  1. An Exoskeleton Robot for Human Forearm and Wrist Motion Assist

    Science.gov (United States)

    Ranathunga Arachchilage Ruwan Chandra Gopura; Kiguchi, Kazuo

    The exoskeleton robot is worn by the human operator as an orthotic device. Its joints and links correspond to those of the human body. The same system operated in different modes can be used for different fundamental applications; a human-amplifier, haptic interface, rehabilitation device and assistive device sharing a portion of the external load with the operator. We have been developing exoskeleton robots for assisting the motion of physically weak individuals such as elderly or slightly disabled in daily life. In this paper, we propose a three degree of freedom (3DOF) exoskeleton robot (W-EXOS) for the forearm pronation/ supination motion, wrist flexion/extension motion and ulnar/radial deviation. The paper describes the wrist anatomy toward the development of the exoskeleton robot, the hardware design of the exoskeleton robot and EMG-based control method. The skin surface electromyographic (EMG) signals of muscles in forearm of the exoskeletons' user and the hand force/forearm torque are used as input information for the controller. By applying the skin surface EMG signals as main input signals to the controller, automatic control of the robot can be realized without manipulating any other equipment. Fuzzy control method has been applied to realize the natural and flexible motion assist. Experiments have been performed to evaluate the proposed exoskeleton robot and its control method.

  2. 3D pose estimation and motion analysis of the articulated human hand-forearm limb in an industrial production environment

    Science.gov (United States)

    Hahn, Markus; Barrois, Björn; Krüger, Lars; Wöhler, Christian; Sagerer, Gerhard; Kummert, Franz

    2010-09-01

    This study introduces an approach to model-based 3D pose estimation and instantaneous motion analysis of the human hand-forearm limb in the application context of safe human-robot interaction. 3D pose estimation is performed using two approaches: The Multiocular Contracting Curve Density (MOCCD) algorithm is a top-down technique based on pixel statistics around a contour model projected into the images from several cameras. The Iterative Closest Point (ICP) algorithm is a bottom-up approach which uses a motion-attributed 3D point cloud to estimate the object pose. Due to their orthogonal properties, a fusion of these algorithms is shown to be favorable. The fusion is performed by a weighted combination of the extracted pose parameters in an iterative manner. The analysis of object motion is based on the pose estimation result and the motion-attributed 3D points belonging to the hand-forearm limb using an extended constraint-line approach which does not rely on any temporal filtering. A further refinement is obtained using the Shape Flow algorithm, a temporal extension of the MOCCD approach, which estimates the temporal pose derivative based on the current and the two preceding images, corresponding to temporal filtering with a short response time of two or at most three frames. Combining the results of the two motion estimation stages provides information about the instantaneous motion properties of the object. Experimental investigations are performed on real-world image sequences displaying several test persons performing different working actions typically occurring in an industrial production scenario. In all example scenes, the background is cluttered, and the test persons wear various kinds of clothes. For evaluation, independently obtained ground truth data are used. [Figure not available: see fulltext.

  3. Forearm Range of Motion in Australovenator wintonensis (Theropoda, Megaraptoridae.

    Directory of Open Access Journals (Sweden)

    Matt A White

    Full Text Available The hypertrophied manual claws and modified manus of megaraptoran theropods represent an unusual morphological adaptation among carnivorous dinosaurs. The skeleton of Australovenator wintonensis from the Cenomanian of Australia is among the most complete of any megaraptorid. It presents the opportunity to examine the range of motion of its forearm and the function of its highly modified manus. This provides the basis for behavioural inferences, and comparison with other Gondwanan theropod groups. Digital models created from computed tomography scans of the holotype reveal a humerus range of motion that is much greater than Allosaurus, Acrocanthosaurus, Tyrannosaurus but similar to that of the dromaeosaurid Bambiraptor. During flexion, the radius was forced distally by the radial condyle of the humerus. This movement is here suggested as a mechanism that forced a medial movement of the wrist. The antebrachium possessed a range of motion that was close to dromaeosaurids; however, the unguals were capable of hyper-extension, in particular manual phalanx I-2, which is a primitive range of motion characteristic seen in allosaurids and Dilophosaurus. During flexion, digits I and II slightly converge and diverge when extended which is accentuated by hyperextension of the digits in particular the unguals. We envision that prey was dispatched by its hands and feet with manual phalanx I-2 playing a dominant role. The range of motion analysis neither confirms nor refutes current phylogenetic hypotheses with regards to the placement of Megaraptoridae; however, we note Australovenator possessed, not only a similar forearm range of motion to some maniraptorans and basal coelurosaurs, but also similarities with Tetanurans (Allosauroids and Dilophosaurus.

  4. A restrained-torque-based motion instructor: forearm flexion/extension-driving exoskeleton

    Science.gov (United States)

    Nishimura, Takuya; Nomura, Yoshihiko; Sakamoto, Ryota

    2013-01-01

    When learning complicated movements by ourselves, we encounter such problems as a self-rightness. The self-rightness results in a lack of detail and objectivity, and it may cause to miss essences and even twist the essences. Thus, we sometimes fall into the habits of doing inappropriate motions. To solve these problems or to alleviate the problems as could as possible, we have been developed mechanical man-machine human interfaces to support us learning such motions as cultural gestures and sports form. One of the promising interfaces is a wearable exoskeleton mechanical system. As of the first try, we have made a prototype of a 2-link 1-DOF rotational elbow joint interface that is applied for teaching extension-flexion operations with forearms and have found its potential abilities for teaching the initiating and continuing flection motion of the elbow.

  5. 3D Measurement of Forearm and Upper Arm during Throwing Motion using Body Mounted Sensor

    Science.gov (United States)

    Koda, Hideharu; Sagawa, Koichi; Kuroshima, Kouta; Tsukamoto, Toshiaki; Urita, Kazutaka; Ishibashi, Yasuyuki

    The aim of this study is to propose the measurement method of three-dimensional (3D) movement of forearm and upper arm during pitching motion of baseball using inertial sensors without serious consideration of sensor installation. Although high accuracy measurement of sports motion is achieved by using optical motion capture system at present, it has some disadvantages such as the calibration of cameras and limitation of measurement place. Whereas the proposed method for 3D measurement of pitching motion using body mounted sensors provides trajectory and orientation of upper arm by the integration of acceleration and angular velocity measured on upper limb. The trajectory of forearm is derived so that the elbow joint axis of forearm corresponds to that of upper arm. Spatial relation between upper limb and sensor system is obtained by performing predetermined movements of upper limb and utilizing angular velocity and gravitational acceleration. The integration error is modified so that the estimated final position, velocity and posture of upper limb agree with the actual ones. The experimental results of the measurement of pitching motion show that trajectories of shoulder, elbow and wrist estimated by the proposed method are highly correlated to those from the motion capture system within the estimation error of about 10 [%].

  6. Tracking blood vessels in human forearms using visual servoing

    DEFF Research Database (Denmark)

    Savarimuthu, Thiusius Rajeeth; Ellekilde, Lars-Peter; Hansen, Morten

    compensation. By using images taken with near-infrared light to locate the blood vessels in a human forearm and using the same images to detects movements of the arm, this paper shows that it is possible make a robot arm, potentially equipped with a needle for drawing the blood, compensate for the movements......Drawing an average of more than 2 blood sample per Danish citizen per year increases the demand for an automatic blood sampling method. This paper presents a proof of concept to one of the main challenges in making a fully automated blood sampling procedure, namely: the patient movement...

  7. Microwave Imaging of Human Forearms: Pilot Study and Image Enhancement

    Directory of Open Access Journals (Sweden)

    Colin Gilmore

    2013-01-01

    Full Text Available We present a pilot study using a microwave tomography system in which we image the forearms of 5 adult male and female volunteers between the ages of 30 and 48. Microwave scattering data were collected at 0.8 to 1.2 GHz with 24 transmitting and receiving antennas located in a matching fluid of deionized water and table salt. Inversion of the microwave data was performed with a balanced version of the multiplicative-regularized contrast source inversion algorithm formulated using the finite-element method (FEM-CSI. T1-weighted MRI images of each volunteer’s forearm were also collected in the same plane as the microwave scattering experiment. Initial “blind” imaging results from the utilized inversion algorithm show that the image quality is dependent on the thickness of the arm’s peripheral adipose tissue layer; thicker layers of adipose tissue lead to poorer overall image quality. Due to the exible nature of the FEM-CSI algorithm used, prior information can be readily incorporated into the microwave imaging inversion process. We show that by introducing prior information into the FEM-CSI algorithm the internal anatomical features of all the arms are resolved, significantly improving the images. The prior information was estimated manually from the blind inversions using an ad hoc procedure.

  8. MODELING OF THERMOELECTRIC SYSTEM FOR LOCAL THERMAL EFFECTS ON HUMAN FOREARM ZONE

    Directory of Open Access Journals (Sweden)

    T. A. Ismailov

    2013-01-01

    Full Text Available In this paper we consider a model of the thermoelectric system for the thermal effect on the human forearm. The model is implemented on the basis of numerical solution of differentialequations of heat conduction for bodies of complex configuration. Two-dimensional and onedimensional graphs of the temperature change in different zones of the object of exposure aregiven.

  9. Human motion simulation predictive dynamics

    CERN Document Server

    Abdel-Malek, Karim

    2013-01-01

    Simulate realistic human motion in a virtual world with an optimization-based approach to motion prediction. With this approach, motion is governed by human performance measures, such as speed and energy, which act as objective functions to be optimized. Constraints on joint torques and angles are imposed quite easily. Predicting motion in this way allows one to use avatars to study how and why humans move the way they do, given specific scenarios. It also enables avatars to react to infinitely many scenarios with substantial autonomy. With this approach it is possible to predict dynamic motion without having to integrate equations of motion -- rather than solving equations of motion, this approach solves for a continuous time-dependent curve characterizing joint variables (also called joint profiles) for every degree of freedom. Introduces rigorous mathematical methods for digital human modelling and simulation Focuses on understanding and representing spatial relationships (3D) of biomechanics Develops an i...

  10. Monosynaptic Ia projections from intrinsic hand muscles to forearm motoneurones in humans.

    Science.gov (United States)

    Marchand-Pauvert, V; Nicolas, G; Pierrot-Deseilligny, E

    2000-05-15

    Heteronymous Ia excitatory projections from intrinsic hand muscles to human forearm motoneurones (MNs) were investigated. Changes in firing probability of single motor units (MUs) in the flexor carpi radialis (FCR), flexor carpi ulnaris (FCU), flexor digitorum superficialis (FDS), extensor carpi radialis (ECR), extensor carpi ulnaris (ECU) and extensor digitorum communis (EDC) were studied after electrical stimuli were applied to the median and ulnar nerve at wrist level and to the corresponding homonymous nerve at elbow level. Homonymous facilitation, occurring at the same latency as the H reflex, and therefore attributed to monosynaptic Ia EPSPs, was found in all the sampled units. In many MUs an early facilitation was also evoked by heteronymous low-threshold afferents from intrinsic hand muscles. The low threshold (between 0.5 and 0.6 times motor threshold (MT)) and the inability of a pure cutaneous stimulation to reproduce this effect indicate that it is due to stimulation of group I muscle afferents. Evidence for a similar central delay (monosynaptic) in heteronymous as in homonymous pathways was accepted when the difference in latencies of the homonymous and heteronymous peaks did not differ from the estimated supplementary afferent conduction time from wrist to elbow level by more than 0.5 ms (conduction velocity in the fastest Ia afferents between wrist and elbow levels being equal to 69 m s-1). A statistically significant heteronymous monosynaptic Ia excitation from intrinsic hand muscles supplied by both median and ulnar nerves was found in MUs belonging to all forearm motor nuclei tested (although not in ECU MUs after ulnar stimulation). It was, however, more often found in flexors than in extensors, in wrist than in finger muscles and in muscles operating in the radial than in the ulnar side. It is argued that the connections of Ia afferents from intrinsic hand muscles to forearm MNs, which are stronger and more widely distributed than in the cat

  11. Virtual Reality Anatomy: Is It Comparable with Traditional Methods in the Teaching of Human Forearm Musculoskeletal Anatomy?

    Science.gov (United States)

    Codd, Anthony M.; Choudhury, Bipasha

    2011-01-01

    The use of cadavers to teach anatomy is well established, but limitations with this approach have led to the introduction of alternative teaching methods. One such method is the use of three-dimensional virtual reality computer models. An interactive, three-dimensional computer model of human forearm anterior compartment musculoskeletal anatomy…

  12. Real-time contrast imaging: a new method to monitor capillary recruitment in human forearm skeletal muscle.

    NARCIS (Netherlands)

    Mulder, A.H.; Dijk, A.P.J. van; Smits, P.; Tack, C.J.J.

    2008-01-01

    OBJECTIVE: Muscle capillary perfusion can be measured by contrast-enhanced ultrasound. We examined whether a less time-consuming ultrasound technique, called "real-time imaging," could be used to measure capillary recruitment in human forearm skeletal muscle. METHODS: We measured microvascular blood

  13. Marker-Free Human Motion Capture

    DEFF Research Database (Denmark)

    Grest, Daniel

    Human Motion Capture is a widely used technique to obtain motion data for animation of virtual characters. Commercial optical motion capture systems are marker-based. This book is about marker-free motion capture and its possibilities to acquire motion from a single viewing direction. The focus...

  14. Local forearm and whole-body respiratory quotient in humans after an oral glucose load

    DEFF Research Database (Denmark)

    Simonsen, L; Bülow, J; Madsen, J

    1993-01-01

    the glucose load and had not returned to baseline level at the end of the experiment. Whole-body respiratory quotient (RQ) was, on average, 0.80 (SD 0.05) in the baseline condition and increased to a maximum of 0.91 (0.03) and then decreased to baseline level at the end of the experiment. The local forearm.......17) to 0.63 (0.17) 30 min after the glucose load (P glucose load RQ increased to a maximum level at 0.95 (0.22) and decreased then gradually to baseline level. The experiments emphasize several methodological problems in the measurement of local forearm RQ. The whole-body RQ......The effects of an oral glucose load of 75 g on the local forearm and whole-body energy thermogenesis were measured in normal subjects during the 4 h after the glucose intake. Simultaneous assessment of substrate metabolism in the forearm was performed. Energy expenditure (EE) increased after...

  15. Pain, wheal and flare in human forearm skin induced by bradykinin and 5-hydroxytryptamine

    DEFF Research Database (Denmark)

    Jensen, Kai; Tuxen, C; Pedersen-Bjergaard, U

    1990-01-01

    Pain was induced in 19 healthy individuals by double-blind injections into the forearm skin of 0.05 ml of physiological saline with or without active substances added. Bradykinin (0.5 nmol), 5-hydroxytryptamine (0.5 nmol) and a mixture of the two substances in half dosage (0.25 nmol + 0.25 nmol...

  16. Three-dimensional imaging of human cutaneous forearm bite marks in human volunteers over a 4 day period.

    Science.gov (United States)

    de Sainte Croix, M M; Gauld, D; Forgie, A H; Lowe, R

    2016-05-01

    Human bite marks are often sustained during sexual, domestic or child abuse. Currently, analysis of these marks involves digital photography techniques along with an expert forensic odontologist opinion. Photographs often focus closely on the bite mark and give little context to the anatomical location of the injury. Due to variation in camera models and expertise of the photographer, photograph quality can affect its interpretation. Additionally, it can sometimes be days between injury and examination, allowing the injury pattern and colour to alter, making it harder to analyse. To investigate if a 3D imaging technique, creating a time-lapse image of a bite mark in three dimensions, can provide context to the injury in terms of nature and location, and also allow analysis of the change in appearance of a bite mark over time. Participants had an experimental bite mark produced on their forearm by dental casts mounted on a dental articulator. The forearms were photographed immediately following the bite, and at intervals of 3, 6, 24, 48, 72 and 96 h. A DI3D(®) (Dimensional Imaging 3D) photogrammetry system and Autodesk Maya 2015(®) software was used to create a 3D animation from the images obtained. The clearest, long lasting bite mark injuries were selected for animation, enabling the 3D imaging technique to be used optimally. 3D time-lapse animations were successfully created with the ability to be viewed on most electronic devices. With further refinement this technique could be valuable in a number of areas. We anticipate animations produced in this way to have significant benefit to the presentation of photographic evidence in a court setting, and in age estimation of injuries. Copyright © 2016 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  17. Polymorphisms of the human IL-1 receptor antagonist gene and forearm bone mineral density in postmenopausal women

    Directory of Open Access Journals (Sweden)

    Jivka T Ivanova

    2012-01-01

    Full Text Available Context: Studies on the human interleukin 1 receptor antagonist (IL-1RA gene polymorphism have provided conflicting data regarding the bone mass and quality. Aim and Design: The objective of this case-control study was to investigate the association between the forearm bone mineral density (BMD and the IL1RA gene polymorphisms. Materials and Methods: A total of 400 postmenopausal Bulgarian women participated in this study. BMD was measured at the forearm by X-ray absorptiometry on a DTX-100 device (Osteometer Meditech, USA. A PCR product was isolated. The alleles were scored according to their length: A1 - 410 bp - 4 repeats; A2 - 240 bp - 2 repeats; A3 - 500 bp - 5 repeats; A4 - 325 bp - 3 repeats; A5 - 595 bp - 6 repeats. All analyses were evaluated for statistical significance (χ2 -test and T-test. Results: Four alleles were observed - A1, A2, A3, and A4. The A1A1 genotype was more common in cases with low BMD than in controls with normal BMD (95% vs. 90%, χ2 P < 0.01. The A2A2 genotype was equally distributed among cases and controls (both 5%. The other two genotypes (A3A3 and A4A4 as well as A1A3 were present only in controls with normal BMD. The A2A2 genotype was associated with higher BMD and the A1A1 - with lower BMD at both forearm sites. The odds ratio for low BMD in the presence of the A1A1 genotype was 2.11. The etiological factor reflecting the association between the polymorphism and the disease was 0.50. In our study sample the IL1RA genetic polymorphisms were associated with the forearm BMD. Conclusion: This genetic polymorphism may become a useful genetic marker for the study of osteoporosis.

  18. Median artery of the forearm in human fetuses in northeastern Brazil: anatomical study and review of the literature.

    Science.gov (United States)

    Aragão, José Aderval; da Silva, Ana Caroline Ferreira; Anunciação, Caio Barretto; Reis, Francisco Prado

    2017-01-01

    A persistent median artery is a rare anomaly. It accompanies the median nerve along its course in the forearm and is of variable origin. It is associated with other local anatomical variations and may contribute significantly towards formation of the superficial palmar arch. In embryos, it is responsible mainly for the blood supply to the hand. The objective of this study was to research the frequency, type (forearm or palmar) and origin of the median artery in fetuses, correlating its presence with sex and body side. Red-colored latex was injected into 32 brachial arteries of human fetuses until its arrival in the hand could be seen. Twenty-four hours after the injection, the median arteries were dissected without the aid of optical instruments. Among the 32 forearms dissected, the median artery was present in 81.25 % (26) of the cases, and it was found more frequently in females and on the left side. Regarding origin, most of the median arteries originated in the common interosseous artery (38.5 %) and anterior interosseous artery (34.6 %). The mean length of the median arteries was 21.1 mm for the palmar type and 19.8 mm for the forearm type. The median artery has a high rate of persistence. It is important to be aware of this anatomical variation, since its presence may give rise to difficulties during routine surgical procedures on the wrist. Its presence may cause serious functional complications in the carpal tunnel, anterior interosseous nerve, round pronator syndromes, and ischemia of the hand.

  19. Methodological assessment of skin and limb blood flows in the human forearm during thermal and baroreceptor provocations

    OpenAIRE

    Brothers, R. Matthew; Wingo, Jonathan E.; Hubing, Kimberly A.; Crandall, Craig G.

    2010-01-01

    Skin blood flow responses in the human forearm, assessed by three commonly used technologies—single-point laser-Doppler flowmetry, integrated laser-Doppler flowmetry, and laser-Doppler imaging—were compared in eight subjects during normothermic baseline, acute skin-surface cooling, and whole body heat stress (Δ internal temperature = 1.0 ± 0.2°C; P < 0.001). In addition, while normothermic and heat stressed, subjects were exposed to 30-mmHg lower-body negative pressure (LBNP). Skin blood flow...

  20. Multi-model approach to characterize human handwriting motion.

    Science.gov (United States)

    Chihi, I; Abdelkrim, A; Benrejeb, M

    2016-02-01

    This paper deals with characterization and modelling of human handwriting motion from two forearm muscle activity signals, called electromyography signals (EMG). In this work, an experimental approach was used to record the coordinates of a pen tip moving on the (x, y) plane and EMG signals during the handwriting act. The main purpose is to design a new mathematical model which characterizes this biological process. Based on a multi-model approach, this system was originally developed to generate letters and geometric forms written by different writers. A Recursive Least Squares algorithm is used to estimate the parameters of each sub-model of the multi-model basis. Simulations show good agreement between predicted results and the recorded data.

  1. Effect of repeated forearm muscle cooling on the adaptation of skeletal muscle metabolism in humans

    Science.gov (United States)

    Wakabayashi, Hitoshi; Nishimura, Takayuki; Wijayanto, Titis; Watanuki, Shigeki; Tochihara, Yutaka

    2017-07-01

    This study aimed to investigate the effect of repeated cooling of forearm muscle on adaptation in skeletal muscle metabolism. It is hypothesized that repeated decreases of muscle temperature would increase the oxygen consumption in hypothermic skeletal muscle. Sixteen healthy males participated in this study. Their right forearm muscles were locally cooled to 25 °C by cooling pads attached to the skin. This local cooling was repeated eight times on separate days for eight participants (experimental group), whereas eight controls received no cold exposure. To evaluate adaptation in skeletal muscle metabolism, a local cooling test was conducted before and after the repeated cooling period. Change in oxy-hemoglobin content in the flexor digitorum at rest and during a 25-s isometric handgrip (10% maximal voluntary construction) was measured using near-infrared spectroscopy at every 2 °C reduction in forearm muscle temperature. The arterial blood flow was occluded for 15 s by upper arm cuff inflation at rest and during the isometric handgrip. The oxygen consumption in the flexor digitorum muscle was evaluated by a slope of the oxy-hemoglobin change during the arterial occlusion. In the experimental group, resting oxygen consumption in skeletal muscle did not show any difference between pre- and post-intervention, whereas muscle oxygen consumption during the isometric handgrip was significantly higher in post-intervention than in pre-test from thermoneutral baseline to 31 °C muscle temperature ( P cooling might facilitate oxidative metabolism in the skeletal muscle. In summary, skeletal muscle metabolism during submaximal isometric handgrip was facilitated after repeated local muscle cooling.

  2. Example-based human motion denoising.

    Science.gov (United States)

    Lou, Hui; Chai, Jinxiang

    2010-01-01

    With the proliferation of motion capture data, interest in removing noise and outliers from motion capture data has increased. In this paper, we introduce an efficient human motion denoising technique for the simultaneous removal of noise and outliers from input human motion data. The key idea of our approach is to learn a series of filter bases from precaptured motion data and use them along with robust statistics techniques to filter noisy motion data. Mathematically, we formulate the motion denoising process in a nonlinear optimization framework. The objective function measures the distance between the noisy input and the filtered motion in addition to how well the filtered motion preserves spatial-temporal patterns embedded in captured human motion data. Optimizing the objective function produces an optimal filtered motion that keeps spatial-temporal patterns in captured motion data. We also extend the algorithm to fill in the missing values in input motion data. We demonstrate the effectiveness of our system by experimenting with both real and simulated motion data. We also show the superior performance of our algorithm by comparing it with three baseline algorithms and to those in state-of-art motion capture data processing software such as Vicon Blade.

  3. Noninvasive measurement of postocclusive parameters in human forearm blood by near infrared spectroscopy

    Science.gov (United States)

    Rao, K. Prahlad; Radhakrishnan, S.; Reddy, M. Ramasubba

    2005-04-01

    Near infrared (NIR) light in the wavelength range from 700 to 900 nm can pass through skin, bone and other tissues relatively easily. As a result, NIR techniques allow a noninvasive assessment of hemoglobin saturation for a wide range of applications, such as in the study of muscle metabolism, the diagnosis of vascular disorders, brain imaging, and breast cancer detection. Near infrared Spectroscopy (NIRS) is an effective tool to measure the hemoglobin concentration in the tissues, which can discriminate optically the oxy- and deoxy- hemoglobin species because of their different near-infrared absorption spectra. We have developed an NIRS probe consisting of a laser diode of 830 nm wavelength and a PIN photodiode in reflectance mode. We have selected a set of healthy volunteers (mean age 30, range 26-40 years) for the study. The probe is placed on forearm of each subject and the backscattered light intensity is measured by occluding the blood flow at 210, 110 and 85 mmHg pressures. Recovery time, peak time and time after 50% release of the cuff pressure are determined from the optical densities during the post occlusive state of forearm. These parameters are useful for determining the transient increase in blood flow after the release of blood occlusion. Clinically, the functional aspects of blood flow in the limbs could be evaluated noninvasively by NIRS.

  4. Comparative Anatomical Analyses of the Forearm Muscles of Cebus libidinosus (Rylands et al. 2000): Manipulatory Behavior and Tool Use

    Science.gov (United States)

    Aversi-Ferreira, Tales Alexandre; Maior, Rafael Souto; Carneiro-e-Silva, Frederico O.; Aversi-Ferreira, Roqueline A. G. M. F.; Tavares, Maria Clotilde; Nishijo, Hisao; Tomaz, Carlos

    2011-01-01

    The present study describes the flexor and extensor muscles in Cebus libidinosus' forearm and compares them with those from humans, chimpanzees and baboons. The data is presented in quantitative anatomical indices for similarity. The capuchin forearm muscles showed important similarities with chimpanzees and humans, particularly those that act on thumb motion and allow certain degree of independence from other hand structures, even though their configuration does not enable a true opposable thumb. The characteristics of Cebus' forearm muscles corroborate the evolutionary convergence towards an adaptive behavior (tool use) between Cebus genus and apes. PMID:21789230

  5. The eigenmode analysis of human motion

    International Nuclear Information System (INIS)

    Park, Juyong; Lee, Deok-Sun; González, Marta C

    2010-01-01

    Rapid advances in modern communication technology are enabling the accumulation of large-scale, high-resolution observational data of the spatiotemporal movements of humans. Classification and prediction of human mobility based on the analysis of such data has great potential in applications such as urban planning in addition to being a subject of theoretical interest. A robust theoretical framework is therefore required to study and properly understand human motion. Here we perform the eigenmode analysis of human motion data gathered from mobile communication records, which allows us to explore the scaling properties and characteristics of human motion

  6. A comparative study of vascular injection fluids in fresh-frozen and embalmed human cadaver forearms.

    Science.gov (United States)

    Doomernik, D E; Kruse, R R; Reijnen, M M P J; Kozicz, T L; Kooloos, J G M

    2016-10-01

    Over the years, various vascular injection products have been developed to facilitate anatomical dissections. This study aimed to compare the most commonly used vascular injection products in fresh-frozen and formalin-embalmed cadaver specimens. An overview of the properties, advantages and limitations of each substance was given, and a comparison of vascular infusion procedures in both preservation methods was made. A literature search was performed in order to identify the most commonly used vascular injection products. Acrylic paint, latex, gelatin, silicone, Araldite F and Batson's No. 17 were selected for the study. One fresh-frozen and one embalmed cadaver forearm were infused with each injection product according to a uniform protocol. The curing time, skin- and subcutaneous tissue penetration, degree of filling of the arterial tree, extravasations, consistency of the injected vessels during dissection, and the costs of each injection fluid were noted. There was a large variation between the injection fluids in processing- and curing time, colour intensity, flexibility, fragility, elasticity, strength, toxicity and costs. All fluids were suitable for infusion. The penetration of injection fluid into the skin and subcutaneous tissue was significantly better in fresh-frozen specimens (P = 0.002 and P = 0.009, respectively), with significantly smaller branches casted (P = 0.004). Vascular infusion of fresh-frozen cadaver specimens results in a significantly better filled coloured arterial tree, enabling more detail to be achieved and smaller branches casted. The biomechanical properties of fresh-frozen soft tissues are less affected compared with formalin fixation. All the injection fluids studied are suitable for vascular infusion, but their different properties ensure that certain products and procedures are more suitable for specific study purposes. © 2016 Anatomical Society.

  7. Centralized Networks to Generate Human Body Motions.

    Science.gov (United States)

    Vakulenko, Sergei; Radulescu, Ovidiu; Morozov, Ivan; Weber, Andres

    2017-12-14

    We consider continuous-time recurrent neural networks as dynamical models for the simulation of human body motions. These networks consist of a few centers and many satellites connected to them. The centers evolve in time as periodical oscillators with different frequencies. The center states define the satellite neurons' states by a radial basis function (RBF) network. To simulate different motions, we adjust the parameters of the RBF networks. Our network includes a switching module that allows for turning from one motion to another. Simulations show that this model allows us to simulate complicated motions consisting of many different dynamical primitives. We also use the model for learning human body motion from markers' trajectories. We find that center frequencies can be learned from a small number of markers and can be transferred to other markers, such that our technique seems to be capable of correcting for missing information resulting from sparse control marker settings.

  8. Interactive inverse kinematics for human motion estimation

    DEFF Research Database (Denmark)

    Engell-Nørregård, Morten Pol; Hauberg, Søren; Lapuyade, Jerome

    2009-01-01

    We present an application of a fast interactive inverse kinematics method as a dimensionality reduction for monocular human motion estimation. The inverse kinematics solver deals efficiently and robustly with box constraints and does not suffer from shaking artifacts. The presented motion...... to significantly speed up the particle filtering. It should be stressed that the observation part of the system has not been our focus, and as such is described only from a sense of completeness. With our approach it is possible to construct a robust and computationally efficient system for human motion estimation....

  9. Methodological assessment of skin and limb blood flows in the human forearm during thermal and baroreceptor provocations.

    Science.gov (United States)

    Brothers, R Matthew; Wingo, Jonathan E; Hubing, Kimberly A; Crandall, Craig G

    2010-09-01

    Skin blood flow responses in the human forearm, assessed by three commonly used technologies-single-point laser-Doppler flowmetry, integrated laser-Doppler flowmetry, and laser-Doppler imaging-were compared in eight subjects during normothermic baseline, acute skin-surface cooling, and whole body heat stress (Δ internal temperature=1.0±0.2 degrees C; Pforearm blood flow (FBF) measures obtained using venous occlusion plethysmography and Doppler ultrasound were made during the aforementioned perturbations. Relative to normothermic baseline, skin blood flow decreased during normothermia+LBNP (Pcooling (Peffect of device: P>0.05 for all conditions). Similarly, no differences were identified across all perturbations between FBF measures using plethysmography and Doppler ultrasound (P>0.05 for all perturbations). These data indicate that when normalized to maximum, assessment of skin blood flow in response to vasoconstrictor and dilator perturbations are similar regardless of methodology. Likewise, FBF responses to these perturbations are similar between two commonly used methodologies of limb blood flow assessment.

  10. Human Perception of Ambiguous Inertial Motion Cues

    Science.gov (United States)

    Zhang, Guan-Lu

    2010-01-01

    Human daily activities on Earth involve motions that elicit both tilt and translation components of the head (i.e. gazing and locomotion). With otolith cues alone, tilt and translation can be ambiguous since both motions can potentially displace the otolithic membrane by the same magnitude and direction. Transitions between gravity environments (i.e. Earth, microgravity and lunar) have demonstrated to alter the functions of the vestibular system and exacerbate the ambiguity between tilt and translational motion cues. Symptoms of motion sickness and spatial disorientation can impair human performances during critical mission phases. Specifically, Space Shuttle landing records show that particular cases of tilt-translation illusions have impaired the performance of seasoned commanders. This sensorimotor condition is one of many operational risks that may have dire implications on future human space exploration missions. The neural strategy with which the human central nervous system distinguishes ambiguous inertial motion cues remains the subject of intense research. A prevailing theory in the neuroscience field proposes that the human brain is able to formulate a neural internal model of ambiguous motion cues such that tilt and translation components can be perceptually decomposed in order to elicit the appropriate bodily response. The present work uses this theory, known as the GIF resolution hypothesis, as the framework for experimental hypothesis. Specifically, two novel motion paradigms are employed to validate the neural capacity of ambiguous inertial motion decomposition in ground-based human subjects. The experimental setup involves the Tilt-Translation Sled at Neuroscience Laboratory of NASA JSC. This two degree-of-freedom motion system is able to tilt subjects in the pitch plane and translate the subject along the fore-aft axis. Perception data will be gathered through subject verbal reports. Preliminary analysis of perceptual data does not indicate that

  11. Robotics-based synthesis of human motion

    KAUST Repository

    Khatib, O.; Demircan, E.; De Sapio, V.; Sentis, L.; Besier, T.; Delp, S.

    2009-01-01

    The synthesis of human motion is a complex procedure that involves accurate reconstruction of movement sequences, modeling of musculoskeletal kinematics, dynamics and actuation, and characterization of reliable performance criteria. Many of these processes have much in common with the problems found in robotics research. Task-based methods used in robotics may be leveraged to provide novel musculoskeletal modeling methods and physiologically accurate performance predictions. In this paper, we present (i) a new method for the real-time reconstruction of human motion trajectories using direct marker tracking, (ii) a task-driven muscular effort minimization criterion and (iii) new human performance metrics for dynamic characterization of athletic skills. Dynamic motion reconstruction is achieved through the control of a simulated human model to follow the captured marker trajectories in real-time. The operational space control and real-time simulation provide human dynamics at any configuration of the performance. A new criteria of muscular effort minimization has been introduced to analyze human static postures. Extensive motion capture experiments were conducted to validate the new minimization criterion. Finally, new human performance metrics were introduced to study in details an athletic skill. These metrics include the effort expenditure and the feasible set of operational space accelerations during the performance of the skill. The dynamic characterization takes into account skeletal kinematics as well as muscle routing kinematics and force generating capacities. The developments draw upon an advanced musculoskeletal modeling platform and a task-oriented framework for the effective integration of biomechanics and robotics methods.

  12. Robotics-based synthesis of human motion

    KAUST Repository

    Khatib, O.

    2009-05-01

    The synthesis of human motion is a complex procedure that involves accurate reconstruction of movement sequences, modeling of musculoskeletal kinematics, dynamics and actuation, and characterization of reliable performance criteria. Many of these processes have much in common with the problems found in robotics research. Task-based methods used in robotics may be leveraged to provide novel musculoskeletal modeling methods and physiologically accurate performance predictions. In this paper, we present (i) a new method for the real-time reconstruction of human motion trajectories using direct marker tracking, (ii) a task-driven muscular effort minimization criterion and (iii) new human performance metrics for dynamic characterization of athletic skills. Dynamic motion reconstruction is achieved through the control of a simulated human model to follow the captured marker trajectories in real-time. The operational space control and real-time simulation provide human dynamics at any configuration of the performance. A new criteria of muscular effort minimization has been introduced to analyze human static postures. Extensive motion capture experiments were conducted to validate the new minimization criterion. Finally, new human performance metrics were introduced to study in details an athletic skill. These metrics include the effort expenditure and the feasible set of operational space accelerations during the performance of the skill. The dynamic characterization takes into account skeletal kinematics as well as muscle routing kinematics and force generating capacities. The developments draw upon an advanced musculoskeletal modeling platform and a task-oriented framework for the effective integration of biomechanics and robotics methods.

  13. Generating Concise Rules for Human Motion Retrieval

    Science.gov (United States)

    Mukai, Tomohiko; Wakisaka, Ken-Ichi; Kuriyama, Shigeru

    This paper proposes a method for retrieving human motion data with concise retrieval rules based on the spatio-temporal features of motion appearance. Our method first converts motion clip into a form of clausal language that represents geometrical relations between body parts and their temporal relationship. A retrieval rule is then learned from the set of manually classified examples using inductive logic programming (ILP). ILP automatically discovers the essential rule in the same clausal form with a user-defined hypothesis-testing procedure. All motions are indexed using this clausal language, and the desired clips are retrieved by subsequence matching using the rule. Such rule-based retrieval offers reasonable performance and the rule can be intuitively edited in the same language form. Consequently, our method enables efficient and flexible search from a large dataset with simple query language.

  14. Forearm metabolism during infusion of adrenaline

    DEFF Research Database (Denmark)

    Simonsen, L; Stefl, B; Bülow, J

    2000-01-01

    Human skeletal muscle metabolism is often investigated by measurements of substrate fluxes across the forearm. To evaluate whether the two forearms give the same metabolic information, nine healthy subjects were studied in the fasted state and during infusion of adrenaline. Both arms were...... catheterized in a cubital vein in the retrograde direction. A femoral artery was catheterized for blood sampling, and a femoral vein for infusion of adrenaline. Forearm blood flow was measured by venous occlusion strain-gauge plethysmography. Forearm subcutaneous adipose tissue blood flow was measured...... by the local 133Xe washout method. Metabolic fluxes were calculated as the product of forearm blood flow and a-v differences of metabolite concentrations. After baseline measurements, adrenaline was infused at a rate of 0.3 nmol kg-1 min-1. No difference in the metabolic information obtained in the fasting...

  15. Human sensitivity to vertical self-motion.

    Science.gov (United States)

    Nesti, Alessandro; Barnett-Cowan, Michael; Macneilage, Paul R; Bülthoff, Heinrich H

    2014-01-01

    Perceiving vertical self-motion is crucial for maintaining balance as well as for controlling an aircraft. Whereas heave absolute thresholds have been exhaustively studied, little work has been done in investigating how vertical sensitivity depends on motion intensity (i.e., differential thresholds). Here we measure human sensitivity for 1-Hz sinusoidal accelerations for 10 participants in darkness. Absolute and differential thresholds are measured for upward and downward translations independently at 5 different peak amplitudes ranging from 0 to 2 m/s(2). Overall vertical differential thresholds are higher than horizontal differential thresholds found in the literature. Psychometric functions are fit in linear and logarithmic space, with goodness of fit being similar in both cases. Differential thresholds are higher for upward as compared to downward motion and increase with stimulus intensity following a trend best described by two power laws. The power laws' exponents of 0.60 and 0.42 for upward and downward motion, respectively, deviate from Weber's Law in that thresholds increase less than expected at high stimulus intensity. We speculate that increased sensitivity at high accelerations and greater sensitivity to downward than upward self-motion may reflect adaptations to avoid falling.

  16. Stretch sensors for human body motion

    Science.gov (United States)

    O'Brien, Ben; Gisby, Todd; Anderson, Iain A.

    2014-03-01

    Sensing motion of the human body is a difficult task. From an engineers' perspective people are soft highly mobile objects that move in and out of complex environments. As well as the technical challenge of sensing, concepts such as comfort, social intrusion, usability, and aesthetics are paramount in determining whether someone will adopt a sensing solution or not. At the same time the demands for human body motion sensing are growing fast. Athletes want feedback on posture and technique, consumers need new ways to interact with augmented reality devices, and healthcare providers wish to track recovery of a patient. Dielectric elastomer stretch sensors are ideal for bridging this gap. They are soft, flexible, and precise. They are low power, lightweight, and can be easily mounted on the body or embedded into clothing. From a commercialisation point of view stretch sensing is easier than actuation or generation - such sensors can be low voltage and integrated with conventional microelectronics. This paper takes a birds-eye view of the use of these sensors to measure human body motion. A holistic description of sensor operation and guidelines for sensor design will be presented to help technologists and developers in the space.

  17. Articulated Human Motion Tracking Using Sequential Immune Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    Yi Li

    2013-01-01

    Full Text Available We formulate human motion tracking as a high-dimensional constrained optimization problem. A novel generative method is proposed for human motion tracking in the framework of evolutionary computation. The main contribution is that we introduce immune genetic algorithm (IGA for pose optimization in latent space of human motion. Firstly, we perform human motion analysis in the learnt latent space of human motion. As the latent space is low dimensional and contents the prior knowledge of human motion, it makes pose analysis more efficient and accurate. Then, in the search strategy, we apply IGA for pose optimization. Compared with genetic algorithm and other evolutionary methods, its main advantage is the ability to use the prior knowledge of human motion. We design an IGA-based method to estimate human pose from static images for initialization of motion tracking. And we propose a sequential IGA (S-IGA algorithm for motion tracking by incorporating the temporal continuity information into the traditional IGA. Experimental results on different videos of different motion types show that our IGA-based pose estimation method can be used for initialization of motion tracking. The S-IGA-based motion tracking method can achieve accurate and stable tracking of 3D human motion.

  18. Clinical application of advances in elbow and forearm anatomy and biomechanics.

    Science.gov (United States)

    Zimmerman, Neal B

    2002-02-01

    The static and dynamic stabilizers of the elbow and forearm axis are closely interrelated in elbow and forearm unit motion and load handling. An [figure: see text] understanding of elbow and forearm anatomy is crucial to the surgeon evaluating and treating complex pathologies resulting from acute or remote trauma.

  19. Dielectric polymer: scavenging energy from human motion

    Science.gov (United States)

    Jean-Mistral, Claire; Basrour, Skandar; Chaillout, Jean-Jacques

    2008-03-01

    More and more sensors are embedded in human body for medical applications, for sport. The short lifetime of the batteries, available on the market, reveals a real problem of autonomy of these systems. A promising alternative is to scavenge the ambient energy such as the mechanical one. Up to now, few scavenging structures have operating frequencies compatible with ambient one. And, most of the developed structures are rigid and use vibration as mechanical source. For these reasons, we developed a scavenger that operates in a large frequency spectrum from quasi-static to dynamic range. This generator is fully flexible, light and does not hamper the human motion. Thus, we report in this paper an analytical model for dielectric generator with news electrical and mechanical characterization, and the development of an innovating application: scavenging energy from human motion. The generator is located on the knee and design to scavenge 0.1mJ per scavenging cycle at a frequency of 1Hz, enough to supply a low consumption system and with a poling voltage as low as possible to facilitate the power management. Our first prototype is a membrane with an area of 5*3cm and 31µm in thickness which scavenge 0.1mJ under 170V at constant charge Q.

  20. MotionExplorer: exploratory search in human motion capture data based on hierarchical aggregation.

    Science.gov (United States)

    Bernard, Jürgen; Wilhelm, Nils; Krüger, Björn; May, Thorsten; Schreck, Tobias; Kohlhammer, Jörn

    2013-12-01

    We present MotionExplorer, an exploratory search and analysis system for sequences of human motion in large motion capture data collections. This special type of multivariate time series data is relevant in many research fields including medicine, sports and animation. Key tasks in working with motion data include analysis of motion states and transitions, and synthesis of motion vectors by interpolation and combination. In the practice of research and application of human motion data, challenges exist in providing visual summaries and drill-down functionality for handling large motion data collections. We find that this domain can benefit from appropriate visual retrieval and analysis support to handle these tasks in presence of large motion data. To address this need, we developed MotionExplorer together with domain experts as an exploratory search system based on interactive aggregation and visualization of motion states as a basis for data navigation, exploration, and search. Based on an overview-first type visualization, users are able to search for interesting sub-sequences of motion based on a query-by-example metaphor, and explore search results by details on demand. We developed MotionExplorer in close collaboration with the targeted users who are researchers working on human motion synthesis and analysis, including a summative field study. Additionally, we conducted a laboratory design study to substantially improve MotionExplorer towards an intuitive, usable and robust design. MotionExplorer enables the search in human motion capture data with only a few mouse clicks. The researchers unanimously confirm that the system can efficiently support their work.

  1. MotionFlow: Visual Abstraction and Aggregation of Sequential Patterns in Human Motion Tracking Data.

    Science.gov (United States)

    Jang, Sujin; Elmqvist, Niklas; Ramani, Karthik

    2016-01-01

    Pattern analysis of human motions, which is useful in many research areas, requires understanding and comparison of different styles of motion patterns. However, working with human motion tracking data to support such analysis poses great challenges. In this paper, we propose MotionFlow, a visual analytics system that provides an effective overview of various motion patterns based on an interactive flow visualization. This visualization formulates a motion sequence as transitions between static poses, and aggregates these sequences into a tree diagram to construct a set of motion patterns. The system also allows the users to directly reflect the context of data and their perception of pose similarities in generating representative pose states. We provide local and global controls over the partition-based clustering process. To support the users in organizing unstructured motion data into pattern groups, we designed a set of interactions that enables searching for similar motion sequences from the data, detailed exploration of data subsets, and creating and modifying the group of motion patterns. To evaluate the usability of MotionFlow, we conducted a user study with six researchers with expertise in gesture-based interaction design. They used MotionFlow to explore and organize unstructured motion tracking data. Results show that the researchers were able to easily learn how to use MotionFlow, and the system effectively supported their pattern analysis activities, including leveraging their perception and domain knowledge.

  2. Human motion sensing and recognition a fuzzy qualitative approach

    CERN Document Server

    Liu, Honghai; Ji, Xiaofei; Chan, Chee Seng; Khoury, Mehdi

    2017-01-01

    This book introduces readers to the latest exciting advances in human motion sensing and recognition, from the theoretical development of fuzzy approaches to their applications. The topics covered include human motion recognition in 2D and 3D, hand motion analysis with contact sensors, and vision-based view-invariant motion recognition, especially from the perspective of Fuzzy Qualitative techniques. With the rapid development of technologies in microelectronics, computers, networks, and robotics over the last decade, increasing attention has been focused on human motion sensing and recognition in many emerging and active disciplines where human motions need to be automatically tracked, analyzed or understood, such as smart surveillance, intelligent human-computer interaction, robot motion learning, and interactive gaming. Current challenges mainly stem from the dynamic environment, data multi-modality, uncertain sensory information, and real-time issues. These techniques are shown to effectively address the ...

  3. Measurement and Quantification of Gross Human Shoulder Motion

    Directory of Open Access Journals (Sweden)

    Jeremy T. Newkirk

    2013-01-01

    Full Text Available The shoulder girdle plays an important role in the large pointing workspace that humans enjoy. The goal of this work was to characterize the human shoulder girdle motion in relation to the arm. The overall motion of the human shoulder girdle was characterized based on motion studies completed on test subjects during voluntary (natural/unforced motion. The collected data from the experiments were used to develop surface fit equations that represent the position and orientation of the glenohumeral joint for a given humeral pointing direction. These equations completely quantify gross human shoulder girdle motion relative to the humerus. The equations are presented along with goodness-of-fit results that indicate the equations well approximate the motion of the human glenohumeral joint. This is the first time the motion has been quantified for the entire workspace, and the equations provide a reference against which to compare future work.

  4. Discriminative Vision-Based Recovery and Recognition of Human Motion

    NARCIS (Netherlands)

    Poppe, Ronald Walter

    2009-01-01

    The automatic analysis of human motion from images opens up the way for applications in the domains of security and surveillance, human-computer interaction, animation, retrieval and sports motion analysis. In this dissertation, the focus is on robust and fast human pose recovery and action

  5. Coupled motions in human and porcine thoracic and lumbar spines

    NARCIS (Netherlands)

    Kingma, Idsart; Busscher, Iris; van der Veen, Albert J.; Verkerke, Gijsbertus J.; Veldhuizen, Albert G.; Homminga, Jasper; van Dieën, Jaap H.

    2018-01-01

    Coupled motions, i.e., motions along axes other than the loaded axis, have been reported to occur in the human spine, and are likely to be influenced by inclined local axes due to the sagittal plane spine curvature. Furthermore, the role of facet joints in such motions is as yet unclear. Therefore,

  6. Coupled motions in human and porcine thoracic and lumbar spines

    NARCIS (Netherlands)

    Kingma, Idsart; Busscher, Iris; van der Veen, Albert J.; Verkerke, Gijsbertus J.; Veldhuizen, Albert G.; Homminga, Jasper; van Dieën, Jaap H.

    2017-01-01

    Coupled motions, i.e., motions along axes other than the loaded axis, have been reported to occur in the human spine, and are likely to be influenced by inclined local axes due to the sagittal plane spine curvature. Furthermore, the role of facet joints in such motions is as yet unclear. Therefore,

  7. Predicting articulated human motion from spatial processes

    DEFF Research Database (Denmark)

    Hauberg, Søren; Pedersen, Kim Steenstrup

    2011-01-01

    recent work where prior models are derived in terms of joint angles. This approach has several advantages. First of all, it allows us to construct motion models in low dimensional spaces, which makes motion estimation more robust. Secondly, as many types of motion are easily expressed in spatial...

  8. Human Motion Capture Data Tailored Transform Coding.

    Science.gov (United States)

    Junhui Hou; Lap-Pui Chau; Magnenat-Thalmann, Nadia; Ying He

    2015-07-01

    Human motion capture (mocap) is a widely used technique for digitalizing human movements. With growing usage, compressing mocap data has received increasing attention, since compact data size enables efficient storage and transmission. Our analysis shows that mocap data have some unique characteristics that distinguish themselves from images and videos. Therefore, directly borrowing image or video compression techniques, such as discrete cosine transform, does not work well. In this paper, we propose a novel mocap-tailored transform coding algorithm that takes advantage of these features. Our algorithm segments the input mocap sequences into clips, which are represented in 2D matrices. Then it computes a set of data-dependent orthogonal bases to transform the matrices to frequency domain, in which the transform coefficients have significantly less dependency. Finally, the compression is obtained by entropy coding of the quantized coefficients and the bases. Our method has low computational cost and can be easily extended to compress mocap databases. It also requires neither training nor complicated parameter setting. Experimental results demonstrate that the proposed scheme significantly outperforms state-of-the-art algorithms in terms of compression performance and speed.

  9. Reconstruction of malunited diaphyseal fractures of the forearm

    OpenAIRE

    Jayakumar, Prakash; Jupiter, Jesse B

    2014-01-01

    The forearm is a complex anatomical and functional unit with unique osseous, soft tissue and articular relationships. Disruption of these important relations can have a significant impact, leading to pain, instability of the radio-ulnar articulation and reduced range of motion. The gold standard for treating forearm fractures in adults remains anatomic reduction, stable plate fixation and preservation of the surrounding blood supply. Failure to achieve these goals may lead to malunion, requir...

  10. Automatic Video-based Analysis of Human Motion

    DEFF Research Database (Denmark)

    Fihl, Preben

    The human motion contains valuable information in many situations and people frequently perform an unconscious analysis of the motion of other people to understand their actions, intentions, and state of mind. An automatic analysis of human motion will facilitate many applications and thus has...... received great interest from both industry and research communities. The focus of this thesis is on video-based analysis of human motion and the thesis presents work within three overall topics, namely foreground segmentation, action recognition, and human pose estimation. Foreground segmentation is often...... the first important step in the analysis of human motion. By separating foreground from background the subsequent analysis can be focused and efficient. This thesis presents a robust background subtraction method that can be initialized with foreground objects in the scene and is capable of handling...

  11. Sybar, a human motion analysis system for rehabilition medicine

    NARCIS (Netherlands)

    Hautus, E.H.

    1997-01-01

    The Sybar project is a designer's Ph.D project that deals with the development of a motion-analysis system for rehabilitation medicine, at the VU Hospital in Amsterdam. Human motion can be analyzed by biomechanical measurement systems. There are a number of different methods to generate several

  12. Comparative potency of formulations of mometasone furoate in terms of inhibition of ′PIRHR′ in the forearm skin of normal human subjects measured with laser doppler velocimetry

    Directory of Open Access Journals (Sweden)

    Kulhalli Prabhakar

    2005-01-01

    Full Text Available BACKGROUND AND AIMS: Topical glucocorticoid formulations are widely used for effective treatment and control of a variety of dermatoses. Mometasone furoate is a newer corticoid that has high potency but low systemic toxicity. Pharmaceutical factors are known to significantly influence potency and systemic absorption of topically applied glucocorticoids. We studied the potency of "Elocon", a topical formulation of mometasone furoate, compared with two other branded formulations of the same corticoid. METHODS: Corticoid potency was measured by employing a pharmacodynamic parameter of an inhibitory effect of the corticoid on post-ischemic-reactive-hyperemic-response (PIRHR in human forearm skin under occlusive dressing. The PIRHR was expressed in terms of % increase in the skin blood flow (SBF as measured with laser doppler velocimetry (LDV. RESULTS : All three active branded formulations of mometasone furoate produced significant inhibition of PIRHR. The AUC(0-2min of PIRHR was ( Mean ± SEM , Control = 213.52 ± 11.80, Placebo = 209.77 ± 19.31, Formulation A = 119.83 ± 13.71, Formulation C = 53.67 ± 4.85 and Formulation D = 111.46 ± 22.87. Formulation "C" exhibited significantly higher topical anti-inflammatory potency than formulations "A" or "D". CONCLUSIONS: Thus, branded formulations of the same glucocorticoid, mometasone furoate significantly differed in their topical anti-inflammatory potency. "Elocon" was significantly more potent than the two other branded formulations studied.

  13. Interosseous Ligament and Transverse Forearm Stability: A Biomechanical Cadaver Study.

    Science.gov (United States)

    Gutowski, Christina J; Darvish, Kurosh; Ilyas, Asif M; Jones, Christopher M

    2017-02-01

    The interosseous ligament (IOL) is known to be an important longitudinal stabilizer of the forearm. We hypothesize that it may also contribute to transverse stability, with pronosupination tensioning of the radius relative to the ulna. Therefore, when injured, we predict the interosseous space should widen in the transverse plane, enough to be appreciable on plain radiographs. A measurable difference in interosseous space, comparing an injured with an uninjured forearm, can potentially be of diagnostic and clinical value. Ten fresh-frozen cadaver arms (from 5 individuals) were radiographed in 6 different positions of forearm supination, first in an uninjured state and then with the IOL sectioned, both partially (central band only) and completely. The transverse interosseous distance was measured on radiographs using edge detection software and compared using analysis of variance and contrast analysis. The maximum range of pronosupination was also compared before and after injury, using a paired t test. Average maximum supination increased from 84° to 106°, and pronation from 69° to 84°, after the IOL was sectioned completely. Sectioning of the IOL led to a statistically significant increase in the interosseous distance, a minimum of 2 mm, in all but one forearm position. The IOL of the forearm plays an important role in providing transverse stability to the radius and ulna. When the IOL is sectioned, the forearm exhibits increased pronosupination range of motion. Radiographs of bilateral forearms taken in identical rotational position can reliably differentiate between an intact and torn IOL in cadavers. The IOL's stabilizing role during forearm rotation suggests a novel strategy for diagnosing forearm IOL injury using comparative radiographic measurements. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  14. Hierarchical Aligned Cluster Analysis for Temporal Clustering of Human Motion.

    Science.gov (United States)

    Zhou, Feng; De la Torre, Fernando; Hodgins, Jessica K

    2013-03-01

    Temporal segmentation of human motion into plausible motion primitives is central to understanding and building computational models of human motion. Several issues contribute to the challenge of discovering motion primitives: the exponential nature of all possible movement combinations, the variability in the temporal scale of human actions, and the complexity of representing articulated motion. We pose the problem of learning motion primitives as one of temporal clustering, and derive an unsupervised hierarchical bottom-up framework called hierarchical aligned cluster analysis (HACA). HACA finds a partition of a given multidimensional time series into m disjoint segments such that each segment belongs to one of k clusters. HACA combines kernel k-means with the generalized dynamic time alignment kernel to cluster time series data. Moreover, it provides a natural framework to find a low-dimensional embedding for time series. HACA is efficiently optimized with a coordinate descent strategy and dynamic programming. Experimental results on motion capture and video data demonstrate the effectiveness of HACA for segmenting complex motions and as a visualization tool. We also compare the performance of HACA to state-of-the-art algorithms for temporal clustering on data of a honey bee dance. The HACA code is available online.

  15. Sensing human hand motions for controlling dexterous robots

    Science.gov (United States)

    Marcus, Beth A.; Churchill, Philip J.; Little, Arthur D.

    1988-01-01

    The Dexterous Hand Master (DHM) system is designed to control dexterous robot hands such as the UTAH/MIT and Stanford/JPL hands. It is the first commercially available device which makes it possible to accurately and confortably track the complex motion of the human finger joints. The DHM is adaptable to a wide variety of human hand sizes and shapes, throughout their full range of motion.

  16. Multi-level human motion analysis for surveillance applications

    NARCIS (Netherlands)

    Lao, W.; Han, Jungong; With, de P.H.N.; Rabbani, M.; Stevenson, R.L.

    2009-01-01

    In this paper, we study a flexible framework for semantic analysis of human motion from a monocular surveillance video. Successful trajectory estimation and human-body modeling facilitate the semantic analysis of human activities in video sequences. As a first contribution, we propose a flexible

  17. Microanatomical and immunohistochemical study of the human lateral antebrachial cutaneous nerve of forearm at the antecubital fossa and its clinical implications.

    Science.gov (United States)

    Marx, S Chakravarthy; Kumar, Pramod; Dhalapathy, S; Prasad, Keerthana; Marx, C Anitha

    2010-09-01

    Changes in the intraneural anatomy with age can cause poor prognosis of nerve repair in patients after nerve injury. The occurrence of Complex Regional Pain Syndrome-Type II, secondary to peripheral nerve injury, is common. The purpose of this study is to asses changes in cross-sectional anatomy of the lateral antebrachial cutaneous nerve of forearm (LCNF) at the antecubital fossa in the fascicular, nonfascicular components (adipose and nonadipose tissue), and sympathetic fibers area with respect to age. For the purpose of the study, 32 human (37-88 years) fresh cadaveric LCNF were collected from left-antecubital fossae and processed for histological, morphometric analysis [total cross-sectional (Asc), fascicular (Af), and nonfascicular area (Anonf)], and immunohistochemical method (tyrosine hydroxylase) for sympathetic fibers. The LCNF's average total cross-sectional area was 3.024 mm(2), and fascicular area was 0.582 mm(2). The average number of fascicles per mm(2) was 3.09. The cross-sectional area in the nerve was mainly occupied by nonfascicular connective tissue (80.75%). There was increased adipose tissue deposition (48.48% of Asc) and decreased collagen fibers (32.24% of Asc) in interfascicular domains without any definite relationship with age. The average sympathetic fiber area was 0.026 mm(2) within the nerve fascicular area without any correlation with age. In LCNF, there was more adipose tissue and less collagen fibers deposition in the interfascicular domains of all age cases, and this may act as an obstacle for nerve fiber regeneration on using LCNF as an interpositional nerve graft.

  18. Biodynamics of deformable human body motion

    Science.gov (United States)

    Strauss, A. M.; Huston, R. L.

    1976-01-01

    The objective is to construct a framework wherein the various models of human biomaterials fit in order to describe the biodynamic response of the human body. The behavior of the human body in various situations, from low frequency, low amplitude vibrations to impact loadings in automobile and aircraft crashes, is very complicated with respect to all aspects of the problem: materials, geometry and dynamics. The materials problem is the primary concern, but the materials problem is intimately connected with geometry and dynamics.

  19. Vision-based human motion analysis: An overview

    NARCIS (Netherlands)

    Poppe, Ronald Walter

    2007-01-01

    Markerless vision-based human motion analysis has the potential to provide an inexpensive, non-obtrusive solution for the estimation of body poses. The significant research effort in this domain has been motivated by the fact that many application areas, including surveillance, Human-Computer

  20. Human motion estimation with multiple frequency modulated continuous wave radars

    NARCIS (Netherlands)

    van Dorp, P.; Groen, F.C.A.

    2010-01-01

    Human motion estimation is an important issue in automotive, security or home automation applications. Radar systems are well suited for this because they are robust, are independent of day or night conditions and have accurate range and speed domain. The human response in a radar range-speed-time

  1. Serotonin-induced vasodilatation in the human forearm is mediated by the "nitric oxide-pathway": no evidence for involvement of the 5-HT3-receptor

    NARCIS (Netherlands)

    Bruning, T. A.; Chang, P. C.; Blauw, G. J.; Vermeij, P.; van Zwieten, P. A.

    1993-01-01

    The "nitric oxide (NO)-pathway" is presumed to be involved in acetylcholine (ACh)- and serotonin (5-hydroxytryptamine, 5-HT)-mediated vasodilatation. In addition, both the 5-HT-induced transient and persistent vasodilator responses in the forearm vascular bed are abolished by the

  2. Tissue oximetry: a comparison of mean values of regional tissue saturation, reproducibility and dynamic range of four NIRS-instruments on the human forearm

    DEFF Research Database (Denmark)

    Hyttel-Sørensen, Simon; Sorensen, Line C; Riera, Joan

    2011-01-01

    We compared absolute values of regional tissue hemoglobin saturation (StO(2)), reproducibility, and dynamic range of four different instruments on the forearm of adults. The sensors were repositioned 10 times on each subject. Dynamic range was estimated by exercise with subsequent arterial occlus...

  3. Effects of 5-hydroxytryptamine on capillary and arteriovenous anastomotic blood flow in the human hand and forearm and in the pig hind leg

    NARCIS (Netherlands)

    Blauw, G.; Bom, A. H.; van Brummelen, P.; Camps, J.; Arndt, J. W.; Verdouw, P. D.; Chang, P. C.; van Zwieten, P. A.; Saxena, P. R.

    1991-01-01

    The effects of intraarterially infused serotonin (5-HT) on capillary and arteriovenous anastomotic (AVA) blood flow were investigated in the hand and forearm of 19 healthy volunteers, and in the hind leg of six anesthetized pigs using radioactive microspheres with a diameter of 15 microns. The

  4. An adaptive approach to human motion tracking from video

    Science.gov (United States)

    Wu, Lifang; Chen, Chang Wen

    2010-07-01

    Vision based human motion tracking has drawn considerable interests recently because of its extensive applications. In this paper, we propose an approach to tracking the body motion of human balancing on each foot. The ability to balance properly is an important indication of neurological condition. Comparing with many other human motion tracking, there is much less occlusion in human balancing tracking. This less constrained problem allows us to combine a 2D model of human body with image analysis techniques to develop an efficient motion tracking algorithm. First we define a hierarchical 2D model consisting of six components including head, body and four limbs. Each of the four limbs involves primary component (upper arms and legs) and secondary component (lower arms and legs) respectively. In this model, we assume each of the components can be represented by quadrangles and every component is connected to one of others by a joint. By making use of inherent correlation between different components, we design a top-down updating framework and an adaptive algorithm with constraints of foreground regions for robust and efficient tracking. The approach has been tested using the balancing movement in HumanEva-I/II dataset. The average tracking time is under one second, which is much shorter than most of current schemes.

  5. Visual gravitational motion and the vestibular system in humans

    Directory of Open Access Journals (Sweden)

    Francesco eLacquaniti

    2013-12-01

    Full Text Available The visual system is poorly sensitive to arbitrary accelerations, but accurately detects the effects of gravity on a target motion. Here we review behavioral and neuroimaging data about the neural mechanisms for dealing with object motion and egomotion under gravity. The results from several experiments show that the visual estimates of a target motion under gravity depend on the combination of a prior of gravity effects with on-line visual signals on target position and velocity. These estimates are affected by vestibular inputs, and are encoded in a visual-vestibular network whose core regions lie within or around the Sylvian fissure, and are represented by the posterior insula/retroinsula/temporo-parietal junction. This network responds both to target motions coherent with gravity and to vestibular caloric stimulation in human fMRI studies. Transient inactivation of the temporo-parietal junction selectively disrupts the interception of targets accelerated by gravity.

  6. Visual gravitational motion and the vestibular system in humans.

    Science.gov (United States)

    Lacquaniti, Francesco; Bosco, Gianfranco; Indovina, Iole; La Scaleia, Barbara; Maffei, Vincenzo; Moscatelli, Alessandro; Zago, Myrka

    2013-12-26

    The visual system is poorly sensitive to arbitrary accelerations, but accurately detects the effects of gravity on a target motion. Here we review behavioral and neuroimaging data about the neural mechanisms for dealing with object motion and egomotion under gravity. The results from several experiments show that the visual estimates of a target motion under gravity depend on the combination of a prior of gravity effects with on-line visual signals on target position and velocity. These estimates are affected by vestibular inputs, and are encoded in a visual-vestibular network whose core regions lie within or around the Sylvian fissure, and are represented by the posterior insula/retroinsula/temporo-parietal junction. This network responds both to target motions coherent with gravity and to vestibular caloric stimulation in human fMRI studies. Transient inactivation of the temporo-parietal junction selectively disrupts the interception of targets accelerated by gravity.

  7. Anatomy and biomechanics of the forearm interosseous membrane.

    Science.gov (United States)

    Farr, Leela D; Werner, Frederick W; McGrattan, Michael L; Zwerling, Sierra R; Harley, Brian J

    2015-06-01

    To examine the anatomy and function of the forearm interosseous membrane by exploring the anatomical insertions of the central band (CB) on the radius and the ulna and by quantifying the length of the intact ligament and replacement grafts located at the original CB attachment sites and alternative locations. Eight fresh cadaver forearms were supinated and pronated and the wrist was extended and flexed while the motion between the distal radius and ulna were recorded. The length of the CB was computed for the intact CB as well for several alternative graft orientations and positions. The maximum length of the CB did not significantly change among different wrist motions. However, with the wrist in a static neutral position, the CB length was significantly shorter in forearm supination than in neutral. During active forearm rotation when CB replacement grafts were positioned distal or proximal to the original CB site, yet still parallel to it, each had a similar trend to be longer in neutral than in supination. If a graft was more transversely oriented, the computed CB length would be 1.6 mm shorter in supination than in neutral. These results support tensioning a CB graft with the forearm in supination if the goal is to maximize graft tension and to maintain the native 22° angle for a CB graft between the radius and ulna. The results also suggest that the CB graft can probably be located slightly distal or slightly proximal to its original attachment sites. Reconstruction of the interosseous membrane has been hampered by a lack of understanding of its length changes with forearm or wrist motion. These results provide a starting point in helping clinicians understand how to more precisely reconstruct this ligament in an anatomical manner. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  8. A Self-Powered Insole for Human Motion Recognition

    Directory of Open Access Journals (Sweden)

    Yingzhou Han

    2016-09-01

    Full Text Available Biomechanical energy harvesting is a feasible solution for powering wearable sensors by directly driving electronics or acting as wearable self-powered sensors. A wearable insole that not only can harvest energy from foot pressure during walking but also can serve as a self-powered human motion recognition sensor is reported. The insole is designed as a sandwich structure consisting of two wavy silica gel film separated by a flexible piezoelectric foil stave, which has higher performance compared with conventional piezoelectric harvesters with cantilever structure. The energy harvesting insole is capable of driving some common electronics by scavenging energy from human walking. Moreover, it can be used to recognize human motion as the waveforms it generates change when people are in different locomotion modes. It is demonstrated that different types of human motion such as walking and running are clearly classified by the insole without any external power source. This work not only expands the applications of piezoelectric energy harvesters for wearable power supplies and self-powered sensors, but also provides possible approaches for wearable self-powered human motion monitoring that is of great importance in many fields such as rehabilitation and sports science.

  9. Using Human Motion Intensity as Input for Urban Design

    DEFF Research Database (Denmark)

    Poulsen, Esben Skouboe; Andersen, Hans Jørgen; Gade, Rikke

    2012-01-01

    of a town square, human occupancy and motion intensities are used to generate situated or topologies presenting new adaptive methods for urban design. These methods incorporate local or as design drivers for canopy, pavement and furniture layout. The urban design solution may be congured due to various...

  10. Coupled motions direct electrons along human microsomal P450 Chains.

    Directory of Open Access Journals (Sweden)

    Christopher R Pudney

    2011-12-01

    Full Text Available Protein domain motion is often implicated in biological electron transfer, but the general significance of motion is not clear. Motion has been implicated in the transfer of electrons from human cytochrome P450 reductase (CPR to all microsomal cytochrome P450s (CYPs. Our hypothesis is that tight coupling of motion with enzyme chemistry can signal "ready and waiting" states for electron transfer from CPR to downstream CYPs and support vectorial electron transfer across complex redox chains. We developed a novel approach to study the time-dependence of dynamical change during catalysis that reports on the changing conformational states of CPR. FRET was linked to stopped-flow studies of electron transfer in CPR that contains donor-acceptor fluorophores on the enzyme surface. Open and closed states of CPR were correlated with key steps in the catalytic cycle which demonstrated how redox chemistry and NADPH binding drive successive opening and closing of the enzyme. Specifically, we provide evidence that reduction of the flavin moieties in CPR induces CPR opening, whereas ligand binding induces CPR closing. A dynamic reaction cycle was created in which CPR optimizes internal electron transfer between flavin cofactors by adopting closed states and signals "ready and waiting" conformations to partner CYP enzymes by adopting more open states. This complex, temporal control of enzyme motion is used to catalyze directional electron transfer from NADPH→FAD→FMN→heme, thereby facilitating all microsomal P450-catalysed reactions. Motions critical to the broader biological functions of CPR are tightly coupled to enzyme chemistry in the human NADPH-CPR-CYP redox chain. That redox chemistry alone is sufficient to drive functionally necessary, large-scale conformational change is remarkable. Rather than relying on stochastic conformational sampling, our study highlights a need for tight coupling of motion to enzyme chemistry to give vectorial electron

  11. Interactions of mean body and local skin temperatures in the modulation of human forearm and calf blood flows: a three-dimensional description.

    Science.gov (United States)

    Caldwell, Joanne N; Matsuda-Nakamura, Mayumi; Taylor, Nigel A S

    2016-02-01

    The inter-relationships between mean body and local skin temperatures have previously been established for controlling hand and foot blood flows. Since glabrous skin contains many arteriovenous anastomoses, it was important to repeat those experiments on non-glabrous regions using the same sample and experimental conditions. Mild hypothermia (mean body temperature 31.4 °C), normothermia (control: 36.0 °C) and moderate hyperthermia (38.3 °C) were induced and clamped (climate chamber and water-perfusion garment) in eight males. Within each condition, five localised thermal treatments (5, 15, 25, 33, 40 °C) were applied to the left forearm and right calf. Steady-state forearm and calf blood flows were measured (venous occlusion plethysmography) for each of the resulting 15 combinations of clamped mean body and local skin temperatures. Under the normothermic clamp, cutaneous blood flows averaged 4.2 mL 100 mL(-1) min(-1) (±0.28: forearm) and 5.4 mL 100 mL(-1) min(-1) (±0.27: calf). When mildly hypothermic, these segments were unresponsive to localised thermal stimuli, but tracked those changes when normothermic and moderately hyperthermic. For deep-body (oesophageal) temperature elevations, forearm blood flow increased by 5.1 mL 100 mL(-1) min(-1) °C(-1) (±0.9) relative to normothermia, while the calf was much less responsive: 3.3 mL 100 mL(-1) min(-1) °C(-1) (±1.5). Three-dimensional surfaces revealed a qualitative divergence in the control of calf blood flow, with vasoconstrictor tone apparently being released more gradually. These descriptions reinforce the importance of deep-tissue temperatures in controlling cutaneous perfusion, with this modulation being non-linear at the forearm and appearing linear for the calf.

  12. Human motion behavior while interacting with an industrial robot.

    Science.gov (United States)

    Bortot, Dino; Ding, Hao; Antonopolous, Alexandros; Bengler, Klaus

    2012-01-01

    Human workers and industrial robots both have specific strengths within industrial production. Advantageously they complement each other perfectly, which leads to the development of human-robot interaction (HRI) applications. Bringing humans and robots together in the same workspace may lead to potential collisions. The avoidance of such is a central safety requirement. It can be realized with sundry sensor systems, all of them decelerating the robot when the distance to the human decreases alarmingly and applying the emergency stop, when the distance becomes too small. As a consequence, the efficiency of the overall systems suffers, because the robot has high idle times. Optimized path planning algorithms have to be developed to avoid that. The following study investigates human motion behavior in the proximity of an industrial robot. Three different kinds of encounters between the two entities under three robot speed levels are prompted. A motion tracking system is used to capture the motions. Results show, that humans keep an average distance of about 0,5m to the robot, when the encounter occurs. Approximation of the workbenches is influenced by the robot in ten of 15 cases. Furthermore, an increase of participants' walking velocity with higher robot velocities is observed.

  13. Time-frequency analysis of human motion during rhythmic exercises.

    Science.gov (United States)

    Omkar, S N; Vyas, Khushi; Vikranth, H N

    2011-01-01

    Biomechanical signals due to human movements during exercise are represented in time-frequency domain using Wigner Distribution Function (WDF). Analysis based on WDF reveals instantaneous spectral and power changes during a rhythmic exercise. Investigations were carried out on 11 healthy subjects who performed 5 cycles of sun salutation, with a body-mounted Inertial Measurement Unit (IMU) as a motion sensor. Variance of Instantaneous Frequency (I.F) and Instantaneous Power (I.P) for performance analysis of the subject is estimated using one-way ANOVA model. Results reveal that joint Time-Frequency analysis of biomechanical signals during motion facilitates a better understanding of grace and consistency during rhythmic exercise.

  14. Optical Myography: Detecting Finger Movements by Looking at the Forearm

    Directory of Open Access Journals (Sweden)

    Christian eNissler

    2016-04-01

    Full Text Available One of the crucial problems found in the scientific community of assistive / rehabilitation robotics nowadays is that of automatically detecting what a disabled subject (for instance, a hand amputee wants to do, exactly when she wants to do it and strictly for the time she wants to do it. This problem, commonly called intent detection, has traditionally been tackled using surface electromyography, a technique which suffers from a number of drawbacks, including the changes in the signal induced by sweat and muscle fatigue. With the advent of realistic, physically plausible augmented- and virtual-reality environments for rehabilitation, this approach does not suffice anymore. In this paper we explore a novel method to solve the problem, that we call Optical Myography (OMG. The idea is to visually inspect the human forearm (or stump to reconstruct what fingers are moving and to what extent. In a psychophysical experiment involving ten intact subjects, we used visual fiducial markers (AprilTags and a standard web-camera to visualize the deformations of the surface of the forearm, which then were mapped to the intended finger motions. As ground truth, a visual stimulus was used, avoiding the need for finger sensors (force/position sensors, datagloves, etc.. Two machine-learning approaches, a linear and a non-linear one, were comparatively tested in settings of increasing realism. The results indicate an average error in the range of 0.05 to 0.22 (root mean square error normalized over the signal range, in line with similar results obtained with more mature techniques such as electromyography. If further successfully tested in the large, this approach could lead to vision-based intent detection of amputees, with the main application of letting such disabled persons dexterously and reliably interact in an augmented- / virtual-reality setup.

  15. Representation of visual gravitational motion in the human vestibular cortex.

    Science.gov (United States)

    Indovina, Iole; Maffei, Vincenzo; Bosco, Gianfranco; Zago, Myrka; Macaluso, Emiliano; Lacquaniti, Francesco

    2005-04-15

    How do we perceive the visual motion of objects that are accelerated by gravity? We propose that, because vision is poorly sensitive to accelerations, an internal model that calculates the effects of gravity is derived from graviceptive information, is stored in the vestibular cortex, and is activated by visual motion that appears to be coherent with natural gravity. The acceleration of visual targets was manipulated while brain activity was measured using functional magnetic resonance imaging. In agreement with the internal model hypothesis, we found that the vestibular network was selectively engaged when acceleration was consistent with natural gravity. These findings demonstrate that predictive mechanisms of physical laws of motion are represented in the human brain.

  16. New human-centered linear and nonlinear motion cueing algorithms for control of simulator motion systems

    Science.gov (United States)

    Telban, Robert J.

    While the performance of flight simulator motion system hardware has advanced substantially, the development of the motion cueing algorithm, the software that transforms simulated aircraft dynamics into realizable motion commands, has not kept pace. To address this, new human-centered motion cueing algorithms were developed. A revised "optimal algorithm" uses time-invariant filters developed by optimal control, incorporating human vestibular system models. The "nonlinear algorithm" is a novel approach that is also formulated by optimal control, but can also be updated in real time. It incorporates a new integrated visual-vestibular perception model that includes both visual and vestibular sensation and the interaction between the stimuli. A time-varying control law requires the matrix Riccati equation to be solved in real time by a neurocomputing approach. Preliminary pilot testing resulted in the optimal algorithm incorporating a new otolith model, producing improved motion cues. The nonlinear algorithm vertical mode produced a motion cue with a time-varying washout, sustaining small cues for longer durations and washing out large cues more quickly compared to the optimal algorithm. The inclusion of the integrated perception model improved the responses to longitudinal and lateral cues. False cues observed with the NASA adaptive algorithm were absent. As a result of unsatisfactory sensation, an augmented turbulence cue was added to the vertical mode for both the optimal and nonlinear algorithms. The relative effectiveness of the algorithms, in simulating aircraft maneuvers, was assessed with an eleven-subject piloted performance test conducted on the NASA Langley Visual Motion Simulator (VMS). Two methods, the quasi-objective NASA Task Load Index (TLX), and power spectral density analysis of pilot control, were used to assess pilot workload. TLX analysis reveals, in most cases, less workload and variation among pilots with the nonlinear algorithm. Control input

  17. Human detection and motion analysis at security points

    Science.gov (United States)

    Ozer, I. Burak; Lv, Tiehan; Wolf, Wayne H.

    2003-08-01

    This paper presents a real-time video surveillance system for the recognition of specific human activities. Specifically, the proposed automatic motion analysis is used as an on-line alarm system to detect abnormal situations in a campus environment. A smart multi-camera system developed at Princeton University is extended for use in smart environments in which the camera detects the presence of multiple persons as well as their gestures and their interaction in real-time.

  18. Wearable sensor system for human localization and motion capture

    OpenAIRE

    Zihajehzadeh, Shaghayegh

    2017-01-01

    Recent advances in MEMS wearable inertial/magnetic sensors and mobile computing have fostered a dramatic growth of interest for ambulatory human motion capture (MoCap). Compared to traditional optical MoCap systems such as the optical systems, inertial (i.e. accelerometer and gyroscope) and magnetic sensors do not require external fixtures such as cameras. Hence, they do not have in-the-lab measurement limitations and thus are ideal for ambulatory applications. However, due to the manufacturi...

  19. X-Ray Exam: Forearm

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Forearm KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  20. Energy Optimal Trajectories in Human Arm Motion Aiming for Assistive Robots

    Directory of Open Access Journals (Sweden)

    Lelai Zhou

    2017-01-01

    Full Text Available The energy expenditure in human arm has been of great interests for seeking optimal human arm trajectories. This paper presents a new way for calculating metabolic energy consumption of human arm motions. The purpose is to reveal the relationship between the energy consumption and the trajectory of arm motion, and further, the acceleration and arm orientation contributions. Human arm motion in horizontal plane is investigated by virtue of Qualisys motion capture system. The motion data is post-processed by a biomechanical model to obtain the metabolic expenditure. Results on the arm motion kinematics, dynamics and metabolic energy consumption, are included.

  1. Non-invasive techniques for the measurement of extraction fraction and permeability surface area product of 99Tcm DTPA in the human forearm

    International Nuclear Information System (INIS)

    Bell, S.D.; Peters, A.M.; Myers, M.J.

    1992-01-01

    Only a very limited number of clinical studies have been reported on the measurement of endothelial permeability to hydrophilic solutes (molecular weight 99 Tc m DTPA, are perfusion-dependent as well as diffusion-dependent. The authors describe non-invasive techniques for measurement of clearance and extraction fraction of 99 Tc m DTPA into the extravascular space of the resting forearm using a scintillation probe, from which we then calculated permeability surface area (PS) product. Their values for extraction fraction of about 0.5 and for PS product of about 3 ml per minute per 100 ml tissue are comparable to values reported in the literature for resting skeletal muscle using more invasive techniques. (author)

  2. The Community Orthopaedic Surgeon Taking Trauma Call: Pediatric Forearm Shaft Fracture Pearls and Pitfalls.

    Science.gov (United States)

    Herman, Martin J; Simon, Matthew; Mehlman, Charles T

    2017-11-01

    Pediatric forearm shaft fractures are the third most common fracture in children, and the forearm is the third most mobile joint in the body (with a nearly 180 degree arc of motion). The goals of treatment are aimed squarely at achieving satisfactory anatomic alignment (within defined parameters) as the consequences of malunion can be permanent forearm stiffness and deformity. Nonoperative treatment approaches still dominate care of the youngest age groups while surgical intervention has become increasingly common in older children. This article will offer evidence and experience-based tips intended to benefit the community orthopedic surgeon caring for children during the course of their on-call duties.

  3. Camera systems in human motion analysis for biomedical applications

    Science.gov (United States)

    Chin, Lim Chee; Basah, Shafriza Nisha; Yaacob, Sazali; Juan, Yeap Ewe; Kadir, Aida Khairunnisaa Ab.

    2015-05-01

    Human Motion Analysis (HMA) system has been one of the major interests among researchers in the field of computer vision, artificial intelligence and biomedical engineering and sciences. This is due to its wide and promising biomedical applications, namely, bio-instrumentation for human computer interfacing and surveillance system for monitoring human behaviour as well as analysis of biomedical signal and image processing for diagnosis and rehabilitation applications. This paper provides an extensive review of the camera system of HMA, its taxonomy, including camera types, camera calibration and camera configuration. The review focused on evaluating the camera system consideration of the HMA system specifically for biomedical applications. This review is important as it provides guidelines and recommendation for researchers and practitioners in selecting a camera system of the HMA system for biomedical applications.

  4. Simultaneous estimation of human and exoskeleton motion: A simplified protocol.

    Science.gov (United States)

    Alvarez, M T; Torricelli, D; Del-Ama, A J; Pinto, D; Gonzalez-Vargas, J; Moreno, J C; Gil-Agudo, A; Pons, J L

    2017-07-01

    Adequate benchmarking procedures in the area of wearable robots is gaining importance in order to compare different devices on a quantitative basis, improve them and support the standardization and regulation procedures. Performance assessment usually focuses on the execution of locomotion tasks, and is mostly based on kinematic-related measures. Typical drawbacks of marker-based motion capture systems, gold standard for measure of human limb motion, become challenging when measuring limb kinematics, due to the concomitant presence of the robot. This work answers the question of how to reliably assess the subject's body motion by placing markers over the exoskeleton. Focusing on the ankle joint, the proposed methodology showed that it is possible to reconstruct the trajectory of the subject's joint by placing markers on the exoskeleton, although foot flexibility during walking can impact the reconstruction accuracy. More experiments are needed to confirm this hypothesis, and more subjects and walking conditions are needed to better characterize the errors of the proposed methodology, although our results are promising, indicating small errors.

  5. Adaptive Human aware Navigation based on Motion Pattern Analysis

    DEFF Research Database (Denmark)

    Tranberg, Søren; Svenstrup, Mikael; Andersen, Hans Jørgen

    2009-01-01

    Respecting people’s social spaces is an important prerequisite for acceptable and natural robot navigation in human environments. In this paper, we describe an adaptive system for mobile robot navigation based on estimates of whether a person seeks to interact with the robot or not. The estimates...... are based on run-time motion pattern analysis compared to stored experience in a database. Using a potential field centered around the person, the robot positions itself at the most appropriate place relative to the person and the interaction status. The system is validated through qualitative tests...

  6. Computer simulation of human motion in sports biomechanics.

    Science.gov (United States)

    Vaughan, C L

    1984-01-01

    This chapter has covered some important aspects of the computer simulation of human motion in sports biomechanics. First the definition and the advantages and limitations of computer simulation were discussed; second, research on various sporting activities were reviewed. These activities included basic movements, aquatic sports, track and field athletics, winter sports, gymnastics, and striking sports. This list was not exhaustive and certain material has, of necessity, been omitted. However, it was felt that a sufficiently broad and interesting range of activities was chosen to illustrate both the advantages and the pitfalls of simulation. It is almost a decade since Miller [53] wrote a review chapter similar to this one. One might be tempted to say that things have changed radically since then--that computer simulation is now a widely accepted and readily applied research tool in sports biomechanics. This is simply not true, however. Biomechanics researchers still tend to emphasize the descriptive type of study, often unfortunately, when a little theoretical explanation would have been more helpful [29]. What will the next decade bring? Of one thing we can be certain: The power of computers, particularly the readily accessible and portable microcomputer, will expand beyond all recognition. The memory and storage capacities will increase dramatically on the hardware side, and on the software side the trend will be toward "user-friendliness." It is likely that a number of software simulation packages designed specifically for studying human motion [31, 96] will be extensively tested and could gain wide acceptance in the biomechanics research community. Nevertheless, a familiarity with Newtonian and Lagrangian mechanics, optimization theory, and computers in general, as well as practical biomechanical insight, will still be a prerequisite for successful simulation models of human motion. Above all, the biomechanics researcher will still have to bear in mind that

  7. Measurement of forearm oxygen consumption

    DEFF Research Database (Denmark)

    Astrup, A; Simonsen, L; Bülow, J

    1988-01-01

    The classical forearm technique widely used for studies of skeletal muscle metabolism requires arterial cannulation. To avoid arterial puncture it is becoming more common to arterialize blood from a contralateral hand vein by local heating. This modification and the classical method have produced...... blood flow and decreases skeletal muscle blood flow. This facilitates mixing of superficial blood with deep venous blood. Contralateral heating increased deep venous oxygen saturation and abolished the pronounced glucose-induced increase in oxygen consumption observed in the control experiments after...... contradictory results regarding the contribution of skeletal muscle to glucose-induced thermogenesis. The effect on forearm circulation and the metabolism of heating the contralateral hand was examined before and after an oral glucose load. The results suggest that contralateral heating increases subcutaneous...

  8. Case report: accessory head of the deep forearm flexors

    Science.gov (United States)

    JONES, M.; ABRAHAMS, P. H.; SAÑUDO, J. R.

    1997-01-01

    In 1813 Gantzer described 2 accessory muscles in the human forearm which bear his name (Wood, 1868; Macalister, 1875) and these have subsequently been reported with variable attachments (Wood, 1868; Macalister, 1875; Turner, 1879; Schäfer & Thane, 1894; Le Double, 1897; Dykes & Anson, 1944; Mangini, 1960; Malhotra et al. 1982; Kida, 1988; Tountas & Bergman, 1993). The accessory heads of the deep flexors of the forearm (Gantzer's muscles) have been described as 2 different small bellies which insert either into FPL or FDP. There are no previous reports which have mentioned the existence of an accessory muscle which inserts into both of the 2 deep flexors of the forearm as in the case presented here. PMID:9306208

  9. Digital anthropomorphic phantoms of non-rigid human respiratory and voluntary body motion for investigating motion correction in emission imaging

    International Nuclear Information System (INIS)

    Könik, Arda; Johnson, Karen L; Dasari, Paul; Pretorius, P H; Dey, Joyoni; King, Michael A; Connolly, Caitlin M; Segars, Paul W; Lindsay, Clifford

    2014-01-01

    The development of methods for correcting patient motion in emission tomography has been receiving increased attention. Often the performance of these methods is evaluated through simulations using digital anthropomorphic phantoms, such as the commonly used extended cardiac torso (XCAT) phantom, which models both respiratory and cardiac motion based on human studies. However, non-rigid body motion, which is frequently seen in clinical studies, is not present in the standard XCAT phantom. In addition, respiratory motion in the standard phantom is limited to a single generic trend. In this work, to obtain a more realistic representation of motion, we developed a series of individual-specific XCAT phantoms, modeling non-rigid respiratory and non-rigid body motions derived from the magnetic resonance imaging (MRI) acquisitions of volunteers. Acquisitions were performed in the sagittal orientation using the Navigator methodology. Baseline (no motion) acquisitions at end-expiration were obtained at the beginning of each imaging session for each volunteer. For the body motion studies, MRI was again acquired only at end-expiration for five body motion poses (shoulder stretch, shoulder twist, lateral bend, side roll, and axial slide). For the respiratory motion studies, an MRI was acquired during free/regular breathing. The magnetic resonance slices were then retrospectively sorted into 14 amplitude-binned respiratory states, end-expiration, end-inspiration, six intermediary states during inspiration, and six during expiration using the recorded Navigator signal. XCAT phantoms were then generated based on these MRI data by interactive alignment of the organ contours of the XCAT with the MRI slices using a graphical user interface. Thus far we have created five body motion and five respiratory motion XCAT phantoms from the MRI acquisitions of six healthy volunteers (three males and three females). Non-rigid motion exhibited by the volunteers was reflected in both respiratory

  10. Digital anthropomorphic phantoms of non-rigid human respiratory and voluntary body motion for investigating motion correction in emission imaging

    Science.gov (United States)

    Könik, Arda; Connolly, Caitlin M.; Johnson, Karen L.; Dasari, Paul; Segars, Paul W.; Pretorius, P. H.; Lindsay, Clifford; Dey, Joyoni; King, Michael A.

    2014-07-01

    The development of methods for correcting patient motion in emission tomography has been receiving increased attention. Often the performance of these methods is evaluated through simulations using digital anthropomorphic phantoms, such as the commonly used extended cardiac torso (XCAT) phantom, which models both respiratory and cardiac motion based on human studies. However, non-rigid body motion, which is frequently seen in clinical studies, is not present in the standard XCAT phantom. In addition, respiratory motion in the standard phantom is limited to a single generic trend. In this work, to obtain a more realistic representation of motion, we developed a series of individual-specific XCAT phantoms, modeling non-rigid respiratory and non-rigid body motions derived from the magnetic resonance imaging (MRI) acquisitions of volunteers. Acquisitions were performed in the sagittal orientation using the Navigator methodology. Baseline (no motion) acquisitions at end-expiration were obtained at the beginning of each imaging session for each volunteer. For the body motion studies, MRI was again acquired only at end-expiration for five body motion poses (shoulder stretch, shoulder twist, lateral bend, side roll, and axial slide). For the respiratory motion studies, an MRI was acquired during free/regular breathing. The magnetic resonance slices were then retrospectively sorted into 14 amplitude-binned respiratory states, end-expiration, end-inspiration, six intermediary states during inspiration, and six during expiration using the recorded Navigator signal. XCAT phantoms were then generated based on these MRI data by interactive alignment of the organ contours of the XCAT with the MRI slices using a graphical user interface. Thus far we have created five body motion and five respiratory motion XCAT phantoms from the MRI acquisitions of six healthy volunteers (three males and three females). Non-rigid motion exhibited by the volunteers was reflected in both respiratory

  11. Contralateral tactile masking between forearms.

    Science.gov (United States)

    D'Amour, Sarah; Harris, Laurence R

    2014-03-01

    Masking effects have been demonstrated in which tactile sensitivity is affected when one touch is close to another on the body surface. Such effects are likely a result of local lateral inhibitory circuits that sharpen the spatial tuning of a given tactile receptor. Mutually inhibitory pathways have also been demonstrated between cortical tactile maps of the two halves of the body. Occasional reports have indicated that touches on one hand or forearm can affect tactile sensitivity at contralateral locations. Here, we measure the spatial tuning and effect of posture on this contralateral masking effect. Tactile sensitivity was measured on one forearm, while vibrotactile masking stimulation was applied to the opposite arm. Results were compared to sensitivity while vibrotactile stimulation was applied to a control site on the right shoulder. Sensitivity on the forearm was reduced by over 3 dB when the arms were touching and by 0.52 dB when they were held parallel. The masking effect depended on the position of the masking stimulus. Its effectiveness fell off by 1 STD when the stimulus was 29 % of arm length from the corresponding contralateral point. This long-range inhibitory effect in the tactile system suggests a surprisingly intimate relationship between the two sides of the body.

  12. Adding Image Constraints to Inverse Kinematics for Human Motion Capture

    Science.gov (United States)

    Jaume-i-Capó, Antoni; Varona, Javier; González-Hidalgo, Manuel; Perales, Francisco J.

    2009-12-01

    In order to study human motion in biomechanical applications, a critical component is to accurately obtain the 3D joint positions of the user's body. Computer vision and inverse kinematics are used to achieve this objective without markers or special devices attached to the body. The problem of these systems is that the inverse kinematics is "blinded" with respect to the projection of body segments into the images used by the computer vision algorithms. In this paper, we present how to add image constraints to inverse kinematics in order to estimate human motion. Specifically, we explain how to define a criterion to use images in order to guide the posture reconstruction of the articulated chain. Tests with synthetic images show how the scheme performs well in an ideal situation. In order to test its potential in real situations, more experiments with task specific image sequences are also presented. By means of a quantitative study of different sequences, the results obtained show how this approach improves the performance of inverse kinematics in this application.

  13. Open Fracture of the Forearm Bones due to Horse Bite

    Directory of Open Access Journals (Sweden)

    John Ashutosh Santoshi

    2014-01-01

    Full Text Available Introduction: Fractures have been described mainly following falling accidents in horse-related injuries. Horse bites are uncommon accidents. We present a case of open fracture of the forearm due to horse bite. Case Report: A 35-year-old male farm-worker presented to the emergency room with alleged history of horse bite to the right forearm about 2 hours prior to presentation while feeding the horse. There was deformity of the forearm with multiple puncture wounds, deep abrasions and small lacerations on the distal-third of the forearm. Copious irrigation with normal saline was done and he was administered anti-tetanus and post-exposure rabies prophylaxis. Prophylactic antibiotic therapy was commenced. Radiographs revealed fracture of radius and ulna in the mid-shaft region. He underwent emergency wound debridement, and the ulna was stabilised with an intra-medullary square nail. Seventy-two hours later, he underwent re-debridement and conversion osteosynthesis. He had an uneventful recovery and at three-month follow-up, the fractures had healed radiographically in anatomic alignment. At two-year follow-up, he is doing well, is pain free and has a normal range of motion compared to the contralateral side. Conclusion: Horse bites behave as compound fractures however rabies prophylaxis will be needed and careful observation is needed. Early radical debridement, preliminary skeletal stabilisation, re-debridement and conversion osteosynthesis to plate, and antibiotic prophylaxis were the key to the successful management of our patient. Keywords: Horse; animal bite; forearm; open fracture

  14. The oblique cord of the forearm in man.

    Science.gov (United States)

    Tubbs, R Shane; O'Neil, James T; Key, Christopher D; Zarzour, Jessica G; Fulghum, Sarah B; Kim, Eugenia J; Lyerly, Michael J; Shoja, Mohammadali M; George Salter, E; Jerry Oakes, W

    2007-05-01

    There is minimal and often conflicting data in the literature regarding the oblique cord of the forearm. The current study seeks to elucidate further the anatomy of this structure of the upper extremity. In adult cadavers, the oblique cord was observed for and, when found, measurements were made of it. Ranges of motion were carried out while observation of the oblique cord was made. An oblique cord was found on 52.6% of sides. Gantzer's muscle was found on 55% of sides and, when present, had attachment into the oblique cord on five sides. The oblique cord was present on 13 sides with a Gantzer's muscle. Of the 20 sides with an oblique cord, no Gantzer's muscle was found on 10. The mean length of the oblique cord was 3.4 cm. In the majority of specimens, this cord tapered from proximal to distal. The proximal, middle, and distal widths of this structure had means 9, 7, and 4 mm, respectively. The oblique cord was found to travel approximately 45 degrees from a line drawn through the ulna and more or less traveled perpendicular to the insertion site of the bicipital tendon. This ligament was lax in the neutral position and with pronation became lax in all specimens. The oblique cord progressively became taut with increased supination from the neutral position and was maximally taut with the forearm fully supinated. Tautness of this cord was also found with distal distraction of the radius. Following the transection of the oblique cord, no discernable difference was observed in regard to maximal supination of the forearm or distal distraction of the radius. No obvious instability of the proximal forearm was found following transection of the oblique cord. Functionally, although the oblique cord may resist supination, it is unlikely that this structure affords significant stability to the proximal forearm, as it was often absent, of a very small caliber, and based on our observations, following its transection, the amount of supination of the forearm did not increase

  15. Electrical Properties of PPy-Coated Conductive Fabrics for Human Joint Motion Monitoring

    Directory of Open Access Journals (Sweden)

    Jiyong Hu

    2016-03-01

    Full Text Available Body motion signals indicate several pathological features of the human body, and a wearable human motion monitoring system can respond to human joint motion signal in real time, thereby enabling the prevention and treatment of some diseases. Because conductive fabrics can be well integrated with the garment, they are ideal as a sensing element of wearable human motion monitoring systems. This study prepared polypyrrole conductive fabric by in situ polymerization, and the anisotropic property of the conductive fabric resistance, resistance–strain relationship, and the relationship between resistance and the human knee and elbow movements are discussed preliminarily.

  16. The functional anatomy of forearm rotation

    OpenAIRE

    Lees, Vivien C.

    2009-01-01

    The elbow, forearm and wrist act as a unified structure to provide a stable, strong and highly mobile strut for positioning the hand in space and for conducting load-bearing tasks. An understanding of the relevant anatomy and biomechanics is important for the surgeon assessing and treating disorders of forearm function. This paper is concerned with illuminating the principles and concepts governing forearm rotation and load-bearing functions.

  17. Energy harvesting from human motion: exploiting swing and shock excitations

    International Nuclear Information System (INIS)

    Ylli, K; Hoffmann, D; Willmann, A; Becker, P; Folkmer, B; Manoli, Y

    2015-01-01

    Modern compact and low power sensors and systems are leading towards increasingly integrated wearable systems. One key bottleneck of this technology is the power supply. The use of energy harvesting techniques offers a way of supplying sensor systems without the need for batteries and maintenance. In this work we present the development and characterization of two inductive energy harvesters which exploit different characteristics of the human gait. A multi-coil topology harvester is presented which uses the swing motion of the foot. The second device is a shock-type harvester which is excited into resonance upon heel strike. Both devices were modeled and designed with the key constraint of device height in mind, in order to facilitate the integration into the shoe sole. The devices were characterized under different motion speeds and with two test subjects on a treadmill. An average power output of up to 0.84 mW is achieved with the swing harvester. With a total device volume including the housing of 21 cm 3 a power density of 40 μW cm −3 results. The shock harvester generates an average power output of up to 4.13 mW. The power density amounts to 86 μW cm −3 for the total device volume of 48 cm 3 . Difficulties and potential improvements are discussed briefly. (paper)

  18. Human Action Recognition Using Ordinal Measure of Accumulated Motion

    Directory of Open Access Journals (Sweden)

    Kim Wonjun

    2010-01-01

    Full Text Available This paper presents a method for recognizing human actions from a single query action video. We propose an action recognition scheme based on the ordinal measure of accumulated motion, which is robust to variations of appearances. To this end, we first define the accumulated motion image (AMI using image differences. Then the AMI of the query action video is resized to a subimage by intensity averaging and a rank matrix is generated by ordering the sample values in the sub-image. By computing the distances from the rank matrix of the query action video to the rank matrices of all local windows in the target video, local windows close to the query action are detected as candidates. To find the best match among the candidates, their energy histograms, which are obtained by projecting AMI values in horizontal and vertical directions, respectively, are compared with those of the query action video. The proposed method does not require any preprocessing task such as learning and segmentation. To justify the efficiency and robustness of our approach, the experiments are conducted on various datasets.

  19. Scavenging energy from human motion with tubular dielectric polymer

    Science.gov (United States)

    Jean-Mistral, Claire; Basrour, Skandar

    2010-04-01

    Scavenging energy from human motion is a challenge to supply low consumption systems for sport or medical applications. A promising solution is to use electroactive polymers and especially dielectric polymers to scavenge mechanical energy during walk. In this paper, we present a tubular dielectric generator which is the first step toward an integration of these structures into textiles. For a 10cm length and under a strain of 100%, the structure is able to scavenge 1.5μJ for a poling voltage of 200V and up to 40μJ for a poling voltage of 1000V. A 30cm length structure is finally compared to our previous planar structure, and the power management module for those structures is discussed.

  20. The role of human ventral visual cortex in motion perception

    Science.gov (United States)

    Saygin, Ayse P.; Lorenzi, Lauren J.; Egan, Ryan; Rees, Geraint; Behrmann, Marlene

    2013-01-01

    Visual motion perception is fundamental to many aspects of visual perception. Visual motion perception has long been associated with the dorsal (parietal) pathway and the involvement of the ventral ‘form’ (temporal) visual pathway has not been considered critical for normal motion perception. Here, we evaluated this view by examining whether circumscribed damage to ventral visual cortex impaired motion perception. The perception of motion in basic, non-form tasks (motion coherence and motion detection) and complex structure-from-motion, for a wide range of motion speeds, all centrally displayed, was assessed in five patients with a circumscribed lesion to either the right or left ventral visual pathway. Patients with a right, but not with a left, ventral visual lesion displayed widespread impairments in central motion perception even for non-form motion, for both slow and for fast speeds, and this held true independent of the integrity of areas MT/V5, V3A or parietal regions. In contrast with the traditional view in which only the dorsal visual stream is critical for motion perception, these novel findings implicate a more distributed circuit in which the integrity of the right ventral visual pathway is also necessary even for the perception of non-form motion. PMID:23983030

  1. Motion Segments Decomposition of RGB-D Sequences for Human Behavior Understanding

    OpenAIRE

    Devanne , Maxime; Berretti , Stefano; Pala , Pietro; Wannous , Hazem; Daoudi , Mohamed; Bimbo , Alberto ,

    2017-01-01

    International audience; In this paper, we propose a framework for analyzing and understanding human behavior from depth videos. The proposed solution first employs shape analysis of the human pose across time to decompose the full motion into short temporal segments representing elementary motions. Then, each segment is characterized by human motion and depth appearance around hand joints to describe the change in pose of the body and the interaction with objects. Finally , the sequence of te...

  2. Learning Silhouette Features for Control of Human Motion

    National Research Council Canada - National Science Library

    Ren, Liu; Shakhnarovich, Gregory; Hodgins, Jessica K; Pfister, Hanspeter; Viola, Paul A

    2004-01-01

    .... The system combines information about the user's motion contained in silhouettes from several viewpoints with domain knowledge contained in a motion capture database to interactively produce a high quality animation...

  3. Implied motion because of instability in Hokusai Manga activates the human motion-sensitive extrastriate visual cortex: an fMRI study of the impact of visual art.

    Science.gov (United States)

    Osaka, Naoyuki; Matsuyoshi, Daisuke; Ikeda, Takashi; Osaka, Mariko

    2010-03-10

    The recent development of cognitive neuroscience has invited inference about the neurosensory events underlying the experience of visual arts involving implied motion. We report functional magnetic resonance imaging study demonstrating activation of the human extrastriate motion-sensitive cortex by static images showing implied motion because of instability. We used static line-drawing cartoons of humans by Hokusai Katsushika (called 'Hokusai Manga'), an outstanding Japanese cartoonist as well as famous Ukiyoe artist. We found 'Hokusai Manga' with implied motion by depicting human bodies that are engaged in challenging tonic posture significantly activated the motion-sensitive visual cortex including MT+ in the human extrastriate cortex, while an illustration that does not imply motion, for either humans or objects, did not activate these areas under the same tasks. We conclude that motion-sensitive extrastriate cortex would be a critical region for perception of implied motion in instability.

  4. Donor-site morbidity of the radial forearm free flap versus the ulnar forearm free flap.

    Science.gov (United States)

    Hekner, Dominique D; Abbink, Jan H; van Es, Robert J; Rosenberg, Antoine; Koole, Ronald; Van Cann, Ellen M

    2013-08-01

    Donor-site morbidity following harvest of the radial forearm free flap was compared with that following harvest of the ulnar forearm free flap. Twenty-eight radial forearm and 27 ulnar forearm flaps were harvested in 55 patients with head and neck defects. Pressure perception was measured with Semmes-Weinstein monofilaments. Cold perception was tested with chloroethyl. Donor-site healing was evaluated. Patients were interviewed about grip and pinch strength and donor-site appearance. In the radial forearm free flap group, pressure perception and cold perception were reduced in the donor hand, whereas in the ulnar group, no differences were observed between the donor and unoperated hands. In the radial forearm group, 15 percent of patients experienced reduced strength in the donor hand, whereas in the ulnar forearm group, none of the patients reported reduced strength in the donor hand. In the radial forearm group, 14 percent had partial or complete loss of the skin graft, whereas in the ulnar forearm group, 4 percent had partial loss of the skin graft. In the radial forearm group, 18 percent of patients were dissatisfied with the appearance of the donor site, and no complaints were reported in the ulnar forearm group. The authors' study shows less donor site-morbidity following harvest of the ulnar forearm free flap than following harvest of the radial forearm free flap. These results emphasize that the ulnar forearm free flap should be considered as an alternative for the radial forearm free flap for reconstruction of soft-tissue defects. Therapeutic, III.

  5. Human motion retrieval from hand-drawn sketch.

    Science.gov (United States)

    Chao, Min-Wen; Lin, Chao-Hung; Assa, Jackie; Lee, Tong-Yee

    2012-05-01

    The rapid growth of motion capture data increases the importance of motion retrieval. The majority of the existing motion retrieval approaches are based on a labor-intensive step in which the user browses and selects a desired query motion clip from the large motion clip database. In this work, a novel sketching interface for defining the query is presented. This simple approach allows users to define the required motion by sketching several motion strokes over a drawn character, which requires less effort and extends the users’ expressiveness. To support the real-time interface, a specialized encoding of the motions and the hand-drawn query is required. Here, we introduce a novel hierarchical encoding scheme based on a set of orthonormal spherical harmonic (SH) basis functions, which provides a compact representation, and avoids the CPU/processing intensive stage of temporal alignment used by previous solutions. Experimental results show that the proposed approach can well retrieve the motions, and is capable of retrieve logically and numerically similar motions, which is superior to previous approaches. The user study shows that the proposed system can be a useful tool to input motion query if the users are familiar with it. Finally, an application of generating a 3D animation from a hand-drawn comics strip is demonstrated.

  6. Numerical and experimental investigations of human swimming motions.

    Science.gov (United States)

    Takagi, Hideki; Nakashima, Motomu; Sato, Yohei; Matsuuchi, Kazuo; Sanders, Ross H

    2016-08-01

    This paper reviews unsteady flow conditions in human swimming and identifies the limitations and future potential of the current methods of analysing unsteady flow. The capability of computational fluid dynamics (CFD) has been extended from approaches assuming steady-state conditions to consideration of unsteady/transient conditions associated with the body motion of a swimmer. However, to predict hydrodynamic forces and the swimmer's potential speeds accurately, more robust and efficient numerical methods are necessary, coupled with validation procedures, requiring detailed experimental data reflecting local flow. Experimental data obtained by particle image velocimetry (PIV) in this area are limited, because at present observations are restricted to a two-dimensional 1.0 m(2) area, though this could be improved if the output range of the associated laser sheet increased. Simulations of human swimming are expected to improve competitive swimming, and our review has identified two important advances relating to understanding the flow conditions affecting performance in front crawl swimming: one is a mechanism for generating unsteady fluid forces, and the other is a theory relating to increased speed and efficiency.

  7. Interactions between motion and form processing in the human visual system.

    Science.gov (United States)

    Mather, George; Pavan, Andrea; Bellacosa Marotti, Rosilari; Campana, Gianluca; Casco, Clara

    2013-01-01

    The predominant view of motion and form processing in the human visual system assumes that these two attributes are handled by separate and independent modules. Motion processing involves filtering by direction-selective sensors, followed by integration to solve the aperture problem. Form processing involves filtering by orientation-selective and size-selective receptive fields, followed by integration to encode object shape. It has long been known that motion signals can influence form processing in the well-known Gestalt principle of common fate; texture elements which share a common motion property are grouped into a single contour or texture region. However, recent research in psychophysics and neuroscience indicates that the influence of form signals on motion processing is more extensive than previously thought. First, the salience and apparent direction of moving lines depends on how the local orientation and direction of motion combine to match the receptive field properties of motion-selective neurons. Second, orientation signals generated by "motion-streaks" influence motion processing; motion sensitivity, apparent direction and adaptation are affected by simultaneously present orientation signals. Third, form signals generated by human body shape influence biological motion processing, as revealed by studies using point-light motion stimuli. Thus, form-motion integration seems to occur at several different levels of cortical processing, from V1 to STS.

  8. Interactions between motion and form processing in the human visual system

    Directory of Open Access Journals (Sweden)

    George eMather

    2013-05-01

    Full Text Available The predominant view of motion and form processing in the human visual system assumes that these two attributes are handled by separate and independent modules. Motion processing involves filtering by direction-selective sensors, followed by integration to solve the aperture problem. Form processing involves filtering by orientation-selective and size-selective receptive fields, followed by integration to encode object shape. It has long been known that motion signals can influence form processing in the well-known Gestalt principle of common fate; texture elements which share a common motion property are grouped into a single contour or texture region. However recent research in psychophysics and neuroscience indicates that the influence of form signals on motion processing is more extensive than previously thought. First, the salience and apparent direction of moving lines depends on how the local orientation and direction of motion combine to match the receptive field properties of motion-selective neurons. Second, orientation signals generated by ‘motion-streaks’ influence motion processing; motion sensitivity, apparent direction and adaptation are affected by simultaneously present orientation signals. Third, form signals generated by human body shape influence biological motion processing, as revealed by studies using point-light motion stimuli. Thus form-motion integration seems to occur at several different levels of cortical processing, from V1 to STS.

  9. Human torso phantom for imaging of heart with realistic modes of cardiac and respiratory motion

    Science.gov (United States)

    Boutchko, Rostyslav; Balakrishnan, Karthikayan; Gullberg, Grant T; O& #x27; Neil, James P

    2013-09-17

    A human torso phantom and its construction, wherein the phantom mimics respiratory and cardiac cycles in a human allowing acquisition of medical imaging data under conditions simulating patient cardiac and respiratory motion.

  10. A Survey of Advances in Vision-Based Human Motion Capture and Analysis

    DEFF Research Database (Denmark)

    Moeslund, Thomas B.; Hilton, Adrian; Krüger, Volker

    2006-01-01

    This survey reviews advances in human motion capture and analysis from 2000 to 2006, following a previous survey of papers up to 2000 Human motion capture continues to be an increasingly active research area in computer vision with over 350 publications over this period. A number of significant...... actions and behavior. This survey reviews recent trends in video based human capture and analysis, as well as discussing open problems for future research to achieve automatic visual analysis of human movement....

  11. Forearm Compartment Syndrome: Evaluation and Management.

    Science.gov (United States)

    Kistler, Justin M; Ilyas, Asif M; Thoder, Joseph J

    2018-02-01

    Compartment syndrome of the forearm is uncommon but can have devastating consequences. Compartment syndrome is a result of osseofascial swelling leading to decreased tissue perfusion and tissue necrosis. There are numerous causes of forearm compartment syndrome and high clinical suspicion must be maintained to avoid permanent disability. The most widely recognized symptoms include pain out of proportion and pain with passive stretch of the wrist and digits. Early diagnosis and decompressive fasciotomy are essential in the treatment of forearm compartment syndrome. Closure of fasciotomy wounds can often be accomplished by primary closure but many patients require additional forms of soft tissue coverage procedures. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. The 3D Human Motion Control Through Refined Video Gesture Annotation

    Science.gov (United States)

    Jin, Yohan; Suk, Myunghoon; Prabhakaran, B.

    In the beginning of computer and video game industry, simple game controllers consisting of buttons and joysticks were employed, but recently game consoles are replacing joystick buttons with novel interfaces such as the remote controllers with motion sensing technology on the Nintendo Wii [1] Especially video-based human computer interaction (HCI) technique has been applied to games, and the representative game is 'Eyetoy' on the Sony PlayStation 2. Video-based HCI technique has great benefit to release players from the intractable game controller. Moreover, in order to communicate between humans and computers, video-based HCI is very crucial since it is intuitive, easy to get, and inexpensive. On the one hand, extracting semantic low-level features from video human motion data is still a major challenge. The level of accuracy is really dependent on each subject's characteristic and environmental noises. Of late, people have been using 3D motion-capture data for visualizing real human motions in 3D space (e.g, 'Tiger Woods' in EA Sports, 'Angelina Jolie' in Bear-Wolf movie) and analyzing motions for specific performance (e.g, 'golf swing' and 'walking'). 3D motion-capture system ('VICON') generates a matrix for each motion clip. Here, a column is corresponding to a human's sub-body part and row represents time frames of data capture. Thus, we can extract sub-body part's motion only by selecting specific columns. Different from low-level feature values of video human motion, 3D human motion-capture data matrix are not pixel values, but is closer to human level of semantics.

  13. Tuning for temporal interval in human apparent motion detection.

    Science.gov (United States)

    Bours, Roger J E; Stuur, Sanne; Lankheet, Martin J M

    2007-01-08

    Detection of apparent motion in random dot patterns requires correlation across time and space. It has been difficult to study the temporal requirements for the correlation step because motion detection also depends on temporal filtering preceding correlation and on integration at the next levels. To specifically study tuning for temporal interval in the correlation step, we performed an experiment in which prefiltering and postintegration were held constant and in which we used a motion stimulus containing coherent motion for a single interval value only. The stimulus consisted of a sparse random dot pattern in which each dot was presented in two frames only, separated by a specified interval. On each frame, half of the dots were refreshed and the other half was a displaced reincarnation of the pattern generated one or several frames earlier. Motion energy statistics in such a stimulus do not vary from frame to frame, and the directional bias in spatiotemporal correlations is similar for different interval settings. We measured coherence thresholds for left-right direction discrimination by varying motion coherence levels in a Quest staircase procedure, as a function of both step size and interval. Results show that highest sensitivity was found for an interval of 17-42 ms, irrespective of viewing distance. The falloff at longer intervals was much sharper than previously described. Tuning for temporal interval was largely, but not completely, independent of step size. The optimal temporal interval slightly decreased with increasing step size. Similarly, the optimal step size decreased with increasing temporal interval.

  14. Real-time stylistic prediction for whole-body human motions.

    Science.gov (United States)

    Matsubara, Takamitsu; Hyon, Sang-Ho; Morimoto, Jun

    2012-01-01

    The ability to predict human motion is crucial in several contexts such as human tracking by computer vision and the synthesis of human-like computer graphics. Previous work has focused on off-line processes with well-segmented data; however, many applications such as robotics require real-time control with efficient computation. In this paper, we propose a novel approach called real-time stylistic prediction for whole-body human motions to satisfy these requirements. This approach uses a novel generative model to represent a whole-body human motion including rhythmic motion (e.g., walking) and discrete motion (e.g., jumping). The generative model is composed of a low-dimensional state (phase) dynamics and a two-factor observation model, allowing it to capture the diversity of motion styles in humans. A real-time adaptation algorithm was derived to estimate both state variables and style parameter of the model from non-stationary unlabeled sequential observations. Moreover, with a simple modification, the algorithm allows real-time adaptation even from incomplete (partial) observations. Based on the estimated state and style, a future motion sequence can be accurately predicted. In our implementation, it takes less than 15 ms for both adaptation and prediction at each observation. Our real-time stylistic prediction was evaluated for human walking, running, and jumping behaviors. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Interactions between motion and form processing in the human visual system

    OpenAIRE

    Mather, G.; Pavan, A.; Bellacosa Marotti, R.; Campana, G.; Casco, C.

    2013-01-01

    The predominant view of motion and form processing in the human visual system assumes that these two attributes are handled by separate and independent modules. Motion processing involves filtering by direction-selective sensors, followed by integration to solve the aperture problem. Form processing involves filtering by orientation-selective and size-selective receptive fields, followed by integration to encode object shape. It has long been known that motion signals can influence form proce...

  16. S3-3: Misbinding of Color and Motion in Human V2 Revealed by Color-Contingent Motion Adaptation

    Directory of Open Access Journals (Sweden)

    Fang Fang

    2012-10-01

    Full Text Available Wu, Kanai, & Shimojo (2004 Nature 429 262 described a compelling illusion demonstrating a steady-state misbinding of color and motion. Here, we took advantage of the illusion and performed psychophysical and fMRI adaptation experiments to explore the neural mechanism of color-motion misbinding. The stimulus subtended 20 deg by 14 deg of visual angle and contained two sheets of random dots, one sheet moving up and the other moving down. On the upward-moving sheet, dots in the right-end area (4 deg by 14 deg were red, and the rest of the dots were green. On the downward-moving sheet, dots in the right-end area were green, and the rest of the dots were red. When subjects fixated at the center of the stimulus, they bound the color and motion of the dots in the right-end area erroneously–the red dots appeared to move downwards and the green dots appeared to move upwards. In the psychophysical experiment, we measured the color-contingent motion aftereffect in the right-end area after adaptation to the illusory stimulus. A significant aftereffect was observed as if subjects had adapted to the perceived binding of color and motion, rather than the physical binding. For example, after adaptation, stationary red dots appeared to move upwards, and stationary green dots appeared to move downwards. In the fMRI experiment, we measured direction-selective motion adaptation effects in V1, V2, V3, V4, V3A/B, and V5. Relative to other cortical areas, V2 showed a much stronger adaptation effect to the perceived motion direction (rather than the physical direction for both the red and green dots. Significantly, the fMRI adaptation effect in V2 correlated with the color-contingent motion aftereffect across twelve subjects. This study provides the first human evidence that color and motion could be misbound at a very early stage of visual processing.

  17. Data Fusion Research of Triaxial Human Body Motion Gesture based on Decision Tree

    Directory of Open Access Journals (Sweden)

    Feihong Zhou

    2014-05-01

    Full Text Available The development status of human body motion gesture data fusion domestic and overseas has been analyzed. A triaxial accelerometer is adopted to develop a wearable human body motion gesture monitoring system aimed at old people healthcare. On the basis of a brief introduction of decision tree algorithm, the WEKA workbench is adopted to generate a human body motion gesture decision tree. At last, the classification quality of the decision tree has been validated through experiments. The experimental results show that the decision tree algorithm could reach an average predicting accuracy of 97.5 % with lower time cost.

  18. A Subject-Specific Kinematic Model to Predict Human Motion in Exoskeleton-Assisted Gait.

    Science.gov (United States)

    Torricelli, Diego; Cortés, Camilo; Lete, Nerea; Bertelsen, Álvaro; Gonzalez-Vargas, Jose E; Del-Ama, Antonio J; Dimbwadyo, Iris; Moreno, Juan C; Florez, Julian; Pons, Jose L

    2018-01-01

    The relative motion between human and exoskeleton is a crucial factor that has remarkable consequences on the efficiency, reliability and safety of human-robot interaction. Unfortunately, its quantitative assessment has been largely overlooked in the literature. Here, we present a methodology that allows predicting the motion of the human joints from the knowledge of the angular motion of the exoskeleton frame. Our method combines a subject-specific skeletal model with a kinematic model of a lower limb exoskeleton (H2, Technaid), imposing specific kinematic constraints between them. To calibrate the model and validate its ability to predict the relative motion in a subject-specific way, we performed experiments on seven healthy subjects during treadmill walking tasks. We demonstrate a prediction accuracy lower than 3.5° globally, and around 1.5° at the hip level, which represent an improvement up to 66% compared to the traditional approach assuming no relative motion between the user and the exoskeleton.

  19. Nonlinear Synchronization for Automatic Learning of 3D Pose Variability in Human Motion Sequences

    Directory of Open Access Journals (Sweden)

    Mozerov M

    2010-01-01

    Full Text Available A dense matching algorithm that solves the problem of synchronizing prerecorded human motion sequences, which show different speeds and accelerations, is proposed. The approach is based on minimization of MRF energy and solves the problem by using Dynamic Programming. Additionally, an optimal sequence is automatically selected from the input dataset to be a time-scale pattern for all other sequences. The paper utilizes an action specific model which automatically learns the variability of 3D human postures observed in a set of training sequences. The model is trained using the public CMU motion capture dataset for the walking action, and a mean walking performance is automatically learnt. Additionally, statistics about the observed variability of the postures and motion direction are also computed at each time step. The synchronized motion sequences are used to learn a model of human motion for action recognition and full-body tracking purposes.

  20. Elastic robust intramedullary nailing for forearm fracture in children

    Directory of Open Access Journals (Sweden)

    Wasem, Jürgen

    2006-01-01

    Full Text Available Background: Forearm fractures are the most common fractures in children (23% of all fractures. Basically there are two treatment options available for diaphyseal forearm fractures in children: closed reduction with cast immobilisation (conservative therapy and the elastic stable intramedullary nailing (ESIN. Treatment decision is influenced by the doctor's estimation of fracture instability. Stable fractures can be treated conservatively whereas instable forearm shaft fractures can be treated according the following three treatment strategies: 1. conservative therapy in an outpatient setting 2. conservative therapy in the operating room in attendance to change to ESIN in case that no stabilisation can be achieved with cast immobilisation 3. immediate treatment with ESIN in the operating room. Objectives: Aim of this Health Technology Assessment (HTA report is to assess and report the published evidence concerning effectiveness and cost-effectiveness of ESIN as a treatment option for diaphyseal forearm fractures in children and to identify future research need. Important parameters for the assessment of effectiveness are objective parameters (axis deviation, losses of motion, and numbers of reductions in case of redislocations and subjective parameters (pain or impairment in quality of life. Furthermore, a health economic evaluation shall be done which refers to the costs of the different therapy strategies. Methods: An extensive, systematic literature search in medical, economic, and HTA literature databases was performed. Relevant data were extracted and synthesised. Results: Three cohort studies and seven case series have been identified. Controlled clinical studies, systematic reviews and/or HTA reports that gave evidence to answer the own study question have not been found. The identified studies partly differed in respect of defined indication for ESIN, study population and treatment strategies. For that reason comparability of results was

  1. WiFi-Based Real-Time Calibration-Free Passive Human Motion Detection

    Directory of Open Access Journals (Sweden)

    Liangyi Gong

    2015-12-01

    Full Text Available With the rapid development of WLAN technology, wireless device-free passive human detection becomes a newly-developing technique and holds more potential to worldwide and ubiquitous smart applications. Recently, indoor fine-grained device-free passive human motion detection based on the PHY layer information is rapidly developed. Previous wireless device-free passive human detection systems either rely on deploying specialized systems with dense transmitter-receiver links or elaborate off-line training process, which blocks rapid deployment and weakens system robustness. In the paper, we explore to research a novel fine-grained real-time calibration-free device-free passive human motion via physical layer information, which is independent of indoor scenarios and needs no prior-calibration and normal profile. We investigate sensitivities of amplitude and phase to human motion, and discover that phase feature is more sensitive to human motion, especially to slow human motion. Aiming at lightweight and robust device-free passive human motion detection, we develop two novel and practical schemes: short-term averaged variance ratio (SVR and long-term averaged variance ratio (LVR. We realize system design with commercial WiFi devices and evaluate it in typical multipath-rich indoor scenarios. As demonstrated in the experiments, our approach can achieve a high detection rate and low false positive rate.

  2. WiFi-Based Real-Time Calibration-Free Passive Human Motion Detection.

    Science.gov (United States)

    Gong, Liangyi; Yang, Wu; Man, Dapeng; Dong, Guozhong; Yu, Miao; Lv, Jiguang

    2015-12-21

    With the rapid development of WLAN technology, wireless device-free passive human detection becomes a newly-developing technique and holds more potential to worldwide and ubiquitous smart applications. Recently, indoor fine-grained device-free passive human motion detection based on the PHY layer information is rapidly developed. Previous wireless device-free passive human detection systems either rely on deploying specialized systems with dense transmitter-receiver links or elaborate off-line training process, which blocks rapid deployment and weakens system robustness. In the paper, we explore to research a novel fine-grained real-time calibration-free device-free passive human motion via physical layer information, which is independent of indoor scenarios and needs no prior-calibration and normal profile. We investigate sensitivities of amplitude and phase to human motion, and discover that phase feature is more sensitive to human motion, especially to slow human motion. Aiming at lightweight and robust device-free passive human motion detection, we develop two novel and practical schemes: short-term averaged variance ratio (SVR) and long-term averaged variance ratio (LVR). We realize system design with commercial WiFi devices and evaluate it in typical multipath-rich indoor scenarios. As demonstrated in the experiments, our approach can achieve a high detection rate and low false positive rate.

  3. WiFi-Based Real-Time Calibration-Free Passive Human Motion Detection †

    Science.gov (United States)

    Gong, Liangyi; Yang, Wu; Man, Dapeng; Dong, Guozhong; Yu, Miao; Lv, Jiguang

    2015-01-01

    With the rapid development of WLAN technology, wireless device-free passive human detection becomes a newly-developing technique and holds more potential to worldwide and ubiquitous smart applications. Recently, indoor fine-grained device-free passive human motion detection based on the PHY layer information is rapidly developed. Previous wireless device-free passive human detection systems either rely on deploying specialized systems with dense transmitter-receiver links or elaborate off-line training process, which blocks rapid deployment and weakens system robustness. In the paper, we explore to research a novel fine-grained real-time calibration-free device-free passive human motion via physical layer information, which is independent of indoor scenarios and needs no prior-calibration and normal profile. We investigate sensitivities of amplitude and phase to human motion, and discover that phase feature is more sensitive to human motion, especially to slow human motion. Aiming at lightweight and robust device-free passive human motion detection, we develop two novel and practical schemes: short-term averaged variance ratio (SVR) and long-term averaged variance ratio (LVR). We realize system design with commercial WiFi devices and evaluate it in typical multipath-rich indoor scenarios. As demonstrated in the experiments, our approach can achieve a high detection rate and low false positive rate. PMID:26703612

  4. Three dimensional monocular human motion analysis in end-effector space

    DEFF Research Database (Denmark)

    Hauberg, Søren; Lapuyade, Jerome; Engell-Nørregård, Morten Pol

    2009-01-01

    In this paper, we present a novel approach to three dimensional human motion estimation from monocular video data. We employ a particle filter to perform the motion estimation. The novelty of the method lies in the choice of state space for the particle filter. Using a non-linear inverse kinemati...

  5. Comparison of Flight Simulators Based on Human Motion Perception Metrics

    Science.gov (United States)

    Valente Pais, Ana R.; Correia Gracio, Bruno J.; Kelly, Lon C.; Houck, Jacob A.

    2015-01-01

    In flight simulation, motion filters are used to transform aircraft motion into simulator motion. When looking for the best match between visual and inertial amplitude in a simulator, researchers have found that there is a range of inertial amplitudes, rather than a single inertial value, that is perceived by subjects as optimal. This zone, hereafter referred to as the optimal zone, seems to correlate to the perceptual coherence zones measured in flight simulators. However, no studies were found in which these two zones were compared. This study investigates the relation between the optimal and the coherence zone measurements within and between different simulators. Results show that for the sway axis, the optimal zone lies within the lower part of the coherence zone. In addition, it was found that, whereas the width of the coherence zone depends on the visual amplitude and frequency, the width of the optimal zone remains constant.

  6. Mathematical Modeling and Evaluation of Human Motions in Physical Therapy Using Mixture Density Neural Networks.

    Science.gov (United States)

    Vakanski, A; Ferguson, J M; Lee, S

    2016-12-01

    The objective of the proposed research is to develop a methodology for modeling and evaluation of human motions, which will potentially benefit patients undertaking a physical rehabilitation therapy (e.g., following a stroke or due to other medical conditions). The ultimate aim is to allow patients to perform home-based rehabilitation exercises using a sensory system for capturing the motions, where an algorithm will retrieve the trajectories of a patient's exercises, will perform data analysis by comparing the performed motions to a reference model of prescribed motions, and will send the analysis results to the patient's physician with recommendations for improvement. The modeling approach employs an artificial neural network, consisting of layers of recurrent neuron units and layers of neuron units for estimating a mixture density function over the spatio-temporal dependencies within the human motion sequences. Input data are sequences of motions related to a prescribed exercise by a physiotherapist to a patient, and recorded with a motion capture system. An autoencoder subnet is employed for reducing the dimensionality of captured sequences of human motions, complemented with a mixture density subnet for probabilistic modeling of the motion data using a mixture of Gaussian distributions. The proposed neural network architecture produced a model for sets of human motions represented with a mixture of Gaussian density functions. The mean log-likelihood of observed sequences was employed as a performance metric in evaluating the consistency of a subject's performance relative to the reference dataset of motions. A publically available dataset of human motions captured with Microsoft Kinect was used for validation of the proposed method. The article presents a novel approach for modeling and evaluation of human motions with a potential application in home-based physical therapy and rehabilitation. The described approach employs the recent progress in the field of

  7. A human motion model based on maps for navigation systems

    Directory of Open Access Journals (Sweden)

    Kaiser Susanna

    2011-01-01

    Full Text Available Abstract Foot-mounted indoor positioning systems work remarkably well when using additionally the knowledge of floor-plans in the localization algorithm. Walls and other structures naturally restrict the motion of pedestrians. No pedestrian can walk through walls or jump from one floor to another when considering a building with different floor-levels. By incorporating known floor-plans in sequential Bayesian estimation processes such as particle filters (PFs, long-term error stability can be achieved as long as the map is sufficiently accurate and the environment sufficiently constraints pedestrians' motion. In this article, a new motion model based on maps and floor-plans is introduced that is capable of weighting the possible headings of the pedestrian as a function of the local environment. The motion model is derived from a diffusion algorithm that makes use of the principle of a source effusing gas and is used in the weighting step of a PF implementation. The diffusion algorithm is capable of including floor-plans as well as maps with areas of different degrees of accessibility. The motion model more effectively represents the probability density function of possible headings that are restricted by maps and floor-plans than a simple binary weighting of particles (i.e., eliminating those that crossed walls and keeping the rest. We will show that the motion model will help for obtaining better performance in critical navigation scenarios where two or more modes may be competing for some of the time (multi-modal scenarios.

  8. Analyzing the effects of human-aware motion planning on close-proximity human-robot collaboration.

    Science.gov (United States)

    Lasota, Przemyslaw A; Shah, Julie A

    2015-02-01

    The objective of this work was to examine human response to motion-level robot adaptation to determine its effect on team fluency, human satisfaction, and perceived safety and comfort. The evaluation of human response to adaptive robotic assistants has been limited, particularly in the realm of motion-level adaptation. The lack of true human-in-the-loop evaluation has made it impossible to determine whether such adaptation would lead to efficient and satisfying human-robot interaction. We conducted an experiment in which participants worked with a robot to perform a collaborative task. Participants worked with an adaptive robot incorporating human-aware motion planning and with a baseline robot using shortest-path motions. Team fluency was evaluated through a set of quantitative metrics, and human satisfaction and perceived safety and comfort were evaluated through questionnaires. When working with the adaptive robot, participants completed the task 5.57% faster, with 19.9% more concurrent motion, 2.96% less human idle time, 17.3% less robot idle time, and a 15.1% greater separation distance. Questionnaire responses indicated that participants felt safer and more comfortable when working with an adaptive robot and were more satisfied with it as a teammate than with the standard robot. People respond well to motion-level robot adaptation, and significant benefits can be achieved from its use in terms of both human-robot team fluency and human worker satisfaction. Our conclusion supports the development of technologies that could be used to implement human-aware motion planning in collaborative robots and the use of this technique for close-proximity human-robot collaboration.

  9. Decoding conjunctions of direction-of-motion and binocular disparity from human visual cortex.

    Science.gov (United States)

    Seymour, Kiley J; Clifford, Colin W G

    2012-05-01

    Motion and binocular disparity are two features in our environment that share a common correspondence problem. Decades of psychophysical research dedicated to understanding stereopsis suggest that these features interact early in human visual processing to disambiguate depth. Single-unit recordings in the monkey also provide evidence for the joint encoding of motion and disparity across much of the dorsal visual stream. Here, we used functional MRI and multivariate pattern analysis to examine where in the human brain conjunctions of motion and disparity are encoded. Subjects sequentially viewed two stimuli that could be distinguished only by their conjunctions of motion and disparity. Specifically, each stimulus contained the same feature information (leftward and rightward motion and crossed and uncrossed disparity) but differed exclusively in the way these features were paired. Our results revealed that a linear classifier could accurately decode which stimulus a subject was viewing based on voxel activation patterns throughout the dorsal visual areas and as early as V2. This decoding success was conditional on some voxels being individually sensitive to the unique conjunctions comprising each stimulus, thus a classifier could not rely on independent information about motion and binocular disparity to distinguish these conjunctions. This study expands on evidence that disparity and motion interact at many levels of human visual processing, particularly within the dorsal stream. It also lends support to the idea that stereopsis is subserved by early mechanisms also tuned to direction of motion.

  10. A triboelectric motion sensor in wearable body sensor network for human activity recognition.

    Science.gov (United States)

    Hui Huang; Xian Li; Ye Sun

    2016-08-01

    The goal of this study is to design a novel triboelectric motion sensor in wearable body sensor network for human activity recognition. Physical activity recognition is widely used in well-being management, medical diagnosis and rehabilitation. Other than traditional accelerometers, we design a novel wearable sensor system based on triboelectrification. The triboelectric motion sensor can be easily attached to human body and collect motion signals caused by physical activities. The experiments are conducted to collect five common activity data: sitting and standing, walking, climbing upstairs, downstairs, and running. The k-Nearest Neighbor (kNN) clustering algorithm is adopted to recognize these activities and validate the feasibility of this new approach. The results show that our system can perform physical activity recognition with a successful rate over 80% for walking, sitting and standing. The triboelectric structure can also be used as an energy harvester for motion harvesting due to its high output voltage in random low-frequency motion.

  11. Scavenging energy from the motion of human lower limbs via a piezoelectric energy harvester

    Science.gov (United States)

    Fan, Kangqi; Yu, Bo; Zhu, Yingmin; Liu, Zhaohui; Wang, Liansong

    2017-03-01

    Scavenging energy from human motion through piezoelectric transduction has been considered as a feasible alternative to batteries for powering portable devices and realizing self-sustained devices. To date, most piezoelectric energy harvesters (PEHs) developed can only collect energy from the uni-directional mechanical vibration. This deficiency severely limits their applicability to human motion energy harvesting because the human motion involves diverse mechanical motions. In this paper, a novel PEH is proposed to harvest energy from the motion of human lower limbs. This PEH is composed of two piezoelectric cantilever beams, a sleeve and a ferromagnetic ball. The two beams are designed to sense the vibration along the tibial axis and conduct piezoelectric conversion. The ball senses the leg swing and actuates the two beams to vibrate via magnetic coupling. Theoretical and experimental studies indicate that the proposed PEH can scavenge energy from both the vibration and the swing. During each stride, the PEH can produce multiple peaks in voltage output, which is attributed to the superposition of different excitations. Moreover, the root-mean-square (RMS) voltage output of the PEH increases when the walking speed ranges from 2 to 8 km/h. In addition, the ultra-low frequencies of human motion are also up-converted by the proposed design.

  12. Human error identification for laparoscopic surgery: Development of a motion economy perspective.

    Science.gov (United States)

    Al-Hakim, Latif; Sevdalis, Nick; Maiping, Tanaphon; Watanachote, Damrongpan; Sengupta, Shomik; Dissaranan, Charuspong

    2015-09-01

    This study postulates that traditional human error identification techniques fail to consider motion economy principles and, accordingly, their applicability in operating theatres may be limited. This study addresses this gap in the literature with a dual aim. First, it identifies the principles of motion economy that suit the operative environment and second, it develops a new error mode taxonomy for human error identification techniques which recognises motion economy deficiencies affecting the performance of surgeons and predisposing them to errors. A total of 30 principles of motion economy were developed and categorised into five areas. A hierarchical task analysis was used to break down main tasks of a urological laparoscopic surgery (hand-assisted laparoscopic nephrectomy) to their elements and the new taxonomy was used to identify errors and their root causes resulting from violation of motion economy principles. The approach was prospectively tested in 12 observed laparoscopic surgeries performed by 5 experienced surgeons. A total of 86 errors were identified and linked to the motion economy deficiencies. Results indicate the developed methodology is promising. Our methodology allows error prevention in surgery and the developed set of motion economy principles could be useful for training surgeons on motion economy principles. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  13. Ulnar nerve paralysis after forearm bone fracture

    Directory of Open Access Journals (Sweden)

    Carlos Roberto Schwartsmann

    2016-08-01

    Full Text Available ABSTRACT Paralysis or nerve injury associated with fractures of forearm bones fracture is rare and is more common in exposed fractures with large soft-tissue injuries. Ulnar nerve paralysis is a rare condition associated with closed fractures of the forearm. In most cases, the cause of paralysis is nerve contusion, which evolves with neuropraxia. However, nerve lacerations and entrapment at the fracture site always need to be borne in mind. This becomes more important when neuropraxia appears or worsens after reduction of a closed fracture of the forearm has been completed. The importance of diagnosing this injury and differentiating its features lies in the fact that, depending on the type of lesion, different types of management will be chosen.

  14. Measuring Accurate Body Parameters of Dressed Humans with Large-Scale Motion Using a Kinect Sensor

    Directory of Open Access Journals (Sweden)

    Sidan Du

    2013-08-01

    Full Text Available Non-contact human body measurement plays an important role in surveillance, physical healthcare, on-line business and virtual fitting. Current methods for measuring the human body without physical contact usually cannot handle humans wearing clothes, which limits their applicability in public environments. In this paper, we propose an effective solution that can measure accurate parameters of the human body with large-scale motion from a Kinect sensor, assuming that the people are wearing clothes. Because motion can drive clothes attached to the human body loosely or tightly, we adopt a space-time analysis to mine the information across the posture variations. Using this information, we recover the human body, regardless of the effect of clothes, and measure the human body parameters accurately. Experimental results show that our system can perform more accurate parameter estimation on the human body than state-of-the-art methods.

  15. Sensitive and Flexible Polymeric Strain Sensor for Accurate Human Motion Monitoring.

    Science.gov (United States)

    Khan, Hassan; Razmjou, Amir; Ebrahimi Warkiani, Majid; Kottapalli, Ajay; Asadnia, Mohsen

    2018-02-01

    Flexible electronic devices offer the capability to integrate and adapt with human body. These devices are mountable on surfaces with various shapes, which allow us to attach them to clothes or directly onto the body. This paper suggests a facile fabrication strategy via electrospinning to develop a stretchable, and sensitive poly (vinylidene fluoride) nanofibrous strain sensor for human motion monitoring. A complete characterization on the single PVDF nano fiber has been performed. The charge generated by PVDF electrospun strain sensor changes was employed as a parameter to control the finger motion of the robotic arm. As a proof of concept, we developed a smart glove with five sensors integrated into it to detect the fingers motion and transfer it to a robotic hand. Our results shows that the proposed strain sensors are able to detect tiny motion of fingers and successfully run the robotic hand.

  16. Sensitive and Flexible Polymeric Strain Sensor for Accurate Human Motion Monitoring

    Directory of Open Access Journals (Sweden)

    Hassan Khan

    2018-02-01

    Full Text Available Flexible electronic devices offer the capability to integrate and adapt with human body. These devices are mountable on surfaces with various shapes, which allow us to attach them to clothes or directly onto the body. This paper suggests a facile fabrication strategy via electrospinning to develop a stretchable, and sensitive poly (vinylidene fluoride nanofibrous strain sensor for human motion monitoring. A complete characterization on the single PVDF nano fiber has been performed. The charge generated by PVDF electrospun strain sensor changes was employed as a parameter to control the finger motion of the robotic arm. As a proof of concept, we developed a smart glove with five sensors integrated into it to detect the fingers motion and transfer it to a robotic hand. Our results shows that the proposed strain sensors are able to detect tiny motion of fingers and successfully run the robotic hand.

  17. Motion in Human and Machine: A Virtual Fatigue Approach

    NARCIS (Netherlands)

    Potkonjak, V.; Kostic, D.; Rasic, M.; Djordjevic, G.

    2002-01-01

    Achieving human-like behavior of a robot is a key issue of the paper. Redundancy in the inverse kinematics problem is resolved using a biological analogue. It is shown that by means of "virtual fatigue" functions, it is possible to generate robot movements similar to movements of a human arm subject

  18. The development of human factors experimental evaluation technology - 3-dimensional measurement system for motion analysis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kyung Soo; Pan, Young Hwan; Lee, Ahn Jae; Lee, Kyung Tae; Lim, Chi Hwan; Chang, Pil Sik; Lee, Seok Woo; Han, Sung Wook; Park, Chul Wook [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    1996-07-01

    Measurement of human motion is important in the application of ergonomics. We developed a system which can measure body movement, especially= hand movement using advanced direct video measurement technology. This system has as dynamic accuracy with 1% error and the sampling rate to 6 - 10 Hz, and can analyse the trajectory and speed of the marker. The use of passive marker obviates the need for a marker telemetry system and minimize motion disruption. 18 refs., 4 tabs., 6 figs. (author)

  19. Human-motion energy harvester for autonomous body area sensors

    Science.gov (United States)

    Geisler, M.; Boisseau, S.; Perez, M.; Gasnier, P.; Willemin, J.; Ait-Ali, I.; Perraud, S.

    2017-03-01

    This paper reports on a method to optimize an electromagnetic energy harvester converting the low-frequency body motion and aimed at powering wireless body area sensors. This method is based on recorded accelerations, and mechanical and transduction models that enable an efficient joint optimization of the structural parameters. An optimized prototype of 14.8 mmØ × 52 mm, weighting 20 g, has generated up to 4.95 mW in a resistive load when worn at the arm during a run, and 6.57 mW when hand-shaken. Among the inertial electromagnetic energy harvesters reported so far, this one exhibits one of the highest power densities (up to 730 μW cm-3). The energy harvester was finally used to power a bluetooth low energy wireless sensor node with accelerations measurements at 25 Hz.

  20. Music recommendation according to human motion based on kernel CCA-based relationship

    Science.gov (United States)

    Ohkushi, Hiroyuki; Ogawa, Takahiro; Haseyama, Miki

    2011-12-01

    In this article, a method for recommendation of music pieces according to human motions based on their kernel canonical correlation analysis (CCA)-based relationship is proposed. In order to perform the recommendation between different types of multimedia data, i.e., recommendation of music pieces from human motions, the proposed method tries to estimate their relationship. Specifically, the correlation based on kernel CCA is calculated as the relationship in our method. Since human motions and music pieces have various time lengths, it is necessary to calculate the correlation between time series having different lengths. Therefore, new kernel functions for human motions and music pieces, which can provide similarities between data that have different time lengths, are introduced into the calculation of the kernel CCA-based correlation. This approach effectively provides a solution to the conventional problem of not being able to calculate the correlation from multimedia data that have various time lengths. Therefore, the proposed method can perform accurate recommendation of best matched music pieces according to a target human motion from the obtained correlation. Experimental results are shown to verify the performance of the proposed method.

  1. Forearm Compartment Syndrome Caused by Reperfusion Injury

    Directory of Open Access Journals (Sweden)

    Ufuk Sayar

    2014-01-01

    Full Text Available Compartment syndrome is commonly seen following lower extremity ischemia. However, upper extremities’ compartment syndrome, especially after any vascular surgical procedures, is infrequent. Herein we report a case of an acute forearm compartment syndrome that was developed after delayed brachial artery embolectomy.

  2. Forearm interosseous membrane imaging and anatomy.

    Science.gov (United States)

    McGinley, Joseph C; Roach, Neil; Gaughan, John P; Kozin, Scott H

    2004-10-01

    To determine the regional thickness variation of the interosseous membrane (IOM) along the forearm and validate magnetic resonance imaging of the IOM with laser micrometry. Axial thickness measurements of 12 cadaver forearms were obtained using magnetic resonance imaging (MRI) at radial, central, and ulnar locations. The specimens were dissected, and IOM thickness measured using a laser micrometer. MRI and laser measurements of the main and oblique IOM bundles were compared. An axial thickness profile was plotted versus forearm length, and radial, central, and ulnar positions were compared. The main bundle thickness was 2.18+/-0.20 mm using laser micrometry, which was not significantly different from MRI measurements (1.86+/-0.25 mm, p=0.11, power = 0.84). The dorsal oblique bundle thickness was not significantly different between measurement methods (2.93+/-0.77 mm and 3.30+/-1.64 mm using laser micrometry and MRI respectively, p=0.75, power = 0.04). Both methods demonstrated a progressive increase in thickness proximally within the forearm. MRI measurements demonstrated a significantly greater thickness increase in the radial location compared to the central location (slope = 2.26 and 1.05, r(2)=0.31 and 0.12 respectively, p0.05). Our findings describe the varying IOM anatomy using MRI, and determined the location of the clinically important IOM fiber bundles. This study confirms the accuracy of MR imaging of the IOM by comparison with a laser micrometer, and demonstrates the thickness variation along the forearm. This information may be used to identify changes in IOM anatomy with both acute IOM injury and chronic fiber attenuation.

  3. Forearm interosseous membrane imaging and anatomy

    Energy Technology Data Exchange (ETDEWEB)

    McGinley, Joseph C. [Temple University, School of Medicine, Philadelphia, Pennsylvania (United States); Roach, Neil [Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia, Pennsylvania (United States); Gaughan, John P. [Temple University, Department of Biostatistics, Philadelphia, Pennsylvania (United States); Kozin, Scott H. [Shriners Hospitals for Children, Pediatric Hand and Upper Extremity Surgery, Philadelphia (United States); Temple University, Department of Orthopaedic Surgery, Philadelphia, Pennsylvania (United States)

    2004-10-01

    To determine the regional thickness variation of the interosseous membrane (IOM) along the forearm and validate magnetic resonance imaging of the IOM with laser micrometry. Axial thickness measurements of 12 cadaver forearms were obtained using magnetic resonance imaging (MRI) at radial, central, and ulnar locations. The specimens were dissected, and IOM thickness measured using a laser micrometer. MRI and laser measurements of the main and oblique IOM bundles were compared. An axial thickness profile was plotted versus forearm length, and radial, central, and ulnar positions were compared. The main bundle thickness was 2.18{+-}0.20 mm using laser micrometry, which was not significantly different from MRI measurements (1.86{+-}0.25 mm, p=0.11, power = 0.84). The dorsal oblique bundle thickness was not significantly different between measurement methods (2.93{+-}0.77 mm and 3.30{+-}1.64 mm using laser micrometry and MRI respectively, p=0.75, power = 0.04). Both methods demonstrated a progressive increase in thickness proximally within the forearm. MRI measurements demonstrated a significantly greater thickness increase in the radial location compared to the central location (slope = 2.26 and 1.05, r{sup 2}=0.31 and 0.12 respectively, p<0.05). The ulnar slope was not significantly different from zero (r{sup 2}=0.02, p>0.05). Our findings describe the varying IOM anatomy using MRI, and determined the location of the clinically important IOM fiber bundles. This study confirms the accuracy of MR imaging of the IOM by comparison with a laser micrometer, and demonstrates the thickness variation along the forearm. This information may be used to identify changes in IOM anatomy with both acute IOM injury and chronic fiber attenuation. (orig.)

  4. Forearm interosseous membrane imaging and anatomy

    International Nuclear Information System (INIS)

    McGinley, Joseph C.; Roach, Neil; Gaughan, John P.; Kozin, Scott H.

    2004-01-01

    To determine the regional thickness variation of the interosseous membrane (IOM) along the forearm and validate magnetic resonance imaging of the IOM with laser micrometry. Axial thickness measurements of 12 cadaver forearms were obtained using magnetic resonance imaging (MRI) at radial, central, and ulnar locations. The specimens were dissected, and IOM thickness measured using a laser micrometer. MRI and laser measurements of the main and oblique IOM bundles were compared. An axial thickness profile was plotted versus forearm length, and radial, central, and ulnar positions were compared. The main bundle thickness was 2.18±0.20 mm using laser micrometry, which was not significantly different from MRI measurements (1.86±0.25 mm, p=0.11, power = 0.84). The dorsal oblique bundle thickness was not significantly different between measurement methods (2.93±0.77 mm and 3.30±1.64 mm using laser micrometry and MRI respectively, p=0.75, power = 0.04). Both methods demonstrated a progressive increase in thickness proximally within the forearm. MRI measurements demonstrated a significantly greater thickness increase in the radial location compared to the central location (slope = 2.26 and 1.05, r 2 =0.31 and 0.12 respectively, p 2 =0.02, p>0.05). Our findings describe the varying IOM anatomy using MRI, and determined the location of the clinically important IOM fiber bundles. This study confirms the accuracy of MR imaging of the IOM by comparison with a laser micrometer, and demonstrates the thickness variation along the forearm. This information may be used to identify changes in IOM anatomy with both acute IOM injury and chronic fiber attenuation. (orig.)

  5. Motion Cueing Algorithm Development: Human-Centered Linear and Nonlinear Approaches

    Science.gov (United States)

    Houck, Jacob A. (Technical Monitor); Telban, Robert J.; Cardullo, Frank M.

    2005-01-01

    While the performance of flight simulator motion system hardware has advanced substantially, the development of the motion cueing algorithm, the software that transforms simulated aircraft dynamics into realizable motion commands, has not kept pace. Prior research identified viable features from two algorithms: the nonlinear "adaptive algorithm", and the "optimal algorithm" that incorporates human vestibular models. A novel approach to motion cueing, the "nonlinear algorithm" is introduced that combines features from both approaches. This algorithm is formulated by optimal control, and incorporates a new integrated perception model that includes both visual and vestibular sensation and the interaction between the stimuli. Using a time-varying control law, the matrix Riccati equation is updated in real time by a neurocomputing approach. Preliminary pilot testing resulted in the optimal algorithm incorporating a new otolith model, producing improved motion cues. The nonlinear algorithm vertical mode produced a motion cue with a time-varying washout, sustaining small cues for longer durations and washing out large cues more quickly compared to the optimal algorithm. The inclusion of the integrated perception model improved the responses to longitudinal and lateral cues. False cues observed with the NASA adaptive algorithm were absent. The neurocomputing approach was crucial in that the number of presentations of an input vector could be reduced to meet the real time requirement without degrading the quality of the motion cues.

  6. Perforator anatomy of the radial forearm free flap versus the ulnar forearm free flap for head and neck reconstruction

    NARCIS (Netherlands)

    Hekner, D.D.; Roeling, TAP; van Cann, EM

    The aim of this study was to investigate the vascular anatomy of the distal forearm in order to optimize the choice between the radial forearm free flap and the ulnar forearm free flap and to select the best site to harvest the flap. The radial and ulnar arteries of seven fresh cadavers were

  7. Histaminergic and cholinergic neuron systems in the impairment of human thermoregulation during motion sickness.

    Science.gov (United States)

    Nobel, Gerard; Tribukait, Arne; Mekjavic, Igor B; Eiken, Ola

    2010-05-31

    Motion sickness (MS) exaggerates body cooling during cold-water immersion. The aim of the present study was to investigate whether such MS-induced predisposition to hypothermia is influenced by two anti-MS drugs: the histamine-receptor blocker dimenhydrinate (DMH) and the muscarine-receptor blocker scopolamine (Scop). Nine healthy male subjects were immersed in 15 degrees C water for a maximum of 90min in five conditions: (1) control (CN): no medication, no MS provocation; (2) MS-control (MS-CN): no medication, MS provocation; (3) MS-placebo (MS-P): placebo DMH and placebo Scop, MS provocation; (4) MS-DMH: DMH and placebo Scop, MS provocation; (5) MS-Scop: Scop and placebo DMH, MS provocation. MS was induced by use of a rotating chair. Throughout the experiments rectal temperature (T(re)), the difference in temperature between the non-immersed right forearm and third finger (T(ff)) as an index of peripheral vasoconstriction, and oxygen uptake (VO(2)) as a measure of shivering thermogenesis, were recorded. DMH and Scop were similarly efficacious in ameliorating nausea. The fall in T(re) was greater in the MS-CN and MS-P conditions than in the CN condition. DMH, but not Scop, prevented the MS-induced increase in body-core cooling. MS attenuated the cold-induced vasoconstriction, an effect which was fully prevented by DMH but only partially by Scop. MS provocation did not affect VO(2) in any condition. The results suggest that the MS-induced predisposition to hypothermia is predominantly mediated by histaminergic mechanisms and that DMH might be useful in conjunction with maritime accidents or other scenarios where exposure to cold and MS are imminent features. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  8. Procedure Oriented Torsional Anatomy of the Forearm for Spasticity Injection.

    Science.gov (United States)

    Chiou-Tan, Faye; Cianca, John; John, Joslyn; Furr-Stimming, Erin; Pandit, Sindhu; Taber, Katherine H

    2015-01-01

    : This is the second in a series of articles related to the concept of "torsional" anatomy. The objective of this article is to provide musculoskeletal ultrasound (MSKUS) anatomy of the forearm in the position of hemispastic flexion as a reference relevant to needle procedures. The MSKUS images were obtained in a healthy human subject. Marker dots were placed over common injection sites in the forearm for spasticity. The MSKUS probe was centered over each dot to obtain a cross-sectional view. A pair of MSKUS images was recorded for each site: the first in anatomic neutral and second in hemiparetic spastic position. The images were compared side to side. In addition, a video recording was made at each site to track the movement of the muscles and nerves during internal rotation. The pronator teres (PT) rotated medially and the brachialis and biceps tendon rotated in view. In addition, the median nerve became more superficial. The flexor carpi radialis rotated medially and was replaced by PT and the median nerve. The flexor carpi ulnaris and flexor digitorum profundus rotated medially and were replaced by the flexor carpi radialis, PT and median nerve. The flexor digitorum superficialis was replaced by the brachioradialis, extensor carpi radialis brevis, and radial nerve. The brachioradialis was replaced by the extensor carpi radialis brevis and extensor digitorum communis. Intended muscle targets rotate out of view and injection range. These are replaced by other muscles and nerves that could inadvertently be injected. This potentially could result in both increased complications and decreased efficacy of the procedure. It is hoped that this series of images will increase the accuracy and safety of needle placement for spasticity injections in the forearm.

  9. A Subject-Specific Kinematic Model to Predict Human Motion in Exoskeleton-Assisted Gait

    Science.gov (United States)

    Torricelli, Diego; Cortés, Camilo; Lete, Nerea; Bertelsen, Álvaro; Gonzalez-Vargas, Jose E.; del-Ama, Antonio J.; Dimbwadyo, Iris; Moreno, Juan C.; Florez, Julian; Pons, Jose L.

    2018-01-01

    The relative motion between human and exoskeleton is a crucial factor that has remarkable consequences on the efficiency, reliability and safety of human-robot interaction. Unfortunately, its quantitative assessment has been largely overlooked in the literature. Here, we present a methodology that allows predicting the motion of the human joints from the knowledge of the angular motion of the exoskeleton frame. Our method combines a subject-specific skeletal model with a kinematic model of a lower limb exoskeleton (H2, Technaid), imposing specific kinematic constraints between them. To calibrate the model and validate its ability to predict the relative motion in a subject-specific way, we performed experiments on seven healthy subjects during treadmill walking tasks. We demonstrate a prediction accuracy lower than 3.5° globally, and around 1.5° at the hip level, which represent an improvement up to 66% compared to the traditional approach assuming no relative motion between the user and the exoskeleton. PMID:29755336

  10. Accuracy of human motion capture systems for sport applications; state-of-the-art review.

    Science.gov (United States)

    van der Kruk, Eline; Reijne, Marco M

    2018-05-09

    Sport research often requires human motion capture of an athlete. It can, however, be labour-intensive and difficult to select the right system, while manufacturers report on specifications which are determined in set-ups that largely differ from sport research in terms of volume, environment and motion. The aim of this review is to assist researchers in the selection of a suitable motion capture system for their experimental set-up for sport applications. An open online platform is initiated, to support (sport)researchers in the selection of a system and to enable them to contribute and update the overview. systematic review; Method: Electronic searches in Scopus, Web of Science and Google Scholar were performed, and the reference lists of the screened articles were scrutinised to determine human motion capture systems used in academically published studies on sport analysis. An overview of 17 human motion capture systems is provided, reporting the general specifications given by the manufacturer (weight and size of the sensors, maximum capture volume, environmental feasibilities), and calibration specifications as determined in peer-reviewed studies. The accuracy of each system is plotted against the measurement range. The overview and chart can assist researchers in the selection of a suitable measurement system. To increase the robustness of the database and to keep up with technological developments, we encourage researchers to perform an accuracy test prior to their experiment and to add to the chart and the system overview (online, open access).

  11. The Use of Wearable Inertial Motion Sensors in Human Lower Limb Biomechanics Studies: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Yue-Yan Chan

    2010-12-01

    Full Text Available Wearable motion sensors consisting of accelerometers, gyroscopes and magnetic sensors are readily available nowadays. The small size and low production costs of motion sensors make them a very good tool for human motions analysis. However, data processing and accuracy of the collected data are important issues for research purposes. In this paper, we aim to review the literature related to usage of inertial sensors in human lower limb biomechanics studies. A systematic search was done in the following search engines: ISI Web of Knowledge, Medline, SportDiscus and IEEE Xplore. Thirty nine full papers and conference abstracts with related topics were included in this review. The type of sensor involved, data collection methods, study design, validation methods and its applications were reviewed.

  12. The use of wearable inertial motion sensors in human lower limb biomechanics studies: a systematic review.

    Science.gov (United States)

    Fong, Daniel Tik-Pui; Chan, Yue-Yan

    2010-01-01

    Wearable motion sensors consisting of accelerometers, gyroscopes and magnetic sensors are readily available nowadays. The small size and low production costs of motion sensors make them a very good tool for human motions analysis. However, data processing and accuracy of the collected data are important issues for research purposes. In this paper, we aim to review the literature related to usage of inertial sensors in human lower limb biomechanics studies. A systematic search was done in the following search engines: ISI Web of Knowledge, Medline, SportDiscus and IEEE Xplore. Thirty nine full papers and conference abstracts with related topics were included in this review. The type of sensor involved, data collection methods, study design, validation methods and its applications were reviewed.

  13. Human upper limb manipulator mass center motion and mass moments of inertia variation

    Directory of Open Access Journals (Sweden)

    Nikolova Gergana

    2018-01-01

    Full Text Available Motion control is complicated for people having traumas or neurological diseases. An underlying assumption in our work is that the motion of healthy people is optimal with respect to positioning accuracy, movement response, and energy expenditure. In this paper, a new approach for determination of the human upper limb mass-inertial characteristics is presented by using the 3D geometrical mathematical modeling analysis approach. Two examples will be given to illustrate the main features and advantages of the proposed design concepts. The objective of the work presented in this paper is a determination of the mass properties of a two joints human upper limb manipulator. Results are aimed to have application in an exoskeleton design, the design of manipulation system and external manipulation system, serving people with some motion difficulties, as well as in sport and rehabilitation.

  14. Efficient Human Action and Gait Analysis Using Multiresolution Motion Energy Histogram

    Directory of Open Access Journals (Sweden)

    Kuo-Chin Fan

    2010-01-01

    Full Text Available Average Motion Energy (AME image is a good way to describe human motions. However, it has to face the computation efficiency problem with the increasing number of database templates. In this paper, we propose a histogram-based approach to improve the computation efficiency. We convert the human action/gait recognition problem to a histogram matching problem. In order to speed up the recognition process, we adopt a multiresolution structure on the Motion Energy Histogram (MEH. To utilize the multiresolution structure more efficiently, we propose an automated uneven partitioning method which is achieved by utilizing the quadtree decomposition results of MEH. In that case, the computation time is only relevant to the number of partitioned histogram bins, which is much less than the AME method. Two applications, action recognition and gait classification, are conducted in the experiments to demonstrate the feasibility and validity of the proposed approach.

  15. Analysis of Human's Motions Based on Local Mean Decomposition in Through-wall Radar Detection

    Science.gov (United States)

    Lu, Qi; Liu, Cai; Zeng, Zhaofa; Li, Jing; Zhang, Xuebing

    2016-04-01

    Observation of human motions through a wall is an important issue in security applications and search-and rescue. Radar has advantages in looking through walls where other sensors give low performance or cannot be used at all. Ultrawideband (UWB) radar has high spatial resolution as a result of employment of ultranarrow pulses. It has abilities to distinguish the closely positioned targets and provide time-lapse information of targets. Moreover, the UWB radar shows good performance in wall penetration when the inherently short pulses spread their energy over a broad frequency range. Human's motions show periodic features including respiration, swing arms and legs, fluctuations of the torso. Detection of human targets is based on the fact that there is always periodic motion due to breathing or other body movements like walking. The radar can gain the reflections from each human body parts and add the reflections at each time sample. The periodic movements will cause micro-Doppler modulation in the reflected radar signals. Time-frequency analysis methods are consider as the effective tools to analysis and extract micro-Doppler effects caused by the periodic movements in the reflected radar signal, such as short-time Fourier transform (STFT), wavelet transform (WT), and Hilbert-Huang transform (HHT).The local mean decomposition (LMD), initially developed by Smith (2005), is to decomposed amplitude and frequency modulated signals into a small set of product functions (PFs), each of which is the product of an envelope signal and a frequency modulated signal from which a time-vary instantaneous phase and instantaneous frequency can be derived. As bypassing the Hilbert transform, the LMD has no demodulation error coming from window effect and involves no negative frequency without physical sense. Also, the instantaneous attributes obtained by LMD are more stable and precise than those obtained by the empirical mode decomposition (EMD) because LMD uses smoothed local

  16. Human-like motion planning model for driving in signalized intersections

    Directory of Open Access Journals (Sweden)

    Yanlei Gu

    2017-10-01

    Full Text Available Highly automated and fully autonomous vehicles are much more likely to be accepted if they react in the same way as human drivers do, especially in a hybrid traffic situation, which allows autonomous vehicles and human-driven vehicles to share the same road. This paper proposes a human-like motion planning model to represent how human drivers assess environments and operate vehicles in signalized intersections. The developed model consists of a pedestrian intention detection model, gap detection model, and vehicle control model. These three submodels are individually responsible for situation assessment, decision making, and action, and also depend on each other in the process of motion planning. In addition, these submodels are constructed and learned on the basis of human drivers' data collected from real traffic environments. To verify the effectiveness of the proposed motion planning model, we compared the proposed model with actual human driver and pedestrian data. The experimental results showed that our proposed model and actual human driver behaviors are highly similar with respect to gap acceptance in intersections.

  17. Kinematics design and human motion transfer for a humanoid service robot arm

    CSIR Research Space (South Africa)

    Dube, C

    2009-11-01

    Full Text Available . Philadelphia: Saunders Col- lege Publishing, 1982. [2] Hamill, J. and Knutzen, K. M., Biomechanical Basis of Human Motion, Baltimore: Williams and Wilkins, 1995. [3] Lenarcˇicˇ, J. and Klopcˇar, N.,“Positional kinematics of hu- manoid arms,” Robotica, vol...

  18. Complex Human Activity Recognition Using Smartphone and Wrist-Worn Motion Sensors

    NARCIS (Netherlands)

    Shoaib, M.; Bosch, S.; Durmaz, O.; Scholten, Johan; Havinga, Paul J.M.

    2016-01-01

    The position of on-body motion sensors plays an important role in human activity recognition. Most often, mobile phone sensors at the trouser pocket or an equivalent position are used for this purpose. However, this position is not suitable for recognizing activities that involve hand gestures, such

  19. Human Kinematics of Cochlear Implant Surgery: An Investigation of Insertion Micro-Motions and Speed Limitations.

    Science.gov (United States)

    Kesler, Kyle; Dillon, Neal P; Fichera, Loris; Labadie, Robert F

    2017-09-01

    Objectives Document human motions associated with cochlear implant electrode insertion at different speeds and determine the lower limit of continuous insertion speed by a human. Study Design Observational. Setting Academic medical center. Subjects and Methods Cochlear implant forceps were coupled to a frame containing reflective fiducials, which enabled optical tracking of the forceps' tip position in real time. Otolaryngologists (n = 14) performed mock electrode insertions at different speeds based on recommendations from the literature: "fast" (96 mm/min), "stable" (as slow as possible without stopping), and "slow" (15 mm/min). For each insertion, the following metrics were calculated from the tracked position data: percentage of time at prescribed speed, percentage of time the surgeon stopped moving forward, and number of direction reversals (ie, going from forward to backward motion). Results Fast insertion trials resulted in better adherence to the prescribed speed (45.4% of the overall time), no motion interruptions, and no reversals, as compared with slow insertions (18.6% of time at prescribed speed, 15.7% stopped time, and an average of 18.6 reversals per trial). These differences were statistically significant for all metrics ( P implant electrode at 15 mm/min is not feasible for human operators. The lower limit of continuous forward insertion is 52 mm/min on average. Guidelines on manual insertion kinematics should consider this practical limit of human motion.

  20. One-degree-of-freedom spherical model for the passive motion of the human ankle joint.

    Science.gov (United States)

    Sancisi, Nicola; Baldisserri, Benedetta; Parenti-Castelli, Vincenzo; Belvedere, Claudio; Leardini, Alberto

    2014-04-01

    Mathematical modelling of mobility at the human ankle joint is essential for prosthetics and orthotic design. The scope of this study is to show that the ankle joint passive motion can be represented by a one-degree-of-freedom spherical motion. Moreover, this motion is modelled by a one-degree-of-freedom spherical parallel mechanism model, and the optimal pivot-point position is determined. Passive motion and anatomical data were taken from in vitro experiments in nine lower limb specimens. For each of these, a spherical mechanism, including the tibiofibular and talocalcaneal segments connected by a spherical pair and by the calcaneofibular and tibiocalcaneal ligament links, was defined from the corresponding experimental kinematics and geometry. An iterative procedure was used to optimize the geometry of the model, able to predict original experimental motion. The results of the simulations showed a good replication of the original natural motion, despite the numerous model assumptions and simplifications, with mean differences between experiments and predictions smaller than 1.3 mm (average 0.33 mm) for the three joint position components and smaller than 0.7° (average 0.32°) for the two out-of-sagittal plane rotations, once plotted versus the full flexion arc. The relevant pivot-point position after model optimization was found within the tibial mortise, but not exactly in a central location. The present combined experimental and modelling analysis of passive motion at the human ankle joint shows that a one degree-of-freedom spherical mechanism predicts well what is observed in real joints, although its computational complexity is comparable to the standard hinge joint model.

  1. Cold-induced vasoconstriction at forearm and hand skin sites: the effect of age

    NARCIS (Netherlands)

    Kingma, B.R.M.; Frijns, A.J.H.; Saris, W.H.M.; Steenhoven, van A.A.; Marken Lichtenbelt, van W.D.

    2010-01-01

    During mild cold exposure, elderly are at risk of hypothermia. In humans, glabrous skin at the hands is well adapted as a heat exchanger. Evidence exists that elderly show equal vasoconstriction due to local cooling at the ventral forearm, yet no age effects on vasoconstriction at hand skin have

  2. An examination of the degrees of freedom of human jaw motion in speech and mastication.

    Science.gov (United States)

    Ostry, D J; Vatikiotis-Bateson, E; Gribble, P L

    1997-12-01

    The kinematics of human jaw movements were assessed in terms of the three orientation angles and three positions that characterize the motion of the jaw as a rigid body. The analysis focused on the identification of the jaw's independent movement dimensions, and was based on an examination of jaw motion paths that were plotted in various combinations of linear and angular coordinate frames. Overall, both behaviors were characterized by independent motion in four degrees of freedom. In general, when jaw movements were plotted to show orientation in the sagittal plane as a function of horizontal position, relatively straight paths were observed. In speech, the slopes and intercepts of these paths varied depending on the phonetic material. The vertical position of the jaw was observed to shift up or down so as to displace the overall form of the sagittal plane motion path of the jaw. Yaw movements were small but independent of pitch, and vertical and horizontal position. In mastication, the slope and intercept of the relationship between pitch and horizontal position were affected by the type of food and its size. However, the range of variation was less than that observed in speech. When vertical jaw position was plotted as a function of horizontal position, the basic form of the path of the jaw was maintained but could be shifted vertically. In general, larger bolus diameters were associated with lower jaw positions throughout the movement. The timing of pitch and yaw motion differed. The most common pattern involved changes in pitch angle during jaw opening followed by a phase predominated by lateral motion (yaw). Thus, in both behaviors there was evidence of independent motion in pitch, yaw, horizontal position, and vertical position. This is consistent with the idea that motions in these degrees of freedom are independently controlled.

  3. Application Of Three-Dimensional Videography To Human Motion Studies: Constraints, Assumptions, And Mathematics

    Science.gov (United States)

    Rab, George T.

    1988-02-01

    Three-dimensional human motion analysis has been used for complex kinematic description of abnormal gait in children with neuromuscular disease. Multiple skin markers estimate skeletal segment position, and a sorting and smoothing routine provides marker trajectories. The position and orientation of the moving skeleton in space are derived mathematically from the marker positions, and joint motions are calculated from the Eulerian transformation matrix between linked proximal and distal skeletal segments. Reproduceability has been excellent, and the technique has proven to be a useful adjunct to surgical planning.

  4. Testing human sperm chemotaxis: how to detect biased motion in population assays.

    Directory of Open Access Journals (Sweden)

    Leah Armon

    Full Text Available Biased motion of motile cells in a concentration gradient of a chemoattractant is frequently studied on the population level. This approach has been particularly employed in human sperm chemotactic assays, where the fraction of responsive cells is low and detection of biased motion depends on subtle differences. In these assays, statistical measures such as population odds ratios of swimming directions can be employed to infer chemotactic performance. Here, we report on an improved method to assess statistical significance of experimentally determined odds ratios and discuss the strong impact of data correlations that arise from the directional persistence of sperm swimming.

  5. Spatio-Temporal Constrained Human Trajectory Generation from the PIR Motion Detector Sensor Network Data: A Geometric Algebra Approach.

    Science.gov (United States)

    Yu, Zhaoyuan; Yuan, Linwang; Luo, Wen; Feng, Linyao; Lv, Guonian

    2015-12-30

    Passive infrared (PIR) motion detectors, which can support long-term continuous observation, are widely used for human motion analysis. Extracting all possible trajectories from the PIR sensor networks is important. Because the PIR sensor does not log location and individual information, none of the existing methods can generate all possible human motion trajectories that satisfy various spatio-temporal constraints from the sensor activation log data. In this paper, a geometric algebra (GA)-based approach is developed to generate all possible human trajectories from the PIR sensor network data. Firstly, the representation of the geographical network, sensor activation response sequences and the human motion are represented as algebraic elements using GA. The human motion status of each sensor activation are labeled using the GA-based trajectory tracking. Then, a matrix multiplication approach is developed to dynamically generate the human trajectories according to the sensor activation log and the spatio-temporal constraints. The method is tested with the MERL motion database. Experiments show that our method can flexibly extract the major statistical pattern of the human motion. Compared with direct statistical analysis and tracklet graph method, our method can effectively extract all possible trajectories of the human motion, which makes it more accurate. Our method is also likely to provides a new way to filter other passive sensor log data in sensor networks.

  6. Spatio-Temporal Constrained Human Trajectory Generation from the PIR Motion Detector Sensor Network Data: A Geometric Algebra Approach

    Directory of Open Access Journals (Sweden)

    Zhaoyuan Yu

    2015-12-01

    Full Text Available Passive infrared (PIR motion detectors, which can support long-term continuous observation, are widely used for human motion analysis. Extracting all possible trajectories from the PIR sensor networks is important. Because the PIR sensor does not log location and individual information, none of the existing methods can generate all possible human motion trajectories that satisfy various spatio-temporal constraints from the sensor activation log data. In this paper, a geometric algebra (GA-based approach is developed to generate all possible human trajectories from the PIR sensor network data. Firstly, the representation of the geographical network, sensor activation response sequences and the human motion are represented as algebraic elements using GA. The human motion status of each sensor activation are labeled using the GA-based trajectory tracking. Then, a matrix multiplication approach is developed to dynamically generate the human trajectories according to the sensor activation log and the spatio-temporal constraints. The method is tested with the MERL motion database. Experiments show that our method can flexibly extract the major statistical pattern of the human motion. Compared with direct statistical analysis and tracklet graph method, our method can effectively extract all possible trajectories of the human motion, which makes it more accurate. Our method is also likely to provides a new way to filter other passive sensor log data in sensor networks.

  7. Familial aggregation of forearm bone mineral density in Chinese

    International Nuclear Information System (INIS)

    Hong Xiumei; Niu Tianhua; Chen Changzhong; Wang Binyan; Venners, Scott A.; Fang Zhian; Xu Xiping

    2007-01-01

    Osteoporosis is a major public health concern and its prevalence can be predicted based on forearm bone mineral density (BMD). This study is to investigate the familial aggregation of forearm BMD in a population-based, cross-sectional study in Anhui, China. Information on sociodemographic and environmental variables was obtained from 1,636 subjects from 409 nuclear families (including mother, father, and their first two children) by a standardized questionnaire. The forearm BMD was measured by peripheral dual-energy X-ray absorptiometry (pDXA). Using generalized additive models with a sequential adjustment for covariates, it was clearly indicated that the forearm BMD of the mother, the father, and the first sibling each had a significant and independent relation to the forearm BMD of the second sibling. Furthermore, using multiple logistic regression, the second sibling had an odds ratio (OR) of 5.3 (95%CI: 2.0-14.5) of having an extremely low (bottom 10th percentile) proximal forearm BMD and an OR of 4.3 (95%CI: 1.6-12.0) of having an extremely low distal forearm BMD when the parental mean forearm BMD was low and the first sibling's forearm BMD was low. Our findings showing strong familial aggregation of both proximal and distal forearm BMD values suggest that genetic factors play a significant role in determining both traits

  8. Dynamics Of Human Motion The Case Study of an Examination Hall

    Science.gov (United States)

    Ogunjo, Samuel; Ajayi, Oluwaseyi; Fuwape, Ibiyinka; Dansu, Emmanuel

    Human behaviour is difficult to characterize and generalize due to ITS complex nature. Advances in mathematical models have enabled human systems such as love interaction, alcohol abuse, admission problem to be described using models. This study investigates one of such problems, the dynamics of human motion in an examination hall with limited computer systems such that students write their examination in batches. The examination is characterized by time (t) allocated to each students and difficulty level (dl) associated with the examination. A stochastic model based on the difficulty level of the examination was developed for the prediction of student's motion around the examination hall. A good agreement was obtained between theoretical predictions and numerical simulation. The result obtained will help in better planning of examination session to maximize available resources. Furthermore, results obtained in the research can be extended to other areas such as banking hall, customer service points where available resources will be shared amongst many users.

  9. Energy Harvesting from Upper-Limb Pulling Motions for Miniaturized Human-Powered Generators.

    Science.gov (United States)

    Yeo, Jeongjin; Ryu, Mun-ho; Yang, Yoonseok

    2015-07-03

    The human-powered self-generator provides the best solution for individuals who need an instantaneous power supply for travel, outdoor, and emergency use, since it is less dependent on weather conditions and occupies less space than other renewable power supplies. However, many commercial portable self-generators that employ hand-cranking are not used as much as expected in daily lives although they have enough output capacity due to their intensive workload. This study proposes a portable human-powered generator which is designed to obtain mechanical energy from an upper limb pulling motion for improved human motion economy as well as efficient human-mechanical power transfer. A coreless axial-flux permanent magnet machine (APMM) and a flywheel magnet rotor were used in conjunction with a one-way clutched power transmission system in order to obtain effective power from the pulling motion. The developed prototype showed an average energy conversion efficiency of 30.98% and an average output power of 0.32 W with a maximum of 1.89 W. Its small form factor (50 mm × 32 mm × 43.5 mm, 0.05 kg) and the substantial electricity produced verify the effectiveness of the proposed method in the utilization of human power. It is expected that the developed generator could provide a mobile power supply.

  10. Energy Harvesting from Upper-Limb Pulling Motions for Miniaturized Human-Powered Generators

    Directory of Open Access Journals (Sweden)

    Jeongjin Yeo

    2015-07-01

    Full Text Available The human-powered self-generator provides the best solution for individuals who need an instantaneous power supply for travel, outdoor, and emergency use, since it is less dependent on weather conditions and occupies less space than other renewable power supplies. However, many commercial portable self-generators that employ hand-cranking are not used as much as expected in daily lives although they have enough output capacity due to their intensive workload. This study proposes a portable human-powered generator which is designed to obtain mechanical energy from an upper limb pulling motion for improved human motion economy as well as efficient human-mechanical power transfer. A coreless axial-flux permanent magnet machine (APMM and a flywheel magnet rotor were used in conjunction with a one-way clutched power transmission system in order to obtain effective power from the pulling motion. The developed prototype showed an average energy conversion efficiency of 30.98% and an average output power of 0.32 W with a maximum of 1.89 W. Its small form factor (50 mm × 32 mm × 43.5 mm, 0.05 kg and the substantial electricity produced verify the effectiveness of the proposed method in the utilization of human power. It is expected that the developed generator could provide a mobile power supply.

  11. Observation and analysis of high-speed human motion with frequent occlusion in a large area

    International Nuclear Information System (INIS)

    Wang, Yuru; Liu, Jiafeng; Liu, Guojun; Tang, Xianglong; Liu, Peng

    2009-01-01

    The use of computer vision technology in collecting and analyzing statistics during sports matches or training sessions is expected to provide valuable information for tactics improvement. However, the measurements published in the literature so far are either unreliably documented to be used in training planning due to their limitations or unsuitable for studying high-speed motion in large area with frequent occlusions. A sports annotation system is introduced in this paper for tracking high-speed non-rigid human motion over a large playing area with the aid of motion camera, taking short track speed skating competitions as an example. The proposed system is composed of two sub-systems: precise camera motion compensation and accurate motion acquisition. In the video registration step, a distinctive invariant point feature detector (probability density grads detector) and a global parallax based matching points filter are used, to provide reliable and robust matching across a large range of affine distortion and illumination change. In the motion acquisition step, a two regions' relationship constrained joint color model and Markov chain Monte Carlo based joint particle filter are emphasized, by dividing the human body into two relative key regions. Several field tests are performed to assess measurement errors, including comparison to popular algorithms. With the help of the system presented, the system obtains position data on a 30 m × 60 m large rink with root-mean-square error better than 0.3975 m, velocity and acceleration data with absolute error better than 1.2579 m s −1 and 0.1494 m s −2 , respectively

  12. Observation and analysis of high-speed human motion with frequent occlusion in a large area

    Science.gov (United States)

    Wang, Yuru; Liu, Jiafeng; Liu, Guojun; Tang, Xianglong; Liu, Peng

    2009-12-01

    The use of computer vision technology in collecting and analyzing statistics during sports matches or training sessions is expected to provide valuable information for tactics improvement. However, the measurements published in the literature so far are either unreliably documented to be used in training planning due to their limitations or unsuitable for studying high-speed motion in large area with frequent occlusions. A sports annotation system is introduced in this paper for tracking high-speed non-rigid human motion over a large playing area with the aid of motion camera, taking short track speed skating competitions as an example. The proposed system is composed of two sub-systems: precise camera motion compensation and accurate motion acquisition. In the video registration step, a distinctive invariant point feature detector (probability density grads detector) and a global parallax based matching points filter are used, to provide reliable and robust matching across a large range of affine distortion and illumination change. In the motion acquisition step, a two regions' relationship constrained joint color model and Markov chain Monte Carlo based joint particle filter are emphasized, by dividing the human body into two relative key regions. Several field tests are performed to assess measurement errors, including comparison to popular algorithms. With the help of the system presented, the system obtains position data on a 30 m × 60 m large rink with root-mean-square error better than 0.3975 m, velocity and acceleration data with absolute error better than 1.2579 m s-1 and 0.1494 m s-2, respectively.

  13. Supinator Extender (SUE): a pneumatically actuated robot for forearm/wrist rehabilitation after stroke.

    Science.gov (United States)

    Allington, James; Spencer, Steven J; Klein, Julius; Buell, Meghan; Reinkensmeyer, David J; Bobrow, James

    2011-01-01

    The robot described in this paper, SUE (Supinator Extender), adds forearm/wrist rehabilitation functionality to the UCI BONES exoskeleton robot and to the ArmeoSpring rehabilitation device. SUE is a 2-DOF serial chain that can measure and assist forearm supination-pronation and wrist flexion-extension. The large power to weight ratio of pneumatic actuators allows SUE to achieve the forces needed for rehabilitation therapy while remaining lightweight enough to be carried by BONES and ArmeoSpring. Each degree of freedom has a range of 90 degrees, and a nominal torque of 2 ft-lbs. The cylinders are mounted away from the patient's body on the lateral aspect of the arm. This is to prevent the danger of a collision and maximize the workspace of the arm robot. The rotation axis used for supination-pronation is a small bearing just below the subject's wrist. The flexion-extension motion is actuated by a cantilevered pneumatic cylinder, which allows the palm of the hand to remain open. Data are presented that demonstrate the ability of SUE to measure and cancel forearm/wrist passive tone, thereby extending the active range of motion for people with stroke.

  14. The forearm complex: anatomy, biomechanics and clinical considerations.

    Science.gov (United States)

    LaStayo, Paul C; Lee, Michael J

    2006-01-01

    The forearm complex is comprised of the proximal radioulnar joint, middle radioulnar joint/interosseous membrane, and the distal radioulnar joint. These three areas function in a coordinated manner to rotate the hand in space and allow performance of functional tasks. If a structure or structures in one of these three areas is disrupted, this can adversely affect the function at any of the other two remaining areas. Surgical intervention focuses on restoring anatomical alignment to preserve the function of the forearm complex. Rehabilitation is guided by the relationships between the three areas of the forearm complex and the awareness of clinical signs, symptoms, and complications. The purposes of this paper are to 1) describe the anatomy and biomechanical function of the forearm complex and 2) discuss clinical correlates pertaining to select forearm injuries (excluding peripheral nerve injuries) that may affect forearm function.

  15. Human Classification Based on Gestural Motions by Using Components of PCA

    International Nuclear Information System (INIS)

    Aziz, Azri A; Wan, Khairunizam; Za'aba, S K; Shahriman A B; Asyekin H; Zuradzman M R; Adnan, Nazrul H

    2013-01-01

    Lately, a study of human capabilities with the aim to be integrated into machine is the famous topic to be discussed. Moreover, human are bless with special abilities that they can hear, see, sense, speak, think and understand each other. Giving such abilities to machine for improvement of human life is researcher's aim for better quality of life in the future. This research was concentrating on human gesture, specifically arm motions for differencing the individuality which lead to the development of the hand gesture database. We try to differentiate the human physical characteristic based on hand gesture represented by arm trajectories. Subjects are selected from different type of the body sizes, and then acquired data undergo resampling process. The results discuss the classification of human based on arm trajectories by using Principle Component Analysis (PCA)

  16. Self-adapted and tunable graphene strain sensors for detecting both subtle and large human motions.

    Science.gov (United States)

    Tao, Lu-Qi; Wang, Dan-Yang; Tian, He; Ju, Zhen-Yi; Liu, Ying; Pang, Yu; Chen, Yuan-Quan; Yang, Yi; Ren, Tian-Ling

    2017-06-22

    Conventional strain sensors rarely have both a high gauge factor and a large strain range simultaneously, so they can only be used in specific situations where only a high sensitivity or a large strain range is required. However, for detecting human motions that include both subtle and large motions, these strain sensors can't meet the diverse demands simultaneously. Here, we come up with laser patterned graphene strain sensors with self-adapted and tunable performance for the first time. A series of strain sensors with either an ultrahigh gauge factor or a preferable strain range can be fabricated simultaneously via one-step laser patterning, and are suitable for detecting all human motions. The strain sensors have a GF of up to 457 with a strain range of 35%, or have a strain range of up to 100% with a GF of 268. Most importantly, the performance of the strain sensors can be easily tuned by adjusting the patterns of the graphene, so that the sensors can meet diverse demands in both subtle and large motion situations. The graphene strain sensors show significant potential in applications such as wearable electronics, health monitoring and intelligent robots. Furthermore, the facile, fast and low-cost fabrication method will make them possible and practical to be used for commercial applications in the future.

  17. Ambiguity in Tactile Apparent Motion Perception.

    Directory of Open Access Journals (Sweden)

    Emanuela Liaci

    Full Text Available In von Schiller's Stroboscopic Alternative Motion (SAM stimulus two visually presented diagonal dot pairs, located on the corners of an imaginary rectangle, alternate with each other and induce either horizontal, vertical or, rarely, rotational motion percepts. SAM motion perception can be described by a psychometric function of the dot aspect ratio ("AR", i.e. the relation between vertical and horizontal dot distances. Further, with equal horizontal and vertical dot distances (AR = 1 perception is biased towards vertical motion. In a series of five experiments, we presented tactile SAM versions and studied the role of AR and of different reference frames for the perception of tactile apparent motion.We presented tactile SAM stimuli and varied the ARs, while participants reported the perceived motion directions. Pairs of vibration stimulators were attached to the participants' forearms and stimulator distances were varied within and between forearms. We compared straight and rotated forearm conditions with each other in order to disentangle the roles of exogenous and endogenous reference frames.Increasing the tactile SAM's AR biased perception towards vertical motion, but the effect was weak compared to the visual modality. We found no horizontal disambiguation, even for very small tactile ARs. A forearm rotation by 90° kept the vertical bias, even though it was now coupled with small ARs. A 45° rotation condition with crossed forearms, however, evoked a strong horizontal motion bias.Existing approaches to explain the visual SAM bias fail to explain the current tactile results. Particularly puzzling is the strong horizontal bias in the crossed-forearm conditions. In the case of tactile apparent motion, there seem to be no fixed priority rule for perceptual disambiguation. Rather the weighting of available evidence seems to depend on the degree of stimulus ambiguity, the current situation and on the perceptual strategy of the individual

  18. Open Fracture of the Forearm Bones due to Horse Bite

    OpenAIRE

    Santoshi, John Ashutosh; Leshem, Lall

    2014-01-01

    Introduction: Fractures have been described mainly following falling accidents in horse-related injuries. Horse bites are uncommon accidents. We present a case of open fracture of the forearm due to horse bite. Case Report: A 35-year-old male farm-worker presented to the emergency room with alleged history of horse bite to the right forearm about 2 hours prior to presentation while feeding the horse. There was deformity of the forearm with multiple puncture wounds, deep abrasions and small...

  19. Mechanical design of EFW Exo II: A hybrid exoskeleton for elbow-forearm-wrist rehabilitation.

    Science.gov (United States)

    Bian, Hui; Chen, Ziye; Wang, Hao; Zhao, Tieshi

    2017-07-01

    The use of rehabilitation exoskeleton has become an important means for the treatment of stroke patients. A hybrid exoskeleton named EFW Exo II is developed for the motor function rehabilitation of elbow, forearm and wrist. The EFW Exo II is based on a parallel 2-URR/RRS mechanism and a serial R mechanism. It could fit both left and right arms for the symmetrical and open structure, and the distance between the elbow and wrist could automatically adjust for different forearm length. Details of the mechanical design are introduced. Brushless DC servo motors with planetary gear reducer are used as the actuators of the exoskeleton. Gear drive and belt drive are used for power transmission. A three dimensional force sensor is mounted in the handle to regulate the interaction between the exoskeleton and patient. The EFW Exo II can realize rehabilitation exercise for each joint and the ranges of motion meet the rehabilitation demands of daily living.

  20. Biomechanical energy harvesting from human motion: theory, state of the art, design guidelines, and future directions.

    Science.gov (United States)

    Riemer, Raziel; Shapiro, Amir

    2011-04-26

    Biomechanical energy harvesting from human motion presents a promising clean alternative to electrical power supplied by batteries for portable electronic devices and for computerized and motorized prosthetics. We present the theory of energy harvesting from the human body and describe the amount of energy that can be harvested from body heat and from motions of various parts of the body during walking, such as heel strike; ankle, knee, hip, shoulder, and elbow joint motion; and center of mass vertical motion. We evaluated major motions performed during walking and identified the amount of work the body expends and the portion of recoverable energy. During walking, there are phases of the motion at the joints where muscles act as brakes and energy is lost to the surroundings. During those phases of motion, the required braking force or torque can be replaced by an electrical generator, allowing energy to be harvested at the cost of only minimal additional effort. The amount of energy that can be harvested was estimated experimentally and from literature data. Recommendations for future directions are made on the basis of our results in combination with a review of state-of-the-art biomechanical energy harvesting devices and energy conversion methods. For a device that uses center of mass motion, the maximum amount of energy that can be harvested is approximately 1 W per kilogram of device weight. For a person weighing 80 kg and walking at approximately 4 km/h, the power generation from the heel strike is approximately 2 W. For a joint-mounted device based on generative braking, the joints generating the most power are the knees (34 W) and the ankles (20 W). Our theoretical calculations align well with current device performance data. Our results suggest that the most energy can be harvested from the lower limb joints, but to do so efficiently, an innovative and light-weight mechanical design is needed. We also compared the option of carrying batteries to the

  1. Using Fuzzy Gaussian Inference and Genetic Programming to Classify 3D Human Motions

    Science.gov (United States)

    Khoury, Mehdi; Liu, Honghai

    This research introduces and builds on the concept of Fuzzy Gaussian Inference (FGI) (Khoury and Liu in Proceedings of UKCI, 2008 and IEEE Workshop on Robotic Intelligence in Informationally Structured Space (RiiSS 2009), 2009) as a novel way to build Fuzzy Membership Functions that map to hidden Probability Distributions underlying human motions. This method is now combined with a Genetic Programming Fuzzy rule-based system in order to classify boxing moves from natural human Motion Capture data. In this experiment, FGI alone is able to recognise seven different boxing stances simultaneously with an accuracy superior to a GMM-based classifier. Results seem to indicate that adding an evolutionary Fuzzy Inference Engine on top of FGI improves the accuracy of the classifier in a consistent way.

  2. Visual motion transforms visual space representations similarly throughout the human visual hierarchy.

    Science.gov (United States)

    Harvey, Ben M; Dumoulin, Serge O

    2016-02-15

    Several studies demonstrate that visual stimulus motion affects neural receptive fields and fMRI response amplitudes. Here we unite results of these two approaches and extend them by examining the effects of visual motion on neural position preferences throughout the hierarchy of human visual field maps. We measured population receptive field (pRF) properties using high-field fMRI (7T), characterizing position preferences simultaneously over large regions of the visual cortex. We measured pRFs properties using sine wave gratings in stationary apertures, moving at various speeds in either the direction of pRF measurement or the orthogonal direction. We find direction- and speed-dependent changes in pRF preferred position and size in all visual field maps examined, including V1, V3A, and the MT+ map TO1. These effects on pRF properties increase up the hierarchy of visual field maps. However, both within and between visual field maps the extent of pRF changes was approximately proportional to pRF size. This suggests that visual motion transforms the representation of visual space similarly throughout the visual hierarchy. Visual motion can also produce an illusory displacement of perceived stimulus position. We demonstrate perceptual displacements using the same stimulus configuration. In contrast to effects on pRF properties, perceptual displacements show only weak effects of motion speed, with far larger speed-independent effects. We describe a model where low-level mechanisms could underlie the observed effects on neural position preferences. We conclude that visual motion induces similar transformations of visuo-spatial representations throughout the visual hierarchy, which may arise through low-level mechanisms. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Flexible and multi-directional piezoelectric energy harvester for self-powered human motion sensor

    Science.gov (United States)

    Kim, Min-Ook; Pyo, Soonjae; Oh, Yongkeun; Kang, Yunsung; Cho, Kyung-Ho; Choi, Jungwook; Kim, Jongbaeg

    2018-03-01

    A flexible piezoelectric strain energy harvester that is responsive to multi-directional input forces produced by various human motions is proposed. The structure of the harvester, which includes a polydimethylsiloxane (PDMS) bump, facilitates the effective conversion of strain energy, produced by input forces applied in random directions, into electrical energy. The structural design of the PDMS bump and frame as well as the slits in the piezoelectric polyvinylidene fluoride (PVDF) film provide mechanical flexibility and enhance the strain induced in the PVDF film under input forces applied at various angles. The amount and direction of the strain induced in PVDF can be changed by the direction of the applied force; thus, the generated output power can be varied. The measured maximum output peak voltage is 1.75, 1.29, and 0.98 V when an input force of 4 N (2 Hz) is applied at angles of 0°, 45°, and 90°, and the corresponding maximum output power is 0.064, 0.026, and 0.02 μW, respectively. Moreover, the harvester stably generates output voltage over 1.4 × 104 cycles. Thus, the proposed harvester successfully identifies and converts strain energy produced by multi-directional input forces by various human motions into electrical energy. We demonstrate the potential utility of the proposed flexible energy harvester as a self-powered human motion sensor for wireless healthcare systems.

  4. Frequency of gamma oscillations in humans is modulated by velocity of visual motion

    Science.gov (United States)

    Butorina, Anna V.; Sysoeva, Olga V.; Prokofyev, Andrey O.; Nikolaeva, Anastasia Yu.; Stroganova, Tatiana A.

    2015-01-01

    Gamma oscillations are generated in networks of inhibitory fast-spiking (FS) parvalbumin-positive (PV) interneurons and pyramidal cells. In animals, gamma frequency is modulated by the velocity of visual motion; the effect of velocity has not been evaluated in humans. In this work, we have studied velocity-related modulations of gamma frequency in children using MEG/EEG. We also investigated whether such modulations predict the prominence of the “spatial suppression” effect (Tadin D, Lappin JS, Gilroy LA, Blake R. Nature 424: 312-315, 2003) that is thought to depend on cortical center-surround inhibitory mechanisms. MEG/EEG was recorded in 27 normal boys aged 8–15 yr while they watched high-contrast black-and-white annular gratings drifting with velocities of 1.2, 3.6, and 6.0°/s and performed a simple detection task. The spatial suppression effect was assessed in a separate psychophysical experiment. MEG gamma oscillation frequency increased while power decreased with increasing velocity of visual motion. In EEG, the effects were less reliable. The frequencies of the velocity-specific gamma peaks were 64.9, 74.8, and 87.1 Hz for the slow, medium, and fast motions, respectively. The frequency of the gamma response elicited during slow and medium velocity of visual motion decreased with subject age, whereas the range of gamma frequency modulation by velocity increased with age. The frequency modulation range predicted spatial suppression even after controlling for the effect of age. We suggest that the modulation of the MEG gamma frequency by velocity of visual motion reflects excitability of cortical inhibitory circuits and can be used to investigate their normal and pathological development in the human brain. PMID:25925324

  5. Combination of Accumulated Motion and Color Segmentation for Human Activity Analysis

    Directory of Open Access Journals (Sweden)

    Briassouli Alexia

    2008-01-01

    Full Text Available Abstract The automated analysis of activity in digital multimedia, and especially video, is gaining more and more importance due to the evolution of higher-level video processing systems and the development of relevant applications such as surveillance and sports. This paper presents a novel algorithm for the recognition and classification of human activities, which employs motion and color characteristics in a complementary manner, so as to extract the most information from both sources, and overcome their individual limitations. The proposed method accumulates the flow estimates in a video, and extracts "regions of activity" by processing their higher-order statistics. The shape of these activity areas can be used for the classification of the human activities and events taking place in a video and the subsequent extraction of higher-level semantics. Color segmentation of the active and static areas of each video frame is performed to complement this information. The color layers in the activity and background areas are compared using the earth mover's distance, in order to achieve accurate object segmentation. Thus, unlike much existing work on human activity analysis, the proposed approach is based on general color and motion processing methods, and not on specific models of the human body and its kinematics. The combined use of color and motion information increases the method robustness to illumination variations and measurement noise. Consequently, the proposed approach can lead to higher-level information about human activities, but its applicability is not limited to specific human actions. We present experiments with various real video sequences, from sports and surveillance domains, to demonstrate the effectiveness of our approach.

  6. Combination of Accumulated Motion and Color Segmentation for Human Activity Analysis

    Directory of Open Access Journals (Sweden)

    Ioannis Kompatsiaris

    2008-03-01

    Full Text Available The automated analysis of activity in digital multimedia, and especially video, is gaining more and more importance due to the evolution of higher-level video processing systems and the development of relevant applications such as surveillance and sports. This paper presents a novel algorithm for the recognition and classification of human activities, which employs motion and color characteristics in a complementary manner, so as to extract the most information from both sources, and overcome their individual limitations. The proposed method accumulates the flow estimates in a video, and extracts “regions of activity” by processing their higher-order statistics. The shape of these activity areas can be used for the classification of the human activities and events taking place in a video and the subsequent extraction of higher-level semantics. Color segmentation of the active and static areas of each video frame is performed to complement this information. The color layers in the activity and background areas are compared using the earth mover's distance, in order to achieve accurate object segmentation. Thus, unlike much existing work on human activity analysis, the proposed approach is based on general color and motion processing methods, and not on specific models of the human body and its kinematics. The combined use of color and motion information increases the method robustness to illumination variations and measurement noise. Consequently, the proposed approach can lead to higher-level information about human activities, but its applicability is not limited to specific human actions. We present experiments with various real video sequences, from sports and surveillance domains, to demonstrate the effectiveness of our approach.

  7. Compression of Human Motion Animation Using the Reduction of Interjoint Correlation

    Directory of Open Access Journals (Sweden)

    Shiyu Li

    2008-01-01

    Full Text Available We propose two compression methods for the human motion in 3D space, based on the forward and inverse kinematics. In a motion chain, a movement of each joint is represented by a series of vector signals in 3D space. In general, specific types of joints such as end effectors often require higher precision than other general types of joints in, for example, CG animation and robot manipulation. The first method, which combines wavelet transform and forward kinematics, enables users to reconstruct the end effectors more precisely. Moreover, progressive decoding can be realized. The distortion of parent joint coming from quantization affects its child joint in turn and is accumulated to the end effector. To address this problem and to control the movement of the whole body, we propose a prediction method further based on the inverse kinematics. This method achieves efficient compression with a higher compression ratio and higher quality of the motion data. By comparing with some conventional methods, we demonstrate the advantage of ours with typical motions.

  8. Compression of Human Motion Animation Using the Reduction of Interjoint Correlation

    Directory of Open Access Journals (Sweden)

    Li Shiyu

    2008-01-01

    Full Text Available Abstract We propose two compression methods for the human motion in 3D space, based on the forward and inverse kinematics. In a motion chain, a movement of each joint is represented by a series of vector signals in 3D space. In general, specific types of joints such as end effectors often require higher precision than other general types of joints in, for example, CG animation and robot manipulation. The first method, which combines wavelet transform and forward kinematics, enables users to reconstruct the end effectors more precisely. Moreover, progressive decoding can be realized. The distortion of parent joint coming from quantization affects its child joint in turn and is accumulated to the end effector. To address this problem and to control the movement of the whole body, we propose a prediction method further based on the inverse kinematics. This method achieves efficient compression with a higher compression ratio and higher quality of the motion data. By comparing with some conventional methods, we demonstrate the advantage of ours with typical motions.

  9. Neural Integration of Information Specifying Human Structure from Form, Motion, and Depth

    Science.gov (United States)

    Jackson, Stuart; Blake, Randolph

    2010-01-01

    Recent computational models of biological motion perception operate on ambiguous two-dimensional representations of the body (e.g., snapshots, posture templates) and contain no explicit means for disambiguating the three-dimensional orientation of a perceived human figure. Are there neural mechanisms in the visual system that represent a moving human figure’s orientation in three dimensions? To isolate and characterize the neural mechanisms mediating perception of biological motion, we used an adaptation paradigm together with bistable point-light (PL) animations whose perceived direction of heading fluctuates over time. After exposure to a PL walker with a particular stereoscopically defined heading direction, observers experienced a consistent aftereffect: a bistable PL walker, which could be perceived in the adapted orientation or reversed in depth, was perceived predominantly reversed in depth. A phase-scrambled adaptor produced no aftereffect, yet when adapting and test walkers differed in size or appeared on opposite sides of fixation aftereffects did occur. Thus, this heading direction aftereffect cannot be explained by local, disparity-specific motion adaptation, and the properties of scale and position invariance imply higher-level origins of neural adaptation. Nor is disparity essential for producing adaptation: when suspended on top of a stereoscopically defined, rotating globe, a context-disambiguated “globetrotter” was sufficient to bias the bistable walker’s direction, as were full-body adaptors. In sum, these results imply that the neural signals supporting biomotion perception integrate information on the form, motion, and three-dimensional depth orientation of the moving human figure. Models of biomotion perception should incorporate mechanisms to disambiguate depth ambiguities in two-dimensional body representations. PMID:20089892

  10. Cold-induced vasoconstriction at forearm and hand skin sites: the effect of age.

    Science.gov (United States)

    Kingma, B R M; Frijns, A J H; Saris, W H M; van Steenhoven, A A; van Marken Lichtenbelt, W D

    2010-07-01

    During mild cold exposure, elderly are at risk of hypothermia. In humans, glabrous skin at the hands is well adapted as a heat exchanger. Evidence exists that elderly show equal vasoconstriction due to local cooling at the ventral forearm, yet no age effects on vasoconstriction at hand skin have been studied. Here, we tested the hypotheses that at hand sites (a) elderly show equal vasoconstriction due to local cooling and (b) elderly show reduced response to noradrenergic stimuli. Skin perfusion and mean arterial pressure were measured in 16 young adults (Y: 18-28 years) and 16 elderly (E: 68-78 years). To study the effect of local vasoconstriction mechanisms local sympathetic nerve terminals were blocked by bretylium (BR). Baseline local skin temperature was clamped at 33 degrees C. Next, local temperature was reduced to 24 degrees C. After 15 min of local cooling, noradrenaline (NA) was administered to study the effect of neural vasoconstriction mechanisms. No significant age effect was observed in vasoconstriction due to local cooling at BR sites. After NA, vasoconstriction at the forearm showed a significant age effect; however, no significant age effect was found at the hand sites. [Change in CVC (% from baseline): Forearm Y: -76 +/- 3 vs. E: -60 +/- 5 (P forearm, elderly did not show a blunted response to local cooling and noradrenaline at hand skin sites. This indicates that at hand skin the noradrenergic mechanism of vasoconstriction is maintained with age.

  11. Robotic Assistance of Human Motion Using Active-Backdrivability on a Geared Electromagnetic Motor

    Directory of Open Access Journals (Sweden)

    Mario Jorge Claros

    2016-03-01

    Full Text Available In this research, we describe an actuation and control system designed for geared electromagnetic motors, which is characterized by its simple implementation, fast response to external input loads, reliable human-machine interaction features, no need for previous set-up or calibration from user to user and high portability due to the reduction of weight and space used. By the implementation of the proposed system, an electromagnetic motor can become a multitasking, wearable actuation system capable of: detecting the user's intentions regarding motion, tracking the limbs with minimal force interaction within a wide bandwidth and also providing controllable assistance and resistance forces to the user's movements, without the use of any biological signal. Validation of the proposed approach is shown by the construction of a powered orthosis for the knee, used to test the system's performance under real human motion conditions. The proposed system was tested on one healthy subject by measuring electromyographic levels both with and without the orthosis, under controlled flexion and extension cycles. Experimental results demonstrate the effectiveness of the proposed approach in detecting the user's intentions regarding motion, reducing and increasing muscular activity when configured for assistance and resistance, respectively, and also increasing the transparency of the actuation system when perfect tracking of the limbs is needed.

  12. Bone mineral content of the forearm in healthy Dutch women

    NARCIS (Netherlands)

    Barentsen, R.; Raymakers, J.A.; Landman, J.O.; Duursma, S.A.

    1988-01-01

    Single energy photon absorptiometry is a reliable technique for assessing the bone mineral content (BMC) of cortical bone in the forearm. It can also be used for BMC measurement in the ultradistal part of the forearm, where there is a considerable proportion of trabecular bone. The results of a BMC

  13. Teaching Strategies for the Forearm Pass in Volleyball

    Science.gov (United States)

    Casebolt, Kevin; Zhang, Peng; Brett, Christine

    2014-01-01

    This article shares teaching strategies for the forearm pass in the game of volleyball and identifies how they will help students improve their performance and development of forearm passing skills. The article also provides an assessment rubric to facilitate student understanding of the skill.

  14. Flexor digitorum profundus tendon anatomy in the forearm

    Directory of Open Access Journals (Sweden)

    Teoman Dogan

    2012-04-01

    Methods: We used 11 forearms belonging to cadavers and fixed with formaldehyde. The forearms numbered 1, 2, 8, 9, 10, 11 were the left and right arms of the same cadavers. Those numbered 3, 4, 5, 6, 7 belonged to different cadavers. Dissections were made by using the atraumatic surgical technique. The tendons were studied to identify the structure and number of the fibers forming them. Results: The presence of a large common tendon was found in 10 of the 11 forearms. In 4 of these, the common tendon included the tendons of all four fingers. While the common tendon included 3 fingers in four forearms, it only included tendons belonging to 2 fingers in two forearms. It was not possible in one forearm to separate the common tendon into its fibers. In another forearm, tendons belonging to each digit were separate and independent starting at the muscle-tendon junction to the attachment points. Conclusion: The majority of the cadaver forearms used in the study displayed a single large FDP tendon in the zone between the muscle-tendon joint to the carpal tunnel entry prior to being distributed into each index. This anatomical feature should be considered in choosing materials and surgical technique for Zone V FDP tendon injuries, as well as in planning the rehabilitation process. [Hand Microsurg 2012; 1(1.000: 25-29

  15. 78 FR 68907 - Agency Information Collection (Elbow and Forearm Conditions Disability Benefits Questionnaire...

    Science.gov (United States)

    2013-11-15

    ... Forearm Conditions Disability Benefits Questionnaire) Under OMB Review AGENCY: Veterans Benefits... Control No. 2900- NEW (Elbow and Forearm Conditions Disability Benefits Questionnaire)'' in any... Benefits Questionnaire)''. SUPPLEMENTARY INFORMATION: Title: Elbow and Forearm Conditions Disability...

  16. Shared sensory estimates for human motion perception and pursuit eye movements.

    Science.gov (United States)

    Mukherjee, Trishna; Battifarano, Matthew; Simoncini, Claudio; Osborne, Leslie C

    2015-06-03

    Are sensory estimates formed centrally in the brain and then shared between perceptual and motor pathways or is centrally represented sensory activity decoded independently to drive awareness and action? Questions about the brain's information flow pose a challenge because systems-level estimates of environmental signals are only accessible indirectly as behavior. Assessing whether sensory estimates are shared between perceptual and motor circuits requires comparing perceptual reports with motor behavior arising from the same sensory activity. Extrastriate visual cortex both mediates the perception of visual motion and provides the visual inputs for behaviors such as smooth pursuit eye movements. Pursuit has been a valuable testing ground for theories of sensory information processing because the neural circuits and physiological response properties of motion-responsive cortical areas are well studied, sensory estimates of visual motion signals are formed quickly, and the initiation of pursuit is closely coupled to sensory estimates of target motion. Here, we analyzed variability in visually driven smooth pursuit and perceptual reports of target direction and speed in human subjects while we manipulated the signal-to-noise level of motion estimates. Comparable levels of variability throughout viewing time and across conditions provide evidence for shared noise sources in the perception and action pathways arising from a common sensory estimate. We found that conditions that create poor, low-gain pursuit create a discrepancy between the precision of perception and that of pursuit. Differences in pursuit gain arising from differences in optic flow strength in the stimulus reconcile much of the controversy on this topic. Copyright © 2015 the authors 0270-6474/15/358515-16$15.00/0.

  17. Controlling Urban Lighting by Human Motion Patterns results from a full Scale Experiment

    DEFF Research Database (Denmark)

    Poulsen, Esben Skouboe; Andersen, Hans Jørgen; Jensen, Ole B.

    2012-01-01

    This paper presents a full-scale experiment investigating the use of human motion intensities as input for interactive illumination of a town square in the city of Aalborg in Denmark. As illuminators sixteen 3.5 meter high RGB LED lamps were used. The activity on the square was monitored by three...... thermal cameras and analysed by computer vision software from which motion intensity maps and peoples trajectories were estimated and used as input to control the interactive illumination. The paper introduces a 2-layered interactive light strategy addressing ambient and effect illumination criteria...... totally four light scenarios were designed and tested. The result shows that in general people immersed in the street lighting did not notice that the light changed according to their presence or actions, but people watching from the edge of the square noticed the interaction between the illumination...

  18. Absolute quantitation of phosphorus metabolites in the cerebral cortex of the newborn human infant and in the forearm muscles of young adults using a double-tuned surface coil

    Science.gov (United States)

    Cady, Ernest B.

    The application of a double-tuned surface coil with strong coupling for both 31P and 1H to the in vivo measurement of metabolite concentrations by NMR spectroscopy is demonstrated. It is shown that sample loading, although important for a coil tuned to a single frequency, does not necessarily have a significant effect on absolute quantitation results if the coil is strongly coupled to the sample for both nuclei. For the coil used in the present study, the spectrometer calibration coefficient is almost independent of loading and the 1H and 31P flip angles at the coil center produced by fixed length pulses could be arranged to be nearly equal over a range of loading conditions. In seven normal infants, of gestational plus postnatal age 35 to 37 weeks, the cerebral cortex nucleotide triphosphate concentration was 3.7 ± 0.6 m M/liter wet (mean ± SD). Metabolite concentrations were low in the cerebral cortex of a severely birth asphyxiated infant. The adenosine triphosphate concentration in the resting, fresh forearm muscles of six young adults was 6.3 ± 0.8 m M/liter wet.

  19. Self-Organizing Neural Integration of Pose-Motion Features for Human Action Recognition

    Directory of Open Access Journals (Sweden)

    German Ignacio Parisi

    2015-06-01

    Full Text Available The visual recognition of complex, articulated human movements is fundamental for a wide range of artificial systems oriented towards human-robot communication, action classification, and action-driven perception. These challenging tasks may generally involve the processing of a huge amount of visual information and learning-based mechanisms for generalizing a set of training actions and classifying new samples. To operate in natural environments, a crucial property is the efficient and robust recognition of actions, also under noisy conditions caused by, for instance, systematic sensor errors and temporarily occluded persons. Studies of the mammalian visual system and its outperforming ability to process biological motion information suggest separate neural pathways for the distinct processing of pose and motion features at multiple levels and the subsequent integration of these visual cues for action perception. We present a neurobiologically-motivated approach to achieve noise-tolerant action recognition in real time. Our model consists of self-organizing Growing When Required (GWR networks that obtain progressively generalized representations of sensory inputs and learn inherent spatiotemporal dependencies. During the training, the GWR networks dynamically change their topological structure to better match the input space. We first extract pose and motion features from video sequences and then cluster actions in terms of prototypical pose-motion trajectories. Multi-cue trajectories from matching action frames are subsequently combined to provide action dynamics in the joint feature space. Reported experiments show that our approach outperforms previous results on a dataset of full-body actions captured with a depth sensor, and ranks among the best 21 results for a public benchmark of domestic daily actions.

  20. Application of inertial sensors and flux-gate magnetometer to real-time human body motion capture

    OpenAIRE

    Frey, William.

    1996-01-01

    Human body tracking for synthetic environment interface has become a significant human- computer interface challenge. There are several different types of motion capture systems currently available. Inherent problems, most resulting from the use of artificially-generated source signals, plague these systems. A proposed motion capture system is being developed at the Naval Postgraduate School which utilizes a combination of inertial sensors to overcome these difficulties. However, the current ...

  1. Magnetic navigation system for the precise helical and translational motions of a microrobot in human blood vessels

    Science.gov (United States)

    Jeon, S. M.; Jang, G. H.; Choi, H. C.; Park, S. H.; Park, J. O.

    2012-04-01

    Different magnetic navigation systems (MNSs) have been investigated for the wireless manipulation of microrobots in human blood vessels. Here we propose a MNS and methodology for generation of both the precise helical and translational motions of a microrobot to improve its maneuverability in complex human blood vessel. We then present experiments demonstrating the helical and translational motions of a spiral-type microrobot to verify the proposed MNS.

  2. An Approach to Sensorless Detection of Human Input Torque and Its Application to Power Assist Motion in Electric Wheelchair

    Science.gov (United States)

    Kaida, Yukiko; Murakami, Toshiyuki

    A wheelchair is an important apparatus of mobility for people with disability. Power-assist motion in an electric wheelchair is to expand the operator's field of activities. This paper describes force sensorless detection of human input torque. Reaction torque estimation observer calculates the total disturbance torque first. Then, the human input torque is extracted from the estimated disturbance. In power-assist motion, assist torque is synthesized according to the product of assist gain and the average torque of the right and left input torque. Finally, the proposed method is verified through the experiments of power-assist motion.

  3. Acute changes in forearm venous volume and tone using radionuclide plethysmography

    International Nuclear Information System (INIS)

    Manyari, D.E.; Malkinson, T.J.; Robinson, V.; Smith, E.R.; Cooper, K.E.

    1988-01-01

    In this investigation blood pool scintigraphy was validated as a method to study acute changes in human forearm veins. Changes in regional forearm vascular volume (capacity) and the occluding pressure-volume (P-V) relationship induced by sublingual nifedipine (NIF) and nitroglycerin (GTN) were recorded in 16 patients with simultaneous data collection by the radionuclide and the mercury-in-rubber strain-gauge techniques. The standard error of estimate (Syx) between successive control measurements using the radionuclide method was 3.1% compared with 3.2% for the strain-gauge method. The venous P-V curves were highly reproducible using both techniques. Strain gauge and radionuclide measurements of acute changes in forearm venous volume correlated well (r = 0.86; Syx = 7%, n = 156). After 20 mg of NIF or 0.6 mg of GTN, mean heart rate increased from 71 +/- 10 to 77 +/- 9 and from 68 +/- 10 to 75 +/- 11 beats/min, respectively, and group systolic blood pressure decreased from 128 +/- 22 to 120 +/- 19 and from 136 +/- 18 to 126 +/- 23 mmHg, respectively (P less than 0.05). At venous occluding pressures of 0 and 30 mmHg, the forearm vascular volume did not change after NIF (2 +/- 4 and -1 +/- 4%; P greater than 0.05), whereas it increased after GTN (8 +/- 5 and 12 +/- 7%; P less than 0.001). The forearm venous P-V relationship did not change after NIF, whereas a significant rightward shift (venodilation, with an increase in unstressed volume) occurred after GTN

  4. Gravity Cues Embedded in the Kinematics of Human Motion Are Detected in Form-from-Motion Areas of the Visual System and in Motor-Related Areas.

    Science.gov (United States)

    Cignetti, Fabien; Chabeauti, Pierre-Yves; Menant, Jasmine; Anton, Jean-Luc J J; Schmitz, Christina; Vaugoyeau, Marianne; Assaiante, Christine

    2017-01-01

    The present study investigated the cortical areas engaged in the perception of graviceptive information embedded in biological motion (BM). To this end, functional magnetic resonance imaging was used to assess the cortical areas active during the observation of human movements performed under normogravity and microgravity (parabolic flight). Movements were defined by motion cues alone using point-light displays. We found that gravity modulated the activation of a restricted set of regions of the network subtending BM perception, including form-from-motion areas of the visual system (kinetic occipital region, lingual gyrus, cuneus) and motor-related areas (primary motor and somatosensory cortices). These findings suggest that compliance of observed movements with normal gravity was carried out by mapping them onto the observer's motor system and by extracting their overall form from local motion of the moving light points. We propose that judgment on graviceptive information embedded in BM can be established based on motor resonance and visual familiarity mechanisms and not necessarily by accessing the internal model of gravitational motion stored in the vestibular cortex.

  5. Human Hand Motion Analysis and Synthesis of Optimal Power Grasps for a Robotic Hand

    Directory of Open Access Journals (Sweden)

    Francesca Cordella

    2014-03-01

    Full Text Available Biologically inspired robotic systems can find important applications in biomedical robotics, since studying and replicating human behaviour can provide new insights into motor recovery, functional substitution and human-robot interaction. The analysis of human hand motion is essential for collecting information about human hand movements useful for generalizing reaching and grasping actions on a robotic system. This paper focuses on the definition and extraction of quantitative indicators for describing optimal hand grasping postures and replicating them on an anthropomorphic robotic hand. A motion analysis has been carried out on six healthy human subjects performing a transverse volar grasp. The extracted indicators point to invariant grasping behaviours between the involved subjects, thus providing some constraints for identifying the optimal grasping configuration. Hence, an optimization algorithm based on the Nelder-Mead simplex method has been developed for determining the optimal grasp configuration of a robotic hand, grounded on the aforementioned constraints. It is characterized by a reduced computational cost. The grasp stability has been tested by introducing a quality index that satisfies the form-closure property. The grasping strategy has been validated by means of simulation tests and experimental trials on an arm-hand robotic system. The obtained results have shown the effectiveness of the extracted indicators to reduce the non-linear optimization problem complexity and lead to the synthesis of a grasping posture able to replicate the human behaviour while ensuring grasp stability. The experimental results have also highlighted the limitations of the adopted robotic platform (mainly due to the mechanical structure to achieve the optimal grasp configuration.

  6. The effects of forearm fatigue on baseball fastball pitching, with implications about elbow injury.

    Science.gov (United States)

    Wang, Lin-Hwa; Lo, Kuo-Cheng; Jou, I-Ming; Kuo, Li-Chieh; Tai, Ta-Wei; Su, Fong-Chin

    2016-01-01

    This study investigated the contribution of flexor muscles to the forearm through fatigue; therefore, the differences in forearm mechanisms on the pitching motion in fastball were analysed. Fifteen baseball pitchers were included in this study. Ultrasonographical examination of participants' ulnar nerve in the cubital tunnel with the elbow extended and at 45°, 90° and 120° of flexion was carried. A three-dimensional motion analysis system with 14 reflective markers attached on participants was used for motion data collection. The electromyography system was applied over the flexor carpi ulnaris, flexor carpi radialis and extensor carpi radialis muscles of the dominant arm. Flexor carpi ulnaris muscle activity showed a significant difference during the acceleration phase, with a peak value during fastball post-fatigue (P = 0.02). Significant differences in the distance between ulnar nerve and medial condyle on throwing arm and non-throwing arm were observed as the distance increased with the elbow movement from 0° to 120° of flexion (P = 0.01). The significant increase of the flexor carpi ulnaris muscle activity might be responsible for maintaining the stability of the wrist joint. The increased diameter might compress the ulnar nerve and cause several pathological changes. Therefore, fatigue in baseball pitchers still poses a threat to the ulnar nerve because the flexor carpi ulnaris and flexor carpi radialis all originate from the medial side of the elbow, and the swelling tendons after fatigue might be a key point.

  7. Extract the Relational Information of Static Features and Motion Features for Human Activities Recognition in Videos

    Directory of Open Access Journals (Sweden)

    Li Yao

    2016-01-01

    Full Text Available Both static features and motion features have shown promising performance in human activities recognition task. However, the information included in these features is insufficient for complex human activities. In this paper, we propose extracting relational information of static features and motion features for human activities recognition. The videos are represented by a classical Bag-of-Word (BoW model which is useful in many works. To get a compact and discriminative codebook with small dimension, we employ the divisive algorithm based on KL-divergence to reconstruct the codebook. After that, to further capture strong relational information, we construct a bipartite graph to model the relationship between words of different feature set. Then we use a k-way partition to create a new codebook in which similar words are getting together. With this new codebook, videos can be represented by a new BoW vector with strong relational information. Moreover, we propose a method to compute new clusters from the divisive algorithm’s projective function. We test our work on the several datasets and obtain very promising results.

  8. Forearm Flexor Muscles in Children with Cerebral Palsy Are Weak, Thin and Stiff

    Directory of Open Access Journals (Sweden)

    Eva Pontén

    2017-04-01

    Full Text Available Children with cerebral palsy (CP often develop reduced passive range of motion with age. The determining factor underlying this process is believed to be progressive development of contracture in skeletal muscle that likely changes the biomechanics of the joints. Consequently, to identify the underlying mechanisms, we modeled the mechanical characteristics of the forearm flexors acting across the wrist joint. We investigated skeletal muscle strength (Grippit® and passive stiffness and viscosity of the forearm flexors in 15 typically developing (TD children (10 boys/5 girls, mean age 12 years, range 8–18 yrs and nine children with CP Nine children (6 boys/3 girls, mean age 11 ± 3 years (yrs, range 7–15 yrs using the NeuroFlexor® apparatus. The muscle stiffness we estimate and report is the instantaneous mechanical response of the tissue that is independent of reflex activity. Furthermore, we assessed cross-sectional area of the flexor carpi radialis (FCR muscle using ultrasound. Age and body weight did not differ significantly between the two groups. Children with CP had a significantly weaker (−65%, p < 0.01 grip and had smaller cross-sectional area (−43%, p < 0.01 of the FCR muscle. Passive stiffness of the forearm muscles in children with CP was increased 2-fold (p < 0.05 whereas viscosity did not differ significantly between CP and TD children. FCR cross-sectional area correlated to age (R2 = 0.58, p < 0.01, body weight (R2 = 0.92, p < 0.0001 and grip strength (R2 = 0.82, p < 0.0001 in TD children but only to grip strength (R2 = 0.60, p < 0.05 in children with CP. We conclude that children with CP have weaker, thinner, and stiffer forearm flexors as compared to typically developing children.

  9. Forearm lengthening by distraction osteogenesis: A report on 5 limbs in 3 cases.

    Science.gov (United States)

    Tonogai, Ichiro; Takahashi, Mitsuhiko; Tsutsui, Takahiko; Goto, Tomohiro; Hamada, Daisuke; Suzue, Naoto; Matsuura, Tetsuya; Yasui, Natsuo; Sairyo, Koichi

    2015-01-01

    Radioulnar length discrepancy causes pain and decreases function of the wrist, forearm, and elbow. Limb lengthening, which has been used in the treatment of various deformities of the forearm, is necessary to restore balance between the ulna and radius. We treated 5 limbs in 3 patients (2 boys, 1 girl; mean age 9.3 years old) with radioulnar length discrepancy by distraction osteogenesis of either the ulna or radius using external fixators. We dissected the interosseous membrane between the ulna and radius in 3 limbs in 2 cases and did not do so in 2 limbs of 1 case. These cases include 2 cases with hereditary multiple exostoses, and 1 case with multiple epiphyseal dysplasia. The results were investigated and evaluated in this study, using appropriate clinical and radiographic parameters, noting the state of the interosseous membrane, which has an important role in forearm stability. The mean fixation period was 113 days. The mean distraction distance was 22.8 mm. The mean follow-up period was 637.7 days. The mean ulnar shortening and radial articular angle respectively improved from 7.4 mm and 30.2° preoperatively to -0.1 mm and 34.8° postoperatively. Balance between the ulna and radius was restored, and the results showed significant improvements in range of motion of the joints. However, 2 unintended radial head subluxations occurred in 2 limbs without dissection of the interosseous membrane. In addition, a keloid remained in 1 limb due to pin site infection. Forearm lengthening by distraction osteogenesis was useful in our cases. It is important to recognize the function of the interosseous membrane when lengthening is performed by osteotomy of the proximal ulna by gradual distraction with an external fixator.

  10. Analyzing the Effects of Human-Aware Motion Planning on Close-Proximity Human–Robot Collaboration

    Science.gov (United States)

    Shah, Julie A.

    2015-01-01

    Objective: The objective of this work was to examine human response to motion-level robot adaptation to determine its effect on team fluency, human satisfaction, and perceived safety and comfort. Background: The evaluation of human response to adaptive robotic assistants has been limited, particularly in the realm of motion-level adaptation. The lack of true human-in-the-loop evaluation has made it impossible to determine whether such adaptation would lead to efficient and satisfying human–robot interaction. Method: We conducted an experiment in which participants worked with a robot to perform a collaborative task. Participants worked with an adaptive robot incorporating human-aware motion planning and with a baseline robot using shortest-path motions. Team fluency was evaluated through a set of quantitative metrics, and human satisfaction and perceived safety and comfort were evaluated through questionnaires. Results: When working with the adaptive robot, participants completed the task 5.57% faster, with 19.9% more concurrent motion, 2.96% less human idle time, 17.3% less robot idle time, and a 15.1% greater separation distance. Questionnaire responses indicated that participants felt safer and more comfortable when working with an adaptive robot and were more satisfied with it as a teammate than with the standard robot. Conclusion: People respond well to motion-level robot adaptation, and significant benefits can be achieved from its use in terms of both human–robot team fluency and human worker satisfaction. Application: Our conclusion supports the development of technologies that could be used to implement human-aware motion planning in collaborative robots and the use of this technique for close-proximity human–robot collaboration. PMID:25790568

  11. Design of a compact low-power human-computer interaction equipment for hand motion

    Science.gov (United States)

    Wu, Xianwei; Jin, Wenguang

    2017-01-01

    Human-Computer Interaction (HCI) raises demand of convenience, endurance, responsiveness and naturalness. This paper describes a design of a compact wearable low-power HCI equipment applied to gesture recognition. System combines multi-mode sense signals: the vision sense signal and the motion sense signal, and the equipment is equipped with the depth camera and the motion sensor. The dimension (40 mm × 30 mm) and structure is compact and portable after tight integration. System is built on a module layered framework, which contributes to real-time collection (60 fps), process and transmission via synchronous confusion with asynchronous concurrent collection and wireless Blue 4.0 transmission. To minimize equipment's energy consumption, system makes use of low-power components, managing peripheral state dynamically, switching into idle mode intelligently, pulse-width modulation (PWM) of the NIR LEDs of the depth camera and algorithm optimization by the motion sensor. To test this equipment's function and performance, a gesture recognition algorithm is applied to system. As the result presents, general energy consumption could be as low as 0.5 W.

  12. Complex Human Activity Recognition Using Smartphone and Wrist-Worn Motion Sensors.

    Science.gov (United States)

    Shoaib, Muhammad; Bosch, Stephan; Incel, Ozlem Durmaz; Scholten, Hans; Havinga, Paul J M

    2016-03-24

    The position of on-body motion sensors plays an important role in human activity recognition. Most often, mobile phone sensors at the trouser pocket or an equivalent position are used for this purpose. However, this position is not suitable for recognizing activities that involve hand gestures, such as smoking, eating, drinking coffee and giving a talk. To recognize such activities, wrist-worn motion sensors are used. However, these two positions are mainly used in isolation. To use richer context information, we evaluate three motion sensors (accelerometer, gyroscope and linear acceleration sensor) at both wrist and pocket positions. Using three classifiers, we show that the combination of these two positions outperforms the wrist position alone, mainly at smaller segmentation windows. Another problem is that less-repetitive activities, such as smoking, eating, giving a talk and drinking coffee, cannot be recognized easily at smaller segmentation windows unlike repetitive activities, like walking, jogging and biking. For this purpose, we evaluate the effect of seven window sizes (2-30 s) on thirteen activities and show how increasing window size affects these various activities in different ways. We also propose various optimizations to further improve the recognition of these activities. For reproducibility, we make our dataset publicly available.

  13. Ultrasensitive, passive and wearable sensors for monitoring human muscle motion and physiological signals.

    Science.gov (United States)

    Cai, Feng; Yi, Changrui; Liu, Shichang; Wang, Yan; Liu, Lacheng; Liu, Xiaoqing; Xu, Xuming; Wang, Li

    2016-03-15

    Flexible sensors have attracted more and more attention as a fundamental part of anthropomorphic robot research, medical diagnosis and physical health monitoring. Here, we constructed an ultrasensitive and passive flexible sensor with the advantages of low cost, lightness and wearability, electric safety and reliability. The fundamental mechanism of the sensor is based on triboelectric effect inducing electrostatic charges on the surfaces between two different materials. Just like a plate capacitor, current will be generated while the distance or size of the parallel capacitors changes caused by the small mechanical disturbance upon it and therefore the output current/voltage will be produced. Typically, the passive sensor unambiguously monitors muscle motions including hand motion from stretch-clench-stretch, mouth motion from open-bite-open, blink and respiration. Moreover, this sensor records the details of the consecutive phases in a cardiac cycle of the apex cardiogram, and identify the peaks including percussion wave, tidal wave and diastolic wave of the radial pulse wave. To record subtle human physiological signals including radial pulsilogram and apex cardiogram with excellent signal/noise ratio, stability and reproducibility, the sensor shows great potential in the applications of medical diagnosis and daily health monitoring. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Signal Quality Improvement Algorithms for MEMS Gyroscope-Based Human Motion Analysis Systems: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Jiaying Du

    2018-04-01

    Full Text Available Motion sensors such as MEMS gyroscopes and accelerometers are characterized by a small size, light weight, high sensitivity, and low cost. They are used in an increasing number of applications. However, they are easily influenced by environmental effects such as temperature change, shock, and vibration. Thus, signal processing is essential for minimizing errors and improving signal quality and system stability. The aim of this work is to investigate and present a systematic review of different signal error reduction algorithms that are used for MEMS gyroscope-based motion analysis systems for human motion analysis or have the potential to be used in this area. A systematic search was performed with the search engines/databases of the ACM Digital Library, IEEE Xplore, PubMed, and Scopus. Sixteen papers that focus on MEMS gyroscope-related signal processing and were published in journals or conference proceedings in the past 10 years were found and fully reviewed. Seventeen algorithms were categorized into four main groups: Kalman-filter-based algorithms, adaptive-based algorithms, simple filter algorithms, and compensation-based algorithms. The algorithms were analyzed and presented along with their characteristics such as advantages, disadvantages, and time limitations. A user guide to the most suitable signal processing algorithms within this area is presented.

  15. Signal Quality Improvement Algorithms for MEMS Gyroscope-Based Human Motion Analysis Systems: A Systematic Review.

    Science.gov (United States)

    Du, Jiaying; Gerdtman, Christer; Lindén, Maria

    2018-04-06

    Motion sensors such as MEMS gyroscopes and accelerometers are characterized by a small size, light weight, high sensitivity, and low cost. They are used in an increasing number of applications. However, they are easily influenced by environmental effects such as temperature change, shock, and vibration. Thus, signal processing is essential for minimizing errors and improving signal quality and system stability. The aim of this work is to investigate and present a systematic review of different signal error reduction algorithms that are used for MEMS gyroscope-based motion analysis systems for human motion analysis or have the potential to be used in this area. A systematic search was performed with the search engines/databases of the ACM Digital Library, IEEE Xplore, PubMed, and Scopus. Sixteen papers that focus on MEMS gyroscope-related signal processing and were published in journals or conference proceedings in the past 10 years were found and fully reviewed. Seventeen algorithms were categorized into four main groups: Kalman-filter-based algorithms, adaptive-based algorithms, simple filter algorithms, and compensation-based algorithms. The algorithms were analyzed and presented along with their characteristics such as advantages, disadvantages, and time limitations. A user guide to the most suitable signal processing algorithms within this area is presented.

  16. Motion of the surface of the human tympanic membrane measured with stroboscopic holography

    Science.gov (United States)

    Cheng, Jeffrey Tao; Aarnisalo, Antti A.; Harrington, Ellery; Hernandez-Montes, Maria del Socorro; Furlong, Cosme; Merchant, Saumil N.; Rosowski, John J.

    2010-01-01

    Sound-induced motion of the surface of the human tympanic membrane (TM) was studied by stroboscopic holographic interferometery, which measures the amplitude and phase of the displacement at each of about 40000 points on the surface of the TM. Measurements were made with tonal stimuli of 0.5, 1, 4 and 8 kHz. The magnitude and phase of the sinusoidal displacement of the TM at each driven frequency were derived from the fundamental Fourier component of the raw displacement data computed from stroboscopic holograms of the TM recorded at eight stimulus phases. The correlation between the Fourier estimates and measured motion data was generally above 0.9 over the entire TM surface. We used three data presentations: (i) Plots of the phasic displacements along a single chord across the surface of the TM, (ii) Phasic surface maps of the displacement of the entire TM surface, and (iii) Plots of the Fourier derived amplitude and phase-angle of the surface displacement along four diameter lines that define and bisect each of the four quadrants of the TM. These displays led to some common conclusions: At 0.5 and 1 kHz, the entire TM moved roughly in-phase with some small phase delay apparent between local areas of maximal displacement in the posterior half of the TM. At 4 and 8 kHz, the motion of the TM became more complicated with multiple local displacement maxima arranged in rings around the manubrium. The displacements at most of these maxima were roughly in-phase, while some moved out-of-phase. Superposed on this in- and out-of-phase behavior were significant cyclic variations in phase with location of less than 0.2 cycles or occasionally rapid half-cycle step-like changes in phase. The high frequency displacement amplitude and phase maps discovered in this study can not be explained by any single wave motion, but are consistent with a combination of low and higher order modal motions plus some small traveling-wave-like components. The observations of the dynamics of TM

  17. The anatomy of forearm free flap phalloplasty for transgender surgery.

    Science.gov (United States)

    Kim, S; Dennis, M; Holland, J; Terrell, M; Loukas, M; Schober, J

    2018-03-01

    Transgender surgeries are becoming more frequent and visual interpretation of anatomy is essential for both surgeons and patients. Since the forearm free flap phalloplasty was introduced in 1984, it has been known to provide reliable cosmetic and functional results for transitioning men compared with phalloplasty by different flaps. Surgical text descriptions were enhanced by the creation of new anatomic illustrations. The forearm free flap consists of the anterior forearm skin, subcutaneous tissue, fascia containing the radial artery as the perforator and its venae comitantes, cephalic and basilic veins, and lateral and medial antebrachial cutaneous nerves are demonstrated in relation to the surgically derived flap. Song's forearm free flap phalloplasty requires two surgical stages with a three-month interval between the stages: prelamination of a neourethra and construction of a neophallus. The neophallus created by forearm flap phalloplasty is reported to achieve acceptable aesthetical and psychological satisfaction, appropriate size and shape, and satisfying sexual intercourse. Despite increasing experiences in gender confirming surgery with modifications made by many authors, urethral complications including fistula and/or stricture formation are the leading causes of reoperation. The poor esthetic outcome of the forearm donor site and a decrease in rigidity of the neophallus are the main limitations. Illustrations of anatomy help inform surgical choice and understanding of risks and benefits by patients. The anatomy of the free forearm flap phalloplasty supports creation of a neophallus for transsexual anatomy revision. Clin. Anat. 31:145-151, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  18. Cross-sensory facilitation reveals neural interactions between visual and tactile motion in humans

    Directory of Open Access Journals (Sweden)

    Monica eGori

    2011-04-01

    Full Text Available Many recent studies show that the human brain integrates information across the different senses and that stimuli of one sensory modality can enhance the perception of other modalities. Here we study the processes that mediate cross-modal facilitation and summation between visual and tactile motion. We find that while summation produced a generic, non-specific improvement of thresholds, probably reflecting higher-order interaction of decision signals, facilitation reveals a strong, direction-specific interaction, which we believe reflects sensory interactions. We measured visual and tactile velocity discrimination thresholds over a wide range of base velocities and conditions. Thresholds for both visual and tactile stimuli showed the characteristic dipper function, with the minimum thresholds occurring at a given pedestal speed. When visual and tactile coherent stimuli were combined (summation condition the thresholds for these multi-sensory stimuli also showed a dipper function with the minimum thresholds occurring in a similar range to that for unisensory signals. However, the improvement of multisensory thresholds was weak and not directionally specific, well predicted by the maximum likelihood estimation model (agreeing with previous research. A different technique (facilitation did, however, reveal direction-specific enhancement. Adding a non-informative pedestal motion stimulus in one sensory modality (vision or touch selectively lowered thresholds in the other, by the same amount as pedestals in the same modality. Facilitation did not occur for neutral stimuli like sounds (that would also have reduced temporal uncertainty, nor for motion in opposite direction, even in blocked trials where the subjects knew that the motion was in the opposite direction showing that the facilitation was not under subject control. Cross-sensory facilitation is strong evidence for functionally relevant cross-sensory integration at early levels of sensory

  19. Human-directed local autonomy for motion guidance and coordination in an intelligent manufacturing system

    Science.gov (United States)

    Alford, W. A.; Kawamura, Kazuhiko; Wilkes, Don M.

    1997-12-01

    This paper discusses the problem of integrating human intelligence and skills into an intelligent manufacturing system. Our center has jointed the Holonic Manufacturing Systems (HMS) Project, an international consortium dedicated to developing holonic systems technologies. One of our contributions to this effort is in Work Package 6: flexible human integration. This paper focuses on one activity, namely, human integration into motion guidance and coordination. Much research on intelligent systems focuses on creating totally autonomous agents. At the Center for Intelligent Systems (CIS), we design robots that interact directly with a human user. We focus on using the natural intelligence of the user to simplify the design of a robotic system. The problem is finding ways for the user to interact with the robot that are efficient and comfortable for the user. Manufacturing applications impose the additional constraint that the manufacturing process should not be disturbed; that is, frequent interacting with the user could degrade real-time performance. Our research in human-robot interaction is based on a concept called human directed local autonomy (HuDL). Under this paradigm, the intelligent agent selects and executes a behavior or skill, based upon directions from a human user. The user interacts with the robot via speech, gestures, or other media. Our control software is based on the intelligent machine architecture (IMA), an object-oriented architecture which facilitates cooperation and communication among intelligent agents. In this paper we describe our research testbed, a dual-arm humanoid robot and human user, and the use of this testbed for a human directed sorting task. We also discuss some proposed experiments for evaluating the integration of the human into the robot system. At the time of this writing, the experiments have not been completed.

  20. Cold-induced vasoconstriction at forearm and hand skin sites: the effect of age

    OpenAIRE

    Kingma, B.R.M.; Frijns, A.J.H.; Saris, W.H.M.; Steenhoven, van, A.A.; Marken Lichtenbelt, van, W.D.

    2010-01-01

    During mild cold exposure, elderly are at risk of hypothermia. In humans, glabrous skin at the hands is well adapted as a heat exchanger. Evidence exists that elderly show equal vasoconstriction due to local cooling at the ventral forearm, yet no age effects on vasoconstriction at hand skin have been studied. Here, we tested the hypotheses that at hand sites (a) elderly show equal vasoconstriction due to local cooling and (b) elderly show reduced response to noradrenergic stimuli. Skin perfus...

  1. The recurrent branch of the lateral cutaneous nerve of the forearm.

    OpenAIRE

    Horiguchi, M

    1981-01-01

    Cutaneous nerves of the upper arm were observed in 31 Japanese cadavers dissected in a student course of gross anatomy dissection and in cadaver selected randomly for intensive dissection. Contrary to the descriptions in current textbooks of human anatomy, the lateral cutaneous nerve of the forearm supplies also the skin over the distal region of the anterolateral surface of the upper arm. A branch to the upper arm (the recurrent branch) arises from the proper trunk of the lateral cutaneous n...

  2. Communication between radial nerve and medial cutaneous nerve of forearm

    Directory of Open Access Journals (Sweden)

    R R Marathe

    2010-01-01

    Full Text Available Radial nerve is usually a branch of the posterior cord of the brachial plexus. It innervates triceps, anconeous, brachialis, brachioradialis, extensor carpi radialis longus muscles and gives the posterior cutaneous nerve of the arm, lower lateral cutaneous nerve of arm, posterior cutaneous nerve of forearm; without exhibiting any communication with the medial cutaneous nerve of forearm or any other nerve. We report communication between the radial nerve and medial cutaneous nerve of forearm on the left side in a 58-year-old male cadaver. The right sided structures were found to be normal. Neurosurgeons should keep such variations in mind while performing the surgeries of axilla and upper arm.

  3. Ischemic Preconditioning of One Forearm Enhances Static and Dynamic Apnea

    DEFF Research Database (Denmark)

    Kjeld, Thomas; Rasmussen, Mads Reinholdt; Jattu, Timo

    2014-01-01

    INTRODUCTION: Ischemic preconditioning enhances ergometer cycling and swimming performance. We evaluated whether ischemic preconditioning of one forearm (four times for 5 min) also affects static breath hold and underwater swimming, whereas the effect of similar preconditioning on ergometer rowing...... preconditioning reduced the forearm oxygen saturation from 65% ± 7% to 19% ± 7% (mean ± SD; P right thigh.......05). CONCLUSIONS: We conclude that while the effect of ischemic preconditioning (of one forearm) on ergometer rowing was minimal, probably because of reduced muscle oxygenation during the warm-up, ischemic preconditioning does enhance both static and dynamic apnea, supporting that muscle ischemia is an important...

  4. Modeling and experimental investigation of an impact-driven piezoelectric energy harvester from human motion

    International Nuclear Information System (INIS)

    Wei, Sheng; Hu, Hong; He, Siyuan

    2013-01-01

    An impact-driven piezoelectric energy harvester from human motion is proposed in this paper. A high-frequency PZT-5A bimorph cantilever beam with attached proof mass at the free end was selected. A frequency up-conversion strategy was realized using impulse force generated by human motion. An aluminum prototype was attached to the leg of a person on a treadmill and measurements taken of the dissipated electric energy across multiple resistances over a range of walking speeds. The outer dimensions of this prototype are 90 mm × 40 mm × 24 mm. It has been shown that the average output voltage generated by the piezoelectric bimorph increases sequentially with a faster walking speed, the power varies with the external resistances and maximum levels occur at the optimal resistance, which is consistent with the simulation result. An open circuit voltage of 2.47 V and maximum average power of 51 μW can be achieved across a 20 kΩ external load resistance and 5 km h −1 walking speed. Experimental results reveal that the impact-driven piezoelectric energy harvesting system mounted on a person’s leg has the potential for driving wearable devices. (paper)

  5. Significant Change Spotting for Periodic Human Motion Segmentation of Cleaning Tasks Using Wearable Sensors

    Directory of Open Access Journals (Sweden)

    Kai-Chun Liu

    2017-01-01

    Full Text Available The proportion of the aging population is rapidly increasing around the world, which will cause stress on society and healthcare systems. In recent years, advances in technology have created new opportunities for automatic activities of daily living (ADL monitoring to improve the quality of life and provide adequate medical service for the elderly. Such automatic ADL monitoring requires reliable ADL information on a fine-grained level, especially for the status of interaction between body gestures and the environment in the real-world. In this work, we propose a significant change spotting mechanism for periodic human motion segmentation during cleaning task performance. A novel approach is proposed based on the search for a significant change of gestures, which can manage critical technical issues in activity recognition, such as continuous data segmentation, individual variance, and category ambiguity. Three typical machine learning classification algorithms are utilized for the identification of the significant change candidate, including a Support Vector Machine (SVM, k-Nearest Neighbors (kNN, and Naive Bayesian (NB algorithm. Overall, the proposed approach achieves 96.41% in the F1-score by using the SVM classifier. The results show that the proposed approach can fulfill the requirement of fine-grained human motion segmentation for automatic ADL monitoring.

  6. Real World Testing Of A Piezoelectric Rotational Energy Harvester For Human Motion

    International Nuclear Information System (INIS)

    Pillatsch, P; Yeatman, E M; Holmes, A S

    2013-01-01

    Harvesting energy from human motion is challenging because the frequencies are generally low and random compared to industrial machinery that vibrates at much higher frequencies. One of the most promising and popular strategies to overcome this is frequency up-conversion. The transducing element is actuated at its optimal frequency of operation, higher than the source excitation frequency, through some kind of catch and release mechanism. This is beneficial for efficient power generation. Such devices have now been investigated for a few years and this paper takes a previously introduced piezoelectric rotational harvester, relying on beam plucking for the energy conversion, to the next step by testing the device during a half marathon race. The prototype and data acquisition system are described in detail and the experimental results presented. A comparison of the input excitation, based on an accelerometer readout, and the output voltage of the piezoelectric beam, recorded at the same time, confirm the successful implementation of the system. For a device functional volume of 1.85 cm 3 , a maximum power output of 7 μW was achieved when the system was worn on the upper arm. However, degradation of the piezoelectric material meant that the performance dropped rapidly from this initial level; this requires further research. Furthermore, the need for intermediate energy storage solutions is discussed, as human motion harvesters only generate power as long as the wearer is actually moving

  7. Spherical, rolling magnet generators for passive energy harvesting from human motion

    Science.gov (United States)

    Bowers, Benjamin J.; Arnold, David P.

    2009-09-01

    In this work, non-resonant, vibrational energy harvester architectures intended for human-motion energy scavenging are researched. The basic design employs a spherical, unidirectionally magnetized permanent magnet (NdFeB) ball that is allowed to move arbitrarily in a spherical cavity wrapped with copper coil windings. As the ball rotates and translates within the cage, the time-varying magnetic flux induces a voltage in the coil according to Faraday's Law. Devices ranging from 1.5 cm3 to 4 cm3 in size were tested under human activity scenarios—held in the user's hand or placed in the user's pocket while walking (4 km h-1) and running (14.5 km h-1). These harvesters have demonstrated rms voltages ranging from ~80 mV to 700 mV and time-averaged power densities up to 0.5 mW cm-3.

  8. Perforator anatomy of the radial forearm free flap versus the ulnar forearm free flap for head and neck reconstruction.

    Science.gov (United States)

    Hekner, D D; Roeling, T A P; Van Cann, E M

    2016-08-01

    The aim of this study was to investigate the vascular anatomy of the distal forearm in order to optimize the choice between the radial forearm free flap and the ulnar forearm free flap and to select the best site to harvest the flap. The radial and ulnar arteries of seven fresh cadavers were injected with epoxy resin (Araldite) and the perforating arteries were dissected. The number of clinically relevant perforators from the radial and ulnar arteries was not significantly different in the distal forearm. Most perforators were located in the proximal half of the distal one third, making this part probably the safest location for flap harvest. Close to the wrist, i.e. most distally, there were more perforators on the ulnar side than on the radial side. The ulnar artery stained 77% of the skin surface area of the forearm, showing the ulnar forearm free flap to be more suitable than the radial forearm free flap for the restoration of large defects. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  9. Testing Tactile Masking between the Forearms.

    Science.gov (United States)

    D'Amour, Sarah; Harris, Laurence R

    2016-02-10

    Masking, in which one stimulus affects the detection of another, is a classic technique that has been used in visual, auditory, and tactile research, usually using stimuli that are close together to reveal local interactions. Masking effects have also been demonstrated in which a tactile stimulus alters the perception of a touch at a distant location. Such effects can provide insight into how components of the body's representations in the brain may be linked. Occasional reports have indicated that touches on one hand or forearm can affect tactile sensitivity at corresponding contralateral locations. To explore the matching of corresponding points across the body, we can measure the spatial tuning and effect of posture on contralateral masking. Careful controls are required to rule out direct effects of the remote stimulus, for example by mechanical transmission, and also attention effects in which thresholds may be altered by the participant's attention being drawn away from the stimulus of interest. The use of this technique is beneficial as a behavioural measure for exploring which parts of the body are functionally connected and whether the two sides of the body interact in a somatotopic representation. This manuscript describes a behavioural protocol that can be used for studying contralateral tactile masking.

  10. Forearm posture and mobility in quadrupedal dinosaurs.

    Science.gov (United States)

    VanBuren, Collin S; Bonnan, Matthew

    2013-01-01

    Quadrupedality evolved four independent times in dinosaurs; however, the constraints associated with these transitions in limb anatomy and function remain poorly understood, in particular the evolution of forearm posture and rotational ability (i.e., active pronation and supination). Results of previous qualitative studies are inconsistent, likely due to an inability to quantitatively assess the likelihood of their conclusions. We attempt to quantify antebrachial posture and mobility using the radius bone because its morphology is distinct between extant sprawled taxa with a limited active pronation ability and parasagittal taxa that have an enhanced ability to actively pronate the manus. We used a sliding semi-landmark, outline-based geometric morphometric approach of the proximal radial head and a measurement of the angle of curvature of the radius in a sample of 189 mammals, 49 dinosaurs, 35 squamates, 16 birds, and 5 crocodilians. Our results of radial head morphology showed that quadrupedal ceratopsians, bipedal non-hadrosaurid ornithopods, and theropods had limited pronation/supination ability, and sauropodomorphs have unique radial head morphology that likely allowed limited rotational ability. However, the curvature of the radius showed that no dinosaurian clade had the ability to cross the radius about the ulna, suggesting parallel antebrachial elements for all quadrupedal dinosaurs. We conclude that the bipedal origins of all quadrupedal dinosaur clades could have allowed for greater disparity in forelimb posture than previously appreciated, and future studies on dinosaur posture should not limit their classifications to the overly simplistic extant dichotomy.

  11. Forearm posture and mobility in quadrupedal dinosaurs.

    Directory of Open Access Journals (Sweden)

    Collin S VanBuren

    Full Text Available Quadrupedality evolved four independent times in dinosaurs; however, the constraints associated with these transitions in limb anatomy and function remain poorly understood, in particular the evolution of forearm posture and rotational ability (i.e., active pronation and supination. Results of previous qualitative studies are inconsistent, likely due to an inability to quantitatively assess the likelihood of their conclusions. We attempt to quantify antebrachial posture and mobility using the radius bone because its morphology is distinct between extant sprawled taxa with a limited active pronation ability and parasagittal taxa that have an enhanced ability to actively pronate the manus. We used a sliding semi-landmark, outline-based geometric morphometric approach of the proximal radial head and a measurement of the angle of curvature of the radius in a sample of 189 mammals, 49 dinosaurs, 35 squamates, 16 birds, and 5 crocodilians. Our results of radial head morphology showed that quadrupedal ceratopsians, bipedal non-hadrosaurid ornithopods, and theropods had limited pronation/supination ability, and sauropodomorphs have unique radial head morphology that likely allowed limited rotational ability. However, the curvature of the radius showed that no dinosaurian clade had the ability to cross the radius about the ulna, suggesting parallel antebrachial elements for all quadrupedal dinosaurs. We conclude that the bipedal origins of all quadrupedal dinosaur clades could have allowed for greater disparity in forelimb posture than previously appreciated, and future studies on dinosaur posture should not limit their classifications to the overly simplistic extant dichotomy.

  12. Early postmenopausal diminution of forearm and spinal bone mineral density

    DEFF Research Database (Denmark)

    Bjarnason, K; Hassager, C; Ravn, Pernille

    1995-01-01

    Diminution of bone mineral density (BMD) in the spine and forearm was studied cross-sectionally in 363 women who were 6 months to 10 years postmenopausal. BMD was determined by dual-energy X-ray absorptiometry (DXA) (Hologic QDR-2000) in the lumbar spine, in both the supine lateral (LAT) and ante......Diminution of bone mineral density (BMD) in the spine and forearm was studied cross-sectionally in 363 women who were 6 months to 10 years postmenopausal. BMD was determined by dual-energy X-ray absorptiometry (DXA) (Hologic QDR-2000) in the lumbar spine, in both the supine lateral (LAT......) and anteroposterior (AP) projections, and in the distal third of the forearm. The postmenopausal diminution of BMD was best described by an exponential fit. The initial rate of postmenopausal diminution of BMD was highest in the most trabecular sites (LAT > AP > forearm), but 10-year diminution was similar at all...

  13. Evaluating Effectiveness of Modeling Motion System Feedback in the Enhanced Hess Structural Model of the Human Operator

    Science.gov (United States)

    Zaychik, Kirill; Cardullo, Frank; George, Gary; Kelly, Lon C.

    2009-01-01

    In order to use the Hess Structural Model to predict the need for certain cueing systems, George and Cardullo significantly expanded it by adding motion feedback to the model and incorporating models of the motion system dynamics, motion cueing algorithm and a vestibular system. This paper proposes a methodology to evaluate effectiveness of these innovations by performing a comparison analysis of the model performance with and without the expanded motion feedback. The proposed methodology is composed of two stages. The first stage involves fine-tuning parameters of the original Hess structural model in order to match the actual control behavior recorded during the experiments at NASA Visual Motion Simulator (VMS) facility. The parameter tuning procedure utilizes a new automated parameter identification technique, which was developed at the Man-Machine Systems Lab at SUNY Binghamton. In the second stage of the proposed methodology, an expanded motion feedback is added to the structural model. The resulting performance of the model is then compared to that of the original one. As proposed by Hess, metrics to evaluate the performance of the models include comparison against the crossover models standards imposed on the crossover frequency and phase margin of the overall man-machine system. Preliminary results indicate the advantage of having the model of the motion system and motion cueing incorporated into the model of the human operator. It is also demonstrated that the crossover frequency and the phase margin of the expanded model are well within the limits imposed by the crossover model.

  14. Thermogenic response to adrenaline during restricted blood flow in the forearm

    DEFF Research Database (Denmark)

    Simonsen, L; Stefl, B; Christensen, N J

    1999-01-01

    To elucidate the underlying mechanism behind the thermogenic effect of adrenaline in human skeletal muscle, nine healthy subjects were studied during intravenous infusion of adrenaline. Restriction of blood flow to one forearm was obtained by external compression of the brachial artery, to separate...... a direct metabolic effect of adrenaline from an effect dependent on increased blood flow. The other arm served as the control arm. In the control arm, the forearm blood flow increased 4.7-fold (from 2.0 +/- 0.3 to 9.3 +/- 1.5 mL 100 g(-1) min(-1), P adrenaline infusion. Adrenaline...... not increase (baseline period: 5.6 +/- 2.3 micromol 100 g(-1) min(-1), adrenaline period: 6.1 +/- 2.1 micromol 100 g(-1) min(-1), P = 0.54). The experimental design and the difficulties in interpretation of the result are discussed. The results give evidence for the hypothesis that the vascular system plays...

  15. Automatic Human Movement Assessment With Switching Linear Dynamic System: Motion Segmentation and Motor Performance.

    Science.gov (United States)

    de Souza Baptista, Roberto; Bo, Antonio P L; Hayashibe, Mitsuhiro

    2017-06-01

    Performance assessment of human movement is critical in diagnosis and motor-control rehabilitation. Recent developments in portable sensor technology enable clinicians to measure spatiotemporal aspects to aid in the neurological assessment. However, the extraction of quantitative information from such measurements is usually done manually through visual inspection. This paper presents a novel framework for automatic human movement assessment that executes segmentation and motor performance parameter extraction in time-series of measurements from a sequence of human movements. We use the elements of a Switching Linear Dynamic System model as building blocks to translate formal definitions and procedures from human movement analysis. Our approach provides a method for users with no expertise in signal processing to create models for movements using labeled dataset and later use it for automatic assessment. We validated our framework on preliminary tests involving six healthy adult subjects that executed common movements in functional tests and rehabilitation exercise sessions, such as sit-to-stand and lateral elevation of the arms and five elderly subjects, two of which with limited mobility, that executed the sit-to-stand movement. The proposed method worked on random motion sequences for the dual purpose of movement segmentation (accuracy of 72%-100%) and motor performance assessment (mean error of 0%-12%).

  16. Forearm diaphyseal fractures in the adolescent population: treatment and management.

    Science.gov (United States)

    Truntzer, Jeremy; Vopat, Matthew L; Kane, Patrick M; Christino, Melissa A; Katarincic, Julia; Vopat, Bryan G

    2015-02-01

    Pediatric both-bone diaphyseal forearm fractures are commonly treated in a variety of clinical settings. Most often, closed reduction followed by immobilization leads to satisfactory results. However, in the adolescent population (10-16 years of age), forearm fractures are more challenging due to less remodeling potential. The purpose of this review was to provide an overview of the anatomy, biomechanics, and treatment options relevant to adolescent patients. A systematic review of peer-reviewed publications and abstracts related to the treatment for pediatric both-bone diaphyseal forearm fractures in adolescents was carried out. Forearm fractures in the pediatric population are most common following indirect blows to the forearm. When treating these fractures using closed reduction, it is important to recognize the muscular attachments of the forearm. In roughly 70-90% of cases, closed reduction leads to adequate alignment. In all cases, return to function is the primary goal; however, exact alignment parameters remain controversial. In the adolescent population, surgical treatment has risen substantially in the last few decades. Intramedullary nailing and open reduction using plate fixation are the two most common operative techniques. Unfortunately, recent results have shown that nonunion, malunion, and overall complication rates are higher in older pediatric patients. Moreover, no consensus exists regarding one technique over another. Both-bone diaphyseal fractures in the adolescent population present unique challenges regarding optimal treatment, especially when considering surgical intervention. Further research is necessary to better understand indications for specific surgical treatment.

  17. Structure and motion of phospholipids in human plasma lipoproteins. A 31P NMR study

    International Nuclear Information System (INIS)

    Fenske, D.B.; Chana, R.S.; Parmar, Y.I.; Treleaven, W.D.; Cushley, R.J.

    1990-01-01

    The structure and motion of phospholipids in human plasma lipoproteins have been studied by using 31 P NMR. Lateral diffusion coefficients, D T , obtained from the viscosity dependence of the 31 P NMR line widths, were obtained for very low density lipoprotein (VLDL), low-density lipoprotein (LDL), high-density lipoproteins (HDL 2 , HDL 3 ), and egg PC/TO microemulsions at 25 degree C, for VLDL at 40 degree C, and for LDL at 45 degree C. In order to prove the orientation and/or order of the phospholipid head-group, estimates of the residual chemical shift anistropy, Δσ, have been obtained for all the lipoproteins and the microemulsions from the viscosity and field dependence for the 31 P NMR line widths. These results suggest differences in the orientation and/or ordering of the head-group in the HDLs. The dynamic behavior of the phosphate moiety in LDL and HDL 3 has been obtained from the temperature dependence of the 31 P spin-lattice relaxation rates. Values of the correlation time for phosphate group reorientation and the activation energy for the motion are nearly identical in LDL and HDL 3 and are similar to values obtained for phospholipid bilayers. This argues against long-lived protein-lipid interactions being the source of either the slow diffusion in LDL or the altered head-group orientation in the HDLs

  18. A Single Camera Motion Capture System for Human-Computer Interaction

    Science.gov (United States)

    Okada, Ryuzo; Stenger, Björn

    This paper presents a method for markerless human motion capture using a single camera. It uses tree-based filtering to efficiently propagate a probability distribution over poses of a 3D body model. The pose vectors and associated shapes are arranged in a tree, which is constructed by hierarchical pairwise clustering, in order to efficiently evaluate the likelihood in each frame. Anew likelihood function based on silhouette matching is proposed that improves the pose estimation of thinner body parts, i. e. the limbs. The dynamic model takes self-occlusion into account by increasing the variance of occluded body-parts, thus allowing for recovery when the body part reappears. We present two applications of our method that work in real-time on a Cell Broadband Engine™: a computer game and a virtual clothing application.

  19. Envelope statistics of self-motion signals experienced by human subjects during everyday activities: Implications for vestibular processing.

    Science.gov (United States)

    Carriot, Jérome; Jamali, Mohsen; Cullen, Kathleen E; Chacron, Maurice J

    2017-01-01

    There is accumulating evidence that the brain's neural coding strategies are constrained by natural stimulus statistics. Here we investigated the statistics of the time varying envelope (i.e. a second-order stimulus attribute that is related to variance) of rotational and translational self-motion signals experienced by human subjects during everyday activities. We found that envelopes can reach large values across all six motion dimensions (~450 deg/s for rotations and ~4 G for translations). Unlike results obtained in other sensory modalities, the spectral power of envelope signals decreased slowly for low (2 Hz) temporal frequencies and thus was not well-fit by a power law. We next compared the spectral properties of envelope signals resulting from active and passive self-motion, as well as those resulting from signals obtained when the subject is absent (i.e. external stimuli). Our data suggest that different mechanisms underlie deviation from scale invariance in rotational and translational self-motion envelopes. Specifically, active self-motion and filtering by the human body cause deviation from scale invariance primarily for translational and rotational envelope signals, respectively. Finally, we used well-established models in order to predict the responses of peripheral vestibular afferents to natural envelope stimuli. We found that irregular afferents responded more strongly to envelopes than their regular counterparts. Our findings have important consequences for understanding the coding strategies used by the vestibular system to process natural second-order self-motion signals.

  20. Feasibility of a reduction protocol in the emergency department for diaphyseal forearm fractures in children.

    Science.gov (United States)

    Pesenti, S; Litzelmann, E; Kahil, M; Mallet, C; Jehanno, P; Mercier, J-C; Ilharreborde, B; Mazda, K

    2015-09-01

    Diaphyseal forearm fractures are very common pediatric traumas. At present, distal radius metaphyseal fractures are often successfully treated with closed reduction by emergency physicians. However, the management of diaphyseal fractures remains controversial. The purpose of this study was to analyze the results of diaphyseal forearm fractures in the emergency department (ED) in children. In a prospective 2-year-study, all closed diaphyseal forearm fractures in patients under 15, with an angle of >15° and treated by closed reduction in the ED were included. Fractures with overlapping fragments were excluded. Reduction was performed by an emergency physician, with a standardized analgesic protocol (painkillers and nitrous oxide). Clinical tolerance was checked within the first 24hours, and the radiographic stability of reduction was assessed at days 8 and 15. Initial and final follow-up radiographs were analyzed. Elbow and wrist range of motion was assessed at the final follow-up. Sixty patients (41 boys and 19 girls) were included. Mean age was 5.2 years old (±3). At initial evaluation, the maximum angle was 30° (±11.3). After reduction, the maximum angle was significantly reduced (30° vs. 5°, P<0.001). Mean immobilization in a cast was 11.7 weeks (±2). There were no cast related complications in any of these children. There was no surgery for secondary displacement. Full range of motion was obtained in all patients at the final follow-up. The outcome of conservative treatment of closed diaphyseal forearm fractures, without overlapping fragments was excellent. However, reduction is usually performed in the operating room by orthopedic surgeons under general anesthesia and requires hospitalization, which is very expensive. The results of this study show that high quality care may be obtained in the ED by a trained and experienced team. These results are similar to those for distal metaphyseal fractures, which could extend the indications for reduction in the

  1. Does fluoroscopy improve outcomes in paediatric forearm fracture reduction?

    International Nuclear Information System (INIS)

    Menachem, S.; Sharfman, Z.T.; Perets, I.; Arami, A.; Eyal, G.; Drexler, M.; Chechik, O.

    2016-01-01

    Aim: To compare the radiographic results of paediatric forearm fracture reduced with and without fluoroscopic enhancement to investigate whether fractures reduced under fluoroscopic guidance would have smaller residual deformities and lower rates of re-reduction and surgery. Materials and methods: A retrospective cohort analysis was conducted comparing paediatric patients with acute forearm fracture in two trauma centres. Demographics and radiographic data from paediatric forearm fractures treated in Trauma Centre A with the aid of a C-arm fluoroscopy were compared to those treated without fluoroscopy in Trauma Centre B. Re-reduction, late displacement, post-reduction deformity, and need for surgical intervention were compared between the two groups. Results: The cohort included 229 children (175 boys and 54 girls, mean age 9.41±3.2 years, range 1–16 years) with unilateral forearm fractures (83 manipulated with fluoroscopy and 146 without). Thirty-four (15%) children underwent re-reduction procedures in the emergency department. Fifty-three (23%) children had secondary displacement in the cast, of which 18 were operated on, 20 were re-manipulated, and the remaining 15 were kept in the cast with an acceptable deformity. Twenty-nine additional children underwent operation for reasons other than secondary displacement. There were no significant differences in re-reduction and surgery rates or in post-reduction deformities between the two groups. Conclusion: The use of fluoroscopy during reduction of forearm fractures in the paediatric population apparently does not have a significant effect on patient outcomes. Reductions performed without fluoroscopy were comparably accurate in correcting deformities in both coronal and sagittal planes. - Highlights: • Compared outcomes of pediatric forearm fracture reduction with and without fluoroscopy. • The use of fluoroscopy during reduction of forearm fractures in the pediatric population apparently does not have a

  2. Integration of visual and non-visual self-motion cues during voluntary head movements in the human brain.

    Science.gov (United States)

    Schindler, Andreas; Bartels, Andreas

    2018-05-15

    Our phenomenological experience of the stable world is maintained by continuous integration of visual self-motion with extra-retinal signals. However, due to conventional constraints of fMRI acquisition in humans, neural responses to visuo-vestibular integration have only been studied using artificial stimuli, in the absence of voluntary head-motion. We here circumvented these limitations and let participants to move their heads during scanning. The slow dynamics of the BOLD signal allowed us to acquire neural signal related to head motion after the observer's head was stabilized by inflatable aircushions. Visual stimuli were presented on head-fixed display goggles and updated in real time as a function of head-motion that was tracked using an external camera. Two conditions simulated forward translation of the participant. During physical head rotation, the congruent condition simulated a stable world, whereas the incongruent condition added arbitrary lateral motion. Importantly, both conditions were precisely matched in visual properties and head-rotation. By comparing congruent with incongruent conditions we found evidence consistent with the multi-modal integration of visual cues with head motion into a coherent "stable world" percept in the parietal operculum and in an anterior part of parieto-insular cortex (aPIC). In the visual motion network, human regions MST, a dorsal part of VIP, the cingulate sulcus visual area (CSv) and a region in precuneus (Pc) showed differential responses to the same contrast. The results demonstrate for the first time neural multimodal interactions between precisely matched congruent versus incongruent visual and non-visual cues during physical head-movement in the human brain. The methodological approach opens the path to a new class of fMRI studies with unprecedented temporal and spatial control over visuo-vestibular stimulation. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Online sparse Gaussian process based human motion intent learning for an electrically actuated lower extremity exoskeleton.

    Science.gov (United States)

    Long, Yi; Du, Zhi-Jiang; Chen, Chao-Feng; Dong, Wei; Wang, Wei-Dong

    2017-07-01

    The most important step for lower extremity exoskeleton is to infer human motion intent (HMI), which contributes to achieve human exoskeleton collaboration. Since the user is in the control loop, the relationship between human robot interaction (HRI) information and HMI is nonlinear and complicated, which is difficult to be modeled by using mathematical approaches. The nonlinear approximation can be learned by using machine learning approaches. Gaussian Process (GP) regression is suitable for high-dimensional and small-sample nonlinear regression problems. GP regression is restrictive for large data sets due to its computation complexity. In this paper, an online sparse GP algorithm is constructed to learn the HMI. The original training dataset is collected when the user wears the exoskeleton system with friction compensation to perform unconstrained movement as far as possible. The dataset has two kinds of data, i.e., (1) physical HRI, which is collected by torque sensors placed at the interaction cuffs for the active joints, i.e., knee joints; (2) joint angular position, which is measured by optical position sensors. To reduce the computation complexity of GP, grey relational analysis (GRA) is utilized to specify the original dataset and provide the final training dataset. Those hyper-parameters are optimized offline by maximizing marginal likelihood and will be applied into online GP regression algorithm. The HMI, i.e., angular position of human joints, will be regarded as the reference trajectory for the mechanical legs. To verify the effectiveness of the proposed algorithm, experiments are performed on a subject at a natural speed. The experimental results show the HMI can be obtained in real time, which can be extended and employed in the similar exoskeleton systems.

  4. Collaborative real-time motion video analysis by human observer and image exploitation algorithms

    Science.gov (United States)

    Hild, Jutta; Krüger, Wolfgang; Brüstle, Stefan; Trantelle, Patrick; Unmüßig, Gabriel; Heinze, Norbert; Peinsipp-Byma, Elisabeth; Beyerer, Jürgen

    2015-05-01

    Motion video analysis is a challenging task, especially in real-time applications. In most safety and security critical applications, a human observer is an obligatory part of the overall analysis system. Over the last years, substantial progress has been made in the development of automated image exploitation algorithms. Hence, we investigate how the benefits of automated video analysis can be integrated suitably into the current video exploitation systems. In this paper, a system design is introduced which strives to combine both the qualities of the human observer's perception and the automated algorithms, thus aiming to improve the overall performance of a real-time video analysis system. The system design builds on prior work where we showed the benefits for the human observer by means of a user interface which utilizes the human visual focus of attention revealed by the eye gaze direction for interaction with the image exploitation system; eye tracker-based interaction allows much faster, more convenient, and equally precise moving target acquisition in video images than traditional computer mouse selection. The system design also builds on prior work we did on automated target detection, segmentation, and tracking algorithms. Beside the system design, a first pilot study is presented, where we investigated how the participants (all non-experts in video analysis) performed in initializing an object tracking subsystem by selecting a target for tracking. Preliminary results show that the gaze + key press technique is an effective, efficient, and easy to use interaction technique when performing selection operations on moving targets in videos in order to initialize an object tracking function.

  5. Markerless human motion tracking using hierarchical multi-swarm cooperative particle swarm optimization.

    Science.gov (United States)

    Saini, Sanjay; Zakaria, Nordin; Rambli, Dayang Rohaya Awang; Sulaiman, Suziah

    2015-01-01

    The high-dimensional search space involved in markerless full-body articulated human motion tracking from multiple-views video sequences has led to a number of solutions based on metaheuristics, the most recent form of which is Particle Swarm Optimization (PSO). However, the classical PSO suffers from premature convergence and it is trapped easily into local optima, significantly affecting the tracking accuracy. To overcome these drawbacks, we have developed a method for the problem based on Hierarchical Multi-Swarm Cooperative Particle Swarm Optimization (H-MCPSO). The tracking problem is formulated as a non-linear 34-dimensional function optimization problem where the fitness function quantifies the difference between the observed image and a projection of the model configuration. Both the silhouette and edge likelihoods are used in the fitness function. Experiments using Brown and HumanEva-II dataset demonstrated that H-MCPSO performance is better than two leading alternative approaches-Annealed Particle Filter (APF) and Hierarchical Particle Swarm Optimization (HPSO). Further, the proposed tracking method is capable of automatic initialization and self-recovery from temporary tracking failures. Comprehensive experimental results are presented to support the claims.

  6. Quantification of human motion: gait analysis-benefits and limitations to its application to clinical problems.

    Science.gov (United States)

    Simon, Sheldon R

    2004-12-01

    The technology supporting the analysis of human motion has advanced dramatically. Past decades of locomotion research have provided us with significant knowledge about the accuracy of tests performed, the understanding of the process of human locomotion, and how clinical testing can be used to evaluate medical disorders and affect their treatment. Gait analysis is now recognized as clinically useful and financially reimbursable for some medical conditions. Yet, the routine clinical use of gait analysis has seen very limited growth. The issue of its clinical value is related to many factors, including the applicability of existing technology to addressing clinical problems; the limited use of such tests to address a wide variety of medical disorders; the manner in which gait laboratories are organized, tests are performed, and reports generated; and the clinical understanding and expectations of laboratory results. Clinical use is most hampered by the length of time and costs required for performing a study and interpreting it. A "gait" report is lengthy, its data are not well understood, and it includes a clinical interpretation, all of which do not occur with other clinical tests. Current biotechnology research is seeking to address these problems by creating techniques to capture data rapidly, accurately, and efficiently, and to interpret such data by an assortment of modeling, statistical, wave interpretation, and artificial intelligence methodologies. The success of such efforts rests on both our technical abilities and communication between engineers and clinicians.

  7. Measurement of Myocardial T1ρ with a Motion Corrected, Parametric Mapping Sequence in Humans.

    Directory of Open Access Journals (Sweden)

    Sebastian Berisha

    Full Text Available To develop a robust T1ρ magnetic resonance imaging (MRI sequence for assessment of myocardial disease in humans.We developed a breath-held T1ρ mapping method using a single-shot, T1ρ-prepared balanced steady-state free-precession (bSSFP sequence. The magnetization trajectory was simulated to identify sources of T1ρ error. To limit motion artifacts, an optical flow-based image registration method was used to align T1ρ images. The reproducibility and accuracy of these methods was assessed in phantoms and 10 healthy subjects. Results are shown in 1 patient with pre-ventricular contractions (PVCs, 1 patient with chronic myocardial infarction (MI and 2 patients with hypertrophic cardiomyopathy (HCM.In phantoms, the mean bias was 1.0 ± 2.7 msec (100 msec phantom and 0.9 ± 0.9 msec (60 msec phantom at 60 bpm and 2.2 ± 3.2 msec (100 msec and 1.4 ± 0.9 msec (60 msec at 80 bpm. The coefficient of variation (COV was 2.2 (100 msec and 1.3 (60 msec at 60 bpm and 2.6 (100 msec and 1.4 (60 msec at 80 bpm. Motion correction improved the alignment of T1ρ images in subjects, as determined by the increase in Dice Score Coefficient (DSC from 0.76 to 0.88. T1ρ reproducibility was high (COV < 0.05, intra-class correlation coefficient (ICC = 0.85-0.97. Mean myocardial T1ρ value in healthy subjects was 63.5 ± 4.6 msec. There was good correspondence between late-gadolinium enhanced (LGE MRI and increased T1ρ relaxation times in patients.Single-shot, motion corrected, spin echo, spin lock MRI permits 2D T1ρ mapping in a breath-hold with good accuracy and precision.

  8. A Novel Kalman Filter for Human Motion Tracking With an Inertial-Based Dynamic Inclinometer.

    Science.gov (United States)

    Ligorio, Gabriele; Sabatini, Angelo M

    2015-08-01

    Design and development of a linear Kalman filter to create an inertial-based inclinometer targeted to dynamic conditions of motion. The estimation of the body attitude (i.e., the inclination with respect to the vertical) was treated as a source separation problem to discriminate the gravity and the body acceleration from the specific force measured by a triaxial accelerometer. The sensor fusion between triaxial gyroscope and triaxial accelerometer data was performed using a linear Kalman filter. Wrist-worn inertial measurement unit data from ten participants were acquired while performing two dynamic tasks: 60-s sequence of seven manual activities and 90 s of walking at natural speed. Stereophotogrammetric data were used as a reference. A statistical analysis was performed to assess the significance of the accuracy improvement over state-of-the-art approaches. The proposed method achieved, on an average, a root mean square attitude error of 3.6° and 1.8° in manual activities and locomotion tasks (respectively). The statistical analysis showed that, when compared to few competing methods, the proposed method improved the attitude estimation accuracy. A novel Kalman filter for inertial-based attitude estimation was presented in this study. A significant accuracy improvement was achieved over state-of-the-art approaches, due to a filter design that better matched the basic optimality assumptions of Kalman filtering. Human motion tracking is the main application field of the proposed method. Accurately discriminating the two components present in the triaxial accelerometer signal is well suited for studying both the rotational and the linear body kinematics.

  9. Predicting Missing Marker Trajectories in Human Motion Data Using Marker Intercorrelations.

    Science.gov (United States)

    Gløersen, Øyvind; Federolf, Peter

    2016-01-01

    Missing information in motion capture data caused by occlusion or detachment of markers is a common problem that is difficult to avoid entirely. The aim of this study was to develop and test an algorithm for reconstruction of corrupted marker trajectories in datasets representing human gait. The reconstruction was facilitated using information of marker inter-correlations obtained from a principal component analysis, combined with a novel weighting procedure. The method was completely data-driven, and did not require any training data. We tested the algorithm on datasets with movement patterns that can be considered both well suited (healthy subject walking on a treadmill) and less suited (transitioning from walking to running and the gait of a subject with cerebral palsy) to reconstruct. Specifically, we created 50 copies of each dataset, and corrupted them with gaps in multiple markers at random temporal and spatial positions. Reconstruction errors, quantified by the average Euclidian distance between predicted and measured marker positions, was ≤ 3 mm for the well suited dataset, even when there were gaps in up to 70% of all time frames. For the less suited datasets, median reconstruction errors were in the range 5-6 mm. However, a few reconstructions had substantially larger errors (up to 29 mm). Our results suggest that the proposed algorithm is a viable alternative both to conventional gap-filling algorithms and state-of-the-art reconstruction algorithms developed for motion capture systems. The strengths of the proposed algorithm are that it can fill gaps anywhere in the dataset, and that the gaps can be considerably longer than when using conventional interpolation techniques. Limitations are that it does not enforce musculoskeletal constraints, and that the reconstruction accuracy declines if applied to datasets with less predictable movement patterns.

  10. Subcutaneous Injection of Oxyfluorfen Herbicide to the Forearm: Case Report.

    Science.gov (United States)

    Couceiro, José; Garcia-Portal, Gonzalo; Garcia, Olga

    2017-10-01

    Background  Oxyfluorfen, a commercially available pesticide, commonly used for weed control in crop production, has been studied in terms of its toxicity, its carcinogenic properties, and its teratogenicity. We have found no reports, however, of the effects produced by an oxyfluorfen injection to the upper limb. Methods  We present the case of a 40 years old psychiatric patient, who reportedly injected her forearm accidentally while fumigating her garden. She was treated with irrigation and open forearm fasciectomy. Results  At 6 months, the patient had some tenderness at the scar; she wanted no further procedures done. Conclusion  Oxyfluorfen appeared to produce a chemical burn to the forearm tissues including the fascia, removal of the chemical product, and a limited fasciectomy, resulted in a favorable outcome.

  11. Compensation of Wave-Induced Motion and Force Phenomena for Ship-Based High Performance Robotic and Human Amplifying Systems

    Energy Technology Data Exchange (ETDEWEB)

    Love, LJL

    2003-09-24

    The decrease in manpower and increase in material handling needs on many Naval vessels provides the motivation to explore the modeling and control of Naval robotic and robotic assistive devices. This report addresses the design, modeling, control and analysis of position and force controlled robotic systems operating on the deck of a moving ship. First we provide background information that quantifies the motion of the ship, both in terms of frequency and amplitude. We then formulate the motion of the ship in terms of homogeneous transforms. This transformation provides a link between the motion of the ship and the base of a manipulator. We model the kinematics of a manipulator as a serial extension of the ship motion. We then show how to use these transforms to formulate the kinetic and potential energy of a general, multi-degree of freedom manipulator moving on a ship. As a demonstration, we consider two examples: a one degree-of-freedom system experiencing three sea states operating in a plane to verify the methodology and a 3 degree of freedom system experiencing all six degrees of ship motion to illustrate the ease of computation and complexity of the solution. The first series of simulations explore the impact wave motion has on tracking performance of a position controlled robot. We provide a preliminary comparison between conventional linear control and Repetitive Learning Control (RLC) and show how fixed time delay RLC breaks down due to the varying nature wave disturbance frequency. Next, we explore the impact wave motion disturbances have on Human Amplification Technology (HAT). We begin with a description of the traditional HAT control methodology. Simulations show that the motion of the base of the robot, due to ship motion, generates disturbances forces reflected to the operator that significantly degrade the positioning accuracy and resolution at higher sea states. As with position-controlled manipulators, augmenting the control with a Repetitive

  12. Epidemiology of forearm fractures in adults in Denmark

    DEFF Research Database (Denmark)

    Abrahamsen, Bo; Jørgensen, N R; Schwarz, P

    2015-01-01

    with less detailed information. Rates were higher than previously estimated. INTRODUCTION: Despite a significant contribution to the overall burden of osteoporotic, nonvertebral fractures, relatively little information is available about age- and gender-specific incidence rates for many countries including...... Denmark. METHODS: We used national individual patient data on inpatient and outpatient treatment to calculate rates of forearm fractures, taking readmissions into account, with subtables for distal and proximal fractures. We also calculated ratios of forearm to hip fractures that may be useful when...

  13. Electrophysiological correlates of learning-induced modulation of visual motion processing in humans

    Directory of Open Access Journals (Sweden)

    Viktor Gál

    2010-01-01

    Full Text Available Training on a visual task leads to increased perceptual and neural responses to visual features that were attended during training as well as decreased responses to neglected distractor features. However, the time course of these attention-based modulations of neural sensitivity for visual features has not been investigated before. Here we measured event related potentials (ERP in response to motion stimuli with different coherence levels before and after training on a speed discrimination task requiring object-based attentional selection of one of the two competing motion stimuli. We found that two peaks on the ERP waveform were modulated by the strength of the coherent motion signal; the response amplitude associated with motion directions that were neglected during training was smaller than the response amplitude associated with motion directions that were attended during training. The first peak of motion coherence-dependent modulation of the ERP responses was at 300 ms after stimulus onset and it was most pronounced over the occipitotemporal cortex. The second peak was around 500 ms and was focused over the parietal cortex. A control experiment suggests that the earlier motion coherence-related response modulation reflects the extraction of the coherent motion signal whereas the later peak might index accumulation and readout of motion signals by parietal decision mechanisms. These findings suggest that attention-based learning affects neural responses both at the sensory and decision processing stages.

  14. Blood flow in the forearm in patients with Rheumatoid arthritis and healthy subjects under local thermotherapy

    Directory of Open Access Journals (Sweden)

    C. Mucha

    2002-02-01

    Full Text Available Objectives: Muscle blood flow in the forearm of patients with rheuma-toid arthritis and healthy volunteers following treatment with temperature increasingarm baths, mudpacks and short- or decimeter-wave diathermy was studied in thisinvestigation. The aim of the study was to find out the difference of reactive hyperemia between the different temperature methods as well as the influence on theconsensual reaction. Subjects: Eighty patients with rheumatoid arthritis, stage 3 according toSteinbrocker, as well as 80 healthy human subjects had been assigned numerically in the four therapy- and controlgroups. Patients with diseases influencing the peripheral blood flow were excluded. Design: Blood flow was measured by venous occlusion plethysmography in both forearms with the subjects lyingsupine. The application of the local heat therapies had been excluded on the left forearm. The forearm blood flow wasmonitored before heat therapy, directly after as well as in two further 10 minutes intervals. An analysis of variancewas used to determine the influence on blood flow of the response to the heat therapies in patients with rheumatoidarthritis and healthy subjects.Results: Under homogeneous starting conditions and a statistically uniformed high blood flow in rest the reactive values of blood flow on the left-hand side of application and the right consensual side showed high significant differencesbetween all methods of therapy. Differences between the patients and the healthy subjects only showed tendencies withpartially lower reactions, concerning the patients with rheumatoid arthritis. All methods of heat therapy caused a statistically provable consensual reaction that turned out smaller after diathermic methods. Here the post therapeuticreaction of the blood flow on the side of application was also lower or rather shorter. Conclusion: Greater differences of the blood flow in rest between the patients with rheumatoid arthritis and healthysubjects

  15. [Posttraumatic torsional deformities of the forearm : Methods of measurement and decision guidelines for correction].

    Science.gov (United States)

    Blossey, R D; Krettek, C; Liodakis, E

    2018-03-01

    Forearm fractures are common in all age groups. Even if the adjacent joints are not directly involved, these fractures have an intra-articular character. One of the most common complications of these injuries is a painful limitation of the range of motion and especially of pronation and supination. This is often due to an underdiagnosed torsional deformity; however, in recent years new methods have been developed to make these torsional differences visible and quantifiable through the use of sectional imaging. The principle of measurement corresponds to that of the torsion measurement of the lower limbs. Computed tomography (CT) or magnetic resonance imaging (MRI) scans are created at defined heights. By searching for certain landmarks, torsional angles are measured in relation to a defined reference line. A new alternative is the use of 3D reformation models. The presence of a torsional deformity, especial of the radius, leads to an impairment of the pronation and supination of the forearm. In the presence of torsional deformities, radiological measurements can help to decide if an operation is needed or not. Unlike the lower limbs, there are still no uniform cut-off values as to when a correction is indicated. Decisions must be made together with the patient by taking the clinical and radiological results into account.

  16. Man-systems evaluation of moving base vehicle simulation motion cues. [human acceleration perception involving visual feedback

    Science.gov (United States)

    Kirkpatrick, M.; Brye, R. G.

    1974-01-01

    A motion cue investigation program is reported that deals with human factor aspects of high fidelity vehicle simulation. General data on non-visual motion thresholds and specific threshold values are established for use as washout parameters in vehicle simulation. A general purpose similator is used to test the contradictory cue hypothesis that acceleration sensitivity is reduced during a vehicle control task involving visual feedback. The simulator provides varying acceleration levels. The method of forced choice is based on the theory of signal detect ability.

  17. A comparative cepstral based analysis of simulated and measured S-band and X-band radar Doppler spectra of human motion

    CSIR Research Space (South Africa)

    Van Eeden, WD

    2015-10-01

    Full Text Available targets. It is also shown that, whereas the motion of most body parts of a human target can be observed in the X-band data, only the main torso sway can be observed at S-band. This implies that X-band data is well suited to cepstrum based human motion...

  18. Transparent and stretchable strain sensors based on metal nanowire microgrids for human motion monitoring

    Science.gov (United States)

    Cho, Ji Hwan; Ha, Sung-Hun; Kim, Jong-Man

    2018-04-01

    Optical transparency is increasingly considered as one of the most important characteristics required in advanced stretchable strain sensors for application in body-attachable systems. In this paper, we present an entirely solution-processed fabrication route to highly transparent and stretchable resistive strain sensors based on silver nanowire microgrids (AgNW-MGs). The AgNW-MG strain sensors are readily prepared by patterning the AgNWs on a stretchable substrate into a MG geometry via a mesh-template-assisted contact-transfer printing. The MG has a unique architecture comprising the AgNWs and can be stretched to ɛ = 35%, with high gauge factors of ˜6.9 for ɛ = 0%-30% and ˜41.1 for ɛ = 30%-35%. The sensor also shows a high optical transmittance of 77.1% ± 1.5% (at 550 nm) and stably maintains the remarkable optical performance even at high strains. In addition, the sensor responses are found to be highly reversible with negligible hysteresis and are reliable even under repetitive stretching-releasing cycles (1000 cycles at ɛ = 10%). The practicality of the AgNW-MG strain sensor is confirmed by successfully monitoring a wide range of human motions in real time after firmly laminating the device onto various body parts.

  19. Highly Stretchable and Transparent Microfluidic Strain Sensors for Monitoring Human Body Motions.

    Science.gov (United States)

    Yoon, Sun Geun; Koo, Hyung-Jun; Chang, Suk Tai

    2015-12-16

    We report a new class of simple microfluidic strain sensors with high stretchability, transparency, sensitivity, and long-term stability with no considerable hysteresis and a fast response to various deformations by combining the merits of microfluidic techniques and ionic liquids. The high optical transparency of the strain sensors was achieved by introducing refractive-index matched ionic liquids into microfluidic networks or channels embedded in an elastomeric matrix. The microfluidic strain sensors offer the outstanding sensor performance under a variety of deformations induced by stretching, bending, pressing, and twisting of the microfluidic strain sensors. The principle of our microfluidic strain sensor is explained by a theoretical model based on the elastic channel deformation. In order to demonstrate its capability of practical usage, the simple-structured microfluidic strain sensors were performed onto a finger, wrist, and arm. The highly stretchable and transparent microfluidic strain sensors were successfully applied as potential platforms for distinctively monitoring a wide range of human body motions in real time. Our novel microfluidic strain sensors show great promise for making future stretchable electronic devices.

  20. Dealing with Magnetic Disturbances in Human Motion Capture: A Survey of Techniques

    Directory of Open Access Journals (Sweden)

    Gabriele Ligorio

    2016-03-01

    Full Text Available Magnetic-Inertial Measurement Units (MIMUs based on microelectromechanical (MEMS technologies are widespread in contexts such as human motion tracking. Although they present several advantages (lightweight, size, cost, their orientation estimation accuracy might be poor. Indoor magnetic disturbances represent one of the limiting factors for their accuracy, and, therefore, a variety of work was done to characterize and compensate them. In this paper, the main compensation strategies included within Kalman-based orientation estimators are surveyed and classified according to which degrees of freedom are affected by the magnetic data and to the magnetic disturbance rejection methods implemented. By selecting a representative method from each category, four algorithms were obtained and compared in two different magnetic environments: (1 small workspace with an active magnetic source; (2 large workspace without active magnetic sources. A wrist-worn MIMU was used to acquire data from a healthy subject, whereas a stereophotogrammetric system was adopted to obtain ground-truth data. The results suggested that the model-based approaches represent the best compromise between the two testbeds. This is particularly true when the magnetic data are prevented to affect the estimation of the angles with respect to the vertical direction.

  1. Study of human body: Kinematics and kinetics of a martial arts (Silat) performers using 3D-motion capture

    Science.gov (United States)

    Soh, Ahmad Afiq Sabqi Awang; Jafri, Mohd Zubir Mat; Azraai, Nur Zaidi

    2015-04-01

    The Interest in this studies of human kinematics goes back very far in human history drove by curiosity or need for the understanding the complexity of human body motion. To find new and accurate information about the human movement as the advance computing technology became available for human movement that can perform. Martial arts (silat) were chose and multiple type of movement was studied. This project has done by using cutting-edge technology which is 3D motion capture to characterize and to measure the motion done by the performers of martial arts (silat). The camera will detect the markers (infrared reflection by the marker) around the performer body (total of 24 markers) and will show as dot in the computer software. The markers detected were analyzing using kinematic kinetic approach and time as reference. A graph of velocity, acceleration and position at time,t (seconds) of each marker was plot. Then from the information obtain, more parameters were determined such as work done, momentum, center of mass of a body using mathematical approach. This data can be used for development of the effectiveness movement in martial arts which is contributed to the people in arts. More future works can be implemented from this project such as analysis of a martial arts competition.

  2. Gesture Recognition from Data Streams of Human Motion Sensor Using Accelerated PSO Swarm Search Feature Selection Algorithm

    Directory of Open Access Journals (Sweden)

    Simon Fong

    2015-01-01

    Full Text Available Human motion sensing technology gains tremendous popularity nowadays with practical applications such as video surveillance for security, hand signing, and smart-home and gaming. These applications capture human motions in real-time from video sensors, the data patterns are nonstationary and ever changing. While the hardware technology of such motion sensing devices as well as their data collection process become relatively mature, the computational challenge lies in the real-time analysis of these live feeds. In this paper we argue that traditional data mining methods run short of accurately analyzing the human activity patterns from the sensor data stream. The shortcoming is due to the algorithmic design which is not adaptive to the dynamic changes in the dynamic gesture motions. The successor of these algorithms which is known as data stream mining is evaluated versus traditional data mining, through a case of gesture recognition over motion data by using Microsoft Kinect sensors. Three different subjects were asked to read three comic strips and to tell the stories in front of the sensor. The data stream contains coordinates of articulation points and various positions of the parts of the human body corresponding to the actions that the user performs. In particular, a novel technique of feature selection using swarm search and accelerated PSO is proposed for enabling fast preprocessing for inducing an improved classification model in real-time. Superior result is shown in the experiment that runs on this empirical data stream. The contribution of this paper is on a comparative study between using traditional and data stream mining algorithms and incorporation of the novel improved feature selection technique with a scenario where different gesture patterns are to be recognized from streaming sensor data.

  3. System analysis of sagittal plane human motion wearing an exoskeleton using marker technology

    Directory of Open Access Journals (Sweden)

    Jatsun Sergey

    2016-01-01

    Full Text Available This paper discusses various methods of obtaining time functions for joint angle that describe a exoskeleton’s motion during sit-to-stand motion. This article demonstrates that functions obtained by solving the inverse kinematics problem can be effectively used as inputs to the control system of the robot. Comparison with experimentally data obtained using marker technology is done.

  4. Biological Motion Preference in Humans at Birth: Role of Dynamic and Configural Properties

    Science.gov (United States)

    Bardi, Lara; Regolin, Lucia; Simion, Francesca

    2011-01-01

    The present study addresses the hypothesis that detection of biological motion is an intrinsic capacity of the visual system guided by a non-species-specific predisposition for the pattern of vertebrate movement and investigates the role of global vs. local information in biological motion detection. Two-day-old babies exposed to a biological…

  5. Human-Like Behavior of Robot Arms: General Considerations and the Handwriting Task-Part I: Mathematical Description of Human-Like Motion: Distributed Positioning and Virtual Fatigue

    NARCIS (Netherlands)

    Potkonjak, V.; Tzafestas, S.; Kostic, D.; Djordjevic, G.

    2001-01-01

    This two-part paper is concerned with the analysis and achievement of human-like behavior by robot arms (manipulators). The analysis involves three issues: (i) the resolution of the inverse kinematics problem of redundant robots, (ii) the separation of the end-effector's motion into two components,

  6. Traumatic bowing of forearm and lower leg in children

    International Nuclear Information System (INIS)

    Stenstroem, R.; Gripenberg, L.; Bergius, A.-R.

    1978-01-01

    Traumatic bowing of the forearm or lower leg is reported in 31 children. It is a relatively rare condition. Bowing occurs most frequently in combination with fracture of the other bone in the same extremity. In a minority of cases a bowing deformity is a single lesion. Age distribution, degree of deformity, mechanism of origin and therapy are presented and discussed. (Auth.)

  7. Perforator anatomy of the ulnar forearm fasciocutaneous flap.

    Science.gov (United States)

    Mathy, Jon A; Moaveni, Zachary; Tan, Swee T

    2012-08-01

    The ulnar forearm fasciocutaneous flap (UFFF) is a favourable alternative to the radial forearm flap when thin and pliable tissue is required. The precise anatomy of the cutaneous perforators of UFFF has not been previously reported. The position of cutaneous perforators>0.5 mm was recorded while raising 52 consecutive free UFFFs in 51 patients at our Centre. Three (6%) UFFFs in two patients demonstrated direct cutaneous supply through a superficial ulnar artery, a known anatomic variance. There was no cutaneous perforator>0.5 mm in one flap. Among the remaining 48 dissections, an average of 3 (range, 1-6) cutaneous perforators were identified. Ninety-four percent of these forearms demonstrated at least one perforator>0.5 mm within 3 cm, and all had at least one perforator within 6 cm of the midpoint of the forearm. Proximal perforators were more likely to be musculo-cutaneous through the edge of flexor carpi ulnaris or flexor digitorum superficialis, while mid- to distal perforators were septo-cutaneous. UFFF skin paddle designed to overlie an area within 3 cm of the midpoint between the medial epicondyle and the pisiform is most likely to include at least one cutaneous perforator from the ulnar artery, without a need for intra-operative skin island adjustment. This novel anatomic finding and other practical generalisations are discussed to facilitate successful elevation of UFFF. Copyright © 2012 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  8. A study of retrograde degeneration of median nerve forearm ...

    African Journals Online (AJOL)

    Introduction: Carpal tunnel syndrome (CTS) is a disorder of the hand which results from compression of the median nerve within its fibro-osseous tunnel at the wrist. The slowing in the forearm motor conduction velocity suggests the presence of retrograde degeneration. Existing studies conflict regarding a correlation ...

  9. Forearm interosseous membrane trauma: MRI diagnostic criteria and injury patterns

    Energy Technology Data Exchange (ETDEWEB)

    McGinley, Joseph C. [Stanford University Medical Center, Department of Radiology, Stanford, CA (United States); Roach, Neil [Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States); Hopgood, Brendon C. [Albert Einstein Medical Center, Department of Surgery, Philadelphia, PA (United States); Limmer, Karl [Temple University School of Medicine, Philadelphia, PA (United States); Kozin, Scott H. [Shriners Hospital for Children, Temple University and Pediatric Hand and Upper Extremity Surgeon, Philadelphia, PA (United States)

    2006-05-15

    Define criteria for interosseous membrane (IOM) injury diagnosis using MRI, and characterize patterns of IOM disruption following forearm trauma. Our hypothesis is that most IOM injuries occur along the ulnar insertion, and MRI should be obtained following forearm trauma to assess IOM competency. Sixteen cadaver forearms were subjected to longitudinal impact trauma. Prior to and following injury, MR images were examined by a board-certified musculoskeletal radiologist using pre-defined criteria for determining IOM integrity. Each specimen was dissected and the viability/pattern of injury examined. The MRI and dissection results were compared using a double-blinded methodology. Eight of the 16 specimens demonstrated IOM trauma. Seven specimens demonstrated complete IOM disruption from the ulnar insertion, and one revealed a mid-substance tear with intact origin and insertion. The dorsal oblique bundle was disrupted in four specimens. MRI analysis identified IOM injury in seven of the eight forearms. The injury location was correctly identified in six specimens when compared to dissection observations. MRI determination of IOM injury demonstrated a positive predictive value of 100%, a negative predictive value of 89%, a sensitivity of 87.5% and a specificity of 100%. (orig.)

  10. Forearm interosseous membrane trauma: MRI diagnostic criteria and injury patterns

    International Nuclear Information System (INIS)

    McGinley, Joseph C.; Roach, Neil; Hopgood, Brendon C.; Limmer, Karl; Kozin, Scott H.

    2006-01-01

    Define criteria for interosseous membrane (IOM) injury diagnosis using MRI, and characterize patterns of IOM disruption following forearm trauma. Our hypothesis is that most IOM injuries occur along the ulnar insertion, and MRI should be obtained following forearm trauma to assess IOM competency. Sixteen cadaver forearms were subjected to longitudinal impact trauma. Prior to and following injury, MR images were examined by a board-certified musculoskeletal radiologist using pre-defined criteria for determining IOM integrity. Each specimen was dissected and the viability/pattern of injury examined. The MRI and dissection results were compared using a double-blinded methodology. Eight of the 16 specimens demonstrated IOM trauma. Seven specimens demonstrated complete IOM disruption from the ulnar insertion, and one revealed a mid-substance tear with intact origin and insertion. The dorsal oblique bundle was disrupted in four specimens. MRI analysis identified IOM injury in seven of the eight forearms. The injury location was correctly identified in six specimens when compared to dissection observations. MRI determination of IOM injury demonstrated a positive predictive value of 100%, a negative predictive value of 89%, a sensitivity of 87.5% and a specificity of 100%. (orig.)

  11. Model-Based Description of Human Body Motions for Ergonomics Evaluation

    Science.gov (United States)

    Imai, Sayaka

    This paper presents modeling of Working Process and Working Simulation factory works. I focus on an example work (motion), its actual work(motion) and reference between them. An example work and its actual work can be analyzed and described as a sequence of atomic action. In order to describe workers' motion, some concepts of Atomic Unit, Model Events and Mediator are introduced. By using these concepts, we can analyze a workers' action and evaluate their works. Also, we consider it as a possible way for unifying all the data used in various applications (CAD/CAM, etc) during the design process and evaluating all subsystems in a virtual Factory.

  12. Versatility of radial forearm free flap for intraoral reconstruction

    Directory of Open Access Journals (Sweden)

    Jeremić Jelena V.

    2015-01-01

    Full Text Available Introduction. The radial forearm free flap has an important role in reconstruction of the oncologic defects in the region of head and neck. Objective. The aim was to present and evaluate clinical experience and results in the radial forearm free transfer for intraoral reconstructions after resections due to malignancies. Methods. This article illustrates the versatility and reliability of forearm single donor site in 21 patients with a variety of intraoral oncologic defects who underwent immediate (19 patients, 90.5% or delayed (2 patients, 9.5% reconstruction using free flaps from the radial forearm. Fascio-cutaneous flaps were used in patients with floor of the mouth (6 cases, buccal mucosa (5 cases, lip (1 case and a retromolar triangle (2 cases defects, or after hemiglossectomy (7 cases. In addition, the palmaris longus tendon was included with the flap in 2 patients that required oral sphincter reconstruction. Results. An overall success rate was 90.5%. Flap failures were detected in two (9.5% patients, in one patient due to late ischemic necrosis, which appeared one week after the surgery, and in another patient due to venous congestion, which could not be salvaged after immediate re-exploration. Two patients required re-exploration due to vein thrombosis. The donor site healed uneventfully in all patients, except one, who had partial loss of skin graft. Conclusion. The radial forearm free flap is, due to multiple advantages, an acceptable method for reconstructions after resection of intraoral malignancies. [Projekat Ministarstva nauke Republike Srbije, br. 41006

  13. File list: Oth.Epd.20.AllAg.Forearm_skin [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Epd.20.AllAg.Forearm_skin hg19 TFs and others Epidermis Forearm skin SRX200048,...SRX200052,SRX200050,SRX200046 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Oth.Epd.20.AllAg.Forearm_skin.bed ...

  14. File list: His.Epd.05.AllAg.Forearm_skin [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Epd.05.AllAg.Forearm_skin hg19 Histone Epidermis Forearm skin SRX200044,SRX2000...42,SRX200038,SRX200036 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/His.Epd.05.AllAg.Forearm_skin.bed ...

  15. File list: His.Epd.10.AllAg.Forearm_skin [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Epd.10.AllAg.Forearm_skin hg19 Histone Epidermis Forearm skin SRX200044,SRX2000...38,SRX200036,SRX200042 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/His.Epd.10.AllAg.Forearm_skin.bed ...

  16. File list: ALL.Epd.20.AllAg.Forearm_skin [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Epd.20.AllAg.Forearm_skin hg19 All antigens Epidermis Forearm skin SRX200048,SR...X200036,SRX200052,SRX200038,SRX200044,SRX200042,SRX200050,SRX200046 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/ALL.Epd.20.AllAg.Forearm_skin.bed ...

  17. File list: ALL.Epd.50.AllAg.Forearm_skin [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Epd.50.AllAg.Forearm_skin hg19 All antigens Epidermis Forearm skin SRX200046,SR...X200052,SRX200048,SRX200042,SRX200044,SRX200036,SRX200038,SRX200050 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/ALL.Epd.50.AllAg.Forearm_skin.bed ...

  18. File list: Oth.Epd.50.AllAg.Forearm_skin [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Epd.50.AllAg.Forearm_skin hg19 TFs and others Epidermis Forearm skin SRX200046,...SRX200052,SRX200048,SRX200050 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Oth.Epd.50.AllAg.Forearm_skin.bed ...

  19. File list: ALL.Epd.05.AllAg.Forearm_skin [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Epd.05.AllAg.Forearm_skin hg19 All antigens Epidermis Forearm skin SRX200046,SR...X200052,SRX200048,SRX200044,SRX200042,SRX200038,SRX200036,SRX200050 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/ALL.Epd.05.AllAg.Forearm_skin.bed ...

  20. File list: Oth.Epd.05.AllAg.Forearm_skin [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Epd.05.AllAg.Forearm_skin hg19 TFs and others Epidermis Forearm skin SRX200046,...SRX200052,SRX200048,SRX200050 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Oth.Epd.05.AllAg.Forearm_skin.bed ...

  1. File list: Oth.Epd.10.AllAg.Forearm_skin [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.Epd.10.AllAg.Forearm_skin hg19 TFs and others Epidermis Forearm skin SRX200046,...SRX200052,SRX200048,SRX200050 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Oth.Epd.10.AllAg.Forearm_skin.bed ...

  2. File list: His.Epd.20.AllAg.Forearm_skin [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Epd.20.AllAg.Forearm_skin hg19 Histone Epidermis Forearm skin SRX200036,SRX2000...38,SRX200044,SRX200042 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/His.Epd.20.AllAg.Forearm_skin.bed ...

  3. File list: ALL.Epd.10.AllAg.Forearm_skin [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Epd.10.AllAg.Forearm_skin hg19 All antigens Epidermis Forearm skin SRX200046,SR...X200052,SRX200048,SRX200044,SRX200038,SRX200036,SRX200042,SRX200050 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/ALL.Epd.10.AllAg.Forearm_skin.bed ...

  4. File list: His.Epd.50.AllAg.Forearm_skin [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.Epd.50.AllAg.Forearm_skin hg19 Histone Epidermis Forearm skin SRX200042,SRX2000...44,SRX200036,SRX200038 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/His.Epd.50.AllAg.Forearm_skin.bed ...

  5. Human motion characteristics in relation to feeling familiar or frightened during an announced short interaction with a proactive humanoid.

    Science.gov (United States)

    Baddoura, Ritta; Venture, Gentiane

    2014-01-01

    During an unannounced encounter between two humans and a proactive humanoid (NAO, Aldebaran Robotics), we study the dependencies between the human partners' affective experience (measured via the answers to a questionnaire) particularly regarding feeling familiar and feeling frightened, and their arm and head motion [frequency and smoothness using Inertial Measurement Units (IMU)]. NAO starts and ends its interaction with its partners by non-verbally greeting them hello (bowing) and goodbye (moving its arm). The robot is invested with a real and useful task to perform: handing each participant an envelope containing a questionnaire they need to answer. NAO's behavior varies from one partner to the other (Smooth with X vs. Resisting with Y). The results show high positive correlations between feeling familiar while interacting with the robot and: the frequency and smoothness of the human arm movement when waving back goodbye, as well as the smoothness of the head during the whole encounter. Results also show a negative dependency between feeling frightened and the frequency of the human arm movement when waving back goodbye. The principal component analysis (PCA) suggests that, in regards to the various motion measures examined in this paper, the head smoothness and the goodbye gesture frequency are the most reliable measures when it comes to considering the familiar experienced by the participants. The PCA also points out the irrelevance of the goodbye motion frequency when investigating the participants' experience of fear in its relation to their motion characteristics. The results are discussed in light of the major findings of studies on body movements and postures accompanying specific emotions.

  6. Optimization of voltage output of energy harvesters with continuous mechanical rotation extracted from human motion (Conference Presentation)

    Science.gov (United States)

    Rashid, Evan; Hamidi, Armita; Tadesse, Yonas

    2017-04-01

    With increasing popularity of portable devices for outdoor activities, portable energy harvesting devices are coming into spot light. The next generation energy harvester which is called hybrid energy harvester can employ more than one mechanism in a single device to optimize portion of the energy that can be harvested from any source of waste energy namely motion, vibration, heat and etc. In spite of few recent attempts for creating hybrid portable devices, the level of output energy still needs to be improved with the intention of employing them in commercial electronic systems or further applications. Moreover, implementing a practical hybrid energy harvester in different application for further investigation is still challenging. This proposal is projected to incorporate a novel approach to maximize and optimize the voltage output of hybrid energy harvesters to achieve a greater conversion efficiency normalized by the total mass of the hybrid device than the simple arithmetic sum of the individual harvesting mechanisms. The energy harvester model previously proposed by Larkin and Tadesse [1] is used as a baseline and a continuous unidirectional rotation is incorporated to maximize and optimize the output. The device harvest mechanical energy from oscillatory motion and convert it to electrical energy through electromagnetic and piezoelectric systems. The new designed mechanism upgrades the device in a way that can harvest energy from both rotational and linear motions by using magnets. Likewise, the piezoelectric section optimized to harvest at least 10% more energy. To the end, the device scaled down for tested with different sources of vibrations in the immediate environment, including machinery operation, bicycle, door motion while opening and closing and finally, human motions. Comparing the results from literature proved that current device has capability to be employed in commercial small electronic devices for enhancement of battery usage or as a backup

  7. Pilot study on real-time motion detection in UAS video data by human observer and image exploitation algorithm

    Science.gov (United States)

    Hild, Jutta; Krüger, Wolfgang; Brüstle, Stefan; Trantelle, Patrick; Unmüßig, Gabriel; Voit, Michael; Heinze, Norbert; Peinsipp-Byma, Elisabeth; Beyerer, Jürgen

    2017-05-01

    Real-time motion video analysis is a challenging and exhausting task for the human observer, particularly in safety and security critical domains. Hence, customized video analysis systems providing functions for the analysis of subtasks like motion detection or target tracking are welcome. While such automated algorithms relieve the human operators from performing basic subtasks, they impose additional interaction duties on them. Prior work shows that, e.g., for interaction with target tracking algorithms, a gaze-enhanced user interface is beneficial. In this contribution, we present an investigation on interaction with an independent motion detection (IDM) algorithm. Besides identifying an appropriate interaction technique for the user interface - again, we compare gaze-based and traditional mouse-based interaction - we focus on the benefit an IDM algorithm might provide for an UAS video analyst. In a pilot study, we exposed ten subjects to the task of moving target detection in UAS video data twice, once performing with automatic support, once performing without it. We compare the two conditions considering performance in terms of effectiveness (correct target selections). Additionally, we report perceived workload (measured using the NASA-TLX questionnaire) and user satisfaction (measured using the ISO 9241-411 questionnaire). The results show that a combination of gaze input and automated IDM algorithm provides valuable support for the human observer, increasing the number of correct target selections up to 62% and reducing workload at the same time.

  8. Validation of the Leap Motion Controller using markered motion capture technology.

    Science.gov (United States)

    Smeragliuolo, Anna H; Hill, N Jeremy; Disla, Luis; Putrino, David

    2016-06-14

    The Leap Motion Controller (LMC) is a low-cost, markerless motion capture device that tracks hand, wrist and forearm position. Integration of this technology into healthcare applications has begun to occur rapidly, making validation of the LMC׳s data output an important research goal. Here, we perform a detailed evaluation of the kinematic data output from the LMC, and validate this output against gold-standard, markered motion capture technology. We instructed subjects to perform three clinically-relevant wrist (flexion/extension, radial/ulnar deviation) and forearm (pronation/supination) movements. The movements were simultaneously tracked using both the LMC and a marker-based motion capture system from Motion Analysis Corporation (MAC). Adjusting for known inconsistencies in the LMC sampling frequency, we compared simultaneously acquired LMC and MAC data by performing Pearson׳s correlation (r) and root mean square error (RMSE). Wrist flexion/extension and radial/ulnar deviation showed good overall agreement (r=0.95; RMSE=11.6°, and r=0.92; RMSE=12.4°, respectively) with the MAC system. However, when tracking forearm pronation/supination, there were serious inconsistencies in reported joint angles (r=0.79; RMSE=38.4°). Hand posture significantly influenced the quality of wrist deviation (P<0.005) and forearm supination/pronation (P<0.001), but not wrist flexion/extension (P=0.29). We conclude that the LMC is capable of providing data that are clinically meaningful for wrist flexion/extension, and perhaps wrist deviation. It cannot yet return clinically meaningful data for measuring forearm pronation/supination. Future studies should continue to validate the LMC as updated versions of their software are developed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Architectural properties of the neuromuscular compartments in selected forearm skeletal muscles.

    Science.gov (United States)

    Liu, An-Tang; Liu, Ben-Li; Lu, Li-Xuan; Chen, Gang; Yu, Da-Zhi; Zhu, Lie; Guo, Rong; Dang, Rui-Shan; Jiang, Hua

    2014-07-01

    The purposes f this study were to (i) explore the possibility of splitting the selected forearm muscles into separate compartments in human subjects; (ii) quantify the architectural properties of each neuromuscular compartment; and (iii) discuss the implication of these properties in split tendon transfer procedures. Twenty upper limbs from 10 fresh human cadavers were used in this study. Ten limbs of five cadavers were used for intramuscular nerve study by modified Sihler's staining technique, which confirmed the neuromuscular compartments. The other 10 limbs were included for architectural analysis of neuromuscular compartments. The architectural features of the compartments including muscle weight, muscle length, fiber length, pennation angle, and sarcomere length were determined. Physiological cross-sectional area and fiber length/muscle length ratio were calculated. Five of the selected forearm muscles were ideal candidates for splitting, including flexor carpi ulnaris, flexor carpi radials, extensor carpi radialis brevis, extensor carpi ulnaris and pronator teres. The humeral head of pronator teres contained the longest fiber length (6.23 ± 0.31 cm), and the radial compartment of extensor carpi ulnaris contained the shortest (2.90 ± 0.28 cm). The ulnar compartment of flexor carpi ulnaris had the largest physiological cross-sectional area (5.17 ± 0.59 cm(2)), and the ulnar head of pronator teres had the smallest (0.67 ± 0.06 cm(2)). Fiber length/muscle length ratios of the neuromuscular compartments were relatively low (average 0.27 ± 0.09, range 0.18-0.39) except for the ulnar head of pronator teres, which had the highest one (0.72 ± 0.05). Using modified Sihler's technique, this research demonstrated that each compartment of these selected forearm muscles has its own neurovascular supply after being split along its central tendon. Data of the architectural properties of each neuromuscular compartment provide insight into the 'design' of their

  10. Architectural properties of the neuromuscular compartments in selected forearm skeletal muscles

    Science.gov (United States)

    Liu, An-Tang; Liu, Ben-Li; Lu, Li-Xuan; Chen, Gang; Yu, Da-Zhi; Zhu, Lie; Guo, Rong; Dang, Rui-Shan; Jiang, Hua

    2014-01-01

    The purposes f this study were to (i) explore the possibility of splitting the selected forearm muscles into separate compartments in human subjects; (ii) quantify the architectural properties of each neuromuscular compartment; and (iii) discuss the implication of these properties in split tendon transfer procedures. Twenty upper limbs from 10 fresh human cadavers were used in this study. Ten limbs of five cadavers were used for intramuscular nerve study by modified Sihler's staining technique, which confirmed the neuromuscular compartments. The other 10 limbs were included for architectural analysis of neuromuscular compartments. The architectural features of the compartments including muscle weight, muscle length, fiber length, pennation angle, and sarcomere length were determined. Physiological cross-sectional area and fiber length/muscle length ratio were calculated. Five of the selected forearm muscles were ideal candidates for splitting, including flexor carpi ulnaris, flexor carpi radials, extensor carpi radialis brevis, extensor carpi ulnaris and pronator teres. The humeral head of pronator teres contained the longest fiber length (6.23 ± 0.31 cm), and the radial compartment of extensor carpi ulnaris contained the shortest (2.90 ± 0.28 cm). The ulnar compartment of flexor carpi ulnaris had the largest physiological cross-sectional area (5.17 ± 0.59 cm2), and the ulnar head of pronator teres had the smallest (0.67 ± 0.06 cm2). Fiber length/muscle length ratios of the neuromuscular compartments were relatively low (average 0.27 ± 0.09, range 0.18–0.39) except for the ulnar head of pronator teres, which had the highest one (0.72 ± 0.05). Using modified Sihler's technique, this research demonstrated that each compartment of these selected forearm muscles has its own neurovascular supply after being split along its central tendon. Data of the architectural properties of each neuromuscular compartment provide insight into the ‘design’ of their

  11. [Basic laws of blood screw motion in human common carotid arteries].

    Science.gov (United States)

    Kulikov, V P; Kirsanov, R I

    2008-08-01

    The basic laws of blood screw motion in common carotid arteries in people were determined by means of modern ultrasound techniques for the first time. 92 healthy adults, aged 18-30, were examined. The blood flow in the middle one-third of common carotid arteries was registered by means of Color Doppler Imaging and impulse Doppler with the help of ultrasound Medison 8000EX scanner by linear transducer of 5-9 MHz. The steady registration of blood screw motion in both common carotid arteries in Color Doppler Imaging regimen was observed in 54.3 % of cases. The direction of screw stream rotation in most cases (54%) was multi-directed: in the right common carotid artery it was right, in the left common carotid artery--left (48%), and in 6% of cases it was reverse. For 46% of cases blood rotation in both common carotid arteries was one-directed (26%--right, 20%--left). The velocity parameters of rotation component of blood motion were determined, maximum velocity being 19.68 +/- 5.84 cm/sec, minimum--4.57 +/- 2.89 cm/sec, average--7.48 +/- 2.49 cm/sec, angular--10.7 +/- 2.49 sec(-1). The rated velocity of blood cells motion in screw motion with regard of screw current lines to the vessel vertical axis makes up from 158.67 +/- 32.79 to 224.39 +/- 46.37 cm/sec.

  12. Does computer use pose an occupational hazard for forearm pain; from the NUDATA study

    DEFF Research Database (Denmark)

    Kryger, Ann Isabel; Andersen, JH; Lassen, C. F.

    2003-01-01

    was associated with use of a mouse device for more than 30 hours per week, and with keyboard use more than 15 hours per week. High job demands and time pressure at baseline were risk factors for onset of forearm pain; women had a twofold increased risk of developing forearm pain. Self reported ergonomic......AIMS: To determine the occurrence of pain conditions and disorders in the forearm and to evaluate risk factors for forearm pain in a cohort of computer workers. METHODS: A total of 6943 participants with a wide range of computer use and work tasks were studied. At baseline and at one year follow up...... to severe forearm pain was 4.3%. Sixteen of 296 symptom cases met criteria for being a clinical forearm case, and 12 had signs of potential nerve entrapment. One year incidence of reported symptom cases was 1.3%; no subjects developed new signs of nerve entrapment. Increased risk of new forearm pain...

  13. Impact of Sliding Window Length in Indoor Human Motion Modes and Pose Pattern Recognition Based on Smartphone Sensors

    Directory of Open Access Journals (Sweden)

    Gaojing Wang

    2018-06-01

    Full Text Available Human activity recognition (HAR is essential for understanding people’s habits and behaviors, providing an important data source for precise marketing and research in psychology and sociology. Different approaches have been proposed and applied to HAR. Data segmentation using a sliding window is a basic step during the HAR procedure, wherein the window length directly affects recognition performance. However, the window length is generally randomly selected without systematic study. In this study, we examined the impact of window length on smartphone sensor-based human motion and pose pattern recognition. With data collected from smartphone sensors, we tested a range of window lengths on five popular machine-learning methods: decision tree, support vector machine, K-nearest neighbor, Gaussian naïve Bayesian, and adaptive boosting. From the results, we provide recommendations for choosing the appropriate window length. Results corroborate that the influence of window length on the recognition of motion modes is significant but largely limited to pose pattern recognition. For motion mode recognition, a window length between 2.5–3.5 s can provide an optimal tradeoff between recognition performance and speed. Adaptive boosting outperformed the other methods. For pose pattern recognition, 0.5 s was enough to obtain a satisfactory result. In addition, all of the tested methods performed well.

  14. Biomechanical analysis of range of motion and failure characteristics of osteoporotic spinal compression fractures in human cadaver

    Directory of Open Access Journals (Sweden)

    Robert F Heary

    2017-01-01

    Full Text Available Background: Vertebroplasty is a treatment for osteoporotic vertebral compression fractures. The optimal location of needle placement for cement injection remains a topic of debate. As such, the authors assessed the effects of location of two types of cement instillations. In addition, the motion and failure modes at the index and adjacent segments were measured. Materials and Methods: Seven human osteoporotic cadaver spines (T1-L4, cut into four consecutive vertebral segments, were utilized. Of these, following the exclusion of four specimens not suitable to utilize for analysis, a total of 24 specimens were evaluable. Segments were randomly assigned into four treatment groups: unipedicular and bipedicular injections into the superior quartile or the anatomic center of the vertebra using confidence (Confidence Spinal Cement System®, DePuy Spine, Raynham, MA, USA or polymethyl methacrylate. The specimens were subjected to nondestructive pure moments of 5 Nm, in 2.5 Nm increments, using pulleys and weights to simulate six degrees of physiological motion. A follower preload of 200 N was applied in flexion extension. Testing sequence: range of motion (ROM of intact specimen, fracture creation, cement injection, ROM after cement, and compression testing until failure. Nonconstrained motion was measured at the index and adjacent levels. Results: At the index level, no significant differences were observed in ROM in all treatment groups (P > 0.05. There was a significant increase in adjacent level motion only for the treatment group that received a unipedicular cement injection at the anatomic center. Conclusion: The location of the needle (superior or central and treatment type (unipedicular or bipedicular had no significant effect on the ROM at the index site. At the adjacent levels, a significant increase occurred with therapy through a unipedicular approach into the centrum of the vertebra at the treated segment.

  15. Epidemiology of distal forearm fractures in Oslo, Norway.

    Science.gov (United States)

    Lofthus, C M; Frihagen, F; Meyer, H E; Nordsletten, L; Melhuus, K; Falch, J A

    2008-06-01

    The population of Oslo has the highest incidence of hip fracture reported. The present study shows that the overall incidence of distal forearm fractures in Oslo is higher than in other countries and has not changed significantly when comparing the incidence of 1998/99 with 1979. The population of Oslo has the highest incidence of hip fracture reported. The present study reports the incidence of distal forearm fracture in Oslo and the fracture rates of immigrants. Patients aged > or = 20 years resident in Oslo sustaining a distal forearm fracture in a one-year period in 1998/99 were identified using electronic diagnosis registers, patient protocols, and/or X-ray registers of the clinics in Oslo. Medical records were obtained and the diagnosis verified. The age- and sex-specific incidence rates were calculated and compared with those for 1979. Data on immigrant category and country of origin of the patients were obtained. The age-adjusted fracture rates per 10,000 for the age group > or = 50 years were 109.8 and 25.4 in 1998/99 compared with 108.3 and 23.5 in 1979 for women and men, respectively (n.s.). The relative risk of fracture in Asians was 0.72 (95% CI 0.53-1.00) compared with ethnic Norwegians. The overall incidence of distal forearm fractures in Oslo is higher than in other countries and has not changed significantly when comparing the incidence of 1998/99 with 1979. Furthermore, the present data suggest that Asian immigrants in Oslo have a slightly lower fracture risk than ethnic Norwegians.

  16. Subcutaneous Injection of Oxyfluorfen Herbicide to the Forearm: Case Report

    OpenAIRE

    Couceiro, José; Garcia-Portal, Gonzalo; Garcia, Olga

    2017-01-01

    Background  Oxyfluorfen, a commercially available pesticide, commonly used for weed control in crop production, has been studied in terms of its toxicity, its carcinogenic properties, and its teratogenicity. We have found no reports, however, of the effects produced by an oxyfluorfen injection to the upper limb. Methods  We present the case of a 40 years old psychiatric patient, who reportedly injected her forearm accidentally while fumigating her garden. She was treated with irrigation and o...

  17. Non-contact wearable single forearm cardiac biopotential acquisition device

    International Nuclear Information System (INIS)

    Gonçalves, Sérgio; Martins, Raul Carneiro

    2013-01-01

    In this work the authors propose a novel approach to obtain the electrocardiogram in the forearm using non-contact sensing. This new solution should be at same time portable, ergonomic and robust, enabling its use in different set of applications. A system of four electrodes was used in an adjustable sleeve to be wrapped in the forearm. No additional electrode references were used in other body parts. In order to increase the sensitivity of the system, an harmonium like approach was used in the design of the electrodes. The prototype was then compared with a similar system with a flat conformation. The developed prototype enabled the acquisition of an ECG signal in the forearm and the inclusion of the harmonium like electrode conformation resulted in a considerable increase of the sensitivity of the system. The acquired signal did not enable the identification of all characteristic cardiac waves. However, it was possible to identify clearly a signal pattern, characteristic of the QRS complex. The properties of the acquired signal restrict their use in rigorous electrocardiographic studies, allowing, however, its application in heart rate variability monitoring and biometric identification without the disadvantages usually associated with conventional electrodes. This makes it specially useful for man-machine interfaces and automated identification

  18. Etiology and mechanisms of ulnar and median forearm nerve injuries

    Directory of Open Access Journals (Sweden)

    Puzović Vladimir

    2015-01-01

    Full Text Available Bacgraund/Aim. Most often injuries of brachial plexus and its branches disable the injured from using their arms and/or hands. The aim of this study was to investigate the etiology and mechanisms of median and ulnar forearm nerves injuries. Methods. This retrospective cohort study included 99 patients surgically treated in the Clinic of Neurosurgery, Clinical Center of Serbia, from January 1st, 2000 to December 31st, 2010. All data are obtained from the patients' histories. Results. The majority of the injured patients were male, 81 (81.8%, while only 18 (18.2% were females, both mainly with nerve injuries of the distal forearm - 75 (75.6%. Two injury mechanisms were present, transection in 85 patients and traction and contusion in 14 of the patients. The most frequent etiological factor of nerve injuries was cutting, in 61 of the patients. Nerve injuries are often associated with other injuries. In the studied patients there were 22 vascular injuries, 33 muscle and tendon injuries and 20 bone fractures. Conclusion. The majority of those patients with peripheral nerve injuries are represented in the working age population, which is a major socioeconomic problem. In our study 66 out of 99 patients were between 17 and 40 years old, in the most productive age. The fact that the majority of patients had nerve injuries of the distal forearm and that they are operated within the first 6 months after injury, promises them good functional prognosis.

  19. Augmenting forearm crutches with wireless sensors for lower limb rehabilitation

    International Nuclear Information System (INIS)

    Merrett, Geoff V; Ettabib, Mohamed A; White, Neil M; Peters, Christian; Hallett, Georgina

    2010-01-01

    Forearm crutches are frequently used in the rehabilitation of an injury to the lower limb. The recovery rate is improved if the patient correctly applies a certain fraction of their body weight (specified by a clinician) through the axis of the crutch, referred to as partial weight bearing (PWB). Incorrect weight bearing has been shown to result in an extended recovery period or even cause further damage to the limb. There is currently no minimally invasive tool for long-term monitoring of a patient's PWB in a home environment. This paper describes the research and development of an instrumented forearm crutch that has been developed to wirelessly and autonomously monitor a patient's weight bearing over the full period of their recovery, including its potential use in a home environment. A pair of standard forearm crutches are augmented with low-cost off-the-shelf wireless sensor nodes and electronic components to provide indicative measurements of the applied weight, crutch tilt and hand position on the grip. Data are wirelessly transmitted between crutches and to a remote computer (where they are processed and visualized in LabVIEW), and the patient receives biofeedback by means of an audible signal when they put too much or too little weight through the crutch. The initial results obtained highlight the capability of the instrumented crutch to support physiotherapists and patients in monitoring usage

  20. Augmenting forearm crutches with wireless sensors for lower limb rehabilitation

    Science.gov (United States)

    Merrett, Geoff V.; Ettabib, Mohamed A.; Peters, Christian; Hallett, Georgina; White, Neil M.

    2010-12-01

    Forearm crutches are frequently used in the rehabilitation of an injury to the lower limb. The recovery rate is improved if the patient correctly applies a certain fraction of their body weight (specified by a clinician) through the axis of the crutch, referred to as partial weight bearing (PWB). Incorrect weight bearing has been shown to result in an extended recovery period or even cause further damage to the limb. There is currently no minimally invasive tool for long-term monitoring of a patient's PWB in a home environment. This paper describes the research and development of an instrumented forearm crutch that has been developed to wirelessly and autonomously monitor a patient's weight bearing over the full period of their recovery, including its potential use in a home environment. A pair of standard forearm crutches are augmented with low-cost off-the-shelf wireless sensor nodes and electronic components to provide indicative measurements of the applied weight, crutch tilt and hand position on the grip. Data are wirelessly transmitted between crutches and to a remote computer (where they are processed and visualized in LabVIEW), and the patient receives biofeedback by means of an audible signal when they put too much or too little weight through the crutch. The initial results obtained highlight the capability of the instrumented crutch to support physiotherapists and patients in monitoring usage.

  1. Dual pathology proximal median nerve compression of the forearm.

    LENUS (Irish Health Repository)

    Murphy, Siun M

    2013-12-01

    We report an unusual case of synchronous pathology in the forearm- the coexistence of a large lipoma of the median nerve together with an osteochondroma of the proximal ulna, giving rise to a dual proximal median nerve compression. Proximal median nerve compression neuropathies in the forearm are uncommon compared to the prevalence of distal compression neuropathies (eg Carpal Tunnel Syndrome). Both neural fibrolipomas (Refs. 1,2) and osteochondromas of the proximal ulna (Ref. 3) in isolation are rare but well documented. Unlike that of a distal compression, a proximal compression of the median nerve will often have a definite cause. Neural fibrolipoma, also called fibrolipomatous hamartoma are rare, slow-growing, benign tumours of peripheral nerves, most often occurring in the median nerve of younger patients. To our knowledge, this is the first report of such dual pathology in the same forearm, giving rise to a severe proximal compression of the median nerve. In this case, the nerve was being pushed anteriorly by the osteochondroma, and was being compressed from within by the intraneural lipoma. This unusual case highlights the advantage of preoperative imaging as part of the workup of proximal median nerve compression.

  2. Dual pathology proximal median nerve compression of the forearm.

    Science.gov (United States)

    Murphy, Siun M; Browne, Katherine; Tuite, David J; O'Shaughnessy, Michael

    2013-12-01

    We report an unusual case of synchronous pathology in the forearm- the coexistence of a large lipoma of the median nerve together with an osteochondroma of the proximal ulna, giving rise to a dual proximal median nerve compression. Proximal median nerve compression neuropathies in the forearm are uncommon compared to the prevalence of distal compression neuropathies (eg Carpal Tunnel Syndrome). Both neural fibrolipomas (Refs. 1,2) and osteochondromas of the proximal ulna (Ref. 3) in isolation are rare but well documented. Unlike that of a distal compression, a proximal compression of the median nerve will often have a definite cause. Neural fibrolipoma, also called fibrolipomatous hamartoma are rare, slow-growing, benign tumours of peripheral nerves, most often occurring in the median nerve of younger patients. To our knowledge, this is the first report of such dual pathology in the same forearm, giving rise to a severe proximal compression of the median nerve. In this case, the nerve was being pushed anteriorly by the osteochondroma, and was being compressed from within by the intraneural lipoma. This unusual case highlights the advantage of preoperative imaging as part of the workup of proximal median nerve compression. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  3. Two-stage distraction lengthening of the forearm.

    Science.gov (United States)

    Taghinia, Amir H; Al-Sheikh, Ayman A; Panossian, Andre E; Upton, Joseph

    2013-01-01

    Single-stage lengthening of the forearm using callus distraction is well described; however, forearm lengthening using a 2-stage technique of distraction followed by bone grafting has received less attention. A 2-staged technique can be a better alternative in cases where the surgeon desires extensive lengthening. A retrospective review was undertaken of eleven 2-stage forearm lengthening procedures performed by 1 surgeon over a 15-year period. Indications were radial longitudinal deficiency (8 patients), neonatal ischemic contractures (2 patients), and septic growth arrest (1 patient). Average follow-up was 2.8 years. Distraction was performed on patients an average of 82 mm over an average duration of 24 weeks. Average time to union from the time of distractor removal and grafting was 87 days. Average healing index was 32.1 d/cm. Distraction problems were common and related to the length of time that the distractor was in place; they included pain, pin-related infections, and multiple mechanical device difficulties. Three patients had nonunion, and another had delayed union; however, additional procedures resulted in ultimate bony union in all patients. Demineralized bone matrix and autologous corticocancellous bone grafts yielded predictable healing and good functional results in short-distance distractions. For longer distractions, free vascularized fibula transfer produced the best outcomes. Intercalary cortical allografts did not heal well. Patients with neonatal Volkmann contractures had the most difficulty with distraction and healing, ultimately obtaining little to no lengthening and poor functional outcomes.

  4. Comparison of upper arm and forearm blood pressure.

    Science.gov (United States)

    Domiano, Kathy L; Hinck, Susan M; Savinske, Debra L; Hope, Kathryn L

    2008-11-01

    The upper arm is the primary site used to obtain a blood pressure measurement (BPM); however, when it is not possible to use the upper arm, the forearm is a commonly used alternate site. This study determines if there is a significant difference between upper arm and forearm BPMs among adults and examines the relationship of participant characteristics to the BPM difference. A convenience sample was recruited from a low-income, independent-living, 104-apartment complex in the Midwest. Of the 106 participants, 64% were female and 89% were White. Ages ranged from 20 to 85 years (M = 50.7). The investigators calculated the BMIs (range = 18 to 42, M = 29.3, SD = 5.4) for the 89% (n = 94) of participants who reported their weight. The forearm tended to have higher BPMs than the upper arm (M difference = 4.0 mm Hg systolic, 2.3 mm Hg diastolic). However, site differences were greatest for men, obese adults, and middle aged (36 to 65) adults.

  5. The Influences of Arm Resist Motion on a CAR Crash Test Using Hybrid III Dummy with Human-Like Arm

    Science.gov (United States)

    Kim, Yongchul; Youm, Youngil; Bae, Hanil; Choi, Hyeonki

    Safety of the occupant during the crash is very essential design element. Many researches have been investigated in reducing the fatal injury of occupant. They are focusing on the development of a dummy in order to obtain the real human-like motion. However, they have not considered the arm resist motion during the car accident. In this study, we would like to suggest the importance of the reactive force of the arm in a car crash. The influences of reactive force acting on the human upper extremity were investigated using the impedance experimental method with lumped mass model of hand system and a Hybrid III dummy with human-like arm. Impedance parameters (e.g. inertia, spring constant and damping coefficient) of the elbow joint in maximum activation level were measured by free oscillation test using single axis robot. The results showed that without seat belt, the reactive force of human arm reduced the head, chest, and femur injury, and the flexion moment of the neck is higher than that of the conventional dummy.

  6. Mapping the organization of axis of motion selective features in human area MT using high-field fMRI.

    Directory of Open Access Journals (Sweden)

    Jan Zimmermann

    Full Text Available Functional magnetic resonance imaging (fMRI at high magnetic fields has made it possible to investigate the columnar organization of the human brain in vivo with high degrees of accuracy and sensitivity. Until now, these results have been limited to the organization principles of early visual cortex (V1. While the middle temporal area (MT has been the first identified extra-striate visual area shown to exhibit a columnar organization in monkeys, evidence of MT's columnar response properties and topographic layout in humans has remained elusive. Research using various approaches suggests similar response properties as in monkeys but failed to provide direct evidence for direction or axis of motion selectivity in human area MT. By combining state of the art pulse sequence design, high spatial resolution in all three dimensions (0.8 mm isotropic, optimized coil design, ultrahigh field magnets (7 Tesla and novel high resolution cortical grid sampling analysis tools, we provide the first direct evidence for large-scale axis of motion selective feature organization in human area MT closely matching predictions from topographic columnar-level simulations.

  7. Andreas Vesalius' 500th anniversary: the initiation of hand and forearm myology.

    Science.gov (United States)

    Brinkman, R J; Hage, J J

    2015-11-01

    Andreas Vesalius (1515-1564) was the first to market an illustrated text on the freshly dissected muscular anatomy of the human hand and forearm when he published his De Fabrica Corporis Humani Libri Septem, in 1543. To commemorate his 500th birthday, we searched the second of seven books composing De Fabrica, the annotated woodcut illustrations of De Fabrica, the Tabulae Sex, and Epitome, and an eyewitness report of a public dissection by Vesalius for references to the morphology and functions of these muscles. We found Vesalius to have recognized all currently distinguished muscles except the palmaris brevis and he noted occasional absence of some muscles. Generally, he limited the origin and insertion to bones, largely disregarding attachments to membranes and fascia. Functionally, he recorded the muscles as having a single vector and operating on only one joint. We conclude that Vesalius was nearly completely correct about the anatomy of the muscles of the forearm, but much less accurate about their function. 5. © The Author(s) 2015.

  8. Exposed versus buried intramedullary implants for pediatric forearm fractures: a comparison of complications.

    Science.gov (United States)

    Kelly, Brian A; Miller, Patricia; Shore, Benjamin J; Waters, Peter M; Bae, Donald S

    2014-12-01

    The purpose of this study was to compare the rate of complications between buried and exposed intramedullary implants after fixation of pediatric forearm fractures. A retrospective comparative cohort study of 339 children treated with intramedullary fixation for displaced forearm fractures between 2004 and 2009 was performed. Implants were left exposed in 128 patients (37.8%) and buried beneath the skin in 208 patients (61.4%); 3 patients had buried and exposed hardware (0.9%). Data on demographics, injury, surgical technique, and complications were analyzed. The buried implant group was older (mean 10.3 vs. 8.5 y; P exposed implant group. The buried group had their implants removed later than the exposed group (median 3.5 vs. 1.2 mo; P exposed implants were successfully removed in the office. Complications were seen in 56 patients (16.5%). There were 16 patients (4.7%) with refracture and 12 patients (3.5%) with infection. The buried and exposed implant groups did not differ significantly with respect to refracture (3.1% vs. 7.0%; P = 0.20), infection (3.5% vs. 2.3%; P = 0.66), or overall complications (14.5% vs. 17.2%; P = 0.87). There was also no difference between groups with respect to loss of reduction, nondelayed or delayed union, loss of motion, hypertrophic granuloma, or tendon rupture. Buried implants were also associated with penetration through the skin (3.9%). Injury to the dominant arm and need for open reduction were significant predictors of complication (OR = 1.01; 95% CI, 1.001-1.012; P = 0.02 and OR = 0.51; 95% CI, 0.264-0.974; P = 0.04, respectively). There were no significant differences seen in number of infections, refractures, or overall complications based on whether implants were left exposed or buried beneath the skin after surgery. Level III, therapeutic.

  9. A single theoretical framework for circular features processing in humans: orientation and direction of motion compared

    Directory of Open Access Journals (Sweden)

    Tzvetomir eTzvetanov

    2012-05-01

    Full Text Available Common computational principles underly processing of various visual features in the cortex. They are considered to create similar patterns of contextual modulations in behavioral studies for different features as orientation and direction of motion. Here, I studied the possibility that a single theoretical framework, implemented in different visual areas, of circular feature coding and processing could explain these similarities in observations. Stimuli were created that allowed direct comparison of the contextual effects on orientation and motion direction with two different psychophysical probes: changes in weak and strong signal perception. One unique simplified theoretical model of circular feature coding including only inhibitory interactions, and decoding through standard vector average, successfully predicted the similarities in the two domains, while different feature population characteristics explained well the differences in modulation on both experimental probes. These results demonstrate how a single computational principle underlies processing of various features across the cortices.

  10. RGO-coated elastic fibres as wearable strain sensors for full-scale detection of human motions

    Science.gov (United States)

    Mi, Qing; Wang, Qi; Zang, Siyao; Mao, Guoming; Zhang, Jinnan; Ren, Xiaomin

    2018-01-01

    In this study, we chose highly-elastic fabric fibres as the functional carrier and then simply coated the fibres with reduced graphene oxide (rGO) using plasma treatment, dip coating and hydrothermal reduction steps, finally making a wearable strain sensor. As a result, the full-scale detection of human motions, ranging from bending joints to the pulse beat, has been achieved by these sensors. Moreover, high sensitivity, good stability and excellent repeatability were realized. The good sensing performances and economical fabrication process of this wearable strain sensor have strengthened our confidence in practical applications in smart clothing, smart fabrics, healthcare, and entertainment fields.

  11. Human body motion tracking based on quantum-inspired immune cloning algorithm

    Science.gov (United States)

    Han, Hong; Yue, Lichuan; Jiao, Licheng; Wu, Xing

    2009-10-01

    In a static monocular camera system, to gain a perfect 3D human body posture is a great challenge for Computer Vision technology now. This paper presented human postures recognition from video sequences using the Quantum-Inspired Immune Cloning Algorithm (QICA). The algorithm included three parts. Firstly, prior knowledge of human beings was used, the key joint points of human could be detected automatically from the human contours and skeletons which could be thinning from the contours; And due to the complexity of human movement, a forecasting mechanism of occlusion joint points was addressed to get optimum 2D key joint points of human body; And then pose estimation recovered by optimizing between the 2D projection of 3D human key joint points and 2D detection key joint points using QICA, which recovered the movement of human body perfectly, because this algorithm could acquire not only the global optimal solution, but the local optimal solution.

  12. Velocity storage contribution to vestibular self-motion perception in healthy human subjects.

    Science.gov (United States)

    Bertolini, G; Ramat, S; Laurens, J; Bockisch, C J; Marti, S; Straumann, D; Palla, A

    2011-01-01

    Self-motion perception after a sudden stop from a sustained rotation in darkness lasts approximately as long as reflexive eye movements. We hypothesized that, after an angular velocity step, self-motion perception and reflexive eye movements are driven by the same vestibular pathways. In 16 healthy subjects (25-71 years of age), perceived rotational velocity (PRV) and the vestibulo-ocular reflex (rVOR) after sudden decelerations (90°/s(2)) from constant-velocity (90°/s) earth-vertical axis rotations were simultaneously measured (PRV reported by hand-lever turning; rVOR recorded by search coils). Subjects were upright (yaw) or 90° left-ear-down (pitch). After both yaw and pitch decelerations, PRV rose rapidly and showed a plateau before decaying. In contrast, slow-phase eye velocity (SPV) decayed immediately after the initial increase. SPV and PRV were fitted with the sum of two exponentials: one time constant accounting for the semicircular canal (SCC) dynamics and one time constant accounting for a central process, known as velocity storage mechanism (VSM). Parameters were constrained by requiring equal SCC time constant and VSM time constant for SPV and PRV. The gains weighting the two exponential functions were free to change. SPV were accurately fitted (variance-accounted-for: 0.85 ± 0.10) and PRV (variance-accounted-for: 0.86 ± 0.07), showing that SPV and PRV curve differences can be explained by a greater relative weight of VSM in PRV compared with SPV (twofold for yaw, threefold for pitch). These results support our hypothesis that self-motion perception after angular velocity steps is be driven by the same central vestibular processes as reflexive eye movements and that no additional mechanisms are required to explain the perceptual dynamics.

  13. Time and motion, experiment M151. [human performance and space flight stress

    Science.gov (United States)

    Kubis, J. F.; Elrod, J. T.; Rusnak, R.; Mcbride, G. H.; Barnes, J. E.; Saxon, S. C.

    1973-01-01

    Astronaut work performance during the preparation and execution of experiments in simulated Skylab tests was analyzed according to time and motion in order to evaluate the efficiency and consistency of performance (adaptation function) for several different types of activity over the course of the mission; to evaluate the procedures to be used by the same experiment in Skylab; to generate characteristic adaptation functions for later comparison with Skylab data; and to examine astronaut performance for any behavioral stress due to the environment. The overall results indicate that the anticipated adaptation function was obtained both for individual and for averaged data.

  14. A general-purpose framework to simulate musculoskeletal system of human body: using a motion tracking approach.

    Science.gov (United States)

    Ehsani, Hossein; Rostami, Mostafa; Gudarzi, Mohammad

    2016-02-01

    Computation of muscle force patterns that produce specified movements of muscle-actuated dynamic models is an important and challenging problem. This problem is an undetermined one, and then a proper optimization is required to calculate muscle forces. The purpose of this paper is to develop a general model for calculating all muscle activation and force patterns in an arbitrary human body movement. For this aim, the equations of a multibody system forward dynamics, which is considered for skeletal system of the human body model, is derived using Lagrange-Euler formulation. Next, muscle contraction dynamics is added to this model and forward dynamics of an arbitrary musculoskeletal system is obtained. For optimization purpose, the obtained model is used in computed muscle control algorithm, and a closed-loop system for tracking desired motions is derived. Finally, a popular sport exercise, biceps curl, is simulated by using this algorithm and the validity of the obtained results is evaluated via EMG signals.

  15. Osteoradionecrosis of the olecranon: treatment by radial forearm flap

    International Nuclear Information System (INIS)

    Thornton, J.W.; Stevenson, T.R.; VanderKolk, C.A.

    1987-01-01

    Osteoradionecrosis of the olecranon is an unusual pathologic entity, treated best by debridement and wound closure using vascularized tissue. Local skin is often unavailable for flap design and transposition. The radial forearm flap can be isolated on a proximal vascular pedicle and transposed to cover the wound. In the case presented, healing was brisk and complete, allowing early elbow mobilization. Although the donor site is not easily concealed, no functional impairment results from flap elevation and all full-thickness wounds are confined to the involved extremity

  16. Augmenting forearm crutches with wireless sensors for lower limb rehabilitation

    OpenAIRE

    Merrett, Geoff V.; Ettabib, Mohamed A.; Peters, Christian; Hallett, Georgina; White, Neil M.

    2010-01-01

    Forearm crutches are frequently used in the rehabilitation of an injury to the lower limb. The recovery rate is improved if the patient correctly applies a certain fraction of their body weight (specified by a clinician) through the axis of the crutch, referred to as partial weight bearing (PWB). Incorrect weight bearing has been shown to result in an extended recovery period or even cause further damage to the limb. There is currently no minimally invasive tool for long-term monitoring of a ...

  17. Perimenopausal risk of falling and incidence of distal forearm fracture.

    OpenAIRE

    Winner, S. J.; Morgan, C. A.; Evans, J. G.

    1989-01-01

    A postal survey of 2000 women and 2000 men sampled from the electoral roll in Oxford was undertaken to ascertain whether changes with age in the risk of falling might explain the stepwise increases in age specific incidence rates of distal forearm fracture which occur in women at around the age of 50. Corrected response rates were 83% for women and 72% for men. In women, but not in men, there was a rise in the risk of falling from 45 years, peaking in the 55-59 year age group, and sinking to ...

  18. Squared ligament of the elbow: anatomy and contribution to forearm stability.

    Science.gov (United States)

    Otayek, Salma; Tayeb, Abd-el-Kader Ait; Assabah, Bouchra; Viard, Brice; Dayan, Romain; Lazure, Thierry; Soubeyrand, Marc

    2016-03-01

    The present study describes the macroscopic and microscopic features of the squared ligament of the elbow (SLE). In addition, the SLE biomechanical behavior and contribution to the forearm stability were also examined. Ten forearms from freshly frozen cadavers were used for this work. Each forearm was mounted in an experimental frame for quantification of longitudinal and transverse stability. Macroscopic features and biomechanical behavior were analyzed on dynamic videos obtained during forearm rotation. Then, the SLE was harvested from the 10 forearms for microscopic analysis on histological slices stained with hematoxylin-eosin-saffron. Two main SLE configurations were identified. One in which the SLE had three distinct bundles (anterior, middle, posterior) and another in which it was homogeneous. The anterior part of the SLE had a mean length of 11.2 mm (±2.4 mm) and a mean width of 1.2 mm (±0.2 mm) while the posterior part had a mean length of 9.9 mm (±2.2 mm) and a mean width of 1 mm (±0.2 mm). Microscopic examination showed that the SLE is composed of a thin layer of arranged collagen fibers. During forearm rotation, the SLE progressively tightens upon pronation and supination by wrapping around the radial neck. Tightening of the SLE during forearm rotation provides transverse and longitudinal stability to the forearm, mainly in maximal pronation and supination. The SLE is a true ligament and provides forearm stability when it is stretched in pronation and supination.

  19. Recognizing human actions by learning and matching shape-motion prototype trees.

    Science.gov (United States)

    Jiang, Zhuolin; Lin, Zhe; Davis, Larry S

    2012-03-01

    A shape-motion prototype-based approach is introduced for action recognition. The approach represents an action as a sequence of prototypes for efficient and flexible action matching in long video sequences. During training, an action prototype tree is learned in a joint shape and motion space via hierarchical K-means clustering and each training sequence is represented as a labeled prototype sequence; then a look-up table of prototype-to-prototype distances is generated. During testing, based on a joint probability model of the actor location and action prototype, the actor is tracked while a frame-to-prototype correspondence is established by maximizing the joint probability, which is efficiently performed by searching the learned prototype tree; then actions are recognized using dynamic prototype sequence matching. Distance measures used for sequence matching are rapidly obtained by look-up table indexing, which is an order of magnitude faster than brute-force computation of frame-to-frame distances. Our approach enables robust action matching in challenging situations (such as moving cameras, dynamic backgrounds) and allows automatic alignment of action sequences. Experimental results demonstrate that our approach achieves recognition rates of 92.86 percent on a large gesture data set (with dynamic backgrounds), 100 percent on the Weizmann action data set, 95.77 percent on the KTH action data set, 88 percent on the UCF sports data set, and 87.27 percent on the CMU action data set.

  20. FY1995 development of rehabilitation system for promoting social integration of people with disabilities. Development of a robotic orthosis assisting motion capabilities; 1995 nendo shogaino aru hito no shakai shinshutsu wo sokushinsuru rehabilitation system no kaihatsu. Rehabilitation kino wo yusuru doryoku sogu no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    People with slight disabilities on motion. capability can be active in daily life using properly designed motion-assisting devices. Using these device in various cases would help the disabled participate in production activities, and would promote social integration of the disabled as rehabilitation in a broad sense. This research aims at developing such a device capable to help human motion by forearm based on technology and science in robotics. Two different methods are discussed in this research in order to develop robotic orthosis with good performance for assisting human motion by forearm. The first method is constructing a robotic orthosis with electronic motors and force sensors to produce a desired mechanical impedance. This orthosis was carefully designed such that mechanical safety for human is realized. The validity of the mechanism is illustrated by several experiments. The second method is constructing a low cost robotic orthosis with pneumatic actuators. A new type of pneumatic actuator is developed to realize this orthosis. Experimental results show that physical therapy can be performed effectively using this orthosis operated by direct teaching. (NEDO)

  1. Methods for Motion Correction Evaluation Using 18F-FDG Human Brain Scans on a High-Resolution PET Scanner

    DEFF Research Database (Denmark)

    Keller, Sune H.; Sibomana, Merence; Olesen, Oline Vinter

    2012-01-01

    Many authors have reported the importance of motion correction (MC) for PET. Patient motion during scanning disturbs kinetic analysis and degrades resolution. In addition, using misaligned transmission for attenuation and scatter correction may produce regional quantification bias in the reconstr......Many authors have reported the importance of motion correction (MC) for PET. Patient motion during scanning disturbs kinetic analysis and degrades resolution. In addition, using misaligned transmission for attenuation and scatter correction may produce regional quantification bias...... in the reconstructed emission images. The purpose of this work was the development of quality control (QC) methods for MC procedures based on external motion tracking (EMT) for human scanning using an optical motion tracking system. Methods: Two scans with minor motion and 5 with major motion (as reported...... (automated image registration) software. The following 3 QC methods were used to evaluate the EMT and AIR MC: a method using the ratio between 2 regions of interest with gray matter voxels (GM) and white matter voxels (WM), called GM/WM; mutual information; and cross correlation. Results: The results...

  2. A rotary multimodal hybrid energy harvesting device powered by human motion

    Science.gov (United States)

    Larkin, Miles R.

    This thesis presents a novel hybrid multimodal energy harvesting device consisting of an unbalanced rotary disk that supports two transduction methods, piezoelectric and electromagnetic. The device generates electrical energy from oscillatory motion either orthogonal or parallel to the rotary axis to power electronic devices. Analytical models of the device were developed, from which numerical simulations were performed for several different generator sizes. Two prototypes, 180 mm and 100 mm in diameter, respectively, were fabricated and characterized experimentally with a modal shaker. The 180 mm prototype generated 120 mW from the electromagnetic system at 5 Hz and 0.8g, and 4.23 mW from the piezoelectric system at 20.2 Hz and 0.4g excitation acceleration. Finally, the power generation capabilities of the two prototypes were compared to other similar devices.

  3. Using Temporal Covariance of Motion and Geometric Features via Boosting for Human Fall Detection.

    Science.gov (United States)

    Ali, Syed Farooq; Khan, Reamsha; Mahmood, Arif; Hassan, Malik Tahir; Jeon, And Moongu

    2018-06-12

    Fall induced damages are serious incidences for aged as well as young persons. A real-time automatic and accurate fall detection system can play a vital role in timely medication care which will ultimately help to decrease the damages and complications. In this paper, we propose a fast and more accurate real-time system which can detect people falling in videos captured by surveillance cameras. Novel temporal and spatial variance-based features are proposed which comprise the discriminatory motion, geometric orientation and location of the person. These features are used along with ensemble learning strategy of boosting with J48 and Adaboost classifiers. Experiments have been conducted on publicly available standard datasets including Multiple Cameras Fall ( with 2 classes and 3 classes ) and UR Fall Detection achieving percentage accuracies of 99.2, 99.25 and 99.0, respectively. Comparisons with nine state-of-the-art methods demonstrate the effectiveness of the proposed approach on both datasets.

  4. [Walking with canes and forearm-crutches (author's transl)].

    Science.gov (United States)

    Bergmann, G; Kölbel, R; Rauschenbach, N; Rohlmann, A

    1978-02-01

    Partial weight bearing is frequently prescribed but cannot be controlled adequately. In a previous paper the change of forces at the hip joint as effected by a one sided cane was determined by instrumentation of the cane and a mechanical analysis of gait on a walkway. In the present study we looked at the conditions for control of partial weightbearing when two forearm crutches are used. Instrumented crutches and a forceplate were used. In walking with two forearm crutches the total of the ground reaction forces and the force pattern differ from those in free walking. The total of two crutch forces plus the force at the leg with partial weightbearing exceeds that caused by body weight alone. This is due to mass accelerations in a changed gait pattern. When the maximal leg force is reduced from 100% body weight to zero, the additional dynamic forces exceed those caused by body weight alone by 4%-19%. Only 2% of the additional dynamic forces act on the controlateral crutch while the rest is transmitted through the ipsilateral crutch. The crutch force pattern on the ipsilateral side depends more on individual gait characteristics than does that on the controlateral side. Load reduction is more pronounced in the late stages of the stand phase than in the early ones.

  5. Forearm arterial anatomy and flow characteristics: a prospective observational study.

    Science.gov (United States)

    Pancholy, Samir B; Heck, Laura A; Patel, Tejas

    2015-04-01

    Morphometric data on Caucasian radial and ulnar arteries are limited, with no data on flow interdependence in the forearm arterial circuit. A total of 250 upper extremities in 125 patients were evaluated. Ultrasonography was performed and radial and ulnar artery lumen diameters were measured. Ulnar artery (UA) was compressed at the level of the wrist, and flow parameters in radial artery (RA) were recorded using duplex Doppler ultrasound. Radial and ulnar artery diameters were comparable at the level of the distal forearm (RA = 2.03 ± 0.28 mm, UA = 2.07 ± 0.27 mm; P=.14). There was no significant difference in radial or ulnar artery diameter between the dominant upper extremity and the non-dominant upper extremity. Upon compression of the ulnar artery, radial artery velocity-time integral (VTI) increased from 8.4 ± 3.8 cm to 12.8 ± 5.5 cm, which was statistically significant (Pforearm is comparable to UA. RA-VTI and likely flow significantly increase by compression of the UA. The smaller the radial artery, the larger the increase in radial artery flow with ulnar compression.

  6. The posterolateral mid-forearm perforator flap: anatomical study and clinical application.

    Science.gov (United States)

    Zhuang, Yue-Hong; Lin, Jian; Fu, Fei-Huan; Cai, Zhen-De; Huang, Hui-Mei; Zheng, He-Ping

    2013-11-01

    Defects sustained at the distal forearm are common and pedicled perforator flaps have unique advantages in resurfacing it. The purpose of this study is to reappraise the anatomy of the perforator in the posterolateral aspect of the mid-forearm and present our clinical experience on using perforator flaps based on it for reconstruction of defects in the distal forearm. This study was divided into anatomical study and clinical application. In the anatomical study, 30 preserved upper limbs were used. Clinically, 11 patients with defects at the forearm underwent reconstruction with the posterolateral mid-forearm perforator flaps. The defects, ranging from 4.5 × 2.5 cm to 10.5 × 4.5 cm, were located at the dorsal aspect of the distal forearm in 6 cases and at the volar aspect of the distal forearm in 5 cases. Three patterns of the perforator were observed in the posterolateral aspect of the mid-forearm, which originated from the posterior interosseous artery, the proximal segment of the radial artery or the radial recurrent artery, and the middle segment of the radial artery, respectively. The perforator was located 11.8 ± 0.2 cm to 15.8 ± 0.4 cm inferior to the lateral humeral epicondyle. Clinically, flaps in 8 cases survived uneventfully, while the other 3 cases suffered mild marginal epidermal necrosis, which was cured with continuous dress changing. The location of the perforator at the posterolateral aspect of the mid-forearm is consistent; the posterolateral mid-forearm perforator flap is particularly suitable to cover defects in the distal one-third of the forearm. Copyright © 2013 Wiley Periodicals, Inc.

  7. Harvesting energy from the motion of human limbs: the design and analysis of an impact-based piezoelectric generator

    International Nuclear Information System (INIS)

    Renaud, Michael; Fiorini, Paolo; Van Hoof, Chris; Van Schaijk, Rob

    2009-01-01

    Vibration energy harvesters can replace batteries and serve as clean and renewable energy sources in low-consumption wireless applications. Harvesters delivering sufficient power for sensors operating in an industrial environment have been developed, but difficulties are encountered when the devices to be powered are located on the human body. In this case, classical harvester designs (resonant systems) are not adapted to the low-frequency and high-amplitude characteristics of the motion. For this reason, we propose in this paper an alternative design based on the impact of a moving mass on piezoelectric bending structures. A model of the system is presented and analysed in order to determine the parameters influencing the device performances in terms of energy harvesting. A prototype of the impact harvester is experimentally characterized: for a generator occupying approximately 25 cm 3 and weighing 60 g, an output power of 47 µW was measured across a resistive load when the device was rotated by 180° each second. 600 µW were obtained for a 10 Hz frequency and 10 cm amplitude linear motion. Further optimization of the piezoelectric transducer is possible, allowing a large increase in these values, bringing the power density for the two cases respectively to 10 and 120 µW cm −3

  8. Harvesting energy from the motion of human limbs: the design and analysis of an impact-based piezoelectric generator

    Science.gov (United States)

    Renaud, Michael; Fiorini, Paolo; van Schaijk, Rob; van Hoof, Chris

    2009-03-01

    Vibration energy harvesters can replace batteries and serve as clean and renewable energy sources in low-consumption wireless applications. Harvesters delivering sufficient power for sensors operating in an industrial environment have been developed, but difficulties are encountered when the devices to be powered are located on the human body. In this case, classical harvester designs (resonant systems) are not adapted to the low-frequency and high-amplitude characteristics of the motion. For this reason, we propose in this paper an alternative design based on the impact of a moving mass on piezoelectric bending structures. A model of the system is presented and analysed in order to determine the parameters influencing the device performances in terms of energy harvesting. A prototype of the impact harvester is experimentally characterized: for a generator occupying approximately 25 cm3 and weighing 60 g, an output power of 47 µW was measured across a resistive load when the device was rotated by 180° each second. 600 µW were obtained for a 10 Hz frequency and 10 cm amplitude linear motion. Further optimization of the piezoelectric transducer is possible, allowing a large increase in these values, bringing the power density for the two cases respectively to 10 and 120 µW cm-3.

  9. Intravenous regional anaesthesia (Bier's block) for pediatric forearm fractures in a pediatric emergency department-Experience from 2003 to 2014.

    Science.gov (United States)

    Chua, Ivan S Y; Chong, S L; Ong, Gene Y K

    2017-12-01

    pediatric forearm fractures in the Emergency Department with a formalised protocol to reduce and prevent any human errors that can potentially result in complications. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Analysis of Golf Swing Motion and Applied Loads on the Human Body Using Soft-Golf TM Club

    International Nuclear Information System (INIS)

    Kwak, Ki Young; So, Ha Ju; Kim, Sung Hyeon; Kim, Dong Wook; Kim, Nam Gyun

    2011-01-01

    The purpose of this study was to analyze the kinetic effect of Soft-golf TM instrument on the human body structure. To analyze the kinetic effect of Soft-golf TM instrument, Golf swing using Soft-golf TM instrument and regular golf instrument was captured. And then Upper limbs and lumbar joint torques was calculated via computer simulation. Five man participated this study. Subjects performed golf swing using a regular golf and Soft-golf TM instrument. Golf swing motion was captured using three position sensor, active infrared LED maker and force plate. Golf swing model was generated and simulated using ADAMS/LifeMOD program. As a results, joint torque during Soft-golf swing were lower than regular golf swing. Thus soft-golf swing have joint load lower than regular golf swing and contribute to reduce joint injury

  11. 78 FR 36308 - Proposed Information Collection (Elbow and Forearm Conditions Disability Benefits Questionnaire...

    Science.gov (United States)

    2013-06-17

    ... and Forearm Conditions Disability Benefits Questionnaire) Activity: Comment Request AGENCY: Veterans... Questionnaire)'' in any correspondence. During the comment period, comments may be viewed online through the... INFORMATION: Title: Elbow and Forearm Conditions Disability Benefits Questionnaire, VA Form 21-0960M-4. OMB...

  12. Clinical comparison of automatic, noninvasive measurements of blood pressure in the forearm and upper arm.

    Science.gov (United States)

    Schell, Kathleen; Bradley, Elisabeth; Bucher, Linda; Seckel, Maureen; Lyons, Denise; Wakai, Sandra; Bartell, Deborah; Carson, Elizabeth; Chichester, Melanie; Foraker, Teresa; Simpson, Kathleen

    2005-05-01

    When the upper arm (area from shoulder to elbow) is inaccessible and/or a standard-sized blood pressure cuff does not fit, some healthcare workers use the forearm to measure blood pressure. To compare automatic noninvasive measurements of blood pressure in the upper arm and forearm. A descriptive, correlational comparison study was conducted in the emergency department of a 1071-bed teaching hospital. Subjects were 204 English-speaking patients 6 to 91 years old in medically stable condition who had entered the department on foot or by wheelchair and who had no exclusions to using their left upper extremity. A Welch Allyn Vital Signs 420 series monitor was used to measure blood pressure in the left upper arm and forearm with the subject seated and the upper arm or forearm at heart level. Pearson r correlation coefficients between measurements in the upper arm and forearm were 0.88 for systolic blood pressure and 0.76 for diastolic blood pressure (P upper arm and forearm differed significantly (t = 2.07, P = .04). A Bland-Altman analysis indicated that the distances between the mean values and the limits of agreement for the 2 sites ranged from 15 mm Hg (mean arterial pressure) to 18.4 mm Hg (systolic pressure). Despite strict attention to correct cuff size and placement of the upper arm or forearm at heart level, measurements of blood pressure obtained noninvasively in the arm and forearm of seated patients in stable condition are not interchangeable.

  13. Estimation of Seismic Ground Motions and Attendant Potential Human Fatalities from Scenario Earthquakes on the Chishan Fault in Southern Taiwan

    Directory of Open Access Journals (Sweden)

    Kun-Sung Liu

    2017-01-01

    Full Text Available The purpose of this study is to estimate maximum ground motions in southern Taiwan as well as to assess potential human fatalities from scenario earthquakes on the Chishan active faults in this area. The resultant Shake Map patterns of maximum ground motion in a case of Mw 7.2 show the areas of PGA above 400 gals are located in the northeastern, central and northern parts of southwestern Kaohsiung as well as the southern part of central Tainan, as shown in the regions inside the yellow lines in the corresponding figure. Comparing cities with similar distances located in Tainan, Kaohsiung, and Pingtung to the Chishan fault, the cities in Tainan area have relatively greater PGA and PGV, due to large site response factors in Tainan area. Furthermore, seismic hazards in terms of PGA and PGV in the vicinity of the Chishan fault are not completely dominated by the Chishan fault. The main reason is that some areas located in the vicinity of the Chishan fault are marked with low site response amplification values from 0.55 - 1.1 and 0.67 - 1.22 for PGA and PGV, respectively. Finally, from estimation of potential human fatalities from scenario earthquakes on the Chishan active fault, it is noted that potential fatalities increase rapidly in people above age 45. Total fatalities reach a high peak in age groups of 55 - 64. Another to pay special attention is Kaohsiung City has more than 540 thousand households whose residences over 50 years old. In light of the results of this study, I urge both the municipal and central governments to take effective seismic hazard mitigation measures in the highly urbanized areas with a large number of old buildings in southern Taiwan.

  14. Two eyes, one vision: binocular motion perception in human visual cortex

    NARCIS (Netherlands)

    Barendregt, M.

    2016-01-01

    An important aspect of human vision is the fact that it is binocular, i.e. that we have two eyes. As a result, the brain nearly always receives two slightly different images of the same visual scene. Yet, we only perceive a single image and thus our brain has to actively combine the binocular visual

  15. Development and Control of a Robotic Exoskeleton for Shoulder, Elbow and Forearm Movement Assistance

    Directory of Open Access Journals (Sweden)

    Mohammad Habibur Rahman

    2012-01-01

    Full Text Available World health organization reports, annually more than 15 million people worldwide suffer a stroke and cardiovascular disease, among which 85% of stroke patients incur acute arm impairment, and 40% of victims are chronically impaired or permanently disabled. This results a burden on the families, communities and to the country as well. Rehabilitation programs are the main way to promote functional recovery in these individuals. Since the number of such cases is constantly growing and that the duration of treatment is long, an intelligent robot could significantly contribute to the success of these programs. We therefore developed a new 5DoFs robotic exoskeleton named MARSE-5 (motion assistive robotic-exoskeleton for superior extremity that supposed to be worn on the lateral side of upper arm to rehabilitate and ease the shoulder, elbow and forearm movements. This paper focused on the design, modeling, development and control of the proposed MARSE-5. To control the exoskeleton, a nonlinear sliding mode control (SMC technique was employed. In experiments, trajectory tracking that corresponds to typical passive rehabilitation exercises was carried out. Experimental results reveal that the controller is able to maneuver the MARSE-5 efficiently to track the desired trajectories.

  16. Wearable Sensors for eLearning of Manual Tasks: Using Forearm EMG in Hand Hygiene Training.

    Science.gov (United States)

    Kutafina, Ekaterina; Laukamp, David; Bettermann, Ralf; Schroeder, Ulrik; Jonas, Stephan M

    2016-08-03

    In this paper, we propose a novel approach to eLearning that makes use of smart wearable sensors. Traditional eLearning supports the remote and mobile learning of mostly theoretical knowledge. Here we discuss the possibilities of eLearning to support the training of manual skills. We employ forearm armbands with inertial measurement units and surface electromyography sensors to detect and analyse the user's hand motions and evaluate their performance. Hand hygiene is chosen as the example activity, as it is a highly standardized manual task that is often not properly executed. The World Health Organization guidelines on hand hygiene are taken as a model of the optimal hygiene procedure, due to their algorithmic structure. Gesture recognition procedures based on artificial neural networks and hidden Markov modeling were developed, achieving recognition rates of 98 . 30 % ( ± 1 . 26 % ) for individual gestures. Our approach is shown to be promising for further research and application in the mobile eLearning of manual skills.

  17. Finite element analysis of high modal dynamic responses of a composite floor subjected to human motion under passive live load

    Directory of Open Access Journals (Sweden)

    Arash Behnia

    Full Text Available Light weight and long span composite floors are common place in modern construction. A critical consequence of this application is undesired vibration which may cause excessive discomfort to occupants. This work investigates the composite floor vibration behavior of an existing building based on a comprehensive study of high modal dynamic responses, the range of which has been absent in previous studies and major analytical templates, of different panels under the influence of loads induced by human motion. The resulting fundamental natural frequency and vibration modes are first validated with respect to experimental and numerical evidences from literature. Departing from close correlation established in comparison, this study explores in detail the effects of intensity of passive live load as additional stationary mass due to crowd jumping as well as considering human structure interaction. From observation, a new approach in the simulation of passive live load through the consideration of human structure interaction and human body characteristics is proposed. It is concluded that higher vibration modes are essential to determine the minimum required modes and mass participation ratio in the case of vertical vibration. The results indicate the need to consider 30 modes of vibration to obtain all possible important excitations and thereby making third harmonic of load frequency available to excite the critical modes. In addition, presence of different intensities of passive live load on the composite floor showed completely different behavior in each particular panel associated with load location of panel and passive live load intensity. Furthermore, implementing human body characteristics in simulation causes an obvious increase in modal damping and hence better practicality and economical presentation can be achieved in structural dynamic behavior.

  18. Microvascular filtration is increased in the forearms of patients with breast cancer-related lymphedema

    DEFF Research Database (Denmark)

    Jensen, Mads Radmer; Simonsen, Lene; Karlsmark, Tonny

    2013-01-01

    -enhanced ultrasound; venous occlusion strain-gauge plethysmography; lower-body negative pressure; noninvasive blood pressure measurements; and skin (99m)Tc-pertechnetate clearance technique. Measurements were performed bilaterally and simultaneously in the forearms, enabling use of the nonedematous forearm...... relative microvascular volume, forearm blood flow, skin blood flow, or central or local sympathetic vascular reflexes. Forearm microvascular filtration is increased in patients with BCRL, and more so in the edematous arm. The vascular sympathetic control mechanisms seem to be preserved. We propose...... with unilateral BCRL, the following aspects of upper extremity peripheral circulation were examined: muscle relative microvascular volume; capillary filtration coefficient; central and local sympathetic vascular reflexes; skin blood flow; and forearm blood flow. These were studied via real-time, contrast...

  19. Muscle fatigue in relation to forearm pain and tenderness among professional computer users

    DEFF Research Database (Denmark)

    Thomsen, GF; Johnson, PW; Svendsen, Susanne Wulff

    2007-01-01

    ABSTRACT: BACKGROUND: To examine the hypothesis that forearm pain with palpation tenderness in computer users is associated with increased extensor muscle fatigue. METHODS: Eighteen persons with pain and moderate to severe palpation tenderness in the extensor muscle group of the right forearm...... response was not explained by differences in the MVC or body mass index. CONCLUSION: Computer users with forearm pain and moderate to severe palpation tenderness had diminished forearm extensor muscle fatigue response. Additional studies are necessary to determine whether this result reflects an adaptive...... and twenty gender and age matched referents without such complaints were enrolled from the Danish NUDATA study of neck and upper extremity disorders among technical assistants and machine technicians. Fatigue of the right forearm extensor muscles was assessed by muscle twitch forces in response to low...

  20. Effect of specific resistance training on forearm pain and work disability in industrial technicians: cluster randomised controlled trial

    DEFF Research Database (Denmark)

    Andersen, Lars Louis; Jakobsen, Markus D; Pedersen, Mogens Theisen

    2012-01-01

    To determine the effect of specific resistance training on forearm pain and work disability in industrial technicians.......To determine the effect of specific resistance training on forearm pain and work disability in industrial technicians....

  1. Increased sympathetic tone in forearm subcutaneous tissue in primary hypothyroidism

    DEFF Research Database (Denmark)

    Vagn Nielsen, H; Hasselström, K; Feldt-Rasmussen, U

    1987-01-01

    vasoconstriction normally seen after lowering the forearm 40 cm below heart level was absent since SBF only decreased by 4% (+/- 7%, P greater than 0.1) during these conditions. In head-up vertical position we noticed a diminished baroreceptor response as SBF at heart level was reduced by 11% (+/- 7%, P greater...... than 0.1) compared to supine position. After proximal local anaesthesia SBF increased by 351% (+/- 81%, P less than 0.01) and disclosed a normal vasoconstrictor response as SBF was reduced by 53% (+/- 5%, P less than 0.01) during arm lowering. Five of the treated patients were restudied.......02)). In conclusion sympathetic vasoconstrictor activity in adipose tissue is markedly increased in primary hypothyroidism. Sympathetic tone and arterial pressure are reduced during treatment....

  2. Recent progress of flexible and wearable strain sensors for human-motion monitoring

    Science.gov (United States)

    Ge, Gang; Huang, Wei; Shao, Jinjun; Dong, Xiaochen

    2018-01-01

    With the rapid development of human artificial intelligence and the inevitably expanding markets, the past two decades have witnessed an urgent demand for the flexible and wearable devices, especially the flexible strain sensors. Flexible strain sensors, incorporated the merits of stretchability, high sensitivity and skin-mountable, are emerging as an extremely charming domain in virtue of their promising applications in artificial intelligent realms, human-machine systems and health-care devices. In this review, we concentrate on the transduction mechanisms, building blocks of flexible physical sensors, subsequently property optimization in terms of device structures and sensing materials in the direction of practical applications. Perspectives on the existing challenges are also highlighted in the end. Project supported by the NNSF of China (Nos. 61525402, 61604071), the Key University Science Research Project of Jiangsu Province (No. 15KJA430006), and the Natural Science Foundation of Jiangsu Province (No. BK20161012).

  3. Elbow, forearm, wrist, and hand injuries among sport rock climbers.

    Science.gov (United States)

    Holtzhausen, L M; Noakes, T D

    1996-07-01

    Sport rock climbing with its repetitive high-torque movements in gaining the ascent of a rock face or wall, often in steep overhanging positions, is associated with a unique distribution and form of upper limb injuries. In this article, we review the biomechanical aspects of sport rock climbing and the types of injuries commonly encountered in the forearm, wrist, and hand regions of elite sport rock climbers. Because elbow, forearm, wrist, and hand injuries predominate, representing 62% of the total injuries encountered, these anatomical areas have been selected for review. The predominant source of data are the published work of Bollen et al. The remaining sources were obtained through electronic search of the Medline and Current Contents Databases (last searched May 1995). German and French articles were included in the search criteria. Only studies dealing with acute soft tissue and overuse injuries amongst sport rock climbers were selected. Data were extracted directly from the sourced articles. The following injuries have been described in detail with regard to their presentation, diagnosis, treatment, and prevention amongst sport rock climbers: medial epicondylitis, brachialis tendonitis, biceps brachii tendonitis, ulnar collateral ligament sprain of the elbow, carpal tunnel syndrome, digital flexor tendon pulley sheath tears, interphalangeal joint effusions, fixed flexion deformities of the interphalangeal joints, and collateral ligament tears of the interphalangeal joints. Many of the injuries are specific to the handhold types used by the rock climber. Accurate diagnosis and effective treatment of these unique injuries will be facilitated by a wider understanding of the biomechanical aspects of rock climbing and an awareness of the patterns and incidence of injuries in this sport.

  4. Molecular Dynamics Simulations of the STAS Domains of Rat Prestin and Human Pendrin Reveal Conformational Motions in Conserved Flexible Regions

    Directory of Open Access Journals (Sweden)

    Alok K. Sharma

    2014-02-01

    Full Text Available Background: Molecular dynamics (MD simulations provide valuable information on the conformational changes that accompany time-dependent motions in proteins. The reported crystal structure of rat prestin (PDB 3LLO is remarkable for an α1-α2 inter-helical angle that differs substantially from those observed in bacterial STAS domains of SulP anion transporters and anti-sigma factor antagonists. However, NMR data on the rat prestin STAS domain in solution suggests dynamic features at or near the α1-α2 helical region (Pasqualetto et al JMB, 2010. We therefore performed a 100 ns 300K MD simulation study comparing the STAS domains of rat prestin and (modeled human pendrin, to explore possible conformational flexibility in the region of the α1 and α2 helices. Methods: The conformation of the loop missing in the crystal structure of rat prestin STAS (11 amino acids between helix α1 and strand β3 was built using Modeller. MD simulations were performed with GROMACSv4.6 using GROMOS96 53a6 all-atom force field. Results: A subset of secondary structured elements of the STAS domains exhibits significant conformational changes during the simulation time course. The conformationally perturbed segments include the majority of loop regions, as well as the α1 and α2 helices. A significant decrease in the α1-α2 inter-helical angle observed across the simulation trajectory leads to closer helical packing at their C-termini. The end-simulation conformations of the prestin and pendrin STAS domains, including their decreased α1-α2 inter-helical angles, resemble more closely the packing of corresponding helices in the STAS structures of bacterial SulP transporters Rv1739c and ychM, as well as those of the anti-sigma factor antagonists. Several structural segments of the modeled human pendrin STAS domain exhibit larger atomic motions and greater conformational deviations than the corresponding regions of rat prestin, predicting that the human pendrin STAS

  5. Open source platform for collaborative construction of wearable sensor datasets for human motion analysis and an application for gait analysis.

    Science.gov (United States)

    Llamas, César; González, Manuel A; Hernández, Carmen; Vegas, Jesús

    2016-10-01

    Nearly every practical improvement in modeling human motion is well founded in a properly designed collection of data or datasets. These datasets must be made publicly available for the community could validate and accept them. It is reasonable to concede that a collective, guided enterprise could serve to devise solid and substantial datasets, as a result of a collaborative effort, in the same sense as the open software community does. In this way datasets could be complemented, extended and expanded in size with, for example, more individuals, samples and human actions. For this to be possible some commitments must be made by the collaborators, being one of them sharing the same data acquisition platform. In this paper, we offer an affordable open source hardware and software platform based on inertial wearable sensors in a way that several groups could cooperate in the construction of datasets through common software suitable for collaboration. Some experimental results about the throughput of the overall system are reported showing the feasibility of acquiring data from up to 6 sensors with a sampling frequency no less than 118Hz. Also, a proof-of-concept dataset is provided comprising sampled data from 12 subjects suitable for gait analysis. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Highly flexible self-powered sensors based on printed circuit board technology for human motion detection and gesture recognition.

    Science.gov (United States)

    Fuh, Yiin-Kuen; Ho, Hsi-Chun

    2016-03-04

    In this paper, we demonstrate a new integration of printed circuit board (PCB) technology-based self-powered sensors (PSSs) and direct-write, near-field electrospinning (NFES) with polyvinylidene fluoride (PVDF) micro/nano fibers (MNFs) as source materials. Integration with PCB technology is highly desirable for affordable mass production. In addition, we systematically investigate the effects of electrodes with intervals in the range of 0.15 mm to 0.40 mm on the resultant PSS output voltage and current. The results show that at a strain of 0.5% and 5 Hz, a PSS with a gap interval 0.15 mm produces a maximum output voltage of 3 V and a maximum output current of 220 nA. Under the same dimensional constraints, the MNFs are massively connected in series (via accumulation of continuous MNFs across the gaps ) and in parallel (via accumulation of parallel MNFs on the same gap) simultaneously. Finally, encapsulation in a flexible polymer with different interval electrodes demonstrated that electrical superposition can be realized by connecting MNFs collectively and effectively in serial/parallel patterns to achieve a high current and high voltage output, respectively. Further improvement in PSSs based on the effect of cooperativity was experimentally realized by rolling-up the device into a cylindrical shape, resulting in a 130% increase in power output due to the cooperative effect. We assembled the piezoelectric MNF sensors on gloves, bandages and stockings to fabricate devices that can detect different types of human motion, including finger motion and various flexing and extensions of an ankle. The firmly glued PSSs were tested on the glove and ankle respectively to detect and harvest the various movements and the output voltage was recorded as ∼1.5 V under jumping movement (one PSS) and ∼4.5 V for the clenched fist with five fingers bent concurrently (five PSSs). This research shows that piezoelectric MNFs not only have a huge impact on harvesting various external

  7. Highly flexible self-powered sensors based on printed circuit board technology for human motion detection and gesture recognition

    Science.gov (United States)

    Fuh, Yiin-Kuen; Ho, Hsi-Chun

    2016-03-01

    In this paper, we demonstrate a new integration of printed circuit board (PCB) technology-based self-powered sensors (PSSs) and direct-write, near-field electrospinning (NFES) with polyvinylidene fluoride (PVDF) micro/nano fibers (MNFs) as source materials. Integration with PCB technology is highly desirable for affordable mass production. In addition, we systematically investigate the effects of electrodes with intervals in the range of 0.15 mm to 0.40 mm on the resultant PSS output voltage and current. The results show that at a strain of 0.5% and 5 Hz, a PSS with a gap interval 0.15 mm produces a maximum output voltage of 3 V and a maximum output current of 220 nA. Under the same dimensional constraints, the MNFs are massively connected in series (via accumulation of continuous MNFs across the gaps ) and in parallel (via accumulation of parallel MNFs on the same gap) simultaneously. Finally, encapsulation in a flexible polymer with different interval electrodes demonstrated that electrical superposition can be realized by connecting MNFs collectively and effectively in serial/parallel patterns to achieve a high current and high voltage output, respectively. Further improvement in PSSs based on the effect of cooperativity was experimentally realized by rolling-up the device into a cylindrical shape, resulting in a 130% increase in power output due to the cooperative effect. We assembled the piezoelectric MNF sensors on gloves, bandages and stockings to fabricate devices that can detect different types of human motion, including finger motion and various flexing and extensions of an ankle. The firmly glued PSSs were tested on the glove and ankle respectively to detect and harvest the various movements and the output voltage was recorded as ∼1.5 V under jumping movement (one PSS) and ∼4.5 V for the clenched fist with five fingers bent concurrently (five PSSs). This research shows that piezoelectric MNFs not only have a huge impact on harvesting various external

  8. Lubrication of the Human Anklejoint in Walking with the Synovial Fluid Filtrated by the Cartilage with the Surface Zone Worn-out:Steady Pure Sliding Motion

    Czech Academy of Sciences Publication Activity Database

    Hlaváček, Miroslav

    1999-01-01

    Roč. 32, č. 10 (1999), s. 1059-1069 ISSN 0021-9290 Keywords : biphasic articular cartilage * biphasic synovial fluid * boooundary lubrication * human ankle joint * sliding motion Subject RIV: FI - Traumatology, Orthopedics Impact factor: 1.536, year: 1999

  9. Blood pressure measurement in obese patients: comparison between upper arm and forearm measurements.

    Science.gov (United States)

    Pierin, Angela M G; Alavarce, Débora C; Gusmão, Josiane L; Halpern, Alfredo; Mion, Décio

    2004-06-01

    It is well known that blood pressure measurement with a standard 12-13 cm wide cuff is erroneous for large arms. To compare arm blood pressure measurements with an appropriate cuff and forearm blood pressure measurements (BPM) with a standard cuff, and both measurements by the Photopletismography (Finapres) method. One hundred and twenty-nine obese patients were studied (body mass index=40+/-7 kg/m2). The patients had three arm BPM taken by an automatic oscillometric device using an appropriate cuff and three forearm BPM with a standard cuff in the sitting position after a five-minute rest. Data were analysed by the analysis of variance. The correction values were obtained by the linear regression test. Systolic and diastolic arm BPM with an appropriate cuff were significantly lower (pforearm BPM with a standard cuff. The measurements obtained by Finapres were significantly lower (pforearm systolic and diastolic blood pressures and upper arm diastolic blood pressure. The equation to correct BPM in forearm in obese patients with arm circumference between 32-44 cm was: systolic BPM=33.2+/-0.68 x systolic forearm BPM, and diastolic BPM=25.2+0.59 x forearm diastolic BPM. This study showed that forearm blood pressure measurement overestimates the values of arm blood pressure measurement. In addition, it is possible to correct forearm BPM with an equation.

  10. The transverse force experienced by the radial head during axial loading of the forearm: A cadaveric study.

    Science.gov (United States)

    Orbay, Jorge L; Mijares, Michael R; Berriz, Cecilia G

    2016-01-01

    When designing a radial head replacement, the magnitude and direction of forces applied across the proximal radio-ulnar joint (PRUJ) and the radiocapitellar joint must be included. These designs often focus on axial loads transmitted to the radial head by the capitellum; however, the radial head also bears a significant transverse force at the PRUJ. Load transmission by the central band of the interosseous ligament induces a force component in a lateral direction perpendicular to the axis of the limb, which is borne by the articular surfaces of the proximal and distal radio-ulnar joints. The objective of this study is to establish the relationship between distally applied axial forces and proximal transverse reaction forces. Five cadaveric, human forearms with intact interosseous membranes were used to measure the magnitude of transversely-directed forces experienced by the radial head during axial loading of the forearm at the lunate fossa. A Mark-10 test stand applied a gradual and continuous axial load on the articular surface of the distal radius. A Mark-10 force gauge measured the resultant transverse force experienced by the radial head in the proximal radioulnar joint. Classical mechanics and static force analysis were applied in order to predict lateral force values that would occur when the interosseous ligament is treated as the major load transmitter between the radius and ulna. Acquired data show that the radial head bears a force in the transverse direction that averages 18% (SD 3.89%) in magnitude of the axial force applied at the wrist. This figure is in close accordance with the predicted value of 22% that was calculated by way of free-body plotting. Physiologic forearm loading results in a clinically significant transverse force component transmitted through the interosseous ligament complex. The existence of transverse forces in the human forearm may explain clinical problems seen after radial head resection and suggest that radial head implants

  11. Human Motion Tracking and Glove-Based User Interfaces for Virtual Environments in ANVIL

    Science.gov (United States)

    Dumas, Joseph D., II

    2002-01-01

    The Army/NASA Virtual Innovations Laboratory (ANVIL) at Marshall Space Flight Center (MSFC) provides an environment where engineers and other personnel can investigate novel applications of computer simulation and Virtual Reality (VR) technologies. Among the many hardware and software resources in ANVIL are several high-performance Silicon Graphics computer systems and a number of commercial software packages, such as Division MockUp by Parametric Technology Corporation (PTC) and Jack by Unigraphics Solutions, Inc. These hardware and software platforms are used in conjunction with various VR peripheral I/O (input / output) devices, CAD (computer aided design) models, etc. to support the objectives of the MSFC Engineering Systems Department/Systems Engineering Support Group (ED42) by studying engineering designs, chiefly from the standpoint of human factors and ergonomics. One of the more time-consuming tasks facing ANVIL personnel involves the testing and evaluation of peripheral I/O devices and the integration of new devices with existing hardware and software platforms. Another important challenge is the development of innovative user interfaces to allow efficient, intuitive interaction between simulation users and the virtual environments they are investigating. As part of his Summer Faculty Fellowship, the author was tasked with verifying the operation of some recently acquired peripheral interface devices and developing new, easy-to-use interfaces that could be used with existing VR hardware and software to better support ANVIL projects.

  12. Free radial forearm adiposo-fascial flap for inferior maxillectomy defect reconstruction

    Science.gov (United States)

    Thankappan, Krishnakumar; Trivedi, Nirav P.; Sharma, Mohit; Kuriakose, Moni A.; Iyer, Subramania

    2009-01-01

    A free radial forearm fascial flap has been described for intraoral reconstruction. Adiposo-fascial flap harvesting involves few technical modifications from the conventional radial forearm fascio-cutaneous free flap harvesting. We report a case of inferior maxillectomy defect reconstruction in a 42-year-old male with a free radial forearm adiposo-fascial flap with good aesthetic and functional outcome with minimal primary and donor site morbidity. The technique of raising the flap and closing the donor site needs to be meticulous in order to achieve good cosmetic and functional outcome. PMID:19881028

  13. Free radial forearm adiposo-fascial flap for inferior maxillectomy defect reconstruction

    Directory of Open Access Journals (Sweden)

    Thankappan Krishnakumar

    2009-01-01

    Full Text Available A free radial forearm fascial flap has been described for intraoral reconstruction. Adiposo-fascial flap harvesting involves few technical modifications from the conventional radial forearm fascio-cutaneous free flap harvesting. We report a case of inferior maxillectomy defect reconstruction in a 42-year-old male with a free radial forearm adiposo-fascial flap with good aesthetic and functional outcome with minimal primary and donor site morbidity. The technique of raising the flap and closing the donor site needs to be meticulous in order to achieve good cosmetic and functional outcome.

  14. Clinical anatomy of the donor zone of venous flaps of forearm

    Directory of Open Access Journals (Sweden)

    O. S. Kurochkina

    2012-01-01

    Full Text Available The variant anatomy of saphenous veins of forearm in the zones of venous flap rising remains unstudied yet, as well as the influence of the valve apparatus of saphenous veins on the arterial perfusion of venous flaps. The paper studies the variant anatomy of saphenous veins of the upper third of the volar surface of forearm. Two versions of saphenous veins are revealed: major (axial and retiform. It is found experimentally that the valve apparatus of saphenous veins does not influence considerably the arterial perfusion of venous flaps of forearm.

  15. Maternal dietary patterns during pregnancy in relation to offspring forearm fractures

    DEFF Research Database (Denmark)

    Petersen, Sesilje Elise Bondo; Rasmussen, Morten Arendt; Olsen, Sjurdur F

    2015-01-01

    Limited evidence exists for an association between maternal diet during pregnancy and offspring bone health. In a prospective study, we examined the association between dietary patterns in mid-pregnancy and offspring forearm fractures. In total, 101,042 pregnancies were recruited to the Danish...... associated with offspring forearm fractures (p = 0.02). In the large prospective DNBC high mid-pregnancy consumption of Western diet and artificially sweetened soft drinks, respectively, indicated positive associations with offspring forearm fractures, which provides interesting hypotheses for future...

  16. Reversed Palmaris Longus Muscle Causing Volar Forearm Pain and Ulnar Nerve Paresthesia.

    Science.gov (United States)

    Bhashyam, Abhiram R; Harper, Carl M; Iorio, Matthew L

    2017-04-01

    A case of volar forearm pain associated with ulnar nerve paresthesia caused by a reversed palmaris longus muscle is described. The patient, an otherwise healthy 46-year-old male laborer, presented after a previous unsuccessful forearm fasciotomy for complaints of exercise exacerbated pain affecting the volar forearm associated with paresthesia in the ulnar nerve distribution. A second decompressive fasciotomy was performed revealing an anomalous "reversed" palmaris longus, with the muscle belly located distally. Resection of the anomalous muscle was performed with full relief of pain and sensory symptoms. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  17. The role of ultrasound and magnetic resonance imaging in the evaluation of the forearm interosseous membrane. A review

    International Nuclear Information System (INIS)

    Rodriguez-Martin, Juan; Pretell-Mazzini, Juan

    2011-01-01

    The interosseous membrane of the forearm is an important structure to consider in cases of elbow and forearm trauma; it can be injured after elbow or forearm fractures, leading to longitudinal forearm instability. Diagnosis of interosseous membrane injuries is challenging, and failure in diagnosis may result in poor clinical outcomes and complications. Magnetic resonance imaging and ultrasound have shown to be valuable methods for the evaluation of this important structure. Both techniques have advantages and limitations, and its use should be adapted to each specific clinical scenario. This article presents an up-to-date literature review regarding the use of ultrasound and magnetic resonance imaging in the forearm interosseous membrane evaluation. (orig.)

  18. The role of ultrasound and magnetic resonance imaging in the evaluation of the forearm interosseous membrane. A review

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez-Martin, Juan [Infanta Leonor University Hospital, Trauma and Orthopaedics, Shoulder and Elbow Unit, Madrid (Spain); Pretell-Mazzini, Juan [The Children' s Hospital of Philadelphia, Pediatric Orthopaedic Fellow, Division of Orthopaedic Surgery, Philadelphia, PA (United States)

    2011-12-15

    The interosseous membrane of the forearm is an important structure to consider in cases of elbow and forearm trauma; it can be injured after elbow or forearm fractures, leading to longitudinal forearm instability. Diagnosis of interosseous membrane injuries is challenging, and failure in diagnosis may result in poor clinical outcomes and complications. Magnetic resonance imaging and ultrasound have shown to be valuable methods for the evaluation of this important structure. Both techniques have advantages and limitations, and its use should be adapted to each specific clinical scenario. This article presents an up-to-date literature review regarding the use of ultrasound and magnetic resonance imaging in the forearm interosseous membrane evaluation. (orig.)

  19. Perceptual learning of motion direction discrimination with suppressed and unsuppressed MT in humans: an fMRI study.

    Directory of Open Access Journals (Sweden)

    Benjamin Thompson

    Full Text Available The middle temporal area of the extrastriate visual cortex (area MT is integral to motion perception and is thought to play a key role in the perceptual learning of motion tasks. We have previously found, however, that perceptual learning of a motion discrimination task is possible even when the training stimulus contains locally balanced, motion opponent signals that putatively suppress the response of MT. Assuming at least partial suppression of MT, possible explanations for this learning are that 1 training made MT more responsive by reducing motion opponency, 2 MT remained suppressed and alternative visual areas such as V1 enabled learning and/or 3 suppression of MT increased with training, possibly to reduce noise. Here we used fMRI to test these possibilities. We first confirmed that the motion opponent stimulus did indeed suppress the BOLD response within hMT+ compared to an almost identical stimulus without locally balanced motion signals. We then trained participants on motion opponent or non-opponent stimuli. Training with the motion opponent stimulus reduced the BOLD response within hMT+ and greater reductions in BOLD response were correlated with greater amounts of learning. The opposite relationship between BOLD and behaviour was found at V1 for the group trained on the motion-opponent stimulus and at both V1 and hMT+ for the group trained on the non-opponent motion stimulus. As the average response of many cells within MT to motion opponent stimuli is the same as their response to non-directional flickering noise, the reduced activation of hMT+ after training may reflect noise reduction.

  20. Sonographic identification of peripheral nerves in the forearm

    Directory of Open Access Journals (Sweden)

    Saundra A Jackson

    2016-01-01

    Full Text Available Background: With the growing utilization of ultrasonography in emergency medicine combined with the concern over adequate pain management in the emergency department (ED, ultrasound guidance for peripheral nerve blockade in ED is an area of increasing interest. The medical literature has multiple reports supporting the use of ultrasound guidance in peripheral nerve blocks. However, to perform a peripheral nerve block, one must first be able to reliably identify the specific nerve before the procedure. Objective: The primary purpose of this study is to describe the number of supervised peripheral nerve examinations that are necessary for an emergency medicine physician to gain proficiency in accurately locating and identifying the median, radial, and ulnar nerves of the forearm via ultrasound. Methods: The proficiency outcome was defined as the number of attempts before a resident is able to correctly locate and identify the nerves on ten consecutive examinations. Didactic education was provided via a 1 h lecture on forearm anatomy, sonographic technique, and identification of the nerves. Participants also received two supervised hands-on examinations for each nerve. Count data are summarized using percentages or medians and range. Random effects negative binomial regression was used for modeling panel count data. Results: Complete data for the number of attempts, gender, and postgraduate year (PGY training year were available for 38 residents. Nineteen males and 19 females performed examinations. The median PGY year in practice was 3 (range 1-3, with 10 (27% in year 1, 8 (22% in year 2, and 19 (51% in year 3 or beyond. The median number (range of required supervised attempts for radial, median, and ulnar nerves was 1 (0-12, 0 (0-10, and 0 (0-17, respectively. Conclusion: We can conclude that the maximum number of supervised attempts to achieve accurate nerve identification was 17 (ulnar, 12 (radial, and 10 (median in our study. The only

  1. Aristotle, Motion, and Rhetoric.

    Science.gov (United States)

    Sutton, Jane

    Aristotle rejects a world vision of changing reality as neither useful nor beneficial to human life, and instead he reaffirms both change and eternal reality, fuses motion and rest, and ends up with "well-behaved" changes. This concept of motion is foundational to his world view, and from it emerges his theory of knowledge, philosophy of…

  2. Mechanical properties and motion of the cupula of the human semicircular canal.

    Science.gov (United States)

    Selva, Pierre; Oman, Charles M; Stone, Howard A

    2009-01-01

    The mathematical model for the dynamics of the cupula-endolymph system of the inner ear semicircular canal, as elaborated by numerous investigators, remains a foundational tool in all of vestibular physiology. Most models represent the cupula as a linear spring-like element of stiffness K=DeltaP/DeltaV, where DeltaV is the volume displaced upon application of a pressure difference DeltaP. The parameter K directly influences the long time constant of the cupula-endolymph system. Given estimates of K based on experiments, we use thick and thin bending membrane theory, and also finite-element simulations based on more realistic cupula morphologies, to estimate the human cupula's Young's modulus E approximately 5.4 Pa. We show that for a model morphology, thick bending membrane theory and finite-element predictions are in good agreement, and conclude that the morphology of the attachment of the cupula to the slope of the crista should not greatly influence the volume displacement. We note, however, that other biological materials with very low E are hydrogels that have significant viscoelastic properties. Experiments to directly measure E and investigate potential viscoelastic behavior ultimately may be needed. In addition, based on experimental images we study two other different shapes for the cupula and quantify their impact on the deflection of the cupula. We also use a three-dimensional finite-element model to analyze both the shear strain distribution and its time evolution near the sensory epithelium. We conclude that stimulation of sensory hair cells probably begins at the centre of the crista and spreads toward the periphery of the cupula and down the sides of the crista. Thus, spatio-temporal variations in the shearing stimulus are predicted to impact subsequent transduction and encoding. Finally, modeling the fluid-filled vertical channels believed to lie within the cupula, we investigate the impact of different tube diameters on the transverse displacement

  3. Automatic motion correction for in vivo human skin optical coherence tomography angiography through combined rigid and nonrigid registration

    Science.gov (United States)

    Wei, David Wei; Deegan, Anthony J.; Wang, Ruikang K.

    2017-06-01

    When using optical coherence tomography angiography (OCTA), the development of artifacts due to involuntary movements can severely compromise the visualization and subsequent quantitation of tissue microvasculatures. To correct such an occurrence, we propose a motion compensation method to eliminate artifacts from human skin OCTA by means of step-by-step rigid affine registration, rigid subpixel registration, and nonrigid B-spline registration. To accommodate this remedial process, OCTA is conducted using two matching all-depth volume scans. Affine transformation is first performed on the large vessels of the deep reticular dermis, and then the resulting affine parameters are applied to all-depth vasculatures with a further subpixel registration to refine the alignment between superficial smaller vessels. Finally, the coregistration of both volumes is carried out to result in the final artifact-free composite image via an algorithm based upon cubic B-spline free-form deformation. We demonstrate that the proposed method can provide a considerable improvement to the final en face OCTA images with substantial artifact removal. In addition, the correlation coefficients and peak signal-to-noise ratios of the corrected images are evaluated and compared with those of the original images, further validating the effectiveness of the proposed method. We expect that the proposed method can be useful in improving qualitative and quantitative assessment of the OCTA images of scanned tissue beds.

  4. Therapeutic effect of forearm low level light treatment on blood flow, oxygenation, and oxygen consumption

    Science.gov (United States)

    Wang, Pengbo; Sun, Jiajing; Meng, Lingkang; Li, Zebin; Li, Ting

    2018-02-01

    Low level light/laser therapy (LLLT) is considered as a novel, non-invasive, and potential therapy in a variety of psychological and physical conditions, due to its effective intricate photobiomodulation. The mechanism of LLLT is that when cells are stimulated by photons, mitochondria produce a large quantity of ATP, which accelerates biochemical responses in the cell. It is of great significance to gain a clear insight into the change or interplay of various physiological parameters. In this study, we used functional near-infrared spectroscopy (fNIRS) and venous-occlusion plethysmography to measure the LLLT-induced changes in blood flow, oxygenation, and oxygen consumption in human forearms in vivo. Six healthy human participants (4 males and 2 females) were administered with 810-nm light emitted by LED array in ten minutes and blood flow, oxygenation and oxygen consumption were detected in the entire experiment. We found that LLLT induced an increase of blood flow and oxygen consumption on the treated site. Meanwhile, LLLT took a good role in promoting oxygenation of regional tissue, which was indicated by a significant increase of oxygenated hemoglobin concentration (Δ[HbO2]), a nearly invariable deoxygenated hemoglobin concentration (Δ[Hb]) and a increase of differential hemoglobin concentration (Δ[HbD] = Δ[HbO2] - Δ[Hb]). These results not only demonstrate enormous potential of LLLT, but help to figure out mechanisms of photobiomodulation.

  5. Quality control and standardization of forearm X-ray osteodensitometry

    International Nuclear Information System (INIS)

    Boyanov, M.

    2000-01-01

    Quality control (QC) has an essential practical bearing on the proper function of the equipment used for bone density measurement. Special attention is likewise focused on the issue of standardization of the results afforded by different osteodensitometry instruments. It is the purpose of the study to assay QC of a single-energy x-ray forearm osteodensitometry unit DTX-100 covering a 3 year period, and compare the data on bone mineral density (BMD) produced by three different devices. Long-term BMD reproducibility in vitro, expressed as coefficient of variation, amounts to 0.55 per cent. Except for a two week period, no deviation from the normal function of the instrument is documented. Failing to comply with the manufacturer's instructions may discredit QC efficacy. On comparative assessment of the results produced by different osteodensitometers, differences in vivo may reach up to 1.2 standard deviation. Definite regions of special interest, feasible for comparison, are recommended. In conclusion special emphasis is laid on the necessity of performing through QC, measurement results standardization and accreditation of a reference osteodensitometry center

  6. [Kinematics of the triangular fibrocartilage complex during forearm rotation in vivo].

    Science.gov (United States)

    Xu, Jing; Tang, Jin-bo; Jia, Zhong-zheng; Xie, Ren-guo

    2009-11-01

    To investigate three-dimensional kinematics of the superficial and deep portion of triangular fibrocartilage complex (TFCC) in different parts of the forearm rotation. Six wrists of 6 volunteers were used to obtain CT scans at different positions of the wrist. The wrists were scanned from 90 degrees of pronation to 90 degrees of supination at an interval of 30 degrees. The 3-dimensional radius and ulna were reconstructed with customized software and changes in length of the superficial and deep portion of TFCC during forearm rotation. In forearm pronation, the superficial dorsal portion and the deep palmar portion of the TFCC were tight. While the superficial palmar portion and the deep dorsal potion of the TFCC were lax. In supination, the changes in length of all these fibers were reverse. In forearm rotation one portion fibers of dorsal TFCC and one portion fibers of palmar TFCC are tight, and this mechanism controls stability during DRUJ rotation.

  7. Cut-off values of distal forearm bone density for the diagnosis of ...

    African Journals Online (AJOL)

    2011-09-15

    Sep 15, 2011 ... Cost and Burden of Osteoporosis in 2011), released ... Women who had a forearm BMD below this threshold were ~10 times more likely to have osteoporosis of the spine. ..... assessing bone density, cost and effectiveness.

  8. Intersection syndrome: MR imaging with anatomic comparison of the distal forearm

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Jose E. de; Kim, Hyun-Jin; Albertotti, Flavio; Resnick, Donald [University of California, San Diego, VA San Diego Healthcare System, San Diego (United States)

    2004-11-01

    To correlate the anatomic and MR imaging characteristics of the area of intersection of the first and the second dorsal extensor tendon compartments (DETC) in the distal forearm in an attempt to improve the design of MR imaging protocols used for the evaluation of intersection syndrome. Ten forearms of nine cadavers underwent MR imaging in the axial and sagittal-oblique planes before and after tenography with direct injection of a gadolinium-containing contrast agent into the first DETC in four forearms, the second DETC in four forearms, and both compartments in the remaining two forearms. The area of intersection between the first and second DETC was identified in each case as well as its distance from Lister's tubercle. Subsequently all forearms were sectioned in the axial (8 forearms) or sagittal-oblique planes (2 remaining forearms) to parallel the imaging planes. Detailed examination of each of the anatomic slices was performed in a search for anatomic variations and for possible anatomic connections of the tendons sheaths. One forearm was dissected to identify the area of intersection. The area of intersection between the first and second DETC occurred between 3.5 cm and 4.8 cm (mean 4.18 cm) proximal to Lister's tubercle. After tenography, gadolinium solution was noted in the third DETC in two of four specimens in which the second DETC was injected and in one of two specimens in which both the first and second DETC were injected. Extension of the gadolinium solution between the first and second DETC was noted during isolated injections of either compartment, although this finding may have related to iatrogenic injection effects. The axial plane was the most valuable for assessment of the area of intersection of the first and second DETC. MR imaging is a noninvasive method that can be used for the evaluation of distal forearm and wrist pain. Standard wrist protocols do not include the area of intersection between the first and second DETC and, in

  9. Intersection syndrome: MR imaging with anatomic comparison of the distal forearm

    International Nuclear Information System (INIS)

    Lima, Jose E. de; Kim, Hyun-Jin; Albertotti, Flavio; Resnick, Donald

    2004-01-01

    To correlate the anatomic and MR imaging characteristics of the area of intersection of the first and the second dorsal extensor tendon compartments (DETC) in the distal forearm in an attempt to improve the design of MR imaging protocols used for the evaluation of intersection syndrome. Ten forearms of nine cadavers underwent MR imaging in the axial and sagittal-oblique planes before and after tenography with direct injection of a gadolinium-containing contrast agent into the first DETC in four forearms, the second DETC in four forearms, and both compartments in the remaining two forearms. The area of intersection between the first and second DETC was identified in each case as well as its distance from Lister's tubercle. Subsequently all forearms were sectioned in the axial (8 forearms) or sagittal-oblique planes (2 remaining forearms) to parallel the imaging planes. Detailed examination of each of the anatomic slices was performed in a search for anatomic variations and for possible anatomic connections of the tendons sheaths. One forearm was dissected to identify the area of intersection. The area of intersection between the first and second DETC occurred between 3.5 cm and 4.8 cm (mean 4.18 cm) proximal to Lister's tubercle. After tenography, gadolinium solution was noted in the third DETC in two of four specimens in which the second DETC was injected and in one of two specimens in which both the first and second DETC were injected. Extension of the gadolinium solution between the first and second DETC was noted during isolated injections of either compartment, although this finding may have related to iatrogenic injection effects. The axial plane was the most valuable for assessment of the area of intersection of the first and second DETC. MR imaging is a noninvasive method that can be used for the evaluation of distal forearm and wrist pain. Standard wrist protocols do not include the area of intersection between the first and second DETC and, in those cases

  10. Control and postural thixotropy of the forearm muscles: changes caused by cold.

    OpenAIRE

    Lakie, M; Walsh, E G; Wright, G W

    1986-01-01

    The forearm was cooled in water at 5-10 degrees C while wrist biodynamics were investigated. Pronounced loosening following a perturbation (thixotropy) was no longer seen. The wrist became stiffer for large or moderate but not small movements; EMG activity did not increase. Cooling the wrist alone, or opposite forearm, was without effect. The ability to make rapid reciprocating movements was reduced and muscle relaxation time was increased. Single movements were not affected.

  11. Clinical anatomy of the donor zone of venous flaps of forearm

    OpenAIRE

    O. S. Kurochkina

    2012-01-01

    The variant anatomy of saphenous veins of forearm in the zones of venous flap rising remains unstudied yet, as well as the influence of the valve apparatus of saphenous veins on the arterial perfusion of venous flaps. The paper studies the variant anatomy of saphenous veins of the upper third of the volar surface of forearm. Two versions of saphenous veins are revealed: major (axial) and retiform. It is found experimentally that the valve apparatus of saphenous veins does not influence consid...

  12. Surgical trainees neuropraxia? An unusual case of compression of the lateral cutaneous nerve of the forearm.

    LENUS (Irish Health Repository)

    Seoighe, D M

    2010-09-01

    Compression of the lateral cutaneous nerve of the forearm is an uncommon diagnosis but has been associated with strenuous upper limb activity. We report the unique case of a 32-year-old male orthopaedic trainee who suffered this nerve palsy as a result of prolonged elbow extension and forearm pronation while the single assistant during a hip resurfacing procedure. Conservative measures were sufficient for sensory recovery to be clinically detectable after 12 weeks.

  13. Long-term results of forearm lengthening and deformity correction by the Ilizarov method.

    Science.gov (United States)

    Orzechowski, Wiktor; Morasiewicz, Leszek; Krawczyk, Artur; Dragan, Szymon; Czapiński, Jacek

    2002-06-30

    Background. Shortening and deformity of the forearm is most frequently caused by congenital disorders or posttraumatic injury. Given its complex anatomy and biomechanics, the forearm is clearly the most difficult segment for lengthening and deformity correction. Material and methods. We analyzed 16 patients with shortening and deformity of the forearm, treated surgically, using the Ilizarov method in our Department from 1989 to 2001. in 9 cases 1-stage surgery was sufficient, while the remaining 7 patients underwent 2-5 stages of treatment. At total of 31 surgical operations were performed. The extent of forearm shortening ranged from 1,5 to 14,5 cm (5-70%). We development a new fixator based on Schanz half-pins. Results. The length of forearm lengthening per operative stage averaged 2,35 cm. the proportion of lengthening ranged from 6% to 48% with an average of 18,3%. The mean lengthening index was 48,15 days/cm. the per-patient rate of complications was 88% compared 45% per stage of treatment, mostly limited rotational mobility and abnormal consolidation of regenerated bone. Conclusions. Despite the high complication rate, the Ilizarov method is the method of choice for patients with forearm shortenings and deformities. Treatment is particularly indicated in patients with shortening caused by disproportionate length of the ulnar and forearm bones. Treatment should be managed so as cause the least possible damage to arm function, even at the cost of limited lengthening. Our new stabilizer based on Schanz half-pins makes it possible to preserve forearm rotation.

  14. Inconsistency between simultaneous blood pressure measurements in the arm, forearm, and leg in anesthetized children.

    Science.gov (United States)

    Keidan, Ilan; Sidi, Avner; Ben-Menachem, Erez; Tene, Yael; Berkenstadt, Haim

    2014-02-01

    To determine the accuracy and precision of simultaneous noninvasive blood pressure (NIBP) measurement in the arm, forearm, and ankle in anesthetized children. Prospective, randomized study. University medical center. 101 ASA physical status 1 and 2 children (aged 1-8 yrs) scheduled for elective surgery with general anesthesia. Simultaneous NIBP measurements were recorded at the arm, forearm, and ankle at 5-minute intervals. The systolic blood pressure difference between the arm-forearm or the arm-ankle was within the ± 10% range in 63% and 29% of measurements, and within the ± 20% range in 85% and 67% of measurements, respectively. The diastolic blood pressure difference between the arm-forearm or the arm-ankle was within the ± 10% range in 42% and 44% and within the ± 20% range in 67% and 74% of measurements, respectively. In patients in whom the initial three NIBP measurements were within the ± 20% range between the forearm and arm, 86% of the subsequent measurements were also within that limit. Forearm and ankle NIBP measurements are unreliable and inconsistent with NIBP measured in the arm of anesthetized children. These alternative BP measurement sites are not reliable in accuracy (comparison with reference "gold" standard) and precision (reproducibility). Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Simulated self-motion in a visual gravity field: sensitivity to vertical and horizontal heading in the human brain.

    Science.gov (United States)

    Indovina, Iole; Maffei, Vincenzo; Pauwels, Karl; Macaluso, Emiliano; Orban, Guy A; Lacquaniti, Francesco

    2013-05-01

    Multiple visual signals are relevant to perception of heading direction. While the role of optic flow and depth cues has been studied extensively, little is known about the visual effects of gravity on heading perception. We used fMRI to investigate the contribution of gravity-related visual cues on the processing of vertical versus horizontal apparent self-motion. Participants experienced virtual roller-coaster rides in different scenarios, at constant speed or 1g-acceleration/deceleration. Imaging results showed that vertical self-motion coherent with gravity engaged the posterior insula and other brain regions that have been previously associated with vertical object motion under gravity. This selective pattern of activation was also found in a second experiment that included rectilinear motion in tunnels, whose direction was cued by the preceding open-air curves only. We argue that the posterior insula might perform high-order computations on visual motion patterns, combining different sensory cues and prior information about the effects of gravity. Medial-temporal regions including para-hippocampus and hippocampus were more activated by horizontal motion, preferably at constant speed, consistent with a role in inertial navigation. Overall, the results suggest partially distinct neural representations of the cardinal axes of self-motion (horizontal and vertical). Copyright © 2013 Elsevier Inc. All rights reserved.

  16. The effect of radial head implant shape on radiocapitellar kinematics during in vitro forearm rotation.

    Science.gov (United States)

    Shannon, Hannah L; Deluce, Simon R; Giles, Joshua W; Johnson, James A; King, Graham J W

    2015-02-01

    A number of radial head implants are in clinical use for the management of radial head fractures and their sequelae. However, the optimal shape of a radial head implant to ensure proper tracking relative to the capitellum has not been established. This in vitro biomechanical study compared radiocapitellar joint kinematics for 3 radial head implant designs as well as the native head. Eight cadaveric upper extremities were tested using a forearm rotation simulator with the elbow at 90° of flexion. Motion of the radius relative to the capitellum was optically tracked. A stem was navigated into a predetermined location and cemented in place. Three unipolar implant shapes were tested: axisymmetric, reverse-engineered patient-specific, and population-based quasi-anatomic. The patient-specific and quasi-anatomic implants were derived from measurements performed on computed tomography models. Medial-lateral and anterior-posterior translation of the radial head with respect to the capitellum varied with forearm rotation and radial head condition. A significant difference in medial-lateral (P = .03) and anterior-posterior (P = .03) translation was found between the native radial head and the 3 implants. No differences were observed among the radial head conditions except for a difference in medial-lateral translation between the axisymmetric and patient-specific implants (P = .04). Radiocapitellar kinematics of the tested radial head implants were similar in all but one comparison, and all had different kinematics from the native radial head. Patient-specific radial head implants did not prove advantageous relative to conventional implant designs. The shape of the fixed stem unipolar radial head implants had little influence on radiocapitellar kinematics when optimally positioned in this testing model. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  17. Forearm muscle oxygenation during sustained isometric contractions in rock climbers

    Directory of Open Access Journals (Sweden)

    Jan Kodejška

    2016-02-01

    Full Text Available Background. Bouldering and lead climbing are divergent disciplines of the sport of rock climbing. Bouldering moves are short and powerful, whilst sport climbing is longer and require a greater degree of endurance. Aim. The aim of this study was to compare forearm muscle oxygenation during sustained isometric contraction between lead climbers (LC and boulderers (BO. Methods. Eight BO and twelve LC completed maximal finger flexor strength test and sustained contractions to exhaustion at 60% of maximum voluntary contraction (MVC. Differences between BO and LC in maximal strength, time to exhaustion, force time integral (FTI, and tissue oxygenation (SmO2 were assessed by t-test for independent samples. Results. LC showed significantly lower level of average tissue oxygenation (BO 38.9% SmO2, s = 7.4; LC 28.7% SmO2, s = 7.1 and maximal tissue deoxygenation (BO 25.6% SmO2, s = 8.2; LC 13.5% SmO2, s = 8.5. LC demonstrated significantly lower finger flexor strength (519 N, s = 72 than BO (621 N, s = 142. LC sustained a longer time of contraction (not significantly (BO 52.2 s, s = 11.5; LC 60.6 s, s = 13 and achieved a similar value of FTI (BO 17421 Ns, s = 4291; LO 17476 Ns, s = 5036 in the endurance test. Conclusions. The results showed lower deoxygenation during sustained contraction in BO than LC despite similar FTI, indicating different local metabolic pathways in both groups.

  18. Processing of targets in smooth or apparent motion along the vertical in the human brain: an fMRI study.

    Science.gov (United States)

    Maffei, Vincenzo; Macaluso, Emiliano; Indovina, Iole; Orban, Guy; Lacquaniti, Francesco

    2010-01-01

    Neural substrates for processing constant speed visual motion have been extensively studied. Less is known about the brain activity patterns when the target speed changes continuously, for instance under the influence of gravity. Using functional MRI (fMRI), here we compared brain responses to accelerating/decelerating targets with the responses to constant speed targets. The target could move along the vertical under gravity (1g), under reversed gravity (-1g), or at constant speed (0g). In the first experiment, subjects observed targets moving in smooth motion and responded to a GO signal delivered at a random time after target arrival. As expected, we found that the timing of the motor responses did not depend significantly on the specific motion law. Therefore brain activity in the contrast between different motion laws was not related to motor timing responses. Average BOLD signals were significantly greater for 1g targets than either 0g or -1g targets in a distributed network including bilateral insulae, left lingual gyrus, and brain stem. Moreover, in these regions, the mean activity decreased monotonically from 1g to 0g and to -1g. In the second experiment, subjects intercepted 1g, 0g, and -1g targets either in smooth motion (RM) or in long-range apparent motion (LAM). We found that the sites in the right insula and left lingual gyrus, which were selectively engaged by 1g targets in the first experiment, were also significantly more active during 1g trials than during -1g trials both in RM and LAM. The activity in 0g trials was again intermediate between that in 1g trials and that in -1g trials. Therefore in these regions the global activity modulation with the law of vertical motion appears to hold for both RM and LAM. Instead, a region in the inferior parietal lobule showed a preference for visual gravitational motion only in LAM but not RM.

  19. Custom-designed motion-based games for older adults: a review of literature in human-computer interaction

    OpenAIRE

    Gerling, Kathrin; Mandryk, Regan

    2014-01-01

    Many older adults, particularly persons living in senior residences and care homes, lead sedentary lifestyles, which reduces their life expectancy. Motion-based video games encourage physical activity and might be an opportunity for these adults to remain active and engaged; however, research efforts in the field have frequently focused on younger audiences and little is known about the requirements and benefits of motion-based games for elderly players. In this paper, we present an overview ...

  20. Motion Learning Based on Bayesian Program Learning

    Directory of Open Access Journals (Sweden)

    Cheng Meng-Zhen

    2017-01-01

    Full Text Available The concept of virtual human has been highly anticipated since the 1980s. By using computer technology, Human motion simulation could generate authentic visual effect, which could cheat human eyes visually. Bayesian Program Learning train one or few motion data, generate new motion data by decomposing and combining. And the generated motion will be more realistic and natural than the traditional one.In this paper, Motion learning based on Bayesian program learning allows us to quickly generate new motion data, reduce workload, improve work efficiency, reduce the cost of motion capture, and improve the reusability of data.

  1. Ten days of repeated local forearm heating does not affect cutaneous vascular function.

    Science.gov (United States)

    Francisco, Michael A; Brunt, Vienna E; Jensen, Krista Nicole; Lorenzo, Santiago; Minson, Christopher T

    2017-08-01

    The aim of the present study was to determine whether 10 days of repeated local heating could induce peripheral adaptations in the cutaneous vasculature and to investigate potential mechanisms of adaptation. We also assessed maximal forearm blood flow to determine whether repeated local heating affects maximal dilator capacity. Before and after 10 days of heat training consisting of 1-h exposures of the forearm to 42°C water or 32°C water (control) in the contralateral arm (randomized and counterbalanced), we assessed hyperemia to rapid local heating of the skin ( n = 14 recreationally active young subjects). In addition, sequential doses of acetylcholine (ACh, 1 and 10 mM) were infused in a subset of subjects ( n = 7) via microdialysis to study potential nonthermal microvascular adaptations following 10 days of repeated forearm heat training. Skin blood flow was assessed using laser-Doppler flowmetry, and cutaneous vascular conductance (CVC) was calculated as laser-Doppler red blood cell flux divided by mean arterial pressure. Maximal cutaneous vasodilation was achieved by heating the arm in a water-spray device for 45 min and assessed using venous occlusion plethysmography. Forearm vascular conductance (FVC) was calculated as forearm blood flow divided by mean arterial pressure. Repeated forearm heating did not increase plateau percent maximal CVC (CVC max ) responses to local heating (89 ± 3 vs. 89 ± 2% CVC max , P = 0.19), 1 mM ACh (43 ± 9 vs. 53 ± 7% CVC max , P = 0.76), or 10 mM ACh (61 ± 9 vs. 85 ± 7% CVC max , P = 0.37, by 2-way repeated-measures ANOVA). There was a main effect of time at 10 mM ACh ( P = 0.03). Maximal FVC remained unchanged (0.12 ± 0.02 vs. 0.14 ± 0.02 FVC, P = 0.30). No differences were observed in the control arm. Ten days of repeated forearm heating in recreationally active young adults did not improve the microvascular responsiveness to ACh or local heating. NEW & NOTEWORTHY We show for the first time that 10 days of repeated

  2. Research on Three-dimensional Motion History Image Model and Extreme Learning Machine for Human Body Movement Trajectory Recognition

    Directory of Open Access Journals (Sweden)

    Zheng Chang

    2015-01-01

    Full Text Available Based on the traditional machine vision recognition technology and traditional artificial neural networks about body movement trajectory, this paper finds out the shortcomings of the traditional recognition technology. By combining the invariant moments of the three-dimensional motion history image (computed as the eigenvector of body movements and the extreme learning machine (constructed as the classification artificial neural network of body movements, the paper applies the method to the machine vision of the body movement trajectory. In detail, the paper gives a detailed introduction about the algorithm and realization scheme of the body movement trajectory recognition based on the three-dimensional motion history image and the extreme learning machine. Finally, by comparing with the results of the recognition experiments, it attempts to verify that the method of body movement trajectory recognition technology based on the three-dimensional motion history image and extreme learning machine has a more accurate recognition rate and better robustness.

  3. Hand interception of occluded motion in humans: a test of model-based vs. on-line control.

    Science.gov (United States)

    La Scaleia, Barbara; Zago, Myrka; Lacquaniti, Francesco

    2015-09-01

    Two control schemes have been hypothesized for the manual interception of fast visual targets. In the model-free on-line control, extrapolation of target motion is based on continuous visual information, without resorting to physical models. In the model-based control, instead, a prior model of target motion predicts the future spatiotemporal trajectory. To distinguish between the two hypotheses in the case of projectile motion, we asked participants to hit a ball that rolled down an incline at 0.2 g and then fell in air at 1 g along a parabola. By varying starting position, ball velocity and trajectory differed between trials. Motion on the incline was always visible, whereas parabolic motion was either visible or occluded. We found that participants were equally successful at hitting the falling ball in both visible and occluded conditions. Moreover, in different trials the intersection points were distributed along the parabolic trajectories of the ball, indicating that subjects were able to extrapolate an extended segment of the target trajectory. Remarkably, this trend was observed even at the very first repetition of movements. These results are consistent with the hypothesis of model-based control, but not with on-line control. Indeed, ball path and speed during the occlusion could not be extrapolated solely from the kinematic information obtained during the preceding visible phase. The only way to extrapolate ball motion correctly during the occlusion was to assume that the ball would fall under gravity and air drag when hidden from view. Such an assumption had to be derived from prior experience. Copyright © 2015 the American Physiological Society.

  4. List-Mode PET Motion Correction Using Markerless Head Tracking: Proof-of-Concept With Scans of Human Subject

    DEFF Research Database (Denmark)

    Olesen, Oline Vinter; Sullivan, Jenna M.; Mulnix, Tim

    2013-01-01

    A custom designed markerless tracking system was demonstrated to be applicable for positron emission tomography (PET) brain imaging. Precise head motion registration is crucial for accurate motion correction (MC) in PET imaging. State-of-the-art tracking systems applied with PET brain imaging rely...... on markers attached to the patient's head. The marker attachment is the main weakness of these systems. A healthy volunteer participating in a cigarette smoking study to image dopamine release was scanned twice for 2 h with $^{11}{\\rm C}$-racolopride on the high resolution research tomograph (HRRT) PET...... in contrast recovery of small structures....

  5. Peroneal perforator-based peroneus longus tendon and sural neurofasciocutaneous composite flap transfer for a large soft-tissue defect of the forearm: A case report.

    Science.gov (United States)

    Hayashida, Kenji; Saijo, Hiroto; Fujioka, Masaki

    2018-01-01

    We describe the use of a composite flap composed of a sural neurofasciocutaneous flap and a vascularized peroneus longus tendon for the reconstruction of severe composite forearm tissue defects in a patient. A 43-year-old man had his left arm caught in a conveyor belt resulting in a large soft-tissue defect of 18 × 11 cm over the dorsum forearm. The extensor carpi radialis, superficial radial nerve, and radial artery were severely damaged. A free neurofasciocutaneous composite flap measuring 16 × 11 cm was outlined on the patient's left lower leg to allow simultaneous skin, tendon, nerve, and artery reconstruction. The flap, which included the peroneus longus tendon, was elevated on the subfascial plane. After the flap was transferred to the recipient site, the peroneal artery was anastomosed to the radial artery in a flow-through manner. The vascularized tendon graft with 15 cm in length was used to reconstruct the extensor carpi radialis longus tendon defect using an interlacing suture technique. As the skin paddle of the sural neurofasciocutaneous flap and the vascularized peroneus longus tendon graft were linked by the perforator and minimal fascial tissue, the skin paddle was able to rotate and slide with comparative ease. The flap survived completely without any complications. The length of follow-up was 12 months and was uneventful. Range of motion of his left wrist joint was slightly limited to 75 degrees. This novel composite flap may be useful for reconstructing long tendon defects associated with extensive forearm soft tissue defects. © 2016 Wiley Periodicals, Inc.

  6. High incidence of the median artery of the forearm in a sample of recent southern African cadavers.

    Science.gov (United States)

    Henneberg, M; George, B J

    1992-01-01

    Observations of the presence of the median artery, providing substantial blood supply to the hand, were conducted on 96 dissected forearms of 15 adult African females and 49 adult males. The artery has a much higher incidence (27.1%) than previously reported by any author. There is no significant difference in its occurrence between sexes, nor between right and left limbs. The artery seems to occur more often bilaterally than unilaterally. The presence of the artery is not related to age. From a theoretical standpoint it is difficult to accept that a structure present in more than 1 in 4 of individuals should be considered an 'anomaly' or a 'variant'. A different approach to description of normal human anatomy is therefore necessary--that of presenting alternative anatomical patterns of equal standing rather than a single 'normal' pattern. Images Fig. 1 Fig. 2 Fig. 3 PMID:1452474

  7. Optimization-based human motion prediction using an inverse-inverse dynamics technique implemented in the AnyBody Modeling System

    DEFF Research Database (Denmark)

    Farahani, Saeed Davoudabadi; Andersen, Michael Skipper; de Zee, Mark

    2012-01-01

    derived from the detailed musculoskeletal analysis. The technique is demonstrated on a human model pedaling a bicycle. We use a physiology-based cost function expressing the mean square of all muscle activities over the cycle to predict a realistic motion pattern. Posture and motion prediction...... on a physics model including dynamic effects and a high level of anatomical realism. First, a musculoskeletal model comprising several hundred muscles is built in AMS. The movement is then parameterized by means of time functions controlling selected degrees of freedom of the model. Subsequently......, the parameters of these functions are optimized to produce an optimum posture or movement according to a user-defined cost function and constraints. The cost function and the constraints are typically express performance, comfort, injury risk, fatigue, muscle load, joint forces and other physiological properties...

  8. Shooting performance is related to forearm temperature and hand tremor size.

    Science.gov (United States)

    Lakie, M; Villagra, F; Bowman, I; Wilby, R

    1995-08-01

    The changes in postural tremor of the hand and the subsequent effect on shooting performance produced by moderate cooling and heating of the forearm were studied in six subjects. Cooling produced a large decrease in tremor size of the ipsilateral hand, whereas warming the limb produced an increase in tremor size. Cooling or warming the forearm did not change the peak frequency of tremor significantly, which was quite stable for each subject. The improvement in shooting performance after cooling the forearm, as measured by grouping pattern of the shots, reached statistical significance and warming caused a significant worsening. This measure of performance was shown to correlate (r = 0.776) inversely with tremor size. The causes and implications of these changes are discussed. It is suggested that local cooling may be useful for people who wish temporarily to reduce tremor in order to improve dexterity for shooting and for other purposes.

  9. Anatomic Variation of the Median Nerve Associated with an Anomalous Muscle of the Forearm.

    Science.gov (United States)

    Atoni, Atoni Dogood; Oyinbo, Charles Aidemise

    2017-03-01

    Documented anatomical variations are important not only for the study of the subject of anatomy, but also in clinical situation. This knowledge would aid surgeons in planning a preoperative strategy for surgical procedures and reconstructive surgery. The right forearm of a 35-year-old embalmed male cadaver present a splitting of the median nerve in the proximal 1/3 of the forearm to form medial and lateral divisions that accommodate an anomalous muscle. The split median nerve reunites at the distal 1/3 and continues as a single nerve. The anomalous muscle arises by muscle fibers from flexor digitorum superficialis and inserted by tendon into flexor digitorum profundus. There was no such variation in the left forearm. The knowledge of such anatomical variations is important to clinicians and surgeons in interpreting atypical clinical presentations and avoiding unusual injury during surgery.

  10. Anatomic Variation of the Median Nerve Associated with an Anomalous Muscle of the Forearm

    Directory of Open Access Journals (Sweden)

    Atoni Atoni Dogood

    2017-03-01

    Full Text Available Documented anatomical variations are important not only for the study of the subject of anatomy, but also in clinical situation. This knowledge would aid surgeons in planning a preoperative strategy for surgical procedures and reconstructive surgery. The right forearm of a 35-year-old embalmed male cadaver present a splitting of the median nerve in the proximal 1/3 of the forearm to form medial and lateral divisions that accommodate an anomalous muscle. The split median nerve reunites at the distal 1/3 and continues as a single nerve. The anomalous muscle arises by muscle fibers from flexor digitorum superficialis and inserted by tendon into flexor digitorum profundus. There was no such variation in the left forearm. The knowledge of such anatomical variations is important to clinicians and surgeons in interpreting atypical clinical presentations and avoiding unusual injury during surgery.

  11. Free myocutaneous flap transfer to treat congenital Volkmann's contracture of the forearm.

    Science.gov (United States)

    Rubin, G; Palti, R; Gurevitz, S; Yaffe, B

    2015-07-01

    The purpose of this study is to report our experience with free functional muscle transfer procedures for the late sequelae of the rare condition of congenital Volkmann's ischaemic contracture of the forearm. Four children, with an average age of 9.5 years (range 1.5-17), were treated and were followed for a mean of 6 years (range 1-14). Two patients had dorsal forearm contractures, and two had both flexor and extensor forearm contractures. We carried out free functional muscle transfers to replace the flexor or extensor muscles. The functional result was assessed according to the classification system of Hovius and Ultee. All patients had wrist contractures and skeletal involvement with limb length discrepancy that influenced the outcome. All five transferred muscles survived and improved the function of the hand in three of the four patients. LEVEL OF EVIDENCE 4. © The Author(s) 2014.

  12. Complications after percutaneous placement of totally implantable venous access ports in the forearm

    International Nuclear Information System (INIS)

    Goltz, J.P.; Petritsch, B.; Thurner, A.; Hahn, D.; Kickuth, R.

    2012-01-01

    This article focuses on radiological imaging of complications after interventional percutaneous insertion of totally implantable venous access ports (TIVAPs) which were placed in the forearm. Thus far most reviews have dealt with pectorally-placed TIVAPs. Compared with the pectoral approach, implantation in the forearm has been associated with certain complications owing to a longer route of the port catheter within a smaller vein, and owing to the route across the elbow joint, resulting in higher rates of catheter-associated thrombosis and possible mechanical complications. The purpose of this review is to describe the complications after implantation of TIVAPs in the forearm, and to make radiologists familiar with the key findings of the complications during radiological imaging, including colour-coded and compression Duplex ultrasound, computed tomography, and digital subtraction venography.

  13. Level of Agreement Between Forearm and Upper Arm Blood Pressure Measurements in Patients With Large Arm Circumference.

    Science.gov (United States)

    Watson, Sheri; Aguas, Marita; Colegrove, Pat; Foisy, Nancy; Jondahl, Bonnie; Anastas, Zoe

    2017-02-01

    The purpose of the study was to determine if forearm blood pressures (BPs) measured in three different locations agree with the recommended upper arm location for noninvasive BP measurement. A method-comparison design was used. In a convenience sample of postanesthesia care unit patients with large upper arm circumference, BP's were obtained in three different forearm locations (lower forearm, middle forearm, and upper forearm) and compared to upper arm BP using an automated BP measuring device. The level of agreement (bias ± precision) between each forearm location and the upper arm BP was calculated using standard formulas. Acceptable levels of agreement based on expert opinion were set a priori at bias and precision values of less than ±5 mm Hg (bias) and ±8 mm Hg (precision). Forty-eight postanesthesia patients participated in the study. Bias and precision values were found to exceed the acceptable level of agreement for all but one of the systolic and diastolic BP comparisons in the three forearm BP locations. Fifty-six percent of all patients studied had one or more BP difference of at least 10 mm Hg in each of the three forearm locations, with 10% having one or more differences of at least 20 mm Hg. The differences in forearm BP measurements observed in this study indicate that the clinical practice of using a forearm BP with a regular-sized BP cuff in place of a larger sized BP cuff placed on the upper arm in postanesthesia care unit patients with large arm circumferences is inappropriate. The BPs obtained at the forearm location are not equivalent to the BPs obtained at the upper arm location. Copyright © 2015 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.

  14. Screw elastic intramedullary nail for the management of adult forearm fractures

    Directory of Open Access Journals (Sweden)

    Wasudeo Gadegone

    2012-01-01

    Full Text Available Background: The failure of the conventional nailing of both forearm bones or isolated fractures of radius and ulna pose a potential problem of nail migration and rotational instability, despite the best reduction. The purpose of this paper is to evaluate the results of screw elastic intramedullary nail for the treatment of adult diaphyseal fractures of both forearm bones, which effectively addresses the problems associated with the conventional nailing systems for the forearm fractures. Materials and Methods: Seventy-six adults with forearm fractures (radius and ulna or isolated fracture of the single bone were retrospectively evaluated. Fifty males and 26 females with the mean age of 38 years (range, 18-70 years underwent closed reduction and screw intramedullary nail fixation. Ten patients required limited open reduction. The fractures were classified according to the AO/OTA system. The average followup was 12 months (range, 6 to 18 months. Results: The mean surgical time was 45 minutes (35 to 65 minutes. The meantime to union was 14 weeks (10-21 weeks. The results were graded as excellent in 50, good in 18 patients, and acceptable in eight patients, using the criteria of Grace and Eversman. We had superficial infection in three cases, one case of delayed infection, painful bursa in two cases, delayed union in two cases, malunion with dislocation of the DRUJ in two cases, injury to the extensor tendon of the thumb in one case, and one case of incomplete radioulnar synostosis. Conclusion: Closed reduction and internal fixation of forearm fractures by screw intramedullary nails reestablishes the near normal relationship of the fractured fragments. Screw intramedullary nail effectively controls both rotatory forces and the migration of the nail. It produces excellent clinical results in isolated fractures of either bones, as well as both bones of the forearm in adults.

  15. The influence of cooling forearm/hand and gender on estimation of handgrip strength.

    Science.gov (United States)

    Cheng, Chih-Chan; Shih, Yuh-Chuan; Tsai, Yue-Jin; Chi, Chia-Fen

    2014-01-01

    Handgrip strength is essential in manual operations and activities of daily life, but the influence of forearm/hand skin temperature on estimation of handgrip strength is not well documented. Therefore, the present study intended to investigate the effect of local cooling of the forearm/hand on estimation of handgrip strength at various target force levels (TFLs, in percentage of MVC) for both genders. A cold pressor test was used to lower and maintain the hand skin temperature at 14°C for comparison with the uncooled condition. A total of 10 male and 10 female participants were recruited. The results indicated that females had greater absolute estimation deviations. In addition, both genders had greater absolute deviations in the middle range of TFLs. Cooling caused an underestimation of grip strength. Furthermore, a power function is recommended for establishing the relationship between actual and estimated handgrip force. Statement of relevance: Manipulation with grip strength is essential in daily life and the workplace, so it is important to understand the influence of lowering the forearm/hand skin temperature on grip-strength estimation. Females and the middle range of TFL had greater deviations. Cooling the forearm/hand tended to cause underestimation, and a power function is recommended for establishing the relationship between actual and estimated handgrip force. Practitioner Summary: It is important to understand the effect of lowering the forearm/hand skin temperature on grip-strength estimation. A cold pressor was used to cool the hand. The cooling caused underestimation, and a power function is recommended for establishing the relationship between actual and estimated handgrip force. Manipulation with grip strength is essential in daily life and the workplace, so it is important to understand the influence of lowering the forearm/hand skin temperature on grip-strength estimation. Females and the middle range of TFL had greater deviations. Cooling the

  16. Extensive forearm deep venous thrombosis following a severe infliximab infusion reaction.

    Science.gov (United States)

    Ryan, Barbara M; Romberg, Marielle; Wolters, Frank; Stockbrugger, Reinhold W

    2004-09-01

    Here we describe a patient with Crohn's disease who developed a severe infliximab infusion reaction (IIR), complicated 1 day later by severe swelling of the forearm and hand ipsilateral to the site of infliximab infusion. This proved to be extensive forearm deep venous thrombosis. The site of thrombosis and the chronological relationship with the IIR implicates a hypersensitivity to infliximab in the causation of the venous thrombosis in this case. With an increasing trend towards re-treating patients with known IIRs, clinicians should be aware of this potentially serious and previously unreported complication.

  17. Water filtration of the forearm in short- and long-term diabetes mellitus

    DEFF Research Database (Denmark)

    Poulsen, H L; Nielsen, S L

    1976-01-01

    of the forearm. Increased water filtration in connective tissue in long-term diabetics is in accordance with earlier findings of a lowered subcutaneous interstitial fluid albumin concentration in long-term diabetics, this being explained by an increase in net water outflux from the microcirculation.......Blood flow and capillary filtration coefficient (CFC) were measured by strain-gauge plethysmography on the upper and lower third of the forearm in 9 normal subjects and 29 well regulated patients with diabetes mellitus of varying duration (less than 10 years, 10 to 20 years, and more than 20 years...

  18. Resistance exercise with different volumes: blood pressure response and forearm blood flow in the hypertensive elderly

    Directory of Open Access Journals (Sweden)

    Brito AF

    2014-12-01

    Full Text Available Aline de Freitas Brito,1 Caio Victor Coutinho de Oliveira,2 Maria do Socorro Brasileiro-Santos,1 Amilton da Cruz Santos1 1Physical Education Department, 2Research Laboratory for Physical Training Applied to Performance and Health, Federal University of Paraíba, João Pessoa, Brazil Background: The purpose of this study was to evaluate the effect of two sessions of resistance exercise with different volumes on post-exercise hypotension, forearm blood flow, and forearm vascular resistance in hypertensive elderly subjects.Methods: The study was conducted with ten hypertensive elderly (65±3 years, 28.7±3 kg/m2 subjected to three experimental sessions, ie, a control session, exercise with a set (S1, and exercise with three sets (S3. For each session, the subjects were evaluated before and after intervention. In the pre-intervention period, blood pressure, forearm blood flow, and forearm vascular resistance were measured after 10 minutes of rest in the supine position. Thereafter, the subjects were taken to the gym to perform their exercise sessions or remained at rest during the same time period. Both S1 and S3 comprised a set of ten repetitions of ten exercises, with an interval of 90 seconds between exercises. Subsequently, the measurements were again performed at 10, 30, 50, 70, and 90 minutes of recovery (post-intervention in the supine position.Results: Post-exercise hypotension was greater in S3 than in S1 (systolic blood pressure, −26.5±4.2 mmHg versus −17.9±4.7 mmHg; diastolic blood pressure, −13.8±4.9 mmHg versus −7.7±5 mmHg, P<0.05. Similarly, forearm blood flow and forearm vascular resistance changed significantly in both sessions with an increase and decrease, respectively, that was more evident in S3 than in S1 (P<0.05.Conclusion: Resistance exercises with higher volume were more effective in causing post-exercise hypotension, being accompanied by an increase in forearm blood flow and a reduction of forearm vascular

  19. Quantitative trait loci on chromosomes 2p, 4p, and 13q influence bone mineral density of the forearm and hip in Mexican Americans.

    Science.gov (United States)

    Kammerer, Candace M; Schneider, Jennifer L; Cole, Shelley A; Hixson, James E; Samollow, Paul B; O'Connell, Jeffrey R; Perez, Reina; Dyer, Thomas D; Almasy, Laura; Blangero, John; Bauer, Richard L; Mitchell, Braxton D

    2003-12-01

    We performed a genome scan using BMD data of the forearm and hip on 664 individuals in 29 Mexican-American families. We obtained evidence for QTL on chromosome 4p, affecting forearm BMD overall, and on chromosomes 2p and 13q, affecting hip BMD in men. The San Antonio Family Osteoporosis Study (SAFOS) was designed to identify genes and environmental factors that influence bone mineral density (BMD) using data from large Mexican-American families. We performed a genome-wide linkage analysis using 416 highly polymorphic microsatellite markers spaced approximately 9.5 cM apart to locate and identify quantitative trait loci (QTL) that affect BMD of the forearm and hip. Multipoint variance components linkage analyses were done using data on all 664 subjects, as well as two subgroups of 259 men and 261 premenopausal women, from 29 families for which genotypic and phenotypic data were available. We obtained significant evidence for a QTL affecting forearm (radius midpoint) BMD in men and women combined on chromosome 4p near D4S2639 (maximum LOD = 4.33, genomic p = 0.006) and suggestive evidence for a QTL on chromosome 12q near locus D12S2070 (maximum conditional LOD = 2.35). We found suggestive evidence for a QTL influencing trochanter BMD on chromosome 6 (maximum LOD = 2.27), but no evidence for QTL affecting the femoral neck in men and women combined. In men, we obtained evidence for QTL affecting neck and trochanter BMD on chromosomes 2p near D2S1780 (maximum LOD = 3.98, genomic p = 0.013) and 13q near D13S788 (maximum LOD = 3.46, genomic p = 0.039), respectively. We found no evidence for QTL affecting forearm or hip BMD in premenopausal women. These results provide strong evidence that a QTL on chromosome 4p affects radius BMD in Mexican-American men and women, as well as evidence that QTL on chromosomes 2p and 13q affect hip BMD in men. Our results are consistent with some reports in humans and mice. J Bone Miner Res 2003;18:2245-2252

  20. Flexible and Compressible PEDOT:PSS@Melamine Conductive Sponge Prepared via One-Step Dip Coating as Piezoresistive Pressure Sensor for Human Motion Detection.

    Science.gov (United States)

    Ding, Yichun; Yang, Jack; Tolle, Charles R; Zhu, Zhengtao

    2018-05-09

    Flexible and wearable pressure sensor may offer convenient, timely, and portable solutions to human motion detection, yet it is a challenge to develop cost-effective materials for pressure sensor with high compressibility and sensitivity. Herein, a cost-efficient and scalable approach is reported to prepare a highly flexible and compressible conductive sponge for piezoresistive pressure sensor. The conductive sponge, poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS)@melamine sponge (MS), is prepared by one-step dip coating the commercial melamine sponge (MS) in an aqueous dispersion of poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS). Due to the interconnected porous structure of MS, the conductive PEDOT:PSS@MS has a high compressibility and a stable piezoresistive response at the compressive strain up to 80%, as well as good reproducibility over 1000 cycles. Thereafter, versatile pressure sensors fabricated using the conductive PEDOT:PSS@MS sponges are attached to the different parts of human body; the capabilities of these devices to detect a variety of human motions including speaking, finger bending, elbow bending, and walking are evaluated. Furthermore, prototype tactile sensory array based on these pressure sensors is demonstrated.

  1. Forearm vascular response to nitric oxide and calcitonin gene-related peptide: comparison between migraine patients and control subjects.

    NARCIS (Netherlands)

    Hoon, J.N. de; Smits, P.; Troost, J.; Struijker-Boudier, H.A.; Bortel, L.M. van

    2006-01-01

    The forearm vascular response to nitric oxide (NO) and calcitonin gene-related peptide (CGRP) was investigated in 10 migraine patients and 10 matched control subjects. Changes in forearm blood flow (FBF) during intrabrachial infusion of: (i) serotonin (releasing endogenous NO), (ii) sodium

  2. Multifunctional devices based on SnO2@rGO-coated fibers for human motion monitoring, ethanol detection, and photo response

    Science.gov (United States)

    Mi, Qing; Wang, Qi; Zang, Siyao; Chai, Zhaoer; Zhang, Jinnan; Ren, Xiaomin

    2018-05-01

    In this study, we developed a multifunctional device based on SnO2@rGO-coated fibers utilizing plasma treatment, dip coating, and microwave irradiation in sequence, and finally realized highly sensitive human motion monitoring, relatively good ethanol detection, and an obvious photo response. Moreover, the high level of comfort and compactness derived from highly elastic and comfortable fabrics contributes to the long-term availability and test accuracy. As an attempt at multifunctional integration of smart clothing, this work provides an attractive and relatively practical research direction.

  3. [A new human machine interface in neurosurgery: The Leap Motion(®). Technical note regarding a new touchless interface].

    Science.gov (United States)

    Di Tommaso, L; Aubry, S; Godard, J; Katranji, H; Pauchot, J

    2016-06-01

    Currently, cross-sectional imaging viewing is used in routine practice whereas the surgical procedure requires physical contact with an interface (mouse or touch-sensitive screen). This type of contact results in a risk of lack of aseptic control and causes loss of time. The recent appearance of devices such as the Leap Motion(®) (Leap Motion society, San Francisco, USA) a sensor which enables to interact with the computer without any physical contact is of major interest in the field of surgery. However, its configuration and ergonomics produce key challenges in order to adapt to the practitioner's requirements, the imaging software as well as the surgical environment. This article aims to suggest an easy configuration of the Leap Motion(®) in neurosurgery on a PC for an optimized utilization with Carestream(®) Vue PACS v11.3.4 (Carestream Health, Inc., Rochester, USA) using a plug-in (to download at: https://drive.google.com/?usp=chrome_app#folders/0B_F4eBeBQc3ybElEeEhqME5DQkU) and a video tutorial (https://www.youtube.com/watch?v=yVPTgxg-SIk). Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  4. Toward the restoration of hand use to a paralyzed monkey: brain-controlled functional electrical stimulation of forearm muscles.

    Directory of Open Access Journals (Sweden)

    Eric A Pohlmeyer

    2009-06-01

    Full Text Available Loss of hand use is considered by many spinal cord injury survivors to be the most devastating consequence of their injury. Functional electrical stimulation (FES of forearm and hand muscles has been used to provide basic, voluntary hand grasp to hundreds of human patients. Current approaches typically grade pre-programmed patterns of muscle activation using simple control signals, such as those derived from residual movement or muscle activity. However, the use of such fixed stimulation patterns limits hand function to the few tasks programmed into the controller. In contrast, we are developing a system that uses neural signals recorded from a multi-electrode array implanted in the motor cortex; this system has the potential to provide independent control of multiple muscles over a broad range of functional tasks. Two monkeys were able to use this cortically controlled FES system to control the contraction of four forearm muscles despite temporary limb paralysis. The amount of wrist force the monkeys were able to produce in a one-dimensional force tracking task was significantly increased. Furthermore, the monkeys were able to control the magnitude and time course of the force with sufficient accuracy to track visually displayed force targets at speeds reduced by only one-third to one-half of normal. Although these results were achieved by controlling only four muscles, there is no fundamental reason why the same methods could not be scaled up to control a larger number of muscles. We believe these results provide an important proof of concept that brain-controlled FES prostheses could ultimately be of great benefit to paralyzed patients with injuries in the mid-cervical spinal cord.

  5. Orientation of axes in the elbow and forearm for biomechanical modelling

    NARCIS (Netherlands)

    Veeger, H. E J; Yu, B.

    1996-01-01

    To determine the three-dimensional positions and orientations of axes of rotation for elbow flexion and forearm prosupination, the flexion-extension and prosupination movements were measured for five arms. Four right and one arm were taken from four fresh cadavers. Movement was measured with a

  6. Changes in forearm muscle temperature alter renal vascular responses to isometric handgrip.

    Science.gov (United States)

    Kuipers, Nathan T; Sauder, Charity L; Kearney, Matthew L; Ray, Chester A

    2007-12-01

    The purpose of the present study was to examine the effect of heating and cooling the forearm muscles on renal vascular responses to ischemic isometric handgrip (IHG). It was hypothesized that heating and cooling the forearm would augment and attenuate, respectively, renal vascular responses to IHG. Renal vascular responses to IHG were studied during forearm heating at 39 degrees C (n = 15, 26 +/- 1 yr) and cooling at 26 degrees C (n = 12, 26 +/- 1 yr). For a control trial, subjects performed the experimental protocol while the forearm was normothermic (approximately 34 degrees C). Muscle temperature (measured by intramuscular probe) was controlled by changing the temperature of water cycling through a water-perfused sleeve. The experimental protocol was as follows: 3 min at baseline, 1 min of ischemia, ischemic IHG to fatigue, and 2 min of postexercise muscle ischemia. At rest, renal artery blood velocity (RBV; Doppler ultrasound) and renal vascular conductance (RVC = RBV/mean arterial blood pressure) were not different between normothermia and the two thermal conditions. During ischemic IHG, there were greater decreases in RBV and RVC in the heating trial. However, RBV and RVC were similar during postexercise muscle ischemia during heating and normothermia. RVC decreased less during cooling than in normothermia while the subjects performed the ischemic IHG protocol. During postexercise muscle ischemia, RVC was greater during cooling than in normothermia. These results indicate that heating augments mechanoreceptor-mediated renal vasoconstriction whereas cooling blunts metaboreceptor-mediated renal vasoconstriction.

  7. Treatment Results Of Diaphyseal Forearm Fractures With Dynamique Compression Plate A Retrospective study of 156 Cases.

    Directory of Open Access Journals (Sweden)

    Hassan BOUSSAKRI

    2015-12-01

    Full Text Available This retrospective study addresses a series of 156 cases of forearm fractures. These 156 cases were managed in the trauma-orthopedic department (B4 of Fez University Hospital, Morocco, from May 2008 till January 2013. The purpose of this study is to analyze epidemiological and clinical factors of diaphyseal forearm fractures and the results of their treatment with dynamic compression plate (DCP, as well as the complications and therapeutic errors of this surgical technique. The frequency of hospitalization in the trauma-orthopedic department was 3,96%. Ages ranged between 16 and 83, the average age was 32. 132 patients were male (85%. 90% were managed at the day of trauma. Traffic accidents were the most frequent cause in 52% patients. The fracture was in the left forearm in 65% of patients. 53% of fracture lines were in the middle third of the forearm. 38 fractures were open, and 30 were admitted for polytrauma. Osteosynthesis was performed with dynamic compression plate for all patients. In comparison with the literature, our series shows the predominance of young male patients, with traffic accidents being the cause. Osteosynthesis with dynamic compression plate remains the treatment of choice that provides satisfactory results if the accuracy in this technique was respected.

  8. The Effect of Movement Imagery Training on Learning Forearm Pass in Volleyball

    Science.gov (United States)

    Ay, Khitam Mousa; Halaweh, Rami Saleh; Al-Taieb, Mohammad Abu

    2013-01-01

    This study investigates the effect of movement imagery on learning the forearm pass in volleyball. Twenty four mail students from Physical Education Factuly at Jordan University (19 ± 0.5) years of age. After Completed the Movement Imagery Questionnaire-Revised (MIQ-R; Hall & Martin, 1997) the subjects randomly divided into two groups,…

  9. Low-pressure sequential compression of lower limbs enhances forearm skin blood flow.

    Science.gov (United States)

    Amah, Guy; Voicu, Sebastian; Bonnin, Philippe; Kubis, Nathalie

    2016-12-01

    We investigated whether forearm skin blood flow could be improved when a multilayer pulsatile inflatable suit was applied at a low pressure to the lower limbs and abdomen. We hypothesized that a non-invasive purely mechanical stimulation of the lower limbs could induce remote forearm blood flow modifications. The pulsatile suit induced a sequential compartmentalized low compression (65 mmHg), which was synchronized with each diastole of the cardiac cycle with each phase evolving centripetally (lower limbs to abdomen). Modifications of the forearm skin blood flow were continuously recorded by laser Doppler flowmetry (LDF) at baseline and during the pulsatile suit application. Endothelium-dependent and endothelium-independent vasodilations of the forearm skin microcirculation were measured by LDF in response to a local transdermal iontophoretic application of acetylcholine (ACh-test) and to hyperthermia (hyperT- test). Twenty-four healthy volunteers, 12 men and 12 women (43±14 years) were included in the study. LDF responses increased 1) under pulsatile suit (97±106%, p.

  10. Impairment and employment issues after nerve repair in the hand and forearm

    NARCIS (Netherlands)

    Meiners, PM; Coert, JH; Robinson, PH; Meek, MF

    2005-01-01

    Purpose. To evaluate retrospectively subjective impairments, experienced disabilities, job and leisure restrictions and job changes in patients at least 2 years after repair of a peripheral nerve injury in the forearm, wrist or hand. Methods. Between January 1997 and January 2000, 125 patients were

  11. Radial forearm flap : eight years experience with oral and oropharyngeal reconstructions - donor and acceptor site morbidity

    NARCIS (Netherlands)

    Meek, MF; Vermey, A; Robinson, PH; Lichtendahl, DHE; Roodenburg, JLN

    The success rate of 56 free radial forearm flaps used between 1987 and 1995 in the University Hospital Groningen, The Netherlands for oral and oropharyngeal reconstructions in cancer patients, was evaluated. There were 36 men and 20 women. The most prevalent neoplasm was squamous cell carcinoma

  12. Double-layered collagen graft to the radial forearm free flap donor sites without skin graft.

    Science.gov (United States)

    Park, Tae-Jun; Kim, Hong-Joon; Ahn, Kang-Min

    2015-12-01

    Radial forearm free flap is the most reliable flap for intraoral soft tissue reconstruction after cancer ablation surgery. However, unesthetic scar of the donor site and the need for a second donor site for skin graft are major disadvantages of the forearm flap. The purpose of this study was to report the clinical results of double-layered collagen graft to the donor site of the forearm free flap without skin graft. Twenty-two consecutive patients who underwent oral cancer ablation and forearm reconstruction between April 2010 and November 2013 were included in this study. Male to female ratio was 12:10, and average age was 61.0 years old (27-84). Double-layered collagen was grafted to the donor site of the forearm free flap and healed for secondary intention. Upper silicone had been trimmed at the periphery during secondary intention, and dry dressing was used. Postoperative scar healing and esthetic results and function were evaluated. An average follow-up period was 34.9 months. The scar area was decreased to 63.9 % in average. The complete healing was obtained between 1.5 and 3 months according to the defect size. There was no functional defect or impairment 3 months after operation. All patients were satisfied with the esthetic results. Three patients died of recurred cancer. Double-layered collagen graft was successfully performed in this study. Without the thigh skin graft, patients had experienced less painful postoperative healing periods and discomfort.

  13. Decoding subtle forearm flexions using fractal features of surface electromyogram from single and multiple sensors.

    Science.gov (United States)

    Arjunan, Sridhar Poosapadi; Kumar, Dinesh Kant

    2010-10-21

    %. The results show that the MFL and FD of a single channel sEMG recorded from the forearm can be used to accurately identify a set of finger and wrist flexions even when the muscle activity is very weak. A comparison with other features demonstrates that this feature set offers a dramatic improvement in the accuracy of identification of the wrist and finger movements. It is proposed that such a system could be used to control a prosthetic hand or for a human computer interface.

  14. Decoding subtle forearm flexions using fractal features of surface electromyogram from single and multiple sensors

    Directory of Open Access Journals (Sweden)

    Kumar Dinesh

    2010-10-01

    of other features ranged between 58% and 73%. Conclusions The results show that the MFL and FD of a single channel sEMG recorded from the forearm can be used to accurately identify a set of finger and wrist flexions even when the muscle activity is very weak. A comparison with other features demonstrates that this feature set offers a dramatic improvement in the accuracy of identification of the wrist and finger movements. It is proposed that such a system could be used to control a prosthetic hand or for a human computer interface.

  15. Use of intravoxel incoherent motion diffusion-weighted imaging in identifying the vascular and avascular zones of human meniscus.

    Science.gov (United States)

    Guo, Tan; Chen, Juan; Wu, Bing; Zheng, Dandan; Jiao, Sheng; Song, Yan; Chen, Min

    2017-04-01

    To investigate the hypothesis that the intravoxel incoherent motion (IVIM) diffusion-weighted imaging may depict microcirculation of meniscus and the perfusion changes in meniscal disorder. Fifty patients received diffusion-weighted MRI with multiple b-values ranging from 0 to 400 s/mm 2 . The four horns of the menisci were divided into normal, degenerated, and torn groups. IVIM parameters including perfusion fraction (f), pseudo-diffusion coefficient (D*), true diffusion coefficient (D), and the product of f and D* (f D*) of normal meniscal red zone and white zone were derived and compared for microcirculation changes of normal, degenerated, and torn posterior horn of the medial meniscus (PMM). The parameters between red and white zones among the groups were compared. Significant differences were considered when P meniscus and the perfusion changes in meniscal disorder. 3 J. Magn. Reson. Imaging 2017;45:1090-1096. © 2016 International Society for Magnetic Resonance in Medicine.

  16. Relationships between metacarpal morphometry, fore-arm and vertebral bone density and fractures in post-menopausal women

    International Nuclear Information System (INIS)

    Wishart, J.M.; Horowitz, M.; Bochner, M.; Need, A.G.; Nordin, B.E.C.

    1993-01-01

    The relationships between metacarpal morphometric, vertebral and forearm density measurement and the prevalence of vertebral and peripheral fractures were examined in 239 postmenopausal women (median age 63, range 32-84 years). Metacarpal cortical area/total area ratio (CA/TA) was measured with needle calipers forearm mineral density (FMD) by single photon absorptiometry and vertebral mineral density (VMD) by single energy quantitative computed tomography. The authors suggest that metacarpal morphometry, which is widely available at relatively low cost, yields cross-sectional information about bone density and fracture risk, comparable with that obtained by forearm and vertebral densitometry. (Author)

  17. A further study of the high incidence of the median artery of the forearm in Southern Africa.

    Science.gov (United States)

    Henneberg, M; George, B J

    1992-01-01

    Sixty-two forearms from 36 cadavers of South Africans of European extraction were dissected. The frequency of the median artery per forearm was 27.4%. There was neither bilateral difference nor sexual dimorphism in the incidence of the artery. These findings compare well with a previous study of black South Africans (Henneberg & George, 1992) where frequency per forearm was 27.1%. Our findings are much higher than those of earlier studies. This discrepancy may be explained either by differences in the thoroughness of the observations or regional variation, or by the occurrence of a secular trend in the development of vasculature. Images Fig. 1 Fig. 2 PMID:1294564

  18. Continuous Infraclavicular Block for Forearm Amputation After Being Bitten by a Saltwater Crocodile (Crocodylus Porosus: A Case Report

    Directory of Open Access Journals (Sweden)

    Chin-Hsi Chiu

    2009-08-01

    Full Text Available Two important issues after a complete right forearm amputation are replantation and ongoing pain management. There are no reports of successful forearm replantation as a consequence of a crocodile bite. Here, we discuss our pain management in a case of complete forearm amputation after a bite from a saltwater crocodile (Crocodylus porosus, which necessitated six further operations to achieve successful replantation. Continuous infraclavicular brachial plexus block was effective for acute pain control in this case. We strongly recommend performing the block with an indwelling catheter under ultrasound guidance for higher accuracy and safety.

  19. Anatomical and biomechanical study on the interosseous membrane of the cadaveric forearm

    Directory of Open Access Journals (Sweden)

    YI Xian-hong

    2011-06-01

    Full Text Available 【Abstract】 Objective: To study the anatomical and biomechanical features of the interosseous membrane (IOM of the cadaveric forearm. Methods: Ten radius-IOM-ulna structures were har- vested from fresh-frozen cadavers to measure the length, width and thickness of the tendinous portion of IOM. Then, the tendinous portion was isolated along with the ulnar and radial ends to which the tendon attached after measurement. The proximal portion of the radius and the distal portion of the ulna were embedded and fixed in the dental base acrylic resin powder. The embedded specimen was clamped and fixed by the MTS 858 test machine using a 10 000 N load cell for the entire tensile test. IOM was stretched at a speed of 50 mm/min until it was ruptured. The load-displacement curve was depicted with a computer and the maximum load and stiffness were recorded at the same time. Results: The IOM of the forearm was composed of three portions: central tendinous tissue, membranous tis- sue and dorsal affiliated oblique cord. IOM was stretched at a neutral position, and flexed at pronation and supination positions. The tendinous portion of IOM was lacerated in 6 specimens when the point of the maximum load reached to 1 021.50 N± 250.13 N, the stiffness to 138.24 N/m±24.29 N/m, and the length of stretch to 9.77 mm±1.77 mm. Fracture occurred at the fixed end of the ulna before laceration of the tendinous portion in 4 specimens when the maximum load was 744.40 N±109.85 N, the stiffness was 151.17 N/m±30.68 N/m, and the length of the stretch was 6.51 mm±0.51 mm. Conclusions: The IOM of the forearm is a structure having ligamentous characteristics between the radius and the ulna. It is very important for maintenance of the longitu- dinal stability of the forearm. The anatomical and biome- chanical data can be used as an objective criterion for evalu- ating the reconstructive method of IOM of the forearm. Key words: Forearm; Anatomy; Biomechanics

  20. Surface Electromyography of the Forearm Musculature During the Windmill Softball Pitch

    Science.gov (United States)

    Remaley, D. Trey; Fincham, Bryce; McCullough, Bryan; Davis, Kirk; Nofsinger, Charles; Armstrong, Charles; Stausmire, Julie M.

    2015-01-01

    Background: Previous studies investigating the windmill softball pitch have focused primarily on shoulder musculature and function, collecting limited data on elbow and forearm musculature. Little information is available in the literature regarding the forearm. This study documents forearm muscle electromyographic (EMG) activity that has not been previously published. Purpose: Elbow and upper extremity overuse injuries are on the rise in fast-pitch softball pitchers. This study attempts to describe forearm muscle activity in softball pitchers during the windmill softball pitch. Overuse injuries can be prevented if a better understanding of mechanics is defined. Study Design: Descriptive laboratory study. Methods: Surface EMG and high-speed videography was used to study forearm muscle activation patterns during the windmill softball pitch on 10 female collegiate-level pitchers. Maximum voluntary isometric contraction of each muscle was used as a normalizing value. Each subject was tested during a single laboratory session per pitcher. Data included peak muscle activation, average muscle activation, and time to peak activation for 6 pitch types: fastball, changeup, riseball, curveball, screwball, and dropball. Results: During the first 4 phases, muscle activity (seen as signal strength on the EMG recordings) was limited and static in nature. The greatest activation occurred in phases 5 and 6, with increased signal strength, evidence of stretch-shortening cycle, and different muscle characteristics with each pitch style. These 2 phases of the windmill pitch are where the arm is placed in the 6 o’clock position and then at release of the ball. The flexor carpi ulnaris signal strength was significantly greater than the other forearm flexors. Timing of phases 1 through 5 was successively shorter for each pitch. There was a secondary pattern of activation in the flexor carpi ulnaris in phase 4 for all pitches except the fastball and riseball. Conclusion: During the 6

  1. Surface Electromyography of the Forearm Musculature During the Windmill Softball Pitch.

    Science.gov (United States)

    Remaley, D Trey; Fincham, Bryce; McCullough, Bryan; Davis, Kirk; Nofsinger, Charles; Armstrong, Charles; Stausmire, Julie M

    2015-01-01

    Previous studies investigating the windmill softball pitch have focused primarily on shoulder musculature and function, collecting limited data on elbow and forearm musculature. Little information is available in the literature regarding the forearm. This study documents forearm muscle electromyographic (EMG) activity that has not been previously published. Elbow and upper extremity overuse injuries are on the rise in fast-pitch softball pitchers. This study attempts to describe forearm muscle activity in softball pitchers during the windmill softball pitch. Overuse injuries can be prevented if a better understanding of mechanics is defined. Descriptive laboratory study. Surface EMG and high-speed videography was used to study forearm muscle activation patterns during the windmill softball pitch on 10 female collegiate-level pitchers. Maximum voluntary isometric contraction of each muscle was used as a normalizing value. Each subject was tested during a single laboratory session per pitcher. Data included peak muscle activation, average muscle activation, and time to peak activation for 6 pitch types: fastball, changeup, riseball, curveball, screwball, and dropball. During the first 4 phases, muscle activity (seen as signal strength on the EMG recordings) was limited and static in nature. The greatest activation occurred in phases 5 and 6, with increased signal strength, evidence of stretch-shortening cycle, and different muscle characteristics with each pitch style. These 2 phases of the windmill pitch are where the arm is placed in the 6 o'clock position and then at release of the ball. The flexor carpi ulnaris signal strength was significantly greater than the other forearm flexors. Timing of phases 1 through 5 was successively shorter for each pitch. There was a secondary pattern of activation in the flexor carpi ulnaris in phase 4 for all pitches except the fastball and riseball. During the 6 pitches, the greatest muscular activity was in phases 5 and 6

  2. Association between polymorphisms of apolipoprotein E, bone mineral density of the lower forearm, quantitative ultrasound of the calcaneus and osteoporotic fractures in postmenopausal women with hip or lower forearm fracture

    DEFF Research Database (Denmark)

    Sennels, Henriette Pia; Sand, J C; Madsen, B

    2003-01-01

    are contradictory. The aim of this study was to examine the association between polymorphisms of APOE, BMD of the lower forearm, quantitative ultrasound of the calcaneus and osteoporotic fractures in a population of postmenopausal women with hip or lower forearm fractures admitted to a department of orthopaedic...... surgery and age-matched controls from the population register. The APOE genotypes of 327 women were studied: 73 with lower forearm fractures, 43 with hip fractures and 211 age-matched controls. The participants were not receiving antiosteoporotic treatment. Polymerase chain reaction restriction fragment...... length polymorphism (PCR-RFLP) was used to detect the APOE genotypes. Quantitative ultrasound was measured at the calcaneus. Bone mineral density (BMD) of the lower forearm was measured with dual-energy X-ray absorptiometry. The distributions of genotype frequencies in this study were: E2/E2: 0.3%; E2/E3...

  3. Association between polymorphisms of apolipoprotein E, bone mineral density of the lower forearm, quantitative ultrasound of the calcaneus and osteoporotic fractures in postmenopausal women with hip or lower forearm fracture

    DEFF Research Database (Denmark)

    Sennels, Henriette Pia; Sand, J C; Madsen, B

    2003-01-01

    surgery and age-matched controls from the population register. The APOE genotypes of 327 women were studied: 73 with lower forearm fractures, 43 with hip fractures and 211 age-matched controls. The participants were not receiving antiosteoporotic treatment. Polymerase chain reaction restriction fragment...... are contradictory. The aim of this study was to examine the association between polymorphisms of APOE, BMD of the lower forearm, quantitative ultrasound of the calcaneus and osteoporotic fractures in a population of postmenopausal women with hip or lower forearm fractures admitted to a department of orthopaedic....... In conclusion, this study showed no association between bone mass parameters (BMD, speed of sound (SOS), broadband ultrasound attenuation (BUA)), hip or lower forearm fracture and APOE genotypes in a population of postmenopausal women and age-matched controls....

  4. Human otolith-ocular reflexes during off-vertical axis rotation: effect of frequency on tilt-translation ambiguity and motion sickness

    Science.gov (United States)

    Wood, Scott J.; Paloski, W. H. (Principal Investigator)

    2002-01-01

    The purpose of this study was to examine how the modulation of tilt and translation otolith-ocular responses during constant velocity off-vertical axis rotation varies as a function of stimulus frequency. Eighteen human subjects were rotated in darkness about their longitudinal axis 30 degrees off-vertical at stimulus frequencies between 0.05 and 0.8 Hz. The modulation of torsion decreased while the modulation of horizontal slow phase velocity (SPV) increased with increasing frequency. It is inferred that the ambiguity of otolith afferent information is greatest in the frequency region where tilt (torsion) and translational (horizontal SPV) otolith-ocular responses crossover. It is postulated that the previously demonstrated peak in motion sickness susceptibility during linear accelerations around 0.3 Hz is the result of frequency segregation of ambiguous otolith information being inadequate to distinguish between tilt and translation.

  5. Glucocorticoid-induced osteoporosis in the lumbar spine, forearm, and mandible of nephrotic patients

    DEFF Research Database (Denmark)

    Olgaard, K; Storm, Tina; van Wowern, N

    1992-01-01

    /day and tapered down to 20 mg/day for 1 year and DFZ was given in an equipotent dosage. Twenty-three patients completed 6 months of treatment, and 18 patients completed 12 months of treatment. Beside laboratory parameters to ensure the effect of treatment on the nephrotic syndrome, all had measurements......The long-term effects of high dose steroid treatment with either prednisone (PDN) or deflazacort (DFZ) were examined on various parts of the skeleton in 29 patients with nephrotic syndrome. All had normal skeleton at the start of the steroid treatment. At the beginning, PDN was given as 80 mg...... of the bone mineral content (BMC) at 0, 6, and 12 months of treatment. BMC was measured by single photon absorptiometry of both forearms and by dual photon absorptiometry of the mandible, forearms, and lumbar spine. The effect of DFZ was compared to that of PDN due to a potential "calcium sparing" effect...

  6. Risk factors for persistent elbow, forearm and hand pain among computer workers

    DEFF Research Database (Denmark)

    Lassen, C. F.; Mikkelsen, S.; Kryger, Ann Isabel

    2005-01-01

    to elbow, forearm, or wrist-hand pain during the 12 months preceding the baseline questionnaire. Pain status (recovery versus persistence) at follow-up was examined in relation to computer work aspects and ergonomic, psychosocial, and personal factors by questionnaire. In addition, data on objectively......, and type-A behavior, the prognosis seemed independent of psychosocial workplace factors and personal factors. A few cases with severe pain were affected at a level which could be compared to clinical pain conditions. CONCLUSIONS: Our results do not support the hypothesis that computer work activity......OBJECTIVES: This study examined the influence of work-related and personal factors on the prognosis of "severe" elbow, forearm, and wrist-hand pain among computer users. METHODS: In a 1-year follow-up study of 6943 computer users, 673 (10%) participants reported "quite a lot" or more trouble due...

  7. Results of Closed Intramedullary Nailing using Talwarkar Square Nail in Adult Forearm Fractures

    Directory of Open Access Journals (Sweden)

    Nadeem A Lil

    2012-07-01

    Full Text Available The aim of the study was to evaluate results of closed intramedullary nailing using Talwarkar square nails in adult forearm fractures. We prospectively evaluated 34 patients with both bone forearm fractures. The average time to union was 12.8 (SD +3.2 weeks with cast support for a mean of 8.2 weeks. Union was achieved in 31 out of 34 patients. Using the Grace and Eversmann rating system, 17 patients were excellent, 10 were good, and 4 had an acceptable result. Three patients had non-unions, 2 for the radius and one for the ulna. There were two cases of superficial infection, one subject had olecranon bursitis, and one case of radio-ulnar synostosis. Complication rates associated with the use of square nails were lower compared to plate osteosynthesis and locked intramedullary nails. To control rotation post- operatively, there is a need for application of an above-elbow cast after nailing.

  8. Anatomical study of forearm arteries with ultrasound for percutaneous coronary procedures.

    Science.gov (United States)

    Yan, Zhen-xian; Zhou, Yu-jie; Zhao, Ying-xin; Zhou, Zhi-ming; Yang, Shi-wei; Wang, Zhi-jian

    2010-04-01

    In recent years, the radial artery (RA) has become an alternative vascular access site for percutaneous coronary procedures, and the ulnar artery (UA) is another possibility. The objective of this study was to investigate the anatomy of the forearm arteries with ultrasound (US) and to evaluate the effect of the anatomy of the right RA (RRA) on the outcomes of transradial coronary procedures. The 638 patients undergoing transradial coronary procedures were examined with US for measurement of the diameters of the forearm arteries and determination of their anatomical abnormalities before the procedures. The next day the incidence of RA occlusion was recorded. The diameters of the radial and ulnar arteries were similar (P>0.05). The procedure time was longer in patients with anatomical abnormalities (Pforearm arteries of Chinese people are similar. The small diameter and anatomical abnormalities of the RRA could result in longer procedure time, more incidence of procedure failure and RA occlusion.

  9. Commercial golf glove effects on golf performance and forearm muscle activity.

    Science.gov (United States)

    Sorbie, Graeme G; Darroch, Paul; Grace, Fergal M; Gu, Yaodong; Baker, Julien S; Ugbolue, Ukadike C

    2017-01-01

    The study aimed to determine whether or not commercial golf gloves influence performance variables and forearm muscle activity during golf play. Fifteen golfers participated in the laboratory based study, each performing 8 golf swings with a Driver and 7-iron whilst wearing a glove and 8 without wearing the glove. Club head speed, ball speed and absolute carry distance performance variables were calculated. Surface electromyography was recorded from the flexor digitorum superficialis and extensor carpi radialis brevis on both forearm muscles. Club head speed, ball speed and absolute carry distance was significantly higher when using the Driver with the glove in comparison to the Driver without the glove (p < 0.05). No significant differences were evident when using the 7-iron and no significant differences were displayed in muscle activity in either of the conditions. Findings from this study suggest that driving performance is improved when wearing a glove.

  10. Forearm Compartment Syndrome of a Newborn Associated with Extravasation of Contrast Agent

    Directory of Open Access Journals (Sweden)

    Egemen Altan

    2013-01-01

    Full Text Available Extravasation of contrast agents is a possible complication of imaging studies. Although extravasations typically cause minimal swelling or erythema, they can lead to compartment syndrome when the volume of extravasation is high. In this article, we will present an exceptional case where an insignificant amount of contrast agent extravasation led to a forearm compartment syndrome in a newborn, who was treated with an extended fasciotomy. We would like to emphasize the preventive techniques and treatment options of this iatrogenic complication in newborns. Close followup of the patient by the nurses, awareness of the parents and the personnel in the radiology department are the most important preventive measures in this extremity-threatening complication. Forearm compartment syndrome due to contrast agent extravasation may progress more rapidly in newborns even with smaller amounts of extravasation and prompt recognition of the pathology and immediate intervention are unevitable.

  11. Forearm articular proportions and the antebrachial index in Homo sapiens, Australopithecus afarensis and the great apes.

    Science.gov (United States)

    Williams, Frank L'Engle; Cunningham, Deborah L; Amaral, Lia Q

    2015-12-01

    When hominin bipedality evolved, the forearms were free to adopt nonlocomotor tasks which may have resulted in changes to the articular surfaces of the ulna and the relative lengths of the forearm bones. Similarly, sex differences in forearm proportions may be more likely to emerge in bipeds than in the great apes given the locomotor constraints in Gorilla, Pan and Pongo. To test these assumptions, ulnar articular proportions and the antebrachial index (radius length/ulna length) in Homo sapiens (n=51), Gorilla gorilla (n=88), Pan troglodytes (n=49), Pongo pygmaeus (n=36) and Australopithecus afarensis A.L. 288-1 and A.L. 438-1 are compared. Intercept-adjusted ratios are used to control for size and minimize the effects of allometry. Canonical scores axes show that the proximally broad and elongated trochlear notch with respect to size in H. sapiens and A. afarensis is largely distinct from G. gorilla, P. troglodytes and P. pygmaeus. A cluster analysis of scaled ulnar articular dimensions groups H. sapiens males with A.L. 438-1 ulna length estimates, while one A.L. 288-1 ulna length estimate groups with Pan and another clusters most closely with H. sapiens, G. gorilla and A.L. 438-1. The relatively low antebrachial index characterizing H. sapiens and non-outlier estimates of A.L. 288-1 and A.L. 438-1 differs from those of the great apes. Unique sex differences in H. sapiens suggest a link between bipedality and forearm functional morphology. Copyright © 2015 Elsevier GmbH. All rights reserved.

  12. A Compact Forearm Crutch Based on Force Sensors for Aided Gait: Reliability and Validity

    OpenAIRE

    Chamorro-Moriana, Gema; Sevillano, Jos? Luis; Ridao-Fern?ndez, Carmen

    2016-01-01

    Frequently, patients who suffer injuries in some lower member require forearm crutches in order to partially unload weight-bearing. These lesions cause pain in lower limb unloading and their progression should be controlled objectively to avoid significant errors in accuracy and, consequently, complications and after effects in lesions. The design of a new and feasible tool that allows us to control and improve the accuracy of loads exerted on crutches during aided gait is necessary, so as to...

  13. Ulnar variance: its relationship to ulnar foveal morphology and forearm kinematics.

    Science.gov (United States)

    Kataoka, Toshiyuki; Moritomo, Hisao; Omokawa, Shohei; Iida, Akio; Murase, Tsuyoshi; Sugamoto, Kazuomi

    2012-04-01

    It is unclear how individual differences in the anatomy of the distal ulna affect kinematics and pathology of the distal radioulnar joint. This study evaluated how ulnar variance relates to ulnar foveal morphology and the pronosupination axis of the forearm. We performed 3-dimensional computed tomography studies in vivo on 28 forearms in maximum supination and pronation to determine the anatomical center of the ulnar distal pole and the forearm pronosupination axis. We calculated the forearm pronosupination axis using a markerless bone registration technique, which determined the pronosupination center as the point where the axis emerges on the distal ulnar surface. We measured the depth of the anatomical center and classified it into 2 types: concave, with a depth of 0.8 mm or more, and flat, with a depth less than 0.8 mm. We examined whether ulnar variance correlated with foveal type and the distance between anatomical and pronosupination centers. A total of 18 cases had a concave-type fovea surrounded by the C-shaped articular facet of the distal pole, and 10 had a flat-type fovea with a flat surface without evident central depression. Ulnar variance of the flat type was 3.5 ± 1.2 mm, which was significantly greater than the 1.2 ± 1.1 mm of the concave type. Ulnar variance positively correlated with distance between the anatomical and pronosupination centers. Flat-type ulnar heads have a significantly greater ulnar variance than concave types. The pronosupination axis passes through the ulnar head more medially and farther from the anatomical center with increasing ulnar variance. This study suggests that ulnar variance is related in part to foveal morphology and pronosupination axis. This information provides a starting point for future studies investigating how foveal morphology relates to distal ulnar problems. Copyright © 2012 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  14. Topical Retinol Restores Type I Collagen Production in Photoaged Forearm Skin within Four Weeks

    Directory of Open Access Journals (Sweden)

    Min Sun

    2016-09-01

    Full Text Available Production of type I collagen (COL1, the major structural protein of the skin, declines during aging, leading to skin thinning and becoming fragile, which increases the risk of bruising and wound healing disorders in the elderly. Topical treatments that can restore COL1 synthesis and ultimately COL1 content in aged skin hold promise to improve skin health. Much effort has been spent on developing agents that can safely and effectively enhance COL1 synthesis in aged skin. However, how fast and to what extent COL1 production in aged skin can be enhanced by a topical treatment remains unclear. Herein, we investigated a four-week topical retinol (ROL treatment. A one-day occlusion of ROL (0.4% or vehicle was applied on photoaged forearms of elderly (>65 years old subjects once a week for four weeks. Vehicle was also applied on forearms of young (23–33 years subjects in the same manner. Skin samples were obtained one week after the last treatment and analyzed for COL1 synthesis. We found that the ROL treatment increased the level of COL1 mRNA (2.3-fold and proCOL1 protein (1.8-fold in photoaged forearms to levels similar to that of young forearms within four weeks. Our study proves the concept that reduced COL1 production in aged skin can be readily restored. In addition, our study provides an evidence-based foundation for developing COL1-enhancing topical agents, and establishes a reliable and practical efficacy test for evaluating such agents.

  15. Epithelioid Sarcoma of the Forearm Arising from Perineural Sheath of Median Nerve Mimicking Carpal Tunnel Syndrome

    Directory of Open Access Journals (Sweden)

    Hiromasa Fujii

    2009-01-01

    Full Text Available We report here a case of epithelioid sarcoma in the forearm of a 33-year-old male presenting with symptoms and signs of carpal tunnel syndrome originating from the direct involvement of the median nerve. Due to the slow growing of the tumor, the patient noticed the presence of tumor mass in his forearm after several months from the initial onset of the symptoms. Magnetic resonance imaging showed an 8×4 cm mass involving the median nerve in the middle part of the forearm, and histological analysis of the biopsy specimen revealed the diagnosis of epithelioid sarcoma. Radical surgical resection was performed in conjunction with adjuvant chemotherapy. The function of the flexors were restored by the multiple tendon transfers (EIP→FDS; ECRL→FDP; BrR→FPL; EDM→opponens with superficial cutaneous branch of radial nerve transfer to the resected median nerve. The function of the affected hand showed excellent with the DASH disability/symptom score of 22.5, and both the grasp power and sensory of the median nerve area has recovered up to 50% of the normal side. The patient returned to his original vocation and alive with continuous disease free at 3.5-year follow-up since initial treatment.

  16. Suppression of the reactive hyperemic response in the forearm due to local hand cooling.

    Science.gov (United States)

    Kilgour, R D; Carranza, A; Findlay, R

    1997-01-01

    Forearm blood flow (FBF) was measured by electrical impedance plethysmography in order to identify the influence of local cooling of the contralateral hand after 3 min of arterial occlusion. Ten volunteers (six females, four males) were randomly assigned to the following three experimental conditions on separate days: a) 6 min of local hand cooling (5-7 degrees C); b) 3 min of arterial occlusion of the forearm; and c) combined arterial occlusion and local cooling. All subjects experienced the typical pressor response during 6 min of hand cooling as evidenced by the significant increase (p forearm vascular resistance (FVR = MAP/FBF) made an initial drop during the first 30 s of cooling and then gradually rose to reach peak levels between 5-6 min of cooling. With respect to the hyperemic response, FBF significantly increased (p cooling, FBF increased above baseline values and reached peak levels during the initial 30 s of the post-occlusion period. However, the magnitude of the hyperemic response was significantly lower in the cold condition compared to the hyperemia alone (3.20 +/- 0.42 vs 6.75 +/- 0.64 ml x 100 ml-1.min-1; p cooling had an overriding effect on the factors that promote peripheral vasodilation following brief periods (3 min) of arterial occlusion.

  17. Long-term outcome of forearm flee-flap phalloplasty in the treatment of transsexualism.

    Science.gov (United States)

    Leriche, Albert; Timsit, Marc-Olivier; Morel-Journel, Nicolas; Bouillot, André; Dembele, Diala; Ruffion, Alain

    2008-05-01

    To assess the long-term outcome of forearm free-flap phalloplasty in transsexuals, as obtaining a satisfying neophallus in female-to-male transsexuals is a surgical challenge. We analysed retrospectively 56 transsexuals who had a phalloplasty using a radial forearm free-flap in our department from 1986 to 2002. The complication rate was assessed by regular examination. Patient satisfaction was evaluated by a questionnaire about cosmetic aspects, sexual life and overall satisfaction. The mean follow up was 110 months; 53 of the 56 patients (95%) currently have a neophallus, after a mean of six surgical procedures. Satisfaction was assessed in 53 patients using a specific questionnaire: 51 (93%) of the patients reported that the phalloplasty allowed them to accord their physical appearance with their feeling of masculinity. There were flap complications in 14 patients (25%); three (5%) flaps were lost, with one each due to early haematoma, cellulitis and late arterial thrombosis. The other 11 flap complications were all transitory, e.g. infection, haematomas and vascular thrombosis. There were prosthesis complications in 11 of 38 patients (29%). Moreover, seven of 19 patients (37%) who had a urethroplasty presented with complex strictures and fistulae that led to perineal urethrostomy. Our study shows that phalloplasty with a forearm free-flap leads to good results in term of flap survival and patient satisfaction. However, there was a high rate of complications. Patients must be clearly informed that the procedure can seldom be achieved in one stage.

  18. Proximal forearm extensor muscle strain is reduced when driving nails using a shock-controlled hammer.

    Science.gov (United States)

    Buchanan, Kimberly A; Maza, Maria; Pérez-Vázquez, Carlos E; Yen, Thomas Y; Kijowski, Richard; Liu, Fang; Radwin, Robert G

    2016-10-01

    Repetitive hammer use has been associated with strain and musculoskeletal injuries. This study investigated if using a shock-control hammer reduces forearm muscle strain by observing adverse physiological responses (i.e. inflammation and localized edema) after use. Three matched framing hammers were studied, including a wood-handle, steel-handle, and shock-control hammer. Fifty volunteers were randomly assigned to use one of these hammers at a fatiguing pace of one strike every second, to seat 20 nails in a wood beam. Magnetic resonance imaging was used to scan the forearm muscles for inflammation before the task, immediately after hammering, and one to two days after. Electromyogram signals were measured to estimate grip exertions and localized muscle fatigue. High-speed video was used to calculate the energy of nail strikes. While estimated grip force was similar across the three hammers, the shock-control hammer had 40% greater kinetic energy upon impact and markedly less proximal extensor muscle edema than the wood-handle and steel-handle hammers, immediately after use (phandle shock can mitigate strain in proximal forearm extensor muscles. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Supinated forearm is correlated with the onset of medial epicondylitis in professional slalom water-skiers.

    Science.gov (United States)

    Rosa, Donato; Di Donato, Sigismondo Luca; Balato, Giovanni; D'Addona, Alessio; Schonauer, Fabrizio

    2016-01-01

    prolonged and laborious activities involving wrists and forearms has been long associated with the onset of epicondylitis. Slalom water-skiing can be included in this category. The purpose of the study is to analyse the correlation between the pronated or supinated position of forearms during water-skiing practice and the presence respectively of lateral and medial epicondylitis. sixty-six pro and semi-pro slalom water-skiers were enrolled in the study. A questionnaire was submitted to each athlete. Diagnosis of lateral or medial epicondylitis was made through anamnesis and clinical exam by an expert orthopaedic surgeon. Chi-squared were performed for categorical variables, and Mann-Whitney U test for continuous ones. from 116 upper limbs examined, we observed 15 (12.9%) cases of lateral epicondylitis, 30 (25.9%) cases of medial epicondylitis, 10 (8.6%) were affected by both lateral and medial epicondylitis. Lateral and medial epicondylitis were associated (95% C.I.=2,489-26,355; P=epicondylitis (95% C.I.=1,529-9,542; P=0.003). slalom water-skiing can be considered a high-risk sport for epicondylitis. In slalom water-skiers there is a correlation between development of lateral and medial epicondylitis in the same upper limb. Supinated position of forearms is strongly associated with the diagnosis of medial epicondylitis.

  20. The effect of nerve blockade on forearm and finger skin blood flow during body heating and cooling.

    Science.gov (United States)

    Saumet, J L; Degoute, C S; Saumet, M; Abraham, P

    1992-08-01

    To determine the role of the active cutaneous vasodilatator response in forearm and finger skin, direct assessment of only skin blood flow was performed before and after musculocutaneous and median nerve blockade during whole body heating and cooling. Forearm laser Doppler flow (LDF forearm), forearm heat thermal clearance (HTC forearm), and finger laser Doppler flow (LDF finger) were monitored in the nerve blocked skin and contralateral untreated skin (control). In the pre-blockade period, no significant differences were found between experimental and control arm skin. After nerve block a significant increase occurred only in LDF finger, which rose from 4.3 +/- 0.6 to 6.0 +/- 0.5 volts (p less than 0.05). During whole body heating LDF forearm and HTC forearm increased significantly on both arms. The increase in LDF forearm was greater (p less than 0.05) in control (18.3 +/- 1.2 volts) than in nerve blocked skin (14.6 +/- 1.8 volts) and occurred earlier. The same tendency was observed in HTC forearm between nerve blocked skin (0.522 +/- 0.06 W.m-1.degrees C-1) and control 0.671 +/- 0.037 W.m-1.degrees C-1) (NS). LDF raise up to 6.6 +/- 0.5 and 6.8 +/- 0.5 volts in the blocked finger and in the control respectively. During cooling LDF finger in the control decreased to 1.3 +/- 0.1 volt and was significantly (p less than 0.05) lower than in the resting period, and lower than that in the nerve blocked finger (3.4 +/- 0.8 volts) (p less than 0.05). We conclude that the active vasodilatator system plays an important role as far as the timing and the amplitude of the cutaneous vasodilatator response to whole body heating in the forearm but not in the finger. At thermal neutrality, the vascular vasoconstrictor tone is high to the finger but not to the forearm. The vasoconstrictor response to cooling occurred only in the finger.

  1. Radial forearm free flap morbidity: A rare case of a normal preoperative arteriogram and acute intraoperative hand ischemia

    OpenAIRE

    Bruner, Terrence W; Hanasono, Matthew M; Skoracki, Roman J

    2011-01-01

    The radial forearm free flap is ideal for reconstructive microsurgery due to its thin, pliable fasciocutaneous tissue, reliable anatomy and ease and simplicity of flap elevation. However, one of the major complications is hand ischemia due to sacrifice of the radial artery, although it is a rare occurrence. A case involving a 73-year-old man who developed intraoperative hand ischemia after elevation of a radial forearm free flap is presented.

  2. The Effects of Forearm Support on Upper Body for People in Front of Monitor: A Meta-Analysis.

    Science.gov (United States)

    Lyu, Jingtong; Wu, Xiaojing; Duan, Xin; Xiang, Zhou

    2015-01-01

    With the ever-growing number of people who work at visual display terminals, the work-related musculoskeletal disorders of the upper body are believed to be an important problem all over the world. The forearm support, which can keep the forearm and wrist in biomechanical posture, is a possible protective factor of the development of upper body syndrome. This meta-analysis examines the efficacy of forearm support in reducing upper body syndrome. The Cochrane Library, EMBASE, Ovid, ScienceDirect, SpringerLink, Google Scholar, CNKI database, and Wanfang database were searched from inception until May 29, 2013. Relevant studies were included after the screening of title, abstract, and the full text. Impact of bias was assessed independently by 2 authors. Four studies that met all the inclusion criteria were included finally. The combined results based on all studies suggested that statistically the forearm support had a nonsignificant effect on upper body syndrome (odds ratio [OR] = 0.70, 95% confidence interval [CI]: 0.49, 1.02). The result of subgroup analysis suggested that forearm support has a significant effect on neck or shoulder syndrome (OR = 0.70, 95% CI: 0.43, 1.14) and the effect on upper extremity syndrome (OR = 0.76, 95% CI: 0.49, 1.19) is not significant. This meta-analysis suggested that the forearm support had statistically nonsignificant effect on preventing upper body syndrome on the whole.

  3. Short-term sensory and cutaneous vascular responses to therapeutic ultrasound in the forearms of healthy volunteers.

    Science.gov (United States)

    Shaik, Shaguftha Sultana; MacDermid, Joy C; Birmingham, Trevor; Grewal, Ruby; Farooq, Baseer

    2014-01-01

    Therapeutic ultrasound (US) is used for a variety of clinical pathologies and is thought to accelerate tissue repair and help with pain reduction via its thermal and nonthermal effects. The evidence on physiological effects of US on both sensory and vascular functions in humans is incomplete. Hence, the purpose of this study was to determine the short-term impact of two doses of US (3 MHz, 1:4, 0.25 W/cm(2), 5 min; 1 MHz, continuous, 0.8 W/cm(2), 3 min), on sensory and vascular responses in the healthy forearms. Twenty healthy subjects were recruited (mean age, 29.6 ± 8.8 years) for the study. Superficial blood flow (SBF) in the distal forearms was determined using the tissue viability imaging system. Sensory perception thresholds (SPT) were determined from ring finger (C7, C8) to assess A-beta (at 2,000 Hz) and C fiber function (at 5 Hz), using a Neurometer CPT/C device. Subject's two hands were randomly allocated to group order (AB/BA). Scores were obtained before and immediately after the application of US and control. Differences in these were analyzed using repeated measures. Both 3 MHz pulsed US and 1 MHz continuous US showed small to moderate (effect size = 0.12 to 0.68), statistically significant reductions in SBF (3 MHz, mean change = 2.8 AU and 1 MHz, mean change = 3.9 AU, p 0.05). Age and gender also had no effect on all outcome measures (p > 0.05). This study demonstrated minor reductions in skin blood flow, skin temperatures, and C fiber perception thresholds immediately after 3 MHz, and 1 MHz US. The responses observed may have been due to a thermo-cooling effect of the gel or due to the direct effect of US on C fibers of median and ulnar nerves. US had a negligible effect on A-beta fibres. This would suggest that future studies looking at physiological effects of US should move towards investigating larger dosages and study the effects in patient populations.

  4. Highly stretchable strain sensor based on polyurethane substrate using hydrogen bond-assisted laminated structure for monitoring of tiny human motions

    Science.gov (United States)

    Huang, Ying; Zhao, Yunong; Wang, Yang; Guo, Xiaohui; Zhang, Yangyang; Liu, Ping; Liu, Caixia; Zhang, Yugang

    2018-03-01

    Strain sensors used as flexible and wearable electronic devices have improved prospects in the fields of artificial skin, robotics, human-machine interfaces, and healthcare. This work introduces a highly stretchable fiber-based strain sensor with a laminated structure made up of a graphene nanoplatelet layer and a carbon black/single-walled carbon nanotube synergetic conductive network layer. An ultrathin, flexible, and elastic two-layer polyurethane (PU) yarn substrate was successively deposited by a novel chemical bonding-based layered dip-coating process. These strain sensors demonstrated high stretchability (˜350%), little hysteresis, and long-term durability (over 2400 cycles) due to the favorable tensile properties of the PU substrate. The linearity of the strain sensor could reach an adjusted R-squared of 0.990 at 100% strain, which is better than most of the recently reported strain sensors. Meanwhile, the strain sensor exhibited good sensibility, rapid response, and a lower detection limit. The lower detection limit benefited from the hydrogen bond-assisted laminated structure and continuous conductive path. Finally, a series of experiments were carried out based on the special features of the PU strain sensor to show its capacity of detecting and monitoring tiny human motions.

  5. Study of cyclic and steady particle motion in a realistic human airway model using phase-Doppler anemometry

    Science.gov (United States)

    Jedelský, Jan; Lízal, František; Jícha, Miroslav

    2012-04-01

    Transport and deposition of particles in human airways has been of research interest for many years. Various experimental methods such as constant temperature anemometry, particle image velocimetry and laser-Doppler based techniques were employed for study of aerosol transport in the past. We use Phase-Doppler Particle Analyser (P/DPA) for time resolved size and velocity measurement of liquid aerosol particles in a size range 1 to 8 μm. The di-2ethylhexyl sabacate (DEHS) particles were produced by condensation monodisperse aerosol generator. A thin-wall transparent model of human airways with non-symmetric bifurcations and non-planar geometry containing parts from throat to 3rd-4th generation of bronchi was fabricated for the study. Several cyclic (sinusoidal) breathing regimes were simulated using pneumatic breathing mechanism. Analogous steady-flow regimes were also investigated and used for comparison. An analysis of the particle velocity data was performed with aim to gain deeper understanding of the transport phenomena in the realistic bifurcating airway system. Flows of particles of different sizes in range 1 - 10 μm was found to slightly differ for extremely high Stokes numbers. Differences in steady and cyclic turbulence intensities were documented in the paper. Systematically higher turbulence intensity was found for cyclic flows and mainly in the expiration breathing phase. Negligible differences were found for behaviour of different particle size classes in the inspected range 1 to 8 μm. Possibility of velocity spectra estimation of air flow using the P/DPA data is discussed.

  6. Study of cyclic and steady particle motion in a realistic human airway model using phase-Doppler anemometry

    Directory of Open Access Journals (Sweden)

    Jícha Miroslav

    2012-04-01

    Full Text Available Transport and deposition of particles in human airways has been of research interest for many years. Various experimental methods such as constant temperature anemometry, particle image velocimetry and laser-Doppler based techniques were employed for study of aerosol transport in the past. We use Phase-Doppler Particle Analyser (P/DPA for time resolved size and velocity measurement of liquid aerosol particles in a size range 1 to 8 μm. The di-2ethylhexyl sabacate (DEHS particles were produced by condensation monodisperse aerosol generator. A thin-wall transparent model of human airways with non-symmetric bifurcations and non-planar geometry containing parts from throat to 3rd-4th generation of bronchi was fabricated for the study. Several cyclic (sinusoidal breathing regimes were simulated using pneumatic breathing mechanism. Analogous steady-flow regimes were also investigated and used for comparison. An analysis of the particle velocity data was performed with aim to gain deeper understanding of the transport phenomena in the realistic bifurcating airway system. Flows of particles of different sizes in range 1 – 10 μm was found to slightly differ for extremely high Stokes numbers. Differences in steady and cyclic turbulence intensities were documented in the paper. Systematically higher turbulence intensity was found for cyclic flows and mainly in the expiration breathing phase. Negligible differences were found for behaviour of different particle size classes in the inspected range 1 to 8 μm. Possibility of velocity spectra estimation of air flow using the P/DPA data is discussed.

  7. Displacement of the medial meniscus within the passive motion characteristics of the human knee joint: an RSA study in human cadaver knees.

    NARCIS (Netherlands)

    Tienen, T. van; Buma, P.; Scholten, J.G.; Kampen, A. van; Veth, R.P.H.; Verdonschot, N.J.J.

    2005-01-01

    The objective of this study was to validate an in vitro human cadaver knee-joint model for the evaluation of the meniscal movement during knee-joint flexion. The question was whether our model showed comparable meniscal displacements to those found in earlier meniscal movement studies in vivo.

  8. Differences in blood pressure measurements in the forearm and upper arm of obese otherwise healthy first year medical students

    Directory of Open Access Journals (Sweden)

    Suganthi V, Navin Rajaratnam, Suzanne Maria D’cruz

    2014-07-01

    Full Text Available Background: The prevalence of obesity is increasing in Indian youth and obesity is associated with complications like systemic hypertension. Often, due to the non-availability of appropriate sized cuffs, standard cuff bladders are used to measure blood pressure in the forearms of obese young adults. Aim: To compare the upper arm arterial blood pressure measured using an appropriate cuff with the forearm arterial blood pressure measured using a standard cuff and conventional sphygmomanometry in obese otherwise healthy first year medical students. Materials and Methods: Blood pressure was measured in 27 obese otherwise healthy first year medical students after five minutes of rest using a mercury sphygmomanometer with the subjects seated and the arm and forearm at heart level, using an appropriate sized cuff for the upper arm according to American Heart Association standards and a standard cuff for the fore arm. Results: A statistically significant difference in both systolic [t-test (paired = -6.921; df = 26; sig = .000 (2- tailed] and diastolic blood pressure [t-test (paired = -8.508; df = 26; sig = .000 (2- tailed] was found, with the blood pressure readings being higher in the forearm. The correlations between upper arm and forearm systolic and diastolic blood pressure were 0.785 (p = .000 and 0.870 (p = .000. Conclusion: Both systolic and diastolic blood pressure measurements were significantly higher in the forearm. Further studies with larger sample size should be conducted to confirm that forearm blood pressure measurements using standard cuff bladders cannot be considered equal to upper arm measurements made using an appropriate sized cuff in all young obese individuals

  9. Cooling hyperthermic firefighters by immersing forearms and hands in 10 degrees C and 20 degrees C water.

    Science.gov (United States)

    Giesbrecht, Gordon G; Jamieson, Christopher; Cahill, Farrell

    2007-06-01

    Firefighters experience significant heat stress while working with heavy gear in a hot, humid environment. This study compared the cooling effectiveness of immersing the forearms and hands in 10 and 20 degrees C water. Six men (33 +/- 10 yr; 180 +/- 4 cm; 78 +/- 9 kg; 19 +/- 5% body fat) wore firefighter 'turn-out gear' (heavy clothing and breathing apparatus weighing 27 kg) in a protocol including three 20-min exercise bouts (step test, 78 W, 40 degrees C air, 40% RH) each followed by a 20-min rest/cooling (21 degrees C air); i.e., 60 min of exercise, 60 min of cooling. Turn-out gear was removed during rest/cooling periods and subjects either rested (Control), immersed their hands in 10 or 20 degrees C water (H-10, H-20), or immersed their hands and forearms in 10 or 20 degrees C water (HF-10, HF-20). In 20 degrees C water, hand immersion did not reduce core temperature compared with Control; however, including forearm immersion decreased core temperature below Control values after both the second and final exercise periods (p hand immersion produced a lower core temperature (0.8 degrees C above baseline) than all other conditions (1.1 to 1.4 degrees C above baseline) after the final exercise period (p Hand and forearm immersion in cool water is simple, reduces heat strain, and may increase work performance in a hot, humid environment. With 20 degrees C water, forearms should be immersed with the hands to be effective. At lower water temperatures, forearm and/or hand immersion will be effective, although forearm immersion will decrease core temperature further.

  10. Motion sensing energy controller

    International Nuclear Information System (INIS)

    Saphir, M.E.; Reed, M.A.

    1984-01-01

    A moving object sensing processor responsive to slowly varying motions of a human being or other moving object in a zone of interest employs high frequency pulse modulated non-visible radiation generated by a radiation generating source, such as an LED, and detected by a detector sensitive to radiation of a preselected wavelength which generates electrical signals representative of the reflected radiation received from the zone of interest. The detectorsignals are processed to normalize the base level and remove variations due to background level changes, and slowly varying changes in the signals are detected by a bi-polar threshold detector. The control signals generated by the threshold detector in response to slowly varying motion are used to control the application of power to a utilization device, such as a set of fluoroescent lights in a room, the power being applied in response to detection of such motion and being automatically terminated in the absence of such motion after a predetermined time period established by a settable incrementable counter

  11. Assessment of pepper spray product potency in Asian and Caucasian forearm skin using transepidermal water loss, skin temperature and reflectance colorimetry.

    Science.gov (United States)

    Pershing, Lynn K; Reilly, Christopher A; Corlett, Judy L; Crouch, Dennis J

    2006-01-01

    Historically, pepper spray product potency has been established using a taste test evaluation. A taste test is subjective and may not be appropriate for assessing pepper potency in skin. The current study evaluated chemically diverse pepper sprays in human forearm skin using three objective, noninvasive parameters: transepidermal water loss, skin surface temperature and erythema, as a means for assessing dermal pharmacology, toxicology and product potency. Five commercial pepper spray products containing various capsaicinoid analogs at various concentrations were evaluated in duplicate on volar forearms of six Caucasians and six Asians using a 10 min exposure. Mean surface skin temperature, transepidermal water loss results were highly variable and therefore did not demonstrate dose responsive behavior to increasing capsaicinoid concentrations. Erythema, as measured by increases in a* (reflected light in the red-to-green color spectrum) of the L*a*b* uniform color scale, was superior among parameters evaluated in discriminating pepper spray potency and correlated well with the relative and total capsaicinoid concentration in the products. Products containing greater than 16 mg ml(-1) capsaicinoid concentration produced greater erythema responses in Caucasians than Asians. Asians responded greater to the synthetic analog, nonivamide, than to mixtures of capsaicinoids, while Caucasians responded equally to both capsaicinoid analogs. Thus, pepper spray product potency in human skin reflects the total capsaicinoid concentration, the specific capsaicin analog(s) present, and the race of the individual exposed. The finding that the reflectance colorimeter a* scale can differentiate these parameters in skin will have a significant impact on evaluating the use and efficacy of pepper spray products in humans. 2005 John Wiley & Sons, Ltd.

  12. Screen printing of a capacitive cantilever-based motion sensor on fabric using a novel sacrificial layer process for smart fabric applications

    International Nuclear Information System (INIS)

    Wei, Yang; Torah, Russel; Yang, Kai; Beeby, Steve; Tudor, John

    2013-01-01

    Free-standing cantilevers have been fabricated by screen printing sacrificial and structural layers onto a standard polyester cotton fabric. By printing additional conductive layers, a complete capacitive motion sensor on fabric using only screen printing has been fabricated. This type of free-standing structure cannot currently be fabricated using conventional fabric manufacturing processes. In addition, compared to conventional smart fabric fabrication processes (e.g. weaving and knitting), screen printing offers the advantages of geometric design flexibility and the ability to simultaneously print multiple devices of the same or different designs. Furthermore, a range of active inks exists from the printed electronics industry which can potentially be applied to create many types of smart fabric. Four cantilevers with different lengths have been printed on fabric using a five-layer structure with a sacrificial material underneath the cantilever. The sacrificial layer is subsequently removed at 160 °C for 30 min to achieve a freestanding cantilever above the fabric. Two silver electrodes, one on top of the cantilever and the other on top of the fabric, are used to capacitively detect the movement of the cantilever. In this way, an entirely printed motion sensor is produced on a standard fabric. The motion sensor was initially tested on an electromechanical shaker rig at a low frequency range to examine the linearity and the sensitivity of each design. Then, these sensors were individually attached to a moving human forearm to evaluate more representative results. A commercial accelerometer (Microstrain G-link) was mounted alongside for comparison. The printed sensors have a similar motion response to the commercial accelerometer, demonstrating the potential of a printed smart fabric motion sensor for use in intelligent clothing applications. (paper)

  13. Screen printing of a capacitive cantilever-based motion sensor on fabric using a novel sacrificial layer process for smart fabric applications

    Science.gov (United States)

    Wei, Yang; Torah, Russel; Yang, Kai; Beeby, Steve; Tudor, John

    2013-07-01

    Free-standing cantilevers have been fabricated by screen printing sacrificial and structural layers onto a standard polyester cotton fabric. By printing additional conductive layers, a complete capacitive motion sensor on fabric using only screen printing has been fabricated. This type of free-standing structure cannot currently be fabricated using conventional fabric manufacturing processes. In addition, compared to conventional smart fabric fabrication processes (e.g. weaving and knitting), screen printing offers the advantages of geometric design flexibility and the ability to simultaneously print multiple devices of the same or different designs. Furthermore, a range of active inks exists from the printed electronics industry which can potentially be applied to create many types of smart fabric. Four cantilevers with different lengths have been printed on fabric using a five-layer structure with a sacrificial material underneath the cantilever. The sacrificial layer is subsequently removed at 160 °C for 30 min to achieve a freestanding cantilever above the fabric. Two silver electrodes, one on top of the cantilever and the other on top of the fabric, are used to capacitively detect the movement of the cantilever. In this way, an entirely printed motion sensor is produced on a standard fabric. The motion sensor was initially tested on an electromechanical shaker rig at a low frequency range to examine the linearity and the sensitivity of each design. Then, these sensors were individually attached to a moving human forearm to evaluate more representative results. A commercial accelerometer (Microstrain G-link) was mounted alongside for comparison. The printed sensors have a similar motion response to the commercial accelerometer, demonstrating the potential of a printed smart fabric motion sensor for use in intelligent clothing applications.

  14. The Etiology and Treatment of the Softened Phallus after the Radial Forearm Osteocutaneous Free Flap Phalloplasty

    Directory of Open Access Journals (Sweden)

    Seok-Kwun Kim

    2012-07-01

    Full Text Available BackgroundThe radial forearm osteocutaneous free flap is considered to be the standard technique for penile construction. One year after their operation, most patients experience a softened phallus, so that they suffer from difficulties in sexual intercourse. In this report, we present our experience with phalloplasty by radial forearm osteocutaneous free flap, as well as an evaluation of the etiology and treatment of the softened phallus.MethodsBetween March 2005 and February 2010, 58 patients underwent phalloplasty by radial forearm osteocutaneous free flap. Most of their neophallus had been softened subjectively and among them, 12 patients who wanted correction were investigated. We performed repetitive fat injection, artificial dermis grafting, silicone rod insertion, and rib bone with cartilaginous tip graft. Physical examination, plain radiograph, computed tomography, bone scintigraphy, and satisfaction scores were investigated.ResultsMost of the participants' penises have been softened after phalloplasty, and the skin elasticity had been also decreased. On plain radiograph, the distal end of the bone was self-rounded; however, the bone shape of the neophallus had no significant interval changes or resorption. Computed tomography showed equivocal density of cortical bone. On bone scintigraphy, the bone metabolism was active at 3 months postoperatively, and remained active 9 years postoperatively.ConclusionsThe use of a rib bone with cartilaginous tip graft could be an option for improvement of the softened phallus. Silicon rod insertion is also worth considering for rigidity of the softened phallus. Decreased rigidity due to soft tissue atrophy could be alleviated with repeated fat injection and artificial dermis grafting.

  15. No impaired hemoglobin oxygenation in forearm muscles of patients with chronic CRPS-1.

    Science.gov (United States)

    Brunnekreef, Jaap J J; Oosterhof, Jan; Wolff, André P; Crul, Ben J P; Wilder-Smith, Oliver H G; Oostendorp, Rob A B

    2009-01-01

    Physiotherapy is considered an important treatment option in patients with upper limb complex regional pain syndrome type-1 (CRPS-1). In case of chronic CRPS-1, exercise therapy of the affected limb forms an important part of the physiotherapeutic program. We investigated whether muscle loading in chronic CRPS-1 patients is associated with impairments in muscle circulation of the forearm of the affected limb. Thirty patients with chronic CRPS-1 unilaterally affecting their upper limbs, and 30 age-matched and sex-matched control participants were included in this study. Local muscle blood flow and hemoglobin oxygenation were measured by near infrared spectroscopy within the muscles of the forearm at rest, after 1-minute isometric handgrip exercises, and after arterial occlusion. Main outcome parameters were: local muscle blood flow, O2 consumption (mVO2), and postischemic reoxygenation (ReOx). We found no differences in baseline muscle blood flow, mVO2, and ReOx between the affected CRPS-1, unaffected CRPS-1, and control arms. After exercise, mVO2 of the affected CRPS-1 arms was not different from the clinically unaffected CRPS-1 arms. Furthermore, in comparison with the control arms, unaffected CRPS-1 arms showed no difference in mVO2 or ReOx. Muscle loading does not seems to be related to impairments in muscle oxygen uptake in forearm muscles of upper limbs affected by chronic CRPS-1. Our results suggest that exercise therapy can be safely used in physiotherapeutic training programs for chronic CRPS-1 of the upper limb.

  16. Forearm cutaneous vascular and sudomotor responses to whole body passive heat stress in young smokers.

    Science.gov (United States)

    Moyen, Nicole E; Anderson, Hannah M; Burchfield, Jenna M; Tucker, Matthew A; Gonzalez, Melina A; Robinson, Forrest B; Ganio, Matthew S

    2015-07-01

    The purpose of this study was to compare smokers and nonsmokers' sudomotor and cutaneous vascular responses to whole body passive heat stress. Nine regularly smoking (SMK: 29 ± 9 yr; 10 ± 6 cigarettes/day) and 13 nonsmoking (N-SMK: 27 ± 8 yr) males were passively heated until core temperature (TC) increased 1.5°C from baseline. Forearm local sweat rate (LSR) via ventilated capsule, sweat gland activation (SGA), sweat gland output (SGO), and cutaneous vasomotor activity via laser-Doppler flowmetry (CVC) were measured as mean body temperature increased (ΔTb) during passive heating using a water-perfused suit. Compared with N-SMK, SMK had a smaller ΔTb at the onset of sweating (0.52 ± 0.19 vs. 0.35 ± 0.14°C, respectively; P = 0.03) and cutaneous vasodilation (0.61 ± 0.21 vs. 0.31 ± 0.12°C, respectively; P body heating was higher in N-SMK vs. SMK (1.00 ± 0.13 vs. 0.79 ± 0.26 mg·cm(-2)·min(-1); P = 0.03), which was likely a result of higher SGO (8.94 ± 3.99 vs. 5.94 ± 3.49 μg·gland(-1)·min(-1), respectively; P = 0.08) and not number of SGA (104 ± 7 vs. 121 ± 9 glands/cm(2), respectively; P = 0.58). During whole body passive heat stress, smokers had an earlier onset for forearm sweating and cutaneous vasodilation, but a lower local sweat rate that was likely due to lower sweat output per gland. These data provide insight into local (i.e., forearm) thermoregulatory responses of young smokers during uncompensatory whole body passive heat stress. Copyright © 2015 the American Physiological Society.

  17. Temporal and spatiotemporal variability in comprehensive forearm skin microcirculation assessment during occlusion protocols.

    Science.gov (United States)

    Strömberg, Tomas; Sjöberg, Folke; Bergstrand, Sara

    2017-09-01

    Forearm skin hyperemia during release after brachial occlusion has been proposed for evaluating peripheral arterial disease and endothelial dysfunction. We used a novel fiberoptic system integrating Laser Doppler Flowmetry and Diffuse Reflectance Spectroscopy for a comprehensive pointwise model based microcirculation characterization. The aim was to evaluate and compare the temporal and the spatiotemporal variabilities in forearm skin microcirculation parameters (speed resolved perfusion; low speed 10mm/s, and total perfusion (Perf SR, tot ); the concentration and oxygenation of red blood cells, C RBC and S O2 ). Ten healthy subjects underwent arterial and venous forearm occlusions (AO, VO), repeated within one week. The repeatability was calculated as the coefficient of variation (CV) and the agreement as the intra-class correlation coefficient (ICC). The temporal CVs for conventional perfusion, Perf conv , Perf SR, tot , C RBC and S O2 were 14%, 12%, 9% and 9%, respectively, while the ICC were >0.75 (excellent). The perfusion measures generally had a higher spatiotemporal than temporal variability, which was not the case for S O2 and C RBC . The corresponding spatiotemporal CVs were 33%, 32%, 18% and 15%, respectively. During VO, C RBC had a CV0.40 (fair-good), and after release this was the case for C RBC (AO and VO), S O2 (VO) and Perf SR, fair-good agreement were: C RBC during and after release of VO, the Perf SR, value of these parameters in discriminating endothelial function remains to be studied. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Reliability of Free Radial Forearm Flap for Tongue Reconstruction Following Oncosurgical Resection

    Directory of Open Access Journals (Sweden)

    Gaurab Ranjan Chaudhuri

    2015-08-01

    Full Text Available Introduction Primary closure following oncosurgical resection of carcinoma tongue has been found to compromise tongue function in regards to speech and swallowing very badly. In contrast, reconstruction of tongue with free radial forearm flap following oncosurgical resection has shown promising functional outcome. Materials and Methods Thirteen patients (ten male and three female with squamous cell carcinoma involving anterior 2/3rd of tongue had undergone either hemiglossectomy or subtotal glossectomy. Reconstruction was done with free radial forearm flap following oncosurgical resection and neck dissection. All of them received postoperative radiotherapy. Follow-up ranged from 2 months to 2 years. The age of the patients ranged between 32 and 65 years. Flap dimension ranged from 7x6 cm to 10x8 cm. Vascular anastomosis performed in an end-to-end manner with 8-0 Ethilon® under loupe magnifiacation. Results Venous congestion occurred in one patient after 48 hours postoperatively and the flap underwent complete necrosis on postoperative day 5. Postoperative hematoma was found in one patient within first 24 hours of reconstruction. Re-exploration was done immediately, blood clots were removed. No fresh bleeding point was seen and the flap survived. In this series, 12 out of 13 flaps survived completely (92%. Conclusion The free radial forearm flap has become a workhorse flap in head and reconstruction due to its lack of extra bulk, relative ease of dissection, long vascular pedicle, good calibre vessels, malleability and minimal donor site morbidity. Furthermore its low flap loss and complication rate offer the best choice for tongue reconstruction.

  19. The emerging trend of non-operative treatment in paediatric type I open forearm fractures.

    Science.gov (United States)

    Zhang, H; Fanelli, M; Adams, C; Graham, J; Seeley, M

    2017-08-01

    Open fractures are considered an orthopaedic emergency and are generally an indication for operative debridement. Recent studies have questioned this approach for the management of Gustilo-Anderson Type I open fractures in the paediatric population. This meta-analysis studies the non-operative management of Type I open paediatric forearm fractures. An Ovid MEDLINE and PubMed database literature search was performed for studies that involved a quantified number of Gustilo-Anderson Type I open forearm fractures in the paediatric population, which were treated without operative intervention. A fixed-effect meta-analysis, weighting each study based on the number of patients, and a pooled estimate of infection risk (with 95% confidence interval (CI)) was performed. The search results yielded five studies that were eligible for inclusion. No included patients had operative debridement and all were treated with antibiotics. The number of patients in each study ranged from 3 to 45, with a total of 127 paediatric patients in the meta-analysis. The infection rate was 0% for all patients included. The meta-analysis estimated a pooled infection risk of 0% (95% CI 0 to 2.9). The five included studies had a total of 127 patients with no cases of infection after non-operative management of Type I open paediatric forearm fractures. The infection rate of Type I fractures among operatively managed patients is 1.9%. The trend in literature towards non-operative treatment of paediatric Type I open fractures holds true in this meta-analysis.

  20. [Reconstruction of oral mucosa with a micro-vascularized fascia-cutaneous flap from the forearm].

    Science.gov (United States)

    Burgueño García, Miguel; Cebrián Carretero, José Luis; Muñoz Caro, Jesús Manuel; Arias Gallo, Javier

    2002-01-01

    Epidermoid carcinoma of jugal mucosa is an aggressive tumor. Its treatment is based on broad excision and reconstruction in order to avoid fibrosis and restriction of mouth opening. Neck dissection and radiotherapy are indicated in selected cases. We display our experience with microvascularized flaps with the aim of preventing the flaws. We reconsider 8 patients (representing 10 flaps) handle in our Department. Besides we discuss other therapeutic alternatives after the growth's removal. The conclusion reached is that the mucovascularized forearm flaps give a great quantity of thin tissue and therefore so results to be the best option for the reconstruction of the jugal mucosa.

  1. Thermogenic response to epinephrine in the forearm and abdominal subcutaneous adipose tissue

    DEFF Research Database (Denmark)

    Simonsen, L; Bülow, J; Madsen, Jan Lysgård

    1992-01-01

    Whole body energy expenditure, thermogenic and metabolic changes in the forearm, and intercellular glucose concentrations in subcutaneous adipose tissue on the abdomen determined by microdialysis were measured during epinephrine infusion in healthy subjects. After a control period, epinephrine...... was infused at rates of 0.2 and 0.4 nmol.kg-1 x min-1. Whole body resting energy expenditure was 4.36 +/- 0.56 (SD) kJ/min. Energy expenditure increased to 5.14 +/- 0.74 and 5.46 +/- 0.79 kJ/min, respectively (P

  2. A 61-year-old man with erythematous forearm papules three months after liver transplantation.

    Science.gov (United States)

    Ayrapetyan, Mesrop; Googe, Paul B; Jolly, Puneet; Levinson, Kara; Popowitch, Elena; Lachiewicz, Anne M

    2018-06-01

    A 61-year-old Caucasian man presented with papules on his left forearm and hand three months after liver transplantation: images from physical exam, pathology, and microbiology are presented. Skin biopsy confirmed the presence of fungal elements within the hair shaft, which is consistent with Majocchi granuloma, also known as nodular granulomatous perifolliculitis. A combination of fungal culture, microscopic morphology, and gene sequencing was used to identify the causative organism. The patient recovered with appropriate systemic antifungal therapy. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. A case of primary extracranial meningioma of the forearm with bone invasion

    Energy Technology Data Exchange (ETDEWEB)

    Murata, Hideki [Self-Defense Force Fuji Hospital, Division of Orthopaedic Surgery, Oyama-cho, Sunto-gun, Shizuoka (Japan); Takahashi, Mitsuru; Takagi, Tatsuya; Katagiri, Hirohisa [Shizuoka Cancer Center Hospital, Division of Orthopaedic Oncology, Nagaizumi-cho, Sunto-gun, Shizuoka (Japan); Ito, Ichiro [Shizuoka Cancer Center Hospital, Division of Pathology, Nagaizumi-cho, Sunto-gun, Shizuoka (Japan); Ishida, Tsuyoshi [Kohnodai Hospital, Department of Pathology and Laboratory Medicine, National Center of Neurology and Psychiatry, Ichikawa, Chiba (Japan)

    2007-06-15

    We report here a rare case of primary extracranial meningioma in a 73-year-old woman with an asymptomatic mass located in the left distal-dorsal forearm. MRI revealed the lesion to be poorly circumscribed and unclear, with iso-signal intensity to muscle on T1 and with a relatively high signal intensity on T2-weighted imaging. The histopathology of the specimen from incision biopsy was typical of meningioma, showing bland spindle cell proliferation with a whorling pattern. Immunohistochemically, the tumor cells were positive for epithelial membrane antigen and vimentin, and negative for S-100 expression. (orig.)

  4. EVALUATION OF RESULTS IN FRACTURES OF BOTH BONES FOREARM TREATED WITH DYNAMIC COMPRESSION PLATING

    Directory of Open Access Journals (Sweden)

    Sindhuja G

    2017-06-01

    Full Text Available BACKGROUND The anatomical alignment of the bones, the length, the radial bow, and axis should be restored for a good functional outcome. Conservative treatment has resulted in malunion, non-union, synostosis and ultimately poor functional outcome. Internal fixation helps in perfect reduction of fracture fragments in anatomical position by rigid fixation and early mobilisation, the normal functions of the hand can be re-achieved at the earliest. This study has been taken up to evaluate the results of open reduction and internal fixation of the fractures of BBFA with DCP in adults and its advantages and complications. In this study, the rate and time taken for union, the complication, the functional results in terms of forearm rotation and wrist and elbow movements are evaluated. MATERIALS AND METHODS This study includes treatment of 20 cases of fracture of both bones of forearm by open reduction and internal fixation with 3.5 mm DCP from August 2013 to August 2015 at Department of Orthopaedics at Konaseema Institute of Medical Sciences, Amalapuram. Follow-up was done up to September 2015. This is a prospective time bound study. Sample size - 20 patients. Inclusion Criteria- 1. Simple fractures. 2. Open fractures-Gustilo and Anderson type I and type II. 3. Age criteria = 15 to 70 years, both males and females. Exclusion Criteria- 1. Age criteria 0 to 14 years & > 70 years. 2. Radiologically proven segmental fractures and isolated forearm bone fractures. 3. Pathological fracture. 4. Gustilo and Anderson type III. 5. Patient not willing for surgery. 6. Patient unfit for surgery. RESULTS The present study consists of 20 cases of fracture both bones of the forearm. All the cases were openly reduced and internally fixed with 3.5 mm DCP. The study period was from August 2013 to September 2015. The age of these patients ranged from 15-70 years with fracture being most common in 3 rd decade and an average age of 31 years. CONCLUSION Use of separate

  5. Extradigital glomic tumor of the forearm. About a case and review of literature.

    Science.gov (United States)

    Lancien, U; Duteille, F; Perrot, P

    2018-04-01

    We report the clinical case of a 72-year-old man followed for 10years by a specialized pain center, for neuropathic pain poorly systematized, triggered by the contact of the anteromedial face of the right forearm. After surgical excision, histological analysis indicated a well-circumscribed nodule in the subcutaneous region, confirming that the mass was a glomus tumor. In this clinical case, surgical excision allowed an immediate disappearance of the pains without recurrence to this day. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  6. An electromyographic study of the effect of hand grip sizes on forearm muscle activity and golf performance.

    Science.gov (United States)

    Sorbie, Graeme G; Hunter, Henry H; Grace, Fergal M; Gu, Yaodong; Baker, Julien S; Ugbolue, Ukadike Chris

    2016-01-01

    The study describes the differences in surface electromyography (EMG) activity of two forearm muscles in the lead and trail arm at specific phases of the golf swing using a 7-iron with three different grip sizes among amateur and professional golfers. Fifteen right-handed male golfers performed five golf swings using golf clubs with three different grip sizes. Surface EMG was used to measure muscle activity of the extensor carpi radialis brevis (ECRB) and flexor digitorum superficialis (FDS) on both forearms. There were no significant differences in forearm muscle activity when using the three golf grips within the group of 15 golfers (p > 0.05). When using the undersize grip, club head speed significantly increased (p = 0.044). During the backswing and downswing phases, amateurs produced significantly greater forearm muscle activity with all three grip sizes (p < 0.05). In conclusion, forearm muscle activity is not affected by grip sizes. However, club head speed increases when using undersize grips.

  7. A comparative study of vascular injection fluids in fresh-frozen and embalmed human cadaver forearms

    NARCIS (Netherlands)

    Doomernik, D.E.; Kruse, R.R.; Reijnen, M.M.; Kozicz, T.; Kooloos, J.G.M.

    2016-01-01

    Over the years, various vascular injection products have been developed to facilitate anatomical dissections. This study aimed to compare the most commonly used vascular injection products in fresh-frozen and formalin-embalmed cadaver specimens. An overview of the properties, advantages and

  8. The direct, not V1-mediated, functional influence between the thalamus and middle temporal complex in the human brain is modulated by the speed of visual motion.

    Science.gov (United States)

    Gaglianese, A; Costagli, M; Ueno, K; Ricciardi, E; Bernardi, G; Pietrini, P; Cheng, K

    2015-01-22

    The main visual pathway that conveys motion information to the middle temporal complex (hMT+) originates from the primary visual cortex (V1), which, in turn, receives spatial and temporal features of the perceived stimuli from the lateral geniculate nucleus (LGN). In addition, visual motion information reaches hMT+ directly from the thalamus, bypassing the V1, through a direct pathway. We aimed at elucidating whether this direct route between LGN and hMT+ represents a 'fast lane' reserved to high-speed motion, as proposed previously, or it is merely involved in processing motion information irrespective of speeds. We evaluated functional magnetic resonance imaging (fMRI) responses elicited by moving visual stimuli and applied connectivity analyses to investigate the effect of motion speed on the causal influence between LGN and hMT+, independent of V1, using the Conditional Granger Causality (CGC) in the presence of slow and fast visual stimuli. Our results showed that at least part of the visual motion information from LGN reaches hMT+, bypassing V1, in response to both slow and fast motion speeds of the perceived stimuli. We also investigated whether motion speeds have different effects on the connections between LGN and functional subdivisions within hMT+: direct connections between LGN and MT-proper carry mainly slow motion information, while connections between LGN and MST carry mainly fast motion information. The existence of a parallel pathway that connects the LGN directly to hMT+ in response to both slow and fast speeds may explain why MT and MST can still respond in the presence of V1 lesions. Copyright © 2014 IBRO. Published by Elsevier Ltd. All rights reserved.

  9. Whole body and forearm substrate metabolism in hyperthyroidism: evidence of increased basal muscle protein breakdown.

    Science.gov (United States)

    Riis, Anne Lene Dalkjaer; Jørgensen, Jens Otto Lunde; Gjedde, Signe; Nørrelund, Helene; Jurik, Anne Grethe; Nair, K S; Ivarsen, Per; Weeke, Jørgen; Møller, Niels

    2005-06-01

    Thyroid hormones have significant metabolic effects, and muscle wasting and weakness are prominent clinical features of chronic hyperthyroidism. To assess the underlying mechanisms, we examined seven hyperthyroid women with Graves' disease before (Ht) and after (Eut) medical treatment and seven control subjects (Ctr). All subjects underwent a 3-h study in the postabsorptive state. After regional catheterization, protein dynamics of the whole body and of the forearm muscles were measured by amino acid tracer dilution technique using [15N]phenylalanine and [2H4]tyrosine. Before treatment, triiodothyronine was elevated (6.6 nmol/l) and whole body protein breakdown was increased 40%. The net forearm release of phenylalanine was increased in hyperthyroidism (microg.100 ml(-1).min(-1)): -7.0 +/- 1.2 Ht vs. -3.8 +/- 0.8 Eut (P = 0.04), -4.2 +/- 0.3 Ctr (P = 0.048). Muscle protein breakdown, assessed by phenylalanine rate of appearance, was increased (microg.100 ml(-1).min(-1)): 15.5 +/- 2.0 Ht vs. 9.6 +/- 1.4 Eut (P = 0.03), 9.9 +/- 0.6 Ctr (P = 0.02). Muscle protein synthesis rate did not differ significantly. Muscle mass and muscle function were decreased 10-20% before treatment. All abnormalities were normalized after therapy. In conclusion, our results show that hyperthyroidism is associated with increased muscle amino acid release resulting from increased muscle protein breakdown. These abnormalities can explain the clinical manifestations of sarcopenia and myopathy.

  10. An Unusual Metastasis of a Transglottic Squamous Cell Carcinoma to the Forearm

    Directory of Open Access Journals (Sweden)

    Abdullah Dafir Albeyatti

    2013-01-01

    Full Text Available Introduction. Each year around 2,200 people in the UK are diagnosed with laryngeal SCC (Office of National Statistics 2009. Compared to pharyngeal carcinoma, it is a highly curable disease with a survival rate of around 60% for all stages and all forms of treatment. Case Presentation. We present the case of a 60-year-old man with a previously treated T4 N2c transglottic squamous cell carcinoma (SCC, who developed an isolated swelling in the extensor compartment of his right forearm at 6 months after radical laryngectomy with bilateral neck dissection. Fine needle aspiration of the forearm lesion revealed SCC consistent with a metastasis from the laryngeal primary. MRI revealed that the lesion was confined to the muscle. Initial staging CT showed no distant metastases or signs of advanced disease, including no evidence of axillary nodal involvement. Conclusion. This case is therefore unusual, as one of only 2 cases reported in the scientific literature of isolated distant muscular metastasis from a laryngeal squamous cell carcinoma. We conclude that any muscular swelling, in the setting of previous head and neck malignancy, should be treated with a high degree of suspicion for metastasis and investigated promptly.

  11. A Compact Forearm Crutch Based on Force Sensors for Aided Gait: Reliability and Validity.

    Science.gov (United States)

    Chamorro-Moriana, Gema; Sevillano, José Luis; Ridao-Fernández, Carmen

    2016-06-21

    Frequently, patients who suffer injuries in some lower member require forearm crutches in order to partially unload weight-bearing. These lesions cause pain in lower limb unloading and their progression should be controlled objectively to avoid significant errors in accuracy and, consequently, complications and after effects in lesions. The design of a new and feasible tool that allows us to control and improve the accuracy of loads exerted on crutches during aided gait is necessary, so as to unburden the lower limbs. In this paper, we describe such a system based on a force sensor, which we have named the GCH System 2.0. Furthermore, we determine the validity and reliability of measurements obtained using this tool via a comparison with the validated AMTI (Advanced Mechanical Technology, Inc., Watertown, MA, USA) OR6-7-2000 Platform. An intra-class correlation coefficient demonstrated excellent agreement between the AMTI Platform and the GCH System. A regression line to determine the predictive ability of the GCH system towards the AMTI Platform was found, which obtained a precision of 99.3%. A detailed statistical analysis is presented for all the measurements and also segregated for several requested loads on the crutches (10%, 25% and 50% of body weight). Our results show that our system, designed for assessing loads exerted by patients on forearm crutches during assisted gait, provides valid and reliable measurements of loads.

  12. A Compact Forearm Crutch Based on Force Sensors for Aided Gait: Reliability and Validity

    Directory of Open Access Journals (Sweden)

    Gema Chamorro-Moriana

    2016-06-01

    Full Text Available Frequently, patients who suffer injuries in some lower member require forearm crutches in order to partially unload weight-bearing. These lesions cause pain in lower limb unloading and their progression should be controlled objectively to avoid significant errors in accuracy and, consequently, complications and after effects in lesions. The design of a new and feasible tool that allows us to control and improve the accuracy of loads exerted on crutches during aided gait is necessary, so as to unburden the lower limbs. In this paper, we describe such a system based on a force sensor, which we have named the GCH System 2.0. Furthermore, we determine the validity and reliability of measurements obtained using this tool via a comparison with the validated AMTI (Advanced Mechanical Technology, Inc., Watertown, MA, USA OR6-7-2000 Platform. An intra-class correlation coefficient demonstrated excellent agreement between the AMTI Platform and the GCH System. A regression line to determine the predictive ability of the GCH system towards the AMTI Platform was found, which obtained a precision of 99.3%. A detailed statistical analysis is presented for all the measurements and also segregated for several requested loads on the crutches (10%, 25% and 50% of body weight. Our results show that our system, designed for assessing loads exerted by patients on forearm crutches during assisted gait, provides valid and reliable measurements of loads.

  13. Bone and muscular anatomy of the forearm and hand in Tapirus terrestris (Perissodactyla, Tapiridae

    Directory of Open Access Journals (Sweden)

    Saulo Gonçalves Pereira

    2017-05-01

    Full Text Available In Brazil, there are two species of tapirs, the largest land mammals in Brazil, which belong to the order Perissodactyla, as do horses. Our aim was to describe the bone and muscular anatomy of the forearm and hand in T. terrestris and to propose adaptive functions. We used five anatomical specimens donated from a breeder to the Laboratory for Teaching and Research on Wild Animals of the Federal University of Uberlandia after death with no trauma. The bones were analyzed, the muscles dissected, and both described. The bones of the forearm and hand of the tapir are the ulna, radius, Os. metacarpalia, Os. carpi, phalanx and Os. sesamoideum. The muscles are M. extensor carpi radialis, M. ulnaris lateralis; M. flexor carpi radialis; M. extensor radialis communis; M. extensor digitorum longus II, III, IV and V, M. extensor digitorum lateralis; M. extensor digitorum; M. abductor longus; M. flexor digiti superficialis; M. flexor digitalis; M. flexor carpi ulnaris; M. flexor carpi obliquus; and M. interossei and M. lumbricales. Characteristics of bone and muscle structure are adapted to the development of the animal’s niche.

  14. Bone and muscular anatomy of the forearm and hand in Tapirus terrestris (Perissodactyla, Tapiridae

    Directory of Open Access Journals (Sweden)

    Saulo Gonçalves Pereira

    2017-05-01

    Full Text Available http://dx.doi.org/10.5007/2175-7925.2017v30n2p35 In Brazil, there are two species of tapirs, the largest land mammals in Brazil, which belong to the order Perissodactyla, as do horses. Our aim was to describe the bone and muscular anatomy of the forearm and hand in T. terrestris and to propose adaptive functions. We used five anatomical specimens donated from a breeder to the Laboratory for Teaching and Research on Wild Animals of the Federal University of Uberlandia after death with no trauma. The bones were analyzed, the muscles dissected, and both described. The bones of the forearm and hand of the tapir are the ulna, radius, Os. metacarpalia, Os. carpi, phalanx and Os. sesamoideum. The muscles are M. extensor carpi radialis, M. ulnaris lateralis; M. flexor carpi radialis; M. extensor radialis communis; M. extensor digitorum longus II, III, IV and V, M. extensor digitorum lateralis; M. extensor digitorum; M. abductor longus; M. flexor digiti superficialis; M. flexor digitalis; M. flexor carpi ulnaris; M. flexor carpi obliquus; and M. interossei and M. lumbricales. Characteristics of bone and muscle structure are adapted to the development of the animal’s niche.

  15. Objective assessment of plaster cast quality in pediatric distal forearm fractures: Is there an optimal index?

    Science.gov (United States)

    Labronici, Pedro José; Ferreira, Leonardo Termis; Dos Santos Filho, Fernando Claudino; Pires, Robinson Esteves Santos; Gomes, Davi Coutinho Fonseca Fernandes; da Silva, Luiz Henrique Penteado; Gameiro, Vinicius Schott

    2017-02-01

    Several so-called casting indices are available for objective evaluation of plaster cast quality. The present study sought to investigate four of these indices (gap index, padding index, Canterbury index, and three-point index) as compared to a reference standard (cast index) for evaluation of plaster cast quality after closed reduction of pediatric displaced distal forearm fractures. Forty-three radiographs from patients with displaced distal forearm fractures requiring manipulation were reviewed. Accuracy, sensitivity, specificity, false-positive probability, false-negative probability, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio were calculated for each of the tested indices. Comparison among indices revealed diagnostic agreement in only 4.7% of cases. The strongest correlation with the cast index was found for the gap index, with a Spearman correlation coefficient of 0.94. The gap index also displayed the best agreement with the cast index, with both indices yielding the same result in 79.1% of assessments. When seeking to assess plaster cast quality, the cast index and gap index should be calculated; if both indices agree, a decision on quality can be made. If the cast and gap indices disagree, the padding index can be calculated as a tiebreaker, and the decision based on the most frequent of the three results. Calculation of the three-point index and Canterbury index appears unnecessary. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. The effects of a new designed forearm orthosis in treatment of lateral epicondylitis.

    Science.gov (United States)

    Forogh, Bijan; Khalighi, Mohsen; Javanshir, Mohammad Ali; Ghoseiri, Kamiar; Kamali, Mohammad; Raissi, Gholamreza

    2012-07-01

    This paper reports on the design and testing of a new designed forearm orthosis and explores its efficacious in comparison to the standard counterforce orthosis in patients with lateral epicondylitis. Twenty-four patients were enrolled in this assessor-blinded clinical trial and randomly assigned to two parallel treatment groups. The measures of pain and function, the pain threshold and grip strength were compared using patient rated tennis elbow evaluation (PRTEE) form, algometer and dynamometer respectively at baseline and 4 weeks after treatment. Paired and independent t-test statistical methods recruited for within and between groups comparisons respectively. The both orthoses, counterforce and new-designed, significantly relieved pain, and improved function, pain threshold and grip strength of all patients after 4 weeks application. The new-designed orthosis seemed to be more effective than the counterforce orthosis in pain relief, but there was not any significant difference in efficacious of two types of orthoses regarding function. The new-designed orthosis can significantly relieve pain, improve function, increase pain threshold and grip strength after application. This orthosis seemed to be more effective than counterforce orthosis in relieving pain and increasing the pain threshold probably due to the limitation of forearm supination.

  17. Ultrasound in the diagnosis of a median neuropathy in the forearm: case report

    Directory of Open Access Journals (Sweden)

    Yoon Joon-Shik

    2007-12-01

    Full Text Available Abstract Background Electrodiagnostic studies are traditionally used in the diagnosis of focal neuropathies, however they lack anatomical information regarding the nerve and its surrounding structures. The purpose of this case is to show that high-resolution ultrasound used as an adjunct to electrodiagnostic studies may complement this lack of information and give insight to the cause. Case presentation A 60-year-old male patient sustained a forearm traction injury resulting in progressive weakness and functional loss in the first three digits of the right hand. High-resolution ultrasound showed the presence of an enlarged nerve and a homogenous soft-tissue structure appearing to engulf the nerve. The contralateral side was normal. Surgery revealed fibrotic bands emanating from the flexor digitorum profundus muscle compressing the median nerve thus confirming the ultrasound findings. Conclusion A diagnostically challenging case of median neuropathy in the forearm is presented in which high-resolution ultrasound was valuable in establishing an anatomic etiology and directing appropriate management.

  18. Auditory Motion Elicits a Visual Motion Aftereffect

    Directory of Open Access Journals (Sweden)

    Christopher C. Berger

    2016-12-01

    Full Text Available The visual motion aftereffect is a visual illusion in which exposure to continuous motion in one direction leads to a subsequent illusion of visual motion in the opposite direction. Previous findings have been mixed with regard to whether this visual illusion can be induced cross-modally by auditory stimuli. Based on research on multisensory perception demonstrating the profound influence auditory perception can have on the interpretation and perceived motion of visual stimuli, we hypothesized that exposure to auditory stimuli with strong directional motion cues should induce a visual motion aftereffect. Here, we demonstrate that horizontally moving auditory stimuli induced a significant visual motion aftereffect—an effect that was driven primarily by a change in visual motion perception following exposure to leftward moving auditory stimuli. This finding is consistent with the notion that visual and auditory motion perception rely on at least partially overlapping neural substrates.

  19. Auditory Motion Elicits a Visual Motion Aftereffect.

    Science.gov (United States)

    Berger, Christopher C; Ehrsson, H Henrik

    2016-01-01

    The visual motion aftereffect is a visual illusion in which exposure to continuous motion in one direction leads to a subsequent illusion of visual motion in the opposite direction. Previous findings have been mixed with regard to whether this visual illusion can be induced cross-modally by auditory stimuli. Based on research on multisensory perception demonstrating the profound influence auditory perception can have on the interpretation and perceived motion of visual stimuli, we hypothesized that exposure to auditory stimuli with strong directional motion cues should induce a visual motion aftereffect. Here, we demonstrate that horizontally moving auditory stimuli induced a significant visual motion aftereffect-an effect that was driven primarily by a change in visual motion perception following exposure to leftward moving auditory stimuli. This finding is consistent with the notion that visual and auditory motion perception rely on at least partially overlapping neural substrates.

  20. Auditory motion capturing ambiguous visual motion

    Directory of Open Access Journals (Sweden)

    Arjen eAlink

    2012-01-01

    Full Text Available In this study, it is demonstrated that moving sounds have an effect on the direction in which one sees visual stimuli move. During the main experiment sounds were presented consecutively at four speaker locations inducing left- or rightwards auditory apparent motion. On the path of auditory apparent motion, visual apparent motion stimuli were presented with a high degree of directional ambiguity. The main outcome of this experiment is that our participants perceived visual apparent motion stimuli that were ambiguous (equally likely to be perceived as moving left- or rightwards more often as moving in the same direction than in the opposite direction of auditory apparent motion. During the control experiment we replicated this finding and found no effect of sound motion direction on eye movements. This indicates that auditory motion can capture our visual motion percept when visual motion direction is insufficiently determinate without affecting eye movements.

  1. No effect of forearm band and extensor strengthening exercises for the treatment of tennis elbow: a prospective randomised study.

    Science.gov (United States)

    Luginbühl, Rolf; Brunner, Florian; Schneeberger, Alberto G

    2008-01-01

    The objective of this prospective randomised study was to analyse the effect of the forearm support band and of strengthening exercises for the treatment of tennis elbow. Twenty-nine patients with 30 tennis elbows were randomised into 3 groups of treatment: (I) forearm support band, (II) strengthening exercises and (III) both methods. The patients had a standardised examination at their first visit, and then after 6 weeks, 3 months and 1 year. At the latest follow-up, there was a significant improvement of the symptoms compared to before treatment (p<0.0001), considering all patients independently of the methods of treatment. However, no differences in the scores were found between the 3 groups of treatment (p=0.27), indicating that no beneficial influence was found either for the strengthening exercises or for the forearm support band. Improvement seems to occur with time, independent of the method of treatment used.

  2. Implementation of a forearm support to reduce the amount of irradiated lung and heart in radiation therapy of the breast

    International Nuclear Information System (INIS)

    Hurkmans, Coen W.; Borger, Jacques H.; Giersbergen, Aline van; Cho, John; Mijnheer, Ben J.

    2001-01-01

    We compared simulator images of medial tangential fields taken in two positions: (1) with the ipsilateral arm abducted, holding a 'L-bar' armrest and (2) with both arms extended above the head in a forearm support. The average maximum heart distance as well as the central lung distance decreased significantly by 3.4 (SE 0.9) and 4.7 (SE 1.1) mm, respectively, when the new forearm support was used. The estimated normal tissue complication probability for excess cardiac mortality decreased by on average 3.1% (SE 1.3%). For some patients, a greater amount of the axilla was included in the field. We recommend the use of the forearm support during breast cancer treatment with tangential fields to decrease the amount of heart and lung inside the fields

  3. Congenital Deficiency of Distal Ulna and Dislocation of the Radial Head Treated by Single Bone Forearm Procedure

    Directory of Open Access Journals (Sweden)

    Paragjyoti Gogoi

    2014-01-01

    Full Text Available Congenital deficiency of part of distal ulna affecting the distal radio-ulnar joint is a rare disorder. It is even rarer to find the association of proximal radio-ulnar joint dislocation along with distal ulnar deficiency. This type of congenital forearm anomaly is difficult to treat. Conversion to a single bone forearm in the expense of pronation-supination movement is a viable option. By doing so the elbow and wrist can be stabilized; however movement is possible in only one plane. We are describing here a girl of 8 years having proximal radio-ulnar joint dislocation along with deficiency of distal ulna treated by converting into a single bone forearm.

  4. Determination of energy absorbed during X-ray exposure of the forearm by means of thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Hofmann, E.

    1982-01-01

    LiF dose meters were used to determine radiation doses in conventional X-ray diagnostic pictures of the forearm. The paper describes a method for determining integral doses by using these dose meters. It describes in detail how a phantom forearm apt for the purpose is to be made. In the Federal Republic of Germany, malignant growth incidence due to X-ray pictures of the forearm is enhanced by about .01 cases each year. The malignant growth incidence rate caused by X-ray diagnostic measures is low. It is therefore generally justified to neglect limbs in exemplary studies of radiation exposure. All calculations and considerations took into account that all possible radiation protection measures have been duly applied. (orig./DG) [de

  5. A Novel Method for Estimation of Femoral Neck Bone Mineral Density Using Forearm Images from Peripheral Cone Beam Computed Tomography

    Directory of Open Access Journals (Sweden)

    Kwanmoon Jeong

    2016-04-01

    Full Text Available The main goal of osteoporosis treatment is prevention of osteoporosis-induced bone fracture. Dual-energy X-ray absorptiometry (DXA and quantitative computed tomographic imaging (QCT are widely used for assessment of bone mineral density (BMD. However, they have limitations in patients with special conditions. This study evaluated a method for diagnosis of osteoporosis using peripheral cone beam computed tomography (CBCT to estimate BMD. We investigated the correlation between the ratio of cortical and total bone areas of the forearm and femoral neck BMD. Based on the correlation, we established a linear transformation between the ratio and femoral neck BMD. We obtained forearm images using CBCT and femoral neck BMDs using dual-energy X-ray absorptiometry (DXA for 23 subjects. We first calculated the ratio of the cortical to the total bone area in the forearm from the CBCT images, and investigated the relationship with the femoral neck BMDs obtained from DXA. Based on this relationship, we further investigated the optimal forearm region to provide the highest correlation coefficient. We used the optimized forearm region to establish a linear transformation of the form to estimate femoral neck BMD from the calculated ratio. We observed the correlation factor of r = 0.857 (root mean square error = 0.056435 g/cm2; mean absolute percentage error = 4.5105% between femoral neck BMD and the ratio of the cortical and total bone areas. The strongest correlation was observed for the average ratios of the mid-shaft regions of the ulna and radius. Our results suggest that femoral neck BMD can be estimated from forearm CBCT images and may be useful for screening osteoporosis, with patients in a convenient sitting position. We believe that peripheral CBCT image-based BMD estimation may have significant preventative value for early osteoporosis treatment and management.

  6. Implementation of Human-Machine Synchronization Control for Active Rehabilitation Using an Inertia Sensor

    Directory of Open Access Journals (Sweden)

    Zhibin Song

    2012-11-01

    Full Text Available According to neuro-rehabilitation practice, active training is effective for mild stroke patients, which means these patients are able to recovery effective when they perform the training to overcome certain resistance by themselves. Therefore, for rehabilitation devices without backdrivability, implementation of human-machine synchronization is important and a precondition to perform active training. In this paper, a method to implement this precondition is proposed and applied in a user’s performance of elbow flexions and extensions when he wore an upper limb exoskeleton rehabilitation device (ULERD, which is portable, wearable and non-backdrivable. In this method, an inertia sensor is adapted to detect the motion of the user’s forearm. In order to get a smooth value of the velocity of the user’s forearm, an adaptive weighted average filtering is applied. On the other hand, to obtain accurate tracking performance, a double close-loop control is proposed to realize real-time and stable tracking. Experiments have been conducted to prove that these methods are effective and feasible for active rehabilitation.

  7. Influence of Visual Motion, Suggestion, and Illusory Motion on Self-Motion Perception in the Horizontal Plane.

    Science.gov (United States)

    Rosenblatt, Steven David; Crane, Benjamin Thomas

    2015-01-01

    A moving visual field can induce the feeling of self-motion or vection. Illusory motion from static repeated asymmetric patterns creates a compelling visual motion stimulus, but it is unclear if such illusory motion can induce a feeling of self-motion or alter self-motion perception. In these experiments, human subjects reported the perceived direction of self-motion for sway translation and yaw rotation at the end of a period of viewing set visual stimuli coordinated with varying inertial stimuli. This tested the hypothesis that illusory visual motion would influence self-motion perception in the horizontal plane. Trials were arranged into 5 blocks based on stimulus type: moving star field with yaw rotation, moving star field with sway translation, illusory motion with yaw, illusory motion with sway, and static arrows with sway. Static arrows were used to evaluate the effect of cognitive suggestion on self-motion perception. Each trial had a control condition; the illusory motion controls were altered versions of the experimental image, which removed the illusory motion effect. For the moving visual stimulus, controls were carried out in a dark room. With the arrow visual stimulus, controls were a gray screen. In blocks containing a visual stimulus there was an 8s viewing interval with the inertial stimulus occurring over the final 1s. This allowed measurement of the visual illusion perception using objective methods. When no visual stimulus was present, only the 1s motion stimulus was presented. Eight women and five men (mean age 37) participated. To assess for a shift in self-motion perception, the effect of each visual stimulus on the self-motion stimulus (cm/s) at which subjects were equally likely to report motion in either direction was measured. Significant effects were seen for moving star fields for both translation (p = 0.001) and rotation (pperception was shifted in the direction consistent with the visual stimulus. Arrows had a small effect on self-motion

  8. Motion control report

    CERN Document Server

    2013-01-01

    Please note this is a short discount publication. In today's manufacturing environment, Motion Control plays a major role in virtually every project.The Motion Control Report provides a comprehensive overview of the technology of Motion Control:* Design Considerations* Technologies* Methods to Control Motion* Examples of Motion Control in Systems* A Detailed Vendors List

  9. Motion sickness: a negative reinforcement model.

    Science.gov (United States)

    Bowins, Brad

    2010-01-15

    Theories pertaining to the "why" of motion sickness are in short supply relative to those detailing the "how." Considering the profoundly disturbing and dysfunctional symptoms of motion sickness, it is difficult to conceive of why this condition is so strongly biologically based in humans and most other mammalian and primate species. It is posited that motion sickness evolved as a potent negative reinforcement system designed to terminate motion involving sensory conflict or postural instability. During our evolution and that of many other species, motion of this type would have impaired evolutionary fitness via injury and/or signaling weakness and vulnerability to predators. The symptoms of motion sickness strongly motivate the individual to terminate the offending motion by early avoidance, cessation of movement, or removal of oneself from the source. The motion sickness negative reinforcement mechanism functions much like pain to strongly motivate evolutionary fitness preserving behavior. Alternative why theories focusing on the elimination of neurotoxins and the discouragement of motion programs yielding vestibular conflict suffer from several problems, foremost that neither can account for the rarity of motion sickness in infants and toddlers. The negative reinforcement model proposed here readily accounts for the absence of motion sickness in infants and toddlers, in that providing strong motivation to terminate aberrant motion does not make sense until a child is old enough to act on this motivation.

  10. Differences between clinical "snap-shot" and "real-life" assessments of lumbar spine alignment and motion - What is the "real" lumbar lordosis of a human being?

    Science.gov (United States)

    Dreischarf, Marcel; Pries, Esther; Bashkuev, Maxim; Putzier, Michael; Schmidt, Hendrik

    2016-03-21

    The individual lumbar lordosis and lumbar motion have been identified to play an important role in pathogenesis of low back pain and are essential references for preoperative planning and postoperative evaluation. The clinical "gold-standard" for measuring lumbar lordosis and its motion are radiological "snap-shots" taken while standing and during upper-body flexion and extension. The extent to which these clinically assessed values characterise lumbar alignment and its motion in daily life merits discussion. A non-invasive measurement-system was employed to measure lumbar lordosis and lumbar motion in 208 volunteers (age: 20-74yrs; ♀/♂: 115/93). For an initial short-term measurement, comparable with the clinical "snap-shot", lumbar lordosis and its motion were assessed while standing and during flexion and extension. Subsequently, volunteers were released to their daily lives while wearing the device, and measurements were performed during the following 24h. The average lumbar lordosis during 24h (8.0°) differed significantly from the standardised measurement while standing (33.3°). Ranges of motion were significantly different throughout the day compared to standing measurements. The influence of the factors age and gender on lordosis and its motion resulted in conflicting results between long- and short-term-measurements. In conclusion, results of short-term examinations differ considerably from the average values during real-life. These findings might be important for surgical planning and increase the awareness of the biomechanical challenges that spinal structures and implants face in real-life. Furthermore, long-term assessments of spinal alignment and motion during daily life can provide valid data on spinal function and can reveal the importance of influential factors. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Sensing Movement: Microsensors for Body Motion Measurement

    Directory of Open Access Journals (Sweden)

    Hansong Zeng

    2011-01-01

    Full Text Available Recognition of body posture and motion is an important physiological function that can keep the body in balance. Man-made motion sensors have also been widely applied for a broad array of biomedical applications including diagnosis of balance disorders and evaluation of energy expenditure. This paper reviews the state-of-the-art sensing components utilized for body motion measurement. The anatomy and working principles of a natural body motion sensor, the human vestibular system, are first described. Various man-made inertial sensors are then elaborated based on their distinctive sensing mechanisms. In particular, both the conventional solid-state motion sensors and the emerging non solid-state motion sensors are depicted. With their lower cost and increased intelligence, man-made motion sensors are expected to play an increasingly important role in biomedical systems for basic research as well as clinical diagnostics.

  12. Free radial forearm flap versatility for the head and neck and lower extremity

    International Nuclear Information System (INIS)

    Chicarilli, Z.N.; Ariyan, S.; Cuono, C.B.

    1986-01-01

    Microsurgical techniques have developed numerous territories suitable for free tissue transfer. However, the demand for thin cutaneous resurfacing limits the choice of flaps available to the reconstructive microsurgeon. The radial forearm flap is a thin, axial, fasciocutaneous flap, offering pliable cutaneous resurfacing, with or without sensation. We have used 15 flaps to reconstruct defects in the head and neck and lower extremity resulting from burns, blunt and avulsive trauma, radiation necrosis, and tumor ablation. Two flaps (15 percent) developed venous congestion and were salvaged by reoperation. One retrograde flap (7.5 percent) developed partial necrosis from arterial insufficiency. Neural re-innervation was successful in two out of three patients in whom it was attempted. Two patients (15%) sustained minor donor site skin graft loss that healed secondarily. In our series of predominantly older patients the donor sites have been relatively inconspicuous at one year follow-up. A functional restoration was achieved in all patients

  13. Implementation of mathematical phantom of hand and forearm in GEANT4 Monte Carlo code

    International Nuclear Information System (INIS)

    Pessanha, Paula Rocha; Queiroz Filho, Pedro Pacheco de; Santos, Denison de Souza

    2014-01-01

    In this work, the implementation of a hand and forearm Geant4 phantom code, for further evaluation of occupational exposure of ends of the radionuclides decay manipulated during procedures involving the use of injection syringe. The simulation model offered by Geant4 includes a full set of features, with the reconstruction of trajectories, geometries and physical models. For this work, the values calculated in the simulation are compared with the measurements rates by thermoluminescent dosimeters (TLDs) in physical phantom REMAB®. From the analysis of the data obtained through simulation and experimentation, of the 14 points studied, there was a discrepancy of only 8.2% of kerma values found, and these figures are considered compatible. The geometric phantom implemented in Geant4 Monte Carlo code was validated and can be used later for the evaluation of doses at ends

  14. Does a distal forearm fracture lead to evaluation for osteoporosis? A retrospective cohort study in 147 Danish women

    DEFF Research Database (Denmark)

    Rud, Bo; Greibe, Rasmus; Hyldstrup, Lars

    2005-01-01

    In postmenopausal women, a low-trauma distal forearm fracture is a risk factor for osteoporosis and future fracture, which indicates osteoporosis follow-up according to prevailing guidelines. We decided to determine how often women over 45 yr presenting with a low-trauma distal forearm fracture t......, and it emphasizes the need to decide on a local level how to provide osteoporosis follow-up for women with fragility fractures. Udgivelsesdato: 2005 Spring......In postmenopausal women, a low-trauma distal forearm fracture is a risk factor for osteoporosis and future fracture, which indicates osteoporosis follow-up according to prevailing guidelines. We decided to determine how often women over 45 yr presenting with a low-trauma distal forearm fracture...... to a Danish emergency department during a 1-yr period were followed up for osteoporosis. We performed a retrospective review of hospital records and we sent the women and their general practitioners (GPs) questionnaires regarding the follow-up undertaken in primary care. Finally, we invited the women...

  15. Odds ratios for hip- and lower forearm fracture using peripheral bone densitometry; a case-control study of postmenopausal women

    DEFF Research Database (Denmark)

    Saleh, M M A; Jørgensen, H L; Lauritzen, J B

    2002-01-01

    concern when using peripheral densitometry is the poor correlation with the central measurements. The main aim of this study is, therefore, to assess the possibility of expressing ultrasound measurements at the heel and bone mineral density (BMD) measured at the distal forearm as fracture odds ratios...... rather than an absolute measure of bone mass. METHODS: A total of 76 women with lower forearm fracture, 47 women with hip fracture and 231 age-matched women (controls) were included. All had broadband ultrasound attenuation (BUA) and speed of sound (SOS) measured at the heel using the DTU-one ultrasound.......8; 5.2) for heel-BUA (T-score cutoff: -2.3), 4.1 (2.3; 7.4) for heel-SOS (-2.1) and 2.2 (1.3; 3.7) for lower forearm BMD (-2.7). The odds ratio for hip fracture was 3.4 (1.5-7.7) for heel-BUA (-2.7), 3.6 (1.6; 8.1) for heel-SOS (-2.6) and 3.2 (1.4; 7.4) for lower forearm BMD (-2.9). CONCLUSION...

  16. Maternal Dietary Patterns during Pregnancy in Relation to Offspring Forearm Fractures: Prospective Study from the Danish National Birth Cohort

    Directory of Open Access Journals (Sweden)

    Sesilje B. Petersen

    2015-04-01

    Full Text Available Limited evidence exists for an association between maternal diet during pregnancy and offspring bone health. In a prospective study, we examined the association between dietary patterns in mid-pregnancy and offspring forearm fractures. In total, 101,042 pregnancies were recruited to the Danish National Birth Cohort (DNBC during 1996–2002. Maternal diet was collected by a food frequency questionnaire. Associations were analyzed between seven dietary patterns extracted by principal component analysis and offspring first occurrence of any forearm fracture diagnosis, extracted from the Danish National Patient Register, between time of birth and end of follow-up (<16 year (n = 53,922. In multivariable Cox regression models, offspring of mothers in the fourth vs. first quintile of the Western pattern had a significant increased risk (Hazard ratio, 95% confidence interval: 1.11, 1.01–1.23 of fractures, and there was a borderline significant positive trend (p = 0.06. The other dietary patterns showed no associations and neither did supplementary analyses of macro- and micronutrients or single food groups, except for the intake of artificially sweetened soft drinks, which was positively associated with offspring forearm fractures (p = 0.02. In the large prospective DNBC high mid-pregnancy consumption of Western diet and artificially sweetened soft drinks, respectively, indicated positive associations with offspring forearm fractures, which provides interesting hypotheses for future research.

  17. Treatment of Wound Healing Disorders of Radial Forearm Free Flap Donor Sites Using Cold Atmospheric Plasma: A Proof of Concept.

    Science.gov (United States)

    Hartwig, Stefan; Doll, Christian; Voss, Jan Oliver; Hertel, Moritz; Preissner, Saskia; Raguse, Jan Dirk

    2017-02-01

    The treatment of wound healing disturbances of the radial forearm free flap donor site after reconstructive surgery is typically long and burdensome and often requires additional surgery. Cold atmospheric plasma is a promising approach to overcome these impairments. The aim of this proof of concept study was to evaluate the clinical outcome of plasma irradiation in patients with wound healing disorders with exposed brachial tendons of the radial forearm. Four patients (mean age 64.2 years, range 44 to 80) who had undergone radial forearm free flap procedures and developed wound healing disturbance leading to exposed flexor tendons were included in the present prospective case series. In addition to routine wound care, all sites were irradiated with cold atmospheric plasma. The primary outcome variable was complete wound closure. In all patients, complete wound repair in terms of the absence of tendon exposure was observed within a mean treatment time of 10.1 weeks (range 4.9 to 16). No undesirable side effects were observed, and no inflammation or infection occurred. Cold atmospheric plasma could offer a reliable conservative treatment option for complicated wound healing disturbances. This was exemplarily shown in the case of radial forearm free flap donor site morbidity with exposed flexor tendons in the present study. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  18. The effect of a forearm/hand splint compared with an elbow band as a treatment for lateral epicondylitis

    NARCIS (Netherlands)

    van de Streek, M.D.; van der Schans, C.P.; de Greef, M.H.G.; Postema, K.

    2004-01-01

    The aim of the present study was to compare the effect of a new prefabricated Thamert forearm/hand splint with the effect of a simple elbow band as a treatment for lateral epicondylitis. Forty-three (43) patients that met the inclusion criteria were randomly assigned to the elbow band group and the

  19. Blood flow and muscle oxygen uptake at the onset and end of moderate and heavy dynamic forearm exercise.

    NARCIS (Netherlands)

    Beekvelt, M.C.P. van; Shoemaker, J.K.; Tschakovsky, M.E.; Hopman, M.T.E.; Hughson, R.L.

    2001-01-01

    We hypothesized that forearm blood flow (FBF) during moderate intensity dynamic exercise would meet the demands of the exercise and that postexercise FBF would quickly recover. In contrast, during heavy exercise, FBF would be inadequate causing a marked postexercise hyperemia and sustained increase

  20. The interactive effect of cooling and hypoxia on forearm fatigue development.

    Science.gov (United States)

    Lloyd, Alex; Hodder, Simon; Havenith, George

    2015-09-01

    To examine the effect of separate and combined exposure to hypoxia [normoxia (FIO2 = 0.21) vs. moderate altitude (FIO2 = 0.13)] and temperature [thermoneutral (22 °C) vs. cold (5 °C)] on muscle fatigue development in the forearm, after repeated low-resistance contractions. Eight males were exposed for 70 min to four separate conditions in a balanced order. Conditions were normoxic-thermoneutral (N), hypoxic-thermoneutral, normoxic-cold and hypoxic-cold. After 15-min seated rest, participants carried out intermittent dynamic forearm exercise at 15 % maximal isometric voluntary contraction (MVC) for eight consecutive, 5-min work bouts. Each bout was separated by 110 s rest during which MVC force was collected. When exposed to hypoxia and cold independently, the exercise protocol decreased MVC force of the finger flexors by 8.1 and 13.9 %, respectively, compared to thermoneutral normoxia. When hypoxia and cold were combined, the decrease in MVC force was 21.4 % more than thermoneutral normoxia, reflecting an additive effect and no interaction. EMG relative to force produced during MVC, increased by 2 and 1.2 μV per kg (36 and 23 % of N) for cold and hypoxia, respectively. When the stressors were combined the effect was additive, increasing to 3.1 μV per kg (56 % of N). When compared to exercise in thermoneutral normoxic conditions, both cold and hypoxia significantly reduce brief MVC force output. This effect appears to be of mechanical origin, not a failure in muscle fibre recruitment per se. Additionally, the reduction in force is greater when the stressors are combined, showing an additive effect.