WorldWideScience

Sample records for human eye length

  1. Intraoperative length and tension curves of human eye muscles. Including stiffness in passive horizontal eye movement in awake volunteers

    NARCIS (Netherlands)

    H.J. Simonsz (Huib); G.H. Kolling (Gerold); H. Kaufmann (Herbert); B. van Dijk (Bob)

    1986-01-01

    textabstractIntraoperative continuous-registration length and tension curves of attached and detached eye muscles were made in 18 strabismic patients under general anesthesia. For relaxed eye muscles, we found an exponential relation between length and tension. An increased stiffness was quantified

  2. Automatic measurement of axial length of human eye using three-dimensional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Watanabe, Masaki; Kiryu, Tohru

    2011-01-01

    The measurement of axial length and the evaluation of three dimensional (3D) form of an eye are essential to evaluate the mechanism of myopia progression. We propose a method of automatic measurement of axial length including adjustment of the pulse sequence of short-term scan which could suppress influence of eyeblink, using a magnetic resonance imaging (MRI) which acquires 3D images noninvasively. Acquiring T 2 -weighted images with 3.0 tesla MRI device and eight-channel phased-array head coil, we extracted left and right eye ball images, and then reconstructed 3D volume. The surface coordinates were calculated from 3D volume, fitting the ellipsoid model coordinates with the surface coordinates, and measured the axial length automatically. Measuring twenty one subjects, we compared the automatically measured values of axial length with the manually measured ones, then confirmed significant elongation in the axial length of myopia compared with that of emmetropia. Furthermore, there were no significant differences (P<0.05) between the means of automatic measurements and the manual ones. Accordingly, the automatic measurement process of axial length could be a tool for the elucidation of the mechanism of myopia progression, which would be suitable for evaluating the axial length easily and noninvasively. (author)

  3. Arthropods affecting the human eye.

    Science.gov (United States)

    Panadero-Fontán, Rosario; Otranto, Domenico

    2015-02-28

    Ocular infestations by arthropods consist in the parasitization of the human eye, either directly (e.g., some insect larvae causing ophthalmomyiasis) or via arthropods feeding on lachrymal/conjunctival secretions (e.g., some eye-seeking insects, which also act as vectors of eye pathogens). In addition, demodicosis and phthiriasis may also cause eye discomfort in humans. Ophthalmomyiasis by larvae of the families Oestridae, Calliphoridae and Sarcophagidae, are frequent causative agents of human ocular infestations. Over the last decades, the extensive use of macrocyclic lactones in cattle has reduced the frequency of infestations by Hypoderma bovis and Hypoderma lineatum (family Oestridae), and consequently, human infestations by these species. A prompt diagnosis of ocular myiasis (e.g., by serological tests) is pivotal for positive prognoses, particularly when the larvae are not detectable during the ophthalmologic examination. Molecular diagnoses may also assist physicians and parasitologists in achieving time-efficient diagnoses of infestations by Oestridae causing myiasis. Finally, due to widespread international travel to exotic destinations, cases of myiasis are increasing in non-endemic areas, therefore requiring physicians to acquire a profound knowledge of the clinical symptoms linked to these infestations to prevent costly, inappropriate treatments or severe complications. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. A Model of the Human Eye

    Science.gov (United States)

    Colicchia, G.; Wiesner, H.; Waltner, C.; Zollman, D.

    2008-01-01

    We describe a model of the human eye that incorporates a variable converging lens. The model can be easily constructed by students with low-cost materials. It shows in a comprehensible way the functionality of the eye's optical system. Images of near and far objects can be focused. Also, the defects of near and farsighted eyes can be demonstrated.

  5. Modelling human eye under blast loading.

    Science.gov (United States)

    Esposito, L; Clemente, C; Bonora, N; Rossi, T

    2015-01-01

    Primary blast injury (PBI) is the general term that refers to injuries resulting from the mere interaction of a blast wave with the body. Although few instances of primary ocular blast injury, without a concomitant secondary blast injury from debris, are documented, some experimental studies demonstrate its occurrence. In order to investigate PBI to the eye, a finite element model of the human eye using simple constitutive models was developed. The material parameters were calibrated by a multi-objective optimisation performed on available eye impact test data. The behaviour of the human eye and the dynamics of mechanisms occurring under PBI loading conditions were modelled. For the generation of the blast waves, different combinations of explosive (trinitrotoluene) mass charge and distance from the eye were analysed. An interpretation of the resulting pressure, based on the propagation and reflection of the waves inside the eye bulb and orbit, is proposed. The peculiar geometry of the bony orbit (similar to a frustum cone) can induce a resonance cavity effect and generate a pressure standing wave potentially hurtful for eye tissues.

  6. Optical models of the human eye.

    Science.gov (United States)

    Atchison, David A; Thibos, Larry N

    2016-03-01

    Optical models of the human eye have been used in visual science for purposes such as providing a framework for explaining optical phenomena in vision, for predicting how refraction and aberrations are affected by change in ocular biometry and as computational tools for exploring the limitations imposed on vision by the optical system of the eye. We address the issue of what is understood by optical model eyes, discussing the 'encyclopaedia' and 'toy train' approaches to modelling. An extensive list of purposes of models is provided. We discuss many of the theoretical types of optical models (also schematic eyes) of varying anatomical accuracy, including single, three and four refracting surface variants. We cover the models with lens structure in the form of nested shells and gradient index. Many optical eye models give accurate predictions only for small angles and small fields of view. If aberrations and image quality are important to consider, such 'paraxial' model eyes must be replaced by 'finite model' eyes incorporating features such as aspheric surfaces, tilts and decentrations, wavelength-dependent media and curved retinas. Many optical model eyes are population averages and must become adaptable to account for age, gender, ethnicity, refractive error and accommodation. They can also be customised for the individual when extensive ocular biometry and optical performance data are available. We consider which optical model should be used for a particular purpose, adhering to the principle that the best model is the simplest fit for the task. We provide a glimpse into the future of optical models of the human eye. This review is interwoven with historical developments, highlighting the important people who have contributed so richly to our understanding of visual optics. © 2016 The Authors. Clinical and Experimental Optometry © 2016 Optometry Australia.

  7. Prediction of Human Eye Fixations using Symmetry

    OpenAIRE

    Kootstra, Gert; Schomaker, Lambert R. B.

    2009-01-01

    Humans are very sensitive to symmetry in visual patterns. Reaction time experiments show that symmetry is detected and recognized very rapidly. This suggests that symmetry is a highly salient feature. Existing computational models of saliency, however, have mainly focused on contrast as a measure of saliency. In this paper, we discuss local symmetry as a measure of saliency. We propose a number of symmetry models and perform an eye-tracking study with human participants viewing photographic i...

  8. Simulation of airbag impact on eyes with different axial lengths after transsclerally fixated posterior chamber intraocular lens by using finite element analysis

    Directory of Open Access Journals (Sweden)

    Huang J

    2015-02-01

    Full Text Available Jane Huang,1 Eiichi Uchio,1 Satoru Goto2 1Department of Ophthalmology, Fukuoka University School of Medicine, Fukuoka, 2Nihon ESI KK Technical Division, Tokyo, Japan Purpose: To determine the biomechanical response of an impacting airbag on eyes with different axial lengths with transsclerally fixated posterior chamber intraocular lens (PC IOL.Materials and methods: Simulations in a model human eye were performed with a computer using a finite element analysis program created by Nihon, ESI Group. The airbag was set to be deployed at five different velocities and to impact on eyes with three different axial lengths. These eyes were set to have transsclerally fixated PC IOL by a 10-0 polypropylene possessing a tensile force limit of 0.16 N according to the United States Pharmacopeia XXII.Results: The corneoscleral opening was observed at a speed of 40 m/second or more in all model eyes. Eyes with the longest axial length of 25.85 mm had the greatest extent of deformity at any given impact velocity. The impact force exceeded the tensile force of 10-0 polypropylene at an impact velocity of 60 m/second in all eyes, causing breakage of the suture. Conclusion: Eyes with transsclerally fixated PC IOL could rupture from airbag impact at high velocities. Eyes with long axial lengths experienced a greater deformity upon airbag impact due to a thinner eye wall. Further basic research on the biomechanical response for assessing eye injuries could help in developing a better airbag and in the further understanding of ocular traumas. Keywords: airbag, ocular trauma, computer simulation, transsclerally fixated posterior chamber intraocular lens, finite element analysis

  9. Communication Aid with Human Eyes Only

    Science.gov (United States)

    Arai, Kohei; Yajima, Kenro

    A communication aid with human eyes only is proposed. A set of candidate character is displayed onto computer screen of relatively small and light Head Mount Display: HMD that is mounted on glasses of which user wears on. When user looks at a candidate character with his/hers left eye while right eye picture is taken with small and light web camera that also is mounted on the glasses. The proposed system can selects 81 characters with two layers of 9 by 9 character candidate image. Other than these there is another selective image including control keys and frequently use of sentences. By using image matching between previously acquired template image for each candidate character and the currently acquired image, the proposed system realizes that which character in the candidates is selected. By using blinking and fix one's eye on combine together, the proposed system recognizes that user determines the selected key from the candidates. The blinking detection method employs a morphologic filter to avoid misunderstanding of dark eye detection due to eyebrows and shadows. Thus user can input sentences. User also may edit the sentences and then the sentences are read with Text to Speech: TTS software tool. Thus the system allows support conversations between handicapped and disabled persons without voice and the others peoples because only the function required for conversation is human eyes. Also the proposed system can be used as an input system for wearable computing systems. Test results by the 6 different able persons show that the proposed system does work with acceptable speed, around 1.5 second / character.

  10. Molecular restrictions for human eye irritation by chemical vapors

    International Nuclear Information System (INIS)

    Cometto-Muniz, J. Enrique; Cain, William S.; Abraham, Michael H.

    2005-01-01

    Previous research showed a cut-off along homologous volatile organic compounds (VOCs) in their ability to produce acute human mucosal irritation. The present study sought to specify the particular cut-off homolog for sensory eye irritation in an acetate and n-alcohol series. A 1900-ml glass vessel system and a three-alternative forced-choice procedure served to test nonyl, decyl, and dodecyl acetate, and 1-nonanol, 1-decanol, and 1-undecanol. Flowrate to the eye ranged from 2 to 8 L/min and time of exposure from 3 to 24 s. Decyl acetate and 1-undecanol were the shortest homologs that failed to produce eye irritation under all conditions, producing a cut-off effect. Increasing the vapor concentration of decyl acetate and 1-undecanol by 3 and 8 times, respectively, via heating them to 37 deg C made either or both VOCs detectable to only half of the 12 subjects tested, even though the higher vapor concentration was well above a predicted eye irritation threshold. When eye irritation thresholds for homologous acetates and n-alcohols were plotted as a function of the longest unfolded length of the molecule, the values for decyl acetate and 1-undecanol fell within a restricted range of 18 to 19 A. The outcome suggests that the basis for the cut-off is biological, that is, the molecule lacks a key size or structure to trigger transduction, rather than physical, that is, the vapor concentration is too low to precipitate detection

  11. Zoonotic helminths affecting the human eye

    Science.gov (United States)

    2011-01-01

    Nowaday, zoonoses are an important cause of human parasitic diseases worldwide and a major threat to the socio-economic development, mainly in developing countries. Importantly, zoonotic helminths that affect human eyes (HIE) may cause blindness with severe socio-economic consequences to human communities. These infections include nematodes, cestodes and trematodes, which may be transmitted by vectors (dirofilariasis, onchocerciasis, thelaziasis), food consumption (sparganosis, trichinellosis) and those acquired indirectly from the environment (ascariasis, echinococcosis, fascioliasis). Adult and/or larval stages of HIE may localize into human ocular tissues externally (i.e., lachrymal glands, eyelids, conjunctival sacs) or into the ocular globe (i.e., intravitreous retina, anterior and or posterior chamber) causing symptoms due to the parasitic localization in the eyes or to the immune reaction they elicit in the host. Unfortunately, data on HIE are scant and mostly limited to case reports from different countries. The biology and epidemiology of the most frequently reported HIE are discussed as well as clinical description of the diseases, diagnostic considerations and video clips on their presentation and surgical treatment. Homines amplius oculis, quam auribus credunt Seneca Ep 6,5 Men believe their eyes more than their ears PMID:21429191

  12. Zoonotic helminths affecting the human eye

    Directory of Open Access Journals (Sweden)

    Eberhard Mark L

    2011-03-01

    Full Text Available Abstract Nowaday, zoonoses are an important cause of human parasitic diseases worldwide and a major threat to the socio-economic development, mainly in developing countries. Importantly, zoonotic helminths that affect human eyes (HIE may cause blindness with severe socio-economic consequences to human communities. These infections include nematodes, cestodes and trematodes, which may be transmitted by vectors (dirofilariasis, onchocerciasis, thelaziasis, food consumption (sparganosis, trichinellosis and those acquired indirectly from the environment (ascariasis, echinococcosis, fascioliasis. Adult and/or larval stages of HIE may localize into human ocular tissues externally (i.e., lachrymal glands, eyelids, conjunctival sacs or into the ocular globe (i.e., intravitreous retina, anterior and or posterior chamber causing symptoms due to the parasitic localization in the eyes or to the immune reaction they elicit in the host. Unfortunately, data on HIE are scant and mostly limited to case reports from different countries. The biology and epidemiology of the most frequently reported HIE are discussed as well as clinical description of the diseases, diagnostic considerations and video clips on their presentation and surgical treatment. Homines amplius oculis, quam auribus credunt Seneca Ep 6,5 Men believe their eyes more than their ears

  13. Theoretical investigation of aberrations upon ametropic human eyes

    Science.gov (United States)

    Tan, Bo; Chen, Ying-Ling; Lewis, J. W. L.; Baker, Kevin

    2003-11-01

    The human eye aberrations are important for visual acuity and ophthalmic diagnostics and surgical procedures. Reported monochromatic aberration data of the normal 20/20 human eyes are scarce. There exist even fewer reports of the relation between ametropic conditions and aberrations. We theoretically investigate the monochromatic and chromatic aberrations of human eyes for refractive errors of -10 to +10 diopters. Schematic human eye models are employed using optical design software for axial, index, and refractive types of ametropia.

  14. Higher order monochromatic aberrations of the human infant eye

    OpenAIRE

    Wang, Jingyun; Candy, T. Rowan

    2005-01-01

    The monochromatic optical aberrations of the eye degrade retinal image quality. Any significant aberrations during postnatal development could contribute to infants’ immature visual performance and provide signals for the control of eye growth. Aberrations of human infant eyes from 5 to 7 weeks old were compared with those of adult subjects using a model of an adultlike infant eye that accounted for differences in both eye and pupil size. Data were collected using the COAS Shack-Hartmann wave...

  15. The Effect of Gestational Age on Axial Length of the Eyes of Premature Infants

    Directory of Open Access Journals (Sweden)

    Mehmet Ali Sekeroglu

    2016-01-01

    Full Text Available Aim: The aim of the present study is to evaluate the axial length of the eyes of premature infants without retinopathy of prematurity and to document the relationship with gestational age and changes as infants grew-up. Material and Method: The axial length of the eyes were measured by using a mobile A-scan ultrasonographic biometry device just before the first retinopathy of prematurity screening examination and 4-weeks thereafter. Results: One-hundred and thirty-six infants with a mean gestational age of 31,7±2,7 weeks and a birth-weight of 1561.0±379.3 g were included in the study. Axial length measurements were done at a mean postconceptional age of 35.8 ±2.6 (31-40 and 39.8±2.7 (35-44 weeks, consecutively. The mean axial length at first and second visits were 16.43±0.42 mm (15.28-17.13 and 16.69±0.41 mm (15.60-17.70, consecutively (p

  16. Cyclooxygenase-2 expression in the normal human eye and its expression pattern in selected eye tumours

    DEFF Research Database (Denmark)

    Wang, Jinmei; Wu, Yazhen; Heegaard, Steffen

    2011-01-01

    Purpose: Cyclooxygenase-2 (COX-2) is an enzyme involved in neoplastic processes. The purpose of the present study is to investigate COX-2 expression in the normal human eye and the expression pattern in selected eye tumours involving COX-2 expressing cells. Methods: Immunohistochemical staining...... using antibodies against COX-2 was performed on paraffin sections of normal human eyes and selected eye tumours arising from cells expressing COX-2. Results: Cyclooxygenase-2 expression was found in various structures of the normal eye. Abundant expression was seen in the cornea, iris, ciliary body...... and retina. The COX-2 expression was less in tumours deriving from the ciliary epithelium and also in retinoblastoma. Conclusion: Cyclooxygenase-2 is constitutively expressed in normal human eyes. The expression of COX-2 is much lower in selected eye tumours involving COX-2 expressing cells....

  17. Virtual pharmacokinetic model of human eye.

    Science.gov (United States)

    Kotha, Sreevani; Murtomäki, Lasse

    2014-07-01

    A virtual pharmacokinetic 3D model of the human eye is built using Comsol Multiphysics® software, which is based on the Finite Element Method (FEM). The model considers drug release from a polymer patch placed on sclera. The model concentrates on the posterior part of the eye, retina being the target tissue, and comprises the choroidal blood flow, partitioning of the drug between different tissues and active transport at the retina pigment epithelium (RPE)-choroid boundary. Although most straightforward, in order to check the mass balance, no protein binding or metabolism is yet included. It appeared that the most important issue in obtaining reliable simulation results is the finite element mesh, while time stepping has hardly any significance. Simulations were extended to 100,000 s. The concentration of a drug is shown as a function of time at various points of retina, as well as its average value, varying several parameters in the model. This work demonstrates how anybody with basic knowledge of calculus is able to build physically meaningful models of quite complex biological systems. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Correlations between psychometric schizotypy, scan path length, fixations on the eyes and face recognition.

    Science.gov (United States)

    Hills, Peter J; Eaton, Elizabeth; Pake, J Michael

    2016-01-01

    Psychometric schizotypy in the general population correlates negatively with face recognition accuracy, potentially due to deficits in inhibition, social withdrawal, or eye-movement abnormalities. We report an eye-tracking face recognition study in which participants were required to match one of two faces (target and distractor) to a cue face presented immediately before. All faces could be presented with or without paraphernalia (e.g., hats, glasses, facial hair). Results showed that paraphernalia distracted participants, and that the most distracting condition was when the cue and the distractor face had paraphernalia but the target face did not, while there was no correlation between distractibility and participants' scores on the Schizotypal Personality Questionnaire (SPQ). Schizotypy was negatively correlated with proportion of time fixating on the eyes and positively correlated with not fixating on a feature. It was negatively correlated with scan path length and this variable correlated with face recognition accuracy. These results are interpreted as schizotypal traits being associated with a restricted scan path leading to face recognition deficits.

  19. Aquaporins 6-12 in the human eye

    DEFF Research Database (Denmark)

    Tran, Thuy Linh; Bek, Toke; Holm, Lars

    2012-01-01

    Purpose: Aquaporins (AQPs) are widely expressed and have diverse distribution patterns in the eye. AQPs 0-5 have been localized at the cellular level in human eyes. We investigated the presence of the more recently discovered AQPs 6-12 in the human eye. Methods: RT-PCR was performed on fresh tissue...... from two human eyes divided into the cornea, corneal limbus, ciliary body and iris, lens, choroid, optic nerve, retina and sclera. Each structure was examined to detect the mRNA of AQPs 6-12. Twenty-one human eyes were examined using immunohistochemical and immunofluorescence techniques to determine...... was detected in the corneal epithelium, corneal endothelium, trabecular meshwork endothelium, ciliary epithelia, lens epithelium, the inner and outer limiting membrane of the retina, the retinal pigment epithelium and the capillary endothelium of all parts of the eye. AQP9 immunolabelling was detected...

  20. A scalable and deformable stylized model of the adult human eye for radiation dose assessment.

    Science.gov (United States)

    El Basha, Daniel; Furuta, Takuya; Iyer, Siva S R; Bolch, Wesley E

    2018-03-23

    With recent changes in the recommended annual limit on eye lens exposures to ionizing radiation, there is considerable interest in predictive computational dosimetry models of the human eye and its various ocular structures including the crystalline lens, ciliary body, cornea, retina, optic nerve, and central retinal artery. Computational eye models to date have been constructed as stylized models, high-resolution voxel models, and polygon mesh models. Their common feature, however, is that they are typically constructed of nominal size and of a roughly spherical shape associated with the emmetropic eye. In this study, we present a geometric eye model that is both scalable (allowing for changes in eye size) and deformable (allowing for changes in eye shape), and that is suitable for use in radiation transport studies of ocular exposures and radiation treatments of eye disease. The model allows continuous and variable changes in eye size (axial lengths from 20 to 26 mm) and eye shape (diopters from -12 to +6). As an explanatory example of its use, five models (emmetropic eyes of small, average, and large size, as well as average size eyes of -12D and +6D) were constructed and subjected to normally incident beams of monoenergetic electrons and photons, with resultant energy-dependent dose coefficients presented for both anterior and posterior eye structures. Electron dose coefficients were found to vary with changes to both eye size and shape for the posterior eye structures, while their values for the eye crystalline lens were found to be sensitive to changes in only eye size. No dependence upon eye size or eye shape was found for photon dose coefficients at energies below 2 MeV. Future applications of the model can include more extensive tabulations of dose coefficients to all ocular structures (not only the lens) as a function of eye size and shape, as well as the assessment of x-ray therapies for ocular disease for patients with non-emmetropic eyes. © 2018

  1. Determination of positions of optical elements of the human eye

    International Nuclear Information System (INIS)

    Galetskii, S O; Cherezova, T Yu

    2009-01-01

    An original method for noninvasive determining the positions of elements of intraocular optics is proposed. The analytic dependence of the measurement error on the optical-scheme parameters and the restriction in distance from the element being measured are determined within the framework of the method proposed. It is shown that the method can be efficiently used for determining the position of elements in the classical Gullstrand eye model and personalised eye models. The positions of six optical surfaces of the Gullstrand eye model and four optical surfaces of the personalised eye model can be determined with an error of less than 0.25 mm. (human eye optics)

  2. A scalable and deformable stylized model of the adult human eye for radiation dose assessment

    Science.gov (United States)

    El Basha, Daniel; Furuta, Takuya; Iyer, Siva S. R.; Bolch, Wesley E.

    2018-05-01

    With recent changes in the recommended annual limit on eye lens exposures to ionizing radiation, there is considerable interest in predictive computational dosimetry models of the human eye and its various ocular structures including the crystalline lens, ciliary body, cornea, retina, optic nerve, and central retinal artery. Computational eye models to date have been constructed as stylized models, high-resolution voxel models, and polygon mesh models. Their common feature, however, is that they are typically constructed of nominal size and of a roughly spherical shape associated with the emmetropic eye. In this study, we present a geometric eye model that is both scalable (allowing for changes in eye size) and deformable (allowing for changes in eye shape), and that is suitable for use in radiation transport studies of ocular exposures and radiation treatments of eye disease. The model allows continuous and variable changes in eye size (axial lengths from 20 to 26 mm) and eye shape (diopters from  ‑12 to  +6). As an explanatory example of its use, five models (emmetropic eyes of small, average, and large size, as well as average size eyes of  ‑12D and  +6D) were constructed and subjected to normally incident beams of monoenergetic electrons and photons, with resultant energy-dependent dose coefficients presented for both anterior and posterior eye structures. Electron dose coefficients were found to vary with changes to both eye size and shape for the posterior eye structures, while their values for the crystalline lens were found to be sensitive to changes in only eye size. No dependence upon eye size or eye shape was found for photon dose coefficients at energies below 2 MeV. Future applications of the model can include more extensive tabulations of dose coefficients to all ocular structures (not only the lens) as a function of eye size and shape, as well as the assessment of x-ray therapies for ocular disease for patients with non

  3. Gamma crystallins of the human eye lens.

    Science.gov (United States)

    Vendra, Venkata Pulla Rao; Khan, Ismail; Chandani, Sushil; Muniyandi, Anbukkarasi; Balasubramanian, Dorairajan

    2016-01-01

    Protein crystallins co me in three types (α, β and γ) and are found predominantly in the eye, and particularly in the lens, where they are packed into a compact, plastic, elastic, and transparent globule of proper refractive power range that aids in focusing incoming light on to the retina. Of these, the γ-crystallins are found largely in the nuclear region of the lens at very high concentrations (>400 mg/ml). The connection between their structure and inter-molecular interactions and lens transparency is an issue of particular interest. We review the origin and phylogeny of the gamma crystallins, their special structure involving the use of Greek key supersecondary structural motif, and how they aid in offering the appropriate refractive index gradient, intermolecular short range attractive interactions (aiding in packing them into a transparent ball), the role that several of the constituent amino acid residues play in this process, the thermodynamic and kinetic stability and how even single point mutations can upset this delicate balance and lead to intermolecular aggregation, forming light-scattering particles which compromise transparency. We cite several examples of this, and illustrate this by cloning, expressing, isolating and comparing the properties of the mutant protein S39C of human γS-crystallin (associated with congenital cataract-microcornea), with those of the wild type molecule. In addition, we note that human γ-crystallins are also present in other parts of the eye (e.g., retina), where their functions are yet to be understood. There are several 'crucial' residues in and around the Greek key motifs which are essential to maintain the compact architecture of the crystallin molecules. We find that a mutation that replaces even one of these residues can lead to reduction in solubility, formation of light-scattering particles and loss of transparency in the molecular assembly. Such a molecular understanding of the process helps us construct the

  4. A novel algorithm for automatic localization of human eyes

    Institute of Scientific and Technical Information of China (English)

    Liang Tao (陶亮); Juanjuan Gu (顾涓涓); Zhenquan Zhuang (庄镇泉)

    2003-01-01

    Based on geometrical facial features and image segmentation, we present a novel algorithm for automatic localization of human eyes in grayscale or color still images with complex background. Firstly, a determination criterion of eye location is established by the prior knowledge of geometrical facial features. Secondly,a range of threshold values that would separate eye blocks from others in a segmented face image (I.e.,a binary image) are estimated. Thirdly, with the progressive increase of the threshold by an appropriate step in that range, once two eye blocks appear from the segmented image, they will be detected by the determination criterion of eye location. Finally, the 2D correlation coefficient is used as a symmetry similarity measure to check the factuality of the two detected eyes. To avoid the background interference, skin color segmentation can be applied in order to enhance the accuracy of eye detection. The experimental results demonstrate the high efficiency of the algorithm and correct localization rate.

  5. Indentation and needle insertion properties of the human eye.

    Science.gov (United States)

    Matthews, A; Hutnik, C; Hill, K; Newson, T; Chan, T; Campbell, G

    2014-07-01

    Characterization of the biomechanical properties of the human eye has a number of potential utilities. One novel purpose is to provide the basis for development of suitable tissue-mimicking material. The purpose of this study was to determine the indentation and needle insertion characteristics on human eye globes and tissue strips. An indenter assessed the elastic response of human eye globes and tissue strips under increasing compressive loads. Needle insertion determined the force (N) needed to penetrate various areas of the eye wall. The results demonstrated that globes underwent slightly greater indentation at the midline than at the central cornea, and corneal strips indented twofold more than scleral strips, although neither difference was significant (P=0.400 and P=0.100, respectively). Significant differences were observed among various areas of needle insertion (Phuman eye construct with potential utility as a model for use in ophthalmology research and surgical teaching.

  6. Human eye and the sun hot and cold light

    CERN Document Server

    Vavilov, S I

    1965-01-01

    The Human Eye and the Sun, """"Hot"""" and """"Cold"""" Light is a translation from the Russian language and is a reproduction of texts from Volume IV of S.I. Vavilov, president of the U.S.S.R. Academy of Sciences. The book deals with theoretical and practical developments in lighting techniques. The text gives a brief introduction on the relationship of the human eye and the sun, describing the properties of light, of the sun, and of the human eye. The book describes hot (incandescence) and cold light (luminescence) as coming from different sources. These two types of light are compared. The

  7. The processing of spatial information in short-term memory: insights from eye tracking the path length effect.

    Science.gov (United States)

    Guérard, Katherine; Tremblay, Sébastien; Saint-Aubin, Jean

    2009-10-01

    Serial memory for spatial locations increases as the distance between successive stimuli locations decreases. This effect, known as the path length effect [Parmentier, F. B. R., Elford, G., & Maybery, M. T. (2005). Transitional information in spatial serial memory: Path characteristics affect recall performance. Journal of Experimental Psychology: Learning, Memory & Cognition, 31, 412-427], was investigated in a systematic manner using eye tracking and interference procedures to explore the mechanisms responsible for the processing of spatial information. In Experiment 1, eye movements were monitored during a spatial serial recall task--in which the participants have to remember the location of spatially and temporally separated dots on the screen. In the experimental conditions, eye movements were suppressed by requiring participants to incessantly move their eyes between irrelevant locations. Ocular suppression abolished the path length effect whether eye movements were prevented during item presentation or during a 7s retention interval. In Experiment 2, articulatory suppression was combined with a spatial serial recall task. Although articulatory suppression impaired performance, it did not alter the path length effect. Our results suggest that rehearsal plays a key role in serial memory for spatial information, though the effect of path length seems to involve other processes located at encoding, such as the time spent fixating each location and perceptual organization.

  8. Human eye localization using the modified Hough transform

    Czech Academy of Sciences Publication Activity Database

    Dobeš, M.; Martínek, J.; Skoupil, D.; Dobešová, Z.; Pospíšil, Jaroslav

    2006-01-01

    Roč. 117, - (2006), s. 468-473 ISSN 0030-4026 Institutional research plan: CEZ:AV0Z10100522 Keywords : human eye localization * modified Hough transform * eye iris and eyelid shape determination Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.585, year: 2006

  9. Relating Eye Activity Measures to Human Controller Remnant Characteristics

    NARCIS (Netherlands)

    Popovici, A; Zaal, P.M.T.; Pool, D.M.; Mulder, M.; Sawaragi, T

    2016-01-01

    This study attempts to partially explain the characteristics of the human perceptual remnant, following Levison’s representation of the remnant as an equivalent observation noise. Eye activity parameters are recorded using an eye tracker in two compensatory tracking tasks in which the visual

  10. Human eye colour and HERC2, OCA2 and MATP

    DEFF Research Database (Denmark)

    Mengel-From, Jonas; Børsting, Claus; Sanchez, Juan J

    2010-01-01

    Prediction of human eye colour by forensic genetic methods is of great value in certain crime investigations. Strong associations between blue/brown eye colour and the SNP loci rs1129038 and rs12913832 in the HERC2 gene were recently described. Weaker associations between eye colour and other...... genetic markers also exist. In 395 randomly selected Danes, we investigated the predictive values of various combinations of SNP alleles in the HERC2, OCA2 and MATP (SLC45A2) genes and compared the results to the eye colours as they were described by the individuals themselves. The highest predictive...

  11. Stress free configuration of the human eye.

    Science.gov (United States)

    Elsheikh, Ahmed; Whitford, Charles; Hamarashid, Rosti; Kassem, Wael; Joda, Akram; Büchler, Philippe

    2013-02-01

    Numerical simulations of eye globes often rely on topographies that have been measured in vivo using devices such as the Pentacam or OCT. The topographies, which represent the form of the already stressed eye under the existing intraocular pressure, introduce approximations in the analysis. The accuracy of the simulations could be improved if either the stress state of the eye under the effect of intraocular pressure is determined, or the stress-free form of the eye estimated prior to conducting the analysis. This study reviews earlier attempts to address this problem and assesses the performance of an iterative technique proposed by Pandolfi and Holzapfel [1], which is both simple to implement and promises high accuracy in estimating the eye's stress-free form. A parametric study has been conducted and demonstrated reliance of the error level on the level of flexibility of the eye model, especially in the cornea region. However, in all cases considered 3-4 analysis iterations were sufficient to produce a stress-free form with average errors in node location <10(-6)mm and a maximal error <10(-4)mm. This error level, which is similar to what has been achieved with other methods and orders of magnitude lower than the accuracy of current clinical topography systems, justifies the use of the technique as a pre-processing step in ocular numerical simulations. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  12. Simulation of wave propagation inside a human eye: acoustic eye model (AEM)

    Science.gov (United States)

    Požar, T.; Halilovič, M.; Horvat, D.; Petkovšek, R.

    2018-02-01

    The design and development of the acoustic eye model (AEM) is reported. The model consists of a computer-based simulation that describes the propagation of mechanical disturbance inside a simplified model of a human eye. The capabilities of the model are illustrated with examples, using different laser-induced initial loading conditions in different geometrical configurations typically occurring in ophthalmic medical procedures. The potential of the AEM is to predict the mechanical response of the treated eye tissue in advance, thus complementing other preliminary procedures preceding medical treatments.

  13. Human eye colour and HERC2, OCA2 and MATP

    DEFF Research Database (Denmark)

    Mengel-From, Jonas; Børsting, Claus; Sanchez, Juan J.

    2010-01-01

    Prediction of human eye colour by forensic genetic methods is of great value in certain crime investigations. Strong associations between blue/brown eye colour and the SNP loci rs1129038 and rs12913832 in the HERC2 gene were recently described. Weaker associations between eye colour and other...... value of typing either the HERC2 SNPs rs1129038 and/or rs12913832 that are in strong linkage disequilibrium was observed when eye colour was divided into two groups, (1) blue, grey and green (light) and (2) brown and hazel (dark). Sequence variations in rs11636232 and rs7170852 in HERC2, rs1800407...... genetic markers also exist. In 395 randomly selected Danes, we investigated the predictive values of various combinations of SNP alleles in the HERC2, OCA2 and MATP (SLC45A2) genes and compared the results to the eye colours as they were described by the individuals themselves. The highest predictive...

  14. Basement membrane abnormalities in human eyes with diabetic retinopathy

    DEFF Research Database (Denmark)

    Ljubimov, A V; Burgeson, R E; Butkowski, R J

    1996-01-01

    Vascular and parenchymal basement membranes (BMs) are thickened in diabetes, but alterations in individual BM components in diabetic eyes, especially in diabetic retinopathy (DR), are obscure. To identify abnormalities in the distribution of specific constituents, we analyzed cryostat sections...... of human eyes obtained at autopsy (seven normal, five diabetic without DR, and 13 diabetic with DR) by immunofluorescence with antibodies to 30 BM and extracellular matrix components. In non-DR eyes, no qualitative changes of ocular BM components were seen. In some DR corneas, epithelial BM was stained...... discontinuously for laminin-1, entactin/nidogen, and alpha3-alpha4 Type IV collagen, in contrast to non-DR corneas. Major BM alterations were found in DR retinas compared to normals and non-DR diabetics. The inner limiting membrane (retinal BM) of DR eyes had accumulations of fibronectin (including cellular...

  15. Effect of aberrations in human eye on contrast sensitivity function

    Science.gov (United States)

    Quan, Wei; Wang, Feng-lin; Wang, Zhao-qi

    2011-06-01

    The quantitative analysis of the effect of aberrations in human eye on vision has important clinical value in the correction of aberrations. The wave-front aberrations of human eyes were measured with the Hartmann-Shack wave-front sensor and modulation transfer function (MTF) was computed from the wave-front aberrations. Contrast sensitivity function (CSF) was obtained from MTF and the retinal aerial image modulation (AIM). It is shown that the 2nd, 3rd, 4th, 5th, 6th Zernike aberrations deteriorate contrast sensitivity function. When the 2nd, 3rd, 4th, 5th, 6th Zernike aberrations are corrected high contrast sensitivity function can be obtained.

  16. Molecular Diagnosis of Human Taenia martis Eye Infection.

    Science.gov (United States)

    Koch, Till; Schoen, Christoph; Muntau, Birgit; Addo, Marylyn; Ostertag, Helmut; Wiechens, Burkhard; Tappe, Dennis

    2016-05-04

    Taenia martis, a tapeworm harbored in the intestine of mustelids, is a rarely encountered zoonotic cysticercosis pathogen. The larval stage closely resembles the Taenia solium cysticercus, but the natural host and thus the epidemiology of the disease is different. We here report a human eye infection diagnosed molecularly in a previously healthy female German patient. The case represents the third human infection described worldwide; the two previous cases were also European, involving eye and brain. © The American Society of Tropical Medicine and Hygiene.

  17. Effect of Hemodialysis on Eye Coats, Axial Length, and Ocular Perfusion Pressure in Patients with Chronic Renal Failure

    Directory of Open Access Journals (Sweden)

    Ling Wang

    2018-01-01

    Full Text Available Purpose. To investigate changes in eye coats, axial length, and ocular perfusion pressure (OPP in hemodialysis (HD patients with chronic renal failure (CRF. Methods. We included HD patients who were diagnosed with CRF in our hospital from January to December 2015. Fifty-two patients met the inclusion criteria; all right eyes were used for observation. Systolic and diastolic blood pressures were recorded to calculate OPP. Approximately 30 minutes before and after HD, we recorded multiple parameters, including lens thickness (LT, axial length of vitreous (VAL, axial length of eye (EAL, ciliary body thickness (CBT, choroidal thickness (CT, and retinal thickness (RT. Results. After HD, OPP significantly decreased (P<0.01, F=7.023 and CBT became significantly thinner (P<0.01, t=3.461. CT was significantly thinner and differed among measurement locations (P<0.01, t=6.240; P<0.01, t=6.169; P<0.01, t=3.405, respectively, fovea, nasal, and temporal side 1500 μm beside the fovea. Further, RT thickened and differed among measurement locations (P<0.05, t=−2.265; P<0.05, t=−2.624; P<0.05, t=−2.220, respectively, fovea, nasal, and temporal side 1500 μm beside fovea, whereas LT, VAL, and EAL significantly increased after HD (P<0.05, t=−2.076; P<0.01, t=−3.817; P<0.01, t=−4.010. Conclusions. HD impacts the thickness of the eye coats and VAL, particularly affecting CBT, CT, and RT. OPP transiently decreases during HD, which may contribute to an ischemic state.

  18. Human volunteer study with PGME: Eye irritation during vapour exposure

    NARCIS (Netherlands)

    Emmen, H.H.; Muijser, H.; Arts, J.H.E.; Prinsen, M.K.

    2003-01-01

    The objective of this study was to establish the possible occurrence of eye irritation and subjective symptoms in human volunteers exposed to propylene glycol monomethyl ether (PGME) vapour at concentrations of 0, 100 and 150 ppm. Testing was conducted in 12 healthy male volunteers using a repeated

  19. Human rights: eye for cultural diversity

    NARCIS (Netherlands)

    Donders, Y.M.

    2012-01-01

    The relationship and interaction between international human rights law and cultural diversity is a current topic, as is shown by the recent debates in The Netherlands on, for instance, the proposed ban on wearing facial coverage, or burqas, and the proposed ban on ritual slaughter without

  20. Prediction of human eye fixations using symmetry

    NARCIS (Netherlands)

    Kootstra, Gert; Schomaker, Lambert

    2009-01-01

    Humans are very sensitive to symmetry in visual patterns. Reaction time experiments show that symmetry is detected and recognized very rapidly. This suggests that symmetry is a highly salient feature. Existing computational models of saliency, however, have mainly focused on contrast as a measure of

  1. Effects of flickering light on refraction and changes in eye axial length of C57BL/6 mice.

    Science.gov (United States)

    Yu, Ying; Chen, Hui; Tuo, Jingsheng; Zhu, Yin

    2011-01-01

    To investigate the effectiveness and feasibility of inducing myopia in mice by flickering-light (FL) stimulation. Forty-five 28-day-old C57BL/6 (B6) mice were randomly assigned to three groups: control group, FL stimulation group and form deprivation (FD) group. Mice in the control group were raised under 250 lux illumination from 8:00 a.m. to 8:00 p.m. Mice in the FL group were raised under illumination with a duty cycle of 50% at a flash rate of 2 Hz from 8:00 a.m. to 8:00 p.m. for 6 weeks. Mice in the FD group were raised under the same conditions as the control group; the right eyes of the mice were covered with semitransparent hemispherical plastic shells serving as eye diffusers. The refractive state and axial length (AL) of the right eyes were measured by eccentric infrared photorefraction and A-scan ultrasonography, respectively, before treatment and after 2, 4, 6 or 8 weeks' treatment. After 6 weeks' exposure to FL, the refraction became more myopic compared with the control group as indicated by longer AL compared with the control group (p < 0.05); the FD eyes were more myopic than the FL eyes (p < 0.05). However, some mice lost their eye diffusers, and lens opacities were found. Myopia can be induced by FL in B6 mice. The myopic shift induced by FL is less than that induced by FD, but FL causes fewer side effects, and is safery and easier to manipulate. Copyright © 2011 S. Karger AG, Basel.

  2. Multiphoton tomography of the human eye

    Science.gov (United States)

    König, Karsten; Batista, Ana; Hager, Tobias; Seitz, Berthold

    2017-02-01

    Multiphoton tomography (MPT) is a novel label-free clinical imaging method for non-invasive tissue imaging with high spatial (300 nm) and temporal (100 ps) resolutions. In vivo optical histology can be realized due to the nonlinear excitation of endogenous fluorophores and second-harmonic generation (SHG) of collagen. Furthermore, optical metabolic imaging (OMI) is performed by two-photon autofluorescence lifetime imaging (FLIM). So far, applications of the multiphoton tomographs DermaInspect and MPTflex were limited to dermatology. Novel applications include intraoperative brain tumor imaging as well as cornea imaging. In this work we describe two-photon imaging of ex vivo human corneas unsuitable for transplantation. Furthermore, the cross-linking (CXL) process of corneal collagen based on UVA exposure and 0.1 % riboflavin was studied. The pharmacokinetics of the photosensitizer could be detected with high spatial resolution. Interestingly, an increase in the stromal autofluorescence intensity and modifications of the autofluorescence lifetimes were observed in the human corneal samples within a few days following CXL.

  3. Design of an in-vivo microscope to characterize cataracts in human eyes

    Science.gov (United States)

    Feng, Chen; Ahmad, Anees

    1996-11-01

    The design of a compact contact microscope, which can be used in-vivo to study the cataracts in human eyes is presented. This microscope has the capability to evaluate the changes in the optical density within the eye lens itself, and thus enabling an examiner to ascertain the progression of a cataractous change or at least the optical changes associated with cataractous development. The microscope has a variable focal length so it can be focused at any depth through the entire thickness of the eye lens. A separate small objective lens is spring loaded against the cornea (like a tonometer tip) so that the natural eye movements can occur safely during the examination. The distance between the objective lens and rest of the optics is variable to accommodate the movements of the eye due to pulse or breathing without affecting the image quality of the instrument. The layer by layer images can be captured on a CCD camera and stored in the computer. The reconstruction software can quantitatively display the characteristics of the cataracts, such as the location, size, and density. The optical design and performance results for the microscope are presented. The optomechanical design features of the microscope are also discussed.

  4. Ray tracing for inhomogeneous media applied to the human eye

    Science.gov (United States)

    Diaz-Gonzalez, G.; Iturbe-Castillo, M. D.; Juarez-Salazar, R.

    2017-08-01

    Inhomogeneous or gradient index media exhibit a refractive index varying with the position. This kind of media are very interesting because they can be found in both synthetic as well as real life optical devices such as the human lens. In this work we present the development of a computational tool for ray tracing in refractive optical systems. Particularly, the human eye is used as the optical system under study. An inhomogeneous medium with similar characteristics to the human lens is introduced and modeled by the so-called slices method. The useful of our proposal is illustrated by several graphical results.

  5. Region of eye contact of humanoid Nao robot is similar to that of a human

    NARCIS (Netherlands)

    Cuijpers, R.H.; Pol, van der D.; Herrmann, G.; Pearson, M.J.; Lenz, A.; Bremner, P.; Spiers, A.; Leonards, U.

    2013-01-01

    Eye contact is an important social cue in human-human interaction, but it is unclear how easily it carries over to humanoid robots. In this study we investigated whether the tolerance of making eye contact is similar for the Nao robot as compared to human lookers. We measured the region of eye

  6. Wavefront sensorless adaptive optics ophthalmoscopy in the human eye

    Science.gov (United States)

    Hofer, Heidi; Sredar, Nripun; Queener, Hope; Li, Chaohong; Porter, Jason

    2011-01-01

    Wavefront sensor noise and fidelity place a fundamental limit on achievable image quality in current adaptive optics ophthalmoscopes. Additionally, the wavefront sensor ‘beacon’ can interfere with visual experiments. We demonstrate real-time (25 Hz), wavefront sensorless adaptive optics imaging in the living human eye with image quality rivaling that of wavefront sensor based control in the same system. A stochastic parallel gradient descent algorithm directly optimized the mean intensity in retinal image frames acquired with a confocal adaptive optics scanning laser ophthalmoscope (AOSLO). When imaging through natural, undilated pupils, both control methods resulted in comparable mean image intensities. However, when imaging through dilated pupils, image intensity was generally higher following wavefront sensor-based control. Despite the typically reduced intensity, image contrast was higher, on average, with sensorless control. Wavefront sensorless control is a viable option for imaging the living human eye and future refinements of this technique may result in even greater optical gains. PMID:21934779

  7. Eye movements and word skipping during reading: Effects of word length and predictability

    Science.gov (United States)

    Rayner, Keith; Slattery, Timothy J.; Drieghe, Denis; Liversedge, Simon P.

    2012-01-01

    The extent to which target words were predictable from prior context was varied: half of the target words were predictable and the other half were unpredictable. In addition, the length of the target word varied: the target words were short (4–6 letters), medium (7–9 letters), or long (10–12 letters). Length and predictability both yielded strong effects on the probability of skipping the target words and on the amount of time readers fixated the target words (when they were not skipped). However, there was no interaction in any of the measures examined for either skipping or fixation time. The results demonstrate that word predictability (due to contextual constraint) and word length have strong and independent influences on word skipping and fixation durations. Furthermore, since the long words extended beyond the word identification span, the data indicate that skipping can occur on the basis of partial information in relation to word identity. PMID:21463086

  8. Telomere length modulation in human astroglial brain tumors.

    Directory of Open Access Journals (Sweden)

    Domenico La Torre

    Full Text Available BACKGROUND: Telomeres alteration during carcinogenesis and tumor progression has been described in several cancer types. Telomeres length is stabilized by telomerase (h-TERT and controlled by several proteins that protect telomere integrity, such as the Telomere Repeat-binding Factor (TRF 1 and 2 and the tankyrase-poli-ADP-ribose polymerase (TANKs-PARP complex. OBJECTIVE: To investigate telomere dysfunction in astroglial brain tumors we analyzed telomeres length, telomerase activity and the expression of a panel of genes controlling the length and structure of telomeres in tissue samples obtained in vivo from astroglial brain tumors with different grade of malignancy. MATERIALS AND METHODS: Eight Low Grade Astrocytomas (LGA, 11 Anaplastic Astrocytomas (AA and 11 Glioblastoma Multiforme (GBM samples were analyzed. Three samples of normal brain tissue (NBT were used as controls. Telomeres length was assessed through Southern Blotting. Telomerase activity was evaluated by a telomere repeat amplification protocol (TRAP assay. The expression levels of TRF1, TRF2, h-TERT and TANKs-PARP complex were determined through Immunoblotting and RT-PCR. RESULTS: LGA were featured by an up-regulation of TRF1 and 2 and by shorter telomeres. Conversely, AA and GBM were featured by a down-regulation of TRF1 and 2 and an up-regulation of both telomerase and TANKs-PARP complex. CONCLUSIONS: In human astroglial brain tumours, up-regulation of TRF1 and TRF2 occurs in the early stages of carcinogenesis determining telomeres shortening and genomic instability. In a later stage, up-regulation of PARP-TANKs and telomerase activation may occur together with an ADP-ribosylation of TRF1, causing a reduced ability to bind telomeric DNA, telomeres elongation and tumor malignant progression.

  9. ESTIMATION OF MELANIN CONTENT IN IRIS OF HUMAN EYE

    Directory of Open Access Journals (Sweden)

    E. A. Genina

    2008-12-01

    Full Text Available Based on the experimental data obtained in vivo from digital analysis of color images of human irises, the mean melanin content in human eye irises has been estimated. For registration of color images the digital camera Olympus C-5060 has been used. The images have been obtained from irises of healthy volunteers as well as from irises of patients with open-angle glaucoma. The computer program has been developed for digital analysis of the images. The result has been useful for development of novel methods and optimization of already existing ones for non-invasive glaucoma diagnostics.

  10. Constructing a Computer Model of the Human Eye Based on Tissue Slice Images

    OpenAIRE

    Dai, Peishan; Wang, Boliang; Bao, Chunbo; Ju, Ying

    2010-01-01

    Computer simulation of the biomechanical and biological heat transfer in ophthalmology greatly relies on having a reliable computer model of the human eye. This paper proposes a novel method on the construction of a geometric model of the human eye based on tissue slice images. Slice images were obtained from an in vitro Chinese human eye through an embryo specimen processing methods. A level set algorithm was used to extract contour points of eye tissues while a principle component analysi...

  11. Comparison of axial length, anterior chamber depth and intraocular lens power between IOLMaster and ultrasound in normal, long and short eyes.

    Science.gov (United States)

    Dong, Jing; Zhang, Yaqin; Zhang, Haining; Jia, Zhijie; Zhang, Suhua; Wang, Xiaogang

    2018-01-01

    To compare the axial length (AL), anterior chamber depth (ACD) and intraocular lens power (IOLP) of IOLMaster and Ultrasound in normal, long and short eyes. Seventy-four normal eyes (≥ 22 mm and ≤ 25 mm), 74 long eyes (> 25 mm) and 78 short eyes (devices in the order of IOLMaster followed by Ultrasound. The IOLP were calculated using a free online LADAS IOL formula calculator. The difference in AL and IOLP between IOLMaster and Ultrasound was statistically significant when all three groups were combined. The difference in ACD between IOLMaster and Ultrasound was statistically significant in the normal group (Peye group (Peye group (P = 0.465). For the IOLP difference between IOLMaster and Ultrasound in the normal group, the percentage of IOLP differences eye group, they were 90.5%, 5.4%, 4.1% and 0%, respectively. For the short eye group, they were 61.5%, 23.1%, 10.3%, and 5.1%, respectively. IOLMaster and Ultrasound have statistically significant differences in AL measurements and IOLP (using LADAS formula) for normal, long eye and short eye. The two instruments agree regarding ACD measurements for the long eye group, but differ for the normal and short eye groups. Moreover, the high percentage of IOLP differences greater than |0.5|D in the short eye group is noteworthy.

  12. Directional asymmetries in human smooth pursuit eye movements.

    Science.gov (United States)

    Ke, Sally R; Lam, Jessica; Pai, Dinesh K; Spering, Miriam

    2013-06-27

    Humans make smooth pursuit eye movements to bring the image of a moving object onto the fovea. Although pursuit accuracy is critical to prevent motion blur, the eye often falls behind the target. Previous studies suggest that pursuit accuracy differs between motion directions. Here, we systematically assess asymmetries in smooth pursuit. In experiment 1, binocular eye movements were recorded while observers (n = 20) tracked a small spot of light moving along one of four cardinal or diagonal axes across a featureless background. We analyzed pursuit latency, acceleration, peak velocity, gain, and catch-up saccade latency, number, and amplitude. In experiment 2 (n = 22), we examined the effects of spatial location and constrained stimulus motion within the upper or lower visual field. Pursuit was significantly faster (higher acceleration, peak velocity, and gain) and smoother (fewer and later catch-up saccades) in response to downward versus upward motion in both the upper and the lower visual fields. Pursuit was also more accurate and smoother in response to horizontal versus vertical motion. CONCLUSIONS. Our study is the first to report a consistent up-down asymmetry in human adults, regardless of visual field. Our findings suggest that pursuit asymmetries are adaptive responses to the requirements of the visual context: preferred motion directions (horizontal and downward) are more critical to our survival than nonpreferred ones.

  13. Isoplanatic patch of the human eye for arbitrary wavelengths

    Science.gov (United States)

    Han, Guoqing; Cao, Zhaoliang; Mu, Quanquan; Wang, Yukun; Li, Dayu; Wang, Shaoxin; Xu, Zihao; Wu, Daosheng; Hu, Lifa; Xuan, Li

    2018-03-01

    The isoplanatic patch of the human eye is a key parameter for the adaptive optics system (AOS) designed for retinal imaging. The field of view (FOV) usually sets to the same size as the isoplanatic patch to obtain high resolution images. However, it has only been measured at a specific wavelength. Here we investigate the wavelength dependence of this important parameter. An optical setup is initially designed and established in a laboratory to measure the isoplanatic patch at various wavelengths (655 nm, 730 nm and 808 nm). We established the Navarro wide-angle eye model in Zemax software to further validate our results, which suggested high consistency between the two. The isoplanatic patch as a function of wavelength was obtained within the range of visible to near-infrared, which can be expressed as: θ=0.0028 λ - 0 . 74. This work is beneficial for the AOS design for retinal imaging.

  14. Three-dimensional ray tracing for refractive correction of human eye ametropies

    Science.gov (United States)

    Jimenez-Hernandez, J. A.; Diaz-Gonzalez, G.; Trujillo-Romero, F.; Iturbe-Castillo, M. D.; Juarez-Salazar, R.; Santiago-Alvarado, A.

    2016-09-01

    Ametropies of the human eye, are refractive defects hampering the correct imaging on the retina. The most common ways to correct them is by means of spectacles, contact lenses, and modern methods as laser surgery. However, in any case it is very important to identify the ametropia grade for designing the optimum correction action. In the case of laser surgery, it is necessary to define a new shape of the cornea in order to obtain the wanted refractive correction. Therefore, a computational tool to calculate the focal length of the optical system of the eye versus variations on its geometrical parameters is required. Additionally, a clear and understandable visualization of the evaluation process is desirable. In this work, a model of the human eye based on geometrical optics principles is presented. Simulations of light rays coming from a punctual source at six meter from the cornea are shown. We perform a ray-tracing in three dimensions in order to visualize the focusing regions and estimate the power of the optical system. The common parameters of ametropies can be easily modified and analyzed in the simulation by an intuitive graphic user interface.

  15. Eye movements reveal epistemic curiosity in human observers.

    Science.gov (United States)

    Baranes, Adrien; Oudeyer, Pierre-Yves; Gottlieb, Jacqueline

    2015-12-01

    Saccadic (rapid) eye movements are primary means by which humans and non-human primates sample visual information. However, while saccadic decisions are intensively investigated in instrumental contexts where saccades guide subsequent actions, it is largely unknown how they may be influenced by curiosity - the intrinsic desire to learn. While saccades are sensitive to visual novelty and visual surprise, no study has examined their relation to epistemic curiosity - interest in symbolic, semantic information. To investigate this question, we tracked the eye movements of human observers while they read trivia questions and, after a brief delay, were visually given the answer. We show that higher curiosity was associated with earlier anticipatory orienting of gaze toward the answer location without changes in other metrics of saccades or fixations, and that these influences were distinct from those produced by variations in confidence and surprise. Across subjects, the enhancement of anticipatory gaze was correlated with measures of trait curiosity from personality questionnaires. Finally, a machine learning algorithm could predict curiosity in a cross-subject manner, relying primarily on statistical features of the gaze position before the answer onset and independently of covariations in confidence or surprise, suggesting potential practical applications for educational technologies, recommender systems and research in cognitive sciences. With this article, we provide full access to the annotated database allowing readers to reproduce the results. Epistemic curiosity produces specific effects on oculomotor anticipation that can be used to read out curiosity states. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  16. Haldane’s Rule Is Linked to Extraordinary Sex Ratios and Sperm Length in Stalk-Eyed Flies

    Science.gov (United States)

    Wilkinson, Gerald S.; Christianson, Sarah J.; Brand, Cara L.; Ru, George; Shell, Wyatt

    2014-01-01

    We use three allopatric populations of the stalk-eyed fly Teleopsis dalmanni from Southeast Asia to test two predictions made by the sex chromosome drive hypothesis for Haldane’s rule. The first is that modifiers that suppress or enhance drive should evolve rapidly and independently in isolated populations. The second is that drive loci or modifiers should also cause sterility in hybrid males. We tested these predictions by assaying the fertility of 2066 males derived from backcross experiments involving two pairs of populations and found that the proportion of mated males that fail to produce any offspring ranged from 38 to 60% among crosses with some males producing strongly female-biased or male-biased sex ratios. After genotyping each male at 25–28 genetic markers we found quantitative trait loci (QTL) that jointly influence male sterility, sperm length, and biased progeny sex ratios in each pair of populations, but almost no shared QTL between population crosses. We also discovered that the extant XSR chromosome has no effect on sex ratio or sterility in these backcross males. Whether shared QTL are caused by linkage or pleiotropy requires additional study. Nevertheless, these results indicate the presence of a “cryptic” drive system that is currently masked by suppressing elements that are associated with sterility and sperm length within but not between populations and, therefore, must have evolved since the populations became isolated, i.e., in hybrid sterility. PMID:25164880

  17. A boundary element model for investigating the effects of eye tumor on the temperature distribution inside the human eye.

    Science.gov (United States)

    Ooi, E H; Ang, W T; Ng, E Y K

    2009-08-01

    A three-dimensional boundary element model of the human eye is developed to investigate the thermal effects of eye tumor on the ocular temperature distribution. The human eye is modeled as comprising several regions which have different thermal properties. The tumor is one of these regions. The thermal effects of the tumor are simulated by taking it to have a very high metabolic heat generation and blood perfusion rate. Inside the tumor, the steady state temperature is governed by the Pennes bioheat equation. Elsewhere, in normal tissues of the eye, the temperature satisfies the Laplace's equation. To compute the temperature on the corneal surface, the surface boundary of each region is divided into triangular elements.

  18. Comparative Analysis of Gene Expression for Convergent Evolution of Camera Eye Between Octopus and Human

    Science.gov (United States)

    Ogura, Atsushi; Ikeo, Kazuho; Gojobori, Takashi

    2004-01-01

    Although the camera eye of the octopus is very similar to that of humans, phylogenetic and embryological analyses have suggested that their camera eyes have been acquired independently. It has been known as a typical example of convergent evolution. To study the molecular basis of convergent evolution of camera eyes, we conducted a comparative analysis of gene expression in octopus and human camera eyes. We sequenced 16,432 ESTs of the octopus eye, leading to 1052 nonredundant genes that have matches in the protein database. Comparing these 1052 genes with 13,303 already-known ESTs of the human eye, 729 (69.3%) genes were commonly expressed between the human and octopus eyes. On the contrary, when we compared octopus eye ESTs with human connective tissue ESTs, the expression similarity was quite low. To trace the evolutionary changes that are potentially responsible for camera eye formation, we also compared octopus-eye ESTs with the completed genome sequences of other organisms. We found that 1019 out of the 1052 genes had already existed at the common ancestor of bilateria, and 875 genes were conserved between humans and octopuses. It suggests that a larger number of conserved genes and their similar gene expression may be responsible for the convergent evolution of the camera eye. PMID:15289475

  19. Genetic analyses of the human eye colours using a novel objective method for eye colour classification

    DEFF Research Database (Denmark)

    Andersen, Jeppe D.; Johansen, Peter; Harder, Stine

    2013-01-01

    In this study, we present a new objective method for measuring the eye colour on a continuous scale that allows researchers to associate genetic markers with different shades of eye colour. With the use of the custom designed software Digital Iris Analysis Tool (DIAT), the iris was automatically...... and TYR rs1393350) on the eye colour. We evaluated the two published prediction models for eye colour (IrisPlex [1] and Snipper[2]) and compared the predictions with the PIE-scores. We found good concordance with the prediction from individuals typed as HERC2 rs12913832 G. However, both methods had......-score ranged from −1 to 1 (brown to blue). The software eliminated the need for user based interpretation and qualitative eye colour categories. In 94% (570) of 605 analyzed eye images, the iris region was successfully extracted and a PIE-score was calculated. A very high correlation between the PIE...

  20. Can human eyes prevent perceptual narrowing for monkey faces in human infants?

    Science.gov (United States)

    Damon, Fabrice; Bayet, Laurie; Quinn, Paul C; Hillairet de Boisferon, Anne; Méary, David; Dupierrix, Eve; Lee, Kang; Pascalis, Olivier

    2015-07-01

    Perceptual narrowing has been observed in human infants for monkey faces: 6-month-olds can discriminate between them, whereas older infants from 9 months of age display difficulty discriminating between them. The difficulty infants from 9 months have processing monkey faces has not been clearly identified. It could be due to the structural characteristics of monkey faces, particularly the key facial features that differ from human faces. The current study aimed to investigate whether the information conveyed by the eyes is of importance. We examined whether the presence of Caucasian human eyes in monkey faces allows recognition to be maintained in 6-month-olds and facilitates recognition in 9- and 12-month-olds. Our results revealed that the presence of human eyes in monkey faces maintains recognition for those faces at 6 months of age and partially facilitates recognition of those faces at 9 months of age, but not at 12 months of age. The findings are interpreted in the context of perceptual narrowing and suggest that the attenuation of processing of other-species faces is not reversed by the presence of human eyes. © 2015 Wiley Periodicals, Inc.

  1. Human vertical eye movement responses to earth horizontal pitch

    Science.gov (United States)

    Wall, C. 3rd; Petropoulos, A. E.

    1993-01-01

    The vertical eye movements in humans produced in response to head-over-heels constant velocity pitch rotation about a horizontal axis resemble those from other species. At 60 degrees/s these are persistent and tend to have non-reversing slow components that are compensatory to the direction of rotation. In most, but not all subjects, the slow component velocity was well characterized by a rapid build-up followed by an exponential decay to a non-zero baseline. Super-imposed was a cyclic or modulation component whose frequency corresponded to the time for one revolution and whose maximum amplitude occurred during a specific head orientation. All response components (exponential decay, baseline and modulation) were larger during pitch backward compared to pitch forward runs. Decay time constants were shorter during the backward runs, thus, unlike left to right yaw axis rotation, pitch responses display significant asymmetries between paired forward and backward runs.

  2. Noninvasive detection of macular pigments in the human eye.

    Science.gov (United States)

    Gellermann, Werner; Bernstein, Paul S

    2004-01-01

    There is currently strong interest in developing noninvasive technologies for the detection of macular carotenoid pigments in the human eye. These pigments, consisting of lutein and zeaxanthin, are taken up from the diet and are thought to play an important role in the prevention of age-related macular degeneration, the leading cause of blindness in the elderly in the Western world. It may be possible to prevent or delay the onset of this debilitating disease with suitable dietary intervention strategies. We review the most commonly used detection techniques based on heterochromatic flicker photometry, fundus reflectometry, and autofluorescense techniques and put them in perspective with recently developed more molecule-specific Raman detection methods. (c) 2004 Society of Photo-Optical Instrumentation Engineers.

  3. Composite modified Luneburg model of human eye lens.

    Science.gov (United States)

    Gómez-Correa, J E; Balderas-Mata, S E; Pierscionek, B K; Chávez-Cerda, S

    2015-09-01

    A new lens model based on the gradient-index Luneburg lens and composed of two oblate half spheroids of different curvatures is presented. The spherically symmetric Luneburg lens is modified to create continuous isoindicial contours and to incorporate curvatures that are similar to those found in a human lens. The imaging capabilities of the model and the changes in the gradient index profile are tested for five object distances, for a fixed geometry and for a fixed image distance. The central refractive index decreases with decreasing object distance. This indicates that in order to focus at the same image distance as is required in the eye, a decrease in refractive power is needed for rays from closer objects that meet the lens surface at steeper angles compared to rays from more distant objects. This ensures a highly focused image with no spherical aberration.

  4. Monte-Carlo simulation of proton radiotherapy for human eye

    International Nuclear Information System (INIS)

    Liu Yunpeng; Tang Xiaobin; Xie Qin; Chen Feida; Geng Changran; Chen Da

    2010-01-01

    The 62 MeV proton beam was selected to develop a MCNPX model of the human eye to approximate dose delivered from proton therapy by. In the course of proton therapy, two treatment simulations were considered. The first simulation was an ideal treatment scenario. In this case, the dose of tumor was 50.03 Gy, which was at the level of effective treatment, while other organizations were in the range of acceptable dose. The second case was a worst case scenario to simulate a patient gazing directly into the treatment beam during therapy. The bulk of dose deposited in the cornea, lens, and anterior chamber region. However, the dose of tumor area was zero. The calculated results show an agreement accordance with the relative reference, which confirmed that the MCNPX code can simulate proton radiotherapy perfectly, and is a capable platform for patient planning. The data from the worst case can be used for dose reconstruction of the clinical accident. (authors)

  5. Simultaneous measurement of eye stiffness and contact area for living human eyes.

    Science.gov (United States)

    Kurita, Yuichi; Iida, Yoshichika; Kaneko, Makoto; Mishima, Hiromu K; Katakura, Seiki; Kiuchi, Yoshiaki

    2007-01-01

    Goldmann applanation tonometry is commonly used for measuring IOP (IntraOcular Pressure) to diagnose glaucoma. However, the measured IOP by the applanation tonometry is valid only under the assumption that all the subjects have the same structural eye stiffness. Abnormal eye stiffness makes abnormal corneal deformation and thus the current applanation tonometer misestimates the IOP. This study challenges to measure the eye stiffness in vivo with a non-invasive approach for detecting the abnormal deformation. The deformation of the cornea and the contact area between the probe and the cornea are simultaneously captured by cameras during the experiment. Experimental results show that some subjects have different relationship among the force, the displacement and the contact area even with same IOP. The proposed eye stiffness measurement can help detecting the abnormal deformation and the eyes with misestimated IOP.

  6. Human behavioral biology: commentary on Lerner and von Eye's sociobiology and human development

    NARCIS (Netherlands)

    Molenaar, P.C.M.; Burgess, R.L.

    1993-01-01

    Contends that in their examination of arguments forwarded by sociobiologists to account for key features of human development, R. M. Lerner and A. von Eye (see record 1992-23071-001) misunderstand the role of general theory in science. They also fail to characterize the work of sociobiologists

  7. Effects of intraocular lenses with different diopters on chromatic aberrations in human eye models.

    Science.gov (United States)

    Song, Hui; Yuan, Xiaoyong; Tang, Xin

    2016-01-11

    In this study, the effects of intraocular lenses (IOLs) with different diopters (D) on chromatic aberration were investigated in human eye models, and the influences of the central thickness of IOLs on chromatic aberration were compared. A Liou-Brennan-based IOL eye model was constructed using ZEMAX optical design software. Spherical IOLs with different diopters (AR40e, AMO Company, USA) were implanted; modulation transfer function (MTF) values at 3 mm of pupil diameter and from 0 to out-of-focus blur were collected and graphed. MTF values, measured at 555 nm of monochromatic light under each spatial frequency, were significantly higher than the values measured at 470 to 650 nm of polychromatic light. The influences of chromatic aberration on MTF values decreased with the increase in IOL diopter when the spatial frequency was ≤12 c/d, while increased effects were observed when the spatial frequency was ≥15 c/d. The MTF values of each IOL eye model were significantly lower than the MTF values of the Liou-Brennan eye models when measured at 555 nm of monochromatic light and at 470 to 650 nm of polychromatic light. The MTF values were also found to be increased with the increase in IOL diopter. With higher diopters of IOLs, the central thickness increased accordingly, which could have created increased chromatic aberration and decreased the retinal image quality. To improve the postoperative visual quality, IOLs with lower chromatic aberration should be selected for patients with short axial lengths.

  8. Visual Positioning Indoors: Human Eyes vs. Smartphone Cameras.

    Science.gov (United States)

    Wu, Dewen; Chen, Ruizhi; Chen, Liang

    2017-11-16

    Artificial Intelligence (AI) technologies and their related applications are now developing at a rapid pace. Indoor positioning will be one of the core technologies that enable AI applications because people spend 80% of their time indoors. Humans can locate themselves related to a visually well-defined object, e.g., a door, based on their visual observations. Can a smartphone camera do a similar job when it points to an object? In this paper, a visual positioning solution was developed based on a single image captured from a smartphone camera pointing to a well-defined object. The smartphone camera simulates the process of human eyes for the purpose of relatively locating themselves against a well-defined object. Extensive experiments were conducted with five types of smartphones on three different indoor settings, including a meeting room, a library, and a reading room. Experimental results shown that the average positioning accuracy of the solution based on five smartphone cameras is 30.6 cm, while that for the human-observed solution with 300 samples from 10 different people is 73.1 cm.

  9. Blue eyes in lemurs and humans: same phenotype, different genetic mechanism

    DEFF Research Database (Denmark)

    Bradley, Brenda J; Pedersen, Anja; Mundy, Nicholas I

    2009-01-01

    Almost all mammals have brown or darkly-pigmented eyes (irises), but among primates, there are some prominent blue-eyed exceptions. The blue eyes of some humans and lemurs are a striking example of convergent evolution of a rare phenotype on distant branches of the primate tree. Recent work...... on humans indicates that blue eye color is associated with, and likely caused by, a single nucleotide polymorphism (rs12913832) in an intron of the gene HERC2, which likely regulates expression of the neighboring pigmentation gene OCA2. This raises the immediate question of whether blue eyes in lemurs might...... have a similar genetic basis. We addressed this by sequencing the homologous genetic region in the blue-eyed black lemur (Eulemur macaco flavifrons; N = 4) and the closely-related black lemur (Eulemur macaco macaco; N = 4), which has brown eyes. We then compared a 166-bp segment corresponding...

  10. Controlled delivery of antiangiogenic drug to human eye tissue using a MEMS device

    KAUST Repository

    Pirmoradi, Fatemeh Nazly; Ou, Kevin; Jackson, John K.; Letchford, Kevin; Cui, Jing; Wolf, Ki Tae; Graber, Florian; Zhao, Tom; Matsubara, Joanne A.; Burt, Helen; Chiao, Mu; Lin, Liwei

    2013-01-01

    We demonstrate an implantable MEMS drug delivery device to conduct controlled and on-demand, ex vivo drug transport to human eye tissue. Remotely operated drug delivery to human post-mortem eyes was performed via a MEMS device. The developed curved

  11. Different cellular effects of four anti-inflammatory eye drops on human corneal epithelial cells: independent in active components

    OpenAIRE

    Qu, Mingli; Wang, Yao; Yang, Lingling; Zhou, Qingjun

    2011-01-01

    Purpose To evaluate and compare the cellular effects of four commercially available anti-inflammatory eye drops and their active components on human corneal epithelial cells (HCECs) in vitro. Methods The cellular effects of four eye drops (Bromfenac Sodium Hydrate Eye Drops, Pranoprofen Eye Drops, Diclofenac Sodium Eye Drops, and Tobramycin & Dex Eye Drops) and their corresponding active components were evaluated in an HCEC line with five in vitro assays. Cell proliferation and migration were...

  12. Implicit prosody mining based on the human eye image capture technology

    Science.gov (United States)

    Gao, Pei-pei; Liu, Feng

    2013-08-01

    The technology of eye tracker has become the main methods of analyzing the recognition issues in human-computer interaction. Human eye image capture is the key problem of the eye tracking. Based on further research, a new human-computer interaction method introduced to enrich the form of speech synthetic. We propose a method of Implicit Prosody mining based on the human eye image capture technology to extract the parameters from the image of human eyes when reading, control and drive prosody generation in speech synthesis, and establish prosodic model with high simulation accuracy. Duration model is key issues for prosody generation. For the duration model, this paper put forward a new idea for obtaining gaze duration of eyes when reading based on the eye image capture technology, and synchronous controlling this duration and pronunciation duration in speech synthesis. The movement of human eyes during reading is a comprehensive multi-factor interactive process, such as gaze, twitching and backsight. Therefore, how to extract the appropriate information from the image of human eyes need to be considered and the gaze regularity of eyes need to be obtained as references of modeling. Based on the analysis of current three kinds of eye movement control model and the characteristics of the Implicit Prosody reading, relative independence between speech processing system of text and eye movement control system was discussed. It was proved that under the same text familiarity condition, gaze duration of eyes when reading and internal voice pronunciation duration are synchronous. The eye gaze duration model based on the Chinese language level prosodic structure was presented to change previous methods of machine learning and probability forecasting, obtain readers' real internal reading rhythm and to synthesize voice with personalized rhythm. This research will enrich human-computer interactive form, and will be practical significance and application prospect in terms of

  13. High-throughput telomere length quantification by FISH and its application to human population studies.

    Science.gov (United States)

    Canela, Andrés; Vera, Elsa; Klatt, Peter; Blasco, María A

    2007-03-27

    A major limitation of studies of the relevance of telomere length to cancer and age-related diseases in human populations and to the development of telomere-based therapies has been the lack of suitable high-throughput (HT) assays to measure telomere length. We have developed an automated HT quantitative telomere FISH platform, HT quantitative FISH (Q-FISH), which allows the quantification of telomere length as well as percentage of short telomeres in large human sample sets. We show here that this technique provides the accuracy and sensitivity to uncover associations between telomere length and human disease.

  14. Intraocular Telescopic System Design: Optical and Visual Simulation in a Human Eye Model

    OpenAIRE

    Zoulinakis, Georgios; Ferrer-Blasco, Teresa

    2017-01-01

    Purpose. To design an intraocular telescopic system (ITS) for magnifying retinal image and to simulate its optical and visual performance after implantation in a human eye model. Methods. Design and simulation were carried out with a ray-tracing and optical design software. Two different ITS were designed, and their visual performance was simulated using the Liou-Brennan eye model. The difference between the ITS was their lenses’ placement in the eye model and their powers. Ray tracing in bot...

  15. Human eye modelling for ophthalmic simulators project for clinic applications

    International Nuclear Information System (INIS)

    Sanchez, Andrea; Santos, Adimir dos; Yoriyaz, Helio

    2002-01-01

    Most of eye tumors are treated by surgical means, which involves the enucleation of affected eyes. In terms of treatment and control of diseases, there is brachytherapy, which often utilizes small applicator of Co-60, I-125, Ru-106, Ir-192, etc. These methods are shown to be very efficient but highly cost. The objective of this work is propose a detailed simulator modelling for eye characterization. Additionally, this study can contribute to design and build a new applicator in order to reduce the cost and to allow more patients to be treated

  16. Human secretory phospholipase A(2), group IB in normal eyes and in eye diseases

    DEFF Research Database (Denmark)

    Kolko, Miriam; Prause, Jan U; Bazan, Nicolas G

    2007-01-01

    , retinitis pigmentosa and glaucoma were evaluated. RESULTS: Expression of hGIB was found in various cells of the eye. The most abundant expression was found in retinal pigment epithelium (RPE) cells, the inner photoreceptor segments, ganglion cells and the corneal endothelium. We explored diseases involving...

  17. Dating the time of birth: A radiocarbon calibration curve for human eye-lens crystallines

    DEFF Research Database (Denmark)

    Kjeldsen, Henrik; Heinemeier, Jan; Heegaard, Steffen

    2010-01-01

    Radiocarbon bomb-pulse dating has been used to measure the formation age of human eye-lens crystallines. Lens crystallines are special proteins in the eye-lens that consist of virtually inert tissue. The experimental data show that the radiocarbon ages to a large extent reflect the time of birth...

  18. Computational Model-Based Prediction of Human Episodic Memory Performance Based on Eye Movements

    Science.gov (United States)

    Sato, Naoyuki; Yamaguchi, Yoko

    Subjects' episodic memory performance is not simply reflected by eye movements. We use a ‘theta phase coding’ model of the hippocampus to predict subjects' memory performance from their eye movements. Results demonstrate the ability of the model to predict subjects' memory performance. These studies provide a novel approach to computational modeling in the human-machine interface.

  19. Human sensitivity to eye contact in 2D and 3D videoconferencing

    NARCIS (Netherlands)

    Eijk, van R.L.J.; Kuijsters, A.; Dijkstra, K.I.; IJsselsteijn, W.A.

    2010-01-01

    Gaze awareness and eye contact serve important functions in social interaction. In order to maintain those functions in 2D and 3D videoconferencing systems, human sensitivity to eye contact and gaze direction needs to be taken into account in the design of such systems. Here we experimentally

  20. Effects of eye contact and iconic gestures on message retention in human-robot interaction

    NARCIS (Netherlands)

    Dijk, van E.T.; Torta, E.; Cuijpers, R.H.

    2013-01-01

    The effects of iconic gestures and eye contact on message retention in human-robot interaction were investigated in a series of experiments. A humanoid robot gave short verbal messages to participants, accompanied either by iconic gestures or no gestures while making eye contact with the participant

  1. High-speed adaptive optics line scan confocal retinal imaging for human eye.

    Science.gov (United States)

    Lu, Jing; Gu, Boyu; Wang, Xiaolin; Zhang, Yuhua

    2017-01-01

    Continuous and rapid eye movement causes significant intraframe distortion in adaptive optics high resolution retinal imaging. To minimize this artifact, we developed a high speed adaptive optics line scan confocal retinal imaging system. A high speed line camera was employed to acquire retinal image and custom adaptive optics was developed to compensate the wave aberration of the human eye's optics. The spatial resolution and signal to noise ratio were assessed in model eye and in living human eye. The improvement of imaging fidelity was estimated by reduction of intra-frame distortion of retinal images acquired in the living human eyes with frame rates at 30 frames/second (FPS), 100 FPS, and 200 FPS. The device produced retinal image with cellular level resolution at 200 FPS with a digitization of 512×512 pixels/frame in the living human eye. Cone photoreceptors in the central fovea and rod photoreceptors near the fovea were resolved in three human subjects in normal chorioretinal health. Compared with retinal images acquired at 30 FPS, the intra-frame distortion in images taken at 200 FPS was reduced by 50.9% to 79.7%. We demonstrated the feasibility of acquiring high resolution retinal images in the living human eye at a speed that minimizes retinal motion artifact. This device may facilitate research involving subjects with nystagmus or unsteady fixation due to central vision loss.

  2. Imaging shear stress distribution and evaluating the stress concentration factor of the human eye

    Science.gov (United States)

    Joseph Antony, S.

    2015-03-01

    Healthy eyes are vital for a better quality of human life. Historically, for man-made materials, scientists and engineers use stress concentration factors to characterise the effects of structural non-homogeneities on their mechanical strength. However, such information is scarce for the human eye. Here we present the shear stress distribution profiles of a healthy human cornea surface in vivo using photo-stress analysis tomography, which is a non-intrusive and non-X-ray based method. The corneal birefringent retardation measured here is comparable to that of previous studies. Using this, we derive eye stress concentration factors and the directional alignment of major principal stress on the surface of the cornea. Similar to thermometers being used for monitoring the general health in humans, this report provides a foundation to characterise the shear stress carrying capacity of the cornea, and a potential bench mark for validating theoretical modelling of stresses in the human eye in future.

  3. Vergence-mediated changes in the axis of eye rotation during the human vestibulo-ocular reflex can occur independent of eye position.

    Science.gov (United States)

    Migliaccio, Americo A; Cremer, Phillip D; Aw, Swee T; Halmagyi, G Michael; Curthoys, Ian S; Minor, Lloyd B; Todd, Michael J

    2003-07-01

    The aim of this study was to determine whether vergence-mediated changes in the axis of eye rotation in the human vestibulo-ocular reflex (VOR) would obey Listing's Law (normally associated with saccadic eye movements) independent of the initial eye position. We devised a paradigm for disassociating the saccadic velocity axis from eye position by presenting near and far targets that were centered with respect to one eye. We measured binocular 3-dimensional eye movements using search coils in ten normal subjects and 3-dimensional linear head acceleration using Optotrak in seven normal subjects. The stimuli consisted of passive, unpredictable, pitch head rotations with peak acceleration of approximately 2000 degrees /s(2 )and amplitude of approximately 20 degrees. During the pitch head rotation, each subject fixated straight ahead with one eye, whereas the other eye was adducted 4 degrees during far viewing (94 cm) and 25 degrees during near viewing (15 cm). Our data showed expected compensatory pitch rotations in both eyes, and a vergence-mediated horizontal rotation only in the adducting eye. In addition, during near viewing we observed torsional eye rotations not only in the adducting eye but also in the eye looking straight ahead. In the straight-ahead eye, the change in torsional eye velocity between near and far viewing, which began approximately 40 ms after the start of head rotation, was 10+/-6 degrees /s (mean +/- SD). This change in torsional eye velocity resulted in a 2.4+/-1.5 degrees axis tilt toward Listing's plane in that eye. In the adducting eye, the change in torsional eye velocity between near and far viewing was 16+/-6 degrees /s (mean +/- SD) and resulted in a 4.1+/-1.4 degrees axis tilt. The torsional eye velocities were conjugate and both eyes partially obeyed Listing's Law. The axis of eye rotation tilted in the direction of the line of sight by approximately one-third of the angle between the line of sight and a line orthogonal to Listing

  4. EyeFrame: Real-time memory aid improves human multitasking via domain-general eye tracking procedures

    Directory of Open Access Journals (Sweden)

    P. eTaylor

    2015-09-01

    Full Text Available OBJECTIVE: We developed an extensively general closed-loop system to improve human interaction in various multitasking scenarios, with semi-autonomous agents, processes, and robots. BACKGROUND: Much technology is converging toward semi-independent processes with intermittent human supervision distributed over multiple computerized agents. Human operators multitask notoriously poorly, in part due to cognitive load and limited working memory. To multitask optimally, users must remember task order, e.g., the most neglected task, since longer times not monitoring an element indicates greater probability of need for user input. The secondary task of monitoring attention history over multiple spatial tasks requires similar cognitive resources as primary tasks themselves. Humans can not reliably make more than ~2 decisions/s. METHODS: Participants managed a range of 4-10 semi-autonomous agents performing rescue tasks. To optimize monitoring and controlling multiple agents, we created an automated short term memory aid, providing visual cues from users' gaze history. Cues indicated when and where to look next, and were derived from an inverse of eye fixation recency. RESULTS: Contingent eye tracking algorithms drastically improved operator performance, increasing multitasking capacity. The gaze aid reduced biases, and reduced cognitive load, measured by smaller pupil dilation. CONCLUSIONS: Our eye aid likely helped by delegating short-term memory to the computer, and by reducing decision making load. Past studies used eye position for gaze-aware control and interactive updating of displays in application-specific scenarios, but ours is the first to successfully implement domain-general algorithms. Procedures should generalize well to: process control, factory operations, robot control, surveillance, aviation, air traffic control, driving, military, mobile search and rescue, and many tasks where probability of utility is predicted by duration since last

  5. Relationship between eye dominance and pattern electroretinograms in normal human subjects.

    Science.gov (United States)

    Kamis, Umit; Gunduz, Kemal; Okudan, Nilsel; Gokbel, Hakki; Bodur, Sait; Tan, Uner

    2005-02-01

    The authors conducted a study in 100 non-smoker healthy normal human subjects to find a relationship between eye dominance and macular function as tested by using transient stimulus and electroretinography. Eye preference procedure was carried out using two reference points and pattern electroretinograms (PERGs) were recorded using black and white checks, each check subtending 23'. Trace averager was retriggered every 300 milliseconds (ms) with data collection time of 150 ms. The difference in PERG P50 amplitudes between right and left eyes was analyzed using Student's t test. There was no significant difference in PERG P50 amplitudes between the right and left eye dominant subjects as well as no significant differences between the right and left eyes in right eye dominants and left eye dominants, but in the left-eye dominant group the left eye PERG P50 amplitudes were significantly higher in females than males. Although pattern-reversal visual evoked potentials of healthy subjects provide electrophysiological evidence of lateralization in the nervous system, sensory eye dominance seems to have no correlation with macular function.

  6. Proton absorbed dose distribution in human eye simulated by SRNA-2KG code

    International Nuclear Information System (INIS)

    Ilic, R. D.; Pavlovic, R.

    2004-01-01

    The model of Monte Carlo SRNA code is described together with some numerical experiments to show feasibility of this code to be used in proton therapy, especially for tree dimensional proton absorption dose calculation in human eye. (author) [sr

  7. Retinal images in the human eye with implanted intraocular lens

    Science.gov (United States)

    Zając, Marek; Siedlecki, Damian; Nowak, Jerzy

    2007-04-01

    A typical proceeding in cataract is based on the removal of opaque crystalline lens and inserting in its place the artificial intraocular lens (IOL). The quality of retinal image after such procedure depends, among others, on the parameters of the IOL, so the design of the implanted lens is of great importance. An appropriate choice of the IOL material, especially in relation to its biocompatibility, is often considered. However the parameter, which is often omitted during the IOL design is its chromatic aberration. In particular lack of its adequacy to the chromatic aberration of a crystalline lens may cause problems. In order to fit better chromatic aberration of the eye with implanted IOL to that of the healthy eye we propose a hybrid - refractive-diffractive IOL. It can be designed in such way that the total longitudinal chromatic aberration of an eye with implanted IOL equals the total longitudinal chromatic aberration of a healthy eye. In this study we compare the retinal image quality calculated numerically on the basis of the well known Liou-Brennan eye model with typical IOL implanted with that obtained if the IOL is done as hybrid (refractive-diffractive) design.

  8. Pharmacokinetics of bevacizumab after topical and intravitreal administration in human eyes

    OpenAIRE

    Moisseiev, Elad; Waisbourd, Michael; Ben-Artsi, Elad; Levinger, Eliya; Barak, Adiel; Daniels, Tad; Csaky, Karl; Loewenstein, Anat; Barequet, Irina S.

    2013-01-01

    Background Topical bevacizumab is a potential treatment modality for corneal neovascularization, and several recent studies have demonstrated its efficacy. No previous study of the pharmacokinetics of topical bevacizumab has been performed in human eyes. The purpose of this study is to investigate the pharmacokinetics of topical administration of bevacizumab in human eyes, and also to compare the pharmacokinetics of intravitreal bevacizumab injections with previously reported data. Methods Tw...

  9. The Optical Design of the Human Eye: a Critical Review

    Directory of Open Access Journals (Sweden)

    Rafael Navarro

    2009-01-01

    Full Text Available Cornea, lens and eye models are analyzed and compared to experimental findings to assess properties and eventually unveil optical design principles involved in the structure and function of the optical system of the eye. Models and data often show good match but also some paradoxes. The optical design seems to correspond to a wide angle lens. Compared to conventional optical systems, the eye presents a poor optical quality on axis, but a relatively good quality off-axis, thus yielding higher homogeneity for a wide visual field. This seems the result of an intriguing combination of the symmetry design principle with a total lack of rotational symmetry, decentrations and misalignments of the optical surfaces.

  10. A computational model of blast loading on the human eye.

    Science.gov (United States)

    Bhardwaj, Rajneesh; Ziegler, Kimberly; Seo, Jung Hee; Ramesh, K T; Nguyen, Thao D

    2014-01-01

    Ocular injuries from blast have increased in recent wars, but the injury mechanism associated with the primary blast wave is unknown. We employ a three-dimensional fluid-structure interaction computational model to understand the stresses and deformations incurred by the globe due to blast overpressure. Our numerical results demonstrate that the blast wave reflections off the facial features around the eye increase the pressure loading on and around the eye. The blast wave produces asymmetric loading on the eye, which causes globe distortion. The deformation response of the globe under blast loading was evaluated, and regions of high stresses and strains inside the globe were identified. Our numerical results show that the blast loading results in globe distortion and large deviatoric stresses in the sclera. These large deviatoric stresses may be indicator for the risk of interfacial failure between the tissues of the sclera and the orbit.

  11. A new human eye model for ophthalmic brachytherapy dosimetry

    International Nuclear Information System (INIS)

    Yoriyaz, H.; Sanchez, A.; Dos Santos, A.

    2005-01-01

    The present work proposes a new mathematical eye model for ophthalmic brachytherapy dosimetry. This new model includes detailed description of internal structures that were not treated in previous works, allowing dose determination in different regions of the eye for a more adequate clinical analysis. Dose calculations were determined with the MCNP-4C Monte Carlo particle transport code running n parallel environment using PVM. The Amersham CKA4 ophthalmic applicator has been chosen and the depth dose distribution has been determined and compared to those provide by the manufacturer. The results have shown excellent agreement. Besides, absorbed dose values due to both 125 I seeds and 60 Co plaques were obtained for each one of the different structures which compose the eye model and can give relevant information in eventual clinical analyses. (authors)

  12. Association of Bruch's membrane opening and optic disc morphology to axial length and visual field defects in eyes with primary open-angle glaucoma.

    Science.gov (United States)

    Nakanishi, Hideo; Suda, Kenji; Yoshikawa, Munemitsu; Akagi, Tadamichi; Kameda, Takanori; Ikeda, Hanako Ohashi; Yokota, Satoshi; Kurimoto, Yasuo; Tsujikawa, Akitaka

    2018-03-01

    To examine the morphology of Bruch's membrane opening (BMO), optic disc, and peripapillary atrophy (PPA) by scanning laser ophthalmoscopy (SLO) and spectral-domain optical coherence tomography (SD-OCT), and to determine their association with the axial length and visual field defects. This was a cross-sectional study of 94 eyes of 56 subjects; 77 eyes were diagnosed with primary open-angle glaucoma and 17 eyes as normal. The margins of the optic disc were determined in the SLO images, and that of the BMO in the SD-OCT images. The ovality and area of the BMO and the optic disc were measured. The beta and gamma-PPA areas were also measured. The association of each parameter with the axial length and the mean deviation (MD) of the visual field tests was determined by generalized estimating equations (GEEs). The optic disc ovality was associated with the axial length and the MD (β = -0.47, P = 7.6 × 10 -4 and β = 0.12, P = 0.040). The BMO ovality was not significantly associated with the axial length and the MD. The BMO area was associated with the axial length (β = 0.30, P = 0.029). A larger BMO area was associated with a thinner BMO-based neuroretinal rim width (BMO-MRW) after adjustments for the MD (β = -0.30, P = 2.1 × 10 -4 ). The beta- and gamma-PPA areas were associated with the axial length (β = 0.50, P = 7.4 × 10 -5 and β = 0.62, P = 4.2 × 10 -6 ). The optic disc ovality was associated with both the axial length and MD, whereas BMO ovality was not. Attention should be paid to the influence of the axial length-related enlargement of the BMO.

  13. Dating the time of birth: A radiocarbon calibration curve for human eye-lens crystallines

    Energy Technology Data Exchange (ETDEWEB)

    Kjeldsen, Henrik, E-mail: kjeldsen@phys.au.d [AMS 14C Dating Centre, Department of Physics and Astronomy, University of Aarhus, Aarhus (Denmark); Heinemeier, Jan [AMS 14C Dating Centre, Department of Physics and Astronomy, University of Aarhus, Aarhus (Denmark); Heegaard, Steffen [Eye Pathology Section, Department of Neuroscience and Pharmacology, University of Copenhagen, Copenhagen (Denmark); Jacobsen, Christina; Lynnerup, Niels [Department of Forensic Medicine, University of Copenhagen, Copenhagen (Denmark)

    2010-04-15

    Radiocarbon bomb-pulse dating has been used to measure the formation age of human eye-lens crystallines. Lens crystallines are special proteins in the eye-lens that consist of virtually inert tissue. The experimental data show that the radiocarbon ages to a large extent reflect the time of birth, in accordance with expectations. Moreover, it has been possible to develop an age model for the formation of the eye-lens crystallines. From this model a radiocarbon calibration curve for lens crystallines has been calculated. As a consequence, the time of birth of humans can be determined with an accuracy of a few years by radiocarbon dating.

  14. Dating the time of birth: A radiocarbon calibration curve for human eye-lens crystallines

    International Nuclear Information System (INIS)

    Kjeldsen, Henrik; Heinemeier, Jan; Heegaard, Steffen; Jacobsen, Christina; Lynnerup, Niels

    2010-01-01

    Radiocarbon bomb-pulse dating has been used to measure the formation age of human eye-lens crystallines. Lens crystallines are special proteins in the eye-lens that consist of virtually inert tissue. The experimental data show that the radiocarbon ages to a large extent reflect the time of birth, in accordance with expectations. Moreover, it has been possible to develop an age model for the formation of the eye-lens crystallines. From this model a radiocarbon calibration curve for lens crystallines has been calculated. As a consequence, the time of birth of humans can be determined with an accuracy of a few years by radiocarbon dating.

  15. Measuring Human Performance in Simulated Nuclear Power Plant Control Rooms Using Eye Tracking

    Energy Technology Data Exchange (ETDEWEB)

    Kovesdi, Casey Robert [Idaho National Lab. (INL), Idaho Falls, ID (United States); Rice, Brandon Charles [Idaho National Lab. (INL), Idaho Falls, ID (United States); Bower, Gordon Ross [Idaho National Lab. (INL), Idaho Falls, ID (United States); Spielman, Zachary Alexander [Idaho National Lab. (INL), Idaho Falls, ID (United States); Hill, Rachael Ann [Idaho National Lab. (INL), Idaho Falls, ID (United States); LeBlanc, Katya Lee [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-11-01

    Control room modernization will be an important part of life extension for the existing light water reactor fleet. As part of modernization efforts, personnel will need to gain a full understanding of how control room technologies affect performance of human operators. Recent advances in technology enables the use of eye tracking technology to continuously measure an operator’s eye movement, which correlates with a variety of human performance constructs such as situation awareness and workload. This report describes eye tracking metrics in the context of how they will be used in nuclear power plant control room simulator studies.

  16. Measuring Human Performance in Simulated Nuclear Power Plant Control Rooms Using Eye Tracking

    International Nuclear Information System (INIS)

    Kovesdi, Casey Robert; Rice, Brandon Charles; Bower, Gordon Ross; Spielman, Zachary Alexander; Hill, Rachael Ann; LeBlanc, Katya Lee

    2015-01-01

    Control room modernization will be an important part of life extension for the existing light water reactor fleet. As part of modernization efforts, personnel will need to gain a full understanding of how control room technologies affect performance of human operators. Recent advances in technology enables the use of eye tracking technology to continuously measure an operator's eye movement, which correlates with a variety of human performance constructs such as situation awareness and workload. This report describes eye tracking metrics in the context of how they will be used in nuclear power plant control room simulator studies.

  17. Dynamical models of the human eye and strabismus

    International Nuclear Information System (INIS)

    Pascolo, P.; Carniel, R.; Grimaz, S.

    2009-01-01

    In this work, the applicability of a recently published dynamical model of the eye to the case of strabismus is investigated. Although the basic scheme of the original model remains valid, the simulation of the pathological dynamics requires a more suitable coverage of the space of the physiological rotations of the eye. This requisite is reached by developing the original model and by taking into account the contributions of connective tissues that were originally neglected. Possible wider fields of application of the model are then discussed.

  18. History-dependence of muscle slack length following contraction and stretch in the human vastus lateralis.

    Science.gov (United States)

    Stubbs, Peter W; Walsh, Lee D; D'Souza, Arkiev; Héroux, Martin E; Bolsterlee, Bart; Gandevia, Simon C; Herbert, Robert D

    2018-06-01

    In reduced muscle preparations, the slack length and passive stiffness of muscle fibres have been shown to be influenced by previous muscle contraction or stretch. In human muscles, such behaviours have been inferred from measures of muscle force, joint stiffness and reflex magnitudes and latencies. Using ultrasound imaging, we directly observed that isometric contraction of the vastus lateralis muscle at short lengths reduces the slack lengths of the muscle-tendon unit and muscle fascicles. The effect is apparent 60 s after the contraction. These observations imply that muscle contraction at short lengths causes the formation of bonds which reduce the effective length of structures that generate passive tension in muscles. In reduced muscle preparations, stretch and muscle contraction change the properties of relaxed muscle fibres. In humans, effects of stretch and contraction on properties of relaxed muscles have been inferred from measurements of time taken to develop force, joint stiffness and reflex latencies. The current study used ultrasound imaging to directly observe the effects of stretch and contraction on muscle-tendon slack length and fascicle slack length of the human vastus lateralis muscle in vivo. The muscle was conditioned by (a) strong isometric contractions at long muscle-tendon lengths, (b) strong isometric contractions at short muscle-tendon lengths, (c) weak isometric contractions at long muscle-tendon lengths and (d) slow stretches. One minute after conditioning, ultrasound images were acquired from the relaxed muscle as it was slowly lengthened through its physiological range. The ultrasound image sequences were used to identify muscle-tendon slack angles and fascicle slack lengths. Contraction at short muscle-tendon lengths caused a mean 13.5 degree (95% CI 11.8-15.0 degree) shift in the muscle-tendon slack angle towards shorter muscle-tendon lengths, and a mean 5 mm (95% CI 2-8 mm) reduction in fascicle slack length, compared to the

  19. Human Commercial Models' Eye Colour Shows Negative Frequency-Dependent Selection.

    Directory of Open Access Journals (Sweden)

    Isabela Rodrigues Nogueira Forti

    Full Text Available In this study we investigated the eye colour of human commercial models registered in the UK (400 female and 400 male and Brazil (400 female and 400 male to test the hypothesis that model eye colour frequency was the result of negative frequency-dependent selection. The eye colours of the models were classified as: blue, brown or intermediate. Chi-square analyses of data for countries separated by sex showed that in the United Kingdom brown eyes and intermediate colours were significantly more frequent than expected in comparison to the general United Kingdom population (P<0.001. In Brazil, the most frequent eye colour brown was significantly less frequent than expected in comparison to the general Brazilian population. These results support the hypothesis that model eye colour is the result of negative frequency-dependent selection. This could be the result of people using eye colour as a marker of genetic diversity and finding rarer eye colours more attractive because of the potential advantage more genetically diverse offspring that could result from such a choice. Eye colour may be important because in comparison to many other physical traits (e.g., hair colour it is hard to modify, hide or disguise, and it is highly polymorphic.

  20. Eye Detection and Tracking for Intelligent Human Computer Interaction

    National Research Council Canada - National Science Library

    Yin, Lijun

    2006-01-01

    .... In this project, Dr. Lijun Yin has developed a new algorithm for detecting and tracking eyes under an unconstrained environment using a single ordinary camera or webcam. The new algorithm is advantageous in that it works in a non-intrusive way based on a socalled Topographic Context approach.

  1. Objective measurement of postocclusion surge during phacoemulsification in human eye-bank eyes.

    Science.gov (United States)

    Georgescu, Dan; Payne, Marielle; Olson, Randall J

    2007-03-01

    To objectively compare the postocclusion vacuum surge among different phacoemulsification machines and devices. Experimental study. Infiniti, Legacy, Millennium, and Sovereign were tested in an eye-bank eye. All the machines were tested with 20-gauge non-ABS tips, 430 mm Hg vacuum pressure, 24 ml/minute aspiration rate, peristaltic pump, and 75 cm bottle height. In addition, Infiniti and Legacy were also tested with 20-gauge bypass tips (ABS), 125 cm bottle height, and 40 ml/minute flow rate. We also tested 19-gauge tips with Infiniti and Sovereign and the venturi pump for Millennium. Significant differences were found between all the machines tested with Millennium peristaltic generating the least and Millennium Venturi the most surge. ABS tips significantly decreased the surge for Legacy but not for Infiniti. Cruise Control (CC) had a significant effect on Sovereign but not on Millennium. Increasing the bottle height decreased surge while increasing the flow increased surge for both Infiniti and Legacy. The 19-gauge tips increased surge for both Infiniti and Sovereign. Surge varied over a range of 40 microm to more than 2 mm. ABS and CC decrease surge, especially when the machine is not functioning near the limits of surge prevention. Certain parameters, such as a 19-gauge tip and high flow, dramatically increased surge, whereas elevating the bottle ameliorates it. Understanding the impact of all these features will help in minimizing the problem.

  2. Image system analysis of human eye wave-front aberration on the basis of HSS

    Science.gov (United States)

    Xu, Ancheng

    2017-07-01

    Hartmann-Shack sensor (HSS) has been used in objective measurement of human eye wave-front aberration, but the research on the effects of sampling point size on the accuracy of the result has not been reported. In this paper, point spread function (PSF) of the whole system mathematical model was obtained via measuring the optical imaging system structure of human eye wave-front aberration measurement. The impact of Airy spot size on the accuracy of system was analyzed. Statistics study show that the geometry of Airy spot size of the ideal light source sent from eye retina formed on the surface of HSS is far smaller than the size of the HSS sample point image used in the experiment. Therefore, the effect of Airy spot on the precision of the system can be ignored. This study theoretically and experimentally justifies the reliability and accuracy of human eye wave-front aberration measurement based on HSS.

  3. Multiconjugate adaptive optics applied to an anatomically accurate human eye model.

    Science.gov (United States)

    Bedggood, P A; Ashman, R; Smith, G; Metha, A B

    2006-09-04

    Aberrations of both astronomical telescopes and the human eye can be successfully corrected with conventional adaptive optics. This produces diffraction-limited imagery over a limited field of view called the isoplanatic patch. A new technique, known as multiconjugate adaptive optics, has been developed recently in astronomy to increase the size of this patch. The key is to model atmospheric turbulence as several flat, discrete layers. A human eye, however, has several curved, aspheric surfaces and a gradient index lens, complicating the task of correcting aberrations over a wide field of view. Here we utilize a computer model to determine the degree to which this technology may be applied to generate high resolution, wide-field retinal images, and discuss the considerations necessary for optimal use with the eye. The Liou and Brennan schematic eye simulates the aspheric surfaces and gradient index lens of real human eyes. We show that the size of the isoplanatic patch of the human eye is significantly increased through multiconjugate adaptive optics.

  4. Multiconjugate adaptive optics applied to an anatomically accurate human eye model

    Science.gov (United States)

    Bedggood, P. A.; Ashman, R.; Smith, G.; Metha, A. B.

    2006-09-01

    Aberrations of both astronomical telescopes and the human eye can be successfully corrected with conventional adaptive optics. This produces diffraction-limited imagery over a limited field of view called the isoplanatic patch. A new technique, known as multiconjugate adaptive optics, has been developed recently in astronomy to increase the size of this patch. The key is to model atmospheric turbulence as several flat, discrete layers. A human eye, however, has several curved, aspheric surfaces and a gradient index lens, complicating the task of correcting aberrations over a wide field of view. Here we utilize a computer model to determine the degree to which this technology may be applied to generate high resolution, wide-field retinal images, and discuss the considerations necessary for optimal use with the eye. The Liou and Brennan schematic eye simulates the aspheric surfaces and gradient index lens of real human eyes. We show that the size of the isoplanatic patch of the human eye is significantly increased through multiconjugate adaptive optics.

  5. The Human Eye Position Control System in a Rehabilitation Setting

    Directory of Open Access Journals (Sweden)

    Yvonne Nolan

    2005-01-01

    Full Text Available Our work at Ireland’s National Rehabilitation Hospital involves designing communication systems for people suffering from profound physical disabilities. One such system uses the electro-oculogram, which is an (x,y system of voltages picked up by pairs of electrodes placed, respectively, above and below and on either side of the eyes. The eyeball has a dc polarisation between cornea and back, arising from the photoreceptor rods and cones in the retina. As the eye rotates, the varying voltages projected onto the electrodes drive a cursor over a mimic keyboard on a computer screen. Symbols are selected with a switching action derived, for example, from a blink. Experience in using this mode of communication has given us limited facilities to study the eye position control system. We present here a resulting new feedback model for rotation in either the vertical or the horizontal plane, which involves the eyeball controlled by an agonist-antagonist muscle pair, modelled by a single equivalent bidirectional muscle with torque falling off linearly with angular velocity. We have incorporated muscle spindles and have tuned them by pole assignment associated with an optimum stability criterion.

  6. A generalised porous medium approach to study thermo-fluid dynamics in human eyes.

    Science.gov (United States)

    Mauro, Alessandro; Massarotti, Nicola; Salahudeen, Mohamed; Romano, Mario R; Romano, Vito; Nithiarasu, Perumal

    2018-03-22

    The present work describes the application of the generalised porous medium model to study heat and fluid flow in healthy and glaucomatous eyes of different subject specimens, considering the presence of ocular cavities and porous tissues. The 2D computational model, implemented into the open-source software OpenFOAM, has been verified against benchmark data for mixed convection in domains partially filled with a porous medium. The verified model has been employed to simulate the thermo-fluid dynamic phenomena occurring in the anterior section of four patient-specific human eyes, considering the presence of anterior chamber (AC), trabecular meshwork (TM), Schlemm's canal (SC), and collector channels (CC). The computational domains of the eye are extracted from tomographic images. The dependence of TM porosity and permeability on intraocular pressure (IOP) has been analysed in detail, and the differences between healthy and glaucomatous eye conditions have been highlighted, proving that the different physiological conditions of patients have a significant influence on the thermo-fluid dynamic phenomena. The influence of different eye positions (supine and standing) on thermo-fluid dynamic variables has been also investigated: results are presented in terms of velocity, pressure, temperature, friction coefficient and local Nusselt number. The results clearly indicate that porosity and permeability of TM are two important parameters that affect eye pressure distribution. Graphical abstract Velocity contours and vectors for healthy eyes (top) and glaucomatous eyes (bottom) for standing position.

  7. Early visual evoked potentials are modulated by eye position in humans induced by whole body rotations

    Directory of Open Access Journals (Sweden)

    Petit Laurent

    2004-09-01

    Full Text Available Abstract Background To reach and grasp an object in space on the basis of its image cast on the retina requires different coordinate transformations that take into account gaze and limb positioning. Eye position in the orbit influences the image's conversion from retinotopic (eye-centered coordinates to an egocentric frame necessary for guiding action. Neuroimaging studies have revealed eye position-dependent activity in extrastriate visual, parietal and frontal areas that is along the visuo-motor pathway. At the earliest vision stage, the role of the primary visual area (V1 in this process remains unclear. We used an experimental design based on pattern-onset visual evoked potentials (VEP recordings to study the effect of eye position on V1 activity in humans. Results We showed that the amplitude of the initial C1 component of VEP, acknowledged to originate in V1, was modulated by the eye position. We also established that putative spontaneous small saccades related to eccentric fixation, as well as retinal disparity cannot explain the effects of changing C1 amplitude of VEP in the present study. Conclusions The present modulation of the early component of VEP suggests an eye position-dependent activity of the human primary visual area. Our findings also evidence that cortical processes combine information about the position of the stimulus on the retinae with information about the location of the eyes in their orbit as early as the stage of primary visual area.

  8. Comparative Analysis of Human and Canine Campylobacter upsaliensis Isolates by Amplified Fragment Length Polymorphism

    DEFF Research Database (Denmark)

    Damborg, Peter; Guardabassi, Luca; Pedersen, Karl

    2008-01-01

    Human (n = 33) and canine (n = 53) Campylobacter upsaliensis isolates from seven countries were genotyped by a new amplified fragment length polymorphism method. We observed 100% typeability and high overall diversity. The majority of human strains (23/33) clustered separately from canine strains...

  9. Effects of intraocular lenses with different diopters on chromatic aberrations in human eye models

    OpenAIRE

    Song, Hui; Yuan, Xiaoyong; Tang, Xin

    2016-01-01

    Background In this study, the effects of intraocular lenses (IOLs) with different diopters (D) on chromatic aberration were investigated in human eye models, and the influences of the central thickness of IOLs on chromatic aberration were compared. Methods A Liou-Brennan-based IOL eye model was constructed using ZEMAX optical design software. Spherical IOLs with different diopters (AR40e, AMO Company, USA) were implanted; modulation transfer function (MTF) values at 3?mm of pupil diameter and...

  10. A comparative study of complications of cataract surgery with phacoemulsification in eyes with high and normal axial length

    Directory of Open Access Journals (Sweden)

    Hamid Fesharaki

    2012-01-01

    Conclusions: As the results illustrate, in this survey, age and high axial length were statistically significant risk factors for incidence of intraoperative complications of cataract surgery with phacoemulsification technique. Anticipation of these complications and also preparation and prophylactic measures may decrease incidence of these complications.

  11. Human eye analytical and mesh-geometry models for ophthalmic dosimetry using MCNP6

    International Nuclear Information System (INIS)

    Angelocci, Lucas V.; Fonseca, Gabriel P.; Yoriyaz, Helio

    2015-01-01

    Eye tumors can be treated with brachytherapy using Co-60 plaques, I-125 seeds, among others materials. The human eye has regions particularly vulnerable to ionizing radiation (e.g. crystalline) and dosimetry for this region must be taken carefully. A mathematical model was proposed in the past [1] for the eye anatomy to be used in Monte Carlo simulations to account for dose distribution in ophthalmic brachytherapy. The model includes the description for internal structures of the eye that were not treated in previous works. The aim of this present work was to develop a new eye model based on the Mesh geometries of the MCNP6 code. The methodology utilized the ABAQUS/CAE (Simulia 3DS) software to build the Mesh geometry. For this work, an ophthalmic applicator containing up to 24 model Amersham 6711 I-125 seeds (Oncoseed) was used, positioned in contact with a generic tumor defined analytically inside the eye. The absorbed dose in eye structures like cornea, sclera, choroid, retina, vitreous body, lens, optical nerve and optical nerve wall were calculated using both models: analytical and MESH. (author)

  12. Human eye analytical and mesh-geometry models for ophthalmic dosimetry using MCNP6

    Energy Technology Data Exchange (ETDEWEB)

    Angelocci, Lucas V.; Fonseca, Gabriel P.; Yoriyaz, Helio, E-mail: hyoriyaz@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Eye tumors can be treated with brachytherapy using Co-60 plaques, I-125 seeds, among others materials. The human eye has regions particularly vulnerable to ionizing radiation (e.g. crystalline) and dosimetry for this region must be taken carefully. A mathematical model was proposed in the past [1] for the eye anatomy to be used in Monte Carlo simulations to account for dose distribution in ophthalmic brachytherapy. The model includes the description for internal structures of the eye that were not treated in previous works. The aim of this present work was to develop a new eye model based on the Mesh geometries of the MCNP6 code. The methodology utilized the ABAQUS/CAE (Simulia 3DS) software to build the Mesh geometry. For this work, an ophthalmic applicator containing up to 24 model Amersham 6711 I-125 seeds (Oncoseed) was used, positioned in contact with a generic tumor defined analytically inside the eye. The absorbed dose in eye structures like cornea, sclera, choroid, retina, vitreous body, lens, optical nerve and optical nerve wall were calculated using both models: analytical and MESH. (author)

  13. See You See Me: the Role of Eye Contact in Multimodal Human-Robot Interaction.

    Science.gov (United States)

    Xu, Tian Linger; Zhang, Hui; Yu, Chen

    2016-05-01

    We focus on a fundamental looking behavior in human-robot interactions - gazing at each other's face. Eye contact and mutual gaze between two social partners are critical in smooth human-human interactions. Therefore, investigating at what moments and in what ways a robot should look at a human user's face as a response to the human's gaze behavior is an important topic. Toward this goal, we developed a gaze-contingent human-robot interaction system, which relied on momentary gaze behaviors from a human user to control an interacting robot in real time. Using this system, we conducted an experiment in which human participants interacted with the robot in a joint attention task. In the experiment, we systematically manipulated the robot's gaze toward the human partner's face in real time and then analyzed the human's gaze behavior as a response to the robot's gaze behavior. We found that more face looks from the robot led to more look-backs (to the robot's face) from human participants and consequently created more mutual gaze and eye contact between the two. Moreover, participants demonstrated more coordinated and synchronized multimodal behaviors between speech and gaze when more eye contact was successfully established and maintained.

  14. A Proactive Approach of Robotic Framework for Making Eye Contact with Humans

    Directory of Open Access Journals (Sweden)

    Mohammed Moshiul Hoque

    2014-01-01

    Full Text Available Making eye contact is a most important prerequisite function of humans to initiate a conversation with others. However, it is not an easy task for a robot to make eye contact with a human if they are not facing each other initially or the human is intensely engaged his/her task. If the robot would like to start communication with a particular person, it should turn its gaze to that person and make eye contact with him/her. However, such a turning action alone is not enough to set up an eye contact phenomenon in all cases. Therefore, the robot should perform some stronger actions in some situations so that it can attract the target person before meeting his/her gaze. In this paper, we proposed a conceptual model of eye contact for social robots consisting of two phases: capturing attention and ensuring the attention capture. Evaluation experiments with human participants reveal the effectiveness of the proposed model in four viewing situations, namely, central field of view, near peripheral field of view, far peripheral field of view, and out of field of view.

  15. Goat′s eye integrated with a human cataractous lens: A training model for phacoemulsification

    Directory of Open Access Journals (Sweden)

    Sabyasachi Sengupta

    2015-01-01

    Full Text Available A relatively simple and inexpensive technique to train surgeons in phacoemulsification using a goat′s eye integrated with a human cataractous nucleus is described. The goat′s eye is placed on a bed of cotton within the lumen of a cylindrical container. This is then mounted on a rectangular thermocol so that the limbus is presented at the surgical field. After making a clear corneal entry with a keratome, the trainer makes a 5-5.5 mm continuous curvilinear capsulorhexis in the anterior lens capsule, creates a crater of adequate depth in the cortex and inserts the human nucleus within this crater in the goat′s capsular bag. The surgical wound is sutured, and the goat′s eye is ready for training. Creating the capsulorhexis with precision and making the crater of adequate depth to snugly accommodate the human nucleus are the most important steps to prevent excessive wobbling of the nucleus while training.

  16. Goat's eye integrated with a human cataractous lens: A training model for phacoemulsification.

    Science.gov (United States)

    Sengupta, Sabyasachi; Dhanapal, Praveen; Nath, Manas; Haripriya, Aravind; Venkatesh, Rengaraj

    2015-03-01

    A relatively simple and inexpensive technique to train surgeons in phacoemulsification using a goat's eye integrated with a human cataractous nucleus is described. The goat's eye is placed on a bed of cotton within the lumen of a cylindrical container. This is then mounted on a rectangular thermocol so that the limbus is presented at the surgical field. After making a clear corneal entry with a keratome, the trainer makes a 5-5.5 mm continuous curvilinear capsulorhexis in the anterior lens capsule, creates a crater of adequate depth in the cortex and inserts the human nucleus within this crater in the goat's capsular bag. The surgical wound is sutured, and the goat's eye is ready for training. Creating the capsulorhexis with precision and making the crater of adequate depth to snugly accommodate the human nucleus are the most important steps to prevent excessive wobbling of the nucleus while training.

  17. Dosimetric Comparison of Simulated Human Eye And Water Phantom in Investigation of Iodine Source Effects on Tumour And Healthy Tissues

    International Nuclear Information System (INIS)

    Sadi, A.S.; Masoudi, F.S. K.N.Toosi University of Technology

    2011-01-01

    For better clinical analysis in ophthalmic brachytherapy dosimetry, there is a need for the dose determination in different parts of the eye, so simulating the eye and defining the material of any parts of that, is helpful for better investigating dosimetry in human eye. However in brachytherapy dosimetry, it is common to consider the water phantom as human eye globe. In this work, a full human eye is simulated with MCNP-4C code by considering all parts of the eye like; lens, cornea, retina, choroid, sclera, anterior chamber, optic nerve, bulk of the eye comprising vitreous body and tumour. The average dose in different parts of this full model of human eye is determined and the results are compared with the dose calculated in water phantom. The central axes depth dose and the dose in whole of the tumour for these two simulated eye model are calculated too, and the results are compared. At long last, as the aim of this work is comparing the result of investigating dosimetry between two water phantom as human eye and simulated eye globe, the ratios of the absorbed dose by the healthy tissues to the absorbed dose by the tumour are calculated in these simulations and the comparison between results is done eventually.

  18. Geometrical theory to predict eccentric photorefraction intensity profiles in the human eye

    Science.gov (United States)

    Roorda, Austin; Campbell, Melanie C. W.; Bobier, W. R.

    1995-08-01

    In eccentric photorefraction, light returning from the retina of the eye is photographed by a camera focused on the eye's pupil. We use a geometrical model of eccentric photorefraction to generate intensity profiles across the pupil image. The intensity profiles for three different monochromatic aberration functions induced in a single eye are predicted and show good agreement with the measured eccentric photorefraction intensity profiles. A directional reflection from the retina is incorporated into the calculation. Intensity profiles for symmetric and asymmetric aberrations are generated and measured. The latter profile shows a dependency on the source position and the meridian. The magnitude of the effect of thresholding on measured pattern extents is predicted. Monochromatic aberrations in human eyes will cause deviations in the eccentric photorefraction measurements from traditional crescents caused by defocus and may cause misdiagnoses of ametropia or anisometropia. Our results suggest that measuring refraction along the vertical meridian is preferred for screening studies with the eccentric photorefractor.

  19. Importance of non-synonymous OCA2 variants in human eye colour prediction

    DEFF Research Database (Denmark)

    Andersen, Jeppe Dyrberg; Pietroni, Carlotta; Johansen, Peter

    2016-01-01

    in the promotor region of OCA2 (OMIM #611409). Nevertheless, many eye colors cannot be explained by only considering rs12913832:A>G. Methods: In this study, we searched for additional variants in OCA2 to explain human eye color by sequencing a 500 kbp region, encompassing OCA2 and its promotor region. Results: We...... identified three nonsynonymous OCA2 variants as important for eye color, including rs1800407:G>A (p.Arg419Gln) and two variants, rs74653330:A>T (p.Ala481Thr) and rs121918166:G>A (p.Val443Ile), not previously described as important for eye color variation. It was shown that estimated haplotypes consisting...

  20. The length of teeth : A statistical analysis of the differences in length of human teeth for radiologic purposes

    NARCIS (Netherlands)

    Verhoeven, J.W.; Aken, J. van; Weerdt, G.P. van der

    Intraoral radiograms can be made according to the long tube paralleling technique utilizing aiming devices. An important factor in the design of these instruments is the length of the teeth to be radiographed. Reliable data regarding the length of the teeth in the different regions of the mouth are

  1. Towards Quantum Experiments with Human Eye Detectors Based on Cloning via Stimulated Emission ?

    Science.gov (United States)

    De Martini, Francesco

    2010-05-01

    In a recent theoretical paper published in Physical Review Letters, Sekatsky, Brunner, Branciard, Gisin, Simon report an extended investigation on some properties of the human eye that affect its behavior as a quantum detector. We believe that the content of this work, albeit appealing at fist sight, is highly questionable simply because the human eye cannot be adopted as a sensing device within any quantum measurement apparatus. Furthermore, the criticism raised by these Authors against a real experiment on Micro—Macro entanglement recently published in Physical Review Letters (100, 253601, 2008) is found misleading and misses its target.

  2. Statistical characteristics of aberrations of human eyes after small incision lenticule extraction surgery and analysis of visual performance with individual eye model.

    Science.gov (United States)

    Lou, Qiqi; Wang, Yan; Wang, Zhaoqi; Liu, Yongji; Zhang, Lin; Fang, Hui

    2015-09-01

    Preoperative and postoperative wavefront aberrations of 73 myopic eyes with small incision lenticule extraction surgery are analyzed in this paper. Twenty-eight postoperative individual eye models are constructed to investigate the visual acuity (VA) of human eyes. Results show that in photopic condition, residual defocus, residual astigmatism, and higher-order aberrations are relatively small. 100% of eyes reach a VA of 0.8 or better, and 89.3% of eyes reach a VA of 1.0 or better. In scotopic condition, the residual defocus and the higher-order aberrations are, respectively, 1.9 and 8.5 times the amount of that in photopic condition, and the defocus becomes the main factor attenuating visual performance.

  3. APPLICATION OF EYE TRACKING FOR MEASUREMENT AND EVALUATION IN HUMAN FACTORS STUDIES IN CONTROL ROOM MODERNIZATION

    Energy Technology Data Exchange (ETDEWEB)

    Kovesdi, C.; Spielman, Z.; LeBlanc, K.; Rice, B.

    2017-05-01

    An important element of human factors engineering (HFE) pertains to measurement and evaluation (M&E). The role of HFE-M&E should be integrated throughout the entire control room modernization (CRM) process and be used for human-system performance evaluation and diagnostic purposes with resolving potential human engineering deficiencies (HEDs) and other human machine interface (HMI) design issues. NUREG-0711 describes how HFE in CRM should employ a hierarchical set of measures, particularly during integrated system validation (ISV), including plant performance, personnel task performance, situation awareness, cognitive workload, and anthropometric/ physiological factors. Historically, subjective measures have been primarily used since they are easier to collect and do not require specialized equipment. However, there are pitfalls with relying solely on subjective measures in M&E such that negatively impact reliability, sensitivity, and objectivity. As part of comprehensively capturing a diverse set of measures that strengthen findings and inferences made of the benefits from emerging technologies like advanced displays, this paper discusses the value of using eye tracking as an objective method that can be used in M&E. A brief description of eye tracking technology and relevant eye tracking measures is provided. Additionally, technical considerations and the unique challenges with using eye tracking in full-scaled simulations are addressed. Finally, this paper shares preliminary findings regarding the use of a wearable eye tracking system in a full-scale simulator study. These findings should help guide future full-scale simulator studies using eye tracking as a methodology to evaluate human-system performance.

  4. See You See Me: the Role of Eye Contact in Multimodal Human-Robot Interaction

    Science.gov (United States)

    XU, TIAN (LINGER); ZHANG, HUI; YU, CHEN

    2016-01-01

    We focus on a fundamental looking behavior in human-robot interactions – gazing at each other’s face. Eye contact and mutual gaze between two social partners are critical in smooth human-human interactions. Therefore, investigating at what moments and in what ways a robot should look at a human user’s face as a response to the human’s gaze behavior is an important topic. Toward this goal, we developed a gaze-contingent human-robot interaction system, which relied on momentary gaze behaviors from a human user to control an interacting robot in real time. Using this system, we conducted an experiment in which human participants interacted with the robot in a joint attention task. In the experiment, we systematically manipulated the robot’s gaze toward the human partner’s face in real time and then analyzed the human’s gaze behavior as a response to the robot’s gaze behavior. We found that more face looks from the robot led to more look-backs (to the robot’s face) from human participants and consequently created more mutual gaze and eye contact between the two. Moreover, participants demonstrated more coordinated and synchronized multimodal behaviors between speech and gaze when more eye contact was successfully established and maintained. PMID:28966875

  5. Mathematical models of the dynamics of the human eye

    CERN Document Server

    Collins, Richard

    1980-01-01

    A rich and abundant literature has developed during the last half century dealing with mechanical aspects of the eye, mainly from clinical and, experimental points of view. For the most part, workers have attempted to shed light on the complex set of conditions known by the general term glaucoma. These conditions are characterised by an increase in intraocular pressure sufficient to cause de­ generation of the optic disc and concomitant defects in the visual field, which, if not controlled, lead to inevitable permanent blindness. In the United States alone, an estimated 50,000 persons are blind as a result of glaucoma, which strikes about 2% of the population over 40 years of age (Vaughan and Asbury, 1974). An understanding of the underlying mechanisms of glaucoma is hindered by the fact that elevated intraocular pressure, like a runny nose, is but a symptom which may have a variety of causes. Only by turning to the initial pathology can one hope to understand this important class of medical problems.

  6. Dose conversion coefficients for neutron exposure to the lens of the human eye

    International Nuclear Information System (INIS)

    Manger, Ryan P.; Bellamy, Michael B.; Eckerman, Keith F.

    2011-01-01

    Dose conversion coefficients for the lens of the human eye have been calculated for neutron exposure at energies from 1 x 10 -9 to 20 MeV and several standard orientations: anterior-to-posterior, rotational and right lateral. MCNPX version 2.6.0, a Monte Carlo-based particle transport package, was used to determine the energy deposited in the lens of the eye. The human eyeball model was updated by partitioning the lens into sensitive and insensitive volumes as the anterior portion (sensitive volume) of the lens being more radiosensitive and prone to cataract formation. The updated eye model was used with the adult UF-ORNL mathematical phantom in the MCNPX transport calculations.

  7. Dose conversion coefficients for neutron exposure to the lens of the human eye

    International Nuclear Information System (INIS)

    Manger, R. P.; Bellamy, M. B.; Eckerman, K. F.

    2012-01-01

    Dose conversion coefficients for the lens of the human eye have been calculated for neutron exposure at energies from 1 x 10 -9 to 20 MeV and several standard orientations: anterior-to-posterior, rotational and right lateral. MCNPX version 2.6.0, a Monte Carlo-based particle transport package, was used to determine the energy deposited in the lens of the eye. The human eyeball model was updated by partitioning the lens into sensitive and insensitive volumes as the anterior portion (sensitive volume) of the lens being more radiosensitive and prone to cataract formation. The updated eye model was used with the adult UF-ORNL mathematical phantom in the MCNPX transport calculations. (authors)

  8. The effect of human image in B2C website design: an eye-tracking study

    Science.gov (United States)

    Wang, Qiuzhen; Yang, Yi; Wang, Qi; Ma, Qingguo

    2014-09-01

    On B2C shopping websites, effective visual designs can bring about consumers' positive emotional experience. From this perspective, this article developed a research model to explore the impact of human image as a visual element on consumers' online shopping emotions and subsequent attitudes towards websites. This study conducted an eye-tracking experiment to collect both eye movement data and questionnaire data to test the research model. Questionnaire data analysis showed that product pictures combined with human image induced positive emotions among participants, thus promoting their attitudes towards online shopping websites. Specifically, product pictures with human image first produced higher levels of image appeal and perceived social presence, thus stimulating higher levels of enjoyment and subsequent positive attitudes towards the websites. Moreover, a moderating effect of product type was demonstrated on the relationship between the presence of human image and the level of image appeal. Specifically, human image significantly increased the level of image appeal when integrated in entertainment product pictures while this relationship was not significant in terms of utilitarian products. Eye-tracking data analysis further supported these results and provided plausible explanations. The presence of human image significantly increased the pupil size of participants regardless of product types. For entertainment products, participants paid more attention to product pictures integrated with human image whereas for utilitarian products more attention was paid to functional information of products than to product pictures no matter whether or not integrated with human image.

  9. Mechanical model of human eye compliance for volumetric occlusion break surge measurements.

    Science.gov (United States)

    Dyk, David W; Miller, Kevin M

    2018-02-01

    To develop a mechanical model of human eye compliance for volumetric studies. Alcon Research, Ltd., Lake Forest, California, USA. Experimental study. Enucleated human eyes underwent pressurization and depressurization cycles with peak intraocular pressures (IOPs) of 60 to 100 mm Hg; anterior chamber pressure and volume changes were measured. Average net volume change curves were calculated as a function of IOP for each eye. Overall mean volumes were computed from each eye's average results at pressure points extrapolated over the range of 5 to 90 mm Hg. A 2-term exponential function was fit to these results. A fluid chamber with a displaceable piston was created as a mechanical model of this equation. A laser confocal displacement meter was used to measure piston displacement. A test bed incorporated the mechanical model with a mounted phacoemulsification probe and allowed for simulated occlusion breaks. Surge volume was calculated from piston displacement. An exponential function, V = C 1 × exp(C 2 × IOP) + C 3  × exp(C 4  × IOP) - V 0 , where V, the volume, was fit to the final depressurization curve obtained from 15 enucleated human eyes. The C 1 through C 4 values were -0.07141, -0.23055, -0.14972, and -0.02006, respectively. The equation was modeled using a piston system with 3 parallel springs that engaged serially. The mechanical model mimicked depressurization curves observed in human cadaver eyes. The resulting mechanical compliance model measured ocular volumetric changes and thus would be helpful in characterizing the postocclusion break surge response. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. Social interactions through the eyes of macaques and humans.

    Directory of Open Access Journals (Sweden)

    Richard McFarland

    Full Text Available Group-living primates frequently interact with each other to maintain social bonds as well as to compete for valuable resources. Observing such social interactions between group members provides individuals with essential information (e.g. on the fighting ability or altruistic attitude of group companions to guide their social tactics and choice of social partners. This process requires individuals to selectively attend to the most informative content within a social scene. It is unclear how non-human primates allocate attention to social interactions in different contexts, and whether they share similar patterns of social attention to humans. Here we compared the gaze behaviour of rhesus macaques and humans when free-viewing the same set of naturalistic images. The images contained positive or negative social interactions between two conspecifics of different phylogenetic distance from the observer; i.e. affiliation or aggression exchanged by two humans, rhesus macaques, Barbary macaques, baboons or lions. Monkeys directed a variable amount of gaze at the two conspecific individuals in the images according to their roles in the interaction (i.e. giver or receiver of affiliation/aggression. Their gaze distribution to non-conspecific individuals was systematically varied according to the viewed species and the nature of interactions, suggesting a contribution of both prior experience and innate bias in guiding social attention. Furthermore, the monkeys' gaze behavior was qualitatively similar to that of humans, especially when viewing negative interactions. Detailed analysis revealed that both species directed more gaze at the face than the body region when inspecting individuals, and attended more to the body region in negative than in positive social interactions. Our study suggests that monkeys and humans share a similar pattern of role-sensitive, species- and context-dependent social attention, implying a homologous cognitive mechanism of

  11. Comparison of rhythmic masticatory muscle activity during non-rapid eye movement sleep in guinea pigs and humans.

    Science.gov (United States)

    Kato, Takafumi; Toyota, Risa; Haraki, Shingo; Yano, Hiroyuki; Higashiyama, Makoto; Ueno, Yoshio; Yano, Hiroshi; Sato, Fumihiko; Yatani, Hirofumi; Yoshida, Atsushi

    2017-09-27

    Rhythmic masticatory muscle activity can be a normal variant of oromotor activity, which can be exaggerated in patients with sleep bruxism. However, few studies have tested the possibility in naturally sleeping animals to study the neurophysiological mechanisms of rhythmic masticatory muscle activity. This study aimed to investigate the similarity of cortical, cardiac and electromyographic manifestations of rhythmic masticatory muscle activity occurring during non-rapid eye movement sleep between guinea pigs and human subjects. Polysomnographic recordings were made in 30 freely moving guinea pigs and in eight healthy human subjects. Burst cycle length, duration and activity of rhythmic masticatory muscle activity were compared with those for chewing. The time between R-waves in the electrocardiogram (RR interval) and electroencephalogram power spectrum were calculated to assess time-course changes in cardiac and cortical activities in relation to rhythmic masticatory muscle activity. In animals, in comparison with chewing, rhythmic masticatory muscle activity had a lower burst activity, longer burst duration and longer cycle length (P motor activation in comparison to human subjects. © 2017 European Sleep Research Society.

  12. Spectral shifts of mammalian ultraviolet-sensitive pigments (short wavelength-sensitive opsin 1) are associated with eye length and photic niche evolution.

    Science.gov (United States)

    Emerling, Christopher A; Huynh, Hieu T; Nguyen, Minh A; Meredith, Robert W; Springer, Mark S

    2015-11-22

    Retinal opsin photopigments initiate mammalian vision when stimulated by light. Most mammals possess a short wavelength-sensitive opsin 1 (SWS1) pigment that is primarily sensitive to either ultraviolet or violet light, leading to variation in colour perception across species. Despite knowledge of both ultraviolet- and violet-sensitive SWS1 classes in mammals for 25 years, the adaptive significance of this variation has not been subjected to hypothesis testing, resulting in minimal understanding of the basis for mammalian SWS1 spectral tuning evolution. Here, we gathered data on SWS1 for 403 mammal species, including novel SWS1 sequences for 97 species. Ancestral sequence reconstructions suggest that the most recent common ancestor of Theria possessed an ultraviolet SWS1 pigment, and that violet-sensitive pigments evolved at least 12 times in mammalian history. We also observed that ultraviolet pigments, previously considered to be a rarity, are common in mammals. We then used phylogenetic comparative methods to test the hypotheses that the evolution of violet-sensitive SWS1 is associated with increased light exposure, extended longevity and longer eye length. We discovered that diurnal mammals and species with longer eyes are more likely to have violet-sensitive pigments and less likely to possess UV-sensitive pigments. We hypothesize that (i) as mammals evolved larger body sizes, they evolved longer eyes, which limited transmittance of ultraviolet light to the retina due to an increase in Rayleigh scattering, and (ii) as mammals began to invade diurnal temporal niches, they evolved lenses with low UV transmittance to reduce chromatic aberration and/or photo-oxidative damage. © 2015 The Author(s).

  13. Eye Tracking Based Control System for Natural Human-Computer Interaction

    Directory of Open Access Journals (Sweden)

    Xuebai Zhang

    2017-01-01

    Full Text Available Eye movement can be regarded as a pivotal real-time input medium for human-computer communication, which is especially important for people with physical disability. In order to improve the reliability, mobility, and usability of eye tracking technique in user-computer dialogue, a novel eye control system with integrating both mouse and keyboard functions is proposed in this paper. The proposed system focuses on providing a simple and convenient interactive mode by only using user’s eye. The usage flow of the proposed system is designed to perfectly follow human natural habits. Additionally, a magnifier module is proposed to allow the accurate operation. In the experiment, two interactive tasks with different difficulty (searching article and browsing multimedia web were done to compare the proposed eye control tool with an existing system. The Technology Acceptance Model (TAM measures are used to evaluate the perceived effectiveness of our system. It is demonstrated that the proposed system is very effective with regard to usability and interface design.

  14. Eye Tracking Based Control System for Natural Human-Computer Interaction.

    Science.gov (United States)

    Zhang, Xuebai; Liu, Xiaolong; Yuan, Shyan-Ming; Lin, Shu-Fan

    2017-01-01

    Eye movement can be regarded as a pivotal real-time input medium for human-computer communication, which is especially important for people with physical disability. In order to improve the reliability, mobility, and usability of eye tracking technique in user-computer dialogue, a novel eye control system with integrating both mouse and keyboard functions is proposed in this paper. The proposed system focuses on providing a simple and convenient interactive mode by only using user's eye. The usage flow of the proposed system is designed to perfectly follow human natural habits. Additionally, a magnifier module is proposed to allow the accurate operation. In the experiment, two interactive tasks with different difficulty (searching article and browsing multimedia web) were done to compare the proposed eye control tool with an existing system. The Technology Acceptance Model (TAM) measures are used to evaluate the perceived effectiveness of our system. It is demonstrated that the proposed system is very effective with regard to usability and interface design.

  15. A role of the human thalamus in predicting the perceptual consequences of eye movements.

    Science.gov (United States)

    Ostendorf, Florian; Liebermann, Daniela; Ploner, Christoph J

    2013-01-01

    Internal monitoring of oculomotor commands may help to anticipate and keep track of changes in perceptual input imposed by our eye movements. Neurophysiological studies in non-human primates identified corollary discharge (CD) signals of oculomotor commands that are conveyed via thalamus to frontal cortices. We tested whether disruption of these monitoring pathways on the thalamic level impairs the perceptual matching of visual input before and after an eye movement in human subjects. Fourteen patients with focal thalamic stroke and 20 healthy control subjects performed a task requiring a perceptual judgment across eye movements. Subjects reported the apparent displacement of a target cue that jumped unpredictably in sync with a saccadic eye movement. In a critical condition of this task, six patients exhibited clearly asymmetric perceptual performance for rightward vs. leftward saccade direction. Furthermore, perceptual judgments in seven patients systematically depended on oculomotor targeting errors, with self-generated targeting errors erroneously attributed to external stimulus jumps. Voxel-based lesion-symptom mapping identified an area in right central thalamus as critical for the perceptual matching of visual space across eye movements. Our findings suggest that trans-thalamic CD transmission decisively contributes to a correct prediction of the perceptual consequences of oculomotor actions.

  16. A role of the human thalamus in predicting the perceptual consequences of eye movements

    Directory of Open Access Journals (Sweden)

    Florian eOstendorf

    2013-04-01

    Full Text Available Internal monitoring of oculomotor commands may help to anticipate and keep track of changes in perceptual input imposed by our eye movements. Neurophysiological studies in non-human primates identified corollary discharge signals of oculomotor commands that are conveyed via thalamus to frontal cortices. We tested whether disruption of these monitoring pathways on the thalamic level impairs the perceptual matching of visual input before and after an eye movement in human subjects. Fourteen patients with focal thalamic stroke and twenty healthy control subjects performed a task requiring a perceptual judgment across eye movements. Subjects reported the apparent displacement of a target cue that jumped unpredictably in sync with a saccadic eye movement. In a critical condition of this task, six patients exhibited clearly asymmetric perceptual performance for rightward versus leftward saccade direction. Furthermore, perceptual judgments in seven patients systematically depended on oculomotor targeting errors, with self-generated targeting errors erroneously attributed to external stimulus jumps. Voxel-based lesion-symptom mapping identified an area in right central thalamus as critical for the perceptual matching of visual space across eye movements. Our findings suggest that trans-thalamic corollary discharge transmission decisively contributes to a correct prediction of the perceptual consequences of oculomotor actions.

  17. Controlled delivery of antiangiogenic drug to human eye tissue using a MEMS device

    KAUST Repository

    Pirmoradi, Fatemeh Nazly

    2013-01-01

    We demonstrate an implantable MEMS drug delivery device to conduct controlled and on-demand, ex vivo drug transport to human eye tissue. Remotely operated drug delivery to human post-mortem eyes was performed via a MEMS device. The developed curved packaging cover conforms to the eyeball thereby preventing the eye tissue from contacting the actuating membrane. By pulsed operation of the device, using an externally applied magnetic field, the drug released from the device accumulates in a cavity adjacent to the tissue. As such, docetaxel (DTX), an antiangiogenic drug, diffuses through the eye tissue, from sclera and choroid to retina. DTX uptake by sclera and choroid were measured to be 1.93±0.66 and 7.24±0.37 μg/g tissue, respectively, after two hours in pulsed operation mode (10s on/off cycles) at 23°C. During this period, a total amount of 192 ng DTX diffused into the exposed tissue. This MEMS device shows great potential for the treatment of ocular posterior segment diseases such as diabetic retinopathy by introducing a novel way of drug administration to the eye. © 2013 IEEE.

  18. The physiological period length of the human circadian clock in vivo is directly proportional to period in human fibroblasts.

    Directory of Open Access Journals (Sweden)

    Lucia Pagani

    Full Text Available BACKGROUND: Diurnal behavior in humans is governed by the period length of a circadian clock in the suprachiasmatic nuclei of the brain hypothalamus. Nevertheless, the cell-intrinsic mechanism of this clock is present in most cells of the body. We have shown previously that for individuals of extreme chronotype ("larks" and "owls", clock properties measured in human fibroblasts correlated with extreme diurnal behavior. METHODOLOGY/PRINCIPAL FINDINGS: In this study, we have measured circadian period in human primary fibroblasts taken from normal individuals and, for the first time, compared it directly with physiological period measured in vivo in the same subjects. Human physiological period length was estimated via the secretion pattern of the hormone melatonin in two different groups of sighted subjects and one group of totally blind subjects, each using different methods. Fibroblast period length was measured via cyclical expression of a lentivirally delivered circadian reporter. Within each group, a positive linear correlation was observed between circadian period length in physiology and in fibroblast gene expression. Interestingly, although blind individuals showed on average the same fibroblast clock properties as sighted ones, their physiological periods were significantly longer. CONCLUSIONS/SIGNIFICANCE: We conclude that the period of human circadian behaviour is mostly driven by cellular clock properties in normal individuals and can be approximated by measurement in peripheral cells such as fibroblasts. Based upon differences among sighted and blind subjects, we also speculate that period can be modified by prolonged unusual conditions such as the total light deprivation of blindness.

  19. Two eyes, one vision: binocular motion perception in human visual cortex

    NARCIS (Netherlands)

    Barendregt, M.

    2016-01-01

    An important aspect of human vision is the fact that it is binocular, i.e. that we have two eyes. As a result, the brain nearly always receives two slightly different images of the same visual scene. Yet, we only perceive a single image and thus our brain has to actively combine the binocular visual

  20. A Simple Model of the Accommodating Lens of the Human Eye

    Science.gov (United States)

    Oommen, Vinay; Kanthakumar, Praghalathan

    2014-01-01

    The human eye is often discussed as optically equivalent to a photographic camera. The iris is compared with the shutter, the pupil to the aperture, and the retina to the film, and both have lens systems to focus rays of light. Although many similarities exist, a major difference between the two systems is the mechanism involved in focusing an…

  1. Different cellular effects of four anti-inflammatory eye drops on human corneal epithelial cells: independent in active components.

    Science.gov (United States)

    Qu, Mingli; Wang, Yao; Yang, Lingling; Zhou, Qingjun

    2011-01-01

    To evaluate and compare the cellular effects of four commercially available anti-inflammatory eye drops and their active components on human corneal epithelial cells (HCECs) in vitro. The cellular effects of four eye drops (Bromfenac Sodium Hydrate Eye Drops, Pranoprofen Eye Drops, Diclofenac Sodium Eye Drops, and Tobramycin & Dex Eye Drops) and their corresponding active components were evaluated in an HCEC line with five in vitro assays. Cell proliferation and migration were measured using 3-(4,5)-dimethylthiahiazo (-z-y1)-3 5-di-phenytetrazoliumromide (MTT) assay and transwell migration assay. Cell damage was determined with the lactate dehydrogenase (LDH) assay. Cell viability and median lethal time (LT₅₀) were measured by 7-amino-actinomycin D (7-AAD) staining and flow cytometry analysis. Cellular effects after exposure of HCECs to the four anti-inflammatory eye drops were concentration dependent. The differences of cellular toxicity on cell proliferation became significant at lower concentrations (Eye Drops showed significant increasing effects on cell damage and viability when compared with the other three solutions. Tobramycin & Dex Eye Drops inhibited the migration of HCECs significantly. Tobramycin & Dex Eye Drops showed the quickest effect on cell viability: the LT₅₀ was 3.28, 9.23, 10.38, and 23.80 min for Tobramycin & Dex Eye Drops, Diclofenac Sodium Eye Drops, Pranoprofen Eye Drops, and Bromfenac Sodium Hydrate Eye Drops, respectively. However, the comparisons of cellular toxicity revealed significant differences between the eye drops and their active components under the same concentration. The corneal epithelial toxicity differences among the active components of the four eye drops became significant as higher concentration (>0.020%). The four anti-inflammatory eye drops showed different cellular effects on HCECs, and the toxicity was not related with their active components, which provides new reference for the clinical application and drug

  2. The neurophysiology of human touch and eye gaze and its effects on therapeutic relationships and healing: a scoping review protocol.

    Science.gov (United States)

    Kerr, Fiona; Wiechula, Rick; Feo, Rebecca; Schultz, Tim; Kitson, Alison

    2016-04-01

    The objective of this scoping review is to examine and map the range of neurophysiological impacts of human touch and eye gaze, and better understand their possible links to the therapeutic relationship and the process of healing. The specific question is "what neurophysiological impacts of human touch and eye gaze have been reported in relation to therapeutic relationships and healing?"

  3. Accommodation in human eye models: a comparison between the optical designs of Navarro, Arizona and Liou-Brennan.

    Science.gov (United States)

    Zoulinakis, Georgios; Esteve-Taboada, Jose Juan; Ferrer-Blasco, Teresa; Madrid-Costa, David; Montés-Micó, Robert

    2017-01-01

    To simulate and compare accommodation in accommodative and non-accommodative human eye models. Ray tracing and optical design program was used. Three eye models were designed and studied: the Navarro, the Arizona and the Liou-Brennan. In order to make the Navarro and Liou-Brennan models to accommodate, specific geometric parameters of the models were altered with values that were chosen from the literature. For the Arizona model, its' mathematical functions for accommodation were used for the same accommodative demands. The simulation included four distances of accommodation for each model: at infinity, 3, 1 and 0.5 m.The results were diffraction images of a "letter F" for graphical comparison, spot diagrams on the retinal field and Modulation Transfer Function (MTF) graphs. Zernike coefficients for the aberrations, Airy disk diameter, root mean square (RMS) error diameter and total axial length of the model were provided from the program. These were compared between them in all distances. The Navarro model had the smallest axial length change as a simple model. The Arizona did not change its axial length because it is designed to be accommodative. The Liou-Brennan model had different results concerning the aberrations because of the decentration of the pupil. The MTF graphs showed small differences between the models because of the differences in their designs. All the three models are able to simulate accommodation with the expected results. There is no model that can be assumed as the best choice. Accommodation can be simulated in non-accommodativemodels and in customized ones.

  4. Seeing with the nano-eye: accessing structure, function, and dynamics of matter on its natural length and time scales

    Science.gov (United States)

    Raschke, Markus

    2015-03-01

    To understand and ultimately control the properties of most functional materials, from molecular soft-matter to quantum materials, requires access to the structure, coupling, and dynamics on the elementary time and length scales that define the microscopic interactions in these materials. To gain the desired nanometer spatial resolution with simultaneous spectroscopic specificity we combine scanning probe microscopy with different optical, including coherent, nonlinear, and ultrafast spectroscopies. The underlying near-field interaction mediated by the atomic-force or scanning tunneling microscope tip provides the desired deep-sub wavelength nano-focusing enabling few-nm spatial resolution. I will introduce our generalization of the approach in terms of the near-field impedance matching to a quantum system based on special optical antenna-tip designs. The resulting enhanced and qualitatively new forms of light-matter interaction enable measurements of quantum dynamics in an interacting environment or to image the electromagnetic local density of states of thermal radiation. Other applications include the inter-molecular coupling and dynamics in soft-matter hetero-structures, surface plasmon interferometry as a probe of electronic structure and dynamics in graphene, and quantum phase transitions in correlated electron materials. These examples highlight the general applicability of the new near-field microscopy approach, complementing emergent X-ray and electron imaging tools, aiming towards the ultimate goal of probing matter on its most elementary spatio-temporal level.

  5. Analysis of the speckle properties in a laser projection system based on a human eye model.

    Science.gov (United States)

    Cui, Zhe; Wang, Anting; Ma, Qianli; Ming, Hai

    2014-03-01

    In this paper, the properties of the speckle that is observed by humans in laser projection systems are theoretically analyzed. The speckle pattern on the fovea of the human retina is numerically simulated by introducing a chromatic human eye model. The results show that the speckle contrast experienced by humans is affected by the light intensity of the projected images and the wavelength of the laser source when considering the paracentral vision. Furthermore, the image quality is also affected by these two parameters. We believe that these results are useful for evaluating the speckle noise in laser projection systems.

  6. Calcaneus length determines running economy: implications for endurance running performance in modern humans and Neandertals.

    Science.gov (United States)

    Raichlen, David A; Armstrong, Hunter; Lieberman, Daniel E

    2011-03-01

    The endurance running (ER) hypothesis suggests that distance running played an important role in the evolution of the genus Homo. Most researchers have focused on ER performance in modern humans, or on reconstructing ER performance in Homo erectus, however, few studies have examined ER capabilities in other members of the genus Homo. Here, we examine skeletal correlates of ER performance in modern humans in order to evaluate the energetics of running in Neandertals and early Homo sapiens. Recent research suggests that running economy (the energy cost of running at a given speed) is strongly related to the length of the Achilles tendon moment arm. Shorter moment arms allow for greater storage and release of elastic strain energy, reducing energy costs. Here, we show that a skeletal correlate of Achilles tendon moment arm length, the length of the calcaneal tuber, does not correlate with walking economy, but correlates significantly with running economy and explains a high proportion of the variance (80%) in cost between individuals. Neandertals had relatively longer calcaneal tubers than modern humans, which would have increased their energy costs of running. Calcaneal tuber lengths in early H. sapiens do not significantly differ from those of extant modern humans, suggesting Neandertal ER economy was reduced relative to contemporaneous anatomically modern humans. Endurance running is generally thought to be beneficial for gaining access to meat in hot environments, where hominins could have used pursuit hunting to run prey taxa into hyperthermia. We hypothesize that ER performance may have been reduced in Neandertals because they lived in cold climates. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. The effects of ultraviolet-A radiation on visual evoked potentials in the young human eye

    International Nuclear Information System (INIS)

    Sanford, B.E.; Beacham, S.; Hanifin, J.P.; Hannon, P.; Streletz, L.; Sliney, D.; Brainard, G.C.

    1996-01-01

    A recent study from this laboratory using visual evoked potentials (VEPs) demonstrated that children's eyes are capable of detecting ultraviolet radiation. The aim of this study was to compare dose-response relationships in two age groups, 6-10 years (n=10) and 20-25 years (n=10). Under photopic viewing conditions (550 lux), exposures of monochromatic UV-A (339 nm) and visible radiation (502 nm) were correlated to VEPs. The results demonstrate that monochromatic UV-A can elicit age and dose dependent responses in the human visual system, suggesting that the eyes of children are more responsive to UV stimuli than the eyes of young adults. (au) 17 refs

  8. Temperature elevation in the eye of anatomically based human head models for plane-wave exposures

    International Nuclear Information System (INIS)

    Hirata, A; Watanabe, S; Fujiwara, O; Kojima, M; Sasaki, K; Shiozawa, T

    2007-01-01

    This study investigated the temperature elevation in the eye of anatomically based human head models for plane-wave exposures. The finite-difference time-domain method is used for analyzing electromagnetic absorption and temperature elevation. The eyes in the anatomic models have average dimensions and weight. Computational results show that the ratio of maximum temperature in the lens to the eye-average SAR (named 'heating factor for the lens') is almost uniform (0.112-0.147 deg. C kg W -1 ) in the frequency region below 3 GHz. Above 3 GHz, this ratio increases gradually with an increase of frequency, which is attributed to the penetration depth of an electromagnetic wave. Particular attention is paid to the difference in the heating factor for the lens between this study and earlier works. Considering causes clarified in this study, compensated heating factors in all these studies are found to be in good agreement

  9. Objective measurement of intraocular forward light scatter using Hartmann-Shack spot patterns from clinical aberrometers. Model-eye and human-eye study.

    Science.gov (United States)

    Cerviño, Alejandro; Bansal, Dheeraj; Hosking, Sarah L; Montés-Micó, Robert

    2008-07-01

    To apply software-based image-analysis tools to objectively determine intraocular scatter determined from clinically derived Hartmann-Shack patterns. Aston Academy of Life Sciences, Aston University, Birmingham, United Kingdom, and Department of Optics, University of Valencia, Valencia, Spain. Purpose-designed image-analysis software was used to quantify scatter from centroid patterns obtained using a clinical Hartmann-Shack analyzer (WASCA, Zeiss/Meditec). Three scatter values, as the maximum standard deviation within a lenslet for all lenslets in the pattern, were obtained in 6 model eyes and 10 human eyes. In the model-eye sample, patterns were obtained in 4 sessions: 2 without realigning between measurements, 1 with realignment, and 1 with an angular shift of 6 degrees from the instrument axis. Three measurements were made in the human eyes with the C-Quant straylight meter (Oculus) to obtain psychometric and objective measures of retinal straylight. Analysis of variance, intraclass correlation coefficients, coefficient of repeatability (CoR), and correlations were used to determine intrasession and intersession repeatability and the relationship between measures. No significant differences were found between the sessions in the model eye (P=.234). The mean CoR was less than 10% in all model- and human-eye sessions. After incomplete patterns were removed, good correlation was achieved between psychometric and objective scatter measurements despite the small sample size (n=6; r=-0.831; P=.040). The methodology was repeatable in model and human eyes, strong against realignment and misalignment, and sensitive. Clinical application would benefit from effective use of the sensor's dynamic range.

  10. Modeling the influence of LASIK surgery on optical properties of the human eye

    Science.gov (United States)

    Szul-Pietrzak, Elżbieta; Hachoł, Andrzej; Cieślak, Krzysztof; Drożdż, Ryszard; Podbielska, Halina

    2011-11-01

    The aim was to model the influence of LASIK surgery on the optical parameters of the human eye and to ascertain which factors besides the central corneal radius of curvature and central thickness play the major role in postsurgical refractive change. Ten patients were included in the study. Pre- and postsurgical measurements included standard refraction, anterior corneal curvature and pachymetry. The optical model used in the analysis was based on the Le Grand and El Hage schematic eye, modified by the measured individual parameters of corneal geometry. A substantial difference between eye refractive error measured after LASIK and estimated from the eye model was observed. In three patients, full correction of the refractive error was achieved. However, analysis of the visual quality in terms of spot diagrams and optical transfer functions of the eye optical system revealed some differences in these measurements. This suggests that other factors besides corneal geometry may play a major role in postsurgical refraction. In this paper we investigated whether the biomechanical properties of the eyeball and changes in intraocular pressure could account for the observed discrepancies.

  11. Analysis of toxic and heavy metals in cataract extraction from human eyes

    International Nuclear Information System (INIS)

    Tanvir, R.; Qureshi, S.A.; Ahmed, R.

    1999-01-01

    Surma and many other substances are frequently used for the treatment of eyes and for cosmetic purposes, which may contain large quantities of toxic and heavy metals particularly lead. Toxic metals may also enter into the body through different food chain system and also due to heavy traffic and contaminated dusts in the air of the overcrowded cities. Eyes being exposed part of human body has maximum chances to get in contact with polluted atmosphere. This study has been undertaken to find the role of toxic elements in the formation of cataract in eyes. Samples of eye lenses were collected and carefully digested in 3 ml of conc. HClO/sub 4/ and 1 ml of conc. HNO/sub 3/. Then analysis of Zn, Cd, Pb, Cu, was carried out in 0.02 m HClO/sub 4/ using differential pulse anodic stripping voltametry. Levels of Zn, Cd, Pb and Cu in eye lenses are from 324 - 5746 mug/g, 3 - 240 mug/g, 3 - 240 mug/g, 25 - 120 mug /g and 23 - 485 mug/g, respectively. Chemical composition of ocular fluid indicates that Pb, Cd, Cu, Zn are not present in it normally. In addition to other factors , role of heavy and toxic metals in the formation of cataract cannot be overlooked. Therefore, use of surma and other cosmetics should be discouraged. (author)

  12. Recruitment of single human low-threshold motor units with increasing loads at different muscle lengths.

    Science.gov (United States)

    McNulty, P A; Cresswell, A G

    2004-06-01

    We investigated the recruitment behaviour of low threshold motor units in flexor digitorum superficialis by altering two biomechanical constraints: the load against which the muscle worked and the initial muscle length. The load was increased using isotonic (low load), loaded dynamic (intermediate load) and isometric (high load) contractions in two studies. The initial muscle position reflected resting muscle length in series A, and a longer length with digit III fully extended in series B. Intramuscular EMG was recorded from 48 single motor units in 10 experiments on five healthy subjects, 21 units in series A and 27 in series B, while subjects performed ramp up, hold and ramp down contractions. Increasing the load on the muscle decreased the force, displacement and firing rate of single motor units at recruitment at shorter muscle lengths (Precruitment pattern was observed between loaded dynamic and isotonic contractions, but not between isometric and loaded dynamic contractions. Thus, the recruitment properties of single motor units in human flexor digitorum superficialis are sensitive to changes in both imposed external loads and the initial length of the muscle.

  13. Edge detection of iris of the eye for human biometric identification system

    Directory of Open Access Journals (Sweden)

    Kateryna O. Tryfonova

    2015-03-01

    Full Text Available Method of human biometric identification by iris of the eye is considered as one of the most accurate and reliable methods of identification. Aim of the research is to solve the problem of edge detection of digital image of the human eye iris to be able to implement human biometric identification system by means of mobile device. To achieve this aim the algorithm of edge detection by Canny is considered in work. It consists of the following steps: smoothing, finding gradients, non-maximum suppression, double thresholding with hysteresis. The software implementation of the Canny algorithm is carried out for the Android mobile platform with the use of high level programming language Java.

  14. Thermal behavior of human eye in relation with change in blood perfusion, porosity, evaporation and ambient temperature.

    Science.gov (United States)

    Rafiq, Aasma; Khanday, M A

    2016-12-01

    Extreme environmental and physiological conditions present challenges for thermal processes in body tissues including multi-layered human eye. A mathematical model has been formulated in this direction to study the thermal behavior of the human eye in relation with the change in blood perfusion, porosity, evaporation and environmental temperatures. In this study, a comprehensive thermal analysis has been performed on the multi-layered eye using Pennes' bio-heat equation with appropriate boundary and interface conditions. The variational finite element method and MATLAB software were used for the solution purpose and simulation of the results. The thermoregulatory effect due to blood perfusion rate, porosity, ambient temperature and evaporation at various regions of human eye was illustrated mathematically and graphically. The main applications of this model are associated with the medical sciences while performing laser therapy and other thermoregulatory investigation on human eye. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Effects of aqueous humor hydrodynamics on human eye heat transfer under external heat sources.

    Science.gov (United States)

    Tiang, Kor L; Ooi, Ean H

    2016-08-01

    The majority of the eye models developed in the late 90s and early 00s considers only heat conduction inside the eye. This assumption is not entirely correct, since the anterior and posterior chambers are filled aqueous humor (AH) that is constantly in motion due to thermally-induced buoyancy. In this paper, a three-dimensional model of the human eye is developed to investigate the effects AH hydrodynamics have on the human eye temperature under exposure to external heat sources. If the effects of AH flow are negligible, then future models can be developed without taking them into account, thus simplifying the modeling process. Two types of external thermal loads are considered; volumetric and surface irradiation. Results showed that heat convection due to AH flow contributes to nearly 95% of the total heat flow inside the anterior chamber. Moreover, the circulation inside the anterior chamber can cause an upward shift of the location of hotspot. This can have significant consequences to our understanding of heat-induced cataractogenesis. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  16. From time series analysis to a biomechanical multibody model of the human eye

    International Nuclear Information System (INIS)

    Pascolo, P.; Carniel, R.

    2009-01-01

    A mechanical model of the human eye is presented aimed at estimating the level of muscular activation. The applicability of the model in the biomedical field is discussed. Human eye movements studied in the laboratory are compared with the ones produced by a virtual eye described in kinematical terms and subject to the dynamics of six actuators, as many as the muscular systems devoted to the eye motion control. The definition of an error function between the experimental and the numerical response and the application of a suitable law that links activation and muscular force are at the base of the proposed methodology. The aim is the definition of a simple conceptual tool that could help the specialist in the diagnosis of potential physiological disturbances of saccadic and nystagmic movements but can also be extended in a second phase when more sophisticated data become available. The work is part of a collaboration between the Functional Mechanics Laboratory of the University and the Neurophysiopatology Laboratory of the 'S. Maria della Misericordia' Hospital in Udine, Italy.

  17. Simulated human eye retina adaptive optics imaging system based on a liquid crystal on silicon device

    International Nuclear Information System (INIS)

    Jiang Baoguang; Cao Zhaoliang; Mu Quanquan; Hu Lifa; Li Chao; Xuan Li

    2008-01-01

    In order to obtain a clear image of the retina of model eye, an adaptive optics system used to correct the wave-front error is introduced in this paper. The spatial light modulator that we use here is a liquid crystal on a silicon device instead of a conversional deformable mirror. A paper with carbon granule is used to simulate the retina of human eye. The pupil size of the model eye is adjustable (3-7 mm). A Shack–Hartman wave-front sensor is used to detect the wave-front aberration. With this construction, a value of peak-to-valley is achieved to be 0.086 λ, where λ is wavelength. The modulation transfer functions before and after corrections are compared. And the resolution of this system after correction (691p/m) is very close to the dirraction limit resolution. The carbon granule on the white paper which has a size of 4.7 μm is seen clearly. The size of the retina cell is between 4 and 10 mu;m. So this system has an ability to image the human eye's retina. (classical areas of phenomenology)

  18. What interests them in the pictures?--differences in eye-tracking between rhesus monkeys and humans.

    Science.gov (United States)

    Hu, Ying-Zhou; Jiang, Hui-Hui; Liu, Ci-Rong; Wang, Jian-Hong; Yu, Cheng-Yang; Carlson, Synnöve; Yang, Shang-Chuan; Saarinen, Veli-Matti; Rizak, Joshua D; Tian, Xiao-Guang; Tan, Hen; Chen, Zhu-Yue; Ma, Yuan-Ye; Hu, Xin-Tian

    2013-10-01

    Studies estimating eye movements have demonstrated that non-human primates have fixation patterns similar to humans at the first sight of a picture. In the current study, three sets of pictures containing monkeys, humans or both were presented to rhesus monkeys and humans. The eye movements on these pictures by the two species were recorded using a Tobii eye-tracking system. We found that monkeys paid more attention to the head and body in pictures containing monkeys, whereas both monkeys and humans paid more attention to the head in pictures containing humans. The humans always concentrated on the eyes and head in all the pictures, indicating the social role of facial cues in society. Although humans paid more attention to the hands than monkeys, both monkeys and humans were interested in the hands and what was being done with them in the pictures. This may suggest the importance and necessity of hands for survival. Finally, monkeys scored lower in eye-tracking when fixating on the pictures, as if they were less interested in looking at the screen than humans. The locations of fixation in monkeys may provide insight into the role of eye movements in an evolutionary context.

  19. Effect of human milk as a treatment for dry eye syndrome in a mouse model.

    Science.gov (United States)

    Diego, Jose L; Bidikov, Luke; Pedler, Michelle G; Kennedy, Jeffrey B; Quiroz-Mercado, Hugo; Gregory, Darren G; Petrash, J Mark; McCourt, Emily A

    Dry eye syndrome (DES) affects millions of people worldwide. Homeopathic remedies to treat a wide variety of ocular diseases have previously been documented in the literature, but little systematic work has been performed to validate the remedies' efficacy using accepted laboratory models of disease. The purpose of this study was to evaluate the efficacy of human milk and nopal cactus (prickly pear), two widely used homeopathic remedies, as agents to reduce pathological markers of DES. The previously described benzalkonium chloride (BAK) dry eye mouse model was used to study the efficacy of human milk and nopal cactus (prickly pear). BAK (0.2%) was applied to the mouse ocular surface twice daily to induce dry eye pathology. Fluorescein staining was used to verify that the animals had characteristic signs of DES. After induction of DES, the animals were treated with human milk (whole and fat-reduced), nopal, nopal extract derivatives, or cyclosporine four times daily for 7 days. Punctate staining and preservation of corneal epithelial thickness, measured histologically at the end of treatment, were used as indices of therapeutic efficacy. Treatment with BAK reduced the mean corneal epithelial thickness from 36.77±0.64 μm in the control mice to 21.29±3.2 μm. Reduction in corneal epithelial thickness was largely prevented by administration of whole milk (33.2±2.5 μm) or fat-reduced milk (36.1±1.58 μm), outcomes that were similar to treatment with cyclosporine (38.52±2.47 μm), a standard in current dry eye therapy. In contrast, crude or filtered nopal extracts were ineffective at preventing BAK-induced loss of corneal epithelial thickness (24.76±1.78 μm and 27.99±2.75 μm, respectively), as were solvents used in the extraction of nopal materials (26.53±1.46 μm for ethyl acetate, 21.59±5.87 μm for methanol). Epithelial damage, as reflected in the punctate scores, decreased over 4 days of treatment with whole and fat-reduced milk but continued to

  20. Meiotic gene-conversion rate and tract length variation in the human genome.

    Science.gov (United States)

    Padhukasahasram, Badri; Rannala, Bruce

    2013-02-27

    Meiotic recombination occurs in the form of two different mechanisms called crossing-over and gene-conversion and both processes have an important role in shaping genetic variation in populations. Although variation in crossing-over rates has been studied extensively using sperm-typing experiments, pedigree studies and population genetic approaches, our knowledge of variation in gene-conversion parameters (ie, rates and mean tract lengths) remains far from complete. To explore variability in population gene-conversion rates and its relationship to crossing-over rate variation patterns, we have developed and validated using coalescent simulations a comprehensive Bayesian full-likelihood method that can jointly infer crossing-over and gene-conversion rates as well as tract lengths from population genomic data under general variable rate models with recombination hotspots. Here, we apply this new method to SNP data from multiple human populations and attempt to characterize for the first time the fine-scale variation in gene-conversion parameters along the human genome. We find that the estimated ratio of gene-conversion to crossing-over rates varies considerably across genomic regions as well as between populations. However, there is a great degree of uncertainty associated with such estimates. We also find substantial evidence for variation in the mean conversion tract length. The estimated tract lengths did not show any negative relationship with the local heterozygosity levels in our analysis.European Journal of Human Genetics advance online publication, 27 February 2013; doi:10.1038/ejhg.2013.30.

  1. Dose conversion coefficients for photon exposure of the human eye lens

    Science.gov (United States)

    Behrens, R.; Dietze, G.

    2011-01-01

    In recent years, several papers dealing with the eye lens dose have been published, because epidemiological studies implied that the induction of cataracts occurs even at eye lens doses of less than 500 mGy. Different questions were addressed: Which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens? Is a new definition of the dose quantity Hp(3) based on a cylinder phantom to represent the human head necessary? Are current conversion coefficients from fluence to equivalent dose to the lens sufficiently accurate? To investigate the latter question, a realistic model of the eye including the inner structure of the lens was developed. Using this eye model, conversion coefficients for electrons have already been presented. In this paper, the same eye model—with the addition of the whole body—was used to calculate conversion coefficients from fluence (and air kerma) to equivalent dose to the lens for photon radiation from 5 keV to 10 MeV. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are similar between 40 keV and 1 MeV and lower by up to a factor of 5 and 7 for photon energies at about 10 keV and 10 MeV, respectively. Above 1 MeV, the new values (calculated without kerma approximation) should be applied in pure photon radiation fields, while the values adopted by the ICRP in 1996 (calculated with kerma approximation) should be applied in case a significant contribution from secondary electrons originating outside the body is present.

  2. Dose conversion coefficients for photon exposure of the human eye lens

    International Nuclear Information System (INIS)

    Behrens, R; Dietze, G

    2011-01-01

    In recent years, several papers dealing with the eye lens dose have been published, because epidemiological studies implied that the induction of cataracts occurs even at eye lens doses of less than 500 mGy. Different questions were addressed: Which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens? Is a new definition of the dose quantity H p (3) based on a cylinder phantom to represent the human head necessary? Are current conversion coefficients from fluence to equivalent dose to the lens sufficiently accurate? To investigate the latter question, a realistic model of the eye including the inner structure of the lens was developed. Using this eye model, conversion coefficients for electrons have already been presented. In this paper, the same eye model-with the addition of the whole body-was used to calculate conversion coefficients from fluence (and air kerma) to equivalent dose to the lens for photon radiation from 5 keV to 10 MeV. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are similar between 40 keV and 1 MeV and lower by up to a factor of 5 and 7 for photon energies at about 10 keV and 10 MeV, respectively. Above 1 MeV, the new values (calculated without kerma approximation) should be applied in pure photon radiation fields, while the values adopted by the ICRP in 1996 (calculated with kerma approximation) should be applied in case a significant contribution from secondary electrons originating outside the body is present.

  3. The effects of metamaterial on electromagnetic fields absorption characteristics of human eye tissues.

    Science.gov (United States)

    Gasmelseed, Akram; Yunus, Jasmy

    2014-01-01

    The interaction of a dipole antenna with a human eye model in the presence of a metamaterial is investigated in this paper. The finite difference time domain (FDTD) method with convolutional perfectly matched layer (CPML) formulation have been used. A three-dimensional anatomical model of the human eye with resolution of 1.25 mm × 1.25 mm × 1.25 mm was used in this study. The dipole antenna was driven by modulated Gaussian pulse and the numerical study is performed with dipole operating at 900 MHz. The analysis has been done by varying the size and value of electric permittivity of the metamaterial. By normalizing the peak SAR (1 g and 10 g) to 1 W for all examined cases, we observed how the SAR values are not affected by the different permittivity values with the size of the metamaterial kept fixed. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Facilitation of tear fluid secretion by 3% diquafosol ophthalmic solution in normal human eyes.

    Science.gov (United States)

    Yokoi, Norihiko; Kato, Hiroaki; Kinoshita, Shigeru

    2014-01-01

    To evaluate the increase in tear fluid volume induced by 3% diquafosol ophthalmic solution in normal human eyes. Prospective, randomized, double-masked, comparative study. Twenty healthy adults (17 males and 3 females; mean age, 38.8 years) underwent topical instillation of 2 ophthalmic solutions, artificial tears in 1 eye and 3% diquafosol ophthalmic solution in the fellow eye, in a masked manner. The radius of curvature of the central lower tear meniscus was measured at 5, 10, 15, 30, and 60 minutes after instillation by use of reflective meniscometry, and subjects' self-evaluated symptoms of wetness and stinging using a visual analog scale. Changes after instillation in the radius of curvature from baseline (artificial tear group vs diquafosol group; mean ± standard error of the mean) were as follows: at 5 minutes, -0.008 ± 0.012 vs 0.045 ± 0.013; at 10 minutes, 0.001 ± 0.014 vs 0.057 ± 0.016; at 15 minutes, -0.012 ± 0.014 vs 0.037 ± 0.019; at 30 minutes, -0.010 ± 0.016 vs 0.030 ± 0.025; and at 60 minutes, -0.029 ± 0.012 vs -0.020 ± 0.012. The diquafosol group showed significantly greater values from 5 to 30 minutes after instillation. Of the 40 eyes, 13 showed abnormal tear film breakup time (≤5 seconds). The diquafosol group had significantly more wetness at 15 minutes after instillation than did the artificial tear group. Topical instillation of 3% diquafosol ophthalmic solution increases tear fluid on the ocular surface for up to 30 minutes in normal human eyes. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Distribution of absorbed dose in human eye simulated by SRNA-2KG computer code

    International Nuclear Information System (INIS)

    Ilic, R.; Pesic, M.; Pavlovic, R.; Mostacci, D.

    2003-01-01

    Rapidly increasing performances of personal computers and development of codes for proton transport based on Monte Carlo methods will allow, very soon, the introduction of the computer planning proton therapy as a normal activity in regular hospital procedures. A description of SRNA code used for such applications and results of calculated distributions of proton-absorbed dose in human eye are given in this paper. (author)

  6. Optics of the human cornea influence the accuracy of stereo eye-tracking methods: a simulation study

    NARCIS (Netherlands)

    Barsingerhorn, A.D.; Boonstra, F.N.; Goossens, H.H.L.M.

    2017-01-01

    Current stereo eye-tracking methods model the cornea as a sphere with one refractive surface. However, the human cornea is slightly aspheric and has two refractive surfaces. Here we used ray-tracing and the Navarro eye-model to study how these optical properties affect the accuracy of different

  7. Use of eye tracking equipment for human reliability analysis applied to complex system operations

    International Nuclear Information System (INIS)

    Pinheiro, Andre Ricardo Mendonça; Prado, Eugenio Anselmo Pessoa do; Martins, Marcelo Ramos

    2017-01-01

    This article will discuss the preliminary results of an evaluation methodology for the analysis and quantification of manual character errors (human), by monitoring cognitive parameters and skill levels in the operation of a complex control system based on parameters provided by a eye monitoring equipment (Eye Tracker). The research was conducted using a simulator (game) that plays concepts of operation of a nuclear reactor with a split sample for evaluation of aspects of learning, knowledge and standard operating within the context addressed. bridge operators were monitored using the EYE TRACKING, eliminating the presence of the analyst in the evaluation of the operation, allowing the analysis of the results by means of multivariate statistical techniques within the scope of system reliability. The experiments aim to observe state change situations such as stops and scheduled departures, incidents assumptions and common operating characteristics. Preliminary results of this research object indicate that technical and cognitive aspects can contribute to improving the reliability of the available techniques in human reliability, making them more realistic both in the context of quantitative approaches to regulatory and training purposes, as well as reduced incidence of human error. (author)

  8. Use of eye tracking equipment for human reliability analysis applied to complex system operations

    Energy Technology Data Exchange (ETDEWEB)

    Pinheiro, Andre Ricardo Mendonça; Prado, Eugenio Anselmo Pessoa do; Martins, Marcelo Ramos, E-mail: andrericardopinheiro@usp.br, E-mail: eugenio.prado@labrisco.usp.br, E-mail: mrmatins@usp.br [Universidade de Sao Paulo (LABRISCO/USP), Sao Paulo, SP (Brazil). Lab. de Análise, Avaliação e Gerenciamento de Risco

    2017-07-01

    This article will discuss the preliminary results of an evaluation methodology for the analysis and quantification of manual character errors (human), by monitoring cognitive parameters and skill levels in the operation of a complex control system based on parameters provided by a eye monitoring equipment (Eye Tracker). The research was conducted using a simulator (game) that plays concepts of operation of a nuclear reactor with a split sample for evaluation of aspects of learning, knowledge and standard operating within the context addressed. bridge operators were monitored using the EYE TRACKING, eliminating the presence of the analyst in the evaluation of the operation, allowing the analysis of the results by means of multivariate statistical techniques within the scope of system reliability. The experiments aim to observe state change situations such as stops and scheduled departures, incidents assumptions and common operating characteristics. Preliminary results of this research object indicate that technical and cognitive aspects can contribute to improving the reliability of the available techniques in human reliability, making them more realistic both in the context of quantitative approaches to regulatory and training purposes, as well as reduced incidence of human error. (author)

  9. Mathematical modeling of laser linear thermal effects on the anterior layer of the human eye

    Science.gov (United States)

    Rahbar, Sahar; Shokooh-Saremi, Mehrdad

    2018-02-01

    In this paper, mathematical analysis of thermal effects of excimer lasers on the anterior side of the human eye is presented, where linear effect of absorption by the human eye is considered. To this end, Argon Fluoride (ArF) and Holmium:Yttrium-Aluminum-Garent (Ho:YAG) lasers are utilized in this investigation. A three-dimensional model of the human eye with actual dimensions is employed and finite element method (FEM) is utilized to numerically solve the governing (Penne) heat transfer equation. The simulation results suggest the corneal temperature of 263 °C and 83.4 °C for ArF and Ho:YAG laser radiations, respectively, and show less heat penetration depth in comparison to the previous reports. Moreover, the heat transfer equation is solved semi-analytically in one-dimension. It is shown that the exploited simulation results are also consistent with those derived from the semi-analytical solution of the Penne heat transfer equation for both types of laser radiations.

  10. Caffeine increases the velocity of rapid eye movements in unfatigued humans.

    Science.gov (United States)

    Connell, Charlotte J W; Thompson, Benjamin; Turuwhenua, Jason; Hess, Robert F; Gant, Nicholas

    2017-08-01

    Caffeine is a widely used dietary stimulant that can reverse the effects of fatigue on cognitive, motor and oculomotor function. However, few studies have examined the effect of caffeine on the oculomotor system when homeostasis has not been disrupted by physical fatigue. This study examined the influence of a moderate dose of caffeine on oculomotor control and visual perception in participants who were not fatigued. Within a placebo-controlled crossover design, 13 healthy adults ingested caffeine (5 mg·kg -1 body mass) and were tested over 3 h. Eye movements, including saccades, smooth pursuit and optokinetic nystagmus, were measured using infrared oculography. Caffeine was associated with higher peak saccade velocities (472 ± 60° s -1 ) compared to placebo (455 ± 62° s -1 ). Quick phases of optokinetic nystagmus were also significantly faster with caffeine, whereas pursuit eye movements were unchanged. Non-oculomotor perceptual tasks (global motion and global orientation processing) were unaffected by caffeine. These results show that oculomotor control is modulated by a moderate dose of caffeine in unfatigued humans. These effects are detectable in the kinematics of rapid eye movements, whereas pursuit eye movements and visual perception are unaffected. Oculomotor functions may be sensitive to changes in central catecholamines mediated via caffeine's action as an adenosine antagonist, even when participants are not fatigued.

  11. Intraocular Telescopic System Design: Optical and Visual Simulation in a Human Eye Model

    Directory of Open Access Journals (Sweden)

    Georgios Zoulinakis

    2017-01-01

    Full Text Available Purpose. To design an intraocular telescopic system (ITS for magnifying retinal image and to simulate its optical and visual performance after implantation in a human eye model. Methods. Design and simulation were carried out with a ray-tracing and optical design software. Two different ITS were designed, and their visual performance was simulated using the Liou-Brennan eye model. The difference between the ITS was their lenses’ placement in the eye model and their powers. Ray tracing in both centered and decentered situations was carried out for both ITS while visual Strehl ratio (VSOTF was computed using custom-made MATLAB code. Results. The results show that between 0.4 and 0.8 mm of decentration, the VSOTF does not change much either for far or near target distances. The image projection for these decentrations is in the parafoveal zone, and the quality of the image projected is quite similar. Conclusion. Both systems display similar quality while they differ in size; therefore, the choice between them would need to take into account specific parameters from the patient’s eye. Quality does not change too much between 0.4 and 0.8 mm of decentration for either system which gives flexibility to the clinician to adjust decentration to avoid areas of retinal damage.

  12. Simplifying numerical ray tracing for two-dimensional non circularly symmetric models of the human eye.

    Science.gov (United States)

    Jesus, Danilo A; Iskander, D Robert

    2015-12-01

    Ray tracing is a powerful technique to understand the light behavior through an intricate optical system such as that of a human eye. The prediction of visual acuity can be achieved through characteristics of an optical system such as the geometrical point spread function. In general, its precision depends on the number of discrete rays and the accurate surface representation of each eye's components. Recently, a method that simplifies calculation of the geometrical point spread function has been proposed for circularly symmetric systems [Appl. Opt.53, 4784 (2014)]. An extension of this method to 2D noncircularly symmetric systems is proposed. In this method, a two-dimensional ray tracing procedure for an arbitrary number of surfaces and arbitrary surface shapes has been developed where surfaces, rays, and refractive indices are all represented in functional forms being approximated by Chebyshev polynomials. The Liou and Brennan anatomically accurate eye model has been adapted and used for evaluating the method. Further, real measurements of the anterior corneal surface of normal, astigmatic, and keratoconic eyes were substituted for the first surface in the model. The results have shown that performing ray tracing, utilizing the two-dimensional Chebyshev function approximation, is possible for noncircularly symmetric models, and that such calculation can be performed with a newly created Chebfun toolbox.

  13. Intraocular Telescopic System Design: Optical and Visual Simulation in a Human Eye Model.

    Science.gov (United States)

    Zoulinakis, Georgios; Ferrer-Blasco, Teresa

    2017-01-01

    Purpose. To design an intraocular telescopic system (ITS) for magnifying retinal image and to simulate its optical and visual performance after implantation in a human eye model. Methods. Design and simulation were carried out with a ray-tracing and optical design software. Two different ITS were designed, and their visual performance was simulated using the Liou-Brennan eye model. The difference between the ITS was their lenses' placement in the eye model and their powers. Ray tracing in both centered and decentered situations was carried out for both ITS while visual Strehl ratio (VSOTF) was computed using custom-made MATLAB code. Results. The results show that between 0.4 and 0.8 mm of decentration, the VSOTF does not change much either for far or near target distances. The image projection for these decentrations is in the parafoveal zone, and the quality of the image projected is quite similar. Conclusion. Both systems display similar quality while they differ in size; therefore, the choice between them would need to take into account specific parameters from the patient's eye. Quality does not change too much between 0.4 and 0.8 mm of decentration for either system which gives flexibility to the clinician to adjust decentration to avoid areas of retinal damage.

  14. Performance of the SRK/T formula using A-Scan ultrasound biometry after phacoemulsification in eyes with short and long axial lengths.

    Science.gov (United States)

    Karabela, Yunus; Eliacik, Mustafa; Kaya, Faruk

    2016-07-08

    with PE and IOL types, AL, K1, K2, IOL power, and attempted value, besides with MAE and AL, K1, K2, age, attempted, achieved value were found in both groups. The SRK/T formula performs well and shows good predictability in eyes with short and long axial lengths.

  15. Numerical modeling of heat and mass transfer in the human eye under millimeter wave exposure.

    Science.gov (United States)

    Karampatzakis, Andreas; Samaras, Theodoros

    2013-05-01

    Human exposure to millimeter wave (MMW) radiation is expected to increase in the next several years. In this work, we present a thermal model of the human eye under MMW illumination. The model takes into account the fluid dynamics of the aqueous humor and predicts a frequency-dependent reversal of its flow that also depends on the incident power density. The calculated maximum fluid velocity in the anterior chamber and the temperature rise at the corneal apex are reported for frequencies from 40 to 100 GHz and different values of incident power density. Copyright © 2013 Wiley Periodicals, Inc.

  16. Learning robotic eye-arm-hand coordination from human demonstration: a coupled dynamical systems approach.

    Science.gov (United States)

    Lukic, Luka; Santos-Victor, José; Billard, Aude

    2014-04-01

    We investigate the role of obstacle avoidance in visually guided reaching and grasping movements. We report on a human study in which subjects performed prehensile motion with obstacle avoidance where the position of the obstacle was systematically varied across trials. These experiments suggest that reaching with obstacle avoidance is organized in a sequential manner, where the obstacle acts as an intermediary target. Furthermore, we demonstrate that the notion of workspace travelled by the hand is embedded explicitly in a forward planning scheme, which is actively involved in detecting obstacles on the way when performing reaching. We find that the gaze proactively coordinates the pattern of eye-arm motion during obstacle avoidance. This study provides also a quantitative assessment of the coupling between the eye-arm-hand motion. We show that the coupling follows regular phase dependencies and is unaltered during obstacle avoidance. These observations provide a basis for the design of a computational model. Our controller extends the coupled dynamical systems framework and provides fast and synchronous control of the eyes, the arm and the hand within a single and compact framework, mimicking similar control system found in humans. We validate our model for visuomotor control of a humanoid robot.

  17. DNA methyl transferases are differentially expressed in the human anterior eye segment.

    Science.gov (United States)

    Bonnin, Nicolas; Belville, Corinne; Chiambaretta, Frédéric; Sapin, Vincent; Blanchon, Loïc

    2014-08-01

    DNA methylation is an epigenetic mark involved in the control of genes expression. Abnormal epigenetic events have been reported in human pathologies but weakly documented in eye diseases. The purpose of this study was to establish DNMT mRNA and protein expression levels in the anterior eye segment tissues and their related (primary or immortalized) cell cultures as a first step towards future in vivo and in vitro methylomic studies. Total mRNA was extracted from human cornea, conjunctiva, anterior lens capsule, trabeculum and related cell cultures (cornea epithelial, trabecular meshwork, keratocytes for primary cells; and HCE, Chang, B-3 for immortalized cells). cDNA was quantified by real-time PCR using specific primers for DNMT1, 2, 3A, 3B and 3L. Immunolocalization assays were carried out on human cornea using specific primary antibodies for DNMT1, 2 and 3A, 3B and 3L. All DNMT transcripts were detected in human cornea, conjunctiva, anterior lens capsule, trabeculum and related cells but showed statistically different expression patterns between tissues and cells. DNMT2 protein presented a specific and singular expression pattern in corneal endothelium. This study produced the first inventory of the expression patterns of DNMTs in human adult anterior eye segment. Our research highlights that DNA methylation cannot be ruled out as a way to bring new insights into well-known ocular diseases. In addition, future DNA methylation studies using various cells as experimental models need to be conducted with attention to approach the results analysis from a global tissue perspective. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  18. Diabetes-associated dry eye syndrome in a new humanized transgenic model of type 1 diabetes.

    Science.gov (United States)

    Imam, Shahnawaz; Elagin, Raya B; Jaume, Juan Carlos

    2013-01-01

    Patients with Type 1 Diabetes (T1D) are at high risk of developing lacrimal gland dysfunction. We have developed a new model of human T1D using double-transgenic mice carrying HLA-DQ8 diabetes-susceptibility haplotype instead of mouse MHC-class II and expressing the human beta cell autoantigen Glutamic Acid Decarboxylase in pancreatic beta cells. We report here the development of dry eye syndrome (DES) after diabetes induction in our humanized transgenic model. Double-transgenic mice were immunized with DNA encoding human GAD65, either naked or in adenoviral vectors, to induce T1D. Mice monitored for development of diabetes developed lacrimal gland dysfunction. Animals developed lacrimal gland disease (classically associated with diabetes in Non Obese Diabetic [NOD] mice and with T1D in humans) as they developed glucose intolerance and diabetes. Animals manifested obvious clinical signs of dry eye syndrome (DES), from corneal erosions to severe keratitis. Histological studies of peri-bulbar areas revealed lymphocytic infiltration of glandular structures. Indeed, infiltrative lesions were observed in lacrimal/Harderian glands within weeks following development of glucose intolerance. Lesions ranged from focal lymphocytic infiltration to complete acinar destruction. We observed a correlation between the severity of the pancreatic infiltration and the severity of the ocular disease. Our results demonstrate development of DES in association with antigen-specific insulitis and diabetes following immunization with clinically relevant human autoantigen concomitantly expressed in pancreatic beta cells of diabetes-susceptible mice. As in the NOD mouse model and as in human T1D, our animals developed diabetes-associated DES. This specific finding stresses the relevance of our model for studying these human diseases. We believe our model will facilitate studies to prevent/treat diabetes-associated DES as well as human diabetes.

  19. EyeGENE

    Data.gov (United States)

    U.S. Department of Health & Human Services — The eyeGENE® Biorepository and corresponding Database contain family history and clinical eye exam data from subjects enrolled in eyeGENE® Program coupled to...

  20. Scalable production in human cells and biochemical characterization of full-length normal and mutant huntingtin.

    Directory of Open Access Journals (Sweden)

    Bin Huang

    Full Text Available Huntingtin (Htt is a 350 kD intracellular protein, ubiquitously expressed and mainly localized in the cytoplasm. Huntington's disease (HD is caused by a CAG triplet amplification in exon 1 of the corresponding gene resulting in a polyglutamine (polyQ expansion at the N-terminus of Htt. Production of full-length Htt has been difficult in the past and so far a scalable system or process has not been established for recombinant production of Htt in human cells. The ability to produce Htt in milligram quantities would be a prerequisite for many biochemical and biophysical studies aiming in a better understanding of Htt function under physiological conditions and in case of mutation and disease. For scalable production of full-length normal (17Q and mutant (46Q and 128Q Htt we have established two different systems, the first based on doxycycline-inducible Htt expression in stable cell lines, the second on "gutless" adenovirus mediated gene transfer. Purified material has then been used for biochemical characterization of full-length Htt. Posttranslational modifications (PTMs were determined and several new phosphorylation sites were identified. Nearly all PTMs in full-length Htt localized to areas outside of predicted alpha-solenoid protein regions. In all detected N-terminal peptides methionine as the first amino acid was missing and the second, alanine, was found to be acetylated. Differences in secondary structure between normal and mutant Htt, a helix-rich protein, were not observed in our study. Purified Htt tends to form dimers and higher order oligomers, thus resembling the situation observed with N-terminal fragments, although the mechanism of oligomer formation may be different.

  1. Vertical eye position-dependence of the human vestibuloocular reflex during passive and active yaw head rotations.

    Science.gov (United States)

    Thurtell, M J; Black, R A; Halmagyi, G M; Curthoys, I S; Aw, S T

    1999-05-01

    Vertical eye position-dependence of the human vestibuloocular reflex during passive and active yaw head rotations. The effect of vertical eye-in-head position on the compensatory eye rotation response to passive and active high acceleration yaw head rotations was examined in eight normal human subjects. The stimuli consisted of brief, low amplitude (15-25 degrees ), high acceleration (4,000-6,000 degrees /s2) yaw head rotations with respect to the trunk (peak velocity was 150-350 degrees /s). Eye and head rotations were recorded in three-dimensional space using the magnetic search coil technique. The input-output kinematics of the three-dimensional vestibuloocular reflex (VOR) were assessed by finding the difference between the inverted eye velocity vector and the head velocity vector (both referenced to a head-fixed coordinate system) as a time series. During passive head impulses, the head and eye velocity axes aligned well with each other for the first 47 ms after the onset of the stimulus, regardless of vertical eye-in-head position. After the initial 47-ms period, the degree of alignment of the eye and head velocity axes was modulated by vertical eye-in-head position. When fixation was on a target 20 degrees up, the eye and head velocity axes remained well aligned with each other. However, when fixation was on targets at 0 and 20 degrees down, the eye velocity axis tilted forward relative to the head velocity axis. During active head impulses, the axis tilt became apparent within 5 ms of the onset of the stimulus. When fixation was on a target at 0 degrees, the velocity axes remained well aligned with each other. When fixation was on a target 20 degrees up, the eye velocity axis tilted backward, when fixation was on a target 20 degrees down, the eye velocity axis tilted forward. The findings show that the VOR compensates very well for head motion in the early part of the response to unpredictable high acceleration stimuli-the eye position- dependence of the

  2. Human microcephaly protein RTTN interacts with STIL and is required to build full-length centrioles.

    Science.gov (United States)

    Chen, Hsin-Yi; Wu, Chien-Ting; Tang, Chieh-Ju C; Lin, Yi-Nan; Wang, Won-Jing; Tang, Tang K

    2017-08-15

    Mutations in many centriolar protein-encoding genes cause primary microcephaly. Using super-resolution and electron microscopy, we find that the human microcephaly protein, RTTN, is recruited to the proximal end of the procentriole at early S phase, and is located at the inner luminal walls of centrioles. Further studies demonstrate that RTTN directly interacts with STIL and acts downstream of STIL-mediated centriole assembly. CRISPR/Cas9-mediated RTTN gene knockout in p53-deficient cells induce amplification of primitive procentriole bodies that lack the distal-half centriolar proteins, POC5 and POC1B. Additional analyses show that RTTN serves as an upstream effector of CEP295, which mediates the loading of POC1B and POC5 to the distal-half centrioles. Interestingly, the naturally occurring microcephaly-associated mutant, RTTN (A578P), shows a low affinity for STIL binding and blocks centriole assembly. These findings reveal that RTTN contributes to building full-length centrioles and illuminate the molecular mechanism through which the RTTN (A578P) mutation causes primary microcephaly.Mutations in many centriolar protein-encoding genes cause primary microcephaly. Here the authors show that human microcephaly protein RTTN directly interacts with STIL and acts downstream of STIL-mediated centriole assembly, contributing to building full-length centrioles.

  3. Defining the Human Macula Transcriptome and Candidate Retinal Disease Genes UsingEyeSAGE

    Science.gov (United States)

    Rickman, Catherine Bowes; Ebright, Jessica N.; Zavodni, Zachary J.; Yu, Ling; Wang, Tianyuan; Daiger, Stephen P.; Wistow, Graeme; Boon, Kathy; Hauser, Michael A.

    2009-01-01

    Purpose To develop large-scale, high-throughput annotation of the human macula transcriptome and to identify and prioritize candidate genes for inherited retinal dystrophies, based on ocular-expression profiles using serial analysis of gene expression (SAGE). Methods Two human retina and two retinal pigment epithelium (RPE)/choroid SAGE libraries made from matched macula or midperipheral retina and adjacent RPE/choroid of morphologically normal 28- to 66-year-old donors and a human central retina longSAGE library made from 41- to 66-year-old donors were generated. Their transcription profiles were entered into a relational database, EyeSAGE, including microarray expression profiles of retina and publicly available normal human tissue SAGE libraries. EyeSAGE was used to identify retina- and RPE-specific and -associated genes, and candidate genes for retina and RPE disease loci. Differential and/or cell-type specific expression was validated by quantitative and single-cell RT-PCR. Results Cone photoreceptor-associated gene expression was elevated in the macula transcription profiles. Analysis of the longSAGE retina tags enhanced tag-to-gene mapping and revealed alternatively spliced genes. Analysis of candidate gene expression tables for the identified Bardet-Biedl syndrome disease gene (BBS5) in the BBS5 disease region table yielded BBS5 as the top candidate. Compelling candidates for inherited retina diseases were identified. Conclusions The EyeSAGE database, combining three different gene-profiling platforms including the authors’ multidonor-derived retina/RPE SAGE libraries and existing single-donor retina/RPE libraries, is a powerful resource for definition of the retina and RPE transcriptomes. It can be used to identify retina-specific genes, including alternatively spliced transcripts and to prioritize candidate genes within mapped retinal disease regions. PMID:16723438

  4. Pulp regeneration in a full-length human tooth root using a hierarchical nanofibrous microsphere system.

    Science.gov (United States)

    Li, Xiangwei; Ma, Chi; Xie, Xiaohua; Sun, Hongchen; Liu, Xiaohua

    2016-04-15

    While pulp regeneration using tissue engineering strategy has been explored for over a decade, successful regeneration of pulp tissues in a full-length human root with a one-end seal that truly simulates clinical endodontic treatment has not been achieved. To address this challenge, we designed and synthesized a unique hierarchical growth factor-loaded nanofibrous microsphere scaffolding system. In this system, vascular endothelial growth factor (VEGF) binds with heparin and is encapsulated in heparin-conjugated gelatin nanospheres, which are further immobilized in the nanofibers of an injectable poly(l-lactic acid) (PLLA) microsphere. This hierarchical microsphere system not only protects the VEGF from denaturation and degradation, but also provides excellent control of its sustained release. In addition, the nanofibrous PLLA microsphere integrates the extracellular matrix-mimicking architecture with a highly porous injectable form, efficiently accommodating dental pulp stem cells (DPSCs) and supporting their proliferation and pulp tissue formation. Our in vivo study showed the successful regeneration of pulp-like tissues that fulfilled the entire apical and middle thirds and reached the coronal third of the full-length root canal. In addition, a large number of blood vessels were regenerated throughout the canal. For the first time, our work demonstrates the success of pulp tissue regeneration in a full-length root canal, making it a significant step toward regenerative endodontics. The regeneration of pulp tissues in a full-length tooth root canal has been one of the greatest challenges in the field of regenerative endodontics, and one of the biggest barriers for its clinical application. In this study, we developed a unique approach to tackle this challenge, and for the first time, we successfully regenerated living pulp tissues in a full-length root canal, making it a significant step toward regenerative endodontics. This study will make positive scientific

  5. Lens artifacts in human fetal eyes - the challenge of interpreting the histomorphology of human fetal lenses.

    Science.gov (United States)

    Herwig, Martina C; Müller, Annette M; Klarmann-Schulz, Ute; Holz, Frank G; Loeffler, Karin U

    2014-01-01

    Evaluation of the lens, including cataractous changes, is often of paramount importance in the classification of fetal syndromes or forensic questions. On histology, the crystalline lens is - especially in fetal and infant eyes - an organ susceptible to numerous artifacts. Thus, the aim of our study was to study various factors (including fixatives) that might have an impact on lens histomorphology. Twenty eyes from ten fetuses (formalin fixation: n = 10, glutaraldehyde fixation: n = 10), matched for gestational age and abortion (spontaneous vs. induced), were investigated macroscopically and by light microscopy. Sections were stained with routine hematoxylin & eosin (H&E), and periodic acid schiff (PAS). The age of the fetal eyes ranged from 15 to 36 weeks of gestation. Lens artifacts were analyzed and compared to fetal and adult lenses with definitive cataractous changes. In addition, 34 eyes from 27 fetuses with trisomy 21 were investigated for lens changes. All lenses showed artifacts of varying extent, in particular globules, vacuoles, clefts, anterior/posterior capsular separation, subcapsular proteinaceous material, fragmentation of the lens capsule/epithelium, and a posterior umbilication. Glutaraldehyde-fixed lenses displayed less artifacts compared to those fixed in formalin. Slight differences in the appearance of artifacts were found dependent on the fixative (formaldehyde vs glutaraldehyde) and the kind of abortion (iatrogenous vs spontaneous). The gestational age did not have a significant influence on the type and extent of lens artifacts. The lenses from fetuses with trisomy 21 displayed similar lens artifacts with no specific findings. Alterations in fetal lens morphology are extremely frequent and variable. These artifacts have to be carefully taken into account when interpreting post-mortem findings. Thus, the postmortem diagnosis of a fetal cataract should be made with great caution, and should include, in adherence to our proposed

  6. Application of fluorescent amplified fragment length polymorphism for comparison of human and animal isolates of Yersinia enterocolitica

    DEFF Research Database (Denmark)

    Fearnley, C.; On, S.L.W.; Kokotovic, Branko

    2005-01-01

    An amplified fragment length polymorphism (AFLP) method, developed to genotype Yersinia enterocolitica, has been used to investigate 70 representative strains isolated from humans, pigs, sheep, and cattle in the United Kingdom. AFLP primarily distinguished Y enterocolitica strains according...

  7. Postural And Eye-Positional Effects On Human Biting Force: An Experimental Study

    Directory of Open Access Journals (Sweden)

    Altay Tabancacı

    2012-06-01

    Full Text Available Muscle groups affected on biting force are called temporal muscle as a major and masseter muscle as a minor. According to the human posture stability, forces of these muscles vary with the force directions. In this case, experimental investigation is strictly important such that biting force under different postural and eye- positional situations is changed. In this study, seven-male and seven-female within the age-range of 17-24 are considered corresponding to having with restorated molar tooth and without that type of tooth. With the help of specially designed biting fork, different posture- and eye-positions are investigated for experimental biting force analysis. Changes in eye-positions are not indicated significant difference for all postural positions. On one hand, it is obtained that biting force of no-filling tooth in men becomes maximum if facial muscles give full effort to biting. On the other hand, effect of facial muscles for women is not clearly noticed depending on the postural differences.

  8. FDTD computation of human eye exposure to ultra-wideband electromagnetic pulses

    Energy Technology Data Exchange (ETDEWEB)

    Simicevic, Neven [Center for Applied Physics Studies, Louisiana Tech University, Ruston, LA 71272 (United States)], E-mail: neven@phys.latech.edu

    2008-03-21

    With an increase in the application of ultra-wideband (UWB) electromagnetic pulses in the communications industry, radar, biotechnology and medicine, comes an interest in UWB exposure safety standards. Despite an increase of the scientific research on bioeffects of exposure to non-ionizing UWB pulses, characterization of those effects is far from complete. A numerical computational approach, such as a finite-difference time domain (FDTD) method, is required to visualize and understand the complexity of broadband electromagnetic interactions. The FDTD method has almost no limits in the description of the geometrical and dispersive properties of the simulated material, it is numerically robust and appropriate for current computer technology. In this paper, a complete calculation of exposure of the human eye to UWB electromagnetic pulses in the frequency range of 3.1-10.6, 22-29 and 57-64 GHz is performed. Computation in this frequency range required a geometrical resolution of the eye of 0.1 mm and an arbitrary precision in the description of its dielectric properties in terms of the Debye model. New results show that the interaction of UWB pulses with the eye tissues exhibits the same properties as the interaction of the continuous electromagnetic waves (CWs) with the frequencies from the pulse's frequency spectrum. It is also shown that under the same exposure conditions the exposure to UWB pulses is from one to many orders of magnitude safer than the exposure to CW.

  9. FDTD computation of human eye exposure to ultra-wideband electromagnetic pulses.

    Science.gov (United States)

    Simicevic, Neven

    2008-03-21

    With an increase in the application of ultra-wideband (UWB) electromagnetic pulses in the communications industry, radar, biotechnology and medicine, comes an interest in UWB exposure safety standards. Despite an increase of the scientific research on bioeffects of exposure to non-ionizing UWB pulses, characterization of those effects is far from complete. A numerical computational approach, such as a finite-difference time domain (FDTD) method, is required to visualize and understand the complexity of broadband electromagnetic interactions. The FDTD method has almost no limits in the description of the geometrical and dispersive properties of the simulated material, it is numerically robust and appropriate for current computer technology. In this paper, a complete calculation of exposure of the human eye to UWB electromagnetic pulses in the frequency range of 3.1-10.6, 22-29 and 57-64 GHz is performed. Computation in this frequency range required a geometrical resolution of the eye of 0.1 mm and an arbitrary precision in the description of its dielectric properties in terms of the Debye model. New results show that the interaction of UWB pulses with the eye tissues exhibits the same properties as the interaction of the continuous electromagnetic waves (CWs) with the frequencies from the pulse's frequency spectrum. It is also shown that under the same exposure conditions the exposure to UWB pulses is from one to many orders of magnitude safer than the exposure to CW.

  10. FDTD computation of human eye exposure to ultra-wideband electromagnetic pulses

    International Nuclear Information System (INIS)

    Simicevic, Neven

    2008-01-01

    With an increase in the application of ultra-wideband (UWB) electromagnetic pulses in the communications industry, radar, biotechnology and medicine, comes an interest in UWB exposure safety standards. Despite an increase of the scientific research on bioeffects of exposure to non-ionizing UWB pulses, characterization of those effects is far from complete. A numerical computational approach, such as a finite-difference time domain (FDTD) method, is required to visualize and understand the complexity of broadband electromagnetic interactions. The FDTD method has almost no limits in the description of the geometrical and dispersive properties of the simulated material, it is numerically robust and appropriate for current computer technology. In this paper, a complete calculation of exposure of the human eye to UWB electromagnetic pulses in the frequency range of 3.1-10.6, 22-29 and 57-64 GHz is performed. Computation in this frequency range required a geometrical resolution of the eye of 0.1 mm and an arbitrary precision in the description of its dielectric properties in terms of the Debye model. New results show that the interaction of UWB pulses with the eye tissues exhibits the same properties as the interaction of the continuous electromagnetic waves (CWs) with the frequencies from the pulse's frequency spectrum. It is also shown that under the same exposure conditions the exposure to UWB pulses is from one to many orders of magnitude safer than the exposure to CW

  11. Optics of the human cornea influence the accuracy of stereo eye-tracking methods: a simulation study.

    Science.gov (United States)

    Barsingerhorn, A D; Boonstra, F N; Goossens, H H L M

    2017-02-01

    Current stereo eye-tracking methods model the cornea as a sphere with one refractive surface. However, the human cornea is slightly aspheric and has two refractive surfaces. Here we used ray-tracing and the Navarro eye-model to study how these optical properties affect the accuracy of different stereo eye-tracking methods. We found that pupil size, gaze direction and head position all influence the reconstruction of gaze. Resulting errors range between ± 1.0 degrees at best. This shows that stereo eye-tracking may be an option if reliable calibration is not possible, but the applied eye-model should account for the actual optics of the cornea.

  12. The Way Dogs (Canis familiaris Look at Human Emotional Faces Is Modulated by Oxytocin. An Eye-Tracking Study

    Directory of Open Access Journals (Sweden)

    Anna Kis

    2017-10-01

    Full Text Available Dogs have been shown to excel in reading human social cues, including facial cues. In the present study we used eye-tracking technology to further study dogs’ face processing abilities. It was found that dogs discriminated between human facial regions in their spontaneous viewing pattern and looked most to the eye region independently of facial expression. Furthermore dogs played most attention to the first two images presented, afterwards their attention dramatically decreases; a finding that has methodological implications. Increasing evidence indicates that the oxytocin system is involved in dogs’ human-directed social competence, thus as a next step we investigated the effects of oxytocin on processing of human facial emotions. It was found that oxytocin decreases dogs’ looking to the human faces expressing angry emotional expression. More interestingly, however, after oxytocin pre-treatment dogs’ preferential gaze toward the eye region when processing happy human facial expressions disappears. These results provide the first evidence that oxytocin is involved in the regulation of human face processing in dogs. The present study is one of the few empirical investigations that explore eye gaze patterns in naïve and untrained pet dogs using a non-invasive eye-tracking technique and thus offers unique but largely untapped method for studying social cognition in dogs.

  13. Femtosecond laser-induced cavitations in the lens of the human eye

    DEFF Research Database (Denmark)

    Kessel, Line; Nymand, Jose; Harbst, Michael

    2007-01-01

    attempted to define the cavitation threshold in the human lens in vitro using multiphoton effects base d on radiation from a femtosecond 800 nm Ti:Sapphire laser. Cavitations were observed from pulse energy densities exceeding 16 mJ/cm2, but only after several minutes of exposure and not as a result...... laser effects in the len s that have a potential for therapeutic application and treatment of eye dis ease though further studies are needed to shed light on the nature of the formation of delayed cavitations....

  14. Towards Quantum Experiments with Human Eyes as Detectors Based on Cloning via Stimulated Emission

    Science.gov (United States)

    Sekatski, Pavel; Brunner, Nicolas; Branciard, Cyril; Gisin, Nicolas; Simon, Christoph

    2009-09-01

    We show theoretically that a large Bell inequality violation can be obtained with human eyes as detectors, in a “micro-macro” experiment where one photon from an entangled pair is greatly amplified via stimulated emission. The violation is robust under photon loss. This leads to an apparent paradox, which we resolve by noting that the violation proves the existence of entanglement before the amplification. The same is true for the micro-macro experiments performed so far with conventional detectors. However, we also prove that there is genuine micro-macro entanglement even for high loss.

  15. Ofd1, a human disease gene, regulates the length and distal structure of centrioles.

    Science.gov (United States)

    Singla, Veena; Romaguera-Ros, Miriam; Garcia-Verdugo, Jose Manuel; Reiter, Jeremy F

    2010-03-16

    Centrosomes and their component centrioles represent the principal microtubule organizing centers of animal cells. Here, we show that the gene underlying orofaciodigital syndrome 1, Ofd1, is a component of the distal centriole that controls centriole length. In the absence of Ofd1, distal regions of centrioles, but not procentrioles, elongate abnormally. These long centrioles are structurally similar to normal centrioles but contain destabilized microtubules with abnormal posttranslational modifications. Ofd1 is also important for centriole distal appendage formation and centriolar recruitment of the intraflagellar transport protein Ift88. To model OFD1 syndrome in embryonic stem cells, we replaced the Ofd1 gene with missense alleles from human OFD1 patients. Distinct disease-associated mutations cause different degrees of excessive or decreased centriole elongation, all of which are associated with diminished ciliogenesis. Our results indicate that Ofd1 acts at the distal centriole to build distal appendages, recruit Ift88, and stabilize centriolar microtubules at a defined length. Copyright 2010 Elsevier Inc. All rights reserved.

  16. Evaluation of Eye Irritation Potential of Solid Substance with New 3D Reconstructed Human Cornea Model, MCTT HCE(TM).

    Science.gov (United States)

    Jang, Won-Hee; Jung, Kyoung-Mi; Yang, Hye-Ri; Lee, Miri; Jung, Haeng-Sun; Lee, Su-Hyon; Park, Miyoung; Lim, Kyung-Min

    2015-07-01

    The eye irritation potential of drug candidates or pharmaceutical ingredients should be evaluated if there is a possibility of ocular exposure. Traditionally, the ocular irritation has been evaluated by the rabbit Draize test. However, rabbit eyes are more sensitive to irritants than human eyes, therefore substantial level of false positives are unavoidable. To resolve this species difference, several three-dimensional human corneal epithelial (HCE) models have been developed as alternative eye irritation test methods. Recently, we introduced a new HCE model, MCTT HCE(TM) which is reconstructed with non-transformed human corneal cells from limbal tissues. Here, we examined if MCTT HCE(TM) can be employed to evaluate eye irritation potential of solid substances. Through optimization of washing method and exposure time, treatment time was established as 10 min and washing procedure was set up as 4 times of washing with 10 mL of PBS and shaking in 30 mL of PBS in a beaker. With the established eye irritation test protocol, 11 solid substances (5 non-irritants, 6 irritants) were evaluated which demonstrated an excellent predictive capacity (100% accuracy, 100% specificity and 100% sensitivity). We also compared the performance of our test method with rabbit Draize test results and in vitro cytotoxicity test with 2D human corneal epithelial cell lines.

  17. Molecular mechanism of ocular surface damage: application to an in vitro dry eye model on human corneal epithelium.

    Science.gov (United States)

    Meloni, Marisa; De Servi, Barbara; Marasco, Daniela; Del Prete, Salvatore

    2011-01-12

    The present study was concerned with the development of a new experimental model of dry eye using human reconstructed in vitro corneal epithelium (HCE). The model is based on the use of adapted culture conditions that induce relevant modifications at the cellular and molecular level thus mimicking dry eye. The HCE model was maintained in a controlled environmental setting (relative humidity eye. The evolution of the dry eye condition was assessed by histology, immunohistochemistry staining, scanning electron microscopy, and gene expression by using TaqMan gene assay technology (mucin-4 [MUC4], matrix metallopeptidase-9 [MMP9], tumor necrosis factor-α [TNF-α], and defensin β-2 [DEFB2). The effects of different commercially available tear substitutes on the induced dry eye condition were tested. This in vitro dry eye HCE model, that was well established within 24 h, has the characteristic features of a dry eye epithelium and could be satisfactorily used for preliminary assessment of the protective activity of some artificial tears. The transcriptional study of selected biomarkers showed an increase in MUC4, MMP9, TNF-α, and hBD-2 (DEFB2) gene expression. By using a dynamic approach, we were able to define a biomarker gene signature of dry eye-induced effects that could be predictive of corneal damage in vivo and to discriminate the efficacy among different commercial artificial tears.

  18. Gold nanoparticle-based brachytherapy enhancement in choroidal melanoma using a full Monte Carlo model of the human eye.

    Science.gov (United States)

    Asadi, Somayeh; Vaez-zadeh, Mehdi; Masoudi, S Farhad; Rahmani, Faezeh; Knaup, Courtney; Meigooni, Ali S

    2015-09-08

    The effects of gold nanoparticles (GNPs) in 125I brachytherapy dose enhancement on choroidal melanoma are examined using the Monte Carlo simulation technique. Usually, Monte Carlo ophthalmic brachytherapy dosimetry is performed in a water phantom. However, here, the compositions of human eye have been considered instead of water. Both human eye and water phantoms have been simulated with MCNP5 code. These simulations were performed for a fully loaded 16 mm COMS eye plaque containing 13 125I seeds. The dose delivered to the tumor and normal tissues have been calculated in both phantoms with and without GNPs. Normally, the radiation therapy of cancer patients is designed to deliver a required dose to the tumor while sparing the surrounding normal tissues. However, as the normal and cancerous cells absorbed dose in an almost identical fashion, the normal tissue absorbed radiation dose during the treatment time. The use of GNPs in combination with radiotherapy in the treatment of tumor decreases the absorbed dose by normal tissues. The results indicate that the dose to the tumor in an eyeball implanted with COMS plaque increases with increasing GNPs concentration inside the target. Therefore, the required irradiation time for the tumors in the eye is decreased by adding the GNPs prior to treatment. As a result, the dose to normal tissues decreases when the irradiation time is reduced. Furthermore, a comparison between the simulated data in an eye phantom made of water and eye phantom made of human eye composition, in the presence of GNPs, shows the significance of utilizing the composition of eye in ophthalmic brachytherapy dosimetry Also, defining the eye composition instead of water leads to more accurate calculations of GNPs radiation effects in ophthalmic brachytherapy dosimetry.

  19. LASIK eye surgery

    Science.gov (United States)

    ... Assisted In Situ Keratomileusis; Laser vision correction; Nearsightedness - Lasik; Myopia - Lasik ... cornea (curvature) and the length of the eye. LASIK uses an excimer laser (an ultraviolet laser) to ...

  20. Telomere length differences between subcutaneous and visceral adipose tissue in humans

    International Nuclear Information System (INIS)

    Lakowa, Nicole; Trieu, Nhu; Flehmig, Gesine; Lohmann, Tobias; Schön, Michael R.; Dietrich, Arne; Zeplin, Philip Helge; Langer, Stefan; Stumvoll, Michael; Blüher, Matthias; Klöting, Nora

    2015-01-01

    Adipocyte hypertrophy and hyperplasia have been shown to be associated with shorter telomere length, which may reflect aging, altered cell proliferation and adipose tissue (AT) dysfunction. In individuals with obesity, differences in fat distribution and AT cellular composition may contribute to obesity related metabolic diseases. Here, we tested the hypotheses that telomere lengths (TL) are different between: (1) abdominal subcutaneous and omental fat depots, (2) superficial and deep abdominal subcutaneous AT (SAT), and (3) adipocytes and cells of the stromal vascular fraction (SVF). We further asked whether AT TL is related to age, anthropometric and metabolic traits. TL was analyzed by quantitative PCR in total human genomic DNA isolated from paired subcutaneous and visceral AT of 47 lean and 50 obese individuals. In subgroups, we analyzed TL in isolated small and large adipocytes and SVF cells. We find significantly shorter TL in subcutaneous compared to visceral AT (P < 0.001) which is consistent in men and subgroups of lean and obese, and individuals with or without type 2 diabetes (T2D). Shorter TL in SAT is entirely due to shorter TL in the SVF compared to visceral AT (P < 0.01). SAT TL is most strongly correlated with age (r = −0.205, P < 0.05) and independently of age with HbA1c (r = −0.5, P < 0.05). We found significant TL differences between superficial SAT of lean and obese as well as between individuals with our without T2D, but not between the two layers of SAT. Our data indicate that fat depot differences in TL mainly reflect shorter TL of SVF cells. In addition, we found an age and BMI-independent relationship between shorter TL and HbA1c suggesting that chronic hyperglycemia may impair the regenerative capacity of AT more strongly than obesity alone. - Highlights: • Telomere lengths (TL) differ between fat depots mainly due to different lengths in SVF. • TL is not associated with gender, BMI and T2D. • The tendency for

  1. Telomere length differences between subcutaneous and visceral adipose tissue in humans

    Energy Technology Data Exchange (ETDEWEB)

    Lakowa, Nicole; Trieu, Nhu; Flehmig, Gesine [Department of Medicine, University of Leipzig, Leipzig (Germany); Lohmann, Tobias [Municipal Clinic Dresden-Neustadt, Dresden (Germany); Schön, Michael R. [Städtisches Klinikum Karlsruhe, Clinic of Visceral Surgery, Karlsruhe (Germany); Dietrich, Arne [Department of Surgery, University of Leipzig, Leipzig (Germany); IFB AdiposityDiseases, University of Leipzig, Leipzig (Germany); Zeplin, Philip Helge; Langer, Stefan [Department of Orthopaedics, Traumatology and Plastic Surgery, University of Leipzig, Leipzig (Germany); Stumvoll, Michael; Blüher, Matthias [Department of Medicine, University of Leipzig, Leipzig (Germany); Klöting, Nora, E-mail: nora.kloeting@medizin.uni-leipzig.de [IFB AdiposityDiseases, Junior Research Group 2 “Animal Models of Obesity”, University of Leipzig, Leipzig (Germany)

    2015-02-13

    Adipocyte hypertrophy and hyperplasia have been shown to be associated with shorter telomere length, which may reflect aging, altered cell proliferation and adipose tissue (AT) dysfunction. In individuals with obesity, differences in fat distribution and AT cellular composition may contribute to obesity related metabolic diseases. Here, we tested the hypotheses that telomere lengths (TL) are different between: (1) abdominal subcutaneous and omental fat depots, (2) superficial and deep abdominal subcutaneous AT (SAT), and (3) adipocytes and cells of the stromal vascular fraction (SVF). We further asked whether AT TL is related to age, anthropometric and metabolic traits. TL was analyzed by quantitative PCR in total human genomic DNA isolated from paired subcutaneous and visceral AT of 47 lean and 50 obese individuals. In subgroups, we analyzed TL in isolated small and large adipocytes and SVF cells. We find significantly shorter TL in subcutaneous compared to visceral AT (P < 0.001) which is consistent in men and subgroups of lean and obese, and individuals with or without type 2 diabetes (T2D). Shorter TL in SAT is entirely due to shorter TL in the SVF compared to visceral AT (P < 0.01). SAT TL is most strongly correlated with age (r = −0.205, P < 0.05) and independently of age with HbA1c (r = −0.5, P < 0.05). We found significant TL differences between superficial SAT of lean and obese as well as between individuals with our without T2D, but not between the two layers of SAT. Our data indicate that fat depot differences in TL mainly reflect shorter TL of SVF cells. In addition, we found an age and BMI-independent relationship between shorter TL and HbA1c suggesting that chronic hyperglycemia may impair the regenerative capacity of AT more strongly than obesity alone. - Highlights: • Telomere lengths (TL) differ between fat depots mainly due to different lengths in SVF. • TL is not associated with gender, BMI and T2D. • The tendency for

  2. The digital aqueous humor outflow meter: an alternative tool for screening of the human eye outflow facility

    Directory of Open Access Journals (Sweden)

    Vassilios P Kozobolis

    2010-08-01

    Full Text Available Vassilios P Kozobolis, Eleftherios I Paschalis, Nikitas C Foudoulakis, Stavrenia C Koukoula, Georgios LabirisDepartment of Ophthalmology and Eye Institute of Thrace, Democritus University of Thrace, Alexandroupolis, GreecePurpose: To develop, characterize, and validate a prototype digital aqueous humor outflow tonographer (DAHOM.Material and methods: The DAHOM was developed, characterized, and validated in three phases. Phase 1 involved construction of the sensor. This was broadly based on the fundamental design of a typical Schiotz tonographer with a series of improvements, including corneal indentation, which was converted to an electrical signal via a linear variable differential transducer, an analog signal which was converted to digital via ADC circuitry, and digital data acquisition and processing which was made possible by a serial port interface. Phase 2 comprised development of software for automated assessment of the outflow facility. Automated outflow facility assessment incorporated a series of fundamental improvements in comparison with traditional techniques, including software-based filtering of ripple noise and extreme variations, rigidity impact analysis, and evaluation of the impact of patient age, central corneal thickness, and ocular axial length. Phase 3 comprised characterization and validation of DAHOM, for which we developed an experimental setup using porcine cadaver eyes. DAHOM’s repeatability was evaluated by means of Cronbach’s alpha and intraclass correlation coefficient. The level of agreement with a standard Schiotz tonographer was evaluated by means of paired t-tests and Bland-Altman analysis in human eyes.Results: The experimental setup provided the necessary data for the characterization of DAHOM. A fourth order polynomial equation provided excellent fit (R square >0.999. DAHOM demonstrated high repeatability (Cronbach’s alpha ≥0.997; intraclass correlation coefficient ≥0.987 and an adequate level of

  3. Does the foveal shape influence the image formation in human eyes?

    Science.gov (United States)

    Frey, Katharina; Zimmerling, Beatrice; Scheibe, Patrick; Rauscher, Franziska G.; Reichenbach, Andreas; Francke, Mike; Brunner, Robert

    2017-10-01

    In human eyes, the maximum visual acuity correlates locally with the fovea, a shallow depression in the retina. Previous examinations have been reduced to simple geometrical fovea models derived from postmortem preparations and considering only a few superficial ray propagation aspects. In the current study, an extended and realistic analysis of ray-optical simulations for a comprehensive anatomical realistic eye model for the anterior part and realistic aspherical human foveal topographical profiles deduced from in vivo optical coherence tomography (OCT) are presented, and the refractive index step at the transition from vitreous to retinal tissue is taken into account. The optical effect of a commonly shaped (averaged) and an extraordinarily shaped foveal pit were both compared to the analysis of an assumed pure spherical boundary layer. The influence of the aperture size, wavelength, and incident angle on the spot size and shape, as well as the axial focal and lateral centroid position is investigated, and a lateral displacement of about 2 μm and an axial shift of the best focal position of less than 4 μm are found. These findings indicate only small optical effects that are laterally in the range of inter-receptor distances and axially less than the photoreceptor outer segment dimension.

  4. [Profile of human milk bank donors and relationship with the length of the donation].

    Science.gov (United States)

    Sierra Colomina, G; García Lara, N; Escuder Vieco, D; Vázquez Román, S; Cabañes Alonso, E; Pallás Alonso, C R

    2014-04-01

    The promotion of Human Milk Banks is an important social service. The Human Milk Banks depend on donors, and knowing the profile of donors seems quite important. To study the demographics and lifestyles of the donors, the reasons or influences for donating, and to associate these variables with the length of the donation. This is a descriptive, cross-sectional study conducted on 168 mothers who answered the written questionnaire when they agreed to become donors. 98 (58%) responded to the telephone interview. The mean age was 33.1 ± 4.5 years. Of the total 27.9% lived outside Madrid and 21.4% were immigrants, with 23.7% working full time, 65.3% had a university education, and 96.2% had a stable partner. The main reasons for donating were too much milk (77%), and to help others (75%). The main obstacle was transportation to the Human Milk Bank for 20% of the donors, and for 61% the main reason for terminating donation was due to reaching the end of lactation. A longer donation is associated with: having a term newborn, with birth weight over 1500 g, starting donating early and reconciling the donation to the work situation. The most common donor profile was a young woman, with university education and a stable partner. Having a term new born, starting donating early, and the conciliation with work is associated with longer donations. Milk pick-up at home would make donation easier. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  5. Intraocular distribution of melanin in human, monkey, rabbit, minipig and dog eyes.

    Science.gov (United States)

    Durairaj, Chandrasekar; Chastain, James E; Kompella, Uday B

    2012-05-01

    The purpose of this study was to quantify the melanin pigment content in sclera, choroid-RPE, and retina, three tissues encountered during transscleral drug delivery to the vitreous, in human, rabbit, monkey, minipig, and dog models. Strain differences were assessed in NZW × NZR F1 and Dutch belted rabbits and Yucatan and Gottingen minipigs. The choroid-RPE and retina tissues were divided into central (posterior pole area) and peripheral (away from posterior pole) regions while the sclera was analyzed without such division. Melanin content in the tissues was analyzed using a colorimetric assay. In all species the rank order for pigment content was: choroid-RPE >retina ≥ sclera, except in humans, where scleral melanin levels were higher than retina and central choroid. The melanin content in a given tissue differed between species. Further, while the peripheral tissue pigment levels tended to be generally higher compared to the central regions, these differences were significant in human in the case of choroid-RPE and in human, monkey, and dogs in the case of retina. Strain difference was observed only in the central choroid-RPE region of rabbits (NZW × NZR F1 >Dutch Belted). Species, strain, and regional differences exist in the melanin pigment content in the tissues of the posterior segment of the eye, with Gottingen minipig being closest to humans among the animals assessed. These differences in melanin content might contribute to differences in drug binding, delivery, and toxicity. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Potency of full-length MGF to induce maximal activation of the IGF-I R Is similar to recombinant human IGF-I at high equimolar concentrations

    NARCIS (Netherlands)

    J.A.M.J.L. Janssen (Joseph); L.J. Hofland (Leo); C.J. Strasburger; E.S.R.D. Van Dungen (Elisabeth S.R. Den); M. Thevis (Mario)

    2016-01-01

    textabstractAims To compare full-length mechano growth factor (full-length MGF) with human recombinant insulin-like growth factor-I (IGF-I) and human recombinant insulin (HI) in their ability to activate the human IGF-I receptor (IGF-IR), the human insulin receptor (IR-A) and the human insulin

  7. Measuring higher order optical aberrations of the human eye: techniques and applications

    Directory of Open Access Journals (Sweden)

    L. Alberto V. Carvalho

    2002-11-01

    Full Text Available In the present paper we discuss the development of "wave-front", an instrument for determining the lower and higher optical aberrations of the human eye. We also discuss the advantages that such instrumentation and techniques might bring to the ophthalmology professional of the 21st century. By shining a small light spot on the retina of subjects and observing the light that is reflected back from within the eye, we are able to quantitatively determine the amount of lower order aberrations (astigmatism, myopia, hyperopia and higher order aberrations (coma, spherical aberration, etc.. We have measured artificial eyes with calibrated ametropia ranging from +5 to -5 D, with and without 2 D astigmatism with axis at 45º and 90º. We used a device known as the Hartmann-Shack (HS sensor, originally developed for measuring the optical aberrations of optical instruments and general refracting surfaces in astronomical telescopes. The HS sensor sends information to a computer software for decomposition of wave-front aberrations into a set of Zernike polynomials. These polynomials have special mathematical properties and are more suitable in this case than the traditional Seidel polynomials. We have demonstrated that this technique is more precise than conventional autorefraction, with a root mean square error (RMSE of less than 0.1 µm for a 4-mm diameter pupil. In terms of dioptric power this represents an RMSE error of less than 0.04 D and 5º for the axis. This precision is sufficient for customized corneal ablations, among other applications.

  8. Imaging the Aqueous Humor Outflow Pathway in Human Eyes by Three-dimensional Micro-computed Tomography (3D micro-CT)

    Energy Technology Data Exchange (ETDEWEB)

    C Hann; M Bentley; A Vercnocke; E Ritman; M Fautsch

    2011-12-31

    The site of outflow resistance leading to elevated intraocular pressure in primary open-angle glaucoma is believed to be located in the region of Schlemm's canal inner wall endothelium, its basement membrane and the adjacent juxtacanalicular tissue. Evidence also suggests collector channels and intrascleral vessels may have a role in intraocular pressure in both normal and glaucoma eyes. Traditional imaging modalities limit the ability to view both proximal and distal portions of the trabecular outflow pathway as a single unit. In this study, we examined the effectiveness of three-dimensional micro-computed tomography (3D micro-CT) as a potential method to view the trabecular outflow pathway. Two normal human eyes were used: one immersion fixed in 4% paraformaldehyde and one with anterior chamber perfusion at 10 mmHg followed by perfusion fixation in 4% paraformaldehyde/2% glutaraldehyde. Both eyes were postfixed in 1% osmium tetroxide and scanned with 3D micro-CT at 2 {mu}m or 5 {mu}m voxel resolution. In the immersion fixed eye, 24 collector channels were identified with an average orifice size of 27.5 {+-} 5 {mu}m. In comparison, the perfusion fixed eye had 29 collector channels with a mean orifice size of 40.5 {+-} 13 {mu}m. Collector channels were not evenly dispersed around the circumference of the eye. There was no significant difference in the length of Schlemm's canal in the immersed versus the perfused eye (33.2 versus 35.1 mm). Structures, locations and size measurements identified by 3D micro-CT were confirmed by correlative light microscopy. These findings confirm 3D micro-CT can be used effectively for the non-invasive examination of the trabecular meshwork, Schlemm's canal, collector channels and intrascleral vasculature that comprise the distal outflow pathway. This imaging modality will be useful for non-invasive study of the role of the trabecular outflow pathway as a whole unit.

  9. Influence of physical activity in length of life of the human population in the context of changes

    OpenAIRE

    Ahmetović Zlatko; Romanov Romana; Dimitrić Mirjana

    2014-01-01

    Since the middle of the last century, the human population has increased exponentially. This trend is evident today. Human population has, for more than half a century been undergoing the period of its intensive development, increasing in number and the average length of life, creating the impression of a better life standard. Looking at the man as a bio-psycho-social being and the interactions it ones through the human population growth is brought in connection with its impact on the environ...

  10. Fast ray-tracing of human eye optics on Graphics Processing Units.

    Science.gov (United States)

    Wei, Qi; Patkar, Saket; Pai, Dinesh K

    2014-05-01

    We present a new technique for simulating retinal image formation by tracing a large number of rays from objects in three dimensions as they pass through the optic apparatus of the eye to objects. Simulating human optics is useful for understanding basic questions of vision science and for studying vision defects and their corrections. Because of the complexity of computing such simulations accurately, most previous efforts used simplified analytical models of the normal eye. This makes them less effective in modeling vision disorders associated with abnormal shapes of the ocular structures which are hard to be precisely represented by analytical surfaces. We have developed a computer simulator that can simulate ocular structures of arbitrary shapes, for instance represented by polygon meshes. Topographic and geometric measurements of the cornea, lens, and retina from keratometer or medical imaging data can be integrated for individualized examination. We utilize parallel processing using modern Graphics Processing Units (GPUs) to efficiently compute retinal images by tracing millions of rays. A stable retinal image can be generated within minutes. We simulated depth-of-field, accommodation, chromatic aberrations, as well as astigmatism and correction. We also show application of the technique in patient specific vision correction by incorporating geometric models of the orbit reconstructed from clinical medical images. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  11. Ion therapy for uveal melanoma in new human eye phantom based on GEANT4 toolkit

    Energy Technology Data Exchange (ETDEWEB)

    Mahdipour, Seyed Ali [Physics Department, Hakim Sabzevari University, Sabzevar (Iran, Islamic Republic of); Mowlavi, Ali Asghar, E-mail: amowlavi@hsu.ac.ir [Physics Department, Hakim Sabzevari University, Sabzevar (Iran, Islamic Republic of); ICTP, Associate Federation Scheme, Medical Physics Field, Trieste (Italy)

    2016-07-01

    Radiotherapy with ion beams like proton and carbon has been used for treatment of eye uveal melanoma for many years. In this research, we have developed a new phantom of human eye for Monte Carlo simulation of tumors treatment to use in GEANT4 toolkit. Total depth−dose profiles for the proton, alpha, and carbon incident beams with the same ranges have been calculated in the phantom. Moreover, the deposited energy of the secondary particles for each of the primary beams is calculated. The dose curves are compared for 47.8 MeV proton, 190.1 MeV alpha, and 1060 MeV carbon ions that have the same range in the target region reaching to the center of tumor. The passively scattered spread-out Bragg peak (SOBP) for each incident beam as well as the flux curves of the secondary particles including neutron, gamma, and positron has been calculated and compared for the primary beams. The high sharpness of carbon beam's Bragg peak with low lateral broadening is the benefit of this beam in hadrontherapy but it has disadvantages of dose leakage in the tail after its Bragg peak and high intensity of neutron production. However, proton beam, which has a good conformation with tumor shape owing to the beam broadening caused by scattering, can be a good choice for the large-size tumors.

  12. Ion therapy for uveal melanoma in new human eye phantom based on GEANT4 toolkit

    International Nuclear Information System (INIS)

    Mahdipour, Seyed Ali; Mowlavi, Ali Asghar

    2016-01-01

    Radiotherapy with ion beams like proton and carbon has been used for treatment of eye uveal melanoma for many years. In this research, we have developed a new phantom of human eye for Monte Carlo simulation of tumors treatment to use in GEANT4 toolkit. Total depth−dose profiles for the proton, alpha, and carbon incident beams with the same ranges have been calculated in the phantom. Moreover, the deposited energy of the secondary particles for each of the primary beams is calculated. The dose curves are compared for 47.8 MeV proton, 190.1 MeV alpha, and 1060 MeV carbon ions that have the same range in the target region reaching to the center of tumor. The passively scattered spread-out Bragg peak (SOBP) for each incident beam as well as the flux curves of the secondary particles including neutron, gamma, and positron has been calculated and compared for the primary beams. The high sharpness of carbon beam's Bragg peak with low lateral broadening is the benefit of this beam in hadrontherapy but it has disadvantages of dose leakage in the tail after its Bragg peak and high intensity of neutron production. However, proton beam, which has a good conformation with tumor shape owing to the beam broadening caused by scattering, can be a good choice for the large-size tumors.

  13. Use of Eye Tracking as an Innovative Instructional Method in Surgical Human Anatomy.

    Science.gov (United States)

    Sánchez-Ferrer, María Luísa; Grima-Murcia, María Dolores; Sánchez-Ferrer, Francisco; Hernández-Peñalver, Ana Isabel; Fernández-Jover, Eduardo; Sánchez Del Campo, Francisco

    Tobii glasses can record corneal infrared light reflection to track pupil position and to map gaze focusing in the video recording. Eye tracking has been proposed for use in training and coaching as a visually guided control interface. The aim of our study was to test the potential use of these glasses in various situations: explanations of anatomical structures on tablet-type electronic devices, explanations of anatomical models and dissected cadavers, and during the prosection thereof. An additional aim of the study was to test the use of the glasses during laparoscopies performed on Thiel-embalmed cadavers (that allows pneumoinsufflation and exact reproduction of the laparoscopic surgical technique). The device was also tried out in actual surgery (both laparoscopy and open surgery). We performed a pilot study using the Tobii glasses. Dissection room at our School of Medicine and in the operating room at our Hospital. To evaluate usefulness, a survey was designed for use among students, instructors, and practicing physicians. The results were satisfactory, with the usefulness of this tool supported by more than 80% positive responses to most questions. There was no inconvenience for surgeons and that patient safety was ensured in the real laparoscopy. To our knowledge, this is the first publication to demonstrate the usefulness of eye tracking in practical instruction of human anatomy, as well as in teaching clinical anatomy and surgical techniques in the dissection and operating rooms. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  14. Impact of Sliding Window Length in Indoor Human Motion Modes and Pose Pattern Recognition Based on Smartphone Sensors

    Directory of Open Access Journals (Sweden)

    Gaojing Wang

    2018-06-01

    Full Text Available Human activity recognition (HAR is essential for understanding people’s habits and behaviors, providing an important data source for precise marketing and research in psychology and sociology. Different approaches have been proposed and applied to HAR. Data segmentation using a sliding window is a basic step during the HAR procedure, wherein the window length directly affects recognition performance. However, the window length is generally randomly selected without systematic study. In this study, we examined the impact of window length on smartphone sensor-based human motion and pose pattern recognition. With data collected from smartphone sensors, we tested a range of window lengths on five popular machine-learning methods: decision tree, support vector machine, K-nearest neighbor, Gaussian naïve Bayesian, and adaptive boosting. From the results, we provide recommendations for choosing the appropriate window length. Results corroborate that the influence of window length on the recognition of motion modes is significant but largely limited to pose pattern recognition. For motion mode recognition, a window length between 2.5–3.5 s can provide an optimal tradeoff between recognition performance and speed. Adaptive boosting outperformed the other methods. For pose pattern recognition, 0.5 s was enough to obtain a satisfactory result. In addition, all of the tested methods performed well.

  15. Methylation-Sensitive Amplification Length Polymorphism (MS-AFLP) Microarrays for Epigenetic Analysis of Human Genomes.

    Science.gov (United States)

    Alonso, Sergio; Suzuki, Koichi; Yamamoto, Fumiichiro; Perucho, Manuel

    2018-01-01

    Somatic, and in a minor scale also germ line, epigenetic aberrations are fundamental to carcinogenesis, cancer progression, and tumor phenotype. DNA methylation is the most extensively studied and arguably the best understood epigenetic mechanisms that become altered in cancer. Both somatic loss of methylation (hypomethylation) and gain of methylation (hypermethylation) are found in the genome of malignant cells. In general, the cancer cell epigenome is globally hypomethylated, while some regions-typically gene-associated CpG islands-become hypermethylated. Given the profound impact that DNA methylation exerts on the transcriptional profile and genomic stability of cancer cells, its characterization is essential to fully understand the complexity of cancer biology, improve tumor classification, and ultimately advance cancer patient management and treatment. A plethora of methods have been devised to analyze and quantify DNA methylation alterations. Several of the early-developed methods relied on the use of methylation-sensitive restriction enzymes, whose activity depends on the methylation status of their recognition sequences. Among these techniques, methylation-sensitive amplification length polymorphism (MS-AFLP) was developed in the early 2000s, and successfully adapted from its original gel electrophoresis fingerprinting format to a microarray format that notably increased its throughput and allowed the quantification of the methylation changes. This array-based platform interrogates over 9500 independent loci putatively amplified by the MS-AFLP technique, corresponding to the NotI sites mapped throughout the human genome.

  16. In vitro cytotoxicity of Manville Code 100 glass fibers: Effect of fiber length on human alveolar macrophages

    Directory of Open Access Journals (Sweden)

    Jones William

    2006-03-01

    Full Text Available Abstract Background Synthetic vitreous fibers (SVFs are inorganic noncrystalline materials widely used in residential and industrial settings for insulation, filtration, and reinforcement purposes. SVFs conventionally include three major categories: fibrous glass, rock/slag/stone (mineral wool, and ceramic fibers. Previous in vitro studies from our laboratory demonstrated length-dependent cytotoxic effects of glass fibers on rat alveolar macrophages which were possibly associated with incomplete phagocytosis of fibers ≥ 17 μm in length. The purpose of this study was to examine the influence of fiber length on primary human alveolar macrophages, which are larger in diameter than rat macrophages, using length-classified Manville Code 100 glass fibers (8, 10, 16, and 20 μm. It was hypothesized that complete engulfment of fibers by human alveolar macrophages could decrease fiber cytotoxicity; i.e. shorter fibers that can be completely engulfed might not be as cytotoxic as longer fibers. Human alveolar macrophages, obtained by segmental bronchoalveolar lavage of healthy, non-smoking volunteers, were treated with three different concentrations (determined by fiber number of the sized fibers in vitro. Cytotoxicity was assessed by monitoring cytosolic lactate dehydrogenase release and loss of function as indicated by a decrease in zymosan-stimulated chemiluminescence. Results Microscopic analysis indicated that human alveolar macrophages completely engulfed glass fibers of the 20 μm length. All fiber length fractions tested exhibited equal cytotoxicity on a per fiber basis, i.e. increasing lactate dehydrogenase and decreasing chemiluminescence in the same concentration-dependent fashion. Conclusion The data suggest that due to the larger diameter of human alveolar macrophages, compared to rat alveolar macrophages, complete phagocytosis of longer fibers can occur with the human cells. Neither incomplete phagocytosis nor length-dependent toxicity was

  17. Frequency-Dependent Modulation of Regional Synchrony in the Human Brain by Eyes Open and Eyes Closed Resting-States.

    Science.gov (United States)

    Song, Xiaopeng; Zhou, Shuqin; Zhang, Yi; Liu, Yijun; Zhu, Huaiqiu; Gao, Jia-Hong

    2015-01-01

    The eyes-open (EO) and eyes-closed (EC) states have differential effects on BOLD-fMRI signal dynamics, affecting both the BOLD oscillation frequency of a single voxel and the regional homogeneity (ReHo) of several neighboring voxels. To explore how the two resting-states modulate the local synchrony through different frequency bands, we decomposed the time series of each voxel into several components that fell into distinct frequency bands. The ReHo in each of the bands was calculated and compared between the EO and EC conditions. The cross-voxel correlations between the mean frequency and the overall ReHo of each voxel's original BOLD series in different brain areas were also calculated and compared between the two states. Compared with the EC state, ReHo decreased with EO in a wide frequency band of 0.01-0.25 Hz in the bilateral thalamus, sensorimotor network, and superior temporal gyrus, while ReHo increased significantly in the band of 0-0.01 Hz in the primary visual cortex, and in a higher frequency band of 0.02-0.1 Hz in the higher order visual areas. The cross-voxel correlations between the frequency and overall ReHo were negative in all the brain areas but varied from region to region. These correlations were stronger with EO in the visual network and the default mode network. Our results suggested that different frequency bands of ReHo showed different sensitivity to the modulation of EO-EC states. The better spatial consistency between the frequency and overall ReHo maps indicated that the brain might adopt a stricter frequency-dependent configuration with EO than with EC.

  18. An exploratory study on the driving method of speech synthesis based on the human eye reading imaging data

    Science.gov (United States)

    Gao, Pei-pei; Liu, Feng

    2016-10-01

    With the development of information technology and artificial intelligence, speech synthesis plays a significant role in the fields of Human-Computer Interaction Techniques. However, the main problem of current speech synthesis techniques is lacking of naturalness and expressiveness so that it is not yet close to the standard of natural language. Another problem is that the human-computer interaction based on the speech synthesis is too monotonous to realize mechanism of user subjective drive. This thesis introduces the historical development of speech synthesis and summarizes the general process of this technique. It is pointed out that prosody generation module is an important part in the process of speech synthesis. On the basis of further research, using eye activity rules when reading to control and drive prosody generation was introduced as a new human-computer interaction method to enrich the synthetic form. In this article, the present situation of speech synthesis technology is reviewed in detail. Based on the premise of eye gaze data extraction, using eye movement signal in real-time driving, a speech synthesis method which can express the real speech rhythm of the speaker is proposed. That is, when reader is watching corpora with its eyes in silent reading, capture the reading information such as the eye gaze duration per prosodic unit, and establish a hierarchical prosodic pattern of duration model to determine the duration parameters of synthesized speech. At last, after the analysis, the feasibility of the above method is verified.

  19. A new 3D reconstituted human corneal epithelium model as an alternative method for the eye irritation test.

    Science.gov (United States)

    Jung, Kyoung-Mi; Lee, Su-Hyon; Ryu, Yang-Hwan; Jang, Won-Hee; Jung, Haeng-Sun; Han, Ju-Hee; Seok, Seung-Hyeok; Park, Jae-Hak; Son, Youngsook; Park, Young-Ho; Lim, Kyung-Min

    2011-02-01

    Many efforts are being made to develop new alternative in vitro test methods for the eye irritation test. Here we report a new reconstructed human corneal epithelial model (MCTT HCE model) prepared from primary-cultured human limbal epithelial cells as a new alternative in vitro eye irritation test method. In histological and immunohistochemical observation, MCTT HCE model displayed a morphology and biomarker expressions similar to intact human cornea. Moreover, the barrier function was well preserved as measured by high transepithelial electrical resistance, effective time-50 for Triton X-100, and corneal thickness. To employ the model as a new alternative method for eye irritation test, protocol refinement was performed and optimum assay condition was determined including treatment time, treatment volume, post-incubation time and rinsing method. Using the refined protocol, 25 reference chemicals with known eye irritation potentials were tested. With the viability cut-off value at 50%, chemicals were classified to irritant or non-irritant. When compared with GHS classification, the MCTT HCE model showed the accuracy of 88%, sensitivity of 100% and specificity of 77%. These results suggest that the MCTT HCE model might be useful as a new alternative eye irritation test method. Copyright © 2010 Elsevier Ltd. All rights reserved.

  20. DESIGN AND APPLICATION OF SENSOR FOR RECORDING SOUNDS OVER HUMAN EYE AND NOSE

    NARCIS (Netherlands)

    JOURNEE, HL; VANBRUGGEN, AC; VANDERMEER, JJ; DEJONGE, AB; MOOIJ, JJA

    The recording of sounds over the oribt of the eye has been found to be useful in the detection of intracranial aneurysms. A hydrophone for auscultation over the eye has been developed and is tested under controlled conditions. The tests consist of measurement over the eyes in three healthy

  1. Reconstituted human corneal epithelium: a new alternative to the Draize eye test for the assessment of the eye irritation potential of chemicals and cosmetic products.

    Science.gov (United States)

    Doucet, O; Lanvin, M; Thillou, C; Linossier, C; Pupat, C; Merlin, B; Zastrow, L

    2006-06-01

    The aim of this study was to evaluate the interest of a new three-dimensional epithelial model cultivated from human corneal cells to replace animal testing in the assessment of eye tolerance. To this end, 65 formulated cosmetic products and 36 chemicals were tested by means of this in vitro model using a simplified toxicokinetic approach. The chemicals were selected from the ECETOC data bank and the EC/HO International validation study list. Very satisfactory results were obtained in terms of concordance with the Draize test data for the formulated cosmetic products. Moreover, the response of the corneal model appeared predictive of human ocular response clinically observed by ophthalmologists. The in vitro scores for the chemicals tested strongly correlated with their respective scores in vivo. For all the compounds tested, the response of the corneal model to irritants was similar regardless of their chemical structure, suggesting a good robustness of the prediction model proposed. We concluded that this new three-dimensional epithelial model, developed from human corneal cells, could be promising for the prediction of eye irritation induced by chemicals and complex formulated products, and that these two types of materials should be tested using a similar protocol. A simple shortening of the exposure period was required for the chemicals assumed to be more aggressively irritant to the epithelial tissues than the cosmetic formulae.

  2. CON4EI: SkinEthic™ Human Corneal Epithelium Eye Irritation Test (SkinEthic™ HCE EIT) for hazard identification and labelling of eye irritating chemicals.

    Science.gov (United States)

    Van Rompay, A R; Alépée, N; Nardelli, L; Hollanders, K; Leblanc, V; Drzewiecka, A; Gruszka, K; Guest, R; Kandarova, H; Willoughby, J A; Verstraelen, S; Adriaens, E

    2018-06-01

    Assessment of ocular irritancy is an international regulatory requirement and a necessary step in the safety evaluation of industrial and consumer products. Although a number of in vitro ocular irritation assays exist, none are capable of fully categorizing chemicals as a stand-alone assay. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was developed with the goal of assessing the reliability of eight in vitro/alternative test methods as well as establishing an optimal tiered-testing strategy. One of the in vitro assays selected was the validated SkinEthic™ Human Corneal Epithelium Eye Irritation Test method (SkinEthic™ HCE EIT). The SkinEthic™ HCE EIT has already demonstrated its capacity to correctly identify chemicals (both substances and mixtures) not requiring classification and labelling for eye irritation or serious eye damage (No Category). The goal of this study was to evaluate the performance of the SkinEthic™ HCE EIT test method in terms of the important in vivo drivers of classification. For the performance with respect to the drivers all in vivo Cat 1 and No Cat chemicals were 100% correctly identified. For Cat 2 chemicals the liquids and the solids had a sensitivity of 100% and 85.7%, respectively. For the SkinEthic™ HCE EIT test method, 100% concordance in predictions (No Cat versus No prediction can be made) between the two participating laboratories was obtained. The accuracy of the SkinEthic™ HCE EIT was 97.5% with 100% sensitivity and 96.9% specificity. The SkinEthic™ HCE EIT confirms its excellent results of the validation studies. Copyright © 2017. Published by Elsevier Ltd.

  3. Radiocarbon Dating of the Human Eye Lens Crystallines Reveal Proteins without Carbon Turnover throughout Life

    Science.gov (United States)

    Lynnerup, Niels; Kjeldsen, Henrik; Heegaard, Steffen; Jacobsen, Christina; Heinemeier, Jan

    2008-01-01

    Background Lens crystallines are special proteins in the eye lens. Because the epithelial basement membrane (lens capsule) completely encloses the lens, desquamation of aging cells is impossible, and due to the complete absence of blood vessels or transport of metabolites in this area, there is no subsequent remodelling of these fibers, nor removal of degraded lens fibers. Human tissue ultimately derives its 14C content from the atmospheric carbon dioxide. The 14C content of the lens proteins thus reflects the atmospheric content of 14C when the lens crystallines were formed. Precise radiocarbon dating is made possible by comparing the 14C content of the lens crystallines to the so-called bomb pulse, i.e. a plot of the atmospheric 14C content since the Second World War, when there was a significant increase due to nuclear-bomb testing. Since the change in concentration is significant even on a yearly basis this allows very accurate dating. Methodology/Principal Findings Our results allow us to conclude that the crystalline formation in the lens nucleus almost entirely takes place around the time of birth, with a very small, and decreasing, continuous formation throughout life. The close relationship may be further expressed as a mathematical model, which takes into account the timing of the crystalline formation. Conclusions/Significance Such a life-long permanence of human tissue has hitherto only been described for dental enamel. In confront to dental enamel it must be held in mind that the eye lens is a soft structure, subjected to almost continuous deformation, due to lens accommodation, yet its most important constituent, the lens crystalline, is never subject to turnover or remodelling once formed. The determination of the 14C content of various tissues may be used to assess turnover rates and degree of substitution (for example for brain cell DNA). Potential targets may be nervous tissues in terms of senile or pre-senile degradation, as well as other highly

  4. Radiocarbon dating of the human eye lens crystallines reveal proteins without carbon turnover throughout life.

    Directory of Open Access Journals (Sweden)

    Niels Lynnerup

    Full Text Available BACKGROUND: Lens crystallines are special proteins in the eye lens. Because the epithelial basement membrane (lens capsule completely encloses the lens, desquamation of aging cells is impossible, and due to the complete absence of blood vessels or transport of metabolites in this area, there is no subsequent remodelling of these fibers, nor removal of degraded lens fibers. Human tissue ultimately derives its (14C content from the atmospheric carbon dioxide. The (14C content of the lens proteins thus reflects the atmospheric content of (14C when the lens crystallines were formed. Precise radiocarbon dating is made possible by comparing the (14C content of the lens crystallines to the so-called bomb pulse, i.e. a plot of the atmospheric (14C content since the Second World War, when there was a significant increase due to nuclear-bomb testing. Since the change in concentration is significant even on a yearly basis this allows very accurate dating. METHODOLOGY/PRINCIPAL FINDINGS: Our results allow us to conclude that the crystalline formation in the lens nucleus almost entirely takes place around the time of birth, with a very small, and decreasing, continuous formation throughout life. The close relationship may be further expressed as a mathematical model, which takes into account the timing of the crystalline formation. CONCLUSIONS/SIGNIFICANCE: Such a life-long permanence of human tissue has hitherto only been described for dental enamel. In confront to dental enamel it must be held in mind that the eye lens is a soft structure, subjected to almost continuous deformation, due to lens accommodation, yet its most important constituent, the lens crystalline, is never subject to turnover or remodelling once formed. The determination of the (14C content of various tissues may be used to assess turnover rates and degree of substitution (for example for brain cell DNA. Potential targets may be nervous tissues in terms of senile or pre

  5. Computing the influences of different Intraocular Pressures on the human eye components using computational fluid-structure interaction model.

    Science.gov (United States)

    Karimi, Alireza; Razaghi, Reza; Navidbakhsh, Mahdi; Sera, Toshihiro; Kudo, Susumu

    2017-01-01

    Intraocular Pressure (IOP) is defined as the pressure of aqueous in the eye. It has been reported that the normal range of IOP should be within the 10-20 mmHg with an average of 15.50 mmHg among the ophthalmologists. Keratoconus is an anti-inflammatory eye disorder that debilitated cornea unable to reserve the normal structure contrary to the IOP in the eye. Consequently, the cornea would bulge outward and invoke a conical shape following by distorted vision. In addition, it is known that any alterations in the structure and composition of the lens and cornea would exceed a change of the eye ball as well as the mechanical and optical properties of the eye. Understanding the precise alteration of the eye components' stresses and deformations due to different IOPs could help elucidate etiology and pathogenesis to develop treatments not only for keratoconus but also for other diseases of the eye. In this study, at three different IOPs, including 10, 20, and 30 mmHg the stresses and deformations of the human eye components were quantified using a Three-Dimensional (3D) computational Fluid-Structure Interaction (FSI) model of the human eye. The results revealed the highest amount of von Mises stress in the bulged region of the cornea with 245 kPa at the IOP of 30 mmHg. The lens was also showed the von Mises stress of 19.38 kPa at the IOPs of 30 mmHg. In addition, by increasing the IOP from 10 to 30 mmHg, the radius of curvature in the cornea and lens was increased accordingly. In contrast, the sclera indicated its highest stress at the IOP of 10 mmHg due to over pressure phenomenon. The variation of IOP illustrated a little influence in the amount of stress as well as the resultant displacement of the optic nerve. These results can be used for understanding the amount of stresses and deformations in the human eye components due to different IOPs as well as for clarifying significant role of IOP on the radius of curvature of the cornea and the lens.

  6. Towards free 3D end-point control for robotic-assisted human reaching using binocular eye tracking.

    Science.gov (United States)

    Maimon-Dror, Roni O; Fernandez-Quesada, Jorge; Zito, Giuseppe A; Konnaris, Charalambos; Dziemian, Sabine; Faisal, A Aldo

    2017-07-01

    Eye-movements are the only directly observable behavioural signals that are highly correlated with actions at the task level, and proactive of body movements and thus reflect action intentions. Moreover, eye movements are preserved in many movement disorders leading to paralysis (or amputees) from stroke, spinal cord injury, Parkinson's disease, multiple sclerosis, and muscular dystrophy among others. Despite this benefit, eye tracking is not widely used as control interface for robotic interfaces in movement impaired patients due to poor human-robot interfaces. We demonstrate here how combining 3D gaze tracking using our GT3D binocular eye tracker with custom designed 3D head tracking system and calibration method enables continuous 3D end-point control of a robotic arm support system. The users can move their own hand to any location of the workspace by simple looking at the target and winking once. This purely eye tracking based system enables the end-user to retain free head movement and yet achieves high spatial end point accuracy in the order of 6 cm RMSE error in each dimension and standard deviation of 4 cm. 3D calibration is achieved by moving the robot along a 3 dimensional space filling Peano curve while the user is tracking it with their eyes. This results in a fully automated calibration procedure that yields several thousand calibration points versus standard approaches using a dozen points, resulting in beyond state-of-the-art 3D accuracy and precision.

  7. Verification of the lack of correlation between age and longitudinal chromatic aberrations of the human eye from the visible to the infrared

    Science.gov (United States)

    Nakajima, Masashi; Hiraoka, Takahiro; Hirohara, Yoko; Oshika, Tetsuro; Mihashi, Toshifumi

    2015-01-01

    Several researchers studied the longitudinal chromatic aberration (LCA) of the human eye and observed that it does not change due to age. We measured the LCA of 45 subjects’ normal right eyes at three distinct wavelengths (561, 690, and 840 nm) using a Hartmann–Shack wavefront aberrometer (HSWA) while consecutively switching between three light sources for wavefront sensing. We confirmed that the LCA of the human eye does not change due to age between 22 and 57 years. PMID:26203391

  8. Dry Eye

    Science.gov (United States)

    ... Eye » Facts About Dry Eye Listen Facts About Dry Eye Fact Sheet Blurb The National Eye Institute (NEI) ... and their families search for general information about dry eye. An eye care professional who has examined the ...

  9. Telomere Length and Mortality

    DEFF Research Database (Denmark)

    Kimura, Masayuki; Hjelmborg, Jacob V B; Gardner, Jeffrey P

    2008-01-01

    Leukocyte telomere length, representing the mean length of all telomeres in leukocytes, is ostensibly a bioindicator of human aging. The authors hypothesized that shorter telomeres might forecast imminent mortality in elderly people better than leukocyte telomere length. They performed mortality...

  10. An Interactive Method for Teaching Anatomy of the Human Eye for Medical Students in Ophthalmology Clinical Rotations

    Science.gov (United States)

    Kivell, Tracy L.; Doyle, Sara K.; Madden, Richard H.; Mitchell, Terry L.; Sims, Ershela L.

    2009-01-01

    Much research has shown the benefits of additional anatomical learning and dissection beyond the first year of medical school human gross anatomy, all the way through postgraduate medical training. We have developed an interactive method for teaching eye and orbit anatomy to medical students in their ophthalmology rotation at Duke University…

  11. Simultaneous recordings of human microsaccades and drifts with a contemporary video eye tracker and the search coil technique.

    Directory of Open Access Journals (Sweden)

    Michael B McCamy

    Full Text Available Human eyes move continuously, even during visual fixation. These "fixational eye movements" (FEMs include microsaccades, intersaccadic drift and oculomotor tremor. Research in human FEMs has grown considerably in the last decade, facilitated by the manufacture of noninvasive, high-resolution/speed video-oculography eye trackers. Due to the small magnitude of FEMs, obtaining reliable data can be challenging, however, and depends critically on the sensitivity and precision of the eye tracking system. Yet, no study has conducted an in-depth comparison of human FEM recordings obtained with the search coil (considered the gold standard for measuring microsaccades and drift and with contemporary, state-of-the art video trackers. Here we measured human microsaccades and drift simultaneously with the search coil and a popular state-of-the-art video tracker. We found that 95% of microsaccades detected with the search coil were also detected with the video tracker, and 95% of microsaccades detected with video tracking were also detected with the search coil, indicating substantial agreement between the two systems. Peak/mean velocities and main sequence slopes of microsaccades detected with video tracking were significantly higher than those of the same microsaccades detected with the search coil, however. Ocular drift was significantly correlated between the two systems, but drift speeds were higher with video tracking than with the search coil. Overall, our combined results suggest that contemporary video tracking now approaches the search coil for measuring FEMs.

  12. Do climate variables and human density affect Achatina fulica (Bowditch) (Gastropoda: Pulmonata) shell length, total weight and condition factor?

    Science.gov (United States)

    Albuquerque, F S; Peso-Aguiar, M C; Assunção-Albuquerque, M J T; Gálvez, L

    2009-08-01

    The length-weight relationship and condition factor have been broadly investigated in snails to obtain the index of physical condition of populations and evaluate habitat quality. Herein, our goal was to describe the best predictors that explain Achatina fulica biometrical parameters and well being in a recently introduced population. From November 2001 to November 2002, monthly snail samples were collected in Lauro de Freitas City, Bahia, Brazil. Shell length and total weight were measured in the laboratory and the potential curve and condition factor were calculated. Five environmental variables were considered: temperature range, mean temperature, humidity, precipitation and human density. Multiple regressions were used to generate models including multiple predictors, via model selection approach, and then ranked with AIC criteria. Partial regressions were used to obtain the separated coefficients of determination of climate and human density models. A total of 1.460 individuals were collected, presenting a shell length range between 4.8 to 102.5 mm (mean: 42.18 mm). The relationship between total length and total weight revealed that Achatina fulica presented a negative allometric growth. Simple regression indicated that humidity has a significant influence on A. fulica total length and weight. Temperature range was the main variable that influenced the condition factor. Multiple regressions showed that climatic and human variables explain a small proportion of the variance in shell length and total weight, but may explain up to 55.7% of the condition factor variance. Consequently, we believe that the well being and biometric parameters of A. fulica can be influenced by climatic and human density factors.

  13. Do climate variables and human density affect Achatina fulica (Bowditch (Gastropoda: Pulmonata shell length, total weight and condition factor?

    Directory of Open Access Journals (Sweden)

    FS. Albuquerque

    Full Text Available The length-weight relationship and condition factor have been broadly investigated in snails to obtain the index of physical condition of populations and evaluate habitat quality. Herein, our goal was to describe the best predictors that explain Achatina fulica biometrical parameters and well being in a recently introduced population. From November 2001 to November 2002, monthly snail samples were collected in Lauro de Freitas City, Bahia, Brazil. Shell length and total weight were measured in the laboratory and the potential curve and condition factor were calculated. Five environmental variables were considered: temperature range, mean temperature, humidity, precipitation and human density. Multiple regressions were used to generate models including multiple predictors, via model selection approach, and then ranked with AIC criteria. Partial regressions were used to obtain the separated coefficients of determination of climate and human density models. A total of 1.460 individuals were collected, presenting a shell length range between 4.8 to 102.5 mm (mean: 42.18 mm. The relationship between total length and total weight revealed that Achatina fulica presented a negative allometric growth. Simple regression indicated that humidity has a significant influence on A. fulica total length and weight. Temperature range was the main variable that influenced the condition factor. Multiple regressions showed that climatic and human variables explain a small proportion of the variance in shell length and total weight, but may explain up to 55.7% of the condition factor variance. Consequently, we believe that the well being and biometric parameters of A. fulica can be influenced by climatic and human density factors.

  14. Influence of hydration and experimental length scale on themechanical response of human skin in vivo, using optical coherence tomography

    NARCIS (Netherlands)

    Hendriks, F.M.; Brokken, D.; Oomens, C.W.J.; Baaijens, F.P.T.

    2004-01-01

    Human skin is a complex tissue consisting of different layers. To gain better insight into the mechanical behaviour of different skin layers, the mechanical response was studied with experiments of various length scales. Also, the influence of (superficial) hydration on the mechanical response is

  15. Optical imaging of the chorioretinal vasculature in the living human eye.

    Science.gov (United States)

    Kim, Dae Yu; Fingler, Jeff; Zawadzki, Robert J; Park, Susanna S; Morse, Lawrence S; Schwartz, Daniel M; Fraser, Scott E; Werner, John S

    2013-08-27

    Detailed visualization of microvascular changes in the human retina is clinically limited by the capabilities of angiography imaging, a 2D fundus photograph that requires an intravenous injection of fluorescent dye. Whereas current angiography methods enable visualization of some retinal capillary detail, they do not adequately reveal the choriocapillaris or other microvascular features beneath the retina. We have developed a noninvasive microvascular imaging technique called phase-variance optical coherence tomography (pvOCT), which identifies vasculature three dimensionally through analysis of data acquired with OCT systems. The pvOCT imaging method is not only capable of generating capillary perfusion maps for the retina, but it can also use the 3D capabilities to segment the data in depth to isolate vasculature in different layers of the retina and choroid. This paper demonstrates some of the capabilities of pvOCT imaging of the anterior layers of choroidal vasculature of a healthy normal eye as well as of eyes with geographic atrophy (GA) secondary to age-related macular degeneration. The pvOCT data presented permit digital segmentation to produce 2D depth-resolved images of the retinal vasculature, the choriocapillaris, and the vessels in Sattler's and Haller's layers. Comparisons are presented between en face projections of pvOCT data within the superficial choroid and clinical angiography images for regions of GA. Abnormalities and vascular dropout observed within the choriocapillaris for pvOCT are compared with regional GA progression. The capability of pvOCT imaging of the microvasculature of the choriocapillaris and the anterior choroidal vasculature has the potential to become a unique tool to evaluate therapies and understand the underlying mechanisms of age-related macular degeneration progression.

  16. Oxygen Tension in the Aqueous Humor of Human Eyes under Different Oxygenation Conditions

    Directory of Open Access Journals (Sweden)

    Farideh Sharifipour

    2013-01-01

    Full Text Available Purpose: To measure oxygen tension in the aqueous humor of human eyes under different oxygenation conditions. Methods: This prospective comparative interventional case series consisted of two parts. In the first part, 120 consecutive patients scheduled for cataract surgery were randomized into group I (control group in which surgery was performed under local anesthesia inhaling 21% oxygen; group II in whom general anesthesia using 50% oxygen was employed; and group III receiving general anesthesia with 100% oxygen. After aspirating 0.2 ml aqueous humor under sterile conditions, the aqueous sample and a simultaneously drawn arterial blood sample were immediately analyzed using a blood gas analyzer. In part II the same procedures were performed in 10 patients after fitting a contact lens and patching the eye for 20 minutes (group IV and in 10 patients after transcorneal delivery of oxygen at a flow rate of 5 L/min (group V. Results: Mean aqueous PO2 in groups I, II and III was 112.3±6.2, 141.1±20.4, and 170.1±27 mmHg, respectively (P values <0.001 and mean arterial PO2 was 85.7±7.9, 184.6±46, and 379.1±75.9 mmHg, respectively (P values <0.001. Aqueous PO2 was 77.2±9.2 mmHg in group IV and 152.3±10.9 mmHg in group V (P values <0.001. There was a significant correlation between aqueous and blood PO2 (r=0.537, P<0.001. The contribution of atmospheric oxygen to aqueous PO2 was 23.7%. Conclusion: Aqueous oxygen tension is mostly dependent on the systemic circulation and in part on the atmosphere. Increasing inspiratory oxygen and transcorneal oxygen delivery both increase aqueous PO2 levels.

  17. A novel device for head gesture measurement system in combination with eye-controlled human machine interface

    Science.gov (United States)

    Lin, Chern-Sheng; Ho, Chien-Wa; Chang, Kai-Chieh; Hung, San-Shan; Shei, Hung-Jung; Yeh, Mau-Shiun

    2006-06-01

    This study describes the design and combination of an eye-controlled and a head-controlled human-machine interface system. This system is a highly effective human-machine interface, detecting head movement by changing positions and numbers of light sources on the head. When the users utilize the head-mounted display to browse a computer screen, the system will catch the images of the user's eyes with CCD cameras, which can also measure the angle and position of the light sources. In the eye-tracking system, the program in the computer will locate each center point of the pupils in the images, and record the information on moving traces and pupil diameters. In the head gesture measurement system, the user wears a double-source eyeglass frame, so the system catches images of the user's head by using a CCD camera in front of the user. The computer program will locate the center point of the head, transferring it to the screen coordinates, and then the user can control the cursor by head motions. We combine the eye-controlled and head-controlled human-machine interface system for the virtual reality applications.

  18. Lipid-protein interactions in plasma membranes of fiber cells isolated from the human eye lens.

    Science.gov (United States)

    Raguz, Marija; Mainali, Laxman; O'Brien, William J; Subczynski, Witold K

    2014-03-01

    The protein content in human lens membranes is extremely high, increases with age, and is higher in the nucleus as compared with the cortex, which should strongly affect the organization and properties of the lipid bilayer portion of intact membranes. To assess these effects, the intact cortical and nuclear fiber cell plasma membranes isolated from human lenses from 41- to 60-year-old donors were studied using electron paramagnetic resonance spin-labeling methods. Results were compared with those obtained for lens lipid membranes prepared from total lipid extracts from human eyes of the same age group [Mainali, L., Raguz, M., O'Brien, W. J., and Subczynski, W. K. (2013) Biochim. Biophys. Acta]. Differences were considered to be mainly due to the effect of membrane proteins. The lipid-bilayer portions of intact membranes were significantly less fluid than lipid bilayers of lens lipid membranes, prepared without proteins. The intact membranes were found to contain three distinct lipid environments termed the bulk lipid domain, boundary lipid domain, and trapped lipid domain. However, the cholesterol bilayer domain, which was detected in cortical and nuclear lens lipid membranes, was not detected in intact membranes. The relative amounts of bulk and trapped lipids were evaluated. The amount of lipids in domains uniquely formed due to the presence of membrane proteins was greater in nuclear membranes than in cortical membranes. Thus, it is evident that the rigidity of nuclear membranes is greater than that of cortical membranes. Also the permeability coefficients for oxygen measured in domains of nuclear membranes were significantly lower than appropriate coefficients measured in cortical membranes. Relationships between the organization of lipids into lipid domains in fiber cells plasma membranes and the organization of membrane proteins are discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Estimation of the in vitro eye irritating and inflammatory potential of lipopolysaccharide (LPS) and dust by using reconstituted human corneal epithelium tissue cultures

    DEFF Research Database (Denmark)

    Cao, Yi; Arenholt-Bindslev, Dorthe; Kjærgaard, Søren K

    2015-01-01

    CONTEXT: Eye irritation is a common complaint in indoor environment, but the causes have still not been identified among the multiple exposures in house environments. To identify the potential environmental factors responsible for eye irritation and study the possible mechanisms, an in vitro model...... AND CONCLUSION: LPS and dust showed in vitro eye irritating and inflammatory potential, and cytokines/chemokines like IL-1β and IL-8 may be involved in the mechanisms of eye irritation. The HCE tissue culture may be used as an in vitro model to study environmental exposure induced eye irritation and inflammation....... for eye irritation is suggested. MATERIALS AND METHODS: In this study, reconstituted human corneal epithelium (HCE) tissue cultures were used to study the eye irritating and inflammatory potential of lipopolysaccharide (LPS) and dust. HCE tissue cultures were exposed to a range of concentrations of LPS...

  20. Microstructure, length, and connection of limbic tracts in normal human brain development

    Directory of Open Access Journals (Sweden)

    Qiaowen eYu

    2014-08-01

    Full Text Available The cingulum and fornix play an important role in memory, attention, spatial orientation and feeling functions. Both microstructure and length of these limbic tracts can be affected by mental disorders such as Alzheimer’s disease, depression, autism, anxiety, and schizophrenia. To date, there has been little systematic characterization of their microstructure, length and functional connectivity in normally developing brains. In this study, diffusion tensor imaging (DTI and resting state functional MRI (rs-fMRI data from 65 normally developing right-handed subjects from birth to young adulthood was acquired. After cingulate gyrus part of the cingulum (cgc, hippocampal part of the cingulum (cgh and fornix (fx were traced with DTI tractography, absolute and normalized tract lengths and DTI-derived metrics including fractional anisotropy, mean, axial and radial diffusivity were measured for traced limbic tracts. Free water elimination (FWE algorithm was adopted to improve accuracy of the measurements of DTI-derived metrics. The role of these limbic tracts in the functional network at birth and adulthood was explored. We found a logarithmic age-dependent trajectory for FWE-corrected DTI metric changes with fast increase of microstructural integrity from birth to 2-year-old followed by a slow increase to 25-year-old. Normalized tract length of cgc increases with age, while no significant relationship with age was found for normalized tract lengths of cgh and fx. Stronger microstructural integrity on the left side compared to that of right side was found. With integrated DTI and rs-fMRI, the key connectional role of cgc and cgh in the default mode network (DMN was confirmed as early as birth. Systematic characterization of length and DTI metrics after FWE correction of limbic tracts offers insight into their morphological and microstructural developmental trajectories. These trajectories may serve as a normal reference for pediatric patients with

  1. The effect of regular strength training on telomere length in human skeletal muscle

    DEFF Research Database (Denmark)

    Kadi, F.; Ponsot, Elodie; Piehl-Aulin, Karin

    2008-01-01

    PURPOSE: The length of DNA telomeres is an important parameter of the proliferative potential of tissues. A recent study has reported abnormally short telomeres in skeletal muscle of athletes with exercise-associated fatigue. This important report raises the question of whether long-term practice...... of sports might have deleterious effects on muscle telomeres. Therefore, we aimed to compare telomere length of a group of power lifters (PL; N = 7) who trained for 8 +/- 3 yr against that of a group of healthy, active subjects (C; N = 7) with no history of strength training. METHODS: Muscle biopsies were...

  2. Xenopus pax6 mutants affect eye development and other organ systems, and have phenotypic similarities to human aniridia patients.

    Science.gov (United States)

    Nakayama, Takuya; Fisher, Marilyn; Nakajima, Keisuke; Odeleye, Akinleye O; Zimmerman, Keith B; Fish, Margaret B; Yaoita, Yoshio; Chojnowski, Jena L; Lauderdale, James D; Netland, Peter A; Grainger, Robert M

    2015-12-15

    Mutations in the Pax6 gene cause ocular defects in both vertebrate and invertebrate animal species, and the disease aniridia in humans. Despite extensive experimentation on this gene in multiple species, including humans, we still do not understand the earliest effects on development mediated by this gene. This prompted us to develop pax6 mutant lines in Xenopus tropicalis taking advantage of the utility of the Xenopus system for examining early development and in addition to establish a model for studying the human disease aniridia in an accessible lower vertebrate. We have generated mutants in pax6 by using Transcription Activator-Like Effector Nuclease (TALEN) constructs for gene editing in X. tropicalis. Embryos with putative null mutations show severe eye abnormalities and changes in brain development, as assessed by changes in morphology and gene expression. One gene that we found is downregulated very early in development in these pax6 mutants is myc, a gene involved in pluripotency and progenitor cell maintenance and likely a mediator of some key pax6 functions in the embryo. Changes in gene expression in the developing brain and pancreas reflect other important functions of pax6 during development. In mutations with partial loss of pax6 function eye development is initially relatively normal but froglets show an underdeveloped iris, similar to the classic phenotype (aniridia) seen in human patients with PAX6 mutations. Other eye abnormalities observed in these froglets, including cataracts and corneal defects, are also common in human aniridia. The frog model thus allows us to examine the earliest deficits in eye formation as a result of pax6 lesions, and provides a useful model for understanding the developmental basis for the aniridia phenotype seen in humans. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Influence of Misalignment on High-Order Aberration Correction for Normal Human Eyes

    Science.gov (United States)

    Zhao, Hao-Xin; Xu, Bing; Xue, Li-Xia; Dai, Yun; Liu, Qian; Rao, Xue-Jun

    2008-04-01

    Although a compensation device can correct aberrations of human eyes, the effect will be degraded by its misalignment, especially for high-order aberration correction. We calculate the positioning tolerance of correction device for high-order aberrations, and within what degree the correcting effect is better than low-order aberration (defocus and astigmatism) correction. With fixed certain misalignment within the positioning tolerance, we calculate the residual wavefront rms aberration of the first-6 to first-35 terms along with the 3rd-5th terms of aberrations corrected, and the combined first-13 terms of aberrations are also studied under the same quantity of misalignment. However, the correction effect of high-order aberrations does not meliorate along with the increase of the high-order terms under some misalignment, moreover, some simple combined terms correction can achieve similar result as complex combinations. These results suggest that it is unnecessary to correct too much the terms of high-order aberrations which are difficult to accomplish in practice, and gives confidence to correct high-order aberrations out of the laboratory.

  4. Ab interno trabeculectomy: ultrastructural evidence and early tissue response in a human eye.

    Science.gov (United States)

    Ferrari, Ettore; Ortolani, Fulvia; Petrelli, Lucia; Contin, Magali; Pognuz, Derri Roman; Marchini, Maurizio; Bandello, Francesco

    2007-10-01

    To report the results of ultrastructural analysis of the postoperative effects of ab interno trabeculectomy in a human eye. Department of Ophthalmology, Palmanova Hospital, Palmanova, Udine, Italy. A 60-year-old woman with cataract and glaucoma had enucleation for a choroidal melanoma 10 days after ab interno trabeculectomy combined with phacoemulsification. A second ab interno trabeculectomy was performed after enucleation to evaluate the outcomes of the previous trabeculectomy. Light and transmission electron microscopy analyses were performed on samples excised from areas (1) not subjected to a procedure (control samples), (2) that had ab interno trabeculectomy before enucleation, and (3) that had ab interno trabeculectomy immediately after enucleation. Control samples showed normal trabecular features. Semithin sections of all ab interno trabeculectomy samples showed full-thickness removal of trabeculum segments, with Schlemm's canal lumen opening into the anterior chamber and apparent preservation of the adjacent structures. On ultrathin sections of samples that had ab interno trabeculectomy before enucleation, the endothelium lining the outer wall of Schlemm's canal and other angle components showed intact ultrastructural features. In trabecular beams that were not removed, the extracellular matrix appeared to have maintained its fine texture and was free of activated fibroblasts or leucocyte infiltrates. Observations confirm that ab interno trabeculectomy causes direct communication between Schlemm's canal lumen and the anterior chamber in vivo and immediately after enucleation during the early postoperative period. The absence of an evident inflammatory reaction in the examined case should be considered with caution because of possible tumor-induced immune suppression.

  5. Method to investigate temporal dynamics of ganglion and other retinal cells in the living human eye

    Science.gov (United States)

    Kurokawa, Kazuhiro; Liu, Zhuolin; Crowell, James; Zhang, Furu; Miller, Donald T.

    2018-02-01

    The inner retina is critical for visual processing, but much remains unknown about its neural circuitry and vulnerability to disease. A major bottleneck has been our inability to observe the structure and function of the cells composing these retinal layers in the living human eye. Here, we present a noninvasive method to observe both structural and functional information. Adaptive optics optical coherence tomography (AO-OCT) is used to resolve the inner retinal cells in all three dimensions and novel post processing algorithms are applied to extract structure and physiology down to the cellular level. AO-OCT captured the 3D mosaic of individual ganglion cell somas, retinal nerve fiber bundles of micron caliber, and microglial cells, all in exquisite detail. Time correlation analysis of the AO-OCT videos revealed notable temporal differences between the principal layers of the inner retina. The GC layer was more dynamic than the nerve fiber and inner plexiform layers. At the cellular level, we applied a customized correlation method to individual GCL somas, and found a mean time constant of activity of 0.57 s and spread of +/-0.1 s suggesting a range of physiological dynamics even in the same cell type. Extending our method to slower dynamics (from minutes to one year), time-lapse imaging and temporal speckle contrast revealed appendage and soma motion of resting microglial cells at the retinal surface.

  6. Influence of Misalignment on High-Order Aberration Correction for Normal Human Eyes

    International Nuclear Information System (INIS)

    Hao-Xin, Zhao; Bing, Xu; Li-Xia, Xue; Yun, Dai; Qian, Liu; Xue-Jun, Rao

    2008-01-01

    Although a compensation device can correct aberrations of human eyes, the effect will be degraded by its misalignment, especially for high-order aberration correction. We calculate the positioning tolerance of correction device for high-order aberrations, and within what degree the correcting effect is better than low-order aberration (defocus and astigmatism) correction. With fixed certain misalignment within the positioning tolerance, we calculate the residual wavefront rms aberration of the first-6 to first-35 terms along with the 3rd-5th terms of aberrations corrected, and the combined first-13 terms of aberrations are also studied under the same quantity of misalignment. However, the correction effect of high-order aberrations does not meliorate along with the increase of the high-order terms under some misalignment, moreover, some simple combined terms correction can achieve similar result as complex combinations. These results suggest that it is unnecessary to correct too much the terms of high-order aberrations which are difficult to accomplish in practice, and gives confidence to correct high-order aberrations out of the laboratory

  7. The effects of radiant cooling versus convective cooling on human eye tear film stability and blinking rate

    DEFF Research Database (Denmark)

    Nygaard, Linette; Uth, Simon C.; Bolashikov, Zhecho Dimitrov

    2014-01-01

    The effect of indoor temperature, radiant and convective cooling on tear film stability and eye blink frequency was examined. 24 human subjects were exposed to the non-uniform environment generated by localised chilled beam and a chilled ceiling combined with overhead mixing ventilation. The subj......The effect of indoor temperature, radiant and convective cooling on tear film stability and eye blink frequency was examined. 24 human subjects were exposed to the non-uniform environment generated by localised chilled beam and a chilled ceiling combined with overhead mixing ventilation....... The subjects participated in four two-hour experiments. The room air temperature was kept at 26 °C or 28 °C. Tear film samples were collected after 30 min of acclimatisation and at the end of the exposures. Eye blinking frequency was analysed for the first and last 15 min of each exposure. The tear film...... stability decreased as the temperature increased. The highest number of subjects with unchanged or improved tear film quality was observed with the localised chilled beam at 26 °C. A trend was found between subjects who reported eye irritation and had a bad tear film quality....

  8. Apnea-induced rapid eye movement sleep disruption impairs human spatial navigational memory.

    Science.gov (United States)

    Varga, Andrew W; Kishi, Akifumi; Mantua, Janna; Lim, Jason; Koushyk, Viachaslau; Leibert, David P; Osorio, Ricardo S; Rapoport, David M; Ayappa, Indu

    2014-10-29

    Hippocampal electrophysiology and behavioral evidence support a role for sleep in spatial navigational memory, but the role of particular sleep stages is less clear. Although rodent models suggest the importance of rapid eye movement (REM) sleep in spatial navigational memory, a similar role for REM sleep has never been examined in humans. We recruited subjects with severe obstructive sleep apnea (OSA) who were well treated and adherent with continuous positive airway pressure (CPAP). Restricting CPAP withdrawal to REM through real-time monitoring of the polysomnogram provides a novel way of addressing the role of REM sleep in spatial navigational memory with a physiologically relevant stimulus. Individuals spent two different nights in the laboratory, during which subjects performed timed trials before and after sleep on one of two unique 3D spatial mazes. One night of sleep was normally consolidated with use of therapeutic CPAP throughout, whereas on the other night, CPAP was reduced only in REM sleep, allowing REM OSA to recur. REM disruption via this method caused REM sleep reduction and significantly fragmented any remaining REM sleep without affecting total sleep time, sleep efficiency, or slow-wave sleep. We observed improvements in maze performance after a night of normal sleep that were significantly attenuated after a night of REM disruption without changes in psychomotor vigilance. Furthermore, the improvement in maze completion time significantly positively correlated with the mean REM run duration across both sleep conditions. In conclusion, we demonstrate a novel role for REM sleep in human memory formation and highlight a significant cognitive consequence of OSA. Copyright © 2014 the authors 0270-6474/14/3414571-07$15.00/0.

  9. MicroRNA Profiling in Aqueous Humor of Individual Human Eyes by Next-Generation Sequencing.

    Science.gov (United States)

    Wecker, Thomas; Hoffmeier, Klaus; Plötner, Anne; Grüning, Björn Andreas; Horres, Ralf; Backofen, Rolf; Reinhard, Thomas; Schlunck, Günther

    2016-04-01

    Extracellular microRNAs (miRNAs) in aqueous humor were suggested to have a role in transcellular signaling and may serve as disease biomarkers. The authors adopted next-generation sequencing (NGS) techniques to further characterize the miRNA profile in single samples of 60 to 80 μL human aqueous humor. Samples were obtained at the outset of cataract surgery in nine independent, otherwise healthy eyes. Four samples were used to extract RNA and generate sequencing libraries, followed by an adapter-driven amplification step, electrophoretic size selection, sequencing, and data analysis. Five samples were used for quantitative PCR (qPCR) validation of NGS results. Published NGS data on circulating miRNAs in blood were analyzed in comparison. One hundred fifty-eight miRNAs were consistently detected by NGS in all four samples; an additional 59 miRNAs were present in at least three samples. The aqueous humor miRNA profile shows some overlap with published NGS-derived inventories of circulating miRNAs in blood plasma with high prevalence of human miR-451a, -21, and -16. In contrast to blood, miR-184, -4448, -30a, -29a, -29c, -19a, -30d, -205, -24, -22, and -3074 were detected among the 20 most prevalent miRNAs in aqueous humor. Relative expression patterns of miR-451a, -202, and -144 suggested by NGS were confirmed by qPCR. Our data illustrate the feasibility of miRNA analysis by NGS in small individual aqueous humor samples. Intraocular cells as well as blood plasma contribute to the extracellular aqueous humor miRNome. The data suggest possible roles of miRNA in intraocular cell adhesion and signaling by TGF-β and Wnt, which are important in intraocular pressure regulation and glaucoma.

  10. TERRA Expression Levels Do Not Correlate With Telomere Length and Radiation Sensitivity in Human Cancer Cell Lines

    Directory of Open Access Journals (Sweden)

    Alexandra eSmirnova

    2013-05-01

    Full Text Available Mammalian telomeres are transcribed into long non-coding telomeric RNA molecules (TERRA that seem to play a role in the maintenance of telomere stability. In human cells, CpG island promoters drive TERRA transcription and are regulated by methylation. It was suggested that the amount of TERRA may be related to telomere length. To test this hypothesis we measured telomere length and TERRA levels in single clones isolated from five human cell lines: HeLa (cervical carcinoma, BRC-230 (breast cancer, AKG and GK2 (gastric cancers and GM847 (SV40 immortalized skin fibroblasts. We observed great clonal heterogeneity both in TRF (Terminal Restriction Fragment length and in TERRA levels. However, these two parameters did not correlate with each other. Moreover, cell survival to γ-rays did not show a significant variation among the clones, suggesting that, in this cellular system, the intra-population variability in telomere length and TERRA levels does not influence sensitivity to ionizing radiation. This conclusion was supported by the observation that in a cell line in which telomeres were greatly elongated by the ectopic expression of telomerase, TERRA expression levels and radiation sensitivity were similar to the parental HeLa cell line.

  11. Characterization of the vitreous body of the human eye using a cyanine dye as a spectral and fluorescent probe

    Science.gov (United States)

    Panova, Ina G.; Tatikolov, Alexander S.

    2009-02-01

    We used one of cyanine dyes as a spectral and fluorescent probe in the study of the composition of the extracellular matrix of the human eye (its vitreous body). Owing to the unique ability of the dye to bind to collagens and human serum albumin, we revealed the simultaneous presence of both types of biomacromolecules in the vitreous body. The formation of the dye complex with human serum albumin leads to appearance of a long-wavelength absorption band (~612 nm) and a steep rise of fluorescence, whereas in the presence of collagens the dye forms J-aggregates with a longer-wavelength absorption band (640-660 nm) and moderate fluorescence. In this work we studied the composition of the human fetus vitreous body and its dynamics from 9 to 31 gestation weeks. On the basis of the data obtained by this method, we may assume that albumin, being a carrier protein, probably provides the vitreous body and surrounding tissues with necessary growth factors, hormones, lipids, vitamins, and some other biomolecules. The data show that the dye is promising not only for study of albumin functions in eye development, but also for characterization of some eye diseases and for analysis of other extracellular media.

  12. Eye safety report 1 (dual wavelength). Human risk analysis simulator for space lidars

    International Nuclear Information System (INIS)

    Schulmeister, K.; Mellerio, J.; Sonneck, G.

    2001-09-01

    This report contains the results of a risk study for a satellite based lidar mission that uses two different laser wavelengths to measure atmospheric properties. A lidar can be considered as a laser radar and is an acronym for light detection and ranging. The lidar measures properties of the atmosphere by analysis of laser radiation that is directed back to the lidar. As only part of the laser radiation is scattered ir absorbed by the atmosphere, the remaining laser radiation emitted from the spacecraft is incident on the earth's surface, where it might lead to injuries, especially to the eye, if biological thresholds are exceeded. For the analysed mission there is no hazard to the skin, only a potential one to the eye. Because the footprint of the satellite's laser beam on the surface of the earth is so small and it moves so fast, the chance of the naked eye being exposed to the laser is small. Because of the magnification provided by an optical instrument, and the concomitant reduction in the field of view, the probability of exposure of an eye that is using such an instrument decreases with increasing optical power. However, because an increased optical power implies increased diameter of the light gathering optics, the laser energy delivered to an eye increases with instrument size so that if exposure did occur, the probability of delivering energy to the eye that exceeds the threshold for damage increases. There are thus two conflicting processes at work for viewing with optical instruments: an increase in diameter increases the energy delivered but reduces the probability of lidar beam interception. Energy delivered to the eye is such that damage thresholds will not be exceeded for naked eye viewing or for the use of small optical instruments. Exposure via telescopes with diameter larger than 12 cm could result in retinal damage of the exposed eye. (author)

  13. Eye position signals modify vestibulo- and cervico-ocular fast phases during passive yaw rotations in humans.

    Science.gov (United States)

    Anastasopoulos, D; Mandellos, D; Kostadima, V; Pettorossi, V E

    2002-08-01

    We studied the amplitude, latency, and probability of occurrence of fast phases (FP) in darkness to unpredictable vestibular and/or cervical yaw stimulation in normal human subjects. The rotational stimuli were smoothed trapezoidal motion transients of 14 degrees amplitude and 1.25 s duration. Eye position before stimulus application (initial eye position, IEP) was introduced as a variable by asking the subjects to fixate a spot appearing either straight ahead or at 7 degrees eccentric positions. The recordings demonstrated that the generation of FP during vestibular stimulation was facilitated when the whole-body rotation was directed opposite the eccentric IEP. Conversely, FP were attenuated if the whole-body rotation was directed toward the eccentric IEP; i.e., the FP attenuated if they were made to further eccentric positions. Cervical stimulation-induced FP were small and variable in direction when IEP was directed straight ahead before stimulus onset. Eccentric IEPs resulted in large FP, the direction of which was essentially independent of the neck-proprioceptive stimulus. They tended to move the eye toward the primary position, both when the trunk motion under the stationary head was directed toward or away from the IEP. FP dependence on IEP was evident also during head-on-trunk rotations. No consistent interaction between vestibularly and cervically induced FP was found. We conclude that extraretinal eye position signals are able to modify vestibularly evoked reflexive FP in darkness, aiming at minimizing excursions of the eyes away from the primary position. However, neck-induced FP do not relate to specific tasks of stabilization or visual search. By keeping the eyes near the primary position, FP may permit flexibility of orienting responses to incoming stimuli. This recentering bias for both vestibularly and cervically generated FP may represent a visuomotor optimizing strategy.

  14. Human Response to Ductless Personalised Ventilation: Impact of Air Movement, Temperature and Cleanness on Eye Symptoms

    DEFF Research Database (Denmark)

    Dalewski, Mariusz; Fillon, Maelys; Bivolarova, Maria

    2013-01-01

    environment facially applied individually controlled air movement of room air, with or without local filtering, did not have significant impact on eye blink frequency and tear film quality. The local air movement and air cleaning resulted in increased eye blinking frequency and improvement of tear film......The performance of ductless personalized ventilation (DPV) in conjunction with displacement ventilation (DV) was studied in relation to peoples’ health, comfort and performance. This paper presents results on the impact of room air temperature, using of DPV and local air filtration on eye blink...

  15. Blue eye color in humans may be caused by a perfectly associated founder mutation in a regulatory element located within the HERC2 gene inhibiting OCA2 expression

    DEFF Research Database (Denmark)

    Eiberg, Hans; Troelsen, Jesper; Boyd, Mette

    2008-01-01

    The human eye color is a quantitative trait displaying multifactorial inheritance. Several studies have shown that the OCA2 locus is the major contributor to the human eye color variation. By linkage analysis of a large Danish family, we finemapped the blue eye color locus to a 166 Kbp region...... within the HERC2 gene. By association analyses, we identified two SNPs within this region that were perfectly associated with the blue and brown eye colors: rs12913832 and rs1129038. Of these, rs12913832 is located 21.152 bp upstream from the OCA2 promoter in a highly conserved sequence in intron 86...... founder mutation in an OCA2 inhibiting regulatory element as the cause of blue eye color in humans. In addition, an LOD score of Z = 4.21 between hair color and D14S72 was obtained in the large family, indicating that RABGGTA is a candidate gene for hair color....

  16. Integrative annotation of 21,037 human genes validated by full-length cDNA clones.

    Directory of Open Access Journals (Sweden)

    Tadashi Imanishi

    2004-06-01

    Full Text Available The human genome sequence defines our inherent biological potential; the realization of the biology encoded therein requires knowledge of the function of each gene. Currently, our knowledge in this area is still limited. Several lines of investigation have been used to elucidate the structure and function of the genes in the human genome. Even so, gene prediction remains a difficult task, as the varieties of transcripts of a gene may vary to a great extent. We thus performed an exhaustive integrative characterization of 41,118 full-length cDNAs that capture the gene transcripts as complete functional cassettes, providing an unequivocal report of structural and functional diversity at the gene level. Our international collaboration has validated 21,037 human gene candidates by analysis of high-quality full-length cDNA clones through curation using unified criteria. This led to the identification of 5,155 new gene candidates. It also manifested the most reliable way to control the quality of the cDNA clones. We have developed a human gene database, called the H-Invitational Database (H-InvDB; http://www.h-invitational.jp/. It provides the following: integrative annotation of human genes, description of gene structures, details of novel alternative splicing isoforms, non-protein-coding RNAs, functional domains, subcellular localizations, metabolic pathways, predictions of protein three-dimensional structure, mapping of known single nucleotide polymorphisms (SNPs, identification of polymorphic microsatellite repeats within human genes, and comparative results with mouse full-length cDNAs. The H-InvDB analysis has shown that up to 4% of the human genome sequence (National Center for Biotechnology Information build 34 assembly may contain misassembled or missing regions. We found that 6.5% of the human gene candidates (1,377 loci did not have a good protein-coding open reading frame, of which 296 loci are strong candidates for non-protein-coding RNA

  17. Neurophysiological aspects of eye and eyelid movements during blinking in humans

    NARCIS (Netherlands)

    Bour, L. J.; Aramideh, M.; de Visser, B. W.

    2000-01-01

    The neural relationships between eyelid movements and eye movements during spontaneous, voluntary, and reflex blinking in a group of healthy subjects were examined. Electromyographic (EMG) recording of the orbicularis oculi (OO) muscles was performed using surface electrodes. Concurrently,

  18. Eye safety report 2 (355 nm). Human risk analysis simulator for space lidars

    International Nuclear Information System (INIS)

    Schulmeister, K.; Mellerio, J.; Sonneck, G.

    2001-09-01

    This report contains the results of a risk study for a satellite based lidar mission that uses a laser in the ultraviolet wavelength range to measure atmospheric properties. A lidar can be considered as a laser radar and is an acronym for light detection and ranging. The lidar measures properties of the atmosphere by analysis of laser radiation that is directed back to the lidar. As only part of the laser radiation is scattered or absorbed by the atmosphere, the remaining laser radiation emitted from the spacecraft is incident on the earth's surface, where it might lead to injuries, especially to the eye, if biological thresholds are exceeded. For the analysed mission there is no hazard to the skin, only a potential one to the eye, but only if ocular exposure occurs with very large telescopes. The wavelength of the laser is 355 nm, which is absorbed by the cornea and lens of the eye. That is, it is not focussed onto the retina of the eye as, for instance, visible wavelengths, and therefore comparatively high levels of laser exposure, are needed to produce an injury in the lens and cornea. Because the footprint of the satellite's laser beam on the surface of the earth is so small and it moves so fast, the chance of the naked eye being exposed to the laser is small. Because of the magnification provided by an optical instrument, and the concomitant reduction in the field of view, the probability of exposure of an eye that is using such an instrument decreases with increasing optical power. However, because an increased optical power implies increased diameter of the light gathering optics, the laser energy delivered to an eye increases with instrument size so that if exposure did occur, the probability of delivering energy to the eye that exceeds the thresholds for damage increases. There are thus two conflicting processes at work for viewing with optical instruments: an increase in diameter increases the energy delivered but reduces the probability of lidar beam

  19. Shared sensory estimates for human motion perception and pursuit eye movements.

    Science.gov (United States)

    Mukherjee, Trishna; Battifarano, Matthew; Simoncini, Claudio; Osborne, Leslie C

    2015-06-03

    Are sensory estimates formed centrally in the brain and then shared between perceptual and motor pathways or is centrally represented sensory activity decoded independently to drive awareness and action? Questions about the brain's information flow pose a challenge because systems-level estimates of environmental signals are only accessible indirectly as behavior. Assessing whether sensory estimates are shared between perceptual and motor circuits requires comparing perceptual reports with motor behavior arising from the same sensory activity. Extrastriate visual cortex both mediates the perception of visual motion and provides the visual inputs for behaviors such as smooth pursuit eye movements. Pursuit has been a valuable testing ground for theories of sensory information processing because the neural circuits and physiological response properties of motion-responsive cortical areas are well studied, sensory estimates of visual motion signals are formed quickly, and the initiation of pursuit is closely coupled to sensory estimates of target motion. Here, we analyzed variability in visually driven smooth pursuit and perceptual reports of target direction and speed in human subjects while we manipulated the signal-to-noise level of motion estimates. Comparable levels of variability throughout viewing time and across conditions provide evidence for shared noise sources in the perception and action pathways arising from a common sensory estimate. We found that conditions that create poor, low-gain pursuit create a discrepancy between the precision of perception and that of pursuit. Differences in pursuit gain arising from differences in optic flow strength in the stimulus reconcile much of the controversy on this topic. Copyright © 2015 the authors 0270-6474/15/358515-16$15.00/0.

  20. Dwarf Eye Disorder

    Science.gov (United States)

    Science Teacher, 2005

    2005-01-01

    Johns Hopkins researchers at the Wilmer Eye Institute have discovered what appears to be the first human gene mutation that causes extreme farsightedness. The researchers report that nanophthalmos, Greek for "dwarf eye," is a rare, potentially blinding disorder caused by an alteration in a gene called MFRP that helps control eye growth and…

  1. Eye Allergies

    Science.gov (United States)

    ... Español Eye Health / Eye Health A-Z Eye Allergies Sections What Are Eye Allergies? Eye Allergy Symptoms ... allergy diagnosis Eye allergy treatment What Are Eye Allergies? Leer en Español: ¿Qué son las alergias de ...

  2. Human uroporphyrinogen III synthase: Molecular cloning, nucleotide sequence, and expression of a full-length cDNA

    International Nuclear Information System (INIS)

    Tsai, Shihfeng; Bishop, D.F.; Desnick, R.J.

    1988-01-01

    Uroporphyrinogen III synthase, the fourth enzyme in the heme biosynthetic pathway, is responsible for conversion of the linear tetrapyrrole, hydroxymethylbilane, to the cyclic tetrapyrrole, uroporphyrinogen III. The deficient activity of URO-synthase is the enzymatic defect in the autosomal recessive disorder congenital erythropoietic porphyria. To facilitate the isolation of a full-length cDNA for human URO-synthase, the human erythrocyte enzyme was purified to homogeneity and 81 nonoverlapping amino acids were determined by microsequencing the N terminus and four tryptic peptides. Two synthetic oligonucleotide mixtures were used to screen 1.2 x 10 6 recombinants from a human adult liver cDNA library. Eight clones were positive with both oligonucleotide mixtures. Of these, dideoxy sequencing of the 1.3 kilobase insert from clone pUROS-2 revealed 5' and 3' untranslated sequences of 196 and 284 base pairs, respectively, and an open reading frame of 798 base pairs encoding a protein of 265 amino acids with a predicted molecular mass of 28,607 Da. The isolation and expression of this full-length cDNA for human URO-synthase should facilitate studies of the structure, organization, and chromosomal localization of this heme biosynthetic gene as well as the characterization of the molecular lesions causing congenital erythropoietic porphyria

  3. Single Stem Cell Imaging and Analysis Reveals Telomere Length Differences in Diseased Human and Mouse Skeletal Muscles

    Directory of Open Access Journals (Sweden)

    Elisia D. Tichy

    2017-10-01

    Full Text Available Muscle stem cells (MuSCs contribute to muscle regeneration following injury. In many muscle disorders, the repeated cycles of damage and repair lead to stem cell dysfunction. While telomere attrition may contribute to aberrant stem cell functions, methods to accurately measure telomere length in stem cells from skeletal muscles have not been demonstrated. Here, we have optimized and validated such a method, named MuQ-FISH, for analyzing telomere length in MuSCs from either mice or humans. Our analysis showed no differences in telomere length between young and aged MuSCs from uninjured wild-type mice, but MuSCs isolated from young dystrophic mice exhibited significantly shortened telomeres. In corroboration, we demonstrated that telomere attrition is present in human dystrophic MuSCs, which underscores its importance in diseased regenerative failure. The robust technique described herein provides analysis at a single-cell resolution and may be utilized for other cell types, especially rare populations of cells.

  4. Human rather than ape-like orbital morphology allows much greater lateral visual field expansion with eye abduction

    Science.gov (United States)

    Denion, Eric; Hitier, Martin; Levieil, Eric; Mouriaux, Frédéric

    2015-01-01

    While convergent, the human orbit differs from that of non-human apes in that its lateral orbital margin is significantly more rearward. This rearward position does not obstruct the additional visual field gained through eye motion. This additional visual field is therefore considered to be wider in humans than in non-human apes. A mathematical model was designed to quantify this difference. The mathematical model is based on published computed tomography data in the human neuro-ocular plane (NOP) and on additional anatomical data from 100 human skulls and 120 non-human ape skulls (30 gibbons; 30 chimpanzees / bonobos; 30 orangutans; 30 gorillas). It is used to calculate temporal visual field eccentricity values in the NOP first in the primary position of gaze then for any eyeball rotation value in abduction up to 45° and any lateral orbital margin position between 85° and 115° relative to the sagittal plane. By varying the lateral orbital margin position, the human orbit can be made “non-human ape-like”. In the Pan-like orbit, the orbital margin position (98.7°) was closest to the human orbit (107.1°). This modest 8.4° difference resulted in a large 21.1° difference in maximum lateral visual field eccentricity with eyeball abduction (Pan-like: 115°; human: 136.1°). PMID:26190625

  5. Connecting eye to eye

    DEFF Research Database (Denmark)

    Dau, Susanne; Rask, Anders Bindslev

    2017-01-01

    Computer Supported Collaborative Learning (CSCL) is used a frame for supporting online and blended learning in educations. The online communication and collaboration are afforded by the social collaboration. However, the social collaboration is based on the establishment of direct eye contact...... (Khalid, Deska & Hugenberg, 2016), but direct eye contact is challenged by the position of the digital devices and thus CSCL. Lack of eye contact is the chief contributor to the negative effects of online disinhibition (Lapidot-Lefler & Barak, 2012) and the problem is the location of the web camera...... at the computer. Eye contact is challenged by the displacement between the senders´ and receivers´ focus on the screen picture and the camera's location at the top or bottom of screens on all digital devices. The aim of this paper is accordingly to investigate the influence of the displacement in eye contact...

  6. Influence of physical activity in length of life of the human population in the context of changes

    Directory of Open Access Journals (Sweden)

    Ahmetović Zlatko

    2014-01-01

    Full Text Available Since the middle of the last century, the human population has increased exponentially. This trend is evident today. Human population has, for more than half a century been undergoing the period of its intensive development, increasing in number and the average length of life, creating the impression of a better life standard. Looking at the man as a bio-psycho-social being and the interactions it ones through the human population growth is brought in connection with its impact on the environment. In such an environment, one does not only face infectious diseases, but also the misery and poverty in developing countries and massive noninfectious diseases, in developed countries. These facts introduce evidence about the possible effects of physical activity as to prevent the consequences of mass noninfectious diseases, as well as to strengthen the competence of people in general. Therefore, in a holistic, synergic concept of interpretation of human life, it is significant to include biological indicators that have an impact on the growth of the world population and may be associated with the kinesiology. Quantitative indicators of the trend of human development on this planet are the basic research unit observed in this paper. At the same time, the subjects of observation are also other indicators that can be causally linked to the development of the human population and are especially valuable evidence of the contribution of physical activity to the human development. The data that is associated with the theoretical considerations and the results of various statistics are presented based on the rules of ex-post-facto analysis. It is concluded that the value of physical activity has long had to have the equal status with one's chances of being better prepared for life on this planet ontogenetically and phylogenetically, and for the life conditions that will become even more extreme and that increasing older humans will face.

  7. Application of SV40 T-transformed human corneal epithelial cells to evaluate potential irritant chemicals for in vitro alternative eye toxicity.

    Science.gov (United States)

    Kim, Cho-Won; Park, Geon-Tae; Bae, Ok-Nam; Noh, Minsoo; Choi, Kyung-Chul

    2016-01-01

    Assessment of eye irritation potential is important to human safety, and it is necessary for various cosmetics and chemicals that may contact the human eye. Until recently, the Draize test was considered the standard method for estimating eye irritation, despite its disadvantages such as the need to sacrifice many rabbits for subjective scoring. Thus, we investigated the cytotoxicity and inflammatory response to standard eye irritants using SV40 T-transformed human corneal epithelial (SHCE) cells as a step toward development of an animal-free alternative eye irritation test. MTT and NRU assays of cell viability were performed to investigate the optimal experimental conditions for SHCE cell viability when cells were exposed to sodium dodecyl sulfate (SDS) as a standard eye irritant at 6.25×10(-3) to 1×10(-1)%. Additionally, cell viability of SHCE cells was examined in response to six potential eye irritants, benzalkonium chloride, dimethyl sulfoxide, isopropanol, SDS, Triton X-100 and Tween 20 at 5×10(-3) to 1×10(-1)%. Finally, we estimated the secretion level of cytokines in response to stimulation by eye irritants in SHCE cells. SHCE cells showed a good response to potential eye irritants when the cells were exposed to potential irritants for 10min at room temperature (RT), and cytokine production increased in a concentration-dependent manner, indicating that cytotoxicity and cytokine secretion from SHCE cells may be well correlated with the concentrations of irritants. Taken together, these results suggest that SHCE cells could be an excellent alternative in vitro model to replace in vivo animal models for eye irritation tests. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Influence of the corneal optical zone on the point-spread function of the human eye

    Science.gov (United States)

    Rol, Pascal O.; Parel, Jean-Marie A.

    1992-08-01

    In refractive surgery, a number of surgical techniques have been developed to correct ametropia (refractive defaults) of the eye by changing the exterior shape of the cornea. Because the air-cornea interface makes up for about two thirds of the refractive power of the eye, a refractive correction can be obtained by a suitable reshaping of the cornea. Postoperatively, it is usually observed that the corneal region consists of two or more zones which are characterized by different optical parameters exhibiting in particular different focal distances. Under normal circumstances, only the central area of the cornea is involved in the formation of the retinal image. However, if part of the light entering the eye through peripheral portions of the cornea with refractive properties different from the central area can pass the pupil, an out-of-focus `ghost' image may be overlaid on the retina causing a blur. In such a case the resolution, and the contrast performance of the eye which is expected from a successful operation, may be reduced. This study is an attempt to quantify the vision blur as a function of the diameter of the central zone, i.e., the optical zone which is of importance for vision.

  9. Spherical and irregular aberrations are important for the optimal performance of the human eye

    NARCIS (Netherlands)

    Nio, YK; Jansonius, NM; Fidler, [No Value; Geraghty, E; Norrby, S; Kooijman, AC

    Contrast sensitivity measured psychophysically at different levels of defocus can be used to evaluate the eye optics. Possible parameters of spherical and irregular aberrations, e.g, relative modulation transfer (RMT), myopic shift, and depth of focus, can be determined from these measurements. The

  10. Eye-head stabilization mechanism for a humanoid robot tested on human inertial data

    DEFF Research Database (Denmark)

    Vannucci, Lorenzo; Falotico, Egidio; Tolu, Silvia

    2016-01-01

    they keep the image stationary on the retina. In this work we present the first complete model of eye-head stabilization based on the coordination of VCR and VOR. The model is provided with learning and adaptation capabilities based on internal models. Tests on a simulated humanoid platform replicating...

  11. Telomere length dynamics in human memory T cells specific for viruses causing acute or latent infections.

    Science.gov (United States)

    O'Bryan, Joel M; Woda, Marcia; Co, Mary; Mathew, Anuja; Rothman, Alan L

    2013-08-26

    Declining telomere length (TL) is associated with T cell senescence. While TL in naïve and memory T cells declines with increasing age, there is limited data on TL dynamics in virus-specific memory CD4+ T cells in healthy adults. We combined BrdU-labeling of virus-stimulated T cells followed with flow cytometry-fluorescent in situ hybridization for TL determination. We analyzed TL in T cells specific for several virus infections: non-recurring acute (vaccinia virus, VACV), recurring-acute (influenza A virus, IAV), and reactivating viruses (varicella-zoster virus, VZV, and cytomegalovirus, CMV) in 10 healthy subjects. Additionally, five subjects provided multiple blood samples separated by up to 10 years. VACV- and CMV-specific T cells had longer average TL than IAV-specific CD4+ T cells. Although most virus-specific cells were CD45RA-, we observed a minor population of BrdU+ CD45RA+ T cells characterized by long telomeres. Longitudinal analysis demonstrated a slow decline in average TL in virus-specific T cells. However, in one subject, VZV reactivation led to an increase in average TL in VZV-specific memory T cells, suggesting a conversion of longer TL cells from the naïve T cell repertoire. TLs in memory CD4+ T cells in otherwise healthy adults are heterogeneous and follow distinct virus-specific kinetics. These findings suggests that the distribution of TL and the creation and maintenance of long TL memory T cells could be important for the persistence of long-lived T cell memory.

  12. Eye Irritation Test (EIT) for Hazard Identification of Eye Irritating Chemicals using Reconstructed Human Cornea-like Epithelial (RhCE) Tissue Model.

    Science.gov (United States)

    Kaluzhny, Yulia; Kandárová, Helena; d'Argembeau-Thornton, Laurence; Kearney, Paul; Klausner, Mitchell

    2015-08-23

    To comply with the Seventh Amendment to the EU Cosmetics Directive and EU REACH legislation, validated non-animal alternative methods for reliable and accurate assessment of ocular toxicity in man are needed. To address this need, we have developed an eye irritation test (EIT) which utilizes a three dimensional reconstructed human cornea-like epithelial (RhCE) tissue model that is based on normal human cells. The EIT is able to separate ocular irritants and corrosives (GHS Categories 1 and 2 combined) and those that do not require labeling (GHS No Category). The test utilizes two separate protocols, one designed for liquid chemicals and a second, similar protocol for solid test articles. The EIT prediction model uses a single exposure period (30 min for liquids, 6 hr for solids) and a single tissue viability cut-off (60.0% as determined by the MTT assay). Based on the results for 83 chemicals (44 liquids and 39 solids) EIT achieved 95.5/68.2/ and 81.8% sensitivity/specificity and accuracy (SS&A) for liquids, 100.0/68.4/ and 84.6% SS&A for solids, and 97.6/68.3/ and 83.1% for overall SS&A. The EIT will contribute significantly to classifying the ocular irritation potential of a wide range of liquid and solid chemicals without the use of animals to meet regulatory testing requirements. The EpiOcular EIT method was implemented in 2015 into the OECD Test Guidelines as TG 492.

  13. PCB153 reduces telomerase activity and telomere length in immortalized human skin keratinocytes (HaCaT) but not in human foreskin keratinocytes (NFK)

    International Nuclear Information System (INIS)

    Senthilkumar, P.K.; Robertson, L.W.; Ludewig, G.

    2012-01-01

    Polychlorinated biphenyls (PCBs), ubiquitous environmental pollutants, are characterized by long term-persistence in the environment, bioaccumulation, and biomagnification in the food chain. Exposure to PCBs may cause various diseases, affecting many cellular processes. Deregulation of the telomerase and the telomere complex leads to several biological disorders. We investigated the hypothesis that PCB153 modulates telomerase activity, telomeres and reactive oxygen species resulting in the deregulation of cell growth. Exponentially growing immortal human skin keratinocytes (HaCaT) and normal human foreskin keratinocytes (NFK) were incubated with PCB153 for 48 and 24 days, respectively, and telomerase activity, telomere length, superoxide level, cell growth, and cell cycle distribution were determined. In HaCaT cells exposure to PCB153 significantly reduced telomerase activity, telomere length, cell growth and increased intracellular superoxide levels from day 6 to day 48, suggesting that superoxide may be one of the factors regulating telomerase activity, telomere length and cell growth compared to untreated control cells. Results with NFK cells showed no shortening of telomere length but reduced cell growth and increased superoxide levels in PCB153-treated cells compared to untreated controls. As expected, basal levels of telomerase activity were almost undetectable, which made a quantitative comparison of treated and control groups impossible. The significant down regulation of telomerase activity and reduction of telomere length by PCB153 in HaCaT cells suggest that any cell type with significant telomerase activity, like stem cells, may be at risk of premature telomere shortening with potential adverse health effects for the affected organism. -- Highlights: ► Human immortal (HaCaT) and primary (NFK) keratinocytes were exposed to PCB153. ► PCB153 significantly reduced telomerase activity and telomere length in HaCaT. ► No effect on telomere length and

  14. Dose conversion coefficients for electron exposure of the human eye lens

    International Nuclear Information System (INIS)

    Behrens, R; Dietze, G; Zankl, M

    2009-01-01

    Recent epidemiological studies suggest a rather low dose threshold (below 0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimized and current dose limits for the eye lens may be reduced in the future. Two questions arise from this situation: first, which dose quantity is related to the risk of developing a cataract, and second, which personal dose equivalent quantity is appropriate for monitoring this dose quantity. While the dose equivalent quantity H p (0.07) has often been seen as being sufficiently accurate for monitoring the dose to the lens of the eye, this would be questionable in the case when the dose limits were reduced and, thus, it may be necessary to generally use the dose equivalent quantity H p (3) for this purpose. The basis for a decision, however, must be the knowledge of accurate conversion coefficients from fluence to equivalent dose to the lens. This is especially important for low-penetrating radiation, for example, electrons. Formerly published values of conversion coefficients are based on quite simple models of the eye. In this paper, quite a sophisticated model of the eye including the inner structure of the lens was used for the calculations and precise conversion coefficients for electrons with energies between 0.2 MeV and 12 MeV, and for angles of radiation incidence between 0 deg. and 45 deg. are presented. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are up to 1000 times smaller for electron energies below 1 MeV, nearly equal at 1 MeV and above 4 MeV, and by a factor of 1.5 larger at about 1.5 MeV electron energy.

  15. RESEARCH OF LINEAR AND NONLINEAR PROCESSES AT FEMTOSECOND LASER RADIATION PROPAGATION IN THE MEDIUM SIMULATING THE HUMAN EYE VITREOUS

    Directory of Open Access Journals (Sweden)

    P. Y. Rogov

    2015-09-01

    Full Text Available The paper deals with mathematical model of linear and nonlinear processes occurring at the propagation of femtosecond laser pulses in the vitreous of the human eye. Methods of computing modeling are applied for the nonlinear spectral equation solution describing the dynamics of a two-dimensional TE-polarized radiation in a homogeneous isotropic medium with cubic fast-response nonlinearity without the usage of slowly varying envelope approximation. Environments close to the optical media parameters of the eye were used for the simulation. The model of femtosecond radiation propagation takes into account the process dynamics for dispersion broadening of pulses in time and the occurence of the self-focusing near the retina when passing through the vitreous body of the eye. Dependence between the pulse duration on the retina has been revealed and the duration of the input pulse and the values of power density at which there is self-focusing have been found. It is shown that the main mechanism of radiation damage with the use of titanium-sapphire laser is photoionization. The results coincide with those obtained by the other scientists, and are usable for creation Russian laser safety standards for femtosecond laser systems.

  16. Setting targets for human resources for eye health in sub-Saharan Africa: what evidence should be used?

    Science.gov (United States)

    Courtright, Paul; Mathenge, Wanjiku; Kello, Amir Bedri; Cook, Colin; Kalua, Khumbo; Lewallen, Susan

    2016-03-16

    With a global target set at reducing vision loss by 25% by the year 2019, sub-Saharan Africa with an estimated 4.8 million blind persons will require human resources for eye health (HReH) that need to be available, appropriately skilled, supported, and productive. Targets for HReH are useful for planning, monitoring, and resource mobilization, but they need to be updated and informed by evidence of effectiveness and efficiency. Supporting evidence should take into consideration (1) ever-changing disease-specific issues including the epidemiology, the complexity of diagnosis and treatment, and the technology needed for diagnosis and treatment of each condition; (2) the changing demands for vision-related services of an increasingly urbanized population; and (3) interconnected health system issues that affect productivity and quality. The existing targets for HReH and some of the existing strategies such as task shifting of cataract surgery and trichiasis surgery, as well as the scope of eye care interventions for primary eye care workers, will need to be re-evaluated and re-defined against such evidence or supported by new evidence.

  17. Amyloid structure exhibits polymorphism on multiple length scales in human brain tissue

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jiliang; Costantino, Isabel; Venugopalan, Nagarajan; Fischetti, Robert F.; Hyman, Bradley; Frosch, Matthew; Gomez-Isla, Teresa; Makowski, Lee

    2016-09-15

    Although aggregation of Aβ amyloid fibrils into plaques in the brain is a hallmark of Alzheimer's Disease (AD), the correlation between amyloid burden and severity of symptoms is weak. One possible reason is that amyloid fibrils are structurally polymorphic and different polymorphs may contribute differentially to disease. However, the occurrence and distribution of amyloid polymorphisms in human brain is poorly documented. Here we seek to fill this knowledge gap by using X-ray microdiffraction of histological sections of human tissue to map the abundance, orientation and structural heterogeneities of amyloid within individual plaques; among proximal plaques and in subjects with distinct clinical histories. A 5 µ x-ray beam was used to generate diffraction data with each pattern arising from a scattering volume of only ~ 450 µ3 , making possible collection of dozens to hundreds of diffraction patterns from a single amyloid plaque. X-ray scattering from these samples exhibited all the properties expected for scattering from amyloid. Amyloid distribution was mapped using the intensity of its signature 4.7 Å reflection which also provided information on the orientation of amyloid fibrils across plaques. Margins of plaques exhibited a greater degree of orientation than cores and orientation around blood vessels frequently appeared tangential. Variation in the structure of Aβ fibrils is reflected in the shape of the 4.7 Å peak which usually appears as a doublet. Variations in this peak correspond to differences between the structure of amyloid within cores of plaques and at their periphery. Examination of tissue from a mismatch case - an individual with high plaque burden but no overt signs of dementia at time of death - revealed a diversity of structure and spatial distribution of amyloid that is distinct from typical AD cases. We demonstrate the existence of structural polymorphisms among amyloid within and among plaques of a single individual and suggest

  18. The effect of gaze angle on the evaluations of SAR and temperature rise in human eye under plane-wave exposures from 0.9 to 10 GHz

    International Nuclear Information System (INIS)

    Diao, Yinliang; Leung, Sai-Wing; Sun, Weinong; Siu, Yun-Ming; Kong, Richard; Hung Chan, Kwok

    2016-01-01

    This article investigates the effect of gaze angle on the specific absorption rate (SAR) and temperature rise in human eye under electromagnetic exposures from 0.9 to 10 GHz. Eye models in different gaze angles are developed based on bio-metric data. The spatial-average SARs in eyes are investigated using the finite-difference time-domain method, and the corresponding maximum temperature rises in lens are calculated by the finite-difference method. It is found that the changes in the gaze angle produce a maximum variation of 35, 12 and 20 % in the eye-averaged SAR, peak 10 g average SAR and temperature rise, respectively. Results also reveal that the eye-averaged SAR is more sensitive to the changes in the gaze angle than peak 10 g average SAR, especially at higher frequencies. (authors)

  19. Three-dimensional ray tracing in spherical and elliptical generalized Luneburg lenses for application in the human eye lens.

    Science.gov (United States)

    Gómez-Correa, J E; Coello, V; Garza-Rivera, A; Puente, N P; Chávez-Cerda, S

    2016-03-10

    Ray tracing in spherical Luneburg lenses has always been represented in 2D. All propagation planes in a 3D spherical Luneburg lens generate the same ray tracing, due to its radial symmetry. A geometry without radial symmetry generates a different ray tracing. For this reason, a new ray tracing method in 3D through spherical and elliptical Luneburg lenses using 2D methods is proposed. The physics of the propagation is shown here, which allows us to make a ray tracing associated with a vortex beam. A 3D ray tracing in a composite modified Luneburg lens that represents the human eye lens is also presented.

  20. Isolation and characterization of full-length cDNA clones coding for cholinesterase from fetal human tissues

    International Nuclear Information System (INIS)

    Prody, C.A.; Zevin-Sonkin, D.; Gnatt, A.; Goldberg, O.; Soreq, H.

    1987-01-01

    To study the primary structure and regulation of human cholinesterases, oligodeoxynucleotide probes were prepared according to a consensus peptide sequence present in the active site of both human serum pseudocholinesterase and Torpedo electric organ true acetylcholinesterase. Using these probes, the authors isolated several cDNA clones from λgt10 libraries of fetal brain and liver origins. These include 2.4-kilobase cDNA clones that code for a polypeptide containing a putative signal peptide and the N-terminal, active site, and C-terminal peptides of human BtChoEase, suggesting that they code either for BtChoEase itself or for a very similar but distinct fetal form of cholinesterase. In RNA blots of poly(A) + RNA from the cholinesterase-producing fetal brain and liver, these cDNAs hybridized with a single 2.5-kilobase band. Blot hybridization to human genomic DNA revealed that these fetal BtChoEase cDNA clones hybridize with DNA fragments of the total length of 17.5 kilobases, and signal intensities indicated that these sequences are not present in many copies. Both the cDNA-encoded protein and its nucleotide sequence display striking homology to parallel sequences published for Torpedo AcChoEase. These finding demonstrate extensive homologies between the fetal BtChoEase encoded by these clones and other cholinesterases of various forms and species

  1. Lens oscillations in the human eye. Implications for post-saccadic suppression of vision.

    Directory of Open Access Journals (Sweden)

    Juan Tabernero

    Full Text Available The eye changes gaze continuously from one visual stimulus to another. Using a high speed camera to record eye and lens movements we demonstrate how the crystalline lens sustains an inertial oscillatory decay movement immediately after every change of gaze. This behavior fit precisely with the movement of a classical damped harmonic oscillator. The time course of the oscillations range from 50 to 60 msec with an oscillation frequency of around 20 Hz. That has dramatic implications on the image quality at the retina on the very short times (∼50 msec that follow the movement. However, it is well known that our vision is nearly suppressed on those periods (post-saccadic suppression. Both phenomenon follow similar time courses and therefore might be synchronized to avoid the visual impairment.

  2. Ultrastructural effects of silicone oil on the clear crystalline lens of the human eye.

    Science.gov (United States)

    Soliman, Wael; Sharaf, Mohamed; Abdelazeem, Khaled; El-Gamal, Dalia; Nafady, Allam

    2018-03-01

    To evaluate light and electron microscopic changes of the anterior capsule and its epithelium after clear lens extraction of vitrectomized myopic eyes with silicone oil tamponade. This prospective, controlled, non-randomized, interventional study included 20 anterior lens capsular specimens that were excised during combined clear lens extraction and silicone oil removal from previously vitrectomized highly myopic patients with silicone oil tamponade for previous retinal detachment surgeries. The specimens were examined via light microscopy and electron microscopy and compared with 20 anterior capsule specimens removed during clear lens extraction of non-vitrectomized highly myopic eyes. Light microscopic examination of clear lens anterior capsule specimens of vitrectomized myopic eyes filled with silicone oil showed relatively more flat cells with irregular outline of lens' epithelial cells with wide intercellular spaces, deeply stained nuclei, and multiple intracytoplasmic vacuoles. Scanning electron microscopy revealed collagenous surfaces filled with multiple pits, depressions, and abnormal deposits. Transmission electron microscopy revealed lens epithelial cells with apoptotic changes, many cytoplasmic vacuoles, and filopodia-like protrusions between lens epithelial cells and the capsule. Epithelial proliferation and multilayering were also observed. silicone oil may play a role in the development of apoptotic and histopathological changes in clear lens epithelial cells. Clarity of the lens at the time of silicone oil removal does not indicate an absence of cataractous changes. We found justification of combined clear lens extraction and silicone oil removal or combined phacovitrectomy when silicone oil injection is planned, but further long-term studies with larger patient groups are required.

  3. Establishment of a new in vitro test method for evaluation of eye irritancy using a reconstructed human corneal epithelial model, LabCyte CORNEA-MODEL.

    Science.gov (United States)

    Katoh, Masakazu; Hamajima, Fumiyasu; Ogasawara, Takahiro; Hata, Ken-ichiro

    2013-12-01

    Finding in vitro eye irritation testing alternatives to animal testing such as the Draize eye test, which uses rabbits, is essential from the standpoint of animal welfare. It has been developed a reconstructed human corneal epithelial model, the LabCyte CORNEA-MODEL, which has a representative corneal epithelium-like structure. Protocol optimization (pre-validation study) was examined in order to establish a new alternative method for eye irritancy evaluation with this model. From the results of the optimization experiments, the application periods for chemicals were set at 1min for liquid chemicals or 24h for solid chemicals, and the post-exposure incubation periods were set at 24h for liquids or zero for solids. If the viability was less than 50%, the chemical was judged to be an eye irritant. Sixty-one chemicals were applied in the optimized protocol using the LabCyte CORNEA-MODEL and these results were evaluated in correlation with in vivo results. The predictions of the optimized LabCyte CORNEA-MODEL eye irritation test methods were highly correlated with in vivo eye irritation (sensitivity 100%, specificity 80.0%, and accuracy 91.8%). These results suggest that the LabCyte CORNEA-MODEL eye irritation test could be useful as an alternative method to the Draize eye test. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Application of Fluorescent Amplified Fragment Length Polymorphism for Comparison of Human and Animal Isolates of Yersinia enterocolitica

    Science.gov (United States)

    Fearnley, Catherine; On, Stephen L. W.; Kokotovic, Branko; Manning, Georgina; Cheasty, Tom; Newell, Diane G.

    2005-01-01

    An amplified fragment length polymorphism (AFLP) method, developed to genotype Yersinia enterocolitica, has been used to investigate 70 representative strains isolated from humans, pigs, sheep, and cattle in the United Kingdom. AFLP primarily distinguished Y. enterocolitica strains according to their biotype, with strains dividing into two distinct clusters: cluster A, comprising largely the putatively pathogenic biotypes (BT2 to -4), and cluster B, comprising the putatively nonpathogenic biotype 1A strains and a single BT1B isolate. Within these two clusters, subclusters formed largely on the basis of serotype. However, AFLP profiles also allowed differentiation of strains within these serotype-related subclusters, indicating the high discriminatory power of the technique for Y. enterocolitica. Investigation of the relationship between strain AFLP profile and host confirmed that pigs are, and provides further proof that sheep may be, potential sources of human infection with putatively pathogenic strains. However, the results suggest that some strains causing human disease do not come from veterinary sources identifiable at this time. The distribution of some BT1A isolates within cluster A raises questions about the relationship between virulence potential and biotype. PMID:16151073

  5. Tocotrienol-Rich Fraction Prevents Cell Cycle Arrest and Elongates Telomere Length in Senescent Human Diploid Fibroblasts

    Directory of Open Access Journals (Sweden)

    Suzana Makpol

    2011-01-01

    Full Text Available This study determined the molecular mechanisms of tocotrienol-rich fraction (TRF in preventing cellular senescence of human diploid fibroblasts (HDFs. Primary culture of HDFs at various passages were incubated with 0.5 mg/mL TRF for 24 h. Telomere shortening with decreased telomerase activity was observed in senescent HDFs while the levels of damaged DNA and number of cells in G0/G1 phase were increased and S phase cells were decreased. Incubation with TRF reversed the morphology of senescent HDFs to resemble that of young cells with decreased activity of SA-β-gal, damaged DNA, and cells in G0/G1 phase while cells in the S phase were increased. Elongated telomere length and restoration of telomerase activity were observed in TRF-treated senescent HDFs. These findings confirmed the ability of tocotrienol-rich fraction in preventing HDFs cellular ageing by restoring telomere length and telomerase activity, reducing damaged DNA, and reversing cell cycle arrest associated with senescence.

  6. Ocular surface area and human eye blink frequency during VDU work

    DEFF Research Database (Denmark)

    Nielsen, Pernille Kofoed; Søgaard, Karen; Skotte, Jørgen

    2008-01-01

    . The low BF during the active task was succeded by a burst with high BF after cessation of the active task, indicating a compensatory blinking process. This stresses that interchange of work tasks with different cognitive load is as important as the monitor position in the prevention of visual......The purpose of this study was to investigate how the ocular surface area (OSA) and the eye blink frequency (BF) are affected by a high versus a low-monitor position during visual display unit (VDU) work with varying cognitive demands. In a balanced randomized (2 x 2) design ten healthy subjects...

  7. Human eye cataract microstructure modeling and its effect on simulated retinal imaging

    Science.gov (United States)

    Fan, Wen-Shuang; Chang, Chung-Hao; Horng, Chi-Ting; Yao, Hsin-Yu; Sun, Han-Ying; Huang, Shu-Fang; Wang, Hsiang-Chen

    2017-02-01

    We designed a crystalline microstructure during cataract lesions and calculated the aberration value of the eye by using ray trace modeling to identify the corresponding spherical aberration, coma aberration, and trefoil aberration value under different pathological-change degrees. The mutual relationship between microstructure and aberration was then discussed using these values. Calculation results showed that with increased layer number of microstructure, the influence of aberration value on spherical aberration was the greatest. In addition, the influence of a relatively compact microstructure on spherical aberration and coma aberration was small, but that on trefoil aberration was great.

  8. Identification of cornifelin and early growth response-1 gene as novel biomarkers for in vitro eye irritation using a 3D reconstructed human cornea model MCTT HCE™.

    Science.gov (United States)

    Choi, Seunghye; Lee, Miri; Lee, Su-Hyon; Jung, Haeng-Sun; Kim, Seol-Yeong; Chung, Tae-Young; Choe, Tae-boo; Chun, Young-Jin; Lim, Kyung-Min

    2015-09-01

    Evaluation of the eye irritation is essential in the development of new cosmetic products. Draize rabbit eye irritation test has been widely used in which chemicals are directly applied to rabbit eye, and the symptoms and signs of eyes are scored. However, due to the invasive procedure, it causes substantial pain and discomfort to animals. Recently, we reported in vitro eye irritation test method using a 3D human corneal epithelial model (MCTT HCE™) which is reconstructed from remaining human tissues after a corneal transplantation. This model exhibited an excellent predictive capacity for 25 reference chemicals (sensitivity 100%, specificity 77% and accuracy 88% vs. GHS). To improve the test performance, we explored new biomarkers for the eye irritation through transcriptomic approach. Three surfactants were selected as model eye irritants that include sodium lauryl sulfate, benzalkonium chloride and triton X-100. After test chemicals were treated, we investigated differentially expressed genes through a whole-gene microarray (Affymetrix GeneChip(®) Human Gene 2.0 ST Array, 48,000 probes). As a result, we identified that mRNAs of cornifelin (CNFN), a constituent of the insoluble cornified cell envelope of stratified squamous epithelia, and early growth response-1 (EGR1), a nuclear transcriptional regulator, were significantly up-regulated by all three irritants. Up-regulation of CNFN and EGR1 was further confirmed by Q-RT-PCR, and immunohistochemistry revealed increased level of CNFN in irritant-treated tissues, supporting the relevance of CNFN and EGR1 as new biomarkers for eye irritation.

  9. Comparison of telomere length and association with progenitor cell markers in lacrimal gland between Sjögren syndrome and non-Sjögren syndrome dry eye patients

    Science.gov (United States)

    Kawashima, Motoko; Maida, Yoshiko; Kamoi, Mizuka; Ogawa, Yoko; Shimmura, Shigeto; Masutomi, Kenkichi; Tsubota, Kazuo

    2011-01-01

    Purpose Indicators of aging such as disruption of telomeric function due to shortening may be more frequent in dysfunctional lacrimal gland. The aims of this study were to 1) determine the viability of quantitative fluorescence in situ hybridization of telomeres (telo-FISH) for the assessment of telomere length in lacrimal gland in Sjögren and non- Sjögren syndrome patients; and 2) investigate the relationship between progenitor cell markers and telomere length in both groups. Methods Quantitative fluorescence in situ hybridization with a peptide nucleic acid probe complementary to the telomere repeat sequence was performed on frozen sections from human lacrimal gland tissues. The mean fluorescence intensity of telomere spots was automatically quantified by image analysis as relative telomere length in lacrimal gland epithelial cells. Immunostaining for p63, nucleostemin, ATP-binding cassette, sub-family G, member 2 (ABCG2), and nestin was also performed. Results Telomere intensity in the Sjögren syndrome group (6,785.0±455) was significantly lower than that in the non-Sjögren syndrome group (7,494.7±477; p=0.02). Among the samples from the non-Sjögren syndrome group, immunostaining revealed that p63 was expressed in 1–3 acinar cells in each acinar unit and continuously in the basal layer of duct cells. In contrast, in the Sjögren syndrome group, p63 and nucleostemin showed a lower level of expression. ABCG2 was expressed in acinar cells in both sjogren and non-Sjogren syndrome. Conclusions The results of this study indicate that 1) telo-FISH is a viable method of assessing telomere length in lacrimal gland, and 2) telomere length in Sjögren syndrome is shorter and associated with lower levels of expression of p63 and nucleostemin than in non-Sjögren syndrome. PMID:21655359

  10. Comparison of telomere length and association with progenitor cell markers in lacrimal gland between Sjögren syndrome and non-Sjögren syndrome dry eye patients.

    Science.gov (United States)

    Kawashima, Motoko; Kawakita, Tetsuya; Maida, Yoshiko; Kamoi, Mizuka; Ogawa, Yoko; Shimmura, Shigeto; Masutomi, Kenkichi; Tsubota, Kazuo

    2011-01-01

    Indicators of aging such as disruption of telomeric function due to shortening may be more frequent in dysfunctional lacrimal gland. The aims of this study were to 1) determine the viability of quantitative fluorescence in situ hybridization of telomeres (telo-FISH) for the assessment of telomere length in lacrimal gland in Sjögren and non- Sjögren syndrome patients; and 2) investigate the relationship between progenitor cell markers and telomere length in both groups. Quantitative fluorescence in situ hybridization with a peptide nucleic acid probe complementary to the telomere repeat sequence was performed on frozen sections from human lacrimal gland tissues. The mean fluorescence intensity of telomere spots was automatically quantified by image analysis as relative telomere length in lacrimal gland epithelial cells. Immunostaining for p63, nucleostemin, ATP-binding cassette, sub-family G, member 2 (ABCG2), and nestin was also performed. Telomere intensity in the Sjögren syndrome group (6,785.0±455) was significantly lower than that in the non-Sjögren syndrome group (7,494.7±477; p=0.02). Among the samples from the non-Sjögren syndrome group, immunostaining revealed that p63 was expressed in 1-3 acinar cells in each acinar unit and continuously in the basal layer of duct cells. In contrast, in the Sjögren syndrome group, p63 and nucleostemin showed a lower level of expression. ABCG2 was expressed in acinar cells in both sjogren and non-Sjogren syndrome. The results of this study indicate that 1) telo-FISH is a viable method of assessing telomere length in lacrimal gland, and 2) telomere length in Sjögren syndrome is shorter and associated with lower levels of expression of p63 and nucleostemin than in non-Sjögren syndrome.

  11. Estimation of the in vitro eye irritating and inflammatory potential of lipopolysaccharide (LPS) and dust by using reconstituted human corneal epithelium tissue cultures.

    Science.gov (United States)

    Cao, Yi; Bindslev, Dorthe A; Kjærgaard, Søren K

    2015-01-01

    Eye irritation is a common complaint in indoor environment, but the causes have still not been identified among the multiple exposures in house environments. To identify the potential environmental factors responsible for eye irritation and study the possible mechanisms, an in vitro model for eye irritation is suggested. In this study, reconstituted human corneal epithelium (HCE) tissue cultures were used to study the eye irritating and inflammatory potential of lipopolysaccharide (LPS) and dust. HCE tissue cultures were exposed to a range of concentrations of LPS for 6 h and dust for 24 h, respectively. After exposure, viability and secretion of interleukins (IL) IL-1β, IL-8, and tumor necrosis factor (TNFα) were examined. Histology was used to indicate the morphological changes after dust exposure. Both LPS and dust affected HCE viability. There was an increased level of IL-8 after LPS exposure, while the concentrations of IL-1β and TNFα remained unaffected. Dust exposure resulted in an elevation of both IL-1β and IL-8, but not TNFα. Histology study showed increased vacuolization and reduced thickness after 24 h exposure to 5 mg/mL dust. LPS and dust showed in vitro eye irritating and inflammatory potential, and cytokines/chemokines like IL-1β and IL-8 may be involved in the mechanisms of eye irritation. The HCE tissue culture may be used as an in vitro model to study environmental exposure induced eye irritation and inflammation.

  12. Full-length model of the human galectin-4 and insights into dynamics of inter-domain communication

    Science.gov (United States)

    Rustiguel, Joane K.; Soares, Ricardo O. S.; Meisburger, Steve P.; Davis, Katherine M.; Malzbender, Kristina L.; Ando, Nozomi; Dias-Baruffi, Marcelo; Nonato, Maria Cristina

    2016-09-01

    Galectins are proteins involved in diverse cellular contexts due to their capacity to decipher and respond to the information encoded by β-galactoside sugars. In particular, human galectin-4, normally expressed in the healthy gastrointestinal tract, displays differential expression in cancerous tissues and is considered a potential drug target for liver and lung cancer. Galectin-4 is a tandem-repeat galectin characterized by two carbohydrate recognition domains connected by a linker-peptide. Despite their relevance to cell function and pathogenesis, structural characterization of full-length tandem-repeat galectins has remained elusive. Here, we investigate galectin-4 using X-ray crystallography, small- and wide-angle X-ray scattering, molecular modelling, molecular dynamics simulations, and differential scanning fluorimetry assays and describe for the first time a structural model for human galectin-4. Our results provide insight into the structural role of the linker-peptide and shed light on the dynamic characteristics of the mechanism of carbohydrate recognition among tandem-repeat galectins.

  13. Haplotyping the human T-cell receptor β-chain gene complex by use of restriction fragment length polymorphisms

    International Nuclear Information System (INIS)

    Charmley, P.; Chao, A.; Gatti, R.A.; Concannon, P.; Hood, L.

    1990-01-01

    The authors have studied the genetic segregation of human T-cell receptor β-chain (TCRβ) genes on chromosome 7q in 40 CEPH (Centre d'Etude du Polymorphisme Humain) families by using restriction fragment length polymorphisms (RFLPs). They constructed haplotypes from eight RFLPs by using variable- and constant-region cDNA probes, which detect polymorphisms that span more than 600 kilobases of the TCRβ gene complex. Analysis of allele distributions between TCRβ genes revealed significant linkage disequilibrium between only 6 of the 28 different pairs of RFLPs. This linkage disequilibrium strongly influences the most efficient order to proceed for typing of these RFLPs in order to achieve maximum genetic informativeness, which in this study revealed a 97.3% level of heterozygosity within the TCRβ gene complex. The results should provide new insight into recent reports of disease associations with the TCRβ gene complex and should assist in designing future experiments to detect or confirm the existence of disease-susceptibility loci in this region of the human genome

  14. Relative size of the eye and orbit: an evolutionary and craniofacial constraint model for examining the etiology and disparate incidence of juvenile-onset myopia in humans.

    Science.gov (United States)

    Masters, Michael P

    2012-05-01

    The principal aim of this research is to provide a new model for investigating myopia in humans, and contribute to an understanding of the degree to which modern variation and evolutionary change in orbital and overall craniofacial morphology may help explain the common eye form association with this condition. Recent research into long and short-term evolution of the human orbit reveals a number of changes in this feature, and particularly since the Upper Paleolithic. These include a reduction in orbital depth, a decrease in anterior projection of the upper and lower orbital margins, and most notably, a reduction in orbital volume since the Holocene in East Asia. Reduced orbital volume in this geographic region could exacerbate an existing trend in recent hominin evolution toward larger eyes in smaller orbits, and may help explain the unusually high frequency of myopia in East Asian populations. The objective of the current study is to test a null hypothesis of no relationship between a ratio of orbit to eye volume and spherical equivalent refractive error (SER) in a sample of Chinese adults, and examine how relative size of the eye within the orbit relates to SER between the sexes and across the sample population. Analysis of the orbit, eye, and SER reveals a strong relationship between relative size of the eye within the orbit and the severity of myopic refractive error. An orbit/eye ratio of 3 for females and 3.5 for males (or an eye that occupies approximately 34% and 29% of the orbit, respectively), designates a clear threshold at which myopia develops, and becomes progressively worse as the eye continues to occupy a greater proportion of the orbital cavity. These results indicate that relative size of the eye within the orbit is an important factor in the development of myopia, and suggests that individuals with large eyes in small orbits lack space for adequate development of ocular tissues, leading to compression and distortion of the lithesome globe

  15. A human hemi-cornea model for eye irritation testing: quality control of production, reliability and predictive capacity.

    Science.gov (United States)

    Engelke, M; Zorn-Kruppa, M; Gabel, D; Reisinger, K; Rusche, B; Mewes, K R

    2013-02-01

    We have developed a 3-dimensional human hemi-cornea which comprises an immortalized epithelial cell line and keratocytes embedded in a collagen stroma. In the present study, we have used MTT reduction of the whole tissue to clarify whether the production of this complex 3-D-model is transferable into other laboratories and whether these tissues can be constructed reproducibly. Our results demonstrate the reproducible production of the hemi-cornea model according to standard operation procedures using 15 independent batches of reconstructed hemi-cornea models in two independent laboratories each. Furthermore, the hemi-cornea tissues have been treated with 20 chemicals of different eye-irritating potential under blind conditions to assess the performance and limitations of our test system comparing three different prediction models. The most suitable prediction model revealed an overall in vitro-in vivo concordance of 80% and 70% in the participating laboratories, respectively, and an inter-laboratory concordance of 80%. Sensitivity of the test was 77% and specificity was between 57% and 86% to discriminate classified from non-classified chemicals. We conclude that additional physiologically relevant endpoints in both epithelium and stroma have to be developed for the reliable prediction of all GHS classes of eye irritation in one stand alone test system. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Human regional cerebral blood flow during rapid-eye-movement sleep

    DEFF Research Database (Denmark)

    Madsen, P L; Holm, S; Vorstrup, S

    1991-01-01

    Owing to the coupling between CBF and neuronal activity, regional CBF is a reflection of neural activity in different brain regions. In this study we measured regional CBF during polysomnographically well-defined rapid-eye-movement (REM) sleep by the use of single photon emission computerized...... tomography and the new tracer 99mTc-dl-hexamethylpropyleneamine. Eleven healthy volunteers aged between 22 and 27 years were studied. CBF was measured on separate nights during REM sleep and during EEG-verified wakefulness. On awakening from REM sleep, all subjects reported visual dreams. During REM sleep...... dream experiences. On the other hand, the reduced involvement of the inferior frontal cortex observed during REM sleep might explain the poor temporal organization and bizarreness often experienced in dreams....

  17. A Novel mouse model of enhanced proteostasis: Full-length human heat shock factor 1 transgenic mice

    International Nuclear Information System (INIS)

    Pierce, Anson; Wei, Rochelle; Halade, Dipti; Yoo, Si-Eun; Ran, Qitao; Richardson, Arlan

    2010-01-01

    Research highlights: → Development of mouse overexpressing native human HSF1 in all tissues including CNS. → HSF1 overexpression enhances heat shock response at whole-animal and cellular level. → HSF1 overexpression protects from polyglutamine toxicity and favors aggresomes. → HSF1 overexpression enhances proteostasis at the whole-animal and cellular level. -- Abstract: The heat shock response (HSR) is controlled by the master transcriptional regulator heat shock factor 1 (HSF1). HSF1 maintains proteostasis and resistance to stress through production of heat shock proteins (HSPs). No transgenic model exists that overexpresses HSF1 in tissues of the central nervous system (CNS). We generated a transgenic mouse overexpressing full-length non-mutant HSF1 and observed a 2-4-fold increase in HSF1 mRNA and protein expression in all tissues studied of HSF1 transgenic (HSF1 +/0 ) mice compared to wild type (WT) littermates, including several regions of the CNS. Basal expression of HSP70 and 90 showed only mild tissue-specific changes; however, in response to forced exercise, the skeletal muscle HSR was more elevated in HSF1 +/0 mice compared to WT littermates and in fibroblasts following heat shock, as indicated by levels of inducible HSP70 mRNA and protein. HSF1 +/0 cells elicited a significantly more robust HSR in response to expression of the 82 repeat polyglutamine-YFP fusion construct (Q82YFP) and maintained proteasome-dependent processing of Q82YFP compared to WT fibroblasts. Overexpression of HSF1 was associated with fewer, but larger Q82YFP aggregates resembling aggresomes in HSF1 +/0 cells, and increased viability. Therefore, our data demonstrate that tissues and cells from mice overexpressing full-length non-mutant HSF1 exhibit enhanced proteostasis.

  18. Remifentanil inhibits rapid eye movement sleep but not the nocturnal melatonin surge in humans.

    Science.gov (United States)

    Bonafide, Christopher P; Aucutt-Walter, Natalie; Divittore, Nicole; King, Tonya; Bixler, Edward O; Cronin, Arthur J

    2008-04-01

    Postoperative patients are sleep deprived. Opioids, commonly administered for postoperative pain control, are often mistakenly considered inducers of naturally occurring sleep. This study describes the effect of the opioid remifentanil on nocturnal sleep in healthy volunteers. In addition, this study tests the hypothesis that opioid-induced sleep disturbance is caused by a circadian pacemaker disturbance, reflected by suppressed nocturnal plasma concentration of melatonin. Polysomnography was performed in 10 volunteers from 11:00 pm to 7:00 am for four nights at 6-day intervals. On two nights, remifentanil (0.01-0.04 microg x kg x min) was infused from 10:30 pm to 7:00 am, and either a placebo capsule or 3.0 mg melatonin was administered at 10:30 pm. On two additional nights, saline was infused, and the placebo or melatonin capsules were administered at 10:30 pm. Blood was drawn at 12:00 am, 3:00 am, and 6:00 am to measure the plasma concentration of melatonin and cortisol. A repeated-measures analysis of variance model was used to determine the effect of remifentanil on sleep stages, the effect of remifentanil on the plasma concentration of melatonin, and the effect of exogenous melatonin on remifentanil-induced sleep disturbance. Remifentanil inhibited rapid eye movement sleep (14.1 +/- 7.2% to 3.9 +/- 6.9%). The amount of slow wave sleep decreased from 6.8 +/- 7.6% to 3.2 +/- 6.1%, but this decrease was not statistically significant. Remifentanil did not decrease melatonin concentration. Melatonin administration did not prevent remifentanil-induced sleep disturbance. An overnight constant infusion of remifentanil inhibits rapid eye movement sleep without suppressing the nocturnal melatonin surge.

  19. Direct comparison of flow-FISH and qPCR as diagnostic tests for telomere length measurement in humans.

    Directory of Open Access Journals (Sweden)

    Fernanda Gutierrez-Rodrigues

    Full Text Available Telomere length measurement is an essential test for the diagnosis of telomeropathies, which are caused by excessive telomere erosion. Commonly used methods are terminal restriction fragment (TRF analysis by Southern blot, fluorescence in situ hybridization coupled with flow cytometry (flow-FISH, and quantitative PCR (qPCR. Although these methods have been used in the clinic, they have not been comprehensively compared. Here, we directly compared the performance of flow-FISH and qPCR to measure leukocytes' telomere length of healthy individuals and patients evaluated for telomeropathies, using TRF as standard. TRF and flow-FISH showed good agreement and correlation in the analysis of healthy subjects (R(2 = 0.60; p<0.0001 and patients (R(2 = 0.51; p<0.0001. In contrast, the comparison between TRF and qPCR yielded modest correlation for the analysis of samples of healthy individuals (R(2 = 0.35; p<0.0001 and low correlation for patients (R(2 = 0.20; p = 0.001; Bland-Altman analysis showed poor agreement between the two methods for both patients and controls. Quantitative PCR and flow-FISH modestly correlated in the analysis of healthy individuals (R(2 = 0.33; p<0.0001 and did not correlate in the comparison of patients' samples (R(2 = 0.1, p = 0.08. Intra-assay coefficient of variation (CV was similar for flow-FISH (10.8 ± 7.1% and qPCR (9.5 ± 7.4%; p = 0.35, but the inter-assay CV was lower for flow-FISH (9.6 ± 7.6% vs. 16 ± 19.5%; p = 0.02. Bland-Altman analysis indicated that flow-FISH was more precise and reproducible than qPCR. Flow-FISH and qPCR were sensitive (both 100% and specific (93% and 89%, respectively to distinguish very short telomeres. However, qPCR sensitivity (40% and specificity (63% to detect telomeres below the tenth percentile were lower compared to flow-FISH (80% sensitivity and 85% specificity. In the clinical setting, flow-FISH was more accurate, reproducible, sensitive, and specific in the measurement of human

  20. Numerical model of heat transfer in the human eye with consideration of fluid dynamics of the aqueous humour

    Energy Technology Data Exchange (ETDEWEB)

    Karampatzakis, Andreas; Samaras, Theodoros, E-mail: theosama@auth.g [Department of Physics, Aristotle University of Thessaloniki, GR-54124 Thessaloniki (Greece)

    2010-10-07

    In this work we present a new 3D numerical model for heat transfer in the human eye, which takes into account the aqueous humour flow in the anterior chamber. We show that consideration of this phenomenon in the calculations alters the temperature distribution on the corneal and lens surfaces, without, however, noticeably changing their absolute values. The most notable effect is that the coolest area of the cornea moves at a point of 2 mm inferior to its geometric centre. The maximum velocity of the fluid in the anterior chamber was found to be 3.36 x 10{sup -4} m s{sup -1}. The effect of the flow on displacing the cool area of the corneal surface temperature is counterbalanced by assuming anisotropic thermal conductivity. The model was implemented in the case of an artificial intraocular lens to show the resulting temperature variations.

  1. A teaser made simple: a didactic measurement of the spectral answer of a human-eye-calibrated lux meter

    International Nuclear Information System (INIS)

    Di Capua, R; Offi, F; Dell'Omo, M; Fontana, F

    2012-01-01

    A simple didactic experiment has been designed and realized, in order to illustrate to undergraduate students in scientific faculties some basic concepts lying behind the fundamentals of geometrical optics. The spectral response of a human-eye-calibrated lux meter was measured using a very trivial experimental arrangement. The white light of a halogen lamp was decomposed into its spectral components through a diffraction grating, so that collecting the radiation at different dispersion angles allowed one to measure the intensity as a function of wavelength. The experiment can be used to effectively illustrate the concepts of spectral distribution, the radiometry versus photometry conversion and photopic response, and the famous historical experience by Herschel on the ‘temperature of colours’. (paper)

  2. Numerical model of heat transfer in the human eye with consideration of fluid dynamics of the aqueous humour.

    Science.gov (United States)

    Karampatzakis, Andreas; Samaras, Theodoros

    2010-10-07

    In this work we present a new 3D numerical model for heat transfer in the human eye, which takes into account the aqueous humour flow in the anterior chamber. We show that consideration of this phenomenon in the calculations alters the temperature distribution on the corneal and lens surfaces, without, however, noticeably changing their absolute values. The most notable effect is that the coolest area of the cornea moves at a point of 2 mm inferior to its geometric centre. The maximum velocity of the fluid in the anterior chamber was found to be 3.36 × 10(-4) m s(-1). The effect of the flow on displacing the cool area of the corneal surface temperature is counterbalanced by assuming anisotropic thermal conductivity. The model was implemented in the case of an artificial intraocular lens to show the resulting temperature variations.

  3. Numerical model of heat transfer in the human eye with consideration of fluid dynamics of the aqueous humour

    International Nuclear Information System (INIS)

    Karampatzakis, Andreas; Samaras, Theodoros

    2010-01-01

    In this work we present a new 3D numerical model for heat transfer in the human eye, which takes into account the aqueous humour flow in the anterior chamber. We show that consideration of this phenomenon in the calculations alters the temperature distribution on the corneal and lens surfaces, without, however, noticeably changing their absolute values. The most notable effect is that the coolest area of the cornea moves at a point of 2 mm inferior to its geometric centre. The maximum velocity of the fluid in the anterior chamber was found to be 3.36 x 10 -4 m s -1 . The effect of the flow on displacing the cool area of the corneal surface temperature is counterbalanced by assuming anisotropic thermal conductivity. The model was implemented in the case of an artificial intraocular lens to show the resulting temperature variations.

  4. Through Human Eyes: A New Approach to the Problem of Workforces in Remote Areas.

    Science.gov (United States)

    Simmonds, W. H. C.

    The often unstable workforce in remote areas can possibly be strengthened by stabilizing adjacent human settlements with community design which works from the inside out to emphasize the human, social, cultural, and environmental aspects of the settlements. Because stresses resulting from isolation, loss of social relationships, lack of…

  5. Human Rights and the Ethno-Nationalist Problematic through the Eyes of Greek-Cypriot Teachers

    Science.gov (United States)

    Zembylas, Michalinos; Charalambous, Panayiota; Charalambous, Constadina; Lesta, Stalo

    2016-01-01

    The present article aims to examine the interplay between the transnational discourses of human rights and the particularities of local constructions and conceptualisations of human rights within the context of an ethnically divided society, Cyprus. Specifically, this interplay is examined through a qualitative study of Greek-Cypriot primary…

  6. Analysis of the Viscoelastic Properties of the Human Cornea Using Scheimpflug Imaging in Inflation Experiment of Eye Globes

    Science.gov (United States)

    Lombardo, Giuseppe; Serrao, Sebastiano; Rosati, Marianna; Lombardo, Marco

    2014-01-01

    Purpose To demonstrate a Scheimpflug-based imaging procedure for investigating the depth- and time-dependent strain response of the human cornea to inflation testing of whole eye globes. Methods Six specimens, three of which with intact corneal epithelium, were mounted in a customized apparatus within a humidity and temperature-monitored wet chamber. Each specimen was subjected to two mechanical tests in order to measure corneal strain resulting from application of cyclic (cyclic regimen) and constant (creep regimen) stress by changing the intra-ocular pressure (IOP) within physiological ranges (18–42 mmHg). Corneal shape changes were analyzed as a function of IOP and both corneal stress-strain curves and creep curves were generated. Results The procedure was highly accurate and repeatable. Upon cyclic stress application, a biomechanical corneal elasticity gradient was found in the front-back direction. The average Young's modulus of the anterior cornea ranged between 2.28±0.87 MPa and 3.30±0.90 MPa in specimens with and without intact epithelium (P = 0.05) respectively. The Young's modulus of the posterior cornea was on average 0.21±0.09 MPa and 0.17±0.06 MPa (P>0.05) respectively. The time-dependent strain response of the cornea to creep testing was quantified by fitting data to a modified Zener model for extracting both the relaxation time and compliance function. Conclusion Cyclic and creep mechanical tests are valuable for investigating the strain response of the intact human cornea within physiological IOP ranges, providing meaningful results that can be translated to clinic. The presence of epithelium influences the results of anterior corneal shape changes when monitoring deformation via Scheimpflug imaging in inflation experiments of whole eye globes. PMID:25397674

  7. SU-G-IeP4-09: Method of Human Eye Aberration Measurement Using Plenoptic Camera Over Large Field of View

    Energy Technology Data Exchange (ETDEWEB)

    Lv, Yang; Wang, Ruixing; Ma, Haotong; Zhang, Xuanzhe; Ning, Yu; Xu, Xiaojun [College of Optoelectronic Science and Engineering, National University of Defense Technology, Changsha (China)

    2016-06-15

    Purpose: The measurement based on Shack-Hartmann wave-front sensor(WFS), obtaining both the high and low order wave-front aberrations simultaneously and accurately, has been applied in the detection of human eyes aberration in recent years. However, Its application is limited by the small field of view (FOV), slight eye movement leads the optical bacon image exceeds the lenslet array which result in uncertain detection error. To overcome difficulties of precise eye location, the capacity of detecting eye wave-front aberration over FOV much larger than simply a single conjugate Hartmann WFS accurately and simultaneously is demanded. Methods: Plenoptic camera’s lenslet array subdivides the aperture light-field in spatial frequency domain, capture the 4-D light-field information. Data recorded by plenoptic cameras can be used to extract the wave-front phases associated to the eyes aberration. The corresponding theoretical model and simulation system is built up in this article to discuss wave-front measurement performance when utilizing plenoptic camera as wave-front sensor. Results: The simulation results indicate that the plenoptic wave-front method can obtain both the high and low order eyes wave-front aberration with the same accuracy as conventional system in single visual angle detectionand over FOV much larger than simply a single conjugate Hartmann systems. Meanwhile, simulation results show that detection of eye aberrations wave-front in different visual angle can be achieved effectively and simultaneously by plenoptic method, by both point and extended optical beacon from the eye. Conclusion: Plenoptic wave-front method possesses the feasibility in eye aberrations wave-front detection. With larger FOV, the method can effectively reduce the detection error brought by imprecise eye location and simplify the eye aberrations wave-front detection system comparing with which based on Shack-Hartmann WFS. Unique advantage of the plenoptic method lies in obtaining

  8. SU-G-IeP4-09: Method of Human Eye Aberration Measurement Using Plenoptic Camera Over Large Field of View

    International Nuclear Information System (INIS)

    Lv, Yang; Wang, Ruixing; Ma, Haotong; Zhang, Xuanzhe; Ning, Yu; Xu, Xiaojun

    2016-01-01

    Purpose: The measurement based on Shack-Hartmann wave-front sensor(WFS), obtaining both the high and low order wave-front aberrations simultaneously and accurately, has been applied in the detection of human eyes aberration in recent years. However, Its application is limited by the small field of view (FOV), slight eye movement leads the optical bacon image exceeds the lenslet array which result in uncertain detection error. To overcome difficulties of precise eye location, the capacity of detecting eye wave-front aberration over FOV much larger than simply a single conjugate Hartmann WFS accurately and simultaneously is demanded. Methods: Plenoptic camera’s lenslet array subdivides the aperture light-field in spatial frequency domain, capture the 4-D light-field information. Data recorded by plenoptic cameras can be used to extract the wave-front phases associated to the eyes aberration. The corresponding theoretical model and simulation system is built up in this article to discuss wave-front measurement performance when utilizing plenoptic camera as wave-front sensor. Results: The simulation results indicate that the plenoptic wave-front method can obtain both the high and low order eyes wave-front aberration with the same accuracy as conventional system in single visual angle detectionand over FOV much larger than simply a single conjugate Hartmann systems. Meanwhile, simulation results show that detection of eye aberrations wave-front in different visual angle can be achieved effectively and simultaneously by plenoptic method, by both point and extended optical beacon from the eye. Conclusion: Plenoptic wave-front method possesses the feasibility in eye aberrations wave-front detection. With larger FOV, the method can effectively reduce the detection error brought by imprecise eye location and simplify the eye aberrations wave-front detection system comparing with which based on Shack-Hartmann WFS. Unique advantage of the plenoptic method lies in obtaining

  9. Eye Protection

    OpenAIRE

    Pashby, Tom

    1986-01-01

    Eye injuries frequently occur in the home, at work and at play. Many result in legally blind eyes, and most are preventable. Awareness of potential hazards is essential to preventing eye injuries, particularly in children. In addition, protective devices must be used appropriately. We have developed eye protectors that have proved effective in reducing both the overall incidence and the severity of sports eye injuries.

  10. Pst I restriction fragment length polymorphism of the human placental alkaline phosphatase gene in normal placentae and tumors

    International Nuclear Information System (INIS)

    Tsavaler, L.; Penhallow, R.C.; Kam, W.; Sussman, H.H.

    1987-01-01

    The structure of the human placental alkaline phosphatase gene from normal term placentae was studied by restriction enzyme digestion and Southern blot analysis using a cDNA probe to the gene for the placental enzyme. The DNA digests fall into three distinct patterns based on the presence and intensity of an extra 1.1-kilobase Pst I Band. The extra 1.1-kilobase band is present in 9 of 27 placenta samples, and in 1 of these samples the extra band is present at double intensity. No polymorphism was revealed by digestion with restriction enzymes EcoRI, Sma I, BamHI, or Sac I. The extra Pst I-digestion site may lie in a noncoding region of the gene because no correlation was observed between the restriction fragment length polymorphism and the common placental alkaline phosphatase alleles identified by starch gel electrophoresis. In addition, because placental alkaline phosphatase is frequently re-expressed in neoplasms, the authors examined tissue from ovarian, testicular, and endometrial tumors and from BeWo choriocarcinoma cells in culture. The Pst I-DNA digestion patterns from these cells and tissues were identical to those seen in the normal ovary and term placentae. The consistent reproducible digestion patterns seen in DNA from normal and tumor tissue indicate that a major gene rearrangement is not the basis for the ectopic expression of placental alkaline phosphatase in neoplasia

  11. About the Eye

    Medline Plus

    Full Text Available ... The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips ... addressed to the NEI Website Manager . Department of Health and Human Services | The National Institutes of Health | ...

  12. Prediction of temperature and damage in an irradiated human eye-Utilization of a detailed computer model which includes a vectorial blood stream in the choroid.

    Science.gov (United States)

    Heussner, Nico; Holl, Lukas; Nowak, Timo; Beuth, Thorsten; Spitzer, Martin S; Stork, Wilhelm

    2014-08-01

    The work presented here describes the development and use of a three-dimensional thermo-dynamic model of the human eye for the prediction of temperatures and damage thresholds under irradiation. This model takes into account the blood flow by the implementation of a vectorial blood stream in the choroid and also uses the actual physiological extensions and tissue parameters of the eye. Furthermore it considers evaporation, radiation and convection at the cornea as well as the eye lid. The predicted temperatures were successfully validated against existing eye models in terms of corneal and global thermal behaviour. The model׳s predictions were additionally checked for consistency with in-vivo temperature measurements of the cornea, the irradiated retina and its damage thresholds. These thresholds were calculated from the retinal temperatures using the Arrhenius integral. Hence the model can be used to predict the temperature increase and irradiation hazard within the human eye as long as the absorption values and the Arrhenius coefficients are known and the damage mechanism is in the thermal regime. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Dietary Supplementation with a Combination of Lactoferrin, Fish Oil, and Enterococcus faecium WB2000 for Treating Dry Eye: A Rat Model and Human Clinical Study.

    Science.gov (United States)

    Kawashima, Motoko; Nakamura, Shigeru; Izuta, Yusuke; Inoue, Sachiko; Tsubota, Kazuo

    2016-04-01

    To examine the effect of a combined dietary supplement containing fish oil, lactoferrin, zinc, vitamin C, lutein, vitamin E, γ-aminobutanoic acid, and Enterococcus faecium WB2000 on dry eye. A preliminary study in a rat model and a prospective, randomized, double-blind, placebo-controlled study in humans were conducted. Forty Japanese volunteers aged 22 to 59 years were randomized into combined dietary supplement (2 capsules/day; 20 participants) and placebo (vehicle; 19 participants) groups and treated once daily for 8 weeks. Rats received the combined dietary supplement components (10 or 50 mg/kg orally) or vehicle (2% DMSO), and dry eye was mechanically induced for 2 days. Tear production was measured in rats after dry eye was induced. Humans were assessed at baseline and weeks 4 and 8 post-supplementation based on keratoconjunctival epithelial damage; fluorescein tear film breakup time; tear production; biochemical data; information regarding subjective dry eye symptoms by answering a questionnaire; and information regarding adverse events via medical interviews. Supplementation dose-dependently mitigated the decrease in tear production in rats. Among subjects with confirmed dry eye, clinical symptoms improved at weeks 4 and 8 more significantly in the supplementation group than in the placebo group (Peye symptoms. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Spherical aberration and other higher-order aberrations in the human eye : from summary wave-front analysis data to optical variables relevant to visual perception

    NARCIS (Netherlands)

    Jansonius, Nomdo M.

    Wave-front analysis data from the human eye are commonly presented using the aberration coefficient c(4)(0) (primary spherical aberration) together with an overall measure of all higher-order aberrations. If groups of subjects are compared, however, the relevance of an observed difference cannot

  15. Computing the stresses and deformations of the human eye components due to a high explosive detonation using fluid-structure interaction model.

    Science.gov (United States)

    Karimi, Alireza; Razaghi, Reza; Navidbakhsh, Mahdi; Sera, Toshihiro; Kudo, Susumu

    2016-05-01

    In spite the fact that a very small human body surface area is comprised by the eye, its wounds due to detonation have recently been dramatically amplified. Although many efforts have been devoted to measure injury of the globe, there is still a lack of knowledge on the injury mechanism due to Primary Blast Wave (PBW). The goal of this study was to determine the stresses and deformations of the human eye components, including the cornea, aqueous, iris, ciliary body, lens, vitreous, retina, sclera, optic nerve, and muscles, attributed to PBW induced by trinitrotoluene (TNT) explosion via a Lagrangian-Eulerian computational coupling model. Magnetic Resonance Imaging (MRI) was employed to establish a Finite Element (FE) model of the human eye according to a normal human eye. The solid components of the eye were modelled as Lagrangian mesh, while an explosive TNT, air domain, and aqueous were modelled using Arbitrary Lagrangian-Eulerian (ALE) mesh. Nonlinear dynamic FE simulations were accomplished using the explicit FE code, namely LS-DYNA. In order to simulate the blast wave generation, propagation, and interaction with the eye, the ALE formulation with Jones-Wilkins-Lee (JWL) equation defining the explosive material were employed. The results revealed a peak stress of 135.70kPa brought about by detonation upsurge on the cornea at the distance of 25cm. The highest von Mises stresses were observed on the sclera (267.3kPa), whereas the lowest one was seen on the vitreous body (0.002kPa). The results also showed a relatively high resultant displacement for the macula as well as a high variation for the radius of curvature for the cornea and lens, which can result in both macular holes, optic nerve damage and, consequently, vision loss. These results may have implications not only for understanding the value of stresses and strains in the human eye components but also giving an outlook about the process of PBW triggers damage to the eye. Copyright © 2016 Elsevier Ltd

  16. Immunohistochemical markers for corneal stem cells in the early developing human eye

    DEFF Research Database (Denmark)

    Lyngholm, Mikkel; Høyer, Poul E; Vorum, Henrik

    2008-01-01

    niche (week 14) in human embryos and fetuses. The expression of SOD2 and CK15 was investigated together with other recently identified limbal proteins. Previously suggested LSC and differentiation markers (PAX6, aquaporin-1 and nestin) were also investigated. Both SOD2 and CK15 were present...... markers and potential markers for LSCs and early transient amplifying cells in human adults. In this study, we describe the development of the ectodermally derived LSCs and the mesodermally derived niche cells from the time at which the cornea is defined (week 6) until the formation of the early limbal...

  17. Mapping human resources for eye health in 21 countries of sub-Saharan Africa: current progress towards VISION 2020

    Science.gov (United States)

    2014-01-01

    Background Development of human resources for eye health (HReH) is a major focus of the Global Action Plan 2014 to 2019 to reduce the prevalence of avoidable visual impairment by 25% by the year 2019. The eye health workforce is thought to be much smaller in sub-Saharan Africa than in other regions of the world but data to support this for policy-making is scarce. We collected HReH and cataract surgeries data from 21 countries in sub-Sahara to estimate progress towards key suggested population-based VISION 2020 HReH indicators and cataract surgery rates (CSR) in 2011. Methods Routinely collected data on practitioner and surgery numbers in 2011 was requested from national eye care coordinators via electronic questionnaires. Telephone and e-mail discussions were used to determine data collection strategies that fit the national context and to verify reported data quality. Information was collected on six practitioner cadres: ophthalmologists, cataract surgeons, ophthalmic clinical officers, ophthalmic nurses, optometrists and ‘mid-level refractionists’ and combined with publicly available population data to calculate practitioner to population ratios and CSRs. Associations with development characteristics were conducted using Wilcoxon rank sum tests and Spearman rank correlations. Results HReH data was not easily available. A minority of countries had achieved the suggested VISION 2020 targets in 2011; five countries for ophthalmologists/cataract surgeons, four for ophthalmic nurses/clinical officers and two for CSR. All countries were below target for optometrists, even when other cadres who perform refractions as a primary duty were considered. The regional (sample) ratio for surgeons (ophthalmologists and cataract surgeons) was 2.9 per million population, 5.5 for ophthalmic clinical officers and nurses, 3.7 for optometrists and other refractionists, and 515 for CSR. A positive correlation between GDP and CSR as well as many practitioner ratios was observed

  18. Mapping human resources for eye health in 21 countries of sub-Saharan Africa: current progress towards VISION 2020.

    Science.gov (United States)

    Palmer, Jennifer J; Chinanayi, Farai; Gilbert, Alice; Pillay, Devan; Fox, Samantha; Jaggernath, Jyoti; Naidoo, Kovin; Graham, Ronnie; Patel, Daksha; Blanchet, Karl

    2014-08-15

    Development of human resources for eye health (HReH) is a major focus of the Global Action Plan 2014 to 2019 to reduce the prevalence of avoidable visual impairment by 25% by the year 2019. The eye health workforce is thought to be much smaller in sub-Saharan Africa than in other regions of the world but data to support this for policy-making is scarce. We collected HReH and cataract surgeries data from 21 countries in sub-Sahara to estimate progress towards key suggested population-based VISION 2020 HReH indicators and cataract surgery rates (CSR) in 2011. Routinely collected data on practitioner and surgery numbers in 2011 was requested from national eye care coordinators via electronic questionnaires. Telephone and e-mail discussions were used to determine data collection strategies that fit the national context and to verify reported data quality. Information was collected on six practitioner cadres: ophthalmologists, cataract surgeons, ophthalmic clinical officers, ophthalmic nurses, optometrists and 'mid-level refractionists' and combined with publicly available population data to calculate practitioner to population ratios and CSRs. Associations with development characteristics were conducted using Wilcoxon rank sum tests and Spearman rank correlations. HReH data was not easily available. A minority of countries had achieved the suggested VISION 2020 targets in 2011; five countries for ophthalmologists/cataract surgeons, four for ophthalmic nurses/clinical officers and two for CSR. All countries were below target for optometrists, even when other cadres who perform refractions as a primary duty were considered. The regional (sample) ratio for surgeons (ophthalmologists and cataract surgeons) was 2.9 per million population, 5.5 for ophthalmic clinical officers and nurses, 3.7 for optometrists and other refractionists, and 515 for CSR. A positive correlation between GDP and CSR as well as many practitioner ratios was observed (CSR P = 0

  19. LIMNOLOGICAL OPTOMETRY: EXAMINING EARTH'S EYE

    Science.gov (United States)

    In Thoreau's Walden, a lake is described as the landscape's most expressive feature and the earth's eye. Collectively, scientists are charged by society to assess, monitor, and remedy maladies of earth's eye in the same way optometrists maintain the health of the human eye. This ...

  20. Radiocarbon dating of the human eye lens crystallines reveal proteins without carbon turnover throughout life

    DEFF Research Database (Denmark)

    Lynnerup, Niels; Kjeldsen, Henrik; Heegaard, Steffen

    2008-01-01

    , there is no subsequent remodelling of these fibers, nor removal of degraded lens fibers. Human tissue ultimately derives its (14)C content from the atmospheric carbon dioxide. The (14)C content of the lens proteins thus reflects the atmospheric content of (14)C when the lens crystallines were formed. Precise radiocarbon...

  1. Collagen VII deficient mice show morphologic and histologic corneal changes that phenotypically mimic human dystrophic epidermolysis bullosa of the eye.

    Science.gov (United States)

    Chen, Vicki M; Shelke, Rajani; Nyström, Alexander; Laver, Nora; Sampson, James F; Zhiyi, Cao; Bhat, Najma; Panjwani, Noorjahan

    2018-06-16

    Absence of collagen VII causes blistering of the skin, eyes and many other tissues. This disease is termed dystrophic epidermolysis bullosa (DEB). Corneal fibrosis occurs in up to 41% and vision loss in up to 64% of patients. Standard treatments are supportive and there is no cure. The immune-histologic and morphologic changes in the corneas of the mouse model for this disease have not been described in the literature. Our purpose is to characterize the eyes of these mice to determine if this is an appropriate model for study of human therapeutics. Western blot analysis (WB) and immunohistochemistry (IHC) were performed to assess the relative collagen VII protein levels and its location within the cornea. Additional IHC for inflammatory and fibrotic biomarkers alpha-smooth muscle actin (α-SMA), transforming growth factor-beta (TGF-β), connective tissue growth factor (CTGF), proteinase 3, tenascin C and collagen III were performed. Clinical photographs documenting opacification of the corneas of animals of differing ages were assessed and scored independently by 2 examiners. Histology was then used to investigate morphologic changes. IHC and WB confirmed that these mice are deficient in collagen VII production at the level of the basement membrane when compared with wild-types. IHC showed anomalous deposition of collagen III throughout the stroma. Of the 5 biomarkers tested, TGF-β showed the strongest and most consistently staining. Photographs documented corneal opacities only in mice older than 10 weeks, opacities were not seen in younger animals. Histology showed multiple abnormalities, including epithelial hyperplasia, ulceration, fibrosis, edema, dysplasia, neovascularization and bullae formation. The collagen VII hypomorphic mouse shows reduced collagen VII production at the level of the corneal basement membrane. Corneal changes are similar to pathology seen in humans with this disease. The presence of anomalous stromal collagen III and TGF-β appear to be

  2. Effects of Long-Term Exposure to 60 GHz Millimeter-Wavelength Radiation on the Genotoxicity and Heat Shock Protein (Hsp Expression of Cells Derived from Human Eye

    Directory of Open Access Journals (Sweden)

    Shin Koyama

    2016-08-01

    Full Text Available Human corneal epithelial (HCE-T and human lens epithelial (SRA01/04 cells derived from the human eye were exposed to 60 gigahertz (GHz millimeter-wavelength radiation for 24 h. There was no statistically significant increase in the micronucleus (MN frequency in cells exposed to 60 GHz millimeter-wavelength radiation at 1 mW/cm2 compared with sham-exposed controls and incubator controls. The MN frequency of cells treated with bleomycin for 1 h provided positive controls. The comet assay, used to detect DNA strand breaks, and heat shock protein (Hsp expression also showed no statistically significant effects of exposure. These results indicate that exposure to millimeter-wavelength radiation has no effect on genotoxicity in human eye cells.

  3. Manipulation of pre-target activity on the right frontal eye field enhances conscious visual perception in humans.

    Directory of Open Access Journals (Sweden)

    Lorena Chanes

    Full Text Available The right Frontal Eye Field (FEF is a region of the human brain, which has been consistently involved in visuo-spatial attention and access to consciousness. Nonetheless, the extent of this cortical site's ability to influence specific aspects of visual performance remains debated. We hereby manipulated pre-target activity on the right FEF and explored its influence on the detection and categorization of low-contrast near-threshold visual stimuli. Our data show that pre-target frontal neurostimulation has the potential when used alone to induce enhancements of conscious visual detection. More interestingly, when FEF stimulation was combined with visuo-spatial cues, improvements remained present only for trials in which the cue correctly predicted the location of the subsequent target. Our data provide evidence for the causal role of the right FEF pre-target activity in the modulation of human conscious vision and reveal the dependence of such neurostimulatory effects on the state of activity set up by cue validity in the dorsal attentional orienting network.

  4. A simple strategy for the purification of native recombinant full-length human RPL10 protein from inclusion bodies.

    Science.gov (United States)

    Pereira, Larissa M; Silva, Luana R; Alves, Joseane F; Marin, Nélida; Silva, Flavio Sousa; Morganti, Ligia; Silva, Ismael D C G; Affonso, Regina

    2014-09-01

    The L10 ribosomal protein (RPL10) plays a role in the binding of the 60 S and 40 S ribosomal subunits and in mRNA translation. The evidence indicates that RPL10 also has multiple extra-ribosomal functions, including tumor suppression. Recently, the presence of RPL10 in prostate and ovarian cancers was evaluated, and it was demonstrated to be associated with autistic disorders and premature ovarian failure. In the present work, we successfully cloned and expressed full-length human RPL10 (hRPL10) protein and isolated inclusion bodies containing this protein that had formed under mild growth conditions. The culture produced 376mg of hRPL10 protein per liter of induced bacterial culture, of which 102.4mg was present in the soluble fraction, and 25.6mg was recovered at approximately 94% purity. These results were obtained using a two-step process of non-denaturing protein extraction from pelleted inclusion bodies. We studied the characteristics of this protein using circular dichroism spectroscopy and by monitoring the changes induced by the presence or absence of zinc ions using fluorescence spectrometry. The results demonstrated that the protein obtained using these non-conventional methods retained its secondary and tertiary structure. The conformational changes induced by the incorporation of zinc suggested that this protein could interact with Jun or the SH3 domain of c-yes. The results suggested that the strategy used to obtain hRPL10 is simple and could be applied to obtaining other proteins that are susceptible to degradation. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Age-related changes in the plasticity and toughness of human cortical bone at multiple length-scales

    Energy Technology Data Exchange (ETDEWEB)

    Zimmermann, Elizabeth A.; Schaible, Eric; Bale, Hrishikesh; Barth, Holly D.; Tang, Simon Y.; Reichert, Peter; Busse, Bjoern; Alliston, Tamara; Ager III, Joel W.; Ritchie, Robert O.

    2011-08-10

    The structure of human cortical bone evolves over multiple length-scales from its basic constituents of collagen and hydroxyapatite at the nanoscale to osteonal structures at nearmillimeter dimensions, which all provide the basis for its mechanical properties. To resist fracture, bone’s toughness is derived intrinsically through plasticity (e.g., fibrillar sliding) at structural-scales typically below a micron and extrinsically (i.e., during crack growth) through mechanisms (e.g., crack deflection/bridging) generated at larger structural-scales. Biological factors such as aging lead to a markedly increased fracture risk, which is often associated with an age-related loss in bone mass (bone quantity). However, we find that age-related structural changes can significantly degrade the fracture resistance (bone quality) over multiple lengthscales. Using in situ small-/wide-angle x-ray scattering/diffraction to characterize sub-micron structural changes and synchrotron x-ray computed tomography and in situ fracture-toughness measurements in the scanning electron microscope to characterize effects at micron-scales, we show how these age-related structural changes at differing size-scales degrade both the intrinsic and extrinsic toughness of bone. Specifically, we attribute the loss in toughness to increased non-enzymatic collagen cross-linking which suppresses plasticity at nanoscale dimensions and to an increased osteonal density which limits the potency of crack-bridging mechanisms at micron-scales. The link between these processes is that the increased stiffness of the cross-linked collagen requires energy to be absorbed by “plastic” deformation at higher structural levels, which occurs by the process of microcracking.

  6. Timing of blunt force injuries in long bones: the effects of the environment, PMI length and human surrogate model.

    Science.gov (United States)

    Coelho, Luís; Cardoso, Hugo F V

    2013-12-10

    Timing of blunt force trauma in human bone is a critical forensic issue, but there is limited knowledge on how different environmental conditions, the duration of postmortem interval (PMI), different bone types and different animal models influence fracture morphology. This study aims at evaluating the influence of the type of postmortem environment and the duration of the postmortem period on fracture morphology, for distinguishing perimortem from postmortem fractures on different types of long bones from different species. Fresh limb segments from pig and goat were sequentially left to decompose, under 3 different environmental circumstances (surface, buried and submerged), resulting in sets with different PMI lengths (0, 28, 56, 84, 112, 140, 168 and 196 days), which were then fractured. Fractured bones (total=325; pig tibia=110; pig fibula=110; goat metatarsals=105) were classified according to the Fracture Freshness Index (FFI). Climatic data for the experiment location was collected. Statistical analysis included descriptive statistics, correlation analysis between FFI and PMI, Mann-Whitney U tests comparing FFI medians for different PMI's and linear regression analysis using PMI, pluviosity and temperature as predictors for FFI. Surface samples presented increases in FFI with increasing PMI, with positive correlations for all bone types. The same results were observed in submerged samples, except for pig tibia. Median FFI values for surface samples could distinguish bones with PMI=0 days from PMI≥56 days. Buried samples presented no significant correlation between FFI and PMI, and nonsignificant regression models. Regression analysis of surface and submerged samples suggested differences in FFI variation with PMI between bone types, although without statistical significance. Adding climatic data to surface regression models resulted in PMI no longer predicting FFI. When comparing different animal models, linear regressions suggested greater increases in

  7. Space representation for eye movements is more contralateral in monkeys than in humans

    OpenAIRE

    Kagan, Igor; Iyer, Asha; Lindner, Axel; Andersen, Richard A.

    2010-01-01

    Contralateral hemispheric representation of sensory inputs (the right visual hemifield in the left hemisphere and vice versa) is a fundamental feature of primate sensorimotor organization, in particular the visuomotor system. However, many higher-order cognitive functions in humans show an asymmetric hemispheric lateralization—e.g., right brain specialization for spatial processing—necessitating a convergence of information from both hemifields. Electrophysiological studies in monkeys and fun...

  8. [Autoshaping of a button-push response and eye movement in human subjects].

    Science.gov (United States)

    Kimura, H; Fukui, I; Inaki, K

    1990-12-01

    Two experiments were conducted with human subjects to investigate the similarities and differences between animal and human behaviors under autoshaping procedures. In these experiments, light served as CS, and display on TV served as US. Whether the pushing button response or gazing response to CS could be obtained in human subjects under Pavlovian conditioning procedure was examined. In Experiment 1, uninstructed naive subjects were placed in a room containing a push-button and a TV display. Within the experimental sessions, the push-button was lit for 8 s as CS, and then paired with the display of a soft pornographic program on TV for 10 s. The result indicated that the modeling of pushing button promoted the increase of response probability among the subjects. The trials conducted after the rest period indicated an increase of response probability. In Experiment 2, a 4 cm square translucent panel was lit for 20 s as CS, and then paired with the display of a computer graphic picture on TV for 8 s as US. Some subjects started gazing at the CS for several seconds. These results indicated that some subjects could acquire the gazing response under the autoshaping procedure.

  9. Perceiving polarization with the naked eye: characterization of human polarization sensitivity

    Science.gov (United States)

    Temple, Shelby E.; McGregor, Juliette E.; Miles, Camilla; Graham, Laura; Miller, Josie; Buck, Jordan; Scott-Samuel, Nicholas E.; Roberts, Nicholas W.

    2015-01-01

    Like many animals, humans are sensitive to the polarization of light. We can detect the angle of polarization using an entoptic phenomenon called Haidinger's brushes, which is mediated by dichroic carotenoids in the macula lutea. While previous studies have characterized the spectral sensitivity of Haidinger's brushes, other aspects remain unexplored. We developed a novel methodology for presenting gratings in polarization-only contrast at varying degrees of polarization in order to measure the lower limits of human polarized light detection. Participants were, on average, able to perform the task down to a threshold of 56%, with some able to go as low as 23%. This makes humans the most sensitive vertebrate tested to date. Additionally, we quantified a nonlinear relationship between presented and perceived polarization angle when an observer is presented with a rotatable polarized light field. This result confirms a previous theoretical prediction of how uniaxial corneal birefringence impacts the perception of Haidinger's brushes. The rotational dynamics of Haidinger's brushes were then used to calculate corneal retardance. We suggest that psychophysical experiments, based upon the perception of polarized light, are amenable to the production of affordable technologies for self-assessment and longitudinal monitoring of visual dysfunctions such as age-related macular degeneration. PMID:26136441

  10. Zebra Stripes through the Eyes of Their Predators, Zebras, and Humans.

    Directory of Open Access Journals (Sweden)

    Amanda D Melin

    Full Text Available The century-old idea that stripes make zebras cryptic to large carnivores has never been examined systematically. We evaluated this hypothesis by passing digital images of zebras through species-specific spatial and colour filters to simulate their appearance for the visual systems of zebras' primary predators and zebras themselves. We also measured stripe widths and luminance contrast to estimate the maximum distances from which lions, spotted hyaenas, and zebras can resolve stripes. We found that beyond ca. 50 m (daylight and 30 m (twilight zebra stripes are difficult for the estimated visual systems of large carnivores to resolve, but not humans. On moonless nights, stripes are difficult for all species to resolve beyond ca. 9 m. In open treeless habitats where zebras spend most time, zebras are as clearly identified by the lion visual system as are similar-sized ungulates, suggesting that stripes cannot confer crypsis by disrupting the zebra's outline. Stripes confer a minor advantage over solid pelage in masking body shape in woodlands, but the effect is stronger for humans than for predators. Zebras appear to be less able than humans to resolve stripes although they are better than their chief predators. In conclusion, compared to the uniform pelage of other sympatric herbivores it appears highly unlikely that stripes are a form of anti-predator camouflage.

  11. Eye Tracking Metrics for Workload Estimation in Flight Deck Operation

    Science.gov (United States)

    Ellis, Kyle; Schnell, Thomas

    2010-01-01

    Flight decks of the future are being enhanced through improved avionics that adapt to both aircraft and operator state. Eye tracking allows for non-invasive analysis of pilot eye movements, from which a set of metrics can be derived to effectively and reliably characterize workload. This research identifies eye tracking metrics that correlate to aircraft automation conditions, and identifies the correlation of pilot workload to the same automation conditions. Saccade length was used as an indirect index of pilot workload: Pilots in the fully automated condition were observed to have on average, larger saccadic movements in contrast to the guidance and manual flight conditions. The data set itself also provides a general model of human eye movement behavior and so ostensibly visual attention distribution in the cockpit for approach to land tasks with various levels of automation, by means of the same metrics used for workload algorithm development.

  12. Eye Cancer

    Science.gov (United States)

    Cancer of the eye is uncommon. It can affect the outer parts of the eye, such as the eyelid, which are made up ... and nerves. If the cancer starts inside the eyeball it's called intraocular cancer. The most common intraocular ...

  13. Black Eye

    Science.gov (United States)

    ... Your Eyes Sep 20, 2017 Eye Injuries from Laundry Packets On the Rise Jun 30, 2017 ... Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  14. Eye Anatomy

    Science.gov (United States)

    ... News About Us Donate In This Section Eye Anatomy en Español email Send this article to a ... You at Risk For Glaucoma? Childhood Glaucoma Eye Anatomy Five Common Glaucoma Tests Glaucoma Facts and Stats ...

  15. Eye Emergencies

    Science.gov (United States)

    ... The Marfan Foundation Marfan & Related Disorders What is Marfan Syndrome? What are Related Disorders? What are the Signs? ... Emergencies Eye Emergencies Lung Emergencies Surgeries Eye Emergencies Marfan syndrome significantly increases your risk of retinal detachment, a ...

  16. Characterization of microbial communities found in the human vagina by analysis of terminal restriction fragment length polymorphisms of 16S rRNA genes

    NARCIS (Netherlands)

    Coolen, MJL; Post, E; Davis, CC; Forney, LJ

    2005-01-01

    To define and monitor the structure of microbial communities found in the human vagina, a cultivation-independent approach based on analyses of terminal restriction fragment length polymorphisms (T-RFLP) of 16S rRNA genes was developed and validated. Sixteen bacterial strains commonly found in the

  17. Genotyping of human and porcine Yersinia enterocolitica, Yersinia intertmedia, and Yersinia bercovieri strains from Switzerland by amplified fragment length polymorphism analysis

    DEFF Research Database (Denmark)

    Kuehni-Boghenbor, Kathrin; On, Stephen L.W.; Kokotovic, Branko

    2006-01-01

    In this study, 231 strains of Yersinia enterocolitica, 25 strains of Y. intermedia, and 10 strains of Y. bercovieri from human and porcine sources (including reference strains) were analyzed using amplified fragment length polymorphism (AFLP), a whole-genome fingerprinting method for subtyping...

  18. THE HUMAN FUMARYLACETOACETATE GENE : CHARACTERIZATION OF RESTRICTION-FRAGMENT-LENGTH-POLYMORPHISMS AND IDENTIFICATION OF HAPLOTYPES IN TYROSINEMIA TYPE-1 AND PSEUDODEFICIENCY

    NARCIS (Netherlands)

    ROOTWELT, H; KVITTINGEN, EA; HOIE, K; AGSTERIBBE, E; HARTOG, M; BERGER, R

    Deficiency of human fumarylacetoacetase (FAH) activity results in hereditary tyrosinemia type I. Using the restriction enzymes BglII, KpnI and StuI and a 1.3-kb cDNA probe for the FAH gene, we have found 6 restriction fragment length polymorphisms (RFLPs). These RFLPs were utilised in 3 tyrosinemia

  19. Effects of G-CSF on telomere lengths in PBMCs from human immunodeficiency virus-infected patients

    DEFF Research Database (Denmark)

    Aladdin, H; Ullum, H; Schjerling, P

    2000-01-01

    , and not in CD4+ T cells. In this double-blind placebo-controlled study, we investigated the effect of granulocyte colony stimulating factor (G-CSF) treatment combined with highly active antiretroviral therapy (HAART) on mean telomere length in peripheral blood mononuclear cells (PBMC). The terminal restriction...... fragment (TRF) length showed no changes during G-CSF treatment although the number of lymphocytes increased significantly. The mean TRF length correlated positively (R = 0.552, P = 0.009) and negatively (R = -0.503, P = 0.02) to the proportion of CD4+ memory and naïve cells, respectively. Our data suggest...

  20. Fundamental length and relativistic length

    International Nuclear Information System (INIS)

    Strel'tsov, V.N.

    1988-01-01

    It si noted that the introduction of fundamental length contradicts the conventional representations concerning the contraction of the longitudinal size of fast-moving objects. The use of the concept of relativistic length and the following ''elongation formula'' permits one to solve this problem

  1. A General Education Course in Cultural Astronomy: Exploring the Universe Through Human Eyes

    Science.gov (United States)

    Larsen, Kristine

    2017-01-01

    Astronomy courses for non-science majors (often referred to as Astro 101) are the bread and butter of the general education service obligation of astronomy faculty and programs across the US. Their content has traditionally been a general survey of the solar system, stars and galaxies, or even the entire universe. However, because the audience is students who will not be continuing on in astronomy, there is actually no need to cover a broad range of specific topics. Rather, it is more important to concentrate on the scientific process, and hopefully leave the student with an understanding of the relevance of science in everyday life, regardless of his or her major. As a result, some faculty prefer a more interdisciplinary focus for their Astro 101 classes, for example courses on the search for extraterrestrial life. Another option for general education astronomy courses is what has become known as cultural astronomy. Cultural astronomy focuses on the ways in which astronomical knowledge and belief influences human behavior and social structures. Under this umbrella fall two important areas of study, archaeoastronomy (concentrating on ancient cultures) and enthoastronomy (focusing on extant cultures). Such interdisciplinary courses draw heavily upon archaeology, history, anthropology, art, and other fields more traditionally aligned with the humanities and social sciences than the natural sciences, and therefore can be attractive to students in these non-science majors. In such courses, students experience the “humanity” of science: the important connections between science and the human experience, and how experts in myriad fields contribute in meaningful ways to our understanding of how astronomical knowledge has been constructed and disseminated across time and space. This poster describes the content and pedagogy of a general education course in cultural astronomy for non-science majors that stresses hands-on and experiential learning, including the use of

  2. Pharmacological activities of an eye drop containing Matricaria chamomilla and Euphrasia officinalis extracts in UVB-induced oxidative stress and inflammation of human corneal cells.

    Science.gov (United States)

    Bigagli, Elisabetta; Cinci, Lorenzo; D'Ambrosio, Mario; Luceri, Cristina

    2017-08-01

    Ultraviolet B (UVB) exposure is a risk factor for corneal damage resulting in oxidative stress, inflammation and cell death. The aim of this study was to investigate the potential protective effects of a commercial eye drop (Dacriovis™) containing Matricaria chamomilla and Euphrasia officinalis extracts on human corneal epithelial cells (HCEC-12) against UVB radiation-induced oxidative stress and inflammation as well as the underlying mechanisms. The antioxidant potential of the eye drops was evaluated by measuring the ferric reducing antioxidant power and the total phenolic content by Folin-Ciocalteu reagent. HCEC-12 cells were exposed to UVB radiation and treated with the eye drops at various concentrations. Cell viability, wound healing assay, reactive oxygen species (ROS) levels, protein and lipid oxidative damage and COX-2, IL-1β, iNOS, SOD-2, HO-1 and GSS gene expression, were assessed. Eye drops were able to protect corneal epithelial cells from UVB-induced cell death and ameliorated the wound healing; the eye drops exhibited a strong antioxidant activity, decreasing ROS levels and protein and lipid oxidative damage. Eye drops also exerted anti-inflammatory activities by decreasing COX-2, IL-1β, iNOS expression, counteracted UVB-induced GSS and SOD-2 expression and restored HO-1 expression to control levels. These findings suggest that an eye drop containing Matricaria chamomilla and Euphrasia officinalis extracts exerts positive effects against UVB induced oxidative stress and inflammation and may be useful in protecting corneal epithelial cells from UVB exposure. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Analysis of the effects of non-supine sleeping positions on the stress, strain, deformation and intraocular pressure of the human eye

    Science.gov (United States)

    Volpe, Peter A.

    This thesis presents analytical models, finite element models and experimental data to investigate the response of the human eye to loads that can be experienced when in a non-supine sleeping position. The hypothesis being investigated is that non-supine sleeping positions can lead to stress, strain and deformation of the eye as well as changes in intraocular pressure (IOP) that may exacerbate vision loss in individuals who have glaucoma. To investigate the quasi-static changes in stress and internal pressure, a Fluid-Structure Interaction simulation was performed on an axisymmetrical model of an eye. Common Aerospace Engineering methods for analyzing pressure vessels and hyperelastic structural walls are applied to developing a suitable model. The quasi-static pressure increase was used in an iterative code to analyze changes in IOP over time.

  4. Your Eyes

    Science.gov (United States)

    ... away? If you guessed the eye, you're right! Your eyes are at work from the moment you wake up to the ... the eye is seeing. A Muscle Makes It Work The lens is suspended in ... of the lens. That's right — the lens actually changes shape right inside your ...

  5. Is length an appropriate estimator to characterize pulmonary alveolar capillaries? A critical evaluation in the human lung

    DEFF Research Database (Denmark)

    Mühlfeld, Christian; Weibel, Ewald R.; Hahn, Ute

    2010-01-01

    Stereological estimations of total capillary length have been used to characterize changes in the alveolar capillary network (ACN) during developmental processes or pathophysiological conditions. Here, we analyzed whether length estimations are appropriate to describe the 3D nature of the ACN. Semi...... resulted in a mean of 2,746 km (SD: 722 km). Because of the geometry of the ACN both approaches carry an unpredictable bias. The bias incurred by the design-based approach is proportional to the ratio between radius and length of the capillary segments in the ACN, the number of branching points...... and the winding of the capillaries. The model-based approach is biased because of the real noncylindrical shape of capillaries and the network structure. In conclusion, the estimation of the total length of capillaries in the ACN cannot be recommended as the geometry of the ACN does not fulfill the requirements...

  6. Flame Length

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — Flame length was modeled using FlamMap, an interagency fire behavior mapping and analysis program that computes potential fire behavior characteristics. The tool...

  7. Successful transplantation of in vitro expanded human cadaver corneal endothelial precursor cells on to a cadaver bovine's eye using a nanocomposite gel sheet.

    Science.gov (United States)

    Parikumar, Periyasamy; Haraguchi, Kazutoshi; Ohbayashi, Akira; Senthilkumar, Rajappa; Abraham, Samuel J K

    2014-05-01

    In vitro expansion of human corneal endothelial precursor (HCEP) cells has been reported via production of cell aggregated spheres. However, to translate this procedure in human patients warrants maintaining the position of the eyeballs facing down for 36 h, which is not feasible. In this study, we report a method using a nanocomposite (NC) gel sheet to accomplish the integration of HCEP cells to the endothelium of cadaver bovine's eyes. HCEP cells were isolated from the corneal endothelium of a cadaver human eye and then expanded using a thermoreversible gelation polymer (TGP) as reported earlier. For the study, three cadaver bovine eyes were used. The NC gel sheets were inserted into the bovine eyes', aligned and suture-fixed in position under the host endothelium. HCEP cells previously expanded in the TGP were harvested and injected using a 26-gauge syringe between the endothelium and the NC gel sheet. The eyes were left undisturbed for three hours following which the NC gel sheets were gently removed. The corneas were harvested and subjected to histopathological studies. Histopathological studies showed that all the three corneas used for NC gel sheet implantation showed the presence of engrafted HCEP cells, seen as multi-layered cells over the native endothelium of the bovine cornea. Examination of the NC gel sheets used for implantation showed that only very few corneal endothelial cells remained on the sheets amounting to what could be considered negligible. The use of the NC gel sheet makes HCEP cell transplantation feasible for human patients. Further in vitro basic studies followed by translational studies are necessary to bring this method for clinical application in appropriate indications.

  8. "Omics" in Human Colostrum and Mature Milk: Looking to Old Data with New Eyes.

    Science.gov (United States)

    Bardanzellu, Flaminia; Fanos, Vassilios; Reali, Alessandra

    2017-08-07

    Human Milk (HM) is the best source for newborn nutrition until at least six months; it exerts anti-inflammatory and anti-infective functions, promotes immune system formation and supports organ development. Breastfeeding could also protect from obesity, diabetes and cardiovascular disease. Furthermore, human colostrum (HC) presents a peculiar role in newborn support as a protective effect against allergic and chronic diseases, in addition to long-term metabolic benefits. In this review, we discuss the recent literature regarding "omics" technologies and growth factors (GF) in HC and the effects of pasteurization on its composition. Our aim was to provide new evidence in terms of transcriptomics, proteomics, metabolomics, and microbiomics, also in relation to maternal metabolic diseases and/or fetal anomalies and to underline the functions of GF. Since HC results are so precious, particularly for the vulnerable pre-terms category, we also discuss the importance of HM pasteurization to ensure donated HC even to neonates whose mothers are unable to provide. To the best of our knowledge, this is the first review analyzing in detail the molecular pattern, microbiota, bioactive factors, and dynamic profile of HC, finding clinical correlations of such mediators with their possible in vivo effects and with the consequent impact on neonatal outcomes.

  9. Telomere length analysis.

    Science.gov (United States)

    Canela, Andrés; Klatt, Peter; Blasco, María A

    2007-01-01

    Most somatic cells of long-lived species undergo telomere shortening throughout life. Critically short telomeres trigger loss of cell viability in tissues, which has been related to alteration of tissue function and loss of regenerative capabilities in aging and aging-related diseases. Hence, telomere length is an important biomarker for aging and can be used in the prognosis of aging diseases. These facts highlight the importance of developing methods for telomere length determination that can be employed to evaluate telomere length during the human aging process. Telomere length quantification methods have improved greatly in accuracy and sensitivity since the development of the conventional telomeric Southern blot. Here, we describe the different methodologies recently developed for telomere length quantification, as well as their potential applications for human aging studies.

  10. Application of neutron activation analysis to biological materials. Pt. 4. Approach to simultaneous determination of trace elements in human eye tissues with non-destructive neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, T; Bando, M; Nakajima, A [Juntendo Univ., Tokyo (Japan). School of Medicine; Terai, M [Tokyo Metropolitan Univ. (Japan). Faculty of Science; Suzuki-Yasumoto, M [National Inst. of Radiological Sciences, Chiba (Japan)

    1980-01-01

    Fourteen trace elements (short-lived nuclides: Al, Br, Cu, Mn and V; long-lived nuclides: Ag, Au, Cd, Co, Cr, Fe, Sc, Se and Zn) in human eye tissues are determined simultaneously by non-destructive neutron activation analysis. The quantity of Al, Br, Fe, Se and Zn in the eye tissues (about 1 to more than 10 ..mu..g/g dry weight tissue) seems to be higher than that of other trace elements, although the content of each trace element in individual tissue is scattered in a wide range. Conjunctiva, iris (+ciliary body) and choroid (+pigment epithelium) seem to contain larger amount of various trace elements than other eye tissues. From correlation studies it is evident that the relative distribution of 14 trace elements in various eye tissues are similar, and furthermore the content of trace elements in the eye tissues may be correlated in each of the three groups (group A: Cd, Se and Zn; group B: Al, Cr, Fe, Se and V; group C: Al, Au, Fe and Se).

  11. Studies of nontarget-mediated distribution of human full-length IgG1 antibody and its FAb fragment in cardiovascular and metabolic-related tissues.

    Science.gov (United States)

    Davidsson, Pia; Söderling, Ann-Sofi; Svensson, Lena; Ahnmark, Andrea; Flodin, Christine; Wanag, Ewa; Screpanti-Sundqvist, Valentina; Gennemark, Peter

    2015-05-01

    Tissue distribution and pharmacokinetics (PK) of full-length nontargeted antibody and its antigen-binding fragment (FAb) were evaluated for a range of tissues primarily of interest for cardiovascular and metabolic diseases. Mice were intravenously injected with a dose of 10 mg/kg of either human IgG1or its FAb fragment; perfused tissues were collected at a range of time points over 3 weeks for the human IgG1 antibody and 1 week for the human FAb antibody. Tissues were homogenized and antibody concentrations were measured by specific immunoassays on the Gyros system. Exposure in terms of maximum concentration (Cmax ) and area under the curve was assessed for all nine tissues. Tissue exposure of full-length antibody relative to plasma exposure was found to be between 1% and 10%, except for brain (0.2%). Relative concentrations of FAb antibody were the same, except for kidney tissue, where the antibody concentration was found to be ten times higher than in plasma. However, the absolute tissue uptake of full-length IgG was significantly higher than the absolute tissue uptake of the FAb antibody. This study provides a reference PK state for full-length whole and FAb antibodies in tissues related to cardiovascular and metabolic diseases that do not include antigen or antibody binding. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.

  12. Genetic characterization of human herpesvirus type 1: Full-length genome sequence of strain obtained from an encephalitis case from India

    Directory of Open Access Journals (Sweden)

    Vijay P Bondre

    2016-01-01

    Interpretation & conclusions: Our results showed that the full-length genome sequence generated from an Indian HSV-1 isolate shared close genetic relationship with the American KOS and Chinese CR38 strains which belonged to the Asian genetic lineage. Recombination analysis of Indian isolate demonstrated multiple recombination crossover points throughout the genome. This full-length genome sequence amplified from the Indian isolate would be helpful to study HSV evolution, genetic basis of differential pathogenesis, host-virus interactions and viral factors contributing towards differential clinical outcome in human infections.

  13. DeepFix: A Fully Convolutional Neural Network for Predicting Human Eye Fixations.

    Science.gov (United States)

    Kruthiventi, Srinivas S S; Ayush, Kumar; Babu, R Venkatesh

    2017-09-01

    Understanding and predicting the human visual attention mechanism is an active area of research in the fields of neuroscience and computer vision. In this paper, we propose DeepFix, a fully convolutional neural network, which models the bottom-up mechanism of visual attention via saliency prediction. Unlike classical works, which characterize the saliency map using various hand-crafted features, our model automatically learns features in a hierarchical fashion and predicts the saliency map in an end-to-end manner. DeepFix is designed to capture semantics at multiple scales while taking global context into account, by using network layers with very large receptive fields. Generally, fully convolutional nets are spatially invariant-this prevents them from modeling location-dependent patterns (e.g., centre-bias). Our network handles this by incorporating a novel location-biased convolutional layer. We evaluate our model on multiple challenging saliency data sets and show that it achieves the state-of-the-art results.

  14. Morphology and accommodative function of the vitreous zonule in human and monkey eyes.

    Science.gov (United States)

    Lütjen-Drecoll, Elke; Kaufman, Paul L; Wasielewski, Rainer; Ting-Li, Lin; Croft, Mary Ann

    2010-03-01

    To explore the attachments of the posterior zonule and vitreous in relation to accommodation and presbyopia in monkeys and humans. Novel scanning electron microscopy (SEM) and ultrasound biomicroscopy (UBM) techniques were used to visualize the anterior, intermediate, and posterior vitreous zonule and their connections to the ciliary body, vitreous membrane, lens capsule, and ora serrata, and to characterize their age-related changes and correlate them with loss of accommodative forward movement of the ciliary body. alpha-Chymotrypsin was used focally to lyse the vitreous zonule and determine the effect on movement of the accommodative apparatus in monkeys. The vitreous attached to the peripheral lens capsule and the ora serrata directly. The pars plana zonule and the posterior tines of the anterior zonule were separated from the vitreous membrane except for strategically placed attachments, collectively termed the vitreous zonule, that may modulate and smooth the forward and backward movements of the entire system. Age-dependent changes in these relationships correlated significantly with loss of accommodative amplitude. Lysis of the intermediate vitreous zonule partially restored accommodative movement. The vitreous zonule system may help to smoothly translate to the lens the driving forces of accommodation and disaccommodation generated by the ciliary muscle, while maintaining visual focus and protecting the lens capsule and ora serrata from acute tractional forces. Stiffening of the vitreous zonular system may contribute to age-related loss of accommodation and offer a therapeutic target for presbyopia.

  15. Significance of human retinal optic disk localization in various retinal eye diseases

    International Nuclear Information System (INIS)

    Basit, A.

    2011-01-01

    Optic Disk is one of the prominent features in human fundus images. Automatic localization and segmentation of optic disk can help in early diagnosis of diabetic retinopathies and preventing vision loss. In this paper robust method for optic disk detection and extraction of optic disk boundary is proposed based on morphological operations, smoothing filters and markers controlled watershed transform. This method has shown significant improvements in terms of detection and boundaries extraction of optic disk. This method used two types of markers: internal marker and external marker. These markers first modified the gradient magnitude image and then watershed transformation is applied on this modified gradient magnitude image for boundary extraction. The proposed method has optic disk detection success rate of 100% for Shifa and 87.6% for DIARETDB1 databases. Proposed method achieved average overlap of 51.19% for DIARETDB1 database and 73.98% for Shifa database which is higher than currents methods. Experimental results clearly demonstrate an efficient performance of the proposed algorithm. (author)

  16. A macaque's-eye view of human insertions and deletions: differences in mechanisms.

    Directory of Open Access Journals (Sweden)

    Erika M Kvikstad

    2007-09-01

    Full Text Available Insertions and deletions (indels cause numerous genetic diseases and lead to pronounced evolutionary differences among genomes. The macaque sequences provide an opportunity to gain insights into the mechanisms generating these mutations on a genome-wide scale by establishing the polarity of indels occurring in the human lineage since its divergence from the chimpanzee. Here we apply novel regression techniques and multiscale analyses to demonstrate an extensive regional indel rate variation stemming from local fluctuations in divergence, GC content, male and female recombination rates, proximity to telomeres, and other genomic factors. We find that both replication and, surprisingly, recombination are significantly associated with the occurrence of small indels. Intriguingly, the relative inputs of replication versus recombination differ between insertions and deletions, thus the two types of mutations are likely guided in part by distinct mechanisms. Namely, insertions are more strongly associated with factors linked to recombination, while deletions are mostly associated with replication-related features. Indel as a term misleadingly groups the two types of mutations together by their effect on a sequence alignment. However, here we establish that the correct identification of a small gap as an insertion or a deletion (by use of an outgroup is crucial to determining its mechanism of origin. In addition to providing novel insights into insertion and deletion mutagenesis, these results will assist in gap penalty modeling and eventually lead to more reliable genomic alignments.

  17. Relationship of cumulative low-level dose of ionizing radiation on human eye lens and occurrence of cataract

    International Nuclear Information System (INIS)

    Deolalikar, Raghavendra

    2015-01-01

    International Commission on Radiological Protection (ICRP), issued a statement on Tissue Reaction, lowering the equivalent dose limit for eye lens for occupational exposure to 20 mSv per year. With a view to determine presence of any relationship between the cumulative low-level occupational radiation dose to the eye lens and occurrence of cataract, departmental records of the annual medical examination of employees of Narora Atomic Power Plant were examined along with the NAPS eye camps and surgical records of the employees. Analysis of the data showed no demonstrable definite relationship between the two. The analysis of the data and the observations are discussed in this paper. (author)

  18. Fundamental length

    International Nuclear Information System (INIS)

    Pradhan, T.

    1975-01-01

    The concept of fundamental length was first put forward by Heisenberg from purely dimensional reasons. From a study of the observed masses of the elementary particles known at that time, it is sumrised that this length should be of the order of magnitude 1 approximately 10 -13 cm. It was Heisenberg's belief that introduction of such a fundamental length would eliminate the divergence difficulties from relativistic quantum field theory by cutting off the high energy regions of the 'proper fields'. Since the divergence difficulties arise primarily due to infinite number of degrees of freedom, one simple remedy would be the introduction of a principle that limits these degrees of freedom by removing the effectiveness of the waves with a frequency exceeding a certain limit without destroying the relativistic invariance of the theory. The principle can be stated as follows: It is in principle impossible to invent an experiment of any kind that will permit a distintion between the positions of two particles at rest, the distance between which is below a certain limit. A more elegant way of introducing fundamental length into quantum theory is through commutation relations between two position operators. In quantum field theory such as quantum electrodynamics, it can be introduced through the commutation relation between two interpolating photon fields (vector potentials). (K.B.)

  19. Enhancing a CAVE with Eye Tracking System for Human-Computer Interaction Research in 3D Visualization

    National Research Council Canada - National Science Library

    Hix, Deborah

    1999-01-01

    The objective of this award was to purchase and install two ISCAN Inc. Eye Tracking Systems and associated equipment to create a unique set-up for research in fully immersive virtual environments (VEs...

  20. Bruch´s membrane thickness in relationship to axial length.

    Directory of Open Access Journals (Sweden)

    Hai Xia Bai

    Full Text Available To assess a potential role of Bruch´s membrane (BM in the biomechanics of the eye, we measured its thickness and the density of retinal pigment epithelium (RPE cells in various ocular regions in eyes of varying axial length.Human globes, enucleated because of an ocular tumor or end-stage glaucoma were prepared for histological examination. Using light microscopy, the histological slides were histomorphometrically examined applying a digitized image analysis system.The study included 104 eyes with a mean axial length of 27.9±3.2 mm (range:22.6mm-36.5mm. In eyes without congenital glaucoma, BM was significantly thickest (P<0.001 at the ora serrata, followed by the posterior pole, the midpoint between equator and posterior pole (MBEPP, and finally the equator. BM thickness was not significantly correlated with axial length (ora serrata: P = 0.93; equator:P = 0.31; MBEPP:P = 0.15; posterior pole:P = 0.35. RPE cell density in the pre-equatorial region (P = 0.02; regression coefficient r = -0.24 and in the retro-equatorial region (P = 0.03; r = -0.22 decreased with longer axial length, while RPE cell density at the ora serrata (P = 0.35, the MBEPP (P = 0.06; r = -0.19 and the posterior pole (P = 0.38 was not significantly correlated with axial length. Highly myopic eyes with congenital glaucoma showed a tendency towards lower BM thickness and lower RPE cell density at all locations.BM thickness, in contrast to scleral and choroidal thickness, was independent of axial length in eyes without congenital glaucoma. In association with an axial elongation associated decrease in the RPE cell density in the midperiphery, the findings support the notion of a biomechanical role BM may play in the process of emmetropization/myopization.

  1. Typing of Human Mycobacterium avium Isolates in Italy by IS1245-Based Restriction Fragment Length Polymorphism Analysis

    Science.gov (United States)

    Lari, Nicoletta; Cavallini, Michela; Rindi, Laura; Iona, Elisabetta; Fattorini, Lanfranco; Garzelli, Carlo

    1998-01-01

    All but 2 of 63 Mycobacterium avium isolates from distinct geographic areas of Italy exhibited markedly polymorphic, multibanded IS1245 restriction fragment length polymorphism (RFLP) patterns; 2 isolates showed the low-number banding pattern typical of bird isolates. By computer analysis, 41 distinct IS1245 patterns and 10 clusters of essentially identical strains were detected; 40% of the 63 isolates showed genetic relatedness, suggesting the existence of a predominant AIDS-associated IS1245 RFLP pattern. PMID:9817900

  2. Diabetes eye exams

    Science.gov (United States)

    Diabetic retinopathy - eye exams; Diabetes - eye exams; Glaucoma - diabetic eye exam; Macular edema - diabetic eye exam ... if the doctor who takes care of your diabetes checks your eyes, you need an eye exam ...

  3. 'Goats that stare at men'--revisited: do dwarf goats alter their behaviour in response to eye visibility and head direction of a human?

    Science.gov (United States)

    Nawroth, Christian; von Borell, Eberhard; Langbein, Jan

    2016-05-01

    Being able to recognise when one is being observed by someone else is thought to be adaptive during cooperative or competitive events. In particular for prey species, this ability should be of use in the context of predation. A previous study reported that goats (Capra aegagrus hircus) alter their behaviour according to the body and head orientation of a human experimenter. During a food anticipation task, an experimenter remained in a particular posture for 30 s before delivering a reward, and the goats' active anticipation and standing alert behaviour were analysed. To further evaluate the specific mechanisms at work, we here present two additional test conditions. In particular, we investigated the effects of the eye visibility and head orientation of a human experimenter on the behaviour of the goats (N = 7). We found that the level of the subjects' active anticipatory behaviour was highest in the conditions where the experimenter was directing his head and body towards the goat ('Control' and 'Eyes closed' conditions), but the anticipatory behaviour was significantly decreased when the body ('Head only') or the head and body of the experimenter were directed away from the subject ('Back' condition). For standing alert, we found no significant differences between the three conditions in which the experimenter was directing his head towards the subject ('Control', 'Eyes closed' and 'Head only'). This lack of differences in the expression of standing alert suggests that goats evaluate the direction of a human's head as an important cue in their anticipatory behaviour. However, goats did not respond to the visibility of the experimenter's eyes alone.

  4. Animal models to assess the therapeutic efficacy of human serum and serum-converted platelet lysates for dry eye syndrome: Seeing is believing.

    Science.gov (United States)

    Tseng, Ching-Li; Seghatchian, Jerard; Burnouf, Thierry

    2015-08-01

    There is much interest in the clinical use of serum-converted human blood or platelet concentrates in regenerative medicine, most specifically for wound healing and tissue repair of soft and hard tissues. The scientific rationale supporting the clinical efficacy of these preparations is based on the expectation that their physiological mixture of natural growth factors can orchestrate cell expansion and differentiation in vivo. However, a lack of standardization and regulatory oversight of these blood materials maintain a perception of uncertainty in the scientific and medical community on the value of these preparations for some clinical indications. More studies are needed to understand the mechanism of action underlying their expected efficacy and standardize their use, and benefit from their biological versatility. One application of serum is as eye drop for treating dry eye syndrome (DES), a multifactorial disease of the ocular surface, which has a prevalence of 15% of more in the population. DES can lead to chronic inflammation of the ocular surface, surface impairment in the cornea and conjunctiva, and, in patients with Sjogren syndrome, result in a disruption of the ocular surface epithelium. Objective experimental assessment of safety and efficacy of serum eye drops can help establish scientific rationale in optimal product composition and use. This can be achieved, first, through cell cultures with relevant cell models, before considering, then, animal studies using DES animal models. Several models have been evaluated and are reported in this concise review. The model we have developed encompasses the use of rabbits, where their eyes are treated with 0.1% benzalkonium chloride (BAC), a common preservative in ophthalmic agents, 3 times daily for 4 weeks. This relatively mild treatment results in moderate DES pathology, with a stable shortage of tear secretion throughout a 7-week study period, which we found suitable for assessing efficacy of serum eye

  5. Dose conversion coefficients for monoenergetic electrons incident on a realistic human eye model with different lens cell populations.

    Science.gov (United States)

    Nogueira, P; Zankl, M; Schlattl, H; Vaz, P

    2011-11-07

    The radiation-induced posterior subcapsular cataract has long been generally accepted to be a deterministic effect that does not occur at doses below a threshold of at least 2 Gy. Recent epidemiological studies indicate that the threshold for cataract induction may be much lower or that there may be no threshold at all. A thorough study of this subject requires more accurate dose estimates for the eye lens than those available in ICRP Publication 74. Eye lens absorbed dose per unit fluence conversion coefficients for electron irradiation were calculated using a geometrical model of the eye that takes into account different cell populations of the lens epithelium, together with the MCNPX Monte Carlo radiation transport code package. For the cell population most sensitive to ionizing radiation-the germinative cells-absorbed dose per unit fluence conversion coefficients were determined that are up to a factor of 4.8 higher than the mean eye lens absorbed dose conversion coefficients for electron energies below 2 MeV. Comparison of the results with previously published values for a slightly different eye model showed generally good agreement for all electron energies. Finally, the influence of individual anatomical variability was quantified by positioning the lens at various depths below the cornea. A depth difference of 2 mm between the shallowest and the deepest location of the germinative zone can lead to a difference between the resulting absorbed doses of up to nearly a factor of 5000 for electron energy of 0.7 MeV.

  6. Dose conversion coefficients for monoenergetic electrons incident on a realistic human eye model with different lens cell populations

    International Nuclear Information System (INIS)

    Nogueira, P; Vaz, P; Zankl, M; Schlattl, H

    2011-01-01

    The radiation-induced posterior subcapsular cataract has long been generally accepted to be a deterministic effect that does not occur at doses below a threshold of at least 2 Gy. Recent epidemiological studies indicate that the threshold for cataract induction may be much lower or that there may be no threshold at all. A thorough study of this subject requires more accurate dose estimates for the eye lens than those available in ICRP Publication 74. Eye lens absorbed dose per unit fluence conversion coefficients for electron irradiation were calculated using a geometrical model of the eye that takes into account different cell populations of the lens epithelium, together with the MCNPX Monte Carlo radiation transport code package. For the cell population most sensitive to ionizing radiation-the germinative cells-absorbed dose per unit fluence conversion coefficients were determined that are up to a factor of 4.8 higher than the mean eye lens absorbed dose conversion coefficients for electron energies below 2 MeV. Comparison of the results with previously published values for a slightly different eye model showed generally good agreement for all electron energies. Finally, the influence of individual anatomical variability was quantified by positioning the lens at various depths below the cornea. A depth difference of 2 mm between the shallowest and the deepest location of the germinative zone can lead to a difference between the resulting absorbed doses of up to nearly a factor of 5000 for electron energy of 0.7 MeV.

  7. Neural correlates of the eye dominance effect in human face perception: the left-visual-field superiority for faces revisited.

    Science.gov (United States)

    Jung, Wookyoung; Kang, Joong-Gu; Jeon, Hyeonjin; Shim, Miseon; Sun Kim, Ji; Leem, Hyun-Sung; Lee, Seung-Hwan

    2017-08-01

    Faces are processed best when they are presented in the left visual field (LVF), a phenomenon known as LVF superiority. Although one eye contributes more when perceiving faces, it is unclear how the dominant eye (DE), the eye we unconsciously use when performing a monocular task, affects face processing. Here, we examined the influence of the DE on the LVF superiority for faces using event-related potentials. Twenty left-eye-dominant (LDE group) and 23 right-eye-dominant (RDE group) participants performed the experiments. Face stimuli were randomly presented in the LVF or right visual field (RVF). The RDE group exhibited significantly larger N170 amplitudes compared with the LDE group. Faces presented in the LVF elicited N170 amplitudes that were significantly more negative in the RDE group than they were in the LDE group, whereas the amplitudes elicited by stimuli presented in the RVF were equivalent between the groups. The LVF superiority was maintained in the RDE group but not in the LDE group. Our results provide the first neural evidence of the DE's effects on the LVF superiority for faces. We propose that the RDE may be more biologically specialized for face processing. © The Author (2017). Published by Oxford University Press.

  8. Xeno-Free and Defined Human Embryonic Stem Cell-Derived Retinal Pigment Epithelial Cells Functionally Integrate in a Large-Eyed Preclinical Model

    Directory of Open Access Journals (Sweden)

    Alvaro Plaza Reyes

    2016-01-01

    Full Text Available Human embryonic stem cell (hESC-derived retinal pigment epithelial (RPE cells could replace lost tissue in geographic atrophy (GA but efficacy has yet to be demonstrated in a large-eyed model. Also, production of hESC-RPE has not yet been achieved in a xeno-free and defined manner, which is critical for clinical compliance and reduced immunogenicity. Here we describe an effective differentiation methodology using human laminin-521 matrix with xeno-free and defined medium. Differentiated cells exhibited characteristics of native RPE including morphology, pigmentation, marker expression, monolayer integrity, and polarization together with phagocytic activity. Furthermore, we established a large-eyed GA model that allowed in vivo imaging of hESC-RPE and host retina. Cells transplanted in suspension showed long-term integration and formed polarized monolayers exhibiting phagocytic and photoreceptor rescue capacity. We have developed a xeno-free and defined hESC-RPE differentiation method and present evidence of functional integration of clinically compliant hESC-RPE in a large-eyed disease model.

  9. Gaze-related mimic word activates the frontal eye field and related network in the human brain: an fMRI study.

    Science.gov (United States)

    Osaka, Naoyuki; Osaka, Mariko

    2009-09-18

    This is an fMRI study demonstrating new evidence that a mimic word highly suggestive of an eye gaze, heard by the ear, significantly activates the frontal eye field (FEF), inferior frontal gyrus (IFG), dorsolateral premotor area (PMdr) and superior parietal lobule (SPL) connected with the frontal-parietal network. However, hearing a non-sense words that did not imply gaze under the same task does not activate this area in humans. We concluded that the FEF would be a critical area for generating/processing an active gaze, evoked by an onomatopoeia word that implied gaze closely associated with social skill. We suggest that the implied active gaze may depend on prefrontal-parietal interactions that modify cognitive gaze led by spatial visual attention associated with the SPL.

  10. An ocular biomechanic model for dynamic simulation of different eye movements.

    Science.gov (United States)

    Iskander, J; Hossny, M; Nahavandi, S; Del Porto, L

    2018-04-11

    Simulating and analysing eye movement is useful for assessing visual system contribution to discomfort with respect to body movements, especially in virtual environments where simulation sickness might occur. It can also be used in the design of eye prosthesis or humanoid robot eye. In this paper, we present two biomechanic ocular models that are easily integrated into the available musculoskeletal models. The model was previously used to simulate eye-head coordination. The models are used to simulate and analyse eye movements. The proposed models are based on physiological and kinematic properties of the human eye. They incorporate an eye-globe, orbital suspension tissues and six muscles with their connective tissues (pulleys). Pulleys were incorporated in rectus and inferior oblique muscles. The two proposed models are the passive pulleys and the active pulleys models. Dynamic simulations of different eye movements, including fixation, saccade and smooth pursuit, are performed to validate both models. The resultant force-length curves of the models were similar to the experimental data. The simulation results show that the proposed models are suitable to generate eye movement simulations with results comparable to other musculoskeletal models. The maximum kinematic root mean square error (RMSE) is 5.68° and 4.35° for the passive and active pulley models, respectively. The analysis of the muscle forces showed realistic muscle activation with increased muscle synergy in the active pulley model. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Shifting the IGF-axis: An age-related decline in human tear IGF-1 correlates with clinical signs of dry eye.

    Science.gov (United States)

    Patel, Roshni; Zhu, Meifang; Robertson, Danielle M

    2018-02-06

    The human corneal epithelium expresses both the insulin-like growth factor type 1 receptor (IGF-1R) and the IGF-1R/insulin receptor (INSR) hybrid. Despite the previous identification of IGF-1 in human tear fluid, little is known regarding the regulation of IGF-1 in tear fluid and its role in corneal epithelial homeostasis. In the present study, we investigated the impact of biological parameters on the concentration of human tear levels of IGF-1. Tear levels of IGF-1 were measured in 41 healthy, human volunteers without any reported symptoms of dry eye. All volunteers underwent standard biomicroscopic examination of the cornea and tear film. In a subgroup of volunteers, corneal staining with sodium fluorescein, tear film break up time and tear production using a Schirmer's test strip were measured to assess clinical signs of dry eye. Tears were collected from the inferior tear meniscus using glass microcapillary tubes and IGF-1 levels were measured using a solid phase sandwich ELISA. Tear levels of IGF-1 were highest in young adults and significantly decreased in older adults (P = 0.003). There were no differences in tear IGF-1 between males and females (P = 0.628). Tear IGF-1 levels were correlated with tear film break up time (R = 0.738) and tear production (R = 0.826). These data indicate that there is a progressive decline in tear IGF-1 due to aging that is associated with clinical signs of dry eye. This effect is likely due to age-related changes in the lacrimal gland. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Eye Injuries

    Science.gov (United States)

    ... that you could lose your vision. Most eye injuries are preventable. If you play sports or work in certain jobs, you may need protection. The most common type of injury happens when something irritates the ...

  13. Eyes - bulging

    Science.gov (United States)

    ... different ages. In: Lambert SR, Lyons CJ, eds. Taylor and Hoyt's Pediatric Ophthalmology and Strabismus . 5th ed. Philadelphia, PA: Elsevier; 2017:chap 96. Orge FH, Grigorian F. Examination and common problems of the neonatal eye. ...

  14. Reduction of the immunostainable length of the hippocampal dentate granule cells’ primary cilia in 3xAD-transgenic mice producing human Aβ1-42 and tau

    International Nuclear Information System (INIS)

    Chakravarthy, Balu; Gaudet, Chantal; Ménard, Michel; Brown, Leslie; Atkinson, Trevor; LaFerla, Frank M.; Ito, Shingo; Armato, Ubaldo; Dal Prà, Ilaria; Whitfield, James

    2012-01-01

    Highlights: ► Aβ and tau-induced neurofibrillary tangles play a key role in Alzheimer’s disease. ► Aβ 1-42 and mutant tau protein together reduce the primary cilium length. ► This shortening likely reduces cilium-dependent neurogenesis and memory function. ► This provides a model of an Aβ/tau targeting of a neuronal signaling organelle. -- Abstract: The hippocampal dentate gyrus is one of the two sites of continuous neurogenesis in adult rodents and humans. Virtually all dentate granule cells have a single immobile cilium with a microtubule spine or axoneme covered with a specialized cell membrane loaded with receptors such as the somatostatin receptor 3 (SSTR3), and the p75 neurotrophin receptor (p75 NTR ). The signals from these receptors have been reported to stimulate neuroprogenitor proliferation and the post-mitotic maturation of newborn granule cells into functioning granule cells. We have found that in 6–24-months-old triple transgenic Alzheimer’s disease model mice (3xTg-AD) producing both Aβ 1-42 and the mutant human tau protein tau P301L, the dentate granule cells still had immunostainable SSTR3- and p75 NTR -bearing cilia but they were only half the length of the immunostained cilia in the corresponding wild-type mice. However, the immunostainable length of the granule cell cilia was not reduced either in 2xTg-AD mice accumulating large amounts of Aβ 1-42 or in mice accumulating only a mutant human tau protein. Thus it appears that a combination of Aβ 1-42 and tau protein accumulation affects the levels of functionally important receptors in 3xTg-AD mice. These observations raise the important possibility that structural and functional changes in granule cell cilia might have a role in AD.

  15. Drug resistance is conferred on the model yeast Saccharomyces cerevisiae by expression of full-length melanoma-associated human ATP-binding cassette transporter ABCB5.

    Science.gov (United States)

    Keniya, Mikhail V; Holmes, Ann R; Niimi, Masakazu; Lamping, Erwin; Gillet, Jean-Pierre; Gottesman, Michael M; Cannon, Richard D

    2014-10-06

    ABCB5, an ATP-binding cassette (ABC) transporter, is highly expressed in melanoma cells, and may contribute to the extreme resistance of melanomas to chemotherapy by efflux of anti-cancer drugs. Our goal was to determine whether we could functionally express human ABCB5 in the model yeast Saccharomyces cerevisiae, in order to demonstrate an efflux function for ABCB5 in the absence of background pump activity from other human transporters. Heterologous expression would also facilitate drug discovery for this important target. DNAs encoding ABCB5 sequences were cloned into the chromosomal PDR5 locus of a S. cerevisiae strain in which seven endogenous ABC transporters have been deleted. Protein expression in the yeast cells was monitored by immunodetection using both a specific anti-ABCB5 antibody and a cross-reactive anti-ABCB1 antibody. ABCB5 function in recombinant yeast cells was measured by determining whether the cells possessed increased resistance to known pump substrates, compared to the host yeast strain, in assays of yeast growth. Three ABCB5 constructs were made in yeast. One was derived from the ABCB5-β mRNA, which is highly expressed in human tissues but is a truncation of a canonical full-size ABC transporter. Two constructs contained full-length ABCB5 sequences: either a native sequence from cDNA or a synthetic sequence codon-harmonized for S. cerevisiae. Expression of all three constructs in yeast was confirmed by immunodetection. Expression of the codon-harmonized full-length ABCB5 DNA conferred increased resistance, relative to the host yeast strain, to the putative substrates rhodamine 123, daunorubicin, tetramethylrhodamine, FK506, or clorgyline. We conclude that full-length ABCB5 can be functionally expressed in S. cerevisiae and confers drug resistance.

  16. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Stories Español Eye Health / Eye Health A-Z Dry Eye Sections What Is Dry Eye? Dry Eye Symptoms ... of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué es el ojo seco? ...

  17. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Español Eye Health / Eye Health A-Z Dry Eye Sections What Is Dry Eye? Dry Eye Symptoms ... Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué es el ojo seco? ...

  18. Penetrating and Intrastromal Corneal Arcuate Incisions in Rabbit and Human Cadaver Eyes: Manual Diamond Blade and Femtosecond Laser-Created Incisions.

    Science.gov (United States)

    Gray, Brad; Binder, Perry S; Huang, Ling C; Hill, Jim; Salvador-Silva, Mercedes; Gwon, Arlene

    2016-07-01

    To compare morphologic differences between freehand diamond or femtosecond laser-assisted penetrating and intrastromal arcuate incisions. Freehand diamond blade, corneal arcuate incisions (180° apart, 60° arc lengths) and 150 kHz femtosecond laser (80% scheimpflug pachymetry depth corneal thickness) arcuate incisions were performed in rabbits. Intrastromal arcuate incisions (100 μm above Descemet's membrane, 100 μm below epithelium) were performed in rabbit corneas (energy 1.2 μJ, spot line separation 3 × 3 μm, 90° side cut angle). Eyes were examined by slit lamp and light microscopy up to 47 days post-procedure. Freehand diamond blade penetrating incisions, and femtosecond laser penetrating and intrastromal arcuate incisions (energy 1.8 μJ, spot line separation 2 × 2 μm) were performed in cadaver eyes. Optical coherence tomography was performed immediately after surgery and the corneas were fixed for light scanning and transmission electron microscopy. The rabbit model showed anterior stromal inflammation with epithelial hyperplasia in penetrating blade and laser penetrating wounds. The laser intrastromal and penetrating incisions showed localized constriction of the stromal layers of the cornea near the wound. In cadaver eyes, penetrating wound morphology was similar between blade and laser whereas intrastromal wounds did not affect the cornea above or below incisions. Penetrating femtosecond laser arcuate incisions have more predictable and controlled outcomes shown by less post-operative scarring than incisions performed with a diamond blade. Intrastromal incisions do not affect uncut corneal layers as demonstrated by histopathology. The femtosecond laser has significant advantages in its ability to make intrastromal incisions which are not achievable by traditional freehand or mechanical diamond blades.

  19. The full-length E1-circumflexE4 protein of human papillomavirus type 18 modulates differentiation-dependent viral DNA amplification and late gene expression

    International Nuclear Information System (INIS)

    Wilson, Regina; Ryan, Gordon B.; Knight, Gillian L.; Laimins, Laimonis A.; Roberts, Sally

    2007-01-01

    Activation of the productive phase of the human papillomavirus (HPV) life cycle in differentiated keratinocytes is coincident with high-level expression of E1-circumflexE4 protein. To determine the role of E1-circumflexE4 in the HPV replication cycle, we constructed HPV18 mutant genomes in which expression of the full-length E1-circumflexE4 protein was abrogated. Undifferentiated keratinocytes containing mutant genomes showed enhanced proliferation when compared to cells containing wildtype genomes, but there were no differences in maintenance of viral episomes. Following differentiation, cells with mutant genomes exhibited reduced levels of viral DNA amplification and late gene expression, compared to wildtype genome-containing cells. This indicates that HPV18 E1-circumflexE4 plays an important role in regulating HPV late functions, and it may also function in the early phase of the replication cycle. Our finding that full-length HPV18 E1-circumflexE4 protein plays a significant role in promoting viral genome amplification concurs with a similar report with HPV31, but is in contrast to an HPV11 study where viral DNA amplification was not dependent on full-length E1-circumflexE4 expression, and to HPV16 where only C-terminal truncations in E1-circumflexE4 abrogated vegetative genome replication. This suggests that type-specific differences exist between various E1-circumflexE4 proteins

  20. Establishment of a new immortalized human corneal epithelial cell line (iHCE-NY1) for use in evaluating eye irritancy by in vitro test methods.

    Science.gov (United States)

    Yamamoto, Naoki; Kato, Yoshinao; Sato, Atsushi; Hiramatsu, Noriko; Yamashita, Hiromi; Ohkuma, Mahito; Miyachi, Ei-Ichi; Horiguchi, Masayuki; Hirano, Koji; Kojima, Hajime

    2016-08-01

    In vitro test methods that use human corneal epithelial cells to evaluate the eye irritation potency of chemical substances do not use human corneal epithelium because it has been difficult to maintain more than four passages. In this study, we make a new cell line comprising immortalized human corneal epithelial cells (iHCE-NY1). The IC50 of iHCE-NY1 cells is slightly higher than that of Statens Seruminstitut Rabbit Cornea (SIRC) cells, which are currently used in some in vitro test methods. CDKN1A in iHCE-NY1 cells was used as a marker of gene expression to indicate cell cycle activity. This enabled us to evaluate cell recovery characteristics at concentrations lower than the IC50 of cytotoxic tests.

  1. Effect of axial length on laser spot size during photodynamic therapy: an experimental study in monkeys.

    Science.gov (United States)

    Kondo, Mineo; Ito, Yasuki; Miyata, Kentaro; Kondo, Nagako; Ishikawa, Kohei; Terasaki, Hiroko

    2006-01-01

    To investigate the effect of shorter axial length on the laser spot size and laser energy during photodynamic therapy (PDT) in monkeys. Experimental study with four rhesus monkeys. PDT was performed on the normal retina of monkeys whose ocular axial lengths are shorter (19.55 to 20.25 mm) than that of humans. After the PDT, the eyes were enucleated, and the diameter of the irradiated laser spot was measured with a microcaliper. The area of actual laser spot was only 0.56 to 0.61 times of the planned area, which indicated that the laser energy/area was 1.64 to 1.78 times more intense than planned initially. These results are the in vivo demonstration that the diameter of PDT laser spot is smaller for eyes with shorter axial lengths.

  2. Increased mRNA expression of a laminin-binding protein in human colon carcinoma: Complete sequence of a full-length cDNA encoding the protein

    International Nuclear Information System (INIS)

    Yow, Hsiukang; Wong, Jau Min; Chen, Hai Shiene; Lee, C.; Steele, G.D. Jr.; Chen, Lanbo

    1988-01-01

    Reliable markers to distinguish human colon carcinoma from normal colonic epithelium are needed particularly for poorly differentiated tumors where no useful marker is currently available. To search for markers the authors constructed cDNA libraries from human colon carcinoma cell lines and screened for clones that hybridize to a greater degree with mRNAs of colon carcinomas than with their normal counterparts. Here they report one such cDNA clone that hybridizes with a 1.2-kilobase (kb) mRNA, the level of which is ∼9-fold greater in colon carcinoma than in adjacent normal colonic epithelium. Blot hybridization of total RNA from a variety of human colon carcinoma cell lines shows that the level of this 1.2-kb mRNA in poorly differentiated colon carcinomas is as high as or higher than that in well-differentiated carcinomas. Molecular cloning and complete sequencing of cDNA corresponding to the full-length open reading frame of this 1.2-kb mRNA unexpectedly show it to contain all the partial cDNA sequence encoding 135 amino acid residues previously reported for a human laminin receptor. The deduced amino acid sequence suggests that this putative laminin-binding protein from human colon carcinomas consists of 295 amino acid residues with interesting features. There is an unusual C-terminal 70-amino acid segment, which is trypsin-resistant and highly negatively charged

  3. Isolation and characterization of DNA probes from a flow-sorted human chromosome 8 library that detect restriction fragment length polymorphism (RFLP).

    Science.gov (United States)

    Wood, S; Starr, T V; Shukin, R J

    1986-01-01

    We have used a recombinant DNA library constructed from flow-sorted human chromosome 8 as a source of single-copy human probes. These probes have been screened for restriction fragment length polymorphism (RFLP) by hybridization to Southern transfers of genomic DNA from five unrelated individuals. We have detected six RFLPs distributed among four probes after screening 741 base pairs for restriction site variation. These RFLPs all behave as codominant Mendelian alleles. Two of the probes detect rare variants, while the other two detect RFLPs with PIC values of .36 and .16. Informative probes will be useful for the construction of a linkage map for chromosome 8 and for the localization of mutant alleles to this chromosome. Images Fig. 1 PMID:2879441

  4. Using the human eye to image space radiation or the history and status of the light flash phenomena

    Energy Technology Data Exchange (ETDEWEB)

    Fuglesang, C [European Astronaut Centre, ESA, Cologne, Germany and Royal Institute of Technolgy (KTH), Stockholm (Sweden)], E-mail: Christer.fuglesang@esa.int

    2007-10-01

    About 80% of people who travel in space experience sudden phosphenes, commonly called light flashes (LF). Although the detailed physiological process is still not known, the LFs are caused by particles in the cosmic radiation field. Indeed, by counting LFs one can even make a crude image of the radiation environment around the Earth. Studies on the space station Mir with the SilEye experiment correlated LFs with charged particles traversing the eye. It was found that a nucleus in the radiation environment has roughly a 1% probability of causing a light flash, whereas the proton's probability is almost three orders of magnitude less. As a function of linear energy transfer (LET), the probability increased with ionization above 10 keV/{mu}m, reaching about 5% at 50 keV/{mu}m. The investigations are continuing on the International Space Station (ISS) with the Alteino/SileEye-3 detector, which is also a precursor to the large Anomalous Long Term Effects on Astronauts (ALTEA) facility. These detectors are also measuring-imaging-the radiation environment inside the ISS, which will be compared to Geant4 simulations from the DESIRE project. To further the understanding of the LF phenomena, a survey among current NASA and ESA astronauts was recently conducted. The LFs are predominantly noticed before sleep and some respondents even thought it disturbed their sleep. The LFs appear white, have elongated shapes, and most interestingly, often come with a sense of motion. Comparing the shapes quoted from space observations with ground experiments done by researchers in the 1970s, it seems likely that some 5-10% of the LFs in space are due to Cherenkov light in the eye. However, the majority is most likely caused by some direct interaction in the retina.

  5. Blood Perfusion in Human Eyelid Skin Flaps Examined by Laser Speckle Contrast Imaging-Importance of Flap Length and the Use of Diathermy.

    Science.gov (United States)

    Nguyen, Cu Dinh; Hult, Jenny; Sheikh, Rafi; Tenland, Kajsa; Dahlstrand, Ulf; Lindstedt, Sandra; Malmsjö, Malin

    2017-10-11

    It is well known that blood perfusion is important for the survival of skin flaps. As no study has been conducted to investigate how the blood perfusion in human eyelid skin flaps is affected by the flap length and diathermy, the present study was carried out to investigate these in patients. Fifteen upper eyelids were dissected as part of a blepharoplastic procedure, releasing a 30-mm long piece of skin, while allowing the 5 mm wide distal part of the skin to remain attached, to mimic a skin flap (hereafter called a "skin flap"). Blood perfusion was measured before and after repeated diathermy, using laser speckle contrast imaging. Blood perfusion decreased from the base to the tip of the flap: 5 mm from the base, the perfusion was 69%, at 10 mm it was 40%, at 15 mm it was 20%, and at 20 mm it was only 13% of baseline values. Diathermy further decreased blood perfusion (measured 15 mm from the base) to 13% after applying diathermy for the first time, to 6% after the second and to 4% after the third applications of diathermy. Blood perfusion falls rapidly with distance from the base of skin flaps on the human eyelid, and diathermy reduces blood perfusion even further. Clinically, it may be advised that flaps with a width of 5 mm be no longer than 15 mm (i.e., a width:length ratio of 1:3), and that the use of diathermy should be carefully considered.

  6. Immediate Effects of 3% Diquafosol and 0.1% Hyaluronic Acid Ophthalmic Solution on Tear Break-Up Time in Normal Human Eyes.

    Science.gov (United States)

    Nam, Ki Tae; Ahn, So Min; Eom, Youngsub; Kim, Hyo Myung; Song, Jong Suk

    2015-12-01

    The purpose of this study was to evaluate the immediate effect of 3% diquafosol ophthalmic solution on tear break-up time (TBUT) in normal human eyes, and to compare it with that of saline and 0.1% hyaluronate ophthalmic solution. Cross sectional comparative study in the first study, 10 healthy volunteers underwent topical application of 2 different ophthalmic solutions in each eye. Saline was randomly applied to one eye and 3% diquafosol ophthalmic solution was added to the fellow eye. TBUT was measured and video recorded before application and at 5, 10, 15, and 20 min after. The TBUT in each eye was compared at each time point with regard to the 2 different ophthalmic solutions. In the second study, another 10 healthy volunteers were included. The same methods were used to compare the immediate effects of 0.1% hyaluronate and 3% diquafosol ophthalmic solution application on TBUT. In the first study, topical instillation of saline did not increase TBUT. However, 3% diquafosol significantly increased TBUT for up to 15 min after application. At every time point, the TBUT increased more significantly from baseline in the diquafosol group than it did in the saline group. In the second study, 0.1% hyaluronate increased TBUT for up to 5 min after application, while 3% diquafosol increased TBUT for up to 15 min. Although the TBUT changes after 5 min were not significantly different between the 2 groups, the TBUT changes at 10, 15, and 20 min were significantly greater in the 3% diquafosol group than they were in the 0.1% hyaluronic acid group (+1.58 ± 0.82 vs. +0.53 ± 1.36 at 10 min, +0.67 ± 0.91 vs. -0.04 ± 1.29 at 15 min, and -0.06 ± 0.96 vs. -0.59 ± 0.90, diquafosol group vs. hyaluronic acid group). One drop of 3% diquafosol increased TBUT for up to 15 min after application. The immediate effect of 3% diquafosol on TBUT was greater than that of saline and even that of 1% hyaluronate ophthalmic solution.

  7. 21 CFR 878.4440 - Eye pad.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Eye pad. 878.4440 Section 878.4440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4440 Eye pad. (a) Identification. An eye pad is...

  8. Eye emergencies

    Science.gov (United States)

    ... eye can be caused by a work-related accident. It can also be caused by common household ... hammers, or other striking tools Working with toxic chemicals Cycling or when in windy and ... A.D.A.M.'s editorial policy , editorial process and privacy policy . A.D.A.M. is ...

  9. Eye Cancer

    Science.gov (United States)

    ... layer of tissue underneath the retina that contains connective tissue and melanocytes, which are pigmented (colored) cells, and nourishes the inside of the eye. The choroid is the most common site for a tumor. Types of intraocular cancer The most common intraocular cancer in adults is ...

  10. Eye trauma

    African Journals Online (AJOL)

    2011-02-02

    Feb 2, 2011 ... Note your findings in an orderly fashion: orbit, lids, conjunctiva, cornea, anterior chamber, iris, pupil reaction, lens, fundus. • Stain cornea with fluorescein. It is advisable to examine the eye as soon as possible since a delay will invariably lead to lid swelling, making the examination far more difficult. This can ...

  11. Training for eye contact modulates gaze following in dogs.

    Science.gov (United States)

    Wallis, Lisa J; Range, Friederike; Müller, Corsin A; Serisier, Samuel; Huber, Ludwig; Virányi, Zsófia

    2015-08-01

    Following human gaze in dogs and human infants can be considered a socially facilitated orientation response, which in object choice tasks is modulated by human-given ostensive cues. Despite their similarities to human infants, and extensive skills in reading human cues in foraging contexts, no evidence that dogs follow gaze into distant space has been found. We re-examined this question, and additionally whether dogs' propensity to follow gaze was affected by age and/or training to pay attention to humans. We tested a cross-sectional sample of 145 border collies aged 6 months to 14 years with different amounts of training over their lives. The dogs' gaze-following response in test and control conditions before and after training for initiating eye contact with the experimenter was compared with that of a second group of 13 border collies trained to touch a ball with their paw. Our results provide the first evidence that dogs can follow human gaze into distant space. Although we found no age effect on gaze following, the youngest and oldest age groups were more distractible, which resulted in a higher number of looks in the test and control conditions. Extensive lifelong formal training as well as short-term training for eye contact decreased dogs' tendency to follow gaze and increased their duration of gaze to the face. The reduction in gaze following after training for eye contact cannot be explained by fatigue or short-term habituation, as in the second group gaze following increased after a different training of the same length. Training for eye contact created a competing tendency to fixate the face, which prevented the dogs from following the directional cues. We conclude that following human gaze into distant space in dogs is modulated by training, which may explain why dogs perform poorly in comparison to other species in this task.

  12. Analysis of Eye Care Services in Yemen

    OpenAIRE

    Saleh A. Al-Akily; Mutahar Y. Al-Shaer; Mahfouth A. Bamashmus; Abdulmoghni O. Al-Barrag; Tawfik K. Alkhatib; Hisham A. Al-Akhlee

    2017-01-01

    Purpose: The objective of this study was to undertake an analysis of the eye care services situation in Yemen and to assess ophthalmic human resources, eye units’ ownership and ophthalmic equipments. Methods: Eye care providers were surveyed by a standardized questionnaire which was sent to the 184 eye units in governmental, university, military, private and charity clinics and hospitals in Yemen and covered the period between 01 January to 31 December 2012. The questionnaire determined l...

  13. Monitoring of antibiotic-induced alterations in the human intestinal microflora and detection of probiotic strains by use of terminal restriction fragment length polymorphism.

    Science.gov (United States)

    Jernberg, Cecilia; Sullivan, Asa; Edlund, Charlotta; Jansson, Janet K

    2005-01-01

    Terminal restriction fragment length polymorphism (T-RFLP) was investigated as a tool for monitoring the human intestinal microflora during antibiotic treatment and during ingestion of a probiotic product. Fecal samples from eight healthy volunteers were taken before, during, and after administration of clindamycin. During treatment, four subjects were given a probiotic, and four subjects were given a placebo. Changes in the microbial intestinal community composition and relative abundance of specific microbial populations in each subject were monitored by using viable counts and T-RFLP fingerprints. T-RFLP was also used to monitor specific bacterial populations that were either positively or negatively affected by clindamycin. Some dominant bacterial groups, such as Eubacterium spp., were easily monitored by T-RFLP, while they were hard to recover by cultivation. Furthermore, the two probiotic Lactobacillus strains were easily tracked by T-RFLP and were shown to be the dominant Lactobacillus community members in the intestinal microflora of subjects who received the probiotic.

  14. Diclofenac protects cultured human corneal epithelial cells against hyperosmolarity and ameliorates corneal surface damage in a rat model of dry eye.

    Science.gov (United States)

    Sawazaki, Ryoichi; Ishihara, Tomoaki; Usui, Shinya; Hayashi, Erika; Tahara, Kayoko; Hoshino, Tatsuya; Higuchi, Akihiro; Nakamura, Shigeru; Tsubota, Kazuo; Mizushima, Tohru

    2014-04-21

    Dry eye syndrome (DES) is characterized by an increase in tear osmolarity and induction of the expression and nuclear localization of an osmoprotective transcription factor (nuclear factor of activated T-cells 5 [NFAT5]) that plays an important role in providing protection against hyperosmotic tears. In this study, we screened medicines already in clinical use with a view of finding compounds that protect cultured human corneal epithelial cells against hyperosmolarity-induced cell damage. Viable cell number was determined by the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) method and cellular NFAT5 level was measured by immunoblotting. The rat model for DES was developed by removal of the lacrimal glands, with an assessment of corneal surface damage based on levels of fluorescein staining and epithelial apoptosis. Some nonsteroidal anti-inflammatory drugs (NSAIDs), including diclofenac sodium (diclofenac), were identified during the screening procedure. These NSAIDs were able to suppress hyperosmolarity-induced apoptosis and cell growth arrest. In contrast, other NSAIDs, including bromfenac sodium (bromfenac), did not exert such a protective action. Treatment of cells with diclofenac, but not bromfenac, stimulated both the nuclear localization and expression of NFAT5 under hyperosmotic conditions. In the rat model for DES, topical administration of diclofenac (but not bromfenac) to eyes reduced corneal surface damage without affecting the volume of tear fluid. Diclofenac appears to protect cells against hyperosmolarity-induced cell damage and NFAT5 would play an important role in this protective action. The findings reported here may also indicate that the topical administration of diclofenac to eyes may be therapeutically beneficial for DES patients.

  15. Evaluation of the transforming growth factor-beta activity in normal and dry eye human tears by CCL-185 cell bioassay.

    Science.gov (United States)

    Zheng, Xiaofen; De Paiva, Cintia S; Rao, Kavita; Li, De-Quan; Farley, William J; Stern, Michael; Pflugfelder, Stephen C

    2010-09-01

    To develop a new bioassay method using human lung epithelial cells (CCL-185) to assess activity of transforming growth factor beta (TGF-beta) in human tear fluid from normal subjects and patients with dry eye. Two epithelial cell lines, mink lung cells (CCL-64) and human lung cells (CCL-185), were compared to detect the active form of TGF-beta by BrdU incorporation (quantitation of cell DNA synthesis) and WST assay (metabolic activity of viable cells). The effect of TGF-beta on the growth of CCL-185 cells was observed microscopically. Human tears from normal control subjects and patients with dry eye (DE) with and without Sjögren syndrome were evaluated for TGF-beta concentration by Luminex microbead assay, and TGF-beta activity by the CCL-185 cell growth inhibition bioassay. The metabolic activity of viable CCL-185 cells, measured by WST, was shown to be proportional to the TGF-beta1 concentration (R = 0.919) and confirmed by BrdU assay (R = 0.969). Compared with CCL-185, metabolic activity of viable cells and DNA synthesis, measured by WST and BrdU incorporation assays, were shown to be less proportional to the TGF-beta1 concentration in the CCL-64 line (R = 0.42 and 0.17, respectively). Coincubation with human anti-TGF-beta1 antibody (MAB-240) yielded a dose-dependent inhibition of TGF-beta1 (0.3 ng/mL) activity. CCL-185 cell growth observed microscopically was noted to decrease in response to increasing TGF-beta1 concentrations. Levels of immuodetectable TGF-beta1 and TGF-beta2 were similar in normal and DE tears. TGF-beta bioactivity in DE human tears measured by the CCL-185 cells assay was found to be higher (9777.5 +/- 10481.9 pg/mL) than those in normal controls (4129.3 +/- 1342.9 pg/mL) (P tears and 37.6% TGF-beta in normal tears were found to be biologically active. The CCL-185 cell assay was found to be a suitable tool for assessing TGF-beta activity in human tears. Tear TGF-beta bioactivity increases in DE, particularly in Sjögren syndrome, where

  16. Cortical dynamics during the preparation of antisaccadic and prosaccadic eye movements in humans in a gap paradigm.

    Directory of Open Access Journals (Sweden)

    Isabel Cordones

    Full Text Available To compare the cortical dynamics of different oculomotor tasks, EEG and eye movements were recorded in 21 volunteers. Using a comprehensive approach, subjects were asked to perform saccadic tasks, which included a saccadic eye movement to a peripheral target (prosaccadic, a movement to the opposite side (antisaccadic, or maintain the gaze fixed (no-go. In mixed trials, prosaccadic, antisaccadic and no-go tasks were indicated by a color square (S1 present for 1900-2500 ms (instructive period. S1 disappeared for 370 ms (gap and a black dot at 8 deg at right or left indicated the beginning of the task. Reaction times, amplitude of eye movements and number of errors were greatest in antisaccadic tasks, suggesting a greater difficulty. The EEG showed a contingent negativity variation (CNV that increased progressively along the instructive period and suddenly during the gap: higher in antisaccadic, followed by prosaccadic and no-go tasks. Principal component analysis (PCA disentangled fronto-central and occipital CNV-related and fronto-central gap-related components. The instructive period was characterized by fronto-central and occipital beta desynchronization (ERD higher in antisaccadic than in no-go and parieto-occipital alpha synchronization higher in no-go than in antisaccadic tasks. During the gap, parieto-occipital beta and alpha ERD were higher in antisaccadic compared to no-go. The gap was further characterized by a fronto-central increase of inter-trial coherence in theta: highest during antisaccadic, followed by prosaccadic and no-go tasks. This phase locking in theta was also accompanied by theta ERS, which was significantly higher in antisaccadic than in the other two tasks. In PCA of spectral power two main components had dynamics similar to those extracted from voltage data, suggesting cross-frequency coupling. These results suggest that the more difficult saccadic tasks are associated with top-down control mediated by frontal cortex

  17. Diabetic Eye Disease

    Science.gov (United States)

    ... Disease, & Other Dental Problems Diabetes & Sexual & Urologic Problems Diabetic Eye Disease What is diabetic eye disease? Diabetic eye disease is a group ... eye diseases that can threaten your sight are Diabetic retinopathy The retina is the inner lining at ...

  18. About the Eye

    Medline Plus

    Full Text Available ... eye behind the iris that helps to focus light on the retina. It allows the eye to ... of the eye. It regulates the amount of light entering the eye through the pupil. Pupil (PYOO- ...

  19. Eye Movement Disorders

    Science.gov (United States)

    ... work properly. There are many kinds of eye movement disorders. Two common ones are Strabismus - a disorder ... in "crossed eyes" or "walleye." Nystagmus - fast, uncontrollable movements of the eyes, sometimes called "dancing eyes" Some ...

  20. About the Eye

    Medline Plus

    Full Text Available ... for Kids >> About the Eye Listen All About Vision About the Eye Ask a Scientist Video Series ... Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun ...

  1. Why Do Eyes Water?

    Science.gov (United States)

    ... for Educators Search English Español Why Do Eyes Water? KidsHealth / For Kids / Why Do Eyes Water? What's ... coming out of your nose. Why Do Eyes Water? Eyes water for lots of different reasons besides ...

  2. Fundamental Evaluation of Adaptation and Human Capabilities in a Condition Using a System to Give a User an Artificial Oculomotor Function to Control Directions of Both Eyes Independently

    Directory of Open Access Journals (Sweden)

    Fumio Mizuno

    2011-10-01

    Full Text Available To investigate flexible adaptation of visual system, we developed a system to provide a user an artificial oculomotor function to control directions of both eyes. The system named “Virtual Chameleon” consists of two CCD cameras independently controlled and a head-mounted display. The user can control each tracking directions of two cameras with sensors set to both hands so that the user can get independent arbitrary view fields for both eyes. We performed fundamental experiments to evaluate capability to evaluate adaptation to use of Virtual Chameleon and effects on the user's capabilities. Eleven healthy volunteers with normal and corrected-to-normal vision participated in the experiments. The experiments were tests to find out each position of targets put in both side of a subject. In the experiments, a condition using Virtual Chameleon and a condition without it was adopted. We obtained accuracy rates and time intervals to find out target positions as experimental results. The experiments showed all of volunteers became able to actively control independent visual axes and correctly understood two different views by using Virtual Chameleon, even though two independent view fields yielded binocular rivalry to volunteers and binocular rivalry reduced human capabilities compared to cases without Virtual Chameleon.

  3. Cerebral O2 metabolism and cerebral blood flow in humans during deep and rapid-eye-movement sleep

    DEFF Research Database (Denmark)

    Madsen, P L; Schmidt, J F; Wildschiødtz, Gordon

    1991-01-01

    on examination of this question. We have now measured CBF and CMRO2 in young healthy volunteers using the Kety-Schmidt technique with 133Xe as the inert gas. Measurements were performed during wakefulness, deep sleep (stage 3/4), and rapid-eye-movement (REM) sleep as verified by standard polysomnography...... associated with light anesthesia. During REM sleep (dream sleep) CMRO2 was practically the same as in the awake state. Changes in CBF paralleled changes in CMRO2 during both deep and REM sleep.......It could be expected that the various stages of sleep were reflected in variation of the overall level of cerebral activity and thereby in the magnitude of cerebral metabolic rate of oxygen (CMRO2) and cerebral blood flow (CBF). The elusive nature of sleep imposes major methodological restrictions...

  4. Experimental tests of a superposition hypothesis to explain the relationship between the vestibuloocular reflex and smooth pursuit during horizontal combined eye-head tracking in humans

    Science.gov (United States)

    Huebner, W. P.; Leigh, R. J.; Seidman, S. H.; Thomas, C. W.; Billian, C.; DiScenna, A. O.; Dell'Osso, L. F.

    1992-01-01

    1. We used a modeling approach to test the hypothesis that, in humans, the smooth pursuit (SP) system provides the primary signal for cancelling the vestibuloocular reflex (VOR) during combined eye-head tracking (CEHT) of a target moving smoothly in the horizontal plane. Separate models for SP and the VOR were developed. The optimal values of parameters of the two models were calculated using measured responses of four subjects to trials of SP and the visually enhanced VOR. After optimal parameter values were specified, each model generated waveforms that accurately reflected the subjects' responses to SP and vestibular stimuli. The models were then combined into a CEHT model wherein the final eye movement command signal was generated as the linear summation of the signals from the SP and VOR pathways. 2. The SP-VOR superposition hypothesis was tested using two types of CEHT stimuli, both of which involved passive rotation of subjects in a vestibular chair. The first stimulus consisted of a "chair brake" or sudden stop of the subject's head during CEHT; the visual target continued to move. The second stimulus consisted of a sudden change from the visually enhanced VOR to CEHT ("delayed target onset" paradigm); as the vestibular chair rotated past the angular position of the stationary visual stimulus, the latter started to move in synchrony with the chair. Data collected during experiments that employed these stimuli were compared quantitatively with predictions made by the CEHT model. 3. During CEHT, when the chair was suddenly and unexpectedly stopped, the eye promptly began to move in the orbit to track the moving target. Initially, gaze velocity did not completely match target velocity, however; this finally occurred approximately 100 ms after the brake onset. The model did predict the prompt onset of eye-in-orbit motion after the brake, but it did not predict that gaze velocity would initially be only approximately 70% of target velocity. One possible

  5. Trends and implications for achieving VISION 2020 human resources for eye health targets in 16 countries of sub-Saharan Africa by the year 2020.

    Science.gov (United States)

    Palmer, Jennifer J; Chinanayi, Farai; Gilbert, Alice; Pillay, Devan; Fox, Samantha; Jaggernath, Jyoti; Naidoo, Kovin; Graham, Ronnie; Patel, Daksha; Blanchet, Karl

    2014-08-15

    Development of human resources for eye health (HReH) is a major global eye health strategy to reduce the prevalence of avoidable visual impairment by the year 2020. Building on our previous analysis of current progress towards key HReH indicators and cataract surgery rates (CSRs), we predicted future indicator achievement among 16 countries of sub-Saharan Africa by 2020. Surgical and HReH data were collected from national eye care programme coordinators on six practitioner cadres: ophthalmologists, cataract surgeons, ophthalmic clinical officers, ophthalmic nurses, optometrists and 'mid-level refractionists' and combined them with publicly available population data to calculate practitioner-to-population ratios and CSRs. Data on workforce entry and exit (2008 to 2010) was used to project practitioner population and CSR growth between 2011 and 2020 in relation to projected growth in the general population. Associations between indicator progress and the presence of a non-physician cataract surgeon cadre were also explored using Wilcoxon rank sum tests and Spearman rank correlations. In our 16-country sample, practitioner per million population ratios are predicted to increase slightly for surgeons (ophthalmologists/cataract surgeons, from 3.1 in 2011 to 3.4 in 2020) and ophthalmic nurses/clinical officers (5.8 to 6.8) but remain low for refractionists (including optometrists, at 3.6 in 2011 and 2020). Among countries that have not already achieved target indicators, however, practitioner growth will be insufficient for any additional countries to reach the surgeon and refractionist targets by year 2020. Without further strategy change and investment, even after 2020, surgeon growth is only expected to sufficiently outpace general population growth to reach the target in one country. For nurses, two additional countries will achieve the target while one will fall below it. In 2011, high surgeon practitioner ratios were associated with high CSR, regardless of the type

  6. Cellular Mechanisms of Ciliary Length Control

    Directory of Open Access Journals (Sweden)

    Jacob Keeling

    2016-01-01

    Full Text Available Cilia and flagella are evolutionarily conserved, membrane-bound, microtubule-based organelles on the surface of most eukaryotic cells. They play important roles in coordinating a variety of signaling pathways during growth, development, cell mobility, and tissue homeostasis. Defects in ciliary structure or function are associated with multiple human disorders called ciliopathies. These diseases affect diverse tissues, including, but not limited to the eyes, kidneys, brain, and lungs. Many processes must be coordinated simultaneously in order to initiate ciliogenesis. These include cell cycle, vesicular trafficking, and axonemal extension. Centrioles play a central role in both cell cycle progression and ciliogenesis, making the transition between basal bodies and mitotic spindle organizers integral to both processes. The maturation of centrioles involves a functional shift from cell division toward cilium nucleation which takes place concurrently with its migration and fusion to the plasma membrane. Several proteinaceous structures of the distal appendages in mother centrioles are required for this docking process. Ciliary assembly and maintenance requires a precise balance between two indispensable processes; so called assembly and disassembly. The interplay between them determines the length of the resulting cilia. These processes require a highly conserved transport system to provide the necessary substances at the tips of the cilia and to recycle ciliary turnover products to the base using a based microtubule intraflagellar transport (IFT system. In this review; we discuss the stages of ciliogenesis as well as mechanisms controlling the lengths of assembled cilia.

  7. Development of a human corneal epithelium model utilizing a collagen vitrigel membrane and the changes of its barrier function induced by exposing eye irritant chemicals.

    Science.gov (United States)

    Takezawa, Toshiaki; Nishikawa, Kazunori; Wang, Pi-Chao

    2011-09-01

    The brief TEER (trans-epithelial electrical resistance) assay after exposing chemicals to corneal epithelium in vivo is known as a suitable method for evaluating corneal irritancy and permeability quantitatively and continuously. A collagen vitrigel membrane we previously developed is a thin (about 20 μm thick) and transparent membrane composed of high density collagen fibrils equivalent to connective tissues in vivo, e.g. corneal Bowman's membrane. To develop such a TEER assay system in vitro utilizing a human corneal epithelial model, HCE-T cells (a human corneal epithelial cell line) were cultured on the collagen vitrigel membrane substratum prepared in a Millicell chamber suitable for TEER measurement. Human corneal epithelium model possessing 5-6 cell layers sufficient for TEER assay was successfully reconstructed on the substratum in the Millicell chamber by culturing the cells in monolayer for 2 days and subsequently in air-liquid interface for 7 days. The exposure of chemicals to the model induced the time-dependent relative changes of TEER in response to the characteristic of each chemical within a few minutes. These results suggest that the TEER assay using the human corneal epithelial model is very useful for an ocular irritancy evaluation as an alternative to the Draize eye irritation test. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye Health A-Z Symptoms Glasses & Contacts Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye ... Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ...

  9. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye? Dry Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ... Inside of Your Eyelid Nov 29, 2017 New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  10. What Is Dry Eye?

    Science.gov (United States)

    ... Eye? Dry Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ... Inside of Your Eyelid Nov 29, 2017 New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  11. Investigation of the structure of human dental tissue at multiple length scales using high energy synchrotron X-ray SAXS/WAXS

    Science.gov (United States)

    Sui, Tan; Landini, Gabriel; Korsunsky, Alexander M.

    2011-10-01

    High energy (>50keV) synchrotron X-ray scattering experiments were carried out on beamline I12 JEEP at the Diamond Light Source (DLS, Oxford, UK). Although a complete human tooth could be studied, in the present study attention was focused on coupons from the region of the Dentin-Enamel Junction (DEJ). Simultaneous high energy SAXS/WAXS measurements were carried out. Quantitative analysis of the results allows multiple length scale characterization of the nano-crystalline structure of dental tissues. SAXS patterns analysis provide insight into the mean thickness and orientation of hydroxyapatite particles, while WAXS (XRD) patterns allow the determination of the crystallographic unit cell parameters of the hydroxyapatite phase. It was found that the average particle thickness determined from SAXS interpretation varies as a function of position in the vicinity of the DEJ. Most mineral particles are randomly orientated within dentin, although preferred orientation emerges and becomes stronger on approach to the enamel. Within the enamel, texture is stronger than anywhere in the dentin, and the determination of lattice parameters can be accomplished by Pawley refinement of the multiple peak diffraction pattern. The results demonstrate the feasibility of using high energy synchrotron X-ray beams for the characterization of human dental tissues. This opens up the opportunity of studying thick samples (e.g., complete teeth) in complex sample environments (e.g., under saline solution). This opens new avenues for the application of high energy synchrotron X-ray scattering to dental research.

  12. Characterization of the cloned full-length and a truncated human target of rapamycin: Activity, specificity, and enzyme inhibition as studied by a high capacity assay

    International Nuclear Information System (INIS)

    Toral-Barza, Lourdes; Zhang Weiguo; Lamison, Craig; LaRocque, James; Gibbons, James; Yu, Ker

    2005-01-01

    The mammalian target of rapamycin (mTOR/TOR) is implicated in cancer and other human disorders and thus an important target for therapeutic intervention. To study human TOR in vitro, we have produced in large scale both the full-length TOR (289 kDa) and a truncated TOR (132 kDa) from HEK293 cells. Both enzymes demonstrated a robust and specific catalytic activity towards the physiological substrate proteins, p70 S6 ribosomal protein kinase 1 (p70S6K1) and eIF4E binding protein 1 (4EBP1), as measured by phosphor-specific antibodies in Western blotting. We developed a high capacity dissociation-enhanced lanthanide fluorescence immunoassay (DELFIA) for analysis of kinetic parameters. The Michaelis constant (K m ) values of TOR for ATP and the His6-S6K substrate were shown to be 50 and 0.8 μM, respectively. Dose-response and inhibition mechanisms of several known inhibitors, the rapamycin-FKBP12 complex, wortmannin and LY294002, were also studied in DELFIA. Our data indicate that TOR exhibits kinetic features of those shared by traditional serine/threonine kinases and demonstrate the feasibility for TOR enzyme screen in searching for new inhibitors

  13. NetMHC-3.0: accurate web accessible predictions of human, mouse and monkey MHC class I affinities for peptides of length 8-11.

    Science.gov (United States)

    Lundegaard, Claus; Lamberth, Kasper; Harndahl, Mikkel; Buus, Søren; Lund, Ole; Nielsen, Morten

    2008-07-01

    NetMHC-3.0 is trained on a large number of quantitative peptide data using both affinity data from the Immune Epitope Database and Analysis Resource (IEDB) and elution data from SYFPEITHI. The method generates high-accuracy predictions of major histocompatibility complex (MHC): peptide binding. The predictions are based on artificial neural networks trained on data from 55 MHC alleles (43 Human and 12 non-human), and position-specific scoring matrices (PSSMs) for additional 67 HLA alleles. As only the MHC class I prediction server is available, predictions are possible for peptides of length 8-11 for all 122 alleles. artificial neural network predictions are given as actual IC(50) values whereas PSSM predictions are given as a log-odds likelihood scores. The output is optionally available as download for easy post-processing. The training method underlying the server is the best available, and has been used to predict possible MHC-binding peptides in a series of pathogen viral proteomes including SARS, Influenza and HIV, resulting in an average of 75-80% confirmed MHC binders. Here, the performance is further validated and benchmarked using a large set of newly published affinity data, non-redundant to the training set. The server is free of use and available at: http://www.cbs.dtu.dk/services/NetMHC.

  14. Altered aquaporin expression in glaucoma eyes

    DEFF Research Database (Denmark)

    Tran, Thuy Linh; Bek, Toke; Cour, Morten la

    2014-01-01

    Aquaporins (AQP) are channels in the cell membrane that mainly facilitate a passive transport of water. In the eye, AQPs are expressed in the ciliary body and retina and may contribute to the pathogenesis of glaucoma and optic neuropathy. We investigated the expression of AQP1, AQP3, AQP4, AQP5......, AQP7 and AQP9 in human glaucoma eyes compared with normal eyes. Nine glaucoma eyes were examined. Of these, three eyes were diagnosed with primary open angle glaucoma; three eyes had neovascular glaucoma; and three eyes had chronic angle-closure glaucoma. Six eyes with normal intraocular pressure...... and without glaucoma were used as control. Immunohistochemistry was performed using antibodies against AQP1, AQP3, AQP4, AQP5, AQP7 and AQP9. For each specimen, optical densities of immunoprecipitates were measured using Photoshop and the staining intensities were calculated. Immunostaining showed labelling...

  15. Bona fide colour: DNA prediction of human eye and hair colour from ancient and contemporary skeletal remains

    NARCIS (Netherlands)

    J. Draus-Barini (Jolanta); S. Walsh (Susan); E. Pośpiech (Ewelina); T. Kupiec (Tomasz); H. Głab (Henryk); W. Branicki (Wojciech); M.H. Kayser (Manfred)

    2013-01-01

    textabstractBackground: DNA analysis of ancient skeletal remains is invaluable in evolutionary biology for exploring the history of species, including humans. Contemporary human bones and teeth, however, are relevant in forensic DNA analyses that deal with the identification of perpetrators, missing

  16. Mapping of the human APOB gene to chromosome 2p and demonstration of a two-allele restriction fragment length polymorphism

    International Nuclear Information System (INIS)

    Huang, L.; Miller, D.A.; Bruns, G.A.P.; Breslow, J.L.

    1986-01-01

    ApoB is a large glycoprotein with an apparent molecular mass of 550 kDa on NaDodSO 4 /PAGE. Recently, apoB cDNA clones have been isolated from an expression library made with mRNA from a human hepatoma cell line. These clones, which were all 1.5-1.6 kilobases (kb) long and corresponded to the 3' end of apoB mRNA, were used to demonstrate that hepatic apoB mRNA is ≅ 22 kb long. In the current report, a probe derived from one of these cDNA clones, pB8, was used for in situ hybridization experiments to map the human gene for apoB, APOB, to the distal half of the short arm of chromosome 2. This probe was also used to analyze somatic cell hybrids and, in agreement with the in situ hybridization studies, concordancy was demonstrated with chromosome 2. In addition, two hybrids with chromosome 2 translocations that contain only the short arm reacted with the pB8 probe. A third hybrid with a complex rearrangement of chromosome 2, which deleted an interstitial region and the tip of the short arm of chromosome 2, did not react. These data indicate that APOB maps to either 2p21-p23 or 2p24-pter. In further studies, DNA from normal individuals, digested with the restriction endonuclease EcoRI and subjected to Southern blot analysis with the pB8 probe, revealed a two-allele restriction fragment length polymorphism (RFLP). The mapping studies provide the means for understanding the relationship of the APOB locus to others in the human genome, whereas the demonstration of an APOB RFLP increases their ability to assess the role of this locus in determining plasma lipoprotein levels

  17. Allelic sequence variations in the hypervariable region of a T-cell receptor β chain: Correlation with restriction fragment length polymorphism in human families and populations

    International Nuclear Information System (INIS)

    Robinson, M.A.

    1989-01-01

    Direct sequence analysis of the human T-cell antigen receptor (TCR) V β1 variable gene identified a single base-pair allelic variation (C/G) located within the coding region. This change results in substitution of a histidine (CAC) for a glutamine (CAG) at position 48 of the TCR β chain, a position predicted to be in the TCR antigen binding site. The V β1 polymorphism was found by DNA sequence analysis of V β1 genes from seven unrelated individuals; V β1 genes were amplified by the polymerase chain reaction, the amplified fragments were cloned into M13 phage vectors, and sequences were determined. To determined the inheritance patterns of the V β1 substitution and to test correlation with V β1 restriction fragment length polymorphism detected with Pvu II and Taq I, allele-specific oligonucleotides were constructed and used to characterize amplified DNA samples. Seventy unrelated individuals and six families were tested for both restriction fragment length polymorphism and for the V β1 substitution. The correlation was also tested using amplified, size-selected, Pvu II- and Taq I-digested DNA samples from heterozygotes. Pvu II allele 1 (61/70) and Taq I allele 1 (66/70) were found to be correlated with the substitution giving rise to a histidine at position 48. Because there are exceptions to the correlation, the use of specific probes to characterize allelic forms of TCR variable genes will provide important tools for studies of basic TCR genetics and disease associations

  18. Identification of intracellular phospholipases A2 in the human eye: involvement in phagocytosis of photoreceptor outer segments

    DEFF Research Database (Denmark)

    Kolko, Miriam; Wang, Jinmei; Zhan, Chen

    2007-01-01

    PURPOSE: To identify intracellular phospholipases A(2) (PLA(2)) in the human retina and to explore the role of these enzymes in human retinal pigment epithelium (RPE) phagocytosis of photoreceptor outer segments (POS). METHODS: PCR amplification and Western blot analysis were used to identify m......)-VIA activity was found to be specifically increased 12 hours after ARPE-19 cells were fed with POS. Finally, RPE phagocytosis was inhibited by the iPLA(2)-VIA inhibitor bromoenol lactone. CONCLUSIONS: Various intracellular PLA(2) subtypes are present in the human retina. iPLA(2)-VIA may play...

  19. Eye Contricks

    Directory of Open Access Journals (Sweden)

    N Wade

    2011-04-01

    Full Text Available Icons are eye-cons: they provide a distillation of a complex object or idea into a simple pictorial shape. They create the impression of representing that which cannot be presented. Even at the level of the photograph, the links between icon and object are tenuous. The dimension of distance or depth is missing from the icon, and this alone introduces all manner of potential ambiguities. The history of art can be considered as an exploration of the missing link between icon and object. Eye-cons are more honest—they are tricks of vision so that what is seen does not necessarily correspond to what is presented. They are visual allusions rather than visual illusions, although they can display illusory effects. At its broadest, icon can be equated with image. The concept of image has thrived on its vagueness, and so attempts have been made to refine it. An icon corresponds to an optical image: it shares some of the projective characteristics of the object represented. Written words are also icons but they do not resemble the objects they represent—they are stylised or conventional rather than spatialised and projective. Words and images were set in delightful opposition by René Magritte (1898-1967 in a series of pipe paintings, and he also played on the theme of the arbitrariness of the verbal labels assigned to objects. What is surprising is that Magritte did not apply his painterly skills to transforming the word shapes he used. A similar reluctance to transform the typefaces pervades visual poetry. My interests are in the visual rather than the poetic dimension, and I will present a range of my own eye contricks which play with letter and word shapes in a variety of ways.

  20. The socioeconomic impact of human immunodeficiency virus / acquired immune deficiency syndrome in India and its relevance to eye care

    OpenAIRE

    Murthy GVS

    2008-01-01

    Human immunodeficiency virus (HIV) infection is aptly called the modern day ′plague′ and has the potential to decimate people in the productive age group. On the other hand, the increasing life expectancy in developing countries spirals age-related blindness. One therefore reduces economic productivity while the other increases economic dependency. Both lead to increased expenditure of households though in different proportions. Human immunodeficiency virus and blindness are bot...

  1. Modelling the impact of blood flow on the temperature distribution in the human eye and the orbit: fixed heat transfer coefficients versus the Pennes bioheat model versus discrete blood vessels

    Energy Technology Data Exchange (ETDEWEB)

    Flyckt, V M M; Raaymakers, B W; Lagendijk, J J W [Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht (Netherlands)

    2006-10-07

    Prediction of the temperature distribution in the eye depends on how the impact of the blood flow is taken into account. Three methods will be compared: a simplified eye anatomy that applies a single heat transfer coefficient to describe all heat transport mechanisms between the sclera and the body core, a detailed eye anatomy in which the blood flow is accounted for either by the bioheat approach, or by including the discrete vasculature in the eye and the orbit. The comparison is done both for rabbit and human anatomies, normo-thermally and when exposed to homogeneous power densities. The first simplified model predicts much higher temperatures than the latter two. It was shown that the eye is very hard to heat when taking physiological perfusion correctly into account. It was concluded that the heat transfer coefficient describing the heat transport from the sclera to the body core reported in the literature for the first simplified model is too low. The bioheat approach is appropriate for a first-order approximation of the temperature distribution in the eye when exposed to a homogeneous power density, but the discrete vasculature down to 0.2 mm in diameter needs to be taken into account when the heterogeneity of the temperature distribution at a mm scale is of interest.

  2. Modelling the impact of blood flow on the temperature distribution in the human eye and the orbit: fixed heat transfer coefficients versus the Pennes bioheat model versus discrete blood vessels

    International Nuclear Information System (INIS)

    Flyckt, V M M; Raaymakers, B W; Lagendijk, J J W

    2006-01-01

    Prediction of the temperature distribution in the eye depends on how the impact of the blood flow is taken into account. Three methods will be compared: a simplified eye anatomy that applies a single heat transfer coefficient to describe all heat transport mechanisms between the sclera and the body core, a detailed eye anatomy in which the blood flow is accounted for either by the bioheat approach, or by including the discrete vasculature in the eye and the orbit. The comparison is done both for rabbit and human anatomies, normo-thermally and when exposed to homogeneous power densities. The first simplified model predicts much higher temperatures than the latter two. It was shown that the eye is very hard to heat when taking physiological perfusion correctly into account. It was concluded that the heat transfer coefficient describing the heat transport from the sclera to the body core reported in the literature for the first simplified model is too low. The bioheat approach is appropriate for a first-order approximation of the temperature distribution in the eye when exposed to a homogeneous power density, but the discrete vasculature down to 0.2 mm in diameter needs to be taken into account when the heterogeneity of the temperature distribution at a mm scale is of interest

  3. Different schematic eyes and their accuracy to the in vivo eye: a quantitative comparison study

    OpenAIRE

    Almeida, Marina Storani de; Carvalho, Luis Alberto

    2007-01-01

    Current ophthalmic technology allows the manipulation of eye components, such as anterior cornea and lens, of the human eye with a considerable precision and customization. This technology opens up the possibility of exploiting some characteristics of the eye in order to improve the methods of correcting optical aberrations. Moreover, product development and research for the eye-care professional has reached very high standards, since there is nowadays software available to design and simulat...

  4. Molecular analysis of Leptospira spp. isolated from humans by restriction fragment length polymorphism, real-time PCR and pulsed-field gel electrophoresis.

    Science.gov (United States)

    Turk, Nenad; Milas, Zoran; Mojcec, Vesna; Ruzic-Sabljic, Eva; Staresina, Vilim; Stritof, Zrinka; Habus, Josipa; Postic, Daniele

    2009-11-01

    A total of 17 Leptospira clinical strains isolated from humans in Croatia were serologically and genetically analysed. For serovar identification, the microscopic agglutination test (MAT) and pulsed-field gel electrophoresis (PFGE) were used. To identify isolates on genomic species level, PCR-based restriction fragment length polymorphism (RFLP) and real-time PCR were performed. MAT revealed the following serogroup affinities: Grippotyphosa (seven isolates), Icterohaemorrhagiae (eight isolates) and Javanica (two isolates). RFLP of PCR products from a 331-bp-long fragment of rrs (16S rRNA gene) digested with endonucleases MnlI and DdeI and real-time PCR revealed three Leptospira genomic species. Grippotyphosa isolates belonged to Leptospira kirschneri, Icterohaemorrhagiae isolates to Leptospira interrogans and Javanica isolates to Leptospira borgpetersenii. Genomic DNA from 17 leptospiral isolates was digested with NotI and SgrAI restriction enzymes and analysed by PFGE. Results showed that seven isolates have the same binding pattern to serovar Grippotyphosa, eight isolates to serovar Icterohaemorrhagiae and two isolates to serovar Poi. Results demonstrate the diversity of leptospires circulating in Croatia. We point out the usefulness of a combination of PFGE, RFLP and real-time PCR as appropriate molecular methods in molecular analysis of leptospires.

  5. Pst I restriction fragment length polymorphism of human placental alkaline phosphatase gene: Mendelian in segregation and localization of mutation site in the gene

    International Nuclear Information System (INIS)

    Tsavaler, L.; Penhallow, R.C.; Sussman, H.H.

    1988-01-01

    The pattern of inheritance of a Pst I restriction fragment length polymorphism (RFLP) of the human placental alkaline phosphatase gene was studied in nine nuclear families by Southern blot hybridization analysis of genomic DNA. The dimorphic RFLP is defined by the presence of allelic fragments 1.0 kilobase and 0.8 kilobase long. The results of this study show that the two alleles of the Pst I RFLP of the placental alkaline phosphatase gene segregate as codominant traits according to Mendelian expectations. For a polymorphism to be useful as a genetic marker the probability that an offspring is informative (PIC) must be at least 0.15. The allelic frequency of the 1.0-kilobase allele is 0.21, which correlates to a probability that an offspring is informative of 0.275 and is indicative of a useful polymorphism. By using probes derived from different regions of the placental alkaline phosphatase cDNA, the mutated Pst I site causing the RFLP was located in the penultimate intron 2497 base pairs downstream from the transcriptional initiation site

  6. Use of a finite element model of heat transport in the human eye to predict time of death.

    Science.gov (United States)

    Smart, Jimmy L; Kaliszan, Michal

    2013-01-01

    The goal of this work was to compare human temperature decay curves generated from execution of a COMSOL Multiphysics(®) finite element software model with that of experimental postmortem temperature decay curves. Experiments were performed in 10 human cadavers. The postmortem temperature was continuously measured in human eyeballs and rectums from c. 3 h up to 15 h postmortem. Model-generated curves reflected experimental curves for 10 cases with coefficients of determination ranging from 0.9448 to 0.9953. From modeling efforts, normalized temperature decay curves were generated to aid first responders to estimate time of death within the early postmortem period of 0-24 h. This proposed model has advantages over other models in that it is applied to the human eyeball, where temperature plateau effects are minimal to nonexistent. Nevertheless, the proposed model can be adjusted to compensate for any temperature plateau effects that do exist. It also can take account of antemortem hyperthermia conditions that are known to have occurred. The current model only applies to natural environmental conditions, with no forced convection, no direct sunlight, immersion in water, or other unusual conditions. © 2012 American Academy of Forensic Sciences.

  7. The prediction of spherical aberration with schematic eyes.

    Science.gov (United States)

    Liou, H L; Brennan, N A

    1996-07-01

    Many model eyes have been proposed; they differ in optical characteristics and therefore have different aberrations and image quality. In predicting the visual performance of the eye, we are most concerned with the central foveal vision. Spherical aberration is the only on-axis monochromatic aberration and can be used as a criterion to assess the degree of resemblance of eye models to the human eye. We reviewed and compiled experimental values of the spherical aberration of the eye, calculated the spherical aberration of several different categories of model eyes and compared the calculated results to the experimental data. Results show an over-estimation of spherical aberration by all models, the finite schematic eyes predicting values of spherical aberration closest to the experimental data. Current model eyes do not predict the average experimental values of the spherical aberration of the eye. A new model eye satisfying this assessment criterion is required for investigations of the visual performance of the eye.

  8. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye Health / Eye Health A-Z Dry Eye ... Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué es el ojo seco? Written By: Kierstan ...

  9. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ... Your Eyelid Nov 29, 2017 New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  10. Bags Under Eyes

    Science.gov (United States)

    Bags under eyes Overview Bags under eyes — mild swelling or puffiness under the eyes — are common as you age. With aging, the tissues around your ... space below your eyes, adding to the swelling. Bags under eyes are usually a cosmetic concern and ...

  11. About the Eye

    Medline Plus

    Full Text Available ... Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun Stuff Cool Eye Tricks Links to More Information Optical Illusions Printables About the Eye Your eyes ...

  12. The socioeconomic impact of human immunodeficiency virus / acquired immune deficiency syndrome in India and its relevance to eye care.

    Science.gov (United States)

    Murthy, Gvs

    2008-01-01

    Human immunodeficiency virus (HIV) infection is aptly called the modern day 'plague' and has the potential to decimate people in the productive age group. On the other hand, the increasing life expectancy in developing countries spirals age-related blindness. One therefore reduces economic productivity while the other increases economic dependency. Both lead to increased expenditure of households though in different proportions. Human immunodeficiency virus and blindness are both associated with discrimination, stigma and long-term consequences. They impact the socioeconomic fabric of the affected individuals, communities and countries. The loss in productivity and the cost of support to the affected individuals are seen in both. Each is a potent problem on its own but together they spell disaster in geometric proportions rather than a simple additive effect. Strategies need to be evolved to provide solace and improve the quality of life of an HIV-positive blind individual.

  13. The socioeconomic impact of human immunodeficiency virus / acquired immune deficiency syndrome in India and its relevance to eye care

    Directory of Open Access Journals (Sweden)

    Murthy GVS

    2008-01-01

    Full Text Available Human immunodeficiency virus (HIV infection is aptly called the modern day ′plague′ and has the potential to decimate people in the productive age group. On the other hand, the increasing life expectancy in developing countries spirals age-related blindness. One therefore reduces economic productivity while the other increases economic dependency. Both lead to increased expenditure of households though in different proportions. Human immunodeficiency virus and blindness are both associated with discrimination, stigma and long-term consequences. They impact the socioeconomic fabric of the affected individuals, communities and countries. The loss in productivity and the cost of support to the affected individuals are seen in both. Each is a potent problem on its own but together they spell disaster in geometric proportions rather than a simple additive effect. Strategies need to be evolved to provide solace and improve the quality of life of an HIV-positive blind individual.

  14. The immune privilege of the eye: human retinal pigment epithelial cells selectively modulate T-cell activation in vitro

    DEFF Research Database (Denmark)

    Kaestel, Charlotte G; Lovato, Paola; Ødum, Niels

    2005-01-01

    PURPOSE: To examine the effect of human retinal pigment epithelial (RPE) cells on phytohemagglutinin (PHA) activation of T cells. METHODS: Resting peripheral blood lymphocytes (PBLs) were stimulated with PHA with or without the presence of gamma-irradiated RPE cells. Proliferation and the cell...... in cell culture supernatant was measured by ELISA. RESULTS: Human RPE cells were found to suppress PHA-induced proliferation, cyclin A, IL-2R-alpha and -gamma, and CD71 expression and decrease the production of IL-2; but RPE cells do not inhibit the PHA-induced expression of early activation markers CD69......, MHC class I and II, and of cyclin D of the PBLs. CONCLUSIONS: These results are the first to indicate that RPE cells impede generation of activated T cells by interfering with the induction of high-affinity IL-2R-alphabetagamma, IL-2 production, and the expression of CD71 and cyclin A....

  15. About the Eye

    Medline Plus

    Full Text Available ... your eye. It helps your eye focus light so things look sharp and clear. Sclera (SKLEH-ruh) ... the different parts of your eye work together so you can see and make sense of the ...

  16. About the Eye

    Medline Plus

    Full Text Available ... Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision ... to More Information Optical Illusions Printables About the Eye Your eyes are made up of many different ...

  17. Fluorescein eye stain

    Science.gov (United States)

    Abnormal results may point to: Abnormal tear production (dry eye) Blocked tear duct Corneal abrasion (a scratch on ... object in eye ) Infection Injury or trauma Severe dry eye associated with arthritis (keratoconjunctivitis sicca)

  18. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Member Services Advocacy Foundation About Subspecialties & More Eye Health Home Annual Meeting Clinical Education Practice Management Member ... Center Redmond Ethics Center Global Ophthalmology Guide Eye Health Find an Ophthalmologist Academy Store Eye Health A- ...

  19. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Ophthalmology/Strabismus Ocular Pathology/Oncology Oculoplastics/Orbit Refractive Management/Intervention Retina/Vitreous Uveitis Focus On ... Dry Eye Sections What Is Dry Eye? Dry Eye Symptoms Causes of ...

  20. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Dry Eye Symptoms Related Ask an Ophthalmologist Answers Can a six-month dissolvable punctal plug be removed ... my eyes dry after LASIK? Jun 19, 2016 Can I be tested whether I close my eyes ...

  1. Eye Injuries at Work

    Science.gov (United States)

    ... National Standards Institute (ANSI) to meet their eye protection standards. If an eye injury occurs, see an ophthalmologist or go to the emergency room immediately, even if the eye injury appears minor. Delaying medical attention can result in permanent vision ...

  2. Effect of the electrostatic surface potential on the oligomerization of full-length human recombinant prion protein at single-molecule level

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Bin; Xu, Bingqian, E-mail: bxu@engr.uga.edu [Single Molecule Study Laboratory, College of Engineering and Nanoscale Science, and Engineering Center, University of Georgia, Athens, Georgia 30605 (United States); Lou, Zhichao [Single Molecule Study Laboratory, College of Engineering and Nanoscale Science, and Engineering Center, University of Georgia, Athens, Georgia 30605 (United States); College of Materials Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing 210016 (China); Zhang, Haiqian [College of Materials Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing 210016 (China)

    2016-03-21

    The electrostatic surface potential (ESP) of prion oligomers has critical influences on the aggregating processes of the prion molecules. The atomic force microscopy (AFM) and structural simulation were combined to investigate the molecular basis of the full-length human recombinant prion oligomerization on mica surfaces. The high resolution non-intrusive AFM images showed that the prion oligomers formed different patterns on mica surfaces at different buffer pH values. The basic binding units for the large oligomers were determined to be prion momoners (Ms), dimers (Ds), and trimers (Ts). The forming of the D and T units happened through the binding of hydrophobic β-sheets of the M units. In contrast, the α-helices of these M, D, and T units were the binding areas for the formation of large oligomers. At pH 4.5, the binding units M, D, and T showed clear polarized ESP distributions on the surface domains, while at pH 7.0, they showed more evenly distributed ESPs. Based on the conformations of oligomers observed from AFM images, the D and T units were more abundantly on mica surface at pH 4.5 because the ESP re-distribution of M units helped to stabilize these larger oligomers. The amino acid side chains involved in the binding interfaces were stabilized by hydrogen bonds and electrostatic interactions. The detailed analysis of the charged side chains at pH 4.5 indicated that the polarized ESPs induced the aggregations among M, D, and T to form larger oligomers. Therefore, the hydrogen bonds and electrostatic interactions worked together to form the stabilized prion oligomers.

  3. Effect of the electrostatic surface potential on the oligomerization of full-length human recombinant prion protein at single-molecule level

    International Nuclear Information System (INIS)

    Wang, Bin; Xu, Bingqian; Lou, Zhichao; Zhang, Haiqian

    2016-01-01

    The electrostatic surface potential (ESP) of prion oligomers has critical influences on the aggregating processes of the prion molecules. The atomic force microscopy (AFM) and structural simulation were combined to investigate the molecular basis of the full-length human recombinant prion oligomerization on mica surfaces. The high resolution non-intrusive AFM images showed that the prion oligomers formed different patterns on mica surfaces at different buffer pH values. The basic binding units for the large oligomers were determined to be prion momoners (Ms), dimers (Ds), and trimers (Ts). The forming of the D and T units happened through the binding of hydrophobic β-sheets of the M units. In contrast, the α-helices of these M, D, and T units were the binding areas for the formation of large oligomers. At pH 4.5, the binding units M, D, and T showed clear polarized ESP distributions on the surface domains, while at pH 7.0, they showed more evenly distributed ESPs. Based on the conformations of oligomers observed from AFM images, the D and T units were more abundantly on mica surface at pH 4.5 because the ESP re-distribution of M units helped to stabilize these larger oligomers. The amino acid side chains involved in the binding interfaces were stabilized by hydrogen bonds and electrostatic interactions. The detailed analysis of the charged side chains at pH 4.5 indicated that the polarized ESPs induced the aggregations among M, D, and T to form larger oligomers. Therefore, the hydrogen bonds and electrostatic interactions worked together to form the stabilized prion oligomers.

  4. Effect of the electrostatic surface potential on the oligomerization of full-length human recombinant prion protein at single-molecule level

    Science.gov (United States)

    Wang, Bin; Lou, Zhichao; Zhang, Haiqian; Xu, Bingqian

    2016-03-01

    The electrostatic surface potential (ESP) of prion oligomers has critical influences on the aggregating processes of the prion molecules. The atomic force microscopy (AFM) and structural simulation were combined to investigate the molecular basis of the full-length human recombinant prion oligomerization on mica surfaces. The high resolution non-intrusive AFM images showed that the prion oligomers formed different patterns on mica surfaces at different buffer pH values. The basic binding units for the large oligomers were determined to be prion momoners (Ms), dimers (Ds), and trimers (Ts). The forming of the D and T units happened through the binding of hydrophobic β-sheets of the M units. In contrast, the α-helices of these M, D, and T units were the binding areas for the formation of large oligomers. At pH 4.5, the binding units M, D, and T showed clear polarized ESP distributions on the surface domains, while at pH 7.0, they showed more evenly distributed ESPs. Based on the conformations of oligomers observed from AFM images, the D and T units were more abundantly on mica surface at pH 4.5 because the ESP re-distribution of M units helped to stabilize these larger oligomers. The amino acid side chains involved in the binding interfaces were stabilized by hydrogen bonds and electrostatic interactions. The detailed analysis of the charged side chains at pH 4.5 indicated that the polarized ESPs induced the aggregations among M, D, and T to form larger oligomers. Therefore, the hydrogen bonds and electrostatic interactions worked together to form the stabilized prion oligomers.

  5. Safety of PEGylated recombinant human full-length coagulation factor VIII (BAX 855) in the overall context of PEG and PEG conjugates.

    Science.gov (United States)

    Stidl, R; Fuchs, S; Bossard, M; Siekmann, J; Turecek, P L; Putz, M

    2016-01-01

    BAX 855 is a PEGylated human full-length recombinant factor VIII (rFVIII) based on licensed rFVIII (ADVATE). The applied PEGylation technology has been optimized to retain functionality of the FVIII molecule, improve its pharmacokinetic properties and allow less frequent injections while maintaining efficacy. The aim of this study was to confirm that the excellent safety profile of ADVATE remains unchanged after PEGylation. Non-clinical safety studies with BAX 855 and its respective unbound polyethylene glycol (PEG) were conducted in several species. The distribution of a single dose of radiolabelled BAX 855 was further investigated in rats. Publically available safety data on PEG alone and PEGylated biomolecules were summarized and reviewed for specific safety findings attributable to PEG or PEGylated biopharmaceuticals. Safety pharmacology studies in rabbits and macaques and repeated dose toxicity studies in rats and macaques identified no safety issues. Results of a distribution study in rats administered radiolabelled BAX 855 showed that radioactivity was completely excreted; urine was the major elimination route. A 28-day study in rats dosed with the unbound PEG constituent (PEG2ru20KCOOH) of BAX 855 showed no adverse or non-adverse effects. Safety data for PEG and PEG-protein conjugates indicate no safety concerns associated with PEG at clinically relevant dose levels. Although vacuolation of certain cell types has been reported in mammals, no such vacuolation was observed with BAX 855 or with the unbound PEG constituent. Non-clinical safety evaluation of PEG and BAX 855 identified no safety signals; the compound is now in clinical development for the treatment of patients with haemophilia A. © 2015 Baxalta Innovations GmbH. Haemophilia Published by John Wiley & Sons Ltd.

  6. Eye Care Professionals' Perspectives on Eye Donation and an Eye Donation Registry for Research: A Single-Institution, Cross-Sectional Study.

    Science.gov (United States)

    Williams, Andrew M; Allingham, R Rand; Stamer, W Daniel; Muir, Kelly W

    2016-06-01

    A centralized eye donation registry for research could help to bridge the gap between patients interested in donating their eyes to science and scientists who conduct research on human eye tissue. Previous research has demonstrated patient and family support for such a registry. In this study, we assessed the views that eye care professionals have toward an eye donation registry for research. Surveys were distributed to all 46 clinical faculty members of the Duke University Eye Center. In addition to collecting demographic information, the surveys assessed clinicians' experience with discussing eye donation with patients, described the proposed eye donation registry for research and asked how the registry would affect the clinicians' practice. A total of 21 eye care professionals returned the survey. Thirty-three percent reported discussing eye donation with patients, and 43% reported that a patient has asked about donating their eyes for research on their disease. Eighty-six percent of eye care professionals reported that a centralized registry would improve the way they work with patients who express a desire to donate their eyes for research. The majority of eye care professionals at our academic institution indicated that an eye donation registry for research would improve how they work with patients who are interested in donating their eyes for research on their disease. Future research should examine how best to communicate this registry to ophthalmic patients.

  7. Comparative analysis of human cytomegalovirus a-sequence in multiple clinical isolates by using polymerase chain reaction and restriction fragment length polymorphism assays.

    Science.gov (United States)

    Zaia, J A; Gallez-Hawkins, G; Churchill, M A; Morton-Blackshere, A; Pande, H; Adler, S P; Schmidt, G M; Forman, S J

    1990-01-01

    The human cytomegalovirus (HCMV) a-sequence (a-seq) is located in the joining region between the long (L) and short (S) unique sequences of the virus (L-S junction), and this hypervariable junction has been used to differentiate HCMV strains. The purpose of this study was to investigate whether there are differences among strains of human cytomegalovirus which could be characterized by polymerase chain reaction (PCR) amplification of the a-seq of HCMV DNA and to compare a PCR method of strain differentiation with conventional restriction fragment length polymorphism (RFLP) methodology by using HCMV junction probes. Laboratory strains of HCMV and viral isolates from individuals with HCMV infection were characterized by using both RFLPs and PCR. The PCR assay amplified regions in the major immediate-early gene (IE-1), the 64/65-kDa matrix phosphoprotein (pp65), and the a-seq of the L-S junction region. HCMV laboratory strains Towne, AD169, and Davis were distinguishable, in terms of size of the amplified product, when analyzed by PCR with primers specific for the a-seq but were indistinguishable by using PCR targeted to IE-1 and pp65 sequences. When this technique was applied to a characterization of isolates from individuals with HCMV infection, selected isolates could be readily distinguished. In addition, when the a-seq PCR product was analyzed with restriction enzyme digestion for the presence of specific sequences, these DNA differences were confirmed. PCR analysis across the variable a-seq of HCMV demonstrated differences among strains which were confirmed by RFLP in 38 of 40 isolates analyzed. The most informative restriction enzyme sites in the a-seq for distinguishing HCMV isolates were those of MnlI and BssHII. This indicates that the a-seq of HCMV is heterogeneous among wild strains, and PCR of the a-seq of HCMV is a practical way to characterize differences in strains of HCMV. Images PMID:1980680

  8. Spectral interferometric length measurement and tomography

    International Nuclear Information System (INIS)

    Pinkl, W.

    1998-01-01

    This work presents a new method for optical length measurement using the principles of spectral interferometry. Results of thickness measurements on glass plates, the human cornea in vivo and human finger and toe nails in vivo and in vitro are discussed. It could be demonstrated that the absorption coefficient of red and green ink can be measured depth sensitive. Another chapter describes a new technique to measure a thickness profile of a sample within the illuminating beam. It could be demonstrated that a thickness profile over a distance of a few millimeters can be measured with one single measurement. At the Institute of Medical Physics of the University of Vienna a method to measure intraocular distances by the means of interferometry has been developed during the last ten years. Basing on this method (dual beam interferometry) an optical in vivo tomography experiment could be established. A thickness map of the retina of a human eye in vivo can be easily measured. The dual beam technique uses a Michelson interferometer with a moving mirror to adjust the length of the interferometer arms. The mirror is moved by a stepper motor. This movement induces vibrations, misalignment and other disadvantages. So mechanically moved parts as reasons for possible errors should be eliminated. This work shows one possible solution - using the principle of spectral interferometry. A spectral interferometry experiment is a static experiment, no moving parts are used. A spectral interferometry experiment has been used to measure the thickness of glass plates and stacks of glass plates. Using two light sources of different wavelengths spectral absorption properties of a sample can be measured depth sensitive. This could be demonstrated with stacks of glass plates and the use of red and green ink between two plates. The obtained results are compared to the results of a computer simulation. To demonstrate the ability of spectral interferometry to measure the thickness of biologic

  9. Retinal and post-retinal contributions to the Quantum efficiency of the human eye revealed by electrical neuroimaging

    Directory of Open Access Journals (Sweden)

    Gibran eManasseh

    2013-11-01

    Full Text Available The retina is one of the best known quantum detectors with rods able to reliably respond to single photons. However, estimates on the number of photons eliciting conscious perception, based on signal detection theory, are systematically above these values after discounting by retinal losses. One possibility is that there is a trade-off between the limited motor resources available to living systems and the excellent reliability of the visual photoreceptors. On this view, the limits to sensory thresholds are not set by the individual reliability of the receptors within each sensory modality (as often assumed but rather by the limited central processing and motor resources available to process the constant inflow of sensory information. To investigate this issue, we reproduced the classical experiment from Hetch aimed to determine the sensory threshold in human vision. We combined a careful physical control of the stimulus parameters with high temporal/spatial resolution recordings of EEG signals and behavioral variables over a relatively large sample of subjects (12. Contrarily to the idea that the limits to visual sensitivity are fully set by the statistical fluctuations in photon absorption on retinal photoreceptors we observed that the state of ongoing neural oscillations before any photon impinges the retina helps to determine if the responses of photoreceptors have access to central conscious processing. Our results suggest that motivational and attentional off-retinal mechanisms play a major role in reducing the QE efficiency of the human visual system when compared to the efficiency of isolated retinal photoreceptors. Yet, this mechanism might subserve adaptive behavior by enhancing the overall multisensory efficiency of the whole system composed by diverse reliable sensory modalities.

  10. Interaction vs. observation: distinctive modes of social cognition in human brain and behavior? A combined fMRI and eye-tracking study.

    Science.gov (United States)

    Tylén, Kristian; Allen, Micah; Hunter, Bjørk K; Roepstorff, Andreas

    2012-01-01

    Human cognition has usually been approached on the level of individual minds and brains, but social interaction is a challenging case. Is it best thought of as a self-contained individual cognitive process aiming at an "understanding of the other," or should it rather be approached as an collective, inter-personal process where individual cognitive components interact on a moment-to-moment basis to form coupled dynamics? In a combined fMRI and eye-tracking study we directly contrasted these models of social cognition. We found that the perception of situations affording social contingent responsiveness (e.g., someone offering or showing you an object) elicited activations in regions of the right posterior temporal sulcus and yielded greater pupil dilation corresponding to a model of coupled dynamics (joint action). In contrast, the social-cognitive perception of someone "privately" manipulating an object elicited activation in medial prefrontal cortex, the right inferior frontal gyrus and right inferior parietal lobus, regions normally associated with Theory of Mind and with the mirror neuron system. Our findings support a distinction in social cognition between social observation and social interaction, and demonstrate that simple ostensive cues may shift participants' experience, behavior, and brain activity between these modes. The identification of a distinct, interactive mode has implications for research on social cognition, both in everyday life and in clinical conditions.

  11. Interaction versus Observation: distinctive modes of social cognition in human brain and behavior? A combined fMRI and eye-tracking study.

    Directory of Open Access Journals (Sweden)

    Kristian eTylen

    2012-12-01

    Full Text Available Human cognition has usually been approached on the level of individual minds and brains, but social interaction is a challenging case. Is it best thought of as a self-contained individual cognitive process aiming at an ‘understanding of the other’, or should it rather be approached as an collective, inter-personal process where individual cognitive components interact on a moment-to-moment basis to form coupled dynamics? In a combined fMRI and eye tracking study we directly contrasted these models of social cognition. We found that the perception of situations affording social contingent responsiveness (e.g. someone offering or showing you an object elicited activations in regions of the right posterior temporal sulcus and yielded greater pupil dilation corresponding to a model of coupled dynamics (joint action. In contrast, the social-cognitive perception of someone ‘privately’ manipulating an object elicited activation in medial prefrontal cortex, the right inferior frontal gyrus and right inferior parietal lobus, regions normally associated with Theory of Mind and with the mirror neuron system. Our findings support a distinction in social cognition between social observation and social interaction, and demonstrate that simple ostensive cues may shift participants’ experience, behavior and brain activity between these modes. The identification of a distinct, interactive mode has implications for research on social cognition, both in everyday life and in clinical conditions.

  12. Eye safe laser range finders

    International Nuclear Information System (INIS)

    Snir, M.; Margaliot, M.; Amitzi, A.

    2004-01-01

    During the 1970's, Ruby (Q switched) laser based range finders with a wavelength of 694nm were first used. These lasers operated in a pulse mode within the visible light range and produced a risk for the eye retina. The laser beam striking the macula could damage the eye and might cause blindness. Over the years, Nd:YAG (Q switched) lasers were developed (operating at 1064nm) for range finding and designation uses. The wavelength of these lasers, operating in the near Infra-Red range (invisible), is also focused tightly on the retina. The human eye does not respond to the invisible light so there is no natural protection (eye blink reflex) as in the visible light. The operation of these lasers worldwide, especially when the laser beam is exposed, causes occasional eye accidents. Another risk is stemming from the use of observation systems with a high optical gain, in the laser operation areas, which enlarge the range of risk quite significantly. Therefore, research and development efforts were invested in order to introduce eye safe lasers. One of the solutions for this problem is presented in following document

  13. New medium used in the differentiation of human pluripotent stem cells to retinal cells is comparable to fetal human eye tissue.

    Science.gov (United States)

    Wang, Xiaobing; Xiong, Kai; Lin, Cong; Lv, Lei; Chen, Jing; Xu, Chongchong; Wang, Songtao; Gu, Dandan; Zheng, Hua; Yu, Hurong; Li, Yan; Xiao, Honglei; Zhou, Guomin

    2015-06-01

    Human pluripotent stem cells (hPSCs) have the potential to differentiate along the retinal lineage. However, most induction systems are dependent on multiple small molecular compounds such as Dkk-1, Lefty-A, and retinoic acid. In the present study, we efficiently differentiated hPSCs into retinal cells using a retinal differentiation medium (RDM) without the use of small molecular compounds. This novel differentiation system recapitulates retinal morphogenesis in humans, i.e. hPSCs gradually differentiate into optic vesicle-shaped spheres, followed by optic cup-shaped spheres and, lastly, retinal progenitor cells. Furthermore, at different stages, hPSC-derived retinal cells mirror the transcription factor expression profiles seen in their counterparts during human embryogenesis. Most importantly, hinge epithelium was found between the hPSC-derived neural retina (NR) and retinal pigment epithelium (RPE). These data suggest that our culture system provides a new method for generating hPSC-derived retinal cells that, for the first time, might be used in human transplantation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Eye Movements in Reading as Rational Behavior

    Science.gov (United States)

    Bicknell, Klinton

    2011-01-01

    Moving one's eyes while reading is one of the most complex everyday tasks humans face. To perform efficiently, readers must make decisions about when and where to move their eyes every 200-300ms. Over the past decades, it has been demonstrated that these fine-grained decisions are influenced by a range of linguistic properties of the text, and…

  15. Combining Sodium Hyaluronate and Polyvinylpyrrolidone Therapies for the Rabbit Cornea: A New Approach to Relief of the Human Dry Eye Syndrome.

    Science.gov (United States)

    Ehrenberg, Moshe; Zolotariov, Eyal; Loeb, Emmanuel; Poliansky, Vadim; Levy, Aharon

    2015-09-01

    The novel combination of 0.1% sodium hyaluronate (HA) and 5.0% polyvinylpyrrolidone (PVP) into one eyedrop was investigated to test the hypothesis of its increased relief of dry eye syndrome (DES). We evaluated HA and PVP, either alone, or in combination, by utilizing 16 rabbits, where their right eyes received one or two different eyedrops, and their left eyes, as controls, received none. The DES replica in rabbits was induced by 0.1% benzalkonium chloride (BAC) eyedrops. BAC was instilled into the right eyes of all rabbits, which were divided into four groups of four. In Group 1 M, the rabbits received only BAC. A second eyedrop given to the right eyes of Group 2 M was HA, of Group 3 M was PVP, and of Group 4 M was the combination of both HA and PVP. All eyes were followed clinically for 14 d, and thereafter, examined histopathologically. Clinically, the HA+PVP combination yielded the least perilimbal conjunctival erythema (p eyes in the combination group 4 M displayed the greatest preservation of the corneal epithelium (p < 0.001) and of the perilimbal conjunctival goblet cell density (p < 0.001). This unique combination of both HA and PVP into one eyedrop, was more potent than either treatment alone in protecting the ocular surface. A preparation, containing both HA and PVP may become useful for DES patients.

  16. Eye changes induced by radium

    International Nuclear Information System (INIS)

    Taylor, G.N.; Lloyd, R.D.; Shabestari, Lorraine; Angus, Walter; Muggenburg, B.A.

    1989-01-01

    This report presents some features of the radium induced eye syndrome observed in beagles, including the prominence of intraocular pigmentary lesions and compares these with the results of rodent studies (Onychomys leucogaster) featuring a heavily pigmented uvea, and with the radiation syndrome reported in humans. (author)

  17. Revised genomic consensus for the hypermethylated CpG island region of the human L1 transposon and integration sites of full length L1 elements from recombinant clones made using methylation-tolerant host strains

    DEFF Research Database (Denmark)

    Crowther, P J; Doherty, J P; Linsenmeyer, M E

    1991-01-01

    preferentially from L1 members which have accumulated mutations that have removed sites of methylation. We present a revised consensus from the 5' presumptive control region of these elements. This revised consensus contains a consensus RNA polymerase III promoter which would permit the synthesis of transcripts......Efficient recovery of clones from the 5' end of the human L1 dispersed repetitive elements necessitates the use of deletion mcr- host strains since this region contains a CpG island which is hypermethylated in vivo. Clones recovered with conventional mcr+ hosts seem to have been derived...... from the 5' end of full length L1 elements. Such potential transcripts are likely to exhibit a high degree of secondary structure. In addition, we have determined the flanking sequences for 6 full length L1 elements. The majority of full length L1 clones show no convincing evidence for target site...

  18. Efficient programming of human eye conjunctiva-derived induced pluripotent stem (ECiPS) cells into definitive endoderm-like cells.

    Science.gov (United States)

    Massumi, Mohammad; Hoveizi, Elham; Baktash, Parvaneh; Hooti, Abdollah; Ghazizadeh, Leili; Nadri, Samad; Pourasgari, Farzaneh; Hajarizadeh, Athena; Soleimani, Masoud; Nabiuni, Mohammad; Khorramizadeh, Mohammad R

    2014-03-10

    Due to pluripotency of induced pluripotent stem (iPS) cells, and the lack of immunological incompatibility and ethical issues, iPS cells have been considered as an invaluable cell source for future cell replacement therapy. This study was aimed first at establishment of novel iPS cells, ECiPS, which directly reprogrammed from human Eye Conjunctiva-derived Mesenchymal Stem Cells (EC-MSCs); second, comparing the inductive effects of Wnt3a/Activin A biomolecules to IDE1 small molecule in derivation of definitive endoderm (DE) from the ECiPS cells. To that end, first, the EC-MSCs were transduced by SOKM-expressing lentiviruses and characterized for endogenous expression of embryonic markers Then the established ECiPS cells were induced to DE formation by Wnt3a/Activin A or IDE1. Quantification of GSC, Sox17 and Foxa2 expression, as DE-specific markers, in both mRNA and protein levels revealed that induction of ECiPS cells by either Wnt3a/Activin A or IDE1 could enhance the expression level of the genes; however the levels of increase were higher in Wnt3a/Activin A induced ECiPS-EBs than IDE1 induced cells. Furthermore, the flow cytometry analyses showed no synergistic effect between Activin A and Wnt3a to derive DE-like cells from ECiPS cells. The comparative findings suggest that although both Wnt3a/Activin A signaling and IDE1 molecule could be used for differentiation of iPS into DE cells, the DE-inducing effect of Wnt3a/Activin A was statistically higher than IDE1. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Prevalidation trial for a novel in vitro eye irritation test using the reconstructed human cornea-like epithelial model, MCTT HCE™.

    Science.gov (United States)

    Yang, Hyeri; Kim, Da-Eun; Jang, Won-Hee; An, Susun; Cho, Sun-A; Jung, Mi-Sook; Lee, Ji Eun; Yeo, Kyung-Wook; Koh, Sang Bum; Jeong, Tae-Cheon; Kang, Mi-Jeong; Chun, Young-Jin; Lee, Su-Hyon; Lim, Kyung-Min; Bae, SeungJin

    2017-03-01

    Here, we report the results of a prevalidation trial for an in vitro eye irritation test (EIT) using the reconstructed human cornea-like epithelium, MCTT HCE™. The optimal cutoff to determine irritation in the prediction model was established at 35% with the receiver operation characteristics(ROC) curve for 126 substances. Within-lab(WL) and between-lab(BL) reproducibility was tested for 20 reference substances by 3 participating laboratories. Viability data described by mean±SD or ±1/2 difference between duplicate wells, and scatter plots, demonstrated the WL/BL consistency. WL/BL concordance with the binary decision, whether non-irritant or irritant was estimated to be 85-95% and 95%, respectively. WL/BL reproducibility of viability data was further supported by a strong correlation(ICC, r>0.9). WL/BL agreement of binary decisions was also examined by Fleiss' Kappa statistics, which showed a strong level of agreement (>0.78), nevertheless weaker than the reproducibility of the viability. The EIT with MCTT HCE™ exhibited a sensitivity of 82.2% (60/73), a specificity of 81.1% (43/53), and an accuracy of 81.8% (103/126) for 126 reference substances (for liquids; a sensitivity of 100% (47/47), a specificity of 70.6% (24/34), and an accuracy of 87.7% (71/81), and for solids, a sensitivity of 50% (13/26), a specificity of 100% (19/19), and an accuracy of 71.1% (32/45), suggesting that the accuracy is satisfactory but the sensitivity needs improvement, which shall be addressed through correcting the poor sensitivity for solid substances in future full validation trials. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Design, Sensing and Control of a Robotic Prosthetic Eye for Natural Eye Movement

    Directory of Open Access Journals (Sweden)

    J. J. Gu

    2006-01-01

    Full Text Available Loss of an eye is a tragedy for a person, who may suffer psychologically and physically. This paper is concerned with the design, sensing and control of a robotic prosthetic eye that moves horizontally in synchronization with the movement of the natural eye. Two generations of robotic prosthetic eye models have been developed. The first generation model uses an external infrared sensor array mounted on the frame of a pair of eyeglasses to detect the natural eye movement and to feed the control system to drive the artificial eye to move with the natural eye. The second generation model removes the impractical usage of the eye glass frame and uses the human brain EOG (electro-ocular-graph signal picked up by electrodes placed on the sides of a person's temple to carry out the same eye movement detection and control tasks as mentioned above. Theoretical issues on sensor failure detection and recovery, and signal processing techniques used in sensor data fusion, are studied using statistical methods and artificial neural network based techniques. In addition, practical control system design and implementation using micro-controllers are studied and implemented to carry out the natural eye movement detection and artificial robotic eye control tasks. Simulation and experimental studies are performed, and the results are included to demonstrate the effectiveness of the research project reported in this paper.

  1. Nutrients for the aging eye

    Directory of Open Access Journals (Sweden)

    Rasmussen HM

    2013-06-01

    Full Text Available Helen M Rasmussen,1 Elizabeth J Johnson2 1Educational Studies, Lesley University, Cambridge, MA, USA; 2Carotenoid and Health Laboratory, Jean Mayer US Department of Agriculture Human Nutrition Research Center on Aging at Tufts University, Boston, MA, USA Abstract: The incidence of age-related eye diseases is expected to rise with the aging of the population. Oxidation and inflammation are implicated in the etiology of these diseases. There is evidence that dietary antioxidants and anti-inflammatories may provide benefit in decreasing the risk of age-related eye disease. Nutrients of interest are vitamins C and E, β-carotene, zinc, lutein, zeaxanthin, and the omega-3 fatty acids eicosapentaenoic acid and docosahexaenoic acid. While a recent survey finds that among the baby boomers (45–65 years old, vision is the most important of the five senses, well over half of those surveyed were not aware of the important nutrients that play a key role in eye health. This is evident from a national survey that finds that intake of these key nutrients from dietary sources is below the recommendations or guidelines. Therefore, it is important to educate this population and to create an awareness of the nutrients and foods of particular interest in the prevention of age-related eye disease. Keywords: nutrition, aging, eye health

  2. Eyes Wide Open

    Directory of Open Access Journals (Sweden)

    Zoi Manesi

    2016-04-01

    Full Text Available Research from evolutionary psychology suggests that the mere presence of eye images can promote prosocial behavior. However, the “eye images effect” is a source of considerable debate, and findings across studies have yielded somewhat inconsistent support. We suggest that one critical factor may be whether the eyes really need to be watching to effectively enhance prosocial behavior. In three experiments, we investigated the impact of eye images on prosocial behavior, assessed in a laboratory setting. Participants were randomly assigned to view an image of watching eyes (eyes with direct gaze, an image of nonwatching eyes (i.e., eyes closed for Study 1 and averted eyes for Studies 2 and 3, or an image of flowers (control condition. Upon exposure to the stimuli, participants decided whether or not to help another participant by completing a dull cognitive task. Three independent studies produced somewhat mixed results. However, combined analysis of all three studies, with a total of 612 participants, showed that the watching component of the eyes is important for decision-making in this context. Images of watching eyes led to significantly greater inclination to offer help as compared to images of nonwatching eyes (i.e., eyes closed and averted eyes or images of flowers. These findings suggest that eyes gazing at an individual, rather than any proxy to social presence (e.g., just the eyes, serve as a reminder of reputation. Taken together, we conclude that it is “eyes that pay attention” that can lift the veil of anonymity and potentially facilitate prosocial behavior.

  3. Dry eyes : a commonly missed eye condition

    OpenAIRE

    Vella, Mario;

    2014-01-01

    Tears are an important component in providing moisture and lubrication for the eyes, thereby maintaining vision and comfort. Dry eyes (keratoconjunctivitis sicca) result when there is either decreased production of tears or by poor tear quality which in turn lead to more rapid evaporation.

  4. In vitro assessment of eye irritancy using the Reconstructed Human Corneal Epithelial SkinEthic HCE model: application to 435 substances from consumer products industry.

    Science.gov (United States)

    Cotovio, José; Grandidier, Marie-Hélène; Lelièvre, Damien; Bremond, Christelle; Amsellem, Carolle; Maloug, Saber; Ovigne, Jean-Marc; Loisel-Joubert, Sophie; Lee, Aline Van Der; Minondo, Anne-Marie; Capallere, Christophe; Bertino, Béatrice; Alépée, Nathalie; Tinois-Tessonneaud, Estelle; de Fraissinette, Anne De Brugerolle; Meunier, Jean-Roch; Leclaire, Jacques

    2010-03-01

    The 7th amendment of the EU Cosmetics Directive led to the ban of eye irritation testing for cosmetic ingredients in animals, effective from March 11th 2009. Over the last 20years, many efforts have been made to find reliable and relevant alternative methods. The SkinEthic HCE model was used to evaluate the in vitro eye irritancy potential of substances from a cosmetic industry portfolio. An optimized protocol based on a specific 1-h treatment and a 16-h post-treatment incubation period was first assessed on a set of 102 substances. The prediction model (PM) based on a 50% viability cut-off, allowed to draw up two classes (Irritants and Non-Irritants), with good associated sensitivity (86.2%) and specificity (83.5%). To check the robustness of the method, the evaluated set was expanded up to 435 substances. Final performances maintained a high level and were characterized by an overall accuracy value > 82% when using EU or GHS classification rules. Results showed that the SkinEthic HCE test method is a promising in vitro tool for the prediction of eye irritancy. Optimization datasets were shared with the COLIPA Eye Irritation Project Team and ECVAM experts, and reviewed as part of an ongoing progression to enter an ECVAM prospective validation study for eye irritation. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  5. The highly myopic eye--oculometric considerations

    DEFF Research Database (Denmark)

    Fledelius, Hans C; Goldschmidt, Ernst

    2012-01-01

    by Francois and Goes, not all long eyes have flat corneas. In our high myopia series, a significant subgroup could thus be discerned who had peaked corneas, which led to mathematically slight reduction of the usual positive correlation between axial length and curvature radius in the ametropia population...

  6. The small FOXP1 isoform predominantly expressed in activated B cell-like diffuse large B-cell lymphoma and full-length FOXP1 exert similar oncogenic and transcriptional activity in human B cells.

    Science.gov (United States)

    van Keimpema, Martine; Grüneberg, Leonie J; Schilder-Tol, Esther J M; Oud, Monique E C M; Beuling, Esther A; Hensbergen, Paul J; de Jong, Johann; Pals, Steven T; Spaargaren, Marcel

    2017-03-01

    The forkhead transcription factor FOXP1 is generally regarded as an oncogene in activated B cell-like diffuse large B-cell lymphoma. Previous studies have suggested that a small isoform of FOXP1 rather than full-length FOXP1, may possess this oncogenic activity. Corroborating those studies, we herein show that activated B cell-like diffuse large B-cell lymphoma cell lines and primary activated B cell-like diffuse large B-cell lymphoma cells predominantly express a small FOXP1 isoform, and that the 5'-end of the Foxp1 gene is a common insertion site in murine lymphomas in leukemia virus- and transposon-mediated insertional mutagenesis screens. By combined mass spectrometry, (quantative) reverse transcription polymerase chain reaction/sequencing, and small interfering ribonucleic acid-mediated gene silencing, we determined that the small FOXP1 isoform predominantly expressed in activated B cell-like diffuse large B-cell lymphoma lacks the N-terminal 100 amino acids of full-length FOXP1. Aberrant overexpression of this FOXP1 isoform (ΔN100) in primary human B cells revealed its oncogenic capacity; it repressed apoptosis and plasma cell differentiation. However, no difference in potency was found between this small FOXP1 isoform and full-length FOXP1. Furthermore, overexpression of full-length FOXP1 or this small FOXP1 isoform in primary B cells and diffuse large B-cell lymphoma cell lines resulted in similar gene regulation. Taken together, our data indicate that this small FOXP1 isoform and full-length FOXP1 have comparable oncogenic and transcriptional activity in human B cells, suggesting that aberrant expression or overexpression of FOXP1, irrespective of the specific isoform, contributes to lymphomagenesis. These novel insights further enhance the value of FOXP1 for the diagnostics, prognostics, and treatment of diffuse large B-cell lymphoma patients. Copyright© Ferrata Storti Foundation.

  7. Novel phytoceramides containing fatty acids of diverse chain lengths are better than a single C18-ceramide N-stearoyl phytosphingosine to improve the physiological properties of human stratum corneum

    Directory of Open Access Journals (Sweden)

    Oh MJ

    2017-09-01

    Full Text Available Myoung Jin Oh,1 Young Hoon Cho,1 So Yoon Cha,1 Eun Ok Lee,2 Jin Wook Kim,2 Sun Ki Kim,2 Chang Seo Park1 1Department of Chemical and Biochemical Engineering, Dongguk University, Chung-gu, Seoul, 2LCS Biotech, Gwonseon-gu, Suwon-si, Gyeonggi-do, Republic of Korea Abstract: Ceramides in the human stratum corneum (SC are a mixture of diverse N-acylated fatty acids (FAs with different chain lengths. C24 is the major class of FAs of ceramides. However, there are also other classes of ceramides with diverse chain lengths of FAs, and these lengths generally range from C16 to C26. This study aimed to prepare several types of phytoceramide containing diverse chain lengths of N-acylated FAs and compare them with C18-ceramide N-stearoyl phytosphingosine (NP in terms of their effects on the physiological properties of the SC. We chose natural oils, such as horse fat oil, shea butter, sunflower oil, and a mixture of macadamia nut, shea butter, moringa, and meadowfoam seed oil, as sources of FAs and phytosphingosine as a sphingoid backbone to synthesize diverse phytoceramides. Each phytoceramide exhibited a distinctive formation of the lamellar structure, and their FA profiles were similar to those of their respective natural oil. The skin barrier properties, as analyzed in human skin, clearly demonstrated that all the phytoceramides improved the recovery rate of the damaged SC and enhanced hydration better than C18-ceramide NP did. In conclusion, natural oil-derived phytoceramides could represent a novel class of ceramides for cosmetic applications in the development of an ideal skin barrier moisturizer. Keywords: fatty acid, chain length, phytoceramide, skin barrier, natural oil

  8. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Kierstan Boyd Reviewed By: Brenda Pagan-Duran MD Sep. 01, 2017 Our eyes need tears to stay ... tear duct to insert a permanent punctal plug? Sep 12, 2017 Why are my eyes bloodshot when ...

  9. What Is Dry Eye?

    Medline Plus

    Full Text Available ... seasonal allergens and dry eye Apr 27, 2015 Choosing Wisely When It Comes to Eye Care, Part ... Name: Member ID: * Phone Number: * Email: * Enter code: * Message: Thank you Your feedback has been sent.

  10. About the Eye

    Medline Plus

    Full Text Available ... Disease Education Program Glaucoma Education Program Low Vision Education Program ... Eye Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety ...

  11. Pink Eye (Conjunctivitis)

    Science.gov (United States)

    ... or child care if you're not able to take time off — just stay consistent in practicing good hygiene. Preventing pink eye in newborns Newborns' eyes are susceptible to bacteria normally present in the mother's birth canal. ...

  12. About the Eye

    Medline Plus

    Full Text Available ... Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety ... much as it does on your eyes. ... of Health | USA.gov NIH…Turning Discovery Into Health ®

  13. About the Eye

    Medline Plus

    Full Text Available ... Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the ...

  14. Preventing Eye Injuries

    Science.gov (United States)

    ... Your Eyes Sep 20, 2017 Eye Injuries from Laundry Packets On the Rise Jun 30, 2017 ... Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  15. About the Eye

    Medline Plus

    Full Text Available ... National Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, ...

  16. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye Health Home Annual Meeting Clinical Education Practice Management Member Services Advocacy Foundation About Subspecialties & More Academy Publications EyeNet Ophthalmology Ophthalmology Retina Information for: International Ophthalmologists Media Medical Students Patients and ...

  17. What Is Dry Eye?

    Medline Plus

    Full Text Available ... right type of tears or tear film . How do tears work? When you blink, a film of ... layer cleans the eye, washing away particles that do not belong in the eye. This layer comes ...

  18. About the Eye

    Medline Plus

    Full Text Available ... The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid ... Your eyes are made up of many different parts that work together to help you see. Check out the ...

  19. About the Eye

    Medline Plus

    Full Text Available ... Vision Education Program Hispanic/Latino Program Vision and Aging Program African American Program Training and Jobs Fellowships ... Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes ...

  20. About the Eye

    Medline Plus

    Full Text Available ... Clinical Director Laboratories, Sections and Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office ... Diabetic Eye Disease Education Program Glaucoma Education Program Low Vision Education Program Hispanic/Latino Program Vision and ...

  1. About the Eye

    Medline Plus

    Full Text Available ... Home » NEI for Kids » About the Eye Listen All About Vision About the Eye Ask a Scientist ... you can see and make sense of the world around you. Did You Know? Vision depends on ...

  2. About the Eye

    Medline Plus

    Full Text Available ... search for current job openings visit HHS USAJobs Home >> NEI for Kids >> About the Eye Listen All ... much as it does on your eyes. NEI Home Contact Us A-Z Site Map NEI on ...

  3. About the Eye

    Medline Plus

    Full Text Available ... NIH), the National Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of ...

  4. Eye Involvement in TSC

    Science.gov (United States)

    ... eye involvement. Nonretinal and Retinal Eye Findings Facial angiofibromas may involve the eyelids of individuals with TSC, ... the hamartomas have many blood vessels (as are angiofibromas of the skin). Less than half of the ...

  5. What Is Dry Eye?

    Medline Plus

    Full Text Available ... removed or pushed down the tear duct to insert a permanent punctal plug? Sep 12, 2017 Why ... Eye from Jennifer Aniston Sep 02, 2016 The link between seasonal allergens and dry eye Apr 27, ...

  6. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Services Advocacy Foundation About Subspecialties & More Eye Health Home Annual Meeting Clinical Education Practice Management Member Services Advocacy Foundation About Subspecialties & More Academy Publications EyeNet ...

  7. About the Eye

    Medline Plus

    Full Text Available ... First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun Stuff Cool Eye Tricks ... website is maintained by the NEI Office of Science Communications, Public Liaison, and Education. Technical questions about ...

  8. About the Eye

    Medline Plus

    Full Text Available ... search for current job openings visit HHS USAJobs Home » NEI for Kids » About the Eye Listen All ... much as it does on your eyes. NEI Home Contact Us A-Z Site Map NEI on ...

  9. About the Eye

    Medline Plus

    Full Text Available ... the special health problems and requirements of the blind.” News & Events Events Calendar NEI Press Releases News ... First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun Stuff Cool Eye Tricks ...

  10. Impaired exploratory eye movements in children with Asperger's syndrome.

    Science.gov (United States)

    Ohya, Takashi; Morita, Kiichiro; Yamashita, Yushiro; Egami, Chiyomi; Ishii, Youhei; Nagamitsu, Shinichiro; Matsuishi, Toyojiro

    2014-03-01

    Previous eye-tracking studies using an eye mark recorder have reported that disturbances in exploratory eye movements in adult schizophrenic patients are associated with social functioning. The current study sought to determine whether exploratory eye-movement disturbances are present in children with Asperger's syndrome (AS) compared with typically developing (TD) children. MATERIALS/PARTICIPANTS: The participants were 23 children with AS and 23 age-matched TD children. We measured exploratory eye movements using an EMR-8B eye mark recorder and an exploratory eye movement-measuring device. Eye movements were recorded while participants freely observed a geometric figure (free viewing task), and while they complied with the instructions of an experimenter (repeat-comparison task). We assessed eye fixation points (EFPs) and total eye scanning length (TESL) in all tasks, and measured the responsive search score (RSS) in the repeat-comparison task. In the free viewing task, children with AS exhibited significantly shorter TESL compared with TD children. In the repeat-comparison task, children with AS exhibited significantly lower RSS. Autism Spectrum Screening Questionnaire scores were negatively correlated with both EFP and TESL, but not RSS. The current results revealed that children with AS exhibited dysfunction in exploratory eye movements. Thus, assessing exploratory eye movements in a repeat-comparison task may be useful for detecting social impairment among children with AS. Copyright © 2013 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  11. Immunology of the eye

    OpenAIRE

    Weronika Ratajczak; Beata Tokarz-Deptuła; Wiesław Deptuła

    2018-01-01

    The eye is an organ of sight characterized by unusual immunological properties, resulting from its anatomical structure and physiology, as well as the presence of specific elements that, through the mechanisms of innate and adaptive immunity, provide homeostasis of the eyeball. This article reviews the defensive elements of individual eye structures: conjunctiva, cornea, lacrimal gland, anterior chamber of the eye, uvea, retina and eye-associated lymphoid tissue (EALT), where we distinguish a...

  12. Diet, nutrition and telomere length.

    Science.gov (United States)

    Paul, Ligi

    2011-10-01

    The ends of human chromosomes are protected by DNA-protein complexes termed telomeres, which prevent the chromosomes from fusing with each other and from being recognized as a double-strand break by DNA repair proteins. Due to the incomplete replication of linear chromosomes by DNA polymerase, telomeric DNA shortens with repeated cell divisions until the telomeres reach a critical length, at which point the cells enter senescence. Telomere length is an indicator of biological aging, and dysfunction of telomeres is linked to age-related pathologies like cardiovascular disease, Parkinson disease, Alzheimer disease and cancer. Telomere length has been shown to be positively associated with nutritional status in human and animal studies. Various nutrients influence telomere length potentially through mechanisms that reflect their role in cellular functions including inflammation, oxidative stress, DNA integrity, DNA methylation and activity of telomerase, the enzyme that adds the telomeric repeats to the ends of the newly synthesized DNA. Copyright © 2011 Elsevier Inc. All rights reserved.

  13. The all seeing eye?

    NARCIS (Netherlands)

    Koenderink, Jan J.

    2014-01-01

    The All Seeing Eye? Did you know that you are probably a believer in the All Seeing Eye? The odds are that I’m right—why? Well, the bulk of mainstream vision literature blindly relies on the All Seeing Eye. It is written all over papers, albeit between the lines. Understandably so, for scientists

  14. About the Eye

    Medline Plus

    Full Text Available ... other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health ... Eye Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and ...

  15. Fish eye optics

    Science.gov (United States)

    Hudec, R.; Michalova, S.

    2017-07-01

    We report on small student (high—school) project of the Czech Academy of Sciences dealing with animal (fish) eyes and possible application in science and technology. Albeit most fishes have refractive eyes, the recent discoveries confirm that some fishes have reflective eyes with strange arrangements as well.

  16. Eye and orbital cavity

    International Nuclear Information System (INIS)

    Panfilova, G.V.; Koval', G.Yu.

    1984-01-01

    Radioanatomy of eyes and orbit is described. Diseases of the orbit (developmental anomalies, inflammatory diseases, lacrimal apparatus deseases, toxoplasmosis, tumors and cysts et al.), methods of foreign body localization in the eye are considered. Roentgenograms of the orbit and calculation table for foreign body localization in spherical eyes of dissimilar diameter are presented

  17. Recognizing and Treating Eye Injuries

    Science.gov (United States)

    ... Eye Injuries First Aid for Eye Scratches Protective Eyewear Children’s Eye Injuries: Prevention and Care Eye Injuries ... Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of Service For ...

  18. EYE GAZE TRACKING

    DEFF Research Database (Denmark)

    2017-01-01

    This invention relates to a method of performing eye gaze tracking of at least one eye of a user, by determining the position of the center of the eye, said method comprising the steps of: detecting the position of at least three reflections on said eye, transforming said positions to spanning...... a normalized coordinate system spanning a frame of reference, wherein said transformation is performed based on a bilinear transformation or a non linear transformation e.g. a möbius transformation or a homographic transformation, detecting the position of said center of the eye relative to the position...... of said reflections and transforming this position to said normalized coordinate system, tracking the eye gaze by tracking the movement of said eye in said normalized coordinate system. Thereby calibration of a camera, such as knowledge of the exact position and zoom level of the camera, is avoided...

  19. Fetal Eye Movements on Magnetic Resonance Imaging

    Science.gov (United States)

    Woitek, Ramona; Kasprian, Gregor; Lindner, Christian; Stuhr, Fritz; Weber, Michael; Schöpf, Veronika; Brugger, Peter C.; Asenbaum, Ulrika; Furtner, Julia; Bettelheim, Dieter; Seidl, Rainer; Prayer, Daniela

    2013-01-01

    Objectives Eye movements are the physical expression of upper fetal brainstem function. Our aim was to identify and differentiate specific types of fetal eye movement patterns using dynamic MRI sequences. Their occurrence as well as the presence of conjugated eyeball motion and consistently parallel eyeball position was systematically analyzed. Methods Dynamic SSFP sequences were acquired in 72 singleton fetuses (17–40 GW, three age groups [17–23 GW, 24–32 GW, 33–40 GW]). Fetal eye movements were evaluated according to a modified classification originally published by Birnholz (1981): Type 0: no eye movements; Type I: single transient deviations; Type Ia: fast deviation, slower reposition; Type Ib: fast deviation, fast reposition; Type II: single prolonged eye movements; Type III: complex sequences; and Type IV: nystagmoid. Results In 95.8% of fetuses, the evaluation of eye movements was possible using MRI, with a mean acquisition time of 70 seconds. Due to head motion, 4.2% of the fetuses and 20.1% of all dynamic SSFP sequences were excluded. Eye movements were observed in 45 fetuses (65.2%). Significant differences between the age groups were found for Type I (p = 0.03), Type Ia (p = 0.031), and Type IV eye movements (p = 0.033). Consistently parallel bulbs were found in 27.3–45%. Conclusions In human fetuses, different eye movement patterns can be identified and described by MRI in utero. In addition to the originally classified eye movement patterns, a novel subtype has been observed, which apparently characterizes an important step in fetal brainstem development. We evaluated, for the first time, eyeball position in fetuses. Ultimately, the assessment of fetal eye movements by MRI yields the potential to identify early signs of brainstem dysfunction, as encountered in brain malformations such as Chiari II or molar tooth malformations. PMID:24194885

  20. Fetal eye movements on magnetic resonance imaging.

    Science.gov (United States)

    Woitek, Ramona; Kasprian, Gregor; Lindner, Christian; Stuhr, Fritz; Weber, Michael; Schöpf, Veronika; Brugger, Peter C; Asenbaum, Ulrika; Furtner, Julia; Bettelheim, Dieter; Seidl, Rainer; Prayer, Daniela

    2013-01-01

    Eye movements are the physical expression of upper fetal brainstem function. Our aim was to identify and differentiate specific types of fetal eye movement patterns using dynamic MRI sequences. Their occurrence as well as the presence of conjugated eyeball motion and consistently parallel eyeball position was systematically analyzed. Dynamic SSFP sequences were acquired in 72 singleton fetuses (17-40 GW, three age groups [17-23 GW, 24-32 GW, 33-40 GW]). Fetal eye movements were evaluated according to a modified classification originally published by Birnholz (1981): Type 0: no eye movements; Type I: single transient deviations; Type Ia: fast deviation, slower reposition; Type Ib: fast deviation, fast reposition; Type II: single prolonged eye movements; Type III: complex sequences; and Type IV: nystagmoid. In 95.8% of fetuses, the evaluation of eye movements was possible using MRI, with a mean acquisition time of 70 seconds. Due to head motion, 4.2% of the fetuses and 20.1% of all dynamic SSFP sequences were excluded. Eye movements were observed in 45 fetuses (65.2%). Significant differences between the age groups were found for Type I (p = 0.03), Type Ia (p = 0.031), and Type IV eye movements (p = 0.033). Consistently parallel bulbs were found in 27.3-45%. In human fetuses, different eye movement patterns can be identified and described by MRI in utero. In addition to the originally classified eye movement patterns, a novel subtype has been observed, which apparently characterizes an important step in fetal brainstem development. We evaluated, for the first time, eyeball position in fetuses. Ultimately, the assessment of fetal eye movements by MRI yields the potential to identify early signs of brainstem dysfunction, as encountered in brain malformations such as Chiari II or molar tooth malformations.