WorldWideScience

Sample records for humeral diaphyseal fractures

  1. Combined three-part humeral anterior fracture-dislocation and humeral shaft fracture treated with one-stage long stem shoulder hemiarthroplasty in an active elderly patient

    Directory of Open Access Journals (Sweden)

    Herzberg Guillaume

    2017-01-01

    Full Text Available Introduction: Injuries combining a humeral head fracture-dislocation and a shaft fracture of the ipsilateral humerus are very rare. They should be separated from extended fractures of the humeral head to the shaft [1]. Case report: We present the case of an active 84-year-old man who sustained a three-part fracture-dislocation of the proximal humerus combined with a long spiral humeral middle third diaphyseal fracture, after a ski fall. We were unable to find a similar case in the literature. He was treated with a long stem hemiarthroplasty, associated with screw osteosynthesis of the long spiral shaft fracture. The result after 30 months of follow-up was excellent, with good shoulder range of motion, good bone integration of the prosthesis and uneventful healing of the fracture. Conclusion: This treatment allowed this intrepid elderly patient to recover a normal quality of life, including driving his car and to return to skiing.

  2. Minimally invasive plate osteosynthesis for humerus diaphyseal fractures

    Directory of Open Access Journals (Sweden)

    M Shantharam Shetty

    2011-01-01

    Full Text Available Background: Minimally invasive plate osteosynthesis (MIPO technique is reported as a satisfactory procedure for the treatment of humeral shaft fractures by the anterior approach by several authors. However, none of the published reports had a significant follow-up nor have they reported patient outcomes. We evaluated the clinical, radiographic, and functional outcome over a minimum follow-up of 2 years using the same MIPO technique to humeral shaft fracture. Materials and Methods: 32 adult patients with diaphyseal fractures of the humerus treated with MIPO between June 2007 and October 2008 were included in the study. Patients with metabolic bone disease, polytrauma, and Gustilo and Anderson type 3 open fractures with injury severity score >16 were excluded from the study. All cases were treated with closed indirect reduction and locking plate fixation using the MIPO technique. The surgery time, radiation exposure, and time for union was noted. The shoulder and elbow function was assessed using the UCLA shoulder and Mayo elbow performance scores, respectively. Results: Of the 32 patients in the study, 19 were males and 13 were females. The mean age was 39 years (range: 22-70 years. Twenty-seven of the thirty-two patients (84.3% had the dominant side fractured. We had eight cases of C2 type; five cases of C1 and A2 type; four cases of B2 type; three cases each of B3, B1, and A1 type; and one case of A3 type of fracture. The mean surgical time was 91.5 minutes (range: 70-120 minutes and mean radiation exposure was 160.3 seconds (range: 100-220 seconds. The mean radiological fracture union time was 12.9 weeks (range: 10-20 weeks. Shoulder function was excellent in 27 cases (84.3% and good in remaining 5 cases (15.6% on the UCLA score. Elbow function was excellent in 26 cases (81.2%, good in 5 cases (15.6%, and fair in 1 case (3.1% who had an associated olecranon fracture that was fixed by tension band wire in the same sitting. Conclusion: MIPO of

  3. Dual small fragment plating improves screw-to-screw load sharing for mid-diaphyseal humeral fracture fixation: a finite element study.

    Science.gov (United States)

    Kosmopoulos, Victor; Luedke, Colten; Nana, Arvind D

    2015-01-01

    A smaller humerus in some patients makes the use of a large fragment fixation plate difficult. Dual small fragment plate constructs have been suggested as an alternative. This study compares the biomechanical performance of three single and one dual plate construct for mid-diaphyseal humeral fracture fixation. Five humeral shaft finite element models (1 intact and 4 fixation) were loaded in torsion, compression, posterior-anterior (PA) bending, and lateral-medial (LM) bending. A comminuted fracture was simulated by a 1-cm gap. Fracture fixation was modelled by: (A) 4.5-mm 9-hole large fragment plate (wide), (B) 4.5-mm 9-hole large fragment plate (narrow), (C) 3.5-mm 9-hole small fragment plate, and (D) one 3.5-mm 9-hole small fragment plate and one 3.5-mm 7-hole small fragment plate. Model A showed the best outcomes in torsion and PA bending, whereas Model D outperformed the others in compression and LM bending. Stress concentrations were located near and around the unused screw holes for each of the single plate models and at the neck of the screws just below the plates for all the models studied. Other than in PA bending, Model D showed the best overall screw-to-screw load sharing characteristics. The results support using a dual small fragment locking plate construct as an alternative in cases where crutch weight-bearing (compression) tolerance may be important and where anatomy limits the size of the humerus bone segment available for large fragment plate fixation.

  4. Humeral Shaft Fracture: Intramedullary Nailing.

    Science.gov (United States)

    Konda, Sanjit R; Saleh, Hesham; Fisher, Nina; Egol, Kenneth A

    2017-08-01

    This video demonstrates the technique of intramedullary nailing for a humeral shaft fracture. The patient is a 30-year-old man who sustained a gunshot wound to his right arm. The patient was indicated for humeral nailing given the comminuted nature of the diaphysis and to allow for minimal skin incisions. Other relative indications include soft-tissue compromise about the arm precluding a large surgical exposure. This video presents a case of a comminuted humeral shaft fracture treated with an intramedullary nail. Anatomic reduction and stable fixation was obtained with this technique. This case demonstrates a soft-tissue sparing technique of humeral shaft fixation using a humeral intramedullary nail. The technique is easy to perform and has significant benefits in minimizing surgical exposure, decreasing operative time, and decreasing blood loss. In the correct clinical setting, humeral nailing provides an expeditious form of fixation that restores length, alignment, and rotation of the fracture humeral diaphysis.

  5. Two types of external fixators to correct humeral fracture in domestic pigeons

    International Nuclear Information System (INIS)

    Dalmolin, F.; Schossler, J.E.; Bertoletti, B.; Vasconcelos, A.; Muller, D.; Schossler, D.R.; Gomes, K.

    2007-01-01

    This paper was aimed at evaluating two changes in the external fixators for osteosynthesis of the humeral fracture that induce the correction of the humeral fracture in pigeons. The reduction of diaphyseal fracture was made with an intramedulary pin associated to another perpendicular one inserted into the distal segment (Group A - GA); in the Group B (GB) an additional pin was used in the proximal fragment. All the pigeons were evaluated clinically and radiographically up to 60 days, except for four of each group which were submitted to euthanasia at 15, 22, 29 and 36 days for the macro and microscope exams. The flight test was successful in all pigeons. The bone calus was radiografically visible only in the GA; the mean time and the standard deviation for flight was 32.25 ± 6.5 days for the GA and 39.8 ± 3.83 for the GB. The mean time and standard deviation for fracture healing was 36 ± 0 days in the GA and 34 ± 3.4 in the GB. The two types of external fixator evaluated were efficient to stabilized the fracture site allowing complete consolidation and return to function. The use of the external fixator with two perpendicular pins provides more stability at the fracture site although it is necessary more time for the surgery procedure [pt

  6. Diaphyseal long bone nonunions - types, aetiology, economics, and treatment recommendations.

    Science.gov (United States)

    Rupp, Markus; Biehl, Christoph; Budak, Matthäus; Thormann, Ulrich; Heiss, Christian; Alt, Volker

    2018-02-01

    The intention of the current article is to review the epidemiology with related socioeconomic costs, pathophysiology, and treatment options for diaphyseal long bone delayed unions and nonunions. Diaphyseal nonunions in the tibia and in the femur are estimated to occur 4.6-8% after modern intramedullary nailing of closed fractures with an even much higher risk in open fractures. There is a high socioeconomic burden for long bone nonunions mainly driven by indirect costs, such as productivity losses due to long treatment duration. The classic classification of Weber and Cech of the 1970s is based on the underlying biological aspect of the nonunion differentiating between "vital" (hypertrophic) and "avital" (hypo-/atrophic) nonunions, and can still be considered to represent the basis for basic evaluation of nonunions. The "diamond concept" units biomechanical and biological aspects and provides the pre-requisites for successful bone healing in nonunions. For humeral diaphyseal shaft nonunions, excellent results for augmentation plating were reported. In atrophic humeral shaft nonunions, compression plating with stimulation of bone healing by bone grafting or BMPs seem to be the best option. For femoral and tibial diaphyseal shaft fractures, dynamization of the nail is an atraumatic, effective, and cheap surgical possibility to achieve bony consolidation, particularly in delayed nonunions before 24 weeks after initial surgery. In established hypertrophic nonunions in the tibia and femur, biomechanical stability should be addressed by augmentation plating or exchange nailing. Hypotrophic or atrophic nonunions require additional biological stimulation of bone healing for augmentation plating.

  7. Prosthetic replacement for proximal humeral fractures.

    Science.gov (United States)

    Kontakis, George; Tosounidis, Theodoros; Galanakis, Ioannis; Megas, Panagiotis

    2008-12-01

    The ideal management of complex proximal humeral fractures continues to be debatable. Evolution of proximal humeral fracture management, during the past decade, led to the implementation of many innovations in surgical treatment. Even though the pendulum of treatment seems to swing towards new trends such as locked plating, hemiarthroplasty remains a valid and reliable option that serves the patient's needs well. Hemiarthroplasty is indicated for complex proximal humeral fractures in elderly patients with poor bone stock and when internal fixation is difficult or unreliable. Hemiarthroplasty provides a better result when it is performed early post-injury. Stem height, retroversion and tuberosity positioning are technical aspects of utmost importance. Additionally reverse total shoulder arthroplasty is an alternative new modality that can be used as a primary solution in selected patients with proximal humeral fracture treatment. Failed hemiarthroplasty and fracture sequelae can be successfully managed with reverse total shoulder arthroplasty. Individual decision-making and tailored treatment that takes into consideration the personality of the fracture and the patient's characteristics should be used.

  8. Ipsilateral humeral neck and shaft fractures

    Directory of Open Access Journals (Sweden)

    Zhu Bin

    2017-01-01

    Full Text Available Background/Aim. Fractures of the proximal humerus or shaft are common, however, ipsilateral neck and shaft humerus fracture is a rare phenomenon. This combination injury is challenging for orthopaedic surgeons because of its complex treatment options at present. The purpose of this study was to review a series of ipsilateral humeral neck and shaft fractures to study the fracture pattern, complications and treatment outcomes of each treatment options used. Methods. A total of six patients (four female and two male with the average age of 42.8 years (range: 36–49 years was collected and reviewed retrospectively. Two of them were treated with double plates and four with antegrade intramedullary nail. According to the Neer’s classification, all proximal fractures were two-part surgical neck fractures. All humeral shaft fractures were located at the middle of one third. Five fractures were simple transverse (A3, one fragmented wedge fracture (B3. One patient had associated radial nerve palsy. Results. All surgical neck fractures except one united uneventfully in the average time span of 8.7 weeks. Four humeral shaft fractures healed in near anatomic alignment. The remaining two patients had the nonunion with no radiological signs of fracture healing. The average University of California, Los Angeles End-Results (UCLA score was 23.1. On the contrary, the average American Shoulder and Elbow Surgeon's (ASES score was 73.3. The patients treated with antegrade intramedullary nails presented 70.5 points. The ASES scores were 79 in the double plates group. Conclusions. Ipsilateral humeral shaft and neck fracture is extremely rare. Both antegrade intramedullar nailing and double plates result in healing of fractures. However the risk of complication is lower in the double plating group.

  9. Medial calcar of proximal humeral fracture as landmark in restoration of humeral length in case of hemiarthroplasty

    Czech Academy of Sciences Publication Activity Database

    Hromádka, R.; Kuběna, Aleš Antonín; Šmíd, Martin; Popelka, S.

    2014-01-01

    Roč. 35, č. 5 (2014), s. 473-479 ISSN 0930-1038 Institutional support: RVO:67985556 Keywords : Fracture of proximal humerus * Calcar of humeral fracture * Reconstruction of proximal humerus * Reconstruction of humeral length * Shoulder arthroplasty * Shoulder hemiarthroplasty Subject RIV: FJ - Surgery incl. Transplants Impact factor: 1.047, year: 2014 http://library.utia.cas.cz/separaty/2013/E/smid-medial calcar of proximal humeral fracture as landmark in restoration of humeral length in case of hemiarthroplasty.pdf

  10. Drifting Diaphyses: Asymmetry in Diametric Growth and Adaptation Along the Humeral and Femoral Length.

    Science.gov (United States)

    Maggiano, Isabel S; Maggiano, Corey M; Tiesler, Vera G; Chi-Keb, Julio R; Stout, Sam D

    2015-10-01

    This study quantifies regional histomorphological variation along the human humeral and femoral diaphysis in order to gain information on diaphyseal growth and modeling drift patterns. Three thin sections at 40, 50, and 60% bone length were prepared from a modern Mexican skeletal sample with known age and sex to give a longitudinal perspective on the drifting cortex (12 adults and juveniles total, 7 male and 5 female). Point-count techniques were applied across eight cross-sectional regions of interest using the starburst sampling pattern to quantify percent periosteal and endosteal primary lamellar bone at each diaphyseal level. The results of this study show a posterio-medial drift pattern in the humerus with a posterior rotational trend along the diaphysis. In the femur, we observed a consistent lateral to anteriolateral drift and an increase in primary lamellar bone area of both, periosteal and endosteal origin, towards the distal part of the diaphysis. These observations characterize drifting diaphyses in greater detail, raising important questions about how to resolve microscopic and macroscopic cross-sectional analysis towards a more complete understanding of bone growth and mechanical adaptation. Accounting for modeling drift has the potential to positively impact age and physical activity estimation, and explain some of the significant regional variation in bone histomorphology seen within (and between) bone cross-sections due to differing ages of tissue formation. More study is necessary, however, to discern between possible drift scenarios and characterize populational variation. © 2015 Wiley Periodicals, Inc.

  11. New classification of proximal humeral fractures

    Energy Technology Data Exchange (ETDEWEB)

    Seemann, W R; Rupp, H G; Siebler, G

    1986-08-01

    Neer's classification of humeral fractures was proved on 657 patients. This classification enables the radiologist to estimate the risk of avascular necrosis of the head of the humerus. The problematic group is that of four part lesions, which has a 19% incidence of humeral head necrosis. Since in this group minimal osteosynthesis produces better functional results than extensive osteosynthesis, a detailed pre-operative radiological description of the fracture type is necessary in order to spare the patient from extensive surgery which could have unsatisfactory results.

  12. MONOLATERAL LOW-INVASIVE TREATMENT OF HUMERAL SHAFT FRACTURE IN CHILDREN

    Directory of Open Access Journals (Sweden)

    V. P. Kuzmin

    2012-01-01

    Full Text Available Humeral fractures in children are from 4 up to 10% of the general number of child fractures. Recently the trend is marked to expansion of indications to operative treatment despite of mainly conservative treatment of humeral shaft fractures. The experience of humeral shaft fractures operative treatment with use of Ender nails was analyzed. 8 humeral bones were treated with use of 2 nails, 15 humeral bones - with use of 1 nail only. The good and excellent results were received in both groups of patients. At the same time group with monolateral osteosynthesis (with 1 nail had statistically significant (p<0,01 decreasing of surgery time (average difference 16 min, and also it had statistically significant (p <0,001 decreasing of X-ray exposition time (average difference 23 sec in comparison with group where the osteosynthesis was done with use of 2 nails. The results received in study show necessity of the further work for this direction.

  13. Forearm diaphyseal fractures in the adolescent population: treatment and management.

    Science.gov (United States)

    Truntzer, Jeremy; Vopat, Matthew L; Kane, Patrick M; Christino, Melissa A; Katarincic, Julia; Vopat, Bryan G

    2015-02-01

    Pediatric both-bone diaphyseal forearm fractures are commonly treated in a variety of clinical settings. Most often, closed reduction followed by immobilization leads to satisfactory results. However, in the adolescent population (10-16 years of age), forearm fractures are more challenging due to less remodeling potential. The purpose of this review was to provide an overview of the anatomy, biomechanics, and treatment options relevant to adolescent patients. A systematic review of peer-reviewed publications and abstracts related to the treatment for pediatric both-bone diaphyseal forearm fractures in adolescents was carried out. Forearm fractures in the pediatric population are most common following indirect blows to the forearm. When treating these fractures using closed reduction, it is important to recognize the muscular attachments of the forearm. In roughly 70-90% of cases, closed reduction leads to adequate alignment. In all cases, return to function is the primary goal; however, exact alignment parameters remain controversial. In the adolescent population, surgical treatment has risen substantially in the last few decades. Intramedullary nailing and open reduction using plate fixation are the two most common operative techniques. Unfortunately, recent results have shown that nonunion, malunion, and overall complication rates are higher in older pediatric patients. Moreover, no consensus exists regarding one technique over another. Both-bone diaphyseal fractures in the adolescent population present unique challenges regarding optimal treatment, especially when considering surgical intervention. Further research is necessary to better understand indications for specific surgical treatment.

  14. Treatment of humeral shaft fractures with antegrade intramedullary locking nail.

    Science.gov (United States)

    Tsourvakas, Stefanos; Alexandropoulos, Christos; Papachristos, Ioannis; Tsakoumis, Grigorios; Ameridis, Nikolaos

    2011-12-01

    Antegrade interlocked humeral nailing for stabilization of humeral fractures was introduced many years ago, and studies on this method in the orthopedic literature have shown mixed results. The purpose of this investigation was to document the clinical outcome and complications associated with the use of an antegrade intramedullary nail (T2, Stryker) for the humeral fractures. Between 2005 and 2008, 52 fractures of the humeral shaft were treated operatively with this intramedullary nail in our department. Eight patients were polytraumatized, and four patients had an open fracture. The mean age of patients was 51.7 years. Forty-eight patients had an adequate duration of clinical follow-up (a mean of 18 months) for analysis. Complications were recorded, and the time to union was measured. Shoulder and elbow functions were assessed using the Constant Score and the Morrey Score, respectively. Forty-six fractures healed, with a mean time to clinical union of 10.3 weeks. Two patients developed pseudarthroses. There were four adverse events: two proximal screws backed out, one superficial infection at the insertion point, and one fracture at the distal end of the nail. Ninety-one percentage of patients had an excellent or good shoulder function. Five further operations were necessary: two for treatment of pseudarthroses, two for removal the backed out proximal screws, and one wound debridement for superficial infection. Antegrade humeral nailing is a valid therapeutic option for stabilization of humeral shaft fractures. By strictly adhering to the operation technique, the number and the severity of complications can be reduced. When good fracture alignment and stability are obtained, uneventful bone healing with good functional results is the rule.

  15. Trends in epidemiology and patho-anatomical pattern of proximal humeral fractures

    DEFF Research Database (Denmark)

    Bahrs, Christian; Stojicevic, Tanja; Tanja, Stojicevic

    2014-01-01

    PURPOSE: Proximal humeral fractures are common and frequently associated with osteoporosis. Little is known about the association between the patho-anatomical fracture pattern of proximal humeral fractures and patient characteristics. The purpose of this six year longitudinal registry analysis...... of proximal humeral fractures was to study overall numbers, certain predefined pathoanatomical patterns and distribution compared with specific patient characteristics. METHODS: Data of patients treated between 2006 and 2011 in a country hospital that provides care >95 % of the city's hospitalised patients...... with fractures was retrospectively reviewed. Data were analysed according to patient characteristics of age, gender, comorbidity, accompanying injuries and radiological analysis of pathoanatomical fracture patterns based on Neer and Arbeitsgemeinschaft für Osteosynthesefragen (AO) classification. RESULTS: Eight...

  16. Less invasive plate osteosynthesis in humeral shaft fractures.

    Science.gov (United States)

    Apivatthakakul, Theerachai; Phornphutkul, Chanakarn; Laohapoonrungsee, Anupong; Sirirungruangsarn, Yuddhasert

    2009-12-01

    Stable internal fixation of the humeral shaft by less invasive percutaneous plate insertion using two separate (proximal and distal) incisions, indirect reduction by closed manipulation and fixation to preserve the soft tissue and blood supply at the fracture zone. Early mobilization of the shoulder and elbow to ensure a good functional outcome. Humeral shaft fractures (classified according to AO classification as: 12-A, B, C). Humeral shaft fractures extending to the proximal or distal shaft, small or deformed medullary canal or open growth plate. Humeral shaft fractures with primary radial nerve palsy. Proximal humeral shaft fractures extending to the humeral head. Distal humeral fractures extending to the elbow joint. Two incisions proximal and distal to the fracture zone are used. A 3-cm proximal incision lies between the lateral border of the proximal part of the biceps and the medial border of the deltoid. Distally, a 3-cm incision is made along the lateral border of the biceps. The interval between biceps and brachialis is identified. The biceps is retracted medially to expose the musculocutaneous nerve. The brachialis muscle has dual innervation, the medial half being innervated by the musculocutaneous nerve and the lateral half by the radial nerve. The brachialis is split longitudinally at its midline. The musculocutaneous nerve is retracted along with the medial half of the brachialis, while the lateral half of the brachialis serves as a cushion to protect the radial nerve. A deep subbrachial tunnel is created from the distal to the proximal incision. The selected plate is tied with a suture to a hole at the tip of the tunneling instrument for pulling the plate back along the prepared track. The plate is aligned in the correct position on the anterior surface of the humerus. Traction is applied and the fracture reduced to restore alignment by image intensifier, followed by plate fixation with at least two bicortical locking screws or three bicortical

  17. Radial and humeral fractures as predictors of subsequent hip, radial or humeral fractures in women, and their seasonal variation

    DEFF Research Database (Denmark)

    Lauritzen, J B; Schwarz, Peter; McNair, P

    1993-01-01

    Hip fractures are common in elderly women, and early risk assessment of future hip fractures is relevant in relation to prevention. We studied the predictive value of radial and humeral fractures in women. The influence of weather conditions on the risk was also studied. Women aged 20-99 years...

  18. Dynamic osteosynthesis by modified Kuntscher nail for the treatment of tibial diaphyseal fractures.

    Science.gov (United States)

    Gadegone, Wasudeo M; Salphale, Yogesh S

    2009-04-01

    We evaluated a series of diaphyseal fractures of the tibia using low-cost, Indian-made modified Kuntscher nail (Daga nail) with the provision of distal locking screw for the management of the tibial diaphyseal fractures. One hundred and fifty one consecutive patients with diaphyseal fractures of tibia with 151 fractures who were treated by Daga nail were enrolled. One of the patients who had died because of cancer, and the two patients who were lost to follow-up at 3 months were excluded from the study.Therefore data of 148 patients with one hundred and fortyeight fractures is described. One hundred twenty closed fractures, 20 open Grade I fractures, and eight open Grade II fractures as per Gustilo and Anderson classification were included in this study. One hundred fourteen men and 34 women, with a mean age of 38.4 years, were studied. The result were analysed for Surgical time, duration of hospitalisation, union time, union rate, complication rate, functional recovery and crutch walking time. The fractures were followed at least until the time of solid union. The follow-up period averaged 15 months (range, 6-26 months). Union occurred in 140 cases (94.6%). The mean time to union was 13 weeks for closed fractures,17.8 weeks for Grade I open fractures, and 21.6 weeks for Grade II open fractures. Compartment syndrome occurred in two patients. Superficial infection occurred in five cases of Grade I and II compound fractures. Three closed fractures and one case of Grade I compound fracture required bone grafting for delayed union. Two cases of Grade II compound fracture with nonunion required revision surgery and bone grafting. Twelve cases resulted in acceptable malalignment due to operative technical error. In four cases, the distal screw breakage was seen, but none of these complications interfered with fracture healing. Recovery of joint motion was essentially normal in those patients without knee or ankle injury. Unreamed distally locked dynamic tibial nailing

  19. Dynamic osteosynthesis by modified Kuntscher nail for the treatment of tibial diaphyseal fractures

    Directory of Open Access Journals (Sweden)

    Gadegone Wasudeo

    2009-01-01

    Full Text Available Background: We evaluated a series of diaphyseal fractures of the tibia using low-cost, Indian-made modified Kuntscher nail (Daga nail with the provision of distal locking screw for the management of the tibial diaphyseal fractures. Materials and Methods: One hundred and fifty one consecutive patients with diaphyseal fractures of tibia with 151 fractures who were treated by Daga nail were enrolled. One of the patients who had died because of cancer, and the two patients who were lost to follow-up at 3 months were excluded from the study.Therefore data of 148 patients with one hundred and fortyeight fractures is described. One hundred twenty closed fractures, 20 open Grade I fractures, and eight open Grade II fractures as per Gustilo and Anderson classification were included in this study. One hundred fourteen men and 34 women, with a mean age of 38.4 years, were studied. The result were analysed for Surgical time, duration of hospitalisation, union time, union rate, complication rate, functional recovery and crutch walking time. The fractures were followed at least until the time of solid union. Results: The follow-up period averaged 15 months (range, 6-26 months. Union occurred in 140 cases (94.6%. The mean time to union was 13 weeks for closed fractures,17.8 weeks for Grade I open fractures, and 21.6 weeks for Grade II open fractures. Compartment syndrome occurred in two patients. Superficial infection occurred in five cases of Grade I and II compound fractures. Three closed fractures and one case of Grade I compound fracture required bone grafting for delayed union. Two cases of Grade II compound fracture with nonunion required revision surgery and bone grafting. Twelve cases resulted in acceptable malalignment due to operative technical error. In four cases, the distal screw breakage was seen, but none of these complications interfered with fracture healing. Recovery of joint motion was essentially normal in those patients without knee or

  20. Paediatric diaphyseal femur fracture treated with intramedullary titanium elastic nail system

    Directory of Open Access Journals (Sweden)

    Shrawan Kumar Thapa

    2015-11-01

    Full Text Available noBackground & Objectives: Over the few years there has been a marked increase in the use of intramedullary fixation in the management of fracture of shaft of femur in children. The goals should be to stabilize the fracture, to control length and alignment, to promote bone healing and to minimize the morbidity and complications for the child. In this prospective study we intend to evaluate the functional and radiological outcome of diaphyseal fracture of shaft of femur treated with elastic intramedullary nail.Materials & Methods: All 56 patients with diaphyseal fracture shaft of femur were treated with titanium elastic nail and followed for period of 32 weeks.Results: The In this study, outcome was assessed by using Flynn’s criteria of titanium flexible nail outcome score and we found excellent result in 49 cases, satisfactory in six cases and poor in one case. We faced one major complication in form of implant failure and six minor complications inform of superficial wound infection.Conclusion: Elastic intramedullary nail used in treatment of diaphyseal fracture shaft of femur yield excellent functional and radiological outcome. It is easy and simple procedure has low rate of complication. It is physeal-protective, cost effective, does not involve heavy instrumentation and can be performed in small set up. It has minimal risk of infection and no risk of injury to the neurovascular structure.JCMS Nepal. 2015; 11(2:20-22

  1. Humeral repair in birds by guided tissue regeneration and external and internal associated fixation techniques

    International Nuclear Information System (INIS)

    Delogu, M.

    1993-01-01

    Ten pigeons (Columba livia domestic form) with humeral diaphyseal fracture were treated with external and internal fixation techniques (Boston technique and intamedullary pin). Longitudinal space was intentionally left between fracture surfaces during osteosynthesis. This space was filled with bovine lyophilized collagen, set around an intramedullary pin, in five samples. Ossification process was checked by radiography every seven days. Results show the utility of this technique in pneumatic bird bones. In fact, shortening control and callus formation facility were observed [it

  2. The value of different imaging methods on classification in displaced proximal humeral fractures

    International Nuclear Information System (INIS)

    Cai Jingyu; Zhu Qingsheng

    2004-01-01

    Objective: To investigate the influence of common X-ray, two-dimensional computed tomography (2D-CT), spiral computed tomography (SCT), and three-dimensional (3-D) reconstruction on the classification in displaced proximal humeral fractures. Methods: Three groups were divided on the basis of various imaging methods, including group A (common X-ray), group B (common X-ray and 2D-CT), and group C (3-D reconstruction of SCT and 2D-SCT). 46 cases of displaced proximal humeral fractures were classified with Neer system. The true rate of fracture classification by use of three methods was compared with each other, and clinical significance of SCT and 3-D reconstruction was evaluated. Results: Based on operation, 46 cases of displaced proximal humeral fractures in group A included 26 cases of Neer two-part fractures, 13 cases of three-part fractures, and 7 cases of four-part fractures. The true cases of common X-ray were 22 in Neer two-part fractures and 8 in three and four-part fractures, there was significant difference between Neer two-part fractures and Neer three and four-part fractures (P<0.05); 18 cases of proximal humeral fractures in group B included 3 cases of Neer two-part fractures, 9 cases of three-part fractures, and 6 cases of four-part fractures. The true cases of common X-ray and 2D-CT were 7 in Neer three and four-part fractures. 10 cases of proximal humeral fractures in group C included 1 case of Neer two-part fracture, 5 cases of three-part fractures, and 4 cases of four-part fractures. The true cases of 3-D reconstruction, MPR of SCT, and 2D-SCT were 8 in Neer three and four-part fractures. With regard to the true cases of the classification in Neer three and four-part fractures, there was significant difference in three groups and between group A and group C (P<0.05). All SCT and 3-D reconstruction played an important role in the treatment of proximal humeral fractures. Conclusion: Series of good quality X-ray examinations were the first imaging

  3. Fishtail deformity - a delayed complication of distal humeral fractures in children

    Energy Technology Data Exchange (ETDEWEB)

    Narayanan, Srikala [Massachusetts General Hospital, Department of Radiology, Division of Pediatric Imaging, Boston, MA (United States); University of Pittsburgh Medical Center, Department of Radiology, Pittsburgh, PA (United States); Shailam, Randheer; Nimkin, Katherine [Massachusetts General Hospital, Department of Radiology, Division of Pediatric Imaging, Boston, MA (United States); Grottkau, Brian E. [Massachusetts General Hospital, Department of Orthopaedics, Pediatric Orthopaedics, Boston, MA (United States)

    2015-06-15

    Concavity in the central portion of the distal humerus is referred to as fishtail deformity. This entity is a rare complication of distal humeral fractures in children. The purpose of this study is to describe imaging features of post-traumatic fishtail deformity and discuss the pathophysiology. We conducted a retrospective analysis of seven cases of fishtail deformity after distal humeral fractures. Seven children ages 7-14 years (five boys, two girls) presented with elbow pain and history of distal humeral fracture. Four of the seven children had limited range of motion. Five children had prior grade 3 supracondylar fracture treated with closed reduction and percutaneous pinning. One child had a medial condylar fracture and another had a lateral condylar fracture; both had been treated with conservative casting. All children had radiographs, five had CT and three had MRI. All children had a concave central defect in the distal humerus. Other imaging features included joint space narrowing with osteophytes and subchondral cystic changes in four children, synovitis in one, hypertrophy or subluxation of the radial head in three and proximal migration of the ulna in two. Fishtail deformity of the distal humerus is a rare complication of distal humeral fractures in children. This entity is infrequently reported in the radiology literature. Awareness of the classic imaging features can result in earlier diagnosis and appropriate treatment. (orig.)

  4. Fishtail deformity - a delayed complication of distal humeral fractures in children

    International Nuclear Information System (INIS)

    Narayanan, Srikala; Shailam, Randheer; Nimkin, Katherine; Grottkau, Brian E.

    2015-01-01

    Concavity in the central portion of the distal humerus is referred to as fishtail deformity. This entity is a rare complication of distal humeral fractures in children. The purpose of this study is to describe imaging features of post-traumatic fishtail deformity and discuss the pathophysiology. We conducted a retrospective analysis of seven cases of fishtail deformity after distal humeral fractures. Seven children ages 7-14 years (five boys, two girls) presented with elbow pain and history of distal humeral fracture. Four of the seven children had limited range of motion. Five children had prior grade 3 supracondylar fracture treated with closed reduction and percutaneous pinning. One child had a medial condylar fracture and another had a lateral condylar fracture; both had been treated with conservative casting. All children had radiographs, five had CT and three had MRI. All children had a concave central defect in the distal humerus. Other imaging features included joint space narrowing with osteophytes and subchondral cystic changes in four children, synovitis in one, hypertrophy or subluxation of the radial head in three and proximal migration of the ulna in two. Fishtail deformity of the distal humerus is a rare complication of distal humeral fractures in children. This entity is infrequently reported in the radiology literature. Awareness of the classic imaging features can result in earlier diagnosis and appropriate treatment. (orig.)

  5. Feasibility of a reduction protocol in the emergency department for diaphyseal forearm fractures in children.

    Science.gov (United States)

    Pesenti, S; Litzelmann, E; Kahil, M; Mallet, C; Jehanno, P; Mercier, J-C; Ilharreborde, B; Mazda, K

    2015-09-01

    Diaphyseal forearm fractures are very common pediatric traumas. At present, distal radius metaphyseal fractures are often successfully treated with closed reduction by emergency physicians. However, the management of diaphyseal fractures remains controversial. The purpose of this study was to analyze the results of diaphyseal forearm fractures in the emergency department (ED) in children. In a prospective 2-year-study, all closed diaphyseal forearm fractures in patients under 15, with an angle of >15° and treated by closed reduction in the ED were included. Fractures with overlapping fragments were excluded. Reduction was performed by an emergency physician, with a standardized analgesic protocol (painkillers and nitrous oxide). Clinical tolerance was checked within the first 24hours, and the radiographic stability of reduction was assessed at days 8 and 15. Initial and final follow-up radiographs were analyzed. Elbow and wrist range of motion was assessed at the final follow-up. Sixty patients (41 boys and 19 girls) were included. Mean age was 5.2 years old (±3). At initial evaluation, the maximum angle was 30° (±11.3). After reduction, the maximum angle was significantly reduced (30° vs. 5°, P<0.001). Mean immobilization in a cast was 11.7 weeks (±2). There were no cast related complications in any of these children. There was no surgery for secondary displacement. Full range of motion was obtained in all patients at the final follow-up. The outcome of conservative treatment of closed diaphyseal forearm fractures, without overlapping fragments was excellent. However, reduction is usually performed in the operating room by orthopedic surgeons under general anesthesia and requires hospitalization, which is very expensive. The results of this study show that high quality care may be obtained in the ED by a trained and experienced team. These results are similar to those for distal metaphyseal fractures, which could extend the indications for reduction in the

  6. Preexisting lesions associated with complete diaphyseal fractures of the third metacarpal bone in 12 Thoroughbred racehorses.

    Science.gov (United States)

    Gray, Sarah N; Spriet, Mathieu; Garcia, Tanya C; Uzal, Francisco A; Stover, Susan M

    2017-07-01

    We characterized features of complete diaphyseal fractures of third metacarpal bones in Thoroughbred racehorses. Given that stress fractures are known to occur in the third metacarpal bone, an additional aim was to determine if complete fractures are associated with signs of a preexisting incomplete stress fracture. Bilateral metacarpi from 12 Thoroughbred racehorses euthanized because of complete unilateral metacarpal diaphyseal fracture were examined visually and radiographically. Open, comminuted, transverse or short oblique fractures occurred in the middle of the diaphysis or supracondylar region. Periosteal surface discoloration and bone callus formation contiguous with the fracture line were present in fractured bones. All contralateral intact metacarpi had gross anatomic lesions, and 10 had radiographic abnormalities similar to those observed on fractured metacarpi. Catastrophic metacarpal fractures occurred in racehorses with bilateral evidence of preexisting bone injury.

  7. O emprego de hastes intramedulares bloqueadas no tratamento das fraturas diafisárias do úmero Use of blocked intramedullary shaft for the treatment of humeral diaphyseal fractures

    Directory of Open Access Journals (Sweden)

    Fernando Baldy dos Reis

    2005-01-01

    Full Text Available Estudamos os resultados clínicos e radiográficos de 31 pacientes portadores de fraturas diafisárias do úmero que foram operados com hastes intramedulares. Destes quatro apresentaram fraturas no local da inserção da haste e foram tratados com outro método. Dos 27 pacientes restantes o índice de consolidação foi de 96,1 % e que durou em média de 63,4 dias. Cinco queixaram-se de dor no ombro e em apenas um apresentou limitação da abdução. Paralisia temporária do nervo radial foi constatada em dois pacientes e pseudartrose em um que após 5 meses da cirurgia foi submetido a nova intervenção cirúrgica com o emprego de placa e enxerto ósseo autólogo. Concluímos que embora o emprego de hastes intramedulares bloqueadas apresentou alto índice de a via de acesso retrógrada pode levar a fraturas no seu ponto de entrada e via anterógrada com violação do manguito rotador pode gerar dores no ombro.Clinical and radiographic outcomes of 31 patients with humeral diaphyseal fractures submitted to surgery with intramedullary shafts were studied. From these, four patients presented fractures at the shaft insertion site and were treated using a different method. From the 27 patients left, the healing rate was 96.1%, with an average duration of 63.4 days. Five of them complained of pain in the shoulder and only one presented abduction limitation. Temporary palsy of the radial nerve was found in two patients and pseudoarthrosis in one of them, who was submitted to a new surgical intervention with plate and autologous bone graft, after 5 months. It was concluded that, although blocked intramedullary shafts presents a high incidence of the retrograde access port leading to fractures in its insertion site and the anterograde port causing pain in the shoulder.

  8. Ilizarov′s method for treatment of nonunion of diaphyseal fractures of the humerus

    Directory of Open Access Journals (Sweden)

    Kiran Manish

    2010-01-01

    Full Text Available Background: Nonunion in diaphyseal fractures of the humerus can be treated by various modalities like plating and bone grafting, exchange nailing, fibular strut grafting and Ilizarov′s method of ring fixation. To achieve union in infected nonunion in which multiple surgeries have already been done is further challenging. We conducted a prospective study wherein the outcome of the treatment of nonunion of diaphyseal fractures of the humerus by Ilizarov′s method was analyzed. Materials and Methods: Nineteen patients with diaphyseal nonunion of the humerus were treated by Ilizarov′s external fixator. These included nonunion after plating (n=11, intramedullary nailing (n=1 or conservative methods (n=7. In post-surgical infected nonunion (n=6, the implants were removed, debridement done, bone fragments were docked followed by application of ring fixator and compression. In aseptic nonunion (n=13, distraction for three weeks followed by compression was the protocol. Early shoulder and elbow physiotherapy was instituted. The apparatus was removed after clinical and radiological union and the results were assessed for bone healing and functional status. Results: Fracture union was achieved in all the 19 cases. Pin site infection was seen in 2 cases (10.52%. The bone healing results were excellent in eighteen cases (94.73% and good in one case (5.26%.The functional results were found to be excellent in fourteen cases (73.68%, good in four (21.05% and fair in one case (5.26%. Conclusion: Ilizarov′s method is an excellent option for treatment of septic and aseptic non union of diaphyseal fractures of the humerus as it addresses all the problems associated with non union of the humerus like infection, deformity and joint stiffness.

  9. Investigating the form-function interface in African apes: Relationships between principal moments of area and positional behaviors in femoral and humeral diaphyses.

    Science.gov (United States)

    Carlson, Kristian J

    2005-07-01

    Investigations of cross-sectional geometry in nonhuman primate limb bones typically attribute shape ratios to qualitative behavioral characterizations, e.g., leaper, slow climber, brachiator, or terrestrial vs. arboreal quadruped. Quantitative positional behavioral data, however, have yet to be used in a rigorous evaluation of such shape-behavior connections. African apes represent an ideal population for such an investigation because their relatedness minimizes phylogenetic inertia, they exhibit diverse behavioral repertoires, and their locomotor behaviors are known from multiple studies. Cross-sectional data from femoral and humeral diaphyses were collected for 222 wild-shot specimens, encompassing Pan paniscus and all commonly recognized African ape subspecies. Digital representations of diaphyseal cross sections were acquired via computed tomography at three locations per diaphysis. Locomotor behaviors were pooled broadly into arboreal and terrestrial categories, then partitioned into quadrupedal walking, quadrumanous climbing, scrambling, and suspensory categories. Sex-specific taxonomic differences in ratios of principal moments of area (PMA) were statistically significant more often in the femoral diaphysis than the humeral diaphysis. While it appears difficult to relate a measure of shape (e.g., PMA ratio) to individual locomotor modes, general locomotor differences (e.g., percentage arboreal vs. terrestrial locomotion) are discerned more easily. As percentage of arboreal locomotion for a group increases, average cross sections appear more circular. Associations between PMA ratio and specific locomotor behaviors are less straightforward. Individual behaviors that integrate eccentric limb positions (e.g., arboreal scrambling) may not engender more circular cross sections than behaviors that incorporate repetitive sagittal movements (e.g., quadrupedal walking) in a straightforward manner. (c) 2004 Wiley-Liss, Inc

  10. Treatment of Middle Third Humeral Shaft Fractures with Anteromedial Plate Osteosynthesis through an Anterolateral Approach.

    Science.gov (United States)

    Kumar, B S; Soraganvi, P; Satyarup, D

    2016-03-01

    Background: Treatment of humeral shaft fractures has been a subject of debate for many decades. Even though a large majority of humeral shaft fractures can be treated by non operative methods, few conditions like open fractures, polytrauma, ipsilateral humeral shaft and forearm fractures require surgical intervention. The goal of treatment of humeral shaft fractures is to establish union with an acceptable humeral alignment and to restore the patient to pre-injury level of function. The objective was to assess the incidence of radial nerve palsy, non-union and mean time required for in anteromedial plate osteosynthesis with anterolateral approach and also to measure the functional outcome of this procedure. Method: A prospective study was conducted in the Department of Orthopaedics, PESIMSR, Kuppam, Andhra Pradesh, from August 2012 to August 2015 with a total of 54 patients who were operated with anteromedial plate osteosynthesis were included in the study. Rodriguez- Merchan criteria was used to grade the functional outcome. Results: Of the 54 patients, 28 (58.85%) were in the age group of 30-40 years. The most common fracture pattern identified was A3 type (48.14%).The mean (± SD) duration of surgery for anteromedial humeral plating was 53 ± 5.00 minutes. The time taken for the fracture to unite was less than 16 weeks in the majority or 50 patients (92.59%). Four (7.40%) patients had delayed union. There was no incidence of iatrogenic radial nerve palsy. Rodriguez - Merchan criteria showed that 37(68.51%) of the patients had good and 12 (22.22%) had excellent functional outcome.

  11. Defining the Lower Limit of a "Critical Bone Defect" in Open Diaphyseal Tibial Fractures.

    Science.gov (United States)

    Haines, Nikkole M; Lack, William D; Seymour, Rachel B; Bosse, Michael J

    2016-05-01

    To determine healing outcomes of open diaphyseal tibial shaft fractures treated with reamed intramedullary nailing (IMN) with a bone gap of 10-50 mm on ≥50% of the cortical circumference and to better define a "critical bone defect" based on healing outcome. Retrospective cohort study. Forty patients, age 18-65, with open diaphyseal tibial fractures with a bone gap of 10-50 mm on ≥50% of the circumference as measured on standard anteroposterior and lateral postoperative radiographs treated with IMN. IMN of an open diaphyseal tibial fracture with a bone gap. Level-1 trauma center. Healing outcomes, union or nonunion. Forty patients were analyzed. Twenty-one (52.5%) went on to nonunion and nineteen (47.5%) achieved union. Radiographic apparent bone gap (RABG) and infection were the only 2 covariates predicting nonunion outcome (P = 0.046 for infection). The RABG was determined by measuring the bone gap on each cortex and averaging over 4 cortices. Fractures achieving union had a RABG of 12 ± 1 mm versus 20 ± 2 mm in those going on to nonunion (P gaps have a higher probability of nonunion. Research investigating interventions for RABGs should use a predictive threshold for defining a critical bone defect that is associated with greater than 50% risk of nonunion without supplementary treatment. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  12. Minimally invasive plating osteosynthesis for mid-distal third humeral shaft fractures.

    Science.gov (United States)

    Lian, Kejian; Wang, Lei; Lin, Dasheng; Chen, Zhiwen

    2013-08-01

    Mid-distal third humeral shaft fractures can be effectively treated with minimally invasive plating osteosynthesis and intramedullary nailing (IMN). However, these 2 treatments have not been adequately compared. Forty-seven patients (47 fractures) with mid-distal third humeral shaft fractures were randomly allocated to undergo either minimally invasive plating osteosynthesis (n=24) or IMN (n=23). The 2 groups were similar in terms of fracture patterns, fracture location, age, and associated injuries. Intraoperative measurements included blood loss and operative time. Clinical outcome measurements included fracture healing, radial nerve recovery, and elbow and shoulder discomfort. Radiographic measurements included fracture alignment, time to healing, delayed union, and nonunion. Functional outcome was satisfactory in both groups. Mean American Shoulder and Elbow Surgeons score and Mayo score were both better for the minimally invasive plating osteosynthesis group than for the IMN group (98.2 vs 97.6, respectively, and 93.5 vs 94.1, respectively; Pshaft fractures. Minimally invasive plating osteosynthesis is more suitable for complex fractures, especially for radial protection and motion recovery of adjacent joints, compared with IMN for simple fractures. Copyright 2013, SLACK Incorporated.

  13. Minimally invasive plate osteosynthesis of humeral shaft fractures: a technique to aid fracture reduction and minimize complications.

    Science.gov (United States)

    Shin, Sang-Jin; Sohn, Hoon-Sang; Do, Nam-Hoon

    2012-10-01

    To introduce a modified operative technique for minimally invasive plate osteosynthesis (MIPO) for acute displaced humeral shaft fractures and to evaluate the clinical and radiological outcomes. : Prospective clinical series study. University hospital. Twenty-one patients with acute displaced humeral shaft fractures were treated by MIPO with a modified fracture reduction technique. A narrow 4.5/5.0-mm locking compression plate was applied to the anterior aspect of the humerus. Fracture reduction and manipulation were performed using a plate and drill bits. The operating time, time to union, humeral alignment, and functional outcome of the shoulder and elbow joints were evaluated using the University of California Los Angeles shoulder score and Mayo elbow performance score. No patient experienced a neurological complication. Bony union was obtained in 20/21 patients at a mean 17.5 weeks postoperatively. Eighteen patients had excellent and 3 patients had good results in the University of California Los Angeles score. The average Mayo elbow performance score was 97.5. Two patients were converted to an open reduction during operation due to a failure of MIPO. There was 1 nonunion and 1 malunion in this series. Although the MIPO technique for humeral shaft fractures is technically demanding, satisfactory clinical outcomes in terms of bony union and shoulder and elbow function can be obtained using the modified fracture reduction method. Potential postoperative complications, such as malreduction and nonunion, must be considered. Appropriate surgical indications, a thorough understanding of the neurovascular anatomy and skillful surgical technique, are needed to reduce potential complications.

  14. Treatment of Middle Third Humeral Shaft Fractures with Anteromedial Plate Osteosynthesis through an Anterolateral Approach

    Directory of Open Access Journals (Sweden)

    Kumar BS

    2016-03-01

    Full Text Available Background: Treatment of humeral shaft fractures has been a subject of debate for many decades. Even though a large majority of humeral shaft fractures can be treated by non operative methods, few conditions like open fractures, polytrauma, ipsilateral humeral shaft and forearm fractures require surgical intervention. The goal of treatment of humeral shaft fractures is to establish union with an acceptable humeral alignment and to restore the patient to pre-injury level of function. The objective was to assess the incidence of radial nerve palsy, non-union and mean time required for in anteromedial plate osteosynthesis with anterolateral approach and also to measure the functional outcome of this procedure. Method: A prospective study was conducted in the Department of Orthopaedics, PESIMSR, Kuppam, Andhra Pradesh, from August 2012 to August 2015 with a total of 54 patients who were operated with anteromedial plate osteosynthesis were included in the study. RodriguezMerchan criteria was used to grade the functional outcome. Results: Of the 54 patients, 28 (58.85% were in the age group of 30-40 years. The most common fracture pattern identified was A3 type (48.14%.The mean (+ SD duration of surgery for anteromedial humeral plating was 53 ± 5.00 minutes. The time taken for the fracture to unite was less than 16 weeks in the majority or 50 patients (92.59%. Four (7.40% patients had delayed union. There was no incidence of iatrogenic radial nerve palsy. Rodriguez – Merchan criteria showed that 37(68.51% of the patients had good and 12 (22.22% had excellent functional outcome.

  15. Total elbow arthroplasty for the treatment of distal humeral fractures.

    Science.gov (United States)

    Gallucci, G L; Larrondo Calderón, W; Boretto, J G; Castellaro Lantermo, J A; Terán, J; de Carli, P

    2016-01-01

    To report the clinical-functional outcomes of the treatment of humeral distal fractures with a total elbow prosthesis. This retrospective study was performed in two surgical centres. A total of 23patients were included, with a mean age of 79years, and of which 21 were women. The inclusion criteria were: patients with humeral distal fractures, operated on using a Coonrad-Morrey prosthesis, and with a follow-up of more than one year. According to AO classification, 15fractures were type C3, 7 C2 and 1 A2. All patients were operated on without de-insertion of the extensor mechanism. The mean follow-up was 40 months. Flexor-extension was 123-17°, with a total mobility arc of 106° (80% of the contralateral side). Pain, according to a visual analogue scale was 1. The Mayo Elbow Performance Index (MEPI) was 83 points. Excellent results were obtained in 8 patients, good in 13, medium in 1, and poor in 1. The mean DASH (disability) score was 24 points. Treatment of humeral distal fractures with total elbow arthroplasty could be a good treatment option, but indications must be limited to patients with complex fractures, poor bone quality, with osteoporosis and low functional demands. In younger patients, the use is limited to serious cases where there is no other treatment option. Level of Evidence IV. Copyright © 2016 SECOT. Published by Elsevier Espana. All rights reserved.

  16. "Effect of Hydroxyapatite to Load Failure Value in Rat with Diaphyseal Femur Fracture"

    OpenAIRE

    Rinartha, Adi Surya; Rahyussalim, Rahyussalim

    2011-01-01

    Introduction. Calcium hydroxyapatite are non organic compound of the bone formed the fracture healing. In fracture healing, the parts of the compounds make up unordinary scaffold and producing an incredible amount of me- senchymal stem cell under bearing of the scaffold. This study is aimed to determine the effect of hydroxyapatite administration to load failure value in mice with diaphyseal femur fracture. Materials and methods. Research was done using Sprague Dawley rat undergone ...

  17. Systematic review of spica casting for the treatment of paediatric diaphyseal femur fractures.

    Science.gov (United States)

    Tisherman, R T; Hoellwarth, J S; Mendelson, S A

    2018-04-01

    Paediatric femur fractures are commonly encountered and often successfully managed with spica casting. Despite spica casting's long history there is little formal guidance for optimal outcomes and no consolidation of existing literature. The purpose of this study is to review the available literature regarding the use of spica casting for the management of paediatric diaphyseal femur fractures. The PubMed database was queried for all research articles including the phrase "spica". A total of 788 abstracts were reviewed for relevance to the current study. Data was extracted from all available research studies which specified tolerance for fracture angulation or shortening in the cast. Additionally, all articles describing alternative materials, methods for spica application, and complications of spica casting were reviewed. In all, 106 articles were found relevant to the management of diaphyseal femur fractures in the paediatric population. The aggregated, accepted fracture shortening decreased from 16 mm to 18 mm before age ten years to 12 mm to 14 mm after puberty. Aggregated, accepted angulation decreased from 14° to 16° varus/valgus and 18° to 22° pro/recurvatum before age two years, to 6° to 8° and 10° to 12° by puberty, respectively. The overall reported complication rate was 19.6%, with the most common complication being skin compromise in 8.2% of patients, followed by unacceptable angulation at the fracture site in 4.2% of patients and excessive limb shortening in 1.9% of patients. This article reviews the available spica casting literature and compiles the available data. Spica casting offers a safe, effective means for definitive management of paediatric diaphyseal femur fractures. Future research identifying the rate and pattern of remodelling as it relates to angulation and shortening at various patient ages, particularly beyond the aforementioned norms, would be valuable to identify true biological tolerances versus accepted expert opinion

  18. Critical differences between subtrochanteric and diaphyseal atypical femoral fractures: analyses of 51 cases at a single institution in Korean population.

    Science.gov (United States)

    Cho, Yoon-Je; Kang, Kyung-Chung; Chun, Young-Soo; Rhyu, Kee Hyung; Kim, Sang-Jun; Jang, Tae-Su

    2018-05-03

    There still remains controversy on the pathomechanism of atypical femoral fracture (AFF). The angle of lateral bowing and bone mineral density showed significant differences between subtrochanteric and diaphyseal atypical fracture groups. In addition to the use of bisphosphonate, mechanical factors might play important roles in the occurrence of AFFs. Although AFF could be divided into subtrochanteric and diaphyseal fracture according to the location of fractures, there is a lack of evidence regarding differences between two fractures and etiology of the occurrence. The aim of study is to determine differences between atypical subtrochanteric and diaphyseal fracture in Korean population. Between February 2010 and March 2015, 51 AFFs in 40 patients were included in this study. Their medical records were retrospectively reviewed. The AFF patients satisfied all the diagnostic criteria of the 2014 revised edition of the ASMBR. To analyze the differences according to the location of fracture, the AFFs were divided into subtrochanteric (n = 16) and diaphyseal (n = 35) fracture groups. The following factors were compared between two groups: patients' demographics, underlying diseases, laboratory findings (serum-25(OH) VitD3, osteocalcin, c-telopeptide, ALP, Ca, and P), bone mineral density (BMD), duration of bisphosphonate (BP) usage, and lateral bowing of the femur at time of the fracture. All AFFs happened in female patients (mean age, 73.8 years) who have received bisphosphonate treatments except three patients. The mean duration of bisphosphonate usage was 95.3 months. Between the two groups, demographic data (age, height, weight, and BMI), underlying diseases, laboratory findings, hip BMD, and duration of BP treatment were comparable to each other (p > 0.05). However, the subtrochanteric fracture group showed higher FNSBA (femoral neck shaft bowing angle, p group. Angle of lateral bowing (FNSBA) and spine BMD showed significant differences between

  19. High risk for revision after shoulder arthroplasty for failed osteosynthesis of proximal humeral fractures

    DEFF Research Database (Denmark)

    Kristensen, Marc Randall; Rasmussen, Jeppe Vejlgaard; Elmengaard, Brian

    2018-01-01

    Background and purpose - It is unclear whether previous osteosynthesis is a risk factor for inferior outcome following shoulder arthroplasty for a proximal humeral fracture. We used data from the Danish Shoulder Arthroplasty Registry (DSR) to examine this question. Patients and methods - All 285...... patients treated with a shoulder arthroplasty after failed osteosynthesis of a proximal humeral fracture reported to DSR from 2006 to 2013 were included. Each case was matched with 2 controls (570) treated with a primary shoulder arthroplasty for an acute proximal humeral fracture. Patient reported outcome...... for a shoulder arthroplasty after failed osteosynthesis was 2 with a primary arthroplasty for fracture as reference. In a separate analysis of patients treated by locking plate the mean WOOS was 46 (24), with a relative risk of revision at 1.5 with a primary arthroplasty as reference. Interpretation - Compared...

  20. Treatment for proximal humeral fractures with percutaneous plating: our first results.

    Science.gov (United States)

    Imarisio, D; Trecci, A; Sabatini, L; Scagnelli, R

    2013-06-01

    Proximal humeral fractures are common lesions; there is no generally accepted strategy about the treatment for displaced and unstable two- to four-part fractures. We have nowadays many different surgical solutions, ranging from percutaneous pinning to shoulder arthroplasty. Percutaneous plating can be a good solution to treat some of these fractures using a minimally invasive technique and performing stable fixation that can allow early mobilization. Purpose of this paper is to evaluate the results of our first cases of percutaneous plating in proximal humeral fractures in order to assess the theoretical advantages and the incidence of possible complications. From June 2009 to February 2012, we treated 29 proximal humeral fractures with a percutaneous plating (NCB-PH plate) through an anterolateral deltoid split. For each patient, we evaluated the clinical outcome according to Constant score and the radiographic results, paying attention to fracture healing, loss of reduction, hardware complications, and head necrosis. The clinical evaluation gave a mean Constant score value of 79 points. Comparing each value to the unaffected shoulder, we could find these results: 7 excellent, 10 good, 8 fair, and 4 poor. No axillary nerve lesions were clinically detected. The radiographic evaluation showed a complete bone healing in all cases within the first 3 months. No head necrosis was detected, as well as screws loosening. In two cases, the X-ray at 2 months revealed a little loss of reduction in varus. Two patients had an anterior pain; in one of these two cases, the plate was removed. In our series, we had no cases of head necrosis, screws cutout, fracture collapse, hardware mobilization, and we think this could be the real advantage of the percutaneous technique compared to the open one, thanks to the reduced biological damage. We had some poor results, related more to patient's age than to other factors. The safety of the technique for the axillary nerve is

  1. Humeral fractures due to low-energy trauma: an epidemiological survey in patients referred to a large emergency department in Northern Italy.

    Science.gov (United States)

    Pedrazzoni, M; Abbate, B; Verzicco, I; Pedrazzini, A; Benatti, M; Cervellin, G

    2015-01-01

    This survey describes the epidemiology of approximately 1800 low-energy humeral fractures seen in a large emergency department in Northern Italy over 7 years (2007-2013), highlighting the differences from previous Italian studies. The purpose of this study was to determine the incidence of humeral fractures due to low-energy trauma in patients 40 years of age or older referred to a large Emergency Department (Parma, Northern Italy) in a 7-year period (2007-2013). All humeral fractures referred to the emergency department of the Academic Hospital of Parma (the main hospital in the province with a catchment area of approximately 345,000) were retrieved from the hospital database using both ICD-9CM codes and text strings. The diagnosis of humeral fracture due to low-energy trauma was confirmed by medical records and X-ray reports, after exclusion of injuries due to a clear-cut high-energy trauma or cancer. The query identified 1843 humeral fractures (1809 first fractures), with a clear predominance in women (78 %). Fractures of the proximal humerus represented the large majority of humeral fractures (more than 85 %), with an incidence progressively increasing with age (more than 60-fold in women and 20-fold in men). Simultaneous fractures (hip in particular) were frequent especially after 85 years of age (1 out of 8 cases). When compared to other Italian studies, the incidence of humeral fractures was significantly lower than that derived from discharge data corrected for hospitalization rate (standardized rate ratio 0.74; p energy humeral fractures in Italy. Our results partly differ from previous Italian studies based on indirect estimations.

  2. Subtrochanteric and diaphyseal femur fractures in patients treated with alendronate: a register-based national cohort study

    DEFF Research Database (Denmark)

    Abrahamsen, Bo; Eiken, Pia; Eastell, Richard

    2009-01-01

    Alendronate (aln) is a potent bisphosphonate with a prolonged duration of action. Recent reports have found long-term aln use to be common in patients with subtrochanteric or proximal diaphyseal femur fracture, raising concerns that these fractures could be a consequence of excessive suppression...

  3. Operative treatment of lateral humeral condyle fractures in children.

    Science.gov (United States)

    Wirmer, Johannes; Kruppa, Christian; Fitze, Guido

    2012-08-01

    The operative treatment of lateral humeral condyle fractures in children remains controversial. The result of incorrectly treated fractures may lead to complications such as pseudoarthrosis and severe deformity, with considerable functional and cosmetic restrictions. The aim of this study was to determine whether operative treatment of lateral humeral condyle fractures in children using Screw-wires (Orthofix GmbH, Ottobrunn, Germany) has any advantage over treatment with Kirschner wires ("K-wires") (aap-Implantate AG, Berlin, Germany). These results were then compared with operative treatment using lag-screw osteosynthesis. We treated surgically 76 cases of fracture of the lateral humeral condyle in children at the Department of Pediatric Surgery in Dresden between 1989 to 2002 and 2004 to 2008, from which 42 were available for follow-up examination. Within this group, there were seven children that were followed-up twice (in 1996 to 2002). Of these, 21 patients were treated with Screw-wires, and another 21 had K-wires inserted. The results were evaluated according to the Dhillon criteria. Only seven patients (17%) had a fair result in the overall grading according to the Dhillon criteria, four after K-wire and three after Screw-wire osteosyntheses. The remaining patients scored good to excellent results. There were no pseudoarthroses. Six patients (14%) had a varisation in the carrying angle between 10 and 16 degrees (three each procedure), and 15 patients (36%) had no difference in the carrying angle at all. Of these 15 patients, 10 were treated with Screw-wire osteosynthesis. Only one patient (2.4%) had a deficit of more than 10 degrees in elbow joint flexion, while only two (4.8%, one each procedure) had a deficit of more than 10 degrees in elbow joint extension, compared with the uninjured arm. Our results demonstrate that the employment of Screw-wire osteosynthesis is superior to the use of K-wires concerning the carrying angle while scoring alike on the

  4. Hemiarthroplasty for proximal humeral fracture: restoration of the Gothic arch.

    Science.gov (United States)

    Krishnan, Sumant G; Bennion, Phillip W; Reineck, John R; Burkhead, Wayne Z

    2008-10-01

    Proximal humerus fractures are the most common fractures of the shoulder girdle, and initial management of these injuries often determines final outcome. When arthroplasty is used to manage proximal humeral fractures, surgery remains technically demanding, and outcomes have been unpredictable. Recent advances in both technique and prosthetic implants have led to more successful and reproducible results. Key technical points include restoration of the Gothic arch, anatomic tuberosity reconstruction, and minimal soft tissue dissection.

  5. Postoperative malrotation of humeral shaft fracture after plating compared with intramedullary nailing.

    Science.gov (United States)

    Li, Ying; Wang, Cheng; Wang, Manyi; Huang, Lei; Huang, Qiang

    2011-09-01

    We supposed difference of rotation alignment of postoperative humeral shaft fracutres between open reduction and internal fixation (ORIF) and intramedullay nailing (IMN) could be identified and the difference might influence the involved shoulder. This study evaluated and compared the extent of malrotation and shoulder function after humeral shaft fractures treated operatively with IMN or ORIF. Fifty humeral shaft fractures were randomly allocated into 2 groups. Group I underwent antegrade IMN and group II underwent ORIF. Malrotation was measured postoperatively by computed tomography scan (CT). Fracture union and functional outcomes were recorded at 12 months. The final analysis comprised 45 patients. Group I had lower functional scores than group II (P shaft fracture. The study can provide baseline data for larger series and longer follow-up periods. Patients who underwent IMN had lower functional scores and a decreased range of motion postoperatively and also had a greater degree of malrotation than the ORIF group, which had none. The degree of malrotation correlated with a decreased range of motion and may possibly be a reason for degenerative arthritis at long-term follow-up. Copyright © 2011 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  6. Interventions for treating proximal humeral fractures in adults

    DEFF Research Database (Denmark)

    Handoll, Helen H G; Brorson, Stig

    2015-01-01

    supervised exercise in a swimming pool plus home exercise.Eight trials, involving 567 older participants, evaluated surgical intervention for displaced fractures. There was high quality evidence of no clinically important difference in patient-reported shoulder and upper-limb function at one- or two......BACKGROUND: Fracture of the proximal humerus, often termed shoulder fracture, is a common injury in older people. The management of these fractures varies widely. This is an update of a Cochrane Review first published in 2001 and last updated in 2012. OBJECTIVES: To assess the effects (benefits...... and harms) of treatment and rehabilitation interventions for proximal humeral fractures in adults. SEARCH METHODS: We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register, the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, and other databases, conference...

  7. An inconvenient truth: treatment of displaced paediatric supracondylar humeral fractures.

    LENUS (Irish Health Repository)

    Donnelly, M

    2012-06-01

    The need for emergent management of displaced paediatric supracondylar humeral fractures is being questioned in the literature. Open reduction rates of up to 46% have been reported in the non-emergent management of these injuries. At our institution these fractures are managed as operative emergencies by senior personnel. To examine the ongoing need for this policy we reviewed our results. All patients managed over a five year period with Gartland type IIB or III paeditric supracondylar humeral fractures were identified and a comprehensive chart and radiographic review undertaken. The mean time from injury to fracture reduction and stabilization was 6.6 h. Consultants performed or supervised 90% of cases. Open reduction was necessary in 5% of cases. Complications included a perioperative nerve injury rate of 6% and a superficial pin site infection rate of 3%. This study suggests that, despite the challenge to trauma on-call rostering, the emergency management of these injuries is advantageous to patients in units of our size. Based on the data presented here we continue our practice of emergent management. We suggest that units of a similar size to our own would show a benefit from an analogous policy albeit an inconvenient truth.

  8. Osteosynthesis with long volar locking plates for meta- physeal-diaphyseal fractures of the distal radius

    Directory of Open Access Journals (Sweden)

    Gogna Paritosh

    2013-12-01

    Full Text Available 【Abstract】Objective: Metaphyseal-diaphyseal fractures of the distal radius are a major treatment dilemma and orthopaedic surgeons have to pay due consideration to restoration of anatomy of distal radius together with ro- tation of the radial shaft and maintenance of radial bow and interosseous space. We performed this study to evaluate the clinic-radiological outcome of metaphyseal-diaphyseal fractures of the distal radius treated with long volar locking plates. Methods: This prospective study involved 27 pa- tients (22 males and 5 females with metaphyseal-diaphy- seal fracture of the distal radius. Their mean age was (30.12± 11.48 years (range 19-52 years and the follow-up was 26.8 months (range 22-34 months. All patients underwent open reduction and internal fixation with a long volar locking plate. According to AO/OTA classification, there were 7 type A3, 13 type C2 and 7 type C3 fractures. Subjective assessment was done based on the disabilities of the arm, shoulder and hand (DASH questionnaire. Functional evaluation was done by measuring grip strength and range of motion around the wrist and the radiological determinants included radial angle, radial length, volar angle and ulnar variance. The final as- sessment was done according to Gartland and Werley scor- ing system. Results: Postoperative radiological parameters were well maintained throughout the trial, and there was signifi- cant improvement in the functional parameters from 6 weeks to final follow-up. The average DASH scores improved from 37.5 at 6 weeks to 4.2 at final follow-up. Final assessment using Gartland and Werley scoring system revealed 66.67% (n=18 excellent and 33.33% (n=9 good results. There was one case of superficial infection which responded to antibi- otics and another carpel tunnel syndrome which was ma- naged conservatively. Conclusion: Volar locking plate fixation for metaphy- seal-diaphyseal fractures of distal radius is associated with excellent to good

  9. Translation between the Neer- and the AO/OTA-classification for proximal humeral fractures

    DEFF Research Database (Denmark)

    Brorson, Stig; Eckardt, Henrik; Audigé, Laurent

    2013-01-01

    The reporting and interpretation of data from clinical trials of proximal humeral fractures are hampered by the use of two partly incommensurable fracture classification systems: the Neer classification and the AO/OTA classification. It remains difficult to interpret and generalize results...

  10. Outcome of humeral shaft fractures treated by functional cast brace

    Directory of Open Access Journals (Sweden)

    Jitendra Nath Pal

    2015-01-01

    Conclusion: Modified functional cast brace is one of the options in treatment for humeral shaft fractures as it can be applied on the 1 st day of the presentation in most of the situations. Simple objective scoring system was useful particularly in uneducated patients.

  11. Flexible intramedullary nailing for femoral diaphyseal fractures in children

    Directory of Open Access Journals (Sweden)

    Rojan Tamrakar

    2017-12-01

    Full Text Available Background & Objectives: Although various treatment options are available for the treatment of femoral diaphyesal fractures in children, the titanium flexible nailing has gained popularity because it is safe, easy procedure with rapid recovery and high success rate. The aim of this study was to evaluate the outcome of titanium elastic nails in treating paediatric femoral diaphyesal fractures at Patan Hospital.Materials & Methods: There were 35 cases which were all fixed with titanium flexible intramedullary nail under image intensifier at the Patan hospital from January 2013 and December 2015. Patients were evaluated in follow-ups to observe the alignment of fracture, infection, delayed union, nonunion, limb length discrepancy, implant failure, range of movement of hip and knee joints, and time to unite the fracture. The final results were evaluated using criteria of titanium elastic nail (TEN outcome score described by Flynn et al.Results: The mean age of the patients was 8.51 years. Among 35 patients (22 boys and 13 girls, there were 19 mid-shaft fractures, nine proximal third fractures and seven distal third fractures. Fracture patterns were transverse (22, oblique (10, spiral (2, and comminuted (2. The mean time for fracture union was 8.17 weeks radiologically whereas 9.83 weeks clinically. According to TEN outcome score, excellent and good results were in 28 cases (80% and seven cases (20% respectively.Conclusion: Flexible titanium nailing is a safe and satisfactory treatment for diaphyseal femoral fractures in children, because it provides rapid recovery, short rehabilitation and immobilization as well as very high union rate with few complications.

  12. Titanium elastic nailing in pediatric femoral diaphyseal fractures

    Directory of Open Access Journals (Sweden)

    Singh Roop

    2006-01-01

    Full Text Available Background: The need for operative fixation of pediatric femoral fractures is increasingly being recognised in the present decade. The conventional traction and casting method for management of pediatric femoral fractures is giving way for the operative stabilisation of the fracture. Methods : Thirty five pediatric patients in age group 6-14 years with diaphyseal femoral fractures were stabilised with two titanium nails. Patients were followed up clinically and radiologically for two years. The final results were evaluated using the criteria of Flynn et al. Technical problems and complications associated with the procedure were also analysed. Results : Overall results observed were excellent in 25, satisfactory in 8 and poor in 2 patients. Hospital time averaged 12.30 days in the series. All the fractures healed with an average time to union of 9.6 (6-14.4 weeks. Return to school was early with an average of 7.8 weeks. The soft tissue discomfort near the knee produced by the nails ends was the most common problem encountered. Shortening was observed in three cases and restriction of knee flexion in 5 patients. There was no delayed union, infection or refractures. Per operative technical problems included failure of closed reduction in 2 cases and cork screwing of nails in one case. Conclusion : We believe that with proper operative technique and aftercare TENs may prove to be an ideal implant for pediatric femoral fracture fixation. The most of the complication associated with the procedure are infact features of inexact technique and can be eliminated by strictly adhering to the basic principles and technical aspects.

  13. Biomechanical study in vitro on the use of self-designed external fixator in diaphyseal III metacarpal fractures in horses.

    Science.gov (United States)

    Turek, B; Potyński, A; Wajler, C; Szara, T; Czopowicz, M; Drewnowska, O

    2015-01-01

    Diaphyseal fractures of the III metacarpal bone represent 22% of all fractures of the long bones in horses. Treatment of such cases is difficult. The most popular solution used in these types of fractures is two plates applied directly to the bone surface, but they are not applicable on contaminated and infected fractures. External fixators are quite commonly used in human medicine, although in veterinary practice there is no typical stabilizer designed for the treatment of diaphyseal fractures of the III metacarpal bone so far. In this study, an external semicircular fixator of our own design was used and in vitro strength tests were conducted to determine the maximum force which would lead to the destruction of non-fractured bone and fractured bone treated with the stabilizer. On the basis of the strength tests, we can conclude that the stabilizer can be strong enough to allow the horse to stand up after surgery. It also has many favorable features which make it easy to assemble and to take care of a wound, while being safe enough for the animal at the same time.

  14. Indications for computed tomography (CT-) diagnostics in proximal humeral fractures

    DEFF Research Database (Denmark)

    Bahrs, Christian; Rolauffs, Bernd; Südkamp, Norbert P

    2009-01-01

    diagnostics depending on the fractured parts. METHODS: In a prospective diagnostic study in two level 1 trauma centers, 44 patients with proximal humeral fractures were diagnosed with conventional X-rays (22 AP + axillary views, 22 AP + scapular Y-views) and CT (multi-planar reconstruction (MPR) and maximum...... diagnostic methods was assessed according to the number of fractured parts (Bonferroni-Holm adjustment). RESULTS: There was significantly more overlap of the fractured region on the scapular Y-views (mean 71.5%, range 45-90%) than on axillary views (mean 56.2%, range 10.5-100%). CT-diagnostics allowed...... a significantly better assessment of the relevant structures than conventional diagnostics (p diagnostics of the fracture...

  15. Who are we missing? Too few skeletal surveys for children with humeral and femoral fractures

    International Nuclear Information System (INIS)

    Shelmerdine, S.C.; Das, R.; Ingram, M.D.; Negus, S.

    2014-01-01

    Aim: To determine the potential shortfall in skeletal survey referral for children presenting with an acute non-supracondylar humeral or femoral fracture. Materials and methods: Plain radiograph reports were reviewed retrospectively using the radiology information system database over a 5 year study period (May 2008–2013) in children under 18 months of age who presented with an acute fracture. Subsequent skeletal survey referral was used as a surrogate marker for further investigation of child abuse. Application of robust meta-analysis derived probability data regarding likelihood of child abuse as a cause of non-supracondylar humeral or femoral fracture was applied. An estimation of the expected number of cases of abuse, with shortfall in skeletal survey referrals, was then calculated. Results: There were 288 fractures in 281 children. Three children presented with multiple fractures and were considered separately in the present data. The mean patient age was 10.5 months. Nine (3%) non-supracondylar humeral fractures were identified of which four cases may have been due to non-accidental injury (NAI). One (11%) of these patients was referred for a skeletal survey indicating a potential shortfall of three referrals. Twenty-five (9%) femoral fractures were identified of which 13 cases may have been due to NAI, with six (24%) referrals for skeletal surveys generated. This indicates a potential shortfall of seven referrals. Conclusion: The present study serves as a current analysis of practice within a tertiary paediatric referral centre. There appeared to be local under-investigation of NAI. Improved child protection education and awareness programmes have now been introduced. - Highlights: • Long bone fractures in non-ambulatory children carry high probability for child abuse. • Suspicion for child abuse should trigger a referral for a skeletal survey. • We examine the potential shortfall in skeletal survey referrals in such patients. • Only 11% and 24% of

  16. Outcome of intramedullary interlocking SIGN nail in tibial diaphyseal fracture

    International Nuclear Information System (INIS)

    Khan, I.; Javed, S.; Khan, G.N.; Aziz, A.

    2013-01-01

    Objective: To determine the outcome of intramedullary interlocking surgical implant generation network (SIGN) nail in diaphyseal tibial fractures in terms of union and failure of implant (breakage of nail or interlocking screws). Study Design: Case series. Place and Duration of Study: Orthopaedics and Spinal Surgery, Ghurki Trust Teaching Hospital, Lahore Medical and Dental College, Lahore, from September 2008 to August 2009. Methodology: Fifty patients aged 14 - 60 years, of either gender were included, who had closed and Gustilo type I and II open fractures reported in 2 weeks, whose closed reduction was not possible or was unsatisfactory and fracture was located 7 cm below knee joint to 7 cm above ankle joint. Fractures previously treated with external fixator, infected fractures and unfit patients were excluded. All fractures were fixed with intramedullary interlocking SIGN nail and were followed clinically and radiographically for union and for any implant failure. Results: Forty one (88%) patients had united fracture within 6 months, 5 (10%) patients had delayed union while 4 (8%) patients had non-union. Mean duration for achieving union was 163 + 30.6 days. Interlocking screws were broken in 2 patients while no nail was broken in any patient. Conclusion: Intramedullary interlocking nailing is an effective measure in treating closed and grade I and II open tibial fractures. It provides a high rate of union less complications and early return to function. (author)

  17. Outcome of intramedullary interlocking SIGN nail in tibial diaphyseal fracture.

    Science.gov (United States)

    Khan, Irfanullah; Javed, Shahzad; Khan, Gauhar Nawaz; Aziz, Amer

    2013-03-01

    To determine the outcome of intramedullary interlocking surgical implant generation network (SIGN) nail in diaphyseal tibial fractures in terms of union and failure of implant (breakage of nail or interlocking screws). Case series. Orthopaedics and Spinal Surgery, Ghurki Trust Teaching Hospital, Lahore Medical and Dental College, Lahore, from September 2008 to August 2009. Fifty patients aged 14 - 60 years, of either gender were included, who had closed and Gustilo type I and II open fractures reported in 2 weeks, whose closed reduction was not possible or was unsatisfactory and fracture was located 7 cm below knee joint to 7 cm above ankle joint. Fractures previously treated with external fixator, infected fractures and unfit patients were excluded. All fractures were fixed with intramedullary interlocking SIGN nail and were followed clinically and radiographically for union and for any implant failure. Forty one (88%) patients had united fracture within 6 months, 5 (10%) patients had delayed union while 4 (8%) patients had non-union. Mean duration for achieving union was 163 + 30.6 days. Interlocking screws were broken in 2 patients while no nail was broken in any patient. Intramedullary interlocking nailing is an effective measure in treating closed and grade I and II open tibial fractures. It provides a high rate of union less complications and early return to function.

  18. Pseudoarthrosis following proximal humeral fractures: A possible mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Rooney, P.J.; Cockshott, W.P.

    1986-01-01

    A small series of four patients with pseudarthrosis of the proximal humeral shaft is reported. These patients all had restricted movement of the shoulder joint prior to the trauma, three as a result of rheumatoid arthritis and one due a surgical fusion of the glenohumeral joint. It is suggested that pseudarthrosis is more likely under these circumstances and that pursuit of union of the fracture in such patients may not always be necessary.

  19. Radial nerve palsy in mid/distal humeral fractures: is early exploration effective?

    Science.gov (United States)

    Keighley, Geffrey; Hermans, Deborah; Lawton, Vidya; Duckworth, David

    2018-03-01

    Radial nerve palsies are a common complication with displaced distal humeral fractures. This case series examines the outcomes of early operative exploration and decompression of the nerve with fracture fixation with the view that this provides a solid construct for optimisation of nerve recovery. A total of 10 consecutive patients with a displaced distal humeral fracture and an acute radial nerve palsy were treated by the senior author by open reduction and internal fixation of the distal humerus and exploration and decompression of the radial nerve. Motor function and sensation of the radial nerve was assessed in the post-operative period every 2 months or until full recovery of the radial nerve function had occurred. All patients (100%) had recovery of motor and sensation function of their upper limb in the radial nerve distribution over a 12-month period. Recovery times ranged between 4 and 32 weeks, with the median time to recovery occurring at 26 weeks and the average time to full recovery being 22.9 weeks. Wrist extension recovered by an average of 3 months (range 2-26 weeks) and then finger extension started to recover 2-6 weeks after this. Disability of the arm, shoulder and hand scores ranged from 0 to 11.8 at greater than 1 year post-operatively. Our study demonstrated that early operative exploration of the radial nerve when performing an open stabilization of displaced distal humeral fractures resulted in a 100% recovery of the radial nerve. © 2017 Royal Australasian College of Surgeons.

  20. Intramedullary nail versus dynamic compression plate fixation in treating humeral shaft fractures: grading the evidence through a meta-analysis.

    Directory of Open Access Journals (Sweden)

    JianXiong Ma

    Full Text Available There is a debate regarding the choice of operative intervention in humeral shaft fractures that require surgical intervention. The choices for operative interventions include intramedullary nailing (IMN and dynamic compression plate (DCP. This meta-analysis was performed to compare fracture union, functional outcomes, and complication rates in patients treated with IMN or DCP for humeral shaft fractures and to develop GRADE (Grading of Recommendations, Assessment, Development, and Evaluation-based recommendations for using the procedures to treat humeral shaft fractures. A systematic search of all the studies published through December 2012 was conducted using the Medline, Embase, Sciencedirect, OVID and Cochrane Central databases. The randomized controlled trials (RCTs and quasi-RCTs that compared IMN with DCP in treating adult patients with humeral shaft fractures and provided data regarding the safety and clinical effects were identified. The demographic characteristics, adverse events and clinical outcomes were manually extracted from all of the selected studies. Ten studies that included a total of 448 patients met the inclusion criteria. The results of a meta-analysis indicated that both IMN and DCP can achieve similar fracture union with a similar incidence of radial nerve injury and infection. IMN was associated with an increased risk of shoulder impingement, more restriction of shoulder movement, an increased risk of intraoperative fracture comminution, a higher incidence of implant failure, and an increased risk of re-operation. The overall GRADE system evidence quality was very low, which reduces our confidence in the recommendations of this system. DCP may be superior to IMN in the treatment of humeral shaft fractures. Because of the low quality evidence currently available, high-quality RCTs are required.

  1. Shaft-Condylar Angle for surgical correction in neglected and displaced lateral humeral condyle fracture in children.

    Science.gov (United States)

    Mulpruek, Pornchai; Angsanuntsukh, Chanika; Woratanarat, Patarawan; Sa-Ngasoongsong, Paphon; Tawonsawatruk, Tulyapruek; Chanplakorn, Pongsthorn

    2015-09-01

    To assess the outcome after using the Shaft-Condylar angle (SCA) as intraoperative reference for sagittal plane correction in displaced lateral humeral condyle fractures in children presented 3-weeks after injury. Ten children, with delayed presentation of a displaced lateral humeral condyle fracture and undergoing surgery during 1999-2011, were reviewed. The goal was to obtain a smooth articular surface with an intraoperative SCA of nearly 40° and nearest-anatomical carrying angle. They were allocated into two groups according to the postoperative SCA [Good-reduction group (SCA=30-50°), and Bad-reduction group (SCA50°)] and the final outcomes were then compared. All fractures united without avascular necrosis. The Good-reduction group (n=7) showed a significant improvement in final range of motion and functional outcome compared to the Bad-reduction group (n=3) (p=0.02). However, there was no significant difference in pain, carrying angle and overall outcome between both groups. SCA is a possible intraoperative reference for sagittal alignment correction in late presented displaced lateral humeral condyle fractures.

  2. Treatment of humeral shaft fractures using antegrade nailing: functional outcome in the shoulder.

    Science.gov (United States)

    Patino, Juan Martin

    2015-08-01

    The purpose of this study was to evaluate shoulder outcomes and function after humeral shaft fractures treated with antegrade nailing. Thirty patients with acute humeral shaft fractures who underwent antegrade locked intramedullary nailing were retrospectively studied. Range of motion (ROM) of the affected shoulder was evaluated, comparing it with the nonaffected shoulder, radiologic position of the nails, complications, and need for a second surgery. The study enrolled 20 men and 10 women (average age, 41.9 years). The average follow-up was 35.8 months. The average shoulder elevation averaged 157°, internal rotation was variable (reaching the sacroiliac joint to T7), and external rotation averaged 75°. Elbow flexion-extension ROM averaged 133° (115°-145°). According to the Rodriguez-Merchan criteria, 12 patients achieved excellent results (40%), 7 good (20%), and 6 fair (23.3%); poor results were found in 5 cases (16.6%). Twelve patients achieved full mobility of the shoulder, whereas 18 had some loss of motion, with significant differences between the affected and nonaffected shoulders (P = .001). Decreased shoulder ROM is common after antegrade nailing of humeral shaft fractures. Avoidance of nail impingement can improve final outcomes. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  3. [Internal screwed plate for recent fractures of the humeral diaphysis in adults].

    Science.gov (United States)

    Dayez, J

    1999-06-01

    Can medial plating of the humerus, through an antero lateral approach, diminish incidence of iatrogenic radial palsies? We carried out a prospective study of medial plating of humeral shaft fractures through an antero lateral approach between 1988 and 1997. 41 fractures were fixed, 36 were followed up for a mean period of 5.8 years. The indications were multiple injuries (10), displaced fractures (23), and failure of conservative treatment (3). Road traffic accidents and sports injuries were the cause in 68 per cent of cases. Two fractures were open and in 9 cases there was a radial palsy. Bone graft was never used. The approach to the medial aspect of the humerus an antero lateral incision was the essential feature of the technique. After a slightly curved incision on the antero lateral aspect of the arm, the space between biceps and brachialis anterior was bluntly dissected. The assistant holded the elbow flexed in order to relax the biceps and rotated il laterally to expose the medial aspect of the bone. Splitting brachialis fibres longitudinally exposed the fracture site. It was easy to check if the radial nerve was trapped and, if not, the nerve seen during the operation. Postoperatively patients were given a simple sling and mobilised freely, including rotation. We had no intra-operative complications, no infections, no fixation failure, no post operative radial palsies and no non-unions. Results were excellent in 89 per cent of cases (full recovery of pain free range of movement). Four patient had a restriction of elbow movements of 10 degrees but without any discomfort. The mean time to union was 80 days. All radial nerve palsies recovered between 24 hours and 1 year. The plate was removed in 11 cases. Iatrogenic complications of humeral plating have led to the increased popularity of intramedullary nailing. Even if secondary radial palsies and non-unions have decreased, union of the humeral shafts is often difficult. Placing the plate into the medial

  4. Indications for computed tomography (CT-) diagnostics in proximal humeral fractures: a comparative study of plain radiography and computed tomography

    OpenAIRE

    Weise Kuno; Pereira Philippe L; Dietz Klaus; Eingartner Christoph; Schmal Hagen; Südkamp Norbert P; Rolauffs Bernd; Bahrs Christian; Lingenfelter Erich; Helwig Peter

    2009-01-01

    Abstract Background Precise indications for computed tomography (CT) in proximal humeral fractures are not established. The purpose of this study was a comparison of conventional radiographic views with different CT reconstructions with 2 D and 3 D imaging to establish indications for additional CT diagnostics depending on the fractured parts. Methods In a prospective diagnostic study in two level 1 trauma centers, 44 patients with proximal humeral fractures were diagnosed with conventional X...

  5. Interventions for treating proximal humeral fractures in adults.

    Science.gov (United States)

    Handoll, Helen H G; Brorson, Stig

    2015-11-11

    Fracture of the proximal humerus, often termed shoulder fracture, is a common injury in older people. The management of these fractures varies widely. This is an update of a Cochrane Review first published in 2001 and last updated in 2012. To assess the effects (benefits and harms) of treatment and rehabilitation interventions for proximal humeral fractures in adults. We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register, the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, and other databases, conference proceedings and bibliographies of trial reports. The full search ended in November 2014. We considered all randomised controlled trials (RCTs) and quasi-randomised controlled trials pertinent to the management of proximal humeral fractures in adults. Both review authors performed independent study selection, risk of bias assessment and data extraction. Only limited meta-analysis was performed. We included 31 heterogeneous RCTs (1941 participants). Most of the 18 separate treatment comparisons were tested by small single-centre trials. The main exception was the surgical versus non-surgical treatment comparison tested by eight trials. Except for a large multicentre trial, bias in these trials could not be ruled out. The quality of the evidence was either low or very low for all comparisons except the largest comparison.Nine trials evaluated non-surgical treatment in mainly minimally displaced fractures. Four trials compared early (usually one week) versus delayed (three or four weeks) mobilisation after fracture but only limited pooling was possible and most of the data were from one trial (86 participants). This found some evidence that early mobilisation resulted in better recovery and less pain in people with mainly minimally displaced fractures. There was evidence of little difference between the two groups in shoulder complications (2/127 early mobilisation versus 3/132 delayed mobilisation; 4 trials) and

  6. Clinic research on the treatment for humeral shaft fracture with minimal invasive plate osteosynthesis: a retrospective study of 128 cases.

    Science.gov (United States)

    Chen, H; Hu, X; Yang, G; Xiang, M

    2017-04-01

    Minimal invasive plate osteosynthesis (MIPO) is one of the most important techniques in the treatment for humeral shaft fractures. This study was performed to evaluate the efficacy of MIPO technique for the treatment for humeral shaft fractures. We retrospectively evaluated 128 cases with humeral shaft fractures that were treated with MIPO technique from March 2005 to August 2008. All the patients were followed up by routine radiological imaging and clinical examinations. Constant-Murley score and HSS elbow joint score were used to evaluate the treatment outcome. The average duration of the surgery was 60 min (range 40-95 min) without blood transfusion. All fractures healed without infection. All cases recovered carrying angle except four cases with 10°-15° cubitus varus. After the average follow-up of 23 (13-38) months, satisfactory function was achieved according to Constant-Murley score and HSS elbow joint score. Constant-Murley score was 80 on average (range 68-91). According to HSS elbow joint score, there were 123 cases of excellent clinical outcome and five cases of effective outcome. It seems to be a safe and effective method for managing humeral shaft fractures with MIPO technique.

  7. Application of 3D-printing technology in the treatment of humeral intercondylar fractures.

    Science.gov (United States)

    Zheng, W; Su, J; Cai, L; Lou, Y; Wang, J; Guo, X; Tang, J; Chen, H

    2018-02-01

    This study was aimed to compare conventional surgery and surgery assisted by 3D-printing technology in the treatment of humeral intercondylar fractures. In addition, we also investigated the effect of 3D-printing technology on the communication between doctors and patients. A total of 91 patients with humeral intercondylar fracture were enrolled in the study from March 2013 to August 2015. They were divided into two groups: 43 cases of 3D-printing group, 48 cases of conventional group. The individual models were used to simulate the surgical procedures and carry out the surgery according to plan. Operation duration, blood loss volume, fluoroscopy times and time to fracture union were recorded. The final functional outcomes, including the motion of the elbow, MEPS and DASH were also evaluated. Besides, we made a simple questionnaire to verify the effectiveness of the 3D-printed model for both doctors and patients. The operation duration, blood loss volume and fluoroscopy times for 3D-printing group was 76.6±7.9minutes, 231.1±18.1mL and 5.3±1.9 times, and for conventional group was 92.0±10.5minutes, 278.6±23.0mL and 8.7±2.7 times respectively. There was statistically significant difference between the conventional group and 3D-printing group (p3D-printing model. This study suggested the clinical feasibility of 3D-printing technology in treatment of humeral intercondylar fractures. Level II prospective randomized study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  8. Training improves agreement among doctors using the Neer system for proximal humeral fractures in a systematic review

    DEFF Research Database (Denmark)

    Brorson, Stig; Hróbjartsson, Asbjørn

    2008-01-01

    OBJECTIVE: To systematically review studies of observer agreement among doctors classifying proximal humeral fractures according to the Neer system. STUDY DESIGN AND SETTING: A systematic review. We searched for observational studies in which doctors classified proximal humeral fractures according......, and the methodological quality was assessed. RESULTS: We included 11 observational studies (88 observers and 468 cases). Mean kappa-values for interobserver agreement ranged from 0.17 to 0.52. Agreement did not improve through selection of experienced observers, advanced imaging modalities, or simplification...

  9. The management of humeral shaft fractures with associated radial nerve palsy: a review of 117 cases.

    Science.gov (United States)

    Bumbasirević, Marko; Lesić, Aleksandar; Bumbasirević, Vesna; Cobeljić, Goran; Milosević, Ivan; Atkinson, Henry Dushan E

    2010-04-01

    This single center retrospective study reviews the management and outcomes of 117 consecutive patients with humeral shaft fractures and associated radial nerve palsy (RNP) treated over a 20-year period (1986-2006). A total of 101 fractures were managed conservatively and 16 fractures underwent external fixation for poor bony alignment. Sixteen grade 1 and 2 open fractures underwent wound toileting alone. No patients underwent initial radial nerve exploration or opening of the fracture sites. All patients achieved clinical and radiological bony union at a mean of 8 weeks (range 7-12 weeks). There were no complications or pin tract infections in the operated patients. A total of 111 cases had initial spontaneous RNP recovery at a mean of 6 weeks (range 3-24 weeks) with full RNP recovery at a mean of 17 weeks (range 3-70 weeks) post-injury. Fourteen patients had no clinical/EMG signs of nerve activity at 12 weeks and 6 subsequently failed to regain any radial nerve recovery; 2 had late explorations and the lacerated nerves underwent sural nerve cable neurorraphy; and 4 patients underwent delayed tendon transposition 2-3 years after initial injury, with good/excellent functional outcomes. Humeral fractures with associated RNP may be treated expectantly. With low rates of humeral nonunion, 95% spontaneous nerve recovery in closed fractures and 94% in grade 1 and 2 open fractures, one has the opportunity of waiting. If at 10-12 weeks there are no clinical/EMG signs of recovery, then nerve exploration/secondary reconstruction is indicated. Late tendon transfers may also give good/excellent functional results.

  10. Skin puckering an uncommon sign of underlying humeral neck fracture: a case report.

    LENUS (Irish Health Repository)

    Davarinos, N

    2012-01-31

    Skin puckering is a sign that is well associated with certain fractures such as supracondylar humeral fractures in children. To our knowledge, there has been only one clinical report of skin puckering associated with fractured neck of humerus of an adult. This is a second such case of fractured proximal humerus in an adult presenting with skin puckering and the first from the Republic of Ireland. Skin puckering is suggestive of soft tissue interposition and may be an important clinical sign indicating the need for internal fixation.

  11. Anterior glenoid rim fracture: the value of helical CT with threedimensional reconstruction and electronic humeral disarticulation

    Directory of Open Access Journals (Sweden)

    Heverton César de Oliveira

    2003-06-01

    Full Text Available Objectives: To show a new three-dimensional reconstructiontechnique based on helical computed tomography images withelectronic humeral disarticulation in anterior glenoid rim fractures,correlating the anatomic specimen with simulation of an anteriorglenoid rim fracture, as well as evaluating the extension of thefracture, the bone fragment position and distance in relation to theglenoid cavity in six patients. Methods: One scapula and onehumerus with no signs of fracture or congenital malformationswere placed in anatomical position using an adhesive tape aftersimulating an anterior glenoid rim fracture made by an osteotome.Helical CT imaging was acquired and three-dimensionalreconstructions were made based on these images, with andwithout electronic humeral disarticulation. The bone fragment waslocated, measured and its position in relation to the glenoid cavitywas assessed. Six patients with anterior glenoid rim fracture weresubmitted to CT of the shoulder using the same parameters asthose applied to the anatomic specimen. Results: In the anatomicspecimen and in all six patients the bone fragment was clearlydemonstrated; bone fragment measurements in the anatomicspecimen and in three-dimensional reconstructions wereequivalent. The fragment was better demonstrated in the imagestaken with electronic humeral disarticulation, particularly in thefrontal view of the glenoid cavity as observed in all six patients.Conclusion: We concluded that our experiment with the anatomicspecimen and the study of six patients allow us to state that thistechnique is safe and accurate to demonstrate the extension, sizeand location of the bone fragment in anterior glenoid rim fractures,and it provides essential elements for therapeutic planning.

  12. [A new method of osteosynthesis in proximal humeral fractures: a new internal fixation device. Apropos of 17 cases followed over more than 2 years].

    Science.gov (United States)

    Doursounian, L; Grimberg, J; Cazeau, C; Touzard, R C

    1996-01-01

    The authors describe a new internal fixation device, and report on 17 proximal humeral fractures managed with this technique. The fracture patterns, using Neer's classification were: 9 displaced three-part fractures, 4 displaced four-part fractures and 4 interior fracture dislocations (mean age of the patients: 70 years). The device is a two-part titanium device. The humeral component has a long vertical stem cemented in the humeral shaft; and a short proximal portion set at an angle of 135 degrees on the stem, with a neck and a Morse taper cone. The other part is a crown-shaped stapple, whose base is a perforated disk with a central Morse taper socket. The rim of the crown has five prongs which, together with the central socket, are impacted in the cancellous bone of the humeral head. The taper of the humeral component is inserted into the central socket of the stapple to provide fracture fixation. Tuberosities are reattached to the shaft with non absorbable sutures. Mean follow-up was 29 months. The global ratings were as follows: 4 excellent results, 6 good results, 4 fair results, 3 poor results. Mean active forward flexion: 100 degrees, and mean active external rotation 22 degrees. After exclusion of the 4 fracture-dislocations, the global rating became: 4 excellent results, 5 good results, 3 fair results, 1 poor result. Mean active forward flexion: 110 degrees and mean active external rotation: 31.5 degrees. There were no case of avascular necrosis in 13 patients. Complications requiring surgery occurred in one case: an upper protrusion of the stapple which required replacement of the stapple by a prosthetic humeral head. Other complications included: 2 asymptomatic partial protrusions of the stapple, 2 complete and two partial avascular necrosis in fracture-dislocations. Except for the fracture-dislocations our device confers several major benefits. The humeral head is preserved. Typical problems associated with joint replacement (dislocations, loosening

  13. Intramedullary screw fixation with bone autografting to treat proximal fifth metatarsal metaphyseal-diaphyseal fracture in athletes: a case series

    Directory of Open Access Journals (Sweden)

    Tsukada Sachiyuki

    2012-07-01

    Full Text Available Abstract Background Delayed unions or refractures are not rare following surgical treatment for proximal fifth metatarsal metaphyseal-diaphyseal fractures. Intramedullary screw fixation with bone autografting has the potential to resolve the issue. The purpose of this study was to evaluate the result of the procedure. Methods The authors retrospectively reviewed 15 athletes who underwent surgical treatment for proximal fifth metatarsal metaphyseal-diaphyseal fracture. Surgery involved intramedullary cannulated cancellous screw fixation after curettage of the fracture site, followed by bone autografting. Postoperatively, patients remain non weight-bearing in a splint or cast for two weeks and without immobilization for an additional two weeks. Full weight-bearing was allowed six weeks postoperatively. Running was permitted after radiographic bone union, and return-to-play was approved after gradually increasing the intensity. Results All patients returned to their previous level of athletic competition. Mean times to bone union, initiation of running, and return-to-play were 8.4, 8.8, and 12.1 weeks, respectively. Although no delayed unions or refractures was observed, distal diaphyseal stress fractures at the distal tip of the screw occurred in two patients and a thermal necrosis of skin occurred in one patient. Conclusions There were no delayed unions or refractures among patients after carrying out a procedure in which bone grafts were routinely performed, combined with adequate periods of immobilization and non weight-bearing. These findings suggest that this procedure may be useful option for athletes to assuring return to competition level.

  14. Twenty-degree-tilt radiography for evaluation of lateral humeral condylar fracture in children

    International Nuclear Information System (INIS)

    Imada, Hideaki; Tanaka, Ryuji; Itoh, Yohei; Kishi, Kazuhiko

    2010-01-01

    To investigate the efficacy of '20 -tilt anteroposterior (A-P) radiography' in the assessment of lateral condylar fractures of the distal humerus. Eighteen children with lateral humeral condylar fractures were studied. Every child underwent conventional A-P and lateral radiography, and six children underwent multi-detector computed tomography (MDCT). For the investigation of 20 -tilt radiography, ten children with lateral humeral condylar fractures had conventional and 20 -tilt A-P and lateral radiography both preoperatively and postoperatively. Fragment dislocation was measured at the lateral and medial margins of the fracture on both the conventional A-P and 20 -tilt A-P radiographs. The lateral condylar fragment was triangular and was most prominent posteriorly. The fracture line was typically tilted approximately 20 to a reference line perpendicular to the long axis of the humerus in the lateral view. The extent of dislocation at the lateral and medial margins of the fracture site by 20 -tilt A-P radiography (9.3 ± 3.6 mm and 5.6 ± 2.5 mm) was significantly wider than that measured by the conventional method (6.8 ± 4.1 mm and 2.0 ± 1.5 mm), which may influence treatment. Twenty-degree-tilt A-P radiography may more precisely demonstrate fragment dislocation than standard radiographs and may influence patient treatment. (orig.)

  15. The reliability and reproducibility of the Hertel classification for comminuted proximal humeral fractures compared with the Neer classification

    NARCIS (Netherlands)

    Iordens, Gijs I. T.; Mahabier, Kiran C.; Buisman, Florian E.; Schep, Niels W. L.; Muradin, Galied S. R.; Beenen, Ludo F. M.; Patka, Peter; van Lieshout, Esther M. M.; den Hartog, Dennis

    2016-01-01

    The Neer classification is the most commonly used fracture classification system for proximal humeral fractures. Inter- and intra-observer agreement is limited, especially for comminuted fractures. A possibly more straightforward and reliable classification system is the Hertel classification. The

  16. Real frequency of ordinary and atypical sub-trochanteric and diaphyseal fractures in France based on X-rays and medical file analysis.

    Science.gov (United States)

    Beaudouin-Bazire, Constance; Dalmas, Noémie; Bourgeois, Julie; Babinet, Antoine; Anract, Philippe; Chantelot, Christophe; Farizon, Frédéric; Chopin, Florence; Briot, Karine; Roux, Christian; Cortet, Bernard; Thomas, Thierry

    2013-03-01

    Atypical sub-trochanteric and femoral shaft fractures have been reported in patients treated with bisphosphonates. Their incidence has been determined from registered data analysis using international codes. Therefore, the aim of our study was to estimate the real frequency of typical and atypical sub-trochanteric or diaphyseal fractures, based on radiological and clinical data compared to registered data. In the registers of three large French University Hospitals, patients identified with International Classification of Diseases, 10th Revision diagnosis codes for sub-trochanteric or diaphyseal fracture were selected. Frequencies of ordinary and atypical fractures were calculated after both registered data, radiological and clinical files analysis. Among the 4592 patients hospitalized for a femoral fracture over 5 years, 574 were identified to have had a sub-trochanteric or femoral shaft fracture. 47.7% of the sub-trochanteric and femoral shaft fractures were misclassified, predominantly in the sub-trochanteric fractures subset. 12 patients had an atypical fracture (4% of the sub-trochanteric and femoral shaft fractures) and 11 fractures presented radiological features of atypical fractures, whereas clinical files analysis revealed they were pathological or traumatic fractures. Atypical fractures frequency is very low. Because of their low frequency and the unreliability of registered databases, the risk of atypical fractures is very difficult to estimate retrospectively. A prospective study is needed to clarify the risk factors associated with these fractures. Copyright © 2012 Société française de rhumatologie. Published by Elsevier SAS. All rights reserved.

  17. Proximal humeral fractures: the role of calcium sulphate augmentation and extended deltoid splitting approach in internal fixation using locking plates.

    Science.gov (United States)

    Somasundaram, K; Huber, C P; Babu, V; Zadeh, H

    2013-04-01

    The aim of our study is to analyse the results of our surgical technique for the treatment of proximal humeral fractures and fracture dislocations using locking plates in conjunction with calcium sulphate bone-substitute augmentation and tuberosity repair using high-strength sutures. We used the extended deltoid-splitting approach for fracture patterns involving displacement of both lesser and greater tuberosities and for fracture-dislocations. Optimal surgical management of proximal humeral fractures remains controversial. Locking plates have become a popular method of fixation. However, failure of fixation may occur if they are used as the sole method of fixation in comminuted fractures, especially in osteopenic bone. We retrospectively analysed 22 proximal humeral fractures in 21 patients; 10 were male and 11 female with an average age of 64.6 years (range 37-77). Average follow-up was 24 months. Eleven of these fractures were exposed by the extended deltoid-splitting approach. Fractures were classified according to Neer and Hertel systems. Preoperative radiographs and computed tomography (CT) scans in three- and four-part fractures were done to assess the displacement and medial calcar length for predicting the humeral head vascularity. According to the Neer classification, there were five two-part, six three-part, five four-part fractures and six fracture-dislocations (two anterior and four posterior). Results were assessed clinically with disabilities of the arm, shoulder and hand (DASH) scores, modified Constant and Murley scores and serial postoperative radiographs. The mean DASH score was 16.18 and the modified Constant and Murley score was 64.04 at the last follow-up. Eighteen out of twenty-two cases achieved good clinical outcome. All the fractures united with no evidence of infection, failure of fixation, malunion, tuberosity failure, avascular necrosis or adverse reaction to calcium sulphate bone substitute. There was no evidence of axillary nerve

  18. Correlation between classification and secondary screw penetration in proximal humeral fractures.

    Directory of Open Access Journals (Sweden)

    Qiuke Wang

    Full Text Available In this study, we investigated the correlation between fracture classification and secondary screw penetration.We retrospectively identified 189 patients with displaced proximal humeral fractures treated by ORIF at our hospital between June 2006 and June 2013. All fractures were classified radiographically before surgery and follow-up for least 2 years after surgery was recommended. At each follow-up, radiographs were taken in three orthogonal views to evaluate secondary screw penetration.The study population consisted of 189 patients. Of these, 70 were male and 119 female, with a mean age of 59.1 years; the mean follow-up time was 28.5 months. Secondary screw penetration occurred in 26 patients. The risk of developing secondary screw penetration was 11.3-fold higher in four-part fractures than two-part fractures (P 0.05.Patients with four-part fractures, type C fractures and medial hinges disruption are vulnerable to secondary screw penetration. This allows additional precautions to be instituted and measures to be taken as needed.

  19. A new internal fixation technique for fractures of the proximal humerus--the Bilboquet device: a report on 26 cases.

    Science.gov (United States)

    Doursounian, L; Grimberg, J; Cazeau, C; Jos, E; Touzard, R C

    2000-01-01

    We describe a novel internal fixation device and report on 26 patients (mean age, 70 years) whose proximal humeral fractures were managed with this technique. The 2-part titanium implant consists of a circular staple impacted into the humeral head cancellous bone and a spigoted diaphyseal stem that inserts into the staple "cup." Of the 26 cases reviewed, 16 had 3-part fractures and 10 had 4-part fractures. Mean follow-up was 25.9 months. In the 16 3-part fractures, the mean active forward elevation was 114 degrees and the results were as follows: excellent, 7; good, 5; fair, 3; poor, 1. In the 10 4-part fracture patients, the mean active forward elevation was 101 degrees and the results were as follows: excellent, 2; good, 4; fair, 3; poor, 1. There were 5 cases of avascular necrosis and 1 case of tuberosity nonunion. Only 2 cases needed conversion to hemiarthroplasty. The new technique should simplify the surgery of these fractures and reduce the need for arthroplasty.

  20. "Push-past" reaming as a reduction aid with intramedullary nailing of metadiaphyseal and diaphyseal femoral shaft fractures.

    Science.gov (United States)

    Gary, Joshua L; Munz, John W; Burgess, Andrew R

    2014-06-01

    Eccentric reaming of cortical bone near a fracture site can introduce malalignment when an intramedullary nail is placed. The authors describe a technique of reaming metadiaphyseal and diaphyseal femur fractures in which maintaining reduction at the fracture site is not necessary to obtain an excellent alignment of long bone fractures after intramedullary nailing. They have found that central reaming proximal and distal to, but not at, the fracture site allows for excellent reduction of long bone fractures when the intramedullary nail is passed. The reamer is stopped just before the fracture site and then "pushed" across the fracture prior to resumption of reaming. The authors present "push-past" reaming as a technical trick to facilitate reduction of femoral fractures treated with intramedullary nails and a consecutive series of 18 cases in which excellent postoperative alignment was achieved. Copyright 2014, SLACK Incorporated.

  1. Features of Three- and Four-Part Proximal Humeral Fractures and Outcome of Internal Fixation Using the Philos® Locking Plate

    Directory of Open Access Journals (Sweden)

    Ali Sadighi

    2017-03-01

    Full Text Available Background: Proximal humeral fractures are among common types of fractures and remain a challenging issue for surgical management. This study aimed to assess the clinical outcomes and complication rates of three- vs. four-part proximal humeral fractures, treated with internal fixation using the Philos® plate. Material and Methods: In this cohort study, a total of 30 consecutive patients with three-part or four-part proximal humeral fractures based on the Neer classification were included. Surgical treatment was performed with open reduction and internal fixation using the Philos® plate. The constant score was evaluated 6 months later in follow-up. The P<0.05 was considered significant. Results: Four-part fractures were mainly caused by trauma from above, while insults of opposite direction were responsible for more than half of 3 part fractures (P=0.01. Open fractures were only observed in patients with a four-part fracture (P=0.018. No significant differences were noticed regarding gender, cause, and side of the fracture. The presence of other fractures, fracture of the implant, reduction loss, avascular necrosis (AVN of humerus head, rotator cuff injury, and revision surgery were significantly higher in patients with four-part fractures. The mean constant score was 81.40±11.61 and 65.09±16.09 for three-part and four-part fractures, respectively (P=0.006. Conclusion: Open reduction and internal fixation with Philos® plate yield acceptable results in both types of fractures, however, the prognosis of this intervention is poorer four-part fractures.

  2. A prospective randomized study of operative treatment for noncomminuted humeral shaft fractures: conventional open plating versus minimal invasive plate osteosynthesis.

    Science.gov (United States)

    Kim, Ji Wan; Oh, Chang-Wug; Byun, Young-Soo; Kim, Jung Jae; Park, Ki Chul

    2015-04-01

    To compare the clinical and radiologic results of conventional open plating (COP) and minimally invasive plate osteosynthesis (MIPO) in the treatment of noncomminuted humeral shaft fractures. Randomized prospective study. Five level 1 trauma centers. Sixty-eight consecutive patients were randomized into 2 study groups: those treated by COP (COP group; n = 32) and those treated by MIPO (MIPO group; n = 36). Simple humeral shaft fractures (AO/OTA classification types A and B) were reduced by open reduction or closed reduction and fixed with a narrow 4.5/5.0 locking compression plate, metaphyseal locking compression plate, or proximal humeral internal locking system plate to the anterior lateral aspect of the humerus. Fracture healing time, operative time, radiation exposure time, and intraoperative nerve injury. To assess shoulder and elbow function, we used the University of California, Los Angeles (UCLA) scoring system and the Mayo elbow performance index, including the range of motion and pain. Radiographic measurements included fracture alignment, delayed union, and nonunion. Thirty-one fractures (97%) healed in the COP group within 16 weeks, whereas 36 fractures (100%) were healed in the MIPO group by 15 weeks. No significant difference was observed in the operative time or complication rates. In both groups, all fractures achieved union without malunion and with excellent functional outcomes by definition of the Mayo elbow performance index and UCLA scoring system. This study confirmed a high overall rate of union and excellent functional outcomes in both MIPO and COP groups. MIPO is equivalent to COP as a safe and effective method for simple types of humeral shaft fractures when surgery is indicated, and the surgeon is experienced in the technique. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

  3. Biomechanical evaluation of straight antegrade nailing in proximal humeral fractures: the rationale of the "proximal anchoring point".

    Science.gov (United States)

    Euler, Simon A; Petri, Maximilian; Venderley, Melanie B; Dornan, Grant J; Schmoelz, Werner; Turnbull, Travis Lee; Plecko, Michael; Kralinger, Franz S; Millett, Peter J

    2017-09-01

    Varus failure is one of the most common failure modes following surgical treatment of proximal humeral fractures. Straight antegrade nails (SAN) theoretically provide increased stability by anchoring to the densest zone of the proximal humerus (subchondral zone) with the end of the nail. The aim of this study was to biomechanically investigate the characteristics of this "proximal anchoring point" (PAP). We hypothesized that the PAP would improve stability compared to the same construct without the PAP. Straight antegrade humeral nailing was performed in 20 matched pairs of human cadaveric humeri for a simulated unstable two-part fracture. Biomechanical testing, with stepwise increasing cyclic axial loading (50-N increments each 100 cycles) at an angle of 20° abduction revealed significantly higher median loads to failure for SAN constructs with the PAP (median, 450 N; range, 200-1.000 N) compared to those without the PAP (median, 325 N; range, 100-500 N; p = 0.009). SAN constructs with press-fit proximal extensions (endcaps) showed similar median loads to failure (median, 400 N; range, 200-650 N), when compared to the undersized, commercially available SAN endcaps (median, 450 N; range, 200-600 N; p = 0.240). The PAP provided significantly increased stability in SAN constructs compared to the same setup without this additional proximal anchoring point. Varus-displacing forces to the humeral head were superiorly reduced in this setting. This study provides biomechanical evidence for the "proximal anchoring point's" rationale. Straight antegrade humeral nailing may be beneficial for patients undergoing surgical treatment for unstable proximal humeral fractures to decrease secondary varus displacement and thus potentially reduce revision rates.

  4. Complications during removal of stainless steel versus titanium nails used for intramedullary nailing of diaphyseal fractures of the tibia

    OpenAIRE

    Mustafa Seyhan; Olcay Guler; Mahir Mahirogullari; Ferdi Donmez; Arel Gereli; Serhat Mutlu

    2018-01-01

    Objectives: Intramedullary nailing is the treatment of choice for fractures of the tibial shaft, which might necessitate the nail removal due to complications in the long-term. Although considered as a low-risk procedure, intramedullary nail removal is also associated with certain complications. Here, we compared the most commonly used stainless steel and titanium nails with respect to the complications during removal and clinical outcome for intramedullary nailing of diaphyseal fractures of ...

  5. Complications during removal of stainless steel versus titanium nails used for intramedullary nailing of diaphyseal fractures of the tibia

    OpenAIRE

    Seyhan, Mustafa; Guler, Olcay; Mahirogullari, Mahir; Donmez, Ferdi; Gereli, Arel; Mutlu, Serhat

    2018-01-01

    Objectives Intramedullary nailing is the treatment of choice for fractures of the tibial shaft, which might necessitate the nail removal due to complications in the long-term. Although considered as a low-risk procedure, intramedullary nail removal is also associated with certain complications. Here, we compared the most commonly used stainless steel and titanium nails with respect to the complications during removal and clinical outcome for intramedullary nailing of diaphyseal fractures of t...

  6. A STUDY ON PROXIMAL HUMERAL FRACTURES STABILISED WITH PHILOS PLATE

    Directory of Open Access Journals (Sweden)

    Praveen Sivakumar K

    2017-02-01

    Full Text Available BACKGROUND Techniques for treating complex proximal humeral fractures vary and include fixations using tension bands, percutaneous pins, bone suture, T-plates, intramedullary nails, double tubular plates, hemiarthroplasty, plant tan humerus fixator plates, Polaris nails and blade plates. Complications of these techniques include cutout or back out of the screws and plates, avascular necrosis, nonunion, malunion, nail migration, rotator cuff impairment and impingement syndromes. Insufficient anchorage from conventional implants may lead to early loosening and failure, especially in osteoporotic bones. In general, nonoperative treatment of displaced three and four-part fractures of the proximal humerus leads to poor outcome due to intraarticular nature of injury and inherent instability of the fragments. Comminuted fractures of the proximal humerus are at risk of fixation failure, screw loosening and fracture displacement. Open reduction and internal fixation with conventional plate and screws has been associated with unacceptably high incidence of screw pull out. PHILOS (the proximal humeral internal locking system plate is an internal fixation system that enables angled stabilisation with multiple interlocking screws for fractures of the proximal humerus. MATERIALS AND METHODS 30 patients with proximal humerus fractures who were admitted in the Department of Orthopaedics, Government General Hospital, Kakinada, during the period November 2014 - November 2016 were taken up for study according to inclusion criteria. All patients were treated with PHILOS plate. These proximal humerus fractures were classified according to Neer’s classification. Patients were followed up at 6 weeks, 12 weeks and 6 months’ interval. Functional outcomes for pain, range of motion and muscle power and function were assessed using the Constant-Murley scoring system. Collected data analysed with independent t-test and ANNOVA test. RESULTS The outcome of the study was 1

  7. [Epidemiology, treatment and results of proximal humeral fractures: experience of a district hospital in a sports- and tourism area].

    Science.gov (United States)

    Sonderegger, J; Simmen, H-P

    2003-02-01

    The epidemiology, therapy and results of proximal humeral fractures in a touristic area were investigated and our concept for treatment presented. Between 1.1.1999 and 30.04.2000 adult patients with proximal humeral fractures were included, the fractures classified (Codman/Neer and AO) and results determined after an average of 9 months. 62 adults were treated. 59 (95 %) had an accident during leisure time, mainly skiing accidents (52 %). 7 patients (11 %) had an associated luxation of the shoulder. 51 (82 %) were treated conservatively, 11 (18 %) operatively with a T-plate. The conservatively treated had to wear a Gilchrist-cast for an average of 29 (operatively 13) days, started passive movement after 20 (operatively 9) days, and active movement after 44 (operatively 45) days. The 32 employed (52 %) were not able to work for 46 days on average. Overall, 52 patients (84 %) were totally or mostly satisfied with the result. 5 among the 13 patients (38.5 %) with 3- or 4-part-fractures, and 4 among the 11 operated patients (36.4 %) were not satisfied with the result. Proximal humeral fractures are common skiing injuries, they need a long and intensive treatment and are economically expensive. The Codman/Neer and AO-classifications are equal. The results for simple, mainly conservatively treated fractures (Codman/Neer 1, 2A, 2-part) are good. Complex, mainly operatively treated fractures (Codman/Neer 3- and 4-part) have a much poorer prognosis. Diagnostically the computed tomography with 3-D-reconstruction is recommended for a better representation of the fracture and a safer choice of the therapeutical strategy.

  8. Minimally invasive plate osteosynthesis for humeral shaft fracture: a reproducible technique with the assistance of an external fixator.

    Science.gov (United States)

    Lee, Hyun-Joo; Oh, Chang-Wug; Oh, Jong-Keon; Apivatthakakul, Theerachai; Kim, Joon-Woo; Yoon, Jong-Pil; Lee, Dong-Joo; Jung, Jae-Wook

    2013-05-01

    Minimally invasive plate osteosynthesis (MIPO) has become a popular option for treatment of humeral shaft fractures. However, indirect reduction might risk unpromising results, with mal-alignment/mal-union or nonunion. The purpose of this study was to describe a reproducible MIPO technique that used an external fixator during the procedure as a tool for reduction and maintenance, and to assess the outcomes in patients with humeral shaft fracture. Of 31 consecutive cases of humeral shaft fracture in 30 patients, 29 were included in this study. There were seven simple (type A) and 22 comminuted (type B or C) fractures. After the insertion of one Schanz pin on each proximal and distal humerus, a provisional reduction was achieved by connecting the pins with a monolateral external fixator. The MIPO procedure was then performed over the anterior aspect of the humerus. To evaluate the efficacy of the provisional reduction by external fixator, coronal and sagittal alignments were assessed. We also assessed bony and functional results, including complications, from this technique. There was no case of mal-union >10°, and mean angulation was 1.3° (range 0°-9°) in the coronal plane and 1.2° (range 0°-8°) in the sagittal plane. Twenty-eight of 29 fractures were united, including three delayed unions, with a mean union time of 19.1 weeks (range 12.3-38.4 weeks) and a mean follow-up of 20.8 months (range 13.5-31.0 months). There was one hypertrophic nonunion that healed after fixing with two additional screws. Except one patient with associated injury in the elbow, all patients recovered to pre-injury joint motion. There were two cases of postoperative radial nerve palsy that both recovered completely. We attributed them to manipulation, and not to the Schanz pins or plate fixation. Surgical treatment of humeral shaft fractures with external fixator-assisted reduction and MIPO resulted in excellent reductions and high union rates.

  9. Surgical management for displaced pediatric proximal humeral fractures: a cost analysis

    OpenAIRE

    Shore, Benjamin J.; Hedequist, Daniel J.; Miller, Patricia E.; Waters, Peter M.; Bae, Donald S.

    2015-01-01

    Purpose The purpose of this investigation was to determine which of the following methods of fixation, percutaneous pinning (PP) or intramedullary nailing (IMN), was more cost-effective in the treatment of displaced pediatric proximal humeral fractures (PPHF). Methods: A retrospective cohort of surgically treated PPHF over a 12-year period at a single institution was performed. A decision analysis model was constructed to compare three surgical strategies: IMN versus percutaneous pinning leav...

  10. [Comparison of clinical effect on locking plate for proximal humeral fracture with or without application of inferomedial screws].

    Science.gov (United States)

    Guo, Xiu-wu; Fan, Jian; Yuan, Feng

    2016-06-01

    To compare clinical outcomes of locking plate for proximal humeral fracture whether application of inferomedial screws. From January 2012 to July 2013, 46 patients with proximal humeral fracture underwent locking plates were retrospectively analyzed. There were 25 males and 21 females aged from 29 to 80 years old with an average of 55.1 years old. Among them, 25 patients were treated with inferomedial screws (support group), including 13 males and 12 females aged from 38 to 80 years old with an average of (55.8 ± 11.8) years old; 8 cases were part two fracture,10 cases were part three fracture and 7 cases were part four fracture according to Neer classification. Twenty-one patients were treated without inferomedial screws (non-support group), including 12 males and 9 females aged from 29 to 79 years old with an average of (54.2 ± 14.8)years old; 6 cases were part two fracture, 9 cases were part three fracture and 6 cases were part four fracture according to Neer classification. Operative time, fracture healing time and complications were observed and compared, Neer scoring of shoulder joint were used to evaluate clinical effect. All patients were followed up from 12 to 41 months with an average of 15.6 months. Operative time and fracture healing time in support group was (1.6 ± 0.4) h and (3.0 ± 0.6) months, and (1.5 ± 0.4) h and (3.1 ± 0.6) months in non-support group, while there was no statistical difference in operative time and fracture healing time between two groups. There was significant differences in Neer score between support group (89.7± 4.9) and non-support group (83.1 ± 7.1). No complication occurred in support group,while 4 cases occurred complications in non-support group. Locking plate with inferomedial screws for proximal humeral fracture has advantages of stable fixation, less complications, quick recovery of function and satisfied clinical effect.

  11. Brachial Plexus Injury in a 6-Year-Old Boy with 100% Displaced Proximal Humeral Metaphyseal Fracture: A Case Presentation.

    Science.gov (United States)

    Jovanovich, Elizabeth Nora; Howard, James F

    2017-12-01

    Posttraumatic brachial plexopathies can occur following displaced proximal humeral fractures, causing profound functional deficits. Described here is an unusual case of a displaced proximal humeral metaphyseal fracture in a young child. The patient underwent closed reduction and serial casting, but hand weakness and forearm sensory loss persisted. Needle electromyography localized the injury to the mid/proximal arm near the fracture site, resulting in damage to the posterior and medial cords of the brachial plexus with profound involvement of the radial, ulnar, and median nerves and sparing of the axillary nerve. After months of occupational therapy, hand strength improved, with a nearly full return of function. V. Copyright © 2017 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  12. COMPARATIVE STUDY BETWEEN TITANIUM ELASTIC NAILING (TENS AND DYNAMIC COMPRESSION PLATING (DCP IN THE TREATMENT OF FEMORAL DIAPHYSEAL FRACTURES IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Ramasubba Reddy

    2015-08-01

    Full Text Available BACKGROUND : Orthopaedic surgeons have long maintained that all children who have sustained a diaphyseal fracture of femur recover with c onservative treatment, given the excellent remodeling ability of immature bone in children. Angulations, shortenings and malrotations are not always corrected by conservative treatment. Of many surgical options, titanium elastic nailing has been the newer implant which is being used regularly. Although good results have been reported with elastic intramedullary nails, plate fixation continues to be a viable alternative in surgical treatment of femoral shaft fractures. However there are not many studies comp aring the efficiency of titanium elastic nailing and plating for femoral diaphyseal fractures in pediatric age group. AIM : The present study aims to compare the surgical management of diaphyseal fractures of femur in children with Dynamic Compression Plati ng versus Titanium Elastic Nailing. DESIGN : This is a prospective study . MATERIALS AND METHODS : This prospective study was conducted in a tertiary hospital. Patients who presented to the out - patient department and casualty of the hospital with femoral diap hyseal fractures during April 2012 to June 2014 were considered for the study. Subjects fulfilling the predetermined inclusion and exclusion criteria were included in the study. STATISTICAL METHODS : Fisher Exact test, Chi - Square Test, Student t test (Two t ailed, independent . RESULTS : Patients in the age group of 6 - 14 years were considered for the study, Patients were divided into two groups and treated with DCP/TENS. The duration of surgery, hospital stay, and, amount of blood loss was minimal in TENS grou p. Callus was seen early in TENS group. Radiological union was early in TENS group by 2 - 3 weeks. Outcome was better in patients treated with TENS (Excellent - 70%; Satisfactory – 30%; Poor - 0% in comparison to DCP (Excellent - 70%; Satisfactory - 25%; Poor - 5%. CO NCLUSION : TENS

  13. Hertel 7 fracture of the humeral head. Can two different fixation systems (Diphos/PHP) lead to different outcomes? A retrospective study.

    Science.gov (United States)

    Gumina, S; Baudi, P; Candela, V; Campochiaro, G

    2016-10-01

    To compare clinical outcomes and complication rates in the medium-to-long-term follow-up of Hertel 7 humeral head fractures treated with two different locking plates. A total of 52 patients with type 7 humeral head fracture (in accordance with Hertel classification) were enrolled retrospectively: 24 patients [4 male, 20 female; mean age (standard deviation [SD]): 68.9 (5.8) years] were treated with Diphos H plate (Group A) and 28 patients [6 male, 22 female; mean age (SD): 61.0 (7.5) years] with Proximal Humeral Plate (PHP; Group B). The mean follow-up periods were 25.6 and 18.9 months, respectively. Functional outcomes were assessed using the Constant score and Disabilities of the Arm, Shoulder and Hand (DASH) score; X-ray evaluation was also performed and complications were recorded. The mean Constant score in the Diphos and PHP groups at follow-up were 75.6 (SD 13.4) and 78.9 (SD 12.8), respectively (p>0.05). The DASH score was similar in both groups (Diphos: 18.6, range 0-51.5; PHP: 16.8, range 0-47.8) (p>0.05). In our series, 9.6% of patients had complications; these included a case of aseptic non-union and a case of avascular necrosis of the humeral head in each group, and a secondary screw perforation in a patient treated with Diphos. In patients with Hertel 7 proximal humeral fractures, Diphos and PHP lead to similar satisfactory functional outcomes and are associated with low complication rates; this confirms that both are useful implants for the treatment of this pattern of fracture. Copyright © 2016. Published by Elsevier Ltd.

  14. Difference between radiological and functional outcome with deltoid-splitting approach versus deltopectoral approach for the management of proximal humeral fractures with philos plate

    Directory of Open Access Journals (Sweden)

    Shah Waliullah

    2013-01-01

    Full Text Available Background: Proximal humeral fractures are one of the common fractures of upper extremity. Good results by various studies have been reported for proximal humeral locking plate (PHILOS fixation in proximal humeral fractures. We want to evaluate whether it is only the implant which has given good results or different surgical approach utilized for fixation of plate also affects result. Materials and Methods: A total of 57 patients with proximal humeral fractures were divided in two groups, in Group A, patient′s classical deltopectoral approach utilized, while in Group B deltoid-splitting approach was used. All patients were managed by PHILOS plate fixation. Cases were followed up clinically as well as radiologically at 4-6 weeks after operation and thereafter at 10-12 weeks and then at 6 monthly for long-term complications. Functional outcomes of patient were accessed in terms Constant Scoring System, while radiological evaluation was done by taking x-rays to access quality of reduction and union of fracture. Results: All patients were followed for a minimum of 18 months. In Group B, reduction of tuberosities was better in 3 part and 4 part fractures. Mean Constant score in Group A at the end of 3 months was 56, while in Group B it was 62 and statistically significant (P = 0.02. At the end of 18 months, mean Constant score in Group A was 79, while in Group B it was 81 and statistically insignificant (P = 0.72. One patient in Group B showed axillary nerve paresis in postoperative period and recovered at the end of 3 months. Conclusion: We recommend that deltoid-splitting approach can be used in 3 part and 4 part complex proximal humeral fractures and in posterior fracture dislocation shoulder, which are difficult to approach with deltopectoral approach; however, care should be taken while inserting calcar screw in PHILOS plate fixation to avoid iatrogenic axillary nerve injury.

  15. Diaphyseal Fractures of the Forearm in Adults, Plating Or Intramedullary Nailing Is a Better Option for the Treatment?

    Directory of Open Access Journals (Sweden)

    Tabet A. Al-Sadek

    2016-11-01

    Full Text Available BACKGROUND: Fractures of the radius and ulna occupy a large field of the modern traumatology. Therefore, these fractures are a major subject in modern orthopaedics and traumatology. The study of the mechanisms of the trauma, and the pathophysiological changes that occur are of great importance for the development of ever more efficient and varied ways of the treatment and prophylactics of this type of fracture. AIM: The aim of this paper was to study the pattern of the diaphyseal fractures of the forearm in adults, to decide the modalities of surgical management, to observe the period of fracture healing clinically and radiologically, as well to study the rehabilitation of the patients. MATERIAL AND METHODS: The present study included 45 cases of diaphyseal fractures of both bones forearm in adults presenting to the orthopaedic outpatient department. For all the patients a detailed history was taken. A thorough clinical examination was carried out, required X-rays were taken, and initial treatment was given and admitted as in all patients. After careful pre-operative planning and evaluation for anaesthetic fitness, patients were operated for the fractures of both bone forearms. Twenty-three cases with 46 fractures were treated by open reduction and rigid fixation with DCP & Semi-tubular plates and 22 cases with 44 fractures were treated by closed reduction and fixation with “Talwarkar” intramedullary square nails. RESULTS: United results were found in 100% of plating group vs. 86% in the nailing group. Delayed and non-union results were found in 9% of the nailing group only. Average time to union in weeks was 9.4 weeks in the plating group vs. 10.2 weeks in the nailing group. CONCLUSION: Open reduction and internal fixation with compression plates with strict adherence to surgical technique is the gold standard method of treatment in both bones forearm fractures with excellent results than closed reduction, internal fixation with

  16. Use of Titanium Elastic Nails in the Adult Diaphyseal Humerus Fractures

    Directory of Open Access Journals (Sweden)

    Upadhyay AS

    2017-07-01

    Full Text Available INTRODUCTION: Humerus shaft fractures in adults can be managed conservatively with functional braces or operatively with plate osteosynthesis or with intramedullary nailing. Conventionally humerus intramedullary nailing is done either using humerus interlocking nails or Enders nails. In this study we analyse the outcome of humerus shaft fractures (upper and middle third managed with closed ante- grade intramedullary titanium elastic nailing in terms of union rates, union time, functional results and complications. MATERIALS AND METHODS: A retrospective analysis of 25 patients treated with ante-grade intramedullary titanium elastic nailing was done during the period of August 2014 to June 2016 at our tertiary care centre. Skeletally mature patients with closed and acute fractures of the upper and middle shaft humerus of both sexes were included in the study. RESULTS: Twenty-five (100% fractures united with an average consolidation time of 14.98 weeks (10-32 weeks, and no fractures ended in non-union. Nail impingement was seen in two (8%, shoulder stiffness in one (4%. Functional results were excellent in 22 (88%, moderate in two (8% and poor in one (4%. There were 17 males and eight females with an average age of 39.08 years (range: 18-65 years. The average duration of hospital stay was 3.84±2.30 days. CONCLUSION: Closed ante-grade intramedullary titanium elastic nailing offers a safe and reliable method of fixing fractures of upper humeral shaft in adults. This method provides early fracture union, high union rates and less complications, in addition to early rehabilitation and reduces the hospital stay.

  17. Evaluation of shoulder and elbow functions after treatment of humeral shaft fractures: a 20-132-month follow-up study.

    Science.gov (United States)

    Fırat, Ahmet; Deveci, Alper; Güler, Ferhat; Oçgüder, Ali; Oğuz, Temel; Bozkurt, Murat

    2012-01-01

    The aim of this study was to evaluate the long-term results of shoulder and elbow functions in humeral shaft fractures treated with functional brace, plate and screw osteosynthesis or intramedullary nailing. The study included 128 patients treated for humeral shaft fracture. The patients were divided into three groups according to treatment method: Group 1 (n=62) received functional brace, Group 2 (n=36) plate and screw osteosynthesis and Group 3 (n=30) intramedullary nailing. Coronal and sagittal humeral angulations were measured radiologically during the final follow-up. Shoulder and elbow functions were evaluated using the Constant shoulder score, the Mayo Elbow Performance Scoring and range of movement measurements. The mean follow-up time was 74 (range: 20 to 132) months. Mean Constant shoulder scores were 92.4 in Group 1, 85.6 in Group 2 and 74 in Group 3. A statistically significant difference was detected between the Constant shoulder scores of Groups 2 and 3 (p0.05). In the statistical evaluation of the Constant shoulder scores, a statistically significant difference was detected between the Constant scores of patients with a varus angulation greater than 20° and those with neutral alignment. Functional results of humeral shaft fractures treated with functional brace appear to be satisfactory. Varus and antecurvatum may affect shoulder and elbow function. In the presence of surgical indications, plate and screw fixation technique is the most effective method in terms of shoulder and elbow functions.

  18. Exchange nailing for nonunion of diaphyseal fractures of the tibia: our results and an analysis of the risk factors for failure.

    Science.gov (United States)

    Tsang, S T J; Mills, L A; Frantzias, J; Baren, J P; Keating, J F; Simpson, A H R W

    2016-04-01

    The aim of this study was to identify risk factors for the failure of exchange nailing in nonunion of tibial diaphyseal fractures. A cohort of 102 tibial diaphyseal nonunions in 101 patients with a mean age of 36.9 years (15 to 74) were treated between January 1992 and December 2012 by exchange nailing. Of which 33 (32%) were initially open injuries. The median time from primary fixation to exchange nailing was 6.5 months (interquartile range (IQR) 4.3 to 9.8 months). The main outcome measures were union, number of secondary fixation procedures required to achieve union and time to union. Univariate analysis and multiple regression were used to identify risk factors for failure to achieve union. Multiple causes for the primary nonunion were found for 28 (27%) tibiae, with infection present in 32 (31%). Six patients were lost to follow-up. Further surgical procedures were required in 35 (36%) nonunions. Other fixation modalities were required in five fractures. A single nail exchange procedure achieved union in 60/96 (63%) of all nonunions. Only 11 out of 31 infected nonunions (35.4%) healed after one exchange nail procedure. Up to five repeated exchange nailings, with or without bone grafting, ultimately achieved union in 89 (93%) fractures. The median time to union after exchange nailing was 8.7 months (IQR 5.7 to 14.0 months). Univariate analysis confirmed that an oligotrophic/atrophic pattern of nonunion (p = 0.002), a bone gap of 5 mm or more (p = 0.04) and infection (p exchange nailing Multiple regression analysis found that infection was the strongest predictor of failure (p Exchange nailing is an effective treatment for aseptic tibial diaphyseal nonunion. However, in the presence of severe infection with a highly resistant organism, or extensive sclerosis of the bone, other fixation modalities, such as Ilizarov treatment, should be considered. Exchange nailing is an effective treatment for aseptic tibial diaphyseal nonunion. ©2016 The British Editorial

  19. [Treatment of proximal humeral fractures by reverse shoulder arthroplasty: mid-term evaluation of functional results and Notching].

    Science.gov (United States)

    Hernández-Elena, J; de la Red-Gallego, M Á; Garcés-Zarzalejo, C; Pascual-Carra, M A; Pérez-Aguilar, M D; Rodríguez-López, T; Alfonso-Fernández, A; Pérez-Núñez, M I

    2015-01-01

    An analysis was made on relationship between Notching and functional and radiographic parameters after treatment of acute proximal humeral fractures with reverse total shoulder arthroplasty. A retrospective evaluation was performed on 37 patients with acute proximal humeral fracture treated by reversed shoulder arthroplasty. The mean follow-up was 24 months. Range of motion, intraoperative and postoperative complications were recorded. Nerot's classification was used to evaluate Notching. Patient satisfaction was evaluated with the Constant Score (CS). Statistical analysis was performed to evaluate the relationship between Notching and glenosphere position, or functional outcomes. Mean range of elevation, abduction, external and internal rotation were 106.22°, 104.46°, 46.08° and 40.27°, respectively. Mean CS was 63. Notching was present at 12 months in 29% of patients. Statistical analysis showed significance differences between age and CS, age and notching development, and tilt with notching. No statistical significance differences were found between elevation, abduction, internal and external rotation and CS either with scapular or glenosphere-neck angle. Reverse shoulder arthroplasty is a valuable option for acute humeral fractures in patients with osteoporosis and cuff-tear arthropathy. It leads to early pain relief and shoulder motion. Nevertheless, it is not exempt from complications, and long-term studies are needed to determine the importance of notching. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.

  20. Minimally invasive plate osteosynthesis for humeral shaft fractures: are results reproducible?

    Science.gov (United States)

    Concha, Juan M; Sandoval, Alejandro; Streubel, Philipp N

    2010-12-01

    Minimally invasive plate osteosynthesis (MIPO) has been advocated as a safe approach to humeral shaft fracture management. We evaluated the reproducibility of this technique in a regional hospital. Thirty-five patients underwent MIPO of humerus shaft fractures. Fifteen patients had an open fracture, six a preoperative radial nerve palsy, and nine a concomitant thoracic, musculoskeletal or vascular injury. At an average 12-month follow-up, 91% of fractures healed after a mean of 12 weeks (range, 8-16). Two infections occurred. Final alignment averaged 4° of varus (range, 5° of valgus to 20° of varus). Active elbow ROM averaged 114° (range, 60-135°) and was less than 100° in nine elbows. Five of six preoperative radial nerve injuries recovered spontaneously. Healing and infection rates in this study are consistent with those reported in the literature. Lower elbow ROM and higher fracture angulation at healing were nevertheless found. MIPO is technically demanding and requires adequate intraoperative imaging and surgical experience in order to obtain adequate fracture alignment. Brachialis muscle scarring and inadequate postoperative rehabilitation may be involved in limited elbow range of motion.

  1. Indications for computed tomography (CT- diagnostics in proximal humeral fractures: a comparative study of plain radiography and computed tomography

    Directory of Open Access Journals (Sweden)

    Weise Kuno

    2009-04-01

    Full Text Available Abstract Background Precise indications for computed tomography (CT in proximal humeral fractures are not established. The purpose of this study was a comparison of conventional radiographic views with different CT reconstructions with 2 D and 3 D imaging to establish indications for additional CT diagnostics depending on the fractured parts. Methods In a prospective diagnostic study in two level 1 trauma centers, 44 patients with proximal humeral fractures were diagnosed with conventional X-rays (22 AP + axillary views, 22 AP + scapular Y-views and CT (multi-planar reconstruction (MPR and maximum intensity projection (MIP with 2 D and 3 D imaging. 3 observers assessed the technical image quality, the assessment of the relevant anatomical structures (2-sample-t-test and the percentage of the osseous overlap of the proximal humerus (Welch-test using a scoring system. The quality of the different diagnostic methods was assessed according to the number of fractured parts (Bonferroni-Holm adjustment. Results There was significantly more overlap of the fractured region on the scapular Y-views (mean 71.5%, range 45–90% than on axillary views (mean 56.2%, range 10.5–100%. CT-diagnostics allowed a significantly better assessment of the relevant structures than conventional diagnostics (p Conclusion Conventional X-rays with AP view and a high-quality axillary view are useful for primary diagnostics of the fracture and often but not always show a clear presentation of the relevant bony structures such as both tuberosities, the glenoid and humeral head. CT with thin slices technology and additional 3 D imaging provides always a clear presentation of the fractured region. Clinically, a CT should be performed – independently of the number of fractured parts – when the proximal humerus and the shoulder joint are not presented with sufficient X-ray-quality to establish a treatment plan.

  2. Cumulative Alendronate Dose and the Long-Term Absolute Risk of Subtrochanteric and Diaphyseal Femur Fractures: A Register-Based National Cohort Analysis

    DEFF Research Database (Denmark)

    Abrahamsen, Bo; Eiken, Pia Agnete; Eastell, Richard

    2010-01-01

    are currently the subject of a U.S. Food and Drug Administration review. Objective: Our objective was to examine the risk of subtrochanteric/diaphyseal femur fractures in long term users of alendronate. Design: We conducted an age- and gender-matched cohort study using national healthcare data. Patients...

  3. Triceps-sparing approach for open reduction and internal fixation of neglected displaced supracondylar and distal humeral fractures in children.

    Science.gov (United States)

    Rizk, Ahmed Shawkat

    2015-06-01

    Supracondylar humeral fractures are one of the most common skeletal injuries in children. In cases of displacement and instability, the standard procedure is early closed reduction and percutaneous Kirschner wire fixation. However, between 10 and 20 % of patients present late. According to the literature, patients with neglected fractures are those patients who presented for treatment after 14 days of injury. The delay is either due to lack of medical facilities or social and financial constraints. The neglected cases are often closed injuries with no vascular compromise. However, the elbow may still be tense and swollen with abrasions or crusts. In neglected cases, especially after early appearance of callus, there is no place for closed reduction and percutaneous pinning. Traditionally, distal humeral fractures have been managed with surgical approaches that disrupt the extensor mechanism with less satisfactory functional outcome due to triceps weakness and elbow stiffness. The aim of this study is to evaluate the outcome of delayed open reduction using the triceps-sparing approach and Kirschner wire fixation for treatment of neglected, displaced supracondylar and distal humeral fractures in children. This prospective study included 15 children who had neglected displaced supracondylar and distal humeral fractures. All patients were completely evaluated clinically and radiologically before intervention, after surgery and during the follow-up. The follow-up period ranged from 8 to 49 months, with a mean period of 17 months. Functional outcome was evaluated according to the Mayo Elbow Performance Index (MEPI) and Mark functional criteria. All fractures united in a mean duration of 7.2 weeks (range 5-10 weeks) with no secondary displacement or mal-union. Excellent results were found at the last follow-up in 13 of the 15 patients studied (86.66 %), while good results were found in two patients (13.33 %) according to the MEPI scale. According to the Mark

  4. Comparison of Primary Hip Spica with Crossed Retrograde Intramedullary Rush Pins for the Management of Diaphyseal Femur Fractures in Children: A Prospective, Randomized Study

    Directory of Open Access Journals (Sweden)

    Mohammad Ruhullah

    2013-12-01

    Conclusions: Intra-medullary crossed Rush pinning is an effective method of paediatric diaphyseal femur fracture fixation as compared to primary hip spica in terms of early weight bearing and restoration of normal anatomy.

  5. Osteosynthesis of medial humeral epicondyle fractures in children. 8-year follow-up of 33 cases

    DEFF Research Database (Denmark)

    Duun, P S; Ravn, Pernille; Hansen, L B

    1994-01-01

    33 children with a mean age of 12 (7-15) years had open reduction and osteosynthesis for a displaced fracture of the medial humeral epicondyle. 8 (2-15) years after the operation a clinical and radiographic examination was performed. 22/33 had a prominent scar. No patients had symptoms from...

  6. A new mini-invasive technique in treating pediatric diaphyseal forearm fractures by bioabsorbable elastic stable intramedullary nailing: a preliminary technical report.

    Science.gov (United States)

    Sinikumpu, J-J; Keränen, J; Haltia, A-M; Serlo, W; Merikanto, J

    2013-01-01

    Operative treatment is often indicated in unstable pediatric diaphyseal forearm fractures. Recently minimally invasive reduction and elastic stable intramedullary nailing have been of increasing interest, instead of open reduction and internal fixation with plates. There are several disadvantages of metallic intramedullary implants, such as soft-tissue irritation and a risk of disturbing later imaging. Thus, they are generally removed in later operations. We aimed to develop a new technique to stabilize pediatric forearm fractures by the bioabsorbable intramedullary nailing. We developed a new, two-stage mini-invasive surgical technique to stabilize the unstable diaphyseal fractures in children. The procedure is bioabsorbable elastic stable intramedullary nailing. Ultra-high-strength bioabsorbable intramedullary nails of poly(lactide-co-glycolide) were manufactured for our purpose. The material has been widely proven to be biocompatible and stable enough for fracture treatment as screws and pins. We have used the new technique in the unstable both-bone diaphyseal forearm fractures in children between the ages of 5 and 15 years. We report the technique and our clinical experience in the series of those three cases that have been followed up for at least 12 months. The present series has been randomized for the procedure instead for titanium elastic stable intramedullary nailing, and the series represents a part of ongoing randomized trial. The reported cases operated by the new technique referred good union in the fractured bones and acceptable alignment in the follow-up. Removal of the implants was not required. No troubles with the procedure or implant per se were noticed, indicating good feasibility. One high-energy refracture occurred half year after the primary trauma. Traditional titanium implants were used to control the refracture. We report our preliminary experience of a new surgical mini-invasive procedure to stabilize the unstable pediatric forearm shaft

  7. The female geriatric proximal humeral fracture: protagonist for straight antegrade nailing?

    Science.gov (United States)

    Lindtner, Richard A; Kralinger, Franz S; Kapferer, Sebastian; Hengg, Clemens; Wambacher, Markus; Euler, Simon A

    2017-10-01

    Straight antegrade humeral nailing (SAHN) has become a standard technique for the surgical fixation of proximal humeral fractures, which predominantly affect elderly females. The nail's proximal anchoring point has been demonstrated to be critical to ensure reliable fixation in osteoporotic bone and to prevent iatrogenic damage to the superior rotator cuff bony insertion. Anatomical variations of the proximal humerus, however, may preclude satisfactory anchoring of the nail's proximal end and may bare the risk of rotator cuff violation, even though the nail is inserted as recommended. The aim of this study was to evaluate the anatomical suitability of proximal humeri of geriatric females aged 75 years and older for SAHN. Specifically, we sought to assess the proportion of humeri not anatomically amenable to SAHN for proximal humeral fracture. A total of 303 proximal humeri of 241 females aged 75 years and older (mean age 84.5 ± 5.0 years; range 75-102 years) were analyzed for this study. Multiplanar two-dimensional reformations (true ap, true lateral, and axial) were reconstructed from shoulder computed tomography (CT) data sets. The straight antegrade nail's ideal entry point, "critical point" (CP), and critical distance (CD; distance between ideal entry point and CP) were determined. The rate of proximal humeri not anatomically suitable for SAHN (critical type) was assessed regarding proximal reaming diameters of currently available straight antegrade humeral nails. Overall, 35.6% (108/303) of all proximal humeri were found to be "critical types" (CD straight antegrade nails currently in use. Moreover, 43.2% (131/303) of the humeri were considered "critical types" with regard to the alternatively used larger proximal reaming diameter of 11.5 mm. Mean CD was 9.0 ± 1.7 mm (range 3.5-13.5 mm) and did not correlate with age (r = -0.04, P = 0.54). No significant differences in CD and rate of "critical types" were found between left and right humeri

  8. [Effectiveness comparison of suspension fixation plus hinged external fixator and double plate internal fixation in treatment of type C humeral intercondylar fractures].

    Science.gov (United States)

    Zhang, Jian; Lin, Xu; Zhong, Zeli; Wu, Chao; Tan, Lun

    2017-07-01

    To compare the effectiveness of suspension fixation plus hinged external fixator with double plate internal fixation in the treatment of type C humeral intercondylar fractures. Between January 2014 and April 2016, 30 patients with type C (Association for the Study of Internal Fixation, AO/ASIF) humeral intercondylar fractures were treated. Kirschner wire suspension fixation plus hinged external fixator was used in 14 cases (group A), and double plate internal fixation in 16 cases (group B). There was no significant difference in gender, age, injury cause, disease duration, injury side, and type of fracture between 2 groups ( P >0.05). There was no significant difference in operation time and hospitalization stay between 2 groups ( P >0.05). But the intraoperative blood loss in group A was significantly less than that in group B ( P internal fixation removal, the intraoperative blood loss, and VAS score at 1 day and 3 days after operation in group A were significant better than those in group B ( P external fixator and double plate internal fixation for the treatment of type C humeral intercondylar fractures have ideal outcome in elbow function. But the suspension fixation plus hinged external fixator is better than double plate internal fixation in intraoperative blood loss, postoperative VAS score, and time of internal fixation removal.

  9. Minimally Invasive Treatment of Displaced Proximal Humeral Fractures in Patients Older Than 70 Years Using the Humerusblock

    Directory of Open Access Journals (Sweden)

    Robert Bogner

    2016-01-01

    Full Text Available Background. Surgical treatment of proximal humeral fractures (PHF in osteoporotic bone of elderly patients is challenging. The aim of this retrospective study was to evaluate the clinical and radiological outcome after percutaneous reduction and internal fixation of osteoporotic PHF in geriatric patients using the semirigid Humerusblock device. Methods. In the study period from 2005 to 2010, 129 patients older than 70 years were enrolled in the study. After a mean follow-up of 23 months, a physical examination, using the Constant-Murley score and the VAS pain scale, was performed. Furthermore radiographs were taken to detect signs of malunion, nonunion, and avascular necrosis. Results. The recorded Constant-Murley score was 67.7 points (87.7% of the noninjured arm for two-part fractures, 67.9 points (90.8% for three-part fractures, and 43.0 points (56.7% for four-part fractures. In ten shoulders (7.8% loss of reduction and in four shoulders (3.1% nonunion were the reason for revision surgery. Avascular humeral head necrosis developed in eight patients (6.2%. Conclusions. In two- and three-part fractures postoperative results are promising. Sufficient ability for the activities of daily living was achieved. In four-part fractures the functional results were less satisfying regarding function and pain with a high postoperative complication rate. In those patients other treatment strategies should be considered. Study design. Therapeutic retrospective case series (evidence-based medicine (EBM level IV.

  10. [Vascular and neurological complications of supracondylar humeral fractures in children].

    Science.gov (United States)

    Masár, J

    2007-10-01

    The author reports two cases of pediatric patients with supracondylar humeral fractures complicated by concomitant vascular injury. One of the patients also presented with neurological symptoms from compression of the ulnar and median nerves. In the case of vascular injury only, it was necessary to resect a 1-cm segment of the brachial artery which was thrombosed due to intimal disruption. In the other case, surgery was not indicated immediately; however, liberation of the nervus ulnaris and nervus medianus was later required because of nerve compression by the scar and bone. The author considers the exact diagnosis, precise reduction and stable fixation of a fracture to be most important for a good outcome of treatment. Any associated vascular injury is indicated for surgery only after a thorough diagnostic consideration, and may not be needed in every case. The most decisive factor is the clinical presentation. Injury to the nerve system is indicated for surgical treatment at a later period, at 3 months post-injury at the earliest.

  11. Bone properties of the humeral head and resistance to screw cutout

    DEFF Research Database (Denmark)

    Frich, L. H.; Jensen, N. C.

    2014-01-01

    Surgical treatment of fractures involving the proximal humeral head is hampered by complications. Screw cutout is the major pitfall seen in connection with rigid plating. We have exploited a bony explanation for this phenomenon. Materials and Methods: We examined the convex surface of the humeral...... sectioning technique. Results: The bone strength and bone density correlated well and revealed large regional variations across the humeral head. Bone strength and stiffness of the trabecular bone came to a maximum in the most medial anterior and central parts of the humeral head, where strong textural...... screw directions will predictably place screws in areas of the humeral head comprising low density and low strength cancellous bone. New concepts of plates and plating techniques for the surgical treatment of complex fractures of the proximal humerus should take bone distribution, strength...

  12. "Floating arm" injury in a child with fractures of the proximal and distal parts of the humerus: a case report

    Directory of Open Access Journals (Sweden)

    Güven Melih

    2009-09-01

    Full Text Available Abstract Introduction Simultaneous supracondylar humerus fracture and ipsilateral fracture of the proximal humerus in children is rare. Case presentation A 10-year-old Turkish boy with an extension type supracondylar humerus fracture and ipsilateral fracture at the proximal metaphyseal-diaphyseal junction of the humerus was treated by closed reduction and percutaneous Kirschner wire fixation. Closed reduction was performed using a Kirschner wire as a "joystick" to manipulate the humeral shaft after some swelling occurred around the elbow and shoulder. Conclusion The combination of fractures at the proximal and distal parts of the humerus can be termed as "floating arm" injury. Initial treatment of this unusual injury should be focused on the supracondylar humerus fracture. However, closed reduction can be difficult to perform with the swelling around the elbow and shoulder. A temporary Kirschner wire can be used as a "joystick" to fix and reduce the fracture.

  13. [Manipulative reduction and small splint fixation combined with micromovement exercise for treatment of humeral shaft fractures].

    Science.gov (United States)

    Tang, Hao-chen; Xiang, Ming; Chen, Hang; Hu, Xiao-chuan; Yang, Guo-yong

    2016-01-01

    To investigate the therapeutic efficacy of bone-setting manipulative reduction and small splint fixation combined with micro-movement theory exercise for treatment of humeral shaft fractures. From March 2011 to February 2014, 64 cases of humeral shaft fractures were treated by bone-setting manipulative reduction and small splint fixation including 28 males and 36 females with an average age of 38.1 years old ranging from 22 to 67 years old. According to the classification of AO/OTA, there were 10 cases of type A1, 12 cases of type A2,11 cases of type A3,10 cases of type B1,12 cases of type B2, 7 cases of type B3, 2 cases of type C1, 1 case of type C2, 1 case of type C3. After close reduction early functional exercise performed according to micro-movement theory. All patients had no other parts of the fractures, neurovascular injury, and serious medical problems. Patients were followed up for fracture healing, shoulder and elbow joint function recovery, and curative effect. All patients were followed up from 10 to 12 months with an average of 10.3 months. Of them, 2 cases had a small amount of callus growth at 3 months after close reduction, so instead of operation; 2 cases appeared radial nerve symptoms after close reduction ,so instead of operation. Other patients were osseous healing, the time was 8 to 12 weeks with an average of 10.2 weeks. After osseous healing, according to Constant-Murley score system ,the average score was (93.5 ± 3.2) points, the result was excellent in 29 cases, good in 29 cases, fair in 6 cases, excellent and good rate was 90.3%; according to the Mayo score system, the average score was (93.7 ± 4.2) points, the result was excellent in 35 cases, good in 23 cases, fair in 6 cases, excellent and good rate was 91.9%. Bone-setting manipulative reduction and small splint fixation combined with micromovement theory exercise for treatment of humeral shaft fractures has advantage of positive effect, easy and inexpensive method, the treatment has

  14. Emergency or Delayed Surgical Treatment of Unstable Supracondylar Humeral Fractures in Children?

    Directory of Open Access Journals (Sweden)

    Stefanovic Branko

    2017-06-01

    Full Text Available Supracondylar humeral fractures (SCHF are the most common elbow fractures in children, representing 3% of all paediatric fractures. Treatment options for SCHF in children are based on the Gartland classification. Treatment of non-displaced fractures (type I is non-operative. Plaster immobilization for 3 to 4 weeks is recommended, depending on the age of the child and fracture healing. Treatments of displaced supracondylar fractures (type II and III of the humerus in children are still undefined in clinical practice. Because of divided opinions, the aim of this study was to evaluate whether delayed or immediate surgical treatment has an advantage in the treatment of supracondylar fractures in children. This is a prospective – retrospective clinical study. This study included 64 patients from 5 to 15 years old; 47 (73.4% were boys and 17 (26.6% were girls. The most common age range (59.4% in this study was 5-8 years old. All patients were diagnosed with supracondylar fractures at the Institute for Orthopaedic Surgery “Banjica”. We analysed 17 parameters, which were obtained either from direct patient interviews or from their medical history. All patients were divided into two groups with matched characteristics. Group I consisted of 26 patients who had immediate operations. Group II consisted of 38 patients who had delayed operations.

  15. Simulation-Based Educational Module Improves Intern and Medical Student Performance of Closed Reduction and Percutaneous Pinning of Pediatric Supracondylar Humeral Fractures.

    Science.gov (United States)

    Butler, Bennet A; Lawton, Cort D; Burgess, Jamie; Balderama, Earvin S; Barsness, Katherine A; Sarwark, John F

    2017-12-06

    Simulation-based education has been integrated into many orthopaedic residency programs to augment traditional teaching models. Here we describe the development and implementation of a combined didactic and simulation-based course for teaching medical students and interns how to properly perform a closed reduction and percutaneous pinning of a pediatric supracondylar humeral fracture. Subjects included in the study were either orthopaedic surgery interns or subinterns at our institution. Subjects all completed a combined didactic and simulation-based course on pediatric supracondylar humeral fractures. The first part of this course was an electronic (e)-learning module that the subjects could complete at home in approximately 40 minutes. The second part of the course was a 20-minute simulation-based skills learning session completed in the simulation center. Subject knowledge of closed reduction and percutaneous pinning of supracondylar humeral fractures was tested using a 30-question, multiple-choice, written test. Surgical skills were tested in the operating room or in a simulated operating room. Subject pre-intervention and post-intervention scores were compared to determine if and how much they had improved. A total of 21 subjects were tested. These subjects significantly improved their scores on both the written, multiple-choice test and skills test after completing the combined didactic and simulation module. Prior to the module, intern and subintern multiple-choice test scores were significantly worse than postgraduate year (PGY)-2 to PGY-5 resident scores (p < 0.01); after completion of the module, there was no significant difference in the multiple-choice test scores. After completing the module, there was no significant difference in skills test scores between interns and PGY-2 to PGY-5 residents. Both tests were validated using the scores obtained from PGY-2 to PGY-5 residents. Our combined didactic and simulation course significantly improved intern and

  16. [The Extended Deltoid-Split Approach for Plating Four-Part Proximal Humeral Fractures].

    Science.gov (United States)

    Schiffer, G; Sayar, A; Thelen, U

    2016-08-01

    The deltoideopectoral approach is established as the gold standard in the surgical treatment of proximal humeral fractures. As an alternative, we demonstrate the extended deltoid approach with an intraoperative video. A direct lateral incision is performed and the anterior parts of the axillary nerve are identified and preserved. In our experience, this approach allows improved visualisation of the greater tuberosity and easier positioning of locking plates. Clinically relevant neurological injuries cannot be seen in our patients or in the literature. Georg Thieme Verlag KG Stuttgart · New York.

  17. Stress fracture of the proximal humeral epiphysis in an elite junior badminton player.

    Science.gov (United States)

    Boyd, K T; Batt, M E

    1997-01-01

    An elite junior badminton player presented with a chronic painful dominant shoulder after an intense training course. An acute stress fracture to the proximal humeral epiphysis was found. Two-plane radiography will identify abnormalities of the growth plate but comparative films of the unaffected side may also be required to differentiate subtle changes. Rest with subsequent rehabilitation is the appropriate management of these injuries although ideally they should be subjected to primary prevention. Images Figure 1 Figure 2 PMID:9298564

  18. Treatment Results Of Diaphyseal Forearm Fractures With Dynamique Compression Plate A Retrospective study of 156 Cases.

    Directory of Open Access Journals (Sweden)

    Hassan BOUSSAKRI

    2015-12-01

    Full Text Available This retrospective study addresses a series of 156 cases of forearm fractures. These 156 cases were managed in the trauma-orthopedic department (B4 of Fez University Hospital, Morocco, from May 2008 till January 2013. The purpose of this study is to analyze epidemiological and clinical factors of diaphyseal forearm fractures and the results of their treatment with dynamic compression plate (DCP, as well as the complications and therapeutic errors of this surgical technique. The frequency of hospitalization in the trauma-orthopedic department was 3,96%. Ages ranged between 16 and 83, the average age was 32. 132 patients were male (85%. 90% were managed at the day of trauma. Traffic accidents were the most frequent cause in 52% patients. The fracture was in the left forearm in 65% of patients. 53% of fracture lines were in the middle third of the forearm. 38 fractures were open, and 30 were admitted for polytrauma. Osteosynthesis was performed with dynamic compression plate for all patients. In comparison with the literature, our series shows the predominance of young male patients, with traffic accidents being the cause. Osteosynthesis with dynamic compression plate remains the treatment of choice that provides satisfactory results if the accuracy in this technique was respected.

  19. Late Prosthetic Shoulder Hemiarthroplasty after Failed Management of Complex Proximal Humeral Fractures

    Directory of Open Access Journals (Sweden)

    A. Panagopoulos

    2013-01-01

    Full Text Available Background. The purpose of this study was to report our experience with shoulder hemiarthroplasty in the context of old trauma. Methods. 33 patients with failed treatment for a complex proximal humeral fracture underwent prosthetic hemiarthroplasty. There were 15 men and 18 women with a mean age of 58.1 years. The average period from initial treatment was 14.9 months. Sequelae included 11 malunions, 4 nonunions, 15 cases with avascular necrosis (AVN and 3 neglected posterior locked dislocations. Follow up investigation included radiological assessment and clinical evaluation using the Constant score and a visual analogue pain scale. Results. After a mean follow up of 82.5 months the median Constant score was 75.7 points, improved by 60% in comparison to preoperative values. Greater tuberosity displacement, large cuff tears and severe malunion were the factors most affected outcome. No cases of stem loosening or severe migration were noted. 60% of the patients were able to do activities up to shoulder level compared with 24% before reconstruction. Conclusions. Late shoulder hemiarthroplasty is technically difficult and the results are inferior to those reported for acute humeral head replacement, nonetheless remains a satisfactory reconstructive option when primary treatment fails.

  20. Interventions for treating proximal humeral fractures in adults.

    Science.gov (United States)

    Handoll, Helen H G; Ollivere, Benjamin J; Rollins, Katie E

    2012-12-12

    Fractures of the proximal humerus are common injuries. The management, including surgical intervention, of these fractures varies widely. This is an update of a Cochrane review first published in 2001 and last updated in 2010. To review the evidence supporting the various treatment and rehabilitation interventions for proximal humeral fractures. We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register, the Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE and other databases, and bibliographies of trial reports. The full search ended in January 2012. All randomised controlled trials pertinent to the management of proximal humeral fractures in adults were selected. Two people performed independent study selection, risk of bias assessment and data extraction. Only limited meta-analysis was performed. Twenty-three small randomised trials with a total of 1238 participants were included. Bias in these trials could not be ruled out. Additionally there is a need for caution in interpreting the results of these small trials, which generally do not provide sufficient evidence to conclude that any non-statistically significant finding is 'evidence of no effect'.Eight trials evaluated conservative treatment. One trial found an arm sling was generally more comfortable than a less commonly used body bandage. There was some evidence that 'immediate' physiotherapy compared with that delayed until after three weeks of immobilisation resulted in less pain and potentially better recovery in people with undisplaced or other stable fractures. Similarly, there was evidence that mobilisation at one week instead of three weeks alleviated short term pain without compromising long term outcome. Two trials provided some evidence that unsupervised patients could generally achieve a satisfactory outcome when given sufficient instruction for an adequate self-directed exercise programme.Six heterogeneous trials, involving a total of 270 participants with

  1. Humeral stress remodelling locations differ in Thoroughbred racehorses training and racing on dirt compared to synthetic racetrack surfaces.

    Science.gov (United States)

    Dimock, A N; Hoffman, K D; Puchalski, S M; Stover, S M

    2013-03-01

    Veterinarians have observed a putative change in the location of humeral stress remodelling in Thoroughbred racehorses with change from dirt to synthetic racetrack surfaces. To determine whether the location and severity of humeral stress remodelling differs between Thoroughbred racehorses exercising on dirt and synthetic racetrack surfaces, the potential significance of different locations of stress remodelling, and the potential usefulness of scintigraphy for prevention of complete humeral fracture. Scintigraphic images of humeri from 841 Thoroughbred racehorses at 3 racetracks during 2 years before and after conversion from dirt to synthetic surfaces were evaluated for location and severity of lesions. The effects of surface on lesion distributions were examined using Chi-square or Fisher's exact tests. Archived fractured humeri were examined to determine the location and severity of stress remodelling associated with complete fracture. Databases were queried to determine whether racehorses with scintigraphic lesions suffered humeral fracture and whether racehorses with a complete humeral fracture had had a scintigraphic examination. Horses at synthetic racetracks had a greater proportion of distal humeral lesions, whereas horses at dirt racetracks had a greater proportion of caudoproximal lesions (Pdirt surfaces, and, by inference, for horses examined using scintigraphy. © 2012 EVJ Ltd.

  2. Distal humeral physeal injuries in child abuse: MR imaging and ultrasonography findings

    International Nuclear Information System (INIS)

    Nimkin, K.; Kleinman, P.K.; Teeger, S.; Spevak, M.R.

    1995-01-01

    Distal humeral physeal injuries, in particular, fracture-separation of the distal humeral epiphysis, can be seen in abused infants. Detection of physeal injury in an infant of toddler may indicate the possibility of unsuspected abuse, particularly when an appropriate history explaining the circumstance of the fracture is lacking. In addition, the extent of injury can be difficult to characterize on plain radiographs. Ultrasonography (US) and MR imaging (MRI) may be of value in diagnosis and may obviate the need for intraoperative arthrography. We present MRI findings in three abused children with distal humeral physeal injuries. Sonographic correlation is also presented in one case. (orig.)

  3. Distal humeral physeal injuries in child abuse: MR imaging and ultrasonography findings

    Energy Technology Data Exchange (ETDEWEB)

    Nimkin, K. [Dept. of Radiology, Univ. of Massachusetts, Medical Center, Worcester, MA (United States); Kleinman, P.K. [Dept. of Radiology, Univ. of Massachusetts, Medical Center, Worcester, MA (United States); Teeger, S. [Dept. of Radiology, Univ. of Massachusetts, Medical Center, Worcester, MA (United States); Spevak, M.R. [Dept. of Radiology, Univ. of Massachusetts, Medical Center, Worcester, MA (United States)

    1995-09-01

    Distal humeral physeal injuries, in particular, fracture-separation of the distal humeral epiphysis, can be seen in abused infants. Detection of physeal injury in an infant of toddler may indicate the possibility of unsuspected abuse, particularly when an appropriate history explaining the circumstance of the fracture is lacking. In addition, the extent of injury can be difficult to characterize on plain radiographs. Ultrasonography (US) and MR imaging (MRI) may be of value in diagnosis and may obviate the need for intraoperative arthrography. We present MRI findings in three abused children with distal humeral physeal injuries. Sonographic correlation is also presented in one case. (orig.)

  4. Outcome of limb reconstruction system in open tibial diaphyseal fractures

    Directory of Open Access Journals (Sweden)

    Anand Ajmera

    2015-01-01

    Full Text Available Background: Management of open tibial diaphyseal fractures with bone loss is a matter of debate. The treatment options range from external fixators, nailing, ring fixators or grafting with or without plastic reconstruction. All the procedures have their own set of complications, like acute docking problems, shortening, difficulty in soft tissue management, chronic infection, increased morbidity, multiple surgeries, longer hospital stay, mal union, nonunion and higher patient dissatisfaction. We evaluated the outcome of the limb reconstruction system (LRS in the treatment of open fractures of tibial diaphysis with bone loss as a definative mode of treatment to achieve union, as well as limb lengthening, simultaneously. Materials and Methods: Thirty open fractures of tibial diaphysis with bone loss of at least 4 cm or more with a mean age 32.5 years were treated by using the LRS after debridement. Distraction osteogenesis at rate of 1 mm/day was done away from the fracture site to maintain the limb length. On the approximation of fracture ends, the dynamized LRS was left for further 15-20 weeks and patient was mobilized with weight bearing to achieve union. Functional assessment was done by Association for the Study and Application of the Methods of Illizarov (ASAMI criteria. Results: Mean followup period was 15 months. The mean bone loss was 5.5 cm (range 4-9 cm. The mean duration of bone transport was 13 weeks (range 8-30 weeks with a mean time for LRS in place was 44 weeks (range 24-51 weeks. The mean implant index was 56.4 days/cm. Mean union time was 52 weeks (range 31-60 weeks with mean union index of 74.5 days/cm. Bony results as per the ASAMI scoring were excellent in 76% (19/25, good in 12% (3/25 and fair in 4% (1/25 with union in all except 2 patients, which showed poor results (8% with only 2 patients having leg length discrepancy more than 2.5 cm. Functional results were excellent in 84% (21/25, good in 8% (2/25, fair in 8% (2/25. Pin

  5. Outcome of limb reconstruction system in open tibial diaphyseal fractures.

    Science.gov (United States)

    Ajmera, Anand; Verma, Ankit; Agrawal, Mukul; Jain, Saurabh; Mukherjee, Arunangshu

    2015-01-01

    Management of open tibial diaphyseal fractures with bone loss is a matter of debate. The treatment options range from external fixators, nailing, ring fixators or grafting with or without plastic reconstruction. All the procedures have their own set of complications, like acute docking problems, shortening, difficulty in soft tissue management, chronic infection, increased morbidity, multiple surgeries, longer hospital stay, mal union, nonunion and higher patient dissatisfaction. We evaluated the outcome of the limb reconstruction system (LRS) in the treatment of open fractures of tibial diaphysis with bone loss as a definative mode of treatment to achieve union, as well as limb lengthening, simultaneously. Thirty open fractures of tibial diaphysis with bone loss of at least 4 cm or more with a mean age 32.5 years were treated by using the LRS after debridement. Distraction osteogenesis at rate of 1 mm/day was done away from the fracture site to maintain the limb length. On the approximation of fracture ends, the dynamized LRS was left for further 15-20 weeks and patient was mobilized with weight bearing to achieve union. Functional assessment was done by Association for the Study and Application of the Methods of Illizarov (ASAMI) criteria. Mean followup period was 15 months. The mean bone loss was 5.5 cm (range 4-9 cm). The mean duration of bone transport was 13 weeks (range 8-30 weeks) with a mean time for LRS in place was 44 weeks (range 24-51 weeks). The mean implant index was 56.4 days/cm. Mean union time was 52 weeks (range 31-60 weeks) with mean union index of 74.5 days/cm. Bony results as per the ASAMI scoring were excellent in 76% (19/25), good in 12% (3/25) and fair in 4% (1/25) with union in all except 2 patients, which showed poor results (8%) with only 2 patients having leg length discrepancy more than 2.5 cm. Functional results were excellent in 84% (21/25), good in 8% (2/25), fair in 8% (2/25). Pin tract infection was seen in 5 cases, out of which 4

  6. Fluoroscopically guided closed reduction and internal fixation of fractures of the lateral portion of the humeral condyle: prospective clinical study of the technique and results in ten dogs.

    Science.gov (United States)

    Cook, J L; Tomlinson, J L; Reed, A L

    1999-01-01

    To report a technique for fluoroscopically guided closed reduction with internal fixation of fractures of the lateral portion of the humeral condyle (FLHC) and determine the long-term results in 10 clinical cases. Prospective clinical case study. Ten dogs with 11 fractures. Fractures of the lateral portion of the humeral condyle were stabilized with transcondylar screws and Kirschner wires. Closed reduction and implant placement were achieved using intraoperative fluoroscopic guidance. After fracture repair, postoperative radiographs were evaluated for articular alignment and implant placement. Dogs were evaluated after surgery by means of lameness scores, elbow range of motion (ROM), radiographic assessment, and owner evaluation of function. Postoperative reduction was considered anatomic in 6 fractures with all other fractures having ROM values between affected and unaffected elbows. All of the dogs in this study regained 90-100% of full function, based on owner assessment. Fluoroscopic guidance for closed reduction and internal fixation of FLHC in dogs is an effective technique.

  7. Intraobserver and interobserver reliability of recategorized Neer classification in differentiating 2-part surgical neck fractures from multi-fragmented proximal humeral fractures in 116 patients

    DEFF Research Database (Denmark)

    Sumrein, Bakir O; Mattila, Ville M; Lepola, Vesa

    2018-01-01

    BACKGROUND: Optimal fracture classification should be simple and reproducible and should guide treatment. For proximal humeral fractures, the Neer classification is commonly used. However, intraobserver and interobserver reliability of the Neer classification has been shown to be poor. In clinical...... for interobserver reliability showed substantial correlation (0.61-0.73) and was as follows: 0.73 for radiographs alone, 0.61 for CT scans alone, and 0.72 for radiographs and CT scans viewed together. After 24 weeks, the process was repeated and intraobserver reliability was calculated.The κ coefficient...... for intraobserver reliability showed substantial correlation (0.62-0.75) and was as follows: 0.62 for radiographs alone, 0.64 for CT scans alone, and 0.75 for radiographs and CT scans viewed together. CONCLUSION: Clinicians were able to differentiate 2-part surgical neck fractures from multi-fragmented fractures...

  8. Osteosynthesis of the diaphysis of the humeral with plates - Series of cases

    International Nuclear Information System (INIS)

    Reyes Reyes, Claudia Juliana; Valencia Chamorro, Martha Patricia; Garcia Gonzalez, Luis Alejandro

    2005-01-01

    Humeral shaft fractures may be treated in various ways. When surgical treatment is preferred, both plates and intramedullary nails are available and feasible options; the latter have recently gained popularity. We present the results of a case series of humeral fractures treated by open reduction and plate fixation with DCP plates, the results are described in terms of union rate, function, satisfaction, and complications. Thirty patients were included, with ages from 18 to 74 years, with mean follow-up time of 35 months; twelve patients were treated for delayed or non-union after orthopedic treatment. There was one case of nonunion, and one of iatrogenic neurapraxia of the radial nerve. Mobility and strength were excellent. All patients reported to be satisfied with the treatment and its result. We discuss that plate fixation for humeral shaft fractures is a predictable choice, with low complication rate and high union rate

  9. Fracture of an unossified humeral medial epicondyle: use of magnetic resonance imaging for diagnosis

    International Nuclear Information System (INIS)

    Tanabe, Katsuhisa; Miyamoto, Nao

    2016-01-01

    Fracture of the humeral medial epicondyle is a relatively common injury in children. Surgery is a good option for treatment, but correct diagnosis is important. Most fractures occur after the ossification of the medial epicondylar apophysis. If a fracture occurs before the ossification of the medial epicondyle, it is undetectable by radiographs. Here we report a case of an unossified medial epicondyle fracture of the humerus. A 9-year-old boy had persistent pain in the medial side of the right elbow after a fall. Despite his pain, he could move his injured elbow with a range from 60 to 90 . Radiographs and computed tomography showed neither fracture nor dislocation in the injured elbow, and soft tissue swelling was the only finding. Neither the trochlea nor the medial epicondyle was ossified. Magnetic resonance imaging showed that the medial epicondyle was separated from the medial metaphysis and displaced. This clear finding led us to surgical fixation. Under general anesthesia, valgus stress showed gross instability of the injured elbow. Two years after the operation, he had no complaints and could play sports with the same range of motion as the left elbow. It is important to keep in mind that medial epicondylar fractures may be hidden in a normal radiograph before the ossification of the medial epicondylar apophysis. (orig.)

  10. Fracture of an unossified humeral medial epicondyle: use of magnetic resonance imaging for diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Tanabe, Katsuhisa; Miyamoto, Nao [Nishinomiya Municipal Central Hospital, Department of Orthopaedic Surgery, Nishinomiya (Japan)

    2016-10-15

    Fracture of the humeral medial epicondyle is a relatively common injury in children. Surgery is a good option for treatment, but correct diagnosis is important. Most fractures occur after the ossification of the medial epicondylar apophysis. If a fracture occurs before the ossification of the medial epicondyle, it is undetectable by radiographs. Here we report a case of an unossified medial epicondyle fracture of the humerus. A 9-year-old boy had persistent pain in the medial side of the right elbow after a fall. Despite his pain, he could move his injured elbow with a range from 60 to 90 . Radiographs and computed tomography showed neither fracture nor dislocation in the injured elbow, and soft tissue swelling was the only finding. Neither the trochlea nor the medial epicondyle was ossified. Magnetic resonance imaging showed that the medial epicondyle was separated from the medial metaphysis and displaced. This clear finding led us to surgical fixation. Under general anesthesia, valgus stress showed gross instability of the injured elbow. Two years after the operation, he had no complaints and could play sports with the same range of motion as the left elbow. It is important to keep in mind that medial epicondylar fractures may be hidden in a normal radiograph before the ossification of the medial epicondylar apophysis. (orig.)

  11. Medial Calcar Support and Radiographic Outcomes of Plate Fixation for Proximal Humeral Fractures

    Directory of Open Access Journals (Sweden)

    Shih-Jie Lin

    2015-01-01

    Full Text Available Plate fixation remains one of the most popular surgical procedures for treating proximal humeral fractures (PHFx; however, substantial rates of complications have been reported in the literature. The objectives of the study were to examine how medial calcar support (MCS affects the radiographic outcomes and to determine the prognostic factors predicting treatment failure. We performed a retrospective cohort study of 89 adult patients who had PHFx and were treated with plate fixation at our institution in 2007–2011. The enrolled patients were separated into two groups according to disruption of medial calcar. Our results revealed an increased rate of poor radiographic outcomes in patients with disrupted medial calcar. Osteonecrosis of the humeral head and redisplacement were the two radiographic outcomes which had a positive causality with disruption of medial calcar (P=0.008 and 0.050, resp.. Deficient medial calcar, inadequate reduction, diabetes mellitus, chronic kidney disease, and chronic liver disease were all significant predictors for the development of osteonecrosis in patients after PHFx surgery. Inadequate reduction was also a predictor for redisplacement. We confirmed that the restoration of medial calcar as well as comorbid conditions plays key roles in treatment of patients having PHFx with disrupted medial calcar.

  12. A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

    Directory of Open Access Journals (Sweden)

    Prakash Jayakumar

    2015-04-01

    Full Text Available Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking screw, which must also avoid the olecranon, coronoid, and radial fossae. We describe 3 patients (ages 27, 49, and 73 years with a bicolumnar fracture of the distal humerus where very short distal locking screws were used. Intra-articular screw placement was avoided but loss of fixation occurred in two patients and a third was treated with a prolonged period of immobilization. We postulate that fixed-angle screw trajectories may make it difficult for the surgeon to place screws of adequate length in this anatomically confined region, and may lead to insufficient distal fixation. Surgical tactics should include placement of as many screws as possible into the distal fragment, as long as possible, and that each screw pass through a plate without necessarily locking in.

  13. A Cost-Effectiveness Analysis of Reverse Total Shoulder Arthroplasty versus Hemiarthroplasty for the Management of Complex Proximal Humeral Fractures in the Elderly.

    Science.gov (United States)

    Osterhoff, Georg; O'Hara, Nathan N; D'Cruz, Jennifer; Sprague, Sheila A; Bansback, Nick; Evaniew, Nathan; Slobogean, Gerard P

    2017-03-01

    There is ongoing debate regarding the optimal surgical treatment of complex proximal humeral fractures in elderly patients. To evaluate the cost-effectiveness of reverse total shoulder arthroplasty (RTSA) compared with hemiarthroplasty (HA) in the management of complex proximal humeral fractures, using a cost-utility analysis. On the basis of data from published literature, a cost-utility analysis was conducted using decision tree and Markov modeling. A single-payer perspective, with a willingness-to-pay (WTP) threshold of Can$50,000 (Canadian dollars), and a lifetime time horizon were used. The incremental cost-effectiveness ratio (ICER) was used as the study's primary outcome measure. In comparison with HA, the incremental cost per quality-adjusted life-year gained for RTSA was Can$13,679. One-way sensitivity analysis revealed the model to be sensitive to the RTSA implant cost and the RTSA procedural cost. The ICER of Can$13,679 is well below the WTP threshold of Can$50,000, and probabilistic sensitivity analysis demonstrated that 92.6% of model simulations favored RTSA. Our economic analysis found that RTSA for the treatment of complex proximal humeral fractures in the elderly is the preferred economic strategy when compared with HA. The ICER of RTSA is well below standard WTP thresholds, and its estimate of cost-effectiveness is similar to other highly successful orthopedic strategies such as total hip arthroplasty for the treatment of hip arthritis. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  14. Displaced humeral lateral condyle fractures in children: should we bury the pins?

    Science.gov (United States)

    Das De, Soumen; Bae, Donald S; Waters, Peter M

    2012-09-01

    The purpose of this investigation was to determine if leaving Kirschner wires exposed is more cost-effective than burying them subcutaneously after open reduction and internal fixation (ORIF) of humeral lateral condyle fractures. A retrospective cohort study of all lateral condyle fractures treated over a 10-year period at a single institution was performed. Data on surgical technique, fracture healing, and complications were analyzed, as well as treatment costs. A decision analysis model was then constructed to compare the strategies of leaving the pins exposed versus buried. Finally, sensitivity analyses were performed, assessing cost-effectiveness when infection rates and costs of treating deep infections were varied. A total of 235 children with displaced fractures were treated with ORIF using Kirschner wires. Pins were left exposed in 41 cases (17.4%) and buried in 194 cases (82.6%); the age, sex, injury mechanisms, and fracture patterns were similar in both the groups. The median time to removal of implants was shorter with exposed versus buried pins (4 vs. 6 wk, Pfracture union or loss of reduction rates. The rate of superficial infection was higher with exposed pins (9.8% vs. 3.1%), but this was not statistically significant (P=0.076). There were no deep infections with exposed pins, whereas the rate of deep infection was 0.5% with buried pins (P=1.00). Buried pins were associated with additional complications, including symptomatic implants (7.2%); pins protruding through the skin (16%); internal pin migration necessitating additional surgery (1%); and skin necrosis (1%). The decision analysis revealed that leaving pins exposed resulted in an average cost savings of $3442 per patient. This strategy remained cost-effective even when infection rates with exposed pins approached 40%. Leaving the pins exposed after ORIF of lateral condyle fractures is safe and more cost-effective than burying the pins subcutaneously. Retrospective cohort study (level III).

  15. Placement of the stemless humeral component in the Total Evolutive Shoulder System (TESS).

    Science.gov (United States)

    Geurts, Ghislain F; van Riet, Roger P; Jansen, Nick; Declercq, Geert

    2010-12-01

    Humeral implant design in shoulder arthroplasty has evolved over the years. The third generation shoulder prostheses have an anatomic humeral stem that replicates the 3-dimensional parameters of the proximal humerus. The overall complication rate has decreased as a result of these changes in implant design. In contrast, the rate of periprosthetic humeral fractures has increased. To avoid stem-related complications while retaining the advantages of the third generation of shoulder implants, the stemless total evolutive shoulder system has been developed. The indications, the surgical technique, and the complications of this humeral implant in shoulder arthroplasty will be described.

  16. Trends in incidence rate, health care consumption, and costs for patients admitted with a humeral fracture in The Netherlands between 1986 and 2012

    NARCIS (Netherlands)

    K.C. Mahabier (Kiran); D. den Hartog (Dennis); M.J.M. Panneman (Martien); J.R. van Veldhuizen (Joyce); S. Polinder (Suzanne); M.H.J. Verhofstad (Michiel); E.M.M. van Lieshout (Esther)

    2015-01-01

    textabstractIntroduction: This study aimed to examine long-term population-based trends in the incidence rate of patients with a humeral fracture admitted to a hospital in the Netherlands from 1986 to 2012 and to give a detailed overview of the health care consumption and productivity loss with

  17. Surgical management for displaced pediatric proximal humeral fractures: a cost analysis.

    Science.gov (United States)

    Shore, Benjamin J; Hedequist, Daniel J; Miller, Patricia E; Waters, Peter M; Bae, Donald S

    2015-02-01

    The purpose of this investigation was to determine which of the following methods of fixation, percutaneous pinning (PP) or intramedullary nailing (IMN), was more cost-effective in the treatment of displaced pediatric proximal humeral fractures (PPHF). A retrospective cohort of surgically treated PPHF over a 12-year period at a single institution was performed. A decision analysis model was constructed to compare three surgical strategies: IMN versus percutaneous pinning leaving the pins exposed (PPE) versus leaving the pins buried (PPB). Finally, sensitivity analyses were performed, assessing the cost-effectiveness of each technique when infection rates and cost of deep infections were varied. A total of 84 patients with displaced PPHF underwent surgical stabilization. A total of 35 cases were treated with IMN, 32 with PPE, and 17 with PPB. The age, sex, and preoperative fracture angulation were similar across all groups. A greater percentage of open reduction was seen in the IMN and PPB groups (p = 0.03), while a higher proportion of physeal injury was seen in the PPE group (p = 0.02). Surgical time and estimated blood loss was higher in the IMN group (p exposed implants approached 55 %. Leaving pins exposed after surgical fixation of PPHF is more cost-effective than either burying pins or using intramedullary fixation.

  18. Implant failure in lower limb long bone diaphyseal fractures at a tertiary hospital in Ile- Ife. Nigeria.

    Science.gov (United States)

    Esan, O; Ikem, I C; Orimolade, E A; Esan, O T

    2014-06-01

    This included determining aetiology of failure and comparing the failure rate in implant fixations using solid intramedullary nail and DCP. A retrospective study conducted at the Orthopaedic Department, Obafemi Awolowo University Teaching Hospital, Ile-Ife,Nigeria. Records of all operated cases of lower limb long bone diaphyseal fractures including those with failed fixations from August 2006-July 2011 were reviewed. Data retrieved included type of implant used, aetiology and characteristics of Implant failure. Data were analysed using SPSS version 16. Frequency distribution of the variables of interest was done. Difference in failure rate of intramedullary nail versus DCP was tested using chi-square. Statistical significance was inferred at pfractures and met inclusion criteria, of which 135 had intramedullary nail fixation and 86 had DCP. The rate of implant failure in intramedullary nail was 1.5% while it was 5.8% in patients with DCP (p=0.113; 0R=4.10; 95% CI=0.65- 43.77). Implant fracture was the commonest type of failure seen (100% versus 60%) and non union was the commonest cause of failure seen (50% versus 40%) in the intramedullary nailing and DCP groups respectively. The likelihood of a failed implant is higher in fixations done with DCP compared with intramedullary nail though the difference was not statistically significant. Commonest reason for failure in both groups was non-union. Findings from this study may guide surgeons in choice of implant in the management of long bone fractures.

  19. Mismatch analysis of humeral nailing. Antegrade versus retrograde insertion

    International Nuclear Information System (INIS)

    Mahaisavariya, B.; Jiamwatthanachai, P.; Aroonjarattham, P.; Aroonjarattham, K.; Wongcumchang, M.; Sitthiseripratip, K.

    2011-01-01

    Closed humeral nailing is now considered an alternative treatment for humeral-shaft fracture. The nail can be inserted with either the antegrade or retrograde method. We investigated and compared the problem of geometric mismatch of the humeral nail to the humerus between the two methods of insertion. The study was performed using virtual simulation based on computed tomography (CT) data of 76 Thai cadaveric humeri and the commonly used Russell-Taylor humeral nail 8 mm in diameter and 220 mm long. Mismatch of the nail to the intact humerus was analyzed and compared between the antegrade and retrograde nailing approaches. The results showed: the diameter of the medullary canal averaged 7.9-13.8 mm; the minimal reaming diameter to accommodate virtual nail insertion averaged 8.8-14.8 mm for the antegrade and 8.8-29.3 mm for the retrograde approach; the minimal reaming thickness of the inner cortex averaged 0.1-1.5 mm for the antegrade and 0.1-9.9 mm for the retrograde approach; the percentages of cortical bone removed prior to nail insertion were 3.8-107.1% and 3.8-1,287.6% for the antegrade and retrograde approaches, respectively; the eccentricity of the nail-medullary canal center were 0.4-3.4 and 0.4-10.6 mm for the antegrade and retrograde approaches, respectively. Less mismatching occurred with antegrade nailing than with the retrograde approach. Retrograde nailing requires excessive reaming at the distal part of the humerus to accommodate nail insertion. This may create bone weakness and the risk of supracondylar fracture. (author)

  20. Age-related variation in limb bone diaphyseal structure among Inuit foragers from Point Hope, northern Alaska.

    Science.gov (United States)

    Wallace, I J; Nesbitt, A; Mongle, C; Gould, E S; Grine, F E

    2014-01-01

    Age-related deterioration of limb bone diaphyseal structure is documented among precontact Inuit foragers from northern Alaska. These findings challenge the concept that bone loss and fracture susceptibility among modern Inuit stem from their transition away from a physically demanding traditional lifestyle toward a more sedentary Western lifestyle. Skeletal fragility is rare among foragers and other traditional-living societies, likely due to their high physical activity levels. Among modern Inuit, however, severe bone loss and fractures are apparently common. This is possibly because of recent Western influences and increasing sedentism. To determine whether compromised bone structure and strength among the Inuit are indeed aberrant for a traditional-living group, data were collected on age-related variation in limb bone diaphyseal structure from a group predating Western influences. Skeletons of 184 adults were analyzed from the Point Hope archaeological site. Mid-diaphyseal structure was measured in the humerus, radius, ulna, femur, and tibia using CT. Structural differences were assessed between young, middle-aged, and old individuals. In all bones examined, both females and males exhibited significant age-related reductions in bone quantity. With few exceptions, total bone (periosteal) area did not significantly increase between young and old age in either sex, nor did geometric components of bending rigidity (second moments of area). While the physically demanding lifestyles of certain traditional-living groups may protect against bone loss and fracture susceptibility, this is not the case among the Inuit. It remains possible, however, that Western characteristics of the modern Inuit lifestyle exacerbate age-related skeletal deterioration.

  1. Atypical subtrochanteric and diaphyseal femoral fractures

    DEFF Research Database (Denmark)

    Shane, Elizabeth; Burr, David; Abrahamsen, Bo

    2014-01-01

    Bisphosphonates (BPs) and denosumab reduce the risk of spine and nonspine fractures. Atypical femur fractures (AFFs) located in the subtrochanteric region and diaphysis of the femur have been reported in patients taking BPs and in patients on denosumab, but they also occur in patients with no exp......Bisphosphonates (BPs) and denosumab reduce the risk of spine and nonspine fractures. Atypical femur fractures (AFFs) located in the subtrochanteric region and diaphysis of the femur have been reported in patients taking BPs and in patients on denosumab, but they also occur in patients...... with no exposure to these drugs. In this report, we review studies on the epidemiology, pathogenesis, and medical management of AFFs, published since 2010. This newer evidence suggests that AFFs are stress or insufficiency fractures. The original case definition was revised to highlight radiographic features...... a minor to a major feature. The association with specific diseases and drug exposures was removed from the minor features, because it was considered that these associations should be sought rather than be included in the case definition. Studies with radiographic review consistently report significant...

  2. FRACTURE SHAFT HUMERUS: INTERLOCKING

    Directory of Open Access Journals (Sweden)

    Deepak Kaladagi

    2014-12-01

    Full Text Available BACKGROUND: The incidence of humeral fracture has significantly increased during the present years due to the population growth and road traffic, domestic, industrial, automobile accidents & disasters like tsunami, earthquakes, head-on collisions, polytrauma etc. In order to achieve a stable fixation followed by early mobilization, numerous surgical implants have been devised. PURPOSE: The purpose of this study is to analyze the results of intramedullary fixation of proximal 2/3rd humeral shaft fractures using an unreamed interlocking intramedullary nail. INTRODUCTION: In 40 skeletally matured patients with fracture shaft of humerus admitted in our hospital, we used unreamed antegrade interlocking nails. MATERIAL: We carried out a prospective analysis of 40 patients randomly selected between 2001 to 2014 who were operated at JNMC Belgaum, MMC Mysore & Navodaya Medical College, Raichur. All cases were either RTAs, Domestic, Industrial, automobile accidents & also other modes of injury. METHOD: Routine investigations with pre-anaesthetic check-up & good quality X-rays of both sides of humerus was taken. Time of surgery ranged from 5-10 days from the time of admission. Only upper 1/3rd & middle 1/3rd humeral shaft fractures were included in the study. In all the cases antegrade locked unreamed humeral nails were inserted under C-arm. Patient was placed in supine position & the shoulder was kept elevated by placing a sandbag under the scapula. In all patients incision taken from tip of acromion to 3cm over deltoid longitudinally. Postoperatively sling applied with wrist & shoulder movements started after 24 hours. All the patients ranged between the age of 21-50 years. RESULTS: Total 40 patients were operated. Maximum fracture site were in the middle third- 76%, 14% upper 1/3rd. All 40 patients achieved union. The average time of union was 8-10 weeks. All patients regained full range of movements except in few cases, where there was shoulder

  3. Locking plate fixation for proximal humerus fractures.

    LENUS (Irish Health Repository)

    Burke, Neil G

    2012-02-01

    Locking plates are increasingly used to surgically treat proximal humerus fractures. Knowledge of the bone quality of the proximal humerus is important. Studies have shown the medial and dorsal aspects of the proximal humeral head to have the highest bone strength, and this should be exploited by fixation techniques, particularly in elderly patients with osteoporosis. The goals of surgery for proximal humeral fractures should involve minimal soft tissue dissection and achieve anatomic reduction of the head complex with sufficient stability to allow for early shoulder mobilization. This article reviews various treatment options, in particular locking plate fixation. Locking plate fixation is associated with a high complication rate, such as avascular necrosis (7.9%), screw cutout (11.6%), and revision surgery (13.7%). These complications are frequently due to the varus deformation of the humeral head. Strategic screw placement in the humeral head would minimize the possibility of loss of fracture reduction and potential hardware complications. Locking plate fixation is a good surgical option for the management of proximal humerus fractures. Complications can be avoided by using better bone stock and by careful screw placement in the humeral head.

  4. Diaphyseal medullary stenosis (sclerosis) with bone malignancy (malignant fibrous histiocytoma): hardcastle syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Norton, K.I. [Department of Radiology, Box 1234, Mount Sinai Hospital and Mount Sinai School of Medicine, City University of New York, One Gustave L. Levy Place, New York, NY 10029-6574 (United States)]|[Department of Pediatrics, Mount Sinai Hospital, New York, New York (United States); Wagreich, J.M. [Department of Radiology, Box 1234, Mount Sinai Hospital and Mount Sinai School of Medicine, City University of New York, One Gustave L. Levy Place, New York, NY 10029-6574 (United States); Granowetter, L. [Division of Pediatric Hematology-Oncology, Mount Sinai Hospital New York, New York (United States); Martignetti, J.A. [Department of Pediatrics, Mount Sinai Hospital, New York, New York (United States)

    1996-09-01

    Hardcastle syndrome is a rare, autosomally dominant inherited skeletal dysplasia, characterized by diaphyseal sclerosis, medullary stenosis, pathological fractures, bony infarction, and malignant transformation. A 19-year-old proband is presented and discussed, adding a fourth family to the world literature. Radiographic screening of family members is suggested from puberty onward. Thallium scanning is proposed as a more tumor-sensitive screening agent in affected individuals. (orig.). With 2 figs.

  5. Humeral windows in revision total elbow arthroplasty.

    Science.gov (United States)

    Peach, Chris A; Salama, Amir; Stanley, David

    2016-04-01

    The use of cortical windows for revision elbow arthroplasty has not previously been widely reported. Their use aids safe revision of a well fixed humeral prosthesis and can be used in the setting of dislocation, periprosthetic fracture or aseptic loosening of the ulnar component. We describe our technique and results of cortical windows in the distal humerus for revision elbow arthroplasty surgery.

  6. Surgical management of complete diaphyseal third metacarpal and metatarsal bone fractures: clinical outcome in 10 mature horses and 11 foals.

    Science.gov (United States)

    Bischofberger, A S; Fürst, A; Auer, J; Lischer, C

    2009-05-01

    Osteosynthesis of third metacarpal (McIII) and third metatarsal (MtIII) bone fractures in horses is a surgical challenge and complications surrounding the repair are common. Retrospective studies evaluating surgical repair, complications and outcome are necessary to increase knowledge and improve success of long bone fracture repair in the horse. To evaluate clinical findings, surgical repair, post operative complications and outcome of 10 mature horses and 11 foals with McIII or MtIII fractures that were treated with open reduction and internal fixation (ORIF). Medical records were reviewed and follow-up information obtained by means of radiographs and/or telephone questionnaire. Survival was achieved in 62% of the horses (3 mature/10 foals). On long-term evaluation (> 6 months) 11 horses (2 mature/9 foals) were fit for their intended activity, one mature horse had a chronic low grade lameness, and one foal was lost to follow-up because it was sold. The main fracture types were simple transverse (333%) or simple oblique (28.6%) and 71.4% of the fractures were open, 3 Type I (one mature/2 foals) and 12 type II (7 mature/5 foals). The preoperative assessment revealed inadequate emergency treatment in 10 horses (5 mature/5 foals; 47.6%). Survival rate of horses with open fractures was 12.5% (1/8) in mature and 85.7% (6/7) in foals. Post operative incisional infection (4 mature, 3 foals) was only managed successfully in 2 foals. Fracture instability related to inadequate fracture fixation technique occurred in 4 horses (all mature) and was always associated with unsuccessful outcome. Age, bodyweight and infection are strongly associated with outcome in treatment of complete McIII/MtIII fractures. Rigid fixation using plates and screws can be successful in treatment of closed or open, complete diaphyseal McIII/MtIII fractures in mature horses and foals. Instable fixation, infection and a bodyweight > 320 kg are major risk factors for unsuccessful outcome.

  7. Does morbid obesity negatively affect the hospital course of patients undergoing treatment of closed, lower-extremity diaphyseal long-bone fractures?

    Science.gov (United States)

    Baldwin, Keith D; Matuszewski, Paul E; Namdari, Surena; Esterhai, John L; Mehta, Samir

    2011-01-03

    Obesity is prevalent in the developed world and is associated with significant costs to the health care system. The effect of morbid obesity in patients operatively treated for long-bone fractures of the lower extremity is largely unknown. The National Trauma Data Bank was accessed to determine if morbidly obese patients (body mass index >40) with lower extremity fractures have longer length of hospital stay, higher cost, greater rehabilitation admission rates, and more complications than nonobese patients. We identified patients with operatively treated diaphyseal femur (6920) and tibia (5190) fractures. Polytrauma patients and patients younger than 16 years were excluded. Morbidly obese patients were identified by ICD-9 and database comorbidity designation (femur, 131 morbidly obese; tibia, 75 morbidly obese). Patients meeting these criteria who were not morbidly obese were used as controls. Sensitivity analyses were performed to analyze patients with isolated trauma to the tibia or femur. Morbidly obese patients were more likely to be admitted to a subacute facility. Length of stay trended higher in morbidly obese patients. There was no significant relationship between obesity and inpatient mortality or inpatient complications. These trends held true when considering patients with multiple injuries and patients who had isolated long-bone injuries. Our study showed that morbidly obese patients may have greater rehabilitation needs following long-bone fractures in the lower extremity. Our study showed no difference in mortality or complications, although further studies are needed to confirm these findings. Copyright 2011, SLACK Incorporated.

  8. Comparative characteristics of osteosynthesis techniques in patients with comminuted diaphyseal femoral fractures

    Directory of Open Access Journals (Sweden)

    A. P. Barabash

    2013-01-01

    Full Text Available The comparative analysis of the results of the surgical treatment of 130 patients with closed comminuted unilateral diaphyseal femoral fractures, including assessment of anatomic functional outcomes of treatment according to the technique of the standardized investigations in traumatology and orthopedy and determination of quality of life according to SF-36 method is carried out. Osteosynthesis with the help of external fixation devices was performed in 36 patients, intramedullary interlocking osteosynthesis - in 57 patients, compression plating - in 37 patients. Level of anatomic functional rehabilitation of the patients in the early postoperative period made up 69-79 %, 6 months later increased up to 74-92%, and after the expiration of 12 months the level of rehabilitation reached 85-99%. During the treatment quality of life concerning physical component was within the limits from 36,8 up to 55,5 %, and concerning mental component - 54,3-60,8 %. After the expiration of a year increase in the parameters of physical and mental components up to 55,7 - 59,8 % and 57,2-65,8 % is detected respectively. In the group where the transosseous osteosynthesis technique was applied we got 93,7-95 % of positive outcomes, with the average disability period of 212,3±18,1 days. In 47,2 % of cases the following complications are observed: knee contracture - 7; inflammation of the soft tissues located near the transosseous fixators - 5 (13,9%; shortening of the limb less than 5% of its length - 3; false joint formation - 1; fracture union with formation of varus deformity in the femoral bone - 1. When using intramedullary interlocking osteosynthesis we had positive results in 96,5 % of cases, with the average period of disability 176±17,8 days. In 10,5 % cases the following complications are observed: suture sinus - 1(1,75 %; femoral osteomyelitis - 1; break of the design - 1; false joint formation - 1; knee contracture - 1; shortening of the limb less than 5

  9. The mechanical benefit of medial support screws in locking plating of proximal humerus fractures.

    Directory of Open Access Journals (Sweden)

    Wen Zhang

    Full Text Available BACKGROUND: The purpose of this study was to evaluate the biomechanical advantages of medial support screws (MSSs in the locking proximal humeral plate for treating proximal humerus fractures. METHODS: Thirty synthetic left humeri were randomly divided into 3 subgroups to establish two-part surgical neck fracture models of proximal humerus. All fractures were fixed with a locking proximal humerus plate. Group A was fixed with medial cortical support and no MSSs; Group B was fixed with 3 MSSs but without medial cortical support; Group C was fixed with neither medial cortical support nor MSSs. Axial compression, torsional stiffness, shear stiffness, and failure tests were performed. RESULTS: Constructs with medial support from cortical bone showed statistically higher axial and shear stiffness than other subgroups examined (P<0.0001. When the proximal humerus was not supported by medial cortical bone, locking plating with medial support screws exhibited higher axial and torsional stiffness than locking plating without medial support screws (P ≤ 0.0207. Specimens with medial cortical bone failed primarily by fracture of the humeral shaft or humeral head. Specimens without medial cortical bone support failed primarily by significant plate bending at the fracture site followed by humeral head collapse or humeral head fracture. CONCLUSIONS: Anatomic reduction with medial cortical support was the stiffest construct after a simulated two-part fracture. Significant biomechanical benefits of MSSs in locking plating of proximal humerus fractures were identified. The reconstruction of the medial column support for proximal humerus fractures helps to enhance mechanical stability of the humeral head and prevent implant failure.

  10. A modified surgical technique for neglected fracture of lateral humeral condyle in children.

    Science.gov (United States)

    Sulaiman, Abdul Razak; Munajat, Ismail; Mohd, Emil Fazliq

    2011-11-01

    Operative treatment for neglected fracture of lateral humeral condyle (LHC) is difficult because of contracted muscle, fibrous tissue formation, and indistinct bony edges. Its success depends on the ability to preserve blood supply during the surgery. We retrospectively reviewed eight cases of neglected fracture of LHC in children treated with open reduction with selected multiple 'V' lengthening of common extensor muscle and internal fixation. The patients were between 3 and 8 years of age. The period of neglect was between 3 and 20 weeks. Four patients with displacement of more than 10 mm and neglect for 5 weeks or more required lengthening of common extensor muscle aponeurosis. The follow-up assessments were between 1 and 6.3 years with a mean of 4.4 years. All patients had union by 2 months. They gained improvement of flexion range of motion between 60° and 120° with a mean of 86.3°. Loss of final range of motion compared with the normal side was between 5° and 35° with a mean of 10°. No patient had limitation of activities or pain. Six cases had excellent and two cases had good Dillon functional score. All patients had lateral condyle prominent with different severities. There was one mild avascular necrosis and one fishtail deformity. Both of them had almost full range of motion. All patients had early physeal closure, except one, who had only 1 year follow-up. There was no case of progressive valgus deformity. Children with neglected fracture of LHC would benefit from anatomical reduction and internal fixation through a proper exposure and if indicated combined with multiple 'V' lengthening of common extensor muscle aponeurosis. This is a level IV study.

  11. Shoulder Arthroplasty for Humeral Head Avascular Necrosis Is Associated With Increased Postoperative Complications.

    Science.gov (United States)

    Burrus, M Tyrrell; Cancienne, Jourdan M; Boatright, Jeffrey D; Yang, Scott; Brockmeier, Stephen F; Werner, Brian C

    2018-02-01

    Humeral head avascular necrosis (AVN) of differing etiologies may lead to shoulder arthroplasty due to subchondral bone collapse and deformity of the articular surface. There have been no large studies evaluating the complications for these patients after they undergo total shoulder arthroplasty (TSA). The first objective of this study is to evaluate the complication rate after TSA in patients with humeral head AVN. The secondary objective is to compare the complication rates among the different etiologies of the AVN. Patients who underwent TSA were identified in the PearlDiver database using ICD-9 codes. Patients who underwent shoulder arthroplasty for humeral head AVN were identified using ICD-9 codes and were subclassified according to AVN etiology (posttraumatic, alcohol use, chronic steroid use, and idiopathic). Complications evaluated included postoperative infection within 6 months, dislocation within 1 year, revision shoulder arthroplasty up to 8 years postoperatively, shoulder stiffness within 1 year, and periprosthetic fracture within 1 year and systemic complications within 3 months. Postoperative complication rates were compared to controls. The study cohorts included 4129 TSA patients with AVN with 141,778 control TSA patients. Patients with posttraumatic AVN were significantly more likely to have a postoperative infection (OR 2.47, P  AVN was associated with a significantly increased risk for a postoperative infection (OR 1.72, P  = 0.004), revision surgery (OR 1.33, P  = 0.040), fracture (OR 2.76, P  = 0.002), and systemic complication (OR 1.59, P  AVN were not significantly associated with any of the postoperative evaluated complications. TSA in patients with humeral head AVN is associated with significantly increased rates of numerous postoperative complications compared to patients without a diagnosis of AVN, including infection, dislocation, revision arthroplasty, stiffness, periprosthetic fracture, and medical complications

  12. Complications during removal of stainless steel versus titanium nails used for intramedullary nailing of diaphyseal fractures of the tibia.

    Science.gov (United States)

    Seyhan, Mustafa; Guler, Olcay; Mahirogullari, Mahir; Donmez, Ferdi; Gereli, Arel; Mutlu, Serhat

    2018-02-01

    Intramedullary nailing is the treatment of choice for fractures of the tibial shaft, which might necessitate the nail removal due to complications in the long-term. Although considered as a low-risk procedure, intramedullary nail removal is also associated with certain complications. Here, we compared the most commonly used stainless steel and titanium nails with respect to the complications during removal and clinical outcome for intramedullary nailing of diaphyseal fractures of the tibia. Sixty-two patients (26 females, 36 males) were included in this retrospective study. Of the removed nails, 24 were of stainless steel and 38 of titanium. Preoperative and intraoperative parameters, such as implant discomfort, anterior knee pain, operating time and amount of bleeding, and postoperative outcomes were evaluated for each patient. Titanium nail group had more, but not statistically significant, intraoperative complications than stainless steel group during the removal of nails (p = .4498). Operating time and amount of intraoperative bleeding were significantly higher in titanium group than stainless steel group (p = .0306 and p titanium nails than those of stainless steel nails, whereas there was no difference in terms of postoperative SF-36 and KSS scores. In conclusion, although greater bone contact with titanium increases implant stability, nail removal is more difficult, resulting in more longer surgical operation and more intraoperative bleeding. Therefore, we do not recommend titanium nail removal in asymptomatic patients.

  13. The prevalence of the complications and their associated factors in humeral lengthening for achondroplasia: retrospective study of 54 cases.

    Science.gov (United States)

    Nakano-Matsuoka, Natsuko; Fukiage, Kenichi; Harada, Yuki; Kashiwagi, Naoya; Futami, Tohru

    2017-11-01

    The aim of this study is to evaluate the complications of humeral lengthening and their associated factors. Fifty-four achondroplastic patients were treated by bilateral humeral lengthening. Our original shoulder sling was sufficient to prevent shoulder dislocation. Pre-existing radial head dislocation was observed in 18 patients. Lengthening was accomplished in all cases without a decrease in the elbow function. Seven humeri fractured after the fixator removal. The risk factors for postoperative fracture were a waiting period of less than 5 days, a healing index less than 25, and the concave shape of the callus. There was no radial nerve palsy.

  14. Management of long bone fractures using SIGN nail: experience ...

    African Journals Online (AJOL)

    Background: Intramedullary nailing with interlocking nails has become the treatment of choice for closed diaphyseal fractures of femur and tibia. When possible locked nailing should be performed as a closed procedure. Fractures fixed by interlocking nailing have comparatively less complications in fracture healing.

  15. Complications during removal of stainless steel versus titanium nails used for intramedullary nailing of diaphyseal fractures of the tibia

    Directory of Open Access Journals (Sweden)

    Mustafa Seyhan

    2018-02-01

    Full Text Available Objectives: Intramedullary nailing is the treatment of choice for fractures of the tibial shaft, which might necessitate the nail removal due to complications in the long-term. Although considered as a low-risk procedure, intramedullary nail removal is also associated with certain complications. Here, we compared the most commonly used stainless steel and titanium nails with respect to the complications during removal and clinical outcome for intramedullary nailing of diaphyseal fractures of the tibia. Patients and methods: Sixty-two patients (26 females, 36 males were included in this retrospective study. Of the removed nails, 24 were of stainless steel and 38 of titanium. Preoperative and intraoperative parameters, such as implant discomfort, anterior knee pain, operating time and amount of bleeding, and postoperative outcomes were evaluated for each patient. Results: Titanium nail group had more, but not statistically significant, intraoperative complications than stainless steel group during the removal of nails (p = .4498. Operating time and amount of intraoperative bleeding were significantly higher in titanium group than stainless steel group (p = .0306 and p < .001, respectively. Preoperative SF-36 physical component and KSS scores were significantly lower in patients who had removal of titanium nails than those of stainless steel nails, whereas there was no difference in terms of postoperative SF-36 and KSS scores. Conclusion: In conclusion, although greater bone contact with titanium increases implant stability, nail removal is more difficult, resulting in more longer surgical operation and more intraoperative bleeding. Therefore, we do not recommend titanium nail removal in asymptomatic patients. Keywords: Fractures of tibial shaft, Removal of intramedullary nailing, Stainless steel nail, Titanium nail

  16. [Operative treatment of proximal humeral four-part fractures in elderly patients: comparison of two angular-stable implant systems].

    Science.gov (United States)

    Kuhlmann, T; Hofmann, T; Seibert, O; Gundlach, G; Schmidt-Horlohé, K; Hoffmann, R

    2012-04-01

    Although being one of the most common fractures in elderly patients, there is still no standardised treatment protocol for four-part fractures of the proximal humerus. However, a wide variety of angular-stable implants is available. The present retrospective study compares the clinical and radiological outcome following operative treatment of four-part fractures of the proximal humerus with the Philos system (Philos, proximal humeral internal locking system, Synthes GmbH, Umkirch Germany) and the angular-stable Königsee plate system (Königsee Implantate GmbH, Allendorf, Germany) in patients older than 65 years. From July 2005 until December 2007 we identified 77 patients with a four-part fracture of the proximal humerus who were treated operatively with one of the two implant systems. Of the patients, 17 could not be located so that in total 60 patients (78 %) participated in this study. The mean age of the 30 patients (10 m, 20 f) in the Philos group was 69 years (65-92), whereas the mean age of the 30 patients (11 m, 19 f) in the Königsee group was 71 years (65-93). A comprehensive assessment was performed after a median of 17 months (12-24), including physical examination, radiographic examination and completion of the disabilities of the arm, shoulder and hand score (DASH) and the Constant score (CS) as patient-oriented, limb-specific questionnaires. Neither in the Philos nor in the Königsee group could excellent results be achieved. Using the CS 13 patients (43 %) of the Philos group achieved a good and 15 (50 %) a satisfactory result. Bad results were found in 2 patients (7 %). The mean CS was 61.53 points. In the Königsee group mean CS was 61.76 points. In detail, 14 patients (47 %) treated with the Königsee implant were rated as good and 15 (50 %) as satisfactory. Only 1 patient (3 %) was rated as poor. No significant statistical differences were found between the groups. Mean DASH score in the Philos group was 56.30 points and 55.37 points in the K

  17. Medullary bone and humeral breaking strength in laying hens

    International Nuclear Information System (INIS)

    Fleming, R.H.; McCormack, H.A.; McTeir, L.; Whitehead, C.C.

    1998-01-01

    To test the hypothesis that large amounts of medullary bone in the humeral diaphysis may increase breaking strength, various parameters of bone quality and quantity were examined in two large flocks of hens near end of lay. We conclude that the amount of medullary bone in the humerus of hens during the laying period influences bone strength. This medullary bone may not have any intrinsic strength, but may act by contributing to the fracture resistance of the surrounding cortical bone. Using a quantitative, low dose, radiographic technique, we can predict, from early in the laying period, those birds which will develop large amounts of medullary bone in their humeri by the end of the laying period. The formation of medullary bone in the humeral diaphysis is not at the expense of the surrounding radiographed cortical bone

  18. Dispositivo de tração do membro superior para osteossínteses intramedulares bloqueadas anterógradas de fraturas diafisárias de úmero Upper limb traction device for anterograde intramedullary locked nail of humeral shaft fractures

    Directory of Open Access Journals (Sweden)

    Mário Chaves Corrêa

    2010-06-01

    Full Text Available As fraturas diafisárias de fêmur e tíbia no adulto são, na sua maioria, tratadas cirurgicamente, geralmente através de osteossínteses intramedulares bloqueadas. Algumas fraturas diafisárias cominutivas e/ou muito desviadas podem representar um verdadeiro desafio técnico. As mesas de fraturas (ou ortopédicas, que permitem a estabilização instrumental vertical, horizontal e rotacional do membro, facilitam enormemente as manobras de redução e de colocação do implante e são amplamente utilizadas pelos cirurgiões ortopédicos. As fraturas diafisárias de úmero são, na sua maioria, tratadas não cirurgicamente. Entretanto, algumas requerem o tratamento cirúrgico, cujas indicações estão bem definidas na literatura. Podem ser fixadas através de placas ou de hastes intramedulares por via anterógrada ou retrógrada. No úmero, as manobras de redução da fratura e estabilização do membro para a implantação da haste intramedular são realizadas manualmente, geralmente por dois auxiliares e, por serem sujeitas à fadiga muscular, podem ser menos eficientes. O objetivo deste trabalho é apresentar um dispositivo externo de tração do membro superior para utilização em osteossínteses intramedulares bloqueadas anterógradas de fraturas diafisárias de úmero que permite a estabilização vertical, horizontal e rotacional do membro superior, de maneira similar àquela utilizada para os membros inferiores. O dispositivo é portátil, de construção simples, e pode ser instalado em qualquer mesa cirúrgica equipada com trilhos laterais. Foi utilizado no tratamento cirúrgico de 29 fraturas diafisárias de úmero com haste intramedular bloqueada anterógrada. Nossa experiência foi extremamente positiva. Não tivemos nenhuma complicação relacionada à sua utilização, que acreditamos ter facilitado, de maneira notável, os procedimentos cirúrgicos.Diaphyseal fractures of the femur and tibia in adults are mostly treated

  19. ANALYSIS ON THE VARIATION OF MEDIAL ROTATION VALUES ACCORDING TO THE POSITION OF THE HUMERAL DIAPHYSIS.

    Science.gov (United States)

    Miyazaki, Alberto Naoki; Fregoneze, Marcelo; Santos, Pedro Doneux; da Silva, Luciana Andrade; do Val Sella, Guilherme; Cohen, Carina; Busin Giora, Taís Stedile; Checchia, Sergio Luiz; Raia, Fabio; Pekelman, Hélio; Cymrot, Raquel

    2012-01-01

    To analyze the validity of measurements of medial rotation (MR) of the shoulder, using vertebral levels, according to the variation in the position of the humeral diaphysis, and to test the bi-goniometer as a new measuring instrument. 140 shoulders (70 patients) were prospectively evaluated in cases presenting unilateral shoulder MR limitation. The vertebral level was evaluated by means of a visual scale and was correlated with the angle obtained according to the position of the humeral diaphysis, using the bi-goniometer developed with the Department of Mechanical Engineering of Mackenzie University. The maximum vertebral level reached through MR on the unaffected side ranged from T3 to T12, and on the affected side, from T6 to the trochanter. Repositioning of the affected limb in MR according to the angular values on the normal side showed that 57.13% of the patients reached lower levels, between the sacrum, gluteus and trochanter. From analysis on the maximum vertebral level attained and the variation between the affected angle x (frontal plane: abduction and MR of the shoulder) and the unaffected angle x in MR, we observed that the greater the angle of the diaphyseal axis was, the lower the variation in the vertebral level attained was. From evaluating the linear correlation between the variables of difference in maximum vertebral level reached and variation in the affected angle y (extension and abduction of the shoulder) and the unaffected angle y in MR, we observed that there was no well-established linear relationship between these variables. Measurement of MR using vertebral levels does not correspond to the real values, since it varies according to the positioning of the humeral diaphysis.

  20. Evaluation of Outcomes of Open Reduction and Internal Fixation Surgery in Patients with Type C Distal Humeral Fractures

    Directory of Open Access Journals (Sweden)

    Mohammadhadi Nouraei

    2018-01-01

    Full Text Available Background: In this study, functional state of patients with Type C distal humerus fractures undergone surgical plating was evaluated 6 and 12 months after the surgery in order to record postsurgical factors such as pain level and job/performance satisfaction. Materials and Methods: In this cross-sectional study, 46 patients with humerus fractures were recruited and their ability to do daily tasks, presence of degenerative changes, stability of elbow joint, and range of motion was evaluated. For assessment of response to surgery, Mayo score was used. Results: Among 46 patients, 45 (97.8% of them had joint stability. Evaluation of postsurgical complications showed that six subjects (13% had no complications, but superficial infection was observed in 12 (26.1% subjects. Neuromuscular disorders in ulnar nerve were present in 11 subjects (23.9%, recurrent articular bursitis of elbow joint in 6 subjects (13%, stiffness of elbow joint in 29 subjects (63%, nonunion of fracture in 3 subjects (6.5%, and myositis ossification in 4 (8.7% subjects. Furthermore, 18 (39.1% patients presented with more than one (2–4 complications. Conclusion: Open reduction and internal fixation surgery with dual plating is the method of choice for treatment of Type C distal humeral fractures. Evaluation of long-term outcomes of this surgery could be done via several different questionnaires as many studies suggest. This study demonstrated that the outcomes of this surgery in Isfahan, Iran, have been noticeably inferior compared to results of the studies in other parts of the world.

  1. Osteochondral lesions of the humeral trochlea in the young athlete

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, Kelley W. [Pediatric Radiology of America, Roanoke, VA (United States); Children' s Healthcare of Atlanta at Scottish Rite, Atlanta, GA (United States); Children' s Diagnostic Imaging of Atlanta, P.C., Marietta, GA (United States); Marshall, David L.; Busch, Michael T. [Children' s Orthopaedics of Atlanta, P.C., Atlanta, GA (United States); Children' s Healthcare of Atlanta at Scottish Rite, Atlanta, GA (United States); Williams, Joseph P. [Children' s Healthcare of Atlanta at Scottish Rite, Atlanta, GA (United States); Children' s Diagnostic Imaging of Atlanta, P.C., Marietta, GA (United States)

    2009-05-15

    The purpose of this study was to characterize the variety of osteochondral abnormalities of the humeral trochlea in the pediatric athlete. Patients with trochlear abnormalities were identified through keyword search of radiology dictations from 1999 to 2007. The patient's medical record, imaging studies, and surgical reports were reviewed. The osteochondral lesions were categorized based on the imaging appearance. Surgical results were reviewed in conjunction with the imaging findings. Eighteen patients were identified. Trochlear lesions were stratified into two imaging groups: Osteochondral injury/osteochondritis dissecans (OCD) vs. avascular necrosis (AVN). The osteochondral injury group was stratified into medial and lateral trochlear abnormalities. The medial lesions (n=3) were small (<6 mm) and were located on the posterior articular surface of the medial trochlea. The lateral lesions (n=10) were larger (10-14 mm), circumscribed, and were located on the posterior inferior aspect of the lateral trochlea. Trochlear AVN (n=5) affected development of the lateral trochlea (type A) or both the medial and lateral aspects of the trochlea (type B). AVN occurred exclusively in athletes with history of remote distal humeral fracture. Seven of the 18 patients underwent elbow arthroscopy. Surgical findings and treatment regimens are summarized. Trochlear lesions should be considered in throwing athletes presenting with medial elbow pain and flexion contracture/extension block. Medial trochlear osteochondral injuries may result from posteromedial olecranon abutment. Lateral OCD lesions occur in a characteristic vascular watershed zone resulting from the unique blood supply of the trochlea. Trochlear AVN may be unmasked years following treated distal humeral fracture when the athletic demands upon the adolescent elbow increase, revealing the altered growth and biomechanics. (orig.)

  2. Osteochondral lesions of the humeral trochlea in the young athlete

    International Nuclear Information System (INIS)

    Marshall, Kelley W.; Marshall, David L.; Busch, Michael T.; Williams, Joseph P.

    2009-01-01

    The purpose of this study was to characterize the variety of osteochondral abnormalities of the humeral trochlea in the pediatric athlete. Patients with trochlear abnormalities were identified through keyword search of radiology dictations from 1999 to 2007. The patient's medical record, imaging studies, and surgical reports were reviewed. The osteochondral lesions were categorized based on the imaging appearance. Surgical results were reviewed in conjunction with the imaging findings. Eighteen patients were identified. Trochlear lesions were stratified into two imaging groups: Osteochondral injury/osteochondritis dissecans (OCD) vs. avascular necrosis (AVN). The osteochondral injury group was stratified into medial and lateral trochlear abnormalities. The medial lesions (n=3) were small (<6 mm) and were located on the posterior articular surface of the medial trochlea. The lateral lesions (n=10) were larger (10-14 mm), circumscribed, and were located on the posterior inferior aspect of the lateral trochlea. Trochlear AVN (n=5) affected development of the lateral trochlea (type A) or both the medial and lateral aspects of the trochlea (type B). AVN occurred exclusively in athletes with history of remote distal humeral fracture. Seven of the 18 patients underwent elbow arthroscopy. Surgical findings and treatment regimens are summarized. Trochlear lesions should be considered in throwing athletes presenting with medial elbow pain and flexion contracture/extension block. Medial trochlear osteochondral injuries may result from posteromedial olecranon abutment. Lateral OCD lesions occur in a characteristic vascular watershed zone resulting from the unique blood supply of the trochlea. Trochlear AVN may be unmasked years following treated distal humeral fracture when the athletic demands upon the adolescent elbow increase, revealing the altered growth and biomechanics. (orig.)

  3. Metaphyseal and diaphyseal chondroblastomas

    Energy Technology Data Exchange (ETDEWEB)

    Maheshwari, Aditya V. [State University of New York Downstate Medical Center, Department of Orthopaedics and Rehabilitation, Brooklyn, NY (United States); Washington Hospital Center, Department of Orthopedic Oncology, Washington, DC (United States); Jelinek, James S.; Song, Albert J. [Washington Hospital Center, Department of Radiology, Washington, DC (United States); Nelson, Kenneth J.; Henshaw, Robert M. [Washington Hospital Center, Department of Orthopedic Oncology, Washington, DC (United States); Murphey, Mark D. [The American Institute for Radiologic Pathology, Silver Spring, MD (United States)

    2011-12-15

    Epiphyseal/apophyseal locations are important diagnostic radiological features of chondroblastomas (CB). Although the tumor may secondarily involve the metaphysis, reports of primary metaphyseal or diaphyseal CB without any epiphyseal or apophyseal involvement are exceptionally rare and frequently present as a diagnostic dilemma. The purpose of this study was to present seven cases of pure metaphyseal and/or diaphyseal CB along with a review of pertinent literature. A retrospective review of databases at two major referral centers revealed 390 cases of CB between 1960 and 2009. Out of these, seven histologically proven CB cases (1.8%) were found to be radiologically located in metaphysis and/or diaphysis, without involving the epiphysis and/or apophysis, and formed the study cohort. There were four males and three females (age range 2-25 years). Locations included proximal femur (n = 1), distal femur (2), proximal humerus (2), clavicle (1), and proximal radius (1). All lesions showed marginal sclerosis. A periosteal reaction was seen in five cases (71%), cortical expansion in four cases (57%), and chondroid matrix in four cases (57%). A CT (two cases) demonstrated a matrix in both cases. An MR (one case) showed extensive perilesional edema. Bone scan (one case) showed intense uptake. Pure metaphyseal and/or diaphyseal CB are exceedingly rare. A presumptive diagnosis may be considered in the appropriate age group in the presence of chondroid matrix, perilesional edema, periosteal reaction, and marginal sclerosis. Regardless of all the diagnostic possibilities, biopsy may still be required. However, knowledge of this entity will help make the final diagnosis and guide the correct treatment. (orig.)

  4. Epidemiologie et Aspects Anatomo-Pathologique des Fractures du ...

    African Journals Online (AJOL)

    Ils sont suivis des fractures de la tête fémorale (9,30%), les fractures des massifs trochantériens (9,11%). Les fractures de la diaphyse fémorale étaient de 50%, avec une prédilection au tiers moyen. Les fractures de l'extrémité inférieure ont représenté (9,10%) avec une prédominance des fractures supra condyliennes.

  5. Delay in weight bearing in surgically treated tibial shaft fractures is associated with impaired healing: a cohort analysis of 166 tibial fractures.

    Science.gov (United States)

    Houben, I B; Raaben, M; Van Basten Batenburg, M; Blokhuis, T J

    2018-04-09

    The relation between timing of weight bearing after a fracture and the healing outcome is yet to be established, thereby limiting the implementation of a possibly beneficial effect for our patients. The current study was undertaken to determine the effect of timing of weight bearing after a surgically treated tibial shaft fracture. Surgically treated diaphyseal tibial fractures were retrospectively studied between 2007 and 2015. The timing of initial weight bearing (IWB) was analysed as a predictor for impaired healing in a multivariate regression. Totally, 166 diaphyseal tibial fractures were included, 86 cases with impaired healing and 80 with normal healing. The mean age was 38.7 years (range 16-89). The mean time until IWB was significantly shorter in the normal fracture healing group (2.6 vs 7.4 weeks, p bearing is independently associated with impaired fracture healing in surgically treated tibial shaft fractures. Unlike other factors such as fracture type or soft tissue condition, early resumption of weight bearing can be influenced by the treating physician and this factor therefore has a direct clinical relevance. This study indicates that early resumption of weight bearing should be the treatment goal in fracture fixation. 3b.

  6. Changing incidence and residual lifetime risk of common osteoporosis-related fractures

    DEFF Research Database (Denmark)

    Lauritzen, J B; Schwarz, Peter; Lund, B

    1993-01-01

    1735 fractures of the distal radius, 747 fractures of the proximal humerus, 878 cervical and 635 trochanteric hip fractures were included. In men 273 cervical and 232 trochanteric hip fractures were included. The fractures were registered during the period 1976 to 1984 and changes in age.......05) during the observation period, while no significant decrease was found in the incidence of trochanteric fractures. No significant changes in incidence were observed in women with radial or humeral fractures, or in men with hip fractures. A women 60 years old with a life expectancy of 81 years had......Changes in incidence and lifetime risk of fractures are of major importance in the epidemiology of osteoporosis. We focused on hip fractures in women and men and on radial and humeral fractures in women. The study subjects comprised 4500 women and men 20 years old or more with fractures. In women...

  7. Attritional rupture of extensor pollicis longus: a rare complication following elastic stable intramedullary nailing of a paediatric radial fracture.

    LENUS (Irish Health Repository)

    Sproule, James A

    2011-01-01

    Elastic stable intramedullary nail fixation has become established as an acceptable method of treatment for diaphyseal fractures of both forearm bones in the paediatric population. It is considered safe, minimally invasive and does not compromise physeal growth. We report a case of delayed rupture of extensor pollicis longus due to attrition over the sharp edges of a protruding nail end after elastic stable intramedullary nailing of a paediatric radial diaphyseal fracture.

  8. Long-term outcome of segmental reconstruction of the humeral head for the treatment of locked posterior dislocation of the shoulder.

    Science.gov (United States)

    Gerber, Christian; Catanzaro, Sabrina; Jundt-Ecker, Michele; Farshad, Mazda

    2014-11-01

    Locked posterior glenohumeral dislocations with impaction fractures involving less than 30% to 35% of the humeral head are most frequently treated with lesser tuberosity transfer into the defect, whereas those involving more than 35% to 40% are treated with humeral head arthroplasty. As an alternative, reconstruction of the defect with segmental femoral or humeral head allograft has been proposed, but the long-term outcome of this joint-preserving procedure is unknown. Twenty-two shoulders in 21 patients with a locked posterior shoulder dislocation and an impaction of at least 30% (mean, 43%) of the humeral head were treated with segmental reconstruction of the humeral head defect. They were reviewed clinically and radiographically at a minimum follow-up of 5 years. Of the 22 shoulders, 19 could be followed up at 128 months (range, 60-294 months) postoperatively. Only 2 of the 19 patients needed a prosthesis more than 180 months after the index operation. Of the other 17, 4 had radiographically advanced osteoarthritis (OA), 4 had mild OA, and 9 had no or minimal OA. Eighteen shoulders were rated as subjectively excellent, none were rated as good, and one was rated as fair. The final Constant-Murley score averaged 77 points (range, 52-98 points), the Subjective Shoulder Value averaged 88% (range, 75%-100%), and only 2 patients had mild to moderate pain. Mean active anterior elevation was 145°, and mean external rotation with the arm at the side was 42°. Segmental reconstruction of humeral head defects for large anteromedial impaction fractures caused by locked posterior dislocations durably restores stability and freedom from pain with an excellent subjective long-term outcome. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  9. Management of tibial fractures using a circular external fixator in two calves.

    Science.gov (United States)

    Aithal, Hari Prasad; Kinjavdekar, Prakash; Amarpal; Pawde, Abhijit Motiram; Singh, Gaj Raj; Setia, Harish Chandra

    2010-07-01

    To report the repair of tibial diaphyseal fractures in 2 calves using a circular external skeletal fixator (CEF). Clinical report. Crossbred calves (n=2; age: 6 months; weight: 55 and 60 kg). Mid-diaphyseal tibial fractures were repaired by the use of a 4-ring CEF (made of aluminum rings with 2 mm K-wires) alone in 1 calf and in combination with hemicerclage wiring in 1 calf. Both calves had good weight bearing with moderate lameness postoperatively. Fracture healing occurred by day 60 in 1 calf and by day 30 in calf 2. The CEF was well maintained and tolerated by both calves through fracture healing. Joint mobility and limb usage improved gradually after CEF removal. CEF provided a stable fixation of tibial fractures and healing within 60 days and functional recovery within 90 days. CEF can be safely and successfully used for the management of selected tibial fractures in calves.

  10. Comparison of our self-designed rotary self-locking intramedullary nail and interlocking intramedullary nail in the treatment of long bone fractures.

    Science.gov (United States)

    Liu, Bailian; Xiong, Ying; Deng, Hong; Gu, Shao; Jia, Fu; Li, Qunhui; Wang, Daxing; Gan, Xuewen; Liu, Wei

    2014-07-21

    The purpose of this study is to compare the clinical effects of our self-designed rotary self-locking intramedullary nail (RSIN) and interlocking intramedullary nail (IIN) for long bone fractures. A retrospective study was performed in 1,704 patients who suffered bone fractures and underwent RSIN or IIN operation in our hospital between March 1999 and March 2013, including 494 with femoral fractures, 572 with humeral fractures, and 638 with tibial fractures. Among them, 634 patients were followed up for more than 1 year. The operative time, intraoperative blood loss, postoperative complications, healing rate, and the excellent and good rate of functional recovery were compared between two groups. Compared with IIN group, RSIN group exhibited significantly shorter operative time and less intraoperative blood loss no matter for humeral, femoral, or tibial fractures (all p fractures (both p fracture. In IIN group, nail breakage or loosening occurred in 7 patients with femoral fractures and 16 patients with tibial fractures, radial nerve injury was observed in 8 patients with humeral fractures, and incision infection was present in 2 patients with humeral fractures and 1 patient with femoral fracture. The complication rate of IIN group was significantly higher than that of RSIN group (p knee, and ankle joint functional recovery between RSIN group and IIN group. RSIN may be a reliable and practical alternative method for the treatment of long bone fractures.

  11. Biomechanical comparison of 3.0 mm headless compression screw and 3.5 mm cortical bone screw in a canine humeral condylar fracture model.

    Science.gov (United States)

    Gonsalves, Mishka N; Jankovits, Daniel A; Huber, Michael L; Strom, Adam M; Garcia, Tanya C; Stover, Susan M

    2016-09-20

    To compare the biomechanical properties of simulated humeral condylar fractures reduced with one of two screw fixation methods: 3.0 mm headless compression screw (HCS) or 3.5 mm cortical bone screw (CBS) placed in lag fashion. Bilateral humeri were collected from nine canine cadavers. Standardized osteotomies were stabilized with 3.0 mm HCS in one limb and 3.5 mm CBS in the contralateral limb. Condylar fragments were loaded to walk, trot, and failure loads while measuring construct properties and condylar fragment motion. The 3.5 mm CBS-stabilized constructs were 36% stiffer than 3.0 mm HCS-stabilized constructs, but differences were not apparent in quality of fracture reduction nor in yield loads, which exceeded expected physiological loads during rehabilitation. Small residual fragment displacements were not different between CBS and HCS screws. Small fragment rotation was not significantly different between screws, but was weakly correlated with moment arm length (R² = 0.25). A CBS screw placed in lag fashion provides stiffer fixation than an HCS screw, although both screws provide similar anatomical reduction and yield strength to condylar fracture fixation in adult canine humeri.

  12. Percutaneous Kirschner wire (K-wire) fixation for humerus shaft fractures in children: A treatment concept.

    Science.gov (United States)

    Sahu, Ramji Lal

    2013-09-01

    Fractures of the humeral shaft are uncommon, representing less than 10 percent of all fractures in children. Humeral shaft fractures in children can be treated by immobilisation alone. A small number of fractures are unable to be reduced adequately or maintained in adequate alignment, and these should be treated surgically. In the present study, Kirschner wires (K-wire) were used to achieve a closed intramedullary fixation of humeral shaft fractures. The objective of this study was to evaluate the efficacy of intramedullary K-wires for the treatment of humeral shaft fracture in children. This prospective study was conducted in the Department of Orthopaedic surgery in M. M. Medical College from June 2005 to June 2010. Sixty-eight children with a mean age of 7.7 years (range, 2-14 years) were recruited from Emergency and out patient department having closed fracture of humerus shaft. All patients were operated under general anaesthesia. All patients were followed for 12 months. Out of 68 patients, 64 patients underwent union in 42-70 days with a mean of 56 days. Complications found in four patients who had insignificant delayed union which were united next 3 weeks. Intramedullary K-wires were removed after an average of 5 months without any complications. The results were excellent in 94.11% and good in 5% children. This technique is simple, quick to perform, safe and reliable and avoids prolonged hospitalization with good results and is economical.

  13. Unusual longitudinal stress fractures of the femoral diaphysis: report of five cases

    International Nuclear Information System (INIS)

    Williams, M.; Timsit, M.A.; Karneff, A.; Pertuiset, E.

    1999-01-01

    We present five cases of a distinctive type of longitudinal stress fracture of the upper femoral shaft in which the fracture line is parallel to the outer surface of the bone, in contrast to the perpendicular orientation to the cortical surface in previously reported cases of diaphyseal stress fractures. In two cases the fracture recurred after 15 and 18 months, respectively. (orig.)

  14. SUPRACONDYLAR FRACTURE OF THE HUMERUS IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Nikola Bojović

    2012-09-01

    Full Text Available Humeral supracondylar fractures are the second most common fractures seen in children and young teenagers (16.6%. They represent 60-70% of all the elbow fractures. The maximum incidence is found between the fifth and seventh year of age, slightly more often in boys and on non-dominant hand. We performed a retrospective study in our clinic which included 105 patients admitted to our facility during the period from January, 2008 to April, 2012. The included patients had humeral supracondylar fracture either type 2 or type 3 (Gartland classification. At the moment of admission the median age was 7.26 years. All the patients were treated during the first 12 hours, with no more than two attempts of closed reposition. Sixteen patients with type 2 fracture were treated by analgosedation, closed reduction followed by cast immobilization. All other patients were treated after induction of general anesthesia. Sixteen patients were treated by percutaneous fixation of the fragments after closed reduction and 73 were treated with open reduction and pinning with different number and positions of „К“ wires. None of the patients had deep tissue infection; four patients had pin site infection. Three patients had cubitus varus deformity, two patients had elbow contracture, five patients had temporary limitation in extension, and one patient had iatrogenic lesion of the ulnar nerve. This makes 14.2% complication rate in our series. All the fractures healed in the expected period (3–4 weeks. Bauman’s angle, carrying angle and functional factor were measured postoperatively. Closed reposition with pinning, using radiographic control, for the dislocated supracondylar humeral fractures is the safest, as well as the least time consuming and cost-effective method. We also suggest treating these fractures within 12 hours and conversion of closed into open reposition in case of lacking crepitations (possibility of interposition of soft tissues between fragments.

  15. Ball-thrower's fracture of the humerus

    International Nuclear Information System (INIS)

    Callaghan, Eric B.; Bennett, D. Lee; El-Khoury, Georges Y.; Ohashi, Kenjirou

    2004-01-01

    A relatively rare case of ball-thrower's fracture of the humerus is presented. Severe muscular action is an uncommon cause of humeral fractures but has been well documented in the orthopedic literature. To our knowledge, this fracture has not been described in the radiology literature, and awareness of this entity could preclude further unnecessary workup. The mechanism of injury and its typical radiographic appearance is described. (orig.)

  16. Intrathoracic fracture-dislocation of the humerus - case report and literature review

    Directory of Open Access Journals (Sweden)

    Wilson Carlos Sola Junior

    Full Text Available ABSTRACT Shoulder fracture-dislocations are uncommon. Those associated with intrathoracic dislocation are very rare conditions, resulting from high-energy trauma; usually, the affected limb is in an abduction position. In Brazil, there is only one report of a teenager with displacement of the epiphysis into the chest cavity; the present is the first adult patient report of intrathoracic dislocation of the humerus. The authors present the case of a patient female, aged 56 years, who was hit by motorcycle and thrown approximately 5 meters away. She was rescued on site with thoracic, pelvic, and right upper limb trauma. Her chest was drained due to pneumothorax and multiple fractures of ribs; she was diagnosed with fracture-dislocation in four parts, with intrathoracic dislocation of the humeral head. Displaced forearm bones fracture was also diagnosed; the olecranon, scaphoid, and ischiopubic fractures were not displaced. The patient underwent a joint procedure with a cardiothoracic surgery team to remove the humeral head through thoracotomy and chest drainage; subsequently, a partial arthroplasty of the humerus was performed, with graft from the humeral head and fixation of forearm fractures. Conservative treatment was chosen for the other fractures. After three months, all fractures were healed with gradual functional improvement. The patient remained in physiotherapy and orthopedic monitoring, having been discharged from the thoracic surgery; in a severe depressive episode, the patient committed suicide after 11 months of the trauma.

  17. Plate Fixation With Autogenous Calcaneal Dowel Grafting Proximal Fourth and Fifth Metatarsal Fractures: Technique and Case Series.

    Science.gov (United States)

    Seidenstricker, Chad L; Blahous, Edward G; Bouché, Richard T; Saxena, Amol

    Metaphyseal and proximal diaphyseal fractures of the lateral column metatarsals can have problems with healing. In particular, those involving the fifth metatarsal have been associated with a high nonunion rate with nonoperative treatment. Although intramedullary screw fixation results in a high union rate, delayed healing and complications can occur. We describe an innovative technique to treat both acute and chronic injuries involving the metatarsal base from the metaphysis to the proximal diaphyseal bone of the fourth and fifth metatarsals. The surgical technique involves evacuation of sclerotic bone at the fracture site, packing the fracture site with compact cancellous bone, and plate fixation. In our preliminary results, 4 patients displayed 100% radiographic union at a mean of 4.75 (range 4 to 6) weeks with no incidence of refracture, at a mean follow-up point of 3.5 (range 1 to 5) years. The early results with our small series suggest that this technique is a useful treatment choice for metaphyseal and proximal diaphyseal fractures of the fourth and fifth metatarsals. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Intrathoracic deplacement of the fractured humerus head mimicking lung mass

    International Nuclear Information System (INIS)

    Incedayi, M.; Sivrioglu, A.; Candas, F.

    2012-01-01

    Full text: 79-year-old woman was admitted to emergency department because she had a trauma to her right shoulder. In chest X ray film and CT orientated to her right shoulder; fragmented proximal humeral fracture and right 3. rib fracture, hemopneumothorax, subcutaneous emphysema related to rib fracture were detected. In CT exam which is performed at one month after the trauma was viewed that a well defined, 3.5 cm in diameter, spheric, sharp in medial contour, osseous structure in right hemithorax. The intrathoracic osseous lesion was the fragmented and dislocated humeral head. if we see a bone structure in the lung while we reporting a chest-X-ray in a trauma patient, we have to retain that this structure might be the fractured and dislocated humerus head

  19. Daily number of fractures is associated with road temperature in an urban area

    DEFF Research Database (Denmark)

    Jantzen, Christopher; Jørgensen, Henrik L; Thomsen, Morten

    2014-01-01

    winters. MATERIAL AND METHODS: Retrospective data collection was conducted on all patients treated at Bispebjerg Hospital, Denmark, for a humeral, ankle, distal radius or hip fracture during the periods October to April 2009/2010 and 2010/2011. Patients were grouped according to age into the following......,938 fractures) were treated during the study periods. The daily number of distal radius, humeral and ankle fractures increased significantly with decreasing road surface temperature and the presence of IA. For hip fractures no significant association was found. Decreasing temperature was associated......INTRODUCTION: Different factors related to winter are known to influence the fracture incidence, but little is known about the effect of road surface temperature. This study examines the association between road surface temperature and the daily number of fractures in an urban area during two...

  20. Ultra-som pulsado de baixa intensidade em fraturas diafisárias: aplicação clínica em cães Low-intensity pulsed ultrasound in diaphyseal fractures: clinical application in dogs

    Directory of Open Access Journals (Sweden)

    Valéria Lima de Sousa

    2008-08-01

    Full Text Available Os efeitos da estimulação ultra-sônica sobre a consolidação óssea têm sido demonstrados por trabalhos experimentais e clínicos. Este estudo teve por objetivo investigar a aplicação clínica do ultra-som pulsado de baixa intensidade como tratamento adjuvante de fraturas diafisárias em cães. Foram utilizados 16 cães de raças variadas, com faixa etária entre sete meses e seis anos, peso corpóreo entre 2,5 e 43kg, portadores de fraturas diafisárias fechadas recentes localizadas no rádio e ulna, fêmur ou tíbia e fíbula, estabilizadas por procedimentos de osteossíntese (fixação esquelética externa, pinos intramedulares ou a associação desses métodos. Os cães foram divididos em dois grupos: fraturas estabilizadas tratadas por ultra-som de baixa intensidade (grupo tratado, n=8; fraturas estabilizadas, não tratadas por estimulação ultra-sônica, (grupo controle, n=8. Os animais foram avaliados por exames clínicos e radiográficos nos períodos pré-operatório, pós-operatório imediato e a cada 30 dias posteriores aos procedimentos cirúrgicos. Realizou-se tratamento com ultra-som pulsado (sinal senoidal com freqüência de 1,5MHz, largura de pulso de 200µs e freqüência de repetição de 1kHz de baixa intensidade (30mW cm-2, aplicado de modo estacionário no foco de fratura. A terapia ultra-sônica foi realizada 20 minutos por dia, durante 21 dias consecutivos, a partir do período compreendido entre o 1° e o 9° dia pós-operatório. O teste t de Student, empregado na análise estatística, mostrou diferença significante (PThe effects of ultrasound stimulation on bone healing have been demonstrated in experimental and clinical studies. The purpose of this study was to investigate the clinical application of low-intensity pulsed ultrasound as an adjuvant for the treatment of diaphyseal fractures in dogs. Sixteen dogs of different breeds, ages ranging from seven months to six years, weighing from 2.5 to 43kg, were

  1. Midshaft clavicle fractures with associated ipsilateral acromioclavicular joint dislocations: Incidence and risk factors.

    Science.gov (United States)

    Ottomeyer, Christina; Taylor, Benjamin C; Isaacson, Mark; Martinez, Lara; Ebaugh, Pierce; French, Bruce G

    2017-02-01

    Simultaneous ipsilateral clavicle and acromioclavicular (AC) joint injury have been infrequently reported in the literature at this time. The purpose of this study was to assess incidence as well as assess risk factors for this dual injury pattern. We performed a retrospective review of a prospectively collected database (Level III evidence), evaluating 383 adult patients without previous shoulder girdle injury or trauma with a minimum 1-year follow-up who sustained a displaced diaphyseal clavicle fracture. All patients in the study underwent either nonoperative management or surgical reduction and stabilization of a diaphyseal clavicle fracture with a plate and screw construct. Study subjects were followed with serial radiographs. Clavicle and shoulder radiographs, as well as chest radiographs and contralateral films in questionable cases, were used to assess for acromioclavicular joint injury in both operative and nonoperative groups. Additional data was collected on concurrent injuries, patient demographics, fracture characteristics, fixation techniques, surgical/post-operative data, and operative or nonoperative treatment. We found that 13/183 (7.1%) of patients undergoing fixation of a diaphyseal clavicle fracture had an ipsilateral AC joint injury, while 13/200 (6.5%) of patients undergoing conservative management had an ipsilateral AC joint injury. Critical analysis of the data revealed that presence of ipsilateral scapular body fractures, and a likely incidental association with superior plating fixation, were associated with an increased rate of this injury pattern. Ipsilateral clavicle fracture and AC joint injury is much more common than traditionally believed, with an incidence of 6.8% overall. It is unknown how the presence of an associated AC injury influences outcome, as AC injury was not universally symptomatic. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Morphology and structure of Homo erectus humeri from Zhoukoudian, Locality 1

    Directory of Open Access Journals (Sweden)

    Song Xing

    2018-01-01

    Full Text Available Background Regional diversity in the morphology of the H. erectus postcranium is not broadly documented, in part, because of the paucity of Asian sites preserving postcranial fossils. Yet, such an understanding of the initial hominin taxon to spread throughout multiple regions of the world is fundamental to documenting the adaptive responses to selective forces operating during this period of human evolution. Methods The current study reports the first humeral rigidity and strength properties of East Asian H. erectus and places its diaphyseal robusticity into broader regional and temporal contexts. We estimate true cross-sectional properties of Zhoukoudian Humerus II and quantify new diaphyseal properties of Humerus III using high resolution computed tomography. Comparative data for African H. erectus and Eurasian Late Pleistocene H. sapiens were assembled, and new data were generated from two modern Chinese populations. Results Differences between East Asian and African H. erectus were inconsistently expressed in humeral cortical thickness. In contrast, East Asian H. erectus appears to exhibit greater humeral robusticity compared to African H. erectus when standardizing diaphyseal properties by the product of estimated body mass and humeral length. East Asian H. erectus humeri typically differed less in standardized properties from those of side-matched Late Pleistocene hominins (e.g., Neanderthals and more recent Upper Paleolithic modern humans than did African H. erectus, and often fell in the lower range of Late Pleistocene humeral rigidity or strength properties. Discussion Quantitative comparisons indicate that regional variability in humeral midshaft robusticity may characterize H. erectus to a greater extent than presently recognized. This may suggest a temporal difference within H. erectus, or possibly different ecogeographical trends and/or upper limb loading patterns across the taxon. Both discovery and analysis of more adult H

  3. Total elbow arthroplasty in distal humerus fracture in patients older than 65 years.

    Directory of Open Access Journals (Sweden)

    Gerardo Gallucci

    2016-05-01

    Full Text Available Objective To report the clinical-functional results of the treatment of humeral distal fractures with a total elbow prosthesis in patients older than 65 years old. Material and methods This retrospective paper was performed in two surgical centers. Criteria inclusion were: patients with humeral distal fractures, > 65 years, operated on with Coonrad-Morrey prostheses, and with a follow-up of  >1 year. Twenty-one patients were included. Twenty were women with an average age of 79 years old. According to AO classification, 13 fractures were type C3, 7 C2 and 1 A2. All patientes were operated on without desinsertion of the extensor mechanism. Average follow-up was 40 months. Results Flexo-extension was 123-17°, with a total arc of mobility of 106° (80 % of the contralateral side. Pain according to AVE was 1. The MEPI was 83 points: 8 patients had excellent results, 11 good, 1 regular and 1 bad. Average DASH score was 24 points. Conclusion Treatment of humeral distal fractures with total elbow arthoplasty in patients older than 65 years old, may lead to a good option of treatment, but indications must be limited to patients with complex fractures, bad bone quality, with osteoporosis and low functional demands.

  4. Resultados do tratamento das fraturas da diáfise do fêmur ipsilaterais às do colo ou transtrocantérica Outcomes in treatment of diaphiseal femur fractures ipsilateral to the neck or transtrocanteric fracture

    Directory of Open Access Journals (Sweden)

    Nelson Astur Neto

    2010-01-01

    Full Text Available OBJETIVO: Avaliação radiográfica, funcional e das complicações do tratamento cirúrgico das fraturas diafisárias do fêmur associadas à fratura transtrocantérica ou do colo do mesmo fêmur. MÉTODOS: De 2002 a 2007 foram tratados 17 pacientes. Eram masculinos 88% e a idade média foi de 31 anos e três meses. Dez (59% apresentavam associação com fratura do colo do fêmur e sete (41% com a fratura transtrocantérica. Foram avaliados a dor residual e a amplitude de movimento articular do quadril e joelho, a consolidação radiográfica e o tipo de implante utilizado, pela avaliação atual e retrospectivamente pelo prontuário, com um seguimento médio de 48 meses. RESULTADOS: Todas as fraturas transtrocantéricas evoluíram para consolidação sem deformidade residual. Das fraturas do colo, três (30% apresentaram retardo da consolidação, e duas consolidaram em varo. Dois pacientes apresentaram retardo de consolidação da fratura diafisária. Todas as fraturas associadas trans-diáfise apresentaram resultado funcional excelente ou bom. Das associadas colo-diáfise, sete (70% apresentaram resultado funcional excelente ou bom, dois regular e um ruim. CONCLUSÃO: As fraturas associadas da diáfise do fêmur com fratura transtrocantérica apresentaram melhor resultado radiográfico e funcional com menos complicações que a associação da fratura diafisária com a fratura do colo do fêmurOBJECTIVE: To perform a radiographic and functional evaluation of the complications of diaphyseal fractures of the femur associated with ipsilateral fractures of the trochanter or the neck of the femur. METHODS: From 2002 to 2007, seventeen patients were treated, of which 88% were men, with a mean age of thirty-one years and three months. Ten (59% had associated fractures of the femoral neck and seven (41% had associated trochanteric fractures. The final range of motion of the hip and knee, the radiographic fracture consolidation, and the type of

  5. Treatment of proximal humerus fractures with locking plates: a systematic review.

    Science.gov (United States)

    Thanasas, Christos; Kontakis, George; Angoules, Antonios; Limb, David; Giannoudis, Peter

    2009-01-01

    Locking plates with special configuration for the anatomic region of the proximal humerus have been introduced recently to address the difficulties of stabilizing proximal humeral fractures. The purpose of this study was to carry out a systematic review of the literature on the efficacy and early to medium term functional results of locking plates for stabilization of proximal humeral fractures. Using the PubMed database, a systematic review of the English and German literature was carried out in order to assess the efficacy and complications related to the use of these plates and the patients' functional outcome, using the key words "locking plates proximal humeral fractures," "angular stability plates proximal humeral fractures," "PHILOS plate," and "LPHP plate." Our criteria for eligibility were clinical studies with more than ten cases followed-up, adult patients, and adequate data provided at least in terms of implant related complications. Articles written in English and German language were included. Exclusion criteria were: studies dealing exclusively with 2-part fractures (since this category has a more favorable outcome); experimental studies; case reports; and, literature other than English or German. Each one of the articles was evaluated for quality of the study using the Structured Effectiveness Quality Evaluation Scale (SEQES). Twelve studies including 791 patients met the inclusion criteria. Patients in these studies continued to improve up to one year, achieving a mean Constant score of 74.3. The incidence of the reported complications was: avascular necrosis 7.9%, screw cut-out 11.6% and re-operation rate 13.7%. The high incidence of cut-out may be secondary to the rigidity of the implant in combination with medial inadequate support, in cases compromised by severe underlying osteoporotic bone. Definition of indications for the use of locking plates and attention on technical aspects of applying them would help optimization of the results

  6. What is the Effect of 90-Degree Double-Plate Fixation with Grafting on Healing of Humeral Shaft Non-unions

    Directory of Open Access Journals (Sweden)

    Mutlu Çobanoğlu

    2016-08-01

    Full Text Available Objective: Our aim was to investigate the clinical and radiological outcomes of double-plate fixation with grafting in the treatment of non-union of humeral shaft fractures. Materials and Methods: We performed a retrospective chart review of patients operated between 2006 and 2012 due to humeral shaft non-union. Patients undergoing surgery with double-plate fixation were included and those treated with external fixator, single plate, intramedullary nails and patients with pathological fractures and infected non-unions were excluded. Surgical intervention via anterolateral or posterior approach included radial nerve identification, decortication and reestablishment of medullary canal followed by compression plating with double-plate fixation and frequent application of autogenous grafts or allografts. Main outcome measures were success rate of non-union repair, rate of re-intervention and complications, range of motion, assessment of pain Visual analogue scale (VAS and function Disabilities of the arm, shoulder and hand (DASH and overall outcome Stewart-Hundley classification. Results: Ten patients were treated with double-plate fixation. The study group included six females and four males aged 36 to 70 years. Union was achieved within 4.5 and 8 months in all cases. The mean preoperative VAS score of 6.1 decreased to 2, postoperatively, with an associated decrease in the mean DASH score from 74.1 to 23.4. Excellent or good results were obtained in nine cases. There was no incidence of radial nerve palsy or infection. Conclusion: Our study provides level 4 evidence of the effectiveness of treating non-union fractures of the humeral shaft with double-plate fixation and grafting in providing good-to-excellent functional results and high union rate without any significant complication.

  7. Primary diaphyseal osteosarcoma in long bones: Imaging features and tumor characteristics

    International Nuclear Information System (INIS)

    Wang, Cheng-Sheng; Yin, Qi-Hua; Liao, Jin-Sheng; Lou, Jiang-Hua; Ding, Xiao-Yi; Zhu, Yan-Bo; Chen, Ke-Min

    2012-01-01

    Objective: This study aims to assess retrospectively the imaging features of diaphyseal osteosarcoma and compare its characteristics with that of metaphyseal osteosarcoma. Materials and methods: Eighteen pathologically confirmed diaphyseal osteosarcomas were reviewed. Images of X-ray (n = 18), CT (n = 12) and MRI (n = 15) were evaluated by two radiologists. Differences among common radiologic findings of X-ray, CT and MRI, and between diaphyseal osteosarcomas and metaphyseal osteosarcomas in terms of tumor characteristics were compared. Results: The common imaging features of diaphyseal osteosarcoma were bone destruction, lamellar periosteal reaction with/without Codman triangle, massive soft tissue mass/swelling, neoplastic bone and/or calcification. CT and MRI had a higher detection rate in detecting bone destruction (P = 0.001) as compared with that of X-ray. X-ray and CT resulted in a higher percentage in detecting periosteal reaction (P = 0.018) and neoplastic bone and/or calcification (P = 0.043) as compared with that of MRI. There was no difference (P = 0.179) in detecting soft tissue mass among three imaging modalities. When comparing metaphyseal osteosarcoma to diaphyseal osteosarcoma, the latter had the following characteristics: a higher age of onset (P = 0.022), a larger extent of tumor (P = 0.018), a more osteolytic radiographic pattern (P = 0.043). Conclusion: As compared with metaphyseal osteosarcoma, diaphysial osteosarcoma is a special location of osteosarcoma with a lower incidence, a higher age of onset, a larger extent of tumor, a more osteolytic radiographic pattern. The osteoblastic and mixed types are diagnosed easily, but the osteolytic lesion should be differentiated from Ewing sarcoma. X-ray, CT and MRI can show imaging features from different aspects with different detection rates.

  8. Surgical treatment of proximal humerus fractures using PHILOS plate

    Directory of Open Access Journals (Sweden)

    Vijay Sharma

    2014-10-01

    Full Text Available 【Abstract】Objective: To evaluate functional outcome and complications of open reduction and internal fixation with proximal humeral internal locking system (PHILOS plate for proximal humerus fractures. Methods: We reviewed 51 patients who underwent open reduction and internal fixation with PHILOS plate between the years 2007 to 2012. There were 35 men and 16 women with a mean age of 38 years (range 24-68. There were 41 patients in the age group of <60 years and 10 patients in the age group of >60 years. According to Neer classification system, 8, 15 and 23 patients had 2-part, 3-part, and 4-part fractures, respectively and 5 patients had 4-part fracture dislocation. All surgeries were carried out at our tertiary care trauma centre. Functional evaluation of the shoulder at final follow-up was done using Constant-Murley score. Results: The mean follow-up period was 30 months (range 12-44 months. Two patients were lost to followup. Of the remaining 49 patients, all fractures were united clinically and radiologically. The mean time for radiological union was 12 weeks (range 8-20 weeks. At the final follow-up the mean Constant-Murley score was 79 (range 50-100. The results were excellent in 25 patients, good in 13 patients, fair in 6 atients and poor in 5 patients. During the follow-up, four cases of varus malunion, one case of subacromial impingement, one case of deep infection, one case of intraarticular screw penetration and one case of failure of fi xation were noted. No cases of avascular necrosis, hardware failure, locking screw loosening or nonunion were noted. Conclusion: PHILOS provides stable fixation in proximal humerus fractures. To prevent potential complications like avascular necrosis, meticulous surgical dissection to preserve vascularity of humeral head is necessary. Key words: Proximal humerus fracture; Fracture fixation, internal; Proximal humeral internal locking system

  9. Fractures of the proximal humerus

    DEFF Research Database (Denmark)

    Brorson, Stig

    2013-01-01

    Fractures of the proximal humerus have been diagnosed and managed since the earliest known surgical texts. For more than four millennia the preferred treatment was forceful traction, closed reduction, and immobilization with linen soaked in combinations of oil, honey, alum, wine, or cerate......, classification of proximal humeral fractures remains a challenge for the conduct, reporting, and interpretation of clinical trials. The evidence for the benefits of surgery in complex fractures of the proximal humerus is weak. In three systematic reviews I studied the outcome after locking plate osteosynthesis...

  10. Diverse Aquatic Adaptations in Nothosaurus spp. (Sauropterygia-Inferences from Humeral Histology and Microanatomy.

    Directory of Open Access Journals (Sweden)

    Nicole Klein

    Full Text Available Mid-diaphyseal cortical bone tissue in humeri of Nothosaurus spp. consists of coarse parallel-fibered bone, finer and higher organized parallel-fibered bone, and lamellar bone. Vascular canals are mainly arranged longitudinally and radially in a dominantly radial system. Blood vessels are represented by simple vascular canals, incompletely lined primary osteons, and fully developed primary osteons. Nothosaurus spp. shows a variety of diaphyseal microanatomical patterns, ranging from thick to very thin-walled cortices. In the early Anisian (Lower Muschelkalk, small- and large-bodied Nothosaurus spp. generally exhibit bone mass increase (BMI. In the middle to late Anisian (Middle Muschelkalk small-bodied nothosaurs retain BMI whereas larger-bodied forms tend to show a decrease in bone mass (BMD. During the latest Anisian to early Ladinian (Upper Muschelkalk, small- and few large-bodied nothosaurs retain BMI, whereas the majority of large-bodied forms exhibit BMD. The stratigraphically youngest nothosaurs document five microanatomical categories, two of which are unique among marine amniotes: One consists of a very heterogeneously distributed spongy periosteal organization, the other of very thin-walled cortices. The functional significance of the two unique microanatomical specializations seen in large-bodied nothosaurs is the reduction of bone mass, which minimizes inertia of the limbs, and thus saves energy during locomotion. Transitions between the various microanatomical categories are rather gradual. Our results suggest that small-bodied Nothosaurus marchicus and other, not further assignable small-bodied nothosaurs seem to have been bound to near-shore, shallow marine environments throughout their evolution. Some large-bodied Nothosaurus spp. followed the same trend but others became more active swimmers and possibly inhabited open marine environments. The variety of microanatomical patterns may be related to taxonomic differences

  11. Fracture Union in Closed Interlocking Nail in Humeral Shaft Fractures

    Directory of Open Access Journals (Sweden)

    Ramji Lal Sahu

    2015-01-01

    Conclusions: The results of the present study indicates that in the presence of proper indications, reamed antegrade intramedullary interlocked nailing appears to be a method of choice for internal fixation of osteoporotic and pathologic fractures.

  12. External fixation of the metacarpal fracture with transcortical pins and fiberglass east in Simmental calf

    International Nuclear Information System (INIS)

    Martins, E.A.N.; Camargo, L.M.

    2003-01-01

    A six-month-old 245 kg male Simmental calf was referred to the Veterinary Hospital in Cuiabá, MT, with closed comminuted diaphyseal fracture in metacarpus. It was given preference to external fixation as means of fracture immobilization, and transcortical pins and fiberglass cast were used. This technique showed effective immobilization of the fracture, less expensive and feasible to be done in the field [pt

  13. Humeral torsion revisited: a functional and ontogenetic model for populational variation.

    Science.gov (United States)

    Cowgill, Libby W

    2007-12-01

    Anthropological interest in humeral torsion has a long history, and several functional explanations for observed variation in the orientation of the humeral head have been proposed. Recent clinical studies have revived this topic by linking patterns of humeral torsion to habitual activities such as overhand throwing. However, the precise functional implications and ontogenetic history of humeral torsion remain unclear. This study examines the ontogeny of humeral torsion in a large sample of primarily immature remains from six different skeletal collections (n = 407). The results of this research confirm that humeral torsion displays consistent developmental variation within all populations of growing children; neonates display relatively posteriorly oriented humeral heads, and the level of torsion declines steadily into adulthood. As in adults, variation in the angle of humeral torsion in immature individuals varies by population, and these differences arise early in development. However, when examined in the context of the developing muscles of the shoulder complex, it becomes apparent that variation in the angle of humeral torsion is not necessarily related to specific habitual activities. Variability in this feature is more likely caused by a generalized functional imbalance between muscles of medial and lateral rotation that can be produced by a wide variety of upper limb activity patterns during growth. (c) 2007 Wiley-Liss, Inc.

  14. Expandable Total Humeral Replacement in a Child with Osteosarcoma

    Directory of Open Access Journals (Sweden)

    Eric R. Henderson

    2015-01-01

    Full Text Available Case. A right-handed 8-year-old female patient presented with a conventional, high-grade osteosarcoma involving her right humerus; through-shoulder amputation was recommended. After consultation, total humerus resection with expandable, total humeral endoprosthesis reconstruction was performed with a sleeve to encourage soft-tissue ingrowth. At three-year follow-up she has received one lengthening procedure and her functional scores are excellent. Conclusion. Total humeral resection and replacement in the pediatric population are rare and although early reports of expandable total humeral endoprosthesis outcomes demonstrate high failure rates, this patient’s success indicates that expandable total humeral replacement is a viable option.

  15. Reconstruction of malunited diaphyseal fractures of the forearm

    OpenAIRE

    Jayakumar, Prakash; Jupiter, Jesse B

    2014-01-01

    The forearm is a complex anatomical and functional unit with unique osseous, soft tissue and articular relationships. Disruption of these important relations can have a significant impact, leading to pain, instability of the radio-ulnar articulation and reduced range of motion. The gold standard for treating forearm fractures in adults remains anatomic reduction, stable plate fixation and preservation of the surrounding blood supply. Failure to achieve these goals may lead to malunion, requir...

  16. Ingenious method of external fixator use to maintain alignment for nailing a proximal tibial shaft fracture.

    Science.gov (United States)

    Behera, Prateek; Aggarwal, Sameer; Kumar, Vishal; Kumar Meena, Umesh; Saibaba, Balaji

    2015-09-01

    Fractures of the tibia are one of the most commonly seen orthopedic injuries. Most of them result from a high velocity trauma. While intramedullary nailing of tibial diaphyseal fractures is considered as the golden standard form of treatment for such cases, many metaphyseal and metaphyseal-diaphyseal junction fractures can also be managed by nailing. Maintenance of alignment of such fractures during surgical procedure is often challenging as the pull of patellar tendon tends to extend the proximal fragment as soon as one flexes the knee for the surgical procedure. Numerous technical modifications have been described in the literature for successfully nailing such fractures including semi extended nailing, use of medial plates and external fixators among others. In this study, it was aimed to report two cases in which we used our ingenious method of applying external fixator for maintaining alignment of the fracture and aiding in the entire process of closed intramedullary nailing of metaphyseal tibial fractures by the conventional method. We were able to get good alignment during and after the closed surgery as observed on post-operative radiographs and believe that further evaluation of this technique may be of help to surgeons who want to avoid other techniques.

  17. Staphylococcal diaphyseal subacute osteomyelitis of the ulna in a child: an unusual cause of post-traumatic forearm swelling.

    LENUS (Irish Health Repository)

    Kearns, S R

    2004-01-01

    Paediatric subacute osteomyelitis (SAO) presents a diagnostic and therapeutic challenge to clinicians. Typically located in the metaphysis of long bones, diaphyseal SAO of the upper limb is rare. We present the case of a three-year-old girl referred to our fracture clinic as an occult fracture following trauma to her forearm with normal initial radiographs. Follow-up radiographs one week later showed cortical erosion of the distal ulna, while a subsequent MRI scan showed soft tissue swelling with an area of high signal in the distal ulna. A limited biopsy diagnosed staphylococcal subacute osteomyelitis of the ulna. The patient responded to high dose antibiotic therapy and made a full recovery. We present this case to highlight the high index of suspicion required to diagnose and appropriately manage this insidious condition, which may easily be confused with any number of benign and malignant bony lesions and provide a review of the relevant literature.

  18. Bilateral humeral lengthening in achondroplasia with unilateral external fixators: is it safe and does it improve daily life?

    Science.gov (United States)

    Balci, H I; Kocaoglu, M; Sen, C; Eralp, L; Batibay, S G; Bilsel, K

    2015-11-01

    A retrospective study was performed in 18 patients with achondroplasia, who underwent bilateral humeral lengthening between 2001 and 2013, using monorail external fixators. The mean age was ten years (six to 15) and the mean follow-up was 40 months (12 to 104). The mean disabilities of the arm, shoulder and hand (DASH) score fell from 32.3 (20 to 40) pre-operatively to 9.4 (6 to 14) post-operatively (p = 0.037). A mean lengthening of 60% (40% to 95%) was required to reach the goal of independent perineal hygiene. One patient developed early consolidation, and fractures occurred in the regenerate bone of four humeri in three patients. There were three transient radial nerve palsies. Humeral lengthening increases the independence of people with achondroplasia and is not just a cosmetic procedure. ©2015 The British Editorial Society of Bone & Joint Surgery.

  19. Rate of avascular necrosis and time to surgery in proximal humerus fractures.

    Science.gov (United States)

    Archer, L A; Furey, A

    2016-12-01

    Avascular necrosis (AVN) of the humeral head is a devastating complication of proximal humeral fracture (PHF) that often results in long-term morbidity for the patient. Rates of AVN depend on the number of fracture fragments and are highly variable. The literature suggests that timely stable and anatomic reduction may decrease the rate at which AVN develops after PHF. To our knowledge, there is no literature published investigating a temporal relationship between the timing of PHF fixation and rates of AVN. Operative records of one orthopedic trauma surgeon were used to identify patients that underwent open reduction internal fixation for PHF at our institution between 2007 and 2012. Radiographs at presentation were reviewed and used to classify the fractures into two, three or four parts. Date and time of the initial radiograph were recorded as were the date and time of available intra-operative fluoroscopic images. The time from presentation radiograph to operative fixation was calculated (hours). Available follow-up plain films were then reviewed and evaluated for the presence or absence of humeral head AVN. Time to surgery (less than or greater than 72 h) and patient age did not correlate with development of AVN after PHF (p > 0.26). Notably, the number of fracture fragments did influence the rate of AVN identified in patients with PHF (p = 0.002). Early operative intervention does not appear to decrease the rate of development of avascular necrosis after PHF.

  20. Traumatic Foot Fractures in Hard Working Donkeys

    Directory of Open Access Journals (Sweden)

    M.A. Semieka

    2012-10-01

    Full Text Available The present study was carried out on 45 hard working donkeys suffering from different types of traumatic foot fractures. These animals were selected from the clinical cases admitted to the Veterinary Teaching Hospital, Assiut University during the period of 2007-2010. Based on history, clinical signs and radiographic examination, various types of traumatic foot fractures were diagnosed and recorded. These fractures were affect metacarpal bones (N. =16, metatarsal bones (N. =9, proximal phalanx (N. = 13, middle phalanx (N. = 3, distal phalanx (N. = 2 and proximal sesamoid bones (N. = 2. It could be concluded that fractures of the large metacarpal bones are the most common types followed by fractures of the proximal phalanx of the thoracic limb then fractures of the metatarsal bones. Fractures of the middle phalanx, distal phalanx and proximal sesamoid bone are less common in donkeys. Single fractures of the metacarpal and metatarsal bones are more common than comminuted one, in addition diaphyseal fractures of these bones are more common than metaphyseal or epiphyseal fractures. In the proximal phalanx, comminuted fractures are more common than single fractures.

  1. The Changed Route of Anterior Tibial Artery due to Healed Fracture

    Directory of Open Access Journals (Sweden)

    Kemal Gökkuş

    2016-01-01

    Full Text Available We would like to highlight unusual sequelae of healed distal third diaphyseal tibia fracture that was treated conservatively 36 years ago, in which we incidentally detected peripheral CT angiography. The anterior tibial artery was enveloped three-quarterly by the healing callus of the bone (distal tibia.

  2. Ballistic fractures: indirect fracture to bone.

    Science.gov (United States)

    Dougherty, Paul J; Sherman, Don; Dau, Nathan; Bir, Cynthia

    2011-11-01

    Two mechanisms of injury, the temporary cavity and the sonic wave, have been proposed to produce indirect fractures as a projectile passes nearby in tissue. The purpose of this study is to evaluate the temporal relationship of pressure waves using strain gauge technology and high-speed video to elucidate whether the sonic wave, the temporary cavity, or both are responsible for the formation of indirect fractures. Twenty-eight fresh frozen cadaveric diaphyseal tibia (2) and femurs (26) were implanted into ordnance gelatin blocks. Shots were fired using 9- and 5.56-mm bullets traversing through the gelatin only, passing close to the edge of the bone, but not touching, to produce an indirect fracture. High-speed video of the impact event was collected at 20,000 frames/s. Acquisition of the strain data were synchronized with the video at 20,000 Hz. The exact time of fracture was determined by analyzing and comparing the strain gauge output and video. Twenty-eight shots were fired, 2 with 9-mm bullets and 26 with 5.56-mm bullets. Eight indirect fractures that occurred were of a simple (oblique or wedge) pattern. Comparison of the average distance of the projectile from the bone was 9.68 mm (range, 3-20 mm) for fractured specimens and 15.15 mm (range, 7-28 mm) for nonfractured specimens (Student's t test, p = 0.036). In this study, indirect fractures were produced after passage of the projectile. Thus, the temporary cavity, not the sonic wave, was responsible for the indirect fractures.

  3. Biomechanical properties of orthogonal plate configuration versus parallel plate configuration using the same locking plate system for intra-articular distal humeral fractures under radial or ulnar column axial load.

    Science.gov (United States)

    Kudo, Toshiya; Hara, Akira; Iwase, Hideaki; Ichihara, Satoshi; Nagao, Masashi; Maruyama, Yuichiro; Kaneko, Kazuo

    2016-10-01

    Previous reports have questioned whether an orthogonal or parallel configuration is superior for distal humeral articular fractures. In previous clinical and biomechanical studies, implant failure of the posterolateral plate has been reported with orthogonal configurations; however, the reason for screw loosening in the posterolateral plate is unclear. The purpose of this study was to evaluate biomechanical properties and to clarify the causes of posterolateral plate loosening using a humeral fracture model under axial compression on the radial or ulnar column separately. And we changed only the plate set up: parallel or orthogonal. We used artificial bone to create an Association for the Study of Internal Fixation type 13-C2.3 intra-articular fracture model with a 1-cm supracondylar gap. We used an anatomically-preshaped distal humerus locking compression plate system (Synthes GmbH, Solothurn, Switzerland). Although this is originally an orthogonal plate system, we designed a mediolateral parallel configuration to use the contralateral medial plate instead of the posterolateral plate in the system. We calculated the stiffness of the radial and ulnar columns and anterior movement of the condylar fragment in the lateral view. The parallel configuration was superior to the orthogonal configuration regarding the stiffness of the radial column axial compression. There were significant differences between the two configurations regarding anterior movement of the capitellum during axial loading of the radial column. The posterolateral plate tended to bend anteriorly under axial compression compared with the medial or lateral plate. We believe that in the orthogonal configuration axial compression induced more anterior displacement of the capitellum than the trochlea, which eventually induced secondary fragment or screw dislocation on the posterolateral plate, or nonunion at the supracondylar level. In the parallel configuration, anterior movement of the capitellum or

  4. [Clinical experience with various techniques integrated treat the wounded with gunshot fractures of limbs].

    Science.gov (United States)

    Kozlov, V K; Akhmedov, B G; Chililov, A M

    To increase an efficiency of complex treatment of patients with diaphyseal gunshot fractures of long bones by introduction of modern minimally invasive surgical techniques of internal osteosynthesis into clinical practice of civil health care and to improve the outcomes in victims. Prospective comparative clinical trial included 104 victims from the Republic of Yemen with gunshot wounds of limbs of various severity for the period 2009-2011. There were diaphyseal fractures of long bones of limbs associated with soft tissue injuries. Men were predominant (80.7%). Age ranged from 15 to 80 years (mean 38,5 ± 5,7 years). Various surgical techniques of simultaneous and staged treatment were used for gunshot fractures of long bones of limbs. Additional immune therapy was prescribed to prevent infectious complications in the most severe cases. Victims were comprehensively treated according to different staged treatment: conventional surgical treatment with external fixation devices or early primary minimally invasive functionally stable osteosynthesis with LCP/BIOS plates were applied for low-energy fractures; in case of high-energy fractures the first stage included external fixation devices deployment followed by their subsequent replacement during delayed minimally invasive osteosynthesis. The essence of improvement is pursuit to simultaneous minimally invasive surgery by using of current plates for osteosynthesis and preventive immunotherapy of immune dysfunction to eliminate infectious complications. As a result, we obtained 2-fold decrease of surgical invasiveness (r≤0,01) and hospital-stay (r≤0,01). Repeated osteosynthesis was not made. Also 4-fold and 40-fold reduction of infectious and noninfectious complications was observed. This management was accompanied by reduced rehabilitation tine and significantly improved quality of life. Improved technique and algorithm of complex treatment of diaphyseal gunshot fractures of long bones of limbs were described

  5. Clavicle fractures - incidence of supraclavicular nerve injury

    Directory of Open Access Journals (Sweden)

    Pedro Jose Labronici

    2013-08-01

    Full Text Available OBJECTIVE: To analyze retrospectively 309 fractures in the clavicle and the relation with injury of the supraclavicular nerve after trauma. METHODS: It was analyzed 309 patients with 312 clavicle fractures. The Edinburgh classification was used. Four patients had fractures in the medial aspect of the clavicle, 33 in the lateral aspect and 272 in the diaphyseal aspect and three bilateral fractures. RESULTS: 255 patients were analyzed and five had paresthesia in the anterior aspect of the thorax. Four patients had type 2 B2 fracture and one type 2 B1 fracture. All patients showed spontaneous improvement, in the mean average of 3 months after the trauma. CONCLUSION: Clavicle fractures and/ or shoulder surgeries can injure the lateral, intermediary or medial branches of the supraclavicular nerve and cause alteration of sensibility in the anterior aspect of the thorax. Knowledge of the anatomy of the nerve branches helps avoid problems in this region.

  6. Clinical evaluation of a new custom offset shoulder prosthesis for treatment of complex fractures of the proximal humerus

    DEFF Research Database (Denmark)

    Mehlhorn, Alexander T; Schmal, Hagen; Sudkamp, Norbert P

    2006-01-01

    ). The Constant-Murley-Score and radiological score according to Neer's classification were used for postoperative functional and radiological assessment. Following hemiarthroplasty, Group A achieved an average Constant Score of 52 and Group B of 46. The pain relief after hemiarthroplasty was about 53% in Group......Primary hemiarthroplasty of the shoulder is an accepted procedure to treat complex proximal humeral fractures. The goal of this study was to assess the functional outcome in patients treated with hemiarthroplasty using a custom offset shoulder prosthesis, either for an acute four-part fracture...... of the proximal humerus or following failed primary treatment of a complex humeral fracture. Thirty seven patients were followed up for a mean of 17 months after shoulder replacement (Group A: four-part-fractures; n = 26, Group B: posttraumatic necrosis/non-union after failed primary treatment; n = 11...

  7. Double line sign: a helpful sonographic sign to detect occult fractures of the proximal humerus

    Energy Technology Data Exchange (ETDEWEB)

    Rutten, Matthieu J.C.M.; Jager, Gerrit J. [Jeroen Bosch Hospital, Department of Radiology, Hertogenbosch (Netherlands); Waal malefijt, Maarten C. de [University Medical Center Nijmegen, Department of Orthopedic Surgery, Nijmegen (Netherlands); Blickman, Johan G. [University Medical Center Nijmegen, Department of Radiology, Nijmegen (Netherlands)

    2007-03-15

    The aim of this study was to describe a new sonographic sign of bone fracture and to determine if it can be helpful in decreasing the number of missed fractures of the proximal humerus. Ultrasound (US) of the shoulder was performed in 57 consecutive patients with shoulder pain and/or disability following trauma. All cases were prospectively reviewed for the presence of a humeral fracture. Sonographic signs of fractures, with special emphasis on what was termed the 'double line sign' (DLS), were assessed. Plain radiography was considered the standard of reference and in equivocal cases magnetic resonance imaging (MRI). Twenty-eight patients had a tuberosity complex fracture, which were all detected at US examination. Sonographic features of a fracture were periosteal elevation, corticol bone discontinuity, step-off deformity or a combination of these findings. This study showed that in 26 (93%) patients an additional sonographic feature, a DLS, could be demonstrated. The DLS is a helpful and probably reliable sonographic sign to indicate a humeral fracture. High-spatial-resolution US substantially increases the detection of fractures of the proximal humerus and should be considered as an alternative diagnostic tool prior to computed tomography (CT), MRI and arthroscopy in patients with persisting shoulder pain and/or disability following trauma. (orig.)

  8. Double line sign: a helpful sonographic sign to detect occult fractures of the proximal humerus

    International Nuclear Information System (INIS)

    Rutten, Matthieu J.C.M.; Jager, Gerrit J.; Waal malefijt, Maarten C. de; Blickman, Johan G.

    2007-01-01

    The aim of this study was to describe a new sonographic sign of bone fracture and to determine if it can be helpful in decreasing the number of missed fractures of the proximal humerus. Ultrasound (US) of the shoulder was performed in 57 consecutive patients with shoulder pain and/or disability following trauma. All cases were prospectively reviewed for the presence of a humeral fracture. Sonographic signs of fractures, with special emphasis on what was termed the 'double line sign' (DLS), were assessed. Plain radiography was considered the standard of reference and in equivocal cases magnetic resonance imaging (MRI). Twenty-eight patients had a tuberosity complex fracture, which were all detected at US examination. Sonographic features of a fracture were periosteal elevation, corticol bone discontinuity, step-off deformity or a combination of these findings. This study showed that in 26 (93%) patients an additional sonographic feature, a DLS, could be demonstrated. The DLS is a helpful and probably reliable sonographic sign to indicate a humeral fracture. High-spatial-resolution US substantially increases the detection of fractures of the proximal humerus and should be considered as an alternative diagnostic tool prior to computed tomography (CT), MRI and arthroscopy in patients with persisting shoulder pain and/or disability following trauma. (orig.)

  9. Inter- and intraobserver reliability of the MTM-classification for proximal humeral fractures

    DEFF Research Database (Denmark)

    Bahrs, Christian; Schmal, Hagen; Lingenfelter, Erich

    2008-01-01

    tool. METHODS: Three observers classified plain radiographs of 22 fractures using both a simple version (fracture displacement, number of parts) and an extensive version (individual topographic fracture type and morphology) of the MTM classification. Kappa-statistics were used to determine reliability....... RESULTS: An acceptable reliability was found for the simple version classifying fracture displacement and fractured main parts. Fair interobserver agreement was found for the extensive version with individual topographic fracture type and morphology. CONCLUSION: Although the MTM-classification covers...

  10. Displaced proximal humeral fractures: an Indian experience with locking plates

    Directory of Open Access Journals (Sweden)

    Aggarwal Sameer

    2010-08-01

    Full Text Available Abstract Background The treatment of displaced proximal humerus fractures, especially in elderly, remains controversial. The objective of this study was to evaluate functional outcome of locking plate used for fixation of these fractures after open reduction. We also attempted to evaluate the complications and predictors of loss of fixation for such an implant. Methods Over two and a half years, 56 patients with an acute proximal humerus fracture were managed with locking plate osteosynthesis. 47 of these patients who completed a minimum follow up of 1 year were evaluated using Constant score calculation. Statistical analysis was done using SPSS 16 and a p value of less than 0.05 was taken as statistically significant. Results The average follow up period was around 21.5 months. Outcomes were excellent in 17%, good in 38.5%, moderate in 34% while poor in 10.5%. The Constant score was poorer for AO-OTA type 3 fractures as compared to other types. The scores were also inferior for older patients (> 65 years old. Complications included screw perforation of head, AVN, subacromial impingement, loss of fixation, axillary nerve palsy and infection. A varus malalignment was found to be a strong predictor of loss of fixation. Conclusion Locking plate osteosynthesis leads to satisfactory functional outcomes in all the patients. Results are better than non locking plates in osteoporotic fractures of the elderly. However the surgery has steep learning curve and various complications could be associated with its use. Nevertheless we believe that a strict adherence to the principles of locking plate use can ensure good result in such challenging fractures.

  11. Evaluation and treatment of an adult quarter horse with an unusual fracture of the humerus and septic arthritis

    OpenAIRE

    Mitchell, Colin; Riley, Christopher B.

    2002-01-01

    Humeral fractures are rare and usually carry a guarded prognosis in adult horses. This paper describes the evaluation and the successful surgical management of a fracture of the lateral supracondyloid crest and part of the epicondyle of the humerus in an adult quarter horse.

  12. Honey preserved cortical allografts in the repair of diaphyseal femoral defect in dogs: clinical and radiographic

    International Nuclear Information System (INIS)

    Alievi, Marcelo Meller; Wallau Schossler, João Eduardo; Christo de Oliveira, Ana Néri; Almeida Ferreira, Carolina Kist TraeslelIV Patrícia; Dambrósio Guimarães, Luciana

    2007-01-01

    Fourteen adult mongrel dogs were used to evaluate the honey preserved cortical allografts in the repair of diaphyseal femoral defect. The allografts were inserted into a 5cm segmental defect created in the mid-diaphysis of the right femur in each dog. The bones were stabilized with a dynamic compression plate and eight bone screws. Healing was followed clinically and femora were evaluated radiographically, periodically. Nineteen (79.2%) of the twenty-four host-graft interfaces were radiographically incorporated. Average time to allograft incorporation was 67.1 days (range 45 days to 90 days). There was no statistical difference in the allograft incorporation time between proximal and distal host-graft interfaces. Complications observed were nonunion, allograft fracture, and allograft resorption. The conclusion is that despite the complications, honey preserved cortical allografts are a viable option to bone reconstruction [pt

  13. Spatial mapping of humeral head bone density.

    Science.gov (United States)

    Alidousti, Hamidreza; Giles, Joshua W; Emery, Roger J H; Jeffers, Jonathan

    2017-09-01

    Short-stem humeral replacements achieve fixation by anchoring to the metaphyseal trabecular bone. Fixing the implant in high-density bone can provide strong fixation and reduce the risk of loosening. However, there is a lack of data mapping the bone density distribution in the proximal humerus. The aim of the study was to investigate the bone density in proximal humerus. Eight computed tomography scans of healthy cadaveric humeri were used to map bone density distribution in the humeral head. The proximal humeral head was divided into 12 slices parallel to the humeral anatomic neck. Each slice was then divided into 4 concentric circles. The slices below the anatomic neck, where short-stem implants have their fixation features, were further divided into radial sectors. The average bone density for each of these regions was calculated, and regions of interest were compared using a repeated-measures analysis of variance with significance set at P density was found to decrease from proximal to distal regions, with the majority of higher bone density proximal to the anatomic neck of the humerus (P density increases from central to peripheral regions, where cortical bone eventually occupies the space (P density distribution in the medial calcar region was also observed. This study indicates that it is advantageous with respect to implant fixation to preserve some bone above the anatomic neck and epiphyseal plate and to use the denser bone at the periphery. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  14. Significance of the Lateral Humeral Line for Evaluating Radiocapitellar Alignment in Children.

    Science.gov (United States)

    Souder, Christopher D; Roocroft, Joanna H; Edmonds, Eric W

    The radiocapitellar line (RCL) was originally described for evaluation of the alignment of the RC joint on lateral images of the elbow. Although, many authors have translated the utilization of RCL into coronal imaging, previous studies have not been performed to confirm validity. The purpose of this paper was to identify an accurate way of evaluating pediatric RC alignment in the coronal plane. Thirty-seven anteroposterior (AP) radiographs of 37 children were evaluated to determine the position of the RC joint in the coronal plane. All had acceptable magnetic resonance imaging (MRI) studies available for comparison. The lateral humeral line (LHL), consisting of a line along the lateral edge of the ossified condyle of the distal humerus parallel to the axis of the distal humeral shaft, was studied as it related to the lateral cortex of the radial neck. Three children with a confirmed diagnosis of a Bado III, lateral displaced radius, Monteggia fracture were also evaluated. The LHL passed along the edge of or lateral to the radial neck on all AP radiographs and all MRI studies. The RCL failed to intersect the capitellum on 2 AP radiographs. On MRI, the RCL also passed lateral to the capitellar ossification center in 3 patients. In addition, the RCL was seen passing through the capitellum at a mean of the lateral 30% (range, 0% to 64%) on AP radiographs and 26% (range, 0% to 48%) on MRI. For all 3 children with a Bado III Monteggia fracture, the LHL crossed the radial neck and the RCL did not intersect the capitellum. The RCL can fail to intersect the capitellar ossification center on AP radiographs and MRI in pediatric elbows without injury. The LHL consistently lies lateral to the radial neck in normal elbows and medial to the lateral aspect of the radial neck on all Bado III fracture-dislocations. It, therefore, can be used as an adjunct in evaluating the RC joint on AP imaging. The RCL most commonly intersects the lateral one third of the ossification center on

  15. [Imaging evaluation on adaptability of proximal humeral anatomy after shoulder replacement with individualized shoulder prosthesis].

    Science.gov (United States)

    Shi, Youxing; Tang, Kanglai; Yuan, Chengsong; Tao, Xu; Wang, Huaqing; Chen, Bo; Guo, Yupeng

    2015-03-24

    Modern shoulder prosthesis has evolved through four generations. And the fourth generation technology has a core three-dimensional design of restoring 3D reconstruction of proximal humeral anatomy. Thus a new shoulder prosthesis is developed on the basis of the technology of 3D prosthesis. Assessment of whether shoulder prosthesis can restore individualized reconstruction of proximal humeral anatomy is based on the adaptability of proximal humeral anatomy. To evaluate the adaptability of proximal humeral anatomy through measuring the parameters of proximal humeral anatomy after shoulder replacement with individualized shoulder prosthesis and compare with normal data. The parameters of proximal humeral anatomy were analyzed and evaluated for a total of 12 cases undergoing shoulder replacement with individualized shoulder prosthesis. The relevant anatomical parameters included neck-shaft angle (NSA), retroversion angle (RA), humeral head height (HH) and humeral head diameter (HD). And the anatomical parameters were compared with the data from normal side. All underwent shoulder replacement with individualized shoulder prosthesis. The postoperative parameters of proximal humeral anatomy were compared with those of normal side. And the difference of NSA was 0.05). Individualized shoulder prosthesis has excellent adaptability to shoulder. All core parameters are freely adjustable and specification models may be optimized. With matching tools, individualized shoulder prosthesis improves the accuracy and reliability in shoulder replacement.

  16. Outcomes of the distal intraarticular humeral fractures treated by olecranon osteotomy

    Directory of Open Access Journals (Sweden)

    Erhan Yılmaz

    2009-01-01

    Full Text Available Objectives: To evaluate the management and outcome of intraarticular fractures of the distal humerus treated by open reduction and internal fixation using the olecranon osteotomy technique. Materials and methods: Twenty-one patients with in-traarticular fractures of the distal humerus were treated by open reduction and internal fixation. The mean age of the patients was 41.6 years and the mean follow-up pe-riod was 25.3 months. All fractures were type C accord-ing to the AO/ASIF fracture classification system. Chev-ron type olecranon osteotomy was performed within 12-24 h after the injury in all cases but 4 of them. Physical and radiological examination of patients with the appro-priate range checks were made.Results: All fractures united within average duration of 3.2 months. Excellent or good results were found in pa-tients less than 50 years-old, in women, when passing time from injury to surgery was within 12 hours and when early mobilization was achieved. The complica-tions were seen as 2 (9.6% transient neuropraxia of the ulnar nerve, 2 (9.6% failure of fixation, 1 (4.8% het-erotopic ossification and 1 (4.8% olecranon non-union. Fracture type (C1 and time from occurrence of injury to surgery (<12 hours are the main prognostic factors for achieving the excellent/ good functional results.Conclusions: The critical factors for a successful out-come of intraarticular fractures of the distal humerus in-cluded meticulous surgical technique, stable internal fix-ation, surgical experimentation and early controlled postoperative mobilization.

  17. The relationship of glenoid and humeral version with supraspinatus tendon tears

    Energy Technology Data Exchange (ETDEWEB)

    Tokgoz, Nil; Kadioglu Voyvoda, Nuray; Gultekin, Serap; Tali, E.T. [Gazi University School of Medicine, Department of Radiology, Ankara (Turkey); Kanatli, Ulunay; Bolukbasi, Selcuk [Gazi University School of Medicine, Department of Orthopaedic Surgery, Ankara (Turkey)

    2007-06-15

    The aim of this study was to investigate the relationship of glenohumeral anatomic measurements on MR imaging with supraspinatus tendon tears. The study was approved by the institutional review board and informed consent was obtained from each subject. Forty-two patients (mean age 55.5 years; age range 40-73 years) with supraspinatus tendon tears and 50 asymptomatic shoulders of 32 controls (mean age 43 years; age range 17-69 years) without rotator cuff tears were included. The acromio-glenoid and supraspinatus-glenoid angles were measured on coronal images, the glenoid and humeral head version as well as the bicipital-humeral distance on axial images. Significant differences were found between the patients and controls for both glenoid version and bicipital-humeral distance, which are considered to influence the distribution of forces placed on the cuff (p < 0.05). The patients had a decreased glenoid version by an average of 2.3 (-7.1 {+-} 7.8 vs. -4.8 {+-} 5.6 ), and a decreased bicipital-humeral distance by an average of 2.7 mm (12.1 {+-} 3.7 mm vs. 14.8 {+-} 4.1 mm). No significant differences were found between these groups for humeral head version and the acromio-glenoid and supraspinatus-glenoid angles, which might contribute to extrinsic impingement by narrowing the supraspinatus tendon outlet. Differences in glenoid and humeral version may be responsible for RC tears by changing the orientation of the rotator cuff and thus increasing shearing stress. (orig.)

  18. The relationship of glenoid and humeral version with supraspinatus tendon tears

    International Nuclear Information System (INIS)

    Tokgoz, Nil; Kadioglu Voyvoda, Nuray; Gultekin, Serap; Tali, E.T.; Kanatli, Ulunay; Bolukbasi, Selcuk

    2007-01-01

    The aim of this study was to investigate the relationship of glenohumeral anatomic measurements on MR imaging with supraspinatus tendon tears. The study was approved by the institutional review board and informed consent was obtained from each subject. Forty-two patients (mean age 55.5 years; age range 40-73 years) with supraspinatus tendon tears and 50 asymptomatic shoulders of 32 controls (mean age 43 years; age range 17-69 years) without rotator cuff tears were included. The acromio-glenoid and supraspinatus-glenoid angles were measured on coronal images, the glenoid and humeral head version as well as the bicipital-humeral distance on axial images. Significant differences were found between the patients and controls for both glenoid version and bicipital-humeral distance, which are considered to influence the distribution of forces placed on the cuff (p < 0.05). The patients had a decreased glenoid version by an average of 2.3 (-7.1 ± 7.8 vs. -4.8 ± 5.6 ), and a decreased bicipital-humeral distance by an average of 2.7 mm (12.1 ± 3.7 mm vs. 14.8 ± 4.1 mm). No significant differences were found between these groups for humeral head version and the acromio-glenoid and supraspinatus-glenoid angles, which might contribute to extrinsic impingement by narrowing the supraspinatus tendon outlet. Differences in glenoid and humeral version may be responsible for RC tears by changing the orientation of the rotator cuff and thus increasing shearing stress. (orig.)

  19. Total Humeral Endoprosthetic Replacement following Excision of Malignant Bone Tumors

    Directory of Open Access Journals (Sweden)

    Suhel Kotwal

    2016-01-01

    Full Text Available Humerus is a common site for malignant tumors. Advances in adjuvant therapies and reconstructive methods provide salvage of the upper limb with improved outcomes. Reports of limb salvage with total humeral replacement in extensive humeral tumors are sparse. We undertook a retrospective study of 20 patients who underwent total humeral endoprosthetic replacement as limb salvage following excision of extensile malignant tumor from 1990 to 2011. With an average followup of 42.9, functional and oncological outcomes were analyzed. Ten patients were still alive at the time of review. Mean estimated blood loss was 1131 mL and duration of surgery was 314 minutes. Deep infection was encountered in one patient requiring debridement while mechanical loosening of ulnar component was identified in one patient. Subluxation of prosthetic humeral head was noted in 3 patients. Mean active shoulder abduction was 12.5° and active flexion was 15°. Incompetence of abduction mechanism was the major determinant of poor active functional outcome. Mean elbow flexion was 103.5° with 30.5° flexion contracture in 10 patients with good and useful hand function. Average MSTS score was 71.5%. Total humeral replacement is a reliable treatment option in restoring mechanical stability and reasonable functional results without compromising patient survival, with low complication rate.

  20. Diagnosing displaced four-part fractures of the proximal humerus

    DEFF Research Database (Denmark)

    Brorson, Stig; Bagger, Jens; Sylvest, Annette

    2009-01-01

    Displaced four-part fractures comprise 2-10 % of all proximal humeral fractures. The optimal treatment is unclear and randomised trials are needed. The conduct and interpretation of such trials is facilitated by a reproducible fracture classification. We aimed at quantifying observer agreement...... on the classification of displaced four-part fractures according to the Neer system. Published and unpublished data from five observer studies were reviewed. Observers agreed less on displaced four-part fractures than on the overall Neer classification. Mean kappa values for interobserver agreement ranged from 0.......16 to 0.48. Specialists agreed slightly more than fellows and residents. Advanced imaging modalities (CT and 3D CT) seemed to contribute more to classification of displaced four-part patterns than in less complex fracture patterns. Low observer agreement may challenge the clinical approach to displaced...

  1. Fractures of the humerus during arm wrestling

    Directory of Open Access Journals (Sweden)

    Bumbaširević Marko Ž.

    2014-01-01

    Full Text Available Background/Aim. Humeral shaft fractures may occur as a result of arm wrestling. The aim of this study was to present our treatment of humerus fracture sustained during arm wrestling. Methods. A total of six patients, aged 22 to 48, were treated at our department form January 2008 to January 2010 with open reduction and internal fixation and with hanging arm casts. A review of all the relevant literature on the subject was also presented. Results. In all the cases, the fractures healed and function returned to normal. No patient had any neural or vascular compromise. Conclusion. Closed and operative treatments were equally successful in all reported cases. [Projekat Ministarstva nauke Republike Srbije, br. 175-095

  2. Management of open tibial fractures – a regional experience

    Science.gov (United States)

    Townley, WA; Nguyen, DQA; Rooker, JC; Dickson, JK; Goroszeniuk, DZ; Khan, MS; Camp, D

    2010-01-01

    INTRODUCTION The treatment of soft-tissue injuries associated with tibial diaphyseal fractures presents a clinical challenge that is best managed by a combined plastic and orthopaedic surgery approach. The current study was undertaken to assess early treatment outcomes and burden of service provision across five regional plastic surgery units in the South-West of England. SUBJECTS AND METHODS We conducted a prospective 6-month audit of open tibial diaphyseal fracture management in five plastic surgery units (Bristol, Exeter, Plymouth, Salisbury, Swansea) with a collective catchment of 9.2 million people. Detailed data were collected on patient demographics, injury pattern, surgical management and outcome followed to discharge. RESULTS The study group consisted of 55 patients (40 male, 15 female). Twenty-two patients presented directly to the emergency department at the specialist hospital (primary group), 33 patients were initially managed at a local hospital (tertiary group). The mean time from injury to soft tissue cover was significantly less (P < 0.001) in the primary group (3.6 ± 0.8 days) than the tertiary group (10.8 ± 2.2 days), principally due to a delay in referral in the latter group (5.4 ±1.7 days). Cover was achieved with 39 flaps (19 free, 20 local), eight split skin grafts. Nine wounds closed directly or by secondary intention. There were 11 early complications (20%) including one flap failure and four infections. The overall mean length of stay was 17.5 ± 2.8 days. CONCLUSIONS Multidisciplinary management of severe open tibial diaphyseal may not be feasible at presentation of injury depending on local hospital specialist services available. Our results highlight the need for robust assessment, triage and senior orthopaedic review in the early post-injury phase. However, broader improvements in the management of lower limb trauma will additionally require further development of combined specialist trauma centres. PMID:21047449

  3. Anatomic humeral head replacement with a press-fit prosthesis: An in vivo radiographic study

    Directory of Open Access Journals (Sweden)

    Bryan Vopat

    2017-10-01

    Full Text Available Successful total shoulder arthroplasty is, in part, dependent on anatomic reconstruction of the glenohumeral joint. The purpose of this study was to evaluate the post-operative anatomy of total shoulder arthroplasty with an anatomic implant design in patients with primary glenohumeral osteoarthritis and compare it to published normative anatomic measurements. Fifty-one patients (56 shoulders with primary glenohumeral osteoarthritis were treated with a press-fit humeral component as part of a total shoulder arthroplasty (Aequalis, Tornier, Edina, Minnesota. Analysis of postoperative true anterior posterior radiographs was performed with use of a custom software algorithm. The mean humeral inclination (head-shaft angle, mean humeral implant anatomical humeral axis, mean greater tuberosity height, and mean humeral head center offset (medial offset were 135.4±5.1°, 1.73±1.7°, 6.9±2.4 mm, and 3.8±1.8 mm, respectively. All parameters were within the ranges reported in the literature for normal shoulders except the mean humeral head center offset, which was less than reported in the literature. Anatomic parameters of a total shoulder arthroplasty can be achieved with an anatomically designed, modular adaptable press-fit design. Reduced medial humeral head center offset was likely dependent upon implant specific design parameters.

  4. Osteosarcoma with a pathologic fracture in a six-month-old dog

    International Nuclear Information System (INIS)

    Phillips, L.; Hager, D.; Parker, R.; Yanik, D.

    1986-01-01

    This case history report describes the clinical, radiographic, and histopathologic features of an osteosarcoma with an associated pathologic fracture in a 6-month-old dog. A 6-month-old intact male Bloodhound was presented with a primary complaint of a right forelimb lameness of one month's duration. In radiographs, a minimally displaced transverse fracture of the proximal humeral metaphysis was seen. There was extensive cortical bone destruction at the fracture site and minimal periosteal new bone suggestive of a primary bone tumor with a pathologic fracture. Biopsy specimens demonstrated neoplastic mesenchymal cells producing osteoid compatible with a diagnosis of osteosarcoma. This case history report constitutes the youngest reported canine osteosarcoma

  5. Resultados de tratamento cirúrgico da pseudoartrose de fratura diafisária do úmero com placa de compressão dinâmica e enxerto de osso esponjoso Results of surgical treatment of nonunion of humeral shaft fracture with dynamic compression plate and cancellous bone grafting

    Directory of Open Access Journals (Sweden)

    Olasinde Anthony Ayotunde

    2012-01-01

    Full Text Available OBJETIVO: Avaliamos o tratamento da pseudoartrose de fratura diafisária do úmero com placa de compressão dinâmica de janeiro de 2002 a dezembro de 2009. MÉTODOS: Vinte e dois pacientes foram tratados durante o período do estudo. O trauma foi a causa predominante de lesão em 86,4% dos pacientes. RESULTADOS: A pseudoartrose foi atrófica em 81,8% e hipertrófica em 18,2% dos indivíduos. Havia lesão primária do nervo radial nervo em 27,3% dos pacientes. Todos os participantes tinham fratura fechada à apresentação e 81,2% deles tinham recebido tratamento anterior de traditional bone setters (pessoa que faz a redução de ossos quebrados ou deslocados, geralmente sem ser médico licenciado e 18,8% tinham falha do tratamento conservador com gesso. O tempo médio até a união foi 16 semanas. O tratamento anterior com traditional bone setters afetou significantemente o tempo de consolidação da fratura (p OBJECTIVE: We evaluated the treatment of nonunion of humeral shaft fracture with dynamic compression plate from January 2002 to December 2009. METHODS: Twenty two patients were treated over the study period. Trauma was the predominant cause of injury in 86,4% of the patients. RESULTS: Nonunion was atrophic in 81,8% and hypertrophic in 18,2% of the individuals. There was a primary injury of the radial nerve in 27,3% of the patients. All the participants had closed fracture at presentation, and 81,2% had received previous treatment from traditional bone setters and 18,8% had failure of the conservative cast management.The average time to healing was 16 weeks. Previous treatment from traditional bone setters significantly affected the time to fracture healing (p<0,05. All fractures had successful union. CONCLUSION: It was concluded that dynamic compression plating remains an effective treatment option for nonunion of humeral shaft fracture. Level of Evidence III, Retrospective study.

  6. Neglected Distal Humeral Epiphyseal Injury - Two Case Reports

    Directory of Open Access Journals (Sweden)

    Dr. Pankaj Kumar

    2008-07-01

    Full Text Available Distal humeral epiphyseal separation is an uncommon injury in children, which can be missed or misdiagnosed at initial presentation. Awareness of this injury and appropriate radiological assessment helps in proper management. Neglected cases because of inappropriate diagnosis can result in cubitus varus deformity. Full range of movements of elbow can be achieved if properly diagnosed and managed. We present two cases of neglected distal humeral epiphyseal injury in children that resulted in cubitus varus deformity in one case. Full range of movements was achieved in both cases after proper management.

  7. Comparative Study Using Intramedullary K-wire Fixation Over Titanium Elastic Nail in Paediatric Shaft Femur Fractures.

    Science.gov (United States)

    Kumar, Sanjiv; Anand, Tushar; Singh, Sudhir

    2014-11-01

    Fracture shaft femur is common paediatric trauma leading to significant morbidity. Conservative treatments available are associated with prolonged periods of immobilization. Use of flexible intramedullary implant allows early rehabilitation in diaphyseal fractures of femur in children. The aim of the present study is to compare fixation of diaphyseal femur fracture by titanium elastic nail and intramedullary K-wires in children. Prospective randomized study in a tertiary care hospital. Fifty-two children between 6 years and 14 years of age with femoral shaft fracture were assigned either in Group I or Group II based on computer generated random numbers. In Group I closed percutaneous intramedullary K- wire fixation and in Group II closed percutaneous intramedullary titanium elastic nail was used to fix the fractures. Partial weight bearing was allowed after 6 weeks of surgery and full weight bearing at clinico-radiological union. Average time of radiological union was 6 to 10 weeks in both groups. In both the groups two cases had entry site irritation which resolved with early implant removal. One case in both the groups had unacceptable mal-alignment. Both the groups had few cases of limb-length discrepancy, which was in acceptable limit, except two cases of TENS. There was no statistically significant difference between the results of both the groups. But, using K-wires significantly reduced the cost of treatment. Most of such fractures in our society are neglected because of high cost of treatment. Providing a cheaper alternative in form of K-wires may be beneficial for the patients from low socio-economic status.

  8. Relationship between blood flow and radiostrontium uptake in the healing bone fracture

    International Nuclear Information System (INIS)

    Schuemichen, C.; Mundriziewski, L.; Tischler, E.; Hoffmann, G.

    1979-01-01

    The healing of a diaphyseal tibia fracture was followed in the rat. Callus formation, blood flow and Sr-85 uptake were assessed by a ratio comparison of the fractured to the contralateral side. No correlation was found between blood flow and Sr-85 deposition in the callus and the adjacent bone of the same extremity. It is concluded that the deposition of a radiopharmaceutical in bone is primarily related to the presence of calcifiable organic bone matrix and only secondarily to the bone formation rate and to variations in the local blood flow. (orig.) 891 MG/orig. 892 MBE [de

  9. [Tibiotalocalcaneal arthrodesis using a humeral locking plate].

    Science.gov (United States)

    Cabrera Méndez, M P; Gamba, C; Hernández, E; Molano, J; Andrade, J C

    2016-01-01

    To describe the results of tibiotalocalcáneal arthrodesis (TTC) using a humeral locking plate. A retrospective, observational study was conducted between January 2007 and December 2013 in the Hospital Militar Central de Bogotá. The study included patients with symptomatic osteoarthritis diagnosed clinically and radiologically, and who underwent TTC arthrodesis using a humeral locking plate with a minimum follow up of 6 months. The total number patients was 35, of whom 7 (20%) were women and 28 (80%) men, with a mean age 36.3 years (19.77). 74% with post-traumatic arthritis, most of them secondary to gunshot wounds and fragmentation weapons, and neuropathic in 20%. An autogenous graft was used in 13 cases, and 14 cases using both, with a mean consolidation time of 4.37 months. Complications include, delayed union in 3 cases, and surgical site infection in 4. The postoperative functionality (AOFAS) mean was 66.7/100 points, with a score of 2.35 on a visual analogue pain scale. TTC arthrodesis using a humeral locking plate is a suitable option for fixing this type of arthrodesis, with a low rate of complications, and postoperative results that revealed satisfactory improvement in pain and consolidation. Copyright © 2015 SECOT. Published by Elsevier Espana. All rights reserved.

  10. [Treatment of type C intercondylar fractures of distal humerus using dual plating].

    Science.gov (United States)

    Liu, Ya-Ke; Xu, Hua; Liu, Fan; Wang, You-Hua; Tao, Ran; Cao, Yi; Wang, Hong; Zhou, Zhen-Yu; Zhu, Yong

    2009-06-15

    To evaluate the clinical outcome of dual plating in the treatment of humeral intercondylar type-C fractures in adults. From June 2004 to October 2007, 38 cases of type-C distal humeral fractures were stabilised with dual plating. There were 21 males and 17 females. The average age was 43 years with a range from 21 to 71 years. According to the AO classification, 9 cases were of type C1, 17 of C2 and 12 of C3. The posterior midline approach was selected. Twenty-one cases were exposed through the trans-olecranon osteotomy, 11 through the Campbell (Van Gorder) approach, 6 through triceps sparing approach. Autogenous bone graft was performed in 5 cases because of severe comminution. Thirty-five patients were followed-up for 14-30 months (mean 24.2 months). At the latest follow-up, the elbow flexion averaged 119 degrees (range 90 degrees - 135 degrees ), and the loss of extension averaged 16.2 degrees (range 5 degrees - 25 degrees ). All the patients got bony healing, the average healing period was 14 weeks. The patients were evaluated using the criteria of Aitken and Rorabeek and the scores were 13 excellent, 16 good, 6 fair. Twenty-nine patients (82.9%) had a good or excellent results. Complications included 4 cases of traumatic osteoarthritis, 2 heterotopic ossification, 1 ulnar neuropathy. Infection as well as loosening or breakage of the implant was not found. The dual plating is able to provide rigid fixation for the humeral intercondylar fractures. In addition, it can allow early functional exercise after operation, decrease the related complications significantly, and improve the functional results.

  11. Exposure to Secondhand Smoke Impairs Fracture Healing in Rats.

    Science.gov (United States)

    Santiago, Hildemberg A R; Zamarioli, Ariane; Sousa Neto, Manoel D; Volpon, Jose B

    2017-03-01

    Nonsmokers may be affected by environmental tobacco smoke (secondhand smoke), but the effects of such exposure on fracture healing have not been well studied. To explore the possible effects of passive inhalation of tobacco smoke on the healing of a diaphyseal fracture in femurs of rats. We hypothesized that secondhand exposure to tobacco smoke adversely affects fracture healing. A mid-diaphyseal fracture was created in the femur of 41 female Wistar rats and fixed with an intramedullary metallic pin; 14 rats were excluded (nine for inadequate fractures and five for K wire extrusion). Tobacco exposure was provided by a smoking machine on a daily basis of four cigarettes a day. Each cigarette yielded 10 mg tar and 0.8 mg nicotine, and was puffed by alternating injections of fresh air for 30 seconds and smoke air for 15 seconds. The smoke exposure was previously adjusted to provide serum levels of cotinine similar to human secondhand tobacco exposure. Cotinine is a predominant catabolite of nicotine that is used as a biological biomarker for exposure to tobacco smoke. In one group (n = 11), the animals were intermittently exposed to tobacco smoke before sustaining the fracture but not afterward. In another group (n = 7), the exposure occurred before and after the fracture. The control group (n = 9) was sham-exposed before and after the fracture. We evaluated the specimens 28 days after bone fracture. The callus quality was measured by dual-energy x-ray absorptiometry (bone mineral density [BMD], bone mineral content [BMC], and callus area), μCT (callus volume and woven bone fraction), and mechanical bending (maximum force and stiffness). Tobacco exposure resulted in delayed bone callus formation, which is represented by decreased BMD (Control: 0.302 ± 0.008 g/cm 2 vs Preexposed: 0.199 ± 0.008 g/cm 2 and Pre- and Postexposed: 0.146 ± 0.009 g/cm 2 ; mean difference = 0.103 g/cm 2 , 95% CI, 0.094-0.112 g/cm 2 and mean difference = 0.156 g/cm 2 , 95% CI, 0.147-0.167 g

  12. Local application of a gentamicin-loaded thermo-responsive hydrogel allows for fracture healing upon clearance of a high Staphylococcus aureus load in a rabbit model

    Directory of Open Access Journals (Sweden)

    G-JA ter Boo

    2018-03-01

    Full Text Available ntibiotic-loaded biomaterials (ALBs have emerged as a potential useful adjunctive antimicrobial measure for the prevention of infection in open fracture care. A biodegradable thermo-responsive poly(N-isopropylacrylamide grafted hyaluronic acid (HApN hydrogel loaded with gentamicin has recently been shown to prevent implant-related infection in a rabbit osteosynthesis model. The primary aim of this study was to determine the influence of this HApN hydrogel on bone healing at an early stage (4 weeks. A rabbit humeral osteotomy model with plating osteosynthesis was used to compare fracture healing in rabbits receiving the hydrogel as compared with control animals. The secondary aim was to observe fracture healing in groups treated with and without antibiotic-loaded hydrogel in the presence of bacterial contamination. In all groups, outcome measures were mechanical stability and histological score, with additional quantitative bacteriology in the inoculated groups. Application of the HApN hydrogel in non-inoculated rabbits did not significantly influence humeral stiffness or histological scores for fracture healing in comparison to controls. In the inoculated groups, animals receiving the bacterial inoculum without hydrogel were culture-positive at euthanasia and found to display lower humeral stiffness values and higher histopathological scores for bacterial presence in comparison with equivalents receiving the gentamicin-loaded HApN hydrogel, which were also infection-free. In summary, our data showed that HApN was an effective antibiotic carrier that did not affect fracture healing. This data supported its suitability for application in fracture care. Addition of osteopromotive compounds could provide further support for accelerating fracture healing in addition to successful infection prophylaxis.

  13. Lower trabecular volumetric BMD at metaphyseal regions of weight-bearing bones is associated with prior fracture in young girls.

    Science.gov (United States)

    Farr, Joshua N; Tomás, Rita; Chen, Zhao; Lisse, Jeffrey R; Lohman, Timothy G; Going, Scott B

    2011-02-01

    Understanding the etiology of skeletal fragility during growth is critical for the development of treatments and prevention strategies aimed at reducing the burden of childhood fractures. Thus we evaluated the relationship between prior fracture and bone parameters in young girls. Data from 465 girls aged 8 to 13 years from the Jump-In: Building Better Bones study were analyzed. Bone parameters were assessed at metaphyseal and diaphyseal sites of the nondominant femur and tibia using peripheral quantitative computed tomography (pQCT). Dual-energy X-ray absorptiometry (DXA) was used to assess femur, tibia, lumbar spine, and total body less head bone mineral content. Binary logistic regression was used to evaluate the relationship between prior fracture and bone parameters, controlling for maturity, body mass, leg length, ethnicity, and physical activity. Associations between prior fracture and all DXA and pQCT bone parameters at diaphyseal sites were nonsignificant. In contrast, lower trabecular volumetric BMD (vBMD) at distal metaphyseal sites of the femur and tibia was significantly associated with prior fracture. After adjustment for covariates, every SD decrease in trabecular vBMD at metaphyseal sites of the distal femur and tibia was associated with 1.4 (1.1-1.9) and 1.3 (1.0-1.7) times higher fracture prevalence, respectively. Prior fracture was not associated with metaphyseal bone size (ie, periosteal circumference). In conclusion, fractures in girls are associated with lower trabecular vBMD, but not bone size, at metaphyseal sites of the femur and tibia. Lower trabecular vBMD at metaphyseal sites of long bones may be an early marker of skeletal fragility in girls. Copyright © 2011 American Society for Bone and Mineral Research.

  14. Management of fractures of the humerus in Ancient Egypt, Greece, and Rome: an historical review

    DEFF Research Database (Denmark)

    Brorson, Stig

    2009-01-01

    Fractures of the humerus have challenged medical practitioners since the beginning of recorded medical history. In the earliest known surgical text, The Edwin Smith Papyrus (copied circa 1600 BC), three cases of humeral fractures were described. Reduction by traction followed by bandaging......, and multifragmented fractures. In Late Antiquity, complications from powerful traction or tight bandaging were described by Paul of Aegina (circa AD 625-690). Illustrations from sixteenth and seventeenth century surgical texts are included to show the ancient methods of reduction and bandaging. The richness...

  15. Humeral head size in shoulder arthroplasty

    DEFF Research Database (Denmark)

    Vaesel, M T; Olsen, Bo Sanderhoff; Søjbjerg, Jens Ole

    1998-01-01

    Changes in kinematics after hemiarthroplasty of the glenohumeral joint were investigated in nine cadaveric specimens. During experiments the influence of the humeral head size on glenohumeral kinematics was evaluated. A modular prosthesis with five different head sizes and press-fit stems was use...

  16. Surgical interventions to treat humerus shaft fractures: A network meta-analysis of randomized controlled trials.

    Directory of Open Access Journals (Sweden)

    Jia-Guo Zhao

    Full Text Available There are three main surgical techniques to treat humeral shaft fractures: open reduction and plate fixation (ORPF, intramedullary nail (IMN fixation, and minimally invasive percutaneous osteosynthesis (MIPO. We performed a network meta-analysis to compare three surgical procedures, including ORPF, IMN fixation, and MIPO, to provide the optimum treatment for humerus shaft fractures.MEDLINE, EMBASE, Cochrane Bone, Joint and Muscle Trauma Group Specialised Register, and Cochrane library were researched for reports published up to May 2016. We only included randomized controlled trials (RCTs comparing two or more of the three surgical procedures, including the ORPF, IMN, and MIPO techniques, for humeral shaft fractures in adults. The methodological quality was evaluated based on the Cochrane risk of bias tool. We used WinBUGS1.4 to conduct this Bayesian network meta-analysis. We used the odd ratios (ORs with 95% confidence intervals (CIs to calculate the dichotomous outcomes and analyzed the percentages of the surface under the cumulative ranking curve.Seventeen eligible publications reporting 16 RCTs were included in this study. Eight hundred and thirty-two participants were randomized to receive one of three surgical procedures. The results showed that shoulder impingement occurred more commonly in the IMN group than with either ORPF (OR, 0.13; 95% CI, 0.03-0.37 or MIPO fixation (OR, 0.08; 95% CI, 0.00-0.69. Iatrogenic radial nerve injury occurred more commonly in the ORPF group than in the MIPO group (OR, 11.09; 95% CI, 1.80-124.20. There were no significant differences among the three procedures in nonunion, delayed union, and infection.Compared with IMN and ORPF, MIPO technique is the preferred treatment method for humeral shaft fractures.

  17. Closed Tibial shaft fractures treated with the Ilizarov method: A ten year case series.

    Science.gov (United States)

    May, Jonathan David; Paavana, Thumri; McGregor-Riley, Jonathan; Royston, Simon

    2017-07-01

    To review the outcomes of patients treated with the Ilizarov method for an isolated, closed, simple diaphyseal, Tibial fracture at our institution over the last decade. The Ilizarov frame database was used to identify 76 skeletally mature patients who sustained an isolated, closed, extra-articular, simple, diaphyseal Tibial fracture; the injury also known as a "nail-able Tibial fracture." The average age of the patient was 38 (17-70). All 76 patients progressed to union. The average time until union was 148 (55-398) days. The coronal and sagittal alignment was 3° (0-17°) and 4° (0-14°) respectively. No patient suffered from compartment syndrome. No patient developed septic arthritis. No patient had documented anterior knee pain or secondary knee specialist input post frame removal. On average, there were 9(4-29) follow up appointments and 10(5-26) radiographs post frame application. There is a 59% chance of a patient having a difficulty post frame application. The malunion rate was 5%. Persisting pinsite infection post frame removal occurred in 5 patients (6.5%). Drilling of the pinsite sequestrum resolved the infection in four of these patients, giving a deep infection rate of 1.3%. The Ilizarov method has a role to play in the treatment of simple closed Tibial shaft fractures in patients who need to kneel. Patient education is a priority however; the patient must be made aware of the difficulty rate associated with the Ilizarov method when compared to the complication profile of alternative treatments. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  18. The fracture sites of atypical femoral fractures are associated with the weight-bearing lower limb alignment.

    Science.gov (United States)

    Saita, Yoshitomo; Ishijima, Muneaki; Mogami, Atsuhiko; Kubota, Mitsuaki; Baba, Tomonori; Kaketa, Takefumi; Nagao, Masashi; Sakamoto, Yuko; Sakai, Kensuke; Kato, Rui; Nagura, Nana; Miyagawa, Kei; Wada, Tomoki; Liu, Lizu; Obayashi, Osamu; Shitoto, Katsuo; Nozawa, Masahiko; Kajihara, Hajime; Gen, Hogaku; Kaneko, Kazuo

    2014-09-01

    Atypical femoral fractures (AFFs) are stress-related fractures that are speculated to associate with long-term treatment with bisphosphonates for osteoporosis. A history of AFF is a high risk factor for the development of a subsequent AFF in the same location of the contralateral femur, suggesting that a patient's individual anatomical factor(s) are related to the fracture site of AFFs. In this study, we investigated the radiographs of fourteen AFFs (four bilateral fractures among ten patients) treated at six hospitals associated with our university between 2005 and 2010. The fracture site and standing femorotibial angle (FTA), which reflects the mechanical axis of the lower limb, were measured on weight-bearing lower limb radiographs. The fracture site and FTA of patients with typical femoral fractures (TFF) were compared to those of patients with AFFs. The correlations were examined using Spearman's rank correlation coefficients. The fracture locations in the femora were almost the same in the patients with bilateral AFFs. There was a positive correlation between the fracture site and the standing FTA in the patients with AFFs (r=0.82, 95% confidence interval; 0.49 to 0.94), indicating that the larger the standing FTA (varus alignment), the more distal the site of the fracture in the femur. The FTA of the patients with atypical diaphyseal femoral fracture were significantly larger compared to that of those with not only atypical subtrochanteric fractures but also TFFs. In conclusion, the fracture sites of AFFs are associated with the standing lower limb alignment, while those of TFFs are not. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Quality of life after antegrade intramedullary nail fixation of humeral fractures: a survey in a selected cohort of Brazilian patients.

    Science.gov (United States)

    Cocco, Luiz Fernando; Ejnisman, Benno; Belangero, Paulo Santoro; Cohen, Moises; Dos Reis, Fernando Baldy

    2018-01-01

    The treatment of humeral fractures remains controversial. Systematic reviews demonstrate similar results between dynamic compression plating and locked intramedullary nailing in the surgical treatment of these fractures. However, it appears that antegrade intramedullary nailing causes higher residual pain in the shoulder. The proposal of this work is to evaluate through the WORC protocol (Western Ontario Rotator Cuff Index) the consequences in the quality of life of patients submitted to osteosynthesis of the humerus with antegrade locked intramedullary nailing. This work is a cohort retrospective study in addition to the application of a questionnaire for self-rated quality of life with its 05 domains (WORC - Western Ontario Rotator Cuff Index) for patients ( N  = 26) classified in the Trauma Sector of the Department of Orthopedics and Traumatology of the Federal University of São Paulo (DOT/UNIFESP) submitted to Humerus Osteosynthesis with Antegrade Locked Intramedullary Nailing. There was also the inclusion of data related to the time since surgery, age, sex, surgical laterality, dominance among members and work leave, which were not considered in the original protocol. After, the data were statistically assessed to evaluate the association between numerical and categorical variables. The overall WORC score was 82.75 ± 17.00 (Mean ± SD) and was not different considering sex, age and postoperative period. Among the WORC domains, both Work and Sport / Recreation Protocols were the most unfavorable factors in the evaluation of patients. Although not statistically significant, those who had the procedure on the dominant side presented a lower quality of life score than those who had the surgery on the non-dominant side. Although non-significant again, those who were away from work had an overall lower quality of life score than those who were not. The WORC Quality of Life Protocol shows good results for evaluating patients submitted to humerus

  20. ULNAR NEURITIS ASSOCIATED WITH GUN STOCK DEFORMITY FOLLOWING SUPRACONDYLAR FRACTURE OF HUMERUS

    Directory of Open Access Journals (Sweden)

    Sunita Morhan

    2014-04-01

    Full Text Available Background: This case report describes a patient who was referred to physiotherapist from a hand surgeon. Among the fractures around the elbow joint, radial head fracture and fracture of distal end of radius are common among adults. The occurrence of Supracondylar fractures are more commonly seen in children when compared to adults. One of the complications of this fracture is malunion resulting in Gun stock deformity. The main Purpose of this case report is to explore, 1. The complication associated with gunstock deformity 2. Chances of iatrogenic nerve injury after manipulation under anesthesia. 3.Long term supervised rehabilitation approach. Case Description: A 40 years old male patient referred to our Physiotherapy department by a hand surgeon. After the initial evaluation, findings revealed limitation in right elbow movement and tingling and numbness sensation in little and half of ring fingers in his right side. This patient underwent ulnar nerve transposition surgery followed by rehabilitation. His physiotherapy session includes electrotherapeutic agents for pain relief, passive mobilization of elbow and strengthening program for his flexors and extensors of elbow for a period of one year. Outcome: The outcome of the long term rehabilitation approach for a patient with ulnar neuropathy secondary to gunstock deformity after ulnar nerve transposition surgery is good. The patients tingling and numbness decreased and the range of elbow movement improved significantly. Discussion: Most common complications of fracture of distal end of humerus include malunion,ischemic contracture and nerve injuries. The relative incidence of iatrogenic nerve injuries associatedwith this fracture has been reported as being 2%-6%. Nerve injuries after Supracondylar humeral fractures occur primarily due to tenting or entrapment of the nerve on the sharp proximal humeral fragment, while iatrogenic injuries occur either during closed manipulation or percutaneous

  1. Diagnosing displaced four-part fractures of the proximal humerus: a review of observer studies

    DEFF Research Database (Denmark)

    Brorson, Stig; Bagger, Jens; Sylvest, Annette

    2009-01-01

    Displaced four-part fractures comprise 2-10 % of all proximal humeral fractures. The optimal treatment is unclear and randomised trials are needed. The conduct and interpretation of such trials is facilitated by a reproducible fracture classification. We aimed at quantifying observer agreement...... on the classification of displaced four-part fractures according to the Neer system. Published and unpublished data from five observer studies were reviewed. Observers agreed less on displaced four-part fractures than on the overall Neer classification. Mean kappa values for interobserver agreement ranged from 0.......16 to 0.48. Specialists agreed slightly more than fellows and residents. Advanced imaging modalities (CT and 3D CT) seemed to contribute more to classification of displaced four-part patterns than in less complex fracture patterns. Low observer agreement may challenge the clinical approach to displaced...

  2. Triple management of cubitus valgus deformity complicating neglected nonunion of fractures of lateral humeral condyle in children: a case series.

    Science.gov (United States)

    Abed, Yasser; Nour, Khaled; Kandil, Yasser Roshdy; El-Negery, Abed

    2018-02-01

    Long standing nonunion of the lateral humeral condyle (LHC) usually results in elbow pain and instability with progressive cubitus valgus and tardy ulnar neuritis. Surgical treatment of long standing nonunion is still a controversial issue due to the reported complications, such as stiffness, loss of elbow motion, and avascular necrosis of the LHC fragment. In this study, we reported the outcomes of treatment of cubitus valgus deformity in long standing nonunion of the LHC in children treated with combined triple management (fixation of the nonunion site, dome corrective osteotomy, and anterior transposition of ulnar nerve) through a modified para-triceptal approach. We evaluated ten patients with cubitus valgus deformity more than 20 degrees after neglected nonunion of the lateral humeral condyle more than 24 months. Only childern with post-operative follow up more than 24 months were included in this study. All patients were evaluated clinically, radio logically, and by pre- and post-operative functional evaluation using Mayo elbow performance score. For evaluation of ulnar nerve affection, the Akahori's system was used. There were six females and four males with the average age of 7.7 years at operation. The left elbow was affected in six patients and the right elbow was affected in four patients. The average time between fracture of the LHC and operation was 40.3 months with average post-operative follow up of 44.3 months. The average carrying angle of the healthy side was 5.5 degrees and pre-operative carrying angle of the affected side was 33.5 degrees. The average post-operative carrying angle of the affected side was 6.1 degrees. The improvement of the carrying angle at the last follow up was found statistically significant (p  0.05). The mean pre-operative Mayo elbow performance score was poor 55 ± 9.7, four patients had fair score, and six had poor score. The mean post-operative Mayo elbow performance score was excellent 92.5 ± 10, six

  3. Incidence of infection after early intramedullary nailing of open tibial shaft fractures stabilized with pinless external fixators

    Directory of Open Access Journals (Sweden)

    Kulshrestha Vikas

    2008-01-01

    Full Text Available Background: A major drawback of conventional fixator system is the penetration of fixator pins into the medullary canal. The pins create a direct link between the medullary cavity and outer environment, leading to higher infection rates on conversion to intramedullary nailing. This disadvantage is overcome by the AO pinless fixator, in which the trocar points are clamped onto the outer cortex without penetrating it. This study was designed to evaluate the role of AO pinless fixators in primary stabilization of open diaphyseal tibial fractures that received staged treatment because of delayed presentation or poor general condition. We also analyzed the rate of infection on early conversion to intramedullary nail. Materials and Methods: This study is a retrospective review of 30 open diaphyseal fractures of tibia, which were managed with primary stabilization with pinless fixator and early exchange nailing. Outcome was evaluated in terms of fracture union and rate of residual infection. The data were compared with that available in the literature. Results: All the cases were followed up for a period of 2 years. The study includes Gustilo type 1 (n=10, 14 Gustilo type 2 (n=14, and type3 (n=6 cases. 6 cases (20% had clamp site infection, 2 cases (6.7% had deep infection, and in 28 cases (93% the fracture healed and consolidated well. Conclusion: This study has highlighted the valuable role of pinless external fixator in the management of open tibial fractures in terms of safety and ease of application as well as the advantage of early conversion to intramedullary implant without the risk of deep infection.

  4. THE METHOD OF SURGICAL TREATMENT OF HUMERAL EPICONDYLITIS

    Directory of Open Access Journals (Sweden)

    S. B. Korolev

    2011-01-01

    Full Text Available Method of treatment of epicondylitis of humeral bone is descripted. This metod is proposited to use if conservative therapy was not effective. Experience of use this method show excellent results.

  5. Emergency ultrasound in the detection of pediatric long-bone fractures.

    Science.gov (United States)

    Barata, Isabel; Spencer, Robert; Suppiah, Ara; Raio, Christopher; Ward, Mary Frances; Sama, Andrew

    2012-11-01

    .9%-99.2%) and 85.5% (95% CI, 72.8%-93.1%), respectively, and the positive and negative predictive values were 83.7% (95% CI, 68.8%-92.2%) and 96% (95% CI, 84.9%-99.3%), respectively. Overall, ultrasound detected 100.0% of diaphyseal fractures and 27 (93.1%) of 29 end-of-bone or near-joint fractures.Radiography revealed 6 displacements that met the published criteria for reduction, all of which were also revealed by ultrasound. The overall sensitivity and specificity for ultrasound identifying the need for reduction were 100.0% (95% CI, 51.7%-100.0%) and 97.3% (95% CI, 84.2%-99.9%), respectively, and positive and negative predictive values were 85.7% (95% CI, 42.0%-99.2%) and 100.0% (95% CI, 88.0%-100.0%), respectively. Emergency department physician-performed focused ultrasound was more accurate in detecting diaphyseal fractures than in detecting fractures in the metaphysis and/or epiphysis. The high sensitivity and specificity of ultrasound in the detection of long-bone fractures and the need for reduction support the use of ultrasound in the evaluation of suspected long-bone fractures in children.

  6. Economic aspects of complicated osteoporosis: The cost of treatment in the first year after fracture

    OpenAIRE

    O. V. Dobrovolskaya; N. V. Toroptsova; O. M. Lesnyak

    2016-01-01

    Objective: to estimate the cost of treatment in patients with complicated osteoporosis (OP) in the first year after fracture under the conditions of the Moscow municipal healthcare system.Patients and methods. The investigation enrolled 196 women (mean age, 65.8±9.1 years) who had sustained fractures at five major osteoporotic sites (proximal hip (PH), distal forearm (DF), surgical humeral neck, vertebral column, and medial and/or lateral ankle). A unified questionnaire that included data on ...

  7. A PROSPECTIVE STUDY OF SUPRACONDYLAR FRACTURES OF THE HUMERUS IN CHILDREN TREATED BY CLOSED REDUCTION

    Directory of Open Access Journals (Sweden)

    Ch. Imobi

    2015-08-01

    Full Text Available There is no universal agreement regarding the management of displaced supracondylar fracture of the humerous in children. According to some orthopaedic surgeon almost all supracondylar humeral fractures should be treated operatively by reduction and pinning. While according to others closed reduction and pinning should be used for Gartland type II and some type III fractures. We present 50 cases of displaced supracondylar fracture treated by closed manipulative reduction under G.A. and immobilization with a posterior plaster of paris slab and collar and cuff. OBJECTIVE : T o assess the functional results of the injured elbow and to study the incidence of change in the carrying angle of the elbow. MATERIALS AND METHODS: This prospective study was conducted in 50 patients with extension type of displaced supracondylar fractures of humerus in children (Gartland type II and type III treated by closed manipulative reduction and immobilization in flexion of the elbow with a posterior plaster of paris slab and collar and cuff. Patients were followed up for 6 months. Flexion type of supracondylar fracture and those fractures which are absolutely indicated for operative intervention, Viz an open fracture and severe vascular compromise were excluded from the study. The range of movement and carrying angle was measured with the help of a Goniometer and Flynn criteria were used for functional assessment. RESULTS: At the end of follow up period, the end results were graded as excellent in 40%, good in 42%, fair in 12% and poor in 6%. A satisfactory result was therefore obtained in 94% and unsatisfactory result in 6% of the 50 patients who were followed and evaluated. CONCLUSION: This closed method of treatment for all practical proposes produces least complications, shorter hospital stay, can be expected to yield reproducible consistent satisfactory results not surpassed by any other method of treatment.

  8. Elastic robust intramedullary nailing for forearm fracture in children

    Directory of Open Access Journals (Sweden)

    Wasem, Jürgen

    2006-01-01

    Full Text Available Background: Forearm fractures are the most common fractures in children (23% of all fractures. Basically there are two treatment options available for diaphyseal forearm fractures in children: closed reduction with cast immobilisation (conservative therapy and the elastic stable intramedullary nailing (ESIN. Treatment decision is influenced by the doctor's estimation of fracture instability. Stable fractures can be treated conservatively whereas instable forearm shaft fractures can be treated according the following three treatment strategies: 1. conservative therapy in an outpatient setting 2. conservative therapy in the operating room in attendance to change to ESIN in case that no stabilisation can be achieved with cast immobilisation 3. immediate treatment with ESIN in the operating room. Objectives: Aim of this Health Technology Assessment (HTA report is to assess and report the published evidence concerning effectiveness and cost-effectiveness of ESIN as a treatment option for diaphyseal forearm fractures in children and to identify future research need. Important parameters for the assessment of effectiveness are objective parameters (axis deviation, losses of motion, and numbers of reductions in case of redislocations and subjective parameters (pain or impairment in quality of life. Furthermore, a health economic evaluation shall be done which refers to the costs of the different therapy strategies. Methods: An extensive, systematic literature search in medical, economic, and HTA literature databases was performed. Relevant data were extracted and synthesised. Results: Three cohort studies and seven case series have been identified. Controlled clinical studies, systematic reviews and/or HTA reports that gave evidence to answer the own study question have not been found. The identified studies partly differed in respect of defined indication for ESIN, study population and treatment strategies. For that reason comparability of results was

  9. Management of neglected lateral condyle fractures of humerus in children: A retrospective study

    Directory of Open Access Journals (Sweden)

    Anil Agarwal

    2012-01-01

    Full Text Available Background: Late presentation of humeral lateral condylar fracture in children is a surgical dilemma. Osteosynthesis of the fracture fragment or correction of elbow deformity with osteotomies and ulnar nerve transposition or sometimes both procedures combined is a controversial topic. We retrospectively evaluated open reduction and fixation cases in late presentation of lateral humeral condyle fracture in pediatric cases with regards to union and functional results. Materials and Methods: Twenty two pediatric (≤12 years patients with fractures of lateral condyle presenting 4 weeks or more post injury between the study period of 2006 and 2010 were included. Multiple K-wires / with or without screws along with bone grafting were used. At final evaluation, union (radiologically and elbow function (Liverpool Elbow Score, LES was assessed. Results: There were 19 boys and 3 girls. Followup averaged 33 months. Pain (n=9, swelling (n=6, restriction of elbow motion (n=6, prominence of lateral condylar region (n=4, valgus deformity (n=4 were the main presenting symptoms. Ulnar nerve function was normal in all patients. There were nine Milch type I and 13 type II fractures. Union occurred in 20 cases. One case had malunion and in another case there was resorption of condyle following postoperative infection and avascular necrosis. Prominent lateral condyles (4/12, fish tail appearance (n=7, premature epiphyseal closure (n=2 were other observations. LES averaged 8.12 (range, 6.66-9.54 at final followup. Conclusions: There is high rate of union and satisfactory elbow function in late presenting lateral condyle fractures in children following osteosynthesis attempt. Our study showed poor correlation between patient′s age, duration of late presentation or Milch type I or II and final elbow function as determined by LES.

  10. Dorgan's lateral cross-wiring of supracondylar fractures of the humerus in children: A retrospective review.

    LENUS (Irish Health Repository)

    Queally, Joseph M

    2010-06-01

    The currently accepted treatment for displaced supracondylar humeral fractures in children is closed reduction and fixation with percutaneous Kirschner wires. The purpose of this study was to retrospectively review a novel cross-wiring technique where the cross-wire configuration is achieved solely from the lateral side, thereby reducing the risk of ulnar nerve injury.

  11. Functional results following fractures of the proximal humerus. A controlled clinical study comparing two periods of immobilization

    DEFF Research Database (Denmark)

    Kristiansen, B; Angermann, P; Larsen, T K

    1989-01-01

    In order to compare 1 and 3 weeks of immobilization following proximal humeral fractures a prospective controlled trial was performed in 85 patients. Clinical follow-up according to the Neer assessment system was done after 1, 3, 6, 12, and 24 months. One week of immobilization resulted in a better...

  12. Management of simple (types A and B) closed tibial shaft fractures using percutaneous lag-screw fixation and Ilizarov external fixation in adults.

    Science.gov (United States)

    El-Sayed, Mohamed; Atef, Ashraf

    2012-10-01

    Although intramedullary fixation of closed simple (type A or B) diaphyseal tibial fractures in adults is well tolerated by patients, providing lower morbidity rates and better mobility, it is associated with some complications. This study evaluated the results of managing these fractures using percutaneous minimal internal fixation using one or more lag screws, and Ilizarov external fixation. This method was tested to evaluate its efficacy in immediate weight bearing, fracture healing and prevention of any post-immobilisation stiffness of the ankle and knee joints. This randomised blinded study was performed at a referral, academically supervised, level III trauma centre. Three hundred and twenty-four of the initial 351 patients completed this study and were followed up for a minimum of 12 (12-88) months. Patient ages ranged from 20 to 51 years, with a mean of 39 years. Ankle and knee movements and full weight bearing were encouraged immediately postoperatively. Solid union was assessed clinically and radiographically. Active and passive ankle and knee ranges of motion were measured and compared with the normal side using the Wilcoxon signed rank test for matched pairs. Subjective Olerud and Molander Ankle Score was used to detect any ankle joint symptoms at the final follow-up. No patient showed delayed or nonunion. All fractures healed within 95-129 days. Based on final clinical and radiographic outcomes, this technique proves to be adequate for managing simple diaphyseal tibial fractures. On the other hand, it is relatively expensive, technically demanding, necessitates exposure to radiation and patients are expected to be frame friendly.

  13. The supinated mediolateral radiograph for detection of humeral head osteochondrosis in the dog

    International Nuclear Information System (INIS)

    Callahan, T.F.; Ackerman, N.

    1985-01-01

    Mediolateral and supinated mediolateral radiographs of the shoulder joint were compared in 19 dogs. Twenty shoulders, representing 15 dogs (5 had bilateral lesions), had osteochondrosis of the humeral head. The flattened humeral head and subchondral defect were detectable in both views in all affected shoulders. The lesions were slightly more easily detected in the supinated view. The supinated view more consistently demonstrated the presence of a calcified cartilage flap and therefore, could be useful in determining a course of therapy. In four dogs (8 shoulders) without osteochondrosis and six normal shoulders from affected dogs, there were no instances in which a shoulder appeared normal on one view, but demonstrated a lesion on the other. The supinated view should be obtained in addition to the mediolateral view in dogs with osteochondrosis of the humeral head

  14. Do stress fractures induce hypertrophy of the grafted fibula? A report of three cases received free vascularized fibular graft treatment for tibial defects.

    Science.gov (United States)

    Qi, Yong; Sun, Hong-Tao; Fan, Yue-Guang; Li, Fei-Meng; Lin, Zhou-Sheng

    2016-06-01

    The presence of large segmental defects of the diaphyseal bone is challenging for orthopedic surgeons. Free vascularized fibular grafting (FVFG) is considered to be a reliable reconstructive procedure. Stress fractures are a common complication following this surgery, and hypertrophy is the main physiological change of the grafted fibula. The exact mechanism of hypertrophy is not completely known. To the best of our knowledge, no studies have examined the possible relationship between stress fractures and hypertrophy. We herein report three cases of patients underwent FVFG. Two of them developed stress fractures and significant hypertrophy, while the remaining patient developed neither stress fractures nor significant hypertrophy. This phenomenon indicates that a relationship may exist between stress fractures and hypertrophy of the grafted fibula, specifically, that the presence of a stress fracture may initiate the process of hypertrophy.

  15. Reliability and validity in measurement of true humeral retroversion by a three-dimensional cylinder fitting method.

    Science.gov (United States)

    Saka, Masayuki; Yamauchi, Hiroki; Hoshi, Kenji; Yoshioka, Toru; Hamada, Hidetoshi; Gamada, Kazuyoshi

    2015-05-01

    Humeral retroversion is defined as the orientation of the humeral head relative to the distal humerus. Because none of the previous methods used to measure humeral retroversion strictly follow this definition, values obtained by these techniques vary and may be biased by morphologic variations of the humerus. The purpose of this study was 2-fold: to validate a method to define the axis of the distal humerus with a virtual cylinder and to establish the reliability of 3-dimensional (3D) measurement of humeral retroversion by this cylinder fitting method. Humeral retroversion in 14 baseball players (28 humeri) was measured by the 3D cylinder fitting method. The root mean square error was calculated to compare values obtained by a single tester and by 2 different testers using the embedded coordinate system. To establish the reliability, intraclass correlation coefficient (ICC) and precision (standard error of measurement [SEM]) were calculated. The root mean square errors for the humeral coordinate system were reliability and precision of the 3D measurement of retroversion yielded an intratester ICC of 0.99 (SEM, 1.0°) and intertester ICC of 0.96 (SEM, 2.8°). The error in measurements obtained by a distal humerus cylinder fitting method was small enough not to affect retroversion measurement. The 3D measurement of retroversion by this method provides excellent intratester and intertester reliability. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  16. Closed Versus Open Supracondylar Fractures of the Humerus in Children: A Comparison of Clinical and Radiographic Presentation and Results.

    Science.gov (United States)

    Lewine, Eliza; Kim, Jaehon M; Miller, Patricia E; Waters, Peter M; Mahan, Susan T; Snyder, Brian; Hedequist, Daniel; Bae, Donald S

    2018-02-01

    The purpose of this investigation was to compare the presentation and postoperative results of children treated for open and closed, completely displaced type III supracondylar humerus fractures (SCFs). Thirty patients with open and 66 patients with closed, completely displaced type III SCFs were evaluated. Open fractures underwent irrigation and debridement, and all patients were treated by open or closed reduction and pin fixation. Medical records were reviewed to obtain demographic information as well as preoperative and postoperative clinical data regarding mechanism of injury, neurovascular status, associated injuries, postoperative range of motion, infections, and pain. Radiographs were evaluated to quantify displacement, Baumann's angle, humeral capitellar angle, position of the anterior humeral line, and adequacy of reduction. Outcomes were assessed using Flynn criteria. Mean clinical follow-up for the open and closed fracture groups was 8.9 and 5.7 months, respectively. Both groups were similar with respect to age, sex distribution, weight and body mass index, laterality of involvement, and mechanism of injury. At presentation, 35% of closed SCFs and 23% of open SCFs presented with abnormal neurovascular status. There was a higher prevalence of diminished/absent pulses or distal limb ischemia in patients with open injuries (27%) compared with closed fractures (18%). Conversely, severely displaced closed fractures were more commonly associated with nerve injury/palsy at presentation (35%) than those with open fractures (23%). Spontaneous nerve recovery was seen in 87% within 3 to 6 months. Postoperative loss of reduction and malunion were more common in the closed fracture group. However, 84% of patients achieved good-to-excellent results by Flynn criteria, with no appreciable difference based upon open versus closed fractures. With timely wound and fracture treatment, the clinical and radiographic results of children treated for open SCFs is similar to

  17. A study of repair cartilage from osteochondrotic humeral condyles of swine: preliminary report.

    OpenAIRE

    Nakano, T; Aherne, F X

    1992-01-01

    A total of 16 animals, including 12 lame and four normal boars, were used. All lame boars had severe osteochondrotic humeral condyles in which repair cartilage tissues originating from subchondral bone were observed. Quantitative chemical studies of repair cartilage and normal cartilage were carried out using humeral condyles from four selected animals (two lame and two normal boars, respectively). The repair cartilage contained a higher concentration of collagen and lower concentration of pr...

  18. Magnesium-Based Absorbable Metal Screws for Intra-Articular Fracture Fixation

    Directory of Open Access Journals (Sweden)

    Roland Biber

    2016-01-01

    Full Text Available MAGNEZIX® (Syntellix AG, Hanover, Germany is a biodegradable magnesium-based alloy (MgYREZr which is currently used to manufacture bioabsorbable compression screws. To date, there are very few studies reporting on a limited number of elective foot surgeries using this innovative implant. This case report describes the application of this screw for osteochondral fracture fixation at the humeral capitulum next to a loose radial head prosthesis, which was revised at the same time. The clinical course was uneventful. Degradation of the magnesium alloy did not interfere with fracture healing. Showing an excellent clinical result and free range-of-motion, the contour of the implant was still visible in a one-year follow-up.

  19. Clinical outcome and complications using a polyaxial locking plate in the treatment of displaced proximal humerus fractures. A reliable system?

    Science.gov (United States)

    Königshausen, M; Kübler, L; Godry, H; Citak, M; Schildhauer, T A; Seybold, D

    2012-02-01

    The surgical treatment of displaced proximal humeral fractures (ORIF) is a perpetual challenge to the surgeon. For this reason, the principle of polyaxiality was developed to provide an improved primary stability of the fracture through better anchorage of the screws, especially in osteoporotic bone. The aim of this study was to present clinical results with the polyaxial locking plate in the operative treatment of proximal humerus fractures in order to determine whether the technique of polyaxiality leads to better functional outcome and lower complication rates in comparison to monoaxial plates in the literature. Seventy-three patients with displaced proximal humeral fractures were treated surgically with the polyaxial locking Suture Plate™ (Arthrex(®)) between 03/2007 and 06/2009. Fifty-two of the patients (mean age, 69.9 ± 12.1) were included in a radiographical and clinical examination using the Constant score (CS) and the Disabilities of the Arm, Shoulder and Hand score (DASH). The follow-up examinations were on average 13.9 ± 4.5 months (10-27 months) after surgical treatment. The mean CS of the patients was 66.0 ± 13.7 points, the age- and gender-related CS was 90.9% ± 20.0% and the mean DASH score was 23.8 ± 19.8 points for the injured side. The patients with a nearly anatomical reduction of their fracture (n = 13) reached a significantly higher CS (75.1 ± 8.5; p = 0.004) and DASH-score (13.6 ± 11.6; p = 0.043) and none of these patients had a complication. The complications were identified in 12 (23.1%) cases, 5 of which involved loss of reduction. All of these 5 cases were lacking of initial medial column support and 4 of which were type C2.3 AO-Classification. The data show that the combination of angular stability with the possibility of variable polyaxial screw direction is a good concept for reduction and fixation of displaced proximal humeral fractures, but anatomical reduction and medial support remain important preconditions for a good

  20. Endogenous PTH deficiency impairs fracture healing and impedes the fracture-healing efficacy of exogenous PTH(1-34.

    Directory of Open Access Journals (Sweden)

    Yongxin Ren

    Full Text Available Although the capacity of exogenous PTH1-34 to enhance the rate of bone repair is well established in animal models, our understanding of the mechanism(s whereby PTH induces an anabolic response during skeletal repair remains limited. Furthermore it is unknown whether endogenous PTH is required for fracture healing and how the absence of endogenous PTH would influence the fracture-healing capacity of exogenous PTH.Closed mid-diaphyseal femur fractures were created and stabilized with an intramedullary pin in 8-week-old wild-type and Pth null (Pth(-/- mice. Mice received daily injections of vehicle or of PTH1-34 (80 µg/kg for 1-4 weeks post-fracture, and callus tissue properties were analyzed at 1, 2 and 4 weeks post-fracture. Cartilaginous callus areas were reduced at 1 week post-fracture, but were increased at 2 weeks post-fracture in vehicle-treated and PTH-treated Pth(-/- mice compared to vehicle-treated and PTH-treated wild-type mice respectively. The mineralized callus areas, bony callus areas, osteoblast number and activity, osteoclast number and surface in callus tissues were all reduced in vehicle-treated and PTH-treated Pth(-/- mice compared to vehicle-treated and PTH-treated wild-type mice, but were increased in PTH-treated wild-type and Pth(-/- mice compared to vehicle-treated wild-type and Pth(-/- mice.Absence of endogenous PTH1-84 impedes bone fracture healing. Exogenous PTH1-34 can act in the absence of endogenous PTH but callus formation, including accelerated endochondral bone formation and callus remodeling as well as mechanical strength of the bone are greater when endogenous PTH is present. Results of this study suggest a complementary role for endogenous PTH1-84 and exogenous PTH1-34 in accelerating fracture healing.

  1. Endogenous PTH deficiency impairs fracture healing and impedes the fracture-healing efficacy of exogenous PTH(1-34).

    Science.gov (United States)

    Ren, Yongxin; Liu, Bo; Feng, Yuxu; Shu, Lei; Cao, Xiaojian; Karaplis, Andrew; Goltzman, David; Miao, Dengshun

    2011-01-01

    Although the capacity of exogenous PTH1-34 to enhance the rate of bone repair is well established in animal models, our understanding of the mechanism(s) whereby PTH induces an anabolic response during skeletal repair remains limited. Furthermore it is unknown whether endogenous PTH is required for fracture healing and how the absence of endogenous PTH would influence the fracture-healing capacity of exogenous PTH. Closed mid-diaphyseal femur fractures were created and stabilized with an intramedullary pin in 8-week-old wild-type and Pth null (Pth(-/-)) mice. Mice received daily injections of vehicle or of PTH1-34 (80 µg/kg) for 1-4 weeks post-fracture, and callus tissue properties were analyzed at 1, 2 and 4 weeks post-fracture. Cartilaginous callus areas were reduced at 1 week post-fracture, but were increased at 2 weeks post-fracture in vehicle-treated and PTH-treated Pth(-/-) mice compared to vehicle-treated and PTH-treated wild-type mice respectively. The mineralized callus areas, bony callus areas, osteoblast number and activity, osteoclast number and surface in callus tissues were all reduced in vehicle-treated and PTH-treated Pth(-/-) mice compared to vehicle-treated and PTH-treated wild-type mice, but were increased in PTH-treated wild-type and Pth(-/-) mice compared to vehicle-treated wild-type and Pth(-/-) mice. Absence of endogenous PTH1-84 impedes bone fracture healing. Exogenous PTH1-34 can act in the absence of endogenous PTH but callus formation, including accelerated endochondral bone formation and callus remodeling as well as mechanical strength of the bone are greater when endogenous PTH is present. Results of this study suggest a complementary role for endogenous PTH1-84 and exogenous PTH1-34 in accelerating fracture healing.

  2. Neglected distal humeral epiphyseal injury - Two Case Reports ...

    African Journals Online (AJOL)

    We present two cases of neglected distal humeral epiphyseal injury in children that resulted in cubitus varus deformity in one case. Full range of movements was achieved in both cases after proper management. Keywords: Neglected epiphyseal injury; Cubitus varus; Diagnosis; Treatment Internet Journal of Medical Update ...

  3. Economic aspects of complicated osteoporosis: The cost of treatment in the first year after fracture

    Directory of Open Access Journals (Sweden)

    O. V. Dobrovolskaya

    2016-01-01

    Full Text Available Objective: to estimate the cost of treatment in patients with complicated osteoporosis (OP in the first year after fracture under the conditions of the Moscow municipal healthcare system.Patients and methods. The investigation enrolled 196 women (mean age, 65.8±9.1 years who had sustained fractures at five major osteoporotic sites (proximal hip (PH, distal forearm (DF, surgical humeral neck, vertebral column, and medial and/or lateral ankle. A unified questionnaire that included data on inpatient and outpatient treatment, patients' personal costs, and social benefits, as well as tariffs on services of the Moscow City Fund of Obligatory Health Insurance was used to estimate the cost of treatment for complicated OP during one year after fracture.Results. The direct cost of treatment for PH fracture amounted to 101,243 rubles and was significantly higher (p < 0.01 than that for fractures at other sites: DF (22,080 rubles; humeral neck (39,855 rubles, vertebral column (51,167 rubles, and ankle (43,345 rubles. The average cost of treatment in terms of indirect costs of treatment for complicated OP during a year was as high as 61,151 rubles. In the overall cost structure for the disease, hospital costs accounted for 44%; social benefits were 12% and the cost of antiosteoporotic drugs was only 7%, which was associated with the fact that the latter were rarely prescribed by primary healthcare physicians.Conclusion. Costs of treatment in patients with complicated OP in Moscow were estimated in relation to the site of low-energy fracture. The disease was shown to cause considerable economic losses regardless of the site of osteoporotic fracture; however, the cost of antiosteoporotic drugs has an insignificant share in the overall cost structure for treatment. At the same time, secondary prevention of OP requires that combination antiosteoporotic therapy should be performed in all patients who have sustained low-energy fracture.

  4. Dominant-limb range-of-motion and humeral-retrotorsion adaptation in collegiate baseball and softball position players.

    Science.gov (United States)

    Hibberd, Elizabeth E; Oyama, Sakiko; Tatman, Justin; Myers, Joseph B

    2014-01-01

    Biomechanically, the motions used by baseball and softball pitchers differ greatly; however, the throwing motions of position players in both sports are strikingly similar. Although the adaptations to the dominant limb from overhead throwing have been well documented in baseball athletes, these adaptations have not been clearly identified in softball players. This information is important in order to develop and implement injury-prevention programs specific to decreasing the risk of upper extremity injury in softball athletes. To compare range-of-motion and humeral-retrotorsion characteristics of collegiate baseball and softball position players and of baseball and softball players to sex-matched controls. Cross-sectional study. Research laboratories and athletic training rooms at the University of North Carolina at Chapel Hill. Fifty-three collegiate baseball players, 35 collegiate softball players, 25 male controls (nonoverhead athletes), and 19 female controls (nonoverhead athletes). Range of motion and humeral retrotorsion were measured using a digital inclinometer and diagnostic ultrasound. Glenohumeral internal-rotation deficit, external-rotation gain, total glenohumeral range of motion, and humeral retrotorsion. Baseball players had greater glenohumeral internal-rotation deficit, total-range-of-motion, and humeral-retrotorsion difference than softball players and male controls. There were no differences between glenohumeral internal-rotation deficit, total-range-of-motion, and humeral-retrotorsion difference in softball players and female controls. Few differences were evident between softball players and female control participants, although range-of-motion and humeral-retrotorsion adaptations were significantly different than baseball players. The throwing motions are similar between softball and baseball, but the athletes adapt to the demands of the sport differently; thus, stretching/strengthening programs designed for baseball may not be the most

  5. Percutaneous Kirschner wire (K-wire) fixation for humerus shaft ...

    African Journals Online (AJOL)

    Background: Fractures of the humeral shaft are uncommon, representing less than 10 percent of all fractures in children. Humeral shaft fractures in children can be treated by immobilisation alone. A small number of fractures are unable to be reduced adequately or maintained in adequate alignment, and these should be ...

  6. Outcome of limb fracture repair in rabbits: 139 cases (2007-2015).

    Science.gov (United States)

    Sasai, Hiroshi; Fujita, Daisuke; Seto, Eiko; Denda, Yuki; Imai, Yutaro; Okamoto, Kanako; Okamura, Kensaku; Furuya, Masaru; Tani, Hiroyuki; Sasai, Kazumi

    2018-02-15

    OBJECTIVE To evaluate outcome of limb fracture repair in rabbits. DESIGN Retrospective case series. ANIMALS 139 client-owned rabbits with limb fractures treated between 2007 and 2015. PROCEDURES Medical records were reviewed for information on fracture location, fracture treatment, and time to fracture healing. RESULTS 25 rabbits had fractures involving the distal aspects of the limbs (ie, metacarpal or metatarsal bones, phalanges, and calcaneus or talus). Fractures were treated in 23 of these 25 rabbits (external coaptation, n = 17; external skeletal fixation, 4; and intramedullary pinning, 2) and healed in all 23, with a median healing time of 28 days (range, 20 to 45 days). One hundred ten rabbits had long bone fractures, and fractures were treated in 100 of the 110 (external skeletal fixation, n = 89; bone plating, 1; intramedullary pinning, 3; and external coaptation, 7). The percentage of fractures that healed was significantly lower for open (14/18) than for closed (26/26) tibial fractures and was significantly lower for femoral (19/26) and treated humeral (4/6) fractures than for radial (23/24) or closed tibial (26/26) fractures. Micro-CT was used to assess fracture realignment during external skeletal fixator application and to evaluate fracture healing. CONCLUSIONS AND CLINICAL RELEVANCE The prognosis for rabbits with limb fractures was good, with fractures healing in most rabbits following fracture repair (109/123). Micro-CT was useful in assessing fracture realignment and evaluating fracture healing.

  7. Monoaxial versus polyaxial locking systems: a biomechanical analysis of different locking systems for the fixation of proximal humeral fractures.

    Science.gov (United States)

    Zettl, Ralph; Müller, Thorben; Topp, Tobias; Lewan, Ulrike; Krüger, Antonio; Kühne, Christian; Ruchholtz, Steffen

    2011-08-01

    The development of locking plate systems has led to polyaxial screws and new plate designs. This study compares monoaxial head locking screws (PHILOS© by Synthes) and a new generation of polyaxial locking screws (NCB-LE© by Zimmer) with respect to biomechanical stability. On nine pairs of randomised formalin fixed humerus specimens, standardised osteotomies and osteosyntheses with nine monoaxial (group A) und nine polyaxial (group B) plate/screw systems were performed. A material testing machine by Instron (M-10 14961-DE) was used for cyclic stress tests and crash tests until defined breakup criteria as endpoints were reached. After axial cyclic stress 200 times at 90 N, plastic deformation was 1.02 mm in group A and 1.25 mm in group B. After the next cycle using 180 N the additional deformation averaged 0.23 mm in group A and 0.39 mm in group B. The deformation using 450 N was 0.72 mm in group A compared to 0.92 mm in group B. The final full power test resulted in a deformation average of 0.49 mm in group A and 0.63 mm in group B after 2,000 cycles using 450 N. When reaching the breakup criteria the plastic deformation of the NCB plate was 9.04 mm on average. The PHILOS plate was similarly deformed by 9.00 mm. As a result of the crash test, in group A the screws pulled out of the humeral head four times whereas the shaft broke one time and another time the implant was ripped out. The gap was closed four times. In group B, there were three cases of screw cut-through, four shaft fractures/screw avulsions from the shaft and two cases of gap closure. The two systems resist the cyclic duration tests and the increasing force tests in a similar manner. The considerable clinical benefits of the polyaxial system are enhanced by equal biomechanical performance.

  8. Blunt traumatic axillary artery truncation, in the absence of associated fracture.

    Science.gov (United States)

    Bokser, Emily; Caputo, William; Hahn, Barry; Greenstein, Josh

    2018-02-01

    Axillary artery injuries can be associated with both proximal humeral fractures (Naouli et al., 2016; Ng et al., 2016) [1,2] as well as shoulder dislocations (Leclerc et al., 2017; Karnes et al., 2016) [3,4]. We report a rare case of an isolated axillary artery truncation following blunt trauma without any associated fracture or dislocation. A 58-year-old male presented to the emergency department for evaluation after falling on his outstretched right arm. The patient was found to have an absent right radial pulse with decreased sensation to the right arm. Point of care ultrasound showed findings suspicious for traumatic axillary artery injury, and X-rays did not demonstrate any fracture. Computed tomography with angiography confirmed axillary artery truncation with active extravasation. The patient underwent successful vascular repair with an axillary artery bypass. Although extremity injuries are common in emergency departments, emergency physicians need to recognize the risk for vascular injuries, even without associated fracture or dislocation. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Articular reconstruction of the humeral head with autogenous allograft in the treatment of the osteonecrosis

    Directory of Open Access Journals (Sweden)

    Alberto Naoki Miyazaki

    Full Text Available ABSTRACT The authors describe a surgical biological reconstruction of the humeral head with frozen autogenous allograft technique for the treatment of young patients with focal osteonecrosis of the humeral head. This represents a possible alternative, maybe even definitive for some patients, when compared to hemiarthroplasty or total shoulder arthroplasty. The technique consists of the fixation of a frozen autogenous allograft with previously-molded articular cartilage from the humeral head, after cleansing the osteonecrotic focus. Five patients under 50 years of age were treated, with three very satisfactory results, one patient was lost to follow-up, and one patient had an unsatisfactory result (converted to hemiarthroplasty. The study describes the technique in detail and the three cases with a longer follow-up time.

  10. Bilateral atypical insufficiency fractures of the proximal tibia and a unilateral distal femoral fracture associated with long-term intravenous bisphosphonate therapy: a case report

    Directory of Open Access Journals (Sweden)

    Imbuldeniya Arjuna

    2012-02-01

    Full Text Available Abstract Introduction Atypical insufficiency fractures of the femur in patients on long-term bisphosphonate therapy have been well described in recent literature. The majority of cases are associated with minimal or no trauma and occur in the subtrochanteric or diaphyseal region. Case presentation We describe the case of a 76-year-old British Caucasian woman who presented initially to an emergency department and then to her primary care physician with a long-standing history of bilateral knee pain after minor trauma. Plain radiographs showed subtle linear areas of sclerosis bilaterally in her proximal tibiae. Magnetic resonance imaging confirmed the presence of insufficiency fractures in these areas along with her left distal femur. There are very few reports of atypical insufficiency fractures involving the tibia in patients on long-term bisphosphonate therapy and this appears to be the only documented bilateral case involving the metaphyseal regions of the proximal tibia and distal femur. Conclusion In addition to existing literature describing atypical fractures in the proximal femur and femoral shaft, there is a need for increased awareness that these fractures can also occur in other weight-bearing areas of the skeleton. All clinicians involved in the care of patients taking long-term bisphosphonates need to be aware of the growing association between new onset lower limb pain and atypical insufficiency fractures.

  11. Progressive diaphyseal dysplasia (Engelmann's disease) - Report of a case -

    International Nuclear Information System (INIS)

    Soh, M. H.; Rhee, S. J.; Won, J. J.

    1981-01-01

    Progressive diaphyseal dysplasia is a rare condition and radiographic finding provides conclusive proof. We have experienced a sporadic case of progressive disphyseal dysplasia (Engelmann's disease) of 8 year-old-Korean girl, confirmed by radiographic skeletal survey and biopsy. This patient was admitted to the Jeonbug National University Hospital because of painful swelling of the distal part of the right femur after trauma and intermittent pain in her lower legs with a peculiar wadding gait for 2 years. On a physical examination, the patient appeared thin and slender. The skeletal musculature was poorly developed and the upper and lower extremities were weak. She walked with a peculiar wadding gait. The height was normal. No joint abnormality was noted and the mental state was alert. The child was the product of a normal gestation and delivery. Radiographic studies of the skeleton showed a generalized and symmetrical distribution of the bone characterized by cortical thickening, fusiform enlargement, and a narrowed medullary cavity in the diaphyseal of long bones while the epiphyses and metaphyses was not involved. Abrupt demarcation of the lesion with loss of normal trabecular pattern was note. Elongation of the extremities relative to the size of the child was present. The above radiographic findings showed involvement of all the long tubular bones such as the ulna, radius, tibia, fibula, femur and humerus. A sight sclerosis of the base of her skull was present, but the calvarium was not involved. The hands, feet, pelvis, spine, clavicle, rib, scapula and mandible were not affected. There was no specific laboratory finding except for the slightly elevated ESR. Histological examination of the bone biopsies from the femur revealed thickening of periosteum and proliferation of the walls of the small arterioles with reduction in the size of the lumen. The bony cortex showed essentially normal bone with the increased osteoblastic and osteoclastic activity

  12. Does Humeral Component Lateralization in Reverse Shoulder Arthroplasty Affect Rotator Cuff Torque? Evaluation in a Cadaver Model.

    Science.gov (United States)

    Chan, Kevin; Langohr, G Daniel G; Mahaffy, Matthew; Johnson, James A; Athwal, George S

    2017-10-01

    Humeral component lateralization in reverse total shoulder arthroplasty (RTSA) may improve the biomechanical advantage of the rotator cuff, which could improve the torque generated by the rotator cuff and increase internal and external rotation of the shoulder. The purpose of this in vitro biomechanical study was to evaluate the effect of humeral component lateralization (or lateral offset) on the torque of the anterior and posterior rotator cuff. Eight fresh-frozen cadaveric shoulders from eight separate donors (74 ± 8 years; six males, two females) were tested using an in vitro simulator. All shoulders were prescreened for soft tissue deficit and/or deformity before testing. A custom RTSA prosthesis was implanted that allowed five levels of humeral component lateralization (15, 20, 25, 30, 35 mm), which avoided restrictions imposed by commercially available designs. The torques exerted by the anterior and posterior rotator cuff were measured three times and then averaged for varying humeral lateralization, abduction angle (0°, 45°, 90°), and internal and external rotation (-60°, -30°, 0°, 30°, 60°). A three-way repeated measures ANOVA (abduction angle, humeral lateralization, internal rotation and external rotation angles) with a significance level of α = 0.05 was used for statistical analysis. Humeral lateralization only affected posterior rotator cuff torque at 0° abduction, where increasing humeral lateralization from 15 to 35 mm at 60° internal rotation decreased external rotation torque by 1.6 ± 0.4 Nm (95% CI, -0.07 -1.56 Nm; p = 0.06) from 4.0 ± 0.3 Nm to 2.4 ± 0.6 Nm, respectively, but at 60° external rotation increased external rotation torque by 2.2 ± 0.5 Nm (95% CI, -4.2 to -0.2 Nm; p = 0.029) from 6.2 ± 0.5 Nm to 8.3 ± 0.5 Nm, respectively. Anterior cuff torque was affected by humeral lateralization in more arm positions than the posterior cuff, where increasing humeral lateralization from 15 to 35 mm when at 60° internal rotation

  13. Fixação esquelética externa tipo Ia (unilateral-uniplanar para osteossíntese diafisária de úmero em pombos domésticos (Columba livia Type Ia (unilateral-uniplanar external Skeletal fixation for treatment of humeral diaphysis fracture in domestic pigeons (Columba livia

    Directory of Open Access Journals (Sweden)

    Alessandro Moraes Leotte

    2004-12-01

    Full Text Available Das várias patologias que podem acometer as aves, são mais freqüentes as fraturas de ossos longos das asas e dos membros pélvicos. Este experimento teve como objetivo observar, por meio de exames clínicos, histológicos e radiográficos, a resposta cicatricial óssea ao uso do fixador externo tipo Ia (unilateral-uniplanar na redução aberta de fratura diafisária, de úmero em pombos domésticos (Columba livia. Foram estudados 14 pombos com peso variando entre 290 e 420 gramas. A fratura foi realizada na diáfise do úmero direito e, logo após, estabilizada com aparelho de fixação externa tipo Ia, utilizando-se, como barra de fixação, o acrílico autopolimerizável. O tempo médio para o completo desaparecimento da linha de fratura foi de 28±6,44 dias e para formação de calo ósseo, 17±3,26 dias. As aves, mesmo com o aparelho de fixação, retornaram ao vôo aos 28±1,2 dias, exceto uma que não recuperou a capacidade de vôo. A técnica de fixação externa demonstrou ser eficaz para o tratamento de fraturas diafisárias de úmero em pombos domésticos.Among the various pathologies that can inflict birds, the long bones fractures of the wings, and pelvic members are more commom. Fourteeen domestic pigeons (Columba livia weighing 290 to 420g, were submitted to open reduction of humeral diaphysis fracture with external fixator type Ia (unilateral-uniplanar in order to evaluate the clinical, histological and radiographic evolution of the bone healing. The external fixator device was stabilized with methilmetacrylate acrylic. The average time necessary to the complete disappearance of the fracture line by radiographic evaluation was 28±6.44 days. The bone callus was identified at 17±3.26 postoperative days. The birds returned to flying in 28±1.2 days yet with the fixation device and only one did not recovere the flying abillity. The external fixation technique is an efficient method to treat diaphiseal humeral fracture in domestic

  14. Intramedullary fixation of proximal humerus fractures: do locking bolts endanger the axillary nerve or the ascending branch of the anterior circumflex artery? A cadaveric study

    Directory of Open Access Journals (Sweden)

    Sermon An

    2008-12-01

    Full Text Available Abstract Background Proximal humerus fractures are one of the most common fractures. Intramedullary locked nailing is becoming a popular alternative treatment, especially for easier fracture patterns. Although axillary nerve injury has been reported, no study has compared the safety of the proximal locking options relative to the axillary nerve and the ascending branch of the anterior circumflex artery. Method Six different commercially available proximal humeral nails were implanted in 30 shoulders of 18 cadavers. After fluoroscopically guided implantation the shoulders were carefully dissected and the distance between the locking screws, the axillary nerve and the ascending branch of the anterior circumflex artery was measured. Results The course of the axillary nerve varies. A mean distance of 55.8 mm (SD = 5.3 between the lateral edge of the acromions and the axillary nerve at the middle of the humerus in a neutrally rotated position was observed. The minimum distance was 43.4 mm, the maximum 63.9 mm. Bent nails with oblique head interlocking bolts appeared to be the most dangerous in relation to the axillary nerve. The two designs featuring such a bend and oblique bolt showed a mean distance of the locking screw to the axillary nerve of 1 mm and 2.7 mm respectively Sirus (Zimmer® and (Stryker® T2 PHN (Proximal Humeral Nail. Regarding the ascending branch of the anterior circumflex artery, there was no difference between the nails which have an anteroposterior locking option. Conclusion It is of great importance for surgeons treating proximal humerus fractures to understand the relative risk of any procedure they perform. Since the designs of different nailing systems risk damaging the axillary nerve and ascending branch, blunt dissection, the use of protection sleeves during drilling and screw insertion, and individual risk evaluation prior to the use of a proximal humeral nail are advocated.

  15. How sensitive is the deltoid moment arm to humeral offset changes with reverse total shoulder arthroplasty?

    Science.gov (United States)

    Walker, David R; Kinney, Allison L; Wright, Thomas W; Banks, Scott A

    2016-06-01

    Reverse total shoulder arthroplasty commonly treats cuff-deficient or osteoarthritic shoulders not amenable to rotator cuff repair. This study investigates deltoid moment arm sensitivity to variations in the joint center and humeral offset of 3 representative reverse total shoulder arthroplasty subjects. We hypothesized that a superior joint implant placement may exist, indicated by muscle moment arms, compared with the current actual surgical implant configuration. Moment arms for the anterior, lateral, and posterior aspects of the deltoid muscle were determined for 1521 perturbations of the humeral offset location away from the surgical placement in a subject-specific musculoskeletal model with motion defined by subject-specific in vivo abduction kinematics. The humeral offset was varied from its surgical position ±4 mm in the anterior/posterior direction, ±12 mm in the medial/lateral direction, and -10 to 14 mm in the superior/inferior direction. The anterior deltoid moment arm varied in humeral offset and center of rotation up to 20 mm, primarily in the medial/lateral and superior/inferior directions. The lateral deltoid moment arm varied in humeral offset up to 20 mm, primarily in the medial/lateral and anterior/posterior directions. The posterior deltoid moment arm varied up to 15 mm, primarily in early abduction, and was most sensitive to humeral offset changes in the superior/inferior direction. High variations in muscle moment arms were found for all 3 deltoid components, presenting an opportunity to dramatically change the deltoid moment arms through surgical placement of the reverse shoulder components and by varying the overall offset of the humerus. Basic Science Study; Computer Modeling. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  16. Benefits and harms of locking plate osteosynthesis in intraarticular (OTA Type C) fractures of the proximal humerus: A systematic review

    DEFF Research Database (Denmark)

    Brorson, Stig; Rasmussen, Jeppe Vejlgaard; Frich, Lars Henrik

    2012-01-01

    stable plates in AO/OTA Type C fractures of the proximal humerus. METHODS: We conducted an iterative search in PubMed, Embase, Cochrane Library, Web of Science, Cinahl, and PEDro in all languages from 1999 to November 2010. Eligible studies should study the outcome for Type C fractures after primary...... according to study type and synthesised qualitatively. No randomised clinical trials were identified. Two comparative, observational studies reported a mean CS of 71 (relative to contralateral shoulder) and 75 (non-adjusted Constant Score) for Type C fractures. For all studies mean non-adjusted CS ranged......INTRODUCTION: Locking plate osteosynthesis of proximal humeral fractures are widely recommended and used, even in complex intraarticular fracture patterns such as AO/OTA Type C fractures. We systematically reviewed clinical studies assessing the benefits and harms of osteosynthesis with angle...

  17. Straight proximal humeral nails are surrounded by more bone stock in comparison to bent nails in an experimental cadaveric study.

    Science.gov (United States)

    Günther, Christian Max; Müller, Peter Ernst; Mutschler, Wolf; Sprecher, Christoph Martin; Milz, Stefan; Braunstein, Volker

    2014-01-01

    In the management of proximal humeral fractures intramedullary implants with bent and straight shape of the proximal part of nail are available. Based on data from previous studies on bone distribution in the humeral head, we hypothesized, that higher densities might exist in the bone stock surrounding straight nails in comparison to their angulated counterparts. With a known positive correlation between bone density and mechanical stability, this could indicate potentially higher rigidity of osteosyntheses done with straight implants. We performed high resolution peripheral quantitative computed tomographies of the potential straight and bent implant bearing regions of 27 cadaveric proximal humeri. The acquired data were analyzed for differences between straight and bent Volumes of Interest as well as intra- and interindividual bone stock distribution. For both straight and bent volumes of interest a considerably declining bone mineral density was found in craniocaudal direction. Mean densities of bent volumes were significantly lower in comparison to their corresponding straight counterparts (p straight shaped implants can be assumed. Since we found a rapid decrease of bone density in cranio-caudal direction, intramedullary implants should be anchored as proximally in the subcortical area as possible to minimize the risk of displacement or cutout. The high correlation between the Volumes of Interest of the corresponding right and left sides could aid in preoperative planning when considering an intra- or extramedullary approach.

  18. Tibial shaft fractures in football players

    Directory of Open Access Journals (Sweden)

    Daisley Susan

    2007-06-01

    Full Text Available Abstract Background Football is officially the most popular sport in the world. In the UK, 10% of the adult population play football at least once a year. Despite this, there are few papers in the literature on tibial diaphyseal fractures in this sporting group. In addition, conflicting views on the nature of this injury exist. The purpose of this paper is to compare our experience of tibial shaft football fractures with the little available literature and identify any similarities and differences. Methods and Results A retrospective study of all tibial football fractures that presented to a teaching hospital was undertaken over a 5 year period from 1997 to 2001. There were 244 tibial fractures treated. 24 (9.8% of these were football related. All patients were male with a mean age of 23 years (range 15 to 29 and shin guards were worn in 95.8% of cases. 11/24 (45.8% were treated conservatively, 11/24 (45.8% by Grosse Kemp intramedullary nail and 2/24 (8.3% with plating. A difference in union times was noted, conservative 19 weeks compared to operative group 23.9 weeks (p Conclusion Our series compared similarly with the few reports available in the literature. However, a striking finding noted by the authors was a drop in the incidence of tibial shaft football fractures. It is likely that this is a reflection of recent compulsory FIFA regulations on shinguards as well as improvements in the design over the past decade since its introduction.

  19. Humeral lengthening and proximal deformity correction with monorail external fixator in young adults.

    Science.gov (United States)

    Ruan, Hongjiang; Zhu, Yi; Liu, Shen; Kang, Qinglin

    2018-05-01

    Several humeral lengthening or simultaneous deformity corrections through one osteotomy using various external fixators were reported, while literature regarding correction of shortening and proximal varus deformity is scarce. This retrospective clinical study evaluated the results of preforming an acute correction and delayed lengthening in young adults through two osteotomies using monorail external fixator. We report seven patients with various pathologies who underwent humeral proximal deformity correction and lengthening between 2009 and 2015. Pre-operative and post-operative clinical and radiographic data were collected. The mean follow-up time was 33.4 months (25-46 months). The humeral neck-shaft angle improved from 97.9° (85-110°) to 138.6° (135-145°). The magnitude of lengthening achieved was average 7.6 cm (range, 6-10 cm) at an average healing index of lengthening of 30.2 days/cm (range, 27.7-35.4 days/cm). There was a significant increase in range of shoulder abduction, and active abduction improved from pre-operative 136.4° (range, 95-160°) to post-operative 166.4° (range, 150-180°). The DASH score improved significance from 23.29 ± 8.36 to 6.57 ± 3.65 (t = 4.848; p monorail external fixator can be used for humeral shortening and proximal varus angular deformity. Functional improvement is expected after surgery and post-operative therapy.

  20. The epidemiology of fractures in infants--Which accidents are preventable?

    Science.gov (United States)

    Wegmann, Helmut; Orendi, Ingrid; Singer, Georg; Eberl, Robert; Castellani, Christoph; Schalamon, Johannes; Till, Holger

    2016-01-01

    In children, fractures have a huge impact on the health care system. In order to develop effective prevention strategies exact knowledge about the epidemiology of fractures is mandatory. This study aims to describe clinical and epidemiological data of fractures diagnosed in infants. A retrospective analysis of all infants (childrenfractures in an 11 years period (2001-2011) was performed. Information was obtained regarding the location of the fractures, sites of the accident, circumstances and mechanisms of injury and post-injury care. 248 infants (54% male, 46% female) with a mean age of 7 months presented with 253 fractures. In more than half of the cases skull fractures were diagnosed (n=151, 61%). Most frequently the accidents causing fractures happened at home (67%). Falls from the changing table, from the arm of the care-giver and out of bed were most commonly encountered (n=92, 37%). While the majority of skull fractures was caused from falls out of different heights, external impacts tended to lead to fractures of the extremities. 6 patients (2%) were victims of maltreatment and sustained 10 fractures (2 skull fractures, 4 proximal humeral fractures, 2 rib fractures, and 2 tibial fractures). Falls from the changing table, the arms of the caregivers and out of bed caused the majority of fractures (especially skull fracture) in infants. Therefore, awareness campaigns and prevention strategies should focus on these mechanisms of accident in order to decrease the rate of fractures in infants. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. [Trochanteric femoral fractures: anatomy, biomechanics and choice of implants].

    Science.gov (United States)

    Bonnaire, F; Lein, T; Bula, P

    2011-06-01

    The objective of any surgical care of a trochanteric femoral fracture should be the achievement of a stable osteosynthesis that allows early full weight-bearing mobilisation of the patient, because long-term immobilisation soon becomes a vital threat to the affected patients who are usually elderly with correlating comorbidities. The anatomical references of the proximal femur and the structure of the hip joint contain some specifics that play an essential role in the incurrence of a trochanteric femoral fracture and the planning of the osteosynthesis as well. With reposition and fracture stabilisation particular importance must be attached to the collo-diaphyseal and the antetorsion angle so that they do not interfere with the functional interaction of the hip and knee joint. Uncomplex trochanteric fractures ordinarily stabilise sufficiently after reposition so that even an extramedullary implant can ensure full weight-bearing stability. With evermore distal fracture course and intertrochanteric comminution zone, rotational instability and pivot transfer of the fracture area to lateral and caudal are followed by an increase of the dislocating forces. These kinds of fractures (A2 and A3 according to the AO/ASIF classification) profit from an intramedullary and rotationally stable osteosynthesis. Basically primary total hip arthroplasty is a potential option for surgical care of a trochanteric fracture in elderly patients with relevant coxarthrosis. However this procedure can only be recommended in cases of a stable uncomplex fracture. The more the medial interlocking of the proximal femur is destroyed the more difficult it will be to primarily implant a total hip prosthesis with good offset and without a varus and rotational failure in the fracture zone.The current studies in the main show disadvantages due to increased complications in these patients, so that in cases of an unstable trochanteric fracture a primary osteosynthesis should be performed followed by

  2. Unicameral bone cyst of the humeral head: arthroscopic curettage and bone grafting.

    Science.gov (United States)

    Randelli, Pietro; Arrigoni, Paolo; Cabitza, Paolo; Denti, Matteo

    2009-01-01

    Arthroscopic surgery has improved greatly over the past decade. Treatment of various juxta-articular disorders around the shoulder have benefited from endoscopic approaches. Cystic lesions of the shoulder on the scapular side have been treated in this way. This article describes a case of a 29-year-old patient with a unicameral bone cyst on the posterior aspect of the humeral head. Arthroscopic visualization using an accessory posteroinferior portal localized the cyst through the bare area of the humeral head. A cannulated burr was used to create an opening through the cortical wall between the cyst and the joint, and a careful curettage was performed. The cavity was filled with a demineralized bone matrix enriched with autologous blood packed into an arthroscopic cannula and delivered through the accessory portal. The patient reported pain relief immediately postoperatively and at follow-up. This case demonstrates the feasibility of arthroscopic treatment of a simple bone cyst of the humeral head. We believe that the knowledge of the juxta-articular anatomy allows the applications of scope-assisted procedures to be expanded, maximizing the results of a technique that allows a shorter recovery and less painful rehabilitation.

  3. Throwing in the Middle and Upper Paleolithic: inferences from an analysis of humeral retroversion.

    Science.gov (United States)

    Rhodes, Jill A; Churchill, Steven E

    2009-01-01

    When in evolutionary history did long-range projectile weapons become an important component of hunting toolkits? The archeological evidence for the development of projectile weaponry is complex and generally indirect, and has led to different conclusions about the origin and spread of this technology. Lithic evidence from the Middle Stone Age (MSA) has led some researchers to suggest that true long- range projectile weaponry developed in Africa perhaps as early as 80,000 years ago, and was part of the subsistence toolkit carried by modern humans who expanded out of Africa after 50,000 years ago. Alternatively, temporal patterns in the morphology of pointed lithics has led others to posit an independent, convergent origin of projectile weaponry in Africa, the Near East, and Europe during the interval between 50,000-40,000 years ago. By either scenario, projectile weapons would not have been a component of the hunting arsenal of Neandertals, but may have been in use by European early modern humans and thus, projectile technology may have entered into the competitive dynamics that existed between these two groups. The origins of projectile weapons can be addressed, in part, through analyses of the skeletal remains of the prehistoric humans who made and used them. Habitual behavior patterns--including those related to the production and use of technology--can be imprinted on the skeleton through both genetic and epigenetic pathways. Recent studies in the field of sports medicine indicate that individuals who engage in habitual throwing have increased humeral retroversion angles in their throwing arms and a greater degree of bilateral asymmetry in retroversion angles than do non-throwers. This contribution investigates humeral torsion through analysis of the retroversion angle in samples of Eurasian Neandertals, European early modern humans of the middle and late Upper Paleolithic, and comparative samples of recent humans. This analysis was conducted under the

  4. Effect of osteosynthesis, primary hemiarthroplasty, and non-surgical management for displaced four-part fractures of the proximal humerus in elderly

    DEFF Research Database (Denmark)

    Brorson, Stig; Olsen, Bo Sanderhoff; Frich, Lars Henrik

    2009-01-01

    BACKGROUND: Fractures of the proximal humerus are common injuries and account for 4-5 percent of all fractures, second only to hip and wrist fractures. The incidence is positively correlated with age and osteoporosis, and is likely to increase. Displaced four-part fractures are among the most...... severe injuries, accounting for 2-10 percent of proximal humeral fractures. The optimal intervention is disputed. Two previous randomised trials were very small and involved a noticeable risk of bias, and systematic reviews consequently conclude that there is inadequate basis for evidence-based treatment...... ten national shoulder units within a two-year period. We plan to include 162 patients. A central randomisation unit will allocate patients. All patients will receive a standardised three-month rehabilitation program of supervised physiotherapy regardless of treatment allocation. Patients...

  5. Case of femoral diaphyseal stress fracture after long-term risedronate administration diagnosed by iliac bone biopsy

    Directory of Open Access Journals (Sweden)

    Nagai T

    2013-04-01

    Full Text Available Takashi Nagai, Keizo Sakamoto, Koji Ishikawa, Emi Saito, Takuma Kuroda, Katsunori Inagaki Department of Orthopaedic Surgery, Showa University School of Medicine, Shinagwa-ku, Tokyo, Japan Abstract: Bisphosphonate excessively inhibits bone resorption and results in pathological fracture of the femur or ilium. The subject of this study was administered risedronate for 7 years; we suspected an easy fracture of the femoral diaphysis. In this study, we report the results of this patient's bone biopsy and bone morphometric analysis. A 76-year-old female patient presented with right femoral pain. Bone mineral density of the anteroposterior surface of the 2nd to 4th lumbar vertebrae (L2-L4 was decreased and levels of bone turnover markers were high. Therefore, we initiated treatment with risedronate. As she continued the medication, urinary levels of cross-linked N-terminal telopeptides of type I collagen and alkaline phosphatase (bone-type isozyme were found to be within the normal ranges. After 7 years of administration, the patient experienced pain when she put weight on the right femur and right femoral pain while walking. Plain radiographic examination revealed polypoid stress fracture-like lesions on the right femoral diaphysis and on the slightly distal-lateral cortical bone. Similar lesions were observed on magnetic resonance imaging and bone scintigraphy. We suspected severely suppressed bone turnover. Bone biopsy was obtained after labeling with tetracycline, and bone morphometric analysis was performed. On microscopic examination, slight double tetracycline labeling was observed. The trabeculae were narrow, and the numbers of osteoblasts and osteoclasts were decreased. Further, rates of bone calcification and bone formation were slow. Hence, we diagnosed fracture as a result of low turnover osteopathy. Risedronate was withdrawn, and Vitamin D3 was administered to improve the bone turnover. At 6 months, abnormal signals on magnetic resonance

  6. Preliminary experience with biodegradable implants for fracture fixation

    Directory of Open Access Journals (Sweden)

    Dhillon Mandeep

    2008-01-01

    Full Text Available Background: Biodegradable implants were designed to overcome the disadvantages of metal-based internal fixation devices. Although they have been in use for four decades internationally, many surgeons in India continue to be skeptical about the mechanical strength of biodegradable implants, hence this study. Materials and Methods: A prospective study was done to assess the feasibility and surgeon confidence level with biodegradable implants over a 12-month period in an Indian hospital. Fifteen fractures (intra-articular, metaphyseal or small bone fractures were fixed with biodegradable implants. The surgeries were randomly scheduled so that different surgeons with different levels of experience could use the implants for fixation. Results: Three fractures (one humeral condyle, two capitulum, were supplemented by additional K-wires fixation. Trans-articular fixator was applied in two distal radius and two pilon fractures where bio-pins alone were used. All fractures united, but in two cases the fracture displaced partially during the healing phase; one fibula due to early walking, and one radius was deemed unstable even after bio-pin and external fixator. Conclusions: Biodegradable -implants are excellent for carefully selected cases of intra-articular fractures and some small bone fractures. However, limitations for use in long bone fractures persist and no great advantage is gained if a "hybrid" composite is employed. The mechanical properties of biopins and screws in isolation are perceived to be inferior to those of conventional metal implants, leading to low confidence levels regarding the stability of reduced fractures; these implants should be used predominantly in fracture patterns in which internal fixation is subjected to minimal stress.

  7. CURBSIDE CONSULTATION IN FRACTURE MANAGEMENT: 49 CLINICAL QUESTIONS

    Directory of Open Access Journals (Sweden)

    Walter W. Virkus

    2008-12-01

    Full Text Available DESCRIPTION: A user-friendly, unique resource for the treatment of fractures designed in a casual questions and answers format which provides basic knowledge, current information and evidence based expert advices enhanced by images and diagrams and supported by ref-erences.PURPOSE: Designing this book the editor has aimed to prepare not only a source of current knowledge and opin-ions by experienced authors in fracture management for decision making in daily practice but also a brief refer-ence and useful educational resource in orthopedic trauma surgery.FEATURES: Three Sections are composed of 49 sub-jects in a form of the answers of frequently asked ques-tions richly illustrated by images and diagrams and in-cluding references at the end of each subject.The Section I is “UPPER EXTREMITIES” including: Neck fracture; Humerus shaft fracture; Management of radial nerve palsy associated with humeral fracture; Clavicle fractures; Elbow fractures in children; Fasciot-omy technic of the forearm; Distal radius fracture; Indica-tions of radial head replacement, Femur and humeral shaft fractures; Treatment of posterolateral elbow dislocation; The Section II is “LOWER EXTREMITIES” including : Femur fractures; Pelvic fractures; Life threatening pelvic fractures; Decision for surgical treatment in pelvic frac-tures; Treatment of anterior fracture of femoral head and hip joint incongruity; Management of a displaced femoral neck fracture in young patient in ER; Elder patients with displaced femoral head fracture; Patella and tibial plateau fractures; Criteria for compartment syndromes in the tibia; Tricks in nailing proximal and distal tibial fractures; Surgical management of distal tibia spiral fracture in middle aged women; Pilon fracture; Management of syn-desmotic screws in adult patient; The management of minimally displaced posterior malleol in three malleolar fractures; Postoperative management of bimalleolar frac-tures; Management of minimally

  8. ARTHROSCOPIC TREATMENT OF PATIENTS WITH LATERAL HUMERAL EPICONDYLITIS (TENNIS ELBOW

    Directory of Open Access Journals (Sweden)

    M. R. Salikhov

    2017-01-01

    Full Text Available In the past decade the clinical and anatomical studies proved that lateral humeral epicondylitis can be successfully treated arthroscopically.Purpose of the study is to identify the optimal method of surgical treatment for patients with lateral humeral epicondylitis.Material and methods. The authors conducted an integral study consisting of two sections: clinical and anatomical. Anatomical section included precision preparation of extensor muscles of the forearm. Clinical section was dedicated to comparative analysis of statistically valid and matched by lesion severity groups of patients who underwent open and arthroscopic procedures. All patients were divided into three groups. Patients of Group I underwent arthroscopic release of extensor carpi radialis brevis tendon (ECRB without decorticating of the lateral humeral epicondyle. Patients of Group II underwent arthroscopic release of ECRB in combination with decortication of the lateral humeral epicondyle. Patients in Group III underwent an open release of ECRB.Results. Patients who underwent arthroscopic release of ECRB demonstrated less pronounced pain syndrome as compared to patients after ECRB release along with decortication of epicondyle or after open release (р<0,05. VAS pain score in Group I decreased from 7 to 1 point, in Group II — from 7 to 3 points, in Group III — from 7 to 4 points. Mean time until full recovery after the surgery was 24,2±7,8 days in Group I, 39,4±5,6 days in Group II and 60,2±15,6 days in Group III (р<0,05. Functional outcomes were assessed by Mayo Elbow Performance Score (MEPS in 9 weeks postoperatively: Group I — improvement from 60 to 79 points, Group II — from 62 to 75 points, Group III — from 60 to 75 points.Conclusion. Drilling or removal of periosteum of the damaged epicondyle does not provide a positive effect. Decortication also has certain disadvantages like postoperative pain intensification leading to lesser range of motion in elbow and

  9. Pseudoaneurysm of the posterior circumflex humeral artery diagnosed by sonography

    DEFF Research Database (Denmark)

    Damgaard, Bodil; Court-Payen, Michel; Larsen, Lone

    2009-01-01

    with a painless, nonpulsatile mass in the posterior shoulder region and was suspected of a malignant soft-tissue tumor. Sonography, including power Doppler imaging, demonstrated a pseudoaneurysm, with the intralesional blood-filled cavity developed from the posterior circumflex humeral artery. The diagnosis...

  10. Osteochondritis dissecans of the humeral capitellum: reliability of four classification systems using radiographs and computed tomography.

    Science.gov (United States)

    Claessen, Femke M A P; van den Ende, Kimberly I M; Doornberg, Job N; Guitton, Thierry G; Eygendaal, Denise; van den Bekerom, Michel P J

    2015-10-01

    The radiographic appearance of osteochondritis dissecans (OCD) of the humeral capitellum varies according to the stage of the lesion. It is important to evaluate the stage of OCD lesion carefully to guide treatment. We compared the interobserver reliability of currently used classification systems for OCD of the humeral capitellum to identify the most reliable classification system. Thirty-two musculoskeletal radiologists and orthopaedic surgeons specialized in elbow surgery from several countries evaluated anteroposterior and lateral radiographs and corresponding computed tomography (CT) scans of 22 patients to classify the stage of OCD of the humeral capitellum according to the classification systems developed by (1) Minami, (2) Berndt and Harty, (3) Ferkel and Sgaglione, and (4) Anderson on a Web-based study platform including a Digital Imaging and Communications in Medicine viewer. Magnetic resonance imaging was not evaluated as part of this study. We measured agreement among observers using the Siegel and Castellan multirater κ. All OCD classification systems, except for Berndt and Harty, which had poor agreement among observers (κ = 0.20), had fair interobserver agreement: κ was 0.27 for the Minami, 0.23 for Anderson, and 0.22 for Ferkel and Sgaglione classifications. The Minami Classification was significantly more reliable than the other classifications (P reliable for classifying different stages of OCD of the humeral capitellum. However, it is unclear whether radiographic evidence of OCD of the humeral capitellum, as categorized by the Minami Classification, guides treatment in clinical practice as a result of this fair agreement. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  11. Ipsilateral simultaneous fracture of the trochlea involving the lateral end clavicle and distal end radius: a rare combination and a unique mechanism of injury

    Directory of Open Access Journals (Sweden)

    Gupta RK

    2014-07-01

    Full Text Available 【Abstract】Isolated trochlea fracture in adults is a rare surgical entity as compared to its capitellar counterpart. It has been only mentioned sporadically in the literature as case reports. Fracture of the trochlea is accompanied by other elbow injuries like elbow dislocation, capitellum fracture, ulnar fracture and extraarticular condylar fracture. Here we report a unique case of isolated displaced trochlea fracture associated with fractures of the lateral end clavicle and the distal end radius. We propose a unique mechanism for this rare combination of injuries: typical triad of injury, i.e. fracture of the distal end radius with trochlea and fracture of the lateral end of the clavicle. Nonoperative treatment is recommended for undisplaced humeral trochlea fractures; but for displaced ones, anatomical reduction and internal fixation are essential to maintain the congruous trochleacoronoid articulation and hence to maintain the intrinsic stability of the elbow. Key words: Isolated trochlea fracture; Clavicle; Radius fractures

  12. Exogenous PTHrP Repairs the Damaged Fracture Healing of PTHrP+/− Mice and Accelerates Fracture Healing of Wild Mice

    Science.gov (United States)

    Wang, Yinhe; Fang, Xin; Wang, Chun; Ding, Congzhu; Lin, Hua; Liu, Anlong; Wang, Lei; Cao, Yang

    2017-01-01

    Bone fracture healing is a complicated physiological regenerative process initiated in response to injury and is similar to bone development. To demonstrate whether an exogenous supply of parathyroid hormone–related protein (PTHrP) helps in bone fracture healing, closed mid-diaphyseal femur fractures were created and stabilized with intramedullary pins in eight-week-old wild-type (WT) PTHrP+/+ and PTHrP+/− mice. After administering PTHrP for two weeks, callus tissue properties were analyzed at one, two, and four weeks post-fracture (PF) by various methods. Bone formation–related genes and protein expression levels were evaluated by real-time reverse transcriptase–polymerase chain reaction and Western blots. At two weeks PF, mineral density of callus, bony callus areas, mRNA levels of alkaline phosphatase (ALP), type I collagen, Runt-related transcription factor 2 (Runx-2), and protein levels of Runx-2 and insulin-like growth factor-1 decreased in PTHrP+/− mice compared with WT mice. At four weeks PF, total collagen-positive bony callus areas, osteoblast number, ALP-positive areas, and type I collagen-positive areas all decreased in PTHrP+/− mice. At both two and four weeks PF, tartrate-resistant acid phosphatase–positive osteoclast number and surface decreased a little in PTHrP+/− mice. The study indicates that exogenous PTHrP provided by subcutaneous injection could redress impaired bone fracture healing, leading to mutation of activated PTHrP by influencing callus areas, endochondral bone formation, osteoblastic bone formation, and bone turnover. PMID:28178186

  13. Exogenous PTHrP Repairs the Damaged Fracture Healing of PTHrP+/− Mice and Accelerates Fracture Healing of Wild Mice

    Directory of Open Access Journals (Sweden)

    Yinhe Wang

    2017-02-01

    Full Text Available Bone fracture healing is a complicated physiological regenerative process initiated in response to injury and is similar to bone development. To demonstrate whether an exogenous supply of parathyroid hormone–related protein (PTHrP helps in bone fracture healing, closed mid-diaphyseal femur fractures were created and stabilized with intramedullary pins in eight-week-old wild-type (WT PTHrP+/+ and PTHrP+/− mice. After administering PTHrP for two weeks, callus tissue properties were analyzed at one, two, and four weeks post-fracture (PF by various methods. Bone formation–related genes and protein expression levels were evaluated by real-time reverse transcriptase–polymerase chain reaction and Western blots. At two weeks PF, mineral density of callus, bony callus areas, mRNA levels of alkaline phosphatase (ALP, type I collagen, Runt-related transcription factor 2 (Runx-2, and protein levels of Runx-2 and insulin-like growth factor-1 decreased in PTHrP+/− mice compared with WT mice. At four weeks PF, total collagen-positive bony callus areas, osteoblast number, ALP-positive areas, and type I collagen-positive areas all decreased in PTHrP+/− mice. At both two and four weeks PF, tartrate-resistant acid phosphatase–positive osteoclast number and surface decreased a little in PTHrP+/− mice. The study indicates that exogenous PTHrP provided by subcutaneous injection could redress impaired bone fracture healing, leading to mutation of activated PTHrP by influencing callus areas, endochondral bone formation, osteoblastic bone formation, and bone turnover.

  14. Successful reimplantation of extruded long bone segments in open fractures of lower limb--a report of 3 cases.

    Science.gov (United States)

    Shanmuganathan, Rajasekaran; Chandra Mohan, Arun Kamal; Agraharam, Devendra; Perumal, Ramesh; Jayaramaraju, Dheenadhayalan; Kulkarni, Sunil

    2015-07-01

    Extruded bone segments are rare complication of high energy open fractures. Routinely these fractures are treated by debridement followed by bone loss management in the form of either bone transport or free fibula transfer. There are very few reports in the literature about reimplantation of extruded segments of bone and there are no clear guidelines regarding timing of reimplantation, bone stabilisation and sterilisation techniques. Reimplantation of extruded bone is a risky procedure due to high chances of infection which determines the final outcome and can result in secondary amputations. We present two cases of successful reimplantation of extruded diaphyseal segment of femur and one case of reimplantation of extruded segment of tibia. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Trochanteric fragility fractures : Treatment using the cement-augmented proximal femoral nail antirotation.

    Science.gov (United States)

    Neuerburg, C; Mehaffey, S; Gosch, M; Böcker, W; Blauth, M; Kammerlander, C

    2016-06-01

    Use of standardized cement augmentation of the proximal femur nail antirotation (PFNA) for the treatment of trochanteric fragility fractures, which are associated with high morbidity and mortality, to achieve safer conditions for immediate full weight-bearing and mobilization, thus, improving preservation of function and independency of orthogeriatric patients. Trochanteric fragility fractures (type 31-A1-3). Ipsilateral arthritis of the hip, leakage of contrast agent into the hip joint, femoral neck fractures. Reduction of the fracture on a fracture table if possible, or minimally invasive open reduction of the proximal femur, i. e., using collinear forceps if necessary. Positioning of guidewires for adjustment of the PFNA and the spiral blade, respectively. Exclusion of leakage of contrast agent and subsequent injection of TRAUMACEM™ V(+) into the femoral head-neck fragment via a trauma needle kit introduced into the spiral blade. Dynamic or static locking of the PFNA at the diaphyseal level. Immediate mobilization of the patients with full weight-bearing and secondary prevention, such as osteoporosis management is necessary to avoid further fractures in the treatment of these patients. A total of 110 patients older than 65 years underwent the procedure. Of the 72 patients available for follow-up (average age 85.3 years), all fractures healed after an average of 15.3 months. No complications related with cement augmentation were observed. Approximately 60 % of patients achieved the mobility level prior to trauma.

  16. Burden of high fracture probability worldwide: secular increases 2010-2040.

    Science.gov (United States)

    Odén, A; McCloskey, E V; Kanis, J A; Harvey, N C; Johansson, H

    2015-09-01

    The number of individuals aged 50 years or more at high risk of osteoporotic fracture worldwide in 2010 was estimated at 158 million and is set to double by 2040. The aim of this study was to quantify the number of individuals worldwide aged 50 years or more at high risk of osteoporotic fracture in 2010 and 2040. A threshold of high fracture probability was set at the age-specific 10-year probability of a major fracture (clinical vertebral, forearm, humeral or hip fracture) which was equivalent to that of a woman with a BMI of 24 kg/m(2) and a prior fragility fracture but no other clinical risk factors. The prevalence of high risk was determined worldwide and by continent using all available country-specific FRAX models and applied the population demography for each country. Twenty-one million men and 137 million women had a fracture probability at or above the threshold in the world for the year 2010. The greatest number of men and women at high risk were from Asia (55 %). Worldwide, the number of high-risk individuals is expected to double over the next 40 years. We conclude that individuals with high probability of osteoporotic fractures comprise a very significant disease burden to society, particularly in Asia, and that this burden is set to increase markedly in the future. These analyses provide a platform for the evaluation of risk assessment and intervention strategies.

  17. The factors influencing the decision making of operative treatment for proximal humeral fractures

    NARCIS (Netherlands)

    Hageman, Michiel G. J. S.; Jayakumar, Prakash; King, John D.; Guitton, Thierry G.; Doornberg, Job N.; Ring, David

    2015-01-01

    The factors influencing the decision making of operative treatment for fractures of the proximal humerus are debated. We hypothesized that there is no difference in treatment recommendations between surgeons shown radiographs alone and those shown radiographs and patient information. Secondarily, we

  18. The factors influencing the decision making of operative treatment for proximal humeral fractures

    NARCIS (Netherlands)

    Hageman, M.G.; Jayakumar, P.; King, J.D.; Guitton, T.G.; Doornberg, J.N.; Ring, D.; Poelhekke, L.M.S.J.; et al.,

    2015-01-01

    BACKGROUND: The factors influencing the decision making of operative treatment for fractures of the proximal humerus are debated. We hypothesized that there is no difference in treatment recommendations between surgeons shown radiographs alone and those shown radiographs and patient information.

  19. Surgeons agree more on treatment recommendations than on classification of proximal humeral fractures

    DEFF Research Database (Denmark)

    Brorson, Stig; Olsen, Bo Sanderhoff; Frich, Lars Henrik

    2012-01-01

    Orthopaedic surgeons disagree considerably when classifying fractures of the proximal humerus. However, the clinical implications of low observer agreement remain unclear. The purpose of the study was to compare the agreement on Neer classification with the agreement on treatment recommendations....

  20. Is Early Appropriate Care of axial and femoral fractures appropriate in multiply-injured elderly trauma patients?

    Science.gov (United States)

    Reich, M S; Dolenc, A J; Moore, T A; Vallier, H A

    2016-09-26

    Previous work established resuscitation parameters that minimize complications with early fracture management. This Early Appropriate Care (EAC) protocol was applied to patients with advanced age to determine if they require unique parameters to mitigate complications. Between October 2010 and March 2013, 376 consecutive skeletally mature patients with unstable fractures of the pelvis, acetabulum, thoracolumbar spine, and/or proximal or diaphyseal femur fractures were treated at a level I trauma center and were prospectively studied. Patients aged ≤30 years (n = 114), 30 to 60 years (n = 184), and ≥60 years (n = 37) with Injury Severity Scores (ISS) ≥16 and unstable fractures of the pelvis, acetabulum, spine, and/or diaphyseal femur were treated within 36 h, provided they showed evidence of adequate resuscitation. ISS, Glasgow Coma Scale (GCS), and American Society of Anesthesiologists (ASA) classification were determined. Lactate, pH, and base excess (BE) were measured at 8-h intervals. Complications included pneumonia, pulmonary embolism (PE), acute renal failure, acute respiratory distress syndrome (ARDS), multiple organ failure (MOF), deep vein thrombosis, infection, sepsis, and death. Patients ≤30 years old (y/o) were more likely to sustain gunshot wounds (p = 0.039), while those ≥60 y/o were more likely to fall from a height (p = 0.002). Complications occurred at similar rates for patients ≤30 y/o, 30 to 60 y/o, and ≥60 y/o. There were no differences in lactate, pH, or BE at the time of surgery. For patients ≤30 y/o, there were increased overall complications if pH was <7.30 (p = 0.042) or BE <-6.0 (p = 0.049); patients ≥60 y/o demonstrated more sepsis if BE was <-6.0 (p = 0.046). EAC aims to definitively manage axial and femoral shaft fractures once patients have been adequately resuscitated to minimize complications. EAC is associated with comparable complication rates in young and elderly

  1. Traumatic humeral articular cartilage shear (THACS) lesion in a professional rugby player: a case report.

    Science.gov (United States)

    Jeon, I-H; Wallace, W A

    2004-08-01

    A 20 year old male professional rugby player was seen at the clinic for evaluation of shoulder pain after rugby play. Magnetic resonance imaging showed extensive subchondral bone bruising of the humeral head with defect of the articular cartilage. Arthroscopy showed that the inferior half of the humeral head had extensive articular cartilage loss with nearly 70% of the inferior head having lost its cartilage. Sports medicine doctors should be aware that the shoulder joint in young competitive athletes playing contact sports may be exposed to greater risk of this kind of injury.

  2. Pediatric femur fractures, epidemiology and treatment

    Directory of Open Access Journals (Sweden)

    Petković Lazar

    2011-01-01

    Full Text Available Background/Aim. Femur fractures in children most often occur as a consequence of traffic accidents, during play and sport activities, and due to different pathological states. Diagnosis is rather simple and it includes physical and radiographycal examination. Femur fractures treatment in children can be operative and unoperative, depending on several facts: age, localisation and type of fracture, joint injuries of soft tissues, the presence of other injuries (in polytrauma, economical and social aspects, ect. The aim of this study was to present epidemiological characteristics of pediatric femur fractures, that is in the stage of development, including a special analysis of the used treatment techniques, as well as the comparison of the obtained data with those from the literature. Methods. The evaluation included following parameters: age, gender, cause, localisation and type of femur fracture, applied treatment and hospitalisation duration. Results. Among the presented 143 patients with femur fracture, 109 were boys and 34 were girls (3.2 : 1 ratio; p = 0.0001. Average age for both genders was 8.6 years, and no difference between boys and girls were found for the age (p = 0.758. In total, the most common fracture was diaphyseal fracture of femur in 93 (65.03% patients. The second was proximal fracture in 30 (20.98% patients, and the last distal fracture of the femur in 20 (13.99% patients (p = 0.0001. Three main causes of femur fracture can be distinguished: during play and sport activities in 67 (46.8% children, in traffic accidents in 64 (44.8% children, and pathological fractures in 12 (8.4% children. Inoperative treatment was applied in 82 (57.3% patients, and operative one in 61 (42.7% patients. The most common tretament was traction, in 71 (49.6% patients, followed by immobilization by hip spica cast mostly in young children. Intramedullar elastic nailing was applied in 16 (11.2% cases, and intramedullar rigid nailing (Küntscher in 19

  3. Mechanical stimulation enhanced estrogen receptor expression and callus formation in diaphyseal long bone fracture healing in ovariectomy-induced osteoporotic rats.

    Science.gov (United States)

    Chow, S K H; Leung, K S; Qin, J; Guo, A; Sun, M; Qin, L; Cheung, W H

    2016-10-01

    Estrogen receptor (ER) in ovariectomy-induced osteoporotic fracture was reported to exhibit delayed expression. Mechanical stimulation enhanced ER-α expression in osteoporotic fracture callus at the tissue level. ER was also found to be required for the effectiveness of vibrational mechanical stimulation treatment in osteoporotic fracture healing. Estrogen receptor(ER) is involved in mechanical signal transduction in bone metabolism. Its expression was reported to be delayed in osteoporotic fracture healing. The purpose of this study was to investigate the roles played by ER during osteoporotic fracture healing enhanced with mechanical stimulation. Ovariectomy-induced osteoporotic SD rats that received closed femoral fractures were divided into five groups, (i) SHAM, (ii) SHAM-VT, (iii) OVX, (iv) OVX-VT, and (v) OVX-VT-ICI, where VT stands for whole-body vibration treatment and ICI for ER antagonization by ICI 182,780. Callus formation and gene expression were assessed at 2, 4, and 8 weeks postfracture. In vitro osteoblastic differentiation, mineralization, and ER-α expression were assessed. The delayed ER expression was found to be enhanced by vibration treatment. Callus formation enhancement was shown by callus morphometry and micro-CT analysis. Enhancement effects by vibration were partially abolished when ER was modulated by ICI 182,780, in terms of callus formation capacity at 2-4 weeks and ER gene and protein expression at all time points. In vitro, ER expression in osteoblasts was not enhanced by VT treatment, but osteoblastic differentiation and mineralization were enhanced under estrogen-deprived condition. When osteoblastic cells were modulated by ICI 182,780, enhancement effects of VT were eliminated. Vibration was able to enhance ER expression in ovariectomy-induced osteoporotic fracture healing. ER was essential in mechanical signal transduction and enhancement in callus formation effects during osteoporotic fracture healing enhanced by vibration

  4. Bilateral Atraumatic Avascular Necrosis of Both the Humeral and Femoral Heads due to the Corticosteroid Usage

    Directory of Open Access Journals (Sweden)

    Okkes Bilal

    2013-08-01

    Full Text Available Avascular necrosis is frequently associated with femoral head involvement and may also be observed in the knee joint, humeral head, wrist and foot. Avascular necrosis may also affect multiple joints. Bilateral involvement of both humeral and femoral heads is a rare condition in the same patient. A patient who complained about a sustained pain in both of his shoulders and hips for a few years applied to our outpatient clinic. The patient who had oral steroid treatment episodically was diagnosed with ulcerative colitis seven years ago. Arthroscopy-assisted decompression to the shoulder joints and core decompression to both hip joints were applied. The range of motions of both humeral and femoral joints was limited and painful prior to the surgical treatment. A follow-up after five years later showed that the patient's range of motions of joints was normal and no further treatment was necessary. [Arch Clin Exp Surg 2013; 2(4.000: 246-250

  5. Humeral external rotation handling by using the Bobath concept approach affects trunk extensor muscles electromyography in children with cerebral palsy.

    Science.gov (United States)

    Grazziotin Dos Santos, C; Pagnussat, Aline S; Simon, A S; Py, Rodrigo; Pinho, Alexandre Severo do; Wagner, Mário B

    2014-10-20

    This study aimed to investigate the electromyographic activity of cervical and trunk extensors muscles in children with cerebral palsy during two handlings according to the Bobath concept. A crossover trial involving 40 spastic diplegic children was conducted. Electromyography (EMG) was used to measure muscular activity at sitting position (SP), during shoulder internal rotation (IR) and shoulder external rotation (ER) handlings, which were performed using the elbow joint as key point of control. Muscle recordings were performed at the fourth cervical (C4) and at the tenth thoracic (T10) vertebral levels. The Gross Motor Function Classification System (GMFCS) was used to assess whether muscle activity would vary according to different levels of severity. Humeral ER handling induced an increase on EMG signal of trunk extensor muscles at the C4 (P=0.007) and T10 (P<0.001) vertebral levels. No significant effects were observed between SP and humeral IR handling at C4 level; However at T10 region, humeral IR handling induced an increase of EMG signal (P=0.019). Humeral ER resulted in an increase of EMG signal at both levels, suggesting increase of extensor muscle activation. Furthermore, the humeral ER handling caused different responses on EMG signal at T10 vertebra level, according to the GMFCS classification (P=0.017). In summary, an increase of EMG signal was observed during ER handling in both evaluated levels, suggesting an increase of muscle activation. These results indicate that humeral ER handling can be used for diplegic CP children rehabilitation to facilitate cervical and trunk extensor muscles activity in a GMFCS level-dependent manner. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Biomecânica de quatro técnicas de fixação da fratura em quatro partes da cabeça umeral Biomechanics of four techniques for fixation of the four-part humeral head fracture

    Directory of Open Access Journals (Sweden)

    Elpídio da Graça

    2013-02-01

    Full Text Available OBJETIVO: Realizar um estudo biomecânico de quatro técnicas de fixação das fraturas em quatro partes da cabeça umeral. MÉTODOS: A fratura foi reproduzida em 40 úmeros plásticos, divididos em grupos de dez conforme a técnica de fixação, cada uma delas empregando diferentes recursos de fixação, em configurações distintas. Os modelos umerais foram montados em uma escápula de alumínio, com tiras de couro mimetizando os tendões do capuz rotador, e submetidos a ensaios de encurvamento e de torção em uma máquina universal de ensaios, usando a rigidez relativa como parâmetro de avaliação. Montagens com o úmero intacto foram analisadas para comparação. RESULTADOS: O comportamento biomecânico das técnicas de fixação variou dentro de uma ampla faixa, as montagens incluindo a placa DCP e os parafusos de 4,5mm de diâmetro sendo significantemente mais rígidos do que as montagens com os fios de Kirschner e os parafusos 3,5 mm de diâmetro. CONCLUSÃO: As quatro técnicas foram capazes de suportar cargas compatíveis com a demanda fisiológica, mas aquelas com a maior rigidez relativa devem ser as preferidas para finalidades clínicas. Trabalho experimental.OBJECTIVE: To carry out a biomechanical study of four techniques for fixation of four-part humeral head fractures. METHODS: The fracture was reproduced in 40 plastic humeri, divided into groups of ten according to the fixation technique, each one employing different fixation resources, in different configurations. The humeral models were mounted on an aluminum scapula, with leather straps simulating the rotator cuff tendons, and submitted to bending and torsion tests in a universal testing machine, using relative stiffness as an evaluation parameter. Assemblies with intact humeri were analyzed for comparison. RESULTS: The biomechanical behavior of the fixation techniques varied within a wide range, where the assemblies including the DCP plate and the 4.5mm diameter screws

  7. The factors influencing the decision making of operative treatment for proximal humeral fractures.

    Science.gov (United States)

    Hageman, Michiel G J S; Jayakumar, Prakash; King, John D; Guitton, Thierry G; Doornberg, Job N; Ring, David

    2015-01-01

    The factors influencing the decision making of operative treatment for fractures of the proximal humerus are debated. We hypothesized that there is no difference in treatment recommendations between surgeons shown radiographs alone and those shown radiographs and patient information. Secondarily, we addressed (1) factors associated with a recommendation for operative treatment, (2) factors associated with recommendation for arthroplasty, (3) concordance with the recommendations of the treating surgeons, and (4) factors affecting the inter-rater reliability of treatment recommendations. A total of 238 surgeons of the Science of Variation Group rated 40 radiographs of patients with proximal humerus fractures. Participants were randomized to receive information about the patient and mechanism of injury. The response variables included the choice of treatment (operative vs nonoperative) and the percentage of matches with the actual treatment. Participants who received patient information recommended operative treatment less than those who received no information. The patient information that had the greatest influence on treatment recommendations included age (55%) and fracture mechanism (32%). The only other factor associated with a recommendation for operative treatment was region of practice. There was no significant difference between participants who were and were not provided with information regarding agreement with the actual treatment (operative vs nonoperative) provided by the treating surgeon. Patient information-older age in particular-is associated with a higher likelihood of recommending nonoperative treatment than radiographs alone. Clinical information did not improve agreement of the Science of Variation Group with the actual treatment or the generally poor interobserver agreement on treatment recommendations. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  8. Flexible Intramedullary Nailing for Paediatric Shaft of Femur Fractures – Does the Number of Nails Alter the Outcome?

    Directory of Open Access Journals (Sweden)

    B Kanthimathi

    2011-07-01

    Full Text Available BACKGROUND: The use of flexible intramedullary nailing, allowing micro movement at the fracture site, results in excellent outcomes regardless of the number of nails used. We undertook analysis of the outcomes of flexible nailing with reference to the number of nails used. METHODS: Twenty patients with diaphyseal femur fracture aged 5-15 years were treated with retrograde flexible intramedullary nailing. The number of nails varied from single to multiple. The results were analysed with regard to the number of nails used. RESULTS: The mean patient age was 7.9 years; patients were followed up for a mean duration of 13.2 months. Those with two and three nails had similar results. CONCLUSION: A minimum of two flexible nails is needed for optimal fixation in paediatric femur shaft fractures. Also, limiting the number of implants to two is cost effective, decreases operative time, reduces radiation exposure and offers equal results to that of three nails.

  9. Pulseless supracondylar humeral fractures in children: vascular complications in a ten year series.

    Science.gov (United States)

    Cambon-Binder, Adeline; Jehanno, Pascal; Tribout, Laurent; Valenti, Philippe; Simon, Anne-Laure; Ilharreborde, Brice; Mazda, Keyvan

    2018-04-01

    The management of pulseless supracondylar fractures remains controversial. The aims of this study were to: (1) analyse functional and vascular outcomes of conservative treatment for cases with absent pulse before reduction, whether patients showed limb ischaemia or not; and (2) identify factors associated with vascular complications. Twenty-seven children with absent pulses on presentation were treated consecutively between 1999 and 2009. The brachial artery was surgically explored in cases of persistent signs of ischaemia after reduction. Signs of vascular impairment were recorded in the early post-operative period and at a mean final follow-up of 3.5 years. Recurrent ischaemia with a compartment syndrome occurred in a patient with initial ischaemia and a pink, pulseless hand after reduction. Patients with an initially well-perfused hand and those with pre-operative ischaemia and palpable pulses after reduction had satisfactory outcomes, as did patients with early arterial exploration. No patient showed signs of chronic vascular impairment. The need for vascular repair was significantly correlated with open fracture, initial ischaemia and nerve impairment. Conservative management of supracondylar fractures with absent pulses avoided long-term vascular complications provided that patients with a pulseless, well-perfused hand on presentation were closely monitored after reduction. Further study is necessary to determine whether a forearm Doppler would help identify children with absent pulses after reduction who need surgical revascularisation due to an insufficient collateral circulation.

  10. Effect of osteosynthesis, primary hemiarthroplasty, and non-surgical management for displaced four-part fractures of the proximal humerus in elderly: a multi-centre, randomised clinical trial

    DEFF Research Database (Denmark)

    Brorson, Stig; Olsen, Bo Sanderhoff; Frich, Lars Henrik

    2009-01-01

    BACKGROUND: Fractures of the proximal humerus are common injuries and account for 4-5 percent of all fractures, second only to hip and wrist fractures. The incidence is positively correlated with age and osteoporosis, and is likely to increase. Displaced four-part fractures are among the most...... severe injuries, accounting for 2-10 percent of proximal humeral fractures. The optimal intervention is disputed. Two previous randomised trials were very small and involved a noticeable risk of bias, and systematic reviews consequently conclude that there is inadequate basis for evidence-based treatment...... ten national shoulder units within a two-year period. We plan to include 162 patients. A central randomisation unit will allocate patients. All patients will receive a standardised three-month rehabilitation program of supervised physiotherapy regardless of treatment allocation. Patients...

  11. Screw elastic intramedullary nail for the management of adult forearm fractures

    Directory of Open Access Journals (Sweden)

    Wasudeo Gadegone

    2012-01-01

    Full Text Available Background: The failure of the conventional nailing of both forearm bones or isolated fractures of radius and ulna pose a potential problem of nail migration and rotational instability, despite the best reduction. The purpose of this paper is to evaluate the results of screw elastic intramedullary nail for the treatment of adult diaphyseal fractures of both forearm bones, which effectively addresses the problems associated with the conventional nailing systems for the forearm fractures. Materials and Methods: Seventy-six adults with forearm fractures (radius and ulna or isolated fracture of the single bone were retrospectively evaluated. Fifty males and 26 females with the mean age of 38 years (range, 18-70 years underwent closed reduction and screw intramedullary nail fixation. Ten patients required limited open reduction. The fractures were classified according to the AO/OTA system. The average followup was 12 months (range, 6 to 18 months. Results: The mean surgical time was 45 minutes (35 to 65 minutes. The meantime to union was 14 weeks (10-21 weeks. The results were graded as excellent in 50, good in 18 patients, and acceptable in eight patients, using the criteria of Grace and Eversman. We had superficial infection in three cases, one case of delayed infection, painful bursa in two cases, delayed union in two cases, malunion with dislocation of the DRUJ in two cases, injury to the extensor tendon of the thumb in one case, and one case of incomplete radioulnar synostosis. Conclusion: Closed reduction and internal fixation of forearm fractures by screw intramedullary nails reestablishes the near normal relationship of the fractured fragments. Screw intramedullary nail effectively controls both rotatory forces and the migration of the nail. It produces excellent clinical results in isolated fractures of either bones, as well as both bones of the forearm in adults.

  12. [The treatment of infected diaphyseal femoral defects by lengthening one of the bone fragments by Ilizarov].

    Science.gov (United States)

    Tomić, S; Krajcinović, O; Blagojević, Z; Apostolović, M; Lalosević, V

    2006-01-01

    We analyzed 30 patients with infected diaphyseal defect of femur, which have been treated by lengthening one of the bone fragments with Ilizarov apparatus. The mean length of the bone defect was 6 cm. Substitution of the defect, bone healing and elimination of the infection was achieved in 27 patients. The mean time of apparatus fixation was 10 months. According to Palley scoring system, 10 patients had excellent functional results.

  13. Effective management of bone fractures with the IlluminOss® photodynamic bone stabilization system: initial clinical experience from the European Union registry

    Directory of Open Access Journals (Sweden)

    Thomas Gausepohl

    2017-02-01

    Full Text Available The IlluminOss® system (IS uses a light-curable polymer contained within an inflatable balloon catheter, forming a patient customized intramedullary implant. A registry was established in Germany and The Netherlands to prospectively collect technical and clinical outcomes in patients treated with IS for fractures of the phalange, metacarpal, radius, ulna, distal radius, fibula, clavicle and/or olecranon. Humeral, femoral, tibial and pelvic fractures were included under compassionate use. Procedural success included successful placement of the device at the target fracture site and achievement of fracture stabilization. Clinical and radiographic assessments were made postoperatively through 12 months. One hundred thirty two patients (149 fractures were enrolled with most fractures (85% resulting from low-energy trauma. Simple fractures predominated (47% followed by complex (23% and wedge (16% fractures. Procedural success was achieved in all patients and no implants required removal or revision. Normal range of motion was realized in 87% of fractures. Radiographically, there was substantial cortical bridging, total dissolution of the fracture line, and complete fracture healing. Across a variety of fracture types, the IS provides a safe and effective approach for rapid healing and functional recovery.

  14. Effectiveness of a step-by-step oral recount before a practical simulation of fracture fixation.

    Science.gov (United States)

    Abagge, Marcelo; Uliana, Christiano Saliba; Fischer, Sergei Taggesell; Kojima, Kodi Edson

    2017-10-01

    To evaluate the effectiveness of a step-by-step oral recount by residents before the final execution of a practical exercise simulating a surgical fixation of a radial diaphyseal fracture. The study included 10 residents of orthopaedics and traumatology (four second- year and six first-year residents) divided into two groups with five residents each. All participants initially gathered in a room in which a video was presented demonstrating the practical exercise to be performed. One group (Group A) was referred directly to the practical exercise room. The other group (Group B) attended an extra session before the practical exercise, in which they were invited by instructors to recount all the steps that they would perform during the practical exercise. During this session, the instructors corrected the residents if any errors in the step-by-step recount were identified, and clarified questions from them. After this session, both Groups A and B gathered in a room in which they proceeded to the practical exercise, while being video recorded and evaluated using a 20-point checklist. Group A achieved a 57% accuracy, with results in this group ranging from 7 to 15 points out of a total of a possible 20 points. Group B achieved an 89% accuracy, with results in this group ranging from 15 to 20 points out of 20. An oral step-by-step recount by the residents before the final execution of a practical simulation exercise of surgical fixation of a diaphyseal radial fracture improved the technique and reduced the execution time of the exercise. © 2017 Elsevier Ltd. All rights reserved.

  15. Slow Recovery of Weight Bearing After Stabilization of Long-Bone Fractures Using Elastic Stable Intramedullary Nails in Children.

    Science.gov (United States)

    Lardelli, Patrizia; Frech-Dörfler, Martina; Holland-Cunz, Stefan; Mayr, Johannes

    2016-03-01

    Stabilization of diaphyseal long-bone fractures using elastic stable intramedullary nails (ESIN) in children promises early mobilization and rapid resumption of full weight bearing. We evaluated the duration of postoperative functional rehabilitation after ESIN, measured by the time from stabilization until first partial weight bearing, full weight bearing, and resumption of school sports. Fifty children with unstable, displaced fractures of the femur or lower leg treated with ESIN between 2002 and 2012 were included in this retrospective analysis. We classified fractures according to the pediatric comprehensive classification of fractures (PCCF). Thirty-five children sustained a femur fracture, and 15 children had a fracture of the lower leg or tibia. The surgeons in charge applied an additional plaster cast in 7 of 15 children who suffered a lower leg fracture. The postoperative time interval until full weight bearing in the group of children who had suffered transverse or short oblique femur fractures was significantly shorter (median: 4.4 weeks; range: 0.1-9.1 weeks) than that in the group who had sustained more complex fracture patterns (median: 6.8 weeks; range: 2.9-13.9 weeks; P = 0.04). Similarly, transverse and short oblique lower leg and tibia fractures required less time until full weight bearing (median: 4.1 weeks; range 2.7-6.0 weeks) than complex lower leg fractures (median: 6.1 weeks; range: 1.3-12.9 weeks; P = 0.04). ESIN proved fairly effective in restoring full weight bearing in transverse or short oblique fractures of the lower extremities but was less effective in complex fractures.

  16. Fracture risk in unicameral bone cyst. Is magnetic resonance imaging a better predictor than plain radiography?

    Science.gov (United States)

    Pireau, Nathalie; De Gheldere, Antoine; Mainard-Simard, Laurence; Lascombes, Pierre; Docquier, Pierre-Louis

    2011-04-01

    The classical indication for treating a simple bone cyst is usually the risk of fracture, which can be predicted based on three parameters: the bone cyst index, the bone cyst diameter, and the minimal cortical thickness. A retrospective review was carried out based on imaging of 35 simple bone cysts (30 humeral and 5 femoral). The three parameters were measured on standard radiographs, and on T1-weighted and T2-weighted MRI. The measurements were performed by two independent reviewers, and twice by the same reviewer. Kappa values and binary logistic regression were used to assess the ability of the parameters to predict the fracture risk. Inter- and intra-observer agreement was measured. T1-weighted MRI was found to have the best inter- and intraobserver repeatability. The bone cyst index was found to be the best predictor for the risk of fracture.

  17. Expression of TGF-β in Fractures Fixed by Nitinol Swan-like Memory Compressive Connectors

    Science.gov (United States)

    Li, M.; Zhang, C. C.; Xu, S. G.; Fu, Q. G.

    2011-07-01

    In this article, the effect of internal fixation of a Nitinol swan-like memory compressive connector (SMC) on the temporal expression of transforming growth factor-β (TGF-β) at fracture sites is evaluated. Specimens were collected from 35 New Zealand rabbits modeled for bilateral humeral fracture fixed with either SMC or stainless dynamic compression plate (DCP). Five rabbits each were killed at day 1, 3, 7, 14, 21, 28, and 56. The local positive staining potency, positive area ratio, and positive index of TGF-β were measured using an immunohistochemistry approach (EnVision) in combination with a computerized image analysis system. TGF-β staining was seen in mesenchymal cells, osteoblasts, chondrocytes, and in the extracellular matrix of fractures fixed in both the SMC and the DCP samples without a significant difference in staining at both the early stages (days 1 and 3) and day 56. A higher TGF-β content was observed in the fractures fixed with SMC when compared to that of DCP from day 7 to 28. As a conclusion, TGF-β is highly expressed in fractures fixed with SMC during chondrogenesis stage and entochondrostosis stage. Finally, the mechanism of how SMC promoting synthesis and secretion of TGF-β in the process of fracture healing has been discussed.

  18. A STUDY OF THE MANAGEMENT OF OPEN FRACTURES OF TIBIA BY UNREAMED INTERLOCKING NAIL

    Directory of Open Access Journals (Sweden)

    Kuppa Srinivas

    2015-01-01

    Full Text Available AIMS AND OBJECTIVES: To evaluate the results of closed interlocking intramedullary nailing without reaming in the treatment of open fractures of t he tibial shaft and study the difficulties (complications encountered during the operative study. To compare the efficacy of interlocking intramedullary nailing without reaming in treating open fractures of tibia, Time required for the union of fracture, Range of motion of ankle and knee joint, Rate of malunion and mal rotation and Pain at the knee joint. RESULTS: The average age of patient is 32 years,83.33% are males, road traffic accidents account for majority(79.16%,right side involved in 58.33%,gustillo type II and type I compound fractures are common, full range of movements is seen in 66.67% by 12 weeks and union occurred in 95.83% by 9 months. Thirteen (54.17% patients had excellent results, six (25% patients had good results, four (1 6.67% patients had fair results and one (4.16 patient had poor result. CONCLUSION: Unreamed interlocking intramedullary nailing with the help of image intensifier seems feasible in open diaphyseal fractures of tibia with the advantages of minimal blood l oss, low risk of infection, early mobilisation , earlier soft tissue coverage , Promotes early union , minimal hospital stay and early returns to activities

  19. Retrospective analysis of extra-articular distal humerus shaft fractures treated with the use of pre-contoured lateral column metaphyseal LCP by triceps-sparing posterolateral approach

    Directory of Open Access Journals (Sweden)

    Yatinder Kharbanda

    2016-11-01

    Full Text Available Abstract Management of extra-articular distal humerus fractures presents a challenge to the treating surgeon due to the complex anatomy of the distal part of the humerus and complicated fracture morphology. Although surgical treatment has shown to provide a more stable reduction and alignment and predictable return to function, it has been associated with complications like iatrogenic radial nerve palsy, infection, non-union and Implant failure. We in the present series retrospectively analysed 20 patients with extra-articular distal humerus shaft fractures surgically treated using the extra-articular distal humeral locking plate approached by the triceps-sparing posterolateral approach. The outcome was assessed using the DASH score, range of motion at the elbow and the time to union. The mean time to radiographic fracture union was 12 weeks.

  20. Retrospective analysis of extra-articular distal humerus shaft fractures treated with the use of pre-contoured lateral column metaphyseal LCP by triceps-sparing posterolateral approach.

    Science.gov (United States)

    Kharbanda, Yatinder; Tanwar, Yashwant Singh; Srivastava, Vishal; Birla, Vikas; Rajput, Ashok; Pandit, Ramsagar

    2017-04-01

    Management of extra-articular distal humerus fractures presents a challenge to the treating surgeon due to the complex anatomy of the distal part of the humerus and complicated fracture morphology. Although surgical treatment has shown to provide a more stable reduction and alignment and predictable return to function, it has been associated with complications like iatrogenic radial nerve palsy, infection, non-union and Implant failure. We in the present series retrospectively analysed 20 patients with extra-articular distal humerus shaft fractures surgically treated using the extra-articular distal humeral locking plate approached by the triceps-sparing posterolateral approach. The outcome was assessed using the DASH score, range of motion at the elbow and the time to union. The mean time to radiographic fracture union was 12 weeks.

  1. Radiographic evaluation of the canine elbow joint with special reference to the medial humeral condyle and the medial coronoid process

    International Nuclear Information System (INIS)

    Voorhout, G.; Hazewinkel, H.A.W.

    1987-01-01

    The results of radiographic examination of clinically affected elbow joints in 14 young, large-breed dogs, including standard and oblique projections and linear tomography, were compared with the findings of medial arthrotomy. Radiographs revealed arthrosis (13 dogs), osteochondrosis of the medial humeral condyle (2 dogs), fragmentation of the medial coronoid process (5 dogs), and a combination of osteochondrosis of the medial humeral condyle and fragmentation of the medial coronoid process (2 dogs). In one dog fissures in the medial coronoid process and in another dog a linear radiopacity along the articular surface of the medial coronoid process were found. In three dogs both medial humeral condyle and medial coronoid process appeared normal. The radiographic findings were confirmed during surgery in 11 dogs. Cartilage erosion of the medial humeral condyle in two dogs and of the medial coronoid process in one dog had not resulted in radiographically visible abnormalities. Radiographic examination of the elbow joints in young, large-breed dogs should include standard mediolateral and craniocaudal projections, a mediolateral projection with the joint maximally extended and the leg supinated 15°, and a craniolateral-to-caudomedial projection

  2. Stress fractures of the humerus, radius, and tibia in horses: clinical features and radiographic and/or scintigraphic appearance

    International Nuclear Information System (INIS)

    Mackey, V.S.; Trout, D.R.; Meagher, D.M.; Hornof, W.J.

    1987-01-01

    The medical records, radiographic and nuclear scintigraphic findings of 26 racing horses with 27 stress fracture episodes of the humerus, radius, or tibia were reviewed. The purposes of this study were to describe the radiographic and/or scintigraphic features of stress fractures of the humerus, radius, or tibia, and to evaluate the signalment and history of horses in which stress fracture occurred. Stress fractures of the three long bones examined were primarily seen in 2- and 3-year-old male Thoroughbred horses; commonly, the onset of lameness was immediately following training gallops or racing. There were 13 humeral stress fracture episodes in 12 horses. Ten were in the proximal caudolateral cortex, and three were in the distal craniomedial cortex. Radical stress fractures were seen in three horses, all in the midshaft radius. Tibial stress fractures were diagnosed in 11 horses. They were located in the proximal lateral tibia in six horses, the distal caudolateral tibia in three horses, and the midshaft tibia in three horses. Fifteen stress fractures were diagnosed with radiography alone, one was diagnosed with scintigraphy alone, nine were diagnosed with radiographs and scintigraphy, and, in two horses, radiographs were negative, but the scintigraphic findings were consistent with stress fracture

  3. The changing epidemiology of open fractures in vehicle occupants, pedestrians, motorcyclists and cyclists.

    Science.gov (United States)

    Winkler, Dennis; Goudie, Stuart T; Court-Brown, Charles M

    2018-02-01

    To investigate the changing epidemiology of open fractures in vehicle occupants, pedestrians, motorcyclists and cyclists. Data on all non-spinal open fractures admitted to the Royal Infirmary of Edinburgh after a road traffic accident between 1988 and 2010 were collected and analysed to provide information about the changing epidemiology in different patient groups. Demographic information was collected on all patients with the severity of injury being analysed with the Injury Severity Score (ISS), Musculoskeletal Index (MSI) and the number of open fractures. The severity of the open fractures was analysed using the Gustilo classification. The 23-year study period was divided into four shorter periods and the results were compared. There were 696 patients treated in 23 years. Analysis showed that the incidence of RTA open fractures initially fell in both males and females and continued to fall in females during the 23 years. In males it levelled off about 2000. The age of the female patients also fell during the study period but it did not change in males. The only patient group to show an increased incidence of open fractures were cyclists. In vehicle occupants the incidence fell throughout the study period but it levelled off in pedestrians and motorcyclists. There was no difference in the severity of injury in any group during the study period. The most severe open fractures were those of the distal femur and femoral diaphysis although open tibial diaphyseal fractures were the most common fracture in all patient groups. Improved car design and road safety legislation has resulted in a reduction in the incidence of open fractures in vehicle occupants, pedestrians and motorcyclists. The most obvious group to have benefitted from this are older female pedestrians. The only group to show an increase in age during the study period were male motorcyclists. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. To evaluate the role of platelet-rich plasma in healing of acute diaphyseal fractures of the femur

    Directory of Open Access Journals (Sweden)

    Roop Singh

    2017-02-01

    Conclusion: PRP has no effect on femoral shaft fracture healing treated with closed intramedullary nailing. However, PRP and matrix scaffold provided by fibrin membrane may provide an artificial hematoma effect in the initial phase of healing in open or failed closed intramedullary nailing.

  5. A Removable Long-arm Soft Cast to Treat Nondisplaced Pediatric Elbow Fractures: A Randomized, Controlled Trial.

    Science.gov (United States)

    Silva, Mauricio; Sadlik, Gal; Avoian, Tigran; Ebramzadeh, Edward

    2018-04-01

    The ideal type of immobilization for nondisplaced pediatric elbow fractures has not been established. We hypothesized that the use of a long-arm cylinder made of soft cast material will result in similar outcomes to those obtained with a traditional long-arm hard cast. We randomly assigned 100 consecutive children who presented with a closed, nondisplaced, type I supracondylar humeral fracture or an occult, closed, acute elbow injury, to 1 of 2 groups: group A (n=50) received a long-arm, traditional fiberglass (hard) cast. Group B (n=50) received a long-arm, soft fiberglass cast. After 4 weeks, the cast was removed in group A by a member of our staff using a cast saw, and in group B by one of the patient's parents by rolling back the soft fiberglass material. We compared the amount of fracture displacement and/or angulation, recovery of range of motion, elbow pain, and patient satisfaction. There were no instances of unplanned removal of the cast by the patient or parent. No evidence of fracture displacement or angulation was seen in either group. The final carrying angle of the affected elbow was nearly identical of that of the normal, contralateral elbow in both groups (P=0.64). At the latest follow-up appointment, elbows in groups A and B had a similar mean arc of motion (156 vs. 154 degrees; P=0.45), and had achieved identical relative arc of motion of 99.6% and 99.5% of that of the normal, contralateral side, respectively (P=0.94). Main pain scores were low and comparable over the study period. All patients in both groups reported the highest rate of satisfaction at the eighth week of follow-up. The results indicate that children with nondisplaced supracondylar humeral fractures can be successfully managed with the use of a removable long-arm soft cast, maintaining fracture alignment and resulting in comparable rates of range of motion, pain, and patient satisfaction. The use of a removable immobilization that can reliably maintain fracture alignment and

  6. Evaluation of transfixation casting for treatment of third metacarpal, third metatarsal, and phalangeal fractures in horses: 37 cases (1994-2004).

    Science.gov (United States)

    Lescun, Timothy B; McClure, Scott R; Ward, Michael P; Downs, Christopher; Wilson, David A; Adams, Stephen B; Hawkins, Jan F; Reinertson, Eric L

    2007-05-01

    To evaluate clinical findings, complications, and outcome of horses and foals with third metacarpal, third metatarsal, or phalangeal fractures that were treated with transfixation casting. Retrospective case series. Animals-29 adult horses and 8 foals with fractures of the third metacarpal or metatarsal bone or the proximal or middle phalanx. Medical records were reviewed, and follow-up information was obtained. Data were analyzed by use of logistic regression models for survival, fracture healing, return to intended use, pin loosening, pin hole lysis, and complications associated with pins. In 27 of 35 (77%) horses, the fracture healed and the horse survived, including 10 of 15 third metacarpal or metatarsal bone fractures, 11 of 12 proximal phalanx fractures, and 6 of 8 middle phalanx fractures. Four adult horses sustained a fracture through a pin hole. One horse sustained a pathologic unicortical fracture secondary to a pin hole infec-tion. Increasing body weight, fracture involving 2 joints, nondiaphyseal fracture location, and increasing duration until radiographic union were associated with horses not returning to their intended use. After adjusting for body weight, pin loosening was associated with di-aphyseal pin location, pin hole lysis was associated with number of days with a transfixation cast, and pin complications were associated with hand insertion of pins. Results indicated that transfixation casting can be successful in managing fractures distal to the carpus or tarsus in horses. This technique is most suitable for comminuted fractures of the proximal phalanx but can be used for third metacarpal, third metatarsal, or middle phalanx fractures, with or without internal fixation.

  7. [Kirschner wire osteosynthesis for fractures in childhood: bury wires or not? : Results of a survey on care reality in Germany].

    Science.gov (United States)

    Schneidmueller, D; Kertai, M; Bühren, V; von Rüden, C

    2018-02-20

    Kirschner wire osteosynthesis is considered to be the standard technique for surgical fixation of displaced supracondylar humeral and distal radial fractures in children. The Kirschner wires can be left exposed or buried under the skin. Advantages of the epicutaneous technique are, e. g. the efficiency (cost, effort) and the possibility for wire removal without the necessity of a second anesthesia. On the other hand, there is a concern about higher infection rates as well as traumatization of the children due to externally visible wires. A web-based survey of members of the DGU, DGOU, DGOOC, and the pediatric traumatology section of the DGU (SKT) was performed to evaluate current treatment concepts in Germany. The pros and cons for each technique were recorded and the need for a clinical study was examined. In addition, a cost analysis was performed for both methods. The results from the literature are summarized and discussed. A total of 710 questionnaires were evaluated. The majority of the respondents were trauma surgeons working in a hospital (80%). The buried technique was superior in both fracture groups (supracondylar humeral fractures 73% and distal radius fractures 69%), whereas a relevant difference could be found depending on the profession. The main reason for the subcutaneous technique was anxiety or observed higher infections using the epicutaneous technique. In Germany, the majority of wires are buried under the skin due to a fear of higher infection rates. In addition, other influencing factors such as pain and traditional approaches play a significant role. With respect to the results in the literature as well as a possible improvement of efficiency and avoidance of a second anesthesia, a multicentric clinical study seems necessary in the future to compare both techniques.

  8. Atypical subtrochanteric and diaphyseal femoral fractures: report of a task force of the American Society for Bone and Mineral Research

    DEFF Research Database (Denmark)

    Shane, Elizabeth; Burr, David; Ebeling, Peter R

    2010-01-01

    Reports linking long-term use of bisphosphonates (BPs) with atypical fractures of the femur led the leadership of the American Society for Bone and Mineral Research (ASBMR) to appoint a task force to address key questions related to this problem. A multidisciplinary expert group reviewed pertinent...... to designate a femoral fracture as atypical. Minor features include their association with cortical thickening, a periosteal reaction of the lateral cortex, prodromal pain, bilaterality, delayed healing, comorbid conditions, and concomitant drug exposures, including BPs, other antiresorptive agents...... published reports concerning atypical femur fractures, as well as preclinical studies that could provide insight into their pathogenesis. A case definition was developed so that subsequent studies report on the same condition. The task force defined major and minor features of complete and incomplete...

  9. MR imaging findings of fatigue fractures of lower extremity in young soldiers

    International Nuclear Information System (INIS)

    Mo, Jong Hyun; Moon, Sung Hee; Kim, Young Bok; Park, Yang Hee; Park, Jin Kyoon

    1999-01-01

    To evaluate the MR imaging findings of fatigue fractures of the lower extremity in young soldiers. In 22 cases of fatigue fractures of the lower extremity in young soldiers proven by clinical findings and radiological follow up, the MRI findings were retrospectively evalvated. All patients were male and aged between 19 and 21 years. As seen on MRI, the bone marrow edema, intramedullary low signal intensity band, cortical fracture line, periosteal reaction, surrounding soft tissue edema, and enhancement pattern were analyzed and the site of involvement was determined in the axial plane. The locations of fatigue fractures of the lower extremity were the tibia (n=12), fibula (n=8), femur (n=1) and second metatarsus (n=1). All occurred in diaphyses: the junction of the proximal and middle (n=10), middle (n=9), proximal (n=2), and distal shaft (n=1). The sites of involvement were the posteromedial (n=6) and medial side (n=6) of the tibia, and the entire portion of the fibula(n=5) in the axial plane. MRI findings were bone marrow edema in 20 cases, intramedullary low signal intensity band in 14 (which were continuous with the cortex or cortical fracture line), cortical fracture line in 13, and periosteal reaction and surrounding soft tissue edema in all. On gadolinium-enhanced images, enhancement was seen in the bone marrow in 19 cases, in the subperiosteal region in 18, and in the surrounding soft tissue in 22. In fatigue fractures of the lower extremity in young soldiers, the main locations were the tibia and fibula, and characteristic MR imaging findings were intramedullary low signal intensity bands, which were continuous with the cortex or cortical fracture line and often accompanied by bone marrow edema, periosteal reaction, and surrounding soft tissue edema

  10. Reduced diaphyseal strength associated with high intracortical vascular porosity within long bones of children with osteogenesis imperfecta.

    Science.gov (United States)

    Albert, Carolyne; Jameson, John; Smith, Peter; Harris, Gerald

    2014-09-01

    Osteogenesis imperfecta is a genetic disorder resulting in bone fragility. The mechanisms behind this fragility are not well understood. In addition to characteristic bone mass deficiencies, research suggests that bone material properties are compromised in individuals with this disorder. However, little data exists regarding bone properties beyond the microstructural scale in individuals with this disorder. Specimens were obtained from long bone diaphyses of nine children with osteogenesis imperfecta during routine osteotomy procedures. Small rectangular beams, oriented longitudinally and transversely to the diaphyseal axis, were machined from these specimens and elastic modulus, yield strength, and maximum strength were measured in three-point bending. Intracortical vascular porosity, bone volume fraction, osteocyte lacuna density, and volumetric tissue mineral density were determined by synchrotron micro-computed tomography, and relationships among these mechanical properties and structural parameters were explored. Modulus and strength were on average 64-68% lower in the transverse vs. longitudinal beams (Posteogenesis imperfecta. Results confirm that these properties are anisotropic. Elevated vascular porosity was observed in most specimens, and this parameter was associated with reduced bone material strength. These results offer insight toward understanding bone fragility and the role of intracortical porosity on the strength of bone tissue in children with osteogenesis imperfecta. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Surgical management of complete diaphyseal third metacarpal and metatarsal bone fractures: Clinical outcome in 10 mature horses and 11 foals

    OpenAIRE

    Bischofberger, Andrea S; Fürst, Anton; Auer, Jörg A; Lischer, Christoph J

    2009-01-01

    Reasons for performing study: Osteosynthesis of third metacarpal (McIII) and third metatarsal (MtIII) bone fractures in horses is a surgical challenge and complications surrounding the repair are common. Retrospective studies evaluating surgical repair, complications and outcome are necessary to increase knowledge and improve success of long bone fracture repair in the horse. Objectives: To evaluate clinical findings, surgical repair, post operative complications and outcome of 10 mature h...

  12. Seat belt syndrome with unstable Chance fracture dislocation of the second lumbar vertebra without neurological deficits.

    Science.gov (United States)

    Onu, David O; Hunn, Andrew W; Bohmer, Robert D

    2014-01-08

    The seat belt syndrome is a recognised complication of seat belt use in vehicles. Unstable Chance fractures of the spine without neurological deficits have been reported infrequently. We describe a young woman with completely disrupted Chance fracture of the second lumbar vertebra in association with left hemidiaphragmatic rupture/hernia, multiple bowel perforations, splenic capsular tear, left humeral shaft and multiple rib fractures. These injuries which resulted from high-speed vehicle collision and led to death of one of the occupants were readily detected by trauma series imaging. The patient was successfully treated by a dedicated multidisciplinary team which adopted a staged surgical approach and prioritisation of care. There were no manifested neurological or other deficits after 1 year of follow-up. To the authors' knowledge, this is the first report of such a case in Australasia. We discuss the challenging surgical management, highlighting the role of radiological imaging in such cases and provide a literature review.

  13. A Limb-Threatening Long Arterial Dissection Caused by Humerus Neck Fracture: A Case Report

    Directory of Open Access Journals (Sweden)

    Kurnaz R

    2018-03-01

    Full Text Available Proximal humerus fracture is a common arm trauma and rarely occurs with vascular injury which however is a serious complication. In this case report, we present a long segment dissection of the axillary and brachial arteries as a rare complication due to fragmented proximal humerus fracture and shoulder dislocation. An 80-year old female patient was seen at the emergency department. Radiograph examination has revealed a fragmented proximal humerus fracture besides dislocation of the head of humerus towards the axillary area. On vascular examination, acute arterial occlusion such as absence of radial and ulnar pulses were observed in her left hand. The patient was immediately taken to the operating room. The dissection included the entire segment approximately 20cm between the distal subclavian artery and the distal brachial artery. This injured segment was removed and a 6mm Polytetrafluroethylene (PTFE graft with rings was interpositoned between subclavian and brachial arteries. This case is a rarity because of such a significant complication after a small injury. Axillary artery injuries caused by humeral neck fractures are rare but should not be missed by the physician.

  14. Early results for treatment of two- and three-part fractures of the proximal humerus using Contours PHP (proximal humeral plate).

    Science.gov (United States)

    Biazzo, Alessio; Cardile, Carlo; Brunelli, Luca; Ragni, Paolo; Clementi, Daniele

    2017-04-28

    The management of displaced 2- and 3-part fractures of the proximal humerus is controversial, both in younger and in elderly patients. The purpose of this paper is to evaluate the functional results of the Contours Proximal Humerus Plate (OrthofixR, Bussolengo,Verona, Italy), for the treatment of displaced 2- and 3-part fractures of the proximal humerus. We retrospectively reviewed 55 patients with proximal humerus fractures, who underwent osteosynthesis with Contours Proximal Humerus Plate from December 2011 to March 2015. We had 21 patients with 2-part fractures and with an average age of 67.1 years and 34 patients with 3-part fractures, with average age of 63.6 years. The average union time was 3 months. The mean Constant score was 67 for 2-part fracture group and 64.9 for 3-part fracture group. The difference was not statistically significant (p = 0.18). The overall complication rate was 14.5 %. Six patients underwent additional surgery (10.9%). The most frequent major complication was secondary loss of reduction following varus collapse of the fracture (2 cases). In these patients, there was loss of medial hinge integrity due to impaction and osteoporosis. The placement of the main locking screw in the calcar area to provide inferomedial support is the rational of the Contours Proximal Humerus Plate. Osteosynthesis with Contours Proximal Humerus Plate is a safe system for treating displaced 2- and 3-part fractures of the proximal humerus, with good functional results and complication rates comparable to those reported in the literature.

  15. Estudo epidemiológico das fraturas femorais diafisárias pediátricas Epidemiological study of children diaphyseal femoral fractures

    Directory of Open Access Journals (Sweden)

    Cassiano Ricardo Hoffmann

    2012-04-01

    Full Text Available OBJETIVO: Avaliar as características pessoais, das fraturas e do tratamento e suas complicações em pacientes com fraturas femorais diafisárias pediátricas atendidos no Serviço de Ortopedia Pediátrica do Hospital Infantil Joana de Gusmão. MÉTODOS: Trata-se de estudo retrospectivo e transversal com população composta por pacientes com fraturas diafisárias de fêmur, com idade entre o nascimento e 14 anos e 11 meses, divididos em quatro grupos etários. As informações foram obtidas nos prontuários e transferidas para o questionário de pesquisa que apresentava variáveis pessoais, das fraturas e do tratamento e suas complicações. RESULTADOS: A população do estudo foi composta por 96 pacientes. A média de idade encontrada foi de 6,8 anos. Houve predomínio no sexo masculino, fratura fechada, lado direito, 1/3 médio e traço simples. Quanto à etiologia das fraturas, houve predomínio na amostra global de acidentes de trânsito. A maioria dos pacientes (74-77,1% apresentou fratura de fêmur como lesão isolada. Houve predomínio do tratamento conservador na faixa etária menor que seis anos e do tratamento cirúrgico na faixa etária de seis anos a 14 anos e 11 meses. As complicações observadas até a união óssea foram: discrepância, infecção e limitação de movimento. O tempo médio de consolidação foi de 9,6 ± 2,4 semanas, variando com a idade. CONCLUSÃO: As características das fraturas estudadas foram semelhantes às citadas na literatura e o tratamento empregado apresentou bom resultado. O Hospital Infantil Joana de Gusmão (HIJG tem utilizado o tratamento proposto pela literatura nas fraturas femorais diafisárias pediátricas.OBJECTIVE: To evaluate the personal, fracture, treatment and complication characteristics among patients with pediatric femoral shaft fractures attended at the pediatric orthopedic service of the Joana de Gusmão Children's Hospital. METHODS: This was a retrospective cross-sectional study

  16. Percutaneous locking plates for fractures of the distal tibia: our experience and a review of the literature.

    Science.gov (United States)

    Ahmad, Mudussar Abrar; Sivaraman, Alagappan; Zia, Ahmed; Rai, Amarjit; Patel, Amratlal D

    2012-02-01

    Distal tibial metaphyseal fractures pose many complexities. This study assessed the outcomes of distal tibial fractures treated with medial locking plates. Eighteen patients were selected based on the fracture pattern and classified using the AO classification and stabilized with an AO medial tibial locking plate. Time to fracture union, complications, and outcomes were assessed with the American Orthopedic Foot and Ankle Society Ankle score at 12 months. Sixteen of the 18 patients achieved fracture union, with 1 patient lost to follow-up. Twelve fractures united within 24 weeks, with an average union time of 23.1 weeks. Three delayed unions, two at 28 weeks and one at 56 weeks. The average time to union was 32 weeks in the smokers and 15.3 weeks in the nonsmokers. Five of the 18 patients (27%) developed complications. One superficial wound infection, and one chronic wound infection, resulting in nonunion at 56 weeks, requiring revision. Two patients required plate removal, one after sustaining an open fracture at the proximal end of the plate 6 months after surgery (postfracture union)and the other for painful hardware. One patient had implant failure of three proximal diaphyseal locking screws at the screwhead/neck junction, but successful fracture union. The average American Orthopedic Foot and Ankle Society ankle score was 88.8 overall, and 92.1 in fractures that united within 24 weeks. Distal tibial locking plates have high fracture union rates, minimum soft tissue complications, and good functional outcomes. The literature shows similar fracture union and complication rates in locking and nonlocking plates. Copyright © 2012 by Lippincott Williams & Wilkins

  17. Modification of elastic stable intramedullary nailing with a 3rd nail in a femoral spiral fracture model - results of biomechanical testing and a prospective clinical study.

    Science.gov (United States)

    Kaiser, Martin M; Stratmann, Christine; Zachert, Gregor; Schulze-Hessing, Maaike; Gros, Nina; Eggert, Rebecca; Rapp, Marion

    2014-01-08

    Elastic stable intramedullary nailing (ESIN) is the standard treatment for displaced diaphyseal femoral fractures in children. However, high complication rates (10-50%) are reported in complex fractures. This biomechanical study compares the stiffness with a 3rd nail implanted to that in the classical 2C-shaped configuration and presents the application into clinical practice. For each of the 3 configurations of ESIN-osteosynthesis with titanium nails eight composite femoral grafts (Sawbones®) with an identical spiral fracture were used: 2C configuration (2C-shaped nails, 2 × 3.5 mm), 3CM configuration (3rd nail from medial) and 3CL configuration (3rd nail from lateral). Each group underwent biomechanical testing in 4-point bending, internal/external rotation and axial compression. 2C and 3CM configurations showed no significant differences in this spiroid type fracture model. 3CL had a significantly higher stiffness during anterior-posterior bending, internal rotation and 9° compression than 2C, and was stiffer in the lateral-medial direction than 3CM. The 3CL was less stable during p-a bending and external rotation than both the others. As biomechanical testing showed a higher stability for the 3CL configuration in two (a-p corresponding to recurvation and 9° compression to shortening) of three directions associated with the most important clinical problems, we added a 3rd nail in ESIN-osteosynthesis for femoral fractures. 11 boys and 6 girls (2.5-15 years) were treated with modified ESIN of whom 12 were '3CL'; due to the individual character of the fractures 4 patients were treated with '3CM' (third nail from medial) and as an exception 1 adolescent with 4 nails and one boy with plate osteosynthesis. No additional stabilizations or re-operations were necessary. All patients achieved full points in the Harris-Score at follow-up; no limb length discrepancy occurred. The 3CL configuration provided a significantly higher stiffness than 2C and 3CM configurations

  18. Management of proximal humeral fractures in the nineteenth century: an historical review of preradiographic sources

    DEFF Research Database (Denmark)

    Brorson, Stig

    2011-01-01

    The diagnosis and treatment of fractures of the proximal humerus have troubled patients and medical practitioners since antiquity. Preradiographic diagnosis relied on surface anatomy, pain localization, crepitus, and impaired function. During the nineteenth century, a more thorough understanding...

  19. Risks of all-cause and site-specific fractures among hospitalized patients with COPD

    Science.gov (United States)

    Liao, Kuang-Ming; Liang, Fu-Wen; Li, Chung-Yi

    2016-01-01

    Abstract Patients with chronic obstructive pulmonary disease (COPD) have a high prevalence of osteoporosis. The clinical sequel of osteoporosis is fracture. Patients with COPD who experience a fracture also have increased morbidity and mortality. Currently, the types of all-cause and site-specific fracture among patients with COPD are unknown. Thus, we elucidated the all-cause and site-specific fractures among patients with COPD. A retrospective, population-based, cohort study was conducted utilizing the Taiwan Longitudinal Health Insurance Database. Patients with COPD were defined as those who were hospitalized with an International Classification of Diseases, Ninth Revision, Clinical Modification code of 490 to 492 or 496 between 2001 and 2011. The index date was set as the date of discharge. The study patients were followed from the index date to the date when they sought care for any type of fracture, date of death, date of health insurance policy termination, or the last day of 2013. The types of fracture analyzed in this study included vertebral, rib, humeral, radial and ulnar/wrist, pelvic, femoral, and tibial and fibular fractures. The cohort consisted of 11,312 patients with COPD. Among these patients, 1944 experienced fractures. The most common site-specific fractures were vertebral, femoral, rib, and forearm fractures (radius, ulna, and wrist) at 32.4%, 31%, 12%, and 11.8%, respectively. The adjusted hazard ratios of fracture were 1.71 [95% confidence interval (95% CI) = 1.56–1.87] for female patient with COPD and 1.50 (95% CI = 1.39–1.52) for patients with osteoporosis after covariate adjustment. Vertebral and hip fractures are common among patients with COPD, especially among males with COPD. Many comorbidities contribute to the high risk of fracture among patients with COPD. PMID:27749576

  20. Little Leaguer's shoulder (proximal humeral epiphysiolysis): MRI findings in four boys

    International Nuclear Information System (INIS)

    Obembe, Olufolajimi O.; Gaskin, Cree M.; Anderson, Mark W.; Taffoni, Matthew J.

    2007-01-01

    Shoulder pain is a common problem among adolescent athletes. A possible cause of such pain that can be diagnosed on MRI is a stress injury to the proximal humerus known as Little Leaguer's shoulder (proximal humeral epiphysiolysis). Our objective was to describe the MRI appearance of Little Leaguer's shoulder. Four patients (all boys; age range 11-15 years; median 13 years) with clinical, plain radiographic, and MR imaging findings of Little Leaguer's shoulder were studied retrospectively. MRI demonstrated focal physeal widening in all four boys with extension of physeal signal intensity into the metaphysis on T1-weighted and gradient echo coronal and sagittal sequences. T2-weighted sequences were of limited use in demonstrating the physeal widening, which is critical to the diagnosis. Abnormal high T2-signal intensity was seen in the metaphysis adjacent to the focal physeal widening in all the boys. Focal extension of normal physeal T1-weighted and gradient echo signal intensity into the adjacent metaphysis is a sign of stress injury in the proximal humeral physis (Little Leaguer's shoulder). Children should suspend the offending sport to allow healing. (orig.)

  1. Return to sports after stress fractures of the tibial diaphysis: a systematic review.

    Science.gov (United States)

    Robertson, G A J; Wood, A M

    2015-06-01

    This review aims to provide information on the time taken to resume sport following tibial diaphyseal stress fractures (TDSFs). A systematic search of Medline, EMBASE, CINHAL, Cochrane, Web of Science, PEDro, Sports Discus, Scopus and Google Scholar was performed using the keywords 'tibial', 'tibia', 'stress', 'fractures', 'athletes', 'sports', 'non-operative', 'conservative', 'operative' and 'return to sport'. Twenty-seven studies were included: 16 reported specifically on anterior TDSFs and 5 on posterior TDSFs. The general principles were to primarily attempt non-operative management for all TDSFs and to consider operative intervention for anterior TDSFs that remained symptomatic after 3-6 months. Anterior TDSFs showed a prolonged return to sport. The best time to return to sport and the optimal management modalities for TDSFs remain undefined. Management of TDSFs should include a full assessment of training methods, equipment and diet to modify pre-disposing factors. Future prospective studies should aim to establish the optimal treatment modalities for TDSFs. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  2. Mapping the articular contact area of the long head of the biceps tendon on the humeral head.

    Science.gov (United States)

    Morris, Brent J; Byram, Ian R; Lathrop, Ray A; Dunn, Warren R; Kuhn, John E

    2014-01-01

    The purpose of this investigation was to calculate the contact surface area of the long head of the biceps (LHB) in neutral position and abduction. We sought to determine whether the LHB articulates with the humeral head in a consistent pattern comparing articular contact area in neutral position and abduction. Eleven fresh frozen matched cadaveric shoulders were analyzed. The path of the biceps tendon on the articular surface of the humeral head and the total articular surface were digitized using a MicronTracker 2 H3-60 three-dimensional optical tracker. Contact surface area was significantly less in abduction than in neutral position (P = 0.002) with a median ratio of 41% (36%, 47.5%). Ratios of contact area in neutral position to full articular surface area were consistent between left and right shoulders (rho = 1, P = 0.017) as were ratios of abduction area to full articular surface area (rho = 0.97, P = 0.005). The articular contact surface area is significantly greater in neutral position than abduction. The ratios of articular contact surface areas to total humeral articular surface areas have a narrow range and are consistent between left and right shoulders of the same cadaver.

  3. Can arthroscopic rotator cuff repair prevent proximal migration of the humeral head?

    Directory of Open Access Journals (Sweden)

    Pablo Sanz-Ruiz

    2015-12-01

    Full Text Available Introduction: Shoulder arthroscopy has become increasingly used in recent years, especially in rotator cuff repair. The purpose of this study was to determine whether arthroscopic rotator cuff repair could prevent proximal migration of the humeral head. Material and Methods: We performed a retrospective study of 56 patients suffering from shoulder pain. They were divided into two groups, one comprising patients with impingement syndrome who underwent acromioplasty only and another comprising patients with rotator cuff tear who underwent acromioplasty combined with rotator cuff repair. The pre-operative Hirooka angle and the results of the simple shoulder test (SST were compared after 1 year. Results: We found no differences between the groups for the Hirooka angle or SST results. We did find a significant difference (P<0.05 between pre-operative and post-operative SST results. Conclusions: Rotator cuff repair using arthroscopy is a minimally invasive procedure that improves function and prevents proximal migration of the humeral head after 1 year of follow-up. [Arch Clin Exp Surg 2015; 4(4.000: 190-195

  4. Unicameral Bone Cysts in the Humerus: Treatment Outcomes.

    Science.gov (United States)

    Kadhim, Muayad; Sethi, Samir; Thacker, Mihir M

    2016-06-01

    Several treatment modalities have been described for the treatment of unicameral bone cysts (UBC). The aim of this study was to examine the outcome of various treatment modalities of UBC in a specific anatomic location, the humerus. This study is a retrospective case-only study of patients with humeral UBC with minimum follow-up of 1 year. Medical records and radiographs were assessed and UBC healing status was determined based on most recent follow-up radiographs and divided into 3 groups (healed, partially healed, and not healed). Descriptive statistics were utilized to summarize study outcome. Sixty-eight patients (54 boys and 14 girls) with humeral UBC comprised the study population. Sixty-four cases (94.1%) presented with a pathologic fracture. Fifty-one cases were in the proximal metaphysis and 17 were in the diaphysis. Mean age at diagnosis was 9.2±3.7 years, and mean follow-up was 4.0±2.6 years. Twenty-five patients were treated with observation, 38 by injection (27 with steroids and 11 with bone marrow), and 5 by open surgery. Patients who underwent open surgery had relatively larger cyst length, width, and cyst index, and all healed or partially healed at last follow-up. UBC persistence was observed in 29% of diaphyseal and 27.5% of metaphyseal cysts. Of the 19 patients with persistence, 8 were treated with observation, 9 with steroid injection, and 2 with bone marrow injection. Inner wall disruption before injection was performed in 17 patients (24% did not heal), whereas 21 patients did not have inner wall disruption (33% did not heal). Twenty patients received >1 injection. Eleven patients complained of pain at the last visit (8 had a persistent cyst, 2 were partially healed, and 1 had a healed UBC). Complete healing of humeral UBC is challenging to achieve irrespective of treatment modality. UBCs treated with open surgery tended to heal better. Unhealed cysts were more likely to be associated with pain. Level III-a retrospective comparative study.

  5. Is Closed Manipulative Reduction and Percutaneous Kirschner Wiring of Supracondylar Humeral Fracture in Children as Day-Care Surgery a Safe Procedure ?

    Directory of Open Access Journals (Sweden)

    Ashok R Nayak

    2013-07-01

    Full Text Available INTRODUCTION: Supracondylar fracture of the humerus is a common injury in children. It accounts for 60% of fractures around the elbow children. If the fracture is not treated properly it may give rise to many complications like malunion, Volkmann’s ischemic contracture, nerve injury, arterial injury, skin slough, heterotopic bone formation , and stiffness of elbow. The management of displaced supracondylar fracture of the elbow is one of the most difficult of the many fractures seen in children. The purpose of the study was to evaluate the anatomical and functional results of treatment of supracondylar fractures of humerus with closed reduction and percutaneous ‘K’ wire fixation as a day care procedure and record associated complications, thus decreasing the cost of treating these fractures and hospitalization. METHODS: Fifty displaced closed extension type supracondylar fractures (Gartland’s type III of the humerus in children were treated by closed reduction and percutaneous fixation with Kirschner wires. All the patients selected for this study had been treated in a day care unit and were discharged in the same evening and followed up at 3 and 6 weeks and 3 months. Open fractures, fractures with neurovascular complications and children older than 15 yrs were excluded. The final results were evaluated by Flynn’s criteria. RESULTS: The majority (72%, of the patients had fracture displaced posteomedially, Fourty one of the fifty patients had satisfactory results. The majority of the patients were male, and the average age was 8-9 years. CONCLUSION: Percutaneous fixation of supracondylar humerus done as a day care procedure is an acceptable modality of treatment and reduces the duration of hospital stay for the patient.

  6. Humeral head cysts and rotator cuff tears: an MR arthrographic study

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Martin [Southmead Hospital, Department of Radiology, Westbury-on-Trym, Bristol (United Kingdom); Lambert, Robert G.W.; Jhangri, Gian S.; Grace, Michael; Zelaso, Jay; Wong, Ben; Dhillon, Sukhvinder S. [University of Alberta Hospital, Department of Radiology and Diagnostic Imaging, Edmonton (Canada)

    2006-12-15

    Humeral tuberosity cysts are a common finding, with previous reports suggesting they are related to rotator cuff tear or aging. The aim of this study was to investigate the characteristics of cysts in the tuberosities of the humeral head and their relationship with rotator cuff tear and age. Shoulder MR arthrograms were reviewed in 120 consecutive patients - 83 males (mean age 38.0, range 19-59 years) and 37 females (mean age 41.2, range 15-59 years). Patients were referred for investigation of a variety of conditions, and instability was suspected in only a minority of cases. MR was performed before and after direct arthrography with 0.01% solution of gadolinium. Cysts were defined as well-demarcated circular/ovoid foci in two planes that demonstrated high signal on pre-arthrographic T2W sequences. Location, size and numbers of cysts and post-arthrographic enhancement were documented, along with the location of rotator cuff tears, if present. Cysts in the tuberosities of the humerus were identified in 84 patients (70%), and were seen seven times more frequently in the posterior aspect of the greater tuberosity than anteriorly. Most cysts (94%) demonstrated communication with the joint post-arthrogram. Rotator cuff tears were present in 36 patients, and 79% of all tears occurred in supraspinatus tendon. There was no significant difference in the occurrence of cysts between patients older or younger than age 40 or between genders, but rotator cuff tears were seen significantly more often in the older age group (p<0.01). Tuberosity cysts and rotator cuff tears did not appear to be related (p=0.55). However, whilst this lack of association was quite obvious posteriorly (p=0.84), the trend in the anterior aspect of the greater tuberosity is not as clear (p=0.14). Humeral cysts are most often located in the posterior aspect of the greater tuberosity, communicate with the joint space and, in this location, are not related to aging or rotator cuff tear. (orig.)

  7. Humeral head cysts and rotator cuff tears: an MR arthrographic study

    International Nuclear Information System (INIS)

    Williams, Martin; Lambert, Robert G.W.; Jhangri, Gian S.; Grace, Michael; Zelaso, Jay; Wong, Ben; Dhillon, Sukhvinder S.

    2006-01-01

    Humeral tuberosity cysts are a common finding, with previous reports suggesting they are related to rotator cuff tear or aging. The aim of this study was to investigate the characteristics of cysts in the tuberosities of the humeral head and their relationship with rotator cuff tear and age. Shoulder MR arthrograms were reviewed in 120 consecutive patients - 83 males (mean age 38.0, range 19-59 years) and 37 females (mean age 41.2, range 15-59 years). Patients were referred for investigation of a variety of conditions, and instability was suspected in only a minority of cases. MR was performed before and after direct arthrography with 0.01% solution of gadolinium. Cysts were defined as well-demarcated circular/ovoid foci in two planes that demonstrated high signal on pre-arthrographic T2W sequences. Location, size and numbers of cysts and post-arthrographic enhancement were documented, along with the location of rotator cuff tears, if present. Cysts in the tuberosities of the humerus were identified in 84 patients (70%), and were seen seven times more frequently in the posterior aspect of the greater tuberosity than anteriorly. Most cysts (94%) demonstrated communication with the joint post-arthrogram. Rotator cuff tears were present in 36 patients, and 79% of all tears occurred in supraspinatus tendon. There was no significant difference in the occurrence of cysts between patients older or younger than age 40 or between genders, but rotator cuff tears were seen significantly more often in the older age group (p<0.01). Tuberosity cysts and rotator cuff tears did not appear to be related (p=0.55). However, whilst this lack of association was quite obvious posteriorly (p=0.84), the trend in the anterior aspect of the greater tuberosity is not as clear (p=0.14). Humeral cysts are most often located in the posterior aspect of the greater tuberosity, communicate with the joint space and, in this location, are not related to aging or rotator cuff tear. (orig.)

  8. Nonoperative Management and Novel Imaging for Posterior Circumflex Humeral Artery Injury in Volleyball

    NARCIS (Netherlands)

    van de Pol, Daan; Planken, R. Nils; Terpstra, Aart; Pannekoek-Hekman, Marja; Kuijer, P. Paul F. M.; Maas, Mario

    2017-01-01

    We report on a 34-yr-old male elite volleyball player with symptomatic emboli in the spiking hand from a partially thrombosed aneurysm of the posterior circumflex humeral artery (PCHA) in his dominant shoulder. At initial diagnosis and follow-up, a combination of time-resolved and high-resolution

  9. Atypical subtrochanteric and diaphyseal femoral fractures: report of a task force of the American Society for Bone and Mineral Research

    DEFF Research Database (Denmark)

    Shane, Elizabeth; Burr, David; Ebeling, Peter R

    2010-01-01

    Reports linking long-term use of bisphosphonates (BPs) with atypical fractures of the femur led the leadership of the American Society for Bone and Mineral Research (ASBMR) to appoint a task force to address key questions related to this problem. A multidisciplinary expert group reviewed pertinent...... published reports concerning atypical femur fractures, as well as preclinical studies that could provide insight into their pathogenesis. A case definition was developed so that subsequent studies report on the same condition. The task force defined major and minor features of complete and incomplete...

  10. Fracture of the Femur of A Newborn after Cesarean Section for Breech Presentation and Fibroid Uterus :A Case Report and Literature Review

    Directory of Open Access Journals (Sweden)

    Ibrahima Farikou

    2014-01-01

    Full Text Available Introduction: The practice of cesarean section is known to decrease the occurrence of long bone fractures. We present here an unusual diaphyseal fracture of the femur of a newborn after cesarean section, the only case observed in our 14 years of practice. Case Report: The patient was a 3.4-kg female child born at 38 weeks of gestation. The mother was a primipara and aged 39 years. Ultrasound examination at 20th week revealed intrauterine fibroids with a breech presentation. Therefore, elective cesarean section was indicated. There was no apparent bone disorder that could predispose to sustain femur fracture. The fracture was treated successfully with a bilateral spica cast. The cesarean section was indicated in an aged primipara, bearer of uterine fibroids, and breech presentation. She had a good general health status, but her bone density was unknown since this examination is not routinely performed in our clinical settings in Africa. Conclusion: Elderly age, primipara status, presence of uterine fibroids, and breech presentation are usual indications for cesarean section. However, there are not many reports on femur fracture after cesarean section. Our present case suggests that despite the latest advances in delivery techniques, cesarean section for breech presentation predisposes the neonate to femoral fractures. Keywords: Femur fracture; Cesarean section; Fibroid; Breech presentation; Africa.

  11. Complex proximal humerus fractures: Hertel's criteria reliability to predict head necrosis.

    Science.gov (United States)

    Campochiaro, G; Rebuzzi, M; Baudi, P; Catani, F

    2015-09-01

    The risk of post-traumatic humeral head avascular necrosis (AVN), regardless of the treatment, has a high reported incidence. In 2004, Hertel et al. stated that the most relevant predictors of ischemia after intracapsular fracture treated with osteosynthesis are the calcar length, medial hinge integrity and some specific fracture types. Based on Hertel's model, the purpose of this study is to evaluate both its reliability and weaknesses in our series of 267 fractures, assessing how the anatomical configuration of fracture, the quality of reduction and its maintenance were predictive of osteonecrosis development, and so to suggest a treatment choice algorithm. A retrospective study, level of evidence IV, was conducted to duly assess the radiographic features of 267 fractures treated from 2004 to 2010 following Hertel's criteria treated with open reduction and internal fixation by angular stability plates and screws. The average age was 65.2 years. The average follow-up was 28.3 ± 17.0 months. The percentage of AVN, the quality and maintenance of reduction obtained during surgery were evaluated. The AVN incidence was 3.7 %. No significant correlation with gender, age and fracture type was found. At the last follow-up X-ray, only 30 % presented all Hertel's good predictors in the AVN group, 4.7 % in the non-AVN group (p AVN group, it was poor in 50 %; while in the non-AVN group, it was poor in 3.4 % (p AVN were symptomatic, and three needed a second surgery. Hertel's criteria are important in the surgical planning, but they are not sufficient: an accurate evaluation of the calcar area fracture in three planes is required. All fractures involving calcar area should be studied with CT.

  12. Spike the PCHA! Overuse injury of the Posterior Circumflex Humeral Artery in elite volleyball

    NARCIS (Netherlands)

    van de Pol, D.

    2016-01-01

    In 1993, professor Reekers of the Academic Medical Center (AMC) Radiology department was the first to describe a traumatic aneurysm of the posterior circumflex humeral artery (PCHA) in a volleyball player, suggesting a causal relationship. Fifteen years later, between 2008 and 2010, several elite

  13. Evaluation of the effect of platelet rich plasma (PRP) on enhancement of bone healing in diaphyseal bone defects by radiography and computed tomography

    International Nuclear Information System (INIS)

    Özak, Ahmet; Yardimci, Cenk; Nİsbet, Özlem H.; Bayrak, İlkay Koray; Nİsbet, Cevat

    2010-01-01

    The effect of platelet-rich plasma (PRP) with autogenous cancellous bone graft on enhancement of bone healing in diaphyseal bone defects was evaluated. A 4-mm defect was created in the middiaphysis of the tibias of 20 rabbits. Rabbits were divided into two groups of ten animals each: only autogenous cancellous graft, PRP and autogenous cancellous graft. In animals of group 1, only autogenous cancellous grafts, and to those in group 2, PRP and autogenous cancellous grafts, were applied to the defect. Radiographical and computed tomography (CT) views were taken and evaluated on postoperative days 0, 15, 30, 60, and 90. According to the bone formation, union, and remodeling scores, group 1 had better scores than group 2 on days 30, 60, and 90. The density was significantly increased on day 60 than on days 0, 15, and 30 in group 1. In conclusion, it was evaluated that PRP could not enhance the bone regeneration in diaphyseal defects when used with autogenous cancellous bone graft

  14. Mapping the Articular Contact Area of the Long Head of the Biceps Tendon on the Humeral Head

    Directory of Open Access Journals (Sweden)

    Brent J. Morris

    2014-01-01

    Full Text Available The purpose of this investigation was to calculate the contact surface area of the long head of the biceps (LHB in neutral position and abduction. We sought to determine whether the LHB articulates with the humeral head in a consistent pattern comparing articular contact area in neutral position and abduction. Eleven fresh frozen matched cadaveric shoulders were analyzed. The path of the biceps tendon on the articular surface of the humeral head and the total articular surface were digitized using a MicronTracker 2 H3-60 three-dimensional optical tracker. Contact surface area was significantly less in abduction than in neutral position (P=0.002 with a median ratio of 41% (36%, 47.5%. Ratios of contact area in neutral position to full articular surface area were consistent between left and right shoulders (rho=1, P=0.017 as were ratios of abduction area to full articular surface area (rho= 0.97, P=0.005. The articular contact surface area is significantly greater in neutral position than abduction. The ratios of articular contact surface areas to total humeral articular surface areas have a narrow range and are consistent between left and right shoulders of the same cadaver.

  15. A lateral approach to the repair of propagating fractures of the medial condyle of the third metacarpal and metatarsal bone in 18 racehorses.

    Science.gov (United States)

    Wright, Ian M; Smith, Matthew R W

    2009-08-01

    To report the technique, observations on fracture configurations and results of treatment by fixation lag screw following the fracture plane determined by an approach to the third metacarpal/metatarsal bone (MC3/MT3) that begins laterally over the metacarpo(metatarso)phalangeal joint and extends dorsally over the diaphysis of the bone. Case series. Thoroughbred horses (n=18) with propagating fractures of the medial condyle of MC3/MT3. Retrospective analysis of case records of horses with fractures of the medial condyle of MC3/MT3 that propagated sagittaly or in a spiral configuration into the diaphysis, repaired surgically under general anesthesia by screw fixation in lag fashion through a lateral approach with periosteal reflection. Fractures were readily identified at surgery, enabling screw fixation in lag fashion following the fracture plane. Fracture configurations varied and could be classified as sagittal and spiral fractures with fractures within each group generally following a similar course. All horses recovered relatively uneventfully from general anesthesia and surgery, and all fractures healed well. Thirteen horses returned to training; 5 subsequently raced. Repair of propagating sagittal and spiral fractures of the medial condyle of MC3/MT3 with diaphyseal involvement, through a lateral approach with periosteal reflection permits stable fixation with minimal complications. In this series there were no catastrophic failures. Fractures of the medial condyle of MC3/MT3 that propagate either sagittaly or in a spiral configuration into the diaphysis can be successfully repaired with screw fixation in lag fashion using a lateral approach with periosteal reflection.

  16. Methods and theory in bone modeling drift: comparing spatial analyses of primary bone distributions in the human humerus.

    Science.gov (United States)

    Maggiano, Corey M; Maggiano, Isabel S; Tiesler, Vera G; Chi-Keb, Julio R; Stout, Sam D

    2016-01-01

    This study compares two novel methods quantifying bone shaft tissue distributions, and relates observations on human humeral growth patterns for applications in anthropological and anatomical research. Microstructural variation in compact bone occurs due to developmental and mechanically adaptive circumstances that are 'recorded' by forming bone and are important for interpretations of growth, health, physical activity, adaptation, and identity in the past and present. Those interpretations hinge on a detailed understanding of the modeling process by which bones achieve their diametric shape, diaphyseal curvature, and general position relative to other elements. Bone modeling is a complex aspect of growth, potentially causing the shaft to drift transversely through formation and resorption on opposing cortices. Unfortunately, the specifics of modeling drift are largely unknown for most skeletal elements. Moreover, bone modeling has seen little quantitative methodological development compared with secondary bone processes, such as intracortical remodeling. The techniques proposed here, starburst point-count and 45° cross-polarization hand-drawn histomorphometry, permit the statistical and populational analysis of human primary tissue distributions and provide similar results despite being suitable for different applications. This analysis of a pooled archaeological and modern skeletal sample confirms the importance of extreme asymmetry in bone modeling as a major determinant of microstructural variation in diaphyses. Specifically, humeral drift is posteromedial in the human humerus, accompanied by a significant rotational trend. In general, results encourage the usage of endocortical primary bone distributions as an indicator and summary of bone modeling drift, enabling quantitative analysis by direction and proportion in other elements and populations. © 2015 Anatomical Society.

  17. HEALING OF ARTICULAR AND PERIARTICULAR METACARPAL AND PHALANGEAL FRACTURES

    Directory of Open Access Journals (Sweden)

    Aleksandar Kruščić

    2003-12-01

    Full Text Available Background. Primary treatment of 779 closed epiphysial, diaphyseal, comminutive, oblique and periarticular fractures of metacarpals and phalanges was carried out with painless reposition and fixation with a plaster splint. In 435 cases, fracture slides occurred after one week. For correction, the ligamentotaxis metod with aluminium (Alu- splint and Softcast plaster was used. This method allows the retaining of a good position of fractured fragments after reposition by neutralization of the pathologic action of kinetic vectors on these fragments. Our goal in using this method is to stabilize the fractured fragments individually with consideration of soft tissues.Methods. In local (in the fracture or Oberst analgesia, a correct size Alu-splint is placed over the wad-protected skin on the volar or dorsal side of the hand. The Alu-splint is fixed with Urgopore proximally and distally from the fracture. Then, correction using the reduction technique over the Alu-splinting is done. Such correction is followed by X-ray control and if the fragments are in good position, the construction is fixed with plaster. One week later, X-ray control verifies the position of broken parts.Results. In the year 2000, 740 outpatients with a total of 779 (100% metacarpal and phalangeal fractures were treated. There were 569 (73% men and 210 (27% women. The incidence in men was highest in the 10–19 years age group with 143 fractures. In the 50–59 years group, the incidence was equal in men and women (69 fractures. The highest prevalence of fracture slides was in the group of proximal phalanx fractures (190 fractures or 44%. X-ray control after one week showed 435 (56% fracture slides in immobilization with plaster. This high percentage is due to a severe damage to skeletal connective tissue. 321 (41% fractures were re-repositioned with ligamentotaxis, 172 (22% fracture slides were treated using other methods (e.g. surgery. 385 (49% fractures treated with

  18. A PROSPECTIVE STUDY OF DISTAL TIBIAL FRACTURES BY MIPO (LCP

    Directory of Open Access Journals (Sweden)

    Chandra Sekharam Naidu

    2015-05-01

    contact . 9 MIPO promoted by AO group emphasis on indirect reduction, axial alignment and s table fixation without disturbing the fracture environment and thus preserving most of the vascularization and fracture haematoma, containing all necessary growth factors for bony healing. Technique of closed reduction and MIPPO with LCP has emerged as an alternative treatment option for distal dia - metaphyseal tibia fracture. When applied subcutaneously, LCP does not endanger periosteal blood supply, respect fracture heamtoma and also provides biomechanically stable construct. Several clinical studies have established MIPO with LCP as a biologically friendly and technically sound method of fixation for distal meta - diaphyseal tibial fracture.

  19. Contact mechanics of reverse engineered distal humeral hemiarthroplasty implants.

    Science.gov (United States)

    Willing, Ryan; King, Graham J W; Johnson, James A

    2015-11-26

    Erosion of articular cartilage is a concern following distal humeral hemiarthroplasty, because native cartilage surfaces are placed in contact with stiff metallic implant components, which causes decreases in contact area and increases in contact stresses. Recently, reverse engineered implants have been proposed which are intended to promote more natural contact mechanics by reproducing the native bone or cartilage shape. In this study, finite element modeling is used in order to calculate changes in cartilage contact areas and stresses following distal humeral hemiarthroplasty with commercially available and reverse engineered implant designs. At the ulna, decreases in contact area were -34±3% (p=0.002), -27±1% (pengineered and cartilage reverse engineered designs, respectively. Peak contact stresses increased by 461±57% (p=0.008), 387±127% (p=0.229) and 165±16% (p=0.003). At the radius, decreases in contact area were -21±3% (p=0.013), -13±2% (p0.999), 241±32% (p=0.010) and 61±10% (p=0.021). Between the three different implant designs, the cartilage reverse engineered design yielded the largest contact areas and lowest contact stresses, but was still unable to reproduce the contact mechanics of the native joint. These findings align with a growing body of evidence indicating that although reverse engineered hemiarthroplasty implants can provide small improvements in contact mechanics when compared with commercially available designs, further optimization of shape and material properties is required in order reproduce native joint contact mechanics. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. The effect of canal fill on paediatric femur fractures treated with titanium elastic nails.

    Science.gov (United States)

    Nielsen, E; Bonsu, N; Andras, L M; Goldstein, R Y

    2018-02-01

    Traditional teaching for fixation of paediatric femur fractures recommends 80% nail diameter/medullary canal diameter ratio (ND/MCD) for successful maintenance of reduction. Prior studies have investigated this with stainless steel Enders nails. Our aim was to assess the impact of ND/MCD on maintenance of reduction and malunion rates in paediatric femur fractures treated with flexible intramedullary nails (FINs). Retrospective data was collected on all paediatric patients treated with FINs for diaphyseal femur fractures at a single tertiary care institution over a ten-year period. Patients with co-morbidities affecting bone quality were excluded. Patients were subdivided into groups based on ND/MCD. A total of 66 patients met inclusion criteria. Mean ND/MCD was 76.3% (32.9% to 98.8%, SD 14.3). In all, 50% (n = 33/66) of patients had > 80% ND/MCD, and only 13.6% (n = 9/66) of patients had less than 60% ND/MCD. When controlling for fracture stability, ND/MCD had no correlation with mean shortening (p = 0.07) There was no correlation between ND/MCD and angulation in the sagittal (p = 0.96) or coronal plane (p = 0.20). Three patients fit malunion criteria. ND/MCD for these patients were 40%, 67% and 79%. There was no correlation between ND/MCD and shortening or malangulation. The majority of patients in this series with less than 80% fill with FIN healed within acceptable parameters. III.

  1. Bony defects in chronic anterior posttraumatic dislocation of the shoulder: Is there a correlation between humeral and glenoidal lesions?

    Science.gov (United States)

    Ciais, Grégoire; Klouche, Shahnaz; Fournier, Alexandre; Rousseau, Benoit; Bauer, Thomas; Hardy, Philippe

    2016-08-01

    The prevalence of combined humeral and glenoid defects varies between 79 and 84 % in case of chronic posttraumatic anterior shoulder instability. The main goal of this study was to evaluate the relationship between humeral and glenoid defects based on quantitative radiological criteria. A retrospective study was performed between 2000 and 2011 including patients who underwent primary surgical shoulder stabilization for chronic posttraumatic anterior shoulder instability, with bone defects in both the glenoid and humerus and a healthy contralateral shoulder. The following measurements were taken: D/R ratio (Hill-Sachs lesion depth/humeral head radius) on an AP X-ray in internal rotation and the D1/D2 ratio [diameter of the involved glenoid articular surfaces (D1)/the healthy one (D2)] on a comparative Bernageau glenoid profile view. Measurements were taken by two observers. Correlations were determined by the Spearman correlation coefficients (r), Bland and Altman diagrams, and intra-class correlation coefficients (ICC). A sample size calculation was done. Thirty patients were included, 25 men/5 women, mean age 29.8 ± 11.2 years. The mean D/R was 23 ± 12 % for observer 1 and 23 ± 10 % for observer 2. The mean D1/D2 was 95 ± 4 % for observer 1 and 94 ± 6 % for observer 2. No significant correlation was found between humeral and glenoid bone defects by observer 1 (r = 0.23, p = 0.22) or observer 2 (r = 0.05, p = 0.78). Agreement of the observers for the D/R ratio was excellent (ICC = 0.89 ± 0.04, p < 0.00001) and good for the D1/D2 ratio (ICC = 0.54 ± 0.14, p = 0.006). Humeral and glenoid bone defects were not correlated. Inter-observer reliability was excellent for the D/R ratio and good for the D1/D2 ratio. Nonconsecutive Patients, Diagnostic Study, Level III.

  2. Prevalence of humeral head osteochondrosis in the Greater Swiss Mountain dog and the Border Collie in Switzerland.

    Science.gov (United States)

    Ohlerth, S; Senn, S; Geissbühler, U; Kircher, P; Flückiger, M

    2016-11-01

    Osteochondrosis (OC) is common in large-breed dogs. According to the breeding guidelines of the Swiss kennel clubs, the shoulder joints are included in the radiographic screening for joint diseases in the Greater Swiss Mountain dog (GSMD) and the Border Collie (BC) since 1993 and 2003, respectively. The aim of this study was to estimate the overall prevalence of humeral head OC in these 2 breeds in Switzerland based on the data of the Swiss National Dysplasia Committees. All radiographs were re-evaluated to assess single radiographic changes. From 1993 and 2003, accordingly, until 2013, the overall prevalence was 14% for the GSMD and 8% for the BC, respectively. Affected joints showed a focally reduced opacity or a flattened/indented contour of the caudal section of the humeral head. Articular flaps were only seen occasionally. Degenerative joint disease was significantly more common in OC affected joints (GSMD: 32%; BC: 20%) than in joints without OC. The present study is the first report on the prevalence of humeral head OC in a large cohort of GSMD and the BC over a long study period. In comparison to other breeds, the herein reported prevalences are in the mid to upper range. Results of the present study should alert veterinarians to the disease in these breeds and may serve as a starting point for further epidemiological and genetic studies.

  3. Failed Surgical Management of Acute Proximal Fifth Metatarsal (Jones) Fractures: A Retrospective Case Series and Literature Review.

    Science.gov (United States)

    Granata, Jaymes D; Berlet, Gregory C; Philbin, Terrence M; Jones, Grant; Kaeding, Christopher C; Peterson, Kyle S

    2015-12-01

    Nonunion, delayed union, and refracture after operative treatment of acute proximal fifth metatarsal fractures in athletes is uncommon. This study was a failure analysis of operatively managed acute proximal fifth metatarsal fractures in healthy athletes. We identified 149 patients who underwent operative treatment for fifth metatarsal fractures. Inclusion criteria isolated skeletally mature, athletic patients under the age of 40 with a minimum of 1-year follow-up. Patients were excluded with tuberosity fractures, fractures distal to the proximal metaphyseal-diaphyseal region of the fifth metatarsal, multiple fractures or operative procedures, fractures initially treated conservatively, and medical comorbidities/risk factors for nonunion. Fifty-five patients met the inclusion/exclusion criteria. Four (7.3%) patients required a secondary operative procedure due to refracture. The average time to refracture was 8 months. All refractures were associated with bent screws and occurred in male patients who participated in professional basketball, professional volleyball, and college football. The average time for release to progressive weight-bearing was 6 weeks. Three patients were revised to a bigger size screw and went on to union. One patient was revised to the same-sized screw and required a second revision surgery for nonunion. All failures were refractures in competitive athletes who were initially treated with small diameter solid or cannulated stainless steel screws. The failures were not associated with early postoperative weight-bearing protocol. Maximizing initial fixation stiffness may decrease the late failure rate in competitive athletes. More clinical studies are needed to better understand risk factors for failure after screw fixation in the competitive, athletic population. Prognostic, Level IV: Case series. © 2015 The Author(s).

  4. Revascularization of diaphyseal bone segments by vascular bundle implantation.

    Science.gov (United States)

    Nagi, O N

    2005-11-01

    Vascularized bone transfer is an effective, established treatment for avascular necrosis and atrophic or infected nonunions. However, limited donor sites and technical difficulty limit its application. Vascular bundle transplantation may provide an alternative. However, even if vascular ingrowth is presumed to occur in such situations, its extent in aiding revascularization for ultimate graft incorporation is not well understood. A rabbit tibia model was used to study and compare vascularized, segmental, diaphyseal, nonvascularized conventional, and vascular bundle-implanted grafts with a combination of angiographic, radiographic, histopathologic, and bone scanning techniques. Complete graft incorporation in conventional grafts was observed at 6 months, whereas it was 8 to 12 weeks with either of the vascularized grafts. The pattern of radionuclide uptake and the duration of graft incorporation between vascular segmental bone grafts (with intact endosteal blood supply) and vascular bundle-implanted segmental grafts were similar. A vascular bundle implanted in the recipient bone was found to anastomose extensively with the intraosseous circulation at 6 weeks. Effective revascularization of bone could be seen when a simple vascular bundle was introduced into a segment of bone deprived of its normal blood supply. This simple technique offers promise for improvement of bone graft survival in clinical circumstances.

  5. GROSS ANATOMY AND SURGICAL APPROACH TO THE HUMERAL SHAFT IN GIANT ANTEATER (MYRMECOPHAGA TRIDACTYLA).

    Science.gov (United States)

    Sesoko, Natália Ferreira; Rahal, Sheila Canevese; Bortolini, Zara; Merlini, Natalie Bertelis; Teixeira, Carlos Roberto

    2016-09-01

    Anteater forelimbs are distinguished morphologically from domestic animals, especially due to their unique movement and their natural habits. A knowledge of the pectoral limb anatomy and the proper surgical approach are fundamental to success in osteosynthesis and other surgeries. This study aimed to describe the muscles and neurovascular structures of the pectoral limb and the surgical approach to the humeral shaft of the giant anteater ( Myrmecophaga tridactyla ). Dissections of the forelimbs of seven cadavers were performed to identify the major muscles and neurovascular structures. Three of these animals' contralateral forearms were used to simulate the surgical approach to the humeral shaft. Some specific characteristics of the muscle morphology were biceps muscle had two heads, triceps muscle had three heads, and there was an olecranon-epicondylar muscle. To expose the shaft of the humerus, it was necessary to incise the superficial pectoral muscle and separate the heads of the biceps muscle. Due to the anatomical characteristics of the humerus, the craniomedial approach was the most appropriate because it accommodated the anatomical peculiarities of the giant anteater.

  6. Identification of Recent Bats belonging to the Rhinolophidae by the Humeral Characters

    OpenAIRE

    Yoon, Myung Hee; Uchida, Teruaki; 内田, 照章

    1983-01-01

    Humeral characters of eleven recent species and one subspecies belonging to three genera of the Rhinolophidae including two subfamilies were described. A key provides for their identification as well as the identification of the fossil bats found on the Akiyoshi-dai Plateau. Further, we discussed differences in the adaptability for flight of the bats not only within each taxon of the family but also between the phylogenetically less advanced Rhinolophidae and the more advanced Vespertilionida...

  7. Is Contralateral Templating Reliable for Establishing Rotational Alignment During Intramedullary Stabilization of Femoral Shaft Fractures? A Study of Individual Bilateral Differences in Femoral Version.

    Science.gov (United States)

    Croom, William P; Lorenzana, Daniel J; Auran, Richard L; Cavallero, Matthew J; Heckmann, Nathanael; Lee, Jackson; White, Eric A

    2018-02-01

    To determine native individual bilateral differences (IBDs) in femoral version in a diverse population. Computed tomography scans with complete imaging of uninjured bilateral femora were used to determine femoral version and IBDs in version. Age, sex, and ethnicity of each subject were also collected. Femoral version and IBDs in version were correlated with demographic variables using univariate and multivariate regression models. One hundred sixty-four subjects were included in the study. The average femoral version was 9.4 degrees (±9.4 degrees). The mean IBD in femoral version was 5.4 degrees (±4.4 degrees, P alignment during intramedullary stabilization of diaphyseal femur fractures. This is also an important consideration when considering malrotation of femur fractures because most studies define malrotation as a greater than 10-15-degree difference compared with the contralateral side. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  8. TREATMENT OF TRANSCONDYLAR EXTENSOR FRACTURES OF THE HUMERUS IN CHILDREN: ON THE ISSUE OF HISTORY OF THE METHOD “COLLAR AND CUFF”

    Directory of Open Access Journals (Sweden)

    A. S. Zolotov

    2013-01-01

    Full Text Available The article is devoted to the history of one of the methods of conservative treatment humeral transcondylar extensor fractures in children - a method «collar and cuff». The second and very common name of this method is connected with the name of the american orthopaedist Walter Blount. «The method of Blount» is mentioned in many domestic and foreign sources. Nevertheless the analysis of publications on the history of the discussed method of treatment indicates the priority in this matter other famous doctor - British podiatrist Robert Jones.

  9. Three-part head-splitting proximal humerus fracture through a unicameral bone cyst.

    Science.gov (United States)

    Younghein, John A; Eskander, Mark S; DeAngelis, Nicola A; Wixted, John J

    2012-06-01

    Unicameral bone cysts are rare in adults and are most often found incidentally on radiographs. However, they can persist from the adolescent period and may be present in locations that predispose to or exacerbate fractures.This article describes a case of a healthy 40-year-old woman who sustained a proximal humerus trauma that involved a large unicameral bone cyst, resulting in a 3-part head-splitting fracture. The epiphyseal location of the cyst contributed to the severity and extent of the fracture that resulted from a simple fall. Given the age of the patient, open reduction and internal fixation with a locking plate and lag screws was performed. The patient chose open reduction and internal fixation to preserve a hemiarthroplasty procedure in case of future revision. Successful humeral head reconstruction was achieved, and the patient fully recovered. One year postoperatively, the patient underwent arthroscopic debridement to alleviate subjective stiffness and decreased range of motion.Multipart head-splitting fractures require complex repair strategies. The gold standard for the treatment of these injuries is hemiarthroplasty. However, the decision process is difficult in a young patient given the average survival of autoplastic prostheses and the added difficulty of later revision. The current case demonstrates the complexity of decision making resulting from a rare injury in a young, healthy patient and shows that open reduction and internal fixation can provide acceptable reconstruction in such situations. Copyright 2012, SLACK Incorporated.

  10. Can a semi-automated surface matching and principal axis-based algorithm accurately quantify femoral shaft fracture alignment in six degrees of freedom?

    Science.gov (United States)

    Crookshank, Meghan C; Beek, Maarten; Singh, Devin; Schemitsch, Emil H; Whyne, Cari M

    2013-07-01

    Accurate alignment of femoral shaft fractures treated with intramedullary nailing remains a challenge for orthopaedic surgeons. The aim of this study is to develop and validate a cone-beam CT-based, semi-automated algorithm to quantify the malalignment in six degrees of freedom (6DOF) using a surface matching and principal axes-based approach. Complex comminuted diaphyseal fractures were created in nine cadaveric femora and cone-beam CT images were acquired (27 cases total). Scans were cropped and segmented using intensity-based thresholding, producing superior, inferior and comminution volumes. Cylinders were fit to estimate the long axes of the superior and inferior fragments. The angle and distance between the two cylindrical axes were calculated to determine flexion/extension and varus/valgus angulation and medial/lateral and anterior/posterior translations, respectively. Both surfaces were unwrapped about the cylindrical axes. Three methods of matching the unwrapped surface for determination of periaxial rotation were compared based on minimizing the distance between features. The calculated corrections were compared to the input malalignment conditions. All 6DOF were calculated to within current clinical tolerances for all but two cases. This algorithm yielded accurate quantification of malalignment of femoral shaft fractures for fracture gaps up to 60 mm, based on a single CBCT image of the fractured limb. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  11. The effect of inferomedial screw on postoperative shoulder function and mechanical alignment in proximal humerus fractures.

    Science.gov (United States)

    Erdoğan, Murat; Desteli, Engin Eren; İmren, Yunus; Üztürk, Ali; Kılıç, Mesut; Sezgin, Hicabi

    2014-10-01

    The aim of the study was to evaluate the clinical and radiologic results of locking plate fixation with or without inferomedial screw (IMS) in surgically treated proximal humerus fractures. Thirty-six patients with displaced proximal humerus fractures from two centers were operated using locking plate. All of the fractures were classified according to the Neer classification. In 18 of the cases, an additional IMS running through the medial curvature of the surgical neck was used. There was no significant difference among both groups in terms of height, gender, weight, and mechanism of injury. The fractures were evaluated according to the radiographic and functional findings during follow-up period of 14 months in average (range 8-32 months). At the end of first year, shoulder radiographs were received and shoulder examinations were performed using ASES scores. Humeral head-shaft angles were measured by true AP projections. Head-shaft angle measurements were categorized as varus if 145. Mean time for fracture healing was 18 weeks. Complete union was achieved in 35 patients by the end of 6 months. In one of the 18 displaced proximal humerus fractures of IMS (+) group, the head-shaft angle was measured to be <125, whereas six patients had varus deviation in IMS (-) group at follow-up (p < 0.05). Mean ASES scores of IMS (+) group and IMS (-) group were 58.21 ± 5.82 and 38.61 ± 3.44, respectively (p < 0.001). Use of inferomedial screw running through the medial curvature of surgical neck prevents varus deformity and improves functional outcome after surgical treatment for proximal humerus fractures.

  12. DYNAMICS OF THE FUNCTIONAL STATUS OF PATIENTS IN THE TREATMENT OF CLAVICLE FRACTURES BY TRANSOSSEOUS OSTEOSYNTHESIS

    Directory of Open Access Journals (Sweden)

    V. A. Shchurov

    2013-01-01

    Full Text Available Purpose - assessment of the dynamics of the state, blood supply regenerate bone, muscle contractility of the arm and forearm in patients with clavicle fractures during the treatment with external fixation device. Material and methods. Authors studied 38 patients during the treatment by Ilizarov method. The muscle dynamometry, Doppler ultrasound, psychophysiological study using SF-36 test were performed. Results. The strength of the humeral and forearm muscles on the side of damage was reduced and increased by 50-80% of the conditional baseline during transosseous fixation. The high rate of blood flow in the area of injury was characteristic during the first week in the fixation period. In the process of the treatment and recovery of muscle contractility its value normalized. The treatment of clavicle fractures by Ilizarov method allows in the early period of fixation to restore the ability of patients to self-service, to reduce the influence of pain limiting factor, improves mood and health of patients.

  13. Osteossíntese de fratura diafisária do úmero com placa em ponte: apresentação e descrição da técnica Osteosynthesis of the humeral shaft fractures, with bridge plate

    Directory of Open Access Journals (Sweden)

    Bruno Livani

    2004-06-01

    Full Text Available Os autores descrevem o método cirúrgico inédito para o tratamento das fraturas da diáfise do úmero, com placa colocada por técnica minimamente invasiva. Após estudos anatômicos, foram identificadas três acessos cirúrgicos pelos quais se pode introduzir uma placa na face anterior do úmero, sem risco de lesão vásculo nervosa. O acesso proximal se faz entre os múculos deltóide, lateralmente, e bíceps braquial, medialmente. Nas fraturas do terço médio o acesso distal é feito entre os músculos bíceps braquial e braquial com a placa introduzida de proximal para distal. Nas fraturas distais do úmero o acesso proximal é o mesmo, mas o acesso distal é o descrito por Kocher, com a placa introduzida de distal para proximal e fixada na face anterior da coluna lateral do úmero. O método aqui apresentado vem sendo utilizado desde junho de 2001, principalmente nos pacientes politraumatizados e polifraturados, por ser rápida, segura e por permitir que o paciente possa ser operado em decúbito dorsal horizontal. Além disso, não há necessidade de intensificador de imagem, ou mesmo aparelho de radiografia. Até o momento não foram observadas complicações vásculo nervosas nos 22 pacientes tratados.The authors describe for the first time ever a minimally invasive plate osteosythesis for the treatment of the humeral shatf fractures. After anatomic human cadaver's studies, it was identified three surgical approaches for plate percutaneous insertion on the anterior surface of the humerus without vascular and nervous injury. The proximal approach is between the biceps and deltoid muscles. The distal approach for medial third fractures is between the biceps brachialis and brachialis muscles. The plate is inserted from the proximal to distal direction. For distal fractures, the proximal approach is the same described by Krocher, with the plate inserted from distal to proximal and fixed on the anterior surface of the lateral column of the

  14. Denervation of the lateral humeral epicondyle for treatment of chronic lateral epicondylitis.

    Science.gov (United States)

    Rose, Nicholas E; Forman, Scott K; Dellon, A Lee

    2013-02-01

    Chronic lateral epicondylitis remains a treatment challenge. Traditional surgical treatments for lateral epicondylitis involve variations of the classic Nirschl lateral release. Anatomic studies reveal that the posterior branch or branches of the posterior cutaneous nerve of the forearm consistently innervate the lateral humeral epicondyle. We undertook the present study to determine the effectiveness of denervation of the lateral humeral epicondyle in treating chronic lateral epicondylitis. An institutional review board-approved prospective study included 30 elbows in 26 patients. Inclusion criteria included failure to respond to nonoperative treatment for more than 6 months and improvement in grip strength and in visual analog pain scale after diagnostic nerve block of the posterior branches of the posterior cutaneous nerve of the forearm proximal to the lateral humeral epicondyle. We excluded patients who had undergone previous surgery for lateral epicondylitis. Outcome measures included visual analog pain scale and grip strength testing. Denervation surgery involved identification and transection of the posterior cutaneous nerve of the forearm branches with implantation into the triceps. The presence of radial tunnel syndrome was noted but did not affect inclusion criteria; if it was present, we did not correct it surgically. We used no postoperative splinting and permitted immediate return to activities of daily living. At a mean of 28 months of follow-up, the average visual analog scale score decreased from 7.9 to 1.9. Average grip strength with the elbow extended improved from 13 to 24 kg. A total of 80% of patients had good or excellent results, as defined by an improvement of 5 or more points on the visual analog scale for pain. Denervation of the lateral epicondyle was effective in relieving pain in 80% of patients with chronic lateral epicondylitis who had a positive response to a local anesthetic block of the posterior branches of the posterior

  15. Post-market Surveillance Study With the HYPERION Hip Endoprosthesis System in Defect Reconstruction

    Science.gov (United States)

    2017-12-19

    Osteoarthritis; Avascular Necrosis; Rheumatoid Arthritis; Functional Deformities; Pseudoarthrosis; Revision of Endoprosthesis-treated Hips; Fracture, Proximal Humeral; Provision of Non-endoprosthetic Previous Operations of the Hip Joint (e.g., Transposition Osteotomies); Femur Fracture; Pseudarthrosis; Trochanteric Fractures; Bridging of Large Bone Defects; Revisions

  16. A Randomized Cadaver Study Comparing First-Attempt Success Between Tibial and Humeral Intraosseous Insertions Using NIO Device by Paramedics: A Preliminary Investigation.

    Science.gov (United States)

    Szarpak, Lukasz; Truszewski, Zenon; Smereka, Jacek; Krajewski, Paweł; Fudalej, Marcin; Adamczyk, Piotr; Czyzewski, Lukasz

    2016-05-01

    Medical personnel may encounter difficulties in obtaining intravenous (IV) access during cardiac arrest. The 2015 American Heart Association guidelines and the 2015 European Resuscitation Council guidelines for cardiopulmonary resuscitation (CPR) suggest that rescuers establish intraosseous (IO) access if an IV line is not easily obtainable.The aim of the study was to compare the success rates of the IO proximal tibia and proximal humerus head access performed by paramedics using the New Intraosseous access device (NIO; Persys Medical, Houston, TX, USA) in an adult cadaver model during simulated CPR.In an interventional, randomized, crossover, single-center cadaver study, a semi-automatic spring-load driven NIO access device was investigated. In total, 84 paramedics with less than 5-year experience in Emergency Medical Service participated in the study. The trial was performed on 42 adult cadavers. In each cadaver, 2 IO accesses to the humerus head, and 2 IO accesses to the proximal tibia were obtained.The success rate of the first IO attempt was 89.3% (75/84) for tibial access, and 73.8% (62/84) for humeral access (P = 0.017). The procedure times were significantly faster for tibial access [16.8 (interquartile range, IQR, 15.1-19.9] s] than humeral access [26.7 (IQR, 22.1-30.9) s] (P < 0.001).Tibial IO access is easier and faster to put in place than humeral IO access. Humeral IO access can be an alternative method to tibial IO access. clinicaltrials.gov Identifier: NCT02700867.

  17. The efficacy of single-stage open intramedullary nailing of neglected femur fractures.

    Science.gov (United States)

    Boopalan, P R J V C; Sait, Azad; Jepegnanam, Thilak Samuel; Matthai, Thomas; Varghese, Viju Daniel

    2014-02-01

    Neglected femur fractures are not rare in the developing world. Treatment options include single-stage open reduction and intramedullary nailing, or open release, skeletal traction, and then second-stage open intramedullary nailing, with bone grafting. Single-stage procedures have the potential advantage of avoiding neurovascular complications secondary to acute lengthening, but they require a second operation, with potentially increased resource use and infection risk. We sought to determine the (1) likelihood of union, (2) complications and reoperations, and (3) functional results with single-stage open intramedullary nailing without bone grafting in patients with neglected femur fractures. Between January 2003 and December 2007, 17 consecutive patients presented to our practice with neglected femoral shaft fractures. All were treated with single-stage nailing without bone grafting. There were 15 men and two women with a median age of 27 years. The average time from fracture to treatment was 13 weeks (range, 4-44 weeks). Eleven patients underwent open nailing with interlocked nails and six were treated with cloverleaf Kuntscher nails. Patients were followed for a minimum of 6 months (mean, 33 months; range, 6-72 months). The mean preoperative ROM of the knee was 28° (range, 10°-150°) and femoral length discrepancy was 3.1 cm (range, 1-5 cm). All fractures united and the mean time to union was 16 weeks (range, 7-32 weeks). There were no neurologic complications secondary to acute lengthening. The mean postoperative ROM of the knee was 130° (range, 60°-150°). All patients were able to return to preinjury work. Sixteen patients regained their original femoral length. One-stage open intramedullary nailing of neglected femoral diaphyseal fractures without bone grafting was safe and effective, and obviated the need for a two-stage approach. Although the findings need to be replicated in larger numbers of patients, we believe this technique may be useful in

  18. Low serum magnesium levels are associated with increased risk of fractures: a long-term prospective cohort study.

    Science.gov (United States)

    Kunutsor, Setor Kwadzo; Whitehouse, Michael Richard; Blom, Ashley William; Laukkanen, Jari Antero

    2017-07-01

    Magnesium, which is an essential trace element that plays a key role in several cellular processes, is a major component of bone; however, its relationship with risk of major bone fractures is uncertain. We aimed to investigate the association of baseline serum magnesium concentrations with risk of incident fractures. We analyzed data on 2245 men aged 42-61 years in the Kuopio Ischemic Heart Disease prospective cohort study, with the assessment of serum magnesium measurements and dietary intakes made at baseline. Hazard ratios [95% confidence intervals (CI)] for incident total (femoral, humeral, and forearm) and femoral fractures were assessed. During a median follow-up of 25.6 years, 123 total fractures were recorded. Serum magnesium was non-linearly associated with risk of total fractures. In age-adjusted Cox regression analysis, the hazard ratio (HR) (95% CIs) for total fractures in a comparison of the bottom quartile versus top quartile of magnesium concentrations was 2.10 (1.30-3.41), which persisted on adjustment for several established risk factors 1.99 (1.23-3.24). The association remained consistent on further adjustment for renal function, socioeconomic status, total energy intake, and several trace elements 1.80 (1.10-2.94). The corresponding adjusted HRs for femoral fractures were 2.56 (1.38-4.76), 2.43 (1.30-4.53) and 2.13 (1.13-3.99) respectively. There was no evidence of an association of dietary magnesium intake with risk of any fractures. In middle-aged Caucasian men, low serum magnesium is strongly and independently associated with an increased risk of fractures. Further research is needed to assess the potential relevance of serum magnesium in the prevention of fractures.

  19. Reliability and accuracy of digital templating for the humeral component of total shoulder arthroplasty.

    Science.gov (United States)

    Lee, Christopher S; Davis, Shane M; Lane, Christianne J; Koonce, Ryan C; Hartman, Andrew P; Ball, Kenneth; Esch, James C

    2015-01-01

    This experimental study evaluated the interobserver reliability and accuracy of pre-operative digital templating for humeral head size, stem size and neck angle for total shoulder arthroplasty. Twenty-five patients underwent a total shoulder arthroplasty with a single prosthesis. Four independent, blinded surgeons (two experienced shoulder surgeons and two PGY-6 fellows) used pre-operative radiographs and templating software to generate templates of the humeral head, stem and neck for each patient. Interobserver reliability was calculated using weighted kappa (κ) analysis. Accuracy was assessed by comparing templates to actual implant sizes. Interobserver reliability was fair to substantial (κ = 0.26 to 0.71) for head size, fair to substantial (κ = 0.39 to 0.72) for stem size and slight to fair (κ = 0.16 to 0.34) for neck angle. Templated head size, stem size and neck angle had accuracies of 53%, 77% and 68% within one size variation, respectively. Experience did not affect accuracy (p = 0.11 to 0.48). Digital templating is not a useful guide for pre-operative surgical planning and should not be used to select a prosthesis.

  20. Ultrasound Diagnosis of Either an Occult or Missed Fracture of an Extremity in Pediatric-Aged Children

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Kil Ho [Yeungnam University, Daegu (Korea, Republic of); Lee, Sung Moon [Keimyung University Dongsan Hospital, Daegu (Korea, Republic of); Lee, Young Hwan [Daegu Catholic University, Daegu (Korea, Republic of); Suh, Kyung Jin [Dongkuk University, Kyungju (Korea, Republic of)

    2010-02-15

    To report and assess the usefulness of ultrasound (US) findings for occult fractures of growing bones. For six years, US scans were performed in children younger than 15 years who were referred with trauma-related local pain and swelling of the extremities. As a routine US examination, the soft tissue, bones, and adjacent joints were examined in the area of discomfort, in addition to the asymptomatic contralateral extremity for comparison. Twenty-five occult fractures in 25 children (age range, five months-15 years; average age, 7.7 years) were confirmed by initial and follow-up radiograms, additional imaging studies, and clinical observation longer than three weeks. The most common site of occult fractures was the elbow (n = 9, 36%), followed by the knee (n = 7, 28%), ischium (n = 4, 16%), distal fibula (n = 3, 12%), proximal femur (n = 1, 4%), and humeral shaft (n = 1, 4%). On the retrograde review of the routine radiographs, 13 out of the 25 cases showed no bone abnormalities except for various soft tissue swelling. For the US findings, cortical discontinuity (direct sign of a fracture) was clearly visualized in 23 cases (92%) and was questionable in two (8%). As auxiliary US findings (indirect signs of a fracture), step-off deformities, tiny avulsed bone fragments, double-line appearance of cortical margins, and diffuse irregularity of the bone surfaces were identified. Performing US for soft tissue and bone surfaces with pain and swelling, with or without trauma history in the extremities, is important for diagnosing occult or missed fractures of immature bones in pediatric-aged children.

  1. AN EPIDEMIOLOGICAL SURVEY OF OSTEOPOROTIC FRACTURES IN OLDER RESIDENTS FROM THE MIDDLE URALS

    Directory of Open Access Journals (Sweden)

    E. N. Gladkova

    2014-01-01

    humeral fractures.

  2. Recombinant human parathyroid hormone (PTH 1-34) and low-intensity pulsed ultrasound have contrasting additive effects during fracture healing.

    Science.gov (United States)

    Warden, Stuart J; Komatsu, David E; Rydberg, Johanna; Bond, Julie L; Hassett, Sean M

    2009-03-01

    100 mW/cm(2) does not appear to be indicated in the management of closed, diaphyseal fractures.

  3. The percutaneous use of a pointed reduction clamp during intramedullary nailing of distal third tibial shaft fractures.

    Science.gov (United States)

    Forman, Jordanna M; Urruela, Adriana M; Egol, Kenneth A

    2011-12-01

    The purpose of this retrospective chart and radiographic review is to describe an effective reduction technique during intramedullary nailing of distal metaphyseal tibia fractures with the use of a pointed percutaneous clamp. Between 2007 and 2010, 100 patients who sustained 102 tibia fractures were definitively treated with an intramedullary nail at one of two medical centers. Diaphyseal fractures and injuries with an associated disruption of the distal tibiofibular joint were excluded from our study. A total of 27 patients with 27 distal metaphyseal tibia fractures (OTA types 42-A, 43-A, and 43-B) were included. All 27 patients underwent IM nailing of their fractures with anatomic reduction achieved using a percutaneously placed pointed reduction clamp prior to insertion of the IM implant. Fracture alignment and angular deformity was assessed using goniometric measurement functions on the PACS system (GE, Waukeshau, WI) obtained from preoperative and postoperative anteroposterior and lateral images for all subjects. Malalignment was defined as more than 5 degrees of angulation in any plane. Fourteen of the fractures were classified as OTA 42-A, 9 were OTA 43-A, and 4 were OTA 43-B. Analysis of post-closed reduction, preoperative anteroposterior radiographs revealed a mean of 7.9 degrees of coronal plane (range: 0.9 degrees-26 degrees) angulation. Post closed reduction preoperative lateral radiographs revealed a mean of 6.8 degrees sagittal plane (range: 0 degrees-24.6 degrees) angulation. Postoperative anteroposterior and lateral radiographs showed the distal segment returned to its anatomical alignment with a mean angulation of 0.5 degrees (range, 0 degrees-3.5 degrees) and 0.7 degrees (range, 0 degrees-4.2 degrees) of varus/ valgus and apex anterior/posterior angulation, respectively. These results showed an acceptable postopertative alignment in all 27 distal third fractures. No intra-operative or postoperative complications were noted in the study group. This

  4. Application of CT three-dimensional reconstruction in elbow injury

    International Nuclear Information System (INIS)

    Liang Wenhua; Qian Li

    2009-01-01

    Objective: To investigate the application of multi-slice spiral CT in fracture of elbow, and to study the value of different methods of the reconstruction. Methods: Thin line cross-section spiral CT scan was carried out in 13 cases with elbow injury, three-dimensional reconstruction was completed later. Several reconstructed image quality to display f the elbow fracture and dislocation were analyzed and compared. Results: 13 cases (17) elbow trauma included humeral media epicondyle fracture, humeral external epicondyle fracture, intercondylar fracture, olecranal fracture and radial head fracture. Among them, X-ray film showed negative in three sites, showed suspect fractures in 2 cases, and only showed single fracture in 2 cases. MPR reconstruction image could not only identify the diagnosis of fracture, but also provide further multi-angle display on fracture line and the extent of articular surface involvement. Surface reconstruction technology could exclude the impact of passive elbow flexion and display elbow injury more intuitively. Conclusion The elbow fracture dislocation could be showed clearly in multi-slice spiral CT, especially for complex fractures, with unmatched advantages compared to X-ray for clinical diagnosis and treatment determination. (authors)

  5. Hybrid external fixation in high-energy elbow fractures: a modular system with a promising future.

    Science.gov (United States)

    Lerner, A; Stahl, S; Stein, H

    2000-12-01

    Severe, high-energy, periarticular elbow injuries producing a "floating joint" are a major surgical challenge. Their reconstruction and rehabilitation are not well documented. Therefore, the following reports our experience with treating such injuries caused by war wounds. Seven adults with compound open peri- and intra-articular elbow fractures were treated in hybrid ring tubular fixation frames. After debridement, bone stabilization, and neurovascular reconstructions, early controlled daily movements were started in the affected joint. These seven patients had together seven humeral, five radial, and six ulnar fractures. All fractures united at a median time of 180 days. No deep infection developed. The functional end results assessed by the Khalfayan functional score were excellent in two, good in one, and fair in four of these severely mangled upper extremities. None was amputated. The Mangled Extremity Severity Score has been shown to be unable to provide a reliable assessment for severe high-energy limb injuries surgically managed with the modular hybrid thin wire tubular external fixation system. This hybrid system is a very useful addition to the surgical armamentarium of orthopedic trauma surgeons. It both allows complex surgical reconstructions and reduces the incidence of deep infections in these heavily contaminated injuries. The hybrid circular (thin wire) external fixation system is very modular and may provide secure skeletal stabilization even in cases of severely comminuted juxta-articular fractures on both sides of the elbow joint (floating elbow) with severe damage to soft tissues. This fixation system allows individual fixation of forearm bone fractures, thus allowing the preservation of pronation-supination movements.

  6. The difference in the appearance of proximal humeral epiphyseal ossification center on chest radiograph between the preterm and full-term infants

    International Nuclear Information System (INIS)

    Park, Hee Hong; Kim, Seung Cheol; Chang, Young Pyo; Park, Jin Young; Kwon, Ho Jang; Lee, Jee Young; Yoo, Dong Soo; Kim, You Me; Jeong, Chun Keun; Lee, Young Seok

    1997-01-01

    To assess the difference in the appearance of the proximal humeral epiphyseal ossification center, as seen on chest radiograph, between preterm and full-term infants at the same corrected ages. Forty two preterm infants born at 26--35 weeks of gestational age and 218 normal full-term infants born at 38-42 weeks were investigated. Because of various perinatal problems, the preterm infants were treated at a neonatal intensive care unit. Proximal humeral epiphyseal ossification centers were evaluated from chest radiographs, and in cases of preterm infants, the corrected age of 0 month was defined as postconceptional 40 weeks. In preterm infants, the numbers of chest radiographs obtained were 42 at 0 month, 40 at 1 month, 37 at 2 months and 36 at 3 months of corrected age, while in those who were full-term, the numbers were 103 cases at 0 month, 42 at 1 month, 42 at 2 months and 31 at 3 months of age In the preterm group, alkaline phosphatase, calcium, phosphorus levels and simple wrist radiographs were checked. We then evaluated the difference of appearance of the proximal humeral epiphyseal ossification center between preterm and full-term infants at the same corrected ages, as well as the difference between causative diseases, between the normal and abnormal serologic group and between the normal and abnormal wrist group in preterm infants at the same corrected ages. Using Fisher's exact test, the data were analysed. The incidences of the proximal humeral epiphyseal ossification center in preterm infants were 2.4% (1/42) at 0 month, 20.0% (8/40) at 1 month, 43.2% (16/37) at 2 months and 69.4%(25/36) at 3 months; in full-term infants, the figures were 24.3% (25/103) at 0 month, 66.7%(28/42) at 1 month, 83.3% (35/42) at 2 months and 90.3% (28/31) at 3 months. At 0, 1, and 2 months, the incidences were thus seen to be lower in preterm than in full-term infants(p 0.05). In preterm infants, there were no statistical differences between causative diseases, between the

  7. The normal development of proximal humeral epiphyseal ossification center in the first 2 years of life

    International Nuclear Information System (INIS)

    Kim, Seung Cheol

    1998-01-01

    The purpose of this study is to ascertain the normal maturation of proximal epiphyseal ossification centers by monthly age during the first years of life. The distribution of age was 0 to 24 months. Six hundred and seventy-five infants were male and 436 were female; their ages were measured in months, and there was no evidence of developmental problems. Proximal humeral epiphyseal ossification centers were evaluated from chest radiographs ; if not visualized, they were graded as 0, and otherwise, as follows : grade 1 : visualized with poor margin or a diameter of less than 1/4 of metaphyseal width; grade 2: visualized with good margin or a diameter of more than 1/4 of metaphyseal width; in grade 3 and 4, two ossification centers were visualized. Grade 3 indicated that one ossification center had the morphology of grade 2. Grade 5 indicated that two ossification centers were fused. We then assessed the relationship between the development of an ossification center and monthly age. A proximal humeral epiphyseal ossification center shows regular maturational features according to monthly age. 6 refs., 2 tabs., 5 figs

  8. Unstable intertrochanteric femur fractures in geriatric patients treated with the DLT trochanteric nail.

    Science.gov (United States)

    Temiz, Aytun; Durak, Aslihan; Atici, Teoman

    2015-07-01

    To evaluate clinical-functional and radiological results of geriatric patients with unstable intertrochanteric femur fracture treated with intramedullary nail. Thirty-two patients treated with intramedullary nail (DLT trochanteric nail) due to unstable intertrochanteric femur fractures were reviewed retrospectively. Fractures 31-A2 and 31-A3 (AO classification) were evaluated. Operation time, blood loss, and blood transfusion requirements, hospitalization period, time to fracture union were evaluated and perioperative and postoperative complications were recorded. According to the modified Baumgaertner criteria fracture reduction was analyzed radiologically, and nail tip-apex distance was measured. Femoral neck-shaft angle was also evaluated. Harris Hip Score for clinical evaluation and Kyo criteria for walking capacity were used. The mean age was 72 years (65-81), mean follow up time was 18.3 months (12-26). Nineteen patients had type 31-A2 and 13 had type 31-A3 fractures. Mean operation time was 36.3min (25-45), blood loss 185.9ml (100-250). Blood transfusion was required in 7 patients. The average hospitalization duration was 6 days (4-14) while the time to surgery from admission was 2.9 days (2-6). Radiologically, in 21 of the cases fracture reduction was well (65.6%), acceptable in 9 (28.1%), and poor in 2 (6.3%). In early postoperative period, the mean collo-diaphyseal angle was 129.1° (120-140°), mean tip-apex distance was 15.5mm (10-27). The mean Harris Hip Score was 63.4 (38-90). Two patients (6.3%) had excellent, 21 patients (65.6%) had good, 7 patients (21.8%) had moderate, and 2 patients (6.3%) had poor results. Walking capacity in the last follow-up in 20 of the cases (62.5%) was pre-fracture level. While complications were observed in seventeen patients (53.1%) (5 superficial wound infections, 5 fractures of the greater trochanter, 3 cases of secondary varus angulation and 4 cases of heterotopic ossification) none of them required additional surgery

  9. Surgical management of medial humeral epicondylitis, cubital synovial osteochondromatosis and humeroradial subluxation in a cat

    Directory of Open Access Journals (Sweden)

    Karen L Perry

    2017-02-01

    Full Text Available Case summary A 13-year-old domestic shorthair cat presented for evaluation of pain and difficulty ambulating. Orthopedic examination and CT facilitated a diagnosis of bilateral elbow synovial osteochondromatosis with medial humeral epicondylitis and concurrent osteoarthritis. Right humeroradial subluxation was evident on CT images, but no instability was evident preoperatively. Surgical treatment was elected, including external neurolysis of the ulnar nerve, removal of the areas of mineralization within the flexor carpi ulnaris muscle and medial arthrotomy to remove intra-articular mineralized bodies. Following closure, instability of the right elbow was noted with humeroradial subluxation necessitating placement of circumferential suture prostheses to provide satisfactory stability. Reassessment was performed 2, 6, 12, 24 and 40 weeks postoperatively and revealed maintenance of elbow stability and substantial improvement in mobility and comfort. Relevance and novel information While humeroradial subluxation has been reported in association with medial humeral epicondylitis on post-mortem examination, associated clinically significant instability has not been documented previously. Surgeons should be aware of the potential for this complication and check elbow stability following surgery. Despite this complication, a favorable medium-term outcome was achieved for this cat.

  10. Comparison of the effects of dexketoprofen trometamol, meloxicam and diclofenac sodium on fibular fracture healing, kidney and liver: an experimental rat model.

    Science.gov (United States)

    Inal, Sermet; Kabay, Sahin; Cayci, M Kasim; Kuru, H Isa; Altikat, Sayit; Akkas, Gizem; Deger, Aysenur

    2014-03-01

    Nonsteroidal anti-inflammatory drugs (NSAIDs) are particularly used in patients with bone fractures, but there are limited studies on whether one NSAID is superior to another. In this study, we used histopathological and biochemical parameters to determine whether there are differences between the effects of the administration of clinical doses of dexketoprofen trometamol (DEXT), meloxicam (MEL) and diclofenac sodium (DIC) on the healing of closed fibular fractures and the toxicity of both the liver and kidney. Twenty-eight male Sprague-Dawley rats were randomly divided into four groups of seven each. Closed diaphyseal fractures were formed in the left fibulas of all of the rats. The NSAIDs dexketoprofen trometamol (DEXT) (Arveles(®)), meloxicam (MEL) (Melox(®)) and diclofenac sodium (DIC) (Voltaren(®)) were intramuscularly administered to Groups I, II, and III, respectively, for a period of 10 days after the fibular fractures were performed. No pharmacological agents were administered to Group IV (Control group). Blood samples were collected from all of the rats after the fractures were performed, and the rats were sacrificed on day 28. The histopathological findings were compared, and the blood samples were evaluated to determine any differences between the levels of superoxide dismutase (SOD), catalase (CAT), and malondialdehyde (MDA). Our results suggest that DEXT and MEL impair the healing of bone fractures and that DIC does not histopathologically affect the healing process of bone fractures. We also found that DEXT, MEL, and DIC impaired the renal histopathology compared with the control group. However, the liver histopathological analysis showed that DEXT and MEL caused a higher degree of parenchymal necrosis compared with DIC. Based on our results, DIC can be considered a relatively safe medication in patients with fractures. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Single versus double row suture anchor fixation for greater tuberosity fractures - a biomechanical study.

    Science.gov (United States)

    Seppel, Gernot; Saier, Tim; Martetschläger, Frank; Plath, Johannes E; Guevara-Alvarez, Alberto; Henschel, Julia; Winkler, Martin; Augat, Peter; Imhoff, Andreas B; Buchmann, Stefan

    2017-12-01

    Fractures of the humeral greater tuberosity (GT) are a frequent injury progressively treated with arthroscopic suture anchor repair. Yet, no biomechanical study has been performed comparing fixation strength of arthroscopic single- (SR) vs. double row (DR) fixation. Standardized fractures of the greater tuberosity were created in 12 fresh frozen proximal humeri. After random assignation to the SR or DR group the fixed humeri were tested applying cyclic loading to the supraspinatus and infraspinatus tendon. Load to failure and fragment displacement were assessed by means of an electrodynamic material testing machine using an optical tracking system. Load to failure values were higher in the DR group (649 N; ±176) than in the SR group (490 N; ±145) however without statistical significance (p = .12). In greater tuberosity displacement of 3-5 mm surgical treatment is recommended. The fixing constructs in this study did not reach displacement landmarks of 3 or 5 mm before construct failure as shown in previous studies. Thus the applied traction force (N) at 1 mm displacement was analyzed. In the SR group the load at 1 mm displacement was 277 N; ±46 compared to 260 N; ±62 in the DR group (p = .65). The results suggest that both techniques are viable options for refixation of greater tuberosity fractures. Laboratory study.

  12. Nonunited humerus shaft fractures treated by external fixator augmented by intramedullary rod

    Directory of Open Access Journals (Sweden)

    Mahmoud A El-Rosasy

    2012-01-01

    Full Text Available Background: Nonunion of humeral shaft fractures after previously failed surgical treatment presents a challenging therapeutic problem especially in the presence of osteoporosis, bone defect, and joint stiffness. It would be beneficial to combine the use of external fixation technique and intramedullary rod in the treatment of such cases. The present study evaluates the results of using external fixator augmented by intramedullary rod and autogenous iliac crest bone grafting (ICBG for the treatment of humerus shaft nonunion following previously failed surgical treatment. Materials and Methods: Eighteen patients with atrophic nonunion of the humeral shaft following previous implant surgery with no active infection were included in the present study. The procedure included exploration of the nonunion, insertion of intramedullary rod (IM rod, autogenous ICBG and application of external fixator for compression. Ilizarov fixator was used in eight cases and monolateral fixator in ten cases. The monolateral fixator was preferred for females and obese patients to avoid abutment against the breast or chest wall following the use of Ilizarov fixator. The fixator was removed after clinical and radiological healing of the nonunion, but the IM rod was left indefinitely. The evaluation of results included both bone results (union rate, angular deformity and limb shortening and functional outcome using the University of California, Los Angeles (UCLA rating scale. Results: The mean follow-up was 35 months (range 24 to 52 months. Bone union was obtained in all cases. The functional outcome was satisfactory in 15 cases (83% and unsatisfactory in 3 cases (17% due to joint stiffness. The time to bone healing averaged 4.2 months (range 3 to 7 months. The external fixator time averaged 4.5 months (range 3.2 to 8 months. Superficial pin tract infection occurred in 39% (28/72 of the pins. No cases of nerve palsy, refracture, or deep infection were encountered

  13. Evaluation of periprosthetic bone mineral density and postoperative migration of humeral head resurfacing implants

    DEFF Research Database (Denmark)

    Mechlenburg, Inger; Klebe, Thomas Martin; Døssing, Kaj Verner

    2014-01-01

    BACKGROUND: Implant migration, bone mineral density (BMD), length of glenohumeral offset (LGHO), and clinical results were compared for the Copeland (Biomet Inc, Warsaw, IN, USA) and the Global C.A.P. (DePuy Int, Warsaw, IN, USA) humeral head resurfacing implants (HHRIs). METHODS: The study...... improved over time for both implant groups (P migration and good clinical results. Periprosthetic BMD and LGHO both increased for the Copeland HHRI more than for the Global C.A.P HHRI....

  14. 3D atlas-based registration can calculate malalignment of femoral shaft fractures in six degrees of freedom.

    Science.gov (United States)

    Crookshank, Meghan C; Beek, Maarten; Hardisty, Michael R; Schemitsch, Emil H; Whyne, Cari M

    2014-01-01

    This study presents and evaluates a semi-automated algorithm for quantifying malalignment in complex femoral shaft fractures from a single intraoperative cone-beam CT (CBCT) image of the fractured limb. CBCT images were acquired of complex comminuted diaphyseal fractures created in 9 cadaveric femora (27 cases). Scans were segmented using intensity-based thresholding, yielding image stacks of the proximal, distal and comminuted bone. Semi-deformable and rigid affine registrations to an intact femur atlas (synthetic or cadaveric-based) were performed to transform the distal fragment to its neutral alignment. Leg length was calculated from the volume of bone within the comminution fragment. The transformations were compared to the physical input malalignments. Using the synthetic atlas, translations were within 1.71 ± 1.08 mm (medial/lateral) and 2.24 ± 2.11 mm (anterior/posterior). The varus/valgus, flexion/extension and periaxial rotation errors were 3.45 ± 2.6°, 1.86 ± 1.5° and 3.4 ± 2.0°, respectively. The cadaveric-based atlas yielded similar results in medial/lateral and anterior/posterior translation (1.73 ± 1.28 mm and 2.15 ± 2.13 mm, respectively). Varus/valgus, flexion/extension and periaxial rotation errors were 2.3 ± 1.3°, 2.0 ± 1.6° and 3.4 ± 2.0°, respectively. Leg length errors were 1.41 ± 1.01 mm (synthetic) and 1.26 ± 0.94 mm (cadaveric). The cadaveric model demonstrated a small improvement in flexion/extension and the synthetic atlas performed slightly faster (6 min 24 s ± 50 s versus 8 min 42 s ± 2 min 25 s). This atlas-based algorithm quantified malalignment in complex femoral shaft fractures within clinical tolerances from a single CBCT image of the fractured limb.

  15. Percutaneous internal fixation of proximal fifth metatarsal jones fractures (Zones II and III) with Charlotte Carolina screw and bone marrow aspirate concentrate: an outcome study in athletes.

    Science.gov (United States)

    Murawski, Christopher D; Kennedy, John G

    2011-06-01

    Internal fixation is a popular first-line treatment method for proximal fifth metatarsal Jones fractures in athletes; however, nonunions and screw breakage can occur, in part because of nonspecific fixation hardware and poor blood supply. To report the results from 26 patients who underwent percutaneous internal fixation with a specialized screw system of a proximal fifth metatarsal Jones fracture (zones II and III) and bone marrow aspirate concentrate. Case series; Level of evidence, 4. Percutaneous internal fixation for a proximal fifth metatarsal Jones fracture (zones II and III) was performed on 26 athletic patients (mean age, 27.47 years; range, 18-47). All patients were competing at some level of sport and were assessed preoperatively and postoperatively using the Foot and Ankle Outcome Score and SF-12 outcome scores. The mean follow-up time was 20.62 months (range, 12-28). Of the 26 fractures, 17 were traditional zone II Jones fractures, and the remaining 9 were zone III proximal diaphyseal fractures. The mean Foot and Ankle Outcome Score significantly increased, from 51.15 points preoperatively (range, 14-69) to 90.91 at final follow-up (range, 71-100; P fracture healing on standard radiographs was 5 weeks after surgery (range, 4-24). Two patients did not return to their previous levels of sporting activity. One patient experienced a delayed union, and 1 healed but later refractured. Percutaneous internal fixation of proximal fifth metatarsal Jones fractures, with a Charlotte Carolina screw and bone marrow aspirate concentrate, provides more predictable results while permitting athletes a return to sport at their previous levels of competition, with few complications.

  16. Review of fixation techniques for the four-part fractured proximal humerus in hemiarthroplasty

    Directory of Open Access Journals (Sweden)

    Lorenzetti Silvio

    2011-07-01

    Full Text Available Abstract Introduction The clinical outcome of hemiarthroplasty for proximal humeral fractures is not satisfactory. Secondary fragment dislocation may prevent bone integration; the primary stability by a fixation technique is therefore needed to accomplish tuberosity healing. Present technical comparison of surgical fixation techniques reveals the state-of-the-art approach and highlights promising techniques for enhanced stability. Method A classification of available fixation techniques for three- and four part fractures was done. The placement of sutures and cables was described on the basis of anatomical landmarks such as the rotator cuff tendon insertions, the bicipital groove and the surgical neck. Groups with similar properties were categorized. Results Materials used for fragment fixation include heavy braided sutures and/or metallic cables, which are passed through drilling holes in the bone fragments. The classification resulted in four distinct groups: A: both tuberosities and shaft are fixed together by one suture, B: single tuberosities are independently connected to the shaft and among each other, C: metallic cables are used in addition to the sutures and D: the fragments are connected by short stitches, close to the fragment borderlines. Conclusions A plurality of techniques for the reconstruction of a fractured proximal humerus is found. The categorisation into similar strategies provides a broad overview of present techniques and supports a further development of optimized techniques. Prospective studies are necessary to correlate the technique with the clinical outcome.

  17. Steroid injections in the treatment of humeral unicameral bone cysts: long-term follow-up and review of the literature.

    Science.gov (United States)

    Pavone, V; Caff, G; Di Silvestri, C; Avondo, S; Sessa, G

    2014-05-01

    Retrospective evaluation of long-term effectiveness of the steroid injections treatment in patients with unicameral bone cysts (UBC). From January 1993 to April 2005, 23 children affected by proximal humeral UBC were evaluated according to the Neer-Cole classification system and treated with serial methylprednisolone acetate's injections. The patients were followed up at 1, 3, 6 and 12 months and then every year until the adolescence. After treatment, in 15 out of 23 patients (65.2%), the humeral cysts were referred, respectively, as Grade 1 and in four as Grade 2. In 4 patients, a refracture occurred. Statistical analysis showed an overall good response in 82.6% of patients at the end of the follow-up. Minor complication including skin discoloration accounted for 13.04%. The steroid injections showed to be an alternative excellent treatment for UBC, with complete healing of the lesions in the majority of cases. This procedure is not expensive, mini-invasive, with low surgical risk and short hospitalization.

  18. Exposed versus buried wires for fixation of lateral humeral condyle fractures in children: a comparison of safety and efficacy.

    Science.gov (United States)

    Chan, Lester Wai Mon; Siow, Hua Ming

    2011-10-01

    Displaced fractures of the lateral condyle of the humerus are usually treated with open reduction and fixation with smooth Kirschner wires. These may be passed through the skin and left exposed or buried subcutaneously. Exposed wires may be removed in the outpatient clinic, whereas buried wires require a formal procedure under anaesthesia. This advantage may be offset if there is a higher rate of complications with exposed wires. The aim of this study was to compare the safety and efficacy of exposed and buried wires. Retrospective cohort. Children with lateral condyle fractures of the humerus who had undergone surgery were identified from our departmental database. Case records and X-rays of 75 patients were reviewed. Forty-two patients had buried wires and 33 had exposed wires. There were no serious complications in either group. In the exposed wires group, 1 patient had a superficial wound infection that was treated effectively with 1 week of oral antibiotics, while 2 patients had hypergranulation of pin tracts treated with topical silver nitrate. None of the patients showed loss of reduction, deep infection, or any other complications requiring additional procedures. There was no statistically significant difference in the rate of complications between the buried and exposed groups. We conclude that open reduction and exposed wiring is a safe and effective option for lateral condyle fractures, and recommend a period of 4 weeks of K-wire fixation followed by 2 weeks of backslab immobilisation as adequate for union with minimal risk of infection.

  19. Humeral avulsion of the anterior shoulder stabilizing structures after anterior shoulder dislocation: demonstration by MRI and MR arthrography

    International Nuclear Information System (INIS)

    Tirman, P.F.J.; Steinbach, L.S.; Feller, J.F.; Stauffer, A.E.

    1996-01-01

    Objective. To demonstrate the MRI findings of an anterior shoulder capsular avulsion from the humerus, with or without subscapularis rupture, after anterior dislocation or severe abduction external rotation injury. Design and patients. We retrospectively reviewed the MRI and MR arthrographic examinations of seven patients who were identified at surgery with avulsion of the anterior shoulder stabilizers from the humerus. MRI was correlated with clinical history and surgical results. Results. MRI findings included: inhomogeneity or frank disruption of the anterior capsule at the humeral insertion (all), fluid intensity anterior to the shoulder (six patients), tear of the subscapularis tendon (six patients), dislocation of the biceps tendon (four patients), and a Hill-Sachs deformity (four patients). MR arthrography additionally found extravasation of contrast through the capsular defect (two patients). Conclusions. Our findings suggest that MRI is helpful for diagnosing humeral avulsion of the anterior glenohumeral capsule, especially when a tear of the subscapularis tendon insertion is present. MR arthrography may be of benefit for diagnosing capsular avulsion without associated subscapularis tendon abnormality. (orig.). With 4 figs

  20. Cementless anatomical prosthesis for the treatment of 3-part and 4-part proximal humerus fractures: cadaver study and prospective clinical study with minimum 2 years followup

    Directory of Open Access Journals (Sweden)

    Obert Laurent

    2016-01-01

    Full Text Available Introduction: The purpose of this study was to evaluate the functional and radiological outcomes of a cementless, trauma-specific locked stem for 3- and 4-part proximal humeral fractures. Materials and methods: This study consisted of two parts: a cadaver study with 22 shoulders and a multicenter prospective clinical study of 23 fracture patients evaluated at least 2 years after treatment. In the cadaver study, the locked stem (HumelockTM, FX Solutions and its instrumentation were evaluated. In the clinical study, five senior surgeons at four different hospitals performed the surgical procedures. An independent surgeon evaluated the patients using clinical (Constant score, QuickDASH and radiological (X-rays, CT scans outcome measures. Results: The cadaver study allowed us to validate the height landmarks relative to the pectoralis major tendon. In the clinical study, at the review, abduction was 95° (60–160, forward flexion was 108° (70–160, external rotation (elbow at body was 34° (0–55, the QuickDASH was 31 (4.5–59, the overall Constant score was 54 (27–75, and the weighted Constant score was 76 (31.5–109. Discussion: This preliminary study of hemiarthroplasty (HA with a locked stem found results that were at least equivalent to published series. As all patients had at least a 2-year follow-up, integration of the locked stem did not cause any specific complications. These results suggest that it is possible to avoid using cement when hemiarthroplasty is performed for the humeral stem. This implant makes height adjustment and transosseous suturing of the tuberosities more reproducible.

  1. Diaphyseal sequestration of the metacarpal and metatarsal bone in cattle

    International Nuclear Information System (INIS)

    Hirsbrunner, G.; Steiner, A.; Martig, J.

    1995-01-01

    Between 1990 and 1993 ten cows with diaphyseal sequestration of the metacarpal or metatarsal bone were brought to the Clinic for Food Animals and Horses, University of Bern. History, clinical and radiographic findings at admission, therapy, and clinical and radiographic short- and longterm results were evaluated retrospectively. Six animals had a history of trauma. The metatarsal bone (n = 9) was much more frequently affected than the metacarpal bone (n = 1). Lameness was slight in seven cases and intermediate in three cases. Soft tissue swelling was present in all cases, and fistula formation in eight cases. Sequestrectomy was performed in nine cases, the exuberant new bone circumferentially removed in three of these cases, and the skin primarily closed in all nine cases treated surgically. One animal with a small sequestrum, showing no fistula formation, was treated conservatively. Four to 44 months after surgery, interviews with the owners by telephone revealed that the recovery had been satisfactory in all ten cases. At the same time period, clinical and radiographic examinations of the six animals that were still alive were performed by a veterinarian additionally. Normal limb function had been restored in all six animals, although the affected limb was clearly distinctable from the unaffected contralateral limb, because of its increased diameter. From the results of this study we concluded that longterm prognosis after sequestrectomy is favourable; primary wound closure can be attempted with good success. Cosmetically promising results, however, can only be achieved, if sequestrectomy is performed early enough in the course of the disease or if the exuberant new bone is surgically removed

  2. Falls and comorbidity

    DEFF Research Database (Denmark)

    Jørgensen, Terese Sara Høj; Hansen, Annette Højmann; Sahlberg, Marie

    2014-01-01

    AIMS: To compare nationwide time trends and mortality in hip and proximal humeral fractures; to explore associations between incidences of falls risk related comorbidities (FRICs) and incidence of fractures. METHODS: The study is a retrospective cohort study using nationwide Danish administrative....... CONCLUSIONS: The results suggest that the overall reduction in fractures can be explained by reduction in falls related comorbidity....

  3. Author Details

    African Journals Online (AJOL)

    Outcome of plate osteosynthesis in the management of proximal humeral fractures in adults. Abstract PDF · Vol 6, No 1 (2012) - Articles Management of Acute Musculoskeletal Pain: A Review Abstract PDF · Vol 7, No 1 (2013) - Articles Early weight-bearing after ankle fracture fixation: a prospective randomized and ...

  4. Interest in the glenoid hull method for analyzing humeral subluxation in primary glenohumeral osteoarthritis.

    Science.gov (United States)

    Bouacida, Soufyane; Gauci, Marc-Olivier; Coulet, Bertrand; Lazerges, Cyril; Cyteval, Catherine; Boileau, Pascal; Chammas, Michel

    2017-07-01

    Posterior humeral subluxation is the main cause of failure of total shoulder arthroplasty. We aimed to compare humeral head subluxation in various reference planes and to search for a correlation with retroversion, inclination, and glenoid wear. We included 109 computed tomography scans of primary glenohumeral osteoarthritis and 97 of shoulder problems unrelated to shoulder osteoarthritis (controls); all computed tomography scans were reconstructed in the anatomic scapular plane and the glenoid hull plane that we defined. In both planes, we measured retroversion, inclination, glenohumeral offset (Walch index), and scapulohumeral offset. Retroversion in the scapular plane (Friedman method) was lower than that in the glenoid hull plane for controls and for arthritic shoulders. The threshold of scapulohumeral subluxation was 60% and 65% in the scapular plane and glenoid hull plane, respectively. The mean upward inclination was lower in the scapular plane (Churchill method) than in the glenoid hull plane (Maurer method). In the glenoid hull plane, 35% of type A2 glenoids showed glenohumeral offset greater than 75%, with mean retroversion of 25.6° ± 6° as compared with 7.5° ± 7.2° for the "centered" type A2 glenoids (P hull plane and r = 0.59 in the scapular plane (P hull plane may be more accurate than in the scapular plane. Thus, the glenoid hull method allows for better understanding type B3 of the modified Walch classification. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  5. Early experience with titanium elastic nails in a trauma unit.

    LENUS (Irish Health Repository)

    Shah, M H

    2012-02-03

    The Titanium Elastic Nail (TEN) offers a number of potential advantages over traditional ways of treating long bone fractures particularly in the paediatric population. These advantages include earlier mobilisation and shorter hospital stay and less risk of loss of fracture position. These advantages are most apparent and significant when treating femoral fractures in children where the length of hospital stay is reduced from several weeks to a typical period of 5 to 8 days. We have reviewed our early experience of using these implants over the past 2 years. Patients were assessed clinically and radiologically. 13 patients were treated using the TEN during this period. There were 2 femoral fractures, 4 humeral fractures, 1 tibial and 6 forearm fractures treated using the Titanium Elastic Nail. All fractures united during the study period. However 1 humeral fracture required a secondary bone grafting and plating for delayed union and 1 fracture lost position during follow-up. Insertion point pain was a problem in 4 patients but this resolved after nail removal in all. There was 1 superficial wound infection which resolved with antibiotics and 1 superficial wound infection of an open fracture wound which resolved following nail removal and antibiotics. There were no cases of deep infection. There were no limb length discrepancy or rotational or angular malalignment problems. Biomechanical principles and technical aspects of this type of fixation are discussed.

  6. Reconstruction of large diaphyseal bone defect by simplified bone transport over nail technique: A 7-case series.

    Science.gov (United States)

    Ferchaud, F; Rony, L; Ducellier, F; Cronier, P; Steiger, V; Hubert, L

    2017-11-01

    Reconstruction of large diaphyseal bone defect is complex and the complications rate is high. This study aimed to assess a simplified technique of segmental bone transport by monorail external fixator over an intramedullary nail.A prospective study included 7 patients: 2 femoral and 5 tibial defects. Mean age was 31years (range: 16-61years). Mean follow-up was 62 months (range: 46-84months). Defects were post-traumatic, with a mean length of 7.2cm (range: 4 to 9.5cm). For 3 patients, reconstruction followed primary failure. In 4 cases, a covering flap was necessary. Transport used an external fixator guided by an intramedullary nail, at a rate of 1mm per day. One pin was implanted on either side of the distraction zone. The external fixator was removed 1 month after bone contact at the docking site. Mean bone transport time was 11 weeks (range: 7-15 weeks). Mean external fixation time was 5.1months (range: 3.5 to 8months). Full weight-bearing was allowed 5.7months (range: 3.5-13months) after initiation of transport. In one patient, a pin had to be repositioned. In 3 patients, the transported segment re-ascended after external fixatorablation, requiring repeat external fixation and resumption of transport. There was just 1 case of superficial pin infection. Reconstruction quality was considered "excellent" on the Paley-Marr criteria in 6 cases. The present technique provided excellent reconstruction quality in 6 of the 7 cases. External fixation time was shorter and resumption of weight-bearing earlier than with other reconstruction techniques, notably including bone autograft, vascularized bone graft or the induced membrane technique. Nailing facilitated control of limb axis and length. The complications rate was 50%, comparable to other techniques. This study raises the question of systematic internal fixation of the docking site, to avoid any mobilization of the transported segment. The bone quality, axial control and rapidity shown by the present technique make

  7. Anatomy and histology of the transverse humeral ligament.

    Science.gov (United States)

    Snow, Brian J; Narvy, Steven J; Omid, Reza; Atkinson, Roscoe D; Vangsness, C Thomas

    2013-10-01

    The classic literature describes the transverse humeral ligament (THL) as a distinct anatomic structure with a role in biceps tendon stability; however, recent literature suggests that it is not a distinct anatomic structure. The purpose of this study was to evaluate the gross and microscopic anatomy of the THL, including a specific investigation of the histology of this ligament. Thirty frozen, embalmed cadaveric specimens were dissected to determine the gross anatomy of the THL. Seven specimens were evaluated histologically for the presence of mechanoreceptors and free nerve endings. Two tissue layers were identified in the area described as the THL. In the deep layer, fibers of the subscapularis tendon were found to span the bicipital groove with contributions from the coracohumeral ligament and the supraspinatus tendon. Superficial to this layer was a fibrous fascial covering consisting of distinct bands of tissue. Neurohistology staining revealed the presence of free nerve endings but no mechanoreceptors. This study's findings demonstrate that the THL is a distinct structure continuous with the rotator cuff tendons and the coracohumeral ligament. The finding of free nerve endings in the THL suggests a potential role as a shoulder pain generator. Copyright 2013, SLACK Incorporated.

  8. Early Conversion of External Fixation to Interlocked Nailing in Open Fractures of Both Bone Leg Assisted with Vacuum Closure (VAC) - Final Outcome.

    Science.gov (United States)

    Gill, Simrat Pal Singh; Raj, Manish; Kumar, Sunil; Singh, Pulkesh; Kumar, Dinesh; Singh, Jasveer; Deep, Akash

    2016-02-01

    Management of compound grade III fractures of both bone leg includes external stabilization for long period, followed by various soft tissue coverage procedures. Primary interlocking of tibia had been also done with variable results. External fixation for long time without any bone loss often leads to infected nonunion, loss of reduction, pin tract infection and failure of fixation, primary interlocking in compound grade III fractures had shown high medullary infection rate. We managed all cases of compound grade III A/B fractures with primary external fixation, simultaneous wound management using vacuum assisted closure (VAC) followed by early conversion to interlocking within 2 weeks of fixator application. To determine the effectiveness of vacuum assisted closure (VAC) for the early conversion of external fixator to definitive interlocking in open fractures of the both bone leg. In current study we selected 84 cases of compound grade IIIA/B diaphyseal fractures of both bone leg during period of May 2010 to September 2013. We managed these cases by immediate debridement and application of external fixation followed by repeated debridement, application of vacuum assisted closure (VAC) and conversion to interlocking within two weeks. Out of 84 cases union was achieved in 80(95%) of cases with definitive tibial interlocking. Excellent to good result were obtained in 77(91.8%) of cases and fair to poor result seen in rest of 7(8.2%) of cases according to modified Ketenjian's criteria. 5 out of these 7 poor result group cases were from Compound Grade III B group to start with. Deep infection rate in our series were 7% i.e. total 6 cases and 4 out of these were from compound Grade III B group to start with. Vacuum assisted closure (VAC) give a good help for rapid closure of the wound and help in early conversion to definitive intramedullary nailing. Reamed nail could well be used in compound grade IIIA/B fractures without increasing the risk of infection. It gives

  9. Delayed fracture healing and increased callus adiposity in a C57BL/6J murine model of obesity-associated type 2 diabetes mellitus.

    Directory of Open Access Journals (Sweden)

    Matthew L Brown

    Full Text Available INTRODUCTION: Impaired healing and non-union of skeletal fractures is a major public health problem, with morbidity exacerbated in patients with diabetes mellitus (DM. DM is prevalent worldwide and affects approximately 25.8 million US adults, with >90% having obesity-related type 2 DM (T2DM. While fracture healing in type 1 DM (T1DM has been studied using animal models, an investigation into delayed healing in an animal model of T2DM has not yet been performed. METHODS: Male C57BL/6J mice at 5 weeks of age were placed on either a control lean diet or an experimental high-fat diet (HFD for 12 weeks. A mid-diaphyseal open tibia fracture was induced at 17 weeks of age and a spinal needle was used for intra-medullary fixation. Mice were sacrificed at days 7, 10, 14, 21, 28, and 35 for micro-computed tomography (μCT, histology-based histomorphometry and molecular analyses, and biomechanical testing. RESULTS: HFD-fed mice displayed increased body weight and impaired glucose tolerance, both characteristic of T2DM. Compared to control mice, HFD-fed mice with tibia fractures showed significantly (p<0.001 decreased woven bone at day 28 by histomorphometry and significantly (p<0.01 decreased callus bone volume at day 21 by μCT. Interestingly, fracture calluses contained markedly increased adiposity in HFD-fed mice at days 21, 28, and 35. HFD-fed mice also showed increased PPARγ immunohistochemical staining at day 14. Finally, calluses from HFD-fed mice at day 35 showed significantly (p<0.01 reduced torsional rigidity compared to controls. DISCUSSION: Our murine model of T2DM demonstrated delayed fracture healing and weakened biomechanical properties, and was distinctly characterized by increased callus adiposity. This suggests altered mesenchymal stem cell fate determination with a shift to the adipocyte lineage at the expense of the osteoblast lineage. The up-regulation of PPARγ in fracture calluses of HFD-fed mice is likely involved in the proposed

  10. Humeral retroversion and shoulder rotational mobility in young handball practitioners.

    Science.gov (United States)

    Quadros, Gustavo Aguiar; Döhnert, Marcelo Baptista

    2015-01-01

    : To evaluate the prevalence of humeral retroversion and rotational mobility (RHH) in young handball practitioners and non-practitioners. : This is a cross-sectional study performed with two groups: the handball group, with 14 female students practicing handball and the control group, with 13 young participants non-practicing pitch sports. : The handball group presented full rotational movement (FRM) hi-gher than the control group in both the dominant shoulder (p=0.001) and the non-dominant shoulder (p=0.0001). The mobility of active and passive internal rotation was significantly higher in handball players in both shoulders. The handball group presented lower internal rotation range of motion for the dominant shoulder as compared to the non-dominant shoul-der (p=0.001). : Young handball practitioners, des-pite skeletally immature, showed a higher MRT than the control group. The handball group showed loss of internal rotation (medial) on the dominant shoulder as compared to the non--dominant shoulder. Level of Evidence II, Prospective Study.

  11. Technical note: the humeral canal approach to the brachial plexus.

    LENUS (Irish Health Repository)

    Frizelle, H P

    2012-02-03

    Many variations to the axillary approach to the brachial plexus have been described. However, the success rate varies depending on the approach used and on the definition of success. Recent work describes a new approach to regional anaesthesia of the upper limb at the humeral\\/brachial canal using selective stimulation of the major nerves. This report outlines initial experience with this block, describing the technique and results in 50 patients undergoing hand and forearm surgery. All patients were assessed for completeness of motor and sensory block. The overall success rate was 90 percent. Motor block was present in 80 percent of patients. Completion of the block was necessary in 5 patients. Two patients required general anaesthesia. The preponderance of ulnar deficiencies agrees with previously published data on this technique. No complications were described. Initial experience confirms the high success rate described using the Dupre technique. This technically straightforward approach with minimal complications can be recommended for regional anaesthesia of the upper limb.

  12. In vivo biomechanical evaluation of a novel angle-stable interlocking nail design in a canine tibial fracture model.

    Science.gov (United States)

    Déjardin, Loïc M; Cabassu, Julien B; Guillou, Reunan P; Villwock, Mark; Guiot, Laurent P; Haut, Roger C

    2014-03-01

    To compare clinical outcome and callus biomechanical properties of a novel angle stable interlocking nail (AS-ILN) and a 6 mm bolted standard ILN (ILN6b) in a canine tibial fracture model. Experimental in vivo study. Purpose-bred hounds (n = 11). A 5 mm mid-diaphyseal tibial ostectomy was stabilized with an AS-ILN (n = 6) or an ILN6b (n = 5). Orthopedic examinations and radiographs were performed every other week until clinical union (18 weeks). Paired tibiae were tested in torsion until failure. Callus torsional strength and toughness were statistically compared and failure mode described. Total and cortical callus volumes were computed and statistically compared from CT slices of the original ostectomy gap. Statistical significance was set at P dogs (P dogs by 10 weeks and in 3/5 ILN6b dogs at 18 weeks. Callus mechanical properties were significantly greater in AS-ILN than ILN6b specimens by 77% (failure torque) and 166% (toughness). Failure occurred by acute spiral (control and AS-ILN) or progressive transverse fractures (ILN6b). Cortical callus volume was 111% greater in AS-ILN than ILN6b specimens (P < .05). Earlier functional recovery, callus strength and remodeling suggest that the AS-ILN provides a postoperative biomechanical environment more conducive to bone healing than a comparable standard ILN. © Copyright 2014 by The American College of Veterinary Surgeons.

  13. Reliability of internal oblique elbow radiographs for measuring displacement of medial epicondyle humerus fractures: a cadaveric study.

    Science.gov (United States)

    Gottschalk, Hilton P; Bastrom, Tracey P; Edmonds, Eric W

    2013-01-01

    Standard elbow radiographs (AP and lateral views) are not accurate enough to measure true displacement of medial epicondyle fractures of the humerus. The amount of perceived displacement has been used to determine treatment options. This study assesses the utility of internal oblique radiographs for measurement of true displacement in these fractures. A medial epicondyle fracture was created in a cadaveric specimen. Displacement of the fragment (mm) was set at 5, 10, and 15 in line with the vector of the flexor pronator mass. The fragment was sutured temporarily in place. Radiographs were obtained at 0 (AP), 15, 30, 45, 60, 75, and 90 degrees (lateral) of internal rotation, with the elbow in set positions of flexion. This was done with and without radio-opaque markers placed on the fragment and fracture bed. The 45 and 60 degrees internal oblique radiographs were then presented to 5 separate reviewers (of different levels of training) to evaluate intraobserver and interobserver agreement. Change in elbow position did not affect the perceived displacement (P=0.82) with excellent intraobserver reliability (intraclass correlation coefficient range, 0.979 to 0.988) and interobserver agreement of 0.953. The intraclass correlation coefficient for intraobserver reliability on 45 degrees internal oblique films for all groups ranged from 0.985 to 0.998, with interobserver agreement of 0.953. For predicting displacement, the observers were 60% accurate in predicting the true displacement on the 45 degrees internal oblique films and only 35% accurate using the 60 degrees internal oblique view. Standardizing to a 45 degrees internal oblique radiograph of the elbow (regardless of elbow flexion) can augment the treating surgeon's ability to determine true displacement. At this degree of rotation, the measured number can be multiplied by 1.4 to better estimate displacement. The addition of a 45 degrees internal oblique radiograph in medial humeral epicondyle fractures has good

  14. Titanium and steel fracture fixation plates with different surface topographies: Influence on infection rate in a rabbit fracture model.

    Science.gov (United States)

    Metsemakers, W J; Schmid, Tanja; Zeiter, Stephan; Ernst, Manuela; Keller, Iris; Cosmelli, Nicolo; Arens, Daniel; Moriarty, T Fintan; Richards, R Geoff

    2016-03-01

    Implant-related infection is a challenging complication in musculoskeletal trauma surgery. In the present study, we examined the role of implant material and surface topography as influencing factors on the development of infection in an experimental model of plating osteosynthesis in the rabbit. The implants included in this experimental study were composed of: standard Electropolished Stainless Steel (EPSS), standard titanium (Ti-S), roughened stainless steel (RSS) and surface polished titanium (Ti-P). Construct stability and load-to-failure of Ti-P implants was compared to that of Ti-S implants in a rabbit cadaveric model. In an in vivo study, a rabbit humeral fracture model was used. Each rabbit received one of three Staphylococcus aureus inocula, aimed at determining the infection rate at a low, medium and high dose of bacteria. Outcome measures were quantification of bacteria on the implant and in the surrounding tissues, and determination of the infectious dose 50 (ID50). No significant differences were observed between Ti-S and Ti-P regarding stiffness or failure load in the cadaver study. Of the 72 rabbits eventually included in the in vivo study, 50 developed an infection. The ID50 was found to be: EPSS 3.89×10(3) colony forming units (CFU); RSS 8.23×10(3) CFU; Ti-S 5.66×10(3) CFU; Ti-P 3.41×10(3) CFU. Significantly lower bacterial counts were found on the Ti-S implants samples compared with RSS implants (ptitanium and steel implants with conventional or modified topographies. Ti-P implants, which have previously been shown in preclinical studies to reduce complications associated with tissue adherence, do not affect infection rate in this preclinical fracture model. Therefore, Ti-P implants are not expected to affect the infection rate, or influence implant stability in the clinical situation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. The Floating Upper Limb: Multiple Injuries Involving Ipsilateral, Proximal, Humeral, Supracondylar, and Distal Radial Limb.

    Science.gov (United States)

    Manaan, Qazi; Bashir, Adil; Zahoor, Adnan; Mokhdomi, Taseem A; Danish, Qazi

    2016-09-01

    Floating arm injury represents a common yet complicated injury of the childhood severely associated with limb deformation and even morbidity, if not precisely addressed and credibly operated. Here, we report a rare floating upper limb case of a 9-year-old boy with multiple injuries of ipsilateral proximal humeral, supracondylar and distal radial limb. This is the first report to document such a combined floating elbow and floating arm injury in the same limb. In this report, we discuss the surgical procedures used and recovery of the patient monitored to ascertain the effectiveness of the method in limb reorganisation.

  16. Orthopaedic resident preparedness for closed reduction and pinning of pediatric supracondylar fractures is improved by e-learning: a multisite randomized controlled study.

    Science.gov (United States)

    Hearty, Thomas; Maizels, Max; Pring, Maya; Mazur, John; Liu, Raymond; Sarwark, John; Janicki, Joseph

    2013-09-04

    There is a need to provide more efficient surgical training methods for orthopaedic residents. E-learning could possibly increase resident surgical preparedness, confidence, and comfort for surgery. Using closed reduction and pinning of pediatric supracondylar humeral fractures as the index case, we hypothesized that e-learning could increase resident knowledge acquisition for case preparation in the operating room. An e-learning surgical training module was created on the Computer Enhanced Visual Learning platform. The module provides a detailed and focused road map of the procedure utilizing a multimedia format. A multisite prospective randomized controlled study design compared residents who used a textbook for case preparation (control group) with residents who used the same textbook plus completed the e-learning module (test group). All subjects completed a sixty-question test on the theory and methods of the case. After completion of the test, the control group then completed the module as well. All subjects were surveyed on their opinion regarding the effectiveness of the module after performing an actual surgical case. Twenty-eight subjects with no previous experience in this surgery were enrolled at four academic centers. Subjects were randomized into two equal groups. The test group scored significantly better (p < 0.001) and demonstrated competence on the test compared with the control group; the mean correct test score (and standard deviation) was 90.9% ± 6.8% for the test group and 73.5% ± 6.4% for the control group. All residents surveyed (n = 27) agreed that the module is a useful supplement to traditional methods for case preparation and twenty-two of twenty-seven residents agreed that it reduced their anxiety during the case and improved their attention to surgical detail. E-learning using the Computer Enhanced Visual Learning platform significantly improved preparedness, confidence, and comfort with percutaneous closed reduction and pinning of a

  17. Functional outcome of diaphyseal fractures of femur managed by ...

    African Journals Online (AJOL)

    nail offers the added advantages of early joint mobilization, early weight bearing, early muscle rehabilitation, shortened hospital stay, and ... one of the principal load-bearing bones in the lower extremity ..... rotational stability and axial length.

  18. Construction of computational models for the stress analysis of the bones using CT imaging: application in the gleno-humeral joint

    International Nuclear Information System (INIS)

    Cisilino, Adrian; D'Amico, Diego; Buroni, Federico; Commisso, Pablo; Sammartino, Mario; Capiel, Carlos

    2008-01-01

    A methodology for the construction of computational models from CT images is presented in this work. Computational models serve for the stress analysis of the bones using the Finite Element Method. The elastic constants of the bone tissue are calculated using the density data obtained in from the CTs. The proposed methodology is demonstrated in the construction of a model for the gleno-humeral joint. (authors) [es

  19. Torsional and axial compressive properties of tibiotarsal bones of red-tailed hawks (Buteo jamaicensis).

    Science.gov (United States)

    Kerrigan, Shannon M; Kapatkin, Amy S; Garcia, Tanya C; Robinson, Duane A; Guzman, David Sanchez-Migallon; Stover, Susan M

    2018-04-01

    OBJECTIVE To describe the torsional and axial compressive properties of tibiotarsal bones of red-tailed hawks (Buteo jamaicensis). SAMPLE 16 cadaveric tibiotarsal bones from 8 red-tailed hawks. PROCEDURES 1 tibiotarsal bone from each bird was randomly assigned to be tested in torsion, and the contralateral bone was tested in axial compression. Intact bones were monotonically loaded in either torsion (n = 8) or axial compression (8) to failure. Mechanical variables were derived from load-deformation curves. Fracture configurations were described. Effects of sex, limb side, and bone dimensions on mechanical properties were assessed with a mixed-model ANOVA. Correlations between equivalent torsional and compressive properties were determined. RESULTS Limb side and bone dimensions were not associated with any mechanical property. During compression tests, mean ultimate cumulative energy and postyield energy for female bones were significantly greater than those for male bones. All 8 bones developed a spiral diaphyseal fracture and a metaphyseal fissure or fracture during torsional tests. During compression tests, all bones developed a crushed metaphysis and a fissure or comminuted fracture of the diaphysis. Positive correlations were apparent between most yield and ultimate torsional and compressive properties. CONCLUSIONS AND CLINICAL RELEVANCE The torsional and axial compressive properties of tibiotarsal bones described in this study can be used as a reference for investigations into fixation methods for tibiotarsal fractures in red-tailed hawks. Although the comminuted and spiral diaphyseal fractures induced in this study were consistent with those observed in clinical practice, the metaphyseal disruption observed was not and warrants further research.

  20. Protocol for the ProFHER (PROximal Fracture of the Humerus: Evaluation by Randomisation trial: a pragmatic multi-centre randomised controlled trial of surgical versus non-surgical treatment for proximal fracture of the humerus in adults

    Directory of Open Access Journals (Sweden)

    Maffulli Nicola

    2009-11-01

    Full Text Available Abstract Background Proximal humeral fractures, which occur mainly in older adults, account for approximately 4 to 5% of all fractures. Approximately 40% of these fractures are displaced fractures involving the surgical neck. Management of this group of fractures is often challenging and the outcome is frequently unsatisfactory. In particular it is not clear whether surgery gives better outcomes than non-surgical management. Currently there is much variation in the use of surgery and a lack of good quality evidence to inform this decision. Methods/Design We aim to undertake a pragmatic UK-based multi-centre randomised controlled trial evaluating the effectiveness and cost-effectiveness of surgical versus standard non-surgical treatment for adults with an acute closed displaced fracture of the proximal humerus with involvement of the surgical neck. The choice of surgical intervention is left to the surgeon, who must use techniques that they are fully experienced with. This will avoid 'learning curve' problems. We will promote good standards of non-surgical care, similarly insisting on care-provider competence, and emphasize the need for comparable provision of rehabilitation for both groups of patients. We aim to recruit 250 patients from a minimum of 18 NHS trauma centres throughout the UK. These patients will be followed-up for 2 years. The primary outcome is the Oxford Shoulder Score, which will be collected via questionnaires completed by the trial participants at 6, 12 and 24 months. This is a 12-item condition-specific questionnaire providing a total score based on the person's subjective assessment of pain and activities of daily living impairment. We will also collect data for other outcomes, including general health measures and complications, and for an economic evaluation. Additionally, we plan a systematic collection of reasons for non-inclusion of eligible patients who were not recruited into the trial, and their baseline

  1. Assessment of the risk factors for impending fractures following radiotherapy for long bone metastases using CT scan-based virtual simulation: a retrospective study

    International Nuclear Information System (INIS)

    Tatar, Zuzana; Soubrier, Martin; Dillies, Anne Françoise; Verrelle, Pierre; Boisgard, Stéphane; Lapeyre, Michel

    2014-01-01

    Radiotherapy for long bone metastases (RTLB) can be complicated by fractures, which considerably increase morbidity and mortality. The aim of this study was to analyze the risk factors for impending fractures following radiotherapy for long bone metastases (RTLB) using CT scan-based virtual simulation. Forty-seven (47) patients were treated with RTLB (18 lung, 11 breast, 10 prostate and 8 other cancers) for a period of 18 months. Two doctors analyzed the CT images prior to radiation therapy. The impending fractures were then monitored and the correlation between bone scan parameters and fracture occurrence was analyzed. The male gender ratio was 0.57 and the mean age 62.8 (33–93) years. The average size of the metastatic lesions was 32 (8–87) x 2 (6–81) x 52 (7–408) mm with cortical involvement (CI) in 66% of cases. The site was in the upper third of the bone in 92% of cases (28 femoral, 17 humeral and two tibial). Ten fractures occurred: two during RTLB, seven after one month and one after 6.6 months. The fractured lesions measured 48 (17–87) x 34 (12–66) x 76 (38–408) mm. The predictive parameters for fracture were osteolytic (39% vs. 10%; p = 0.02) and permeative lesions (42% vs. 0%; p < 0.0005), a Mirels score ≥9 (42% vs. 0%; p < 0.0005), circumferential CI ≥30% (71% vs. 0%, p < 0.00001), CI ≥45 mm in height (67% vs. 0%, p < 0.00001) and CI in thickness =100% (40% vs. 0%; p = 0.0008). In the multivariate analysis, circumferential CI ≥30% was the only predictive parameter for fracture (p = 0.00035; OR = 62; CI 95%: 6.5-595). Overall survival was 91% and 40% at one month and twelve months respectively. Prophylactic primary fixation surgery should always be considered when the circumferential CI ≥30%

  2. Eficacia del tratamiento acupuntural en pacientes con epicondilitis humeral externa

    Directory of Open Access Journals (Sweden)

    Ida Pantoja Fornés

    2015-07-01

    Full Text Available Se realizó una intervención terapéutica en 100 pacientes de 20-59 años, con epicondilitis humeral externa, atendidos en la Sala de Rehabilitación del Policlínico Comunitario Docente “Eduardo Mesa Llull”, del municipio de II Frente, de la provincia Santiago de Cuba, desde septiembre de 2013 hasta marzo de 2014, para evaluar la eficacia del tratamiento acupuntural en ellos. La muestra fue dividida en 2 grupos de 50 integrantes cada uno, seleccionados de forma aleatoria. Los del grupo de estudio fueron tratados con acupuntura más corriente Trabert y los del control con corriente Trabert solamente. Como principales resultados predominaron: el grupo etario de 40-49 años (64,0 %, el sexo femenino (66,0 % y los obreros de servicio (56,0 %. Se obtuvo que los tratados con acupuntura tuvieron una mejor evolución, de donde se infiere que la terapia empleada resultó efectiva para aliviar el dolor en quienes se aplicó

  3. Avascular necrosis of femoral and humeral heads in a HIV (+) patient

    International Nuclear Information System (INIS)

    Ubysz, R.; Wojtycha-Kwasnica, B.; Higersberger, J.

    2004-01-01

    Osteonecrosis (AVN-avascular necrosis) has been reported to occur occasionally among HIV-infected patient. The number of incidences appears to be rising. The hip is most commonly involved and often bilaterally. Osteonecrosis occurred more frequently in case of those patients who used systemically corticosteroids or testosterone, with hiperlipidemia, alcoholism and immune reconstruction. Case Report: A 28- year - old man, presented with a 2-years history of pain involving both hip joints and shoulders. Over the following weeks the pain was progressive. The patient had a history of HIV for 10 years before. He had a history of steroid use due to cerebellitis (3 years before). No other manifestations of AIDS was presented. The radiographs and CT examination presented irregular areas of increased endosteal density and with fragmentation femoral and humeral heads. Osteonecrosis in HIV (+) patients is most commonly associated with steroid use. HIV infected patients with persistent joints pain should be evaluated for this serious complication. Plain radiographs and TK examination help to establish the diagnosis. (author)

  4. Attrition tendinitis of long head of biceps brachii in relation to humeral head osteonecrosis: case report.

    Science.gov (United States)

    Wiesler, Ethan R; Sarlikiotis, Thomas; Mavrogenis, Andreas F; Kokkalis, Zinon T

    2013-01-01

    This case report identifies a 41-year-old male patient who developed anterior shoulder pain in the setting of humeral head osteonecrosis. As a consequence of the cartilage degeneration, multiple loose bodies formed and migrated into the bicipital tendon sheath, causing attrition tendinitis, which was a feature of the clinical presentation. The patient was treated by a combination of arthroscopic glenohumeral joint debridement and open tenodesis of the biceps using a suture anchor. Follow-up revealed asymptomatic shoulder function by 18 months. This is the first report in the literature of bicipital tendinitis in the context of avascular necrosis of the shoulder.

  5. Ultrasound assessment of the posterior circumflex humeral artery in elite volleyball players: Aneurysm prevalence, anatomy, branching pattern and vessel characteristics

    OpenAIRE

    van de Pol, Daan; Maas, Mario; Terpstra, Aart; Pannekoek-Hekman, Marja; Alaeikhanehshir, Sena; Kuijer, P. Paul F. M.; Planken, R. Nils

    2016-01-01

    Objectives To determine the prevalence of posterior circumflex humeral artery (PCHA) aneurysms and vessel characteristics of the PCHA and deep brachial artery (DBA) in elite volleyball players. Methods Two-hundred and eighty players underwent standardized ultrasound assessment of the dominant arm by a vascular technologist. Assessment included determination of PCHA aneurysms (defined as segmental vessel dilatation ?150 %), PCHA and DBA anatomy, branching pattern, vessel course and diameter. R...

  6. A Critical Review on Prosthetic Features Available for Reversed Total Shoulder Arthroplasty

    Directory of Open Access Journals (Sweden)

    Bart Middernacht

    2016-01-01

    Full Text Available Reversed total shoulder arthroplasty is a popular treatment in rotator cuff arthropathy and in displaced proximal humeral fractures in elderly. In 2016, 29 models of commercially available designs express this popularity. This study describes all the different design parameters available on the market. Prosthetic differences are found for the baseplate, glenosphere, polyethylene, and humeral component and these differences need to be weighed out carefully for each patient knowing that a gain in one mechanical parameter can balance the loss of another. Patient specific implants may help in the future.

  7. Predictive factors for functional outcome and failure in angular stable osteosynthesis of the proximal humerus.

    LENUS (Irish Health Repository)

    Hardeman, Francois

    2012-02-01

    Angular stable osteosynthesis has become the gold standard in the operative treatment of proximal humeral fractures. The aim of this article is to determine the indications for osteosynthesis versus primary arthroplasty based on clinical and radiological parameters.

  8. A new scale measuring translation of the humeral head as a prognostic factor for the treatment of large and massive rotator cuff tears.

    Science.gov (United States)

    Taniguchi, Noboru; D'Lima, Darryl D; Suenaga, Naoki; Chosa, Etsuo

    2018-02-01

    Failure rates after rotator cuff repair remain high in patients with massive tears. Although superior translation of the humeral head has been used to assess the severity of rotator cuff tears, the relevance of anterior migration of the humeral head to clinical outcomes has not been established. The purpose of this study was to investigate the potential role of the T-scale, a measure of the anterolateral translation of the humeral head, as a prognostic factor for rotator cuff repair. One hundred twenty consecutive patients with full-thickness rotator cuff tears underwent primary rotator cuff repair. The T-scale and acromiohumeral interval (AHI) were measured preoperatively on axial computed tomography scans and radiographs, respectively. The correlations of the T-scale and AHI with previously published scores and active forward elevation (FE) were investigated. The outcome of rotator cuff repairs was compared between patients with positive and patients with negative preoperative T-scale values. The preoperative T-scale but not AHI correlated significantly with postoperative FE and clinical scores in patients with large to massive tears but not in those with small to medium tears. Postoperative FE and clinical scores were significantly higher in patients with positive T-scale values than in those with negative T-scale values. The relative risk of retear was 2.0 to 7.9 times greater in patients with negative T-scale values. Patients with large to massive tears and negative T-scale values had poorer clinical outcomes and higher retear rates. A negative T-scale value represents a useful prognostic factor for considering reverse shoulder arthroplasty in patients at greater risk of retear after rotator cuff repair. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  9. Humeral metastasis from a sacrococcygeal chordoma: a case report

    Directory of Open Access Journals (Sweden)

    Sepidbakht Sepideh

    2011-08-01

    Full Text Available Abstract Introduction Chordomas are rare tumors of the skeletal system that arise from an intra-osseous benign precursor of notochordal cells. They are mainly locally aggressive. However, metastases to other sites, including the humeri, resulting in pathological fractures have been reported. We report the case of a patient with a metastatic chordoma that produced a pathologic fracture of the humerus. Case presentation We report the case of a 60-year-old Iranian woman who presented with a fracture of her right humerus following a minor trauma. She had a history of a sacrococcygeal chordoma. Histological and immunohistochemical studies of the fracture site suggested the diagnosis of a chordoma. Conclusions Chordoma is a rare tumor and rarely metastasizes, but it should be considered in the differential diagnosis of epithelioid bone tumors. The only current effective treatment for this type of tumor is carbon ion therapy. There is currently no effective medical therapy available for advanced chordoma, and this type of tumor is not very responsive to radiotherapy.

  10. Achondroplasia: Really rhizomelic?

    Science.gov (United States)

    Shelmerdine, Susan Cheng; Brittain, Helen; Arthurs, Owen J; Calder, Alistair D

    2016-08-01

    Achondroplasia is the most common form of short limb dwarfism in humans. The shortening of the limb lengths in achondroplasia is widely described as "rhizomelic." While this appearance may be convincing clinically, the description is not necessarily true or helpful radiologically. The aims of this study, were therefore, to determine whether rhizomelic shortening is a true feature of achondroplasia at diagnosis in infancy. Humeral, radial, femoral, and tibial diaphyseal lengths were recorded by two independent observers from 22 skeletal surveys of infants with achondroplasia and compared with 150 normal age-matched control subjects. Upper and lower limb bone length ratios (radial/humeral and tibial/femoral lengths, respectively) in both groups were compared using an unpaired t-test. Mean upper limb length ratios were statistically higher within the achondroplasia group at 0.87 ± 0.04 (n = 22, mean age 70 ± 94 days) compared to normal controls at 0.79 ± 0.02 (n = 150, mean age 113 days ± 88 days; P achondroplasia demonstrate statistically significant rhizomelic shortening within the upper limbs, but not lower limbs at diagnosis, compared to normal controls. The term "rhizomelic shortening" in relation to achondroplasia should be reserved when describing upper limb proportions. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  11. Distal radius fractures result in alterations in scapular kinematics: a three-dimensional motion analysis.

    Science.gov (United States)

    Ayhan, Cigdem; Turgut, Elif; Baltaci, Gul

    2015-03-01

    Scapular motion is closely integrated with arm motion. Injury to a distal segment requires compensatory changes in the proximal segments leading to alterations in scapular motion. Since the effects of distal injuries on scapular kinematics remain unknown, in the present study we investigated the influences on scapular motion in patients with distal injuries. Sixteen subjects with a history of distal radius fracture and 20 asymptomatic healthy subjects (controls) participated in the study. Three-dimensional scapular and humeral kinematic data were collected on all 3 planes of shoulder elevation: frontal, sagittal, and scapular. All testing was performed in a single session; therefore, the sensors remained attached to the participants for all testing. The position and orientation data of the scapula at 30°, 60°, 90°, and 120° humerothoracic elevation and 120°, 90°, 60°, and 30° lowering were used for statistical comparisons. Independent samples t-test was used to compare the scapular internal/external rotation, upward/downward rotation, and anterior/posterior tilt between the affected side of subjects with a distal radius fracture and the dominant side of asymptomatic subjects at the same stage of humerothoracic elevation. Scapular internal rotation was significantly increased at 30° elevation (P=0.01), 90° elevation (P=0.03), and 30° lowering (P=0.03), and upward rotation was increased at 30° and 60° elevation (Pplane elevation. Scapular upward rotation and anterior tilt were significantly increased during 30° lowering on both the scapular (P=0.002 and 0.02, respectively) and sagittal planes (P=0.01 and 0.02. respectively). Patients with distal radius fractures exhibit altered scapular kinematics, which may further contribute to the development of secondary musculoskeletal pathologies. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. The healing stages of an intramedullary implanted tibia: A stress strain comparative analysis of the calcification process

    Science.gov (United States)

    Filardi, Vincenzo

    2015-01-01

    Aims The extended usage of unreamed tibial nailing resulted in reports of an increased rate of complications, especially for the distal portion of the tibia. Unreamed nailing favours biology at the expense of the achievable mechanical stability, it is therefore of interest to define the limits of the clinical indications for this method. Extra-articular fractures of the distal tibial metaphysis, meta-diaphyseal junction, and adjacent diaphysis are distinct in their management from impaction derived ‘‘pilon’’ type fractures and mid-diaphyseal fractures. The goals of this work were to gain a thorough understanding of the load-sharing mechanism between unreamed nail and bones in a fractured tibia. With this purpose a complete model of the human leg was realised, simulating a mid-diaphyseal fracture, classified as A2 type 1, according to the AO classification. The analysis of the entire chain allows to have a complete picture of the stress distribution and of the most stressed bones and soft tissues, but, more importantly can overcome problems connected with boundary conditions imposed at single bony components. Methods Model consists of six bony structures: pelvis, femur, patella, fibula, tibia, and a simplified lump of the feet, configured in a standing up position. Their articular cartilage layers, were simulated by 3D membranes of opportune stiffness connecting the different segments. Moreover an unreamed intra-medullary nail Expert Tibial Nail (DePuy Synthes®) stabilized the fractured tibia. A load of 700 N has been applied at the top of pelvis and a part the feet, at the tip, was rigidly fixed. Five different contact interfaces have been imposed at the different bony surfaces in contact. Results Three different conditions were analysed: the initially healthy tibia, the A2 type 1 fractured tibia with the Expert tibial nail implanted, and the follow up stage after complete healing of tibia. Non-linear finite element analysis of the models were performed

  13. Biomechanical Comparison of 3 Inferiorly Directed Versus 3 Superiorly Directed Locking Screws on Stability in a 3-Part Proximal Humerus Fracture Model.

    Science.gov (United States)

    Donohue, David M; Santoni, Brandon G; Stoops, T Kyle; Tanner, Gregory; Diaz, Miguel A; Mighell, Mark

    2018-06-01

    To quantify the stability of 3 points of inferiorly directed versus 3 points of superiorly directed locking screw fixation compared with the full contingent of 6 points of locked screw fixation in the treatment of a 3-part proximal humerus fracture. A standardized 3-part fracture was created in 10 matched pairs (experimental groups) and 10 nonmatched humeri (control group). Osteosynthesis was performed using 3 locking screws in the superior hemisphere of the humeral head (suspension), 3 locking screws in the inferior hemisphere (buttress), or the full complement of 6 locking screws (control). Specimens were tested in varus cantilever bending (7.5 Nm) to 10,000 cycles or failure. Construct survival (%) and the cycles to failure were compared. Seven of 10 controls survived the 10,000-cycle runout (70%: 8193 average cycles to failure). No experimental constructs survived the 10,000-cycle runout. Suspension and buttress screw groups failed an average of 331 and 516 cycles, respectively (P = 1.00). The average number of cycles to failure and the number of humeri surviving the 10,000-cycle runout were greater in the control group than in the experimental groups (P ≤ 0.006). Data support the use of a full contingent of 6 points of locking screw fixation over 3 superior or 3 inferior points of fixation in the treatment of a 3-part proximal humerus fracture with a locking construct. No biomechanical advantage to the 3 buttress or 3 suspension screws used in isolation was observed.

  14. A bi-articular model for scapular-humeral rhythm reconstruction through data from wearable sensors.

    Science.gov (United States)

    Lorussi, Federico; Carbonaro, Nicola; De Rossi, Danilo; Tognetti, Alessandro

    2016-04-23

    Patient-specific performance assessment of arm movements in daily life activities is fundamental for neurological rehabilitation therapy. In most applications, the shoulder movement is simplified through a socket-ball joint, neglecting the movement of the scapular-thoracic complex. This may lead to significant errors. We propose an innovative bi-articular model of the human shoulder for estimating the position of the hand in relation to the sternum. The model takes into account both the scapular-toracic and gleno-humeral movements and their ratio governed by the scapular-humeral rhythm, fusing the information of inertial and textile-based strain sensors. To feed the reconstruction algorithm based on the bi-articular model, an ad-hoc sensing shirt was developed. The shirt was equipped with two inertial measurement units (IMUs) and an integrated textile strain sensor. We built the bi-articular model starting from the data obtained in two planar movements (arm abduction and flexion in the sagittal plane) and analysing the error between the reference data - measured through an optical reference system - and the socket-ball approximation of the shoulder. The 3D model was developed by extending the behaviour of the kinematic chain revealed in the planar trajectories through a parameter identification that takes into account the body structure of the subject. The bi-articular model was evaluated in five subjects in comparison with the optical reference system. The errors were computed in terms of distance between the reference position of the trochlea (end-effector) and the correspondent model estimation. The introduced method remarkably improved the estimation of the position of the trochlea (and consequently the estimation of the hand position during reaching activities) reducing position errors from 11.5 cm to 1.8 cm. Thanks to the developed bi-articular model, we demonstrated a reliable estimation of the upper arm kinematics with a minimal sensing system suitable for

  15. Locking plate fixation provides superior fixation of humerus split type greater tuberosity fractures than tension bands and double row suture bridges.

    Science.gov (United States)

    Gaudelli, Cinzia; Ménard, Jérémie; Mutch, Jennifer; Laflamme, G-Yves; Petit, Yvan; Rouleau, Dominique M

    2014-11-01

    This paper aims to determine the strongest fixation method for split type greater tuberosity fractures of the proximal humerus by testing and comparing three fixation methods: a tension band with No. 2 wire suture, a double-row suture bridge with suture anchors, and a manually contoured calcaneal locking plate. Each method was tested on eight porcine humeri. A osteotomy of the greater tuberosity was performed 50° to the humeral shaft and then fixed according to one of three methods. The humeri were then placed in a testing apparatus and tension was applied along the supraspinatus tendon using a thermoelectric cooling clamp. The load required to produce 3mm and 5mm of displacement, as well as complete failure, was recorded using an axial load cell. The average load required to produce 3mm and 5mm of displacement was 658N and 1112N for the locking plate, 199N and 247N for the double row, and 75N and 105N for the tension band. The difference between the three groups was significant (Prow (456N) and tension band (279N) (Prow (71N/mm) and tension band (33N/mm) (Pbiomechanical fixation for split type greater tuberosity fractures. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. East and Central African Journal of Surgery - Vol 5, No 2 (2000)

    African Journals Online (AJOL)

    A comparison of the use of coaptation U-splintage and a Polypropylene brace for humeral shaft fractures · EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. I Kakande, AP Kidza, EK Naddumba, 7-10 ...

  17. Computed tomographic analysis of tibiotarsal bone mineral density and content in turkeys as influenced by age and sex

    International Nuclear Information System (INIS)

    Charuta, A.; Cooper, R.G.; Pierzchala, M.; Horbanczuk, J.O.

    2012-01-01

    Changes in the volumetric bone mineral density (vBMD) and bone mineral content (BMC) of tibiotarsal bones of growing turkeys as affected by birds' age, sex, and within-the-bone location, respectively, were determined by computed tomography. The research was performed on 165 heavy-type BIG 6 turkeys reared between weeks (wk) 3-16 of age. The computed tomography measurement, conducted at 18 and 50% of the bone length, comprised a bone fragment which was 0.07 mm thick for the compact and the spongious substance collectively. It should be noted that the diaphyses of the tibiotarsal bones in turkeys (580 mg/cubic cm) had significantly greater vBMD than the proximal metaphyses (300 mg/cubic cm). BMC was higher in metaphyses for both sexes. Significant differences between the BMC of the metaphyses and the diaphyses were observed in males and females at wk 3, 6 and 9, and at wk 3 and 12, respectively. vBMD in the diaphyses gradually attenuated with age for both sexes, from 688 mg/cubic cm (wk 3) to 532 mg/cubic cm (wk 16). vBMD of the metaphyses was constant in females, but in males it achieved maximum values of 350 mg/cubic cm at wk 6 and 12 and minimum of 260 mg/cubic cm at wk 9 and 16. Correlations between body weight and vBMD of the diaphyses were observed in males (r = -0.85, P less than 0.001) and females (r = -0.52, P less than 0.01). It can be concluded that vBMD loss in diaphyses diminished bone-breaking strength leading in investigated turkeys to deformities and bone fractures

  18. Scapular Resting Position and Gleno-Humeral Movement Dysfunction in Asymptomatic Racquet Players: A Case-Control Study.

    Science.gov (United States)

    Shimpi, Apurv P; Bhakti, Shah; Roshni, Karnik; Rairikar, Savita A; Shyam, Ashok; Sancheti, Parag K

    2015-12-01

    Racquet sports, especially lawn tennis and badminton have been gaining popularity in Asian countries like India. With this increase in popularity, the injury rate in the sport has also increased. The study will help detect the presence of gleno-humeral movement dysfunction and scapular resting position abnormality in asymptomatic racquet players, thus providing basis for screening the players and allow the clinician to determine if the asymmetry is a normal adaptation in the player or an abnormal change associated with injury. 46 asymptomatic professional players were divided into a study group of 23 players (16 tennis and 7 badminton) and control group of 23 football players. Assessment of passive gleno-humeral range of motion and distance of spine and inferior angle of scapula from corresponding spinous process were measured bilaterally and between groups. There was statistically significant reduction in range of internal rotation (62.17 ± 8.09), extension (39.78 ± 4.12) and an increase in the external rotation (106.95 ± 7.49) of dominant compared to non-dominant arm of racquet players and a statistically significant decrease in internal rotation (78.69 ± 10.24), extension (44.78 ± 3.19), adduction (37.39 ± 6.54) and an increase in external rotation (102.6 ± 5.19) of dominant arm of racquet players compared to football players. Study also showed statistically significant increase in the spino-scapular distance at the level of inferior angle of scapula (10.23 ± 1.43) on dominant side compared to non-dominant. The dominant side scapula of asymptomatic racquet players showed increased external rotation and elevation as compared to the non-dominant side. Also, reduced shoulder internal rotation, extension and adduction and gain in shoulder external rotation was observed on the dominant side of racquet players when compared to the control group.

  19. Effect of Random Natural Fractures on Hydraulic Fracture Propagation Geometry in Fractured Carbonate Rocks

    Science.gov (United States)

    Liu, Zhiyuan; Wang, Shijie; Zhao, Haiyang; Wang, Lei; Li, Wei; Geng, Yudi; Tao, Shan; Zhang, Guangqing; Chen, Mian

    2018-02-01

    Natural fractures have a significant influence on the propagation geometry of hydraulic fractures in fractured reservoirs. True triaxial volumetric fracturing experiments, in which random natural fractures are created by placing cement blocks of different dimensions in a cuboid mold and filling the mold with additional cement to create the final test specimen, were used to study the factors that influence the hydraulic fracture propagation geometry. These factors include the presence of natural fractures around the wellbore, the dimension and volumetric density of random natural fractures and the horizontal differential stress. The results show that volumetric fractures preferentially formed when natural fractures occurred around the wellbore, the natural fractures are medium to long and have a volumetric density of 6-9%, and the stress difference is less than 11 MPa. The volumetric fracture geometries are mainly major multi-branch fractures with fracture networks or major multi-branch fractures (2-4 fractures). The angles between the major fractures and the maximum horizontal in situ stress are 30°-45°, and fracture networks are located at the intersections of major multi-branch fractures. Short natural fractures rarely led to the formation of fracture networks. Thus, the interaction between hydraulic fractures and short natural fractures has little engineering significance. The conclusions are important for field applications and for gaining a deeper understanding of the formation process of volumetric fractures.

  20. Surgical anatomy of the radial nerve in the deltopectoral approach for revision shoulder arthroplasty and periprosthetic fracture fixation: a cadaveric study.

    Science.gov (United States)

    Fu, Michael C; Hendel, Michael D; Chen, Xiang; Warren, Russell F; Dines, David M; Gulotta, Lawrence V

    2017-12-01

    Radial nerve injury is a rare but clinically significant complication of revision shoulder arthroplasty and fixation of native and periprosthetic proximal humeral fractures. Understanding of the anatomic relationship between the radial nerve as it enters the humeral spiral groove and anterior shoulder landmarks in a deltopectoral approach is necessary to avoid iatrogenic radial nerve injury. Eight forequarter cadaveric specimens were dissected through a deltopectoral approach. Distances between the radial nerve entry into the proximal spiral groove and the coracoid process, distal lesser tuberosity/inferior subscapularis insertion, superior latissimus insertion, and inferior latissimus insertion were measured. Means, standard deviations, and ranges were determined for each distance. The radial nerve entry into the proximal spiral groove averaged 133.1 mm (range, 110.3-153.0 mm) from the coracoid process, 101.9 mm (range, 76.5-124.3 mm) from the distal lesser tuberosity/inferior subscapularis insertion, 81.0 mm (range, 63.4-101.5 mm) from the superior latissimus insertion, and 39.6 mm (range, 25.5-55.4 mm) from the inferior latissimus insertion. The proximal spiral groove was distal to the inferior latissimus insertion in all specimens. The risk of iatrogenic injury to the radial nerve at the spiral groove may be minimized through proper identification and protection or avoidance of circumferential fixation. However, if encircling fixation with cerclage cables is necessary, instrumentation proximal to the inferior edge of the latissimus dorsi insertion may reduce the risk of radial nerve injury. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  1. Autologous Concentrated Bone Marrow Grafting for the Treatment of Osteonecrosis of the Humeral Head: A Report of Five Shoulders in Four Cases

    Directory of Open Access Journals (Sweden)

    Takeshi Makihara

    2017-01-01

    Full Text Available Five shoulders in four patients affected by advanced osteonecrosis of the humeral head were treated with autologous concentrated bone marrow grafting. Bone marrow sample was aspirated from the iliac crests, concentrated by a centrifugation technique, and injected into the necrotic site. The shoulders were evaluated radiologically with X-ray scoring and clinically with measurement of range of motion and pain score (visual analogue scale, VAS. The mean follow-up period was 49.4 (range, 24–73 months. The concentration ratio of nucleated cells was calculated and the number of transplanted mesenchymal stem cells (MSC was estimated by a colony-forming assay. All four shoulders with stage 3 disease achieved joint sparing. One shoulder with stage 4 disease required replacement surgery. Clinical evaluation of the spared joints showed improvement in range of motion in two cases and deterioration in two cases. VAS scores were 0 after surgery in three cases. The mean concentration ratio was 2.73, and the mean number of transplanted MSC was 1125. The outcomes of autologous concentrated bone marrow grafting for advanced osteonecrosis of the humeral head were varied. Further research is needed to determine the effectiveness and the indications of the present surgery.

  2. Role of MRI in hip fractures, including stress fractures, occult fractures, avulsion fractures

    International Nuclear Information System (INIS)

    Nachtrab, O.; Cassar-Pullicino, V.N.; Lalam, R.; Tins, B.; Tyrrell, P.N.M.; Singh, J.

    2012-01-01

    MR imaging plays a vital role in the diagnosis and management of hip fractures in all age groups, in a large spectrum of patient groups spanning the elderly and sporting population. It allows a confident exclusion of fracture, differentiation of bony from soft tissue injury and an early confident detection of fractures. There is a spectrum of MR findings which in part is dictated by the type and cause of the fracture which the radiologist needs to be familiar with. Judicious but prompt utilisation of MR in patients with suspected hip fractures has a positive therapeutic impact with healthcare cost benefits as well as social care benefits.

  3. Paratrooper's ankle fracture: posterior malleolar fracture.

    Science.gov (United States)

    Young, Ki Won; Kim, Jin-su; Cho, Jae Ho; Kim, Hyung Seuk; Cho, Hun Ki; Lee, Kyung Tai

    2015-03-01

    We assessed the frequency and types of ankle fractures that frequently occur during parachute landings of special operation unit personnel and analyzed the causes. Fifty-six members of the special force brigade of the military who had sustained ankle fractures during parachute landings between January 2005 and April 2010 were retrospectively analyzed. The injury sites and fracture sites were identified and the fracture types were categorized by the Lauge-Hansen and Weber classifications. Follow-up surveys were performed with respect to the American Orthopedic Foot and Ankle Society ankle-hindfoot score, patient satisfaction, and return to preinjury activity. The patients were all males with a mean age of 23.6 years. There were 28 right and 28 left ankle fractures. Twenty-two patients had simple fractures and 34 patients had comminuted fractures. The average number of injury and fractures sites per person was 2.07 (116 injuries including a syndesmosis injury and a deltoid injury) and 1.75 (98 fracture sites), respectively. Twenty-three cases (41.07%) were accompanied by posterior malleolar fractures. Fifty-five patients underwent surgery; of these, 30 had plate internal fixations. Weber type A, B, and C fractures were found in 4, 38, and 14 cases, respectively. Based on the Lauge-Hansen classification, supination-external rotation injuries were found in 20 cases, supination-adduction injuries in 22 cases, pronation-external rotation injuries in 11 cases, tibiofibular fractures in 2 cases, and simple medial malleolar fractures in 2 cases. The mean follow-up period was 23.8 months, and the average follow-up American Orthopedic Foot and Ankle Society ankle-hindfoot score was 85.42. Forty-five patients (80.36%) reported excellent or good satisfaction with the outcome. Posterior malleolar fractures occurred in 41.07% of ankle fractures sustained in parachute landings. Because most of the ankle fractures in parachute injuries were compound fractures, most cases had to

  4. Effects of humeral head compression taping on the isokinetic strength of the shoulder external rotator muscle in patients with rotator cuff tendinitis

    OpenAIRE

    Kim, Moon-Hwan; Oh, Jae-Seop

    2015-01-01

    [Purpose] The purpose of this study was to examine the effects of humeral head compression taping (HHCT) on the strength of the shoulder external rotator muscle in patients with rotator cuff tendinitis. [Subjects and Methods] Twenty patients with rotator cuff tendinitis were recruited. The shoulder external rotator strength was measured using a Biodex isokinetic dynamometer system. A paired t-test was performed to evaluate within-group differences in the strength of the shoulder external rota...

  5. Fracture Mechanics

    International Nuclear Information System (INIS)

    Jang, Dong Il; Jeong, Gyeong Seop; Han, Min Gu

    1992-08-01

    This book introduces basic theory and analytical solution of fracture mechanics, linear fracture mechanics, non-linear fracture mechanics, dynamic fracture mechanics, environmental fracture and fatigue fracture, application on design fracture mechanics, application on analysis of structural safety, engineering approach method on fracture mechanics, stochastic fracture mechanics, numerical analysis code and fracture toughness test and fracture toughness data. It gives descriptions of fracture mechanics to theory and analysis from application of engineering.

  6. The humeral origin of the brachioradialis muscle: an unusual site of high radial nerve compression.

    Science.gov (United States)

    Cherchel, A; Zirak, C; De Mey, A

    2013-11-01

    Radial nerve compression is seldom encountered in the upper arm, and most commonly described compression syndromes have their anatomical cause in the forearm. The teres major, the triceps muscle, the intermuscular septum region and the space between the brachialis and brachioradialis muscles have all been identified as radial nerve compression sites above the elbow. We describe the case of a 38-year-old male patient who presented with dorso-lateral forearm pain and paraesthesias without neurological deficit. Surgical exploration revealed radial nerve compression at the humeral origin of the brachioradialis muscle. Liberation of the nerve at this site was successful at relieving the symptoms. To our knowledge, this compression site has not been described in the literature. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  7. Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures.

    Science.gov (United States)

    Röderer, Götz; Scola, Alexander; Schmölz, Werner; Gebhard, Florian; Windolf, Markus; Hofmann-Fliri, Ladina

    2013-10-01

    Proximal humerus fracture fixation can be difficult because of osteoporosis making it difficult to achieve stable implant anchorage in the weak bone stock even when using locking plates. This may cause implant failure requiring revision surgery. Cement augmentation has, in principle, been shown to improve stability. The aim of this study was to investigate whether augmentation of particular screws of a locking plate aimed at a region of low bone quality is effective in improving stability in a proximal humerus fracture model. Twelve paired human humerus specimens were included. Quantitative computed tomography was performed to determine bone mineral density (BMD). Local bone quality in the direction of the six proximal screws of a standard locking plate (PHILOS, Synthes) was assessed using mechanical means (DensiProbe™). A three-part fracture model with a metaphyseal defect was simulated and fixed with the plate. Within each pair of humeri the two screws aimed at the region of the lowest bone quality according to the DensiProbe™ were augmented in a randomised manner. For augmentation, 0.5 ml of bone cement was injected in a screw with multiple outlets at its tip under fluoroscopic control. A cyclic varus-bending test with increasing upper load magnitude was performed until failure of the screw-bone fixation. The augmented group withstood significantly more load cycles. The correlation of BMD with load cycles until failure and BMD with paired difference in load cycles to failure showed that augmentation could compensate for a low BMD. The results demonstrate that augmentation of screws in locked plating in a proximal humerus fracture model is effective in improving primary stability in a cyclic varus-bending test. The augmentation of two particular screws aimed at a region of low bone quality within the humeral head was almost as effective as four screws with twice the amount of bone cement. Screw augmentation combined with a knowledge of the local bone quality

  8. [Clinical observation on external humeral epicondylitis treated with back-rotation traction].

    Science.gov (United States)

    Fu, Rui-yang; Wang, Ya-ling; Gu, Zhong-zhong; Wang, Bao-hu; Zhu, Qi; Li, Ye; Wang, En-ping

    2009-02-01

    To evaluate the clinical effect of manipulation on external humeral epicondylitis, and to explore the functional mechanism and ideal treatment. Eighty-six patients who had been treated with acupuncture, obturation and needle-knife were divided into routine group and treatment group randomly. In routine group, there were 42 cases (male 13, female 29, means 40.8 years); and in treatment group there were 44 cases (male 16, female 28, means 41.2 years). There's no further treatment for the routine group after the therapy above, while the treatment group was added with back-rotation traction manipulation. Taking Verhaar therapy effect appraisal system of tennis-ball elbow to evaluate elbow function. After 7 days of therapy, the results were excellent in 13 cases, good in 16, fair in 4, poor in 9 in the routine group; and excellent in 38, good in 4 and fair in 2 in treatment group; and the effect in the treatment group were better than that of the routine group (P Making manipulation after routine acupuncture, local obturation and needle-knife has active meaning to remove trauma inflammation, prevent re-conglutination, promote recovery and prevent recurrence.

  9. Mechanics and complications of reverse shoulder arthroplasty: morse taper failure analysis and prospective rectification

    International Nuclear Information System (INIS)

    Hoskin, HLD; Furie, E; Ganey, TM; Schlatterer, DR; Collins, W

    2017-01-01

    Since Sir John Charnley began his monumental hip arthroplasty work in 1958, clinical researchers have been incrementally improving longevity and functionality of total joint systems, although implant failure occurs on occasion. The purpose of this study is to report the fracture of the humeral tray Morse taper of a reverse total shoulder system (RTSS), which to date has not been reported with metallurgic analysis for any RTSS. There was no reported antecedent fall, motor vehicle collision, or other traumatic event prior to implant fracture in this case. Analysis was performed on the retrieved failed implant by Scanning Electron Microscopy (SEM) and Electron Dispersion Spectroscopy (EDS) in an attempt to determine the failure method, as well as to offer improvements for future implants. At the time of revision surgery all explants were retained from the left shoulder of a 61-year old male who underwent a non-complicated RTSS 4 years prior. The explants, particularly the cracked humeral tray, were processed as required for SEM and EDS. Analysis was performed on the failure sites in order to determine the chemical composition of the different parts of the implant, discover the chemical composition of the filler metal used during the electron beam welding process, and to detect any foreign elements that could suggest corrosion or other evidence of failure etiology. Gross visual inspection of all explants revealed that implant failure was a result of dissociation of the taper from the humeral tray at the weld, leaving the Morse taper embedded in the humeral stem while the tray floated freely in the patient’s shoulder. SEM further confirmed the jagged edges noted grossly at the weld fracture site, both suggesting failure due to torsional forces. EDS detected elevated levels of carbon and oxygen at the fracture site on the taper only and not on the humeral tray. In order to determine the origin of the high levels of C and O, it was considered that in titanium alloys, C

  10. Ultrasonography of the equine shoulder

    International Nuclear Information System (INIS)

    Dik, K.J.

    1996-01-01

    Six horses with shoulder injuries were presented in this report with emphasis on the use of ultrasonography vs. radiography in diagnosis. The two imaging modalities represented valuable and complementary diagnostic procedures. Two horses had fracture fragments of the lateral humeral tuberosity, the accurate ultrasonographic findings encouraging clearer radiographic identification by oblique projections. In one horseultrasonography enabled more accurate localization of calcification within the supraspinatus muscle. In the remaining three cases ultrasonography visualized distension of the bicipital bursa due to aseptic bursitis, bursal hemorrhage, or associated with injury of the biceps brachii muscle and the underlying intermediate humeral tubercle, the bony involvement more clearly demonstrated radiographically

  11. Intra-articular osteotomy for distal humerus malunion

    NARCIS (Netherlands)

    Marti, René K.; Doornberg, Job

    2009-01-01

    Intra-articular osteotomy is considered in the rare case of malunion after a fracture of the distal humerus to restore humeral alignment and gain a functional arc of elbow motion. Traumatic and iatrogenic disruption of the limited blood flow to the distal end of the humerus resulting in avascular

  12. Model of T-Type Fracture in Coal Fracturing and Analysis of Influence Factors of Fracture Morphology

    Directory of Open Access Journals (Sweden)

    Yuwei Li

    2018-05-01

    Full Text Available Special T-type fractures can be formed when coal is hydraulically fractured and there is currently no relevant theoretical model to calculate and describe them. This paper first establishes the height calculation model of vertical fractures in multi-layered formations and deduces the stress intensity factor (SIF at the upper and lower sides of the fracture in the process of vertical fracture extension. Combined with the fracture tip stress analysis method of fracture mechanics theory, the horizontal bedding is taken into account for tensile and shear failure, and the critical mechanical conditions for the formation of horizontal fracture in coal are obtained. Finally, the model of T-type fracture in coal fracturing is established, and it is verified by fracturing simulation experiments. The model calculation result shows that the increase of vertical fracture height facilitates the increase of horizontal fracture length. The fracture toughness of coal has a significant influence on the length of horizontal fracture and there is a threshold. When the fracture toughness is less than the threshold, the length of horizontal fracture remains unchanged, otherwise, the length of horizontal fracture increases rapidly with the increase of fracture toughness. When the shear strength of the interface between the coalbed and the interlayer increases, the length of the horizontal fracture of the T-type fracture rapidly decreases.

  13. Least possible fixation techniques of 4-part valgus impacted fractures of the proximal humerus: a systematic review

    Directory of Open Access Journals (Sweden)

    Andreas Panagopoulos

    2016-03-01

    Full Text Available The valgus-impacted (VI 4-part fractures are a subset of fractures of the proximal humerus with a unique anatomic configuration characterized by a relatively lower incidence of avascular necrosis after operative intervention. We systematically reviewed clinical studies assessing the benefits and harms of least possible fixation techniques (LPFT for this unique fracture type. Such information would be potentially helpful in developing an evidence-based approach in the management of these complex injuries. We performed analytic searches of PubMed, Embase, Web of Science, Google Scholar and the Cochrane Library, restricting it to the years 1991-2014. Included studies had to describe outcomes and complications after primary osteosynthesis with any type of LPFT apart from plate-screws and intramedullary nailing. Eligibility criteria were also included English language, more than 5 cases, minimum follow up of one year and report of clinical outcome using at least one relevant score (Constant, Neer or ASES. Based on 292 database hits we identified 12 eligible studies including 190 four-part valgus impacted fractures in 188 patients. All eligible studies were case series composed of min 8 to max 45 patients per study. The gender distribution was 60% (112 female and 40% (76 male. The average age of the patients at the time of injury was 54.5 years. In 8/12 studies an open reduction was used for fracture fixation using different surgical techniques including KW, cerclage wires, cannulated screws and osteosutures. Closed reduction and percutaneous fixation was used in 4 studies. Mean follow-up time ranged from 24 to 69 months. A good functional outcome (constant score >80 was reported in 9/12 studies. The most common complication was avascular necrosis of the humeral head with an overall incidence of 11% (range, 0-26.3%. Total avascular necrosis (AVN was found in 15/188 patients (7.9% and was more common in percutaneous techniques and partial AVN in 6

  14. Bimalleolar ankle fracture with proximal fibular fracture

    NARCIS (Netherlands)

    Colenbrander, R. J.; Struijs, P. A. A.; Ultee, J. M.

    2005-01-01

    A 56-year-old female patient suffered a bimalleolar ankle fracture with an additional proximal fibular fracture. This is an unusual fracture type, seldom reported in literature. It was operatively treated by open reduction and internal fixation of the lateral malleolar fracture. The proximal fibular

  15. Correlation of Hip Fracture with Other Fracture Types: Toward a Rational Composite Hip Fracture Endpoint

    Science.gov (United States)

    Colón-Emeric, Cathleen; Pieper, Carl F.; Grubber, Janet; Van Scoyoc, Lynn; Schnell, Merritt L; Van Houtven, Courtney Harold; Pearson, Megan; Lafleur, Joanne; Lyles, Kenneth W.; Adler, Robert A.

    2016-01-01

    Purpose With ethical requirements to the enrollment of lower risk subjects, osteoporosis trials are underpowered to detect reduction in hip fractures. Different skeletal sites have different levels of fracture risk and response to treatment. We sought to identify fracture sites which cluster with hip fracture at higher than expected frequency; if these sites respond to treatment similarly, then a composite fracture endpoint could provide a better estimate of hip fracture reduction. Methods Cohort study using Veterans Affairs and Medicare administrative data. Male Veterans (n=5,036,536) aged 50-99 years receiving VA primary care between1999-2009 were included. Fractures were ascertained using ICD9 and CPT codes and classified by skeletal site. Pearson correlation coefficients, logistic regression and kappa statistics, were used to describe the correlation between each fracture type and hip fracture within individuals, without regards to the timing of the events. Results 595,579 (11.8%) men suffered 1 or more fractures and 179,597 (3.6%) suffered 2 or more fractures during the time under study. Of those with one or more fractures, rib was the most common site (29%), followed by spine (22%), hip (21%) and femur (20%). The fracture types most highly correlated with hip fracture were pelvic/acetabular (Pearson correlation coefficient 0.25, p<0.0001), femur (0.15, p<0.0001), and shoulder (0.11, p<0.0001). Conclusions Pelvic, acetabular, femur, and shoulder fractures cluster with hip fractures within individuals at greater than expected frequency. If we observe similar treatment risk reductions within that cluster, subsequent trials could consider use of a composite endpoint to better estimate hip fracture risk. PMID:26151123

  16. Análise da variação dos valores da rotação medial conforme a posição da diáfise do úmero Analysis on the variation of medial rotation values according to the position of the humeral diaphysis

    Directory of Open Access Journals (Sweden)

    Alberto Naoki Miyazaki

    2012-01-01

    shoulder MR limitation. The vertebral level was evaluated by means of a visual scale and was correlated with the angle obtained according to the position of the humeral diaphysis, using the bi-goniometer developed with the Department of Mechanical Engineering of Mackenzie University. RESULTS: The maximum vertebral level reached through MR on the unaffected side ranged from T3 to T12, and on the affected side, from T6 to the trochanter. Repositioning of the affected limb in MR according to the angular values on the normal side showed that 57.13% of the patients reached lower levels, between the sacrum, gluteus and trochanter. From analysis on the maximum vertebral level attained and the variation between the affected angle x (frontal plane: abduction and MR of the shoulder and the unaffected angle x in MR, we observed that the greater the angle of the diaphyseal axis was, the lower the variation in the vertebral level attained was. From evaluating the linear correlation between the variables of difference in maximum vertebral level reached and variation in the affected angle y (extension and abduction of the shoulder and the unaffected angle y in MR, we observed that there was no well-established linear relationship between these variables. CONCLUSION: Measurement of MR using vertebral levels does not correspond to the real values, since it varies according to the positioning of the humeral diaphysis.

  17. Nonoperative Management and Novel Imaging for Posterior Circumflex Humeral Artery Injury in Volleyball.

    Science.gov (United States)

    van de Pol, Daan; Planken, R Nils; Terpstra, Aart; Pannekoek-Hekman, Marja; Kuijer, P Paul F M; Maas, Mario

    We report on a 34-yr-old male elite volleyball player with symptomatic emboli in the spiking hand from a partially thrombosed aneurysm of the posterior circumflex humeral artery (PCHA) in his dominant shoulder. At initial diagnosis and follow-up, a combination of time-resolved and high-resolution steady state contrast-enhanced magnetic resonance angiography (CE-MRA) enabled detailed visualization of: (1) emboli that were not detectable by vascular ultrasound; and (2) the PCHA aneurysm, including compression during abduction and external rotation (ABER provocation). At 15-month follow-up, including forced cessation of volleyball activities over the preceding 9 months, the PCHA aneurysm remained unchanged. Central filling defects in the palmar arch and digital arteries resolved over time and affected arterial vessel segments showed postthrombotic changes. Digital blood pressure values improved substantially and almost normalized during follow-up. In conclusion, this case report is the first to show promising results of nonoperative management for a vascular shoulder overuse injury in a professional volleyball player as an alternative to invasive therapeutic options.

  18. Foal Fractures: Osteochondral Fragmentation, Proximal Sesamoid Bone Fractures/Sesamoiditis, and Distal Phalanx Fractures.

    Science.gov (United States)

    Reesink, Heidi L

    2017-08-01

    Foals are susceptible to many of the same types of fractures as adult horses, often secondary to external sources of trauma. In addition, some types of fractures are specific to foals and occur routinely in horses under 1 year of age. These foal-specific fractures may be due to the unique musculoskeletal properties of the developing animal and may present with distinct clinical signs. Treatment plans and prognoses are tailored specifically to young animals. Common fractures not affecting the long bones in foals are discussed in this article, including osteochondral fragmentation, proximal sesamoid bone fractures/sesamoiditis, and distal phalanx fractures. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Case report

    African Journals Online (AJOL)

    abp

    2015-11-18

    Nov 18, 2015 ... A 57 years old man, left-handed, admitted to department of orthopedics at Chambéry Hospital, France, for distal biceps rupture of the left arm after lifting a heavy object. We observed deformed and amyotrophic right upper limb due to radial nerve palsy complicating humeral communitive fracture (Figure 1).

  20. Acetabular Fracture

    Directory of Open Access Journals (Sweden)

    Chad Correa

    2017-09-01

    Full Text Available History of present illness: A 77-year-old female presented to her primary care physician (PCP with right hip pain after a mechanical fall. She did not lose consciousness or have any other traumatic injuries. She was unable to ambulate post-fall, so X-rays were ordered by her PCP. Her X-rays were concerning for a right acetabular fracture (see purple arrows, so the patient was referred to the emergency department where a computed tomography (CT scan was ordered. Significant findings: The non-contrast CT images show a minimally displaced comminuted fracture of the right acetabulum involving the acetabular roof, medial and anterior walls (red arrows, with associated obturator muscle hematoma (blue oval. Discussion: Acetabular fractures are quite rare. There are 37 pelvic fractures per 100,000 people in the United States annually, and only 10% of these involve the acetabulum. They occur more frequently in the elderly totaling an estimated 4,000 per year. High-energy trauma is the primary cause of acetabular fractures in younger individuals and these fractures are commonly associated with other fractures and pelvic ring disruptions. Fractures secondary to moderate or minimal trauma are increasingly of concern in patients of advanced age.1 Classification of acetabular fractures can be challenging. However, the approach can be simplified by remembering the three basic types of acetabular fractures (column, transverse, and wall and their corresponding radiologic views. First, column fractures should be evaluated with coronally oriented CT images. This type of fracture demonstrates a coronal fracture line running caudad to craniad, essentially breaking the acetabulum into two halves: a front half and a back half. Secondly, transverse fractures should be evaluated by sagittally oriented CT images. By definition, a transverse fracture separates the acetabulum into superior and inferior halves with the fracture line extending from anterior to posterior

  1. Ultrasound assessment of the posterior circumflex humeral artery in elite volleyball players: Aneurysm prevalence, anatomy, branching pattern and vessel characteristics.

    Science.gov (United States)

    van de Pol, Daan; Maas, Mario; Terpstra, Aart; Pannekoek-Hekman, Marja; Alaeikhanehshir, Sena; Kuijer, P Paul F M; Planken, R Nils

    2017-03-01

    To determine the prevalence of posterior circumflex humeral artery (PCHA) aneurysms and vessel characteristics of the PCHA and deep brachial artery (DBA) in elite volleyball players. Two-hundred and eighty players underwent standardized ultrasound assessment of the dominant arm by a vascular technologist. Assessment included determination of PCHA aneurysms (defined as segmental vessel dilatation ≥150 %), PCHA and DBA anatomy, branching pattern, vessel course and diameter. The PCHA and DBA were identified in 100 % and 93 % (260/280) of cases, respectively. The prevalence of PCHA aneurysms was 4.6 % (13/280). All aneurysms were detected in proximal PCHA originating from the axillary artery (AA). The PCHA originated from the AA in 81 % of cases (228/280), and showed a curved course dorsally towards the humeral head in 93 % (211/228). The DBA originated from the AA in 73 % of cases (190/260), and showed a straight course parallel to the AA in 93 % (177/190). PCHA aneurysm prevalence in elite volleyball players is high and associated with a specific branching type: a PCHA that originates from the axillary artery. Radiologists should have a high index of suspicion for this vascular overuse injury. For the first time vessel characteristics and reference values are described to facilitate ultrasound assessment. • Prevalence of PCHA aneurysms is 4.6 % among elite volleyball players. • All aneurysms are in proximal PCHA that originates directly from AA. • Vessel characteristics and reference values are described to facilitate US assessment. • Mean PCHA and DBA diameters can be used as reference values. • Radiologists need a high index of suspicion for this vascular overuse injury.

  2. Associations of early premenopausal fractures with subsequent fractures vary by sites and mechanisms of fractures.

    Science.gov (United States)

    Honkanen, R; Tuppurainen, M; Kroger, H; Alhava, E; Puntila, E

    1997-04-01

    In a retrospective population-based study we assessed whether and how self-reported former fractures sustained at the ages of 20-34 are associated with subsequent fractures sustained at the ages of 35-57. The 12,162 women who responded to fracture questions of the baseline postal enquiry (in 1989) of the Kuopio Osteoporosis Study, Finland formed the study population. They reported 589 former and 2092 subsequent fractures. The hazard ratio (HR), with 95% confidence interval (CI), of a subsequent fracture was 1.9 (1.6-2.3) in women with the history of a former fracture compared with women without such a history. A former low-energy wrist fracture was related to subsequent low-energy wrist [HR = 3.7 (2.0-6.8)] and high-energy nonwrist [HR = 2.4 (1.3-4.4)] fractures, whereas former high-energy nonwrist fractures were related only to subsequent high-energy nonwrist [HR = 2.8 (1.9-4.1)] but not to low-energy wrist [HR = 0.7 (0.3-1.8)] fractures. The analysis of bone mineral density (BMD) data of a subsample of premenopausal women who underwent dual x-ray absorptiometry (DXA) during 1989-91 revealed that those with a wrist fracture due to a fall on the same level at the age of 20-34 recorded 6.5% lower spinal (P = 0.140) and 10.5% lower femoral (P = 0.026) BMD than nonfractured women, whereas the corresponding differences for women with a former nonwrist fracture due to high-energy trauma were -1.8% (P = 0.721) and -2.4% (P = 0. 616), respectively. Our results suggest that an early premenopausal, low-energy wrist fracture is an indicator of low peak BMD which predisposes to subsequent fractures in general, whereas early high-energy fractures are mainly indicators of other and more specific extraskeletal factors which mainly predispose to same types of subsequent fractures only.

  3. Anterior transposition of the radial nerve--a cadaveric study.

    Science.gov (United States)

    Yakkanti, Madhusudhan R; Roberts, Craig S; Murphy, Joshua; Acland, Robert D

    2008-01-01

    The radial nerve is at risk during the posterior plating of the humerus. The purpose of this anatomic study was to assess the extent of radial nerve dissection required for anterior transposition through the fracture site (transfracture anterior transposition). A cadaver study was conducted approaching the humerus by a posterior midline incision. The extent of dissection of the nerve necessary for plate fixation of the humerus fracture was measured. An osteotomy was created to model a humeral shaft fracture at the spiral groove (OTA classification 12-A2, 12-A3). The radial nerve was then transposed anterior to the humeral shaft through the fracture site. The additional dissection of the radial nerve and the extent of release of soft tissue from the humerus shaft to achieve the transposition were measured. Plating required a dissection of the radial nerve 1.78 cm proximal and 2.13 cm distal to the spiral groove. Transfracture anterior transposition of the radial nerve required an average dissection of 2.24 cm proximal and 2.68 cm distal to the spiral groove. The lateral intermuscular septum had to be released for 2.21 cm on the distal fragment to maintain laxity of the transposed nerve. Transfracture anterior transposition of the radial nerve before plating is feasible with dissection proximal and distal to the spiral groove and elevation of the lateral intermuscular septum. Potential clinical advantages of this technique include enhanced fracture site visualization, application of broader plates, and protection of the radial nerve during the internal fixation.

  4. Cyclooxygenase-2 inhibitors and knee prosthesis surgery

    OpenAIRE

    Meunier, Andreas

    2008-01-01

    Adverse effects of cyclooxygenase (COX) inhibitors on bone healing have previously been demonstrated in diaphyseal fracture models in animals. In spite of that, they are widely used as postoperative analgesics in orthopaedic surgery. After joint replacement, a bone repair process starts at the interface between bone and cement. If this process is disturbed, the prosthesis may never become rigidly fixed to the bone, leading to migration and with time loosening. This thesis investigates the eff...

  5. Hydraulic fracture propagation modeling and data-based fracture identification

    Science.gov (United States)

    Zhou, Jing

    Successful shale gas and tight oil production is enabled by the engineering innovation of horizontal drilling and hydraulic fracturing. Hydraulically induced fractures will most likely deviate from the bi-wing planar pattern and generate complex fracture networks due to mechanical interactions and reservoir heterogeneity, both of which render the conventional fracture simulators insufficient to characterize the fractured reservoir. Moreover, in reservoirs with ultra-low permeability, the natural fractures are widely distributed, which will result in hydraulic fractures branching and merging at the interface and consequently lead to the creation of more complex fracture networks. Thus, developing a reliable hydraulic fracturing simulator, including both mechanical interaction and fluid flow, is critical in maximizing hydrocarbon recovery and optimizing fracture/well design and completion strategy in multistage horizontal wells. A novel fully coupled reservoir flow and geomechanics model based on the dual-lattice system is developed to simulate multiple nonplanar fractures' propagation in both homogeneous and heterogeneous reservoirs with or without pre-existing natural fractures. Initiation, growth, and coalescence of the microcracks will lead to the generation of macroscopic fractures, which is explicitly mimicked by failure and removal of bonds between particles from the discrete element network. This physics-based modeling approach leads to realistic fracture patterns without using the empirical rock failure and fracture propagation criteria required in conventional continuum methods. Based on this model, a sensitivity study is performed to investigate the effects of perforation spacing, in-situ stress anisotropy, rock properties (Young's modulus, Poisson's ratio, and compressive strength), fluid properties, and natural fracture properties on hydraulic fracture propagation. In addition, since reservoirs are buried thousands of feet below the surface, the

  6. Avaliação radiográfica e de função de vôo após fixação de osteotomias distais do úmero em pombas (Columba livia, com modelo de fixador externo articulado Radiologic and flight function evaluation after fixation of distal humeral osteotomies in pigeons, with model of articulated external fixator

    Directory of Open Access Journals (Sweden)

    Vanessa C.M. Ferraz

    2008-08-01

    viabilidade de músculos e tendões, e assim, garantindo a capacidade de vôo das aves tratadas, sendo um método adequado para a reparação de fraturas distais de úmero em aves quando se pretende a reabilitação destes animais.The treatment of distal humeral fractures in birds is very difficult, technically and for consolidation and maintenance of normal function of the wing, because theses bones are pneumatic, and its cortices very thin. The ankylosis of the humerus-radius-ulnar joint with external fixator is unviable for birds intended for rehabilitation and release. In all animals, the experimental fixator was placed over the humerus, with its articulation over the humerus-radial-ulnar joint e the extension of the fixator was placed over the ulna. The animals were divided in two groups: bilateral surgeries with ankylosis in one wing (static wing and maintenance of the joint function in the other (dynamic wing (Group 1, and unilateral surgery, with maintenance of the joint function (dynamic wing (Group 2. The bonny callus was evaluated with radiographs: post-surgical, at 3, 6 and 9 weeks. The birds in Group 2 were evaluated as of their flight abilities between 11 and 15 weeks after surgery. The wing amplitude and humeral length was evaluated in all animals, after euthanasia. At 6 weeks, all the animals in Group 2, that underwent unilateral surgery, without ankylosis, and four animals in Group 1, that underwent bilateral surgeries: ankylosis of one elbow (static wing and not of the other (dynamic wing, presented radiographic and clinical consolidation of the fractures. Two animals in Group 1 only presented consolidation of the dynamic wing at 9 weeks and of the static wing at 12 weeks. All the animals in Group 2 presented adequate flight capacity, in at least 13 weeks after surgery. There are few published papers on bird osteosynthesis, and therefore we studied the use of articulated external fixator for the stabilization of distal humeral fractures, avoiding ankylosis

  7. Distinguishing stress fractures from pathologic fractures: a multimodality approach

    International Nuclear Information System (INIS)

    Fayad, Laura M.; Kamel, Ihab R.; Kawamoto, Satomi; Bluemke, David A.; Fishman, Elliot K.; Frassica, Frank J.

    2005-01-01

    Whereas stress fractures occur in normal or metabolically weakened bones, pathologic fractures occur at the site of a bone tumor. Unfortunately, stress fractures may share imaging features with pathologic fractures on plain radiography, and therefore other modalities are commonly utilized to distinguish these entities. Additional cross-sectional imaging with CT or MRI as well as scintigraphy and PET scanning is often performed for further evaluation. For the detailed assessment of a fracture site, CT offers a high-resolution view of the bone cortex and periosteum which aids the diagnosis of a pathologic fracture. The character of underlying bone marrow patterns of destruction can also be ascertained along with evidence of a soft tissue mass. MRI, however, is a more sensitive technique for the detection of underlying bone marrow lesions at a fracture site. In addition, the surrounding soft tissues, including possible involvement of adjacent muscle, can be well evaluated with MRI. While bone scintigraphy and FDG-PET are not specific, they offer a whole-body screen for metastases in the case of a suspected malignant pathologic fracture. In this review, we present select examples of fractures that underscore imaging features that help distinguish stress fractures from pathologic fractures, since accurate differentiation of these entities is paramount. (orig.)

  8. A Multicentric, Open-Label, Randomized, Comparative Clinical Trial of Two Different Doses of Expanded hBM-MSCs Plus Biomaterial versus Iliac Crest Autograft, for Bone Healing in Nonunions after Long Bone Fractures: Study Protocol

    Directory of Open Access Journals (Sweden)

    Enrique Gómez-Barrena

    2018-01-01

    Full Text Available ORTHOUNION is a multicentre, open, comparative, three-arm, randomized clinical trial (EudraCT number 2015-000431-32 to compare the efficacy, at one and two years, of autologous human bone marrow-derived expanded mesenchymal stromal cell (hBM-MSC treatments versus iliac crest autograft (ICA to enhance bone healing in patients with diaphyseal and/or metaphysodiaphyseal fracture (femur, tibia, and humerus status of atrophic or oligotrophic nonunion (more than 9 months after the acute fracture, including recalcitrant cases after failed treatments. The primary objective is to determine if the treatment with hBM-MSCs combined with biomaterial is superior to ICA in obtaining bone healing. If confirmed, a secondary objective is set to determine if the dose of 100 × 106 hBM-MSCs is noninferior to that of 200 × 106 hBM-MSCs. The participants (n=108 will be randomly assigned to either the experimental low dose (n=36, the experimental high dose (n=36, or the comparator arm (n=36 using a central randomization service. The trial will be conducted in 20 clinical centres in Spain, France, Germany, and Italy under the same clinical protocol. The confirmation of superiority for the proposed ATMP in nonunions may foster the future of bone regenerative medicine in this indication. On the contrary, absence of superiority may underline its limitations in clinical use.

  9. A Multicentric, Open-Label, Randomized, Comparative Clinical Trial of Two Different Doses of Expanded hBM-MSCs Plus Biomaterial versus Iliac Crest Autograft, for Bone Healing in Nonunions after Long Bone Fractures: Study Protocol.

    Science.gov (United States)

    Gómez-Barrena, Enrique; Padilla-Eguiluz, Norma G; Avendaño-Solá, Cristina; Payares-Herrera, Concepción; Velasco-Iglesias, Ana; Torres, Ferran; Rosset, Philippe; Gebhard, Florian; Baldini, Nicola; Rubio-Suarez, Juan C; García-Rey, Eduardo; Cordero-Ampuero, José; Vaquero-Martin, Javier; Chana, Francisco; Marco, Fernando; García-Coiradas, Javier; Caba-Dessoux, Pedro; de la Cuadra, Pablo; Hernigou, Philippe; Flouzat-Lachaniette, Charles-Henri; Gouin, François; Mainard, Didier; Laffosse, Jean Michel; Kalbitz, Miriam; Marzi, Ingo; Südkamp, Norbert; Stöckle, Ulrich; Ciapetti, Gabriela; Donati, Davide Maria; Zagra, Luigi; Pazzaglia, Ugo; Zarattini, Guido; Capanna, Rodolfo; Catani, Fabio

    2018-01-01

    ORTHOUNION is a multicentre, open, comparative, three-arm, randomized clinical trial (EudraCT number 2015-000431-32) to compare the efficacy, at one and two years, of autologous human bone marrow-derived expanded mesenchymal stromal cell (hBM-MSC) treatments versus iliac crest autograft (ICA) to enhance bone healing in patients with diaphyseal and/or metaphysodiaphyseal fracture (femur, tibia, and humerus) status of atrophic or oligotrophic nonunion (more than 9 months after the acute fracture, including recalcitrant cases after failed treatments). The primary objective is to determine if the treatment with hBM-MSCs combined with biomaterial is superior to ICA in obtaining bone healing. If confirmed, a secondary objective is set to determine if the dose of 100 × 10 6 hBM-MSCs is noninferior to that of 200 × 10 6 hBM-MSCs. The participants ( n = 108) will be randomly assigned to either the experimental low dose ( n = 36), the experimental high dose ( n = 36), or the comparator arm ( n = 36) using a central randomization service. The trial will be conducted in 20 clinical centres in Spain, France, Germany, and Italy under the same clinical protocol. The confirmation of superiority for the proposed ATMP in nonunions may foster the future of bone regenerative medicine in this indication. On the contrary, absence of superiority may underline its limitations in clinical use.

  10. Double segmental tibial fractures - an unusual fracture pattern

    Directory of Open Access Journals (Sweden)

    Bali Kamal

    2012-02-01

    Full Text Available 【Abstract】A case of a 50-year-old pedestrian who was hit by a bike and suffered fractures of both bones of his right leg was presented. Complete clinical and radiographic assessment showed double segmental fractures of the tibia and multisegmental fractures of the fibula. Review of the literature revealed that this fracture pattern was unique and only a single case was reported so far. Moreover, we discussed the possible mechanisms which can lead to such an injury. We also discussed the management of segmental tibial fracture and the difficulties encountered with them. This case was managed by modern osteosynthesis tech- nique with a pleasing outcome. Key words: Fracture, bone; Tibia; Fibula; Nails

  11. Ankle fracture spur sign is pathognomonic for a variant ankle fracture.

    Science.gov (United States)

    Hinds, Richard M; Garner, Matthew R; Lazaro, Lionel E; Warner, Stephen J; Loftus, Michael L; Birnbaum, Jacqueline F; Burket, Jayme C; Lorich, Dean G

    2015-02-01

    The hyperplantarflexion variant ankle fracture is composed of a posterior tibial lip fracture with posterolateral and posteromedial fracture fragments separated by a vertical fracture line. This infrequently reported injury pattern often includes an associated "spur sign" or double cortical density at the inferomedial tibial metaphysis. The objective of this study was to quantitatively establish the association of the ankle fracture spur sign with the hyperplantarflexion variant ankle fracture. Our clinical database of operative ankle fractures was retrospectively reviewed for the incidence of hyperplantarflexion variant and nonvariant ankle fractures as determined by assessment of injury radiographs, preoperative advanced imaging, and intraoperative observation. Injury radiographs were then evaluated for the presence of the spur sign, and association between the spur sign and variant fractures was analyzed. The incidence of the hyperplantarflexion variant fracture among all ankle fractures was 6.7% (43/640). The spur sign was present in 79% (34/43) of variant fractures and absent in all nonvariant fractures, conferring a specificity of 100% in identifying variant fractures. Positive predictive value and negative predictive value were 100% and 99%, respectively. The ankle fracture spur sign was pathognomonic for the hyperplantarflexion variant ankle fracture. It is important to identify variant fractures preoperatively as patient positioning, operative approach, and fixation construct of variant fractures often differ from those employed for osteosynthesis of nonvariant fractures. Identification of the spur sign should prompt acquisition of advanced imaging to formulate an appropriate operative plan to address the variant fracture pattern. Level III, retrospective comparative study. © The Author(s) 2014.

  12. Association of Ipsilateral Rib Fractures With Displacement of Midshaft Clavicle Fractures.

    Science.gov (United States)

    Stahl, Daniel; Ellington, Matthew; Brennan, Kindyle; Brennan, Michael

    2017-04-01

    To determine whether the presence of ipsilateral rib fractures affects the rate of a clavicle fracture being unstable (>100% displacement). A retrospective review from 2002-2013 performed at a single level 1 trauma center evaluated 243 midshaft clavicle fractures. Single Level 1 trauma center. These fractures were subdivided into those with ipsilateral rib fractures (CIR; n = 149) and those without ipsilateral rib fractures (CnIR; n = 94). The amount of displacement was measured on the initial injury radiograph and subsequent follow-up radiographs. Fractures were classified into either 100% displacement, based on anteroposterior radiographs. Ipsilateral rib fractures were recorded based on which number rib was fractured and the total number of fractured ribs. One hundred sixteen (78%) of the CIR group and 51 (54%) of the CnIR group were found to have >100% displacement at follow-up (P = 0.0047). Seventy-two percent of the CIR group demonstrated progression from 100% displacement of the fracture compared with only 54% of the CnIR group (P fracture to >100% was 4.08 (P = 0.000194) when ribs 1-4 were fractured and not significant for rib fractures 5-8 or 9-12. The presence of concomitant ipsilateral rib fractures significantly increases the rate of midshaft clavicle fractures being >100% displaced. In addition, a fracture involving the upper one-third of the ribs significantly increases the rate of the clavicle fracture being >100% displaced on early follow-up. Clavicle fractures with associated ipsilateral rib fractures tend to demonstrate an increased amount of displacement on follow-up radiographs compared with those without ipsilateral rib fractures. Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.

  13. Flow characteristics through a single fracture of artificial fracture system

    International Nuclear Information System (INIS)

    Park, Byoung Yoon; Bae, Dae Seok; Kim, Chun Soo; Kim, Kyung Su; Koh, Young Kwon; Jeon, Seok Won

    2001-04-01

    Fracture flow in rock masses is one of the most important issues in petroleum engineering, geology, and hydrogeology. Especially, in case of the HLW disposal, groundwater flow in fractures is an important factor in the performance assessment of the repository because the radionuclides move along the flowing groundwater through fractures. Recently, the characterization of fractures and the modeling of fluid flow in fractures are studied by a great number of researchers. Among those studies, the hydraulic behavior in a single fracture is one of the basic issues for understanding of fracture flow in rockmass. In this study, a fluid flow test in the single fracture made of transparent epoxy replica was carried out to obtain the practical exponent values proposed from the Cubic law and to estimate the flow rates through a single fracture. Not only the relationship between flow rates and the geometry of fracture was studied, but also the various statistical parameters of fracture geometry were compared to the effective transmissivity data obtained from computer simulation.

  14. A Rare Nasal Bone Fracture: Anterior Nasal Spine Fracture

    Directory of Open Access Journals (Sweden)

    Egemen Kucuk

    2014-04-01

    Full Text Available Anterior nasal spine fractures are a quite rare type of nasal bone fractures. Associated cervical spine injuries are more dangerous than the nasal bone fracture. A case of the anterior nasal spine fracture, in a 18-year-old male was presented. Fracture of the anterior nasal spine, should be considered in the differential diagnosis of the midface injuries and also accompanying cervical spine injury should not be ignored.

  15. Fracture of the styloid process associated with the mandible fracture

    Directory of Open Access Journals (Sweden)

    K N Dubey

    2013-01-01

    Full Text Available Fracture of the styloid process (SP of temporal bone is an uncommon injuries. Fracture of the SP can be associated with the facial injuries including mandible fracture. However, injury to the SP may be concealed and missed diagnosis may lead to the improper or various unnecessary treatments. A rare case of SP fracture associated with the ipsilateral mandibular fracture and also the diagnostic and management considerations of the SP fracture are discussed.

  16. Coupled processes in single fractures, double fractures and fractured porous media

    International Nuclear Information System (INIS)

    Tsang, C.F.

    1986-12-01

    The emplacement of a nuclear waste repository in a fractured porous medium provides a heat source of large dimensions over an extended period of time. It also creates a large cavity in the rock mass, changing significantly the stress field. Such major changes induce various coupled thermohydraulic, hydromechanic and hydrochemical transport processes in the environment around a nuclear waste repository. The present paper gives, first, a general overview of the coupled processes involving thermal, mechanical, hydrological and chemical effects. Then investigations of a number of specific coupled processes are described in the context of fluid flow and transport in a single fracture, two intersecting fractures and a fractured porous medium near a nuclear waste repository. The results are presented and discussed

  17. Facial Fractures.

    Science.gov (United States)

    Ghosh, Rajarshi; Gopalkrishnan, Kulandaswamy

    2018-06-01

    The aim of this study is to retrospectively analyze the incidence of facial fractures along with age, gender predilection, etiology, commonest site, associated dental injuries, and any complications of patients operated in Craniofacial Unit of SDM College of Dental Sciences and Hospital. This retrospective study was conducted at the Department of OMFS, SDM College of Dental Sciences, Dharwad from January 2003 to December 2013. Data were recorded for the cause of injury, age and gender distribution, frequency and type of injury, localization and frequency of soft tissue injuries, dentoalveolar trauma, facial bone fractures, complications, concomitant injuries, and different treatment protocols.All the data were analyzed using statistical analysis that is chi-squared test. A total of 1146 patients reported at our unit with facial fractures during these 10 years. Males accounted for a higher frequency of facial fractures (88.8%). Mandible was the commonest bone to be fractured among all the facial bones (71.2%). Maxillary central incisors were the most common teeth to be injured (33.8%) and avulsion was the most common type of injury (44.6%). Commonest postoperative complication was plate infection (11%) leading to plate removal. Other injuries associated with facial fractures were rib fractures, head injuries, upper and lower limb fractures, etc., among these rib fractures were seen most frequently (21.6%). This study was performed to compare the different etiologic factors leading to diverse facial fracture patterns. By statistical analysis of this record the authors come to know about the relationship of facial fractures with gender, age, associated comorbidities, etc.

  18. Chance Fracture Secondary to a Healed Kyphotic Compression Osteoporotic Fracture

    Directory of Open Access Journals (Sweden)

    Teh KK

    2009-11-01

    Full Text Available Chance fracture is an unstable vertebral fracture, which usually results from a high velocity injury. An elderly lady with a previously healed osteoporotic fracture of the T12 and L1 vertebra which resulted in a severe kyphotic deformity subsequently sustained a Chance fracture of the adjacent L2 vertebrae after a minor fall. The previously fracture left her with a deformity which resulted in significant sagittal imbalance therefore predisposing her to this fracture. This case highlights the importance of aggressive treatment of osteoporotic fractures in order to prevent significant sagittal imbalance from resultant (i.e. kyphotic deformity.

  19. Hip Fracture

    Science.gov (United States)

    ... hip fractures in people of all ages. In older adults, a hip fracture is most often a result of a fall from a standing height. In people with very weak bones, a hip fracture can occur simply by standing on the leg and twisting. Risk factors The rate of hip fractures increases substantially with ...

  20. Case report

    African Journals Online (AJOL)

    abp

    5 déc. 2017 ... chez le deuxième malade. Beaucoup de travaux ont décrit le mécanisme des luxations antérieures de l'épaule [3, 4]. Le mécanisme décrit est similaire à celle du tableau de bord dans un accident d'automobile où une fracture de la diaphyse fémorale associée à une luxation de la hanche homolatérale [5].

  1. Ankle fractures have features of an osteoporotic fracture.

    Science.gov (United States)

    Lee, K M; Chung, C Y; Kwon, S S; Won, S H; Lee, S Y; Chung, M K; Park, M S

    2013-11-01

    We report the bone attenuation of ankle joint measured on computed tomography (CT) and the cause of injury in patients with ankle fractures. The results showed age- and gender-dependent low bone attenuation and low-energy trauma in elderly females, which suggest the osteoporotic features of ankle fractures. This study was performed to investigate the osteoporotic features of ankle fracture in terms of bone attenuation and cause of injury. One hundred ninety-four patients (mean age 51.0 years, standard deviation 15.8 years; 98 males and 96 females) with ankle fracture were included. All patients underwent CT examination, and causes of injury (high/low-energy trauma) were recorded. Mean bone attenuations of the talus, medial malleolus, lateral malleolus, and distal tibial metaphysis were measured on CT images. Patients were divided into younger age (fractures than the younger age group. With increasing age, bone attenuations tended to decrease and the difference of bone attenuation between the genders tended to increase in the talus, medial malleolus, lateral malleolus, and distal tibial metaphysis. Ankle fracture had features of osteoporotic fracture that is characterized by age- and gender-dependent low bone attenuation. Ankle fracture should not be excluded from the clinical and research interest as well as from the benefit of osteoporosis management.

  2. A Rare Entity: Bilateral First Rib Fractures Accompanying Bilateral Scapular Fractures

    OpenAIRE

    Gulbahar, Gultekin; Kaplan, Tevfik; Turker, Hasan Bozkurt; Gundogdu, Ahmet Gokhan; Han, Serdar

    2015-01-01

    First rib fractures are scarce due to their well-protected anatomic locations. Bilateral first rib fractures accompanying bilateral scapular fractures are very rare, although they may be together with scapular and clavicular fractures. According to our knowledge, no case of bilateral first rib fractures accompanying bilateral scapular fractures has been reported, so we herein discussed the diagnosis, treatment, and complications of bone fractures due to thoracic trauma in bias of this rare en...

  3. A Rare Entity: Bilateral First Rib Fractures Accompanying Bilateral Scapular Fractures.

    Science.gov (United States)

    Gulbahar, Gultekin; Kaplan, Tevfik; Turker, Hasan Bozkurt; Gundogdu, Ahmet Gokhan; Han, Serdar

    2015-01-01

    First rib fractures are scarce due to their well-protected anatomic locations. Bilateral first rib fractures accompanying bilateral scapular fractures are very rare, although they may be together with scapular and clavicular fractures. According to our knowledge, no case of bilateral first rib fractures accompanying bilateral scapular fractures has been reported, so we herein discussed the diagnosis, treatment, and complications of bone fractures due to thoracic trauma in bias of this rare entity.

  4. Relationships between fractures

    Science.gov (United States)

    Peacock, D. C. P.; Sanderson, D. J.; Rotevatn, A.

    2018-01-01

    Fracture systems comprise many fractures that may be grouped into sets based on their orientation, type and relative age. The fractures are often arranged in a network that involves fracture branches that interact with one another. Interacting fractures are termed geometrically coupled when they share an intersection line and/or kinematically coupled when the displacements, stresses and strains of one fracture influences those of the other. Fracture interactions are characterised in terms of the following. 1) Fracture type: for example, whether they have opening (e.g., joints, veins, dykes), closing (stylolites, compaction bands), shearing (e.g., faults, deformation bands) or mixed-mode displacements. 2) Geometry (e.g., relative orientations) and topology (the arrangement of the fractures, including their connectivity). 3) Chronology: the relative ages of the fractures. 4) Kinematics: the displacement distributions of the interacting fractures. It is also suggested that interaction can be characterised in terms of mechanics, e.g., the effects of the interaction on the stress field. It is insufficient to describe only the components of a fracture network, with fuller understanding coming from determining the interactions between the different components of the network.

  5. A Rare Entity: Bilateral First Rib Fractures Accompanying Bilateral Scapular Fractures

    Directory of Open Access Journals (Sweden)

    Gultekin Gulbahar

    2015-01-01

    Full Text Available First rib fractures are scarce due to their well-protected anatomic locations. Bilateral first rib fractures accompanying bilateral scapular fractures are very rare, although they may be together with scapular and clavicular fractures. According to our knowledge, no case of bilateral first rib fractures accompanying bilateral scapular fractures has been reported, so we herein discussed the diagnosis, treatment, and complications of bone fractures due to thoracic trauma in bias of this rare entity.

  6. Proximal femoral fractures.

    Science.gov (United States)

    Webb, Lawrence X

    2002-01-01

    Fractures of the proximal femur include fractures of the head, neck, intertrochanteric, and subtrochanteric regions. Head fractures commonly accompany dislocations. Neck fractures and intertrochanteric fractures occur with greatest frequency in elderly patients with a low bone mineral density and are produced by low-energy mechanisms. Subtrochanteric fractures occur in a predominantly strong cortical osseous region which is exposed to large compressive stresses. Implants used to address these fractures must be able to accommodate significant loads while the fractures consolidate. Complications secondary to these injuries produce significant morbidity and include infection, nonunion, malunion, decubitus ulcers, fat emboli, deep venous thrombosis, pulmonary embolus, pneumonia, myocardial infarction, stroke, and death.

  7. Fracture mechanisms and fracture control in composite structures

    Science.gov (United States)

    Kim, Wone-Chul

    Four basic failure modes--delamination, delamination buckling of composite sandwich panels, first-ply failure in cross-ply laminates, and compression failure--are analyzed using linear elastic fracture mechanics (LEFM) and the J-integral method. Structural failures, including those at the micromechanical level, are investigated with the aid of the models developed, and the critical strains for crack propagation for each mode are obtained. In the structural fracture analyses area, the fracture control schemes for delamination in a composite rib stiffener and delamination buckling in composite sandwich panels subjected to in-plane compression are determined. The critical fracture strains were predicted with the aid of LEFM for delamination and the J-integral method for delamination buckling. The use of toughened matrix systems has been recommended for improved damage tolerant design for delamination crack propagation. An experimental study was conducted to determine the onset of delamination buckling in composite sandwich panel containing flaws. The critical fracture loads computed using the proposed theoretical model and a numerical computational scheme closely followed the experimental measurements made on sandwich panel specimens of graphite/epoxy faceskins and aluminum honeycomb core with varying faceskin thicknesses and core sizes. Micromechanical models of fracture in composites are explored to predict transverse cracking of cross-ply laminates and compression fracture of unidirectional composites. A modified shear lag model which takes into account the important role of interlaminar shear zones between the 0 degree and 90 degree piles in cross-ply laminate is proposed and criteria for transverse cracking have been developed. For compressive failure of unidirectional composites, pre-existing defects play an important role. Using anisotropic elasticity, the stress state around a defect under a remotely applied compressive load is obtained. The experimentally

  8. Acromioclavicular dislocation type VI associated with diaphyseal fracture of the clavicle Luxação acromioclavicular tipo VI associada à fratura diafisária da clavícula

    Directory of Open Access Journals (Sweden)

    Evander Azevedo Grossi

    2013-01-01

    Full Text Available The purpose is to present a very unusual case of the acromioclavicular joint inferior dislocation associated with the clavicle fracture. It concerns to a young patient who had a bike fall and had this type of pathology, had been operated and obtained excellent clinic result. The literature mentions many cases of subcoracoide dislocation, but there are only two subacromial similar to ours. The case is described, a literary revision is done and discussed and the treatment is discussed.

  9. ISSN 2073-9990 East Cent. Afr. J. surg

    African Journals Online (AJOL)

    Valued eMachines Customer

    especially between 5 and 7years because fusion of the distal humeral physis peaks at age six.3 There are two major types of supracondylar humerus fractures extension (95% of cases) and flexion (5% of cases)1,2. While different ..... P.J. Walmsley, H.B. Kelly, J.E. Robb, I.H. Annan, D.E. Porter. Delay increases the need for.

  10. Dating fractures and fracture movement in the Lac du Bonnet Batholith

    International Nuclear Information System (INIS)

    Gascoyne, M.; Brown, A.; Ejeckam, R.B.; Everitt, R.A.

    1997-04-01

    This report examines and summarizes all work that has been done from 1980 to the present in determining the age of rock crystallization, fracture initiation, fracture reactivation and rates of fracture movement in the Lac du Bonnet Batholith to provide information for Atomic Energy of Canada Limited's (AECL) Canadian Nuclear Fuel Waste Management Program. Geological and petrographical indicators of relative age (e.g. cross-cutting relationships, sequences of fracture infilling minerals, P-T characteristics of primary and secondary minerals) are calibrated with radiometric age determinations on minerals and whole rock samples, using 87 Rb- 87 Sr, 40 K- 39 Ar, 40 Ar- 39 Ar and fission track methods. Most fractures and fracture zones inclined at low angles are found to be ancient features, first formed in the Early Proterozoic under conditions of deuteric alteration. Following some movement on fractures in the Late Proterozoic and Early Paleozoic, reactivation of fractures during the Pleistocene is established from uranium-series dating methods and use of stable isotopic contents of fracture infilling minerals (mainly calcite). Some indication of movement on fracture zones during the Pleistocene is given by electron spin resonance dating techniques on fault gouge. The slow rate of propagation of fractures is indicated by mineral infillings, their P-T characteristics and U-series calcite ages in a fracture in sparsely fractured rock, accessible from AECL's Underground Research Laboratory. These results collectively indicate that deep fractures observed in the batholith are ancient features and the fracturing and jointing in the upper 200 m is relatively recent (< 1 Ma) and largely a result of stress release. (author)

  11. Evaluation of malrotation following intramedullary nailing in a femoral shaft fracture model: Can a 3D c-arm improve accuracy?

    Science.gov (United States)

    Ramme, Austin J; Egol, Jonathan; Chang, Gregory; Davidovitch, Roy I; Konda, Sanjit

    2017-07-01

    Difficulty determining anatomic rotation following intramedullary (IM) nailing of the femur continues to be problematic for surgeons. Clinical exam and fluoroscopic imaging of the hip and knee have been used to estimate femoral version, but are inaccurate. We hypothesize that 3D c-arm imaging can be used to accurately measure femoral version following IM nailing of femur fractures to prevent rotational malreduction. A midshaft osteotomy was created in a femur Sawbone to simulate a transverse diaphyseal fracture. An intramedullary (IM) nail was inserted into the Sawbone femur without locking screws or cephalomedullary fixation. A goniometer was used to simulate four femoral version situations after IM nailing: 20° retroversion, 0° version, 15° anteversion, and 30° anteversion. In each simulated position, 3D c-arm imaging and, for comparison purposes, perfect lateral radiographs of the knee and hip were performed. The femoral version of each simulated 3D and fluoroscopic case was measured and the results were tabulated. The measured version from the 3D c-arm images was 22.25° retroversion, 0.66° anteversion, 19.53° anteversion, and 25.15° anteversion for the simulated cases of 20° retroversion, 0° version, 15° anteversion, and 30° anteversion, respectively. The lateral fluoroscopic views were measured to be 9.66° retroversion, 12.12° anteversion, 20.91° anteversion, and 18.77° anteversion for the simulated cases, respectively. This study demonstrates the utility of a novel intraoperative method to evaluate femur rotational malreduction following IM nailing. The use of 3D c-arm imaging to measure femoral version offers accuracy and reproducibility. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Desenvolvimento e desempenho de um fixador flexível na consolidação de fraturas diafisárias transversais provocadas iatrogênicamente na tíbia de carneiros Development and performance of a flexible fixator on bone healing of transverse diaphyseal fracture caused iatrogenically in the sheep tibiae

    Directory of Open Access Journals (Sweden)

    Giuliano Barbieri

    2011-06-01

    Full Text Available Foi realizado um estudo experimental sobre o desenvolvimento e desempenho de um fixador externo flexível no processo de consolidação de tíbias de carneiros submetidas à osteotomia transversa mediodiafisária. Foram empregados no estudo 20 carneiros da raça Santa Inês, com massa corporal média de 37kg, divididos em diferentes grupos conforme o período de observação pós-operatória, de 30, 45, 60 e 90 dias. Ao final, os animais sofreram a eutanásia e as tíbias foram removidas para estudo de volumetria transversal do calo ósseo por tomografia computadorizada e ensaio mecânico destrutivo. Os resultados mostraram que ocorreu a formação de calo ósseo volumoso, caracterizando assim a ocorrência de deslocamento de carga axial para o foco da osteotomia, promovida pelo fixador externo utilizado. No ensaio mecânico, observou-se que as comparações entre os grupos respectivos intactos e operados foram significantemente diferentes (PAn experimental study was carried out to verify the development and performance of a flexible external fixator on the bone healing process of the tibia of sheep submitted to a transverse diaphyseal osteotomy. It was used twenty Santa Inês sheep with average weigh of 37kg divided in groups, according to the period of postoperative observation of 30, 45, 60 and 90 days. At the end, the animals were sacrificed and the tibiae were removed for study of transverse callus volumetric by computed tomography and destructive mechanical testing. The results had shown that the formation of voluminous callus occurred, thus characterizing the occurrence of displacement of axial load to the focus of the osteotomy, promoted by the used external fixator used. The mechanical testing showed that the comparisons between the respective intact and operated groups were significantly different (P<0.05 except for the group with 90 days, which demonstrated equivalent stiffness when compared to normal bone. In none of the animals

  13. Physical fracture properties (fracture surfaces as information sources; crackgrowth and fracture mechanisms; exemples of cracks)

    International Nuclear Information System (INIS)

    Meny, Lucienne.

    1979-06-01

    Fracture surfaces are considered as a useful source of informations: an introduction to fractography is presented; the fracture surface may be observed through X ray microanalysis, and other physical methods such as Auger electron spectroscopy or secundary ion emission. The mechanisms of macroscopic and microscopic crackgrowth and fracture are described, in the case of unstable fracture (cleavage, ductile with shear, intergranular brittleness) and of progressive crack propagation (creep, fatigue). Exemples of cracks are presented in the last chapter [fr

  14. Stress Fractures

    Science.gov (United States)

    Stress fractures Overview Stress fractures are tiny cracks in a bone. They're caused by repetitive force, often from overuse — such as repeatedly jumping up and down or running long distances. Stress fractures can also arise from normal use of ...

  15. Transstyloid, transscaphoid, transcapitate fracture: a variant of scaphocapitate fractures.

    LENUS (Irish Health Repository)

    Burke, Neil G

    2014-01-01

    Transstyloid, transscaphoid, transcapitate fractures are uncommon. We report the case of a 28-year-old man who sustained this fracture following direct trauma. The patient was successfully treated by open reduction internal fixation of the scaphoid and proximal capitate fragment, with a good clinical outcome at 1-year follow-up. This pattern is a new variant of scaphocapitate fracture as involves a fracture of the radial styloid as well.

  16. Risk of hip fracture after osteoporosis fractures. 451 women with fracture of lumbar spine, olecranon, knee or ankle

    DEFF Research Database (Denmark)

    Lauritzen, J B; Lund, B

    1993-01-01

    In a follow-up study during 1976-1984, the risk of a subsequent hip fracture was investigated in women aged 60-99 years, hospitalized for the following fractures: lumbar spine (n 70), olecranon (n 52), knee (n 129) and ankle (n 200). Follow-up ranged from 0 to 9 years. Observation time of the 4...... different fractures were 241, 180, 469, and 779, person-years, respectively. In women aged 60-79 years with one of the following fractures the relative risk of a subsequent hip fracture was increased by 4.8 (lumbar spine), 4.1 (olecranon), 3.5 (knee) and 1.5 (ankle). The relative risk of hip fracture showed...... a tendency to level off 3 years after the primary fracture....

  17. Utilization of the bicipital groove axis for confirming alignment of the humerus with transepicondylar and ulnar shaft axes during intramedullary nailing.

    Science.gov (United States)

    Meriç, Gökhan; Zeybek, Gülşah; Kıray, Amaç; Atik, Aziz; Budeyri, Aydın; Koşay, Can

    2015-01-01

    Intramedullary nailing is the preferred surgical treatment of humerus shaft fractures. The purpose of this study was to investigate the relationship between the bicipital groove and specific anatomical landmarks in achieving correct alignment of the humerus during intramedullary nailing, and to describe these anatomical landmarks. Thirty (15 right; 15 left) total upper cadaver extremities were used in this study. After the anatomical landmarks were identified and marked, humeral head axis, transepicondylar axis, ulnar shaft axis, bicipital groove axis, and angular measurements of these were obtained. The mean angle between the bicipital groove axis and transepicondylar axis was 48.17°±12.35º (range: 20.10º to 74.6º). The mean angle between the bicipital groove axis and ulna diaphysis axis was 41.82º±11.56 º (range: 17.91º to 68.27º). The mean angle between the humeral head axis and bicipital groove axis was 20.53°±3.90º (range: 11.85º to 31.81º). The mean retroversion angle between the humeral head axis and transepicondylar axis was 27.52±11.37º (range: 4.26º to 49.36º). The mean angle between the humeral head axis and ulna diaphysis axis was 61.73º±12.08º (range: 33.97º to 86.37º). The mean torsion angle was 62.58º±11.28 º (range: 40.74º to 85.74º). Measurement and utilization of the relationship between the bicipital groove, ulna diaphysis and transepicondylar axes may be used for restoring humeral rotation.

  18. Effects of humeral intraosseous versus intravenous epinephrine on pharmacokinetics and return of spontaneous circulation in a porcine cardiac arrest model: A randomized control trial.

    Science.gov (United States)

    Johnson, Don; Garcia-Blanco, Jose; Burgert, James; Fulton, Lawrence; Kadilak, Patrick; Perry, Katherine; Burke, Jeffrey

    2015-09-01

    Cardiopulmonary Resuscitation (CPR), defibrillation, and epinephrine administration are pillars of advanced cardiac life support (ACLS). Intraosseous (IO) access is an alternative route for epinephrine administration when intravenous (IV) access is unobtainable. Previous studies indicate the pharmacokinetics of epinephrine administration via IO and IV routes differ, but it is not known if the difference influences return of spontaneous circulation (ROSC). The purpose of this prospective, experimental study was to determine the effects of humeral IO (HIO) and IV epinephrine administration during cardiac arrest on pharmacokinetics, ROSC, and odds of survival. Swine (N = 21) were randomized into 3 groups: humeral IO (HIO), peripheral IV (IV) and CPR/defibrillation control. Cardiac arrest was induced under general anesthesia. The swine remained in arrest for 2 min without intervention. Chest compressions were initiated and continued for 2 min. Epinephrine was administered and serial blood samples collected for pharmacokinetic analysis over 4 min. Defibrillation and epinephrine administration proceeded according to ACLS guidelines continuing for 20 min or until ROSC. Seven HIO swine, 4 IV swine, and no control swine had ROSC. There were no significant differences in ROSC, maximum concentration; except at 30 s, and time-to-concentration-maximum between the HIO and IV groups. Significant differences existed between the experimental groups and the control. The HIO delivers a higher concentration of epinephrine than the IV route at 30 s which may be a survival advantage. Clinicians may consider using the IO route to administer epinephrine during CA when there is no preexisting IV access or when IV access is unobtainable.

  19. Fratura epifisiolise da extremidade proximal do úmero com luxação intratorácica: relato de caso Epiphysiolysis fracture of the proximal end of the humerus with intrathoracic dislocation: a case report

    Directory of Open Access Journals (Sweden)

    Jaime Guiotti Filho

    2008-02-01

    Full Text Available A fratura da extremidade proximal do úmero com luxação intratorácica foi relatada em 1949 por West, em que a fratura era, somente, do tubérculo maior. Desde então, poucos casos foram relatados na literatura, a maioria constituída por pessoas idosas, prevalecendo como indicação terapêutica artroplastia parcial. Os autores relatam o caso de um adolescente de 14 anos de idade, sexo masculino, que apresentou fratura epifisiolise da extremidade proximal do úmero com luxação intratorácica em decorrência de acidente ciclístico e que foi submetido a tratamento cirúrgico com redução, osteossíntese e reinserção do manguito rotador. A recuperação da cabeça do úmero totalmente desvitalizada e o acompanhamento do processo de necrose e revas cularização durante seis anos, em paciente adolescente, parece não terem sido previamente relatados.Fracture of the proximal end of the humerus with intrathoracic dislocation was reported in 1949 by West, and the fracture was only a fracture of the greater tubercle. Few cases have since been published, and most of them in elderly individuals, partial arthroplasty prevailing as the therapy indication. The authors report the case of a 14 year old boy who presented with an epiphysiolysis fracture of the proximal end of the humerus with intrathoracic dislocation resulting from a bicycle accident. The boy was submitted to surgical treatment with reduction, osteosynthesis, and reinsertion of the rotator cuff. The totally devitalized humeral head recovery and the monitoring of the necrosis and revascularization process for a period of six years in a teenager patient seems to have never been reported before.

  20. High prevalence of simultaneous rib and vertebral fractures in patients with hip fracture.

    Science.gov (United States)

    Lee, Bong-Gun; Sung, Yoon-Kyoung; Kim, Dam; Choi, Yun Young; Kim, Hunchul; Kim, Yeesuk

    2017-02-01

    The purpose was to evaluate the prevalence and location of simultaneous fracture using bone scans in patients with hip fracture and to determine the risk factors associated with simultaneous fracture. One hundred eighty two patients with hip fracture were reviewed for this study. Clinical parameters and bone mineral density (BMD) of the lumbar vertebra and femoral neck were investigated. To identify acute simultaneous fracture, a bone scan was performed at 15.4±4.1days after hip fracture. The prevalence and location of simultaneous fracture were evaluated, and multivariate logistic regression analysis was performed to determine the risk factors. Simultaneous fracture was observed in 102 of 182 patients, a prevalence of 56.0%. Rib fracture was the most common type of simultaneous fracture followed by rib with vertebral fracture. The BMD of the lumbar vertebra was significantly lower in patients with simultaneous fracture (p=0.044) and was identified as an independent risk factor (odds ratio: OR 0.05, 95% confidence interval: CI 0.01-0.57). The prevalence of simultaneous fracture was relatively high among patients with hip fracture, and BMD was significantly lower in patients with simultaneous fracture than in patients without it. Surgeons should be aware of the possibility of simultaneous fracture in patients with hip fracture. Copyright © 2016 Elsevier Ltd. All rights reserved.