WorldWideScience

Sample records for hvac system configurations

  1. HVAC systems design handbook

    CERN Document Server

    Haines, Roger W

    2010-01-01

    Thoroughly updated with the latest codes, technologies, and practices, this all-in-one resource provides details, calculations, and specifications for designing efficient and effective residential, commercial, and industrial HVAC systems. HVAC Systems Design Handbook, Fifth Edition, features new information on energy conservation and computer usage for design and control, as well as the most recent International Code Council (ICC) Mechanical Code requirements. Detailed illustrations, tables, and essential HVAC equations are also included. This comprehensive guide contains everything you need to design, operate, and maintain peak-performing HVAC systems.

  2. Next Generation HVAC System

    Science.gov (United States)

    Takagi, Yasuo; Murakami, Yoshiki; Hanada, Yuuichi; Nishimura, Nobutaka; Yamazaki, Kenichi; Itoh, Yasuyuki

    A new HVAC (Heating, Ventilating, and Air-Conditioning) system for buildings is proposed. The key technology for the system is a twin coil air handling unit (AHU) and its advanced control method. One coil is equipped to cool and dehumidify the fresh air intake, and the other coil is for cooling circulated air. The deeply chilled water is necessary only for removing the moisture from the fresh air. The latter coil requires moderately cool water according to the HVAC load. Then 2 kinds of chilled water in terms of temperature should be prepared. The structure helps saving the energy consumption for air-conditioning because the higher chilled water temperature implies the better chiller efficiency (COP: Coefficient of Performance). In addition, an advanced control method that is called an ‘Air-Water cooperation system’ is introduced. The control system mainly focuses on energy savings through changing the temperature of the chilled water and supply air according to the HVAC load and weather conditions. In this paper, we introduce a Next Generation HVAC system with its control system and present evaluation results of the system for the model-building simulator.

  3. Towards Autonomous Control of HVAC Systems

    DEFF Research Database (Denmark)

    Brath, P.

    This thesis considered development of an autonomous control system for heating ventilation and air conditioning applications. By including auto-tuning, adaptation, diagnosis and supervision functions in the control system used in the HVAC industry will move the control of HVAC systems towards...... autonomous control. Together with better tuned controllers and more dedicated control it would be possible to decrease the energy consumption, save money and increase the indoor air climate. A flexible HVAC test system was designed and implemented. Standard components and sensors were used in the design...

  4. HVAC control system for building automation

    Energy Technology Data Exchange (ETDEWEB)

    Park, J. S.; Song, I. T.; Cho, S. W.; Cho, J. H. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-11-01

    The purpose of the project is to design and construction of the HVAC control system for building automation. The HVAC control system can accomplish the function which are the optimum operation condition and operation time, and the operation pattern analysis. Also, this control system can effectively manage energy saving, building environment control, facilities safety monitoring etc. The HVAC control system consisted of the central control and monitoring system (CCMS) and the direct digital controller (DDC). 1) CCMS: -Main Compute -Graphic Board -Printer -Console Desk -Intercom. 2) DDC : -IMC-M (System Control Unit Main Module) -IMC-1,2,3,4(System Control Unit Module). Following this report will be used important data for the design, construction, operation and maintenance of the HVAC control system. 12 refs., 6 figs., 9 tabs. (Author)

  5. HVAC system simulation: use of condensed input data

    Energy Technology Data Exchange (ETDEWEB)

    Hanby, V.I.; Round, M. (Loughborough Univ. of Technology (United Kingdom))

    1992-01-01

    In many applications of HVAC system simulation, results are required over an extended time period. For example, long-term energy use predictions are frequently needed in a design context for comparison of alternative plant configurations and they are also necessary in plant optimisation studies where the objective function to be minimised contains energy-use terms. These are typical application areas which have involved the use of SPATS, a modular, steady-state HVAC plant simulation program developed at Loughborough University. The computation time involved in generating long-run performance figures has prompted an investigation of ways in which such results can be generated more quickly. SPATS was conceived and developed for performance simulation of HVAC systems at the design stage and although a dynamic zone model has recently been implemented, the main use of SPATS has been to examine the performance of mechanical systems and subsystems over a range of load conditions. (Author).

  6. Optimal Model-Based Control in HVAC Systems

    DEFF Research Database (Denmark)

    Komareji, Mohammad; Stoustrup, Jakob; Rasmussen, Henrik;

    2008-01-01

    This paper presents optimal model-based control of a heating, ventilating, and air-conditioning (HVAC) system. This HVAC system is made of two heat exchangers: an air-to-air heat exchanger (a rotary wheel heat recovery) and a water-to- air heat exchanger. First dynamic model of the HVAC system...

  7. Control of noise - systems for compact HVAC units

    DEFF Research Database (Denmark)

    Pedersen, Steffen; Møller, Henrik

    2012-01-01

    This paper discusses noise control systems for implementation in compact HVAC units. The control of low-frequency noise presents different problems than at higher frequencies. This is mainly related to the long wavelength, which means that passive solutions require a significant volume of space......, often not available in compact HVAC units. Active control can provide attenuation over a significant frequency range, including low frequencies, while requiring a more limited space. While the concept of active noise control is simple, a number of limitations in the acoustical, electrical and control...... systems affect the performance of implementations. The source pressure and the impedance of a centrifugal fan were measured, and a number of configurations for noise control were investigated. The performance of a simple analogue feedback control was tested in a physical prototype. An adaptive digital...

  8. Intelligent control of HVAC systems. Part I: Modeling and synthesis

    Directory of Open Access Journals (Sweden)

    Adrian TOADER

    2013-03-01

    Full Text Available This is the first part of a work on intelligent type control of Heating, Ventilating and Air-Conditioning (HVAC systems. The study is performed from the perspective of giving a unitary control method to ensure high energy efficiency and air quality improving. To illustrate the proposed HVAC control technique, in this first part it is considered as benchmark problem a single thermal space HVAC system. The construction of the mathematical model is performed only with a view to obtain a framework of HVAC intelligent control validation by numerical simulations. The latter will be reported in a second part of the study.

  9. Why, when and how do HVAC-systems pollute? Characterisation of HVAC-systems related pollution

    NARCIS (Netherlands)

    Bluyssen, P.M.; Björkroth, M.; Müller, B.; Oliveira Fernandes, E. de; Roulet, C.A.

    2000-01-01

    In the beginning of 1998 a three-year European project, AIRLESS, was started to develop strategies, principles and protocols to improve and control the performance of HVAC-systems and its components for incorporation in codes and guidelines. Twelve institutes, universities and companies from seven

  10. Maintenance of HVAC-systems and components: How to prevent pollution from HVAC-systems?

    NARCIS (Netherlands)

    Müller, B.; Björkroth, M.; Plitt, U.; Bluyssen, P.M.

    2000-01-01

    In the beginning of 1998 a three-year European project, AIRLESS, was started to develop strategies, principles and protocols to improve and control the performance of HVAC-systems and its components for incorporation in codes and guidelines. Twelve institutes, universities and companies, from seven

  11. [Air quality control systems: heating, ventilating, and air conditioning (HVAC)].

    Science.gov (United States)

    Bellucci Sessa, R; Riccio, G

    2004-01-01

    After a brief illustration of the principal layout schemes of Heating, Ventilating, and Air Conditioning (HVAC), the first part of this paper summarizes the standards, both voluntary and compulsory, regulating HVAC facilities design and installation with regard to the question of Indoor Air Quality (IAQ). The paper then examines the problem of ventilation systems maintenance and the essential hygienistic requirements in whose absence HVAC facilities may become a risk factor for people working or living in the building. Lastly, the paper deals with HVAC design strategies and methods, which aim not only to satisfy comfort and air quality requirements, but also to ensure easy and effective maintenance procedures.

  12. Design Concepts for Optimum Energy Use in HVAC Systems.

    Science.gov (United States)

    Electric Energy Association, New York, NY.

    Much of the innovative work in the design and application of heating, ventilating, and air conditioning (HVAC) systems is concentrated on improving the cost effectiveness of such systems through optimizing energy use. One approach to the problem is to reduce a building's HVAC energy demands by designing it for lower heat gains and losses in the…

  13. Optimal Set-Point Synthesis in HVAC Systems

    DEFF Research Database (Denmark)

    Komareji, Mohammad; Stoustrup, Jakob; Rasmussen, Henrik

    2007-01-01

    components, encompassing fans, primary/secondary pump, tertiary pump, and air-to-air heat exchanger wheel; and a fraction of thermal power used by the HVAC system. The goals that have to be achieved by the HVAC system appear as constraints in the optimization problem. To solve the optimization problem......This paper presents optimal set-point synthesis for a heating, ventilating, and air-conditioning (HVAC) system. This HVAC system is made of two heat exchangers: an air-to-air heat exchanger and a water-to-air heat exchanger. The objective function is composed of the electrical power for different......, a steady state model of the HVAC system is derived while different supplying hydronic circuits are studied for the water-to-air heat exchanger. Finally, the optimal set-points and the optimal supplying hydronic circuit are resulted....

  14. HVAC systems in a field laboratory for indoor climate study

    DEFF Research Database (Denmark)

    Fang, Lei; Melikov, Arsen Krikor; Olesen, Bjarne W.

    2012-01-01

    This paper presents the design of a HVAC system for a field lab. The design integrated mixing ventilation, displacement ventilation, low impulse vertical ventilation, personalized ventilation, natural ventilation, hybrid ventilation, active chilled beams, radiant ceiling and floor, and heat...

  15. Review of Residential Low-Load HVAC Systems

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Scott A.; Thornton, Brian; Widder, Sarah H.

    2013-09-01

    In support of the U.S. Department of Energy’s (DOE’s) Building America Program, Pacific Northwest National Laboratory (PNNL) conducted an investigation to inventory commercially available HVAC technologies that are being installed in low-load homes. The first step in this investigation was to conduct a review of published literature to identify low-load HVAC technologies available in the United States and abroad, and document the findings of existing case studies that have evaluated the performance of the identified technologies. This report presents the findings of the literature review, identifies gaps in the literature or technical understanding that must be addressed before low-load HVAC technologies can be fully evaluated, and introduces PNNL’s planned research and analysis for this project to address identified gaps and potential future work on residential low-load HVAC systems.

  16. [Analysis and research on cleaning points of HVAC systems in public places].

    Science.gov (United States)

    Yang, Jiaolan; Han, Xu; Chen, Dongqing; Jin, Xin; Dai, Zizhu

    2010-03-01

    To analyze cleaning points of HVAC systems, and to provides scientific base for regulating the cleaning of HVAC systems. Based on the survey results on the cleaning situation of HVAC systems around China for the past three years, we analyzes the cleaning points of HVAC systems from various aspects, such as the major health risk factors of HVAC systems, the formulation strategy of the cleaning of HVAC systems, cleaning methods and acceptance points of the air ducts and the parts of HVAC systems, the onsite protection and individual protection, the waste treatment and the cleaning of the removed equipment, inspection of the cleaning results, video record, and the final acceptance of the cleaning. The analysis of the major health risk factors of HVAC systems and the formulation strategy of the cleaning of HVAC systems is given. The specific methods for cleaning the air ducts, machine units, air ports, coil pipes and the water cooling towers of HVAC systems, the acceptance points of HVAC systems and the requirements of the report on the final acceptance of the cleaning of HVAC systems are proposed. By the analysis of the points of the cleaning of HVAC systems and proposal of corresponding measures, this study provides the base for the scientific and regular launch of the cleaning of HVAC systems, a novel technology service, and lays a foundation for the revision of the existing cleaning regulations, which may generate technical and social benefits to some extent.

  17. HVAC systems in shopping centers as a utility business

    Energy Technology Data Exchange (ETDEWEB)

    Wolfert, J.E.

    1985-01-01

    Retail spaces in shopping centers have been noted for their low-cost and medium-quality HVAC systems. Typically, these systems are installed with minimal engineering and provided with less maintenance. There are, however, methods of providing higher quality HVAC systems for these retail spaces. One method is for the developer to provide a central plant type system and redistribute HVAC services for these spaces. The central plant system can redistribute chilled water, heated water, chilled air, heated air, tower water, electricity, or any other readily transportable energy source. With central type services, the economics are such that the individual retailer experiences no more overall cost but receives the benefits of a higher quality system. The developer has a larger investment but receives a reasonable return on this additional investment. The utilities now service a building that has a lower demand and a higher load factor. And society as a whole is presented with a facility that is considerably more energy efficient.

  18. Energy-Efficient Building HVAC Control Using Hybrid System LBMPC

    CERN Document Server

    Aswani, Anil; Taneja, Jay; Krioukov, Andrew; Culler, David; Tomlin, Claire

    2012-01-01

    Improving the energy-efficiency of heating, ventilation, and air-conditioning (HVAC) systems has the potential to realize large economic and societal benefits. This paper concerns the system identification of a hybrid system model of a building-wide HVAC system and its subsequent control using a hybrid system formulation of learning-based model predictive control (LBMPC). Here, the learning refers to model updates to the hybrid system model that incorporate the heating effects due to occupancy, solar effects, outside air temperature (OAT), and equipment, in addition to integrator dynamics inherently present in low-level control. Though we make significant modeling simplifications, our corresponding controller that uses this model is able to experimentally achieve a large reduction in energy usage without any degradations in occupant comfort. It is in this way that we justify the modeling simplifications that we have made. We conclude by presenting results from experiments on our building HVAC testbed, which s...

  19. Hybrid HVAC systems with chemical dehumidification for supermarket applications

    Energy Technology Data Exchange (ETDEWEB)

    Capozzoli, Alfonso; Mazzei, Pietro; Minichiello, Francesco; Palma, Daniele [DETEC, University of Naples Federico II, P.le Tecchio, 80, 80125 Naples (Italy)

    2006-06-15

    HVAC systems in supermarkets must assure both thermal comfort for occupants and suitable climatic conditions for refrigerated cases, which operate better with low ambient relative humidity (40-45%). Since open display cases substantially reduce sensible load and moderately reduce latent load, ambient sensible/total heat load ratio is less than usual. Thus, if dehumidification is carried out with a traditional cooling coil, over-sizing of the coil and re-heating of the treated air are necessary, with energy and economic waste. To offset these disadvantages, hybrid HVAC systems with chemical dehumidification may be employed. In this paper a case study is presented in which a traditional HVAC system is compared to hybrid systems with chemical dehumidification. Dynamic simulation codes (DOE and DesiCalc{sup (}TM)) and test reference year data (TRY), opportunely elaborated, have been used. Annual operating costs have been estimated and large savings have been obtained with hybrid systems. Considerable reduction of electric energy demand as well as better control of thermal-hygrometric conditions were noted. A simple payback of about 1 year has been obtained. Finally, a virtual retrofitting operation on 30% of the existing HVAC systems in Italian supermarkets has shown significant operating cost savings. [Author].

  20. D0 HVAC System Controls Evaluation of Upgrade Options

    Energy Technology Data Exchange (ETDEWEB)

    Markley, D.; Simon, P.; /Fermilab

    1998-05-05

    This engineering note documents three different options for upgrading the Dzero HVAC control system. All three options leave the current field hardware and field devices intact and upgrade the computer control hardware and software. Dzero will be heading into a physics run starting in 2000. This physics run could last several years. The Dzero HVAC system is an integral part of climate control and electronics cooling. The current HVAC control system is based upon a 1985 Johnson Controls System. In order to enter the next long-term physics run with a solid HVAC control system, the current control system needs to be upgraded. This proposal investigates three options: (1) Replacement to the next generation of Johnson Controls Hardware and Software with the Johnson Controls operator interface - FESS; (2) Replacement to the next generation of Johnson Controls Hardware and Software with the FIX32 Operator Interface - FESS/Dzero; and (3) Replacement with a commercially available Programmable Logic Controller (PLC) WITH THE FIX 32 Operator Interface - Dzero.

  1. System solution to improve energy efficiency of HVAC systems

    Science.gov (United States)

    Chretien, L.; Becerra, R.; Salts, N. P.; Groll, E. A.

    2017-08-01

    According to recent surveys, heating and air conditioning systems account for over 45% of the total energy usage in US households. Three main types of HVAC systems are available to homeowners: (1) fixed-speed systems, where the compressor cycles on and off to match the cooling load; (2) multi-speed (typically, two-speed) systems, where the compressor can operate at multiple cooling capacities, leading to reduced cycling; and (3) variable-speed systems, where the compressor speed is adjusted to match the cooling load of the household, thereby providing higher efficiency and comfort levels through better temperature and humidity control. While energy consumption could reduce significantly by adopting variable-speed compressor systems, the market penetration has been limited to less than 10% of the total HVAC units and a vast majority of systems installed in new construction remains single speed. A few reasons may explain this phenomenon such as the complexity of the electronic circuitry required to vary compressor speed as well as the associated system cost. This paper outlines a system solution to boost the Seasonal Energy Efficiency Rating (SEER) of a traditional single-speed unit through using a low power electronic converter that allows the compressor to operate at multiple low capacity settings and is disabled at high compressor speeds.

  2. Power Flow Analysis of HVAC and HVDC Transmission Systems for Offshore WindParks

    DEFF Research Database (Denmark)

    da Silva, Filipe Miguel Faria; Castro, Rui

    2009-01-01

    , the two options are analysed from a power flow point of view. The influence in the voltage regulation of the onshore connection busbar is investigated in a 57 bus test power system. The simulation results obtained for each one of the above mentioned transmission system configurations allow the conclusion......As the onshore wind resource is running shorter, wind power promoters are paying attention to the offshore resources. As in most cases there is no load offshore, wind power must be transmitted to the main land. To do so, two options are available: HVAC and HVDC transmission systems. In this paper...... that HVAC solution is limited by the distance to shore and by the wind transmitted power. HVDC options do not show these limitations, but are more expensive and more delicate to deal with, because there is a lack of operational experience, so far....

  3. Decentralized Optimization for a Novel Control Structure of HVAC System

    Directory of Open Access Journals (Sweden)

    Shiqiang Wang

    2016-01-01

    Full Text Available A decentralized control structure is introduced into the heating, ventilation, and air conditioning (HVAC system to solve the high maintenance and labor cost problem in actual engineering. Based on this new control system, a decentralized optimization method is presented for sensor fault repair and optimal group control of HVAC equipment. Convergence property of the novel method is theoretically analyzed considering both convex and nonconvex systems with constraints. In this decentralized control system, traditional device is fitted with a control chip such that it becomes a smart device. The smart device can communicate and operate collaboratively with the other devices to accomplish some designated tasks. The effectiveness of the presented method is verified by simulations and hardware tests.

  4. [Sick building syndrome and HVAC system: MVOC from air filters].

    Science.gov (United States)

    Schleibinger, H W; Wurm, D; Möritz, M; Böck, R; Rüden, H

    1997-08-01

    Growth and emissions of volatile metabolites of microorganisms on air filters are suspected to contribute to health complaints in ventilated rooms. To prove the microbiological production of volatile organic compounds (MVOC), concentrations of aldehydes and ketones were determined in two large HVAC systems. The in situ derivated aldehydes and ketones (as 2,4-dinitrophenyl-hydrazones) were analysed by HPLC and UV detection. The detection limit of each compound was 1 ppb (margin of error HVAC systems. First results show that the compounds formaldehyde, acetaldehyde and acetone could be detected before and after the filters. The concentrations of these VOC after the filters were significantly increased--as a mean over twenty measurements--, especially as far as filters made of glass fibre are concerned. However the found concentrations were low and mostly comparable to outdoor findings. In simultaneous laboratory experiments pieces of used filter material of one HVAC system and unused filter pieces (for blank values) were examined in small incubation chambers to investigate the possible production of MVOC. For the incubation a temperature of 20 degrees C and a relative humidity of 95% was chosen. In these experiments an almost identical spectrum of compounds (formaldehyde and acetone) was found as in the field measurements. The concentrations of these compounds were higher in the chambers with the used filter pieces. The concentration of acetone ranged up to almost 12 mg/m3.--As our field experiments correspond with our laboratory experiments, we assume that the microbial production of volatile organic compounds in HVAC systems under operating conditions is possible.

  5. Neural network based optimal control of HVAC&R systems

    Science.gov (United States)

    Ning, Min

    Heating, Ventilation, Air-Conditioning and Refrigeration (HVAC&R) systems have wide applications in providing a desired indoor environment for different types of buildings. It is well acknowledged that 30%-40% of the total energy generated is consumed by buildings and HVAC&R systems alone account for more than 50% of the building energy consumption. Low operational efficiency especially under partial load conditions and poor control are part of reasons for such high energy consumption. To improve energy efficiency, HVAC&R systems should be properly operated to maintain a comfortable and healthy indoor environment under dynamic ambient and indoor conditions with the least energy consumption. This research focuses on the optimal operation of HVAC&R systems. The optimization problem is formulated and solved to find the optimal set points for the chilled water supply temperature, discharge air temperature and AHU (air handling unit) fan static pressure such that the indoor environment is maintained with the least chiller and fan energy consumption. To achieve this objective, a dynamic system model is developed first to simulate the system behavior under different control schemes and operating conditions. The system model is modular in structure, which includes a water-cooled vapor compression chiller model and a two-zone VAV system model. A fuzzy-set based extended transformation approach is then applied to investigate the uncertainties of this model caused by uncertain parameters and the sensitivities of the control inputs with respect to the interested model outputs. A multi-layer feed forward neural network is constructed and trained in unsupervised mode to minimize the cost function which is comprised of overall energy cost and penalty cost when one or more constraints are violated. After training, the network is implemented as a supervisory controller to compute the optimal settings for the system. In order to implement the optimal set points predicted by the

  6. Design And Prototype Testing Of Economizer In HVAC Systems

    Directory of Open Access Journals (Sweden)

    Kongara Ajay

    2014-05-01

    Full Text Available Power, the word itself says to what extent the world is dependent on it. It may be fortunate or unfortunate, we are totally dependent on the power which is making the usage higher and higher which left us with energy crises and increasing costs of the energy usage. It’s time for Energy saving. These days, number of people in favour of the Energy saving has been increasing not to lessen the cost of usage but to let our future generations live with light and luxury. In this project, I have worked on the Energy conservation measures for HVAC that will save the energy to a little higher extent by designing an economizer. The theme of the project is to design a energy efficient economizer for HVAC Systems. A single unit of energy saving will yield in generation of two units of energy. My concern is to conserve energy and reduce usage by using ECMs where ever required.

  7. Real-time supervision of building HVAC system performance

    Energy Technology Data Exchange (ETDEWEB)

    Djuric, Natasa

    2008-07-01

    This thesis presents techniques for improving building HVAC system performance in existing buildings generated using simulation-based tools and real data. Therefore, one of the aims has been to research the needs and possibilities to assess and improve building HVAC system performance. In addition, this thesis aims at an advanced utilization of building energy management system (BEMS) and the provision of useful information to building operators using simulation tools. Buildings are becoming more complex systems with many elements, while BEMS provide many data about the building systems. There are, however, many faults and issues in building performance, but there are legislative and cost-benefit forces induced by energy savings. Therefore, both BEMS and the computer-based tools have to be utilized more efficiently to improve building performance. The thesis consists of four main parts that can be read separately. The first part explains the term commissioning and the commissioning tool work principal based on literature reviews. The second part presents practical experiences and issues introduced through the work on this study. The third part deals with the computer-based tools application in design and operation. This part is divided into two chapters. The first deals with improvement in the design, and the second deals with the improvement in the control strategies. The last part of the thesis gives several rules for fault diagnosis developed using simulation tools. In addition, this part aims at the practical explanation of the faults in the building HVAC systems. The practical background for the thesis was obtained though two surveys. The first survey was carried out with the aim to find the commissioning targets in Norwegian building facilities. In that way, an overview of the most typical buildings, HVAC equipment, and their related problems was obtained. An on-site survey was carried out on an example building, which was beneficial for introducing the

  8. Filtration effectiveness of HVAC systems at near-roadway schools.

    Science.gov (United States)

    McCarthy, M C; Ludwig, J F; Brown, S G; Vaughn, D L; Roberts, P T

    2013-06-01

    Concern for the exposure of children attending schools located near busy roadways to toxic, traffic-related air pollutants has raised questions regarding the environmental benefits of advanced heating, ventilation, and air-conditioning (HVAC) filtration systems for near-road pollution. Levels of black carbon and gaseous pollutants were measured at three indoor classroom sites and at seven outdoor monitoring sites at Las Vegas schools. Initial HVAC filtration systems effected a 31-66% reduction in black carbon particle concentrations inside three schools compared with ambient air concentrations. After improved filtration systems were installed, black carbon particle concentrations were reduced by 74-97% inside three classrooms relative to ambient air concentrations. Average black carbon particle concentrations inside the schools with improved filtration systems were lower than typical ambient Las Vegas concentrations by 49-96%. Gaseous pollutants were higher indoors than outdoors. The higher indoor concentrations most likely originated at least partially from indoor sources, which were not targeted as part of this intervention. Recent literature has demonstrated adverse health effects in subjects exposed to ambient air near major roadways. Current smart growth planning and infill development often require that buildings such as schools are built near major roadways. Improving the filtration systems of a school's HVAC system was shown to decrease children's exposure to near-roadway diesel particulate matter. However, reducing exposure to the gas-phase air toxics, which primarily originated from indoor sources, may require multiple filter passes on recirculated air. © 2012 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  9. Value impact analysis of Generic Issue 143, Availability of Heating, Ventilation, Air Conditioning (HVAC) and Chilled Water Systems

    Energy Technology Data Exchange (ETDEWEB)

    Daling, P.M.; Marler, J.E.; Vo, T.V.; Phan, H.; Friley, J.R. [Pacific Northwest Lab., Richland, WA (United States)

    1993-11-01

    This study evaluates the values (benefits) and impacts (costs) associated with potential resolutions to Generic Issue 143, ``Availability of HVAC and Chilled Water Systems.`` The study identifies vulnerabilities related to failures of HVAC, chilled water, and room cooling systems; develops estimates of room heatup rates and safety-related equipment vulnerabilities following losses of HVAC/room cooler systems; develops estimates of the core damage frequencies and public risks associated with failures of these systems; develops three proposed resolution strategies to this generic issue; and performs a value/impact analysis of the proposed resolutions. Existing probabilistic risk assessments for four representative plants, including one plant from each vendor, form the basis for the core damage frequency and public risk calculations. Both internal and external events were considered. It was concluded that all three proposed resolution strategies exceed the $1,000/person-rem cost-effectiveness ratio. Additional evaluations were performed to develop ``generic`` insights on potential design-related and configuration-related vulnerabilities and potential high-frequency ({approximately}1E-04/RY) accident sequences that involve failures of HVAC/room cooling functions. It was concluded that, although high-frequency accident sequences may exist at some plants, these high-frequency sequences are plant-specific in nature or have been resolved through hardware and/or operational changes. The plant-specific Individual Plant Examinations are an effective vehicle for identification and resolution of these plant-specific anomalies and hardware configurations.

  10. Intelligent control of HVAC systems. Part II: perceptron performance analysis

    Directory of Open Access Journals (Sweden)

    Ioan URSU

    2013-09-01

    Full Text Available This is the second part of a paper on intelligent type control of Heating, Ventilating, and Air-Conditioning (HVAC systems. The whole study proposes a unified approach in the design of intelligent control for such systems, to ensure high energy efficiency and air quality improving. In the first part of the study it is considered as benchmark system a single thermal space HVAC system, for which it is assigned a mathematical model of the controlled system and a mathematical model(algorithm of intelligent control synthesis. The conception of the intelligent control is of switching type, between a simple neural network, a perceptron, which aims to decrease (optimize a cost index,and a fuzzy logic component, having supervisory antisaturating role for neuro-control. Based on numerical simulations, this Part II focuses on the analysis of system operation in the presence only ofthe neural control component. Working of the entire neuro-fuzzy system will be reported in a third part of the study.

  11. HVAC System Automatic Controls and Indoor Air Quality in Schools. Technical Bulletin.

    Science.gov (United States)

    Wheeler, Arthur E.

    Fans, motors, coils, and other control components enable a heating, ventilating, and air-conditioning (HVAC) system to function smoothly. An explanation of these control components and how they make school HVAC systems work is provided. Different systems may be compared by counting the number of controlled devices that are required. Control…

  12. HVAC System Automatic Controls and Indoor Air Quality in Schools. Technical Bulletin.

    Science.gov (United States)

    Wheeler, Arthur E.

    Fans, motors, coils, and other control components enable a heating, ventilating, and air-conditioning (HVAC) system to function smoothly. An explanation of these control components and how they make school HVAC systems work is provided. Different systems may be compared by counting the number of controlled devices that are required. Control…

  13. New Comparison of HVDC and HVAC Transmission system

    Directory of Open Access Journals (Sweden)

    Vahid Behravesh

    2012-06-01

    Full Text Available Alternating current (AC is the main driving force in the industries and residential areas, but for the long transmission line (more than 400 miles AC transmission is more expensive than that of direct current (DC. Technically, AC transmission line control is more complicated because of the frequency. DC transmission does not have these limitations, which has led to build long HVDC transmission lines over the last 40 years. HVDC technology made possible to transfer bulk power over long distances. This paper presents a comparative evaluation of HVDC and HVAC transmission systems .

  14. New HVAC control by system identification

    Energy Technology Data Exchange (ETDEWEB)

    So, A.T.P.; Chan, W.L.; Chow, T.T.; Tse, W.L. [City University of Hong Kong, Kowloon (Hong Kong)

    1995-12-01

    Modern air-conditioning systems for commercial buildings commonly employ the concept of a ``Central All-Air System`` and the VAV system in particular is widely used in Hong Kong, and other places around the world for energy conservation. In the lengthy wet summer season of Hong Kong centralised air-handling units (AHUs) dehumidify and cool down the appropriate mixture of return air and outdoor fresh air to feed a ducting network to various Variable Air Volume Boxes. A good controller for the AHUs is extremely desirable from both human comfort and energy saving points of view. In this paper, a simulation model for a practical air-handling system is presented. Its behaviour under a conventional system of PID controllers is studied. A new controller based on system identification is developed where input and actuating variables are incorporated into a system identification model which can predict the new system status based on past records and suggest the optimal control actions. Computer simulation has proved that such a system identification based controller is superior to the conventional PID controller from at least the following three aspects: adaptation to system change, response rate and energy conservation. (author)

  15. Protecting HVAC systems from bio-terrorism.

    Science.gov (United States)

    Arterburn, Tom

    2003-01-01

    The FBI, in the wake of the September 11 attacks, issued an advisory to state and local law enforcement authorities and the public asking to remain especially alert to any unusual activities around ventilation systems. It noted that while the Bureau possessed no specific threats regarding the release of toxic chemicals into air handling systems, building owners and managers should be well-aware of the potential for contamination of such systems. This article presents recommendations of air-handling experts and associations for operators to consider.

  16. Flexible HVAC System for Lab or Classroom.

    Science.gov (United States)

    Friedan, Jonathan

    2001-01-01

    Discusses an effort to design a heating, ventilation, and air conditioning system flexible enough to accommodate an easy conversion of classrooms to laboratories and dry labs to wet labs. The design's energy efficiency and operations and maintenance are examined. (GR)

  17. Flexible HVAC System for Lab or Classroom.

    Science.gov (United States)

    Friedan, Jonathan

    2001-01-01

    Discusses an effort to design a heating, ventilation, and air conditioning system flexible enough to accommodate an easy conversion of classrooms to laboratories and dry labs to wet labs. The design's energy efficiency and operations and maintenance are examined. (GR)

  18. Thermal Components Boost Performance of HVAC Systems

    Science.gov (United States)

    2012-01-01

    As the International Space Station (ISS) travels 17,500 miles per hour, normal is having a constant sensation of free-falling. Normal is no rain, but an extreme amount of shine.with temperatures reaching 250 F when facing the Sun. Thanks to a number of advanced control systems onboard the ISS, however, the interior of the station remains a cool, comfortable, normal environment where astronauts can live and work for extended periods of time. There are two main control systems on the ISS that make it possible for humans to survive in space: the Thermal Control System (TCS) and the Environmental Control and Life Support system. These intricate assemblies work together to supply water and oxygen, regulate temperature and pressure, maintain air quality, and manage waste. Through artificial means, these systems create a habitable environment for the space station s crew. The TCS constantly works to regulate the temperature not only for astronauts, but for the critical instruments and machines inside the spacecraft as well. To do its job, the TCS encompasses several components and systems both inside and outside of the ISS. Inside the spacecraft, a liquid heat-exchange process mechanically pumps fluids in closed-loop circuits to collect, transport, and reject heat. Outside the ISS, an external system circulates anhydrous ammonia to transport heat and cool equipment, and radiators release the heat into space. Over the years, NASA has worked with a variety of partners.public and private, national and international. to develop and refine the most complex thermal control systems ever built for spacecraft, including the one on the ISS.

  19. Wireless Demand Response Controls for HVAC Systems

    Energy Technology Data Exchange (ETDEWEB)

    Federspiel, Clifford

    2009-06-30

    The objectives of this scoping study were to develop and test control software and wireless hardware that could enable closed-loop, zone-temperature-based demand response in buildings that have either pneumatic controls or legacy digital controls that cannot be used as part of a demand response automation system. We designed a SOAP client that is compatible with the Demand Response Automation Server (DRAS) being used by the IOUs in California for their CPP program, design the DR control software, investigated the use of cellular routers for connecting to the DRAS, and tested the wireless DR system with an emulator running a calibrated model of a working building. The results show that the wireless DR system can shed approximately 1.5 Watts per design CFM on the design day in a hot, inland climate in California while keeping temperatures within the limits of ASHRAE Standard 55: Thermal Environmental Conditions for Human Occupancy.

  20. Considerations to Prevent Growth and Spread of Legionella in HVAC Systems.

    Science.gov (United States)

    Coleman, Jeff

    1998-01-01

    Discusses the threat posed by the Legionnaire's Disease bacterium and the germ's ability to thrive in heating, ventilating, and air conditioning (HVAC) systems, especially in standing water. Describes ways to minimize disease risk through HVAC system design (such as locating cooling towers away from air intakes) and ways to maintain a clean…

  1. Air Cleaning Devices for HVAC Supply Systems in Schools. Technical Bulletin.

    Science.gov (United States)

    Wheeler, Arthur E.

    Guidelines for maintaining indoor air quality in schools with HVAC air cleaning systems are provided in this document. Information is offered on the importance of air cleaning, sources of air contaminants and indoor pollutants, types of air cleaners and particulate filters used in central HVAC systems, vapor and gas removal, and performance…

  2. Considerations to Prevent Growth and Spread of Legionella in HVAC Systems.

    Science.gov (United States)

    Coleman, Jeff

    1998-01-01

    Discusses the threat posed by the Legionnaire's Disease bacterium and the germ's ability to thrive in heating, ventilating, and air conditioning (HVAC) systems, especially in standing water. Describes ways to minimize disease risk through HVAC system design (such as locating cooling towers away from air intakes) and ways to maintain a clean…

  3. Theoretical analysis of HVAC duct hanger systems

    Science.gov (United States)

    Miller, R. D.

    1987-01-01

    Several methods are presented which, together, may be used in the analysis of duct hanger systems over a wide range of frequencies. The finite element method (FEM) and component mode synthesis (CMS) method are used for low- to mid-frequency range computations and have been shown to yield reasonably close results. The statistical energy analysis (SEA) method yields predictions which agree with the CMS results for the 800 to 1000 Hz range provided that a sufficient number of modes participate. The CMS approach has been shown to yield valuable insight into the mid-frequency range of the analysis. It has been demonstrated that it is possible to conduct an analysis of a duct/hanger system in a cost-effective way for a wide frequency range, using several methods which overlap for several frequency bands.

  4. Modeling and Measurement Constraints in Fault Diagnostics for HVAC Systems

    Energy Technology Data Exchange (ETDEWEB)

    Najafi, Massieh; Auslander, David M.; Bartlett, Peter L.; Haves, Philip; Sohn, Michael D.

    2010-05-30

    Many studies have shown that energy savings of five to fifteen percent are achievable in commercial buildings by detecting and correcting building faults, and optimizing building control systems. However, in spite of good progress in developing tools for determining HVAC diagnostics, methods to detect faults in HVAC systems are still generally undeveloped. Most approaches use numerical filtering or parameter estimation methods to compare data from energy meters and building sensors to predictions from mathematical or statistical models. They are effective when models are relatively accurate and data contain few errors. In this paper, we address the case where models are imperfect and data are variable, uncertain, and can contain error. We apply a Bayesian updating approach that is systematic in managing and accounting for most forms of model and data errors. The proposed method uses both knowledge of first principle modeling and empirical results to analyze the system performance within the boundaries defined by practical constraints. We demonstrate the approach by detecting faults in commercial building air handling units. We find that the limitations that exist in air handling unit diagnostics due to practical constraints can generally be effectively addressed through the proposed approach.

  5. Case study field evaluation of a systems approach to retrofitting a residential HVAC system

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain S.; McWiliams, Jennifer A.; Konopacki, Steven J.

    2003-09-01

    This case study focusing on a residence in northern California was undertaken as a demonstration of the potential of a systems approach to HVAC retrofits. The systems approach means that other retrofits that can affect the HVAC system are also considered. For example, added building envelope insulation reduces building loads so that smaller capacity HVAC system can be used. Secondly, we wanted to examine the practical issues and interactions with contractors and code officials required to accomplish the systems approach because it represents a departure from current practice. We identified problems in the processes of communication and installation of the retrofit that led to compromises in the final energy efficiency of the HVAC system. These issues must be overcome in order for HVAC retrofits to deliver the increased performance that they promise. The experience gained in this case study was used to optimize best practices guidelines for contractors (Walker 2003) that include building diagnostics and checklists as tools to assist in ensuring the energy efficiency of ''house as a system'' HVAC retrofits. The best practices guidelines proved to be an excellent tool for evaluating the eight existing homes in this study, and we received positive feedback from many potential users who reviewed and used them. In addition, we were able to substantially improve the energy efficiency of the retrofitted case study house by adding envelope insulation, a more efficient furnace and air conditioner, an economizer and by reducing duct leakage.

  6. Case study field evaluation of a systems approach to retrofitting a residential HVAC system

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain S.; McWiliams, Jennifer A.; Konopacki, Steven J.

    2003-09-01

    This case study focusing on a residence in northern California was undertaken as a demonstration of the potential of a systems approach to HVAC retrofits. The systems approach means that other retrofits that can affect the HVAC system are also considered. For example, added building envelope insulation reduces building loads so that smaller capacity HVAC system can be used. Secondly, we wanted to examine the practical issues and interactions with contractors and code officials required to accomplish the systems approach because it represents a departure from current practice. We identified problems in the processes of communication and installation of the retrofit that led to compromises in the final energy efficiency of the HVAC system. These issues must be overcome in order for HVAC retrofits to deliver the increased performance that they promise. The experience gained in this case study was used to optimize best practices guidelines for contractors (Walker 2003) that include building diagnostics and checklists as tools to assist in ensuring the energy efficiency of ''house as a system'' HVAC retrofits. The best practices guidelines proved to be an excellent tool for evaluating the eight existing homes in this study, and we received positive feedback from many potential users who reviewed and used them. In addition, we were able to substantially improve the energy efficiency of the retrofitted case study house by adding envelope insulation, a more efficient furnace and air conditioner, an economizer and by reducing duct leakage.

  7. Airside HVAC BESTEST: HVAC Air-Distribution System Model Test Cases for ASHRAE Standard 140

    Energy Technology Data Exchange (ETDEWEB)

    Judkoff, Ronald [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Neymark, Joel [J. Neymark & Associates; Kennedy, Mike D. [Mike D. Kennedy, Inc.; Gall, J. [AAON, Inc.; Henninger, R. [GARD Analytics, Inc.; Hong, T. [Lawrence Berkeley National Laboratory; Knebel, D. [AAON, Inc.; McDowell, T. [Thermal Energy System Specialists, LLC; Witte, M. [GARD Analytics, Inc.

    2017-08-07

    This paper summarizes recent work to develop new airside HVAC equipment model analytical verification test cases for ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. The analytical verification test method allows comparison of simulation results from a wide variety of building energy simulation programs with quasi-analytical solutions, further described below. Standard 140 is widely cited for evaluating software for use with performance-path energy efficiency analysis, in conjunction with well-known energy-efficiency standards including ASHRAE Standard 90.1, the International Energy Conservation Code, and other international standards. Airside HVAC Equipment is a common area of modelling not previously explicitly tested by Standard 140. Integration of the completed test suite into Standard 140 is in progress.

  8. Real-time supervision of building HVAC system performance

    Energy Technology Data Exchange (ETDEWEB)

    Djuric, Natasa

    2008-07-01

    This thesis presents techniques for improving building HVAC system performance in existing buildings generated using simulation-based tools and real data. Therefore, one of the aims has been to research the needs and possibilities to assess and improve building HVAC system performance. In addition, this thesis aims at an advanced utilization of building energy management system (BEMS) and the provision of useful information to building operators using simulation tools. Buildings are becoming more complex systems with many elements, while BEMS provide many data about the building systems. There are, however, many faults and issues in building performance, but there are legislative and cost-benefit forces induced by energy savings. Therefore, both BEMS and the computer-based tools have to be utilized more efficiently to improve building performance. The thesis consists of four main parts that can be read separately. The first part explains the term commissioning and the commissioning tool work principal based on literature reviews. The second part presents practical experiences and issues introduced through the work on this study. The third part deals with the computer-based tools application in design and operation. This part is divided into two chapters. The first deals with improvement in the design, and the second deals with the improvement in the control strategies. The last part of the thesis gives several rules for fault diagnosis developed using simulation tools. In addition, this part aims at the practical explanation of the faults in the building HVAC systems. The practical background for the thesis was obtained though two surveys. The first survey was carried out with the aim to find the commissioning targets in Norwegian building facilities. In that way, an overview of the most typical buildings, HVAC equipment, and their related problems was obtained. An on-site survey was carried out on an example building, which was beneficial for introducing the

  9. T.A.B. of HVAC System in IMEF

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Sang Youl; Choo, Y. S.; Choung, W. M.; You, K. S.; Hong, K. P

    2005-12-15

    T.A.B of the HVAC system in IMEF is that the adjustment for satisfying the design requirement is done through the review of documents related to the its design and the measurement using the apparatus. Doing T.A.B., the comfortable indoor environments and the negative pressure among the areas is remained, and the air flows to the more contaminated area. T.A.B. is an abbreviation of Testing, Adjusting and Balancing. In this job, a quantitative judgment of each equipments' performance, a proper adjustment of the volume of airflow and water in terminal equipment and a proportional distribution of flow rate in the distribution system(main duct, branch duct and terminal) based on design values have been performed. After finishing these procedures, the system is inspected and adjusted so that all air conditioning system in IMEF building performs its best capacity as mentioned in design requirements.

  10. Parametric analysis of air–water heat recovery concept applied to HVAC systems: Effect of mass flow rates

    Directory of Open Access Journals (Sweden)

    Mohamad Ramadan

    2015-09-01

    Full Text Available In the last three decades, the world has experienced enormous increases in energy and fuel consumption as a consequence of the economic and population growth. This causes renewable energy and energy recovery to become a requirement in building designs rather than option. The present work concerns a coupling between energy recovery and Heating, Ventilating and Air Conditioning HVAC domains and aims to apply heat recovery concepts to HVAC applications working on refrigeration cycles. It particularly uses the waste energy of the condenser hot air to heat/preheat domestic water. The heat exchanger considered in the recovery system is concentric tube heat exchanger. A thermal modeling of the complete system as well as a corresponding iterative code are developed and presented. Calculations with the code are performed and give pertinent magnitude orders of energy saving and management in HVAC applications. A parametric analysis based on several water and air flow rates is carried out. It was shown that water can be heated from 25 to 70 °C depending on the mass flow rates and cooling loads of the HVAC system. The most efficient configurations are obtained by lowering the air flow rate of the condenser fan.

  11. Co-simulation of innovative integrated HVAC systems in buildings

    Energy Technology Data Exchange (ETDEWEB)

    Trcka, Marija; Hensena, Jan L.M.; Wetter, Michael

    2010-06-21

    Integrated performance simulation of buildings HVAC systems can help in reducing energy consumption and increasing occupant comfort. However, no single building performance simulation (BPS) tool offers sufficient capabilities and flexibilities to analyze integrated building systems and to enable rapid prototyping of innovative building and system technologies. One way to alleviate this problem is to use co-simulation, as an integrated approach to simulation. This article elaborates on issues important for co-simulation realization and discusses multiple possibilities to justify the particular approach implemented in the here described co-simulation prototype. The prototype is validated with the results obtained from the traditional simulation approach. It is further used in a proof-of-concept case study to demonstrate the applicability of the method and to highlight its benefits. Stability and accuracy of different coupling strategies are analyzed to give a guideline for the required coupling time step.

  12. RELIABILITY ANALYSIS OF THE ELECTRICAL POWER DISTRIBUTION SYSTEM TO SELECTED PORTIONS OF THE NUCLEAR HVAC SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    N. Ramirez

    2004-12-16

    A design requirement probability of 0.01 or less in a 4-hour period ensures that the nuclear heating, ventilation, and air-conditioning (HVAC) system in the primary confinement areas of the Dry Transfer Facilities (DTFs) and Fuel Handling Facility (FHF) is working during a Category 1 drop event involving commercial spent nuclear fuel (CSNF) assemblies (BSC 2004a , Section 5.1.1.48). This corresponds to an hourly HVAC failure rate of 2.5E-3 per hour or less, which is contributed to by two dominant causes: equipment failure and loss of electrical power. Meeting this minimum threshold ensures that a Category 1 initiating event followed by the failure of HVAC is a Category 2 event sequence. The two causes for the loss of electrical power include the loss of offsite power and the loss of onsite power distribution. Thus, in order to meet the threshold requirement aforementioned, the failure rate of mechanical equipment, loss of offsite power, and loss of onsite power distribution must be less than or equal to 2.5E-3 per hour for the nuclear HVAC system in the primary confinement areas of the DTFs and FHF. The loss of offsite power occurs at a frequency of 1.1E-5 per hour (BSC 2004a, Section 5.1.1.48). The purpose of this analysis is to determine the probability of occurrence of the unavailability of the nuclear HVAC system in the primary confinement areas of the DTFs and FHF due to loss of electrical power. In addition, this analysis provides insights on the contribution to the unavailability of the HVAC system due to equipment failure. The scope of this analysis is limited to finding the frequency of loss of electrical power to the nuclear HVAC system in the primary confinement areas of the DTFs and FHF.

  13. Space HVAC systems - a manual. Vol. 3. Constructional elements. Handbuch der Klimatechnik. Bd. 3. Bauelemente

    Energy Technology Data Exchange (ETDEWEB)

    1988-01-01

    Vol. 3 of this series describes the design, function and fundamentals of calculation of air conditioning system elements and gives hints on their fields of application. Subjects: Heat transfer media; air moisturizers and dehumidifiers and their application in HVAC systems; refrigerators; air filters; ducts and auxiliary elements; fans; air conditioners; measuring methods and equipment for HVAC systems; fire protection and mechanical smoke prevention; clean room technology. (HWJ).

  14. Tools for Evaluating Fault Detection and Diagnostic Methods for HVAC Secondary Systems

    Science.gov (United States)

    Pourarian, Shokouh

    through glazing and the study of zone model is conducted in this direction to modify the existing zone model. In this research project, the following tasks are completed and summarized in this report: 1. Develop dynamic simulation models in the HVACSIM+ environment for common fan coil unit and dual duct system configurations. The developed simulation models are able to produce both fault-free and faulty operational data under a wide variety of faults and severity levels for advanced control, operation, and AFDD technology development and evaluation purposes; 2. Develop a model structure, which includes the grouping of blocks and superblocks, treatment of state variables, initial and boundary conditions, and selection of equation solver, that can simulate a dual duct system efficiently with satisfactory stability; 3. Design and conduct a comprehensive and systematic validation procedure using collected experimental data to validate the developed simulation models under both fault-free and faulty operational conditions; 4. Conduct a numerical study to compare two solution techniques: Powell's Hybrid (PH) and Levenberg-Marquardt (LM) in terms of their robustness and accuracy. 5. Modification of the thermal state of the existing building zone model in HVACSIM+ library of component. This component is revised to consider the transmitted heat through glazing as a heat source for transient building zone load prediction In this report, literature, including existing HVAC dynamic modeling environment and models, HVAC model validation methodologies, and fault modeling and validation methodologies, are reviewed. The overall methodologies used for fault free and fault model development and validation are introduced. Detailed model development and validation results for the two secondary systems, i.e., fan coil unit and dual duct system are summarized. Experimental data mostly from the Iowa Energy Center Energy Resource Station are used to validate the models developed in this project

  15. Determination of k-factors of HVAC system components using measurement and CFD modelling

    OpenAIRE

    Smith, Shaun J.

    1998-01-01

    This thesis conforms conventional and advanced experimental techniques for the measurement of and mathematical prediction of velocity pressure-loss factors (kfactors) for fittings used in heating, ventilation and air-conditioning (HVAC) systems. After an extensive study of different tracer-gas experimental techniques, the constant injection method is applied to various duct fittings on a small scale HVAC system situated in a laboratory. The results are compared with those of experiments perfo...

  16. Small Business Voucher CRADA Report: Natural Gas Powered HVAC System for Commercial and Residential Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Betts, Daniel [Be Power Tech, Deerfield Beach, FL (United States); Ally, Moonis Raza [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Mudiraj, Shyam [Be Power Tech, Deerfield Beach, FL (United States); Tilghman, Matthew [Be Power Tech, Deerfield Beach, FL (United States); Graham, Matthew [Be Power Tech, Deerfield Beach, FL (United States)

    2017-04-30

    Be Power Tech is commercializing BeCool, the first integrated electricity-producing heating, ventilation, and air conditioning (HVAC) system using a non-vapor compression cycle (VCC), packaged rooftop HVAC unit that also produces base-load electricity, heating, ventilation, and air conditioning. BeCool is a distributed energy resource with energy storage that eliminates the tremendous peak electricity demand associated with commonly used electricity-powered vapor compression air conditioning systems.

  17. Fault ride-through and grid support of permanent magnet synchronous generator-based wind farms with HVAC and VSC-HVDC transmission systems

    DEFF Research Database (Denmark)

    Liu, Hongzhi; Chen, Zhe

    2012-01-01

    This paper describes fault ride-through and grid support of offshore wind farms based on permanent magnet synchronous generator (PMSG) wind turbines connected to the onshore AC network through two alternative transmission systems: high voltage AC (HVAC) or high voltage DC (HVDC) based on voltage...... source converters (VSC). The proposed configurations of the PMSG-based offshore wind farm and VSC-based HVDC are given as well as their control strategies under both steady state and fault state. The PMSG-based offshore wind farm is integrated into a test power transmission system via either HVAC or VSC-HVDC...

  18. Comparative Analysis of HVAC System Based on Life Cycle Cost Analysis

    Directory of Open Access Journals (Sweden)

    Jignesh M. Barot

    2014-07-01

    Full Text Available A heating, ventilating, and air conditioning (HVAC system is designed to satisfy the environmental requirements of comfort or a process, in a specific building or portion of a building and in a particular geographic locale. Efficient design of heating, ventilating and air-conditioning (HVAC systems is a primary concern in building projects. The objectives of the HVAC system design are to provide a thermal comfort, good indoor quality and energy conservation. For the typical commercial building projects, it is not difficult to acquire the reference settings for efficient operation. However, for some special projects, due to the specific design and control of the HVAC system, conventional settings may not be necessarily energy-efficient in daily operation. The HVAC system design and equipment selection for a commercial building (376 TR is included as a case study in this paper. The outcomes of this paper are efficient design of HVAC system with minimum energy consumption and equipment selection based on operating and life cycle cost analysis.

  19. Comparative Energy and Cost Analysis Between Conventional HVAC Systems and Geothermal Heat Pump Systems

    Science.gov (United States)

    2007-11-02

    heat pump (GSHP) relative to conventional heating ventilation and air conditioning (HVAC) systems: air-source heat pumps (ASHP), air-cooled air conditioning with either natural gas, fuel oil, or liquid petroleum gas furnaces, or with electrical resistance heating. The Monte Carlo simulation is performed for a standard commercial office building within each of the 48 continental states. Regardless of the conventional HVAC system chosen, the simulation shows that for each state the GSHP has the highest probability of using less energy and having a lower operating and life

  20. Energy Savings Potential of Flexible and Adaptive HVAC Distribution Systems for Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Loftness, Vivian; Brahme, Rohini; Mondazzi, Michelle; Vineyard, Edward; MacDonald, Michael

    2002-06-01

    It has been understood by architects and engineers that office buildings with easily re-configurable space and flexible mechanical and electrical systems are able to provide comfort that increases worker productivity while using less energy. Raised floors are an example of how fresh air, thermal conditioning, lighting needs, and network access can be delivered in a flexible manner that is not ''embedded'' within the structure. What are not yet documented is how well these systems perform and how much energy they can save. This area is being investigated in phased projects of the 21st Century Research Program of the Air-conditioning and Refrigeration Technology Institute. For the initial project, research teams at the Center for Building Performance and Diagnostics, Pittsburgh, Pennsylvania, and Oak Ridge National Laboratory, Oak Ridge, Tennessee, documented the diversity, performance, and incidence of flexible and adaptive HVAC systems. Information was gathered worldwide from journal and conference articles, case studies, manufactured products and assemblies, and interviews with design professionals. Their report thoroughly describes the variety of system types along with the various design alternatives observed for plenums, diffusers, individual control, and system integration. Many of the systems are illustrated in the report and the authors provide quantitative and qualitative comparisons. Among conclusions regarding key design issues, and barriers to widespread adoption, the authors state that flexible and adaptive HVAC systems, such as underfloor air, perform as well if not better than ceiling-based systems. Leading engineers have become active proponents after their first experience, which is resulting in these flexible and adaptive HVAC systems approaching 10 percent of the new construction market. To encourage adoption of this technology that improves thermal comfort and indoor air quality, follow-on work is required to further document

  1. Design and Implementation of Energy Efficiency in HVAC Systems Based on Robust PID Control for Industrial Applications

    OpenAIRE

    Muharrem Imal

    2015-01-01

    Energy efficiency in heating, ventilating, and air-conditioning (HVAC) systems is a primary concern in process projects, since the energy consumption has the highest percentage in HVAC for all processes. Without sacrifice of thermal comfort, to reset the suitable operating parameters, such as the humidity and air temperature, would have energy saving with immediate effect. In this paper, the simulation-optimization approach described the effective energy efficiency for HVAC systems which are ...

  2. HLT configuration management system

    CERN Document Server

    Daponte, Vincenzo

    2015-01-01

    The CMS High Level Trigger (HLT) is implemented running a streamlined version of the CMS offline reconstruction software running on thousands of CPUs. The CMS software is written mostly in C++, using Python as its configuration language through an embedded CPython interpreter. The configuration of each process is made up of hundreds of modules, organized in sequences and paths. As an example, the HLT configurations used for 2011 data taking comprised over 2200 different modules, organized in more than 400 independent trigger paths. The complexity of the HLT configurations and the large number of configuration produced require the design of a suitable data management system. The present work describes the designed solution to manage the considerable number of configurations developed and to assist the editing of new configurations. The system is required to be remotely accessible and OS-independent as well as easly maintainable easy to use. To meet these requirements a three-layers architecture has been choose...

  3. Review on the HVAC System Modeling Types and the Shortcomings of Their Application

    Directory of Open Access Journals (Sweden)

    Raad Z. Homod

    2013-01-01

    Full Text Available The modeling of the heating, ventilation, and air conditioning (HVAC system is a prominent topic because of its relationship with energy savings and environmental, economical, and technological issues. The modeling of the HVAC system is concerned with the indoor thermal sensation, which is related to the modeling of building, air handling unit (AHU equipments, and indoor thermal processes. Until now, many HVAC system modeling approaches are made available, and the techniques have become quite mature. But there are some shortcomings in application and integration methods for the different types of the HVAC model. The application and integration processes will act to accumulate the defective characteristics for both AHU equipments and building models such as nonlinear, pure lag time, high thermal inertia, uncertain disturbance factors, large-scale systems, and constraints. This paper shows types of the HVAC model and the advantages and disadvantages for each application of them, and it finds out that the gray-box type is the best one to represent the indoor thermal comfort. But its application fails at the integration method where its response deviated to unreal behavior.

  4. Selecting HVAC Systems for Schools To Balance the Needs for Indoor Air Quality, Energy Conservation and Maintenance. Technical Bulletin.

    Science.gov (United States)

    Wheeler, Arthur E.; Kunz, Walter S., Jr.

    Although poor air quality in a school can have multiple causes, the heating, ventilating, and air-conditioning (HVAC) system plays a major role. Suggestions that architects, facilities managers, school board members, and administrators can use in selecting HVAC systems are discussed. Focus is on the performance criteria for classroom systems, and…

  5. Selecting HVAC Systems for Schools To Balance the Needs for Indoor Air Quality, Energy Conservation and Maintenance. Technical Bulletin.

    Science.gov (United States)

    Wheeler, Arthur E.; Kunz, Walter S., Jr.

    Although poor air quality in a school can have multiple causes, the heating, ventilating, and air-conditioning (HVAC) system plays a major role. Suggestions that architects, facilities managers, school board members, and administrators can use in selecting HVAC systems are discussed. Focus is on the performance criteria for classroom systems, and…

  6. HVAC cable systems with forced water cooling for wind energy transmission

    Energy Technology Data Exchange (ETDEWEB)

    Brakelmann, Heinrich; Zhang, Dongping [Duisburg-Essen Univ., Duisburg (DE). Dept. Energy Transport and Storage (ETS)

    2008-07-01

    This paper presents a solution for an efficient wind energy transmission onshore: HVAC cable system with forced water cooling, which provides a substantial increase of the cable ampacity without any modification of the cable construction and design. This work shows the projecting and planning of such HVAC cable systems in combination with a cooling system, especially considering the faulty (n-1)-case. The efficiency utilizing the short-term load capacity of the cable systems transmitting wind energy is shown by computations provided by specialized and adapted FEM (Finite Element Method) software. (orig.)

  7. Plutonium Finishing Plant (PFP) HVAC System Component Index

    Energy Technology Data Exchange (ETDEWEB)

    DIAZ, E.N.; DICK, J.D.

    2000-07-26

    This document lists safety class (SC) and safety significant (SS) components for the Heating Ventilation Air Conditioning (HVAC) and specifies the critical characteristics for Commercial Grade Items (CGI), as required by HNF-PRO-268 and HNF-PRO-1819. These are the minimum specifications that the equipment must meet in order to properly perform its safety function. There may be several manufacturers or models that meet the critical characteristics for any one item.

  8. Integrated high efficiency blower apparatus for HVAC systems

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xiaoyue; Weigman, Herman; Wang, Shixiao

    2007-07-24

    An integrated centrifugal blower wheel for a heating, ventilation and air conditioning (HVAC) blower unit includes a first blade support, a second blade support, and a plurality of S-shaped blades disposed between the first and second blade supports, wherein each of the S-shaped blades has a trailing edge bent in a forward direction with respect to a defined direction of rotation of the wheel.

  9. Integrated high efficiency blower apparatus for HVAC systems

    Science.gov (United States)

    Liu, Xiaoyue; Weigman, Herman; Wang, Shixiao

    2007-07-24

    An integrated centrifugal blower wheel for a heating, ventilation and air conditioning (HVAC) blower unit includes a first blade support, a second blade support, and a plurality of S-shaped blades disposed between the first and second blade supports, wherein each of the S-shaped blades has a trailing edge bent in a forward direction with respect to a defined direction of rotation of the wheel.

  10. RADON MITIGATION IN SCHOOLS: HVAC SYTEMS IN SCHOOLS TEND TO HAVE A GREATER IMPACT ON RADON LEVELS THAN HVAC SYSTEMS IN HOMES

    Science.gov (United States)

    The first part of this two-part paper discusses radon entry into schools, radon mitigation approaches for schools, and school characteristics (e.g., heating, ventilation, and air conditioing -- HVAC-- system design and operationg) that influence radon entry and mitigation system ...

  11. RADON MITIGATION IN SCHOOLS: HVAC SYTEMS IN SCHOOLS TEND TO HAVE A GREATER IMPACT ON RADON LEVELS THAN HVAC SYSTEMS IN HOMES

    Science.gov (United States)

    The first part of this two-part paper discusses radon entry into schools, radon mitigation approaches for schools, and school characteristics (e.g., heating, ventilation, and air conditioing -- HVAC-- system design and operationg) that influence radon entry and mitigation system ...

  12. Predictive functional control based on fuzzy T-S model for HVAC systems temperature control

    Institute of Scientific and Technical Information of China (English)

    Hongli L(U); Lei JIA; Shulan KONG; Zhaosheng ZHANG

    2007-01-01

    In heating,ventilating and air-conditioning(HVAC)systems,there exist severe nonlinearity,time-varying nature,disturbances and uncertainties.A new predictive functional control based on Takagi-Sugeno(T-S)fuzzy model was proposed to control HVAC systems.The T-S fuzzy model of stabilized controlled process was obtained using the least squares method,then on the basis of global linear predictive model from T-S fuzzy model,the process was controlled by the predictive functional controller.Especially the feedback regulation part was developed to compensate uncertainties of fuzzy predictive model.Finally simulation test results in HVAC systems control applications showed that the proposed fuzzy model predictive functional control improves tracking effect and robustness.Compared with the conventional PID controller,this control strategy has the advantages of less overshoot and shorter setting time,etc.

  13. Fungal colonization of air filters for use in heating, ventilating, and air conditioning (HVAC) systems.

    Science.gov (United States)

    Simmons, R B; Crow, S A

    1995-01-01

    New and used cellulosic air filters for HVAC systems including those treated with antimicrobials were suspended in vessels with a range of relative humidities (55-99%) and containing non-sterile potting soil which stimulates fungal growth. Most filters yielded fungi prior to suspension in the chambers but only two of 14 nontreated filters demonstrated fungal colonization following use in HVAC systems. Filters treated with antimicrobials, particularly a phosphated amine complex, demonstrated markedly less fungal colonization than nontreated filters. In comparison with nontreated cellulosic filters, fungal colonization of antimicrobial-treated cellulosic filters was selective and delayed.

  14. Ontology for Life-Cycle Modeling of Heating, Ventilating, and Air Conditioning (HVAC) Systems: Experimental Applications Using Revit

    Science.gov (United States)

    2012-03-01

    Center, Construction Engineering Research Laboratory (ERDC-CERL) has developed a core life- cycle building information model ( BIM ) based on three...was to promote consistency and quality of content created for Building Information Models ( BIMs ) across various disciplines. The HVAC MVD was...MVD. 15. SUBJECT TERMS building information modeling ( BIM ), ontology, Army facilities, heating, ventilating, and air-conditioning (HVAC) systems

  15. Power Flow Analysis of HVAC and HVDC Transmission Systems for Offshore WindParks

    DEFF Research Database (Denmark)

    da Silva, Filipe Miguel Faria; Castro, Rui

    2009-01-01

    As the onshore wind resource is running shorter, wind power promoters are paying attention to the offshore resources. As in most cases there is no load offshore, wind power must be transmitted to the main land. To do so, two options are available: HVAC and HVDC transmission systems. In this paper...... that HVAC solution is limited by the distance to shore and by the wind transmitted power. HVDC options do not show these limitations, but are more expensive and more delicate to deal with, because there is a lack of operational experience, so far....

  16. Ultraviolet germicidal irradiation inactivation of airborne fungal spores and bacteria in upper-room air and HVAC in-duct configurations

    Energy Technology Data Exchange (ETDEWEB)

    Kujundzic, E.; Hernandez, M. [Colorado Univ., Boulder, CO (United States). Dept. of Civil, Environmental and Architectural Engineering; Miller, S.L. [Colorado Univ., Boulder, CO (United States). Dept. of Mechanical Engineering

    2007-01-15

    This article presented an evaluation of the efficiency of ultraviolet germicidal irradiation (UVGI) for inactivating airborne fungal spores and bacterial vegetative cells under 3 configurations, namely intrinsic, upper-room air, and in-duct. Several experiments were conducted in a pilot-scale chamber fitted with 4 corner ultraviolet lamps that irradiated the entire chamber; a full-scale room fitted with a UVGI system that irradiated the top 30 cm of the room; and, the supply air duct of a heating ventilation and air-conditioning (HVAC) system. Fungal spores and vegetative cells of bacterium were aerosolized regularly such that their numbers and physiologic state were comparable both with and without the UVGI lamps operating. The article provided information on the materials and methods used including the experimental facilities (pilot-scale chamber, full-scale room, and in-duct UVGI system and ductwork) as well as the methods used for the three experimental studies. It also discussed the bioaerosol generation and sampling and quantification. These included culturing and direct microscopy. UV fluence rate was described. Last, the the results, discussion and conclusions from the studies were presented. It was shown that increasing the air stream velocity through the supply air duct reduces the residence time of bioaerosol being exposed to in-duct UVGI. 36 refs., 3 figs.

  17. 'Consolidation' of HVAC and cooling systems at CERN

    CERN Document Server

    Inigo-Golfin, J; Pepinster, P; CERN. Geneva. TS Department

    2008-01-01

    A â€ワconsolidation” of installations after they have reached the end of their predetermined life-time is part of the life cycle of industrial installations, regardless how well maintained they are. The â€ワconsolidation” plan might cover the replacement of obsolete equipment, partial refurbishment, the work requested to comply with new standards and applicable rules (environmental aspects) until the complete replacement of the whole installation. This â€ワconsolidation” process is all the more critical since the installation dates of the existing cooling and HVAC equipment at CERN spans over a period of 50 years and â€ワconsolidation” in the past has been not been systematic, being most of the time associated with new projects. This paper describes the reasons behind the recent â€ワconsolidation” requests for cooling and HVAC equipment both for the accelerators backbone and in tertiary buildings. A criticality analysis is given, based on the criteria laid down in the p...

  18. AIRLESS, a European project on HVAC systems: Project programme and current status

    NARCIS (Netherlands)

    Bluyssen, P.M.; Björkroth, M.; Müller, B.; Oliveira Fernandes, E. de; Clausen, G.H.; Molina, J.L.; Roulet, C.A.

    1999-01-01

    In the beginning of 1998 a three year European project, AIRLESS, was started to develop strategies, principles and protocols to improve and control the performance of HVAC-systems and its components for incorporation in codes and guidelines. Twelve institutes, universities and companies from seven E

  19. Application of black-box models to HVAC systems for fault detection

    NARCIS (Netherlands)

    Peitsman, H.C.; Bakker, V.E.

    1996-01-01

    This paper describes the application of black-box models for fault detection and diagnosis (FDD) in heating, ventilat-ing, and air-conditioning (HVAC) systems. In this study, mul-tiple-input/single-output (MISO) ARX models and artificial neural network (ANN) models are used. The ARX models are exami

  20. Assessment of microbiological indoor air quality in an Italian office building equipped with an HVAC system.

    Science.gov (United States)

    Bonetta, Sa; Bonetta, Si; Mosso, S; Sampò, S; Carraro, E

    2010-02-01

    The purpose of this study was to evaluate the level and composition of bacteria and fungi in the indoor air of an Italian office building equipped with a heating, ventilation and air conditioning (HVAC) system. Airborne bacteria and fungi were collected in three open-space offices during different seasons. The microbial levels in the outdoor air, supply air diffusers, fan coil air flow and air treatment unit humidification water tank were used to evaluate the influence of the HVAC system on indoor air quality (IAQ). A medium-low level of bacterial contamination (50-500 CFU/m(3)) was found in indoor air. Staphylococcus and Micrococcus were the most commonly found genera, probably due to human presence. A high fungal concentration was measured due to a flood that occurred during the winter. The indoor seasonal distribution of fungal genera was related to the fungal outdoor distribution. Significant seasonal and daily variation in airborne microorganisms was found, underlining a relationship with the frequency of HVAC system switching on/off. The results of this monitoring highlight the role of the HVAC system on IAQ and could be useful to better characterise bacterial and fungal population in the indoor air of office buildings.

  1. Application of black-box models to HVAC systems for fault detection

    NARCIS (Netherlands)

    Peitsman, H.C.; Bakker, V.E.

    1996-01-01

    This paper describes the application of black-box models for fault detection and diagnosis (FDD) in heating, ventilat-ing, and air-conditioning (HVAC) systems. In this study, mul-tiple-input/single-output (MISO) ARX models and artificial neural network (ANN) models are used. The ARX models are

  2. Towards a framework for selection of supervisory control for commercial buildings: HVAC system energy efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Ramachandran, Thiagarajan; Kundu, Soumya; Chen, Yan; Vrabie, Draguna L.

    2017-07-03

    This paper develops and utilizes an optimization based framework to investigate the maximal energy efficiency potentially attainable by HVAC system operation in a non-predictive context. Performance is evaluated relative to the existing state of the art set-point reset strategies. The expected efficiency increase driven by operation constraints relaxations is evaluated.

  3. AIRLESS, a European project on HVAC systems: Project programme and current status

    NARCIS (Netherlands)

    Bluyssen, P.M.; Björkroth, M.; Müller, B.; Oliveira Fernandes, E. de; Clausen, G.H.; Molina, J.L.; Roulet, C.A.

    1999-01-01

    In the beginning of 1998 a three year European project, AIRLESS, was started to develop strategies, principles and protocols to improve and control the performance of HVAC-systems and its components for incorporation in codes and guidelines. Twelve institutes, universities and companies from seven

  4. Analysis on energy saving potential of integrated supermarket HVAC and refrigeration systems using multiple subcoolers

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Liang [Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240 (China); China R and D Center, Carrier Corporation, No. 3239 Shen Jiang Road, Shanghai 201206 (China); Zhang, Chun-Lu [China R and D Center, Carrier Corporation, No. 3239 Shen Jiang Road, Shanghai 201206 (China)

    2010-02-15

    The paper presents a model-based analysis on the energy saving potential of supermarket HVAC (heating, ventilating, and air-conditioning) and refrigeration systems using multiple subcoolers among the high-temperature HVAC system, the medium-temperature refrigeration system, and the low-temperature refrigeration system. The principle of energy reduction is to have the higher COP (coefficient of performance) system generate more cooling capacity to increase the cooling capacity or reduce the power consumption of the lower COP system. The subcooler could be placed between the medium-temperature and low-temperature systems, between the high-temperature and medium-temperature systems, and between the high-temperature and low-temperature systems. All integration scenarios of adding one, two and three subcoolers have been investigated. The energy saving potential varies with the load ratio between high-, medium- and low-temperature systems, COP of three systems, and the ''on-off'' duty time of HVAC system. The optimal sequence of adding subcoolers is also proposed. (author)

  5. Portable refrigerant charge meter and method for determining the actual refrigerant charge in HVAC systems

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Zhiming; Abdelaziz, Omar; LaClair, Tim L.

    2017-08-08

    A refrigerant charge meter and a method for determining the actual refrigerant charge in HVAC systems are described. The meter includes means for determining an optimum refrigerant charge from system subcooling and system component parameters. The meter also includes means for determining the ratio of the actual refrigerant charge to the optimum refrigerant charge. Finally, the meter includes means for determining the actual refrigerant charge from the optimum refrigerant charge and the ratio of the actual refrigerant charge to the optimum refrigerant charge.

  6. Control of Variable-Speed Pressurization Fan for an Offshore HVAC System

    DEFF Research Database (Denmark)

    Yang, Zhenyu; Pedersen, Simon; Løhndorf, Petar Durdevic

    2014-01-01

    of the inlet channel in the considered Heating Ventilation and Air-Condition (HVAC) system, or the pressurization system located inside the inlet channel, or both of them in a coordinated way. A Model-Predictive Control (MPC) solution to control the inlet throttle has been proposed in our previous work....... This paper proposes a set of control solutions to regulate the variablespeed pressurization fan system such that the energy efficiency of the considered HVAC system can be explicitly considered. A combined feed-forward with a PI-based feedback control solution, and a MPC solution are proposed based...... on derived simple system models. Some preliminary simulation results exhibit that both control solutions can keep the indoor pressure and the air circulation in a very satisfactory and robust manner, even subject to the presence of severe disturbances....

  7. Comparative guide to emerging diagnostic tools for large commercial HVAC systems

    Energy Technology Data Exchange (ETDEWEB)

    Friedman, Hannah; Piette, Mary Ann

    2001-05-01

    This guide compares emerging diagnostic software tools that aid detection and diagnosis of operational problems for large HVAC systems. We have evaluated six tools for use with energy management control system (EMCS) or other monitoring data. The diagnostic tools summarize relevant performance metrics, display plots for manual analysis, and perform automated diagnostic procedures. Our comparative analysis presents nine summary tables with supporting explanatory text and includes sample diagnostic screens for each tool.

  8. Saving electricity in HVAC systems. Elektrizitaet sparen in Heizungs-, Lueftungs-, Klima- und Kaelteanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Hochstrasser, W.

    1993-03-01

    The SIA initiated the recommendation SIA 380/4, ''Electrical energy in building construction'' which contains information on energy conservation. As an example, the field of HVAC systems is discussed. In this field, electrical energy is required especially for the following applications: Blower drives, refrigerating compressor drives, hot and cold water pumps, oil and gas burners, control systems, air heaters, and electric moisturizers. Energy-saving alternatives are presented in each case. (orig.)

  9. Simulation of the full and part load energy consumption of HVAC system of building

    Energy Technology Data Exchange (ETDEWEB)

    Samuel, A.E.; Chia, T.H.

    1983-01-01

    A model based on dynamic heat transfers through the building envelope and between the contents inside the building is developed. This model has been incorporated into the Computer Aided Building Airconditioning Requirement and Environmental Temperature Simulation (CABARETS) program. The model takes into account the interaction between the external excitation, building envelope, contents inside the building, air handling systems and the mechanical equipment. An iterative numerical procedure has been implemented to solve the simultaneous heat transfer equations for the various components of the system. The indoor temperature and humidity variations with or without the operation of the HVAC system are established, and the energy requirements for maintaining the controlled environment are computed. The electrical power requirement for operating the HVAC mechanical equipment is estimated by the model, and the values are compared with the observed electricity consumption for the mechanical services.

  10. COMPARATIVE STUDY AMONG HYBRID GROUND SOURCE HEAT PUMP SYSTEM, COMPLETE GROUND SOURCE HEAT PUMP AND CONVENTIONAL HVAC SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Jiang Zhu; Yong X. Tao

    2011-11-01

    In this paper, a hotel with hybrid geothermal heat pump system (HyGSHP) in the Pensacola is selected and simulated by the transient simulation software package TRNSYS [1]. To verify the simulation results, the validations are conducted by using the monthly average entering water temperature, monthly facility consumption data, and etc. And three types of HVAC systems are compared based on the same building model and HVAC system capacity. The results are presented to show the advantages and disadvantages of HyGSHP compared with the other two systems in terms of energy consumptions, life cycle cost analysis.

  11. Study of active noise control system for a commercial HVAC unit

    Science.gov (United States)

    Devineni, Naga

    Acoustic noise is a common problem in everyday life. If the appliances that are present in the work and living areas generate noise then it's a serious problem. One such appliance is the Heating, Ventilation and Air-conditioning system (HVAC) in which blower fan and compressor units are housed together. Operation of a HVAC system creates two kinds of noise. One is the noise due to the air flow and the other is the result of the compressor. Both of them exhibit different signal properties and need different strategies to control them. There has been previous efforts in designing noise control systems that can control noise from the HVAC system. These include passive methods which use sound absorption materials to attenuate noise and active methods which cancel noise by generating anti-noise. Passive methods are effective in limiting the high frequency noise, but are inefficient in controlling low frequency noise from the compressor. Compressor noise is one of the strong low frequency components that propagate through the walls, therefore there is need for deploying active signal processing methods that consider the signal properties into consideration to cancel the noise acoustically. The quasi periodic nature of the compressor noise is exploited in noise modeling which aids in implementing an adaptive linear prediction filter in estimating the anti noise [12]. In this thesis, a multi channel architecture has been studied for a specific HVAC system in order to improve noise cancellation by creating larger quiet zone. In addition to the multi-channel architecture, a real time narrow band Active Noise Control (ANC) was employed to cancel noise under practical conditions.

  12. Changes in airborne fungi from the outdoors to indoor air; large HVAC systems in nonproblem buildings in two different climates.

    Science.gov (United States)

    Kemp, P C; Neumeister-Kemp, H G; Esposito, B; Lysek, G; Murray, F

    2003-01-01

    Little is known about the changes in occurrence and distribution of airborne fungi as they are transported in the airstream from the outdoor air through the heating, ventilation, and air conditioning (HVAC) system to the indoor air. To better understand this, airborne fungi were analyzed in the HVAC systems of two large office buildings in different climate zones. Fungal samples were taken in each of the walk-in chambers of the HVAC systems using a six-stage Andersen Sampler with malt extract agar. Results showed that fungal species changed with different locations in the HVAC systems. The outdoor air intake produced the greatest filtration effect for both the counts and species of outdoor air fungi. The colony forming unit (CFU) counts and species diversity was further reduced in the air directly after the filters. The cooling coils also had a substantial filtration effect. However, in room air the CFU counts were double and the mixture of fungal species was different from the air leaving the HVAC system at the supply air outlet in most locations. Diffusion of outdoor air fungi to the indoors did not explain the changes in the mixture of airborne fungi from the outdoor air to the indoor air, and some of the fungi present in the indoor air did not appear to be transported indoors by the HVAC systems.

  13. System Configuration Management Implementation Procedure for the Canister Storage Building (CSB)

    Energy Technology Data Exchange (ETDEWEB)

    GARRISON, R.C.

    2000-11-28

    This document provides configuration management for the Distributed Control System (DCS), the Gaseous Effluent Monitoring System (GEMS-100) System, the Heating Ventilation and Air Conditioning (HVAC) Programmable Logic Controller (PLC), the Canister Receiving Crane (CRC) CRN-001 PLC, and both North and South vestibule door interlock system PLCs at the Canister Storage Building (CSB). This procedure identifies and defines software configuration items in the CSB control and monitoring systems, and defines configuration control throughout the system life cycle. Components of this control include: configuration status accounting; physical protection and control; and verification of the completeness and correctness of these items.

  14. Commissioning of building HVAC systems for improvement of energy performance; Commissioning of building HVAC systems for improvement of energy performance. Teilnahme IEA-ECBCS Annex 40 (Betreiberkompetenz)

    Energy Technology Data Exchange (ETDEWEB)

    Chuard, J.-M.

    2005-06-15

    This paper takes a look at the tasks performed in Task 40 of the 'Energy Conservation in Buildings and Community Systems ECBCS' programme of the International Energy Agency IEA that is taking a look at the commissioning of building HVAC systems with the aim of improving the energy performance of such systems. Emphasis is put on the Swiss contribution to the task. This well-illustrated paper presents information on the structure of the task, time-lines and a diagram for its implementation structures. Also, the countries participating in Task 40 and their representatives are listed, and various work already published by the annex is noted. The paper places a focus on operator competence and lists points to be taken into account when carrying out work on optimising energy consumption. The various processes involved are noted and discussed. Management guidelines are presented and economical and market aspects are discussed. Finally, projects that will continue the work are noted.

  15. HVAC DDC控制系统的能量管理研究%Study of Energy Management Functions in DDC System for HVAC

    Institute of Scientific and Technical Information of China (English)

    郑萍; 张家川; 潘世永

    2000-01-01

    本文作者论述了HVAC的DDC控制方式及其控制与能量管理相结合的特点,并提出了几种能量管理程序,以及该程序的节能作用.%This paper describes the DDC for HVAC control system and the characteristics of the combination between control and energy management.It gives several energy management programs and analyzes the function of the progrmas in energy saving.

  16. A new pulse modulation adaptive controller (PMAC) applied to HVAC systems

    Energy Technology Data Exchange (ETDEWEB)

    Salsbury, T.I. [Johnson Controls Inc., Milwaukee (United States)

    2002-12-01

    The paper proposes a new switching control law (pulse modulation adaptive controller, PMAC) that implements pulse-width-pulse-frequency modulation. Pulse durations are determined to maintain the amplitude of variation in the controlled variable at or below a user-defined level. In addition to providing quantifiable control performance, PMAC can reduce component wear by issuing fewer switches than conventional control schemes. The control law is developed around a first-order system characterization but incorporates an adaptive loop, which allows application to a wide range of non-first-order and also time-variant systems. Test results are presented from applying PMAC to both simulated and real HVAC systems. (author)

  17. Power system technical performance issues related to the application of long HVAC cables

    DEFF Research Database (Denmark)

    Wiechowski, on behalf of Cigre WG C4.502, W.; Sluis, L. V. der; Ohno, Teruo

    2011-01-01

    This paper reports the progress of work of Cigre Working Group C4.502 “Power system technical performance issues related to the application of long HVAC cables”. The primary goal of the WG C4.502 is to write a technical brochure that will serve as practical guide for performing studies necessary...... for assessing the technical performance of HV/EHV systems with large share of AC cable lines. This paper besides providing a background for formulation of WG C4.502 and its overall aim, describes the tasks that were accomplished before the interim report was submitted to Study Committee C4 System Technical...

  18. Power System Technical Performance Issues related to the Application of Long HVAC Cables

    DEFF Research Database (Denmark)

    Wiechowski, W.; der Sluis, L.V.; Ohno, Teruo

    2011-01-01

    This paper reports the progress of work of Cigre Working Group C4.502 “Power system technical performance issues related to the application of long HVAC cables”. The primary goal of the WG C4.502 is to write a technical brochure that will serve as practical guide for performing studies necessary...... for assessing the technical performance of HV/EHV systems with large share of AC cable lines. This paper besides providing a background for formulation of WG C4.502 and its overall aim, describes the tasks that were accomplished before the interim report was submitted to Study Committee C4 System Technical...

  19. Evaluation of Heating, Ventilation, and Air conditioning (HVAC System Performance in an Administrative Building in Tehran (Iran

    Directory of Open Access Journals (Sweden)

    H. Mari Oriyad

    2014-09-01

    Full Text Available Introduction: One of the factors influencing on indoor air quality of the buildings is performance of HVAC (heating, ventilation, and air conditioning systems. These systems supply clean and odorless air, with temperature, humidity, and air velocity within comfort ranges for the residents. The aim of this study was to evaluate performance HVAC system in an administrative building in Tehran. .Material and Method: A questionnaire, developed in their research was used to assess the building occupants’ perception about the performance of HVAC system. To evaluate the performance of HVAC systems, air velocities were measured in the diffusers using a thermal anemometer. Moreover, CO2 concentration, air temperature and relative humidity were measured in the whole floors of the building. Air distribution inside the building was evaluated using smoke test. .Results: Most of the studied people complained about the direction of airflow, thermal conditions and cigarette odor. The highest level of carbon dioxide was measured at 930 ppm inside the restaurant. The maximum and minimum air temperatures and relative humidity were measured 28.3-13.8° C and 28.4-23% respectively. Smoke test showed that the air distribution/direction wasn’t suitable in one third of air diffusers. .Conclusion: Improper air distribution / direction was the main problem with the studied HVAC system which could be corrected by adjusting and balancing of the system.

  20. A Subspace Identification Method for Detecting Abnormal Behavior in HVAC Systems

    Directory of Open Access Journals (Sweden)

    Dimitris Sklavounos

    2015-01-01

    Full Text Available A method for the detection of abnormal behavior in HVAC systems is presented. The method combines deterministic subspace identification for each zone independently to create a system model that produces the anticipated zone’s temperature and the sequential test CUSUM algorithm to detect drifts of the rate of change of the difference between the real and the anticipated measurements. Simulation results regarding the detection of infiltration heat losses and the detection of exogenous heat gains such as fire demonstrate the effectiveness of the proposed method.

  1. Design and Implementation of Energy Efficiency in HVAC Systems Based on Robust PID Control for Industrial Applications

    Directory of Open Access Journals (Sweden)

    Muharrem Imal

    2015-01-01

    Full Text Available Energy efficiency in heating, ventilating, and air-conditioning (HVAC systems is a primary concern in process projects, since the energy consumption has the highest percentage in HVAC for all processes. Without sacrifice of thermal comfort, to reset the suitable operating parameters, such as the humidity and air temperature, would have energy saving with immediate effect. In this paper, the simulation-optimization approach described the effective energy efficiency for HVAC systems which are used in industrial process. Due to the complex relationship of the HVAC system parameters, it is necessary to suggest optimum settings for different operations in response to the dynamic cooling loads and changing weather conditions during a year. Proportional-integral-derivative (PID programming was developed which can effectively handle the discrete, nonlinear and highly constrained optimization problems. Energy efficiency process has been made by controlling of alternative current (AC drivers for ventilation and exhaust fans, according to supplied air flow capacity and differential air pressure between supplied and exhaust air. Supervisory controller software was developed by using programmable controllers and human machine interface (HMI units. The new designed HVAC control system would have a saving potential of about 40% as compared to the existing operational settings, without any extra cost.

  2. Energy fan power consumption comparison of subway station HVAC system

    Institute of Scientific and Technical Information of China (English)

    JIANGYong; ZHUYingxin

    2003-01-01

    Subway thermal environment control system is a mass energy consumed system. The fan operation is the Key of energy saving. Some feasible fan operation modes are proposed and compared in this paper from the view of energy and operation cost saving. It is concluded that VAV is the optimal operation mode for metro system with highest energy saving.

  3. A Comfort-Aware Energy Efficient HVAC System Based on the Subspace Identification Method

    Directory of Open Access Journals (Sweden)

    O. Tsakiridis

    2016-01-01

    Full Text Available A proactive heating method is presented aiming at reducing the energy consumption in a HVAC system while maintaining the thermal comfort of the occupants. The proposed technique fuses time predictions for the zones’ temperatures, based on a deterministic subspace identification method, and zones’ occupancy predictions, based on a mobility model, in a decision scheme that is capable of regulating the balance between the total energy consumed and the total discomfort cost. Simulation results for various occupation-mobility models demonstrate the efficiency of the proposed technique.

  4. Development of DMC controllers for temperature control of a room deploying the displacement ventilation HVAC system

    Directory of Open Access Journals (Sweden)

    Zhicheng Li, Ramesh K. Agarwal, Huijun Gao

    2013-01-01

    Full Text Available In this paper, by developing a new Dynamic Matrix Control (DMC method, we develop a controller for temperature control of a room cooled by a displacement ventilation HVAC system. The fluid flow and heat transfer inside the room are calculated by solving the Reynolds-Averaged Navier-Stokes (RANS equations including the effects of buoyancy in conjunction with a two-equation realizable k - epsilon turbulence model. Thus the physical environment is represented by a nonlinear system of partial differential equations. The system also has a large time delay because of the slowness of the heat exchange. The goal of the paper is to develop a controller that will maintain the temperature at three points near three different walls in a room within the specified upper and lower bounds. In order to solve this temperature control problem at three different points in the room, we develop a special DMC method. The results show that the newly developed DMC controller is an effective controller to maintain temperature within desired bounds at multiple points in the room and also saves energy when compared to other controllers. This DMC method can also be employed to develop controllers for other HVAC systems such as the overhead VAV (Variable Air Volume system and the radiant cooling hydronic system.

  5. Development of DMC controllers for temperature control of a room deploying the displacement ventilation HVAC system

    Energy Technology Data Exchange (ETDEWEB)

    Li, Zhicheng; Agarwal, Ramesh K. [Department of Mechanical Engineering and Materials Science, Washington University in Saint Louis, MO 63130 (United States); Gao, Huijun [Research Institute of Intelligent Control and Systems, Harbin Institute of Technology, Harbin 150001 (China)

    2013-07-01

    In this paper, by developing a new Dynamic Matrix Control (DMC) method, we develop a controller for temperature control of a room cooled by a displacement ventilation HVAC system. The fluid flow and heat transfer inside the room are calculated by solving the Reynolds-Averaged Navier-Stokes (RANS) equations including the effects of buoyancy in conjunction with a two-equation realizable k - epsilon turbulence model. Thus the physical environment is represented by a nonlinear system of partial differential equations. The system also has a large time delay because of the slowness of the heat exchange. The goal of the paper is to develop a controller that will maintain the temperature at three points near three different walls in a room within the specified upper and lower bounds. In order to solve this temperature control problem at three different points in the room, we develop a special DMC method. The results show that the newly developed DMC controller is an effective controller to maintain temperature within desired bounds at multiple points in the room and also saves energy when compared to other controllers. This DMC method can also be employed to develop controllers for other HVAC systems such as the overhead VAV (Variable Air Volume) system and the radiant cooling hydronic system.

  6. Modernisation of space HVAC systems with high energy consumption; Sanierung von RLT-Anlagen mit hohen Energieverbraeuchen

    Energy Technology Data Exchange (ETDEWEB)

    Willan, U. [ROM (Rud. Otto Meyer) - Technik fuer Mensch und Umwelt, Hamburg (Germany). Zentralbereich Ingenieurtechnik

    1997-12-31

    For office buildings and similarly used buildings, concepts are developed for the modernization of space hvac systems. The state of work in the following sectors is discussed: optimum comparison processes for space HVAC systems, measurements to assess the performance of alternative dehumidification and cooling systems, heat-physiological space model. (MSK) [Deutsch] Fuer Buerobauten und Gebaeude aehnlicher Nutzung werden Sanierungskonzepte fuer RLT-Anlagen erarbeitet. Im Folgenden wird der Stand der Arbeiten in den Bereichen: optimale Vergleichsprozesse fuer RLT-Anlagen, messtechnische Beurteilung alternativer Entfeuchtungs- und Kuehlsysteme sowie ein waermetechnisches Raummodell erlaeutert.

  7. Typology of Product Configuration Systems

    DEFF Research Database (Denmark)

    Jensen, Klaes Ladeby; Edwards, Kasper; Haug, Anders

    2007-01-01

    Many organisations are moving from mass production to mass customization. Product configuration systems (PCS) are increasingly seen as an interesting option for firms who wish to pursue a strategy with a high degree of product variance while retaining a low cost of specifying the product. To become...... more specific in relation to how product configuration systems can support mass customization, it is necessary to understand how different product configuration systems can be classified, and how these differ. This paper presents a typology of product configuration systems based on the five kinds...

  8. COMPREHENSIVE DIAGNOSTIC AND IMPROVEMENT TOOLS FOR HVAC-SYSTEM INSTALLATIONS IN LIGHT COMMERCIAL BUILDINGS

    Energy Technology Data Exchange (ETDEWEB)

    Abram Conant; Mark Modera; Joe Pira; John Proctor; Mike Gebbie

    2004-10-31

    Proctor Engineering Group, Ltd. (PEG) and Carrier-Aeroseal LLP performed an investigation of opportunities for improving air conditioning and heating system performance in existing light commercial buildings. Comprehensive diagnostic and improvement tools were created to address equipment performance parameters (including airflow, refrigerant charge, and economizer operation), duct-system performance (including duct leakage, zonal flows and thermal-energy delivery), and combustion appliance safety within these buildings. This investigation, sponsored by the National Energy Technology Laboratory, a division of the U.S. Department of Energy, involved collaboration between PEG and Aeroseal in order to refine three technologies previously developed for the residential market: (1) an aerosol-based duct sealing technology that allows the ducts to be sealed remotely (i.e., without removing the ceiling tiles), (2) a computer-driven diagnostic and improvement-tracking tool for residential duct installations, and (3) an integrated diagnosis verification and customer satisfaction system utilizing a combined computer/human expert system for HVAC performance. Prior to this work the aerosol-sealing technology was virtually untested in the light commercial sector--mostly because the savings potential and practicality of this or any other type of duct sealing had not been documented. Based upon the field experiences of PEG and Aeroseal, the overall product was tailored to suit the skill sets of typical HVAC-contractor personnel.

  9. Building Assessment Survey and Evaluation Study Summarized Data - HVAC Characteristics

    Science.gov (United States)

    In the Building Assessment Survey and Evaluation (BASE) Study Information on the characteristics of the heating, ventilation, and air conditioning (HVAC) system(s) in the entire BASE building including types of ventilation, equipment configurations, and operation and maintenance issues was acquired by examining the building plans, conducting a building walk-through, and speaking with the building owner, manager, and/or operator.

  10. 10 CFR 434.517 - HVAC systems and equipment.

    Science.gov (United States)

    2010-01-01

    ... zone Packaged terminal air conditioner with space heater or heat pump, one heating/cooling unit per... conditioner w/space heater (Note 8) Hot water (Note 8, 12) Hot water (Note 12) or electric resistance (Note B... and Reference Buildings 1,2 Building/space occupancy System No. (Table 517.4.1) Remarks (Table 517.4.1...

  11. Simulation Study of IMC and Fuzzy Controller for HVAC System

    Directory of Open Access Journals (Sweden)

    Umamaheshwari

    2009-06-01

    Full Text Available This paper presents how the fuzzy logic controller is used to solve the control problems of complex and non linear process and show that it is more robust and their performance are less sensitive to parametric variations than conventional controllers. These systems will yield a linear response when compared to ordinary controllers. The main advantage of Fuzzy control over conventional controllers is regulation can be done without over shoot.

  12. Modular VSC converter based HVDC power transmission from offshore wind power plant: Compared to the conventional HVAC system

    DEFF Research Database (Denmark)

    Sharma, Ranjan; Rasmussen, Tonny Wederberg; Jensen, Kim Høj;

    2010-01-01

    power transmission options with HVDC systems are under consideration. In this paper, a comparison between a conventional HVAC transmission system and a HVDC system equipped with modular voltage source converters is provided. The comparison is based on the total energy transmission capability...

  13. Integrated Heat Pump HVAC Systems for Near-Zero-Energy Homes - Business Case Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Van D [ORNL

    2007-05-01

    The long range strategic goal of the Department of Energy's Building Technologies (DOE/BT) Program is to create, by 2020, technologies and design approaches that enable the construction of net-zero energy homes at low incremental cost (DOE/BT 2005). A net zero energy home (NZEH) is a residential building with greatly reduced needs for energy through efficiency gains, with the balance of energy needs supplied by renewable technologies. While initially focused on new construction, these technologies and design approaches are intended to have application to buildings constructed before 2020 as well resulting in substantial reduction in energy use for all building types and ages. DOE/BT's Emerging Technologies (ET) team is working to support this strategic goal by identifying and developing advanced heating, ventilating, air-conditioning, and water heating (HVAC/WH) technology options applicable to NZEHs. Although the energy efficiency of heating, ventilating, and air-conditioning (HVAC) equipment has increased substantially in recent years, new approaches are needed to continue this trend. Dramatic efficiency improvements are necessary to enable progress toward the NZEH goals, and will require a radical rethinking of opportunities to improve system performance. The large reductions in HVAC energy consumption necessary to support the NZEH goals require a systems-oriented analysis approach that characterizes each element of energy consumption, identifies alternatives, and determines the most cost-effective combination of options. In particular, HVAC equipment must be developed that addresses the range of special needs of NZEH applications in the areas of reduced HVAC and water heating energy use, humidity control, ventilation, uniform comfort, and ease of zoning. In FY05 ORNL conducted an initial Stage 1 (Applied Research) scoping assessment of HVAC/WH systems options for future NZEHs to help DOE/BT identify and prioritize alternative approaches for further

  14. Preliminary CFD Analysis for HVAC System Design of a Containment Building

    Energy Technology Data Exchange (ETDEWEB)

    Son, Sung Man; Choi, Choengryul [ELSOLTEC, Yongin (Korea, Republic of); Choo, Jae Ho; Hong, Moonpyo; Kim, Hyungseok [KEPCO Engineering and Construction, Gimcheon (Korea, Republic of)

    2016-10-15

    HVAC (Heating, Ventilation, Air Conditioning) system has been mainly designed based on overall heat balance and averaging concepts, which is simple and useful for designing overall system. However, such a method has the disadvantage that cannot predict the local flow and temperature distributions in a containment building. In this study, a CFD (Computational Fluid Dynamics) preliminary analysis is carried out to obtain detailed flow and temperature distributions in a containment building and to ensure that such information can be obtained via CFD analysis. This approach can be useful for hydrogen analysis in an accident related to hydrogen released into a containment building. In this study, CFD preliminary analysis has been performed to obtain the detailed information of the reactor containment building by using the CFD analysis techniques and to ensure that such information can be obtained via CFD analysis. We confirmed that CFD analysis can offer enough detailed information about flow patterns and temperature field and that CFD technique is a useful tool for HVAC design of nuclear power plants.

  15. Energy efficient model based algorithm for control of building HVAC systems.

    Science.gov (United States)

    Kirubakaran, V; Sahu, Chinmay; Radhakrishnan, T K; Sivakumaran, N

    2015-11-01

    Energy efficient designs are receiving increasing attention in various fields of engineering. Heating ventilation and air conditioning (HVAC) control system designs involve improved energy usage with an acceptable relaxation in thermal comfort. In this paper, real time data from a building HVAC system provided by BuildingLAB is considered. A resistor-capacitor (RC) framework for representing thermal dynamics of the building is estimated using particle swarm optimization (PSO) algorithm. With objective costs as thermal comfort (deviation of room temperature from required temperature) and energy measure (Ecm) explicit MPC design for this building model is executed based on its state space representation of the supply water temperature (input)/room temperature (output) dynamics. The controllers are subjected to servo tracking and external disturbance (ambient temperature) is provided from the real time data during closed loop control. The control strategies are ported on a PIC32mx series microcontroller platform. The building model is implemented in MATLAB and hardware in loop (HIL) testing of the strategies is executed over a USB port. Results indicate that compared to traditional proportional integral (PI) controllers, the explicit MPC's improve both energy efficiency and thermal comfort significantly.

  16. Learning Based Bidding Strategy for HVAC Systems in Double Auction Retail Energy Markets

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Yannan; Somani, Abhishek; Carroll, Thomas E.

    2015-07-01

    In this paper, a bidding strategy is proposed using reinforcement learning for HVAC systems in a double auction market. The bidding strategy does not require a specific model-based representation of behavior, i.e., a functional form to translate indoor house temperatures into bid prices. The results from reinforcement learning based approach are compared with the HVAC bidding approach used in the AEP gridSMART® smart grid demonstration project and it is shown that the model-free (learning based) approach tracks well the results from the model-based behavior. Successful use of model-free approaches to represent device-level economic behavior may help develop similar approaches to represent behavior of more complex devices or groups of diverse devices, such as in a building. Distributed control requires an understanding of decision making processes of intelligent agents so that appropriate mechanisms may be developed to control and coordinate their responses, and model-free approaches to represent behavior will be extremely useful in that quest.

  17. Building HVAC control knowledge data schema – Towards a unified representation of control system knowledge

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yan; Treado, Stephen J.; Messner, John I.

    2016-12-01

    Building control systems for Heating, Ventilation, and Air Conditioning (HVAC) play a key role in realizing the functionality and operation of building systems and components. Building Control Knowledge (BCK) is the logic and algorithms embedded throughout building control system. There are different methods to represent the BCK. These methods differ in the selection of BCK representing elements and the format of those elements. There is a lack of standard data schema, for storing, retrieving, and reusing structured BCK. In this study, a modular data schema is created for BCK representation. The data schema contains eleven representing elements, i.e., control module name, operation mode, system schematic, control flow diagram, data point, alarm, parameter, control sequence, function, and programming code. Each element is defined with specific attributes. This data schema is evaluated through a case study demonstration. The demonstration shows a new way to represent the BCK with standard formats.

  18. The integrated engineering system for the HVAC branch. Annex; Das integrierte Ingenieursystem fuer die Haustechnikbranche; Anhang

    Energy Technology Data Exchange (ETDEWEB)

    Allenspach, J.; Duppenthaler, A.; Helbling, R.; Kohler, T.; Mantel, R.; Meineke, E. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1994-01-01

    In 1987, the intention of the former Swiss Federal Institute for Reactor Research was to initiate a transfer of know-how into practice by launching this project. The increasing need for software engineering tools by heating, ventilation and air conditioning (HVAC) companies demanded a new tool; to realise it, a joint venture project with private industry should concentrate the individual capabilities of each partner toward this goal. The present report describes the concept of the integrated engineering system, its user interface, the models, graphics, tools, multiuser operation and the system boundary. Results of field tests are presented together with information of the availability of the system. The annex contains the agreement for the usage of the public-domain-version of the system, experience reports of pilot clients and the end user`s and developer`s documentation. (author) figs., tabs., refs.

  19. A new HVAC system based on cogeneration by an i.c. engine

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R.M. [Istituto di Ingeneria Gestionale, Universita di Padova (Italy); Longo, G.A.; Romagnoni, P.C. [Istituto di Fisica Tecnica, Universita di Padova (Italy)

    1996-07-01

    A new HVAC system is proposed and studied. The plant is equipped with a reciprocating i.c. gas engine which produces electric energy with heat recovery from the jacket water heat and the exhaust. The electric energy serves the lighting and emf for the building and individual room reversible air-water heat pumps that mainly satisfy sensible cooling and a fraction of the winter heating load. An open-cycle absorption system, which treats the primary air, meets the summer latent load and year round ventilation requirements. In winter, the system operates as an open-cycle heat pump. The regeneration of the sorbent is obtained by the i.c. engine heat recovery. The proposed system is analysed by comparing its performance with a traditional plant, both in summer and winter mode. (Author)

  20. A new HVAC system based on cogeneration by an internal combustion engine

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R.M [Instituto di Ingegneria Gestionale, Universita di Padova, Vicenza (Italy); Longo, G.A.; Romagnoni, P.C. [Istituto di Fisica Technica, Universita di Padova, Padova (Italy)

    1997-06-01

    A new HVAC system is proposed and studied. The plant consists of a reciprocating internal combustion gas engine, producing electrical energy with heat recovery from the jacket water heat and the exhaust. The electricity serves lighting, emf for the building and individual room reversible air-water heat pumps that satisfy mainly sensible cooling and a fraction of the winter heating load. An open cycle absorption system which treats the primary air meets the summer latent load and year round ventilation requirements. In winter the system operates as an open cycle heat pump. The regeneration of the sorbent is obtained by the internal combustion engine heat recovery. The proposed system is analyzed comparing its performance with a traditional plant both in summer and winter mode. 8 refs.

  1. Strategy Guideline: HVAC Equipment Sizing

    Energy Technology Data Exchange (ETDEWEB)

    Burdick, A.

    2012-02-01

    The heating, ventilation, and air conditioning (HVAC) system is arguably the most complex system installed in a house and is a substantial component of the total house energy use. A right-sized HVAC system will provide the desired occupant comfort and will run efficiently. This Strategy Guideline discusses the information needed to initially select the equipment for a properly designed HVAC system. Right-sizing of an HVAC system involves the selection of equipment and the design of the air distribution system to meet the accurate predicted heating and cooling loads of the house. Right-sizing the HVAC system begins with an accurate understanding of the heating and cooling loads on a space; however, a full HVAC design involves more than just the load estimate calculation - the load calculation is the first step of the iterative HVAC design procedure. This guide describes the equipment selection of a split system air conditioner and furnace for an example house in Chicago, IL as well as a heat pump system for an example house in Orlando, Florida. The required heating and cooling load information for the two example houses was developed in the Department of Energy Building America Strategy Guideline: Accurate Heating and Cooling Load Calculations.

  2. Experimental investigation of cooling performance of a novel HVAC system combining natural ventilation with diffuse ceiling inlet and TABS

    DEFF Research Database (Denmark)

    Yu, Tao; Heiselberg, Per Kvols; Lei, Bo;

    2015-01-01

    Highlights •An experimental investigation of cooling performance of a combined HVAC system is carried out. •Cooling performance of TABS with and without the influence of diffuse ceiling is analyzed. •Radiant and convective heat transfer coefficients of TABS cooling are studied. •Cooling components...

  3. A Study on the Application of UV Sterilization Method in HVAC System

    Energy Technology Data Exchange (ETDEWEB)

    Cho, S. W.; Park, J. S.; Seo, I. W.; Lim, K. R.; An, W. S.; Oh, S. H.; Lee, K. W.; Kim, J. G.; Kwon, S. J

    2005-04-15

    The objective of this report is to study on the application of UV sterilization method on HVAC system in building. One type of commercial UV lamp was utilized during this research. It was 1,050 mm length, 24.5 mm diameter, 65 w lamp output, single ended lamp intended for insertion into al frame from inside. Twenty six lamps were mounted and operated in cross flow. They were allowed to operate for at least 30 minutes prior to beginning each test. The test rig was operated at 2.5 m/s and 20 .deg. C, and the relatively humidity 21.6 %RH. The effect of UV sterilization are investigated that as the general virus about 94 %, the mold microbe about 64 % and the bacillus about 86 %, respectively. Following this report will be used important data for the design and manufacture of the UV.

  4. Product Configuration Systems and Productivity

    DEFF Research Database (Denmark)

    Pedersen, Jørgen Lindgaard; Edwards, Kasper

    2004-01-01

    Twelve companies have been interviewed with the purpose to get information about technical, economic and organisational matters in respect of Product Configuration Systems (PCS).Combinations of qualitative interviews and quantitative scoring have been used in ranking expected and realized results...... from implementing PCS. The three highest aggregated scoring expected benefits are: 1)improved quality in specifications, 2)lower turnaround time, 3)less resource intensity.......Twelve companies have been interviewed with the purpose to get information about technical, economic and organisational matters in respect of Product Configuration Systems (PCS).Combinations of qualitative interviews and quantitative scoring have been used in ranking expected and realized results...

  5. Simulative Study into the Development of a Hybrid HVDC System Through a Comparative Research with HVAC: a Futuristic Approach

    Directory of Open Access Journals (Sweden)

    R. S. Narayan

    2017-06-01

    Full Text Available High Voltage Direct Current Transmission (HVDC is considered a better solution for bulk long distance transmissions. The increased use of HVDC is a result of its advantages over the HVAC systems and especially of its fault stability nature. A better solution is proposed by using a Voltage Source Controlled–HVDC as one of the infeed for the Multi-Infeed HVDC (MIDC or MI-HVDC systems. The main advantage with the VSC converter is its flexible power control which enhances the stability of the MIDC systems. In this paper, the behavior of an HVDC system is compared with that of an HVAC during faults. A Hybrid HVDC system that includes a LCC as a rectifier unit and a VSC converter as the inverter is being proposed. It is considered suitable for MIDC systems and particularly for supplying a weak AC system. The performance of the system during steady state and transient conditions for all the proposed topologies including HVDC, HVAC and Hybrid HVDC are studied in MATLAB/SIMULINK. All of the proposed control strategies are evaluated via a series of simulation case studies.

  6. Energy Savings From System Efficiency Improvements in Iowa's HVAC SAVE Program

    Energy Technology Data Exchange (ETDEWEB)

    Yee, S. [Partnership for Advanced Residential Retrofit, Chicago, IL (United States); Baker, J. [Partnership for Advanced Residential Retrofit, Chicago, IL (United States); Brand, L. [Partnership for Advanced Residential Retrofit, Chicago, IL (United States); Wells, J. [Partnership for Advanced Residential Retrofit, Chicago, IL (United States)

    2013-08-01

    The objective of this project is to explore the energy savings potential of maximizing furnace and distribution system performance by adjusting operating, installation, and distribution conditions. The goal of the Iowa HVAC System Adjusted and Verified Efficiency (SAVE) program is to train contractors to measure installed system efficiency as a diagnostic tool to ensure that the homeowner achieves the energy reduction target for the home rather than simply performing a tune-up on the furnace or having a replacement furnace added to a leaky system. The PARR research team first examined baseline energy usage from a sample of 48 existing homes, before any repairs or adjustments were made, to calculate an average energy savings potential and to determine which system deficiencies were prevalent. The results of the baseline study of these homes found that, on average, about 10% of the space heating energy available from the furnace was not reaching the conditioned space. In the second part of the project, the team examined a sample of 10 homes that had completed the initial evaluation for more in-depth study. For these homes, the diagnostic data shows that it is possible to deliver up to 23% more energy from the furnace to the conditioned space by doing system tune ups with or without upgrading the furnace. Replacing the furnace provides additional energy reduction. The results support the author's belief that residential heating and cooling equipment should be tested and improved as a system rather than a collection of individual components.

  7. 石油钻机司钻房 HVAC 系统设计与分析%System Design and Analysis of HVAC System Design and Analysis of Driller Roon in Oil Rig

    Institute of Scientific and Technical Information of China (English)

    樊春明; 孔美虹; 韩俊; 张文英; 王长怀; 李永国

    2014-01-01

    介绍了石油钻机司钻房HVAC系统组成、工作原理、关键参数确定和主要部件设计及选型。%It introduces the composition, working theory, determination of key parameters, de-sign and selection of the main components of HVAC system of driller roon in oil rig .

  8. Estimating occupant satisfaction of HVAC system noise using quality assessment index.

    Science.gov (United States)

    Forouharmajd, Farhad; Nassiri, Parvin; Monazzam, Mohammad R; Yazdchi, Mohammadreza

    2012-01-01

    Noise may be defined as any unwanted sound. Sound becomes noise when it is too loud, unexpected, uncontrolled, happens at the wrong time, contains unwanted pure tones or unpleasant. In addition to being annoying, loud noise can cause hearing loss, and, depending on other factors, can affect stress level, sleep patterns and heart rate. The primary object for determining subjective estimations of loudness is to present sounds to a sample of listeners under controlled conditions. In heating, ventilation and air conditioning (HVAC) systems only the ventilation fan industry (e.g., bathroom exhaust and sidewall propeller fans) uses loudness ratings. In order to find satisfaction, percent of exposure to noise is the valuable issue for the personnel who are working in these areas. The room criterion (RC) method has been defined by ANSI standard S12.2, which is based on measured levels of in HVAC systems noise in spaces and is used primarily as a diagnostic tool. The RC method consists of a family of criteria curves and a rating procedure. RC measures background noise in the building over the frequency range of 16-4000 Hz. This rating system requires determination of the mid-frequency average level and determining the perceived balance between high-frequency (HF) sound and low-frequency (LF) sound. The arithmetic average of the sound levels in the 500, 1000 and 2000 Hz octave bands is 44.6 dB; therefore, the RC 45 curve is selected as the reference for spectrum quality evaluation. The spectral deviation factors in the LF, medium-frequency sound and HF regions are 2.9, 7.5 and -2.3, respectively, giving a Quality Assessment Index (QAI) of 9.8. This concludes the QAI is useful in estimating an occupant's probable reaction when the system design does not produce optimum sound quality. Thus, a QAI between 5 and 10 dB represents a marginal situation in which acceptance by an occupant is questionable. However, when sound pressure levels in the 16 or 31.5 Hz octave bands exceed 65

  9. Estimating occupant satisfaction of HVAC system noise using quality assessment index

    Directory of Open Access Journals (Sweden)

    Farhad Forouharmajd

    2012-01-01

    Full Text Available Noise may be defined as any unwanted sound. Sound becomes noise when it is too loud, unexpected, uncontrolled, happens at the wrong time, contains unwanted pure tones or unpleasant. In addition to being annoying, loud noise can cause hearing loss, and, depending on other factors, can affect stress level, sleep patterns and heart rate. The primary object for determining subjective estimations of loudness is to present sounds to a sample of listeners under controlled conditions. In heating, ventilation and air conditioning (HVAC systems only the ventilation fan industry (e.g., bathroom exhaust and sidewall propeller fans uses loudness ratings. In order to find satisfaction, percent of exposure to noise is the valuable issue for the personnel who are working in these areas. The room criterion (RC method has been defined by ANSI standard S12.2, which is based on measured levels of in HVAC systems noise in spaces and is used primarily as a diagnostic tool. The RC method consists of a family of criteria curves and a rating procedure. RC measures background noise in the building over the frequency range of 16-4000 Hz. This rating system requires determination of the mid-frequency average level and determining the perceived balance between high-frequency (HF sound and low-frequency (LF sound. The arithmetic average of the sound levels in the 500, 1000 and 2000 Hz octave bands is 44.6 dB; therefore, the RC 45 curve is selected as the reference for spectrum quality evaluation. The spectral deviation factors in the LF, medium-frequency sound and HF regions are 2.9, 7.5 and -2.3, respectively, giving a Quality Assessment Index (QAI of 9.8. This concludes the QAI is useful in estimating an occupant′s probable reaction when the system design does not produce optimum sound quality. Thus, a QAI between 5 and 10 dB represents a marginal situation in which acceptance by an occupant is questionable. However, when sound pressure levels in the 16 or 31.5 Hz octave

  10. Initial Business Case Analysis of Two Integrated Heat Pump HVAC Systems for Near-Zero-Energy Homes

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Van D [ORNL

    2006-11-01

    The long range strategic goal of the Department of Energy's Building Technologies (DOE/BT) Program is to create, by 2020, technologies and design approaches that enable the construction of net-zero energy homes at low incremental cost (DOE/BT 2005). A net zero energy home (NZEH) is a residential building with greatly reduced needs for energy through efficiency gains, with the balance of energy needs supplied by renewable technologies. While initially focused on new construction, these technologies and design approaches are intended to have application to buildings constructed before 2020 as well resulting in substantial reduction in energy use for all building types and ages. DOE/BT's Emerging Technologies (ET) team is working to support this strategic goal by identifying and developing advanced heating, ventilating, air-conditioning, and water heating (HVAC/WH) technology options applicable to NZEHs. Although the energy efficiency of heating, ventilating, and air-conditioning (HVAC) equipment has increased substantially in recent years, new approaches are needed to continue this trend. Dramatic efficiency improvements are necessary to enable progress toward the NZEH goals, and will require a radical rethinking of opportunities to improve system performance. The large reductions in HVAC energy consumption necessary to support the NZEH goals require a systems-oriented analysis approach that characterizes each element of energy consumption, identifies alternatives, and determines the most cost-effective combination of options. In particular, HVAC equipment must be developed that addresses the range of special needs of NZEH applications in the areas of reduced HVAC and water heating energy use, humidity control, ventilation, uniform comfort, and ease of zoning. In FY05 ORNL conducted an initial Stage 1 (Applied Research) scoping assessment of HVAC/WH systems options for future NZEHs to help DOE/BT identify and prioritize alternative approaches for further

  11. An implementation of co-simulation for performance prediction of innovative integrated HVAC systems in buildings

    Energy Technology Data Exchange (ETDEWEB)

    Trcka, Marija; Wetter, Michael; Hensen, Jan L.M.

    2010-07-01

    Integrated performance simulation of buildings and heating, ventilation and air-conditioning (HVAC) systems can help reducing energy consumption and increasing level of occupant comfort. However, no singe building performance simulation (BPS) tool offers sufficient capabilities and flexibilities to accommodate the ever-increasing complexity and rapid innovations in building and system technologies. One way to alleviate this problem is to use co-simulation. The co-simulation approach represents a particular case of simulation scenario where at least two simulators solve coupled differential-algebraic systems of equations and exchange data that couples these equations during the time integration. This paper elaborates on issues important for co-simulation realization and discusses multiple possibilities to justify the particular approach implemented in a co-simulation prototype. The prototype is verified and validated against the results obtained from the traditional simulation approach. It is further used in a case study for the proof-of-concept, to demonstrate the applicability of the method and to highlight its benefits. Stability and accuracy of different coupling strategies are analyzed to give a guideline for the required coupling frequency. The paper concludes by defining requirements and recommendations for generic cosimulation implementations.

  12. HVAC-DYNAMIC: a training simulator for dynamic analysis of HVAC plants

    Directory of Open Access Journals (Sweden)

    Morten Heintz

    1989-07-01

    Full Text Available HVAC-DYNAMIC is a software tool for the dynamic simulation of Heating, Ventilation and Air Conditioning (HVAC plants. The program is designed to be used by HVAC engineers during design or troubleshooting of plants and by plant operators in their training. The program is based on a set of the most-used HVAC plant configurations and requires only a minimum of knowledge in numeric methods and programming. A brief presentation of the program structure and examples showing some of the application of the program are given.

  13. Capability of air filters to retain airborne bacteria and molds in heating, ventilating and air-conditioning (HVAC) systems.

    Science.gov (United States)

    Möritz, M; Peters, H; Nipko, B; Rüden, H

    2001-07-01

    The capability of air filters (filterclass: F6, F7) to retain airborne outdoor microorganisms was examined in field experiments in two heating, ventilating and air conditioning (HVAC) systems. At the beginning of the 15-month investigation period, the first filter stages of both HVAC systems were equipped with new unused air filters. The number of airborne bacteria and molds before and behind the filters were determined simultaneously in 14 days-intervals using 6-stage Andersen cascade impactors. Under relatively dry ( 12 degrees C) outdoor air conditions air filters led to a marked reduction of airborne microorganism concentrations (bacteria by approximately 70% and molds by > 80%). However, during long periods of high relative humidity (> 80% R. H.) a proliferation of bacteria on air filters with subsequent release into the filtered air occurred. These microorganisms were mainly smaller than 1.1 microns therefore being part of the respirable fraction. The results showed furthermore that one possibility to avoid microbial proliferation is to limit the relative humidity in the area of the air filters to 80% R. H. (mean of 3 days), e.g. by using preheaters in front of air filters in HVAC-systems.

  14. Laser photography system: hardware configuration

    Science.gov (United States)

    Piszczek, Marek; Rutyna, Krzysztof; Kowalski, Marcin; Zyczkowski, Marek

    2012-06-01

    Solution presented in this article is a system using image acquisition time gating method. The time-spatial framing method developed by authors was used to build Laser Photography System (LPS). An active vision system for open space monitoring and terrorist threats detection is being built as an effect of recent work lead in the Institute of Optoelectronics, MUT. The device is destined to prevent and recognize possible terrorist threats in important land and marine areas. The aim of this article is to discuss the properties and hardware configuration of the Laser Photography System.

  15. Wireless Infrastructure for Performing Monitoring, Diagnostics, and Control HVAC and Other Energy-Using Systems in Small Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Patrick O' Neill

    2009-06-30

    . This proved to be a major challenge for the project and was ultimately abandoned in favor of a directly wired solution for collecting sensor data at the building. The primary reason for this was the relatively short ranges at which we were able to effectively place the sensor nodes from the central receiving unit. Several different mesh technologies were attempted with similar results. Two hardware devices were created during the original performance period of the project. The first device, the WEB-MC, is a master control unit that has two radios, a CPU, memory, and serves as the central communications device for the WEB-MC System (Currently called the 'BEST Wireless HVAC Maintenance System' as a tentative commercial product name). The WEB-MC communicates with the local mesh network system via one of its antennas. Communication with the mesh network enables the WEB-MC to configure the network, send/receive data from individual motes, and serves as the primary mechanism for collecting sensor data at remote locations. The second antenna enables the WEB-MC to connect to a cellular network ('Long-Haul Communications') to transfer data to and from the NorthWrite Network Operations Center (NOC). A third 'all-in-one' hardware solution was created after the project was extended (Phase 2) and additional resources were provided. The project team leveraged a project funded by the State of Washington to develop a hardware solution that integrated the functionality of the original two devices. The primary reason for this approach was to eliminate the mesh network technical difficulties that severely limited the functionality of the original hardware approach. There were five separate software developments required to deliver the functionality needed for this project. These include the Data Server (or Network Operations Center), Web Application, Diagnostic Software, WEB-MC Embedded Software, Mote Embedded Software. Each of these developments was

  16. Thermal room modelling adapted to the test of HVAC control systems; Modele de zone adapte aux essais de regulateurs de systemes de chauffage et de climatisation

    Energy Technology Data Exchange (ETDEWEB)

    Riederer, P.

    2002-01-15

    Room models, currently used for controller tests, assume the room air to be perfectly mixed. A new room model is developed, assuming non-homogeneous room conditions and distinguishing between different sensor positions. From measurement in real test rooms and detailed CFD simulations, a list of convective phenomena is obtained that has to be considered in the development of a model for a room equipped with different HVAC systems. The zonal modelling approach that divides the room air into several sub-volumes is chosen, since it is able to represent the important convective phenomena imposed on the HVAC system. The convective room model is divided into two parts: a zonal model, representing the air at the occupant zone and a second model, providing the conditions at typical sensor positions. Using this approach, the comfort conditions at the occupant zone can be evaluated as well as the impact of different sensor positions. The model is validated for a test room equipped with different HVAC systems. Sensitivity analysis is carried out on the main parameters of the model. Performance assessment and energy consumption are then compared for different sensor positions in a room equipped with different HVAC systems. The results are also compared with those obtained when a well-mixed model is used. A main conclusion of these tests is, that the differences obtained, when changing the position of the controller's sensor, is a function of the HVAC system and controller type. The differences are generally small in terms of thermal comfort but significant in terms of overall energy consumption. For different HVAC systems the cases are listed, in which the use of a simplified model is not recommended. (author)

  17. Computational Fluid Dynamic Modeling of Horizontal Air-Ground Heat Exchangers (HAGHE for HVAC Systems

    Directory of Open Access Journals (Sweden)

    Paolo Maria Congedo

    2014-12-01

    Full Text Available In order to satisfy the requirements of Directive 2010/31/EU for Zero Energy Buildings (ZEB, innovative solutions were investigated for building HVAC systems. Horizontal air-ground heat exchangers (HAGHE offer a significant contribution in reducing energy consumption for ventilation, using the thermal energy stored underground, in order to pre-heat or pre-cool the ventilation air, in winter and summer, respectively. This is particularly interesting in applications for industrial, commercial and education buildings where keeping the indoor air quality under control is extremely important. Experimental measurements show that, throughout the year, the outside air temperature fluctuations are mitigated at sufficient ground depth (about 3 m because of the high thermal inertia of the soil, the ground temperature is relatively constant and instead higher than that of the outside air in winter and lower in summer. The study aims to numerically investigate the behavior of HAGHE by varying the air flow rate and soil conductivity in unsteady conditions by using annual weather data of South-East Italy. The analysis shows that, in warm climates, the HAGHE brings a real advantage for only a few hours daily in winter, while it shows significant benefits in the summer for the cooling of ventilation air up to several temperature degrees, already by a short pipe.

  18. Switched Control Strategies of Aggregated Commercial HVAC Systems for Demand Response in Smart Grids

    Directory of Open Access Journals (Sweden)

    Kai Ma

    2017-07-01

    Full Text Available This work proposes three switched control strategies for aggregated heating, ventilation, and air conditioning (HVAC systems in commercial buildings to track the automatic generation control (AGC signal in smart grid. The existing control strategies include the direct load control strategy and the setpoint regulation strategy. The direct load control strategy cannot track the AGC signal when the state of charge (SOC of the aggregated thermostatically controlled loads (TCLs exceeds their regulation capacity, while the setpoint regulation strategy provides flexible regulation capacity, but causes larger tracking errors. To improve the tracking performance, we took the advantages of the two control modes and developed three switched control strategies. The control strategies switch between the direct load control mode and the setpoint regulation mode according to different switching indices. Specifically, we design a discrete-time controller and optimize the controller parameter for the setpoint regulation strategy using the Fibonacci optimization algorithm, enabling us to propose two switched control strategies across multiple time steps. Furthermore, we extend the switched control strategies by introducing a two-stage regulation in a single time step. Simulation results demonstrate that the proposed switched control strategies can reduce the tracking errors for frequency regulation.

  19. Product Configuration Systems and Productivity

    DEFF Research Database (Denmark)

    Pedersen, Jørgen Lindgaard; Edwards, Kasper

    2004-01-01

    Twelve companies have been interviewed with the purpose to get information about technical, economic and organisational matters in respect of Product Configuration Systems (PCS).Combinations of qualitative interviews and quantitative scoring have been used in ranking expected and realized results...... from implementing PCS. The three highest aggregated scoring expected benefits are: 1)improved quality in specifications, 2)lower turnaround time, 3)less resource intensity....

  20. Tooling system configuration in FMSs

    Energy Technology Data Exchange (ETDEWEB)

    Grieco, A. [Universita degli Studi di Lecce (Italy); Semeraro, Q.; Tolio, T. [Facolta di Ingegneria, Milano (Italy)

    1996-12-31

    The increasing competition has led to product differentiation, life cycle shortening and rapid changes in the demand. One of the possible technological answer to these productive problems is represented by flexible automation and particularly by flexible manufacturing systems, that thanks to their flexibility give the possibility to answer to the variability in the product demand with reduced production costs and with limited flow times. With the advent of computerized manufacturing facilities, in particular FMS, it has become clear that tooling is a major constraint which could potentially prevent these systems from exploiting their full flexibility. Indeed the productivity of a flexible manufacturing system highly depends on the occurrence of conflicts regarding tool usage. This is the reason why tool management has become in the last decade an area of increased research activity. In this paper we present an analytical formulation for the tooling configuration problem in a flexible manufacturing system. The formulation determines the copies number for each tool type in the system minimizing the average lack of time in the machining centers for lack of the necessary tool, under the constraint of an assigned total number of tools. The results of the proposed method have been compared with two models of configuration of the tooling system proposed in literature by means of simulations experiments. The results of the simulations have underlined a meaningful increase of the performance of the system for the proposed model.

  1. Breathing Easier: HVAC Specifications for Schools.

    Science.gov (United States)

    Trent, C. Curtis; Trent, Warren C.

    1996-01-01

    A major source of indoor air contamination in schools originates within the heating, ventilating, and air-conditioning systems (HVAC), with draw-through systems being the worst offenders. Lists provisions for designing an HVAC system and a set of criteria to adhere to when planning new construction or renovations. (nine references) (MLF)

  2. Breathing Easier: HVAC Specifications for Schools.

    Science.gov (United States)

    Trent, C. Curtis; Trent, Warren C.

    1996-01-01

    A major source of indoor air contamination in schools originates within the heating, ventilating, and air-conditioning systems (HVAC), with draw-through systems being the worst offenders. Lists provisions for designing an HVAC system and a set of criteria to adhere to when planning new construction or renovations. (nine references) (MLF)

  3. Investigation of the potential antimicrobial efficacy of sealants used in HVAC systems.

    Science.gov (United States)

    Foarde, K K; VanOsdell, D W; Menetrez, M Y

    2001-08-01

    Recent experiments confirm field experience that duct cleaning alone may not provide adequate protection from regrowth of fungal contamination on fiberglass duct liner (FGDL). Current recommendations for remediation of fungally contaminated fiberglass duct materials specify complete removal of the materials. But removal of contaminated materials can be extremely expensive. Therefore, a common practice in the duct-cleaning industry is the postcleaning use of antimicrobial surface coatings with the implication that they may contain or limit regrowth. Little information is available on the efficacy of these treatments. This paper describes a study to evaluate whether three commercially available antimicrobial coatings, placed on a cleaned surface that 1 year previously had been actively growing microorganisms, would be able to prevent regrowth. The three coatings contained different active antimicrobial compounds. All three of the coatings were designed for use on heating, ventilation, and air conditioning (HVAC) system components or interior surfaces of lined and unlined duct systems. Coating I was a polyacrylate copolymer containing zinc oxide and borates. Coating II was an acrylic coating containing decabromodiphenyl oxide and antimony trioxide. Coating III was an acrylic primer containing a phosphated quaternary amine complex. The study included field and laboratory assessments. The three treatments were evaluated in an uncontrolled field setting in an actual duct system. The laboratory study broadened the field study to include a range of humidities under controlled conditions. Both static and dynamic chamber laboratory experiments were performed. The results showed that two of the three antimicrobial coatings limited the regrowth of fungal contamination, at least in the short term (the 3-month time span of the study); the third did not. Before use in the field, testing of the efficacy of antimicrobial coatings under realistic use conditions is recommended

  4. HVAC controls: Operation and maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Gupton, G.W. Jr.

    1987-01-01

    The introductory chapters review HVAC system processes and equipment, control system types and equipment, and equipment-to-control interactions. The succeeding chapters cover specific control systems functions, including electrical interlock and motor starting, electrical and electronic control system diagrams, pneumatic control system diagrams, air supply to pneumatic control systems, and control system maintenance.

  5. The role of ventilation and HVAC systems for human health in nonindustrial indoor environments. A supplementary review by EUROVEN group

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Sundell, Jan; Bischof, W.;

    2002-01-01

    with increased productivity, and that air-conditioning systems may increase the risk of sick building syndrome (SBS) symptoms. Taking these findings into account, the group has elaborated 35 hypotheses on the role of ventilation ahd HVAC systems in nonindustrial indoor environments with regard to human health......A continuation of the earlier work of the multidisciplinary group of European scientists, EUROVEN, is presented. The group has previously concluded that increased ventilation rates in indoor nonindustrial environments are strongly associated with improved comfort and health and may be associated...... of ventilation and air-conditioning systems, as well as their intermittent operation, may be potential reasons for health problems of people staying indoors....

  6. Evaluating the potential efficacy of three antifungal sealants of duct liner and galvanized steel as used in HVAC systems.

    Science.gov (United States)

    Foarde, Karin K; Menetrez, M Y

    2002-07-01

    Current recommendations for remediation of fiberglass duct materials contaminated with fungi specify complete removal, which can be extremely expensive, but in-place duct cleaning may not provide adequate protection from regrowth of fungal contamination. Therefore, a common practice in the duct-cleaning industry is the postcleaning use of antifungal surface coatings with the implication that they may contain or limit regrowth. However, even the proper use of these products has generally been discouraged because little research has been conducted on the effectiveness of most products as used in heating, ventilating, and air-conditioning (HVAC) systems. Three different coatings were evaluated on fiberglass duct liner (FGDL). Two of the three coatings were able to limit growth in the 3-month study; the third did not. One of the coatings that was able to limit growth was further evaluated in a comparison of FGDL or galvanized steel (GS) under conditions that mimicked their use in HVAC systems. The results showed that both moderately soiled and heavily soiled uncoated FGDL and GS duct material can support fungal growth, but that GS duct material was more readily cleaned. The use of an antifungal coating helped limit, but did not fully contain, regrowth on FGDL. No regrowth was detected on the coated GS.

  7. Fumigation of a laboratory-scale HVAC system with hydrogen peroxide for decontamination following a biological contamination incident.

    Science.gov (United States)

    Meyer, K M; Calfee, M W; Wood, J P; Mickelsen, L; Attwood, B; Clayton, M; Touati, A; Delafield, R

    2014-03-01

    To evaluate hydrogen peroxide vapour (H2 O2 ) for its ability to inactivate Bacillus spores within a laboratory-scale heating, ventilation and air-conditioning (HVAC) duct system. Experiments were conducted in a closed-loop duct system, constructed of either internally lined or unlined galvanized metal. Bacterial spores were aerosol-deposited onto 18-mm-diameter test material coupons and strategically placed at several locations within the duct environment. Various concentrations of H2 O2 and exposure times were evaluated to determine the sporicidal efficacy and minimum exposure needed for decontamination. For the unlined duct, high variability was observed in the recovery of spores between sample locations, likely due to complex, unpredictable flow patterns within the ducts. In comparison, the lined duct exhibited a significant desorption of the H2 O2 following the fumigant dwell period and thus resulted in complete decontamination at all sampling locations. These findings suggest that decontamination of Bacillus spore-contaminated unlined HVAC ducts by hydrogen peroxide fumigation may require more stringent conditions (higher concentrations, longer dwell duration) than internally insulated ductwork. These data may help emergency responders when developing remediation plans during building decontamination. © 2013 The Society for Applied Microbiology This article has been contributed to by US Government employees and their work is in the public domain in the USA.

  8. Wireless Infrastructure for Performing Monitoring, Diagnostics, and Control HVAC and Other Energy-Using Systems in Small Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Patrick O' Neill

    2009-06-30

    . This proved to be a major challenge for the project and was ultimately abandoned in favor of a directly wired solution for collecting sensor data at the building. The primary reason for this was the relatively short ranges at which we were able to effectively place the sensor nodes from the central receiving unit. Several different mesh technologies were attempted with similar results. Two hardware devices were created during the original performance period of the project. The first device, the WEB-MC, is a master control unit that has two radios, a CPU, memory, and serves as the central communications device for the WEB-MC System (Currently called the 'BEST Wireless HVAC Maintenance System' as a tentative commercial product name). The WEB-MC communicates with the local mesh network system via one of its antennas. Communication with the mesh network enables the WEB-MC to configure the network, send/receive data from individual motes, and serves as the primary mechanism for collecting sensor data at remote locations. The second antenna enables the WEB-MC to connect to a cellular network ('Long-Haul Communications') to transfer data to and from the NorthWrite Network Operations Center (NOC). A third 'all-in-one' hardware solution was created after the project was extended (Phase 2) and additional resources were provided. The project team leveraged a project funded by the State of Washington to develop a hardware solution that integrated the functionality of the original two devices. The primary reason for this approach was to eliminate the mesh network technical difficulties that severely limited the functionality of the original hardware approach. There were five separate software developments required to deliver the functionality needed for this project. These include the Data Server (or Network Operations Center), Web Application, Diagnostic Software, WEB-MC Embedded Software, Mote Embedded Software. Each of these developments was

  9. Comparison of Energy Performance of Different HVAC Systems for a Typical Office Room and a Typical Classroom

    DEFF Research Database (Denmark)

    Yu, Tao; Heiselberg, Per; Pomianowski, Michal Zbigniew

    This report is part of the work performed under the project “Natural cooling and Ventilation through Diffuse Ceiling Supply and Thermally Activated Building Constructions”. In this project, a new system solution combining natural ventilation with diffuse ceiling inlet and thermally activated...... the energy consumption for buildings with cooling demand in cold seasons. In this way, the building system can operate at a very low energy use all the year round. The main purpose of this task is to investigate the energy performance of different HVAC systems used in the office room and the classroom......, and find the potential of energy saving for the proposed new system solution. In this report, a typical room is selected according to the previous study, but the occupation is different for the purpose of the office and the classroom. Energy performance of these two types of room under different internal...

  10. Experimental study on HVAC sound parameters

    Science.gov (United States)

    Bujoreanu, C.; Benchea, M.

    2016-08-01

    HVAC system represent major source of buildings internal noise and therefore they are designed to provide a human acoustic comfort besides the thermal and air quality requirements. The paper experimentally investigates three types of commercial air handler units (AHU) with different ducts cross-section sizes and inlet-outlet configuration. The measurements are performed in an anechoic room. The measurements are carried out at different fan's speeds, ranging the power-charge from 30-100% while the duct air flow is slowly adjusted from full open to full closed, between 0-500 Pa. The sound pressure levels of the radiant units are rated using NR curves. Also, the supply and the outdoor ducts sound levels are compared in order to point the frequencies where the noise must be reduced. Third-octave band analysis of random noise of an air handling unit from a HVAC system is realized, using measurement procedures that agrees the requirements of the ISO 3744:2011 and ISO 5136:2010 standards. The comparatively results highlight the effects of the geometry, air flow pressure and power-charging dependencies upon the sound level. This is the start for a noise reduction strategy.

  11. Microsoft System Center Configuration Manager

    CERN Document Server

    Sandbu, Marius

    2013-01-01

    This book is a step-by-step tutorial that guides you through the key steps in implementing best solutions for high availability and performance tuning. It is split into two distinct approaches: client and site side HA and optimization.Microsoft SCCM High Availability and Performance Tuning is for IT professionals and consultants working with Configuration Manager who wish to learn the skills to deploy a redundant and scalable solution.

  12. Observed benefits from product configuration systems

    DEFF Research Database (Denmark)

    Hvam, Lars; Haug, Anders; Mortensen, Niels Henrik

    2013-01-01

    This article presents a study of the benefits obtained from applying product configuration systems based on a case study in four industry companies. The impacts are described according to main objectives in literature for imple-menting product configuration systems: lead time in the specification...

  13. Evaluation of commercially available techniques and development of simplified methods for measuring grille airflows in HVAC systems

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain S.; Wray, Craig P.; Guillot, Cyril; Masson, S.

    2003-08-01

    In this report, we discuss the accuracy of flow hoods for residential applications, based on laboratory tests and field studies. The results indicate that commercially available hoods are often inadequate to measure flows in residential systems, and that there can be a wide range of performance between different flow hoods. The errors are due to poor calibrations, sensitivity of existing hoods to grille flow non-uniformities, and flow changes from added flow resistance. We also evaluated several simple techniques for measuring register airflows that could be adopted by the HVAC industry and homeowners as simple diagnostics that are often as accurate as commercially available devices. Our test results also show that current calibration procedures for flow hoods do not account for field application problems. As a result, organizations such as ASHRAE or ASTM need to develop a new standard for flow hood calibration, along with a new measurement standard to address field use of flow hoods.

  14. Characterization and control of the microbial community affiliated with copper or aluminum heat exchangers of HVAC systems.

    Science.gov (United States)

    Schmidt, Michael G; Attaway, Hubert H; Terzieva, Silva; Marshall, Anna; Steed, Lisa L; Salzberg, Deborah; Hamoodi, Hameed A; Khan, Jamil A; Feigley, Charles E; Michels, Harold T

    2012-08-01

    Microbial growth in heating ventilation and air-conditioning (HVAC) systems with the subsequent contamination of indoor air is of increasing concern. Microbes and the subsequent biofilms grow easily within heat exchangers. A comparative study where heat exchangers fabricated from antimicrobial copper were evaluated for their ability to limit microbial growth was conducted using a full-scale HVAC system under conditions of normal flow rates using single-pass outside air. Resident bacterial and fungal populations were quantitatively assessed by removing triplicate sets of coupons from each exchanger commencing the fourth week after their installation for the next 30 weeks. The intrinsic biofilm associated with each coupon was extracted and characterized using selective and differential media. The predominant organisms isolated from aluminum exchangers were species of Methylobacterium of which at least three colony morphologies and 11 distinct PFGE patterns we found; of the few bacteria isolated from the copper exchangers, the majority were species of Bacillus. The concentrations and type of bacteria recovered from the control, aluminum, exchangers were found to be dependent on the type of plating media used and were 11,411-47,257 CFU cm(-2) per coupon surface. The concentration of fungi was found to average 378 CFU cm(-2). Significantly lower concentrations of bacteria, 3 CFU cm(-2), and fungi, 1 CFU cm(-2), were recovered from copper exchangers regardless of the plating media used. Commonly used aluminum heat exchangers developed stable, mixed, bacterial/fungal biofilms in excess of 47,000 organisms per cm(2) within 4 weeks of operation, whereas the antimicrobial properties of metallic copper were able to limit the microbial load affiliated with the copper heat exchangers to levels 99.97 % lower during the same time period.

  15. HVAC Trials.

    Science.gov (United States)

    Greim, Clifton W.; D'Angelo, David

    1999-01-01

    Explains how commissioning can help to ensure that all components in a new heating, ventilation, and air conditioning system will work together as designed. Bowdoin College's experience with commissioning is highlighted. (GR)

  16. HVAC Trials.

    Science.gov (United States)

    Greim, Clifton W.; D'Angelo, David

    1999-01-01

    Explains how commissioning can help to ensure that all components in a new heating, ventilation, and air conditioning system will work together as designed. Bowdoin College's experience with commissioning is highlighted. (GR)

  17. Observed benefits from product configuration systems

    DEFF Research Database (Denmark)

    Hvam, Lars; Haug, Anders; Mortensen, Niels Henrik

    2013-01-01

    This article presents a study of the benefits obtained from applying product configuration systems based on a case study in four industry companies. The impacts are described according to main objectives in literature for imple-menting product configuration systems: lead time in the specification...... systems in industry companies and partly to assess if the objectives suggested are appropriate for describing the impact of product configuration systems and identifying other possible objectives. The empirical study of the com-panies also gives an indication of more overall performance indicators being...

  18. Increasing energy efficiency of HVAC systems of buildings using phase change material

    Directory of Open Access Journals (Sweden)

    Lee Chusak, Jared Daiber, Ramesh Agarwal

    2012-01-01

    Full Text Available Using Computational Fluid Dynamics (CFD, four different cooling systems used in contemporary office environments are modeled to compare energy consumption and thermal comfort levels. Incorporating convection and radiation technologies, full-scale models of an office room compare energy efficiency of (a an all-air overhead system, (b a combined all-air overhead and hydronic radiant system (chilled ceiling, (c an all-air raised floor system (displacement ventilation, and (d a combined displacement ventilation with a chilled ceiling. The computational domain for each model consists of one temperature varying wall (simulating the temperature of the exterior wall of the building during a 24-hour period and adiabatic conditions for the remaining walls, floor, and ceiling (simulating interior walls of the room. Two sets of computations are conducted. The first set considers a glass window and plastic shade configuration for the exterior wall. The second set of computations includes a phase change material layer between the glass window and the plastic shade. Results show substantial energy savings can be accrued using the displacement ventilation and especially the displacement ventilation with a chilled ceiling over the conventional overhead mixing ventilation system. The results also show that the addition of a PCM layer to the exterior wall can significantly decrease the cooling energy requirements.

  19. Increasing energy efficiency of HVAC systems of buildings using phase change material

    Energy Technology Data Exchange (ETDEWEB)

    Chusak, Lee; Daiber, Jared; Agarwal, Ramesh [Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, St. Louis, MO 63130 (United States)

    2012-07-01

    Using Computational Fluid Dynamics (CFD), four different cooling systems used in contemporary office environments are modeled to compare energy consumption and thermal comfort levels. Incorporating convection and radiation technologies, full-scale models of an office room compare energy efficiency of (a) an all-air overhead system, (b) a combined all-air overhead and hydronic radiant system (chilled ceiling), (c) an all-air raised floor system (displacement ventilation), and (d) a combined displacement ventilation with a chilled ceiling. The computational domain for each model consists of one temperature varying wall (simulating the temperature of the exterior wall of the building during a 24-hour period) and adiabatic conditions for the remaining walls, floor, and ceiling (simulating interior walls of the room). Two sets of computations are conducted. The first set considers a glass window and plastic shade configuration for the exterior wall. The second set of computations includes a phase change material layer between the glass window and the plastic shade. Results show substantial energy savings can be accrued using the displacement ventilation and especially the displacement ventilation with a chilled ceiling over the conventional overhead mixing ventilation system. The results also show that the addition of a PCM layer to the exterior wall can significantly decrease the cooling energy requirements.

  20. Draft PRN 2006-A: Use of Antimicrobial Pesticide Products in Heating, Ventilation, Air Conditioning and Refrigeration Systems (HVAC&R)

    Science.gov (United States)

    This draft notice provides guidance to registrants of EPA-registered antimicrobial products whose labels bear general directions related to hard, non-porous or porous surfaces, but which are not but which are not specifically registered for HVAC uses.

  1. Control Configuration Selection for Multivariable Descriptor Systems

    DEFF Research Database (Denmark)

    Shaker, Hamid Reza; Stoustrup, Jakob

    2012-01-01

    is needed to be controlled, is either in the descriptor form or can be represented in the descriptor form. Singular systems and the differential algebraic equation (DAE) systems are among these systems. Descriptor systems appear in the variety of fields to describe the practical processes ranging from power...... systems, hydraulic systems to heat transfer, and chemical processes. The focus of this paper is on the problem of control configuration selection for multivariable descriptor systems. A gramian-based interaction measure for control configuration selection of such processes is described in this paper...

  2. Assessment of organic compound exposures, thermal comfort parameters, and HVAC system-driven air exchange rates in public school portable classrooms in California

    Energy Technology Data Exchange (ETDEWEB)

    Shendell, Derek Garth [Univ. of California, Los Angeles, CA (United States)

    2003-01-01

    The prevalence of prefabricated, portable classrooms (portables, relocatables, RCs) has increased due to class size reduction initiatives and limited resources. Classroom mechanical wall-mount heating, ventilation, and air conditioning (HVAC) systems may function improperly or not be maintained; lower ventilation rates may impact indoor air and environmental quality (IEQ). Materials in portables may off-gas volatile organic compounds (VOCs), including formaldehyde, as a function of age, temperature, and humidity. For a pilot study, public K-12 schools located in or serving target areas within five Los Angeles County communities were identified. In two communities where school districts (SD) consented, 1-3 randomly selected portables, one newer and one older, and one main building control classroom from each participating school were included. Sampling was conducted over a five-day school week in the cooling and heating seasons, or repeated twice in the cooling season. Measurements included passive samplers for VOCs, formaldehyde and acetaldehyde, and air exchange rate (AER) calculation; indoor air temperature and humidity; technician walk-through surveys; an interview questionnaire above HVAC system operation and maintenance (O and M). For an intervention study evaluating advanced HVAC technologies in comparison to the common conventional technology, and materials for source reduction of VOCs, four RC were manufactured and located in pairs at two schools in two recruited Northern California SD in different climate zones. RCs were built with the two HVAC systems, cabinetry and conduit for monitoring equipment, and standard or advanced interior finish materials. Each RC was its own control in a case-crossover design--HVAC systems alternately operated for 1-2 week intervals in the 2001-02 school year, with IEQ monitoring including aldehyde and indoor air temperature and humidity data. Measured classroom AER were low, formaldehyde concentrations were below the state

  3. Parametric analysis of air–water heat recovery concept applied to HVAC systems: Effect of mass flow rates

    OpenAIRE

    Mohamad Ramadan; Mostafa Gad El Rab; Mahmoud Khaled

    2015-01-01

    In the last three decades, the world has experienced enormous increases in energy and fuel consumption as a consequence of the economic and population growth. This causes renewable energy and energy recovery to become a requirement in building designs rather than option. The present work concerns a coupling between energy recovery and Heating, Ventilating and Air Conditioning HVAC domains and aims to apply heat recovery concepts to HVAC applications working on refrigeration cycles. It particu...

  4. Fault Diagnosis in HVAC Chillers

    Science.gov (United States)

    Choi, Kihoon; Namuru, Setu M.; Azam, Mohammad S.; Luo, Jianhui; Pattipati, Krishna R.; Patterson-Hine, Ann

    2005-01-01

    Modern buildings are being equipped with increasingly sophisticated power and control systems with substantial capabilities for monitoring and controlling the amenities. Operational problems associated with heating, ventilation, and air-conditioning (HVAC) systems plague many commercial buildings, often the result of degraded equipment, failed sensors, improper installation, poor maintenance, and improperly implemented controls. Most existing HVAC fault-diagnostic schemes are based on analytical models and knowledge bases. These schemes are adequate for generic systems. However, real-world systems significantly differ from the generic ones and necessitate modifications of the models and/or customization of the standard knowledge bases, which can be labor intensive. Data-driven techniques for fault detection and isolation (FDI) have a close relationship with pattern recognition, wherein one seeks to categorize the input-output data into normal or faulty classes. Owing to the simplicity and adaptability, customization of a data-driven FDI approach does not require in-depth knowledge of the HVAC system. It enables the building system operators to improve energy efficiency and maintain the desired comfort level at a reduced cost. In this article, we consider a data-driven approach for FDI of chillers in HVAC systems. To diagnose the faults of interest in the chiller, we employ multiway dynamic principal component analysis (MPCA), multiway partial least squares (MPLS), and support vector machines (SVMs). The simulation of a chiller under various fault conditions is conducted using a standard chiller simulator from the American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE). We validated our FDI scheme using experimental data obtained from different types of chiller faults.

  5. Fault Diagnosis in HVAC Chillers

    Science.gov (United States)

    Choi, Kihoon; Namuru, Setu M.; Azam, Mohammad S.; Luo, Jianhui; Pattipati, Krishna R.; Patterson-Hine, Ann

    2005-01-01

    Modern buildings are being equipped with increasingly sophisticated power and control systems with substantial capabilities for monitoring and controlling the amenities. Operational problems associated with heating, ventilation, and air-conditioning (HVAC) systems plague many commercial buildings, often the result of degraded equipment, failed sensors, improper installation, poor maintenance, and improperly implemented controls. Most existing HVAC fault-diagnostic schemes are based on analytical models and knowledge bases. These schemes are adequate for generic systems. However, real-world systems significantly differ from the generic ones and necessitate modifications of the models and/or customization of the standard knowledge bases, which can be labor intensive. Data-driven techniques for fault detection and isolation (FDI) have a close relationship with pattern recognition, wherein one seeks to categorize the input-output data into normal or faulty classes. Owing to the simplicity and adaptability, customization of a data-driven FDI approach does not require in-depth knowledge of the HVAC system. It enables the building system operators to improve energy efficiency and maintain the desired comfort level at a reduced cost. In this article, we consider a data-driven approach for FDI of chillers in HVAC systems. To diagnose the faults of interest in the chiller, we employ multiway dynamic principal component analysis (MPCA), multiway partial least squares (MPLS), and support vector machines (SVMs). The simulation of a chiller under various fault conditions is conducted using a standard chiller simulator from the American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE). We validated our FDI scheme using experimental data obtained from different types of chiller faults.

  6. TWRS systems engineering software configuration management plan

    Energy Technology Data Exchange (ETDEWEB)

    Porter, P.E.

    1996-10-09

    This plan delineates the requirements for control of software developed and supported by the Tank Waste Remediation System (TWRS) Technical Integration organization. The information contained in this plan shall assist employees involved with software modification and configuration control.

  7. Optimal sensor configuration for complex systems

    DEFF Research Database (Denmark)

    Sadegh, Payman; Spall, J. C.

    1998-01-01

    Considers the problem of sensor configuration for complex systems. Our approach involves definition of an appropriate optimality criterion or performance measure, and description of an efficient and practical algorithm for achieving the optimality objective. The criterion for optimal sensor...

  8. Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating, Ventilation and Air-Conditioning (HVAC) system for the computer room of the CERN Control Centre

    CERN Document Server

    2012-01-01

    Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating, Ventilation and Air-Conditioning (HVAC) system for the computer room of the CERN Control Centre

  9. Implementation of PFC (Predictive Functional Control) in a PLC (Programmable Logic Controller) for a HVAC (Heating, Ventilation and Air Conditioning) system

    Science.gov (United States)

    Kreutz, M.; Richalet, J.; Mocha, K.; Haber, R.

    2014-12-01

    HVAC systems of industrial buildings consume a lot of energy. Therefore it is important to know the performance of these systems and strategies to optimize the hardware and the control. Tackling the temperature control of the HVAC system promises quick savings by tuning the control within specified tolerance limits, which mostly can be done by low investment. This paper mainly deals with the implementation strategy of a new controller in a PLC using the predictive functional control for temperature control. The different stages of the implementation from the simulation over the SCL code till to the real-time operation are presented. A bumpless switch between the PI(D) and the PFC control was realized, as well.

  10. HVAC; Heating, Ventilation, Air Conditioning - Aerosol Duct Sealant

    Science.gov (United States)

    2016-09-01

    Approved for public release: distribution unlimited TDS-NAVFAC-EXWC-PW-1603 Sep 2016 HVAC ; Heating, Ventilation, Air Conditioning - Aerosol...energy consumption, depending on the HVAC system type and the location of the ducts that were sealed. The cost effectiveness of the technology is...Although several studies have been done on the effectiveness of sealing leaky HVAC ductwork with aerosol duct sealant, few studies have been done on

  11. LSSVM predictive control for HVAC system with PSO algorithm%基于PSO算法的HVAC系统LSSVM预测控制

    Institute of Scientific and Technical Information of China (English)

    邹木春; 龙文

    2012-01-01

    For the system of heating, ventilating and air-conditioning (HVAC), a nonlinear predictive control algorithm based on particle swarm optimization (PSO) and least square support vector machine (LSSVM) was proposed. It utilizes LSSVM to estimate the HVAC system model and forecast the output value, reducing the error in output feedback and error correction. A new weighted predictive control performance index is formulated. The optimal control values of the nonlinear system are obtained by the rolling optimization of PSO algorithm. An optimal control system is designed to control a HVAC system; simulation results show that the proposed nonlinear predictive control algorithm is effective.%针对暖通空调(HVAC)系统,提出一种基于粒子群优化(PSO)算法和最小二乘支持向量机(LSSVM)的预测控制方法.该方法利用LSSVM建立HVAC系统预测模型并预测系统的输出值,引入输出反馈和偏差校正以克服模型失配等因素引起的预测误差,以此构造加权预测控制性能指标.由PSO算法滚动优化得到系统的最优控制量.利用该控制方法对一个HVAC系统进行仿真实验,结果表明该方法具有较好的控制效果.

  12. TNO HVAC facilities

    NARCIS (Netherlands)

    Hammink, H.A.J.

    2015-01-01

    TNO has extensive knowledge of heating, ventilation and air conditioning (HVAC), and can offer its services through theoretical studies, laboratory experiments and field measurements. This complete scope, made possible through our test facilities, enables the effective development of new products,

  13. System configuration on Web with mashup.

    OpenAIRE

    清水, 宏泰; Shimizu, Hiroyasu

    2014-01-01

    Mashup become trend for create Web service due to popularizing cloud service. Mashup is method for create Web service from several Web services and API. Mashup has a few problems. One of the problem is deference of data format and label. Semantic Web can solve it. This paper propose method of building a system on Web with mashup using semantic Web. Mashup system configuration can express as URL. So, editing URL for mashup is editing system configuration. And any device can use this system on ...

  14. Configurable Web Warehouses construction through BPM Systems

    Directory of Open Access Journals (Sweden)

    Andrea Delgado

    2016-08-01

    Full Text Available The process of building Data Warehouses (DW is well known with well defined stages but at the same time, mostly carried out manually by IT people in conjunction with business people. Web Warehouses (WW are DW whose data sources are taken from the web. We define a flexible WW, which can be configured accordingly to different domains, through the selection of the web sources and the definition of data processing characteristics. A Business Process Management (BPM System allows modeling and executing Business Processes (BPs providing support for the automation of processes. To support the process of building flexible WW we propose a two BPs level: a configuration process to support the selection of web sources and the definition of schemas and mappings, and a feeding process which takes the defined configuration and loads the data into the WW. In this paper we present a proof of concept of both processes, with focus on the configuration process and the defined data.

  15. Mastering System Center 2012 Configuration Manager

    CERN Document Server

    Rachui, Steve; Martinez, Santos; Daalmans, Peter

    2012-01-01

    Expert coverage of Microsoft's highly anticipated network software deployment tool The latest version of System Center Configuration Manager (SCCM) is a dramatic update of its predecessor Configuration Manager 2007, and this book offers intermediate-to-advanced coverage of how the new SCCM boasts a simplified hierarchy, role-based security, a new console, flexible application deployment, and mobile management. You'll explore planning and installation, migrating from SCCM 2007, deploying software and operating systems, security, monitoring and troubleshooting, and automating and customizing SCC

  16. Control Configuration Selection for Multivariable Nonlinear Systems

    DEFF Research Database (Denmark)

    Shaker, Hamid Reza; Komareji, Mohammad

    2012-01-01

    Control configuration selection is the procedure of choosing the appropriate input and output pairs for the design of SISO (or block) controllers. This step is an important prerequisite for a successful industrial control strategy. In industrial practices, it is often the case that systems, which...

  17. Electrochemical systems configured to harvest heat energy

    Science.gov (United States)

    Lee, Seok Woo; Yang, Yuan; Ghasemi, Hadi; Chen, Gang; Cui, Yi

    2017-01-31

    Electrochemical systems for harvesting heat energy, and associated electrochemical cells and methods, are generally described. The electrochemical cells can be configured, in certain cases, such that at least a portion of the regeneration of the first electrochemically active material is driven by a change in temperature of the electrochemical cell. The electrochemical cells can be configured to include a first electrochemically active material and a second electrochemically active material, and, in some cases, the absolute value of the difference between the first thermogalvanic coefficient of the first electrochemically active material and the second thermogalvanic coefficient of the second electrochemically active material is at least about 0.5 millivolts/Kelvin.

  18. Designing the controllability of a HVAC-plant by dynamic simulation

    Energy Technology Data Exchange (ETDEWEB)

    Novakovic, V.; Grindal, A.

    1994-05-01

    This paper was presented at CLIMA 2000 - The international conference on energy and environmental matters in built environment, London, 1.-3. November 1993. Nowadays, HVAC engineers can use dynamic simulation programs in their everyday work. Such tools provide the ability to analyze different system configurations and to check the obtained states even before the building and plant are constructed. To encourage its wider use, the authors present in this paper the experiences obtained with the simulation program HVAC-DYNAMICS. The program was used to simulate the retrofitting of a heat recovery wheel to a conventional ventilation plant with a hot water heating coil. The effects of different design parameters on the controllability of the plant were investigated. Interestingly, some commonly recommended ``clever`` configurations can lead to unexpected control scenarios. 4 refs., 3 figs., 2 tabs.

  19. Legionellosis prevention in building water and HVAC systems a practical guide for design, operation and maintenance to minimize the risk

    CERN Document Server

    Joppolo, Cesare Maria; Pitera, Luca Alberto; Angermann, Jean Pierre; Izard, Mark

    2013-01-01

    This Guidebook is a practical guide for design, operation and maintenance to minimize the risk of legionellosis in building water and HVAC systmes. It is devided into several themes such as: Air conditioning of the air (by water – humidification), Production of hot water for washing (fundamentally but not only hot water for washing) and Evaporative cooling tower.

  20. Active Sensor Configuration Validation for Refrigeration Systems

    DEFF Research Database (Denmark)

    Hovgaard, Tobias Gybel; Blanke, Mogens; Niemann, Hans Henrik

    2010-01-01

    Major faults in the commissioning phase of refrigeration systems are caused by defects related to sensors. With a number of similar sensors available that do not differ by type but only by spatial location in the plant, interchange of sensors is a common defect. With sensors being used quite...... identify the sensor configuration. The method as such is generic and is shown in the paper to work convincingly on refrigeration systems with significant nonlinear behaviors...

  1. Developing a Frame of Reference for understanding configuration systems

    DEFF Research Database (Denmark)

    2008-01-01

    This paper uses the theory of technical systems to develop a frame of reference of product configuration systems. Following a definition of the configuration task, product model and product configuration system the theory of technical systems are presented. Configuration systems are then related...

  2. Developing a Frame of Reference for understanding configuration systems

    DEFF Research Database (Denmark)

    2008-01-01

    This paper uses the theory of technical systems to develop a frame of reference of product configuration systems. Following a definition of the configuration task, product model and product configuration system the theory of technical systems are presented. Configuration systems are then related ...

  3. Integrating configuration workflows with project management system

    Science.gov (United States)

    Nilsen, Dimitri; Weber, Pavel

    2014-06-01

    The complexity of the heterogeneous computing resources, services and recurring infrastructure changes at the GridKa WLCG Tier-1 computing center require a structured approach to configuration management and optimization of interplay between functional components of the whole system. A set of tools deployed at GridKa, including Puppet, Redmine, Foreman, SVN and Icinga, provides the administrative environment giving the possibility to define and develop configuration workflows, reduce the administrative effort and improve sustainable operation of the whole computing center. In this presentation we discuss the developed configuration scenarios implemented at GridKa, which we use for host installation, service deployment, change management procedures, service retirement etc. The integration of Puppet with a project management tool like Redmine provides us with the opportunity to track problem issues, organize tasks and automate these workflows. The interaction between Puppet and Redmine results in automatic updates of the issues related to the executed workflow performed by different system components. The extensive configuration workflows require collaboration and interaction between different departments like network, security, production etc. at GridKa. Redmine plugins developed at GridKa and integrated in its administrative environment provide an effective way of collaboration within the GridKa team. We present the structural overview of the software components, their connections, communication protocols and show a few working examples of the workflows and their automation.

  4. TNO HVAC facilities

    NARCIS (Netherlands)

    Hammink, H.A.J.

    2015-01-01

    TNO has extensive knowledge of heating, ventilation and air conditioning (HVAC), and can offer its services through theoretical studies, laboratory experiments and field measurements. This complete scope, made possible through our test facilities, enables the effective development of new products, i

  5. Configuring systems from components: the EMS approach

    Energy Technology Data Exchange (ETDEWEB)

    Nogiec, J.M. [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States)]. E-mail: nogiec@fnal.gov; Desavouret, E. [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States); Kotelnikov, S. [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States); Trombly-Freytag, K. [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States); Walbridge, D. [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States)

    2004-11-21

    EMS is an exercise in component technology. It offers rapid development of specialized data acquisition, visualization and analysis systems via assembly from vertical and horizontal components. The EMS architecture allows for agile development of systems and promotes reuse of software. The framework supports a visual builder that shows connections between components and lists component properties. The system offers both off-line setup of properties and run-time modifications. Multi-bus architecture allows for independent routing of data, controls, debugs, and exceptions. The architecture, configuration process, and control of applications through scripting are presented.

  6. The Database Driven ATLAS Trigger Configuration System

    CERN Document Server

    Martyniuk, Alex; The ATLAS collaboration

    2015-01-01

    This contribution describes the trigger selection configuration system of the ATLAS low- and high-level trigger (HLT) and the upgrades it received in preparation for LHC Run 2. The ATLAS trigger configuration system is responsible for applying the physics selection parameters for the online data taking at both trigger levels and the proper connection of the trigger lines across those levels. Here the low-level trigger consists of the already existing central trigger (CT) and the new Level-1 Topological trigger (L1Topo), which has been added for Run 2. In detail the tasks of the configuration system during the online data taking are Application of the selection criteria, e.g. energy cuts, minimum multiplicities, trigger object correlation, at the three trigger components L1Topo, CT, and HLT On-the-fly, e.g. rate-dependent, generation and application of prescale factors to the CT and HLT to adjust the trigger rates to the data taking conditions, such as falling luminosity or rate spikes in the detector readout ...

  7. Design Optimization of Heat Wheels for Energy Recovery in HVAC Systems

    Directory of Open Access Journals (Sweden)

    Stefano De Antonellis

    2014-11-01

    Full Text Available Air to air heat exchangers play a crucial role in mechanical ventilation equipment, due to the potential primary energy savings both in case of refurbishment of existing buildings or in case of new ones. In particular, interest in heat wheels is increasing due to their low pressure drop and high effectiveness. In this paper a detailed optimization of design parameters of heat wheels is performed in order to maximize sensible effectiveness and to minimize pressure drop. The analysis is carried out through a one dimensional lumped parameters heat wheel model, which solves heat and mass transfer equations, and through appropriate correlations to estimate pressure drop. Simulation results have been compared with experimental data of a heat wheel tested in specific facilities, and good agreement is attained. The device optimization is performed through the variation of main design parameters, such as heat wheel length, channel base, height and thickness and for different operating conditions, namely the air face velocity and the revolution speed. It is shown that the best configurations are achieved with small channel thickness and, depending on the required sensible effectiveness, with appropriate values of wheel length and channel base and height.

  8. Computer Review Can Cut HVAC Energy Use

    Science.gov (United States)

    McClure, Charles J. R.

    1974-01-01

    A computerized review of construction bidding documents, usually done by a consulting engineer, can reveal how much money it will cost to operate various alternative types of HVAC equipment over a school's lifetime. The review should include a computerized load calculation, energy systems flow diagram, control system analysis, and a computerized…

  9. Computer Review Can Cut HVAC Energy Use

    Science.gov (United States)

    McClure, Charles J. R.

    1974-01-01

    A computerized review of construction bidding documents, usually done by a consulting engineer, can reveal how much money it will cost to operate various alternative types of HVAC equipment over a school's lifetime. The review should include a computerized load calculation, energy systems flow diagram, control system analysis, and a computerized…

  10. Geothermal HVAC Systems - A Business Case Analysis for Net Zero Plus

    Science.gov (United States)

    2009-03-01

    During the summer (or warm months), the system cools the building by pulling heat from the building , carrying it through the system and placing it in the...system and into the building or structure, Figure 4. Figure 3. The flow of energy during the Summer or warmer months (From Weigand, 2008...lives by reducing the need for traditional fuel transport. ( NetZero Plus – Joint Capability Technology Demonstration, March 2008) 13 C. THE

  11. A Novel Application of Thermoelectric Modules in an HVAC System Under Cold Climate Operation

    Science.gov (United States)

    Okuma, Toru; Radermacher, Reinhard; Hwang, Yunho

    2012-06-01

    A vapor compression cycle (VCC) with integrated thermoelectric (TE) modules to boost the heating capacity of the system in an energy-efficient way, especially for cold climate operation, is suggested in this paper. While a baseline heat pump (HP) cycle absorbs heat from a source through an evaporator, the proposed system utilizes TE modules as an intermediate (or third) stage of an otherwise two-stage vapor compression system with a vapor injection compressor. This increases the overall system efficiency and augments the system capacity through the high coefficient of performance (COP) of the TE for small temperature lift conditions. To demonstrate the concept, a prototype refrigerant-to-solid (TE) heat exchanger, consisting of TE modules and microchannel flat tubes, was designed and fabricated so that the whole system could realize an additional 1 kW of heating capacity compared with the baseline system. The TE heat exchanger was integrated into a residential HP unit that uses R-410A as a refrigerant, and the system was tested in a laboratory under the severe condition of -17.8°C, in order to investigate the capacity improvement and the overall COP. Finally, an application of this technique in an automotive heating, ventilating, and air-conditioning system with HFC134a working fluid has been studied for the purpose of providing supplemental heating for electric vehicles and hybrid electric vehicles by establishing a detailed simulation model of a HP system with the TE heat exchanger. Both the laboratory test and the calculation study show that a VCC with integrated TE modules has both reasonable efficiency and increased heating capacity.

  12. An emulator for testing HVAC-control and energy management systems

    Science.gov (United States)

    Laitila, Paeivi; Kaerki, Satu; Piira, Kalevi; Katajisto, Katri; Kohonen, Reijo

    1992-02-01

    A technical description of an emulator for control and energy systems is presented. The emulator is made up of both physical components and numerical models programmed for a computer. In the emulator, the building and its internal and external heart and moisture loads are numerical models in all cases, if they are included in the system under study. The emulator can be used to study control equipment and energy management systems as well as other devices such as heat producing equipment. This is facilitated by the emulator's physical test equipment, which comprises an exchangeable heat producing device, two separate cooling water systems and their heat exchangers, and the mains water supply. At the heart of the emulator's ADP hardware are two microcomputers linked by an Ethernet line. The TRNSYS simulation software has been installed in one of the microcomputers, and the GENESIS process control program in the other. GENESIS is not needed for running the emulation. The process interface equipment and simulation software are connected to one another via their RS-232 serial ports. The performance functionality of the emulator was tested by investigating the control of an air conditioning system with a commercial controller (substation).

  13. A PID de-tuned method for multivariable systems, applied for HVAC plant

    Science.gov (United States)

    Ghazali, A. B.

    2015-09-01

    A simple yet effective de-tuning of PID parameters for multivariable applications has been described. Although the method is felt to have wider application it is simulated in a 3-input/ 2-output building energy management system (BEMS) with known plant dynamics. The controller performances such as the sum output squared error and total energy consumption when the system is at steady state conditions are studied. This tuning methodology can also be extended to reduce the number of PID controllers as well as the control inputs for specified output references that are necessary for effective results, i.e. with good regulation performances being maintained.

  14. Power System Technical Performance Issues Related to the Application of Long HVAC Cables

    DEFF Research Database (Denmark)

    Bak, Claus Leth

    The aim of this TB is to serve as a practical guide for preparing models and performing studies necessary during the assessment of the technical performance of HV/EHV systems with a large share of (long) AC cables. The brochure follows all phases of planning and analysis of a typical underground...

  15. A new design guideline for the heating and cooling curve in AHU units of HVAC systems

    NARCIS (Netherlands)

    Elkhuizen, P.A.; Peitsman, H.C.; Wienk, W.J.

    2003-01-01

    New Dutch office buildings are built under strict energy efficient legislation and are well equipped with insulation, condensing boilers, heat recovery systems, and so on. Despite this, many buildings do not have good energy efficiency and also do not meet comfort requirements. This has led to a lar

  16. Power System Technical Performance Issues Related to the Application of Long HVAC Cables

    DEFF Research Database (Denmark)

    Bak, Claus Leth

    The aim of this TB is to serve as a practical guide for preparing models and performing studies necessary during the assessment of the technical performance of HV/EHV systems with a large share of (long) AC cables. The brochure follows all phases of planning and analysis of a typical underground ...

  17. Assessing the potential of residential HVAC systems for demand-side management

    NARCIS (Netherlands)

    van der Klauw, Thijs; Hoogsteen, Gerwin; Gerards, Marco Egbertus Theodorus; Hurink, Johann L.; Feng, Xianyong; Hebner, Robert E.

    This paper investigates the potential of residential heating, ventilation and air conditioning systems to contribute to dynamic demand-side management. Thermal models for seven houses in Austin, Texas are developed with the goal of using them in a planning based demand-side management methodology.

  18. A new design guideline for the heating and cooling curve in AHU units of HVAC systems

    NARCIS (Netherlands)

    Elkhuizen, P.A.; Peitsman, H.C.; Wienk, W.J.

    2003-01-01

    New Dutch office buildings are built under strict energy efficient legislation and are well equipped with insulation, condensing boilers, heat recovery systems, and so on. Despite this, many buildings do not have good energy efficiency and also do not meet comfort requirements. This has led to a

  19. Business cases for product configuration systems

    DEFF Research Database (Denmark)

    Shafiee, Sara; Kristjansdottir, Katrin; Hvam, Lars

    to be made in order to secure the success and delivery of the project as it will increase the commitment from the business side. This paper presents a framework for supporting the development of business cases for PCSs and discusses the experiences from multiple case studies benefiting from the suggested......In the recent years, product configuration systems (PCSs) have received greater attention from industries providing customized products as a response to increased demand to fulfil diverse customers’ needs for customized products. Before developing a PCS, a well-established business case has...

  20. An Integrated FDD System for HVAC&R Based on Virtual Sensors

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Woohyun

    2017-01-22

    According to the U.S Department of Energy, space heating, ventilation and air conditioning system account for 40% of residential primary energy use and for 30% of primary energy use in commercial buildings. A study released by the Energy Information Administration indicated that packaged air conditioners are widely used in 46% of all commercial buildings in the U.S. This study indicates that the annual cooling energy consumption related to the packaged air conditioner is about 160 trillion Btus. Therefore, an automated FDD system that can automatically detect and diagnose faults and evaluate fault impacts has the potential for improving energy efficiency along with reducing service costs and comfort complaints. The primary bottlenecks to diagnostic implementation in the field are the high initial costs of additional sensors. To prevent those limitations, virtual sensors with low cost measurements and simple models are developed to estimate quantities that would be expensive and or difficult to measure directly. The use of virtual sensors can reduce costs compared to the use of real sensors and provide additional information for economic assessment. The virtual sensor can be embedded in a permanently installed control or monitoring system and continuous monitoring potentially leads to early detection of faults. The virtual sensors of individual equipment components can be integrated to estimate overall diagnostic information using the output of each virtual sensor.

  1. Central configurations, periodic orbits, and Hamiltonian systems

    CERN Document Server

    Llibre, Jaume; Simó, Carles

    2015-01-01

    The notes of this book originate from three series of lectures given at the Centre de Recerca Matemàtica (CRM) in Barcelona. The first one is dedicated to the study of periodic solutions of autonomous differential systems in Rn via the Averaging Theory and was delivered by Jaume Llibre. The second one, given by Richard Moeckel, focusses on methods for studying Central Configurations. The last one, by Carles Simó, describes the main mechanisms leading to a fairly global description of the dynamics in conservative systems. The book is directed towards graduate students and researchers interested in dynamical systems, in particular in the conservative case, and aims at facilitating the understanding of dynamics of specific models. The results presented and the tools introduced in this book include a large range of applications.

  2. 基于LPNTI-PLC的HVAC系统反馈控制%HVAC System Feedback Control Method Based on LPNTI-PLC Research

    Institute of Scientific and Technical Information of China (English)

    王攀藻; 张华

    2015-01-01

    针对变风量中央空调系统HVAC,频繁工作、多干扰和控制滞后以及被控对象参数未知或是时变的情况,传统的控制方法不能够很好的消除干扰和控制延迟导致系统不能很好地进行反馈调节,控制效果欠佳。提出了基于拉氏正反变换积分PLC的HVAC系统反馈控制方法,该方法在多动态工况下的HVAC系统的应用,能够提高控制精度,根据系统输入、输出变化量阶跃响应,建立LPNTI积分控制模型,只要模型选取合适的参数,就能消除静差和余差,避免饱和超调,而且进一步校正模型的稳定性,使得适应HVAC系统动态工况,同时,基于鲁棒性能指标,控制方法设计了PLC控制模型。实验结果表明,此方法比传统的控制方法更具有优越性,体现了有效性和实用性,对提升HVAC系统的控制精度和响应速度具有较大的帮助。%For HVAC vav central air-conditioning system, frequently, interference and control work lag and the situation of the controlled object parameters are unknown or time-varying, traditional control methods can't eliminate interference and well control delay cause system can't good feedback adjustment, the control effect. And reverse transformation is proposed based on The Laplace integral PLC of The HVAC system feedback control method, The method in The application of dy⁃namic conditions of HVAC system, can improve The control precision, based on The system input and output variation step response, LPNTI integral control model is set up, as long as The model to select The appropriate parameters, can eliminate The static error and residual, avoid saturated overshoot, and further The stability of The calibration model, make to adapt to The HVAC system dynamic condition, at The same time, based on The robust performance index, The control method to de⁃sign The PLC control model. The experimental results show that this method is more superiority than

  3. Model Predictive Control of HVAC Systems: Implementation and Testing at the University of California, Merced

    Energy Technology Data Exchange (ETDEWEB)

    Haves, Phillip; Hencey, Brandon; Borrell, Francesco; Elliot, John; Ma, Yudong; Coffey, Brian; Bengea, Sorin; Wetter, Michael

    2010-06-29

    A Model Predictive Control algorithm was developed for the UC Merced campus chilled water plant. Model predictive control (MPC) is an advanced control technology that has proven successful in the chemical process industry and other industries. The main goal of the research was to demonstrate the practical and commercial viability of MPC for optimization of building energy systems. The control algorithms were developed and implemented in MATLAB, allowing for rapid development, performance, and robustness assessment. The UC Merced chilled water plant includes three water-cooled chillers and a two million gallon chilled water storage tank. The tank is charged during the night to minimize on-peak electricity consumption and take advantage of the lower ambient wet bulb temperature. The control algorithms determined the optimal chilled water plant operation including chilled water supply (CHWS) temperature set-point, condenser water supply (CWS) temperature set-point and the charging start and stop times to minimize a cost function that includes energy consumption and peak electrical demand over a 3-day prediction horizon. A detailed model of the chilled water plant and simplified models of the buildings served by the plant were developed using the equation-based modeling language Modelica. Steady state models of the chillers, cooling towers and pumps were developed, based on manufacturers performance data, and calibrated using measured data collected and archived by the control system. A detailed dynamic model of the chilled water storage tank was also developed and calibrated. Simple, semi-empirical models were developed to predict the temperature and flow rate of the chilled water returning to the plant from the buildings. These models were then combined and simplified for use in a model predictive control algorithm that determines the optimal chiller start and stop times and set-points for the condenser water temperature and the chilled water supply temperature. The

  4. Classroom HVAC: Improving ventilation and saving energy -- field study plan

    Energy Technology Data Exchange (ETDEWEB)

    Apte, Michael G.; Faulkner, David; Hodgson, Alfred T.; Sullivan, Douglas P.

    2004-10-14

    The primary goals of this research effort are to develop, evaluate, and demonstrate a very practical HVAC system for classrooms that consistently provides classrooms (CRs) with the quantity of ventilation in current minimum standards, while saving energy, and reducing HVAC-related noise levels. This research is motivated by the public benefits of energy efficiency, evidence that many CRs are under-ventilated, and public concerns about indoor environmental quality in CRs. This document provides a summary of the detailed plans developed for the field study that will take place in 2005 to evaluate the energy and IAQ performance of a new classroom HVAC technology. The field study will include measurements of HVAC energy use, ventilation rates, and IEQ conditions in 10 classrooms with the new HVAC technology and in six control classrooms with a standard HVAC system. Energy use and many IEQ parameters will be monitored continuously, while other IEQ measurements will be will be performed seasonally. Continuously monitored data will be remotely accessed via a LonWorks network. Instrument calibration plans that vary with the type of instrumentation used are established. Statistical tests will be employed to compare energy use and IEQ conditions with the new and standard HVAC systems. Strengths of this study plan include the collection of real time data for a full school year, the use of high quality instrumentation, the incorporation of many quality control measures, and the extensive collaborations with industry that limit costs to the sponsors.

  5. Solar Trigeneration: a Transitory Simulation of HVAC Systems Using Different Typologies of Hybrid Panels

    Directory of Open Access Journals (Sweden)

    Alejandro del Amo Sancho

    2014-03-01

    Full Text Available The high energy demand on buildings requires efficient installations and the integration of renewable energy to achieve the goal of reducing energy consumption using traditional energy sources. Usually, solar energy generation and heating loads have different profiles along a day and their maximums take place at different moments. In addition, in months in which solar production is higher, the heating demands are the minimum (hot water is consumed only domestically in summer. Cooling machines (absorption and adsorption allow using thermal energy to chill a fluid. This heat flow rate could be recovered from solar collectors or any other heat source. The aim of this study is to integrate different typologies of solar hybrid (photovoltaic and thermal collectors with cooling machines getting solar trigeneration and concluding the optimal combination for building applications. The heat recovered from the photovoltaic module is used to provide energy to these cooling machines getting a double effect: to get a better efficiency on PV modules and to cool the building. In this document the authors analyse these installations, their operating conditions, dimensions and parameters, in order to get the optimal installation in three different European cities. This work suggests that in a family house in Madrid, the optimal combination is to use CPVT with azimuthally tracking and absorption machine. In this case, the solar trigeneration system using 55 m2 of collector area saves the cooling loads and 79% of the heating load in the house round the year.

  6. Configuration Design of Product Service System for CNC Machine Tools

    OpenAIRE

    Zhongqi Sheng; Tao Xu; Junyou Song

    2015-01-01

    Product service system is a combination of product and services to meet the customer requirements. Configuration design is the key process of product service system development. This paper studies the configuration design of product service system for CNC machine tools. The research explores the configuration design process of product service system development, analyzes the retrieval method of product service system schemes, determines the configuration sequence of product modules and servic...

  7. Configuration and Data Management Process and the System Safety Professional

    Science.gov (United States)

    Shivers, Charles Herbert; Parker, Nelson C. (Technical Monitor)

    2001-01-01

    This article presents a discussion of the configuration management (CM) and the Data Management (DM) functions and provides a perspective of the importance of configuration and data management processes to the success of system safety activities. The article addresses the basic requirements of configuration and data management generally based on NASA configuration and data management policies and practices, although the concepts are likely to represent processes of any public or private organization's well-designed configuration and data management program.

  8. Co-simulation for performance prediction of integrated building and HVAC systems - An analysis of solution characteristics using a two-body system

    Energy Technology Data Exchange (ETDEWEB)

    Trcka, Marija; L.M. Hensena, Jan; Wetter, Michael

    2010-06-21

    Integrated performance simulation of buildings and heating, ventilation and airconditioning (HVAC) systems can help reducing energy consumption and increasing occupant comfort. However, no single building performance simulation (BPS) tool offers suffcient capabilities and flexibilities to analyze integrated building systems and to enable rapid prototyping of innovative building and system technologies. One way to alleviate this problem is to use co-simulation to integrate different BPS tools. Co-simulation approach represents a particular case of simulation scenario where at least two simulators solve coupled differential-algebraic systems of equations and exchange data that couples these equations during the time integration. This article analyzes how co-simulation influences consistency, stability and accuracy of the numerical approximation to the solution. Consistency and zero-stability are studied for a general class of the problem, while a detailed consistency and absolute stability analysis is given for a simple two-body problem. Since the accuracy of the numerical approximation to the solution is reduced in co-simulation, the article concludes by discussing ways for how to improve accuracy.

  9. Design principles of a nuclear and industrial HVAC of IFMIF

    Energy Technology Data Exchange (ETDEWEB)

    Pruneri, Giuseppe [IFMIF/EVEDA, Project Team, Rokkasho (Japan); Ibarra, A. [CIEMAT, Madrid (Spain); Heidinger, R. [F4E, Garching (Germany); Knaster, J. [IFMIF/EVEDA Project Team, Rokkasho (Japan); Sugimoto, M. [JAEA, Rokkasho (Japan)

    2016-02-15

    Highlights: • Parameter of Derivate air Contamination (DAC) allows to associate the type of air ventilation. • The construction and operation of IFMIF will be subjected to the regulations of the country in which it will be sited. • Structures, systems and components are assigned a particular safety important components (SIC, 1–2 and Non-SIC) clarification that is based on the consequences of their failure. • Reliability, Availability, Maintainability and Inspectability (RAMI) analysis has given a great contribution of the facility to optimize the configuration, particularly for the HVAC system. - Abstract: In 2013, the IFMIF, the International Fusion Material Irradiation Facility, presently in its Engineering Validation and Engineering Design Activities (EVEDA) phase, framed by the Broader Approach Agreement between Japan and EURATOM, accomplished in 2013 its mandate to provide the engineering design of the plant on schedule [1]. The IFMIF aims to qualify and characterize materials that are capable of withstanding the intense neutron flux originated in D-T reactions of future fusion reactors due to a neutron flux with a broad peak at 14 MeV, which is able to provide >20 dpa/fpy on small specimens in this EVEDA phase. The successful operation of such a challenging plant demands a careful assessment of the Conventional Facilities (CF), which have adequate redundancies to allow for the target plant availability [2]. The present paper addresses the design proposed in the IFMIF Intermediate Engineering Design Report regarding the CF, particularly the IFMIF's Nuclear and Industrial HVAC design. A preliminary feasibility study, including the initial configuration, calculations and reliability/availability analysis, were performed. The nuclear HVAC design was developed progressively; first, by establishing a conceptual design, starting from the system functional description, followed by the identification of the corresponding interfacing systems and their

  10. Microsoft System Center Configuration Manager advanced deployment

    CERN Document Server

    Coupland, Martyn

    2014-01-01

    If you are an experienced Configuration Manager administrator looking to advance your career or get more from your current environment, then this book is ideal for you. Prior experience of deploying and managing a Configuration Manager site would be helpful in following the examples throughout this book.

  11. Configuration of Distributed Message Converter Systems using Performance Modeling

    NARCIS (Netherlands)

    Aberer, Karl; Risse, Thomas; Wombacher, Andreas

    2001-01-01

    To find a configuration of a distributed system satisfying performance goals is a complex search problem that involves many design parameters, like hardware selection, job distribution and process configuration. Performance models are a powerful tools to analyse potential system configurations, howe

  12. Solar PV Energy Conversion System and its Configurations

    OpenAIRE

    Ahteshamul Haque

    2016-01-01

    Solar PV based energy conversion system is now used in commercial and residential buildings. Advancements in Power electronics leads the researchers to enhance the use of solar application in various configurations. These configurations may be used to utilize the energy optimally. The main objective of this paper is to present an overview of the various configurations of solar PV energy conversion system

  13. CRANS - CONFIGURABLE REAL-TIME ANALYSIS SYSTEM

    Science.gov (United States)

    Mccluney, K.

    1994-01-01

    In a real-time environment, the results of changes or failures in a complex, interconnected system need evaluation quickly. Tabulations showing the effects of changes and/or failures of a given item in the system are generally only useful for a single input, and only with regard to that item. Subsequent changes become harder to evaluate as combinations of failures produce a cascade effect. When confronted by multiple indicated failures in the system, it becomes necessary to determine a single cause. In this case, failure tables are not very helpful. CRANS, the Configurable Real-time ANalysis System, can interpret a logic tree, constructed by the user, describing a complex system and determine the effects of changes and failures in it. Items in the tree are related to each other by Boolean operators. The user is then able to change the state of these items (ON/OFF FAILED/UNFAILED). The program then evaluates the logic tree based on these changes and determines any resultant changes to other items in the tree. CRANS can also search for a common cause for multiple item failures, and allow the user to explore the logic tree from within the program. A "help" mode and a reference check provide the user with a means of exploring an item's underlying logic from within the program. A commonality check determines single point failures for an item or group of items. Output is in the form of a user-defined matrix or matrices of colored boxes, each box representing an item or set of items from the logic tree. Input is via mouse selection of the matrix boxes, using the mouse buttons to toggle the state of the item. CRANS is written in C-language and requires the MIT X Window System, Version 11 Revision 4 or Revision 5. It requires 78K of RAM for execution and a three button mouse. It has been successfully implemented on Sun4 workstations running SunOS, HP9000 workstations running HP-UX, and DECstations running ULTRIX. No executable is provided on the distribution medium; however

  14. A Modular Re-configurable Rover System

    Science.gov (United States)

    Bouloubasis, A.; McKee, G.; Active Robotics Lab

    In this paper we present the novel concepts incorporated in a planetary surface exploration rover design that is currently under development. The Multitasking Rover (MTR) aims to demonstrate functionality that will cover many of the current and future needs such as rough-terrain mobility, modularity and upgradeability [1]. The rover system has enhanced mobility characteristics. It operates in conjunction with Science Packs (SPs) and Tool Packs (TPs) - modules attached to the main frame of the rover, which are either special tools or science instruments and alter the operation capabilities of the system. To date, each rover system design is very much task driven for example, the scenario of cooperative transportation of extended payloads [2], comprises two rovers each equipped with a manipulator dedicated to the task [3]. The MTR approach focuses mostly on modularity and upgradeability presenting at the same time a fair amount of internal re-configurability for the sake of rough terrain stability. The rover itself does not carry any scientific instruments or tools. To carry out the scenario mentioned above, the MTR would have to locate and pick-up a TP with the associated manipulator. After the completion of the task the TP could be put away to a storage location enabling the rover to utilize a different Pack. The rover will not only offer mobility to these modules, but also use them as tools, transforming its role and functionality. The advantage of this approach is that instead of sending a large number of rovers to perform a variety of tasks, a smaller number of MTRs could be deployed with a large number of SPs/TPs, offering multiples of the functionality at a reduced payload. Two SPs or TPs (or a combination of) can be carried and deployed. One of the key elements in the design of the four wheeled rover, lies within its suspension system. It comprises a linear actuator located within each leg and also an active differential linking the two shoulders. This novel

  15. Cutting the cost of hospital HVAC.

    Science.gov (United States)

    Ruddell, Steve

    2011-09-01

    Steve Ruddell, head of global marketing, Motors & Generators, at ABB, emphasises the importance of a good motor management and maintenance policy in getting the best performance from, and reducing the energy consumption of, hospitals' HVAC systems, also explaining why investing in energy-efficient, low voltage drives, and high efficiency electric motors, to control such equipment, can pay major dividends for estates and facilities teams.

  16. Evaluating performance indices of a shopping centre and implementing HVAC control principles to minimize energy usage

    OpenAIRE

    Canbay, Çağlar Selçuk; Hepbaşlı, Arif; Gökçen Akkurt, Gülden

    2004-01-01

    Heating, ventilating and air-conditioning (HVAC) systems in buildings must be integrated with an efficient control scheme to maintain comfort under any load conditions. Efficient HVAC control is often the most cost-effective option to improve the energy efficiency of a building. However, HVAC processes are non-linear, and characteristics change on a seasonal basis so the effect of changing the control strategy is usually difficult to predict. The present study aims to reduce energy consumptio...

  17. Automatization of hardware configuration for plasma diagnostic system

    Science.gov (United States)

    Wojenski, A.; Pozniak, K. T.; Kasprowicz, G.; Kolasinski, P.; Krawczyk, R. D.; Zabolotny, W.; Linczuk, P.; Chernyshova, M.; Czarski, T.; Malinowski, K.

    2016-09-01

    Soft X-ray plasma measurement systems are mostly multi-channel, high performance systems. In case of the modular construction it is necessary to perform sophisticated system discovery in parallel with automatic system configuration. In the paper the structure of the modular system designed for tokamak plasma soft X-ray measurements is described. The concept of the system discovery and further automatic configuration is also presented. FCS application (FMC/ FPGA Configuration Software) is used for running sophisticated system setup with automatic verification of proper configuration. In order to provide flexibility of further system configurations (e.g. user setup), common communication interface is also described. The approach presented here is related to the automatic system firmware building presented in previous papers. Modular construction and multichannel measurements are key requirement in term of SXR diagnostics with use of GEM detectors.

  18. Project Phase Dependent Configuration of Project Management Information Systems

    OpenAIRE

    Bērziša, S; Grabis, J.

    2012-01-01

    Project management information systems ensure the collection and display of project information. The project information changes depend upon the project environment. According to project environment and requirements, the configuration of project management information system is ensured by means of an approach to configuration of project management information systems. However, topicality of information and access to it change during the project life cycle depending upo...

  19. Chapter 19: HVAC Controls (DDC/EMS/BAS) Evaluation Protocol

    Energy Technology Data Exchange (ETDEWEB)

    Romberger, J.

    2014-11-01

    The HVAC Controls Evaluation Protocol is designed to address evaluation issues for direct digital controls/energy management systems/building automation systems (DDC/EMS/BAS) that are installed to control heating, ventilation, and air-conditioning (HVAC) equipment in commercial and institutional buildings. (This chapter refers to the DDC/EMS/BAS measure as HVAC controls.) This protocol may also be applicable to industrial facilities such as clean rooms and labs, which have either significant HVAC equipment or spaces requiring special environmental conditions. This protocol addresses only HVAC-related equipment and the energy savings estimation methods associated with installing such control systems as an energy efficiency measure. The affected equipment includes: Air-side equipment (air handlers, direct expansion systems, furnaces, other heating- and cooling-related devices, terminal air distribution equipment, and fans); Central plant equipment (chillers, cooling towers, boilers, and pumps). These controls may also operate or affect other end uses, such as lighting, domestic hot water, irrigation systems, and life safety systems such as fire alarms and other security systems. Considerable nonenergy benefits, such as maintenance scheduling, system component troubleshooting, equipment failure alarms, and increased equipment lifetime, may also be associated with these systems. When connected to building utility meters, these systems can also be valuable demand-limiting control tools. However, this protocol does not evaluate any of these additional capabilities and benefits.

  20. Solar PV Energy Conversion System and its Configurations

    Directory of Open Access Journals (Sweden)

    Ahteshamul Haque

    2016-02-01

    Full Text Available Solar PV based energy conversion system is now used in commercial and residential buildings. Advancements in Power electronics leads the researchers to enhance the use of solar application in various configurations. These configurations may be used to utilize the energy optimally. The main objective of this paper is to present an overview of the various configurations of solar PV energy conversion system

  1. Software control and system configuration management - A process that works

    Science.gov (United States)

    Petersen, K. L.; Flores, C., Jr.

    1983-01-01

    A comprehensive software control and system configuration management process for flight-crucial digital control systems of advanced aircraft has been developed and refined to insure efficient flight system development and safe flight operations. Because of the highly complex interactions among the hardware, software, and system elements of state-of-the-art digital flight control system designs, a systems-wide approach to configuration control and management has been used. Specific procedures are implemented to govern discrepancy reporting and reconciliation, software and hardware change control, systems verification and validation testing, and formal documentation requirements. An active and knowledgeable configuration control board reviews and approves all flight system configuration modifications and revalidation tests. This flexible process has proved effective during the development and flight testing of several research aircraft and remotely piloted research vehicles with digital flight control systems that ranged from relatively simple to highly complex, integrated mechanizations.

  2. Energy-Smart Choices for Schools. An HVAC Comparison Tool. [CD-ROM].

    Science.gov (United States)

    Geothermal Heat Pump Consortium, Inc., Washington, DC.

    A CD ROM program provides comparison construction cost capabilities for heating, ventilation, and air conditioning (HVAC) systems in educational facilities. The program combines multiple types of systems with square footage data on low and high construction cost and school size to automatically calculate HVAC comparative construction costs. (GR)

  3. Energy-Smart Choices for Schools. An HVAC Comparison Tool. [CD-ROM].

    Science.gov (United States)

    Geothermal Heat Pump Consortium, Inc., Washington, DC.

    A CD ROM program provides comparison construction cost capabilities for heating, ventilation, and air conditioning (HVAC) systems in educational facilities. The program combines multiple types of systems with square footage data on low and high construction cost and school size to automatically calculate HVAC comparative construction costs. (GR)

  4. Development of a system for detection and diagnosis of errors in the operation of space HVAC systems; Entwicklung eines Systems zur Erkennung und Diagnose von Fehlern beim Betrieb von HLK-Anlagen

    Energy Technology Data Exchange (ETDEWEB)

    Bach, H.; Bauer, M.; Grob, R.F. [Stuttgart Univ. (Germany). Lehrstuhl fuer Heiz- und Raumlufttechnik

    1997-12-31

    Buildings with heating and space HVAC systems require considerable automatic control effort to ensure engergy-efficient operation. Faults are only to be avoided by the use of automatic fault detection systems. The contribution describes the procedure adopted in operation monitoring, the IKE system for fault detection and diagnosis, and the evaluation of the FDD system. (MSK) [Deutsch] Gebaeude mit heiz-und raumlufttechnischen Anlagen erfordern bei energetisch rationellem Bertrieb einen grossen Aufwand an Steuerungs-und Regelungstechnik. Um ohne Fehler zu arbeiten erfordert diese Steuerungs-und Regelungstechnik den Einsatz von automatischen Fehlererkennungssystemen. Im Folgenden werden die Vorgehensweise bei der Betriebsueberwachung, das IKE-System zur Fehlererkennung und Diagnose sowie die Evaluierung des FDD-Systems (Fault Detection and Diagnosis System) erlaeutert.

  5. Product Configuration Systems - Implications for Product Innovation and Development

    DEFF Research Database (Denmark)

    Edwards, Kasper; Pedersen, Jørgen Lindgaard

    2004-01-01

    configurations. However, costs are but one parameter on which firms compete and firms must continually innovate new and develop existing products. This paper presents original empirical insights on implementation and use of product configuration systems in a number of Danish industrial firms. The paper discusses...... the organisational changes associated with PCS and how this affects product innovation and development. The paper begins by introducing product configuration systems, which are then placed in context to the firm as a process technology which coordinate different processes: product development, order acquisition......Product Configuration Systems (PCS) is a step in the direction of mass customization in the sense that PCS allows a firm to significantly lower the unit cost of configuration. Thus PCS is a valuable technology for lowering operating costs while retaining a high number of possible product...

  6. Relating binary-star planetary systems to central configurations

    CERN Document Server

    Veras, Dimitri

    2016-01-01

    Binary-star exoplanetary systems are now known to be common, for both wide and close binaries. However, their orbital evolution is generally unsolvable. Special cases of the N-body problem which are in fact completely solvable include dynamical architectures known as central configurations. Here, I utilize recent advances in our knowledge of central configurations to assess the plausibility of linking them to coplanar exoplanetary binary systems. By simply restricting constituent masses to be within stellar or substellar ranges characteristic of planetary systems, I find that (i) this constraint reduces by over 90 per cent the phase space in which central configurations may occur, (ii) both equal-mass and unequal-mass binary stars admit central configurations, (iii) these configurations effectively represent different geometrical extensions of the Sun-Jupiter-Trojan-like architecture, (iv) deviations from these geometries are no greater than ten degrees, and (v) the deviation increases as the substellar masse...

  7. The HVAC Control Technology Making Energy Saving Compatible with Comfort

    Science.gov (United States)

    Takagi, Yasuo; Yonezawa, Kenzo; Murayama, Dai; Nishimura, Nobutaka; Hanada, Yuuichi; Yamazaki, Kenichi

    The new air-conditioning control technology for the energy saving for buildings is proposed. The method is mainly focused on the compatibility of energy savings and comfort. The energy saving is achieved through the next generation air handling unit that controls room humidity without energy loss and the optimal operation of HVAC (Heating, Ventilating and air-conditioning) system, manipulating the supplying airflow temperature to the rooms, room temperature and the humidity. The comfort is kept by the index (PMV: Predicted Mean Vote) that calculated with room temperature, humidity, radiation temperature, wind velocity and so on. In order to find the HVAC system operation conditions that satisfy the comfort and energy saving at the same time, very large-scale nonlinear programming with nonlinear constraints must be solved on real time basis. To make the programming of the system practical, the driving function loaded onto a control computer is introduced. The function is made by the spline interpolation to achieve calculation stable and to adapt to various HVAC operation modes. The effectiveness of the HVAC control technology is proved through a building HVAC data and the simulations using the data.

  8. Observation-Driven Configuration of Complex Software Systems

    CERN Document Server

    Sage, Aled

    2010-01-01

    The ever-increasing complexity of software systems makes them hard to comprehend, predict and tune due to emergent properties and non-deterministic behaviour. Complexity arises from the size of software systems and the wide variety of possible operating environments: the increasing choice of platforms and communication policies leads to ever more complex performance characteristics. In addition, software systems exhibit different behaviour under different workloads. Many software systems are designed to be configurable so that policies can be chosen to meet the needs of various stakeholders. For complex software systems it can be difficult to accurately predict the effects of a change and to know which configuration is most appropriate. This thesis demonstrates that it is useful to run automated experiments that measure a selection of system configurations. Experiments can find configurations that meet the stakeholders' needs, find interesting behavioural characteristics, and help produce predictive models of...

  9. Tank monitor and control system (TMACS) software configuration management plan

    Energy Technology Data Exchange (ETDEWEB)

    GLASSCOCK, J.A.

    1999-05-13

    This Software Configuration Management Plan (SCMP) describes the methodology for control of computer software developed and supported by the Systems Development and Integration (SD and I) organization of Lockheed Martin Services, Inc. (LMSI) for the Tank Monitor and Control System (TMACS). This plan controls changes to the software and configuration files used by TMACS. The controlled software includes the Gensym software package, Gensym knowledge base files developed for TMACS, C-language programs used by TMACS, the operating system on the production machine, language compilers, and all Windows NT commands and functions which affect the operating environment. The configuration files controlled include the files downloaded to the Acromag and Westronic field instruments.

  10. Building America Top Innovations 2014 Profile: HVAC Cabinet Air Leakage Test Method

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2014-11-01

    This 2014 Top Innovation profile describes Building America-funded research by teams and national laboratories that resulted in the development of an ASHRAE standard and a standardized testing method for testing the air leakage of HVAC air handlers and furnace cabinets and has spurred equipment manufacturers to tighten the cabinets they use for residential HVAC systems.

  11. An Implementation of a Network Configuration Management System ...

    African Journals Online (AJOL)

    An Implementation of a Network Configuration Management System Using Mobile Agent. ... The job of the network administrator becomes difficult as the number of hosts in a computer network increase. Network management ... Article Metrics.

  12. Active noise control: A tutorial for HVAC designers

    Energy Technology Data Exchange (ETDEWEB)

    Gelin, L.J.

    1997-08-01

    This article will identify the capabilities and limitations of ANC in its application to HVAC noise control. ANC can be used in ducted HVAC systems to cancel ductborne, low-frequency fan noise by injecting sound waves of equal amplitude and opposite phase into an air duct, as close as possible to the source of the unwanted noise. Destructive interference of the fan noise and injected noise results in sound cancellation. The noise problems that it solves are typically described as rumble, roar or throb, all of which are difficult to address using traditional noise control methods. This article will also contrast the use of active against passive noise control techniques. The main differences between the two noise control measures are acoustic performance, energy consumption, and design flexibility. The article will first present the fundamentals and basic physics of ANC. The application to real HVAC systems will follow.

  13. Job Prospects in HVAC Engineering.

    Science.gov (United States)

    Basta, Nicholas

    1985-01-01

    Although heating, ventilation, and air conditioning (HVAC) engineering degrees are not offered, there is a serious need for specialists and consultants in this area (since most have been trained as mechanical engineers). Opportunities exist for individuals possessing a customer-oriented attitude, with knowledge in computerized controls, innovative…

  14. Job Prospects in HVAC Engineering.

    Science.gov (United States)

    Basta, Nicholas

    1985-01-01

    Although heating, ventilation, and air conditioning (HVAC) engineering degrees are not offered, there is a serious need for specialists and consultants in this area (since most have been trained as mechanical engineers). Opportunities exist for individuals possessing a customer-oriented attitude, with knowledge in computerized controls, innovative…

  15. Project B610 process control configuration acceptance test procedure

    Energy Technology Data Exchange (ETDEWEB)

    Silvan, G.R.

    1994-09-20

    The purpose of this test is to verify the Westinghouse configuration of the MICON A/S Distributed Control System for project B610. The following will be verified: proper assignment and operation of all field inputs to and outputs from the MICON Termination panels; proper operation of all display data on the operator`s console; proper operation of all required alarms; and proper operation of all required interlocks. The MICON A/S control system is configured to replace all the control, indication, and alarm panels now located in the Power Control Room. Nine systems are covered by this control configuration, 2736-ZB HVAC, 234-5Z HVAC, Process Vacuum, Dry Air, 291-Z Closed Loop Cooling, Building Accelerometer, Evacuation Siren, Stack CAMs, and Fire. The 2736-ZB HVAC system consists of the ventilation controls for 2736-ZB and 2736-Z as well as alarms for the emergency generators and 232-Z. The 234-5Z HVAC system is the ventilation controls for 235-5Z and 236-Z buildings. Process Vacuum covers the controls for the 26 inch vacuum system. Dry Air covers the controls for the steam and electric air dryers. The 291-Z Closed Loop Cooling system consists of the status indications and alarms for the 291-Z compressor and vacuum pump closed loop cooling system. The rest of closed loop cooling was tested earlier. The Building Accelerometer system consists of the status indications for the two seismic system accelerometers. The Evacuation Siren system includes the controls for the evacuation and take cover sirens. Stack CAMs cover the alarms for the various building ventilation stack continuous air monitors. Finally, the Fire system covers the various fire alarms now located in Room 321-A.

  16. Product configuration of infra structure systems for data centres

    DEFF Research Database (Denmark)

    Hvam, Lars; Christensen, Tim Teglgaard; Jensen, Søren Brogaard

    2007-01-01

    This article describes how American Power Conversion (APC), a company in the electronics industry, has used product configuration systems as a central part of the company’s mass customisation strategy. APC sells, designs, produce, delivers, and installs large complex infrastructure systems for data...... centres, and components and systems for these systems. At the heart of its mass customisation strategy are a module-based product range and the use of product configuration systems for sales and order processing. In addition, the company has implemented a manufacturing concept, which involves the mass...... to 16 days. Also, production costs were significantly reduced. The use of product configuration systems also supports a widely distributed process of selling APC’s products via more than 10,000 sales associates and dealers worldwide. At the same time, the company’s capability for introducing new...

  17. Measure Guideline: Optimizing the Configuration of Flexible Duct Junction Boxes

    Energy Technology Data Exchange (ETDEWEB)

    Beach, R.; Burdick, A.

    2014-03-01

    This measure guideline offers additional recommendations to heating, ventilation, and air conditioning (HVAC) system designers for optimizing flexible duct, constant-volume HVAC systems using junction boxes within Air Conditioning Contractors of America (ACCA) Manual D guidance (Rutkowski, H. Manual D -- Residential Duct Systems, 3rd edition, Version 1.00. Arlington, VA: Air Conditioning Contractors of America, 2009.). IBACOS used computational fluid dynamics software to explore and develop guidance to better control the airflow effects of factors that may impact pressure losses within junction boxes among various design configurations (Beach, R., Prahl, D., and Lange, R. CFD Analysis of Flexible Duct Junction Box Design. Golden, CO: National Renewable Energy Laboratory, submitted for publication 2013). These recommendations can help to ensure that a system aligns more closely with the design and the occupants' comfort expectations. Specifically, the recommendations described herein show how to configure a rectangular box with four outlets, a triangular box with three outlets, metal wyes with two outlets, and multiple configurations for more than four outlets. Designers of HVAC systems, contractors who are fabricating junction boxes on site, and anyone using the ACCA Manual D process for sizing duct runs will find this measure guideline invaluable for more accurately minimizing pressure losses when using junction boxes with flexible ducts.

  18. Software configuration management plan for HANDI 2000 business management system

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, D.

    1998-08-25

    The Software Configuration Management Plan (SCMP) describes the configuration management and control environment for HANDI 2000 for the PP and PS software as well as any custom developed software. This plan establishes requirements and processes for uniform documentation control, system change control, systematic evaluation and coordination of HANDI 2000. This SCMP becomes effective as this document is acceptance and will provide guidance through implementation efforts.

  19. Multiyear Plan for Validation of EnergyPlus Multi-Zone HVAC System Modeling using ORNL's Flexible Research Platform

    Energy Technology Data Exchange (ETDEWEB)

    Im, Piljae [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bhandari, Mahabir S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); New, Joshua Ryan [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-10-01

    This document describes the Oak Ridge National Laboratory (ORNL) multiyear experimental plan for validation and uncertainty characterization of whole-building energy simulation for a multi-zone research facility using a traditional rooftop unit (RTU) as a baseline heating, ventilating, and air conditioning (HVAC) system. The project’s overarching objective is to increase the accuracy of energy simulation tools by enabling empirical validation of key inputs and algorithms. Doing so is required to inform the design of increasingly integrated building systems and to enable accountability for performance gaps between design and operation of a building. The project will produce documented data sets that can be used to validate key functionality in different energy simulation tools and to identify errors and inadequate assumptions in simulation engines so that developers can correct them. ASHRAE Standard 140, Method of Test for the Evaluation of Building Energy Analysis Computer Programs (ASHRAE 2004), currently consists primarily of tests to compare different simulation programs with one another. This project will generate sets of measured data to enable empirical validation, incorporate these test data sets in an extended version of Standard 140, and apply these tests to the Department of Energy’s (DOE) EnergyPlus software (EnergyPlus 2016) to initiate the correction of any significant deficiencies. The fitness-for-purpose of the key algorithms in EnergyPlus will be established and demonstrated, and vendors of other simulation programs will be able to demonstrate the validity of their products. The data set will be equally applicable to validation of other simulation engines as well.

  20. Measure Guideline: Optimizing the Configuration of Flexible Duct Junction Boxes

    Energy Technology Data Exchange (ETDEWEB)

    Beach, R. [IBACOS, Inc., Pittsburgh, PA (United States); Burdick, A. [IBACOS, Inc., Pittsburgh, PA (United States)

    2014-03-01

    This measure guideline offers additional recommendations to heating, ventilation, and air conditioning (HVAC) system designers for optimizing flexible duct, constant-volume HVAC systems using junction boxes within Air Conditioning Contractors of America (ACCA) Manual D guidance. IBACOS used computational fluid dynamics software to explore and develop guidance to better control the airflow effects of factors that may impact pressure losses within junction boxes among various design configurations. These recommendations can help to ensure that a system aligns more closely with the design and the occupants' comfort expectations. Specifically, the recommendations described herein show how to configure a rectangular box with four outlets, a triangular box with three outlets, metal wyes with two outlets, and multiple configurations for more than four outlets. Designers of HVAC systems, contractors who are fabricating junction boxes on site, and anyone using the ACCA Manual D process for sizing duct runs will find this measure guideline invaluable for more accurately minimizing pressure losses when using junction boxes with flexible ducts.

  1. Relating binary-star planetary systems to central configurations

    Science.gov (United States)

    Veras, Dimitri

    2016-11-01

    Binary-star exoplanetary systems are now known to be common, for both wide and close binaries. However, their orbital evolution is generally unsolvable. Special cases of the N-body problem which are in fact completely solvable include dynamical architectures known as central configurations. Here, I utilize recent advances in our knowledge of central configurations to assess the plausibility of linking them to coplanar exoplanetary binary systems. By simply restricting constituent masses to be within stellar or substellar ranges characteristic of planetary systems, I find that (i) this constraint reduces by over 90 per cent the phase space in which central configurations may occur, (ii) both equal-mass and unequal-mass binary stars admit central configurations, (iii) these configurations effectively represent different geometrical extensions of the Sun-Jupiter-Trojan-like architecture, (iv) deviations from these geometries are no greater than 10°, and (v) the deviation increases as the substellar masses increase. This study may help restrict future stability analyses to architectures which resemble exoplanetary systems, and might hint at where observers may discover dust, asteroids and/or planets in binary-star systems.

  2. Analysis and control of the effects of over excitation limiters on the stability of the Itaipu HVAC transmission system

    Energy Technology Data Exchange (ETDEWEB)

    Jardim, J.L.; Macedo, N.J.; Santo, S.E.; Praca, A.S. [FURNAS Centrais Eletricas S.A., Rio de Janeiro, RJ (Brazil)

    1994-12-31

    The effect of over excitation limiters on power system voltage stability is presented in this paper. A linear analysis based on system eigenvalues for various operating conditions shows that voltage collapse is essentially a dynamic phenomenon. Time simulations using digital tools and real-time simulator were performed to verify lin ear results and study large disturbances. A control system designed to keep system in secure region is proposed. (author) 3 refs., 9 figs.

  3. Product configuration of infra structure systems for data centres

    DEFF Research Database (Denmark)

    Hvam, Lars; Christensen, Tim Teglgaard; Jensen, Søren Brogaard

    2007-01-01

    This article describes how American Power Conversion (APC), a company in the electronics industry, has used product configuration systems as a central part of the company’s mass customisation strategy. APC sells, designs, produce, delivers, and installs large complex infrastructure systems for data...... centres, and components and systems for these systems. At the heart of its mass customisation strategy are a module-based product range and the use of product configuration systems for sales and order processing. In addition, the company has implemented a manufacturing concept, which involves the mass...... production of standard components in the Far East, and customer order-based final assembly at various production sites around the world within close customer proximity. The results of applying mass customisation principles include a reduction of the overall delivery time for a complete system from around 400...

  4. Data base management system configuration specification. [computer storage devices

    Science.gov (United States)

    Neiers, J. W.

    1979-01-01

    The functional requirements and the configuration of the data base management system are described. Techniques and technology which will enable more efficient and timely transfer of useful data from the sensor to the user, extraction of information by the user, and exchange of information among the users are demonstrated.

  5. An approach for the development of visual configuration systems

    DEFF Research Database (Denmark)

    Hvam, Lars; Ladeby, Klaes Rohde

    2007-01-01

    by Centre for Product Modelling (CPM) at The Technical University of Denmark. The approach is based on experiences from a visualization project in co-operation between CPM and the global provider of power protection American Power Conversion (APC). The visual configuration system was developed in 2001...

  6. The stable configuration in acyclic preference-based systems

    CERN Document Server

    Mathieu, Fabien; Reynier, Julien

    2008-01-01

    Acyclic preferences recently appeared as an elegant way to model many distributed systems. An acyclic instance admits a unique stable configuration, which can reveal the performance of the system. In this paper, we give the statistical properties of the stable configuration for three classes of acyclic preferences: node-based preferences, distance-based preferences, and random acyclic systems. Using random overlay graphs, we prove using mean-field and fluid-limit techniques that these systems have an asymptotically continuous independent rank distribution for a proper scaling, and the analytical solution is compared to simulations. These results provide a theoretical ground for validating the performance of bandwidth-based or proximity-based unstructured systems.

  7. The Role of Configurational Entropy in Amorphous Systems

    Directory of Open Access Journals (Sweden)

    Kirsten A. Graeser

    2010-05-01

    Full Text Available Configurational entropy is an important parameter in amorphous systems. It is involved in the thermodynamic considerations, plays an important role in the molecular mobility calculations through its appearance in the Adam-Gibbs equation and provides information on the solubility increase of an amorphous form compared to its crystalline counterpart. This paper presents a calorimetric method which enables the scientist to quickly determine the values for the configurational entropy at any temperature and obtain the maximum of information from these measurements.

  8. "暖通空调工程设计方法与系统分析"课程教学方法探讨%Discussion on"HVAC Engineering Design and System Analysis"Teaching Method

    Institute of Scientific and Technical Information of China (English)

    夏燚

    2015-01-01

    本文用"思维导图"梳理暖通空调工程设计课程与专业基础课的内在联系,提出用"工科思维"模式学习该课程,把专业基础课的"知识线"构织成该课程的"知识网".本文用"暖通空调工程设计过程图"帮助学生从全局上掌握该"知识网",采用"案例教学"帮助学生掌握暖通空调工程设计技能,帮助学生实现由专业知识向解决工程问题专业技能的转变,从而达到本课程的教学目的.%In this paper, we use"the mind map"to comb the relationship between the course of"HVAC engineering de-sign method and system analysis"and the specialized basic course. The"engineering thinking mode"is put forward to study the course, and use the"knowledge line"of the specialized basic course to construct the"knowledge network". We use the"HVAC engineering design flowchart"to help students master the"knowledge network"from the global, using"the case teaching method"to help students master the skills of HVAC design to help students realize the transformation from knowledge to skills, so as to achieve the purpose of teaching the course.

  9. Particle loading rates for HVAC filters, heat exchangers, and ducts.

    Science.gov (United States)

    Waring, M S; Siegel, J A

    2008-06-01

    The rate at which airborne particulate matter deposits onto heating, ventilation, and air-conditioning (HVAC) components is important from both indoor air quality (IAQ) and energy perspectives. This modeling study predicts size-resolved particle mass loading rates for residential and commercial filters, heat exchangers (i.e. coils), and supply and return ducts. A parametric analysis evaluated the impact of different outdoor particle distributions, indoor emission sources, HVAC airflows, filtration efficiencies, coils, and duct system complexities. The median predicted residential and commercial loading rates were 2.97 and 130 g/m(2) month for the filter loading rates, 0.756 and 4.35 g/m(2) month for the coil loading rates, 0.0051 and 1.00 g/month for the supply duct loading rates, and 0.262 g/month for the commercial return duct loading rates. Loading rates are more dependent on outdoor particle distributions, indoor sources, HVAC operation strategy, and filtration than other considered parameters. The results presented herein, once validated, can be used to estimate filter changing and coil cleaning schedules, energy implications of filter and coil loading, and IAQ impacts associated with deposited particles. The results in this paper suggest important factors that lead to particle deposition on HVAC components in residential and commercial buildings. This knowledge informs the development and comparison of control strategies to limit particle deposition. The predicted mass loading rates allow for the assessment of pressure drop and indoor air quality consequences that result from particle mass loading onto HVAC system components.

  10. Dynamical Configurations of Celestial Systems Comprised of Multiple Irregular Bodies

    CERN Document Server

    Jiang, Yu; Baoyin, Hexi; Li, Junfeng

    2016-01-01

    This manuscript considers the main features of the nonlinear dynamics of multiple irregular celestial body systems. The gravitational potential, static electric potential, and magnetic potential are considered. Based on the three established potentials, we show that three conservative values exist for this system, including a Jacobi integral. The equilibrium conditions for the system are derived and their stability analyzed. The equilibrium conditions of a celestial system comprised of n irregular bodies are reduced to 12n minus 9 equations. The dynamical results are applied to simulate the motion of multiple-asteroid systems. The simulation is useful for the study of the stability of multiple irregular celestial body systems and for the design of spacecraft orbits to triple asteroid systems discovered in the solar system. The dynamical configurations of the five triple-asteroid systems 45 Eugenia, 87 Sylvia, 93 Minerva, 216 Kleopatra, and 136617 1994CC, and the six-body system 134340 Pluto are calculated and...

  11. Air conditioning and energy conservation. Improved space HVAC systems. Case studies: Office buildings, hotels, shopping centers, skyscrapers, industrial plants

    Energy Technology Data Exchange (ETDEWEB)

    Heiner, H.

    1988-08-01

    Rising energy prices and an increasing demand for comfortable rooms account for the importance attached to the windows and glass used for office buildings, hotels and industrial plants. Both windows and glass have a considerable influence on the thermal behavior and air conditioning of buildings. Among the latest developments are precious metal-coated insulating panes. Selected gases allow to reduce the total thickness of insulating glass and improve noise insulation. The case studies presented refer to the energy-saving air conditioning and space heating, heat recovery and cooling of rooms as well as to the respective control systems. Investigations into the specific energy consumption of building shells reveal the considerable space/tap water heating energy conservation potentials remaining to be utilized.

  12. Workplace Trends In HVAC/R

    Science.gov (United States)

    Strang, Lynn; Todd, CeCe

    2013-01-01

    This article presents trends in the heating, ventilation, air conditioning and refrigeration (HVAC/R) industry, with an emphasis on the importance of technician training programs as exemplified at the East Valley Institute of Technology (EVIT) in Mesa, Arizona. The article states that HVAC workers are increasingly helping their consumers "go…

  13. Workplace Trends In HVAC/R

    Science.gov (United States)

    Strang, Lynn; Todd, CeCe

    2013-01-01

    This article presents trends in the heating, ventilation, air conditioning and refrigeration (HVAC/R) industry, with an emphasis on the importance of technician training programs as exemplified at the East Valley Institute of Technology (EVIT) in Mesa, Arizona. The article states that HVAC workers are increasingly helping their consumers "go…

  14. A Configurable, Object-Oriented, Transportation System Software Framework

    Energy Technology Data Exchange (ETDEWEB)

    KELLY,SUZANNE M.; MYRE,JOHN W.; PRICE,MARK H.; RUSSELL,ERIC D.; SCOTT,DAN W.

    2000-08-01

    The Transportation Surety Center, 6300, has been conducting continuing research into and development of information systems for the Configurable Transportation Security and Information Management System (CTSS) project, an Object-Oriented Framework approach that uses Component-Based Software Development to facilitate rapid deployment of new systems while improving software cost containment, development reliability, compatibility, and extensibility. The direction has been to develop a Fleet Management System (FMS) framework using object-oriented technology. The goal for the current development is to provide a software and hardware environment that will demonstrate and support object-oriented development commonly in the FMS Central Command Center and Vehicle domains.

  15. Mathematical optimization of matter distribution for a planetary system configuration

    Science.gov (United States)

    Morozov, Yegor; Bukhtoyarov, Mikhail

    2016-07-01

    Planetary formation is mostly a random process. When the humanity reaches the point when it can transform planetary systems for the purpose of interstellar life expansion, the optimal distribution of matter in a planetary system will determine its population and expansive potential. Maximization of the planetary system carrying capacity and its potential for the interstellar life expansion depends on planetary sizes, orbits, rotation, chemical composition and other vital parameters. The distribution of planetesimals to achieve maximal carrying capacity of the planets during their life cycle, and maximal potential to inhabit other planetary systems must be calculated comprehensively. Moving much material from one planetary system to another is uneconomic because of the high amounts of energy and time required. Terraforming of the particular planets before the whole planetary system is configured might drastically decrease the potential habitability the whole system. Thus a planetary system is the basic unit for calculations to sustain maximal overall population and expand further. The mathematical model of optimization of matter distribution for a planetary system configuration includes the input observed parameters: the map of material orbiting in the planetary system with specified orbits, masses, sizes, and the chemical compound for each, and the optimized output parameters. The optimized output parameters are sizes, masses, the number of planets, their chemical compound, and masses of the satellites required to make tidal forces. Also the magnetic fields and planetary rotations are crucial, but they will be considered in further versions of this model. The optimization criteria is the maximal carrying capacity plus maximal expansive potential of the planetary system. The maximal carrying capacity means the availability of essential life ingredients on the planetary surface, and the maximal expansive potential means availability of uranium and metals to build

  16. Impact of the duct static pressure reset control strategy on the energy consumption by the HVAC system

    Directory of Open Access Journals (Sweden)

    Walaszczyk Juliusz

    2017-01-01

    Full Text Available This article addresses different duct static pressure control strategies which could be implemented in variable air volume air-conditioning systems (VAV. Two pressure reset control strategies are compared to the commonly used control solution based on the “Constant static pressure” method. First pressure reset control strategy, known as PID Control, uses signals from VAV boxes controllers to reset duct static pressure in a way that one of the VAV dampers is maintained almost entirely open. Second strategy decreases static pressure setpoint until an adjustable number of pressure requests occur. As a response to the certain amount of requests, static pressure setpoint is increased. This strategy is called Trim & Respond. Both static pressure reset control strategies described in this paper are considered to have more significant potential for energy savings than the “Constant static pressure” method. In order to validate this potential, several simulations for different control strategies were carried out and the obtained results are compared and analysed. The theoretical limit of the energy savings - set of the optimal control actions, was estimated with Nelder-Mead algorithm and also presented in this article. General description of the static pressure control strategies "Constant static pressure", PID Control and Trim & Respond is given.

  17. Novel Methods for Activity Classification and Occupany Prediction Enabling Fine-grained HVAC Control

    OpenAIRE

    Rana, Rajib; Kusy, Brano; Wall, Josh; Hu, Wen

    2014-01-01

    Much of the energy consumption in buildings is due to HVAC systems, which has motivated several recent studies on making these systems more energy- efficient. Occupancy and activity are two important aspects, which need to be correctly estimated for optimal HVAC control. However, state-of-the-art methods to estimate occupancy and classify activity require infrastructure and/or wearable sensors which suffers from lower acceptability due to higher cost. Encouragingly, with the advancement of th...

  18. SEED: Public Energy and Environment Dataset for Optimizing HVAC Operation in Subway Stations

    OpenAIRE

    Wang, Yongcai; Feng, Haoran; Qi, Xiao

    2013-01-01

    For sustainability and energy saving, the problem to optimize the control of heating, ventilating, and air-conditioning (HVAC) systems has attracted great attentions, but analyzing the signatures of thermal environments and HVAC systems and the evaluation of the optimization policies has encountered inefficiency and inconvenient problems due to the lack of public dataset. In this paper, we present the Subway station Energy and Environment Dataset (SEED), which was collected from a line of Bei...

  19. Artificial immune system algorithm in VLSI circuit configuration

    Science.gov (United States)

    Mansor, Mohd. Asyraf; Sathasivam, Saratha; Kasihmuddin, Mohd Shareduwan Mohd

    2017-08-01

    In artificial intelligence, the artificial immune system is a robust bio-inspired heuristic method, extensively used in solving many constraint optimization problems, anomaly detection, and pattern recognition. This paper discusses the implementation and performance of artificial immune system (AIS) algorithm integrated with Hopfield neural networks for VLSI circuit configuration based on 3-Satisfiability problems. Specifically, we emphasized on the clonal selection technique in our binary artificial immune system algorithm. We restrict our logic construction to 3-Satisfiability (3-SAT) clauses in order to outfit with the transistor configuration in VLSI circuit. The core impetus of this research is to find an ideal hybrid model to assist in the VLSI circuit configuration. In this paper, we compared the artificial immune system (AIS) algorithm (HNN-3SATAIS) with the brute force algorithm incorporated with Hopfield neural network (HNN-3SATBF). Microsoft Visual C++ 2013 was used as a platform for training, simulating and validating the performances of the proposed network. The results depict that the HNN-3SATAIS outperformed HNN-3SATBF in terms of circuit accuracy and CPU time. Thus, HNN-3SATAIS can be used to detect an early error in the VLSI circuit design.

  20. Air filtration in HVAC systems

    CERN Document Server

    Ginestet, Alain; Tronville, Paolo; Hyttinen, Marko

    2010-01-01

    Air filtration Guidebook will help the designer and user to understand the background and criteria for air filtration, how to select air filters and avoid problems associated with hygienic and other conditions at operation of air filters. The selection of air filters is based on external conditions such as levels of existing pollutants, indoor air quality and energy efficiency requirements.

  1. Energy-efficient HVAC design an essential guide for sustainable building

    CERN Document Server

    Khazaii, Javad

    2014-01-01

    This book provides readers with essential knowledge enabling the successful design of today's new energy efficient HVAC systems. The author introduces important concepts such as Knowledge Categorization, Performance Based Design Standards, and Quantification of Uncertainty in Energy Modeling for Buildings. Pivotal topics that all HVAC and architectural engineers must master in order to navigate the green building renaissance are given focused attention, including the role of renewables, air quality, automatic controls, and thermal comfort. Relevant ASHRAE standards, as well as sustainability s

  2. Active Probing Feedback based Self Configurable Intelligent Distributed Antenna System

    DEFF Research Database (Denmark)

    Kumar, Ambuj

    challenge through a viable solution that is based on injecting intelligence and services in parallel layers through a Distributed Antenna Systems (DAS) network. This approach would enable the remote sites to acquire intelligence and a resource pool at the same time, thereby managing the network dynamics...... as Self Configurable Distributed Antenna System (SCIDAS)....... collectively as Place Time Coverage & Capacity (PTC2). The dissertation proves through the concept of the PTC2 that the network performance can severely be degraded by the excessive and unrealistic site demands, the network management inefficiency, and the consequence of the accumulation of subscribers...

  3. Jet Engine Nozzle Exit Configurations and Associated Systems and Methods

    Science.gov (United States)

    Mengle, Vinod G. (Inventor)

    2013-01-01

    Nozzle exit configurations and associated systems and methods are disclosed. An aircraft system in accordance with one embodiment includes a jet engine exhaust nozzle having an internal flow surface and an exit aperture, with the exit aperture having a perimeter that includes multiple projections extending in an aft direction. Aft portions of individual neighboring projections are spaced apart from each other by a gap, and a geometric feature of the multiple can change in a monotonic manner along at least a portion of the perimeter.

  4. Product Configuration Systems and Consequences for Productivity and Quality

    DEFF Research Database (Denmark)

    Pedersen, Jørgen Lindgaard; Edwards, Kasper

    2004-01-01

    Product Configuration Systems (PCS) are systems to produce quotations to potential buyers of the products an enterprise produces. Typically the products are complex and will first be produced according to specific needs from the customers. From twelve case studies in Danish industry...... with informations about expected and realised costs and benefits in implemented PCS's we have the following results: the three highest aggregated scoring expected benefits are: 1)improved quality in specifications, 2)lower turnaround time, and 3)using less resources.The results achieved are in accordance...

  5. HVAC (heating, ventilation, air conditioning) literature in Japan: A critical review

    Energy Technology Data Exchange (ETDEWEB)

    Hane, G.J.

    1988-02-01

    Japanese businessmen in the heating, ventilation, air conditioning, and refrigeration (HVACandR) industry consider the monitoring of technical and market developments in the United States to be a normal part of their business. In contrast, efforts by US businessmen to monitor Japanese HVAC and R developments are poorly developed. To begin to redress this imbalance, this report establishes the groundwork for a more effective system for use in monitoring Japanese HVAC and R literature. Discussions of a review of the principal HVAC and R publications in Japan and descriptions of the type of information contained in each of those publications are included in this report. Since the Japanese HVAC and R literature is abundant, this report also provides practical suggestions on how a researcher or research manager can limit the monitoring effort to the publications and type of information that would most likely be of greatest value.

  6. Impact of HVAC control improvements on supermarket humidity levels

    Energy Technology Data Exchange (ETDEWEB)

    Khattar, M.; Henderson, H.I. Jr.

    1999-07-01

    This paper presents field-monitored data from two supermarkets where the impact of implementing minor HVAC control improvements was evaluated. The control improvements were intended to increase the dehumidification capacity of the HVAC system and lower space humidity levels. Direct digital control (DDC) was installed at each store to monitor system performance and implement the control improvements. At the first test store, a 33,400 ft{sup 2} (3,104 m{sup 2}) supermarket near Minneapolis, a conventional 50 ton (176 kW) split system conditioned the sales area. At the second store, a 50,000 ft{sup 2} (4,647 m{sup 2}{minus}) supermarket near Indianapolis, three rooftop units (RTUs) with a total capacity of 98 tons (344 kW) conditioned the store. The results from both supermarkets confirm the impact that supply airflow and part-load control of evaporator coil temperatures can have on dehumidification performance. Seemingly minor control adjustments can often have a big impact on the performance of supermarket HVAC systems. Even enhanced dehumidification technologies, such as heat pipe-assisted evaporator coils, can benefit from minor system tuning.

  7. Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Liping; Hong, Tianzhen

    2013-01-01

    Almost half of the total energy used in the U.S. buildings is consumed by heating, ventilation and air conditionings (HVAC) according to EIA statistics. Among various driving factors to energy performance of building, operations and maintenance play a significant role. Many researches have been done to look at design efficiencies and operational controls for improving energy performance of buildings, but very few study the impacts of HVAC systems maintenance. Different practices of HVAC system maintenance can result in substantial differences in building energy use. If a piece of HVAC equipment is not well maintained, its performance will degrade. If sensors used for control purpose are not calibrated, not only building energy usage could be dramatically increased, but also mechanical systems may not be able to satisfy indoor thermal comfort. Properly maintained HVAC systems can operate efficiently, improve occupant comfort, and prolong equipment service life. In the paper, maintenance practices for HVAC systems are presented based on literature reviews and discussions with HVAC engineers, building operators, facility managers, and commissioning agents. We categorize the maintenance practices into three levels depending on the maintenance effort and coverage: 1) proactive, performance-monitored maintenance; 2) preventive, scheduled maintenance; and 3) reactive, unplanned or no maintenance. A sampled list of maintenance issues, including cooling tower fouling, boiler/chiller fouling, refrigerant over or under charge, temperature sensor offset, outdoor air damper leakage, outdoor air screen blockage, outdoor air damper stuck at fully open position, and dirty filters are investigated in this study using field survey data and detailed simulation models. The energy impacts of both individual maintenance issue and combined scenarios for an office building with central VAV systems and central plant were evaluated by EnergyPlus simulations using three approaches: 1) direct

  8. On detection performance and system configuration of MIMO radar

    Institute of Scientific and Technical Information of China (English)

    TANG Jun; WU Yong; PENG YingNing; WANG XiuTan

    2009-01-01

    Multiple-input multiple-output (MIMO) radar is a new concept with some new characteristics, such as multiple orthogonal waveforms and omnidirectional coverage. Based on Stein's lemma, we use relative entropy as a precise and general measure of error exponent to study detection performance for both MIMO radar and phased array radar. And based on derived analytical results, we further study the system configuration problem of Bistatic MIMO radar systems, where transmitters and receivers are located in different positions. Some interesting results are presented. For phased array radar, when the total numbers of transmitters and receivers are fixed, we should always make the number of transmitters equal to the number of receivers. For MIMO radar, we should use a small number of transmitters in low signal noise ratio (SNR) region, and make the number of transmitters equal to the number of receivers in high SNR region. These results are instructive for deployment of bistatic MIMO radar systems in the future.

  9. A new flight control and management system architecture and configuration

    Science.gov (United States)

    Kong, Fan-e.; Chen, Zongji

    2006-11-01

    The advanced fighter should possess the performance such as super-sound cruising, stealth, agility, STOVL(Short Take-Off Vertical Landing),powerful communication and information processing. For this purpose, it is not enough only to improve the aerodynamic and propulsion system. More importantly, it is necessary to enhance the control system. A complete flight control system provides not only autopilot, auto-throttle and control augmentation, but also the given mission management. F-22 and JSF possess considerably outstanding flight control system on the basis of pave pillar and pave pace avionics architecture. But their control architecture is not enough integrated. The main purpose of this paper is to build a novel fighter control system architecture. The control system constructed on this architecture should be enough integrated, inexpensive, fault-tolerant, high safe, reliable and effective. And it will take charge of both the flight control and mission management. Starting from this purpose, this paper finishes the work as follows: First, based on the human nervous control, a three-leveled hierarchical control architecture is proposed. At the top of the architecture, decision level is in charge of decision-making works. In the middle, organization & coordination level will schedule resources, monitor the states of the fighter and switch the control modes etc. And the bottom is execution level which holds the concrete drive and measurement; then, according to their function and resources all the tasks involving flight control and mission management are sorted to individual level; at last, in order to validate the three-leveled architecture, a physical configuration is also showed. The configuration is distributed and applies some new advancement in information technology industry such line replaced module and cluster technology.

  10. Configuration and technology implications of potential nuclear hydrogen system applications.

    Energy Technology Data Exchange (ETDEWEB)

    Conzelmann, G.; Petri, M.; Forsberg, C.; Yildiz, B.; ORNL

    2005-11-05

    Nuclear technologies have important distinctions and potential advantages for large-scale generation of hydrogen for U.S. energy services. Nuclear hydrogen requires no imported fossil fuels, results in lower greenhouse-gas emissions and other pollutants, lends itself to large-scale production, and is sustainable. The technical uncertainties in nuclear hydrogen processes and the reactor technologies needed to enable these processes, as well waste, proliferation, and economic issues must be successfully addressed before nuclear energy can be a major contributor to the nation's energy future. In order to address technical issues in the time frame needed to provide optimized hydrogen production choices, the Nuclear Hydrogen Initiative (NHI) must examine a wide range of new technologies, make the best use of research funding, and make early decisions on which technology options to pursue. For these reasons, it is important that system integration studies be performed to help guide the decisions made in the NHI. In framing the scope of system integration analyses, there is a hierarchy of questions that should be addressed: What hydrogen markets will exist and what are their characteristics? Which markets are most consistent with nuclear hydrogen? What nuclear power and production process configurations are optimal? What requirements are placed on the nuclear hydrogen system? The intent of the NHI system studies is to gain a better understanding of nuclear power's potential role in a hydrogen economy and what hydrogen production technologies show the most promise. This work couples with system studies sponsored by DOE-EE and other agencies that provide a basis for evaluating and selecting future hydrogen production technologies. This assessment includes identifying commercial hydrogen applications and their requirements, comparing the characteristics of nuclear hydrogen systems to those market requirements, evaluating nuclear hydrogen configuration options

  11. ENERGY STAR Certified Light Commercial HVAC

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 2.0 ENERGY STAR Program Requirements for Light Commercial HVAC that are effective as of...

  12. HVAC design manual for hospitals and clinics

    National Research Council Canada - National Science Library

    2013-01-01

    "Provides in-depth design recommendations and proven, cost effective, and reliable solutions for health care HVAC design that provide low maintenance cost and high reliability based on best practices...

  13. Critical configurations for a system of semidegenerate fermions

    Science.gov (United States)

    Argüelles, Carlos R.; Ruffini, Remo; Fraga, Bernardo M. O.

    2014-09-01

    We study an isothermal system of semidegenerate self-gravitating fermions in general relativity. Such systems present mass density solutions with a central degenerate core, a plateau and a tail, this last following a power law behavior r -2. The different solutions are governed by the free parameters of the model: the degeneracy and the temperature parameters at the center and the particle mass m. We then analyze in detail the free parameter space for a fixed m in the keV region, by studying the one-parameter sequences of equilibrium configurations up to the critical point, which is represented by the maximum in a central density ( ρ 0) vs. core mass ( M c ) diagram. We show that for fully degenerate cores, the known expression for the critical core mass M {/c cr } ∝ m {/pl 3}/ m 2 is obtained, while for low degenerate cores, the critical core mass increases, showing temperature effects in a nonlinear way. The main result of this work is that when applying this theory to model the distribution of dark matter in galaxies from the very center to the outer halos, we do not find any critical corehalo configuration of self-gravitating fermions that would be able to explain the super-massive dark object in their centers and the outer halo simultaneously.

  14. Critical configurations for a system of semi degenerate fermions

    Energy Technology Data Exchange (ETDEWEB)

    Arguelles, Carlos R.; Ruffini, Remo [ICRANet, Piazzale della Repubblica, Pescara (Italy); Sapienza University of Rome, Rome (Italy); Fraga, Bernardo M. [Sapienza University of Rome, Rome (Italy); Universite de Nice Sophia Antipolis, CEDEX (France)

    2014-09-15

    We study an isothermal system of semi degenerate self-gravitating fermions in general relativity. Such systems present mass density solutions with a central degenerate core, a plateau and a tail, this last following a power law behavior r{sup -2}. The different solutions are governed by the free parameters of the model: the degeneracy and the temperature parameters at the center and the particle mass m. We then analyze in detail the free parameter space for a fixed m in the keV region, by studying the one-parameter sequences of equilibrium configurations up to the critical point, which is represented by the maximum in a central density (ρ{sub 0}) vs. core mass (M{sub c}) diagram. We show that for fully degenerate cores, the known expression for the critical core mass M{sup cr}{sub c} {sup a}pprox{sup m3}{sub pl}/m{sup 2} is obtained, while for low degenerate cores, the critical core mass increases, showing temperature effects in a nonlinear way. The main result of this work is that when applying this theory to model the distribution of dark matter in galaxies from the very center to the outer halos, we do not find any critical corehalo configuration of self-gravitating fermions that would be able to explain the super-massive dark object in their centers and the outer halo simultaneously.

  15. Front-End electronics configuration system for CMS

    CERN Document Server

    Gras, P; Funk, W; Gross, L; Vintache, D

    2001-01-01

    The four LHC experiments at CERN have decided to use a commercial SCADA (Supervisory Control And Data Acquisition) product for the supervision of their DCS (Detector Control System). The selected SCADA, which is therefore used for the CMS DCS, is PVSS II from the company ETM. This SCADA has its own database, which is suitable for storing conventional controls data such as voltages, temperatures and pressures. In addition, calibration data and FE (Front-End) electronics configuration need to be stored. The amount of these data is too large to be stored in the SCADA database [1]. Therefore an external database will be used for managing such data. However, this database should be completely integrated into the SCADA framework, it should be accessible from the SCADA and the SCADA features, e.g. alarming, logging should be benefited from. For prototyping, Oracle 8i was selected as the external database manager. The development of the control system for calibration constants and FE electronics configuration has bee...

  16. System and method of providing quick thermal comfort with reduced energy by using directed spot conditioning

    Science.gov (United States)

    Wang, Mingyu; Kadle, Prasad S.; Ghosh, Debashis; Zima, Mark J.; Wolfe, IV, Edward; Craig, Timothy D

    2016-10-04

    A heating, ventilation, and air conditioning (HVAC) system and a method of controlling a HVAC system that is configured to provide a perceived comfortable ambient environment to an occupant seated in a vehicle cabin. The system includes a nozzle configured to direct an air stream from the HVAC system to the location of a thermally sensitive portion of the body of the occupant. The system also includes a controller configured to determine an air stream temperature and an air stream flow rate necessary to establish the desired heat supply rate for the sensitive portion and provide a comfortable thermal environment by thermally isolating the occupant from the ambient vehicle cabin temperature. The system may include a sensor to determine the location of the sensitive portion. The nozzle may include a thermoelectric device to heat or cool the air stream.

  17. ANFIS -Based Navigation for HVAC Service Robot with Image Processing

    Science.gov (United States)

    Salleh, Mohd Zoolfadli Md; Rashid, Nahrul Khair Alang Md; Mohd Mustafah, Yasir

    2013-12-01

    In this paper, we present an ongoing work on the autonomous navigation of a mobile service robot for Heat, Ventilation and Air Condition (HVAC) ducting. CCD camera mounted on the front-end of our robot is used to analyze the ducts openings (blob analysis) in order to differentiate them from other landmarks (blower fan, air outlets and etc). Distance between the robot and duct openings is measured using ultrasonic sensor. Controller chosen is ANFIS where its architecture accepts three inputs; recognition of duct openings, robot positions and distance while the outputs is maneuver direction (left or right).45 membership functions are created from which produces 46 training epochs. In order to demonstrate the functionality of the system, a working prototype is developed and tested inside HVAC ducting in ROBOCON Lab, IIUM.

  18. On-site study of HCFC-22 substitution for HFC non-azeotropic blends (R417A, R422D) on a water chiller of a centralized HVAC system

    Energy Technology Data Exchange (ETDEWEB)

    Torrella, E.; Larumbe, J.A. [Polytechnic University of Valencia, Dep. of Applied Thermodynamics, Camino de Vera 14, E-46022 Valencia (Spain); Cabello, R.; Sanchez, D.; Llopis, R. [Jaume I University, Dep. of Mechanical Engineering and Construction, Campus de Riu Sec s/n, E-12071 Castellon (Spain)

    2010-09-15

    The European Regulation no 2037/2000 has banned manufacturing HCFC refrigerants from January 1st 2010, although its use is allowed up to 2015 if the fluids come from a recycling process. This situation creates the need for developing new working fluids to replace the HCFC in the refrigeration plants now in operation. Among all the HCFCs the R22 is the most widely used in a wide range of applications, especially in air conditioning. This work presents an on-site experimental study of the R22 replacement by two possible substitutes, the HFC-417A and the HFC-422D, in a water chiller in which the energy performance was evaluated. This chiller is part of the centralized HVAC system of a lecture room building at the Jaume I University of Castellon, Spain. This communication compares and analyses main operation parameters of the chiller when operating with each refrigerant in real conditions. (author)

  19. Product Configuration Systems and Consequences for Productivity and Quality

    DEFF Research Database (Denmark)

    Pedersen, Jørgen Lindgaard; Edwards, Kasper

    2004-01-01

    Product Configuration Systems (PCS) are systems to produce quotations to potential buyers of the products an enterprise produces. Typically the products are complex and will first be produced according to specific needs from the customers. From twelve case studies in Danish industry...... with informations about expected and realised costs and benefits in implemented PCS's we have the following results: the three highest aggregated scoring expected benefits are: 1)improved quality in specifications, 2)lower turnaround time, and 3)using less resources.The results achieved are in accordance...... with expectations. A problem is that costs in several cases are unknown or very uncertain. But in cases where they are known there are economic arguments in favour of the PCS....

  20. Ground Systems Development Environment (GSDE) software configuration management

    Science.gov (United States)

    Church, Victor E.; Long, D.; Hartenstein, Ray; Perez-Davila, Alfredo

    1992-01-01

    This report presents a review of the software configuration management (CM) plans developed for the Space Station Training Facility (SSTF) and the Space Station Control Center. The scope of the CM assessed in this report is the Systems Integration and Testing Phase of the Ground Systems development life cycle. This is the period following coding and unit test and preceding delivery to operational use. This report is one of a series from a study of the interfaces among the Ground Systems Development Environment (GSDE), the development systems for the SSTF and the SSCC, and the target systems for SSCC and SSTF. This is the last report in the series. The focus of this report is on the CM plans developed by the contractors for the Mission Systems Contract (MSC) and the Training Systems Contract (TSC). CM requirements are summarized and described in terms of operational software development. The software workflows proposed in the TSC and MSC plans are reviewed in this context, and evaluated against the CM requirements defined in earlier study reports. Recommendations are made to improve the effectiveness of CM while minimizing its impact on the developers.

  1. Comparison of Configurations for High-Recovery Inland Desalination Systems

    Directory of Open Access Journals (Sweden)

    Philip A. Davies

    2012-09-01

    Full Text Available Desalination of brackish groundwater (BW is an effective approach to augment water supply, especially for inland regions that are far from seawater resources. Brackish water reverse osmosis (BWRO desalination is still subject to intensive energy consumption compared to the theoretical minimum energy demand. Here, we review some of the BWRO plants with various system arrangements. We look at how to minimize energy demands, as these contribute considerably to the cost of desalinated water. Different configurations of BWRO system have been compared from the view point of normalized specific energy consumption (SEC. Analysis is made at theoretical limits. The SEC reduction of BWRO can be achieved by (i increasing number of stages, (ii using an energy recovery device (ERD, or (iii operating the BWRO in batch mode or closed circuit mode. Application of more stages not only reduces SEC but also improves water recovery. However, this improvement is less pronounced when the number of stages exceeds four. Alternatively and more favourably, the BWRO system can be operated in Closed Circuit Desalination (CCD mode and gives a comparative SEC to that of the 3-stage system with a recovery ratio of 80%. A further reduction of about 30% in SEC can be achieved through batch-RO operation. Moreover, the costly ERDs and booster pumps are avoided with both CCD and batch-RO, thus furthering the effectiveness of lowering the costs of these innovative approaches.

  2. Using Low-Level Architectural Features for Configuration InfoSec in a General-Purpose Self-Configurable System

    Directory of Open Access Journals (Sweden)

    Nicholas J. Macias

    2009-12-01

    Full Text Available Unique characteristics of biological systems are described, and similarities are made to certain computing architectures. The security challenges posed by these characteristics are discussed. A method of securely isolating portions of a design using introspective capabilities of a fine-grain self-configurable device is presented. Experimental results are discussed, and plans for future work are given.

  3. VARIABLE SPEED INTEGRATED INTELLIGENT HVAC BLOWER

    Energy Technology Data Exchange (ETDEWEB)

    Shixiao Wang; Herman Wiegman; Wilson Wu; John Down; Luana Iorio; Asha Devarajan; Jing Wang; Ralph Carl; Charlie Stephens; Jeannine Jones; Paul Szczesny

    2001-11-14

    This comprehensive topical report discusses the key findings in the development of a intelligent integrated blower for HVAC applications. The benefits of rearward inclined blades over that of traditional forward inclined blades is well documented and a prototype blower design is presented. A comparison of the proposed blower to that of three typical units from the industry is presented. The design of the blower housing is also addressed and the impact of size limitations on static efficiency is discussed. Issues of air flow controllability in the rearward inclined blower is addressed and a solution to this problem is proposed. Several motor design options are discussed including inside-out radial flux designs and novel axial flux designs, all are focused on the various blower needs. The control of the motor-blower and airflow through the use of a high density inverter stage and modern digital signal processor is presented. The key technical challenges of the approach are discussed. The use of the motor as a sensor in the larger heating/ventilating system is also discussed. Diagnostic results for both the motor itself and the blower system are presented.

  4. Software configuration management plan for HANDI 2000 business management system

    Energy Technology Data Exchange (ETDEWEB)

    BENNION, S.I.

    1999-02-10

    The Software Configuration Management Plan (SCMP) describes the configuration management and control environment for HANDI 2000 for the PP and PS software, as well as any custom developed software. This plan establishes requirements and processes for uniform documentation and coordination of HANDI 2000. This SCMP becomes effective as of this document's acceptance and will provide guidance through implementation efforts.

  5. Deep Space Habitat Configurations Based On International Space Station Systems

    Science.gov (United States)

    Smitherman, David; Russell, Tiffany; Baysinger, Mike; Capizzo, Pete; Fabisinski, Leo; Griffin, Brand; Hornsby, Linda; Maples,Dauphne; Miernik, Janie

    2012-01-01

    A Deep Space Habitat (DSH) is the crew habitation module designed for long duration missions. Although humans have lived in space for many years, there has never been a habitat beyond low-Earth-orbit. As part of the Advanced Exploration Systems (AES) Habitation Project, a study was conducted to develop weightless habitat configurations using systems based on International Space Station (ISS) designs. Two mission sizes are described for a 4-crew 60-day mission, and a 4-crew 500-day mission using standard Node, Lab, and Multi-Purpose Logistics Module (MPLM) sized elements, and ISS derived habitation systems. These durations were selected to explore the lower and upper bound for the exploration missions under consideration including a range of excursions within the Earth-Moon vicinity, near earth asteroids, and Mars orbit. Current methods for sizing the mass and volume for habitats are based on mathematical models that assume the construction of a new single volume habitat. In contrast to that approach, this study explored the use of ISS designs based on existing hardware where available and construction of new hardware based on ISS designs where appropriate. Findings included a very robust design that could be reused if the DSH were assembled and based at the ISS and a transportation system were provided for its return after each mission. Mass estimates were found to be higher than mathematical models due primarily to the use of multiple ISS modules instead of one new large module, but the maturity of the designs using flight qualified systems have potential for improved cost, schedule, and risk benefits.

  6. 78 FR 47014 - Configuration Management Plans for Digital Computer Software Used in Safety Systems of Nuclear...

    Science.gov (United States)

    2013-08-02

    ... COMMISSION Configuration Management Plans for Digital Computer Software Used in Safety Systems of Nuclear... 1 of RG 1.169, ``Configuration Management Plans for Digital Computer Software Used in Safety Systems... Accession No. ML12236A132. 2. Revision 1 of RG 1.169, ``Configuration Management Plans for Digital...

  7. Critical configurations for a system of semidegenerate fermions

    CERN Document Server

    Argüelles, Carlos R; Fraga, Bernardo M O

    2014-01-01

    We study an isothermal system of semi-degenerate self-gravitating fermions in general relativity. Such systems present mass density solutions with a central degenerate core, a plateau and a tail which follows a power law behaviour $r^{-2}$. The different solutions are governed by the free parameters of the model: the degeneracy and temperature parameters at the center, and the particle mass $m$. We then analyze in detail the free parameter space for a fixed $m$ in the keV regime, by studying the one-parameter sequences of equilibrium configurations up to the critical point, which is represented by the maximum in a central density ($\\rho_0$) Vs. core mass ($M_c$) diagram. We show that for fully degenerate cores, the known expression for the critical core mass $M_c^{cr}\\propto m_{pl}^3/m^2$ is obtained, while instead for low degenerate cores, the critical core mass increases showing the temperature effects in a non linear way. The main result of this work is that when applying this theory to model the distribut...

  8. Injection molding lens metrology using software configurable optical test system

    Science.gov (United States)

    Zhan, Cheng; Cheng, Dewen; Wang, Shanshan; Wang, Yongtian

    2016-10-01

    Optical plastic lens produced by injection molding machine possesses numerous advantages of light quality, impact resistance, low cost, etc. The measuring methods in the optical shop are mainly interferometry, profile meter. However, these instruments are not only expensive, but also difficult to alignment. The software configurable optical test system (SCOTS) is based on the geometry of the fringe refection and phase measuring deflectometry method (PMD), which can be used to measure large diameter mirror, aspheric and freeform surface rapidly, robustly, and accurately. In addition to the conventional phase shifting method, we propose another data collection method called as dots matrix projection. We also use the Zernike polynomials to correct the camera distortion. This polynomials fitting mapping distortion method has not only simple operation, but also high conversion precision. We simulate this test system to measure the concave surface using CODE V and MATLAB. The simulation results show that the dots matrix projection method has high accuracy and SCOTS has important significance for on-line detection in optical shop.

  9. State of the Art of HVAC Technology in Europe and America

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.; Kazanci, Ongun Berk

    2015-01-01

    mechanisms and media to emit and remove heat or moisture from indoor spaces (e.g. hydronic radiant heating and cooling systems, fan-coil units, and active beams). The main differences between HVAC systems in Europe, North America and other parts of the world are often the indoor terminal units. Type...... for increasing the energy efficiency of HVAC (heating, ventilation and air-conditioning) systems and for increasing the amount of renewable energy used. Especially these types of systems are getting increasing attention in Europe and North-America. In the present study, operation characteristics, possibilities...

  10. Configurable multiplier modules for an adaptive computing system

    Directory of Open Access Journals (Sweden)

    O. A. Pfänder

    2006-01-01

    Full Text Available The importance of reconfigurable hardware is increasing steadily. For example, the primary approach of using adaptive systems based on programmable gate arrays and configurable routing resources has gone mainstream and high-performance programmable logic devices are rivaling traditional application-specific hardwired integrated circuits. Also, the idea of moving from the 2-D domain into a 3-D design which stacks several active layers above each other is gaining momentum in research and industry, to cope with the demand for smaller devices with a higher scale of integration. However, optimized arithmetic blocks in course-grain reconfigurable arrays as well as field-programmable architectures still play an important role. In countless digital systems and signal processing applications, the multiplication is one of the critical challenges, where in many cases a trade-off between area usage and data throughput has to be made. But the a priori choice of word-length and number representation can also be replaced by a dynamic choice at run-time, in order to improve flexibility, area efficiency and the level of parallelism in computation. In this contribution, we look at an adaptive computing system called 3-D-SoftChip to point out what parameters are crucial to implement flexible multiplier blocks into optimized elements for accelerated processing. The 3-D-SoftChip architecture uses a novel approach to 3-dimensional integration based on flip-chip bonding with indium bumps. The modular construction, the introduction of interfaces to realize the exchange of intermediate data, and the reconfigurable sign handling approach will be explained, as well as a beneficial way to handle and distribute the numerous required control signals.

  11. ENVIRONMENTAL AND FINANCIAL INDICATORS OF THE RETROFIT OF HVAC SYSTEM OF A BANK BRANCH = INDICADORES AMBIENTAIS E FINANCEIROS DO RETROFIT DO SISTEMA DE AR CONDICIONADO DE UMA AGÊNCIA BANCÁRIA

    Directory of Open Access Journals (Sweden)

    Marcio Ferreira de Lima

    2016-09-01

    Full Text Available The purpose of this study was to analyze some environmental and financial indicators of the retrofit installation in the heating, ventilating and air conditioning system (HVAC of a bank branch. The building is located in downtown Florianópolis, SC, Brazil. The replacement of the system occurred in 2012. The method analyzed the results of the year 2013 compared with previous years in the matters of: energy efficiency, mitigation of greenhouse gases (GHG and financial investment analysis. The results were: 24.18% electricity savings and 51.31 tCO2eq mitigation of GHG emissions that are equivalent to planting 536 trees. The financial analysis showed that the retrofit is advantageous with benefit-cost ratio 0.60 and 14.85 years payback period. It was concluded that one year after the implementation of the retrofit was achieved the expected objective, which was to replace the old HVAC system with a new one more energy efficient, reducing energy consumption and the resulting reduction of the environmental impact. = O objetivo deste artigo é analisar alguns indicadores ambientais e financeiros da obra de retrofit do sistema de ar condicionado de uma agência bancária. O edifício está localizado no centro da cidade de Florianópolis, SC. A substituição do sistema ocorreu no ano de 2012. O método analisou os resultados do ano de 2013 em comparação com os anos anteriores quanto aos aspectos de: eficiência energética, mitigação de emissões de gases de efeito estufa (GEE e análise financeira do investimento. Os resultados foram: economia de 24,18% de energia elétrica e mitigação de 51,31 tCO2eq das emissões de GEE que são equivalentes ao plantio de 536 árvores. A análise financeira demonstrou que o retrofit é vantajoso com índice benefício/custo de 0,60 e payback de 14,85 anos. Conclui-se que um ano após a execução da obra de retrofit foi atingido o objetivo esperado, que era substituir o sistema de ar condicionado antigo por um

  12. Implementation of new concepts for space HVAC systems in domestic buildings in consideration of cost, consumption and user comfort. Final report; Umsetzung neuer Konzepte der technischen Gebaeudeausruestung im Wohnungsbau unter Beruecksichtigung von Kosten, Verbraeuchen und Nutzerkomfort. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, F.; Sucic, D.; Wendler, M.

    1998-03-01

    The goal of this project was the development of a set of tools for the selection of optimal concepts for HVAC-systems in housing buildings. Several factors are considered. They include technical feasibility, costs for investment, maintenance and operation, energy concumption, environmental impacts and user comfort. It is intended with the help of these tools to identify the most important factors which influence energy consumption and to suggest simple and cost effective measures to reduce energy consumption. Measures include improvements of the envelope, changes in the HVAC-system and its operation according to the needs to the inhabitants of the building. This report describes these components of this tool set which were developed in the frame of the project WohnKomfort. It lists data and rules chosen. In addition we report experiences which we gained with an prototypical implementation. This implementation allows load calculations for more than 60.000 different buildings applying EN 802 (only one zone model) as calculation method. It also supports selection of heating systems for such buildings by offering an evaluation according to user specified criteria including cost, environment and comfort. (orig./MM) [Deutsch] Ziel des Vorhabens war die Entwicklung eines Instrumentariums zur Auswahl optimaler Konzepte fuer technische Anlagen in Wohngebaeuden unter Beruecksichtigung der Faktoren technische Machbarkeit, Erstellungs-, Betriebskosten, Energieverbrauch, Umweltbelastung und Nutzerkomfort. Mit Hilfe dieses Instrumentariums soll es moeglich werden, die Haupteinflussfaktoren fuer den Energieverbrauch anzugeben und Vorschlaege fuer einfache und kostenguenstige Massnahmen zu seiner Reduzierung auf der Seite des Gebaeudes (bauliche Massnahmen) und der Anlage (technische Massnahmen, Nutzerverhalten) anzugeben. In diesem Bericht beschreiben wir die im Vorhaben entwickelten Komponenten des Instrumentariums, die zugrundeliegenden Daten und Regeln sowie Erfahrungen, die

  13. On the usage of knowledge based techniques in configuring computer systems: a case study

    OpenAIRE

    Andersson, Jerker; Andersson, Per

    1989-01-01

    The aim of the thesis has been to define the domains of control structure specification and process station configuration in order to find a general approach applicable to problems concerning the configuration of a process control system or any similar system. These findings are then used as the foundation for constructing a knowledge based system capable of realizing a problem solving method pertaining to the domain of configuring a specific computer system.

  14. Configuration Synthesis and Performance Evaluation Metrics of Lunar Rover Locomotion Systems

    Institute of Scientific and Technical Information of China (English)

    DENG Zongquan; ZHANG Peng; GAO Haibo; HU Ming

    2009-01-01

    A method of topology synthesis based on graph theory and mechanism combination theory was applied to the configuration design of locomotion systems of lunar exploration rovers (LER).Through topology combination of wheel structural unit,suspension unit,and connecting device unit between suspension and load platform,some new locomotion system configurations were proposed and the metrics and indexes to evaluate the performance of the new locomotion system were analyzed.Performance evaluation and comparison between two LER with locomotion systems of different configurations were analyzed.The analysis results indicate that the new locomotion system configuration has good trafficability performance.

  15. Novel multireceiver communication systems configurations based on optimal estimation theory

    Science.gov (United States)

    Kumar, Rajendra

    1992-01-01

    A novel multireceiver configuration for carrier arraying and/or signal arraying is presented. The proposed configuration is obtained by formulating the carrier and/or signal arraying problem as an optimal estimation problem, and it consists of two stages. The first stage optimally estimates various phase processes received at different receivers with coupled phase-locked loops wherein the individual loops acquire and track their respective receivers' phase processes but are aided by each other in an optimal manner via LF error signals. The proposed configuration results in the minimization of the the effective radio loss at the combiner output, and thus maximization of energy per bit to noise power spectral density ratio is achieved. A novel adaptive algorithm for the estimator of the signal model parameters when these are not known a priori is also presented.

  16. Development and maintenance of product configuration systems: Requirements for a documentation tool

    DEFF Research Database (Denmark)

    Hvam, Lars; Christensen, Simon Pape; Jensen, Klaes Ladeby

    2005-01-01

    and structured by using object-oriented system development techniques based on an analysis of the existing product configuration processes of the companies. The analysis was based on the procedure for building configuration systems as developed at CPM, and revealed several common requirements within......Product configuration systems are increasingly applied to automate the configuration of complex products. A configuration system is an expert system designed to combine specified modules according to constraints. The constraints are stored as product data and rules in a product model, and one...... the different companies. Significance: There is an actual need for a documentation tool for product configuration systems. The objective of the study is to identify and capture requirements of such a documentation tool, and serve as a basis for future design and implementation....

  17. HVAC--the importance of clean intake section and dry air filter in cold climate.

    Science.gov (United States)

    Hanssen, S O

    2004-01-01

    HVAC systems, if properly designed, installed, operated and maintained, will improve thermal conditions and air quality indoors. However, the success strongly depends on the design of the system and the quality of the components we use in our HVAC installations. Regrettably, several investigations have revealed that many HVAC installations have a lot of operational and maintenance problems, especially related to moisture, rain and snow entrainment. In short, it seems that too little attention is placed on the design of the intake section, despite the fact that there exists a large number of national and international guidelines and recommendations. This is a serious problem because the air intake is the initial component of the ventilation plant and as such the first line of defense against debris and other outdoor air pollutants. Unfortunately, the design is often an argued compromise between the architect, the civil engineer and the HVAC engineer. In the future, the technical, hygienic and microbiological feature of air intakes must be better ensured in order to avoid the air intake becoming a risk component as regards contamination and indoor air quality. Further, it seems that the magnitude of the problem is not well known, or recognized, by the building designers, engineers and professionals involved in the construction and operation of buildings. This fact needs to be addressed more seriously, because obviously there is a big difference between the idealistic architectonic design, engineering intentions and the real life situation. Several practical recommendations for design and operation of HVAC systems are presented. Following the recommendations will result in less pollution from the HVAC-system and increased indoor environmental quality.

  18. Residential and Light Commercial HVAC. Teacher Edition.

    Science.gov (United States)

    Stephenson, David; Fulkerson, Dan, Ed.

    This curriculum guide contains 18 units of instruction for a competency-based course in residential and light commercial heating, ventilating, and air conditioning (HVAC). Introductory materials include a competency profile and an instructional/task analysis that correlates job training with related information for this course. Each instructional…

  19. Development of a telecommunication line configuration simulation system; Tsushin kaisen kosei simulation system no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Y. [Chubu Electric Power Co., Inc., Nagoya (Japan)

    1997-06-01

    A prototype of line configuration simulation system has been developed, by which route search and check of various conditions of telecommunication line configuration can be conducted using a computer. For the setting and change of telecommunication line, the route search from start terminal to end terminal of the line, search of vacant channels of the pass, and check of various conditions, such as constraint of non-mixing of A/B systems for ensuring the line reliability, transmission delay time and two-route configuration, are currently necessary. With the expansion of telecommunication network, the line configuration works have become further complicated. The developed prototype was verified. For the operation performance, input works of indicating data can be reduced, resulting in the easy input. For the responsibility, processing time was measured for various search patterns. The processing speed in the practical level could be realized by employing various high-speed methods. It takes 80 minutes per line for processing the current line configuration by manual management. It took only 10 minutes for processing using this system. Thus, the effectiveness of this system was confirmed. 13 figs., 5 tabs.

  20. Dynamic airspace configuration algorithms for next generation air transportation system

    Science.gov (United States)

    Wei, Jian

    The National Airspace System (NAS) is under great pressure to safely and efficiently handle the record-high air traffic volume nowadays, and will face even greater challenge to keep pace with the steady increase of future air travel demand, since the air travel demand is projected to increase to two to three times the current level by 2025. The inefficiency of traffic flow management initiatives causes severe airspace congestion and frequent flight delays, which cost billions of economic losses every year. To address the increasingly severe airspace congestion and delays, the Next Generation Air Transportation System (NextGen) is proposed to transform the current static and rigid radar based system to a dynamic and flexible satellite based system. New operational concepts such as Dynamic Airspace Configuration (DAC) have been under development to allow more flexibility required to mitigate the demand-capacity imbalances in order to increase the throughput of the entire NAS. In this dissertation, we address the DAC problem in the en route and terminal airspace under the framework of NextGen. We develop a series of algorithms to facilitate the implementation of innovative concepts relevant with DAC in both the en route and terminal airspace. We also develop a performance evaluation framework for comprehensive benefit analyses on different aspects of future sector design algorithms. First, we complete a graph based sectorization algorithm for DAC in the en route airspace, which models the underlying air route network with a weighted graph, converts the sectorization problem into the graph partition problem, partitions the weighted graph with an iterative spectral bipartition method, and constructs the sectors from the partitioned graph. The algorithm uses a graph model to accurately capture the complex traffic patterns of the real flights, and generates sectors with high efficiency while evenly distributing the workload among the generated sectors. We further improve

  1. HVAC optimization as facility requirements change with corporate restructuring

    Energy Technology Data Exchange (ETDEWEB)

    Rodak, R.R.; Sankey, M.S.

    1997-06-01

    The hyper-competitive, dynamic 1990`s forced many corporations to {open_quotes}Right-Size,{close_quotes} relocating resources and equipment -- even consolidating. These changes led to utility reduction if HVAC optimization was thoroughly addressed, and energy conservation opportunities were identified and properly designed. This is true particularly when the facility`s heating and cooling systems are matched to correspond with the load changes attributed to the reduction of staff and computers. Computers have been downsized and processing power per unit of energy input increased, thus, the need for large mainframe computer centers, and their associated high intensity energy usage, have been decreased or eliminated. Cooling, therefore, also has been reduced.

  2. HVAC in sustainable office buildings a bridge between owners and engineers

    CERN Document Server

    Hovorka, Frank; Kurnitski, Jarek; Litiu, Andrei

    2012-01-01

    This guidebook aims to build a bridge between the real estate community and the engineering community. It explains the challenges of property valuation based on real data and how the sustainability and HVAC-technology can have an impact on value. It also gathers the latest HVAC- and other technologies used in sustainable buildings and gives some real case study examples. But maybe the most important part in terms of improved communication between the owners and engineers is the list of questions to be asked during the life time of a building. It is impossible to give all the right answers in this guidebook, but we will raise some pertinent questions. As climates and cultures are different, as well as existing building types and energy production, the same solutions do not solve problems universally. This guidebook is aimed for the owners and architects as well as engineers. It doesn’t require deep technical knowhow of HVAC-systems or real estate valuation.

  3. Energy Renovations: Volume 14: HVAC - A Guide for Contractors to Share with Homeowners

    Energy Technology Data Exchange (ETDEWEB)

    Gilbride, Theresa L.; Baechler, Michael C.; Hefty, Marye G.; Hand, James R.; Love, Pat M.

    2011-08-29

    This report was prepared by PNNL for DOE's Building America program and is intended as a guide that energy performance contractors can share with homeowners to describe various energy-efficient options for heating, cooling, and ventilating existing homes. The report provides descriptions of many common and not-so-common HVAC systems, including their advantages and disadvantages, efficiency ranges and characteristics of high-performance models, typical costs, and climate considerations. The report also provides decision trees and tables of useful information for homeowners who are making decisions about adding, replacing, or upgrading existing HVAC equipment in their homes. Information regarding home energy performance assessments (audits) and combustion safety issues when replacing HVAC equipment are also provided.

  4. Energy Savings Potential and RD&D Opportunities for Non-Vapor-Compression HVAC Technologies

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2014-03-01

    While vapor-compression technologies have served heating, ventilation, and air-conditioning (HVAC) needs very effectively, and have been the dominant HVAC technology for close to 100 years, the conventional refrigerants used in vapor-compression equipment contribute to global climate change when released to the atmosphere. This Building Technologies Office report: --Identifies alternatives to vapor-compression technology in residential and commercial HVAC applications --Characterizes these technologies based on their technical energy savings potential, development status, non-energy benefits, and other factors affecting end-user acceptance and their ability to compete with conventional vapor-compression systems --Makes specific research, development, and deployment (RD&D) recommendations to support further development of these technologies, should DOE choose to support non-vapor-compression technology further.

  5. 77 FR 50727 - Configuration Management Plans for Digital Computer Software Used in Safety Systems of Nuclear...

    Science.gov (United States)

    2012-08-22

    ... software configuration management (SCM) as described in the Institute of Electrical and Electronics..., systems, and components important to safety throughout the life of the unit. This draft regulatory...

  6. Enhanced configuration of a water detritiation system; impact on ITER Isotope Separation System based cryogenic distillation

    Energy Technology Data Exchange (ETDEWEB)

    Cristescu, Ion, E-mail: ion.cristescu@kit.edu

    2016-11-01

    Highlights: • An enhanced configuration of ITER WDS has been developed. • The proposed configuration allows minimization of hazards due to the reduction of tritium inventory. • The load on the tritium recovery system (ITER ISS) is minimized with benefits on mitigation of the explosion hazards. - Abstract: Tritiated water is generated in the ITER systems by various sources and may contain deuterium and tritium at various concentrations. The reference process for the ITER Water Detritiation System is based on Combined Electrolysis Catalytic Exchange (CECE) configuration. During long time operation of the CECE process, the accumulation of deuterium in the electrolysis unit and consequently along the Liquid Phase Catalytic Exchange (LPCE) column is unavoidable with consequences on the overall detritiation factor of the system. Beside the deuterium issue in the process, the large amount of the tritiated water with tritium activity up to 500 Ci/kg in the electrolysis cells is a concern from the safety aspect of the plant. The enhanced configuration of a system for processing tritiated water allows mitigation of the effects due to deuterium accumulation and also reduction of tritium inventory within the electrolysis system. In addition the benefits concerning to the interface between the water detritiation system and tritium recovery based cryogenic distillation are also presented.

  7. DISAIN SISTEM KENDALI MESIN AIR LEAK TEST MENGGUNAKAN SISTEM KENDALI PLC OMRON CJ2M DI HVAC (HEATING, VENTILATING, AND AIR CONDITIONING LINE 6

    Directory of Open Access Journals (Sweden)

    Syahril Ardi

    2015-03-01

    Full Text Available Pada proses produksi pembuatan komponen HVAC (Heating, Ventilating, and Air Conditioning dari perusahaan manufaktur di Indonesia, memerlukan proses pengecekan kebocoran pada bagian HVAC. Proses pengecekan ini dilakukan untuk memastikan tidak ada komponen HVAC yang bocor sebelum dikirim ke pihak pelanggan. Penelitian ini dilakukan untuk membuat system dan alat air leak test. Mesin air leak test ini menggunakan prinsip kerja differential pressure air leak test, yaitu metode yang membandingkan antara tekanan udara yang diberikan ke produk dan master produk. Pada penelitian ini, kami membuat disain mesin air leak test menggunakan sistem kendali berupa air leak tester, PLC, dan HMI. Berdasarkan kondisi dengan kapasitas produksi yang meningkat karena bertambahnya permintaan dari customer, dapat ditanggulangi dengan adanya share loading produksi dari HVAC line 4 ke line baru, yaitu HVAC line 6. Hasil yang didapat dari pengujian deteksi kebocoran produk,didapat nilai parameter kebocoran produk sebesar 2.23 ml/min.

  8. Fully nonlinear internal waves in a system of two fluids. 1: Shallow water configuration; 2: Deep water configuration

    Energy Technology Data Exchange (ETDEWEB)

    Choi, W.; Camassa, R.

    1998-12-31

    The authors derive model equations that govern the evolution of internal gravity waves at the interface of two immiscible fluids. These models follow from the original Euler equations under the sole assumption that the waves are long compared to the undisturbed thickness of one of the fluid layers. No smallness assumption on the wave amplitude is made. Here the shallow water configuration is first considered, whereby the waves are taken to be long with respect to the total undisturbed thickness of the fluids. In part 2, the authors derive models for the configuration in which one of the two fluids has a thickness much larger than the wavelength. The fully nonlinear models contain the Korteweg-de Vries (KdV) equation and the intermediate-long-wave (ILW) equation, for shallow and deep water configurations respectively, as special cases in the limit of weak nonlinearity and unidirectional wave propagation. In particular, for a solitary wave of given amplitude, the characteristic wavelength is larger and the wave speed smaller than their counterparts for solitary wave solutions of the weakly nonlinear equations. These features are compared and found in overall good agreement with available experimental data for solitary waves of large amplitude in two-fluid systems.

  9. Testing of blowers and HVAC systems. Guide for energy optimization regarding ambient air ventilation systems. Pruefungen von Ventilatoren und Raumlufttechnischen Geraeten. Wegweiser zur Energieoptimierung bei RLT-Geraeten

    Energy Technology Data Exchange (ETDEWEB)

    Breit, O.

    1992-09-01

    Through a continuously increasing environmental consciousness and the increase of energy cost to be expected in the next years, ambient air ventilation systems with an optimized energy consumption are increasingly applied. For the determination of the energy consumption, special test rigs for the capacity are necessary. They consist of two climatic chambers arranged side by side, two measured sections and two speed controlled supporting fans. The tests carried out on the capacity and function of ambient air ventilation systems showed that the power consumption and thus, the energy consumption can be considerably reduced through constructional changes and an exact design of single components based on measured results. (BWI).

  10. Database Foundation For The Configuration Management Of The CERN Accelerator Controls Systems

    CERN Document Server

    Zaharieva, Z; Peryt, M

    2011-01-01

    The Controls Configuration Database (CCDB) and its interfaces have been developed over the last 25 years in order to become nowadays the basis for the Configuration Management of the Controls System for all accelerators at CERN. The CCDB contains data for all configuration items and their relationships, required for the correct functioning of the Controls System. The configuration items are quite heterogeneous, depicting different areas of the Controls System – ranging from 3000 Front-End Computers, 75 000 software devices allowing remote control of the accelerators, to valid states of the Accelerators Timing System. The article will describe the different areas of the CCDB, their interdependencies and the challenges to establish the data model for such a diverse configuration management database, serving a multitude of clients. The CCDB tracks the life of the configuration items by allowing their clear identification, triggering of change management processes as well as providing status accounting and aud...

  11. Introduction to Heating, Ventilation and Air Conditioning (HVAC). Introduction to Construction Series. Instructor Edition.

    Science.gov (United States)

    Associated General Contractors of America, Washington, DC.

    This module on introductory heating, ventilating, and air conditioning (HVAC) is one of a series of modules designed to teach basic skills necessary for entry-level employment in this field. The module contains four instructional units that cover the following topics: (1) HVAC materials; (2) HVAC tools; (3) HVAC layout; and (4) HVAC basic skills.…

  12. Introduction to Heating, Ventilation and Air Conditioning (HVAC). Introduction to Construction Series. Instructor Edition.

    Science.gov (United States)

    Associated General Contractors of America, Washington, DC.

    This module on introductory heating, ventilating, and air conditioning (HVAC) is one of a series of modules designed to teach basic skills necessary for entry-level employment in this field. The module contains four instructional units that cover the following topics: (1) HVAC materials; (2) HVAC tools; (3) HVAC layout; and (4) HVAC basic skills.…

  13. Supply strategy configuration in fragmented production systems: An empirical study

    Directory of Open Access Journals (Sweden)

    Claudia Chackelson

    2013-07-01

    Full Text Available Purpose: Companies survive in saturated markets trying to be more productive and more efficient. In this context, it becomes critical for companies to manage the entire supply network to optimize overall performance.  Hence, the supply strategy plays an important role because it influences the way in which production and logistics network has to be configured and managed. This paper explores the benefits obtained configuring different supply strategies adapted to customer needs.Design/methodology/approach: For this purpose a case research from a Tier 2 point of view of the supply chain has been conducted. Findings and Originality/value: The case research demonstrates that a higher service level, less holding costs and increase turnovers can be obtained implementing the adequate supply strategy. Originality/value: There is a scarcity of research specifically focused on applied Supply Chain Principles within network configuration processes. Moreover, there are few empirical studies of global Tier 2 with multiple decoupling points into its supply chain network.

  14. Optimal Configuration of Virtual Links for Avionics Network Systems

    Directory of Open Access Journals (Sweden)

    Dongha An

    2015-01-01

    Full Text Available As the bandwidth and scalability constraints become important design concerns in airborne networks, a new technology, called Avionics Full Duplex Switched Ethernet (AFDX, has been introduced and standardized as a part 7 in ARNIC 664. However, since previous research interests for AFDX are mainly bounded for analyzing the response time where flows information is given, configuration problem for both Maximum Transmission Unit (MTU and Bandwidth Allocation Gap (BAG over virtual links in AFDX networks has not been addressed yet even though it has great impact on required bandwidth. Thus, in this paper, we present two configuration approaches to set MTU and BAG values on virtual links efficiently while meeting the requirement of AFDX. The first is to search available feasible configuration (MTU, BAG pairs to satisfy application requirements as well as AFDX switch constraints, and the second is to get an optimal pair to minimize required bandwidth through well-known branch-and-bound algorithm. We analyze the complexity of the proposed algorithm and then evaluate the proposed algorithm by simulation. Finally, we prove that the proposed schemes are superior to general approach in the aspects of speed and required bandwidth in AFDX networks.

  15. Software Configuration Management Plan for the B-Plant Canyon Ventilation Control System

    Energy Technology Data Exchange (ETDEWEB)

    MCDANIEL, K.S.

    1999-08-31

    Project W-059 installed a new B Plant Canyon Ventilation System. Monitoring and control of the system is implemented by the Canyon Ventilation Control System (CVCS). This Software Configuration Management Plan provides instructions for change control of the CVCS.

  16. 75 FR 69469 - Health Net, Inc., Claims Processing Group and Systems Configuration Organization, Including On...

    Science.gov (United States)

    2010-11-12

    ..., 2010 (75 FR 34174). At the request of the State agency, the Department reviewed the certification for... Employment and Training Administration Health Net, Inc., Claims Processing Group and Systems Configuration..., applicable to workers of Health Net, Inc., Claims Processing Group and Systems Configuration...

  17. Alignment of Configuration and Documentation for Highly Engineered Complex Product Configuration Systems: a Demonstration from a Case Study

    DEFF Research Database (Denmark)

    Shafiee, Sara; Kristjansdottir, Katrin; Hvam, Lars

    2015-01-01

    Adequate documentation is critical for successful implementation, maintenance and further developments of product configuration system (PCS) specially in companies making complex and highly engineered products. This article is based on experience of modelling and utilizing a PCS from an Engineer......-To-Order (ETO), where the main focus is on the challenges concerned with the documentation of the PCS, both in the development and production phase. Aligning the development of the PCS with an automatic documentation system creates value. Using the suggested method for documentation facilitates the following...... activities: (1) iterative testing of the system during the development, (2) communication with domain experts, (3) documentation and maintenance, and finally (4) updates without spending a lot of time and resources. This article is supplemented with a case study from an ETO company where the method...

  18. Alignment of Configuration and Documentation for Highly Engineered Complex Product Configuration Systems: a Demonstration from a Case Study

    DEFF Research Database (Denmark)

    Shafiee, Sara; Kristjansdottir, Katrin; Hvam, Lars

    2015-01-01

    Adequate documentation is critical for successful implementation, maintenance and further developments of product configuration system (PCS) specially in companies making complex and highly engineered products. This article is based on experience of modelling and utilizing a PCS from an Engineer......-To-Order (ETO), where the main focus is on the challenges concerned with the documentation of the PCS, both in the development and production phase. Aligning the development of the PCS with an automatic documentation system creates value. Using the suggested method for documentation facilitates the following...... activities: (1) iterative testing of the system during the development, (2) communication with domain experts, (3) documentation and maintenance, and finally (4) updates without spending a lot of time and resources. This article is supplemented with a case study from an ETO company where the method...

  19. Wireless sensors in heterogeneous networked systems configuration and operation middleware

    CERN Document Server

    Cecilio, José

    2014-01-01

    This book presents an examination of the middleware that can be used to configure and operate heterogeneous node platforms and sensor networks. The middleware requirements for a range of application scenarios are compared and analysed. The text then defines middleware architecture that has been integrated in an approach demonstrated live in a refinery. Features: presents a thorough introduction to the major concepts behind wireless sensor networks (WSNs); reviews the various application scenarios and existing middleware solutions for WSNs; discusses the middleware mechanisms necessary for hete

  20. Expected and Realized Costs and Benefits from Implementing Product Configuration Systems

    DEFF Research Database (Denmark)

    Edwards, Kasper

    2010-01-01

    Product configuration systems (PCS) are a technology well suited for mass customization and support the task of configuring the product to the individual customer’s needs. PCS are at the same time complex software systems that may be tailored to solve a variety of problems for a firm, e.g. suppor......Product configuration systems (PCS) are a technology well suited for mass customization and support the task of configuring the product to the individual customer’s needs. PCS are at the same time complex software systems that may be tailored to solve a variety of problems for a firm, e.......g. supporting the quotation process or validating the structure of a product. This paper reports findings from a study of 12 Danish firms, which at the time of the study have implemented or are in the process of implementing product configuration systems. 12 costs and 12 benefits are identified in literature...

  1. A multi-perspective approach for the design of product configuration systems

    DEFF Research Database (Denmark)

    Hvam, Lars; Mortensen, Niels Henrik

    2007-01-01

    This article presents a procedure for building a product configuration system. The procedure includes, at the first phase, an analysis and redesign of the business processes, which are to be supported with product configuration systems. The next phase includes an analysis of the product assortmen......, and the set up of a so-called product variant master. Finally, the product configuration system is designed and implemented using object-oriented modeling. The procedure has been tested at a Danish company making electronic switchboards with positive results.......This article presents a procedure for building a product configuration system. The procedure includes, at the first phase, an analysis and redesign of the business processes, which are to be supported with product configuration systems. The next phase includes an analysis of the product assortment...

  2. IFC HVAC interface to EnergyPlus - A case of expanded interoperability for energy simulation

    Energy Technology Data Exchange (ETDEWEB)

    Bazjanac, Vladimir; Maile, Tobias

    2004-03-29

    Tedious manual input of data that define a building, its systems and its expected pattern of use and operating schedules for building energy performance simulation has in the past diverted time and resources from productive simulation runs. In addition to its previously released IFCtoIDF utility that semiautomates the import of building geometry, the new IFC HVAC interface to EnergyPlus (released at the end of 2003) makes it possible to import and export most of the data that define HVAC equipment and systems in a building directly from and to other IFC compatible software tools. This reduces the manual input of other data needed for successful simulation with EnergyPlus to a minimum. The main purpose of this new interface is to enable import of HVAC equipment and systems definitions, generated by other IFC compatible software tools (such as HVAC systems design tools) and data bases, into EnergyPlus, and to write such definitions contained in EnergyPlus input files to the original IFC files from which building geometry was extracted for the particular EnergyPlus input. In addition, this interface sets an example for developers of other software tools how to import and/or export data other than building geometry from and/or into EnergyPlus. This paper describes the necessary simplifications and shortcuts incorporated in this interface, its operating environment, interface architecture, and the basic conditions and methodology for its use with EnergyPlus.

  3. Estimating the HVAC energy consumption of plug-in electric vehicles

    Science.gov (United States)

    Kambly, Kiran R.; Bradley, Thomas H.

    2014-08-01

    Plug in electric vehicles are vehicles that use energy from the electric grid to provide tractive and accessory power to the vehicle. Due to the limited specific energy of energy storage systems, the energy requirements of heating, ventilation, and air conditioning (HVAC) systems for cabin conditioning can significantly reduce their range between charges. Factors such as local ambient temperature, local solar radiation, local humidity, length of the trip and thermal soak have been identified as primary drivers of cabin conditioning loads and therefore of vehicle range. The objective of this paper is to develop a detailed systems-level approach to connect HVAC technologies and usage conditions to consumer-centric metrics of vehicle performance including energy consumption and range. This includes consideration of stochastic and transient inputs to the HVAC energy consumption model including local weather, solar loads, driving behavior, charging behavior, and regional passenger fleet population. The resulting engineering toolset is used to determine the summation of and geographical distribution of energy consumption by HVAC systems in electric vehicles, and to identify regions of US where the distributions of electric vehicle range are particularly sensitive to climate.

  4. A documentation tool for product configuration systems - improving the documentation task

    DEFF Research Database (Denmark)

    Hvam, Lars; Jensen, Klaes Ladeby

    2005-01-01

    of a documentation tool for product configuration, based on CPM's procedure and experience from four Danish industrial companies which have applied the procedure. The requirements have been gathered and structured by using object-oriented system development techniques based on an analysis of the existing prod......Configuration systems are increasingly applied to automate the configuration of complex products. A configuration system is an expert system designed to combine specified modules according to constraints. The constraints are stored as product data and rules in a product model, and one of the most......-uct configuration processes of the companies. The analysis was based on the procedure for building product models as de-veloped at CPM, and revealed several common requirements within the different companies....

  5. Thermoelectric System in Different Thermal and Electrical Configurations: Its Impact in the Figure of Merit

    Directory of Open Access Journals (Sweden)

    Alexander Vargas-Almeida

    2013-05-01

    Full Text Available In this work, we analyze different configurations of a thermoelectric system (TES composed of three thermoelectric generators (TEGs. We present the following considerations: (a TES thermally and electrically connected in series (SC; (b TES thermally and electrically connected in parallel (PSC; and (c parallel thermally and series electrical connection (SSC. We assume that the parameters of the TEGs are temperature-independent. The systems are characterized by three parameters, as it has been showed in recent investigations, namely, its internal electrical resistance, R, thermal conductance under open electrical circuit condition, K, and Seebeck coefficient α. We derive the equivalent parameters for each of the configurations considered here and calculate the Figure of Merit Z for the equivalent system. We show the impact of the configuration of the system on Z, and we suggest optimum configuration. In order to justify the effectiveness of the equivalent Figure of Merit, the corresponding efficiency has been calculated for each configuration.

  6. The state of HVAC in Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, M.M. [Air Quality Systems, Shawnee Mission, KS (United States)

    1997-07-01

    With the chartering of the Manual de Anda ASHRAE Chapter in Mexico City, the first chapter in Latin America, and with increasing cross-border trade and investment as a result of NAFTA, it`s important for US and Canadian engineers to understand the state of HVAC technology in Mexico. The goal of this article is to introduce the reader to some industry leaders in Mexico and to show their creative design and installation expertise by reviewing some recent projects.

  7. Electrostatic MEMS vibration energy harvester for HVAC applications

    Science.gov (United States)

    Oxaal, J.; Hella, M.; Borca-Tasciuc, D.-A.

    2015-12-01

    This paper reports on an electrostatic MEMS vibration energy harvester with gapclosing interdigitated electrodes, designed for and tested on HVAC air ducts. The device is fabricated on SOI wafers using a custom microfabrication process. A dual-level physical stopper system is implemented in order to control the minimum gap between the electrodes and maximize the power output. It utilizes cantilever beams to absorb a portion of the impact energy as the electrodes approach the impact point, and a film of parylene with nanometer thickness deposited on the electrode sidewalls, which defines the absolute minimum gap and provides electrical insulation. The fabricated device was first tested on a vibration shaker to characterize its resonant behavior. The device exhibits spring hardening behavior due to impacts with the stoppers and spring softening behavior with increasing voltage bias. Testing was carried out on HVAC air duct vibrating with an RMS acceleration of 155 mgRMS and a primary frequency of 60 Hz with a PSD of 7.15·10-2 g2/Hz. The peak power measured is 12nW (0.6 nW RMS) with a PSD of 6.9·10-11 W/Hz at 240 Hz (four times of the primary frequency of 60 Hz), which is the highest output reported for similar vibration conditions and biasing voltages.

  8. Using a Configuration System to Design Toilets and Place Installation Shafts

    DEFF Research Database (Denmark)

    Kudsk, Anders; Hvam, Lars; Thuesen, Christian Langhoff

    2013-01-01

    The aim of this research is to discover how configuration systems can support a product's design process when a high degree of variation is required and a very open or endless space exists for possible configurations. The article is based on an industrial case involving a firm that wishes to offer...... a bathroom configurator to architects. The aim of the configurator is to help architects design a bathroom according to relevent requirements and norms. In offering the configurator, the firm aims to enable a design that can be coordinated with a prefabricated installation shaft sold by the firm, and also...... to create customer leads. Four scenarios are developed for how design can be supported by four different types of configuration technologies. The four scenarios are evaluated in relation to a number of functional and technical requirements. The scenarios indicate that a good and varied range...

  9. AUTOMATING THE CONFIGURATION OF THE CONTROLS SYSTEMS OF THE LHC EXPERIMENTS

    CERN Multimedia

    Calheiros, F; Varela, F

    2007-01-01

    The supervisory layer of the Large Hadron Collider (LHC) experiments is based on the Prozeßvisualisierungs- und Steuerungsystem (PVSS) [1] and the Joint COntrols Project (JCOP) Framework (FW) [2]. This controls framework includes a Finite State Machine (FSM) toolkit, which allows to operate the control systems according to a well-defined set of states and commands. During the FSM transitions of the detectors, it is required to re-configure parts of the control systems. All configuration parameters of the devices integrated into the control system are stored in the so-called configuration database. In this paper the JCOP FW FSM-Configuration database tool is presented. This tool ensures the availability of all required configuration data, for a given type of run of the experiment, in the PVSS sub-detector control applications. The chosen implementation strategy is discussed in the paper. The approach enables the standalone operation of different partitions of the detectors simultaneously while ensuring indepe...

  10. HVAC Equipment Design Options for Near-Zero-Energy Homes (NZEH) -A Stage 2 Scoping Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Van D [ORNL

    2005-11-01

    Although the energy efficiency of heating, ventilating, and air-conditioning (HVAC) equipment has increased substantially in recent years, new approaches are needed to continue this trend. Conventional unitary equipment and system designs have matured to a point where cost-effective, dramatic efficiency improvements that meet near-zero-energy housing (NZEH) goals require a radical rethinking of opportunities to improve system performance. The large reductions in HVAC energy consumption necessary to support the NZEH goals require a systems-oriented analysis approach that characterizes each element of energy consumption, identifies alternatives, and determines the most cost-effective combination of options. In particular, HVAC equipment must be developed that addresses the range of special needs of NZEH applications in the areas of reduced HVAC and water heating energy use, humidity control, ventilation, uniform comfort, and ease of zoning. This report describes results of a scoping assessment of HVAC system options for NZEH homes. ORNL has completed a preliminary adaptation, for consideration by The U.S. Department of Energy, Energy Efficiency and Renewable Energy Office, Building Technologies (BT) Program, of Cooper's (2001) stage and gate planning process to the HVAC and Water Heating element of BT's multi-year plan, as illustrated in Figure 1. In order to adapt to R&D the Cooper process, which is focused on product development, and to keep the technology development process consistent with an appropriate role for the federal government, the number and content of the stages and gates needed to be modified. The potential federal role in technology development involves 6 stages and 7 gates, but depending on the nature and status of the concept, some or all of the responsibilities can flow to the private sector for product development beginning as early as Gate 3. In the proposed new technology development stage and gate sequence, the Stage 2 &apos

  11. Evaluating performance indices of a shopping centre and implementing HVAC control principles to minimize energy usage

    Energy Technology Data Exchange (ETDEWEB)

    Canbay, C.S. [Energy Engineering Programme, Izmir Institute of Technology, Izmir (Turkey); Hepbasli, A. [Faculty of Engineering, Mechanical Engineering Department, Ege University, Izmir (Turkey); Gokcen, G. [Faculty of Engineering, Mechanical Engineering Department, Izmir Institute of Technology, Izmir (Turkey)

    2004-07-01

    Heating, ventilation and air-conditioning (HVAC) systems in buildings must be integrated with an efficient control scheme to maintain comfort under any load conditions. Efficient HVAC control is often the most cost-effective option to improve the energy efficiency of a building. However, HVAC processes are non-linear, and characteristics change on a seasonal basis, so the effect of changing the control strategy is usually difficult to predict. The present study aims to reduce energy consumption by defining new HVAC control strategies and tuning control loops in a shopping centre. First, an energy audit was performed to investigate the potential for energy savings and to redefine the control scenarios, while a methodology for the shopping centre was developed. Performance indices were then calculated and compared with the yardsticks. Next, normalised performance indices were computed to reach out a better understanding of the building's efficiency. Finally, new strategies were implemented with the help of the existing building management system (BMS) and about 22% of energy saving was achieved. (author)

  12. Systems design analysis applied to launch vehicle configuration

    Science.gov (United States)

    Ryan, R.; Verderaime, V.

    1993-01-01

    As emphasis shifts from optimum-performance aerospace systems to least lift-cycle costs, systems designs must seek, adapt, and innovate cost improvement techniques in design through operations. The systems design process of concept, definition, and design was assessed for the types and flow of total quality management techniques that may be applicable in a launch vehicle systems design analysis. Techniques discussed are task ordering, quality leverage, concurrent engineering, Pareto's principle, robustness, quality function deployment, criteria, and others. These cost oriented techniques are as applicable to aerospace systems design analysis as to any large commercial system.

  13. A Novel Method for Saving Energy of HVAC Using Autonomous Variable Air Velocity Based On Thermal Comfort

    Science.gov (United States)

    Auttawaitkul, Yingrak; Therdyothin, Apichit; Monyakul, Veerapol

    The tower building categories used in the energy breakdown are Electric lighting, the heating, ventilating, and air conditioning (HVAC) auxiliary and Office equipment. The HVAC system has the greatest energy saving potential as it is the major energy consumer. It consumes approximately 64 percent of the total building energy. A good HVAC in buildings helps reduce energy use and maintain occupant comfort. To this end, there are many systems and equipment conditions to observe HVAC systems. This paper critically examines indoor climate control technologies to reduce the HVAC system energy. The autonomous variable air volume diffusers are interconnected to simulate the responses of the system. The constrained optimal control problem is formulated and solved for increased operative temperature. The experiment results show that by increasing the operative temperature from 25°C to 27°C, the electrical energy can be saved by 11.64 percent. The proposed method feeds back the output air to input boundary conditions of the same human thermal sensation even though the air velocity distributions in the sections are different from each other. The experiment results also show that the proposed method can maintain the PMV values in an interval of -0.5 to +0.5 at an acceptable air velocity range.

  14. A multi-perspective approach for the design of product configuration systems

    DEFF Research Database (Denmark)

    Hvam, Lars; Mortensen, Niels Henrik

    2007-01-01

    This article presents a procedure for building a product configuration system. The procedure includes, at the first phase, an analysis and redesign of the business processes, which are to be supported with product configuration systems. The next phase includes an analysis of the product assortment......, and the set up of a so-called product variant master. Finally, the product configuration system is designed and implemented using object-oriented modeling. The procedure has been tested at a Danish company making electronic switchboards with positive results....

  15. Accounting for User Diversity in Configuring Online Systems.

    Science.gov (United States)

    Woolliams, Peter; Gee, David

    1992-01-01

    Discusses cultural diversity in human-computer interactions and in the design of online systems. Topics addressed include cognitive psychology; North American and European ethnocentricity; online systems and their organizational setting; models for organization culture; corporate culture; international systems and country-specific cultures; and…

  16. An agile documentation system for highly engineered, complex product configuration systems

    DEFF Research Database (Denmark)

    Shafiee, Sara; Hvam, Lars; Kristjansdottir, Katrin

    2015-01-01

    When modelling and maintaining a product configuration system (PCS) there is a need for a complete and updated documentation of the system. This research work focuses on a framework for documenting PCSs based on structures, data and constraints already implemented in the PCS. Looking at previously...... suggested PCS documentation, systems focus on creating the documentation separated from PCS. Documenting the PCS separately request extra time and resources. We suggest building the PCS models and then extracting the structure, data and constraints for documentation from PCS. This makes the task...... of documentation easier and less time consuming....

  17. The Network Configuration of an Object Relational Database Management System

    Science.gov (United States)

    Diaz, Philip; Harris, W. C.

    2000-01-01

    The networking and implementation of the Oracle Database Management System (ODBMS) requires developers to have knowledge of the UNIX operating system as well as all the features of the Oracle Server. The server is an object relational database management system (DBMS). By using distributed processing, processes are split up between the database server and client application programs. The DBMS handles all the responsibilities of the server. The workstations running the database application concentrate on the interpretation and display of data.

  18. Optimal configuration of an integrated power and transport system

    DEFF Research Database (Denmark)

    Juul, Nina; Meibom, Peter

    2011-01-01

    optimal investments in both power plants and vehicle technologies is presented in this article. The model includes the interactions between the power system and the transport system including the competition between flexibility measures such as hydrogen storage in combination with electrolysis, heat...

  19. Configuration of electro-optic fire source detection system

    Science.gov (United States)

    Fabian, Ram Z.; Steiner, Zeev; Hofman, Nir

    2007-04-01

    The recent fighting activities in various parts of the world have highlighted the need for accurate fire source detection on one hand and fast "sensor to shooter cycle" capabilities on the other. Both needs can be met by the SPOTLITE system which dramatically enhances the capability to rapidly engage hostile fire source with a minimum of casualties to friendly force and to innocent bystanders. Modular system design enable to meet each customer specific requirements and enable excellent future growth and upgrade potential. The design and built of a fire source detection system is governed by sets of requirements issued by the operators. This can be translated into the following design criteria: I) Long range, fast and accurate fire source detection capability. II) Different threat detection and classification capability. III) Threat investigation capability. IV) Fire source data distribution capability (Location, direction, video image, voice). V) Men portability. ) In order to meet these design criteria, an optimized concept was presented and exercised for the SPOTLITE system. Three major modular components were defined: I) Electro Optical Unit -Including FLIR camera, CCD camera, Laser Range Finder and Marker II) Electronic Unit -including system computer and electronic. III) Controller Station Unit - Including the HMI of the system. This article discusses the system's components definition and optimization processes, and also show how SPOTLITE designers successfully managed to introduce excellent solutions for other system parameters.

  20. Modular Power System Configured with Standard Product Hybrid DC-DC Converters Project

    Data.gov (United States)

    National Aeronautics and Space Administration — VPT proposes an innovative concept whereby complex NASA space power electronic systems can be configured using a small number of qualified hybrid DC-DC converter and...

  1. DYNAMIC CONFIGURATION OF THE COMPUTING NODES OF THE ALICE O2 SYSTEM

    CERN Document Server

    Pugdeethosapol, Krittaphat

    2015-01-01

    The ALICE (A Large Ion Collider Experiment) Collaboration is preparing major upgrades for the detectors in 2020 in order to take advantage of the increase of collision rate at up to 50 KHz in the LHC for Pb-Pb beams. Together with these upgrades, the ALICE Online and Offline computing systems are being redesigned and upgraded to a new common system called O2. The O2 system is made of a software framework and a computing facility. The concept of the framework consists of implementing an online reconstruction and archiving of the data of all reconstructed collisions to permanent data storage. The main objective is to achieve a high-throughput system on heterogeneous computing platforms. Our KMUTT team has taken the responsibility of designing of accomplishing the design of the Control, Configuration, and Monitoring (CCM) of the computing infrastructure. This thesis is focusing on Configuration. The configuration module should allow dynamic configuration of processes and environment parameters during runtime. ...

  2. Modular Power System Configured with Standard Product Hybrid DC-DC Converters Project

    Data.gov (United States)

    National Aeronautics and Space Administration — VPT proposes an innovative concept whereby complex, multiple-output, DC-DC converter systems can be configured through use of only 2 standard product hybrid DC-DC...

  3. A Component-Based Software Configuration Management Model and Its Supporting System

    Institute of Scientific and Technical Information of China (English)

    梅宏; 张路; 杨芙清

    2002-01-01

    Software configuration management (SCM) is an important key technology in software development. Component-based software development (CBSD) is an emerging paradigm in software development. However, to apply CBSD effectively in real world practice,supporting SCM in CBSD needs to be further investigated. In this paper, the objects that need to be managed in CBSD is analyzed and a component-based SCM model is presented. In this model, components, as the integral logical constituents in a system, are managed as the basic configuration items in SCM, and the relationships between/among components are defined and maintained. Based on this model, a configuration management system is implemented.

  4. Configuration Method Design for Reconfigurable Manufacturing System with the aid of Plant Simulation

    DEFF Research Database (Denmark)

    Li, Yang; Zhang, Shuai; Bilberg, Arne

    2014-01-01

    A new Reconfigurable Manufacturing System structure has been recently designed by a large consumer goods manufacturer in Europe, aiming to balance the performance of productivity and flexibility. This article shows an exploratory research on the (re)configuration procedure of the new RMS structure....... Following the procedure which is designed in this paper, the (re)configuration of RMS can be managed as part of the daily operation with the help of computer simulation. Keywords: Plant Simulation, Tecnomatix, Reconfigurable Manufacturing System, modular manufacturing....

  5. Optimal Configuration of Human Motion Tracking Systems: A Systems Engineering Approach

    Science.gov (United States)

    Henderson, Steve

    2005-01-01

    Human motion tracking systems represent a crucial technology in the area of modeling and simulation. These systems, which allow engineers to capture human motion for study or replication in virtual environments, have broad applications in several research disciplines including human engineering, robotics, and psychology. These systems are based on several sensing paradigms, including electro-magnetic, infrared, and visual recognition. Each of these paradigms requires specialized environments and hardware configurations to optimize performance of the human motion tracking system. Ideally, these systems are used in a laboratory or other facility that was designed to accommodate the particular sensing technology. For example, electromagnetic systems are highly vulnerable to interference from metallic objects, and should be used in a specialized lab free of metal components.

  6. A multi-perspective approach for the design of Product Configuration Systems - an evaluation of industry applications

    DEFF Research Database (Denmark)

    Hvam, Lars

    2004-01-01

    This article presents a suggested procedure for modelling and implementation of product configuration systems. The procedure has been applied in several industrial companies. The procedure comprises: • Analysis of the business processes to be supported by a product configuration system. Furthermore......, a de-marcation and definition of the configuration system to be designed. • Analysis and modelling of the part of the company’s product assortment which is to be included in the con-figuration system. • Selection of configuration software and programming of the configuration system. • Implementation...... of the configuration system. • Operations, maintenance and further development of the configuration system. The procedure has been developed on the basis of the general methods for modelling IT-systems (UML) as well as on the theory for modelling technical systems and theory for the development of business processes...

  7. Strategy Guideline. HVAC Equipment Sizing

    Energy Technology Data Exchange (ETDEWEB)

    Burdick, Arlan [IBACOS, Inc., Pittsburgh, PA (United States)

    2012-02-01

    This guide describes the equipment selection of a split system air conditioner and furnace for an example house in Chicago, IL as well as a heat pump system for an example house in Orlando, FL. The required heating and cooling load information for the two example houses was developed in the Department of Energy Building America Strategy Guideline: Accurate Heating and Cooling Load Calculations.

  8. A Test-Bed Configuration: Toward an Autonomous System

    Science.gov (United States)

    Ocaña, F.; Castillo, M.; Uranga, E.; Ponz, J. D.; TBT Consortium

    2015-09-01

    In the context of the Space Situational Awareness (SSA) program of ESA, it is foreseen to deploy several large robotic telescopes in remote locations to provide surveillance and tracking services for man-made as well as natural near-Earth objects (NEOs). The present project, termed Telescope Test Bed (TBT) is being developed under ESA's General Studies and Technology Programme, and shall implement a test-bed for the validation of an autonomous optical observing system in a realistic scenario, consisting of two telescopes located in Spain and Australia, to collect representative test data for precursor NEO services. In order to fulfill all the security requirements for the TBT project, the use of a autonomous emergency system (AES) is foreseen to monitor the control system. The AES will monitor remotely the health of the observing system and the internal and external environment. It will incorporate both autonomous and interactive actuators to force the protection of the system (i.e., emergency dome close out).

  9. Co-simulation of dynamic systems in parallel and serial model configurations

    Energy Technology Data Exchange (ETDEWEB)

    Sweafford, Trevor [General Motors, Milford (United States); Yoon, Hwan Sik [The University of Alabama, Tuscaloosa (United States)

    2013-12-15

    Recent advancement in simulation software and computation hardware make it realizable to simulate complex dynamic systems comprised of multiple submodels developed in different modeling languages. The so-called co-simulation enables one to study various aspects of a complex dynamic system with heterogeneous submodels in a cost-effective manner. Among several different model configurations for co-simulation, synchronized parallel configuration is regarded to expedite the simulation process by simulation multiple sub models concurrently on a multi core processor. In this paper, computational accuracies as well as computation time are studied for three different co-simulation frameworks : integrated, serial, and parallel. for this purpose, analytical evaluations of the three different methods are made using the explicit Euler method and then they are applied to two-DOF mass-spring systems. The result show that while the parallel simulation configuration produces the same accurate results as the integrated configuration, results of the serial configuration, results of the serial configuration show a slight deviation. it is also shown that the computation time can be reduced by running simulation in the parallel configuration. Therefore, it can be concluded that the synchronized parallel simulation methodology is the best for both simulation accuracy and time efficiency.

  10. Towards a Tool for Computer Supported Configuring of Machine Systems

    DEFF Research Database (Denmark)

    Hansen, Claus Thorp

    1996-01-01

    An engineering designer designing a product determines not only the product's component structure, but also a set of different structures which carry product behaviour and performance and make the product suited for its life phases. Whereas the nature of the elements of a machine system is fairly...

  11. A comparison of two commercial and the terminal configured vehicle area navigation systems

    Science.gov (United States)

    Knox, C. E.; Hartnell, D.

    1976-01-01

    A comparison was made of some of the more important features of two commercially available area navigation systems and the Terminal Configured Vehicle (TCV) area navigation system. Topics discussed included system design criteria, system elements, calculation of the navigation solution, and presentation of guidance information.

  12. NEXT Ion Propulsion System Configurations and Performance for Saturn System Exploration

    Science.gov (United States)

    Benson, Scott W.; Riehl, John P.; Oleson, Steven R.

    2007-01-01

    The successes of the Cassini/Huygens mission have heightened interest to return to the Saturn system with focused robotic missions. The desire for a sustained presence at Titan, through a dedicated orbiter and in-situ vehicle, either a lander or aerobot, has resulted in definition of a Titan Explorer flagship mission as a high priority in the Solar System Exploration Roadmap. The discovery of active water vapor plumes erupting from the tiger stripes on the moon Enceladus has drawn the attention of the space science community. The NASA's Evolutionary Xenon Thruster (NEXT) ion propulsion system is well suited to future missions to the Saturn system. NEXT is used within the inner solar system, in combination with a Venus or Earth gravity assist, to establish a fast transfer to the Saturn system. The NEXT system elements are accommodated in a separable Solar Electric Propulsion (SEP) module, or are integrated into the main spacecraft bus, depending on the mission architecture and performance requirements. This paper defines a range of NEXT system configurations, from two to four thrusters, and the Saturn system performance capability provided. Delivered mass is assessed parametrically over total trip time to Saturn. Launch vehicle options, gravity assist options, and input power level are addressed to determine performance sensitivities. A simple two-thruster NEXT system, launched on an Atlas 551, can deliver a spacecraft mass of over 2400 kg on a transfer to Saturn. Similarly, a four-thruster system, launched on a Delta 4050 Heavy, delivers more than 4000 kg spacecraft mass. A SEP module conceptual design, for a two thruster string, 17 kW solar array, configuration is characterized.

  13. VARIABLE SPEED INTEGRATED INTELLIGENT HVAC BLOWER

    Energy Technology Data Exchange (ETDEWEB)

    Herman Wiegman; Charlie Stephens; Xiaoyue Liu; Ralph Carl; Sunny Zhuang; Paul Szczesny; Kamron Wright

    2003-09-23

    This comprehensive topical report discusses the key findings in the development of an advanced blower for HVAC applications. The benefits of rearward inclined blades over that of traditional forward inclined blades is well documented, and several prototype wheels are demonstrated in various housings. A comparison of retrofitted blowers to that of three typical units from the industry is presented. The design and modification of the blower housing is addressed and the impact of size limitations on static efficiency is discussed. The roadmap to rearward-inclined wheel technology insertion is presented and typical static efficiency gains are documented.

  14. State of the Art of HVAC Technology in Europe and America

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.; Kazanci, Ongun Berk

    2015-01-01

    for increasing the energy efficiency of HVAC (heating, ventilation and air-conditioning) systems and for increasing the amount of renewable energy used. Especially these types of systems are getting increasing attention in Europe and North-America. In the present study, operation characteristics, possibilities...... mechanisms and media to emit and remove heat or moisture from indoor spaces (e.g. hydronic radiant heating and cooling systems, fan-coil units, and active beams). The main differences between HVAC systems in Europe, North America and other parts of the world are often the indoor terminal units. Type...... of energy sources and energy generators are very much similar. This paper will present state-of the art-off energy efficient systems that will provide a good indoor environmental quality at a decreased energy use. Low Temperature Heating and High Temperature Cooling systems are an important requirement...

  15. Configurational and energy landscape in one-dimensional Coulomb systems.

    Science.gov (United States)

    Varela, Lucas; Téllez, Gabriel; Trizac, Emmanuel

    2017-02-01

    We study a one-dimensional Coulomb system, where two charged colloids are neutralized by a collection of point counterions, with global neutrality. With temperature being given, two situations are addressed: Either the colloids are kept at fixed positions (canonical ensemble) or the force acting on the colloids is fixed (isobaric-isothermal ensemble). The corresponding partition functions are worked out exactly, in view of determining which arrangement of counterions is optimal. How many counterions should be in the confined segment between the colloids? For the remaining ions outside, is there a left-right symmetry breakdown? We evidence a cascade of transitions as system size is varied in the canonical treatment or as pressure is increased in the isobaric formulation.

  16. System configuration for advanced water management in power plants

    Energy Technology Data Exchange (ETDEWEB)

    Queirazza, G.; Sigon, F.; Zagano, C. [Ente Nazionale per l`Energia Elettrica, Milan (Italy)

    1995-12-01

    Water ie required for power plant operation and electricity generation. The water demand is steadily increasing depending on the enrgy pro-capite demand, the available or innovative technologies for power generation and the need for emissions control. Water management is also required to comply with the regulatory trends and it agrees with the guidelines for the sustainable development, as recommended at the Rio conference (Agenda 21). In order to assess the design and the operating alternatives for the water system of power plants and the impact of innovative technologies, a simulation code has been developed. The ENEL proprietary WATERSOFT code is presented in this paper. Some significant results will be presented and discussed, within the frame of improving the water management and optimizing the overall performances of the actual water systems.

  17. Real-Time Configuration of Networked Embedded Systems

    Science.gov (United States)

    2005-05-01

    Patashnik, Concrete Mathematics : A Foundation for Computer Science, 2nd ed. Reading, MA: Addison-Wesley, 1994. [22] G. Arfken , Mathematical Methods for...using simple graph methods (JAVA). The points were being read from a file. The interface was as shown below. 26 The second step was to create a...net- works of embedded systems require sound mathematical models that capture the probabilistic and dynamic character of these networks, including the

  18. Exergy analysis of scroll compressors working with R22, R407C, and R417A as refrigerant for HVAC system

    Directory of Open Access Journals (Sweden)

    Kalaiselvam Sivakumar

    2009-01-01

    Full Text Available The rise in crisis of power enthralls the world economically and the options for conventional and non-conventional energy resources have been searched out. No system exists in this world with 100% efficiency due to several irreversibility's. If the output obtained from the system is maximum for a given input, maximum amount of energy can be saved globally. To understand the thermodynamic losses occurring in the system and to predict the available energy that can be tapped from the system, exergy plays a major role. Experimental study on exergy in a system can pave the way to understand the complete behavior of the system exergually. Conceptually exergy studies are based on simulation, to provide a new dimension to the concept of exergy experimental validation have been promoted. The analogy of exergy analysis of three refrigerants working in scroll compressors and their exergual features are explained in this paper. The refrigerants R22, R417A, and R407C and their thermo dynamical behavior, irreversibility were experimented in an air conditioning system with three scroll compressors, interaction between the system and the refrigerant in terms of pressure drop and heat transfer, friction has been implemented for the calculation of exergy. The entire system performance on the basis of refrigerant is validated in each part of the air conditioning system. The resultant coefficient of performance of R407C is 2.41% less than R22 in a R22 designed scroll compressor with minimal exergy losses. The second law efficiency of 50 to 55% obtained in R22 has fewer rules over R407C and R417A which has 48 to 52%. The diminutive deviation of results encourages R417A refrigerant to be used as a substitute for R22. Thus the exergual prediction of performance of refrigerant and second law efficiency can identify the use of eco-friendly refrigerant in scroll compressor.

  19. An Adaptive Filtering System Configurations and Architecture on Reconfigurable Platform

    Directory of Open Access Journals (Sweden)

    Dipen B. Patel

    2014-03-01

    Full Text Available This paper proposed the implementation of adaptive filters on reconfigurable platform. Adaptive filter is an essential part of digital signal systems, have been widely used and its implementation takes a great deal, there is no dedicated IC for adaptive filter. When FPGA implemented in such area, provides a lot of facilities to the designers and also offer a better solution for filtering the data. Adaptive signal processing evolved from the techniques developed to enable the adaptive control of time- varying systems. Filtering data in real-time requires dedicated hardware to meet demanding time requirements and provide the highest processing performance, but is inflexible for changes. When a design demands the use of a DSP, design adaptability is crucial, then FPGA may offer a better solution. Reconfigurable hardware devices offer both the flexibility of computer software, and the ability to construct custom high performance computing circuits. Adaptive filter implemented using Field Programmable Gate Arrays (FPGAs due to some of their attractive advantages include flexibility and programmability, availability of tens to hundreds of hardware multipliers available on a chip. Keywords -

  20. Novel configurations of solar distillation system for potable water production

    Science.gov (United States)

    Riahi, A.; Yusof, K. W.; Sapari, N.; Singh, B. S.; Hashim, A. M.

    2013-06-01

    More and more surface water are polluted with toxic chemicals. Alternatively brackish and saline water are used as feed water to water treatment plants. Expensive desalination process via reverse osmosis or distillation is used in the plants. Thus, this conventional desalination is not suitable for low and medium income countries. A cheaper method is by solar distillation. However the rate of water production by this method is generally considered low. This research attempts to enhance water production of solar distillation by optimizing solar capture, evaporation and condensation processes. Solar radiation data was captured in several days in Perak, Malaysia. Three kinds of experiments were done by fabricating triangular solar distillation systems. First type was conventional solar still, second type was combined with 50 Watt solar photovoltaic panel and 40 Watt Dc heater, while third type was integrated with 12 Volt Solar battery and 40 Watt Dc heater. The present investigation showed that the productivity of second and third systems were 150% and 480% of the conventional still type, respectively. The finding of this research can be expected to have wide application in water supply particularly in areas where fresh surface water is limited.

  1. Computer software configuration description, 241-AY and 241-AZ tank farm MICON automation system

    Energy Technology Data Exchange (ETDEWEB)

    Winkelman, W.D.

    1998-01-08

    This document describes the configuration process, choices and conventions used during the configuration activities, and issues involved in making changes to the configuration. Includes the master listings of the Tag definitions, which should be revised to authorize any changes. Revision 2 incorporates minor changes to ensure the document setpoints accurately reflect limits (including exhaust stack flow of 800 scfm) established in OSD-T-151-00019. The MICON DCS software controls and monitors the instrumentation and equipment associated with plant systems and processes.

  2. AZ-101 Mixer Pump Demonstration Data Acquisition System and Gamma Cart Data Acquisition Control System Software Configuration Management Plan

    Energy Technology Data Exchange (ETDEWEB)

    WHITE, D.A.

    1999-12-29

    This Software Configuration Management Plan (SCMP) provides the instructions for change control of the AZ1101 Mixer Pump Demonstration Data Acquisition System (DAS) and the Sludge Mobilization Cart (Gamma Cart) Data Acquisition and Control System (DACS).

  3. Data configurations in railway signalling engineering - an application of enterprise systems techniques

    Science.gov (United States)

    Chen, Xiangxian; Guan, Aiai; Qiu, Xinxi; Huang, Hai; Liu, Jiquan; Duan, Huilong

    2013-08-01

    Railway signalling system is a safety-critical system to ensure railway safety and its development cost is huge. It is of great economic value to apply the generic signalling systems in different environments through configuration of different application data. In this paper, a new method to configure the application data completely and accurately is illustrated; in particular, a technique called automatic generation technology is introduced to automatically configure the functional logic of safety-critical systems, i.e. computer-based interlocking (CBI) system and automatic train protection (ATP) system. All of the application data are collected from the workflow among various departments through the enterprise system (ES). Some application data are represented by models employing automatic generation technology, and the functional logic is then obtained through analysis using these models. A configuration platform based on the ES is developed in which both the efficiency and accuracy of the application data configuration are significantly improved. In addition, it is capable of reducing human errors to a maximal extent.

  4. The Effects of Set-Points and Dead-Bands of the HVAC System on the Energy Consumption and Occupant Thermal Comfort

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Olesen, Bjarne W.

    2013-01-01

    with a ground heat exchanger, a ground coupled heat pump, embedded pipes in the floor and in the ceiling, a ventilation system (mechanical and natural), a domestic hot water tank and photovoltaic/thermal panels on the roof. Preliminary evaluations showed that for Madrid, change of indoor set-point in cooling......A building is a complex system where many components interact with each other therefore the control system plays a key role regarding the energy consumption and the occupant thermal comfort. This study is concerned with a detached, one-storey, single family, energy-plus house. It is equipped...... on the effects of the set-points and dead-bands of different components on the energy consumption together with the occupant thermal comfort. Evaluations are carried out with TRNSYS for Copenhagen and Madrid in order to compare climatic effects....

  5. Performance monitoring of different module technologies and design configurations of PV system in South Africa

    CSIR Research Space (South Africa)

    Roro, Kittessa T

    2016-06-01

    Full Text Available Performance monitoring of different module technologies and system configurations of Photovoltaic (PV) systems in South Africa is rare, resulting in-few reports based on field results of PV systems installed and operated in South Africa. The goal...

  6. Comparison between design and actual energy performance of a HVAC-ground coupled heat pump system in cooling and heating operation

    Energy Technology Data Exchange (ETDEWEB)

    Magraner, T.; Quilis, S. [Energesis Ingenieria S.L., Ciudad Politecnica de la Innovacion, Camino de Vera s/n, 46022 Valencia (Spain); Montero, A. [Instituto de Ingenieria Energetica, Universidad Politecnica de Valencia, Camino de Vera s/n, 46022 Valencia (Spain); Urchueguia, J.F. [Instituto Universitario de Matematica Pura y Aplicada, Universidad Politecnica de Valencia, Camino de Vera s/n, 46022 Valencia (Spain)

    2010-09-15

    This work compares the experimental results obtained for the energy performance study of a ground coupled heat pump system with the design values predicted by means of standard methodology. The system energy performance of a monitored ground coupled heat pump system is calculated using the instantaneous measurements of temperature, flow and power consumption and these values are compared with the numerical predictions. These predictions are performed with the TRNSYS software tool following standard procedures taking the experimental thermal loads as input values. The main result of this work is that simulation results solely based on nominal heat pump capacities and performances overestimate the measured overall energy performance by a percentage between 15% and 20%. A sensitivity analysis of the simulation results to changes in percentage of its input parameters showed that the heat pump nominal coefficient of performance is the parameter that mostly affects the energy performance predictions. This analysis supports the idea that the discrepancies between experimental results and simulation outputs for this ground coupled system are mainly due to heat pump performance degradation for being used at partial load. An estimation of the impact of this effect in energy performance predictions reduces the discrepancies to values around 5%. (author)

  7. An advanced configuration management system for full scope power plant simulators

    Energy Technology Data Exchange (ETDEWEB)

    Storm, J.; Goemann, A. [STN ATLAS Elektronik, Bremen (Germany)

    1996-11-01

    In August 1993 KSG Kraftwerks-Simulator-Gesellschaft, Germany, awarded a contract to STN ATLAS Elektronik for the delivery of two full scope replica training simulators for the German BWR plants Isar 1 and Philipsburg 1, known as the double simulator project S30 (S31/S32). For both projects a computer based Configuration Management System (CMS) was required to overcome deficiencies of older simulator systems in terms of limited upgrade and maintenance capabilities and incomplete documentation. The CMS allows complete control over the entire simulator system covering all software- and hardware-items and therewith exceed quality assurance requirements as defined in ISO 9000-3 which gives recommendations for software configuration management only. The system is realized under the project using the UNIX based relational database system EMPRESS and is in use as a development- and maintenance-tool to improve simulator quality and ensure simulator configuration integrity.

  8. Energy conservation in space HVAC systems. Improving specific blower performance with leaktight air ducts; Energieeinsparung in RLT-Anlagen. Verbesserung der spezifischen Ventilatorleistung mit dichteren Luftleitungen

    Energy Technology Data Exchange (ETDEWEB)

    Luft, J. [Lindab GmbH, Bargteheide (Germany)

    2005-07-01

    The 91 goals stated in the Energy Performance of Buildings Directive (EPBD) 2002/91 are implemented in German law by the Energy Conservation Ordinance and further standards and regulations. In the case of ventilation and air conditioning systems, DIN EN 13779 applies, in which a SFP (specific fan power) value is introduced. The contribution shows how leaktightness of air ducts will affect the SFP. (orig.)

  9. NPIP: A skew line needle configuration optimization system for HDR brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Siauw, Timmy; Cunha, Adam; Berenson, Dmitry; Atamtuerk, Alper; Hsu, I-Chow; Goldberg, Ken; Pouliot, Jean [Department of Civil and Environmental Engineering, University of California, Berkeley, 760 Davis Hall, Berkeley, California 94720-1710 (United States); Department of Radiation Oncology, University of California, San Francisco, Comprehensive Cancer Center, 1600 Divisadero Street, Suite H1031, San Francisco, California 94143-1708 (United States); Department of Electrical Engineering and Computer Science, University of California, Berkeley, 4th Floor Sutardja Dai Hall, Berkeley, California 94720-1764 (United States); Department of Industrial Engineering and Operations, University of California, Berkeley, 4141 Etcheverry Hall, Berkeley, California 94720-1777 (United States); Department of Radiation Oncology, University of California, San Francisco, Comprehensive Cancer Center, 1600 Divisadero Street, Suite H1031, San Francisco, California 94143-1708 (United States); Department of Industrial Engineering and Operations Research and Department of Electrical Engineering and Computer Science, University of California, Berkeley, 4141 Etcheverry Hall, Berkeley, California 94720-1777 (United States); Department of Radiation Oncology, University of California, San Francisco, Comprehensive Cancer Center, 1600 Divisadero Street, Suite H1031, San Francisco, California 94143-1708 (United States)

    2012-07-15

    Purpose: In this study, the authors introduce skew line needle configurations for high dose rate (HDR) brachytherapy and needle planning by integer program (NPIP), a computational method for generating these configurations. NPIP generates needle configurations that are specific to the anatomy of the patient, avoid critical structures near the penile bulb and other healthy structures, and avoid needle collisions inside the body. Methods: NPIP consisted of three major components: a method for generating a set of candidate needles, a needle selection component that chose a candidate needle subset to be inserted, and a dose planner for verifying that the final needle configuration could meet dose objectives. NPIP was used to compute needle configurations for prostate cancer data sets from patients previously treated at our clinic. NPIP took two user-parameters: a number of candidate needles, and needle coverage radius, {delta}. The candidate needle set consisted of 5000 needles, and a range of {delta} values was used to compute different needle configurations for each patient. Dose plans were computed for each needle configuration. The number of needles generated and dosimetry were analyzed and compared to the physician implant. Results: NPIP computed at least one needle configuration for every patient that met dose objectives, avoided healthy structures and needle collisions, and used as many or fewer needles than standard practice. These needle configurations corresponded to a narrow range of {delta} values, which could be used as default values if this system is used in practice. The average end-to-end runtime for this implementation of NPIP was 286 s, but there was a wide variation from case to case. Conclusions: The authors have shown that NPIP can automatically generate skew line needle configurations with the aforementioned properties, and that given the correct input parameters, NPIP can generate needle configurations which meet dose objectives and use as many

  10. Principle of Line Configuration and Monte-Carlo Simulation for Shared Multi-Channel System

    Institute of Scientific and Technical Information of China (English)

    MIAO Changyun; DAI Jufeng; BAI Zhihui

    2005-01-01

    Based on the steady-state solution of finite-state birth and death process, the principle of line configuration for shared multi-channel system is analyzed. Call congestion ratio equation and channel utilization ratio equation are deduced, and visualized data analysis is presented. The analy-sis indicates that, calculated with the proposed equations, the overestimate for call congestion ratio and channel utilization ratio can be rectified, and thereby the cost of channels can be saved by 20% in a small system.With MATLAB programming, line configuration methods are provided. In order to generally and intuitively show the dynamic running of the system, and to analyze,promote and improve it, the system is simulated using M/M/n/n/m queuing model and Monte-Carlo method. In addition, the simulation validates the correctness of the theoretical analysis and optimizing configuration method.

  11. Control And Configuration Of The ATLAS Trigger And Data Acquisition System During Data Taking Activities

    CERN Document Server

    Bianchi, R M; The ATLAS collaboration

    2011-01-01

    The ATLAS experiment at the Large Hadron Collider at CERN relies on a complex and highly distributed Trigger and Data Acquisition (TDAQ) system to gather and select particle collision data at unprecedented energy and rates. The control and configuration (CC) system is responsible for all the software required to configure and control the ATLAS data taking. This ranges from high level applications, such as the graphical user interfaces and the desktops used within the ATLAS control room, to low level packages, such as access, process and resource management. Currently the CC system is required to supervise more than 15000 processes running on more than 1500 computers. At these scales, issues such as access, process and resource management, distribution of configuration data and access to them, run control, diagnostic and especially error recovery become predominant to guarantee a high availability of the TDAQ system and minimize the dead time of the experiment. And it is indeed during the data taking activitie...

  12. Control configuration selection for bilinear systems via generalised Hankel interaction index array

    DEFF Research Database (Denmark)

    Shaker, Hamid Reza; Tahavori, Maryamsadat

    2015-01-01

    of the results on control configuration selection, which have been proposed so far, can only support linear systems. The proposed method supports bilinear processes, takes the effects of dynamics of the process into account and can be used to propose a richer (sparse or block diagonal) controller structure. More......Decentralised and partially decentralised control strategies are very popular in practice. To come up with a suitable decentralised or partially decentralised control structure, it is important to select the appropriate input and output pairs for control design. This procedure is called control...... configuration selection. It is well known that a suitable control configuration selection is an important prerequisite for a successful industrial control. In this paper the problem of control configuration selection for multiple-input and multiple-output (MIMO) bilinear processes is addressed. First...

  13. HVAC system design for Beijing Chao-Yang Hospital%北京朝阳医院暖通空调系统设计

    Institute of Scientific and Technical Information of China (English)

    赵文成

    2013-01-01

    Combined with state-of-the-art medical processes, allocates ventilation and air conditioning systems rationally and determines the positive and negative pressure of different rooms, the pressure gradient of clean rooms and the air flow direction, providing a reliable guarantee against cross-infection within the hospital. The project constructs the first domestic clean respiratory intensive care unit (RICU), the chemical poisoning emergency treatment center and the emergency center with A, B. C three zones admissions and treatment mechanism. Expounds their ventilation and air conditioning design.%结合先进的医疗流程,合理配置了通风空调系统,明确设计了房间的正负压、净化房间的压力梯度及气流流向,为防止医院内交叉感染提供了可靠的保证.该工程设计建成了国内首个净化的RICU和化学中毒紧急救治中心,急救中心分成A,B,C三区接诊及救治,详细介绍了这些场所的通风空调设计.

  14. Improving performance of HVAC systems to reduce exposure to aerosolized infectious agents in buildings; recommendations to reduce risks posed by biological attacks.

    Science.gov (United States)

    Hitchcock, Penny J; Mair, Michael; Inglesby, Thomas V; Gross, Jonathan; Henderson, D A; O'Toole, Tara; Ahern-Seronde, Joa; Bahnfleth, William P; Brennan, Terry; Burroughs, H E Barney; Davidson, Cliff; Delp, William; Ensor, David S; Gomory, Ralph; Olsiewski, Paula; Samet, Jonathan M; Smith, William M; Streifel, Andrew J; White, Ronald H; Woods, James E

    2006-01-01

    The prospect of biological attacks is a growing strategic threat. Covert aerosol attacks inside a building are of particular concern. In the summer of 2005, the Center for Biosecurity of the University of Pittsburgh Medical Center convened a Working Group to determine what steps could be taken to reduce the risk of exposure of building occupants after an aerosol release of a biological weapon. The Working Group was composed of subject matter experts in air filtration, building ventilation and pressurization, air conditioning and air distribution, biosecurity, building design and operation, building decontamination and restoration, economics, medicine, public health, and public policy. The group focused on functions of the heating, ventilation, and air conditioning systems in commercial or public buildings that could reduce the risk of exposure to deleterious aerosols following biological attacks. The Working Group's recommendations for building owners are based on the use of currently available, off-the-shelf technologies. These recommendations are modest in expense and could be implemented immediately. It is also the Working Group's judgment that the commitment and stewardship of a lead government agency is essential to secure the necessary financial and human resources and to plan and build a comprehensive, effective program to reduce exposure to aerosolized infectious agents in buildings.

  15. A prototype of a documentation system that supports the development and maintenance of product configuration systems

    DEFF Research Database (Denmark)

    Haug, Anders; Degn, Anders; Poulsen, Bjarne

    2007-01-01

    , no software exists which supports all three techniques in an integrated fashion. This means that when developing PCSs based on this procedure there is no automatic integration between the created models. Therefore, for some years, researchers have worked on creating a basis for developing a documentation......, such as shorter lead times, reductions of resources needed and fewer errors. A procedure for the development and maintenance of PCSs, which has been applied in configuration projects for more than ten years, includes three main modelling techniques to support the development and maintenance of PCSs. Unfortunately...... system that supports the development and maintenance of PCSs. This article describes how some of this research has been converted into a prototype of a documentation system and what has been learned from the evaluation of the prototype...

  16. Self-Correcting HVAC Controls Project Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, Nicholas; Brambley, Michael R.; Katipamula, Srinivas; Cho, Heejin; Goddard, James K.; Dinh, Liem H.

    2010-01-04

    This document represents the final project report for the Self-Correcting Heating, Ventilating and Air-Conditioning (HVAC) Controls Project jointly funded by Bonneville Power Administration (BPA) and the U.S. Department of Energy (DOE) Building Technologies Program (BTP). The project, initiated in October 2008, focused on exploratory initial development of self-correcting controls for selected HVAC components in air handlers. This report, along with the companion report documenting the algorithms developed, Self-Correcting HVAC Controls: Algorithms for Sensors and Dampers in Air-Handling Units (Fernandez et al. 2009), document the work performed and results of this project.

  17. The Relationship between Strategic Information Systems Planning Situational Factors, Process Configuration and Success

    NARCIS (Netherlands)

    Gilbert Gilbert Silvius; Jeroen Stoop

    2013-01-01

    This paper reports a study into the relationship between the configuration of the process of Strategic Information Systems Planning (SISP) and the success of SISP. SISP is an important activity in the alignment of information technology systems and services to business requirements. However, despite

  18. The Relationship between Strategic Information Systems Planning Situational Factors, Process Configuration and Success

    NARCIS (Netherlands)

    Silvius, Gilbert; Stoop, Jeroen

    2013-01-01

    This paper reports a study into the relationship between the configuration of the process of Strategic Information Systems Planning (SISP) and the success of SISP. SISP is an important activity in the alignment of information technology systems and services to business requirements. However, despite

  19. Modelling Product Families for Product Configuration Systems with Product Variant Master

    DEFF Research Database (Denmark)

    Mortensen, Niels Henrik; Hvam, Lars; Haug, Anders

    2010-01-01

    developed in cooperation with several industrial companies. This article refers to experiences from applying the modelling technique in three different companies. Based upon these experiences, the utility of the product variant master and CRC-cards is evaluated. Significance. Product configuration systems...... are increasingly used in industrial companies as a means for efficient design of customer tailored products. The design and implementation of product configuration systems is a new and challenging task for the industrial companies and calls for a scientifically based framework to support the modelling......This article presents an evaluation of applying a suggested method for modelling product families for product configuration based on theory for modelling mechanical products,systems theory and object-oriented modelling. The modelling technique includes a so-called product variant master and CRC...

  20. A multi perspective approach for the design of product configuration systems

    DEFF Research Database (Denmark)

    Hvam, Lars

    2004-01-01

    This article presents a procedure for building product configuration systems. The procedure includes, as the first phase, an analysis and redesign of the business processes, which are to be supported with product configuration systems. The next phase includes an analysis of the product assortment......, and the set up of a so-called product variant master. Finally the product configuration system is designed and implemented using object oriented modeling. The procedure has been tested in several companies. This article includes the experiences from the most recent project, which has been carried out at Demex...... Electric – a Danish company making electronic switchboards. The research has been carried out at the Centre for Product Modelling, Department of Manufacturing Engineering and Management at the Technical University of Denmark....

  1. Development and maintenance of product configuration systems: Requirements for a documentation tool

    DEFF Research Database (Denmark)

    Hvam, Lars; Christensen, Simon Pape; Jensen, Klaes Ladeby

    2005-01-01

    of the most essential tasks is thus to develop a complete and consistent product model which can reflect the actual product. A procedure for building configuration systems has been developed at the Centre for Product Modelling (CPM), and the procedure has been successfully applied in several industrial...... companies. CPM's experience with the procedure and the hitherto empirical experience from companies having applied the procedure have revealed that there is a need for an IT-based documentation tool to support the process of constructing and maintaining product configuration systems. Time can be saved......) technology to support the documentation process. This paper deals with the requirement specification of a documentation tool for product configuration systems, based on CPM's procedure and experience from four Danish industrial companies which have applied the procedure. The requirements have been gathered...

  2. A multi perspective approach for the design of product configuration systems

    DEFF Research Database (Denmark)

    Hvam, Lars

    2004-01-01

    , and the set up of a so-called product variant master. Finally the product configuration system is designed and implemented using object oriented modeling. The procedure has been tested in several companies. This article includes the experiences from the most recent project, which has been carried out at Demex......This article presents a procedure for building product configuration systems. The procedure includes, as the first phase, an analysis and redesign of the business processes, which are to be supported with product configuration systems. The next phase includes an analysis of the product assortment...... Electric – a Danish company making electronic switchboards. The research has been carried out at the Centre for Product Modelling, Department of Manufacturing Engineering and Management at the Technical University of Denmark....

  3. Smart HVAC Control in IoT: Energy Consumption Minimization with User Comfort Constraints

    Directory of Open Access Journals (Sweden)

    Jordi Serra

    2014-01-01

    of heating, ventilation, and air conditioning (HVAC systems in smart grids with variable energy price. To that end, first, we propose an energy scheduling method that minimizes the energy consumption cost for a particular time interval, taking into account the energy price and a set of comfort constraints, that is, a range of temperatures according to user’s preferences for a given room. Then, we propose an energy scheduler where the user may select to relax the temperature constraints to save more energy. Moreover, thanks to the IoT paradigm, the user may interact remotely with the HVAC control system. In particular, the user may decide remotely the temperature of comfort, while the temperature and energy consumption information is sent through Internet and displayed at the end user’s device. The proposed algorithms have been implemented in a real testbed, highlighting the potential gains that can be achieved in terms of both energy and cost.

  4. A Statistical Approach for Selecting Buildings for Experimental Measurement of HVAC Needs

    Directory of Open Access Journals (Sweden)

    Malinowski Paweł

    2017-03-01

    Full Text Available This article presents a statistical methodology for selecting representative buildings for experimentally evaluating the performance of HVAC systems, especially in terms of energy consumption. The proposed approach is based on the k-means method. The algorithm for this method is conceptually simple, allowing it to be easily implemented. The method can be applied to large quantities of data with unknown distributions. The method was tested using numerical experiments to determine the hourly, daily, and yearly heat values and the domestic hot water demands of residential buildings in Poland. Due to its simplicity, the proposed approach is very promising for use in engineering applications and is applicable to testing the performance of many HVAC systems.

  5. Practical Study on HVAC Control Technology Based on the Learning Function and Optimum Multiple Objective Processes

    Science.gov (United States)

    Ueda, Haruka; Dazai, Ryota; Kaseda, Chosei; Ikaga, Toshiharu; Kato, Akihiro

    Demand among large office buildings for the energy-saving benefits of the HVAC (Heating, Ventilating and Air-Conditioning) System are increasing as more and more people become concerned with global environmental issues. However, immoderate measures taken in the interest of energy conservation may encroach on the thermal comfort and productivity level of office workers. Building management should satisfy both indoor thermal comfort and energy conservation while adapting to the many regulatory, social, climate, and other changes that occur during the lifespan of the building. This paper demonstrates how optimal control of the HVAC system, based on data modeling and the multi-objective optimal method, achieves an efficient equilibrium between thermal comfort and energy conservation.

  6. Jet engine nozzle exit configurations, including projections oriented relative to pylons, and associated systems and methods

    Science.gov (United States)

    Mengle, Vinod G. (Inventor); Thomas, Russell H. (Inventor)

    2012-01-01

    Nozzle exit configurations and associated systems and methods are disclosed. An aircraft system in accordance with one embodiment includes a jet engine exhaust nozzle having an internal flow surface and an exit aperture, with the exit aperture having a perimeter that includes multiple projections extending in an aft direction. Aft portions of individual neighboring projections are spaced apart from each other by a gap, and a geometric feature of the multiple can change in a monotonic manner along at least a portion of the perimeter. Projections near a support pylon and/or associated heat shield can have particular configurations, including greater flow immersion than other projections.

  7. DEVELOPMENT OF THE OPTIMAL CONTROL MODEL FOR HVAC SYSTEM AND ITS APPLICATION%通风空调系统最优控制模型的开发及应用

    Institute of Scientific and Technical Information of China (English)

    刘贤坤; 董超俊

    2002-01-01

    对某一通风空调(HVAC)系统进行了实验,利用实验结果采用多变量自回归的方法开发了适用于HVAC系统控制的数学模型,该数字模型用于带有前馈补偿的线性二次高斯控制(LQG),控制房间的温度和湿度,大大改善了控制性能,提高了HVAC系统的稳定性.

  8. Configuration maintaining control of three-body ring tethered system based on thrust compensation

    Science.gov (United States)

    Huang, Panfeng; Liu, Binbin; Zhang, Fan

    2016-06-01

    Space multi-tethered systems have shown broad prospects in remote observation missions. This paper mainly focuses on the dynamics and configuration maintaining control of space spinning three-body ring tethered system for such mission. Firstly, we establish the spinning dynamic model of the three-body ring tethered system considering the elasticity of the tether using Newton-Euler method, and then validate the suitability of this model by numerical simulation. Subsequently, LP (Likins-Pringle) initial equilibrium conditions for the tethered system are derived based on rigid body's equilibrium theory. Simulation results show that tether slack, snapping and interaction between the tethers exist in the three-body ring system, and its' configuration can not be maintained without control. Finally, a control strategy based on thrust compensation, namely thrust to simulate tether compression under LP initial equilibrium conditions is designed to solve the configuration maintaining control problem. Control effects are verified by numerical simulation compared with uncontrolled situation. Simulation results show that the configuration of the three-body ring tethered system could maintain under this active control strategy.

  9. Efficient HVAC. New products; Climatización eficiente. Nuevos productos

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-07-01

    Jung is responding to the challenge of energy efficiency, ease of operation and economic profitability in all of its solutions for the tertiary sector, whether for newly constructed buildings or refurbishments, for full management of the electrical system or the partial control of lighting, HVAC, mood settings, access control, etc., for the bedrooms or specific areas of the building. In the specific case of hotels, Jung offers each a custom-made solution in line with its possibilities and objectives. (Author)

  10. How to Analyze and Quantify Similarities between Configured Engineer-To-Order Products by Comparing the Highlighted Features Utilizing the Configuration System Abilities

    DEFF Research Database (Denmark)

    Shafiee, Sara; Hvam, Lars; Kristjansdottir, Katrin

    2015-01-01

    the engineering hours and to improve the accuracy of the product specifications. In this article we suggest a framework where product features from the company’s configuration system are listed up in order to compare with previously made products by retrieving information from internal ERP/PLM systems. The list...

  11. Designing Forced-Air HVAC Systems

    Energy Technology Data Exchange (ETDEWEB)

    None

    2010-08-31

    This guide explains proper calculation of heating and cooling design loads for homes.used to calculated for the home using the protocols set forth in the latest edition of the Air Conditioning Contractors of America’s (ACCA) Manual J (currently the 8th edition), ASHRAE 2009 Handbook of Fundamentals, or an equivalent computation procedure.

  12. Choosing a Geothermal as an HVAC System.

    Science.gov (United States)

    Lensenbigler, John D.

    2002-01-01

    Describes the process of selecting and installing geothermal water source heat pumps for new residence halls at Johnson Bible College in Knoxville, Tennessee, including choosing the type of geothermal design, contractors, and interior equipment, and cost and payback. (EV)

  13. Choosing a Geothermal as an HVAC System.

    Science.gov (United States)

    Lensenbigler, John D.

    2002-01-01

    Describes the process of selecting and installing geothermal water source heat pumps for new residence halls at Johnson Bible College in Knoxville, Tennessee, including choosing the type of geothermal design, contractors, and interior equipment, and cost and payback. (EV)

  14. Inviscid and viscous flow modelling of complex aircraft configurations using the CFD simulation system sauna

    Science.gov (United States)

    Peace, Andrew J.; May, Nicholas E.; Pocock, Mark F.; Shaw, Jonathon A.

    1994-04-01

    This paper is concerned with the flow modelling capabilities of an advanced CFD simulation system known by the acronym SAUNA. This system is aimed primarily at complex aircraft configurations and possesses a unique grid generation strategy in its use of block-structured, unstructured or hybrid grids, depending on the geometric complexity of the addressed configuration. The main focus of the paper is in demonstrating the recently developed multi-grid, block-structured grid, viscous flow capability of SAUNA, through its evaluation on a number of configurations. Inviscid predictions are also presented, both as a means of interpreting the viscous results and with a view to showing more completely the capabilities of SAUNA. It is shown that accuracy and flexibility are combined in an efficient manner, thus demonstrating the value of SAUNA in aerodynamic design.

  15. Verification of the CFD simulation system SAUNA for complex aircraft configurations

    Science.gov (United States)

    Shaw, Jonathon A.; Peace, Andrew J.; May, Nicholas E.; Pocock, Mark F.

    1994-04-01

    This paper is concerned with the verification for complex aircraft configurations of an advanced CFD simulation system known by the acronym SAUNA. A brief description of the complete system is given, including its unique use of differing grid generation strategies (structured, unstructured or both) depending on the geometric complexity of the addressed configuration. The majority of the paper focuses on the application of SAUNA to a variety of configurations from the military aircraft, civil aircraft and missile areas. Mesh generation issues are discussed for each geometry and experimental data are used to assess the accuracy of the inviscid (Euler) model used. It is shown that flexibility and accuracy are combined in an efficient manner, thus demonstrating the value of SAUNA in aerodynamic design.

  16. Strategy Guideline: Transitioning HVAC Companies to Whole House Performance Contractors

    Energy Technology Data Exchange (ETDEWEB)

    Burdick, A.

    2012-05-01

    This report describes the findings from research IBACOS conducted related to heating, ventilation, and air conditioning (HVAC) companies who have made the decision to transition to whole house performance contracting (WHPC).

  17. Strategy Guideline. Transitioning HVAC Companies to Whole House Performance Contractors

    Energy Technology Data Exchange (ETDEWEB)

    Burdick, Arlan [IBACOS, Inc., Pittsburgh, PA (United States)

    2012-05-01

    This report describes the findings from research IBACOS conducted related to heating, ventilation, and air conditioning (HVAC) companies who have made the decision to transition to whole house performance contracting (WHPC).

  18. The HVAC Control Technology Making Energy Saving Compatible with Comfort

    National Research Council Canada - National Science Library

    高木, 康夫; 米沢, 憲造; 村山, 大; 西村, 信孝; 花田, 雄一; 山崎, 謙一

    2010-01-01

    .... The method is mainly focused on the compatibility of energy savings and comfort. The energy saving is achieved through the next generation air handling unit that controls room humidity without energy loss and the optimal operation of HVAC...

  19. Correlation as a determinant of configurational entropy in supramolecular and protein systems.

    Science.gov (United States)

    Fenley, Andrew T; Killian, Benjamin J; Hnizdo, Vladimir; Fedorowicz, Adam; Sharp, Dan S; Gilson, Michael K

    2014-06-19

    For biomolecules in solution, changes in configurational entropy are thought to contribute substantially to the free energies of processes like binding and conformational change. In principle, the configurational entropy can be strongly affected by pairwise and higher-order correlations among conformational degrees of freedom. However, the literature offers mixed perspectives regarding the contributions that changes in correlations make to changes in configurational entropy for such processes. Here we take advantage of powerful techniques for simulation and entropy analysis to carry out rigorous in silico studies of correlation in binding and conformational changes. In particular, we apply information-theoretic expansions of the configurational entropy to well-sampled molecular dynamics simulations of a model host-guest system and the protein bovine pancreatic trypsin inhibitor. The results bear on the interpretation of NMR data, as they indicate that changes in correlation are important determinants of entropy changes for biologically relevant processes and that changes in correlation may either balance or reinforce changes in first-order entropy. The results also highlight the importance of main-chain torsions as contributors to changes in protein configurational entropy. As simulation techniques grow in power, the mathematical techniques used here will offer new opportunities to answer challenging questions about complex molecular systems.

  20. CONFIGURATION CONTROLLABILITY FOR NON-ZERO POTENTIAL MECHANICAL CONTROL SYSTEMS WITH DISSIPATION

    Institute of Scientific and Technical Information of China (English)

    KANG Jian-ling; WANG Hong; YE Hua-wen

    2005-01-01

    Within the affine connection framework of Lagrangian control systems, based on the results of Sussmann on controllability of general affine control systems defined on a finite-dimensional manifold, a computable sufficient condition of configuration controllability for the simple mechanical control systems was extended to the case of systems with strictly dissipative energy terms of linear isotropic nature, and a sufficient condition of equilibrium controllability for the systems was also given, where Lagrangian is kinetic energy minus potential energy. Lie bracketting of vector fields in controllable Lie algebra, and the symmetric product associated with Levi-Civita connection show virtues in the discussion. Liouville vector field simplified the computation of controllable Lie algebra for the systems, although the terms of potential energy complicated the study of configuration controllability.

  1. Retaining rooted operations capabilities in footloose supply networks – the system cluster configuration

    DEFF Research Database (Denmark)

    Søberg, Peder Veng; Wæhrens, Brian Vejrum

    2014-01-01

    Original Equipment Manufacturer (OEM) customers feel a need to realize the benefits of outsourcing, while maintaining the development force, which can easily be lost, if too much is outsourced. The paper illustrates the innovative value chain configurationsystem cluster”, in which suppliers and...

  2. Information Management System training in the conditions of application configurations "1C: Enterprise"

    Directory of Open Access Journals (Sweden)

    Sergei Bogatenkov

    2014-04-01

    Full Text Available Introduction of information technology increases the efficiency of solving professional problems and to increase the role of information training. The article describes a system of information training in the conditions of application configurations "1C: Enterprise" based on the classification of staff according to their level of training and quality requirements, including the availability of appropriate certificates of 1C.

  3. On the configuration of systems of interacting particle with minimum potential energy per particle

    NARCIS (Netherlands)

    Ventevogel, W.J.; Nijboer, B.R.A.

    1979-01-01

    In continuation of previous work we extend the class of two-body potentials, either repulsive or of generalized Lennard-Jones type, for which it can be proved that among all configurations of an infinite one-dimensional system of interacting particles (with fixed density in the case of repulsive int

  4. Static configurations and evolution of higher dimensional brane-dilaton black hole system

    Science.gov (United States)

    Nakonieczna, Anna; Nakonieczny, Łukasz; Moderski, Rafaƚ; Rogatko, Marek

    2016-12-01

    Static configurations and a dynamical evolution of the system composed of a higher-dimensional spherically symmetric dilaton black hole and the Dirac-Goto-Nambu brane were investigated. The studies were conducted for three values of the dilaton coupling constant, describing the uncoupled case, the low-energy limit of the string theory and dimensionally reduced Klein-Kaluza theories. When the black hole is nonextremal, two types of static configurations are observed, a brane which intersects the black hole horizon and a brane not having any common points with the accompanying black hole. As the number of spacetime dimensions increases, the brane bend in the vicinity of the black hole disappears closer to its horizon. Dynamical evolution of the system results in an expulsion of the black hole from the brane. It proceeds faster for bigger values of the bulk spacetime dimension and thicker branes. The value of the dilatonic coupling constant does not influence neither the static configurations nor the dynamical behavior of the examined nonextremal system. In the extremal dilaton black hole case one obtains expulsion of the brane which is independent on the spacetime dimensionality and the value of the coupling constant. Dynamical studies of the configurations in the extremal case reveal that the course of evolution of the system is similar to the nonextremal one, except for a slightly earlier expulsion of the black hole from the brane.

  5. Multi-reactor power system configurations for multimegawatt nuclear electric propulsion

    Science.gov (United States)

    George, Jeffrey A.

    1991-01-01

    A modular, multi-reactor power system and vehicle configuration for piloted nuclear electric propulsion (NEP) missions to Mars is presented. Such a design could provide enhanced system and mission reliability, allowing a comfortable safety margin for early manned flights, and would allow a range of piloted and cargo missions to be performed with a single power system design. Early use of common power modules for cargo missions would also provide progressive flight experience and validation of standardized systems for use in later piloted applications. System and mission analysis are presented to compare single and multi-reactor configurations for piloted Mars missions. A conceptual design for the Hydra modular multi-reactor NEP vehicle is presented.

  6. Microsoft System Center Configuration Manager 2012, migraatio versiosta 2007 : Case: TTY

    OpenAIRE

    Louhi, Jenni

    2013-01-01

    Kun tietokoneita on paljon, ohjelmien asennus ja päivitys kone kerrallaan ei ole kustannustehokasta. Microsoft System Center Configuration Manager on tuote, jolla automatisoitujen ohjelma-asennusten ajaminen voidaan hoitaa keskitetysti useille koneille yhtä aikaa. Tampereen teknillisen yliopiston Tietohallinnon tukipalvelut -yksikössä on käytössä Configuration Manager 2007, jota käytetään sekä käyttöjärjestelmä- että ohjelmistoasennuksiin. Tavoite on siirtää toiminnot uuteen 2012-ympärist...

  7. Analysis and Evaluation of Error-Proof Systems for Configuration Data Management in Railway Signalling

    Science.gov (United States)

    Shimazoe, Toshiyuki; Ishikawa, Hideto; Takei, Tsuyoshi; Tanaka, Kenji

    Recent types of train protection systems such as ATC require the large amounts of low-level configuration data compared to conventional types of them. Hence management of the configuration data is becoming more important than before. Because of this, the authors developed an error-proof system focusing on human operations in the configuration data management. This error-proof system has already been introduced to the Tokaido Shinkansen ATC data management system. However, as effectiveness of the system has not been presented objectively, its full perspective is not clear. To clarify the effectiveness, this paper analyses error-proofing cases introduced to the system, using the concept of QFD and the error-proofing principles. From this analysis, the following methods of evaluation for error-proof systems are proposed: metrics to review the rationality of required qualities are provided by arranging the required qualities according to hazard levels and work phases; metrics to evaluate error-proof systems are provided to improve their reliability effectively by mapping the error-proofing principles onto the error-proofing cases which are applied according to the required qualities and the corresponding hazard levels. In addition, these objectively-analysed error-proofing cases are available to be used as error-proofing-cases database or guidelines for safer HMI design especially for data management.

  8. Tank waste remediation system FSAR hazard identification/facility configuration verification report

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza, D.P., Westinghouse Hanford

    1996-05-01

    This document provides the results of the Tank Waste Remediation System Final Safety Analysis Report (TWRS FSAR) hazards identification/facility configuration activities undertaken from the period of March 7, 1996 to May 31, 1996. The purpose of this activity was to provide an independent overview of the TWRS facility specific hazards and configurations that were used in support of the TWRS FSAR hazards and accident analysis development. It was based on a review of existing published documentation and field inspections. The objective of the verification effort was to provide a `snap shot` in time of the existing TWRS facility hazards and configurations and will be used to support hazards and accident analysis activities.

  9. A "configurational-entropy-loss" law for the non-Arrhenius relaxation in disordered systems

    CERN Document Server

    Wang, Yi-zhen; Zhang, Jin-xiu

    2012-01-01

    Based on Nowick's self-induced ordering theory, we develop a new configurational-entropy relation to describe the non-Arrhenius temperature(T)-dependent relaxation in disordered systems. Both the configurational-entropy loss and the coupling interaction among relaxing units (RUs) are explicitly introduced in this relation; thus, it offers a novel connection between kinetics and thermodynamics that is different from the Adam-Gibbs (A-G) entropy relation, and it generalizes several well-known currently used relations. The present relation can provide direct and more accurate estimates of (i) the intrinsic activation enthalpy, (ii) the T-evolvement of the systematic configurational entropy loss and (iii) the self-induced ordering temperature Tc, which characterizes the coupling interaction among RUs. Application of the theory to experimental relaxation-time data for typical organic liquids demonstrates its validity.

  10. A Configuration System for Supportive Purposes in the Middle of a Product Lifecycle

    DEFF Research Database (Denmark)

    Christensen, Tim Teglgaard; Hvam, Lars

    2006-01-01

    This paper presents a new way of using configuration systems. Traditionally, these systems have been use for decision support for sales. The aim is now to support "Middle-Of-Lifecycle" (MOL) processes, which means that the decision support system is targeted for the customers and the manufacturer...... (field services, technical support and after sales). This is especially interesting, as manufacturing companies are increasingly focusing their operations on service operations. The background for this idea is that companies often experience a lack of information between the initial sale...... and the following service operations. For instance, the sales info regarding a product is often obsolete due to changes in the product setup since installation/implementation, and considerable amounts of time are wasted on inefficient updates. To support the daily blusiness we suggest using configuration systems...

  11. Photovoltaic power converter system with a controller configured to actively compensate load harmonics

    Science.gov (United States)

    de Rooij, Michael Andrew; Steigerwald, Robert Louis; Delgado, Eladio Clemente

    2008-12-16

    Photovoltaic power converter system including a controller configured to reduce load harmonics is provided. The system comprises a photovoltaic array and an inverter electrically coupled to the array to generate an output current for energizing a load connected to the inverter and to a mains grid supply voltage. The system further comprises a controller including a first circuit coupled to receive a load current to measure a harmonic current in the load current. The controller includes a second circuit to generate a fundamental reference drawn by the load. The controller further includes a third circuit for combining the measured harmonic current and the fundamental reference to generate a command output signal for generating the output current for energizing the load connected to the inverter. The photovoltaic system may be configured to compensate harmonic currents that may be drawn by the load.

  12. A Common Software-Configuration Management System for CERN SPS and LEP Accelerators and Technical Services

    CERN Document Server

    Hatziangeli, Eugenia; Bragg, A E; Ninin, P; Patino, J; Sobczak, H

    2000-01-01

    Software-configuration management activities are crucial to ensure the integrity of current operational software and the quality of new software either being developed at CERN or outsourced. The functionality of the present management system became insufficient with large maintenance overheads. In order to improve our situation, a new software-configuration management system has been set up. It is based on Razor R, a commercial tool, which supports the management of file versions and operational software releases, along with integrated problem-reporting capabilities. In addition to the basic tool functionality, automated procedures were custom-made for the installation and distribution of operational software. The system ensures that, at all times, the status and location of all deliverable versions are known, the state of shared objects is carefully controlled and unauthorized changes prevented. This paper outlines the reasons for selecting the chosen tool, the implementation of the system and the final goal...

  13. Comparison of methods to evaluate the fungal biomass in heating, ventilation, and air-conditioning (HVAC) dust.

    Science.gov (United States)

    Biyeyeme Bi Mve, Marie-Jeanne; Cloutier, Yves; Lacombe, Nancy; Lavoie, Jacques; Debia, Maximilien; Marchand, Geneviève

    2016-12-01

    Heating, ventilation, and air-conditioning (HVAC) systems contain dust that can be contaminated with fungal spores (molds), which may have harmful effects on the respiratory health of the occupants of a building. HVAC cleaning is often based on visual inspection of the quantity of dust, without taking the mold content into account. The purpose of this study is to propose a method to estimate fungal contamination of dust in HVAC systems. Comparisons of different analytical methods were carried out on dust deposited in a controlled-atmosphere exposure chamber. Sixty samples were analyzed using four methods: culture, direct microscopic spore count (DMSC), β-N-acetylhexosaminidase (NAHA) dosing and qPCR. For each method, the limit of detection, replicability, and repeatability were assessed. The Pearson correlation coefficients between the methods were also evaluated. Depending on the analytical method, mean spore concentrations per 100 cm(2) of dust ranged from 10,000 to 682,000. Limits of detection varied from 120 to 217,000 spores/100 cm(2). Replicability and repeatability were between 1 and 15%. Pearson correlation coefficients varied from -0.217 to 0.83. The 18S qPCR showed the best sensitivity and precision, as well as the best correlation with the culture method. PCR targets only molds, and a total count of fungal DNA is obtained. Among the methods, mold DNA amplification by qPCR is the method suggested for estimating the fungal content found in dust of HVAC systems.

  14. Analysis of visual representation techniques for product configuration systems in industrial companies

    DEFF Research Database (Denmark)

    Shafiee, Sara; Kristjansdottir, Katrin; Hvam, Lars;

    2016-01-01

    In recent years, there has been an increasing demand for customized products. Product configuration systems (PCS) are introduced as one of the most successful systems of artificial intelligent for providing customized products. One of the main challenges in PCSs projects are described in relation...... in PCSs projects will result in improved quality of maintenance and development support for the knowledge base and improved quality of the communication with domain experts....

  15. Integrated Control of air distribution system noise-- A nuclear power plant control room HVAC system%空气输配系统噪声综合控制研究--某核电厂主控室暖通空调系统

    Institute of Scientific and Technical Information of China (English)

    刘海成

    2016-01-01

    China has built nuclear power plant main control room noise value agreed to 56dB (A) or so, after the noise control noise is 53dB (A) or so. However, according to relevant national standards, environmental noise limits for new projects main control room to achieve 45dB (A). Accordingly, the monitoring of operating nuclear power plants in the main control room noise, room sound field simulation and identify sound sources, found that: air HVAC system noise of the air distribution system to produce secondary duct itself radiated noise excitation is sound and solid the main source of indoor master acoustic environment. Studies have shown that: the main factors vent excessive noise muffler system design is unreasonable, the system calculation inaccurate flow noise, noise reduction equipment and system performance is not reasonable match and the lack of relevant engineering experience. In this paper, the problems identified, the system describes the different mechanisms produce noise with different noise reduction measures should be analyzed wind pipe itself radiated noise excitation and solid sound excessivecountermeasures, and from the HVAC system controls air distribution system starting noise, it made a similar noise reduction reference integrated HVAC systems solutions.%我国已建成的核电厂主控室内噪声值约定为56dB(A)左右,经噪声控制后噪声值为53dB(A)左右。但是根据有关国家标准的要求,新建项目主控室的环境噪声限值要达到45dB (A)。据此,监测在运行核电厂主控室内噪声,识别室内声场模拟及声源,发现:暖通空调系统之空气输配系统产生的风口噪声、风管本身辐射的二次激发噪声及固体声是主控室内声环境的最主要声源。研究表明:风口噪声超标主要因素有系统消声设计不合理,系统气流再生噪声计算不精确,消声设备性能与系统未合理匹配及缺乏相关工程经验等。本文针对问题

  16. Anisotropy in Thermo-Optic Coefficient of Different Polymer Systems by Attenuated Total Reflection Configuration

    Institute of Scientific and Technical Information of China (English)

    LI Xiang; CAO Zhuang-Qi; SHEN Qi-Shun; MENG Qing-Hua; HUANG De-Ying; GUO Kun-Peng; QIU Ling; SHEN Yu-Quan

    2006-01-01

    @@ Thermo-optic coefficient dn/dT as well as volume expansion coefficients β of different polymer systems are measured for both TE and TM polarizations in an attenuated total reflection (ATR) configuration. Experimental results indicate that cross-linked polymer systems exhibit the thermal expansion coefficients smaller than those of the original side-chain systems. Moreover, the anisotropies in thermo-optic coefficients of the polymer systems with small birefringence exhibit linear relationship with the anisotropies in volume expansion coefficients, but the polymer systems with larger birefringence exhibit more complicated relationship.

  17. Thermoelectric Generator Power Converter System Configurations: A Review

    DEFF Research Database (Denmark)

    Man, Elena Anamaria; Schaltz, Erik; Rosendahl, Lasse

    2013-01-01

    tracking (MPPT) technique is widely used for TEG systems. The aim of this paper is to create a survey over the existing state-of-the-art TEG system configurations for TE energy harvesting. Depending on the application specifications, a suitable TEG system topology can be designed with the purpose......In a Thermoelectric Generator (TEG) system, the Thermoelectric (TE) modules can be connected in series, parallel or a combination of both. Independent of the module connection, the power production of the TEG changes with the temperature gradient applied at its input. In consequence, the system...

  18. A multi-perspective approach for the design of Product Configuration Systems - an evaluation of industry applications

    DEFF Research Database (Denmark)

    Hvam, Lars

    2004-01-01

    This article presents a suggested procedure for modelling and implementation of product configuration systems. The procedure has been applied in several industrial companies. The procedure comprises: • Analysis of the business processes to be supported by a product configuration system. Furthermore......, a de-marcation and definition of the configuration system to be designed. • Analysis and modelling of the part of the company’s product assortment which is to be included in the con-figuration system. • Selection of configuration software and programming of the configuration system. • Implementation....... The procedure or certain parts of the procedure have currently been tested and further developed in cooperation with a number of industrial companies including F.L.Smidth, American Power Conversion (APC), Aalborg industries, NEG-Micon, GEA-Niro and IBM-SMS. This paper presents the experiences gained from 4...

  19. Sensor Configuration Selection for Discrete-Event Systems under Unreliable Observations

    Energy Technology Data Exchange (ETDEWEB)

    Wen-Chiao Lin; Tae-Sic Yoo; Humberto E. Garcia

    2010-08-01

    Algorithms for counting the occurrences of special events in the framework of partially-observed discrete event dynamical systems (DEDS) were developed in previous work. Their performances typically become better as the sensors providing the observations become more costly or increase in number. This paper addresses the problem of finding a sensor configuration that achieves an optimal balance between cost and the performance of the special event counting algorithm, while satisfying given observability requirements and constraints. Since this problem is generally computational hard in the framework considered, a sensor optimization algorithm is developed using two greedy heuristics, one myopic and the other based on projected performances of candidate sensors. The two heuristics are sequentially executed in order to find best sensor configurations. The developed algorithm is then applied to a sensor optimization problem for a multiunit- operation system. Results show that improved sensor configurations can be found that may significantly reduce the sensor configuration cost but still yield acceptable performance for counting the occurrences of special events.

  20. A Systems Engineering Analysis of Three-Point and Four-Point Wind Turbine Drivetrain Configurations

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Yi; Parsons, Tyler; Dykes, Katherine; King, Ryan N.

    2017-03-01

    This study compares the impact of drivetrain configuration on the mass and capital cost of a series of wind turbines ranging from 1.5 MW to 5.0 MW power ratings for both land-based and offshore applications. The analysis is performed with a new physics-based drivetrain analysis and sizing tool, Drive Systems Engineering (DriveSE), which is part of the Wind-Plant Integrated System Design & Engineering Model. DriveSE uses physics-based relationships to size all major drivetrain components according to given rotor loads simulated based on International Electrotechnical Commission design load cases. The model's sensitivity to input loads that contain a high degree of variability was analyzed. Aeroelastic simulations are used to calculate the rotor forces and moments imposed on the drivetrain for each turbine design. DriveSE is then used to size all of the major drivetrain components for each turbine for both three-point and four-point configurations. The simulation results quantify the trade-offs in mass and component costs for the different configurations. On average, a 16.7% decrease in total nacelle mass can be achieved when using a three-point drivetrain configuration, resulting in a 3.5% reduction in turbine capital cost. This analysis is driven by extreme loads and does not consider fatigue. Thus, the effects of configuration choices on reliability and serviceability are not captured. However, a first order estimate of the sizing, dimensioning and costing of major drivetrain components are made which can be used in larger system studies which consider trade-offs between subsystems such as the rotor, drivetrain and tower.

  1. Configuration of Risk Monitor System by PLant Defense-In.Depth Monitor and Relability Monitor

    DEFF Research Database (Denmark)

    Yoshikawa, Hidekazu; Lind, Morten; Yang, Ming;

    2012-01-01

    A new method of risk monitor system of a nuclear power plant has been proposed from the aspect by what degree of safety functions incorporated in the plant system is maintained by multiple barriers of defense-in-depth (DiD). Wherein, the central idea is plant DiD risk monitor and reliability...... monitor derived from the four aspects of (i) design principle of nuclear safety to realize DiD concept, (ii) definition of risk and risk to be monitored, (iii) severe accident phenomena as major risk, (iv) scheme of risk ranking, and (v) dynamic risk display. In this paper, the overall frame...... of the proposed frame on risk monitor system is summarized and the detailed discussion is made on the definitions of major terminologies of risk, risk ranking, anatomy of fault occurrence, two-layer configuration of risk monitor, how to configure individual elements of plant DiD risk monitor and its example...

  2. Investigation of thermal protection system by forward-facing cavity and opposing jet combinatorial configuration

    Institute of Scientific and Technical Information of China (English)

    Lu Haibo; Liu Weiqiang

    2013-01-01

    This paper focuses on the usage of the forward-facing cavity and opposing jet combinatorial configuration as the thermal protection system (TPS) for hypersonic vehicles.A hemispherecone nose-tip with the combinatorial configuration is investigated numerically in hypersonic free stream.Some numerical results are validated by experiments.The flow field parameters,aerodynamic force and surface heat flux distribution are obtained.The influence of the opposing jet stagnation pressure on cooling efficiency of the combinatorial TPS is discussed.The detailed numerical results show that the aerodynamic heating is reduced remarkably by the combinatorial system.The recirculation region plays a pivotal role for the reduction of heat flux.The larger the stagnation pressure of opposing jet is,the more the heating reduction is.This kind of combinatorial system is suitable to be the TPS for the high-speed vehicles which need long-range and long time flight.

  3. A Common Software Configuration Management System for CERN SPS and LEP Accelerators and Technical Services

    CERN Document Server

    Hatziangeli, Eugenia; Bragg, A E; Ninin, P; Patino, J; Sobczak, H

    1999-01-01

    Software configuration management activities are crucial to assure the integrity of current operational and the quality of new software either being developed at CERN or outsourced. The functionality of the present management system became insufficient with large maintenance overheads. In order to improve our situation, a new software configuration management system has been set up. It is based on Razor, a commercial tool, which supports the management of file versions and operational software releases, along with integrated problem reporting capabilities. In addition to the basic tool functionality, automated procedures were custom made, for the installation and distribution of operational software. Policies were developed and applied over the software development life cycle to provide visibility and control. The system ensures that, at all times, the status and location of all deliverable versions are known, the state of shared objects is carefully controlled and unauthorised changes prevented. It provides ...

  4. Hybrid Configuration of Darrieus and Savonius Rotors for Stand-alone Power Systems

    Science.gov (United States)

    Wakui, Tetsuya; Tanzawa, Yoshiaki; Hashizume, Takumi; Nagao, Toshio

    The suitable hybrid configuration of Darrieus lift-type and Savonius drag-type rotors for stand-alone wind turbine-generator systems is discussed using our dynamic simulation model. Two types of hybrid configurations are taken up: Type-A installs the Savonius rotor inside the Darrieus rotor and Type-B installs the Savonius rotor outside the Darrieus rotor. The computed results of the output characteristics and the dynamic behaviors of the system operated at the maximum power coefficient points show that Type-A, which has fine operating behavior to wind speed changes and can be compactly designed because of a shorter rotational shaft, is an effective way for self-controlled stand-alone small-scale systems.

  5. Software Configuration Management Plan for the K West Basin Integrated Water Treatment System (IWTS) Project A.9

    Energy Technology Data Exchange (ETDEWEB)

    GREEN, J.W.

    2000-05-01

    This document provides a configuration control plan for the software associated with the operation and control of the Integrated Water Treatment System (IWTS). It establishes requirements for ensuring configuration item identification, configuration control, configuration status accounting, defect reporting and resolution of computer software. It is written to comply with HNF-SD-SNF-CM-001, Spent Nuclear Fuel Configuration Management Plan (Forehand 1998) and HNF-PRO-309 Computer Software Quality Assurance Requirements, and applicable sections of administrative procedure CM-6-037-00, SNF Project Process Automation Software and Equipment.

  6. Development on systems configuration in ITER Tokamak Complex and Auxiliary Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Kuehn, Ingo, E-mail: ingo.kuehn@iter.org [ITER Organization, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Kotamaki, Miikka [ITER Organization, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Schmieder, Laurent [Fusion for Energy (F4E), CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Cordier, Jean-Jacques; Chiocchio, Stefano; Carafa, Leontin; Klingsmith, James; Patisson, Laurent; Rigoni, Giuliano [ITER Organization, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Tsedri, Thibault [AREVA CNIM KAH System Engineering Support, CS 50497, 13593 Aix en Provence Cedex 3 (France)

    2011-10-15

    The ITER site consists of almost 30 buildings to service the Tokamak machine which is located in the centre of the Tokamak Complex facility with the Tokamak-, Diagnostic- and Tritium building. The design of a large part of the ITER plant systems will be executed by the ITER Domestic Agencies or their industrial suppliers under functional specifications provided by the ITER Organization. At the same time, the detailed design of the building is carried out by the European Domestic Agency 'Fusion for Energy' (F4E). In order to allow an efficient identification of the ITER configuration as well as to manage the concurrent engineering activities and to simplify the identification and assessment of changes, the design of each ITER plant systems is described in the so-called Configuration Management Models (CMM). These are light CATIA 3D models that define the required space envelope and the physical interfaces in-between the systems and the buildings. The paper describes the procedure adopted for the control of the baseline configuration of the Tokamak Complex facility and Auxiliary Buildings with their associated plant systems and illustrates the current status as well as recent developments in the different systems.

  7. A configurable component-based software system for magnetic field measurements

    Energy Technology Data Exchange (ETDEWEB)

    Nogiec, J.M.; DiMarco, J.; Kotelnikov, S.; Trombly-Freytag, K.; Walbridge, D.; Tartaglia, M.; /Fermilab

    2005-09-01

    A new software system to test accelerator magnets has been developed at Fermilab. The magnetic measurement technique involved employs a single stretched wire to measure alignment parameters and magnetic field strength. The software for the system is built on top of a flexible component-based framework, which allows for easy reconfiguration and runtime modification. Various user interface, data acquisition, analysis, and data persistence components can be configured to form different measurement systems that are tailored to specific requirements (e.g., involving magnet type or test stand). The system can also be configured with various measurement sequences or tests, each of them controlled by a dedicated script. It is capable of working interactively as well as executing a preselected sequence of tests. Each test can be parameterized to fit the specific magnet type or test stand requirements. The system has been designed with portability in mind and is capable of working on various platforms, such as Linux, Solaris, and Windows. It can be configured to use a local data acquisition subsystem or a remote data acquisition computer, such as a VME processor running VxWorks. All hardware-oriented components have been developed with a simulation option that allows for running and testing measurements in the absence of data acquisition hardware.

  8. Software configuration management plan, 241-AY and 241-AZ tank farm MICON automation system

    Energy Technology Data Exchange (ETDEWEB)

    Hill, L.F.

    1997-10-30

    This document establishes a Computer Software Configuration Management Plan (CSCM) for controlling software for the MICON Distributed Control System (DCS) located at the 241-AY and 241-AZ Aging Waste Tank Farm facilities in the 200 East Area. The MICON DCS software controls and monitors the instrumentation and equipment associated with plant systems and processes. A CSCM identifies and defines the configuration items in a system (section 3.1), controls the release and change of these items throughout the system life cycle (section 3.2), records and reports the status of configuration items and change requests (section 3.3), and verifies the completeness and correctness of the items (section 3.4). All software development before initial release, or before software is baselined, is considered developmental. This plan does not apply to developmental software. This plan applies to software that has been baselined and released. The MICON software will monitor and control the related instrumentation and equipment of the 241-AY and 241-AZ Tank Farm ventilation systems. Eventually, this software may also assume the monitoring and control of the tank sludge washing equipment and other systems as they are brought on line. This plan applies to the System Cognizant Manager and MICON Cognizant Engineer (who is also referred to herein as the system administrator) responsible for the software/hardware and administration of the MICON system. This document also applies to any other organizations within Tank Farms which are currently active on the system including system cognizant engineers, nuclear operators, technicians, and control room supervisors.

  9. An open and configurable embedded system for EMG pattern recognition implementation for artificial arms.

    Science.gov (United States)

    Jun Liu; Fan Zhang; Huang, He Helen

    2014-01-01

    Pattern recognition (PR) based on electromyographic (EMG) signals has been developed for multifunctional artificial arms for decades. However, assessment of EMG PR control for daily prosthesis use is still limited. One of the major barriers is the lack of a portable and configurable embedded system to implement the EMG PR control. This paper aimed to design an open and configurable embedded system for EMG PR implementation so that researchers can easily modify and optimize the control algorithms upon our designed platform and test the EMG PR control outside of the lab environments. The open platform was built on an open source embedded Linux Operating System running a high-performance Gumstix board. Both the hardware and software system framework were openly designed. The system was highly flexible in terms of number of inputs/outputs and calibration interfaces used. Such flexibility enabled easy integration of our embedded system with different types of commercialized or prototypic artificial arms. Thus far, our system was portable for take-home use. Additionally, compared with previously reported embedded systems for EMG PR implementation, our system demonstrated improved processing efficiency and high system precision. Our long-term goals are (1) to develop a wearable and practical EMG PR-based control for multifunctional artificial arms, and (2) to quantify the benefits of EMG PR-based control over conventional myoelectric prosthesis control in a home setting.

  10. Configuration Analysis of the ERS Points in Large-Volume Metrology System.

    Science.gov (United States)

    Jin, Zhangjun; Yu, Cijun; Li, Jiangxiong; Ke, Yinglin

    2015-09-22

    In aircraft assembly, multiple laser trackers are used simultaneously to measure large-scale aircraft components. To combine the independent measurements, the transformation matrices between the laser trackers' coordinate systems and the assembly coordinate system are calculated, by measuring the enhanced referring system (ERS) points. This article aims to understand the influence of the configuration of the ERS points that affect the transformation matrix errors, and then optimize the deployment of the ERS points to reduce the transformation matrix errors. To optimize the deployment of the ERS points, an explicit model is derived to estimate the transformation matrix errors. The estimation model is verified by the experiment implemented in the factory floor. Based on the proposed model, a group of sensitivity coefficients are derived to evaluate the quality of the configuration of the ERS points, and then several typical configurations of the ERS points are analyzed in detail with the sensitivity coefficients. Finally general guidance is established to instruct the deployment of the ERS points in the aspects of the layout, the volume size and the number of the ERS points, as well as the position and orientation of the assembly coordinate system.

  11. Development and implementation strategy for the of product configuration systems in engineer-to-order companies

    DEFF Research Database (Denmark)

    Kristjansdottir, Katrin; Shafiee, Sara; Hvam, Lars

    2016-01-01

    This paper will address how to develop a strategy when developing and implementing product configuration systems (PCSs) in engineer-to-order (ETO) companies. PCSs are often gradually implemented especially where there are complex products and processes in order to break down the overall project...... and reduce risk. This highlights the importance of having an overall strategy to guide the long-term development and implementation of PCSs In this paper, guideline for making the strategy are provided and supplemented with examples based on a case study. The guideline includes the main objectives...... for the development and implementation process, PCSs to be used to support the sales and /or the engineering processes, more uniform IT support for making product configurations, combining output from different PCSs and finally integrations that includes both internal and external IT systems. Based...

  12. Product configuration system and its impact on product’s life cycle complexity

    DEFF Research Database (Denmark)

    Myrodia, Anna; Kristjansdottir, Katrin; Shafiee, Sara

    2016-01-01

    The purpose of this paper is to identify areas throughout a product's lifecycle processes where complexity can be reduced by implementing a product configuration system (PCS). As discussed in the literature, several benefits are realized by using a PCS in terms of product and process standardizat...... for the company in several life cycle processes.......The purpose of this paper is to identify areas throughout a product's lifecycle processes where complexity can be reduced by implementing a product configuration system (PCS). As discussed in the literature, several benefits are realized by using a PCS in terms of product and process...... standardization. This also leads to control and reduce of complexity both in products and processes. To this end, this research attempts to quantify and assess these benefits and is supported by empirical evidence. A case study of an engineering company is used and the results indicate significant improvements...

  13. Impact of the utilization of a product configuration system on product’s life cycle complexity

    DEFF Research Database (Denmark)

    Myrodia, Anna; Kristjansdottir, Katrin; Shafiee, Sara

    The purpose of this paper is to identify areas throughout a product’s lifecycle processes where complexity can be reduced by implementing a product configuration system (PCS). As discussed in the literature, several benefits are realized by using a PCS in terms of product and process standardizat...... for the company in several life cycle processes.......The purpose of this paper is to identify areas throughout a product’s lifecycle processes where complexity can be reduced by implementing a product configuration system (PCS). As discussed in the literature, several benefits are realized by using a PCS in terms of product and process...... standardization. This also leads to control and reduce of complexity both in products and processes. To this end, this research attempts to quantify and assess these benefits and is supported by empirical evidence. A case study of an engineering company is used and the results indicate significant improvements...

  14. Interaction of systems integration, assembly, disassembly and maintenance in developing the INTOR-NET mechanical configuration

    Energy Technology Data Exchange (ETDEWEB)

    Farfaletti-Casali, F.; Booker, D.; Buzzi, U.; Casini, G.; Gritzmann, P. (Commission of the European Communities, Ispra (Italy). Joint Research Centre); Cardella, A. (Nucleare Italiana Reattori Avanzati S.p.A. (NIRA), Genoa)

    1984-04-01

    The driving concepts of systems integration, based on assembly, disassembly and maintenance requirements which define the mechanical configuration of INTOR (a world-wide conceptual study of an experimental Tokamak-type power fusion reactor of the next generation), are presented as the starting point for the studies carried out in this field at JRC-Ispra. Complementary new developments recently incorporated into the European version of INTOR, referred to as INTOR-NET, are described in detail and compared with the original concepts. The aim in INTOR-NET has been to reduce the physical size of the reactor while retaining similar plasma parameters. New systems integration and mechanical configuration concepts are introduced which can be used in future investigations for the NET design as alterantive options. Further reductions in reactor and/or improvements in the maintenance approach appear possible.

  15. Quantification of Benefits and Cost from Applying a Product Configuration System

    DEFF Research Database (Denmark)

    Kristjansdottir, Katrin; Shafiee, Sara; Hvam, Lars

    This article aims at analyzing the long-term benefits and the cost from developing, implementing and maintaining product configuration systems (PCSs). The results presented indicate that over 5 years period a case company has achieved significant savings as a result to reduced workload of generat......This article aims at analyzing the long-term benefits and the cost from developing, implementing and maintaining product configuration systems (PCSs). The results presented indicate that over 5 years period a case company has achieved significant savings as a result to reduced workload...... of generating the products’ specifications. In addition the lead-time for generating products’ specifications has been reduced and indications of improved quality of the products’ specifications and additional sales are identified. The research verifies the benefits described in the current literature...... and contributes by linking the benefits to the direct cost savings companies can expect from utilizing PCSs....

  16. xpected and Realized Costs and Benefits when Implementing Product Configuration Systems

    DEFF Research Database (Denmark)

    Edwards, Kasper; Riis, Jesper

    2004-01-01

    This paper reports preliminary findings from a study of a number of Danish firms, which have or are in the process of implementing product configuration systems. 20 firms were selected and 15 responded positively and as of writing 10 interviews have been completed. Data are presented which...... illustrate the relative costs and benefits in each firm. It is observed that expected and realised benefits are consistent: 1) Improved quality in specifications, 2) Using less resources, and 3) Lower turnaround time....

  17. The documentation of product configuration systems: A framework and an IT solution

    DEFF Research Database (Denmark)

    Shafiee, Sara; Hvam, Lars; Haug, Anders

    2017-01-01

    When designing and maintaining a product configuration system (PCS), complete and up-to-date documentation of the system is needed in the form of a product model that outlines the structures, attributes, and constraints of the PCS. Furthermore, up-to-date documentation for the PCS is crucial...... for maintenance, further development, system quality and communication with domain experts. Product models are the main communication and documentation tools used in PCS projects. Recent studies have shown that up-to-date documentation for the PCS is often lacking due to the significant amount of work required...

  18. Optimal configuration of power generating systems in isolated island with renewable energy

    Energy Technology Data Exchange (ETDEWEB)

    Senjyu, Tomonobu; Hayashi, Daisuke; Yona, Atsushi; Urasaki, Naomitsu [Faculty of Engineering, University of the Ryukyus, 1 Senbaru, Nishihara-cho, Nakagami, Okinawa 903-0213 (Japan); Funabashi, Toshihisa [Meidensha Corporation, 36-2 Nihonbashi Hakozakicho, Chuo-ku, Tokyo 103-8515 (Japan)

    2007-09-15

    In isolated islands, usually diesel generators supply electric power. However, there are problems, e.g., a lack of fossil fuel, environmental pollution etc. So, isolated island, e.g. Miyako island, installs renewable energy power production plants. However, renewable energy power production plants are very costly. This paper presents an optimal configuration of power system in isolated island installing renewable energy power production plants. The generating system consists of diesel generators, wind turbine generators, PV system and batteries. Using the proposed method, operation cost can be reduced about 10% in comparison with diesel generators only from simulation results. (author)

  19. A configurable electronics system for the ESS-Bilbao beam position monitors

    Energy Technology Data Exchange (ETDEWEB)

    Muguira, L., E-mail: lmuguira@essbilbao.org [ESS-Bilbao, Edificio Rectorado, Vivero de Empresas, 48940 Leioa (Bizkaia) (Spain); Belver, D. [ESS-Bilbao, Edificio Rectorado, Vivero de Empresas, 48940 Leioa (Bizkaia) (Spain); Etxebarria, V. [University of Basque Country (UPV/EHU), Department of Electricity and Electronics, Science and Technology Faculty, 48940 Leioa (Bizkaia) (Spain); Varnasseri, S.; Arredondo, I.; Campo, M. del; Echevarria, P.; Garmendia, N.; Feuchtwanger, J. [ESS-Bilbao, Edificio Rectorado, Vivero de Empresas, 48940 Leioa (Bizkaia) (Spain); Jugo, J.; Portilla, J. [University of Basque Country (UPV/EHU), Department of Electricity and Electronics, Science and Technology Faculty, 48940 Leioa (Bizkaia) (Spain)

    2013-09-01

    A versatile and configurable system has been developed in order to monitorize the beam position and to meet all the requirements of the future ESS-Bilbao Linac. At the same time the design has been conceived to be open and configurable so that it could eventually be used in different kinds of accelerators, independent of the charged particle, with minimal change. The design of the Beam Position Monitors (BPMs) system includes a test bench both for button-type pick-ups (PU) and striplines (SL), the electronic units and the control system. The electronic units consist of two main parts. The first part is an Analog Front-End (AFE) unit where the RF signals are filtered, conditioned and converted to base-band. The second part is a Digital Front-End (DFE) unit which is based on an FPGA board where the base-band signals are sampled in order to calculate the beam position, the amplitude and the phase. To manage the system a Multipurpose Controller (MC) developed at ESSB has been used. It includes the FPGA management, the EPICS integration and Archiver Instances. A description of the system and a comparison between the performance of both PU and SL BPM designs measured with this electronics system are fully described and discussed. -- Author-Highlights: • A versatile and configurable BPM system for the ESS-Bilbao Linac has been designed. • The design works for PU and SL detectors, both in continuous and pulsed wave modes. • Several tests at simulated beamlines at 352 MHz and 175 MHz have been performed. • The BPM system has been integrated in EPICS and Archiver.

  20. A Comparative case study of remote area power supply systems using photovoltaic-battery vs thermoelectric-battery configuration

    NARCIS (Netherlands)

    Tan, Lippong; Date, Abhijit; Zhang, Bingjie; Singh, Baljit; Ganguly, Sayantan

    The paper presents a comparative study of two types of remote area power supply (RAPS) systems, which are the existing photovoltaic-based (PV) configuration and the proposed thermoelectric-based (TE) configuration. Both RAPS systems are solar-based power generators and sized according to Melbourne

  1. A PC program to optimize system configuration for desired reliability at minimum cost

    Science.gov (United States)

    Hills, Steven W.; Siahpush, Ali S.

    1994-01-01

    High reliability is desired in all engineered systems. One way to improve system reliability is to use redundant components. When redundant components are used, the problem becomes one of allocating them to achieve the best reliability without exceeding other design constraints such as cost, weight, or volume. Systems with few components can be optimized by simply examining every possible combination but the number of combinations for most systems is prohibitive. A computerized iteration of the process is possible but anything short of a super computer requires too much time to be practical. Many researchers have derived mathematical formulations for calculating the optimum configuration directly. However, most of the derivations are based on continuous functions whereas the real system is composed of discrete entities. Therefore, these techniques are approximations of the true optimum solution. This paper describes a computer program that will determine the optimum configuration of a system of multiple redundancy of both standard and optional components. The algorithm is a pair-wise comparative progression technique which can derive the true optimum by calculating only a small fraction of the total number of combinations. A designer can quickly analyze a system with this program on a personal computer.

  2. Energization of Long HVAC Cables in Parallel - Analysis and Estimation Formulas

    DEFF Research Database (Denmark)

    Silva, Filipe Faria Da; Bak, Claus Leth

    2012-01-01

    The installation of long HVAC cables has recently become more common and it tends to increase during the next years. Consequently, the energization of long HVAC cables in parallel is also a more common condition. The energization of HVAC cables in parallel resembles the en-ergization of capacitor...

  3. 10 CFR 431.402 - Preemption of State regulations for commercial HVAC & WH products.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Preemption of State regulations for commercial HVAC & WH... regulations for commercial HVAC & WH products. Beginning on the effective date of such standard, an energy conservation standard set forth in this Part for a commercial HVAC & WH product supersedes any State or...

  4. Introduction to Heating, Ventilation and Air Conditioning (HVAC). Instructor Edition. Introduction to Construction Series.

    Science.gov (United States)

    Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This instructor's guide contains the materials required to teach a competency-based introductory course in heating, ventilating, and air conditioning (HVAC) to students who have chosen to explore careers in construction. It contains three units: HVAC materials, HVAC tools, and applied skills. Each instructional unit includes some or all of the…

  5. Introduction to Heating, Ventilation and Air Conditioning (HVAC). Instructor Edition. Introduction to Construction Series.

    Science.gov (United States)

    Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This instructor's guide contains the materials required to teach a competency-based introductory course in heating, ventilating, and air conditioning (HVAC) to students who have chosen to explore careers in construction. It contains three units: HVAC materials, HVAC tools, and applied skills. Each instructional unit includes some or all of the…

  6. Deposition of biological aerosols on HVAC heat exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Siegel, Jeffrey; Walker, Ian

    2001-09-01

    Many biologically active materials are transported as bioaerosols 1-10 {micro}m in diameter. These particles can deposit on cooling and heating coils and lead to serious indoor air quality problems. This paper investigates several of the mechanisms that lead to aerosol deposition on fin and tube heat exchangers. A model has been developed that incorporates the effects of several deposition mechanisms, including impaction, Brownian and turbulent diffusion, turbophoresis, thermophoresis, diffusiophoresis, and gravitational settling. The model is applied to a typical range of air velocities that are found in commercial and residential HVAC systems 1 - 6 m/s (200 - 1200 ft/min), particle diameters from 1 - 8 {micro}m, and fin spacings from 3.2 - 7.9 fins/cm (8 - 16 fins/inch or FPI). The results from the model are compared to results from an experimental apparatus that directly measures deposition on a 4.7 fins/cm (12 FPI) coil. The model agrees reasonably well with this measured data and suggests that cooling coils are an important sink for biological aerosols and consequently a potential source of indoor air quality problems.

  7. Static configurations and evolution of higher dimensional brane-dilaton black hole system

    CERN Document Server

    Nakonieczna, Anna; Moderski, Rafał; Rogatko, Marek

    2016-01-01

    Static configurations and a dynamical evolution of the system composed of a higher-dimensional spherically symmetric dilaton black hole and the Dirac-Goto-Nambu brane were investigated. The studies were conducted for three values of the dilaton coupling constant, describing the uncoupled case, the low-energy limit of the string theory and dimensionally reduced Klein-Kaluza theories. When the black hole is nonextremal, two types of static configurations are observed, a brane which intersects the black hole horizon and a brane not having any common points with the accompanying black hole. As the number of spacetime dimensions increases, the brane bend in the vicinity of the black hole disappears closer to its horizon. Dynamical evolution of the system results in an expulsion of the black hole from the brane. It proceeds faster for bigger values of the bulk spacetime dimension and thicker branes. The value of the dilatonic coupling constant does not influence neither the static configurations nor the dynamical b...

  8. A documentation tool for product configuration systems - improving the documentation task

    DEFF Research Database (Denmark)

    Hvam, Lars; Jensen, Klaes Ladeby

    2005-01-01

    essential tasks is thus to develop a complete and consistent product model which can reflect the actual product. A procedure for building product models has been developed at the Centre for Product Modelling (CPM), and the pro-cedure has been successfully applied in several industrial companies. CPM...... of a documentation tool for product configuration, based on CPM's procedure and experience from four Danish industrial companies which have applied the procedure. The requirements have been gathered and structured by using object-oriented system development techniques based on an analysis of the existing prod......-uct configuration processes of the companies. The analysis was based on the procedure for building product models as de-veloped at CPM, and revealed several common requirements within the different companies....

  9. Performance of a Kilowatt-Class Stirling Power Conversion System in a Thermodynamically Coupled Configuration

    Science.gov (United States)

    Geng, Steven M.; Briggs, Maxwell H.; Hervol, David S.

    2011-01-01

    A pair of 1-kWe free-piston Stirling power convertors has been modified into a thermodynamically coupled configuration, and performance map testing has been completed. This is the same configuration planned for the full-scale 12-kWe power conversion unit (PCU) that will be used in the Fission Power System Technology Demonstration Unit (TDU). The 1-kWe convertors were operated over a range of conditions to evaluate the effects of thermodynamic coupling on convertor performance and to identify any possible control challenges. The thermodynamically coupled convertor showed no measureable difference in performance from the baseline data collected when the engines were separate, and no major control issues were encountered during operation. The results of this test are guiding controller development and instrumentation selection for the TDU.

  10. Performance of a Kilowatt-Class Stirling Power Conversion System in a Thermodynamically-Coupled Configuration

    Science.gov (United States)

    Geng, S. M.; Briggs, M. H.; Hervol, D. S.

    A pair of 1kWe free-piston Stirling power convertors has been modified into a thermodynamically coupled configuration, and performance map testing has been completed. This is the same configuration planned for the full-scale 12 kWe power conversion unit (PCU) that will be used in the Fission Power System Technology Demonstration Unit (TDU). The 1-kWe convertors were operated over a range of conditions to evaluate the effects of thermodynamic coupling on convertor performance and to identify any possible control challenges. The thermodynamically coupled convertor showed no measurable difference in performance from the baseline data collected when the engines were separate and no major control issues were encountered during operation. The results of this test are guiding controller development and instrumentation selection for the TDU.

  11. Impact of product configuration systems on product profitability and costing accuracy

    DEFF Research Database (Denmark)

    Myrodia, Anna; Kristjansdottir, Katrin; Hvam, Lars

    2017-01-01

    This article aims at analyzing the impact of implementing a product configuration system (PCS) on the increased accuracy of the cost calculations and the increased profitability of the products. Companies that have implemented PCSs have achieved substantial benefits in terms of being more...... in control of their product assortment, making the right decisions in the sales phase and increasing sales of optimal products. These benefits should have an impact on the company's ability to make more accurate cost estimations in the sales phase, which can positively affect the products’ profitability....... However, previous studies have not addressed this relationship to a great extent. For that reason, a configure-to-order (CTO) manufacturing company was analyzed. A longitudinal field study was performed in which the accuracy of the cost calculations and the products’ profitability were analyzed before...

  12. OTEC platform configuration and integration study. Volume I. Systems engineering and integration. Final report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1978-04-01

    The economic success of an Ocean Thermal Energy Conversion (OTEC) system is highly dependent on a platform which provides adequate support for the power system, accommodates reliably the cold water pipe, and is most cost effective. The results of a study conducted for the Department of Energy to assess six generic types of platforms to determine the most satisfactory platform for severl potential sites are presented. The six platform configurations are ship, circular barge, semi-submersible, Tuned Sphere, submersible, and spar. These represent directional and symmetric types of platforms which operate on the surface, at the interface, and submerged. The five sites for this study were primarily New Orleans, Keahole Point (Hawaii), Brazil, and secondarily Key West and Puerto Rico. Electrical transmission of energy by submarine cable is the planned form of energy transmission for all sites except Brazil, where chemical conversion is to be the method of transmission. This study is devoted to the platform (or ocean systems) of the OTEC plant which is chiefly comprised of the hull and structure, the seawater system, the position control system, and miscellaneous support/assembly systems. The principal elements in the work breakdown structure for the commercial plants are presented. The assessment of the six platform configurations was conducted utilizing a baseline plan (100-MW(e) (Net)) and site (New Orleans) with variations from the baseline to cover the range of interested platforms and sites.

  13. A configurable electronics system for the ESS-Bilbao beam position monitors

    Science.gov (United States)

    Muguira, L.; Belver, D.; Etxebarria, V.; Varnasseri, S.; Arredondo, I.; del Campo, M.; Echevarria, P.; Garmendia, N.; Feuchtwanger, J.; Jugo, J.; Portilla, J.

    2013-09-01

    A versatile and configurable system has been developed in order to monitorize the beam position and to meet all the requirements of the future ESS-Bilbao Linac. At the same time the design has been conceived to be open and configurable so that it could eventually be used in different kinds of accelerators, independent of the charged particle, with minimal change. The design of the Beam Position Monitors (BPMs) system includes a test bench both for button-type pick-ups (PU) and striplines (SL), the electronic units and the control system. The electronic units consist of two main parts. The first part is an Analog Front-End (AFE) unit where the RF signals are filtered, conditioned and converted to base-band. The second part is a Digital Front-End (DFE) unit which is based on an FPGA board where the base-band signals are sampled in order to calculate the beam position, the amplitude and the phase. To manage the system a Multipurpose Controller (MC) developed at ESSB has been used. It includes the FPGA management, the EPICS integration and Archiver Instances. A description of the system and a comparison between the performance of both PU and SL BPM designs measured with this electronics system are fully described and discussed.

  14. Self Configurable Intelligent Distributed Antenna System for Resource Management in Multilayered Dense-nets

    DEFF Research Database (Denmark)

    Kumar, Ambuj; Mihovska, Albena Dimitrova; Prasad, Ramjee

    2016-01-01

    to their respective Base Stations (BS). Moreover, in earlier generations of MCC, antennas were deemed collocated with their respective BSs. Later, the concepts like Distributed Antenna Systems (DAS) and Cloud RAN (C-RAN) made it possible to place these antennas distant from their respective BSs. However, being mapped...... with their respective base stations, spectrum pooling and management at antenna end is not efficient. The situation worsens in Heterogeneous and Dense-net conditions in an Area of Interest (AoI). In this paper, we propose a DAS based intelligent architecture referred to as Self Configurable Intelligent Distributed...... Antenna System (SCIDAS) that can simultaneously accommodate multilayer communication environment over a common BS....

  15. Spectral behavior of the linear polarization degree at right-angle scattering configuration for nanoparticle systems

    Energy Technology Data Exchange (ETDEWEB)

    Setien, B; Albella, P; Saiz, J M; Gonzalez, F; Moreno, F, E-mail: morenof@unican.e [Grupo de Optica, Departamento de Fisica Aplicada, Universidad de Cantabria, Avda de los Castros S/N, 39005 Santander (Spain)

    2010-10-15

    We present a numerical study of the spectral evolution of the linear polarization degree at right-angle scattering configuration (P{sub L}(90{sup 0})) for two different particle systems: an isolated nanosphere and a nanodimer composed of two finite size spherical particles separated by a gap distance d. We shall focus on the influence of charge oscillation modes other than the dipolar on the linear polarization degree of the scattered light. The possibility of using this alternative parameter for characterizing nanoparticle systems and particle interaction is analyzed.

  16. Optimization of wind-marine hybrid power system configuration based on genetic algorithm

    Science.gov (United States)

    Shi, Hongda; Li, Linna; Zhao, Chenyu

    2017-08-01

    Multi-energy power systems can use energy generated from various sources to improve power generation reliability. This paper presents a cost-power generation model of a wind-tide-wave energy hybrid power system for use on a remote island, where the configuration is optimized using a genetic algorithm. A mixed integer programming model is used and a novel object function, including cost and power generation, is proposed to solve the boundary problem caused by existence of two goals. Using this model, the final optimized result is found to have a good fit with local resources.

  17. Distributed Configuration of Sensor Network for Fault Detection in Spatio-Temporal Systems

    Science.gov (United States)

    Patan, Maciej; Kowalów, Damian

    2017-01-01

    The problem of fault detection in spatio-temporal systems is formulated as that of maximizing the power of a parametric hypothesis test verifying the nominal state of the process under consideration. Then, adopting a pairwise communication schemes, a computational procedure is developed for the spatial configuration of the observation locations for sensor network which monitor changes in the underlying parameters of a distributed parameter system. As a result, the problem of planning the percentage of experimental effort spent at given sensor locations can be solved in a fully decentralized fashion. The approach is verified on a numerical example involving sensor selection for a convective diffusion process.

  18. Development and implementation of product configuration systems - a change management perspective

    DEFF Research Database (Denmark)

    Møldrup, Morten; Møller, Niels

    2004-01-01

    Product configuration systems (PCS) are IT-based expert systems, which contain product information and knowledge and in turn provide the basis for automating the decision-making processes in the order acquisition phase. Thereby PCS support and streamline the efforts of an organisations sales force...... of a change management perspective with emphasis on preventive initiatives taken to deal with possible expert and user resistance. In this respect the analysis reflects that the actual practice of change management in the twelve companies to a large extent is based purely on past experience and common sense...

  19. Recent advances in the Mercator-Ocean reanalysis system: Application to an Arctic configuration

    Science.gov (United States)

    Testut, Charles-Emmanuel; Garric, Gilles; Chanut, Jérome; Bricaud, Clément; Smith, Greg

    2015-04-01

    In the framework of the Myocean EU (FP7 and Horizon 2020) funded projects , Mercator Ocean, the French operational oceanography center, is in charge of the development and of the production of real time analysis and forecasts and reanalysis for the global ocean at the resolution of 1/12°. The operational systems are all based on the ocean and sea ice model NEMO and the multivariate data assimilation system SAM2 (Système d'Assimilation Mercator V2). The assimilation method is a reduced order Kalman filter based on SEEK formulation with bias correction scheme for temperature and salinity and an Incremental Analysis Update. The strong need of a realistic description of the mean state and variability of the rapid changing Arctic Ocean and its adjacent seas over the last decades motivated the use of the Canadian Arctic Ocean and Nordic seas configuration (CREG). This dedicated configuration at 1/12° developed by the Canadian research teams has been coupled to the multivariate data assimilation system SAM2. The objectives of this pan-Arctic platform is both to improve the sea ice assimilation method used in the Mercator Ocean and Canadian analysis and forecasting systems and to produce reanalysis over recent periods at lower numerical cost in order to prepare global higher resolution reanalysis. After a description of this Arctic reanalysis system, we present first results on the abilities of this configuration to reproduce sea ice extent and volume interannual variability without assimilation and, secondly, the impact of assimilating sea ice data on the sea ice cover with short hindcasts experiments.

  20. Configuration Reusing in On-Line Task Scheduling for Reconfigurable Computing Systems

    Institute of Scientific and Technical Information of China (English)

    Maisam Mansub Bassiri; Hadi Shahriar Shahhoseini

    2011-01-01

    Reconfigurable computing systems can be reconfigured at runtime and support partial reconfigurability which makes us able to execute tasks in a true multitasking manner. To manage such systems at runtime, a reconfigurable operating system is needed. The main part of this operating system is resource management unit which performs on-line scheduling and placement of hardware tasks at runtime. Reconfiguration overhead is an important obstacle that limits the performance of on-line scheduling algorithms in reconfigurable computing systems and increases the overall execution time. Configuration reusing (task reusing) can decrease reconfiguration overhead considerably, particularly in periodic applications or the applications in which the probability of tasks recurrence is high. In this paper, we present a technique called reusing-based scheduling (RBS), for on-line scheduling and placement in which configuration reusing is considered as a main characteristic in order to reduce reconfiguration overhead and decrease total execution time of the tasks. Several experiments have been conducted on the proposed algorithm. Obtained results show considerable improvement in overall execution time of the tasks.

  1. EMIR: a configurable hierarchical system for event monitoring and incident response

    Science.gov (United States)

    Deich, William T. S.

    2014-07-01

    The Event Monitor and Incident Response system (emir) is a flexible, general-purpose system for monitoring and responding to all aspects of instrument, telescope, and general facility operations, and has been in use at the Automated Planet Finder telescope for two years. Responses to problems can include both passive actions (e.g. generating alerts) and active actions (e.g. modifying system settings). Emir includes a monitor-and-response daemon, plus graphical user interfaces and text-based clients that automatically configure themselves from data supplied at runtime by the daemon. The daemon is driven by a configuration file that describes each condition to be monitored, the actions to take when the condition is triggered, and how the conditions are aggregated into hierarchical groups of conditions. Emir has been implemented for the Keck Task Library (KTL) keyword-based systems used at Keck and Lick Observatories, but can be readily adapted to many event-driven architectures. This paper discusses the design and implementation of Emir , and the challenges in balancing the competing demands for simplicity, flexibility, power, and extensibility. Emir 's design lends itself well to multiple purposes, and in addition to its core monitor and response functions, it provides an effective framework for computing running statistics, aggregate values, and summary state values from the primitive state data generated by other subsystems, and even for creating quick-and-dirty control loops for simple systems.

  2. The Control and Configuration Software of the ATLAS Data Acquisition System: Upgrades for LHC Run 2

    CERN Document Server

    Aleksandrov, Igor; The ATLAS collaboration; Avolio, Giuseppe; Caprini, Mihai; Corso-Radu, Alina; D'ascanio, Matteo; De Castro Vargas Fernandes, Julio; Kazarov, Andrei; Kolobara, Bernard; Lankford, Andrew; Laurent, Florian; Lehmann Miotto, Giovanna; Magnoni, Luca; Papaevgeniou, Lykourgos; Ryabov, Yury; Santos, Alejandro; Seixas, Jose; Soloviev, Igor; Unel, Gokhan; Yasu, Yoshiji

    2016-01-01

    The Trigger and Data Acquisition (TDAQ) system of the ATLAS detector at the Large Hadron Collider (LHC) at CERN is composed of a large number of distributed hardware and software components which in a coordinated manner provide the data-taking functionality of the overall system. The Controls and Configuration (CC) software offers services to configure, control and monitor the TDAQ system. It is a framework which provides essentially the glue that holds the various sub-systems together. While the overall architecture, established at the end of the 90’s, has proven to be solid and flexible, many software components (from core services, like the Run Control and the error management system, to end- user tools) have undergone a complete redesign or re-implementation during the LHC’s Long Shutdown I period. The upgrades were driven by the need to fold-in the additional requirements that appeared in the course of LHC’s Run 1, to profit from new technologies and to re-factorize and cleanup the code. This paper...

  3. Reexamining Organizational Configurations: An Update, Validation, and Expansion of the Taxonomy of Health Networks and Systems

    Science.gov (United States)

    Dubbs, Nicole L; Bazzoli, Gloria J; Shortell, Stephen M; Kralovec, Peter D

    2004-01-01

    Objectives To (a) assess how the original cluster categories of hospital-led health networks and systems have changed over time; (b) identify any new patterns of cluster configurations; and (c) demonstrate how additional data can be used to refine and enhance the taxonomy measures. Data Sources 1994 and 1998 American Hospital Association (AHA) Annual Survey of Hospitals. Study Design As in the original taxonomy, separate cluster solutions are identified for health networks and health systems by applying three strategic/structural dimensions (differentiation, integration, and centralization) to three components of the health service/product continuum (hospital services, physician arrangements, and provider-based insurance activities). Data Extraction Methods Factor, cluster, and discriminant analyses are used to analyze the 1998 data. Descriptive and comparative methods are used to analyze the updated 1998 taxonomy relative to the original 1994 version. Principal Findings The 1998 cluster categories are similar to the original taxonomy, however, they reveal some new organizational configurations. For the health networks, centralization of product/service lines is occurring more selectively than in the past. For the health systems, participation has grown in and dispersed across a more diverse set of decentralized organizational forms. For both networks and systems, the definition of centralization has changed over time. Conclusions In its updated form, the taxonomy continues to provide policymakers and practitioners with a descriptive and contextual framework against which to assess organizational programs and policies. There is a need to continue to revisit the taxonomy from time to time because of the persistent evolution of the U.S. health care industry and the consequent shifting of organizational configurations in this arena. There is also value in continuing to move the taxonomy in the direction of refinement/expansion as new opportunities become available

  4. Fine- and hyperfine structure investigations of even configuration system of atomic terbium

    Science.gov (United States)

    Stefanska, D.; Elantkowska, M.; Ruczkowski, J.; Furmann, B.

    2017-03-01

    In this work a parametric study of the fine structure (fs) and the hyperfine structure (hfs) for the even-parity configurations of atomic terbium (Tb I) is presented, based in considerable part on the new experimental results. Measurements on 134 spectral lines were performed by laser induced fluorescence (LIF) in a hollow cathode discharge lamp; on this basis, the hyperfine structure constants A and B were determined for 52 even-parity levels belonging to the configurations 4f85d6s2, 4f85d26s or 4f96s6p; in all the cases those levels were involved in the transitions investigated as the lower levels. For 40 levels the hfs was examined for the first time, and for the remaining 12 levels the new measurements supplement our earlier results. As a by-product, also preliminary values of the hfs constants for 84 odd-parity levels were determined (the investigations of the odd-parity levels system in the terbium atom are still in progress). This huge amount of new experimental data, supplemented by our earlier published results, were considered for the fine and hyperfine structure analysis. A multi-configuration fit of 7 configurations was performed, taking into account second-order of perturbation theory, including the effects of closed shell-open shell excitations. Predicted values of the level energies, as well as of magnetic dipole and electric quadrupole hyperfine structure constants A and B, are quoted in cases when no experimental values are available. By combining our experimental data with our own semi-empirical procedure it was possible to identify correctly the lower and upper level of the line 544.1440 nm measured by Childs with the use of the atomic-beam laser-rf double-resonance technique (Childs, J Opt Soc Am B 9;1992:191-6).

  5. Self-Correcting HVAC Controls: Algorithms for Sensors and Dampers in Air-Handling Units

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, Nicholas; Brambley, Michael R.; Katipamula, Srinivas

    2009-12-31

    This report documents the self-correction algorithms developed in the Self-Correcting Heating, Ventilating and Air-Conditioning (HVAC) Controls project funded jointly by the Bonneville Power Administration and the Building Technologies Program of the U.S. Department of Energy. The algorithms address faults for temperature sensors, humidity sensors, and dampers in air-handling units and correction of persistent manual overrides of automated control systems. All faults considered create energy waste when left uncorrected as is frequently the case in actual systems.

  6. Resonant capture of multiple planet systems under dissipation and stable orbital configurations

    CERN Document Server

    Voyatzis, George

    2016-01-01

    Migration of planetary systems caused by the action of dissipative forces may lead the planets to be trapped in a resonance. In this work we study the conditions and the dynamics of such resonant trapping. Particularly, we are interested in finding out whether resonant capture ends up in a long-term stable planetary configuration. For two planet systems we associate the evolution of migration with the existence of families of periodic orbits in the phase space of the three-body problem. The family of circular periodic orbits exhibits a gap at the 2:1 resonance and an instability and bifurcation at the 3:1 resonance. These properties explain the high probability of 2:1 and 3:1 resonant capture at low eccentricities. Furthermore, we study the resonant capture of three-planet systems. We show that such a resonant capture is possible and can occur under particular conditions. Then, from the migration path of the system, stable three-planet configurations, either symmetric or asymmetric, can be determined.

  7. Optimal Environmental Performance of Water-cooled Chiller System with All Variable Speed Configurations

    Science.gov (United States)

    Yu, Fu Wing; Chan, Kwok Tai

    This study investigates how the environmental performance of water-cooled chiller systems can be optimized by applying load-based speed control to all the system components. New chiller and cooling tower models were developed using a transient systems simulation program called TRNSYS 15 in order to assess the electricity and water consumption of a chiller plant operating for a building cooling load profile. The chiller model was calibrated using manufacturer's performance data and used to analyze the coefficient of performance when the design and control of chiller components are changed. The NTU-effectiveness approach was used for the cooling tower model to consider the heat transfer effectiveness at various air-to-water flow ratios and to identify the makeup water rate. Applying load-based speed control to the cooling tower fans and pumps could save an annual plant operating cost by around 15% relative to an equivalent system with constant speed configurations.

  8. Airflow Measurement of the Car HVAC Unit Using Hot-wire Anemometry

    Directory of Open Access Journals (Sweden)

    Fojtlín Miloš

    2016-01-01

    Full Text Available Thermal environment in a vehicular cabin significantly influence drivers’ fatigue and passengers’ thermal comfort. This environment is traditionally managed by HVAC cabin system that distributes air and modifies its properties. In order to simulate cabin thermal behaviour, amount of the air led through car vents must be determined. The aim of this study was to develop methodology to measure airflow from the vents, and consequently calculate corresponding air distribution coefficients. Three climatic cases were selected to match European winter, summer, and spring / fall conditions. Experiments were conducted on a test vehicle in a climatic chamber. The car HVAC system was set to automatic control mode, and the measurements were executed after the system stabilisation—each case was independently measured three times. To be able to evaluate precision of the method, the airflow was determined at the system inlet (HVAC suction and outlet (each vent, and the total airflow values were compared. The airflow was calculated by determining a mean value of the air velocity multiplied by an area of inlet / outlet cross-section. Hot-wire anemometry was involved to measure the air velocity. Regarding the summer case, total airflow entering the cabin was around 57 l s-1 with 60 % of the air entering the cabin through dashboard vents; no air was supplied to the feet compartment. The remaining cases had the same total airflow of around 42 l s-1, and the air distribution was focused mainly on feet and windows. The inlet and outlet airflow values show a good match with a maximum mass differential of 8.3 %.

  9. Airflow Measurement of the Car HVAC Unit Using Hot-wire Anemometry

    Science.gov (United States)

    Fojtlín, Miloš; Planka, Michal; Fišer, Jan; Pokorný, Jan; Jícha, Miroslav

    2016-03-01

    Thermal environment in a vehicular cabin significantly influence drivers' fatigue and passengers' thermal comfort. This environment is traditionally managed by HVAC cabin system that distributes air and modifies its properties. In order to simulate cabin thermal behaviour, amount of the air led through car vents must be determined. The aim of this study was to develop methodology to measure airflow from the vents, and consequently calculate corresponding air distribution coefficients. Three climatic cases were selected to match European winter, summer, and spring / fall conditions. Experiments were conducted on a test vehicle in a climatic chamber. The car HVAC system was set to automatic control mode, and the measurements were executed after the system stabilisation—each case was independently measured three times. To be able to evaluate precision of the method, the airflow was determined at the system inlet (HVAC suction) and outlet (each vent), and the total airflow values were compared. The airflow was calculated by determining a mean value of the air velocity multiplied by an area of inlet / outlet cross-section. Hot-wire anemometry was involved to measure the air velocity. Regarding the summer case, total airflow entering the cabin was around 57 l s-1 with 60 % of the air entering the cabin through dashboard vents; no air was supplied to the feet compartment. The remaining cases had the same total airflow of around 42 l s-1, and the air distribution was focused mainly on feet and windows. The inlet and outlet airflow values show a good match with a maximum mass differential of 8.3 %.

  10. Ventilation, temperature, and HVAC characteristics in small and medium commercial buildings in California.

    Science.gov (United States)

    Bennett, D H; Fisk, W; Apte, M G; Wu, X; Trout, A; Faulkner, D; Sullivan, D

    2012-08-01

    This field study of 37 small and medium commercial buildings throughout California obtained information on ventilation rate, temperature, and heating, ventilating, and air-conditioning (HVAC) system characteristics. The study included seven retail establishments; five restaurants; eight offices; two each of gas stations, hair salons, healthcare facilities, grocery stores, dental offices, and fitness centers; and five other buildings. Fourteen (38%) of the buildings either could not or did not provide outdoor air through the HVAC system. The air exchange rate averaged 1.6 (s.d. = 1.7) exchanges per hour and was similar between buildings with and without outdoor air supplied through the HVAC system, indicating that some buildings have significant leakage or ventilation through open windows and doors. Not all buildings had sufficient air exchange to meet ASHRAE 62.1 Standards, including buildings used for fitness centers, hair salons, offices, and retail establishments. The majority of the time, buildings were within the ASHRAE temperature comfort range. Offices were frequently overcooled in the summer. All of the buildings had filters, but over half the buildings had a filter with a minimum efficiency reporting value rating of 4 or lower, which are not very effective for removing fine particles. Most U.S. commercial buildings (96%) are small- to medium-sized, using nearly 18% of the country's energy, and sheltering a large population daily. Little is known about the ventilation systems in these buildings. This study found a wide variety of ventilation conditions, with many buildings failing to meet relevant ventilation standards. Regulators may want to consider implementing more complete building inspections at commissioning and point of sale. © 2012 John Wiley & Sons A/S.

  11. Managing complexity of product mix and production flow in configure-to-order production systems

    DEFF Research Database (Denmark)

    Myrodia, Anna; Bonev, Martin; Hvam, Lars

    2014-01-01

    In designing configure-to-order production systems for a growing product variety, companies are challenged with an increased complexity for obtaining high productivity levels and cost-effectiveness. In academia several optimization methods and conceptual frameworks for substituting components......, or increasing lot sizes and storage capacity have been proposed. Our study presents a practical framework for quantifying the impact of a two-way substitution at different production stages and its impact on storage and machinery utilization. In a case study we quantify the relation between substitution, lot...... sizing and capacity utilization, while maintaining the production capacity as well as the external product variety....

  12. Identification of profitable areas to apply product configuration systems in Engineering-To-Order companies

    DEFF Research Database (Denmark)

    Kristjansdottir, Katrin; Hvam, Lars; Shafiee, Sara

    2015-01-01

    This article suggests a systematic framework for identifying potential areas, where Engineering-To-Order (ETO) companies may increase their profit-ability by implementing a Product Configuration System (PCS). In order to do so a three-step framework is proposed based on literature. The starting...... point is to conduct a profitability analysis to determine the accuracy of the cost estima-tions, and based on that the reason for the deviations across different projects is found. The next step is to generate the scope for different scenarios that aim to improve the current situation. Finally...

  13. CFD Analysis of Flexible Thermal Protection System Shear Configuration Testing in the LCAT Facility

    Science.gov (United States)

    Ferlemann, Paul G.

    2014-01-01

    This paper documents results of computational analysis performed after flexible thermal protection system shear configuration testing in the LCAT facility. The primary objectives were to predict the shear force on the sample and the sensitivity of all surface properties to the shape of the sample. Bumps of 0.05, 0.10,and 0.15 inches were created to approximate the shape of some fabric samples during testing. A large amount of information was extracted from the CFD solutions for comparison between runs and also current or future flight simulations.

  14. Equilibrium configurations of the tethered three-body formation system and their nonlinear dynamics

    Institute of Scientific and Technical Information of China (English)

    Ming Xu; Jian-Min Zhu; Tian Tan; Shi-Jie Xu

    2012-01-01

    This paper considers nonlinear dynamics of tethered three-body formation system with their centre of mass staying on a circular orbit around the Earth,and applies the theory of space manifold dynamics to deal with the nonlinear dynamical behaviors of the equilibrium configurations of the system.Compared with the classical circular restricted three body system,sixteen equilibrium configurations are obtained globally from the geometry of pseudo-potential energy surface,four of which were omitted in the previous research.The periodic Lyapunov orbits and their invariant manifolds near the hyperbolic equilibria are presented,and an iteration procedure for identifying Lyapunov orbit is proposed based on the differential correction algorithm.The non-transversal intersections between invariant manifolds are addressed to generate homoclinic and heteroclinic trajectories between the Lyapunov orbits.(3,3)-and (2,1)-heteroclinic trajectories from the neighborhood of one collinear equilibrium to that of another one,and (3,6)-and (2,1)-homoclinic trajectories from and to the neighborhood of the same equilibrium,are obtained based on the Poincaré mapping technique.

  15. Reliable measurements for an image-derived sample volume in an open-configuration MR system

    Science.gov (United States)

    Han, Bong Soo; Lee, Man Woo; Hong, Cheolpyo

    2016-11-01

    Open-configuration magnetic resonance (MR) systems are becoming desirable for volume measurements of off-center samples due to their non-claustrophobic system configuration, excellent soft-tissue contrast, high efficiency, and low-cost. However, geometric distortion is produced by the unwanted background magnetic field and hinders volume measurements. The present study describes the characteristics of geometric distortion in off-center samples such as the thigh muscle and adipose tissue measurements using an open-type MR system. The American Association of Physicists in Medicine uniformity and linearity phantom was used for the detection and the evaluation of the geometric distortion. The geometric distortion decreased near the isocenter and increased toward the off-center. A cylindrical phantom image was acquired at the isocenter and was used as the distortion-free, reference image. Two cylindrical phantoms were scanned off-center at a position analogous to that of the human thigh. The differences between the two cylindrical phantom volumes and the reference volume were 1.62 % ± 0.16 and 5.18 % ± 0.14. Off-center-related MR imaging requires careful consideration for image interpretation and volumetric assessment of tissue.

  16. Reducing Building HVAC Costs with Site-Recovery Energy

    Science.gov (United States)

    Pargeter, Stephen J.

    2012-01-01

    Building owners are caught between two powerful forces--the need to lower energy costs and the need to meet or exceed outdoor air ventilation regulations for occupant health and comfort. Large amounts of energy are wasted each day from commercial, institutional, and government building sites as heating, ventilation, and air conditioning (HVAC)…

  17. Illinois Occupational Skill Standards: HVAC/R Technician Cluster.

    Science.gov (United States)

    Illinois Occupational Skill Standards and Credentialing Council, Carbondale.

    This document, which is intended to serve as a guide for work force preparation program providers, details the Illinois occupational skill standards for programs preparing students for employment in jobs in the heating, ventilation, air conditioning, and refrigeration (HVAC/R) industry. Agency partners involved in this project include: the…

  18. Maximize Benefits, Minimize Risk: Selecting the Right HVAC Firm.

    Science.gov (United States)

    Golden, James T.

    1993-01-01

    An informal survey of 20 major urban school districts found that 40% were currently operating in a "break down" maintenance mode. A majority, 57.9%, also indicated they saw considerable benefits in contracting for heating, ventilating, and air conditioning (HVAC) maintenance services with outside firms. Offers guidelines in selecting HVAC…

  19. Maximize Benefits, Minimize Risk: Selecting the Right HVAC Firm.

    Science.gov (United States)

    Golden, James T.

    1993-01-01

    An informal survey of 20 major urban school districts found that 40% were currently operating in a "break down" maintenance mode. A majority, 57.9%, also indicated they saw considerable benefits in contracting for heating, ventilating, and air conditioning (HVAC) maintenance services with outside firms. Offers guidelines in selecting…

  20. Reference frame for Product Configuration

    DEFF Research Database (Denmark)

    Ladeby, Klaes Rohde; Oddsson, Gudmundur Valur

    2011-01-01

    on configuration systems in the shape of anecdotal reporting on the development of information systems that perhaps support the configuration task – perhaps not. Consequently, the definition of configuration has become ambiguous as different research groups defines configuration differently. This paper propose...... a reference frame for configuration that permits 1) a more precise understanding of a configuration system, 2) a understanding of how the configuration system relate to other systems, and 3) a definition of the basic concepts in configuration. The total configuration system, together with the definition...

  1. Impact of fiber ring laser configuration on detection capabilities in FBG based sensor systems

    Science.gov (United States)

    Osuch, Tomasz; Kossek, Tomasz; Markowski, Konrad

    2014-11-01

    In this paper fiber ring lasers (FRL) as interrogation units for distributed fiber Bragg grating (FBG) based sensor networks are studied. In particular, two configurations of the fiber laser with erbium-doped fiber amplifier (EDFA) and semiconductor optical amplifier (SOA) as gain medium were analyzed. In the case of EDFA-based fiber interrogation systems, CW as well as active-mode locking operation were taken into account. The influence of spectral overlapping of FBGs spectra on detection capabilities of examined FRLs are presented. Experimental results show that the SOA-based fiber laser interrogation unit can operate as a multi-parametric sensing system. In turn, using an actively mode-locked fiber ring laser with an EDFA, an electronically switchable FBG based sensing system can be realized.

  2. Loss evaluation of HVAC and HVDC transmission solutions for large offshore wind farms

    Energy Technology Data Exchange (ETDEWEB)

    Negra, N. Barberis [Politecnico of Turin, Department of Electrical Engineering (Italy); Todorovic, J. [ELEKTROPRENOS, Banja Luka (Bosnia and Herzegovina); Ackermann, T. [Royal Institute of Technology, Teknikringen 33, 10044 Stockholm (Sweden)

    2006-07-15

    This paper presents a comparison of transmission losses for different technical transmission solutions for large offshore wind farms. Three technical solutions are analyzed, i.e. HVAC, HVDC Line Commutated Converter (LCC) and HVDC Voltage Source Converter (VSC). The losses for each technology are calculated for wind farms with different ratings and various distances to shore. In addition, solutions with combinations of two and the three different transmission technologies are analyzed and compared. Based on this comparison, further analysis regarding the economical feasibility can be performed in order to determine the most economic solutions for the transmission system of an offshore wind farm. (author)

  3. Conceptualizing Embedded Configuration

    DEFF Research Database (Denmark)

    Oddsson, Gudmundur Valur; Hvam, Lars; Lysgaard, Ole

    2006-01-01

    and services. The general idea can be named embedded configuration. In this article we intend to conceptualize embedded configuration, what it is and is not. The difference between embedded configuration, sales configuration and embedded software is explained. We will look at what is needed to make embedded...... configuration systems. That will include requirements to product modelling techniques. An example with consumer electronics will illuminate the elements of embedded configuration in settings that most can relate to. The question of where embedded configuration would be relevant is discussed, and the current...

  4. Developing An Effective Strategy to Configure Assembly Systems Using Lean Concepts

    Directory of Open Access Journals (Sweden)

    M.Eswaramoorthi

    2010-12-01

    Full Text Available The manufacturing industry has been pushed to adopt more effective production strategies to meet the challenges of shorter life cycle, higher quality, lower cost and wider variety of customer demands. This increased emphasis on achieving highly adaptive manufacturing with reduction in manufacturing costs and better utilization of manufacturing resources force to implementing new and efficient management techniques in their manufacturing operations. Some of the established tools in this context are lean practices. In manufacturing, assembly is one of the major activities that combine the machined components into final product. Decision on appropriate facility layout and viable assembly sequence (line balancing adaptable to takt time requirement with cost benefit is a challenging task. This paper proposes an integrated cost model for a typical assembly process to determine cost per part more precisely by considering seven types of "contributing factors". This procedure is performed under different takt time conditions to configure the assembly system in terms of cost per piece and to decide the adaptable layout. A prototype assembly system is established in this research to demonstrate the effectiveness of the cost model. The results show that there are significant variations in cost per piece with respect to changes in layout configurations and takt time.

  5. Analysis of electric energy consumption of automatic milking systems in different configurations and operative conditions.

    Science.gov (United States)

    Calcante, Aldo; Tangorra, Francesco M; Oberti, Roberto

    2016-05-01

    Automatic milking systems (AMS) have been a revolutionary innovation in dairy cow farming. Currently, more than 10,000 dairy cow farms worldwide use AMS to milk their cows. Electric consumption is one of the most relevant and uncontrollable operational cost of AMS, ranging between 35 and 40% of their total annual operational costs. The aim of the present study was to measure and analyze the electric energy consumption of 4 AMS with different configurations: single box, central unit featuring a central vacuum system for 1 cow unit and for 2 cow units. The electrical consumption (daily consumption, daily consumption per cow milked, consumption per milking, and consumption per 100L of milk) of each AMS (milking unit + air compressor) was measured using 2 energy analyzers. The measurement period lasted 24h with a sampling frequency of 0.2Hz. The daily total energy consumption (milking unit + air compressor) ranged between 45.4 and 81.3 kWh; the consumption per cow milked ranged between 0.59 and 0.99 kWh; the consumption per milking ranged between 0.21 and 0.33 kWh; and the consumption per 100L of milk ranged between 1.80 to 2.44 kWh according to the different configurations and operational contexts considered. Results showed that AMS electric consumption was mainly conditioned by farm management rather than machine characteristics/architectures. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  6. Random-fractal Ansatz for the configurations of two-dimensional critical systems

    Science.gov (United States)

    Lee, Ching Hua; Ozaki, Dai; Matsueda, Hiroaki

    2016-12-01

    Critical systems have always intrigued physicists and precipitated the development of new techniques. Recently, there has been renewed interest in the information contained in the configurations of classical critical systems, whose computation do not require full knowledge of the wave function. Inspired by holographic duality, we investigated the entanglement properties of the classical configurations (snapshots) of the Potts model by introducing an Ansatz ensemble of random fractal images. By virtue of the central limit theorem, our Ansatz accurately reproduces the entanglement spectra of actual Potts snapshots without any fine tuning of parameters or artificial restrictions on ensemble choice. It provides a microscopic interpretation of the results of previous studies, which established a relation between the scaling behavior of snapshot entropy and the critical exponent. More importantly, it elucidates the role of ensemble disorder in restoring conformal invariance, an aspect previously ignored. Away from criticality, the breakdown of scale invariance leads to a renormalization of the parameter Σ in the random fractal Ansatz, whose variation can be used as an alternative determination of the critical exponent. We conclude by providing a recipe for the explicit construction of fractal unit cells consistent with a given scaling exponent.

  7. The Cultural Analysis of Soft Systems Methodology and the Configuration Model of Organizational Culture

    Directory of Open Access Journals (Sweden)

    Jürgen Staadt

    2015-06-01

    Full Text Available Organizations that find themselves within a problematic situation connected with cultural issues such as politics and power require adaptable research and corresponding modeling approaches so as to grasp the arrangements of that situation and their impact on the organizational development. This article originates from an insider-ethnographic intervention into the problematic situation of the leading public housing provider in Luxembourg. Its aim is to describe how the more action-oriented cultural analysis of soft systems methodology and the theory-driven configuration model of organizational culture are mutually beneficial rather than contradictory. The data collected between 2007 and 2013 were analyzed manually as well as by means of ATLAS.ti. Results demonstrate that the cultural analysis enables an in-depth understanding of the power-laden environment within the organization bringing about the so-called “socio-political system” and that the configuration model makes it possible to depict the influence of that system on the whole organization. The overall research approach thus contributes toward a better understanding of the influence and the impact of oppressive social environments and evolving power relations on the development of an organization.

  8. Economic Investigation of Different Configurations of Inclined Solar Water Desalination Systems

    Directory of Open Access Journals (Sweden)

    O. Phillips Agboola

    2014-02-01

    Full Text Available This study empirically investigated the performance of four configurations of inclined solar water desalination (ISWD system for parameters such as daily production, efficiency, system cost, and distilled water production cost. The empirical findings show that in terms of daily productivity improved inclined solar water desalination (IISWD performed best with 6.41 kg/m2/day while improved inclined solar water desalination with wire mesh (IISWDWM produced the least with 3.0 kg/m2/day. In terms of cost price of the systems, the control system inclined solar water desalination (ISWD is the cheapest while IISWDWM is the most expensive system. Distilled water cost price ranges from 0.059 TL/kg, for IISWDW, to 0.134 TL/kg, for IISWDWM system. All the systems are economically and technically feasible as a solar desalination system for potable water in northern Cyprus. Potable water from vendors/hawkers ranges from 0.2 to 0.3 TL/kg.

  9. A self-configuring control system for storage and computing departments at INFN-CNAF Tierl

    Science.gov (United States)

    Gregori, Daniele; Dal Pra, Stefano; Ricci, Pier Paolo; Pezzi, Michele; Prosperini, Andrea; Sapunenko, Vladimir

    2015-05-01

    The storage and farming departments at the INFN-CNAF Tier1[1] manage approximately thousands of computing nodes and several hundreds of servers that provides access to the disk and tape storage. In particular, the storage server machines should provide the following services: an efficient access to about 15 petabytes of disk space with different cluster of GPFS file system, the data transfers between LHC Tiers sites (Tier0, Tier1 and Tier2) via GridFTP cluster and Xrootd protocol and finally the writing and reading data operations on magnetic tape backend. One of the most important and essential point in order to get a reliable service is a control system that can warn if problems arise and which is able to perform automatic recovery operations in case of service interruptions or major failures. Moreover, during daily operations the configurations can change, i.e. if the GPFS cluster nodes roles can be modified and therefore the obsolete nodes must be removed from the control system production, and the new servers should be added to the ones that are already present. The manual management of all these changes is an operation that can be somewhat difficult in case of several changes, it can also take a long time and is easily subject to human error or misconfiguration. For these reasons we have developed a control system with the feature of self-configure itself if any change occurs. Currently, this system has been in production for about a year at the INFN-CNAF Tier1 with good results and hardly any major drawback. There are three major key points in this system. The first is a software configurator service (e.g. Quattor or Puppet) for the servers machines that we want to monitor with the control system; this service must ensure the presence of appropriate sensors and custom scripts on the nodes to check and should be able to install and update software packages on them. The second key element is a database containing information, according to a suitable format, on

  10. Constrained sessile drop as a new configuration to measure low surface tension in lung surfactant systems.

    Science.gov (United States)

    Yu, Laura M Y; Lu, James J; Chan, Yawen W; Ng, Amy; Zhang, Ling; Hoorfar, Mina; Policova, Zdenka; Grundke, Karina; Neumann, A Wilhelm

    2004-08-01

    Existing methodology for surface tension measurements based on drop shapes suffers from the shortcoming that it is not capable to function at very low surface tension if the liquid dispersion is opaque, such as therapeutic lung surfactants at clinically relevant concentrations. The novel configuration proposed here removes the two big restrictions, i.e., the film leakage problem that is encountered with such methods as the pulsating bubble surfactometer as well as the pendant drop arrangement, and the problem of the opaqueness of the liquid, as in the original captive bubble arrangement. A sharp knife edge is the key design feature in the constrained sessile drop that avoids film leakage at low surface tension. The use of the constrained sessile drop configuration in conjunction with axisymmetric drop shape analysis to measure surface tension allows complete automation of the setup. Dynamic studies with lung surfactant can be performed readily by changing the volume of a sessile drop, and thus the surface area, by means of a motor-driven syringe. To illustrate the validity of using this configuration, experiments were performed using an exogenous lung surfactant preparation, bovine lipid extract surfactant (BLES) at 5.0 mg/ml. A comparison of results obtained for BLES at low concentration between the constrained sessile drop and captive bubble arrangement shows excellent agreement between the two approaches. When the surface area of the BLES film (0.5 mg/ml) was compressed by about the same amount in both systems, the minimum surface tensions attained were identical within the 95% confidence limits.

  11. Feasibility study of a solar power satellite system configured by formation flying

    Energy Technology Data Exchange (ETDEWEB)

    Takeichi, Noboru; Ueno, Hiroshi; Oda, Mitsushige [Japan Aerospace Exploration Agency (JAXA), Inst. of Space Technology and Aeronautics, Tsukuba, Ibaraki (Japan)

    2005-11-15

    This paper presents a new concept of a solar power satellite system configured by formation flying. In this concept, the solar power satellite system consists of sunlight reflectors and an energy generator-transmitter. The energy generator- transmitter is on a common GEO, and the reflectors are placed on the north and south by using solar pressure to raise their orbits from GEO. Therefore, the orbits of the reflectors and that of the energy generator-transmitter make three parallel GEOs. The feasibility of the concept and its requirements are also discussed, focusing on the orbital and attitude mechanics of the reflector. Because the tilt angle of the sunlight changes with the turning of the seasons, it is sometimes necessary to raise the orbit by thrusters especially around the solstice. For attitude dynamics, spin stabilization and thruster control are discussed as the attitude control strategies against the gravity gradient torque, which acts as a persistent periodic disturbance. (Author)

  12. Main-sequence progenitor configurations of the NN Ser candidate circumbinary planetary system are dynamically unstable

    CERN Document Server

    Mustill, Alexander J; Villaver, Eva; Veras, Dimitri; Davis, Philip J; Horner, Jonathan; Wittenmyer, Robert A

    2013-01-01

    Recent observations of the NN Serpentis post-common envelope binary system have revealed eclipse timing variations that have been attributed to the presence of two Jovian-mass exoplanets. Under the assumption that these planets are real and survived from the binary's Main Sequence state, we reconstruct initial binaries that give rise to the present NN Ser configuration and test the dynamical stability of the original system. Under standard assumptions about binary evolution, we find that survival of the planets through the entire Main Sequence life-time is very unlikely. Hence, we conclude that the planets are not survivors from before the Common Envelope phase, implying that either they formed recently out of material ejected from the primary, or that the observed signals are of non-planetary origin.

  13. High-precision atom localization via controllable spontaneous emission in a cycle-configuration atomic system.

    Science.gov (United States)

    Ding, Chunling; Li, Jiahua; Yu, Rong; Hao, Xiangying; Wu, Ying

    2012-03-26

    A scheme for realizing two-dimensional (2D) atom localization is proposed based on controllable spontaneous emission in a coherently driven cycle-configuration atomic system. As the spatial-position-dependent atom-field interaction, the frequency of the spontaneously emitted photon carries the information about the position of the atom. Therefore, by detecting the emitted photon one could obtain the position information available, and then we demonstrate high-precision and high-resolution 2D atom localization induced by the quantum interference between the multiple spontaneous decay channels. Moreover, we can achieve 100% probability of finding the atom at an expected position by choosing appropriate system parameters under certain conditions.

  14. Coordination Control of a Novel Wind Farm Configuration Including a Hydrogen Storage System and a Gas Turbine

    Directory of Open Access Journals (Sweden)

    Shihua Xuan

    2016-07-01

    Full Text Available This paper proposes a novel configuration that combines wind turbines, an electrolyzer, and a gas turbine with the corresponding generator. A control strategy for this configuration is also proposed. The purpose of this configuration and its control strategy is to make the wind farm work like a conventional power plant from a grid’s point of view. The final proposed configuration works properly with the proposed control strategy, the three times per revolution (3p oscillation frequency is removed and the output power fluctuations caused by wind fluctuation are compensated. The final power output of the proposed configuration is constant like that of a conventional power plant, and it can change according to the different requirements of the transmission system operator.

  15. Impact of tree planting configuration on canopy interception and soil hydrological properties: Implications for flood mitigation in silvopastoral systems

    Science.gov (United States)

    Lunka, Peter; Patil, Sopan

    2015-04-01

    Compaction of upper soil layers by intensive sheep grazing has been connected with increased local flood risk in silvopastoral systems. A 12 week field study was conducted at the Henfaes Research Station near Bangor, Wales to compare two silvopastoral configurations, trees planted in fenced off clumps and trees planted evenly spaced, in terms of canopy throughfall, soil water infiltration and soil bulk density. The study's aim was to characterize the potential of these tree planting configurations to reduce local flood risk. The study site (Henfaes) was established in 1992 on 14 ha of agricultural land and is part of the Silvopastoral National Network Experiment sites that have been set up across the UK to examine the potential of silvopasture and agroforestry on UK farms. Automated throughfall gauges were installed in each silvopastoral treatment along with a similarly designed control gauge located in the grazed control pasture. Soil water infiltration and bulk density were measured 20 times in a stratified random design for each treatment and the control. Soil infiltration capacity in the clumped configuration was significantly higher than in the even spaced configuration and control pasture. The clumped configuration had mean infiltration capacity 504% greater than the control pasture and 454% greater than the even spaced configuration. Canopy interception was higher in the clumped trees than in the evenly spaced trees. Average canopy interception was 34% in the clumped treatment and 28% in the evenly spaced treatment. Soil bulk density was lower in the clumped configuration than in the control pasture and evenly spaced configuration. Results suggest that in silvopastoral systems the clumped tree configuration is more likely to reduce local flood risk than the evenly spaced tree configuration due to enhanced infiltration and increased canopy interception.

  16. Multi-Objective Configuration Optimization of a Hybrid Energy Storage System

    Directory of Open Access Journals (Sweden)

    Shan Cheng

    2017-02-01

    Full Text Available This study aims to investigate multi-objective configuration optimization of a hybrid energy storage system (HESS. In order to maximize the stability of the wind power output with minimized HESS investment, a multi-objective model for optimal HESS configuration has been established, which proposes decreasing the installation and operation & maintenance costs of an HESS and improving the compensation satisfaction rate of wind power fluctuation. Besides, fuzzy control has been used to allocate power in the HESS for lengthening battery lifetime and ensuring HESS with enough energy to compensate the fluctuation of the next time interval. Instead of converting multiple objectives into one, a multi-objective particle swarm optimization with integration of bacteria quorum sensing and circular elimination (BC-MOPSO has been applied to provide diverse alternative solutions. In order to illustrate the feasibility and effectiveness of the proposed model and the application of BC-MOPSO, simulations along with analysis and discussion are carried out. The results verified the feasibility and effectiveness of the proposed approach.

  17. Adaptation of the human visual system to the statistics of letters and line configurations.

    Science.gov (United States)

    Chang, Claire H C; Pallier, Christophe; Wu, Denise H; Nakamura, Kimihiro; Jobert, Antoinette; Kuo, W-J; Dehaene, Stanislas

    2015-10-15

    By adulthood, literate humans have been exposed to millions of visual scenes and pages of text. Does the human visual system become attuned to the statistics of its inputs? Using functional magnetic resonance imaging, we examined whether the brain responses to line configurations are proportional to their natural-scene frequency. To further distinguish prior cortical competence from adaptation induced by learning to read, we manipulated whether the selected configurations formed letters and whether they were presented on the horizontal meridian, the familiar location where words usually appear, or on the vertical meridian. While no natural-scene frequency effect was observed, we observed letter-status and letter frequency effects on bilateral occipital activation, mainly for horizontal stimuli. The findings suggest a reorganization of the visual pathway resulting from reading acquisition under genetic and connectional constraints. Even early retinotopic areas showed a stronger response to letters than to rotated versions of the same shapes, suggesting an early visual tuning to large visual features such as letters.

  18. Synthesizing Configurable Biochemical Implementation of Linear Systems from Their Transfer Function Specifications.

    Directory of Open Access Journals (Sweden)

    Tai-Yin Chiu

    Full Text Available The ability to engineer synthetic systems in the biochemical context is constantly being improved and has a profound societal impact. Linear system design is one of the most pervasive methods applied in control tasks, and its biochemical realization has been proposed by Oishi and Klavins and advanced further in recent years. However, several technical issues remain unsolved. Specifically, the design process is not fully automated from specification at the transfer function level, systems once designed often lack dynamic adaptivity to environmental changes, matching rate constants of reactions is not always possible, and implementation may be approximative and greatly deviate from the specifications. Building upon the work of Oishi and Klavins, this paper overcomes these issues by introducing a design flow that transforms a transfer-function specification of a linear system into a set of chemical reactions, whose input-output response precisely conforms to the specification. This system is implementable using the DNA strand displacement technique. The underlying configurability is embedded into primitive components and template modules, and thus the entire system is adaptive. Simulation of DNA strand displacement implementation confirmed the feasibility and superiority of the proposed synthesis flow.

  19. Synthesizing Configurable Biochemical Implementation of Linear Systems from Their Transfer Function Specifications.

    Science.gov (United States)

    Chiu, Tai-Yin; Chiang, Hui-Ju K; Huang, Ruei-Yang; Jiang, Jie-Hong R; Fages, François

    2015-01-01

    The ability to engineer synthetic systems in the biochemical context is constantly being improved and has a profound societal impact. Linear system design is one of the most pervasive methods applied in control tasks, and its biochemical realization has been proposed by Oishi and Klavins and advanced further in recent years. However, several technical issues remain unsolved. Specifically, the design process is not fully automated from specification at the transfer function level, systems once designed often lack dynamic adaptivity to environmental changes, matching rate constants of reactions is not always possible, and implementation may be approximative and greatly deviate from the specifications. Building upon the work of Oishi and Klavins, this paper overcomes these issues by introducing a design flow that transforms a transfer-function specification of a linear system into a set of chemical reactions, whose input-output response precisely conforms to the specification. This system is implementable using the DNA strand displacement technique. The underlying configurability is embedded into primitive components and template modules, and thus the entire system is adaptive. Simulation of DNA strand displacement implementation confirmed the feasibility and superiority of the proposed synthesis flow.

  20. A comprehensive workflow for general-purpose neural modeling with highly configurable neuromorphic hardware systems.

    Science.gov (United States)

    Brüderle, Daniel; Petrovici, Mihai A; Vogginger, Bernhard; Ehrlich, Matthias; Pfeil, Thomas; Millner, Sebastian; Grübl, Andreas; Wendt, Karsten; Müller, Eric; Schwartz, Marc-Olivier; de Oliveira, Dan Husmann; Jeltsch, Sebastian; Fieres, Johannes; Schilling, Moritz; Müller, Paul; Breitwieser, Oliver; Petkov, Venelin; Muller, Lyle; Davison, Andrew P; Krishnamurthy, Pradeep; Kremkow, Jens; Lundqvist, Mikael; Muller, Eilif; Partzsch, Johannes; Scholze, Stefan; Zühl, Lukas; Mayr, Christian; Destexhe, Alain; Diesmann, Markus; Potjans, Tobias C; Lansner, Anders; Schüffny, René; Schemmel, Johannes; Meier, Karlheinz

    2011-05-01

    In this article, we present a methodological framework that meets novel requirements emerging from upcoming types of accelerated and highly configurable neuromorphic hardware systems. We describe in detail a device with 45 million programmable and dynamic synapses that is currently under development, and we sketch the conceptual challenges that arise from taking this platform into operation. More specifically, we aim at the establishment of this neuromorphic system as a flexible and neuroscientifically valuable modeling tool that can be used by non-hardware experts. We consider various functional aspects to be crucial for this purpose, and we introduce a consistent workflow with detailed descriptions of all involved modules that implement the suggested steps: The integration of the hardware interface into the simulator-independent model description language PyNN; a fully automated translation between the PyNN domain and appropriate hardware configurations; an executable specification of the future neuromorphic system that can be seamlessly integrated into this biology-to-hardware mapping process as a test bench for all software layers and possible hardware design modifications; an evaluation scheme that deploys models from a dedicated benchmark library, compares the results generated by virtual or prototype hardware devices with reference software simulations and analyzes the differences. The integration of these components into one hardware-software workflow provides an ecosystem for ongoing preparative studies that support the hardware design process and represents the basis for the maturity of the model-to-hardware mapping software. The functionality and flexibility of the latter is proven with a variety of experimental results.