoning and the main parameter controlling the CIGS composition. Obviously, we also focused our interest on the material. We measured film composition and thickness of the samples with X-ray fluorescence and by energy dispersive X-ray. Different phases formed during the process were identified by Raman spectroscopy and X-ray diffraction. The optoelectronic cell properties showed promising efficiency of 10.3% for an absorber with composition ratios of [Cu]/([In] + [Ga]) = 1.02 and [Ga]/([In] + [Ga]) = 0.44. Finally, this work shows that we are able to control this hybrid process and thus the structure and composition of CIGS thin film for industrial transfer in the photovoltaic field. - Highlights: • We have developed a hybrid one-step co-sputtering/evaporation Cu(In,Ga)Se{sub 2} process. • Correlations between plasma species and thin film composition have been performed. • We determined the Se flow threshold avoiding target poisoning. • Efficient small-area CIGS cells with 10.3% efficiency were fabricated.

  8. {sup 99m}Tc-HMPAO Brain SPECT in Seizure Disorder: Comparison Brain SPECT, MRI / CT and EEG

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Hyung In [Kyunghee University Hospital, Seoul (Korea, Republic of); Im, Ju Hyuk; Choi, Chang Woon; Lee, Dong Soo; Chung, June Key; No, Jae Kyu; Lee, Myung Chul; Koh, Chang Soon [Seoul National University Hospital, Seoul (Korea, Republic of)

    1994-03-15

    We studied 115 patients with seizure who had been performed brain SPECT brain MRI of CT and EEG. To evaluate the pattern of brain SPECT in seizure patients 28 of them had secondary epilepsies, 87 had primary epilepsies. In primary epilepsies, 42 were generalized seizure and 45 were partial seizure. The causes of secondary epilepsies were congenital malformation, cerebromalacia, cerebral infarction ultiple sclerosis, AV-malformation. granuloma and etc, in order. In 28 secondary epilepsies, 25 of them, brain SPECT lesions was concordant with MRI or CT lesions. 3 were disconcordant. The brain SPECT findings of generalized seizure were normal in 22 patients, diffuse irregular decreased perfusion in 8, decreased in frontal cortex in 4. temporal in 5 and frontotemporal in 3. In 45 partial seizure, 19 brain SPECT were concordant with EEG (42.4%).

  9. Clinical evaluation of SPECT in cerebrovascular disease

    International Nuclear Information System (INIS)

    Oshibuchi, Masao; Satoh, Mitsutaka; Kanda, Tetsuro; Nishi, Fumiaki; Yamane, Kanji; Fujimatsu, Masahiko; Edamitsu, Satoshi; Anno, Yasuro; Ohtake, Hisashi.

    1989-01-01

    In 131 patients with cerebrovascular disease, regional cerebral blood flow were determined by 123 I-IMP (N-isopropyl ( 123 I)-iodoamphetamine) or 99m Tc-HM-PAO ( 99m Tc (d, 1)-hexamethyl propyleneamine oxime) SPECT and findings were compared with those of X-CT or MRI. The perfusion deficit detected by SPECT was larger than the deficit by X-CT or MRI in every case. The perfusion deficit area was more clearly demonstrated by SPECT than by X-CT or MRI in patients with acute cerebral infarction. The hypoperfusion area determined by 123 I-IMP SPECT was wider than that by 99m Tc-HM-PAO SPECT. The crossed cerebellar diaschisis was observed in 56 out of 131 cases (43%). The results of operation were quantitatively evaluated by 123 I-IMP SPECT in 25 patients. (author)

  10. Highly selective GaN-nanowire/TiO2-nanocluster hybrid sensors for detection of benzene and related environment pollutants

    International Nuclear Information System (INIS)

    Aluri, Geetha S; Motayed, Abhishek; Davydov, Albert V; Oleshko, Vladimir P; Bertness, Kris A; Sanford, Norman A; Rao, Mulpuri V

    2011-01-01

    Nanowire-nanocluster hybrid chemical sensors were realized by functionalizing gallium nitride (GaN) nanowires (NWs) with titanium dioxide (TiO 2 ) nanoclusters for selectively sensing benzene and other related aromatic compounds. Hybrid sensor devices were developed by fabricating two-terminal devices using individual GaN NWs followed by the deposition of TiO 2 nanoclusters using RF magnetron sputtering. The sensor fabrication process employed standard microfabrication techniques. X-ray diffraction and high-resolution analytical transmission electron microscopy using energy-dispersive x-ray and electron energy-loss spectroscopies confirmed the presence of the anatase phase in TiO 2 clusters after post-deposition anneal at 700 deg. C. A change of current was observed for these hybrid sensors when exposed to the vapors of aromatic compounds (benzene, toluene, ethylbenzene, xylene and chlorobenzene mixed with air) under UV excitation, while they had no response to non-aromatic organic compounds such as methanol, ethanol, isopropanol, chloroform, acetone and 1,3-hexadiene. The sensitivity range for the noted aromatic compounds except chlorobenzene were from 1% down to 50 parts per billion (ppb) at room temperature. By combining the enhanced catalytic properties of the TiO 2 nanoclusters with the sensitive transduction capability of the nanowires, an ultra-sensitive and selective chemical sensing architecture is demonstrated. We have proposed a mechanism that could qualitatively explain the observed sensing behavior.

  11. Functional neuroimaging in epilepsy: FDG-PET and SPECT

    International Nuclear Information System (INIS)

    Lee, Sang Kun; Lee, Dong Soo

    2003-01-01

    Finding epileptogenic zone is the most important step for the successful epilepsy surgery. F-18 fluorodeoxyglucose positron emission tomography (FDG-PET) and single photon emission computed tomography (SPECT) can be used in the localization of epileptogenic foci. In medial temporal lobe epilepsy, the diagnostic sensitivity of FDG-PET and ictal SPECT is excellent. However, detection of hippocampal sclerosis by MRI is so certain that use of FDG-PET and ictal SPECT in medial temporal lobe epilepsy is limited for some occasions. In neocortical epilepsy, the sensitivities of FDG-PET or ictal SPECT are fair. However, FDG-PET and ictal SPECT can have a crucial role in the localization of epileptogenic foci for non-lesional neocortical epilepsy. Interpretation of FDG-PET has been recently advanced by voxel-based analysis and automatic volume of interest analysis based on a population template. Both analytical methods can aid the objective diagnosis of epileptogenic foci. lctal SPECT was analyzed using subtraction methods and voxel-based analysis. Rapidity of injection of tracers, ictal EEG findings during injection of tracer, and repeated ictal SPECT were important technical issues of ictal SPECT. SPECT can also be used in the evaluation of validity of Wada test

  12. Functional neuroimaging in epilepsy: FDG-PET and SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Kun; Lee, Dong Soo [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2003-02-01

    Finding epileptogenic zone is the most important step for the successful epilepsy surgery. F-18 fluorodeoxyglucose positron emission tomography (FDG-PET) and single photon emission computed tomography (SPECT) can be used in the localization of epileptogenic foci. In medial temporal lobe epilepsy, the diagnostic sensitivity of FDG-PET and ictal SPECT is excellent. However, detection of hippocampal sclerosis by MRI is so certain that use of FDG-PET and ictal SPECT in medial temporal lobe epilepsy is limited for some occasions. In neocortical epilepsy, the sensitivities of FDG-PET or ictal SPECT are fair. However, FDG-PET and ictal SPECT can have a crucial role in the localization of epileptogenic foci for non-lesional neocortical epilepsy. Interpretation of FDG-PET has been recently advanced by voxel-based analysis and automatic volume of interest analysis based on a population template. Both analytical methods can aid the objective diagnosis of epileptogenic foci. lctal SPECT was analyzed using subtraction methods and voxel-based analysis. Rapidity of injection of tracers, ictal EEG findings during injection of tracer, and repeated ictal SPECT were important technical issues of ictal SPECT. SPECT can also be used in the evaluation of validity of Wada test.

  13. Triple Detector SPECT Imaging with 99mTc-DMSA in Adult Patients with Urinary Tract Infection

    International Nuclear Information System (INIS)

    Ryu, Jin Sook; Bea, Woon Gyu; Moon, Dae Hyuk; Lee, Myung Hae; Kim, Soon Bae; Park, Su Kil; Park, Jung Sik; Hong, Chang Gi; Cho, Kyung Sik

    1992-01-01

    Although early diagnosis of urinary tract infection is important, the radiologic evaluation is still controversial because of the low sensitivity and the lack of cost-effectiveness. This study was carried out to evaluate the clinical utility of high resolution triple head 99m Tc-DMSA SPECT imaging in urinary tract infection. We prospectively performed 99m Tc-DMSA planar and SPECT imaging, ultrasound of kidney (US), intravenous pyelography (IVP) and voiding cystourethrography (VCU) in all 60 adult patients with UTI [26 with first episode of acute pyelonephritis (APN), 22 with recurrent APN, and 12 persistent asymptomatic pyuria] and 25 normal persons. To assess reversibility of the renal cortical defect (RCD), 99m Tc-DMSA SPECT was repeated 1 to 8 months later in those patients with abnormal initial findings. Overall detection rate of 99m Tc-DMSA SPECT imaging was 83% (50/60), but planar, US, IVP and VCU showed abnormal findings in 68%, 28%, 32% and 13%, respectively. 25 out of 27 patients with normal or single RCD were all normal in other radiological studies. Only two patients showed vesicoureteral reflux (VUR) on VCU (grade I) and mild hydronephrosis on IVP. But, high proportion of those with multiple RCD showed abnormal findings on US (17/33), IVP (18/33), and VCU (7/33): 67% in any of these 3 studies. Especially, 3 out 7 patients with VUR showed multiple RCD on 99m Tc-DMSA SPECT without any abnormality on IVP or US. 25 normal persons showed normal findings in all studies except one false positive finding on 99m Tc-DMSA SPECT imaging. Follow-up 99m Tc-DMSA SPECT was done in 28 patients (13 with single RCD, 15 with multiple RCD). All 13 patients with single RCD showed improvement. Those with multiple RCD presented improvement in 4, no change in 10, and aggravation in 1 on follow-up studies. With these results, we conclude: 1) 99m Tc-DMSA SPECT imaging is superior to planar imaging, US, IVP or VCU in detection of renal lesion in urinary tract infection. 99m Tc

  14. A methodology for generating normal and pathological brain perfusion SPECT images for evaluation of MRI/SPECT fusion methods: application in epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Grova, C [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Jannin, P [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Biraben, A [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Buvat, I [INSERM U494, CHU Pitie Salpetriere, Paris (France); Benali, H [INSERM U494, CHU Pitie Salpetriere, Paris (France); Bernard, A M [Service de Medecine Nucleaire, Centre Eugene Marquis, Rennes (France); Scarabin, J M [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Gibaud, B [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France)

    2003-12-21

    Quantitative evaluation of brain MRI/SPECT fusion methods for normal and in particular pathological datasets is difficult, due to the frequent lack of relevant ground truth. We propose a methodology to generate MRI and SPECT datasets dedicated to the evaluation of MRI/SPECT fusion methods and illustrate the method when dealing with ictal SPECT. The method consists in generating normal or pathological SPECT data perfectly aligned with a high-resolution 3D T1-weighted MRI using realistic Monte Carlo simulations that closely reproduce the response of a SPECT imaging system. Anatomical input data for the SPECT simulations are obtained from this 3D T1-weighted MRI, while functional input data result from an inter-individual analysis of anatomically standardized SPECT data. The method makes it possible to control the 'brain perfusion' function by proposing a theoretical model of brain perfusion from measurements performed on real SPECT images. Our method provides an absolute gold standard for assessing MRI/SPECT registration method accuracy since, by construction, the SPECT data are perfectly registered with the MRI data. The proposed methodology has been applied to create a theoretical model of normal brain perfusion and ictal brain perfusion characteristic of mesial temporal lobe epilepsy. To approach realistic and unbiased perfusion models, real SPECT data were corrected for uniform attenuation, scatter and partial volume effect. An anatomic standardization was used to account for anatomic variability between subjects. Realistic simulations of normal and ictal SPECT deduced from these perfusion models are presented. The comparison of real and simulated SPECT images showed relative differences in regional activity concentration of less than 20% in most anatomical structures, for both normal and ictal data, suggesting realistic models of perfusion distributions for evaluation purposes. Inter-hemispheric asymmetry coefficients measured on simulated data were

  15. On-line distance assisted training program for nuclear medicine technologists applied to SPECT-CT and PET-CT (Program DAT-OL). Results of a first course in Argentina

    International Nuclear Information System (INIS)

    Furnari, J C; Notari, C; Daoud, A; Giannone, C A

    2012-01-01

    The CNEA and the IDB are running for the second time the Distance Assisted Training course (DAT-OL), which is part of a global program of the International Atomic Energy Agency (IAEA) for Nuclear Medicine technologists working in centers equipped with PET CT and / or SPECT-CT hybrids. Aims: Completion of this course is justified by the strong increase in the installation of hybrid nuclear medicine (NM) systems, the increasing demand for qualified technicians and the lack of formal training opportunity. The course objective is to both promote the qualification of the technologist as improving quality and operational safety in MN participating centers. Material and Methods: This new course is free and is taught in Spanish from the www.datnmt.org website. The study material is available on site and the training is aided by tutors of institutions as CNEA, FUESMEN (School of Nuclear Medicine Foundation), UBA (University of Buenos Aires) and Nuclear Medicine private labs. The DAT-OL is developed in modules: Physics of SPECT / CT and PET / CT; Principles and sectional anatomy CT, SPECT / CT and PET / CT clinical; cyclotron and radiopharmaceutical production; Radiation Safety in PET / CT; Workflows and protocols with PET / CT, clinical reports: normal variants, artifacts and failures. Some of the requirements to take the DAT-OL are: Access to camera PET / CT and / or camera SPECT / CT, and a supervisor (Nuclear Medicine physician or Medical physicist) at the center of NM where the student works. Technicians must have academic qualification, 5 or more years working in centers MN, previous courses in Biology, Physics SPECT and SPECT Clinical course and a Methodology of Radioisotopes and radiation protection course. Results: The first course lasted 12 months including examinations. Tutors have scarcely been consulted. SPECT/CT and PET/CT web examinations, have been developed and evaluated by the authors of the course (B. Hutton and H. Patterson, University of London and

  16. Estimation of the total effective dose from low-dose CT scans and radiopharmaceutical administrations delivered to patients undergoing SPECT/CT explorations

    International Nuclear Information System (INIS)

    Montes, C.; Hernandez, J.; Gomez-Caminero, F.; Garcia, S.; Martin, C.; Rosero, A.; Tamayo, P.

    2013-01-01

    Hybrid imaging, such as single photon emission computed tomography (SPECT)/CT, is used in routine clinical practice, allowing coregistered images of the functional and structural information provided by the two imaging modalities. However, this multimodality imaging may mean that patients are exposed to a higher radiation dose than those receiving SPECT alone. The study aimed to determine the radiation exposure of patients who had undergone SPECT/CT examinations and to relate this to the Background Equivalent Radiation Time (BERT). 145 SPECT/CT studies were used to estimate the total effective dose to patients due to both radiopharmaceutical administrations and low-dose CT scans. The CT contribution was estimated by the Dose-Length Product method. Specific conversion coefficients were calculated for SPECT explorations. The radiation dose from low-dose CTs ranged between 0.6 mSv for head and neck CT and 2.6 mSv for whole body CT scan, representing a maximum of 1 year of background radiation exposure. These values represent a decrease of 80-85% with respect to the radiation dose from diagnostic CT. The radiation exposure from radiopharmaceutical administration varied from 2.1 mSv for stress myocardial perfusion SPECT to 26 mSv for gallium SPECT in patients with lymphoma. The BERT ranged from 1 to 11 years. The contribution of low-dose CT scans to the total radiation dose to patients undergoing SPECT/CT examinations is relatively low compared with the effective dose from radiopharmaceutical administration. When a CT scan is only acquired for anatomical localization and attenuation correction, low-dose CT scan is justified on the basis of its lower dose. (author)

  17. Kombineret ventilations/perfusions-SPECT/CT er bedst til diagnostik af lungeemboli

    DEFF Research Database (Denmark)

    Gutte Borgwardt, Henrik; Mortensen, Jann; Kristoffersen, Ulrik Sloth

    2012-01-01

    The diagnosis of pulmonary embolism (PE) is usually established by a combination of clinical assessment, D-dimer test and imaging with either lung scintigraphy or pulmonary multidetector computed tomography angiography (CTA). Which of the two methods to use in PE diagnostic has not been determined...... and very limited data comparing these modalities are available. With the use of hybrid scanners, ventilation/perfusion-single-photon-emission-tomography (V/Q-SPECT) in combination with low-dose CT without contrast enhancement is feasible and should probably be considered first-line imaging in diagnosing PE....

  18. Noninvasive staging of lung cancer. Indications and limitations of gallium-67 citrate imaging

    International Nuclear Information System (INIS)

    Bekerman, C.; Caride, V.J.; Hoffer, P.B.; Boles, C.A.

    1990-01-01

    The results of evaluation of the hila and mediastinum with 67Ga scans are contradictory, as are the recommendations by different investigators on the use of 67Ga scintigraphy in the clinical evaluation of patients with primary lung carcinoma. Nevertheless, the economy and logistic simplicity of evaluating local and distant metastases with a single imaging procedure are attractive, especially because the symptoms may not enable the physician to make a correct identification of the organ systems affected by metastases. Neumann and Hoffer state that at present conventional Ga-67 scanning techniques cannot be recommended for preoperative staging of mediastinal lymph node metastases in lung cancer patients. According to Waxman, 67Ga scintigraphy, relative to other imaging modalities, is a sensitive indicator of hilar spread of a tumor. However, because of the normally high background activity within the sternum and spine, mediastinal abnormalities may be poorly detected. Since most pulmonary tumors metastasize via regional nodes to the pulmonary hilum and then to the mediastinum, the high sensitivity for the detection of pulmonary hilar abnormalities and the high specificity for detection of mediastinal lesions suggest that gallium scintigraphy is a valuable adjunctive test when used appropriately. The results obtained locally are probably the best guide for individual physicians in the selection of diagnostic tests for their patients. Gallium scans may thus be helpful in the clinical evaluation of patients with lung cancer. Although gallium scans identify mediastinal node involvement, there is considerable controversy over the relationship between the sensitivity and specificity of the method. By detecting distant extrathoracic metastases, the 67Ga scan may identify a small group of patients who can be spared a needless operation. 92 references

  19. SP-ECT imaging and its physical study

    International Nuclear Information System (INIS)

    Kinoshita, Fujimi

    1983-01-01

    Recently, more than a hundred hospitals are provided with SPECT system for clinical examination in Japan. However, a standardization of measuring method and performance test of the systems is ont yet made. We have been studying some basic problems of SPECT system with special phantoms originaly designed by ourselves. We got a conclusion that a standardized phantom is necessary for comparing performances between SPECT systems. In clinical experiences with 3,332 cases, we think that SPECT image combined with conventional image presents much more informations for accurate diagnosis, especially in brain, bone and tumor imagings. Synthesized image of SPECT and XCT, double tracer image and transmission image are useful to visualize the body contour and the clinical diagnosis. (author)

  20. Gallium-67 activated charcoal: a new method for preparation of radioactive capsules for colonic transit study

    International Nuclear Information System (INIS)

    Cheng, Kai-Yuan; Tsai, Shih-Chuan; Lin, Wan-Yu.

    2003-01-01

    Indium-111 is currently the radionuclide of choice for colonic transit study. However, it is expensive and not available in many hospitals. Technetium-99m has been proposed for colonic transit study but the short half-life has limited its use. Gallium-67 citrate is inexpensive and available in most countries. Most importantly, it has a suitable half-life for colonic transit study. Attempts have been made in some studies to use 67 Ga citrate to label activated charcoal, but the results have not been good because of poor stability. In this study, we successfully labelled activated charcoal with 67 Ga citrate by adding alcohol and 5% glucose solution. To evaluate the in vitro stability, the 67 Ga-activated charcoal was incubated in a milieu mimicking the intestinal content, containing lipase, trypsin and glycochenodeoxycholate at different pH values (6.0, 7.0, 7.4 and 8.0) and for different durations (0 h, 24 h, 48 h, 72 h and 96 h). For the in vivo study, the 67 Ga-activated charcoal was loaded into a commercial empty enteric capsule. Colonic transit scintigraphy was performed in five volunteers, including three healthy people and two constipated patients, after intake of the radioactive capsule. Images were obtained at 2 h, 4 h, 6 h, 8 h, 24h, 48 h, 72 h etc. until no radioactivity was detected in the bowel. Our data show that the in vitro stability of 67 Ga-activated charcoal was good. The labelling efficiency still exceeded 91% at 96 h at pH values of 6.0, 7.0 and 7.4. In the group with a pH value of 8.0, the labelling efficiency gradually fell during the 4-day incubation but was still higher than 88% at the end of the fourth day. In the in vivo study, most capsules disintegrated in the caecum/colon region, and the 67 Ga-activated charcoal mixed very well with bowel content. In addition, the radioactive charcoal could be detected clearly on the 72-h image, which is very important for the evaluation of colonic transit time in patients with constipation. In

  1. Development of new folate-based PET radiotracers: preclinical evaluation of 68Ga-DOTA-folate conjugates

    International Nuclear Information System (INIS)

    Fani, Melpomeni; Maecke, Helmut R.; Wang, Xuejuan; Nicolas, Guillaume; Medina, Christelle; Raynal, Isabelle; Port, Marc

    2011-01-01

    A number of 111 In- and 99m Tc-folate-based tracers have been evaluated as diagnostic agents for imaging folate receptor (FR)-positive tumours. A 68 Ga-folate-based radiopharmaceutical would be of great interest, combining the advantages of PET technology and the availability of 68 Ga from a generator. The aim of the study was to develop a new 68 Ga-folate-based PET radiotracer. Two new DOTA-folate conjugates, named P3026 and P1254, were synthesized using the 1,2-diaminoethane and 3-{2-[2-(3-amino-propoxy)-ethoxy]-ethoxy}-propylamine as a spacer, respectively. Both conjugates were labelled with 67/68 Ga. Binding affinity, internalization and externalization studies were performed using the FR-positive KB cell line. Biodistribution and PET/CT imaging studies were performed in nude mice, on a folate-deficient diet, bearing KB and HT1080 (FR-negative) tumours, concurrently. The new radiotracers were evaluated comparatively to the reference molecule 111 In-DTPA-folate ( 111 In-P3139). The K d values of 67/68 Ga-P3026 (4.65 ± 0.82 nM) and 67/68 Ga-P1254 (4.27 ± 0.42 nM) showed high affinity for the FR. The internalization rate followed the order 67/68 Ga-P3026 > 67/68 Ga-P1254 > 111 In-P3139, while almost double cellular retention was found for 67/68 Ga-P3026 and 67/68 Ga-P1254, compared to 111 In-P3139. The biodistribution data of 67/68 Ga-DOTA-folates showed high and receptor-mediated uptake on the FR-positive tumours and kidneys, with no significant differences compared to 111 In-P3139. PET/CT images, performed with 68 Ga-P3026, showed high uptake in the kidneys and clear visualization of the FR-positive tumours. The DOTA-folate conjugates can be efficiently labelled with 68 Ga in labelling yields and specific activities which allow clinical application. The characteristics of the 67/68 Ga-DOTA-folates are comparable to 111 In-DTPA-folate, which has already been used in clinical trials, showing that the new conjugates are promising candidates as PET radiotracers

  2. Interest of the SPECT-CT to D.M.S.A.-V images merging in the management of thyroid medullary carcinomas; Interets de la fusion d'image TEMP-TDM au DMSA-V dans la prise en charge des carcinomes medullaires de la thyroide

    Energy Technology Data Exchange (ETDEWEB)

    Menemani, A.; Mebarki, M.; Slama, A.; Khellil, N.; Meghelli, S.; Lachachi, B.; Krim, M.; Merad, S.; Berber, N. [CHU Tlemcen, Service de medecine nucleaire (Algeria)

    2010-07-01

    Purpose: hybrid imaging associating SPECT and CT, integers functional and anatomical data. The aim of this communication is to present the contribution of the SPECT coupled to CT with D.M.S.A. V. in our daily practice of the medullary thyroid carcinomas management. Conclusions: the SPECT/CT got by a system of images merging allows a better anatomical location and improves the management of thyroid medullary carcinomas. (N.C.)

  3. Motor activation SPECT for the neurosurgical diseases. Clinical application

    International Nuclear Information System (INIS)

    Noguchi, Hiroshi; Kawaguchi, Shoichiro; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime

    1999-01-01

    We evaluated and analyzed the motor activation single photon emission computed tomography (M-SPECT) findings on patients with ischemic cerebrovascular diseases (CVD). The M-SPECT studies were carried out on 91 patients with ischemic cerebrovascular diseases. The M-SPECT study was performed using the finger opposition task in each case. The SPECT images were superimposed on the magnetic resonance images (MRIs) for each case using Image Fusion Software. The result of the M-SPECT was expressed as positive or negative. The cases with a marked increase of blood flow in the sensorio-motor cortex after the finger opposition task were categorized as positive, and those cases showing no marked increase of blood flow were categorized as negative. Among the 91 cases examined, 53 (58%) were categorized as positive in the M-SPECT study. Among the negative M-SPECT cases treated with revascularization surgery, there were some cases showing positive M-SPECT results postoperatively. The cases without any revascularization surgery did not change the M-SPECT findings in each during the follow-up period. The M-SPECT procedure for examining intracranial lesions could provide the cortical localization of the motor function. The M-SPECT procedure in the ischemic CVDs contributes to knowledge about the choices of treatment and the evaluation of the treatment result. (author)

  4. Motor activation SPECT for the neurosurgical diseases. Clinical application

    Energy Technology Data Exchange (ETDEWEB)

    Noguchi, Hiroshi; Kawaguchi, Shoichiro; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime [Nara Medical Univ., Kashihara (Japan)

    1999-08-01

    We evaluated and analyzed the motor activation single photon emission computed tomography (M-SPECT) findings on patients with ischemic cerebrovascular diseases (CVD). The M-SPECT studies were carried out on 91 patients with ischemic cerebrovascular diseases. The M-SPECT study was performed using the finger opposition task in each case. The SPECT images were superimposed on the magnetic resonance images (MRIs) for each case using Image Fusion Software. The result of the M-SPECT was expressed as positive or negative. The cases with a marked increase of blood flow in the sensorio-motor cortex after the finger opposition task were categorized as positive, and those cases showing no marked increase of blood flow were categorized as negative. Among the 91 cases examined, 53 (58%) were categorized as positive in the M-SPECT study. Among the negative M-SPECT cases treated with revascularization surgery, there were some cases showing positive M-SPECT results postoperatively. The cases without any revascularization surgery did not change the M-SPECT findings in each during the follow-up period. The M-SPECT procedure for examining intracranial lesions could provide the cortical localization of the motor function. The M-SPECT procedure in the ischemic CVDs contributes to knowledge about the choices of treatment and the evaluation of the treatment result. (author)

  5. Metabolism of [ 14 C]GA 19 and [ 14 C]GA 53 by ecotypes of Betula ...

    African Journals Online (AJOL)

    Continuing with this line of research, we studied the metabolism of 14C-labelled GA19 and GA53. [14C]GA19 and [14C] A53 were applied to the apices of the northern ecotype (67º N) and to the leaves of the southern ecotype (64º N) of Betula pendula Roth. under different photoperiods and at different times in order to ...

  6. Follow-up of rheumatic carditis using 67Ga-citrate imaging

    International Nuclear Information System (INIS)

    Calegaro, J.U.M.; Bae, S.H.; Prado, E.S.; Gomes, E.F.

    2002-01-01

    Aim: This study reports the follow -up of 25 patients (pts) with rheumatic carditis (9 male, 16 females; 4-29 years, mean 12,12) using 67-gallium citrate. Materials and Methods: the pts were divided in 2 groups: I- first attack (7pts, 2 males, with a mean follow-up of 5,65 years); II- recurrence (18 pts, 7 males, with a mean follow-up of 5,27 years).Images of the thorax and semi quantitative indexes were obtained 72 hours after intravenous injection of 37-74 MBq (1-2 mCi) of 67-gallium citrate, using a LFOV scintillation camera. 67-gallium uptake in the cardiac area was graded as mild, moderate or severe using the tracer uptake in the lung as a reference (normal up to 130%). Results: all pts in group I (2 severe, 2 moderate, and 3 mild carditis) had normal gallium uptake in up to 9 weeks after the institution of cortico therapy, with a better outcome in follow-up.In group II, 8 pts presented moderately active carditis (2 had good and 6 had a poor outcome) and 10 mildly active carditis (7 had good and 3 had poor outcome). The evolution of the disease was better in 8 pts that the reduction of 67- gallium uptake to normal limits occurred in up to 9 weeks, than in 9 pts that the scintigraphy was only normal after 10 weeks of therapy. Conclusion: normal gallium uptake in up to 9 weeks of treatment seems to be a good predictor of evolution in rheumatic carditis first attack or recurrence; in recurrence, reduction of 67-gallium uptake only after 10 weeks or increasing uptake seems to be worse predictors

  7. Radionuclide arthrogram with SPECT/CT for the evaluation of mechanical loosening of hip and knee prostheses

    International Nuclear Information System (INIS)

    Chew, C.G.; Lewis, P.; Middleton, F.; Wijngaard, R. van den; Deshaies, A.

    2010-01-01

    The Objective of this study was to evaluate the value of single photon emission computed tomography (SPECT)/CT in radionuclide arthrogram (RNA) for the assessment of mechanical loosening of hip and knee prostheses. A retrospective audit of 117 RNA SPECT/CTs evaluated by a single reader- 40 hips, (1 hemiarthroplasty) and 77 knees (12 unicompartmental). The detection of any radiotracer within the bone/prosthetic interface was deemed positive for loosening. The operative assessment of 29 hip and 44 knee prosthetic joints was known and used as the gold standard. A subsequent blinded reassessment of the planar images was performed and compared with the SPECT/CT results for 26 of the 29 hip and 42 of the 44 knee prostheses. The respective SPECT/CT versus planar results were as follows: hips- acetabular cup: sensitivity: 73 versus 0%; specificity: 71 versus 100%; positive predictive value: 62% versus indeterminate; negative predictive value: 80% versus 72% (p=0.0044). Hips- femoral component: sensitivity: 78 versus 63%; specificity: 90 versus 94%; positive predictive value: 78 versus 83%; negative predictive value: 90 versus 85% (p=0.2482). Knees- femoral component: sensitivity: 75 versus 17%; specificity 63 versus 97%; positive predictive value: 43 versus 67%; negative predictive value: 87 versus 74% (p=0.0001). Knees- tibial component: sensitivity: 86 versus 63%; specificity: 86 versus 76%; positive predictive value: 55 versus 38%; negative predictive value: 97 versus 90% (p=0.6831). For evaluation of mechanical loosening of the hip prosthesis SPECT/CT was significantly better than planar scanning for the acetabular cup, but not for the femoral stem. For evaluation of the knee prosthesis, a significant improvement was noted using SPECT/CT for the femoral component, and although superior results were also noted for the tibial component, statistical significance was not reached. Taking into account the limitations of this retrospective audit, the value of using RNA SPECT

  8. Applications of cerebral SPECT

    Energy Technology Data Exchange (ETDEWEB)

    McArthur, C., E-mail: claire.mcarthur@nhs.net [Department of Neuroradiology, Institute of Neurological Sciences, Glasgow (United Kingdom); Jampana, R.; Patterson, J.; Hadley, D. [Department of Neuroradiology, Institute of Neurological Sciences, Glasgow (United Kingdom)

    2011-07-15

    Single-photon emission computed tomography (SPECT) can provide three-dimensional functional images of the brain following the injection of one of a series of radiopharmaceuticals that crosses the blood-brain barrier and distributes according to cerebral perfusion, neurotransmitter, or cell density. Applications include differentiating between the dementias, evaluating cerebrovascular disease, preoperative localization of epileptogenic foci, diagnosing movement disorders, and evaluation of intracerebral tumours, while also proving a useful research tool. Unlike positronemission tomography (PET), SPECT imaging is widely available and can be performed in any department that has access to a rotating gamma camera. The purpose of this review is to demonstrate the utility of cerebral SPECT and increase awareness of its role in the investigation of neurological and psychiatric disorders.

  9. SPECT/CT imaging in children with papillary thyroid carcinoma

    International Nuclear Information System (INIS)

    Kim, Hwa-Young; Gelfand, Michael J.; Sharp, Susan E.

    2011-01-01

    SPECT/CT improves localization of single photon-emitting radiopharmaceuticals. To determine the utility of SPECT/CT in children with papillary thyroid carcinoma. 20 SPECT/CT and planar studies were reviewed in 13 children with papillary thyroid carcinoma after total thyroidectomy. Seven studies used I-123 and 13 used I-131, after elevating TSH by T4 deprivation or intramuscular thyrotropin alfa. Eight children had one study and five children had two to four studies. Studies were performed at initial post-total thyroidectomy evaluation, follow-up and after I-131 treatment doses. SPECT/CT was performed with a diagnostic-quality CT unit in 13 studies and a localization-only CT unit in 7. Stimulated thyroglobulin was measured (except in 2 cases with anti-thyroglobulin antibodies). In 13 studies, neck activity was present but poorly localized on planar imaging; all foci of uptake were precisely localized by SPECT/CT. Two additional foci of neck uptake were found on SPECT/CT. SPECT/CT differentiated high neck uptake from facial activity. In six studies (four children), neck uptake was identified as benign by SPECT/CT (three thyroglossal duct remnants, one skin contamination, two by precise anatomical CT localization). In two children, SPECT/CT supported a decision not to treat with I-131. When SPECT/CT was unable to identify focal uptake as benign, stimulated thyroglobulin measurements were valuable. In three of 13 studies with neck uptake, SPECT/CT provided no useful additional information. SPECT/CT precisely localizes neck iodine uptake. In small numbers of patients, treatment is affected. SPECT/CT should be used when available in thyroid carcinoma patients. (orig.)

  10. Radiopharmaceuticals for SPECT cancer detection

    Energy Technology Data Exchange (ETDEWEB)

    Chernov, V. I., E-mail: chernov@oncology.tomsk.ru; Medvedeva, A. A., E-mail: tickayaAA@oncology.tomsk.ru; Zelchan, R. V., E-mail: r.zelchan@yandex.ru; Sinilkin, I. G., E-mail: sinilkinig@oncology.tomsk.ru [Tomsk Cancer Research Institute, Kooperativny Street 5, Tomsk, 634050 (Russian Federation); Tomsk Polytechnic University, Lenin Avenue 30, Tomsk, 634050 (Russian Federation); Stasyuk, E. S.; Larionova, L. A. [Tomsk Polytechnic University, Lenin Avenue 30, Tomsk, 634050 (Russian Federation); Slonimskaya, E. M.; Choynzonov, E. L. [Tomsk Cancer Research Institute, Kooperativny Street 5, Tomsk, 634050 (Russian Federation)

    2016-08-02

    The purpose of the study was to assess the efficacy of single photon emission computed tomography (SPECT) with {sup 199}Tl and {sup 99}mTc-MIBI in the detection of breast, laryngeal and hypopharyngeal cancers. A total of 220 patients were included into the study: 120 patients with breast lesions (100 patients with breast cancer and 20 patients with benign breast tumors) and 100 patients with laryngeal/hypopharyngeal diseases (80 patients with laryngeal/hypopharyngeal cancer and 20 patients with benign laryngeal/hypopharyngeal lesions). No abnormal {sup 199}Tl uptake was seen in all patients with benign breast and laryngeal lesions, indicating a 100% specificity of {sup 199}Tl SPECT. In the breast cancer patients, the increased {sup 199}Tl uptake in the breast was visualized in 94.8% patients, {sup 99m}Tc-MIBI—in 93.4% patients. The increased {sup 199}Tl uptake in axillary lymph nodes was detected in 60% patients, and {sup 99m}Tc-MIBI—in 93.1% patients. In patients with laryngeal/hypopharyngeal cancer, the sensitivity of SPECT with {sup 199}Tl and {sup 99m}Tc-MIBI was 95%. The {sup 199}Tl SPECT sensitivity in identification of regional lymph node metastases in the patients with laryngeal/hypopharyngeal cancer was 75% and the {sup 99m}Tc-MIBI SPECT sensitivity was 17%. The data obtained showed that SPECT with {sup 199}Tl and {sup 99m}Tc-MIBI can be used as one of the additional imaging methods in detection of tumors.

  11. Measurement of lower hybrid hot spots using a retarding field analyzer in Tore Supra

    Czech Academy of Sciences Publication Activity Database

    Gunn, J. P.; Petržílka, Václav; Ekedahl, A.; Fuchs, Vladimír; Gauthier, E.; Goniche, M.; Kočan, M.; Pascal, J.Y.; Saint Laurent, F.

    390-391, č. 1 (2009), s. 904-906 ISSN 0022-3115. [International Conference on Plasma-Surface Interactions in Controlled Fusion Devices/18th./. Toledo, 26.05.2008-30.5.2008] R&D Projects: GA ČR GA202/07/0044 Institutional research plan: CEZ:AV0Z20430508 Keywords : Lower Hybrid * hot spots * ELECTRONS * POWER Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.933, year: 2009 http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6TXN-4VG7MW6-7&_user=6542793&_rdoc=1&_fmt=&_orig=search&_sort=d&_docanchor=&view=c&_acct=C000070123&_version=1&_urlVersion=0&_userid=6542793&md5=944ed4d95df86a149fa36439db6215db

  12. Significance of delayed /sup 99m/Tc-PMT scintigraphy in diagnosis of hepatocellular carcinoma. Comparison between /sup 99m/Tc-PMT and /sup 67/Ga-citrate scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, Yoshihisa; Nakano, Shunichi; Hashizume, Terumi and others

    1985-03-01

    The usefulness of delayed hepatobiliary imaging with /sup 99m/Tc-PMT in diagnosis of hepatocellular carcinoma was studied in 30 patients with histologically verified hepatocellular carcinoma. Of 30 patients, delayed /sup 99m/Tc-PMT images showed 13 patients (43 %) of increased radioactivity and 4 (13 %) of equilibrated radioactivity in carcinoma as compared with that in the surrounding normal liver tissues. Furthermore, 3 of 6 patients who showed no filling defects in /sup 99m/Tc-Sn colloid liver images, showed increased uptake of radioactivity in carcinoma in delayed /sup 99m/Tc-PMT images. These results suggest that the complementary use of delayed /sup 99m/Tc-PMT imaging to /sup 99m/Tc-Sn colloid liver imaging is useful for detecting hepatoma lesions. The hepatic lesions were positively visualized on /sup 99m/Tc-PMT and/or /sup 67/Ga-citrate images in 21 (70 %) of 30 patients. These results indicate that use of delayed /sup 99m/Tc-PMT and /sup 67/Ga-citrate imaging in combination is useful for positive visualization of hepatocellular carcinoma.

  13. SPECT of the brain: Present and future

    International Nuclear Information System (INIS)

    Fazio, F.; Lenzi, G.L.

    1986-01-01

    In both PET and SPECT, most of the studies and the models have been addressed to two organs: brain and heart. So far, brain has certainly been investigated more. The several comparisons between planar scintigraphy and SPECT, between X-ray TCT and SPECT, and also between PET and SPECT, have tended to consider SPECT a cheap but scarcely useful tool for a nuclear medicine section. Again the authors feel that this is due to the fact that SPECT is really a ''physiological tomography'', with little known about its physiology or how it is measured. Thus the present state of the art of SPECT of the brain is characterized by a collection of data and reports on brain imaging and by a slowly growing basic understanding of the utilized modes. The introduction of a new brain-imaging radiopharmaceutical is immediately signaled by its ''first clinical application'' without parallel studies on the kinetics, the metabolic degradation, and the real suitability of the molecule as a tracer for measurement of regional CBF. Only a few attempts seek to narrow this discussion between clinic and biology, and the authors like to emphasize the need for nuclear medicine people to dedicate more time and effort

  14. 123I-iomazenil brain receptor SPECT in focal epilepsy. In comparison with 99mTc-HMPAO brain SPECT, MRI and Video/EEG monitoring

    International Nuclear Information System (INIS)

    Xu Hao; Wang Tongge; Huang Li; Michael Cordes

    1998-01-01

    Purpose: To evaluate the clinical value of 123 I-Iomazenil brain receptor SPECT in diagnosis of focal epilepsy in comparison with 99m Tc-HMPAO brain SPECT, MRI and Video/EEG monitoring. Methods 123 I-Iomazenil brain receptor SPECT was performed on 40 patients with focal epilepsy. The results were compared with those obtained by 99m Tc-HMPAO brain SPECT, MRI and Video/EEG monitoring. Results: In 40 patients, the sensitivity of Video/EEG monitoring for localization of epileptogenic area was 95% (38/40). The sensitivity of 123 I-iomazenil brain receptor SPECT, 99m Tc-HMPAO brain SPECT and MRI for localization of epileptogenic area compared with Video/EEG monitoring ('gold standard') was 65.8%(25/38), 55.3%(21/38) and 47.4%(18/38), respectively. The localization of epileptogenic area with 123 I-Iomazenil brain receptor SPECT was in concordance with Video/EEG monitoring in 20 patients, 99m Tc-HMPAO brain SPECT in 15 patients and MRI in 16 patients, respectively. The sensitivity of 123 I-Iomazenil brain receptor SPECT combined with MRI for localization of epileptogenic area was 84.2%(32/38). Conclusions: 123 I-Iomazenil brain receptor SPECT is a useful method in detecting and localizing epileptogenic area. The combination of 123 I-Iomazenil brain receptor SPECT and MRI has a high sensitivity for detecting epileptogenic area

  15. Combined SPECT/CT improves detection of initial bone invasion and determination of resection margins in squamous cell carcinoma of the head and neck compared to conventional imaging modalities

    Energy Technology Data Exchange (ETDEWEB)

    Kolk, A. [Technische Universitaet Muenchen, Klinikum rechts der Isar, Department of Oral and Maxillofacial Surgery, Munich (Germany); Klinikum rechts der Isar, Technische Universitaet Muenchen, Klinik und Poliklinik fuer Mund-Kiefer und Gesichtschirurgie, Muenchen (Germany); Schuster, T. [Technische Universitaet Muenchen, Klinikum rechts der Isar, Institute of Medical Statistics and Epidemiology, Munich (Germany); Chlebowski, A.; Kesting, M.; Bissinger, O.; Weitz, J. [Technische Universitaet Muenchen, Klinikum rechts der Isar, Department of Oral and Maxillofacial Surgery, Munich (Germany); Lange, P. [Technische Universitaet Muenchen, Klinikum rechts der Isar, Department of Diagnostic Radiology, Munich (Germany); Scheidhauer, K.; Schwaiger, M.; Dinges, J. [Technische Universitaet Muenchen, Klinikum rechts der Isar, Department of Nuclear Medicine, Munich (Germany)

    2014-07-15

    Knowledge of the presence and extent of bone infiltration is crucial for planning the resection of potential bone-infiltrating squamous cell carcinomas of the head and neck (HNSCC). Routinely, plain-film radiography, multislice computed tomography (MSCT) and magnetic resonance imaging (MRI) are used for preoperative staging, but they show relatively high rates of false-positive and false-negative findings. Scintigraphy with {sup 99m}Tc-bisphosphonate has the ability to show increased metabolic bone activity. If combined with anatomical imaging (e.g. (SPECT)/CT), it facilitates the precise localization of malignant bone lesions. The aim of this study was to analyse the indications and advantages of SPECT/CT compared with standard imaging modalities and histology with regard to specificity and sensitivity A longitudinally evaluated group of 30 patients with biopsy-proven HNSCC adjacent to the mandible underwent {sup 99m}Tc-bisphosphonate SPECT/CT, MRI, MSCT and conventional radiography before partial or rim resection of the mandible was performed. Bone infiltration was first evaluated with plain films, MSCT and MRI. In a second reading, SPECT/CT data were taken into account. The results (region and certainty of bone invasion) were evaluated among the different imaging modalities and finally compared with histological specimens from surgical resection as the standard of reference. For a better evaluation of the hybrid property of SPECT/CT, a retrospectively evaluated group of 20 additional patients with tumour locations similar to those of the longitudinally examined SPECT/CT group underwent SPECT, MSCT and MRI. To assess the influence of dental foci on the specificity of the imaging modalities, all patients were separated into two subgroups depending on the presence or absence of teeth in the area of potential tumour-bone contact. Histologically proven bone infiltration was found in 17 patients (57 %) when analysed by conventional imaging modalities. SPECT/CT data

  16. Combined SPECT/CT improves detection of initial bone invasion and determination of resection margins in squamous cell carcinoma of the head and neck compared to conventional imaging modalities

    International Nuclear Information System (INIS)

    Kolk, A.; Schuster, T.; Chlebowski, A.; Kesting, M.; Bissinger, O.; Weitz, J.; Lange, P.; Scheidhauer, K.; Schwaiger, M.; Dinges, J.

    2014-01-01

    Knowledge of the presence and extent of bone infiltration is crucial for planning the resection of potential bone-infiltrating squamous cell carcinomas of the head and neck (HNSCC). Routinely, plain-film radiography, multislice computed tomography (MSCT) and magnetic resonance imaging (MRI) are used for preoperative staging, but they show relatively high rates of false-positive and false-negative findings. Scintigraphy with 99m Tc-bisphosphonate has the ability to show increased metabolic bone activity. If combined with anatomical imaging (e.g. (SPECT)/CT), it facilitates the precise localization of malignant bone lesions. The aim of this study was to analyse the indications and advantages of SPECT/CT compared with standard imaging modalities and histology with regard to specificity and sensitivity A longitudinally evaluated group of 30 patients with biopsy-proven HNSCC adjacent to the mandible underwent 99m Tc-bisphosphonate SPECT/CT, MRI, MSCT and conventional radiography before partial or rim resection of the mandible was performed. Bone infiltration was first evaluated with plain films, MSCT and MRI. In a second reading, SPECT/CT data were taken into account. The results (region and certainty of bone invasion) were evaluated among the different imaging modalities and finally compared with histological specimens from surgical resection as the standard of reference. For a better evaluation of the hybrid property of SPECT/CT, a retrospectively evaluated group of 20 additional patients with tumour locations similar to those of the longitudinally examined SPECT/CT group underwent SPECT, MSCT and MRI. To assess the influence of dental foci on the specificity of the imaging modalities, all patients were separated into two subgroups depending on the presence or absence of teeth in the area of potential tumour-bone contact. Histologically proven bone infiltration was found in 17 patients (57 %) when analysed by conventional imaging modalities. SPECT/CT data revealed

  17. Investigation of dynamic SPECT measurements of the arterial input function in human subjects using simulation, phantom and human studies

    Science.gov (United States)

    Winant, Celeste D.; Aparici, Carina Mari; Zelnik, Yuval R.; Reutter, Bryan W.; Sitek, Arkadiusz; Bacharach, Stephen L.; Gullberg, Grant T.

    2012-01-01

    Computer simulations, a phantom study and a human study were performed to determine whether a slowly rotating single-photon computed emission tomography (SPECT) system could provide accurate arterial input functions for quantification of myocardial perfusion imaging using kinetic models. The errors induced by data inconsistency associated with imaging with slow camera rotation during tracer injection were evaluated with an approach called SPECT/P (dynamic SPECT from positron emission tomography (PET)) and SPECT/D (dynamic SPECT from database of SPECT phantom projections). SPECT/P simulated SPECT-like dynamic projections using reprojections of reconstructed dynamic 94Tc-methoxyisobutylisonitrile (94Tc-MIBI) PET images acquired in three human subjects (1 min infusion). This approach was used to evaluate the accuracy of estimating myocardial wash-in rate parameters K1 for rotation speeds providing 180° of projection data every 27 or 54 s. Blood input and myocardium tissue time-activity curves (TACs) were estimated using spatiotemporal splines. These were fit to a one-compartment perfusion model to obtain wash-in rate parameters K1. For the second method (SPECT/D), an anthropomorphic cardiac torso phantom was used to create real SPECT dynamic projection data of a tracer distribution derived from 94Tc-MIBI PET scans in the blood pool, myocardium, liver and background. This method introduced attenuation, collimation and scatter into the modeling of dynamic SPECT projections. Both approaches were used to evaluate the accuracy of estimating myocardial wash-in parameters for rotation speeds providing 180° of projection data every 27 and 54 s. Dynamic cardiac SPECT was also performed in a human subject at rest using a hybrid SPECT/CT scanner. Dynamic measurements of 99mTc-tetrofosmin in the myocardium were obtained using an infusion time of 2 min. Blood input, myocardium tissue and liver TACs were estimated using the same spatiotemporal splines. The spatiotemporal maximum

  18. Investigation of dynamic SPECT measurements of the arterial input function in human subjects using simulation, phantom and human studies

    International Nuclear Information System (INIS)

    Winant, Celeste D; Aparici, Carina Mari; Bacharach, Stephen L; Gullberg, Grant T; Zelnik, Yuval R; Reutter, Bryan W; Sitek, Arkadiusz

    2012-01-01

    Computer simulations, a phantom study and a human study were performed to determine whether a slowly rotating single-photon computed emission tomography (SPECT) system could provide accurate arterial input functions for quantification of myocardial perfusion imaging using kinetic models. The errors induced by data inconsistency associated with imaging with slow camera rotation during tracer injection were evaluated with an approach called SPECT/P (dynamic SPECT from positron emission tomography (PET)) and SPECT/D (dynamic SPECT from database of SPECT phantom projections). SPECT/P simulated SPECT-like dynamic projections using reprojections of reconstructed dynamic 94 Tc-methoxyisobutylisonitrile ( 94 Tc-MIBI) PET images acquired in three human subjects (1 min infusion). This approach was used to evaluate the accuracy of estimating myocardial wash-in rate parameters K 1 for rotation speeds providing 180° of projection data every 27 or 54 s. Blood input and myocardium tissue time-activity curves (TACs) were estimated using spatiotemporal splines. These were fit to a one-compartment perfusion model to obtain wash-in rate parameters K 1 . For the second method (SPECT/D), an anthropomorphic cardiac torso phantom was used to create real SPECT dynamic projection data of a tracer distribution derived from 94 Tc-MIBI PET scans in the blood pool, myocardium, liver and background. This method introduced attenuation, collimation and scatter into the modeling of dynamic SPECT projections. Both approaches were used to evaluate the accuracy of estimating myocardial wash-in parameters for rotation speeds providing 180° of projection data every 27 and 54 s. Dynamic cardiac SPECT was also performed in a human subject at rest using a hybrid SPECT/CT scanner. Dynamic measurements of 99m Tc-tetrofosmin in the myocardium were obtained using an infusion time of 2 min. Blood input, myocardium tissue and liver TACs were estimated using the same spatiotemporal splines. The spatiotemporal

  19. The diagnostic value of Tc-99m PYP, Tl-201 dual isotope SPECT to predict the viability of damaged myocardium in the acute phase of myocardial infarction

    International Nuclear Information System (INIS)

    Matsuo, Hitoshi; Watanabe, Sachiro; Arai, Masazumi

    1991-01-01

    To assess the diagnostic value of Tc-99m pyrophosphate (PYP), Tl-201 dual isotope SPECT for the evaluation of myocardial viability, segmental comparison between dual isotope SPECT and exercise, delayed, and reinjected Tl study were performed with 18 acute myocardial infarction (AMI) patients. Among 72 damaged myocardial segments, 48 segments (67%) were judged as viable by chronic phase Tl studies. The segments with severely reduced Tl uptake by dual SPECT showed significantly lower prevalence of viable myocardium than the segments with reduced and normal Tl uptake (p<0.001). The segments with PYP accumulation localized to the subendocardium represented the favorable outcome compared with the transmural accumulation (p<0.001). And overlap segments show better prognosis than the segments without overlap (p<0.05). Most importantly, we can get better predictive accuracy of myocardial scar by dual isotope SPECT than the judgement by Tl or PYP SPECT alone (83.3% vs 77.8%, 68.1%). Thus, we conclude that Tc-99m PYP, Tl-201 dual isotope SPECT is useful to assess the severity of myocardial damage in the acute phase of myocardial infarction. (author)

  20. In vivo quantification of {sup 177}Lu with planar whole-body and SPECT/CT gamma camera imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, Dale L. [Department of Nuclear Medicine, Royal North Shore Hospital, St Leonards, NSW 2065 (Australia); Faculty of Health Sciences, University of Sydney, Cumberland, NSW (Australia); Sydney Medical School, University of Sydney, Camperdown, NSW (Australia); NETwork, Sydney Vital, St Leonards, Sydney, NSW (Australia); Hennessy, Thomas M.; Willowson, Kathy P.; Henry, E. Courtney [Institute of Medical Physics, University of Sydney, Camperdown, NSW (Australia); Chan, David L.H. [Department of Nuclear Medicine, Royal North Shore Hospital, St Leonards, NSW 2065 (Australia); NETwork, Sydney Vital, St Leonards, Sydney, NSW (Australia); Aslani, Alireza [Department of Nuclear Medicine, Royal North Shore Hospital, St Leonards, NSW 2065 (Australia); Roach, Paul J. [Department of Nuclear Medicine, Royal North Shore Hospital, St Leonards, NSW 2065 (Australia); Sydney Medical School, University of Sydney, Camperdown, NSW (Australia)

    2015-09-17

    Advances in gamma camera technology and the emergence of a number of new theranostic radiopharmaceutical pairings have re-awakened interest in in vivo quantification with single-photon-emitting radionuclides. We have implemented and validated methodology to provide quantitative imaging of {sup 177}Lu for 2D whole-body planar studies and for 3D tomographic imaging with single-photon emission computed tomography (SPECT)/CT. Whole-body planar scans were performed on subjects to whom a known amount of [{sup 177}Lu]-DOTA-octreotate had been administered for therapy. The total radioactivity estimated from the images was compared with the known amount of the radionuclide therapy administered. In separate studies, venous blood samples were withdrawn from subjects after administration of [{sup 177}Lu]-DOTA-octreotate while a SPECT acquisition was in progress and the concentration of the radionuclide in the venous blood sample compared with that estimated from large blood pool structures in the SPECT reconstruction. The total radioactivity contained within an internal SPECT calibration standard was also assessed. In the whole-body planar scans (n = 28), the estimated total body radioactivity was accurate to within +4.6 ± 5.9 % (range −17.1 to +11.2 %) of the correct value. In the SPECT reconstructions (n = 12), the radioactivity concentration in the cardiac blood pool was accurate to within −4.0 ± 7.8 % (range −16.1 to +7.5 %) of the true value and the internal standard measurements (n = 89) were within 2.0 ± 8.5 % (range −16.3 to +24.2 %) of the known amount of radioactivity contained. In our hands, state-of-the-art hybrid SPECT/CT gamma cameras were able to provide accurate estimates of in vivo radioactivity to better than, on average, ±10 % for use in biodistribution and radionuclide dosimetry calculations.

  1. The Effect and Side Effect of Dipyridamole in Myocardial SPECT

    International Nuclear Information System (INIS)

    Yang, Hyung In; Lee, Dong Soo; Yeo, Jeong Suk; Bae, Sang Kyun; Choi, Chang Woon; Chung, June Key; Lee, Myung Chul; Koh, Chang Soon

    1993-01-01

    Dipyridamole is an agent that may be used to noninvasively evaluate coronary artery disease. The effect of dipyridamole infusion its generally related to its induced peripheral vasodilatory effect. In normal person, heart rate is generally increased slightly while blood pressure decrease, but the achieved double product and related myocardial oxygen consumption have no significant change. The purpose of this study is to examine the effect and side effect of dipyridamole, and to compare different response to dipyridamole among the patients. We evaluated 847 patients who underwent dipyridamole stress myocardial SPECT. 93.6% of them had induced hypotension 0.9% showed no change of blood pressure, 5.5% had increased blood pressure 8.3% had no change of pulse rate more than 10% of basal pulse rate. Among diabetes, 16.9% was not change of pulse rate, 6.7% in non-diabetes. There was no significant correlation between age and rate pressure product rest(RPPr), in patients without perfusion defects on SPECT(y=7.1x+48.4r=0.13 p>0.01). As increasing age, RPPs/RPPr was declined(y=-11.6x+68.9 r=0.17 p<0.01), similar results were obtained in patients with perfusion defect. The size of perfusion defect on myocardial SPECT have no correlation between RPPr and RPPs/RPPr. The side effects of dipyridamole included chest pain and chest tightness, headache, abdominal pain, dizziness, nausea, and dyspnea. As increasing age, dipyridamole-induced cardiac work at rest was increased, cardiac response to dipyridamole was decreased.

  2. Mnemonic activation by SPECT

    International Nuclear Information System (INIS)

    Migneco, O.; Darcourt, J.; Benoit, M; Malandain, G.; Thirion, J.P.; Robert, Ph.; Vidal, R.; Desvignes, Ph.; Benoliel, J.; Ayache, N.; Bussiere, F.

    1997-01-01

    Data of literature show that SPECT is able to detect cerebral activations induced by sensory-motor stimuli. The facts are not clearly established in what concerns the cognitive activations the amplitude of which is lower. We have studied an activation paradigm such as the Grober and Bruschke test which implies the long term explicit memory. It comprises a visual presentation of words followed by their indexed recall. By using a two-day protocol, 2 SPECTs were achieved in 4 healthy right-handed voluntaries as follows: one of activation (A) and one of control (B). The fifth subject benefited by a SPECT B and of an MRI. The injection for the examination A has been done during the indexed recall stage and for the examination B at the moment when the patient repeated several times the same 3 words. The SPECT data were collected 1 hour after the injection of 370 MBq of ECD making use of a 3-head camera equipped with UHR fan collimators and ending by a LMH on the reconstructed images of 8 mm. The MRI has been achieved by means of a Signa 1.5 Tesla magnet. The SPECT A and B of the subjects 1 to 4 were matched elastically to that of the subject 5 and that of the subject 5 was rigidly matched on its MRI. In this way the individual activation cards of the 4 subjects could be averaged and superimposed on the MRI of the 5. subject. One observes an internal temporal activation (maximal activation of left tonsil, +25% and right uncus, +23%) and a right cingulum activation (maximal activation, +25%), in agreement with the neuro-physiological data. The elastic matching makes possible the inter-subject averaging, what increases the signal-to-noise ratio of activation. The inter-modality rigid matching facilitates the anatomical localisation of the activation site. With these adapted tools, the cognitive activation is thus possible by SPECT and opens perspectives for early diagnosis of neurological troubles, namely of Alzheimer's disease

  3. Is there any advantage from the hybrid imaging diagnostic?

    International Nuclear Information System (INIS)

    Kostadinova, I.

    2012-01-01

    The hybrid imaging methods- Single Photon Emission Tomography-Computer Tomography / SPECT-CT / and Positron Emission Tomography-Computer Tomography / PET-CT/ allow receiving of combined image of two different techniques. In such a way it is possible to superimpose detailed anatomical image of the multislice spiral computer tomography with specific and sensitive molecular images of the SPECT and PET in a single study, allowing utilization of the full possibilities of the both techniques. They have advantages and disadvantages, which basically stem from the differences in the used radiopharmaceuticals and their physical properties. In PET-CT-positron emitters are applied, most often 18F and 11C, while-in SPECT-CT - single photon emitters, most often 99mTc and 131I. A disadvantage of PET is a high cost, which is produced in cyclotron and its logistics is complicated. The great advantage of PET is its better spatial resolution, compared to SPECT, because of the possibility to for simultaneous detection of pared photons and better registration. These techniques, especially PET-CT are nowadays the most increasing imaging methods in the world in making diagnosis, staging and following the effect of treatment in patients with oncological, neurological, cardiological, orthopedic diseases and infections. Recently, they are applied for the purposes of radiotherapy planning on the basis of the metabolically active tumour. As a final result, compared to the conventional techniques- roentgenography, computer tomography and magnetic resonance imaging, it is possible in many cases to make an early and more precise diagnosis and to safe time for the patient for adequate treatment. As a conclusion it is clear, that the hybrid imaging has future and its application will increase in future

  4. Bismuth alloying properties in GaAs nanowires

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Lu [State Key Laboratory of Information Photonics and Optical Communications, Ministry of Education, Beijing University of Posts and Telecommunications, PO Box 72, Beijing 100876 (China); Lu, Pengfei, E-mail: photon.bupt@gmail.com [State Key Laboratory of Information Photonics and Optical Communications, Ministry of Education, Beijing University of Posts and Telecommunications, PO Box 72, Beijing 100876 (China); Cao, Huawei; Cai, Ningning; Yu, Zhongyuan [State Key Laboratory of Information Photonics and Optical Communications, Ministry of Education, Beijing University of Posts and Telecommunications, PO Box 72, Beijing 100876 (China); Gao, Tao [Institute of Atomic and Molecular Physics, Sichuan University, Chengdu 610065 (China); Wang, Shumin [State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050 (China); Photonics Laboratory, Department of Microtechnology and Nanoscience, Chalmers University of Technology, 41296 Gothenburg (Sweden)

    2013-09-15

    First-principles calculations have been performed to investigate the structural, electronic and optical properties of bismuth alloying in GaAs nanowires. A typical model of Ga{sub 31}As{sub 31} nanowires is introduced for its reasonable band gap. The band gap of GaAs{sub 1−x}Bi{sub x} shrinks clearly with the increasing Bi concentration and the band edge shifts when spin–orbit coupling (SOC) is considered. The insertion of Bi atom leads to hybridization of Ga/As/Bi p states which contributes a lot around Fermi level. Scissor effect is involved. The optical properties are presented, including dielectric function, optical absorption spectra and reflectivity, which are also varied with the increasing of Bi concentrations. - Graphical abstract: Top view of Bi-doped GaAs nanowires. Ga, As, and Bi atoms are denoted with grey, purple and red balls, respectively. Display Omitted - Highlights: • A typical model of Ga{sub 31}As{sub 31} nanowires is introduced for its reasonable band gap. • The band gap of GaAs{sub 1−x}Bi{sub x} shrinks clearly with the increasing Bi concentration. • The band edge shifts when spin–orbit coupling (SOC) is considered. • The insertion of Bi atom leads to hybridization of Ga/As/Bi p states.

  5. SPECT quantification of regional radionuclide distributions

    International Nuclear Information System (INIS)

    Jaszczak, R.J.; Greer, K.L.; Coleman, R.E.

    1986-01-01

    SPECT quantification of regional radionuclide activities within the human body is affected by several physical and instrumental factors including attenuation of photons within the patient, Compton scattered events, the system's finite spatial resolution and object size, finite number of detected events, partial volume effects, the radiopharmaceutical biokinetics, and patient and/or organ motion. Furthermore, other instrumentation factors such as calibration of the center-of-rotation, sampling, and detector nonuniformities will affect the SPECT measurement process. These factors are described, together with examples of compensation methods that are currently available for improving SPECT quantification. SPECT offers the potential to improve in vivo estimates of absorbed dose, provided the acquisition, reconstruction, and compensation procedures are adequately implemented and utilized. 53 references, 2 figures

  6. Radionuclide cisternography: SPECT and 3D-rendering. Radionuklidzisternographie: SPECT- und 3D-Technik

    Energy Technology Data Exchange (ETDEWEB)

    Henkes, H; Huber, G; Piepgras, U [Universitaet des Saarlandes, Homburg/Saar (Germany, F.R.). Abt. fuer Neuroradiologie; Hierholzer, J [Freie Univ. Berlin (Germany, F.R.). Strahlenklinik und Poliklinik; Cordes, M [British Columbia Univ., Vancouver, BC (Canada). Belzberg Lab. of Neuroscience

    1991-10-01

    Radionuclide cisternography is indicated in the clinical work-up for hydrocephalus, when searching for CSF leaks, and when testing whether or not intracranial cystic lesions are communicating with the adjacent subarachnoid space. This paper demonstrates the feasibility and diagnostic value of SPECT and subsequent 3D surface rendering in addition to conventional rectilinear CSF imaging in eight patients. Planar images allowed the evaluation of CSF circulation and the detection of CSF fistula. They were advantageous in examinations 48 h after application of {sup 111}In-DTPA. SPECT scans, generated 4-24 h after tracer application, were superior in the delineation of basal cisterns, especially in early scans; this was helpful in patients with pooling due to CSF fistula and in cystic lesions near the skull base. A major drawback was the limited image quality of delayed scans, when the SPECT data were degraded by a low count rate. 3D surface rendering was easily feasible from SPECT data and yielded high quality images. The presentation of the spatial distribution of nuclide-contaminated CSF proved especially helpful in the area of the basal cisterns. (orig.).

  7. Design of common software for quality control of SPECT

    International Nuclear Information System (INIS)

    Li Xiaohua; Gao Ruzhen; Chen Shengzu

    1993-01-01

    The goal of this study is to design a common testing system for SPECT quality control according to NEMA standard. Using the system, the performances of different types of SPECT can be tested, so that the acceptance testing, performance comparing and routine quality control for SPECT can be normalized. The system was based on IBM PC series of microcomputer. Testing data are acquired from various types of SPECT, then transferred into IBM PC through interface and tested with an unique testing program. Two parts were included: interface and SPECT testing program. It emphatically studied the managing program of RS232 interface, designing skills and the mathematic patterns of SPECT testing program. The system which was composed of 11 subroutines can be used to measure the performances for both gamma camera and SPECT. The system was tested on OMEGA 500/MCS 560 SPECT and the results showed that it is effective, accurate and easy to use

  8. Myocardial perfusion SPECT 2015 in Germany. Results of the 7th survey.

    Science.gov (United States)

    Lindner, Oliver; Burchert, Wolfgang; Schäfer, Wolfgang; Hacker, Marcus

    2017-02-14

    The working group Cardiovascular Nuclear Medicine of the German Society of Nuclear Medicine presents the results of the 7th survey of myocardial perfusion SPECT (MPS) of the reporting year 2015. 268 questionnaires (173 practices [PR], 67 hospitals [HO], 28 university hospitals [UH]) were evaluated. Results of the last survey from 2012 are set in squared brackets. MPS of 121 939 [105 941] patients were reported. 98 % [95 %] of all MPS were performed with Tc-99m radiopharmaceuticals and 2 % [5 %] with Tl-201. 78 % [79 %] of all patients were studied in PR, 14 % [15 %] in HO, and 8 % [6 %] in UH. A pharmacological stress test was performed in 43 % [39 %] (22 % [24 %] adenosine, 20 % [9 %] regadenoson, 1 % [6 %] dipyridamole or dobutamine). Attenuation correction was applied in 25 % [2009: 10 %] of MPS. Gated SPECT was performed in 78 % [70 %] of all rest MPS, in 80 % [73 %] of all stress and in 76 % [67 %] of all stress and rest MPS. 53 % [33 %] of all nuclear medicine departments performed MPS scoring by default, whereas 24 % [41 %] did not apply any quantification. 31 % [26 %] of all departments noticed an increase in their counted MPS and 29 % [29 %] no changes. Data from 89 departments which participated in all surveys showed an increase in MPS count of 11.1 % (PR: 12.2 %, HO: 4.8 %, UH: 18.4 %). 70 % [60 %] of the MPS were requested by ambulatory care cardiologists. The 2015 MPS survey reveals a high-grade adherence of routine MPS practice to current guidelines. The positive trend in MPS performance and number of MPS already observed in 2012 continues. Educational training remains necessary in the field of SPECT scoring.

  9. SPECT and PET imaging in epilepsy

    International Nuclear Information System (INIS)

    Semah, F.

    2007-01-01

    Positron emission tomography (PET) and single photon emission computed tomography (SPECT) imaging are very useful for the management of patients with medically refractory partial epilepsy. Presurgical evaluation of patients with medically refractory partial epilepsy often included PET imaging using FDG. The use of SPECT in these patients adds some more information and gives the clinicians the possibility of having ictal imaging. Furthermore, PET and SPECT imaging are performed to better understand the pathophysiology of epilepsy. (authors)

  10. Brain spect imaging

    International Nuclear Information System (INIS)

    Lee, R.G.L.; Hill, T.C.; Holman, B.L.

    1989-01-01

    This paper discusses how the rapid development of single-photon radiopharmaceuticals has given new life to tomographic brain imaging in nuclear medicine. Further developments in radiopharmaceuticals and refinements in neuro-SPECT (single-photon emission computed tomography) instrumentation should help to reinstate brain scintigraphy as an important part of neurologic diagnosis. SPECT of the brain evolved from experimentation using prototype instrumentation during the early 1960s. Although tomographic studies provided superior diagnostic accuracy when compared to planar techniques, the arrival of X-ray CT of the head resulted in the rapid demise of technetium brain imaging

  11. Strong correlation and ferromagnetism in (Ga,Mn)As and (Ga,Mn)N

    International Nuclear Information System (INIS)

    Filippetti, A.; Spaldin, N.A.; Sanvito, S.

    2005-01-01

    The band energies of the ferromagnetic diluted magnetic semiconductors (Ga,Mn)As and (Ga,Mn)N are calculated using a self-interaction-free approach which describes covalent and strongly correlated electrons without adjustable parameters. Both materials are half-metallic, although the contribution of Mn-derived d states to the bands around the Fermi energy is very different in the two cases. In (Ga,Mn)As the bands are strongly p-d hybridized, with a dominance of As p states. In contrast in (Ga,Mn)N the Fermi energy lies within three flat bands of mainly d character that are occupied by two electrons. Thus the Mn ion in (Ga,Mn)N behaves as a deep trap acceptor, with the hole at 1.39 eV above the GaN valence band top, and is in excellent agreement with the experimental data

  12. Highly reliable photosensitive organic-inorganic hybrid passivation layers for a-InGaZnO thin-film transistors

    Science.gov (United States)

    Bermundo, Juan Paolo; Ishikawa, Yasuaki; Yamazaki, Haruka; Nonaka, Toshiaki; Fujii, Mami N.; Uraoka, Yukiharu

    2015-07-01

    We report the fabrication of a photosensitive hybrid passivation material on amorphous InGaZnO (a-IGZO) thin-film transistors (TFTs) that greatly enhance its stability and improve its electrical characteristics. The hybrid passivation based on polysilsesquioxane is transparent and fabricated using a simple solution process. Because the passivation is photosensitive, dry etching was never performed during TFT fabrication. TFTs passivated with this material had a small threshold voltage shift of 0.5 V during positive bias stress, 0.5 V during negative bias stress, and -2.5 V during negative bias illumination stress. Furthermore, TFTs passivated by this layer were stable after being subjected to high relative humidity stress — confirming the superb barrier ability of the passivation. Analysis of secondary ion mass spectrometry showed that a large amount of hydrogen, carbon, and fluorine can be found in the channel region. We show that both hydrogen and fluorine reduced oxygen vacancies and that fluorine stabilized weak oxygen and hydroxide bonds. These results demonstrate the large potential of photosensitive hybrid passivation layers as effective passivation materials.

  13. Inter-observer variation of diagnosis of Alzheimer's disease by SPECT

    International Nuclear Information System (INIS)

    Oshima, Motoo; Machida, Kikuo; Koizumi, Kiyoshi

    2001-01-01

    SPECT shows characteristic distribution in Alzheimer's disease. The purpose of this study is to define inter-observer variations in the diagnosis of Alzheimer's disease. Fifty-seven patients, included 19 Alzheimer's disease were collected from four institutions. Five-graded score was used to interprete SPECT in 18 regions. Ten nuclear medicine physicians interpreted SPECT referred with MMSE and clinical information. Among 57 cases 19 Alzheimer's disease were selected in this study. Statistics were performed between SPECT score and MMSE score. In conclusion, inter-observer variation is present in SPECT interpretation. There was a good correlation SPECT and MMSE with proper brain SPECT physicians. They are superior to in the interpretation not only resident, but other specialists. Education in the interpretation of brain SPECT looks important. (author)

  14. EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision

    International Nuclear Information System (INIS)

    Verberne, Hein J.; Eck-Smit, Berthe L.F. van; Wit, Tim C. de; Acampa, Wanda; Anagnostopoulos, Constantinos; Ballinger, Jim; Bengel, Frank; Bondt, Pieter De; Buechel, Ronny R.; Kaufmann, Philip A.; Cuocolo, Alberto; Flotats, Albert; Hacker, Marcus; Hindorf, Cecilia; Lindner, Oliver; Ljungberg, Michael; Lonsdale, Markus; Manrique, Alain; Minarik, David; Scholte, Arthur J.H.A.; Slart, Riemer H.J.A.; Traegaardh, Elin; Hesse, Birger

    2015-01-01

    Since the publication of the European Association of Nuclear Medicine (EANM) procedural guidelines for radionuclide myocardial perfusion imaging (MPI) in 2005, many small and some larger steps of progress have been made, improving MPI procedures. In this paper, the major changes from the updated 2015 procedural guidelines are highlighted, focusing on the important changes related to new instrumentation with improved image information and the possibility to reduce radiation exposure, which is further discussed in relation to the recent developments of new International Commission on Radiological Protection (ICRP) models. Introduction of the selective coronary vasodilator regadenoson and the use of coronary CT-contrast agents for hybrid imaging with SPECT/CT angiography are other important areas for nuclear cardiology that were not included in the previous guidelines. A large number of minor changes have been described in more detail in the fully revised version available at the EANM home page: http://eanm.org/ publications/guidelines/2015 0 7 E ANM F INAL myocardial p erfusion g uideline.pdf. (orig.)

  15. Gallium-67 activated charcoal: a new method for preparation of radioactive capsules for colonic transit study

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Kai-Yuan [Department of Radiological Technology, ChungTai Institute of Health Sciences and Technology, Taichung (Taiwan); Tsai, Shih-Chuan [Department of Nuclear Medicine, Show Chwan Memorial Hospital, Changhua (Taiwan); Lin, Wan-Yu. [Department of Nuclear Medicine, Taichung Veterans General Hospital, 160 Taichung Harbor Road, Section 3, 40705, Taichung (Taiwan)

    2003-06-01

    Indium-111 is currently the radionuclide of choice for colonic transit study. However, it is expensive and not available in many hospitals. Technetium-99m has been proposed for colonic transit study but the short half-life has limited its use. Gallium-67 citrate is inexpensive and available in most countries. Most importantly, it has a suitable half-life for colonic transit study. Attempts have been made in some studies to use {sup 67}Ga citrate to label activated charcoal, but the results have not been good because of poor stability. In this study, we successfully labelled activated charcoal with {sup 67}Ga citrate by adding alcohol and 5% glucose solution. To evaluate the in vitro stability, the {sup 67}Ga-activated charcoal was incubated in a milieu mimicking the intestinal content, containing lipase, trypsin and glycochenodeoxycholate at different pH values (6.0, 7.0, 7.4 and 8.0) and for different durations (0 h, 24 h, 48 h, 72 h and 96 h). For the in vivo study, the {sup 67}Ga-activated charcoal was loaded into a commercial empty enteric capsule. Colonic transit scintigraphy was performed in five volunteers, including three healthy people and two constipated patients, after intake of the radioactive capsule. Images were obtained at 2 h, 4 h, 6 h, 8 h, 24h, 48 h, 72 h etc. until no radioactivity was detected in the bowel. Our data show that the in vitro stability of {sup 67}Ga-activated charcoal was good. The labelling efficiency still exceeded 91% at 96 h at pH values of 6.0, 7.0 and 7.4. In the group with a pH value of 8.0, the labelling efficiency gradually fell during the 4-day incubation but was still higher than 88% at the end of the fourth day. In the in vivo study, most capsules disintegrated in the caecum/colon region, and the {sup 67}Ga-activated charcoal mixed very well with bowel content. In addition, the radioactive charcoal could be detected clearly on the 72-h image, which is very important for the evaluation of colonic transit time in patients

  16. Brain SPECT in psychiatry: Delusion or reality?

    International Nuclear Information System (INIS)

    Pavel, D.G.; Davis, G.; Epstein, P.; Kohn, R.; Antonino, F.; Devore-Best, S.; Craita, I.; Liu, P.

    2002-01-01

    Aim: The need for functional information is becoming increasingly evident for proper therapeutic approaches to the treatment and follow up of psychiatric diseases. While data on this subject already exists, there is a general lack of consensus about the use of brain SPECT in this domain and also a considerable negative prejudice due to a number of factors including poor quality imaging and unrealistic expectations. Based on a large group of brain SPECT-s performed over the past 3 years we attempted to sort and refine the indications for SPECT in psychiatry. Materials and Methods: High resolution brain SPECT was performed with triple head gamma camera, super-high resolution fan beam collimator and Tc-HMPAO. A comprehensive semiquantitative color, 3D surface as well as multi-thresholded volume display was routinely used and supplemented by automatic realignment in case of longitudinal follow-up. Results: 470 brain SPECT-s done on 432 patients were all referred by psychiatrists or neuro-psychiatrists for a wide spectrum of psychiatric diseases and ranged in age from 7 to 88 years. The most common primary reasons for referral were : attention deficit hyperactive disorder (ADHD); anxiety; obsessive-compulsive disease, depression (refractory, chronic, bipolar ), impulse control problems; oppositional defiance, post traumatic brain injury; seizures, learning difficulties, pervasive development disorders, memory loss and differential of dementia. Among common denominators were long duration of the disease, unresponsiveness to treatment, worsening of clinical status, and presence of multiple conditions at the same time. The multiparametric display used enabled a comprehensive evaluation of the brain volume which included the hemispheric surfaces; the basal ganglia (striatum) and the thalamus, several components of the limbic and paralimbic systems: anterior and posterior cingulate and their respective subdivisions, insula-s and their subdivisions, apical and mesial

  17. Evaluation of usefulness of bone SPECT for lumbar spondylolysis

    International Nuclear Information System (INIS)

    Watanabe, Osamu; Hashimoto, Manabu; Tomura, Noriaki; Watarai, Jiro

    2002-01-01

    The purpose of this study was to evaluate the usefulness of 99m Tc-MDP SPECT (bone SPECT) for lumbar spondylolysis. We analyzed 11 cases with 17 lesions. All cases were compared using plain radiography, computed tomography (CT), planar bone scintigraphy (PBS), and bone SPECT. Four lesions that showed a wide defect on CT were negative on bone SPECT and may have been chronic lesions. Thirteen lesions that were positive on bone SPECT were narrow or showed no defect on CT and may have been early lesions. Two cases showed no defect on CT but were positive on bone SPECT, and one of them progressed to bilateral spondylolysis after one year. This may have been a very early lesion. Thus bone SPECT is useful for the diagnosis of lumbar spondylolysis, especially in its early stage. (author)

  18. Evaluation of usefulness of bone SPECT for lumbar spondylolysis

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Osamu; Hashimoto, Manabu; Tomura, Noriaki; Watarai, Jiro [Akita Univ. (Japan). School of Medicine

    2002-07-01

    The purpose of this study was to evaluate the usefulness of {sup 99m}Tc-MDP SPECT (bone SPECT) for lumbar spondylolysis. We analyzed 11 cases with 17 lesions. All cases were compared using plain radiography, computed tomography (CT), planar bone scintigraphy (PBS), and bone SPECT. Four lesions that showed a wide defect on CT were negative on bone SPECT and may have been chronic lesions. Thirteen lesions that were positive on bone SPECT were narrow or showed no defect on CT and may have been early lesions. Two cases showed no defect on CT but were positive on bone SPECT, and one of them progressed to bilateral spondylolysis after one year. This may have been a very early lesion. Thus bone SPECT is useful for the diagnosis of lumbar spondylolysis, especially in its early stage. (author)

  19. Morphological Performance of Onion under Exogenous Treatments of GA3

    Directory of Open Access Journals (Sweden)

    Md.Dulal SARKAR

    2018-03-01

    Full Text Available The present study was conducted to assess the morphological response of onion plants to different GA3 levels (0, 20, 40 and 60 ppm. The factor levels of GA3 were applied during transplanting by root soaking and foliar spray at 30 and 60 days after transplanting. The gibberellic acid had a great effect on increasing plant height (46.50 cm, shoot biomass (641.67 g m-2, bulb biomass (1125.00 g m-2 and also dry matter accumulation in onion plants under the effect of 60 ppm compared to control. Plants grown up without GA3 application were shorter than those grown with GA3 spray where the lowest plant height (34.67 cm was remarked. The leaf number (11.43 was considerably increased when 60 ppm GA3 was used as the growth promoter factor in comparison to control. The plants attain minimum fresh biomass at harvesting time in the shoot (441.67 g m-2 and bulb (641.67 g m-2 grown in control plot. Considerably (41.63% more dry shoot biomass accumulation was recorded in 60 ppm GA3 treated plants in comparison with the control at harvesting stages. Insignificant effect by all concentration of GA3 was found in bulb length, fresh root biomass and dry root biomass. Thus, the use of 60 ppm GA3 can be recommend for onion production due to the significantly increased of the fresh bulb biomass with about 42.96% over control.

  20. SPECT assay of radiolabeled monoclonal antibodies

    International Nuclear Information System (INIS)

    Jaszczak, R.J.

    1992-02-01

    The long-term goal of this research project is to develop methods to improve the utility of single photon emission computed tomography (SPECI) to quantify the biodistribution of monoclonal antibodies (MoAbs) labeled with clinically relevant radionuclides ( 123 I, 131 I, and 111 In) and with another radionuclide, 211 At, recently used in therapy. We describe here our progress in developing quantitative SPECT methodology for 111 In and 123 I. We have focused our recent research thrusts on the following aspects of SPECT: (1) The development of improved SPECT hardware, such as improved acquisition geometries. (2) The development of better reconstruction methods that provide accurate compensation for the physical factors that affect SPECT quantification. (3) The application of carefully designed simulations and experiments to validate our hardware and software approaches

  1. Importance of SPECT/CT for knee and hip joint prostheses; Stellenwert der SPECT/CT bei Knie- und Hueftgelenkprothesen

    Energy Technology Data Exchange (ETDEWEB)

    Strobel, K.; Steurer-Dober, I.; Huellner, M.W.; Veit-Haibach, P.; Allgayer, B. [Luzerner Kantonsspital (Switzerland). Institut fuer Nuklearmedizin und Roentgendiagnostik

    2012-07-15

    Complications, such as loosening or infections are common problems after hip or knee arthroplasty. If conventional X-rays are equivocal bone scintigraphy is the classical second-line imaging modality. Single photon emission computed tomography/computed tomography (SPECT/CT) offers metabolic and morphologic information in one imaging step and is becoming increasingly more available in larger hospitals. The SPECT/CT procedure is a promising method and is increasingly being used in daily routine to evaluate joint arthroplasty. The additional benefit compared with classical conventional bone scintigraphy has to be evaluated in further prospective studies. In our hospital SPECT/CT regularly gives important additional information regarding prosthetic joint complications. SPECT/CT is increasingly being used as the second step imaging standard modality if conventional X-rays are equivocal. (orig.) [German] Komplikationen wie Lockerung und Infekt stellen ein haeufiges Problem nach Hueft- und Kniegelenkprothesen dar. Wenn die konventionelle Roentgenaufnahme nicht zum Ziel fuehrt, ist die klassische konventionelle Skelettszintigraphie die am haeufigsten verwendete ''Second-line''-Bildgebung. Die ''single photon emission computed tomography''/CT (SPECT/CT) bietet metabolische und morphologische Informationen bzgl. Prothesenkomplikationen in einem Untersuchungsgang und ist zunehmend in groesseren Kliniken verfuegbar. Die SPECT/CT ist eine viel versprechende Methode und wird im klinischen Alltag bei der Evaluation von Gelenkprothesen zunehmend eingesetzt. Es sind noch mehr prospektive Studien noetig, um die Leistungsfaehigkeit und den Zusatznutzen gegenueber der klassischen Szintigraphie zu evaluieren. In unserer Klinik wird die Knochenszintigraphie bei der Abklaerung von Prothesenkomplikationen zumeist mit einer SPECT/CT kombiniert und liefert regelmaessig wichtige Zusatzinformationen. Die SPECT/CT entwickelt sich zunehmend zum Standard

  2. Fast and simple one-step preparation of Ga-68 citrate for routine clinical PET

    DEFF Research Database (Denmark)

    Jensen, Svend B.; Nielsen, Karin M.; Mewis, Dennis

    2013-01-01

    The imaging of infectious and inflammatory diseases using gallium-67 (Ga-67) citrate scintigraphy has been a well-established diagnostic tool for decades. In recent times, interest has focused on PET using the short-lived positron emitting radioisotope Ga-68. Ga-68 is not only more readily...

  3. Clinical value of SPECT/CT for evaluation of patients with painful knees after total knee arthroplasty- a new dimension of diagnostics?

    Directory of Open Access Journals (Sweden)

    Rasch Helmut

    2011-02-01

    Full Text Available Abstract Background The purpose of our study was to evaluate the clinical value of hybrid SPECT/CT for the assessment of patients with painful total knee arthroplasty (TKA. Methods Twenty-three painful knees in patients following primary TKA were assessed using Tc-99m-HDP-SPECT/CT. Rotational, sagittal and coronal position of the TKA was assessed on 3D-CT reconstructions. The level of the SPECT-tracer uptake (0-10 and its anatomical distribution was mapped using a validated localization scheme. Univariate analysis (Wilcoxon-Mann-Whitney, Spearmean`s-rho test, p Results SPECT/CT imaging changed the suspected diagnosis and the proposed treatment in 19/23 (83% knees. Progression of patellofemoral OA (n = 11, loosening of the tibial (n = 3 and loosening of the femoral component (n = 2 were identified as the leading causes of pain after TKA. Patients with externally rotated tibial trays showed higher tracer uptake in the medial patellar facet (p = 0.049 and in the femur (p = 0.051. Patients with knee pain due to patellofemoral OA showed significantly higher tracer uptake in the patella than others (p Conclusions SPECT/CT was very helpful in establishing the diagnosis and guiding subsequent management in patients with painful knees after TKA, particularly in patients with patellofemoral problems and malpositioned or loose TKA.

  4. Yields of nuclear reactions for the production of radiopharmaceuticals 18F, 43K, 67Ga, 111In and 123I with charged particles

    International Nuclear Information System (INIS)

    Bem, P.; Burjan, V.; Schaferlingova, W.; Vincour, J.; Kopecky, P.

    1977-02-01

    Experimental results are given of reaction yields in the preparation of radiopharmaceuticals ( 18 F, 43 K, 67 Ga, 111 In, 123 I) using common cyclotron beams, i.e., proton beams, deuteron beams, 3 He and alpha particles in an energy range of up to several MeV/nucleon. A detailed analysis is made of the choice of suitable target materials for the production of the above radiopharmaceuticals with regard to the economical use of the accelerator and of the purity of the radiopharmaceuticals prepared. (I.W.)

  5. Scheduling Appliances with GA, TLBO, FA, OSR and Their Hybrids Using Chance Constrained Optimization for Smart Homes

    Directory of Open Access Journals (Sweden)

    Zunaira Nadeem

    2018-04-01

    Full Text Available In this paper, we design a controller for home energy management based on following meta-heuristic algorithms: teaching learning-based optimization (TLBO, genetic algorithm (GA, firefly algorithm (FA and optimal stopping rule (OSR theory. The principal goal of designing this controller is to reduce the energy consumption of residential sectors while reducing consumer’s electricity bill and maximizing user comfort. Additionally, we propose three hybrid schemes OSR-GA, OSR-TLBO and OSR-FA, by combining the best features of existing algorithms. We have also optimized the desired parameters: peak to average ratio, energy consumption, cost, and user comfort (appliance waiting time for 20, 50, 100 and 200 heterogeneous homes in two steps. In the first step, we obtain the optimal scheduling of home appliances implementing our aforementioned hybrid schemes for single and multiple homes while considering user preferences and threshold base policy. In the second step, we formulate our problem through chance constrained optimization. Simulation results show that proposed hybrid scheduling schemes outperformed for single and multiple homes and they shift the consumer load demand exceeding a predefined threshold to the hours where the electricity price is low thus following the threshold base policy. This helps to reduce electricity cost while considering the comfort of a user by minimizing delay and peak to average ratio. In addition, chance-constrained optimization is used to ensure the scheduling of appliances while considering the uncertainties of a load hence smoothing the load curtailment. The major focus is to keep the appliances power consumption within the power constraint, while keeping power consumption below a pre-defined acceptable level. Moreover, the feasible regions of appliances electricity consumption are calculated which show the relationship between cost and energy consumption and cost and waiting time.

  6. Brain imaging during seizure: ictal brain SPECT

    International Nuclear Information System (INIS)

    Kottamasu, Sambasiva Rao

    1997-01-01

    The role of single photon computed tomography (SPECT) in presurgical localization of medically intractable complex partial epilepsy (CPE) in children is reviewed. 99m Technetium neurolite, a newer lipophylic agent with a high first pass brain extraction and little or no redistribution is injected during a seizure, while the child is monitored with a video recording and continuous EEG and SPECT imaging is performed in the next 1-3 hours with the images representing regional cerebral profusion at the time of injection. On SPECT studies performed with radiopharmaceutical injected during a seizure, ictal focus is generally hypervascular. Other findings on ictal brain SPECT include hypoperfusion of adjacent cerebral cortex and white matter, hyperperfusion of contralateral motor cortex, hyperperfusion of ipsilateral basal ganglia and thalamus, brain stem and contralateral cerebellum. Ictal brain SPECT is non-invasive, cost effective and highly sensitive for localization of epileptic focus in patients with intractable CPE. (author)

  7. High-resolution SPECT for small-animal imaging

    International Nuclear Information System (INIS)

    Qi Yujin

    2006-01-01

    This article presents a brief overview of the development of high-resolution SPECT for small-animal imaging. A pinhole collimator has been used for high-resolution animal SPECT to provide better spatial resolution and detection efficiency in comparison with a parallel-hole collimator. The theory of imaging characteristics of the pinhole collimator is presented and the designs of the pinhole aperture are discussed. The detector technologies used for the development of small-animal SPECT and the recent advances are presented. The evolving trend of small-animal SPECT is toward a multi-pinhole and a multi-detector system to obtain a high resolution and also a high detection efficiency. (authors)

  8. SPECT/CT Fusion in the Diagnosis of Hyperparathyroidism

    International Nuclear Information System (INIS)

    Monzen, Yoshio; Tamura, Akihisa; Okazaki, Hajime; Kurose, Taichi; Kobayashi, Masayuki; Kuraoka, Masatsugu

    2015-01-01

    In this study, we aimed to analyze the relationship between the diagnostic ability of fused single photon emission computed tomography/ computed tomography (SPECT/CT) images in localization of parathyroid lesions and the size of adenomas or hyperplastic glands. Five patients with primary hyperparathyroidism (PHPT) and 4 patients with secondary hyperparathyroidism (SHPT) were imaged 15 and 120 minutes after the intravenous injection of technetium99m-methoxyisobutylisonitrile ( 99m Tc-MIBI). All patients underwent surgery and 5 parathyroid adenomas and 10 hyperplastic glands were detected. Pathologic findings were correlated with imaging results. The SPECT/CT fusion images were able to detect all parathyroid adenomas even with the greatest axial diameter of 0.6 cm. Planar scintigraphy and SPECT imaging could not detect parathyroid adenomas with an axial diameter of 1.0 to 1.2 cm. Four out of 10 (40%) hyperplastic parathyroid glands were diagnosed, using planar and SPECT imaging and 5 out of 10 (50%) hyperplastic parathyroid glands were localized, using SPECT/CT fusion images. SPECT/CT fusion imaging is a more useful tool for localization of parathyroid lesions, particularly parathyroid adenomas, in comparison with planar and or SPECT imaging

  9. [{sup 123}]FP-CIT SPECT scans initially rated as normal became abnormal over time in patients with probable dementia with Lewy bodies

    Energy Technology Data Exchange (ETDEWEB)

    Zande, J.J. van der; Scheltens, P.; Lemstra, A.W. [VU Medical Center Alzheimer Center, Amsterdam (Netherlands); Booij, J. [Academic Medical Center, Department of Nuclear Medicine, Amsterdam (Netherlands); Raijmakers, P.G.H.M. [VU Medical Center, Department of Nuclear Medicine, Amsterdam (Netherlands)

    2016-06-15

    Decreased striatal dopamine transporter (DAT) binding on SPECT imaging is a strong biomarker for the diagnosis of dementia with Lewy bodies (DLB). There is still a lot of uncertainty about patients meeting the clinical criteria for probable DLB who have a normal DAT SPECT scan (DLB/S-). The aim of this study was to describe the clinical and imaging follow-up in these patients, and compare them to DLB patients with abnormal baseline scans (DLB/S+). DLB patients who underwent DAT imaging ([{sup 123}I]FP-CIT SPECT) were selected from the Amsterdam Dementia Cohort. All [{sup 123}I]FP-CIT SPECT scans were evaluated independently by two nuclear medicine physicians and in patients with normal scans follow-up imaging was obtained. We matched DLB/S- patients for age and disease duration to DLB/S+ patients and compared their clinical characteristics. Of 67 [{sup 123}I]FP-CIT SPECT scans, 7 (10.4 %) were rated as normal. In five DLB/S- patients, a second [{sup 123}I]FP-CIT SPECT was performed (after on average 1.5 years) and these scans were all abnormal. No significant differences in clinical characteristics were found at baseline. DLB/S- patients could be expected to have a better MMSE score after 1 year. This study was the first to investigate DLB patients with the initial [{sup 123}I]FP-CIT SPECT scan rated as normal and subsequent scans during disease progression rated as abnormal. We hypothesize that DLB/S- scans could represent a relatively rare DLB subtype with possibly a different severity or spread of alpha-synuclein pathology (''neocortical predominant subtype''). In clinical practice, if an alternative diagnosis is not imminent in a DLB/S- patient, repeating [{sup 123}I]FP-CIT SPECT should be considered. (orig.)

  10. Attenuation correction of myocardial SPECT images with X-ray CT. Effects of registration errors between X-ray CT and SPECT

    International Nuclear Information System (INIS)

    Takahashi, Yasuyuki; Murase, Kenya; Mochizuki, Teruhito; Motomura, Nobutoku

    2002-01-01

    Attenuation correction with an X-ray CT image is a new method to correct attenuation on SPECT imaging, but the effect of the registration errors between CT and SPECT images is unclear. In this study, we investigated the effects of the registration errors on myocardial SPECT, analyzing data from a phantom and a human volunteer. Registerion (fusion) of the X-ray CT and SPECT images was done with standard packaged software in three dimensional fashion, by using linked transaxial, coronal and sagittal images. In the phantom study, and X-ray CT image was shifted 1 to 3 pixels on the x, y and z axes, and rotated 6 degrees clockwise. Attenuation correction maps generated from each misaligned X-ray CT image were used to reconstruct misaligned SPECT images of the phantom filled with 201 Tl. In a human volunteer, X-ray CT was acquired in different conditions (during inspiration vs. expiration). CT values were transferred to an attenuation constant by using straight lines; an attenuation constant of 0/cm in the air (CT value=-1,000 HU) and that of 0.150/cm in water (CT value=0 HU). For comparison, attenuation correction with transmission CT (TCT) data and an external γ-ray source ( 99m Tc) was also applied to reconstruct SPECT images. Simulated breast attenuation with a breast attachment, and inferior wall attenuation were properly corrected by means of the attenuation correction map generated from X-ray CT. As pixel shift increased, deviation of the SPECT images increased in misaligned images in the phantom study. In the human study, SPECT images were affected by the scan conditions of the X-ray CT. Attenuation correction of myocardial SPECT with an X-ray CT image is a simple and potentially beneficial method for clinical use, but accurate registration of the X-ray CT to SPECT image is essential for satisfactory attenuation correction. (author)

  11. 67Ga(NODASA): a new potential bifunctional radioligand for coupling to peptides

    International Nuclear Information System (INIS)

    Andre, J.P.; Maecke, H.R.; Zehnder, M.; Macko, L.; Kaspar, A.

    1998-01-01

    A new bifunctional chelator NODASA (1,4,7-triazacyclononane-1-succinic acid-4,7-diacetic acid) has been synthesised and its Ga(III) complex was crystallographically characterized by X-ray diffraction. The complex showed to be stable in serum and in acidic conditions and its stability constant was determined using a competition method with an auxiliary ligand. The conjugation of Ga(NODASA) to a model aminoacidamide proved the feasibility of a prelabelling approach. (author)

  12. PET and SPECT in psychiatry

    International Nuclear Information System (INIS)

    Dierckx, Rudi A.J.O.; Otte, Andreas; Vries, Erik F.J. de; Waarde, Aren van

    2014-01-01

    Covers classical psychiatric disorders as well as other subjects such as suicide, sleep, eating disorders, and autism. Emphasis on a multidisciplinary approach. Written by internationally acclaimed experts. PET and SPECT in Psychiatry showcases the combined expertise of renowned authors whose dedication to the investigation of psychiatric disease through nuclear medicine technology has achieved international recognition. The classical psychiatric disorders as well as other subjects - such as suicide, sleep, eating disorders, and autism - are discussed and the latest results in functional neuroimaging are detailed. Most chapters are written jointly by a clinical psychiatrist and a nuclear medicine expert to ensure a multidisciplinary approach. This state of the art compendium will be valuable to all who have an interest in the field of neuroscience, from the psychiatrist and the radiologist/nuclear medicine specialist to the interested general practitioner and cognitive psychologist. It is the first volume of a trilogy on PET and SPECT imaging in the neurosciences; other volumes will focus on PET and SPECT in neurology and PET and SPECT of neurobiological systems.

  13. PET and SPECT in psychiatry

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, Rudi A.J.O. [University Medical Center Groningen (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Ghent Univ. (Belgium); Otte, Andreas [Univ. of Applied Sciences Offenburg (Germany). Faculty of Electrical Engineering and Information Technology; Vries, Erik F.J. de; Waarde, Aren van (eds.) [University Medical Center Groningen (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging

    2014-09-01

    Covers classical psychiatric disorders as well as other subjects such as suicide, sleep, eating disorders, and autism. Emphasis on a multidisciplinary approach. Written by internationally acclaimed experts. PET and SPECT in Psychiatry showcases the combined expertise of renowned authors whose dedication to the investigation of psychiatric disease through nuclear medicine technology has achieved international recognition. The classical psychiatric disorders as well as other subjects - such as suicide, sleep, eating disorders, and autism - are discussed and the latest results in functional neuroimaging are detailed. Most chapters are written jointly by a clinical psychiatrist and a nuclear medicine expert to ensure a multidisciplinary approach. This state of the art compendium will be valuable to all who have an interest in the field of neuroscience, from the psychiatrist and the radiologist/nuclear medicine specialist to the interested general practitioner and cognitive psychologist. It is the first volume of a trilogy on PET and SPECT imaging in the neurosciences; other volumes will focus on PET and SPECT in neurology and PET and SPECT of neurobiological systems.

  14. Contralateral thalamic hypoperfusion on brain perfusion SPECT

    International Nuclear Information System (INIS)

    Lee, Seok Mo; Bae, Sang Kyun; Yoo, Kyung Moo; Yum, Ha Yong

    2000-01-01

    Brain perfusion single photon emission computed tomography (SPECT) is useful for the localization of cerebrovascular lesion and sometimes reveals more definite lesion than radiologic imaging modality such as CT or MRI does. The purpose of this study was to evaluate the diagnostic usefulness of brain perfusion SPECT in patients with hemisensory impairment. Thirteen consecutive patients (M:F= 8:5, mean age = 48) who has hemisensory impairment were included. Brain perfusion SPECT was performed after intravenous injection of 1110 MBq of Tc-99m ECD. The images were obtained using a dual-head gamma camera with ultra-high resolution collimator. Semiquantitative analysis was performed after placing multiple ROIs on cerebral cortex, basal ganglia, thalamus and cerebellum. There were 10 patients with left hemisensory impairment and 3 patients with right-sided symptom. Only 2 patients revealed abnormal signal change in the thalamus on MRI. But brain perfusion SPECT showed decreased perfusion in the thalamus in 9 patients. Six patients among 10 patients with left hemisensory impairment revealed decreased perfusion in the contralateral thalamus on brain SPECT. The other 4 patients revealed no abnormality. Two patients among 3 patients with right hemisensory impairment also showed decreased perfusion in the contralateral thalamus on brain SPECT. One patients with right hemisensory impairment showed ipsilateral perfusion decrease. Two patients who had follow-up brain perfusion SEPCT after treatment revealed normalization of perfusion in the thalamus. Brain perfusion SPECT might be a useful tool in diagnosing patients with hemisensory impairment

  15. Use of 99mTc-sestamibi Single-photon Emission Computed Tomography / X-ray Computed Tomography in the Diagnosis of Hybrid Oncocytic / Chromophobe Tumor in a Pediatric Patient.

    Science.gov (United States)

    Almassi, Nima; Gorin, Michael A; Purysko, Andrei S; Rowe, Steven P; Kaouk, Jihad; Allaf, Mohamad E; Campbell, Steven C; Rhee, Audrey

    2018-03-01

    The differential diagnosis of solid renal neoplasms in adolescence includes aggressive malignancy and indolent oncocytic tumors, which are typically indistinguishable using conventional imaging. We report the use of 99m Tc-sestamibi single-photon emission computed tomography / x-ray computed tomography (SPECT/CT) in characterizing enhancing renal neoplasms in a pediatric patient. Genetic testing suggested a hereditary syndrome associated with aggressive malignancy, whereas renal mass biopsy suggested an oncocytic tumor. 99m Tc-sestamibi SPECT/CT indicated probable oncocytomas or hybrid oncocytic / chomophobe tumors. Enucleative resection was performed with final pathology demonstrating hybrid oncocytic / chomophobe tumors. This case highlights the potential utility of 99m Tc-sestamibi SPECT/CT in characterizing indeterminate enhancing renal neoplasm in pediatric patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Molecular identification of hybrids from a former hot spot of Potamogeton hybrid diversity

    Czech Academy of Sciences Publication Activity Database

    Kaplan, Zdeněk; Fehrer, Judith

    2013-01-01

    Roč. 105, Feb 2013 (2013), s. 34-40 ISSN 0304-3770 R&D Projects: GA ČR GA206/09/0291 Institutional support: RVO:67985939 Keywords : hybridization * taxonomy * diversity Subject RIV: EF - Botanics Impact factor: 1.471, year: 2013

  17. Studies on the radiochemical separation of Ga(III) from Zn(II)

    International Nuclear Information System (INIS)

    Chirayil, Viju; Vimalnath, K.V.; Jagadeesan, K.C.; Thakare, S.V.; Dhami, P.S.; Jagesia, Poonam; Dakshinamoorthy, A.

    2007-01-01

    The 67 Ga, produced in cyclotron from zinc target is widely used in tumor imaging in the form of gallium citrate. A method to separate gallium from zinc is developed using cation exchange chromatography. Reactor produced 65 Zn and 72 Ga were used to study the separation characteristics for further applicability in cyclotron production of 67 Ga. Zinc forms a stable cationic complex with NH 3 , whereas, Gallium forms anionic gallate (Ga(OH) 4 )- at pH 9.3. Zinc is quantitatively taken up by the cation exchange resin (Tulsion T-42) in NH 4 + form, thus effecting a simple rapid one step separation between Zn and Ga. (author)

  18. Avaliação de foco epileptogênico do lobo temporal: correlação entre SPECT ictal, ressonância magnética e ressonância magnética com espectroscopia de prótons Evaluation of epileptogenic focus in temporal lobe: correlation between ictal brain SPECT, magnetic resonance imaging and magnetic resonance spectroscopy

    Directory of Open Access Journals (Sweden)

    Maria Elena Martins Diegues

    2004-02-01

    Full Text Available O objetivo deste trabalho foi determinar a existência de concordância entre os métodos radioisotópico e radiológico e, em caso positivo, avaliar a utilidade do SPECT ictal na determinação do foco epileptogênico. Foram realizados SPECT ictal, ressonância magnética (RM e ressonância magnética com espectroscopia de prótons (RME em seis pacientes com epilepsia de lobo temporal refratária. O SPECT ictal foi realizado após a retirada das drogas antiepilépticas durante monitoramento por vídeo-EEG, utilizando-se o 99mTc-ECD, administrado aos pacientes no início da crise. As imagens de RM foram obtidas em T1, T2 e FLAIR, com cortes de 3 e 5 mm de espessura, e a RME foi realizada com técnica PRESS, com voxel único posicionado no hipocampo, bilateralmente. A análise estatística incluiu os valores de Kappa (k, erro-padrão (ep e o nível de significância (p para a lateralização do foco. Os achados foram analisados com base na localização por EEG da descarga ictal, no tempo de duração da crise (109-280 s; média: 152 s e no tempo de administração do traçador (30-262 s; média: 96 s. Obtivemos dados correlatos em quatro pacientes (67%, com valores de k = 0,67, ep = 0,38 e p = 0,041. Concluímos que existe concordância entre SPECT ictal, RM e RME, e a utilidade do procedimento radioisotópico está relacionada aos casos em que o EEG não é diagnóstico e quando há discordância ou indefinição diagnóstica na análise comparativa entre EEG, RM e RME.The purpose of this study was to determine the degree of concordance between radiological and radioisotopic methods and, if positive, to evaluate the usefulness of ictal SPECT in the localization of the epileptogenic focus. Ictal brain SPECT, magnetic resonance imaging (MRI and magnetic resonance spectroscopy (MRS were performed on six patients with refractory temporal lobe epilepsy. Ictal SPECT was performed after withdrawal of the anti-epileptogenic drugs during video

  19. MR guided spatial normalization of SPECT scans

    International Nuclear Information System (INIS)

    Crouch, B.; Barnden, L.R.; Kwiatek, R.

    2010-01-01

    Full text: In SPECT population studies where magnetic resonance (MR) scans are also available, the higher resolution of the MR scans allows for an improved spatial normalization of the SPECT scans. In this approach, the SPECT images are first coregistered to their corresponding MR images by a linear (affine) transformation which is calculated using SPM's mutual information maximization algorithm. Non-linear spatial normalization maps are then computed either directly from the MR scans using SPM's built in spatial normalization algorithm, or, from segmented TI MR images using DARTEL, an advanced diffeomorphism based spatial normalization algorithm. We compare these MR based methods to standard SPECT based spatial normalization for a population of 27 fibromyalgia patients and 25 healthy controls with spin echo T 1 scans. We identify significant perfusion deficits in prefrontal white matter in FM patients, with the DARTEL based spatial normalization procedure yielding stronger statistics than the standard SPECT based spatial normalization. (author)

  20. Skeletal scintigraphy and SPECT/CT in orthopedic imaging; Knochenszintigrafie und SPECT/CT bei orthopaedischen Fragestellungen

    Energy Technology Data Exchange (ETDEWEB)

    Klaeser, B.; Walter, M.; Krause, T. [Inselspital Bern (Switzerland). Universitaetsklinik fuer Nuklearmedizin

    2011-03-15

    Multi-modality imaging with SPECT-CT in orthopaedics combines the excellent sensitivity of scintigraphy with the morphological information of CT as a key for specific interpretation of findings in bone scans. The result is an imaging modality with the clear potential to prove of value even in a competitive setting dominated by MRI, and to significantly add to diagnostic imaging in orthopaedics. SPECT-CT is of great value in the diagnostic evaluation after fractures, and - in contrast to MRI - it is well suited for imaging in patients with osteosyntheses and metallic implants. In sports medicine, SPECT-CT allows for a sensitive and specific detection of osseous stress reactions before morphological changes become detectable by CT or MRI. In patients with osseous pain syndromes, actively evolving degenerative changes as a cause of pain can be identified and accurately localized. Further, particularly prospective diagnostic studies providing comparative data are needed to strengthen the position of nuclear imaging in orthopaedics and sports medicine and to help implementing SPECT/CT in diagnostic algorithms. (orig.)

  1. Integrated SPECT/CT for assessment of haemodynamically significant coronary artery lesions in patients with acute coronary syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Rispler, Shmuel [Technion - Israel Institute of Technology, Department of Cardiology, Rambam Health Care Campus and the B. Rappaport Faculty of Medicine, Haifa (Israel); Technion - Israel Institute of Technology, Department of Nuclear Medicine, Rambam Health Care Campus and the B. Rappaport Faculty of Medicine, Haifa (Israel); Aronson, Doron; Roguin, Ariel; Beyar, Rafael [Technion - Israel Institute of Technology, Department of Cardiology, Rambam Health Care Campus and the B. Rappaport Faculty of Medicine, Haifa (Israel); Abadi, Sobhi; Engel, Ahuva [Technion - Israel Institute of Technology, Department of Medical Imaging, Rambam Health Care Campus and the B. Rappaport Faculty of Medicine, Haifa (Israel); Israel, Ora; Keidar, Zohar [Technion - Israel Institute of Technology, Department of Nuclear Medicine, Rambam Health Care Campus and the B. Rappaport Faculty of Medicine, Haifa (Israel)

    2011-10-15

    Early risk stratification in patients with non-ST elevation acute coronary syndromes (NSTE-ACS) is important since the benefit from more aggressive and costly treatment strategies is proportional to the risk of adverse clinical events. In the present study we assessed whether hybrid single photon emission computed tomography (SPECT)/coronary computed tomography angiography (CCTA) technology could be an appropriate tool in stratifying patients with NSTE-ACS. SPECT/CCTA was performed in 90 consecutive patients with NSTE-ACS. The Thrombolysis in Myocardial Infarction risk score (TIMI-RS) was used to classify patients as low- or high-risk. Imaging was performed using SPECT/CCTA to identify haemodynamically significant lesions defined as >50% stenosis on CCTA with a reversible perfusion defect on SPECT in the corresponding territory. CCTA demonstrated at least one lesion with >50% stenosis in 35 of 40 high-risk patients (87%) as compared to 14 of 50 low-risk patients (35%; TIMI-RS <3; p <0.0001). Of the 40 high-risk and 50 (16%) low-risk TIMI-RS patients, 16 (40%) and 8 (16%), respectively, had haemodynamically significant lesions (p = 0.01). Patients defined as high-risk by a high TIMI-RS, a positive CCTA scan or both (n = 45) resulted in a sensitivity of 95%, specificity of 49%, PPV of 35% and NPV of 97% for having haemodynamically significant coronary lesions. Those with normal perfusion were spared revascularization procedures, regardless of their TIMI-RS. Noninvasive assessment of coronary artery disease by SPECT/CCTA may play an important role in risk stratification of patients with NSTE-ACS by better identifying the subgroup requiring intervention. (orig.)

  2. Integrated SPECT/CT for assessment of haemodynamically significant coronary artery lesions in patients with acute coronary syndrome

    International Nuclear Information System (INIS)

    Rispler, Shmuel; Aronson, Doron; Roguin, Ariel; Beyar, Rafael; Abadi, Sobhi; Engel, Ahuva; Israel, Ora; Keidar, Zohar

    2011-01-01

    Early risk stratification in patients with non-ST elevation acute coronary syndromes (NSTE-ACS) is important since the benefit from more aggressive and costly treatment strategies is proportional to the risk of adverse clinical events. In the present study we assessed whether hybrid single photon emission computed tomography (SPECT)/coronary computed tomography angiography (CCTA) technology could be an appropriate tool in stratifying patients with NSTE-ACS. SPECT/CCTA was performed in 90 consecutive patients with NSTE-ACS. The Thrombolysis in Myocardial Infarction risk score (TIMI-RS) was used to classify patients as low- or high-risk. Imaging was performed using SPECT/CCTA to identify haemodynamically significant lesions defined as >50% stenosis on CCTA with a reversible perfusion defect on SPECT in the corresponding territory. CCTA demonstrated at least one lesion with >50% stenosis in 35 of 40 high-risk patients (87%) as compared to 14 of 50 low-risk patients (35%; TIMI-RS <3; p <0.0001). Of the 40 high-risk and 50 (16%) low-risk TIMI-RS patients, 16 (40%) and 8 (16%), respectively, had haemodynamically significant lesions (p = 0.01). Patients defined as high-risk by a high TIMI-RS, a positive CCTA scan or both (n = 45) resulted in a sensitivity of 95%, specificity of 49%, PPV of 35% and NPV of 97% for having haemodynamically significant coronary lesions. Those with normal perfusion were spared revascularization procedures, regardless of their TIMI-RS. Noninvasive assessment of coronary artery disease by SPECT/CCTA may play an important role in risk stratification of patients with NSTE-ACS by better identifying the subgroup requiring intervention. (orig.)

  3. Nuclear myocardial perfusion imaging using thallium-201 with a novel multifocal collimator SPECT/CT: IQ-SPECT versus conventional protocols in normal subjects.

    Science.gov (United States)

    Matsuo, Shinro; Nakajima, Kenichi; Onoguchi, Masahisa; Wakabayash, Hiroshi; Okuda, Koichi; Kinuya, Seigo

    2015-06-01

    A novel multifocal collimator, IQ-SPECT (Siemens) consists of SMARTZOOM, cardio-centric and 3D iterative SPECT reconstruction and makes it possible to perform MPI scans in a short time. The aims are to delineate the normal uptake in thallium-201 ((201)Tl) SPECT in each acquisition method and to compare the distribution between new and conventional protocol, especially in patients with normal imaging. Forty patients (eight women, mean age of 75 years) who underwent myocardial perfusion imaging were included in the study. All patients underwent one-day protocol perfusion scan after an adenosine-stress test and at rest after administering (201)Tl and showed normal results. Acquisition was performed on a Symbia T6 equipped with a conventional dual-headed gamma camera system (Siemens ECAM) and with a multifocal SMARTZOOM collimator. Imaging was performed with a conventional system followed by IQ-SPECT/computed tomography (CT). Reconstruction was performed with or without X-ray CT-derived attenuation correction (AC). Two nuclear physicians blinded to clinical information interpreted all myocardial perfusion images. A semi-quantitative myocardial perfusion was analyzed by a 17-segment model with a 5-point visual scoring. The uptake of each segment was measured and left ventricular functions were analyzed by QPS software. IQ-SPECT provided good or excellent image quality. The quality of IQ-SPECT images without AC was similar to those of conventional LEHR study. Mid-inferior defect score (0.3 ± 0.5) in the conventional LEHR study was increased significantly in IQ-SPECT with AC (0 ± 0). IQ-SPECT with AC improved the mid-inferior decreased perfusion shown in conventional images. The apical tracer count in IQ-SPECT with AC was decreased compared to that in LEHR (0.1 ± 0.3 vs. 0.5 ± 0.7, p IQ-SPECT was significantly higher than that from the LEHR collimator (p = 0.0009). The images of IQ-SPECT acquired in a short time are equivalent to that of conventional LEHR

  4. Further Charpy impact test results of low activation ferritic alloys, irradiated at 430 degrees C to 67 dpa

    International Nuclear Information System (INIS)

    Schubert, L.E.; Hamilton, M.L.; Gelles, D.S.

    1997-01-01

    Miniature CVN specimens of four ferritic alloys, GA3X, F82H, GA4X and HT9, have been impact tested following irradiation at 430 degrees C to 67 dpa. Comparison of the results with those of the previously tested lower dose irradiation condition indicates that the GA3X and F82H alloys, two primary candidate low activation alloys, exhibit virtually identical behavior following irradiation at 430 degrees C to ∼67 dpa and at 370 degrees C to ∼15 dpa. Very little shift is observed in either DBTT or USE relative to the unirradiated condition. The shifts in DBTT and USE observed in both GA4X and HT9 were smaller after irradiation at 430 degrees C to ∼67 dpa than after irradiation at 370 degrees C to ∼15 dpa

  5. Further Charpy impact test results of low activation ferritic alloys, irradiated at 430{degrees}C to 67 dpa

    Energy Technology Data Exchange (ETDEWEB)

    Schubert, L.E.; Hamilton, M.L.; Gelles, D.S. [Pacific Northwest National Lab., Richland, WA (United States)

    1997-04-01

    Miniature CVN specimens of four ferritic alloys, GA3X, F82H, GA4X and HT9, have been impact tested following irradiation at 430{degrees}C to 67 dpa. Comparison of the results with those of the previously tested lower dose irradiation condition indicates that the GA3X and F82H alloys, two primary candidate low activation alloys, exhibit virtually identical behavior following irradiation at 430{degrees}C to {approximately}67 dpa and at 370{degrees}C to {approximately}15 dpa. Very little shift is observed in either DBTT or USE relative to the unirradiated condition. The shifts in DBTT and USE observed in both GA4X and HT9 were smaller after irradiation at 430{degrees}C to {approximately}67 dpa than after irradiation at 370{degrees}C to {approximately}15 dpa.

  6. SPECT imaging with resolution recovery

    International Nuclear Information System (INIS)

    Bronnikov, A. V.

    2011-01-01

    Single-photon emission computed tomography (SPECT) is a method of choice for imaging spatial distributions of radioisotopes. Many applications of this method are found in nuclear industry, medicine, and biomedical research. We study mathematical modeling of a micro-SPECT system by using a point-spread function (PSF) and implement an OSEM-based iterative algorithm for image reconstruction with resolution recovery. Unlike other known implementations of the OSEM algorithm, we apply en efficient computation scheme based on a useful approximation of the PSF, which ensures relatively fast computations. The proposed approach can be applied with the data acquired with any type of collimators, including parallel-beam fan-beam, cone-beam and pinhole collimators. Experimental results obtained with a micro SPECT system demonstrate high efficiency of resolution recovery. (authors)

  7. Comparison of 18F-FDG PET and 201 thallium chloride SPECT in the evaluation of cerebral glioma prior to surgery

    International Nuclear Information System (INIS)

    Poon, A.M.T.; Cher, L.; Berlangieri, S.U.; Fabinyi, G.; Tochon-Danguy, H.; Chan, J.G.; Scott, A.M.

    2000-01-01

    Full text: The purpose of the study was to compare the accuracy of 18 F-FDG PET and 201 Tl SPECT in detecting and grading primary cerebral glioma through comparison to surgical pathology. A total of 33 patients with primary cerebral glioma had 35 18 F-FDG PET/ 201 Tl SPECT scans prior to surgery. Pre-operative 18 F -FDG PET and 201 Tl SPECT studies were reviewed and compared with histologic tumour grade. Radiological comparisons were also performed when pre-operative studies were available. 17/18 patients with glioblastoma multiforme demonstrated hypermetabolic lesions on 18 F-FDG PET scan and increased thallium uptake on SPECT scan. Increased 18 F -FDG and thallium uptake were also demonstrated in patients with anaplastic astrocytoma, gemistocytic astrocytoma, and one biopsy which was difficult to grade because of small biopsy sample and co-existing radiation necrosis. In general, low grade gliomas had reduced 18 F -FDG uptake and normal thallium uptake (6/7, where two patients had tumour with hypermetabolic and hypometabolic regions). MRI correctly identified 4/7 patients with low to intermediate grade glioma. Pilocytic astrocytoma, protoplastic astrocytoma and oligoastrocytoma all demonstrated hypometabolic PET activity and normal thallium uptake. In conclusion, 18 F-FDG PET and 201 Tl SPECT are very sensitive in pre-operative prediction of high grade glioma. In low grade tumour, 201 Tl SPECT appeared to be less useful in the absence of breakdown of the blood brain barrier. MR imaging accurately identified the presence of tumour but was less accurate in determining the grade of tumour. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  8. Rapid gated Thallium-201 perfusion SPECT - clinically feasible?

    International Nuclear Information System (INIS)

    Wadhwa, S.S.; Mansberg, R.; Fernandes, V.B.; Wilkinson, D.; Abatti, D.

    1998-01-01

    Full text: Standard dose energy window optimised Thallium-201 (Tl-201) SPECT has about half the counts of a standard dose from Technetium-99m Sestamibi (Tc99m-Mibi) gated perfusion SPECT. This study investigates the clinical feasibility of rapid energy window optimised Tl-201 gated perfusion SPECT (gated-TI) and compares quantitative left ventricular ejection fraction (LVEF) and visually assessed image quality for wall motion and thickening to analogous values obtained from Tc99m-Mibi gated perfusion SPECT (gated - mibi). Methods: We studied 60 patients with a rest gated Tl-201 SPECT (100 MBq, 77KeV peak, 34% window, 20 sec/projection) followed by a post stress gated Sestamibi SPECT (1GBq, 140KeV, 20% window, 20 sec/projection) separate dual isotope protocol. LVEF quantitation was performed using commercially available software (SPECTEF, General Electric). Visual grading of image quality for wall thickening and motion was performed using a three-point scale (excellent, good and poor). Results: LVEF for gated Tl-201 SPECT was 59.6 ± 12.0% (Mean ± SD). LVEF for gated Sestamibi SPECT was 60.4 ±11.4% (Mean ± SD). These were not significantly different (P=0.27, T-Test). There was good correlation (r=0.9) between gated-TI and gated-mibi LVEF values. The quality of gated-Tl images was ranked as excellent, good and poor in 12, 50 and 38% of the patients respectively. Image quality was better in gated-mibi SPECT, with ratings of 12, 62 and 26% respectively. Conclusion: Rapid gated Thallium-201 acquisition with energy window optimisation can be effectively performed on majority of patients and offers the opportunity to assess not only myocardial perfusion and function, as with Technetium based agents, but also viability using a single day one isotope protocol

  9. Role of SPECT imaging in symptomatic posterior element lumbar stress injuries

    Directory of Open Access Journals (Sweden)

    Debnath U

    2005-01-01

    Full Text Available Background : Diagnosis of stress injuries of spine is very difficult with conventional radiography. Methods : In a observational study, 132 subjects were recruited (between 8 and 38 years of age, who had lumbar spondylolysis or posterior element stress injuries. All these patients underwent clinical examination followed by plain X-rays, planar bone scintigraphy and SPECT (single photon emission computerised tomography. SPECT scans can identify the posterior element lumbar stress injuries earlier than other imaging modalities. As the lesions evolve and the completed spondylolysis becomes chronic, the SPECT scans tend to revert to normal even though healing of the defect has not occurred. The aim of the study was to determine the time lag after which SPECT imaging tends to be negative. We divided the patients into two groups, one SPECT positive group and the other SPECT negative group. Pre treatment background variables such as age, gender, back pain in extension or flexion, sporting activities, time of onset of symptoms, Oswestry Disability Index (ODI were used in a univariate logistic regression model to find the strong predictors of positive SPECT imaging results. Determinants of positivity versus negativity of SPECT were identified by discriminant analysis using multivariate logistic regression. Results : Seventy nine patients had positive SPECT scans whereas 53 patients had negative SPECT scans. Bilateral increased uptake was more common than unilateral uptake. Increased uptake at the L5 lumbar spine was more common (70% in SPECT positive group. Low back pain in extension was significantly more common in SPECT positive subjects. Active sporting individuals had higher probability of having a positive SPECT scan. The mean time lag from the onset of low back pain to SPECT imaging was 7 months in SPECT positive group and 25 months in the SPECT negative group. Multivariate analysis predicted that there is a significant difference in positivity of

  10. Assessment of takotsubo (ampulla) cardiomyopathy using iodine-123 metaiodobenzylguanidine scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Pessoa, Pinheiro M.C.; Xavier, Salles S.; Lima, Souza Leao R.; Mansur, J.; Almeida, Altino S. de; Carvalho, Pires A.C.; Gutfilen, B.; Fonseca, Barbosa L.M. da [Hospital Univ. Clementino Fraga Filho, Univ. Federal do Rio de Janeiro (Brazil). Dept. de Radiologia

    2006-12-15

    Purpose: To evaluate the role of cardiac sympathetic innervation in patients whose clinical features consisted of chest pain, transient ST-segment elevation, left ventricular apical akinesis, minimal elevation of cardiac enzymes, and onset of symptoms shortly after a severe stress condition. Material and Methods: Five female patients, mean age 67{+-}14 years, underwent thoracic {sup 123}I-MIBG (planar and SPECT) and 67Ga citrate (planar) scans within 5 days after the onset of symptoms. The {sup 123}I-MIBG myocardial washout rate between early (30 min) and delayed (3 hours) planar images was calculated. All patients presented findings consistent with takotsubo-like syndrome. Echocardiograms showed the characteristic wall motion pattern of significant apical dysfunction. Acute-phase coronary angiographies revealed a non-obstructive pattern. A peculiar apical akinesis and basal normokinesis were observed on the ventriculograms. Results: Impairment of cardiac neuronal uptake of {sup 123}I-MIBG based on a reduction of the heart-to-mediastinum uptake ratio was observed in all patients, while the washout rate was raised in four patients. All patients presented an apical uptake defect in the {sup 123}I-MIBG SPECT and planar images and a normal 67Ga scintigraphy. Conclusion: Our data indicate that ampulla cardiomyopathy (AC) is associated with a cardiac sympathetic innervation deficit characterized by a reduced global {sup 123}I-MIBG uptake and an apical uptake defect. The lack of 67Ga uptake in the acute phase of this syndrome indicates that AC is probably not associated with an inflammatory process.

  11. Potential pitfalls of steatopygia on bone imaging using Tc99m MDP and role of SPECT

    International Nuclear Information System (INIS)

    Elgazzar, H; Elsaid, M; Omar, A; Al-Maskery, IB

    2004-01-01

    Body habbitus influence the quality of bone scintigraphy. Steatopygia (steato: fat, pygia: buttocks) may affect the quality of bone scan since it may lead to diagnostic pitfalls. Objective: The objective of this prospective study is to evaluate the effects of steatopygia on the appearance of the lumbar spine on bone scan and the role of SPECT in overcoming fat attenuation artifact if present. Method: Bone scintigraphy, including whole body bone scan, spot views and SPECT of the lumber spine, using a dual head gamma camera, were performed on thirty adult obese patients (13 males, 17 females) with an average weight of 90 kg. referred to the department for routine bone scan. Each patient was injected intravenously with 0.25 mCi/kg (9.25 Mbq of Tc-99m MDP, and their weight and height of each patient were recorded. Whole body scan was performed using 256 X 1024 matrix size and 8 min/meter speed. SPECT was performed using 128 X 128 matrix size, 20 second-32 projections and elliptical orbit around the lumbar spine. Spot views were acquired using 256X256 matrix size for 1000 Kcounts. Results: Twenty patients (67%) (6 males, 14 females) showed steatopygia with attenuation at the lower lumber vertebrae. Diminished uptake in the lower lumbar spine and edge effect artifacts were noted on planar images mimicking abnormalities. SPECT, especially in the sagittal axis, resolved these artifacts. Conclusion: Steatopygia should be considered in the interpretation of bone scans of obese patients to avoid diagnostic pitfalls. Adding SPECT of the lumber spine to the planar imaging improves the diagnostic accuracy in obese patients by overcoming the steatopygia effect seen on whole body and spot planar images. (authors)

  12. Development of a hybrid sputtering/evaporation process for Cu(In,Ga)Se{sub 2} thin film solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Acciarri, M.; Binetti, S.; Le Donne, A.; Lorenzi, B.; Caccamo, L.; Miglio, L. [Dipartimento di Scienza dei Materiali e Solar Energy Research Center MIB-SOLAR, Universita di Milano Bicocca, Milan (Italy); Moneta, R.; Marchionna, S.; Meschia, M. [Voltasolar s.r.l, Turate (Italy)

    2011-08-15

    In this paper we report a new method for Cu(In,Ga)Se{sub 2} deposition for solar cell application. Differently from the common co-evaporation process, an alterative approach for thin film Cu(In,Ga)Se{sub 2} has been tested: the sputtering deposition of metal elements combined with the selenium evaporation. We have studied the relationships between the growth parameters of our hybrid sputtering/evaporation method and the chemical-physical properties of the CIGS films. The cells are completed with a CdS buffer layer deposited by chemical bath deposition and ZnO + ITO deposited by RF sputtering. Test solar cells of 0.5 cm{sup 2} have shown an efficiency of 10% and 2.5% on glass and stainless steel substrate respectively. (copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  13. Support vector machine-based classification of neuroimages in Alzheimer’s disease: direct comparison of FDG-PET, rCBF-SPECT and MRI data acquired from the same individuals

    Directory of Open Access Journals (Sweden)

    Luiz K. Ferreira

    2017-10-01

    Full Text Available Objective: To conduct the first support vector machine (SVM-based study comparing the diagnostic accuracy of T1-weighted magnetic resonance imaging (T1-MRI, F-fluorodeoxyglucose-positron emission tomography (FDG-PET and regional cerebral blood flow single-photon emission computed tomography (rCBF-SPECT in Alzheimer’s disease (AD. Method: Brain T1-MRI, FDG-PET and rCBF-SPECT scans were acquired from a sample of mild AD patients (n=20 and healthy elderly controls (n=18. SVM-based diagnostic accuracy indices were calculated using whole-brain information and leave-one-out cross-validation. Results: The accuracy obtained using PET and SPECT data were similar. PET accuracy was 68∼71% and area under curve (AUC 0.77∼0.81; SPECT accuracy was 68∼74% and AUC 0.75∼0.79, and both had better performance than analysis with T1-MRI data (accuracy of 58%, AUC 0.67. The addition of PET or SPECT to MRI produced higher accuracy indices (68∼74%; AUC: 0.74∼0.82 than T1-MRI alone, but these were not clearly superior to the isolated neurofunctional modalities. Conclusion: In line with previous evidence, FDG-PET and rCBF-SPECT more accurately identified patients with AD than T1-MRI, and the addition of either PET or SPECT to T1-MRI data yielded increased accuracy. The comparable SPECT and PET performances, directly demonstrated for the first time in the present study, support the view that rCBF-SPECT still has a role to play in AD diagnosis.

  14. .i.Daphnia./i. hybridization along ecological gradients in pelagic environments: the potential for the presence of hybrid zones in plankton

    Czech Academy of Sciences Publication Activity Database

    Petrusek, A.; Seďa, Jaromír; Macháček, Jiří; Ruthová, Š.; Šmilauer, P.

    2008-01-01

    Roč. 363, č. 1505 (2008), s. 2931-2941 ISSN 0962-8436 R&D Projects: GA ČR(CZ) GA206/04/0190 Institutional research plan: CEZ:AV0Z60170517 Keywords : interspecific hybridization * Daphnia longispina complex * hybrid zones * canyon-shaped reservoirs * ITS-RFLP * allozyme electrophoresis Subject RIV: EH - Ecology, Behaviour Impact factor: 5.556, year: 2008

  15. Evaluation of the diagnostic performance of SPECT coupled to tomodensitometry (SPECT-CT) in the daily practice of bone scintigraphy at the Nuclear Medical station of Nancy

    International Nuclear Information System (INIS)

    Netter, F.; Journo, A.; Mayer, J.C.; Grandpierre, S.; Daragon, N.; Karcher, G.; Olivier, P.; Scigliano, S.

    2008-01-01

    Objective: The purpose of our study was to evaluate the diagnostic performance of SPECT coupled to computed axial tomography (SPECT- CT) in our daily practice of bone scintigraphy. Subjects and methods: SPECT- CT obtained as a complement to the planar bone scintigraphy in 39 patients were studied. Each type of image was retrospectively read by two different observers: a nuclear medicine physician who was unaware of SPECT- CT results analysed planar bone scintigraphy, a second one who was unaware of planar bone scintigraphy results analysed SPECT- CT images. In this population of patients, 17 patients were addressed in an oncologic setting. The 22 other patients were addressed for pain of indeterminate origin without neoplastic context. Results: In 13% of the cases, SPECT- CT specified the precise location of increased uptake foci seen on planar bone scintigraphy. In 38% of cases, SPECT- CT confirmed a diagnosis suspected by the planar bone scintigraphy. In 10% of cases, SPECT- CT established a diagnosis that was uncertain with planar bone scintigraphy. In 26% of cases, SPECT- CT brought no additional information. Finally in 3% of cases, SPECT- CT proved to be more sensitive than planar images. Conclusion: Our study demonstrates the utility of SPECT- CT in the daily practice of bone scintigraphy, this complementary imaging study benefited to 74% of our patients. (authors)

  16. Serial cerebral hemodynamic change after extracranial-intracranial (EC-IC) bypass surgery: evaluated by acetazolamide stress brain perfusion SPECT(acz-SPECT)

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Il Ki; Kim, Jae Seung; Ahn, Jae Sung; Im, Ki Chun; Kim, Euy Nyong; Mun, Dae Hyeog [Asan Medical Center, Seoul (Korea, Republic of)

    2005-07-01

    We evaluated serial cerebral hemodynamic changes after EC-IC bypass surgery in symptomatic pts with atherosclerotic occlusion of internal carotid (lCA) or mid-cerebral artery (MCA) using Acz-SPECT. 25 symptomatic pts (M/F 19/6, 53{+-}10 y) with ICA and MCA occlusion (16 uni - and 9 bilateral) prospectively underwent Acz-SPECT using Tc-99m ECD before and 1 week after EC-IC bypass surgery. Of these, 16 underwent additional f/u Acz-SPECT 5 mo later. Cerebral perfusion and perfusion reserve of MCA territory were evaluated visually and SPECT findings were classified into 4 groups: N/N; R/N; N/R; and R/R (perfusion/perfusion reserve: N = normal, R = reduced). For semiquantitative analysis, all SPECT images were normalized to MNI template and mean counts of MCA territory and cerebellum were obtained by AAL. Cerebral perfusion index (PI =C{sub region}/C{sub cere}) and perfusion reserve index (RI = (PI{sub Acz} - PI{sub basal}) /Pl{sub basal}) were calculated. Preop SPECT findings of ipsilateral MCA in 25 pts were R/N (4%), N/R (12%), and R/R (84% ). Early postop SPECT showed improvement of perfusion (26%) and/or reserve (68%) in ipsilateral MCA. Of 16 pts with 5mo f/u SPECT, 6 (38%) showed further improvement of perfusion or reserve. However, 4 (25%) showed aggravation of perfusion and one of these underwent revision surgery. Preop PI (1.1{+-}0.1) and RI (0.11{+-}0.07) of ipsilateral MCA were significantly lower than those of contralateral hemispheres (p<0.05). After surgery, PIs of bilateral MCA did not change at early postop period but improved in ipsilateral MCA at 5mo. Rls of ipsilateral MCA increased significantly (68%) at early postop period (P<0.001) and then did not changed. Cerebral perfusion and perfusion reserve changed with different manner during 5 mo after bypass surgery and perfusion reserve changed more dramatically than perfusion. Acz-SPECT is a feasible method for evaluating cerebral hemodynamic change after EC-IC bypass surgery.

  17. SPECT in patients with cortical visual loss.

    Science.gov (United States)

    Silverman, I E; Galetta, S L; Gray, L G; Moster, M; Atlas, S W; Maurer, A H; Alavi, A

    1993-09-01

    Single-photon emission computed tomography (SPECT) with 99mTc-hexamethylpropyleneamine oxime (HMPAO) was used to investigate changes in cerebral blood flow in seven patients with cortical visual impairment. Traumatic brain injury (TBI) was the cause of cortical damage in two patients, cerebral ischemia in two patients and carbon monoxide (CO) poisoning, status epilepticus and Alzheimer's Disease (AD) each in three separate patients. The SPECT scans of the seven patients were compared to T2-weighted magnetic resonance image (MRI) scans of the brain to determine the correlation between functional and anatomical findings. In six of the seven patients, the qualitative interpretation of the SPECT studies supported the clinical findings (i.e., the visual field defect) by revealing altered regional cerebral blood flow (rCBF) in the appropriate regions of the visual pathway. MR scans in all of the patients, on the other hand, were either normal or disclosed smaller lesions than those detected by SPECT. We conclude that SPECT may reveal altered rCBF in patients with cortical visual impairment of various etiologies, even when MRI studies are normal or nondiagnostic.

  18. Noninvasive evaluation of ischemic stroke with SPECT

    International Nuclear Information System (INIS)

    Gomez, C.R.; Malik, M.M.; Gomez, S.M.; Wingkun, E.C.

    1988-01-01

    Technetium Tc 99m DTPA single photon emission computerized tomography (SPECT) brain scans of 20 patients with acute ischemic stroke were reviewed retrospectively and compared with clinical and radiologic (CT) data. Fourteen of the patients had abnormal SPECT studies. The abnormal findings were demonstrated by static views in eight patients, by the flow study in one patient, and by both sets of images in the other five patients. All abnormalities correlated with the clinical syndrome of presentation, and only two of the patients had no corresponding lesions on CT. Of the six patients with normal SPECT scans, two had abnormal CT studies, and in the other four, no lesions were shown at all. The ability of /sup 99m/Tc DTPA SPECT to display cerebral infarctions appears to be, at best, comparable to that of CT. SPECT also provides qualitative information regarding flow dynamics in the affected hemisphere of some patients (6/20 in our review). This, we believe, represents the objective demonstration of the preexisting insufficient collateral flow in the hemisphere at risk for ischemic stroke

  19. MediSPECT: Single photon emission computed tomography system for small field of view small animal imaging based on a CdTe hybrid pixel detector

    International Nuclear Information System (INIS)

    Accorsi, R.; Autiero, M.; Celentano, L.

    2007-01-01

    We describe MediSPECT, a new scanner developed at University and INFN Napoli, for SPECT studies on small animals with a small field of view (FOV) and high spatial resolution. The CdTe pixel detector (a 256x256 matrix of 55 μm square pixels) operating in single photon counting for detection of gamma-rays with low and medium energy (e.g. 125 I, 27-35 keV, 99m Tc, 140 keV), is bump bonded to the Medipix2 readout chip. The FOV of the MediSPECT scanner with a coded aperture mask collimator ranges from 6.3 mm (system spatial resolution 110 μm at 27-35 keV) to 24.3 mm. With a 0.30 mm pinhole the FOV ranges from 2.4 to 29 mm (where the system spatial resolution is 1.0 mm at 27-35 keV and 2.0 mm at 140 keV). MediSPECT will be used for in vivo imaging of small organs or tissue structures in mouse, e.g., brain, thyroid, heart or tumor

  20. Occult Candida thyroid abscess diagnosed by gallium-67 scanning

    International Nuclear Information System (INIS)

    Bach, M.C.; Blattner, S.

    1990-01-01

    A clinically silent fungal thyroid abscess was identified by Ga-67 citrate scanning and successfully drained surgically in a young leukemic patient. Whole-body radionuclide scanning remains a valuable method to help diagnose persistent fever in the immunocompromised host