WorldWideScience

Sample records for hvdc transmission system

  1. An Initial Topology of Multi-terminal HVDC Transmission System in Europe

    DEFF Research Database (Denmark)

    Irnawan, Roni; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2016-01-01

    In this paper, technical challenges for realizing offshore multi-terminal HVDC (MTDC) transmission system in Europe is evaluated. An offshore MTDC topology is projected by interconnecting point-to-point HVDC links with the same voltage level and technology found in south-eastern part of North Sea...

  2. Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems

    DEFF Research Database (Denmark)

    Sharifabadi, Kamran; Harnefors, Lennart; Nee, Hans-Peter

    Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems is a comprehensive guide to semiconductor technologies applicable for MMC design, component sizing control, modulation, and application of the MMC technology for HVDC transmission. Separated into three...... distinct parts, the first offers an overview of MMC technology, including information on converter component sizing, Control and Communication, Protection and Fault Management, and Generic Modelling and Simulation. The second covers the applications of MMC in offshore WPP, including planning, technical...... and economic requirements and optimization options, fault management, dynamic and transient stability. Finally, the third chapter explores the applications of MMC in HVDC transmission and Multi Terminal configurations, including Supergrids....

  3. Design, control and application of modular multilevel converters for HVDC transmission systems

    CERN Document Server

    Sharifabadi, Kamran; Nee, Hans-Peter; Norrga, Staffan; Teodorescu, Remus

    2016-01-01

    Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems is a comprehensive guide to semiconductor technologies applicable for MMC design, component sizing control, modulation, and application of the MMC technology for HVDC transmission. Separated into three distinct parts, the first offers an overview of MMC technology, including information on converter component sizing, Control and Communication, Protection and Fault Management, and Generic Modelling and Simulation. The second covers the applications of MMC in offshore WPP, including planning, technical and economic requirements and optimization options, fault management, dynamic and transient stability. Finally, the third chapter explores the applications of MMC in HVDC transmission and Multi Terminal configurations, including Supergrids.

  4. Performance Analysis of a Voltage Source Converter (VSC based HVDC Transmission System under Faulted Conditions

    Directory of Open Access Journals (Sweden)

    Amiri RABIE

    2009-12-01

    Full Text Available Voltage Source Converter (VSC based HVDC transmission technology hasbeen selected as the basis for several recent projects due to its controllability,compact modular design, ease of system interface, and low environmentalimpact. This paper investigates the dynamic performance of a 200MW,±100kV VSC-HVDC transmission system under some faulted conditionsusing MATLAB/Simulink. Simulation results confirm the satisfactoryperformance of the proposed system under active and reactive powervariations and fault conditions.

  5. HVDC power transmission technology assessment

    Energy Technology Data Exchange (ETDEWEB)

    Hauth, R.L.; Tatro, P.J.; Railing, B.D. [New England Power Service Co., Westborough, MA (United States); Johnson, B.K.; Stewart, J.R. [Power Technologies, Inc., Schenectady, NY (United States); Fink, J.L.

    1997-04-01

    The purpose of this study was to develop an assessment of the national utility system`s needs for electric transmission during the period 1995-2020 that could be met by future reduced-cost HVDC systems. The assessment was to include an economic evaluation of HVDC as a means for meeting those needs as well as a comparison with competing technologies such as ac transmission with and without Flexible AC Transmission System (FACTS) controllers. The role of force commutated dc converters was to be assumed where appropriate. The assessment begins by identifying the general needs for transmission in the U.S. in the context of a future deregulated power industry. The possible roles for direct current transmission are then postulated in terms of representative scenarios. A few of the scenarios are illustrated with the help of actual U.S. system examples. non-traditional applications as well as traditional applications such as long lines and asynchronous interconnections are discussed. The classical ``break-even distance`` concept for comparing HVDC and ac lines is used to assess the selected scenarios. The impact of reduced-cost converters is reflected in terms of the break-even distance. This report presents a comprehensive review of the functional benefits of HVDC transmission and updated cost data for both ac and dc system components. It also provides some provocative thoughts on how direct current transmission might be applied to better utilize and expand our nation`s increasingly stressed transmission assets.

  6. HVDC transmission power conversion applications in power systems

    CERN Document Server

    Kim, Chan-Ki; Jang, Gil-Soo; Lim, Seong-Joo; Lee, Seok-Jin

    2009-01-01

    HVDC is a critical solution to several major problems encountered when trying to maintain systemic links and quality in large-scale renewable energy environments. HDVC can resolve a number of issues, including voltage stability of AC power networks, reducing fault current, and optimal management of electric power, ensuring the technology will play an increasingly important role in the electric power industry. To address the pressing need for an up-to-date and comprehensive treatment of the subject, Kim, Sood, Jang, Lim and Lee have collaborated to produce this key text and reference.  Combin

  7. A novel power control strategy of Modular Multi-level Converter in HVDC-AC hybrid transmission systems for passive networks

    DEFF Research Database (Denmark)

    Hu, Zhenda; Wu, Rui; Yang, Xiaodong

    2014-01-01

    With the development of High Voltage DC Transmission (HVDC) technology, there will be more and more HVDC-AC hybrid transmission system in the world. A basic challenge in HVDC-AC hybrid transmission systems is to optimize the power sharing between DC and AC lines, which become more severe when sup...

  8. Power Flow Analysis of HVAC and HVDC Transmission Systems for Offshore WindParks

    DEFF Research Database (Denmark)

    da Silva, Filipe Miguel Faria; Castro, Rui

    2009-01-01

    As the onshore wind resource is running shorter, wind power promoters are paying attention to the offshore resources. As in most cases there is no load offshore, wind power must be transmitted to the main land. To do so, two options are available: HVAC and HVDC transmission systems. In this paper...... that HVAC solution is limited by the distance to shore and by the wind transmitted power. HVDC options do not show these limitations, but are more expensive and more delicate to deal with, because there is a lack of operational experience, so far....

  9. A novel synthetic test system for thyristor level in the converter valve of HVDC power transmission

    Directory of Open Access Journals (Sweden)

    Liu Longchen

    2016-01-01

    Full Text Available The converter valve is the core equipment in the HVDC power transmission system, a+-nd its performance has a direct effect on the reliability, stability and efficiency of the whole power system. As the basic unit of HVDC converter valve, the thyristor level needs to be test routinely in order to grasp the state of the converter valve equipment. Therefore, it is urgent to develop a novel synthetic test system for the thyristor level with thyristor control unit (TCU. However, currently there is no specific test scheme for the thyristor level of HVDC converter valve. In this paper, the synthetic test principle, content and methods for the thyristor level with TCU are presented based on the analysis of the thyristor reverse recovery characteristic and the IEC technology standard. And a transient high-voltage pulse is applied to the thyristor level during its reverse recovery period in order to test the characteristics of thyristor level. Then, the synthetic test system for the thyristor level is applied to the converter valve test of ±800 kV HVDC power transmission project, and the practical test result verifies the reasonability and validity of the proposed synthetic test system.

  10. HVDC: A key solution in future transmission systems

    Energy Technology Data Exchange (ETDEWEB)

    Heyman, Olof H.; Weimers, Lars; Bohl, Mie-Lotte

    2010-09-15

    With the transition of power grids, based on sustainable generation, HVDC is a key technology with new applications. This includes connection of remote wind parks and strengthening of existing AC grids. In addition, traditional applications, such as bulk hydropower transfer and interconnections between regions, play a major role in our transition to sustainable generation and the associated grids. The technology for regional grids with a limited number of nodes is already in place and commercial projects are commissioned. For extensive grids, development and verification are ongoing in parallel to industry standards being discussed in groups such as ENTSO-E and CIGRE.

  11. African HVDC system world's largest. [533 kV, 1440 km transmission line

    Energy Technology Data Exchange (ETDEWEB)

    1977-04-15

    Africa now has an HVDC transmission system whose design is unique in some respects. It operates at the highest dc voltage ever utilized, stretches across a longer distance than any other dc line, and will ultimately deliver more power than any similar project yet anticipated. The HVDC line 1,440 km long, transmits the bulk of the output of the Cabora Bassa hydro complex now being developed on the Zambezi River in Mozambique. There, an underground powerplant has been constructed that will generate 2,000 MW when its final stage of development is completed in early 1979. This figure can later be doubled by construction of a sister powerplant at the same dam. In the near future, nearly all the Cabora Bassa output will be exported to the Republic of South Africa.

  12. A GTO-based scheme for small power tapping from HVDC transmission systems

    Science.gov (United States)

    Agha Ebrahimi, Mohammad Reza

    Ever since the High Voltage Direct Current (HVDC) Transmission Systems were developed and utilized in power systems, power tapping from these transmission systems, be it for supplying isolated communities and/or loads in the vicinity of the transmission system, or to pick up dispersed generation, has presented formidable technical, as well as economical challenges to power system designers. As the size of the intermediate load, or local generation, has decreased, the severity of these challenges has increased. During the years different methods to achieve tapping have been proposed and studied. To this date, however, no practical small tapping station has been commissioned in any HVDC transmission system. The current study, deals with this problem by paying special attention to the new semiconductor technologies available on the market, which have made the production of powerful thyristors with turn off capability, i.e. Gate Turn Off Thyristors, or GTO thyristors, possible. A tapping scheme, using GTO thyristor switches, is proposed, and using the PSCAD/EMTDC digital simulation software package, the operation of the proposed scheme is studied. Simulation results prove the practicality of the proposed scheme and the quality of the power being tapped into a small local load is within the acceptable limits. The performance of the control systems, have been studied and found to be satisfactory. Also, the use of a customized air-core transformer, with a diameter of 5 m, to feed loads of up to 600 kW is shown to be possible. The tapping station is found to be unable to impose any significant negative effect on the performance of the main HVDC system.

  13. Suggested Methods for Preventing Core Saturation Instability in HVDC Transmission Systems

    Energy Technology Data Exchange (ETDEWEB)

    Norheim, Ian

    2002-07-01

    In this thesis a study of the HVDC related phenomenon core saturation instability and methods to prevent this phenomenon is performed. It is reason to believe that this phenomenon caused disconnection of the Skagerrak HVDC link 10 August 1993. Internationally, core saturation instability has been reported at several HVDC schemes and thorough complex studies of the phenomenon has been performed. This thesis gives a detailed description of the phenomenon and suggest some interesting methods to prevent the development of it. Core saturation instability and its consequences can be described in a simplified way as follows: It is now assumed that a fundamental harmonic component is present in the DC side current. Due to the coupling between the AC side and the DC side of the HVDC converter, a subsequent second harmonic positive-sequence current and DC currents will be generated on the AC side. The DC currents will cause saturation in the converter transformers. This will cause the magnetizing current to also have a second harmonic positive-sequence component. If a high second harmonic impedance is seen from the commutation bus, a high positive-sequence second harmonic component will be present in the commutation voltages. This will result in a relatively high fundamental frequency component in the DC side voltage. If the fundamental frequency impedance at the DC side is relatively low the fundamental component in the DC side current may become larger than it originally was. In addition the HVDC control system may contribute to the fundamental frequency component in the DC side voltage, and in this way cause a system even more sensitive to core saturation instability. The large magnetizing currents that eventually will flow on the AC side cause large zero-sequence currents in the neutral conductors of the AC transmission lines connected to the HVDC link. This may result in disconnection of the lines. Alternatively, the harmonics in the large magnetizing currents may cause

  14. Interactions Between Indirect DC-Voltage Estimation and Circulating Current Controllers of MMC-Based HVDC Transmission Systems

    DEFF Research Database (Denmark)

    Wickramasinghe, Harith R.; Konstantinou, Georgios; Pou, Josep

    2018-01-01

    Estimation-based indirect dc-voltage control in MMCs interacts with circulating current control methods. This paper proposes an estimation-based indirect dc-voltage control method for MMC-HVDC systems and analyzes its performance compared to alternative estimations. The interactions between......-state and transient performance is demonstrated using a benchmark MMC-HVDC transmission system, implemented in a real-time digital simulator. The results verify the theoretical evaluations and illustrate the operation and performance of the proposed indirect dc-voltage control method....

  15. improvement of power system quality using vsc-based hvdc ...

    African Journals Online (AJOL)

    HOD

    2. DESCRIPTION OF VSC-BASED HVDC LINK. The principal characteristic of VSC-HVDC transmission is its ability to independently control the reactive and real power flow at each of the AC systems to which it is connected, at the Point of Common Coupling (PCC). In contrast to line-commutated HVDC transmission, the.

  16. Offshore VSC-HVDC Networks : Impact on Transient Stability of AC Transmission Systems

    NARCIS (Netherlands)

    van der Meer, A.A.

    2017-01-01

    The transition towards a sustainable society calls for the massive deployment of renewable energy sources such as large wind parks located far offshore. High-voltage direct current transmission based on voltage sourced converter technology (VSC-HVDC) offers a wide range of technological benefits

  17. A method of Modelling and Simulating the Back-to-Back Modular Multilevel Converter HVDC Transmission System

    Science.gov (United States)

    Wang, Lei; Fan, Youping; Zhang, Dai; Ge, Mengxin; Zou, Xianbin; Li, Jingjiao

    2017-09-01

    This paper proposes a method to simulate a back-to-back modular multilevel converter (MMC) HVDC transmission system. In this paper we utilize an equivalent networks to simulate the dynamic power system. Moreover, to account for the performance of converter station, core components of model of the converter station gives a basic model of simulation. The proposed method is applied to an equivalent real power system.

  18. Comparative study of superconducting fault current limiter both for LCC-HVDC and VSC-HVDC systems

    Science.gov (United States)

    Lee, Jong-Geon; Khan, Umer Amir; Lim, Sung-Woo; Shin, Woo-ju; Seo, In-Jin; Lee, Bang-Wook

    2015-11-01

    High Voltage Direct Current (HVDC) system has been evaluated as the optimum solution for the renewable energy transmission and long-distance power grid connections. In spite of the various advantages of HVDC system, it still has been regarded as an unreliable system compared to AC system due to its vulnerable characteristics on the power system fault. Furthermore, unlike AC system, optimum protection and switching device has not been fully developed yet. Therefore, in order to enhance the reliability of the HVDC systems mitigation of power system fault and reliable fault current limiting and switching devices should be developed. In this paper, in order to mitigate HVDC fault, both for Line Commutated Converter HVDC (LCC-HVDC) and Voltage Source Converter HVDC (VSC-HVDC) system, an application of resistive superconducting fault current limiter which has been known as optimum solution to cope with the power system fault was considered. Firstly, simulation models for two types of LCC-HVDC and VSC-HVDC system which has point to point connection model were developed. From the designed model, fault current characteristics of faulty condition were analyzed. Second, application of SFCL on each types of HVDC system and comparative study of modified fault current characteristics were analyzed. Consequently, it was deduced that an application of AC-SFCL on LCC-HVDC system with point to point connection was desirable solution to mitigate the fault current stresses and to prevent commutation failure in HVDC electric power system interconnected with AC grid.

  19. HVDC power transmission environmental issues review

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, W.H.; Weil, D.E. [Bailey Research Associates, Inc., New York, NY (United States); Stewart, J.R. [Power Technologies, Inc., Schenectady, NY (United States)

    1997-04-01

    This report strives to define the various environmental effects associated with HVDC lines, discusses the current knowledge of their potential effects on biological and non-biological systems, and compares these effects associated with ac lines where appropriate.

  20. Steady-state operational range evolution from a two-terminal to a multiterminal HVDC transmission system

    DEFF Research Database (Denmark)

    Irnawan, Roni; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2017-01-01

    DC grids are anticipated to grow organically with one possible initial configuration being formed by interconnecting an additional HVDC converter into an existing shore-to-shore (StS) HVDC link. In order to ensure the performance of this MTDC system, the DC voltage at each converter terminal with...

  1. Fault ride-through and grid support of permanent magnet synchronous generator-based wind farms with HVAC and VSC-HVDC transmission systems

    DEFF Research Database (Denmark)

    Liu, Hongzhi; Chen, Zhe

    2012-01-01

    This paper describes fault ride-through and grid support of offshore wind farms based on permanent magnet synchronous generator (PMSG) wind turbines connected to the onshore AC network through two alternative transmission systems: high voltage AC (HVAC) or high voltage DC (HVDC) based on voltage...

  2. AC Transmission Emulation Control Strategies for the BTB VSC HVDC System in the Metropolitan Area of Seoul

    Directory of Open Access Journals (Sweden)

    Sungyoon Song

    2017-08-01

    Full Text Available In the Korean power system, growing power loads have recently created the problems of voltage instability and fault current in the Seoul Capital Area (SCA. Accordingly, the back-to-back (BTB voltage source converter (VSC high-voltage direct-current (HVDC system is emerging to resolve such problems with grid segmentation. However, non-convergence problems occur in this metropolitan area, due to the large change of power flow in some contingencies. Therefore, this paper proposes two kinds of AC transmission emulation control (ATEC strategies to improve the metropolitan transient stability, and to resolve the non-convergence problem. The proposed ATEC strategies are able to mitigate possible overloading of adjacent AC transmission, and maintain power balance between metropolitan regions. The first ATEC strategy uses a monitoring system that permits the reverse power flow of AC transmission, and thus effectively improves the grid stability based on the power transfer equation. The second ATEC strategy emulates AC transmission with DC link capacitors in a permissible DC-link voltage range according to angle difference, and securely improves the gird stability, without requiring grid operator schedule decisions. This paper compares two kinds of ATEC schemes: it demonstrates the first ATEC strategy with specific fault scenario with PSS/E (Power Transmission System Planning Software, and evaluates the second ATEC strategy with internal controller performance with PSCAD/EMTDC (Power System Electromagnetic Transients Simulation Software.

  3. A self-coordinating adaptive control scheme for HVDC transmission systems

    Energy Technology Data Exchange (ETDEWEB)

    Meah, Kala [Electrical and Computer Engineering, York College of Pennsylvania, York, PA (United States); Sadrul Ula, A.H.M. [Electrical and Computer Engineering, University of Wyoming, Laramie, WY (United States)

    2009-11-15

    The transients in a HVDC system can temporarily change line currents, voltages, and power substantially from the reference steady state values and the behavior of the system depends greatly upon the parameters of the converter controller. The DC system performances are affected by the AC system characteristics such as the short circuit ratio, and the AC system inertia. A controller which has good performance for a particular operating condition may not have sufficiently good performance under another operating condition or vice versa. Performance of the controller also depends on the impedance at the rectifier and the inverter bus, which may vary according to the operating conditions of the AC network. A controller with self-coordinating adaptive capability can perform better in various situations. The proposed controller is tested at a very low SCR, the most critical value for system performance evaluation, and at the low inertia of the AC system. Simulation results are compared between proposed controller, fuzzy tuned controller, gain scheduling controller, and fixed-parameter controller. All simulations are conducted using MATLAB/SIMULINK software package. (author)

  4. A Flexible Power Control Method of VSC-HVDC Link for the Enhancement of Effective Short-Circuit Ratio in a Hybrid Multi-Infeed HVDC System

    DEFF Research Database (Denmark)

    Liu, Yan; Chen, Zhe

    2013-01-01

    With the emerging use of voltage source converter high voltage direct current (VSC-HVDC) links, the hybrid multi-infeed HVDC (HMIDC) system that includes the line commutated converter (LCC) HVDC and the VSC-HVDC links is becoming a promising power transmission structure in the modern power systems......, based on the calculation results, a flexible power control strategy for the VSC-HVDC link is developed to provide maximum reactive power support under grid faults. The theoretical analysis of the HMIDC system is based on the Danish transmission grid, evaluated through PSCAD simulations under different...... grid fault conditions. Simulation results are presented to validate the expected performance of the proposed method....

  5. Optimisation of VSC-HVDC Transmission for Wind Power Plants

    OpenAIRE

    Silva, Rodrigo da

    2012-01-01

    Connection of Wind Power Plants (WPP), typically oshore, using VSCHVDC transmission is an emerging solution with many benefits compared to the traditional AC solution, especially concerning the impact on control architecture of the wind farms and the grid.The VSC-HVDC solution is likely to meet more stringent grid codes than a conventional AC transmission connection. The purpose of this project is to analyse how HVDC solution, considering the voltage-source converter based technology, for gri...

  6. Insulation coordination in installations for hvdc power transmission

    Energy Technology Data Exchange (ETDEWEB)

    Neise, W.; Povh, D.; Sarbach, E.

    1968-01-01

    Principal considerations on insulation coordination in installations for hvdc power transmission are discussed. Measures which may be taken for the limitation of overvoltages are explained. An arrester for hvdc power transmission is described and its characteristics are indicated. Starting from the protective levels for arresters can be used and which protective levels can be realized. Under consideration of a usual safety margin, the withstand voltages of the components of the installation can thus be indicated.

  7. Simulation of a rectifier malfunction on an offshore wind system with HVDC transmission

    OpenAIRE

    Melicio, Rui

    2015-01-01

    A new integrated mathematical model for the simulation of an offshore wind system having a rectifier input voltage malfunction at one phase is presented in this paper. The mathematical model considers an offshore variable-speed wind turbine on a floating platform, equipped with a permanent magnet synchronous generator using full-power three-level converter to inject energy into the electric network, through a high voltage direct current transmission submarine cable. The model for the drive tr...

  8. Power Delivery in Multiterminal VSC-HVDC Transmission System for Offshore Wind Power Applications

    DEFF Research Database (Denmark)

    Silva, Rodrigo Da; Teodorescu, Remus; Rodriguez, Pedro

    2010-01-01

    This paper deals with one of the challenges in the field of offshore wind power systems: power transmission among the wind farms and the land when there is more than one AC grid to be considered. This case is known in the literature as multiterminal connection. The proposed studies are going...... to present three strategies in order to connect one offshore wind farm and two AC grids with different power ratings. The first strategy shows the easier case when one onshore station defines the power transmission and it is followed by the situation when droop control is applied. The final scheme is focused...... on the technique which a central power control is able to manage the onshore stations. The results are compared using EMTDCPSCAD platform....

  9. Stability analysis of multi-infeed HVDC system applying VSC-HVDC

    DEFF Research Database (Denmark)

    Liu, Yan; Chen, Zhe

    2010-01-01

    This paper presents a general model of dual infeed HVDC system applying VSC-HVDC, which can be used as an element in large multi infeed HVDC system. The model may have different structure under different grid faults because of the action of breakers. Hence power flow of the system based on this m......This paper presents a general model of dual infeed HVDC system applying VSC-HVDC, which can be used as an element in large multi infeed HVDC system. The model may have different structure under different grid faults because of the action of breakers. Hence power flow of the system based...... on this model is analyzed under steady state and different kinds of grid fault transient situations. Two main control methods applied on VSC-HVDC link in this dual infeed HVDC system are investigated, and comparative analysis of them under transient situation is presented. A simulation model is built in PSCAD....../EMTDC to verify the theoretical analysis. Simulation results indicate that this dual infeed HVDC system can realize higher stability than single infeed HVDC system. And different control strategies on a VSC-HVDC link may result in different influence on AC voltage and active power oscillation during transient...

  10. Comparison of PI and PR current controllers applied on two-level VSC-HVDC transmission system

    DEFF Research Database (Denmark)

    Manoloiu, A.; Pereria, H.A.; Teodorescu, Remus

    2015-01-01

    This paper analyzes differences between αβ and dq reference frames regarding the control of two-level VSC-HVDC current loop and dc-link voltage outer loop. In the first part, voltage feedforward effect is considered with PI and PR controllers. In the second part, the feedforward effect is removed...... and the PR gains are tuned to keep the dynamic performance. Also, the power feedforward is removed and the outer loop PI controller is tuned in order to maintain the system dynamic performance. The paper is completed with simulation results, which highlight the advantages of using PR controller....

  11. Application of Grey Wolf Optimizer Algorithm for Optimal Power Flow of Two-Terminal HVDC Transmission System

    Directory of Open Access Journals (Sweden)

    Heba Ahmed Hassan

    2017-01-01

    Full Text Available This paper applies a relatively new optimization method, the Grey Wolf Optimizer (GWO algorithm for Optimal Power Flow (OPF of two-terminal High Voltage Direct Current (HVDC electrical power system. The OPF problem of pure AC power systems considers the minimization of total costs under equality and inequality constraints. Hence, the OPF problem of integrated AC-DC power systems is extended to incorporate HVDC links, while taking into consideration the power transfer control characteristics using a GWO algorithm. This algorithm is inspired by the hunting behavior and social leadership of grey wolves in nature. The proposed algorithm is applied to two different case-studies: the modified 5-bus and WSCC 9-bus test systems. The validity of the proposed algorithm is demonstrated by comparing the obtained results with those reported in literature using other optimization techniques. Analysis of the obtained results show that the proposed GWO algorithm is able to achieve shorter CPU time, as well as minimized total cost when compared with already existing optimization techniques. This conclusion proves the efficiency of the GWO algorithm.

  12. Advanced solutions in power systems HVDC, facts, and artificial intelligence

    CERN Document Server

    Liu, Chen-Ching; Edris, Abdel-Aty

    2016-01-01

    Provides insight on both classical means and new trends in the application of power electronic and artificial intelligence techniques in power system operation and control This book presents advanced solutions for power system controllability improvement, transmission capability enhancement and operation planning. The book is organized into three parts. The first part describes the CSC-HVDC and VSC-HVDC technologies, the second part presents the FACTS devices, and the third part refers to the artificial intelligence techniques. All technologies and tools approached in this book are essential for power system development to comply with the smart grid requirements.

  13. Short Circuit Ratio analysis of multi-infeed HVDC system with a VSC-HVDC link

    DEFF Research Database (Denmark)

    Liu, Yan; Chen, Zhe

    2011-01-01

    -infeed HVDC system stability has been analyzed a lot but the study on ESCR of this kind of system is still insufficient. This paper presents a calculation method for ESCR of the hybrid multi infeed HVDC system based on a simple two-infeed HVDC system model. The equivalent circuit of this system under short......As an important indicator of system stability, Short Circuit Ratio (SCR) is commonly used in power system analysis. For systems include HVDC link connection, the Effective SCR (ESCR) is mostly applied to indicate the strength of HVDC infeed bus. The contribution of VSC-HVDC link to multi...... circuit situation is firstly obtained based on the model. Then its Thevenin equivalent circuit is derived and system ESCR can be calculated. At last, simulation study verified that the calculated ESCR value under different cases can indicate the change of system stability....

  14. Power control method on VSC-HVDC in a hybrid multi-infeed HVDC system

    DEFF Research Database (Denmark)

    Liu, Yan; Chen, Zhe

    2012-01-01

    Multi-infeed HVDC (MIDC) system connected with VSC-HVDC links and LCC-HVDC links is a new structure in modern power systems, which can be called hybrid multi-infeed HVDC (HMIDC) system. The paper presents the voltage stability analysis of a HMIDC system modeled from a possible future Danish power...... stability of the system with induction machine loads. The proposed power control method based on a VSC power circle makes fully use of the VSC-HVDC capacity to support system voltage during fault situations. Simulation model of the studied HMIDC system is built in PSCAD. Simulation studies under different...... system and proposes a power control method to improve the system voltage stability. Dynamic loads are considered in the studied system and represented by induction machines. The paper analyses voltage recovery process of an induction machine during a fault and gives the necessary condition of the voltage...

  15. Design of protective inductors for HVDC transmission line within DC grid offshore wind farms

    DEFF Research Database (Denmark)

    Deng, Fujin; Chen, Zhe

    2013-01-01

    This paper presents fault analysis and protective inductors design for an offshore wind farm, where the power collection system in the wind farm and the power transmission link to the grid adopt high-voltage direct-current (HVDC) technology. This paper focuses on dealing with short-circuit faults...

  16. Wind Farm Grid Integration Using VSC Based HVDC Transmission - An Overview

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay Kumar; Teodorescu, Remus; Rodriguez, Pedro

    2008-01-01

    The paper gives an overview of HVAC and HVDC connection of wind farm to the grid, with an emphasis on Voltage Source Converter (VSC)-based HVDC for large wind farms requiring long distance cable connection. Flexible control capabilities of a VSC-based HVDC system enables smooth integration of win...... farm into the power grid network while meeting the Grid Code Requirements (GCR). Operation of a wind farm with VSC-based HVDC connection is described....

  17. Simulative Study into the Development of a Hybrid HVDC System Through a Comparative Research with HVAC: a Futuristic Approach

    Directory of Open Access Journals (Sweden)

    R. S. Narayan

    2017-06-01

    Full Text Available High Voltage Direct Current Transmission (HVDC is considered a better solution for bulk long distance transmissions. The increased use of HVDC is a result of its advantages over the HVAC systems and especially of its fault stability nature. A better solution is proposed by using a Voltage Source Controlled–HVDC as one of the infeed for the Multi-Infeed HVDC (MIDC or MI-HVDC systems. The main advantage with the VSC converter is its flexible power control which enhances the stability of the MIDC systems. In this paper, the behavior of an HVDC system is compared with that of an HVAC during faults. A Hybrid HVDC system that includes a LCC as a rectifier unit and a VSC converter as the inverter is being proposed. It is considered suitable for MIDC systems and particularly for supplying a weak AC system. The performance of the system during steady state and transient conditions for all the proposed topologies including HVDC, HVAC and Hybrid HVDC are studied in MATLAB/SIMULINK. All of the proposed control strategies are evaluated via a series of simulation case studies.

  18. Coordinated Control Strategies for Offshore Wind Farm Integration via VSC-HVDC for System Frequency Support

    DEFF Research Database (Denmark)

    Li, Yujun; Xu, Zhao; Østergaard, Jacob

    2017-01-01

    Coordinated control strategies to provide system inertia support for main grid from offshore wind farm that is integrated through HVdc transmission is the subject matter of this paper. The strategy that seeks to provide inertia support to the main grid through simultaneous utilization of HVdc...... scheme. Both strategies can effectively provide inertia support while the second one minimizes the control impacts on harvesting wind energy with the aid of communication between onshore and offshore ac grids. Case studies of a wind farm connecting with a HVdc system considering sudden load variations...... have been successfully conducted to compare and demonstrate the effectiveness of the control strategies in DIgSILENT/PowerFactory....

  19. Modular VSC converter based HVDC power transmission from offshore wind power plant: Compared to the conventional HVAC system

    DEFF Research Database (Denmark)

    Sharma, Ranjan; Rasmussen, Tonny Wederberg; Jensen, Kim Høj

    2010-01-01

    The size of wind power plants (WPPs), both physical and in terms of power rating, is rapidly growing. More and more WPPs are commissioned as offshore as well as the distances from the WPP to the coast are increasing. The problems associated with long HVAC sea-cables are well documented. Alternative...... and the energy losses. A complete procedure of evaluating the energy transmission as well as losses in both systems are presented. A brief discussion about the limitations of HVAC transmission is also included in the paper together with advantages and disadvantages of both systems....

  20. Optimisation of VSC-HVDC Transmission for Wind Power Plants

    DEFF Research Database (Denmark)

    Silva, Rodrigo Da

    more stringent grid codes than a conventional AC transmission connection. The purpose of this project is to analyse how HVDC solution, considering the voltage-source converter based technology, for grid connection of large wind power plants can be designed and optimised. By optimisation, the project...... of large networks in order to design the control parameters of voltage source converters. This technique, based in structure singular values and the control design by means of -synthesis, presents as disadvantages the use of higher order controllers. On the other hand, the improvements in the dynamic...

  1. DC Vs AC - War Of Currents For Future Power Systems A HVDC Technology Overview

    Directory of Open Access Journals (Sweden)

    Anil K. Rai

    2015-08-01

    Full Text Available DC vs AC discussion began in 1880s with development of first commercial power transmission in Wall Street New York. Later when AC technology came into notice by efforts of inventor and researcher Sir Nicola Tesla soon the advantages of AC transmission and AC devices overtook the DC technology. It was hoped that DC technology had lost battle of currents. Today with researches going on FACTS devices and bulk power transmission HVDC has again gained a reputation in power sector. Solution of this centuries old debate is to develop HVDC systems that assists HVAC systems for better performance stability and control

  2. Coordinated Control Strategies of VSC-HVDC-Based Wind Power Systems for Low Voltage Ride Through

    Directory of Open Access Journals (Sweden)

    Xinyin Zhang

    2015-07-01

    Full Text Available The Voltage Source Converter-HVDC (VSC-HVDC system applied to wind power generation can solve large scale wind farm grid-connection and long distance transmission problems. However, the low voltage ride through (LVRT of the VSC-HVDC connected wind farm is a key technology issue that must be solved, and it is currently lacking an economic and effective solution. In this paper, a LVRT coordinated control strategy is proposed for the VSC-HVDC-based wind power system. In this strategy, the operation and control of VSC-HVDC and wind farm during the grid fault period is improved. The VSC-HVDC system not only provides reactive power support to the grid, but also effectively maintains the power balance and DC voltage stability by reducing wind-farm power output, without increasing the equipment investment. Correspondingly, to eliminate the influence on permanent magnet synchronous generator (PMSG-based wind turbine (WT systems, a hierarchical control strategy is designed. The speed and validity of the proposed LVRT coordinated control strategy and hierarchical control strategy were verified by MATLAB/Simulink simulations.

  3. HVDC power transmission electrode siting and design

    Energy Technology Data Exchange (ETDEWEB)

    Holt, R.J. [NDT Engineering, Inc., Shrewbury, MA (United States); Dabkowski, J. [Electro-Sciences, Inc., Crystal Lake, IL (United States); Hauth, R.L. [New England Power Service Co., Westborough, MA (United States)

    1997-04-01

    This research strives to shed light on the feasibility and practicality of using deep earth electrodes to permit their use for extended periods without adverse consequences. This report begins with a review of the fundamentals associated with current conduction in earth, including the various techniques available for measuring the earth`s electrical properties. The sources of existing data are discussed and some specific data for selected regions of the U.S. and Canada are reviewed as examples. Electrode technology and design issues are reviewed and recent experience gained by New England Power and Hydro-Quebec is discussed. The issues associated with direct current flowing in underground pipelines (and other facilities) are described and the present-day mitigation measures are evaluated. Suggestions are made for further R&D in the coordination of cathodic protection systems, an area that has evolved as an empirical, trial- and-error art more than a science.

  4. Modelling and Simulation of SVPWM Based Vector Controlled HVDC Light Systems

    Directory of Open Access Journals (Sweden)

    Ajay Kumar MOODADLA

    2012-11-01

    Full Text Available Recent upgrades in power electronics technology have lead to the improvements of insulated gate bipolar transistor (IGBT based Voltage source converter High voltage direct current (VSC HVDC transmission systems. These are also commercially known as HVDC Light systems, which are popular in renewable, micro grid, and electric power systems. Out of different pulse width modulation (PWM schemes, Space vector PWM (SVPWM control scheme finds growing importance in power system applications because of its better dc bus utilization. In this paper, modelling of the converter is described, and SVPWM scheme is utilized to control the HVDC Light system in order to achieve better DC bus utilization, harmonic reduction, and for reduced power fluctuations. The simulations are carried out in the MATLAB/SIMULINK environment and the results are provided for steady state and dynamic conditions. Finally, the performance of SVPWM based vector controlled HVDC Light transmission system is compared with sinusoidal pulse width modulation (SPWM based HVDC Light system in terms of output voltage and total harmonic distortion (THD.

  5. HVDC-System-Interaction Assessment through Line-Flow Change-Distribution Factor and Transient-Stability Analysis at Planning Stage

    Directory of Open Access Journals (Sweden)

    Sungchul Hwang

    2016-12-01

    Full Text Available Many of the recent projects for new transmission line have considered the high-voltage direct current (HVDC system, owing to the many advantages of the direct current (DC system. The most noteworthy advantage is that a cable can serve as a substitute for the overhead transmission line in residential areas; therefore, the HVDC system application is increasing, and as the number of DC systems in the power system increases, the interaction assessment regarding the HVDC system gains importance. An index named multi-infeed interaction factor (MIIF is commonly used to estimate the interaction between power converters; however, the HVDC system is composed of two converters and a transmission line. The MIIF represents the interaction between the rectifiers and inverters, but not for the whole system. In this work, a method to assess the interaction of the whole system was therefore studied. To decide on the location of the new HVDC transmission system at the planning stage, in consideration of the interaction of the existing DC system, the line flow change distribution factor, according to the HVDC-transmission capacity change, was examined. Also, a power system transient -stability analysis was performed with different HVDC system locations, depending on the distribution factor. The simulation results indicate that when the factor is higher, two HVDC systems have a stronger interaction and are less stable in the transient state.

  6. Optimal Power Transmission of Offshore Wind Power Using a VSC-HVdc Interconnection

    National Research Council Canada - National Science Library

    Miguel E. Montilla-DJesus; Santiago Arnaltes; Edgardo D. Castronuovo; David Santos-Martin

    2017-01-01

    High-voltage dc transmission based on voltage-source converter (VSC-HVdc) is quickly increasing its power rating, and it can be the most appropriate link for the connection of offshore wind farms (OWFs...

  7. Simulation of offshore wind farm integrated into power grid using VSC HVDC system

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Hui; Nguyen, Mau Cuong; Rudion, Krzystof; Styczynski, Zbigniew Antoni [Magdeburg Univ. (Germany). Chair for Electric Power Networks and Renewable Energy Sources

    2011-07-01

    In this paper, the integration of an offshore wind farm into a power grid is studied based on the simulation of a developed test system including an aggregated DFIG wind farm model and VSC HVDC transmission system model. This paper concentrates on the transient stability and system performance with an applied controller for DFIG and HVDC converter stations. The results are obtained by simulation of the test system subjected to severe grid disturbance, e.g. three-phase short circuit fault at the point of common coupling (PCC). Furthermore, the conformity of the system performance with the current grid code, e.g. fault-ride through capability is investigated and confirmed from the simulation results. In addition, a DC-chopper circuit is modeled to protect the HVDC-link from the overvoltage without disconnection during grid faults. Different time delays of the DC-chopper are considered and simulated to investigate its influence on the system dynamics and performance. (orig.)

  8. Improved Power Flow Algorithm for VSC-HVDC System Based on High-Order Newton-Type Method

    Directory of Open Access Journals (Sweden)

    Yanfang Wei

    2013-01-01

    Full Text Available Voltage source converter (VSC based high-voltage direct-current (HVDC system is a new transmission technique, which has the most promising applications in the fields of power systems and power electronics. Considering the importance of power flow analysis of the VSC-HVDC system for its utilization and exploitation, the improved power flow algorithms for VSC-HVDC system based on third-order and sixth-order Newton-type method are presented. The steady power model of VSC-HVDC system is introduced firstly. Then the derivation solving formats of multivariable matrix for third-order and sixth-order Newton-type power flow method of VSC-HVDC system are given. The formats have the feature of third-order and sixth-order convergence based on Newton method. Further, based on the automatic differentiation technology and third-order Newton method, a new improved algorithm is given, which will help in improving the program development, computation efficiency, maintainability, and flexibility of the power flow. Simulations of AC/DC power systems in two-terminal, multi-terminal, and multi-infeed DC with VSC-HVDC are carried out for the modified IEEE bus systems, which show the effectiveness and practicality of the presented algorithms for VSC-HVDC system.

  9. A Pilot Directional Protection for HVDC Transmission Line Based on Relative Entropy of Wavelet Energy

    Directory of Open Access Journals (Sweden)

    Sheng Lin

    2015-07-01

    Full Text Available On the basis of analyzing high-voltage direct current (HVDC transmission system and its fault superimposed circuit, the direction of the fault components of the voltage and the current measured at one end of transmission line is certified to be different for internal faults and external faults. As an estimate of the differences between two signals, relative entropy is an effective parameter for recognizing transient signals in HVDC transmission lines. In this paper, the relative entropy of wavelet energy is applied to distinguish internal fault from external fault. For internal faults, the directions of fault components of voltage and current are opposite at the two ends of the transmission line, indicating a huge difference of wavelet energy relative entropy; for external faults, the directions are identical, indicating a small difference. The simulation results based on PSCAD/EMTDC show that the proposed pilot protection system acts accurately for faults under different conditions, and its performance is not affected by fault type, fault location, fault resistance and noise.

  10. improvement of power system quality using vsc-based hvdc

    African Journals Online (AJOL)

    HOD

    converters, each one at a link terminal, for AC/DC and DC/AC conversion The principal characteristic of VSC-HVDC transmission is its ability to ... converter and its ability of converting electrical energy from AC to DC or vice versa. ..... waveform and FFT wave spectrum, the DC side filters blocking high-frequency are tuned to ...

  11. Voltage sensitivity based reactive power control on VSC-HVDC in a wind farm connected hybrid multi-infeed HVDC system

    DEFF Research Database (Denmark)

    Liu, Yan; Chen, Zhe

    2013-01-01

    With increasing application of both Line Commutated Converter based High Voltage Direct Current (LCC-HVDC) systems and Voltage Source Converter based HVDC (VSC-HVDC) links, a new type of system structure named Hybrid Multi-Infeed HVDC (HMIDC) system is formed in the modern power systems. This paper...... presents the operation and control method of the wind farm connected HMIDC system. The wind power fluctuation takes large influence to the system voltages. In order to reduce the voltage fluctuation of LCC-HVDC infeed bus caused by the wind power variation, a voltage sensitivity-based reactive power...

  12. Development of a Wireless Sensor Network for Distributed Measurement of Total Electric Field under HVDC Transmission Lines

    OpenAIRE

    Yong Cui; Jianxun Lv; Haiwen Yuan; Luxing Zhao; Yingyi Liu; Hao Yang

    2014-01-01

    A wireless sensor network-based distributed measurement system is designed for collecting and monitoring the electric field under the high voltage direct current (HVDC) transmission lines. The proposed system architecture is composed of a group of wireless nodes connected with electric field sensors and a base station. The electric field sensor based on Gauss’s law is elaborated and developed. For the design of wireless node, the ARM microprocessor and Zigbee radio frequency module are employ...

  13. Relative localization in wireless sensor networks for measurement of electric fields under HVDC transmission lines.

    Science.gov (United States)

    Cui, Yong; Wang, Qiusheng; Yuan, Haiwen; Song, Xiao; Hu, Xuemin; Zhao, Luxing

    2015-02-04

    In the wireless sensor networks (WSNs) for electric field measurement system under the High-Voltage Direct Current (HVDC) transmission lines, it is necessary to obtain the electric field distribution with multiple sensors. The location information of each sensor is essential to the correct analysis of measurement results. Compared with the existing approach which gathers the location information by manually labelling sensors during deployment, the automatic localization can reduce the workload and improve the measurement efficiency. A novel and practical range-free localization algorithm for the localization of one-dimensional linear topology wireless networks in the electric field measurement system is presented. The algorithm utilizes unknown nodes' neighbor lists based on the Received Signal Strength Indicator (RSSI) values to determine the relative locations of nodes. The algorithm is able to handle the exceptional situation of the output permutation which can effectively improve the accuracy of localization. The performance of this algorithm under real circumstances has been evaluated through several experiments with different numbers of nodes and different node deployments in the China State Grid HVDC test base. Results show that the proposed algorithm achieves an accuracy of over 96% under different conditions.

  14. Relative Localization in Wireless Sensor Networks for Measurement of Electric Fields under HVDC Transmission Lines

    Science.gov (United States)

    Cui, Yong; Wang, Qiusheng; Yuan, Haiwen; Song, Xiao; Hu, Xuemin; Zhao, Luxing

    2015-01-01

    In the wireless sensor networks (WSNs) for electric field measurement system under the High-Voltage Direct Current (HVDC) transmission lines, it is necessary to obtain the electric field distribution with multiple sensors. The location information of each sensor is essential to the correct analysis of measurement results. Compared with the existing approach which gathers the location information by manually labelling sensors during deployment, the automatic localization can reduce the workload and improve the measurement efficiency. A novel and practical range-free localization algorithm for the localization of one-dimensional linear topology wireless networks in the electric field measurement system is presented. The algorithm utilizes unknown nodes' neighbor lists based on the Received Signal Strength Indicator (RSSI) values to determine the relative locations of nodes. The algorithm is able to handle the exceptional situation of the output permutation which can effectively improve the accuracy of localization. The performance of this algorithm under real circumstances has been evaluated through several experiments with different numbers of nodes and different node deployments in the China State Grid HVDC test base. Results show that the proposed algorithm achieves an accuracy of over 96% under different conditions. PMID:25658390

  15. Offshore wind power plants with VSC-HVDC transmission : Grid code compliance optimization and the effect on high voltage ac transmission system

    NARCIS (Netherlands)

    Ndreko, M.

    2017-01-01

    The development of large offshore wind power generation in the North Sea has been significantly accelerated in the last years. The large distance from shore in combination with the need for large transmission capacity has raised the interest for the voltage source converter high voltage direct

  16. Multilevel Modular Converter for VSC-HVDC Transmission Applications: Control and Operational Aspects

    DEFF Research Database (Denmark)

    Gnanarathna, Udana N.; Gole, Aniruddha M.; Chaudhary, Sanjay Kumar

    2010-01-01

    Control methods for a new class of converter, the multilevel modular converter (MMC), recently introduced for HVDC transmission are discussed. The paper discusses converter-level controls including firing pulse generation and capacitor voltage balancing. It also covers higher level controls...

  17. OPF-Based Optimal Location of Two Systems Two Terminal HVDC to Power System Optimal Operation

    Directory of Open Access Journals (Sweden)

    Mehdi Abolfazli

    2013-04-01

    Full Text Available In this paper a suitable mathematical model of the two terminal HVDC system is provided for optimal power flow (OPF and optimal location based on OPF such power injection model. The ability of voltage source converter (VSC-based HVDC to independently control active and reactive power is well represented by the model. The model is used to develop an OPF-based optimal location algorithm of two systems two terminal HVDC to minimize the total fuel cost and active power losses as objective function. The optimization framework is modeled as non-linear programming (NLP and solved by Matlab and GAMS softwares. The proposed algorithm is implemented on the IEEE 14- and 30-bus test systems. The simulation results show ability of two systems two terminal HVDC in improving the power system operation. Furthermore, two systems two terminal HVDC is compared by PST and OUPFC in the power system operation from economical and technical aspects.

  18. Power system integration of VSC-HVDC connected offshore wind power plants

    DEFF Research Database (Denmark)

    Zeni, Lorenzo; Kjær, Philip Carne

    This report presents an overview of challenges and solutions for the integration into the power system of offshore wind power plants (WPPs) connected to onshore grids through a voltage-source converter based high voltage direct current (VSC-HVDC) transmission system. Aspects that are touched upon...... introduction to justify the study, describe the state-of-art and formulate the project’s objectives, the report is essentially divided into three parts, as follows. Control principles of offshore AC networks The control of offshore AC networks relies purely on power electronics, especially if Type 4 wind...... turbine generators (WTGs) are used. Assuming the WTGs are controlled in a “standard” way (based on established literature), two state-of-art control strategies for the offshore HVDC converter are compared in different operational scenarios: (Option 1) nested voltage-current control scheme based on vector...

  19. Discrete-Time Nonlinear Control of VSC-HVDC System

    Directory of Open Access Journals (Sweden)

    TianTian Qian

    2015-01-01

    Full Text Available Because VSC-HVDC is a kind of strong nonlinear, coupling, and multi-input multioutput (MIMO system, its control problem is always attracting much attention from scholars. And a lot of papers have done research on its control strategy in the continuous-time domain. But the control system is implemented through the computer discrete sampling in practical engineering. It is necessary to study the mathematical model and control algorithm in the discrete-time domain. The discrete mathematical model based on output feedback linearization and discrete sliding mode control algorithm is proposed in this paper. And to ensure the effectiveness of the control system in the quasi sliding mode state, the fast output sampling method is used in the output feedback. The results from simulation experiment in MATLAB/SIMULINK prove that the proposed discrete control algorithm can make the VSC-HVDC system have good static, dynamic, and robust characteristics in discrete-time domain.

  20. Economics and a novel voltage conversion technique associated with exporting Wyoming's energy by HVDC transmission

    Science.gov (United States)

    Xu, Kaili

    Wyoming is by far the largest coal producing state in the US, but local utilization is extremely low. As much as 92% of Wyoming's coal is shipped to the other states and is mainly consumed by their electricity producers. Coal accounts for more than 50% of the US electricity generation and is one of the least expensive energy sources. Wyoming could utilize its coal better by exporting electricity instead of exporting the coal only in its raw form. Natural gas is another important energy resource in Wyoming but local utilization is even lower. As a result of the development in coalbed methane fields, natural gas production in Wyoming is almost in pace with its coal production. In addition to constructing more new pipelines, new transmission lines should be considered as an alternative way of exporting this energy. Because of their enormous electricity market sizes and high electricity prices, California, Texas and Illinois are chosen to be the target markets for Wyoming's electricity. The proposed transmission schemes use High Voltage DC (HVDC) lines, which are suitable for long distance and cross-system power transmission. Technical and economic feasibilities are studied in details. The Wyoming-California scheme has a better return of investment than both the Wyoming-Texas and the Wyoming-Illinois schemes. A major drawback of HVDC transmission is the high level of harmonics generated by the converters. Elaborate filtering is required at both the AC and the DC sides. A novel pulse-multiplication method is proposed in the thesis to reduce the harmonics from the converter source. By introducing an averaging inductor, the proposed method uses less thyristors to achieve the same high-pulse operation as the existing series scheme. The reduction of thyristors makes the switching circuit more reliable and easier to control and maintain. Harmonic analysis shows that the harmonic level can be reduced to about one third of the original system. The proposed method is also

  1. Review of VSC HVDC Connection for Offshore Wind Power Integration

    DEFF Research Database (Denmark)

    Korompili, Asimenia; Wu, Qiuwei; Zhao, Haoran

    2016-01-01

    Voltage Source Converter (VSC) High Voltage Direct Current (HVDC) connection has become a new trend for long distance offshore wind power transmission. It has been confirmed by a lot of research that the maximum distance of a High Voltage Alternative Current (HVAC) sub-marine cable transmission...... system is limited due to surplus charging current of the cables. The VSC HVDC transmission system has the ability to overcome the limitation and offers other advantages over the HVAC transmission system. This paper is to review the VSC HVDC transmission technology and its application for offshore wind...... power integration. Firstly, the main components, configuration and topology of the VSC HVDC transmission system are described. Secondly, the converter control system and control strategies are presented. Following that, the capabilities of the VSC HVDC technology are described. Finally, the focus...

  2. Control of Multi-terminal VSC-HVDC Systems

    OpenAIRE

    Haileselassie, Temesgen Mulugeta

    2008-01-01

    The North Sea has a vast amount of wind energy with largest energy per area densities located about 100-300Km of distance from shore. Should this energy be tapped by offshore wind farms, HVDC transmission would be the more feasible solution at such long subsea distances. On the other hand Norwegian oil/gas platforms in the North Sea use electricity from gas fired turbines at offshore sites. These gas turbines have much less efficiency than onshore generation of electricity and also release la...

  3. Research on the correlation between corona current spectrum and audible noise spectrum of HVDC transmission line

    Science.gov (United States)

    Liu, Yingyi; Zhou, Lijuan; Liu, Yuanqing; Yuan, Haiwen; Ji, Liang

    2017-11-01

    Audible noise is closely related to corona current on a high voltage direct current (HVDC) transmission line. In this paper, we measured a large amount of audible noise and corona current waveforms simultaneously based on the largest outdoor HVDC corona cage all over the world. By analyzing the experimental data, the related statistical regularities between a corona current spectrum and an audible noise spectrum were obtained. Furthermore, the generation mechanism of audible noise was analyzed theoretically, and the related mathematical expression between the audible noise spectrum and the corona current spectrum, which is suitable for all of these measuring points in the space, has been established based on the electro-acoustic conversion theory. Finally, combined with the obtained mathematical relation, the internal reasons for these statistical regularities appearing in measured corona current and audible noise data were explained. The results of this paper not only present the statistical association regularities between the corona current spectrum and the audible noise spectrum on a HVDC transmission line, but also reveal the inherent reasons of these associated rules.

  4. Hard- and software of real time simulation tools of Electric Power System for adequate modeling power semiconductors in voltage source convertor based HVDC and FACTS

    Directory of Open Access Journals (Sweden)

    Ufa Ruslan A.

    2014-01-01

    Full Text Available The motivation of the presented research is based on the needs for development of new methods and tools for adequate simulation of Flexible Alternating Current Transmission System (FACTS devices and High Voltage Direct Current Transmission (HVDC system as part of real electric power systems (EPS. For that, a hybrid approach for advanced simulation of the FACTS and HVDC based on Voltage Source is proposed. The presented simulation results of the developed hybrid model of VSC confirm the achievement of the desired properties of the model and the effectiveness of the proposed solutions.

  5. HVDC grids for offshore and supergrid of the future

    CERN Document Server

    Gomis-Bellmunt, Oriol; Liang, Jun

    2016-01-01

    Presents the advantages, challenges, and technologies of High Voltage Direct Current (HVDC) Grids This book discusses HVDC grids based on multi-terminal voltage-source converters (VSC), which is suitable for the connection of offshore wind farms and a possible solution for a continent wide overlay grid. HVDC Grids: For Offshore and Supergrid of the Future begins by introducing and analyzing the motivations and energy policy drives for developing offshore grids and the European Supergrid. HVDC transmission technology and offshore equipment are described in the second part of the book. The third part of the book discusses how HVDC grids can be developed and integrated in the existing power system. The fourth part of the book focuses on HVDC grid integration, in studies, for different time domains of electric power systems. The book concludes by discussing developments of advanced control methods and control devices for enabling DC grids.

  6. High-performance HVDC transmission over long distances; Hochleistungsuebertragung ueber grosse Entfernungen mit hochgespanntem Gleichstrom

    Energy Technology Data Exchange (ETDEWEB)

    Radtke, U. [PreussenElektra AG, Hannover (Germany)

    1998-12-31

    High-voltage DC transmission is a world-wide established technology for low-cost transmission of large amounts of electricity over long distances. Thanks to HVDC transmission, large amounts of electricity can now for the first time also be transmitted over long distances via ocean cable, something that cannot be done with AC power cables. HVDC transmission is independent of grid frequencies and can link grids of different frequency and different quality of frequency. Interconnected grids coupled via DC circuits can exploit additional technical and economic advantages such as mutual supply of power reserves, balancing of peak load, and modulation of active and reactive power. (orig.) [Deutsch] Die Hochspannungs-Gleichstromuebertragung (HGUe) ist eine weltweit etablierte Technik zur kostenguenstigen Uebertragung grosser elektrischer Leistungen ueber grosse Entfernungen. Sie schafft erstmals die Moeglichkeit, auch mittels Seekabel grosse Leistungen ueber Entfernungen zu uebertragen, die mit der Drehstromtechnik nicht moeglich sind. HGUeist unabhaengig von den Netzfrequenzen und kann Netze unterschiedlicher Frequenz und Frequenzguete miteinander verbinden. Ueber Gleichstromkreise gekuppelte Verbundnetze koennen zusaetzliche technische und wirtschaftliche Vorteile wie gegenseitige Bereitstellung von Kraftwerksreserven, Spitzenlastausgleich sowie Wirk- und Blindleistungsmodulation nutzt. (orig.)

  7. Second Order Cone Programming (SOCP) Relaxation Based Optimal Power Flow with Hybrid VSC-HVDC Transmission and Active Distribution Networks

    DEFF Research Database (Denmark)

    Ding, Tao; Li, Cheng; Yang, Yongheng

    2017-01-01

    The detailed topology of renewable resource bases may have the impact on the optimal power flow of the VSC-HVDC transmission network. To address this issue, this paper develops an optimal power flow with the hybrid VSC-HVDC transmission and active distribution networks to optimally schedule...... the generation output and voltage regulation of both networks, which leads to a non-convex programming model. Furthermore, the non-convex power flow equations are based on the Second Order Cone Programming (SOCP) relaxation approach. Thus, the proposed model can be relaxed to a SOCP that can be tractably solved...

  8. The Study on Hybrid Multi-Infeed HVDC System Connecting with Offshore Wind Farm

    DEFF Research Database (Denmark)

    Liu, Yan

    ) Modeling the HMIDC system connecting with an offshore wind farm, and investigating the main factors that affect the system stability under the different disturbances. 2) On the basis of the stability analysis, developing the appropriate control strategies for the studied HMIDC system in order to enhance...... the stability analysis of the basic HMIDC system, the research work moves forward to the control of the HMIDC system comprising the offshore wind farm at the sending end of the VSCHVDC link. In this case, the Low Voltage Ride Through (LVRT) ability of the VSC-HVDC connected wind farm is one of the most...... the large offshore wind farms, thanks to their flexibility on controlling active and reactive power. Hence, together with the existing LCC-HVDC links, a new power system structure, also named as the Hybrid Multi-Infeed HVDC system, can be envisioned, where both the LCC- and VSC-HVDC links terminate...

  9. Review of VSC HVDC Connection for Offshore Wind Power Integration

    DEFF Research Database (Denmark)

    Korompili, Asimenia; Wu, Qiuwei; Zhao, Haoran

    2016-01-01

    Voltage Source Converter (VSC) High Voltage Direct Current (HVDC) connection has become a new trend for long distance offshore wind power transmission. It has been confirmed by a lot of research that the maximum distance of a High Voltage Alternative Current (HVAC) sub-marine cable transmission...... system is limited due to surplus charging current of the cables. The VSC HVDC transmission system has the ability to overcome the limitation and offers other advantages over the HVAC transmission system. This paper is to review the VSC HVDC transmission technology and its application for offshore wind...... is given on the control methods of the VSC HVDC transmission system for fulfilling grid code requirements concerning Low Voltage Ride-Through (LVRT) and frequency regulation....

  10. Offshore Wind Farms and HVDC Grids Modeling as a Feedback Control System for Stability Analysis

    DEFF Research Database (Denmark)

    Bidadfar, Ali; Saborío-Romano, Oscar; Altin, Müfit

    control schemes and may lead the entire system to instability. Assessing the stability and adopting complex coordinated control schemes in an HVDC grid and wind farm turbines are challenging and require a precise model of the HVDC grid, wind farm, and the controllers. In this paper, a linear multivariable...... feedback control system (FCS) model is proposed to represent the dynamic characteristics of HVDC grids and their controllers. The FCS model can be used for different dynamic analyses in time and frequency domains. Moreover, using the FCS model the system stability is analyzed in both open- and closed......-loop forms. The standard eigenanalysis identifies the modes of only the closed-loop system and detects the pertaining state variables. The open-loop model, in the frequency domain, is a complementary tool that helps to have more intuitive insight into the system stability. A four terminal HVDC grid with two...

  11. Improvement of Wind Energy Production through HVDC Systems

    Directory of Open Access Journals (Sweden)

    Morris Brenna

    2017-01-01

    Full Text Available Variable and non-programmable resources, such as solar and wind, have undergone a stunning growth in recent years and are likely to gain even more importance in the future. Their strong presence in the national electricity mix has created issues in many countries regarding the secure operation of the power system. In order to guarantee the stability of the system, several TSOs have resorted to wind energy curtailment, which represents a waste of clean energy and an economic loss. In order to analyze this issue, a model of the Italian power system was developed, a program able to simulate the electricity dispatching mechanism. The model was, then, used to evaluate possible solutions to reduce wind curtailment. In particular, a proposal for the construction of an HVDC line linking Southern and Northern Italy was studied.

  12. Mitigation of commutation failures in LCC-HVDC systems based on superconducting fault current limiters

    Science.gov (United States)

    Lee, Jong-Geon; Khan, Umer Amir; Lee, Ho-Yun; Lim, Sung-Woo; Lee, Bang-Wook

    2016-11-01

    Commutation failure in line commutated converter based HVDC systems cause severe damages on the entire power grid system. For LCC-HVDC, thyristor valves are turned on by a firing signal but turn off control is governed by the external applied AC voltage from surrounding network. When the fault occurs in AC system, turn-off control of thyristor valves is unavailable due to the voltage collapse of point of common coupling (PCC), which causes the commutation failure in LCC-HVDC link. Due to the commutation failure, the power transfer interruption, dc voltage drop and severe voltage fluctuation in the AC system could be occurred. In a severe situation, it might cause the protection system to block the valves. In this paper, as a solution to prevent the voltage collapse on PCC and to limit the fault current, the application study of resistive superconducting fault current limiter (SFCL) on LCC-HVDC grid system was performed with mathematical and simulation analyses. The simulation model was designed by Matlab/Simulink considering Haenam-Jeju HVDC power grid in Korea which includes conventional AC system and onshore wind farm and resistive SFCL model. From the result, it was observed that the application of SFCL on LCC-HVDC system is an effective solution to mitigate the commutation failure. And then the process to determine optimum quench resistance of SFCL which enables the recovery of commutation failure was deeply investigated.

  13. DC power flow control for radial offshore multi-terminal HVDC transmission system by considering steady-state DC voltage operation range

    DEFF Research Database (Denmark)

    Irnawan, Roni; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2017-01-01

    of this MTDC system due to the inherited limit from point-to-point (PtP) configuration. An analytic method is proposed in order to estimate the steady-state DC voltage operational points of this MTDC system. The proposed method has been confirmed with a conventional DC power flow study result....

  14. Examination of fault ride-through methods for off-shore wind farms connected to the grid through VSC-based HVDC transmission

    Energy Technology Data Exchange (ETDEWEB)

    Karaagac, U.; Mahseredjian, J.; Saad, H. [Ecole Polytechnique de Montreal, QC (Canada); Jensen, S.; Cai, L. [REpower Systems AG, Hamburg (Germany)

    2012-07-01

    The fault ride-through (FRT) performance of offshore wind farms (OWFs) is a challenging task when the OWF is connected to the onshore ac grid through a voltage source converter (VSC) based HVDC transmission system. The injected power from the OWF cannot be reduced by the offshore VSC during onshore ac faults and this causes a fast increase in the dc network voltage. Without any special FRT method, the dc network voltage may increase up to intolerable levels and cause operation of dc overvoltage protection. This paper compares various FRT methods based on fast reduction of power generation in OWFs. In addition, this paper proposes an improved FRT method based on controlled voltage drop for output power reduction in OWFs. The proposed improvement reduces mechanical stress on the wind turbine (WT) drive train, and electrical stress on the insulated gate bipolar transistors (IGBTs) of the HVDC and doubly-fed induction generator (DFIG) converters. Practical onshore ac fault scenarios are simulated for an OWF composed of DFIG type WTs and connected to a practical ac grid through a point-to-point modular multilevel converter (MMC) based HVDC system. (orig.)

  15. Stability Enhancement of Multi machine AC Systems by Synchronverter HVDC control

    Directory of Open Access Journals (Sweden)

    Raouia Aouini

    2016-06-01

    Full Text Available This paper investigates the impact of the Synchronverter based HVDC control on power system stability. The study considers multi machine power systems, with realistic parameters. A specific tuning method of the parameters of the regulators is used. The proposed control scheme is based on the sensitivity of the poles of the HVDC neighbor zone to the control parameters, and next, on their placement using residues. The transient stability of the HVDC neighbor zone is a priori taken into account at the design stage. The new tuning method is evaluated in comparison with the standard vector control via simulation tests. Extensive tests are performed using Matlab/Simulink implementation of the IEEE 9 bus/3 machines test system. The results prove the superiority of the proposed control to the classic vector control. The synchronverter control allows to improve not only the local performances of the HVDC link, but also the overall transient stability of the AC zone in which the HVDC is inserted. (where

  16. Coordinated system services from offshore wind power plants connected through HVDC networks

    DEFF Research Database (Denmark)

    Zeni, L.; Glasdam, Jakob Bærholm; Hesselbæk, B.

    2014-01-01

    system, or an OWPP, or both. Moreover, the implementation of power oscillation damping (POD) and HVDC voltage control into an OWPP controller is proposed, discussing the main challenges related to their efficient design. Dynamic control challenges are assessed, in particular in relation to the inherent......, its combination with OWPPs, against a conventional power station of comparable size. Consequently it will be pointed out what features will be critical for TSOs when partially or completely replacing conventional units with HVDC stations connected to neighbouring systems and/or OWPPs.......This paper presents an overview of power system services in networks involving multiple onshore power systems, a voltage sourced converter (VSC) based high voltage direct current (HVDC) offshore network and an offshore wind power plant (OWPP). A comprehensive list of services regarding onshore...

  17. An Annotated Bibliography of HVDC Transmission and FACTS Devices, 1996-1997.

    Energy Technology Data Exchange (ETDEWEB)

    Litzenberger, Wayne H.; Varma, Rajiv K.; Flanagan, John D. [eds.

    1998-06-01

    This edition of the Annotated Bibliography of HVDC Transmission and FACTS Devices continues work begun in 1962 by the late Erik Bromberg, Bonneville Power Administration Librarian. His original bibliography covered the period 1932--1962. Subsequent editions were compiled by Bromberg, Val S. Lava, and Wayne Litzenberger, all of Bonneville Power Administration. Beginning with the 1991--1993 edition, the scope of the bibliography was expanded to include flexible ac transmission (FACTS) devices. This 1996--1997 edition also contains information for 1998. Preparation of the present edition took place primarily in May-June of 1998. All pertinent references have been included that were available to the editors at the time of preparation. Papers for the 1998 IEEE Winter and Summer Power Meetings and 1998 T and D Conference have been included. This edition contains the organizational affiliation of the first-named author as an aid to accessing the reference. Unfortunately, space limitations prevented the inclusion of the affiliations of all authors. Some minor editorial changes have been made to abstracts to ensure consistency in style and syntax.

  18. Coordinated system services from offshore wind power plants connected through HVDC networks

    DEFF Research Database (Denmark)

    Zeni, Lorenzo; Glasdam, Jakob; Hesselbæk, Bo

    2014-01-01

    control and communication delays of OWPPs, and their influence on the successful delivery of the targeted services. Furthermore, it is shown that as an HVDC network increases in size from the point-to-point, the handling of onshore short circuits calls for the proper combination of DC chopper(s) and fast......, its combination with OWPPs, against a conventional power station of comparable size. Consequently it will be pointed out what features will be critical for TSOs when partially or completely replacing conventional units with HVDC stations connected to neighbouring systems and/or OWPPs.......This paper presents an overview of power system services in networks involving multiple onshore power systems, a voltage sourced converter (VSC) based high voltage direct current (HVDC) offshore network and an offshore wind power plant (OWPP). A comprehensive list of services regarding onshore...

  19. Contribution of VSC-HVDC to Frequency Regulation of Power Systems With Offshore Wind Generation

    DEFF Research Database (Denmark)

    Liu, Hongzhi; Chen, Zhe

    2015-01-01

    capacitors of VSC-HVdc are controlled to absorb or release energy so as to provide frequency support. To further enhance the system frequency response, the frequency support from VSC-HVdc is also finely coordinated with that from offshore wind farm according to the latency of offshore wind farm responding......Modern large wind farms are required to provide frequency regulation service like conventional synchronous generation units. The frequency support capability of modern wind farms has been widely investigated and implemented. Remotely located large offshore wind farms are probably connected......, the stability and security of the power system will be put at risk, especially for those with high wind penetration. This paper proposes a coordinated control scheme to allow VSC-HVdc link to contribute to the system frequency regulation by adjusting its dc-link voltage. By means of this approach, the dc...

  20. Non-Pilot Protection of the HVDC Grid

    Science.gov (United States)

    Badrkhani Ajaei, Firouz

    This thesis develops a non-pilot protection system for the next generation power transmission system, the High-Voltage Direct Current (HVDC) grid. The HVDC grid protection system is required to be (i) adequately fast to prevent damages and/or converter blocking and (ii) reliable to minimize the impacts of faults. This study is mainly focused on the Modular Multilevel Converter (MMC) -based HVDC grid since the MMC is considered as the building block of the future HVDC systems. The studies reported in this thesis include (i) developing an enhanced equivalent model of the MMC to enable accurate representation of its DC-side fault response, (ii) developing a realistic HVDC-AC test system that includes a five-terminal MMC-based HVDC grid embedded in a large interconnected AC network, (iii) investigating the transient response of the developed test system to AC-side and DC-side disturbances in order to determine the HVDC grid protection requirements, (iv) investigating the fault surge propagation in the HVDC grid to determine the impacts of the DC-side fault location on the measured signals at each relay location, (v) designing a protection algorithm that detects and locates DC-side faults reliably and sufficiently fast to prevent relay malfunction and unnecessary blocking of the converters, and (vi) performing hardware-in-the-loop tests on the designed relay to verify its potential to be implemented in hardware. The results of the off-line time domain transients studies in the PSCAD software platform and the real-time hardware-in-the-loop tests using an enhanced version of the RTDS platform indicate that the developed HVDC grid relay meets all technical requirements including speed, dependability, security, selectivity, and robustness. Moreover, the developed protection algorithm does not impose considerable computational burden on the hardware.

  1. Impact of Offshore Wind Power Integrated by VSC-HVDC on Power Angle Stability of Power Systems

    Science.gov (United States)

    Lu, Haiyang; Tang, Xisheng

    2017-05-01

    Offshore wind farm connected to grid by VSC-HVDC loses frequency support for power system, so adding frequency control in wind farm and VSC-HVDC system is an effective measure, but it will change wind farm VSC-HVDC’s transient stability on power system. Through theoretical analysis, concluding the relationship between equivalent mechanical power and electromagnetic power of two-machine system with the active power of wind farm VSC-HVDC, then analyzing the impact of wind farm VSC-HVDC with or without frequency control and different frequency control parameters on angle stability of synchronous machine by EEAC. The validity of theoretical analysis has been demonstrated through simulation in PSCAD/EMTDC.

  2. A Review on VSC-HVDC Reliability Modeling and Evaluation Techniques

    Science.gov (United States)

    Shen, L.; Tang, Q.; Li, T.; Wang, Y.; Song, F.

    2017-05-01

    With the fast development of power electronics, voltage-source converter (VSC) HVDC technology presents cost-effective ways for bulk power transmission. An increasing number of VSC-HVDC projects has been installed worldwide. Their reliability affects the profitability of the system and therefore has a major impact on the potential investors. In this paper, an overview of the recent advances in the area of reliability evaluation for VSC-HVDC systems is provided. Taken into account the latest multi-level converter topology, the VSC-HVDC system is categorized into several sub-systems and the reliability data for the key components is discussed based on sources with academic and industrial backgrounds. The development of reliability evaluation methodologies is reviewed and the issues surrounding the different computation approaches are briefly analysed. A general VSC-HVDC reliability evaluation procedure is illustrated in this paper.

  3. A Two-Dimensional Cloud Model for Condition Assessment of HVDC Converter Transformers

    Directory of Open Access Journals (Sweden)

    Linjie Zhao

    2012-01-01

    Full Text Available Converter transformers are the key and the most important components in high voltage direct current (HVDC power transmission systems. Statistics show that the failure rate of HVDC converter transformers is approximately twice of that of transformers in AC power systems. This paper presents an approach integrated with a two-dimensional cloud model and an entropy-based weight model to evaluate the condition of HVDC converter transformers. The integrated approach can describe the complexity of HVDC converter transformers and achieve an effective assessment of their condition. Data from electrical testing, DGA, oil testing, and visual inspection were chosen to form the double-level assessment index system. Analysis results show that the integrated approach is capable of providing a relevant and effective assessment which in turn, provides valuable information for the maintenance of HVDC converter transformers.

  4. Grid Integration of Offshore Wind Farms via VSC-HVDC – Dynamic Stability Study

    DEFF Research Database (Denmark)

    Liu, Hongzhi

    farms could seriously impact the operation and stability of their interconnected power system. To assist in maintaining the power system stability when large disturbances occur in the grid, modern offshore wind farms consisting of variable-speed wind turbines are required to provide ancillary services......-HVDC transmission are addressed. The main objectives have been to study the dynamic interactions between offshore wind farms and interconnected power systems, pinpoint the impact on the electrical grid while integrating large-scale offshore wind farms via VSC-HVDC link and propose potential solutions to improve...... the dynamic stability of the network. This research work starts with the modelling of full converter wind turbine and VSC-HVDC transmission system. Then, based on those models, the impact of integration of a large offshore wind farm into the power system through VSC-HVDC transmission is investigated...

  5. Review of different fault detection methods and their impact on pre-emptive VSC-HVDC dc protection performance

    OpenAIRE

    Chang, Bin; Cwikowski, Oliver; Barnes, Mike; Shuttleworth, Roger; Beddard, Antony; Coventry, P

    2017-01-01

    Multi-terminal voltage-sourced converters (VSC) high-voltage direct current (HVDC) transmission system is expected to play a vital role in future power systems. Compared with ac power transmission, dc transmission is more vulnerable to faults due to low dc-side impedances and sensitive power electronics in the converters. Dc protection issues must be tackled before any multi-terminal VSC-HVDC grid can be built. The multi-terminal VSC-HVDC system is studied in detail using switching models for...

  6. Guest editorial special section on HVDC systems for large offshore wind power plants

    OpenAIRE

    Gomis Bellmunt, Oriol; Liang, Jun; Van Hertem, Dirk; Barnes, Mike; Cutululis, Nicolaos Antonio

    2016-01-01

    © 20xx IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. The papers in this special section focus on HVDC systems for large offshore wind power plants. These plants ha...

  7. DC Voltage Droop Control Structures and its Impact on the Interaction Modes in Interconnected AC-HVDC Systems

    DEFF Research Database (Denmark)

    Thams, Florian; Chatzivasileiadis, Spyros; Eriksson, Robert

    2017-01-01

    Different dc voltage droop control structures for future multi-terminal HVDC systems have been proposed in literature. This paper contributes to the evaluation of those structures by an analysis of their impact on the coupling of the interconnected subsystems. In particular, the modes of the syst......Different dc voltage droop control structures for future multi-terminal HVDC systems have been proposed in literature. This paper contributes to the evaluation of those structures by an analysis of their impact on the coupling of the interconnected subsystems. In particular, the modes...... of the systems are classified in different subsets according to the participation of the various subsystems. Those subsets are then evaluated qualitatively and quantitatively indicating which impact the choice of the droop control structure has on the degree of coupling between the connected ac and dc systems...... respectively the different HVDC converters. The lowest damped interaction modes of the different subsets are analyzed in more detail....

  8. Power transmission and HVDC converter technology of Electric Power Development Co. Ltd. (EPDC); Dengen Kaihatsu (kabu) no genshiryoku hatsuden gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-25

    Power transmission and HVDC converter technologies of EPDC are outlined. The following technologies were developed for DC transmission: (1) the small water-cooled direct photo- ignition thyristor valve which reduced electronic parts by adopting water cooling and direct photo-ignition, (2) the tank type DC filter which improved a reliability and eliminated cleaning works by substituting a tank type filter for previous rack type one for DC linkage facilities, and (3) the digital control technology which improved the function of static reactive power compensators by substituting digital control for analog one. The multi-terminal control and protective device for linkage are under development to cope with large facilities. EPDC has constructed large-scale overhead transmission lines across channels and straits. For environmental measures and rising of towers, the super small base tower and T type base were developed on the basis of the study on tower structure. EPDC has also constructed underground (submarine) transmission facilities to link regional networks. Submarine cables, joints and laying techniques have been investigated. 3 refs., 21 figs., 9 tabs.?

  9. HVDC Solution for Offshore Wind Park Comprising Turbines Equipped with Full-Range Converters

    DEFF Research Database (Denmark)

    Sharma, Ranjan; Rasmussen, Tonny Wederberg; Jensen, Kim Høj

    2010-01-01

    This paper describes a power transmission technique from an offshore wind farm to an on-land AC (alternating current) grid through a HVDC (high voltage direct current) transmission system. The limitations of an AC transmission system for long distances are presented together with the advantages...... of a HVDC transmission system. The power system under study includes an offshore wind farm comprising turbines equipped with full range converters. The collection network is a local AC grid. Power transmission is done through HVDC system. The grid side VSC (voltage source converter) controls the DC voltage...... of the DC transmission together with the reactive power to the grid. However, the control of the wind farm side VSC needs to be adaptive. The paper presents control methods for wind farm side VSC during the normal and the fault conditions of the connecting AC grid. During normal operation, the wind farm VSC...

  10. An Annotated Bibliography of High-Voltage Direct-Current Transmission and Flexible AC Transmission (FACTS) Devices, 1991-1993.

    Energy Technology Data Exchange (ETDEWEB)

    Litzenberger, Wayne; Lava, Val

    1994-08-01

    References are contained for HVDC systems, converter stations and components, overhead transmission lines, cable transmission, system design and operations, simulation of high voltage direct current systems, high-voltage direct current installations, and flexible AC transmission system (FACTS).

  11. Coordinated control of wind power plants in offshore HVDC grids

    DEFF Research Database (Denmark)

    Sakamuri, Jayachandra N.

    2017-01-01

    was formed among nine North Sea countries. They agreed on closer energy cooperation to enable development of an efficient and economic offshore grid infrastructure for advantages, interconnectors based on the voltage source converter based high voltage DC (HVDC) transmission system is being used to exchange...

  12. Enhanced Dynamic Voltage Stability Support by VSC-HVDC for Offshore Wind Applications using Trajectory Sensitivity Analysis

    DEFF Research Database (Denmark)

    Liu, Hongzhi; Chen, Zhe; Liu, Leo

    2013-01-01

    The integration of large-scale wind power plants changes the structure, configuration and operation of conventional power systems and brings challenges to the security and stability of power systems. Dynamic voltage stability of power systems with high wind penetration is one of the critical issues....... In this paper, VSC-HVDC transmission system is used to integrate a large-scale wind power plant into the onshore power grid. For different voltage support strategies of VSC-HVDC, a trajectory sensitivity analysisbased approach is proposed to find the minimum onshore VSC capacity with which the VSC-HVDC can...

  13. Control of transformerless MMC-HVDC during asymmetric grid faults

    DEFF Research Database (Denmark)

    Timofejevs, Artjoms; Gamboa, Daniel; Liserre, Marco

    2013-01-01

    Modular multilevel converter (MMC) is the latest converter topology suitable for the transformerless applications in HVDC transmission. HVDC systems are required to remain connected during grid faults, provide grid support and completely decouple the healthy side from the faulty one. The MMC...... converter weak points are challenged by this particular condition and by these demands. This paper demonstrates the effect of negative and zero sequence current control in MMCHVDC during asymmetric grid faults. A current limitation strategy for MMC is derived and verified through simulations....

  14. Nonlinear Control of Back-to-Back VSC-HVDC System via Command-Filter Backstepping

    Directory of Open Access Journals (Sweden)

    Jie Huang

    2017-01-01

    Full Text Available This paper proposed a command-filtered backstepping controller to improve the dynamic performance of back-to-back voltage-source-converter high voltage direct current (BTB VSC-HVDC. First, the principle and model of BTB VSC-HVDC in abc and d-q frame are described. Then, backstepping method is applied to design a controller to maintain the voltage balance and realize coordinated control of active and reactive power. Meanwhile, command filter is introduced to deal with the problem of input saturation and explosion of complexity in conventional backstepping, and a filter compensation signal is designed to diminish the adverse effects caused by the command filter. Next, the stability and convergence of the whole system are proved via the Lyapunov theorem of asymptotic stability. Finally, simulation results are given to demonstrate that proposed controller has a better dynamic performance and stronger robustness compared to the traditional PID algorithm, which also proves the effectiveness and possibility of the designed controller.

  15. A Review of LCC-HVDC and VSC-HVDC Technologies and Applications

    Directory of Open Access Journals (Sweden)

    Oluwafemi Emmanuel Oni

    2016-09-01

    Full Text Available High Voltage Direct Current (HVDC systems has been an alternative method of transmitting electric power from one location to another with some inherent advantages over AC transmission systems. The efficiency and rated power carrying capacity of direct current transmission lines highly depends on the converter used in transforming the current from one form to another (AC to DC and vice versa. A well configured converter reduces harmonics, increases power transfer capabilities, and reliability in that it offers high tolerance to fault along the line. Different HVDC converter topologies have been proposed, built and utilised all over the world. The two dominant types are the line commutated converter LCC and the voltage source converter VSC. This review paper evaluates these two types of converters, their operational characteristics, power rating capability, control capability and losses. The balance of the paper addresses their applications, advantages, limitations and latest developments with these technologies.

  16. Study on electricity transmission systems for offshore wind power

    OpenAIRE

    Lleonart Pizà, Aina

    2011-01-01

    This project presents the main features of each of the electricity transmission technologies available for offshore wind power and discusses their advantages and disadvantages in terms of technical, economic and environmental aspects. The transmission options studied are High Voltage Alternating Current (HVAC) and High Voltage Direct Current (HVDC). Within the HVDC there are two transmission technologies available, the classical Line Commutated Converter based HVDC and the most re...

  17. Control System interaction in the VSC-HVDC Grid Connected Offshore Wind Power Plant

    DEFF Research Database (Denmark)

    Glasdam, Jakob Bærholm; Kocewiak, Łukasz Hubert; Hjerrild, Jesper

    2015-01-01

    or converter interaction studies have therefore become an important part of the system design studies of a high voltage alternating current (HVAC) grid connected OWPP. The voltage sourced converter high voltage direct current (VSC-HVDC) has become a preferred choice for grid connection of remotely located...... in the electrical system which is generally located within the wind turbine generator (WTG) controller bandwidth. Some of the negative impact of the existence of harmonic instability include (but not limited to) accelerated component ageing due to increased thermal stresses and loss of power production before...... the source of the instability has been identified and mitigation methods have been designed and implemented. This procedure is not straightforward and can have a long lead time. The harmonic instability can have severe economic consequences for the OWPP owner due to the large investment. Harmonic stability...

  18. Integration of a finite element generator model into a simulated HVDC connected system

    Energy Technology Data Exchange (ETDEWEB)

    Preston, T.W.; Sturgess, J.P. [GEC Alsthom Engineering Research Center, Stafford (United Kingdom)

    1994-12-31

    Within most system analysis programs generators and motors are represented by an equivalent circuit model either a 2-axis model for both stators and rotor or a three-phase model of the stator and a two-axis model of the rotor. This may be adequate under certain operating conditions such as steady-state or some symmetrical faults but for inverter-fed motors or generators feeding into a rectified load a more rigorous model of the machine is required. This paper describes the theory and development of such a model, its integration with the power electronics and application to 6-pulse and 12-pulse converters, the latter being appropriate in systems similar to HVDC unit connection. (author) 5 refs., 16 figs.

  19. A Proposal on Low Frequency AC Transmission as a Multi-Terminal Transmission System

    OpenAIRE

    Achara Pichetjamroen; Toshifumi Ise

    2016-01-01

    This paper is focused on the discussion and comparison of characteristics and behavior of three low frequency ac (LFAC) transmission system configurations operating under the same control scheme and conditions to identify the most promising operation system for LFAC. Merits of LFAC over high voltage direct current (HVDC) are mentioned first. By changing power flow direction without auxiliary switches in multi-terminal application and easiness of short circuit protection are explained. The thr...

  20. Small Signal Model for VSC-HVDC Connected DFIG-Based Offshore Wind Farms

    Directory of Open Access Journals (Sweden)

    Kai Liao

    2014-01-01

    Full Text Available Large-scale offshore wind farms are integrated with onshore ac grids through the voltage source converter based high voltage direct current (VSC-HVDC transmission system. The impact on the stability of the ac grids will be significant. The small signal model of a wind farm connected with voltage source converter based dc transmission system is studied in this paper. A suitable model for small signal stability analysis is presented. The control system of wind generator and the HVDC system has also been modeled in this model for small signal stability analysis. The impact of the control parameters on the network stability is investigated.

  1. Surge snubber design for high power-density DC-DC converters in HVDC power distribution systems

    OpenAIRE

    Domoto, Kazuhide; Ninomiya, Tamotsu; Ishizuka, Yoichi; Simanjorang, Rejeki; Yamaguchi, Hiroshi; Abe, Seiya; Kaga, Masato

    2012-01-01

    In an isolated DC-DC converter utilized in the HVDC power distribution system, a large surge voltage occurs across the secondary-side diodes due to the transformer's leakage inductance, and then the diodes with a large withstand voltage are required. However, those diodes cause a lot of power loss. In this paper, a simple surge snubber with prominent surge suppression capability is examined, and the surge-voltage evaluation through the analysis using the high-frequency equivalent circuits, wh...

  2. Decreasing the commutation failure frequency in HVDC transmission systems

    DEFF Research Database (Denmark)

    Hansen (retired June, 2000), Arne; Havemann (retired June, 2000), Henrik

    2000-01-01

    In this paper we show how a fairly large proportion of those commutation failures that are due to single-phased short circuits to earth can be avoided. In a control circuit based on a digital signal processor (DSP) it is possible, with instantaneous results, to switch from a normal control strategy...

  3. Application of VSC-HVDC with Shunt Connected SMES for Compensation of Power Fluctuation

    Science.gov (United States)

    Linn, Zarchi; Kakigano, Hiroaki; Miura, Yushi; Ise, Toshifumi

    This paper describes the application of VSC-HVDC (High Voltage DC Transmission using Voltage Source Converter) with shunt connected SMES (Superconducting Magnetic Energy Storage) for compensation of power fluctuation caused by fluctuating power source such as photovoltaics and wind turbines. The objectives of this proposed system is to smooth out fluctuating power in one terminal side of HVDC in order to avoid causing power system instability and frequency deviation by absorbing or providing power according to the system requirement while another terminal side power is fluctuated. The shunt connected SMES charges and discharges the energy to and from the dc side and it compensates required power of fluctuation to obtain constant power flow in one terminal side of VSC-HVDC system. This system configuration has ability for power system stabilization in the case of power fluctuation from natural energy source. PSCAD/EMTDC simulation is used to evaluate the performance of applied system configuration and control method.

  4. Direct current power delivery system and method

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Di; Garces, Luis Jose; Dai, Jian; Lai, Rixin

    2016-09-06

    A power transmission system includes a first unit for carrying out the steps of receiving high voltage direct current (HVDC) power from an HVDC power line, generating an alternating current (AC) component indicative of a status of the first unit, and adding the AC component to the HVDC power line. Further, the power transmission system includes a second unit for carrying out the steps of generating a direct current (DC) voltage to transfer the HVDC power on the HVDC power line, wherein the HVDC power line is coupled between the first unit and the second unit, detecting a presence or an absence of the added AC component in the HVDC power line, and determining the status of the first unit based on the added AC component.

  5. LCC based multiterminal HVDC for integration of large scale wind power

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Xiaobo; Yue, Changyan; Yao, Dawei [Corporate Research, ABB (China) Limited, Beijing (China)

    2011-07-01

    Multiterminal HVDC (MTDC) is becoming attractive for wind power transmission. Firstly, several large scale wind farm bases or wind farm clusters are possibly scattered in a vast area with abundant wind resources. Secondly, as the intermittence of wind power, it is preferable to transfer bulk wind power bundled with thermal power or hydro power to decrease the power fluctuation on the HVDC line while the bundled thermal power or hydro power may be far away from the wind power bases. Voltage source converter based multiterminal HVDC (VSC MTDC) has been identified as a preferable solution for wind power transmission as it provides more control flexibility benefited from forced commutation. However, the capacity of VSC HVDC today is still lower than that of a line commutated converter based MTDC (LCC MTDC). For large onshore scale wind farm clusters, LCC MTDC still provides an attractive solution. Generally speaking, LCC MTDC can be a parallel or series connection system. Both of these two systems are developed from point to point HVDC technology. By far only the concept with parallel converters has been used for its lower power losses and well developed technology. In this paper, based on the analysis of wind power development trend, the market prospection and application scenarios of LCC MTDC for wind application are presented. The selection criteria of LCC MTDC for wind application are introduced. (orig.)

  6. HVDC Ground Electrodes - a Source of Geophysical Data

    Science.gov (United States)

    Freire, P. F.; Pereira, S. Y.

    2015-12-01

    The HVDC electrode is a component of a High Voltage Direct Current energy transmission system, and is designed to inject into the ground continuous currents up to 3500 A. The typical HVDC ground electrode is a ring of vertical conductors, 1 km wide, buried a few tens of meters.The design of a HVDC electrode is based on extensive geological, geotechnical and geophysical surveys. Geophysical data are usually electrical (VES) and electromagnetic (TEM/MT) acquisitions, for the modeling of the shallow, near-surface and deep layers of the crust. This survey aims, first, the electrode site selection, and then, at the selected site, this data is combined into a single apparent resistivity curve, which is inverted, allowing for the determination of the layered geoelectric crust model. The injection of electrical continuous current in the electrode is then simulated, with the geoelectric crust model, for the determination of the soil surface potential profile (which is usually asymmetric for different directions, due to non-1D geoelectric models).For the commissioning of a HVDC electrode, field measurements are done, such as electrode grounding resistance, soil surface potentials and metal-to-soil potentials at specific structures (buried pipelines, for instance).The geophysical data acquired during the design phase is a set of data completely independent from the electrical data acquired during the electrode commissioning phase, and both are correlated by the geoelectric model. It happens, therefore, that the geoelectric model can be calibrated based on the electrical data, with the correction of static shifts and other adjustments.This paper suggests that the commissioning of HVDC systems should be associated to a research & development program, with a university or foundation. The idea is to enjoy the opportunity of a more complete field survey, with the acquisition of a wide set of data for a better geological characterization of the area where the electrode was built.

  7. Modeling of HVDC in Dynamic State Estimation Using Unscented Kalman Filter Method

    DEFF Research Database (Denmark)

    Khazraj, Hesam; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2016-01-01

    HVDC transmission is an integral part of various power system networks. This article presents an Unscented Kalman Filter dynamic state estimator algorithm that considers the presence of HVDC links. The AC - DC power flow analysis, which is implemented as power flow solver for Dynamic State...... Estimation (DSE), creates an updated admittance matrix. First, a hybrid AC/DC network model is developed to combine the AC network and DC links. Then a non-linear state estimator can solve for hybrid AC/DC states by applying the unscented Kalman filter (UKF) algorithm. It is demonstrated that UKF is easy...

  8. Field tests of Sub-Synchronous Oscillation damping and frequency controllers of the Rihand-Delhi HVDC bipole

    Energy Technology Data Exchange (ETDEWEB)

    Prasad, Mata [ABB, New Delhi (India); Rao, L.V.; Chakravorty, S.; Moni, R.S.; Dass, R. [National Thermal Power Corporation Ltd., New Delhi (India); Mishra, R.B.; Tripathi, D.B. [Powergrid (India); Bjorklund, Hans; Duchen, Hugo; Westling, Soren [ABB Power Systems, Ludvika (Sweden)

    1994-12-31

    The Rihand-Delhi Hvdc transmission system comprises of two poles in bipolar mode, each of 750 MW nominal capacity. The length of the transmission line is 814 km and the main objective of the link is the transmission of bulk power from the Singrauli/Rihand thermal generating complex to the major load centers near the National Capital region. As in all major Hvdc schemes, the Rihand-Delhi Hvdc project has also been provided with a SSO damping controller which was extensively tested in the simulator prior to installation. This paper describes some of the important field tests conducted to ascertain actual performance and compares the same with corresponding simulator cases. Also covered is the performance of the frequency controller. (author) 3 refs., 9 figs.

  9. Integral Plus Resonant Sliding Mode Direct Power Control for VSC-HVDC Systems under Unbalanced Grid Voltage Conditions

    Directory of Open Access Journals (Sweden)

    Weipeng Yang

    2017-10-01

    Full Text Available An integral plus resonant sliding mode direct power control (IRSMC DPC strategy for voltage source converter high voltage direct current (VSC-HVDC systems under unbalanced grid voltage conditions is proposed in this paper. Through detailed instantaneous power flow analysis, a generalized power compensation method, by which the ratio between the amplitude of active and reactive power ripples can be controlled continuously, is obtained. This enables the system to provide flexible power control, so that the desired performance of the system on both the ac and dc sides can be attained under different operating conditions. When the grid voltage is unbalanced, one or both of the active and reactive power terms contain ripples, oscillating at twice the grid frequency, to obtain non-distorted ac current. A power controller consisting of the proportional, integral and resonant control laws is designed using the sliding mode control approach, to achieve accurate power control objective. Simulation studies on a two-terminal VSC-HVDC system using MATLAB/SIMULINK (R2013b, Mathworks, Natick, MA, USA are conducted to verify the effectiveness of the IRSMC DPC strategy. The results show that this strategy ensures satisfactory performance of the system over a wide range of operating conditions.

  10. Site Selection for Hvdc Ground Electrodes

    Science.gov (United States)

    Freire, P. F.; Pereira, S. Y.

    2014-12-01

    High-Voltage Direct Current (HVDC) transmission systems are composed of a bipole transmission line with a converter substation at each end. Each substation may be equipped with a HVDC ground electrode, which is a wide area (up to 1 km Ø) and deep (from 3 to 100m) electrical grounding. When in normal operation, the ground electrode will dissipate in the soil the unbalance of the bipole (~1.5% of the rated current). When in monopolar operation with ground return, the HVDC electrode will inject in the soil the nominal pole continuous current, of about 2000 to 3000 Amperes, continuously for a period up to a few hours. HVDC ground electrodes site selection is a work based on extensive geophysical and geological surveys, in order to attend the desired design requirements established for the electrodes, considering both its operational conditions (maximum soil temperature, working life, local soil voltage gradients etc.) and the interference effects on the installations located up to 50 km away. This poster presents the geophysical investigations conducted primarily for the electrodes site selection, and subsequently for the development of the crust resistivity model, which will be used for the interference studies. A preliminary site selection is conducted, based on general geographical and geological criteria. Subsequently, the geology of each chosen area is surveyed in detail, by means of electromagnetic/electrical geophysical techniques, such as magnetotelluric (deep), TDEM (near-surface) and electroresistivity (shallow). Other complementary geologic and geotechnical surveys are conducted, such as wells drilling (for geotechnical characterization, measurement of the water table depth and water flow, and electromagnetic profiling), and soil and water sampling (for measurement of thermal parameters and evaluation of electrosmosis risk). The site evaluation is a dynamic process along the surveys, and some sites will be discarded. For the two or three final sites, the

  11. Modelisation et simulation d'une liaison HVDC de type VSC-MMC

    Science.gov (United States)

    Saad, Hani Aziz

    High-voltage direct current transmission systems (HVDC) are rapidly expanding in the world. Two main factors are responsible for this expansion. The first is related to the difficulty of building new overhead lines to ensure the development of high-voltage AC grids, which makes the usage of underground cables more common. However, the use of such cables is limited in length to a few tens of km because of the capacitive current generated by the cable itself. Beyond this length limit, the solution is usually to transmit in DC. The second factor is related to the development of offshore wind power plants that require connecting powers of several hundred of MW to the mainland grid by cables whose lengths can reach several hundreds of km and consequently require HVDC transmission system. Several HVDC projects are currently planned and developed by the French transmission system operator RTE. One of such projects is the INELFE interconnection project, with a capacity of 2,000 MW, between France and Spain. This thesis has been funded by RTE, in order to model and simulate in off-line and real time modes, modern HVDC interconnections. The delivered simulation means are used to examine targeted HVDC system performances and risks of abnormal interactions with surrounding power systems. The particularity of the INELFE HVDC system is the usage of a dedicated control system that will largely determine the dynamic behaviour of the system for both large disturbances (faults on the network) and small perturbations (power step changes). Various VSC topologies, including the conventional two-level, multi-level diode-clamped and floating capacitor multi-level converters, have been proposed and reported in the literature. However, due to the complexity of controls and practical limitations, the VSC-HVDC system installations have been limited to the two-level and three-level diode-clamped converters. Recently, the development of modular technology called MMC (Modular Multilevel

  12. A comparison of the technological, economic, public policy, and environmental factors of HVDC and HVAC interregional transmission

    Directory of Open Access Journals (Sweden)

    Armando L. Figueroa-Acevedo

    2015-02-01

    Full Text Available The design of an interregional high-voltage transmission system in the US is a revolutionary technological concept that will likely play a significant role in the planning and operation of future electric power systems. Historically, the primary justification for building interregional high-voltage transmission lines in the US and around the world has been based on economic and reliability criteria. Today, the implementation renewable portfolio standards, carbon emission regulations, the improvements in the performance of power electronic systems, and unused benefits associated with capacity exchange during times of non-coincident peak demand, are driving the idea of designing an interregional high-voltage transmission system in the US. However, there exist challenges related to technical, economic, public policy, and environmental factors that hinder the implementation of such a complex infrastructure. The natural skepticism from many sectors of the society, in regards to how will the system be operated, how much will it cost, and the environmental impact that it could potentially create are among the most significant challenges to its rapid implementation. This publication aims at illustrating the technological, environmental, economic, and policy challenges that interregional HV transmission systems face today in the US, looking specifically at the Clean Line Rock Island project in Iowa.

  13. Frequency Regulation Strategies in Grid Integrated Offshore Wind Turbines via VSC-HVDC Technology: A Review

    Directory of Open Access Journals (Sweden)

    Jafar Jallad

    2017-08-01

    Full Text Available The inclusion of wind energy in a power system network is currently seeing a significant increase. However, this inclusion has resulted in degradation of the inertia response, which in turn seriously affects the stability of the power system’s frequency. This problem can be solved by using an active power reserve to stabilize the frequency within an allowable limit in the event of a sudden load increment or the loss of generators. Active power reserves can be utilized via three approaches: (1 de-loading method (pitching or over-speeding by a variable speed wind turbine (VSWT; (2 stored energy in the capacitors of voltage source converter-high voltage direct current (VSC-HVDC transmission; and (3 coordination of frequency regulation between the offshore wind farms and the VSC-HVDC transmission. This paper reviews the solutions that can be used to overcome problems related to the frequency stability of grid- integrated offshore wind turbines. It also details the permanent magnet synchronous generator (PMSG with full-scale back to back (B2B converters, its corresponding control strategies, and a typical VSC-HVDC system with an associated control system. The control methods, both on the levels of a wind turbine and the VSC-HVDC system that participate in a system’s primary frequency control and emulation inertia, are discussed.

  14. Operation and control of a DC-grid offshore wind farm under DC transmission system faults

    DEFF Research Database (Denmark)

    Deng, Fujin; Chen, Zhe

    2013-01-01

    So far, all existing offshore wind farms have an ac collection system, and the collected power in the offshore wind farm is sent to an onshore ac grid through high-voltage ac (HVAC) or DC (HVDC) transmission lines. However, future of fshore wind farms may use dc also for power collection. Consequ......So far, all existing offshore wind farms have an ac collection system, and the collected power in the offshore wind farm is sent to an onshore ac grid through high-voltage ac (HVAC) or DC (HVDC) transmission lines. However, future of fshore wind farms may use dc also for power collection....... Consequently, the protection and control strategies of dc systems need to be established. This paper studies a dc-grid offshore wind farm, where the wind power collection system and power transmission system adopt dc technology. In this paper, the redundancy of the HVDC transmission system under faults...... is studied, and a fault ridethrough strategy for the dc-grid offshore wind farm is proposed. The proposed strategy can effectively minimize the impacts of the power transmission system disturbance on the offshore wind farm, and on the ac grid. A dc-grid offshore wind farm example is simulated with PSCAD...

  15. An Examination of AC/HVDC Power Circuits for Interconnecting Bulk Wind Generation with the Electric Grid

    Directory of Open Access Journals (Sweden)

    Daniel Ludois

    2010-06-01

    Full Text Available The application of high voltage dc (HVDC transmission for integrating large scale and/or off-shore wind generation systems with the electric grid is attractive in comparison to extra high voltage (EHV ac transmission due to a variety of reasons. While the technology of classical current sourced converters (CSC using thyristors is well established for realization of large HVDC systems, the technology of voltage sourced converters (VSC is emerging to be an alternative approach, particularly suitable for multi-terminal interconnections. More recently, a more modular scheme that may be termed ‘bridge of bridge’ converters (BoBC has been introduced to realize HVDC systems. While all these three approaches are functionally capable of realizing HVDC systems, the converter power circuit design trade-offs between these alternatives are not readily apparent. This paper presents an examination of these topologies from the point of view of power semiconductor requirements, reactive component requirements, operating losses, fault tolerance, multi-terminal operation, modularity, complexity, etc. Detailed analytical models will be used along with a benchmark application to develop a comparative evaluation of the alternatives that maybe used by wind energy/bulk transmission developers for performing engineering trade-off studies.

  16. Dynamic over-voltages in a multi in-feed HVDC system

    Energy Technology Data Exchange (ETDEWEB)

    Bruntt, M.

    1997-12-31

    In this report the dynamic over-voltages caused by blocking of one or more HVDC converters feeding into an AC network is analyzed. The voltage regulating capability of the nearby generators is one of the determining factors. The waveform of a typical overvoltage caused by simultaneous blocking of converters is analyzed. An index (effective short circuit ratio ESCR) characterizing the magnitude of the overvoltage from blocking of a single converter is already known. This index is extended to embody the overvoltage caused by the simultaneous blocking of two converters. Also expressions for the overvoltage caused by blocking of more than two converters in a simplified network configuration are derived. The overvoltage caused by simultaneous blocking of two or more converters appears to be characterized by the same index as for a single converter when the index is multiplied by a correction factor depending on the network impedances and the transmitted dc powers. The same expressions are modified to obtain the overvoltage at a bus where no converter is connected in case of blocking of one or more converters. (au)

  17. Review of the development of multi-terminal HVDC and DC power grid

    Science.gov (United States)

    Chen, Y. X.

    2017-11-01

    Traditional power equipment, power-grid structures, and operation technology are becoming increasingly powerless with the large-scale renewable energy access to the grid. Thus, we must adopt new technologies, new equipment, and new grid structure to satisfy future requirements in energy patterns. Accordingly, the multiterminal direct current (MTDC) transmission system is receiving increasing attention. This paper starts with a brief description of current developments in MTDC worldwide. The MTDC project, which has been placed into practical operation, is introduced by the Italian–Corsica–Sardinian three-terminal high-voltage DC (HVDC) project. We then describe the basic characteristics and regulations of multiterminal DC transmission. The current mainstream of several control methods are described. In the third chapter, the key to the development of MTDC system or hardware and software technology that restricts the development of multiterminal DC transmission is discussed. This chapter focuses on the comparison of double-ended HVDC and multiterminal HVDC in most aspects and subsequently elaborates the key and difficult point of MTDC development. Finally, this paper summarizes the prospect of a DC power grid. In a few decades, China can build a strong cross-strait AC-DC hybrid power grid.

  18. A novel modular multilevel converter modelling technique based on semi-analytical models for HVDC application

    Directory of Open Access Journals (Sweden)

    Ahmed Zama

    2016-12-01

    Full Text Available Thanks to scalability, performance and efficiency, the Modular Multilevel Converter (MMC, since its invention, becomes an attractive topology in industrial applications such as high voltage direct current (HVDC transmission system. However, modelling challenges related to the high number of switching elements in the MMC are highlighted when such systems are integrated into large simulated networks for stability or protection algorithms testing. In this work, a novel dynamic models for MMC is proposed. The proposed models are intended to simplify modeling challenges related to the high number of switching elements in the MMC. The models can be easily used to simulate the converter for stability analysis or protection algorithms for HVDC grids.

  19. Touch potential measurement on fences and pipings in the influence areas of the electrodes of the Itaipu HVDC system; Medicao de potencial de toque em cercas e tubulacoes nas areas de influencia dos eletrodos do sistema CCAT de Itaipu

    Energy Technology Data Exchange (ETDEWEB)

    Caroli, C.E.; Santos, N.; Nagoya, J.T.; Pereira, J.C.C. [FURNAS, Rio de Janeiro, RJ (Brazil); Kovarsky, D.; Marques, M.A.M.; Pinto, L.J.

    1987-12-31

    This work aims to evaluate the level of the interferences that would be caused by ground return current of the Itaipu HVDC system, and to indicate the previous providence of mitigation required in the affected installations 7 refs., 7 figs., 3 tabs.

  20. A Categorization of Converter Station Controllers Within Multi-terminal DC Transmission Systems

    DEFF Research Database (Denmark)

    Irnawan, Roni; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2016-01-01

    As more and more VSC-HVDC links are planned and commissioned, interconnection of neighboring links or connection to an existing link becomes a feasible step towards secure and reliable multi-terminal DC (MTDC) transmission systems. Multi-vendor MTDC (MV-MTDC) operation is anticipated as an impact...... of controller might exist in the same system. It is therefore important to identify the parameters required by the converter station controllers to ensure a smooth coordination. In this paper, different converter station controllers available in the literatures are categorized. Challenges of converter station...

  1. Grid-connection of large offshore windfarms utilizing VSC-HVDC: Modeling and grid impact

    DEFF Research Database (Denmark)

    Xue, Yijing; Akhmatov, Vladislav

    2009-01-01

    of this work on utilization of VSC-HVDC systems for grid connection of large offshore windfarms. In the investigation, a thermal power plant just south to the Danish border has been substituted by the 1,000 MW offshore windfarm with the VSC-HVDC system. The investigation has shown that the substitution...... in the North and Baltic Seas....

  2. A generic inertia emulation controller for multi-terminal VSC-HVDC systems

    DEFF Research Database (Denmark)

    Zhu, Jiebei; Guerrero, Josep M.; Booth, Campbell

    2013-01-01

    implementation to the conventional VSC control system are presented, and the impact of total DC capacitance of the MTDC network on DC voltage variations is discussed. The proposed INEC for MTDC systems are validated by Matlab/Simulink under demand changes in a simulated multi-machine power system with a MTDC...

  3. A Proposal on Low Frequency AC Transmission as a Multi-Terminal Transmission System

    Directory of Open Access Journals (Sweden)

    Achara Pichetjamroen

    2016-08-01

    Full Text Available This paper is focused on the discussion and comparison of characteristics and behavior of three low frequency ac (LFAC transmission system configurations operating under the same control scheme and conditions to identify the most promising operation system for LFAC. Merits of LFAC over high voltage direct current (HVDC are mentioned first. By changing power flow direction without auxiliary switches in multi-terminal application and easiness of short circuit protection are explained. The three configurations of LFACs are described and applied by the control scheme with the aid of the tool of the PSCAD/EMTDC software to consider the behavior of each LFAC system on line frequency and low frequency sides. For two-phase system, no fluctuation occurs on the line frequency side, which is the advantage over single-phase system. Furthermore, current rating on thyristor devices during operation and number of devices that used in each type of LFAC are calculated and compared. These results can lead to determine the most suitable transmission system for the LFAC system operation.

  4. Study on VSC HVDC Modeling and Control Strategies for Wind Power Integration

    DEFF Research Database (Denmark)

    Korompili, Asimenia; Wu, Qiuwei

    is performed, regarding power losses, costs, equipment aspects and control capabilities. It is concluded that the VSC-HVDC system exhibits the most advantageous features for the grid connection of offshore wind farms. In addition, various topologies of the HVDC converter stations are analysed. Furthermore...

  5. Coordination of protection system and VSC-HVDC to mitigate cascading failures

    OpenAIRE

    Leelaruji, Rujiroj

    2010-01-01

    The rapid development of the global economics has made power systems allover the world become large-scale interconnected grids. This increases the capabilityof power grids to transfer power over the long distance to serve the desiredpower demand with the minimum cost of operation. Unfortunately, it alsoenables the propagation of local failures into global networks. In other words,if a blackout happens in a power system, the size and the damage may significantlyincrease. One of the main ways i...

  6. Probabilistic transmission system planning

    CERN Document Server

    Li, Wenyuan

    2011-01-01

    "The book is composed of 12 chapters and three appendices, and can be divided into four parts. The first part includes Chapters 2 to 7, which discuss the concepts, models, methods and data in probabilistic transmission planning. The second part, Chapters 8 to 11, addresses four essential issues in probabilistic transmission planning applications using actual utility systems as examples. Chapter 12, as the third part, focuses on a special issue, i.e. how to deal with uncertainty of data in probabilistic transmission planning. The fourth part consists of three appendices, which provide the basic knowledge in mathematics for probabilistic planning. Please refer to the attached table of contents which is given in a very detailed manner"--

  7. Wireless data signal transmission system

    DEFF Research Database (Denmark)

    2014-01-01

    The present invention relates to a method for providing a radio frequency signal for transmission, a system for providing a radio frequency signal for transmission and a method for wireless data transmission between a transmitter and a receiver.......The present invention relates to a method for providing a radio frequency signal for transmission, a system for providing a radio frequency signal for transmission and a method for wireless data transmission between a transmitter and a receiver....

  8. A Novel Topology of Hybrid HVDC Circuit Breaker for VSC-HVDC Application

    Directory of Open Access Journals (Sweden)

    Van-Vinh Nguyen

    2017-10-01

    Full Text Available The use of high voltage direct current (HVDC circuit breakers (CBs with the capabilities of bidirectional fault interruption, reclosing, and rebreaking can improve the reliable and safe operation of HVDC grids. Although several topologies of CBs have been proposed to perform these capabilities, the limitation of these topologies is either high on-state losses or long time interruption in the case bidirectional fault current interruption. Long time interruption results in the large magnitude of the fault current in the voltage source converter based HVDC (VSC-HVDC system due to the high rate of rise of fault current. This paper proposes a new topology of hybrid CB (HCB with lower conduction loss and lower interruption time to solve the problems. The proposed topology is based on the inverse current injection method, which uses the capacitor to enforce the fault current to zero. In the case of the bidirectional fault current interruption, the capacitor does not change its polarity after identifying the direction of fault current, which can reduce the interruption time accordingly. A switching control algorithm for the proposed topology is presented in detail. Different operation modes of proposed HCB, such as normal current mode, breaking fault current mode, discharging, and reversing capacitor voltage modes after clearing the fault, are considered in the proposed algorithm. The proposed topology with the switching control algorithm is tested in a simulation-based system. Different simulation scenarios such as temporary and permanent faults are carried out to verify the performance of the proposed topology. The simulation is performed in the Matlab/Simulink environment.

  9. Transmission expansion simulation for the European Northern Seas offshore grid

    NARCIS (Netherlands)

    Gorenstein Dedecca, J.; Hakvoort, R.A.; Herder, P.M.

    2017-01-01

    HVDC innovations and the integration of power markets and renewables drive the development of a European Northern Seas offshore grid. This power transmission system performs two functions: interconnecting Northern European onshore power systems, and connecting offshore wind farms. Despite its

  10. A Combined Reliability Model of VSC-HVDC Connected Offshore Wind Farms Considering Wind Speed Correlation

    DEFF Research Database (Denmark)

    Guo, Yifei; Gao, Houlei; Wu, Qiuwei

    2017-01-01

    This paper proposes a combined reliability model of voltage source converter-based high voltage direct current (VSCHVDC) connected offshore wind farms (WFs) using the frequency and duration technique. Firstly, a two-dimensional multi-state WF model is developed considering wind speed variations......-HVDC system and wind speed correlation on the system reliability were analyzed. Sensitivity analyses were conducted to investigate the impact of repair time of the offshore VSC-HVDC system on system reliability....

  11. Definition and Classification of Terms for HVDC Networks

    DEFF Research Database (Denmark)

    Vrana, Til Kristian; Bell, Keith; Sørensen, Poul Ejnar

    2015-01-01

    classified in a systematic way. The motivation for this work has been to help to reduce the communication problems that are emerging when power system engineers talk to HVDC technology engineers. The main guidelines underpinning the approach taken here is to minimise conflicts with the mentioned two existing...

  12. The HVDC Supplementary Control for AC/DC Interconnected Power Grid Based on Hamilton Energy Function Theory

    National Research Council Canada - National Science Library

    Shi, Fang; Wang, Jie

    2014-01-01

    ... current (HVDC), power modulation control can be used to compensate the energy imbalance while improving transient angle stability of the power system [2]. On the other hand, the voltage maintenance capability supplied by the AC line can help HVDC links recovering from short-term commutation failures or single/bipolar blocking faults. For examp...

  13. Protection of Multiterminal HVDC Grids based on Modular Multilevel Converters: DC Fault Ride-Through and AC Grid Support

    OpenAIRE

    Kontos, E.

    2018-01-01

    High Voltage DC (HVDC) grids provide an efficient solution for the transmission of bulk power over long distances between the energy production and consumption centers. Up to now, most of the implemented dc connections are point-to-point, creating dc links to strengthen the existing, predominantly ac, electricity grid. However, to optimize the use of assets and energy harvest, multi-terminal HVdc grids are envisioned. Based on recent research and industrial trends, the Multilevel Modular Conv...

  14. Dynamic Performance of an HVDC Link

    Directory of Open Access Journals (Sweden)

    S. A. ZIDI

    2005-09-01

    Full Text Available This paper presents the results of a simulation study on a 12 pulse HVDC (High Voltage Direct Current using a system in Matlab/Simulink. The object of the study is to investigate the steady state and dynamic performance of the system. First we examine response of current regulator after change in current reference in order to see the behavior of the controllers in controlling the desired current. Next, we present the digital simulation of a test system and show the response to a DC fault in the line and the AC fault at inverter side. The results are evaluated to enhance the recovery of the system from the disturbances for a full range of typical disturbances. The presented approach benefits from Simulink’s advantages in modeling and simulating dynamical systems.

  15. Wind turbines and transmission systems for offshore wind projects in planning stage

    Energy Technology Data Exchange (ETDEWEB)

    Madariaga, Ander; Martin, Jose Luis; Martinez de Alegria, Inigo; Zamora, Inmaculada [University of the Basque Country (UPV/EHU), Bilbao (Spain). Engineering Faculty; Ceballos, Salvador [Parque Tecnologico de Bizkaia, Derio (Spain). Tecnalia Research and Innovation

    2012-07-01

    This paper reviews the current situation of the offshore wind turbines (OWTs) and the transmission systems (TSs) for offshore wind projects in the planning stage. Bearing in mind that offshore wind projects can last between seven and ten years from the first environmental studies to the commissioning, research engineers from companies and academia consider the solutions already available, but also to the new proposals expected to be ready in time for the project under consideration. Regarding the wind energy conversion systems (WECSs) installed in the OWTs, their main characteristics are reviewed considering turbines in the 4.1 to 10.0 MW range. Regarding the TSs, the current situation of point-to-point HVAC and HVDC links is presented, as well as some ideas related to future DC grids currently under study. (orig.)

  16. WSN-Based Space Charge Density Measurement System.

    Directory of Open Access Journals (Sweden)

    Dawei Deng

    Full Text Available It is generally acknowledged that high voltage direct current (HVDC transmission line endures the drawback of large area, because of which the utilization of cable for space charge density monitoring system is of inconvenience. Compared with the traditional communication network, wireless sensor network (WSN shows advantages in small volume, high flexibility and strong self-organization, thereby presenting great potential in solving the problem. Additionally, WSN is more suitable for the construction of distributed space charge density monitoring system as it has longer distance and higher mobility. A distributed wireless system is designed for collecting and monitoring the space charge density under HVDC transmission lines, which has been widely applied in both Chinese state grid HVDC test base and power transmission projects. Experimental results of the measuring system demonstrated its adaptability in the complex electromagnetic environment under the transmission lines and the ability in realizing accurate, flexible, and stable demands for the measurement of space charge density.

  17. WSN-Based Space Charge Density Measurement System.

    Science.gov (United States)

    Deng, Dawei; Yuan, Haiwen; Lv, Jianxun; Ju, Yong

    2017-01-01

    It is generally acknowledged that high voltage direct current (HVDC) transmission line endures the drawback of large area, because of which the utilization of cable for space charge density monitoring system is of inconvenience. Compared with the traditional communication network, wireless sensor network (WSN) shows advantages in small volume, high flexibility and strong self-organization, thereby presenting great potential in solving the problem. Additionally, WSN is more suitable for the construction of distributed space charge density monitoring system as it has longer distance and higher mobility. A distributed wireless system is designed for collecting and monitoring the space charge density under HVDC transmission lines, which has been widely applied in both Chinese state grid HVDC test base and power transmission projects. Experimental results of the measuring system demonstrated its adaptability in the complex electromagnetic environment under the transmission lines and the ability in realizing accurate, flexible, and stable demands for the measurement of space charge density.

  18. Hybrid-Vehicle Transmission System

    Science.gov (United States)

    Lupo, G.; Dotti, G.

    1985-01-01

    Continuously-variable transmission system for hybrid vehicles couples internal-combustion engine and electric motor section, either individually or in parallel, to power vehicle wheels during steering and braking.

  19. Harmonics in Offshore Wind Power Plants Employing Power Electronic Devices in the Transmission System

    DEFF Research Database (Denmark)

    Glasdam, Jakob Bærholm

    of wind power. The onshore as well as offshore wind power plants (OWPPs) therefore have to meet the same stringent requirement as the conventional power plants. This can be accommodated by employment of flexible alternating current transmission system (FACTS) devices, such as the static compensator...... approach. Previously, a detailed equivalent model of the MMCC VSC-HVDC has been devised based on the “Nested Fast and Simultaneous Solution” procedure. However, there are some limitations to the previous model as it is specifically intended for the MMCC employing half-bridge converters in the SMs....... The somewhat more complex structure of the full-bridge converter employed in the MMCC STATCOM makes it complex to apply the existing modelling approach for the STATCOM. A universal modelling technique is proposed, which is able to represent both the half- and full-bridge based SMs. The modelling technique...

  20. Topics in lightwave transmission systems

    CERN Document Server

    Li, Tingye

    1991-01-01

    Topics in Lightwave Transmission Systems is a second volume of a treatise on optical fiber communications that is devoted to the science, engineering, and application of information transmission via optical fibers. The first volume, published in 1985, dealt exclusively with fiber fabrication. The present volume contains topics that pertain to subsystems and systems. The book contains five chapters and begins with discussions of transmitters and receivers, which are basic to systems now operating in the field. Subsequent chapters cover topics relating to coherent systems: frequency and phase m

  1. Method and system for a gas tube-based current source high voltage direct current transmission system

    Energy Technology Data Exchange (ETDEWEB)

    She, Xu; Chokhawala, Rahul Shantilal; Bray, James William; Sommerer, Timothy John; Zhou, Rui; Zhang, Di

    2017-08-29

    A high-voltage direct-current (HVDC) transmission system includes an alternating current (AC) electrical source and a power converter channel that includes an AC-DC converter electrically coupled to the electrical source and a DC-AC inverter electrically coupled to the AC-DC converter. The AC-DC converter and the DC-AC inverter each include a plurality of legs that includes at least one switching device. The power converter channel further includes a commutating circuit communicatively coupled to one or more switching devices. The commutating circuit is configured to "switch on" one of the switching devices during a first portion of a cycle of the H-bridge switching circuits and "switch off" the switching device during a second portion of the cycle of the first and second H-bridge switching circuits.

  2. Method and system for a gas tube switch-based voltage source high voltage direct current transmission system

    Energy Technology Data Exchange (ETDEWEB)

    She, Xu; Chokhawala, Rahul Shantilal; Zhou, Rui; Zhang, Di; Sommerer, Timothy John; Bray, James William

    2016-12-13

    A voltage source converter based high-voltage direct-current (HVDC) transmission system includes a voltage source converter (VSC)-based power converter channel. The VSC-based power converter channel includes an AC-DC converter and a DC-AC inverter electrically coupled to the AC-DC converter. The AC-DC converter and a DC-AC inverter include at least one gas tube switching device coupled in electrical anti-parallel with a respective gas tube diode. The VSC-based power converter channel includes a commutating circuit communicatively coupled to one or more of the at least one gas tube switching devices. The commutating circuit is configured to "switch on" a respective one of the one or more gas tube switching devices during a first portion of an operational cycle and "switch off" the respective one of the one or more gas tube switching devices during a second portion of the operational cycle.

  3. Marine High Voltage Power Conditioning and Transmission System with Integrated Storage DE-EE0003640 Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Frank Hoffmann, PhD; Aspinall, Rik

    2012-12-10

    Design, Development, and test of the three-port power converter for marine hydrokinetic power transmission. Converter provides ports for AC/DC conversion of hydrokinetic power, battery storage, and a low voltage to high voltage DC port for HVDC transmission to shore. The report covers the design, development, implementation, and testing of a prototype built by PPS.

  4. Harmonics in transmission power systems

    DEFF Research Database (Denmark)

    Wiechowski, Wojciech Tomasz

    Some time ago, Energinet.dk, the Transmission System Operator of the 150 kV and 400 kV transmission network in Denmark, had experienced operational malfunctions of some of the measuring and protection equipment. Also an overloading of a harmonic filter has been reported, and therefore, a need...... to perform more detailed harmonic studies emerged. Since the transmission network has a complex structure and its impedance varies with frequency in a nonlinear fashion, such harmonic study would require a detailed computer model of the network. Consequently, a PhD project proposal titled "Harmonics......, provided that background harmonic distortion, and the network configuration, are not changing during the measurement. It is shown that switching of a shunt linear power system component can result in variation of the harmonic levels that can be measured and used to verify the harmonic model of the network...

  5. Power transmission in direct current. Future expectations for Colombia

    Energy Technology Data Exchange (ETDEWEB)

    Velasco, D. [Departamento de Ingenieria Electronica, Universidad Politecnica de Valencia, Camino de Vera S/N, C.P. 46022, Valencia (Spain); Trujillo, C.L. [Departamento de Ingenieria Electronica, Universidad Politecnica de Valencia, Camino de Vera S/N, C.P. 46022, Valencia (Spain); Departamento de Ingenieria Electronica, Universidad Distrital Francisco Jose de Caldas, Carrera 7 No 40-53 Piso 5, Bogota (Colombia); Pena, R.A. [Departamento de Ingenieria Electronica, Universidad Distrital Francisco Jose de Caldas, Carrera 7 No 40-53 Piso 5, Bogota (Colombia)

    2011-01-15

    DC transmission is important when there are problems of instability in AC systems, i.e. when energy is transported through long distance. This issue requires research centers and multinational companies' investments to solve it. One solution is the high voltage DC transmission or HVDC (high voltage direct current). Worldwide HVDC interconnections have helped to solve problems of instability and moreover to easily interconnect systems where voltage and frequency are not compatible. According to that, the aim of this paper is first to analyze the advantages and disadvantages of DC systems compared to AC systems, and then to show future trends in DC systems, as well as present the possible interaction with renewable energies and the convenience of considering the implementation of that technology in Colombia. (author)

  6. Review of fault diagnosis and fault-tolerant control for modular multilevel converter of HVDC

    DEFF Research Database (Denmark)

    Liu, Hui; Loh, Poh Chiang; Blaabjerg, Frede

    2013-01-01

    , several typical topologies of MMC-HVDC systems are presented. Then fault types such as capacitor voltage unbalance, unbalance between upper and lower arm voltage are analyzed and the corresponding fault detection and diagnosis approaches are explained. In addition, more attention is dedicated to control......This review focuses on faults in Modular Multilevel Converter (MMC) for use in high voltage direct current (HVDC) systems by analyzing the vulnerable spots and failure mechanism from device to system and illustrating the control & protection methods under failure condition. At the beginning...... strategies, when running in MMC faults or grid faults. This paper ends up with a discussion of other opportunities for future development....

  7. Evaluation of half-bridge modular multilevel converter model for VSC-HVDC transient stability studies

    DEFF Research Database (Denmark)

    Irnawan, Roni; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2017-01-01

    This paper evaluates the modeling methods for a half-bridge modular multilevel converter (HB-MMC) based voltage-sourced converter (VSC) HVDC system for electromechanical transient (RMS) program. At first, the electrical and control system representation of the HB-MMC system in RMS program...

  8. Fault Ride-Through Capability Enhancement of VSC HVDC connected Offshore Wind Power Plants

    DEFF Research Database (Denmark)

    Sharma, Ranjan; Wu, Qiuwei; Cha, Seung-Tae

    2015-01-01

    This paper presents a feed forward direct current (DC) voltage control based fault ride-through (FRT) scheme for voltage source converter (VSC) high voltage DC (HVDC) connected offshore wind power plants (WPPs) in order to achieve active control of the WPP collector network AC voltage magnitude......, and to improve the FRT capability. During steady state operation, an open loop AC voltage control is implemented at the WPP side VSC of the HVDC system such that any possible control interactions between the WPP side VSC and the wind turbine VSC are minimized. Whereas during any grid faults, a dynamic AC voltage...

  9. Transmission system planning in Ontario

    Energy Technology Data Exchange (ETDEWEB)

    Barrie, D.; Macedo, F.X.; Mcconnach, J.S. [Ontario Hydro, Toronto, ON (Canada)

    1994-12-31

    In recent years, new and modified approaches to planning the large transmission system that serves the province of Ontario, Canada, have been necessary to accommodate the rapidly changing planning environment including slower uncertain growth, ageing of facilities, integration of demand side management and non utility generation options, increased competitiveness, increased financial stresses and affordable constraints. This paper describes some of the new and modified approaches and tools that have been adopted or are being developed by Ontario Hydro to cope with this changing environment. (author) 9 refs., 4 figs.

  10. Overvoltage and Insulation Coordination of Overhead Lines in Multiple-Terminal MMC-HVDC Link for Wind Power Delivery

    OpenAIRE

    He, Huiwen; Wang, Lei; Zhou, Peihong; Yan, Fei

    2017-01-01

    The voltage-sourced converter-based HVDC link, including the modular multilevel converter (MMC) configuration, is suitable for wind power, photovoltaic energy, and other kinds of new energy delivery and grid-connection. Current studies are focused on the MMC principles and controls and few studies have been done on the overvoltage of transmission line for the MMC-HVDC link. The main reason is that environmental factors have little effect on DC cables and the single-phase/pole fault rate is lo...

  11. Protection of Multiterminal HVDC Grids based on Modular Multilevel Converters : DC Fault Ride-Through and AC Grid Support

    NARCIS (Netherlands)

    Kontos, E.

    2018-01-01

    High Voltage DC (HVDC) grids provide an efficient solution for the transmission of bulk power over long distances between the energy production and consumption centers. Up to now, most of the implemented dc connections are point-to-point, creating dc links to strengthen the existing, predominantly

  12. Subsynchronous Torsional Interaction of Wind Farms with FSIG Wind Turbines Connected to LCC-HVDC Lines

    Directory of Open Access Journals (Sweden)

    Benfeng Gao

    2017-09-01

    Full Text Available High-voltage direct current (HVDC lines with line-commutated converter (LCC are being increasingly employed to transmit bulk wind power over long distance. However, this may cause the sub-synchronous torsional interaction (SSTI between the wind farms and the LCC-HVDC system. The SSTI characteristics of wind farms with fixed-speed induction generator (FSIG wind turbines connected to LCC-HVDC are investigated in this paper. To simplify the calculations, a modular modeling method is proposed for building the small-signal mathematical model of the investigated system. Small-signal analysis, participation factor analysis, and impact of dominant factors analysis are then applied to investigate the SSTI characteristics under different operating conditions. Three oscillation modes associated with the SSTI are identified in the entire system through small-signal and participation factor analysis, comprising two torsional modes and an electromechanical mode. Impact of dominant factors analysis shows that the system becomes less stable as the wind farm capacity grows and the distance between FSIG wind farm and the rectifier station increases. Moreover, the above analysis suggests that wind farms with FSIG connected to LCC-HVDC lines may not cause unstable SSTI. The electromagnetic transient simulations based on PSCAD/EMTDC (Power Systems Computer-Aided Design/Electromagnetic Transients including DC verify these results.

  13. Coordination Control Strategy for Compound Fault of MMC-HVDC

    Directory of Open Access Journals (Sweden)

    Zhang Ming Guang

    2016-01-01

    Full Text Available Single-line to ground fault of DC side and sub-module fault are typical faults of MMC-HVDC. When each of the above faults occurs, the system will give a signal for circuit-breaker releasing, this will result in interruption of power delivery, the stability of the system is greatly reduced. When these two faults occur simultaneously, research on control strategy for compound fault will help to improve the reliability of the system. While single-line to ground fault of DC side happens, only the electric potential auxiliary point of DC side is changed, system’s power transport normally. When sub-module is fault, redundancy fault-tolerated control strategy is presented, which replace the failed sub-modules with equal number of redundant sub-modules, it can restrain the fluctuation of direct current. A double terminals and 21 voltage-level MMC-HVDC system simulation model is set up in PSCAD/EMTDC. From the computation and simulation results, it is concluded that the proposed control strategy is correct for above compound fault, it can achieve rapid recovery after faults, effectively improve fault tolerance of the system, develop the stability and reliability of the system.

  14. Modelling and Simulation of VSC-HVDC Connection for Wind Power Plants

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay Kumar; Teodorescu, Remus; Rodriguez, Pedro

    2009-01-01

    step-up transformers. VSC's are modelled using ideal IGBT switches supplied by the gate pulses from their respective controllers. A sequence of operation has been simulated from the starting up of the VSC-HVDC transmission, energizing the offshore grid and subsequent synchronization of the individual...... wind turbines. Simulation of power ramping up and down as well as steady state operation has been demonstrated. As an additional case, the primary reserve control logic has been implemented and simulated in PSCAD model....

  15. Present trends in HVDC converter station design

    Energy Technology Data Exchange (ETDEWEB)

    Carlsson, Lennart; Asplund, Gunnar; Bjorklund, Hans; Flisberg, Gunnar [ABB Power Systems AB, Ludvika (Sweden)

    1994-12-31

    HVDC converter station technology has developed rapidly to satisfy increasing requirements during past 10 - 15 years, but there has not been any dramatic changes since thyristor valves were introduced in the mid 70s. This paper describes some recent and expected future developments, that will substantiality change and simplify future converter stations. (author) 4 refs., 7 figs.

  16. Lifetime Estimation of MMC for Offshore Wind Power HVDC Application

    DEFF Research Database (Denmark)

    Liu, Hui; Ma, Ke; Qin, Zian

    2016-01-01

    Due to a series of unique merits, Modular Multilevel Converters (MMCs) have been developing dramatically in the last decade. However in some applications like offshore power transmission the MMC modules are subjected to a variety of tough temperature profiles with adverse working condition, all...... of these could lead to thermomechanical fatigues in the components and joints of the power modules and thereby causing reliability challenge. This study focuses on the lifetime evaluation of MMC based on power cycling and thermal cycling considering the mission profiles in the High Voltage Direct Current (HVDC......) application for offshore wind power. The mission profiles as well as the topology of the MMC are first analyzed in order to better understand the loading characteristics of MMC. Then the power loss calculation along with the electro-thermal simulation is conducted to uncover the thermal loading of MMC...

  17. Lifetime Estimation of MMC for Offshore Wind Power HVDC Application

    DEFF Research Database (Denmark)

    Liu, Hui; Ma, Ke; Loh, Poh Chiang

    2014-01-01

    Due to a series of unique merits, Modular Multilevel Converters (MMCs) have been developing dramatically in the last decade. However in some applications like offshore power transmission the MMC modules are subjected to a variety of tough temperature profiles with adverse working condition, all...... of these could lead to thermo-mechanical fatigues in the components and joints of the power modules and thereby causing reliability challenge. This study focuses on the lifetime evaluation of MMC based on power cycling and thermal cycling considering the mission profiles in the High Voltage Direct Current (HVDC......) application for offshore wind power. The mission profiles as well as the topology of the MMC are first analyzed in order to better understand the loading profiles of MMC. Then the power loss calculation along with the electro-thermal simulation is conducted to uncover the thermal loading of MMC. At last...

  18. Dynamic modelling of VSC-HVDC for connection of offshore wind farms

    DEFF Research Database (Denmark)

    Rios, Bardo; Garcia-Valle, Rodrigo

    2011-01-01

    A VSC-HVDC (Voltage Source Converter – High Voltage Direct Current) dynamic model with a set of control strategies is developed in DIgSILENT Power-Factory with the objective of analyzing the converter’s operating capability for grid support during grid faults. The investigation is carried out based...... on a 165 MW offshore wind farm with induction generators and a Low Voltage Ride-Through solution of the offshore wind turbines and Static Voltage Compensator units in the point of connection with a grid represented by a reduced four-generator power grid model. VSC-HVDC promises to be a reliable alternative...... solution for interconnection with off-shore wind farms as they become larger, with a higher installed power capacity, increased number of wind turbines, and geographically situated at larger distances from suitable connection points in the transmission grids....

  19. Adaptive Modulation for DFIG and STATCOM With High-Voltage Direct Current Transmission.

    Science.gov (United States)

    Tang, Yufei; He, Haibo; Ni, Zhen; Wen, Jinyu; Huang, Tingwen

    2016-08-01

    This paper develops an adaptive modulation approach for power system control based on the approximate/adaptive dynamic programming method, namely, the goal representation heuristic dynamic programming (GrHDP). In particular, we focus on the fault recovery problem of a doubly fed induction generator (DFIG)-based wind farm and a static synchronous compensator (STATCOM) with high-voltage direct current (HVDC) transmission. In this design, the online GrHDP-based controller provides three adaptive supplementary control signals to the DFIG controller, STATCOM controller, and HVDC rectifier controller, respectively. The mechanism is to observe the system states and their derivatives and then provides supplementary control to the plant according to the utility function. With the GrHDP design, the controller can adaptively develop an internal goal representation signal according to the observed power system states, therefore, to achieve more effective learning and modulating. Our control approach is validated on a wind power integrated benchmark system with two areas connected by HVDC transmission lines. Compared with the classical direct HDP and proportional integral control, our GrHDP approach demonstrates the improved transient stability under system faults. Moreover, experiments under different system operating conditions with signal transmission delays are also carried out to further verify the effectiveness and robustness of the proposed approach.

  20. Variable Frequency Operations of an Offshore Wind Power Plant with HVDC-VSC: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Gevorgian, V.; Singh, M.; Muljadi, E.

    2011-12-01

    In this paper, a constant Volt/Hz operation applied to the Type 1 wind turbine generator. Various control aspects of Type 1 generators at the plant level and at the turbine level will be investigated. Based on DOE study, wind power generation may reach 330 GW by 2030 at the level of penetration of 20% of the total energy production. From this amount of wind power, 54 GW of wind power will be generated at offshore wind power plants. The deployment of offshore wind power plants requires power transmission from the plant to the load center inland. Since this power transmission requires submarine cable, there is a need to use High-Voltage Direct Current (HVDC) transmission. Otherwise, if the power is transmitted via alternating current, the reactive power generated by the cable capacitance may cause an excessive over voltage in the middle of the transmission distance which requires unnecessary oversized cable voltage breakdown capability. The use of HVDC is usually required for transmission distance longer than 50 kilometers of submarine cables to be economical. The use of HVDC brings another advantage; it is capable of operating at variable frequency. The inland substation will be operated to 60 Hz synched with the grid, the offshore substation can be operated at variable frequency, thus allowing the wind power plant to be operated at constant Volt/Hz. In this paper, a constant Volt/Hz operation applied to the Type 1 wind turbine generator. Various control aspects of Type 1 generators at the plant level and at the turbine level will be investigated.

  1. Power Hardware In The Loop Validation of Fault Ride Through of VSC HVDC Connected Offshore Wind Power Plants

    DEFF Research Database (Denmark)

    Sharma, Ranjan; Wu, Qiuwei; Cha, Seung-Tae

    2014-01-01

    This paper presents the power hardware in the loop (PHIL) validation of a feed forward DC voltage control scheme for the fault ride through (FTR) of voltage source converter (VSC) high voltage DC (HVDC) connected offshore wind power plants (WPPs). In the proposed FRT scheme, the WPP collector...... network AC voltage is actively controlled by considering both the DC voltage error and the AC current from the WPP AC collector system which ensures fast and robust FRT of the VSC HVDC connected offshore WPPs. The PHIL tests were carried out in order to verify the efficacy of the proposed feed forward DC...

  2. Overvoltage and Insulation Coordination of Overhead Lines in Multiple-Terminal MMC-HVDC Link for Wind Power Delivery

    Directory of Open Access Journals (Sweden)

    Huiwen He

    2017-01-01

    Full Text Available The voltage-sourced converter-based HVDC link, including the modular multilevel converter (MMC configuration, is suitable for wind power, photovoltaic energy, and other kinds of new energy delivery and grid-connection. Current studies are focused on the MMC principles and controls and few studies have been done on the overvoltage of transmission line for the MMC-HVDC link. The main reason is that environmental factors have little effect on DC cables and the single-phase/pole fault rate is low. But if the cables were replaced by the overhead lines, although the construction cost of the project would be greatly reduced, the single-pole ground fault rate would be much higher. This paper analyzed the main overvoltage types in multiple-terminal MMC-HVDC network which transmit electric power by overhead lines. Based on ±500 kV multiple-terminal MMC-HVDC for wind power delivery project, the transient simulation model was built and the overvoltage types mentioned above were studied. The results showed that the most serious overvoltage was on the healthy adjacent line of the faulty line caused by the fault clearing of DC breaker. Then the insulation coordination for overhead lines was conducted according to the overvoltage level. The recommended clearance values were given.

  3. Multi-core fiber undersea transmission systems

    DEFF Research Database (Denmark)

    Nooruzzaman, Md; Morioka, Toshio

    2017-01-01

    Various potential architectures of branching units for multi-core fiber undersea transmission systems are presented. It is also investigated how different architectures of branching unit influence the number of fibers and those of inline components....

  4. Offshore windfarm connection with low frequency AC transmission technology

    DEFF Research Database (Denmark)

    Qin, Nan; Xu, Zhao; You, Shi

    2009-01-01

    developed, which consists of three parts, the fixed-speed wind turbine representing a wind farm, the transmission line and the frequency converter. Although the transmission capability is greatly improved by the LFAC system, simulation shows it gives negative influences on the wind turbine operation due......This paper investigates the feasibility of using the low frequency AC transmission (LFAC) system, e.g. fraction of 50 Hz or 60 Hz, for connecting the large offshore wind farm to the grid by modelling and simulation. The LFAC system improves the transmission capacity and distance compared...... to the conventional AC solution at the nominal frequency, e.g. 50 Hz or 60 Hz. and reduces the investment cost compared to the HVDC solution. It is estimated that the LFAC system is competitive in the transmission distance of about 30-150 km. The simulation model of the wind integration using the LFAC system has been...

  5. 40 Gb/s optical transmission systems

    DEFF Research Database (Denmark)

    Buxens Azcoaga, Alvaro Juan; Nielsen, Steen Krogh

    2003-01-01

    This thesis investigates state of the art components and subsystems to be used in the next generation of high speed optical transmission systems at 40 Gb/s. The thesis will provide guidelines for the design and implementation of 40 Gb/s systems, investigating topics that could limit transmission......) experimental demonstrations are presented. The first one is a 100 GHz spaced 16 channel WDM system, using 40 Gb/s NRZ modulation over a 200 km link of standard-SMF. The second one is a 100 GHz spaced 32 channel 40 Gb/s WDM system, using CSRZ modulation over a 400 km link of standard-SMF and using Raman...

  6. Transients in VSC-HVDC connected offshore wind power plant

    DEFF Research Database (Denmark)

    El-Khatib, Walid Ziad; Schwartzberg, D.; Arana Aristi, I.

    2015-01-01

    The focus of this paper is transient phenomena in VSC-HVDC connected offshore wind power plants (WPPs). With the help of a case study modelled in PSCAD simulation software, energisation events are analysed in the time domain. A comparison with more well-known results obtained at energisation of AC...... connected WPPs indicates that significant differences arise as the energy involved in the switching event increases, due to the presence of the HVDC converter control. The influence of the offshore HVDC converter control gain in the most critical cases is assessed empirically and explained qualitatively....

  7. Study on electrochemical corrosion mechanism of steel foot of insulators for HVDC lines

    Science.gov (United States)

    Zheng, Weihua; Sun, Xiaoyu; Fan, Youping

    2017-09-01

    The main content of this paper is the mechanism of electrochemical corrosion of insulator steel foot in HVDC transmission line, and summarizes five commonly used artificial electrochemical corrosion accelerated test methods in the world. Various methods are analyzed and compared, and the simulation test of electrochemical corrosion of insulator steel feet is carried out by water jet method. The experimental results show that the experimental environment simulated by water jet method is close to the real environment. And the three suspension modes of insulators in the actual operation, the most serious corrosion of the V type suspension hardware, followed by the tension string suspension, and the linear string corrosion rate is the slowest.

  8. 47 CFR 73.6023 - Distributed transmission systems.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Distributed transmission systems. 73.6023... distributed transmission system. ... RADIO BROADCAST SERVICES Class A Television Broadcast Stations § 73.6023 Distributed transmission...

  9. Highly efficient solutions for smart and bulk power transmission of 'green energy'

    Energy Technology Data Exchange (ETDEWEB)

    Breuer, Wilfried; Retzmann, Dietmar; Uecker, Karl

    2010-09-15

    Environmental constraints, loss minimization and CO2 reduction will play an increasingly more important role in future. Security and sustainability of power supply as well as economic efficiency needs application of advanced technologies. Innovative solutions with HVDC (High Voltage Direct Current) and FACTS (Flexible AC Transmission Systems) have the potential to cope with these challenges. They provide the features which are necessary to avoid technical problems in power systems, they increase the transmission capacity and system stability very efficiently and help prevent cascading outages. Furthermore, they are essential for Grid Access of Renewable Energy Sources such as Hydro, Wind and Solar-Energy.

  10. Unidirectional Protection Strategy for Multi-terminal HVDC Grids

    Directory of Open Access Journals (Sweden)

    Ataollah Mokhberdoran

    2016-11-01

    Full Text Available Protection issue is identified as the main drawback of emerging multi-terminal HVDC grids. Multi-terminal HVDC grid demands fast short circuit fault current interruption. Fast DC circuit breakers as a promising solution can be implemented as either bidirectional or unidirectional devices. In addition to less implementation cost, the unidirectional DC circuit breakers have less power losses as compared to the bidirectional devices. A protection strategy for multi-terminal HVDC grid based on unidirectional breaking devices is discussed and assessed in this paper. The performance of unidirectional protection strategy is examined under different fault scenarios in a fourterminal MMC-HVDC grid model. Furthermore, the impacts of unidirectional protection strategy on power converters and also current interruption and surge arrester ratings of the DC circuit breakers are discussed.

  11. Benchmarking European Gas Transmission System Operators

    DEFF Research Database (Denmark)

    Agrell, Per J.; Bogetoft, Peter; Trinkner, Urs

    This is the final report for the pan-European efficiency benchmarking of gas transmission system operations commissioned by the Netherlands Authority for Consumers and Markets (ACM), Den Haag, on behalf of the Council of European Energy Regulators (CEER) under the supervision of the authors....

  12. International Benchmarking of Electricity Transmission System Operators

    DEFF Research Database (Denmark)

    Agrell, Per J.; Bogetoft, Peter

    2014-01-01

    Electricity transmission system operators (TSO) in Europe are increasing subject to high-powered performance-based regulation, such as revenue-cap regimes. The determination of the parameters in such regimes is challenging for national regulatory authorities (NRA), since there is normally a single...

  13. Transmission Quality Measurements in DAB+ Broadcast System

    Directory of Open Access Journals (Sweden)

    Gilski Przemysław

    2017-12-01

    Full Text Available In the age of digital media, delivering broadcast content to customers at an acceptable level of quality is one of the most challenging tasks. The most important factor is the efficient use of available resources, including bandwidth. An appropriate way of managing the digital multiplex is essential for both the economic and technical issues. In this paper we describe transmission quality measurements in the DAB+ broadcast system. We provide a methodology for analysing parameters and factors related with the efficiency and reliability of a digital radio link. We describe a laboratory stand that can be used for transmission quality assessment on a regional and national level.

  14. Models and methods for assessing the value of HVDC and MVDC technologies in modern power grids

    Energy Technology Data Exchange (ETDEWEB)

    Makarov, Yuri V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Elizondo, Marcelo A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); O' Brien, James G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Huang, Qiuhua [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kirkham, Harold [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Huang, Zhenyu [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chinthavali, Madhu [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Suman, Debnath [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Mohan, Nihal [Mid-Continent Independent System Operator (MISO), St. Paul, MN (United States); Hess, Warren [Mid-Continent Independent System Operator (MISO), St. Paul, MN (United States); Duebner, David [Mid-Continent Independent System Operator (MISO), St. Paul, MN (United States); Orser, David [Mid-Continent Independent System Operator (MISO), St. Paul, MN (United States); Brown, Hilary [Mid-Continent Independent System Operator (MISO), St. Paul, MN (United States); Osborn, Dale [Mid-Continent Independent System Operator (MISO), St. Paul, MN (United States); Feltes, James [Siemens, Knoxville, TN (United States); Kurthakoti Chandrashekhara, Divya [Siemens, Knoxville, TN (United States); Zhu, Wenchun [Siemens, Knoxville, TN (United States)

    2017-07-31

    This report reflects the results of U.S. Department of Energy’s (DOE) Grid Modernization project 0074 “Models and methods for assessing the value of HVDC [high-voltage direct current] and MTDC [multi-terminal direct current] technologies in modern power grids.” The work was done by the Pacific Northwest National Laboratory (PNNL) and Oak Ridge National Laboratory (ORNL) in cooperation with Mid-Continent Independent System Operator (MISO) and Siemens. The main motivation of this study was to show the benefit of using direct current (DC) systems larger than those in existence today as they overlap with the alternating current (AC) systems. Proper use of their flexibility in terms of active/reactive power control and fast response can provide much-needed services to the grid at the same time as moving large blocks of energy to take advantage of cost diversity. Ultimately, the project’s success will enable decision-makers and investors to make well-informed decisions regarding this use of DC systems. This project showed the technical feasibility of HVDC macrogrid for frequency control and congestion relief in addition to bulk power transfers. Industry-established models for commonly used technologies were employed, along with high-fidelity models for recently developed HVDC converter technologies; like the modular multilevel converters (MMCs), a voltage source converters (VSC). Models for General Electric Positive Sequence Load Flow (GE PSLF) and Siemens Power System Simulator (PSS/E), widely used analysis programs, were for the first time adapted to include at the same time both Western Electricity Coordinating Council (WECC) and Eastern Interconnection (EI), the two largest North American interconnections. The high-fidelity models and their control were developed in detail for MMC system and extended to HVDC systems in point-to-point and in three-node multi-terminal configurations. Using a continental-level mixed AC-DC grid model, and using a HVDC macrogrid

  15. Single transmission line data acquisition system

    Science.gov (United States)

    Fasching, George E.

    1984-01-01

    A single transmission line interrogated multiple channel data acquisition system is provided in which a plurality of remote station/sensors monitor specific process variables and transmit measurement values over the single transmission line to a master station when addressed by the master station. Power for all remote stations (up to 980) is provided by driving the line with constant voltage supplied from the master station and automatically maintained independent of the number of remote stations directly connected to the line. The transmission line can be an RG-62 coaxial cable with lengths up to about 10,000 feet with branches up to 500 feet. The remote stations can be attached randomly along the line. The remote stations can be scanned at rates up to 980 channels/second.

  16. Data transmission system with distributed microprocessors

    Science.gov (United States)

    Nambu, Shigeo

    1985-01-01

    A data transmission system having a common request line and a special request line in addition to a transmission line. The special request line has priority over the common request line. A plurality of node stations are multi-drop connected to the transmission line. Among the node stations, a supervising station is connected to the special request line and takes precedence over other slave stations to become a master station. The master station collects data from the slave stations. The station connected to the common request line can assign a master control function to any station requesting to be assigned the master control function within a short period of time. Each station has an auto response control circuit. The master station automatically collects data by the auto response controlling circuit independently of the microprocessors of the slave stations.

  17. Cote d'Ivoire satellite transmission system

    Science.gov (United States)

    Geiling, J. I.; Rasmussen, K. E.

    The Cote d'Ivoire (Ivory Coast) initiated a rural telecommunications study to analyze its national telecommunications network and to make recommendations for future growth and expansion. The study analyzed voice and data communications capabilities and requirements together with distribution and radio programming through the Cote d'Ivoire. Transmission alternatives were then investigated, and the optimum system configuration was defined. Concurrent with the study, a pilot system was installed using SCPC and DAMA transmission techniques; the system consisted of 60 voice channels for use with the public network and 12 executive channels for use with PABX and FX lines. This paper presents the results of the study, the verification of the study recommendations with the pilot system, and the future plans for the expansion of the network through the Cote d'Ivoire.

  18. Wind Resource Parameters Acquisition and Transmission System

    Directory of Open Access Journals (Sweden)

    ZHOU Xiao-Min

    2014-01-01

    Full Text Available Wind power generation is more mature and has good prospects for commercial development in the field of new energy technology. The wind parameters such as wind speed, wind direction, temperature, humidity, barometric pressure are required stably in the process of preliminary construction and operation of wind farms. This paper describes a set of wind measure system which achieves real-time data acquisition, storage and transmission reliably. The whole measure system consists of the core module, GPRS remote module, interface module and other components, in which the GPRS remote transmission module is accomplished through email attachments based on SMTP protocol. In the prototype test, the system operates accurately and reliably according to the analysis on the returned data. In addition, this paper processes the raw data for characteristic parameters with statistical methods, on the basis of which it simply sums up the characteristics of wind resource.

  19. Signal transmission system classification for intrusion detection systems

    Energy Technology Data Exchange (ETDEWEB)

    Blacksten, R.; Barnard, R.

    1985-01-01

    In this paper, the authors discuss the classification of signal transmission system security for modern intrusion detection systems. The content of this paper is based largely on a recent study conducted by the McLean Research Center for the US Army Belvoir R and D Center. This paper has a three-part message. First, the signal transmission component of a modern intrusion detection system is an important point of hostile attack and deserves comprehensive, carefully thought-out classification procedures. However, such classification is not an easy endeavor. Second, the signal transmission system is subject to several kinds of attack, complementing different attacker operations and goals. Third, a classification system focusing on the attacker -- his skill and resources -- is needed for intelligent decision making in security system integration and design. A good place to start this is with the signal transmission system.

  20. Transmission techniques for 4G systems

    CERN Document Server

    Da Silva, Mario Marques

    2012-01-01

    Fourth Generation (4G) wireless communication systems support current and emergent multimedia services such as mobile TV, social networks and gaming, high-definition TV, video teleconferencing, and messaging services. These systems feature the All-over-IP concept and boast improved quality of service. Several important R&D activities are currently under way in the field of wireless communications for 4G systems, but the coverage is widespread in the literature. Transmission Techniques for 4G Systems presents a compilation of the latest developments in the field of wireless communications for 4

  1. Steady-state and transient performance of HVDC link based 3-level ...

    African Journals Online (AJOL)

    Steady-state and transient performance of HVDC link based 3-level VSC supplying a passive load. ... The transient performance is explored by examining the VSC_HVDC response to external AC faults. Finally, the models ... Keywords: HVDC- voltage source converter (VSC) - IGBT- SPWM- Control design - passive load.

  2. ATTITUDE DETERMINATION AND DATA TRANSMISSION SYSTEMS FOR SPACE VEHICLES.

    Science.gov (United States)

    SPACECRAFT, *TELEMETER SYSTEMS), DATA TRANSMISSION SYSTEMS , SOUNDING ROCKETS, BALLOONS, SATELLITE TRACKING SYSTEMS, DATA STORAGE SYSTEMS, SOLAR RADIATION, RADIOMETERS, ULTRAHIGH FREQUENCY, FLIGHT TESTING

  3. Switching in electrical transmission and distribution systems

    CERN Document Server

    Smeets, René; Kapetanovic, Mirsad; Peelo, David F; Janssen, Anton

    2014-01-01

    Switching in Electrical Transmission and Distribution Systems presents the issues and technological solutions associated with switching in power systems, from medium to ultra-high voltage. The book systematically discusses the electrical aspects of switching, details the way load and fault currents are interrupted, the impact of fault currents, and compares switching equipment in particular circuit-breakers. The authors also explain all examples of practical switching phenomena by examining real measurements from switching tests. Other highlights include: up to date commentary on new develo

  4. Flexible AC transmission systems modelling and control

    CERN Document Server

    Zhang, Xiao-Ping; Pal, Bikash

    2012-01-01

    The extended and revised second edition of this successful monograph presents advanced modeling, analysis and control techniques of Flexible AC Transmission Systems (FACTS). The book covers comprehensively a range of power-system control problems: from steady-state voltage and power flow control, to voltage and reactive power control, to voltage stability control, to small signal stability control using FACTS controllers. In the six years since the first edition of the book has been published research on the FACTS has continued to flourish while renewable energy has developed into a mature and

  5. Network video transmission system based on SOPC

    Science.gov (United States)

    Zhang, Zhengbing; Deng, Huiping; Xia, Zhenhua

    2008-03-01

    Video systems have been widely used in many fields such as conferences, public security, military affairs and medical treatment. With the rapid development of FPGA, SOPC has been paid great attentions in the area of image and video processing in recent years. A network video transmission system based on SOPC is proposed in this paper for the purpose of video acquisition, video encoding and network transmission. The hardware platform utilized to design the system is an SOPC board of model Altera's DE2, which includes an FPGA chip of model EP2C35F672C6, an Ethernet controller and a video I/O interface. An IP core, known as Nios II embedded processor, is used as the CPU of the system. In addition, a hardware module for format conversion of video data, and another module to realize Motion-JPEG have been designed with Verilog HDL. These two modules are attached to the Nios II processor as peripheral equipments through the Avalon bus. Simulation results show that these two modules work as expected. Uclinux including TCP/IP protocol as well as the driver of Ethernet controller is chosen as the embedded operating system and an application program scheme is proposed.

  6. VSC-based HVDC with modular multilevel technology in praxis; VSC HGUemit Modularer Multilevel Technologie in der Praxis

    Energy Technology Data Exchange (ETDEWEB)

    Armonies, Uwe; Dommaschk, Mike; Retzmann, Dietmar; Wuerflinger, Klaus [Siemens AG, Erlangen (Germany). Energy Sector E T PS

    2011-07-01

    HVDC transmission is now being used to integrate offshore Windparks to Grid and feed power into the centre of large Metropolitan areas. For these applications the Voltage-Sourced Converter (VSV) using Modular Multilevel Technology is replacing the Classic Line-Commutated Converters and even VSCs using 2 or 3-level topologies. Modular Multilevel Converters comprise the series connection of many single modules, each with high energy storage, giving an almost linear control capability. The control of each module and its semi-conductors must produce balanced module loading. The analysis of real pulse patterns and measured data shows that the loading can be calculated by using idealized currents and voltages, which take into account the actual imbalance. In addition to the MMC control the balance of the arm energy plays a decisive role. Besides balancing the individual capacitor voltages by MMC control it is critical to control the energy of the individual arms. The basic functionality of this control system is demonstrated with real step response measurements. (orig.)

  7. Inertial Response of an Offshore Wind Power Plant with HVDC-VSC

    Energy Technology Data Exchange (ETDEWEB)

    Preciado, V.; Gevorgian, Vahan; Muljadi, Eduard; Madrigal, M.

    2017-01-05

    This paper analyzes the inertial response of an offshore wind power plant (WPP) to provide ancillary services to the power system grid. The WPP is connected to a high-voltage direct-current voltage source converter HVDC-VSC to deliver the power to the onshore substation. The wind turbine generator (WTG) used is a doubly-fed induction generator (Type 3 WTG). In this paper we analyze a control method for the WTGs in an offshore WPP to support the grid and contribute ancillary services to the power system network. Detailed time domain simulations will be conducted to show the transient behavior of the inertial response of an offshore WPP.

  8. Insulation systems for superconducting transmission cables

    DEFF Research Database (Denmark)

    Tønnesen, Ole

    1996-01-01

    This paper describes shortly the status of superconducting transmission lines and assesses what impact the recently discovered BSCCO superconductors may have on the design of the cables.Two basically different insulation systems are discussed:1) The room temperature dielectric design, where...... the electrical insulation is placed outside both the superconducting tube and the cryostat. The superconducting tube is cooled by liquid nitrogen which is pumped through the hollow part of the tube.2) The cryogenic dielectric design, where the electrical insulation is placed inside the cryostat and thus is kept...

  9. Droop Control Design of Multi-VSC Systems for Offshore Networks to Integrate Wind Energy

    Directory of Open Access Journals (Sweden)

    Muhammad Raza

    2016-10-01

    Full Text Available This research envisages the droop control design of multi voltage source converter systems for offshore networks to integrate wind power plant with the grids. An offshore AC network is formulated by connecting several nearby wind power plants together with AC cables. The net energy in the network is transferred to onshore using voltage source high voltage direct current (VSC-HVDC transmissionsystems. In the proposed configuration, an offshore network is energized by more than one VSC-HVDC system, hereby providing redundancy to continue operation in case of failure in one of the HVDC transmission lines. The power distribution between VSC-HVDC systems is done using a droop control scheme. Frequency droop is implemented to share active power, and voltage droop is implemented to share reactive power. Furthermore, a method of calculating droop gains according to the contribution factor of each converter is presented. The system has been analyzed to evaluate the voltage profile of the network affected by the droop control. Nonlinear dynamic simulation has been performed for the verification of the control principle.

  10. Outdoor polymeric insulators long-term exposed to HVDC

    Energy Technology Data Exchange (ETDEWEB)

    Soerqvist, T.; Vlastos, A.E. [Chalmers Univ. of Technology, Gothenburg (Sweden)

    1997-04-01

    Field experience from outdoor polymeric insulators exposed to HVDC under natural contamination conditions is presented. This paper summarizes the peak leakage current statistics, the hydrophobicity and the surface material conditions studied by electron spectroscopy for chemical analysis (ESCA) and attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy. The results show a strong interrelation between the surface conditions and the performance with respect to leakage currents. Moreover, the results show that the surface conditions and the performance of the insulators exposed to HVDC are rather similar to those of the insulators exposed to HVAC.

  11. On the use of programmable logical controllers (PLC) in the emergency control schemes for the 750 kV system

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Roberto Campos de; Oliveira, Mario Cesar Santos de [FURNAS, Rio de Janeiro, RJ (Brazil)

    1994-12-31

    The energy produced at the Itaipu Power Plant for the Brazilian Interconnected System is transmitted through two different transmission system: -HVDC system, with two bipoles of +- 600 kV, 6300 MW which connect the substation of Foz do Iguacu in the State of Parana, to substation of Ibiuna in the State of Sao Paulo, transmitting the energy generated in 50 Hz units. This system was entirely commissioned on september of 1987. (author) 3 refs., 5 figs.

  12. Approches pour la reduction de l'impact de defaut dans le transport d'energie du parc eolien offshore via VSC-HVDC =

    Science.gov (United States)

    Benadja, Mounir

    tenant compte des entrees de chacune des stations. L'integration des observateurs non-lineaires (EKF) dans le controle des convertisseurs permet de resoudre le probleme des incertitudes de mesure, des incertitudes dans la modelisation, en cas du dysfonctionnement ou de panne des capteurs de mesure ainsi que le probleme de l'impact des defauts (AC et DC) sur la qualite d'energie dans les systemes de transmission. Ces estimations contribuent a rendre le cout global du systeme moins cher et sa taille moins encombrante ainsi que la reduction de l'impact des defauts (AC et DC) sur le systeme. La troisieme contribution concerne la reduction de la taille, du cout et de l'impact des defauts electriques (AC et DC) dans le systeme construit pour transporter l'energie d'un parc eolien offshore (OWF) vers le reseau principal AC onshore via deux stations VSC-HVDC. La solution developpee utilise des observateurs non-lineaires bases sur le filtre de Kalman etendu (EKF). Ce filtre permet d'estimer la vitesse de rotation et la position du rotor de chacune des generatrices du parc eolien et de la tension du bus DC de l'onduleur DC-AC offshore. La contribution porte surtout sur le developpement des deux commandes des deux stations. La premiere, la commande non-lineaire modifiee pour controler le premier convertisseur de la station VSC-HVDC offshore assurant le transfert de la puissance generee par le parc eolien vers la station VSC-HVDC onshore. La deuxieme commande non-lineaire modifiee avec integration de la regulation de la tension du bus DC et de la commande a modele de reference adaptative (MRAC) pour la compensation des surintensites et surtensions durant les defauts AC et DC. On peut constater que lors d'un defaut AC au PCC (Point of Common Coupling) du cote reseau onshore, la profondeur de l'impact du defaut AC sur l'amplitude des courants du reseau principal AC onshore qui etait reduit a 60% par les travaux de recherche (Erlich, Feltes et Shewarega, 2014), comparativement a la

  13. Detailed Equivalent VSC-HVDC Modelling for Time Domain Harmonic Stability Studies in Wind Power Plants

    DEFF Research Database (Denmark)

    Glasdam, Jakob Bærholm; Bak, Claus Leth; Kocewiak, Lukasz Hubert

    2017-01-01

    system with 201 voltage levels, without loss of accuracy compared to conventional modelling of the converter. Harmonic stability is a core concern for both existing and future offshore wind power plants (OWPPs). A harmonic stability study will be undertaken with focus on the number of wind turbine...... generators in service, as this is known to influence the harmonic stability in OWPPs. The paper demonstrates the necessity of the inclusion of a detailed equivalent model of the HVDC converter for harmonic stability studies in the time domain. By implementation of active filtering in the converters...

  14. Flexible AC transmission systems: the state of the art

    Energy Technology Data Exchange (ETDEWEB)

    Edris, Abdel-Aty [Electric Power Research Inst., Palo Alto, CA (United States). Electric Systems Division

    1994-12-31

    Flexible AC transmission systems (FACTS) is a concept promoting the use of power electronic controllers to enhance the controllability and usable capacity of AC transmission. This paper presents the state of the art of FACTS and the status of the current projects for the application of the FACTS controllers in transmission systems. (author) 8 refs., 8 figs.

  15. Development of a HVDC prototype breaker. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Damsky, B L; Barkan, P; Imam, I; Permerlani, W; Anderson, J M; Carroll, J J; Hudson, J E; Pohl, R V; Solberg, W D; Sharbaugh, A H

    1980-06-01

    The significant design features of a high-voltage dc (HVDC) circuit breaker based on the commutation concept were developed. Tests of components indicate the breaker is capable of interrupting a fault current of 10 kA on a 400 kV system and absorbing up to 10 MJ of system energy without generating more than 1.6 per unit (P.U.) voltage of the system. Interactions of the breaker with a three-terminal network were studied, using a system simulator. An ultrafast hydraulic actuator system was developed for this program which enables the breaker to initiate the current limiting process within 5 ms after receipt of a trip signal. A new hydraulic valve, operated by a repulsion coil, minimizes the delay before motion begins. Interruption will occur in series-connected vacuum interrupters. A 400 kV circuit breaker is estimated to require eight breaks in series. Only a single break was tested as part of this program because of the scale and cost required for multibreak tests. System energy will be absorbed by zinc-oxide-based surge suppressors included as an integral part of the breaker. The overall design is envisioned as a dead tank type using pressurized SF/sub 6/ gas as a dielectric medium. The actuator and all control functions are located at ground potential, with easy access for inspection or adjustment. Operational specifications have been carried over from NEMA standards for ac power circuit breakers where applicable. The cost of one pole of this circuit breaker, when in regular production, has been estimated as two times the cost of a three-phase 500 kV ac circuit breaker.

  16. Frequency Support from OWPPs connected to HVDC via Diode Rectifiers

    DEFF Research Database (Denmark)

    Saborío-Romano, Oscar; Bidadfar, Ali; Göksu, Ömer

    This paper presents a study assessing the actual capability of an offshore wind power plant (offshore WPP, OWPP) to provide frequency support (FS) to an onshore network, when connected through a high-voltage direct-current (HVDC) link having a diode rectifier (DR) offshore terminal and a voltage...

  17. WSN-Based Space Charge Density Measurement System

    OpenAIRE

    Deng, Dawei; Yuan, Haiwen; Lv, Jianxun; Ju, Yong

    2017-01-01

    It is generally acknowledged that high voltage direct current (HVDC) transmission line endures the drawback of large area, because of which the utilization of cable for space charge density monitoring system is of inconvenience. Compared with the traditional communication network, wireless sensor network (WSN) shows advantages in small volume, high flexibility and strong self-organization, thereby presenting great potential in solving the problem. Additionally, WSN is more suitable for the co...

  18. Design of a modular, high step-up ratio DC–DC converter for HVDC applications integrating offshore wind power

    OpenAIRE

    Hu, Yihua; Zeng, Rong; Cao, Wenping; Zhang, Jiangfeng; Finney, Stephen J.

    2016-01-01

    High-power and high-voltage gain dc-dc converters are key to high-voltage direct current (HVDC) power transmission for offshore wind power. This paper presents an isolated ultra-high step-up dc-dc converter in matrix transformer configuration. A flyback-forward converter is adopted as the power cell and the secondary side matrix connection is introduced to increase the power level and to improve fault tolerance. Because of the modular structure of the converter, the stress on the switching de...

  19. IMPROVEMENT OF POWER SYSTEM QUALITY USING VSC ...

    African Journals Online (AJOL)

    The HVDC technology can be represented by the combination of a Direct Current (DC) circuit with two power electronics converters, each one at a link terminal, for AC/DC and DC/AC conversion The principal characteristic of VSC-HVDC transmission is its ability to independently control the reactive and real power flow at ...

  20. Application of optical transmission in control power system

    Science.gov (United States)

    Kuźma, Adam; Zajkowski, Maciej

    2011-06-01

    The advantage of fiber optic data transmission systems is their insensitivity to electromagnetic radiation, in which the optical fiber. Some exemplary applications of fiber optic transmission in power electronics and electric drives which due to their specific job bring significant electromagnetic interference. Electrical signal wires are in an area of very strong electromagnetic field so that the transmission distortion may occur. The paper presents existing and possible applications of optical links using optical fibers, in the control of power systems.

  1. Transmission techniques for emergent multicast and broadcast systems

    CERN Document Server

    da Silva, Mario Marques; Dinis, Rui; Souto, Nuno; Silva, Joao Carlos

    2010-01-01

    Describing efficient transmission schemes for broadband wireless systems, Transmission Techniques for Emergent Multicast and Broadcast Systems examines advances in transmission techniques and receiver designs capable of supporting the emergent wireless needs for multimedia broadcast and multicast service (MBMS) requirements. It summarizes the research and development taking place in wireless communications for multimedia MBMS and addresses the means to improved spectral efficiency to allow for increased user bit rate, as well as increased capacity of the digital cellular radio network.The text

  2. Adapting AC Lines to DC Grids for Large-Scale Renewable Power Transmission

    Directory of Open Access Journals (Sweden)

    D. Marene Larruskain

    2014-10-01

    Full Text Available All over the world, governments of different countries are nowadays promoting the use of clean energies in order to achieve sustainable energy systems. In this scenario, since the installed capacity is continuously increasing, renewable sources can play an important role. Notwithstanding that, some important problems may appear when connecting these sources to the grid, being the overload of distribution lines one of the most relevant. In fact, renewable generation is usually connected to the nearest AC grid, although this HV system may not have been designed considering distributed generation. In the particular case of large wind farms, the electrical grid has to transmit all the power generated by wind energy and, as a consequence, the AC system may get overloaded. It is therefore necessary to determine the impact of wind power transmission so that appropriate measures can be taken. Not only are these measures influenced by the amount of power transmitted, but also by the quality of the transmitted power, due to the output voltage fluctuation caused by the highly variable nature of wind. When designing a power grid, although AC systems are usually the most economical solution because of its highly proven technology, HVDC may arise in some cases (e.g. offshore wind farms as an interesting alternative, offering some added values such as lower losses and better controllability. This way, HVDC technology can solve most of the aforementioned problems and has a good potential for future use. Additionally, the fast development of power electronics based on new and powerful semiconductor devices allow the spread of innovative technologies, such as VSC-HVDC, which can be applied to create DC grids. This paper focuses on the main aspects involved in adapting the existing overhead AC lines to DC grids, with the objective of improving the transmission of distributed renewable energy to the centers of consumption.

  3. Radio frequency communication system utilizing radiating transmission lines

    Science.gov (United States)

    Struven, Warren C.

    1984-01-01

    A radio communication system for use in tunnels, mines, buildings or other shielded locations in which a pair of radiating transmission lines (30), (31) extend through such location in spaced coextensive relation to each other. Each transmission line (30), (31) has at least one unidirectional amplifier (32), (33) interposed therein with the sense of the unidirectional amplifier (32) of one transmission line (30) being opposite to the sense of the unidirectional amplifier (33) of the other transmission line (31). Each of the amplifiers (32), (33) has a gain which is less than the coupling loss between the transmission lines (30), (31). Two or more mobile transceivers (35) in the location served by the system are coupled to the transmission lines (30), (31) by electromagnetic wave propagation in space in order to communicate directly with each other at a given radio frequency within the frequency range of the system.

  4. 47 CFR 73.644 - Subscription TV transmission systems.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Subscription TV transmission systems. 73.644... RADIO BROADCAST SERVICES Television Broadcast Stations § 73.644 Subscription TV transmission systems. (a... increasing the RMS output power from either the video or audio transmitters over that required to transmit...

  5. 47 CFR 73.44 - AM transmission system emission limitations.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false AM transmission system emission limitations. 73... SERVICES RADIO BROADCAST SERVICES AM Broadcast Stations § 73.44 AM transmission system emission limitations... and suitable swept-frequency RF spectrum analyzer using a peak hold duration of 10 minutes, no video...

  6. 47 CFR 73.49 - AM transmission system fencing requirements.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false AM transmission system fencing requirements. 73.49 Section 73.49 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES RADIO BROADCAST SERVICES AM Broadcast Stations § 73.49 AM transmission system fencing requirements...

  7. Transmission of systemic AA amyloidosis in animals.

    Science.gov (United States)

    Murakami, T; Ishiguro, N; Higuchi, K

    2014-03-01

    Amyloidoses are a group of protein-misfolding disorders that are characterized by the deposition of amyloid fibrils in organs and/or tissues. In reactive amyloid A (AA) amyloidosis, serum AA (SAA) protein forms deposits in mice, domestic and wild animals, and humans that experience chronic inflammation. AA amyloid fibrils are abnormal β-sheet-rich forms of the serum precursor SAA, with conformational changes that promote fibril formation. Extracellular deposition of amyloid fibrils causes disease in affected animals. Recent findings suggest that AA amyloidosis could be transmissible. Similar to the pathogenesis of transmissible prion diseases, amyloid fibrils induce a seeding-nucleation process that may lead to development of AA amyloidosis. We review studies of possible transmission in bovine, avian, mouse, and cheetah AA amyloidosis.

  8. Optimization of transmission system design based on genetic algorithm

    Directory of Open Access Journals (Sweden)

    Xianbing Chen

    2016-05-01

    Full Text Available Transmission system is a crucial precision mechanism for twin-screw chemi-mechanical pulping equipment. The structure of the system designed by traditional method is not optimal because the structure designed by the traditional methods is easy to fall into the local optimum. To achieve the global optimum, this article applies the genetic algorithm which has grown in recent years in the field of structure optimization. The article uses the volume of transmission system as the objective function to optimize the structure designed by traditional method. Compared to the simulation results, the original structure is not optimal, and the optimized structure is tighter and more reasonable. Based on the optimized results, the transmission shafts in the transmission system are designed and checked, and the parameters of the twin screw are selected and calculated. The article provided an effective method to design the structure of transmission system.

  9. Cluster Control of Offshore Wind Power Plants Connected to a Common HVDC Station

    DEFF Research Database (Denmark)

    Göksu, Ömer; Sakamuri, Jayachandra N.; Rapp, C. Andrea

    2016-01-01

    In this paper a coordinated control for cluster of offshore WPPs connected to the same HVDC connection is being implemented and analyzed. The study is targeting two cases as; coordination of reactive power flow between HVDC converter and the WPP cluster while providing offshore AC grid voltage co...

  10. Security of the data transmission in the industrial control system

    Directory of Open Access Journals (Sweden)

    Marcin Bednarek

    2015-12-01

    Full Text Available The theme of this paper is to present the data transmission security system between the stations of the industrial control system. The possible options for secure communications between process stations, as well as between process and operator station are described. Transmission security mechanism is based on algorithms for symmetric and asymmetric encryption. The authentication process uses a software token algorithm and a one-way hash function. The algorithm for establishing a secured connection between the stations, including the authentication process and encryption of data transmission is given. The process of securing the transmission consists of 4 sub-processes: (I authentication; (II asymmetric, public keys transmission; (III symmetric key transmission; (IV data transmission. The presented process of securing the transmission was realized in the industrial controller and emulator. For this purpose, programming languages in accordance with EN 61131 were used. The functions were implemented as user function blocks. This allows us to include a mixed code in the structure of the block (both: ST and FBD. Available function categories: support of the asymmetric encryption; asymmetric encryption utility functions; support of the symmetric encryption; symmetric encryption utility functions; support of the hash value calculations; utility functions of conversion.[b]Keywords[/b]: transmission security, encryption, authentication, industrial control system

  11. Research on Travel Control System of Hydrostatic Transmission Chassis

    Directory of Open Access Journals (Sweden)

    Zhao Liang

    2017-01-01

    Full Text Available Aiming at the control problem of driving system of hydrostatic transmission chassis, the composition of the control system of hydrostatic transmission chassis is introduced and the control method of dual engine is solved. According to the number of driving axles in driving process, The external characteristic curve of the engine controls the variable hydraulic pump by one parameter, controls the rotational speed of the variable hydraulic motor according to the change of the vehicle speed, and introduces the control flow of the brake system. It provides a reference for the design of driving control system of multi-axis hydrostatic transmission chassis.

  12. Distance Protection of Cross-Bonded Transmission Cable-Systems

    DEFF Research Database (Denmark)

    Bak, Claus Leth; F. Jensen, Christian

    2014-01-01

    In this paper the problems of protecting a cross-bonded cable system using distance protection are analysed. The combination of the desire to expand the high voltage transmission grid and the public's opinion towards new installations of overhead lines (OHL), more and more transmission cable syst...

  13. Determination of Transmission Limits on Electric Power Systems

    Directory of Open Access Journals (Sweden)

    Castellanos-Bustamante Rafael

    2014-04-01

    Full Text Available This article provides the application of several methodologies to obtain power transmission limits through interties of the electric power systems to obtain a secure operation of the energy power system. Several aspects to obtain the maximum power flows of electrical energy thought of transmission lines on electrical grids are shown. Thermal limit of electrical conductors, loadability limit of transmission lines and small signal stability limits are obtained for several interties between geographical regions. It also, shows the application of a load shedding scheme to stabilize an interarea oscillation mode. The model of the Mexican Interconnected power System is used to illustrate these methodologies.

  14. INFORMATION-MEASURING TEST SYSTEM OF DIESEL LOCOMOTIVE HYDRAULIC TRANSMISSIONS

    Directory of Open Access Journals (Sweden)

    I. V. Zhukovytskyy

    2015-08-01

    Full Text Available Purpose. The article describes the process of developing the information-measuring test system of diesel locomotives hydraulic transmission, which gives the possibility to obtain baseline data to conduct further studies for the determination of the technical condition of diesel locomotives hydraulic transmission. The improvement of factory technology of post-repair tests of hydraulic transmissions by automating the existing hydraulic transmission test stands according to the specifications of the diesel locomotive repair enterprises was analyzed. It is achieved based on a detailed review of existing foreign information-measuring test systems for hydraulic transmission of diesel locomotives, BelAZ earthmover, aircraft tug, slag car, truck, BelAZ wheel dozer, some brands of tractors, etc. The problem for creation the information-measuring test systems for diesel locomotive hydraulic transmission is being solved, starting in the first place from the possibility of automation of the existing test stand of diesel locomotives hydraulic transmission at Dnipropetrovsk Diesel Locomotive Repair Plant "Promteplovoz". Methodology. In the work the researchers proposed the method to create a microprocessor automated system of diesel locomotives hydraulic transmission stand testing in the locomotive plant conditions. It acts by justifying the selection of the necessary sensors, as well as the application of the necessary hardware and software for information-measuring systems. Findings. Based on the conducted analysis there was grounded the necessity of improvement the plant hydraulic transmission stand testing by creating a microprocessor testing system, supported by the experience of developing such systems abroad. Further research should be aimed to improve the accuracy and frequency of data collection by adopting the more modern and reliable sensors in tandem with the use of filtering software for electromagnetic and other interference. Originality. The

  15. Enhanced Voltage Control of VSC-HVDC Connected Offshore Wind Farms Based on Model Predictive Control

    DEFF Research Database (Denmark)

    Guo, Yifei; Gao, Houlei; Wu, Qiuwei

    2017-01-01

    This paper proposes an enhanced voltage control strategy (EVCS) based on model predictive control (MPC) for voltage source converter based high voltage direct current (VSCHVDC) connected offshore wind farms (OWFs). In the proposed MPC based EVCS, all wind turbine generators (WTGs) as well...... as the wind farm side VSC are optimally coordinated to keep voltages within the feasible range and reduce system power losses. Considering the high ratio of the OWF collector system, the effects of active power outputs of WTGs on voltage control are also taken into consideration. The predictive model of VSC...... with a typical cascaded control structure is derived in details. The sensitivity coefficients are calculated by an analytical method to improve the computational efficiency. A VSC-HVDC connected OWF with 64 WTGs was used to validate the proposed voltage control strategy....

  16. EHV/HV Underground Cable Systems for Power Transmission

    DEFF Research Database (Denmark)

    Bak, Claus Leth

    are to be found. One very good example of this is offshore wind power plants. The current transmission system is laid out in a traditional manner, which is based on the idea of not transporting power over longer distances as the power plants have been located near centres of consumption. It has merely played...... of the transmission system must be re‐thought in order to accommodate the transmission needs for the future. New lines have to be constructed. Transmission lines are usually laid out as overhead lines, which are large structures, i.e. a 400 kV power pylon is 50 meters high. According to public opinion, such power...... lines are undesirable. Therefore, we must come up with an alternative, acceptable to the public. Underground cables fulfil the above mentioned need to be more publically acceptable, but, for long transmission lines, they are in many ways unproven. Guidelines for their design are needed. This thesis...

  17. The Applicability of Traditional Protection Methods to Lines Emanating from VSC-HVDC Interconnectors and a Novel Protection Principle

    Directory of Open Access Journals (Sweden)

    Shimin Xue

    2016-05-01

    Full Text Available Voltage source converter (VSC-based high voltage direct current (VSC-HVDC interconnectors can realize accurate and fast control of power transmission among AC networks, and provide emergency power support for AC networks. VSC-HVDC interconnectors bring exclusive fault characteristics to AC networks, thus influencing the performance of traditional protections. Since fault characteristics are related to the control schemes of interconnectors, a fault ride-through (FRT strategy which is applicable to the interconnector operating characteristic of working in four quadrants and capable of eliminating negative-sequence currents under unbalanced fault conditions is proposed first. Then, the additional terms of measured impedances of distance relays caused by fault resistances are derived using a symmetrical component method. Theoretical analysis shows the output currents of interconnectors are controllable after faults, which may cause malfunctions in distance protections installed on lines emanating from interconnectors under the effect of fault resistances. Pilot protection is also inapplicable to lines emanating from interconnectors. Furthermore, a novel pilot protection principle based on the ratio between phase currents and the ratio between negative-sequence currents flowing through both sides is proposed for lines emanating from the interconnectors whose control scheme aims at eliminating negative-sequence currents. The validity of theoretical analysis and the protection principle is verified by PSCAD/EMTDC simulations.

  18. Distance Protection of Cross-Bonded Transmission Cable-Systems

    OpenAIRE

    Bak, Claus Leth; F. Jensen, Christian

    2014-01-01

    In this paper the problems of protecting a cross-bonded cable system using distance protection are analysed. The combination of the desire to expand the high voltage transmission grid and the public's opinion towards new installations of overhead lines (OHL), more and more transmission cable systems are being laid around the world. Differential protection is often used for the main protection of cables. As a backup protection, distance protection is very often the preferred choice. Therefore,...

  19. Alternative electrical transmission systems and their environmental impact

    Energy Technology Data Exchange (ETDEWEB)

    Schiefelbein, G.F.

    1977-08-01

    A general description is provided of electrical transmission systems as an aid in determining their environmental impacts. Alternating current, direct current, overhead systems, underground systems, and water crossings are treated. The cost, performance, reliability, safety, and environmental impact of these systems are compared.

  20. Coordinated Voltage Control in Offshore HVDC Connected Cluster of Wind Power Plants

    DEFF Research Database (Denmark)

    Sakamuri, Jayachandra N.; Rather, Zakir Hussain; Rimez, Johan

    2016-01-01

    This paper presents a coordinated voltage control scheme (CVCS) for a cluster of offshore wind power plants (OWPPs) connected to a VSC HVDC system. The primary control point of the proposed voltage control scheme is the introduced Pilot bus, which is having the highest short circuit capacity...... in the offshore AC grid. The developed CVCS comprehends an optimization algorithm, aiming for minimum active power losses in the offshore grid, to generate voltage reference to the Pilot bus. During steady state operation, the Pilot bus voltage is controlled by dispatching reactive power references to each wind...... turbine (WT) in the WPP cluster based on their available reactive power margin and network sensitivity based participation factors, which are derived from the dV/dQ sensitivity of a WT bus w.r.t the Pilot bus. This method leads to minimization of the risk of undesired effects, particularly overvoltage...

  1. Transmission Reinforcements in the Central American Regional Power System

    Energy Technology Data Exchange (ETDEWEB)

    Elizondo, Marcelo A.; Vallem, Mallikarjuna R.; Samaan, Nader A.; Makarov, Yuri V.; Vyakaranam, Bharat; Nguyen, Tony B.; Munoz, Christian; Herrera, Ricardo; Midence, Diego; Shpitsberg, Anna

    2016-07-25

    The Central American regional interconnected power system (SER) connects the countries members of the Central American regional electricity market (MER): Guatemala, El Salvador, Honduras, Nicaragua, Costa Rica, and Panama. The SER was a result of a long term regional effort, and was initially conceived to transfer 300 MW between countries. However, the current transfer limits between countries range from 70 MW to 300 MW. Regional entities, like CRIE (Regional Commission of Electrical Interconnection), EOR (Central American Regional System Operator), and CDMER (Board of Directors of the Central American Market) are working on coordinating the national transmission expansion plans with regional transmission planning efforts. This paper presents experience in Central America region to recommend transmission reinforcements to achieve 300 MW transfer capacity between any pair of member countries of the Central American regional electricity market (MER). This paper also provides a methodology for technical analysis and for coordination among the regional and national entities. This methodology is unique for transmission systems of these characteristics.

  2. Layered Video Transmission on Adaptive OFDM Wireless Systems

    Directory of Open Access Journals (Sweden)

    D. Dardari

    2004-09-01

    Full Text Available Future wireless video transmission systems will consider orthogonal frequency division multiplexing (OFDM as the basic modulation technique due to its robustness and low complexity implementation in the presence of frequency-selective channels. Recently, adaptive bit loading techniques have been applied to OFDM showing good performance gains in cable transmission systems. In this paper a multilayer bit loading technique, based on the so called “ordered subcarrier selection algorithm,” is proposed and applied to a Hiperlan2-like wireless system at 5 GHz for efficient layered multimedia transmission. Different schemes realizing unequal error protection both at coding and modulation levels are compared. The strong impact of this technique in terms of video quality is evaluated for MPEG-4 video transmission.

  3. System life and reliability modeling for helicopter transmissions

    Science.gov (United States)

    Savage, M.; Brikmanis, C. K.

    1986-01-01

    A computer program which simulates life and reliability of helicopter transmissions is presented. The helicopter transmissions may be composed of spiral bevel gear units and planetary gear units - alone, in series or in parallel. The spiral bevel gear units may have either single or dual input pinions, which are identical. The planetary gear units may be stepped or unstepped and the number of planet gears carried by the planet arm may be varied. The reliability analysis used in the program is based on the Weibull distribution lives of the transmission components. The computer calculates the system lives and dynamic capacities of the transmission components and the transmission. The system life is defined as the life of the component or transmission at an output torque at which the probability of survival is 90 percent. The dynamic capacity of a component or transmission is defined as the output torque which can be applied for one million output shaft cycles for a probability of survival of 90 percent. A complete summary of the life and dynamic capacity results is produced by the program.

  4. Reliability Analysis of Random Vibration Transmission Path Systems

    OpenAIRE

    Wei Zhao; Yi-Min Zhang

    2017-01-01

    The vibration transmission path systems are generally composed of the vibration source, the vibration transfer path, and the vibration receiving structure. The transfer path is the medium of the vibration transmission. Moreover, the randomness of transfer path influences the transfer reliability greatly. In this paper, based on the matrix calculus, the generalized second moment technique, and the stochastic finite element theory, the effective approach for the transfer reliability of vibratio...

  5. Technology Transmission Across National Innovation Systems

    DEFF Research Database (Denmark)

    Haakonsson, Stine Jessen; Slepniov, Dmitrij

    innovation systems (NIS) and firm level capabilities. The paper employs a qualitative methodology, drawing on explorative case studies of component suppliers and their links to lead firms in the wind turbine industry. The findings of the paper highlight the new pattern of upgrading by upstream linkages, i.......e. linking up with global suppliers in the wind turbine global value chain, and the new role of component suppliers as technology transmitters across national innovation systems into emerging markets. Conceptually, the paper contributes to understanding how technological catching up in value chains links...... to the intersection between national innovation systems, a process driven by global value chain dynamics....

  6. Theoretical Analysis of Tuned HVAC Line for Low Loss Long Distance Bulk Power Transmission

    OpenAIRE

    Ukil, Abhisek

    2015-01-01

    One of the main objectives of the smart grid initiative is to enable bulk power transmission over long distance, with reduced transmission losses. Besides the traditional high-voltage alternating current (HVAC) transmission, with the advancement in power electronics, high-voltage direct current (HVDC) transmission is increasingly becoming important. One of the main factors impacting the transmission line parameters and the losses is the length of the transmission line (overhead). In this pape...

  7. Advanced modulation formats for transmission systems

    DEFF Research Database (Denmark)

    Tokle, Torger; Serbay, M.; Jensen, Jesper Bevensee

    2008-01-01

    DQPSK has shown that multilevel modulation formats can enable new possibilities in optical communication systems. The paper presents several options to go to even more advanced formats using direct detection....

  8. Design of UAV high resolution image transmission system

    Science.gov (United States)

    Gao, Qiang; Ji, Ming; Pang, Lan; Jiang, Wen-tao; Fan, Pengcheng; Zhang, Xingcheng

    2017-02-01

    In order to solve the problem of the bandwidth limitation of the image transmission system on UAV, a scheme with image compression technology for mini UAV is proposed, based on the requirements of High-definition image transmission system of UAV. The video codec standard H.264 coding module and key technology was analyzed and studied for UAV area video communication. Based on the research of high-resolution image encoding and decoding technique and wireless transmit method, The high-resolution image transmission system was designed on architecture of Android and video codec chip; the constructed system was confirmed by experimentation in laboratory, the bit-rate could be controlled easily, QoS is stable, the low latency could meets most applied requirement not only for military use but also for industrial applications.

  9. Data transmission system with encryption by chaotic sequences

    Directory of Open Access Journals (Sweden)

    Politans’kyy R. L.

    2014-06-01

    Full Text Available Protection of transferable information in the telecommunication systems is possible by its imposition of coding sequence on a plaintext. Encryption of pseudorandom sequences can be performed by using generation algorithms which are implemented on the basis of the phenomenon of dynamical chaos, which is sensitive to changes in the initial conditions. One of the major problems encountered in the construction of secure communication systems is to provide synchronization between the receiving and transmitting parties of communication systems. Improvement of methods of hidden data transfer based on the systems with chaotic synchronization is the important task of research in the field of information and telecommunication systems based on chaos. This article shows an implementation of a data transmission system, encrypted by sequences, generated on the basis of one-dimensional discrete chaotic maps with ensuring synchronization of the transmitting and receiving sides of the system. In this system realization of synchronization is offered by a transmission through certain time domains of current value of xn generated by a logistic reflection. Xn transmission period depends on computer speed and distance between subscribers of the system. Its value is determined by transmitting a test message before the session. Infallible reception of test message indicates the optimal choice of a transmission period of the current value of xn. Selection period is done at the program level. For the construction of communication network modern software was used, in particular programming language Delphi 7.0. The work of the system is shown on the example of information transmission between the users of the system. The system operates in real time full duplex mode at any hardware implementation of Internet access. It is enough for the users of the system to specify IP address only.

  10. FPGA Implementation of Video Transmission System Based on LTE

    Directory of Open Access Journals (Sweden)

    Lu Yan

    2015-01-01

    Full Text Available In order to support high-definition video transmission, an implementation of video transmission system based on Long Term Evolution is designed. This system is developed on Xilinx Virtex-6 FPGA ML605 Evaluation Board. The paper elaborates the features of baseband link designed in Xilinx ISE and protocol stack designed in Xilinx SDK, and introduces the process of setting up hardware and software platform in Xilinx XPS. According to test, this system consumes less hardware resource and is able to transmit bidirectional video clearly and stably.

  11. Characterization of a 300-GHz Transmission System for Digital Communications

    Science.gov (United States)

    Hudlička, Martin; Salhi, Mohammed; Kleine-Ostmann, Thomas; Schrader, Thorsten

    2017-08-01

    The paper presents the characterization of a 300-GHz transmission system for modern digital communications. The quality of the modulated signal at the output of the system (error vector magnitude, EVM) is measured using a vector signal analyzer. A method using a digital real-time oscilloscope and consecutive mathematical processing in a computer is shown for analysis of signals with bandwidths exceeding that of state-of-the-art vector signal analyzers. The uncertainty of EVM measured using the real-time oscilloscope is open to analysis. Behaviour of the 300-GHz transmission system is studied with respect to various modulation schemes and different signal symbol rates.

  12. Implementation of image transmission server system using embedded Linux

    Science.gov (United States)

    Park, Jong-Hyun; Jung, Yeon Sung; Nam, Boo Hee

    2005-12-01

    In this paper, we performed the implementation of image transmission server system using embedded system that is for the specified object and easy to install and move. Since the embedded system has lower capability than the PC, we have to reduce the quantity of calculation of the baseline JPEG image compression and transmission. We used the Redhat Linux 9.0 OS at the host PC and the target board based on embedded Linux. The image sequences are obtained from the camera attached to the FPGA (Field Programmable Gate Array) board with ALTERA cooperation chip. For effectiveness and avoiding some constraints from the vendor's own, we made the device driver using kernel module.

  13. Wireless OAM transmission system based on elliptical microstrip patch antenna.

    Science.gov (United States)

    Chen, Jia Jia; Lu, Qian Nan; Dong, Fei Fei; Yang, Jing Jing; Huang, Ming

    2016-05-30

    The multiplexing transmission has always been a focus of attention for communication technology. In this paper, the radiation characteristics of circular microstrip patch antenna was firstly analyzed based on cavity model theory, and then spiral beams carrying orbital angular momentum (OAM) were generated, using elliptical microstrip patch antenna, with a single feed probe instead of a standard circular patch with two feedpoints. Moreover, by combining the proposed elliptic microstrip patch antenna with Universal Software Radio Peripheral (USRP), a wireless OAM transmission system was established and the real-time transmission of text, image and video in a real channel environment was realized. Since the wireless OAM transmission has the advantage of good safety and high spectrum utilization efficiency, this work has theoretical significance and potential application.

  14. Single transmission line interrogated multiple channel data acquisition system

    Science.gov (United States)

    Fasching, George E.; Keech, Jr., Thomas W.

    1980-01-01

    A single transmission line interrogated multiple channel data acquisition system is provided in which a plurality of remote station/sensor circuits each monitors a specific process variable and each transmits measurement values over a single transmission line to a master interrogating station when addressed by said master interrogating station. Typically, as many as 330 remote stations may be parallel connected to the transmission line which may exceed 7,000 feet. The interrogation rate is typically 330 stations/second. The master interrogating station samples each station according to a shared, charging transmit-receive cycle. All remote station address signals, all data signals from the remote stations/sensors and all power for all of the remote station/sensors are transmitted via a single continuous terminated coaxial cable. A means is provided for periodically and remotely calibrating all remote sensors for zero and span. A provision is available to remotely disconnect any selected sensor station from the main transmission line.

  15. 47 CFR 73.1350 - Transmission system operation.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Transmission system operation. 73.1350 Section... system must provide this capability continuously or must include an alternate method of acquiring control... required. In such cases, operation must be terminated within three minutes unless antenna input power is...

  16. Advanced fault ride-through control of DFIG based wind turbines including grid connection via VSC-HVDC

    Energy Technology Data Exchange (ETDEWEB)

    Feltes, Christian

    2012-07-01

    With the growing renewable energy share in the power generation mix it becomes inevitable that also these new generation technologies participate on the provision of grid services to guarantee stable operation of the grid, especially when one considers the decreasing number of conventional power plants in operation as a result of the expansion of wind based generation plants. These so-called ancillary services include frequency / active power control, voltage / reactive power control and fault ride-through (FRT) with fast voltage control and are stipulated in modern grid codes. In the context of this thesis advanced control algorithms have been developed for wind turbines based on doubly-fed induction generator (DFIG) to allow safe FRT during symmetrical and unsymmetrical faults. This covers the control for conventional AC grid connection as well as for the connection through voltage source converter (VSC) based high voltage direct current transmission (HVDC). Currently, the DFIG is the most used generator technology in modem wind turbines, since it combines a relatively simple slip-ring induction machine with a frequency converter rated to only approx. 30% of the total power. This makes the DFIG a cost-effective concept, which offers a variable speed range and a high degree of flexibility in control. However, due to the direct coupling of the generator stator circuit to the grid, grid faults are a special challenge for the frequency converter, its protection circuits and control algorithms. As base for the detailed evaluation of the impact of grid faults to the DFIG, this thesis contains the analytical derivation of the DFIG short circuit currents under consideration of frequency converter control. The DFIG concept presented in this thesis makes use of a DC chopper in the frequency converter, which allows safe FRT with grid voltage support through both converter sides. The developed control contains a new algorithm for a clear separation and control of positive

  17. HVDC grid test models for different application scenarios and load flow studies

    National Research Council Canada - National Science Library

    AN, Ting; HAN, Congda; WU, Yanan; TANG, Guangfu

    .... A HVDC grid test model can provide a common reference and study platform for researchers to compare the performance and characteristics of a DC grid with different DC control functions and protection strategies...

  18. Transmission of Muons in an Alternating Gradient Funneling System

    CERN Document Server

    Meot, Francois; Lemuet, Franck

    2003-01-01

    One important issue in a neutrino factory is the target system for pion production. The A.G. funneling system addressed here consists of four horns, with 1 MW target per horn, followed by a recombination A.G. channel and a FODO decay channel. The transmission of this scheme is analyzed in detail. It is compared with that of a simple solenoid for several sets of optics parameters. This study makes it possible to gain in transmission efficiency in comparison with earlier proposals.

  19. Steady-state and transient performance of HVDC link based 3-level ...

    African Journals Online (AJOL)

    Administrateur

    B. VSC_HVDC response to external AC faults at the inverter side. (load) & the dc line. 4.1. Case 1. A single phase to ground fault was first applied at t = 2.8s during 0.1s (5 cycles) at station 1 (Fig. 6) AC bus in order to investigate the behavior of VSC-HVDC during unbalanced faults. Figure 7 presents the simulations results.

  20. Automatic Voltage Control (AVC) of Danish Transmission System - Concept design

    DEFF Research Database (Denmark)

    Qin, Nan; Abildgaard, Hans; Lund, P.

    2014-01-01

    . Another consequence is the public way of generally thinking green which have led to a national decision of undergrounding not only all of the Danish distribution system but also the future transmission system. These issues initiate the infrastructure constructions of the transmission system i.e. a large......, objectives, constraints, algorithms for optimal power flow and some special functions in particular systems, which inspires the concept design of a Danish AVC system to address the future challenges of voltage control. In the concept, the Danish AVC design is based on a centralized control scheme. All...... the buses are monitored where the voltage magnitudes are maintained continually. The loss minimization including switching cost is the objectives of the AVC system. The reactive power reserves as constraints are taken into account to limit the regulation capabilities of generators. The Day ahead and short...

  1. Reliability Analysis of Random Vibration Transmission Path Systems

    Directory of Open Access Journals (Sweden)

    Wei Zhao

    2017-01-01

    Full Text Available The vibration transmission path systems are generally composed of the vibration source, the vibration transfer path, and the vibration receiving structure. The transfer path is the medium of the vibration transmission. Moreover, the randomness of transfer path influences the transfer reliability greatly. In this paper, based on the matrix calculus, the generalized second moment technique, and the stochastic finite element theory, the effective approach for the transfer reliability of vibration transfer path systems was provided. The transfer reliability of vibration transfer path system with uncertain path parameters including path mass and path stiffness was analyzed theoretically and computed numerically, and the correlated mathematical expressions were derived. Thus, it provides the theoretical foundation for the dynamic design of vibration systems in practical project, so that most random path parameters can be considered to solve the random problems for vibration transfer path systems, which can avoid the system resonance failure.

  2. A miniaturized digital telemetry system for physiological data transmission

    Science.gov (United States)

    Portnoy, W. M.; Stotts, L. J.

    1978-01-01

    A physiological date telemetry system, consisting basically of a portable unit and a ground base station was designed, built, and tested. The portable unit to be worn by the subject is composed of a single crystal controlled transmitter with AM transmission of digital data and narrowband FM transmission of voice; a crystal controlled FM receiver; thirteen input channels follwed by a PCM encoder (three of these channels are designed for ECG data); a calibration unit; and a transponder control system. The ground base station consists of a standard telemetry reciever, a decoder, and an FM transmitter for transmission of voice and transponder signals to the portable unit. The ground base station has complete control of power to all subsystems in the portable unit. The phase-locked loop circuit which is used to decode the data, remains in operation even when the signal from the portable unit is interrupted.

  3. 47 CFR 73.687 - Transmission system requirements.

    Science.gov (United States)

    2010-10-01

    ... RADIO BROADCAST SERVICES Television Broadcast Stations § 73.687 Transmission system requirements. (a... modulating frequency of 1.25 MHz or greater and in addition, for color, shall not be greater than −42 dB for a modulating frequency of 3.579545 MHz (the color subcarrier frequency). For both monochrome and...

  4. Stokes Space in Direct-Detection Data Transmission Systems

    DEFF Research Database (Denmark)

    Estaran Tolosa, Jose Manuel; Lu, Xiaofeng; Zibar, Darko

    2015-01-01

    Stokes-based processing permits complete and phase-insensitive characterization of the field’s SOP, readily unlocking polarization diversity in transmission systems where DD is desired. We present an overview on Stokes notions and most recent achievements in this context....

  5. Computer-aided Instructional System for Transmission Line Simulation.

    Science.gov (United States)

    Reinhard, Erwin A.; Roth, Charles H., Jr.

    A computer-aided instructional system has been developed which utilizes dynamic computer-controlled graphic displays and which requires student interaction with a computer simulation in an instructional mode. A numerical scheme has been developed for digital simulation of a uniform, distortionless transmission line with resistive terminations and…

  6. Limiting electric fields of HVDC overhead power lines.

    Science.gov (United States)

    Leitgeb, N

    2014-05-01

    As a consequence of the increased use of renewable energy and the now long distances between energy generation and consumption, in Europe, electric power transfer by high-voltage (HV) direct current (DC) overhead power lines gains increasing importance. Thousands of kilometers of them are going to be built within the next years. However, existing guidelines and regulations do not yet contain recommendations to limit static electric fields, which are one of the most important criteria for HVDC overhead power lines in terms of tower design, span width and ground clearance. Based on theoretical and experimental data, in this article, static electric fields associated with adverse health effects are analysed and various criteria are derived for limiting static electric field strengths.

  7. Impact of transmission parameters on Nyquist WDM system

    Science.gov (United States)

    Kowalczyk, Agnieszka; Perlicki, Krzysztof

    2015-09-01

    In this paper the analysis of the transmission quality in Nyquist WDM transport system is presented. Results are presented of a system simulation carried out for different modulation format, symbol rates, channel spacing and filter characteristics of the transmitter and receiver. This paper also contains the comparison between results obtained for the N-WDM (Nyquist Wavelength Division Multiplexing) and DWDM (Dense Wavelength Division Multiplexing) system. Two quality indicators are taken into consideration: interchannel crosstalk and symbol error rate for both different system configurations.

  8. A nano continuously variable transmission system from nanotubes.

    Science.gov (United States)

    Cai, Kun; Shi, Jiao; Xie, Yi Min; Qin, Qing-Hua

    2017-12-18

    A nano continuously variable transmission (nano-CVT) system is proposed by means of carbon nanotubes (CNT). The dynamic behavior of the CNT-based nanosystem is assessed using molecular dynamics simulations. In the system, a rotary CNT-motor and a CNT-bearing are contained. The tube axes of the nanomotor and the rotor in the bearing are laid in parallel, and their distance is known as the eccentricity of the rotor with a diameter of d. By changing the eccentricity (e) of the rotor from 0 to d, some interesting phenomena on rotation transmission are discovered, whose procedure can be used to design various nanodevices. For example, the phenomena might be the failure of rotation transmission, i.e., the rotor has no rotation, when e≥d at extremely low temperature, or when the two tubes' edges are orthogonal at their intersections at any conditions. It hints that the state of the nanosystem can be used as an on/off switch or breaker. For the system with e=d and at high temperature, the rotor rotates reversely to the motor. It means that the output signal (rotation) is reverse to the input signal. When changing the eccentricity from 0 to d continuously, the output signal decreases from positive value to the negative value, gradually. As a result, a nano-CVT system is obtained. © 2017 IOP Publishing Ltd.

  9. Data Acquisition and Transmission System for Building Energy Consumption Monitoring

    Directory of Open Access Journals (Sweden)

    Liang Zhao

    2013-01-01

    Full Text Available Building energy consumption monitoring and management system have been developed widely in China in order to gain the real-time data of energy consumption in buildings for analyzing it in the next state work. This paper describes a low-cost and small-sized collector based on the STM32 microcontroller, which can be placed in a building easily to implement the work of data acquisition, storage, and transmission. The collector gathers the electricity, water, heat, and energy consumption data through the RS485 field bus and stores the data into an SD card with mass storage, finally, using Internet to finish the communication and transmission to data server through TCP protocol. The collector has been used in application for two years, and the results show that the system is reliable and stable.

  10. Portable wireless power transmission system for video capsule endoscopy.

    Science.gov (United States)

    Zhiwei, Jia; Guozheng, Yan; Bingquan, Zhu

    2014-10-01

    Wireless power transmission is considered a practical way of overcoming the power shortage of wireless capsule endoscopy (VCE). However, most patients cannot tolerate the long hours of lying in a fixed transmitting coil during diagnosis. To develop a portable wireless power transmission system for VCE, a compact transmitting coil and a portable inverter circuit driven by rechargeable batteries are proposed. The couple coils, optimized considering the stability and safety conditions, are 28 turns of transmitting coil and six strands of receiving coil. The driven circuit is designed according to the portable principle. Experiments show that the integrated system could continuously supply power to a dual-head VCE for more than 8 h at a frame rate of 30 frames per second with resolution of 320 × 240. The portable VCE exhibits potential for clinical applications, but requires further improvement and tests.

  11. A Multiple-Antenna System for ISM-Band Transmission

    Directory of Open Access Journals (Sweden)

    Rinas J

    2004-01-01

    Full Text Available We present a multiple antenna system for industrial, scientific, and medical (ISM-band transmission (MASI. The hardware demonstrator was developed and realized at our institute. It enables multiple-input multiple-output (MIMO-communication applications and is capable of transmiting arbitrary signals using transmit and receive antennas in parallel. It operates in the 2.4 GHz ISM-band. The hardware concept is introduced and some design specifications are discussed. Using this transmission system, we present some measurement results to show the feasibility of MIMO concepts currently under discussion. The applications include transmit and receive diversity for single carrier and OFDM as well as blind source separation (BSS techniques.

  12. Reduction and power losses in transmission and distribution systems

    Energy Technology Data Exchange (ETDEWEB)

    Herrera, J.I.; Reed, J.H.; Reddoch, T.W.

    1988-08-30

    The very real power crisis in many developing countries calls for both innovativeness and efficiency in meeting the needs for electric power posed by social and economic development. One of the key elements in such a strategy is improving the efficiency of electricity transmission and distribution (in other words, reducing unnecessary losses in these parts of a power system). United Nations data, self-reported by individual countries, suggest that average losses in transmission and distribution systems across the region are about 13%. Other data, however, indicate that losses in many countries are on the order of 50% higher than the UN figures; for example, recent data suggest that losses in one country within the region are more than 30%. 22 refs., 8 figs., 3 tabs.

  13. A Case Study of Wind-PV-Thermal-Bundled AC/DC Power Transmission from a Weak AC Network

    Science.gov (United States)

    Xiao, H. W.; Du, W. J.; Wang, H. F.; Song, Y. T.; Wang, Q.; Ding, J.; Chen, D. Z.; Wei, W.

    2017-05-01

    Wind power generation and photovoltaic (PV) power generation bundled with the support by conventional thermal generation enables the generation controllable and more suitable for being sent over to remote load centre which are beneficial for the stability of weak sending end systems. Meanwhile, HVDC for long-distance power transmission is of many significant technique advantages. Hence the effects of wind-PV-thermal-bundled power transmission by AC/DC on power system have become an actively pursued research subject recently. Firstly, this paper introduces the technical merits and difficulties of wind-photovoltaic-thermal bundled power transmission by AC/DC systems in terms of meeting the requirement of large-scale renewable power transmission. Secondly, a system model which contains a weak wind-PV-thermal-bundled sending end system and a receiving end system in together with a parallel AC/DC interconnection transmission system is established. Finally, the significant impacts of several factors which includes the power transmission ratio between the DC and AC line, the distance between the sending end system and receiving end system, the penetration rate of wind power and the sending end system structure on system stability are studied.

  14. Downlink transmission in multi-carrier systems with reduced feedback

    DEFF Research Database (Denmark)

    Wang, Yuanye; Pedersen, Klaus; Sørensen, Troels Bundgaard

    2010-01-01

    in this paper we address the problem of reducing the feedback for the downlink transmission in multi-carrier systems. In these systems multiple Component Carriers (CCs) are aggregated together to form a wide spectrum. Consequently, a large feedback overhead is required to report the channel quality...... overhead in future generation wireless communication systems that operate over multiple CCs....... information over such a wide bandwidth. We first generalize two existing feedback reduction techniques, and then propose a new one. These techniques use different feedback schemes across the CCs, or allow some CCs to be un-reported, for the purpose of reducing the amount of feedback. Performance...

  15. Cooperative control of VSC-HVDC connected offshore wind farm with Low-Voltage Ride-Through capability

    DEFF Research Database (Denmark)

    Liu, Yan; Wang, Xiongfei; Chen, Zhe

    2012-01-01

    The Low-Voltage Ride-Through (LVRT) has become an important grid requirement for offshore wind farms connecting with Voltage Source Converter based High Voltage Direct Current (VSC-HVDC) links. In this paper, a cooperative control strategy with LVRT ability is proposed for a VSC-HVDC connected...

  16. NUG reliability implications in a composite generation and transmission system

    Energy Technology Data Exchange (ETDEWEB)

    Billinton, R.; Adzanu, S. [Saskatchewan Univ., Saskatoon, SK (Canada)

    1995-12-31

    The cost implications of non-utility generation (NUG) on composite generation and transmission system reliability was discussed and customer interruption costs in two test systems was reviewed. Reliability analysis based on generation, transmission and distribution with hierarchical levels (HL) was described. The Roy Billinton test system (RBTS) and the IEEE-Reliability test system were used for testing in conjunction with COMREL (COMposite system RELiability evaluation) software developed at the University of Saskatchewan. A description of COMREL, and best case results were presented for the RBTS. Assessment of energy costs for unserved energy accounted for the composite customer damage function (CCDF), interrupted energy assessment rate (IEAR), and expected energy not supplied (EENS) index. The utilization of reliability worth concepts was summarized, and was used to indicate different impacts on both load point and overall power system customer costs of unserved energy. It was concluded that quantitative reliability assessments can be performed in systems with NUGs, and that they can be extended to include reliability worth evaluations. 17 refs., 15 figs.

  17. Impedance Synthesis Based Vibration Analysis of Geared Transmission System

    Directory of Open Access Journals (Sweden)

    Yafeng Ren

    2017-01-01

    Full Text Available The severity of gear noise response depends on the sensitivity of geared rotor system dynamics to the transmission error. As gearbox design trending towards lighter weight and lower noise, the influence of housing compliance on system dynamic characteristics cannot be ignored. In this study, a gear-shaft-bearing-housing coupled impedance model is proposed to account for the effect of housing compliance on the vibration of geared transmission system. This proposed dynamic model offers convenient modeling, efficient computing, and ability to combine computed parameters with experimental ones. The numerical simulations on system dynamic characteristics are performed for both a rigid housing configuration and a flexible one. Natural frequencies, dynamic mesh forces, and dynamic bearing reaction loads are computed, and the housing compliance contribution on system dynamic characteristics is analyzed. Results show that increasing housing compliance will decrease the system natural frequencies and will affect the dynamic bearing reaction loads significantly but have very little influence on the dynamic mesh force. Also, the analysis shows that bearing stiffness has significant influence on the degree of housing contribution on system dynamic characteristics.

  18. Voltage control in the future power transmission systems

    DEFF Research Database (Denmark)

    Qin, Nan

    to ensure a highly reliable transmission, e.g. balancing the generation and the consumption in large geographic regions, the exchange capacities will be enlarged by upgrading the interconnections. The Danish power system, the electricity transportation hub between the Nordic and continental European systems......, driving by the market, is highly flexible. As more and more renewable energy integrating to the system, the voltage control in the future power system is becoming a challenging objective. This project considering the future challenges is to design a robust Automatic Voltage Control (AVC) system...... is strongly tractable for improving the robustness. In case the centralized AVC system is malfunctioning, e.g. telecommunications fails, the distributed fallback controllers will take the control responsibility to maintain the voltage in the acceptable band. The fallback scheme installed at substations...

  19. Lightning location system supervising Swedish power transmission network

    Science.gov (United States)

    Melin, Stefan A.

    1991-01-01

    For electric utilities, the ability to prevent or minimize lightning damage on personnel and power systems is of great importance. Therefore, the Swedish State Power Board, has been using data since 1983 from a nationwide lightning location system (LLS) for accurately locating lightning ground strikes. Lightning data is distributed and presented on color graphic displays at regional power network control centers as well as at the national power system control center for optimal data use. The main objectives for use of LLS data are: supervising the power system for optimal and safe use of the transmission and generating capacity during periods of thunderstorms; warning service to maintenance and service crews at power line and substations to end operations hazardous when lightning; rapid positioning of emergency crews to locate network damage at areas of detected lightning; and post analysis of power outages and transmission faults in relation to lightning, using archived lightning data for determination of appropriate design and insulation levels of equipment. Staff have found LLS data useful and economically justified since the availability of power system has increased as well as level of personnel safety.

  20. Real-time simulation of wind power plants with VSC-HVDC link for network integration studies

    Energy Technology Data Exchange (ETDEWEB)

    Le-Huy, Philippe; Tremblay, Olivier; Gagnon, Richard; Giroux, Pierre [Hydro-Quebec, Varennes, QC (Canada). Research Inst.

    2011-07-01

    As large wind power plants with voltage-source converter HVDC link projects sprout, many utilities will be faced with the need to simulate this tpe of system, offline and in real time, to develop, validate and tune control schemes and coordination protocols with other nearby power equipment. Adequate simulation tools are of the utmost importance to efficiently carry out these projects. This paper presents the latest work conducted at Hydro-Quebec's research institute to adapt its simulation tools to cope with such systems. Real-time capable models for aggregate type-IV wind turbines and voltage-source converters (modular multilevel and cascaded two-level converters) are presented and their use is illustrated with a typical wind power integration scenario. (orig.)

  1. Insulation Coordination of Arcing Horns on HVDC Electrode Lines: Protection Performance Evaluation, Influence Factors and Improvement Method

    Directory of Open Access Journals (Sweden)

    Xiandong Li

    2018-02-01

    Full Text Available Arcing horns are widely used in high voltage overhead lines to protect insulator strings from being destroyed by the free burning arcs caused by lightening faults. In this paper, we focus on the insulation coordination of arcing horns on the electrode lines of a 5000 MW, ±800 kV high voltage direct current (HVDC system. The protection performance of arcing horns are determined by the characteristics of not only the external system but also the fault arc. Therefore, the behaviors and characteristics of long free burning arcs are investigated by the experiments at first. In order to evaluate the protection performance of arcing horns, the static stability criterion U-I characteristic method is introduced. The influence factors on the protection performance of arcing horns are analyzed theoretically. Finally, the improvement methods for the protection performance of arcing horns are proposed, and the diversified configuration strategy of arcing horns is recommended for cost saving.

  2. Adaptive transmission schemes for MISO spectrum sharing systems

    KAUST Repository

    Bouida, Zied

    2013-06-01

    We propose three adaptive transmission techniques aiming to maximize the capacity of a multiple-input-single-output (MISO) secondary system under the scenario of an underlay cognitive radio network. In the first scheme, namely the best antenna selection (BAS) scheme, the antenna maximizing the capacity of the secondary link is used for transmission. We then propose an orthogonal space time bloc code (OSTBC) transmission scheme using the Alamouti scheme with transmit antenna selection (TAS), namely the TAS/STBC scheme. The performance improvement offered by this scheme comes at the expense of an increased complexity and delay when compared to the BAS scheme. As a compromise between these schemes, we propose a hybrid scheme using BAS when only one antenna verifies the interference condition and TAS/STBC when two or more antennas are illegible for communication. We first derive closed-form expressions of the statistics of the received signal-to-interference-and-noise ratio (SINR) at the secondary receiver (SR). These results are then used to analyze the performance of the proposed techniques in terms of the average spectral efficiency, the average number of transmit antennas, and the average bit error rate (BER). This performance is then illustrated via selected numerical examples. © 2013 IEEE.

  3. CAMEX-4 DC-8 INFORMATION COLLECTION AND TRANSMISSION SYSTEM V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The CAMEX-4 DC-8 Information Collection and Transmission System dataset was collected by the Information Collection and Transmission System (ICATS), which is...

  4. Multi-core Fibers in Submarine Networks for High-Capacity Undersea Transmission Systems

    DEFF Research Database (Denmark)

    Nooruzzaman, Md; Morioka, Toshio

    2017-01-01

    Application of multi-core fibers in undersea networks for high-capacity submarine transmission systems is studied. It is demonstrated how different architectures of submerged branching unit affect network component counts in long-haul undersea transmission systems......Application of multi-core fibers in undersea networks for high-capacity submarine transmission systems is studied. It is demonstrated how different architectures of submerged branching unit affect network component counts in long-haul undersea transmission systems...

  5. The WSTIAC Quarterly. Volume 9, Number 3

    Science.gov (United States)

    2010-01-25

    Control & Protection System Control & Protection System Shunt Capacitor Shunt Capacitor Sub-marine HVDC Transmission Cable Circuit Breaker...shows the other protective devices in the system . Some obvious advan- tages of a HVDC over HVAC transmission system are: 1. Economically cheaper—two...Smoothing reactors are employed to reduce ripples from the system in conjunction with DC. The layout of a HVDC

  6. Transmission of multiplexed video signals in multimode optical fiber systems

    Science.gov (United States)

    White, Preston, III

    1988-01-01

    Kennedy Space Center has the need for economical transmission of two multiplexed video signals along multimode fiberoptic systems. These systems must span unusual distances and must meet RS-250B short-haul standards after reception. Bandwidth is a major problem and studies of the installed fibers, available LEDs and PINFETs led to the choice of 100 MHz as the upper limit for the system bandwidth. Optical multiplexing and digital transmission were deemed inappropriate. Three electrical multiplexing schemes were chosen for further study. Each of the multiplexing schemes included an FM stage to help meet the stringent S/N specification. Both FM and AM frequency division multiplexing methods were investigated theoretically and these results were validated with laboratory tests. The novel application of quadrature amplitude multiplexing was also considered. Frequency division multiplexing of two wideband FM video signal appears the most promising scheme although this application requires high power highly linear LED transmitters. Futher studies are necessary to determine if LEDs of appropriate quality exist and to better quantify performance of QAM in this application.

  7. 77 FR 26275 - Bonneville Power Administration; Montana-to-Washington Transmission System Upgrade Project EIS

    Science.gov (United States)

    2012-05-03

    ... Bonneville Power Administration; Montana-to-Washington Transmission System Upgrade Project EIS AGENCY... (including wind generators and power marketers) requested the use of BPA's transmission system to transmit their power. To determine if BPA could offer the service requested, BPA studied the transmission system...

  8. Fault Diagnosis and Fault-tolerant Control of Modular Multi-level Converter High-voltage DC System

    DEFF Research Database (Denmark)

    Liu, Hui; Ma, Ke; Wang, Chao

    2016-01-01

    device fault, DC line faults as well as AC grid faults. Special attention is given to the comparison of the corresponding fault diagnosis and fault-tolerant control approaches. Further, focus is dedicated to control/protection strategies and topologies with fault ride-though capability for MMC...... of failures and lower the reliability of the MMC-HVDC system. Therefore, research on the fault diagnosis and fault-tolerant control of MMC-HVDC system is of great significance in order to enhance the reliability of the system. This paper provides a comprehensive review of fault diagnosis and fault handling...... strategies of MMC-HVDC systems for the most common faults happened in MMC-HVDC systems covering MMC faults, DC side faults as well as AC side faults. An important part of this paper is devoted to a discussion of the vulnerable spots as well as failure mechanism of the MMC-HVDC system covering switching...

  9. A portable wireless power transmission system for video capsule endoscopes.

    Science.gov (United States)

    Shi, Yu; Yan, Guozheng; Zhu, Bingquan; Liu, Gang

    2015-01-01

    Wireless power transmission (WPT) technology can solve the energy shortage problem of the video capsule endoscope (VCE) powered by button batteries, but the fixed platform limited its clinical application. This paper presents a portable WPT system for VCE. Besides portability, power transfer efficiency and stability are considered as the main indexes of optimization design of the system, which consists of the transmitting coil structure, portable control box, operating frequency, magnetic core and winding of receiving coil. Upon the above principles, the correlation parameters are measured, compared and chosen. Finally, through experiments on the platform, the methods are tested and evaluated. In the gastrointestinal tract of small pig, the VCE is supplied with sufficient energy by the WPT system, and the energy conversion efficiency is 2.8%. The video obtained is clear with a resolution of 320×240 and a frame rate of 30 frames per second. The experiments verify the feasibility of design scheme, and further improvement direction is discussed.

  10. ARQ schemes for data transmission in mobile radio systems

    Science.gov (United States)

    Comroe, R. A.; Costello, D. J., Jr.

    1984-01-01

    The problem of providing data communications over a land mobile radio channel is considered, taking into account error detection combined with retransmission on request as a means of obtaining reliability in digital data transmission. The considered systems are referred to as automatic RQ (repeat-request) or ARQ. It is pointed out that the distinguishing features of a land mobile radio (LMR) system, as far as the ARQ protocol is concerned, are a frequency or pair of frequencies shared by a large population of half-duplex users which cannot transmit and receive simultaneously. A description is presented of those variations of ARQ which are adaptable to an LMR system. A new channel model for a fading LMR channel is developed, and several ARQ protocols and some new protocol combinations are described. The relationships are developed for a description of the various protocols in terms of channel failure probabilities. Undetected error probabilities are developed and compared.

  11. Transmission of information between complex systems: 1/f resonance.

    Science.gov (United States)

    Aquino, Gerardo; Bologna, Mauro; West, Bruce J; Grigolini, Paolo

    2011-05-01

    We study the transport of information between two complex systems with similar properties. Both systems generate non-Poisson renewal fluctuations with a power-law spectrum 1/f(3-μ), the case μ=2 corresponding to ideal 1/f noise. We denote by μ(S) and μ(P) the power-law indexes of the system of interest S and the perturbing system P, respectively. By adopting a generalized fluctuation-dissipation theorem (FDT) we show that the ideal condition of 1/f noise for both systems corresponds to maximal information transport. We prove that to make the system S respond when μ(S)system S inherits the relaxation properties of the perturbing system. In the case where μ(P)>2, no response and no information transmission occurs in the long-time limit. We consider two possible generalizations of the fluctuation dissipation theorem and show that both lead to maximal information transport in the condition of 1/f noise.

  12. A flexible computerized system for environmental data acquisition and transmission

    Science.gov (United States)

    Zappalà, G.

    2009-04-01

    In recent years increasing importance has been addressed to the knowledge of the marine environment, either to help detecting and understanding global climate change phenomena, or to protect and preserve those coastal areas, where multiple interests converge (linked to the tourism, recreational or productive activities…) and which suffer greater impact from anthropogenic activities; this has in turn stimulated the start of research programs devoted to the monitoring and surveillance of these particular zones, coupling the needs for knowledge, sustainable development and exploitation of natural resources. There is an increasing need to have data available in real time or near real time in order to intervene in emergency situations. Cabled or wireless data transmission can be used. The first allows the transmission of a higher amount of data only in coastal sites, while the second gives a bigger flexibility in terms of application to different environments; more, using mobile phone services (either terrestrial or satellite), it is possible to allocate the data centre in the most convenient place, without any need of proximity to the sea. Traditional oceanographic techniques, based on ship surveys, hardly fit the needs of operational oceanography, because of their high cost and fragmentary nature, both in spatial and temporal domains. To obtain a good synopticity, it is necessary to complement traditional ship observations with measurements from fixed stations (buoys moored in sites chosen to be representative of wider areas, or to constitute a sentinel against the arrival of pollutants), satellite observations, use of ships of opportunity and of newly developed instruments, like the gliders, or towed sliding devices, like the SAVE. Modern instruments rely on an electronic heart; an integrated hardware-software system developed in Messina is here presented, used in various versions to control data acquisition and transmission on buoys or on ship

  13. Nonlinear Vibroimpact Characteristics of a Planetary Gear Transmission System

    Directory of Open Access Journals (Sweden)

    Jianxing Zhou

    2016-01-01

    Full Text Available In order to research the vibroimpact characteristics of a planetary gear transmission system under high speed and lightly loaded conditions, a new modeling method is proposed. In the modeling process, linear spring was used to simulate gear mesh elasticity under heavy load cases, and Hertz contact theory was used to calculate the contact force of gear pair under light load cases. Then, effects of the working conditions on the system vibroimpact characteristics are analyzed. The results show that, with input speed growing, the mesh force produced obvious fluctuations on the resonance frequencies of the sun gear and carrier torsion vibration, ring gear’s transverse vibration under the heavy load. Under light load condition, the collision vibration occurs in the gear pair; the changing trend of the contact force shows strongly nonlinear characteristics. The time of mesh-apart in gears pair decreases gradually as the load is increased; until it reaches collision vibration threshold value, the gear pair is no longer mesh-apart. With increasing of the input speed, the time of mesh-apart is decreased gradually; the fluctuation amplitude of contact force shows a linearly increasing trend. The study provides useful theoretical guideline for planetary gear transmission low-noise design.

  14. Aplanatic imaging systems for the transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Heiko, E-mail: mueller@ceos-gmbh.de [Corrected Electron Optical Systems GmbH, Englerstr. 28, D-69126 Heidelberg (Germany); Massmann, Ingo; Uhlemann, Stephan; Hartel, Peter; Zach, Joachim; Haider, Maximilian [Corrected Electron Optical Systems GmbH, Englerstr. 28, D-69126 Heidelberg (Germany)

    2011-07-21

    During the last decade aberration correctors have become a well-accepted tool in high-resolution transmission electron microscopy. The available correctors compensate for the spherical aberration C{sub s} of the imaging system. Recently, for instruments with considerably improved information limit also the off-axial aberrations have attracted more attention since these aberrations limit the high-resolution field of view. We have proposed a novel hexapole-type C{sub s}/B{sub 3}-corrector which corrects for the spherical aberration and the off-axial coma of the imaging system. We discuss the assessment and correction of off-axial aberrations and report about the optical performance of the first prototype instrument.

  15. Toroidal Continuously Variable Transmission Systems: Terminology and Present Studies

    Directory of Open Access Journals (Sweden)

    Ahmet YILDIZ

    2014-04-01

    Full Text Available The use of continuously variable transmission systems in many different areas such as aerospace, robotics, machinery and automotive industries as an alternative to conventional speed changers with constant ratio becomes widely.Especially in the automotive industry, these systems have been used increasingly, since they enable that internal combustion engines in vehicles run at optimal speeds, and consequently provide considerable fuel savings and therefore lower emission values and also they provide powerful acceleration and quiet working. CVT systems have several constructive variants such as belted, chained, balled, toroidal etc. In this paper, toroidal CVT systems based on elastohydrodynamic principles are concerned with, and fundamental works of last two decades in this field are reviewed. However, the relevant terminology and dynamics along with the control of these systems are briefly treated for better understanding of the literature mentioned. Attention is drawn to the lack of some significant issues in present research works, and potential future works are pointed out. This paper, to the authors’ knowledge, will be the first review on toroidal CVT systems in Turkish literature

  16. Risk measures for power failures in transmission systems

    Science.gov (United States)

    Cassidy, Alex; Feinstein, Zachary; Nehorai, Arye

    2016-11-01

    We present a novel framework for evaluating the risk of failures in power transmission systems. We use the concept of systemic risk measures from the financial mathematics literature with models of power system failures in order to quantify the risk of the entire power system for design and comparative purposes. The proposed risk measures provide the collection of capacity vectors for the components in the system that lead to acceptable outcomes. Keys to the formulation of our measures of risk are two elements: a model of system behavior that provides the (distribution of) outcomes based on component capacities and an acceptability criterion that determines whether a (random) outcome is acceptable from an aggregated point of view. We examine the effects of altering the line capacities on energy not served under a variety of networks, flow manipulation methods, load shedding schemes, and load profiles using Monte Carlo simulations. Our results provide a quantitative comparison of the performance of these schemes, measured by the required line capacity. These results provide more complete descriptions of the risks of power failures than the previous, one-dimensional metrics.

  17. Diagnostics of power transmissions system with tooth gear

    Directory of Open Access Journals (Sweden)

    Grzegorz WOJNAR

    2008-01-01

    Full Text Available This paper presents results of laboratory tests that were aimed at detecting early stages of various faults in toothed wheels by measurement and analysis of transverse vibration speed of the transmission gear shafts. In experimental investigation, cracking of the root tooth and chipping of the tooth were detected. The laser vibrometer Ometron VH300+ was used for non-contact measurement of shaft transversal vibration speed. Gear vibrations were recorded in selected points of gear housing and gear shafts at different speeds and gear loads. Results were analyzed and compared but in this paper is presented only selected examples. This paper shows that on the basis of the transverse vibration speed of transmission gear shafts, it is possible to detect defects at an earlier stage than on the basis of the housing vibration accelerations. In the case of measuring gear shaft vibration velocity, the way of the signal generated by the defect of a gear wheel (or bearing is shortened as well as the influence of composed transmittance of the bearing-gear housing system is eliminated. WV time-frequency analysis and complex continuous wavelet transformations were used for detection. The authors introduced a measure of local tooth damage, which was proportional to the size of damage. The results of research presented in this paperconfirmed that the defect's measure is very sensitive to the development of teeth faults.

  18. Transmission media appropriate laser-microwave solar power satellite system

    Science.gov (United States)

    Schäfer, C. A.; Gray, D.

    2012-10-01

    As a solution to the most critical problems with Solar power Satellite (SPS) development, a system is proposed which uses laser power transmission in space to a receiver high in the atmosphere that relays the power to Earth by either cable or microwave power transmission. It has been shown in the past that such hybrid systems have the advantages of a reduction in the mass of equipment required in geostationary orbit and avoidance of radio frequency interference with other satellites and terrestrial communications systems. The advantage over a purely laser power beam SPS is that atmospheric absorption is avoided and outages due to clouds and precipitation will not occur, allowing for deployment in the equatorial zone and guaranteeing year round operation. This proposal is supported by brief literature surveys and theoretical calculations to estimate crucial parameters in this paper. In relation to this concept, we build on a recently proposed method to collect solar energy by a tethered balloon at high altitude because it enables a low-cost start for bringing the first Watt of power to Earth giving some quick return on investment, which is desperately missing in the traditional SPS concept. To tackle the significant problem of GW-class SPSs of high launch cost per kg mass brought to space, this paper introduces a concept which aims to achieve a superior power over mass ratio compared to traditional satellite designs by the use of thin-film solar cells combined with optical fibres for power delivery. To minimise the aperture sizes and cost of the transmitting and receiving components of the satellite and high altitude receiver, closed-loop laser beam pointing and target tracking is crucial for pointing a laser beam onto a target area that is of similar size to the beam's diameter. A recently developed technique based on optical phase conjugation is introduced and its applicability for maintaining power transmission between the satellite and high altitude receiver is

  19. Transcutaneous Energy and Information Transmission System for a Totally-Implantable Artificial Heart

    Science.gov (United States)

    Tamura, Nozomi; Yamamoto, Takahiko; Aoki, Hirooki; Koshiji, Kohji; Homma, Akihiko; Tatsumi, Eisuke; Taenaka, Yoshiyuki

    In Totally-Implantable Artificial Heart (TAH) system, Transcutaneous Optical Information Transmission System (TOITS) and Externally Coupled Transcutaneous Energy Transmission System (ECTETS) are effective for driving, controlling and monitoring the TAH. Using these systems, a patient needs to wear an optical coupler and a transcutaneous transformer separately, and then the patient's QOL (Quality of Life) will be deteriorated. Therefore, we research the energy and information transmission by wearing an unified transcutaneous transformer. In this paper, the unified transcutaneous transformer for the energy and information transmission was investigated. As a result, the unified transformer, by which the coupling between the energy and information transmission was reduced, was developed.

  20. Capacitor voltage ripple reduction and arm energy balancing in MMC-HVDC

    DEFF Research Database (Denmark)

    Parikh, Harsh; Martin-Loeches, Ruben Sánches; Tsolaridis, Georgios

    2016-01-01

    Modular Multilevel Converters are emerging and widely used in HVDC applications. However, the submodule capacitors are still large and the energy balancing under unbalanced conditions is a challenge. In this paper, an analytical model focusing on the energy stored in the capacitors and voltage va...

  1. Connection of OWPPs to HVDC networks using VSCs and Diode Rectifiers: an Overview

    DEFF Research Database (Denmark)

    Saborío-Romano, Oscar; Bidadfar, Ali; Göksu, Ömer

    This paper provides an overview of two technologies for connecting offshore wind power plants (offshore WPPs, OWPPs) to high-voltage direct current (HVDC) networks: voltage source converters (VSCs) and diode rectifiers (DRs). Current grid code requirements for the connection of such power plants...

  2. Asymmetrical Fault Analysis at the Offshore Network of HVDC connected Wind Power Plants

    DEFF Research Database (Denmark)

    Goksu, Omer; Cutululis, Nicolaos Antonio; Sorensen, Poul

    2017-01-01

    Short-circuit faults for HVDC connected Wind Power Plants (WPPs) have been studied mostly for dc link and onshore ac grid faults, while the offshore ac faults, especially asymmetrical faults, have been mostly omitted in the literature. Requirements related to the offshore asymmetrical faults have...

  3. HVDC Connected Offshore Wind Power Plants: Review and Outlook of Current Research

    DEFF Research Database (Denmark)

    Glasdam, Jakob Bærholm; Zeni, Lorenzo; Gryning, Mikkel

    2013-01-01

    This paper presents a state-of-the-art review on grid integration of large offshore wind power plants (OWPPs) using high voltage direct voltage (HVDC) for grid connection. The paper describes in detail selected challenges hereto and presents how DONG Energy Wind Power (DEWP) is addressing these c...

  4. Harmonic Stability Studies in VSC-HVDC Grid Connected Offshore Wind Power Plants

    DEFF Research Database (Denmark)

    Glasdam, Jakob Bærholm; Gevorgian, Vahan; Bak, Claus Leth

    2017-01-01

    Converter rich grids such as offshore wind power plants (OWPPs) are prone to become unstable due to control interaction with e.g. the extensive sub-marine cabling. There exists a need to investigate the stability in high voltage direct current (HVDC)grid connected OWPPs, as the electrical...

  5. HVDC Connected Offshore Wind Power Plants: Review and Outlook of Current Research

    DEFF Research Database (Denmark)

    Glasdam, Jakob; Zeni, Lorenzo; Gryning, Mikkel

    2013-01-01

    these challenges through three coordinated PhD projects in close collaboration with leading academia within the field. The overall goal of these projects is to acquire in-depth knowledge of relevant operating phenomena in the offshore OWPP grid, rich with power electronics devices (PEDs) such as the HVDC...

  6. Forming the Calculated Dynamic Transmission Systems of Wheeled Vehicles

    Directory of Open Access Journals (Sweden)

    A. B. Fominykh

    2017-01-01

    Full Text Available To calculate dynamic loading of transmission parts of wheeled vehicles, it is necessary to build up the appropriate calculated dynamic systems and determine their inertial, elastic, and damping parameters.The initial point of this process is to form an initial dynamic system. Hereafter, to cut the time of computations there is a need to reduce the number of masses of this system, and sometimes simplify its structure. The main requirement to be fulfilled in this case is that the calculated dynamical system is to be equivalent to the initial one (in terms of similarity of the vibrational process characteristics in these systems, i.e., the frequencies and modes of oscillations of both systems, their amplitude-frequency characteristics. This is possible when the energy characteristics of the corresponding systems are equal, i.e. their kinetic and potential energies, dissipative functions, and external force energies.Usually, when forming the initial and calculated dynamic systems, all types of friction are reduced to a linearly viscous one. However, it disables us to investigate the motion of these systems if there is an arbitrary, in particular, poly-harmonic action (for example, on the side of the internal combustion engine, since in this case the linear friction coefficients given will depend on the frequency and amplitude of the oscillations.The paper is aimed at determining the equivalent parameters of calculated dynamic systems of wheeled vehicles, including the dissipative parameters for the general case of friction.On the basis of energy principles, the expressions are obtained to determine the equivalent inertial, elastic, and damping parameters of the calculated dynamical systems of wheeled vehicles when the structure is changed and the number of masses of the system is decreased. The presented technique enables us to investigate the motion of these systems under arbitrary, including poly-harmonic, action on the system, using the

  7. Vibration Signature Analysis of a Faulted Gear Transmission System

    Science.gov (United States)

    Choy, F. K.; Huang, S.; Zakrajsek, J. J.; Handschuh, R. F.; Townsend, D. P.

    1996-01-01

    A comprehensive procedure in predicting faults in gear transmission systems under normal operating conditions is presented. Experimental data were obtained from a spiral bevel gear fatigue test rig at NASA/Lewis. Time-synchronous-averaged vibration data were recorded throughout the test as the fault progressed from a small single pit to severe pitting over several teeth, and finally tooth fracture. A numerical procedure based on the Wigner-Ville distribution was used to examine the time-averaged vibration data. Results from the Wigner-Ville procedure are compared to results from a variety of signal analysis techniques that include time-domain analysis methods and frequency analysis methods. Using photographs of the gear tooth at various stages of damage, the limitations and accuracy of the various techniques are compared and discussed. Conclusions are drawn from the comparison of the different approaches as well as the applicability of the Wigner-Ville method in predicting gear faults.

  8. Vibration and noise analysis of a gear transmission system

    Science.gov (United States)

    Choy, F. K.; Qian, W.; Zakrajsek, J. J.; Oswald, F. B.

    1993-01-01

    This paper presents a comprehensive procedure to predict both the vibration and noise generated by a gear transmission system under normal operating conditions. The gearbox vibrations were obtained from both numerical simulation and experimental studies using a gear noise test rig. In addition, the noise generated by the gearbox vibrations was recorded during the experimental testing. A numerical method was used to develop linear relationships between the gearbox vibration and the generated noise. The hypercoherence function is introduced to correlate the nonlinear relationship between the fundamental noise frequency and its harmonics. A numerical procedure was developed using both the linear and nonlinear relationships generated from the experimental data to predict noise resulting from the gearbox vibrations. The application of this methodology is demonstrated by comparing the numerical and experimental results from the gear noise test rig.

  9. On multiuser switched diversity transmission for spectrum sharing systems

    KAUST Repository

    Qaraqe, Marwa

    2012-01-01

    In this paper, we develop multiuser access schemes for spectrum sharing systems whereby secondary users share the spectrum with primary users. In particular, we devise two schemes for selecting the user among those that satisfy the interference constraints and achieve an acceptable signal-to-noise ratio (SNR) level. The first scheme selects the user with the maximum SNR at the receiver, whereas in the second scheme the users are scanned in a sequential manner until an acceptable user is found. In addition, we consider two power adaptive settings. In the on/off power adaptive setting, the users transmit based on whether the interference constraint is met or not while in the full power adaptive setting, the users vary their transmission power to satisfy the interference constraint. Finally, we present numerical results of our proposed algorithms where we show the trade-off between the average spectral efficiency and average feedback load of both schemes. © 2012 ICST.

  10. Transmission imaging for integrated PET-MR systems

    Science.gov (United States)

    Bowen, Spencer L.; Fuin, Niccolò; Levine, Michael A.; Catana, Ciprian

    2016-08-01

    Attenuation correction for PET-MR systems continues to be a challenging problem, particularly for body regions outside the head. The simultaneous acquisition of transmission scan based μ-maps and MR images on integrated PET-MR systems may significantly increase the performance of and offer validation for new MR-based μ-map algorithms. For the Biograph mMR (Siemens Healthcare), however, use of conventional transmission schemes is not practical as the patient table and relatively small diameter scanner bore significantly restrict radioactive source motion and limit source placement. We propose a method for emission-free coincidence transmission imaging on the Biograph mMR. The intended application is not for routine subject imaging, but rather to improve and validate MR-based μ-map algorithms; particularly for patient implant and scanner hardware attenuation correction. In this study we optimized source geometry and assessed the method’s performance with Monte Carlo simulations and phantom scans. We utilized a Bayesian reconstruction algorithm, which directly generates μ-map estimates from multiple bed positions, combined with a robust scatter correction method. For simulations with a pelvis phantom a single torus produced peak noise equivalent count rates (34.8 kcps) dramatically larger than a full axial length ring (11.32 kcps) and conventional rotating source configurations. Bias in reconstructed μ-maps for head and pelvis simulations was  ⩽4% for soft tissue and  ⩽11% for bone ROIs. An implementation of the single torus source was filled with 18F-fluorodeoxyglucose and the proposed method quantified for several test cases alone or in comparison with CT-derived μ-maps. A volume average of 0.095 cm-1 was recorded for an experimental uniform cylinder phantom scan, while a bias of  <2% was measured for the cortical bone equivalent insert of the multi-compartment phantom. Single torus μ-maps of a hip implant phantom showed significantly less

  11. Asymmetric operation of AC power transmission systems : the key to optimizing power system reliability and economics

    Energy Technology Data Exchange (ETDEWEB)

    Marceau, R.J. [University of Ontario Inst. of Technology, Oshawa, ON (Canada); McGillis, D.T. [McGill Univ., Montreal, PQ (Canada). Dept. of Electrical and Computer Engineering]|[Concordia Univ., Montreal, PQ (Canada). Dept. of Electrical and Computer Engineering; Sana, A.R.

    2006-07-01

    This book provides an invaluable tool for professionals working in the field of electrical engineering and applied science. It presents a simple and cost-effective strategy to operate alternating current (AC) power transmission systems more reliably and economically. Typically, bulk power transmission systems are operated symmetrically. When a problem such as a short-circuit occurs on a 3-phase line on an individual phase, all 3 phases are taken out of service. Such a strategy is fundamentally inefficient, given that most faults are single-line-to-ground faults. The more effective operating strategy presented in this book is based on the concept of asymmetric operation, which defines the operation of a 3-phase AC transmission line as 3 independently operated entities. As such, a 3-phase line can be operated with 1 or 2 phases out of service for single-line transmission corridors or with 1 , 2 or 3 phases out of service in the case of multiple-line corridors. This approach also maintains 3-phase symmetrical operation at its extremities, thereby protecting loads and power plants from undesirable voltages and currents. The overall integrity of 3-phase transmission is maintained in terms of power delivery, balanced voltages and currents even in the event of failures in part of the transmission system. The result is improved security. 67 refs., 42 tabs., 73 figs., 2 appendices.

  12. Location optimization of remote gain unit in ultralong span repeaterless optical transmission system

    Science.gov (United States)

    Xiong, Huang; Shan, Yuanyuan; Sun, Junqiang

    2017-03-01

    The influences of the remote gain unit (RGU) location on ultralong span repeaterless optical transmission system with different bit rates and the number of the signal channels is discussed in this paper. The experimental results show that the optimal location of the RGU can always exist for obtaining the minimum signal bit error rate at receiver with a fixed transmission distance. The optimization location of the RGU is entirely dependent on the total transmission length and the number of channel in the wavelength division multiplexing (WDM) system. When the 1480-nm pump power is set about 1 W, the span of the repeaterless WDM transmission system can be extended to 402 km through optimizing the location of the RGU. The optimal configuration scheme of the RGU can provide a potential application to increase the transmission spans for undersea transmission systems, electric power transmission systems, and the other special trades.

  13. Application of new directional logic to improve DC side fault discrimination for high resistance faults in HVDC grids

    National Research Council Canada - National Science Library

    HALEEM, Naushath M; RAJAPAKSE, Athula D

    2017-01-01

    .... The proposed protection scheme is applied to a multi-level modular converter based three-terminal HVDC grid and its security and sensitivity are evaluated through electromagnetic transient simulations...

  14. The Diagnostic System of A – 604 Automatic Transmission

    Directory of Open Access Journals (Sweden)

    Czaban Jaroslaw

    2014-09-01

    Full Text Available Automatic gearbox gains increasing popularity in Europe. Little interest in diagnosis of such type of transmission in Poland results from the fact of small share in the whole market of operated cars, so there is a lack of availability of special diagnostic devices. These factors cause issues of expensive repairs, often involving a replacement of subassembly to new or aftermarket one. To a small extent some prophylactic diagnostic tests are conducted, which can eliminate future gearbox system failures. In the paper, the proposition of diagnostic system of popular A - 604 gearbox was presented. The authors are seeking for the possibility of using such type of devices to functional elaboration of gearboxes after renovation. The built system pursues the drive of the researched object, connected with simulated load, where special controller, replacing the original one, is responsible for controlling gearbox operation. This way is used to evaluate the mechanic and hydraulic parts' state. Analysis of signal runs, registered during measurements lets conclude about operation correctness, where as comparison with stock data verifies the technical state of an automatic gearbox.

  15. Transmissibility of the monkeypox virus clades via respiratory transmission: investigation using the prairie dog-monkeypox virus challenge system.

    Directory of Open Access Journals (Sweden)

    Christina L Hutson

    Full Text Available Monkeypox virus (MPXV is endemic within Africa where it sporadically is reported to cause outbreaks of human disease. In 2003, an outbreak of human MPXV occurred in the US after the importation of infected African rodents. Since the eradication of smallpox (caused by an orthopoxvirus (OPXV related to MPXV and cessation of routine smallpox vaccination (with the live OPXV vaccinia, there is an increasing population of people susceptible to OPXV diseases. Previous studies have shown that the prairie dog MPXV model is a functional animal model for the study of systemic human OPXV illness. Studies with this model have demonstrated that infected animals are able to transmit the virus to naive animals through multiple routes of exposure causing subsequent infection, but were not able to prove that infected animals could transmit the virus exclusively via the respiratory route. Herein we used the model system to evaluate the hypothesis that the Congo Basin clade of MPXV is more easily transmitted, via respiratory route, than the West African clade. Using a small number of test animals, we show that transmission of viruses from each of the MPXV clade was minimal via respiratory transmission. However, transmissibility of the Congo Basin clade was slightly greater than West African MXPV clade (16.7% and 0% respectively. Based on these findings, respiratory transmission appears to be less efficient than those of previous studies assessing contact as a mechanism of transmission within the prairie dog MPXV animal model.

  16. Use of flexible alternating current transmission systems (facts) to ...

    African Journals Online (AJOL)

    ... network are sluggish and mechanical controlled and do not satisfy rapid changes in transmission network parameters. It identified areas in the network with low voltages and high power losses where FACTS devices can be injected in the Nigeria 330KV lines to increase transmission capabilities and boost power output to ...

  17. Calculation of Achievable Information Rates of Long-Haul Optical Transmission Systems Using Instanton Approach

    Science.gov (United States)

    Ivković, Miloš; Djordjević, Ivan; Vasić, Bane

    2007-05-01

    A method for estimation of achievable information rates of high-speed optical transmission systems is proposed. This method consists of two steps: 1) approximating probability density functions for energy of pulses, which is done by the instanton approach, and 2) estimating achievable information rates by applying a method originally proposed by Arnold and Pfitser. Numerical results for a specific optical transmission system (submarine system at transmission rate 40 Gb/s) are reported.

  18. Design of a data transmission system based on gigabit ethernet

    Science.gov (United States)

    Yuan, Yongxin; Zhang, Lijun; Xu, Bin; Wang, Jiqiang; Yuan, Yonggang

    2013-09-01

    FPGA(Field-programmable gate array) is programmable device, characterized by high speed and reconfiguration. We could test the circuit programmed by HDL (Hardware Description Language). By observing results of simulations through ModelSim, developers could fix logic errors. Also, they could analyze performance of circuits by the results. In the system, we build the Gigabit Ethernet development platform based on a FPGA. This paper presents the technique of FPGA and Gigabit Ethernet, as well as relevant techniques. On the basis of merits and drawbacks of different design proposals and real demands, we take the EP3C10E144C8N chip belonging to the series of Cyclone III produced by Altera corp. as main controller chip. By the use of an AX88180 MAC chip produced by ASIX Electronics Corporation and a RTL8211E physical chip by Realtek Semiconductor Corporation, we build the development platform. At the receiving end, we capture data frames from the network adapter by winpcap programming and throw video data in the buffer. Considering large amounts of data in the real-time transportation, we design fixed-length queue as the primary structures for buffer. Size of a buffer unit is 32KB, which means that 32 packets can fill the buffer. When the buffer is full, we put the buffer unit to the end of the queue. We get data from buffer and hand it over to application process to display and store video data. When packet loss is detected by the system, log file will record it and thus we can check how many packets lose. The simulations by Quartus II and practical application proves that the system is stable, featuring high speed and low cost. It can be used in various high speed real-time transmission with little modification.

  19. Transcutaneous Energy and Information Transmission System for a Totally Implantable Artificial Heart

    Science.gov (United States)

    Tamura, Nozomi; Yamamoto, Takahiko; Aoki, Hirooki; Koshiji, Kohji; Homma, Akihiko; Tatsumi, Eisuke; Taenaka, Yoshiyuki

    In Totally-Implantable Artificial Heart(TAH) system, Transcutaneous Optical Information Transmission System(TOITS) and Externally Coupled Transcutaneous Energy Transmission System(ECTETS) are effective for driving, controlling and monitoring the TAH. Using these systems, a patient needs to wear an optical coupler and a transcutaneous transformer separately, and then the patient's QOL (Quality of Life) will be deteriorated. In this paper, for improving the QOL, the energy and information transmission using an unified transcutaneous transformer was investigated, and their information transmission characteristics were evaluated.

  20. Polar On-Line Acquisition Relay and Transmission System (POLARATS)

    Energy Technology Data Exchange (ETDEWEB)

    Yuracko, K.

    2004-07-15

    POLARATS (Polar On-Line Acquisition Relay And Transmission System) is being developed by YAHSGS LLC (YAHSGS) and Oak Ridge National Laboratory (ORNL) to provide remote, unattended monitoring of environmental parameters under harsh environmental conditions. In particular, instrumental design and engineering is oriented towards protection of human health in the Arctic, and with the additional goal of advancing Arctic education and research. POLARATS will obtain and transmit environmental data from hardened monitoring devices deployed in locations important to understanding atmospheric and aquatic pollutant migration as it is biomagnified in Arctic food chains. An Internet- and personal computer (PC)-based educational module will provide real time sensor data, on-line educational content, and will be integrated with workbooks and textbooks for use in middle and high school science programs. The educational elements of POLARATS include an Internet-based educational module that will instruct students in the use of the data and how those data fit into changing Arctic environments and food chains. POLARATS will: (1) Enable students, members of the community, and scientific researchers to monitor local environmental conditions in real time over the Internet; and (2) Provide additional educational benefits through integration with middle- and high-school science curricula. Information will be relayed from POLARATS devices to classrooms and libraries along with custom-designed POLARATS teaching materials that will be integrated into existing curricula to enhance the educational benefits realized from the information obtained.

  1. Smart Grid Wide-Area Transmission System Visualization

    Directory of Open Access Journals (Sweden)

    Thomas J. Overbye

    2015-12-01

    Full Text Available The installation of vast quantities of additional new sensing and communication equipment, in conjunction with building the computing infrastructure to store and manage data gathered by this equipment, has been the first step in the creation of what is generically referred to as the “smart grid” for the electric transmission system. With this enormous capital investment in equipment having been made, attention is now focused on developing methods to analyze and visualize this large data set. The most direct use of this large set of new data will be in data visualization. This paper presents a survey of some visualization techniques that have been deployed by the electric power industry for visualizing data over the past several years. These techniques include pie charts, animation, contouring, time-varying graphs, geographic-based displays, image blending, and data aggregation techniques. The paper then emphasizes a newer concept of using word-sized graphics called sparklines as an extremely effective method of showing large amounts of time-varying data.

  2. 21 CFR 26.43 - Transmission of quality system evaluation reports.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Transmission of quality system evaluation reports... QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN MEDICAL DEVICE PRODUCT EVALUATION REPORTS: UNITED STATES AND THE EUROPEAN COMMUNITY Specific Sector Provisions for Medical Devices § 26.43 Transmission of quality system...

  3. 75 FR 3223 - California Independent System Operator Corporation; Midwest Independent Transmission System...

    Science.gov (United States)

    2010-01-20

    ... the responsiveness of regional transmission organizations (RTOs) and independent system operators... the stakeholder process. In addition to the proposals made by NASUCA, other commenters argue that RTOs... opportunity to further explore these concerns and proposals with the parties and the RTOs and ISOs. These...

  4. Line Capacity Expansion and Transmission Switching in Power Systems With Large-Scale Wind Power

    DEFF Research Database (Denmark)

    Villumsen, Jonas Christoffer; Bronmo, Geir; Philpott, Andy B.

    2013-01-01

    In 2020 electricity production from wind power should constitute nearly 50% of electricity demand in Denmark. In this paper we look at optimal expansion of the transmission network in order to integrate 50% wind power in the system, while minimizing total fixed investment cost and expected cost...... of power generation. We allow for active switching of transmission elements to reduce congestion effects caused by Kirchhoff's voltage law. Results show that actively switching transmission lines may yield a better utilization of transmission networks with large-scale wind power and increase wind power...... penetration. Furthermore, it is shown that transmission switching is likely to affect the optimal line capacity expansion plan....

  5. Study for wireless power transmission of nuclear robot system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jongseog [Central Research Institute of Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of)

    2013-05-15

    Gasoline engine or electric motor is generally used for driving power of working. Gasoline tank is uncomfortable to carry. Battery capacity does not sustain long time working. Frequent moving back of robot to power charger or refueling tank is inconvenient. Long power cable connection occur winding problem if there are complex structures in walking way. We need some solution for continuous supply of robot energy at the free moving condition of robot. 'Wireless power transmission' is one of the solutions. Some experiment result to transmit wireless power to moving robot is described herein. To find possible wireless power transmission method for nuclear robot, wireless power transmission tests were performed. As result of these tests, it was confirmed that wireless power transmission by using dipole and mat type magnetic induction were possible. As result of flying robot experiment, it was realized that development of light weight core for receiver and wave reflection device for high directional transmitter are necessary for practical use of the dipole type wireless power transmission. Small size core and high directional transmitter will be next target. Mat type wireless power transmission is regarded as useful for robot power charging station in the inside containment.

  6. Transient Stability Assessment of Power System with Large Amount of Wind Power Penetration

    DEFF Research Database (Denmark)

    Liu, Leo; Chen, Zhe; Bak, Claus Leth

    2012-01-01

    Recently, the security and stability of power system with large amount of wind power are the concerned issues, especially the transient stability. In Denmark, the onshore and offshore wind farms are connected to distribution system and transmission system respectively. The control and protection...... plants, load consumption level and high voltage direct current (HVDC) transmission links are taken into account. The results presented in this paper are able to provide an early awareness of power system security condition of the western Danish power system....... methodologies of onshore and offshore wind farms definitely affect the transient stability of power system. In this paper, the onshore and offshore wind farms are modeled in detail in order to assess the transient stability of western Danish power system. Further, the computation of critical clearing time (CCT...

  7. Impact of Distributed Generation on the Voltage Sag Performance of Transmission Systems

    Directory of Open Access Journals (Sweden)

    Pierluigi Caramia

    2017-07-01

    Full Text Available In this paper, we analysed the growing penetration of generating units from renewable energy sources in transmission power systems. Among the possible effects of the interaction of distributed generation (DG with transmission systems, we considered the abnormal operating conditions caused by short circuits in the transmission systems and the resulting voltage sags that occur in the network. A systematic method is presented for analysing the voltage sag behaviour of any transmission system in which large DG units are connected to the transmission system by means of High Voltage/Medium Voltage (HV/MV stations. The method proposed for obtaining the voltage sags is the fault position method (FPM, from which we derived a graphical visualization of the during-fault voltage (DFV matrix as a valuable tool to obtain an immediate measure of the propagation of voltage sags in the network. The results obtained were based on a portion of a real transmission system. The system that we considered is an actual portion of the Italian transmission system, and all of the quantities we used were obtained from the data of the Transmission system operator (TSO.

  8. Transmission of high power sensor system and DWDM data system in one optical fiber

    OpenAIRE

    Čučka, Milan; Münster, Petr; Kočí, Lukáš; Horváth, Tomáš; Filka, Miloslav; Vojtěch, Josef

    2016-01-01

    The main contribution of this paper is simulation of transmission DWDM system and high power sensor system in one optical fiber Hlavním přínosem této práce je simulace přenosu DWDM systému a vysokovýkonového senzorického systému na jednom optickém vlákně.

  9. Experimental characterization of dispersion maps with Raman gain in 160 Gb/s transmission systems

    DEFF Research Database (Denmark)

    Zhenbo, Xu; Seoane, Jorge; Siahlo, Andrei

    2004-01-01

    We investigate the combined effects of dispersion compensation and Raman amplification in SMF-based transmission span of 160 Gb/s system. The post compensation map shows better power tolerance.......We investigate the combined effects of dispersion compensation and Raman amplification in SMF-based transmission span of 160 Gb/s system. The post compensation map shows better power tolerance....

  10. Insulation coordination for lightning overvoltages on a long HVDC submarine cable

    Energy Technology Data Exchange (ETDEWEB)

    Mader, D.J.

    1993-01-01

    This paper demonstrates by detailed modelling and simulation a statistical approach to determining the lightning-induced overvoltage stresses on the insulation of a 220 km HVDC submarine cable due to lightning strikes to the overhead line, and explores methods of controlling these overvoltages to levels that will allow lightning impulse withstand levels as low as 2.0 per unit of working voltage with an adequate safety margin.

  11. Performance analysis for optimum transmission and comparison with maximal ratio transmission for MIMO systems with cochannel interference

    Directory of Open Access Journals (Sweden)

    Lin Sheng-Chou

    2011-01-01

    Full Text Available Abstract This article presents the performance analysis of multiple-input/multiple-output (MIMO systems with quadrature amplitude modulation (QAM transmission in the presence of cochannel interference (CCI in nonfading and flat Rayleigh fading environments. The use of optimum transmission (OT and maximum ratio transmission (MRT is considered and compared. In addition to determining precise results for the performance of QAM in the presence of CCI, it is our another aim in this article to examine the validity of the Gaussian interference model in the MRT-based systems. Nyquist pulse shaping and the effects of cross-channel intersymbol interference produced by CCI due to random symbol of the interfering signals are considered in the precise interference model. The error probability for each fading channel is estimated fast and accurately using Gauss quadrature rules which can approximate the probability density function (pdf of the output residual interference. The results of this article indicate that Gaussian interference model may overestimate the effects of interference, particularly, for high-order MRT-based MIMO systems over fading channels. In addition, OT cannot always outperform MRT due to the significant noise enhancement when OT intends to cancel CCI, depending on the combination of the antennas at the transmitter and the receiver, number of interference and the statistical characteristics of the channel.

  12. Carbon footprint of the Danish electricity transmission and distribution systems

    DEFF Research Database (Denmark)

    Turconi, Roberto; Astrup, Thomas Fruergaard

    , and relevant auxiliary infrastructures. Electricity T&D provided respectively 29 and 17 gCO2e/kWh, mainly related to power losses. Emissions from distribution were larger than those from transmission, because of higher losses and higher complexity and material consumption. Large differences were found between......The electricity sector is among the main sources of greenhouse gas (GHG) emissions; today, those are mainly due to combustion of fossil fuels, but with increasing renewable sources the importance of infrastructures both in electricity generation and in transmission and distribution (T......&D) will likely grow. Several studies are available on renewable energy technologies, but only a few on transmission of electricity, and none on its distribution. This study provides life cycle inventory data for electricity distribution networks, and a life cycle GHG accounting of the Danish T&D networks...

  13. Virtual Pipeline System Testbed to Optimize the U.S. Natural Gas Transmission Pipeline System

    Energy Technology Data Exchange (ETDEWEB)

    Kirby S. Chapman; Prakash Krishniswami; Virg Wallentine; Mohammed Abbaspour; Revathi Ranganathan; Ravi Addanki; Jeet Sengupta; Liubo Chen

    2005-06-01

    The goal of this project is to develop a Virtual Pipeline System Testbed (VPST) for natural gas transmission. This study uses a fully implicit finite difference method to analyze transient, nonisothermal compressible gas flow through a gas pipeline system. The inertia term of the momentum equation is included in the analysis. The testbed simulate compressor stations, the pipe that connects these compressor stations, the supply sources, and the end-user demand markets. The compressor station is described by identifying the make, model, and number of engines, gas turbines, and compressors. System operators and engineers can analyze the impact of system changes on the dynamic deliverability of gas and on the environment.

  14. Non-systemic transmission of tick-borne diseases: A network approach

    Science.gov (United States)

    Ferreri, Luca; Bajardi, Paolo; Giacobini, Mario

    2016-10-01

    Tick-borne diseases can be transmitted via non-systemic (NS) transmission. This occurs when tick gets the infection by co-feeding with infected ticks on the same host resulting in a direct pathogen transmission between the vectors, without infecting the host. This transmission is peculiar, as it does not require any systemic infection of the host. The NS transmission is the main efficient transmission for the persistence of the tick-borne encephalitis virus in nature. By describing the heterogeneous ticks aggregation on hosts through a bipartite graphs representation, we are able to mathematically define the NS transmission and to depict the epidemiological conditions for the pathogen persistence. Despite the fact that the underlying network is largely fragmented, analytical and computational results show that the larger is the variability of the aggregation, and the easier is for the pathogen to persist in the population.

  15. Transmission Needs In A Fully Renewable Pan-European Electricity System

    DEFF Research Database (Denmark)

    Rodriguez, Rolando A.; Bruun Andresen, Gorm; Becker, Sarah

    2012-01-01

    Based on high-resolution weather and electrical load data, the transmission needs for a fully renewable pan-European electricity system are determined. The ideal cross-border transmission capacities turn out to be a factor 10 larger than those of today. A reduction of cross-border transmission ca...... capacities lead to a non-linear increase of balancing needs. A good compromise turns out to be a capacity layout, which is a factor 5 larger than today’s one. On average each country will only be able to import / export 40% of its residual demand / renewable excess generation.......Based on high-resolution weather and electrical load data, the transmission needs for a fully renewable pan-European electricity system are determined. The ideal cross-border transmission capacities turn out to be a factor 10 larger than those of today. A reduction of cross-border transmission...

  16. Initial assessment: electromagnetic compatibility aspects of proposed SPS Microwave Power Transmission System (MPTS) operations

    Energy Technology Data Exchange (ETDEWEB)

    1978-02-01

    An analysis of major concerns with regard to the effects on radio and electronic systems by the proposed Microwave Power Transmission System for transmitting power from a satellite solar power station to earth is presented. (LCL)

  17. High Voltage AC underground cable systems for power transmission

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Silva, Filipe Miguel Faria da

    2016-01-01

    This paper is a first of two presenting a review of research results in underground cable transmission obtained by the Department of Energy Technology, Aalborg University ET/AAU and Danish TSO Energinet.dk within the last 6 years. The main core of the results are obtained by PhD students research...

  18. High Voltage AC underground cable systems for power transmission

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Silva, Filipe Miguel Faria da

    2016-01-01

    This paper is a second of two presenting a review of research results in underground cable transmission obtained by the Department of Energy Technology, Aalborg University ET/AAU and Danish TSO Energinet.dk within the last six years. The main core of the results are obtained by PhD students resea...

  19. A low cost data logging system with satellite transmission capabilities

    Digital Repository Service at National Institute of Oceanography (India)

    Desa, E.S.; DeSa, E.J.; Desai, R.G.P.

    The concept of updating a shore based data bank by regular satellite transmissions of data collected at sea has important uses in programmes on the exploration and survey of sea bed mineral sites. In this context, the need arose to log data from a...

  20. 77 FR 4292 - Midwest Independent Transmission System Operator, Inc.; Notice of Filing of Response to Data Request

    Science.gov (United States)

    2012-01-27

    ... Energy Regulatory Commission Midwest Independent Transmission System Operator, Inc.; Notice of Filing of Response to Data Request Take notice that on January 19, 2012, Midwest Independent Transmission System... representatives of Transmission Owners and Non-Transmission Owners, MISO Advisory Committee participants, and all...

  1. Analysis of transmission efficiency of the superconducting resonance coil according the materials of cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yu Kyeong; Hwang, Jun Won; Choi, Hyo Sang [Chosun University, Gwangju (Korea, Republic of)

    2016-03-15

    The wireless power transfer (WPT) system using a magnetic resonance was based on magnetic resonance coupling of the transmission and the receiver coils. In these system, it is important to maintain a high quality-factor (Q-factor) to increase the transmission efficiency of WPT system. Our research team used a superconducting coil to increase the Q-factor of the magnetic resonance coil in WPT system. When the superconductor is applied in these system, we confirmed that transmission efficiency of WPT system was higher than normal conductor coil through a preceding study. The efficiency of the transmission and the receiver coil is affected by the magnetic shielding effect of materials around the coils. The magnetic shielding effect is dependent on the type, thickness, frequency, distance, shape of materials. Therefore, it is necessary to study the WPT system on the basis of these conditions. In this paper, the magnetic shield properties of the cooling system were analyzed using the High-Frequency Structure Simulation (HFSS, Ansys) program. We have used the shielding materials such as plastic, aluminum and iron, etc. As a result, when we applied the fiber reinforced polymer (FRP), the transmission efficiency of WPT was not affected because electromagnetic waves went through the FRP. On the other hand, in case of a iron and aluminum, transmission efficiency was decreased because of their electromagnetic shielding effect. Based on these results, the research to improve the transmission efficiency and reliability of WPT system is continuously necessary.

  2. Desk study of CSFR: Power-transmission system. Export trade information

    Energy Technology Data Exchange (ETDEWEB)

    1992-06-01

    The Slovak Energy Production Company (SEP) is currently evaluating the rehabilitation/modernization of its generating plants. These generation source changes will significantly impact the SEP transmission system. In recognition of this, SEP has submitted to the U.S. Trade and Development Program (TDP) a package of five specific proposals related to the evaluation of transmission system upgrades, modernizations, and additions. They include: Evaluate generation source changes and additions and their impact on the SEP transmission system; Evaluate for upgrade the existing transmission lines; Evaluate upgrades and modernizations to bring SEP substations up to state-of-the-art; Evaluate new 400 kV line additions; and Feasibility study of new system generation/transmission control dispatch center at Zilina. A Desk Study of the technical, economic, and financial prospects of the submitted proposal package was commissioned by TDP. As part of the Desk Study, an evaluation of the export potential for U.S. goods and services was conducted.

  3. Performance Evaluation on Transmission Tower-Line System with Passive Friction Dampers Subjected to Wind Excitations

    Directory of Open Access Journals (Sweden)

    Bo Chen

    2015-01-01

    Full Text Available The vibration control and performance evaluation on a transmission-tower line system by using friction dampers subjected to wind excitations are carried out in this study. The three-dimensional finite element (FE model of a transmission tower is firstly constructed. A two-dimensional lumped mass model of a transmission tower is developed for dynamic analysis. The analytical model of transmission tower-line system is proposed by taking the dynamic interaction between the tower and the transmission lines into consideration. The mechanical model of passive friction damper is presented by involving the effects of damper axial stiffness. The equation of motion of the transmission tower-line system incorporated with the friction dampers disturbed by wind excitations is established. A real transmission tower-line system is taken as an example to examine the feasibility and reliability of the proposed control approach. An extensive parameter study is carried out to find the optimal parameters of friction damper and to assess the effects of slipping force axial stiffness and hysteresis loop on control performance. The work on an example structure indicates that the application of friction dampers with optimal parameters could significantly reduce wind-induced responses of the transmission tower-line system.

  4. Study of an YBCO HTS transmission cable system

    Energy Technology Data Exchange (ETDEWEB)

    Mukoyama, S. [Furukawa Electric Co., Ltd., Ecology and Energy Laboratory, 6, Yawata-Kaigandori, Ichihara, Chiba 290-8555 (Japan)], E-mail: mukoyama@ch.furukawa.co.jp; Yagi, M.; Hirano, N. [Furukawa Electric Co., Ltd., Ecology and Energy Laboratory, 6, Yawata-Kaigandori, Ichihara, Chiba 290-8555 (Japan); Amemiya, N. [Yokohama National University, Yokohama 240-8501 (Japan); Kashima, N.; Nagaya, S. [Chubu Electric Power Company, Nagoya 459-8522 (Japan); Izumi, T.; Shiohara, Y. [Superconductivity Research Laboratory, Tokyo 135-0062 (Japan)

    2007-10-01

    HTS transmission cables offer an innovative transmission line that differs from conventional technologies because HTS cables can send bulk power with extremely low loss. The HTS cable will contribute to energy saving and the prevention of global warming technologically. Reduction of cable loss is the most important development in economical cables for power networks. Today, second generation (2G) wires, such as an YBCO tape, are considered to have the potential to reduce AC loss. We developed YBCO power cables and succeeded in reducing AC loss to one-sixth the loss of BSCCO cable. According to our estimations, the total loss of an YBCO cable will be half the conventional (normal conducting) cable but yield the same power capacity.

  5. Linearization Technologies for Broadband Radio-Over-Fiber Transmission Systems

    OpenAIRE

    Xiupu Zhang; Ran Zhu; Dongyan Shen; Taijun Liu

    2014-01-01

    Linearization technologies that can be used for linearizing RoF transmission are reviewed. Three main linearization methods, i.e. electrical analog linearization, optical linearization, and electrical digital linearization are presented and compared. Analog linearization can be achieved using analog predistortion circuits, and can be used for suppression of odd order nonlinear distortion components, such as third and fifth order. Optical linearization includes mixed-polarization, dual-wavelen...

  6. HIV Transmission in a State Prison System, 1988–2005

    Science.gov (United States)

    Jafa, Krishna; McElroy, Peter; Fitzpatrick, Lisa; Borkowf, Craig B.; MacGowan, Robin; Margolis, Andrew; Robbins, Ken; Youngpairoj, Ae Saekhou; Stratford, Dale; Greenberg, Alan; Taussig, Jennifer; Shouse, R. Luke; LaMarre, Madeleine; McLellan-Lemal, Eleanor; Heneine, Walid; Sullivan, Patrick S.

    2009-01-01

    Introduction HIV prevalence among state prison inmates in the United States is more than five times higher than among nonincarcerated persons, but HIV transmission within U.S. prisons is sparsely documented. We investigated 88 HIV seroconversions reported from 1988–2005 among male Georgia prison inmates. Methods We analyzed medical and administrative data to describe seroconverters' HIV testing histories and performed a case-crossover analysis of their risks before and after HIV diagnosis. We sequenced the gag, env, and pol genes of seroconverters' HIV strains to identify genetically-related HIV transmission clusters and antiretroviral resistance. We combined risk, genetic, and administrative data to describe prison HIV transmission networks. Results Forty-one (47%) seroconverters were diagnosed with HIV from July 2003–June 2005 when voluntary annual testing was offered. Seroconverters were less likely to report sex (OR [odds ratio] = 0.02, 95% CI [confidence interval]: 0–0.10) and tattooing (OR = 0.03, 95% CI: prison after their HIV diagnosis than before. Of 67 seroconverters' specimens tested, 33 (49%) fell into one of 10 genetically-related clusters; of these, 25 (76%) reported sex in prison before their HIV diagnosis. The HIV strains of 8 (61%) of 13 antiretroviral-naïve and 21 (40%) of 52 antiretroviral-treated seroconverters were antiretroviral-resistant. Discussion Half of all HIV seroconversions were identified when routine voluntary testing was offered, and seroconverters reduced their risks following their diagnosis. Most genetically-related seroconverters reported sex in prison, suggesting HIV transmission through sexual networks. Resistance testing before initiating antiretroviral therapy is important for newly-diagnosed inmates. PMID:19412547

  7. HIV transmission in a state prison system, 1988-2005.

    Directory of Open Access Journals (Sweden)

    Krishna Jafa

    Full Text Available INTRODUCTION: HIV prevalence among state prison inmates in the United States is more than five times higher than among nonincarcerated persons, but HIV transmission within U.S. prisons is sparsely documented. We investigated 88 HIV seroconversions reported from 1988-2005 among male Georgia prison inmates. METHODS: We analyzed medical and administrative data to describe seroconverters' HIV testing histories and performed a case-crossover analysis of their risks before and after HIV diagnosis. We sequenced the gag, env, and pol genes of seroconverters' HIV strains to identify genetically-related HIV transmission clusters and antiretroviral resistance. We combined risk, genetic, and administrative data to describe prison HIV transmission networks. RESULTS: Forty-one (47% seroconverters were diagnosed with HIV from July 2003-June 2005 when voluntary annual testing was offered. Seroconverters were less likely to report sex (OR [odds ratio] = 0.02, 95% CI [confidence interval]: 0-0.10 and tattooing (OR = 0.03, 95% CI: <0.01-0.20 in prison after their HIV diagnosis than before. Of 67 seroconverters' specimens tested, 33 (49% fell into one of 10 genetically-related clusters; of these, 25 (76% reported sex in prison before their HIV diagnosis. The HIV strains of 8 (61% of 13 antiretroviral-naïve and 21 (40% of 52 antiretroviral-treated seroconverters were antiretroviral-resistant. DISCUSSION: Half of all HIV seroconversions were identified when routine voluntary testing was offered, and seroconverters reduced their risks following their diagnosis. Most genetically-related seroconverters reported sex in prison, suggesting HIV transmission through sexual networks. Resistance testing before initiating antiretroviral therapy is important for newly-diagnosed inmates.

  8. HIV transmission in a state prison system, 1988-2005.

    Science.gov (United States)

    Jafa, Krishna; McElroy, Peter; Fitzpatrick, Lisa; Borkowf, Craig B; Macgowan, Robin; Margolis, Andrew; Robbins, Ken; Youngpairoj, Ae Saekhou; Stratford, Dale; Greenberg, Alan; Taussig, Jennifer; Shouse, R Luke; Lamarre, Madeleine; McLellan-Lemal, Eleanor; Heneine, Walid; Sullivan, Patrick S

    2009-01-01

    HIV prevalence among state prison inmates in the United States is more than five times higher than among nonincarcerated persons, but HIV transmission within U.S. prisons is sparsely documented. We investigated 88 HIV seroconversions reported from 1988-2005 among male Georgia prison inmates. We analyzed medical and administrative data to describe seroconverters' HIV testing histories and performed a case-crossover analysis of their risks before and after HIV diagnosis. We sequenced the gag, env, and pol genes of seroconverters' HIV strains to identify genetically-related HIV transmission clusters and antiretroviral resistance. We combined risk, genetic, and administrative data to describe prison HIV transmission networks. Forty-one (47%) seroconverters were diagnosed with HIV from July 2003-June 2005 when voluntary annual testing was offered. Seroconverters were less likely to report sex (OR [odds ratio] = 0.02, 95% CI [confidence interval]: 0-0.10) and tattooing (OR = 0.03, 95% CI: prison after their HIV diagnosis than before. Of 67 seroconverters' specimens tested, 33 (49%) fell into one of 10 genetically-related clusters; of these, 25 (76%) reported sex in prison before their HIV diagnosis. The HIV strains of 8 (61%) of 13 antiretroviral-naïve and 21 (40%) of 52 antiretroviral-treated seroconverters were antiretroviral-resistant. Half of all HIV seroconversions were identified when routine voluntary testing was offered, and seroconverters reduced their risks following their diagnosis. Most genetically-related seroconverters reported sex in prison, suggesting HIV transmission through sexual networks. Resistance testing before initiating antiretroviral therapy is important for newly-diagnosed inmates.

  9. Siemens repairs and overhauls HVDC transformers on site; Reparatur und Ueberholung von HGUe-Transformatoren vor Ort. Service unter erschwerten Bedingungen

    Energy Technology Data Exchange (ETDEWEB)

    Maendl, G. [Siemens Unternehmensbereichs Power Transmission und Distribution (PTD), Nuernberg (Germany)

    2003-02-24

    Since two strongly overloaded 180 tonne transformers cannot be transported back to the Nuremberg factory, Siemens Power Transmission and Distribution (PTD) is repairing and overhauling them at their place of use, the Cahora-Bassa dam in Mozambique. The absence of a bridge (destroyed in the civil war) across the Zambezi river makes it impossible to move them by road. The two power transformers were installed in the 1970s during construction of the high-voltage direct-current (HVDC) transmission link, along which power from the hydrogeneration plant in Mozambique is conveyed 1 450 kilometers to Johannesburg in South Africa. (orig.) [German] Weil zwei stark ueberbeanspruchte 180-t-Transformatoren nicht ins Nuernberger Transformatorenwerk zuruecktransportiert werden koennen, repariert und ueberholt Siemens Power Transmission and Distribution (PTD) die Transformatoren direkt an ihrem Einsatzort am Cahora-Bassa-Staudamm in Mosambik. Eine in den Buergerkriegswirren zerstoerte Bruecke ueber den Sambesi-Fluss vereitelt den Transport der Schwergewichte auf dem Landweg. Die beiden Leistungstransformatoren gehoeren zu der in den siebziger Jahren gebauten Hochspannungs-Gleichstrom-Uebertragungsstrecke (HGUe), ueber die der Strom des Wasserkraftwerks in Mosambik 1 450 km weit nach Johannesburg in Suedafrika transportiert wird. (orig.)

  10. Research on Image Transmission System Based on 3G Communication Platform

    Directory of Open Access Journals (Sweden)

    Jingfeng Zang

    2014-07-01

    Full Text Available A wireless image real-time transmission system is designed by using 3G wireless communication platform and ARM + DSP embedded system. In the environment of 3G networks, the embedded equipment has realized the functions of coding, acquisition, network transmission, decoding and playing. It is realized for real-time video of intelligent control and video compression, storage and playback in the 3G embedded image transmission system. It is especially suitable for remote location or irregular cable network transmission conditions applications. It is shown that in the 3G network video files are transferred quickly. The real-time transmission of H.264 video is broadcasted smoothly, and color distortion is less. The server can control client by remote intelligent units.

  11. Linearization Technologies for Broadband Radio-Over-Fiber Transmission Systems

    Directory of Open Access Journals (Sweden)

    Xiupu Zhang

    2014-11-01

    Full Text Available Linearization technologies that can be used for linearizing RoF transmission are reviewed. Three main linearization methods, i.e. electrical analog linearization, optical linearization, and electrical digital linearization are presented and compared. Analog linearization can be achieved using analog predistortion circuits, and can be used for suppression of odd order nonlinear distortion components, such as third and fifth order. Optical linearization includes mixed-polarization, dual-wavelength, optical channelization and the others, implemented in optical domain, to suppress both even and odd order nonlinear distortion components, such as second and third order. Digital predistortion has been a widely used linearization method for RF power amplifiers. However, digital linearization that requires analog to digital converter is severely limited to hundreds of MHz bandwidth. Instead, analog and optical linearization provide broadband linearization with up to tens of GHz. Therefore, for broadband radio over fiber transmission that can be used for future broadband cloud radio access networks, analog and optical linearization are more appropriate than digital linearization. Generally speaking, both analog and optical linearization are able to improve spur-free dynamic range greater than 10 dB over tens of GHz. In order for current digital linearization to be used for broadband radio over fiber transmission, the reduced linearization complexity and increased linearization bandwidth are required. Moreover, some digital linearization methods in which the complexity can be reduced, such as Hammerstein type, may be more promising and require further investigation.

  12. Avoidance of Pressure Oscillations in Discrete Fluid Power Systems with Transmission Lines - An Analytical Approach

    DEFF Research Database (Denmark)

    Hansen, Anders Hedegaard; Pedersen, Henrik C.

    2014-01-01

    transmission lines often impose pressure oscillation/ pressure waves to occur in systems operated discrete or very fast. The current work focus on developing an analytical algorithm computing the flow requirement into a cylinder chamber through a transmission line that will impose a smooth pressure change...

  13. Study on frequency characteristics of wireless power transmission system based on magnetic coupling resonance

    Science.gov (United States)

    Liang, L. H.; Liu, Z. Z.; Hou, Y. J.; Zeng, H.; Yue, Z. K.; Cui, S.

    2017-11-01

    In order to study the frequency characteristics of the wireless energy transmission system based on the magnetic coupling resonance, a circuit model based on the magnetic coupling resonant wireless energy transmission system is established. The influence of the load on the frequency characteristics of the wireless power transmission system is analysed. The circuit coupling theory is used to derive the minimum load required to suppress frequency splitting. Simulation and experimental results verify that when the load size is lower than a certain value, the system will appear frequency splitting, increasing the load size can effectively suppress the frequency splitting phenomenon. The power regulation scheme of the wireless charging system based on magnetic coupling resonance is given. This study provides a theoretical basis for load selection and power regulation of wireless power transmission systems.

  14. Localização de faltas em linhas de transmissão em corrente contínua segmentadas

    Directory of Open Access Journals (Sweden)

    Eduardo Gonzaga Silveira

    2013-11-01

    Full Text Available Este trabalho apresenta uma técnica para a localização de faltas em sistemas de transmissão High Voltage Direct Current (HVDC constituídos por linhas aéreas e cabos isolados. O método foi baseado na coleta de dados de dois terminais nas extremidades do elo de corrente contínua e pela detecção de faltas através de coeficientes da Transformada Wavelet Discreta tipo Haar. A partir do problema proposto, foi simulado com o auxílio do Alternative Transient Program (ATP, um sistema de transmissão em corrente contínua monopolar com conversores a tiristor Current Source Converter (CSC, constituído de duas linhas aéreas de 150 km e 80 km, e um segmento intermediário de cabo subterrâneo com 80 km. Os dados das respostas transitórias de curtos-circuitos em diferentes segmentos do elo foram carregados em uma interface gráfica criada no Matrix Laboratory (MATLAB, para realizar as rotinas de pré-processamento, além de detectar e localizar a falta. O método foi testado para diferentes taxas de amostragem e impedâncias de falta, ele apresentou resultados satisfatórios na localização de faltas em todos os segmentos da linha, com erros em torno de 0,5% do comprimento total do elo, além do baixo custo computacional, o que mostra a viabilidade de sua implementação prática.Palavras-chave: HVDC. Localização de faltas. ATP. Transformada Wavelet.Location of faults in transmission lines in continuous segmented streamAbstractThis paper presents a technique for location of faults in High Voltage Direct Current (HVDC transmission systems constituted of overhead lines and cables. The method was based on data collection of two terminals on the extremity of the continuous stream link, and through the fault detection using the Discrete Wavelet Transform coefficients of Haar type. From the proposed problem, it was simulated, with the support of the Alternative Transient Program (ATP, a transmission system in monopolar continuous stream with

  15. Design of wireless video transmission system based on STM32 microcontroller

    Science.gov (United States)

    Yang, Fan; Ma, Chunting; Li, Haoyi

    2017-03-01

    The design of a wireless video transmission system based on STM32, the system uses the STM32F103VET6 microprocessor as the core, through the video acquisition module collects video data, video data will be sent to the receiver through the wireless transmitting module, receiving data will be displayed on the LCD screen. The software design process of receiver and transmitter is introduced. The experiment proves that the system realizes wireless video transmission function.

  16. Noise and signal interference in optical fiber transmission systems an optimum design approach

    CERN Document Server

    Bottacchi, Stefano

    2008-01-01

    A comprehensive reference to noise and signal interference in optical fiber communications Noise and Signal Interference in Optical Fiber Transmission Systems is a compendium on specific topics within optical fiber transmission and the optimization process of the system design. It offers comprehensive treatment of noise and intersymbol interference (ISI) components affecting optical fiber communications systems, containing coverage on noise from the light source, the fiber and the receiver. The ISI is modeled with a statistical approach, leading to new useful computational m

  17. Transmission Congestion Management using a Wind Integrated Compressed Air Energy Storage System

    OpenAIRE

    S. Gope; Goswami, A. K.; P.K. Tiwari

    2017-01-01

    Transmission congestion is a vital problem in the power system security and reliability sector. To ensure the stable operation of the system, a congestion free power network is desirable. In this paper, a new Congestion Management (CM) technique, the Wind integrated Compressed Air Energy Storage (WCAES) system is used to alleviate transmission congestion and to minimize congestion mitigation cost. The CM problem has been solved by using the Generator Sensitivity Factor (GSF) and the Bus Sensi...

  18. [Developing a high quality video transmission system based on mobile network].

    Science.gov (United States)

    Wen, Ming; Hu, Haibo

    2014-01-01

    To meet the demands of high definition of video and transmission at real-time during the surgery of endoscope, this paper designs an HD mobile video transmission system. This system uses H.264/AVC to encode the original video data and transports it in the network by RTP/RTCP protocol. Meanwhile, the system implements a stable video transmission in portable terminals (such as tablet PCs, mobile phones) under the 3G mobile network. The test result verifies the strong repair ability and stability under the conditions of low bandwidth, high packet loss rate, and high delay and shows a high practical value.

  19. Photonic Crystal Fibres as the Transmission Medium for Future Optical Communication Systems

    DEFF Research Database (Denmark)

    Zsigri, Beata

    2006-01-01

    and index guiding PCFs. Nevertheless, both PCF types exhibit numerous novel properties { not obtainable by standard fibre technology { that are very attractive for optical communication systems. Even though PCFs have now existed already for a decade, their exploitation for telecommunication applications has...... transmission experiments comprising PCFs are presented. Among others, the first reported 10 Gbit/s transmission over 5.6 km PCF is described. The total transmission distance over index guiding PCF is increased to 57.6 km, more than four times longer than the achievable lengths of the date. The total capacity...... of index guiding PCFs as transmission media, as nonlinear media for signal processing or as dispersion compensating fibre for future high capacity long-haul transmission systems is demonstrated. Finally, the telecommunication applications of photonic bandgap fibres are investigated. This work focusses...

  20. STUDY OF DATA TRANSMISSION SYSTEMS FOR A SPACE SIMULATION CHAMBER-DESIGN AND TEST OF AN ENGINEERING MODEL,

    Science.gov (United States)

    SPACE ENVIRONMENTS, TEST FACILITIES, DATA TRANSMISSION SYSTEMS , SIMULATION, RADAR TRANSMITTERS, PULSES, AMPLITUDE MODULATION, MICROWAVES, SPACECRAFT, GIMBALS, MULTIPLEXING, ENGINEERING DRAWINGS, CIRCUITS.

  1. CAMEX-4 DC-8 INFORMATION COLLECTION AND TRANSMISSION SYSTEM V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The Camex-4 DC-8 Information Collection and Transmission System (ICATS) is designed to: 1) interface and process avionics and environmental paramaters from the...

  2. The effect analysis of strain rate on power transmission tower-line system under seismic excitation.

    Science.gov (United States)

    Tian, Li; Wang, Wenming; Qian, Hui

    2014-01-01

    The effect analysis of strain rate on power transmission tower-line system under seismic excitation is studied in this paper. A three-dimensional finite element model of a transmission tower-line system is created based on a real project. Using theoretical analysis and numerical simulation, incremental dynamic analysis of the power transmission tower-line system is conducted to investigate the effect of strain rate on the nonlinear responses of the transmission tower and line. The results show that the effect of strain rate on the transmission tower generally decreases the maximum top displacements, but it would increase the maximum base shear forces, and thus it is necessary to consider the effect of strain rate on the seismic analysis of the transmission tower. The effect of strain rate could be ignored for the seismic analysis of the conductors and ground lines, but the responses of the ground lines considering strain rate effect are larger than those of the conductors. The results could provide a reference for the seismic design of the transmission tower-line system.

  3. System Design for Ocean Sensor Data Transmission Based on Inductive Coupling

    Science.gov (United States)

    Xu, Ming; Liu, Fei; Zong, Yuan; Hong, Feng

    Ocean observation is the precondition to explore and utilize ocean. How to acquire ocean data in a precise, efficient and real-time way is the key question of ocean surveillance. Traditionally, there are three types of methods for ocean data transmission: underwater acoustic, GPRS via mobile network and satellite communication. However, none of them can meet the requirements of efficiency, accuracy, real-time and low cost at the same time. In this paper, we propose a new wireless transmission system for underwater sensors, which established on FGR wireless modules, combined with inductive coupling lab and offshore experiments confirmed the feasibility and effectiveness of the proposed wireless transmission system.

  4. Training-based Channel Estimation for Signal Equalization and OPM in 16-QAM Optical Transmission Systems

    DEFF Research Database (Denmark)

    Pittalà, Fabio; Hauske, Fabian N.; Ye, Yabin

    2012-01-01

    Efficient channel estimation for signal equalization and OPM based on short CAZAC sequences with QPSK and 8PSK constellation formats is demonstrated in a 224-Gb/s PDM 16-QAM optical linear transmission system.......Efficient channel estimation for signal equalization and OPM based on short CAZAC sequences with QPSK and 8PSK constellation formats is demonstrated in a 224-Gb/s PDM 16-QAM optical linear transmission system....

  5. Simulation on Dual-stream Transmission System of Unmanned Tracked Armored Vehicle Using ADAMS

    Directory of Open Access Journals (Sweden)

    Sun Wei

    2015-01-01

    Full Text Available For the dual-stream transmission system of unmanned tracked armored vehicle, simulation analysis is carried out. Using SolidWorks to establish three-dimensional model of its chassis, the result of the simulation is processed in AdAMS/Solver. The simulation results are showed in lines. Comparative analysis for each simulation lines is conducted, and it verifies the feasibility of the dual-stream transmission system.

  6. A Case Study Of Turkish Transmission System For VoltageDips

    OpenAIRE

    Inan, E.; Alboyaci, B.; Bak, Claus Leth

    2009-01-01

    Power quality problems usually appear in the form of voltage sags, transients and harmonics. From these three broad categories of power quality problems, voltage dips account the most disturbances experienced by industrial customers. Voltage dips generally refer to instantaneous short-duration voltage variations. The aim of this paper is to have an idea about voltage dip performance of Turkey Transmission System. Turkey's transmission system has 21 regions. For simulations, 2nd region, which ...

  7. Recent and future situation of Japan’s T&D system

    Directory of Open Access Journals (Sweden)

    Kyoichi Uehara

    2016-01-01

    Full Text Available Japan suffered from the Great East Japan Earthquake followed by the nuclear disaster. As a result, we experienced rolling outages for a few months in the Tokyo and Tohoku area. Japan’s power transmission system consists of 50 Hz AC and 60 Hz AC in eastern and western Japan respectively. When the nuclear disaster occurred in Fukushima, enough electricity hasn’t been supplied in eastern area. Power interchange capacity between east and west was small because of small redundant T&D system design. Based on this rolling outage and some present electricity supplying issues in Japan, METI (Ministry of Economy, Trade and Industry has set the electricity system reform committee to improve this situation and make a good T&D system for the future. This committee reported the discussed issue to the Japanese METI and METI proposed policy on Electricity System Reform to the Japanese Cabinet. As a result, the Japanese Electricity System Reform policy was adopted. This future T&D system deals with redundant T&D systems between east and west, how to handle large amounts of renewable electrical energy, and how to fully de-regulate the distribution market. HVDC (VSC system will be introduced between Hokkaido and Honshu as a subsea cable transmission system and HVDC transmission system between eastern area and western area. This paper describes recent and future Japan’s T&D systems. This will be helpful to understand how to solve the issues of Japan’s T&D system.

  8. Experiments on Long-Haul High-Capacity Transmission Systems

    Science.gov (United States)

    Bosco, Gabriella; Matera, Francesco; Ennser, Karin; Ibsen, Morten; Marazzi, Lucia; Parmigiani, Francesca; Petropoulos, Periklis; Poggiolini, Pierluigi; Tabacchiera, Marco; Zannin, Marcelo

    Progress in optical communications has been one of the key factors for the enormous growth of the ICT sector, and, in particular, of the Internet phenomenon. Such a progress has been driven by experimental successes that have been obtained in the last three decades in several laboratories all over the world, and we have witnessed a fantastic challenge among such labs to reach record targets such as maximum bit rate, maximum propagation distance, higher performance, maximum efficiency, and, recently, minimum energy consumption. The search for the maximum bit rate × distance was based on the principle of infinite bandwidth of the optical fiber that let us to imagine transmission of enormous capacities over transoceanic distances, especially after the invention of the optical amplifier.

  9. Massive WDM and TDM Soliton Transmission Systems : a ROSC Symposium

    CERN Document Server

    2002-01-01

    This book summarizes the proceedings of the invited talks presented at the “International Symposium on Massive TDM and WDM Optical Soliton Tra- mission Systems” held in Kyoto during November 9–12, 1999. The symposium is the third of the series organized by Research Group for Optical Soliton C- munications (ROSC) chaired by Akira Hasegawa. The research group, ROSC, was established in Japan in April 1995 with a support of the Japanese Ministry of Post and Telecommunications to promote collaboration and information - change among communication service companies, communication industries and academic circles in the theory and application of optical solitons. The symposium attracted enthusiastic response from worldwide researchers in the field of soliton based communications and intensive discussions were made. In the symposium held in 1997, new concept of soliton transmission based on dispersion management of optical fibers were presented. This new soliton is now called the dispersion managed soliton. The p...

  10. Electrical Power Supply to Offshore Oil Installations by High Voltage Direct Current Transmission

    Energy Technology Data Exchange (ETDEWEB)

    Myhre, Joergen Chr.

    2001-07-01

    This study was initiated to investigate if it could be feasible to supply offshore oil installations in the North Sea with electrical power from land. A prestudy of alternative converter topologies indicated that the most promising solution would be to investigate a conventional system with reduced synchronous compensator rating. The study starts with a summary of the state of power supply to offshore installations today, and a short review of classical HVDC transmission. It goes on to analyse how a passive network without sources influences the inverter. The transmission, with its current controlled rectifier and large inductance, is simulated as a current source. Under these circumstances the analysis shows that the network frequency has to adapt in order to keep the active and reactive power balance until the controllers are able to react. The concept of firing angle for a thyristor is limited in a system with variable frequency, the actual control parameter is the firing delay time. Sensitivity analysis showed some astonishing consequences. The frequency rises both by an increase in the active and in the reactive load. The voltage falls by an increase in the active load, but rises by an increase in the inductive load. Two different control principles for the system of inverter, synchronous compensator and load are defined. The first takes the reference for the firing delay time from the fundamental voltage at the point of common coupling. The second takes the reference for the firing delay time from the simulated EMF of the synchronous compensator. Of these, the second is the more stable and should be chosen as the basis for a possible control system. Two simulation tools are applied. The first is a quasi-phasor model running on Matlab with Simulink. The other is a time domain model in KREAN. The time domain model is primarily used for the verification of the quasi-phasor model, and shows that quasi-phasors is still a valuable tool for making a quick analysis

  11. Improvement of wireless transmission system performance for EEG signals based on development of scalar quantization

    Directory of Open Access Journals (Sweden)

    Mohsen Habibnezhad

    2013-12-01

    Full Text Available Advancement of wireless technology leads to some developments in current wireless electroencephalography. Through improving the transmission method of brainwaves, it would be possible to bring more convenience for the patients in need and give this opportunity to others for discovering other aspects of the amazing brainwave. What has been proposed in this study is a new type of adjustable backward quantization method which exploits the nature of the brainwave signal. This method is based on the nature of the captured brainwave and its quantization boundary changes based on the amplitude of each EEG captured signal. The proposed quantization scheme has been analyzed with uniform and Gaussian distribution of quantization level. Consequently, the Backward Gaussian Quantization with Adjustable Boundary and two Word Memories beside the Backward Uniform Quantization with Adjustable Boundary and two Word Memories are introduced by this experiment. In addition, the performance of wireless transmission system and the proposed quantizer’s efficiency for very low frequency (up to 100 Hz and amplitude EEG signal have been noticed. With doing so, we simulated the transmitter and receiver by MATLAB® software. To model the medium, channel was assumed as Additive White Gaussian Noise (AWGN. Meanwhile analysis is done for the whole wireless system performance in terms of transmission range, compared with current available wireless transmission systems on the market. It should be noticed that the transmission range of the proposed wireless transmission system is compared to the transmission range of current wireless EEG systems when there is no obstacle between transmitter and receiver. Furthermore, some relevant parameters to evaluate the quality of the proposed quantization method were examined. To sum up, the proposed quantization schemes show considerable performance in terms of Quantization Rate for constant MSQE and SQNR in comparison with Uniform

  12. Long-Haul Dense Space Division Multiplexed Transmission over Low-Crosstalk Heterogeneous 32-Core Transmission Line Using Partial Recirculating Loop System

    DEFF Research Database (Denmark)

    Mizuno, Takayuki; Shibahara, Kohki; Ye, Feihong

    2017-01-01

    In this paper, we present long-haul 32-core dense space division multiplexed (DSDM) unidirectional transmission over a single-mode multicore transmission line. We developed a low-crosstalk heterogeneous 32-core fiber with a square lattice arrangement, and a novel partial recirculating loop system....... The span crosstalk of the 51.4-km 32-core transmission line was less than −34.5 dB. This allowed the transmission of polarization division multiplexed 16 quadrature amplitude modulation (PDM-16QAM) signals through all 32-cores over a long distance exceeding a thousand km. We demonstrate 32-core DSDM 20...... wavelength division multiplexed (WDM) PDM-16QAM transmission over 1644.8 km with a high aggregate spectral efficiency of 201.46 b/s/Hz. Additionally, we examine the effect of crosstalk on the transmission performance of each core, and show that the Q-penalty has strong correlation with inter-core crosstalk....

  13. Fundamental Study of Smart IC Card System Using Ultrasonic Information Transmission

    Science.gov (United States)

    Suzuki, Shin‑nosuke; Ishihara, Manabu; Katane, Tamotsu; Saito, Osami; Kobayashi, Kazuto

    2006-05-01

    In this study, we propose a new type of smart IC card using ultrasonic information transmission. Ultrasonic transmission is safe for the human body and does not cause malfunctioning of electronic equipments. In addition, information transmission using ultrasonic can prevent “skimming” to utilize ultrasonic characteristics that have a large attenuation in air and a sharp directivity. Our study deals with an experimental model system for preliminary development and the analysis of its results. To minimize the power consumption of the card, the system does not need carrier waves to transmit information from the card to the card-reader/writer (R/W), because base band signal is transmitted directly. For the results of the prototype experiment, a transmission speed of 115.2 kbps is obtained at less than 1 mm distance. The proposed ultrasonic IC card system can have various practical applications in which secret information is absolutely kept.

  14. Dynamic Reactive Power Control in Offshore HVDC Connected Wind Power Plants

    DEFF Research Database (Denmark)

    Sakamuri, Jayachandra N.; Cutululis, Nicolaos Antonio; Rather, Zakir Hussain

    2016-01-01

    This paper presents a coordinated reactive power control for a HVDC connected cluster of offshore wind power plants (WPPs). The reactive power reference for the WPP cluster is estimated by an optimization algorithm aiming at minimum active power losses in the offshore AC Grid. For each optimal......, such as wind turbine (WT) terminal, collector cable, and export cable, on the dynamic voltage profile of the offshore grid is investigated. Furthermore, the dynamic reactive power contribution from WTs from different WPPs of the cluster for such faults has also been studied....

  15. Investigations and system design for simultaneous energy and data transmission through inductively coupled resonances

    Science.gov (United States)

    Schmidt, C.; Lloret Fuentes, E.; Buchholz, M.

    2015-11-01

    Wireless Power Transfer (WPT) with simultaneous data transmission through coupled magnetic resonators is investigated in this paper. The development of this system is dedicated to serve as a basis for applications in the field of Ambient Assisted Living (AAL), for example tracking vital parameters remotely, charge and control sensors and so on. Due to these different scenarios we consider, it is important to have a system which is reliable under the circumstance of changing positioning of the receiving device. State of the art radio systems would be able to handle this. Nevertheless, energy harvesting from far field sources is not sufficient to power the devices additionally on mid-range distances. For this reason, coupled magnetic resonant circuits are proposed as a promising alternative, although suffering from more complex positioning dependency. Based on measurements on a simple prototype system, an equivalent circuit description is used to model the transmission system dependent on different transmission distances and impedance matching conditions. Additionally, the simulation model is used to extract system parameters such as coupling coefficients, coil resistance and self-capacitance, which cannot be calculated in a simple and reliable way. Furthermore, a mathematical channel model based on the schematic model has been built in MATLAB©. It is used to point out the problems occurring in a transmission system with variable transmission distance, especially the change of the passband's centre frequency and its bandwidth. Existing solutions dealing with this distance dependent behaviour, namely the change of the transmission frequency dependent on distance and the addition of losses to the resonators to increase the bandwidth, are considered as not inventive. First, changing the transmission frequency increases the complexity in the data transmission system and would use a disproportional total bandwidth compared to the actually available bandwidth

  16. Optimisation of Transmission Systems by use of Phase Shifting Transformers

    Energy Technology Data Exchange (ETDEWEB)

    Verboomen, J.

    2008-10-13

    In this thesis, transmission grids with PSTs (Phase Shifting Transformers) are investigated. In particular, the following goals are put forward: (a) The analysis and quantification of the impact of a PST on a meshed grid. This includes the development of models for the device; (b) The development of methods to obtain optimal coordination of several PSTs in a meshed grid. An objective function should be formulated, and an optimisation method must be adopted to solve the problem; and (c) The investigation of different strategies to use a PST. Chapter 2 gives a short overview of active power flow controlling devices. In chapter 3, a first step towards optimal PST coordination is taken. In chapter 4, metaheuristic optimisation methods are discussed. Chapter 5 introduces DC load flow approximations, leading to analytically closed equations that describe the relation between PST settings and active power flows. In chapter 6, some applications of the methods that are developed in earlier chapters are presented. Chapter 7 contains the conclusions of this thesis, as well as recommendations for future work.

  17. Mid-Atlantic Offshore Wind Interconnection and Transmission (MAOWIT)

    Energy Technology Data Exchange (ETDEWEB)

    Kempton, Willett [Univ. of Delaware, Newark, DE (United States)

    2016-04-05

    This project has carried out a detailed analysis to evaluate the pros and cons of offshore transmission, a possible method to decrease balance-of-system costs and permitting time identified in the DOE Office Wind Strategic Plan (DOE, 2011). It also addresses questions regarding the adequacy of existing transmission infrastructure and the ability of existing generating resources to provide the necessary Ancillary Services (A/S) support (spinning and contingency reserves) in the ISO territory. This project has completed the tasks identified in the proposal: 1. Evaluation of the offshore wind resource off PJM, then examination of offshore wind penetrations consistent with U.S. Department of Energy’s (DOE) targets and with their assumed resource size (DOE, 2011). 2. Comparison of piecemeal radial connections to the Independent System Operator (ISO) with connections via a high-voltage direct current (HVDC) offshore network similar to a team partner. 3. High-resolution examination of power fluctuations at each node due to wind energy variability 4. Analysis of wind power production profiles over the Eastern offshore region of the regional ISO to assess the effectiveness of long-distance, North- South transmission for leveling offshore wind energy output 5. Analysis of how the third and fourth items affect the need for ISO grid upgrades, congestion management, and demand for Ancillary Services (A/S) 6. Analysis of actual historic 36-hr and 24-hr forecasts to solve the unit commitment problem and determine the optimal mix of generators given the need to respond to both wind variability and wind forecasting uncertainties.

  18. On the Performance Evaluation of a MIMO-WCDMA Transmission Architecture for Building Management Systems.

    Science.gov (United States)

    Tsampasis, Eleftherios; Gkonis, Panagiotis K; Trakadas, Panagiotis; Zahariadis, Theodοre

    2018-01-08

    The goal of this study was to investigate the performance of a realistic wireless sensor nodes deployment in order to support modern building management systems (BMSs). A three-floor building orientation is taken into account, where each node is equipped with a multi-antenna system while a central base station (BS) collects and processes all received information. The BS is also equipped with multiple antennas; hence, a multiple input-multiple output (MIMO) system is formulated. Due to the multiple reflections during transmission in the inner of the building, a wideband code division multiple access (WCDMA) physical layer protocol has been considered, which has already been adopted for third-generation (3G) mobile networks. Results are presented for various MIMO orientations, where the mean transmission power per node is considered as an output metric for a specific signal-to-noise ratio (SNR) requirement and number of resolvable multipath components. In the first set of presented results, the effects of multiple access interference on overall transmission power are highlighted. As the number of mobile nodes per floor or the requested transmission rate increases, MIMO systems of a higher order should be deployed in order to maintain transmission power at adequate levels. In the second set of results, a comparison is performed among transmission in diversity combining and spatial multiplexing mode, which clearly indicate that the first case is the most appropriate solution for indoor communications.

  19. An applicable 5.8 GHz wireless power transmission system with rough beamforming to Project Loon

    Directory of Open Access Journals (Sweden)

    Chang-Jun Ahn

    2016-06-01

    Full Text Available In recent, Google proposed the Project Loon being developed with the mission of providing internet access to rural and remote areas using high-altitude balloons. In this paper, we describe an applicable prototype of 5.8 GHz wireless power transmission system with rough beamforming method to Project Loon. From the measurement results, transmit beamforming phased array antenna can transmit power more efficiently compared to a horn antenna and array antenna without beamforming with increasing the transmission distance. For the transmission distance of 1000 mm, transmit beamforming phased array antenna can obtain higher received power about 1.46 times compared to array antenna without transmit beamforming.

  20. Coordinated Transmissions to Direct and Relayed Users in Wireless Cellular Systems

    DEFF Research Database (Denmark)

    Thai, Chan; Popovski, Petar; Kaneko, Megumi

    2011-01-01

    the interference. In this paper we use these principles to devise new transmission schemes in wireless cellular systems that feature both users served directly by the base stations (direct users) and users served through relays (relayed users). We present four different schemes for coordinated transmission...... of uplink and downlink traffic in which one direct and one relayed user are served. These schemes are then used as building blocks in multi–user scenarios, where we present several schemes for scheduling pairs of users for coordinated transmissions. The optimal scheme involves exhaustive search of the best......The ideas of wireless network coding at the physical layer promise high throughput gains in wireless systems with relays and multi–way traffic flows. This gain can be ascribed to two principles: (1) joint transmission of multiple communication flows and (2) usage of a priori information to cancel...

  1. The design and analysis of channel transmission communication system of XCTD profiler.

    Science.gov (United States)

    Zheng, Yu; Wang, Xiao-Rui; Jin, Xiang-Yu; Song, Guo-Min; Shang, Ying-Sheng; Li, Hong-Zhi

    2016-10-01

    In this paper, a channel transmission communication system of expendable conductivity-temperature-depth is established in accordance to the operation characteristics of the transmission line to more accurately assess the characteristics of deep-sea abandoned profiler channel. The wrapping inductance is eliminated to maximum extent through the wrapping pattern of the underwater spool and the overwater spool and the calculation of the wrapping diameter. The feasibility of the proposed channel transmission communication system is verified through theoretical analysis and practical measurement of the transmission signal error rate in the amplitude shift keying (ASK) modulation. The proposed design provides a new research method for the channel assessment of complex abandoned measuring instrument and an important experiment evidence for the rapid development of the deep-sea abandoned measuring instrument.

  2. A Paging Indicator Transmission Technique for Mobile WiMAX Systems

    Science.gov (United States)

    Kim, Yeong-Jun; Yoo, Hyun-Il; Woo, Kyung-Soo; Lee, Jung-Ryun; Lee, Heesoo; Cho, Yong-Soo

    In a cellular system, efficient power saving techniques for a mobile station (MS) are necessary because of its inherently limited battery capacity. The paging indicator (PI) transmission scheme in CDMA cellular systems is known to be an effective power saving strategy. However, in OFDM-based cellular systems, the MS has to operate FFT for PI symbol detection, resulting in a significant power consumption. In this letter, a PI transmission technique with reduced power consumption using the preamble in OFDM-based cellular systems, especially for mobile WiMAX systems, is proposed for the MS under power saving mode. Simulations indicate a 30-50% power saving from our proposed PI transmission technique, at the expense of a slight increase in paging response delay.

  3. Guidelines for transient analysis in water transmission and distribution systems

    NARCIS (Netherlands)

    Pothof, I.W.M.; Karney, B.W.

    2012-01-01

    All water systems leak, and many supply systems do so considerably, with water losses typically of approximately 20% of the water production. The IWA Water Loss Task Force aims for a significant reduction of annual water losses by drafting documents to assist practitioners and others to prevent,

  4. Analysis of Basic Transmission Networks for Integrated Ship Control Systems

    DEFF Research Database (Denmark)

    Hansen, T.N.; Granum-Jensen, M.

    1993-01-01

    Description of a computer network for Integrated Ship Control Systems which is going to be developed as part of an EC-project. Today equipment of different make are not able to communicate with each other because most often each supplier of ISC systems has got their own proprietary network.....

  5. Kansas Communication and Instruction System through Fiber-Optic Transmission.

    Science.gov (United States)

    Kansas State Dept. of Education, Topeka.

    Schools and communities will restructure as they move into the next decade. The success of this restructuring will be dependent upon access to and sharing of quality teaching and information through an expanded communication system. One of the major two-way interactive technologies is the fiber-optic cable: a delivery system that will provide…

  6. High speed data transmission coaxial-cable in the space communication system

    Science.gov (United States)

    Su, Haohang; Huang, Jing

    2018-01-01

    An effective method is proved based on the scattering parameter of high speed 8-core coaxial-cable measured by vector network analyzer, and the semi-physical simulation is made to receive the eye diagram at different data transmission rate. The result can be apply to analysis decay and distortion of the signal through the coaxial-cable at high frequency, and can extensively design for electromagnetic compatibility of high-speed data transmission system.

  7. State of the art analysis of online fault location on AC cables in underground transmission systems

    DEFF Research Database (Denmark)

    Jensen, Christian Flytkjær; Gudmundsdottir, Unnur Stella; Bak, Claus Leth

    2011-01-01

    In this article the state of the art research for online fault location on cross-bonded transmission level cables is presented. The article is focused on the difficulties in using the algorithms developed for OHL-systems and distribution cables directly on cross-bonded transmission cables....... Impedance based methods, methods based on solving the line differential equations, methods based on traveling wave methods and methods based on artificial intelligence networks are presented and discussed....

  8. Open-source framework for power system transmission and distribution dynamics co-simulation

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Renke; Fan, Rui; Daily, Jeff; Fisher, Andrew; Fuller, Jason

    2017-06-27

    The promise of the smart grid entails more interactions between the transmission and distribution networks, and there is an immediate need for tools to provide the comprehensive modelling and simulation required to integrate operations at both transmission and distribution levels. Existing electromagnetic transient simulators can perform simulations with integration of transmission and distribution systems, but the computational burden is high for large-scale system analysis. For transient stability analysis, currently there are only separate tools for simulating transient dynamics of the transmission and distribution systems. In this paper, we introduce an open source co-simulation framework “Framework for Network Co-Simulation” (FNCS), together with the decoupled simulation approach that links existing transmission and distribution dynamic simulators through FNCS. FNCS is a middleware interface and framework that manages the interaction and synchronization of the transmission and distribution simulators. Preliminary testing results show the validity and capability of the proposed open-source co-simulation framework and the decoupled co-simulation methodology.

  9. Game Changing Usage of High-Voltage Power Transmission Systems as Extremely Large Antennas for Space Physical and Geophysical Remote Imaging Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Geomagnetic storms drive geomagnetically induced currents (GIC) in high-voltage power transmission systems worldwide. GIC distribution in the transmission system is...

  10. Impact of Utility-Scale Distributed Wind on Transmission-Level System Operations

    Energy Technology Data Exchange (ETDEWEB)

    Brancucci Martinez-Anido, C.; Hodge, B. M.

    2014-09-01

    This report presents a new renewable integration study that aims to assess the potential for adding distributed wind to the current power system with minimal or no upgrades to the distribution or transmission electricity systems. It investigates the impacts of integrating large amounts of utility-scale distributed wind power on bulk system operations by performing a case study on the power system of the Independent System Operator-New England (ISO-NE).

  11. Development and Application of Wireless Power Transmission Systems for Wireless ECG Sensors

    Directory of Open Access Journals (Sweden)

    Jin-Chul Heo

    2018-01-01

    Full Text Available We investigated the variations in the magnetic field distribution and power transmission efficiency, resulting from changes in the relative positions of the transmitting and receiving coils, for electromagnetic induction-type wireless power transmission using an elliptical receive coil. Results of simulations using a high-frequency structure simulator were compared to actual measurement results. The simulations showed that the transmission efficiency could be maintained relatively stable even if the alignment between the transmitting and receiving coils was changed to some extent. When the centre of the receiving coil was perfectly aligned with the centre of the transmitting coil, the transmission efficiency was in the maximum; however, the degree of decrease in the transmission efficiency was small even if the centre of the receiving coil moved by ±10 mm from the centre of the transmitting coil. Therefore, it is expected that the performance of the wireless power transmission system will not be degraded significantly even if perfect alignment is not maintained. Animal experiments confirmed good ECG signals for the simulation conditions. The results suggested a standardized application method of wireless transmission in the utilization of wireless power for implantable sensors.

  12. Are Evolution and the Intracellular Innate Immune System Key Determinants in HIV Transmission?

    Science.gov (United States)

    Sumner, Rebecca P.; Thorne, Lucy G.; Fink, Doug L.; Khan, Hataf; Milne, Richard S.; Towers, Greg J.

    2017-01-01

    HIV-1 is the single most important sexually transmitted disease in humans from a global health perspective. Among human lentiviruses, HIV-1 M group has uniquely achieved pandemic levels of human-to-human transmission. The requirement to transmit between hosts likely provides the strongest selective forces on a virus, as without transmission, there can be no new infections within a host population. Our perspective is that evolution of all of the virus–host interactions, which are inherited and perpetuated from host-to-host, must be consistent with transmission. For example, CXCR4 use, which often evolves late in infection, does not favor transmission and is therefore lost when a virus transmits to a new host. Thus, transmission inevitably influences all aspects of virus biology, including interactions with the innate immune system, and dictates the biological niche in which the virus exists in the host. A viable viral niche typically does not select features that disfavor transmission. The innate immune response represents a significant selective pressure during the transmission process. In fact, all viruses must antagonize and/or evade the mechanisms of the host innate and adaptive immune systems that they encounter. We believe that viewing host–virus interactions from a transmission perspective helps us understand the mechanistic details of antiviral immunity and viral escape. This is particularly true for the innate immune system, which typically acts from the very earliest stages of the host–virus interaction, and must be bypassed to achieve successful infection. With this in mind, here we review the innate sensing of HIV, the consequent downstream signaling cascades and the viral restriction that results. The centrality of these mechanisms to host defense is illustrated by the array of countermeasures that HIV deploys to escape them, despite the coding constraint of a 10 kb genome. We consider evasion strategies in detail, in particular the role of the

  13. Theoretical and experimental comparison of an ultra-high-speed laser data transmission system

    Science.gov (United States)

    Tycz, M.

    1973-01-01

    The performance of a digital optical data transmission system is specified by the probability that the system erroneously decides a signal has or has not been transmitted. Two factors which induce signal fading and thereby decrease system performance are atmospheric scintillation and transmitter pointing inaccuracy. A channel simulator was developed that is capable of producing the effects of both atmospheric scintillation and the transmitter pointing problem for a neodymium-yag optical data transmission systems. Comparison of data taken from the modulated intensity of a beam having been transmitted through the channel simulator with experimental data from GEOS-B argon laser transmission through the atmosphere to a low earth-orbiting satellite indicates that the modulated signal intensity is log-normal to the degree of measured atmospheric scintillation.

  14. Development of Wireless Data Transmission System for the Monitoring in Geological Disposal of Radioactive Waste - 12063

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Kei; Eto, Jiro; Tanabe, Hiromi [Radioactive Waste Management Funding and Research Center - RWMC, Tokyo (Japan); Esaki, Taichi; Takamura, Hisashi; Suyama, Yasuhiro [Kajima Corporation, Tokyo (Japan)

    2012-07-01

    The authors have been developing a wireless data transmission system to monitor the performance of a geological disposal system for radioactive waste. The system's concepts, advantages, and a recent development focused on reducing transmitter size to suit narrow spaces such as bentonite buffers and boreholes. A wireless transmitter with a built-in temperature sensor and a connector for external sensors has been developed, measuring 130 mm in length and 50 mm in diameter. The capability of the transmitter was confirmed by transmission tests on the ground and in a bentonite block. (authors)

  15. Design and Evaluation of a Microcomputer-Based Radiological Image Transmission System

    Science.gov (United States)

    Skinner, F.; Cerva, J.; Rappaport, W.; Bregman, H.

    1980-01-01

    The MITRE Corporation is investigating the technical, operational, and economic aspects of transmission of radiological images over narrowband telecommunications lines. To this end, an experiment has been conducted to determine the accuracy of the findings and the diagnoses made by radiologists viewing these digitized images. A microcomputer-controlled transmission and image processing system was designed and implemented to provide the test-bed for the evaluation. This paper provides background information on teleradiology, describes the design of the test-bed system, the evaluation methodology and preliminary results, and MITRE's future plans for the design and implementation of a field test system.

  16. Airborne network system for the transmission of reconnaissance image data

    Science.gov (United States)

    Schmitt, Dirk-Roger; Doergeloh, Heinrich; Fries, Jochen; Keil, Heiko; Wetjen, Wilfried; Kleindienst, Siegfried

    2000-11-01

    Airborne network systems to transmit reconnaissance data from UAVs have been investigated. An airborne experimental system has been developed as test bed to investigate different concepts of the communication between UAV sensor platform, relay platform and ground station. It is based on an Eurocopter BO 105 helicopter and a Dornier DO 228 aircraft. The helicopter is utilized as sensor platform and is equipped with an IR video sensor. It has been demonstrated that video reconnaissance images can be transmitted through a distance of 500 km using the relay platform.

  17. Signal transmission by vibrational resonance in one-way coupled bistable systems.

    Science.gov (United States)

    Yao, Chenggui; Zhan, Meng

    2010-06-01

    Low-frequency signal transmission in one-way coupled bistable systems subject to a high-frequency force is studied. Two cases including the high-frequency force on all sites (case 1) and only on the first site (case 2) are considered. In these two cases, vibrational resonance induced by the high-frequency force can play an active role to effectively improve the signal transmission, and undamped signal transmission can be found in a broad parameter region. The combinative action of injected low-frequency signal, high-frequency driving, and coupling is of importance. Our findings suggest that high-frequency signal could be properly used in low-frequency signal transmission, and especially the implementation of high-frequency force simply on the first site for case 2 is meaningful for its simplicity and high efficiency.

  18. Dynamic Responses and Vibration Control of the Transmission Tower-Line System: A State-of-the-Art Review

    Science.gov (United States)

    Chen, Bo; Guo, Wei-hua; Li, Peng-yun; Xie, Wen-ping

    2014-01-01

    This paper presented an overview on the dynamic analysis and control of the transmission tower-line system in the past forty years. The challenges and future developing trends in the dynamic analysis and mitigation of the transmission tower-line system under dynamic excitations are also put forward. It also reviews the analytical models and approaches of the transmission tower, transmission lines, and transmission tower-line systems, respectively, which contain the theoretical model, finite element (FE) model and the equivalent model; shows the advances in wind responses of the transmission tower-line system, which contains the dynamic effects under common wind loading, tornado, downburst, and typhoon; and discusses the dynamic responses under earthquake and ice loads, respectively. The vibration control of the transmission tower-line system is also reviewed, which includes the magnetorheological dampers, friction dampers, tuned mass dampers, and pounding tuned mass dampers. PMID:25105161

  19. Dynamic responses and vibration control of the transmission tower-line system: a state-of-the-art review.

    Science.gov (United States)

    Chen, Bo; Guo, Wei-hua; Li, Peng-yun; Xie, Wen-ping

    2014-01-01

    This paper presented an overview on the dynamic analysis and control of the transmission tower-line system in the past forty years. The challenges and future developing trends in the dynamic analysis and mitigation of the transmission tower-line system under dynamic excitations are also put forward. It also reviews the analytical models and approaches of the transmission tower, transmission lines, and transmission tower-line systems, respectively, which contain the theoretical model, finite element (FE) model and the equivalent model; shows the advances in wind responses of the transmission tower-line system, which contains the dynamic effects under common wind loading, tornado, downburst, and typhoon; and discusses the dynamic responses under earthquake and ice loads, respectively. The vibration control of the transmission tower-line system is also reviewed, which includes the magnetorheological dampers, friction dampers, tuned mass dampers, and pounding tuned mass dampers.

  20. Sensor, method and system of monitoring transmission lines

    Science.gov (United States)

    Syracuse, Steven J.; Clark, Roy; Halverson, Peter G.; Tesche, Frederick M.; Barlow, Charles V.

    2012-10-02

    An apparatus, method, and system for measuring the magnetic field produced by phase conductors in multi-phase power lines. The magnetic field measurements are used to determine the current load on the conductors. The magnetic fields are sensed by coils placed sufficiently proximate the lines to measure the voltage induced in the coils by the field without touching the lines. The x and y components of the magnetic fields are used to calculate the conductor sag, and then the sag data, along with the field strength data, can be used to calculate the current load on the line and the phase of the current. The sag calculations of this invention are independent of line voltage and line current measurements. The system applies a computerized fitter routine to measured and sampled voltages on the coils to accurately determine the values of parameters associated with the overhead phase conductors.

  1. Portable light transmission measuring system for preserved corneas

    Directory of Open Access Journals (Sweden)

    de Jesus Gabriel

    2005-12-01

    Full Text Available Abstract Background The authors have developed a small portable device for the objective measurement of the transparency of corneas stored in preservative medium, for use by eye banks in evaluation prior to transplantation. Methods The optical system consists of a white light, lenses, and pinholes that collimate the white light beams and illuminate the cornea in its preservative medium, and an optical filter (400–700 nm that selects the range of the wavelength of interest. A sensor detects the light that passes through the cornea, and the average corneal transparency is displayed. In order to obtain only the tissue transparency, an electronic circuit was built to detect a baseline input of the preservative medium prior to the measurement of corneal transparency. The operation of the system involves three steps: adjusting the "0 %" transmittance of the instrument, determining the "100 %" transmittance of the system, and finally measuring the transparency of the preserved cornea inside the storage medium. Results Fifty selected corneas were evaluated. Each cornea was submitted to three evaluation methods: subjective classification of transparency through a slit lamp, quantification of the transmittance of light using a corneal spectrophotometer previously developed, and measurement of transparency with the portable device. Conclusion By comparing the three methods and using the expertise of eye bank trained personnel, a table for quantifying corneal transparency with the new device has been developed. The correlation factor between the corneal spectrophotometer and the new device is 0,99813, leading to a system that is able to standardize transparency measurements of preserved corneas, which is currently done subjectively.

  2. Effect Through Broadcasting System Access Point For Video Transmission

    Directory of Open Access Journals (Sweden)

    Leni Marlina

    2015-08-01

    Full Text Available Most universities are already implementing wired and wireless network that is used to access integrated information systems and the Internet. At present it is important to do research on the influence of the broadcasting system through the access point for video transmitter learning in the university area. At every university computer network through the access point must also use the cable in its implementation. These networks require cables that will connect and transmit data from one computer to another computer. While wireless networks of computers connected through radio waves. This research will be a test or assessment of how the influence of the network using the WLAN access point for video broadcasting means learning from the server to the client. Instructional video broadcasting from the server to the client via the access point will be used for video broadcasting means of learning. This study aims to understand how to build a wireless network by using an access point. It also builds a computer server as instructional videos supporting software that can be used for video server that will be emitted by broadcasting via the access point and establish a system of transmitting video from the server to the client via the access point.

  3. Reliability worth applied to transmission expansion planning based on ant colony system

    Energy Technology Data Exchange (ETDEWEB)

    Leite da Silva, Armando M.; Rezende, Leandro S. [Institute of Electric Systems and Energy, Federal University of Itajuba, UNIFEI (Brazil); da Fonseca Manso, Luiz A.; de Resende, Leonidas C. [Department of Electrical Engineering, Federal University of Sao Joao del Rei, UFSJ (Brazil)

    2010-12-15

    This paper proposes a new methodology to solve transmission expansion planning (TEP) problems in power system, based on the metaheuristic ant colony optimisation (ACO). The TEP problem includes the search for the least cost solution, bearing in mind investment cost and reliability worth. Reliability worth is considered through the assessment of the interruption costs represented by the index LOLC - loss of load cost. The focus of this work is the development of a tool for the multi-stage planning of transmission systems and how reliability aspects can influence on the decision-making process. The applications of the proposed methodology are illustrated through case studies carried out using a test system and a real sub-transmission network. (author)

  4. Network information analysis reveals risk perception transmission in a behaviour-influenza dynamics system.

    Science.gov (United States)

    Liao, C-M; You, S-H; Cheng, Y-H

    2015-01-01

    Influenza poses a significant public health burden worldwide. Understanding how and to what extent people would change their behaviour in response to influenza outbreaks is critical for formulating public health policies. We incorporated the information-theoretic framework into a behaviour-influenza (BI) transmission dynamics system in order to understand the effects of individual behavioural change on influenza epidemics. We showed that information transmission of risk perception played a crucial role in the spread of health-seeking behaviour throughout influenza epidemics. Here a network BI model provides a new approach for understanding the risk perception spread and human behavioural change during disease outbreaks. Our study allows simultaneous consideration of epidemiological, psychological, and social factors as predictors of individual perception rates in behaviour-disease transmission systems. We suggest that a monitoring system with precise information on risk perception should be constructed to effectively promote health behaviours in preparation for emerging disease outbreaks.

  5. Extraordinary optical transmission through multi-layered systems of corrugated metallic thin films.

    Science.gov (United States)

    Gan, Choon How; Gbur, Greg

    2009-10-26

    Optical transmission through multi-layered systems of corrugated metallic thin films is investigated by rigorous electromagnetic simulations based on an exact Green tensor method. Compared to a single metal slab of equivalent thickness and volume, it was found that the multi-layered system can significantly impede the field decay, often leading to transmission greater than that expected from the Fabry-Perot resonance-like behavior exhibited by subwavelength slits in a single slab. Extraordinary optical transmission is also observable for systems of layers whose combined thicknesses are much greater than the skin depth of the metal. Structures consisting of up to five layers with a net thickness of 500 nm for the metal films were considered in our study. These findings demonstrate that an appreciable fraction of the optical power that is incident on the thin metal films can be transmitted over distances greater than their skin depth using plasmonic resonances.

  6. A Data Transmission Technique for Personal Health Systems

    Directory of Open Access Journals (Sweden)

    Jih-Fu Tu

    2013-01-01

    Full Text Available We used the modular technique to design a personal health data transmitter (PHDT that is composed of the following components: (1 the core is an embedded signal chip, (2 three kinds of transmutation modules such as USB, RF, and UART, (3 an I2C interface is used to acquire the users data, and (4 through Internet it links to the cloud server to store the personal-health data. By the experiment, we find that the modular manner is feasible, stable of functional, integral, and accurate, while it is exploited to design the PHDT. For the experiment, we present each module algorithm to find that our system is very helpful to people.

  7. Route-asymmetrical light transmission of a fiber-chip-fiber optomechanical system

    DEFF Research Database (Denmark)

    Liu, Li; Ding, Yunhong; Cai, Xinlun

    2016-01-01

    . Employing a fiber-chip-fiber optomechanical system, our scheme has successfully achieved a broad operation bandwidth of at least 24 nm and an ultra-high route-asymmetrical transmission ratio (RATR) up to 63 dB. The route-asymmetrical device has been demonstrated effectively with not only the continuous...... effect opens up a new opportunity and method for route-asymmetrical light transmission. Moreover, this research may have important applications in all-optical systems, such as the optical limiters and ultra-low loss switches....

  8. Higher order capacity statistics of multi-hop transmission systems over Rayleigh fading channels

    KAUST Repository

    Yilmaz, Ferkan

    2012-03-01

    In this paper, we present an exact analytical expression to evaluate the higher order statistics of the channel capacity for amplify and forward (AF) multihop transmission systems operating over Rayleigh fading channels. Furthermore, we present simple and efficient closed-form expression to the higher order moments of the channel capacity of dual hop transmission system with Rayleigh fading channels. In order to analyze the behavior of the higher order capacity statistics and investigate the usefulness of the mathematical analysis, some selected numerical and simulation results are presented. Our results are found to be in perfect agreement. © 2012 IEEE.

  9. Model, Characterization, and Analysis of Steady-State Security Region in AC/DC Power System with a Large Amount of Renewable Energy

    Directory of Open Access Journals (Sweden)

    Zhong Chen

    2017-08-01

    Full Text Available A conventional steady-state power flow security check only implements point-by-point assessment, which cannot provide a security margin for system operation. The concept of a steady-state security region is proposed to effectively tackle this problem. Considering that the commissioning of the increasing number of HVDC (High Voltage Direct Current and the fluctuation of renewable energy have significantly affected the operation and control of a conventional AC system, the definition of the steady-state security region of the AC/DC power system is proposed in this paper based on the AC/DC power flow calculation model including LCC/VSC (Line Commutated Converter/Voltage Sourced Converter-HVDC transmission and various AC/DC constraints, and hence the application of the security region is extended. In order to ensure that the proposed security region can accurately provide global security information of the power system under the fluctuations of renewable energy, this paper presents four methods (i.e., a screening method of effective boundary surfaces, a fitting method of boundary surfaces, a safety judging method, and a calculation method of distances and corrected distance between the steady-state operating point and the effective boundary surfaces based on the relation analysis between the steady-state security region geometry and constraints. Also, the physical meaning and probability analysis of the corrected distance are presented. Finally, a case study is demonstrated to test the feasibility of the proposed methods.

  10. A flexible millimeter-wave radio-over-fiber system for various transmission bit rate

    Science.gov (United States)

    Yang, Tao; Gao, Mingyi; Qian, Jiaqin; Zhang, Junfeng; Chen, Wei

    2017-11-01

    In this paper, we propose a flexible scheme to generate millimeter-waves (MMWs) for millimeter-wave radio-over-fiber (MMW-RoF) system. The proposed scheme has two configurations to adapt to various transmission bit rate by slightly rearranging the allocation of the system. The main structure of the system is cascaded LiNbO3 Mach-Zehnder modulators (LiNbO3-MZMs). The first configuration is cost effective method, where we utilize a wavelength division multiplexing de-multiplexer (WDM Demux) and an optical splitter (OS) to generate two unmodulated optical signals and a modulated optical signal. Each unmodulated optical signal and the modulated signal will form an optical single sideband (OSSB) modulation and therefore we simultaneously achieve a Q-band (45 GHz) and a V-band (60 GHz) MMWs in the receiver. The bit-error-ratio (BER) curves show that the power penalties of 45 GHz and 60 GHz are 0.6 dB and 1.1 dB at a BER of 1 × 10-9 with 2.5 Gb/s transmission data rate and 50 km fiber transmission distances. The second configuration can accommodate high bit rate, where few optical devices is rearranged to only generate a 60 GHz MMW with 40 Gb/s 4 quadrature amplitude modulation orthogonal frequency division multiplexing (4-QAM OFDM) signals. The power penalty is 1.1 dB at a BER of 1 × 10-9 with 50 km fiber transmission distances. Therefore, the proposed scheme can flexibly generate either two Q&V-band MMWs (45 GHz and 60 GHz) for the applications of the low data-rate transmission systems or one V-band MMW (60 GHz) for the applications of the high data-rate transmission systems.

  11. Comprehensive Benefit Evaluation of the Wind-PV-ES and Transmission Hybrid Power System Consideration of System Functionality and Proportionality

    Directory of Open Access Journals (Sweden)

    Huizheng Ji

    2017-01-01

    Full Text Available In the background of decreasing fossil fuels and increasing environmental pollution, the wind-photovoltaic energy storage and transmission hybrid power system (or called the wind-PV-ES and transmission hybrid system has become a strategic choice to achieve energy sustainability. However, the comprehensive benefit evaluation of such a combined power system is in a relatively blank state in China, which will hinder the reasonable and orderly development of this station. Four parts, the technical performance, economic benefit, ecological impact and social benefit, are considered in this paper, and a multi-angle evaluation index system of the wind-PV-ES and transmission system is designed. The projection pursuit model is used to evaluated system functionality conventionally; relative entropy theory is used to evaluate the system functionality simultaneously; and a comprehensive benefit evaluation model of the technique for order preference by similar to ideal solution (TOPSIS considering both system functionality and proportionality is constructed. Finally, the national demonstration station of the wind-PV-ES-transmission system is taken as an example to testify to the practicability and validity of the evaluation index system and model.

  12. Detectable signals of episodic risk effects on acute HIV transmission: strategies for analyzing transmission systems using genetic data.

    Science.gov (United States)

    Alam, Shah Jamal; Zhang, Xinyu; Romero-Severson, Ethan Obie; Henry, Christopher; Zhong, Lin; Volz, Erik M; Brenner, Bluma G; Koopman, James S

    2013-03-01

    Episodic high-risk sexual behavior is common and can have a profound effect on HIV transmission. In a model of HIV transmission among men who have sex with men (MSM), changing the frequency, duration and contact rates of high-risk episodes can take endemic prevalence from zero to 50% and more than double transmissions during acute HIV infection (AHI). Undirected test and treat could be inefficient in the presence of strong episodic risk effects. Partner services approaches that use a variety of control options will be likely to have better effects under these conditions, but the question remains: What data will reveal if a population is experiencing episodic risk effects? HIV sequence data from Montreal reveals genetic clusters whose size distribution stabilizes over time and reflects the size distribution of acute infection outbreaks (AIOs). Surveillance provides complementary behavioral data. In order to use both types of data efficiently, it is essential to examine aspects of models that affect both the episodic risk effects and the shape of transmission trees. As a demonstration, we use a deterministic compartmental model of episodic risk to explore the determinants of the fraction of transmissions during acute HIV infection (AHI) at the endemic equilibrium. We use a corresponding individual-based model to observe AIO size distributions and patterns of transmission within AIO. Episodic risk parameters determining whether AHI transmission trees had longer chains, more clustered transmissions from single individuals, or different mixes of these were explored. Encouragingly for parameter estimation, AIO size distributions reflected the frequency of transmissions from acute infection across divergent parameter sets. Our results show that episodic risk dynamics influence both the size and duration of acute infection outbreaks, thus providing a possible link between genetic cluster size distributions and episodic risk dynamics. Copyright © 2012 Elsevier B.V. All

  13. Transmission Congestion Management using a Wind Integrated Compressed Air Energy Storage System

    Directory of Open Access Journals (Sweden)

    S. Gope

    2017-08-01

    Full Text Available Transmission congestion is a vital problem in the power system security and reliability sector. To ensure the stable operation of the system, a congestion free power network is desirable. In this paper, a new Congestion Management (CM technique, the Wind integrated Compressed Air Energy Storage (WCAES system is used to alleviate transmission congestion and to minimize congestion mitigation cost. The CM problem has been solved by using the Generator Sensitivity Factor (GSF and the Bus Sensitivity Factor (BSF. BSF is used for finding the optimal location of WCAES in the system. GSF with a Moth Flame Optimization (MFO algorithm is used for rescheduling the generators to alleviate congestion and to minimize congestion cost by improving security margin. The impact of the WCAES system is tested with a 39 bus system. To validate this approach, the same problem has been solved with a Particle Swarm Optimization (PSO algorithm and the obtained results are compared with the ones from the MFO algorithm.

  14. Study on Seismic Control of Power Transmission Tower-Line Coupled System under Multicomponent Excitations

    Directory of Open Access Journals (Sweden)

    Li Tian

    2013-01-01

    Full Text Available The seismic control of power transmission tower-line coupled system subjected to multicomponent excitations is studied in this paper. The schematic of tuned mass damper is introduced, and equations of motion of a system with tuned mass damper under multi-component excitations are proposed. Three-dimensional finite tower-line system models are created based on practical engineering in studying the response of this system without and with control. The time domain analysis takes into account geometric nonlinearity due to finite deformation. The optimal design of the transmission tower-line system with tuned mass damper is obtained according to different mass ratio. The effects of wave travel, coherency loss, and different site conditions on the system without and with control are investigated, respectively.

  15. The steady SRS analysis theory of DWDM transmission system in single-mode silica fiber

    Science.gov (United States)

    Gong, Jia-Min; Zuo, Xu; Zhao, Yun

    2015-09-01

    The formal solution for the couple equations of the stimulated Raman scattering (SRS) with different loss coefficients in the DWDM transmission system was discussed. The variation of each signal photon flux along the transmission distance is shown clearly by the formal solution. Then, the analytical solution is obtained from the formal solution when the loss coefficient is the same. Simultaneously, the analytical solution of the small-signal model is derived, too. We also proposed a novel algorithm according to the formal solution, and verified its correctness by showing that the curves for them are basically in coincidence. The result has a certain significance for study on DWDM transmission system and Raman fiber amplifier.

  16. Influence of Transmitting Pointing Errors on High Speed WDM-AMI-Is-OWC Transmission System

    Science.gov (United States)

    Shatnawi, Abdallah Ahmad; Bin Mohd Warip, Mohd Nazri; Safar, Anuar Mat

    2017-12-01

    Inter-satellite communication is one of the revolutionary techniques that can be used to transmit the high speed date between satellites. However, space turbulences such as transmitting pointing errors play a significant role while designing inter-satellite communication systems. Those turbulences cause shutdown of inter-satellite link due to increase of attenuation during data transmission through link. The present work aims to develop an integrated data transmission system incorporating alternate mark inversion (AMI), wavelength division multiplexing (WDM), and polarization interleaving (PI) scheme for transmitting data 160 Gbps over inter-satellite link of 1,000 km under the influence of space turbulences. The performance of the integrated data transmission of 160 Gbps data up to 1,000 km will be evaluated under the influence of space turbulences by means of signal to noise ratio (SNR), total received power, bit error rate and eye diagram.

  17. Transmission Performance Analysis of Fiber Optical Parametric Amplifiers for WDM System

    Directory of Open Access Journals (Sweden)

    Xiaohong Jiang

    2009-01-01

    Full Text Available A numerical analysis is presented on the long-haul wavelength-division multiplexing (WDM transmission system employing fiber-optic parametric amplifier (FOPA cascades based on one-pump FOPA model with Raman Effect taken into account. The end-to-end equalization scheme is applied to optimize the system features in terms of proper output powers and signal-to-noise ratios (SNRs in all the channels. The numerical results show that—through adjusting the fiber spans along with the number of FOPAs as well as the channel powers at the terminals in a prescribed way—the transmission distance and system performance can be optimized. By comparing the results generated by different lengths of fiber span, we come to the optimal span length to achieve the best transmission performance. Furthermore, we make a comparison among the long-haul WDM transmission systems employing different inline amplifiers, namely, FOPA, erbium-doped fiber amplifier (EDFA, and Fiber Raman Amplifier (FRA. FOPA demonstrates its advantage over the other two in terms of system features.

  18. A method of applying two-pump system in automatic transmissions for energy conservation

    Directory of Open Access Journals (Sweden)

    Peng Dong

    2015-06-01

    Full Text Available In order to improve the hydraulic efficiency, modern automatic transmissions tend to apply electric oil pump in their hydraulic system. The electric oil pump can support the mechanical oil pump for cooling, lubrication, and maintaining the line pressure at low engine speeds. In addition, the start–stop function can be realized by means of the electric oil pump; thus, the fuel consumption can be further reduced. This article proposes a method of applying two-pump system (one electric oil pump and one mechanical oil pump in automatic transmissions based on the forward driving simulation. A mathematical model for calculating the transmission power loss is developed. The power loss transfers to heat which requires oil flow for cooling and lubrication. A leakage model is developed to calculate the leakage of the hydraulic system. In order to satisfy the flow requirement, a flow-based control strategy for the electric oil pump is developed. Simulation results of different driving cycles show that there is a best combination of the size of electric oil pump and the size of mechanical oil pump with respect to the optimal energy conservation. Besides, the two-pump system can also satisfy the requirement of the start–stop function. This research is extremely valuable for the forward design of a two-pump system in automatic transmissions with respect to energy conservation and start–stop function.

  19. Development of BLDC Electric Motor Control System In Hydraulic Servo Drive Based on Variable Hydrostatic Transmission

    Directory of Open Access Journals (Sweden)

    O. I. Tarasov

    2014-01-01

    Full Text Available Modern robotic systems require the use of servo drives. Owing to encoder and negative feedback these drives ensure highly accurate motion parameters. In case of autonomous systems drives must also have high power characteristics. Moreover, in most cases, it was impossible to select the motor so that the speed and torque on its shaft were in compliance with those of required by the actuator. To match these parameters different types of reducers are used. The article justifies and considers a selection criterion of the gear ratios for such transmission. For clarity, there is an example of selecting a motor and a gear for above transmission, taking into account the proposed criterion. In addition, the article discusses the advantages of using hydrostatic transmission in the drive, which monitors the angular position of the output level, in comparison with a mechanical gearbox. Due to the fact that, at the moment, BLDC motors have the best power characteristics, such a servo drive requires a special control system that will take into account the features of variable hydrostatic transmission and electric BLDC motor. Therefore, the paper proposes a structure of such a system and set out the principles of its construction. Various embodiments of sensor types that may be used in this system and their installation scheme explained.

  20. Uprating Transmission Lines through the use of an innovative real-time monitoring system

    OpenAIRE

    CLOET, Eric; Lilien, Jean-Louis

    2011-01-01

    This paper describes a brand new method of real-time monitoring of overhead transmission lines. The method makes use of what is called the “Ampacimon” system. The system uses an Ampacimon module, which is a real time monitoring device that deduces the sag by vibration analysis without the need for any line data or environmental data. The Ampacimon system has been proven to be accurate within a sag error margin of ±2%. Peer reviewed

  1. The Design of Data Transmission Terminal in Remote Warning Control System Based on CDMA 1X Network

    Directory of Open Access Journals (Sweden)

    Dan CHEN

    2014-03-01

    Full Text Available This study proposes a framework of data transmission terminal in remote warning control system based on CDMA 1X network. According to the functional requirements of wireless broadband communication system, the hardware interfaces and software of the CDMA 1X data transmission terminal are designed detailedly and the system is implemented using wireless access and embedded development technologies. It has good applicability and portability so that various wireless data transmissions can be achieved by replacing the data source module.

  2. Advanced Error-Control Coding Methods Enhance Reliability of Transmission and Storage Data Systems

    Directory of Open Access Journals (Sweden)

    K. Vlcek

    2003-04-01

    Full Text Available Iterative coding systems are currently being proposed and acceptedfor many future systems as next generation wireless transmission andstorage systems. The text gives an overview of the state of the art initerative decoded FEC (Forward Error-Correction error-control systems.Such systems can typically achieve capacity to within a fraction of adB at unprecedented low complexities. Using a single code requires verylong code words, and consequently very complex coding system. One wayaround the problem of achieving very low error probabilities is turbocoding (TC application. A general model of concatenated coding systemis shown - an algorithm of turbo codes is given in this paper.

  3. A force transmission system based on a tulip-shaped electrostatic clutch for haptic display devices

    Science.gov (United States)

    Sasaki, Hikaru; Shikida, Mitsuhiro; Sato, Kazuo

    2006-12-01

    This paper describes a novel type of force transmission system for haptic display devices. The system consists of an array of end-effecter elements, a force/displacement transmitter and a single actuator producing a large force/displacement. It has tulip-shaped electrostatic clutch devices to distribute the force/displacement from the actuator among the individual end effecters. The specifications of three components were determined to stimulate touched human fingers. The components were fabricated by using micro-electromechanical systems and conventional machining technologies, and finally they were assembled by hand. The performance of the assembled transmission system was experimentally examined and it was confirmed that each projection in the arrayed end effecters could be moved individually. The actuator in a system whose total size was only 3.0 cm × 3.0 cm × 4.0 cm produced a 600 mN force and displaced individual array elements by 18 µm.

  4. Hardware efficient frequency domain equalization in few-mode fiber coherent transmission systems

    Science.gov (United States)

    Pan, Z.; He, Xuan; Weng, Yi

    2013-12-01

    Few-mode fiber (FMF) transmission system has become an emerging technology to overcome next capacity crunch. To compensate the large accumulated differential mode group delay (DMGD) and random mode coupling in FMF transmission systems, frequency domain least mean square (FD-LMS) algorithm has been proposed and proven as the most hardware efficient approach. Except for the hardware complexity, convergence speed is another major consideration of adaptive FD-LMS algorithm, especially in FMF system with large accumulated DMGD. We propose two algorithms to improve the convergence speed of the adaptive FD-LMS in FMF transmission systems. One is signal power spectrum density (PSD) dependent adaptive algorithm, which adopts variable step size that is the reciprocal of the power level in each frequency bin. The other is noise power directed adaptive FD-LMS algorithm, which adopts the step size of each frequency bin rendering the posterior errors that will converge to background noise in additive white Gaussian noise channel. Our simulation results show that, in a 3000 km FMF transmission system with 35-ps/km DMGD and optical signal to noise ratio (OSNR) of 14 dB, the noise power directed algorithm and PSD dependent algorithm can improve the convergence speed by 54% and 35% over conventional adaptive FD-LMS algorithm with negligible increase in hardware complexity. We also proposed a complexity reduced single-stage adaptive equalizer for compensating both chromatic dispersion (CD) and DMGD simultaneously. The single-stage method can save 6% complex multiplication over conventional two-stage equalization method in a 1000 km FMF transmission system with 76-ps/km DMGD.

  5. Temporal spying and concealing process in fibre-optic data transmission systems through polarization bypass

    National Research Council Canada - National Science Library

    Bony, P Y; Guasoni, M; Morin, P; Sugny, D; Picozzi, A; Jauslin, H R; Pitois, S; Fatome, J

    2014-01-01

    .... Here we report the first experimental demonstration of perpetual temporal spying and blinding process of optical data in fibre-optic transmission line based on polarization bypass. We successfully characterize the performance of our system by alternatively copying and then concealing 100% of a 10-Gb s(-1) transmitted signal.

  6. 47 CFR 74.795 - Digital low power TV and TV translator transmission system facilities.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Digital low power TV and TV translator... DISTRIBUTIONAL SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.795 Digital low power TV and TV translator transmission system facilities. (a) A digital low power TV or TV translator station shall operate...

  7. 76 FR 44320 - Buckeye Power, Inc. v. American Transmission Systems, Incorporated; Notice of Complaint

    Science.gov (United States)

    2011-07-25

    ... Energy Regulatory Commission Buckeye Power, Inc. v. American Transmission Systems, Incorporated; Notice of Complaint Take notice that on July 18, 2011, pursuant to sections 206 and 306 of the Federal Power... (Commission), Buckeye Power, Inc. (Buckeye or Complainant) filed a formal complaint against American...

  8. 75 FR 81264 - Critical Path Transmission, LLC; Clear Power, LLC; v. California Independent System Operator, Inc...

    Science.gov (United States)

    2010-12-27

    ... Energy Regulatory Commission Critical Path Transmission, LLC; Clear Power, LLC; v. California Independent System Operator, Inc.; Notice of Complaint December 17, 2010. Take notice that on December 14, 2010... (Commission), 18 CFR 385.206 (2010) and sections 206 and 306 of the Federal Power Act, 16 U.S.C. 824e and 825e...

  9. Modelling of structure-borne sound transmission via pipe systems to building structures. A framework

    NARCIS (Netherlands)

    Jagt, G.S. van der; Martin, H.J.

    1999-01-01

    Prediction of the structure-borne sound transmission via wastewater and watersupply pipe systems to building structures is not possible. By combining deterministic and statistical methods calculations for the whole audible frequency range seem possible. In this paper a framework for the theoretical

  10. Stability analysis of transmission system with high penetration of distributed generation

    NARCIS (Netherlands)

    Reza, M.

    2006-01-01

    Nowadays, interest in generating electricity using decentralized generators of relatively small scale ('distributed generation', DG) is increasing. This work deals with the impact of implementing DG on the transmission system transient stability, with the emphasis on a potential transition from a

  11. Symplectic Hamiltonina formulation of Transmission Line Systems with Boundary Energy Flow

    NARCIS (Netherlands)

    van der Schaft, A.J.; Jeltsema, D

    2007-01-01

    The classical Langrangian and Hamiltonian formulation of an electrical transmission line is reviewed and extended to allow for varying boundary conditions. The method is based on the definition of an infinite-dimensional analogue of the affine Langrangian and Hamiltonian input-output systems

  12. Symplectic Hamiltonian Formulation of Transmission Line Systems with Boundary Energy Flow

    NARCIS (Netherlands)

    Jeltsema, Dimitri; Schaft, Arjan van der

    2008-01-01

    The classical Lagrangian and Hamiltonian formulation of an electrical transmission line is reviewed and extended to allow for varying boundary conditions. This extension is based on the definition of an infinite-dimensional analogue of the affine Lagrangian and Hamiltonian input-output systems

  13. Lagrangian and Hamiltonian Formulation of Transmission Line Systems with Boundary Energy Flow

    NARCIS (Netherlands)

    Jeltsema, Dimitri; Schaft, Arjan J. van der

    The classical Lagrangian and Hamiltonian formulation of an electrical transmission line is reviewed and extended to allow for varying boundary conditions, The method is based on the definition of an infinite-dimensional analogue of the affine Lagrangian and Hamiltonian input-output systems

  14. A Seismic Transmission System for Continuous Monitoring of the Lithosphere : A Proposition

    NARCIS (Netherlands)

    Unger, R.

    2002-01-01

    The main objective of this thesis is to enhance earthquake prediction feasibility. We present the concept and the design layout of a novel seismic transmission system capable of continuously monitoring the Lithosphere for changes in Earth physics parameters governing seismic wave propagation.

  15. Secure Analog Data Transmission Based on Rössler Chaotic System Behavior

    Directory of Open Access Journals (Sweden)

    Daniel CURIAC

    2000-12-01

    Full Text Available This paper describes a new methodology for increasing the security of analog data transmission based on a mixture of the original analog signal with one of the state variables of Rössler chaotic system. The method is described emphasizing on the practical implementation aspects.

  16. Preliminary design of high-power wave-guide/transmission system ...

    Indian Academy of Sciences (India)

    Home; Journals; Pramana – Journal of Physics; Volume 59; Issue 5. Preliminary design of high-power wave-guide/transmission system for multimegawatt CW requirements of 100 MeV proton LINAC. Purushottam Shrivastava Y D Wanmode P R Hannurkar. Volume 59 Issue 5 November 2002 pp 829-834 ...

  17. Multiagent System-Based Distributed Coordinated Control for Radial DC Microgrid Considering Transmission Time Delays

    DEFF Research Database (Denmark)

    Dou, Chun-Xia; Yue, Dong; Guerrero, Josep M.

    2017-01-01

    This paper focuses on a multi-agent based distributed coordinated control for radial DC microgrid considering trans-mission time delays. Firstly, a two-level multi-agent system is constructed, where local control is formulated based on local states and executed by means of the first-level agent...

  18. Alternatives for Primary Frequency Control Contribution from Wind Power Plants Connected to VSC-HVDC Intertie

    DEFF Research Database (Denmark)

    Laukhamar, Andreas Grøsvik; Zeni, Lorenzo; Sørensen, Poul Ejnar

    With the increasing share of renewables in the electric power systems, the transmission system operators (TSOs) need more balancing power to even out short- and long-term variability of the intermittent electric power sources such as solar and wind power. In light of this, this paper investigates...

  19. The competitive role of the transmission system in price-regulated power industries

    Energy Technology Data Exchange (ETDEWEB)

    Arellano, M. Soledad [Department of Industrial Engineering, Universidad de Chile (Chile); Serra, Pablo [Department of Economics, Universidad de Chile (Chile)

    2008-07-15

    This note shows how the transmission system can enhance competition in price-regulated power industries, thus extending earlier findings reported in the literature for deregulated industries. In the context of a two-technology, price-regulated power industry, we show that the interconnection of two markets initially supplied by a different monopoly reduces market power and raises welfare. We also show that the capacity of the transmission line plays a key role in determining whether market equilibrium lies closer to competition or monopoly. (author)

  20. Observation of electromagnetically induced transparency-like transmission in terahertz asymmetric waveguide-cavities systems.

    Science.gov (United States)

    Chen, Lin; Gao, Chunmei; Xu, Jiaming; Zang, Xiaofei; Cai, Bin; Zhu, Yiming

    2013-05-01

    Electromagnetically induced transparency (EIT)-like transmission was demonstrated in terahertz asymmetric parallel plate waveguides with two identical cavities. By shifting the position of the bottom cavity from the symmetric position in the propagation direction, both the phases of the propagating wave at resonances and the coupling strengths between two cavities are changed, resulting in exciting the additional asymmetric resonance and manipulating the detuning of two different resonant frequencies. The transparent peak between two resonances comes from the cancelation of symmetric and asymmetric resonances. We also use the physical picture of excitation of quasi-dark mode to explain this EIT-like transmission, which is similar to the metamaterial systems.

  1. 146-GHz millimeter-wave radio-over-fiber photonic wireless transmission system.

    Science.gov (United States)

    Fice, M J; Rouvalis, E; van Dijk, F; Accard, A; Lelarge, F; Renaud, C C; Carpintero, G; Seeds, A J

    2012-01-16

    We report the experimental implementation of a wireless transmission system with a 146-GHz carrier frequency which is generated by optical heterodyning the two modes from a monolithically integrated quantum dash dual-DFB source. The monolithic structure of the device and the inherent low noise characteristics of quantum dash gain material allow us to demonstrate the transmission of a 1 Gbps ON-OFF keyed data signal with the two wavelengths in a free-running state at 146-GHz carrier wave frequency. The tuning range of the device fully covers the W-band (75 - 110 GHz) and the F-band (90 - 140 GHz).

  2. Three-phase receiving coil of wireless power transmission system for gastrointestinal robot

    Science.gov (United States)

    Jia, Z. W.; Jiang, T.; Liu, Y.

    2017-11-01

    Power shortage is the bottleneck for the wide application of gastrointestinal (GI) robot. Owing to the limited volume and free change of orientation of the receiving set in GI trace, the optimal of receiving set is the key point to promote the transmission efficiency of wireless power transmission system. A new type of receiving set, similar to the winding of three-phase asynchronous motor, is presented and compared with the original three-dimensional orthogonal coil. Considering the given volume and the space utilization ratio, the three-phase and the three-orthogonal ones are the parameters which are optimized and compared. Both the transmission efficiency and stability are analyzed and verified by in vitro experiments. Animal experiments show that the new one could provide at least 420 mW power in volume of Φ11 × 13mm with a uniformity of 78.3% for the GI robot.

  3. Perfect transmission through Anderson localized systems mediated by a cluster of localized modes.

    Science.gov (United States)

    Choi, Wonjun; Park, Q-Han; Choi, Wonshik

    2012-08-27

    In a strongly scattering medium where Anderson localization takes place, constructive interference of local non-propagating waves dominate over the incoherent addition of propagating waves. This results in the disappearance of propagating waves within the medium, which significantly attenuates energy transmission. In this numerical study performed in the optical regime, we systematically found resonance modes, called eigenchannels, of a 2-D Anderson localized system that allow for the near-perfect energy transmission. We observed that the internal field distribution of these eigenchannels exhibit dense clustering of localized modes. This strongly suggests that the clustered resonance modes facilitate long-range energy flow of local waves. Our study explicitly elucidates the interplay between wave localization and transmission enhancement in the Anderson localization regime.

  4. Factors influencing efficiency of laser wireless power transmission system for micro unmanned aerial vehicles

    Science.gov (United States)

    Liu, Xiaoguang; Hua, Wenshen; Liu, Xun

    2014-12-01

    Micro unmanned aerial vehicle, mostly powered by electricity, plays an important role in many military and civil applications, e.g. military detection, communication relay et al. But restricted endurance ability severely limits its applications. To solve the problem, laser wireless power transmission system is proposed. However, overall efficiency of the system is quite low. This paper describes basic structure of laser wireless power transmission system and its working process. The system consists of two major modules: a high power laser source transmitting energy and a photovoltaic receiver converting optical energy into electricity. Then factors influencing efficiency of the system are analyzed. It suggests that electro-optical efficiency of laser, atmospheric impact on laser beam and photo-electric efficiency of photovoltaic receiver play significant role in overall efficiency of the system. Atmospheric impact on laser beam mostly derived from refraction, absorption, scattering and turbulence effects, leads to drop in energy and quality of laser beam. Efficiency of photovoltaic receiver is affected by photovoltaic materials. In addition, matching degree between intensity distribution of laser beam and layout of photovoltaic receiver also obviously influence efficiency of photovoltaic receiver. Experiment results suggest that under non-uniform laser beam illumination, efficiency of photovoltaic receiver mostly depends on layout of photovoltaic receiver. Through optimizing the layout of photovoltaic receiver based on intensity distribution of laser beam, output power is significantly improved. The analysis may help to take corresponding measures to alleviate negative effects of these factors and improve performance of laser wireless power transmission system.

  5. Adaptive transmission schemes for MISO spectrum sharing systems: Tradeoffs and performance analysis

    KAUST Repository

    Bouida, Zied

    2014-10-01

    In this paper, we propose a number of adaptive transmission techniques in order to improve the performance of the secondary link in a spectrum sharing system. We first introduce the concept of minimum-selection maximum ratio transmission (MS-MRT) as an adaptive variation of the existing MRT (MRT) technique. While in MRT all available antennas are used for transmission, MS-MRT uses the minimum subset of antennas verifying both the interference constraint (IC) to the primary user and the bit error rate (BER) requirements. Similar to MRT, MS-MRT assumes that perfect channel state information (CSI) is available at the secondary transmitter (ST), which makes this scheme challenging from a practical point of view. To overcome this challenge, we propose another transmission technique based on orthogonal space-time block codes with transmit antenna selection (TAS). This technique uses the full-rate full-diversity Alamouti scheme in order to maximize the secondary\\'s transmission rate. The performance of these techniques is analyzed in terms of the average spectral efficiency (ASE), average number of transmit antennas, average delay, average BER, and outage performance. In order to give the motivation behind these analytical results, the tradeoffs offered by the proposed schemes are summarized and then demonstrated through several numerical examples.

  6. Transmission performance analysis of WDM systems based on bismuth-doped phosphate glass fiber amplifiers

    Science.gov (United States)

    Ji, Jianhua; Huang, Qian; Wang, Ke; Xu, Ming; Jiang, Chun

    2018-01-01

    In this paper transmission performance of Allwave fiber WDM systems cascaded by bismuth-doped phosphate glass fiber amplifiers pumped by 808 nm lasers is analyzed for the first time, to the best of our knowledge. The rate and power propagation equations of a three-level system are used to model the signal amplification and noise figure in the doped fibers. The simulation results show that the channels in the 1460-1470 nm wavelength region in 32 × 40 Gbit/s WDM system with 10 nm channel space can reach a BER less than 1 × 10-9 with the transmission distance more than 600 km, but when the channel space is reduced to 1 nm, the performance of the system is degraded greatly.

  7. Ellipsometric determination of polarization-dependent transmission in resonant feedback systems.

    Science.gov (United States)

    Holzapfel, Wolfgang; Neuschaefer-Rube, Ulrich; Braasch, Jan Christian; Mahdavi, Nejat

    2007-03-20

    The polarization-dependent transmission of a basic anisotropic feedback system (Fabry-Perot resonator) is mathematically modeled by means of the Jones-matrix formalism. Detailed numerical simulations of the resonance case are performed. Small phase anisotropies as well as small polarization-dependent losses of the resonator components can be extremely amplified by resonant feedback. The amplification factors depend on the magnitudes of amplitude and phase anisotropy and their mutual interactions as well as on the polarization-independent system parameters (forward transmission, system feedback). However, for higher phase anisotropies, saturation effects occur and, therefore, the anisotropy amplification factors decrease. Our experimental investigations applying anisotropic Fabry-Perot resonators in different ellipsometer systems confirm the predicted amplification of phase and loss anisotropies in resonance operation.

  8. Bound states and perfect transmission scattering states in P T -symmetric open quantum systems

    Science.gov (United States)

    Garmon, Savannah; Gianfreda, Mariagiovanna; Hatano, Naomichi

    2014-03-01

    We study the point spectrum and transmission scattering spectrum in P T -symmetric open quantum systems containing balanced regions of energy amplification and attenuation, using tight-binding chains with matching sink and source sites as prototype models. For a given system geometry, we write the boundary conditions that permit scattering state and bound state solutions with wave functions that likewise satisfy P T symmetry; we further demonstrate the P T -symmetric scattering states give rise to perfect transmission through the scattering region. We also discuss bound states in continuum and other spectral effects that may be discovered in P T -symmetric open quantum systems. Finally we discuss the potential for experimental realization of our models in systems containing whispering gallery mode resonators with balanced loss and gain. S. G. acknowledges support from the Japan Society for the Promotion of Science.

  9. Learning from the blackouts. Transmission system security in competitive electricity markets

    Energy Technology Data Exchange (ETDEWEB)

    none

    2005-07-01

    Electricity market reform has fundamentally changed the environment for maintaining reliable and secure power supplies. Growing inter-regional trade has placed new demands on transmission systems, creating a more integrated and dynamic network environment with new real-time challenges for reliable and secure transmission system operation. Despite these fundamental changes, system operating rules and practices remain largely unchanged. The major blackouts of 2003 and 2004 raised searching questions about the appropriateness of these arrangements. Management of system security needs to be transformed to maintain reliable electricity services in this more dynamic operating environment. These challenges raise fundamental issues for policymakers. This publication presents case studies drawn from recent large-scale blackouts in Europe, North America, and Australia. It concludes that a comprehensive, integrated policy response is required to avoid preventable large-scale blackouts in the future.

  10. A full-duplex lightwave transmission system with an innovative VCSEL-based PM-to-IM converter.

    Science.gov (United States)

    Lin, Chun-Yu; Lu, Hai-Han; Chang, Ching-Hung; Li, Chung-Yi; Jhang, Tai-Wei; Ruan, Sheng-Siang; Wu, Kuan-Hung

    2014-04-21

    A full-duplex lightwave transmission system employing innovative VCSEL-based PM-to-IM converters to deliver intensity-modulated CATV/phase-modulated RoF/intensity-remodulated RoF signals over two 40-km SMFs links is proposed and demonstrated. To be the first one of employing VCSEL-based PM-to-IM converters in full-duplex lightwave transmission systems, the downstream light is successfully intensity-remodulated with RoF signal for up-link transmission. Good performances of CNR/CSO/CTB are achieved for downstream CATV signal transmission, and low BER values are obtained for both downstream and upstream RoF signals transmissions. Our proposed systems present brilliant performances in delivering hybrid CATV and RoF signals. Such a full-duplex lightwave transmission system would be very attractive for fiber trunk applications to provide broadband integrated services.

  11. Insulator and Clerance Requirements in Overhead Line Transmission Systems without Shield Wires

    DEFF Research Database (Denmark)

    Sørensen, Thomas Kjærsgaard; Holbøll, Joachim

    2008-01-01

    This paper theoretically examines the required insulation lengths and clearances in 400 kV overhead line systems when not making use of ground wires as lightning protection. The influence of lightning strikes to the system is investigated based on dynamic transmission line simulations of a 400 k......V section in PSCAD/EMTDC. The performance of the system without shield wires is considerably deteriorated if no steps are taken to increase the insulation level of the system. However by increasing the insulator lengths and clearances in the system greatly the performance can be improved....

  12. Power Control of Low Frequency AC Transmission Systems Using Cycloconverters with Virtual Synchronous Generator Control

    OpenAIRE

    Achara Pichetjamroen; Toshifumi Ise

    2016-01-01

    This paper is focused on the application of a multi-terminal line-commutated converter-type low frequency AC transmission system (MTLF) using a cycloconverter by applying a new power control scheme for multi-terminal operation. With the virtual synchronous generator (VSG) control scheme, the transmitting power among the multi-terminal system can be accomplished without a communication link for frequency synchronization in each terminal. The details of the proposed control scheme are explained...

  13. Compact transmission system using single-sideband modulation of light for quantum cryptography.

    Science.gov (United States)

    Duraffourg, L; Merolla, J M; Goedgebuer, J P; Mazurenko, Y; Rhodes, W T

    2001-09-15

    We report a new transmission that can be used for quantum key distribution. The system uses single-sideband-modulated light in an implementation of the BB84 quantum cryptography protocol. The system is formed by two integrated unbalanced Mach-Zehnder interferometers and is based on interference between phase-modulated sidebands in the spectral domain. Experiments show that high interference visibility can be obtained.

  14. Evaluation of systems for reducing the transmission of Porcine reproductive and respiratory syndrome virus by aerosol

    OpenAIRE

    Dee, Scott A.; Batista, Laura; Deen, John; Pijoan, Carlos

    2006-01-01

    The purpose of this study was to compare 3 methods for the reduction of aerosol transmission of Porcine reproductive and respiratory syndrome virus (PRRSV): high-efficiency particulate air (HEPA) filtration, low-cost filtration, and ultraviolet light (UV) irradiation. The HEPA-filtration system involved a pre-filter screen, a bag filter (EU8 rating), and a HEPA filter (EU13 rating). The low-cost-filtration system contained mosquito netting (pre-filter), a fiberglass furnace filter, and an ele...

  15. System for Relay Protection Command Transmission by High-Voltage Lines

    Directory of Open Access Journals (Sweden)

    D. A. Yenkov

    2009-01-01

    Full Text Available Development of a system for relay protection command transmission by high-voltage lines is shown in the paper. The paper describes an architecture of the system, main principles of its operation, engineering aspects of the development that is accomplishment of technical requirements, solution of trades-off. Justification of the selected design and an algorithm of the reliable detection of relay protection signals are given in the paper.

  16. Two-channel MIMO-OCC transmission system on a smartphone

    Science.gov (United States)

    Kowalczyk, M.

    2017-08-01

    The possibility of using MIMO technique for purpose of increasing information capacity of optical camera communication systems (OCC) has been experimentally proved in regard to a smartphone used as a receiver. Among others, a successful 2-channel transmission at a distance longer than 4 m has been presented. By use of traditional modulation schemes the throughputs which can be achieved in the OCC systems are typically only a few dozen bits per second. The MIMO is promising technique to overcome this limitation.

  17. Transmission Power Determination Based on Power Amplifier Operations in Large-Scale MIMO-OFDM Systems

    OpenAIRE

    Byung Moo Lee; Youngok Kim

    2017-01-01

    This paper presents a method to determine transmission power based on power amplifier (PA) operations in order to improve the energy efficiency (EE) of a large-scale (LS) Multiple Input Multiple Output (MIMO)-OFDM system, which is a multi-carrier multiple antenna system with a large amount of transmitter (TX) antennas. Regarding the EE improvement, we propose two kinds of PA operation schemes: increasing the effective TX power (ITXP) and reducing the PA power consumption (RPC) assuming that a...

  18. Raptor code-enabled reliable data transmission for in-vehicle power line communication systems with impulsive noise

    OpenAIRE

    Xu, Zhaopeng; Yang, Chuanchuan; Tan, Zhongwei; Sheng, Zhengguo

    2017-01-01

    With the rapid development of in-vehicle data transmission systems, the power line communication (PLC) technology is considered as a good alternative due to the reduction of cable harness. However, PLC suffers from severe impulse noise which hinders the correct reception of data packets and hence leads to a poor transmission performance. In this paper, we propose a raptor code-enabled data transmission scheme for different traffic classes in in-vehicle PLC systems. Simulation results show tha...

  19. A long distance voice transmission system based on the white light LED

    Science.gov (United States)

    Tian, Chunyu; Wei, Chang; Wang, Yulian; Wang, Dachi; Yu, Benli; Xu, Feng

    2017-10-01

    A long distance voice transmission system based on a visible light communication technology (VLCT) is proposed in the paper. Our proposed system includes transmitter, receiver and the voice signal processing of single chip microcomputer. In the compact-sized LED transmitter, we use on-off-keying and not-return-to-zero (OOK-NRZ) to easily realize high speed modulation, and then systematic complexity is reduced. A voice transmission system, which possesses the properties of the low-noise and wide modulation band, is achieved by the design of high efficiency receiving optical path and using filters to reduce noise from the surrounding light. To improve the speed of the signal processing, we use single chip microcomputer to code and decode voice signal. Furthermore, serial peripheral interface (SPI) is adopted to accurately transmit voice signal data. The test results of our proposed system show that the transmission distance of this system is more than100 meters with the maximum data rate of 1.5 Mbit/s and a SNR of 30dB. This system has many advantages, such as simple construction, low cost and strong practicality. Therefore, it has extensive application prospect in the fields of the emergency communication and indoor wireless communication, etc.

  20. Space Weather, Geomagnetic Disturbances and Impact on the High-Voltage Transmission Systems

    Science.gov (United States)

    Pullkkinen, A.

    2011-01-01

    Geomagnetically induced currents (GIC) affecting the performance of high-voltage power transmission systems are one of the most significant hazards space weather poses on the operability of critical US infrastructure. The severity of the threat was emphasized, for example, in two recent reports: the National Research Council (NRC) report "Severe Space Weather Events--Understanding Societal and Economic Impacts: A Workshop Report" and the North American Electric Reliability Corporation (NERC) report "HighImpact, Low-Frequency Event Risk to the North American Bulk Power System." The NRC and NERC reports demonstrated the important national security dimension of space weather and GIC and called for comprehensive actions to forecast and mitigate the hazard. In this paper we will give a brief overview of space weather storms and accompanying geomagnetic storm events that lead to GIC. We will also review the fundamental principles of how GIC can impact the power transmission systems. Space weather has been a subject of great scientific advances that have changed the wonder of the past to a quantitative field of physics with true predictive power of today. NASA's Solar Shield system aimed at forecasting of GIC in the North American high-voltage power transmission system can be considered as one of the ultimate fruits of those advances. We will review the fundamental principles of the Solar Shield system and provide our view of the way forward in the science of GIC.

  1. Expected Range of Cooperation Between Transmission System Operators and Distribution System Operators After Implementation of ENTSO-E Grid Codes

    Directory of Open Access Journals (Sweden)

    Tomasz Pakulski

    2015-06-01

    Full Text Available The authors present the prospects of cooperation between transmission system operators (TSO and distribution system operators (DSO after entry into force ENTSO-E (European Network of Transmission System Operators for Electricity grid codes. New areas of DSO activities, associated with offering TSO aggregated services for national power system regulation based on the regulation resources connected to the distribution grid, and services on the distribution system level as part of the creation of local balancing areas (LBA are presented. The paper also presents the possibilities of providing ancillary services by different types of distributed generation sources in the distribution network. The LBA concept, which involves integrated management of local regulation resources including generation, demand, and energy storage is described. The options of the renewable energy sources (RES using for voltage and reactive power control in the distribution network with the use of wind farms (WF connected to the distribution system are characterized.

  2. Priority Control Strategy of VSC-MTDC System for Integrating Wind Power

    Directory of Open Access Journals (Sweden)

    Wen-ning Yan

    2015-01-01

    Full Text Available For the obvious advantages in integrating wind power, multiterminal HVDC transmission system (VSC-MTDC is widely used. The priority control strategy is proposed in this paper considering the penetration rate of wind power for the AC grid. The strategy aims to solve the problems of power allocation and DC voltage control of the DC system. The main advantage of this strategy is that the demands for wind power of different areas can be satisfied and a power reference for the wind power trade can also be provided when wind farms transmit active power to several AC grids through the DC network. The objective is that power is well distributed according to the output power of wind farm with the demand of AC system and satisfactory control performance of DC voltage is obtained.

  3. Digital model for harmonic interactions in AC/DC/AC systems

    Energy Technology Data Exchange (ETDEWEB)

    Guarini, A.P.; Rangel, R.D.; Pilotto, L.A.S.; Pinto, R.J.; Passos Junior, R. [Centro de Pesquisas de Energia Eletrica (CEPEL), Rio de Janeiro, RJ (Brazil)

    1994-12-31

    The main purpose of this paper is to present a model for calculation of HVdc converter harmonics taking into account the influence of the harmonic interactions between the ac systems in dc link transmissions. The ideas and methodologies used in the model development take into account the dc current ripple and ac voltage distortion in the ac systems. The theory of switching functions is applied to contemplate for the frequency conversions between the ac and dc sides, in an iterative process. It is possible then to obtain, even in balanced situations, non-characteristic harmonics that are produced by frequencies originated in the other terminal, which can be significant in a strongly coupled system, such as back-to-back configuration. (author) 9 refs., 3 figs.

  4. An examination of the vibration transmissibility of the hand-arm system in three orthogonal directions

    Science.gov (United States)

    Welcome, Daniel E.; Dong, Ren G.; Xu, Xueyan S.; Warren, Christopher; McDowell, Thomas W.; Wu, John Z.

    2015-01-01

    The objective of this study is to enhance the understanding of the vibration transmission in the hand-arm system in three orthogonal directions (X, Y, and Z). For the first time, the transmitted vibrations distributed on the entire hand-arm system exposed in the three orthogonal directions via a 3-D vibration test system were measured using a 3-D laser vibrometer. Seven adult male subjects participated in the experiment. This study confirms that the vibration transmissibility generally decreased with the increase in distance from the hand and it varied with the vibration direction. Specifically, to the upper arm and shoulder, only moderate vibration transmission was measured in the test frequency range (16 to 500 Hz), and virtually no transmission was measured in the frequency range higher than 50 Hz. The resonance vibration on the forearm was primarily in the range of 16–30 Hz with the peak amplitude of approximately 1.5 times of the input vibration amplitude. The major resonance on the dorsal surfaces of the hand and wrist occurred at around 30–40 Hz and, in the Y direction, with peak amplitude of more than 2.5 times of the input amplitude. At higher than 50 Hz, vibration transmission was effectively limited to the hand and fingers. A major finger resonance was observed at around 100 Hz in the X and Y directions and around 200 Hz in the Z direction. In the fingers, the resonance magnitude in the Z direction was generally the lowest, and the resonance magnitude in the Y direction was generally the highest with the resonance amplitude of 3 times the input vibration, which was similar to the transmissibility at the wrist and hand dorsum. The implications of the results are discussed. Relevance to industry Prolonged, intensive exposure to hand-transmitted vibration could result in hand-arm vibration syndrome. While the syndrome's precise mechanisms remain unclear, the characterization of the vibration transmissibility of the system in the three orthogonal

  5. Evaluation and Verification of Channel Transmission Characteristics of Human Body for Optimizing Data Transmission Rate in Electrostatic-Coupling Intra Body Communication System: A Comparative Analysis.

    Science.gov (United States)

    Tseng, Yuhwai; Su, Chauchin; Ho, Yingchieh

    2016-01-01

    Intra-body communication is a new wireless scheme for transmitting signals through the human body. Understanding the transmission characteristics of the human body is therefore becoming increasingly important. Electrostatic-coupling intra-body communication system in a ground-free situation that integrate electronic products that are discretely located on individuals, such as mobile phones, PDAs, wearable computers, and biomedical sensors, are of particular interest. The human body is modeled as a simplified Resistor-Capacitor network. A virtual ground between the transmitter and receiver in the system is represented by a resister-capacitor network. Value of its resistance and capacitance are determined from a system perspective. The system is characterized by using a mathematical unit step function in digital baseband transmission scheme with and without Manchester code. As a result, the signal-to-noise and to-intersymbol-interference ratios are improved by manipulating the load resistor. The data transmission rate of the system is optimized. A battery-powered transmitter and receiver are developed to validate the proposal. A ground-free system fade signal energy especially for a low-frequency signal limited system transmission rate. The system transmission rate is maximized by simply manipulating the load resistor. Experimental results demonstrate that for a load resistance of 10k-50k Ω, the high-pass 3 dB frequency of the band-pass channel is 400kHz-2MHz in the worst-case scenario. The system allows a Manchester-coded baseband signal to be transmitted at speeds of up to 20M bit per second with signal-to-noise and signal-to-intersymbol-interference ratio of more than 10 dB. The human body can function as a high speed transmission medium with a data transmission rate of 20Mbps in an electrostatic-coupling intra-body communication system. Therefore, a wideband signal can be transmitted directly through the human body with a good signal-to-noise quality of 10 dB if

  6. Evaluation and Verification of Channel Transmission Characteristics of Human Body for Optimizing Data Transmission Rate in Electrostatic-Coupling Intra Body Communication System: A Comparative Analysis

    Science.gov (United States)

    Tseng, Yuhwai; Su, Chauchin; Ho, Yingchieh

    2016-01-01

    Background Intra-body communication is a new wireless scheme for transmitting signals through the human body. Understanding the transmission characteristics of the human body is therefore becoming increasingly important. Electrostatic-coupling intra-body communication system in a ground-free situation that integrate electronic products that are discretely located on individuals, such as mobile phones, PDAs, wearable computers, and biomedical sensors, are of particular interest. Materials and Methods The human body is modeled as a simplified Resistor-Capacitor network. A virtual ground between the transmitter and receiver in the system is represented by a resister-capacitor network. Value of its resistance and capacitance are determined from a system perspective. The system is characterized by using a mathematical unit step function in digital baseband transmission scheme with and without Manchester code. As a result, the signal-to-noise and to-intersymbol-interference ratios are improved by manipulating the load resistor. The data transmission rate of the system is optimized. A battery-powered transmitter and receiver are developed to validate the proposal. Results A ground-free system fade signal energy especially for a low-frequency signal limited system transmission rate. The system transmission rate is maximized by simply manipulating the load resistor. Experimental results demonstrate that for a load resistance of 10k−50k Ω, the high-pass 3 dB frequency of the band-pass channel is 400kHz−2MHz in the worst-case scenario. The system allows a Manchester-coded baseband signal to be transmitted at speeds of up to 20M bit per second with signal-to-noise and signal-to-intersymbol-interference ratio of more than 10 dB. Conclusion The human body can function as a high speed transmission medium with a data transmission rate of 20Mbps in an electrostatic-coupling intra-body communication system. Therefore, a wideband signal can be transmitted directly through the

  7. Evaluation and Verification of Channel Transmission Characteristics of Human Body for Optimizing Data Transmission Rate in Electrostatic-Coupling Intra Body Communication System: A Comparative Analysis.

    Directory of Open Access Journals (Sweden)

    Yuhwai Tseng

    Full Text Available Intra-body communication is a new wireless scheme for transmitting signals through the human body. Understanding the transmission characteristics of the human body is therefore becoming increasingly important. Electrostatic-coupling intra-body communication system in a ground-free situation that integrate electronic products that are discretely located on individuals, such as mobile phones, PDAs, wearable computers, and biomedical sensors, are of particular interest.The human body is modeled as a simplified Resistor-Capacitor network. A virtual ground between the transmitter and receiver in the system is represented by a resister-capacitor network. Value of its resistance and capacitance are determined from a system perspective. The system is characterized by using a mathematical unit step function in digital baseband transmission scheme with and without Manchester code. As a result, the signal-to-noise and to-intersymbol-interference ratios are improved by manipulating the load resistor. The data transmission rate of the system is optimized. A battery-powered transmitter and receiver are developed to validate the proposal.A ground-free system fade signal energy especially for a low-frequency signal limited system transmission rate. The system transmission rate is maximized by simply manipulating the load resistor. Experimental results demonstrate that for a load resistance of 10k-50k Ω, the high-pass 3 dB frequency of the band-pass channel is 400kHz-2MHz in the worst-case scenario. The system allows a Manchester-coded baseband signal to be transmitted at speeds of up to 20M bit per second with signal-to-noise and signal-to-intersymbol-interference ratio of more than 10 dB.The human body can function as a high speed transmission medium with a data transmission rate of 20Mbps in an electrostatic-coupling intra-body communication system. Therefore, a wideband signal can be transmitted directly through the human body with a good signal

  8. Power Control of Low Frequency AC Transmission Systems Using Cycloconverters with Virtual Synchronous Generator Control

    Directory of Open Access Journals (Sweden)

    Achara Pichetjamroen

    2016-12-01

    Full Text Available This paper is focused on the application of a multi-terminal line-commutated converter-type low frequency AC transmission system (MTLF using a cycloconverter by applying a new power control scheme for multi-terminal operation. With the virtual synchronous generator (VSG control scheme, the transmitting power among the multi-terminal system can be accomplished without a communication link for frequency synchronization in each terminal. The details of the proposed control scheme are explained in order to understand the advantages of this method. The configuration of a two-phase low frequency AC transmission system (LFAC is adopted to examine with the proposed control scheme. Simulation results are provided to illustrate the proposed control scheme with respect to the LFAC system’s performance.

  9. Grid connection of active stall wind farms using a VSC based DC transmission system

    DEFF Research Database (Denmark)

    Iov, Florin; Sorensen, Paul; Hansen, Anca-Daniela

    2005-01-01

    are fulfilled. However, the traditional squirrel-cage generators based wind turbines/wind farms directly connected to the grid have less control capabilities. These wind turbines/farms cannot regulate their production and contribute to power system stability. A DC transmission system for connection......Currently, there is an increasing trend to connect large MW wind farms to the transmission system. Requirements that focus on the influence of the farms on the grid stability and power quality, and on the control capabilities of wind farms have already been established. The main trends of modern...... wind turbines/farms are clearly the variable speed operation and a grid connection through a power electronic interface, especially using doubly fed induction generators. Using power electronics the control capabilities of these wind turbines/farms are extended and thus the grid requirements...

  10. All-fiber orbital angular momentum mode generation and transmission system

    Science.gov (United States)

    Heng, Xiaobo; Gan, Jiulin; Zhang, Zhishen; Qian, Qi; Xu, Shanhui; Yang, Zhongmin

    2017-11-01

    We proposed and demonstrated an all-fiber system for generating and transmitting orbital angular momentum (OAM) mode light. A specially designed multi-core fiber (MCF) was used to endow with guide modes different phase change and two tapered transition regions were used for providing low-loss interfaces between different fiber structures. By arranging the refractive index distribution among the multi-cores and controlling the length of MCF, which essentially change the phase difference between the neighboring cores, OAM modes with different topological charge l can be generated selectively. Through two tapered transition regions, the non-OAM mode light can be effectively injected into the MCF and the generated OAM mode light can be easily launched into OAM mode supporting fiber for long distance and high purity transmission. Such an all-fiber OAM mode generation and transmission system owns the merits of flexibility, compactness, portability, and would have practical application value in OAM optical fiber communication systems.

  11. Impact of Transmission on Resource Adequacy in Systems with Wind and Solar Power: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Ibanez, E.; Milligan, M.

    2012-02-01

    Variable generation is on track to become a significant contributor to electric power systems worldwide. Thus, it is important to analyze the effect that renewables will have on the reliability of systems. In this paper we present a new tool being implemented at the National Renewable Energy Laboratory, which allows the inclusion of variable generation in the power system resource adequacy. The tool is used to quantify the potential contribution of transmission to reliability in highly interconnected systems and an example is provided using the Western Interconnection footprint.

  12. A new inductive sensor for online health monitoring of mechanical transmission systems

    DEFF Research Database (Denmark)

    Wang, Chao; Liu, Xiao; Chen, Zhe

    2015-01-01

    Metal debris in lubricating oil contains abundant information regarding the ageing and wear of mechanical transmission systems. The health condition of the lubricated systems can be indicated by the quantity and size of the metal particles, which may provide very early warnings of faults/ failures...... indicates the infancy failure of the system [1-2]. Inductive sensor, which transforms the quantity and size of the particles into the number and magnitude variation of pulses of coil inductance, is widely used in the online metal debris monitoring systems [1-5]....

  13. Three-Phase Fault Currents Evaluation for Nigerian 28-Bus 330kv Transmission System

    Science.gov (United States)

    Adepoju, Gafari A.; Tijani, Muhammed A.; Sanusi, Mufutau A.; Olatunji, Dauda O.

    2012-03-01

    Fault studies are important power system analysis for stable and economical operations of power systems. Faults are categorised as symmetrical and unsymmetrical. In this paper, three-phase symmetrical fault is simulated using the Nigerian 28-Bus, 330kV Transmission Grid. Two different MatLab based programmes were developed; one program was for Load Flow Studies which determines prefault conditions for the power system based on Newton-Raphson method. The other program determines fault current magnitudes for threephase short-circuit on the power system. The information gained from the fault studies can be used for proper relay selections, settings, performances and coordination.

  14. Gas mixing system for imaging of nanomaterials under dynamic environments by environmental transmission electron microscopy.

    Science.gov (United States)

    Akatay, M Cem; Zvinevich, Yury; Baumann, Philipp; Ribeiro, Fabio H; Stach, Eric A

    2014-03-01

    A gas mixing manifold system that is capable of delivering a stable pressure stream of a desired composition of gases into an environmental transmission electron microscope has been developed. The system is designed to provide a stable imaging environment upon changes of either the composition of the gas mixture or upon switching from one gas to another. The design of the system is described and the response of the pressure inside the microscope, the sample temperature, and sample drift in response to flow and composition changes of the system are reported.

  15. Model documentation: Natural gas transmission and distribution model of the National Energy Modeling System. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-02-17

    The Natural Gas Transmission and Distribution Model (NGTDM) is the component of the National Energy Modeling System (NEMS) that is used to represent the domestic natural gas transmission and distribution system. NEMS was developed in the Office of integrated Analysis and Forecasting of the Energy information Administration (EIA). NEMS is the third in a series of computer-based, midterm energy modeling systems used since 1974 by the EIA and its predecessor, the Federal Energy Administration, to analyze domestic energy-economy markets and develop projections. The NGTDM is the model within the NEMS that represents the transmission, distribution, and pricing of natural gas. The model also includes representations of the end-use demand for natural gas, the production of domestic natural gas, and the availability of natural gas traded on the international market based on information received from other NEMS models. The NGTDM determines the flow of natural gas in an aggregate, domestic pipeline network, connecting domestic and foreign supply regions with 12 demand regions. The methodology employed allows the analysis of impacts of regional capacity constraints in the interstate natural gas pipeline network and the identification of pipeline capacity expansion requirements. There is an explicit representation of core and noncore markets for natural gas transmission and distribution services, and the key components of pipeline tariffs are represented in a pricing algorithm. Natural gas pricing and flow patterns are derived by obtaining a market equilibrium across the three main elements of the natural gas market: the supply element, the demand element, and the transmission and distribution network that links them. The NGTDM consists of four modules: the Annual Flow Module, the Capacity F-expansion Module, the Pipeline Tariff Module, and the Distributor Tariff Module. A model abstract is provided in Appendix A.

  16. Design and Realization of a New Signal Security System for Multimedia Data Transmission

    Directory of Open Access Journals (Sweden)

    Hun-Chen Chen

    2003-12-01

    Full Text Available We propose a new signal security system and its VLSI architecture for real-time multimedia data transmission applications. We first define two bit-circulation functions for one-dimensional binary array transformation. Then, we exploit a chaotic system in generating a binary sequence to control the bit-circulation functions defined for performing the successive transformation on the input data. Each eight 8-bit data elements is regarded as a set and is fed into an 8×8 binary matrix being transformed on each row and each column of the matrix by these two bit-circulation functions such that the signal can be transformed into completely disordered data. The features of the proposed design include low computational complexity, regular operations suitable for low-cost VLSI implementation, high data security, and high feasibility for easy integration with commercial multimedia storage and transmission applications. We have performed Matlab simulation to verify the functional correctness of the proposed system. In implementing the system, a low-cost VLSI architecture has been designed, verified, and physically realized based on a 0.35 μm CMOS technology. The implementation results show that the proposed signal security system can achieve 117 Mbytes/s data throughput rate that is fast enough for real-time data protection in multimedia transmission applications.

  17. Design, analysis and modeling of a novel hybrid powertrain system based on hybridized automated manual transmission

    Science.gov (United States)

    Wu, Guang; Dong, Zuomin

    2017-09-01

    Hybrid electric vehicles are widely accepted as a promising short to mid-term technical solution due to noticeably improved efficiency and lower emissions at competitive costs. In recent years, various hybrid powertrain systems were proposed and implemented based on different types of conventional transmission. Power-split system, including Toyota Hybrid System and Ford Hybrid System, are well-known examples. However, their relatively low torque capacity, and the drive of alternative and more advanced designs encouraged other innovative hybrid system designs. In this work, a new type of hybrid powertrain system based hybridized automated manual transmission (HAMT) is proposed. By using the concept of torque gap filler (TGF), this new hybrid powertrain type has the potential to overcome issue of torque gap during gearshift. The HAMT design (patent pending) is described in details, from gear layout and design of gear ratios (EV mode and HEV mode) to torque paths at different gears. As an analytical tool, mutli-body model of vehicle equipped with this HAMT was built to analyze powertrain dynamics at various steady and transient modes. A gearshift was decomposed and analyzed based basic modes. Furthermore, a Simulink-SimDriveline hybrid vehicle model was built for the new transmission, driveline and vehicle modular. Control strategy has also been built to harmonically coordinate different powertrain components to realize TGF function. A vehicle launch simulation test has been completed under 30% of accelerator pedal position to reveal details during gearshift. Simulation results showed that this HAMT can eliminate most torque gap that has been persistent issue of traditional AMT, improving both drivability and performance. This work demonstrated a new type of transmission that features high torque capacity, high efficiency and improved drivability.

  18. Optimization of the transmission system for wavelength routed optical network: trade-off between node complexity and transmission channel utilization

    DEFF Research Database (Denmark)

    Limal, Emmanuel; Hjelme, Dag Roar; Stubkjær, Kristian Elmholdt

    1998-01-01

    We study the influence of the number of wavelengths per fibre and the line bit rate on network dimensions and transmission capacity utilisation for wavelength routed optical transport networks. The networks considered are of European scale, and the traffic matrices used are projections of a traffic...

  19. Linealización de sistemas VSC-HVDC para el diseño de un controlador PI vectorial

    Directory of Open Access Journals (Sweden)

    Nelson Díaz Aldana

    2014-01-01

    Full Text Available Los sistemas VSC-HVDC son muy utilizados para la transmisión de energía en redes de interconexión eléctrica. Uno de los principales problemas que poseen estos sistemas es la complejidad de su modelo matemático, lo que conlleva grandes dificultades para el diseño de controladores que permitan la regulación de parámetros como la tensión DC de transmisión, así como la potencia activa y reactiva del sistema VSC-HVDC. En este artículo se presenta la linealización de un sistema VSC-HVDC y el posterior diseño de un controlador lineal PI vectorial a partir del modelo linealizado. Adicionalmente, se proponen dos estrategias para la validación de este tipo de controladores, la primera consiste en un único controlador PI para regular los estados del sistema para cada VSC, la segunda consiste en el diseño de controladores PI vectoriales independientes para la regulación de cada estado del VSC.

  20. Real-time all-optical OFDM transmission system based on time-domain optical fourier transformation

    DEFF Research Database (Denmark)

    Guan, Pengyu; Kong, Deming; Røge, Kasper Meldgaard

    2014-01-01

    We propose a novel simple all-optical OFDM transmission system based on time-domain OFT using time-lenses. A real-time 160 Gbit/s DPSK OFDM transmission with 16 decorrelated data subcarriers is successfully demonstrated over 100 km.......We propose a novel simple all-optical OFDM transmission system based on time-domain OFT using time-lenses. A real-time 160 Gbit/s DPSK OFDM transmission with 16 decorrelated data subcarriers is successfully demonstrated over 100 km....

  1. Seismic Response of Power Transmission Tower-Line System Subjected to Spatially Varying Ground Motions

    Directory of Open Access Journals (Sweden)

    Li Tian

    2010-01-01

    Full Text Available The behavior of power transmission tower-line system subjected to spatially varying base excitations is studied in this paper. The transmission towers are modeled by beam elements while the transmission lines are modeled by cable elements that account for the nonlinear geometry of the cables. The real multistation data from SMART-1 are used to analyze the system response subjected to spatially varying ground motions. The seismic input waves for vertical and horizontal ground motions are also generated based on the Code for Design of Seismic of Electrical Installations. Both the incoherency of seismic waves and wave travel effects are accounted for. The nonlinear time history analytical method is used in the analysis. The effects of boundary conditions, ground motion spatial variations, the incident angle of the seismic wave, coherency loss, and wave travel on the system are investigated. The results show that the uniform ground motion at all supports of system does not provide the most critical case for the response calculations.

  2. 128 Gb/s TWDM PON system using dispersion-supported transmission method

    Science.gov (United States)

    Bindhaiq, Salem; Zulkifli, Nadiatulhuda; Supa'at, Abusahmah M.; Idrus, Sevia M.; Salleh, M. S.

    2017-11-01

    Time and wavelength division multiplexed passive optical network (TWDM-PON) trend is considered as the most extraordinary trend of the next generation solution to accommodate exponential traffic growth for converged new services. In this paper, we briefly review recent progress on TWDM-PON system through the use of low cost directly modulated lasers (DMLs) transmission for various line rate transmissions to date. Furthermore, through simulation, we propose and evaluate a cost effective way to upgrade TWDM-PON up to a symmetric capacity of 128 Gb/s using fiber Bragg gratings (FBGs) in optical line terminal (OLT) as a paramount dispersion manager in high speed light-wave systems in both upstream and downstream directions. A low cost and potential chirpless directed modulated grating laser (DMGL) is employed for downstream link and DML with a single delay-interferometer (DI) is employed for upstream link. After illustrating the demonstrated system architecture and configuration, we present the results and analysis to prove the system feasibility. The results show that a successful transmission is achieved over 40 km single mode fiber with a power budget of 33.7 dB, which could support 1:256 splitting ratio.

  3. Design of a telemetry system based on wireless power transmission for physiological parameter monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Zhiwei, E-mail: jiayege@hotmail.com [College of Electrical and Information Engineering, Changsha University of Science and Technology, Changsha (China); Yan, Guozheng; Zhu, Bingquan [820 Institute, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai (China)

    2015-04-15

    An implanted telemetry system for experimental animals with or without anaesthesia can be used to continuously monitor physiological parameters. This system is significant not only in the study of organisms but also in the evaluation of drug efficacy, artificial organs, and auxiliary devices. The system is composed of a miniature electronic capsule, a wireless power transmission module, a data-recording device, and a processing module. An electrocardiograph, a temperature sensor, and a pressure sensor are integrated in the miniature electronic capsule, in which the signals are transmitted in vitro by wireless communication after filtering, amplification, and A/D sampling. To overcome the power shortage of batteries, a wireless power transmission module based on electromagnetic induction was designed. The transmitting coil of a rectangular-section solenoid and a 3D receiving coil are proposed according to stability and safety constraints. Experiments show that at least 150 mW of power could pick up on the load in a volume of Φ10.5 mm × 11 mm, with a transmission efficiency of 2.56%. Vivisection experiments verified the feasibility of the integrated radio-telemetry system.

  4. A unified modeling and control design for precision transmission system with friction and backlash

    Directory of Open Access Journals (Sweden)

    Xiulan Bao

    2016-05-01

    Full Text Available The structural flexibility, nonlinear friction, and backlash are the major factors limiting the control performance of precision transmission systems. If uncompensated, these factors compromise the positioning and tracking accuracy of precision transmission systems and even cause limit cycles and oscillation. In this article, a framework for integrated design from dynamic modeling to controller design is proposed. A multi-state dynamic model is presented, which can unify the modeling for a multi-state, discontinuous system including the motor state, the motion state, the mechanical contact state, and the friction state. Then, a control design method related to the dynamic modeling using perturbation separation of the model parameters is presented. Using the proposed modeling method, a continuous dynamic model is established to include all different partition models. The model comprehensively describes the mechanical and electrical characteristics of the precision transmission system. A robust controller is designed using the proposed control method. Experimental results demonstrate that the proposed modeling method is accurate and the proposed control method significantly improves accuracy and robustness of the controller compared to traditional control methods.

  5. Safety awareness educational topics for the construction of power transmission systems with smart grid technologies

    Directory of Open Access Journals (Sweden)

    Bryan Hubbard

    2013-09-01

    Full Text Available Power transmission facilities in the U.S. are undergoing a transformation due to the increased use of distributed generation sources such as wind and solar power.  The current power grid system is also antiquated and in need of substantial retrofits to make it more efficient and reliable.  The new energy transmission system being designed and built to optimize power delivery is known as “Smart Grid”.  The increased activity in the construction of power transmission facilities and installation of new technologies into the current power system raises potential safety concerns.  Existing construction management curriculum may include general information about safety training, but does not typically include information about this specialized sector.  The objective of this study was to work with industry to identify key safety topics appropriate for inclusion in an introductory industrial construction course.  Results of interviews with industry identified numerous hazards that are not typically covered in typical construction curricula.  A joint undergraduate and graduate course in industrial construction was created to address these and additional concepts. A survey of the students was performed to determine the effectiveness of the course and also to determine their thoughts about the smart grid technologies and safety training. Information on electrical system hazards is presented along with results of the student surveys.

  6. Cloud-based shaft torque estimation for electric vehicle equipped with integrated motor-transmission system

    Science.gov (United States)

    Zhu, Xiaoyuan; Zhang, Hui; Yang, Bo; Zhang, Guichen

    2018-01-01

    In order to improve oscillation damping control performance as well as gear shift quality of electric vehicle equipped with integrated motor-transmission system, a cloud-based shaft torque estimation scheme is proposed in this paper by using measurable motor and wheel speed signals transmitted by wireless network. It can help reduce computational burden of onboard controllers and also relief network bandwidth requirement of individual vehicle. Considering possible delays during signal wireless transmission, delay-dependent full-order observer design is proposed to estimate the shaft torque in cloud server. With these random delays modeled by using homogenous Markov chain, robust H∞ performance is adopted to minimize the effect of wireless network-induced delays, signal measurement noise as well as system modeling uncertainties on shaft torque estimation error. Observer parameters are derived by solving linear matrix inequalities, and simulation results using acceleration test and tip-in, tip-out test demonstrate the effectiveness of proposed shaft torque observer design.

  7. Sensor selection of helicopter transmission systems based on physical model and sensitivity analysis

    Directory of Open Access Journals (Sweden)

    Lyu Kehong

    2014-06-01

    Full Text Available In the helicopter transmission systems, it is important to monitor and track the tooth damage evolution using lots of sensors and detection methods. This paper develops a novel approach for sensor selection based on physical model and sensitivity analysis. Firstly, a physical model of tooth damage and mesh stiffness is built. Secondly, some effective condition indicators (CIs are presented, and the optimal CIs set is selected by comparing their test statistics according to Mann–Kendall test. Afterwards, the selected CIs are used to generate a health indicator (HI through sen slop estimator. Then, the sensors are selected according to the monotonic relevance and sensitivity to the damage levels. Finally, the proposed method is verified by the simulation and experimental data. The results show that the approach can provide a guide for health monitoring of helicopter transmission systems, and it is effective to reduce the test cost and improve the system’s reliability.

  8. A low-power high-speed ultra-wideband pulse radio transmission system.

    Science.gov (United States)

    Wei Tang; Culurciello, E

    2009-10-01

    We present a low-power high-speed ultra-wideband (UWB) transmitter with a wireless transmission test platform. The system is specifically designed for low-power high-speed wireless implantable biosensors. The integrated transmitter consists of a compact pulse generator and a modulator. The circuit is fabricated in the 0.5-mum silicon-on-sapphire process and occupies 420 mum times 420 mum silicon area. The transmitter is capable of generating pulses with 1-ns width and the pulse rate can be controlled between 90 MHz and 270 MHz. We built a demonstration/testing system for the transmitter. The transmitter achieves a 14-Mb/s data rate. With 50% duty cycle data, the power consumption of the chip is between 10 mW and 21 mW when the transmission distance is from 3.2 to 4 m. The core circuit size is 70 mum times 130 mum.

  9. Control apparatus for vehicle power transmitting system including continuously variable transmission

    Energy Technology Data Exchange (ETDEWEB)

    Nakawaki, Y.; Numazawa, A.; Hayashi, T.

    1989-06-06

    This patent describes a control apparatus for a power transmitting system for an automotive vehicle, including a continuously variable transmission whose speed ratio is continuously variable, wherein power is transmitted from an engine of the vehicle to drive wheels of the vehicle. The control apparatus consists of: first detector means for detecting a currently required output of the engine; second detector means for detecting a running speed of the vehicle; mode selector means responsive to the first detector means, for selecting one of a continuously variable speed mode in which the speed ratio of the continuously variable transmission is continuously variable transmission is continuously changed, and a stepping shift mode in which the speed ratio is changed in steps, the continuously variable transmission having speed-ratio positions which correspond to the steps, the mode selector means selecting the continuously variable speed mode while the currently required output of the engine detected by the first detector means is equal to or smaller than a predetermined reference value, and selecting the stepping shift mode when the currently required output of the engine exceeds the predetermined reference value during an increase in the detected required output of the engine.

  10. Brain potentials predict learning, transmission and modification of an artificial symbolic system

    DEFF Research Database (Denmark)

    Lumaca, Massimo; Baggio, G.

    2016-01-01

    : as in previous oddball studies, an mismatch negativity (MMN) was elicited by deviant tones. On day 2, participants learned an artificial signaling system from a trained confederate of the experimenters in a coordination game in which five-tone sequences were associated to affective meanings (emotion......-laden pictures of human faces). In a subsequent game with identical structure, participants transmitted and occasionally changed the signaling system learned during the first game. TheMMNlatency from day 1 predicted learning, transmission and structural modification of signaling systems on day 2. Our study...

  11. Cryogenic transmission electron microscopy (cryo-TEM) for studying the morphology of colloidal drug delivery systems

    DEFF Research Database (Denmark)

    Kuntsche, Judith; Horst, Jennifer C; Bunjes, Heike

    2011-01-01

    Cryogenic transmission electron microscopy (cryo-TEM) has evolved into an indispensable tool for the characterization of colloidal drug delivery systems. It can be applied to study the size, shape and internal structure of nanoparticulate carrier systems as well as the overall colloidal composition...... of the corresponding dispersions. This review gives a short overview over the instrumentation used in cryo-TEM experiments and over the sample preparation procedure. Selected examples of cryo-TEM studies on colloidal drug carrier systems, including liposomes, colloidal lipid emulsions, solid lipid nanoparticles...

  12. Shaft torsional oscillation interactions between turbo-generators in parallel in series compensated transmission systems

    Energy Technology Data Exchange (ETDEWEB)

    Mello, F.P. de

    1994-12-31

    Several investigators have raised the possibility of interaction between shaft systems of parallel units, particularly among identical units. The question addressed in this paper is the significance of this interaction between shaft systems of units coupled through the electrical system. A time domain model of two parallels units connected to an infinite bus trough a series compensated transmission is used to evaluate the phenomena. The same model is used to extract pertinent frequency response functions by Fourier processing of pulse response tests from which a frequency response analysis is performed to lend additional insight into the phenomena. (author) 8 refs., 13 figs., 3 tabs.

  13. A Common Definition of the System Operators' Core Activities[Electric Power Transmission System Operator

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-02-15

    In this report a common definition of the system operator's core activities in the Nordic countries is identified and also a list of non-core activities is introduced. As a starting point the common tasks for system responsibility as identified by Nordel has been used for the work. The term TSO (Transmission System Operator) is employed as a common denominator in the report. It is found out that the TSOs carry out common core activities in the roles as a transmission operator, a system operator and a balance settlement responsible. The core activities for the TSO as a transmission network operator are: Maintain the adequate transmission system in the long run and network development plan on the national as well as on the Nordic level using sophisticated analysis and planning methods and tools. Plan the transmission network on the national as well as on the Nordic level utilising new investments, renewal and maintenance of existing network components so that the network is secure to operate and adequate transmission capacity is guaranteed. Aim at timely network expansions using enhanced information exchange between the Nordic TSOs, and on the national level between the TSO and distribution and regional network operators, large consumers and large producers. Secure the technical compatibility with networks across the border and within a country by establishing connection requirements on the national level and ensuring that the national requirements are compatible across the Nordic power system. The core activities for the TSO as a system operator are: Define common technical requirements for the secure system operation using common planning, operation, connection and data exchange procedures. Secure the system operation with the operational planning for the following year by using information exchange between TSOs enabling the TSOs to make the best possible forecast of the global grid situation in order to assess the flows in their network and the available

  14. Signals transmission via RF systems in a sewage treatment plant; Signaluebertragung via Funk im Klaerwerk

    Energy Technology Data Exchange (ETDEWEB)

    Brasas, Joerg [Phoenix Contact Electronics GmbH, Bad Pyrmont (Germany)

    2010-06-15

    The Niersverband is a municipal utility located at Viersen, Germany. It covers an area that is more or less identical with the catchment area of the Niers river and the Niers canal. There are 23 sewage treatment plants, rainwater retention basins and pumping stations transporting the collected water to the sewage treatment plants. For signal transmission between the stations, a Trusted Wireless system via Profibus-DP is used. (orig.)

  15. Adaptive Neurofuzzy Inference System-Based Pollution Severity Prediction of Polymeric Insulators in Power Transmission Lines

    OpenAIRE

    Muniraj, C.; Chandrasekar, S.

    2011-01-01

    This paper presents the prediction of pollution severity of the polymeric insulators used in power transmission lines using adaptive neurofuzzy inference system (ANFIS) model. In this work, laboratory-based pollution performance tests were carried out on 11 kV silicone rubber polymeric insulator under AC voltage at different pollution levels with sodium chloride as a contaminant. Leakage current was measured during the laboratory tests. Time domain and frequency domain characteristics of leak...

  16. 10Gb/s Bang-Bang Clock and Data Recovery (CDR for optical transmission systems

    Directory of Open Access Journals (Sweden)

    N. Dodel

    2005-01-01

    Full Text Available A Bang-Bang Clock-Data Recovery (CDR for 10Gb/s optical transmission systems is presented. A direct modulated architecture is used for the design. Its loop characteristics can be derived using an analogy to Σ Δ theory. The circuit was produced and measured in a commercial 0.25μm BiCMOS technology with a transition frequency fT70=GHz.

  17. A Case Study Of Turkish Transmission System For VoltageDips

    DEFF Research Database (Denmark)

    Inan, E.; Alboyaci, B.; Bak, Claus Leth

    2009-01-01

    Power quality problems usually appear in the form of voltage sags, transients and harmonics. From these three broad categories of power quality problems, voltage dips account the most disturbances experienced by industrial customers. Voltage dips generally refer to instantaneous short-duration vo...... analysis of voltage dip performance of the whole transmission system, is used to compare with results constructed fault statics from SIMPOW DIPS analysis program real data. SIMPOW DIPS software enables to calculate dip frequency for all busses and lines....

  18. Interference Robust Transmission for the Downlink of an OFDM-Based Mobile Communications System

    Directory of Open Access Journals (Sweden)

    Markus Konrad

    2008-01-01

    Full Text Available Radio networks for future mobile communications systems, for example, 3GPP Long-Term Evolution (LTE, are likely to use an orthogonal frequency division multiplexing- (OFDM- based air interface in the downlink with a frequency reuse factor of one to avoid frequency planning. Therefore, system capacity is limited by interference, which is particularly crucial for mobile terminals with a single receive antenna. Nevertheless, next generation mobile communications systems aim at increasing downlink throughput. In this paper, a single antenna interference cancellation (SAIC algorithm is introduced for amplitude-shift keying (ASK modulation schemes in combination with bit-interleaved coded OFDM. By using such a transmission strategy, high gains in comparison to a conventional OFDM transmission with quadrature amplitude modulation (QAM can be achieved. The superior performance of the novel scheme is confirmed by an analytical bit-error probability (BEP analysis of the SAIC receiver for a single interferer, Rayleigh fading, and uncoded transmission. For the practically more relevant multiple interferer case we present an adaptive least-mean-square (LMS and an adaptive recursive least-squares (RLS SAIC algorithm. We show that in particular the RLS approach enables a good tradeoff between performance and complexity and is robust even to multiple interferers.

  19. Scalable Heuristics for Planning, Placement and Sizing of Flexible AC Transmission System Devices

    Energy Technology Data Exchange (ETDEWEB)

    Frolov, Vladmir [Skolkovo Institute of Science and Technology, Skolkovo (Russia); Backhaus, Scott N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Chertkov, Michael [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-07-02

    Aiming to relieve transmission grid congestion and improve or extend feasibility domain of the operations, we build optimization heuristics, generalizing standard AC Optimal Power Flow (OPF), for placement and sizing of Flexible Alternating Current Transmission System (FACTS) devices of the Series Compensation (SC) and Static VAR Compensation (SVC) type. One use of these devices is in resolving the case when the AC OPF solution does not exist because of congestion. Another application is developing a long-term investment strategy for placement and sizing of the SC and SVC devices to reduce operational cost and improve power system operation. SC and SVC devices are represented by modification of the transmission line inductances and reactive power nodal corrections respectively. We find one placement and sizing of FACTs devices for multiple scenarios and optimal settings for each scenario simultaneously. Our solution of the nonlinear and nonconvex generalized AC-OPF consists of building a convergent sequence of convex optimizations containing only linear constraints and shows good computational scaling to larger systems. The approach is illustrated on single- and multi-scenario examples of the Matpower case-30 model.

  20. Evolutions and Challenges towards a Potential Pan-European HVAC/HVDC SuperGrid

    OpenAIRE

    FULLI Gianluca; PURVINS ARTURS; RÜBERG Sven; L’ABBATE Angelo; MIGLIAVACCA, Gianluigi

    2011-01-01

    The European power transmission grid is on the critical path to meet the European Union (EU)’s climate change and energy policy objectives for 2020. This trend is expected to continue also for the years after 2020, in view of ambitious decarbonisation targets by 2050. The main challenge will be the power system integration of very large amounts of variable renewable energy sources (RES), especially wind and also solar, while keeping overall system reliability at acceptable levels, in a libera...

  1. Natural gas transmission and distribution model of the National Energy Modeling System

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-02-01

    The Natural Gas Transmission and Distribution Model (NGTDM) is the component of the National Energy Modeling System (NEMS) that is used to represent the domestic natural gas transmission and distribution system. NEMS was developed in the Office of Integrated Analysis and Forecasting of the Energy Information Administration (EIA). NEMS is the third in a series of computer-based, midterm energy modeling systems used since 1974 by the EIA and its predecessor, the Federal Energy Administration, to analyze domestic energy-economy markets and develop projections. From 1982 through 1993, the Intermediate Future Forecasting System (IFFS) was used by the EIA for its analyses, and the Gas Analysis Modeling System (GAMS) was used within IFFS to represent natural gas markets. Prior to 1982, the Midterm Energy Forecasting System (MEFS), also referred to as the Project Independence Evaluation System (PIES), was employed. NEMS was developed to enhance and update EIA`s modeling capability by internally incorporating models of energy markets that had previously been analyzed off-line. In addition, greater structural detail in NEMS permits the analysis of a broader range of energy issues. The time horizon of NEMS is the midterm period (i.e., through 2015). In order to represent the regional differences in energy markets, the component models of NEMS function at regional levels appropriate for the markets represented, with subsequent aggregation/disaggregation to the Census Division level for reporting purposes.

  2. Data transmission

    National Research Council Canada - National Science Library

    Tugal, Dogan A; Tugal, Osman

    1989-01-01

    This updated second edition provides working answers to today's critical questions about designing and managing all types of data transmission systems and features a new chapter on local area networks (LANs...

  3. ELECTRODYNAMICS OF TRANSMISSION AND LOSSES OF POWER IN THE DEVICES OF ELECTRIC TRACTION SYSTEMS

    Directory of Open Access Journals (Sweden)

    M. O. Kostin

    2014-01-01

    Full Text Available Purpose. Theoretical justification of the "field" approach (based on electromagnetic field to the transmission and losses of power in the devices of traction power supply systems and electric rolling stock. Methodology. The methods of electromagnetic field theory and, in particular, the theory and practice of electromagnetic energy transmission based on the concept of the Poynting vector and elements of the theory of propagation, reflection and refraction of plane electromagnetic waves were used. Findings. Theoretical studies of electromagnetic energy transmission from the traction substation to the electric rolling stock through dielectric (air surrounding traction network: between the contact wire and the rail were carried out. It is proposed strategic designing "squat" (low types of electric rolling stock. The components of electric energy flow through the roof of electric rolling stock and its frontal part of the body were estimated. This allows reliable etimating active power losses in electric traction system. To compensate the reactive power consumed by electric rolling stock, which is conditioned by standing waves, it is proposed (for extinction of the the last to develop and put in front of electric rolling stock the layer of particular environment with the necessary parameters. Originality. The "field" principle of the power transmission analysis and its losses arising in electric traction system was first proposed. The laws of motion of electromagnetic energy flows through the roof and the frontal part of the body of electric rolling stock were established. Practical value. An expression of the absolute value of the Poynting vector in the points of dielectric (air between the contact wire and the rail was obtained. This allows assessing the highest density of energy, which is transferred to the time unit and predicting the main dimensions of the unit of electric rolling stock. The energy indices of the roof of electric rolling stock

  4. Relationship between child survival and malaria transmission: an analysis of the malaria transmission intensity and mortality burden across Africa (MTIMBA) project data in Rufiji demographic surveillance system, Tanzania.

    Science.gov (United States)

    Rumisha, Susan F; Smith, Thomas A; Masanja, Honorati; Abdulla, Salim; Vounatsou, Penelope

    2014-03-28

    The precise nature of the relationship between malaria mortality and levels of transmission is unclear. Due to methodological limitations, earlier efforts to assess the linkage have lead to inconclusive results. The malaria transmission intensity and mortality burden across Africa (MTIMBA) project initiated by the INDEPTH Network collected longitudinally entomological data within a number of sites in sub-Saharan Africa to study this relationship. This work linked the MTIMBA entomology database with the routinely collected vital events within the Rufiji Demographic Surveillance System to analyse the transmission-mortality relation in the region. Bayesian Bernoulli spatio-temporal Cox proportional hazards models with village clustering, adjusted for age and insecticide-treated nets (ITNs), were fitted to assess the relation between mortality and malaria transmission measured by entomology inoculation rate (EIR). EIR was predicted at household locations using transmission models and it was incorporated in the model as a covariate with measure of uncertainty. Effects of covariates estimated by the model are reported as hazard ratios (HR) with 95% Bayesian confidence interval (BCI) and spatial and temporal parameters are presented. Separate analysis was carried out for neonates, infants and children 1-4 years of age. No significant relation between all-cause mortality and intensity of malaria transmission was indicated at any age in childhood. However, a strong age effect was shown. Comparing effects of ITN and EIR on mortality at different age categories, a decrease in protective efficacy of ITN was observed (i.e. neonates: HR = 0.65; 95% BCI:0.39-1.05; infants: HR = 0.72; 95% BCI:0.48-1.07; children 1-4 years: HR = 0.88; 95% BCI:0.62-1.23) and reduction on the effect of malaria transmission exposure was detected (i.e. neonates: HR = 1.15; 95% BCI:0.95-1.36; infants: HR = 1.13; 95% BCI:0.98-1.25; children 1-4 years: HR = 1.04; 95% BCI:0.89-1.18). A very strong spatial

  5. Higher-order aberration corrector for an image-forming system in a transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Sawada, H., E-mail: hsawada@jeol.co.jp [CREST, Japan Science and Technology Agency, 5 Sanbancho, Chiyoda-ku, Tokyo 102-0075 (Japan); JEOL Ltd., 3-1-2 Musashino, Akishima, Tokyo (Japan); Sasaki, T. [CREST, Japan Science and Technology Agency, 5 Sanbancho, Chiyoda-ku, Tokyo 102-0075 (Japan); JEOL Ltd., 3-1-2 Musashino, Akishima, Tokyo (Japan); Hosokawa, F.; Yuasa, S.; Terao, M.; Kawazoe, M.; Nakamichi, T. [JEOL Ltd., 3-1-2 Musashino, Akishima, Tokyo (Japan); Kaneyama, T. [CREST, Japan Science and Technology Agency, 5 Sanbancho, Chiyoda-ku, Tokyo 102-0075 (Japan); JEOL Ltd., 3-1-2 Musashino, Akishima, Tokyo (Japan); Kondo, Y. [CREST, Japan Science and Technology Agency, 5 Sanbancho, Chiyoda-ku, Tokyo 102-0075 (Japan); Kimoto, K. [CREST, Japan Science and Technology Agency, 5 Sanbancho, Chiyoda-ku, Tokyo 102-0075 (Japan); National Institute for Materials Science, 1-1 Namiki, Tsukuba, Ibaraki 305-0044 (Japan); Suenaga, K. [CREST, Japan Science and Technology Agency, 5 Sanbancho, Chiyoda-ku, Tokyo 102-0075 (Japan); Research Center for Advanced Carbon Materials, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba 305-8565 (Japan)

    2010-07-15

    We developed a new electron optical system with three dodecapoles to compensate for spherical aberration and six-fold astigmatism, which generally remains in a two-hexapole type corrector. In this study, we applied the corrector for image-forming system in transmission electron microscope. Compensation for higher-order aberration was demonstrated through a diffractogram tableau using a triple three-fold astigmatism field system, which was then compared with a double hexapole field system. Using this electron optical system, six-fold astigmatism was measured to be less than 0.1 mm at an acceleration voltage of 60 kV, showing that the system successfully compensated for six-fold astigmatism.

  6. Analysis of operations and cyber security policies for a system of cooperating Flexible Alternating Current Transmission System (FACTS) devices.

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, Laurence R.; Tejani, Bankim; Margulies, Jonathan; Hills, Jason L.; Richardson, Bryan T.; Baca, Micheal J.; Weiland, Laura

    2005-12-01

    Flexible Alternating Current Transmission Systems (FACTS) devices are installed on electric power transmission lines to stabilize and regulate power flow. Power lines protected by FACTS devices can increase power flow and better respond to contingencies. The University of Missouri Rolla (UMR) is currently working on a multi-year project to examine the potential use of multiple FACTS devices distributed over a large power system region in a cooperative arrangement in which the FACTS devices work together to optimize and stabilize the regional power system. The report describes operational and security challenges that need to be addressed to employ FACTS devices in this way and recommends references, processes, technologies, and policies to address these challenges.

  7. Stability analysis of transmission system with high penetration of distributed generation

    Energy Technology Data Exchange (ETDEWEB)

    Reza, M.

    2006-12-21

    Nowadays, interest in generating electricity using decentralized generators of relatively small scale ('distributed generation', DG) is increasing. This work deals with the impact of implementing DG on the transmission system transient stability, with the emphasis on a potential transition from a 'vertical power system' to a 'horizontal power system. A problem in power systems is maintaining synchronous operation of all (centralized) synchronous machines. This stability problem associated is called rotor angle stability. In this work, the impact of the DG implementation on this is investigated. The impact of DG levels on the system transient stability when the increasing DG level is followed by a reduction of centralized generators in service resulting in a 'vertical to horizontal' transformation of the power system is also investigated. Furthermore, a stochastic analysis is used to study the transient stability of the power systems. The results show that including the stochastic behavior of DG leads to a more complete and detailed view of the system performance. Finally, the situation when the power system is pushed towards a scenario, where DG penetration reaches a level that covers the total load of the original power system (100% DG level) is investigated. The research performed in this work indicates that from the transmission system stability point of view, if higher DG penetration levels are coming up, sufficient inertia and voltage support must be installed. Furthermore, one should be aware of the fact that the system behaves stochastically, especially with DG. To a certain extent regional balancing of power can be performed by local voltage control.

  8. Application of wireless power transmission systems in wireless capsule endoscopy: an overview.

    Science.gov (United States)

    Basar, Md Rubel; Ahmad, Mohd Yazed; Cho, Jongman; Ibrahim, Fatimah

    2014-06-19

    Wireless capsule endoscopy (WCE) is a promising technology for direct diagnosis of the entire small bowel to detect lethal diseases, including cancer and obscure gastrointestinal bleeding (OGIB). To improve the quality of diagnosis, some vital specifications of WCE such as image resolution, frame rate and working time need to be improved. Additionally, future multi-functioning robotic capsule endoscopy (RCE) units may utilize advanced features such as active system control over capsule motion, drug delivery systems, semi-surgical tools and biopsy. However, the inclusion of the above advanced features demands additional power that make conventional power source methods impractical. In this regards, wireless power transmission (WPT) system has received attention among researchers to overcome this problem. Systematic reviews on techniques of using WPT for WCE are limited, especially when involving the recent technological advancements. This paper aims to fill that gap by providing a systematic review with emphasis on the aspects related to the amount of transmitted power, the power transmission efficiency, the system stability and patient safety. It is noted that, thus far the development of WPT system for this WCE application is still in initial stage and there is room for improvements, especially involving system efficiency, stability, and the patient safety aspects.

  9. The effect of grounding system modeling on lightning-related studies of transmission lines

    Directory of Open Access Journals (Sweden)

    Reza Shariatinasab

    2017-12-01

    Full Text Available Un-accurate modeling of power system may cause to under or over-design the insulation, which in turn, leads to increase in the investment and/or maintenance cost of the network protection against lightning overvoltages. The grounding system is an effective parameter on the magnitude of the lightning overvoltages and insulation coordination of high voltage transmission lines (TLs. This paper presents a comprehensive evaluation of the effect of grounding electrode impedance on the estimation of overvoltages caused by lightning strokes, in which both the vertical and non-vertical strokes are considered. In the presented study, static and wide-band model of the tower-footing grounding system is adopted assuming the soil electrical parameters to be either constant or frequency dependent. Also, the effect of modeling type of grounding system is considered on the TLs’ reliability indices. The study was performed on a typical 400-kV transmission line which is modeled in EMTP-RV. From the simulation results, it is found that the outage rate of TLs is markedly affected by the model of the tower footing grounding system. This effect is more pronounced when the soil electrical parameters are frequency dependent. It is also concluded that, in addition to the lightning overvoltages, the unavailability of the TLs is significantly affected by wide-band model of grounding system, non-vertical lightning strokes and soil resistivity.

  10. Brain potentials predict learning, transmission and modification of an artificial symbolic system.

    Science.gov (United States)

    Lumaca, Massimo; Baggio, Giosuè

    2016-12-01

    It has recently been argued that symbolic systems evolve while they are being transmitted across generations of learners, gradually adapting to the relevant brain structures and processes. In the context of this hypothesis, little is known on whether individual differences in neural processing capacity account for aspects of 'variation' observed in symbolic behavior and symbolic systems. We addressed this issue in the domain of auditory processing. We conducted a combined behavioral and EEG study on 2 successive days. On day 1, participants listened to standard and deviant five-tone sequences: as in previous oddball studies, an mismatch negativity (MMN) was elicited by deviant tones. On day 2, participants learned an artificial signaling system from a trained confederate of the experimenters in a coordination game in which five-tone sequences were associated to affective meanings (emotion-laden pictures of human faces). In a subsequent game with identical structure, participants transmitted and occasionally changed the signaling system learned during the first game. The MMN latency from day 1 predicted learning, transmission and structural modification of signaling systems on day 2. Our study introduces neurophysiological methods into research on cultural transmission and evolution, and relates aspects of variation in symbolic systems to individual differences in neural information processing. © The Author (2016). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  11. Accurate distortion estimation and optimal bandwidth allocation for scalable H.264 video transmission over MIMO systems.

    Science.gov (United States)

    Jubran, Mohammad K; Bansal, Manu; Kondi, Lisimachos P; Grover, Rohan

    2009-01-01

    In this paper, we propose an optimal strategy for the transmission of scalable video over packet-based multiple-input multiple-output (MIMO) systems. The scalable extension of H.264/AVC that provides a combined temporal, quality and spatial scalability is used. For given channel conditions, we develop a method for the estimation of the distortion of the received video and propose different error concealment schemes. We show the accuracy of our distortion estimation algorithm in comparison with simulated wireless video transmission with packet errors. In the proposed MIMO system, we employ orthogonal space-time block codes (O-STBC) that guarantee independent transmission of different symbols within the block code. In the proposed constrained bandwidth allocation framework, we use the estimated end-to-end decoder distortion to optimally select the application layer parameters, i.e., quantization parameter (QP) and group of pictures (GOP) size, and physical layer parameters, i.e., rate-compatible turbo (RCPT) code rate and symbol constellation. Results show the substantial performance gain by using different symbol constellations across the scalable layers as compared to a fixed constellation.

  12. Natural Gas Transmission and Distribution Model of the National Energy Modeling System. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-01-01

    The Natural Gas Transmission and Distribution Model (NGTDM) is the component of the National Energy Modeling System (NEMS) that is used to represent the domestic natural gas transmission and distribution system. The NGTDM is the model within the NEMS that represents the transmission, distribution, and pricing of natural gas. The model also includes representations of the end-use demand for natural gas, the production of domestic natural gas, and the availability of natural gas traded on the international market based on information received from other NEMS models. The NGTDM determines the flow of natural gas in an aggregate, domestic pipeline network, connecting domestic and foreign supply regions with 12 demand regions. The purpose of this report is to provide a reference document for model analysts, users, and the public that defines the objectives of the model, describes its basic design, provides detail on the methodology employed, and describes the model inputs, outputs, and key assumptions. Subsequent chapters of this report provide: an overview of NGTDM; a description of the interface between the NEMS and NGTDM; an overview of the solution methodology of the NGTDM; the solution methodology for the Annual Flow Module; the solution methodology for the Distributor Tariff Module; the solution methodology for the Capacity Expansion Module; the solution methodology for the Pipeline Tariff Module; and a description of model assumptions, inputs, and outputs.

  13. Transmission Selection Schemes using Sum Rate Analysis in Distributed Antenna Systems

    CERN Document Server

    Kim, Heejin; Lee, Kyoung-Jae; Lee, Inkyu

    2011-01-01

    In this paper, we study single cell multi-user downlink distributed antenna systems (DAS) where the antenna ports are geographically separated in a cell. First, we derive an expression of the ergodic sum rate for DAS in the presence of pathloss. Then, we propose a transmission selection scheme based on the derived expressions to maximize the overall ergodic sum rate. Utilizing the knowledge of distance information from a user to each distributed antenna (DA) port, we consider the pairings of each DA port and its supporting user to optimize the system performance. Then, we compute the ergodic sum rate for various transmission mode candidates and adopt a transmission selection scheme which chooses the best mode maximizing the ergodic sum rate among the mode candidates. In our proposed scheme, the number of mode candidates are greatly reduced compared to that of the ideal mode selection. Through Monte Carlo simulations, we will show the accuracy of our derivation for the ergodic sum rate expression. Moreover, si...

  14. A Secondary Voltage Control Method for an AC/DC Coupled Transmission System Based on Model Predictive Control

    DEFF Research Database (Denmark)

    Xu, Fengda; Guo, Qinglai; Sun, Hongbin

    2015-01-01

    to keep the voltage of the pilot bus tracking its set point considering the DC system’s transmission schedule change. The approach is inspired by model predictive control (MPC) to compensate for predictable voltage change affected by DC side transmission power flow and the potential capacitor switching......For an AC/DC coupled transmission system, the change of transmission power on the DC lines will significantly influence the AC systems’ voltage. This paper describes a method to coordinated control the reactive power of power plants and shunt capacitors at DC converter stations nearby, in order...

  15. LogAmp electronics and Optical Transmission for the new SPS Beam Position Measurement System

    CERN Document Server

    Deplano, C; Gonzalez, J L; Savioz, J J

    2013-01-01

    A new front-end board is under development for the CERN SPS Multi ORbit Position System (MOPOS). Based on logarithmic amplifiers, it measures the beam position over a large dynamic range of beam intensities and resolves the multi-batch structure of the SPS beams. Analogue data are digitized at 10 MS/s, packed in frames by an FPGA and on every turn sent to the readout board, via a 2.4 Gb/s optical transmission link. A first prototype has been successfully tested with several SPS beams. This paper presents an overall description of the system and its capabilities highlighted by the first beam measurements.

  16. The European Legislation Applicable to Medium-Range Inductive Wireless Power Transmission Systems

    Directory of Open Access Journals (Sweden)

    Frédéric Broydé

    2014-01-01

    Full Text Available Medium-range inductive wireless power transmission systems allow a sufficient power transfer without requiring close proximity between a primary coil and a secondary coil. We briefly investigate the range of a typical system and its radiated emission, from the perspectives of electromagnetic compatibility (EMC and human exposure requirements. We then discuss the applicable legislation in the European Union, the main question being the applicability of the R&TTE or radio equipment directives. Our conclusion is that this applicability depends on multiple parameters, among which is the presence of a self-tuning capability or of a transmitter control based on telemetry.

  17. Prospective application of advanced series compensation to improve transmission system performance

    Energy Technology Data Exchange (ETDEWEB)

    Gama, C.A.; Scavassa, J.L.; Silva, W.M. da; Silva, J.M.M. da; Ponte, J.R. [ELETRONORTE, Brasilia, DF (Brazil)

    1994-12-31

    This paper describes the main aspects and results of the planning studies undertaken to evaluate the technical benefits of using Thyristor Controlled Series Compensation (TCSC), in a large 500 kV transmission system (Brazilian North-Northeast system). TCSC controllers design and simplified models for digital non-linear time domain simulations are discussed. The proposed controllers are tuned and used to support the comparative analysis between controlled and fixed series compensation. The relevant conclusions concerning this comparison are highlighted. (author) 2 refs., 14 figs., 3 tabs.

  18. Full characterization of modern transmission fibers for Raman amplified-based communication systems.

    Science.gov (United States)

    Jiang, Shifeng; Bristiel, Bruno; Jaouën, Yves; Gallion, Philippe; Pincemin, Erwan; Capouilliet, Sylvain

    2007-04-16

    Telecommunication carriers have to estimate the Raman parameters of the fibers installed on their optical transport networks in order to facilitate the design of the next generation of high bit-rate Raman amplified-based transmission systems. This paper reports a very complete characterization of the most popular modern transmission fibers in terms of Raman efficiency, noise figure and double Rayleigh backscattering crosstalk. Our experiment is based on an averaged power analysis, applied to a counter-pumped long-haul distributed fiber Raman amplifier. We evaluate as well at 40 Gb/s for these different fiber types the double Rayleigh backscattering impact in terms of Q-factor penalty for various Raman gains and RZ modulation formats with different duty cycles.

  19. Combined laser ultrasonics, and Raman scattering in diamond anvil cell system operating in the transmission configuration

    Science.gov (United States)

    Zinin, P. V.; Burgess, K.; Prakapenka, V.; Sharma, S. K.; Kutuza, I. B.; Chigarev, N.; Gusev, V.

    2017-10-01

    Recently it has been demonstrated that it is possible to detect both longitudinal and shear waves as well as measure their velocities for a non-transparent iron layer compressed in a diamond anvil cell (DAC) to pressures approaching 23 GPa by using laser ultrasonics (LU) technique. These experiments were conducted in the reflection configuration when point source and point receiver were located at the same side of the specimen. The purpose of the present study is to examine the generation and detection of the acoustical waves in the LU-DAC system operating in the transmission configuration. The experimental results obtained at 16.4 GPa presented in this article demonstrate that the LU-DAC technique can be applied for longitudinal wave velocity measurements in small specimens under high pressure in the transmission configuration.

  20. Transmission of multi-dimensional signals for next generation optical communication systems

    Science.gov (United States)

    Yi, Anlin; Yan, Lianshan; Pan, Yan; Jiang, Lin; Chen, Zhiyu; Pan, Wei; Luo, Bin

    2018-02-01

    Over the past several decades, the data-carrying capacity of a single optical fiber have been increased significantly by fully exploring and optimizing physical dimensions of the light. Generally there are five major candidates of dimensions, including time, wavelength, polarization, space and quadrature (phase and amplitude). Multi-dimension, utilizing more than two dimensions of the light simultaneously, is one of the essential characteristics of next generation optical communication systems. We review recent advances in transmission of multi-dimensional signals, and highlight innovative ways of exploring the polarization dimension to further increase the capacity or spectral efficiency of a single optical fiber, a so-called pseudo-polarization-division-multiplexing (PPDM) technique. Related demonstrations include non-orthogonal PDM, PPDM of three and four states (PPDM-3 and PPDM-4). Brief discussions on trends of multi-dimensional signal transmission technologies are also presented.