WorldWideScience

Sample records for hvdc transmission system

  1. Economic Aspect of HVDC Transmission System for Indonesia Consideration in Nuclear Power Development

    International Nuclear Information System (INIS)

    Edwaren Liun

    2009-01-01

    As a country with hundreds million people, Indonesia needs to generate large scale power and distribute it to thorough country to improve gross domestic product of the population. In the power transmission domain, the High Voltage Direct Current (HVDC) transmission system should be considered for the next decades concerning any technical and economical problems with HVAC transmission. HVDC transmission system is the answer for the Indonesian condition. This system can connect the high energy potential regions to the high energy demand regions. HVDC is the most efficient to transport energy from one region to another one region. Dismantling and removing assets costs are included to the estimated for capital costs, while the environmental and property costs are the costs of securing designations and resource consents, and valuation and legal advice for the HVDC investment. Although converter terminals are expensive however, for long transmissions HVDC system can compensate the costs over breakeven distance through very efficient transmission system. Efficiency of HVDC is appearing from conductor wire, supporting tower, low energy loses and free space used by route of the transmission line. HVDC system is also free from some problem, concerning stability, inductive and capacitive load components, phase differences and frequency system. In the economic aspect the HVDC capital costs for the transmission options comprise estimates of the cost to design, purchase and construct new HVDC transmission components. While operating and maintenance costs of HVDC assets comprise the costs for replacement the old existing overhead transmission lines, underground and submarine cables, and HVDC converter station components. (author)

  2. Performance analysis of a model-sized superconducting DC transmission system based VSC-HVDC transmission technologies using RTDS

    International Nuclear Information System (INIS)

    Dinh, Minh-Chau; Ju, Chang-Hyeon; Kim, Sung-Kyu; Kim, Jin-Geun; Park, Minwon; Yu, In-Keun

    2012-01-01

    The combination of a high temperature superconducting DC power cable and a voltage source converter based HVDC (VSC-HVDC) creates a new option for transmitting power with multiple collection and distribution points for long distance and bulk power transmissions. It offers some greater advantages compared with HVAC or conventional HVDC transmission systems, and it is well suited for the grid integration of renewable energy sources in existing distribution or transmission systems. For this reason, a superconducting DC transmission system based HVDC transmission technologies is planned to be set up in the Jeju power system, Korea. Before applying this system to a real power system on Jeju Island, system analysis should be performed through a real time test. In this paper, a model-sized superconducting VSC-HVDC system, which consists of a small model-sized VSC-HVDC connected to a 2 m YBCO HTS DC model cable, is implemented. The authors have performed the real-time simulation method that incorporates the model-sized superconducting VSC-HVDC system into the simulated Jeju power system using Real Time Digital Simulator (RTDS). The performance analysis of the superconducting VSC-HVDC systems has been verified by the proposed test platform and the results were discussed in detail.

  3. Performance analysis of a model-sized superconducting DC transmission system based VSC-HVDC transmission technologies using RTDS

    Energy Technology Data Exchange (ETDEWEB)

    Dinh, Minh-Chau, E-mail: thanchau7787@gmail.com [Changwon National University, 9 Sarim-Dong, Changwon 641-733 (Korea, Republic of); Ju, Chang-Hyeon; Kim, Sung-Kyu; Kim, Jin-Geun; Park, Minwon [Changwon National University, 9 Sarim-Dong, Changwon 641-733 (Korea, Republic of); Yu, In-Keun, E-mail: yuik@changwon.ac.kr [Changwon National University, 9 Sarim-Dong, Changwon 641-733 (Korea, Republic of)

    2012-08-15

    The combination of a high temperature superconducting DC power cable and a voltage source converter based HVDC (VSC-HVDC) creates a new option for transmitting power with multiple collection and distribution points for long distance and bulk power transmissions. It offers some greater advantages compared with HVAC or conventional HVDC transmission systems, and it is well suited for the grid integration of renewable energy sources in existing distribution or transmission systems. For this reason, a superconducting DC transmission system based HVDC transmission technologies is planned to be set up in the Jeju power system, Korea. Before applying this system to a real power system on Jeju Island, system analysis should be performed through a real time test. In this paper, a model-sized superconducting VSC-HVDC system, which consists of a small model-sized VSC-HVDC connected to a 2 m YBCO HTS DC model cable, is implemented. The authors have performed the real-time simulation method that incorporates the model-sized superconducting VSC-HVDC system into the simulated Jeju power system using Real Time Digital Simulator (RTDS). The performance analysis of the superconducting VSC-HVDC systems has been verified by the proposed test platform and the results were discussed in detail.

  4. HVDC transmission from nuclear power plant

    International Nuclear Information System (INIS)

    Yoshida, Yukio; Takenaka, Kiyoshi; Taniguchi, Haruto; Ueda, Kiyotaka

    1980-01-01

    HVDC transmission directly from a nuclear power plant is expected as one of the bulk power transmission systems from distant power generating area. Successively from the analysis of HVDC transmission from BWR-type nuclear power plant, this report discusses dynamic response characteristics of HVDC transmission (double poles, two circuits) from PWR type nuclear power plant due to dc-line faults (DC-1LG, 2LG) and ac-line faults (3LG) near inverter station. (author)

  5. Modeling and application of VSC-HVDC in the European transmission system

    International Nuclear Information System (INIS)

    L'Abatte, A.; Fulli, G.

    2010-01-01

    This paper investigated the potential technical, environmental, and economic impacts of voltage source converter (VSC) based high voltage direct current (HVDC) technologies on the European power system, with particular emphasis on enhancing the attainable transmission capacity in specific applications. To this end, an original steady-state model of the VSC-HVDC was presented and tested. A techno-economic analysis of the potential impact of VSC-HVDC on liberalized power systems in Europe was performed to determine the feasibility of such investment compared to building conventional high voltage alternating current (HVAC) transmission infrastructures. The land use and environmental impact of HVDC may be lower than HVAC technologies. VSC-HVDC offers several advantages over conventional HVDC, including flexibility and range of power control, compactness and modularity of converter stations, easier expandability for multi-terminal configurations, and greater environmental friendliness. The relative disadvantages of the VSC-HVDC include a greater expense and higher converter losses. When replacing existing HVAC lines, some targeted VSC-HVDC installations were shown to be technologically and economically feasible, particularly when installed on lines between regions with a high electricity price differential, although less profitable than building new HVAC lines. VSC-HVDC can be a more feasible option when socio-political and environmental restraints curtail the extension of the HVAC transmission system. 29 refs., 6 tabs., 4 figs.

  6. Development of a coordinated control system for BWR nuclear power plant and HVDC transmission system

    International Nuclear Information System (INIS)

    Ishikawa, M.; Hara, T.; Hirayama, K.; Sekiya, K.

    1986-01-01

    The combined use of dc and ac transmissions or so-called hybrid transmission was under study, employing both dc and ac systems to enable stable transmission of 10,000 MW of electric power generated by the BWR nuclear plant, scheduled to be built about 800 km away from the center of the load. It was thus necessary to develop a hybrid power transmission control system, the hybrid power transmission system consisting of a high voltage dc transmission system (HVDC) and an ultrahigh ac transmission system (UHVAC). It was also necessary to develop a control system for HVDC transmission which protects the BWR nuclear power plant from being influenced by any change in transmission mode that occurs as a result of faults on the UHVAC side when the entire power of the BWR plant is being sent by the HVDC transmission. This paper clarifies the requirements for the HVDC system control during hybrid transmission and also during dc transmission. The control method that satisfies these requirements was studied to develop a control algorithm

  7. HVDC power transmission technology assessment

    Energy Technology Data Exchange (ETDEWEB)

    Hauth, R.L.; Tatro, P.J.; Railing, B.D. [New England Power Service Co., Westborough, MA (United States); Johnson, B.K.; Stewart, J.R. [Power Technologies, Inc., Schenectady, NY (United States); Fink, J.L.

    1997-04-01

    The purpose of this study was to develop an assessment of the national utility system`s needs for electric transmission during the period 1995-2020 that could be met by future reduced-cost HVDC systems. The assessment was to include an economic evaluation of HVDC as a means for meeting those needs as well as a comparison with competing technologies such as ac transmission with and without Flexible AC Transmission System (FACTS) controllers. The role of force commutated dc converters was to be assumed where appropriate. The assessment begins by identifying the general needs for transmission in the U.S. in the context of a future deregulated power industry. The possible roles for direct current transmission are then postulated in terms of representative scenarios. A few of the scenarios are illustrated with the help of actual U.S. system examples. non-traditional applications as well as traditional applications such as long lines and asynchronous interconnections are discussed. The classical ``break-even distance`` concept for comparing HVDC and ac lines is used to assess the selected scenarios. The impact of reduced-cost converters is reflected in terms of the break-even distance. This report presents a comprehensive review of the functional benefits of HVDC transmission and updated cost data for both ac and dc system components. It also provides some provocative thoughts on how direct current transmission might be applied to better utilize and expand our nation`s increasingly stressed transmission assets.

  8. Control strategies for VSC-based HVDC transmission system

    DEFF Research Database (Denmark)

    Stan, Ana-Irina; Stroe, Daniel Ioan; Silva, Rodrigo Da

    2011-01-01

    Throughout this paper the modeling and control of the VSC-based HVDC systems are investigated and described. Two different control methods capable of controlling such systems are proposed. Both developed control strategies are implemented in the dq synchronous reference frame. In order to analyze...... the behavior of the developed VSC-based HVDC transmission system two study cases are carried out using MATLAB/Simulink. The results obtained from simulations show acceptable performances, of the proposed strategies, when changes in the reference parameters are considered. The active power flow between...

  9. HVDC transmission from isorated nuclear power plant

    International Nuclear Information System (INIS)

    Takenaka, Kiyoshi; Takasaki, Masahiro; Ichikawa, Tatemi; Hayashi, Toshiyuki

    1985-01-01

    HVDC transmission directly from nuclear power plant is considered as one of the patterns of long distance and large capacity transmission system. This reports considers two route HVDC transmission from PWR type nuclear power plant, and analyzes dynamic response characteristics due to bus fault, main protection failure and etc. using the AC-DC Power System Simulator. (author)

  10. Dynamic simulation of hvdc transmission systems on digital computers

    Energy Technology Data Exchange (ETDEWEB)

    Hingorani, N G; Hay, J L; Crosbie, R E

    1966-05-01

    A digital computer technique is based on the fact that the operation of an hvdc converter consists of similar consecutive processes, each process having features which are common to all processes. Each bridge converter of an hvdc system is represented by a central process, and repetitive use of the latter simulates continuous converter operation. This technique may be employed to obtain the waveforms of transient or steady state voltages and currents anywhere in the dc system. To illustrate the method, an hvdc link is considered; the link which connects two independent ac systems conprises two converters with their control systems, and a dc transmission line. As an example, the transient behavior of the system is examined following changes in the current settings of the control system.

  11. Reprint of “Performance analysis of a model-sized superconducting DC transmission system based VSC-HVDC transmission technologies using RTDS”

    International Nuclear Information System (INIS)

    Dinh, Minh-Chau; Ju, Chang-Hyeon; Kim, Sung-Kyu; Kim, Jin-Geun; Park, Minwon; Yu, In-Keun

    2013-01-01

    Highlights: ► A model-sized superconducting VSC-HVDC system was designed and fabricated. ► A real-time simulation using Real Time Digital Simulator has been performed. ► The AC loss characteristics of HTS DC power cable caused by harmonics were analyzed. ► The AC loss of the HTS DC power cable will be used as a parameter to design the cable cooling system. -- Abstract: The combination of a high temperature superconducting DC power cable and a voltage source converter based HVDC (VSC-HVDC) creates a new option for transmitting power with multiple collection and distribution points for long distance and bulk power transmissions. It offers some greater advantages compared with HVAC or conventional HVDC transmission systems, and it is well suited for the grid integration of renewable energy sources in existing distribution or transmission systems. For this reason, a superconducting DC transmission system based HVDC transmission technologies is planned to be set up in the Jeju power system, Korea. Before applying this system to a real power system on Jeju Island, system analysis should be performed through a real time test. In this paper, a model-sized superconducting VSC-HVDC system, which consists of a small model-sized VSC-HVDC connected to a 2 m YBCO HTS DC model cable, is implemented. The authors have performed the real-time simulation method that incorporates the model-sized superconducting VSC-HVDC system into the simulated Jeju power system using Real Time Digital Simulator (RTDS). The performance analysis of the superconducting VSC-HVDC systems has been verified by the proposed test platform and the results were discussed in detail

  12. Reprint of “Performance analysis of a model-sized superconducting DC transmission system based VSC-HVDC transmission technologies using RTDS”

    Energy Technology Data Exchange (ETDEWEB)

    Dinh, Minh-Chau, E-mail: thanchau7787@gmail.com [Changwon National University, 9 Sarim-Dong, Changwon 641-733 (Korea, Republic of); Ju, Chang-Hyeon; Kim, Sung-Kyu; Kim, Jin-Geun; Park, Minwon [Changwon National University, 9 Sarim-Dong, Changwon 641-733 (Korea, Republic of); Yu, In-Keun, E-mail: yuik@changwon.ac.kr [Changwon National University, 9 Sarim-Dong, Changwon 641-733 (Korea, Republic of)

    2013-01-15

    Highlights: ► A model-sized superconducting VSC-HVDC system was designed and fabricated. ► A real-time simulation using Real Time Digital Simulator has been performed. ► The AC loss characteristics of HTS DC power cable caused by harmonics were analyzed. ► The AC loss of the HTS DC power cable will be used as a parameter to design the cable cooling system. -- Abstract: The combination of a high temperature superconducting DC power cable and a voltage source converter based HVDC (VSC-HVDC) creates a new option for transmitting power with multiple collection and distribution points for long distance and bulk power transmissions. It offers some greater advantages compared with HVAC or conventional HVDC transmission systems, and it is well suited for the grid integration of renewable energy sources in existing distribution or transmission systems. For this reason, a superconducting DC transmission system based HVDC transmission technologies is planned to be set up in the Jeju power system, Korea. Before applying this system to a real power system on Jeju Island, system analysis should be performed through a real time test. In this paper, a model-sized superconducting VSC-HVDC system, which consists of a small model-sized VSC-HVDC connected to a 2 m YBCO HTS DC model cable, is implemented. The authors have performed the real-time simulation method that incorporates the model-sized superconducting VSC-HVDC system into the simulated Jeju power system using Real Time Digital Simulator (RTDS). The performance analysis of the superconducting VSC-HVDC systems has been verified by the proposed test platform and the results were discussed in detail.

  13. Design, control and application of modular multilevel converters for HVDC transmission systems

    CERN Document Server

    Sharifabadi, Kamran; Nee, Hans-Peter; Norrga, Staffan; Teodorescu, Remus

    2016-01-01

    Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems is a comprehensive guide to semiconductor technologies applicable for MMC design, component sizing control, modulation, and application of the MMC technology for HVDC transmission. Separated into three distinct parts, the first offers an overview of MMC technology, including information on converter component sizing, Control and Communication, Protection and Fault Management, and Generic Modelling and Simulation. The second covers the applications of MMC in offshore WPP, including planning, technical and economic requirements and optimization options, fault management, dynamic and transient stability. Finally, the third chapter explores the applications of MMC in HVDC transmission and Multi Terminal configurations, including Supergrids.

  14. An Initial Topology of Multi-terminal HVDC Transmission System in Europe

    DEFF Research Database (Denmark)

    Irnawan, Roni; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2016-01-01

    In this paper, technical challenges for realizing offshore multi-terminal HVDC (MTDC) transmission system in Europe is evaluated. An offshore MTDC topology is projected by interconnecting point-to-point HVDC links with the same voltage level and technology found in south-eastern part of North Sea....... Availability analysis is done to evaluate the feasibility of the proposed offshore MTDC topology. As compared to point-to-point (PtP) HVDC link, MTDC operation gives a more secure and reliable system. This paper shows that the proposed MTDC topology can operate 98.36% of the time....

  15. HVDC transmission from nuclear power plant

    International Nuclear Information System (INIS)

    Yoshida, Yukio; Takenaka, Kiyoshi; Ichikawa, Takemi; Ueda, Kiyotaka; Machida, Takehiko

    1979-01-01

    The HVDC transmission directly from nuclear power plants is one of the patterns of long distance and large capacity HVDC transmission systems. In this report, the double pole, two-circuit HVDC transmission from a BWR nuclear power plant is considered, and the dynamic response characteristics due to the faults in dc line and ac line of inverter side are analyzed, to clarify the dynamic characteristics of the BWR nuclear power plant and dc system due to system faults and the effects of dc power control to prevent reactor scram. (1) In the instantaneous earthing fault of one dc line, the reactor is not scrammed by start-up within 0.8 sec. (2) When the earthing fault continues, power transmission drops to 75% by suspending the faulty pole, and the reactor is scrammed. (3) In the instantaneous ground fault of 2 dc lines, the reactor is not scrammed if the faulty dc lines are started up within 0.4 sec. (4) In the existing control of dc lines, the reactor is scrammed when the ac voltage at an ac-dc connection point largely drops due to ac failure. (J.P.N.)

  16. A novel power control strategy of Modular Multi-level Converter in HVDC-AC hybrid transmission systems for passive networks

    DEFF Research Database (Denmark)

    Hu, Zhenda; Wu, Rui; Yang, Xiaodong

    2014-01-01

    With the development of High Voltage DC Transmission (HVDC) technology, there will be more and more HVDC-AC hybrid transmission system in the world. A basic challenge in HVDC-AC hybrid transmission systems is to optimize the power sharing between DC and AC lines, which become more severe when sup...... control strategy of Modular Multi-level Converter in VSC-HVDC, which can optimize converter output power according to passive network loading variation. Proposal method is studied with a case study of a VSC-HVDC AC hybrid project by PSCAD/EMTDC simulations....

  17. Modular VSC converter based HVDC power transmission from offshore wind power plant: Compared to the conventional HVAC system

    DEFF Research Database (Denmark)

    Sharma, Ranjan; Rasmussen, Tonny Wederberg; Jensen, Kim Høj

    2010-01-01

    power transmission options with HVDC systems are under consideration. In this paper, a comparison between a conventional HVAC transmission system and a HVDC system equipped with modular voltage source converters is provided. The comparison is based on the total energy transmission capability...

  18. Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems

    DEFF Research Database (Denmark)

    Sharifabadi, Kamran; Harnefors, Lennart; Nee, Hans-Peter

    distinct parts, the first offers an overview of MMC technology, including information on converter component sizing, Control and Communication, Protection and Fault Management, and Generic Modelling and Simulation. The second covers the applications of MMC in offshore WPP, including planning, technical......Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems is a comprehensive guide to semiconductor technologies applicable for MMC design, component sizing control, modulation, and application of the MMC technology for HVDC transmission. Separated into three...

  19. Investigation of multimodule buck–boost inverter-based HVDC transmission system

    Directory of Open Access Journals (Sweden)

    Ahmed A. Elserougi

    2015-01-01

    Full Text Available In high voltage direct current (HVDC systems, the semiconductor devices have to be connected in series to obtain the required high-voltage ratings. This study proposes a new HVDC configuration, namely, multimodule buck–boost inverter for HVDC transmission applications which avoids series connection of large number of semiconductor switches. In addition, it provides a blocking capability against DC side faults. The proposed configuration consists of several simple buck–boost converters which are assembled together to meet the requirements of high-voltage high-power applications. This paper studies the dynamic performance of the proposed system under different operating conditions, and the results were satisfactory. The main advantages of the proposed configuration are: (i pure sinusoidal output which minimises/eliminates the requirements for supplementary AC filters and offers an inherent suppression to the common mode voltages, (ii very low dv/dt stresses and (iii complete blocking capability of AC side contributions during DC side faults. This study discusses the system architecture, passive components selections, voltage and current ratings of its semiconductor devices and the required controllers. A comparison between the proposed configuration and other existing HVDC technologies is also presented in this study.

  20. Performance Analysis of a Voltage Source Converter (VSC based HVDC Transmission System under Faulted Conditions

    Directory of Open Access Journals (Sweden)

    Amiri RABIE

    2009-12-01

    Full Text Available Voltage Source Converter (VSC based HVDC transmission technology hasbeen selected as the basis for several recent projects due to its controllability,compact modular design, ease of system interface, and low environmentalimpact. This paper investigates the dynamic performance of a 200MW,±100kV VSC-HVDC transmission system under some faulted conditionsusing MATLAB/Simulink. Simulation results confirm the satisfactoryperformance of the proposed system under active and reactive powervariations and fault conditions.

  1. Coordinated frequency regulation by offshore wind farms and VSC-HVDC transmission

    DEFF Research Database (Denmark)

    Liu, Hongzhi; Chen, Zhe

    2014-01-01

    converter-based HVDC (VSC-HVDC) transmission system to participate in power system frequency regulation. The strategy explores the frequency support capability of offshore wind farms and VSC-HVDC. By implementing the proposed coordinated control, the VSCHVDC link is able to provide quick virtual inertial...... are presented to demonstrate the frequency regulation capability of VSC-HVDC and validate the effectiveness of the proposed coordinated control strategy....

  2. Topologies of multiterminal HVDC-VSC transmission for large offshore wind farms

    Energy Technology Data Exchange (ETDEWEB)

    Gomis-Bellmunt, Oriol [Centre d' Innovacio Tecnologica en Convertidors Estatics i Accionaments (CITCEA-UPC), Universitat Politecnica de Catalunya UPC, Av. Diagonal, 647, Pl. 2. 08028 Barcelona (Spain); IREC Catalonia Institute for Energy Research, Barcelona (Spain); Liang, Jun; Ekanayake, Janaka; King, Rosemary; Jenkins, Nicholas [School of Engineering, Cardiff University, Queen' s Buildings, The Parade, Cardiff CF24 3AA, Wales (United Kingdom)

    2011-02-15

    Topologies of multiterminal HVDC-VSC transmission systems for large offshore wind farms are investigated. System requirements for multiterminal HVDC are described, particularly the maximum power loss allowed in the event of a fault. Alternative control schemes and HVDC circuit topologies are reviewed, including the need for HVDC circuit breakers. Various topologies are analyzed and compared according to a number of criteria: number and capacity of HVDC circuits, number of HVDC circuit breakers, maximum power loss, flexibility, redundancy, lines utilization, need for offshore switching platforms and fast communications. (author)

  3. The limits of HVDC transmission

    International Nuclear Information System (INIS)

    Pickard, William F.

    2013-01-01

    Renewable energy is abundant, but not necessarily near the urban centers where it will be used. Therefore, it must be transported; and this transport entails a systemic energy penalty. In this paper simple qualitative calculations are introduced to show (i) that high-voltage direct-current (HVDC) power lines for megameter and greater distances are unlikely to achieve power capacities much beyond 2 GW, although they can be paralleled; (ii) that most sources and sinks of electric power are rather less than 10,000 km apart; (iii) that such long lines can be constructed to have transmission losses -tilde 2%; and (iv) that lines of such low loss in fact meet minimal standards of intergenerational equity. - Highlights: • Renewable Energy is abundant, but not necessarily near population centers. • Its transportation requires energy and can be a major systemic inefficiency. • HVDC can be transmitted 10,000 km with 2% loss and near-optimal embodied energy. • Such transmission meets the requirements of intergenerational equity

  4. The role of facts and HVDC in the future pan-European transmission system development

    NARCIS (Netherlands)

    L'Abbate, A.; Migliavacca, G.; Hager, U.; Rehtanz, C.; Ruberg, S.; Lopes Ferreira, H.M.; Fulli, G.; Purvins, A.

    2010-01-01

    The present paper focuses on FACTS (Flexible Alternating Current Transmission System) and HVDC (High Voltage Direct Current) transmission technologies. Particular attention is paid to different specific technical, economic and environmental features of these power electronics-based devices. Final

  5. A novel synthetic test system for thyristor level in the converter valve of HVDC power transmission

    Directory of Open Access Journals (Sweden)

    Liu Longchen

    2016-01-01

    Full Text Available The converter valve is the core equipment in the HVDC power transmission system, a+-nd its performance has a direct effect on the reliability, stability and efficiency of the whole power system. As the basic unit of HVDC converter valve, the thyristor level needs to be test routinely in order to grasp the state of the converter valve equipment. Therefore, it is urgent to develop a novel synthetic test system for the thyristor level with thyristor control unit (TCU. However, currently there is no specific test scheme for the thyristor level of HVDC converter valve. In this paper, the synthetic test principle, content and methods for the thyristor level with TCU are presented based on the analysis of the thyristor reverse recovery characteristic and the IEC technology standard. And a transient high-voltage pulse is applied to the thyristor level during its reverse recovery period in order to test the characteristics of thyristor level. Then, the synthetic test system for the thyristor level is applied to the converter valve test of ±800 kV HVDC power transmission project, and the practical test result verifies the reasonability and validity of the proposed synthetic test system.

  6. Cost estimation of HVDC transmission system of Bangka's NPP candidates

    Science.gov (United States)

    Liun, Edwaren; Suparman

    2014-09-01

    Regarding nuclear power plant development in Bangka Island, it can be estimated that produced power will be oversupply for the Bangka Island and needs to transmit to Sumatra or Java Island. The distance between the regions or islands causing considerable loss of power in transmission by alternating current, and a wide range of technical and economical issues. The objective of this paper addresses to economics analysis of direct current transmission system to overcome those technical problem. Direct current transmission has a stable characteristic, so that the power delivery from Bangka to Sumatra or Java in a large scale efficiently and reliably can be done. HVDC system costs depend on the power capacity applied to the system and length of the transmission line in addition to other variables that may be different.

  7. DC Grid Control Concept for Expandable Multi-terminal HVDC Transmission Systems

    DEFF Research Database (Denmark)

    Irnawan, Roni; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2018-01-01

    In areas where there are already several HVDC links in operation or under construction, it is more likely that a DC grid emerges as a gradual process. Although the DC grid control concept has been widely discussed, the implementation in the expandable multi-terminal HVDC (MTDC) transmission systems...... still faces challenges. The existing converter control system needs to be adjusted when a point-to-point (PtP) link is operated into MTDC system, or when an additional converter is interconnected with an existing MTDC system, or even when a new DC grid control strategy is applied. In this paper, a new...... DC grid control concept is proposed that conserves and uses the existing converter control when an existing PtP link is extended into MTDC system or the existing MTDC system is expanded. An interface is proposed to decouple the DC grid secondary with converter control structures. By using...

  8. Fundamental study of bulk power HVDC transmission

    International Nuclear Information System (INIS)

    1981-01-01

    Study on the HVDC power transmission have been conducted since 1956. Shinshinano-Frequency Changer had been operated at first on 1977, as our home product, and Hokkaido-Honshu DC transmission also realized at 1979. Research and Development of the bulk power HVDC have been promoted by the UHV transmission special committee in our Institute from 1980. This paper is a comprehensive report published in the parts of operating control, insulation of DC line and countermeasure of fault current, and interferences in order to contribute for planning, design and operating of the UHV DC transmission in future. (author)

  9. Comparative study of superconducting fault current limiter both for LCC-HVDC and VSC-HVDC systems

    Science.gov (United States)

    Lee, Jong-Geon; Khan, Umer Amir; Lim, Sung-Woo; Shin, Woo-ju; Seo, In-Jin; Lee, Bang-Wook

    2015-11-01

    High Voltage Direct Current (HVDC) system has been evaluated as the optimum solution for the renewable energy transmission and long-distance power grid connections. In spite of the various advantages of HVDC system, it still has been regarded as an unreliable system compared to AC system due to its vulnerable characteristics on the power system fault. Furthermore, unlike AC system, optimum protection and switching device has not been fully developed yet. Therefore, in order to enhance the reliability of the HVDC systems mitigation of power system fault and reliable fault current limiting and switching devices should be developed. In this paper, in order to mitigate HVDC fault, both for Line Commutated Converter HVDC (LCC-HVDC) and Voltage Source Converter HVDC (VSC-HVDC) system, an application of resistive superconducting fault current limiter which has been known as optimum solution to cope with the power system fault was considered. Firstly, simulation models for two types of LCC-HVDC and VSC-HVDC system which has point to point connection model were developed. From the designed model, fault current characteristics of faulty condition were analyzed. Second, application of SFCL on each types of HVDC system and comparative study of modified fault current characteristics were analyzed. Consequently, it was deduced that an application of AC-SFCL on LCC-HVDC system with point to point connection was desirable solution to mitigate the fault current stresses and to prevent commutation failure in HVDC electric power system interconnected with AC grid.

  10. DC power flow control for radial offshore multi-terminal HVDC transmission system by considering steady-state DC voltage operation range

    DEFF Research Database (Denmark)

    Irnawan, Roni; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2017-01-01

    This paper deals with a radial offshore multi-terminal HVDC (MTDC) transmission system which is formed by interconnection several existing offshore wind farm (OWF) HVDC links with a shore-to-shore (StS) HVDC link. A challenge arises when deciding the steady-state DC voltage operating level...

  11. HVDC Transmission an Outlook and Significance for Pakistani Power Sector

    Science.gov (United States)

    Ahmad, Muhammad; Wang, Zhixin; Wang, Jinjian; Baloach, Mazhar H.; Longxin, Bao; Hua, Qing

    2018-04-01

    Recently a paradigm shift in the power sector is observed, i.e., countries across the globe have deviated their attention to distributed generation rather than conventional centralized bulk generation. Owing to the above narrative, distributed energy resources e.g., wind and PV have gained the adequate attention of governments and researchers courtesy to their eco-friendly nature. On the contrary, the increased infiltration of distributed generation to the power system has introduced many technical and economical glitches such as long-distance transmission, transmission lines efficiency, control capability and cost etc. To mitigate these complications, the utility of high voltage direct current (HVDC) transmission has emerged as a possible solution. In this context, this paper includes a brief discussion on the fundamentals HVDC and its significance in Pakistani power sector. Furthermore, the potential of distributed energy resources for Pakistan is also the subject matter of this paper, so that significance of HVDC transmission can effectively be deliberated.

  12. Power Flow Analysis of HVAC and HVDC Transmission Systems for Offshore WindParks

    DEFF Research Database (Denmark)

    da Silva, Filipe Miguel Faria; Castro, Rui

    2009-01-01

    As the onshore wind resource is running shorter, wind power promoters are paying attention to the offshore resources. As in most cases there is no load offshore, wind power must be transmitted to the main land. To do so, two options are available: HVAC and HVDC transmission systems. In this paper...... that HVAC solution is limited by the distance to shore and by the wind transmitted power. HVDC options do not show these limitations, but are more expensive and more delicate to deal with, because there is a lack of operational experience, so far....

  13. Comparative study of superconducting fault current limiter both for LCC-HVDC and VSC-HVDC systems

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong-Geon; Khan, Umer Amir; Lim, Sung-Woo; Shin, Woo-ju; Seo, In-Jin; Lee, Bang-Wook, E-mail: bangwook@hanyang.ac.kr

    2015-11-15

    Highlights: • The role of SFCL in types of HVDC system was evaluated. • A simulation model based on Korea Jeju–Haenam HVDC power system was designed in Matlab/Simulink. • Utilizing the designed both HVDC power system models, the efficiency of DC-SFCL was relatively low, compared to AC-SFCL. • It was deduced that the AC-SFCL was more effective in LCC-HVDC system than VSC-HVDC system. - Abstract: High Voltage Direct Current (HVDC) system has been evaluated as the optimum solution for the renewable energy transmission and long-distance power grid connections. In spite of the various advantages of HVDC system, it still has been regarded as an unreliable system compared to AC system due to its vulnerable characteristics on the power system fault. Furthermore, unlike AC system, optimum protection and switching device has not been fully developed yet. Therefore, in order to enhance the reliability of the HVDC systems mitigation of power system fault and reliable fault current limiting and switching devices should be developed. In this paper, in order to mitigate HVDC fault, both for Line Commutated Converter HVDC (LCC-HVDC) and Voltage Source Converter HVDC (VSC-HVDC) system, an application of resistive superconducting fault current limiter which has been known as optimum solution to cope with the power system fault was considered. Firstly, simulation models for two types of LCC-HVDC and VSC-HVDC system which has point to point connection model were developed. From the designed model, fault current characteristics of faulty condition were analyzed. Second, application of SFCL on each types of HVDC system and comparative study of modified fault current characteristics were analyzed. Consequently, it was deduced that an application of AC-SFCL on LCC-HVDC system with point to point connection was desirable solution to mitigate the fault current stresses and to prevent commutation failure in HVDC electric power system interconnected with AC grid.

  14. Comparative study of superconducting fault current limiter both for LCC-HVDC and VSC-HVDC systems

    International Nuclear Information System (INIS)

    Lee, Jong-Geon; Khan, Umer Amir; Lim, Sung-Woo; Shin, Woo-ju; Seo, In-Jin; Lee, Bang-Wook

    2015-01-01

    Highlights: • The role of SFCL in types of HVDC system was evaluated. • A simulation model based on Korea Jeju–Haenam HVDC power system was designed in Matlab/Simulink. • Utilizing the designed both HVDC power system models, the efficiency of DC-SFCL was relatively low, compared to AC-SFCL. • It was deduced that the AC-SFCL was more effective in LCC-HVDC system than VSC-HVDC system. - Abstract: High Voltage Direct Current (HVDC) system has been evaluated as the optimum solution for the renewable energy transmission and long-distance power grid connections. In spite of the various advantages of HVDC system, it still has been regarded as an unreliable system compared to AC system due to its vulnerable characteristics on the power system fault. Furthermore, unlike AC system, optimum protection and switching device has not been fully developed yet. Therefore, in order to enhance the reliability of the HVDC systems mitigation of power system fault and reliable fault current limiting and switching devices should be developed. In this paper, in order to mitigate HVDC fault, both for Line Commutated Converter HVDC (LCC-HVDC) and Voltage Source Converter HVDC (VSC-HVDC) system, an application of resistive superconducting fault current limiter which has been known as optimum solution to cope with the power system fault was considered. Firstly, simulation models for two types of LCC-HVDC and VSC-HVDC system which has point to point connection model were developed. From the designed model, fault current characteristics of faulty condition were analyzed. Second, application of SFCL on each types of HVDC system and comparative study of modified fault current characteristics were analyzed. Consequently, it was deduced that an application of AC-SFCL on LCC-HVDC system with point to point connection was desirable solution to mitigate the fault current stresses and to prevent commutation failure in HVDC electric power system interconnected with AC grid.

  15. Economic comparison of HVDC transmission and coal transport for Kalimantan - Sulawesi power system expansion

    International Nuclear Information System (INIS)

    Edwaren Liun

    2016-01-01

    Due to the load characteristics on many regions in Indonesia, the electrical system is often inefficient. In areas far from an interconnected network, for example isolated island, the choice of low cost fueled plants such as coal can not be applied, while the oil fueled has a very high generation cost and high burdened on subsidies. As a result, those area are still use oil fueled plant by limiting the generator flame time and consumers do not receive satisfactory service. This paper aims to analyze the extent to which the benefit of HVDC transmission system from Kalimantan to Sulawesi so that consumers could get better services and able to produce in order to improve their welfare. The method used in this analysis is a literature study and perform calculations based on existing formula. The result shows that in term of direct cost, HVDC system which covers transmission line, converter and loses cost, yield in a range of 0.46 - 0.60 USD¢/kWh for the capacity within 500 - 2000 Mwe. While coal transportation cost is in the range of 0.544 - 0.645 USD¢/kWh for long barge between 270 - 300 feet. Therefore, for the region of Indonesia which consist lots of islands and remote areas, power supply using HVDC transmission from area with more evolved electrical system could enable more economical, so that remote region also got excellent electrical services to improve the well-being and incomes of the population. (author)

  16. Cost estimation of HVDC transmission system of Bangka’s NPP candidates

    Energy Technology Data Exchange (ETDEWEB)

    Liun, Edwaren, E-mail: edwaren@batan.go.id; Suparman, E-mail: edwaren@batan.go.id [Centre for Nuclear Energy Development, National Nuclear Energy Agency of Indonesia (Indonesia)

    2014-09-30

    Regarding nuclear power plant development in Bangka Island, it can be estimated that produced power will be oversupply for the Bangka Island and needs to transmit to Sumatra or Java Island. The distance between the regions or islands causing considerable loss of power in transmission by alternating current, and a wide range of technical and economical issues. The objective of this paper addresses to economics analysis of direct current transmission system to overcome those technical problem. Direct current transmission has a stable characteristic, so that the power delivery from Bangka to Sumatra or Java in a large scale efficiently and reliably can be done. HVDC system costs depend on the power capacity applied to the system and length of the transmission line in addition to other variables that may be different.

  17. Cost estimation of HVDC transmission system of Bangka’s NPP candidates

    International Nuclear Information System (INIS)

    Liun, Edwaren; Suparman

    2014-01-01

    Regarding nuclear power plant development in Bangka Island, it can be estimated that produced power will be oversupply for the Bangka Island and needs to transmit to Sumatra or Java Island. The distance between the regions or islands causing considerable loss of power in transmission by alternating current, and a wide range of technical and economical issues. The objective of this paper addresses to economics analysis of direct current transmission system to overcome those technical problem. Direct current transmission has a stable characteristic, so that the power delivery from Bangka to Sumatra or Java in a large scale efficiently and reliably can be done. HVDC system costs depend on the power capacity applied to the system and length of the transmission line in addition to other variables that may be different

  18. Integration of wind power in Germany's transmission grid by using HVDC links

    Energy Technology Data Exchange (ETDEWEB)

    Wasserrab, Andreas; Fleckenstein, Marco; Balzer, Gerd [Technische Univ. Darmstadt (Germany). Inst. of Electrical Power and Energy

    2012-07-01

    This paper deals with the challenges for the integration of wind power in Germany's transmission grid. Several options for the expansion of transmission grids are discussed. The consideration focuses on HVDC technologies, which are used for further analyses. The basis of the analysis is the transmission grid of a German transmission system operator, which is implemented in a simulation tool. The model consists of the 110-kV-, 220-kV- and the 380-kV-system. In different scenarios the integration of wind power is analysed by applying HVDC links to connect the northern part of the grid with the load centres in the South. The results of load flow calculations are discussed focusing on transmission line loading and voltage stability. The paper concludes with future prospects of HVDC applications in Germany. (orig.)

  19. Interactions Between Indirect DC-Voltage Estimation and Circulating Current Controllers of MMC-Based HVDC Transmission Systems

    DEFF Research Database (Denmark)

    Wickramasinghe, Harith R.; Konstantinou, Georgios; Pou, Josep

    2018-01-01

    Estimation-based indirect dc-voltage control in MMCs interacts with circulating current control methods. This paper proposes an estimation-based indirect dc-voltage control method for MMC-HVDC systems and analyzes its performance compared to alternative estimations. The interactions between......-state and transient performance is demonstrated using a benchmark MMC-HVDC transmission system, implemented in a real-time digital simulator. The results verify the theoretical evaluations and illustrate the operation and performance of the proposed indirect dc-voltage control method....

  20. Separate Poles Mode for Large-Capacity HVDC System

    Science.gov (United States)

    Zhu, Lin; Gao, Qin

    2017-05-01

    This paper proposes a novel connection mode, separate poles mode (SPM), for large-capacity HVDC systems. The proposed mode focuses on the core issues of HVDC connection in interconnected power grids and principally aims at increasing effective electric distance between poles, which helps to mitigate the interaction problems between AC system and DC system. Receiving end of bipolar HVDC has been divided into different inverter stations under the mode, and thus significantly alleviates difficulties in power transmission and consumption of receiving-end AC grids. By investigating the changes of multi-feed short-circuit ratio (MISCR), finding that HVDC with SPM shows critical impacts upon itself and other HVDC systems with conventional connection mode, which demonstrates that SPM can make balance between MISCR increase and short-circuit current limit.

  1. Modelling and Simulation of SVPWM Based Vector Controlled HVDC Light Systems

    Directory of Open Access Journals (Sweden)

    Ajay Kumar MOODADLA

    2012-11-01

    Full Text Available Recent upgrades in power electronics technology have lead to the improvements of insulated gate bipolar transistor (IGBT based Voltage source converter High voltage direct current (VSC HVDC transmission systems. These are also commercially known as HVDC Light systems, which are popular in renewable, micro grid, and electric power systems. Out of different pulse width modulation (PWM schemes, Space vector PWM (SVPWM control scheme finds growing importance in power system applications because of its better dc bus utilization. In this paper, modelling of the converter is described, and SVPWM scheme is utilized to control the HVDC Light system in order to achieve better DC bus utilization, harmonic reduction, and for reduced power fluctuations. The simulations are carried out in the MATLAB/SIMULINK environment and the results are provided for steady state and dynamic conditions. Finally, the performance of SVPWM based vector controlled HVDC Light transmission system is compared with sinusoidal pulse width modulation (SPWM based HVDC Light system in terms of output voltage and total harmonic distortion (THD.

  2. HVDC-System-Interaction Assessment through Line-Flow Change-Distribution Factor and Transient-Stability Analysis at Planning Stage

    Directory of Open Access Journals (Sweden)

    Sungchul Hwang

    2016-12-01

    Full Text Available Many of the recent projects for new transmission line have considered the high-voltage direct current (HVDC system, owing to the many advantages of the direct current (DC system. The most noteworthy advantage is that a cable can serve as a substitute for the overhead transmission line in residential areas; therefore, the HVDC system application is increasing, and as the number of DC systems in the power system increases, the interaction assessment regarding the HVDC system gains importance. An index named multi-infeed interaction factor (MIIF is commonly used to estimate the interaction between power converters; however, the HVDC system is composed of two converters and a transmission line. The MIIF represents the interaction between the rectifiers and inverters, but not for the whole system. In this work, a method to assess the interaction of the whole system was therefore studied. To decide on the location of the new HVDC transmission system at the planning stage, in consideration of the interaction of the existing DC system, the line flow change distribution factor, according to the HVDC-transmission capacity change, was examined. Also, a power system transient -stability analysis was performed with different HVDC system locations, depending on the distribution factor. The simulation results indicate that when the factor is higher, two HVDC systems have a stronger interaction and are less stable in the transient state.

  3. Optimisation of VSC-HVDC Transmission for Wind Power Plants

    DEFF Research Database (Denmark)

    Silva, Rodrigo Da

    Connection of Wind Power Plants (WPP), typically oshore, using VSCHVDC transmission is an emerging solution with many benefits compared to the traditional AC solution, especially concerning the impact on control architecture of the wind farms and the grid. The VSC-HVDC solution is likely to meet...... more stringent grid codes than a conventional AC transmission connection. The purpose of this project is to analyse how HVDC solution, considering the voltage-source converter based technology, for grid connection of large wind power plants can be designed and optimised. By optimisation, the project...... the robust control technique is applied is compared with the classical proportional-integral (PI) performance, by means of time domain simulation in a point-to-point HVDC connection. The three main parameters in the discussion are the wind power delivered from the offshore wind power plant, the variation...

  4. New long-distance transmissions in Russia may use hvdc

    Energy Technology Data Exchange (ETDEWEB)

    1940-09-01

    Hvdc is considered for Kuibyshev-Moscow and other future Russian long-distance transmissions as a means to obtain higher transmission capacity and lower losses. A total saving of 46% is calculated as compared with ac transmission. An experimental transmission line will be built shortly.

  5. Fault ride-through and grid support of permanent magnet synchronous generator-based wind farms with HVAC and VSC-HVDC transmission systems

    DEFF Research Database (Denmark)

    Liu, Hongzhi; Chen, Zhe

    2012-01-01

    This paper describes fault ride-through and grid support of offshore wind farms based on permanent magnet synchronous generator (PMSG) wind turbines connected to the onshore AC network through two alternative transmission systems: high voltage AC (HVAC) or high voltage DC (HVDC) based on voltage...... source converters (VSC). The proposed configurations of the PMSG-based offshore wind farm and VSC-based HVDC are given as well as their control strategies under both steady state and fault state. The PMSG-based offshore wind farm is integrated into a test power transmission system via either HVAC or VSC...

  6. Offshore VSC-HVDC Networks : Impact on Transient Stability of AC Transmission Systems

    NARCIS (Netherlands)

    van der Meer, A.A.

    2017-01-01

    The transition towards a sustainable society calls for the massive deployment of renewable energy sources such as large wind parks located far offshore. High-voltage direct current transmission based on voltage sourced converter technology (VSC-HVDC) offers a wide range of technological benefits

  7. Modeling and power system stability of VSC-HVDC systems for grid-connection of large offshore windfarms

    Energy Technology Data Exchange (ETDEWEB)

    Xue Yijing [Vestas China, Beijing (China); Akhmatov, Vladislav [Technical Univ. of Denmark, Lyngby (Denmark). Centre for Electric Technology

    2009-07-01

    Utilization of Voltage Source Converter (VSC) - High Voltage Direct Current (HVDC) systems for grid-connection of large offshore windfarms becomes relevant as installed power capacities as well as distances to the connection points of on-land transmission systems increase. At the same time, the grid code requirements of the Transmission System Operators (TSO), including ancillary system services and Low-Voltage Fault-Ride-Through (LVFRT) capability of large offshore windfarms, become more demanding. This paper presents a general-level model of and a LVFRT solution for a VSC-HVDC system for grid-connection of large offshore windfarms. The VSC-HVDC model is implemented using a general approach of independent control of active and reactive power in normal operations. The on-land VSC inverter, i.e. a grid-side inverter, provides voltage support to the transmission system and comprises a LVFRT solution in short-circuit faults. The presented model, LVFRT solution and impact on the system stability are investigated as a case study of a 1,000 MW offshore windfarm grid-connected through a VSC-HVDC system. The investigation is carried out on a model of the west Danish, with some elements of the north German, 400 kV, 220 kV and 150 kV transmission systems stage 2005-2006 using the DIgSILENT PowerFactory simulation program. In the investigation, a thermal power plant just south to the Danish border has been substituted by this 1,000 MW offshore windfarm utilizing the VSC-HVDC system. The investigation has shown that the substitution of a thermal power plant by a VSC-HVDC connected offshore windfarm should not have any negative impact on the short-term stability of the west Danish transmission system. The investigation should be repeated applying updated system model stages and offshore wind power commissioning schedules in the North and Baltic Seas. (orig.)

  8. A method of Modelling and Simulating the Back-to-Back Modular Multilevel Converter HVDC Transmission System

    Science.gov (United States)

    Wang, Lei; Fan, Youping; Zhang, Dai; Ge, Mengxin; Zou, Xianbin; Li, Jingjiao

    2017-09-01

    This paper proposes a method to simulate a back-to-back modular multilevel converter (MMC) HVDC transmission system. In this paper we utilize an equivalent networks to simulate the dynamic power system. Moreover, to account for the performance of converter station, core components of model of the converter station gives a basic model of simulation. The proposed method is applied to an equivalent real power system.

  9. Suggested Methods for Preventing Core Saturation Instability in HVDC Transmission Systems

    Energy Technology Data Exchange (ETDEWEB)

    Norheim, Ian

    2002-07-01

    In this thesis a study of the HVDC related phenomenon core saturation instability and methods to prevent this phenomenon is performed. It is reason to believe that this phenomenon caused disconnection of the Skagerrak HVDC link 10 August 1993. Internationally, core saturation instability has been reported at several HVDC schemes and thorough complex studies of the phenomenon has been performed. This thesis gives a detailed description of the phenomenon and suggest some interesting methods to prevent the development of it. Core saturation instability and its consequences can be described in a simplified way as follows: It is now assumed that a fundamental harmonic component is present in the DC side current. Due to the coupling between the AC side and the DC side of the HVDC converter, a subsequent second harmonic positive-sequence current and DC currents will be generated on the AC side. The DC currents will cause saturation in the converter transformers. This will cause the magnetizing current to also have a second harmonic positive-sequence component. If a high second harmonic impedance is seen from the commutation bus, a high positive-sequence second harmonic component will be present in the commutation voltages. This will result in a relatively high fundamental frequency component in the DC side voltage. If the fundamental frequency impedance at the DC side is relatively low the fundamental component in the DC side current may become larger than it originally was. In addition the HVDC control system may contribute to the fundamental frequency component in the DC side voltage, and in this way cause a system even more sensitive to core saturation instability. The large magnetizing currents that eventually will flow on the AC side cause large zero-sequence currents in the neutral conductors of the AC transmission lines connected to the HVDC link. This may result in disconnection of the lines. Alternatively, the harmonics in the large magnetizing currents may cause

  10. Contribution of VSC-HVDC to Frequency Regulation of Power Systems With Offshore Wind Generation

    DEFF Research Database (Denmark)

    Liu, Hongzhi; Chen, Zhe

    2015-01-01

    to the onshore system grid through voltage-source converter-based–high voltage direct current (VSC-HVdc) transmission systems. Due to the decoupling of VSC-HVdc and signal transmission delay, offshore wind farms may not be able to respond to the onshore grid frequency excursion in time and, consequently......, the stability and security of the power system will be put at risk, especially for those with high wind penetration. This paper proposes a coordinated control scheme to allow VSC-HVdc link to contribute to the system frequency regulation by adjusting its dc-link voltage. By means of this approach, the dc...... capacitors of VSC-HVdc are controlled to absorb or release energy so as to provide frequency support. To further enhance the system frequency response, the frequency support from VSC-HVdc is also finely coordinated with that from offshore wind farm according to the latency of offshore wind farm responding...

  11. Stability analysis of multi-infeed HVDC system applying VSC-HVDC

    DEFF Research Database (Denmark)

    Liu, Yan; Chen, Zhe

    2010-01-01

    This paper presents a general model of dual infeed HVDC system applying VSC-HVDC, which can be used as an element in large multi infeed HVDC system. The model may have different structure under different grid faults because of the action of breakers. Hence power flow of the system based on this m...

  12. Development and Evaluation of cooperative control system for an HVDC transmission system connected with an isolated BWR power plant

    International Nuclear Information System (INIS)

    Horiuchi, Susumu; Hara, Tsukusi; Matori, Iwao; Hirayama, Kaiichirou.

    1987-01-01

    In the cooperative control system developed for an HVDC transmission system connected with an isolated BWR power plant, the equilibrium state between power plant output and DC transmission power is examined by way of the detection of the generator frequency. And, thereby start-up and shutdown of the DC system and controlling of the transmission power are made, so that the signal transmission with the power plant becomes unnecessary, enabling the easy cooperative operation. In order to investigate validity of this control system, various digital simulation and simulator test with the control system were carried out. In this way, behavior of the power plant and stability of the DC transmission system were evaluated in the connection to the DC system at power plant start-up, follow of the transmission power in change of the power plant output and in various system failures. (Mori, K.)

  13. Power control method on VSC-HVDC in a hybrid multi-infeed HVDC system

    DEFF Research Database (Denmark)

    Liu, Yan; Chen, Zhe

    2012-01-01

    Multi-infeed HVDC (MIDC) system connected with VSC-HVDC links and LCC-HVDC links is a new structure in modern power systems, which can be called hybrid multi-infeed HVDC (HMIDC) system. The paper presents the voltage stability analysis of a HMIDC system modeled from a possible future Danish power...

  14. Assessment on the influence of resistive superconducting fault current limiter in VSC-HVDC system

    Science.gov (United States)

    Lee, Jong-Geon; Khan, Umer Amir; Hwang, Jae-Sang; Seong, Jae-Kyu; Shin, Woo-Ju; Park, Byung-Bae; Lee, Bang-Wook

    2014-09-01

    Due to fewer risk of commutation failures, harmonic occurrences and reactive power consumptions, Voltage Source Converter (VSC) based HVDC system is known as the optimum solution of HVDC power system for the future power grid. However, the absence of suitable fault protection devices for HVDC system hinders the efficient VSC-HVDC power grid design. In order to enhance the reliability of the VSC-HVDC power grid against the fault current problems, the application of resistive Superconducting Fault Current Limiters (SFCLs) could be considered. Also, SFCLs could be applied to the VSC-HVDC system with integrated AC Power Systems in order to enhance the transient response and the robustness of the system. In this paper, in order to evaluate the role of SFCLs in VSC-HVDC systems and to determine the suitable position of SFCLs in VSC-HVDC power systems integrated with AC power System, a simulation model based on Korea Jeju-Haenam HVDC power system was designed in Matlab Simulink/SimPowerSystems. This designed model was composed of VSC-HVDC system connected with an AC microgrid. Utilizing the designed VSC-HVDC systems, the feasible locations of resistive SFCLs were evaluated when DC line-to-line, DC line-to-ground and three phase AC faults were occurred. Consequently, it was found that the simulation model was effective to evaluate the positive effects of resistive SFCLs for the effective suppression of fault currents in VSC-HVDC systems as well as in integrated AC Systems. Finally, the optimum locations of SFCLs in VSC-HVDC transmission systems were suggested based on the simulation results.

  15. Review of VSC HVDC Connection for Offshore Wind Power Integration

    DEFF Research Database (Denmark)

    Korompili, Asimenia; Wu, Qiuwei; Zhao, Haoran

    2016-01-01

    Voltage Source Converter (VSC) High Voltage Direct Current (HVDC) connection has become a new trend for long distance offshore wind power transmission. It has been confirmed by a lot of research that the maximum distance of a High Voltage Alternative Current (HVAC) sub-marine cable transmission...... system is limited due to surplus charging current of the cables. The VSC HVDC transmission system has the ability to overcome the limitation and offers other advantages over the HVAC transmission system. This paper is to review the VSC HVDC transmission technology and its application for offshore wind...

  16. The Study on Hybrid Multi-Infeed HVDC System Connecting with Offshore Wind Farm

    DEFF Research Database (Denmark)

    Liu, Yan

    furnish the VSC-HVDC connected wind farm with a fast and reliable LVRT ability. The voltage fluctuation caused by the intermittent wind power is another important challenge to the system stability. As in the case of the LCC-HVDC links, their stable operations are highly dependent on the AC side voltage...... with the short electrical distance. And consequently, a so-called Multi-Infeed Direct Current (MIDC) transmission system is formed. On the other hand, as the fast growing of wind power in electrical grids, the Voltage Source Converter based HVDC (VSC-HVDC) links have becoming a favorable choice for connecting...

  17. Simulative Study into the Development of a Hybrid HVDC System Through a Comparative Research with HVAC: a Futuristic Approach

    Directory of Open Access Journals (Sweden)

    R. S. Narayan

    2017-06-01

    Full Text Available High Voltage Direct Current Transmission (HVDC is considered a better solution for bulk long distance transmissions. The increased use of HVDC is a result of its advantages over the HVAC systems and especially of its fault stability nature. A better solution is proposed by using a Voltage Source Controlled–HVDC as one of the infeed for the Multi-Infeed HVDC (MIDC or MI-HVDC systems. The main advantage with the VSC converter is its flexible power control which enhances the stability of the MIDC systems. In this paper, the behavior of an HVDC system is compared with that of an HVAC during faults. A Hybrid HVDC system that includes a LCC as a rectifier unit and a VSC converter as the inverter is being proposed. It is considered suitable for MIDC systems and particularly for supplying a weak AC system. The performance of the system during steady state and transient conditions for all the proposed topologies including HVDC, HVAC and Hybrid HVDC are studied in MATLAB/SIMULINK. All of the proposed control strategies are evaluated via a series of simulation case studies.

  18. A Flexible Power Control Method of VSC-HVDC Link for the Enhancement of Effective Short-Circuit Ratio in a Hybrid Multi-Infeed HVDC System

    DEFF Research Database (Denmark)

    Liu, Yan; Chen, Zhe

    2013-01-01

    . To evaluate the contribution of the VSC-HVDC link on the voltage stability of HMIDC system, this paper proposes an effective short circuit ratio (ESCR) calculation method. Through the calculation, the voltage support capability of the VSC-HVDC link can be quantitatively represented by the ESCR. Furthermore......, based on the calculation results, a flexible power control strategy for the VSC-HVDC link is developed to provide maximum reactive power support under grid faults. The theoretical analysis of the HMIDC system is based on the Danish transmission grid, evaluated through PSCAD simulations under different...

  19. An adaptive neuro fuzzy inference system controlled space cector pulse width modulation based HVDC light transmission system under AC fault conditions

    Science.gov (United States)

    Ajay Kumar, M.; Srikanth, N. V.

    2014-03-01

    In HVDC Light transmission systems, converter control is one of the major fields of present day research works. In this paper, fuzzy logic controller is utilized for controlling both the converters of the space vector pulse width modulation (SVPWM) based HVDC Light transmission systems. Due to its complexity in the rule base formation, an intelligent controller known as adaptive neuro fuzzy inference system (ANFIS) controller is also introduced in this paper. The proposed ANFIS controller changes the PI gains automatically for different operating conditions. A hybrid learning method which combines and exploits the best features of both the back propagation algorithm and least square estimation method is used to train the 5-layer ANFIS controller. The performance of the proposed ANFIS controller is compared and validated with the fuzzy logic controller and also with the fixed gain conventional PI controller. The simulations are carried out in the MATLAB/SIMULINK environment. The results reveal that the proposed ANFIS controller is reducing power fluctuations at both the converters. It also improves the dynamic performance of the test power system effectively when tested for various ac fault conditions.

  20. A study of offshore wind HVDC system stability and control

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Hanchao; Sun, Jian [Rensselaer Polytechnic Institute, Troy, NY (United States). Dept. of Electrical, Computer and Systems Engineering

    2011-07-01

    This work is concerned with the stability and control of ac power collection buses in offshore wind farms with high-voltage dc (HVDC) transmission connection to onshore power grid. The focus of the work is high-frequency interactions among the wind turbines, the ac collection bus and the filters, as well as the HVDC rectifier. Both voltage-source converter and line-commutated converter based HVDC systems are considered. To study high-frequency stability, particularly harmonic resonance in the ac bus, small-signal impedance models are developed for the wind inverters and the HVDC rectifier by using harmonic linearization techniques. An impedance-based stability criterion is applied to assess system stability in both positive- and negative-sequence domain. Small-signal stability conditions and requirements are developed from analytical impedance models. Detailed system-level simulation is used to validated the small-signal analysis. The goal of the study is to develop system design and control techniques that minimize the cost of the offshore infrastructure while guaranteeing system stability and power quality. (orig.)

  1. A Droop Line Tracking Control for Multi-terminal VSC-HVDC Transmission System

    DEFF Research Database (Denmark)

    Irnawan, Roni; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2018-01-01

    Generally, a voltage-sourced converter (VSC) within a multi-terminal HVDC (MTDC) system can be operated either in constant DC voltage, constant flow (AC active power or DC current) or DC voltage droop control. These control modes can be easily represented as the droop characteristic line with dif......Generally, a voltage-sourced converter (VSC) within a multi-terminal HVDC (MTDC) system can be operated either in constant DC voltage, constant flow (AC active power or DC current) or DC voltage droop control. These control modes can be easily represented as the droop characteristic line...

  2. improvement of power system quality using vsc-based hvdc

    African Journals Online (AJOL)

    HOD

    Key words: HVDC, Voltage source converter (VSC), Current and Voltage Control Loop; FFT Analysis ... The main requirement in a power transmission system is .... drop over the reactor (. ) ..... Distribution Conference and Exhibition: Asia and.

  3. Short Circuit Ratio analysis of multi-infeed HVDC system with a VSC-HVDC link

    DEFF Research Database (Denmark)

    Liu, Yan; Chen, Zhe

    2011-01-01

    As an important indicator of system stability, Short Circuit Ratio (SCR) is commonly used in power system analysis. For systems include HVDC link connection, the Effective SCR (ESCR) is mostly applied to indicate the strength of HVDC infeed bus. The contribution of VSC-HVDC link to multi......-infeed HVDC system stability has been analyzed a lot but the study on ESCR of this kind of system is still insufficient. This paper presents a calculation method for ESCR of the hybrid multi infeed HVDC system based on a simple two-infeed HVDC system model. The equivalent circuit of this system under short...... circuit situation is firstly obtained based on the model. Then its Thevenin equivalent circuit is derived and system ESCR can be calculated. At last, simulation study verified that the calculated ESCR value under different cases can indicate the change of system stability....

  4. Assessment on the influence of resistive superconducting fault current limiter in VSC-HVDC system

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong-Geon; Khan, Umer Amir; Hwang, Jae-Sang; Seong, Jae-Kyu; Shin, Woo-Ju; Park, Byung-Bae; Lee, Bang-Wook, E-mail: bangwook@hanyang.ac.kr

    2014-09-15

    Highlights: • The role of SFCLs in VSC-HVDC systems was evaluated. • Simulation model based on Korea Jeju-Haenam HVDC power system was designed. • An effect and the feasible locations of resistive SFCLs were evaluated. • DC line-to-line, DC line-to-ground and 3 phase AC faults were imposed and analyzed. - Abstract: Due to fewer risk of commutation failures, harmonic occurrences and reactive power consumptions, Voltage Source Converter (VSC) based HVDC system is known as the optimum solution of HVDC power system for the future power grid. However, the absence of suitable fault protection devices for HVDC system hinders the efficient VSC-HVDC power grid design. In order to enhance the reliability of the VSC-HVDC power grid against the fault current problems, the application of resistive Superconducting Fault Current Limiters (SFCLs) could be considered. Also, SFCLs could be applied to the VSC-HVDC system with integrated AC Power Systems in order to enhance the transient response and the robustness of the system. In this paper, in order to evaluate the role of SFCLs in VSC-HVDC systems and to determine the suitable position of SFCLs in VSC-HVDC power systems integrated with AC power System, a simulation model based on Korea Jeju-Haenam HVDC power system was designed in Matlab Simulink/SimPowerSystems. This designed model was composed of VSC-HVDC system connected with an AC microgrid. Utilizing the designed VSC-HVDC systems, the feasible locations of resistive SFCLs were evaluated when DC line-to-line, DC line-to-ground and three phase AC faults were occurred. Consequently, it was found that the simulation model was effective to evaluate the positive effects of resistive SFCLs for the effective suppression of fault currents in VSC-HVDC systems as well as in integrated AC Systems. Finally, the optimum locations of SFCLs in VSC-HVDC transmission systems were suggested based on the simulation results.

  5. Assessment on the influence of resistive superconducting fault current limiter in VSC-HVDC system

    International Nuclear Information System (INIS)

    Lee, Jong-Geon; Khan, Umer Amir; Hwang, Jae-Sang; Seong, Jae-Kyu; Shin, Woo-Ju; Park, Byung-Bae; Lee, Bang-Wook

    2014-01-01

    Highlights: • The role of SFCLs in VSC-HVDC systems was evaluated. • Simulation model based on Korea Jeju-Haenam HVDC power system was designed. • An effect and the feasible locations of resistive SFCLs were evaluated. • DC line-to-line, DC line-to-ground and 3 phase AC faults were imposed and analyzed. - Abstract: Due to fewer risk of commutation failures, harmonic occurrences and reactive power consumptions, Voltage Source Converter (VSC) based HVDC system is known as the optimum solution of HVDC power system for the future power grid. However, the absence of suitable fault protection devices for HVDC system hinders the efficient VSC-HVDC power grid design. In order to enhance the reliability of the VSC-HVDC power grid against the fault current problems, the application of resistive Superconducting Fault Current Limiters (SFCLs) could be considered. Also, SFCLs could be applied to the VSC-HVDC system with integrated AC Power Systems in order to enhance the transient response and the robustness of the system. In this paper, in order to evaluate the role of SFCLs in VSC-HVDC systems and to determine the suitable position of SFCLs in VSC-HVDC power systems integrated with AC power System, a simulation model based on Korea Jeju-Haenam HVDC power system was designed in Matlab Simulink/SimPowerSystems. This designed model was composed of VSC-HVDC system connected with an AC microgrid. Utilizing the designed VSC-HVDC systems, the feasible locations of resistive SFCLs were evaluated when DC line-to-line, DC line-to-ground and three phase AC faults were occurred. Consequently, it was found that the simulation model was effective to evaluate the positive effects of resistive SFCLs for the effective suppression of fault currents in VSC-HVDC systems as well as in integrated AC Systems. Finally, the optimum locations of SFCLs in VSC-HVDC transmission systems were suggested based on the simulation results

  6. A Pilot Directional Protection for HVDC Transmission Line Based on Relative Entropy of Wavelet Energy

    Directory of Open Access Journals (Sweden)

    Sheng Lin

    2015-07-01

    Full Text Available On the basis of analyzing high-voltage direct current (HVDC transmission system and its fault superimposed circuit, the direction of the fault components of the voltage and the current measured at one end of transmission line is certified to be different for internal faults and external faults. As an estimate of the differences between two signals, relative entropy is an effective parameter for recognizing transient signals in HVDC transmission lines. In this paper, the relative entropy of wavelet energy is applied to distinguish internal fault from external fault. For internal faults, the directions of fault components of voltage and current are opposite at the two ends of the transmission line, indicating a huge difference of wavelet energy relative entropy; for external faults, the directions are identical, indicating a small difference. The simulation results based on PSCAD/EMTDC show that the proposed pilot protection system acts accurately for faults under different conditions, and its performance is not affected by fault type, fault location, fault resistance and noise.

  7. Advanced solutions in power systems HVDC, facts, and artificial intelligence

    CERN Document Server

    Liu, Chen-Ching; Edris, Abdel-Aty

    2016-01-01

    Provides insight on both classical means and new trends in the application of power electronic and artificial intelligence techniques in power system operation and control This book presents advanced solutions for power system controllability improvement, transmission capability enhancement and operation planning. The book is organized into three parts. The first part describes the CSC-HVDC and VSC-HVDC technologies, the second part presents the FACTS devices, and the third part refers to the artificial intelligence techniques. All technologies and tools approached in this book are essential for power system development to comply with the smart grid requirements.

  8. Passive AC network supplying the integration of CCC-HVDC and VSC-HVDC systems

    OpenAIRE

    BIDADFAR, Ali; ABEDI, Mehrdad; KARRARI, Mehdi

    2014-01-01

    The integration of a capacitor-commutated converter (CCC) high-voltage direct current (HVDC) (CCC-HVDC) and voltage source converter (VSC) HVDC (VSC-HVDC) is proposed in this paper to supply entirely passive AC networks. The key point of this integration is the flat characteristic of the DC voltage of the CCC-HVDC, which provides the condition for the VSC to connect to the CCC DC link via a current regulator. The advantages of the proposed combined infeeding system are the requirement o...

  9. Design of protective inductors for HVDC transmission line within DC grid offshore wind farms

    DEFF Research Database (Denmark)

    Deng, Fujin; Chen, Zhe

    2013-01-01

    in the HVDC link between the offshore station and the onshore station. The transient characteristics of the transmission system are analyzed in detail. The criteria of selecting protective inductors are proposed to effectively limit the short-circuit current and avoid the damage to the converters. A dc grid...

  10. DC Vs AC - War Of Currents For Future Power Systems A HVDC Technology Overview

    Directory of Open Access Journals (Sweden)

    Anil K. Rai

    2015-08-01

    Full Text Available DC vs AC discussion began in 1880s with development of first commercial power transmission in Wall Street New York. Later when AC technology came into notice by efforts of inventor and researcher Sir Nicola Tesla soon the advantages of AC transmission and AC devices overtook the DC technology. It was hoped that DC technology had lost battle of currents. Today with researches going on FACTS devices and bulk power transmission HVDC has again gained a reputation in power sector. Solution of this centuries old debate is to develop HVDC systems that assists HVAC systems for better performance stability and control

  11. Wind Farm Grid Integration Using VSC Based HVDC Transmission - An Overview

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay Kumar; Teodorescu, Remus; Rodriguez, Pedro

    2008-01-01

    The paper gives an overview of HVAC and HVDC connection of wind farm to the grid, with an emphasis on Voltage Source Converter (VSC)-based HVDC for large wind farms requiring long distance cable connection. Flexible control capabilities of a VSC-based HVDC system enables smooth integration of wind...... farm into the power grid network while meeting the Grid Code Requirements (GCR). Operation of a wind farm with VSC-based HVDC connection is described....

  12. Steady-state operational range evolution from a two-terminal to a multiterminal HVDC transmission system

    DEFF Research Database (Denmark)

    Irnawan, Roni; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2017-01-01

    DC grids are anticipated to grow organically with one possible initial configuration being formed by interconnecting an additional HVDC converter into an existing shore-to-shore (StS) HVDC link. In order to ensure the performance of this MTDC system, the DC voltage at each converter terminal within...

  13. Operational characteristics analysis of a 8 mH class HTS DC reactor for an LCC type HVDC system

    International Nuclear Information System (INIS)

    Kim, S. K.; Go, B. S.; Dinh, M. C.; Park, M.; Yu, I. K.; Kim, J. H.

    2015-01-01

    Many kinds of high temperature superconducting (HTS) devices are being developed due to its several advantages. In particular, the advantages of HTS devices are maximized under the DC condition. A line commutated converter (LCC) type high voltage direct current (HVDC) transmission system requires large capacity of DC reactors to protect the converters from faults. However, conventional DC reactor made of copper causes a lot of electrical losses. Thus, it is being attempted to apply the HTS DC reactor to an HVDC transmission system. The authors have developed a 8 mH class HTS DC reactor and a model-sized LCC type HVDC system. The HTS DC reactor was operated to analyze its operational characteristics in connection with the HVDC system. The voltage at both ends of the HTS DC reactor was measured to investigate the stability of the reactor. The voltages and currents at the AC and DC side of the system were measured to confirm the influence of the HTS DC reactor on the system. Two 5 mH copper DC reactors were connected to the HVDC system and investigated to compare the operational characteristics. In this paper, the operational characteristics of the HVDC system with the HTS DC reactor according to firing angle are described. The voltage and current characteristics of the system according to the types of DC reactors and harmonic characteristics are analyzed. Through the results, the applicability of an HTS DC reactor in an HVDC system is confirmed

  14. Operational characteristics analysis of a 8 mH class HTS DC reactor for an LCC type HVDC system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S. K.; Go, B. S.; Dinh, M. C.; Park, M.; Yu, I. K. [Changwon National University, Changwon (Korea, Republic of); Kim, J. H. [Daejeon University, Daejeon (Korea, Republic of)

    2015-03-15

    Many kinds of high temperature superconducting (HTS) devices are being developed due to its several advantages. In particular, the advantages of HTS devices are maximized under the DC condition. A line commutated converter (LCC) type high voltage direct current (HVDC) transmission system requires large capacity of DC reactors to protect the converters from faults. However, conventional DC reactor made of copper causes a lot of electrical losses. Thus, it is being attempted to apply the HTS DC reactor to an HVDC transmission system. The authors have developed a 8 mH class HTS DC reactor and a model-sized LCC type HVDC system. The HTS DC reactor was operated to analyze its operational characteristics in connection with the HVDC system. The voltage at both ends of the HTS DC reactor was measured to investigate the stability of the reactor. The voltages and currents at the AC and DC side of the system were measured to confirm the influence of the HTS DC reactor on the system. Two 5 mH copper DC reactors were connected to the HVDC system and investigated to compare the operational characteristics. In this paper, the operational characteristics of the HVDC system with the HTS DC reactor according to firing angle are described. The voltage and current characteristics of the system according to the types of DC reactors and harmonic characteristics are analyzed. Through the results, the applicability of an HTS DC reactor in an HVDC system is confirmed.

  15. Coordinated Control Strategies of VSC-HVDC-Based Wind Power Systems for Low Voltage Ride Through

    Directory of Open Access Journals (Sweden)

    Xinyin Zhang

    2015-07-01

    Full Text Available The Voltage Source Converter-HVDC (VSC-HVDC system applied to wind power generation can solve large scale wind farm grid-connection and long distance transmission problems. However, the low voltage ride through (LVRT of the VSC-HVDC connected wind farm is a key technology issue that must be solved, and it is currently lacking an economic and effective solution. In this paper, a LVRT coordinated control strategy is proposed for the VSC-HVDC-based wind power system. In this strategy, the operation and control of VSC-HVDC and wind farm during the grid fault period is improved. The VSC-HVDC system not only provides reactive power support to the grid, but also effectively maintains the power balance and DC voltage stability by reducing wind-farm power output, without increasing the equipment investment. Correspondingly, to eliminate the influence on permanent magnet synchronous generator (PMSG-based wind turbine (WT systems, a hierarchical control strategy is designed. The speed and validity of the proposed LVRT coordinated control strategy and hierarchical control strategy were verified by MATLAB/Simulink simulations.

  16. Coordinated Control Strategies for Offshore Wind Farm Integration via VSC-HVDC for System Frequency Support

    DEFF Research Database (Denmark)

    Li, Yujun; Xu, Zhao; Østergaard, Jacob

    2017-01-01

    Coordinated control strategies to provide system inertia support for main grid from offshore wind farm that is integrated through HVdc transmission is the subject matter of this paper. The strategy that seeks to provide inertia support to the main grid through simultaneous utilization of HVdc...... capacitors energy, and wind turbines (WTs) inertia without installing the remote communication of two HVdc terminals is introduced in details. Consequently, a novel strategy is proposed to improve system inertia through sequentially exerting dc capacitors energy and then WTs inertia via a cascading control...

  17. HVDC transmission power conversion applications in power systems

    CERN Document Server

    Kim, Chan-Ki; Jang, Gil-Soo; Lim, Seong-Joo; Lee, Seok-Jin

    2009-01-01

    HVDC is a critical solution to several major problems encountered when trying to maintain systemic links and quality in large-scale renewable energy environments. HDVC can resolve a number of issues, including voltage stability of AC power networks, reducing fault current, and optimal management of electric power, ensuring the technology will play an increasingly important role in the electric power industry. To address the pressing need for an up-to-date and comprehensive treatment of the subject, Kim, Sood, Jang, Lim and Lee have collaborated to produce this key text and reference.  Combin

  18. HVDC power transmission environmental issues review

    International Nuclear Information System (INIS)

    Bailey, W.H.; Weil, D.E.; Stewart, J.R.

    1997-04-01

    This report strives to define the various environmental effects associated with HVDC lines, discusses the current knowledge of their potential effects on biological and non-biological systems, and compares these effects associated with ac lines where appropriate

  19. HVDC power transmission environmental issues review

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, W.H.; Weil, D.E. [Bailey Research Associates, Inc., New York, NY (United States); Stewart, J.R. [Power Technologies, Inc., Schenectady, NY (United States)

    1997-04-01

    This report strives to define the various environmental effects associated with HVDC lines, discusses the current knowledge of their potential effects on biological and non-biological systems, and compares these effects associated with ac lines where appropriate.

  20. Hybrid HVDC (H2VDC System Using Current and Voltage Source Converters

    Directory of Open Access Journals (Sweden)

    José Rafael Lebre

    2018-05-01

    Full Text Available This paper presents an analysis of a new high voltage DC (HVDC transmission system, which is based on current and voltage source converters (CSC and VSC in the same circuit. This proposed topology is composed of one CSC (rectifier and one or more VSCs (inverters connected through an overhead transmission line in a multiterminal configuration. The main purpose of this Hybrid HVDC (H2VDC, as it was designed, is putting together the best benefits of both types of converters in the same circuit: no commutation failure and system’s black start capability in the VSC side, high power converter capability and low cost at the rectifier side, etc. A monopole of the H2VDC system with one CSC and two VSCs—here, the VSC is the Modular Multilevel Converter (MMC considered with full-bridge submodules—in multiterminal configuration is studied. The study includes theoretical analyses, development of the CSC and VSCs control philosophies and simulations. The H2VDC system’s behavior is analyzed by computational simulations considering steady-state operation and short-circuit conditions at the AC and DC side. The obtained results and conclusions show a promising system for very high-power multiterminal HVDC transmission.

  1. Operating characteristic analysis of a 400 mH class HTS DC reactor in connection with a laboratory scale LCC type HVDC system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung-Kyu, E-mail: power@changwon.ac.kr [Changwon National University, 55306 Sarim-dong, Changwon 641-773 (Korea, Republic of); Kim, Kwangmin; Park, Minwon [Changwon National University, 55306 Sarim-dong, Changwon 641-773 (Korea, Republic of); Yu, In-Keun, E-mail: yuik@changwon.ac.kr [Changwon National University, 55306 Sarim-dong, Changwon 641-773 (Korea, Republic of); Lee, Sangjin [Uiduk University, Gyeongju 780-713 (Korea, Republic of)

    2015-11-15

    Highlights: • A 400 mH class HTS DC reactor and a laboratory scale test-bed for line-commutated converter type HVDC transmission system. • The 400 mH class HTS DC reactor was connected to real power network via the HVDC system. • The DC current flowed in HTS DC reactor has several harmonic components and it was analyzed using FFT. - Abstract: High temperature superconducting (HTS) devices are being developed due to their advantages. Most line commutated converter based high voltage direct current (HVDC) transmission systems for long-distance transmission require large inductance of DC reactor; however, generally, copper-based reactors cause a lot of electrical losses during the system operation. This is driving researchers to develop a new type of DC reactor using HTS wire. The authors have developed a 400 mH class HTS DC reactor and a laboratory scale test-bed for line-commutated converter type HVDC system and applied the HTS DC reactor to the HVDC system to investigate their operating characteristics. The 400 mH class HTS DC reactor is designed using a toroid type magnet. The HVDC system is designed in the form of a mono-pole system with thyristor-based 12-pulse power converters. In this paper, the investigation results of the HTS DC reactor in connection with the HVDC system are described. The operating characteristics of the HTS DC reactor are analyzed under various operating conditions of the system. Through the results, applicability of an HTS DC reactor in an HVDC system is discussed in detail.

  2. Operating characteristic analysis of a 400 mH class HTS DC reactor in connection with a laboratory scale LCC type HVDC system

    International Nuclear Information System (INIS)

    Kim, Sung-Kyu; Kim, Kwangmin; Park, Minwon; Yu, In-Keun; Lee, Sangjin

    2015-01-01

    Highlights: • A 400 mH class HTS DC reactor and a laboratory scale test-bed for line-commutated converter type HVDC transmission system. • The 400 mH class HTS DC reactor was connected to real power network via the HVDC system. • The DC current flowed in HTS DC reactor has several harmonic components and it was analyzed using FFT. - Abstract: High temperature superconducting (HTS) devices are being developed due to their advantages. Most line commutated converter based high voltage direct current (HVDC) transmission systems for long-distance transmission require large inductance of DC reactor; however, generally, copper-based reactors cause a lot of electrical losses during the system operation. This is driving researchers to develop a new type of DC reactor using HTS wire. The authors have developed a 400 mH class HTS DC reactor and a laboratory scale test-bed for line-commutated converter type HVDC system and applied the HTS DC reactor to the HVDC system to investigate their operating characteristics. The 400 mH class HTS DC reactor is designed using a toroid type magnet. The HVDC system is designed in the form of a mono-pole system with thyristor-based 12-pulse power converters. In this paper, the investigation results of the HTS DC reactor in connection with the HVDC system are described. The operating characteristics of the HTS DC reactor are analyzed under various operating conditions of the system. Through the results, applicability of an HTS DC reactor in an HVDC system is discussed in detail.

  3. Optimal Power Transmission of Offshore Wind Power Using a VSC-HVdc Interconnection

    Directory of Open Access Journals (Sweden)

    Miguel E. Montilla-DJesus

    2017-07-01

    Full Text Available High-voltage dc transmission based on voltage-source converter (VSC-HVdc is quickly increasing its power rating, and it can be the most appropriate link for the connection of offshore wind farms (OWFs to the grid in many locations. This paper presents a steady-state operation model to calculate the optimal power transmission of an OWF connected to the grid through a VSC-HVdc link. The wind turbines are based on doubly fed induction generators (DFIGs, and a detailed model of the internal OWF grid is considered in the model. The objective of the optimization problem is to maximize the active power output of the OWF, i.e., the reduction of losses, by considering the optimal reactive power allocation while taking into account the restrictions imposed by the available wind power, the reactive power capability of the DFIG, the DC link model, and the operating conditions. Realistic simulations are performed to evaluate the proposed model and to execute optimal operation analyses. The results show the effectiveness of the proposed method and demonstrate the advantages of using the reactive control performed by DFIG to achieve the optimal operation of the VSC-HVdc.

  4. Cost and Benefit Analysis of VSC-HVDC Schemes for Offshore Wind Power Transmission

    Institute of Scientific and Technical Information of China (English)

    Sheng WANG; Chunmei FENG; An WEN; Jun LIANG

    2013-01-01

    Due to low load factors of wind power generation,it is possible to reduce transmission capacity to minimize the cost of transmission system construction.Two VSC-HVDC schemes for offshore wind farm,called the point to point (PTP) and DC mesh connections are compared in terms of the utilization of transmission system and its cost.A Weibull distribution is used for estimating offshore wind power generation,besides,the cross correlation between wind farms is considered.The wind energy curtailment is analyzed using the capacity output possibility table (COPT).The system power losses,costs of transmission investment and wind energy curtailment are also computed.A statistic model for the wind generation and transmission is built and simulated in MATLAB to validate the study.It is concluded that a DC mesh transmission can reduce the energy curtailment and power losses.Further benefit is achievable as the wind cross correlation between wind farms decreases.

  5. Offshore Wind Farms and HVDC Grids Modeling as a Feedback Control System for Stability Analysis

    DEFF Research Database (Denmark)

    Bidadfar, Ali; Saborío-Romano, Oscar; Altin, Müfit

    The low impedance characteristics of DC transmission lines cause the voltage source converter (VSC) in HVDC networks to become electrically closer together and increase the risk of severe interactions between the converters. Such interactions, in turn, intensify the implementation of the grid...... control schemes and may lead the entire system to instability. Assessing the stability and adopting complex coordinated control schemes in an HVDC grid and wind farm turbines are challenging and require a precise model of the HVDC grid, wind farm, and the controllers. In this paper, a linear multivariable...... feedback control system (FCS) model is proposed to represent the dynamic characteristics of HVDC grids and their controllers. The FCS model can be used for different dynamic analyses in time and frequency domains. Moreover, using the FCS model the system stability is analyzed in both open- and closed...

  6. Operating characteristic analysis of a 400 mH class HTS DC reactor in connection with a laboratory scale LCC type HVDC system

    Science.gov (United States)

    Kim, Sung-Kyu; Kim, Kwangmin; Park, Minwon; Yu, In-Keun; Lee, Sangjin

    2015-11-01

    High temperature superconducting (HTS) devices are being developed due to their advantages. Most line commutated converter based high voltage direct current (HVDC) transmission systems for long-distance transmission require large inductance of DC reactor; however, generally, copper-based reactors cause a lot of electrical losses during the system operation. This is driving researchers to develop a new type of DC reactor using HTS wire. The authors have developed a 400 mH class HTS DC reactor and a laboratory scale test-bed for line-commutated converter type HVDC system and applied the HTS DC reactor to the HVDC system to investigate their operating characteristics. The 400 mH class HTS DC reactor is designed using a toroid type magnet. The HVDC system is designed in the form of a mono-pole system with thyristor-based 12-pulse power converters. In this paper, the investigation results of the HTS DC reactor in connection with the HVDC system are described. The operating characteristics of the HTS DC reactor are analyzed under various operating conditions of the system. Through the results, applicability of an HTS DC reactor in an HVDC system is discussed in detail.

  7. Voltage sensitivity based reactive power control on VSC-HVDC in a wind farm connected hybrid multi-infeed HVDC system

    DEFF Research Database (Denmark)

    Liu, Yan; Chen, Zhe

    2013-01-01

    With increasing application of both Line Commutated Converter based High Voltage Direct Current (LCC-HVDC) systems and Voltage Source Converter based HVDC (VSC-HVDC) links, a new type of system structure named Hybrid Multi-Infeed HVDC (HMIDC) system is formed in the modern power systems. This paper...... presents the operation and control method of the wind farm connected HMIDC system. The wind power fluctuation takes large influence to the system voltages. In order to reduce the voltage fluctuation of LCC-HVDC infeed bus caused by the wind power variation, a voltage sensitivity-based reactive power...

  8. Control of transformerless MMC-HVDC during asymmetric grid faults

    DEFF Research Database (Denmark)

    Timofejevs, Artjoms; Gamboa, Daniel; Liserre, Marco

    2013-01-01

    Modular multilevel converter (MMC) is the latest converter topology suitable for the transformerless applications in HVDC transmission. HVDC systems are required to remain connected during grid faults, provide grid support and completely decouple the healthy side from the faulty one. The MMC...

  9. Modeling and simulation of large HVDC systems

    Energy Technology Data Exchange (ETDEWEB)

    Jin, H.; Sood, V.K.

    1993-01-01

    This paper addresses the complexity and the amount of work in preparing simulation data and in implementing various converter control schemes and the excessive simulation time involved in modelling and simulation of large HVDC systems. The Power Electronic Circuit Analysis program (PECAN) is used to address these problems and a large HVDC system with two dc links is simulated using PECAN. A benchmark HVDC system is studied to compare the simulation results with those from other packages. The simulation time and results are provided in the paper.

  10. A Review of LCC-HVDC and VSC-HVDC Technologies and Applications

    Directory of Open Access Journals (Sweden)

    Oluwafemi Emmanuel Oni

    2016-09-01

    Full Text Available High Voltage Direct Current (HVDC systems has been an alternative method of transmitting electric power from one location to another with some inherent advantages over AC transmission systems. The efficiency and rated power carrying capacity of direct current transmission lines highly depends on the converter used in transforming the current from one form to another (AC to DC and vice versa. A well configured converter reduces harmonics, increases power transfer capabilities, and reliability in that it offers high tolerance to fault along the line. Different HVDC converter topologies have been proposed, built and utilised all over the world. The two dominant types are the line commutated converter LCC and the voltage source converter VSC. This review paper evaluates these two types of converters, their operational characteristics, power rating capability, control capability and losses. The balance of the paper addresses their applications, advantages, limitations and latest developments with these technologies.

  11. Enhancing the reliability of AC transmission networks by using a long distance HVDC-link

    Energy Technology Data Exchange (ETDEWEB)

    Fleckenstein, Marco; Balzer, Gerd; Wasserrab, Andreas; Neumann, Claus [Technische Univ. Darmstadt (Germany). Inst. of Electrical Power and Energy

    2012-07-01

    The absorption of energy from offshore wind farms is a difficult task for Transmission system operators (TSO) in Germany, even if no offshore wind farm is connected directly. The role of the TSOs in the north it is to transport this energy to the south of Germany. The transmission capacities of overhead lines are limited. With the expected rapid expansion of wind farms, this is no longer enough. Thus, the transmission system must be enhanced. One possibility is the installation of an HVDC link from north to south between two main substations in the 380 kV network. Based on a realistic case study, the impact of such a link on the reliability of the entire extra high voltage network is shown. (orig.)

  12. HVDC grids for offshore and supergrid of the future

    CERN Document Server

    Gomis-Bellmunt, Oriol; Liang, Jun

    2016-01-01

    Presents the advantages, challenges, and technologies of High Voltage Direct Current (HVDC) Grids This book discusses HVDC grids based on multi-terminal voltage-source converters (VSC), which is suitable for the connection of offshore wind farms and a possible solution for a continent wide overlay grid. HVDC Grids: For Offshore and Supergrid of the Future begins by introducing and analyzing the motivations and energy policy drives for developing offshore grids and the European Supergrid. HVDC transmission technology and offshore equipment are described in the second part of the book. The third part of the book discusses how HVDC grids can be developed and integrated in the existing power system. The fourth part of the book focuses on HVDC grid integration, in studies, for different time domains of electric power systems. The book concludes by discussing developments of advanced control methods and control devices for enabling DC grids.

  13. AC Transmission Emulation Control Strategies for the BTB VSC HVDC System in the Metropolitan Area of Seoul

    Directory of Open Access Journals (Sweden)

    Sungyoon Song

    2017-08-01

    Full Text Available In the Korean power system, growing power loads have recently created the problems of voltage instability and fault current in the Seoul Capital Area (SCA. Accordingly, the back-to-back (BTB voltage source converter (VSC high-voltage direct-current (HVDC system is emerging to resolve such problems with grid segmentation. However, non-convergence problems occur in this metropolitan area, due to the large change of power flow in some contingencies. Therefore, this paper proposes two kinds of AC transmission emulation control (ATEC strategies to improve the metropolitan transient stability, and to resolve the non-convergence problem. The proposed ATEC strategies are able to mitigate possible overloading of adjacent AC transmission, and maintain power balance between metropolitan regions. The first ATEC strategy uses a monitoring system that permits the reverse power flow of AC transmission, and thus effectively improves the grid stability based on the power transfer equation. The second ATEC strategy emulates AC transmission with DC link capacitors in a permissible DC-link voltage range according to angle difference, and securely improves the gird stability, without requiring grid operator schedule decisions. This paper compares two kinds of ATEC schemes: it demonstrates the first ATEC strategy with specific fault scenario with PSS/E (Power Transmission System Planning Software, and evaluates the second ATEC strategy with internal controller performance with PSCAD/EMTDC (Power System Electromagnetic Transients Simulation Software.

  14. Non-Pilot Protection of the HVDC Grid

    Science.gov (United States)

    Badrkhani Ajaei, Firouz

    This thesis develops a non-pilot protection system for the next generation power transmission system, the High-Voltage Direct Current (HVDC) grid. The HVDC grid protection system is required to be (i) adequately fast to prevent damages and/or converter blocking and (ii) reliable to minimize the impacts of faults. This study is mainly focused on the Modular Multilevel Converter (MMC) -based HVDC grid since the MMC is considered as the building block of the future HVDC systems. The studies reported in this thesis include (i) developing an enhanced equivalent model of the MMC to enable accurate representation of its DC-side fault response, (ii) developing a realistic HVDC-AC test system that includes a five-terminal MMC-based HVDC grid embedded in a large interconnected AC network, (iii) investigating the transient response of the developed test system to AC-side and DC-side disturbances in order to determine the HVDC grid protection requirements, (iv) investigating the fault surge propagation in the HVDC grid to determine the impacts of the DC-side fault location on the measured signals at each relay location, (v) designing a protection algorithm that detects and locates DC-side faults reliably and sufficiently fast to prevent relay malfunction and unnecessary blocking of the converters, and (vi) performing hardware-in-the-loop tests on the designed relay to verify its potential to be implemented in hardware. The results of the off-line time domain transients studies in the PSCAD software platform and the real-time hardware-in-the-loop tests using an enhanced version of the RTDS platform indicate that the developed HVDC grid relay meets all technical requirements including speed, dependability, security, selectivity, and robustness. Moreover, the developed protection algorithm does not impose considerable computational burden on the hardware.

  15. First hvdc underwater transmission links mainland and Vancouver

    Energy Technology Data Exchange (ETDEWEB)

    1967-06-01

    Delicate and complex equipment for North America's first hvdc underwater transmission line is being installed. The power link will connect British Columbia Hydro and power authority's switchyards on the mainland near Ladner with the western terminus of the transmission scheme at Duncan on Vancouver Island, a distance of 42 miles. Nearly 19 miles of the transmission will be underwater, between Tsawwassen and Galiano Island, and between Parker and Saltspring Islands. The remaining distance will be spanned by a conventional aerial conductor. The submarine conductor cable will be approximately 3-1/2 inches in diameter and its copper core will be sheathed in lead and armored with a ring of steel wire. The cable, which is being manufactured in Calais, France, and coiled in a planned sequence aboard the cable laying vessel, Marcel Bayard, will be placed across the Gulf of Georgia in the spring of 1968.

  16. A Review on VSC-HVDC Reliability Modeling and Evaluation Techniques

    Science.gov (United States)

    Shen, L.; Tang, Q.; Li, T.; Wang, Y.; Song, F.

    2017-05-01

    With the fast development of power electronics, voltage-source converter (VSC) HVDC technology presents cost-effective ways for bulk power transmission. An increasing number of VSC-HVDC projects has been installed worldwide. Their reliability affects the profitability of the system and therefore has a major impact on the potential investors. In this paper, an overview of the recent advances in the area of reliability evaluation for VSC-HVDC systems is provided. Taken into account the latest multi-level converter topology, the VSC-HVDC system is categorized into several sub-systems and the reliability data for the key components is discussed based on sources with academic and industrial backgrounds. The development of reliability evaluation methodologies is reviewed and the issues surrounding the different computation approaches are briefly analysed. A general VSC-HVDC reliability evaluation procedure is illustrated in this paper.

  17. HVDC System Characteristics and Simulation Models

    Energy Technology Data Exchange (ETDEWEB)

    Moon, S.I.; Han, B.M.; Jang, G.S. [Electric Enginnering and Science Research Institute, Seoul (Korea)

    2001-07-01

    This report deals with the AC-DC power system simulation method by PSS/E and EUROSTAG for the development of a strategy for the reliable operation of the Cheju-Haenam interconnected system. The simulation using both programs is performed to analyze HVDC simulation models. In addition, the control characteristics of the Cheju-Haenam HVDC system as well as Cheju AC system characteristics are described in this work. (author). 104 figs., 8 tabs.

  18. Offshore Wind Farms and HVDC Grids Modeling as a Feedback Control System for Stability Analysis

    OpenAIRE

    Bidadfar, Ali; Saborío-Romano, Oscar; Altin, Müfit; Göksu, Ömer; Cutululis, Nicolaos Antonio; Sørensen, Poul Ejnar

    2017-01-01

    The low impedance characteristics of DC transmission lines cause the voltage source converter (VSC) in HVDC networks to become electrically closer together and increase the risk of severe interactions between the converters. Such interactions, in turn, intensify the implementation of the grid control schemes and may lead the entire system to instability. Assessing the stability and adopting complex coordinated control schemes in an HVDC grid and wind farm turbines are challenging and require ...

  19. High-performance HVDC transmission over long distances; Hochleistungsuebertragung ueber grosse Entfernungen mit hochgespanntem Gleichstrom

    Energy Technology Data Exchange (ETDEWEB)

    Radtke, U. [PreussenElektra AG, Hannover (Germany)

    1998-12-31

    High-voltage DC transmission is a world-wide established technology for low-cost transmission of large amounts of electricity over long distances. Thanks to HVDC transmission, large amounts of electricity can now for the first time also be transmitted over long distances via ocean cable, something that cannot be done with AC power cables. HVDC transmission is independent of grid frequencies and can link grids of different frequency and different quality of frequency. Interconnected grids coupled via DC circuits can exploit additional technical and economic advantages such as mutual supply of power reserves, balancing of peak load, and modulation of active and reactive power. (orig.) [Deutsch] Die Hochspannungs-Gleichstromuebertragung (HGUe) ist eine weltweit etablierte Technik zur kostenguenstigen Uebertragung grosser elektrischer Leistungen ueber grosse Entfernungen. Sie schafft erstmals die Moeglichkeit, auch mittels Seekabel grosse Leistungen ueber Entfernungen zu uebertragen, die mit der Drehstromtechnik nicht moeglich sind. HGUeist unabhaengig von den Netzfrequenzen und kann Netze unterschiedlicher Frequenz und Frequenzguete miteinander verbinden. Ueber Gleichstromkreise gekuppelte Verbundnetze koennen zusaetzliche technische und wirtschaftliche Vorteile wie gegenseitige Bereitstellung von Kraftwerksreserven, Spitzenlastausgleich sowie Wirk- und Blindleistungsmodulation nutzt. (orig.)

  20. High-voltage direct current (HVDC) transmission - a key technology for our power supply

    International Nuclear Information System (INIS)

    Dorn, J.

    2016-01-01

    The phasing-out of nuclear power in some countries and the aspirations of reducing carbon dioxide emissions have far-reaching implications for electric power generation in Europe. In the future, renewable electricity generation will account for a considerable share of the energy mix, but this type of production is often far from the load centers. In Germany, for example, large quantities of wind energy are already generated in the north and in the North Sea, but large load centers are located several hundred kilometers south of there. This requires an expansion of the transmission network with innovative solutions. High-voltage direct-current (HVDC) transmission plays an important role, since it brings a number of advantages over conventional AC technology and makes certain requirements feasible, for example Cable transmission over longer distances. The lecture presents the advantages of HVDC, the semiconductors used as well as the basic functions and typical performance of the used converter topopologies. The plant configurations and main components are illustrated using current projects. (rössner) [de

  1. Calculation of large ion densities under HVdc transmission lines by the finite difference method

    International Nuclear Information System (INIS)

    Suda, Tomotaka; Sunaga, Yoshitaka

    1995-01-01

    A calculation method for large ion densities (charged aerosols) under HVdc transmission lines was developed considering both the charging mechanism of aerosols by small ions and the drifting process by wind. Large ion densities calculated by this method agreed well with the ones measured under the Shiobara HVdc test line on the lateral profiles at ground level up to about 70m downwind from the line. Measured values decreased more quickly than calculated ones farther downwind from the line. Considering the effect of point discharge from ground cover (earth corona) improved the agreement in the farther downwind region

  2. Research on the correlation between corona current spectrum and audible noise spectrum of HVDC transmission line

    Science.gov (United States)

    Liu, Yingyi; Zhou, Lijuan; Liu, Yuanqing; Yuan, Haiwen; Ji, Liang

    2017-11-01

    Audible noise is closely related to corona current on a high voltage direct current (HVDC) transmission line. In this paper, we measured a large amount of audible noise and corona current waveforms simultaneously based on the largest outdoor HVDC corona cage all over the world. By analyzing the experimental data, the related statistical regularities between a corona current spectrum and an audible noise spectrum were obtained. Furthermore, the generation mechanism of audible noise was analyzed theoretically, and the related mathematical expression between the audible noise spectrum and the corona current spectrum, which is suitable for all of these measuring points in the space, has been established based on the electro-acoustic conversion theory. Finally, combined with the obtained mathematical relation, the internal reasons for these statistical regularities appearing in measured corona current and audible noise data were explained. The results of this paper not only present the statistical association regularities between the corona current spectrum and the audible noise spectrum on a HVDC transmission line, but also reveal the inherent reasons of these associated rules.

  3. High voltage direct current transmission converters, systems and DC grids

    CERN Document Server

    Jovcic, Dragan

    2015-01-01

    This comprehensive reference guides the reader through all HVDC technologies, including LCC (Line Commutated Converter), 2-level VSC and VSC HVDC based on modular multilevel converters (MMC) for an in-depth understanding of converters, system level design, operating principles and modeling. Written in a tutorial style, the book also describes the key principles of design, control, protection and operation of DC transmission grids, which will be substantially different from the practice with AC transmission grids. The first dedicated reference to the latest HVDC technologies and DC grid developments; this is an essential resource for graduate students and researchers as well as engineers and professionals working on the design, modeling and operation of DC grids and HVDC.

  4. Research on hybrid transmission mode for HVDC with optimal thermal power and renewable energy combination

    Science.gov (United States)

    Zhang, Jinfang; Yan, Xiaoqing; Wang, Hongfu

    2018-02-01

    With the rapid development of renewable energy in Northwest China, curtailment phenomena is becoming more and more serve owing to lack of adjustment ability and enough transmission capacity. Based on the existing HVDC projects, exploring the hybrid transmission mode associated with thermal power and renewable power will be necessary and important. This paper has proposed a method on optimal thermal power and renewable energy combination for HVDC lines, based on multi-scheme comparison. Having established the mathematic model for electric power balance in time series mode, ten different schemes have been picked for figuring out the suitable one by test simulation. By the proposed related discriminated principle, including generation device utilization hours, renewable energy electricity proportion and curtailment level, the recommendation scheme has been found. The result has also validated the efficiency of the method.

  5. Offshore grid transmission planning using approximated HVDC power flows

    Energy Technology Data Exchange (ETDEWEB)

    Torbaghan, Shahab Shariat; Rawn, Barry G.; Gibescu, Madeleine; Meijden, Mart van der [Delft Univ. of Technology (Netherlands). Dept. of Electrical Sustainable Energy

    2012-07-01

    In this paper we introduce an optimization framework which determines a socially optimum design of a HVDC offshore grid, under the assumption of a centralized network expansion planning scheme. This gives the optimum grid topology and interconnections capacity. In addition, the analytical solution to the optimization problem yields a market structure that expresses the relationship between the different regions' electricity prices and congestion charges associated with the interconnections. The optimization model sets the transmission capacities in a way that congestion shadow prices to be collected by the end of the economic lifetime of the project pay off the initial investment capital. We use this framework to study the impact of exercising different dispatching policies on the optimum design of the grid. The framework is applied to a multi-bus test system that functions under 8 different time periods. (orig.)

  6. improvement of power system quality using vsc-based hvdc

    African Journals Online (AJOL)

    HOD

    transmission is its ability to independently control the reactive and real power flow ... Key words: HVDC, Voltage source converter (VSC), Current and Voltage Control Loop; FFT Analysis ..... waveform and FFT wave spectrum, the DC side filters.

  7. Power system integration of VSC-HVDC connected offshore wind power plants

    DEFF Research Database (Denmark)

    Zeni, Lorenzo; Kjær, Philip Carne

    This report presents an overview of challenges and solutions for the integration into the power system of offshore wind power plants (WPPs) connected to onshore grids through a voltage-source converter based high voltage direct current (VSC-HVDC) transmission system. Aspects that are touched upon...... of the network in the vicinity of the HVDC station and (iii) limiting characteristics of WPPs such as inherent control and communication delays, presence of mechanical resonances at the same frequency as POD and active power ramp-rate limitations. Clustering of wind power plants The proof of concept...... introduction to justify the study, describe the state-of-art and formulate the project’s objectives, the report is essentially divided into three parts, as follows. Control principles of offshore AC networks The control of offshore AC networks relies purely on power electronics, especially if Type 4 wind...

  8. Modeling of HVDC in Dynamic State Estimation Using Unscented Kalman Filter Method

    DEFF Research Database (Denmark)

    Khazraj, Hesam; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2016-01-01

    HVDC transmission is an integral part of various power system networks. This article presents an Unscented Kalman Filter dynamic state estimator algorithm that considers the presence of HVDC links. The AC - DC power flow analysis, which is implemented as power flow solver for Dynamic State...

  9. Transient analysis of an HTS DC power cable with an HVDC system

    Science.gov (United States)

    Dinh, Minh-Chau; Ju, Chang-Hyeon; Kim, Jin-Geun; Park, Minwon; Yu, In-Keun; Yang, Byeongmo

    2013-11-01

    The operational characteristics of a superconducting DC power cable connected to a highvoltage direct current (HVDC) system are mainly concerned with the HVDC control and protection system. To confirm how the cable operates with the HVDC system, verifications using simulation tools are needed. This paper presents a transient analysis of a high temperature superconducting (HTS) DC power cable in connection with an HVDC system. The study was conducted via the simulation of the HVDC system and a developed model of the HTS DC power cable using a real time digital simulator (RTDS). The simulation was performed with some cases of short circuits that may have caused system damage. The simulation results show that during the faults, the quench did not happen with the HTS DC power cable because the HVDC controller reduced some degree of the fault current. These results could provide useful data for the protection design of a practical HVDC and HTS DC power cable system.

  10. Analysis of control alternatives for offshore wind farms connected through a VSC-HVDC link

    Energy Technology Data Exchange (ETDEWEB)

    Belenguer, Enrique; Vidal, Ricardo; Beltran, Hector [Jaume I Univ., Castellon de la Plana (Spain). Dept. of Industrial Engineering Systems; Blasco-Gimenez, Ramon [Univ. Politecnica de Valencia (Spain). Dept. of Systems Engineering and Control

    2012-07-01

    The use of VSC-HVDC transmission systems for the connection of offshore wind power plants increases the control capabilities of the whole system with respect to the use of standard LCC-HVDC systems. In this paper two different control strategies for an offshore wind farm connected through a VSC-HVDC link have been developed and analyzed through PSCAD simulations. Both, steady state and transient behavior have been simulated in order to find the best control strategy for such a system. (orig.)

  11. Voltage Balancing Method on Expert System for 51-Level MMC in High Voltage Direct Current Transmission

    Directory of Open Access Journals (Sweden)

    Yong Chen

    2016-01-01

    Full Text Available The Modular Multilevel Converters (MMC have been a spotlight for the high voltage and high power transmission systems. In the VSC-HVDC (High Voltage Direct Current based on Voltage Source Converter transmission system, the energy of DC link is stored in the distributed capacitors, and the difference of capacitors in parameters and charge rates causes capacitor voltage balance which affects the safety and stability of HVDC system. A method of MMC based on the expert system for reducing the frequency of the submodules (SMs of the IGBT switching frequency is proposed. Firstly, MMC with 51 levels for HVDC is designed. Secondly, the nearest level control (NLC for 51-level MMC is introduced. Thirdly, a modified capacitor voltage balancing method based on expert system for MMC-based HVDC transmission system is proposed. Finally, a simulation platform for 51-level Modular Multilevel Converter is constructed by using MATLAB/SIMULINK. The results indicate that the strategy proposed reduces the switching frequency on the premise of keeping submodule voltage basically identical, which greatly reduces the power losses for MMC-HVDC system.

  12. Second Order Cone Programming (SOCP) Relaxation Based Optimal Power Flow with Hybrid VSC-HVDC Transmission and Active Distribution Networks

    DEFF Research Database (Denmark)

    Ding, Tao; Li, Cheng; Yang, Yongheng

    2017-01-01

    The detailed topology of renewable resource bases may have the impact on the optimal power flow of the VSC-HVDC transmission network. To address this issue, this paper develops an optimal power flow with the hybrid VSC-HVDC transmission and active distribution networks to optimally schedule...... the generation output and voltage regulation of both networks, which leads to a non-convex programming model. Furthermore, the non-convex power flow equations are based on the Second Order Cone Programming (SOCP) relaxation approach. Thus, the proposed model can be relaxed to a SOCP that can be tractably solved...

  13. Multilevel Modular Converter for VSC-HVDC Transmission Applications: Control and Operational Aspects

    DEFF Research Database (Denmark)

    Gnanarathna, Udana N.; Gole, Aniruddha M.; Chaudhary, Sanjay Kumar

    2010-01-01

    Control methods for a new class of converter, the multilevel modular converter (MMC), recently introduced for HVDC transmission are discussed. The paper discusses converter-level controls including firing pulse generation and capacitor voltage balancing. It also covers higher level controls...... for incorporating the converter into a larger power network, with a weak ac receiving end. The performance behavior is studied using electromagnetic transients simulation....

  14. Transient analysis of an HTS DC power cable with an HVDC system

    International Nuclear Information System (INIS)

    Dinh, Minh-Chau; Ju, Chang-Hyeon; Kim, Jin-Geun; Park, Minwon; Yu, In-Keun; Yang, Byeongmo

    2013-01-01

    Highlights: •A model of an HTS DC power cable was developed using real time digital simulator. •The simulations of the HTS DC power cable in connection with an HVDC system were performed. •The transient analysis results of the HTS DC power cable were presented. -- Abstract: The operational characteristics of a superconducting DC power cable connected to a highvoltage direct current (HVDC) system are mainly concerned with the HVDC control and protection system. To confirm how the cable operates with the HVDC system, verifications using simulation tools are needed. This paper presents a transient analysis of a high temperature superconducting (HTS) DC power cable in connection with an HVDC system. The study was conducted via the simulation of the HVDC system and a developed model of the HTS DC power cable using a real time digital simulator (RTDS). The simulation was performed with some cases of short circuits that may have caused system damage. The simulation results show that during the faults, the quench did not happen with the HTS DC power cable because the HVDC controller reduced some degree of the fault current. These results could provide useful data for the protection design of a practical HVDC and HTS DC power cable system

  15. Transient analysis of an HTS DC power cable with an HVDC system

    Energy Technology Data Exchange (ETDEWEB)

    Dinh, Minh-Chau, E-mail: thanchau7787@gmail.com [Department of Electrical Engineering, Changwon National University, 9 Sarim-Dong, Changwon 641-773 (Korea, Republic of); Ju, Chang-Hyeon; Kim, Jin-Geun; Park, Minwon [Department of Electrical Engineering, Changwon National University, 9 Sarim-Dong, Changwon 641-773 (Korea, Republic of); Yu, In-Keun, E-mail: yuik@cwnu.ac.kr [Department of Electrical Engineering, Changwon National University, 9 Sarim-Dong, Changwon 641-773 (Korea, Republic of); Yang, Byeongmo [Korea Electric Power Research Institute, 105 Munji-Ro, Yuseong-Gu, Daejon 305-760 (Korea, Republic of)

    2013-11-15

    Highlights: •A model of an HTS DC power cable was developed using real time digital simulator. •The simulations of the HTS DC power cable in connection with an HVDC system were performed. •The transient analysis results of the HTS DC power cable were presented. -- Abstract: The operational characteristics of a superconducting DC power cable connected to a highvoltage direct current (HVDC) system are mainly concerned with the HVDC control and protection system. To confirm how the cable operates with the HVDC system, verifications using simulation tools are needed. This paper presents a transient analysis of a high temperature superconducting (HTS) DC power cable in connection with an HVDC system. The study was conducted via the simulation of the HVDC system and a developed model of the HTS DC power cable using a real time digital simulator (RTDS). The simulation was performed with some cases of short circuits that may have caused system damage. The simulation results show that during the faults, the quench did not happen with the HTS DC power cable because the HVDC controller reduced some degree of the fault current. These results could provide useful data for the protection design of a practical HVDC and HTS DC power cable system.

  16. Comparison of alternative offshore wind farms and HVDC systems

    Energy Technology Data Exchange (ETDEWEB)

    Bruns, M. [Technische Univ. Dresden (Germany); Lilje, P.; Poeller, M. [DIgSILENT GmbH, Gomaringen (Germany); Basteck, A. [Voith Turbo Wind GmbH und Co. KG, Crailsheim (Germany)

    2010-07-01

    This paper investigates the stability of offshore wind farms connected to the main power system via HVDC systems. Wind farms consisting of different ratios of directly connected synchronous machines and doubly-fed induction machines are considered. In addition, both conventional LCC- and VSC-type HVDC systems are considered. Furthermore, different control strategies are considered. Furthermore, different control strategies are considered for the VSC-based system, including constant frequency control and frequency regulation. The stability analysis is done by means of time-domain simulation. The maximum and minimum ratio of the two wind turbine technologies is found for each of the different HVDC systems. (orig.)

  17. Modelisation et simulation d'une liaison HVDC de type VSC-MMC

    Science.gov (United States)

    Saad, Hani Aziz

    High-voltage direct current transmission systems (HVDC) are rapidly expanding in the world. Two main factors are responsible for this expansion. The first is related to the difficulty of building new overhead lines to ensure the development of high-voltage AC grids, which makes the usage of underground cables more common. However, the use of such cables is limited in length to a few tens of km because of the capacitive current generated by the cable itself. Beyond this length limit, the solution is usually to transmit in DC. The second factor is related to the development of offshore wind power plants that require connecting powers of several hundred of MW to the mainland grid by cables whose lengths can reach several hundreds of km and consequently require HVDC transmission system. Several HVDC projects are currently planned and developed by the French transmission system operator RTE. One of such projects is the INELFE interconnection project, with a capacity of 2,000 MW, between France and Spain. This thesis has been funded by RTE, in order to model and simulate in off-line and real time modes, modern HVDC interconnections. The delivered simulation means are used to examine targeted HVDC system performances and risks of abnormal interactions with surrounding power systems. The particularity of the INELFE HVDC system is the usage of a dedicated control system that will largely determine the dynamic behaviour of the system for both large disturbances (faults on the network) and small perturbations (power step changes). Various VSC topologies, including the conventional two-level, multi-level diode-clamped and floating capacitor multi-level converters, have been proposed and reported in the literature. However, due to the complexity of controls and practical limitations, the VSC-HVDC system installations have been limited to the two-level and three-level diode-clamped converters. Recently, the development of modular technology called MMC (Modular Multilevel

  18. Steady-state and transient performance of HVDC link based 3-level ...

    African Journals Online (AJOL)

    Administrateur

    DC (HVDC) transmission systems based on three-level voltage source converters. The study involves ..... voltage drops due to the currents across the impedance .... IEEE/PES Transmission and Distribution Conference &. Exhibition: Asia and ...

  19. HVDC: A key solution in future transmission systems

    Energy Technology Data Exchange (ETDEWEB)

    Heyman, Olof H.; Weimers, Lars; Bohl, Mie-Lotte

    2010-09-15

    With the transition of power grids, based on sustainable generation, HVDC is a key technology with new applications. This includes connection of remote wind parks and strengthening of existing AC grids. In addition, traditional applications, such as bulk hydropower transfer and interconnections between regions, play a major role in our transition to sustainable generation and the associated grids. The technology for regional grids with a limited number of nodes is already in place and commercial projects are commissioned. For extensive grids, development and verification are ongoing in parallel to industry standards being discussed in groups such as ENTSO-E and CIGRE.

  20. HVDC Solution for Offshore Wind Park Comprising Turbines Equipped with Full-Range Converters

    DEFF Research Database (Denmark)

    Sharma, Ranjan; Rasmussen, Tonny Wederberg; Jensen, Kim Høj

    2010-01-01

    a voltage drop is created at the collection grid, the wind turbines go into fault-ride-through mode. The power output from each of the wind turbines is thus reduced to balance the system power. The detailed explanation of the strategy is presented in the paper. Matlab simulation model was prepared and some...... of a HVDC transmission system. The power system under study includes an offshore wind farm comprising turbines equipped with full range converters. The collection network is a local AC grid. Power transmission is done through HVDC system. The grid side VSC (voltage source converter) controls the DC voltage...

  1. Relative localization in wireless sensor networks for measurement of electric fields under HVDC transmission lines.

    Science.gov (United States)

    Cui, Yong; Wang, Qiusheng; Yuan, Haiwen; Song, Xiao; Hu, Xuemin; Zhao, Luxing

    2015-02-04

    In the wireless sensor networks (WSNs) for electric field measurement system under the High-Voltage Direct Current (HVDC) transmission lines, it is necessary to obtain the electric field distribution with multiple sensors. The location information of each sensor is essential to the correct analysis of measurement results. Compared with the existing approach which gathers the location information by manually labelling sensors during deployment, the automatic localization can reduce the workload and improve the measurement efficiency. A novel and practical range-free localization algorithm for the localization of one-dimensional linear topology wireless networks in the electric field measurement system is presented. The algorithm utilizes unknown nodes' neighbor lists based on the Received Signal Strength Indicator (RSSI) values to determine the relative locations of nodes. The algorithm is able to handle the exceptional situation of the output permutation which can effectively improve the accuracy of localization. The performance of this algorithm under real circumstances has been evaluated through several experiments with different numbers of nodes and different node deployments in the China State Grid HVDC test base. Results show that the proposed algorithm achieves an accuracy of over 96% under different conditions.

  2. Relative Localization in Wireless Sensor Networks for Measurement of Electric Fields under HVDC Transmission Lines

    Directory of Open Access Journals (Sweden)

    Yong Cui

    2015-02-01

    Full Text Available In the wireless sensor networks (WSNs for electric field measurement system under the High-Voltage Direct Current (HVDC transmission lines, it is necessary to obtain the electric field distribution with multiple sensors. The location information of each sensor is essential to the correct analysis of measurement results. Compared with the existing approach which gathers the location information by manually labelling sensors during deployment, the automatic localization can reduce the workload and improve the measurement efficiency. A novel and practical range-free localization algorithm for the localization of one-dimensional linear topology wireless networks in the electric field measurement system is presented. The algorithm utilizes unknown nodes’ neighbor lists based on the Received Signal Strength Indicator (RSSI values to determine the relative locations of nodes. The algorithm is able to handle the exceptional situation of the output permutation which can effectively improve the accuracy of localization. The performance of this algorithm under real circumstances has been evaluated through several experiments with different numbers of nodes and different node deployments in the China State Grid HVDC test base. Results show that the proposed algorithm achieves an accuracy of over 96% under different conditions.

  3. Hard- and software of real time simulation tools of Electric Power System for adequate modeling power semiconductors in voltage source convertor based HVDC and FACTS

    Directory of Open Access Journals (Sweden)

    Ufa Ruslan A.

    2014-01-01

    Full Text Available The motivation of the presented research is based on the needs for development of new methods and tools for adequate simulation of Flexible Alternating Current Transmission System (FACTS devices and High Voltage Direct Current Transmission (HVDC system as part of real electric power systems (EPS. For that, a hybrid approach for advanced simulation of the FACTS and HVDC based on Voltage Source is proposed. The presented simulation results of the developed hybrid model of VSC confirm the achievement of the desired properties of the model and the effectiveness of the proposed solutions.

  4. Examination of fault ride-through methods for off-shore wind farms connected to the grid through VSC-based HVDC transmission

    Energy Technology Data Exchange (ETDEWEB)

    Karaagac, U.; Mahseredjian, J.; Saad, H. [Ecole Polytechnique de Montreal, QC (Canada); Jensen, S.; Cai, L. [REpower Systems AG, Hamburg (Germany)

    2012-07-01

    The fault ride-through (FRT) performance of offshore wind farms (OWFs) is a challenging task when the OWF is connected to the onshore ac grid through a voltage source converter (VSC) based HVDC transmission system. The injected power from the OWF cannot be reduced by the offshore VSC during onshore ac faults and this causes a fast increase in the dc network voltage. Without any special FRT method, the dc network voltage may increase up to intolerable levels and cause operation of dc overvoltage protection. This paper compares various FRT methods based on fast reduction of power generation in OWFs. In addition, this paper proposes an improved FRT method based on controlled voltage drop for output power reduction in OWFs. The proposed improvement reduces mechanical stress on the wind turbine (WT) drive train, and electrical stress on the insulated gate bipolar transistors (IGBTs) of the HVDC and doubly-fed induction generator (DFIG) converters. Practical onshore ac fault scenarios are simulated for an OWF composed of DFIG type WTs and connected to a practical ac grid through a point-to-point modular multilevel converter (MMC) based HVDC system. (orig.)

  5. An Examination of AC/HVDC Power Circuits for Interconnecting Bulk Wind Generation with the Electric Grid

    Directory of Open Access Journals (Sweden)

    Daniel Ludois

    2010-06-01

    Full Text Available The application of high voltage dc (HVDC transmission for integrating large scale and/or off-shore wind generation systems with the electric grid is attractive in comparison to extra high voltage (EHV ac transmission due to a variety of reasons. While the technology of classical current sourced converters (CSC using thyristors is well established for realization of large HVDC systems, the technology of voltage sourced converters (VSC is emerging to be an alternative approach, particularly suitable for multi-terminal interconnections. More recently, a more modular scheme that may be termed ‘bridge of bridge’ converters (BoBC has been introduced to realize HVDC systems. While all these three approaches are functionally capable of realizing HVDC systems, the converter power circuit design trade-offs between these alternatives are not readily apparent. This paper presents an examination of these topologies from the point of view of power semiconductor requirements, reactive component requirements, operating losses, fault tolerance, multi-terminal operation, modularity, complexity, etc. Detailed analytical models will be used along with a benchmark application to develop a comparative evaluation of the alternatives that maybe used by wind energy/bulk transmission developers for performing engineering trade-off studies.

  6. OPF-Based Optimal Location of Two Systems Two Terminal HVDC to Power System Optimal Operation

    Directory of Open Access Journals (Sweden)

    Mehdi Abolfazli

    2013-04-01

    Full Text Available In this paper a suitable mathematical model of the two terminal HVDC system is provided for optimal power flow (OPF and optimal location based on OPF such power injection model. The ability of voltage source converter (VSC-based HVDC to independently control active and reactive power is well represented by the model. The model is used to develop an OPF-based optimal location algorithm of two systems two terminal HVDC to minimize the total fuel cost and active power losses as objective function. The optimization framework is modeled as non-linear programming (NLP and solved by Matlab and GAMS softwares. The proposed algorithm is implemented on the IEEE 14- and 30-bus test systems. The simulation results show ability of two systems two terminal HVDC in improving the power system operation. Furthermore, two systems two terminal HVDC is compared by PST and OUPFC in the power system operation from economical and technical aspects.

  7. Stability Enhancement of Multi machine AC Systems by Synchronverter HVDC control

    Directory of Open Access Journals (Sweden)

    Raouia Aouini

    2016-06-01

    Full Text Available This paper investigates the impact of the Synchronverter based HVDC control on power system stability. The study considers multi machine power systems, with realistic parameters. A specific tuning method of the parameters of the regulators is used. The proposed control scheme is based on the sensitivity of the poles of the HVDC neighbor zone to the control parameters, and next, on their placement using residues. The transient stability of the HVDC neighbor zone is a priori taken into account at the design stage. The new tuning method is evaluated in comparison with the standard vector control via simulation tests. Extensive tests are performed using Matlab/Simulink implementation of the IEEE 9 bus/3 machines test system. The results prove the superiority of the proposed control to the classic vector control. The synchronverter control allows to improve not only the local performances of the HVDC link, but also the overall transient stability of the AC zone in which the HVDC is inserted. (where

  8. Study on VSC HVDC Modeling and Control Strategies for Wind Power Integration

    DEFF Research Database (Denmark)

    Korompili, Asimenia; Wu, Qiuwei

    Recently, more and more offshore wind farms have been integrated to the power systems. In the next years, these offshore power plants are going to be rated at higher capacities and located in larger distances from the coast. This results in greater interest in the transmission technologies, which....... Finally, more specific requirements are given for the grid connection of offshore wind farms through HVDC systems. These rules derived from the combination of grid codes for the integration of offshore wind farms and grid codes for the operation of HVDC transmission systems, connecting power plants...... are available for the grid connection of the offshore wind farms. In this report various transmission systems are presented. Precisely, the HVAC systems, which have dominated up until now in the power transfer sector, are briefly analysed, by providing their advantages, as well as the bottlenecks that occur...

  9. Transient Voltage Stability Analysis and Improvement of A Network with different HVDC Systems

    DEFF Research Database (Denmark)

    Liu, Yan; Chen, Zhe

    2011-01-01

    This paper presents transient voltage stability analysis of an AC system with multi-infeed HVDC links including a traditional LCC HVDC link and a VSC HVDC link. It is found that the voltage supporting capability of the VSC-HVDC link is significantly influenced by the tie-line distance between the...

  10. Application of Grey Wolf Optimizer Algorithm for Optimal Power Flow of Two-Terminal HVDC Transmission System

    Directory of Open Access Journals (Sweden)

    Heba Ahmed Hassan

    2017-01-01

    Full Text Available This paper applies a relatively new optimization method, the Grey Wolf Optimizer (GWO algorithm for Optimal Power Flow (OPF of two-terminal High Voltage Direct Current (HVDC electrical power system. The OPF problem of pure AC power systems considers the minimization of total costs under equality and inequality constraints. Hence, the OPF problem of integrated AC-DC power systems is extended to incorporate HVDC links, while taking into consideration the power transfer control characteristics using a GWO algorithm. This algorithm is inspired by the hunting behavior and social leadership of grey wolves in nature. The proposed algorithm is applied to two different case-studies: the modified 5-bus and WSCC 9-bus test systems. The validity of the proposed algorithm is demonstrated by comparing the obtained results with those reported in literature using other optimization techniques. Analysis of the obtained results show that the proposed GWO algorithm is able to achieve shorter CPU time, as well as minimized total cost when compared with already existing optimization techniques. This conclusion proves the efficiency of the GWO algorithm.

  11. Stabilising system frequency using HVDC between the Continental European, Nordic, and Great Britain systems

    NARCIS (Netherlands)

    de Haan, J.E.S.; Escudero Concha, C.; Gibescu, M.; van Putten, J.; Doorman, G.L.; Kling, W.L.

    2016-01-01

    For future efficiency improvement of the frequency containment process (primary control) within European power systems, cooperation between (multiple) synchronous areas using their controllable HVDC interconnections is optioned. However, the differences in system size, HVDC interconnection capacity,

  12. Economics and a novel voltage conversion technique associated with exporting Wyoming's energy by HVDC transmission

    Science.gov (United States)

    Xu, Kaili

    Wyoming is by far the largest coal producing state in the US, but local utilization is extremely low. As much as 92% of Wyoming's coal is shipped to the other states and is mainly consumed by their electricity producers. Coal accounts for more than 50% of the US electricity generation and is one of the least expensive energy sources. Wyoming could utilize its coal better by exporting electricity instead of exporting the coal only in its raw form. Natural gas is another important energy resource in Wyoming but local utilization is even lower. As a result of the development in coalbed methane fields, natural gas production in Wyoming is almost in pace with its coal production. In addition to constructing more new pipelines, new transmission lines should be considered as an alternative way of exporting this energy. Because of their enormous electricity market sizes and high electricity prices, California, Texas and Illinois are chosen to be the target markets for Wyoming's electricity. The proposed transmission schemes use High Voltage DC (HVDC) lines, which are suitable for long distance and cross-system power transmission. Technical and economic feasibilities are studied in details. The Wyoming-California scheme has a better return of investment than both the Wyoming-Texas and the Wyoming-Illinois schemes. A major drawback of HVDC transmission is the high level of harmonics generated by the converters. Elaborate filtering is required at both the AC and the DC sides. A novel pulse-multiplication method is proposed in the thesis to reduce the harmonics from the converter source. By introducing an averaging inductor, the proposed method uses less thyristors to achieve the same high-pulse operation as the existing series scheme. The reduction of thyristors makes the switching circuit more reliable and easier to control and maintain. Harmonic analysis shows that the harmonic level can be reduced to about one third of the original system. The proposed method is also

  13. Field tests of Sub-Synchronous Oscillation damping and frequency controllers of the Rihand-Delhi HVDC bipole

    Energy Technology Data Exchange (ETDEWEB)

    Prasad, Mata [ABB, New Delhi (India); Rao, L V; Chakravorty, S; Moni, R S; Dass, R [National Thermal Power Corporation Ltd., New Delhi (India); Mishra, R B; Tripathi, D B [Powergrid (India); Bjorklund, Hans; Duchen, Hugo; Westling, Soren [ABB Power Systems, Ludvika (Sweden)

    1994-12-31

    The Rihand-Delhi Hvdc transmission system comprises of two poles in bipolar mode, each of 750 MW nominal capacity. The length of the transmission line is 814 km and the main objective of the link is the transmission of bulk power from the Singrauli/Rihand thermal generating complex to the major load centers near the National Capital region. As in all major Hvdc schemes, the Rihand-Delhi Hvdc project has also been provided with a SSO damping controller which was extensively tested in the simulator prior to installation. This paper describes some of the important field tests conducted to ascertain actual performance and compares the same with corresponding simulator cases. Also covered is the performance of the frequency controller. (author) 3 refs., 9 figs.

  14. Study on the characteristics of multi-infeed HVDC

    Science.gov (United States)

    Li, Ming; Song, Xinli; Liu, Wenzhuo; Xiang, Yinxing; Zhao, Shutao; Su, Zhida; Meng, Hang

    2017-09-01

    China has built more than ten HVDC transmission projects in recent years [1]. Now, east China has formed a multi-HVDC feed pattern grid. It is imminent to study the interaction of the multi-HVDC and the characteristics of it. In this paper, an electromechanical-electromagnetic hybrid model is built with electromechanical data of a certain power network. We use electromagnetic models to simulate the HVDC section and electromechanical models simulate the AC power network [2]. In order to study the characteristics of the grid, this paper adds some faults to the line and analysed the fault characteristics. At last give analysis of the fault characteristics.

  15. Review of the development of multi-terminal HVDC and DC power grid

    Science.gov (United States)

    Chen, Y. X.

    2017-11-01

    Traditional power equipment, power-grid structures, and operation technology are becoming increasingly powerless with the large-scale renewable energy access to the grid. Thus, we must adopt new technologies, new equipment, and new grid structure to satisfy future requirements in energy patterns. Accordingly, the multiterminal direct current (MTDC) transmission system is receiving increasing attention. This paper starts with a brief description of current developments in MTDC worldwide. The MTDC project, which has been placed into practical operation, is introduced by the Italian-Corsica-Sardinian three-terminal high-voltage DC (HVDC) project. We then describe the basic characteristics and regulations of multiterminal DC transmission. The current mainstream of several control methods are described. In the third chapter, the key to the development of MTDC system or hardware and software technology that restricts the development of multiterminal DC transmission is discussed. This chapter focuses on the comparison of double-ended HVDC and multiterminal HVDC in most aspects and subsequently elaborates the key and difficult point of MTDC development. Finally, this paper summarizes the prospect of a DC power grid. In a few decades, China can build a strong cross-strait AC-DC hybrid power grid.

  16. Power for southern Italy: hvdc Sardinia to mainland 200 MW scheme now commissioned

    Energy Technology Data Exchange (ETDEWEB)

    1967-02-16

    Transmission of the maximum rated power of 200 MW over the hvdc system which now links Sardinia with the Italian Mainland marks the successful completion of a notable British Export contract by English Electric. The link was commissioned on February 1. The Sardinia scheme is the seventh hvdc scheme to be completed in the world and is the first to be engineered by submarine cable.

  17. Voltage Stability Bifurcation Analysis for AC/DC Systems with VSC-HVDC

    Directory of Open Access Journals (Sweden)

    Yanfang Wei

    2013-01-01

    Full Text Available A voltage stability bifurcation analysis approach for modeling AC/DC systems with VSC-HVDC is presented. The steady power model and control modes of VSC-HVDC are briefly presented firstly. Based on the steady model of VSC-HVDC, a new improved sequential iterative power flow algorithm is proposed. Then, by use of continuation power flow algorithm with the new sequential method, the voltage stability bifurcation of the system is discussed. The trace of the P-V curves and the computation of the saddle node bifurcation point of the system can be obtained. At last, the modified IEEE test systems are adopted to illustrate the effectiveness of the proposed method.

  18. HVDC keitiklių charakteristikų tyrimas

    OpenAIRE

    Miliauskas, Tadas

    2016-01-01

    Nowadays HVDC technology are rapidly evolving in the world. Number of HVDC interconnectios are constantly growing and a lot of asychonous systems are connected using the HVDC interconnections. There are two HVDC interconnections started working in Lithuania this year: NordBalt – Connection with Sweden and LitPol Link – connection with Poland. In this final project are widely considered LitPol Link system, investigating characteristics of this connection. Using modeling program ...

  19. Controller Architecture Design for MMC-HVDC

    Directory of Open Access Journals (Sweden)

    ZHANG, B.

    2014-05-01

    Full Text Available Compared with high voltage direct current (HVDC, the primary and secondary systems of modular multilevel converter based HVDC (MMC-HVDC are complicated. And the characteristics of the control system determine the properties of the MMC-HVDC system to a certain extent. This paper investigates the design of control architecture. First, the structure and parameters of the 21-level MMC-HVDC are designed. Second, the framework of the control system is studied in details and a complete control system is established. The communication mode and content are built between each layer, and the control system program is developed and debugged. Then The steady state test platform of the sub-module and the relevant control system are designed. Finally, the steady-state tests and the system test of the physical MMC-HVDC simulation system are conducted, which prove that the SMC can control the sub-module (SM efficiently, and the control system could realize efficient start and stop of the physical system. Meanwhile, the capacitor voltage balance between the sub-modules and the basic fault protection and control of the DC voltage and power are verified to be effective.

  20. Negative sequence current control in wind power plants with VSC-HVDC connection

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay; Teodorescu, Remus; Rodriguez, Pedro

    2012-01-01

    Large offshore wind power plants may have multi-MW wind turbine generators (WTG) equipped with full-scale converters (FSC) and voltage source converter (VSC) based high voltaage direct-current (HVDC) transmission for grid connection. The power electronic converters in theWTG-FSC and the VSC......-HVDC allow fast current control in the offshore grid. This paper presents a method of controlling the negative sequence current injection into the offshore grid from the VSC-HVDC as well as WTG-FSCs. This would minimize the power oscillations and hence reduce the dc voltage overshoots in the VSC-HVDC system...... as well as in the WTG-FSCs; especially when the offshore grid is unbalanced due to asymmetric faults. The formulation for negative sequence current injection is mathematically derived and then implemented in electromagnetic transients (EMT) simulation model. The simulated results show that the negative...

  1. Power system analysis of Hanlim superconducting HVDC system using real time digital simulator

    International Nuclear Information System (INIS)

    Won, Y.J.; Kim, J.G.; Kim, A.R.; Kim, G.H.; Park, M.; Yu, I.K.; Sim, K.D.; Cho, J.; Lee, S.; Jeong, K.W.; Watanabe, K.

    2011-01-01

    KEPCO has planned to construct a test site for renewable energy in Jeju power system. One kilometer length of total 8 km was designed as superconducting DC cable. We have developed a simulation model of the 8 km HVDC system using real time digital simulator. The simulation result shows that the HVDC line was not affected by wind power variation. Jeju island is located approximately 100 km south from the mainland of Korea, and had a peak load of about 553 MW in 2008. The demand increases 7.2% a year over the last 5 years. Since the wind profiles of Jeju island are more favorable than mainland of Korea, many companies have shown interest in the wind power business at the Jeju island. Moreover KEPCO has a plan for renewable energy test too whose power will be delivered by HVDC system. One kilometer length of total 8 km was designed as superconducting DC cable. Rest 7 km will be the conventional overhead line. In this paper, the authors have developed a simulation model of the power network around 8 km HVDC system using real time digital simulator (RTDS).

  2. An Assessment of Converter Modelling Needs for Offshore Wind Power Plants Connected via VSC-HVDC Networks

    DEFF Research Database (Denmark)

    Glasdam, Jakob; Zeni, Lorenzo; Hjerrild, Jesper

    2013-01-01

    Modular multilevel cascaded converter (MMCC) based high voltage direct current (HVDC) transmission is technically superior to other technologies, especially in case of connection of offshore wind power plants (OWPPs). Modelling challenges are faced by OWPP developers, who are not acquainted...... with detailed information regarding the internal behaviour of such complex devices. This paper presents an investigation of the modelling requirements of the MMCC HVDC system, based on comparison between simulation results using a detailed HVDC representation in PSCAD/EMTDC and two less detailed models realised...

  3. Determining optimal stations for HVDC terminals; Ermittlung vorteilhafter HGUe-Anschluss knoten

    Energy Technology Data Exchange (ETDEWEB)

    Linnemann, C.; Echternacht, D.; Breuer, C.; Heuberger, D.; Moser, A. [RWTH Aachen (Germany). Inst. fuer Elektrische Anlagen und Energiewirtschaft (IAEW)

    2012-07-01

    Due to a massiv increase in renewable generation capacity the need for grid reinforcements in the European transmission grid is rising significantly. The nuclear phase out in Germany enlarges this effect furthermore. The required transmission capacity can be provided using conventional AC equipment but also the usage of HVDC technology is currently discussed. This paper presents an approach for identifying suitable locations for HVDc terminals. Subsequently the approach is applied to a model of the German transmission network in the year 2022. (orig.)

  4. Coordinated system services from offshore wind power plants connected through HVDC networks

    DEFF Research Database (Denmark)

    Zeni, Lorenzo; Glasdam, Jakob; Hesselbæk, Bo

    2014-01-01

    This paper presents an overview of power system services in networks involving multiple onshore power systems, a voltage sourced converter (VSC) based high voltage direct current (HVDC) offshore network and an offshore wind power plant (OWPP). A comprehensive list of services regarding onshore...... as well as offshore network operation – both AC and DC – will be discussed from a state of the art perspective. Among them, the most interesting have been selected and will be treated in more detail and the main contribution of this paper will be to shed light on the most relevant aspects related...... to their implementation. For example, new findings on onshore AC voltage control are reported, that help the characterisation of potential AC voltage control that a VSC-HVDC station may offer to an onshore AC grid. The HVDC system behind the VSC-HVDC station may connect, through other converters, to another AC power...

  5. Application of VSC-HVDC with Shunt Connected SMES for Compensation of Power Fluctuation

    Science.gov (United States)

    Linn, Zarchi; Kakigano, Hiroaki; Miura, Yushi; Ise, Toshifumi

    This paper describes the application of VSC-HVDC (High Voltage DC Transmission using Voltage Source Converter) with shunt connected SMES (Superconducting Magnetic Energy Storage) for compensation of power fluctuation caused by fluctuating power source such as photovoltaics and wind turbines. The objectives of this proposed system is to smooth out fluctuating power in one terminal side of HVDC in order to avoid causing power system instability and frequency deviation by absorbing or providing power according to the system requirement while another terminal side power is fluctuated. The shunt connected SMES charges and discharges the energy to and from the dc side and it compensates required power of fluctuation to obtain constant power flow in one terminal side of VSC-HVDC system. This system configuration has ability for power system stabilization in the case of power fluctuation from natural energy source. PSCAD/EMTDC simulation is used to evaluate the performance of applied system configuration and control method.

  6. Frequency Regulation Strategies in Grid Integrated Offshore Wind Turbines via VSC-HVDC Technology: A Review

    Directory of Open Access Journals (Sweden)

    Jafar Jallad

    2017-08-01

    Full Text Available The inclusion of wind energy in a power system network is currently seeing a significant increase. However, this inclusion has resulted in degradation of the inertia response, which in turn seriously affects the stability of the power system’s frequency. This problem can be solved by using an active power reserve to stabilize the frequency within an allowable limit in the event of a sudden load increment or the loss of generators. Active power reserves can be utilized via three approaches: (1 de-loading method (pitching or over-speeding by a variable speed wind turbine (VSWT; (2 stored energy in the capacitors of voltage source converter-high voltage direct current (VSC-HVDC transmission; and (3 coordination of frequency regulation between the offshore wind farms and the VSC-HVDC transmission. This paper reviews the solutions that can be used to overcome problems related to the frequency stability of grid- integrated offshore wind turbines. It also details the permanent magnet synchronous generator (PMSG with full-scale back to back (B2B converters, its corresponding control strategies, and a typical VSC-HVDC system with an associated control system. The control methods, both on the levels of a wind turbine and the VSC-HVDC system that participate in a system’s primary frequency control and emulation inertia, are discussed.

  7. Mitigation of commutation failures in LCC–HVDC systems based on superconducting fault current limiters

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong-Geon; Khan, Umer Amir; Lee, Ho-Yun; Lim, Sung-Woo; Lee, Bang-Wook, E-mail: bangwook@hanyang.ac.kr

    2016-11-15

    Commutation failure in line commutated converter based HVDC systems cause severe damages on the entire power grid system. For LCC–HVDC, thyristor valves are turned on by a firing signal but turn off control is governed by the external applied AC voltage from surrounding network. When the fault occurs in AC system, turn-off control of thyristor valves is unavailable due to the voltage collapse of point of common coupling (PCC), which causes the commutation failure in LCC–HVDC link. Due to the commutation failure, the power transfer interruption, dc voltage drop and severe voltage fluctuation in the AC system could be occurred. In a severe situation, it might cause the protection system to block the valves. In this paper, as a solution to prevent the voltage collapse on PCC and to limit the fault current, the application study of resistive superconducting fault current limiter (SFCL) on LCC–HVDC grid system was performed with mathematical and simulation analyses. The simulation model was designed by Matlab/Simulink considering Haenam-Jeju HVDC power grid in Korea which includes conventional AC system and onshore wind farm and resistive SFCL model. From the result, it was observed that the application of SFCL on LCC–HVDC system is an effective solution to mitigate the commutation failure. And then the process to determine optimum quench resistance of SFCL which enables the recovery of commutation failure was deeply investigated.

  8. Mitigation of commutation failures in LCC–HVDC systems based on superconducting fault current limiters

    International Nuclear Information System (INIS)

    Lee, Jong-Geon; Khan, Umer Amir; Lee, Ho-Yun; Lim, Sung-Woo; Lee, Bang-Wook

    2016-01-01

    Commutation failure in line commutated converter based HVDC systems cause severe damages on the entire power grid system. For LCC–HVDC, thyristor valves are turned on by a firing signal but turn off control is governed by the external applied AC voltage from surrounding network. When the fault occurs in AC system, turn-off control of thyristor valves is unavailable due to the voltage collapse of point of common coupling (PCC), which causes the commutation failure in LCC–HVDC link. Due to the commutation failure, the power transfer interruption, dc voltage drop and severe voltage fluctuation in the AC system could be occurred. In a severe situation, it might cause the protection system to block the valves. In this paper, as a solution to prevent the voltage collapse on PCC and to limit the fault current, the application study of resistive superconducting fault current limiter (SFCL) on LCC–HVDC grid system was performed with mathematical and simulation analyses. The simulation model was designed by Matlab/Simulink considering Haenam-Jeju HVDC power grid in Korea which includes conventional AC system and onshore wind farm and resistive SFCL model. From the result, it was observed that the application of SFCL on LCC–HVDC system is an effective solution to mitigate the commutation failure. And then the process to determine optimum quench resistance of SFCL which enables the recovery of commutation failure was deeply investigated.

  9. Mitigation of commutation failures in LCC-HVDC systems based on superconducting fault current limiters

    Science.gov (United States)

    Lee, Jong-Geon; Khan, Umer Amir; Lee, Ho-Yun; Lim, Sung-Woo; Lee, Bang-Wook

    2016-11-01

    Commutation failure in line commutated converter based HVDC systems cause severe damages on the entire power grid system. For LCC-HVDC, thyristor valves are turned on by a firing signal but turn off control is governed by the external applied AC voltage from surrounding network. When the fault occurs in AC system, turn-off control of thyristor valves is unavailable due to the voltage collapse of point of common coupling (PCC), which causes the commutation failure in LCC-HVDC link. Due to the commutation failure, the power transfer interruption, dc voltage drop and severe voltage fluctuation in the AC system could be occurred. In a severe situation, it might cause the protection system to block the valves. In this paper, as a solution to prevent the voltage collapse on PCC and to limit the fault current, the application study of resistive superconducting fault current limiter (SFCL) on LCC-HVDC grid system was performed with mathematical and simulation analyses. The simulation model was designed by Matlab/Simulink considering Haenam-Jeju HVDC power grid in Korea which includes conventional AC system and onshore wind farm and resistive SFCL model. From the result, it was observed that the application of SFCL on LCC-HVDC system is an effective solution to mitigate the commutation failure. And then the process to determine optimum quench resistance of SFCL which enables the recovery of commutation failure was deeply investigated.

  10. Stability of DC Voltage Droop Controllers in VSC HVDC Systems

    DEFF Research Database (Denmark)

    Thams, Florian; Suul, Jon Are; D’Arco, Salvatore

    2015-01-01

    Future multi-terminal HVDC systems are expected to utilize dc voltage droop controllers and several control implementations have been proposed in literature. This paper first classifies possible dc droop implementations in a simple framework. Then, the small-signal stability of a VSC-based conver......Future multi-terminal HVDC systems are expected to utilize dc voltage droop controllers and several control implementations have been proposed in literature. This paper first classifies possible dc droop implementations in a simple framework. Then, the small-signal stability of a VSC...

  11. Study on emergency power control strategy for AC/DC hybrid power system containing VSC-HVDC

    Science.gov (United States)

    Liu, Lin; Hu, Zhenda; Ye, Rong; Lin, Zhangsui; Yang, Xiaodong; Yi, Yang

    2018-04-01

    This paper presents a comprehensive emergency power control strategy for AC/DC hybrid power systems containing VSC-HVDC. Firstly, the paper analyzes the power support of the VSC-HVDC to the AC lines using the Power Transferring Relativity Factor (PTRF). Then the power adjustment of the VSC-HVDC in several different circumstances are calculated. Finally, the online power control strategies of VSC-HVDC are designed, which could rapidly control the power of the VSC-HVDC, keeping the power flow of AC lines below the upper limit. Furthermore, the strategy is proven to be effective by the simulations with EMTDC/PSCAD.

  12. Impact of Offshore Wind Power Integrated by VSC-HVDC on Power Angle Stability of Power Systems

    Science.gov (United States)

    Lu, Haiyang; Tang, Xisheng

    2017-05-01

    Offshore wind farm connected to grid by VSC-HVDC loses frequency support for power system, so adding frequency control in wind farm and VSC-HVDC system is an effective measure, but it will change wind farm VSC-HVDC’s transient stability on power system. Through theoretical analysis, concluding the relationship between equivalent mechanical power and electromagnetic power of two-machine system with the active power of wind farm VSC-HVDC, then analyzing the impact of wind farm VSC-HVDC with or without frequency control and different frequency control parameters on angle stability of synchronous machine by EEAC. The validity of theoretical analysis has been demonstrated through simulation in PSCAD/EMTDC.

  13. HVDC Ground Electrodes - a Source of Geophysical Data

    Science.gov (United States)

    Freire, P. F.; Pereira, S. Y.

    2015-12-01

    The HVDC electrode is a component of a High Voltage Direct Current energy transmission system, and is designed to inject into the ground continuous currents up to 3500 A. The typical HVDC ground electrode is a ring of vertical conductors, 1 km wide, buried a few tens of meters.The design of a HVDC electrode is based on extensive geological, geotechnical and geophysical surveys. Geophysical data are usually electrical (VES) and electromagnetic (TEM/MT) acquisitions, for the modeling of the shallow, near-surface and deep layers of the crust. This survey aims, first, the electrode site selection, and then, at the selected site, this data is combined into a single apparent resistivity curve, which is inverted, allowing for the determination of the layered geoelectric crust model. The injection of electrical continuous current in the electrode is then simulated, with the geoelectric crust model, for the determination of the soil surface potential profile (which is usually asymmetric for different directions, due to non-1D geoelectric models).For the commissioning of a HVDC electrode, field measurements are done, such as electrode grounding resistance, soil surface potentials and metal-to-soil potentials at specific structures (buried pipelines, for instance).The geophysical data acquired during the design phase is a set of data completely independent from the electrical data acquired during the electrode commissioning phase, and both are correlated by the geoelectric model. It happens, therefore, that the geoelectric model can be calibrated based on the electrical data, with the correction of static shifts and other adjustments.This paper suggests that the commissioning of HVDC systems should be associated to a research & development program, with a university or foundation. The idea is to enjoy the opportunity of a more complete field survey, with the acquisition of a wide set of data for a better geological characterization of the area where the electrode was built.

  14. Offshore Transmission Technology

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-10-15

    The purpose of this document is to give an overview of offshore electricity transmission technologies. In particular this document is concerned with the use of High Voltage Direct Current (HVDC) systems and more specifically with the development of Voltage Source Converter (VSC) technology. This report outlines the current state of the main technology groups required for offshore HVDC transmission as well as giving examples of offshore projects (both current and future). Finally some indications of likely unit costs for HV assets are given.

  15. An Annotated Bibliography of HVDC Transmission and FACTS Devices, 1996-1997.

    Energy Technology Data Exchange (ETDEWEB)

    Litzenberger, Wayne H.; Varma, Rajiv K.; Flanagan, John D. [eds.

    1998-06-01

    This edition of the Annotated Bibliography of HVDC Transmission and FACTS Devices continues work begun in 1962 by the late Erik Bromberg, Bonneville Power Administration Librarian. His original bibliography covered the period 1932--1962. Subsequent editions were compiled by Bromberg, Val S. Lava, and Wayne Litzenberger, all of Bonneville Power Administration. Beginning with the 1991--1993 edition, the scope of the bibliography was expanded to include flexible ac transmission (FACTS) devices. This 1996--1997 edition also contains information for 1998. Preparation of the present edition took place primarily in May-June of 1998. All pertinent references have been included that were available to the editors at the time of preparation. Papers for the 1998 IEEE Winter and Summer Power Meetings and 1998 T and D Conference have been included. This edition contains the organizational affiliation of the first-named author as an aid to accessing the reference. Unfortunately, space limitations prevented the inclusion of the affiliations of all authors. Some minor editorial changes have been made to abstracts to ensure consistency in style and syntax.

  16. Enhanced Dynamic Voltage Stability Support by VSC-HVDC for Offshore Wind Applications using Trajectory Sensitivity Analysis

    DEFF Research Database (Denmark)

    Liu, Hongzhi; Chen, Zhe; Liu, Leo

    2013-01-01

    The integration of large-scale wind power plants changes the structure, configuration and operation of conventional power systems and brings challenges to the security and stability of power systems. Dynamic voltage stability of power systems with high wind penetration is one of the critical issues....... In this paper, VSC-HVDC transmission system is used to integrate a large-scale wind power plant into the onshore power grid. For different voltage support strategies of VSC-HVDC, a trajectory sensitivity analysisbased approach is proposed to find the minimum onshore VSC capacity with which the VSC-HVDC can...... provide enough support for the improvement of system voltage stability after a disturbance. Sensitivities of reactive power output of VSC to its capacity increase are calculated instead of the sensitivities of bus voltage magnitude towards the reactive power injection variation of VSC. Simulation results...

  17. Investigating the impact of unanticipated market and construction delays on the development of a meshed HVDC grid using dynamic transmission planning

    NARCIS (Netherlands)

    Shariat Torbaghan, S.; Gibescu, M.; Rawn, B.G.; Müller, H.; Roggenkamp, M.; vd Meijden, M.A.M.M.

    2015-01-01

    This study presents a market-based dynamic transmission planning framework for the construction of a meshed offshore voltage source converter-high voltage direct current (VSC-HVDC) grid. Such a grid is foreseen for integrating offshore wind and electricity trade functions among the North Sea

  18. An Annotated Bibliography of High-Voltage Direct-Current Transmission and Flexible AC Transmission (FACTS) Devices, 1991-1993.

    Energy Technology Data Exchange (ETDEWEB)

    Litzenberger, Wayne; Lava, Val

    1994-08-01

    References are contained for HVDC systems, converter stations and components, overhead transmission lines, cable transmission, system design and operations, simulation of high voltage direct current systems, high-voltage direct current installations, and flexible AC transmission system (FACTS).

  19. Modelling and Simulation of VSC-HVDC Connection for Offshore Wind Power Plants

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay Kumar; Teodorescu, Remus; Rodriguez, Pedro

    2010-01-01

    Several large offshore wind power plants (WPP) are planned in the seas around Europe. VSC-HVDC is a suitable means of integrating such large and distant offshore WPP which need long submarine cable transmission to the onshore grid. Recent trend is to use large wind turbine generators with full...... scale converters to achieve an optimal operation over a wide speed range. The offshore grid then becomes very much different from the conventional power system grid, in the sense that it is connected to power electronic converters only. A model of the wind power plant with VSC-HVDC connection...

  20. An improved droop control method for multi-terminal VSC-HVDC converter stations

    DEFF Research Database (Denmark)

    Wang, Hao; Wang, Yue; Duan, Guozhao

    2017-01-01

    Multi-terminal high voltage direct current transmission based on voltage source converter (VSC-HVDC) grids can connect non-synchronous alternating current (AC) grids to a hybrid alternating current and direct current (AC/DC) power system, which is one of the key technologies in the construction...

  1. Discrete-Time Nonlinear Control of VSC-HVDC System

    Directory of Open Access Journals (Sweden)

    TianTian Qian

    2015-01-01

    Full Text Available Because VSC-HVDC is a kind of strong nonlinear, coupling, and multi-input multioutput (MIMO system, its control problem is always attracting much attention from scholars. And a lot of papers have done research on its control strategy in the continuous-time domain. But the control system is implemented through the computer discrete sampling in practical engineering. It is necessary to study the mathematical model and control algorithm in the discrete-time domain. The discrete mathematical model based on output feedback linearization and discrete sliding mode control algorithm is proposed in this paper. And to ensure the effectiveness of the control system in the quasi sliding mode state, the fast output sampling method is used in the output feedback. The results from simulation experiment in MATLAB/SIMULINK prove that the proposed discrete control algorithm can make the VSC-HVDC system have good static, dynamic, and robust characteristics in discrete-time domain.

  2. Comparison of PI and PR current controllers applied on two-level VSC-HVDC transmission system

    DEFF Research Database (Denmark)

    Manoloiu, A.; Pereria, H.A.; Teodorescu, Remus

    2015-01-01

    This paper analyzes differences between αβ and dq reference frames regarding the control of two-level VSC-HVDC current loop and dc-link voltage outer loop. In the first part, voltage feedforward effect is considered with PI and PR controllers. In the second part, the feedforward effect is removed...... and the PR gains are tuned to keep the dynamic performance. Also, the power feedforward is removed and the outer loop PI controller is tuned in order to maintain the system dynamic performance. The paper is completed with simulation results, which highlight the advantages of using PR controller....

  3. Site Selection for Hvdc Ground Electrodes

    Science.gov (United States)

    Freire, P. F.; Pereira, S. Y.

    2014-12-01

    High-Voltage Direct Current (HVDC) transmission systems are composed of a bipole transmission line with a converter substation at each end. Each substation may be equipped with a HVDC ground electrode, which is a wide area (up to 1 km Ø) and deep (from 3 to 100m) electrical grounding. When in normal operation, the ground electrode will dissipate in the soil the unbalance of the bipole (~1.5% of the rated current). When in monopolar operation with ground return, the HVDC electrode will inject in the soil the nominal pole continuous current, of about 2000 to 3000 Amperes, continuously for a period up to a few hours. HVDC ground electrodes site selection is a work based on extensive geophysical and geological surveys, in order to attend the desired design requirements established for the electrodes, considering both its operational conditions (maximum soil temperature, working life, local soil voltage gradients etc.) and the interference effects on the installations located up to 50 km away. This poster presents the geophysical investigations conducted primarily for the electrodes site selection, and subsequently for the development of the crust resistivity model, which will be used for the interference studies. A preliminary site selection is conducted, based on general geographical and geological criteria. Subsequently, the geology of each chosen area is surveyed in detail, by means of electromagnetic/electrical geophysical techniques, such as magnetotelluric (deep), TDEM (near-surface) and electroresistivity (shallow). Other complementary geologic and geotechnical surveys are conducted, such as wells drilling (for geotechnical characterization, measurement of the water table depth and water flow, and electromagnetic profiling), and soil and water sampling (for measurement of thermal parameters and evaluation of electrosmosis risk). The site evaluation is a dynamic process along the surveys, and some sites will be discarded. For the two or three final sites, the

  4. DC breakdown characteristics of silicone polymer composites for HVDC insulator applications

    Science.gov (United States)

    Han, Byung-Jo; Seo, In-Jin; Seong, Jae-Kyu; Hwang, Young-Ho; Yang, Hai-Won

    2015-11-01

    Critical components for HVDC transmission systems are polymer insulators, which have stricter requirements that are more difficult to achieve compared to those of HVAC insulators. In this study, we investigated the optimal design of HVDC polymer insulators by using a DC electric field analysis and experiments. The physical properties of the polymer specimens were analyzed to develop an optimal HVDC polymer material, and four polymer specimens were prepared for DC breakdown experiments. Single and reverse polarity breakdown tests were conducted to analyze the effect of temperature on the breakdown strength of the polymer. In addition, electric fields were analyzed via simulations, in which a small-scale polymer insulator model was applied to prevent dielectric breakdown due to electric field concentration, with four DC operating conditions taken into consideration. The experimental results show that the electrical breakdown strength and the electric field distribution exhibit significant differences in relation to different DC polarity transition procedures.

  5. Integration of power flow controlling devices and HVDC-systems into the optimal power flow; Integration von leistungsflusssteuernden Komponenten und HGUe-Systemen in die Leistungsflussoptimierung

    Energy Technology Data Exchange (ETDEWEB)

    Natemeyer, Hendrik; Scheufen, Martin; Roehder, Andreas; Schnettler, Armin [RWTH Aachen Univ. (Germany). Inst. fuer Hochspannungstechnik (IFHT)

    2012-07-01

    An integration of High Voltage Direct Current Transmission Systems (HVDC) or Flexible AC Transmission Systems (FACTS) into power systems enables the possibility to actively influence and control the corresponding power flows in the electrical network. The systemic benefits are a more efficient utilization of existing transmission capacities and improved controllability in fault situations. This paper introduces methods of a coordinative control of such devices and their representation in stationary power flow calculations including the control in (n-1)-cases. This might be a useful tool for the network operation, especially in face of more frequently occurring fast system changes. Examples of a corresponding implementation and application are provided. (orig.)

  6. Cooperative control scheme for an HVDC system connected to an isolated BWR nuclear power plant

    International Nuclear Information System (INIS)

    Sakurai, T.; Goto, K.; Kawai, T.; Matori, I.; Nakao, T.; Watanabe, A.

    1983-01-01

    This paper describes a cooperative control system to achieve stable operation of an isolated BWR nuclear plant linked to an HVDC system. In the proposed control system, under normal conditions the power plant is controlled according to the generating power reference and the generator frequency deviation is adjusted by converter power control. Such frequency control is also effective in the case of AC-DC system faults. In addition to the frequency control, an overload control is provided with the HVDC system, where the DC transmission power in the sound poles is increased due to a fault detection signal from the faulty pole. Effects of the above mentioned control systems were studied using digital dynamic programs. The sets of simulation results confirmed that in the case of a DC single pole fault, the plant is able to continue operation without any use of the turbine speed control units even for a restarting failure in the faulty pole. In case of a DC two pole fault, the plant is able to continue operation, being assisted by turbine speed control units when restarting in the faulty poles succeeds. In case of an AC three-line to ground fault near the AC terminal of the converter at the sending or receiving end, the system is able to continue stable operation, being supplemented by the turbine control unit when the faulty section of the AC system is isolated by a main or back-up relaying system

  7. Impact of Cyber Attacks on High Voltage DC Transmission Damping Control

    Directory of Open Access Journals (Sweden)

    Rui Fan

    2018-04-01

    Full Text Available Hybrid AC/HVDC (AC-HVDC grids have evolved to become huge cyber-physical systems that are vulnerable to cyber attacks because of the wide attack surface and increasing dependence on intelligent electronic devices, computing resources and communication networks. This paper, for the first time, studies the impact of cyber attacks on HVDC transmission oscillation damping control.Three kinds of cyber attack models are considered: timing attack, replay attack and false data injection attack. Followed by a brief introduction of the HVDC model and conventional oscillation damping control method, the design of three attack models is described in the paper. These attacks are tested on a modified IEEE New England 39-Bus AC-HVDC system. Simulation results have shown that all three kinds of attacks are capable of driving the AC-HVDC system into large oscillations or even unstable conditions.

  8. A novel modular multilevel converter modelling technique based on semi-analytical models for HVDC application

    Directory of Open Access Journals (Sweden)

    Ahmed Zama

    2016-12-01

    Full Text Available Thanks to scalability, performance and efficiency, the Modular Multilevel Converter (MMC, since its invention, becomes an attractive topology in industrial applications such as high voltage direct current (HVDC transmission system. However, modelling challenges related to the high number of switching elements in the MMC are highlighted when such systems are integrated into large simulated networks for stability or protection algorithms testing. In this work, a novel dynamic models for MMC is proposed. The proposed models are intended to simplify modeling challenges related to the high number of switching elements in the MMC. The models can be easily used to simulate the converter for stability analysis or protection algorithms for HVDC grids.

  9. The Detection of Subsynchronous Oscillation in HVDC Based on the Stochastic Subspace Identification Method

    Directory of Open Access Journals (Sweden)

    Chen Shi

    2014-01-01

    Full Text Available Subsynchronous oscillation (SSO usually caused by series compensation, power system stabilizer (PSS, high voltage direct current transmission (HVDC and other power electronic equipment, which will affect the safe operation of generator shafting even the system. It is very important to identify the modal parameters of SSO to take effective control strategies as well. Since the identification accuracy of traditional methods are not high enough, the stochastic subspace identification (SSI method is proposed to improve the identification accuracy of subsynchronous oscillation modal. The stochastic subspace identification method was compared with the other two methods on subsynchronous oscillation IEEE benchmark model and Xiang-Shang HVDC system model, the simulation results show that the stochastic subspace identification method has the advantages of high identification precision, high operation efficiency and strong ability of anti-noise.

  10. Wide-Area Robust Decentralized Coordinated Control of HVDC Power System Based on Polytopic System Theory

    Directory of Open Access Journals (Sweden)

    Shiyun Xu

    2015-01-01

    Full Text Available The present study proposes a hierarchical wide-area decentralized coordinated control framework for HVDC power system that is robust to multiple operating conditions. The upper level wide-area coordinated controller is designed in the form of dynamic output feedback control that coordinates the lower level HVDC supplementary controller, PSS, and SVC. In order to enhance the robustness of the designed controller under various operating conditions, the polytopic model is introduced such that the closed-loop control system can be operated under strong damping mode in virtue of the stability criterion based on damping ratio. Simulation results demonstrate that the proposed controller design algorithm is capable of enhancing the system damping over four different conditions.

  11. Power system analysis of Hanlim superconducting HVDC system using real time digital simulator

    Science.gov (United States)

    Won, Y. J.; Kim, J. G.; Kim, A. R.; Kim, G. H.; Park, M.; Yu, I. K.; Sim, K. D.; Cho, J.; Lee, S.; Jeong, K. W.; Watanabe, K.

    2011-11-01

    Jeju island is located approximately 100 km south from the mainland of Korea, and had a peak load of about 553 MW in 2008. The demand increases 7.2% a year over the last 5 years. Since the wind profiles of Jeju island are more favorable than mainland of Korea, many companies have shown interest in the wind power business at the Jeju island. Moreover KEPCO has a plan for renewable energy test too whose power will be delivered by HVDC system. One kilometer length of total 8 km was designed as superconducting DC cable. Rest 7 km will be the conventional overhead line. In this paper, the authors have developed a simulation model of the power network around 8 km HVDC system using real time digital simulator (RTDS).

  12. A Novel Topology of Hybrid HVDC Circuit Breaker for VSC-HVDC Application

    Directory of Open Access Journals (Sweden)

    Van-Vinh Nguyen

    2017-10-01

    Full Text Available The use of high voltage direct current (HVDC circuit breakers (CBs with the capabilities of bidirectional fault interruption, reclosing, and rebreaking can improve the reliable and safe operation of HVDC grids. Although several topologies of CBs have been proposed to perform these capabilities, the limitation of these topologies is either high on-state losses or long time interruption in the case bidirectional fault current interruption. Long time interruption results in the large magnitude of the fault current in the voltage source converter based HVDC (VSC-HVDC system due to the high rate of rise of fault current. This paper proposes a new topology of hybrid CB (HCB with lower conduction loss and lower interruption time to solve the problems. The proposed topology is based on the inverse current injection method, which uses the capacitor to enforce the fault current to zero. In the case of the bidirectional fault current interruption, the capacitor does not change its polarity after identifying the direction of fault current, which can reduce the interruption time accordingly. A switching control algorithm for the proposed topology is presented in detail. Different operation modes of proposed HCB, such as normal current mode, breaking fault current mode, discharging, and reversing capacitor voltage modes after clearing the fault, are considered in the proposed algorithm. The proposed topology with the switching control algorithm is tested in a simulation-based system. Different simulation scenarios such as temporary and permanent faults are carried out to verify the performance of the proposed topology. The simulation is performed in the Matlab/Simulink environment.

  13. Effects of HVDC on power systems small signal angle stability

    Energy Technology Data Exchange (ETDEWEB)

    Custodio, D.T.; Paccini, R.O.; Kopcak, I.; Costa, V.F. da [State University of Campinas (UNICAMP), SP (Brazil). School of Electrical and Computer Engineering. Power Systems Dept.], Emails: totti@dsee.fee.unicamp.br, rodrigo@dsee.fee.unicamp.br, kopcak@dsee.fee.unicamp.br, vivaldo@dsee.fee.unicamp.br

    2009-07-01

    In this paper, a didactic method for parameters tuning of the Power Oscillation Damper (POD) coupled to the HVDC constant current controller is proposed utilizing the MATLAB package with a control system toolbox. First, modal analysis is done from the system state matrix to determine the critical mode and oscillation natural frequency. Input and output linearized matrixes are built to single-input and single-output (SISO) control systems. The phase to be compensated between the active power flow in the parallel AC inter-tie and the current reference signal of the HVDC constant current controller is obtained from the Nyquist theorem. Following, the POD time constants are obtained. Finally, the static gain of the POD is tuned based on the root locus method of the classical control theory. Simulations results prove that the DC power modulation is efficient to damp the AC power oscillations. This method is straightforward because only involves matrix operation. (author)

  14. Large-scale wind energy application. Transporting wind energy over long distances using an HVDC transmission line, in combination with hydro energy or biomass energy

    International Nuclear Information System (INIS)

    Coelingh, J.P.; Van Wijk, A.J.M.; Betcke, J.W.H.; Geuzendam, C.; Gilijamse, W.; Westra, C.A.; Curvers, A.P.W.M.; Beurskens, H.J.M.

    1995-08-01

    The main objective of the study on the title subject is to assess the long-term prospects for large-scale application of wind energy, in combination with hydro energy in Norway and in combination with biomass energy in Scotland. These countries have high wind resource areas, however they are located far away from load centres. The development of new transmission technologies as High Voltage Direct Current (HVDC) transmission lines, in combination with highly suitable places for wind energy in Norway and Scotland, forms the driving force behind this study. The following two cases are being considered: (1) a large-scale wind farm (1,000 MW) in Norway from which electricity is transmitted to The Netherlands by using an HVDC transmission line, in combination with hydro energy. Hydro energy already makes a large contribution to the energy supply of Norway. Wind farms can contribute to the electricity production and save hydro energy generated electricity and make the export of electricity profitable; and (2) a large-scale wind farm (1,000 MW) in Scotland from which electricity is transmitted to The Netherlands by using an HVDC transmission line, in combination with biomass energy. Scotland has a large potential for biomass production such as energy crops and forestry. Poplars and willows cultivated on set-aside land can be gasified and fed into modern combined-cycle plants to generate electricity. In Scotland the usable potential of wind energy may be limited in the short and medium term by the capacity of the grid. New connections can overcome this constraint and allow wind energy to be treated as a European Union resource rather than as a national resource. Thus, the concept of this study is to look at the possibilities of making a 1,000 MW link from The Netherlands to Norway or to Scotland, in order to supply electricity at competitive costs generated with renewable energy sources. 16 figs., 24 tabs., 80 refs

  15. Implementation of the production management of a HVDC overlaydistribution system in the load frequency control of a three-phase-current combined systems; Integration der Betriebsfuehrung eines HGUe-Overlay-Netzes in die Leistungs-Frequenz-Regelung eines Drehstrom-Verbundnetzes

    Energy Technology Data Exchange (ETDEWEB)

    Marten, Anne-Katrin

    2012-07-01

    To reduce emission of carbon dioxide the proportion of renewable energies is rapidly growing in German and European grids in general. Additionally, the bulk of them are generated in only a few spots in European transmission grid, whereas conventional power plants will shut down and the load center distribution will still be decentralized. This results in the need of a new and powerful transmission grid, which is able to transport bulk power over long distances. To overcome this challenge one of the discussed solutions for Europe is an Overlay Network based on HVDC technology connecting spots of bulk renewable energy plants and important load centers. Because of different performance compared to an ac grid, it is necessary for an HVDC Overlay Network to actively sustain system services such as power frequency control to ensure system stability and power quality as well as the ac grid does. A novel method for realizing participation of a HVDC Overlay Network in power frequency control is presented. It hasn't only an advantage for load frequency power flows, but also for contracted balancing power flows which are also feed via the dc grid pro rata. Numerical case studies are made to show some benefits of this method in case of various disturbances. It is shown that a HVDC Overlay Network with the developed operating control releases the ac grid by an adjustable amount of power flows and improves the power frequency control for example in terms of promptness and lower frequency deviations.

  16. Direct current power delivery system and method

    Science.gov (United States)

    Zhang, Di; Garces, Luis Jose; Dai, Jian; Lai, Rixin

    2016-09-06

    A power transmission system includes a first unit for carrying out the steps of receiving high voltage direct current (HVDC) power from an HVDC power line, generating an alternating current (AC) component indicative of a status of the first unit, and adding the AC component to the HVDC power line. Further, the power transmission system includes a second unit for carrying out the steps of generating a direct current (DC) voltage to transfer the HVDC power on the HVDC power line, wherein the HVDC power line is coupled between the first unit and the second unit, detecting a presence or an absence of the added AC component in the HVDC power line, and determining the status of the first unit based on the added AC component.

  17. Investigation of Hybrid Pseudo Bipolar HVDC Performances Supply Power to Passive AC Network

    Directory of Open Access Journals (Sweden)

    Kuan Li

    2014-07-01

    Full Text Available The traditional HVDC plays an important role in the development of power grid. But the traditional HVDC cannot supply power either to entirely passive AC network or to weak AC system. In fact, an entirely passive AC network can be effectively powered through VSC-HVDC. However, the cost of investment in VSC-HVDC is amazingly high due to the limitation of power electronics technology. Based on CSC and VSC, this paper proposes a method to build Hybrid HVDC, which makes the power supply to the passive AC network come true and, at the same time, lowers the investment cost. The effect of topology, steady mathematical model, startup characteristic, steady and transient characteristics in Hybrid HVDC system are systematically studied in this paper. The simulation result shows that Hybrid HVDC can supply power to the passive AC network with high stability. This study provides a theoretical basis for the further development of HVDC.

  18. Impacts of large-scale offshore wind farm integration on power systems through VSC-HVDC

    DEFF Research Database (Denmark)

    Liu, Hongzhi; Chen, Zhe

    2013-01-01

    The potential of offshore wind energy has been commonly recognized and explored globally. Many countries have implemented and planned offshore wind farms to meet their increasing electricity demands and public environmental appeals, especially in Europe. With relatively less space limitation......, an offshore wind farm could have a capacity rating to hundreds of MWs or even GWs that is large enough to compete with conventional power plants. Thus the impacts of a large offshore wind farm on power system operation and security should be thoroughly studied and understood. This paper investigates...... the impacts of integrating a large-scale offshore wind farm into the transmission system of a power grid through VSC-HVDC connection. The concerns are focused on steady-state voltage stability, dynamic voltage stability and transient angle stability. Simulation results based on an exemplary power system...

  19. Definition and Classification of Terms for HVDC Networks

    DEFF Research Database (Denmark)

    Vrana, Til Kristian; Bell, Keith; Sørensen, Poul Ejnar

    2015-01-01

    A systematic terminology for the field of HVDC networks has been developed, closing the gap between the well-established terminologies from AC power systems and HVDC technology. The most relevant items, topologies and concepts have been given clear and unique defined names, and these have been cl...

  20. Harmonic Resonance in Power Transmission Systems due to the Addition of Shunt Capacitors

    Science.gov (United States)

    Patil, Hardik U.

    Shunt capacitors are often added in transmission networks at suitable locations to improve the voltage profile. In this thesis, the transmission system in Arizona is considered as a test bed. Many shunt capacitors already exist in the Arizona transmission system and more are planned to be added. Addition of these shunt capacitors may create resonance conditions in response to harmonic voltages and currents. Such resonance, if it occurs, may create problematic issues in the system. It is main objective of this thesis to identify potential problematic effects that could occur after placing new shunt capacitors at selected buses in the Arizona network. Part of the objective is to create a systematic plan for avoidance of resonance issues. For this study, a method of capacitance scan is proposed. The bus admittance matrix is used as a model of the networked transmission system. The calculations on the admittance matrix were done using Matlab. The test bed is the actual transmission system in Arizona; however, for proprietary reasons, bus names are masked in the thesis copy intended for the public domain. The admittance matrix was obtained from data using the PowerWorld Simulator after equivalencing the 2016 summer peak load (planning case). The full Western Electricity Coordinating Council (WECC) system data were used. The equivalencing procedure retains only the Arizona portion of the WECC. The capacitor scan results for single capacitor placement and multiple capacitor placement cases are presented. Problematic cases are identified in the form of 'forbidden response. The harmonic voltage impact of known sources of harmonics, mainly large scale HVDC sources, is also presented. Specific key results for the study indicated include: (1) The forbidden zones obtained as per the IEEE 519 standard indicates the bus 10 to be the most problematic bus. (2) The forbidden zones also indicate that switching values for the switched shunt capacitor (if used) at bus 3 should be

  1. Advanced hybrid transient stability and EMT simulation for VSC-HVDC systems

    NARCIS (Netherlands)

    Van Der Meer, A.A.; Gibescu, M.; Van Der Meijden, M.A.M.M.; Kling, W.L.; Ferreira, J.A.

    2015-01-01

    This paper deals with advanced hybrid transient stability and electromagnetic-transient (EMT) simulation of combined ac/dc power systems containing large amounts of renewable energy sources interfaced through voltage-source converter-high-voltage direct current (VSC-HVDC). The concerning transient

  2. Control of a hybrid HVDC link to increase inter-regional power transfer

    DEFF Research Database (Denmark)

    Kotb, Omar; Ghandhari, Mehrdad; Eriksson, Robert

    2016-01-01

    This paper examines the application of a hybrid HVDC link in a two area power system with the purpose of increasing the inter-regional power transfer. A hybrid HVDC system combines both LCCs and VSCs, and hence it is capable of combining the benefits of both converter technologies, such as reduced...... cost and power losses due to the LCCs, and ability to connect to weak AC grids due to the VSCs. The mathematical model of the power system including the HVDC link is presented. The increase in inter-area power transfer is demonstrated and compared to the case when the hybrid HVDC link is not used....... Furthermore, the transient stability of the AC/DC power system was enhanced using auxiliary controllers for Power Oscillation Damping (POD). The results show the ability of the hybrid HVDC link to increase the unidirectional inter-area power transfer, while enhancing the transient stability of the power...

  3. Variable Frequency Operations of an Offshore Wind Power Plant with HVDC-VSC: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Gevorgian, V.; Singh, M.; Muljadi, E.

    2011-12-01

    In this paper, a constant Volt/Hz operation applied to the Type 1 wind turbine generator. Various control aspects of Type 1 generators at the plant level and at the turbine level will be investigated. Based on DOE study, wind power generation may reach 330 GW by 2030 at the level of penetration of 20% of the total energy production. From this amount of wind power, 54 GW of wind power will be generated at offshore wind power plants. The deployment of offshore wind power plants requires power transmission from the plant to the load center inland. Since this power transmission requires submarine cable, there is a need to use High-Voltage Direct Current (HVDC) transmission. Otherwise, if the power is transmitted via alternating current, the reactive power generated by the cable capacitance may cause an excessive over voltage in the middle of the transmission distance which requires unnecessary oversized cable voltage breakdown capability. The use of HVDC is usually required for transmission distance longer than 50 kilometers of submarine cables to be economical. The use of HVDC brings another advantage; it is capable of operating at variable frequency. The inland substation will be operated to 60 Hz synched with the grid, the offshore substation can be operated at variable frequency, thus allowing the wind power plant to be operated at constant Volt/Hz. In this paper, a constant Volt/Hz operation applied to the Type 1 wind turbine generator. Various control aspects of Type 1 generators at the plant level and at the turbine level will be investigated.

  4. Optimization-based reactive power control in HVDC-connected wind power plants

    OpenAIRE

    Schönleber, Kevin; Collados Rodríguez, Carlos; Teixeira Pinto, Rodrigo; Ratés Palau, Sergi; Gomis Bellmunt, Oriol

    2017-01-01

    One application of high–voltage dc (HVdc) systems is the connection of remotely located offshore wind power plants (WPPs). In these systems, the offshore WPP grid and the synchronous main grid operate in decoupled mode, and the onshore HVdc converter fulfills the grid code requirements of the main grid. Thus, the offshore grid can be operated independently during normal conditions by the offshore HVdc converter and the connected wind turbines. In general, it is well known that optimized react...

  5. Economy of electric power transmission

    International Nuclear Information System (INIS)

    Manzoni, G.; Delfanti, M.

    2008-01-01

    An analysis is presented of the impact of H V and Ehv transmission costs on the final value of the kWh supplied, with reference both to transmission systems of the European type and to long distance point-to-point transmission links. The analysis is extended to A C transmission by underground cables and to Hvdc submarine and aerial links. In the European power system, the impact of transmission costs results to be usually modest, but it may become important in the case of network congestions [it

  6. DC Fault Analysis and Clearance Solutions of MMC-HVDC Systems

    Directory of Open Access Journals (Sweden)

    Zheng Xu

    2018-04-01

    Full Text Available In this paper, the DC short-circuit fault and corresponding clearance solutions of modular multilevel converter-based high-voltage direct current (MMC-HVDC systems are analyzed in detail. Firstly, the analytical expressions of DC fault currents before and after blocking the MMC are derived based on the operation circuits. Before blocking the MMC, the sub-module (SM capacitor discharge current is the dominant component of the DC fault current. It will reach the blocking threshold value in several milliseconds. After blocking the MMC, the SM capacitor is no longer discharged. Therefore, the fault current from the AC system becomes the dominant component. Meanwhile, three DC fault clearance solutions and the corresponding characteristics are discussed in detail, including tripping AC circuit breaker, adopting the full-bridge MMC and employing the DC circuit breaker. A simulation model of the MMC-HVDC is realized in PSCAD/EMTDC and the results of the proposed analytical expressions are compared with those of the simulation. The results show that the analytical DC fault currents coincide well with the simulation results.

  7. Modelling and Simulation of VSC-HVDC Connection for Wind Power Plants

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay Kumar; Teodorescu, Remus; Rodriguez, Pedro

    2009-01-01

    This paper describes the modelling and simulation of offshore wind power plants (WPP) connected to the onshore power system grid by VSC based HVDC transmission. Offshore wind power plant is modelled with several wind turbine generators connected to two separate collector buses with their own plant...... wind turbines. Simulation of power ramping up and down as well as steady state operation has been demonstrated. As an additional case, the primary reserve control logic has been implemented and simulated in PSCAD model....

  8. PowerFactory model for multi-terminal HVDC network with DC voltage droop control

    DEFF Research Database (Denmark)

    Korompili, Asimenia; Wu, Qiuwei

    Nowadays, most of the installed HVDC systems are based on line commutated converters (LCC), since this technology offers a series of advantages, mainly low costs and losses. However, voltage source converters (VSCs) have recently drawn more and more attention, due to their high controllability....... Moreover, recent developments have improved efficiency and power quality. For multi-terminal HVDC grids, the advantages of VSCs become so large, that VSC-HVDC systems are the only viable solution. Nevertheless, no VSC-based multi-terminal HVDC grids exist to date. This is the reason for which many research...

  9. A Study on the Application for Enhancing the Transmission Capability of the KEPCO Power System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Han; Kwon, Tea Won; Whang, Jong Young; Lee, Gun Joon; Kim, Tae Hoon; Chang, Byung Hoon; Min, Wan Ki [Korea Electric Power Research Institute, Taejon (Korea, Republic of); Park, Young Moon; Park, Jong Gun [Seoul National University, Seoul (Korea, Republic of); Kim, Gun Joong [Chungnam National University, Taejon (Korea, Republic of); Oh, Tae Kwu; Choi, Kwu Hyung [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-12-31

    Investigation of stability for power system in 2000 year and 2006 year by using the analysis of real power system. Comparative investigation of the conventional transmission line upgrading methods such as HVDC, HOP, new conductor scheme. Investigation of FACTS, the recent transmission line upgrading method, with respect to the aspect of technique and cost and effect analysis when this method is applied to real power system. Development of the evaluation method of transmission type that should be considered when above method is applied to real power system with respect to aspect of technique and cost. Development of a long-range plan for the transmission capacity upgrading and the evaluation method of reliability. (author).

  10. 76 FR 79206 - Commercial Renewable Energy Transmission on the Outer Continental Shelf (OCS) Offshore Mid...

    Science.gov (United States)

    2011-12-21

    ...-circuit, high-voltage direct current (HVDC) transmission line that would collect power generated by wind...-voltage alternating current into HVDC using voltage sourced converters. Each offshore converter platform... transmission grid at up to seven locations where AWC terrestrial converter stations would convert the HVDC...

  11. Transmission policy in Alberta and Bill 50

    International Nuclear Information System (INIS)

    Church, J.; Rosehart, W.; MacCormack, J.

    2009-01-01

    Plans developed by the Alberta Electric System Operator (AESO) have determined that Alberta's electrical transmission system needs to be expanded. However, there are complex issues that must be considered in order to assess the nature and extent of the needed expansion. Various new amendments to the system were proposed in the Alberta government's Bill 50, including the construction of new transmission lines; the installation of a double circuit 500 kV alternating current line between Edmonton and the Gibbons-Redwater region; the construction of a new 240 kV substation in southeast Calgary; and the installation of 2 single circuit 500 kV alternating current lines between Edmonton and Fort McMurray. This study provided a review of the institutional framework instituted by the government's transmission policy and compared the costs and benefits of 2 large capacity high voltage DC (HVDC) transmission lines proposed for the Edmonton-Calgary corridor relative to the various other transmission system amendment suggestions. An evaluation of Alberta's proposed regulatory process under Bill 50 was also conducted. Results of the study indicated that the addition of the HVDC lines is an inefficient response to concerns over adequate supply and reliability. 72 refs., 18 tabs.

  12. Relevance of HVDC for electrical power supply; Bedeutung der HGUein der Energieversorgung

    Energy Technology Data Exchange (ETDEWEB)

    Gambach, Herbert; Dorn, Joerg [Siemens AG, Erlangen (Germany). Power Transmission Solutions

    2012-07-01

    The finite availability of fossil energy, the turning away of many countries from nuclear power generation and the need for a limitation of CO{sub 2} emissions influence the future generation and transmission of electrical power in a significant way. In the long term these requirements can be met only by renewable energy sources, for instance solar power and wind. Another aspect is that power generation facilities are in many cases far-off from the load centers. This enforces reliable transmission systems with low losses over long distances. The high voltage direct current (HVDC) transmission complies with these demands in a beneficial way. This paper gives a short overview of the state-of-the-art and describes current developments. (orig.)

  13. A Proposal on Low Frequency AC Transmission as a Multi-Terminal Transmission System

    Directory of Open Access Journals (Sweden)

    Achara Pichetjamroen

    2016-08-01

    Full Text Available This paper is focused on the discussion and comparison of characteristics and behavior of three low frequency ac (LFAC transmission system configurations operating under the same control scheme and conditions to identify the most promising operation system for LFAC. Merits of LFAC over high voltage direct current (HVDC are mentioned first. By changing power flow direction without auxiliary switches in multi-terminal application and easiness of short circuit protection are explained. The three configurations of LFACs are described and applied by the control scheme with the aid of the tool of the PSCAD/EMTDC software to consider the behavior of each LFAC system on line frequency and low frequency sides. For two-phase system, no fluctuation occurs on the line frequency side, which is the advantage over single-phase system. Furthermore, current rating on thyristor devices during operation and number of devices that used in each type of LFAC are calculated and compared. These results can lead to determine the most suitable transmission system for the LFAC system operation.

  14. Influence of current limitation on voltage stability with voltage sourced converter HVDC

    DEFF Research Database (Denmark)

    Zeni, Lorenzo; Jóhannsson, Hjörtur; Hansen, Anca Daniela

    2013-01-01

    A first study of voltage stability with relevant amount of Voltage Sourced Converter based High Voltage Direct Current (VSC-HVDC) transmission is presented, with particular focus on the converters’ behaviour when reaching their rated current. The detrimental effect of entering the current...

  15. Operation and control of a DC-grid offshore wind farm under DC transmission system faults

    DEFF Research Database (Denmark)

    Deng, Fujin; Chen, Zhe

    2013-01-01

    . Consequently, the protection and control strategies of dc systems need to be established. This paper studies a dc-grid offshore wind farm, where the wind power collection system and power transmission system adopt dc technology. In this paper, the redundancy of the HVDC transmission system under faults...... is studied, and a fault ridethrough strategy for the dc-grid offshore wind farm is proposed. The proposed strategy can effectively minimize the impacts of the power transmission system disturbance on the offshore wind farm, and on the ac grid. A dc-grid offshore wind farm example is simulated with PSCAD....../EMTDC, and the results validate the feasibility of the presented redundancy configuration and operation approach, and the fault ridethrough control strategy....

  16. DFIG-based offshore wind power plant connected to a single VSC-HVDC operated at variable frequency: Energy yield assessment

    International Nuclear Information System (INIS)

    De-Prada-Gil, Mikel; Díaz-González, Francisco; Gomis-Bellmunt, Oriol; Sumper, Andreas

    2015-01-01

    The existence of HVDC (High Voltage Direct Current) transmission systems for remote offshore wind power plants allows devising novel wind plant concepts, which do not need to be synchronized with the main AC grid. This paper proposes an OWPP (offshore wind power plant) design based on variable speed wind turbines driven by DFIGs (doubly fed induction generators) with reduced power electronic converters connected to a single VSC-HVDC converter which operates at variable frequency and voltage within the collection grid. It is aimed to evaluate the influence of the power converter size and wind speed variability within the WPP on energy yield efficiency, as well as to develop a coordinated control between the VSC-HVDC converter and the individual back-to-back reduced power converters of each DFIG-based wind turbine in order to provide control capability for the wind power plant at a reduced cost. To maximise wind power generation by the OWPP, an optimum electrical frequency search algorithm for the VSC-HVDC converter is proposed. Both central wind power plant control level and local wind turbine control level are presented and the performance of the system is validated by means of simulations using MATLAB/Simulink ® . - Highlights: • Influence of converter size and wind speed variability on energy capture efficiency. • Coordinated control between a VSC-HVDC and DFIG WTs with reduced power converters. • Static and dynamic analysis of the performance of the implemented control scheme. • Optimal variable frequency operation to maximize WPP generation at a reduced cost

  17. Simplified Analytic Approach of Pole-to-Pole Faults in MMC-HVDC for AC System Backup Protection Setting Calculation

    Directory of Open Access Journals (Sweden)

    Tongkun Lan

    2018-01-01

    Full Text Available AC (alternating current system backup protection setting calculation is an important basis for ensuring the safe operation of power grids. With the increasing integration of modular multilevel converter based high voltage direct current (MMC-HVDC into power grids, it has been a big challenge for the AC system backup protection setting calculation, as the MMC-HVDC lacks the fault self-clearance capability under pole-to-pole faults. This paper focused on the pole-to-pole faults analysis for the AC system backup protection setting calculation. The principles of pole-to-pole faults analysis were discussed first according to the standard of the AC system protection setting calculation. Then, the influence of fault resistance on the fault process was investigated. A simplified analytic approach of pole-to-pole faults in MMC-HVDC for the AC system backup protection setting calculation was proposed. In the proposed approach, the derived expressions of fundamental frequency current are applicable under arbitrary fault resistance. The accuracy of the proposed approach was demonstrated by PSCAD/EMTDC (Power Systems Computer-Aided Design/Electromagnetic Transients including DC simulations.

  18. Adaptive Modulation for DFIG and STATCOM With High-Voltage Direct Current Transmission.

    Science.gov (United States)

    Tang, Yufei; He, Haibo; Ni, Zhen; Wen, Jinyu; Huang, Tingwen

    2016-08-01

    This paper develops an adaptive modulation approach for power system control based on the approximate/adaptive dynamic programming method, namely, the goal representation heuristic dynamic programming (GrHDP). In particular, we focus on the fault recovery problem of a doubly fed induction generator (DFIG)-based wind farm and a static synchronous compensator (STATCOM) with high-voltage direct current (HVDC) transmission. In this design, the online GrHDP-based controller provides three adaptive supplementary control signals to the DFIG controller, STATCOM controller, and HVDC rectifier controller, respectively. The mechanism is to observe the system states and their derivatives and then provides supplementary control to the plant according to the utility function. With the GrHDP design, the controller can adaptively develop an internal goal representation signal according to the observed power system states, therefore, to achieve more effective learning and modulating. Our control approach is validated on a wind power integrated benchmark system with two areas connected by HVDC transmission lines. Compared with the classical direct HDP and proportional integral control, our GrHDP approach demonstrates the improved transient stability under system faults. Moreover, experiments under different system operating conditions with signal transmission delays are also carried out to further verify the effectiveness and robustness of the proposed approach.

  19. Hybrid Models of Alternative Current Filter for Hvdc

    Directory of Open Access Journals (Sweden)

    Ufa Ruslan A.

    2017-01-01

    Full Text Available Based on a hybrid simulation concept of HVDC, the developed hybrid AC filter models, providing the sufficiently full and adequate modeling of all single continuous spectrum of quasi-steady-state and transient processes in the filter, are presented. The obtained results suggest that usage of the hybrid simulation approach is carried out a methodically accurate with guaranteed instrumental error solution of differential equation systems of mathematical models of HVDC.

  20. Modeling and real time simulation of an HVDC inverter feeding a weak AC system based on commutation failure study.

    Science.gov (United States)

    Mankour, Mohamed; Khiat, Mounir; Ghomri, Leila; Chaker, Abdelkader; Bessalah, Mourad

    2018-06-01

    This paper presents modeling and study of 12-pulse HVDC (High Voltage Direct Current) based on real time simulation where the HVDC inverter is connected to a weak AC system. In goal to study the dynamic performance of the HVDC link, two serious kind of disturbance are applied at HVDC converters where the first one is the single phase to ground AC fault and the second one is the DC link to ground fault. The study is based on two different mode of analysis, which the first is to test the performance of the DC control and the second is focalized to study the effect of the protection function on the system behavior. This real time simulation considers the strength of the AC system to witch is connected and his relativity with the capacity of the DC link. The results obtained are validated by means of RT-lab platform using digital Real time simulator Hypersim (OP-5600), the results carried out show the effect of the DC control and the influence of the protection function to reduce the probability of commutation failures and also for helping inverter to take out from commutation failure even while the DC control fails to eliminate them. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  1. Synthesis of a hybrid model of the VSC FACTS devices and HVDC technologies

    Science.gov (United States)

    Borovikov, Yu S.; Gusev, A. S.; Sulaymanov, A. O.; Ufa, R. A.

    2014-10-01

    The motivation of the presented research is based on the need for development of new methods and tools for adequate simulation of FACTS devices and HVDC systems as part of real electric power systems (EPS). The Research object: An alternative hybrid approach for synthesizing VSC-FACTS and -HVDC hybrid model is proposed. The results: the VSC- FACTS and -HVDC hybrid model is designed in accordance with the presented concepts of hybrid simulation. The developed model allows us to carry out adequate simulation in real time of all the processes in HVDC, FACTS devices and EPS as a whole without any decomposition and limitation on their duration, and also use the developed tool for effective solution of a design, operational and research tasks of EPS containing such devices.

  2. Synthesis of a hybrid model of the VSC FACTS devices and HVDC technologies

    International Nuclear Information System (INIS)

    Borovikov, Yu S; Gusev, A S; Sulaymanov, A O; Ufa, R A

    2014-01-01

    The motivation of the presented research is based on the need for development of new methods and tools for adequate simulation of FACTS devices and HVDC systems as part of real electric power systems (EPS). The Research object: An alternative hybrid approach for synthesizing VSC-FACTS and -HVDC hybrid model is proposed. The results: the VSC- FACTS and -HVDC hybrid model is designed in accordance with the presented concepts of hybrid simulation. The developed model allows us to carry out adequate simulation in real time of all the processes in HVDC, FACTS devices and EPS as a whole without any decomposition and limitation on their duration, and also use the developed tool for effective solution of a design, operational and research tasks of EPS containing such devices

  3. 78 FR 50405 - Amended Application for Presidential Permit; Northern Pass Transmission LLC

    Science.gov (United States)

    2013-08-19

    ... Pass proposes to construct and operate a primarily overhead high-voltage direct current (HVDC) electric transmission line that would originate at an HVDC converter station to be constructed at the Des Cantons Substation in Qu[eacute]bec, Canada, then would be converted from HVDC to alternating current (AC) in...

  4. Evaluating the merchant transmission market

    International Nuclear Information System (INIS)

    Hsieh, E.; Bartholomew Fisher, E.

    2007-01-01

    This paper reviewed the North American bulk electric transmission system, with particular reference to the following merchant power transmission projects that have applied to sell transmission at negotiated rates by the Federal Energy Regulatory Commission (FERC): Cross Sound Cable; Neptune Phase 1; TransCanada's Northern Lights HVDC line; Montana Alberta Tie; Juan de Fuca Cable; Linden VFT; Connecticut-Long Island Cable; Lake Erie Link; Empire Connection; Harbor Cable; Chesapeake Transmission; and the Neptune/Green Line. The projects were sorted by status as either active, inactive and restructured. Each summary included the interconnection points, capacity, and sponsor. This paper also identified the major hurdles in their approvals. The relative success of the merchant transmission framework in attracting new investment was then reviewed. The successful projects shared 3 common attributes. They connected areas with large price differentials and they used advanced flow control technology such as HVDC, PARs, and VFTs. The successful projects also bridged some type of border, either geographic, electrical, economic, or a combination. Three of the active projects crossed the Canadian-US border, while the other 3 connected New York City to neighbouring regions. It was shown that merchant transmission fills a niche, enabling market responses to connect areas that may be overlooked by a regional planning process. 27 refs

  5. The need for a common standard for voltage levels of HVDC VSC technology

    International Nuclear Information System (INIS)

    Müller, H.K.; Torbaghan, S. Shariat; Gibescu, M.; Roggenkamp, M.M.; Meijden, M.A.M.M. van der

    2013-01-01

    The expansion of offshore wind energy as well as the increase in electricity trade between the North Sea countries leads to a growing need for additional transmission capacity. Due to the predominantly remote locations of offshore wind farms, the majority of future connections will be high-voltage direct current (HVDC) connections. In order to make the construction of offshore infrastructure more efficient, the North Sea states are currently discussing the development of a common offshore grid. Although this development still stands at the very beginning, we argue in this paper that some crucial elements should be standardized from the outset; the most important one being a common voltage level. Without such standardization, the development of a European offshore grid may be suboptimal, not cost-efficient and might even be prevented from coming into existence. We examine the technical and legal issues associated with introducing a common voltage level for the use of HVDC VSC technology, and discuss the optimal standard as well as the way in which this common standard can best be achieved. - Highlights: • We highlight the need for a common standard for HVDC VSC technology. • We outline that a standardized voltage level at ± 500 kV should be the initial focus. • We discuss the developments regarding standardization of HVDC VSC technology. • We conclude that current developments are not sufficient

  6. Improvement of Wind Energy Production through HVDC Systems

    Directory of Open Access Journals (Sweden)

    Morris Brenna

    2017-01-01

    Full Text Available Variable and non-programmable resources, such as solar and wind, have undergone a stunning growth in recent years and are likely to gain even more importance in the future. Their strong presence in the national electricity mix has created issues in many countries regarding the secure operation of the power system. In order to guarantee the stability of the system, several TSOs have resorted to wind energy curtailment, which represents a waste of clean energy and an economic loss. In order to analyze this issue, a model of the Italian power system was developed, a program able to simulate the electricity dispatching mechanism. The model was, then, used to evaluate possible solutions to reduce wind curtailment. In particular, a proposal for the construction of an HVDC line linking Southern and Northern Italy was studied.

  7. Grid-connection of offshore wind farms using VSC-HVDC systems

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Xiaofan; Dessaint, Louis A. [Ecole de Technologie Superieure, Montreal, QC (Canada). Dept. of Electrical Engineering; Gagnon, Richard [Hydro-Quebec Research Institute, Montreal, QC (Canada)

    2011-07-01

    In this paper, the structure of variable speed PMSG-based offshore wind farms connected to the grid through VSC-HVDC link is presented. And the system models are developed. Also, the corresponding control strategy for this system is proposed. The control objective of the generator side VSC is to achieve the optimal wind power by adjusting the speed of permanent magnet synchronous generator, while the grid side VSC is to maintain DC voltage constant. Furthermore, a case study of 100MW offshore wind farm consisting of 50 individual 2MW PSMG-based wind turbines is developed in MATLAB/SimPowerSystems. Simulation results show the proposed scheme works well. (orig.)

  8. WSN-Based Space Charge Density Measurement System.

    Science.gov (United States)

    Deng, Dawei; Yuan, Haiwen; Lv, Jianxun; Ju, Yong

    2017-01-01

    It is generally acknowledged that high voltage direct current (HVDC) transmission line endures the drawback of large area, because of which the utilization of cable for space charge density monitoring system is of inconvenience. Compared with the traditional communication network, wireless sensor network (WSN) shows advantages in small volume, high flexibility and strong self-organization, thereby presenting great potential in solving the problem. Additionally, WSN is more suitable for the construction of distributed space charge density monitoring system as it has longer distance and higher mobility. A distributed wireless system is designed for collecting and monitoring the space charge density under HVDC transmission lines, which has been widely applied in both Chinese state grid HVDC test base and power transmission projects. Experimental results of the measuring system demonstrated its adaptability in the complex electromagnetic environment under the transmission lines and the ability in realizing accurate, flexible, and stable demands for the measurement of space charge density.

  9. Dynamic modelling of VSC-HVDC for connection of offshore wind farms

    DEFF Research Database (Denmark)

    Rios, Bardo; Garcia-Valle, Rodrigo

    2011-01-01

    A VSC-HVDC (Voltage Source Converter – High Voltage Direct Current) dynamic model with a set of control strategies is developed in DIgSILENT Power-Factory with the objective of analyzing the converter’s operating capability for grid support during grid faults. The investigation is carried out based...... on a 165 MW offshore wind farm with induction generators and a Low Voltage Ride-Through solution of the offshore wind turbines and Static Voltage Compensator units in the point of connection with a grid represented by a reduced four-generator power grid model. VSC-HVDC promises to be a reliable alternative...... solution for interconnection with off-shore wind farms as they become larger, with a higher installed power capacity, increased number of wind turbines, and geographically situated at larger distances from suitable connection points in the transmission grids....

  10. Kingsnorth-London dc transmission link

    Energy Technology Data Exchange (ETDEWEB)

    1966-03-11

    The hvdc transmission link between one of the 500 MW generators at Kingsnorth Power Station and two receiving stations in London will use a three-wire dc cable system rated to carry 1200 A at +- 266 kV. This 51-mile system will be the first dc link in the world to be used as an integral part of a complex interconnected ac network.

  11. Feasibility analysis of a novel hybrid-type superconducting circuit breaker in multi-terminal HVDC networks

    Science.gov (United States)

    Khan, Umer Amir; Lee, Jong-Geon; Seo, In-Jin; Amir, Faisal; Lee, Bang-Wook

    2015-11-01

    Voltage source converter-based HVDC systems (VSC-HVDC) are a better alternative than conventional thyristor-based HVDC systems, especially for developing multi-terminal HVDC systems (MTDC). However, one of the key obstacles in developing MTDC is the absence of an adequate protection system that can quickly detect faults, locate the faulty line and trip the HVDC circuit breakers (DCCBs) to interrupt the DC fault current. In this paper, a novel hybrid-type superconducting circuit breaker (SDCCB) is proposed and feasibility analyses of its application in MTDC are presented. The SDCCB has a superconducting fault current limiter (SFCL) located in the main current path to limit fault currents until the final trip signal is received. After the trip signal the IGBT located in the main line commutates the current into a parallel line where DC current is forced to zero by the combination of IGBTs and surge arresters. Fault simulations for three-, four- and five-terminal MTDC were performed and SDCCB performance was evaluated in these MTDC. Passive current limitation by SFCL caused a significant reduction of fault current interruption stress in the SDCCB. It was observed that the DC current could change direction in MTDC after a fault and the SDCCB was modified to break the DC current in both the forward and reverse directions. The simulation results suggest that the proposed SDCCB could successfully suppress the DC fault current, cause a timely interruption, and isolate the faulty HVDC line in MTDC.

  12. Modeling of HVDC System to Improve Estimation of Transient DC Current and Voltages for AC Line-to-Ground Fault—An Actual Case Study in Korea

    Directory of Open Access Journals (Sweden)

    Dohoon Kwon

    2017-10-01

    Full Text Available A new modeling method for high voltage direct current (HVDC systems and associated controllers is presented for the power system simulator for engineering (PSS/E simulation environment. The aim is to improve the estimation of the transient DC voltage and current in the event of an AC line-to-ground fault. The proposed method consists primary of three interconnected modules for (a equation conversion; (b control-mode selection; and (c DC-line modeling. Simulation case studies were carried out using PSS/E and a power systems computer aided design/electromagnetic transients including DC (PSCAD/EMTDC model of the Jeju– Haenam HVDC system in Korea. The simulation results are compared with actual operational data and the PSCAD/EMTDC simulation results for an HVDC system during single-phase and three-phase line-to-ground faults, respectively. These comparisons show that the proposed PSS/E modeling method results in the improved estimation of the dynamic variation in the DC voltage and current in the event of an AC network fault, with significant gains in computational efficiency, making it suitable for real-time analysis of HVDC systems.

  13. Nonlinear Control of Back-to-Back VSC-HVDC System via Command-Filter Backstepping

    Directory of Open Access Journals (Sweden)

    Jie Huang

    2017-01-01

    Full Text Available This paper proposed a command-filtered backstepping controller to improve the dynamic performance of back-to-back voltage-source-converter high voltage direct current (BTB VSC-HVDC. First, the principle and model of BTB VSC-HVDC in abc and d-q frame are described. Then, backstepping method is applied to design a controller to maintain the voltage balance and realize coordinated control of active and reactive power. Meanwhile, command filter is introduced to deal with the problem of input saturation and explosion of complexity in conventional backstepping, and a filter compensation signal is designed to diminish the adverse effects caused by the command filter. Next, the stability and convergence of the whole system are proved via the Lyapunov theorem of asymptotic stability. Finally, simulation results are given to demonstrate that proposed controller has a better dynamic performance and stronger robustness compared to the traditional PID algorithm, which also proves the effectiveness and possibility of the designed controller.

  14. The effect of FRT behavior of VSC-HVDC-connected offshore wind power plants on AC/DC system dynamics

    NARCIS (Netherlands)

    van der Meer, A.A.; Ndreko, M.; Gibescu, M.; van der Meijden, M.A.M.M.

    2016-01-01

    Future power systems will contain more converter-based generation, among which are the voltage-source converter-high-voltage direct-current (VSC-HVDC)-connected offshore wind power plants (WPP). Their interaction with the onshore system influences power system dynamics in the transient stability

  15. A Combined Reliability Model of VSC-HVDC Connected Offshore Wind Farms Considering Wind Speed Correlation

    DEFF Research Database (Denmark)

    Guo, Yifei; Gao, Houlei; Wu, Qiuwei

    2017-01-01

    and WTGs outage. The wind speed correlation between different WFs is included in the two-dimensional multistate WF model by using an improved k-means clustering method. Then, the entire system with two WFs and a threeterminal VSC-HVDC system is modeled as a multi-state generation unit. The proposed model...... is applied to the Roy Billinton test system (RBTS) for adequacy studies. Both the probability and frequency indices are calculated. The effectiveness and accuracy of the combined model is validated by comparing results with the sequential Monte Carlo simulation (MCS) method. The effects of the outage of VSC-HVDC...... system and wind speed correlation on the system reliability were analyzed. Sensitivity analyses were conducted to investigate the impact of repair time of the offshore VSC-HVDC system on system reliability....

  16. Geothermal electric power generation in Iceland for the proposed Iceland/United Kingdom HVDC power link

    International Nuclear Information System (INIS)

    Hammons, T.J.; Palmason, G.; Thorhallsson, S.

    1991-01-01

    The paper reviews geothermal electric power potential in Iceland which could economically be developed to supplement hydro power for the proposed HVDC Power Link to the United Kingdom, and power intensive industries in Iceland, which are envisaged for development at this time. Technically harnessable energy for electricity generation taking account of geothermal resources down to an assumed base depth, temperature distribution in the crust, probable geothermal recovery factor, and accessibility of the field, has been assessed. Nineteen known high-temperature fields and 9 probable fields have been identified. Technically harnessable geo-heat for various areas is indicated. Data on high temperature fields suitable for geothermal electric power generation, and on harnessable energy for electric power generation within volcanic zones, is stated, and overall assessments are made. The paper then reviews how the potential might be developed, discussing preference of possible sites, and cost of the developments at todays prices. Cost of geothermal electric power generation with comparative costs for hydro generation are given. Possible transmission system developments to feed the power to the proposed HVDC Link converter stations are also discussed

  17. HVDC transmission preferred to 750 kV ac

    Energy Technology Data Exchange (ETDEWEB)

    1965-06-25

    It is unlikely that there will be a need in Britain for ac transmission voltages above 400 kV. But with the growing load density in the large conurbations with no possibility of local generation, high voltage dc transmission is likely to be most useful. It was concluded that by 1971 the 400 kV supergrid would be nation-wide and 6,200 circuit miles should be in service. With the expansion to accommodate the large new generating stations, the 400 kV supergrid would become an extremely high power distribution network rather than a transmission system. A higher voltage for transmission is outside the rational limit of speculation for a country the size of Britain.

  18. Voltage-current characteristics of multiterminal HVDC-VSC for offshore wind farms

    Energy Technology Data Exchange (ETDEWEB)

    Gomis-Bellmunt, Oriol [Centre d' Innovacio Tecnologica en Convertidors Estatics i Accionaments (CITCEA-UPC), Universitat Politecnica de Catalunya UPC, Av. Diagonal, 647, Pl. 2., 08028 Barcelona (Spain); IREC Catalonia Institute for Energy Research, Barcelona (Spain); Liang, Jun; Ekanayake, Janaka; Jenkins, Nicholas [School of Engineering, Cardiff University, Queen' s Buildings, The Parade, Cardiff CF24 3AA, Wales (United Kingdom)

    2011-02-15

    Voltage-current characteristics and equilibrium points for the DC voltages of multiterminal HVDC systems using voltage source converters are discussed. The wind farm rectifiers and grid connected inverters are analyzed through their operating modes, governing equations and graphical characteristics. Using the converter equations and the HVDC grid conductance matrix the equilibrium voltages and currents are found. Case studies are presented considering wind power generation, loss of a converter and voltage sags in the AC grid. (author)

  19. Feasibility analysis of a novel hybrid-type superconducting circuit breaker in multi-terminal HVDC networks

    International Nuclear Information System (INIS)

    Khan, Umer Amir; Lee, Jong-Geon; Seo, In-Jin; Amir, Faisal; Lee, Bang-Wook

    2015-01-01

    Highlights: • A novel hybrid-type superconducting circuit breaker (SDCCB) is proposed. • SDCCB has SFCL located in the main current path to limit the fault current until the final trip signal. • SFCL in SDCCB suppressed the fast rising DC fault current for a predefined time. • SFCL significantly reduced the DC current breaking stress on SDCCB components. • SDCCB isolated the HVDC faulty line in three, four, and five converter stations MTDC. - Abstract: Voltage source converter-based HVDC systems (VSC-HVDC) are a better alternative than conventional thyristor-based HVDC systems, especially for developing multi-terminal HVDC systems (MTDC). However, one of the key obstacles in developing MTDC is the absence of an adequate protection system that can quickly detect faults, locate the faulty line and trip the HVDC circuit breakers (DCCBs) to interrupt the DC fault current. In this paper, a novel hybrid-type superconducting circuit breaker (SDCCB) is proposed and feasibility analyses of its application in MTDC are presented. The SDCCB has a superconducting fault current limiter (SFCL) located in the main current path to limit fault currents until the final trip signal is received. After the trip signal the IGBT located in the main line commutates the current into a parallel line where DC current is forced to zero by the combination of IGBTs and surge arresters. Fault simulations for three-, four- and five-terminal MTDC were performed and SDCCB performance was evaluated in these MTDC. Passive current limitation by SFCL caused a significant reduction of fault current interruption stress in the SDCCB. It was observed that the DC current could change direction in MTDC after a fault and the SDCCB was modified to break the DC current in both the forward and reverse directions. The simulation results suggest that the proposed SDCCB could successfully suppress the DC fault current, cause a timely interruption, and isolate the faulty HVDC line in MTDC.

  20. Feasibility analysis of a novel hybrid-type superconducting circuit breaker in multi-terminal HVDC networks

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Umer Amir [Hanyang University, Sa-3dong, Sangrok-gu, Ansan 426-791 (Korea, Republic of); National University of Sciences and Technology, PNEC Campus, Habib Rehmatullah Road, Karachi (Pakistan); Lee, Jong-Geon; Seo, In-Jin [Hanyang University, Sa-3dong, Sangrok-gu, Ansan 426-791 (Korea, Republic of); Amir, Faisal [National University of Sciences and Technology, PNEC Campus, Habib Rehmatullah Road, Karachi (Pakistan); Lee, Bang-Wook, E-mail: bangwook@hanyang.ac.kr [Hanyang University, Sa-3dong, Sangrok-gu, Ansan 426-791 (Korea, Republic of)

    2015-11-15

    Highlights: • A novel hybrid-type superconducting circuit breaker (SDCCB) is proposed. • SDCCB has SFCL located in the main current path to limit the fault current until the final trip signal. • SFCL in SDCCB suppressed the fast rising DC fault current for a predefined time. • SFCL significantly reduced the DC current breaking stress on SDCCB components. • SDCCB isolated the HVDC faulty line in three, four, and five converter stations MTDC. - Abstract: Voltage source converter-based HVDC systems (VSC-HVDC) are a better alternative than conventional thyristor-based HVDC systems, especially for developing multi-terminal HVDC systems (MTDC). However, one of the key obstacles in developing MTDC is the absence of an adequate protection system that can quickly detect faults, locate the faulty line and trip the HVDC circuit breakers (DCCBs) to interrupt the DC fault current. In this paper, a novel hybrid-type superconducting circuit breaker (SDCCB) is proposed and feasibility analyses of its application in MTDC are presented. The SDCCB has a superconducting fault current limiter (SFCL) located in the main current path to limit fault currents until the final trip signal is received. After the trip signal the IGBT located in the main line commutates the current into a parallel line where DC current is forced to zero by the combination of IGBTs and surge arresters. Fault simulations for three-, four- and five-terminal MTDC were performed and SDCCB performance was evaluated in these MTDC. Passive current limitation by SFCL caused a significant reduction of fault current interruption stress in the SDCCB. It was observed that the DC current could change direction in MTDC after a fault and the SDCCB was modified to break the DC current in both the forward and reverse directions. The simulation results suggest that the proposed SDCCB could successfully suppress the DC fault current, cause a timely interruption, and isolate the faulty HVDC line in MTDC.

  1. Development of toroid-type HTS DC reactor series for HVDC system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kwangmin, E-mail: kwangmin81@gmail.com [Changwon National University, 55306 Sarim-dong, Changwon 641-773 (Korea, Republic of); Go, Byeong-Soo; Park, Hea-chul; Kim, Sung-kyu; Kim, Seokho [Changwon National University, 55306 Sarim-dong, Changwon 641-773 (Korea, Republic of); Lee, Sangjin [Uiduk University, Gyeongju 780-713 (Korea, Republic of); Oh, Yunsang [Vector Fields Korea Inc., Pohang 790-834 (Korea, Republic of); Park, Minwon; Yu, In-Keun [Changwon National University, 55306 Sarim-dong, Changwon 641-773 (Korea, Republic of)

    2015-11-15

    Highlights: • The authors developed the 400 mH, 400 A class toroid-type HTS DC reactor system. • The target temperature, inductance and operating current are under 20 K at magnet, 400 mH and 400 A, respectively. All target performances of the HTS DC reactor were achieved. • The HTS DC reactor was conducted through the interconnection operation with a LCC type HVDC system. • Now, the authors are studying the 400 mH, 1500 A class toroid-type HTS DC reactor for the next phase HTS DC reactor. - Abstract: This paper describes design specifications and performance of a toroid-type high-temperature superconducting (HTS) DC reactor. The first phase operation targets of the HTS DC reactor were 400 mH and 400 A. The authors have developed a real HTS DC reactor system during the last three years. The HTS DC reactor was designed using 2G GdBCO HTS wires. The HTS coils of the toroid-type DC reactor magnet were made in the form of a D-shape. The electromagnetic performance of the toroid-type HTS DC reactor magnet was analyzed using the finite element method program. A conduction cooling method was adopted for reactor magnet cooling. The total system has been successfully developed and tested in connection with LCC type HVDC system. Now, the authors are studying a 400 mH, kA class toroid-type HTS DC reactor for the next phase research. The 1500 A class DC reactor system was designed using layered 13 mm GdBCO 2G HTS wire. The expected operating temperature is under 30 K. These fundamental data obtained through both works will usefully be applied to design a real toroid-type HTS DC reactor for grid application.

  2. Development of toroid-type HTS DC reactor series for HVDC system

    International Nuclear Information System (INIS)

    Kim, Kwangmin; Go, Byeong-Soo; Park, Hea-chul; Kim, Sung-kyu; Kim, Seokho; Lee, Sangjin; Oh, Yunsang; Park, Minwon; Yu, In-Keun

    2015-01-01

    Highlights: • The authors developed the 400 mH, 400 A class toroid-type HTS DC reactor system. • The target temperature, inductance and operating current are under 20 K at magnet, 400 mH and 400 A, respectively. All target performances of the HTS DC reactor were achieved. • The HTS DC reactor was conducted through the interconnection operation with a LCC type HVDC system. • Now, the authors are studying the 400 mH, 1500 A class toroid-type HTS DC reactor for the next phase HTS DC reactor. - Abstract: This paper describes design specifications and performance of a toroid-type high-temperature superconducting (HTS) DC reactor. The first phase operation targets of the HTS DC reactor were 400 mH and 400 A. The authors have developed a real HTS DC reactor system during the last three years. The HTS DC reactor was designed using 2G GdBCO HTS wires. The HTS coils of the toroid-type DC reactor magnet were made in the form of a D-shape. The electromagnetic performance of the toroid-type HTS DC reactor magnet was analyzed using the finite element method program. A conduction cooling method was adopted for reactor magnet cooling. The total system has been successfully developed and tested in connection with LCC type HVDC system. Now, the authors are studying a 400 mH, kA class toroid-type HTS DC reactor for the next phase research. The 1500 A class DC reactor system was designed using layered 13 mm GdBCO 2G HTS wire. The expected operating temperature is under 30 K. These fundamental data obtained through both works will usefully be applied to design a real toroid-type HTS DC reactor for grid application.

  3. Evaluation of HVDC interconnection models for considering its impact in real-time voltage stability assessment

    DEFF Research Database (Denmark)

    Perez, Angel; Jóhannsson, Hjörtur; Lund, P.

    2015-01-01

    An approach to evaluate the HVDC interconnectionsmodels to be used in real-time voltage stability assessment is proposed.The existing models for the HVDC interconnections, thatare based on voltage source converter, were studied selecting theones that are suitable for its application in Thevenin...... equivalent ´methods for voltage stability assessment. The proposed methodis to evaluate the validity of the models by using synthetizedPMU measurements from simulations and from PMUs connectedto the danish system. Wide-area measurements are used toestimate the HVDC model parameters which are needed...

  4. Overvoltage and Insulation Coordination of Overhead Lines in Multiple-Terminal MMC-HVDC Link for Wind Power Delivery

    Directory of Open Access Journals (Sweden)

    Huiwen He

    2017-01-01

    Full Text Available The voltage-sourced converter-based HVDC link, including the modular multilevel converter (MMC configuration, is suitable for wind power, photovoltaic energy, and other kinds of new energy delivery and grid-connection. Current studies are focused on the MMC principles and controls and few studies have been done on the overvoltage of transmission line for the MMC-HVDC link. The main reason is that environmental factors have little effect on DC cables and the single-phase/pole fault rate is low. But if the cables were replaced by the overhead lines, although the construction cost of the project would be greatly reduced, the single-pole ground fault rate would be much higher. This paper analyzed the main overvoltage types in multiple-terminal MMC-HVDC network which transmit electric power by overhead lines. Based on ±500 kV multiple-terminal MMC-HVDC for wind power delivery project, the transient simulation model was built and the overvoltage types mentioned above were studied. The results showed that the most serious overvoltage was on the healthy adjacent line of the faulty line caused by the fault clearing of DC breaker. Then the insulation coordination for overhead lines was conducted according to the overvoltage level. The recommended clearance values were given.

  5. Measurement of surface charges on the dielectric film based on field mills under the HVDC corona wire

    Science.gov (United States)

    Donglai, WANG; Tiebing, LU; Yuan, WANG; Bo, CHEN; Xuebao, LI

    2018-05-01

    The ion flow field on the ground is one of the significant parameters used to evaluate the electromagnetic environment of high voltage direct current (HVDC) power lines. HVDC lines may cross the greenhouses due to the restricted transmission corridors. Under the condition of ion flow field, the dielectric films on the greenhouses will be charged, and the electric fields in the greenhouses may exceed the limit value. Field mills are widely used to measure the ground-level direct current electric fields under the HVDC power lines. In this paper, the charge inversion method is applied to calculate the surface charges on the dielectric film according to the measured ground-level electric fields. The advantages of hiding the field mill probes in the ground are studied. The charge inversion algorithm is optimized in order to decrease the impact of measurement errors. Based on the experimental results, the surface charge distribution on a piece of quadrate dielectric film under a HVDC corona wire is studied. The enhanced effect of dielectric film on ground-level electric field is obviously weakened with the increase of film height. Compared with the total electric field strengths, the normal components of film-free electric fields at the corresponding film-placed positions have a higher effect on surface charge accumulation.

  6. Marine High Voltage Power Conditioning and Transmission System with Integrated Storage DE-EE0003640 Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Frank Hoffmann, PhD; Aspinall, Rik

    2012-12-10

    Design, Development, and test of the three-port power converter for marine hydrokinetic power transmission. Converter provides ports for AC/DC conversion of hydrokinetic power, battery storage, and a low voltage to high voltage DC port for HVDC transmission to shore. The report covers the design, development, implementation, and testing of a prototype built by PPS.

  7. Reliability analysis of HVDC grid combined with power flow simulations

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yongtao; Langeland, Tore; Solvik, Johan [DNV AS, Hoevik (Norway); Stewart, Emma [DNV KEMA, Camino Ramon, CA (United States)

    2012-07-01

    Based on a DC grid power flow solver and the proposed GEIR, we carried out reliability analysis for a HVDC grid test system proposed by CIGRE working group B4-58, where the failure statistics are collected from literature survey. The proposed methodology is used to evaluate the impact of converter configuration on the overall reliability performance of the HVDC grid, where the symmetrical monopole configuration is compared with the bipole with metallic return wire configuration. The results quantify the improvement on reliability by using the later alternative. (orig.)

  8. Fault Ride-Through Capability Enhancement of VSC HVDC connected Offshore Wind Power Plants

    DEFF Research Database (Denmark)

    Sharma, Ranjan; Wu, Qiuwei; Cha, Seung-Tae

    2015-01-01

    This paper presents a feed forward direct current (DC) voltage control based fault ride-through (FRT) scheme for voltage source converter (VSC) high voltage DC (HVDC) connected offshore wind power plants (WPPs) in order to achieve active control of the WPP collector network AC voltage magnitude......, and to improve the FRT capability. During steady state operation, an open loop AC voltage control is implemented at the WPP side VSC of the HVDC system such that any possible control interactions between the WPP side VSC and the wind turbine VSC are minimized. Whereas during any grid faults, a dynamic AC voltage...... reference is applied based on both the DC voltage error and the AC active-current from the WPP collector system which ensures fast and robust FRT of the VSC HVDC connected offshore WPPs. Under unbalanced fault conditions in the host power system, the resulting oscillatory DC voltage is directly used...

  9. Control of offshore wind farms with HVDC grid connection

    Energy Technology Data Exchange (ETDEWEB)

    Weigel, Stefan; Weise, Bernd; Poeller, Markus [DIgSILENT GmbH, Gomaringen (Germany)

    2010-07-01

    This paper analyzes various aspects related to the operation of HVDC connected offshore wind farms. The main interest is on the behavior during on- and offshore faults. Different control strategies for VSC-HVDC and ''classical'' thyristor-based HVDC links are presented and analyzed via network simulations. Wind generators with fully-rated converters and wind generators with doubly-fed induction generators are considered as generator types. The feasibility, advantages and disadvantages of the various options are discussed in detail. (orig.)

  10. Review of fault diagnosis and fault-tolerant control for modular multilevel converter of HVDC

    DEFF Research Database (Denmark)

    Liu, Hui; Loh, Poh Chiang; Blaabjerg, Frede

    2013-01-01

    This review focuses on faults in Modular Multilevel Converter (MMC) for use in high voltage direct current (HVDC) systems by analyzing the vulnerable spots and failure mechanism from device to system and illustrating the control & protection methods under failure condition. At the beginning......, several typical topologies of MMC-HVDC systems are presented. Then fault types such as capacitor voltage unbalance, unbalance between upper and lower arm voltage are analyzed and the corresponding fault detection and diagnosis approaches are explained. In addition, more attention is dedicated to control...

  11. Hybrid simulation methods to perform grid integration studies for large scale offshore wind power connected through VSC-HVDC

    NARCIS (Netherlands)

    Meer, van der A.A.; Hendriks, R.L.; Gibescu, M.; Ferreira, J.A.; Kling, W.L.

    2011-01-01

    This paper deals with the inclusion of VSC-HVdc transmission schemes into stability-type simulations by hybrid methods. These methods allow selected parts of the network to be simulated in detail by including electro-magnetic behaviour of devices and network elements whereas the remainder of the

  12. Research on Robust Control Strategies for VSC-HVDC

    Science.gov (United States)

    Zhu, Kaicheng; Bao, Hai

    2018-01-01

    In the control system of VSC-HVDC, the phase locked loop provides phase signals to voltage vector control and trigger pulses to generate the required reference phase. The PLL is a typical second-order system. When the system is in unstable state, it will oscillate, make the trigger angle shift, produce harmonic, and make active power and reactive power coupled. Thus, considering the external disturbances introduced by the PLL in VSC-HVDC control system, the parameter perturbations of the controller and the model uncertainties, a H∞ robust controller of mixed sensitivity optimization problem is designed by using the Hinf function provided by the robust control toolbox. Then, compare it with the proportional integral controller through the MATLAB simulation experiment. By contrast, when the H∞ robust controller is added, active and reactive power of the converter station can track the change of reference values more accurately and quickly, and reduce overshoot. When the step change of active and reactive power occurs, mutual influence is reduced and better independent regulation is achieved.

  13. Recent advances in numerical solution of ionized fields associated with unipolar HVDC transmission lines in the presence of wind

    International Nuclear Information System (INIS)

    Li, X.; Raghuveer, M.R.; Ciric, I.R.

    1997-01-01

    Three finite element numerical algorithms were developed for solving the ionized field of unipolar HVDC transmission lines in the presence of wind. The solution of the ionized field was derived by transforming the boundary value problem to an optimization problem. The Gaussian iterative method was used for all three algorithms. The main features of each algorithm were presented and compared. The advantage of the first algorithm is that there is no need to assume the space charge density to be uniform on the conductor surface and therefore it is flexible in dealing with a complicated geometry like that of a bundled conductor. The main features of the other two algorithms were their ability to perform better with increase in wind velocity. Algorithm No. 2 was better than algorithm No. 1 in terms of storage and computational time. Algorithm No. 3 also had the advantage of using a triangular fine volume method which allowed computations to proceed faster. 11 refs., 10 figs

  14. HVDC Ground Electrodes and Tectonic Setting

    Science.gov (United States)

    Freire, P. F.; Pereira, S. Y.

    2017-12-01

    Ground electrodes in HVDC transmission are huge grounding systems for the DC part of the converter substation, about 1 km wide, sized to inject in the ground DC currents up to 3.5 kA. This work presents an analysis of how the tectonic setting at converter substation location is determinant for the search of the best electrode location (Site Selection) and on its design and performance. It will briefly present the author experience on HVDC electrode design, summarized as follows: Itaipu - Foz do Iguaçu electrodes (transmitter side) located in the middle of Paraná Sedimentary Basin, and Ibiúna electrodes (receiving side) on the border of the basin, 6 km from the geological strike, where the crystalline basement outcrops in São Paulo state; Madeira River - North electrodes (transmitting side) located on the Northwest border of South Amazon Craton, where the crystalline basement is below a shallow sediments layer, and South electrodes (receiving side) located within Paraná Sedimentary Basin; Chile - electrodes located on the Andean forearc, where the Nazca Plate plunges under the South American Plate; Kenya - Ethiopia - electrodes located in the African Rift; Belo Monte - North electrodes (transmitter side) located within the Amazonian Sedimentary Basin, about 35 km of its South border, and South electrodes (receiving side) within Paraná Sedimentary Basin (bipole 1) and on crystalline metamorphic terrain "Brasília Belt" (bipole 2). This diversity of geological conditions results on ground electrodes of different topologies and dimensions, with quite different electrical and thermal performances. A brief study of the geology of the converter stations regions, the so-called Desktop Study, allows for the preview of several important parameters for the site selection and design of the electrodes, such as localization, type, size and estimate of the interference area, which are important predictors of the investment to be made and indications of the design to be

  15. A generic inertia emulation controller for multi-terminal VSC-HVDC systems

    DEFF Research Database (Denmark)

    Zhu, Jiebei; Guerrero, Josep M.; Booth, Campbell

    2013-01-01

    A generic Inertia Emulation Controller (INEC) for Multi-Terminal Voltage-source-converter based HVDC (VSC-MTDC) is proposed in this paper. The proposed INEC can be incorporated in any grid-side-voltage-source-converter (GVSC) station, allowing the MTDC terminal to contribute an inertial response...

  16. Grid Integration of Offshore Wind Farms via VSC-HVDC – Dynamic Stability Study

    DEFF Research Database (Denmark)

    Liu, Hongzhi

    farms could seriously impact the operation and stability of their interconnected power system. To assist in maintaining the power system stability when large disturbances occur in the grid, modern offshore wind farms consisting of variable-speed wind turbines are required to provide ancillary services...... such as voltage and frequency control. The greater distance to shore makes commonly used high voltage AC (HVAC) connection unsuitable economically and technically for large offshore wind farms. Alternatively, voltage source converter (VSC)-based high voltage DC (HVDC) transmission becomes more attractive...... and practical to integrate large-scale offshore wind farms into the onshore power grid, owing to its high capacity, advanced controllability and stabilization potential for AC networks etc. In this dissertation, some of the key technical issues with grid integration of large-scale offshore wind farms via VSC...

  17. Assessment of environmental impact of HVDC power lines in terms of corona currents

    International Nuclear Information System (INIS)

    Tikhodeev, N.N.

    1997-01-01

    Corona loss measurements were made on a HVDC power transmission line to evaluate current density. Ion currents were obtained from unipolar and bipolar 400 to 1000 kV DC test lines. A numerical solution was proposed for assessing the maximum current density of unipolar corona currents near the lines. A larger ground clearance of line conductors was proposed as being the most effective way of lowering the current density. 11 refs., 2 tabs., 4 figs

  18. Integration of the work management of a HVDC overlay grid into the line-frequency control of a three-phase current integrated nework; Integration der Betriebsfuehrung eines HGUe-Overlay-Netzes in die Leitungs-Frequenz-Regelung eines Drehstrom-Verbundnetzes

    Energy Technology Data Exchange (ETDEWEB)

    Marten, Anne-Katrin

    2012-07-01

    To reduce emission of carbon dioxide the proportion of renewable energies is rapidly growing in German and European grids in general. Additionally, the bulk of them are generated in only a few spots in European transmission grid, whereas conventional power plants will shut down and the load center distribution will still be decentralized. This results in the need of a new and powerful transmission grid, which is able to transport bulk power over long distances. To overcome this challenge one of the discussed solutions for Europe is an Overlay Network based on HVDC technology connecting spots of bulk renewable energy plants and important load centers. Because of different performance compared to an ac grid, it is necessary for an HVDC Overlay Network to actively sustain system services such as power frequency control to ensure system stability and power quality as well as the ac grid does. A novel method for realizing participation of a HVDC Overlay Network in power frequency control is presented. It hasn't only an advantage for load frequency power flows, but also for contracted balancing power flows which are also feed via the dc grid pro rata. Numerical case studies are made to show some benefits of this method in case of various disturbances. It is shown that a HVDC Overlay Network with the developed operating control releases the ac grid by an adjustable amount of power flows and improves the power frequency control for example in terms of promptness and lower frequency deviations.

  19. Disturbance Attenuation of DC Voltage Droop Control Structures in a Multi-Terminal HVDC Grid

    DEFF Research Database (Denmark)

    Thams, Florian; Chatzivasileiadis, Spyros; Prieto-Araujo, Eduardo

    2017-01-01

    DC voltage droop control is seen as the preferred control structure for primary voltage control of future multiterminal HVDC systems. Different droop control structures have been proposed in literature which can be classified in eight categories. This paper contributes to an analysis of the distu......DC voltage droop control is seen as the preferred control structure for primary voltage control of future multiterminal HVDC systems. Different droop control structures have been proposed in literature which can be classified in eight categories. This paper contributes to an analysis...

  20. Integral Plus Resonant Sliding Mode Direct Power Control for VSC-HVDC Systems under Unbalanced Grid Voltage Conditions

    Directory of Open Access Journals (Sweden)

    Weipeng Yang

    2017-10-01

    Full Text Available An integral plus resonant sliding mode direct power control (IRSMC DPC strategy for voltage source converter high voltage direct current (VSC-HVDC systems under unbalanced grid voltage conditions is proposed in this paper. Through detailed instantaneous power flow analysis, a generalized power compensation method, by which the ratio between the amplitude of active and reactive power ripples can be controlled continuously, is obtained. This enables the system to provide flexible power control, so that the desired performance of the system on both the ac and dc sides can be attained under different operating conditions. When the grid voltage is unbalanced, one or both of the active and reactive power terms contain ripples, oscillating at twice the grid frequency, to obtain non-distorted ac current. A power controller consisting of the proportional, integral and resonant control laws is designed using the sliding mode control approach, to achieve accurate power control objective. Simulation studies on a two-terminal VSC-HVDC system using MATLAB/SIMULINK (R2013b, Mathworks, Natick, MA, USA are conducted to verify the effectiveness of the IRSMC DPC strategy. The results show that this strategy ensures satisfactory performance of the system over a wide range of operating conditions.

  1. Offshore windfarm connection with low frequency AC transmission technology

    DEFF Research Database (Denmark)

    Qin, Nan; Xu, Zhao; You, Shi

    2009-01-01

    This paper investigates the feasibility of using the low frequency AC transmission (LFAC) system, e.g. fraction of 50 Hz or 60 Hz, for connecting the large offshore wind farm to the grid by modelling and simulation. The LFAC system improves the transmission capacity and distance compared...... to the conventional AC solution at the nominal frequency, e.g. 50 Hz or 60 Hz. and reduces the investment cost compared to the HVDC solution. It is estimated that the LFAC system is competitive in the transmission distance of about 30-150 km. The simulation model of the wind integration using the LFAC system has been...... developed, which consists of three parts, the fixed-speed wind turbine representing a wind farm, the transmission line and the frequency converter. Although the transmission capability is greatly improved by the LFAC system, simulation shows it gives negative influences on the wind turbine operation due...

  2. 75 FR 10229 - Application for Presidential Permit; Champlain Hudson Power Express, Inc.

    Science.gov (United States)

    2010-03-05

    ... current (HVDC) electric transmission line that will originate at an HVDC converter station in Quebec... project (the ``Project'') would be a 2,000- megawatt (MW) HVDC Voltage Source Converter (VSC) controllable transmission system, comprising two 1,000-MW HVDC bipoles, each of which would include two submarine or...

  3. Modeling of Pressure Effects in HVDC Cables

    DEFF Research Database (Denmark)

    Szabo, Peter; Hassager, Ole; Strøbech, Esben

    1999-01-01

    A model is developed for the prediction of pressure effects in HVDC mass impregnatedcables as a result of temperature changes.To test the model assumptions, experiments were performed in cable like geometries.It is concluded that the model may predict the formation of gas cavities.......A model is developed for the prediction of pressure effects in HVDC mass impregnatedcables as a result of temperature changes.To test the model assumptions, experiments were performed in cable like geometries.It is concluded that the model may predict the formation of gas cavities....

  4. Asymmetrical Fault Analysis at the Offshore Network of HVDC connected Wind Power Plants

    DEFF Research Database (Denmark)

    Goksu, Omer; Cutululis, Nicolaos Antonio; Sorensen, Poul

    2017-01-01

    Short-circuit faults for HVDC connected Wind Power Plants (WPPs) have been studied mostly for dc link and onshore ac grid faults, while the offshore ac faults, especially asymmetrical faults, have been mostly omitted in the literature. Requirements related to the offshore asymmetrical faults have...... been kept as future development at national levels in the recent ENTSO-E HVDC network code. In this paper offshore ac faults are studied using the classical power system fault analysis methods. It is shown that suppression of negative sequence current flow is not applicable and negative sequence...

  5. Wind turbines and transmission systems for offshore wind projects in planning stage

    Energy Technology Data Exchange (ETDEWEB)

    Madariaga, Ander; Martin, Jose Luis; Martinez de Alegria, Inigo; Zamora, Inmaculada [University of the Basque Country (UPV/EHU), Bilbao (Spain). Engineering Faculty; Ceballos, Salvador [Parque Tecnologico de Bizkaia, Derio (Spain). Tecnalia Research and Innovation

    2012-07-01

    This paper reviews the current situation of the offshore wind turbines (OWTs) and the transmission systems (TSs) for offshore wind projects in the planning stage. Bearing in mind that offshore wind projects can last between seven and ten years from the first environmental studies to the commissioning, research engineers from companies and academia consider the solutions already available, but also to the new proposals expected to be ready in time for the project under consideration. Regarding the wind energy conversion systems (WECSs) installed in the OWTs, their main characteristics are reviewed considering turbines in the 4.1 to 10.0 MW range. Regarding the TSs, the current situation of point-to-point HVAC and HVDC links is presented, as well as some ideas related to future DC grids currently under study. (orig.)

  6. Control System interaction in the VSC-HVDC Grid Connected Offshore Wind Power Plant

    DEFF Research Database (Denmark)

    Glasdam, Jakob Bærholm; Kocewiak, Łukasz Hubert; Hjerrild, Jesper

    2015-01-01

    the source of the instability has been identified and mitigation methods have been designed and implemented. This procedure is not straightforward and can have a long lead time. The harmonic instability can have severe economic consequences for the OWPP owner due to the large investment. Harmonic stability...... the procedure of the stability study and its application for the HVDC grid connected OWPPs. The purpose of this paper is to investigate the harmonic instability phenomena in HVDC grid connected OWPPs using both frequency and time domain simulations. A good correlation at lower frequencies between the two......Conventional offshore wind power plants (OWPPs) are due to the combination of the extensive sub-marine cabling and possible low available short-circuit power at the point of common connection (PCC) susceptible to the harmonic instability phenomena. The instability is caused by the resonances...

  7. Harmonics in Offshore Wind Power Plants Employing Power Electronic Devices in the Transmission System

    DEFF Research Database (Denmark)

    Glasdam, Jakob Bærholm

    Introduction The trend in power generation is to partly replace conventional power plants with renewable energy sources. Offshore wind power has been selected to take up a significant proportion of the renewable energy production. The grid codes have been updated to accommodate the rising share...... of wind power. The onshore as well as offshore wind power plants (OWPPs) therefore have to meet the same stringent requirement as the conventional power plants. This can be accommodated by employment of flexible alternating current transmission system (FACTS) devices, such as the static compensator...... gives rise to a number of challenges to the wind power industry with regard to construction, installation as well as transmission of the generated energy. The STATCOM and the voltage-sourced converter high-voltage direct current (VSC-HVDC) are attractive solutions for grid connection of remotely located...

  8. Fault Ride Through Enhancement of VSC‐HVDC Connected Offshore Wind Power Plants

    DEFF Research Database (Denmark)

    Sharma, Ranjan; Wu, Qiuwei; Jensen, Kim Høj

    2018-01-01

    the model of a VSC‐HVDC‐connected offshore wind power plant (WPP) with an external grid. It proposes a feedforward DC voltage control based FRT technique to control the AC voltage at the WPP collector network during grid‐side faults. Time‐domain simulations have been used to verify the efficacy......Voltage source converter‐high voltage direct current (VSC‐HVDC) connections have become a new trend for long‐distance offshore wind power transmission. In order to facilitate the derivation of the feedforward DC voltage control based fault ride through (FRT) technique, this chapter describes...... of the proposed feedforward DC voltage control based FRT technique for VSC‐HVDC‐connected WPPs. Time‐domain simulation results shows that the proposed FRT scheme can successfully enable VSC‐HVDC‐connected WPPs to ride through balanced and unbalanced faults in host power systems, as well as faults in the WPP...

  9. Small-Signal Dynamic Analysis of LCC-HVDC with STATCOM at the Inverter Busbar

    Science.gov (United States)

    Liu, Dong; Jiang, Wen; Guo, Chunyi; Rehman, Atiq Ur; Zhao, Chengyong

    2018-01-01

    This paper develops a linearized small-signal dynamic model of a Line-Commutated-Converter based HVDC (LCC-HVDC) system with STATCOM at the inverter busbar, and validates its accuracy by comparing time-domain responses from small-signal model and PSCAD-based simulation results. Considering the potential impact of Phase-Locked-Loop (PLL) parameters on the study system and the close connection of STATCOM and LCC inverter station at AC busbar, this paper investigates the impact of PLL gains and AC voltage control parameters of STATCOM on the system small-signal stability. The studies show that (i) the PLL gain has highly impact on the study system and smaller PLL gains are preferable; (ii) larger values of both the proportional gain and the integral gain of AC voltage controller of STATCOM could result in oscillation/instability of the system.

  10. Generic Models of Wind Turbine Generators for Advanced Applications in a VSC-based Offshore HVDC Network

    DEFF Research Database (Denmark)

    Zeni, Lorenzo; Margaris, Ioannis; Hansen, Anca Daniela

    This paper focuses on generic Type 4 wind turbine generators models, their applicability in modern HVDC connections and their capability to provide advanced ancillary services therefrom. A point-to-point HVDC offshore connection is considered. Issues concerning coordinated HVDC and wind farm...... involving the HVDC converters- The performance against frequency disturbances of the two presented configurations is assessed and discussed by means of simulations....

  11. Power Hardware In The Loop Validation of Fault Ride Through of VSC HVDC Connected Offshore Wind Power Plants

    DEFF Research Database (Denmark)

    Sharma, Ranjan; Wu, Qiuwei; Cha, Seung-Tae

    2014-01-01

    This paper presents the power hardware in the loop (PHIL) validation of a feed forward DC voltage control scheme for the fault ride through (FTR) of voltage source converter (VSC) high voltage DC (HVDC) connected offshore wind power plants (WPPs). In the proposed FRT scheme, the WPP collector...... network AC voltage is actively controlled by considering both the DC voltage error and the AC current from the WPP AC collector system which ensures fast and robust FRT of the VSC HVDC connected offshore WPPs. The PHIL tests were carried out in order to verify the efficacy of the proposed feed forward DC...... voltage control scheme for enhancing the FRT capability of the VSC HVDC connected WPPs. The PHIL test results have demonstrated the proper control coordination between the offshore WPP and the WPP side VSC and the efficient FRT of the VSC HVDC connected WPPs....

  12. Highly efficient solutions for smart and bulk power transmission of 'green energy'

    Energy Technology Data Exchange (ETDEWEB)

    Breuer, Wilfried; Retzmann, Dietmar; Uecker, Karl

    2010-09-15

    Environmental constraints, loss minimization and CO2 reduction will play an increasingly more important role in future. Security and sustainability of power supply as well as economic efficiency needs application of advanced technologies. Innovative solutions with HVDC (High Voltage Direct Current) and FACTS (Flexible AC Transmission Systems) have the potential to cope with these challenges. They provide the features which are necessary to avoid technical problems in power systems, they increase the transmission capacity and system stability very efficiently and help prevent cascading outages. Furthermore, they are essential for Grid Access of Renewable Energy Sources such as Hydro, Wind and Solar-Energy.

  13. Finite element modelling of ionized field quantities around a monopolar HVDC transmission line

    International Nuclear Information System (INIS)

    Jaiswal, Vinay; Thomas, M Joy

    2003-01-01

    In this paper, the Poisson's equation describing the ionized field around an HVDC line is solved using an improved finite element based technique. First order isoparametric quadrilateral elements, together with a modified updating criterion for the space charge distribution, are implemented in the iterative procedure. A novel technique is presented for mesh generation in the presence of space charges. Electric field lines and equipotential lines have been computed using the proposed technique. Total corona current at different applied voltages above corona onset voltage, electric field at the ground plane with and without the presence of space charges and current density at the ground plane have also been computed. The results are in agreement with the experimental values available in the published literature

  14. Southern Alberta system reinforcement

    Energy Technology Data Exchange (ETDEWEB)

    Rehman, A. [Alberta Electric System Operator, Calgary, AB (Canada)

    2008-07-01

    System planning for the Alberta Electric System Operator's (AESO) southern system was discussed in view of the growing interest in developing wind energy resources in the province. While Alberta currently has a total of 11,500 MW of installed wind power, southern Alberta has a very small capability for interconnecting additional wind resources. There are 3 main agencies involved in system planning for the southern region: (1) the Alberta Utilities Commission (AUC), (2) the AESO, and (3) the transmission facility owners. Transmission needs are studied by the AESO, who then applies to the AUC for approval. Transmission facility owners also apply to the AUC for approval to construct facilities. The AESO's roles are to operate the wholesale electricity market; plan the transmission system; arrange access for loads and generation; and oversee transmission system operation. The AESO is an independent agency with a public interest mandate. The AESO's queue management process has been designed to facilitate non-discriminatory system access. Development options currently being considered by the AESO include a 240 kV AC transmission line; a 500 kV AC transmission line; a 765 kV AC transmission line; a high voltage direct current (HVDC) system; and a voltage source converter (VSC) HVDC system. Radial and looped configurations are also being considered. The AESO is currently conducting a participant involvement program that involves open houses with the Canadian Wind Energy Association (CanWEA) and other provincial stakeholders. tabs., figs.

  15. Control and operation of wind turbine converters during faults in an offshore wind power plant grid with VSC-HVDC connection

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay; Teodorescu, Remus; Rodriguez, Pedro

    2011-01-01

    Voltage source converter (VSC) based high voltage dc (HVDC) transmission is an attractive technique for large offshore wind power plants, especially when long cable transmission is required for connection to the onshore grid. New multi-MW wind turbines are likely to be equipped with full scale...... converters to meet the stringent grid code requirements. In such a scenario, the offshore grid is terminated to the power electronic converters on all the ends. This paper presents a control scheme for the synchronization and control of the grid side converters (GSC) of the wind turbine generators (WTG......). Current limit control enables the GSC to sustain the fault currents during short circuits in the offshore wind collector system grid. However, power transmission is affected, and the fault has to be isolated. It can be resynchronized after the fault has been cleared and the breaker reclosed. Healthy WTG...

  16. Integration of a finite element generator model into a simulated HVDC connected system

    Energy Technology Data Exchange (ETDEWEB)

    Preston, T W; Sturgess, J P [GEC Alsthom Engineering Research Center, Stafford (United Kingdom)

    1994-12-31

    Within most system analysis programs generators and motors are represented by an equivalent circuit model either a 2-axis model for both stators and rotor or a three-phase model of the stator and a two-axis model of the rotor. This may be adequate under certain operating conditions such as steady-state or some symmetrical faults but for inverter-fed motors or generators feeding into a rectified load a more rigorous model of the machine is required. This paper describes the theory and development of such a model, its integration with the power electronics and application to 6-pulse and 12-pulse converters, the latter being appropriate in systems similar to HVDC unit connection. (author) 5 refs., 16 figs.

  17. DC Voltage Droop Control Structures and its Impact on the Interaction Modes in Interconnected AC-HVDC Systems

    DEFF Research Database (Denmark)

    Thams, Florian; Chatzivasileiadis, Spyros; Eriksson, Robert

    2017-01-01

    Different dc voltage droop control structures for future multi-terminal HVDC systems have been proposed in literature. This paper contributes to the evaluation of those structures by an analysis of their impact on the coupling of the interconnected subsystems. In particular, the modes...... of the systems are classified in different subsets according to the participation of the various subsystems. Those subsets are then evaluated qualitatively and quantitatively indicating which impact the choice of the droop control structure has on the degree of coupling between the connected ac and dc systems...

  18. HVDC Connected Offshore Wind Power Plants: Review and Outlook of Current Research

    DEFF Research Database (Denmark)

    Glasdam, Jakob; Zeni, Lorenzo; Gryning, Mikkel

    2013-01-01

    This paper presents a state-of-the-art review on grid integration of large offshore wind power plants (OWPPs) using high voltage direct voltage (HVDC) for grid connection. The paper describes in detail selected challenges hereto and presents how DONG Energy Wind Power (DEWP) is addressing...... these challenges through three coordinated PhD projects in close collaboration with leading academia within the field. The overall goal of these projects is to acquire in-depth knowledge of relevant operating phenomena in the offshore OWPP grid, rich with power electronics devices (PEDs) such as the HVDC...... and the PED widely used in the wind turbine generators (WTGs). Challenges hereto include PED control system interaction (from a stability point of view), assessment of the quality of vendor supplied control systems and their robustness against e.g. short circuits and load rejection. Furthermore, the outcome...

  19. Method and system for a gas tube-based current source high voltage direct current transmission system

    Science.gov (United States)

    She, Xu; Chokhawala, Rahul Shantilal; Bray, James William; Sommerer, Timothy John; Zhou, Rui; Zhang, Di

    2017-08-29

    A high-voltage direct-current (HVDC) transmission system includes an alternating current (AC) electrical source and a power converter channel that includes an AC-DC converter electrically coupled to the electrical source and a DC-AC inverter electrically coupled to the AC-DC converter. The AC-DC converter and the DC-AC inverter each include a plurality of legs that includes at least one switching device. The power converter channel further includes a commutating circuit communicatively coupled to one or more switching devices. The commutating circuit is configured to "switch on" one of the switching devices during a first portion of a cycle of the H-bridge switching circuits and "switch off" the switching device during a second portion of the cycle of the first and second H-bridge switching circuits.

  20. Surface Layer Fluorination-Modulated Space Charge Behaviors in HVDC Cable Accessory

    Directory of Open Access Journals (Sweden)

    Jin Li

    2018-05-01

    Full Text Available Space charges tend to accumulate on the surface and at the interface of ethylene–propylene–diene terpolymer (EPDM, serving as high voltage direct current (HVDC cable accessory insulation, which likely induces electrical field distortion and dielectric breakdown. Direct fluorination is an effective method to modify the surface characteristics of the EPDM without altering the bulk properties too much. In this paper, the surface morphology, hydrophobic properties, relative permittivity, and DC conductivity of the EPDM before and after fluorination treatment were tested. Furthermore, the surface and interface charge behaviors in the HVDC cable accessory were investigated by the pulsed electroacoustic (PEA method, and explained from the point of view of trap distribution. The results show that fluorination helps the EPDM polymer obtain lower surface energy and relative permittivity, which is beneficial to the interface match in composite insulation systems. The lowest degree of space charge accumulation occurs in EPDM with 30 min of fluorination. After analyzing the results of the 3D potentials and the density of states (DOS behaviors in EPDM before and after fluorination, it can be found that fluorination treatment introduces shallower electron traps, and the special electrostatic potential after fluorination can significantly suppress the space charge accumulation at the interface in the HVDC cable accessory.

  1. Models and methods for assessing the value of HVDC and MVDC technologies in modern power grids

    Energy Technology Data Exchange (ETDEWEB)

    Makarov, Yuri V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Elizondo, Marcelo A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); O' Brien, James G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Huang, Qiuhua [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kirkham, Harold [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Huang, Zhenyu [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chinthavali, Madhu [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Suman, Debnath [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Mohan, Nihal [Mid-Continent Independent System Operator (MISO), St. Paul, MN (United States); Hess, Warren [Mid-Continent Independent System Operator (MISO), St. Paul, MN (United States); Duebner, David [Mid-Continent Independent System Operator (MISO), St. Paul, MN (United States); Orser, David [Mid-Continent Independent System Operator (MISO), St. Paul, MN (United States); Brown, Hilary [Mid-Continent Independent System Operator (MISO), St. Paul, MN (United States); Osborn, Dale [Mid-Continent Independent System Operator (MISO), St. Paul, MN (United States); Feltes, James [Siemens, Knoxville, TN (United States); Kurthakoti Chandrashekhara, Divya [Siemens, Knoxville, TN (United States); Zhu, Wenchun [Siemens, Knoxville, TN (United States)

    2017-07-31

    This report reflects the results of U.S. Department of Energy’s (DOE) Grid Modernization project 0074 “Models and methods for assessing the value of HVDC [high-voltage direct current] and MTDC [multi-terminal direct current] technologies in modern power grids.” The work was done by the Pacific Northwest National Laboratory (PNNL) and Oak Ridge National Laboratory (ORNL) in cooperation with Mid-Continent Independent System Operator (MISO) and Siemens. The main motivation of this study was to show the benefit of using direct current (DC) systems larger than those in existence today as they overlap with the alternating current (AC) systems. Proper use of their flexibility in terms of active/reactive power control and fast response can provide much-needed services to the grid at the same time as moving large blocks of energy to take advantage of cost diversity. Ultimately, the project’s success will enable decision-makers and investors to make well-informed decisions regarding this use of DC systems. This project showed the technical feasibility of HVDC macrogrid for frequency control and congestion relief in addition to bulk power transfers. Industry-established models for commonly used technologies were employed, along with high-fidelity models for recently developed HVDC converter technologies; like the modular multilevel converters (MMCs), a voltage source converters (VSC). Models for General Electric Positive Sequence Load Flow (GE PSLF) and Siemens Power System Simulator (PSS/E), widely used analysis programs, were for the first time adapted to include at the same time both Western Electricity Coordinating Council (WECC) and Eastern Interconnection (EI), the two largest North American interconnections. The high-fidelity models and their control were developed in detail for MMC system and extended to HVDC systems in point-to-point and in three-node multi-terminal configurations. Using a continental-level mixed AC-DC grid model, and using a HVDC macrogrid

  2. High Voltage Power Transmission for Wind Energy

    Science.gov (United States)

    Kim, Young il

    The high wind speeds and wide available area at sea have recently increased the interests on offshore wind farms in the U.S.A. As offshore wind farms become larger and are placed further from the shore, the power transmission to the onshore grid becomes a key feature. Power transmission of the offshore wind farm, in which good wind conditions and a larger installation area than an onshore site are available, requires the use of submarine cable systems. Therefore, an underground power cable system requires unique design and installation challenges not found in the overhead power cable environment. This paper presents analysis about the benefit and drawbacks of three different transmission solutions: HVAC, LCC/VSC HVDC in the grid connecting offshore wind farms and also analyzed the electrical characteristics of underground cables. In particular, loss of HV (High Voltage) subsea power of the transmission cables was evaluated by the Brakelmann's theory, taking into account the distributions of current and temperature.

  3. Highly efficient solutions for smart and bulk power transmission of 'green energy'

    Energy Technology Data Exchange (ETDEWEB)

    Breuer, Wilfried; Retzmann, Dietmar; Uecker, Karl

    2010-09-15

    Environmental constraints, loss minimization and CO2 reduction will play an increasingly more important role in future. Security and sustainability of power supply as well as economic efficiency needs application of advanced technologies. Innovative solutions with HVDC (High Voltage Direct Current) and FACTS (Flexible AC Transmission Systems) have the potential to cope with these challenges. They provide the features which are necessary to avoid technical problems in power systems, they increase the transmission capacity and system stability very efficiently and help prevent cascading outages. Furthermore, they are essential for Grid Access of Renewable Energy Sources such as Hydro, Wind and Solar-Energy.

  4. Adapting AC Lines to DC Grids for Large-Scale Renewable Power Transmission

    Directory of Open Access Journals (Sweden)

    D. Marene Larruskain

    2014-10-01

    Full Text Available All over the world, governments of different countries are nowadays promoting the use of clean energies in order to achieve sustainable energy systems. In this scenario, since the installed capacity is continuously increasing, renewable sources can play an important role. Notwithstanding that, some important problems may appear when connecting these sources to the grid, being the overload of distribution lines one of the most relevant. In fact, renewable generation is usually connected to the nearest AC grid, although this HV system may not have been designed considering distributed generation. In the particular case of large wind farms, the electrical grid has to transmit all the power generated by wind energy and, as a consequence, the AC system may get overloaded. It is therefore necessary to determine the impact of wind power transmission so that appropriate measures can be taken. Not only are these measures influenced by the amount of power transmitted, but also by the quality of the transmitted power, due to the output voltage fluctuation caused by the highly variable nature of wind. When designing a power grid, although AC systems are usually the most economical solution because of its highly proven technology, HVDC may arise in some cases (e.g. offshore wind farms as an interesting alternative, offering some added values such as lower losses and better controllability. This way, HVDC technology can solve most of the aforementioned problems and has a good potential for future use. Additionally, the fast development of power electronics based on new and powerful semiconductor devices allow the spread of innovative technologies, such as VSC-HVDC, which can be applied to create DC grids. This paper focuses on the main aspects involved in adapting the existing overhead AC lines to DC grids, with the objective of improving the transmission of distributed renewable energy to the centers of consumption.

  5. Simulation of the large-scale offshore-wind farms including HVDC-grid connections using the simulation tool VIAvento

    Energy Technology Data Exchange (ETDEWEB)

    Bartelt, R.; Heising, C.; Ni, B. [Avasition GmbH, Dortmund (Germany); Zadeh, M. Koochack; Lebioda, T.J.; Jung, J. [TenneT Offshore GmbH, Bayreuth (Germany)

    2012-07-01

    Within the framework of a research project the stability of the offshore grid especially in terms of sub-harmonic stability for the likely future extension stage of the offshore grids i.e. having parallel connection of two or more HVDC links and for certain operating scenarios e.g. overload scenario will be investigated. For this purpose, a comprehensive scenario-based assessment in time domain is unavoidable. Within this paper, the simulation tool VIAvento is briefly presented which allows for these comprehensive time-domain simulations taking the special characteristics of power-electronic assets into account. The core maxims of VIAvento are presented. Afterwards, the capability of VIAvento is demonstrated with simulation results of two wind farms linked via a HVDC grid connection system (160 converters and two HVDC stations in modular multilevel converter topology). (orig.)

  6. Dynamic Performance of an HVDC Link

    Directory of Open Access Journals (Sweden)

    S. A. ZIDI

    2005-09-01

    Full Text Available This paper presents the results of a simulation study on a 12 pulse HVDC (High Voltage Direct Current using a system in Matlab/Simulink. The object of the study is to investigate the steady state and dynamic performance of the system. First we examine response of current regulator after change in current reference in order to see the behavior of the controllers in controlling the desired current. Next, we present the digital simulation of a test system and show the response to a DC fault in the line and the AC fault at inverter side. The results are evaluated to enhance the recovery of the system from the disturbances for a full range of typical disturbances. The presented approach benefits from Simulink’s advantages in modeling and simulating dynamical systems.

  7. High-voltage direct-current circuit breakers

    International Nuclear Information System (INIS)

    Yoshioka, Y.; Hirasawa, K.

    1991-01-01

    This paper reports that in 1954 the first high-voltage direct-current (HVDC) transmission system was put into operation between Gotland and the mainland of Sweden. Its system voltage and capacity were 100 kV and 20 MW, respectively. Since then many HVDC transmission systems have been planned, constructed, or commissioned in more than 30 places worldwide, and their total capacity is close to 40 GW. Most systems commissioned to date are two-terminal schemes, and HVDC breakers are not yet used in the high-potential main circuit of those systems, because the system is expected to perform well using only converter/inverter control even at a fault stage of the transmission line. However, even in a two-terminal scheme there are not a few merits in using an HVDC breaker when the system has two parallel transmission lines, that is, when it is a double-circuit system

  8. Research on the Inductance/Capacitance Switch Model for an LCC-HVDC Converter in an AC/DC Hybrid Grid

    Directory of Open Access Journals (Sweden)

    Yangyang He

    2018-03-01

    Full Text Available In order to improve the simulation speed of the AC/DC hybrid grid, the inductance/capacitance (L/C switch model for line-commutated converter of high-voltage direct current (LCC-HVDC is presented in this study. The time domain modeling method is used to analyze the circuit of L/C switch model for the six-pulse system in LCC-HVDC in a switching period. A parameter setting method of L/C switch model is proposed considering the transient response, the steady state performance, switching losses and simulation error of the switch. The inductance/capacitance (L/C switch model for LCC-HVDC has the advantage of keeping the admittance matrix unchanged regardless of the change of switching state, which improves the simulation efficiency. Finally, the validity of the parameter setting method is verified. Compared with the test results of PSCAD/EMTDC, the accuracy of the proposed LCC-HVDC simulation model is proved. The model is suitable for real-time or offline simulation of AC/DC hybrid grid.

  9. Development of toroid-type HTS DC reactor series for HVDC system

    Science.gov (United States)

    Kim, Kwangmin; Go, Byeong-Soo; Park, Hea-chul; Kim, Sung-kyu; Kim, Seokho; Lee, Sangjin; Oh, Yunsang; Park, Minwon; Yu, In-Keun

    2015-11-01

    This paper describes design specifications and performance of a toroid-type high-temperature superconducting (HTS) DC reactor. The first phase operation targets of the HTS DC reactor were 400 mH and 400 A. The authors have developed a real HTS DC reactor system during the last three years. The HTS DC reactor was designed using 2G GdBCO HTS wires. The HTS coils of the toroid-type DC reactor magnet were made in the form of a D-shape. The electromagnetic performance of the toroid-type HTS DC reactor magnet was analyzed using the finite element method program. A conduction cooling method was adopted for reactor magnet cooling. The total system has been successfully developed and tested in connection with LCC type HVDC system. Now, the authors are studying a 400 mH, kA class toroid-type HTS DC reactor for the next phase research. The 1500 A class DC reactor system was designed using layered 13 mm GdBCO 2G HTS wire. The expected operating temperature is under 30 K. These fundamental data obtained through both works will usefully be applied to design a real toroid-type HTS DC reactor for grid application.

  10. Government support for hvdc research

    Energy Technology Data Exchange (ETDEWEB)

    1968-07-12

    To help secure a place for Britain in hvdc export market beyond the next decade, the Ministry of Technology is sponsoring. Research into thyristor converters as a replacement for the mercury arc valves now used in terminal equipment. English Electric has secured from Mintech a risk sharing contract contributing nearly 250,000 pounds towards the cost of a development program.

  11. Transporte de energía eléctrica en corriente contínua. Enlaces HVDC-VSC

    OpenAIRE

    Monterrubio Díez, Mario

    2013-01-01

    El proyecto fin de carrera se plantea como un estudio de la tecnología HVDC-VSC, por su carácter novedoso y reciente implantación en los sistemas de transporte de electricidad. Con este trabajo se pretende dar a conocer de modo general la tecnología HVDC y de manera particular la variante HVDC-VSC. Departamento de Ingeniería Eléctrica Ingeniero Técnico Industrial, Especialidad en Electricidad

  12. Droop Control Design of Multi-VSC Systems for Offshore Networks to Integrate Wind Energy

    Directory of Open Access Journals (Sweden)

    Muhammad Raza

    2016-10-01

    Full Text Available This research envisages the droop control design of multi voltage source converter systems for offshore networks to integrate wind power plant with the grids. An offshore AC network is formulated by connecting several nearby wind power plants together with AC cables. The net energy in the network is transferred to onshore using voltage source high voltage direct current (VSC-HVDC transmissionsystems. In the proposed configuration, an offshore network is energized by more than one VSC-HVDC system, hereby providing redundancy to continue operation in case of failure in one of the HVDC transmission lines. The power distribution between VSC-HVDC systems is done using a droop control scheme. Frequency droop is implemented to share active power, and voltage droop is implemented to share reactive power. Furthermore, a method of calculating droop gains according to the contribution factor of each converter is presented. The system has been analyzed to evaluate the voltage profile of the network affected by the droop control. Nonlinear dynamic simulation has been performed for the verification of the control principle.

  13. Total Magnetic Field Signatures over Submarine HVDC Power Cables

    Science.gov (United States)

    Johnson, R. M.; Tchernychev, M.; Johnston, J. M.; Tryggestad, J.

    2013-12-01

    Mikhail Tchernychev, Geometrics, Inc. Ross Johnson, Geometrics, Inc. Jeff Johnston, Geometrics, Inc. High Voltage Direct Current (HVDC) technology is widely used to transmit electrical power over considerable distances using submarine cables. The most commonly known examples are the HVDC cable between Italy and Greece (160 km), Victoria-Tasmania (300 km), New Jersey - Long Island (82 km) and the Transbay cable (Pittsburg, California - San-Francisco). These cables are inspected periodically and their location and burial depth verified. This inspection applies to live and idle cables; in particular a survey company could be required to locate pieces of a dead cable for subsequent removal from the sea floor. Most HVDC cables produce a constant magnetic field; therefore one of the possible survey tools would be Marine Total Field Magnetometer. We present mathematical expressions of the expected magnetic fields and compare them with fields observed during actual surveys. We also compare these anomalies fields with magnetic fields produced by other long objects, such as submarine pipelines The data processing techniques are discussed. There include the use of Analytic Signal and direct modeling of Total Magnetic Field. The Analytic Signal analysis can be adapted using ground truth where available, but the total field allows better discrimination of the cable parameters, in particular to distinguish between live and idle cable. Use of a Transverse Gradiometer (TVG) allows for easy discrimination between cable and pipe line objects. Considerable magnetic gradient is present in the case of a pipeline whereas there is less gradient for the DC power cable. Thus the TVG is used to validate assumptions made during the data interpretation process. Data obtained during the TVG surveys suggest that the magnetic field of a live HVDC cable is described by an expression for two infinite long wires carrying current in opposite directions.

  14. A coordinated multivariable control system design for a HVDC linked remote ABWR nuclear power park

    International Nuclear Information System (INIS)

    Hara, T.; Kurita, A.; Younkins, T.D.; Sanchez-Gasca, J.J.; Chow, J.H.

    1987-01-01

    This paper presents a conceptual design of a coordinated output feedback multivariable control system for a remote nuclear generation park connected to a load area with an HVDC link. The control design presented in this paper is for both normal operation (e.g., load following and frequency regulation) and contingencies (e.g., loss of a dc bipole or loss of two nuclear reactors). The design is simple and compact: four control signals, five measurements, and the integrals of two measurements are used to meet all the objectives and constraints for normal operation and contingencies. The multivariable control coordinates the measurements and controls according to the time frame of response and the amount of interactions between variables. This paper describes the model of the system, the multivariable control design, and the nonlinear time domain simulation of the overall system performance

  15. 'Take the long way down': Integration of large-scale North Sea wind using HVDC transmission

    International Nuclear Information System (INIS)

    Weigt, Hannes; Jeske, Till; Leuthold, Florian; Hirschhausen, Christian von

    2010-01-01

    We analyze the impact of extensive wind development in Germany for the year 2015, focusing on grid extensions and price signals. We apply the electricity generation and network model ELMOD to compare zonal, nodal, and uniform pricing approaches. In addition to a reference case of network extensions recommended by the German Energy Agency (Dena), we develop a scenario to transmit wind energy to major load centers in Western and Southern Germany via high-voltage direct current (HVDC) connections. From an economic-engineering standpoint, our results indicate that these connections are the most economic way to manage the integration of large-scale offshore wind resources, and that nodal pricing is most likely to determine the locales for future investment to eliminate congestion. We conclude with a description of the model's potential limitations.

  16. Study on electrochemical corrosion mechanism of steel foot of insulators for HVDC lines

    Science.gov (United States)

    Zheng, Weihua; Sun, Xiaoyu; Fan, Youping

    2017-09-01

    The main content of this paper is the mechanism of electrochemical corrosion of insulator steel foot in HVDC transmission line, and summarizes five commonly used artificial electrochemical corrosion accelerated test methods in the world. Various methods are analyzed and compared, and the simulation test of electrochemical corrosion of insulator steel feet is carried out by water jet method. The experimental results show that the experimental environment simulated by water jet method is close to the real environment. And the three suspension modes of insulators in the actual operation, the most serious corrosion of the V type suspension hardware, followed by the tension string suspension, and the linear string corrosion rate is the slowest.

  17. The integration of renewable energies into the German transmission grid—A scenario comparison

    International Nuclear Information System (INIS)

    Schroeder, Andreas; Oei, Pao-Yu; Sander, Aram; Hankel, Lisa; Laurisch, Lilian Charlotte

    2013-01-01

    This article presents a quantitative assessment of the need for electricity transmission capacity investments in Germany for 2030. Congestion is analyzed and its possible relief through appropriate grid reinforcements as those described in the Ten Year Network Development Plan (TYNDP) of the European Commission. Congestion is investigated in three scenarios which differ in the location of power resources and the line expansion projects accomplished. Results show that the TYNDP and overlay line projects proposed in 2011 are not sufficient measures to cope with the increasing demand for transmission capacity. The paper also concludes that if power generation resources are moved closer to demand centers grid bottlenecks can be partly relieved by 2030. The introduction of a high-voltage direct current (HVDC) backbone grid does not relieve congestion significantly. - Highlights: • The need for power transmission capacity in Germany for 2030 is assessed. • The TYNDP is insufficient to cope with increasing demand for transmission. • If generation is moved closer to demand grid bottlenecks are partly relieved. • An HVDC backbone grid does not relieve congestion significantly

  18. Method and system for a gas tube switch-based voltage source high voltage direct current transmission system

    Science.gov (United States)

    She, Xu; Chokhawala, Rahul Shantilal; Zhou, Rui; Zhang, Di; Sommerer, Timothy John; Bray, James William

    2016-12-13

    A voltage source converter based high-voltage direct-current (HVDC) transmission system includes a voltage source converter (VSC)-based power converter channel. The VSC-based power converter channel includes an AC-DC converter and a DC-AC inverter electrically coupled to the AC-DC converter. The AC-DC converter and a DC-AC inverter include at least one gas tube switching device coupled in electrical anti-parallel with a respective gas tube diode. The VSC-based power converter channel includes a commutating circuit communicatively coupled to one or more of the at least one gas tube switching devices. The commutating circuit is configured to "switch on" a respective one of the one or more gas tube switching devices during a first portion of an operational cycle and "switch off" the respective one of the one or more gas tube switching devices during a second portion of the operational cycle.

  19. Power-electronic asset characteristics for HVDC-connected offshore grids

    Energy Technology Data Exchange (ETDEWEB)

    Heising, C.; Meyer, D.; Bartelt, R. [Avasition GmbH, Dortmund (Germany); Koochack Zadeh, M.; Lebioda, T.J.; Jung, J. [TenneT Offshore GmbH, Bayreuth (Germany)

    2012-07-01

    Analysing offshore wind-farm applications as well as other converter-dominated grids, two key differences can be identified compared to conventional configurations: No relevant short-circuit power is available and no inertia is directly coupled to the AC grid. Within this paper, power-electronic asset characteristics for HVDC-connected offshore grids are presented which apply new principles allowing for better dynamic operation in the weak grids introduced. The capability is demonstrated using simulation results of an AC-multi-terminal system. (orig.)

  20. Power-Hardware-In-the-Loop (PHIL) Test of VSC-based HVDC connection for Offshore Wind Power Plants (WPPs)

    DEFF Research Database (Denmark)

    Sharma, Ranjan; Cha, Seung-Tae; Wu, Qiuwei

    2011-01-01

    This paper presents a power-hardware-in-the-loop (PHIL) test for an offshore wind power plant (WPP) interconnected to the onshore grid by a VSC-based HVDC connection. The intention of the PHIL test is to verify the control coordination between the plant side converter of the HVDC connection...... the successful control coordination between the WPP and the plant side VSC converter of the HVDC connection of the WPP....

  1. Tailored sPP/Silica Nanocomposite for Ecofriendly Insulation of Extruded HVDC Cable

    Directory of Open Access Journals (Sweden)

    Bin Dang

    2015-01-01

    Full Text Available Cross-linked polyethylene (XLPE is a thermosetting material that cannot be recycled at the end of its lifetime. This study investigated the potential of syndiotactic polypropylene (sPP/silica as an ecofriendly extruded insulation system for HVDC cables. We investigated the morphology, Fourier transform infrared, and thermal, thermomechanical, and electrical behaviors of sPP modified with 0.5–3% nanosilica. We found that the silica/sPP nanocomposite without cross-linking offered a suitable mechanical modulus at room temperature and sufficient intensity at high temperatures, and adding nanosilica modified by a silane coupling agent to the sPP resulted in significant DC resistivity and space charge improvement. The optimal nanosilica content in the sPP was determined by balancing the mechanical and thermomechanical characteristics and the DC resistivity. The sPP/silica nanocomposite reported here shows great potential as a candidate insulation material for future ecofriendly extruded HVDC cables.

  2. Protection of Multi-Terminal VSC-HVDC Grids Based on the Response of the First Carrier Frequency Harmonic Current

    DEFF Research Database (Denmark)

    Ashouri, Mani; Khazraj, Hesam; Silva, Filipe Miguel Faria da

    This paper investigates the response of first carrier frequency harmonic (FCFH) current for designing a protection algorithm for multi-terminal Voltage source converter-based HVDC (VSC-MTDC) transmission grids. This transient harmonic current has been used before, to discriminate external AC faults...... various kinds of faults with different locations and resistances. This paper will also consider half-bridge MMC instead of two-level VSCs to test the sensitivity of the FCFH based algorithm for lower harmonic values. A modified meshed version of CIGRE DC model has been used in PSCAD and the signal...

  3. 75 FR 34720 - Notice of Intent To Prepare an Environmental Impact Statement and To Conduct Public Scoping...

    Science.gov (United States)

    2010-06-18

    ...-voltage direct current (HVDC) Voltage Source Converter (VSC) controllable transmission system from the... HVDC bipoles. A bipole consists of two connected submarine or underground cables, one of which is... project would originate at an HVDC converter station near Hydro-Qu[eacute]bec Trans[Eacute]nergie's 765...

  4. IMPROVEMENT OF POWER SYSTEM QUALITY USING VSC ...

    African Journals Online (AJOL)

    The HVDC technology can be represented by the combination of a Direct Current (DC) circuit with two power electronics converters, each one at a link terminal, for AC/DC and DC/AC conversion The principal characteristic of VSC-HVDC transmission is its ability to independently control the reactive and real power flow at ...

  5. 77 FR 75623 - Notice of Intent To Prepare an Environmental Impact Statement for the Plains and Eastern Clean...

    Science.gov (United States)

    2012-12-21

    ... voltage direct current (HVDC) electric transmission system and associated facilities with the capacity to... project and supporting information. Clean Line's original proposal included two HVDC lines, each rated at..., Clean Line has modified its Section 1222 proposal to a single HVDC line with the capacity to deliver 3...

  6. Cluster Control of Offshore Wind Power Plants Connected to a Common HVDC Station

    DEFF Research Database (Denmark)

    Göksu, Ömer; Sakamuri, Jayachandra N.; Rapp, C. Andrea

    2016-01-01

    of offshore AC grid voltage control and onshore ancillary services provision, i.e. POD by the active power modulation of the cluster. The two cases are simulated using DIgSILENT PowerFactory, where the IEC 61400-27-1 wind turbine and WPP control models and a generic offshore layout with cluster of three WPPs......In this paper a coordinated control for cluster of offshore WPPs connected to the same HVDC connection is being implemented and analyzed. The study is targeting two cases as; coordination of reactive power flow between HVDC converter and the WPP cluster while providing offshore AC grid voltage...... control, and coordinated closed loop control between the HVDC and the WPPs while the cluster is providing Power Oscillation Damping ( POD) via active power modulation. It is shown that the coordinated cluster control helps to improve the steady-state and dynamic response of the offshore AC grid in case...

  7. Present trends in HVDC converter station design

    Energy Technology Data Exchange (ETDEWEB)

    Carlsson, Lennart; Asplund, Gunnar; Bjorklund, Hans; Flisberg, Gunnar [ABB Power Systems AB, Ludvika (Sweden)

    1994-12-31

    HVDC converter station technology has developed rapidly to satisfy increasing requirements during past 10 - 15 years, but there has not been any dramatic changes since thyristor valves were introduced in the mid 70s. This paper describes some recent and expected future developments, that will substantiality change and simplify future converter stations. (author) 4 refs., 7 figs.

  8. Wide area stability analysis and control of interconnected power systems with HVDC and FACTS devices

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yong

    2012-11-01

    In order to damp low-frequency oscillations and improve the overall stability of large-scale interconnected power systems, this book investigates the wide-area stability analysis and control methods from different perspectives. The flexible and fast control capability of high-voltage (FACTS) is investigated in detail to implement a wide-area measurement based damping control. A sequential and global mixed optimization method is proposed to simultaneously optimize local and wide area damping controllers. A wide-area robust coordination method is presented to coordinate multiple wide-area damping controllers (WADC). A delay-dependent robust design method is also proposed to handle time-varying delays commonly existing in wide-area signal communication. A closed-loop hardware experiment is used to validate the damping performance. The research activities of this book include power system stability analysis and control, wide-area damping control as well as HVDC and FACTS technologies.

  9. Electrical Power Supply to Offshore Oil Installations by High Voltage Direct Current Transmission

    Energy Technology Data Exchange (ETDEWEB)

    Myhre, Joergen Chr.

    2001-07-01

    This study was initiated to investigate if it could be feasible to supply offshore oil installations in the North Sea with electrical power from land. A prestudy of alternative converter topologies indicated that the most promising solution would be to investigate a conventional system with reduced synchronous compensator rating. The study starts with a summary of the state of power supply to offshore installations today, and a short review of classical HVDC transmission. It goes on to analyse how a passive network without sources influences the inverter. The transmission, with its current controlled rectifier and large inductance, is simulated as a current source. Under these circumstances the analysis shows that the network frequency has to adapt in order to keep the active and reactive power balance until the controllers are able to react. The concept of firing angle for a thyristor is limited in a system with variable frequency, the actual control parameter is the firing delay time. Sensitivity analysis showed some astonishing consequences. The frequency rises both by an increase in the active and in the reactive load. The voltage falls by an increase in the active load, but rises by an increase in the inductive load. Two different control principles for the system of inverter, synchronous compensator and load are defined. The first takes the reference for the firing delay time from the fundamental voltage at the point of common coupling. The second takes the reference for the firing delay time from the simulated EMF of the synchronous compensator. Of these, the second is the more stable and should be chosen as the basis for a possible control system. Two simulation tools are applied. The first is a quasi-phasor model running on Matlab with Simulink. The other is a time domain model in KREAN. The time domain model is primarily used for the verification of the quasi-phasor model, and shows that quasi-phasors is still a valuable tool for making a quick analysis

  10. A Case Study of Wind-PV-Thermal-Bundled AC/DC Power Transmission from a Weak AC Network

    Science.gov (United States)

    Xiao, H. W.; Du, W. J.; Wang, H. F.; Song, Y. T.; Wang, Q.; Ding, J.; Chen, D. Z.; Wei, W.

    2017-05-01

    Wind power generation and photovoltaic (PV) power generation bundled with the support by conventional thermal generation enables the generation controllable and more suitable for being sent over to remote load centre which are beneficial for the stability of weak sending end systems. Meanwhile, HVDC for long-distance power transmission is of many significant technique advantages. Hence the effects of wind-PV-thermal-bundled power transmission by AC/DC on power system have become an actively pursued research subject recently. Firstly, this paper introduces the technical merits and difficulties of wind-photovoltaic-thermal bundled power transmission by AC/DC systems in terms of meeting the requirement of large-scale renewable power transmission. Secondly, a system model which contains a weak wind-PV-thermal-bundled sending end system and a receiving end system in together with a parallel AC/DC interconnection transmission system is established. Finally, the significant impacts of several factors which includes the power transmission ratio between the DC and AC line, the distance between the sending end system and receiving end system, the penetration rate of wind power and the sending end system structure on system stability are studied.

  11. Brief analysis of Jiangsu grid security and stability based on multi-infeed DC index in power system

    Science.gov (United States)

    Zhang, Wenjia; Wang, Quanquan; Ge, Yi; Huang, Junhui; Chen, Zhengfang

    2018-02-01

    The impact of Multi-infeed HVDC has gradually increased to security and stability operating in Jiangsu power grid. In this paper, an appraisal method of Multi-infeed HVDC power grid security and stability is raised with Multi-Infeed Effective Short Circuit Ratio, Multi-Infeed Interaction Factor and Commutation Failure Immunity Index. These indices are adopted in security and stability simulating calculation of Jiangsu Multi-infeed HVDC system. The simulation results indicate that Jiangsu power grid is operating with a strong DC system. It has high level of power grid security and stability, and meet the safety running requirements. Jinpin-Suzhou DC system is located in the receiving end with huge capacity, which is easily leading to commutation failure of the transmission line. In order to resolve this problem, dynamic reactive power compensation can be applied in power grid near Jinpin-Suzhou DC system. Simulation result shows this method is feasible to commutation failure.

  12. Redundancy Determination of HVDC MMC Modules

    Directory of Open Access Journals (Sweden)

    Chanki Kim

    2015-08-01

    Full Text Available An availability and a reliability prediction has been made for a high-voltage direct-current (HVDC module of VSC (Voltage Source Converter containing DC/DC converter, gate driver, capacitor and insulated gate bipolar transistors (IGBT. This prediction was made using published failure rates for the electronic equipment. The purpose of this prediction is to determinate the additional module redundancy of VSC and the used method is “binomial failure method”.

  13. Tailored sPP/Silica Nano composite for Eco friendly Insulation of Extruded HVDC Cable

    International Nuclear Information System (INIS)

    Dang, B.; He, J.; Hu, J.; Zhou, Y.

    2015-01-01

    Cross-linked polyethylene (XLPE) is a thermosetting material that cannot be recycled at the end of its lifetime. This study investigated the potential of syndiotactic polypropylene (sPP)/silica as an eco friendly extruded insulation system for HVDC cables. We investigated the morphology, Fourier transform infrared, and thermal, thermomechanical, and electrical behaviors of sPP modified with 0.5-3% nano silica. We found that the silica/sPP nano composite without cross-linking offered a suitable mechanical modulus at room temperature and sufficient intensity at high temperatures, and adding nano silica modified by a silane coupling agent to the sPP resulted in significant DC resistivity and space charge improvement. The optimal nano silica content in the sPP was determined by balancing the mechanical and thermomechanical characteristics and the DC resistivity. The sPP/silica nano composite reported here shows great potential as a candidate insulation material for future eco friendly extruded HVDC cables.

  14. Hybrid AC-High Voltage DC Grid Stability and Controls

    Science.gov (United States)

    Yu, Jicheng

    The growth of energy demands in recent years has been increasing faster than the expansion of transmission facility construction. This tendency cooperating with the continuous investing on the renewable energy resources drives the research, development, and construction of HVDC projects to create a more reliable, affordable, and environmentally friendly power grid. Constructing the hybrid AC-HVDC grid is a significant move in the development of the HVDC techniques; the form of dc system is evolving from the point-to-point stand-alone dc links to the embedded HVDC system and the multi-terminal HVDC (MTDC) system. The MTDC is a solution for the renewable energy interconnections, and the MTDC grids can improve the power system reliability, flexibility in economic dispatches, and converter/cable utilizing efficiencies. The dissertation reviews the HVDC technologies, discusses the stability issues regarding the ac and HVDC connections, proposes a novel power oscillation control strategy to improve system stability, and develops a nonlinear voltage droop control strategy for the MTDC grid. To verify the effectiveness the proposed power oscillation control strategy, a long distance paralleled AC-HVDC transmission test system is employed. Based on the PSCAD/EMTDC platform simulation results, the proposed power oscillation control strategy can improve the system dynamic performance and attenuate the power oscillations effectively. To validate the nonlinear voltage droop control strategy, three droop controls schemes are designed according to the proposed nonlinear voltage droop control design procedures. These control schemes are tested in a hybrid AC-MTDC system. The hybrid AC-MTDC system, which is first proposed in this dissertation, consists of two ac grids, two wind farms and a five-terminal HVDC grid connecting them. Simulation studies are performed in the PSCAD/EMTDC platform. According to the simulation results, all the three design schemes have their unique salient

  15. The Applicability of Traditional Protection Methods to Lines Emanating from VSC-HVDC Interconnectors and a Novel Protection Principle

    Directory of Open Access Journals (Sweden)

    Shimin Xue

    2016-05-01

    Full Text Available Voltage source converter (VSC-based high voltage direct current (VSC-HVDC interconnectors can realize accurate and fast control of power transmission among AC networks, and provide emergency power support for AC networks. VSC-HVDC interconnectors bring exclusive fault characteristics to AC networks, thus influencing the performance of traditional protections. Since fault characteristics are related to the control schemes of interconnectors, a fault ride-through (FRT strategy which is applicable to the interconnector operating characteristic of working in four quadrants and capable of eliminating negative-sequence currents under unbalanced fault conditions is proposed first. Then, the additional terms of measured impedances of distance relays caused by fault resistances are derived using a symmetrical component method. Theoretical analysis shows the output currents of interconnectors are controllable after faults, which may cause malfunctions in distance protections installed on lines emanating from interconnectors under the effect of fault resistances. Pilot protection is also inapplicable to lines emanating from interconnectors. Furthermore, a novel pilot protection principle based on the ratio between phase currents and the ratio between negative-sequence currents flowing through both sides is proposed for lines emanating from the interconnectors whose control scheme aims at eliminating negative-sequence currents. The validity of theoretical analysis and the protection principle is verified by PSCAD/EMTDC simulations.

  16. Cooperative control of VSC-HVDC connected offshore wind farm with Low-Voltage Ride-Through capability

    DEFF Research Database (Denmark)

    Liu, Yan; Wang, Xiongfei; Chen, Zhe

    2012-01-01

    The Low-Voltage Ride-Through (LVRT) has become an important grid requirement for offshore wind farms connecting with Voltage Source Converter based High Voltage Direct Current (VSC-HVDC) links. In this paper, a cooperative control strategy with LVRT ability is proposed for a VSC-HVDC connected...... variable speed Squirrel-Cage Induction Generator (SCIG) wind farm. The approach employs a DC-link voltage versus offshore AC-bus frequency droop control on the offshore converter of VSC-HVDC link. Thus, the back-to-back converters of SCIG wind turbines can adjust the generated active power based on the AC......-bus frequency deviations, so that a fast power reduction on the wind farm side can be achieved. The EMTDC/PSCAD simulations are performed on a 300 MW offshore variable speed SCIG wind farm. Simulation results confirm the effectiveness of the proposed control method....

  17. NorthernLights Transmission : bringing competitive cogen energy from the oil sands to west coast markets

    International Nuclear Information System (INIS)

    Hogan, M.J.C.

    2005-01-01

    NorthernLights Transmission is an initiative by TransCanada that proposes 2 major high-voltage direct current (HVDC) transmission lines to bring low cost, fossil fuelled and renewable generation from the Fort McMurray area to growing electricity markets in the Pacific Northwest, Nevada, Arizona and California. This presentation demonstrated why oil sands cogeneration, shipped via NorthernLights Transmission, is a very attractive resource for these markets. It was shown that the best generation resources are tied to natural resources such as coal, wind, oil sands cogeneration and hydro. Both the Pacific Northwest and California markets prefer low carbon dioxide generation. The proposed HVDC transmission lines would maximize the use of existing energy infrastructure corridors and rights-of-way where possible. This paper presented details of the proposed Celilo Project and the Inland Project, and noted that both are attractive from a technical and economic perspective. The transmission line for the Celilo project would originate in Fort McMurray and connect highly efficient cogeneration and other developing forms of generation to growing loads in the Pacific Northwest and northern California. The cogeneration plants will supply steam and electricity to northern Alberta's oil sands developments along with surplus electricity for export. tabs., figs

  18. Economic benefit evaluation for renewable energy transmitted by HVDC based on production simulation (PS) and analytic hierarchy process(AHP)

    Science.gov (United States)

    Zhang, Jinfang; Zheng, Kuan; Liu, Jun; Huang, Xinting

    2018-02-01

    In order to support North and West China’s RE (RE) development and enhance accommodation in reasonable high level, HVDC’s traditional operation curves need some change to follow the output characteristic of RE, which helps to shrink curtailment electricity and curtailment ratio of RE. In this paper, an economic benefit analysis method based on production simulation (PS) and Analytic hierarchy process (AHP) has been proposed. PS is the basic tool to analyze chosen power system operation situation, and AHP method could give a suitable comparison result among many candidate schemes. Based on four different transmission curve combinations, related economic benefit has been evaluated by PS and AHP. The results and related index have shown the efficiency of suggested method, and finally it has been validated that HVDC operation curve in following RE output mode could have benefit in decreasing RE curtailment level and improving economic operation.

  19. Power-hardware-in-the-loop test of VSC-HVDC connection for off-shore wind power plants

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Ranjan [Siemens Wind Power A/S, Brande (Denmark); Technical Univ. of Denmark (Denmark). Center for Electric Technology; Cha, Seung T.; Wu, Qiuwei; Rasmussen, Tonny W.; Oestergaard, Jacob [Technical Univ. of Denmark (Denmark). Center for Electric Technology; Jensen, Kim H. [Siemens Wind Power A/S, Brande (Denmark)

    2011-07-01

    This paper present a power-hardware-in-the-loop (PHIL) test of an off-shore wind power plant (WPP) interconnected to the on-shore grid via a VSC-HVDC connection. The intention of the PHIL test is to verify the hardware interaction and the control co-ordination between the plant side VSC of the HVDC system and the wind turbines within the WPP in order to ensure smooth operation of the WPP under both normal and fault operating condition. The PHIL test platform is comprised of a real time digital simulator (RTDS), a Spitzenberger Spies three phase 7,5 kW power amplifier, a purpose built VSC and a DC chopper. The WPP is simulated in the RTDS as a single full-scale wind turbine. The simulated WPP interacts with the WPP side VSC through the power amplifier. The interface between the RTDS and the power amplifier is done via an analogue GTAO I/O card of the RTDS and the input channel of the amplifier. The amplifier scales up the voltages at the point of connection of the WPP in the RTDS to the voltage level for the WPP side VSC. The WPP side VSC converter is equipped with a DC chopper. The test results show the successful control coordination between the WPP and the plant side VSC converter of the HVDC connection of the WPP. (orig.)

  20. Transients in VSC-HVDC connected offshore wind power plant

    DEFF Research Database (Denmark)

    El-Khatib, Walid Ziad; Schwartzberg, D.; Arana Aristi, I.

    2015-01-01

    The focus of this paper is transient phenomena in VSC-HVDC connected offshore wind power plants (WPPs). With the help of a case study modelled in PSCAD simulation software, energisation events are analysed in the time domain. A comparison with more well-known results obtained at energisation of AC...

  1. Localização de faltas em linhas de transmissão em corrente contínua segmentadas

    Directory of Open Access Journals (Sweden)

    Eduardo Gonzaga Silveira

    2013-11-01

    Full Text Available Este trabalho apresenta uma técnica para a localização de faltas em sistemas de transmissão High Voltage Direct Current (HVDC constituídos por linhas aéreas e cabos isolados. O método foi baseado na coleta de dados de dois terminais nas extremidades do elo de corrente contínua e pela detecção de faltas através de coeficientes da Transformada Wavelet Discreta tipo Haar. A partir do problema proposto, foi simulado com o auxílio do Alternative Transient Program (ATP, um sistema de transmissão em corrente contínua monopolar com conversores a tiristor Current Source Converter (CSC, constituído de duas linhas aéreas de 150 km e 80 km, e um segmento intermediário de cabo subterrâneo com 80 km. Os dados das respostas transitórias de curtos-circuitos em diferentes segmentos do elo foram carregados em uma interface gráfica criada no Matrix Laboratory (MATLAB, para realizar as rotinas de pré-processamento, além de detectar e localizar a falta. O método foi testado para diferentes taxas de amostragem e impedâncias de falta, ele apresentou resultados satisfatórios na localização de faltas em todos os segmentos da linha, com erros em torno de 0,5% do comprimento total do elo, além do baixo custo computacional, o que mostra a viabilidade de sua implementação prática.Palavras-chave: HVDC. Localização de faltas. ATP. Transformada Wavelet.Location of faults in transmission lines in continuous segmented streamAbstractThis paper presents a technique for location of faults in High Voltage Direct Current (HVDC transmission systems constituted of overhead lines and cables. The method was based on data collection of two terminals on the extremity of the continuous stream link, and through the fault detection using the Discrete Wavelet Transform coefficients of Haar type. From the proposed problem, it was simulated, with the support of the Alternative Transient Program (ATP, a transmission system in monopolar continuous stream with

  2. A Novel Modulation Function-Based Control of Modular Multilevel Converters for High Voltage Direct Current Transmission Systems

    Directory of Open Access Journals (Sweden)

    Majid Mehrasa

    2016-10-01

    Full Text Available In this paper, a novel modulation function-based method including analyses of the modulation index and phase is proposed for operation of modular multilevel converters (MMCs in high voltage direct current (HVDC transmission systems. The proposed modulation function-based control technique is developed based on thorough and precise analyses of all MMC voltages and currents in the a-b-c reference frame in which the alternating current (AC-side voltage is the first target to be obtained. Using the AC-side voltage, the combination of the MMC upper and lower arm voltages is achieved as the main structure of the proposed modulation function. The main contribution of this paper is to obtain two very simple new modulation functions to control MMC performance in different operating conditions. The features of the modulation function-based control technique are as follows: (1 this control technique is very simple and can be easily achieved in a-b-c reference frame without the need of using Park transformation; and (2 in addition, the inherent properties of the MMC model are considered in the proposed control technique. Considering these properties leads to constructing a control technique that is robust against MMC parameters changes and also is a very good tracking method for the components of MMC input currents. These features lead to improving the operation of MMC significantly, which can act as a rectifier in the HVDC structure. The simulation studies are conducted through MATLAB/SIMULINK software, and the results obtained verify the effectiveness of the proposed modulation function-based control technique.

  3. Coordinated Voltage Control Scheme for VSC-HVDC Connected Wind Power Plants

    DEFF Research Database (Denmark)

    Guo, Yifei; Gao, Houlei; Wu, Qiuwei

    2017-01-01

    This paper proposes a coordinated voltage control scheme based on model predictive control (MPC) for voltage source converter‐based high voltage direct current (VSC‐HVDC) connected wind power plants (WPPs). In the proposed scheme, voltage regulation capabilities of VSC and WTGs are fully utilized...... and optimally coordinated. Two control modes, namely operation optimization mode and corrective mode, are designed to coordinate voltage control and economic operation of the system. In the first mode, the control objective includes the bus voltages, power losses and dynamic Var reserves of wind turbine...

  4. hvdc simulation aids system planner

    Energy Technology Data Exchange (ETDEWEB)

    Ottevangers, J H

    1966-06-01

    The first commercial dc transmission line, powered by mercury-arc converters, was installed 12 years ago. The transmission capacity of the line was limited to 20 MW. In 1965, three dc links were commissioned, the largest suitable for 600 MW, and a line with a capacity of 1,440 MW is now in the design stage. Operating experience on the existing projects has demonstrated the reliability of dc transmission and, even though widespread use of dc is not expected immediately because of the relative high cost of terminal equipment, it is worthwhile considering the possible application of dc when planning network expansions.

  5. Advanced fault ride-through control of DFIG based wind turbines including grid connection via VSC-HVDC

    Energy Technology Data Exchange (ETDEWEB)

    Feltes, Christian

    2012-07-01

    With the growing renewable energy share in the power generation mix it becomes inevitable that also these new generation technologies participate on the provision of grid services to guarantee stable operation of the grid, especially when one considers the decreasing number of conventional power plants in operation as a result of the expansion of wind based generation plants. These so-called ancillary services include frequency / active power control, voltage / reactive power control and fault ride-through (FRT) with fast voltage control and are stipulated in modern grid codes. In the context of this thesis advanced control algorithms have been developed for wind turbines based on doubly-fed induction generator (DFIG) to allow safe FRT during symmetrical and unsymmetrical faults. This covers the control for conventional AC grid connection as well as for the connection through voltage source converter (VSC) based high voltage direct current transmission (HVDC). Currently, the DFIG is the most used generator technology in modem wind turbines, since it combines a relatively simple slip-ring induction machine with a frequency converter rated to only approx. 30% of the total power. This makes the DFIG a cost-effective concept, which offers a variable speed range and a high degree of flexibility in control. However, due to the direct coupling of the generator stator circuit to the grid, grid faults are a special challenge for the frequency converter, its protection circuits and control algorithms. As base for the detailed evaluation of the impact of grid faults to the DFIG, this thesis contains the analytical derivation of the DFIG short circuit currents under consideration of frequency converter control. The DFIG concept presented in this thesis makes use of a DC chopper in the frequency converter, which allows safe FRT with grid voltage support through both converter sides. The developed control contains a new algorithm for a clear separation and control of positive

  6. Fulfilment of Grid Code Obligations by Large Offshore Wind Farms Clusters Connected via HVDC Corridors

    OpenAIRE

    Attya, A.B.; Anaya-Lara, Olimpo; Ledesma, P.; Svendsen, Harald Georg

    2016-01-01

    - The foreseen high penetration levels of wind power will force the systems operators to apply restrictive constraints on wind power plants. The ability of offshore wind clusters, which are connected via HVDC, to fulfill the grid codes, especially those related to voltage stability is investigated. This came in the frame of a project to develop an integrated and practical tool to design offshore wind clusters (EERA-DTOC). The applied case studies examine the system stability during and aft...

  7. Frequency Support from OWPPs connected to HVDC via Diode Rectifiers

    DEFF Research Database (Denmark)

    Saborío-Romano, Oscar; Bidadfar, Ali; Göksu, Ömer

    This paper presents a study assessing the actual capability of an offshore wind power plant (offshore WPP, OWPP) to provide frequency support (FS) to an onshore network, when connected through a high-voltage direct-current (HVDC) link having a diode rectifier (DR) offshore terminal and a voltage...

  8. A New Coordinated Voltage Control Scheme for Offshore AC Grid of HVDC Connected Offshore Wind Power Plants

    DEFF Research Database (Denmark)

    Sakamuri, Jayachandra N.; Cutululis, Nicolaos Antonio; Rather, Zakir Hussain

    2015-01-01

    This paper proposes a coordinated voltage control scheme (CVCS) which enhances the voltage ride through (VRT) capability of an offshore AC grid comprised of a cluster of offshore wind power plants (WPP) connected through AC cables to the offshore voltage source converter based high voltage DC (VSC......-HVDC) converter station. Due to limited short circuit power contribution from power electronic interfaced variable speed wind generators and with the onshore main grid decoupled by the HVDC link, the offshore AC grid becomes more vulnerable to dynamic voltage events. Therefore, a short circuit fault...... in the offshore AC Grid is likely to have significant implications on the voltage of the offshore AC grid, hence on the power flow to the onshore mainland grid. The proposed CVCS integrates individual local reactive power control of wind turbines and of the HVDC converter with the secondary voltage controller...

  9. Computationally Efficient Transient Stability Modeling of multi-terminal VSC-HVDC

    DEFF Research Database (Denmark)

    van der Meer, Arjen A; Rueda-Torres, José; Silva, Filipe Miguel Faria da

    2016-01-01

    This paper studies the inclusion of averaged VSC-based grid interfaces and HVDC networks into stability type simulations, and compares the accuracy and speed of three multi-terminal DC dynamic models: 1) a state-space based model, 2) a multi-rate improved model, and 3) a reduced-order model...

  10. Lifetime Estimation of MMC for Offshore Wind Power HVDC Application

    DEFF Research Database (Denmark)

    Liu, Hui; Ma, Ke; Loh, Poh Chiang

    2014-01-01

    of these could lead to thermo-mechanical fatigues in the components and joints of the power modules and thereby causing reliability challenge. This study focuses on the lifetime evaluation of MMC based on power cycling and thermal cycling considering the mission profiles in the High Voltage Direct Current (HVDC...

  11. Lifetime Estimation of MMC for Offshore Wind Power HVDC Application

    DEFF Research Database (Denmark)

    Liu, Hui; Ma, Ke; Qin, Zian

    2016-01-01

    of these could lead to thermomechanical fatigues in the components and joints of the power modules and thereby causing reliability challenge. This study focuses on the lifetime evaluation of MMC based on power cycling and thermal cycling considering the mission profiles in the High Voltage Direct Current (HVDC...

  12. Flexible AC transmission systems. Modelling and control

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xiao-Ping [Birmingham Univ. (United Kingdom); Rehtanz, Christian [Technische Univ. Dortmund (Germany); Pal, Bikash [Imperial College, London (United Kingdom)

    2012-11-01

    This monograph presents advanced modelling, analysis and control techniques of FACTS. These topics reflect the recent research and development of FACTS controllers, and anticipate the future applications of FACTS in power systems. The book covers comprehensively a range of power-system control problems: from steady-state voltage and power flow control, to voltage and reactive power control, to voltage stability control, to small signal stability control using FACTS controllers. The book presents the modelling of the latest FACTS controllers for power flow control, compensation and power quality (IPFC, GUPF, VSC HVDC and M-VSCHVDC, etc.) in power system analysis. The selection is evaluated by the actual and likely future practical relevance of each. The material is derived mainly from the research and industrial development in which the authors have been heavily involved. The book is timely and of great value to power engineering engineers and students of modelling, simulations and control design of FACTS for a broad practical range of power system operation, planning and control problems.

  13. Recent and future situation of Japan’s T&D system

    Directory of Open Access Journals (Sweden)

    Kyoichi Uehara

    2016-01-01

    Full Text Available Japan suffered from the Great East Japan Earthquake followed by the nuclear disaster. As a result, we experienced rolling outages for a few months in the Tokyo and Tohoku area. Japan’s power transmission system consists of 50 Hz AC and 60 Hz AC in eastern and western Japan respectively. When the nuclear disaster occurred in Fukushima, enough electricity hasn’t been supplied in eastern area. Power interchange capacity between east and west was small because of small redundant T&D system design. Based on this rolling outage and some present electricity supplying issues in Japan, METI (Ministry of Economy, Trade and Industry has set the electricity system reform committee to improve this situation and make a good T&D system for the future. This committee reported the discussed issue to the Japanese METI and METI proposed policy on Electricity System Reform to the Japanese Cabinet. As a result, the Japanese Electricity System Reform policy was adopted. This future T&D system deals with redundant T&D systems between east and west, how to handle large amounts of renewable electrical energy, and how to fully de-regulate the distribution market. HVDC (VSC system will be introduced between Hokkaido and Honshu as a subsea cable transmission system and HVDC transmission system between eastern area and western area. This paper describes recent and future Japan’s T&D systems. This will be helpful to understand how to solve the issues of Japan’s T&D system.

  14. A comparison of the technological, economic, public policy, and environmental factors of HVDC and HVAC interregional transmission

    Directory of Open Access Journals (Sweden)

    Armando L. Figueroa-Acevedo

    2015-02-01

    Full Text Available The design of an interregional high-voltage transmission system in the US is a revolutionary technological concept that will likely play a significant role in the planning and operation of future electric power systems. Historically, the primary justification for building interregional high-voltage transmission lines in the US and around the world has been based on economic and reliability criteria. Today, the implementation renewable portfolio standards, carbon emission regulations, the improvements in the performance of power electronic systems, and unused benefits associated with capacity exchange during times of non-coincident peak demand, are driving the idea of designing an interregional high-voltage transmission system in the US. However, there exist challenges related to technical, economic, public policy, and environmental factors that hinder the implementation of such a complex infrastructure. The natural skepticism from many sectors of the society, in regards to how will the system be operated, how much will it cost, and the environmental impact that it could potentially create are among the most significant challenges to its rapid implementation. This publication aims at illustrating the technological, environmental, economic, and policy challenges that interregional HV transmission systems face today in the US, looking specifically at the Clean Line Rock Island project in Iowa.

  15. New technology for improved utilization of the interconnected power system; Ny teknologi for bedre utnyttelse av overfoerings-systemet

    Energy Technology Data Exchange (ETDEWEB)

    Enger, A.K.

    1996-12-31

    The present paper deals with methods used for improving the utilization of interconnected power systems. The author discusses new technologies for improvement and safety of power transmission. Main themes covered in this paper are HVDC (High Voltage DC) systems in Norway, possibilities of load management control, other possible/necessary measures in the grid system, and the development and trends. 21 figs.

  16. Charging large capacitor banks for fusion research using HVDC conversion equipment

    International Nuclear Information System (INIS)

    Brown, D.R.; Bird, W.L.; Huang, Y.C.; Tolk, K.

    1984-01-01

    Fundamental considerations in the choice of a continuous duty capacitor bank charging system using HVDC conversion equipment are presented. Large systems of the type used in fusion related research pose significant system related problems if they are to be supplied from a conventional power grid. Schemes for conditioning the required power in order to overcome such problems are presented and evaluated. A resonant charging system is examined in detail and shown to be superior in a number of ways to constant current charging. Results of digital computer simulation studies are used to demonstrate the feasibility of the system. It is shown that the resonant charging system reduces rectifier capacity, simplifies control and reduces reactive power fluctuations. Sequential bank charging and use of a motor-generator set are presented as techniques for compensation of real power fluctuations and a comparison on the basis of initial cost is presented

  17. A novel concept of fault current limiter based on saturable core in high voltage DC transmission system

    Science.gov (United States)

    Yuan, Jiaxin; Zhou, Hang; Gan, Pengcheng; Zhong, Yongheng; Gao, Yanhui; Muramatsu, Kazuhiro; Du, Zhiye; Chen, Baichao

    2018-05-01

    To develop mechanical circuit breaker in high voltage direct current (HVDC) system, a fault current limiter is required. Traditional method to limit DC fault current is to use superconducting technology or power electronic devices, which is quite difficult to be brought to practical use under high voltage circumstances. In this paper, a novel concept of high voltage DC transmission system fault current limiter (DCSFCL) based on saturable core was proposed. In the DCSFCL, the permanent magnets (PM) are added on both up and down side of the core to generate reverse magnetic flux that offset the magnetic flux generated by DC current and make the DC winding present a variable inductance to the DC system. In normal state, DCSFCL works as a smoothing reactor and its inductance is within the scope of the design requirements. When a fault occurs, the inductance of DCSFCL rises immediately and limits the steepness of the fault current. Magnetic field simulations were carried out, showing that compared with conventional smoothing reactor, DCSFCL can decrease the high steepness of DC fault current by 17% in less than 10ms, which verifies the feasibility and effectiveness of this method.

  18. Rats avoid exposure to HVdc electric fields: a dose response study.

    Science.gov (United States)

    Creim, J A; Lovely, R H; Weigel, R J; Forsythe, W C; Anderson, L E

    1993-01-01

    Rats, given the choice, avoid exposure to alternating current (ac) 60-Hz electric fields at intensities > or = 75 kV/m. This study investigated the generality of this behavior by studying the response of rats when exposed to high voltage direct current (HVdc) electric fields. Three hundred eighty male Long Evans rats were studied in 9 experiments with 40 rats per experiment and in one experiment with 20 rats to determine 1) if rats avoid exposure to HVdc electric fields of varying field strengths, and 2) if avoidance did occur, what role, if any, the concentration of air ions would have on the avoidance behavior. In all experiments a three-compartment glass shuttlebox was used; either the left or right compartment could be exposed to a combination of HVdc electric fields and air ions while the other compartment remained sham-exposed. The third, center compartment was a transition zone between exposure and sham-exposure. In each experiment, the rats were individually assessed in 1-h sessions where half of the rats (n = 20) had the choice to locomote between the two sides being exposed or sham-exposed, while the other half of the rats (n = 20) were sham-exposed regardless of their location, except in one experiment where there was no sham-exposed group. The exposure levels for the first six experiments were 80, 55, 42.5, 30, -36, and -55 kV/m, respectively. The air ion concentration was constant at 1.4 x 10(6) ions/cc for the four positive exposure levels and -1.4 x 10(6) ions/cc for the two negative exposure levels. Rats having a choice between exposure and non-exposure relative to always sham-exposed control animals significantly reduced the amount of time spent on the exposed side at 80 kV/m (P HVdc exposure level was held constant at either -55 kV/m (for three experiments) or -55 kV/m (for 1 experiment) while the air ion concentration was varied between experiments at 2.5 x 10(5) ions/cc, 1.0 x 10(4) for two of the experiments and was below the measurement limit

  19. 9{sup th} international workshop on large-scale integration of wind power into power systems as well as on transmission networks for offshore wind power plants. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Betancourt, Uta; Ackermann, Thomas (eds.)

    2010-07-01

    Within the 9th International Workshop on large-scale integration of wind power into power systems as well as on transmission networks for offshore wind power plants at 18th to 19th October, 2010 in Quebec (Canada), lectures and poster papers were presented to the following themes: (1) Keynote session and panel; (2) European grid integration studies; (3) Modeling; (4) Wind forecasting; (5) North American grid integration studies; (6) Voltage stability and control; (7) Grid codes and impact studies; (8) Canadian University research (WESNet); (9) Operation and dispatch; (9) Offshore wind power plants; (10) Frequency Control; (11) Methodologies to estimate wind power impacts on power systems, summaries from IEAWIND collaboration; (12) HVDC; (13) Grid codes and system impact studies; (14) Modeling and validation; (15) Regulations, markets and offshore wind energy; (16) Integration issues; (17) Wind turbine control system; (18) Energy management and IT solutions.

  20. Approches pour la reduction de l'impact de defaut dans le transport d'energie du parc eolien offshore via VSC-HVDC =

    Science.gov (United States)

    Benadja, Mounir

    tenant compte des entrees de chacune des stations. L'integration des observateurs non-lineaires (EKF) dans le controle des convertisseurs permet de resoudre le probleme des incertitudes de mesure, des incertitudes dans la modelisation, en cas du dysfonctionnement ou de panne des capteurs de mesure ainsi que le probleme de l'impact des defauts (AC et DC) sur la qualite d'energie dans les systemes de transmission. Ces estimations contribuent a rendre le cout global du systeme moins cher et sa taille moins encombrante ainsi que la reduction de l'impact des defauts (AC et DC) sur le systeme. La troisieme contribution concerne la reduction de la taille, du cout et de l'impact des defauts electriques (AC et DC) dans le systeme construit pour transporter l'energie d'un parc eolien offshore (OWF) vers le reseau principal AC onshore via deux stations VSC-HVDC. La solution developpee utilise des observateurs non-lineaires bases sur le filtre de Kalman etendu (EKF). Ce filtre permet d'estimer la vitesse de rotation et la position du rotor de chacune des generatrices du parc eolien et de la tension du bus DC de l'onduleur DC-AC offshore. La contribution porte surtout sur le developpement des deux commandes des deux stations. La premiere, la commande non-lineaire modifiee pour controler le premier convertisseur de la station VSC-HVDC offshore assurant le transfert de la puissance generee par le parc eolien vers la station VSC-HVDC onshore. La deuxieme commande non-lineaire modifiee avec integration de la regulation de la tension du bus DC et de la commande a modele de reference adaptative (MRAC) pour la compensation des surintensites et surtensions durant les defauts AC et DC. On peut constater que lors d'un defaut AC au PCC (Point of Common Coupling) du cote reseau onshore, la profondeur de l'impact du defaut AC sur l'amplitude des courants du reseau principal AC onshore qui etait reduit a 60% par les travaux de recherche (Erlich, Feltes et Shewarega, 2014), comparativement a la

  1. Linealización de sistemas VSC-HVDC para el diseño de un controlador PI vectorial

    Directory of Open Access Journals (Sweden)

    Nelson Díaz Aldana

    2014-01-01

    Full Text Available Los sistemas VSC-HVDC son muy utilizados para la transmisión de energía en redes de interconexión eléctrica. Uno de los principales problemas que poseen estos sistemas es la complejidad de su modelo matemático, lo que conlleva grandes dificultades para el diseño de controladores que permitan la regulación de parámetros como la tensión DC de transmisión, así como la potencia activa y reactiva del sistema VSC-HVDC. En este artículo se presenta la linealización de un sistema VSC-HVDC y el posterior diseño de un controlador lineal PI vectorial a partir del modelo linealizado. Adicionalmente, se proponen dos estrategias para la validación de este tipo de controladores, la primera consiste en un único controlador PI para regular los estados del sistema para cada VSC, la segunda consiste en el diseño de controladores PI vectoriales independientes para la regulación de cada estado del VSC.

  2. The judgement of simultaneous commutation failure in HVDC about hierarchical connection to AC grid

    Science.gov (United States)

    Li, Ming; Song, Xinli; Huang, Daoshan; Liu, Wenzhuo; Zhao, Shutao; Ye, Xiaohui; Meng, Hang

    2017-09-01

    The hierarchical connection to AC grid at inverter sides in UHVDC has been take in several projects. This paper introduced the frame of the connection mode in hierarchical access system and compared it with the traditional one at the case of HVDC-Cigre. Then the criterion of commutation failure according to the same valves current was deduced. In order to verify the accuracy of the criterion, this paper used PSD-BPA (Bonneville Power Administration) to simulate the setting voltage drop in the East China power grid and certified the correctness of the formula.

  3. 8th international workshop on large-scale integration of wind power into power systems as well as on transmission networks for offshore wind farms. Proceedings

    International Nuclear Information System (INIS)

    Betancourt, Uta; Ackermann, Thomas

    2009-01-01

    Within the 8th International Workshop on Large-Scale Integration of Wind Power into Power Systems as well as on Transmission Networks for Offshore Wind Farms at 14th to 15th October, 2009 in Bremen (Federal Republic of Germany), lectures and posters were presented to the following sessions: (1) Keynote session and panel; (2) Grid integration studies and experience: Europe; (3) Connection of offshore wind farms; (4) Wind forecast; (5) High voltage direct current (HVDC); (6) German grid code issues; (7) Offshore grid connection; (8) Grid integration studies and experience: North America; (9) SUPWIND - Decision support tools for large scale integration of wind; (10) Windgrid - Wind on the grid: An integrated approach; (11) IEA Task 25; (12) Grid code issues; (13) Market Issues; (14) Offshore Grid; (15) Modelling; (16) Wind power and storage; (17) Power system balancing; (18) Wind turbine performance; (19) Modelling and offshore transformer.

  4. The Development and Demonstration of a 360m/10 kA HTS DC Power Cable

    Science.gov (United States)

    Xiao, Liye

    With the quick development of renewable energy, it is expected that the electric power from renewable energy would be the dominant one for the future power grid. Due to the specialty of the renewable energy, the HVDC power transmission would be very useful for the transmission of electric power from renewable energy. DC power cable made of High Tc Superconductor (HTS) would be a possible alternative for the construction of HVDC power transmission system. In this chapter, we report the development and demonstration of a 360 m/10 kA HTS DC power cable and the test results.

  5. Offshore wind power plants with VSC-HVDC transmission : Grid code compliance optimization and the effect on high voltage ac transmission system

    NARCIS (Netherlands)

    Ndreko, M.

    2017-01-01

    The development of large offshore wind power generation in the North Sea has been significantly accelerated in the last years. The large distance from shore in combination with the need for large transmission capacity has raised the interest for the voltage source converter high voltage direct

  6. Proceedings of the 2009 CIGRE Canada conference on power systems : innovation and renewal : building the new power system

    International Nuclear Information System (INIS)

    2009-01-01

    The Conseil International des Grands Reseaux Electriques (CIGRE) is the International Council on Large Electric Systems. It promotes technical, economic and environmental developments in electricity transmission and generation. CIGRE Canada is the Canadian National Committee which fosters the participation of Canadian members in CIGRE activities. CIGRE Canada organizes an annual conference that provides a forum for power system engineers, decision makers,economists, and academics to discuss technological developments in electrical power systems. The presentations at this conference addressed issues regarding the use of renewable energy sources in power transmission and distribution systems, with particular reference to control and protection; HVDC and MVDC; modelling tools; interface technologies; and reduced carbon generation and sustainability. The use of active distribution systems was also discussed in terms of future trends; the role of information technology and communications; and the role of energy storage. The session on smart grids addressed issues such as power utility perspectives; sensing, measurements and controls; advanced interfaces and decision support systems; open-architecture; distributed energy resources; and regulatory issues. Issues concerning the interconnection of non traditional energy sources to the power systems were also discussed along with recent research initiatives related to renewable energy source development. The sessions were entitled: smart grids; distributed energy resources; wind and solar PV; AC systems and HV lines; wide area measurements; power system operation and control; modelling and analysis; substation automation; and HVDC and facts. The conference featured 66 presentations, of which 35 have been catalogued separately for inclusion in this database

  7. Connection of OWPPs to HVDC networks using VSCs and Diode Rectifiers: an Overview

    DEFF Research Database (Denmark)

    Saborío-Romano, Oscar; Bidadfar, Ali; Göksu, Ömer

    This paper provides an overview of two technologies for connecting offshore wind power plants (offshore WPPs, OWPPs) to high-voltage direct current (HVDC) networks: voltage source converters (VSCs) and diode rectifiers (DRs). Current grid code requirements for the connection of such power plants...

  8. Transmission and Distribution: AREVA takes further action to reinforce its presence in China

    International Nuclear Information System (INIS)

    2007-05-01

    Following the recent opening of its new gas-insulated switchgear factory last month in Suzhou, China, AREVA's Transmission and Distribution (T and D) division has announced additional actions to increase its market share in the country. The division has just signed an agreement to form a 50/50 joint venture with the Chinese company, Sunten Electric Co. Ltd., a leading manufacturer of distribution transformers, whose 2006 annual sales reached circa euro 120 million. Through this joint venture, AREVA T and D will become No 1 in China for dry-type transformers, Sunten Electric Co. Ltd.'s specialization. AREVA T and D has also established a partnership with the China Electric Power Research Institute (C-EPRI), a leading Chinese organization specialized in electrical technologies. Under the agreement, C-EPRI will be the official licensee for AREVA T and D's H-400 high-voltage direct current (HVDC) Thyristor valves in China. The partnership will enable AREVA T and D to enter the fast-growing domestic HVDC market. The T and D sector in China represents 24% of the worldwide transmission and distribution market. AREVA T and D's turnover in China, where demand for T and D equipment is growing strongly, should significantly contribute to the division's objective to reach euro 5 billion in sales by 2010

  9. InfiniBand-based real-time simulation of HVDC, STATCOM and SVC devices with commercial-off-the-shelf PCs and FPGAs

    Energy Technology Data Exchange (ETDEWEB)

    Dufour, C.; Abourida, S.; Belanger, J.; Lapointe, V. [OPAL-RT Technologies Inc., Montreal, PQ (Canada)

    2006-07-01

    Details of a real-time simulator for large power networks using commercial-off-the-shelf products and an RT-LAB platform were presented. The simulator was designed to realistically simulate bipolar high voltage DC (HVDC) networks transmission systems and to meet large grid simulation challenges. The system was also designed to cope with complex power grid design and validation tests as well as to interface with modern power electronic controllers and protection systems. The platform used Pentium, Xeon or Opteron based PCs and InfiniBand communication fabric for fast inter-PC communications. The real-time PC ran under well-known operating systems while the main control interface used Simulink software. Grid circuits were designed using an SPS interface using an ARTEMIS plug-in. Various model performances were reported. The results of several simulations suggested that InfiniBand communication was slower than shared-memory communication, while STATCOM timing was difficult to compare with the Opteron benchmarks. Results also suggested that XEON CPUs were slower than Opteron counterparts. Hardware-in-the-loop (HIL) testing was also performed with a prototype controller and with a real production controller. It was concluded that a communication time of 5 microseconds was obtained across the 2 PCs. The paper also discussed recent advances in HIL simulation and programming devices. 10 refs., 15 figs.

  10. Heat control in HVDC resistive divider by PID and NN controllers

    International Nuclear Information System (INIS)

    Yilmaz, S.; Dincer, H.; Eksin, I.; Kalenderli, O.

    2007-01-01

    In this study, a control system is presented that is devised to increase measurement precisions within a prototype high voltage DC resistive divider (HVDC-RD). Since one of the major sources of measurement errors in such devices is the self heating effect, a system controlling the temperature within the high voltage DC resistive divider is devised so that suitable and stable temperature conditions are maintained that, in return, will decrease the measurement errors. The resistive divider system is cooled by oil, and PID and neural network (NN) controllers try to keep the temperature within the prescribed limits. The system to be controlled exhibits a nonlinear character, and therefore, a control approach based on NN controllers is proposed. Thus, a system that can fulfill the various requirements dictated by the designer is constructed. The performance of the NN controller is compared with that of the PID controller developed for the same purpose, and the values of the performance indices indicate the superiority of the NN controller over that of the classical PID controller

  11. Control and Protection of Wind Power Plants with VSC-HVDC Connection

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay

    oscillations, and hence, lower dc voltage overshoots in the VSC-HVDC system. On the protection side, the coordination of over-current relays has been analysed in the new environment. A simple yet reliable scheme utilizing the well-known over-current relay characteristics has been presented for the detection...... grid frequency from the onshore grid frequency. Three different methods have been evaluated here for relaying the onshore grid frequency to the offshore grid, such that the wind power plant can participate in the grid frequency control. One of the schemes does not involve communication, while the other...... of faults and the determination of faulted feeder in the offshore grid. It is demonstrated that the communication capability of modern relays can help avoid the potential cases of over-reach. The test system is modelled for real time simulation in RSCAD/RTDS platform, such that the physical relays could...

  12. Physical processes in high field insulating liquid conduction

    Science.gov (United States)

    Mazarakis, Michael; Kiefer, Mark; Leckbee, Joshua; Anderson, Delmar; Wilkins, Frank; Obregon, Robert

    2017-10-01

    In the power grid transmission where a large amount of energy is transmitted to long distances, High Voltage DC (HVDC) transmission of up to 1MV becomes more attractive since is more efficient than the counterpart AC. However, two of the most difficult problems to solve are the cable connections to the high voltage power sources and their insulation from the ground. The insulating systems are usually composed of transformer oil and solid insulators. The oil behavior under HVDC is similar to that of a weak electrolyte. Its behavior under HVDC is dominated more by conductivity than dielectric constant. Space charge effects in the oil bulk near high voltage electrodes and impeded plastic insulators affect the voltage oil hold-off. We have constructed an experimental facility where we study the oil and plastic insulator behavior in an actual HVDC System. Experimental results will be presented and compared with the present understanding of the physics governing the oil behavior under very high electrical stresses. Sandia National Laboratories managed and operated by National Technology and Engineering Solutions of Sandia, LLC., a wholly owned subsidiary of Honeywell International, Inc., for the U.S. D.O.E., NNSA under contract DE-NA-0003525.

  13. On the use of programmable logical controllers (PLC) in the emergency control schemes for the 750 kV system

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Roberto Campos de; Oliveira, Mario Cesar Santos de [FURNAS, Rio de Janeiro, RJ (Brazil)

    1994-12-31

    The energy produced at the Itaipu Power Plant for the Brazilian Interconnected System is transmitted through two different transmission system: -HVDC system, with two bipoles of +- 600 kV, 6300 MW which connect the substation of Foz do Iguacu in the State of Parana, to substation of Ibiuna in the State of Sao Paulo, transmitting the energy generated in 50 Hz units. This system was entirely commissioned on september of 1987. (author) 3 refs., 5 figs.

  14. Modelling of HVDC wall bushing flashover in nonuniform rain

    International Nuclear Information System (INIS)

    Rizk, F.A.M.; Kamel, S.I.

    1991-01-01

    This paper presents the first mathematical model to provide necessary and sufficient conditions for flashover of an HVDC wall bushing under nonuniform rain. The suggested mechanism is initiated by streamer bridging of the dry zone enhanced by nonuniform voltage distribution along the bushing and within the dry zone. Fast voltage collapse across the dry zone die to energy stored in the bushing stray capacitance to ground leads to impulsive stressing of the wet part of the bushing. The nonuniform distribution of the impulse stress and the process of streamer bridging, fast voltage collapse as well as subsequent recharging of the bushing capacitances can lead to continued discharge propagation and flashover of the complete bushing. The findings of the model have been satisfactorily compared with previous experiments and field observations and can, for the first time, account for the following aspects of the flashover mechanism: critical dry zone length, polarity effect, specific leakage path, wet layer conductance per unit leakage length as well as the DC system voltage

  15. Heat dissipation computations of a HVDC ground electrode using a supercomputer

    International Nuclear Information System (INIS)

    Greiss, H.; Mukhedkar, D.; Lagace, P.J.

    1990-01-01

    This paper reports on the temperature, of soil surrounding a High Voltage Direct Current (HVDC) toroidal ground electrode of practical dimensions, in both homogeneous and non-homogeneous soils that was computed at incremental points in time using finite difference methods on a supercomputer. Curves of the response were computed and plotted at several locations within the soil in the vicinity of the ground electrode for various values of the soil parameters

  16. Transmission market support system

    International Nuclear Information System (INIS)

    Reinschmidt, K.F.; Coles, B.C.

    1995-01-01

    An interactive, computer-based market support system has been developed for transmission access that is efficient, equitable, and fair to all parties concerned with electrical transmission: utilities, electric generators, owners of transmission networks, and wholesale purchasers of electrical power. Each participant transmits electronically to the computer system his proposed price schedule for buying, selling, or transmitting power for each future time period. The price for transmission on a single line in one direction can differ from the price in the other direction. The total quantity offered in the transmission bid represents the capacity of the line, and the flow on the line cannot exceed this value. The system automatically computes the prices that clear the market; that is, the price that each generator receives at each bus, the price that each transmission operator receives on each line, and the price that each customer pays at each bus. The computer system maximizes the benefits to all three classes while satisfying the electrical characteristics of the transmission system by means of load flow calculations. Customers never pay more than their bid prices (but may pay less), and generators and transmission operators never receive less than their bid prices (but may receive more). The price at each bus applies to all buyers and sellers at that bus: all buyers at the same bus pay the same price and all generators at a bus receive the same price

  17. A Transient Fault Recognition Method for an AC-DC Hybrid Transmission System Based on MMC Information Fusion

    Directory of Open Access Journals (Sweden)

    Jikai Chen

    2016-12-01

    Full Text Available At present, the research is still in the primary stage in the process of fault disturbance energy transfer in the multilevel modular converter based high voltage direct current (HVDC-MMC. An urgent problem is how to extract and analyze the fault features hidden in MMC electrical information in further studies on the HVDC system. Aiming at the above, this article analyzes the influence of AC transient disturbance on electrical signals of MMC. At the same time, it is found that the energy distribution of electrical signals in MMC is different for different arms in the same frequency bands after the discrete wavelet packet transformation (DWPT. Renyi wavelet packet energy entropy (RWPEE and Renyi wavelet packet time entropy (RWPTE are proposed and applied to AC transient fault feature extraction from electrical signals in MMC. Using the feature extraction results of Renyi wavelet packet entropy (RWPE, a novel recognition method is put forward to recognize AC transient faults using the information fusion technology. Theoretical analysis and experimental results show that the proposed method is available to recognize transient AC faults.

  18. Use of a graphical user interface approach for digital and physical simulation in power systems control education

    International Nuclear Information System (INIS)

    Shoults, R.R.; Barrera-Cardiel, E.

    1992-01-01

    This paper presents the design of a laboratory with software and hardware structures for digital and physical simulation in the area of Power Systems Control Education. The hardware structure includes a special man-machine interface designed with a graphical user interface approach. This interface allows the user full control over the simulation and provides facilities for the study of the response of the simulated system. This approach is illustrated with the design of a control system for a physically based HVDC transmission system model

  19. Transient Stability Assessment of Power System with Large Amount of Wind Power Penetration

    DEFF Research Database (Denmark)

    Liu, Leo; Chen, Zhe; Bak, Claus Leth

    2012-01-01

    Recently, the security and stability of power system with large amount of wind power are the concerned issues, especially the transient stability. In Denmark, the onshore and offshore wind farms are connected to distribution system and transmission system respectively. The control and protection...... methodologies of onshore and offshore wind farms definitely affect the transient stability of power system. In this paper, the onshore and offshore wind farms are modeled in detail in order to assess the transient stability of western Danish power system. Further, the computation of critical clearing time (CCT...... plants, load consumption level and high voltage direct current (HVDC) transmission links are taken into account. The results presented in this paper are able to provide an early awareness of power system security condition of the western Danish power system....

  20. Mid-Atlantic Offshore Wind Interconnection and Transmission (MAOWIT)

    Energy Technology Data Exchange (ETDEWEB)

    Kempton, Willett [Univ. of Delaware, Newark, DE (United States)

    2016-04-05

    This project has carried out a detailed analysis to evaluate the pros and cons of offshore transmission, a possible method to decrease balance-of-system costs and permitting time identified in the DOE Office Wind Strategic Plan (DOE, 2011). It also addresses questions regarding the adequacy of existing transmission infrastructure and the ability of existing generating resources to provide the necessary Ancillary Services (A/S) support (spinning and contingency reserves) in the ISO territory. This project has completed the tasks identified in the proposal: 1. Evaluation of the offshore wind resource off PJM, then examination of offshore wind penetrations consistent with U.S. Department of Energy’s (DOE) targets and with their assumed resource size (DOE, 2011). 2. Comparison of piecemeal radial connections to the Independent System Operator (ISO) with connections via a high-voltage direct current (HVDC) offshore network similar to a team partner. 3. High-resolution examination of power fluctuations at each node due to wind energy variability 4. Analysis of wind power production profiles over the Eastern offshore region of the regional ISO to assess the effectiveness of long-distance, North- South transmission for leveling offshore wind energy output 5. Analysis of how the third and fourth items affect the need for ISO grid upgrades, congestion management, and demand for Ancillary Services (A/S) 6. Analysis of actual historic 36-hr and 24-hr forecasts to solve the unit commitment problem and determine the optimal mix of generators given the need to respond to both wind variability and wind forecasting uncertainties.

  1. Wireless data signal transmission system

    DEFF Research Database (Denmark)

    2014-01-01

    The present invention relates to a method for providing a radio frequency signal for transmission, a system for providing a radio frequency signal for transmission and a method for wireless data transmission between a transmitter and a receiver.......The present invention relates to a method for providing a radio frequency signal for transmission, a system for providing a radio frequency signal for transmission and a method for wireless data transmission between a transmitter and a receiver....

  2. Field distribution on an HVDC wall bushing during laboratory rain tests

    International Nuclear Information System (INIS)

    Lampe, W.; Wikstrom, D.; Jacobson, B.

    1991-01-01

    This paper reports that an efficient counter-measure to suppress flashovers across HVDC wall bushings is to make their surfaces hydrophobic. This laboratory investigation reports the measured electric field along such a bushing under different environmental conditions. A significantly reduced radial field strength has been found for the hydrophobic bushing. Moreover, the total field strength distribution becomes almost independent of the prevailing dry zone. The flashover voltage for bushings with a hydrophobic surface is therefore significantly increased

  3. Power-flow control and stability enhancement of four parallel-operated offshore wind farms using a line-commutated HVDC link

    DEFF Research Database (Denmark)

    Wang, Li; Wang, Kuo-Hua; Lee, Wei-Jen

    2010-01-01

    This paper presents an effective control scheme using a line-commutated high-voltage direct-current (HVDC) link with a designed rectifier current regulator (RCR) to simultaneously perform both power-fluctuation mitigation and damping improvement of four parallel-operated 80-MW offshore wind farms...... delivering generated power to a large utility grid. The proposed RCR of the HVDC link is designed by using modal control theory to contribute adequate damping to the studied four offshore wind farms under various wind speeds. A systematic analysis using a frequency-domain approach based on eigenvalue...... characteristics to the studied offshore wind farms under various wind speeds but also effectively mitigate power fluctuations of the offshore wind farms under wind-speed disturbance conditions....

  4. High frequent modelling of a modular multilevel converter using passive components

    DEFF Research Database (Denmark)

    El-Khatib, Walid Ziad; Holbøll, Joachim; Rasmussen, Tonny Wederberg

    2013-01-01

    ). This means that a high frequency model of the converter has to be designed, which gives a better overview of the impact of high frequency transients etc. The functionality of the model is demonstrated by application to grid connections of off-shore wind power plants. Grid connection of an offshore wind power...... wind power plant employing HVDC. In the present study, a back to back HVDC transmission system is designed in PSCAD/EMTDC. Simulations and results showing the importance of high frequent modeling are presented....... plant using HVDC fundamentally changes the electrical environment for the power plant. Detailed knowledge and understanding of the characteristics and behavior of all relevant power system components under all conditions, including under transients, are required in order to develop reliable offshore...

  5. 77 FR 25472 - Amended Notice of Intent To Modify the Scope of the Environmental Impact Statement for the...

    Science.gov (United States)

    2012-04-30

    ... connect a 2,000-megawatt (MW) high-voltage direct current (HVDC) Voltage Source Converter (VSC... change in the project's design resulted in a proposed HVDC transmission line that would consist of a... alternative now consists of a single 1,000-MW HVDC bipole. The bipole is comprised of two connected submarine...

  6. ETR transmission systems

    International Nuclear Information System (INIS)

    Metzler, D.

    1983-01-01

    The presentation concentrates on factors associated with transmission systems for reactors and/or reactor relevant devices. For present day mirrors and their upgrades where power levels are in the few hundred kW range, waveguide systems with mode control are preferred. Beyond the early 1990's time frame are the ETR DEMO and reactor devices. These require injected power levels of about 75 MW. If only power oscillators are available at that time, then a MARS like transmission system may be appropriate or possibly a guided wave waveguide

  7. Passivity-Based Control of Multi-Terminal HVDC Systems under Control Saturation Constraints

    NARCIS (Netherlands)

    Doria-Cerezo, Arnau; Olm, Josep M.; Scherpen, Jacquelien M.A.

    2015-01-01

    This paper proposes a decentralized, passivity-based control design for power stations in a multi-terminal High Voltage Direct Current transmission system. The control algorithm is shown to asymptotically stabilize the closed-loop system when the voltage set points are appropriately selected. The

  8. Limiting electric fields of HVDC overhead power lines.

    Science.gov (United States)

    Leitgeb, N

    2014-05-01

    As a consequence of the increased use of renewable energy and the now long distances between energy generation and consumption, in Europe, electric power transfer by high-voltage (HV) direct current (DC) overhead power lines gains increasing importance. Thousands of kilometers of them are going to be built within the next years. However, existing guidelines and regulations do not yet contain recommendations to limit static electric fields, which are one of the most important criteria for HVDC overhead power lines in terms of tower design, span width and ground clearance. Based on theoretical and experimental data, in this article, static electric fields associated with adverse health effects are analysed and various criteria are derived for limiting static electric field strengths.

  9. Large-scale integration of wind power into power systems as well as on transmission networks for offshore wind power plants. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Betancourt, Uta; Ackermann, Thomas (eds.)

    2013-11-01

    This proceedings contains contributions to the followings main topics: Grid integration experiences; Flexibility and economics of integration; Voltage control issues; Offshore wind power plants; Forecasting; Grid code issues; HVDC connection issues; Frequency control issues; National grid's perspective; Power system balancing; Power system issues; New grid and generators issues; Flexibility with storage and demand side management; AC connected offshore wind power plants; Economic and market issues; Modelling issues; Offshore grid issues.

  10. Methods, apparatus, and systems for monitoring transmission systems

    Science.gov (United States)

    Polk, Robert E [Idaho Falls, ID; Svoboda, John M [Idaho Falls, ID; West, Phillip B [Idaho Falls, ID; Heath, Gail L [Iona, ID; Scott, Clark L [Idaho Falls, ID

    2010-08-31

    A sensing platform for monitoring a transmission system, and method therefor, may include a sensor that senses one or more conditions relating to a condition of the transmission system and/or the condition of an environment around the transmission system. A control system operatively associated with the sensor produces output data based on an output signal produced by the sensor. A transmitter operatively associated with the control system transmits the output data from the control system.

  11. Trends of HVDC technology - highly reliable converting equipment

    International Nuclear Information System (INIS)

    Muraoka, Yasuo; Kato, Yasushi; Watanabe, Atsumi; Kano, Takashi; Kawai, Tadao

    1983-01-01

    At present, the DC power transmission in Japan is practically used for the system connection of relatively small capacity, and the reliability of AC-DC converting system has been proven to exceed the world level by the operational results. However, when the application of this system to trunk power transmission of large capacity in future is considered, it is desirable to raise the reliability of converting equipment further and to develop the stabilized control techniques in harmony with connected AC system. Hitachi Ltd. has developed diversified system-related technologies centering around DC power transmission and the techniques for raising the reliability of converting equipment tending to large capacity. In this report, the results and the future prospect are described. The recent trend of DC power transmission, the development of DC power transmission technology such as the simulation analysis, the stable operation of a DC system connected to a weak AC system and the DC independent transmission from nuclear power stations, the technical development of light direct ignition thyristor bulbs and control protection equipment are reported. (Kako, I.)

  12. Capacitor voltage ripple reduction and arm energy balancing in MMC-HVDC

    DEFF Research Database (Denmark)

    Parikh, Harsh; Martin-Loeches, Ruben Sánches; Tsolaridis, Georgios

    2016-01-01

    Modular Multilevel Converters are emerging and widely used in HVDC applications. However, the submodule capacitors are still large and the energy balancing under unbalanced conditions is a challenge. In this paper, an analytical model focusing on the energy stored in the capacitors and voltage...... variations is utilized in order to achieve better performance. By injecting a second order harmonic component into the circulating current, the energy variation and consequently the capacitor voltage ripple is reduced allowing for a capacitor size reduction. At the same time, an arm energy balancing...

  13. Coordinated Voltage Control in Offshore HVDC Connected Cluster of Wind Power Plants

    DEFF Research Database (Denmark)

    Sakamuri, Jayachandra N.; Rather, Zakir Hussain; Rimez, Johan

    2016-01-01

    This paper presents a coordinated voltage control scheme (CVCS) for a cluster of offshore wind power plants (OWPPs) connected to a VSC HVDC system. The primary control point of the proposed voltage control scheme is the introduced Pilot bus, which is having the highest short circuit capacity...... in the offshore AC grid. The developed CVCS comprehends an optimization algorithm, aiming for minimum active power losses in the offshore grid, to generate voltage reference to the Pilot bus. During steady state operation, the Pilot bus voltage is controlled by dispatching reactive power references to each wind...... turbine (WT) in the WPP cluster based on their available reactive power margin and network sensitivity based participation factors, which are derived from the dV/dQ sensitivity of a WT bus w.r.t the Pilot bus. This method leads to minimization of the risk of undesired effects, particularly overvoltage...

  14. Technical and economic aspects of operation of thermal and hydro power systems

    Energy Technology Data Exchange (ETDEWEB)

    Bakken, Bjoern Harald

    1997-12-31

    This thesis studies system operation and operational costs of primary and secondary control in hydro and thermal power systems. The cost of providing primary control reserves in thermal power systems is estimated to 1-3% of total production cost. Hydro power units, on the other hand, provide a very cheap primary reserve compared to thermal units. The HVDC (High Voltage Direct Current) connection can be used for primary control in either direction but the thesis only considers substitution of reserves in the thermal system with reserves from the hydro system. Since the HVDC connection is easy to control, the transient characteristics are considerably improved, and one can substitute an amount of thermal spinning reserve corresponding to the available HVDC capacity with little disturbance in any system. A more realistic alternative, at present, is to sell secondary control reserves across the HVDC connections. Keeping spinning reserve for automatic secondary control in a thermal power system is estimated to cost 3-5% of total production cost. Secondary control reserves probably cannot compete with the value of the peak load export, but one should seriously consider using part of the HVDC capacity as secondary control reserve for the thermal system during off-peak hours with. The author discusses the concept of automatic secondary control both theoretically and by simulations and finds that there are no special technical difficulties in introducing automatic secondary control in the Nordel (an organization for Nordic power cooperation) system. 78 refs., 4 figs., 23 tabs.

  15. Technical and economic aspects of operation of thermal and hydro power systems

    Energy Technology Data Exchange (ETDEWEB)

    Bakken, Bjoern Harald

    1998-12-31

    This thesis studies system operation and operational costs of primary and secondary control in hydro and thermal power systems. The cost of providing primary control reserves in thermal power systems is estimated to 1-3% of total production cost. Hydro power units, on the other hand, provide a very cheap primary reserve compared to thermal units. The HVDC (High Voltage Direct Current) connection can be used for primary control in either direction but the thesis only considers substitution of reserves in the thermal system with reserves from the hydro system. Since the HVDC connection is easy to control, the transient characteristics are considerably improved, and one can substitute an amount of thermal spinning reserve corresponding to the available HVDC capacity with little disturbance in any system. A more realistic alternative, at present, is to sell secondary control reserves across the HVDC connections. Keeping spinning reserve for automatic secondary control in a thermal power system is estimated to cost 3-5% of total production cost. Secondary control reserves probably cannot compete with the value of the peak load export, but one should seriously consider using part of the HVDC capacity as secondary control reserve for the thermal system during off-peak hours with. The author discusses the concept of automatic secondary control both theoretically and by simulations and finds that there are no special technical difficulties in introducing automatic secondary control in the Nordel (an organization for Nordic power cooperation) system. 78 refs., 4 figs., 23 tabs.

  16. Technical and economic aspects of operation of thermal and hydro power systems

    International Nuclear Information System (INIS)

    Bakken, Bjoern Harald.

    1997-01-01

    This thesis studies system operation and operational costs of primary and secondary control in hydro and thermal power systems. The cost of providing primary control reserves in thermal power systems is estimated to 1-3% of total production cost. Hydro power units, on the other hand, provide a very cheap primary reserve compared to thermal units. The HVDC (High Voltage Direct Current) connection can be used for primary control in either direction but the thesis only considers substitution of reserves in the thermal system with reserves from the hydro system. Since the HVDC connection is easy to control, the transient characteristics are considerably improved, and one can substitute an amount of thermal spinning reserve corresponding to the available HVDC capacity with little disturbance in any system. A more realistic alternative, at present, is to sell secondary control reserves across the HVDC connections. Keeping spinning reserve for automatic secondary control in a thermal power system is estimated to cost 3-5% of total production cost. Secondary control reserves probably cannot compete with the value of the peak load export, but one should seriously consider using part of the HVDC capacity as secondary control reserve for the thermal system during off-peak hours with. The author discusses the concept of automatic secondary control both theoretically and by simulations and finds that there are no special technical difficulties in introducing automatic secondary control in the Nordel (an organization for Nordic power cooperation) system. 78 refs., 4 figs., 23 tabs

  17. Fault Diagnosis and Fault-tolerant Control of Modular Multi-level Converter High-voltage DC System

    DEFF Research Database (Denmark)

    Liu, Hui; Ma, Ke; Wang, Chao

    2016-01-01

    of failures and lower the reliability of the MMC-HVDC system. Therefore, research on the fault diagnosis and fault-tolerant control of MMC-HVDC system is of great significance in order to enhance the reliability of the system. This paper provides a comprehensive review of fault diagnosis and fault handling...

  18. Active Power Control with Undead-Band Voltage & Frequency Droop for HVDC Converters in Large Meshed DC Grids

    DEFF Research Database (Denmark)

    Vrana, Til Kristian; Zeni, Lorenzo; Fosso, Olav Bjarte

    A new control method for large meshed HVDC grids has been developed, which helps to keep the active power balance at the AC and the DC side. The method definition is kept wide, leaving the possibility for control parameter optimisation. Other known control methods can be seen as specific examples...

  19. Decreasing the commutation failure frequency in HVDC transmission systems

    DEFF Research Database (Denmark)

    Hansen (retired June, 2000), Arne; Havemann (retired June, 2000), Henrik

    2000-01-01

    In this paper we show how a fairly large proportion of those commutation failures that are due to single-phased short circuits to earth can be avoided. In a control circuit based on a digital signal processor (DSP) it is possible, with instantaneous results, to switch from a normal control strategy...... with equidistant firing pulses to a strategy that takes into consideration the potentially dangerous voltage changes on the supply lines, If the supply voltages are monitored continuously, it is possible to calculate the necessity of advancing the firing pulses to avoid commutation failures. In the paper...

  20. AREVA T and D wins de-icing contract in Quebec

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2005-04-01

    The ice storm that struck Quebec in the winter of 1998 left millions of people without electricity because the accumulation of ice caused the collapse of hundreds of kilometres of high-voltage transmission lines and thousands of transmission towers. In order to optimize the security of its power grid, Hydro-Quebec contracted AREVA T and D to construct and install HVDCice{sup TM}, a transmission line de-icing system based on high-voltage direct current (HVDC) technology. The system is intended to ensure maximum electrical efficiency and guarantee a secure electricity supply. The system will generate up to 7200A of direct current in the transmission lines. This will raise their temperature thereby allowing the ice to melt and fall off. The system will be implemented at the Levis substation, a major connection point for the transmission lines of the province. The system also acts as a Static Var Compensator (SVC) to improve the power quality of the transmission network. The SVC will stabilize the voltage on the 735 kV power grid, which can fluctuate depending on the amount of electricity being consumed. This is the world's first HVDC-based de-icing and power quality system. The contract awarded to AREVA's T and D division is estimated at 25 million Euros. 1 fig.

  1. Behavior of highly diluted electrolytes in strong electric fields-prevention of alumina deposition on grading electrodes in HVDC transmission modules by CO2-induced pH-control.

    Science.gov (United States)

    Weber, Immo; Mallick, Bert; Schild, Matthias; Kareth, Sabine; Puchta, Ralph; van Eldik, Rudi

    2014-09-15

    Alumina deposition on platinum grading electrodes in high voltage direct current (HVDC) transmission modules is an unsolved problem that has been around for more than three decades. This is due to the unavoidable corrosion of aluminum heat sinks that causes severe damage to electrical power plants and losses in the range of a million Euro range per day in power outage. Simple experiments in a representative HV test setup showed that aluminates at concentrations even below 10(-8) mol L(-1) can deposit on anodes through neutralization by protons produced in de-ionized water (κ≤0.15 μS cm(-1)) at 20-35 kV (8 mA) per electrode. In this otherwise electrolyte-poor aqueous environment, the depositions are formed three orders of magnitude below the critical precipitation concentration at pH 7! In the presence of an inert electrolyte such as TMAT (tetramethylammonium-p-toluenesulfonate), at a concentration level just above that of the total dissolved aluminum, no deposition was observed. Deposition can be also prevented by doping with CO2 gas at a concentration level that is magnitudes lower than that of the dissolved aluminum. From an overview of aqueous aluminum chemistry, the mystery of the alumina deposition process and its inhibition by CO2 is experimentally resolved and fully explained by field accumulation and repulsion models in synergism with acid-base equilibria. The extraordinary size of the alumina depositions is accounted for in terms of proton tunneling through "hydrated" alumina, which is supported by quantum chemical calculations. As a consequence, pulse-purging with pure CO2 gas is presented as a technical solution to prevent the deposition of alumina. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Renewables integration, flexibility measures and operational tools for the Ireland and Northern Ireland power system

    International Nuclear Information System (INIS)

    Flynn, Damian; Power, Michael; O'Malley, Mark

    2016-01-01

    The Ireland and Northern Ireland power system is pursuing ambitious renewable energy (mainly wind generation) targets for 2020. A range of system-wide initiatives are being developed as part of the DS3 (Delivering a Secure, Sustainable Electricity System) programme, and, in particular, a bespoke suite of ancillary services incentivising fast frequency response, dynamic reactive power and ramping margin, and other, (future) system needs. With approximately half of the wind generation connected at distribution level, network development at both distribution and transmission levels is a key challenge for both the transmission system operators (TSO) and distribution system operators (DSO): a wide range of technical options are being examined, including under-grounding, HVDC connection and series compensation, supported by a public and stakeholder engagement programme. The experience gained is highlighted, while also indicating solutions and strategies which have been proposed, and ongoing challenges for the future. (Authors)

  3. An offshore wind farm with dc grid connection and its performance under power system transients

    DEFF Research Database (Denmark)

    Deng, Fujin; Chen, Zhe

    2011-01-01

    by disconnections. This paper presents a transient performance study of an offshore wind farm with HVDC transmission for grid connection, where the wind turbines in the offshore wind farm are also connected with dc collection network. A power-reduction control strategy (PRCS) for transient performance improvement...

  4. Fault Ride-through Capability Enhancement of Voltage Source Converter-High Voltage Direct Current Systems with Bridge Type Fault Current Limiters

    Directory of Open Access Journals (Sweden)

    Md Shafiul Alam

    2017-11-01

    Full Text Available This paper proposes the use of bridge type fault current limiters (BFCLs as a potential solution to reduce the impact of fault disturbance on voltage source converter-based high voltage DC (VSC-HVDC systems. Since VSC-HVDC systems are vulnerable to faults, it is essential to enhance the fault ride-through (FRT capability with auxiliary control devices like BFCLs. BFCL controllers have been developed to limit the fault current during the inception of system disturbances. Real and reactive power controllers for the VSC-HVDC have been developed based on current control mode. DC link voltage control has been achieved by a feedback mechanism such that net power exchange with DC link capacitor is zero. A grid-connected VSC-HVDC system and a wind farm integrated VSC-HVDC system along with the proposed BFCL and associated controllers have been implemented in a real time digital simulator (RTDS. Symmetrical three phase as well as different types of unsymmetrical faults have been applied in the systems in order to show the effectiveness of the proposed BFCL solution. DC link voltage fluctuation, machine speed and active power oscillation have been greatly suppressed with the proposed BFCL. Another significant feature of this work is that the performance of the proposed BFCL in VSC-HVDC systems is compared to that of series dynamic braking resistor (SDBR. Comparative results show that the proposed BFCL is superior over SDBR in limiting fault current as well as improving system fault ride through (FRT capability.

  5. Experimental Investigation of the Corona Discharge in Electrical Transmission due to AC/DC Electric Fields

    Directory of Open Access Journals (Sweden)

    Fuangpian Phanupong

    2016-01-01

    Full Text Available Nowadays, using of High Voltage Direct Current (HVDC transmission to maximize the transmission efficiency, bulk power transmission, connection of renewable power source from wind farm to the grid is of prime concern for the utility. However, due to the high electric field stress from Direct Current (DC line, the corona discharge can easily be occurred at the conductor surface leading to transmission loss. Therefore, the polarity effect of DC lines on corona inception and breakdown voltage should be investigated. In this work, the effect of DC polarity and Alternating Current (AC field stress on corona inception voltage and corona discharge is investigated on various test objects, such as High Voltage (HV needle, needle at ground plane, internal defect, surface discharge, underground cable without cable termination, cable termination with simulated defect and bare overhead conductor. The corona discharge is measured by partial discharge measurement device with high-frequency current transformer. Finally, the relationship between supply voltage and discharge intensity on each DC polarity and AC field stress can be successfully determined.

  6. 47 CFR 73.6023 - Distributed transmission systems.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Distributed transmission systems. 73.6023... distributed transmission system. [73 FR 74064, Dec. 5, 2008] ... RADIO BROADCAST SERVICES Class A Television Broadcast Stations § 73.6023 Distributed transmission...

  7. Design, construction and testing of a DC bioeffects test enclosure for small animals. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Frazier, M J; Preache, M M

    1980-11-01

    This final report describes both the engineering development of a DC bioeffects test enclosure for small laboratory animals, and the biological protocol for the use of such enclosures in the testing of animals to determine possible biological effects of the environment associated with HVDC transmission lines. The test enclosure which has been designed is a modular unit, which will house up to eight rat-sized animals in individual compartments. Multiple test enclosures can be used to test larger numbers of animals. A prototype test enclosure has been fabricated and tested to characterize its electrical performance characteristics. The test enclosure provides a simulation of the dominant environment associated with HVDC transmission lines; namely, a static electric field and an ion current density. A biological experimental design has been developed for assessing the effects of the dominant components of the HVDC transmission line environment.

  8. Rain and contamination tests on HVDC wall bushings with and without RTV coatings

    International Nuclear Information System (INIS)

    Schneider, H.M.; Hall, J.F.; Nellis, C.L.; Low, S.S.; Lorden, D.J.

    1991-01-01

    In this paper results of tests made to determine the ability of room temperature vulcanized (RTV) silicone rubber coatings to improve the performance of HVDC wall bushings are described. The behavior of uncoated full scale ± 500 kV wall bushings is first determined in wetting conditions consisting of nonuniform rain and fog with various amounts of pre-deposited surface contamination. Parameters affecting flashover performance, such as polarity, rain conductivity, and contamination severity are discussed. Results of nonuniform rain tests on an RTV coated wall bushing are reported

  9. Topics in lightwave transmission systems

    CERN Document Server

    Li, Tingye

    1991-01-01

    Topics in Lightwave Transmission Systems is a second volume of a treatise on optical fiber communications that is devoted to the science, engineering, and application of information transmission via optical fibers. The first volume, published in 1985, dealt exclusively with fiber fabrication. The present volume contains topics that pertain to subsystems and systems. The book contains five chapters and begins with discussions of transmitters and receivers, which are basic to systems now operating in the field. Subsequent chapters cover topics relating to coherent systems: frequency and phase m

  10. Fiscal 1999 research result report on energy and environment technology demonstration research support project (International joint demonstration research project). Japan- Russia joint demonstration research on large-capacity long- distant DC power transmission technology; 1999 nendo daiyoryo denryoku no chokyori chokuryu soden gijutsu ni kansuru Russia kenkyu kikan tono kyodo jissho kenkyu seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    Under the assumption of a large-capacity DC power transmission model project in the Far East and Siberia districts, technical study was made on the basic design of the project, considering selection of concrete power generation and consumption sites and power transmission routes, power transmission/transformation equipment, cables, and environmental impact. Study was also made on its applicability to similar projects in Japan. The model project aims at integration of Eastern Integrated Power System in the Far East and Russian Unified Power System, and development of abundant undeveloped hydraulic and tidal power generation in the Far East. The study result showed that (1) construction of the high-voltage DC power transmission (HVDC) system of model project class voltage and capacity in Eastern Siberia is possible technically enough, (2) the total construction cost of the model project scheduled to be put into operation in 2025 amounts to nearly $4.7 billion, and (3) the model project is environment-friendly without any CO{sub 2} gas emission because of hydraulic and tidal power generation. (NEDO)

  11. Digital model for harmonic interactions in AC/DC/AC systems

    Energy Technology Data Exchange (ETDEWEB)

    Guarini, A P; Rangel, R D; Pilotto, L A.S.; Pinto, R J; Passos, Junior, R [Centro de Pesquisas de Energia Eletrica (CEPEL), Rio de Janeiro, RJ (Brazil)

    1994-12-31

    The main purpose of this paper is to present a model for calculation of HVdc converter harmonics taking into account the influence of the harmonic interactions between the ac systems in dc link transmissions. The ideas and methodologies used in the model development take into account the dc current ripple and ac voltage distortion in the ac systems. The theory of switching functions is applied to contemplate for the frequency conversions between the ac and dc sides, in an iterative process. It is possible then to obtain, even in balanced situations, non-characteristic harmonics that are produced by frequencies originated in the other terminal, which can be significant in a strongly coupled system, such as back-to-back configuration. (author) 9 refs., 3 figs.

  12. The paradox of transmission system value

    International Nuclear Information System (INIS)

    Haddad, S.Z.; Feldman, R.D.; Charnetzki, P.

    1995-01-01

    The central importance of utility strategic planning with respect to transmission systems has developed as a result of the passage of the Energy Policy Act and the rapid emergence of the era of open grid access. As a consequence, utilities have had to redefine transmission as being more than a cost center managed with reliability as the principal focus and regulated on a rate of return basis. Transmission must now be managed with a view to protection of customers, where possible, and to revenue maximization, both through pricing strategy and through operations. This shift has been compounded by the pressures being thrust upon utilities by regulators or being fomented by competitors to unbundle transmission and distribution from generation. This paper explores how the value of the transmission system can be viewed from the vantage points of different organizations (utilities, regulators, customers, independent generators, etc.). The paper addresses the uncertain and apparently paradoxical nature of transmission system value as it will be impacted by the possible alternative future structures of the electric power industry. Lastly, this paper suggests the strategic possibilities for utilities that this uncertainty presents

  13. Analysis of different power grid segmentation and transmission schemes for power system security improvement

    International Nuclear Information System (INIS)

    Shami, U.T.; Chaudhary, M.S.

    2015-01-01

    This paper explores the power grid segmentation concept for power system stability improvement in detail. First, the firewall property of grid segmentation is investigated for a two area network. Then two HVDC technologies, LCC and VSC, are compared for the same network. A two area VSC-AC segmented network is then compared with two area VSC segmented network. Suitable segmentation topology and suitable number of VSC segmented areas are then investigated. Simulation results show that grid segmentation offers network stability during fault conditions and VSC is the most suitable choice for segmentation over LCC. Results further show that having large number of DC segmented areas and using the radial segmentation topology improves the stability of the overall system. All the simulations were carried out in PSS at the rate E software provided by SIEMENS discussed. Section IV discusses the test systems under study in this research. Section V compares and analyzes the simulation results. Section VI contains the conclusion. (author)

  14. Storage- and grid expansion needs in a European electricity-supply-system with a high share of renewable energy

    Energy Technology Data Exchange (ETDEWEB)

    Thien, Tjark; Cai, Zhuang [RWTH Aachen Univ. (Germany). Inst. for Power Generation and Storage Systems (PGS), E.ON ERC; Juelich Aachen Research Alliance, JARA-Energy (Germany); Alvarez, Ricardo; Awater, Philipp; Moser, Albert [RWTH Aachen Univ. (Germany). Chair and Inst. of Power Systems and Power Economics (IAEW); Juelich Aachen Research Alliance, JARA-Energy (Germany); Leuthold, Matthias; Sauer, Dirk Uwe [RWTH Aachen Univ. (Germany). Electrochemical Energy Conversion and Storage Systems Group; RWTH Aachen Univ. (Germany). Inst. for Power Generation and Storage Systems (PGS), E.ON ERC; Juelich Aachen Research Alliance, JARA-Energy (Germany)

    2012-07-01

    The transformation of the European electricity supply system to fully supply from renewable energy sources (RES), which is associated with the German ''Energiewende'', brings up the question how RES could be optimally allocated throughout Europe in order to minimize the total generation costs. For this task, an optimization tool based on a genetic algorithm was developed. The tool is able to optimize the capacity and allocation of RES, storage system and transmission network in a given energy system in order to get minimal overall economic costs. Exemplary results for the EUMENA region (Europe, Middle East and North Africa) show an optimal RES installed capacity of 2913 MW (Wind and PV),a storage capacity of 325 TWh and the installation of an HVDC overlay-grid with 1,140,000 GWkm transmission capacity. If such a system was realized, costs of 11.9 Eurocent per consumed Kilowatt-hour would occur.

  15. ECRH transmission system

    International Nuclear Information System (INIS)

    Tancredi, J.

    1983-01-01

    Hughes, Electron Dynamics Division is developing gyrotrons for ECRH requirements. In the development program, techniques have been evolved for transmission system components. These techniques include over-moded waveguide tapers, high average power windows, and rf water loads for testing

  16. 47 CFR 73.626 - DTV distributed transmission systems.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false DTV distributed transmission systems. 73.626... RADIO BROADCAST SERVICES Television Broadcast Stations § 73.626 DTV distributed transmission systems. (a... distributed transmission system (DTS). Except as expressly provided in this section, DTV stations operating a...

  17. Opportunities and Benefits for Increasing Transmission Capacity between the US Eastern and Western Interconnections

    Science.gov (United States)

    Figueroa-Acevedo, Armando L.

    Historically, the primary justification for building wide-area transmission lines in the US and around the world has been based on reliability and economic criteria. Today, the influence of renewable portfolio standards (RPS), Environmental Protection Agency (EPA) regulations, transmission needs, load diversity, and grid flexibility requirements drives interest in high capacity wide-area transmission. By making use of an optimization model to perform long-term (15 years) co-optimized generation and transmission expansion planning, this work explored the benefits of increasing transmission capacity between the US Eastern and Western Interconnections under different policy and futures assumptions. The model assessed tradeoffs between investments in cross-interconnection HVDC transmission, AC transmission needs within each interconnection, generation investment costs, and operational costs, while satisfying different policy compliance constraints. Operational costs were broken down into the following market products: energy, up-/down regulation reserve, and contingency reserve. In addition, the system operating flexibility requirements were modeled as a function of net-load variability so that the flexibility of the non-wind/non-solar resources increases with increased wind and solar investment. In addition, planning reserve constraints are imposed under the condition that they be deliverable to the load. Thus, the model allows existing and candidate generation resources for both operating reserves and deliverable planning reserves to be shared throughout the interconnections, a feature which significantly drives identification of least-cost investments. This model is used with a 169-bus representation of the North American power grid to design four different high-capacity wide-area transmission infrastructures. Results from this analysis suggest that, under policy that imposes a high-renewable future, the benefits of high capacity transmission between the Eastern and

  18. Analysis of dynamic behavior of the back-to-back High Voltage Direct Current link model as part of electrical power system

    Directory of Open Access Journals (Sweden)

    Rudnik Vladimir

    2017-01-01

    Full Text Available One of the main directions of the development of electric power systems is the introduction of technologies based on high-power semiconductor switches, such as FACTS devices and HVDC technologies. These systems effectively solve a number of urgent tasks of EPS, connected with asynchronous connection of EPS, transmission of electricity, improve local and systemic flexibility and reliability of EPS, increasing the capacity of network elements that contains a “weak” connection. However, the implementation and operation of mentioned technologies in the EPS determines the need for a wide range of analysis and research that can only be done with the help of mathematical modeling.

  19. Hybrid-Vehicle Transmission System

    Science.gov (United States)

    Lupo, G.; Dotti, G.

    1985-01-01

    Continuously-variable transmission system for hybrid vehicles couples internal-combustion engine and electric motor section, either individually or in parallel, to power vehicle wheels during steering and braking.

  20. Introduction of hvdc transmission into a predominantly ac network

    Energy Technology Data Exchange (ETDEWEB)

    Casson, W; Last, F H; Huddart, K W

    1966-02-01

    Methods for reinforcing the supply network, including systems employing dc links, without introducing a new primary network are briefly described. The arrangement for dc links is outlined and the application to an existing ac system is considered. The economics of ac and dc for reinforcement schemes are briefly mentioned.

  1. Insulation Coordination of Arcing Horns on HVDC Electrode Lines: Protection Performance Evaluation, Influence Factors and Improvement Method

    Directory of Open Access Journals (Sweden)

    Xiandong Li

    2018-02-01

    Full Text Available Arcing horns are widely used in high voltage overhead lines to protect insulator strings from being destroyed by the free burning arcs caused by lightening faults. In this paper, we focus on the insulation coordination of arcing horns on the electrode lines of a 5000 MW, ±800 kV high voltage direct current (HVDC system. The protection performance of arcing horns are determined by the characteristics of not only the external system but also the fault arc. Therefore, the behaviors and characteristics of long free burning arcs are investigated by the experiments at first. In order to evaluate the protection performance of arcing horns, the static stability criterion U-I characteristic method is introduced. The influence factors on the protection performance of arcing horns are analyzed theoretically. Finally, the improvement methods for the protection performance of arcing horns are proposed, and the diversified configuration strategy of arcing horns is recommended for cost saving.

  2. Priority Control Strategy of VSC-MTDC System for Integrating Wind Power

    Directory of Open Access Journals (Sweden)

    Wen-ning Yan

    2015-01-01

    Full Text Available For the obvious advantages in integrating wind power, multiterminal HVDC transmission system (VSC-MTDC is widely used. The priority control strategy is proposed in this paper considering the penetration rate of wind power for the AC grid. The strategy aims to solve the problems of power allocation and DC voltage control of the DC system. The main advantage of this strategy is that the demands for wind power of different areas can be satisfied and a power reference for the wind power trade can also be provided when wind farms transmit active power to several AC grids through the DC network. The objective is that power is well distributed according to the output power of wind farm with the demand of AC system and satisfactory control performance of DC voltage is obtained.

  3. Multi-core fiber undersea transmission systems

    DEFF Research Database (Denmark)

    Nooruzzaman, Md; Morioka, Toshio

    2017-01-01

    Various potential architectures of branching units for multi-core fiber undersea transmission systems are presented. It is also investigated how different architectures of branching unit influence the number of fibers and those of inline components.......Various potential architectures of branching units for multi-core fiber undersea transmission systems are presented. It is also investigated how different architectures of branching unit influence the number of fibers and those of inline components....

  4. Eco-design of power transmissions systems

    International Nuclear Information System (INIS)

    Wang, W.

    2011-01-01

    The demand to preserve the environment and form a sustainable development is greatly increasing in the recent decades all over the world, and this environmental concern is also merged in electrical power industry, resulting in many eco-design approaches in Transmission and Distribution (T and D) industries. As a method of eco-design, Life Cycle Assessment (LCA) is a systematic tool that enables the assessment of the environmental impacts of a product or service throughout its entire life cycle, i.e. raw material production, manufacture, distribution, use and disposal including all intervening transportation steps necessary or caused by the product's existence. In T and D industries, LCA has been done for a lot of products individually, in order to see one product's environmental impacts and to seek for ways of improving its environmental performance. This eco-design for product approach is a rather well-developed trend, however, as only a single electrical product cannot provide the electrical power to users, electrical system consists of a huge number of components, in order to investigate system's environmental profile, the entire environmental profiles of different composing products has to be integrated systematically, that is to say, a system approach is needed. Under this philosophy, the study 'Eco-design of Power Transmission Systems' is conducted in this thesis, with the purpose of analysing the transmission systems' environmental impacts, locating the major environmental burden sources of transmission systems, selecting and/or developing methodologies of reducing its environmental impacts. (author)

  5. Thyristors for dc transmission

    Energy Technology Data Exchange (ETDEWEB)

    1966-05-06

    As a first stage towards determining the feasibility of applying thyristors to hvdc converter terminals, the Westinghouse Electric Corporation has built a converter laboratory capable of testing thyristors under conditions similar to those which would have to be met in a 200 kV dc system. The equipment has been designed to test a 5 kV 600 A group of thyrisotrs, elevated 200 kV above earth. This rating has been chosen so that there would be a sufficient number of thyristors in series to enable the gating and voltage division characteristics to be investigated and at the same time the group could be operated at a potential equivalent to a complete 200 kV dc bridge.

  6. 47 CFR 73.1350 - Transmission system operation.

    Science.gov (United States)

    2010-10-01

    ... interference. (e) If a broadcast station is operating in a manner that poses a threat to life or property or... 47 Telecommunication 4 2010-10-01 2010-10-01 false Transmission system operation. 73.1350 Section... RADIO BROADCAST SERVICES Rules Applicable to All Broadcast Stations § 73.1350 Transmission system...

  7. Microwave energy transmission system for solar power station

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Hiroshi

    1988-05-05

    This paper deals with a microwave wireless energy transmission system which will be required for a solar power station under investigation, particularly, it describes its foundation and future investigation. It is supposed that for realization of microwave wireless transmission techniques, it is most important to investigate the effect of strong microwave beams on a plasma environment, establish control techniques for microwave beams in which a retro-directive system is combined with a computer control system, and develop a semiconductor transmission module. Institute of Space and Astronautical Science (Japan) made an experiment on the effect of microwaves on ionospheric plasma by using an observatory rocket. The institute has planned to make an experiment on a microwave energy transmission system which is to be mounted to a small-scale space flyer unit in order to examine the control of microwave beams and 10 KW power transmission, in addition to investigation on the interaction of microwave energy beams with a plasma environment. (4 figs, 3 tabs, 20 refs)

  8. A new data transmission system for deep water applications

    International Nuclear Information System (INIS)

    Brown, Gerald K.

    2000-01-01

    A novel data transmission system is now available. Conventional data transmission methods include systems that require satellites, hard wires, fiber optics and other methods that do not lend themselves to buried, remote, or deep water applications. The Data Transmission System (DTS) induces a signal into a structure such as the transmission line and retrieving the signal at a distant point. In deep water applications the power required comes from an anode array that generates its own power. In addition to deep water applications, the DTS can be used in onshore, drilling, and downhole applications. With repeater stations, most lengths of gathering and transmission lines can be used. Therefore data from control valves, strain gauges, corrosion monitoring, sand monitoring, valve position and other process variables can all be transmitted. Comparisons are made between the different data transmission systems showing the advantages and disadvantages of each type with comparative costs showing the advantages of the new DTS system. (author)

  9. INFORMATION-MEASURING TEST SYSTEM OF DIESEL LOCOMOTIVE HYDRAULIC TRANSMISSIONS

    Directory of Open Access Journals (Sweden)

    I. V. Zhukovytskyy

    2015-08-01

    Full Text Available Purpose. The article describes the process of developing the information-measuring test system of diesel locomotives hydraulic transmission, which gives the possibility to obtain baseline data to conduct further studies for the determination of the technical condition of diesel locomotives hydraulic transmission. The improvement of factory technology of post-repair tests of hydraulic transmissions by automating the existing hydraulic transmission test stands according to the specifications of the diesel locomotive repair enterprises was analyzed. It is achieved based on a detailed review of existing foreign information-measuring test systems for hydraulic transmission of diesel locomotives, BelAZ earthmover, aircraft tug, slag car, truck, BelAZ wheel dozer, some brands of tractors, etc. The problem for creation the information-measuring test systems for diesel locomotive hydraulic transmission is being solved, starting in the first place from the possibility of automation of the existing test stand of diesel locomotives hydraulic transmission at Dnipropetrovsk Diesel Locomotive Repair Plant "Promteplovoz". Methodology. In the work the researchers proposed the method to create a microprocessor automated system of diesel locomotives hydraulic transmission stand testing in the locomotive plant conditions. It acts by justifying the selection of the necessary sensors, as well as the application of the necessary hardware and software for information-measuring systems. Findings. Based on the conducted analysis there was grounded the necessity of improvement the plant hydraulic transmission stand testing by creating a microprocessor testing system, supported by the experience of developing such systems abroad. Further research should be aimed to improve the accuracy and frequency of data collection by adopting the more modern and reliable sensors in tandem with the use of filtering software for electromagnetic and other interference. Originality. The

  10. Dynamic Reactive Power Control in Offshore HVDC Connected Wind Power Plants

    DEFF Research Database (Denmark)

    Sakamuri, Jayachandra N.; Cutululis, Nicolaos Antonio; Rather, Zakir Hussain

    2016-01-01

    This paper presents a coordinated reactive power control for a HVDC connected cluster of offshore wind power plants (WPPs). The reactive power reference for the WPP cluster is estimated by an optimization algorithm aiming at minimum active power losses in the offshore AC Grid. For each optimal......, such as wind turbine (WT) terminal, collector cable, and export cable, on the dynamic voltage profile of the offshore grid is investigated. Furthermore, the dynamic reactive power contribution from WTs from different WPPs of the cluster for such faults has also been studied....... reactive power set point, the OWPP cluster controller generates reactive power references for each WPP which further sends the AC voltage/ reactive power references to the associated WTs based on their available reactive power margin. The impact of faults at different locations in the offshore grid...

  11. Considering system non-linearity in transmission pricing

    International Nuclear Information System (INIS)

    Oloomi-Buygi, M.; Salehizadeh, M. Reza

    2008-01-01

    In this paper a new approach for transmission pricing is presented. The contribution of a contract on power flow of a transmission line is used as extent-of-use criterion for transmission pricing. In order to determine the contribution of each contract on power flow of each transmission line, first the contribution of each contract on each voltage angle is determined, which is called voltage angle decomposition. To this end, DC power flow is used to compute a primary solution for voltage angle decomposition. To consider the impacts of system non-linearity on voltage angle decomposition, a method is presented to determine the share of different terms of sine argument in sine value. Then the primary solution is corrected in different iterations of decoupled Newton-Raphson power flow using the presented sharing method. The presented approach is applied to a 4-bus test system and IEEE 30-bus test system and the results are analyzed. (author)

  12. WECC Variable Generation Planning Reference Book: Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Makarov, Yuri V.; Du, Pengwei; Etingov, Pavel V.; Ma, Jian; Vyakaranam, Bharat

    2013-05-13

    The document titled “WECC Variable Generation Planning Reference Book”. This book is divided into two volumes; one is the main document (volume 1)and the other is appendices (volume 2). The main document is a collection of the best practices and the information regarding the application and impact of variables generation on power system planning. This volume (appendices) has additional information on the following topics: Probabilistic load flow problems. 2. Additional useful indices. 3. high-impact low-frequency (HILF) events. 4. Examples of wide-area nomograms. 5. Transmission line ratings, types of dynamic rating methods. 6. Relative costs per MW-km of different electric power transmission technologies. 7. Ultra-high voltage (UHV) transmission. 8.High voltage direct current (VSC-HVDC). 9. HVDC. 10. Rewiring of existing transmission lines. 11. High-temperature low sag (HTLS) conductors. 12. The direct method and energy functions for transient stability analysis in power systems. 13.Blackouts caused by voltage instability. 14. Algorithm for parameter continuation predictor-corrector methods. 15. Approximation techniques available for security regions. 16. Impacts of wind power on power system small signals stability. 17. FIDVR. 18. FACTS. 19. European planning standard and practices. 20. International experience in wind and solar energy sources. 21. Western Renewable Energy Zones (WREZ). 22. various energy storage technologies. 23. demand response. 24. BA consolidation and cooperation options. 25. generator power management requirements and 26. European planning guidelines.

  13. Erratum: Erratum to Central European Journal of Engineering, Volume 4, Issue 1

    Science.gov (United States)

    Kumar, M. Ajay; Srikanth, N. V.

    2014-06-01

    Paper by M. Ajay Kumar, N. V. Srikanth, et al. "An adaptive neuro fuzzy inference system controlled space cector pulse width modulation based HVDC light transmission system under AC fault conditions" in Volume 4, Issue 1, 27-38/March 2014 doi: 10.2478/s13531-013-0143-4 contains an error in the title. The correct title is presented below

  14. Coupling and corona effects research plan for transmission lines. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Bridges, J E; Formanek, V C

    1976-06-01

    Concern has arisen over the possible effects of electric and magnetic fields produced by EHV-UHV transmission lines. Past and ongoing research concerning the electric and magnetic field effects from EHV-UHV transmission lines was reviewed as it pertains to the following areas: (1) electromagnetic interference, (2) acoustic noise, (3) generation of gaseous effluents, and (4) safety considerations of induced voltages and currents. The intent of this review was to identify the short and long range research projects required to address these areas. The research plan identifies and gives priority to twenty programs in corona and coupling effects. In the case of the corona effects, a number of programs were recommended for acoustic noise and electromagnetic interference to delineate improved power line design criteria in terms of social, meteorological, geographical and cost constraints. Only one project is recommended in the case of ozone generation, because the results of comprehensive analyses, laboratory studies and field measurements have demonstrated that power lines do not contribute significant quantities of ozone. In the case of the coupling effects, a number of programs are recommended for HVAC transmission lines to improve the theoretically developed design guidelines by considering practical constraints. For HVDC transmission lines, programs are suggested to engender a better theoretical understanding and practical measurements capability for the coupling mechanisms of the dc electric and magnetic field with nearby objects. The interrelationship of the programs and their role in a long-term research plan is also discussed.

  15. Microwave transmission system for space power

    Energy Technology Data Exchange (ETDEWEB)

    Dickinson, R M [Jet Propulsion Lab., Pasadena, Calif. (USA)

    1976-09-01

    A small total system model and a large subsystem element similar to those that could be eventually used for wireless power transmission experiments in space have been successfully demonstrated by NASA. The short range, relatively low-power laboratory system achieved a dc-to-dc transmission efficiency of 54%. A separate high-power-level receiving subsystem, tested over a 1.54-km range at Goldstone, California, has achieved the transportation of over 30 kW of dc output power. Both tests used 12-cm wave-length microwaves.

  16. Multicore fibers for high-capacity submarine transmission systems

    DEFF Research Database (Denmark)

    Nooruzzaman, Md.; Morioka, Toshio

    2018-01-01

    Applications of multicore fibers (MCFs) in undersea transmission systems are investigated, and various potential architectures of branching units for MCF-based undersea transmission systems are presented. Some MCF-based submarine network architectures based on the amount of data traffic are also...

  17. Strategic Generation with Conjectured Transmission Price Responses in a Mixed Transmission Pricing System. Part 2. Application

    International Nuclear Information System (INIS)

    Wals, A.F.; Hobbs, B.F.; Rijkers, F.A.M.

    2004-05-01

    The conjectured transmission price response model presented in the first of this two-paper series considers the expectations of oligopolistic generators regarding how demands for transmission services affect the prices of those services. Here, the model is applied to northwest Europe, simulating a mixed transmission pricing system including export fees, a path-based auction system for between-country interfaces, and implicit congestion-based pricing of internal country constraints. The path-based system does not give credit for counterflows when calculating export capability. The application shows that this no-netting policy can exacerbate the economic inefficiencies caused by oligopolistic pricing by generators. The application also illustrates the effects of different generator conjectures regarding rival supply responses and transmission prices. If generators anticipate that their increased demand for transmission services will increase transmission prices, then competitive intensity diminishes and energy prices rise. In the example here, the effect of this anticipation is to double the price increase that results from oligopolistic (Cournot) competition among generators

  18. Application of Multipoint DC Voltage Control in VSC-MTDC System

    Directory of Open Access Journals (Sweden)

    Yang Xi

    2013-01-01

    Full Text Available The voltage-source-converter- (VSC- based multiterminal VSC-HVDC power transmission system (VSC-MTDC is an ideal approach to connect wind farm with power grid. Analyzing the characteristics of doubly fed induction generators as well as the basic principle and the control strategy of VSC-MTDC, a multiterminal DC voltage control strategy suitable for wind farm connected with VSC-MTDC is proposed. By use of PSCAD/EMTDC, the proposed control strategy is simulated, and simulation results show that using the proposed control strategy the conversion between constant power control mode and constant DC voltage control mode can be automatically implemented; thus the DC voltage stability control and reliable power output of wind farm can be ensured after the fault-caused outage of converter station controlled by constant DC voltage and under other faults. The simulation result shows that the model can fulfill multiterminal power transmission and fast response control.

  19. Commercial information system of Slovak Electricity Transmission System, Plc

    International Nuclear Information System (INIS)

    Laznicka, L.

    2004-01-01

    Commercial Information System (CIS), which main role of is to support the commercial activities of the company, is built up by business department of SEPS, Plc in close co-operation with the supplier company Sfera, Plc. The system entries are data from electricity meters obtained by automatized data acquisition and from bugging sheets, contractual hour diagrams, parameters of transmission system like measuring schemes and formulas for calculation of demand and supply, contractual data resulting from agreements, business conditions, URSO decisions and valid legislative. A part of the system is also support of process of data evaluation like calculation of transmitted energy quantity, calculation of actual output diagrams, comparison of actual and contractual diagrams, calculation of system divergence, calculation of demand divergence, etc. The final price for the drawings of services, which are joined with transmission of the electric power will be determined by the accounting process. In this causality there are automatically made out invoices for access, losses, system charges, system services, short-term and long-term transits, divergences and for cross-border transmission auctions. System also generates various specialized synopses and statistics for the evaluation requirements of important aspects and for parameter observations. Successive liberalisation of the electricity power market, changes in legislative and URSO decisions require CIS to be sufficiently configurable and to adapt flexible on the alternating environs. (author)

  20. Design of wireless data transmission system for spiral CT

    International Nuclear Information System (INIS)

    Wang Jue; Wang Fuquan; Liu Huaili

    2010-01-01

    A new wireless data transmission scheme based on UWB was proposed after studying the structure and character of spiral CT transmission system, the system was designed and validated. Using UWB device as wireless module to realize wireless data transmission. Using FPGA as main controller to meet the requirement of timing control for system module. Using two pieces of SDRAM in pingpang operation to realize large capacity storage mechanism. Using USB 2.0 interface to realize high-speed connection with UWB module. The results show that the transmission speed of the system arrival at 16.87 M bit ps within 3 meters, and the precision is 100%, it can be used for line-array spiral CT. (authors)

  1. Flexible AC transmission systems: the state of the art

    Energy Technology Data Exchange (ETDEWEB)

    Edris, Abdel-Aty [Electric Power Research Inst., Palo Alto, CA (United States). Electric Systems Division

    1994-12-31

    Flexible AC transmission systems (FACTS) is a concept promoting the use of power electronic controllers to enhance the controllability and usable capacity of AC transmission. This paper presents the state of the art of FACTS and the status of the current projects for the application of the FACTS controllers in transmission systems. (author) 8 refs., 8 figs.

  2. Transmission techniques for emergent multicast and broadcast systems

    CERN Document Server

    da Silva, Mario Marques; Dinis, Rui; Souto, Nuno; Silva, Joao Carlos

    2010-01-01

    Describing efficient transmission schemes for broadband wireless systems, Transmission Techniques for Emergent Multicast and Broadcast Systems examines advances in transmission techniques and receiver designs capable of supporting the emergent wireless needs for multimedia broadcast and multicast service (MBMS) requirements. It summarizes the research and development taking place in wireless communications for multimedia MBMS and addresses the means to improved spectral efficiency to allow for increased user bit rate, as well as increased capacity of the digital cellular radio network.The text

  3. Data transmission system with encryption by chaotic sequences

    Directory of Open Access Journals (Sweden)

    Politans’kyy R. L.

    2014-06-01

    Full Text Available Protection of transferable information in the telecommunication systems is possible by its imposition of coding sequence on a plaintext. Encryption of pseudorandom sequences can be performed by using generation algorithms which are implemented on the basis of the phenomenon of dynamical chaos, which is sensitive to changes in the initial conditions. One of the major problems encountered in the construction of secure communication systems is to provide synchronization between the receiving and transmitting parties of communication systems. Improvement of methods of hidden data transfer based on the systems with chaotic synchronization is the important task of research in the field of information and telecommunication systems based on chaos. This article shows an implementation of a data transmission system, encrypted by sequences, generated on the basis of one-dimensional discrete chaotic maps with ensuring synchronization of the transmitting and receiving sides of the system. In this system realization of synchronization is offered by a transmission through certain time domains of current value of xn generated by a logistic reflection. Xn transmission period depends on computer speed and distance between subscribers of the system. Its value is determined by transmitting a test message before the session. Infallible reception of test message indicates the optimal choice of a transmission period of the current value of xn. Selection period is done at the program level. For the construction of communication network modern software was used, in particular programming language Delphi 7.0. The work of the system is shown on the example of information transmission between the users of the system. The system operates in real time full duplex mode at any hardware implementation of Internet access. It is enough for the users of the system to specify IP address only.

  4. EHV/HV Underground Cable Systems for Power Transmission

    DEFF Research Database (Denmark)

    Bak, Claus Leth

    of the transmission system must be re‐thought in order to accommodate the transmission needs for the future. New lines have to be constructed. Transmission lines are usually laid out as overhead lines, which are large structures, i.e. a 400 kV power pylon is 50 meters high. According to public opinion, such power...

  5. Subsynchronous Oscillation Problem Research in the UHVDC System of a Regional Power Grid in China

    Directory of Open Access Journals (Sweden)

    Qu Ying

    2016-01-01

    Full Text Available Along with the grid structure being more and more complex and the rapid development of the HVDC system, studying the subsynchronous oscillation (SSO problem on HVDC system has more engineering practice significance. The paper studies subsynchronous oscillations problem of generators near the ±800kV UHVDC converter station, and analyzes the subsynchronous oscillation possibilities through PSCAD/EMTDC simulation. At last, though the researched UHVDC thermal plants have none SSO risk but it needs other measures to make the relevant generators return on normal operation.

  6. Model, Characterization, and Analysis of Steady-State Security Region in AC/DC Power System with a Large Amount of Renewable Energy

    Directory of Open Access Journals (Sweden)

    Zhong Chen

    2017-08-01

    Full Text Available A conventional steady-state power flow security check only implements point-by-point assessment, which cannot provide a security margin for system operation. The concept of a steady-state security region is proposed to effectively tackle this problem. Considering that the commissioning of the increasing number of HVDC (High Voltage Direct Current and the fluctuation of renewable energy have significantly affected the operation and control of a conventional AC system, the definition of the steady-state security region of the AC/DC power system is proposed in this paper based on the AC/DC power flow calculation model including LCC/VSC (Line Commutated Converter/Voltage Sourced Converter-HVDC transmission and various AC/DC constraints, and hence the application of the security region is extended. In order to ensure that the proposed security region can accurately provide global security information of the power system under the fluctuations of renewable energy, this paper presents four methods (i.e., a screening method of effective boundary surfaces, a fitting method of boundary surfaces, a safety judging method, and a calculation method of distances and corrected distance between the steady-state operating point and the effective boundary surfaces based on the relation analysis between the steady-state security region geometry and constraints. Also, the physical meaning and probability analysis of the corrected distance are presented. Finally, a case study is demonstrated to test the feasibility of the proposed methods.

  7. Design of data transmission for a portable DAQ system

    International Nuclear Information System (INIS)

    Zhou Wenxiong; Nan Gangyang; Zhang Jianchuan; Wang Yanyu

    2014-01-01

    Field Programmable Gate Array (FPGA), combined with ARM (Advanced RISC Machines) is increasingly employed in the portable data acquisition (DAQ) system for nuclear experiments to reduce the system volume and achieve powerful and multifunctional capacity. High-speed data transmission between FPGA and ARM is one of the most challenging issues for system implementation. In this paper, we propose a method to realize the high-speed data transmission by using the FPGA to acquire massive data from FEE (Front-end electronics) and send it to the ARM whilst the ARM to transmit the data to the remote computer through the TCP/IP protocol for later process. This paper mainly introduces the interface design of the high-speed transmission method between the FPGA and the ARM, the transmission logic of the FPGA, and the program design of the ARM. The theoretical research shows that the maximal transmission speed between the FPGA and the ARM through this way can reach 50 MB/s. In a realistic nuclear physics experiment, this portable DAQ system achieved 2.2 MB/s data acquisition speed. (authors)

  8. Dynamic Voltage Stability Studies using a Modified IEEE 30-Bus System

    Directory of Open Access Journals (Sweden)

    Oluwafemi Emmanuel Oni

    2016-09-01

    Full Text Available Power System stability is an essential study in the planning and operation of an efficient, economic, reliable and secure electric power system because it encompasses all the facet of power systems operations, from planning, to conceptual design stages of the project as well as during the systems operating life span. This paper presents different scenario of power system stability studies on a modified IEEE 30-bus system which is subjected to different faults conditions. A scenario whereby the longest high voltage alternating current (HVAC line is replaced with a high voltage direct current (HVDC line was implemented. The results obtained show that the HVDC line enhances system stability more compared to the contemporary HVAC line. Dynamic analysis using RMS simulation tool was used on DigSILENT PowerFactory.

  9. 2015 Plan. Project 5: transmission systems of electric power

    International Nuclear Information System (INIS)

    1992-12-01

    The planning aspects of transmission system expansion in Brazil are described, mentioning the evolution at long date of the transmission system, emphasizing the qualitative and strategic aspects. The engineering aspects and the technological development are also presented. (C.G.C.)

  10. Proceedings of the 2008 CIGRE Canada conference on power systems : technology and innovation for the Canadian power grids of the future

    International Nuclear Information System (INIS)

    2008-01-01

    The Conseil International des Grands Reseaux Electriques (CIGRE) promotes technical, economic and environmental developments in electricity transmission and generation. CIGRE Canada is one of 53 national committees of CIGRE. This conference showcased Canadian contributions to the electric power industry and how technology and innovation in the future will influence North American power grids. It provided a forum to discuss technological developments in the electric power industry and present products and services for electrical power systems. Issues concerning the interconnection of non traditional energy sources to the power systems were also discussed along with recent research initiatives related to renewable energy source development. The sessions of the conference were entitled: wind reliability and forecasting; substation automation and communication; human resources and long range planning; power system protection and control; distributed generation; electric vehicles and renewable energy; HVDC and facts; modeling and simulation; markets; overhead transmission lines; and new sensor and de-icing technologies and data management systems. All 68 presentations featured at this conference have been catalogued separately for inclusion in this database. refs., tabs., figs

  11. Research on Travel Control System of Hydrostatic Transmission Chassis

    Directory of Open Access Journals (Sweden)

    Zhao Liang

    2017-01-01

    Full Text Available Aiming at the control problem of driving system of hydrostatic transmission chassis, the composition of the control system of hydrostatic transmission chassis is introduced and the control method of dual engine is solved. According to the number of driving axles in driving process, The external characteristic curve of the engine controls the variable hydraulic pump by one parameter, controls the rotational speed of the variable hydraulic motor according to the change of the vehicle speed, and introduces the control flow of the brake system. It provides a reference for the design of driving control system of multi-axis hydrostatic transmission chassis.

  12. Strategic Generation with Conjectured Transmission Price Responses in a Mixed Transmission Pricing System. Part 1. Formulation

    International Nuclear Information System (INIS)

    Hobbs, B.F.; Rijkers, F.A.M.

    2004-05-01

    The conjectured supply function (CSF) model calculates an oligopolistic equilibrium among competing generating companies (GenCos), presuming that GenCos anticipate that rival firms will react to price increases by expanding their sales at an assumed rate. The CSF model is generalized here to include each generator's conjectures concerning how the price of transmission services (point-to-point service and constrained interfaces) will be affected by the amount of those services that the generator demands. This generalization reflects the market reality that large producers will anticipate that they can favorably affect transmission prices by their actions. The model simulates oligopolistic competition among generators while simultaneously representing a mixed transmission pricing system. This mixed system includes fixed transmission tariffs, congestion-based pricing of physical transmission constraints (represented as a linearized dc load flow), and auctions of interface capacity in a path-based pricing system. Pricing inefficiencies, such as export fees and no credit for counterflows, can be simulated. The model is formulated as a linear mixed complementarity problem, which enables very large market models to be solved. In the second paper of this two-paper series, the capabilities of the model are illustrated with an application to northwest Europe, where transmission pricing is based on such a mixture of approaches

  13. AEP's selection of GE Energy's variable frequency transformer (VFT) for their grid interconnection project between the United States and Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Spurlock, M.; O' Keefe, R. [American Electric Power, Gahanna, OH (United States); Kidd, D. [American Electric Power, Tulsa, OK (United States); Larsen, E. [GE Energy, Schenectady, NY (United States); Roedel, J. [GE Energy, Denver, CO (United States); Bodo, R. [GE Energy, Carrolton, TX (United States); Marken, P. [GE Energy, Columbia City, IN (United States)

    2006-07-01

    Variable frequency transformers (VFTs) are controllable, bi-directional transmission devices capable of allowing power transfer between asynchronous networks. The VFT uses a rotary transformer with 3-phase windings on both the rotor and the stator. A motor and drive system is also used to manipulate the rotational position of the rotor in order to control the magnitude and direction of the power flow. The VFT was recently selected by American Electric Power (AEP) for its new asynchronous transmission link between the United States and Mexico. This paper provided details of the feasibility studies conducted to select the technology. Three categories of asynchronous interconnection devices were evaluated: (1) a VFT; (2) a voltage source converter; and (3) a conventional high voltage direct current (HVDC) back-to-back system. Stability performance system studies were conducted for all options. The overall reliability benefits of the options were reviewed, as well as their ability to meet steady-state system requirements. Dynamic models were used to conduct the comparative evaluation. Results of the feasibility study indicated that both the VFT and the voltage source converter performed better than the HVDC system. However, the VFT was more stable than the voltage source converter. 5 refs., 3 figs.

  14. Optimum transmission system expansion offshore considering renewable energy sources

    NARCIS (Netherlands)

    Torbaghan, Shahab S.; Gibescu, Madeleine

    2017-01-01

    This chapter provides an overview of transmission expansion planning (TEP) methods and their practical application. First, it discusses the strategic importance of the transmission system. Next, it describes the reasons why TEP remains a challenge for systems with a large share of renewable energy.

  15. Security of the data transmission in the industrial control system

    Directory of Open Access Journals (Sweden)

    Marcin Bednarek

    2015-12-01

    Full Text Available The theme of this paper is to present the data transmission security system between the stations of the industrial control system. The possible options for secure communications between process stations, as well as between process and operator station are described. Transmission security mechanism is based on algorithms for symmetric and asymmetric encryption. The authentication process uses a software token algorithm and a one-way hash function. The algorithm for establishing a secured connection between the stations, including the authentication process and encryption of data transmission is given. The process of securing the transmission consists of 4 sub-processes: (I authentication; (II asymmetric, public keys transmission; (III symmetric key transmission; (IV data transmission. The presented process of securing the transmission was realized in the industrial controller and emulator. For this purpose, programming languages in accordance with EN 61131 were used. The functions were implemented as user function blocks. This allows us to include a mixed code in the structure of the block (both: ST and FBD. Available function categories: support of the asymmetric encryption; asymmetric encryption utility functions; support of the symmetric encryption; symmetric encryption utility functions; support of the hash value calculations; utility functions of conversion.[b]Keywords[/b]: transmission security, encryption, authentication, industrial control system

  16. Radio transmission system for industrial area

    International Nuclear Information System (INIS)

    Iliescu, M.; Culcer, M.; Curuia, M.; Anghel, N.M.; Stefanescu, I.

    2003-01-01

    The paper deals with a data transmission system operating in a large, noisy industrial area. The radio transmission system permits data and commands communication between the local units of collecting data and a central monitoring and/or command station ( dispatch). The communication support are radio waves in the range 450 MHz. The transducers are of transmitter type, with 4-20 mA output signal, providing information about environmental and/or work parameters. Data are primarily acquisitioned in a data logger with microcontroller, then transmitted via a FSK radio modem and a radio station to the dispatch. Data logger can also be connected in a network. The dispatch personal computer receives and processes data and transmits commands. The system functioning is supervised by a communication software in MCS - 51 assembler and an application software in Visual C ++ . (author)

  17. Efficiency Analyses of a DC Residential Power Distribution System for the Modern Home

    Directory of Open Access Journals (Sweden)

    GELANI, H. E.

    2015-02-01

    Full Text Available The electric power system started as DC back in the nineteenth century. However, the DC paradigm was soon ousted by AC due to inability of DC to change its voltage level. Now, after many years, with the development of power electronic converters capable of stepping-up and down DC voltage and converting it to-and-from AC, DC appears to be challenging AC and attempting a comeback. We now have DC power generation by solar cells, fuel cells and wind farms, DC power transmission in the form of HVDC (High Voltage DC transmission, DC power utilization by various modern electronic loads and DC power distribution that maybe regarded as still in research phase. This paper is an attempt to investigate feasibility of DC in the distribution portion of electrical power system. Specifically, the efficiency of a DC distribution system for residential localities is determined while keeping in view the concept of daily load variation. The aim is to bring out a more practical value of system efficiency as the efficiencies of DC/DC converters making up the system vary with load variation. This paper presents the modeling and simulation of a DC distribution system and efficiency results for various scenarios are presented.

  18. Progress and monitoring system on compression and transmission technologies of dynamic image

    International Nuclear Information System (INIS)

    Kobayashi, Hiroyuki; Saijo, Nobuyuki; Nakajo, Ken

    2001-01-01

    The Toshiba Corporation developed a real-time dynamic image transmission matched with quality of transmission circuit by using MPEG-4 which was recent international standard system for the dynamic image coding system. Concretely, this system made possible on real-time dynamic image transmission even at transmission on wireless circuit such as portable telephone, PHS, wireless LAN, and so on, at viewpoint of the mobile communication. And, by using the wireless circuit, it could be built without any limit of transmission cable, to realize its layout-free establishment. In addition, this system uses only image for communication without using voice, and some devices were carried out to upgrade image and frame speed as possible. Here were described on outlines of transmission system and principle of detection MPEG-4, and function and application of monitoring system using this system. (G.K.)

  19. Scenario calculations for the 2012 grid development plan. Overdimensioned HVDC transmission lines; Szenarienrechnungen zum Netzentwicklungsplan (NEP) 2012. HGUe-Leitungen ueberdimensioniert

    Energy Technology Data Exchange (ETDEWEB)

    Oei, Pao-Yu; Sander, Aram; Hankel, Lisa; Laurisch, Lilian; Lorenz, Casimir [Technische Univ. Berlin (Germany); Schroeder, Andreas [Deutsches Institut fuer Wirtschaftsforschung, Berlin (Germany)

    2012-09-15

    The grid development plan presented in June 2012 by the German Federal Network Agency envisages a large number of new AC and DC transmission lines for Germany. The purpose of these transmission lines is to facilitate the point-to-point transport of electricity produced from renewable resources to load centres. The authors present a model-assisted analysis of the impact of these transmission lines on the structure of electricity production. They also investigate to what extent an increase in storage capacity and the steering of demand can serve as alternatives to grid expansion.

  20. Realistic modeling of radiation transmission inspection systems

    International Nuclear Information System (INIS)

    Sale, K.E.

    1993-01-01

    We have applied Monte Carlo particle transport methods to assess a proposed neutron transmission inspection system for checked luggage. The geometry of the system and the time, energy and angle dependence of the source have been modeled in detail. A pulsed deuteron beam incident on a thick Be target generates a neutron pulse with a very broad energy spectrum which is detected after passage through the luggage item by a plastic scintillator detector operating in current mode (as opposed to pulse counting mode). The neutron transmission as a function of time information is used to infer the densities of hydrogen, carbon, oxygen and nitrogen in the volume sampled. The measured elemental densities can be compared to signatures for explosives or other contraband. By using such computational modeling it is possible to optimize many aspects of the design of an inspection system without costly and time consuming prototyping experiments or to determine that a proposed scheme will not work. The methods applied here can be used to evaluate neutron or photon schemes based on transmission, scattering or reaction techniques

  1. Marginal cost calculation of energy production in hydro thermoelectric systems considering the transmission system

    International Nuclear Information System (INIS)

    Pereira, M.V.F.; Gorenstin, B.G.; Alvarenga Filho, S.

    1989-01-01

    The alternatives for calculation of energy marginal cost in hydroelectric systems, considering the transmission one, was analysed, including fundamental concepts; generation/transmission systems, represented by linear power flow model; production marginal costs in hydrothermal systems and computation aspects. (C.G.C.). 11 refs, 5 figs

  2. System of failures diagnosis for energy transmission systems, using Petri nets

    International Nuclear Information System (INIS)

    Zapata, German; Grisales, John Faber; Gomez, Juan Camilo; Quintero Henao, Luis Fernando

    2005-01-01

    An expert system of second generation was used integrating the inverse Petri nets (RPN) and the systems based on rules (rule-based system) for the accomplishment of a program in Visual Basic that helps in the obtaining of an opportune and fast analysis of transmission of energy at the time of happening a fault in anymore of its components (line or bus). The program is proven in a portion of system IEEE -118 standard bus test system, in which two extracted cases of literature are developed and are the obtained results. Finally tests realized with the method developed in the laboratory of machines of the national university of Colombia, Medellin campus, simulating a system of transmission with two lines and two buses

  3. Automated transmission system operation and management : meeting stakeholder information needs

    Energy Technology Data Exchange (ETDEWEB)

    Peelo, D.F.; Toom, P.O. [British Columbia Hydro, Vancouver, BC (Canada)

    1998-12-01

    Information monitoring is considered to be the fundamental basis for moving beyond substation automation and into automated transmission system operation and management. Information monitoring was defined as the acquisition of data and processing the data into decision making. Advances in digital technology and cheaper, more powerful computing capability has made it possible to capture all transmission stakeholder needs in a shared and automated operation and management system. Recognizing that the key to success in the development of transmission systems is automation, BC Hydro has initiated a long-term research and development project to develop the structure and detail of transmission system automation. The involvement of partners, be they utility or equipment suppliers, is essential in order to deal with protocol and similar issues. 3 refs., 1 tab., 3 figs.

  4. Natural Characteristics of The Herringbone Gear Transmission System

    Science.gov (United States)

    Zhou, Jianxing; Sun, Wenlei; Cao, Li

    2018-03-01

    According to the structure characteristics of herringbone gear transmission, a more realistic dynamic model of the transmission system is built in consideration of the inner excitation, herringbone gears axial positioning and sliding bearing etc. The natural frequencies of the system are calculated, and the vibration mode is divided into symmetric vibration modes and asymmetric vibration modes. The time history of system dynamic force is obtained by solving the dynamic model. The effects of the connection stiffness of left and right sides of herringbone gears and axial support stiffness on natural characteristics are discussed.

  5. [Review of wireless energy transmission system for total artificial heart].

    Science.gov (United States)

    Zhang, Chi; Yang, Ming

    2009-11-01

    This paper sums up the fundamental structure of wireless energy transmission system for total artificial heart, and compares the key parameters and performance of some representative systems. After that, it is discussed that the future development trend of wireless energy transmission system for total artificial heart.

  6. Distance Protection of Cross-Bonded Transmission Cable-Systems

    DEFF Research Database (Denmark)

    Bak, Claus Leth; F. Jensen, Christian

    2014-01-01

    In this paper the problems of protecting a cross-bonded cable system using distance protection are analysed. The combination of the desire to expand the high voltage transmission grid and the public's opinion towards new installations of overhead lines (OHL), more and more transmission cable syst...

  7. Development of high speed and reliable data transmission system for industrial CT

    International Nuclear Information System (INIS)

    Gao Fuqiang; Dong Yanli; Liu Guohua

    2010-01-01

    In order to meet the requirements of large capacity,high speed and high reliability of data transmission for industrial CT, a data transmission system based on USB 2.0 was designed. In the process of data transmission, FPGA was the main controller, and USB 2.0 CY7C68013A worked in slave FIFO mode. The system sent the data got from data acquisition system to host computer for image reconstruction. The testing results show that the transmission rate can reach 33 MB/s and the precision is 100%. The system satisfies the requirements of data transmission for industrial CT. (authors)

  8. Stokes Space in Direct-Detection Data Transmission Systems

    DEFF Research Database (Denmark)

    Estaran Tolosa, Jose Manuel; Lu, Xiaofeng; Zibar, Darko

    2015-01-01

    Stokes-based processing permits complete and phase-insensitive characterization of the field’s SOP, readily unlocking polarization diversity in transmission systems where DD is desired. We present an overview on Stokes notions and most recent achievements in this context.......Stokes-based processing permits complete and phase-insensitive characterization of the field’s SOP, readily unlocking polarization diversity in transmission systems where DD is desired. We present an overview on Stokes notions and most recent achievements in this context....

  9. Transmission Reinforcements in the Central American Regional Power System

    Energy Technology Data Exchange (ETDEWEB)

    Elizondo, Marcelo A.; Vallem, Mallikarjuna R.; Samaan, Nader A.; Makarov, Yuri V.; Vyakaranam, Bharat; Nguyen, Tony B.; Munoz, Christian; Herrera, Ricardo; Midence, Diego; Shpitsberg, Anna

    2016-07-25

    The Central American regional interconnected power system (SER) connects the countries members of the Central American regional electricity market (MER): Guatemala, El Salvador, Honduras, Nicaragua, Costa Rica, and Panama. The SER was a result of a long term regional effort, and was initially conceived to transfer 300 MW between countries. However, the current transfer limits between countries range from 70 MW to 300 MW. Regional entities, like CRIE (Regional Commission of Electrical Interconnection), EOR (Central American Regional System Operator), and CDMER (Board of Directors of the Central American Market) are working on coordinating the national transmission expansion plans with regional transmission planning efforts. This paper presents experience in Central America region to recommend transmission reinforcements to achieve 300 MW transfer capacity between any pair of member countries of the Central American regional electricity market (MER). This paper also provides a methodology for technical analysis and for coordination among the regional and national entities. This methodology is unique for transmission systems of these characteristics.

  10. Barriers and solutions for AC low voltage fault ride-through on multi-terminal HVDC grids

    Energy Technology Data Exchange (ETDEWEB)

    Silva, B.; Moreira, C.L.; Leite, H.; Pecas Lopes, J.A. [Porto Univ. (Portugal). Dept. de Engenharia Electrotecnica e de Computadores (DEEC); Tecnologia e Ciencia, Porto (Portugal). Inst. de Engenharia de Sistemas e Computadores (INESCTEC)

    2012-07-01

    This work analyzes the multi-terminal DC grids dynamics under AC mainland grid fault events envisioning to assess the feasibility of fault ride-through provision. The major bottleneck related with the operation under AC fault consists on the DC side power imbalance that takes place due to the HVDC converter current limits and consequent incapability of delivering all the generated power to the grid. It was also verified that the power imbalance leads to a DC overvoltage occurrence. The mechanism of including chopper devices at the onshore converters DC terminals has been studied as a mean of power equilibrium promotion. Simulations comparing the both cases were performed and the comparison and the effectiveness of the adopted approach are also presented. (orig.)

  11. [Study on a wireless energy transmission system for the noninvasive examination micro system inside alimentary tracts].

    Science.gov (United States)

    He, Xiu; Yan, Guo-Zheng; Wang, Fu-Min

    2008-01-01

    A wireless energy transmission system for the MEMS system inside alimentary tracts is reported here in the paper. It consists of an automatic frequency tracking circuit of phase lock loop and phase shift PWM control circuit. Experimental results show that the energy transmission system is capable of automatic frequency-tracking and transmission power-adjusting and has stable received energy.

  12. Research on Image Transmission System Based on 3G Communication Platform

    Directory of Open Access Journals (Sweden)

    Jingfeng Zang

    2014-07-01

    Full Text Available A wireless image real-time transmission system is designed by using 3G wireless communication platform and ARM + DSP embedded system. In the environment of 3G networks, the embedded equipment has realized the functions of coding, acquisition, network transmission, decoding and playing. It is realized for real-time video of intelligent control and video compression, storage and playback in the 3G embedded image transmission system. It is especially suitable for remote location or irregular cable network transmission conditions applications. It is shown that in the 3G network video files are transferred quickly. The real-time transmission of H.264 video is broadcasted smoothly, and color distortion is less. The server can control client by remote intelligent units.

  13. A review on fault classification methodologies in power transmission systems: Part-II

    Directory of Open Access Journals (Sweden)

    Avagaddi Prasad

    2018-05-01

    Full Text Available The countless extent of power systems and applications requires the improvement in suitable techniques for the fault classification in power transmission systems, to increase the efficiency of the systems and to avoid major damages. For this purpose, the technical literature proposes a large number of methods. The paper analyzes the technical literature, summarizing the most important methods that can be applied to fault classification methodologies in power transmission systems.The part 2 of the article is named “A review on fault classification methodologies in power transmission systems”. In this part 2 we discussed the advanced technologies developed by various researchers for fault classification in power transmission systems. Keywords: Transmission line protection, Protective relaying, Soft computing techniques

  14. Force transmissibility versus displacement transmissibility

    Science.gov (United States)

    Lage, Y. E.; Neves, M. M.; Maia, N. M. M.; Tcherniak, D.

    2014-10-01

    It is well-known that when a single-degree-of-freedom (sdof) system is excited by a continuous motion of the foundation, the force transmissibility, relating the force transmitted to the foundation to the applied force, equals the displacement transmissibility. Recent developments in the generalization of the transmissibility to multiple-degree-of-freedom (mdof) systems have shown that similar simple and direct relations between both types of transmissibility do not appear naturally from the definitions, as happens in the sdof case. In this paper, the authors present their studies on the conditions under which it is possible to establish a relation between force transmissibility and displacement transmissibility for mdof systems. As far as the authors are aware, such a relation is not currently found in the literature, which is justified by being based on recent developments in the transmissibility concept for mdof systems. Indeed, it does not appear naturally, but the authors observed that the needed link is present when the displacement transmissibility is obtained between the same coordinates where the applied and reaction forces are considered in the force transmissibility case; this implies that the boundary conditions are not exactly the same and instead follow some rules. This work presents a formal derivation of the explicit relation between the force and displacement transmissibilities for mdof systems, and discusses its potential and limitations. The authors show that it is possible to obtain the displacement transmissibility from measured forces, and the force transmissibility from measured displacements, opening new perspectives, for example, in the identification of applied or transmitted forces. With this novel relation, it becomes possible, for example, to estimate the force transmissibility matrix with the structure off its supports, in free boundary conditions, and without measuring the forces. As far as force identification is concerned, this

  15. Control and simulation of fault and change effect in a back to back system of high voltage direct current network

    International Nuclear Information System (INIS)

    Mohsen, Kalantar; Mehdi, Rashidi; Mehdi, Rashidi; Tabatabaei, Naser M.

    2005-01-01

    Full text : The primary knowledge of human being from electrical energy was in the form of statistic electricity and the first transmission line was DC. But because of primary problems in transmitting electrical power in DC form with average and low voltage levels and because of the higher efficiency of AC machines in comparison with DC machines and presence of AC transistors in different capacitance, have caused the electrical power to be transmitted in AC form. But with the avancement of electrical engineering technology in the 20th century, the transition systems were used in HVDC form, and from that time the HDVC technology passed its improvement process so fast. In this paper in addition to discussing the advantage of HDVC systems and back to back instruction, the fault and change effect in a back to back system is discussed

  16. Experimental investigation of alternative transmission functions: Quantitative evidence for the importance of nonlinear transmission dynamics in host-parasite systems.

    Science.gov (United States)

    Orlofske, Sarah A; Flaxman, Samuel M; Joseph, Maxwell B; Fenton, Andy; Melbourne, Brett A; Johnson, Pieter T J

    2018-05-01

    Understanding pathogen transmission is crucial for predicting and managing disease. Nonetheless, experimental comparisons of alternative functional forms of transmission remain rare, and those experiments that are conducted are often not designed to test the full range of possible forms. To differentiate among 10 candidate transmission functions, we used a novel experimental design in which we independently varied four factors-duration of exposure, numbers of parasites, numbers of hosts and parasite density-in laboratory infection experiments. We used interactions between amphibian hosts and trematode parasites as a model system and all candidate models incorporated parasite depletion. An additional manipulation involving anaesthesia addressed the effects of host behaviour on transmission form. Across all experiments, nonlinear transmission forms involving either a power law or a negative binomial function were the best-fitting models and consistently outperformed the linear density-dependent and density-independent functions. By testing previously published data for two other host-macroparasite systems, we also found support for the same nonlinear transmission forms. Although manipulations of parasite density are common in transmission studies, the comprehensive set of variables tested in our experiments revealed that variation in density alone was least likely to differentiate among competing transmission functions. Across host-pathogen systems, nonlinear functions may often more accurately represent transmission dynamics and thus provide more realistic predictions for infection. © 2017 The Authors. Journal of Animal Ecology published by John Wiley & Sons Ltd on behalf of British Ecological Society.

  17. Towards an optimal transmission system

    International Nuclear Information System (INIS)

    Calviou, M.

    2005-01-01

    This presentation provided background on National Grid USA and discussed transmission investment in the United States (US) and United Kingdom. It also discussed barriers to transmission investments and improvements, thoughts on solutions and a long-term vision. The presentation identified that transmission investment should follow from clear reliability rules designed to promote better operation and management; investment does not necessarily mean new rights-of-way; and transmission investment should target benefits to customers. It was stated that US transmission investment levels have decreased. A comparison between US and UK transmission investment was presented along with a chart of increasing US congestion costs. Barriers to investment in US transmission include vertical integration; misperception of transmission as a market product; federal and state jurisdiction issues; fragmentation in transmission ownership and operation; rate cap based plans that impact transmission; lack of clarity in cost allocation; and the site selection process. Possible solutions include policy and incentives, promoting independence and resolving structural issues. tabs., figs

  18. European standards applied by Gas Transmission System Operator

    International Nuclear Information System (INIS)

    Witek, M.; Kuchta, K.; Oleszkiewicz, J.; Teperek, T.

    2005-01-01

    The lecture described actual state of implementation of European standards concerning transmission of natural gas and underlined their importance for proper performance of Transmission System Operator (TSO). European standards implemented to Polish Standards as PN-EN, necessary for TSO, related to design, construction and operation of high pressure gas network were also described. The lecture underlined as well the impact of standards application on preparation process of national regulations. They obligate TSO to create the technical conditions that ensure safety of gas transmission network functioning as well as environmental and surroundings safety. (authors)

  19. Alternative electrical transmission systems and their environmental impact

    Energy Technology Data Exchange (ETDEWEB)

    Schiefelbein, G.F.

    1977-08-01

    A general description is provided of electrical transmission systems as an aid in determining their environmental impacts. Alternating current, direct current, overhead systems, underground systems, and water crossings are treated. The cost, performance, reliability, safety, and environmental impact of these systems are compared.

  20. Analysis and evaluation of hybrid scooter transmission systems

    Energy Technology Data Exchange (ETDEWEB)

    Sheu, Kuen-Bao [Department of Vehicle Engineering, National Formosa University, 64 Wunhua Road, Huwei, Yuenlin 63208 (China)

    2007-12-15

    This paper presents a new design concept of transmissions for the hybrid scooters. These transmissions consist of a one-degree-of-freedom planetary gear train and a two-degree-of-freedom planetary gear train to from a split power system and to combine the power of two power sources, a gasoline engine and an electric motor. In order to maximize the performance and reduce emissions, the transmissions can provide a hybrid scooter to run five operating modes: electric motor mode; engine mode; engine/charging mode; power mode, and regenerative braking mode. The main advantages of the transmissions proposed in this paper include the use of only one electric motor/generator, need not use clutch/brake for the shift of the operating modes, and high efficiency. The kinematics, power flow, and mechanical efficiency analyzes are performed; and according to these results, the evaluation of transmission power performances are accomplished. (author)

  1. 75 FR 62476 - Ultra-Wideband Transmission Systems

    Science.gov (United States)

    2010-10-12

    ... would be obtained from measurements taken with the system operating in its normal operating mode. At the... with the transmitter operating continuously at a fundamental transmission frequency. 9. Subsequent to... systems, measured in their normal operating modes, is less than that of a UWB transmitter employing...

  2. Analysis of disabled HVDC transformer

    International Nuclear Information System (INIS)

    Hestad, Oeystein; Linhjell, Dag

    2006-02-01

    An examination of three windings from a disabled Hvdc transformer. The windings were dismantled at the company ABB Drammen. Test were taken and brought to Trondheim for further analysis. Of the three windings, two were strongly contaminated by copper sulphite while the last one recently had been replaced after a previous breakdown and only showed small signs of copper sulphite contamination. The following analyses have been conducted: visual observation of copper sulphite contamination on the conductors/paper, electron microscope analysis of the surface of selected bits of paper, measuring of the conducing ability by means of examining paper samples of varying degrees of contamination, and GC-AED and combustion analysis of the disabled transformer's oil and the oil from a 'healthy' transformer. The visual examination showed a strong contamination of the upper (hot) parts of the windings as well as two areas just below the middle of the windings. The contamination was especially strong under the buttons and between the conductors where the oil flow is reduced compared to the areas where the paper is in direct contact with free flow of oil. The degree of contamination on the paper proved to be directly correlated to the electric conducing ability through the paper and the amount of copper and sulphur measured in the electron microscope analysis. Copper sulphite grows through the paper, but the 'contamination' between the layers of paper is fastest through the gaps. When copper sulphite grows through the paper via the gaps, a current causes carbonisation of the paper in the area, and finally a short circuit between the windings. A comparison between the two oil samples that were analyzed by GC-AED and combustion analysis showed that the two oils probably were similar to begin with. The total amount of sulphur components in the oil from the disabled transformer has thus increased during the lifetime of the transformer. The new sulphur components have probably been

  3. Feasibility study of wireless power transmission systems

    Science.gov (United States)

    Robinson, W. J., Jr.

    1968-01-01

    Wireless microwave or laser energy transfers power from a manned earth-orbiting central station to unmanned astronomical substations. More efficient systems are required for the microwave power transmission.

  4. 40 Gb/s optical transmission systems

    DEFF Research Database (Denmark)

    Buxens Azcoaga, Alvaro Juan; Nielsen, Steen Krogh

    2003-01-01

    ; chromatic dispersion, Polarization Mode Dispersion (PMD), Self Phase Modulation (SPM) and linear or non-linear crosstalk among others. Regarding chromatic dispersion, sufficient evidence is presented for the need in 40 Gb/s systems of either modulation formats that allow for higher tolerance than....... Using a 9 ps pulsed RZ Tx, transmission is achieved over a 400 km link consisting of 5 spans of 80 km standard-SMF with a Quality (Q) factor of 17.7 dB, while for NRZ it is reduced to 15 dB. In another experimental verification over 40 km spans of standard-SMF, we could achieve transmission over 6 spans...

  5. A high-speed transmission method for large-scale marine seismic prospecting systems

    International Nuclear Information System (INIS)

    KeZhu, Song; Ping, Cao; JunFeng, Yang; FuMing, Ruan

    2012-01-01

    A marine seismic prospecting system is a kind of data acquisition and transmission system with large-scale coverage and synchronous multi-node acquisition. In this kind of system, data transmission is a fundamental and difficult technique. In this paper, a high-speed data-transmission method is proposed, its implications and limitations are discussed, and conclusions are drawn. The method we propose has obvious advantages over traditional techniques with respect to long-distance operation, high speed, and real-time transmission. A marine seismic system with four streamers, each 6000 m long and capable of supporting up to 1920 channels, was designed and built based on this method. The effective transmission baud rate of this system was found to reach up to 240 Mbps, while the minimum sampling interval time was as short as 0.25 ms. This system was found to achieve a good synchronization: 83 ns. Laboratory and in situ experiments showed that this marine-prospecting system could work correctly and robustly, which verifies the feasibility and validity of the method proposed in this paper. In addition to the marine seismic applications, this method can also be used in land seismic applications and certain other transmission applications such as environmental or engineering monitoring systems. (paper)

  6. A high-speed transmission method for large-scale marine seismic prospecting systems

    Science.gov (United States)

    KeZhu, Song; Ping, Cao; JunFeng, Yang; FuMing, Ruan

    2012-12-01

    A marine seismic prospecting system is a kind of data acquisition and transmission system with large-scale coverage and synchronous multi-node acquisition. In this kind of system, data transmission is a fundamental and difficult technique. In this paper, a high-speed data-transmission method is proposed, its implications and limitations are discussed, and conclusions are drawn. The method we propose has obvious advantages over traditional techniques with respect to long-distance operation, high speed, and real-time transmission. A marine seismic system with four streamers, each 6000 m long and capable of supporting up to 1920 channels, was designed and built based on this method. The effective transmission baud rate of this system was found to reach up to 240 Mbps, while the minimum sampling interval time was as short as 0.25 ms. This system was found to achieve a good synchronization: 83 ns. Laboratory and in situ experiments showed that this marine-prospecting system could work correctly and robustly, which verifies the feasibility and validity of the method proposed in this paper. In addition to the marine seismic applications, this method can also be used in land seismic applications and certain other transmission applications such as environmental or engineering monitoring systems.

  7. A full-duplex CATV/wireless-over-fiber lightwave transmission system.

    Science.gov (United States)

    Li, Chung-Yi; Lu, Hai-Han; Ying, Cheng-Ling; Cheng, Chun-Jen; Lin, Che-Yu; Wan, Zhi-Wei; Chen, Jian-Hua

    2015-04-06

    A full-duplex CATV/wireless-over-fiber lightwave transmission system consisting of one broadband light source (BLS), two optical interleavers (ILs), one intensity modulator, and one phase modulator is proposed and experimentally demonstrated. The downstream light is optically promoted from 10Gbps/25GHz microwave (MW) data signal to 10Gbps/100GHz and 10Gbps/50GHz millimeter-wave (MMW) data signals in fiber-wireless convergence, and intensity-modulated with 50-550 MHz CATV signal. For up-link transmission, the downstream light is phase-remodulated with 10Gbps/25GHz MW data signal in fiber-wireless convergence. Over a 40-km single-mode fiber (SMF) and a 10-m radio frequency (RF) wireless transport, bit error rate (BER), carrier-to-noise ratio (CNR), composite second-order (CSO), and composite triple-beat (CTB) are observed to perform well in such full-duplex CATV/wireless-over-fiber lightwave transmission systems. This full-duplex 100-GHz/50-GHz/25-GHz/550-MHz lightwave transmission system is an attractive alternative. This transmission system not only presents its advancement in the integration of fiber backbone and CATV/wireless feeder networks, but also it provides the advantages of a communication channel for higher data rates and bandwidth.

  8. Benchmarking European Gas Transmission System Operators

    DEFF Research Database (Denmark)

    Agrell, Per J.; Bogetoft, Peter; Trinkner, Urs

    This is the final report for the pan-European efficiency benchmarking of gas transmission system operations commissioned by the Netherlands Authority for Consumers and Markets (ACM), Den Haag, on behalf of the Council of European Energy Regulators (CEER) under the supervision of the authors....

  9. Cryogenic System for a High-Temperature Superconducting Power Transmission Cable

    International Nuclear Information System (INIS)

    Demko, J.A.; Gouge, M.J.; Hughey, R.L.; Lue, J.W.; Martin, R.; Sinha, U.; Stovall, J.P.

    1999-01-01

    High-temperature superconducting (HTS) cable systems for power transmission are under development that will use pressurized liquid nitrogen to provide cooling of the cable and termination hardware. Southwire Company and Oak Ridge National Laboratory have been operating a prototype HTS cable system that contains many of the typical components needed for a commercial power transmission application. It is being used to conduct research in the development of components and systems for eventual commercial deployment. The cryogenic system was built by Air Products and Chemicals, Allentown, Pennsylvania, and can circulate up to 0.35 kg/s of liquid nitrogen at temperatures as low as 67 K at pressures of 1 to 10 bars. Sufficient cooling is provided for testing a 5-m-long HTS transmission cable system that includes the terminations required for room temperature electrical connections. Testing of the 5-m HTS transmission cable has been conducted at the design ac conditions of 1250 A and 7.5 kV line to ground. This paper contains a description of the essential features of the HTS cable cryogenic system and performance results obtained during operation of the system. The salient features of the operation that are important in large commercial HTS cable applications will be discussed

  10. Theoretical analysis of a wind heating conversion and long distance transmission system

    International Nuclear Information System (INIS)

    Cheng, Wen-Long; Han, Bing-Chuan; Nian, Yong-Le; Han, Bing-Bing

    2017-01-01

    Highlights: • A novel long distance wind power heating system was proposed. • Heat losses could be reduced effectively due to latent heat transmission. • Power consumption and cost would drop greatly compared to hot water convey system. • The maximum transmission distance is 10 times that of conventional system. - Abstract: As a clean and renewable energy, wind power gets a rapid growth in recent years. With the increasing proportion of wind power generation, the fluctuation and intermittency of wind energy impedes the safe and stable operation of national power grids, which causes wind curtailment and energy waste, hindering further development of wind power industry in China. To solve this problem, wind heating conversion was proposed. However, long distance transmission between wind fields and residential areas for thermal energy is an urgent issue for wind heating. This paper presents a novel wind heating conversion and long distance transmission system. A simple device was utilized for wind heating conversion in the present system, then thermal energy was transported to heat demand site through latent heat transmission of the working fluids. A model of the novel system was built and thermodynamics analysis showed that maximum transmission distance of the novel system could extended to 240 km, 9.6 times of that of typical hot water transmission system. And the novel system also could cut down the cost by greatly reducing pump work and pipe diameter. In addition, efficiency and circulation ratio was almost unchanged while wind power density increased from 350 W/m 2 to 650 W/m 2 .

  11. FPGA Implementation of Video Transmission System Based on LTE

    Directory of Open Access Journals (Sweden)

    Lu Yan

    2015-01-01

    Full Text Available In order to support high-definition video transmission, an implementation of video transmission system based on Long Term Evolution is designed. This system is developed on Xilinx Virtex-6 FPGA ML605 Evaluation Board. The paper elaborates the features of baseband link designed in Xilinx ISE and protocol stack designed in Xilinx SDK, and introduces the process of setting up hardware and software platform in Xilinx XPS. According to test, this system consumes less hardware resource and is able to transmit bidirectional video clearly and stably.

  12. Transmission techniques for 4G systems

    CERN Document Server

    Da Silva, Mario Marques

    2012-01-01

    Fourth Generation (4G) wireless communication systems support current and emergent multimedia services such as mobile TV, social networks and gaming, high-definition TV, video teleconferencing, and messaging services. These systems feature the All-over-IP concept and boast improved quality of service. Several important R&D activities are currently under way in the field of wireless communications for 4G systems, but the coverage is widespread in the literature. Transmission Techniques for 4G Systems presents a compilation of the latest developments in the field of wireless communications for 4

  13. Medical data transmission system for remote healthcare centres

    International Nuclear Information System (INIS)

    Gonzalez, E A; Cagnolo, F J; Olmos, C E; Centeno, C A; Riva, G G; Zerbini, C A

    2007-01-01

    The main motivation of this project is to improve the healthcare centres equipment and human resources efficiency, enabling those centres for transmission of parameters of medical interest. This system facilitates remote consultation, in particular between specialists and remote healthcare centres. Likewise it contributes to the qualification of professionals. The electrocardiographic (ECG) and electroencephalographic (EEG) signals are acquired, processed and then sent, fulfilling the effective norms, for application in the hospital network of Cordoba Province, which has nodes interconnected by phone line. As innovative aspects we emphasized the low cost of development and maintenance, great versatility and handling simplicity with a modular design for interconnection with diverse data transmission media (Wi-Fi, GPRS, etc.). Successfully experiences were obtained during the acquisition of the signals and transmissions on wired LAN networks. As improvements, we can mention: energy consumption optimization and mobile communication systems usage, in order to offer more autonomy

  14. Research of pneumatic control transmission system for small irradiation samples

    International Nuclear Information System (INIS)

    Bai Zhongxiong; Zhang Haibing; Rong Ru; Zhang Tao

    2008-01-01

    In order to reduce the absorbed dose damage for the operator, pneumatic control has been adopted to realize the rapid transmission of small irradiation samples. On/off of pneumatic circuit and directions for the rapid transmission system are controlled by the electrical control part. The main program initializes the system and detects the location of the manual/automatic change-over switch, and call for the corresponding subprogram to achieve the automatic or manual operation. Automatic subprogram achieves the automatic sample transmission; Manual subprogram completes the deflation, and back and forth movement of the radiation samples. This paper introduces in detail the implementation of the system, in terms of both hardware and software design. (authors)

  15. PROXY-BASED PATCHING STREAM TRANSMISSION STRATEGY IN MOBILE STREAMING MEDIA SYSTEM

    Institute of Scientific and Technical Information of China (English)

    Liao Jianxin; Lei Zhengxiong; Ma Xutao; Zhu Xiaomin

    2006-01-01

    A mobile transmission strategy, PMPatching (Proxy-based Mobile Patching) transmission strategy is proposed, it applies to the proxy-based mobile streaming media system in Wideband Code Division Multiple Access (WCDMA) network. Performance of the whole system can be improved by using patching stream to transmit anterior part of the suffix that had been played back, and by batching all the demands for the suffix arrived in prefix period and patching stream transmission threshold period. Experimental results show that this strategy can efficiently reduce average network transmission cost and number of channels consumed in central streaming media server.

  16. Harmonics in transmission power systems

    DEFF Research Database (Denmark)

    Wiechowski, Wojciech Tomasz

    . The comparison shows that results obtained used both types of the cores are the same, so it is concluded that both cores can be used for harmonic measurements. Low-inductance resistors are introduced in the secondary circuits, in series with the metering and protective relaying. On those resistors, the harmonic......Some time ago, Energinet.dk, the Transmission System Operator of the 150 kV and 400 kV transmission network in Denmark, had experienced operational malfunctions of some of the measuring and protection equipment. Also an overloading of a harmonic filter has been reported, and therefore, a need...... end only so the ground is not used as a return path. A way to reduce the capacitive coupling is to provide shielding. Harmonic currents are measured using the conventional inductive voltage transformers. Both protective and metering cores were compared if they could be used for harmonic measurements...

  17. Multilink DC Transmission for Offshore Wind Power Integration

    DEFF Research Database (Denmark)

    Craciun, Bogdan-Ionut; Silva, Rodrigo Da; Teodorescu, Remus

    2012-01-01

    analysis the Multi Terminal Direct Current (MTDC) operation and focuses on the sharing of active power produced by an offshore Wind Power Plant (WPP). The first objective was to model the system in PSCAD/EMTDC simulation software and then control structure tested under different situations. The second......The High Voltage Direct Current (HVDC) system gains much more flexibility on a basis of multi terminal operation. Having extra converters brings also new ideas in sharing the active power and one of the solutions is the use of virtual impedance correlated with a droop controller. This paper...... objective was to validate the simulation on a laboratory platform using 15 kW Voltage Source Converters (VSC) and a Real Time Interface (RTI). As a result, the power sharing is validated using such methodology and the influence in the parameters can be evaluated...

  18. Transmission prices in the electric system. Technical constraints and economic efficiency

    International Nuclear Information System (INIS)

    Polidori, P.

    1999-01-01

    This article analyses the two main models at the core of today's theoretical discussion on transmission pricing in electricity sectors under competition. The first aim of the paper is showing how technical constraints that characterise transmission systems may affect energy production and transmission and therefore the definition of the price system for using the electric grid. The second aim of the paper is showing how it is possible to suggest solutions, although not free from limitations, that can be used for an efficient management of electric systems characterised by generation and consumption sectors under competition [it

  19. Off-shore wind power plant modelling precision and efficiency in electromagnetic transient simulation programs

    Energy Technology Data Exchange (ETDEWEB)

    Karaagac, U.; Saad, H.; Mahseredjian, J. [Ecole Polytechnique de Montreal, Montreal, QC (Canada); Jensen, S.; Cai, L. [REpower Systems AG, Hamburg (Germany)

    2012-07-01

    The large number of switching elements in the modular multilevel converter (MMC) is a challenging problem for modeling the MMC-HVDC systems in electromagnetic transient type (EMT-type) programs. The modeling complexity increases even further when MMC-HVDC systems are used to integrate offshore wind farms (OWFs) with power electronics based wind energy converters, such as doubly-fed induction generators (DFIGs). This paper compares the computational performances of various combinations of MMC-HVDC and OWF models. Practical onshore ac fault scenarios are simulated for an OWF composed of DFIG type wind turbines and connected to a practical ac grid through a point-to-point MMC-HVDC system. (orig.)

  20. Combined heuristic with fuzzy system to transmission system expansion planning

    Energy Technology Data Exchange (ETDEWEB)

    Silva Sousa, Aldir; Asada, Eduardo N. [University of Sao Paulo, Sao Carlos School of Engineering, Department of Electrical Engineering Av. Trabalhador Sao-carlense, 400, 13566-590 Sao Carlos, SP (Brazil)

    2011-01-15

    A heuristic algorithm that employs fuzzy logic is proposed to the power system transmission expansion planning problem. The algorithm is based on the divide to conquer strategy, which is controlled by the fuzzy system. The algorithm provides high quality solutions with the use of fuzzy decision making, which is based on nondeterministic criteria to guide the search. The fuzzy system provides a self-adjusting mechanism that eliminates the manual adjustment of parameters to each system being solved. (author)

  1. Radiation transmission pipe thickness measurement system

    International Nuclear Information System (INIS)

    Higashi, Yasuhiko

    2010-01-01

    Fuji Electric Systems can be measured from the outer insulation of the transmission Characteristics and radiation detection equipment had been developed that can measure pipe wall thinning in plant and running, the recruitment of another three-beam calculation method by pipe thickness measurement system was developed to measure the thickness of the pipe side. This equipment has been possible to measure the thickness of the circumferential profile of the pipe attachment by adopting automatic rotation. (author)

  2. Transmission computed tomography data acquisition with a SPECT system

    International Nuclear Information System (INIS)

    Greer, K.L.; Harris, C.C.; Jaszczak, R.J.; Coleman, R.E.; Hedlund, L.W.; Floyd, C.E.; Manglos, S.H.

    1987-01-01

    Phantom and animal transmission computed tomography (TCT) scans were performed with a camera-based single photon emission computed tomography (SPECT) system to determine system linearity as a function of object density, which is important in the accurate determination of attenuation coefficients for SPECT attenuation compensation. Results from phantoms showed promise in providing a linear relationship in measuring density while maintaining good image resolution. Animal images were essentially free of artifacts. Transmission computed tomography scans derived from a SPECT system appear to have the potential to provide data suitable for incorporation in an attenuation compensation algorithm at relatively low (calculated) radiation doses to the subjects

  3. A comprehensive analysis and hardware implementation of control strategies for high output voltage DC-DC boost power converter

    OpenAIRE

    Padmanaban, Sanjeevikumar; Grandi, Gabriele; Blaabjerg, Frede; Wheeler, Patrick; Siano, Pierluigi; Hammami, Manel

    2017-01-01

    Classical DC-DC converters used in high voltage direct current (HVDC) power transmission systems, lack in terms of efficiency, reduced transfer gain and increased cost with sensor (voltage/current) numbers. Besides, the internal self-parasitic behavior of the power components reduces the output voltage and efficiency of classical HV converters. This paper deals with extra high-voltage (EHV) dc-dc boost converter by the application of voltage-lift technique to overcome the aforementioned defic...

  4. Downhole transmission system comprising a coaxial capacitor

    Science.gov (United States)

    Hall, David R [Provo, UT; Pixton, David S [Lehi, UT; Johnson, Monte L [Orem, UT; Bartholomew, David B [Springville, UT; Hall, Jr., H. Tracy; Rawle, Michael [Springville, UT

    2011-05-24

    A transmission system in a downhole component comprises a plurality of data transmission elements. A coaxial cable having an inner conductor and an outer conductor is disposed within a passage in the downhole component such that at least one capacitor is disposed in the passage and having a first terminal coupled to the inner conductor and a second terminal coupled to the outer conductor. Preferably the transmission element comprises an electrically conducting coil. Preferably, within the passage a connector is adapted to electrically connect the inner conductor of the coaxial cable and the lead wire. The coaxial capacitor may be disposed between and in electrically communication with the connector and the passage. In another embodiment a connector is adapted to electrical connect a first and a second portion of the inner conductor of the coaxial cable and a coaxial capacitor is in electrical communication with the connector and the passage.

  5. Subcarrier multiplexing tolerant dispersion transmission system employing optical broadband sources.

    Science.gov (United States)

    Grassi, Fulvio; Mora, José; Ortega, Beatriz; Capmany, José

    2009-03-16

    This paper presents a novel SCM optical transmission system for next-generation WDM-PONs combining broadband optical sources and a Mach-Zehnder interferometric structure. The approach leeds to transport RF signals up to 50 GHz being compatible with RoF systems since a second configuration has been proposed in order to overcome dispersion carrier suppression effect using DSB modulation. The theoretical analysis validates the potentiality of the system also considering the effects of the dispersion slope over the transmission window. (c) 2009 Optical Society of America

  6. Application of WebSphere MQ in data transmission of retail system

    Directory of Open Access Journals (Sweden)

    Ma Yue

    2017-02-01

    Full Text Available Considering the requirements of enterprise data communication system functions,this article uses WebSphere message queue (MQ technology to ensure effective data transmission for large amount of commercial files.Taking daily sales data transmission between foreground and background as example,we design and realize the typical retail data transmission function.

  7. Impedance matching wireless power transmission system for biomedical devices.

    Science.gov (United States)

    Lum, Kin Yun; Lindén, Maria; Tan, Tian Swee

    2015-01-01

    For medical application, the efficiency and transmission distance of the wireless power transfer (WPT) are always the main concern. Research has been showing that the impedance matching is one of the critical factors for dealing with the problem. However, there is not much work performed taking both the source and load sides into consideration. Both sides matching is crucial in achieving an optimum overall performance, and the present work proposes a circuit model analysis for design and implementation. The proposed technique was validated against experiment and software simulation. Result was showing an improvement in transmission distance up to 6 times, and efficiency at this transmission distance had been improved up to 7 times as compared to the impedance mismatch system. The system had demonstrated a near-constant transfer efficiency for an operating range of 2cm-12cm.

  8. Creating a robust and integrated electrical transmission system

    International Nuclear Information System (INIS)

    McLain, S.

    2004-01-01

    The service territory for Puget Sound Energy (PSE) was presented in terms of electric power and gas transmission. Issues affecting the Puget Sound area include high growth and the west coast energy crisis which has had an adverse financial impact on the power industry. The transmission system is basically at capacity and has been impacted by imports and exports between the United States and Canada. Other issues include the separation between energy resources and transmission, modernizing the power grid, and challenges for independent power producers (IPPs). The Northwest Transmission Assessment Committee (NTAC), which was formed under the Northwest Power Pool, has the potential to bring interested parties to study constrained paths and to plan a single utility concept for the region. It is expected that new challenges such as financing and risk management will emerge once the technical solutions are identified and agreed upon. The issue of enforceable and mandatory reliability standards was also discussed. 1 fig

  9. 47 CFR 73.875 - Modification of transmission systems.

    Science.gov (United States)

    2010-10-01

    .... (2) Those that would cause the transmission system to exceed the equipment performance measurements... radiofrequency radiation guidelines. In addition, applications solely filed pursuant to paragraphs (c)(1) or (c...

  10. Transmission Quality Measurements in DAB+ Broadcast System

    Directory of Open Access Journals (Sweden)

    Gilski Przemysław

    2017-12-01

    Full Text Available In the age of digital media, delivering broadcast content to customers at an acceptable level of quality is one of the most challenging tasks. The most important factor is the efficient use of available resources, including bandwidth. An appropriate way of managing the digital multiplex is essential for both the economic and technical issues. In this paper we describe transmission quality measurements in the DAB+ broadcast system. We provide a methodology for analysing parameters and factors related with the efficiency and reliability of a digital radio link. We describe a laboratory stand that can be used for transmission quality assessment on a regional and national level.

  11. Centralized Coordination of Load Shedding & Protection System of Transmission Lines

    DEFF Research Database (Denmark)

    Hoseinzadeh, Bakhtyar; Bak, Claus Leth

    2018-01-01

    The power system integrity is vulnerable to thermal limit of transmission lines due to overloading and consequently activation of their protection devices following severe contingencies. In this paper, the loading rate of transmission lines is monitored online and is considered in the centralized......, over current protection....

  12. Transmission problem for the Brinkman system

    Czech Academy of Sciences Publication Activity Database

    Medková, Dagmar

    2014-01-01

    Roč. 59, č. 12 (2014), s. 1664-1678 ISSN 1747-6933 R&D Projects: GA ČR(CZ) GAP201/11/1304 Institutional support: RVO:67985840 Keywords : Brinkman system * transmission problem * single- layer potential * double layer potential Subject RIV: BA - General Mathematics Impact factor: 0.610, year: 2014 http://www.tandfonline.com/doi/abs/10.1080/17476933.2013.870563

  13. Multi-Port High Voltage Gain Modular Power Converter for Offshore Wind Farms

    Directory of Open Access Journals (Sweden)

    Sen Song

    2018-06-01

    Full Text Available In high voltage direct current (HVDC power transmission of offshore wind power systems, DC/DC converters are applied to transfer power from wind generators to HVDC terminals, and they play a crucial role in providing a high voltage gain, high efficiency, and high fault tolerance. This paper introduces an innovative multi-port DC/DC converter with multiple modules connected in a scalable matrix configuration, presenting an ultra-high voltage step-up ratio and low voltage/current rating of components simultaneously. Additionally, thanks to the adoption of active clamping current-fed push–pull (CFPP converters as sub-modules (SMs, soft-switching is obtained for all power switches, and the currents of series-connected CFPP converters are auto-balanced, which significantly reduce switching losses and control complexity. Furthermore, owing to the expandable matrix structure, the output voltage and power of a modular converter can be controlled by those of a single SM, or by adjusting the column and row numbers of the matrix. High control flexibility improves fault tolerance. Moreover, due to the flexible control, the proposed converter can transfer power directly from multiple ports to HVDC terminals without bus cable. In this paper, the design of the proposed converter is introduced, and its functions are illustrated by simulation results.

  14. APEnet+ 34 Gbps data transmission system and custom transmission logic

    International Nuclear Information System (INIS)

    Ammendola, R; Biagioni, A; Frezza, O; Lonardo, A; Cicero, F Lo; Paolucci, P S; Rossetti, D; Simula, F; Tosoratto, L; Vicini, P

    2013-01-01

    APEnet+ is a point-to-point, low-latency, 3D-torus network controller integrated in a PCIe Gen2 board based on the Altera Stratix IV FPGA. We characterize the transmission system (embedded transceivers driving external QSFP+ modules) analyzing signal integrity, throughput, latency, BER and jitter at different data rates up to 34 Gbps. We estimate the efficiency of a custom logic able to sustain 2.6 GB/s per link with an FPGA on-chip memory footprint of 40 KB, providing deadlock-free routing and systemic awareness of faults. Finally, we show the preliminary results obtained with the embedded transceivers of a next-generation FPGA and outline some ideas to increase the performance with the same FPGA memory footprint

  15. APEnet+ 34 Gbps data transmission system and custom transmission logic

    Energy Technology Data Exchange (ETDEWEB)

    Ammendola, R [INFN Sezione di Roma Tor Vergata, Via della Ricerca Scientifica, 1 - 00133 Roma Italy (Italy); Biagioni, A; Frezza, O; Lonardo, A; Cicero, F Lo; Paolucci, P S; Rossetti, D; Simula, F; Tosoratto, L; Vicini, P [INFN Sezione di Roma, P.le Aldo Moro, 2 - 00185 Roma Italy (Italy)

    2013-12-01

    APEnet+ is a point-to-point, low-latency, 3D-torus network controller integrated in a PCIe Gen2 board based on the Altera Stratix IV FPGA. We characterize the transmission system (embedded transceivers driving external QSFP+ modules) analyzing signal integrity, throughput, latency, BER and jitter at different data rates up to 34 Gbps. We estimate the efficiency of a custom logic able to sustain 2.6 GB/s per link with an FPGA on-chip memory footprint of 40 KB, providing deadlock-free routing and systemic awareness of faults. Finally, we show the preliminary results obtained with the embedded transceivers of a next-generation FPGA and outline some ideas to increase the performance with the same FPGA memory footprint.

  16. A Common Definition of the System Operators' Core Activities[Electric Power Transmission System Operator

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-02-15

    In this report a common definition of the system operator's core activities in the Nordic countries is identified and also a list of non-core activities is introduced. As a starting point the common tasks for system responsibility as identified by Nordel has been used for the work. The term TSO (Transmission System Operator) is employed as a common denominator in the report. It is found out that the TSOs carry out common core activities in the roles as a transmission operator, a system operator and a balance settlement responsible. The core activities for the TSO as a transmission network operator are: Maintain the adequate transmission system in the long run and network development plan on the national as well as on the Nordic level using sophisticated analysis and planning methods and tools. Plan the transmission network on the national as well as on the Nordic level utilising new investments, renewal and maintenance of existing network components so that the network is secure to operate and adequate transmission capacity is guaranteed. Aim at timely network expansions using enhanced information exchange between the Nordic TSOs, and on the national level between the TSO and distribution and regional network operators, large consumers and large producers. Secure the technical compatibility with networks across the border and within a country by establishing connection requirements on the national level and ensuring that the national requirements are compatible across the Nordic power system. The core activities for the TSO as a system operator are: Define common technical requirements for the secure system operation using common planning, operation, connection and data exchange procedures. Secure the system operation with the operational planning for the following year by using information exchange between TSOs enabling the TSOs to make the best possible forecast of the global grid situation in order to assess the flows in their network and the available

  17. Synchronization of uncertain chaotic systems using a single transmission channel

    International Nuclear Information System (INIS)

    Feng Yong; Yu Xinghuo; Sun Lixia

    2008-01-01

    This paper proposes a robust sliding mode observer for synchronization of uncertain chaotic systems with multi-nonlinearities. A new control strategy is proposed for the construction of the robust sliding mode observer, which can avoid the strict conditions in the design process of Walcott-Zak observer. A new method of multi-dimensional signal transmission via single transmission channel is proposed and applied to chaos synchronization of uncertain chaotic systems with multi-nonlinearities. The simulation results are presented to validate the method

  18. Transmission dispatch and congestion management in open market systems

    Science.gov (United States)

    Fang, Risheng

    This thesis is located in the domain of electricity supply industry restructuring. It deals with emerging issues, whose understanding is essential to advancing knowledge of open access transmission theory and proceeds to develop approaches for solving the transmission dispatch and congestion management problem. An overview of current trends and experiences in utility restructuring and the main models for restructuring, as well as the classifications of system operators, is first presented. A fully unbundled competitive electricity market model, called the bilateral/multilateral trades model, is then developed. A survey of current research in transmission dispatch and congestion management is included with discussion of transmission capacity and ancillary services. A methodology for the power dispatch problem in a structure dominated by bilateral and multilateral transmission contracts is presented. Group structures are mathematically formulated and explored and three basic types of curtailment strategies proposed for use by market participants. A more complex model is then developed, which takes into account the co-existence of bilateral and multilateral contracts with pool type dynamic supplies and demands based on bids and market clearing prices. An integrated dispatch strategy to reconcile all three types of transactions (bilateral, multilateral and pool) is then developed. Prioritization of electricity transactions and related curtailment strategies are explored and a mechanism for coordination between market participants to achieve additional economic advantages is described. A theory of security based rescheduling is presented in order to investigate the security-related aspects of operation in an unbundled and deregulated system. The impact of post-contingency corrective capability on optimal rescheduling results has been identified and the advantage of incorporating post-contingency corrective rescheduling into the objective function demonstrated. Finally

  19. Calculation and application of energy transaction allocation factors in electric power transmission systems

    Science.gov (United States)

    Fradi, Aniss

    The ability to allocate the active power (MW) loading on transmission lines and transformers, is the basis of the "flow based" transmission allocation system developed by the North American Electric Reliability Council. In such a system, the active power flows must be allocated to each line or transformer in proportion to the active power being transmitted by each transaction imposed on the system. Currently, this is accomplished through the use of the linear Power Transfer Distribution Factors (PTDFs). Unfortunately, no linear allocation models exist for other energy transmission quantities, such as MW and MVAR losses, MVAR and MVA flows, etc. Early allocation schemes were developed to allocate MW losses due to transactions to branches in a transmission system, however they exhibited diminished accuracy, since most of them are based on linear power flow modeling of the transmission system. This thesis presents a new methodology to calculate Energy Transaction Allocation factors (ETA factors, or eta factors), using the well-known process of integration of a first derivative function, as well as consistent and well-established mathematical and AC power flow models. The factors give a highly accurate allocation of any non-linear system quantity to transactions placed on the transmission system. The thesis also extends the new ETA factors calculation procedure to restructure a new economic dispatch scheme where multiple sets of generators are economically dispatched to meet their corresponding load and their share of the losses.

  20. Coordinated Transmissions to Direct and Relayed Users in Wireless Cellular Systems

    DEFF Research Database (Denmark)

    Thai, Chan; Popovski, Petar; Kaneko, Megumi

    2011-01-01

    The ideas of wireless network coding at the physical layer promise high throughput gains in wireless systems with relays and multi–way traffic flows. This gain can be ascribed to two principles: (1) joint transmission of multiple communication flows and (2) usage of a priori information to cancel...... the interference. In this paper we use these principles to devise new transmission schemes in wireless cellular systems that feature both users served directly by the base stations (direct users) and users served through relays (relayed users). We present four different schemes for coordinated transmission...... of uplink and downlink traffic in which one direct and one relayed user are served. These schemes are then used as building blocks in multi–user scenarios, where we present several schemes for scheduling pairs of users for coordinated transmissions. The optimal scheme involves exhaustive search of the best...

  1. Coordinated frequency control from offshore wind power plants connected to multi terminal DC system considering wind speed variation

    DEFF Research Database (Denmark)

    Sakamuri, Jayachandra N.; Altin, Müfit; Hansen, Anca Daniela

    2017-01-01

    A coordinated fast primary frequency control scheme from offshore wind power plants (OWPPs) integrated to a three terminal high voltage DC (HVDC) system is proposed in this study. The impact of wind speed variation on the OWPP active power output and thus on the AC grid frequency and DC grid...... the active power support from OWPP with a ramp rate limiter and (iii) An alternative method for the wind turbine overloading considering rotor speed. The effectiveness of the proposed control scheme is demonstrated on a wind power plant integrated into a three terminal HVDC system developed in DIg......SILIENT PowerFactory. The results show that the proposed coordinated frequency control method performs effectively at different wind speeds and minimises the secondary effects on frequency and DC voltage....

  2. Pressure control of a pneumatic control system with a long transmission line

    International Nuclear Information System (INIS)

    Jang, Ji Seong; Lee, Kwang Kuk; Choi, Myung Soo

    2003-01-01

    In this study, a robust controller to control pressure in a pneumatic pressure vessel with a long transmission line is proposed. Frequency response of transmission line using compressible fluid is changed by the flowing state of the fluid. So, if a fixed gain controller designed based on a model supposed the flowing state to a specific state, the performance of the control system could be degraded because of the modelling error. The controller designed in this study is composed of two parts. One is a feedback controller to improve a feedback characteristics and to compensate the influence of the variation of transfer characteristics of a transmission line owing to the change of flowing state and the other is a feed forward controller to regulate command following performance. The experimental results with the designed controller show that the robustness of the control system is achieved regardless of the change of the model of the transmission line. Therefore, the designed controller can be utilized for the performance improvement of a pressure control system with a long transmission line using compressible fluid

  3. Neutral Beam Power System for TPX

    International Nuclear Information System (INIS)

    Ramakrishnan, S.; Bowen, O.N.; O'Conner, T.; Edwards, J.; Fromm, N.; Hatcher, R.; Newman, R.; Rossi, G.; Stevenson, T.; von Halle, A.

    1993-01-01

    The Tokamak Physics Experiment (TPX) will utilize to the maximum extent the existing Tokamak Fusion Test Reactor (TFTR) equipment and facilities. This is particularly true for the TFTR Neutral Beam (NB) system. Most of the NB hardware, plant facilities, auxiliary sub-systems, power systems, service infrastructure, and control systems can be used as is. The major changes in the NB hardware are driven by the new operating duty cycle. The TFTR Neutral Beam was designed for operation of the Sources for 2 seconds every 150 seconds. The TPX requires operation for 1000 seconds every 4500 seconds. During the Conceptual Design Phase of TPX every component of the TFTR NB Electrical Power System was analyzed to verify whether the equipment can meet the new operational requirements with our without modifications. The Power System converts 13.8 kV prime power to controlled pulsed power required at the NB sources. The major equipment involved are circuit breakers, auto and rectifier transformers surge suppression components, power tetrodes, HV Decks, and HVDC power transmission to sources. Thermal models were developed for the power transformers to simulate the new operational requirements. Heat runs were conducted for the power tetrodes to verify capability. Other components were analyzed to verify their thermal limitations. This paper describes the details of the evaluation and redesign of the electrical power system components to meet the TPX operational requirements

  4. Issues affecting the electricity transmission system in Mexico under a competitive integrated model

    Energy Technology Data Exchange (ETDEWEB)

    Avila Rosales, M.A.; Gonzalez Flores, J. [Federal Electricity Commission, Mexico City (Mexico)

    2008-07-01

    The electricity sector in Mexico is undergoing a process of significant structural change. The traditional industry framework has been exposed to new market structures and greater competition, both of which are being introduced by changing regulations regarding who can generate, transmit, distribute and sell electricity. Mexico's power industry is changing to a competitive integrated model. Electricity industry restructuring is partly based on the assumption that transmission systems should be flexible, reliable, and open to all exchanges no matter where the suppliers and consumers of energy are located and who they are. However, neither the existing transmission systems nor its management infrastructure can fully support this open exchange. This paper described the primary issues affecting the transmission system in Mexico under a competitive environment and a transmission expansion planning approach that took the uncertainties associated with the location and size of new generating power stations into consideration in order to produce least-cost and robust transmission plans. The paper described the planning process, including a rigorous analysis of the economics of the resulting transmission plans. Specifically, the paper described the current regulatory framework and supply adequacy as well as current procedures and methodologies for transmission management and expansion planning. The transmission planning methodology was also presented. This included a minimum cost analysis; profit analysis; and least-cost transmission plan. It was concluded that the transmission expansion planning approach stressed that a horizon year viewpoint was important because transmission additions have long-term use. The transmission expansion planning approach, further defined the process of selecting transmission projects as one of comparing and optimizing attributes such as near-term needs; long-term utilization; contribution to overall reliability; and favorable or least

  5. Concept design of the high voltage transmission system for the collider tunnel

    International Nuclear Information System (INIS)

    Norman, L.S.

    1992-03-01

    In order to provide electrical service to the Superconducting Super Collider Laboratory (SSCL) 54-mile-circumference collider of 125 MVA at 69 kV or 155 MVA at 138 kV of distributed power, it must be demonstrated that the concept design for a high-voltage transmission system can meet the distribution requirements of the collider electrical system with its cryogenic system's large motor loads and its pulsed power technical systems. It is a practical design, safe for operating personnel and cost-effective. The normal high-voltage transmission techniques of overhead and underground around the 54-mile collider tunnel could not be applied because of technical and physical constraints, or was environmentally unacceptable. The approach taken to solve these problems is the installation of 69-kV or 138-kV exposed solid dielectric transmission cable inside the collider tunnel with the superconducting magnets, cryogenic piping, electrical medium, and low-voltage distribution systems, and electronic/instrumentation wiring systems. This mixed-use approach has never been attempted in a collider tunnel. Research into all aspects of the engineering and installation problems and consultation with transmission cable manufacturers, electrical utilities, and European entities with similar installations -- such as the Channel Tunnel -- demonstrate that the concept design is feasible and practical. This paper presents a history of the evolution of the concept design. Design studies are underway to determine the system configuration and voltages. Included in this report are tunnel transmission cable system considerations and evaluation of solid dielectric high-voltage cable design

  6. Concept design of the high-voltage transmission system for the collider tunnel

    International Nuclear Information System (INIS)

    Norman, L.S.

    1992-01-01

    In order to provide electrical service to the Superconducting Super Collider Laboratory (SSCL) 54-mile-circumference collider of 125 MVA at 69 kV or 155 MVA at 138 kV of distributed power, it must be demonstrated that the concept design for a high-voltage transmission system can meet the distribution requirements of the collider electrical system with its cryogenic system's large motor loads and its pulsed power technical systems. It is a practical design, safe for operating personnel and cost-effective. The normal high-voltage transmission techniques of overhead and underground around the 54-mile collider tunnel could not be applied because of technical and physical constraints, or was environmentally unacceptable. The approach taken to solve these problems is the installation of 69-kV or 138-kV exposed solid dielectric transmission cable inside the collider tunnel with the superconducting magnets, cryogenic piping, electrical medium, and low-voltage distribution systems, and electronic/instrumentation wiring systems. This mixed-use approach has never been attempted in a collider tunnel. Research into all aspects of the engineering and installation problems and consultation with transmission cable manufacturers, electrical utilities, and European entities with similar installations-such as the Channel Tunnel-demonstrate that the concept design is feasible and practical. This paper presents a history of the evolution of the concept design. Design studies are underway to determine the system configuration and voltages. Included in this report are tunnel transmission cable system considerations and evaluation of solid dielectric high-voltage cable design

  7. Health monitoring system for transmission shafts based on adaptive parameter identification

    Science.gov (United States)

    Souflas, I.; Pezouvanis, A.; Ebrahimi, K. M.

    2018-05-01

    A health monitoring system for a transmission shaft is proposed. The solution is based on the real-time identification of the physical characteristics of the transmission shaft i.e. stiffness and damping coefficients, by using a physical oriented model and linear recursive identification. The efficacy of the suggested condition monitoring system is demonstrated on a prototype transient engine testing facility equipped with a transmission shaft capable of varying its physical properties. Simulation studies reveal that coupling shaft faults can be detected and isolated using the proposed condition monitoring system. Besides, the performance of various recursive identification algorithms is addressed. The results of this work recommend that the health status of engine dynamometer shafts can be monitored using a simple lumped-parameter shaft model and a linear recursive identification algorithm which makes the concept practically viable.

  8. Design of free-space optical transmission system in computer tomography equipment

    Science.gov (United States)

    Liu, Min; Fu, Weiwei; Zhang, Tao

    2018-04-01

    Traditional computer tomography (CT) based on capacitive coupling cannot satisfy the high data rate transmission requirement. We design and experimentally demonstrate a free-space optical transmission system for CT equipment at a data rate of 10 Gb / s. Two interchangeable sections of 12 pieces of fiber with equal length is fabricated and tested by our designed laser phase distance measurement system. By locating the 12 collimators in the edge of the circle wheel evenly, the optical propagation characteristics for the 12 wired and wireless paths are similar, which can satisfy the requirement of high-speed CT transmission system. After bit error rate (BER) measurement in several conditions, the BER performances are below the value of 10 - 11, which has the potential in the future application scenario of CT equipment.

  9. Transmission system planning in Ontario

    Energy Technology Data Exchange (ETDEWEB)

    Barrie, D; Macedo, F X; Mcconnach, J S [Ontario Hydro, Toronto, ON (Canada)

    1994-12-31

    In recent years, new and modified approaches to planning the large transmission system that serves the province of Ontario, Canada, have been necessary to accommodate the rapidly changing planning environment including slower uncertain growth, ageing of facilities, integration of demand side management and non utility generation options, increased competitiveness, increased financial stresses and affordable constraints. This paper describes some of the new and modified approaches and tools that have been adopted or are being developed by Ontario Hydro to cope with this changing environment. (author) 9 refs., 4 figs.

  10. Characterization of a 300-GHz Transmission System for Digital Communications

    Science.gov (United States)

    Hudlička, Martin; Salhi, Mohammed; Kleine-Ostmann, Thomas; Schrader, Thorsten

    2017-08-01

    The paper presents the characterization of a 300-GHz transmission system for modern digital communications. The quality of the modulated signal at the output of the system (error vector magnitude, EVM) is measured using a vector signal analyzer. A method using a digital real-time oscilloscope and consecutive mathematical processing in a computer is shown for analysis of signals with bandwidths exceeding that of state-of-the-art vector signal analyzers. The uncertainty of EVM measured using the real-time oscilloscope is open to analysis. Behaviour of the 300-GHz transmission system is studied with respect to various modulation schemes and different signal symbol rates.

  11. Impedance Synthesis Based Vibration Analysis of Geared Transmission System

    Directory of Open Access Journals (Sweden)

    Yafeng Ren

    2017-01-01

    Full Text Available The severity of gear noise response depends on the sensitivity of geared rotor system dynamics to the transmission error. As gearbox design trending towards lighter weight and lower noise, the influence of housing compliance on system dynamic characteristics cannot be ignored. In this study, a gear-shaft-bearing-housing coupled impedance model is proposed to account for the effect of housing compliance on the vibration of geared transmission system. This proposed dynamic model offers convenient modeling, efficient computing, and ability to combine computed parameters with experimental ones. The numerical simulations on system dynamic characteristics are performed for both a rigid housing configuration and a flexible one. Natural frequencies, dynamic mesh forces, and dynamic bearing reaction loads are computed, and the housing compliance contribution on system dynamic characteristics is analyzed. Results show that increasing housing compliance will decrease the system natural frequencies and will affect the dynamic bearing reaction loads significantly but have very little influence on the dynamic mesh force. Also, the analysis shows that bearing stiffness has significant influence on the degree of housing contribution on system dynamic characteristics.

  12. Study on frequency characteristics of wireless power transmission system based on magnetic coupling resonance

    Science.gov (United States)

    Liang, L. H.; Liu, Z. Z.; Hou, Y. J.; Zeng, H.; Yue, Z. K.; Cui, S.

    2017-11-01

    In order to study the frequency characteristics of the wireless energy transmission system based on the magnetic coupling resonance, a circuit model based on the magnetic coupling resonant wireless energy transmission system is established. The influence of the load on the frequency characteristics of the wireless power transmission system is analysed. The circuit coupling theory is used to derive the minimum load required to suppress frequency splitting. Simulation and experimental results verify that when the load size is lower than a certain value, the system will appear frequency splitting, increasing the load size can effectively suppress the frequency splitting phenomenon. The power regulation scheme of the wireless charging system based on magnetic coupling resonance is given. This study provides a theoretical basis for load selection and power regulation of wireless power transmission systems.

  13. R and D of seismic emergency information transmission system

    International Nuclear Information System (INIS)

    Ebisawa, Katsumi; Kuno, Tetsuya; Shibata, Katsuyuki; Abe, Ichiro; Tuzuki, Kazuhisa

    2002-01-01

    The R and D Seismic Emergency Information Transmission System has been conducted involving the latest progress in earthquake engineering with regard to estimation techniques on the hypocenter, fault and earthquake motion parameters and in information technologies. This system is the disaster management system which consists of user site and disaster information center and is capable of mutual information transmission through Inter-Net and walkie-talkie. The concept of the disaster management system which is adaptable with DiMSIS (Disaster Management Spatial Information System) developed by professor Kameda et al. of Kyoto University has been established. Based on this concept, a prototype system has been developed. This system has following functions, (1) compatible application both in usual condition and emergency time, (2) the decentralized independence, and (3) the integration of space and time information. The system can estimate the earthquake motion information with 500 m square mesh in a local area and transmit in a few minutes. In the development of the system, seismometer network, surface soil database and amplification functions were prepared for the examination of system function. Demonstration against the Tokai area was carried out and the function was verified. (author)

  14. Wireless OAM transmission system based on elliptical microstrip patch antenna.

    Science.gov (United States)

    Chen, Jia Jia; Lu, Qian Nan; Dong, Fei Fei; Yang, Jing Jing; Huang, Ming

    2016-05-30

    The multiplexing transmission has always been a focus of attention for communication technology. In this paper, the radiation characteristics of circular microstrip patch antenna was firstly analyzed based on cavity model theory, and then spiral beams carrying orbital angular momentum (OAM) were generated, using elliptical microstrip patch antenna, with a single feed probe instead of a standard circular patch with two feedpoints. Moreover, by combining the proposed elliptic microstrip patch antenna with Universal Software Radio Peripheral (USRP), a wireless OAM transmission system was established and the real-time transmission of text, image and video in a real channel environment was realized. Since the wireless OAM transmission has the advantage of good safety and high spectrum utilization efficiency, this work has theoretical significance and potential application.

  15. System Reliability Evaluation of Data Transmission in Commercial Banks with Multiple Branches

    Directory of Open Access Journals (Sweden)

    Yi-Kuei Lin

    2014-01-01

    Full Text Available The main purpose of this paper is to assess the system reliability of electronic transaction data transmissions made by commercial banks in terms of stochastic flow network. System reliability is defined as the probability of demand satisfaction and it can be used to measure quality of service. In this paper, we study the system reliability of data transmission from the headquarters of a commercial bank to its multiple branches. The network structure of the bank and the probability of successful data transmission are obtained through the collection of real data. The system reliability, calculated using the minimal path method and the recursive sum of disjoint products algorithm, provides banking managers with a view to comprehend the current state of the entire system. Besides, the system reliability can be used not only as a measurement of quality of service, but also an improvement reference of the system by adopting sensitivity analysis.

  16. Hybrid wireless-over-fiber transmission system based on multiple injection-locked FP LDs.

    Science.gov (United States)

    Li, Chung-Yi; Lu, Hai-Han; Chu, Chien-An; Ying, Cheng-Ling; Lu, Ting-Chien; Peng, Peng-Chun

    2015-07-27

    A hybrid wireless-over-fiber (WoF) transmission system based on multiple injection-locked Fabry-Perot laser diodes (FP LDs) is proposed and experimentally demonstrated. Unlike the traditional hybrid WoF transmission systems that require multiple distributed feedback (DFB) LDs to support different kinds of services, the proposed system employs multiple injection-locked FP LDs to provide different kinds of applications. Such a hybrid WoF transmission system delivers downstream intensity-modulated 20-GHz microwave (MW)/60-GHz millimeter-wave (MMW)/550-MHz cable television (CATV) signals and upstream phase-remodulated 20-GHz MW signal. Excellent bit error rate (BER), carrier-to-noise ratio (CNR), composite second-order (CSO), and composite triple-beat (CTB) are observed over a 40-km single-mode fiber (SMF) and a 4-m radio frequency (RF) wireless transport. Such a hybrid WoF transmission system has practical applications for fiber-wireless convergence to provide broadband integrated services, including telecommunication, data communication, and CATV services.

  17. Fiber-optic data-transmission system for borehole logging. Final report. National Uranium Resource Evaluation

    International Nuclear Information System (INIS)

    Gould, G.

    1981-01-01

    The purpose of the system is to provide signal transmission media for transmission of digital data from a borehole logging probe (and associated processor-electronics) to a borehole logging truck at the surface. This fiber optic transmission system is specifically designed for use on the Bendix Field Engineering Corp. (BFEC) R and D logging truck

  18. Long-Haul Dense Space Division Multiplexed Transmission over Low-Crosstalk Heterogeneous 32-Core Transmission Line Using Partial Recirculating Loop System

    DEFF Research Database (Denmark)

    Mizuno, Takayuki; Shibahara, Kohki; Ye, Feihong

    2017-01-01

    In this paper, we present long-haul 32-core dense space division multiplexed (DSDM) unidirectional transmission over a single-mode multicore transmission line. We developed a low-crosstalk heterogeneous 32-core fiber with a square lattice arrangement, and a novel partial recirculating loop system...

  19. Increase in fault ride through capability of direct drive permanent magnet based wind farm using VSC-HVDC

    International Nuclear Information System (INIS)

    Maleki, Hesamaldin; Ramachandaramurthy, V K; Lak, Moein

    2013-01-01

    Burning of fossil fuels and green house gasses causes global warming. This has led to governments to explore the use of green energies instead of fossil fuels. The availability of wind has made wind technology a viable alternative for generating electrical power. Hence, many parts of the world, especially Europe are experiencing a growth in wind farms. However, by increasing the number of wind farms connected to the grid, power quality and voltage stability of grid becomes a matter of concern. In this paper, VSC-HVDC control strategy which enables the wind farm to ride-through faults and regulate voltage for fault types is proposed. The results show that the wind turbine output voltage fulfills the E.ON grid code requirements, when subjected to three phase to ground fault. Hence, continues operation of the wind farm is achieved.

  20. Increase in fault ride through capability of direct drive permanent magnet based wind farm using VSC-HVDC

    Science.gov (United States)

    Maleki, Hesamaldin; Ramachandaramurthy, V. K.; Lak, Moein

    2013-06-01

    Burning of fossil fuels and green house gasses causes global warming. This has led to governments to explore the use of green energies instead of fossil fuels. The availability of wind has made wind technology a viable alternative for generating electrical power. Hence, many parts of the world, especially Europe are experiencing a growth in wind farms. However, by increasing the number of wind farms connected to the grid, power quality and voltage stability of grid becomes a matter of concern. In this paper, VSC-HVDC control strategy which enables the wind farm to ride-through faults and regulate voltage for fault types is proposed. The results show that the wind turbine output voltage fulfills the E.ON grid code requirements, when subjected to three phase to ground fault. Hence, continues operation of the wind farm is achieved.