WorldWideScience

Sample records for human eye contact

  1. Region of eye contact of humanoid Nao robot is similar to that of a human

    NARCIS (Netherlands)

    Cuijpers, R.H.; Pol, van der D.; Herrmann, G.; Pearson, M.J.; Lenz, A.; Bremner, P.; Spiers, A.; Leonards, U.

    2013-01-01

    Eye contact is an important social cue in human-human interaction, but it is unclear how easily it carries over to humanoid robots. In this study we investigated whether the tolerance of making eye contact is similar for the Nao robot as compared to human lookers. We measured the region of eye

  2. Human sensitivity to eye contact in 2D and 3D videoconferencing

    NARCIS (Netherlands)

    Eijk, van R.L.J.; Kuijsters, A.; Dijkstra, K.I.; IJsselsteijn, W.A.

    2010-01-01

    Gaze awareness and eye contact serve important functions in social interaction. In order to maintain those functions in 2D and 3D videoconferencing systems, human sensitivity to eye contact and gaze direction needs to be taken into account in the design of such systems. Here we experimentally

  3. Effects of eye contact and iconic gestures on message retention in human-robot interaction

    NARCIS (Netherlands)

    Dijk, van E.T.; Torta, E.; Cuijpers, R.H.

    2013-01-01

    The effects of iconic gestures and eye contact on message retention in human-robot interaction were investigated in a series of experiments. A humanoid robot gave short verbal messages to participants, accompanied either by iconic gestures or no gestures while making eye contact with the participant

  4. Simultaneous measurement of eye stiffness and contact area for living human eyes.

    Science.gov (United States)

    Kurita, Yuichi; Iida, Yoshichika; Kaneko, Makoto; Mishima, Hiromu K; Katakura, Seiki; Kiuchi, Yoshiaki

    2007-01-01

    Goldmann applanation tonometry is commonly used for measuring IOP (IntraOcular Pressure) to diagnose glaucoma. However, the measured IOP by the applanation tonometry is valid only under the assumption that all the subjects have the same structural eye stiffness. Abnormal eye stiffness makes abnormal corneal deformation and thus the current applanation tonometer misestimates the IOP. This study challenges to measure the eye stiffness in vivo with a non-invasive approach for detecting the abnormal deformation. The deformation of the cornea and the contact area between the probe and the cornea are simultaneously captured by cameras during the experiment. Experimental results show that some subjects have different relationship among the force, the displacement and the contact area even with same IOP. The proposed eye stiffness measurement can help detecting the abnormal deformation and the eyes with misestimated IOP.

  5. A Proactive Approach of Robotic Framework for Making Eye Contact with Humans

    Directory of Open Access Journals (Sweden)

    Mohammed Moshiul Hoque

    2014-01-01

    Full Text Available Making eye contact is a most important prerequisite function of humans to initiate a conversation with others. However, it is not an easy task for a robot to make eye contact with a human if they are not facing each other initially or the human is intensely engaged his/her task. If the robot would like to start communication with a particular person, it should turn its gaze to that person and make eye contact with him/her. However, such a turning action alone is not enough to set up an eye contact phenomenon in all cases. Therefore, the robot should perform some stronger actions in some situations so that it can attract the target person before meeting his/her gaze. In this paper, we proposed a conceptual model of eye contact for social robots consisting of two phases: capturing attention and ensuring the attention capture. Evaluation experiments with human participants reveal the effectiveness of the proposed model in four viewing situations, namely, central field of view, near peripheral field of view, far peripheral field of view, and out of field of view.

  6. See You See Me: the Role of Eye Contact in Multimodal Human-Robot Interaction.

    Science.gov (United States)

    Xu, Tian Linger; Zhang, Hui; Yu, Chen

    2016-05-01

    We focus on a fundamental looking behavior in human-robot interactions - gazing at each other's face. Eye contact and mutual gaze between two social partners are critical in smooth human-human interactions. Therefore, investigating at what moments and in what ways a robot should look at a human user's face as a response to the human's gaze behavior is an important topic. Toward this goal, we developed a gaze-contingent human-robot interaction system, which relied on momentary gaze behaviors from a human user to control an interacting robot in real time. Using this system, we conducted an experiment in which human participants interacted with the robot in a joint attention task. In the experiment, we systematically manipulated the robot's gaze toward the human partner's face in real time and then analyzed the human's gaze behavior as a response to the robot's gaze behavior. We found that more face looks from the robot led to more look-backs (to the robot's face) from human participants and consequently created more mutual gaze and eye contact between the two. Moreover, participants demonstrated more coordinated and synchronized multimodal behaviors between speech and gaze when more eye contact was successfully established and maintained.

  7. See You See Me: the Role of Eye Contact in Multimodal Human-Robot Interaction

    Science.gov (United States)

    XU, TIAN (LINGER); ZHANG, HUI; YU, CHEN

    2016-01-01

    We focus on a fundamental looking behavior in human-robot interactions – gazing at each other’s face. Eye contact and mutual gaze between two social partners are critical in smooth human-human interactions. Therefore, investigating at what moments and in what ways a robot should look at a human user’s face as a response to the human’s gaze behavior is an important topic. Toward this goal, we developed a gaze-contingent human-robot interaction system, which relied on momentary gaze behaviors from a human user to control an interacting robot in real time. Using this system, we conducted an experiment in which human participants interacted with the robot in a joint attention task. In the experiment, we systematically manipulated the robot’s gaze toward the human partner’s face in real time and then analyzed the human’s gaze behavior as a response to the robot’s gaze behavior. We found that more face looks from the robot led to more look-backs (to the robot’s face) from human participants and consequently created more mutual gaze and eye contact between the two. Moreover, participants demonstrated more coordinated and synchronized multimodal behaviors between speech and gaze when more eye contact was successfully established and maintained. PMID:28966875

  8. Contact Lens-Related Eye Infections

    Science.gov (United States)

    ... Español Eye Health / Eye Health A-Z Contact Lens-Related Eye Infections Sections Contact Lens-Related Eye ... Six Steps to Avoid Contact Lens Infections Contact Lens-Related Eye Infections Leer en Español: Infecciones relacionadas ...

  9. [Eye contact effects: A therapeutic issue?

    Science.gov (United States)

    Baltazar, M; Conty, L

    2016-12-01

    The perception of a direct gaze - that is, of another individual's gaze directed at the observer that leads to eye contact - is known to influence a wide range of cognitive processes and behaviors. We stress that these effects mainly reflect positive impacts on human cognition and may thus be used as relevant tools for therapeutic purposes. In this review, we aim (1) to provide an exhaustive review of eye contact effects while discussing the limits of the dominant models used to explain these effects, (2) to illustrate the therapeutic potential of eye contact by targeting those pathologies that show both preserved gaze processing and deficits in one or several functions that are targeted by the eye contact effects, and (3) to propose concrete ways in which eye contact could be employed as a therapeutic tool. (1) We regroup the variety of eye contact effects into four categories, including memory effects, activation of prosocial behavior, positive appraisals of self and others and the enhancement of self-awareness. We emphasize that the models proposed to account for these effects have a poor predictive value and that further descriptions of these effects is needed. (2) We then emphasize that people with pathologies that affect memory, social behavior, and self and/or other appraisal, and self-awareness could benefit from eye contact effects. We focus on depression, autism and Alzheimer's disease to illustrate our proposal. To our knowledge, no anomaly of eye contact has been reported in depression. Patients suffering from Alzheimer disease, at the early and moderate stage, have been shown to maintain a normal amount of eye contact with their interlocutor. We take into account that autism is controversial regarding whether gaze processing is preserved or altered. In the first view, individuals are thought to elude or omit gazing at another's eyes while in the second, individuals are considered to not be able to process the gaze of others. We adopt the first stance

  10. Eye Contact Modulates Cognitive Processing Differently in Children with Autism

    Science.gov (United States)

    Falck-Ytter, Terje; Carlström, Christoffer; Johansson, Martin

    2015-01-01

    In humans, effortful cognitive processing frequently takes place during social interaction, with eye contact being an important component. This study shows that the effect of eye contact on memory for nonsocial information is different in children with typical development than in children with autism, a disorder of social communication. Direct…

  11. Eye contact and Cross-cultural Communication

    Institute of Scientific and Technical Information of China (English)

    刘西娟

    2009-01-01

    It is commonly agreed by contemporary schohrs that it is important to understand the role of culture and its characteristics and potential impact on individuals engaged in cross-cultural communication.Nonverbal Communication often reveals basic culture traits.Eye contact,as a mediunq to convey emodon.attitudes and intention.phys an undeniably vital role in communication.The concentration of this paper is to discuss the functions of eye contact in communication,different information conveyed by eve contact on the basis of different cultures and the importance of understanding and respecting the rituals of eye contact in cross-culmral communication.

  12. Eye Contact Is Crucial for Referential Communication in Pet Dogs.

    Science.gov (United States)

    Savalli, Carine; Resende, Briseida; Gaunet, Florence

    2016-01-01

    Dogs discriminate human direction of attention cues, such as body, gaze, head and eye orientation, in several circumstances. Eye contact particularly seems to provide information on human readiness to communicate; when there is such an ostensive cue, dogs tend to follow human communicative gestures more often. However, little is known about how such cues influence the production of communicative signals (e.g. gaze alternation and sustained gaze) in dogs. In the current study, in order to get an unreachable food, dogs needed to communicate with their owners in several conditions that differ according to the direction of owners' visual cues, namely gaze, head, eyes, and availability to make eye contact. Results provided evidence that pet dogs did not rely on details of owners' direction of visual attention. Instead, they relied on the whole combination of visual cues and especially on the owners' availability to make eye contact. Dogs increased visual communicative behaviors when they established eye contact with their owners, a different strategy compared to apes and baboons, that intensify vocalizations and gestures when human is not visually attending. The difference in strategy is possibly due to distinct status: domesticated vs wild. Results are discussed taking into account the ecological relevance of the task since pet dogs live in human environment and face similar situations on a daily basis during their lives.

  13. Attention to eye contact in the West and East: autonomic responses and evaluative ratings.

    Science.gov (United States)

    Akechi, Hironori; Senju, Atsushi; Uibo, Helen; Kikuchi, Yukiko; Hasegawa, Toshikazu; Hietanen, Jari K

    2013-01-01

    Eye contact has a fundamental role in human social interaction. The special appearance of the human eye (i.e., white sclera contrasted with a coloured iris) implies the importance of detecting another person's face through eye contact. Empirical studies have demonstrated that faces making eye contact are detected quickly and processed preferentially (i.e., the eye contact effect). Such sensitivity to eye contact seems to be innate and universal among humans; however, several studies suggest that cultural norms affect eye contact behaviours. For example, Japanese individuals exhibit less eye contact than do individuals from Western European or North American cultures. However, how culture modulates eye contact behaviour is unclear. The present study investigated cultural differences in autonomic correlates of attentional orienting (i.e., heart rate) and looking time. Additionally, we examined evaluative ratings of eye contact with another real person, displaying an emotionally neutral expression, between participants from Western European (Finnish) and East Asian (Japanese) cultures. Our results showed that eye contact elicited stronger heart rate deceleration responses (i.e., attentional orienting), shorter looking times, and higher ratings of subjective feelings of arousal as compared to averted gaze in both cultures. Instead, cultural differences in the eye contact effect were observed in various evaluative responses regarding the stimulus faces (e.g., facial emotion, approachability etc.). The rating results suggest that individuals from an East Asian culture perceive another's face as being angrier, unapproachable, and unpleasant when making eye contact as compared to individuals from a Western European culture. The rating results also revealed that gaze direction (direct vs. averted) could influence perceptions about another person's facial affect and disposition. These results suggest that cultural differences in eye contact behaviour emerge from differential

  14. Attention to eye contact in the West and East: autonomic responses and evaluative ratings.

    Directory of Open Access Journals (Sweden)

    Hironori Akechi

    Full Text Available Eye contact has a fundamental role in human social interaction. The special appearance of the human eye (i.e., white sclera contrasted with a coloured iris implies the importance of detecting another person's face through eye contact. Empirical studies have demonstrated that faces making eye contact are detected quickly and processed preferentially (i.e., the eye contact effect. Such sensitivity to eye contact seems to be innate and universal among humans; however, several studies suggest that cultural norms affect eye contact behaviours. For example, Japanese individuals exhibit less eye contact than do individuals from Western European or North American cultures. However, how culture modulates eye contact behaviour is unclear. The present study investigated cultural differences in autonomic correlates of attentional orienting (i.e., heart rate and looking time. Additionally, we examined evaluative ratings of eye contact with another real person, displaying an emotionally neutral expression, between participants from Western European (Finnish and East Asian (Japanese cultures. Our results showed that eye contact elicited stronger heart rate deceleration responses (i.e., attentional orienting, shorter looking times, and higher ratings of subjective feelings of arousal as compared to averted gaze in both cultures. Instead, cultural differences in the eye contact effect were observed in various evaluative responses regarding the stimulus faces (e.g., facial emotion, approachability etc.. The rating results suggest that individuals from an East Asian culture perceive another's face as being angrier, unapproachable, and unpleasant when making eye contact as compared to individuals from a Western European culture. The rating results also revealed that gaze direction (direct vs. averted could influence perceptions about another person's facial affect and disposition. These results suggest that cultural differences in eye contact behaviour emerge from

  15. Training for eye contact modulates gaze following in dogs.

    Science.gov (United States)

    Wallis, Lisa J; Range, Friederike; Müller, Corsin A; Serisier, Samuel; Huber, Ludwig; Virányi, Zsófia

    2015-08-01

    Following human gaze in dogs and human infants can be considered a socially facilitated orientation response, which in object choice tasks is modulated by human-given ostensive cues. Despite their similarities to human infants, and extensive skills in reading human cues in foraging contexts, no evidence that dogs follow gaze into distant space has been found. We re-examined this question, and additionally whether dogs' propensity to follow gaze was affected by age and/or training to pay attention to humans. We tested a cross-sectional sample of 145 border collies aged 6 months to 14 years with different amounts of training over their lives. The dogs' gaze-following response in test and control conditions before and after training for initiating eye contact with the experimenter was compared with that of a second group of 13 border collies trained to touch a ball with their paw. Our results provide the first evidence that dogs can follow human gaze into distant space. Although we found no age effect on gaze following, the youngest and oldest age groups were more distractible, which resulted in a higher number of looks in the test and control conditions. Extensive lifelong formal training as well as short-term training for eye contact decreased dogs' tendency to follow gaze and increased their duration of gaze to the face. The reduction in gaze following after training for eye contact cannot be explained by fatigue or short-term habituation, as in the second group gaze following increased after a different training of the same length. Training for eye contact created a competing tendency to fixate the face, which prevented the dogs from following the directional cues. We conclude that following human gaze into distant space in dogs is modulated by training, which may explain why dogs perform poorly in comparison to other species in this task.

  16. The Effect of Eye Contact Is Contingent on Visual Awareness

    Directory of Open Access Journals (Sweden)

    Shan Xu

    2018-02-01

    Full Text Available The present study explored how eye contact at different levels of visual awareness influences gaze-induced joint attention. We adopted a spatial-cueing paradigm, in which an averted gaze was used as an uninformative central cue for a joint-attention task. Prior to the onset of the averted-gaze cue, either supraliminal (Experiment 1 or subliminal (Experiment 2 eye contact was presented. The results revealed a larger subsequent gaze-cueing effect following supraliminal eye contact compared to a no-contact condition. In contrast, the gaze-cueing effect was smaller in the subliminal eye-contact condition than in the no-contact condition. These findings suggest that the facilitation effect of eye contact on coordinating social attention depends on visual awareness. Furthermore, subliminal eye contact might have an impact on subsequent social attention processes that differ from supraliminal eye contact. This study highlights the need to further investigate the role of eye contact in implicit social cognition.

  17. Treatment of contact lens related dry eye with antibacterial honey.

    Science.gov (United States)

    Wong, Daniel; Albietz, Julie M; Tran, Huan; Du Toit, Cimonette; Li, Anita Hui; Yun, Tina; Han, Jee; Schmid, Katrina L

    2017-12-01

    Contact lens induced dry eye affects approximately 50% of contact lens wearers. The aim was to assess the effects of Manuka (Leptospermum sp.) honey eye drops (Optimel, Melcare, Australia) on dry eye in contact lens wearers. The safety of the honey eye drops in contact lens wear and contact lens wearers' compliance were also evaluated. Prospective, randomised, cross over study, examiner masked, pilot treatment trial. Twenty-four participants aged 20 to 55 years with contact lens related dry eye were recruited and randomised to two treatment groups; 20 completed the study. One group used Optimel eye drops twice a day for two weeks followed by conventional lubricant (Systane Ultra, Alcon) therapy for two weeks; the other group completed the treatments in the reverse order. Before and after each treatment dry eye symptomology, ocular surface inflammation, and tear quantity and quality were assessed. Participants completed a daily log detailing their usage of treatments and any issues. Dry eye symptoms improved significantly after Optimel treatment. Patients with more severe symptoms at baseline showed a greater improvement in symptoms. No significant differences were observed in the objective signs of dry eye; presumably because of the short treatment duration. Seventy-five% of contact lens wearers reported good adherence to Optimel treatment and 95% reported no issues using this product. Optimel Eye Drops reduce the symptoms of dry eye in contact lens wearers and are safe to use. A longer treatment period to assess the effect on clinical signs of dry eye is required. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  18. Eye contact facilitates awareness of faces during interocular suppression

    NARCIS (Netherlands)

    Stein, T.; Senju, A.; Peelen, M.V.; Sterzer, P.

    Eye contact captures attention and receives prioritized visual processing. Here we asked whether eye contact might be processed outside conscious awareness. Faces with direct and averted gaze were rendered invisible using interocular suppression. In two experiments we found that faces with direct

  19. Eye Contact Facilitates Awareness of Faces during Interocular Suppression

    Science.gov (United States)

    Stein, Timo; Senju, Atsushi; Peelen, Marius V.; Sterzer, Philipp

    2011-01-01

    Eye contact captures attention and receives prioritized visual processing. Here we asked whether eye contact might be processed outside conscious awareness. Faces with direct and averted gaze were rendered invisible using interocular suppression. In two experiments we found that faces with direct gaze overcame such suppression more rapidly than…

  20. The effects of two different types of bandage contact lenses on the healthy canine eye.

    Science.gov (United States)

    Braus, Barbara Katharina; Riedler, Daniela; Tichy, Alexander; Spergser, Joachim; Schwendenwein, Ilse

    2018-02-06

    To compare two types of bandage contact lenses on the healthy canine eye. Six healthy Beagles. Two different types of bandage contact lenses (single sized human silicone contact lens 'PureVision 2' (Bausch & Lomb Incorporated, Rochester, NY, USA) and specially designed veterinary hydrogel contact lens 'AcriVet Pat D' (Bausch & Lomb Incorporated) were placed in 12 eyes of healthy Beagle dogs. Retention times and the effects of the lenses regarding irritation of the eye, changes in tear production, impact of contact lenses on tonometric readings, and cytologic and microbiological alterations of the canine eye were investigated. Mean retention times for veterinary hydrogel lenses with special dimensions were significantly shorter (2 days) than for one size human silicon lenses (8.8 days). Irritation scores were overall low for both types of lenses apart from one human lens causing severe irritation and keratoconjunctivitis as a sequel to folding and displacement. Tear production remained stable in human contact lenses. Intraocular pressure readings with a contact lens in place were only slightly altered; the most accurate readings were obtained through a human lens with an applanation tonometer. Cytology revealed a slight, nonsignificant increase in neutrophilic granulocytes with both types of lenses; the microflora did not change significantly. Human silicone lenses have significantly longer retention times and are less expensive than veterinary hydrogel lenses. In regard to irritation, bacterial growth and inflammation, both types of lenses can be recommended for use in canine eyes. © 2018 American College of Veterinary Ophthalmologists.

  1. In the eye of the beholder: eye contact increases resistance to persuasion.

    Science.gov (United States)

    Chen, Frances S; Minson, Julia A; Schöne, Maren; Heinrichs, Markus

    2013-11-01

    Popular belief holds that eye contact increases the success of persuasive communication, and prior research suggests that speakers who direct their gaze more toward their listeners are perceived as more persuasive. In contrast, we demonstrate that more eye contact between the listener and speaker during persuasive communication predicts less attitude change in the direction advocated. In Study 1, participants freely watched videos of speakers expressing various views on controversial sociopolitical issues. Greater direct gaze at the speaker's eyes was associated with less attitude change in the direction advocated by the speaker. In Study 2, we instructed participants to look at either the eyes or the mouths of speakers presenting arguments counter to participants' own attitudes. Intentionally maintaining direct eye contact led to less persuasion than did gazing at the mouth. These findings suggest that efforts at increasing eye contact may be counterproductive across a variety of persuasion contexts.

  2. Video Conference System that Keeps Mutual Eye Contact Among Participants

    Directory of Open Access Journals (Sweden)

    Masahiko Yahagi

    2011-10-01

    Full Text Available A novel video conference system is developed. Suppose that three people A, B, and C attend the video conference, the proposed system enables eye contact among every pair. Furthermore, when B and C chat, A feels as if B and C were facing each other (eye contact seems to be kept among B and C. In the case of a triangle video conference, the respective video system is composed of a half mirror, two video cameras, and two monitors. Each participant watches other participants' images that are reflected by the half mirror. Cameras are set behind the half mirror. Since participants' image (face and the camera position are adjusted to be the same direction, eye contact is kept and conversation becomes very natural compared with conventional video conference systems where participants' eyes do not point to the other participant. When 3 participants sit at the vertex of an equilateral triangle, eyes can be kept even for the situation mentioned above (eye contact between B and C from the aspect of A. Eye contact can be kept not only for 2 or 3 participants but also any number of participants as far as they sit at the vertex of a regular polygon.

  3. Gram negative bacteria and contact lens induced acute red eye

    Directory of Open Access Journals (Sweden)

    Sankaridurg Padmaja

    1996-01-01

    Full Text Available Two patients using hydrogel contact lenses on a daily wear schedule slept overnight with the lenses and woke up with a Contact Lens Induced Acute Red Eye (CLARE. The contact lenses recovered aseptically at the time of the event grew significant colonies of Pseudomonas aeruginosa and Aeromonas hydrophila in patient A and Pseudomonas aeruginosa and Serratia liquefaciens from patient B. Similar organisams from the contact lenses were recovered from the lens case and lens care solutions of patient B. In both the patients the condition resolved on discontinuation of lens wear. Patient compliance as a requirement for successful contact lens wear is highlighted with the illustration of these cases.

  4. Absence of Preferential Unconscious Processing of Eye Contact in Adolescents With Autism Spectrum Disorder

    NARCIS (Netherlands)

    Akechi, H.; Stein, T.; Senju, A.; Kikuchi, Y.; Tojo, Y.; Osanai, H.; Hasegawa, T.

    2014-01-01

    Eye contact plays an essential role in social interaction. Atypical eye contact is a diagnostic and widely reported feature of autism spectrum disorder (ASD). Here, we determined whether altered unconscious visual processing of eye contact might underlie atypical eye contact in ASD. Using continuous

  5. Love, eye contact and the developmental origins of empathy v. psychopathy.

    Science.gov (United States)

    Dadds, Mark R; Allen, Jennifer L; Oliver, Bonamy R; Faulkner, Nathan; Legge, Katherine; Moul, Caroline; Woolgar, Matthew; Scott, Stephen

    2012-03-01

    A propensity to attend to other people's emotions is a necessary condition for human empathy. To test our hypothesis that psychopathic disorder begins as a failure to attend to the eyes of attachment figures, using a `love' scenario in young children. Children with oppositional defiant disorder, assessed for callous-unemotional traits, and a control group were observed in a love interaction with mothers. Eye contact and affection were measured for each dyad. There was no group difference in affection and eye contact expressed by the mothers. Compared with controls, children with oppositional defiant disorder expressed lower levels of affection back towards their mothers; those with high levels of callous-unemotional traits showed significantly lower levels of affection than the children lacking these traits. As predicted, the former group showed low levels of eye contact toward their mothers. Low eye contact was not correlated with maternal coercive parenting or feelings toward the child, but was correlated with psychopathic fearlessness in their fathers. Impairments in eye contact are characteristic of children with callous-unemotional traits, and these impairments are independent of maternal behaviour.

  6. Contact lens wear and dry eyes: challenges and solutions

    Directory of Open Access Journals (Sweden)

    Markoulli M

    2017-02-01

    Full Text Available Maria Markoulli, Sailesh Kolanu School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia Abstract: The number of contact lens wearers worldwide has remained relatively stable over the past decade, despite the investment that has gone into contact lens technology. This is largely because 10%–50% of wearers dropout of contact lens wear within 3 years of commencement; the most common reason cited being contact lens discomfort (CLD. Of the symptoms reported, sensation of dry eye is the most common. Given the outcome of reduced wearing time, increased chair time, and ultimate contact lens discontinuation, the challenge is to identify the warning signs of CLD early on. Clinically detectable changes such as conjunctival staining, conjunctival indentation, conjunctival epithelial flap formation, lid wiper epitheliopathy, Demodex blepharitis, and meibomian gland dysfunction have been linked to CLD, highlighting the need to perform regular aftercare visits to identify these changes. At a cellular level, conjunctival metaplasia and reduced goblet cell density have been linked to CLD, leading to a downstream effect on the tear film breakup time of contact lens wearers. These factors suggest a strong link between CLD and friction, raising the need to target this as a means of minimizing CLD. The purpose of this review is to identify the clinical signs that relate to CLD as a means of earlier detection and management in order to combat contact lens dropout. Keywords: contact lens discomfort, dry eye disease, lid wiper epitheliopathy, tear film biomarkers, meibomian gland dysfunction

  7. Genuine eye contact elicits self-referential processing.

    Science.gov (United States)

    Hietanen, Jonne O; Hietanen, Jari K

    2017-05-01

    The effect of eye contact on self-awareness was investigated with implicit measures based on the use of first-person singular pronouns in sentences. The measures were proposed to tap into self-referential processing, that is, information processing associated with self-awareness. In addition, participants filled in a questionnaire measuring explicit self-awareness. In Experiment 1, the stimulus was a video clip showing another person and, in Experiment 2, the stimulus was a live person. In both experiments, participants were divided into two groups and presented with the stimulus person either making eye contact or gazing downward, depending on the group assignment. During the task, the gaze stimulus was presented before each trial of the pronoun-selection task. Eye contact was found to increase the use of first-person pronouns, but only when participants were facing a real person, not when they were looking at a video of a person. No difference in self-reported self-awareness was found between the two gaze direction groups in either experiment. The results indicate that eye contact elicits self-referential processing, but the effect may be stronger, or possibly limited to, live interaction. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Arthropods affecting the human eye.

    Science.gov (United States)

    Panadero-Fontán, Rosario; Otranto, Domenico

    2015-02-28

    Ocular infestations by arthropods consist in the parasitization of the human eye, either directly (e.g., some insect larvae causing ophthalmomyiasis) or via arthropods feeding on lachrymal/conjunctival secretions (e.g., some eye-seeking insects, which also act as vectors of eye pathogens). In addition, demodicosis and phthiriasis may also cause eye discomfort in humans. Ophthalmomyiasis by larvae of the families Oestridae, Calliphoridae and Sarcophagidae, are frequent causative agents of human ocular infestations. Over the last decades, the extensive use of macrocyclic lactones in cattle has reduced the frequency of infestations by Hypoderma bovis and Hypoderma lineatum (family Oestridae), and consequently, human infestations by these species. A prompt diagnosis of ocular myiasis (e.g., by serological tests) is pivotal for positive prognoses, particularly when the larvae are not detectable during the ophthalmologic examination. Molecular diagnoses may also assist physicians and parasitologists in achieving time-efficient diagnoses of infestations by Oestridae causing myiasis. Finally, due to widespread international travel to exotic destinations, cases of myiasis are increasing in non-endemic areas, therefore requiring physicians to acquire a profound knowledge of the clinical symptoms linked to these infestations to prevent costly, inappropriate treatments or severe complications. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Non-contact tonometry in the postoperative eye.

    OpenAIRE

    Vernon, S A

    1989-01-01

    The Keeler Pulsair non-contact tonometer was compared with the Goldmann applanation tonometer in a series of 48 eyes after operation. A correlation coefficient of 0.92 (p less than 0.001) was found between the two instruments, with the Pulsair having a statistically significant tendency to overread the Goldmann slightly in this situation. The Pulsair was, however, shown to be effective in the identification of postoperative ocular hypertension with a high degree of sensitivity and specificity...

  10. Intact unconscious processing of eye contact in schizophrenia

    Directory of Open Access Journals (Sweden)

    Kiley Seymour

    2016-03-01

    Full Text Available The perception of eye gaze is crucial for social interaction, providing essential information about another person’s goals, intentions, and focus of attention. People with schizophrenia suffer a wide range of social cognitive deficits, including abnormalities in eye gaze perception. For instance, patients have shown an increased bias to misjudge averted gaze as being directed toward them. In this study we probed early unconscious mechanisms of gaze processing in schizophrenia using a technique known as continuous flash suppression. Previous research using this technique to render faces with direct and averted gaze initially invisible reveals that direct eye contact gains privileged access to conscious awareness in healthy adults. We found that patients, as with healthy control subjects, showed the same effect: faces with direct eye gaze became visible significantly faster than faces with averted gaze. This suggests that early unconscious processing of eye gaze is intact in schizophrenia and implies that any misjudgments of gaze direction must manifest at a later conscious stage of gaze processing where deficits and/or biases in attributing mental states to gaze and/or beliefs about being watched may play a role.

  11. Mechanistic modeling of ophthalmic drug delivery to the anterior chamber by eye drops and contact lenses.

    Science.gov (United States)

    Gause, Samuel; Hsu, Kuan-Hui; Shafor, Chancellor; Dixon, Phillip; Powell, Kristin Conrad; Chauhan, Anuj

    2016-07-01

    Ophthalmic drug for the anterior chamber diseases are delivered into tears by either eye drops or by extended release devices placed in the eyes. The instilled drug exits the eye through various routes including tear drainage into the nose through the canaliculi and transport across various ocular membranes. Understanding the mechanisms relevant to each route can be useful in predicting the dependency of ocular bioavailability on various formulation parameters, such as drug concentration, salinity, viscosity, etc. Mathematical modeling has been developed for each of the routes and validated by comparison with experiments. The individual models can be combined into a system model to predict the fraction of the instilled drug that reaches the target. This review summarizes the individual models for the transport of drugs across the cornea and conjunctiva and the canaliculi tear drainage. It also summarizes the combined tear dynamics model that can predict the ocular bioavailability of drugs instilled as eye drops. The predictions from the individual models and the combined model are in good agreement with experimental data. Both experiments and models predict that the corneal bioavailability for drugs delivered through eye drops is less than 5% due to the small area of the cornea in comparison to the conjunctiva, and the rapid clearance of the instilled solution by tear drainage. A contact lens is a natural choice for delivering drugs to the cornea due to the placement of the contact in the immediate vicinity of the cornea. The drug released by the contact towards the cornea surface is trapped in the post lens tear film for extended duration of at least 30min allowing transport of a large portion into the cornea. The model predictions backed by in vivo animal and clinical data show that the bioavailability increases to about 50% with contact lenses. This realization has encouraged considerable research towards delivering ocular drugs by contact lenses. Commercial

  12. Evaluating a Tablet Application and Differential Reinforcement to Increase Eye Contact in Children with Autism

    Science.gov (United States)

    Jeffries, Tricia; Crosland, Kimberly; Miltenberger, Raymond

    2016-01-01

    We tested the effectiveness of a tablet application and differential reinforcement to increase eye contact in 3 children with autism. The application required the child to look at a picture of a person's face and identify the number displayed in the person's eyes. Eye contact was assessed immediately after training, 1 hr after training, and in a…

  13. A Model of the Human Eye

    Science.gov (United States)

    Colicchia, G.; Wiesner, H.; Waltner, C.; Zollman, D.

    2008-01-01

    We describe a model of the human eye that incorporates a variable converging lens. The model can be easily constructed by students with low-cost materials. It shows in a comprehensible way the functionality of the eye's optical system. Images of near and far objects can be focused. Also, the defects of near and farsighted eyes can be demonstrated.

  14. Effects of Observing Eye Contact on Gaze Following in High-Functioning Autism

    NARCIS (Netherlands)

    Böckler, A.; Timmermans, B.; Sebanz, N.; Vogeley, K.; Schilbach, L.

    2014-01-01

    Observing eye contact between others enhances the tendency to subsequently follow their gaze and has been suggested to function as a social signal that adds meaning to an upcoming action or event. The present study investigated effects of observed eye contact in high-functioning autism (HFA). Two

  15. Imaging properties of the light sword optical element used as a contact lens in a presbyopic eye model.

    Science.gov (United States)

    Petelczyc, K; Bará, S; Lopez, A Ciro; Jaroszewicz, Z; Kakarenko, K; Kolodziejczyk, A; Sypek, M

    2011-12-05

    The paper analyzes the imaging properties of the light sword optical element (LSOE) applied as a contact lens to the presbyopic human eye. We performed our studies with a human eye model based on the Gullstrand parameterization. In order to quantify the discussion concerning imaging with extended depth of focus, we introduced quantitative parameters characterizing output images of optotypes obtained in numerical simulations. The quality of the images formed by the LSOE were compared with those created by a presbyopic human eye, reading glasses and a quartic inverse axicon. Then we complemented the numerical results by an experiment where a 3D scene was imaged by means of the refractive LSOE correcting an artificial eye based on the Gullstrand model. According to performed simulations and experiments the LSOE exhibits abilities for presbyopia correction in a wide range of functional vision distances.

  16. Extended release of hyaluronic acid from hydrogel contact lenses for dry eye syndrome.

    Science.gov (United States)

    Maulvi, Furqan A; Soni, Tejal G; Shah, Dinesh O

    2015-01-01

    Current dry eye treatment includes delivering comfort enhancing agents to the eye via eye drops, but low residence time of eye drops leads to low bioavailability. Frequent administration leads to incompliance in patients, so there is a great need for medical device such as contact lenses to treat dry eye. Studies in the past have demonstrated the efficacy of hyaluronic acid (HA) in the treatment of dry eyes using eye drops. In this paper, we present two methods to load HA in hydrogel contact lenses, soaking method and direct entrapment. The contact lenses were characterized by studying their optical and physical properties to determine their suitability as extended wear contact lenses. HA-laden hydrogel contact lenses prepared by soaking method showed release up to 48 h with acceptable physical and optical properties. Hydrogel contact lenses prepared by direct entrapment method showed significant sustained release in comparison to soaking method. HA entrapped in hydrogels resulted in reduction in % transmittance, sodium ion permeability and surface contact angle, while increase in % swelling. The impact on each of these properties was proportional to HA loading. The batch with 200-μg HA loading showed all acceptable values (parameters) for contact lens use. Results of cytotoxicity study indicated the safety of hydrogel contact lenses. In vivo pharmacokinetics studies in rabbit tear fluid showed dramatic increase in HA mean residence time and area under the curve with lenses in comparison to eye drop treatment. The study demonstrates the promising potential of delivering HA through contact lenses for the treatment of dry eye syndrome.

  17. A Practitioner Model for Increasing Eye Contact in Children With Autism.

    Science.gov (United States)

    Cook, Jennifer L; Rapp, John T; Mann, Kathryn R; McHugh, Catherine; Burji, Carla; Nuta, Raluca

    2017-05-01

    Although many teaching techniques for children with autism spectrum disorder (ASD) require the instructor to gain the child's eye contact prior to delivering an instructional demand, the literature contains notably few procedures that reliably produce this outcome. To address this problem, we evaluated the effects of a sequential model for increasing eye contact in children with ASD. The model included the following phases: contingent praise only (for eye contact), contingent edibles plus praise, stimulus prompts plus contingent edibles and praise, contingent video and praise, schedule thinning, and maintenance evaluations for up to 2 years. Results indicated that the procedures increased eye contact for 20 participants (one additional participant did not require consequences). For 16 participants, praise (alone) was not sufficient to support eye contact; however, high levels of eye contact were typically maintained with these participants when therapists used combined schedules of intermittent edibles or video and continuous praise. We discuss some limitations of this model and directions for future research on increasing eye contact for children with ASD.

  18. Intact unconscious processing of eye contact in schizophrenia

    NARCIS (Netherlands)

    Seymour, K.; Rhodes, G.; Stein, T.; Langdon, R.

    The perception of eye gaze is crucial for social interaction, providing essential information about another person's goals, intentions, and focus of attention. People with schizophrenia suffer a wide range of social cognitive deficits, including abnormalities in eye gaze perception. For instance,

  19. Modelling human eye under blast loading.

    Science.gov (United States)

    Esposito, L; Clemente, C; Bonora, N; Rossi, T

    2015-01-01

    Primary blast injury (PBI) is the general term that refers to injuries resulting from the mere interaction of a blast wave with the body. Although few instances of primary ocular blast injury, without a concomitant secondary blast injury from debris, are documented, some experimental studies demonstrate its occurrence. In order to investigate PBI to the eye, a finite element model of the human eye using simple constitutive models was developed. The material parameters were calibrated by a multi-objective optimisation performed on available eye impact test data. The behaviour of the human eye and the dynamics of mechanisms occurring under PBI loading conditions were modelled. For the generation of the blast waves, different combinations of explosive (trinitrotoluene) mass charge and distance from the eye were analysed. An interpretation of the resulting pressure, based on the propagation and reflection of the waves inside the eye bulb and orbit, is proposed. The peculiar geometry of the bony orbit (similar to a frustum cone) can induce a resonance cavity effect and generate a pressure standing wave potentially hurtful for eye tissues.

  20. Optical models of the human eye.

    Science.gov (United States)

    Atchison, David A; Thibos, Larry N

    2016-03-01

    Optical models of the human eye have been used in visual science for purposes such as providing a framework for explaining optical phenomena in vision, for predicting how refraction and aberrations are affected by change in ocular biometry and as computational tools for exploring the limitations imposed on vision by the optical system of the eye. We address the issue of what is understood by optical model eyes, discussing the 'encyclopaedia' and 'toy train' approaches to modelling. An extensive list of purposes of models is provided. We discuss many of the theoretical types of optical models (also schematic eyes) of varying anatomical accuracy, including single, three and four refracting surface variants. We cover the models with lens structure in the form of nested shells and gradient index. Many optical eye models give accurate predictions only for small angles and small fields of view. If aberrations and image quality are important to consider, such 'paraxial' model eyes must be replaced by 'finite model' eyes incorporating features such as aspheric surfaces, tilts and decentrations, wavelength-dependent media and curved retinas. Many optical model eyes are population averages and must become adaptable to account for age, gender, ethnicity, refractive error and accommodation. They can also be customised for the individual when extensive ocular biometry and optical performance data are available. We consider which optical model should be used for a particular purpose, adhering to the principle that the best model is the simplest fit for the task. We provide a glimpse into the future of optical models of the human eye. This review is interwoven with historical developments, highlighting the important people who have contributed so richly to our understanding of visual optics. © 2016 The Authors. Clinical and Experimental Optometry © 2016 Optometry Australia.

  1. Eye contact perception in the West and East: a cross-cultural study.

    Science.gov (United States)

    Uono, Shota; Hietanen, Jari K

    2015-01-01

    This study investigated whether eye contact perception differs in people with different cultural backgrounds. Finnish (European) and Japanese (East Asian) participants were asked to determine whether Finnish and Japanese neutral faces with various gaze directions were looking at them. Further, participants rated the face stimuli for emotion and other affect-related dimensions. The results indicated that Finnish viewers had a smaller bias toward judging slightly averted gazes as directed at them when judging Finnish rather than Japanese faces, while the bias of Japanese viewers did not differ between faces from their own and other cultural backgrounds. This may be explained by Westerners experiencing more eye contact in their daily life leading to larger visual experience of gaze perception generally, and to more accurate perception of eye contact with people from their own cultural background particularly. The results also revealed cultural differences in the perception of emotion from neutral faces that could also contribute to the bias in eye contact perception.

  2. Neurons in the monkey amygdala detect eye-contact during naturalistic social interactions

    Science.gov (United States)

    Mosher, Clayton P.; Zimmerman, Prisca E.; Gothard, Katalin M.

    2014-01-01

    Summary Primates explore the visual world through eye-movement sequences. Saccades bring details of interest into the fovea while fixations stabilize the image [1]. During natural vision, social primates direct their gaze at the eyes of others to communicate their own emotions and intentions and to gather information about the mental states of others [2]. Direct gaze is an integral part of facial expressions that signals cooperation or conflict over resources and social status [3-6]. Despite the great importance of making and breaking eye contact in the behavioral repertoire of primates, little is known about the neural substrates that support these behaviors. Here we show that the monkey amygdala contains neurons that respond selectively to fixations at the eyes of others and to eye contact. These “eye cells” share several features with the canonical, visually responsive neurons in the monkey amygdala, however, they respond to the eyes only when they fall within the fovea of the viewer, either as a result of a deliberate saccade, or as eyes move into the fovea of the viewer during a fixation intended to explore a different feature. The presence of eyes in peripheral vision fails to activate the eye cells. These findings link the primate amygdala to eye-movements involved in the exploration and selection of details in visual scenes that contain socially and emotionally salient features. PMID:25283782

  3. Neurons in the monkey amygdala detect eye contact during naturalistic social interactions.

    Science.gov (United States)

    Mosher, Clayton P; Zimmerman, Prisca E; Gothard, Katalin M

    2014-10-20

    Primates explore the visual world through eye-movement sequences. Saccades bring details of interest into the fovea, while fixations stabilize the image. During natural vision, social primates direct their gaze at the eyes of others to communicate their own emotions and intentions and to gather information about the mental states of others. Direct gaze is an integral part of facial expressions that signals cooperation or conflict over resources and social status. Despite the great importance of making and breaking eye contact in the behavioral repertoire of primates, little is known about the neural substrates that support these behaviors. Here we show that the monkey amygdala contains neurons that respond selectively to fixations on the eyes of others and to eye contact. These "eye cells" share several features with the canonical, visually responsive neurons in the monkey amygdala; however, they respond to the eyes only when they fall within the fovea of the viewer, either as a result of a deliberate saccade or as eyes move into the fovea of the viewer during a fixation intended to explore a different feature. The presence of eyes in peripheral vision fails to activate the eye cells. These findings link the primate amygdala to eye movements involved in the exploration and selection of details in visual scenes that contain socially and emotionally salient features. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Conjunctival impression cytology versus routine tear function tests for dry eye evaluation in contact lens wearers.

    Science.gov (United States)

    Kumar, Prachi; Bhargava, Rahul; Arora, Yogesh C; Kaushal, Sidharth; Kumar, Manjushri

    2015-01-01

    Prolonged contact lens wear is often accompanied by dryness of the eyes. The aim of this study was to compare conjunctival impression cytology (CIC) and tear film tests such as tear film break up time (TBUT) and Schirmer test for dry eye evaluation in contact lens wearers and measure their correlation with dry eye symptoms. A case control study was done at three referral eye centers. The eyes of 230 contact lens users were compared to 250 eyes of age- and sex-matched controls. Participants were recruited based on their response to a questionnaire of dry eye symptoms, (Dry Eye Scoring System, DESS(©)) and measurements of TBUT, Schirmer test, and CIC was done. A correlation analysis between symptom severity and tear film tests was performed. Pearson's coefficient, R(2) > 0.5 was considered significant. As compared to controls (r (2) = 0.010), Nelson grade correlated significantly with dry eye symptoms (r (2) = 0.765), among cases. However, there was moderate correlation between dry eye symptoms, Schirmer test, and TBUT (r (2) = 0.557 and 0.530, respectively) among cases and a weak correlation among controls (r (2) = 0.130 and 0.054, respectively). The sensitivity of TBUT was 86.4%, specificity was 82.4%, positive likelihood ratio (LR) was 4.50 [95% confidence interval (CI) 3.46-5.85)], and negative LR was 0.09. The sensitivity of the Schirmer test was 48.2%, specificity 88%, LR 2.12 (95% CI 1.48-2.96), and negative LR 0.83. CIC correlates better than Schirmer and TBUT with dry eye symptoms. It may be the most appropriate test for dry-eye evaluation in contact lens wearers.

  5. Oral omega-6 essential fatty acid treatment in contact lens associated dry eye.

    OpenAIRE

    Kokke, K. H.; Morris, J. A.; Lawrenson, J.

    2008-01-01

    Symptoms of dry eye are commonly reported in contact lens wearers and are a frequent cause of non-tolerance. The purpose of the present study is to evaluate the effects of oral treatment with particular omega-6 fatty acids in the form of evening primrose oil (EPO) on subjective symptoms, ocular surface signs and tear film characteristic in patients with contact lens associated dry eye.

  6. Increased Eye Contact during Conversation Compared to Play in Children with Autism

    Science.gov (United States)

    Jones, Rebecca M.; Southerland, Audrey; Hamo, Amarelle; Carberry, Caroline; Bridges, Chanel; Nay, Sarah; Stubbs, Elizabeth; Komarow, Emily; Washington, Clay; Rehg, James M.; Lord, Catherine; Rozga, Agata

    2017-01-01

    Children with autism have atypical gaze behavior but it is unknown whether gaze differs during distinct types of reciprocal interactions. Typically developing children (N = 20) and children with autism (N = 20) (4-13 years) made similar amounts of eye contact with an examiner during a conversation. Surprisingly, there was minimal eye contact…

  7. Further Evaluation of a Practitioner Model for Increasing Eye Contact in Children With Autism.

    Science.gov (United States)

    Rapp, John T; Cook, Jennifer L; Nuta, Raluca; Balagot, Carissa; Crouchman, Kayla; Jenkins, Claire; Karim, Sidrah; Watters-Wybrow, Chelsea

    2018-02-01

    Cook et al. recently described a progressive model for teaching children with autism spectrum disorder (ASD) to provide eye contact with an instructor following a name call. The model included the following phases: contingent praise only, contingent edibles plus praise, stimulus prompts plus contingent edibles and praise, contingent video and praise, schedule thinning, generalization assessments, and maintenance evaluations. In the present study, we evaluated the extent to which modifications to the model were needed to train 15 children with ASD to engage in eye contact. Results show that 11 of 15 participants acquired eye contact with the progressive model; however, eight participants required one or more procedural modifications to the model to acquire eye contact. In addition, the four participants who did not acquire eye contact received one or more modifications. Results also show that participants who acquired eye contact with or without modifications continued to display high levels of the behavior during follow-up probes. We discuss directions for future research with and limitations of this progressive model.

  8. Contact-Free Cognitive Load Recognition Based on Eye Movement

    Directory of Open Access Journals (Sweden)

    Xin Liu

    2016-01-01

    Full Text Available The cognitive overload not only affects the physical and mental diseases, but also affects the work efficiency and safety. Hence, the research of measuring cognitive load has been an important part of cognitive load theory. In this paper, we proposed a method to identify the state of cognitive load by using eye movement data in a noncontact manner. We designed a visual experiment to elicit human’s cognitive load as high and low state in two light intense environments and recorded the eye movement data in this whole process. Twelve salient features of the eye movement were selected by using statistic test. Algorithms for processing some features are proposed for increasing the recognition rate. Finally we used the support vector machine (SVM to classify high and low cognitive load. The experimental results show that the method can achieve 90.25% accuracy in light controlled condition.

  9. Contact lenses purchased over the internet place individuals potentially at risk for harmful eye care practices.

    Science.gov (United States)

    Fogel, Joshua; Zidile, Chaya

    2008-01-01

    Individuals are increasingly purchasing contact lenses over the Internet. No studies exist regarding Internet purchase of contact lenses and eye care health practices. One hundred fifty-one college students were surveyed regarding contact lenses purchase category (doctor's office, store, Internet). Pearson chi-square analyses compared purchase category with responses regarding U.S. Food and Drug Administration (FDA) recommendations for purchasing contact lenses online. Analysis of variance compared contact lenses purchase category with the Time Pressure Scale (TPS). Also, correlation analyses compared the TPS with Internet eye-health statements. Contact lens purchase categories included doctor's office (43.0%), store (55.0%), and Internet (22.5%), with individuals purchasing at multiple venues. With regard to the FDA recommendations, those who purchased contact lenses at a doctor's office more often adhered to the recommendations, whereas those who purchased contact lenses at a store or the Internet did so less often. Those who purchased contact lenses over the Internet had significantly higher TPS scores. In addition, higher TPS scores were significantly correlated with various statements regarding the Internet. Those who purchase contact lenses via the Internet or store do not follow a number of FDA contact lenses recommendations. Also, those with higher TPS scores trust possible non-evidence-based contact lenses Internet information. Implications with regard to the Fairness to Contact Lens Consumers Act are discussed.

  10. Prediction of Human Eye Fixations using Symmetry

    OpenAIRE

    Kootstra, Gert; Schomaker, Lambert R. B.

    2009-01-01

    Humans are very sensitive to symmetry in visual patterns. Reaction time experiments show that symmetry is detected and recognized very rapidly. This suggests that symmetry is a highly salient feature. Existing computational models of saliency, however, have mainly focused on contrast as a measure of saliency. In this paper, we discuss local symmetry as a measure of saliency. We propose a number of symmetry models and perform an eye-tracking study with human participants viewing photographic i...

  11. Communication Aid with Human Eyes Only

    Science.gov (United States)

    Arai, Kohei; Yajima, Kenro

    A communication aid with human eyes only is proposed. A set of candidate character is displayed onto computer screen of relatively small and light Head Mount Display: HMD that is mounted on glasses of which user wears on. When user looks at a candidate character with his/hers left eye while right eye picture is taken with small and light web camera that also is mounted on the glasses. The proposed system can selects 81 characters with two layers of 9 by 9 character candidate image. Other than these there is another selective image including control keys and frequently use of sentences. By using image matching between previously acquired template image for each candidate character and the currently acquired image, the proposed system realizes that which character in the candidates is selected. By using blinking and fix one's eye on combine together, the proposed system recognizes that user determines the selected key from the candidates. The blinking detection method employs a morphologic filter to avoid misunderstanding of dark eye detection due to eyebrows and shadows. Thus user can input sentences. User also may edit the sentences and then the sentences are read with Text to Speech: TTS software tool. Thus the system allows support conversations between handicapped and disabled persons without voice and the others peoples because only the function required for conversation is human eyes. Also the proposed system can be used as an input system for wearable computing systems. Test results by the 6 different able persons show that the proposed system does work with acceptable speed, around 1.5 second / character.

  12. Dry Eye Treatment Based on Contact Lens Drug Delivery: A Review.

    Science.gov (United States)

    Guzman-Aranguez, Ana; Fonseca, Begoña; Carracedo, Gonzalo; Martin-Gil, Alba; Martinez-Aguila, Alejandro; Pintor, Jesús

    2016-09-01

    Dry eye disease affects a substantial segment of the word population with increasing frequency. It is a multifactorial disease of the ocular surface and tear film, which causes ocular discomfort, visual disturbances, and tear instability with potential damage to the cornea and conjunctiva. Because of its multifactorial etiology, the use of different pharmacological treatment for dry eye treatment has been proposed, which include anti-inflammatory molecules, lubricants or comfort agents, and secretagogues. However, in some cases these pharmacological approaches only relieve symptoms temporarily, and consequently, eye care professionals continue to have difficulties managing dry eye. To improve pharmacological therapy that allows a more efficient and long-term action, effective ocular drug delivery of the currently available drugs for dry eye treatment is required. Contact lenses are emerging as alternative ophthalmic drugs delivery systems that provide an increased residence time of the drug at the eye, thus leading to enhanced bioavailability and more convenient and efficacious therapy. In this article, we reviewed the different techniques used to prepare contact lens-based drug delivery systems and focused on articles that describe the delivery of compounds for dry eye treatment through contact lenses.

  13. Treatment, material, care, and patient-related factors in contact lens-related dry eye.

    Science.gov (United States)

    Ramamoorthy, Padmapriya; Sinnott, Loraine T; Nichols, Jason J

    2008-08-01

    To examine the effect of general contact lens and material characteristics, care solutions, treatment, and patient-related factors on contact lens-related dry eye. The data were derived from the Contact Lens and Dry Eye Study, designed as a cross-sectional and nested case-control study including 360 subjects. In separate statistical models, logistic regression was used to examine general contact lens characteristics, specific hydrogel lens materials, care solutions, and patient-related factors associated with dry eye status (controlled for age, gender, and current treatments). Several factors were significantly associated with dry eye, including treatment factors such as a recent contact lens refitting (odds ratios [OR] = 5.75, 95% confidence intervals [CI] = 2.14 to 15.46) and use of artificial tears/rewetting drops (OR = 1.09, 95% CI = 1.02 to 1.16), in addition, currently worn materials including Food and Drug Administration (FDA) group II (OR = 2.98, 95% CI = 1.14 to 6.19) and IV (OR = 1.87, 95% CI = 1.08 to 3.24). Significant patient-related factors included decreased overall satisfaction (OR = 3.57, 95% CI = 2.08 to 5.88,), dry eye in the absence of contact lens wear (OR = 6.54, 95% CI = 2.57 to 16.62), reduced daily lens wear duration (OR = 1.16, 95% CI = 1.06 to 1.26), and reduced ability to wear lenses as long as desired (OR = 2.44, 95% CI = 1.30 to 4.54). Care solutions were not associated with contact lens-related dry eye. The strong association of common treatment factors with dry eye status in contact lens wearers suggests that these treatments are not entirely effective. The use of high water content materials was strongly related to dry eye in lens wearers, whereas care solutions were not. Contact lens-related dry eye was also associated with several patient-related factors such as greater ocular discomfort (without lenses), dissatisfaction, and inability to wear lenses for desired durations.

  14. Zoonotic helminths affecting the human eye

    Science.gov (United States)

    2011-01-01

    Nowaday, zoonoses are an important cause of human parasitic diseases worldwide and a major threat to the socio-economic development, mainly in developing countries. Importantly, zoonotic helminths that affect human eyes (HIE) may cause blindness with severe socio-economic consequences to human communities. These infections include nematodes, cestodes and trematodes, which may be transmitted by vectors (dirofilariasis, onchocerciasis, thelaziasis), food consumption (sparganosis, trichinellosis) and those acquired indirectly from the environment (ascariasis, echinococcosis, fascioliasis). Adult and/or larval stages of HIE may localize into human ocular tissues externally (i.e., lachrymal glands, eyelids, conjunctival sacs) or into the ocular globe (i.e., intravitreous retina, anterior and or posterior chamber) causing symptoms due to the parasitic localization in the eyes or to the immune reaction they elicit in the host. Unfortunately, data on HIE are scant and mostly limited to case reports from different countries. The biology and epidemiology of the most frequently reported HIE are discussed as well as clinical description of the diseases, diagnostic considerations and video clips on their presentation and surgical treatment. Homines amplius oculis, quam auribus credunt Seneca Ep 6,5 Men believe their eyes more than their ears PMID:21429191

  15. Zoonotic helminths affecting the human eye

    Directory of Open Access Journals (Sweden)

    Eberhard Mark L

    2011-03-01

    Full Text Available Abstract Nowaday, zoonoses are an important cause of human parasitic diseases worldwide and a major threat to the socio-economic development, mainly in developing countries. Importantly, zoonotic helminths that affect human eyes (HIE may cause blindness with severe socio-economic consequences to human communities. These infections include nematodes, cestodes and trematodes, which may be transmitted by vectors (dirofilariasis, onchocerciasis, thelaziasis, food consumption (sparganosis, trichinellosis and those acquired indirectly from the environment (ascariasis, echinococcosis, fascioliasis. Adult and/or larval stages of HIE may localize into human ocular tissues externally (i.e., lachrymal glands, eyelids, conjunctival sacs or into the ocular globe (i.e., intravitreous retina, anterior and or posterior chamber causing symptoms due to the parasitic localization in the eyes or to the immune reaction they elicit in the host. Unfortunately, data on HIE are scant and mostly limited to case reports from different countries. The biology and epidemiology of the most frequently reported HIE are discussed as well as clinical description of the diseases, diagnostic considerations and video clips on their presentation and surgical treatment. Homines amplius oculis, quam auribus credunt Seneca Ep 6,5 Men believe their eyes more than their ears

  16. Theoretical investigation of aberrations upon ametropic human eyes

    Science.gov (United States)

    Tan, Bo; Chen, Ying-Ling; Lewis, J. W. L.; Baker, Kevin

    2003-11-01

    The human eye aberrations are important for visual acuity and ophthalmic diagnostics and surgical procedures. Reported monochromatic aberration data of the normal 20/20 human eyes are scarce. There exist even fewer reports of the relation between ametropic conditions and aberrations. We theoretically investigate the monochromatic and chromatic aberrations of human eyes for refractive errors of -10 to +10 diopters. Schematic human eye models are employed using optical design software for axial, index, and refractive types of ametropia.

  17. Use of Contact Lenses in Eyes with Severe Keratoconus: Long-term Results

    Directory of Open Access Journals (Sweden)

    Zerrin Tuncer

    2012-05-01

    Full Text Available Pur po se: To evaluate the long-term results of rigid gas permeable (RGP contact lenses in severe keratoconic eyes. Ma te ri al and Met hod: Severe keratoconic eyes with RGP contact lenses were evaluated retrospectively. Re sults: Long-term follow-up results of RGP contact lenses applied to 59 eyes of 42 patients (25 women, 17 men with a diagnosis of severe keratoconus were analyzed. Follow-up period was 3 to 12 years (mean: 6.57±3.60. The mean age at first exam was 25.88±9.10 years, the mean corneal curve K1 was 6.49±0.40 mm and K2 was 5.91±0.40 mm. Mean visual acuities with spectacles and contact lenses were 0.26±0.10 lines (0.63±0.20 logMAR and 0.66±0.20 lines (0.20±0.10 logMAR, respectively. The difference between both visual acuities was statistically significant (p=0.0001. At the last visit, the mean visual acuity with RGP contact lenses was 0.68±0.20 lines (0.19±0.10 logMAR. There was no statistically significant difference in visual acuity between first and last examinations with contact lenses (p=0.32. During the long-term follow-up period, apical scarring developed in 17 eyes. Only the 2 eyes of one patient needed penetrating keratoplasty after 6 years of RGP contact lens use. Dis cus si on: Use of RGP contact lenses should be considered before penetrating keratoplasty in cases of severe keratoconus. (Turk J Ophthalmol 2012; 42: 202-6

  18. Oral omega-6 essential fatty acid treatment in contact lens associated dry eye.

    Science.gov (United States)

    Kokke, Karolien H; Morris, Judith A; Lawrenson, John G

    2008-06-01

    Symptoms of dry eye are commonly reported in contact lens wearers and are a frequent cause of non-tolerance. The purpose of the present study is to evaluate the effects of oral treatment with particular omega-6 fatty acids in the form of evening primrose oil (EPO) on subjective symptoms, ocular surface signs and tear film characteristic in patients with contact lens associated dry eye. The study design was randomised, double-masked and placebo controlled. 76 female soft contact lens wearers were treated for 6 months with either EPO or placebo (olive oil). Subjects underwent three examinations (baseline, 3 and 6 months). At each examination subjects were given a questionnaire relating to lens comfort and dry eye symptoms and underwent a series of tests of tear film characteristics (tear meniscus height, break-up time), meibomian gland function (lipid layer thickness and quality) and ocular surface parameters (hyperaemia and staining). The EPO group showed a significant improvement in the specific symptom of 'dryness' at 3 and 6 months (porally administered omega-6 fatty acids in alleviating dry eye symptoms and improving overall lens comfort in patients suffering from contact lens associated dry eye.

  19. The Management of Refractory Dry Eye With Semi-Scleral Contact Lens.

    Science.gov (United States)

    Yuksel, Erdem; Bilgihan, Kamil; Novruzlu, Şahin; Yuksel, Nilay; Koksal, Murat

    2016-05-19

    We presented a case of refractory dry eye management with semi-scleral contact lens. Dry eye was associated with facial nerve (cranial nerve VII) palsy as a result of cerebellopontine angle tumor surgery. She was treated with several topical treatments and punctal plug. Despite the treatments, her symptoms still persisted. Her ophthalmic examination revealed scleral exposure because of lagophthalmos, conjunctival hyperemia, corneal debris, scar, and diffuse punctate epitheliopathy on her right eye. Lissamine green staining showed diffuse conjunctival and corneal staining. Therapeutic semi-scleral lenses were fitted. The corneal findings were resolved and the quality of patient life was improved with the aid of semi-scleral lens after 3 months.

  20. On- and off-eye spherical aberration of soft contact lenses and consequent changes of effective lens power.

    Science.gov (United States)

    Dietze, Holger H; Cox, Michael J

    2003-02-01

    Soft contact lenses produce a significant level of spherical aberration affecting their power on-eye. A simple model assuming that a thin soft contact lens aligns to the cornea predicts that these effects are similar on-eye and off-eye. The wavefront aberration for 17 eyes and 33 soft contact lenses on-eye was measured with a Shack-Hartmann wavefront sensor. The Zernike coefficients describing the on-eye spherical aberration of the soft contact lens were compared with off-eye ray-tracing results. Paraxial and effective lens power changes were determined. The model predicts the on-eye spherical aberration of soft contact lenses closely. The resulting power change for a +/- 7.00 D spherical soft contact lens is +/- 0.5 D for a 6-mm pupil diameter and +/- 0.1 D for a 3-mm pupil diameter. Power change is negligible for soft contact lenses corrected for off-eye spherical aberration. For thin soft contact lenses, the level of spherical aberration and the consequent power change is similar on-eye and off-eye. Soft contact lenses corrected for spherical aberration in air will be expected to be aberration-free on-eye and produce only negligibly small power changes. For soft contact lenses without aberration correction, for higher levels of ametropia and large pupils, the soft contact lens power should be determined with trial lenses with their power and p value similar to the prescribed lens. The benefit of soft contact lenses corrected for spherical aberration depends on the level of ocular spherical aberration.

  1. Conjunctival impression cytology evaluation of patients with dry eye disease using scleral contact lenses.

    Science.gov (United States)

    Weber, Sarah La Porta; Hazarbassanov, Rossen Mihaylov; Nasaré, Alex; Gomes, José Álvaro Pereira; Hofling-Lima, Ana Luisa

    2017-06-01

    To evaluate conjunctival impression cytology and HLADR expression changes after wearing scleral contact lenses (ScCLs) for moderate to severe dry eye disease (DED). Prospective interventional case series. Forty-one eyes from 25 patients with moderate to severe DED were evaluated for Esclera ScCL treatment. Best-corrected visual acuity (BCVA) and slit-lamp findings were assessed. Impression cytology specimens were obtained from DED patients at the baseline and after wearing ScCLs for 12 months. The impression cytology specimens were analyzed using morphological results score, and HLA-DR positive cells were detected and quantified. The values were compared to assess the IC changes after wearing ScCLs. Forty-one eyes from 25 patients were fitted with ScCLs to manage DED. The underlying diseases were Stevens-Johnson syndrome (22 eyes), Sjogren's syndrome (11 eyes), graft-versus-host disease (2 eyes), dry eye after keratomileusis (2 eyes) and undifferentiated ocular surface disease (4 eyes). The HE-PAS impression cytology score did not differ significantly before and after wearing ScCLs for 12 months in DED patients (p>0.05). The percentage of eyes expressing the HLA-DR antigen in the temporal conjunctiva after wearing ScCL for 12 months significantly increased in patients with Sjogren's syndrome (11.11% to 66.66%; p=0.0498). In groups with Stevens Johnson syndrome and other ocular surface disorders, we did not observe statistically significant differences (p>0.05). The ScCLs did not change the parameters used to evaluate inflammatory processes, which were measured using conjunctival impression cytology and HLA-DR expression, except in Sjogren syndrome, in which there was an unexpected increase in HLA expression. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  2. Therapeutic efficiency of sodium hyaluronate eye drops on dry eye in juvenile with myopia wearing rigid gas permeable contact lens

    Directory of Open Access Journals (Sweden)

    Bin Zhang

    2016-03-01

    Full Text Available AIM:To investigate the therapeutic efficiency of preservative-free sodium hyaluronate eye drops on dry eye in juvenile myopia wearing rigid gas permeable contact lens(RGP.METHODS:Ninety cases with dry eye related to wearing RGP in juvenile with myopia from January to May 2015 were selected. The patients aged 12.75±4.15 years old,with diopter of -3.50±1.50D as spherical equivalent and received normalized RGP. They were divided into 3 groups randomly,each group of 30 cases(60 eyes:group A used rewetting drops,1 drop each time,4 times per day; group B used preservative-free sodium hyaluronate eye drops(1g/L,1 drop each time,4 times per day; group C used rewetting drops at first, then sodium hyaluronate eye drops was used 15 minutes later.All cases had been detected and evaluated by subjective symptoms of dry eye,Schirmer I test(SⅠt,break-up time(BUTand corneal fluorescent staining,at pre-therapy and 1, 2, 4wk of post-therapy.RESULTS:The subjective symptoms of dry eye,corneal fluorescent staining and BUT of three groups had been obviously improved at 1wk after therapies than those before therapies(PP>0.05.Every index of the three groups measured at 2 and 4wk after treatments had no significant differences compared to those measured at 1wk(P>0.05.There was no significant difference on subjective symptoms,SⅠt and BUT between group A and B(P>0.05,except on corneal fluorescent staining, on which group B was superior to group A and on which the difference was significant(PPPCONCLUSION:Preservative-free sodium hyaluronate eye drops(1g/Lcan stabilize the tear film and promote the repair of corneal epithelial defects and significantly improve dry eye symptoms and signs in juvenile myopia wearing RGP,so it has certain clinical application value.

  3. Higher order monochromatic aberrations of the human infant eye

    OpenAIRE

    Wang, Jingyun; Candy, T. Rowan

    2005-01-01

    The monochromatic optical aberrations of the eye degrade retinal image quality. Any significant aberrations during postnatal development could contribute to infants’ immature visual performance and provide signals for the control of eye growth. Aberrations of human infant eyes from 5 to 7 weeks old were compared with those of adult subjects using a model of an adultlike infant eye that accounted for differences in both eye and pupil size. Data were collected using the COAS Shack-Hartmann wave...

  4. Impact of Video Feedback on Teachers' Eye-Contact Mannerisms in Microteaching.

    Science.gov (United States)

    Karasar, Niyazi

    To test the impact of video feedback on teachers' eye-contact mannerisms in microteaching in inservice vocational teacher education, the study utilized video recordings from the data bank generated by previous studies conducted at the Ohio State University's Center for Vocational and Technical Education. The tapes were assigned through a…

  5. Eye contact perception in the West and East: a cross-cultural study.

    Directory of Open Access Journals (Sweden)

    Shota Uono

    Full Text Available This study investigated whether eye contact perception differs in people with different cultural backgrounds. Finnish (European and Japanese (East Asian participants were asked to determine whether Finnish and Japanese neutral faces with various gaze directions were looking at them. Further, participants rated the face stimuli for emotion and other affect-related dimensions. The results indicated that Finnish viewers had a smaller bias toward judging slightly averted gazes as directed at them when judging Finnish rather than Japanese faces, while the bias of Japanese viewers did not differ between faces from their own and other cultural backgrounds. This may be explained by Westerners experiencing more eye contact in their daily life leading to larger visual experience of gaze perception generally, and to more accurate perception of eye contact with people from their own cultural background particularly. The results also revealed cultural differences in the perception of emotion from neutral faces that could also contribute to the bias in eye contact perception.

  6. Blink patterns and lid-contact times in dry-eye and normal subjects

    Directory of Open Access Journals (Sweden)

    Ousler GW 3rd

    2014-05-01

    Full Text Available George W Ousler 3rd,1 Mark B Abelson,1,2 Patrick R Johnston,1 John Rodriguez,1 Keith Lane,1 Lisa M Smith11Ora, Andover, MA, USA; 2Department of Ophthalmology, Harvard Medical School, Boston, MA, USAPurpose: To classify blinks in dry eye and normal subjects into six subtypes, and to define the blink rate and duration within each type of blink, as well as the total lid-contact time/minute.Materials and methods: This was a single-centered, prospective, double-blind study of eleven dry-eye and ten normal subjects. Predefined subjects watched a video while blinks were recorded for 10 minutes. Partial blinks were classified by percentage closure of maximal palpebral fissure opening: 25%, 50%, 75%. Complete blinks were characterized as full (>0 seconds, extended (>0.1 seconds, or superextended (>0.5 seconds. The mean duration of each type of blink was determined and standardized per minute as total lid-contact time.Results: Total blinks observed were 4,990 (1,414 normal, 3,756 dry eye: 1,809 (50.59% partial and 1,767 (49.41% complete blinks among dry-eye subjects versus 741 (52.90% partial and 673 (47.60% complete blinks among normal subjects. Only superextended blinks of ≥0.5-second duration were significantly more frequent in dry-eye subjects than normals (2.3% versus 0.2%, respectively; P=0.023. Total contact time was seven times higher in dry-eye subjects than normals (0.565 versus 0.080 seconds, respectively; P<0.001. Isolating only extended blinks (>0.1 second, the average contact time (seconds was four times longer in dry-eye versus normal subjects (2.459 in dry eye, 0.575 in normals; P=0.003. Isolating only superextended blinks (>0.5 seconds, average contact time was also significantly different (7.134 in dry eye, 1.589 in normals; P<0.001. The contact rate for all full closures was 6.4 times longer in dry-eye (0.045 versus 0.007, P<0.001 than normal subjects.Conclusion: Dry-eye subjects spent 4.5% of a

  7. Cyclooxygenase-2 expression in the normal human eye and its expression pattern in selected eye tumours

    DEFF Research Database (Denmark)

    Wang, Jinmei; Wu, Yazhen; Heegaard, Steffen

    2011-01-01

    Purpose: Cyclooxygenase-2 (COX-2) is an enzyme involved in neoplastic processes. The purpose of the present study is to investigate COX-2 expression in the normal human eye and the expression pattern in selected eye tumours involving COX-2 expressing cells. Methods: Immunohistochemical staining...... using antibodies against COX-2 was performed on paraffin sections of normal human eyes and selected eye tumours arising from cells expressing COX-2. Results: Cyclooxygenase-2 expression was found in various structures of the normal eye. Abundant expression was seen in the cornea, iris, ciliary body...... and retina. The COX-2 expression was less in tumours deriving from the ciliary epithelium and also in retinoblastoma. Conclusion: Cyclooxygenase-2 is constitutively expressed in normal human eyes. The expression of COX-2 is much lower in selected eye tumours involving COX-2 expressing cells....

  8. Oral omega-3 fatty acid treatment for dry eye in contact lens wearers.

    Science.gov (United States)

    Bhargava, Rahul; Kumar, Prachi

    2015-04-01

    The aim of this study was to evaluate the effect of dietary omega-3 fatty acid (O3FA) supplementation on dry eye symptoms, tear film tests, and conjunctival impression cytology in patients with contact lens wear-associated dry eye. In this randomized, double-blind, multicentric trial, contact lens wearers (n = 496) were randomized to receive either O3FAs or placebo capsules (corn oil) twice daily for 6 months. Subjects underwent examinations at baseline, 3 months, and 6 months. At each visit, a questionnaire of dry eye symptoms and lens wear comfort was administered. Subjects further underwent measurement of tear film break-up time (TBUT) and a Schirmer test. Conjunctival impression cytology was performed by the transfer method. Improvement in symptoms and lens wear comfort were primary outcome measures. Changes from baseline in TBUT, Schirmer, and Nelson grade at 6 months were secondary outcome measures. The mean improvement in symptom score in the O3FA group was 4.7 ± 2 (2.0) as compared with 0.5 ± 2 (0.9) in the placebo group (P dry eye symptoms, improving lens wear comfort, and cytological changes in contact lens wearers.

  9. Diquafosol Ophthalmic Solution Increases Pre- and Postlens Tear Film During Contact Lens Wear in Rabbit Eyes.

    Science.gov (United States)

    Nagahara, Yukiko; Koh, Shizuka; Oshita, Yoshihiro; Nagano, Takashi; Mano, Hidetoshi; Nishida, Kohji; Watanabe, Hitoshi

    2017-11-01

    To investigate the behavior of prelens tear film (PLTF) and postlens tear film (PoLTF) after the instillation of diquafosol using an experimental rabbit model of eyes with contact lens. Cross-sectional, anterior segment optical coherence tomographic images of the inferior midperipheral cornea were obtained at baseline and at 5, 15, 30, 60, 90, and 120 min after the instillation of 3% diquafosol ophthalmic solution in 10 Japanese white rabbits wearing contact lenses. From the obtained images, the areas of the PLTF and PoLTF were calculated. Both artificial tear solution and 0.1% sodium hyaluronate ophthalmic solution were used for comparison. Significant fluid accumulation in both the PLTF and PoLTF was observed after diquafosol instillation, whereas no fluid accumulation was visible after the instillation of artificial tear or sodium hyaluronate. The increase in PLTF area after diquafosol instillation was significantly higher (Pophthalmic solution increases PLTF and PoLTF in rabbit eyes with contact lenses. Diquafosol has potential as a treatment option for contact lens-related dry eye.

  10. Relations among Social Anxiety, Eye Contact Avoidance, State Anxiety, and Perception of Interaction Performance during a Live Conversation.

    Science.gov (United States)

    Howell, Ashley N; Zibulsky, Devin A; Srivastav, Akanksha; Weeks, Justin W

    2016-01-01

    There is building evidence that highly socially anxious (HSA) individuals frequently avoid making eye contact, which may contribute to less meaningful social interactions and maintenance of social anxiety symptoms. However, research to date is lacking in ecological validity due to the usage of either static or pre-recorded facial stimuli or subjective coding of eye contact. The current study examined the relationships among trait social anxiety, eye contact avoidance, state anxiety, and participants' self-perceptions of interaction performance during a live, four-minute conversation with a confederate via webcam, and while being covertly eye-tracked. Participants included undergraduate women who conversed with same-sex confederates. Results indicated that trait social anxiety was inversely related to eye contact duration and frequency averaged across the four minutes, and positively related to state social anxiety and negative self-ratings. In addition, greater anticipatory state anxiety was associated with reduced eye contact throughout the first minute of the conversation. Eye contact was not related to post-task state anxiety or self-perception of poor performance; although, trends emerged in which these relations may be positive for HSA individuals. The current findings provide enhanced support for the notion that eye contact avoidance is an important feature of social anxiety.

  11. Release of Fluconazole from Contact Lenses Using a Novel In Vitro Eye Model.

    Science.gov (United States)

    Phan, Chau-Minh; Bajgrowicz, Magdalena; Gao, Huayi; Subbaraman, Lakshman N; Jones, Lyndon W

    2016-04-01

    Rapid drug release followed by a plateau phase is a common observation with drug delivery from contact lenses (CLs) when evaluated in a vial. The aim of this study was to compare the release of fluconazole from seven commercially available daily disposable CLs using a conventional vial-based method with a novel in vitro eye model. An eye model was created using two 3-dimensional printed molds, which were filled with polydimethylsiloxane to obtain an inexpensive model that would mimic the eyeball and eyelid. The model was integrated with a microfluidic syringe pump, and the flow-through was collected in a 12-well microliter plate. Four commercial daily disposable conventional hydrogels (nelfilcon A, omafilcon A, etafilcon A, ocufilcon B) and three silicone hydrogels (somofilcon A, narafilcon A, delefilcon A) were evaluated. These CLs were incubated with fluconazole for 24 h. The drug release was measured in a vial containing 4.8 mL of phosphate-buffered saline and in the polydimethylsiloxane eye model with a 4.8-mL tear flow across 24 h. Overall, conventional hydrogel CLs had a higher uptake and release of fluconazole than silicone hydrogel CLs (p eye model (p eye model under low tear volume was sustained and did not reach a plateau across 24 h (p eyes with fungal keratitis may have increased tearing, which would significantly accelerate drug release.

  12. Virtual pharmacokinetic model of human eye.

    Science.gov (United States)

    Kotha, Sreevani; Murtomäki, Lasse

    2014-07-01

    A virtual pharmacokinetic 3D model of the human eye is built using Comsol Multiphysics® software, which is based on the Finite Element Method (FEM). The model considers drug release from a polymer patch placed on sclera. The model concentrates on the posterior part of the eye, retina being the target tissue, and comprises the choroidal blood flow, partitioning of the drug between different tissues and active transport at the retina pigment epithelium (RPE)-choroid boundary. Although most straightforward, in order to check the mass balance, no protein binding or metabolism is yet included. It appeared that the most important issue in obtaining reliable simulation results is the finite element mesh, while time stepping has hardly any significance. Simulations were extended to 100,000 s. The concentration of a drug is shown as a function of time at various points of retina, as well as its average value, varying several parameters in the model. This work demonstrates how anybody with basic knowledge of calculus is able to build physically meaningful models of quite complex biological systems. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Eye Contact and Fear of Being Laughed at in a Gaze Discrimination Task

    Directory of Open Access Journals (Sweden)

    Jorge Torres-Marín

    2017-11-01

    Full Text Available Current approaches conceptualize gelotophobia as a personality trait characterized by a disproportionate fear of being laughed at by others. Consistently with this perspective, gelotophobes are also described as neurotic and introverted and as having a paranoid tendency to anticipate derision and mockery situations. Although research on gelotophobia has significantly progressed over the past two decades, no evidence exists concerning the potential effects of gelotophobia in reaction to eye contact. Previous research has pointed to difficulties in discriminating gaze direction as the basis of possible misinterpretations of others’ intentions or mental states. The aim of the present research was to examine whether gelotophobia predisposition modulates the effects of eye contact (i.e., gaze discrimination when processing faces portraying several emotional expressions. In two different experiments, participants performed an experimental gaze discrimination task in which they responded, as quickly and accurately as possible, to the eyes’ directions on faces displaying either a happy, angry, fear, neutral, or sad emotional expression. In particular, we expected trait-gelotophobia to modulate the eye contact effect, showing specific group differences in the happiness condition. The results of Study 1 (N = 40 indicated that gelotophobes made more errors than non-gelotophobes did in the gaze discrimination task. In contrast to our initial hypothesis, the happiness expression did not have any special role in the observed differences between individuals with high vs. low trait-gelotophobia. In Study 2 (N = 40, we replicated the pattern of data concerning gaze discrimination ability, even after controlling for individuals’ scores on social anxiety. Furthermore, in our second experiment, we found that gelotophobes did not exhibit any problem with identifying others’ emotions, or a general incorrect attribution of affective features, such as valence

  14. Design of retinal-projection-based near-eye display with contact lens.

    Science.gov (United States)

    Wu, Yuhang; Chen, Chao Ping; Mi, Lantian; Zhang, Wenbo; Zhao, Jingxin; Lu, Yifan; Guo, Weiqian; Yu, Bing; Li, Yang; Maitlo, Nizamuddin

    2018-04-30

    We propose a design of a retinal-projection-based near-eye display for achieving ultra-large field of view, vision correction, and occlusion. Our solution is highlighted by a contact lens combo, a transparent organic light-emitting diode panel, and a twisted nematic liquid crystal panel. Its design rules are set forth in detail, followed by the results and discussion regarding the field of view, angular resolution, modulation transfer function, contrast ratio, distortion, and simulated imaging.

  15. What affects social attention? Social presence, eye contact and autistic traits.

    Directory of Open Access Journals (Sweden)

    Megan Freeth

    Full Text Available Social understanding is facilitated by effectively attending to other people and the subtle social cues they generate. In order to more fully appreciate the nature of social attention and what drives people to attend to social aspects of the world, one must investigate the factors that influence social attention. This is especially important when attempting to create models of disordered social attention, e.g. a model of social attention in autism. Here we analysed participants' viewing behaviour during one-to-one social interactions with an experimenter. Interactions were conducted either live or via video (social presence manipulation. The participant was asked and then required to answer questions. Experimenter eye-contact was either direct or averted. Additionally, the influence of participant self-reported autistic traits was also investigated. We found that regardless of whether the interaction was conducted live or via a video, participants frequently looked at the experimenter's face, and they did this more often when being asked a question than when answering. Critical differences in social attention between the live and video interactions were also observed. Modifications of experimenter eye contact influenced participants' eye movements in the live interaction only; and increased autistic traits were associated with less looking at the experimenter for video interactions only. We conclude that analysing patterns of eye-movements in response to strictly controlled video stimuli and natural real-world stimuli furthers the field's understanding of the factors that influence social attention.

  16. Aquaporins 6-12 in the human eye

    DEFF Research Database (Denmark)

    Tran, Thuy Linh; Bek, Toke; Holm, Lars

    2012-01-01

    Purpose: Aquaporins (AQPs) are widely expressed and have diverse distribution patterns in the eye. AQPs 0-5 have been localized at the cellular level in human eyes. We investigated the presence of the more recently discovered AQPs 6-12 in the human eye. Methods: RT-PCR was performed on fresh tissue...... from two human eyes divided into the cornea, corneal limbus, ciliary body and iris, lens, choroid, optic nerve, retina and sclera. Each structure was examined to detect the mRNA of AQPs 6-12. Twenty-one human eyes were examined using immunohistochemical and immunofluorescence techniques to determine...... was detected in the corneal epithelium, corneal endothelium, trabecular meshwork endothelium, ciliary epithelia, lens epithelium, the inner and outer limiting membrane of the retina, the retinal pigment epithelium and the capillary endothelium of all parts of the eye. AQP9 immunolabelling was detected...

  17. Corneal confocal microscopy and dry eye findings in contact lens discomfort patients.

    Science.gov (United States)

    Dogan, Aysun Sanal; Gurdal, Canan; Arslan, Nese

    2018-02-01

    To evaluate the corneal confocal microscopy and dry eye findings in patients with contact lens discomfort. The study included 3 groups of participants: Contact lens wearers using silicone hydrogel soft contact lenses who are symptomatic (CLD, n=15) or asymptomatic (ACL, n=11) and non-wearers as controls (n=14). Duration of contact lens wear, Ocular Surface Disease Index (OSDI) questionnaire responses, fluorescein tear break-uptime (FBUT), and corneal confocal microscopy findings were recorded. Mean age was 25.7±8.2 years and male/female ratio was 7/33. Demographic findings were similar regarding the groups. CLD patients had a longer lens use history than ACL (median 5 vs 2 years, pCLD group than ACL or controls (pCLD group, compared to controls and ACL (pCLD group compared to controls but similar to ACL (pCLD group than the ACL (p=0.014). Patients with CLD had been wearing contact lenses for longer than those without symptoms. OSDI and FBUT scores were worse in CLD patients. In contact lens discomfort patients, there were increased dendritiform cells, indicating intensified inflammatory status of the cornea. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  18. Determination of positions of optical elements of the human eye

    International Nuclear Information System (INIS)

    Galetskii, S O; Cherezova, T Yu

    2009-01-01

    An original method for noninvasive determining the positions of elements of intraocular optics is proposed. The analytic dependence of the measurement error on the optical-scheme parameters and the restriction in distance from the element being measured are determined within the framework of the method proposed. It is shown that the method can be efficiently used for determining the position of elements in the classical Gullstrand eye model and personalised eye models. The positions of six optical surfaces of the Gullstrand eye model and four optical surfaces of the personalised eye model can be determined with an error of less than 0.25 mm. (human eye optics)

  19. Callous-unemotional traits in children and mechanisms of impaired eye contact during expressions of love: a treatment target?

    Science.gov (United States)

    Dadds, Mark R; Allen, Jennifer L; McGregor, Kimberley; Woolgar, Matthew; Viding, Essi; Scott, Stephen

    2014-07-01

    We previously hypothesised that the early development of psychopathy is associated with a failure to attend to the eyes of attachment figures, and we have presented preliminary data from a parent-child 'love' scenario in support of this. Here, we confirm the association in a larger sample and test mechanisms of impaired eye contact during expressions of love in control and behaviourally disturbed children. Oppositional defiant disorder children, assessed for callous-unemotional (CU) traits, and controls, were observed in a brief interaction task where the mother was asked to show love to her child. Eye contact and affection were measured for each dyad. As predicted, there were no group differences in affection and eye contact expressed by mothers; levels of CU traits predicted low levels of eye contact towards their mothers across all groups of children. As expected, low eye contact was correlated with psychopathic fearlessness in their fathers, and maternal reports of negative feelings towards the child. Independent observations showed that child's behaviour largely drives the low eye contact associated with CU traits, and low eye contact was not associated with independent observations of the quality of attachment-related behaviours in mothers. Impaired eye contact is a unique characteristic of children with CU traits; these impairments are largely independent of maternal behaviour, but associated with psychopathic traits in the fathers. These impairments should be tested for functional significance and amenability to change in longitudinal and treatment studies. © 2013 The Authors. Journal of Child Psychology and Psychiatry © 2013 Association for Child and Adolescent Mental Health.

  20. Gamma crystallins of the human eye lens.

    Science.gov (United States)

    Vendra, Venkata Pulla Rao; Khan, Ismail; Chandani, Sushil; Muniyandi, Anbukkarasi; Balasubramanian, Dorairajan

    2016-01-01

    Protein crystallins co me in three types (α, β and γ) and are found predominantly in the eye, and particularly in the lens, where they are packed into a compact, plastic, elastic, and transparent globule of proper refractive power range that aids in focusing incoming light on to the retina. Of these, the γ-crystallins are found largely in the nuclear region of the lens at very high concentrations (>400 mg/ml). The connection between their structure and inter-molecular interactions and lens transparency is an issue of particular interest. We review the origin and phylogeny of the gamma crystallins, their special structure involving the use of Greek key supersecondary structural motif, and how they aid in offering the appropriate refractive index gradient, intermolecular short range attractive interactions (aiding in packing them into a transparent ball), the role that several of the constituent amino acid residues play in this process, the thermodynamic and kinetic stability and how even single point mutations can upset this delicate balance and lead to intermolecular aggregation, forming light-scattering particles which compromise transparency. We cite several examples of this, and illustrate this by cloning, expressing, isolating and comparing the properties of the mutant protein S39C of human γS-crystallin (associated with congenital cataract-microcornea), with those of the wild type molecule. In addition, we note that human γ-crystallins are also present in other parts of the eye (e.g., retina), where their functions are yet to be understood. There are several 'crucial' residues in and around the Greek key motifs which are essential to maintain the compact architecture of the crystallin molecules. We find that a mutation that replaces even one of these residues can lead to reduction in solubility, formation of light-scattering particles and loss of transparency in the molecular assembly. Such a molecular understanding of the process helps us construct the

  1. Effects of Antifungal Soaked Silicone Hydrogel Contact Lenses on Candida albicans in an Agar Eye Model.

    Science.gov (United States)

    Phan, Chau-Minh; Bajgrowicz, Magdalena; McCanna, David J; Subbaraman, Lakshman N; Jones, Lyndon

    2016-09-01

    To evaluate the effects of two commercial silicone hydrogel contact lenses (CLs) soaked with natamycin (NA) or fluconazole (FL) on the growth of Candida albicans in an in vitro eye model. Three-D printed molds were used as a cast for making eye-shaped models comprising potato dextrose agar. Senofilcon A (SA) and lotrafilcon B (LB) CLs were incubated with either 2 mL of NA or FL at a concentration of 1 mg/mL for 24 hr. To simulate a fungal infection, the eye models were coated with C. albicans. The drug-soaked lenses were placed on top of the eye models. Seven experimental conditions were examined: (1) NA-SA, (2) NA-LB, (3) FL-SA, (4) FL-LB, (5) SA, (6) LB, and (7) control-no lens. At specified time points (t=1, 8, 16, 24, 48 hr), the agar eyes from each experimental condition were removed from the incubator and photographed. The yeast cells from the 24 and 48 hr time point were also analyzed using light microscopy. At 24 and 48 hr, there was considerable growth observed for all conditions except for the NA-SA and NA-LB conditions. When observed under the microscope at 24 and 48 hr, the morphology of the yeast cells in the FL-SA and SA condition were similar to that of the control (oval shaped). There was limited hyphae growth observed for LB and significant visible hyphae growth for the NA-LB group. For NA-SA, NA-LB, and FL-LB groups, the cells were significantly smaller compared with the control. For NA-SA and NA-LB, there was limited growth of C. albicans observed on the eye models even after 48 hr. Under the microscope, the cell morphology differ noticeably between each testing condition, and is dependent on drug-lens combinations.

  2. METHOD OF NON-CONTACT PHOTOLUMINESCENT DIAGNOSTICS OF THE EYE FIBROUS TUNIC CONDITION

    Directory of Open Access Journals (Sweden)

    S. Yu. Petrov

    2018-01-01

    Full Text Available Non-contact optical diagnostics of structural disorders of the eye has a number of advantages: high speed, accuracy and a large range of parameters available for analysis. The paper presents the results of studies of the photoluminescence of the fibrous tunic of the eye, excited by polarized light, depending on the intraocular pressure. In the experiments, isolated de-epithelized eyes of the rabbit were used, inside of which pressure up to 50 mm Hg was artificially created. Under these conditions, the cornea and sclera were illuminated with linearly polarized light at wavelengths of 250, 350 and 450 nm, exciting photoluminescence in the wavelength range up to 700 nm. Cross and co-polarized photoluminescence spectra excited by linearly polarized light were obtained. It has been established that, when excited by polarized light, the photoluminescence of the cornea is partially polarized. Depending on the wavelength of the photoluminescence, the degree of polarization varies from 0.2 to 0.35. It is shown that the degree of polarization of the photoluminescence of the cornea of the eye upon excitation by linearly polarized light can be used as a measurable parameter for assessing the physiological state of the eye. It is shown that the photoluminescence spectrum consists of two bands with maxima near 460-470 and 430-440 nm. These bands are assigned, respectively, to pyridinnucleotides and glycosylated collagen. A significant contribution can be made by the epithelium of the eye, which contains riboflavin with characteristic absorption bands near 450 and 365 nm. When excited at 450 nm, the photoluminescence maximum is located near 540 nm, which corresponds to the spectrum of fluorophores in the endothelium and epithelium. The spectrum of photoluminescence upon excitation at a wavelength of 250 nm can be attributed to tryptophan located in the intraocular lens.

  3. A novel algorithm for automatic localization of human eyes

    Institute of Scientific and Technical Information of China (English)

    Liang Tao (陶亮); Juanjuan Gu (顾涓涓); Zhenquan Zhuang (庄镇泉)

    2003-01-01

    Based on geometrical facial features and image segmentation, we present a novel algorithm for automatic localization of human eyes in grayscale or color still images with complex background. Firstly, a determination criterion of eye location is established by the prior knowledge of geometrical facial features. Secondly,a range of threshold values that would separate eye blocks from others in a segmented face image (I.e.,a binary image) are estimated. Thirdly, with the progressive increase of the threshold by an appropriate step in that range, once two eye blocks appear from the segmented image, they will be detected by the determination criterion of eye location. Finally, the 2D correlation coefficient is used as a symmetry similarity measure to check the factuality of the two detected eyes. To avoid the background interference, skin color segmentation can be applied in order to enhance the accuracy of eye detection. The experimental results demonstrate the high efficiency of the algorithm and correct localization rate.

  4. Acanthamoeba keratitis in a non-contact lens wearer with human immunodeficiency virus

    DEFF Research Database (Denmark)

    Hansen, Birgitte Rønde; Kronborg, Gitte

    2003-01-01

    , and was treated with various topical antibiotics and steroids. 13 months after symptom onset the eye was removed owing to serious scarring of cornea and unbearable pain. Microbiological and histopathological examination of the cornea showed Acanthamoeba. In non-contact lens wearers suffering from Acanthamoeba......Acanthamoeba keratitis is potentially blinding and often associated with contact lens wearing. A human immunodeficiency virus (HIV)-positive patient, a non-contact lens wearer, presented with keratitis. She experienced a protracted course of disease, characterized by exacerbations and remissions...

  5. Evaluation of refractive correction for standard automated perimetry in eyes wearing multifocal contact lenses.

    Science.gov (United States)

    Hirasawa, Kazunori; Ito, Hikaru; Ohori, Yukari; Takano, Yui; Shoji, Nobuyuki

    2017-01-01

    To evaluate the refractive correction for standard automated perimetry (SAP) in eyes with refractive multifocal contact lenses (CL) in healthy young participants. Twenty-nine eyes of 29 participants were included. Accommodation was paralyzed in all participants with 1% cyclopentolate hydrochloride. SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions: monofocal CL corrected for near distance (baseline); multifocal CL corrected for distance (mCL-D); and mCL-D corrected for near vision using a spectacle lens (mCL-N). Primary outcome measures were the foveal threshold, mean deviation (MD), and pattern standard deviation (PSD). The foveal threshold of mCL-N with both the 24-2 and 10-2 protocols significantly decreased by 2.2-2.5 dB ( P correction without additional near correction is to be recommended.

  6. Indentation and needle insertion properties of the human eye.

    Science.gov (United States)

    Matthews, A; Hutnik, C; Hill, K; Newson, T; Chan, T; Campbell, G

    2014-07-01

    Characterization of the biomechanical properties of the human eye has a number of potential utilities. One novel purpose is to provide the basis for development of suitable tissue-mimicking material. The purpose of this study was to determine the indentation and needle insertion characteristics on human eye globes and tissue strips. An indenter assessed the elastic response of human eye globes and tissue strips under increasing compressive loads. Needle insertion determined the force (N) needed to penetrate various areas of the eye wall. The results demonstrated that globes underwent slightly greater indentation at the midline than at the central cornea, and corneal strips indented twofold more than scleral strips, although neither difference was significant (P=0.400 and P=0.100, respectively). Significant differences were observed among various areas of needle insertion (Phuman eye construct with potential utility as a model for use in ophthalmology research and surgical teaching.

  7. Human eye and the sun hot and cold light

    CERN Document Server

    Vavilov, S I

    1965-01-01

    The Human Eye and the Sun, """"Hot"""" and """"Cold"""" Light is a translation from the Russian language and is a reproduction of texts from Volume IV of S.I. Vavilov, president of the U.S.S.R. Academy of Sciences. The book deals with theoretical and practical developments in lighting techniques. The text gives a brief introduction on the relationship of the human eye and the sun, describing the properties of light, of the sun, and of the human eye. The book describes hot (incandescence) and cold light (luminescence) as coming from different sources. These two types of light are compared. The

  8. Human eye localization using the modified Hough transform

    Czech Academy of Sciences Publication Activity Database

    Dobeš, M.; Martínek, J.; Skoupil, D.; Dobešová, Z.; Pospíšil, Jaroslav

    2006-01-01

    Roč. 117, - (2006), s. 468-473 ISSN 0030-4026 Institutional research plan: CEZ:AV0Z10100522 Keywords : human eye localization * modified Hough transform * eye iris and eyelid shape determination Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.585, year: 2006

  9. Relating Eye Activity Measures to Human Controller Remnant Characteristics

    NARCIS (Netherlands)

    Popovici, A; Zaal, P.M.T.; Pool, D.M.; Mulder, M.; Sawaragi, T

    2016-01-01

    This study attempts to partially explain the characteristics of the human perceptual remnant, following Levison’s representation of the remnant as an equivalent observation noise. Eye activity parameters are recorded using an eye tracker in two compensatory tracking tasks in which the visual

  10. Human eye colour and HERC2, OCA2 and MATP

    DEFF Research Database (Denmark)

    Mengel-From, Jonas; Børsting, Claus; Sanchez, Juan J

    2010-01-01

    Prediction of human eye colour by forensic genetic methods is of great value in certain crime investigations. Strong associations between blue/brown eye colour and the SNP loci rs1129038 and rs12913832 in the HERC2 gene were recently described. Weaker associations between eye colour and other...... genetic markers also exist. In 395 randomly selected Danes, we investigated the predictive values of various combinations of SNP alleles in the HERC2, OCA2 and MATP (SLC45A2) genes and compared the results to the eye colours as they were described by the individuals themselves. The highest predictive...

  11. Stress free configuration of the human eye.

    Science.gov (United States)

    Elsheikh, Ahmed; Whitford, Charles; Hamarashid, Rosti; Kassem, Wael; Joda, Akram; Büchler, Philippe

    2013-02-01

    Numerical simulations of eye globes often rely on topographies that have been measured in vivo using devices such as the Pentacam or OCT. The topographies, which represent the form of the already stressed eye under the existing intraocular pressure, introduce approximations in the analysis. The accuracy of the simulations could be improved if either the stress state of the eye under the effect of intraocular pressure is determined, or the stress-free form of the eye estimated prior to conducting the analysis. This study reviews earlier attempts to address this problem and assesses the performance of an iterative technique proposed by Pandolfi and Holzapfel [1], which is both simple to implement and promises high accuracy in estimating the eye's stress-free form. A parametric study has been conducted and demonstrated reliance of the error level on the level of flexibility of the eye model, especially in the cornea region. However, in all cases considered 3-4 analysis iterations were sufficient to produce a stress-free form with average errors in node location <10(-6)mm and a maximal error <10(-4)mm. This error level, which is similar to what has been achieved with other methods and orders of magnitude lower than the accuracy of current clinical topography systems, justifies the use of the technique as a pre-processing step in ocular numerical simulations. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  12. Evaluation of refractive correction for standard automated perimetry in eyes wearing multifocal contact lenses

    Directory of Open Access Journals (Sweden)

    Kazunori Hirasawa

    2017-10-01

    Full Text Available AIM: To evaluate the refractive correction for standard automated perimetry (SAP in eyes with refractive multifocal contact lenses (CL in healthy young participants. METHODS: Twenty-nine eyes of 29 participants were included. Accommodation was paralyzed in all participants with 1% cyclopentolate hydrochloride. SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions: monofocal CL corrected for near distance (baseline; multifocal CL corrected for distance (mCL-D; and mCL-D corrected for near vision using a spectacle lens (mCL-N. Primary outcome measures were the foveal threshold, mean deviation (MD, and pattern standard deviation (PSD. RESULTS: The foveal threshold of mCL-N with both the 24-2 and 10-2 protocols significantly decreased by 2.2-2.5 dB CONCLUSION: Despite the induced mydriasis and the optical design of the multifocal lens used in this study, our results indicated that, when the dome-shaped visual field test is performed with eyes with large pupils and wearing refractive multifocal CLs, distance correction without additional near correction is to be recommended.

  13. The Use of the Esclera Scleral Contact Lens in the Treatment of Moderate to Severe Dry Eye Disease.

    Science.gov (United States)

    La Porta Weber, Sarah; Becco de Souza, Rodrigo; Gomes, José Álvaro Pereira; Hofling-Lima, Ana Luisa

    2016-03-01

    To evaluate the efficacy of the Esclera scleral contact lens (SCL) treatment and its impact on clinical testing for moderate to severe dry eye disease (DED). Prospective interventional case series. A total of 41 eyes from 25 patients with moderate to severe DED were evaluated for the Esclera SCL treatment. Best-corrected visual acuity (BCVA), tear osmolarity, the Schirmer I test, tear film breakup time (TBUT), corneal and conjunctival staining, meibomian grading, and Ocular Surface Disease Index and SF-36v2 questionnaires were assessed before and after the SCL treatment. These values were compared to assess the real benefit of using SCL as a treatment for DED. Forty-one eyes from 25 patients were fitted with SCL for management of DED. The underlying diseases were Stevens-Johnson syndrome (22 eyes), Sjogren syndrome (11 eyes), graft-vs-host disease (2 eyes), dry eye after keratomileusis in situ (2 eyes), and undifferentiated ocular surface disease (4 eyes). BCVA improved from 0.703 ± 0.55 logMAR with habitual correction to 0.406 ± 0.43 logMAR with SCL (P dry eye symptoms and quality of life as assessed by the OSDI and SF-36v2 questionnaires (both with P dry eye symptoms, and quality of life. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Simulation of wave propagation inside a human eye: acoustic eye model (AEM)

    Science.gov (United States)

    Požar, T.; Halilovič, M.; Horvat, D.; Petkovšek, R.

    2018-02-01

    The design and development of the acoustic eye model (AEM) is reported. The model consists of a computer-based simulation that describes the propagation of mechanical disturbance inside a simplified model of a human eye. The capabilities of the model are illustrated with examples, using different laser-induced initial loading conditions in different geometrical configurations typically occurring in ophthalmic medical procedures. The potential of the AEM is to predict the mechanical response of the treated eye tissue in advance, thus complementing other preliminary procedures preceding medical treatments.

  15. Social Attention in the Two Species of Pan: Bonobos Make More Eye Contact than Chimpanzees.

    Directory of Open Access Journals (Sweden)

    Fumihiro Kano

    Full Text Available Humans' two closest primate living relatives, bonobos and chimpanzees, differ behaviorally, cognitively, and emotionally in several ways despite their general similarities. While bonobos show more affiliative behaviors towards conspecifics, chimpanzees display more overt and severe aggression against conspecifics. From a cognitive standpoint, bonobos perform better in social coordination, gaze-following and food-related cooperation, while chimpanzees excel in tasks requiring extractive foraging skills. We hypothesized that attention and motivation play an important role in shaping the species differences in behavior, cognition, and emotion. Thus, we predicted that bonobos would pay more attention to the other individuals' face and eyes, as those are related to social affiliation and social coordination, while chimpanzees would pay more attention to the action target objects, as they are related to foraging. Using eye-tracking we examined the bonobos' and chimpanzees' spontaneous scanning of pictures that included eyes, mouth, face, genitals, and action target objects of conspecifics. Although bonobos and chimpanzees viewed those elements overall similarly, bonobos viewed the face and eyes longer than chimpanzees, whereas chimpanzees viewed the other elements, the mouth, action target objects and genitals, longer than bonobos. In a discriminant analysis, the individual variation in viewing patterns robustly predicted the species of individuals, thus clearly demonstrating species-specific viewing patterns. We suggest that such attentional and motivational differences between bonobos and chimpanzees could have partly contributed to shaping the species-specific behaviors, cognition, and emotion of these species, even in a relatively short period of evolutionary time.

  16. Human eye analytical and mesh-geometry models for ophthalmic dosimetry using MCNP6

    International Nuclear Information System (INIS)

    Angelocci, Lucas V.; Fonseca, Gabriel P.; Yoriyaz, Helio

    2015-01-01

    Eye tumors can be treated with brachytherapy using Co-60 plaques, I-125 seeds, among others materials. The human eye has regions particularly vulnerable to ionizing radiation (e.g. crystalline) and dosimetry for this region must be taken carefully. A mathematical model was proposed in the past [1] for the eye anatomy to be used in Monte Carlo simulations to account for dose distribution in ophthalmic brachytherapy. The model includes the description for internal structures of the eye that were not treated in previous works. The aim of this present work was to develop a new eye model based on the Mesh geometries of the MCNP6 code. The methodology utilized the ABAQUS/CAE (Simulia 3DS) software to build the Mesh geometry. For this work, an ophthalmic applicator containing up to 24 model Amersham 6711 I-125 seeds (Oncoseed) was used, positioned in contact with a generic tumor defined analytically inside the eye. The absorbed dose in eye structures like cornea, sclera, choroid, retina, vitreous body, lens, optical nerve and optical nerve wall were calculated using both models: analytical and MESH. (author)

  17. Human eye analytical and mesh-geometry models for ophthalmic dosimetry using MCNP6

    Energy Technology Data Exchange (ETDEWEB)

    Angelocci, Lucas V.; Fonseca, Gabriel P.; Yoriyaz, Helio, E-mail: hyoriyaz@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Eye tumors can be treated with brachytherapy using Co-60 plaques, I-125 seeds, among others materials. The human eye has regions particularly vulnerable to ionizing radiation (e.g. crystalline) and dosimetry for this region must be taken carefully. A mathematical model was proposed in the past [1] for the eye anatomy to be used in Monte Carlo simulations to account for dose distribution in ophthalmic brachytherapy. The model includes the description for internal structures of the eye that were not treated in previous works. The aim of this present work was to develop a new eye model based on the Mesh geometries of the MCNP6 code. The methodology utilized the ABAQUS/CAE (Simulia 3DS) software to build the Mesh geometry. For this work, an ophthalmic applicator containing up to 24 model Amersham 6711 I-125 seeds (Oncoseed) was used, positioned in contact with a generic tumor defined analytically inside the eye. The absorbed dose in eye structures like cornea, sclera, choroid, retina, vitreous body, lens, optical nerve and optical nerve wall were calculated using both models: analytical and MESH. (author)

  18. Human eye colour and HERC2, OCA2 and MATP

    DEFF Research Database (Denmark)

    Mengel-From, Jonas; Børsting, Claus; Sanchez, Juan J.

    2010-01-01

    Prediction of human eye colour by forensic genetic methods is of great value in certain crime investigations. Strong associations between blue/brown eye colour and the SNP loci rs1129038 and rs12913832 in the HERC2 gene were recently described. Weaker associations between eye colour and other...... value of typing either the HERC2 SNPs rs1129038 and/or rs12913832 that are in strong linkage disequilibrium was observed when eye colour was divided into two groups, (1) blue, grey and green (light) and (2) brown and hazel (dark). Sequence variations in rs11636232 and rs7170852 in HERC2, rs1800407...... genetic markers also exist. In 395 randomly selected Danes, we investigated the predictive values of various combinations of SNP alleles in the HERC2, OCA2 and MATP (SLC45A2) genes and compared the results to the eye colours as they were described by the individuals themselves. The highest predictive...

  19. Optimized Two-Party Video Chat with Restored Eye Contact Using Graphics Hardware

    Science.gov (United States)

    Dumont, Maarten; Rogmans, Sammy; Maesen, Steven; Bekaert, Philippe

    We present a practical system prototype to convincingly restore eye contact between two video chat participants, with a minimal amount of constraints. The proposed six-fold camera setup is easily integrated into the monitor frame, and is used to interpolate an image as if its virtual camera captured the image through a transparent screen. The peer user has a large freedom of movement, resulting in system specifications that enable genuine practical usage. Our software framework thereby harnesses the powerful computational resources inside graphics hardware, and maximizes arithmetic intensity to achieve over real-time performance up to 42 frames per second for 800 ×600 resolution images. Furthermore, an optimal set of fine tuned parameters are presented, that optimizes the end-to-end performance of the application to achieve high subjective visual quality, and still allows for further algorithmic advancement without loosing its real-time capabilities.

  20. Investigation of biofilm formation on contact eye lenses caused by methicillin resistant Staphylococcus aureus.

    Science.gov (United States)

    Khalil, M A; Sonbol, F I

    2014-01-01

    The objective was to investigate the biofilm-forming capacity of methicillin resistant Staphylococcus aureus (MRSA) isolated from eye lenses of infected patients. A total of 32 MRSA isolated from contact lenses of patients with ocular infections were screened for their biofilm-forming capacity using tube method (TM), Congo red agar (CRA), and microtiter plate (MtP) methods. The effect of some stress factor on the biofilm formation was studied. The biofilm-forming related genes, icaA, icaD and 10 microbial surface components that recognize adhesive matrix molecule (MSCRAMM), of the selected MRSA were also detected using polymerase chain reaction. Of 32 MRSA isolates, 34.37%, 59.37%, and 81.25% showed positive results using CRA, TM or MtP, respectively. Biofilm production was found to be reduced in the presence of ethanol or ethylenediaminetetraacetic acid and at extreme pH values. On the other hand, glucose or heparin leads to a concentration dependent increase of biofilm production by the isolates. The selected biofilm producing MRSA isolate was found to harbor the icaA, icaD and up to nine of 10 tested MSCRAMM genes, whereas the selected non biofilm producing MRSA isolate did not carry any of the tested genes. The MtP method was found to be the most effective phenotypic screening method for detection of biofilm formation by MRSA. Furthermore, the molecular approach should be taken into consideration for the rapid and correct diagnosis of virulent bacteria associated with contact eye lenses.

  1. Eye contact with neutral and smiling faces: effects on frontal EEG asymmetry and autonomic responses

    Directory of Open Access Journals (Sweden)

    Laura Maria Pönkänen

    2012-05-01

    Full Text Available In our previous studies we have shown that seeing another person live with a direct vs. averted gaze results in greater relative left-sided frontal asymmetry in the electroencephalography (EEG, associated with approach motivation, and in enhanced skin conductance responses indicating autonomic arousal. In our studies, however, the stimulus persons had a neutral expression. In real-life social interaction, eye contact is often associated with a smile, which is another signal of the sender’s approach-related motivation. A smile could therefore enhance the affective-motivational responses to eye contact. In the present study, we investigated whether the facial expression (neutral vs. smile would modulate the frontal EEG asymmetry and autonomic arousal to seeing a direct vs. an averted gaze in faces presented live through a liquid crystal shutter. The results showed that the skin conductance responses were greater for the direct than the averted gaze and that the effect of gaze direction was more pronounced for a smiling than a neutral face. However, the frontal EEG asymmetry results revealed a more complex pattern. Participants whose responses to seeing the other person were overall indicative of leftward frontal activity (indicative of approach showed greater relative left-sided asymmetry for the direct vs. averted gaze, whereas participants whose responses were overall indicative of rightward frontal activity (indicative of avoidance showed greater relative right-sided asymmetry to direct vs. averted gaze. The other person’s facial expression did not have an effect on the frontal EEG asymmetry. These findings may reflect that another’s direct gaze, as compared to their smile, has a more dominant role in regulating perceivers’ approach motivation.

  2. Neural activity in the posterior superior temporal region during eye contact perception correlates with autistic traits.

    Science.gov (United States)

    Hasegawa, Naoya; Kitamura, Hideaki; Murakami, Hiroatsu; Kameyama, Shigeki; Sasagawa, Mutsuo; Egawa, Jun; Endo, Taro; Someya, Toshiyuki

    2013-08-09

    The present study investigated the relationship between neural activity associated with gaze processing and autistic traits in typically developed subjects using magnetoencephalography. Autistic traits in 24 typically developed college students with normal intelligence were assessed using the Autism Spectrum Quotient (AQ). The Minimum Current Estimates method was applied to estimate the cortical sources of magnetic responses to gaze stimuli. These stimuli consisted of apparent motion of the eyes, displaying direct or averted gaze motion. Results revealed gaze-related brain activations in the 150-250 ms time window in the right posterior superior temporal sulcus (pSTS), and in the 150-450 ms time window in medial prefrontal regions. In addition, the mean amplitude in the 150-250 ms time window in the right pSTS region was modulated by gaze direction, and its activity in response to direct gaze stimuli correlated with AQ score. pSTS activation in response to direct gaze is thought to be related to higher-order social processes. Thus, these results suggest that brain activity linking eye contact and social signals is associated with autistic traits in a typical population. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  3. Basement membrane abnormalities in human eyes with diabetic retinopathy

    DEFF Research Database (Denmark)

    Ljubimov, A V; Burgeson, R E; Butkowski, R J

    1996-01-01

    Vascular and parenchymal basement membranes (BMs) are thickened in diabetes, but alterations in individual BM components in diabetic eyes, especially in diabetic retinopathy (DR), are obscure. To identify abnormalities in the distribution of specific constituents, we analyzed cryostat sections...... of human eyes obtained at autopsy (seven normal, five diabetic without DR, and 13 diabetic with DR) by immunofluorescence with antibodies to 30 BM and extracellular matrix components. In non-DR eyes, no qualitative changes of ocular BM components were seen. In some DR corneas, epithelial BM was stained...... discontinuously for laminin-1, entactin/nidogen, and alpha3-alpha4 Type IV collagen, in contrast to non-DR corneas. Major BM alterations were found in DR retinas compared to normals and non-DR diabetics. The inner limiting membrane (retinal BM) of DR eyes had accumulations of fibronectin (including cellular...

  4. Controlled delivery of antiangiogenic drug to human eye tissue using a MEMS device

    KAUST Repository

    Pirmoradi, Fatemeh Nazly

    2013-01-01

    We demonstrate an implantable MEMS drug delivery device to conduct controlled and on-demand, ex vivo drug transport to human eye tissue. Remotely operated drug delivery to human post-mortem eyes was performed via a MEMS device. The developed curved packaging cover conforms to the eyeball thereby preventing the eye tissue from contacting the actuating membrane. By pulsed operation of the device, using an externally applied magnetic field, the drug released from the device accumulates in a cavity adjacent to the tissue. As such, docetaxel (DTX), an antiangiogenic drug, diffuses through the eye tissue, from sclera and choroid to retina. DTX uptake by sclera and choroid were measured to be 1.93±0.66 and 7.24±0.37 μg/g tissue, respectively, after two hours in pulsed operation mode (10s on/off cycles) at 23°C. During this period, a total amount of 192 ng DTX diffused into the exposed tissue. This MEMS device shows great potential for the treatment of ocular posterior segment diseases such as diabetic retinopathy by introducing a novel way of drug administration to the eye. © 2013 IEEE.

  5. Effect of aberrations in human eye on contrast sensitivity function

    Science.gov (United States)

    Quan, Wei; Wang, Feng-lin; Wang, Zhao-qi

    2011-06-01

    The quantitative analysis of the effect of aberrations in human eye on vision has important clinical value in the correction of aberrations. The wave-front aberrations of human eyes were measured with the Hartmann-Shack wave-front sensor and modulation transfer function (MTF) was computed from the wave-front aberrations. Contrast sensitivity function (CSF) was obtained from MTF and the retinal aerial image modulation (AIM). It is shown that the 2nd, 3rd, 4th, 5th, 6th Zernike aberrations deteriorate contrast sensitivity function. When the 2nd, 3rd, 4th, 5th, 6th Zernike aberrations are corrected high contrast sensitivity function can be obtained.

  6. Molecular Diagnosis of Human Taenia martis Eye Infection.

    Science.gov (United States)

    Koch, Till; Schoen, Christoph; Muntau, Birgit; Addo, Marylyn; Ostertag, Helmut; Wiechens, Burkhard; Tappe, Dennis

    2016-05-04

    Taenia martis, a tapeworm harbored in the intestine of mustelids, is a rarely encountered zoonotic cysticercosis pathogen. The larval stage closely resembles the Taenia solium cysticercus, but the natural host and thus the epidemiology of the disease is different. We here report a human eye infection diagnosed molecularly in a previously healthy female German patient. The case represents the third human infection described worldwide; the two previous cases were also European, involving eye and brain. © The American Society of Tropical Medicine and Hygiene.

  7. Immunologic contact urticaria--the human touch.

    Science.gov (United States)

    Wang, Christina Y; Maibach, Howard I

    2013-06-01

    To review immunologic contact urticaria (ICU) in the occupational and environmental context, and describe its continued relevance in light of the ever-increasing onslaught of new chemicals and products, as well as new technology placing novel interactions, such as nanoparticles, within reach of the population at home and work. Publications were searched via PubMed, using key words: Occupational, immunologic, contact urticaria, nanoparticle. ICU remains an important diagnosis to make and treat because it has widespread health and social morbidity, including job and income loss, persistent life-long allergies, and progression from self-limiting skin eruptions to multi-systemic, sometimes life-threatening, illnesses. There is no short supply of known ICU causing allergens, but it is equally important to be ever vigilant in recognizing, and even adding to, items in the constantly expanding list of novel allergenic agents provided to us by the advances of modern chemistry and technology, and by the changing social structure and lifestyle dynamics.

  8. Reliability of the non-contact tono-pachymeter Tonopachy NT-530P in healthy eyes.

    Science.gov (United States)

    García-Resúa, Carlos; Pena-Verdeal, Hugo; Miñones, Mercedes; Giraldez, M Jesus; Yebra-Pimentel, Eva

    2013-05-01

    Non-contact Tonopachy NT-530P (Nidek Co., LTD) provides intraocular pressure (IOP) and central corneal thickness (CCT) measurements. This study assesses the reliability and repeatability of its IOP measurements in young healthy adult subjects. IOP was determined in the right eye of 64 healthy patients using Tonopachy followed by the Canon TX-10 non-contact and Goldmann applanation (GAT) tonometers. Tonopachy IOP measurements were corrected (Tonopachy-C) or not (Tonopachy-NC) by the instrument for central corneal thickness. Central corneal thickness measurements provided by Tonopachy were also used to correlate (Pearson's coefficient) central corneal thickness with the GAT and Canon TX-10 IOPs. Repeatability of Tonopachy and GAT was assessed in the right eye of 31 subjects in two separate sessions one week apart. Differences between pairs of instruments and between sessions were determined using Bland-Altman plots. The coefficient of repeatability was calculated as the 95% limits of agreement (LoA) of differences between the two sessions. Tonopachy-NC, Tonopachy-C, Canon TX-10 and the Goldmann tonometers showed a mean IOP of 14.62, 15.64, 15.02 and 14.68 mmHg, respectively. Tonopachy-NC and Canon TX-10 readings did not differ significantly from the Goldmann (p > 0.05), with close agreement with both tonometers (GAT versus Tonopachy-NC: -3.84 to 3.96 mmHg; Goldmann versus Canon TX-10: -4.75 to 4.07 mmHg). Tonopachy-C readings differed significantly from Goldmann (mean difference -0.96 mmHg, p = 0.001, LoA from -5.09 to 3.17). Coefficients of repeatability were ± 3.70, ± 3.14 and ± 3.33 mmHg for GAT, Tonopachy-NC and Tonopachy-C, respectively. Central corneal thickness measured with Tonopachy was 530.42 ± 34.96 μm. There was a significant correlation between central corneal thickness and IOP for all tonometers except Tonopachy-C. Reasonable agreement was observed between the Goldmann and Tonopachy. This instrument provides reliable and repeatable IOP

  9. Measuring contact area in a sliding human finger-pad contact.

    Science.gov (United States)

    Liu, X; Carré, M J; Zhang, Q; Lu, Z; Matcher, S J; Lewis, R

    2018-02-01

    The work outlined in this paper was aimed at achieving further understanding of skin frictional behaviour by investigating the contact area between human finger-pads and flat surfaces. Both the static and the dynamic contact areas (in macro- and micro-scales) were measured using various techniques, including ink printing, optical coherence tomography (OCT) and Digital Image Correlation (DIC). In the studies of the static measurements using ink printing, the experimental results showed that the apparent and the real contact area increased with load following a piecewise linear correlation function for a finger-pad in contact with paper sheets. Comparisons indicated that the OCT method is a reliable and effective method to investigate the real contact area of a finger-pad and allow micro-scale analysis. The apparent contact area (from the DIC measurements) was found to reduce with time in the transition from the static phase to the dynamic phase while the real area of contact (from OCT) increased. The results from this study enable the interaction between finger-pads and contact object surface to be better analysed, and hence improve the understanding of skin friction. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Contact fatigue of human enamel: Experiments, mechanisms and modeling.

    Science.gov (United States)

    Gao, S S; An, B B; Yahyazadehfar, M; Zhang, D; Arola, D D

    2016-07-01

    Cyclic contact between natural tooth structure and engineered ceramics is increasingly common. Fatigue of the enamel due to cyclic contact is rarely considered. The objectives of this investigation were to evaluate the fatigue behavior of human enamel by cyclic contact, and to assess the extent of damage over clinically relevant conditions. Cyclic contact experiments were conducted using the crowns of caries-free molars obtained from young donors. The cuspal locations were polished flat and subjected to cyclic contact with a spherical indenter of alumina at 2Hz. The progression of damage was monitored through the evolution in contact displacement, changes in the contact hysteresis and characteristics of the fracture pattern. The contact fatigue life diagram exhibited a decrease in cycles to failure with increasing cyclic load magnitude. Two distinct trends were identified, which corresponded to the development and propagation of a combination of cylindrical and radial cracks. Under contact loads of less than 400N, enamel rod decussation resisted the growth of subsurface cracks. However, at greater loads the damage progressed rapidly and accelerated fatigue failure. Overall, cyclic contact between ceramic appliances and natural tooth structure causes fatigue of the enamel. The extent of damage is dependent on the magnitude of cyclic stress and the ability of the decussation to arrest the fatigue damage. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Human volunteer study with PGME: Eye irritation during vapour exposure

    NARCIS (Netherlands)

    Emmen, H.H.; Muijser, H.; Arts, J.H.E.; Prinsen, M.K.

    2003-01-01

    The objective of this study was to establish the possible occurrence of eye irritation and subjective symptoms in human volunteers exposed to propylene glycol monomethyl ether (PGME) vapour at concentrations of 0, 100 and 150 ppm. Testing was conducted in 12 healthy male volunteers using a repeated

  12. Human rights: eye for cultural diversity

    NARCIS (Netherlands)

    Donders, Y.M.

    2012-01-01

    The relationship and interaction between international human rights law and cultural diversity is a current topic, as is shown by the recent debates in The Netherlands on, for instance, the proposed ban on wearing facial coverage, or burqas, and the proposed ban on ritual slaughter without

  13. Prediction of human eye fixations using symmetry

    NARCIS (Netherlands)

    Kootstra, Gert; Schomaker, Lambert

    2009-01-01

    Humans are very sensitive to symmetry in visual patterns. Reaction time experiments show that symmetry is detected and recognized very rapidly. This suggests that symmetry is a highly salient feature. Existing computational models of saliency, however, have mainly focused on contrast as a measure of

  14. Acanthamoeba keratitis in a non-contact lens wearer with human immunodeficiency virus

    DEFF Research Database (Denmark)

    Hansen, Birgitte Rønde; Kronborg, Gitte

    2003-01-01

    Acanthamoeba keratitis is potentially blinding and often associated with contact lens wearing. A human immunodeficiency virus (HIV)-positive patient, a non-contact lens wearer, presented with keratitis. She experienced a protracted course of disease, characterized by exacerbations and remissions......, and was treated with various topical antibiotics and steroids. 13 months after symptom onset the eye was removed owing to serious scarring of cornea and unbearable pain. Microbiological and histopathological examination of the cornea showed Acanthamoeba. In non-contact lens wearers suffering from Acanthamoeba...... keratitis the diagnosis is delayed, pathognomonic features are often not seen and visual outcome is usually poor. There is no known relation between HIV infection and Acanthamoeba keratitis....

  15. Design of an in-vivo microscope to characterize cataracts in human eyes

    Science.gov (United States)

    Feng, Chen; Ahmad, Anees

    1996-11-01

    The design of a compact contact microscope, which can be used in-vivo to study the cataracts in human eyes is presented. This microscope has the capability to evaluate the changes in the optical density within the eye lens itself, and thus enabling an examiner to ascertain the progression of a cataractous change or at least the optical changes associated with cataractous development. The microscope has a variable focal length so it can be focused at any depth through the entire thickness of the eye lens. A separate small objective lens is spring loaded against the cornea (like a tonometer tip) so that the natural eye movements can occur safely during the examination. The distance between the objective lens and rest of the optics is variable to accommodate the movements of the eye due to pulse or breathing without affecting the image quality of the instrument. The layer by layer images can be captured on a CCD camera and stored in the computer. The reconstruction software can quantitatively display the characteristics of the cataracts, such as the location, size, and density. The optical design and performance results for the microscope are presented. The optomechanical design features of the microscope are also discussed.

  16. Analysis of toxic and heavy metals in cataract extraction from human eyes

    International Nuclear Information System (INIS)

    Tanvir, R.; Qureshi, S.A.; Ahmed, R.

    1999-01-01

    Surma and many other substances are frequently used for the treatment of eyes and for cosmetic purposes, which may contain large quantities of toxic and heavy metals particularly lead. Toxic metals may also enter into the body through different food chain system and also due to heavy traffic and contaminated dusts in the air of the overcrowded cities. Eyes being exposed part of human body has maximum chances to get in contact with polluted atmosphere. This study has been undertaken to find the role of toxic elements in the formation of cataract in eyes. Samples of eye lenses were collected and carefully digested in 3 ml of conc. HClO/sub 4/ and 1 ml of conc. HNO/sub 3/. Then analysis of Zn, Cd, Pb, Cu, was carried out in 0.02 m HClO/sub 4/ using differential pulse anodic stripping voltametry. Levels of Zn, Cd, Pb and Cu in eye lenses are from 324 - 5746 mug/g, 3 - 240 mug/g, 3 - 240 mug/g, 25 - 120 mug /g and 23 - 485 mug/g, respectively. Chemical composition of ocular fluid indicates that Pb, Cd, Cu, Zn are not present in it normally. In addition to other factors , role of heavy and toxic metals in the formation of cataract cannot be overlooked. Therefore, use of surma and other cosmetics should be discouraged. (author)

  17. Measuring the human psychophysiological conditions without contact

    Science.gov (United States)

    Scalise, L.; Casacanditella, L.; Cosoli, G.

    2017-08-01

    Heart Rate Variability, HRV, studies the variations of cardiac rhythm caused by the autonomic regulation. HRV analysis can be applied to the study of the effects of mental or physical stressors on the psychophysiological conditions. The present work is a pilot study performed on a 23-year-old healthy subject. The measurement of HRV was performed by means of two sensors, that is an electrocardiograph and a Laser Doppler Vibrometer, which is a non-contact device able to detect the skin vibrations related to the cardiac activity. The present study aims to evaluate the effects of a physical task on HRV parameters (in both time and frequency domain), and consequently on the autonomic regulation, and the capability of Laser Doppler Vibrometry in correctly detecting the effects of stress on the Heart Variability. The results show a significant reduction of HRV parameters caused by the execution of the physical task (i.e. variations of 25-40% for parameters in time domain, also higher in frequency domain); this is consistent with the fact that stress causes a reduced capability of the organism in varying the Heart Rate (and, consequently, a limited HRV). LDV was able to correctly detect this phenomenon in the time domain, while the parameters in the frequency domain show significant deviations with respect to the gold standard technique (i.e. ECG). This may be due to the movement artefacts that have consistently modified the shape of the vibration signal measured by means of LDV, after having performed the physical task. In the future, in order to avoid this drawback, the LDV technique could be used to evaluate the effects of a mental task on HRV signals (i.e. the evaluation of mental stress).

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... With Proper Contact Lens Care Apr 23, 2018 Solar Eclipse Inflicts Damage in the Shape of the ... edging closer, thanks to a wave of new technologies aiming to fix failing eye parts with human- ...

  19. Multiphoton tomography of the human eye

    Science.gov (United States)

    König, Karsten; Batista, Ana; Hager, Tobias; Seitz, Berthold

    2017-02-01

    Multiphoton tomography (MPT) is a novel label-free clinical imaging method for non-invasive tissue imaging with high spatial (300 nm) and temporal (100 ps) resolutions. In vivo optical histology can be realized due to the nonlinear excitation of endogenous fluorophores and second-harmonic generation (SHG) of collagen. Furthermore, optical metabolic imaging (OMI) is performed by two-photon autofluorescence lifetime imaging (FLIM). So far, applications of the multiphoton tomographs DermaInspect and MPTflex were limited to dermatology. Novel applications include intraoperative brain tumor imaging as well as cornea imaging. In this work we describe two-photon imaging of ex vivo human corneas unsuitable for transplantation. Furthermore, the cross-linking (CXL) process of corneal collagen based on UVA exposure and 0.1 % riboflavin was studied. The pharmacokinetics of the photosensitizer could be detected with high spatial resolution. Interestingly, an increase in the stromal autofluorescence intensity and modifications of the autofluorescence lifetimes were observed in the human corneal samples within a few days following CXL.

  20. Molecular restrictions for human eye irritation by chemical vapors

    International Nuclear Information System (INIS)

    Cometto-Muniz, J. Enrique; Cain, William S.; Abraham, Michael H.

    2005-01-01

    Previous research showed a cut-off along homologous volatile organic compounds (VOCs) in their ability to produce acute human mucosal irritation. The present study sought to specify the particular cut-off homolog for sensory eye irritation in an acetate and n-alcohol series. A 1900-ml glass vessel system and a three-alternative forced-choice procedure served to test nonyl, decyl, and dodecyl acetate, and 1-nonanol, 1-decanol, and 1-undecanol. Flowrate to the eye ranged from 2 to 8 L/min and time of exposure from 3 to 24 s. Decyl acetate and 1-undecanol were the shortest homologs that failed to produce eye irritation under all conditions, producing a cut-off effect. Increasing the vapor concentration of decyl acetate and 1-undecanol by 3 and 8 times, respectively, via heating them to 37 deg C made either or both VOCs detectable to only half of the 12 subjects tested, even though the higher vapor concentration was well above a predicted eye irritation threshold. When eye irritation thresholds for homologous acetates and n-alcohols were plotted as a function of the longest unfolded length of the molecule, the values for decyl acetate and 1-undecanol fell within a restricted range of 18 to 19 A. The outcome suggests that the basis for the cut-off is biological, that is, the molecule lacks a key size or structure to trigger transduction, rather than physical, that is, the vapor concentration is too low to precipitate detection

  1. Ray tracing for inhomogeneous media applied to the human eye

    Science.gov (United States)

    Diaz-Gonzalez, G.; Iturbe-Castillo, M. D.; Juarez-Salazar, R.

    2017-08-01

    Inhomogeneous or gradient index media exhibit a refractive index varying with the position. This kind of media are very interesting because they can be found in both synthetic as well as real life optical devices such as the human lens. In this work we present the development of a computational tool for ray tracing in refractive optical systems. Particularly, the human eye is used as the optical system under study. An inhomogeneous medium with similar characteristics to the human lens is introduced and modeled by the so-called slices method. The useful of our proposal is illustrated by several graphical results.

  2. Wavefront sensorless adaptive optics ophthalmoscopy in the human eye

    Science.gov (United States)

    Hofer, Heidi; Sredar, Nripun; Queener, Hope; Li, Chaohong; Porter, Jason

    2011-01-01

    Wavefront sensor noise and fidelity place a fundamental limit on achievable image quality in current adaptive optics ophthalmoscopes. Additionally, the wavefront sensor ‘beacon’ can interfere with visual experiments. We demonstrate real-time (25 Hz), wavefront sensorless adaptive optics imaging in the living human eye with image quality rivaling that of wavefront sensor based control in the same system. A stochastic parallel gradient descent algorithm directly optimized the mean intensity in retinal image frames acquired with a confocal adaptive optics scanning laser ophthalmoscope (AOSLO). When imaging through natural, undilated pupils, both control methods resulted in comparable mean image intensities. However, when imaging through dilated pupils, image intensity was generally higher following wavefront sensor-based control. Despite the typically reduced intensity, image contrast was higher, on average, with sensorless control. Wavefront sensorless control is a viable option for imaging the living human eye and future refinements of this technique may result in even greater optical gains. PMID:21934779

  3. How do adults and teens with self-declared Autism Spectrum Disorder experience eye contact? A qualitative analysis of first-hand accounts.

    Directory of Open Access Journals (Sweden)

    Dominic A Trevisan

    Full Text Available A tendency to avoid eye contact is an early indicator of Autism Spectrum Disorder (ASD, and difficulties with eye contact often persist throughout the lifespan. Eye contact difficulties may underlie social cognitive deficits in ASD, and can create significant social and occupational barriers. Thus, this topic has received substantial research and clinical attention. In this study, we used qualitative methods to analyze self-reported experiences with eye contact as described by teens and adults with self-declared ASD. Results suggest people with a self- declared ASD diagnosis experience adverse emotional and physiological reactions, feelings of being invaded, and sensory overload while making eye contact, in addition to difficulties understanding social nuances, and difficulties receiving and sending nonverbal information. Some data support existing mindblindness frameworks, and hyperarousal or hypoarousal theories of eye contact, but we also present novel findings unaccounted for by existing frameworks. Additionally, we highlight innovative strategies people with self-declared ASD have devised to overcome or cope with their eye contact difficulties.

  4. TU-E-201-03: Eye Lens Dosimetry in Radiotherapy Using Contact Lens-Shaped Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Park, J. [Seoul National University Hospital (Korea, Republic of)

    2015-06-15

    . These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the

  5. TU-E-201-03: Eye Lens Dosimetry in Radiotherapy Using Contact Lens-Shaped Applicator

    International Nuclear Information System (INIS)

    Park, J.

    2015-01-01

    . These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the

  6. Microwave non-contact imaging of subcutaneous human body tissues.

    Science.gov (United States)

    Kletsov, Andrey; Chernokalov, Alexander; Khripkov, Alexander; Cho, Jaegeol; Druchinin, Sergey

    2015-10-01

    A small-size microwave sensor is developed for non-contact imaging of a human body structure in 2D, enabling fitness and health monitoring using mobile devices. A method for human body tissue structure imaging is developed and experimentally validated. Subcutaneous fat tissue reconstruction depth of up to 70 mm and maximum fat thickness measurement error below 2 mm are demonstrated by measurements with a human body phantom and human subjects. Electrically small antennas are developed for integration of the microwave sensor into a mobile device. Usability of the developed microwave sensor for fitness applications, healthcare, and body weight management is demonstrated.

  7. ESTIMATION OF MELANIN CONTENT IN IRIS OF HUMAN EYE

    Directory of Open Access Journals (Sweden)

    E. A. Genina

    2008-12-01

    Full Text Available Based on the experimental data obtained in vivo from digital analysis of color images of human irises, the mean melanin content in human eye irises has been estimated. For registration of color images the digital camera Olympus C-5060 has been used. The images have been obtained from irises of healthy volunteers as well as from irises of patients with open-angle glaucoma. The computer program has been developed for digital analysis of the images. The result has been useful for development of novel methods and optimization of already existing ones for non-invasive glaucoma diagnostics.

  8. Constructing a Computer Model of the Human Eye Based on Tissue Slice Images

    OpenAIRE

    Dai, Peishan; Wang, Boliang; Bao, Chunbo; Ju, Ying

    2010-01-01

    Computer simulation of the biomechanical and biological heat transfer in ophthalmology greatly relies on having a reliable computer model of the human eye. This paper proposes a novel method on the construction of a geometric model of the human eye based on tissue slice images. Slice images were obtained from an in vitro Chinese human eye through an embryo specimen processing methods. A level set algorithm was used to extract contour points of eye tissues while a principle component analysi...

  9. Directional asymmetries in human smooth pursuit eye movements.

    Science.gov (United States)

    Ke, Sally R; Lam, Jessica; Pai, Dinesh K; Spering, Miriam

    2013-06-27

    Humans make smooth pursuit eye movements to bring the image of a moving object onto the fovea. Although pursuit accuracy is critical to prevent motion blur, the eye often falls behind the target. Previous studies suggest that pursuit accuracy differs between motion directions. Here, we systematically assess asymmetries in smooth pursuit. In experiment 1, binocular eye movements were recorded while observers (n = 20) tracked a small spot of light moving along one of four cardinal or diagonal axes across a featureless background. We analyzed pursuit latency, acceleration, peak velocity, gain, and catch-up saccade latency, number, and amplitude. In experiment 2 (n = 22), we examined the effects of spatial location and constrained stimulus motion within the upper or lower visual field. Pursuit was significantly faster (higher acceleration, peak velocity, and gain) and smoother (fewer and later catch-up saccades) in response to downward versus upward motion in both the upper and the lower visual fields. Pursuit was also more accurate and smoother in response to horizontal versus vertical motion. CONCLUSIONS. Our study is the first to report a consistent up-down asymmetry in human adults, regardless of visual field. Our findings suggest that pursuit asymmetries are adaptive responses to the requirements of the visual context: preferred motion directions (horizontal and downward) are more critical to our survival than nonpreferred ones.

  10. Isoplanatic patch of the human eye for arbitrary wavelengths

    Science.gov (United States)

    Han, Guoqing; Cao, Zhaoliang; Mu, Quanquan; Wang, Yukun; Li, Dayu; Wang, Shaoxin; Xu, Zihao; Wu, Daosheng; Hu, Lifa; Xuan, Li

    2018-03-01

    The isoplanatic patch of the human eye is a key parameter for the adaptive optics system (AOS) designed for retinal imaging. The field of view (FOV) usually sets to the same size as the isoplanatic patch to obtain high resolution images. However, it has only been measured at a specific wavelength. Here we investigate the wavelength dependence of this important parameter. An optical setup is initially designed and established in a laboratory to measure the isoplanatic patch at various wavelengths (655 nm, 730 nm and 808 nm). We established the Navarro wide-angle eye model in Zemax software to further validate our results, which suggested high consistency between the two. The isoplanatic patch as a function of wavelength was obtained within the range of visible to near-infrared, which can be expressed as: θ=0.0028 λ - 0 . 74. This work is beneficial for the AOS design for retinal imaging.

  11. Three-dimensional ray tracing for refractive correction of human eye ametropies

    Science.gov (United States)

    Jimenez-Hernandez, J. A.; Diaz-Gonzalez, G.; Trujillo-Romero, F.; Iturbe-Castillo, M. D.; Juarez-Salazar, R.; Santiago-Alvarado, A.

    2016-09-01

    Ametropies of the human eye, are refractive defects hampering the correct imaging on the retina. The most common ways to correct them is by means of spectacles, contact lenses, and modern methods as laser surgery. However, in any case it is very important to identify the ametropia grade for designing the optimum correction action. In the case of laser surgery, it is necessary to define a new shape of the cornea in order to obtain the wanted refractive correction. Therefore, a computational tool to calculate the focal length of the optical system of the eye versus variations on its geometrical parameters is required. Additionally, a clear and understandable visualization of the evaluation process is desirable. In this work, a model of the human eye based on geometrical optics principles is presented. Simulations of light rays coming from a punctual source at six meter from the cornea are shown. We perform a ray-tracing in three dimensions in order to visualize the focusing regions and estimate the power of the optical system. The common parameters of ametropies can be easily modified and analyzed in the simulation by an intuitive graphic user interface.

  12. First contacts and the common behavior of human beings

    OpenAIRE

    Van Brakel, Jaap

    2005-01-01

    In this paper my aim is to shed light on the common behavior of human beings by looking at '' first contacts '': the situation where people with unshared histories first meet (who don't speak one an others' language, don't have access to interpreters, etc.). The limits of the human life form are given by what is similar in the common behavior(s) of human beings. But what is similar should not be understood as something that is biologically or psychologically or transcendentally shared by all ...

  13. Connecting eye to eye

    DEFF Research Database (Denmark)

    Dau, Susanne; Rask, Anders Bindslev

    2017-01-01

    Computer Supported Collaborative Learning (CSCL) is used a frame for supporting online and blended learning in educations. The online communication and collaboration are afforded by the social collaboration. However, the social collaboration is based on the establishment of direct eye contact...... (Khalid, Deska & Hugenberg, 2016), but direct eye contact is challenged by the position of the digital devices and thus CSCL. Lack of eye contact is the chief contributor to the negative effects of online disinhibition (Lapidot-Lefler & Barak, 2012) and the problem is the location of the web camera...... at the computer. Eye contact is challenged by the displacement between the senders´ and receivers´ focus on the screen picture and the camera's location at the top or bottom of screens on all digital devices. The aim of this paper is accordingly to investigate the influence of the displacement in eye contact...

  14. Nature Contact and Human Health: A Research Agenda.

    Science.gov (United States)

    Frumkin, Howard; Bratman, Gregory N; Breslow, Sara Jo; Cochran, Bobby; Kahn, Peter H; Lawler, Joshua J; Levin, Phillip S; Tandon, Pooja S; Varanasi, Usha; Wolf, Kathleen L; Wood, Spencer A

    2017-07-31

    At a time of increasing disconnectedness from nature, scientific interest in the potential health benefits of nature contact has grown. Research in recent decades has yielded substantial evidence, but large gaps remain in our understanding. We propose a research agenda on nature contact and health, identifying principal domains of research and key questions that, if answered, would provide the basis for evidence-based public health interventions. We identify research questions in seven domains: a ) mechanistic biomedical studies; b ) exposure science; c ) epidemiology of health benefits; d ) diversity and equity considerations; e ) technological nature; f ) economic and policy studies; and g ) implementation science. Nature contact may offer a range of human health benefits. Although much evidence is already available, much remains unknown. A robust research effort, guided by a focus on key unanswered questions, has the potential to yield high-impact, consequential public health insights. https://doi.org/10.1289/EHP1663.

  15. Accuracy and reliability of the Keeler Pulsair EasyEye non-contact tonometer.

    Science.gov (United States)

    Ogbuehi, Kelechi C; Almubrad, Turki M

    2008-01-01

    To evaluate the accuracy and reliability of the Keeler Pulsair EasyEye noncontact tonometer in a normotensive population. This masked prospective clinical study included 72 right eyes of 72 subjects. Two sets of intraocular pressure measurements were made 1 week apart. Intraocular pressure assessment with the Goldmann tonometer was always subsequent to that with the noncontact tonometer. Each method was assessed for within-session and test-retest repeatability and both methods were assessed for limits of agreement, twice. The level of significance for this study was 0.05. Both methods were repeatable within-sessions to within +/-2 mm Hg, and between sessions to within +/-3 mm Hg. Neither the within-session differences nor the between session differences differed significantly between the Goldmann tonometer and the Pulsair EasyEye noncontact tonometer. The mean differences (+/-SD) between both methods (0.1 +/- 1.6 mm Hg and 0.05 +/- 1.7 mm Hg, for the first and second sessions, respectively) were not statistically significant, but the intraocular pressure measured with the Pulsair EasyEye tonometer was consistently higher than that measured with the Goldmann tonometer. The Pulsair EasyEye noncontact tonometer is considered an accurate reliable method in the normotensive population studied but because of a systematic bias in a small number of subjects, it cannot be used interchangeably with the Goldmann tonometer.

  16. Eye movements reveal epistemic curiosity in human observers.

    Science.gov (United States)

    Baranes, Adrien; Oudeyer, Pierre-Yves; Gottlieb, Jacqueline

    2015-12-01

    Saccadic (rapid) eye movements are primary means by which humans and non-human primates sample visual information. However, while saccadic decisions are intensively investigated in instrumental contexts where saccades guide subsequent actions, it is largely unknown how they may be influenced by curiosity - the intrinsic desire to learn. While saccades are sensitive to visual novelty and visual surprise, no study has examined their relation to epistemic curiosity - interest in symbolic, semantic information. To investigate this question, we tracked the eye movements of human observers while they read trivia questions and, after a brief delay, were visually given the answer. We show that higher curiosity was associated with earlier anticipatory orienting of gaze toward the answer location without changes in other metrics of saccades or fixations, and that these influences were distinct from those produced by variations in confidence and surprise. Across subjects, the enhancement of anticipatory gaze was correlated with measures of trait curiosity from personality questionnaires. Finally, a machine learning algorithm could predict curiosity in a cross-subject manner, relying primarily on statistical features of the gaze position before the answer onset and independently of covariations in confidence or surprise, suggesting potential practical applications for educational technologies, recommender systems and research in cognitive sciences. With this article, we provide full access to the annotated database allowing readers to reproduce the results. Epistemic curiosity produces specific effects on oculomotor anticipation that can be used to read out curiosity states. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. A comparison of the Goldmann applanation and non-contact (Keeler Pulsair EasyEye) tonometers and the effect of central corneal thickness in indigenous African eyes.

    Science.gov (United States)

    Babalola, O E; Kehinde, A V; Iloegbunam, A C; Akinbinu, T; Moghalu, C; Onuoha, I

    2009-03-01

    The Keeler Pulsair EasyEye non-contact tonometer (NCT) was introduced into practice at Rachel Eye Center Abuja, Nigeria, where the patients are indigenous Africans. This was compared to the 'gold standard' Goldmann applanation tonometer (GAT) to determine if the instrument was accurate in Africans, with particular reference to the influence of central corneal thickness (CCT). 174 eyes of 88 patients were analysed. Pachymetry was performed using Sonomed PacScan AP300, and GAT with the Haag Streit R-900. Pachymetric corrections of NCT (NCTc) and GAT (GATc) were carried out with the Sonomed algorithm. Pearson's correlation r, linear regression analysis, Student t-test and Bland-Altman analysis were used to compare the instruments. Mean NCT readings were similar (17.36 mmHg) to mean GAT (17.42 mmHg; p = 0.769). GAT/NCT correlation coefficient, r, was 0.883 as compared with 0.868 for GATc/NCTc. The linear regression equation was GAT = 2.79 + 0.84*NCT (r(2) = 0.78). Forty-five per cent of differences were within 1 mmHg, while 79% were within 3 mmHg. This was similar to findings in some studies on Caucasians. Bland-Altman analysis however suggested that the spread of differences was wider than in those studies. Outliers (differences more than 5 mmHg) sometimes reflected difficulties encountered with GAT in routine practice. Mean CCT was 537.9 microm, (S.D. 38.4, 95% confidence interval 532.1-543.7 microm) and CCT appeared lower than in Caucasians. Both GAT and NCT IOP tended to rise with increasing CCT but NCT had a greater tendency to do so. Regression analysis suggested that NCT IOP increased by 0.6 mmHg for every 10 mum increase in CCT, compared to 0.4 mmHg for GAT. Thirty-eight per cent of the patients preferred NCT as opposed to 25% GAT. The Keeler Pulsair EasyEye gives reliable measurements of IOP in African eyes but is significantly affected by CCT. Particularly in borderline cases where management decisions have to be taken, it may be necessary to have pachymetric

  18. Electron dose distributions caused by the contact-type metallic eye shield: Studies using Monte Carlo and pencil beam algorithms.

    Science.gov (United States)

    Kang, Sei-Kwon; Yoon, Jai-Woong; Hwang, Taejin; Park, Soah; Cheong, Kwang-Ho; Han, Tae Jin; Kim, Haeyoung; Lee, Me-Yeon; Kim, Kyoung Ju; Bae, Hoonsik

    2015-01-01

    A metallic contact eye shield has sometimes been used for eyelid treatment, but dose distribution has never been reported for a patient case. This study aimed to show the shield-incorporated CT-based dose distribution using the Pinnacle system and Monte Carlo (MC) calculation for 3 patient cases. For the artifact-free CT scan, an acrylic shield machined as the same size as that of the tungsten shield was used. For the MC calculation, BEAMnrc and DOSXYZnrc were used for the 6-MeV electron beam of the Varian 21EX, in which information for the tungsten, stainless steel, and aluminum material for the eye shield was used. The same plan was generated on the Pinnacle system and both were compared. The use of the acrylic shield produced clear CT images, enabling delineation of the regions of interest, and yielded CT-based dose calculation for the metallic shield. Both the MC and the Pinnacle systems showed a similar dose distribution downstream of the eye shield, reflecting the blocking effect of the metallic eye shield. The major difference between the MC and the Pinnacle results was the target eyelid dose upstream of the shield such that the Pinnacle system underestimated the dose by 19 to 28% and 11 to 18% for the maximum and the mean doses, respectively. The pattern of dose difference between the MC and the Pinnacle systems was similar to that in the previous phantom study. In conclusion, the metallic eye shield was successfully incorporated into the CT-based planning, and the accurate dose calculation requires MC simulation. Copyright © 2015 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  19. Differential Deposition of Fluorescently Tagged Cholesterol on Commercial Contact Lenses Using a Novel In Vitro Eye Model.

    Science.gov (United States)

    Walther, Hendrik; Phan, Chau-Minh; Subbaraman, Lakshman N; Jones, Lyndon

    2018-04-01

    We evaluate the differences in lipid uptake and penetration in daily disposable (DD) contact lenses (CL) using a conventional "in-vial" method compared to a novel in vitro eye model. The penetration of fluorescently labelled 22-(N-(7-Nitrobenz-2-Oxa-1,3-Diazol-4-yl)Amino)-23,24-Bisnor-5-Cholen-3beta-Ol (NBD)-cholesterol on three silicone hydrogel (SH) and four conventional hydrogel (CH) DD CLs were investigated. CLs were incubated for 4 and 12 hours in a vial, containing 3.5 mL artificial tear solution (ATS), or were mounted on an in vitro eye-blink platform designed to simulate physiologic tear flow (2 mL/24 hours), tear volume and "simulated" blinking. Subsequently, CLs were analyzed using laser scanning confocal microscopy and ImageJ. Penetration depth and fluorescence intensities of NBD-cholesterol varied between the incubation methods as well as lens materials. Using the traditional vial incubation method, NBD-cholesterol uptake occurred equally on both sides of all lens materials. However, using our eye-blink model, cholesterol penetration was observed primarily on the anterior surface of the CLs. In general, SH lenses showed higher intensities of NBD-cholesterol than CH materials. The traditional "in-vial" incubation method exposes the CLs to an excessively high amount of ATS, which results in an overestimation for cholesterol deposition. Our model, which incorporates important ocular factors, such as intermittent air exposure, small tear volume, and physiological tear flow between blinks, provides a more natural environment for in vitro lens incubation. In vitro measurements of CLs are a common approach to predict their interactions and performance on the eye. Traditional methods, however, are rudimentary. Therefore, this study presents a novel in vitro model to evaluate CLs, which consequently will enhance elucidations of the interactions between CLs and the eye.

  20. Electron dose distributions caused by the contact-type metallic eye shield: Studies using Monte Carlo and pencil beam algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Sei-Kwon; Yoon, Jai-Woong; Hwang, Taejin; Park, Soah; Cheong, Kwang-Ho; Jin Han, Tae; Kim, Haeyoung; Lee, Me-Yeon; Ju Kim, Kyoung, E-mail: kjkim@hallym.or.kr; Bae, Hoonsik

    2015-10-01

    A metallic contact eye shield has sometimes been used for eyelid treatment, but dose distribution has never been reported for a patient case. This study aimed to show the shield-incorporated CT-based dose distribution using the Pinnacle system and Monte Carlo (MC) calculation for 3 patient cases. For the artifact-free CT scan, an acrylic shield machined as the same size as that of the tungsten shield was used. For the MC calculation, BEAMnrc and DOSXYZnrc were used for the 6-MeV electron beam of the Varian 21EX, in which information for the tungsten, stainless steel, and aluminum material for the eye shield was used. The same plan was generated on the Pinnacle system and both were compared. The use of the acrylic shield produced clear CT images, enabling delineation of the regions of interest, and yielded CT-based dose calculation for the metallic shield. Both the MC and the Pinnacle systems showed a similar dose distribution downstream of the eye shield, reflecting the blocking effect of the metallic eye shield. The major difference between the MC and the Pinnacle results was the target eyelid dose upstream of the shield such that the Pinnacle system underestimated the dose by 19 to 28% and 11 to 18% for the maximum and the mean doses, respectively. The pattern of dose difference between the MC and the Pinnacle systems was similar to that in the previous phantom study. In conclusion, the metallic eye shield was successfully incorporated into the CT-based planning, and the accurate dose calculation requires MC simulation.

  1. Comparing fMRI activation during smooth pursuit eye movements among contact sport athletes, non-contact sport athletes, and non-athletes

    Directory of Open Access Journals (Sweden)

    Derek Kellar

    Full Text Available Objectives: Though sub-concussive impacts are common during contact sports, there is little consensus whether repeat blows affect brain function. Using a “lifetime exposure” rather than acute exposure approach, we examined oculomotor performance and brain activation among collegiate football players and two control groups. Our analysis examined whether there are group differences in eye movement behavioral performance and in brain activation during smooth pursuit. Methods: Data from 21 off-season Division I football “starters” were compared with a 19 collegiate cross-country runners, and b 11 non-athlete college students who were SES matched to the football player group (total N = 51. Visual smooth pursuit was performed while undergoing fMRI imaging via a 3 Tesla scanner. Smooth pursuit eye movements to three stimulus difficulty levels were measured with regard to RMS error, gain, and lag. Results: No meaningful differences were found for any of the standard analyses used to assess smooth pursuit eye movements. For fMRI, greater activation was seen in the oculomotor region of the cerebellar vermis and areas of the FEF for football players as compared to either control group, who did not differ on any measure. Conclusion: Greater cerebellar activity among football players while performing an oculomotor task could indicate that they are working harder to compensate for some subtle, long-term subconcussive deficits. Alternatively, top athletes in a sport requiring high visual motor skill could have more of their cerebellum and FEF devoted to oculomotor task performance regardless of subconcussive history. Overall, these results provide little firm support for an effect of accumulated subconcussion exposure on brain function. Keywords: Smooth pursuit, fMRI, Collegiate athletics

  2. A boundary element model for investigating the effects of eye tumor on the temperature distribution inside the human eye.

    Science.gov (United States)

    Ooi, E H; Ang, W T; Ng, E Y K

    2009-08-01

    A three-dimensional boundary element model of the human eye is developed to investigate the thermal effects of eye tumor on the ocular temperature distribution. The human eye is modeled as comprising several regions which have different thermal properties. The tumor is one of these regions. The thermal effects of the tumor are simulated by taking it to have a very high metabolic heat generation and blood perfusion rate. Inside the tumor, the steady state temperature is governed by the Pennes bioheat equation. Elsewhere, in normal tissues of the eye, the temperature satisfies the Laplace's equation. To compute the temperature on the corneal surface, the surface boundary of each region is divided into triangular elements.

  3. Comparative Analysis of Gene Expression for Convergent Evolution of Camera Eye Between Octopus and Human

    Science.gov (United States)

    Ogura, Atsushi; Ikeo, Kazuho; Gojobori, Takashi

    2004-01-01

    Although the camera eye of the octopus is very similar to that of humans, phylogenetic and embryological analyses have suggested that their camera eyes have been acquired independently. It has been known as a typical example of convergent evolution. To study the molecular basis of convergent evolution of camera eyes, we conducted a comparative analysis of gene expression in octopus and human camera eyes. We sequenced 16,432 ESTs of the octopus eye, leading to 1052 nonredundant genes that have matches in the protein database. Comparing these 1052 genes with 13,303 already-known ESTs of the human eye, 729 (69.3%) genes were commonly expressed between the human and octopus eyes. On the contrary, when we compared octopus eye ESTs with human connective tissue ESTs, the expression similarity was quite low. To trace the evolutionary changes that are potentially responsible for camera eye formation, we also compared octopus-eye ESTs with the completed genome sequences of other organisms. We found that 1019 out of the 1052 genes had already existed at the common ancestor of bilateria, and 875 genes were conserved between humans and octopuses. It suggests that a larger number of conserved genes and their similar gene expression may be responsible for the convergent evolution of the camera eye. PMID:15289475

  4. IOP measurement in silicone oil tamponade eyes by Corvis ST tonometer, Goldmann applanation tonometry and non-contact tonometry.

    Science.gov (United States)

    Zhang, Yang; Zheng, Lin; Bian, Ailing; Zhou, Qi

    2018-04-01

    To compare the postoperative intraocular pressure (IOP) of eyes following pars plana vitrectomy (PPV) combined with intravitreal silicone oil (SO) tamponade by Corneal Visualization Scheimpflug Technology (CST), Goldmann applanation tonometry (GAT) and non-contact tonometry (NCT). Thirty-eight participants who had undergone PPV combined with SO tamponade to treat vitreoretinal diseases were enrolled. Postoperative IOP measurements were obtained using CST, NCT and GAT. Inter-device agreement was assessed by Bland-Altman analysis. The correlation coefficient was used to describe the potential postoperative factors affecting the postoperative IOP differences between each device. Bland-Altman analysis revealed the bias between CST and GAT, between CST and NCT, and between GAT and NCT to be -0.2, 2.1 and 2.4 mmHg, respectively. CST and GAT correlated well with each other. NCT values were lower than those of GAT and CST (all p contact method for measuring postoperative IOP in SO tamponade eyes.

  5. Generating Virtual Eye Contacts Through Online Synchronous Communications in Virtual Classroom Applications

    OpenAIRE

    T. Volkan YUZER

    2007-01-01

    The Internet usage has been increasing among persons in the worldwide. This situation highlights that the number of potential distance learners has been increasing in the Internet society. Besides, the terms and concepts of the Internet environments become to be spread out in this society like virtual reality. It is also possible to explain the characters of the Internet clearly via generating relatively new terms or concepts. “Virtual eye contact” concept is one of these. In this article, th...

  6. Genetic analyses of the human eye colours using a novel objective method for eye colour classification

    DEFF Research Database (Denmark)

    Andersen, Jeppe D.; Johansen, Peter; Harder, Stine

    2013-01-01

    In this study, we present a new objective method for measuring the eye colour on a continuous scale that allows researchers to associate genetic markers with different shades of eye colour. With the use of the custom designed software Digital Iris Analysis Tool (DIAT), the iris was automatically...... and TYR rs1393350) on the eye colour. We evaluated the two published prediction models for eye colour (IrisPlex [1] and Snipper[2]) and compared the predictions with the PIE-scores. We found good concordance with the prediction from individuals typed as HERC2 rs12913832 G. However, both methods had......-score ranged from −1 to 1 (brown to blue). The software eliminated the need for user based interpretation and qualitative eye colour categories. In 94% (570) of 605 analyzed eye images, the iris region was successfully extracted and a PIE-score was calculated. A very high correlation between the PIE...

  7. Can human eyes prevent perceptual narrowing for monkey faces in human infants?

    Science.gov (United States)

    Damon, Fabrice; Bayet, Laurie; Quinn, Paul C; Hillairet de Boisferon, Anne; Méary, David; Dupierrix, Eve; Lee, Kang; Pascalis, Olivier

    2015-07-01

    Perceptual narrowing has been observed in human infants for monkey faces: 6-month-olds can discriminate between them, whereas older infants from 9 months of age display difficulty discriminating between them. The difficulty infants from 9 months have processing monkey faces has not been clearly identified. It could be due to the structural characteristics of monkey faces, particularly the key facial features that differ from human faces. The current study aimed to investigate whether the information conveyed by the eyes is of importance. We examined whether the presence of Caucasian human eyes in monkey faces allows recognition to be maintained in 6-month-olds and facilitates recognition in 9- and 12-month-olds. Our results revealed that the presence of human eyes in monkey faces maintains recognition for those faces at 6 months of age and partially facilitates recognition of those faces at 9 months of age, but not at 12 months of age. The findings are interpreted in the context of perceptual narrowing and suggest that the attenuation of processing of other-species faces is not reversed by the presence of human eyes. © 2015 Wiley Periodicals, Inc.

  8. Human vertical eye movement responses to earth horizontal pitch

    Science.gov (United States)

    Wall, C. 3rd; Petropoulos, A. E.

    1993-01-01

    The vertical eye movements in humans produced in response to head-over-heels constant velocity pitch rotation about a horizontal axis resemble those from other species. At 60 degrees/s these are persistent and tend to have non-reversing slow components that are compensatory to the direction of rotation. In most, but not all subjects, the slow component velocity was well characterized by a rapid build-up followed by an exponential decay to a non-zero baseline. Super-imposed was a cyclic or modulation component whose frequency corresponded to the time for one revolution and whose maximum amplitude occurred during a specific head orientation. All response components (exponential decay, baseline and modulation) were larger during pitch backward compared to pitch forward runs. Decay time constants were shorter during the backward runs, thus, unlike left to right yaw axis rotation, pitch responses display significant asymmetries between paired forward and backward runs.

  9. Noninvasive detection of macular pigments in the human eye.

    Science.gov (United States)

    Gellermann, Werner; Bernstein, Paul S

    2004-01-01

    There is currently strong interest in developing noninvasive technologies for the detection of macular carotenoid pigments in the human eye. These pigments, consisting of lutein and zeaxanthin, are taken up from the diet and are thought to play an important role in the prevention of age-related macular degeneration, the leading cause of blindness in the elderly in the Western world. It may be possible to prevent or delay the onset of this debilitating disease with suitable dietary intervention strategies. We review the most commonly used detection techniques based on heterochromatic flicker photometry, fundus reflectometry, and autofluorescense techniques and put them in perspective with recently developed more molecule-specific Raman detection methods. (c) 2004 Society of Photo-Optical Instrumentation Engineers.

  10. Composite modified Luneburg model of human eye lens.

    Science.gov (United States)

    Gómez-Correa, J E; Balderas-Mata, S E; Pierscionek, B K; Chávez-Cerda, S

    2015-09-01

    A new lens model based on the gradient-index Luneburg lens and composed of two oblate half spheroids of different curvatures is presented. The spherically symmetric Luneburg lens is modified to create continuous isoindicial contours and to incorporate curvatures that are similar to those found in a human lens. The imaging capabilities of the model and the changes in the gradient index profile are tested for five object distances, for a fixed geometry and for a fixed image distance. The central refractive index decreases with decreasing object distance. This indicates that in order to focus at the same image distance as is required in the eye, a decrease in refractive power is needed for rays from closer objects that meet the lens surface at steeper angles compared to rays from more distant objects. This ensures a highly focused image with no spherical aberration.

  11. Monte-Carlo simulation of proton radiotherapy for human eye

    International Nuclear Information System (INIS)

    Liu Yunpeng; Tang Xiaobin; Xie Qin; Chen Feida; Geng Changran; Chen Da

    2010-01-01

    The 62 MeV proton beam was selected to develop a MCNPX model of the human eye to approximate dose delivered from proton therapy by. In the course of proton therapy, two treatment simulations were considered. The first simulation was an ideal treatment scenario. In this case, the dose of tumor was 50.03 Gy, which was at the level of effective treatment, while other organizations were in the range of acceptable dose. The second case was a worst case scenario to simulate a patient gazing directly into the treatment beam during therapy. The bulk of dose deposited in the cornea, lens, and anterior chamber region. However, the dose of tumor area was zero. The calculated results show an agreement accordance with the relative reference, which confirmed that the MCNPX code can simulate proton radiotherapy perfectly, and is a capable platform for patient planning. The data from the worst case can be used for dose reconstruction of the clinical accident. (authors)

  12. Human behavioral biology: commentary on Lerner and von Eye's sociobiology and human development

    NARCIS (Netherlands)

    Molenaar, P.C.M.; Burgess, R.L.

    1993-01-01

    Contends that in their examination of arguments forwarded by sociobiologists to account for key features of human development, R. M. Lerner and A. von Eye (see record 1992-23071-001) misunderstand the role of general theory in science. They also fail to characterize the work of sociobiologists

  13. Visual Positioning Indoors: Human Eyes vs. Smartphone Cameras.

    Science.gov (United States)

    Wu, Dewen; Chen, Ruizhi; Chen, Liang

    2017-11-16

    Artificial Intelligence (AI) technologies and their related applications are now developing at a rapid pace. Indoor positioning will be one of the core technologies that enable AI applications because people spend 80% of their time indoors. Humans can locate themselves related to a visually well-defined object, e.g., a door, based on their visual observations. Can a smartphone camera do a similar job when it points to an object? In this paper, a visual positioning solution was developed based on a single image captured from a smartphone camera pointing to a well-defined object. The smartphone camera simulates the process of human eyes for the purpose of relatively locating themselves against a well-defined object. Extensive experiments were conducted with five types of smartphones on three different indoor settings, including a meeting room, a library, and a reading room. Experimental results shown that the average positioning accuracy of the solution based on five smartphone cameras is 30.6 cm, while that for the human-observed solution with 300 samples from 10 different people is 73.1 cm.

  14. Non-contact biopotential sensor for remote human detection

    Energy Technology Data Exchange (ETDEWEB)

    Mahdi, A E [Department of Electronic and Computer Engineering, University of Limerick, Limerick (Ireland); Faggion, L, E-mail: hussain.mahdi@ul.ie, E-mail: lorenzo.faggion@jrc.ec.europa.eu [Joint Research Centre of the European Commission, Institute for the Protection and Safety of the Citizen, Ispra (Italy)

    2011-08-17

    This paper describes a new low-cost, low-noise displacement current sensor developed for non-contact measurements of human biopotentials and well suited for detection of human presence applications. The sensor employs a simple, improvised transimpedance amplifier that eliminates the need for ultra high values resistors normally needed in current amplifiers required for this type of measurements. The sensor provides an operational bandwidth of 0.5 - 250 Hz, and a noise level of 7.8{mu}V{radical}Hz at 1 Hz down to 30nV/{radical}Hz at 1 kHz. Reported experimental results demonstrate the sensor's capability in measuring heart related biopotentials within 0.5m off-body distance, and muscle related biopotentials within 10m no obstacles off-body distance, and 5m off-body distance with a concrete wall in between.

  15. Blue eyes in lemurs and humans: same phenotype, different genetic mechanism

    DEFF Research Database (Denmark)

    Bradley, Brenda J; Pedersen, Anja; Mundy, Nicholas I

    2009-01-01

    Almost all mammals have brown or darkly-pigmented eyes (irises), but among primates, there are some prominent blue-eyed exceptions. The blue eyes of some humans and lemurs are a striking example of convergent evolution of a rare phenotype on distant branches of the primate tree. Recent work...... on humans indicates that blue eye color is associated with, and likely caused by, a single nucleotide polymorphism (rs12913832) in an intron of the gene HERC2, which likely regulates expression of the neighboring pigmentation gene OCA2. This raises the immediate question of whether blue eyes in lemurs might...... have a similar genetic basis. We addressed this by sequencing the homologous genetic region in the blue-eyed black lemur (Eulemur macaco flavifrons; N = 4) and the closely-related black lemur (Eulemur macaco macaco; N = 4), which has brown eyes. We then compared a 166-bp segment corresponding...

  16. Generating Virtual Eye Contacts Through Online Synchronous Communications in Virtual Classroom Applications

    Directory of Open Access Journals (Sweden)

    T. Volkan YUZER

    2007-01-01

    Full Text Available The Internet usage has been increasing among persons in the worldwide. This situation highlights that the number of potential distance learners has been increasing in the Internet society. Besides, the terms and concepts of the Internet environments become to be spread out in this society like virtual reality. It is also possible to explain the characters of the Internet clearly via generating relatively new terms or concepts. “Virtual eye contact” concept is one of these. In this article, this concept is considered with a specific application of synchronous internet-based e-learning environments which is virtual classroom platform application. Explanation, technological infrastructure and benefits of this concept and training of the trainers to use this nonverbal communication type more powerfully are explained and discussed.

  17. A Pseudomonas aeruginosa strain isolated from a contact lens-induced acute red eye (CLARE) is protease-deficient.

    Science.gov (United States)

    Estrellas, P S; Alionte, L G; Hobden, J A

    2000-03-01

    Pseudomonas aeruginosa proteases are thought to be important virulence factors in the pathogenesis of corneal disease. This study examined protease production from two strains of P. aeruginosa responsible for two very distinct clinical diseases: strain Paer1, isolated from a Contact Lens-induced Acute Red Eye (CLARE), and strain KEI 1025, isolated from a corneal ulcer. Strains were compared to a laboratory strain (ATCC 19660) known to produce severe keratitis in experimentally infected mice for protease production and for ocular virulence. Protease production was examined with colorimetric assays, gelatin zymography and western blots. Elastase A activity was quantitated with a staphylolytic assay. Ocular virulence was examined using a mouse scratch model of keratitis. In contrast to strains KEI 1025 or ATCC 19660, Paer1 was unable to produce enzymatically active elastase A, elastase, and protease IV. All three strains produced active alkaline protease. Strains KEI 1025 and ATCC 19660 produced a fulminant keratitis in mice whereas Paer1 produced a mild transient infection. Restoration of elastase activity in Paer1 via genetic complementation did not result in a virulent phenotype. Co-infection of mouse eyes with strains Paer1 and ATCC 19660 resulted in the eventual loss of Paer1 from corneal tissue. These studies suggest that P. aeruginosa elastase A and/or protease IV, but not alkaline protease or elastase, contribute to the ocular virulence of this organism.

  18. Controlled delivery of antiangiogenic drug to human eye tissue using a MEMS device

    KAUST Repository

    Pirmoradi, Fatemeh Nazly; Ou, Kevin; Jackson, John K.; Letchford, Kevin; Cui, Jing; Wolf, Ki Tae; Graber, Florian; Zhao, Tom; Matsubara, Joanne A.; Burt, Helen; Chiao, Mu; Lin, Liwei

    2013-01-01

    We demonstrate an implantable MEMS drug delivery device to conduct controlled and on-demand, ex vivo drug transport to human eye tissue. Remotely operated drug delivery to human post-mortem eyes was performed via a MEMS device. The developed curved

  19. Contact with nature and children’s restorative experiences: an eye to the future

    Directory of Open Access Journals (Sweden)

    Silvia Collado

    2016-11-01

    Full Text Available This article offers an overview of what has been done until now on restorative research with children and opens up new inquires for future research. Most of the work has studied children’s exposure to nature and the restorative benefits this contact provides, focusing on the renewal of children’s psychological resources. The paper begins with an introduction to children’s current tendency toward an alienation from the natural world and sets out the objectives of the article. It is followed by four main sections. The first two sections report on what we already know in this research area, distinguishing between children with normal mental capabilities and those suffering from attention-deficit hyperactivity disorder (ADHD. The findings gathered in these sections suggest that children’s contact with nature improves their mood and their cognitive functioning, increases their social interactions and reduces ADHD symptoms. The next section describes five suggestions for future research: 1 the need for considering the relational dynamics between the child and the environment in restoration research, and the concept of constrained restoration; 2 the possibility of restorative needs arising from understimulation; 3 the importance of considering children’s social context for restoration; 4 the relationship between restoration and pro-social and pro-environmental behaviors and 5 children’s restorative environments other than nature. We close by making some final remarks about the importance of restoring daily depleted resources for children’s healthy functioning.

  20. Different cellular effects of four anti-inflammatory eye drops on human corneal epithelial cells: independent in active components

    OpenAIRE

    Qu, Mingli; Wang, Yao; Yang, Lingling; Zhou, Qingjun

    2011-01-01

    Purpose To evaluate and compare the cellular effects of four commercially available anti-inflammatory eye drops and their active components on human corneal epithelial cells (HCECs) in vitro. Methods The cellular effects of four eye drops (Bromfenac Sodium Hydrate Eye Drops, Pranoprofen Eye Drops, Diclofenac Sodium Eye Drops, and Tobramycin & Dex Eye Drops) and their corresponding active components were evaluated in an HCEC line with five in vitro assays. Cell proliferation and migration were...

  1. Implicit prosody mining based on the human eye image capture technology

    Science.gov (United States)

    Gao, Pei-pei; Liu, Feng

    2013-08-01

    The technology of eye tracker has become the main methods of analyzing the recognition issues in human-computer interaction. Human eye image capture is the key problem of the eye tracking. Based on further research, a new human-computer interaction method introduced to enrich the form of speech synthetic. We propose a method of Implicit Prosody mining based on the human eye image capture technology to extract the parameters from the image of human eyes when reading, control and drive prosody generation in speech synthesis, and establish prosodic model with high simulation accuracy. Duration model is key issues for prosody generation. For the duration model, this paper put forward a new idea for obtaining gaze duration of eyes when reading based on the eye image capture technology, and synchronous controlling this duration and pronunciation duration in speech synthesis. The movement of human eyes during reading is a comprehensive multi-factor interactive process, such as gaze, twitching and backsight. Therefore, how to extract the appropriate information from the image of human eyes need to be considered and the gaze regularity of eyes need to be obtained as references of modeling. Based on the analysis of current three kinds of eye movement control model and the characteristics of the Implicit Prosody reading, relative independence between speech processing system of text and eye movement control system was discussed. It was proved that under the same text familiarity condition, gaze duration of eyes when reading and internal voice pronunciation duration are synchronous. The eye gaze duration model based on the Chinese language level prosodic structure was presented to change previous methods of machine learning and probability forecasting, obtain readers' real internal reading rhythm and to synthesize voice with personalized rhythm. This research will enrich human-computer interactive form, and will be practical significance and application prospect in terms of

  2. A scalable and deformable stylized model of the adult human eye for radiation dose assessment.

    Science.gov (United States)

    El Basha, Daniel; Furuta, Takuya; Iyer, Siva S R; Bolch, Wesley E

    2018-03-23

    With recent changes in the recommended annual limit on eye lens exposures to ionizing radiation, there is considerable interest in predictive computational dosimetry models of the human eye and its various ocular structures including the crystalline lens, ciliary body, cornea, retina, optic nerve, and central retinal artery. Computational eye models to date have been constructed as stylized models, high-resolution voxel models, and polygon mesh models. Their common feature, however, is that they are typically constructed of nominal size and of a roughly spherical shape associated with the emmetropic eye. In this study, we present a geometric eye model that is both scalable (allowing for changes in eye size) and deformable (allowing for changes in eye shape), and that is suitable for use in radiation transport studies of ocular exposures and radiation treatments of eye disease. The model allows continuous and variable changes in eye size (axial lengths from 20 to 26 mm) and eye shape (diopters from -12 to +6). As an explanatory example of its use, five models (emmetropic eyes of small, average, and large size, as well as average size eyes of -12D and +6D) were constructed and subjected to normally incident beams of monoenergetic electrons and photons, with resultant energy-dependent dose coefficients presented for both anterior and posterior eye structures. Electron dose coefficients were found to vary with changes to both eye size and shape for the posterior eye structures, while their values for the eye crystalline lens were found to be sensitive to changes in only eye size. No dependence upon eye size or eye shape was found for photon dose coefficients at energies below 2 MeV. Future applications of the model can include more extensive tabulations of dose coefficients to all ocular structures (not only the lens) as a function of eye size and shape, as well as the assessment of x-ray therapies for ocular disease for patients with non-emmetropic eyes. © 2018

  3. Intraocular Telescopic System Design: Optical and Visual Simulation in a Human Eye Model

    OpenAIRE

    Zoulinakis, Georgios; Ferrer-Blasco, Teresa

    2017-01-01

    Purpose. To design an intraocular telescopic system (ITS) for magnifying retinal image and to simulate its optical and visual performance after implantation in a human eye model. Methods. Design and simulation were carried out with a ray-tracing and optical design software. Two different ITS were designed, and their visual performance was simulated using the Liou-Brennan eye model. The difference between the ITS was their lenses’ placement in the eye model and their powers. Ray tracing in bot...

  4. The Influences of Face Inversion and Facial Expression on Sensitivity to Eye Contact in High-Functioning Adults with Autism Spectrum Disorders

    Science.gov (United States)

    Vida, Mark D.; Maurer, Daphne; Calder, Andrew J.; Rhodes, Gillian; Walsh, Jennifer A.; Pachai, Matthew V.; Rutherford, M. D.

    2013-01-01

    We examined the influences of face inversion and facial expression on sensitivity to eye contact in high-functioning adults with and without an autism spectrum disorder (ASD). Participants judged the direction of gaze of angry, fearful, and neutral faces. In the typical group only, the range of directions of gaze leading to the perception of eye…

  5. Effect of Virtual Reality Exposure and Aural Stimuli on Eye Contact, Directional Focus, and Focus of Attention of Novice Wind Band Conductors

    Science.gov (United States)

    Orman, Evelyn K.

    2016-01-01

    This study examined the effects of virtual reality immersion with audio on eye contact, directional focus and focus of attention for novice wind band conductors. Participants (N = 34) included a control group (n = 12) and two virtual reality groups with (n = 10) and without (n = 12) head tracking. Participants completed conducting/score study…

  6. Application of SV40 T-transformed human corneal epithelial cells to evaluate potential irritant chemicals for in vitro alternative eye toxicity.

    Science.gov (United States)

    Kim, Cho-Won; Park, Geon-Tae; Bae, Ok-Nam; Noh, Minsoo; Choi, Kyung-Chul

    2016-01-01

    Assessment of eye irritation potential is important to human safety, and it is necessary for various cosmetics and chemicals that may contact the human eye. Until recently, the Draize test was considered the standard method for estimating eye irritation, despite its disadvantages such as the need to sacrifice many rabbits for subjective scoring. Thus, we investigated the cytotoxicity and inflammatory response to standard eye irritants using SV40 T-transformed human corneal epithelial (SHCE) cells as a step toward development of an animal-free alternative eye irritation test. MTT and NRU assays of cell viability were performed to investigate the optimal experimental conditions for SHCE cell viability when cells were exposed to sodium dodecyl sulfate (SDS) as a standard eye irritant at 6.25×10(-3) to 1×10(-1)%. Additionally, cell viability of SHCE cells was examined in response to six potential eye irritants, benzalkonium chloride, dimethyl sulfoxide, isopropanol, SDS, Triton X-100 and Tween 20 at 5×10(-3) to 1×10(-1)%. Finally, we estimated the secretion level of cytokines in response to stimulation by eye irritants in SHCE cells. SHCE cells showed a good response to potential eye irritants when the cells were exposed to potential irritants for 10min at room temperature (RT), and cytokine production increased in a concentration-dependent manner, indicating that cytotoxicity and cytokine secretion from SHCE cells may be well correlated with the concentrations of irritants. Taken together, these results suggest that SHCE cells could be an excellent alternative in vitro model to replace in vivo animal models for eye irritation tests. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Human eye modelling for ophthalmic simulators project for clinic applications

    International Nuclear Information System (INIS)

    Sanchez, Andrea; Santos, Adimir dos; Yoriyaz, Helio

    2002-01-01

    Most of eye tumors are treated by surgical means, which involves the enucleation of affected eyes. In terms of treatment and control of diseases, there is brachytherapy, which often utilizes small applicator of Co-60, I-125, Ru-106, Ir-192, etc. These methods are shown to be very efficient but highly cost. The objective of this work is propose a detailed simulator modelling for eye characterization. Additionally, this study can contribute to design and build a new applicator in order to reduce the cost and to allow more patients to be treated

  8. Human secretory phospholipase A(2), group IB in normal eyes and in eye diseases

    DEFF Research Database (Denmark)

    Kolko, Miriam; Prause, Jan U; Bazan, Nicolas G

    2007-01-01

    , retinitis pigmentosa and glaucoma were evaluated. RESULTS: Expression of hGIB was found in various cells of the eye. The most abundant expression was found in retinal pigment epithelium (RPE) cells, the inner photoreceptor segments, ganglion cells and the corneal endothelium. We explored diseases involving...

  9. A scalable and deformable stylized model of the adult human eye for radiation dose assessment

    Science.gov (United States)

    El Basha, Daniel; Furuta, Takuya; Iyer, Siva S. R.; Bolch, Wesley E.

    2018-05-01

    With recent changes in the recommended annual limit on eye lens exposures to ionizing radiation, there is considerable interest in predictive computational dosimetry models of the human eye and its various ocular structures including the crystalline lens, ciliary body, cornea, retina, optic nerve, and central retinal artery. Computational eye models to date have been constructed as stylized models, high-resolution voxel models, and polygon mesh models. Their common feature, however, is that they are typically constructed of nominal size and of a roughly spherical shape associated with the emmetropic eye. In this study, we present a geometric eye model that is both scalable (allowing for changes in eye size) and deformable (allowing for changes in eye shape), and that is suitable for use in radiation transport studies of ocular exposures and radiation treatments of eye disease. The model allows continuous and variable changes in eye size (axial lengths from 20 to 26 mm) and eye shape (diopters from  ‑12 to  +6). As an explanatory example of its use, five models (emmetropic eyes of small, average, and large size, as well as average size eyes of  ‑12D and  +6D) were constructed and subjected to normally incident beams of monoenergetic electrons and photons, with resultant energy-dependent dose coefficients presented for both anterior and posterior eye structures. Electron dose coefficients were found to vary with changes to both eye size and shape for the posterior eye structures, while their values for the crystalline lens were found to be sensitive to changes in only eye size. No dependence upon eye size or eye shape was found for photon dose coefficients at energies below 2 MeV. Future applications of the model can include more extensive tabulations of dose coefficients to all ocular structures (not only the lens) as a function of eye size and shape, as well as the assessment of x-ray therapies for ocular disease for patients with non

  10. IL-23 and T(H)17-mediated inflammation in human allergic contact dermatitis

    DEFF Research Database (Denmark)

    Larsen, Jeppe Madura; Bonefeld, Charlotte Menné; Poulsen, Steen Seier

    2009-01-01

    . OBJECTIVE: To investigate T(H)17-mediated inflammation in human beings with allergic contact dermatitis; in particular, the innate response of keratinocytes to contact allergen, the induction of allergen-specific T(H)17 cells, and the presence of T(H)17-related effector cells in inflamed skin. METHODS....... CONCLUSION: Our results demonstrate the involvement of T(H)17-mediated immunopathology in human allergic contact dermatitis, including both innate and adaptive immune responses to contact allergens....

  11. Mycobacterium tuberculosis Invasion of the Human Lung: First Contact

    Directory of Open Access Journals (Sweden)

    Jeroen Maertzdorf

    2018-06-01

    Full Text Available Early immune responses to Mycobacterium tuberculosis (Mtb invasion of the human lung play a decisive role in the outcome of infection, leading to either rapid clearance of the pathogen or stable infection. Despite their critical impact on health and disease, these early host–pathogen interactions at the primary site of infection are still poorly understood. In vitro studies cannot fully reflect the complexity of the lung architecture and its impact on host–pathogen interactions, while animal models have their own limitations. In this study, we have investigated the initial responses in human lung tissue explants to Mtb infection, focusing primarily on gene expression patterns in different tissue-resident cell types. As first cell types confronted with pathogens invading the lung, alveolar macrophages, and epithelial cells displayed rapid proinflammatory chemokine and cytokine responses to Mtb infection. Other tissue-resident innate cells like gamma/delta T cells, mucosal associated invariant T cells, and natural killer cells showed partially similar but weaker responses, with a high degree of variability across different donors. Finally, we investigated the responses of tissue-resident innate lymphoid cells to the inflammatory milieu induced by Mtb infection. Our infection model provides a unique approach toward host–pathogen interactions at the natural port of Mtb entry and site of its implantation, i.e., the human lung. Our data provide a first detailed insight into the early responses of different relevant pulmonary cells in the alveolar microenvironment to contact with Mtb. These results can form the basis for the identification of host markers that orchestrate early host defense and provide resistance or susceptibility to stable Mtb infection.

  12. The applicability of correction factor for corneal thickness on non-contact tonometer measured intraocular pressure in LASIK treated eyes.

    Science.gov (United States)

    Jethani, Jitendra; Dave, Paaraj; Jethani, Monica; Desai, Yogesh; Patel, Purvi

    2016-01-01

    To determine the applicability of central corneal thickness (CCT) based correction factor for non-contact tonometer (NCT) measured intraocular pressure (IOP) readings. A prospective, non-randomized study involved 346 eyes of 173 consecutive patients with age ⩾21 years undergoing laser-assisted in situ keratomileusis (LASIK) for myopia and/or myopic astigmatism. The CCT and IOP were measured before and after the LASIK procedure. The IOP pre and post-LASIK was compared after applying the correction factor for CCT. Patients not completing the 3 month postoperative follow-up were excluded. The median spherical equivalent before undergoing LASIK was -4.25D (inter-quartile range, -3.25D). The mean preoperative CCT was 536.82 ± 33.71 μm which reduced to 477.55 ± 39.3 μm (p < 0.01) post-LASIK. The mean IOP reduced from a preoperative value of 14.6 ± 2.32 mmHg to 10.64 ± 2.45 mmHg postoperatively (p < 0.01). On applying correction for the corneal thickness, the pre and postoperative IOP was 15.14 ± 2.8 mmHg and 15.37 ± 2.65 mmHg (p = 0.06) respectively with a strong positive correlation (r = 0.7, p < 0.01). Three hundred eyes (86.7%) had an absolute difference in IOP of less than 3.0 mmHg post-CCT correction which is within the retest variability of NCT. Only 46 eyes (13.3%) had an absolute difference of more than 3.0 mmHg. The modified Ehler's correction algorithm used in this study can be effectively applied in the normal IOP range in a majority of patients.

  13. Characteristics of corneal biomechanical responses detected by a non-contact scheimpflug-based tonometer in eyes with glaucoma.

    Science.gov (United States)

    Jung, Younhea; Park, Hae-Young L; Yang, Hee Jung; Park, Chan Kee

    2017-11-01

    To determine the corneal biomechanical properties in eyes with glaucoma using a non-contact Scheimpflug-based tonometer. Corneal biomechanical responses were examined using a non-contact Scheimpflug-based tonometer. The tonometer parameters of the normal control group (n = 75) were compared with those of the glaucoma group (n = 136), including an analysis of glaucoma subgroups categorized by visual field loss. After adjusting for potential confounding factors, including the intraocular pressure (IOP), central corneal thickness (CCT), age and axial length, the deformation amplitude was smaller in the glaucoma group (1.09 ± 0.02 mm) than in the normal control group (1.12 ± 0.02 mm; p value = 0.031). The deformation amplitude and the deflection amplitude of the severe glaucoma group (1.12 ± 0.02 mm and 0.92 ± 0.01 mm) were significantly greater than that of the early glaucoma group (1.07 ± 0.01   mm and 0.88 ± 0.11 mm, p = 0.006 and p = 0.031), whereas that of the moderate glaucoma group (1.09 ± 0.02 mm and 0.90 ± 0.02 mm) was greater than that of the early glaucoma group, but this difference was not statistically significant. The deformation amplitude showed a negative correlation with the CCT in the normal control group (r = -0.235), with a weaker negative relationship observed in the early glaucoma group (r = -0.099). However, in the moderate and severe glaucoma groups, the deformation amplitude showed a positive relationship with the CCT, showing an inverse relationship. The duration and number of antiglaucomatous eyedrops used had negative correlations with the CCT in eyes with moderate and severe glaucoma. Overall, the glaucoma group showed significantly less deformable corneas than did the normal controls, even after adjusting for the IOP, CCT, age and axial length. However, there were also differences according to the severity of glaucoma, where the corneal deformation amplitude was greater in the severe glaucoma

  14. Dating the time of birth: A radiocarbon calibration curve for human eye-lens crystallines

    DEFF Research Database (Denmark)

    Kjeldsen, Henrik; Heinemeier, Jan; Heegaard, Steffen

    2010-01-01

    Radiocarbon bomb-pulse dating has been used to measure the formation age of human eye-lens crystallines. Lens crystallines are special proteins in the eye-lens that consist of virtually inert tissue. The experimental data show that the radiocarbon ages to a large extent reflect the time of birth...

  15. Computational Model-Based Prediction of Human Episodic Memory Performance Based on Eye Movements

    Science.gov (United States)

    Sato, Naoyuki; Yamaguchi, Yoko

    Subjects' episodic memory performance is not simply reflected by eye movements. We use a ‘theta phase coding’ model of the hippocampus to predict subjects' memory performance from their eye movements. Results demonstrate the ability of the model to predict subjects' memory performance. These studies provide a novel approach to computational modeling in the human-machine interface.

  16. High-speed adaptive optics line scan confocal retinal imaging for human eye.

    Science.gov (United States)

    Lu, Jing; Gu, Boyu; Wang, Xiaolin; Zhang, Yuhua

    2017-01-01

    Continuous and rapid eye movement causes significant intraframe distortion in adaptive optics high resolution retinal imaging. To minimize this artifact, we developed a high speed adaptive optics line scan confocal retinal imaging system. A high speed line camera was employed to acquire retinal image and custom adaptive optics was developed to compensate the wave aberration of the human eye's optics. The spatial resolution and signal to noise ratio were assessed in model eye and in living human eye. The improvement of imaging fidelity was estimated by reduction of intra-frame distortion of retinal images acquired in the living human eyes with frame rates at 30 frames/second (FPS), 100 FPS, and 200 FPS. The device produced retinal image with cellular level resolution at 200 FPS with a digitization of 512×512 pixels/frame in the living human eye. Cone photoreceptors in the central fovea and rod photoreceptors near the fovea were resolved in three human subjects in normal chorioretinal health. Compared with retinal images acquired at 30 FPS, the intra-frame distortion in images taken at 200 FPS was reduced by 50.9% to 79.7%. We demonstrated the feasibility of acquiring high resolution retinal images in the living human eye at a speed that minimizes retinal motion artifact. This device may facilitate research involving subjects with nystagmus or unsteady fixation due to central vision loss.

  17. Imaging shear stress distribution and evaluating the stress concentration factor of the human eye

    Science.gov (United States)

    Joseph Antony, S.

    2015-03-01

    Healthy eyes are vital for a better quality of human life. Historically, for man-made materials, scientists and engineers use stress concentration factors to characterise the effects of structural non-homogeneities on their mechanical strength. However, such information is scarce for the human eye. Here we present the shear stress distribution profiles of a healthy human cornea surface in vivo using photo-stress analysis tomography, which is a non-intrusive and non-X-ray based method. The corneal birefringent retardation measured here is comparable to that of previous studies. Using this, we derive eye stress concentration factors and the directional alignment of major principal stress on the surface of the cornea. Similar to thermometers being used for monitoring the general health in humans, this report provides a foundation to characterise the shear stress carrying capacity of the cornea, and a potential bench mark for validating theoretical modelling of stresses in the human eye in future.

  18. Vergence-mediated changes in the axis of eye rotation during the human vestibulo-ocular reflex can occur independent of eye position.

    Science.gov (United States)

    Migliaccio, Americo A; Cremer, Phillip D; Aw, Swee T; Halmagyi, G Michael; Curthoys, Ian S; Minor, Lloyd B; Todd, Michael J

    2003-07-01

    The aim of this study was to determine whether vergence-mediated changes in the axis of eye rotation in the human vestibulo-ocular reflex (VOR) would obey Listing's Law (normally associated with saccadic eye movements) independent of the initial eye position. We devised a paradigm for disassociating the saccadic velocity axis from eye position by presenting near and far targets that were centered with respect to one eye. We measured binocular 3-dimensional eye movements using search coils in ten normal subjects and 3-dimensional linear head acceleration using Optotrak in seven normal subjects. The stimuli consisted of passive, unpredictable, pitch head rotations with peak acceleration of approximately 2000 degrees /s(2 )and amplitude of approximately 20 degrees. During the pitch head rotation, each subject fixated straight ahead with one eye, whereas the other eye was adducted 4 degrees during far viewing (94 cm) and 25 degrees during near viewing (15 cm). Our data showed expected compensatory pitch rotations in both eyes, and a vergence-mediated horizontal rotation only in the adducting eye. In addition, during near viewing we observed torsional eye rotations not only in the adducting eye but also in the eye looking straight ahead. In the straight-ahead eye, the change in torsional eye velocity between near and far viewing, which began approximately 40 ms after the start of head rotation, was 10+/-6 degrees /s (mean +/- SD). This change in torsional eye velocity resulted in a 2.4+/-1.5 degrees axis tilt toward Listing's plane in that eye. In the adducting eye, the change in torsional eye velocity between near and far viewing was 16+/-6 degrees /s (mean +/- SD) and resulted in a 4.1+/-1.4 degrees axis tilt. The torsional eye velocities were conjugate and both eyes partially obeyed Listing's Law. The axis of eye rotation tilted in the direction of the line of sight by approximately one-third of the angle between the line of sight and a line orthogonal to Listing

  19. EyeFrame: Real-time memory aid improves human multitasking via domain-general eye tracking procedures

    Directory of Open Access Journals (Sweden)

    P. eTaylor

    2015-09-01

    Full Text Available OBJECTIVE: We developed an extensively general closed-loop system to improve human interaction in various multitasking scenarios, with semi-autonomous agents, processes, and robots. BACKGROUND: Much technology is converging toward semi-independent processes with intermittent human supervision distributed over multiple computerized agents. Human operators multitask notoriously poorly, in part due to cognitive load and limited working memory. To multitask optimally, users must remember task order, e.g., the most neglected task, since longer times not monitoring an element indicates greater probability of need for user input. The secondary task of monitoring attention history over multiple spatial tasks requires similar cognitive resources as primary tasks themselves. Humans can not reliably make more than ~2 decisions/s. METHODS: Participants managed a range of 4-10 semi-autonomous agents performing rescue tasks. To optimize monitoring and controlling multiple agents, we created an automated short term memory aid, providing visual cues from users' gaze history. Cues indicated when and where to look next, and were derived from an inverse of eye fixation recency. RESULTS: Contingent eye tracking algorithms drastically improved operator performance, increasing multitasking capacity. The gaze aid reduced biases, and reduced cognitive load, measured by smaller pupil dilation. CONCLUSIONS: Our eye aid likely helped by delegating short-term memory to the computer, and by reducing decision making load. Past studies used eye position for gaze-aware control and interactive updating of displays in application-specific scenarios, but ours is the first to successfully implement domain-general algorithms. Procedures should generalize well to: process control, factory operations, robot control, surveillance, aviation, air traffic control, driving, military, mobile search and rescue, and many tasks where probability of utility is predicted by duration since last

  20. Dual Logic and Cerebral Coordinates for Reciprocal Interaction in Eye Contact

    Science.gov (United States)

    Lee, Ray F.

    2015-01-01

    In order to scientifically study the human brain’s response to face-to-face social interaction, the scientific method itself needs to be reconsidered so that both quantitative observation and symbolic reasoning can be adapted to the situation where the observer is also observed. In light of the recent development of dyadic fMRI which can directly observe dyadic brain interacting in one MRI scanner, this paper aims to establish a new form of logic, dual logic, which provides a theoretical platform for deductive reasoning in a complementary dual system with emergence mechanism. Applying the dual logic in the dfMRI experimental design and data analysis, the exogenous and endogenous dual systems in the BOLD responses can be identified; the non-reciprocal responses in the dual system can be suppressed; a cerebral coordinate for reciprocal interaction can be generated. Elucidated by dual logic deductions, the cerebral coordinate for reciprocal interaction suggests: the exogenous and endogenous systems consist of the empathy network and the mentalization network respectively; the default-mode network emerges from the resting state to activation in the endogenous system during reciprocal interaction; the cingulate plays an essential role in the emergence from the exogenous system to the endogenous system. Overall, the dual logic deductions are supported by the dfMRI experimental results and are consistent with current literature. Both the theoretical framework and experimental method set the stage to formally apply the scientific method in studying complex social interaction. PMID:25885446

  1. Dual logic and cerebral coordinates for reciprocal interaction in eye contact.

    Directory of Open Access Journals (Sweden)

    Ray F Lee

    Full Text Available In order to scientifically study the human brain's response to face-to-face social interaction, the scientific method itself needs to be reconsidered so that both quantitative observation and symbolic reasoning can be adapted to the situation where the observer is also observed. In light of the recent development of dyadic fMRI which can directly observe dyadic brain interacting in one MRI scanner, this paper aims to establish a new form of logic, dual logic, which provides a theoretical platform for deductive reasoning in a complementary dual system with emergence mechanism. Applying the dual logic in the dfMRI experimental design and data analysis, the exogenous and endogenous dual systems in the BOLD responses can be identified; the non-reciprocal responses in the dual system can be suppressed; a cerebral coordinate for reciprocal interaction can be generated. Elucidated by dual logic deductions, the cerebral coordinate for reciprocal interaction suggests: the exogenous and endogenous systems consist of the empathy network and the mentalization network respectively; the default-mode network emerges from the resting state to activation in the endogenous system during reciprocal interaction; the cingulate plays an essential role in the emergence from the exogenous system to the endogenous system. Overall, the dual logic deductions are supported by the dfMRI experimental results and are consistent with current literature. Both the theoretical framework and experimental method set the stage to formally apply the scientific method in studying complex social interaction.

  2. Relationship between eye dominance and pattern electroretinograms in normal human subjects.

    Science.gov (United States)

    Kamis, Umit; Gunduz, Kemal; Okudan, Nilsel; Gokbel, Hakki; Bodur, Sait; Tan, Uner

    2005-02-01

    The authors conducted a study in 100 non-smoker healthy normal human subjects to find a relationship between eye dominance and macular function as tested by using transient stimulus and electroretinography. Eye preference procedure was carried out using two reference points and pattern electroretinograms (PERGs) were recorded using black and white checks, each check subtending 23'. Trace averager was retriggered every 300 milliseconds (ms) with data collection time of 150 ms. The difference in PERG P50 amplitudes between right and left eyes was analyzed using Student's t test. There was no significant difference in PERG P50 amplitudes between the right and left eye dominant subjects as well as no significant differences between the right and left eyes in right eye dominants and left eye dominants, but in the left-eye dominant group the left eye PERG P50 amplitudes were significantly higher in females than males. Although pattern-reversal visual evoked potentials of healthy subjects provide electrophysiological evidence of lateralization in the nervous system, sensory eye dominance seems to have no correlation with macular function.

  3. Proton absorbed dose distribution in human eye simulated by SRNA-2KG code

    International Nuclear Information System (INIS)

    Ilic, R. D.; Pavlovic, R.

    2004-01-01

    The model of Monte Carlo SRNA code is described together with some numerical experiments to show feasibility of this code to be used in proton therapy, especially for tree dimensional proton absorption dose calculation in human eye. (author) [sr

  4. Who is the Usual Suspect? Evidence of a Selection Bias Toward Faces That Make Direct Eye Contact in a Lineup Task

    Science.gov (United States)

    van Golde, Celine; Verstraten, Frans A. J.

    2017-01-01

    The speed and ease with which we recognize the faces of our friends and family members belies the difficulty we have recognizing less familiar individuals. Nonetheless, overconfidence in our ability to recognize faces has carried over into various aspects of our legal system; for instance, eyewitness identification serves a critical role in criminal proceedings. For this reason, understanding the perceptual and psychological processes that underlie false identification is of the utmost importance. Gaze direction is a salient social signal and direct eye contact, in particular, is thought to capture attention. Here, we tested the hypothesis that differences in gaze direction may influence difficult decisions in a lineup context. In a series of experiments, we show that when a group of faces differed in their gaze direction, the faces that were making eye contact with the participants were more likely to be misidentified. Interestingly, this bias disappeared when the faces are presented with their eyes closed. These findings open a critical conversation between social neuroscience and forensic psychology, and imply that direct eye contact may (wrongly) increase the perceived familiarity of a face. PMID:28203355

  5. Effect of direct eye contact in PTSD related to interpersonal trauma: an fMRI study of activation of an innate alarm system.

    Science.gov (United States)

    Steuwe, Carolin; Daniels, Judith K; Frewen, Paul A; Densmore, Maria; Pannasch, Sebastian; Beblo, Thomas; Reiss, Jeffrey; Lanius, Ruth A

    2014-01-01

    In healthy individuals, direct eye contact initially leads to activation of a fast subcortical pathway, which then modulates a cortical route eliciting social cognitive processes. The aim of this study was to gain insight into the neurobiological effects of direct eye-to-eye contact using a virtual reality paradigm in individuals with posttraumatic stress disorder (PTSD) related to prolonged childhood abuse. We examined 16 healthy comparison subjects and 16 patients with a primary diagnosis of PTSD using a virtual reality functional magnetic resonance imaging paradigm involving direct vs averted gaze (happy, sad, neutral) as developed by Schrammel et al. in 2009. Irrespective of the displayed emotion, controls exhibited an increased blood oxygenation level-dependent response during direct vs averted gaze within the dorsomedial prefrontal cortex, left temporoparietal junction and right temporal pole. Under the same conditions, individuals with PTSD showed increased activation within the superior colliculus (SC)/periaqueductal gray (PAG) and locus coeruleus. Our findings suggest that healthy controls react to the exposure of direct gaze with an activation of a cortical route that enhances evaluative 'top-down' processes underlying social interactions. In individuals with PTSD, however, direct gaze leads to sustained activation of a subcortical route of eye-contact processing, an innate alarm system involving the SC and the underlying circuits of the PAG.

  6. Who is the Usual Suspect? Evidence of a Selection Bias Toward Faces That Make Direct Eye Contact in a Lineup Task

    Directory of Open Access Journals (Sweden)

    Jessica Taubert

    2017-02-01

    Full Text Available The speed and ease with which we recognize the faces of our friends and family members belies the difficulty we have recognizing less familiar individuals. Nonetheless, overconfidence in our ability to recognize faces has carried over into various aspects of our legal system; for instance, eyewitness identification serves a critical role in criminal proceedings. For this reason, understanding the perceptual and psychological processes that underlie false identification is of the utmost importance. Gaze direction is a salient social signal and direct eye contact, in particular, is thought to capture attention. Here, we tested the hypothesis that differences in gaze direction may influence difficult decisions in a lineup context. In a series of experiments, we show that when a group of faces differed in their gaze direction, the faces that were making eye contact with the participants were more likely to be misidentified. Interestingly, this bias disappeared when the faces are presented with their eyes closed. These findings open a critical conversation between social neuroscience and forensic psychology, and imply that direct eye contact may (wrongly increase the perceived familiarity of a face.

  7. Retinal images in the human eye with implanted intraocular lens

    Science.gov (United States)

    Zając, Marek; Siedlecki, Damian; Nowak, Jerzy

    2007-04-01

    A typical proceeding in cataract is based on the removal of opaque crystalline lens and inserting in its place the artificial intraocular lens (IOL). The quality of retinal image after such procedure depends, among others, on the parameters of the IOL, so the design of the implanted lens is of great importance. An appropriate choice of the IOL material, especially in relation to its biocompatibility, is often considered. However the parameter, which is often omitted during the IOL design is its chromatic aberration. In particular lack of its adequacy to the chromatic aberration of a crystalline lens may cause problems. In order to fit better chromatic aberration of the eye with implanted IOL to that of the healthy eye we propose a hybrid - refractive-diffractive IOL. It can be designed in such way that the total longitudinal chromatic aberration of an eye with implanted IOL equals the total longitudinal chromatic aberration of a healthy eye. In this study we compare the retinal image quality calculated numerically on the basis of the well known Liou-Brennan eye model with typical IOL implanted with that obtained if the IOL is done as hybrid (refractive-diffractive) design.

  8. Pharmacokinetics of bevacizumab after topical and intravitreal administration in human eyes

    OpenAIRE

    Moisseiev, Elad; Waisbourd, Michael; Ben-Artsi, Elad; Levinger, Eliya; Barak, Adiel; Daniels, Tad; Csaky, Karl; Loewenstein, Anat; Barequet, Irina S.

    2013-01-01

    Background Topical bevacizumab is a potential treatment modality for corneal neovascularization, and several recent studies have demonstrated its efficacy. No previous study of the pharmacokinetics of topical bevacizumab has been performed in human eyes. The purpose of this study is to investigate the pharmacokinetics of topical administration of bevacizumab in human eyes, and also to compare the pharmacokinetics of intravitreal bevacizumab injections with previously reported data. Methods Tw...

  9. The Optical Design of the Human Eye: a Critical Review

    Directory of Open Access Journals (Sweden)

    Rafael Navarro

    2009-01-01

    Full Text Available Cornea, lens and eye models are analyzed and compared to experimental findings to assess properties and eventually unveil optical design principles involved in the structure and function of the optical system of the eye. Models and data often show good match but also some paradoxes. The optical design seems to correspond to a wide angle lens. Compared to conventional optical systems, the eye presents a poor optical quality on axis, but a relatively good quality off-axis, thus yielding higher homogeneity for a wide visual field. This seems the result of an intriguing combination of the symmetry design principle with a total lack of rotational symmetry, decentrations and misalignments of the optical surfaces.

  10. A computational model of blast loading on the human eye.

    Science.gov (United States)

    Bhardwaj, Rajneesh; Ziegler, Kimberly; Seo, Jung Hee; Ramesh, K T; Nguyen, Thao D

    2014-01-01

    Ocular injuries from blast have increased in recent wars, but the injury mechanism associated with the primary blast wave is unknown. We employ a three-dimensional fluid-structure interaction computational model to understand the stresses and deformations incurred by the globe due to blast overpressure. Our numerical results demonstrate that the blast wave reflections off the facial features around the eye increase the pressure loading on and around the eye. The blast wave produces asymmetric loading on the eye, which causes globe distortion. The deformation response of the globe under blast loading was evaluated, and regions of high stresses and strains inside the globe were identified. Our numerical results show that the blast loading results in globe distortion and large deviatoric stresses in the sclera. These large deviatoric stresses may be indicator for the risk of interfacial failure between the tissues of the sclera and the orbit.

  11. A new human eye model for ophthalmic brachytherapy dosimetry

    International Nuclear Information System (INIS)

    Yoriyaz, H.; Sanchez, A.; Dos Santos, A.

    2005-01-01

    The present work proposes a new mathematical eye model for ophthalmic brachytherapy dosimetry. This new model includes detailed description of internal structures that were not treated in previous works, allowing dose determination in different regions of the eye for a more adequate clinical analysis. Dose calculations were determined with the MCNP-4C Monte Carlo particle transport code running n parallel environment using PVM. The Amersham CKA4 ophthalmic applicator has been chosen and the depth dose distribution has been determined and compared to those provide by the manufacturer. The results have shown excellent agreement. Besides, absorbed dose values due to both 125 I seeds and 60 Co plaques were obtained for each one of the different structures which compose the eye model and can give relevant information in eventual clinical analyses. (authors)

  12. Dating the time of birth: A radiocarbon calibration curve for human eye-lens crystallines

    Energy Technology Data Exchange (ETDEWEB)

    Kjeldsen, Henrik, E-mail: kjeldsen@phys.au.d [AMS 14C Dating Centre, Department of Physics and Astronomy, University of Aarhus, Aarhus (Denmark); Heinemeier, Jan [AMS 14C Dating Centre, Department of Physics and Astronomy, University of Aarhus, Aarhus (Denmark); Heegaard, Steffen [Eye Pathology Section, Department of Neuroscience and Pharmacology, University of Copenhagen, Copenhagen (Denmark); Jacobsen, Christina; Lynnerup, Niels [Department of Forensic Medicine, University of Copenhagen, Copenhagen (Denmark)

    2010-04-15

    Radiocarbon bomb-pulse dating has been used to measure the formation age of human eye-lens crystallines. Lens crystallines are special proteins in the eye-lens that consist of virtually inert tissue. The experimental data show that the radiocarbon ages to a large extent reflect the time of birth, in accordance with expectations. Moreover, it has been possible to develop an age model for the formation of the eye-lens crystallines. From this model a radiocarbon calibration curve for lens crystallines has been calculated. As a consequence, the time of birth of humans can be determined with an accuracy of a few years by radiocarbon dating.

  13. Dating the time of birth: A radiocarbon calibration curve for human eye-lens crystallines

    International Nuclear Information System (INIS)

    Kjeldsen, Henrik; Heinemeier, Jan; Heegaard, Steffen; Jacobsen, Christina; Lynnerup, Niels

    2010-01-01

    Radiocarbon bomb-pulse dating has been used to measure the formation age of human eye-lens crystallines. Lens crystallines are special proteins in the eye-lens that consist of virtually inert tissue. The experimental data show that the radiocarbon ages to a large extent reflect the time of birth, in accordance with expectations. Moreover, it has been possible to develop an age model for the formation of the eye-lens crystallines. From this model a radiocarbon calibration curve for lens crystallines has been calculated. As a consequence, the time of birth of humans can be determined with an accuracy of a few years by radiocarbon dating.

  14. Measuring Human Performance in Simulated Nuclear Power Plant Control Rooms Using Eye Tracking

    Energy Technology Data Exchange (ETDEWEB)

    Kovesdi, Casey Robert [Idaho National Lab. (INL), Idaho Falls, ID (United States); Rice, Brandon Charles [Idaho National Lab. (INL), Idaho Falls, ID (United States); Bower, Gordon Ross [Idaho National Lab. (INL), Idaho Falls, ID (United States); Spielman, Zachary Alexander [Idaho National Lab. (INL), Idaho Falls, ID (United States); Hill, Rachael Ann [Idaho National Lab. (INL), Idaho Falls, ID (United States); LeBlanc, Katya Lee [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-11-01

    Control room modernization will be an important part of life extension for the existing light water reactor fleet. As part of modernization efforts, personnel will need to gain a full understanding of how control room technologies affect performance of human operators. Recent advances in technology enables the use of eye tracking technology to continuously measure an operator’s eye movement, which correlates with a variety of human performance constructs such as situation awareness and workload. This report describes eye tracking metrics in the context of how they will be used in nuclear power plant control room simulator studies.

  15. Measuring Human Performance in Simulated Nuclear Power Plant Control Rooms Using Eye Tracking

    International Nuclear Information System (INIS)

    Kovesdi, Casey Robert; Rice, Brandon Charles; Bower, Gordon Ross; Spielman, Zachary Alexander; Hill, Rachael Ann; LeBlanc, Katya Lee

    2015-01-01

    Control room modernization will be an important part of life extension for the existing light water reactor fleet. As part of modernization efforts, personnel will need to gain a full understanding of how control room technologies affect performance of human operators. Recent advances in technology enables the use of eye tracking technology to continuously measure an operator's eye movement, which correlates with a variety of human performance constructs such as situation awareness and workload. This report describes eye tracking metrics in the context of how they will be used in nuclear power plant control room simulator studies.

  16. Dynamical models of the human eye and strabismus

    International Nuclear Information System (INIS)

    Pascolo, P.; Carniel, R.; Grimaz, S.

    2009-01-01

    In this work, the applicability of a recently published dynamical model of the eye to the case of strabismus is investigated. Although the basic scheme of the original model remains valid, the simulation of the pathological dynamics requires a more suitable coverage of the space of the physiological rotations of the eye. This requisite is reached by developing the original model and by taking into account the contributions of connective tissues that were originally neglected. Possible wider fields of application of the model are then discussed.

  17. Human Commercial Models' Eye Colour Shows Negative Frequency-Dependent Selection.

    Directory of Open Access Journals (Sweden)

    Isabela Rodrigues Nogueira Forti

    Full Text Available In this study we investigated the eye colour of human commercial models registered in the UK (400 female and 400 male and Brazil (400 female and 400 male to test the hypothesis that model eye colour frequency was the result of negative frequency-dependent selection. The eye colours of the models were classified as: blue, brown or intermediate. Chi-square analyses of data for countries separated by sex showed that in the United Kingdom brown eyes and intermediate colours were significantly more frequent than expected in comparison to the general United Kingdom population (P<0.001. In Brazil, the most frequent eye colour brown was significantly less frequent than expected in comparison to the general Brazilian population. These results support the hypothesis that model eye colour is the result of negative frequency-dependent selection. This could be the result of people using eye colour as a marker of genetic diversity and finding rarer eye colours more attractive because of the potential advantage more genetically diverse offspring that could result from such a choice. Eye colour may be important because in comparison to many other physical traits (e.g., hair colour it is hard to modify, hide or disguise, and it is highly polymorphic.

  18. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye Health A-Z Symptoms Glasses & Contacts Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye ... Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ...

  19. Oxygen Tension in the Aqueous Humor of Human Eyes under Different Oxygenation Conditions

    Directory of Open Access Journals (Sweden)

    Farideh Sharifipour

    2013-01-01

    Full Text Available Purpose: To measure oxygen tension in the aqueous humor of human eyes under different oxygenation conditions. Methods: This prospective comparative interventional case series consisted of two parts. In the first part, 120 consecutive patients scheduled for cataract surgery were randomized into group I (control group in which surgery was performed under local anesthesia inhaling 21% oxygen; group II in whom general anesthesia using 50% oxygen was employed; and group III receiving general anesthesia with 100% oxygen. After aspirating 0.2 ml aqueous humor under sterile conditions, the aqueous sample and a simultaneously drawn arterial blood sample were immediately analyzed using a blood gas analyzer. In part II the same procedures were performed in 10 patients after fitting a contact lens and patching the eye for 20 minutes (group IV and in 10 patients after transcorneal delivery of oxygen at a flow rate of 5 L/min (group V. Results: Mean aqueous PO2 in groups I, II and III was 112.3±6.2, 141.1±20.4, and 170.1±27 mmHg, respectively (P values <0.001 and mean arterial PO2 was 85.7±7.9, 184.6±46, and 379.1±75.9 mmHg, respectively (P values <0.001. Aqueous PO2 was 77.2±9.2 mmHg in group IV and 152.3±10.9 mmHg in group V (P values <0.001. There was a significant correlation between aqueous and blood PO2 (r=0.537, P<0.001. The contribution of atmospheric oxygen to aqueous PO2 was 23.7%. Conclusion: Aqueous oxygen tension is mostly dependent on the systemic circulation and in part on the atmosphere. Increasing inspiratory oxygen and transcorneal oxygen delivery both increase aqueous PO2 levels.

  20. Contact-Free Heartbeat Signal for Human Identification and Forensics

    DEFF Research Database (Denmark)

    Nasrollahi, Kamal; Haque, Mohammad Ahsanul; Irani, Ramin

    2017-01-01

    The heartbeat signal, which is one of the physiological signals, is of great importance in many real-world applications, for example, in patient monitoring and biometric recognition. The traditional methods for measuring such this signal use contact-based sensors that need to be installed...... been developed for contact-free extraction of the heartbeat signal. We have recently used the contact-free measured heartbeat signal, for bio- metric recognition, and have obtained promising results, indicating the importance of these signals for biometrics recognition and also for forensics...

  1. Eye Detection and Tracking for Intelligent Human Computer Interaction

    National Research Council Canada - National Science Library

    Yin, Lijun

    2006-01-01

    .... In this project, Dr. Lijun Yin has developed a new algorithm for detecting and tracking eyes under an unconstrained environment using a single ordinary camera or webcam. The new algorithm is advantageous in that it works in a non-intrusive way based on a socalled Topographic Context approach.

  2. Objective measurement of postocclusion surge during phacoemulsification in human eye-bank eyes.

    Science.gov (United States)

    Georgescu, Dan; Payne, Marielle; Olson, Randall J

    2007-03-01

    To objectively compare the postocclusion vacuum surge among different phacoemulsification machines and devices. Experimental study. Infiniti, Legacy, Millennium, and Sovereign were tested in an eye-bank eye. All the machines were tested with 20-gauge non-ABS tips, 430 mm Hg vacuum pressure, 24 ml/minute aspiration rate, peristaltic pump, and 75 cm bottle height. In addition, Infiniti and Legacy were also tested with 20-gauge bypass tips (ABS), 125 cm bottle height, and 40 ml/minute flow rate. We also tested 19-gauge tips with Infiniti and Sovereign and the venturi pump for Millennium. Significant differences were found between all the machines tested with Millennium peristaltic generating the least and Millennium Venturi the most surge. ABS tips significantly decreased the surge for Legacy but not for Infiniti. Cruise Control (CC) had a significant effect on Sovereign but not on Millennium. Increasing the bottle height decreased surge while increasing the flow increased surge for both Infiniti and Legacy. The 19-gauge tips increased surge for both Infiniti and Sovereign. Surge varied over a range of 40 microm to more than 2 mm. ABS and CC decrease surge, especially when the machine is not functioning near the limits of surge prevention. Certain parameters, such as a 19-gauge tip and high flow, dramatically increased surge, whereas elevating the bottle ameliorates it. Understanding the impact of all these features will help in minimizing the problem.

  3. Image system analysis of human eye wave-front aberration on the basis of HSS

    Science.gov (United States)

    Xu, Ancheng

    2017-07-01

    Hartmann-Shack sensor (HSS) has been used in objective measurement of human eye wave-front aberration, but the research on the effects of sampling point size on the accuracy of the result has not been reported. In this paper, point spread function (PSF) of the whole system mathematical model was obtained via measuring the optical imaging system structure of human eye wave-front aberration measurement. The impact of Airy spot size on the accuracy of system was analyzed. Statistics study show that the geometry of Airy spot size of the ideal light source sent from eye retina formed on the surface of HSS is far smaller than the size of the HSS sample point image used in the experiment. Therefore, the effect of Airy spot on the precision of the system can be ignored. This study theoretically and experimentally justifies the reliability and accuracy of human eye wave-front aberration measurement based on HSS.

  4. Multiconjugate adaptive optics applied to an anatomically accurate human eye model.

    Science.gov (United States)

    Bedggood, P A; Ashman, R; Smith, G; Metha, A B

    2006-09-04

    Aberrations of both astronomical telescopes and the human eye can be successfully corrected with conventional adaptive optics. This produces diffraction-limited imagery over a limited field of view called the isoplanatic patch. A new technique, known as multiconjugate adaptive optics, has been developed recently in astronomy to increase the size of this patch. The key is to model atmospheric turbulence as several flat, discrete layers. A human eye, however, has several curved, aspheric surfaces and a gradient index lens, complicating the task of correcting aberrations over a wide field of view. Here we utilize a computer model to determine the degree to which this technology may be applied to generate high resolution, wide-field retinal images, and discuss the considerations necessary for optimal use with the eye. The Liou and Brennan schematic eye simulates the aspheric surfaces and gradient index lens of real human eyes. We show that the size of the isoplanatic patch of the human eye is significantly increased through multiconjugate adaptive optics.

  5. Multiconjugate adaptive optics applied to an anatomically accurate human eye model

    Science.gov (United States)

    Bedggood, P. A.; Ashman, R.; Smith, G.; Metha, A. B.

    2006-09-01

    Aberrations of both astronomical telescopes and the human eye can be successfully corrected with conventional adaptive optics. This produces diffraction-limited imagery over a limited field of view called the isoplanatic patch. A new technique, known as multiconjugate adaptive optics, has been developed recently in astronomy to increase the size of this patch. The key is to model atmospheric turbulence as several flat, discrete layers. A human eye, however, has several curved, aspheric surfaces and a gradient index lens, complicating the task of correcting aberrations over a wide field of view. Here we utilize a computer model to determine the degree to which this technology may be applied to generate high resolution, wide-field retinal images, and discuss the considerations necessary for optimal use with the eye. The Liou and Brennan schematic eye simulates the aspheric surfaces and gradient index lens of real human eyes. We show that the size of the isoplanatic patch of the human eye is significantly increased through multiconjugate adaptive optics.

  6. The Human Eye Position Control System in a Rehabilitation Setting

    Directory of Open Access Journals (Sweden)

    Yvonne Nolan

    2005-01-01

    Full Text Available Our work at Ireland’s National Rehabilitation Hospital involves designing communication systems for people suffering from profound physical disabilities. One such system uses the electro-oculogram, which is an (x,y system of voltages picked up by pairs of electrodes placed, respectively, above and below and on either side of the eyes. The eyeball has a dc polarisation between cornea and back, arising from the photoreceptor rods and cones in the retina. As the eye rotates, the varying voltages projected onto the electrodes drive a cursor over a mimic keyboard on a computer screen. Symbols are selected with a switching action derived, for example, from a blink. Experience in using this mode of communication has given us limited facilities to study the eye position control system. We present here a resulting new feedback model for rotation in either the vertical or the horizontal plane, which involves the eyeball controlled by an agonist-antagonist muscle pair, modelled by a single equivalent bidirectional muscle with torque falling off linearly with angular velocity. We have incorporated muscle spindles and have tuned them by pole assignment associated with an optimum stability criterion.

  7. A generalised porous medium approach to study thermo-fluid dynamics in human eyes.

    Science.gov (United States)

    Mauro, Alessandro; Massarotti, Nicola; Salahudeen, Mohamed; Romano, Mario R; Romano, Vito; Nithiarasu, Perumal

    2018-03-22

    The present work describes the application of the generalised porous medium model to study heat and fluid flow in healthy and glaucomatous eyes of different subject specimens, considering the presence of ocular cavities and porous tissues. The 2D computational model, implemented into the open-source software OpenFOAM, has been verified against benchmark data for mixed convection in domains partially filled with a porous medium. The verified model has been employed to simulate the thermo-fluid dynamic phenomena occurring in the anterior section of four patient-specific human eyes, considering the presence of anterior chamber (AC), trabecular meshwork (TM), Schlemm's canal (SC), and collector channels (CC). The computational domains of the eye are extracted from tomographic images. The dependence of TM porosity and permeability on intraocular pressure (IOP) has been analysed in detail, and the differences between healthy and glaucomatous eye conditions have been highlighted, proving that the different physiological conditions of patients have a significant influence on the thermo-fluid dynamic phenomena. The influence of different eye positions (supine and standing) on thermo-fluid dynamic variables has been also investigated: results are presented in terms of velocity, pressure, temperature, friction coefficient and local Nusselt number. The results clearly indicate that porosity and permeability of TM are two important parameters that affect eye pressure distribution. Graphical abstract Velocity contours and vectors for healthy eyes (top) and glaucomatous eyes (bottom) for standing position.

  8. Early visual evoked potentials are modulated by eye position in humans induced by whole body rotations

    Directory of Open Access Journals (Sweden)

    Petit Laurent

    2004-09-01

    Full Text Available Abstract Background To reach and grasp an object in space on the basis of its image cast on the retina requires different coordinate transformations that take into account gaze and limb positioning. Eye position in the orbit influences the image's conversion from retinotopic (eye-centered coordinates to an egocentric frame necessary for guiding action. Neuroimaging studies have revealed eye position-dependent activity in extrastriate visual, parietal and frontal areas that is along the visuo-motor pathway. At the earliest vision stage, the role of the primary visual area (V1 in this process remains unclear. We used an experimental design based on pattern-onset visual evoked potentials (VEP recordings to study the effect of eye position on V1 activity in humans. Results We showed that the amplitude of the initial C1 component of VEP, acknowledged to originate in V1, was modulated by the eye position. We also established that putative spontaneous small saccades related to eccentric fixation, as well as retinal disparity cannot explain the effects of changing C1 amplitude of VEP in the present study. Conclusions The present modulation of the early component of VEP suggests an eye position-dependent activity of the human primary visual area. Our findings also evidence that cortical processes combine information about the position of the stimulus on the retinae with information about the location of the eyes in their orbit as early as the stage of primary visual area.

  9. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not been properly fitted by an eye care professional, the lenses stuck to my eye like a ... prescription and proper fitting by an eye-care professional. Retailers that sell contacts without a prescription are ...

  10. 77 FR 14022 - Guidance for Industry: Testing for Salmonella Species in Human Foods and Direct-Human-Contact...

    Science.gov (United States)

    2012-03-08

    ...-contact animal foods, and the interpretation of test results, when the presence of Salmonella spp. in the... eggs) and direct-human-contact animal foods, and the interpretation of test results, when the presence... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-D-0091...

  11. Effects of intraocular lenses with different diopters on chromatic aberrations in human eye models

    OpenAIRE

    Song, Hui; Yuan, Xiaoyong; Tang, Xin

    2016-01-01

    Background In this study, the effects of intraocular lenses (IOLs) with different diopters (D) on chromatic aberration were investigated in human eye models, and the influences of the central thickness of IOLs on chromatic aberration were compared. Methods A Liou-Brennan-based IOL eye model was constructed using ZEMAX optical design software. Spherical IOLs with different diopters (AR40e, AMO Company, USA) were implanted; modulation transfer function (MTF) values at 3?mm of pupil diameter and...

  12. Contact Lens Risks

    Science.gov (United States)

    ... There is a risk of eye infection from bacteria in swimming pool water, hot tubs, lakes and the ocean Replace your contact lens storage case every 3 months or as directed by your eye care professional. Other Risks of Contact Lenses Other risks of contact lenses include pink eye ( ...

  13. Proper balance of omega-3 and omega-6 fatty acid supplements with topical cyclosporine attenuated contact lens-related dry eye syndrome.

    Science.gov (United States)

    Wang, Ling; Chen, Xi; Hao, Jingfang; Yang, Lu

    2016-12-01

    Essential fatty acids had been applied in the treatment of dry eye syndrome (DES), but the effects of different combinations of fatty acids have not been investigated. 360 long-term contact lens wearers were included in this double-blinded study. Omega-3 and omega-6 fatty acids were combined in different ratios and supplied to the participants that were randomly divided into six groups, and the effects of different essential fatty acids mixture on DES with or without topical cyclosporine were investigated. More than half of long-term contact lens wearers suffered from DES, which were found to be attenuated by oral supplement of properly balanced O3FA and O6FA fatty acid. The topical cyclosporine treatment considerably inhibited the production of cytokines compared to the cyclosporine negative groups, which further relieved DES. Proper balance of omega-3 and omega-6 fatty acid combination significantly alleviated contact lens-related DES.

  14. Goat′s eye integrated with a human cataractous lens: A training model for phacoemulsification

    Directory of Open Access Journals (Sweden)

    Sabyasachi Sengupta

    2015-01-01

    Full Text Available A relatively simple and inexpensive technique to train surgeons in phacoemulsification using a goat′s eye integrated with a human cataractous nucleus is described. The goat′s eye is placed on a bed of cotton within the lumen of a cylindrical container. This is then mounted on a rectangular thermocol so that the limbus is presented at the surgical field. After making a clear corneal entry with a keratome, the trainer makes a 5-5.5 mm continuous curvilinear capsulorhexis in the anterior lens capsule, creates a crater of adequate depth in the cortex and inserts the human nucleus within this crater in the goat′s capsular bag. The surgical wound is sutured, and the goat′s eye is ready for training. Creating the capsulorhexis with precision and making the crater of adequate depth to snugly accommodate the human nucleus are the most important steps to prevent excessive wobbling of the nucleus while training.

  15. Goat's eye integrated with a human cataractous lens: A training model for phacoemulsification.

    Science.gov (United States)

    Sengupta, Sabyasachi; Dhanapal, Praveen; Nath, Manas; Haripriya, Aravind; Venkatesh, Rengaraj

    2015-03-01

    A relatively simple and inexpensive technique to train surgeons in phacoemulsification using a goat's eye integrated with a human cataractous nucleus is described. The goat's eye is placed on a bed of cotton within the lumen of a cylindrical container. This is then mounted on a rectangular thermocol so that the limbus is presented at the surgical field. After making a clear corneal entry with a keratome, the trainer makes a 5-5.5 mm continuous curvilinear capsulorhexis in the anterior lens capsule, creates a crater of adequate depth in the cortex and inserts the human nucleus within this crater in the goat's capsular bag. The surgical wound is sutured, and the goat's eye is ready for training. Creating the capsulorhexis with precision and making the crater of adequate depth to snugly accommodate the human nucleus are the most important steps to prevent excessive wobbling of the nucleus while training.

  16. Dosimetric Comparison of Simulated Human Eye And Water Phantom in Investigation of Iodine Source Effects on Tumour And Healthy Tissues

    International Nuclear Information System (INIS)

    Sadi, A.S.; Masoudi, F.S. K.N.Toosi University of Technology

    2011-01-01

    For better clinical analysis in ophthalmic brachytherapy dosimetry, there is a need for the dose determination in different parts of the eye, so simulating the eye and defining the material of any parts of that, is helpful for better investigating dosimetry in human eye. However in brachytherapy dosimetry, it is common to consider the water phantom as human eye globe. In this work, a full human eye is simulated with MCNP-4C code by considering all parts of the eye like; lens, cornea, retina, choroid, sclera, anterior chamber, optic nerve, bulk of the eye comprising vitreous body and tumour. The average dose in different parts of this full model of human eye is determined and the results are compared with the dose calculated in water phantom. The central axes depth dose and the dose in whole of the tumour for these two simulated eye model are calculated too, and the results are compared. At long last, as the aim of this work is comparing the result of investigating dosimetry between two water phantom as human eye and simulated eye globe, the ratios of the absorbed dose by the healthy tissues to the absorbed dose by the tumour are calculated in these simulations and the comparison between results is done eventually.

  17. Geometrical theory to predict eccentric photorefraction intensity profiles in the human eye

    Science.gov (United States)

    Roorda, Austin; Campbell, Melanie C. W.; Bobier, W. R.

    1995-08-01

    In eccentric photorefraction, light returning from the retina of the eye is photographed by a camera focused on the eye's pupil. We use a geometrical model of eccentric photorefraction to generate intensity profiles across the pupil image. The intensity profiles for three different monochromatic aberration functions induced in a single eye are predicted and show good agreement with the measured eccentric photorefraction intensity profiles. A directional reflection from the retina is incorporated into the calculation. Intensity profiles for symmetric and asymmetric aberrations are generated and measured. The latter profile shows a dependency on the source position and the meridian. The magnitude of the effect of thresholding on measured pattern extents is predicted. Monochromatic aberrations in human eyes will cause deviations in the eccentric photorefraction measurements from traditional crescents caused by defocus and may cause misdiagnoses of ametropia or anisometropia. Our results suggest that measuring refraction along the vertical meridian is preferred for screening studies with the eccentric photorefractor.

  18. Importance of non-synonymous OCA2 variants in human eye colour prediction

    DEFF Research Database (Denmark)

    Andersen, Jeppe Dyrberg; Pietroni, Carlotta; Johansen, Peter

    2016-01-01

    in the promotor region of OCA2 (OMIM #611409). Nevertheless, many eye colors cannot be explained by only considering rs12913832:A>G. Methods: In this study, we searched for additional variants in OCA2 to explain human eye color by sequencing a 500 kbp region, encompassing OCA2 and its promotor region. Results: We...... identified three nonsynonymous OCA2 variants as important for eye color, including rs1800407:G>A (p.Arg419Gln) and two variants, rs74653330:A>T (p.Ala481Thr) and rs121918166:G>A (p.Val443Ile), not previously described as important for eye color variation. It was shown that estimated haplotypes consisting...

  19. A human capital predictive model for agent performance in contact centres

    Directory of Open Access Journals (Sweden)

    Chris Jacobs

    2011-10-01

    Research purpose: The primary focus of this article was to develop a theoretically derived human capital predictive model for agent performance in contact centres and Business Process Outsourcing (BPO based on a review of current empirical research literature. Motivation for the study: The study was motivated by the need for a human capital predictive model that can predict agent and overall business performance. Research design: A nonempirical (theoretical research paradigm was adopted for this study and more specifically a theory or model-building approach was followed. A systematic review of published empirical research articles (for the period 2000–2009 in scholarly search portals was performed. Main findings: Eight building blocks of the human capital predictive model for agent performance in contact centres were identified. Forty-two of the human capital contact centre related articles are detailed in this study. Key empirical findings suggest that person– environment fit, job demands-resources, human resources management practices, engagement, agent well-being, agent competence; turnover intention; and agent performance are related to contact centre performance. Practical/managerial implications: The human capital predictive model serves as an operational management model that has performance implications for agents and ultimately influences the contact centre’s overall business performance. Contribution/value-add: This research can contribute to the fields of human resource management (HRM, human capital and performance management within the contact centre and BPO environment.

  20. Comparison of Corneal Deformation Parameters in Keratoconic and Normal Eyes Using a Non-contact Tonometer With a Dynamic Ultra-High-Speed Scheimpflug Camera.

    Science.gov (United States)

    Mercer, Ryan N; Waring, George O; Roberts, Cynthia J; Jhanji, Vishal; Wang, Yumeng; Filho, Joao S; Hemings, Richard A; Rocha, Karolinne M

    2017-09-01

    To evaluate and compare biomechanical properties in normal and keratoconic eyes using a dynamic ultra-high-speed Scheimpflug camera equipped with a non-contact tonometer (Corvis ST; Oculus Optikgeräte GmbH, Wetzlar, Germany). This retrospective study evaluated 89 eyes (47 normal, 42 keratoconic) and a validation arm of 72 eyes (33 normal, 39 keratoconic) using the Corvis ST. A diagnosis of keratoconus was established by clinical findings confirmed by topography and tomography. Dynamic corneal response parameters collected by the Corvis ST (A1 velocity, deformation amplitude [DA], DA Ratio Max 1mm, and Max Inverse Radius) and a stiffness parameter at first applanation (SP-A1) were incorporated into a novel logistic regression equation (DCR index). Area under the receiver operating curve (AUC) was used to assess the sensitivity and specificity of the DCR index. DA, DA Ratio Max 1mm, Max Inverse Radius, and SP-A1 were each found to be statistically significantly different between normal and keratoconic eyes (Mann-Whitney test [independent samples]; P = .0077, < .0001, < .0001, and < .0001, respectively; significance level: P < .05). DCR index demonstrated high sensitivity, specificity, and overall correct detection rate (92.9%, 95.7%, and 94.4%, respectively; AUC = 98.5). The sensitivity and overall correct detection rate improved when eyes with Topographical Keratoconus Classification grades (TKC) greater than 0 were reevaluated (from 92.9% to 96.6% and from 94.4% to 96.1%, respectively). Combining multiple biomechanical parameters (A1 velocity, DA, DA Ratio Max 1mm, Max Inverse Radius, and SP-A1) into a logistic regression equation allows for high sensitivity and specificity for distinguishing keratoconic from normal eyes. [J Refract Surg. 2017;33(9):625-631.]. Copyright 2017, SLACK Incorporated.

  1. Towards Quantum Experiments with Human Eye Detectors Based on Cloning via Stimulated Emission ?

    Science.gov (United States)

    De Martini, Francesco

    2010-05-01

    In a recent theoretical paper published in Physical Review Letters, Sekatsky, Brunner, Branciard, Gisin, Simon report an extended investigation on some properties of the human eye that affect its behavior as a quantum detector. We believe that the content of this work, albeit appealing at fist sight, is highly questionable simply because the human eye cannot be adopted as a sensing device within any quantum measurement apparatus. Furthermore, the criticism raised by these Authors against a real experiment on Micro—Macro entanglement recently published in Physical Review Letters (100, 253601, 2008) is found misleading and misses its target.

  2. Contact-Free Heartbeat Signal for Human Identification and Forensics

    DEFF Research Database (Denmark)

    Nasrollahi, Kamal; Haque, Mohammad Ahsanul; Irani, Ramin

    2017-01-01

    on the subject’s body. Though it might be possible to use touch-based sensors in applications like patient monitoring, it won’t be that easy to use them in identification and forensics applications, espe- cially if subjects are not cooperative. To deal with this problem, recently computer vision techniques have......The heartbeat signal, which is one of the physiological signals, is of great importance in many real-world applications, for example, in patient monitoring and biometric recognition. The traditional methods for measuring such this signal use contact-based sensors that need to be installed...

  3. Statistical characteristics of aberrations of human eyes after small incision lenticule extraction surgery and analysis of visual performance with individual eye model.

    Science.gov (United States)

    Lou, Qiqi; Wang, Yan; Wang, Zhaoqi; Liu, Yongji; Zhang, Lin; Fang, Hui

    2015-09-01

    Preoperative and postoperative wavefront aberrations of 73 myopic eyes with small incision lenticule extraction surgery are analyzed in this paper. Twenty-eight postoperative individual eye models are constructed to investigate the visual acuity (VA) of human eyes. Results show that in photopic condition, residual defocus, residual astigmatism, and higher-order aberrations are relatively small. 100% of eyes reach a VA of 0.8 or better, and 89.3% of eyes reach a VA of 1.0 or better. In scotopic condition, the residual defocus and the higher-order aberrations are, respectively, 1.9 and 8.5 times the amount of that in photopic condition, and the defocus becomes the main factor attenuating visual performance.

  4. APPLICATION OF EYE TRACKING FOR MEASUREMENT AND EVALUATION IN HUMAN FACTORS STUDIES IN CONTROL ROOM MODERNIZATION

    Energy Technology Data Exchange (ETDEWEB)

    Kovesdi, C.; Spielman, Z.; LeBlanc, K.; Rice, B.

    2017-05-01

    An important element of human factors engineering (HFE) pertains to measurement and evaluation (M&E). The role of HFE-M&E should be integrated throughout the entire control room modernization (CRM) process and be used for human-system performance evaluation and diagnostic purposes with resolving potential human engineering deficiencies (HEDs) and other human machine interface (HMI) design issues. NUREG-0711 describes how HFE in CRM should employ a hierarchical set of measures, particularly during integrated system validation (ISV), including plant performance, personnel task performance, situation awareness, cognitive workload, and anthropometric/ physiological factors. Historically, subjective measures have been primarily used since they are easier to collect and do not require specialized equipment. However, there are pitfalls with relying solely on subjective measures in M&E such that negatively impact reliability, sensitivity, and objectivity. As part of comprehensively capturing a diverse set of measures that strengthen findings and inferences made of the benefits from emerging technologies like advanced displays, this paper discusses the value of using eye tracking as an objective method that can be used in M&E. A brief description of eye tracking technology and relevant eye tracking measures is provided. Additionally, technical considerations and the unique challenges with using eye tracking in full-scaled simulations are addressed. Finally, this paper shares preliminary findings regarding the use of a wearable eye tracking system in a full-scale simulator study. These findings should help guide future full-scale simulator studies using eye tracking as a methodology to evaluate human-system performance.

  5. Migration of human antigen-presenting cells in a human skin graft onto nude mice model after contact sensitization

    NARCIS (Netherlands)

    Hoefakker, S.; Balk, H.P.; Boersma, W.J.A.; Joost, T. van; Notten, W.R.F.; Claassen, E.

    1995-01-01

    Fluorescent contact chemical allergens provoke sensitization after application on both syngeneic and allogeneic skin grafts in mice. We attempted to determine whether the functional activity in a contact sensitization response of human skin graft was affected at the level of antigen uptake and

  6. Mathematical models of the dynamics of the human eye

    CERN Document Server

    Collins, Richard

    1980-01-01

    A rich and abundant literature has developed during the last half century dealing with mechanical aspects of the eye, mainly from clinical and, experimental points of view. For the most part, workers have attempted to shed light on the complex set of conditions known by the general term glaucoma. These conditions are characterised by an increase in intraocular pressure sufficient to cause de­ generation of the optic disc and concomitant defects in the visual field, which, if not controlled, lead to inevitable permanent blindness. In the United States alone, an estimated 50,000 persons are blind as a result of glaucoma, which strikes about 2% of the population over 40 years of age (Vaughan and Asbury, 1974). An understanding of the underlying mechanisms of glaucoma is hindered by the fact that elevated intraocular pressure, like a runny nose, is but a symptom which may have a variety of causes. Only by turning to the initial pathology can one hope to understand this important class of medical problems.

  7. Safety and efficacy of topical azithromycin ophthalmic solution 1.0% in the treatment of contact lens-related dry eye.

    Science.gov (United States)

    Nichols, Jason J; Bickle, Katherine M; Zink, Richard C; Schiewe, Michael D; Haque, Reza M; Nichols, Kelly K

    2012-03-01

    The purpose of this pilot study was to evaluate the safety and efficacy of azithromycin ophthalmic solution 1% in patients with contact lens-related dry eye (CLDE). This was a 4-week, single-center, open-label clinical trial in patients diagnosed with CLDE using the Contact Lens Dry Eye Questionnaire (CLDEQ). Fifty patients were enrolled in this study. The patients were randomized to 1 of 2 treatment groups: azithromycin ophthalmic solution administered bid on days 1 and 2 and on days 3 to 29±1 or Visine for Contacts rewetting drops administered qid on days 1 to 29±1. The patient diaries were used daily to collect data on comfortable and total contact lens wear time and ocular dryness throughout the treatment period. Tear osmolarity, fluorescein corneal staining, and visual acuity were also assessed during clinic visits. Fifty patients were enrolled, and 44 completed the study. One patient discontinued in the azithromycin group, and five patients discontinued in the rewetting drops group because of adverse events. A statistically significant increase in mean comfortable contact lens wear time from baseline was observed for the subjects treated with azithromycin ophthalmic solution as compared with the subjects treated with rewetting drops at week 4 (P=0.004; primary endpoint), in addition to weeks 2 and 3. The improvement in the mean comfortable wear time for the patients in the azithromycin treatment group exceeded 2 hrs throughout the treatment period (weeks 1-4). No significant differences were observed between the groups for total wear time, low contrast visual acuity, or tear osmolarity. Subject-rated ocular dryness (PM time assessments) was significantly improved from baseline in the subjects treated with azithromycin ophthalmic solution as compared with those treated with rewetting drops at weeks 2 and 3 endpoints (P=0.015 for each week). Additionally, a statistical difference was observed in favor of the azithromycin treatment group at week 2 for the

  8. Dose conversion coefficients for neutron exposure to the lens of the human eye

    International Nuclear Information System (INIS)

    Manger, Ryan P.; Bellamy, Michael B.; Eckerman, Keith F.

    2011-01-01

    Dose conversion coefficients for the lens of the human eye have been calculated for neutron exposure at energies from 1 x 10 -9 to 20 MeV and several standard orientations: anterior-to-posterior, rotational and right lateral. MCNPX version 2.6.0, a Monte Carlo-based particle transport package, was used to determine the energy deposited in the lens of the eye. The human eyeball model was updated by partitioning the lens into sensitive and insensitive volumes as the anterior portion (sensitive volume) of the lens being more radiosensitive and prone to cataract formation. The updated eye model was used with the adult UF-ORNL mathematical phantom in the MCNPX transport calculations.

  9. Dose conversion coefficients for neutron exposure to the lens of the human eye

    International Nuclear Information System (INIS)

    Manger, R. P.; Bellamy, M. B.; Eckerman, K. F.

    2012-01-01

    Dose conversion coefficients for the lens of the human eye have been calculated for neutron exposure at energies from 1 x 10 -9 to 20 MeV and several standard orientations: anterior-to-posterior, rotational and right lateral. MCNPX version 2.6.0, a Monte Carlo-based particle transport package, was used to determine the energy deposited in the lens of the eye. The human eyeball model was updated by partitioning the lens into sensitive and insensitive volumes as the anterior portion (sensitive volume) of the lens being more radiosensitive and prone to cataract formation. The updated eye model was used with the adult UF-ORNL mathematical phantom in the MCNPX transport calculations. (authors)

  10. The effect of human image in B2C website design: an eye-tracking study

    Science.gov (United States)

    Wang, Qiuzhen; Yang, Yi; Wang, Qi; Ma, Qingguo

    2014-09-01

    On B2C shopping websites, effective visual designs can bring about consumers' positive emotional experience. From this perspective, this article developed a research model to explore the impact of human image as a visual element on consumers' online shopping emotions and subsequent attitudes towards websites. This study conducted an eye-tracking experiment to collect both eye movement data and questionnaire data to test the research model. Questionnaire data analysis showed that product pictures combined with human image induced positive emotions among participants, thus promoting their attitudes towards online shopping websites. Specifically, product pictures with human image first produced higher levels of image appeal and perceived social presence, thus stimulating higher levels of enjoyment and subsequent positive attitudes towards the websites. Moreover, a moderating effect of product type was demonstrated on the relationship between the presence of human image and the level of image appeal. Specifically, human image significantly increased the level of image appeal when integrated in entertainment product pictures while this relationship was not significant in terms of utilitarian products. Eye-tracking data analysis further supported these results and provided plausible explanations. The presence of human image significantly increased the pupil size of participants regardless of product types. For entertainment products, participants paid more attention to product pictures integrated with human image whereas for utilitarian products more attention was paid to functional information of products than to product pictures no matter whether or not integrated with human image.

  11. Mechanical model of human eye compliance for volumetric occlusion break surge measurements.

    Science.gov (United States)

    Dyk, David W; Miller, Kevin M

    2018-02-01

    To develop a mechanical model of human eye compliance for volumetric studies. Alcon Research, Ltd., Lake Forest, California, USA. Experimental study. Enucleated human eyes underwent pressurization and depressurization cycles with peak intraocular pressures (IOPs) of 60 to 100 mm Hg; anterior chamber pressure and volume changes were measured. Average net volume change curves were calculated as a function of IOP for each eye. Overall mean volumes were computed from each eye's average results at pressure points extrapolated over the range of 5 to 90 mm Hg. A 2-term exponential function was fit to these results. A fluid chamber with a displaceable piston was created as a mechanical model of this equation. A laser confocal displacement meter was used to measure piston displacement. A test bed incorporated the mechanical model with a mounted phacoemulsification probe and allowed for simulated occlusion breaks. Surge volume was calculated from piston displacement. An exponential function, V = C 1 × exp(C 2 × IOP) + C 3  × exp(C 4  × IOP) - V 0 , where V, the volume, was fit to the final depressurization curve obtained from 15 enucleated human eyes. The C 1 through C 4 values were -0.07141, -0.23055, -0.14972, and -0.02006, respectively. The equation was modeled using a piston system with 3 parallel springs that engaged serially. The mechanical model mimicked depressurization curves observed in human cadaver eyes. The resulting mechanical compliance model measured ocular volumetric changes and thus would be helpful in characterizing the postocclusion break surge response. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. Social interactions through the eyes of macaques and humans.

    Directory of Open Access Journals (Sweden)

    Richard McFarland

    Full Text Available Group-living primates frequently interact with each other to maintain social bonds as well as to compete for valuable resources. Observing such social interactions between group members provides individuals with essential information (e.g. on the fighting ability or altruistic attitude of group companions to guide their social tactics and choice of social partners. This process requires individuals to selectively attend to the most informative content within a social scene. It is unclear how non-human primates allocate attention to social interactions in different contexts, and whether they share similar patterns of social attention to humans. Here we compared the gaze behaviour of rhesus macaques and humans when free-viewing the same set of naturalistic images. The images contained positive or negative social interactions between two conspecifics of different phylogenetic distance from the observer; i.e. affiliation or aggression exchanged by two humans, rhesus macaques, Barbary macaques, baboons or lions. Monkeys directed a variable amount of gaze at the two conspecific individuals in the images according to their roles in the interaction (i.e. giver or receiver of affiliation/aggression. Their gaze distribution to non-conspecific individuals was systematically varied according to the viewed species and the nature of interactions, suggesting a contribution of both prior experience and innate bias in guiding social attention. Furthermore, the monkeys' gaze behavior was qualitatively similar to that of humans, especially when viewing negative interactions. Detailed analysis revealed that both species directed more gaze at the face than the body region when inspecting individuals, and attended more to the body region in negative than in positive social interactions. Our study suggests that monkeys and humans share a similar pattern of role-sensitive, species- and context-dependent social attention, implying a homologous cognitive mechanism of

  13. Eye Tracking Based Control System for Natural Human-Computer Interaction

    Directory of Open Access Journals (Sweden)

    Xuebai Zhang

    2017-01-01

    Full Text Available Eye movement can be regarded as a pivotal real-time input medium for human-computer communication, which is especially important for people with physical disability. In order to improve the reliability, mobility, and usability of eye tracking technique in user-computer dialogue, a novel eye control system with integrating both mouse and keyboard functions is proposed in this paper. The proposed system focuses on providing a simple and convenient interactive mode by only using user’s eye. The usage flow of the proposed system is designed to perfectly follow human natural habits. Additionally, a magnifier module is proposed to allow the accurate operation. In the experiment, two interactive tasks with different difficulty (searching article and browsing multimedia web were done to compare the proposed eye control tool with an existing system. The Technology Acceptance Model (TAM measures are used to evaluate the perceived effectiveness of our system. It is demonstrated that the proposed system is very effective with regard to usability and interface design.

  14. Eye Tracking Based Control System for Natural Human-Computer Interaction.

    Science.gov (United States)

    Zhang, Xuebai; Liu, Xiaolong; Yuan, Shyan-Ming; Lin, Shu-Fan

    2017-01-01

    Eye movement can be regarded as a pivotal real-time input medium for human-computer communication, which is especially important for people with physical disability. In order to improve the reliability, mobility, and usability of eye tracking technique in user-computer dialogue, a novel eye control system with integrating both mouse and keyboard functions is proposed in this paper. The proposed system focuses on providing a simple and convenient interactive mode by only using user's eye. The usage flow of the proposed system is designed to perfectly follow human natural habits. Additionally, a magnifier module is proposed to allow the accurate operation. In the experiment, two interactive tasks with different difficulty (searching article and browsing multimedia web) were done to compare the proposed eye control tool with an existing system. The Technology Acceptance Model (TAM) measures are used to evaluate the perceived effectiveness of our system. It is demonstrated that the proposed system is very effective with regard to usability and interface design.

  15. A role of the human thalamus in predicting the perceptual consequences of eye movements.

    Science.gov (United States)

    Ostendorf, Florian; Liebermann, Daniela; Ploner, Christoph J

    2013-01-01

    Internal monitoring of oculomotor commands may help to anticipate and keep track of changes in perceptual input imposed by our eye movements. Neurophysiological studies in non-human primates identified corollary discharge (CD) signals of oculomotor commands that are conveyed via thalamus to frontal cortices. We tested whether disruption of these monitoring pathways on the thalamic level impairs the perceptual matching of visual input before and after an eye movement in human subjects. Fourteen patients with focal thalamic stroke and 20 healthy control subjects performed a task requiring a perceptual judgment across eye movements. Subjects reported the apparent displacement of a target cue that jumped unpredictably in sync with a saccadic eye movement. In a critical condition of this task, six patients exhibited clearly asymmetric perceptual performance for rightward vs. leftward saccade direction. Furthermore, perceptual judgments in seven patients systematically depended on oculomotor targeting errors, with self-generated targeting errors erroneously attributed to external stimulus jumps. Voxel-based lesion-symptom mapping identified an area in right central thalamus as critical for the perceptual matching of visual space across eye movements. Our findings suggest that trans-thalamic CD transmission decisively contributes to a correct prediction of the perceptual consequences of oculomotor actions.

  16. A role of the human thalamus in predicting the perceptual consequences of eye movements

    Directory of Open Access Journals (Sweden)

    Florian eOstendorf

    2013-04-01

    Full Text Available Internal monitoring of oculomotor commands may help to anticipate and keep track of changes in perceptual input imposed by our eye movements. Neurophysiological studies in non-human primates identified corollary discharge signals of oculomotor commands that are conveyed via thalamus to frontal cortices. We tested whether disruption of these monitoring pathways on the thalamic level impairs the perceptual matching of visual input before and after an eye movement in human subjects. Fourteen patients with focal thalamic stroke and twenty healthy control subjects performed a task requiring a perceptual judgment across eye movements. Subjects reported the apparent displacement of a target cue that jumped unpredictably in sync with a saccadic eye movement. In a critical condition of this task, six patients exhibited clearly asymmetric perceptual performance for rightward versus leftward saccade direction. Furthermore, perceptual judgments in seven patients systematically depended on oculomotor targeting errors, with self-generated targeting errors erroneously attributed to external stimulus jumps. Voxel-based lesion-symptom mapping identified an area in right central thalamus as critical for the perceptual matching of visual space across eye movements. Our findings suggest that trans-thalamic corollary discharge transmission decisively contributes to a correct prediction of the perceptual consequences of oculomotor actions.

  17. Comparative Evaluation of Silicone Hydrogel Contact Lenses and Autologous Serum for Management of Sjögren Syndrome-Associated Dry Eye.

    Science.gov (United States)

    Li, Jinyang; Zhang, Xiahua; Zheng, Qinxiang; Zhu, Yirui; Wang, Hui; Ma, Huixiang; Jhanji, Vishal; Chen, Wei

    2015-09-01

    To comparatively evaluate the efficacy of a bandage contact lens (BCL) and autologous serum (AS) eye drops in the management of severe dry eye caused by Sjögren syndrome (SS). In this prospective randomized study, 40 patients with SS were enrolled. Patients were divided into 2 treatment groups: BCL and AS. A total of 37 patients were included, 18 patients (35 eyes) in the AS group and 19 patients (36 eyes) in the BCL group. At the end of 6 weeks, the best-corrected visual acuity improved significantly in the BCL group (0.5 ± 0.3 vs. 0.3 ± 0.2, P = 0.003) but not in the AS group (0.4 ± 0.3 vs. 0.3 ± 0.3, P = 0.11). The best-corrected visual acuity remained stable up to 6 weeks after discontinuation of the BCL (0.5 ± 0.3 vs. 0.4 ± 0.2, P = 0.03). Although the Ocular Surface Disease Index scores decreased significantly after treatment in both groups, patients in the BCL group had lower Ocular Surface Disease Index scores than those in the AS group (53.4 vs. 41.8 at week 3, 47.1 vs. 31.0 at week 6, 52.7 vs. 32.0 at week 12; P = 0.014, dry eye. Clinical Trial Registration—URL: http://www.clinicaltrials.gov. Unique identifier: NCT02147509.

  18. Two eyes, one vision: binocular motion perception in human visual cortex

    NARCIS (Netherlands)

    Barendregt, M.

    2016-01-01

    An important aspect of human vision is the fact that it is binocular, i.e. that we have two eyes. As a result, the brain nearly always receives two slightly different images of the same visual scene. Yet, we only perceive a single image and thus our brain has to actively combine the binocular visual

  19. A Simple Model of the Accommodating Lens of the Human Eye

    Science.gov (United States)

    Oommen, Vinay; Kanthakumar, Praghalathan

    2014-01-01

    The human eye is often discussed as optically equivalent to a photographic camera. The iris is compared with the shutter, the pupil to the aperture, and the retina to the film, and both have lens systems to focus rays of light. Although many similarities exist, a major difference between the two systems is the mechanism involved in focusing an…

  20. Different cellular effects of four anti-inflammatory eye drops on human corneal epithelial cells: independent in active components.

    Science.gov (United States)

    Qu, Mingli; Wang, Yao; Yang, Lingling; Zhou, Qingjun

    2011-01-01

    To evaluate and compare the cellular effects of four commercially available anti-inflammatory eye drops and their active components on human corneal epithelial cells (HCECs) in vitro. The cellular effects of four eye drops (Bromfenac Sodium Hydrate Eye Drops, Pranoprofen Eye Drops, Diclofenac Sodium Eye Drops, and Tobramycin & Dex Eye Drops) and their corresponding active components were evaluated in an HCEC line with five in vitro assays. Cell proliferation and migration were measured using 3-(4,5)-dimethylthiahiazo (-z-y1)-3 5-di-phenytetrazoliumromide (MTT) assay and transwell migration assay. Cell damage was determined with the lactate dehydrogenase (LDH) assay. Cell viability and median lethal time (LT₅₀) were measured by 7-amino-actinomycin D (7-AAD) staining and flow cytometry analysis. Cellular effects after exposure of HCECs to the four anti-inflammatory eye drops were concentration dependent. The differences of cellular toxicity on cell proliferation became significant at lower concentrations (Eye Drops showed significant increasing effects on cell damage and viability when compared with the other three solutions. Tobramycin & Dex Eye Drops inhibited the migration of HCECs significantly. Tobramycin & Dex Eye Drops showed the quickest effect on cell viability: the LT₅₀ was 3.28, 9.23, 10.38, and 23.80 min for Tobramycin & Dex Eye Drops, Diclofenac Sodium Eye Drops, Pranoprofen Eye Drops, and Bromfenac Sodium Hydrate Eye Drops, respectively. However, the comparisons of cellular toxicity revealed significant differences between the eye drops and their active components under the same concentration. The corneal epithelial toxicity differences among the active components of the four eye drops became significant as higher concentration (>0.020%). The four anti-inflammatory eye drops showed different cellular effects on HCECs, and the toxicity was not related with their active components, which provides new reference for the clinical application and drug

  1. The neurophysiology of human touch and eye gaze and its effects on therapeutic relationships and healing: a scoping review protocol.

    Science.gov (United States)

    Kerr, Fiona; Wiechula, Rick; Feo, Rebecca; Schultz, Tim; Kitson, Alison

    2016-04-01

    The objective of this scoping review is to examine and map the range of neurophysiological impacts of human touch and eye gaze, and better understand their possible links to the therapeutic relationship and the process of healing. The specific question is "what neurophysiological impacts of human touch and eye gaze have been reported in relation to therapeutic relationships and healing?"

  2. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... Costume Contact Lenses Can Ruin Vision Eye Makeup Safety In fact, it is illegal to sell colored ...

  3. In vivo cartilage contact deformation in the healthy human tibiofemoral joint.

    Science.gov (United States)

    Bingham, J T; Papannagari, R; Van de Velde, S K; Gross, C; Gill, T J; Felson, D T; Rubash, H E; Li, G

    2008-11-01

    In vivo cartilage contact deformation is instrumental for understanding human joint function and degeneration. This study measured the total deformation of contacting articular cartilage in the human tibiofemoral joint during in vivo weight-bearing flexion. Eleven healthy knees were magnetic resonance (MR) scanned and imaged with a dual fluoroscopic system while the subject performed a weight-bearing single-leg lunge. The tibia, femur and associated articulating cartilage were constructed from the MR images and combined with the dual fluoroscopic images to determine in vivo cartilage contact deformation from full extension to 120 degrees of flexion. In both compartments, minimum peak compartmental contact deformation occurred at 30 degrees of flexion (24 +/- 6% medial, 17 +/- 7% lateral) and maximum peak compartmental deformation occurred at 120 degrees of flexion (30 +/- 13% medial, 30 +/- 10% lateral) during the weight-bearing flexion from full extension to 120 degrees. Average medial contact areas and peak contact deformations were significantly greater than lateral compartment values (P In addition, cartilage thickness in regions of contact was on average 1.4- and 1.1-times thicker than the average thickness of the tibial and femoral cartilage surfaces, respectively (P line knowledge for investigating the effects of various knee injuries on joint contact biomechanics and the aetiology of cartilage degeneration.

  4. Analysis of the speckle properties in a laser projection system based on a human eye model.

    Science.gov (United States)

    Cui, Zhe; Wang, Anting; Ma, Qianli; Ming, Hai

    2014-03-01

    In this paper, the properties of the speckle that is observed by humans in laser projection systems are theoretically analyzed. The speckle pattern on the fovea of the human retina is numerically simulated by introducing a chromatic human eye model. The results show that the speckle contrast experienced by humans is affected by the light intensity of the projected images and the wavelength of the laser source when considering the paracentral vision. Furthermore, the image quality is also affected by these two parameters. We believe that these results are useful for evaluating the speckle noise in laser projection systems.

  5. The effects of ultraviolet-A radiation on visual evoked potentials in the young human eye

    International Nuclear Information System (INIS)

    Sanford, B.E.; Beacham, S.; Hanifin, J.P.; Hannon, P.; Streletz, L.; Sliney, D.; Brainard, G.C.

    1996-01-01

    A recent study from this laboratory using visual evoked potentials (VEPs) demonstrated that children's eyes are capable of detecting ultraviolet radiation. The aim of this study was to compare dose-response relationships in two age groups, 6-10 years (n=10) and 20-25 years (n=10). Under photopic viewing conditions (550 lux), exposures of monochromatic UV-A (339 nm) and visible radiation (502 nm) were correlated to VEPs. The results demonstrate that monochromatic UV-A can elicit age and dose dependent responses in the human visual system, suggesting that the eyes of children are more responsive to UV stimuli than the eyes of young adults. (au) 17 refs

  6. Temperature elevation in the eye of anatomically based human head models for plane-wave exposures

    International Nuclear Information System (INIS)

    Hirata, A; Watanabe, S; Fujiwara, O; Kojima, M; Sasaki, K; Shiozawa, T

    2007-01-01

    This study investigated the temperature elevation in the eye of anatomically based human head models for plane-wave exposures. The finite-difference time-domain method is used for analyzing electromagnetic absorption and temperature elevation. The eyes in the anatomic models have average dimensions and weight. Computational results show that the ratio of maximum temperature in the lens to the eye-average SAR (named 'heating factor for the lens') is almost uniform (0.112-0.147 deg. C kg W -1 ) in the frequency region below 3 GHz. Above 3 GHz, this ratio increases gradually with an increase of frequency, which is attributed to the penetration depth of an electromagnetic wave. Particular attention is paid to the difference in the heating factor for the lens between this study and earlier works. Considering causes clarified in this study, compensated heating factors in all these studies are found to be in good agreement

  7. Objective measurement of intraocular forward light scatter using Hartmann-Shack spot patterns from clinical aberrometers. Model-eye and human-eye study.

    Science.gov (United States)

    Cerviño, Alejandro; Bansal, Dheeraj; Hosking, Sarah L; Montés-Micó, Robert

    2008-07-01

    To apply software-based image-analysis tools to objectively determine intraocular scatter determined from clinically derived Hartmann-Shack patterns. Aston Academy of Life Sciences, Aston University, Birmingham, United Kingdom, and Department of Optics, University of Valencia, Valencia, Spain. Purpose-designed image-analysis software was used to quantify scatter from centroid patterns obtained using a clinical Hartmann-Shack analyzer (WASCA, Zeiss/Meditec). Three scatter values, as the maximum standard deviation within a lenslet for all lenslets in the pattern, were obtained in 6 model eyes and 10 human eyes. In the model-eye sample, patterns were obtained in 4 sessions: 2 without realigning between measurements, 1 with realignment, and 1 with an angular shift of 6 degrees from the instrument axis. Three measurements were made in the human eyes with the C-Quant straylight meter (Oculus) to obtain psychometric and objective measures of retinal straylight. Analysis of variance, intraclass correlation coefficients, coefficient of repeatability (CoR), and correlations were used to determine intrasession and intersession repeatability and the relationship between measures. No significant differences were found between the sessions in the model eye (P=.234). The mean CoR was less than 10% in all model- and human-eye sessions. After incomplete patterns were removed, good correlation was achieved between psychometric and objective scatter measurements despite the small sample size (n=6; r=-0.831; P=.040). The methodology was repeatable in model and human eyes, strong against realignment and misalignment, and sensitive. Clinical application would benefit from effective use of the sensor's dynamic range.

  8. Modeling the influence of LASIK surgery on optical properties of the human eye

    Science.gov (United States)

    Szul-Pietrzak, Elżbieta; Hachoł, Andrzej; Cieślak, Krzysztof; Drożdż, Ryszard; Podbielska, Halina

    2011-11-01

    The aim was to model the influence of LASIK surgery on the optical parameters of the human eye and to ascertain which factors besides the central corneal radius of curvature and central thickness play the major role in postsurgical refractive change. Ten patients were included in the study. Pre- and postsurgical measurements included standard refraction, anterior corneal curvature and pachymetry. The optical model used in the analysis was based on the Le Grand and El Hage schematic eye, modified by the measured individual parameters of corneal geometry. A substantial difference between eye refractive error measured after LASIK and estimated from the eye model was observed. In three patients, full correction of the refractive error was achieved. However, analysis of the visual quality in terms of spot diagrams and optical transfer functions of the eye optical system revealed some differences in these measurements. This suggests that other factors besides corneal geometry may play a major role in postsurgical refraction. In this paper we investigated whether the biomechanical properties of the eyeball and changes in intraocular pressure could account for the observed discrepancies.

  9. Edge detection of iris of the eye for human biometric identification system

    Directory of Open Access Journals (Sweden)

    Kateryna O. Tryfonova

    2015-03-01

    Full Text Available Method of human biometric identification by iris of the eye is considered as one of the most accurate and reliable methods of identification. Aim of the research is to solve the problem of edge detection of digital image of the human eye iris to be able to implement human biometric identification system by means of mobile device. To achieve this aim the algorithm of edge detection by Canny is considered in work. It consists of the following steps: smoothing, finding gradients, non-maximum suppression, double thresholding with hysteresis. The software implementation of the Canny algorithm is carried out for the Android mobile platform with the use of high level programming language Java.

  10. Thermal behavior of human eye in relation with change in blood perfusion, porosity, evaporation and ambient temperature.

    Science.gov (United States)

    Rafiq, Aasma; Khanday, M A

    2016-12-01

    Extreme environmental and physiological conditions present challenges for thermal processes in body tissues including multi-layered human eye. A mathematical model has been formulated in this direction to study the thermal behavior of the human eye in relation with the change in blood perfusion, porosity, evaporation and environmental temperatures. In this study, a comprehensive thermal analysis has been performed on the multi-layered eye using Pennes' bio-heat equation with appropriate boundary and interface conditions. The variational finite element method and MATLAB software were used for the solution purpose and simulation of the results. The thermoregulatory effect due to blood perfusion rate, porosity, ambient temperature and evaporation at various regions of human eye was illustrated mathematically and graphically. The main applications of this model are associated with the medical sciences while performing laser therapy and other thermoregulatory investigation on human eye. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Effects of aqueous humor hydrodynamics on human eye heat transfer under external heat sources.

    Science.gov (United States)

    Tiang, Kor L; Ooi, Ean H

    2016-08-01

    The majority of the eye models developed in the late 90s and early 00s considers only heat conduction inside the eye. This assumption is not entirely correct, since the anterior and posterior chambers are filled aqueous humor (AH) that is constantly in motion due to thermally-induced buoyancy. In this paper, a three-dimensional model of the human eye is developed to investigate the effects AH hydrodynamics have on the human eye temperature under exposure to external heat sources. If the effects of AH flow are negligible, then future models can be developed without taking them into account, thus simplifying the modeling process. Two types of external thermal loads are considered; volumetric and surface irradiation. Results showed that heat convection due to AH flow contributes to nearly 95% of the total heat flow inside the anterior chamber. Moreover, the circulation inside the anterior chamber can cause an upward shift of the location of hotspot. This can have significant consequences to our understanding of heat-induced cataractogenesis. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  12. From time series analysis to a biomechanical multibody model of the human eye

    International Nuclear Information System (INIS)

    Pascolo, P.; Carniel, R.

    2009-01-01

    A mechanical model of the human eye is presented aimed at estimating the level of muscular activation. The applicability of the model in the biomedical field is discussed. Human eye movements studied in the laboratory are compared with the ones produced by a virtual eye described in kinematical terms and subject to the dynamics of six actuators, as many as the muscular systems devoted to the eye motion control. The definition of an error function between the experimental and the numerical response and the application of a suitable law that links activation and muscular force are at the base of the proposed methodology. The aim is the definition of a simple conceptual tool that could help the specialist in the diagnosis of potential physiological disturbances of saccadic and nystagmic movements but can also be extended in a second phase when more sophisticated data become available. The work is part of a collaboration between the Functional Mechanics Laboratory of the University and the Neurophysiopatology Laboratory of the 'S. Maria della Misericordia' Hospital in Udine, Italy.

  13. Simulated human eye retina adaptive optics imaging system based on a liquid crystal on silicon device

    International Nuclear Information System (INIS)

    Jiang Baoguang; Cao Zhaoliang; Mu Quanquan; Hu Lifa; Li Chao; Xuan Li

    2008-01-01

    In order to obtain a clear image of the retina of model eye, an adaptive optics system used to correct the wave-front error is introduced in this paper. The spatial light modulator that we use here is a liquid crystal on a silicon device instead of a conversional deformable mirror. A paper with carbon granule is used to simulate the retina of human eye. The pupil size of the model eye is adjustable (3-7 mm). A Shack–Hartman wave-front sensor is used to detect the wave-front aberration. With this construction, a value of peak-to-valley is achieved to be 0.086 λ, where λ is wavelength. The modulation transfer functions before and after corrections are compared. And the resolution of this system after correction (691p/m) is very close to the dirraction limit resolution. The carbon granule on the white paper which has a size of 4.7 μm is seen clearly. The size of the retina cell is between 4 and 10 mu;m. So this system has an ability to image the human eye's retina. (classical areas of phenomenology)

  14. Intraoperative length and tension curves of human eye muscles. Including stiffness in passive horizontal eye movement in awake volunteers

    NARCIS (Netherlands)

    H.J. Simonsz (Huib); G.H. Kolling (Gerold); H. Kaufmann (Herbert); B. van Dijk (Bob)

    1986-01-01

    textabstractIntraoperative continuous-registration length and tension curves of attached and detached eye muscles were made in 18 strabismic patients under general anesthesia. For relaxed eye muscles, we found an exponential relation between length and tension. An increased stiffness was quantified

  15. Correlation between the concentration of serum polychlorinated biphenyls (PCBs) in pregnant cynomolgus monkeys and their offspring's behavioral scores in eye-contact test and finger maze learning test

    Energy Technology Data Exchange (ETDEWEB)

    Negishi, T. [Aoyama Gakuin Univ., Kanagawa (Japan); Takasuga, T. [Shimadzu Techno-Research Inc., Kyoto (Japan); Kawasaki, K. [Hoshi Univ., Tokyo (Japan); Kuroda, Y. [CREST Japan Science and Technology Corp., Saitama (Japan); Yoshikawa, Y. [The Univ. of Tokyo (Japan)

    2004-09-15

    A recent review suggested that pre- or perinatal exposure of developing fetuses to dioxins, the widespread environmental contaminants, such as polychrorinated biphenlys (PCBs), induce the irreversible abnormalities in the functions of central nervous system (CNS) in human. These chemicals can be transferred to each fetus and naonate transplacentally and lactationally in rhesus monkey. Several studies also reported the adverse effect of PCB on CNS development in rodents and monkeys as well as on behavior in rodents and monkeys. In the present study, we show a preliminary data about the correlation between the serum concentrations of PCBs in pregnant cynomolgus monkeys (Macaca fascicularis) and the scores of two behavioral tests, eye-contact test and four-step finger maze test, which evaluate consciousness against human observer and learning ability, respectively, in their offspring. This experimental surveillance system using non-human primates would be useful to predict the risk of PCBs exposure in human fetuses because of the similarities of cynomolgus monkey to human with regard to reproduction, developmental parameter, and others.

  16. What interests them in the pictures?--differences in eye-tracking between rhesus monkeys and humans.

    Science.gov (United States)

    Hu, Ying-Zhou; Jiang, Hui-Hui; Liu, Ci-Rong; Wang, Jian-Hong; Yu, Cheng-Yang; Carlson, Synnöve; Yang, Shang-Chuan; Saarinen, Veli-Matti; Rizak, Joshua D; Tian, Xiao-Guang; Tan, Hen; Chen, Zhu-Yue; Ma, Yuan-Ye; Hu, Xin-Tian

    2013-10-01

    Studies estimating eye movements have demonstrated that non-human primates have fixation patterns similar to humans at the first sight of a picture. In the current study, three sets of pictures containing monkeys, humans or both were presented to rhesus monkeys and humans. The eye movements on these pictures by the two species were recorded using a Tobii eye-tracking system. We found that monkeys paid more attention to the head and body in pictures containing monkeys, whereas both monkeys and humans paid more attention to the head in pictures containing humans. The humans always concentrated on the eyes and head in all the pictures, indicating the social role of facial cues in society. Although humans paid more attention to the hands than monkeys, both monkeys and humans were interested in the hands and what was being done with them in the pictures. This may suggest the importance and necessity of hands for survival. Finally, monkeys scored lower in eye-tracking when fixating on the pictures, as if they were less interested in looking at the screen than humans. The locations of fixation in monkeys may provide insight into the role of eye movements in an evolutionary context.

  17. Effect of human milk as a treatment for dry eye syndrome in a mouse model.

    Science.gov (United States)

    Diego, Jose L; Bidikov, Luke; Pedler, Michelle G; Kennedy, Jeffrey B; Quiroz-Mercado, Hugo; Gregory, Darren G; Petrash, J Mark; McCourt, Emily A

    Dry eye syndrome (DES) affects millions of people worldwide. Homeopathic remedies to treat a wide variety of ocular diseases have previously been documented in the literature, but little systematic work has been performed to validate the remedies' efficacy using accepted laboratory models of disease. The purpose of this study was to evaluate the efficacy of human milk and nopal cactus (prickly pear), two widely used homeopathic remedies, as agents to reduce pathological markers of DES. The previously described benzalkonium chloride (BAK) dry eye mouse model was used to study the efficacy of human milk and nopal cactus (prickly pear). BAK (0.2%) was applied to the mouse ocular surface twice daily to induce dry eye pathology. Fluorescein staining was used to verify that the animals had characteristic signs of DES. After induction of DES, the animals were treated with human milk (whole and fat-reduced), nopal, nopal extract derivatives, or cyclosporine four times daily for 7 days. Punctate staining and preservation of corneal epithelial thickness, measured histologically at the end of treatment, were used as indices of therapeutic efficacy. Treatment with BAK reduced the mean corneal epithelial thickness from 36.77±0.64 μm in the control mice to 21.29±3.2 μm. Reduction in corneal epithelial thickness was largely prevented by administration of whole milk (33.2±2.5 μm) or fat-reduced milk (36.1±1.58 μm), outcomes that were similar to treatment with cyclosporine (38.52±2.47 μm), a standard in current dry eye therapy. In contrast, crude or filtered nopal extracts were ineffective at preventing BAK-induced loss of corneal epithelial thickness (24.76±1.78 μm and 27.99±2.75 μm, respectively), as were solvents used in the extraction of nopal materials (26.53±1.46 μm for ethyl acetate, 21.59±5.87 μm for methanol). Epithelial damage, as reflected in the punctate scores, decreased over 4 days of treatment with whole and fat-reduced milk but continued to

  18. A superellipsoid-plane model for simulating foot-ground contact during human gait.

    Science.gov (United States)

    Lopes, D S; Neptune, R R; Ambrósio, J A; Silva, M T

    2016-01-01

    Musculoskeletal models and forward dynamics simulations of human movement often include foot-ground interactions, with the foot-ground contact forces often determined using a constitutive model that depends on material properties and contact kinematics. When using soft constraints to model the foot-ground interactions, the kinematics of the minimum distance between the foot and planar ground needs to be computed. Due to their geometric simplicity, a considerable number of studies have used point-plane elements to represent these interacting bodies, but few studies have provided comparisons between point contact elements and other geometrically based analytical solutions. The objective of this work was to develop a more general-purpose superellipsoid-plane contact model that can be used to determine the three-dimensional foot-ground contact forces. As an example application, the model was used in a forward dynamics simulation of human walking. Simulation results and execution times were compared with a point-like viscoelastic contact model. Both models produced realistic ground reaction forces and kinematics with similar computational efficiency. However, solving the equations of motion with the surface contact model was found to be more efficient (~18% faster), and on average numerically ~37% less stiff. The superellipsoid-plane elements are also more versatile than point-like elements in that they allow for volumetric contact during three-dimensional motions (e.g. rotating, rolling, and sliding). In addition, the superellipsoid-plane element is geometrically accurate and easily integrated within multibody simulation code. These advantages make the use of superellipsoid-plane contact models in musculoskeletal simulations an appealing alternative to point-like elements.

  19. Dose conversion coefficients for photon exposure of the human eye lens

    Science.gov (United States)

    Behrens, R.; Dietze, G.

    2011-01-01

    In recent years, several papers dealing with the eye lens dose have been published, because epidemiological studies implied that the induction of cataracts occurs even at eye lens doses of less than 500 mGy. Different questions were addressed: Which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens? Is a new definition of the dose quantity Hp(3) based on a cylinder phantom to represent the human head necessary? Are current conversion coefficients from fluence to equivalent dose to the lens sufficiently accurate? To investigate the latter question, a realistic model of the eye including the inner structure of the lens was developed. Using this eye model, conversion coefficients for electrons have already been presented. In this paper, the same eye model—with the addition of the whole body—was used to calculate conversion coefficients from fluence (and air kerma) to equivalent dose to the lens for photon radiation from 5 keV to 10 MeV. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are similar between 40 keV and 1 MeV and lower by up to a factor of 5 and 7 for photon energies at about 10 keV and 10 MeV, respectively. Above 1 MeV, the new values (calculated without kerma approximation) should be applied in pure photon radiation fields, while the values adopted by the ICRP in 1996 (calculated with kerma approximation) should be applied in case a significant contribution from secondary electrons originating outside the body is present.

  20. Dose conversion coefficients for photon exposure of the human eye lens

    International Nuclear Information System (INIS)

    Behrens, R; Dietze, G

    2011-01-01

    In recent years, several papers dealing with the eye lens dose have been published, because epidemiological studies implied that the induction of cataracts occurs even at eye lens doses of less than 500 mGy. Different questions were addressed: Which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens? Is a new definition of the dose quantity H p (3) based on a cylinder phantom to represent the human head necessary? Are current conversion coefficients from fluence to equivalent dose to the lens sufficiently accurate? To investigate the latter question, a realistic model of the eye including the inner structure of the lens was developed. Using this eye model, conversion coefficients for electrons have already been presented. In this paper, the same eye model-with the addition of the whole body-was used to calculate conversion coefficients from fluence (and air kerma) to equivalent dose to the lens for photon radiation from 5 keV to 10 MeV. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are similar between 40 keV and 1 MeV and lower by up to a factor of 5 and 7 for photon energies at about 10 keV and 10 MeV, respectively. Above 1 MeV, the new values (calculated without kerma approximation) should be applied in pure photon radiation fields, while the values adopted by the ICRP in 1996 (calculated with kerma approximation) should be applied in case a significant contribution from secondary electrons originating outside the body is present.

  1. The effects of metamaterial on electromagnetic fields absorption characteristics of human eye tissues.

    Science.gov (United States)

    Gasmelseed, Akram; Yunus, Jasmy

    2014-01-01

    The interaction of a dipole antenna with a human eye model in the presence of a metamaterial is investigated in this paper. The finite difference time domain (FDTD) method with convolutional perfectly matched layer (CPML) formulation have been used. A three-dimensional anatomical model of the human eye with resolution of 1.25 mm × 1.25 mm × 1.25 mm was used in this study. The dipole antenna was driven by modulated Gaussian pulse and the numerical study is performed with dipole operating at 900 MHz. The analysis has been done by varying the size and value of electric permittivity of the metamaterial. By normalizing the peak SAR (1 g and 10 g) to 1 W for all examined cases, we observed how the SAR values are not affected by the different permittivity values with the size of the metamaterial kept fixed. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. A soft-contact model for computing safety margins in human prehension.

    Science.gov (United States)

    Singh, Tarkeshwar; Ambike, Satyajit

    2017-10-01

    The soft human digit tip forms contact with grasped objects over a finite area and applies a moment about an axis normal to the area. These moments are important for ensuring stability during precision grasping. However, the contribution of these moments to grasp stability is rarely investigated in prehension studies. The more popular hard-contact model assumes that the digits exert a force vector but no free moment on the grasped object. Many sensorimotor studies use this model and show that humans estimate friction coefficients to scale the normal force to grasp objects stably, i.e. the smoother the surface, the tighter the grasp. The difference between the applied normal force and the minimal normal force needed to prevent slipping is called safety margin and this index is widely used as a measure of grasp planning. Here, we define and quantify safety margin using a more realistic contact model that allows digits to apply both forces and moments. Specifically, we adapt a soft-contact model from robotics and demonstrate that the safety margin thus computed is a more accurate and robust index of grasp planning than its hard-contact variant. Previously, we have used the soft-contact model to propose two indices of grasp planning that show how humans account for the shape and inertial properties of an object. A soft-contact based safety margin offers complementary insights by quantifying how humans may account for surface properties of the object and skin tissue during grasp planning and execution. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Facilitation of tear fluid secretion by 3% diquafosol ophthalmic solution in normal human eyes.

    Science.gov (United States)

    Yokoi, Norihiko; Kato, Hiroaki; Kinoshita, Shigeru

    2014-01-01

    To evaluate the increase in tear fluid volume induced by 3% diquafosol ophthalmic solution in normal human eyes. Prospective, randomized, double-masked, comparative study. Twenty healthy adults (17 males and 3 females; mean age, 38.8 years) underwent topical instillation of 2 ophthalmic solutions, artificial tears in 1 eye and 3% diquafosol ophthalmic solution in the fellow eye, in a masked manner. The radius of curvature of the central lower tear meniscus was measured at 5, 10, 15, 30, and 60 minutes after instillation by use of reflective meniscometry, and subjects' self-evaluated symptoms of wetness and stinging using a visual analog scale. Changes after instillation in the radius of curvature from baseline (artificial tear group vs diquafosol group; mean ± standard error of the mean) were as follows: at 5 minutes, -0.008 ± 0.012 vs 0.045 ± 0.013; at 10 minutes, 0.001 ± 0.014 vs 0.057 ± 0.016; at 15 minutes, -0.012 ± 0.014 vs 0.037 ± 0.019; at 30 minutes, -0.010 ± 0.016 vs 0.030 ± 0.025; and at 60 minutes, -0.029 ± 0.012 vs -0.020 ± 0.012. The diquafosol group showed significantly greater values from 5 to 30 minutes after instillation. Of the 40 eyes, 13 showed abnormal tear film breakup time (≤5 seconds). The diquafosol group had significantly more wetness at 15 minutes after instillation than did the artificial tear group. Topical instillation of 3% diquafosol ophthalmic solution increases tear fluid on the ocular surface for up to 30 minutes in normal human eyes. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Distribution of absorbed dose in human eye simulated by SRNA-2KG computer code

    International Nuclear Information System (INIS)

    Ilic, R.; Pesic, M.; Pavlovic, R.; Mostacci, D.

    2003-01-01

    Rapidly increasing performances of personal computers and development of codes for proton transport based on Monte Carlo methods will allow, very soon, the introduction of the computer planning proton therapy as a normal activity in regular hospital procedures. A description of SRNA code used for such applications and results of calculated distributions of proton-absorbed dose in human eye are given in this paper. (author)

  5. Optics of the human cornea influence the accuracy of stereo eye-tracking methods: a simulation study

    NARCIS (Netherlands)

    Barsingerhorn, A.D.; Boonstra, F.N.; Goossens, H.H.L.M.

    2017-01-01

    Current stereo eye-tracking methods model the cornea as a sphere with one refractive surface. However, the human cornea is slightly aspheric and has two refractive surfaces. Here we used ray-tracing and the Navarro eye-model to study how these optical properties affect the accuracy of different

  6. Use of eye tracking equipment for human reliability analysis applied to complex system operations

    International Nuclear Information System (INIS)

    Pinheiro, Andre Ricardo Mendonça; Prado, Eugenio Anselmo Pessoa do; Martins, Marcelo Ramos

    2017-01-01

    This article will discuss the preliminary results of an evaluation methodology for the analysis and quantification of manual character errors (human), by monitoring cognitive parameters and skill levels in the operation of a complex control system based on parameters provided by a eye monitoring equipment (Eye Tracker). The research was conducted using a simulator (game) that plays concepts of operation of a nuclear reactor with a split sample for evaluation of aspects of learning, knowledge and standard operating within the context addressed. bridge operators were monitored using the EYE TRACKING, eliminating the presence of the analyst in the evaluation of the operation, allowing the analysis of the results by means of multivariate statistical techniques within the scope of system reliability. The experiments aim to observe state change situations such as stops and scheduled departures, incidents assumptions and common operating characteristics. Preliminary results of this research object indicate that technical and cognitive aspects can contribute to improving the reliability of the available techniques in human reliability, making them more realistic both in the context of quantitative approaches to regulatory and training purposes, as well as reduced incidence of human error. (author)

  7. Use of eye tracking equipment for human reliability analysis applied to complex system operations

    Energy Technology Data Exchange (ETDEWEB)

    Pinheiro, Andre Ricardo Mendonça; Prado, Eugenio Anselmo Pessoa do; Martins, Marcelo Ramos, E-mail: andrericardopinheiro@usp.br, E-mail: eugenio.prado@labrisco.usp.br, E-mail: mrmatins@usp.br [Universidade de Sao Paulo (LABRISCO/USP), Sao Paulo, SP (Brazil). Lab. de Análise, Avaliação e Gerenciamento de Risco

    2017-07-01

    This article will discuss the preliminary results of an evaluation methodology for the analysis and quantification of manual character errors (human), by monitoring cognitive parameters and skill levels in the operation of a complex control system based on parameters provided by a eye monitoring equipment (Eye Tracker). The research was conducted using a simulator (game) that plays concepts of operation of a nuclear reactor with a split sample for evaluation of aspects of learning, knowledge and standard operating within the context addressed. bridge operators were monitored using the EYE TRACKING, eliminating the presence of the analyst in the evaluation of the operation, allowing the analysis of the results by means of multivariate statistical techniques within the scope of system reliability. The experiments aim to observe state change situations such as stops and scheduled departures, incidents assumptions and common operating characteristics. Preliminary results of this research object indicate that technical and cognitive aspects can contribute to improving the reliability of the available techniques in human reliability, making them more realistic both in the context of quantitative approaches to regulatory and training purposes, as well as reduced incidence of human error. (author)

  8. Mathematical modeling of laser linear thermal effects on the anterior layer of the human eye

    Science.gov (United States)

    Rahbar, Sahar; Shokooh-Saremi, Mehrdad

    2018-02-01

    In this paper, mathematical analysis of thermal effects of excimer lasers on the anterior side of the human eye is presented, where linear effect of absorption by the human eye is considered. To this end, Argon Fluoride (ArF) and Holmium:Yttrium-Aluminum-Garent (Ho:YAG) lasers are utilized in this investigation. A three-dimensional model of the human eye with actual dimensions is employed and finite element method (FEM) is utilized to numerically solve the governing (Penne) heat transfer equation. The simulation results suggest the corneal temperature of 263 °C and 83.4 °C for ArF and Ho:YAG laser radiations, respectively, and show less heat penetration depth in comparison to the previous reports. Moreover, the heat transfer equation is solved semi-analytically in one-dimension. It is shown that the exploited simulation results are also consistent with those derived from the semi-analytical solution of the Penne heat transfer equation for both types of laser radiations.

  9. Human-Human Interaction Forces and Interlimb Coordination During Side-by-Side Walking With Hand Contact.

    Science.gov (United States)

    Sylos-Labini, Francesca; d'Avella, Andrea; Lacquaniti, Francesco; Ivanenko, Yury

    2018-01-01

    Handholding can naturally occur between two walkers. When people walk side-by-side, either with or without hand contact, they often synchronize their steps. However, despite the importance of haptic interaction in general and the natural use of hand contact between humans during walking, few studies have investigated forces arising from physical interactions. Eight pairs of adult subjects participated in this study. They walked on side-by-side treadmills at 4 km/h independently and with hand contact. Only hand contact-related sensory information was available for unintentional synchronization, while visual and auditory communication was obstructed. Subjects walked at their natural cadences or following a metronome. Limb kinematics, hand contact 3D interaction forces and EMG activity of 12 upper limb muscles were recorded. Overall, unintentional step frequency locking was observed during about 40% of time in 88% of pairs walking with hand contact. On average, the amplitude of contact arm oscillations decreased while the contralateral (free) arm oscillated in the same way as during normal walking. Interestingly, EMG activity of the shoulder muscles of the contact arm did not decrease, and their synergistic pattern remained similar. The amplitude of interaction forces and of trunk oscillations was similar for synchronized and non-synchronized steps, though the synchronized steps were characterized by significantly more regular orientations of interaction forces. Our results further support the notion that gait synchronization during natural walking is common, and that it may occur through interaction forces. Conservation of the proximal muscle activity of the contact (not oscillating) arm is consistent with neural coupling between cervical and lumbosacral pattern generation circuitries ("quadrupedal" arm-leg coordination) during human gait. Overall, the findings suggest that individuals might integrate force interaction cues to communicate and coordinate steps during

  10. Human-Human Interaction Forces and Interlimb Coordination During Side-by-Side Walking With Hand Contact

    Directory of Open Access Journals (Sweden)

    Francesca Sylos-Labini

    2018-03-01

    Full Text Available Handholding can naturally occur between two walkers. When people walk side-by-side, either with or without hand contact, they often synchronize their steps. However, despite the importance of haptic interaction in general and the natural use of hand contact between humans during walking, few studies have investigated forces arising from physical interactions. Eight pairs of adult subjects participated in this study. They walked on side-by-side treadmills at 4 km/h independently and with hand contact. Only hand contact-related sensory information was available for unintentional synchronization, while visual and auditory communication was obstructed. Subjects walked at their natural cadences or following a metronome. Limb kinematics, hand contact 3D interaction forces and EMG activity of 12 upper limb muscles were recorded. Overall, unintentional step frequency locking was observed during about 40% of time in 88% of pairs walking with hand contact. On average, the amplitude of contact arm oscillations decreased while the contralateral (free arm oscillated in the same way as during normal walking. Interestingly, EMG activity of the shoulder muscles of the contact arm did not decrease, and their synergistic pattern remained similar. The amplitude of interaction forces and of trunk oscillations was similar for synchronized and non-synchronized steps, though the synchronized steps were characterized by significantly more regular orientations of interaction forces. Our results further support the notion that gait synchronization during natural walking is common, and that it may occur through interaction forces. Conservation of the proximal muscle activity of the contact (not oscillating arm is consistent with neural coupling between cervical and lumbosacral pattern generation circuitries (“quadrupedal” arm-leg coordination during human gait. Overall, the findings suggest that individuals might integrate force interaction cues to communicate and

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses ... away without suffering an eye injury. However, the natural protective mechanisms of the eye – such as the ...

  12. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Halloween or any time of year, follow these guidelines: Get an eye exam from a licensed eye ... available in Spanish . Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the ...

  13. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... videos on your website Promotional materials for eye health observances EyeSmart resources are also available in Spanish . Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at ...

  14. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... had not been properly fitted by an eye care professional, the lenses stuck to my eye like ... lenses do not require the same level of care or consideration as a standard contact lens because ...

  15. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... colored contact lenses to enhance their costumes. From blood-drenched vampire eyes to glow-in-the-dark ... properly fitted may scratch the eye or cause blood vessels to grow into the cornea. Even if ...

  16. Caffeine increases the velocity of rapid eye movements in unfatigued humans.

    Science.gov (United States)

    Connell, Charlotte J W; Thompson, Benjamin; Turuwhenua, Jason; Hess, Robert F; Gant, Nicholas

    2017-08-01

    Caffeine is a widely used dietary stimulant that can reverse the effects of fatigue on cognitive, motor and oculomotor function. However, few studies have examined the effect of caffeine on the oculomotor system when homeostasis has not been disrupted by physical fatigue. This study examined the influence of a moderate dose of caffeine on oculomotor control and visual perception in participants who were not fatigued. Within a placebo-controlled crossover design, 13 healthy adults ingested caffeine (5 mg·kg -1 body mass) and were tested over 3 h. Eye movements, including saccades, smooth pursuit and optokinetic nystagmus, were measured using infrared oculography. Caffeine was associated with higher peak saccade velocities (472 ± 60° s -1 ) compared to placebo (455 ± 62° s -1 ). Quick phases of optokinetic nystagmus were also significantly faster with caffeine, whereas pursuit eye movements were unchanged. Non-oculomotor perceptual tasks (global motion and global orientation processing) were unaffected by caffeine. These results show that oculomotor control is modulated by a moderate dose of caffeine in unfatigued humans. These effects are detectable in the kinematics of rapid eye movements, whereas pursuit eye movements and visual perception are unaffected. Oculomotor functions may be sensitive to changes in central catecholamines mediated via caffeine's action as an adenosine antagonist, even when participants are not fatigued.

  17. Intraocular Telescopic System Design: Optical and Visual Simulation in a Human Eye Model

    Directory of Open Access Journals (Sweden)

    Georgios Zoulinakis

    2017-01-01

    Full Text Available Purpose. To design an intraocular telescopic system (ITS for magnifying retinal image and to simulate its optical and visual performance after implantation in a human eye model. Methods. Design and simulation were carried out with a ray-tracing and optical design software. Two different ITS were designed, and their visual performance was simulated using the Liou-Brennan eye model. The difference between the ITS was their lenses’ placement in the eye model and their powers. Ray tracing in both centered and decentered situations was carried out for both ITS while visual Strehl ratio (VSOTF was computed using custom-made MATLAB code. Results. The results show that between 0.4 and 0.8 mm of decentration, the VSOTF does not change much either for far or near target distances. The image projection for these decentrations is in the parafoveal zone, and the quality of the image projected is quite similar. Conclusion. Both systems display similar quality while they differ in size; therefore, the choice between them would need to take into account specific parameters from the patient’s eye. Quality does not change too much between 0.4 and 0.8 mm of decentration for either system which gives flexibility to the clinician to adjust decentration to avoid areas of retinal damage.

  18. Simplifying numerical ray tracing for two-dimensional non circularly symmetric models of the human eye.

    Science.gov (United States)

    Jesus, Danilo A; Iskander, D Robert

    2015-12-01

    Ray tracing is a powerful technique to understand the light behavior through an intricate optical system such as that of a human eye. The prediction of visual acuity can be achieved through characteristics of an optical system such as the geometrical point spread function. In general, its precision depends on the number of discrete rays and the accurate surface representation of each eye's components. Recently, a method that simplifies calculation of the geometrical point spread function has been proposed for circularly symmetric systems [Appl. Opt.53, 4784 (2014)]. An extension of this method to 2D noncircularly symmetric systems is proposed. In this method, a two-dimensional ray tracing procedure for an arbitrary number of surfaces and arbitrary surface shapes has been developed where surfaces, rays, and refractive indices are all represented in functional forms being approximated by Chebyshev polynomials. The Liou and Brennan anatomically accurate eye model has been adapted and used for evaluating the method. Further, real measurements of the anterior corneal surface of normal, astigmatic, and keratoconic eyes were substituted for the first surface in the model. The results have shown that performing ray tracing, utilizing the two-dimensional Chebyshev function approximation, is possible for noncircularly symmetric models, and that such calculation can be performed with a newly created Chebfun toolbox.

  19. Intraocular Telescopic System Design: Optical and Visual Simulation in a Human Eye Model.

    Science.gov (United States)

    Zoulinakis, Georgios; Ferrer-Blasco, Teresa

    2017-01-01

    Purpose. To design an intraocular telescopic system (ITS) for magnifying retinal image and to simulate its optical and visual performance after implantation in a human eye model. Methods. Design and simulation were carried out with a ray-tracing and optical design software. Two different ITS were designed, and their visual performance was simulated using the Liou-Brennan eye model. The difference between the ITS was their lenses' placement in the eye model and their powers. Ray tracing in both centered and decentered situations was carried out for both ITS while visual Strehl ratio (VSOTF) was computed using custom-made MATLAB code. Results. The results show that between 0.4 and 0.8 mm of decentration, the VSOTF does not change much either for far or near target distances. The image projection for these decentrations is in the parafoveal zone, and the quality of the image projected is quite similar. Conclusion. Both systems display similar quality while they differ in size; therefore, the choice between them would need to take into account specific parameters from the patient's eye. Quality does not change too much between 0.4 and 0.8 mm of decentration for either system which gives flexibility to the clinician to adjust decentration to avoid areas of retinal damage.

  20. About the Eye

    Medline Plus

    Full Text Available ... search for current job openings visit HHS USAJobs Home >> NEI for Kids >> About the Eye Listen All ... much as it does on your eyes. NEI Home Contact Us A-Z Site Map NEI on ...

  1. About the Eye

    Medline Plus

    Full Text Available ... search for current job openings visit HHS USAJobs Home » NEI for Kids » About the Eye Listen All ... much as it does on your eyes. NEI Home Contact Us A-Z Site Map NEI on ...

  2. Empirical Determination of Efficient Sensing Frequencies for Magnetometer-Based Continuous Human Contact Monitoring

    Directory of Open Access Journals (Sweden)

    Seungho Kuk

    2018-04-01

    Full Text Available The high linear correlation between the smartphone magnetometer readings in close proximity can be exploited for physical human contact detection, which could be useful for such applications as infectious disease contact tracing or social behavior monitoring. Alternative approaches using other capabilities in smartphones have aspects that do not fit well with the human contact detection. Using Wi-Fi or cellular fingerprints have larger localization errors than close human contact distances. Bluetooth beacons could reveal the identity of the transmitter, threatening the privacy of the user. Also, using sensors such as GPS does not work for indoor contacts. However, the magnetometer correlation check works best in human contact distances that matter in infectious disease transmissions or social interactions. The omni-present geomagnetism makes it work both indoors and outdoors, and the measured magnetometer values do not easily reveal the identity and the location of the smartphone. One issue with the magnetometer-based contact detection, however, is the energy consumption. Since the contacts can take place anytime, the magnetometer sensing and recording should be running continuously. Therefore, how we address the energy requirement for the extended and continuous operation can decide the viability of the whole idea. However, then, we note that almost all existing magnetometer-based applications such as indoor location and navigation have used high sensing frequencies, ranging from 10 Hz to 200 Hz. At these frequencies, we measure that the time to complete battery drain in a typical smartphone is shortened by three to twelve hours. The heavy toll raises the question as to whether the magnetometer-based contact detection can avoid such high sensing rates while not losing the contact detection accuracy. In order to answer the question, we conduct a measurement-based study using independently produced magnetometer traces from three different

  3. Empirical Determination of Efficient Sensing Frequencies for Magnetometer-Based Continuous Human Contact Monitoring.

    Science.gov (United States)

    Kuk, Seungho; Kim, Junha; Park, Yongtae; Kim, Hyogon

    2018-04-27

    The high linear correlation between the smartphone magnetometer readings in close proximity can be exploited for physical human contact detection, which could be useful for such applications as infectious disease contact tracing or social behavior monitoring. Alternative approaches using other capabilities in smartphones have aspects that do not fit well with the human contact detection. Using Wi-Fi or cellular fingerprints have larger localization errors than close human contact distances. Bluetooth beacons could reveal the identity of the transmitter, threatening the privacy of the user. Also, using sensors such as GPS does not work for indoor contacts. However, the magnetometer correlation check works best in human contact distances that matter in infectious disease transmissions or social interactions. The omni-present geomagnetism makes it work both indoors and outdoors, and the measured magnetometer values do not easily reveal the identity and the location of the smartphone. One issue with the magnetometer-based contact detection, however, is the energy consumption. Since the contacts can take place anytime, the magnetometer sensing and recording should be running continuously. Therefore, how we address the energy requirement for the extended and continuous operation can decide the viability of the whole idea. However, then, we note that almost all existing magnetometer-based applications such as indoor location and navigation have used high sensing frequencies, ranging from 10 Hz to 200 Hz. At these frequencies, we measure that the time to complete battery drain in a typical smartphone is shortened by three to twelve hours. The heavy toll raises the question as to whether the magnetometer-based contact detection can avoid such high sensing rates while not losing the contact detection accuracy. In order to answer the question, we conduct a measurement-based study using independently produced magnetometer traces from three different countries. Specifically, we

  4. Modelling temporal networks of human face-to-face contacts with public activity and individual reachability

    Science.gov (United States)

    Zhang, Yi-Qing; Cui, Jing; Zhang, Shu-Min; Zhang, Qi; Li, Xiang

    2016-02-01

    Modelling temporal networks of human face-to-face contacts is vital both for understanding the spread of airborne pathogens and word-of-mouth spreading of information. Although many efforts have been devoted to model these temporal networks, there are still two important social features, public activity and individual reachability, have been ignored in these models. Here we present a simple model that captures these two features and other typical properties of empirical face-to-face contact networks. The model describes agents which are characterized by an attractiveness to slow down the motion of nearby people, have event-triggered active probability and perform an activity-dependent biased random walk in a square box with periodic boundary. The model quantitatively reproduces two empirical temporal networks of human face-to-face contacts which are testified by their network properties and the epidemic spread dynamics on them.

  5. A direct contact between astrocyte and vitreous body is possible in the rabbit eye due to discontinuities in the basement membrane of the retinal inner limiting membrane

    Directory of Open Access Journals (Sweden)

    A. Haddad

    2003-02-01

    Full Text Available Different from most mammalian species, the optic nerve of the rabbit eye is initially formed inside the retina where myelination of the axons of the ganglion cells starts and vascularization occurs. Astrocytes are confined to these regions. The aforementioned nerve fibers known as medullated nerve fibers form two bundles that may be identified with the naked eye. The blood vessels run on the inner surface of these nerve fiber bundles (epivascularization and, accordingly, the accompanying astrocytes lie mostly facing the vitreous body from which they are separated only by the inner limiting membrane of the retina. The arrangement of the astrocytes around blood vessels leads to the formation of structures known as glial tufts. Fragments (N = 3 or whole pieces (N = 3 of the medullated nerve fiber region of three-month-old male rabbits (Orictolagus cuniculus were fixed in glutaraldehyde followed by osmium tetroxide, and their thin sections were examined with a transmission electron microscope. Randomly located discontinuities (up to a few micrometers long of the basement membrane of the inner limiting membrane of the retina were observed in the glial tufts. As a consequence, a direct contact between the astrocyte plasma membrane and vitreous elements was demonstrated, making possible functional interactions such as macromolecular exchanges between this glial cell type and the components of the vitreous body.

  6. Numerical modeling of heat and mass transfer in the human eye under millimeter wave exposure.

    Science.gov (United States)

    Karampatzakis, Andreas; Samaras, Theodoros

    2013-05-01

    Human exposure to millimeter wave (MMW) radiation is expected to increase in the next several years. In this work, we present a thermal model of the human eye under MMW illumination. The model takes into account the fluid dynamics of the aqueous humor and predicts a frequency-dependent reversal of its flow that also depends on the incident power density. The calculated maximum fluid velocity in the anterior chamber and the temperature rise at the corneal apex are reported for frequencies from 40 to 100 GHz and different values of incident power density. Copyright © 2013 Wiley Periodicals, Inc.

  7. Friction of human skin against smooth and rough glass as a function of the contact pressure

    NARCIS (Netherlands)

    Derler, S.; Gerhardt, L.C.; Lenz, A.; Bertaux, E.; Hadad, M.

    2009-01-01

    The friction behaviour of human skin was studied by combining friction measurements using a tri-axial force plate with skin contact area measurements using a pressure sensitive film. Four subjects carried out friction measurement series, in which they rubbed the index finger pad and the edge of the

  8. Time-related contact angle measurements with human plasma on biomaterial surfaces

    NARCIS (Netherlands)

    Rakhorst, G; Van der Mei, HC; van Oeveren, W; Spijker, HT; Busscher, HJ

    Axisymmetric drop shape analysis by profile (ADSA-P) was used to assess in time contact angle changes of human plasma drops placed on four different biomaterials. Results were related with conventional blood compatibility measurements: albumin adsorption, fibrinogen adsorption and platelet adhesion.

  9. Evaluation of human skin tests for potential dermal irritant and contact sensitizing products: a position paper

    NARCIS (Netherlands)

    Loveren H van; Jong WH de; Garssen J; LPI

    1998-01-01

    Prediction of human cutaneous irritation and sensitization in view of hazard identification has primarily relied on the use of laboratory animals. Such studies in laboratory animals have been very instrumental in the detection of potential contact sensitizing agents. There are however many

  10. Learning robotic eye-arm-hand coordination from human demonstration: a coupled dynamical systems approach.

    Science.gov (United States)

    Lukic, Luka; Santos-Victor, José; Billard, Aude

    2014-04-01

    We investigate the role of obstacle avoidance in visually guided reaching and grasping movements. We report on a human study in which subjects performed prehensile motion with obstacle avoidance where the position of the obstacle was systematically varied across trials. These experiments suggest that reaching with obstacle avoidance is organized in a sequential manner, where the obstacle acts as an intermediary target. Furthermore, we demonstrate that the notion of workspace travelled by the hand is embedded explicitly in a forward planning scheme, which is actively involved in detecting obstacles on the way when performing reaching. We find that the gaze proactively coordinates the pattern of eye-arm motion during obstacle avoidance. This study provides also a quantitative assessment of the coupling between the eye-arm-hand motion. We show that the coupling follows regular phase dependencies and is unaltered during obstacle avoidance. These observations provide a basis for the design of a computational model. Our controller extends the coupled dynamical systems framework and provides fast and synchronous control of the eyes, the arm and the hand within a single and compact framework, mimicking similar control system found in humans. We validate our model for visuomotor control of a humanoid robot.

  11. DNA methyl transferases are differentially expressed in the human anterior eye segment.

    Science.gov (United States)

    Bonnin, Nicolas; Belville, Corinne; Chiambaretta, Frédéric; Sapin, Vincent; Blanchon, Loïc

    2014-08-01

    DNA methylation is an epigenetic mark involved in the control of genes expression. Abnormal epigenetic events have been reported in human pathologies but weakly documented in eye diseases. The purpose of this study was to establish DNMT mRNA and protein expression levels in the anterior eye segment tissues and their related (primary or immortalized) cell cultures as a first step towards future in vivo and in vitro methylomic studies. Total mRNA was extracted from human cornea, conjunctiva, anterior lens capsule, trabeculum and related cell cultures (cornea epithelial, trabecular meshwork, keratocytes for primary cells; and HCE, Chang, B-3 for immortalized cells). cDNA was quantified by real-time PCR using specific primers for DNMT1, 2, 3A, 3B and 3L. Immunolocalization assays were carried out on human cornea using specific primary antibodies for DNMT1, 2 and 3A, 3B and 3L. All DNMT transcripts were detected in human cornea, conjunctiva, anterior lens capsule, trabeculum and related cells but showed statistically different expression patterns between tissues and cells. DNMT2 protein presented a specific and singular expression pattern in corneal endothelium. This study produced the first inventory of the expression patterns of DNMTs in human adult anterior eye segment. Our research highlights that DNA methylation cannot be ruled out as a way to bring new insights into well-known ocular diseases. In addition, future DNA methylation studies using various cells as experimental models need to be conducted with attention to approach the results analysis from a global tissue perspective. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  12. Diabetes-associated dry eye syndrome in a new humanized transgenic model of type 1 diabetes.

    Science.gov (United States)

    Imam, Shahnawaz; Elagin, Raya B; Jaume, Juan Carlos

    2013-01-01

    Patients with Type 1 Diabetes (T1D) are at high risk of developing lacrimal gland dysfunction. We have developed a new model of human T1D using double-transgenic mice carrying HLA-DQ8 diabetes-susceptibility haplotype instead of mouse MHC-class II and expressing the human beta cell autoantigen Glutamic Acid Decarboxylase in pancreatic beta cells. We report here the development of dry eye syndrome (DES) after diabetes induction in our humanized transgenic model. Double-transgenic mice were immunized with DNA encoding human GAD65, either naked or in adenoviral vectors, to induce T1D. Mice monitored for development of diabetes developed lacrimal gland dysfunction. Animals developed lacrimal gland disease (classically associated with diabetes in Non Obese Diabetic [NOD] mice and with T1D in humans) as they developed glucose intolerance and diabetes. Animals manifested obvious clinical signs of dry eye syndrome (DES), from corneal erosions to severe keratitis. Histological studies of peri-bulbar areas revealed lymphocytic infiltration of glandular structures. Indeed, infiltrative lesions were observed in lacrimal/Harderian glands within weeks following development of glucose intolerance. Lesions ranged from focal lymphocytic infiltration to complete acinar destruction. We observed a correlation between the severity of the pancreatic infiltration and the severity of the ocular disease. Our results demonstrate development of DES in association with antigen-specific insulitis and diabetes following immunization with clinically relevant human autoantigen concomitantly expressed in pancreatic beta cells of diabetes-susceptible mice. As in the NOD mouse model and as in human T1D, our animals developed diabetes-associated DES. This specific finding stresses the relevance of our model for studying these human diseases. We believe our model will facilitate studies to prevent/treat diabetes-associated DES as well as human diabetes.

  13. EyeGENE

    Data.gov (United States)

    U.S. Department of Health & Human Services — The eyeGENE® Biorepository and corresponding Database contain family history and clinical eye exam data from subjects enrolled in eyeGENE® Program coupled to...

  14. Vertical eye position-dependence of the human vestibuloocular reflex during passive and active yaw head rotations.

    Science.gov (United States)

    Thurtell, M J; Black, R A; Halmagyi, G M; Curthoys, I S; Aw, S T

    1999-05-01

    Vertical eye position-dependence of the human vestibuloocular reflex during passive and active yaw head rotations. The effect of vertical eye-in-head position on the compensatory eye rotation response to passive and active high acceleration yaw head rotations was examined in eight normal human subjects. The stimuli consisted of brief, low amplitude (15-25 degrees ), high acceleration (4,000-6,000 degrees /s2) yaw head rotations with respect to the trunk (peak velocity was 150-350 degrees /s). Eye and head rotations were recorded in three-dimensional space using the magnetic search coil technique. The input-output kinematics of the three-dimensional vestibuloocular reflex (VOR) were assessed by finding the difference between the inverted eye velocity vector and the head velocity vector (both referenced to a head-fixed coordinate system) as a time series. During passive head impulses, the head and eye velocity axes aligned well with each other for the first 47 ms after the onset of the stimulus, regardless of vertical eye-in-head position. After the initial 47-ms period, the degree of alignment of the eye and head velocity axes was modulated by vertical eye-in-head position. When fixation was on a target 20 degrees up, the eye and head velocity axes remained well aligned with each other. However, when fixation was on targets at 0 and 20 degrees down, the eye velocity axis tilted forward relative to the head velocity axis. During active head impulses, the axis tilt became apparent within 5 ms of the onset of the stimulus. When fixation was on a target at 0 degrees, the velocity axes remained well aligned with each other. When fixation was on a target 20 degrees up, the eye velocity axis tilted backward, when fixation was on a target 20 degrees down, the eye velocity axis tilted forward. The findings show that the VOR compensates very well for head motion in the early part of the response to unpredictable high acceleration stimuli-the eye position- dependence of the

  15. The effects of high-Dk rigid contact lens center thickness, material permeability, and blinking on the oxygen uptake of the human cornea.

    Science.gov (United States)

    Gardner, Hope Patterson; Fink, Barbara A; Mitchell, Lynn G; Hill, Richard M

    2005-06-01

    The human corneal oxygen uptake responses associated with the static (nonblinking) and dynamic (blinking) wear of five rigid gas-permeable materials with high oxygen permeabilities were determined for three different center thicknesses and compared with the responses for the normal open eye and severe hypoxic stress (static wear of polymethylmethacrylate). Corneal oxygen uptake rates were measured with a Clark-type polarographic electrode during two sessions with each of 10 human subjects. Measurements were made on the right eye for the normal open eye (air) and after 5 minutes of static and dynamic wear of polymethylmethacrylate and five rigid gas-permeable contact lens materials: Fluoroperm 92 (paflufocon A, Dk = 92), Fluoroperm 151 (paflufocon D, Dk = 151), 1992 Menicon SF-P (melafocon A, Dk = 102), 1995 Menicon SF-P (melafocon A, Dk = 159), and Menicon Z (tisilfocon A, Dk = 163-250). Lenses were manufactured in three different center thicknesses (0.12, 0.16, and 0.20 mm), with all other parameters remaining constant. Repeated-measures analysis of variance was used and included lens material (five levels), blinking condition (two levels), and lens thickness (three levels) as within-subject effects. Significant differences were found in corneal oxygen responses to lens material (p Dk rigid lens materials studied here, moderate changes in lens thickness or material permeability may result in modest differences in corneal hypoxic relief, whereas blinking results in no significant improvement to corneal oxygenation.

  16. In situ electric fields causing electro-stimulation from conductor contact of charged human

    International Nuclear Information System (INIS)

    Nagai, T.; Hirata, A.

    2010-01-01

    Contact currents flow from/into a human body when touching an object such as a metal structure with a different electric potential. These currents can stimulate muscle and peripheral nerves. In this context, computational analyses of in situ electric fields caused by the contact current have been performed, while their effectiveness for transient contact currents has not well been investigated. In the present study, using an anatomically based human model, a dispersive finite-difference time-domain model was utilised to computed transient contact current and in situ electric fields from a charged human. Computed in situ electric fields were highly localised in the hand. In order to obtain an insight into the relationship between in situ electric field and electro-stimulation, cell-maximum and 5-mm averaged in situ electric fields were computed and compared with strength-duration curves. The comparison suggests that both measures could be larger than thresholds derived from the strength- duration curves with parameters used in previous studies. (authors)

  17. Defining the Human Macula Transcriptome and Candidate Retinal Disease Genes UsingEyeSAGE

    Science.gov (United States)

    Rickman, Catherine Bowes; Ebright, Jessica N.; Zavodni, Zachary J.; Yu, Ling; Wang, Tianyuan; Daiger, Stephen P.; Wistow, Graeme; Boon, Kathy; Hauser, Michael A.

    2009-01-01

    Purpose To develop large-scale, high-throughput annotation of the human macula transcriptome and to identify and prioritize candidate genes for inherited retinal dystrophies, based on ocular-expression profiles using serial analysis of gene expression (SAGE). Methods Two human retina and two retinal pigment epithelium (RPE)/choroid SAGE libraries made from matched macula or midperipheral retina and adjacent RPE/choroid of morphologically normal 28- to 66-year-old donors and a human central retina longSAGE library made from 41- to 66-year-old donors were generated. Their transcription profiles were entered into a relational database, EyeSAGE, including microarray expression profiles of retina and publicly available normal human tissue SAGE libraries. EyeSAGE was used to identify retina- and RPE-specific and -associated genes, and candidate genes for retina and RPE disease loci. Differential and/or cell-type specific expression was validated by quantitative and single-cell RT-PCR. Results Cone photoreceptor-associated gene expression was elevated in the macula transcription profiles. Analysis of the longSAGE retina tags enhanced tag-to-gene mapping and revealed alternatively spliced genes. Analysis of candidate gene expression tables for the identified Bardet-Biedl syndrome disease gene (BBS5) in the BBS5 disease region table yielded BBS5 as the top candidate. Compelling candidates for inherited retina diseases were identified. Conclusions The EyeSAGE database, combining three different gene-profiling platforms including the authors’ multidonor-derived retina/RPE SAGE libraries and existing single-donor retina/RPE libraries, is a powerful resource for definition of the retina and RPE transcriptomes. It can be used to identify retina-specific genes, including alternatively spliced transcripts and to prioritize candidate genes within mapped retinal disease regions. PMID:16723438

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Cleveland. "This is far from the truth." Real People, Real Problems with Colored Contact Lenses Julian: Teenager ... about the members of the eye-care team . Consumer warning about the improper use of colored contact ...

  19. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... new application of artificial intelligence shows whether a patient’s eyes point to high blood pressure or risk ...

  20. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Costume Contacts May Contain Chemicals Harmful to Eyes Four Ways Over-the-Counter Costume Contact Lenses Can ... was in severe pain and on medication for four weeks, and couldn't see well enough to ...

  1. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Hazard: The Hidden Dangers of Buying Decorative Contact Lenses Without a Prescription Leer en Español: Peligros asociados ... truth." Real People, Real Problems with Colored Contact Lenses Julian: Teenager Blinded In One Eye By Non- ...

  2. Colored Contact Lens Dangers

    Science.gov (United States)

    ... Hazard: The Hidden Dangers of Buying Decorative Contact Lenses Without a Prescription Leer en Español: Peligros asociados ... truth." Real People, Real Problems with Colored Contact Lenses Julian: Teenager Blinded In One Eye By Non- ...

  3. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Cleveland. "This is far from the truth." Real People, Real Problems with Colored Contact Lenses Julian: Teenager ... the lenses. Never share contact lenses with another person. Get follow up exams with your eye care ...

  4. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... like a suction cup." Halloween is a popular time for people to use colored contact lenses to ... wear costume contact lenses for Halloween or any time of year, follow these guidelines: Get an eye ...

  5. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... glow-in-the-dark lizard lenses, costume contacts can certainly add a spooky, eye-popping touch. But ... consideration as a standard contact lens because they can be purchased over-the-counter or on the ...

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... the United States. All contact lenses are medical devices that require a prescription and proper fitting by an eye-care professional. Retailers that sell contacts without a ...

  7. Lens artifacts in human fetal eyes - the challenge of interpreting the histomorphology of human fetal lenses.

    Science.gov (United States)

    Herwig, Martina C; Müller, Annette M; Klarmann-Schulz, Ute; Holz, Frank G; Loeffler, Karin U

    2014-01-01

    Evaluation of the lens, including cataractous changes, is often of paramount importance in the classification of fetal syndromes or forensic questions. On histology, the crystalline lens is - especially in fetal and infant eyes - an organ susceptible to numerous artifacts. Thus, the aim of our study was to study various factors (including fixatives) that might have an impact on lens histomorphology. Twenty eyes from ten fetuses (formalin fixation: n = 10, glutaraldehyde fixation: n = 10), matched for gestational age and abortion (spontaneous vs. induced), were investigated macroscopically and by light microscopy. Sections were stained with routine hematoxylin & eosin (H&E), and periodic acid schiff (PAS). The age of the fetal eyes ranged from 15 to 36 weeks of gestation. Lens artifacts were analyzed and compared to fetal and adult lenses with definitive cataractous changes. In addition, 34 eyes from 27 fetuses with trisomy 21 were investigated for lens changes. All lenses showed artifacts of varying extent, in particular globules, vacuoles, clefts, anterior/posterior capsular separation, subcapsular proteinaceous material, fragmentation of the lens capsule/epithelium, and a posterior umbilication. Glutaraldehyde-fixed lenses displayed less artifacts compared to those fixed in formalin. Slight differences in the appearance of artifacts were found dependent on the fixative (formaldehyde vs glutaraldehyde) and the kind of abortion (iatrogenous vs spontaneous). The gestational age did not have a significant influence on the type and extent of lens artifacts. The lenses from fetuses with trisomy 21 displayed similar lens artifacts with no specific findings. Alterations in fetal lens morphology are extremely frequent and variable. These artifacts have to be carefully taken into account when interpreting post-mortem findings. Thus, the postmortem diagnosis of a fetal cataract should be made with great caution, and should include, in adherence to our proposed

  8. Human exposure to trace elements through the skin by direct contact with clothing: Risk assessment

    Energy Technology Data Exchange (ETDEWEB)

    Rovira, Joaquim [Laboratory of Toxicology and Environmental Health, School of Medicine, IISPV, Universitat Rovira i Virgili, Sant Llorenç 21, 43201 Reus, Catalonia (Spain); Environmental Engineering Laboratory, Departament d' Enginyeria Quimica, Universitat Rovira i Virgili, Av. Països Catalans 26, 43007 Tarragona, Catalonia (Spain); Nadal, Martí [Laboratory of Toxicology and Environmental Health, School of Medicine, IISPV, Universitat Rovira i Virgili, Sant Llorenç 21, 43201 Reus, Catalonia (Spain); Schuhmacher, Marta [Laboratory of Toxicology and Environmental Health, School of Medicine, IISPV, Universitat Rovira i Virgili, Sant Llorenç 21, 43201 Reus, Catalonia (Spain); Environmental Engineering Laboratory, Departament d' Enginyeria Quimica, Universitat Rovira i Virgili, Av. Països Catalans 26, 43007 Tarragona, Catalonia (Spain); Domingo, José L., E-mail: joseluis.domingo@urv.cat [Laboratory of Toxicology and Environmental Health, School of Medicine, IISPV, Universitat Rovira i Virgili, Sant Llorenç 21, 43201 Reus, Catalonia (Spain)

    2015-07-15

    Metals in textile products and clothing are used for many purposes, such as metal complex dyes, pigments, mordant, catalyst in synthetic fabrics manufacture, synergists of flame retardants, antimicrobials, or as water repellents and odour-preventive agents. When present in textile materials, heavy metals may mean a potential danger to human health. In the present study, the concentrations of a number of elements (Al, As, B, Ba, Be, Bi, Cd, Co, Cr, Cu, Fe, Hg, Mg, Mn, Mo, Ni, Pb, Sb, Sc, Se, Sm, Sn, Sr, Tl, V, and Zn) were determined in skin-contact clothes. Analysed clothes were made of different materials, colours, and brands. Interestingly, we found high levels of Cr in polyamide dark clothes (605 mg/kg), high Sb concentrations in polyester clothes (141 mg/kg), and great Cu levels in some green cotton fabrics (around 280 mg/kg). Dermal contact exposure and human health risks for adult males, adult females, and for <1-year-old children were assessed. Non-carcinogenic and carcinogenic risks were below safe (HQ<1) and acceptable (<10{sup −6}) limits, respectively, according to international standards. However, for Sb, non-carcinogenic risk was above 10% of the safety limit (HQ>0.1) for dermal contact with clothes. - Highlights: • We determined in skin-contact clothes the concentrations of a number of metals. • Dermal contact exposure and health risks for adults and for 1-year-old children were assessed. • Carcinogenic risks were considered as acceptable (<10{sup −6}). • For non-carcinogenic risks, only Sb exceeded a 10% of the HQ for dermal contact with clothes.

  9. Human exposure to trace elements through the skin by direct contact with clothing: Risk assessment

    International Nuclear Information System (INIS)

    Rovira, Joaquim; Nadal, Martí; Schuhmacher, Marta; Domingo, José L.

    2015-01-01

    Metals in textile products and clothing are used for many purposes, such as metal complex dyes, pigments, mordant, catalyst in synthetic fabrics manufacture, synergists of flame retardants, antimicrobials, or as water repellents and odour-preventive agents. When present in textile materials, heavy metals may mean a potential danger to human health. In the present study, the concentrations of a number of elements (Al, As, B, Ba, Be, Bi, Cd, Co, Cr, Cu, Fe, Hg, Mg, Mn, Mo, Ni, Pb, Sb, Sc, Se, Sm, Sn, Sr, Tl, V, and Zn) were determined in skin-contact clothes. Analysed clothes were made of different materials, colours, and brands. Interestingly, we found high levels of Cr in polyamide dark clothes (605 mg/kg), high Sb concentrations in polyester clothes (141 mg/kg), and great Cu levels in some green cotton fabrics (around 280 mg/kg). Dermal contact exposure and human health risks for adult males, adult females, and for <1-year-old children were assessed. Non-carcinogenic and carcinogenic risks were below safe (HQ<1) and acceptable (<10 −6 ) limits, respectively, according to international standards. However, for Sb, non-carcinogenic risk was above 10% of the safety limit (HQ>0.1) for dermal contact with clothes. - Highlights: • We determined in skin-contact clothes the concentrations of a number of metals. • Dermal contact exposure and health risks for adults and for 1-year-old children were assessed. • Carcinogenic risks were considered as acceptable (<10 −6 ). • For non-carcinogenic risks, only Sb exceeded a 10% of the HQ for dermal contact with clothes

  10. Postural And Eye-Positional Effects On Human Biting Force: An Experimental Study

    Directory of Open Access Journals (Sweden)

    Altay Tabancacı

    2012-06-01

    Full Text Available Muscle groups affected on biting force are called temporal muscle as a major and masseter muscle as a minor. According to the human posture stability, forces of these muscles vary with the force directions. In this case, experimental investigation is strictly important such that biting force under different postural and eye- positional situations is changed. In this study, seven-male and seven-female within the age-range of 17-24 are considered corresponding to having with restorated molar tooth and without that type of tooth. With the help of specially designed biting fork, different posture- and eye-positions are investigated for experimental biting force analysis. Changes in eye-positions are not indicated significant difference for all postural positions. On one hand, it is obtained that biting force of no-filling tooth in men becomes maximum if facial muscles give full effort to biting. On the other hand, effect of facial muscles for women is not clearly noticed depending on the postural differences.

  11. FDTD computation of human eye exposure to ultra-wideband electromagnetic pulses

    Energy Technology Data Exchange (ETDEWEB)

    Simicevic, Neven [Center for Applied Physics Studies, Louisiana Tech University, Ruston, LA 71272 (United States)], E-mail: neven@phys.latech.edu

    2008-03-21

    With an increase in the application of ultra-wideband (UWB) electromagnetic pulses in the communications industry, radar, biotechnology and medicine, comes an interest in UWB exposure safety standards. Despite an increase of the scientific research on bioeffects of exposure to non-ionizing UWB pulses, characterization of those effects is far from complete. A numerical computational approach, such as a finite-difference time domain (FDTD) method, is required to visualize and understand the complexity of broadband electromagnetic interactions. The FDTD method has almost no limits in the description of the geometrical and dispersive properties of the simulated material, it is numerically robust and appropriate for current computer technology. In this paper, a complete calculation of exposure of the human eye to UWB electromagnetic pulses in the frequency range of 3.1-10.6, 22-29 and 57-64 GHz is performed. Computation in this frequency range required a geometrical resolution of the eye of 0.1 mm and an arbitrary precision in the description of its dielectric properties in terms of the Debye model. New results show that the interaction of UWB pulses with the eye tissues exhibits the same properties as the interaction of the continuous electromagnetic waves (CWs) with the frequencies from the pulse's frequency spectrum. It is also shown that under the same exposure conditions the exposure to UWB pulses is from one to many orders of magnitude safer than the exposure to CW.

  12. FDTD computation of human eye exposure to ultra-wideband electromagnetic pulses.

    Science.gov (United States)

    Simicevic, Neven

    2008-03-21

    With an increase in the application of ultra-wideband (UWB) electromagnetic pulses in the communications industry, radar, biotechnology and medicine, comes an interest in UWB exposure safety standards. Despite an increase of the scientific research on bioeffects of exposure to non-ionizing UWB pulses, characterization of those effects is far from complete. A numerical computational approach, such as a finite-difference time domain (FDTD) method, is required to visualize and understand the complexity of broadband electromagnetic interactions. The FDTD method has almost no limits in the description of the geometrical and dispersive properties of the simulated material, it is numerically robust and appropriate for current computer technology. In this paper, a complete calculation of exposure of the human eye to UWB electromagnetic pulses in the frequency range of 3.1-10.6, 22-29 and 57-64 GHz is performed. Computation in this frequency range required a geometrical resolution of the eye of 0.1 mm and an arbitrary precision in the description of its dielectric properties in terms of the Debye model. New results show that the interaction of UWB pulses with the eye tissues exhibits the same properties as the interaction of the continuous electromagnetic waves (CWs) with the frequencies from the pulse's frequency spectrum. It is also shown that under the same exposure conditions the exposure to UWB pulses is from one to many orders of magnitude safer than the exposure to CW.

  13. FDTD computation of human eye exposure to ultra-wideband electromagnetic pulses

    International Nuclear Information System (INIS)

    Simicevic, Neven

    2008-01-01

    With an increase in the application of ultra-wideband (UWB) electromagnetic pulses in the communications industry, radar, biotechnology and medicine, comes an interest in UWB exposure safety standards. Despite an increase of the scientific research on bioeffects of exposure to non-ionizing UWB pulses, characterization of those effects is far from complete. A numerical computational approach, such as a finite-difference time domain (FDTD) method, is required to visualize and understand the complexity of broadband electromagnetic interactions. The FDTD method has almost no limits in the description of the geometrical and dispersive properties of the simulated material, it is numerically robust and appropriate for current computer technology. In this paper, a complete calculation of exposure of the human eye to UWB electromagnetic pulses in the frequency range of 3.1-10.6, 22-29 and 57-64 GHz is performed. Computation in this frequency range required a geometrical resolution of the eye of 0.1 mm and an arbitrary precision in the description of its dielectric properties in terms of the Debye model. New results show that the interaction of UWB pulses with the eye tissues exhibits the same properties as the interaction of the continuous electromagnetic waves (CWs) with the frequencies from the pulse's frequency spectrum. It is also shown that under the same exposure conditions the exposure to UWB pulses is from one to many orders of magnitude safer than the exposure to CW

  14. Optics of the human cornea influence the accuracy of stereo eye-tracking methods: a simulation study.

    Science.gov (United States)

    Barsingerhorn, A D; Boonstra, F N; Goossens, H H L M

    2017-02-01

    Current stereo eye-tracking methods model the cornea as a sphere with one refractive surface. However, the human cornea is slightly aspheric and has two refractive surfaces. Here we used ray-tracing and the Navarro eye-model to study how these optical properties affect the accuracy of different stereo eye-tracking methods. We found that pupil size, gaze direction and head position all influence the reconstruction of gaze. Resulting errors range between ± 1.0 degrees at best. This shows that stereo eye-tracking may be an option if reliable calibration is not possible, but the applied eye-model should account for the actual optics of the cornea.

  15. Surface topography and contact mechanics of dry and wet human skin

    Directory of Open Access Journals (Sweden)

    Alexander E. Kovalev

    2014-08-01

    Full Text Available The surface topography of the human wrist skin is studied by using optical and atomic force microscopy (AFM methods. By using these techniques the surface roughness power spectrum is obtained. The Persson contact mechanics theory is used to calculate the contact area for different magnifications, for the dry and wet skin. The measured friction coefficient between a glass ball and dry and wet skin can be explained assuming that a frictional shear stress σf ≈ 13 MPa and σf ≈ 5 MPa, respectively, act in the area of real contact during sliding. These frictional shear stresses are typical for sliding on surfaces of elastic bodies. The big increase in friction, which has been observed for glass sliding on wet skin as the skin dries up, can be explained as result of the increase in the contact area arising from the attraction of capillary bridges. Finally, we demonstrated that the real contact area can be properly defined only when a combination of both AFM and optical methods is used for power spectrum calculation.

  16. The Way Dogs (Canis familiaris Look at Human Emotional Faces Is Modulated by Oxytocin. An Eye-Tracking Study

    Directory of Open Access Journals (Sweden)

    Anna Kis

    2017-10-01

    Full Text Available Dogs have been shown to excel in reading human social cues, including facial cues. In the present study we used eye-tracking technology to further study dogs’ face processing abilities. It was found that dogs discriminated between human facial regions in their spontaneous viewing pattern and looked most to the eye region independently of facial expression. Furthermore dogs played most attention to the first two images presented, afterwards their attention dramatically decreases; a finding that has methodological implications. Increasing evidence indicates that the oxytocin system is involved in dogs’ human-directed social competence, thus as a next step we investigated the effects of oxytocin on processing of human facial emotions. It was found that oxytocin decreases dogs’ looking to the human faces expressing angry emotional expression. More interestingly, however, after oxytocin pre-treatment dogs’ preferential gaze toward the eye region when processing happy human facial expressions disappears. These results provide the first evidence that oxytocin is involved in the regulation of human face processing in dogs. The present study is one of the few empirical investigations that explore eye gaze patterns in naïve and untrained pet dogs using a non-invasive eye-tracking technique and thus offers unique but largely untapped method for studying social cognition in dogs.

  17. Effects of intraocular lenses with different diopters on chromatic aberrations in human eye models.

    Science.gov (United States)

    Song, Hui; Yuan, Xiaoyong; Tang, Xin

    2016-01-11

    In this study, the effects of intraocular lenses (IOLs) with different diopters (D) on chromatic aberration were investigated in human eye models, and the influences of the central thickness of IOLs on chromatic aberration were compared. A Liou-Brennan-based IOL eye model was constructed using ZEMAX optical design software. Spherical IOLs with different diopters (AR40e, AMO Company, USA) were implanted; modulation transfer function (MTF) values at 3 mm of pupil diameter and from 0 to out-of-focus blur were collected and graphed. MTF values, measured at 555 nm of monochromatic light under each spatial frequency, were significantly higher than the values measured at 470 to 650 nm of polychromatic light. The influences of chromatic aberration on MTF values decreased with the increase in IOL diopter when the spatial frequency was ≤12 c/d, while increased effects were observed when the spatial frequency was ≥15 c/d. The MTF values of each IOL eye model were significantly lower than the MTF values of the Liou-Brennan eye models when measured at 555 nm of monochromatic light and at 470 to 650 nm of polychromatic light. The MTF values were also found to be increased with the increase in IOL diopter. With higher diopters of IOLs, the central thickness increased accordingly, which could have created increased chromatic aberration and decreased the retinal image quality. To improve the postoperative visual quality, IOLs with lower chromatic aberration should be selected for patients with short axial lengths.

  18. Femtosecond laser-induced cavitations in the lens of the human eye

    DEFF Research Database (Denmark)

    Kessel, Line; Nymand, Jose; Harbst, Michael

    2007-01-01

    attempted to define the cavitation threshold in the human lens in vitro using multiphoton effects base d on radiation from a femtosecond 800 nm Ti:Sapphire laser. Cavitations were observed from pulse energy densities exceeding 16 mJ/cm2, but only after several minutes of exposure and not as a result...... laser effects in the len s that have a potential for therapeutic application and treatment of eye dis ease though further studies are needed to shed light on the nature of the formation of delayed cavitations....

  19. Towards Quantum Experiments with Human Eyes as Detectors Based on Cloning via Stimulated Emission

    Science.gov (United States)

    Sekatski, Pavel; Brunner, Nicolas; Branciard, Cyril; Gisin, Nicolas; Simon, Christoph

    2009-09-01

    We show theoretically that a large Bell inequality violation can be obtained with human eyes as detectors, in a “micro-macro” experiment where one photon from an entangled pair is greatly amplified via stimulated emission. The violation is robust under photon loss. This leads to an apparent paradox, which we resolve by noting that the violation proves the existence of entanglement before the amplification. The same is true for the micro-macro experiments performed so far with conventional detectors. However, we also prove that there is genuine micro-macro entanglement even for high loss.

  20. Investigation of human body potential measured by a non-contact measuring system.

    Science.gov (United States)

    Ichikawa, Norimitsu

    2016-12-07

    A human body is occasionally electrified in a room. This charged object will be a source of electrostatic accidents, including the malfunction of electronic equipment. Hence, prevention of these accidents is required. Accidents occasionally occur, even though antistatic clothes and shoes are used. One of the causes for these accidents is that there is a lack of the preventive measures. This situation occurs when using, for example, unconductive wax. In this study, human body potential (voltage) is measured using a non-contact measuring system. An investigation of the human body's voltage when using this system is conducted. The result demonstrates that the voltage of a human body wearing antistatic clothes and shoes or light clothes and slippers exceeds a malfunctioning voltage of a microelectronics device when the body walks on floors. Thus, accidents may occur even if a human body wearing the antistatic clothes walks on flooring. These results will be useful in estimating determination whether electrostatic accidents occur or not.

  1. Evaluation of Eye Irritation Potential of Solid Substance with New 3D Reconstructed Human Cornea Model, MCTT HCE(TM).

    Science.gov (United States)

    Jang, Won-Hee; Jung, Kyoung-Mi; Yang, Hye-Ri; Lee, Miri; Jung, Haeng-Sun; Lee, Su-Hyon; Park, Miyoung; Lim, Kyung-Min

    2015-07-01

    The eye irritation potential of drug candidates or pharmaceutical ingredients should be evaluated if there is a possibility of ocular exposure. Traditionally, the ocular irritation has been evaluated by the rabbit Draize test. However, rabbit eyes are more sensitive to irritants than human eyes, therefore substantial level of false positives are unavoidable. To resolve this species difference, several three-dimensional human corneal epithelial (HCE) models have been developed as alternative eye irritation test methods. Recently, we introduced a new HCE model, MCTT HCE(TM) which is reconstructed with non-transformed human corneal cells from limbal tissues. Here, we examined if MCTT HCE(TM) can be employed to evaluate eye irritation potential of solid substances. Through optimization of washing method and exposure time, treatment time was established as 10 min and washing procedure was set up as 4 times of washing with 10 mL of PBS and shaking in 30 mL of PBS in a beaker. With the established eye irritation test protocol, 11 solid substances (5 non-irritants, 6 irritants) were evaluated which demonstrated an excellent predictive capacity (100% accuracy, 100% specificity and 100% sensitivity). We also compared the performance of our test method with rabbit Draize test results and in vitro cytotoxicity test with 2D human corneal epithelial cell lines.

  2. Molecular mechanism of ocular surface damage: application to an in vitro dry eye model on human corneal epithelium.

    Science.gov (United States)

    Meloni, Marisa; De Servi, Barbara; Marasco, Daniela; Del Prete, Salvatore

    2011-01-12

    The present study was concerned with the development of a new experimental model of dry eye using human reconstructed in vitro corneal epithelium (HCE). The model is based on the use of adapted culture conditions that induce relevant modifications at the cellular and molecular level thus mimicking dry eye. The HCE model was maintained in a controlled environmental setting (relative humidity eye. The evolution of the dry eye condition was assessed by histology, immunohistochemistry staining, scanning electron microscopy, and gene expression by using TaqMan gene assay technology (mucin-4 [MUC4], matrix metallopeptidase-9 [MMP9], tumor necrosis factor-α [TNF-α], and defensin β-2 [DEFB2). The effects of different commercially available tear substitutes on the induced dry eye condition were tested. This in vitro dry eye HCE model, that was well established within 24 h, has the characteristic features of a dry eye epithelium and could be satisfactorily used for preliminary assessment of the protective activity of some artificial tears. The transcriptional study of selected biomarkers showed an increase in MUC4, MMP9, TNF-α, and hBD-2 (DEFB2) gene expression. By using a dynamic approach, we were able to define a biomarker gene signature of dry eye-induced effects that could be predictive of corneal damage in vivo and to discriminate the efficacy among different commercial artificial tears.

  3. Gold nanoparticle-based brachytherapy enhancement in choroidal melanoma using a full Monte Carlo model of the human eye.

    Science.gov (United States)

    Asadi, Somayeh; Vaez-zadeh, Mehdi; Masoudi, S Farhad; Rahmani, Faezeh; Knaup, Courtney; Meigooni, Ali S

    2015-09-08

    The effects of gold nanoparticles (GNPs) in 125I brachytherapy dose enhancement on choroidal melanoma are examined using the Monte Carlo simulation technique. Usually, Monte Carlo ophthalmic brachytherapy dosimetry is performed in a water phantom. However, here, the compositions of human eye have been considered instead of water. Both human eye and water phantoms have been simulated with MCNP5 code. These simulations were performed for a fully loaded 16 mm COMS eye plaque containing 13 125I seeds. The dose delivered to the tumor and normal tissues have been calculated in both phantoms with and without GNPs. Normally, the radiation therapy of cancer patients is designed to deliver a required dose to the tumor while sparing the surrounding normal tissues. However, as the normal and cancerous cells absorbed dose in an almost identical fashion, the normal tissue absorbed radiation dose during the treatment time. The use of GNPs in combination with radiotherapy in the treatment of tumor decreases the absorbed dose by normal tissues. The results indicate that the dose to the tumor in an eyeball implanted with COMS plaque increases with increasing GNPs concentration inside the target. Therefore, the required irradiation time for the tumors in the eye is decreased by adding the GNPs prior to treatment. As a result, the dose to normal tissues decreases when the irradiation time is reduced. Furthermore, a comparison between the simulated data in an eye phantom made of water and eye phantom made of human eye composition, in the presence of GNPs, shows the significance of utilizing the composition of eye in ophthalmic brachytherapy dosimetry Also, defining the eye composition instead of water leads to more accurate calculations of GNPs radiation effects in ophthalmic brachytherapy dosimetry.

  4. Leptospirosis in animals and human contacts in Egypt: broad range surveillance

    Directory of Open Access Journals (Sweden)

    Ahmed Samir

    2015-06-01

    Full Text Available INTRODUCTION: Leptospirosis is a re-emerging zoonotic disease of humans and animals worldwide. The disease is caused by pathogenic species of the genus Leptospira. These organisms are maintained in nature via chronic renal infection of carrier animals, which excrete the organisms in their urine. Humans become infected through direct or indirect exposure to infected animals and their urine or through contact with contaminated water and soil. This study was conducted to investigate Leptospira infections as a re-emerging zoonosis that has been neglected in Egypt. METHODS: Samples from 1,250 animals (270 rats, 168 dogs, 625 cows, 26 buffaloes, 99 sheep, 14 horses, 26 donkeys and 22 camels, 175 human contacts and 45 water sources were collected from different governorates in Egypt. The samples were collected from different body sites and prepared for culture, PCR and the microscopic agglutination test (MAT. RESULTS: The isolation rates of Leptospira serovars were 6.9%, 11.3% and 1.1% for rats, dogs and cows, respectively, whereas the PCR results revealed respective detection rates of 24%, 11.3% and 1.1% for rats, dogs and cows. Neither the other examined animal species nor humans yielded positive results via these two techniques. Only six Leptospira serovars (Icterohaemorrhagiae, Pomona, Canicola, Grippotyphosa, Celledoni and Pyrogenes could be isolated from rats, dogs and cows. Moreover, the seroprevalence of leptospiral antibodies among the examined humans determined using MAT was 49.7%. CONCLUSIONS: The obtained results revealed that rats, dogs and cows were the most important animal reservoirs for leptospirosis in Egypt, and the high seroprevalence among human contacts highlights the public health implications of this neglected zoonosis.

  5. Does the foveal shape influence the image formation in human eyes?

    Science.gov (United States)

    Frey, Katharina; Zimmerling, Beatrice; Scheibe, Patrick; Rauscher, Franziska G.; Reichenbach, Andreas; Francke, Mike; Brunner, Robert

    2017-10-01

    In human eyes, the maximum visual acuity correlates locally with the fovea, a shallow depression in the retina. Previous examinations have been reduced to simple geometrical fovea models derived from postmortem preparations and considering only a few superficial ray propagation aspects. In the current study, an extended and realistic analysis of ray-optical simulations for a comprehensive anatomical realistic eye model for the anterior part and realistic aspherical human foveal topographical profiles deduced from in vivo optical coherence tomography (OCT) are presented, and the refractive index step at the transition from vitreous to retinal tissue is taken into account. The optical effect of a commonly shaped (averaged) and an extraordinarily shaped foveal pit were both compared to the analysis of an assumed pure spherical boundary layer. The influence of the aperture size, wavelength, and incident angle on the spot size and shape, as well as the axial focal and lateral centroid position is investigated, and a lateral displacement of about 2 μm and an axial shift of the best focal position of less than 4 μm are found. These findings indicate only small optical effects that are laterally in the range of inter-receptor distances and axially less than the photoreceptor outer segment dimension.

  6. Computational dosimetry for grounded and ungrounded human models due to contact current

    International Nuclear Information System (INIS)

    Chan, Kwok Hung; Hattori, Junya; Laakso, Ilkka; Hirata, Akimasa; Taki, Masao

    2013-01-01

    This study presents the computational dosimetry of contact currents for grounded and ungrounded human models. The uncertainty of the quasi-static (QS) approximation of the in situ electric field induced in a grounded/ungrounded human body due to the contact current is first estimated. Different scenarios of cylindrical and anatomical human body models are considered, and the results are compared with the full-wave analysis. In the QS analysis, the induced field in the grounded cylindrical model is calculated by the QS finite-difference time-domain (QS-FDTD) method, and compared with the analytical solution. Because no analytical solution is available for the grounded/ungrounded anatomical human body model, the results of the QS-FDTD method are then compared with those of the conventional FDTD method. The upper frequency limit for the QS approximation in the contact current dosimetry is found to be 3 MHz, with a relative local error of less than 10%. The error increases above this frequency, which can be attributed to the neglect of the displacement current. The QS or conventional FDTD method is used for the dosimetry of induced electric field and/or specific absorption rate (SAR) for a contact current injected into the index finger of a human body model in the frequency range from 10 Hz to 100 MHz. The in situ electric fields or SAR are compared with the basic restrictions in the international guidelines/standards. The maximum electric field or the 99th percentile value of the electric fields appear not only in the fat and muscle tissues of the finger, but also around the wrist, forearm, and the upper arm. Some discrepancies are observed between the basic restrictions for the electric field and SAR and the reference levels for the contact current, especially in the extremities. These discrepancies are shown by an equation that relates the current density, tissue conductivity, and induced electric field in the finger with a cross-sectional area of 1 cm 2 . (paper)

  7. [Contact glass tonometer].

    Science.gov (United States)

    Dekker, P W; Kanngiesser, H; Robert, Y C

    1996-05-01

    This paper presents a tonometer built into a contactlens, which allows to measure the eye-pressure and to perform ophthalmoscopy at the same time. Artificially induced changes of the eye-pressure and their influence on the visible fundus can now be checked simultaneously. The contactlens-tonometer (CGT) also is able to record continuously the pulse-curve, which can indicate any circulatory problem. So, the device is expected to give us additional diagnostic criteria of early glaucoma. Each ophthalmologyst in the field will be able to perform with this device a oculodynamometry in an easy way. By this it is possible to estimate the pressure-tolerance of the optic disk from glaucoma-patients. There have been taken some measurements on enucleated human eyes, comparing our device with a Statham-transducer in the vitreous. We found a good correlation. In a second step, we made measurements (65) on healthy volunteers, comparing the device with Perkins-Tonometry. We found a correlation (R = 0.58). The error of the measurements was about +/- 3 mm Hg. Considering both, the deviation of the Perkins-Tonometer with which our results were compared, and the fact of a good correlation (R = 0.999) in the study with the enucleated human eyes, we found that the contact-lens-tonometer measures the intraocular pressure exactly. In future studies, we want to analyze the dynamic component of the measurements.

  8. Differences in Dry Eye Questionnaire Symptoms in Two Different Modalities of Contact Lens Wear: Silicone-Hydrogel in Daily Wear Basis and Overnight Orthokeratology

    Directory of Open Access Journals (Sweden)

    Nery García-Porta

    2016-01-01

    Full Text Available Purpose. To compare the ocular surface symptoms and signs in an adult population of silicone-hydrogel (Si-Hy contact lens (CL wearers with another modality of CL wear, overnight orthokeratology (OK. Materials and Methods. This was a prospective and comparative study in which 31 myopic subjects were fitted with the same Si-Hy CL and 23 underwent OK treatment for 3 months. Dry eye questionnaire (DEQ was filled in at the beginning of the study and then after 15 days, 1 month, and 3 months using each CL modality. The tear quality was evaluated with noninvasive tear break-up time. Tear production was measured with Schirmer test. Tear samples were collected with Schirmer strips being frozen to analyze the dinucleotide diadenosine tetraphosphate (Ap4A concentration with High-Performance Liquid Chromatography (HPLC. Results. After refitting with ortho-k, a reduction in discomfort and dryness symptoms at the end of the day (p<0.05, χ2 was observed. No significant changes were observed in Ap4A concentration in any group. Bulbar redness, limbal redness, and conjunctival staining increased significantly in the Si-Hy group (p<0.05, Kruskal–Wallis test. Conclusion. Discomfort and dryness symptoms at the end of the day are lower in the OK CL group than in the Si-Hy CL group.

  9. Predictive Simulations of Neuromuscular Coordination and Joint-Contact Loading in Human Gait.

    Science.gov (United States)

    Lin, Yi-Chung; Walter, Jonathan P; Pandy, Marcus G

    2018-04-18

    We implemented direct collocation on a full-body neuromusculoskeletal model to calculate muscle forces, ground reaction forces and knee contact loading simultaneously for one cycle of human gait. A data-tracking collocation problem was solved for walking at the normal speed to establish the practicality of incorporating a 3D model of articular contact and a model of foot-ground interaction explicitly in a dynamic optimization simulation. The data-tracking solution then was used as an initial guess to solve predictive collocation problems, where novel patterns of movement were generated for walking at slow and fast speeds, independent of experimental data. The data-tracking solutions accurately reproduced joint motion, ground forces and knee contact loads measured for two total knee arthroplasty patients walking at their preferred speeds. RMS errors in joint kinematics were joint kinematics, ground forces, knee contact loads and muscle activation patterns measured for slow and fast walking. The results demonstrate the feasibility of performing computationally-efficient, predictive, dynamic optimization simulations of movement using full-body, muscle-actuated models with realistic representations of joint function.

  10. Intraocular distribution of melanin in human, monkey, rabbit, minipig and dog eyes.

    Science.gov (United States)

    Durairaj, Chandrasekar; Chastain, James E; Kompella, Uday B

    2012-05-01

    The purpose of this study was to quantify the melanin pigment content in sclera, choroid-RPE, and retina, three tissues encountered during transscleral drug delivery to the vitreous, in human, rabbit, monkey, minipig, and dog models. Strain differences were assessed in NZW × NZR F1 and Dutch belted rabbits and Yucatan and Gottingen minipigs. The choroid-RPE and retina tissues were divided into central (posterior pole area) and peripheral (away from posterior pole) regions while the sclera was analyzed without such division. Melanin content in the tissues was analyzed using a colorimetric assay. In all species the rank order for pigment content was: choroid-RPE >retina ≥ sclera, except in humans, where scleral melanin levels were higher than retina and central choroid. The melanin content in a given tissue differed between species. Further, while the peripheral tissue pigment levels tended to be generally higher compared to the central regions, these differences were significant in human in the case of choroid-RPE and in human, monkey, and dogs in the case of retina. Strain difference was observed only in the central choroid-RPE region of rabbits (NZW × NZR F1 >Dutch Belted). Species, strain, and regional differences exist in the melanin pigment content in the tissues of the posterior segment of the eye, with Gottingen minipig being closest to humans among the animals assessed. These differences in melanin content might contribute to differences in drug binding, delivery, and toxicity. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Measuring higher order optical aberrations of the human eye: techniques and applications

    Directory of Open Access Journals (Sweden)

    L. Alberto V. Carvalho

    2002-11-01

    Full Text Available In the present paper we discuss the development of "wave-front", an instrument for determining the lower and higher optical aberrations of the human eye. We also discuss the advantages that such instrumentation and techniques might bring to the ophthalmology professional of the 21st century. By shining a small light spot on the retina of subjects and observing the light that is reflected back from within the eye, we are able to quantitatively determine the amount of lower order aberrations (astigmatism, myopia, hyperopia and higher order aberrations (coma, spherical aberration, etc.. We have measured artificial eyes with calibrated ametropia ranging from +5 to -5 D, with and without 2 D astigmatism with axis at 45º and 90º. We used a device known as the Hartmann-Shack (HS sensor, originally developed for measuring the optical aberrations of optical instruments and general refracting surfaces in astronomical telescopes. The HS sensor sends information to a computer software for decomposition of wave-front aberrations into a set of Zernike polynomials. These polynomials have special mathematical properties and are more suitable in this case than the traditional Seidel polynomials. We have demonstrated that this technique is more precise than conventional autorefraction, with a root mean square error (RMSE of less than 0.1 µm for a 4-mm diameter pupil. In terms of dioptric power this represents an RMSE error of less than 0.04 D and 5º for the axis. This precision is sufficient for customized corneal ablations, among other applications.

  12. Human trafficking and health: a cross-sectional survey of NHS professionals’ contact with victims of human trafficking

    Science.gov (United States)

    Ross, Claire; Dimitrova, Stoyanka; Howard, Louise M; Dewey, Michael; Zimmerman, Cathy; Oram, Siân

    2015-01-01

    Objectives (1) To estimate the proportion of National Health Service (NHS) professionals who have come into contact with trafficked people and (2) to measure NHS professionals’ knowledge and confidence to respond to human trafficking. Design A cross-sectional survey. Setting Face-to-face mandatory child protection and/or vulnerable adults training sessions at 10 secondary healthcare provider organisations in England, and meetings of the UK College of Emergency Medicine. Participants 782/892 (84.4%) NHS professionals participated, including from emergency medicine, maternity, mental health, paediatrics and other clinical disciplines. Measures Self-completed questionnaire developed by an expert panel. Questionnaire asks about prior training and contact with potential victims of trafficking, perceived and actual human trafficking knowledge, confidence in responding to human trafficking, and interest in future human trafficking training. Results 13% participants reported previous contact with a patient they knew or suspected of having been trafficked; among maternity services professionals this was 20.4%. However, 86.8% (n=679) reported lacking knowledge of what questions to ask to identify potential victims and 78.3% (n=613) reported that they had insufficient training to assist trafficked people. 71% (n=556), 67.5% (n=528) and 53.4% (n=418) lacked confidence in making appropriate referrals for men, women and children, respectively, who had been trafficked. 95.3% (n=746) of respondents were unaware of the scale of human trafficking in the UK, and 76.5% (n=598) were unaware that calling the police could put patients in more danger. Psychometric analysis showed that subscales measuring perceived knowledge, actual knowledge and confidence to respond to human trafficking demonstrated good internal consistency (Cronbach's αs 0.93, 0.63 and 0.64, respectively) and internal correlations. Conclusions NHS professionals working in secondary care are in contact with potential

  13. Human trafficking and health: a cross-sectional survey of NHS professionals' contact with victims of human trafficking.

    Science.gov (United States)

    Ross, Claire; Dimitrova, Stoyanka; Howard, Louise M; Dewey, Michael; Zimmerman, Cathy; Oram, Siân

    2015-08-20

    (1) To estimate the proportion of National Health Service (NHS) professionals who have come into contact with trafficked people and (2) to measure NHS professionals' knowledge and confidence to respond to human trafficking. A cross-sectional survey. Face-to-face mandatory child protection and/or vulnerable adults training sessions at 10 secondary healthcare provider organisations in England, and meetings of the UK College of Emergency Medicine. 782/892 (84.4%) NHS professionals participated, including from emergency medicine, maternity, mental health, paediatrics and other clinical disciplines. Self-completed questionnaire developed by an expert panel. Questionnaire asks about prior training and contact with potential victims of trafficking, perceived and actual human trafficking knowledge, confidence in responding to human trafficking, and interest in future human trafficking training. 13% participants reported previous contact with a patient they knew or suspected of having been trafficked; among maternity services professionals this was 20.4%. However, 86.8% (n=679) reported lacking knowledge of what questions to ask to identify potential victims and 78.3% (n=613) reported that they had insufficient training to assist trafficked people. 71% (n=556), 67.5% (n=528) and 53.4% (n=418) lacked confidence in making appropriate referrals for men, women and children, respectively, who had been trafficked. 95.3% (n=746) of respondents were unaware of the scale of human trafficking in the UK, and 76.5% (n=598) were unaware that calling the police could put patients in more danger. Psychometric analysis showed that subscales measuring perceived knowledge, actual knowledge and confidence to respond to human trafficking demonstrated good internal consistency (Cronbach's αs 0.93, 0.63 and 0.64, respectively) and internal correlations. NHS professionals working in secondary care are in contact with potential victims of human trafficking, but lack knowledge and confidence in

  14. Distinct migration and contact dynamics of resting and IL-2-activated human natural killer cells

    Directory of Open Access Journals (Sweden)

    Per Erik Olofsson

    2014-03-01

    Full Text Available Natural killer (NK cells serve as one of the first lines of defense against viral infections and transformed cells. NK cell cytotoxicity is not dependent on antigen presentation by target cells, but is dependent on integration of activating and inhibitory signals triggered by receptor–ligand interactions formed at a tight intercellular contact between the NK and target cell, i.e. the immune synapse. We have studied the single-cell migration behavior and target-cell contact dynamics of resting and IL-2-activated human peripheral blood NK cells. Small populations of NK cells and target cells were confined in microwells and imaged by fluorescence microscopy for >8 h. Only the IL-2-activated population of NK cells showed efficient cytotoxicity against the human embryonic kidney (HEK 293T target cells. We found that although the average migration speeds were comparable, activated NK cells showed significantly more dynamic migration behavior, with more frequent transitions between periods of low and high motility. Resting NK cells formed fewer and weaker contacts with target cells, which manifested as shorter conjugation times and in many cases a complete lack of post-conjugation attachment to target cells. Activated NK cells were approximately twice as big as the resting cells, displayed a more migratory phenotype, and were more likely to employ motile scanning of the target cell surface during conjugation. Taken together, our experiments quantify, at the single-cell level, how activation by IL-2 leads to altered NK cell cytotoxicity, migration behavior and contact dynamics.

  15. Contact and perspective taking improve humanness standards and perceptions of humanness of older adults and people with dementia: a cross-sectional survey study.

    Science.gov (United States)

    Miron, Anca M; McFadden, Susan H; Hermus, Nathan J; Buelow, Jennifer; Nazario, Amanda S; Seelman, Katarena

    2017-10-01

    No empirical work has systematically explored perceptions of humanness of people with dementia and of older adults and the variables that could improve these perceptions. We thus investigated the role of contact and perspective taking in improving perceptions of humanness of these social groups. To do so, we developed a new concept, humanness standards, defined as the amount of evidence of ability impairment needed to conclude that elderly people and those with dementia have lost personhood. We used a cross-sectional survey design (n = 619) to assess participants' humanness standards and perceptions of uniquely human characteristics and human nature characteristics of two social groups (people with dementia and older adults). Half the participants (n = 311) completed a survey about people with dementia and half (n = 308) assessed older adults. People with dementia were perceived as possessing humanness characteristics to a lesser extent than were older adults. For both groups, contact predicted enhanced perceptions of humanness characteristics. Participants' degree of contact with individuals with dementia also predicted humanness standards, but only under low perspective-taking conditions. As predicted, for older adults, participants set the highest humanness impairment thresholds in the high contact/high perspective-taking condition. We conclude that while social programs that bring persons with dementia and other individuals in contact could change humanness standards and perceptions of humanness characteristics of people with dementia, in the case of elderly adults, the contact must be supplemented by variables that facilitate taking the perspective of the person.

  16. Fast ray-tracing of human eye optics on Graphics Processing Units.

    Science.gov (United States)

    Wei, Qi; Patkar, Saket; Pai, Dinesh K

    2014-05-01

    We present a new technique for simulating retinal image formation by tracing a large number of rays from objects in three dimensions as they pass through the optic apparatus of the eye to objects. Simulating human optics is useful for understanding basic questions of vision science and for studying vision defects and their corrections. Because of the complexity of computing such simulations accurately, most previous efforts used simplified analytical models of the normal eye. This makes them less effective in modeling vision disorders associated with abnormal shapes of the ocular structures which are hard to be precisely represented by analytical surfaces. We have developed a computer simulator that can simulate ocular structures of arbitrary shapes, for instance represented by polygon meshes. Topographic and geometric measurements of the cornea, lens, and retina from keratometer or medical imaging data can be integrated for individualized examination. We utilize parallel processing using modern Graphics Processing Units (GPUs) to efficiently compute retinal images by tracing millions of rays. A stable retinal image can be generated within minutes. We simulated depth-of-field, accommodation, chromatic aberrations, as well as astigmatism and correction. We also show application of the technique in patient specific vision correction by incorporating geometric models of the orbit reconstructed from clinical medical images. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  17. Ion therapy for uveal melanoma in new human eye phantom based on GEANT4 toolkit

    Energy Technology Data Exchange (ETDEWEB)

    Mahdipour, Seyed Ali [Physics Department, Hakim Sabzevari University, Sabzevar (Iran, Islamic Republic of); Mowlavi, Ali Asghar, E-mail: amowlavi@hsu.ac.ir [Physics Department, Hakim Sabzevari University, Sabzevar (Iran, Islamic Republic of); ICTP, Associate Federation Scheme, Medical Physics Field, Trieste (Italy)

    2016-07-01

    Radiotherapy with ion beams like proton and carbon has been used for treatment of eye uveal melanoma for many years. In this research, we have developed a new phantom of human eye for Monte Carlo simulation of tumors treatment to use in GEANT4 toolkit. Total depth−dose profiles for the proton, alpha, and carbon incident beams with the same ranges have been calculated in the phantom. Moreover, the deposited energy of the secondary particles for each of the primary beams is calculated. The dose curves are compared for 47.8 MeV proton, 190.1 MeV alpha, and 1060 MeV carbon ions that have the same range in the target region reaching to the center of tumor. The passively scattered spread-out Bragg peak (SOBP) for each incident beam as well as the flux curves of the secondary particles including neutron, gamma, and positron has been calculated and compared for the primary beams. The high sharpness of carbon beam's Bragg peak with low lateral broadening is the benefit of this beam in hadrontherapy but it has disadvantages of dose leakage in the tail after its Bragg peak and high intensity of neutron production. However, proton beam, which has a good conformation with tumor shape owing to the beam broadening caused by scattering, can be a good choice for the large-size tumors.

  18. Ion therapy for uveal melanoma in new human eye phantom based on GEANT4 toolkit

    International Nuclear Information System (INIS)

    Mahdipour, Seyed Ali; Mowlavi, Ali Asghar

    2016-01-01

    Radiotherapy with ion beams like proton and carbon has been used for treatment of eye uveal melanoma for many years. In this research, we have developed a new phantom of human eye for Monte Carlo simulation of tumors treatment to use in GEANT4 toolkit. Total depth−dose profiles for the proton, alpha, and carbon incident beams with the same ranges have been calculated in the phantom. Moreover, the deposited energy of the secondary particles for each of the primary beams is calculated. The dose curves are compared for 47.8 MeV proton, 190.1 MeV alpha, and 1060 MeV carbon ions that have the same range in the target region reaching to the center of tumor. The passively scattered spread-out Bragg peak (SOBP) for each incident beam as well as the flux curves of the secondary particles including neutron, gamma, and positron has been calculated and compared for the primary beams. The high sharpness of carbon beam's Bragg peak with low lateral broadening is the benefit of this beam in hadrontherapy but it has disadvantages of dose leakage in the tail after its Bragg peak and high intensity of neutron production. However, proton beam, which has a good conformation with tumor shape owing to the beam broadening caused by scattering, can be a good choice for the large-size tumors.

  19. Use of Eye Tracking as an Innovative Instructional Method in Surgical Human Anatomy.

    Science.gov (United States)

    Sánchez-Ferrer, María Luísa; Grima-Murcia, María Dolores; Sánchez-Ferrer, Francisco; Hernández-Peñalver, Ana Isabel; Fernández-Jover, Eduardo; Sánchez Del Campo, Francisco

    Tobii glasses can record corneal infrared light reflection to track pupil position and to map gaze focusing in the video recording. Eye tracking has been proposed for use in training and coaching as a visually guided control interface. The aim of our study was to test the potential use of these glasses in various situations: explanations of anatomical structures on tablet-type electronic devices, explanations of anatomical models and dissected cadavers, and during the prosection thereof. An additional aim of the study was to test the use of the glasses during laparoscopies performed on Thiel-embalmed cadavers (that allows pneumoinsufflation and exact reproduction of the laparoscopic surgical technique). The device was also tried out in actual surgery (both laparoscopy and open surgery). We performed a pilot study using the Tobii glasses. Dissection room at our School of Medicine and in the operating room at our Hospital. To evaluate usefulness, a survey was designed for use among students, instructors, and practicing physicians. The results were satisfactory, with the usefulness of this tool supported by more than 80% positive responses to most questions. There was no inconvenience for surgeons and that patient safety was ensured in the real laparoscopy. To our knowledge, this is the first publication to demonstrate the usefulness of eye tracking in practical instruction of human anatomy, as well as in teaching clinical anatomy and surgical techniques in the dissection and operating rooms. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  20. Frequency-Dependent Modulation of Regional Synchrony in the Human Brain by Eyes Open and Eyes Closed Resting-States.

    Science.gov (United States)

    Song, Xiaopeng; Zhou, Shuqin; Zhang, Yi; Liu, Yijun; Zhu, Huaiqiu; Gao, Jia-Hong

    2015-01-01

    The eyes-open (EO) and eyes-closed (EC) states have differential effects on BOLD-fMRI signal dynamics, affecting both the BOLD oscillation frequency of a single voxel and the regional homogeneity (ReHo) of several neighboring voxels. To explore how the two resting-states modulate the local synchrony through different frequency bands, we decomposed the time series of each voxel into several components that fell into distinct frequency bands. The ReHo in each of the bands was calculated and compared between the EO and EC conditions. The cross-voxel correlations between the mean frequency and the overall ReHo of each voxel's original BOLD series in different brain areas were also calculated and compared between the two states. Compared with the EC state, ReHo decreased with EO in a wide frequency band of 0.01-0.25 Hz in the bilateral thalamus, sensorimotor network, and superior temporal gyrus, while ReHo increased significantly in the band of 0-0.01 Hz in the primary visual cortex, and in a higher frequency band of 0.02-0.1 Hz in the higher order visual areas. The cross-voxel correlations between the frequency and overall ReHo were negative in all the brain areas but varied from region to region. These correlations were stronger with EO in the visual network and the default mode network. Our results suggested that different frequency bands of ReHo showed different sensitivity to the modulation of EO-EC states. The better spatial consistency between the frequency and overall ReHo maps indicated that the brain might adopt a stricter frequency-dependent configuration with EO than with EC.

  1. Role of human papilloma virus infection and oral-genital contact in oral cancer ethiopathogenesis.

    Science.gov (United States)

    Stanko, P; Kruzliak, P; Labas, P

    2013-01-01

    Head and neck squamous cell carcinoma and especially oropharyngeal squamous cell carcinoma is a very significant cause of morbidity and mortality. The majors risk factors of these tumors are tobacco smoking, chewing and alcohol consumption. But there is a group, non-drinking and non-smoking, patients with oropharyngeal squamous cell carcinoma. In these patients may be oral-genital contact and human papillomavirus infection the major risk factor for oral carcinogenesis. Aim of this review is to point out this fact in correlation with clinical studies and clinical conclusion for medical practice (Fig. 1, Ref. 32).

  2. An exploratory study on the driving method of speech synthesis based on the human eye reading imaging data

    Science.gov (United States)

    Gao, Pei-pei; Liu, Feng

    2016-10-01

    With the development of information technology and artificial intelligence, speech synthesis plays a significant role in the fields of Human-Computer Interaction Techniques. However, the main problem of current speech synthesis techniques is lacking of naturalness and expressiveness so that it is not yet close to the standard of natural language. Another problem is that the human-computer interaction based on the speech synthesis is too monotonous to realize mechanism of user subjective drive. This thesis introduces the historical development of speech synthesis and summarizes the general process of this technique. It is pointed out that prosody generation module is an important part in the process of speech synthesis. On the basis of further research, using eye activity rules when reading to control and drive prosody generation was introduced as a new human-computer interaction method to enrich the synthetic form. In this article, the present situation of speech synthesis technology is reviewed in detail. Based on the premise of eye gaze data extraction, using eye movement signal in real-time driving, a speech synthesis method which can express the real speech rhythm of the speaker is proposed. That is, when reader is watching corpora with its eyes in silent reading, capture the reading information such as the eye gaze duration per prosodic unit, and establish a hierarchical prosodic pattern of duration model to determine the duration parameters of synthesized speech. At last, after the analysis, the feasibility of the above method is verified.

  3. A new 3D reconstituted human corneal epithelium model as an alternative method for the eye irritation test.

    Science.gov (United States)

    Jung, Kyoung-Mi; Lee, Su-Hyon; Ryu, Yang-Hwan; Jang, Won-Hee; Jung, Haeng-Sun; Han, Ju-Hee; Seok, Seung-Hyeok; Park, Jae-Hak; Son, Youngsook; Park, Young-Ho; Lim, Kyung-Min

    2011-02-01

    Many efforts are being made to develop new alternative in vitro test methods for the eye irritation test. Here we report a new reconstructed human corneal epithelial model (MCTT HCE model) prepared from primary-cultured human limbal epithelial cells as a new alternative in vitro eye irritation test method. In histological and immunohistochemical observation, MCTT HCE model displayed a morphology and biomarker expressions similar to intact human cornea. Moreover, the barrier function was well preserved as measured by high transepithelial electrical resistance, effective time-50 for Triton X-100, and corneal thickness. To employ the model as a new alternative method for eye irritation test, protocol refinement was performed and optimum assay condition was determined including treatment time, treatment volume, post-incubation time and rinsing method. Using the refined protocol, 25 reference chemicals with known eye irritation potentials were tested. With the viability cut-off value at 50%, chemicals were classified to irritant or non-irritant. When compared with GHS classification, the MCTT HCE model showed the accuracy of 88%, sensitivity of 100% and specificity of 77%. These results suggest that the MCTT HCE model might be useful as a new alternative eye irritation test method. Copyright © 2010 Elsevier Ltd. All rights reserved.

  4. DESIGN AND APPLICATION OF SENSOR FOR RECORDING SOUNDS OVER HUMAN EYE AND NOSE

    NARCIS (Netherlands)

    JOURNEE, HL; VANBRUGGEN, AC; VANDERMEER, JJ; DEJONGE, AB; MOOIJ, JJA

    The recording of sounds over the oribt of the eye has been found to be useful in the detection of intracranial aneurysms. A hydrophone for auscultation over the eye has been developed and is tested under controlled conditions. The tests consist of measurement over the eyes in three healthy

  5. Reconstituted human corneal epithelium: a new alternative to the Draize eye test for the assessment of the eye irritation potential of chemicals and cosmetic products.

    Science.gov (United States)

    Doucet, O; Lanvin, M; Thillou, C; Linossier, C; Pupat, C; Merlin, B; Zastrow, L

    2006-06-01

    The aim of this study was to evaluate the interest of a new three-dimensional epithelial model cultivated from human corneal cells to replace animal testing in the assessment of eye tolerance. To this end, 65 formulated cosmetic products and 36 chemicals were tested by means of this in vitro model using a simplified toxicokinetic approach. The chemicals were selected from the ECETOC data bank and the EC/HO International validation study list. Very satisfactory results were obtained in terms of concordance with the Draize test data for the formulated cosmetic products. Moreover, the response of the corneal model appeared predictive of human ocular response clinically observed by ophthalmologists. The in vitro scores for the chemicals tested strongly correlated with their respective scores in vivo. For all the compounds tested, the response of the corneal model to irritants was similar regardless of their chemical structure, suggesting a good robustness of the prediction model proposed. We concluded that this new three-dimensional epithelial model, developed from human corneal cells, could be promising for the prediction of eye irritation induced by chemicals and complex formulated products, and that these two types of materials should be tested using a similar protocol. A simple shortening of the exposure period was required for the chemicals assumed to be more aggressively irritant to the epithelial tissues than the cosmetic formulae.

  6. CON4EI: SkinEthic™ Human Corneal Epithelium Eye Irritation Test (SkinEthic™ HCE EIT) for hazard identification and labelling of eye irritating chemicals.

    Science.gov (United States)

    Van Rompay, A R; Alépée, N; Nardelli, L; Hollanders, K; Leblanc, V; Drzewiecka, A; Gruszka, K; Guest, R; Kandarova, H; Willoughby, J A; Verstraelen, S; Adriaens, E

    2018-06-01

    Assessment of ocular irritancy is an international regulatory requirement and a necessary step in the safety evaluation of industrial and consumer products. Although a number of in vitro ocular irritation assays exist, none are capable of fully categorizing chemicals as a stand-alone assay. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was developed with the goal of assessing the reliability of eight in vitro/alternative test methods as well as establishing an optimal tiered-testing strategy. One of the in vitro assays selected was the validated SkinEthic™ Human Corneal Epithelium Eye Irritation Test method (SkinEthic™ HCE EIT). The SkinEthic™ HCE EIT has already demonstrated its capacity to correctly identify chemicals (both substances and mixtures) not requiring classification and labelling for eye irritation or serious eye damage (No Category). The goal of this study was to evaluate the performance of the SkinEthic™ HCE EIT test method in terms of the important in vivo drivers of classification. For the performance with respect to the drivers all in vivo Cat 1 and No Cat chemicals were 100% correctly identified. For Cat 2 chemicals the liquids and the solids had a sensitivity of 100% and 85.7%, respectively. For the SkinEthic™ HCE EIT test method, 100% concordance in predictions (No Cat versus No prediction can be made) between the two participating laboratories was obtained. The accuracy of the SkinEthic™ HCE EIT was 97.5% with 100% sensitivity and 96.9% specificity. The SkinEthic™ HCE EIT confirms its excellent results of the validation studies. Copyright © 2017. Published by Elsevier Ltd.

  7. Radiocarbon Dating of the Human Eye Lens Crystallines Reveal Proteins without Carbon Turnover throughout Life

    Science.gov (United States)

    Lynnerup, Niels; Kjeldsen, Henrik; Heegaard, Steffen; Jacobsen, Christina; Heinemeier, Jan

    2008-01-01

    Background Lens crystallines are special proteins in the eye lens. Because the epithelial basement membrane (lens capsule) completely encloses the lens, desquamation of aging cells is impossible, and due to the complete absence of blood vessels or transport of metabolites in this area, there is no subsequent remodelling of these fibers, nor removal of degraded lens fibers. Human tissue ultimately derives its 14C content from the atmospheric carbon dioxide. The 14C content of the lens proteins thus reflects the atmospheric content of 14C when the lens crystallines were formed. Precise radiocarbon dating is made possible by comparing the 14C content of the lens crystallines to the so-called bomb pulse, i.e. a plot of the atmospheric 14C content since the Second World War, when there was a significant increase due to nuclear-bomb testing. Since the change in concentration is significant even on a yearly basis this allows very accurate dating. Methodology/Principal Findings Our results allow us to conclude that the crystalline formation in the lens nucleus almost entirely takes place around the time of birth, with a very small, and decreasing, continuous formation throughout life. The close relationship may be further expressed as a mathematical model, which takes into account the timing of the crystalline formation. Conclusions/Significance Such a life-long permanence of human tissue has hitherto only been described for dental enamel. In confront to dental enamel it must be held in mind that the eye lens is a soft structure, subjected to almost continuous deformation, due to lens accommodation, yet its most important constituent, the lens crystalline, is never subject to turnover or remodelling once formed. The determination of the 14C content of various tissues may be used to assess turnover rates and degree of substitution (for example for brain cell DNA). Potential targets may be nervous tissues in terms of senile or pre-senile degradation, as well as other highly

  8. Radiocarbon dating of the human eye lens crystallines reveal proteins without carbon turnover throughout life.

    Directory of Open Access Journals (Sweden)

    Niels Lynnerup

    Full Text Available BACKGROUND: Lens crystallines are special proteins in the eye lens. Because the epithelial basement membrane (lens capsule completely encloses the lens, desquamation of aging cells is impossible, and due to the complete absence of blood vessels or transport of metabolites in this area, there is no subsequent remodelling of these fibers, nor removal of degraded lens fibers. Human tissue ultimately derives its (14C content from the atmospheric carbon dioxide. The (14C content of the lens proteins thus reflects the atmospheric content of (14C when the lens crystallines were formed. Precise radiocarbon dating is made possible by comparing the (14C content of the lens crystallines to the so-called bomb pulse, i.e. a plot of the atmospheric (14C content since the Second World War, when there was a significant increase due to nuclear-bomb testing. Since the change in concentration is significant even on a yearly basis this allows very accurate dating. METHODOLOGY/PRINCIPAL FINDINGS: Our results allow us to conclude that the crystalline formation in the lens nucleus almost entirely takes place around the time of birth, with a very small, and decreasing, continuous formation throughout life. The close relationship may be further expressed as a mathematical model, which takes into account the timing of the crystalline formation. CONCLUSIONS/SIGNIFICANCE: Such a life-long permanence of human tissue has hitherto only been described for dental enamel. In confront to dental enamel it must be held in mind that the eye lens is a soft structure, subjected to almost continuous deformation, due to lens accommodation, yet its most important constituent, the lens crystalline, is never subject to turnover or remodelling once formed. The determination of the (14C content of various tissues may be used to assess turnover rates and degree of substitution (for example for brain cell DNA. Potential targets may be nervous tissues in terms of senile or pre

  9. Computing the influences of different Intraocular Pressures on the human eye components using computational fluid-structure interaction model.

    Science.gov (United States)

    Karimi, Alireza; Razaghi, Reza; Navidbakhsh, Mahdi; Sera, Toshihiro; Kudo, Susumu

    2017-01-01

    Intraocular Pressure (IOP) is defined as the pressure of aqueous in the eye. It has been reported that the normal range of IOP should be within the 10-20 mmHg with an average of 15.50 mmHg among the ophthalmologists. Keratoconus is an anti-inflammatory eye disorder that debilitated cornea unable to reserve the normal structure contrary to the IOP in the eye. Consequently, the cornea would bulge outward and invoke a conical shape following by distorted vision. In addition, it is known that any alterations in the structure and composition of the lens and cornea would exceed a change of the eye ball as well as the mechanical and optical properties of the eye. Understanding the precise alteration of the eye components' stresses and deformations due to different IOPs could help elucidate etiology and pathogenesis to develop treatments not only for keratoconus but also for other diseases of the eye. In this study, at three different IOPs, including 10, 20, and 30 mmHg the stresses and deformations of the human eye components were quantified using a Three-Dimensional (3D) computational Fluid-Structure Interaction (FSI) model of the human eye. The results revealed the highest amount of von Mises stress in the bulged region of the cornea with 245 kPa at the IOP of 30 mmHg. The lens was also showed the von Mises stress of 19.38 kPa at the IOPs of 30 mmHg. In addition, by increasing the IOP from 10 to 30 mmHg, the radius of curvature in the cornea and lens was increased accordingly. In contrast, the sclera indicated its highest stress at the IOP of 10 mmHg due to over pressure phenomenon. The variation of IOP illustrated a little influence in the amount of stress as well as the resultant displacement of the optic nerve. These results can be used for understanding the amount of stresses and deformations in the human eye components due to different IOPs as well as for clarifying significant role of IOP on the radius of curvature of the cornea and the lens.

  10. Desenvolvimento do olhar e do contato ocular em lactentes de zero a quatro meses de idade The development of looking behavior and eye-contact in breast feeding children aged between 0 and 4 months

    Directory of Open Access Journals (Sweden)

    Aline Elise Gerbelli Belini

    2010-03-01

    Full Text Available OBJETIVOS: investigar o desenvolvimento do contato ocular e do comportamento visual de bebês entre zero e quatro meses. MÉTODOS: dezessete bebês típicos foram filmados mensalmente por 30 minutos, sendo transcritas 11 categorias de observação do olhar, quantificadas e tratadas estatisticamente através dos testes de Friedman (α = 0,050 e dos Postos Sinalizados de Wilcoxon (α de Bonferroni = 0,010. RESULTADOS: houve diferenças estatisticamente significantes nas frequências das categorias: "olhar para os olhos da mãe" (pOBJECTIVES: to investigate the development of eye-contact and visual behavior in babies aged between 0 and 4 months. METHODS: sixteen normal babies were filmed monthly for 30 minutes, and 11 eleven visual behavior categories observed and transcribed. These were then quantified and treated statistically using the Friedman test (α = 0.050 and Wilcoxon's Signed Rank test (Bonferroni's α = 0,010. RESULTS: there were statistical differences in frequency between the various categories: "looking mother in the eye" (p<0.001, "looking mother in the face" (p<0.001, "looking at an object" (p<0.001, "looking at the researcher" (p<0.001, "actively looking at the surroundings" (p<0.001, "passively looking at the surroundings" (p<0.001, "looking at own body" (p=0.001 and "eyes closed" (p=0.005. Eye-contact was detected in the third week of life in 64.7% and developed during the first five months of life (p=0.010 in 50% of the intervals between data collection. CONCLUSIONS: eye-contact can be detected from the neonatal period onwards and develops over the first few months of life. The frequency of the baby's eye-contact with its mother increases longitudinally in the first four months. Other focuses of attention, apart from the mother's eyes, are also fundamental during the early stages of development outside the womb.

  11. PHYSICAL CONTACT BETWEEN HUMAN VASCULAR ENDOTHELIAL AND SMOOTH MUSCLE CELLS MODULATES CYTOSOLIC AND NUCLEAR CALCIUM HOMEOSTASIS.

    Science.gov (United States)

    Hassan, Ghada S; Jacques, Danielle; D'Orleans-Juste, Pedro; Magder, Sheldon; Bkaily, Ghassan

    2018-05-14

    The interaction between vascular endothelial cells (VECs) and vascular smooth muscle cells (VSMCs) plays an important role in the modulation of vascular tone. There is however no information on whether direct physical communication regulates the intracellular calcium levels of human VECs (hVECs) and/or hVSMCs . Thus, the objective of the study is to verify whether co-culture of hVECs and hVSMCs modulates cytosolic ([Ca2+]c) and nuclear calcium ([Ca2+]n) levels via physical contact and/or factors released by both cell types. Quantitative 3D confocal microscopy for [Ca2+]c and [Ca2+]n measurement was performed in cultured hVECs or hVSMCs or in co-culture of hVECs-hVSMCs. Our results show that: 1) physical contact between hVECs-hVECs or hVSMCs-hVSMCs does not affect [Ca2+]c and [Ca2+]n in these two cell types; 2) physical contact between hVECs and hVSMCs induces a significant increase only of [Ca2+]n of hVECs without affecting the level of [Ca2+]c and [Ca2+]n of hVSMCs; and 3) preconditioned culture medium of hVECs or hVSMCs does not affect [Ca2+]c and [Ca2+]n of both types of cells. We concluded that physical contact between hVECs and hVSMCs only modulates [Ca2+]n in hVECs. The increase of [Ca2+]n in hVECs may modulate nuclear functions that are calcium dependent.

  12. Towards free 3D end-point control for robotic-assisted human reaching using binocular eye tracking.

    Science.gov (United States)

    Maimon-Dror, Roni O; Fernandez-Quesada, Jorge; Zito, Giuseppe A; Konnaris, Charalambos; Dziemian, Sabine; Faisal, A Aldo

    2017-07-01

    Eye-movements are the only directly observable behavioural signals that are highly correlated with actions at the task level, and proactive of body movements and thus reflect action intentions. Moreover, eye movements are preserved in many movement disorders leading to paralysis (or amputees) from stroke, spinal cord injury, Parkinson's disease, multiple sclerosis, and muscular dystrophy among others. Despite this benefit, eye tracking is not widely used as control interface for robotic interfaces in movement impaired patients due to poor human-robot interfaces. We demonstrate here how combining 3D gaze tracking using our GT3D binocular eye tracker with custom designed 3D head tracking system and calibration method enables continuous 3D end-point control of a robotic arm support system. The users can move their own hand to any location of the workspace by simple looking at the target and winking once. This purely eye tracking based system enables the end-user to retain free head movement and yet achieves high spatial end point accuracy in the order of 6 cm RMSE error in each dimension and standard deviation of 4 cm. 3D calibration is achieved by moving the robot along a 3 dimensional space filling Peano curve while the user is tracking it with their eyes. This results in a fully automated calibration procedure that yields several thousand calibration points versus standard approaches using a dozen points, resulting in beyond state-of-the-art 3D accuracy and precision.

  13. Computational and experimental research on infrared trace by human being contact

    Energy Technology Data Exchange (ETDEWEB)

    Xiong Zonglong; Yang Kuntao; Ding Wenxiu; Zhang Nanyangsheng; Zheng Wenheng

    2010-06-20

    The indoor detection of the human body's thermal trace plays an important role in the fields of infrared detecting, scouting, infrared camouflage, and infrared rescuing and tracking. Currently, quantitative description and analysis for this technology are lacking due to the absence of human infrared radiation analysis. To solve this problem, we study the heating and cooling process by observing body contact and removal on an object, respectively. Through finite-element simulation and carefully designed experiments, an analytical model of the infrared trace of body contact is developed based on infrared physics and heat transfer theory. Using this model, the impact of body temperature on material thermal parameters is investigated. The sensitivity of material thermal parameters, the thermal distribution, and the changes of the thermograph's contrast are then found and analyzed. Excellent matching results achieved between the simulation and the experiments demonstrate the strong impact of temperature on material thermal parameters. Conclusively, the new model, simulation, and experimental results are beneficial to the future development and implementation of infrared trace technology.

  14. Computational and experimental research on infrared trace by human being contact

    International Nuclear Information System (INIS)

    Xiong Zonglong; Yang Kuntao; Ding Wenxiu; Zhang Nanyangsheng; Zheng Wenheng

    2010-01-01

    The indoor detection of the human body's thermal trace plays an important role in the fields of infrared detecting, scouting, infrared camouflage, and infrared rescuing and tracking. Currently, quantitative description and analysis for this technology are lacking due to the absence of human infrared radiation analysis. To solve this problem, we study the heating and cooling process by observing body contact and removal on an object, respectively. Through finite-element simulation and carefully designed experiments, an analytical model of the infrared trace of body contact is developed based on infrared physics and heat transfer theory. Using this model, the impact of body temperature on material thermal parameters is investigated. The sensitivity of material thermal parameters, the thermal distribution, and the changes of the thermograph's contrast are then found and analyzed. Excellent matching results achieved between the simulation and the experiments demonstrate the strong impact of temperature on material thermal parameters. Conclusively, the new model, simulation, and experimental results are beneficial to the future development and implementation of infrared trace technology.

  15. Verification of the lack of correlation between age and longitudinal chromatic aberrations of the human eye from the visible to the infrared

    Science.gov (United States)

    Nakajima, Masashi; Hiraoka, Takahiro; Hirohara, Yoko; Oshika, Tetsuro; Mihashi, Toshifumi

    2015-01-01

    Several researchers studied the longitudinal chromatic aberration (LCA) of the human eye and observed that it does not change due to age. We measured the LCA of 45 subjects’ normal right eyes at three distinct wavelengths (561, 690, and 840 nm) using a Hartmann–Shack wavefront aberrometer (HSWA) while consecutively switching between three light sources for wavefront sensing. We confirmed that the LCA of the human eye does not change due to age between 22 and 57 years. PMID:26203391

  16. Assessing the role of contact tracing in a suspected H7N2 influenza A outbreak in humans in Wales

    Directory of Open Access Journals (Sweden)

    Salmon Roland

    2010-05-01

    Full Text Available Abstract Background The detailed analysis of an outbreak database has been undertaken to examine the role of contact tracing in controlling an outbreak of possible avian influenza in humans. The outbreak, initiating from the purchase of infected domestic poultry, occurred in North Wales during May and June 2007. During this outbreak, extensive contact tracing was carried out. Following contact tracing, cases and contacts believed to be at risk of infection were given treatment/prophylaxis. Methods We analyse the database of cases and their contacts identified for the purposes of contact tracing in relation to both the contact tracing burden and effectiveness. We investigate the distribution of numbers of contacts identified, and use network structure to explore the speed with which treatment/prophylaxis was made available and to estimate the risk of transmission in different settings. Results Fourteen cases of suspected H7N2 influenza A in humans were associated with a confirmed outbreak among poultry in May-June 2007. The contact tracing dataset consisted of 254 individuals (cases and contacts, of both poultry and humans who were linked through a network of social contacts. Of these, 102 individuals were given treatment or prophylaxis. Considerable differences between individuals' contact patterns were observed. Home and workplace encounters were more likely to result in transmission than encounters in other settings. After an initial delay, while the outbreak proceeded undetected, contact tracing rapidly caught up with the cases and was effective in reducing the time between onset of symptoms and treatment/prophylaxis. Conclusions Contact tracing was used to link together the individuals involved in this outbreak in a social network, allowing the identification of the most likely paths of transmission and the risks of different types of interactions to be assessed. The outbreak highlights the substantial time and cost involved in contact

  17. Assessing the role of contact tracing in a suspected H7N2 influenza A outbreak in humans in Wales.

    Science.gov (United States)

    Eames, Ken T D; Webb, Cerian; Thomas, Kathrin; Smith, Josie; Salmon, Roland; Temple, J Mark F

    2010-05-28

    The detailed analysis of an outbreak database has been undertaken to examine the role of contact tracing in controlling an outbreak of possible avian influenza in humans. The outbreak, initiating from the purchase of infected domestic poultry, occurred in North Wales during May and June 2007. During this outbreak, extensive contact tracing was carried out. Following contact tracing, cases and contacts believed to be at risk of infection were given treatment/prophylaxis. We analyse the database of cases and their contacts identified for the purposes of contact tracing in relation to both the contact tracing burden and effectiveness. We investigate the distribution of numbers of contacts identified, and use network structure to explore the speed with which treatment/prophylaxis was made available and to estimate the risk of transmission in different settings. Fourteen cases of suspected H7N2 influenza A in humans were associated with a confirmed outbreak among poultry in May-June 2007. The contact tracing dataset consisted of 254 individuals (cases and contacts, of both poultry and humans) who were linked through a network of social contacts. Of these, 102 individuals were given treatment or prophylaxis. Considerable differences between individuals' contact patterns were observed. Home and workplace encounters were more likely to result in transmission than encounters in other settings. After an initial delay, while the outbreak proceeded undetected, contact tracing rapidly caught up with the cases and was effective in reducing the time between onset of symptoms and treatment/prophylaxis. Contact tracing was used to link together the individuals involved in this outbreak in a social network, allowing the identification of the most likely paths of transmission and the risks of different types of interactions to be assessed. The outbreak highlights the substantial time and cost involved in contact tracing, even for an outbreak affecting few individuals. However, when

  18. Dry Eye

    Science.gov (United States)

    ... Eye » Facts About Dry Eye Listen Facts About Dry Eye Fact Sheet Blurb The National Eye Institute (NEI) ... and their families search for general information about dry eye. An eye care professional who has examined the ...

  19. An Interactive Method for Teaching Anatomy of the Human Eye for Medical Students in Ophthalmology Clinical Rotations

    Science.gov (United States)

    Kivell, Tracy L.; Doyle, Sara K.; Madden, Richard H.; Mitchell, Terry L.; Sims, Ershela L.

    2009-01-01

    Much research has shown the benefits of additional anatomical learning and dissection beyond the first year of medical school human gross anatomy, all the way through postgraduate medical training. We have developed an interactive method for teaching eye and orbit anatomy to medical students in their ophthalmology rotation at Duke University…

  20. Simultaneous recordings of human microsaccades and drifts with a contemporary video eye tracker and the search coil technique.

    Directory of Open Access Journals (Sweden)

    Michael B McCamy

    Full Text Available Human eyes move continuously, even during visual fixation. These "fixational eye movements" (FEMs include microsaccades, intersaccadic drift and oculomotor tremor. Research in human FEMs has grown considerably in the last decade, facilitated by the manufacture of noninvasive, high-resolution/speed video-oculography eye trackers. Due to the small magnitude of FEMs, obtaining reliable data can be challenging, however, and depends critically on the sensitivity and precision of the eye tracking system. Yet, no study has conducted an in-depth comparison of human FEM recordings obtained with the search coil (considered the gold standard for measuring microsaccades and drift and with contemporary, state-of-the art video trackers. Here we measured human microsaccades and drift simultaneously with the search coil and a popular state-of-the-art video tracker. We found that 95% of microsaccades detected with the search coil were also detected with the video tracker, and 95% of microsaccades detected with video tracking were also detected with the search coil, indicating substantial agreement between the two systems. Peak/mean velocities and main sequence slopes of microsaccades detected with video tracking were significantly higher than those of the same microsaccades detected with the search coil, however. Ocular drift was significantly correlated between the two systems, but drift speeds were higher with video tracking than with the search coil. Overall, our combined results suggest that contemporary video tracking now approaches the search coil for measuring FEMs.

  1. The Correlation between Daily Lens Wear Duration and Dry Eye Syndrome.

    Science.gov (United States)

    Lubis, Rodiah Rahmawaty; Gultom, Monica Tumiar Hanna

    2018-05-20

    To analyze the correlation between the daily lens wear duration and dry eye syndrome. This study was an analytic cross sectional study using consecutive sampling conducted among the students in Economy and Bussiness Faculty and Faculty of Humanities in University of Sumatera Utara aged between 17 to 23 that wore contact lens continously for at least a year and 5 days a week. The symptoms were assessed using Contact Lens Dry Eye Questionnaire-8 (CLDEQ-8) and interview about their contact lens comfort; eye drops usage, contact lens washing habit, daily circumstances, places to buy contact lens and personal experince in wearing contact lens. The questionnaire was completed by 53 students. All of them were female and wore softlens wearers. The mean duration of daily wear was 8.19 ± 2.20 hours. The most common symptom experienced was dry eye and the least symptom experienced was removing lens. The most frequent symptom experienced was closing eyes and the least frequent symptom experienced was removing lenses. This study used Exact Test as analysis statistic method. The result was p > 0.05 which means there is no correlation between daily lens wear duration and dry eye syndrome. This study showed that dry eye syndrome was not correlated with daily lens wear duration, but affected by many factors such as contact lens, lens care solution, eye drops usage and environment.

  2. Optical imaging of the chorioretinal vasculature in the living human eye.

    Science.gov (United States)

    Kim, Dae Yu; Fingler, Jeff; Zawadzki, Robert J; Park, Susanna S; Morse, Lawrence S; Schwartz, Daniel M; Fraser, Scott E; Werner, John S

    2013-08-27

    Detailed visualization of microvascular changes in the human retina is clinically limited by the capabilities of angiography imaging, a 2D fundus photograph that requires an intravenous injection of fluorescent dye. Whereas current angiography methods enable visualization of some retinal capillary detail, they do not adequately reveal the choriocapillaris or other microvascular features beneath the retina. We have developed a noninvasive microvascular imaging technique called phase-variance optical coherence tomography (pvOCT), which identifies vasculature three dimensionally through analysis of data acquired with OCT systems. The pvOCT imaging method is not only capable of generating capillary perfusion maps for the retina, but it can also use the 3D capabilities to segment the data in depth to isolate vasculature in different layers of the retina and choroid. This paper demonstrates some of the capabilities of pvOCT imaging of the anterior layers of choroidal vasculature of a healthy normal eye as well as of eyes with geographic atrophy (GA) secondary to age-related macular degeneration. The pvOCT data presented permit digital segmentation to produce 2D depth-resolved images of the retinal vasculature, the choriocapillaris, and the vessels in Sattler's and Haller's layers. Comparisons are presented between en face projections of pvOCT data within the superficial choroid and clinical angiography images for regions of GA. Abnormalities and vascular dropout observed within the choriocapillaris for pvOCT are compared with regional GA progression. The capability of pvOCT imaging of the microvasculature of the choriocapillaris and the anterior choroidal vasculature has the potential to become a unique tool to evaluate therapies and understand the underlying mechanisms of age-related macular degeneration progression.

  3. A novel device for head gesture measurement system in combination with eye-controlled human machine interface

    Science.gov (United States)

    Lin, Chern-Sheng; Ho, Chien-Wa; Chang, Kai-Chieh; Hung, San-Shan; Shei, Hung-Jung; Yeh, Mau-Shiun

    2006-06-01

    This study describes the design and combination of an eye-controlled and a head-controlled human-machine interface system. This system is a highly effective human-machine interface, detecting head movement by changing positions and numbers of light sources on the head. When the users utilize the head-mounted display to browse a computer screen, the system will catch the images of the user's eyes with CCD cameras, which can also measure the angle and position of the light sources. In the eye-tracking system, the program in the computer will locate each center point of the pupils in the images, and record the information on moving traces and pupil diameters. In the head gesture measurement system, the user wears a double-source eyeglass frame, so the system catches images of the user's head by using a CCD camera in front of the user. The computer program will locate the center point of the head, transferring it to the screen coordinates, and then the user can control the cursor by head motions. We combine the eye-controlled and head-controlled human-machine interface system for the virtual reality applications.

  4. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... edging closer, thanks to a wave of new technologies aiming to fix failing eye parts with human-made versions. ... tips and information about eye health and preserving your vision. Privacy ...

  5. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... edging closer, thanks to a wave of new technologies aiming to fix failing eye parts with human- ... Answers Free Newsletter Get ophthalmologist-reviewed tips and information about eye health and preserving your vision. Privacy ...

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... edging closer, thanks to a wave of new technologies aiming to fix failing eye parts with human-made versions. ... ophthalmologist-reviewed tips and information about eye health and preserving your vision. Privacy ...

  7. Contact variables for exposure to avian influenza H5N1 virus at the human-animal interface.

    Science.gov (United States)

    Rabinowitz, P; Perdue, M; Mumford, E

    2010-06-01

    Although the highly pathogenic avian influenza H5N1 virus continues to cause infections in both avian and human populations, the specific zoonotic risk factors remain poorly understood. This review summarizes available evidence regarding types of contact associated with transmission of H5N1 virus at the human-animal interface. A systematic search of the published literature revealed five analytical studies and 15 case reports describing avian influenza transmission from animals to humans for further review. Risk factors identified in analytical studies were compared, and World Health Organization-confirmed cases, identified in case reports, were classified according to type of contact reported using a standardized algorithm. Although cases were primarily associated with direct contact with sick/unexpectedly dead birds, some cases reported only indirect contact with birds or contaminated environments or contact with apparently healthy birds. Specific types of contacts or activities leading to exposure could not be determined from data available in the publications reviewed. These results support previous reports that direct contact with sick birds is not the only means of human exposure to avian influenza H5N1 virus. To target public health measures and disease awareness messaging for reducing the risk of zoonotic infection with avian influenza H5N1 virus, the specific types of contacts and activities leading to transmission need to be further understood. The role of environmental virus persistence, shedding of virus by asymptomatic poultry and disease pathophysiology in different avian species relative to human zoonotic risk, as well as specific modes of zoonotic transmission, should be determined.

  8. Lipid-protein interactions in plasma membranes of fiber cells isolated from the human eye lens.

    Science.gov (United States)

    Raguz, Marija; Mainali, Laxman; O'Brien, William J; Subczynski, Witold K

    2014-03-01

    The protein content in human lens membranes is extremely high, increases with age, and is higher in the nucleus as compared with the cortex, which should strongly affect the organization and properties of the lipid bilayer portion of intact membranes. To assess these effects, the intact cortical and nuclear fiber cell plasma membranes isolated from human lenses from 41- to 60-year-old donors were studied using electron paramagnetic resonance spin-labeling methods. Results were compared with those obtained for lens lipid membranes prepared from total lipid extracts from human eyes of the same age group [Mainali, L., Raguz, M., O'Brien, W. J., and Subczynski, W. K. (2013) Biochim. Biophys. Acta]. Differences were considered to be mainly due to the effect of membrane proteins. The lipid-bilayer portions of intact membranes were significantly less fluid than lipid bilayers of lens lipid membranes, prepared without proteins. The intact membranes were found to contain three distinct lipid environments termed the bulk lipid domain, boundary lipid domain, and trapped lipid domain. However, the cholesterol bilayer domain, which was detected in cortical and nuclear lens lipid membranes, was not detected in intact membranes. The relative amounts of bulk and trapped lipids were evaluated. The amount of lipids in domains uniquely formed due to the presence of membrane proteins was greater in nuclear membranes than in cortical membranes. Thus, it is evident that the rigidity of nuclear membranes is greater than that of cortical membranes. Also the permeability coefficients for oxygen measured in domains of nuclear membranes were significantly lower than appropriate coefficients measured in cortical membranes. Relationships between the organization of lipids into lipid domains in fiber cells plasma membranes and the organization of membrane proteins are discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. New patterns in human biogeography revealed by networks of contacts between linguistic groups.

    Science.gov (United States)

    Capitán, José A; Bock Axelsen, Jacob; Manrubia, Susanna

    2015-03-07

    Human languages differ broadly in abundance and are distributed highly unevenly on the Earth. In many qualitative and quantitative aspects, they strongly resemble biodiversity distributions. An intriguing and previously unexplored issue is the architecture of the neighbouring relationships between human linguistic groups. Here we construct and characterize these networks of contacts and show that they represent a new kind of spatial network with uncommon structural properties. Remarkably, language networks share a meaningful property with food webs: both are quasi-interval graphs. In food webs, intervality is linked to the existence of a niche space of low dimensionality; in language networks, we show that the unique relevant variable is the area occupied by the speakers of a language. By means of a range model analogous to niche models in ecology, we show that a geometric restriction of perimeter covering by neighbouring linguistic domains explains the structural patterns observed. Our findings may be of interest in the development of models for language dynamics or regarding the propagation of cultural innovations. In relation to species distribution, they pose the question of whether the spatial features of species ranges share architecture, and eventually generating mechanism, with the distribution of human linguistic groups. © 2015 The Author(s) Published by the Royal Society. All rights reserved.

  10. Estimation of the in vitro eye irritating and inflammatory potential of lipopolysaccharide (LPS) and dust by using reconstituted human corneal epithelium tissue cultures

    DEFF Research Database (Denmark)

    Cao, Yi; Arenholt-Bindslev, Dorthe; Kjærgaard, Søren K

    2015-01-01

    CONTEXT: Eye irritation is a common complaint in indoor environment, but the causes have still not been identified among the multiple exposures in house environments. To identify the potential environmental factors responsible for eye irritation and study the possible mechanisms, an in vitro model...... AND CONCLUSION: LPS and dust showed in vitro eye irritating and inflammatory potential, and cytokines/chemokines like IL-1β and IL-8 may be involved in the mechanisms of eye irritation. The HCE tissue culture may be used as an in vitro model to study environmental exposure induced eye irritation and inflammation....... for eye irritation is suggested. MATERIALS AND METHODS: In this study, reconstituted human corneal epithelium (HCE) tissue cultures were used to study the eye irritating and inflammatory potential of lipopolysaccharide (LPS) and dust. HCE tissue cultures were exposed to a range of concentrations of LPS...

  11. Diversity and antimicrobial susceptibility profiling of staphylococci isolated from bovine mastitis cases and close human contacts.

    Science.gov (United States)

    Schmidt, T; Kock, M M; Ehlers, M M

    2015-09-01

    The objectives of this study were to examine the diversity of Staphylococcus spp. recovered from bovine intramammary infections and humans working in close contact with the animals and to evaluate the susceptibility of the staphylococcal isolates to different antimicrobials. A total of 3,387 milk samples and 79 human nasal swabs were collected from 13 sampling sites in the KwaZulu-Natal province of South Africa. In total, 146 Staph. aureus isolates and 102 coagulase-negative staphylococci (CNS) were recovered from clinical and subclinical milk samples. Staphylococcusaureus was isolated from 12 (15.2%) of the human nasal swabs and 95 representative CNS were recovered for further characterization. The CNS were identified using multiplex-PCR assays, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS), and tuf gene sequencing. Seven Staphylococcus spp. were identified among the CNS of bovine origin, with Staph.chromogenes (78.4%) predominating. The predominant CNS species recovered from the human nasal swabs was Staph.epidermidis (80%) followed by Staph.chromogenes (6.3%). The antimicrobial susceptibility of all staphylococcal isolates was evaluated using disk diffusion and was supplemented by screening for specific antimicrobial resistance genes. Ninety-eight (67.1%) Staph.aureus isolates of bovine origin were pansusceptible; 39 (26.7%) isolates were resistant to a single class, and 7 (4.8%) isolates were resistant to 2 classes of antimicrobials. Two Staph. aureus (1.4%) isolates were multidrug-resistant. Resistance to penicillin was common, with 28.8% of the bovine and 75% of the human Staph. aureus isolates exhibiting resistance. A similar observation was made with the CNS, where 37.3% of the bovine and 89.5% of the human isolates were resistant to penicillin. Multidrug-resistance was common among the human CNS, with 39% of the isolates exhibiting resistance to 3 or more classes of antimicrobials. The antimicrobial

  12. Xenopus pax6 mutants affect eye development and other organ systems, and have phenotypic similarities to human aniridia patients.

    Science.gov (United States)

    Nakayama, Takuya; Fisher, Marilyn; Nakajima, Keisuke; Odeleye, Akinleye O; Zimmerman, Keith B; Fish, Margaret B; Yaoita, Yoshio; Chojnowski, Jena L; Lauderdale, James D; Netland, Peter A; Grainger, Robert M

    2015-12-15

    Mutations in the Pax6 gene cause ocular defects in both vertebrate and invertebrate animal species, and the disease aniridia in humans. Despite extensive experimentation on this gene in multiple species, including humans, we still do not understand the earliest effects on development mediated by this gene. This prompted us to develop pax6 mutant lines in Xenopus tropicalis taking advantage of the utility of the Xenopus system for examining early development and in addition to establish a model for studying the human disease aniridia in an accessible lower vertebrate. We have generated mutants in pax6 by using Transcription Activator-Like Effector Nuclease (TALEN) constructs for gene editing in X. tropicalis. Embryos with putative null mutations show severe eye abnormalities and changes in brain development, as assessed by changes in morphology and gene expression. One gene that we found is downregulated very early in development in these pax6 mutants is myc, a gene involved in pluripotency and progenitor cell maintenance and likely a mediator of some key pax6 functions in the embryo. Changes in gene expression in the developing brain and pancreas reflect other important functions of pax6 during development. In mutations with partial loss of pax6 function eye development is initially relatively normal but froglets show an underdeveloped iris, similar to the classic phenotype (aniridia) seen in human patients with PAX6 mutations. Other eye abnormalities observed in these froglets, including cataracts and corneal defects, are also common in human aniridia. The frog model thus allows us to examine the earliest deficits in eye formation as a result of pax6 lesions, and provides a useful model for understanding the developmental basis for the aniridia phenotype seen in humans. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Influence of Misalignment on High-Order Aberration Correction for Normal Human Eyes

    Science.gov (United States)

    Zhao, Hao-Xin; Xu, Bing; Xue, Li-Xia; Dai, Yun; Liu, Qian; Rao, Xue-Jun

    2008-04-01

    Although a compensation device can correct aberrations of human eyes, the effect will be degraded by its misalignment, especially for high-order aberration correction. We calculate the positioning tolerance of correction device for high-order aberrations, and within what degree the correcting effect is better than low-order aberration (defocus and astigmatism) correction. With fixed certain misalignment within the positioning tolerance, we calculate the residual wavefront rms aberration of the first-6 to first-35 terms along with the 3rd-5th terms of aberrations corrected, and the combined first-13 terms of aberrations are also studied under the same quantity of misalignment. However, the correction effect of high-order aberrations does not meliorate along with the increase of the high-order terms under some misalignment, moreover, some simple combined terms correction can achieve similar result as complex combinations. These results suggest that it is unnecessary to correct too much the terms of high-order aberrations which are difficult to accomplish in practice, and gives confidence to correct high-order aberrations out of the laboratory.

  14. Ab interno trabeculectomy: ultrastructural evidence and early tissue response in a human eye.

    Science.gov (United States)

    Ferrari, Ettore; Ortolani, Fulvia; Petrelli, Lucia; Contin, Magali; Pognuz, Derri Roman; Marchini, Maurizio; Bandello, Francesco

    2007-10-01

    To report the results of ultrastructural analysis of the postoperative effects of ab interno trabeculectomy in a human eye. Department of Ophthalmology, Palmanova Hospital, Palmanova, Udine, Italy. A 60-year-old woman with cataract and glaucoma had enucleation for a choroidal melanoma 10 days after ab interno trabeculectomy combined with phacoemulsification. A second ab interno trabeculectomy was performed after enucleation to evaluate the outcomes of the previous trabeculectomy. Light and transmission electron microscopy analyses were performed on samples excised from areas (1) not subjected to a procedure (control samples), (2) that had ab interno trabeculectomy before enucleation, and (3) that had ab interno trabeculectomy immediately after enucleation. Control samples showed normal trabecular features. Semithin sections of all ab interno trabeculectomy samples showed full-thickness removal of trabeculum segments, with Schlemm's canal lumen opening into the anterior chamber and apparent preservation of the adjacent structures. On ultrathin sections of samples that had ab interno trabeculectomy before enucleation, the endothelium lining the outer wall of Schlemm's canal and other angle components showed intact ultrastructural features. In trabecular beams that were not removed, the extracellular matrix appeared to have maintained its fine texture and was free of activated fibroblasts or leucocyte infiltrates. Observations confirm that ab interno trabeculectomy causes direct communication between Schlemm's canal lumen and the anterior chamber in vivo and immediately after enucleation during the early postoperative period. The absence of an evident inflammatory reaction in the examined case should be considered with caution because of possible tumor-induced immune suppression.

  15. Method to investigate temporal dynamics of ganglion and other retinal cells in the living human eye

    Science.gov (United States)

    Kurokawa, Kazuhiro; Liu, Zhuolin; Crowell, James; Zhang, Furu; Miller, Donald T.

    2018-02-01

    The inner retina is critical for visual processing, but much remains unknown about its neural circuitry and vulnerability to disease. A major bottleneck has been our inability to observe the structure and function of the cells composing these retinal layers in the living human eye. Here, we present a noninvasive method to observe both structural and functional information. Adaptive optics optical coherence tomography (AO-OCT) is used to resolve the inner retinal cells in all three dimensions and novel post processing algorithms are applied to extract structure and physiology down to the cellular level. AO-OCT captured the 3D mosaic of individual ganglion cell somas, retinal nerve fiber bundles of micron caliber, and microglial cells, all in exquisite detail. Time correlation analysis of the AO-OCT videos revealed notable temporal differences between the principal layers of the inner retina. The GC layer was more dynamic than the nerve fiber and inner plexiform layers. At the cellular level, we applied a customized correlation method to individual GCL somas, and found a mean time constant of activity of 0.57 s and spread of +/-0.1 s suggesting a range of physiological dynamics even in the same cell type. Extending our method to slower dynamics (from minutes to one year), time-lapse imaging and temporal speckle contrast revealed appendage and soma motion of resting microglial cells at the retinal surface.

  16. Influence of Misalignment on High-Order Aberration Correction for Normal Human Eyes

    International Nuclear Information System (INIS)

    Hao-Xin, Zhao; Bing, Xu; Li-Xia, Xue; Yun, Dai; Qian, Liu; Xue-Jun, Rao

    2008-01-01

    Although a compensation device can correct aberrations of human eyes, the effect will be degraded by its misalignment, especially for high-order aberration correction. We calculate the positioning tolerance of correction device for high-order aberrations, and within what degree the correcting effect is better than low-order aberration (defocus and astigmatism) correction. With fixed certain misalignment within the positioning tolerance, we calculate the residual wavefront rms aberration of the first-6 to first-35 terms along with the 3rd-5th terms of aberrations corrected, and the combined first-13 terms of aberrations are also studied under the same quantity of misalignment. However, the correction effect of high-order aberrations does not meliorate along with the increase of the high-order terms under some misalignment, moreover, some simple combined terms correction can achieve similar result as complex combinations. These results suggest that it is unnecessary to correct too much the terms of high-order aberrations which are difficult to accomplish in practice, and gives confidence to correct high-order aberrations out of the laboratory

  17. Comparison of intraocular pressure measured by non-contact air puff versus Goldmann applanation tonometers in gas-filled vitrectomized eyes.

    Science.gov (United States)

    Patikulsila, Direk; Taweemankongsab, Srisuda; Ngamtipakorn, Supob

    2003-05-01

    To compare intraocular pressure (IOP) measured by two different instruments, air puff tonometer (APT) versus Goldmann applanation tonometer (GAT), in gas-filled vitrectomized eyes. Three-month, prospective, comparative trial. Thirty-eight patients (38 eyes), who underwent a pars plana vitrectomy (PPV) with gas injection, were enrolled in the study. The IOP was measured by an APT, followed by GAT within 10 minutes by two different, masked investigators. IOPs were measured by two methods and then were compared. Overall, there was a high correlation between both measurements (r = 0.908, p 0.05). By a subgroup analysis of 17 eyes with IOP measured by a GAT of 21 mmHg or less, the APT readings (15.28 +/- 4.81) and GAT readings (14.47 +/- 3.89) were not significantly different (p > 0.05). Of 21 eyes, with IOP measured by a GAT of 22 mmHg or more, the APT readings (26.88 +/- 8.81) were significantly lower than those obtained by the GAT (29.62 +/- 7.69) (p < 0.05). In gas-filled vitrectomized eyes, IOP measurements obtained by an APT correlated well with those obtained by GAT, especially when the IOP was within normal range. However, in eyes with elevated IOP, the APT significantly underestimated the IOP measurement when compared to the gold standard, GAT.

  18. The effects of radiant cooling versus convective cooling on human eye tear film stability and blinking rate

    DEFF Research Database (Denmark)

    Nygaard, Linette; Uth, Simon C.; Bolashikov, Zhecho Dimitrov

    2014-01-01

    The effect of indoor temperature, radiant and convective cooling on tear film stability and eye blink frequency was examined. 24 human subjects were exposed to the non-uniform environment generated by localised chilled beam and a chilled ceiling combined with overhead mixing ventilation. The subj......The effect of indoor temperature, radiant and convective cooling on tear film stability and eye blink frequency was examined. 24 human subjects were exposed to the non-uniform environment generated by localised chilled beam and a chilled ceiling combined with overhead mixing ventilation....... The subjects participated in four two-hour experiments. The room air temperature was kept at 26 °C or 28 °C. Tear film samples were collected after 30 min of acclimatisation and at the end of the exposures. Eye blinking frequency was analysed for the first and last 15 min of each exposure. The tear film...... stability decreased as the temperature increased. The highest number of subjects with unchanged or improved tear film quality was observed with the localised chilled beam at 26 °C. A trend was found between subjects who reported eye irritation and had a bad tear film quality....

  19. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... about the members of the eye-care team . Consumer warning about the improper use of colored contact ... About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of ...

  20. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... about the members of the eye-care team . Consumer warning about the improper use of colored contact ... a laser pointer several times, according to a report published this month in the New England Journal ...

  1. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... lentes de contacto de color Sep. 26, 2013 It started as an impulsive buy from a souvenir ... Can Ruin Vision Eye Makeup Safety In fact, it is illegal to sell colored contact lenses without ...

  2. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Ophthalmology/Strabismus Ocular Pathology/Oncology Oculoplastics/Orbit Refractive Management/Intervention Retina/Vitreous Uveitis Focus ... Eye Health A-Z Symptoms Glasses & Contacts Tips & ...

  3. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... the United States. All contact lenses are medical devices that require a prescription and proper fitting by ... Care Apr 23, 2018 How long does it take the eye to go back to its original ...

  4. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... about the members of the eye-care team . Consumer warning about the improper use of colored contact ...

  5. Apnea-induced rapid eye movement sleep disruption impairs human spatial navigational memory.

    Science.gov (United States)

    Varga, Andrew W; Kishi, Akifumi; Mantua, Janna; Lim, Jason; Koushyk, Viachaslau; Leibert, David P; Osorio, Ricardo S; Rapoport, David M; Ayappa, Indu

    2014-10-29

    Hippocampal electrophysiology and behavioral evidence support a role for sleep in spatial navigational memory, but the role of particular sleep stages is less clear. Although rodent models suggest the importance of rapid eye movement (REM) sleep in spatial navigational memory, a similar role for REM sleep has never been examined in humans. We recruited subjects with severe obstructive sleep apnea (OSA) who were well treated and adherent with continuous positive airway pressure (CPAP). Restricting CPAP withdrawal to REM through real-time monitoring of the polysomnogram provides a novel way of addressing the role of REM sleep in spatial navigational memory with a physiologically relevant stimulus. Individuals spent two different nights in the laboratory, during which subjects performed timed trials before and after sleep on one of two unique 3D spatial mazes. One night of sleep was normally consolidated with use of therapeutic CPAP throughout, whereas on the other night, CPAP was reduced only in REM sleep, allowing REM OSA to recur. REM disruption via this method caused REM sleep reduction and significantly fragmented any remaining REM sleep without affecting total sleep time, sleep efficiency, or slow-wave sleep. We observed improvements in maze performance after a night of normal sleep that were significantly attenuated after a night of REM disruption without changes in psychomotor vigilance. Furthermore, the improvement in maze completion time significantly positively correlated with the mean REM run duration across both sleep conditions. In conclusion, we demonstrate a novel role for REM sleep in human memory formation and highlight a significant cognitive consequence of OSA. Copyright © 2014 the authors 0270-6474/14/3414571-07$15.00/0.

  6. MicroRNA Profiling in Aqueous Humor of Individual Human Eyes by Next-Generation Sequencing.

    Science.gov (United States)

    Wecker, Thomas; Hoffmeier, Klaus; Plötner, Anne; Grüning, Björn Andreas; Horres, Ralf; Backofen, Rolf; Reinhard, Thomas; Schlunck, Günther

    2016-04-01

    Extracellular microRNAs (miRNAs) in aqueous humor were suggested to have a role in transcellular signaling and may serve as disease biomarkers. The authors adopted next-generation sequencing (NGS) techniques to further characterize the miRNA profile in single samples of 60 to 80 μL human aqueous humor. Samples were obtained at the outset of cataract surgery in nine independent, otherwise healthy eyes. Four samples were used to extract RNA and generate sequencing libraries, followed by an adapter-driven amplification step, electrophoretic size selection, sequencing, and data analysis. Five samples were used for quantitative PCR (qPCR) validation of NGS results. Published NGS data on circulating miRNAs in blood were analyzed in comparison. One hundred fifty-eight miRNAs were consistently detected by NGS in all four samples; an additional 59 miRNAs were present in at least three samples. The aqueous humor miRNA profile shows some overlap with published NGS-derived inventories of circulating miRNAs in blood plasma with high prevalence of human miR-451a, -21, and -16. In contrast to blood, miR-184, -4448, -30a, -29a, -29c, -19a, -30d, -205, -24, -22, and -3074 were detected among the 20 most prevalent miRNAs in aqueous humor. Relative expression patterns of miR-451a, -202, and -144 suggested by NGS were confirmed by qPCR. Our data illustrate the feasibility of miRNA analysis by NGS in small individual aqueous humor samples. Intraocular cells as well as blood plasma contribute to the extracellular aqueous humor miRNome. The data suggest possible roles of miRNA in intraocular cell adhesion and signaling by TGF-β and Wnt, which are important in intraocular pressure regulation and glaucoma.

  7. About the Eye

    Medline Plus

    Full Text Available ... Contact Us Visiting the NIH Campus Mission Statement As part of the federal government’s National Institutes of ... Did You Know? Vision depends on your brain as much as it does on your eyes. NEI ...

  8. About the Eye

    Medline Plus

    Full Text Available ... NEI Women Scientists Advisory Committee (WSAC) Board of Scientific Counselors National Advisory Eye Council (NAEC) Donating to ... for the media Pressroom Contacts Dustin Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media ...

  9. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Ophthalmology/Strabismus Ocular Pathology/Oncology Oculoplastics/Orbit Refractive Management/Intervention Retina/Vitreous Uveitis ... Eye Health A-Z Symptoms Glasses & Contacts Tips & ...

  10. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye Care, Part 5 Mar 19, 2013 Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at the Academy Financial Relationships with Industry ...

  11. Characterization of the vitreous body of the human eye using a cyanine dye as a spectral and fluorescent probe

    Science.gov (United States)

    Panova, Ina G.; Tatikolov, Alexander S.

    2009-02-01

    We used one of cyanine dyes as a spectral and fluorescent probe in the study of the composition of the extracellular matrix of the human eye (its vitreous body). Owing to the unique ability of the dye to bind to collagens and human serum albumin, we revealed the simultaneous presence of both types of biomacromolecules in the vitreous body. The formation of the dye complex with human serum albumin leads to appearance of a long-wavelength absorption band (~612 nm) and a steep rise of fluorescence, whereas in the presence of collagens the dye forms J-aggregates with a longer-wavelength absorption band (640-660 nm) and moderate fluorescence. In this work we studied the composition of the human fetus vitreous body and its dynamics from 9 to 31 gestation weeks. On the basis of the data obtained by this method, we may assume that albumin, being a carrier protein, probably provides the vitreous body and surrounding tissues with necessary growth factors, hormones, lipids, vitamins, and some other biomolecules. The data show that the dye is promising not only for study of albumin functions in eye development, but also for characterization of some eye diseases and for analysis of other extracellular media.

  12. Phylogenetic analysis and victim contact tracing of rabies virus from humans and dogs in Bali, Indonesia.

    Science.gov (United States)

    Mahardika, G N K; Dibia, N; Budayanti, N S; Susilawathi, N M; Subrata, K; Darwinata, A E; Wignall, F S; Richt, J A; Valdivia-Granda, W A; Sudewi, A A R

    2014-06-01

    The emergence of human and animal rabies in Bali since November 2008 has attracted local, national and international interest. The potential origin and time of introduction of rabies virus to Bali is described. The nucleoprotein (N) gene of rabies virus from dog brain and human clinical specimens was sequenced using an automated DNA sequencer. Phylogenetic inference with Bayesian Markov Chain Monte Carlo (MCMC) analysis using the Bayesian Evolutionary Analysis by Sampling Trees (BEAST) v. 1.7.5 software confirmed that the outbreak of rabies in Bali was caused by an Indonesian lineage virus following a single introduction. The ancestor of Bali viruses was the descendant of a virus from Kalimantan. Contact tracing showed that the event most likely occurred in early 2008. The introduction of rabies into a large unvaccinated dog population in Bali clearly demonstrates the risk of disease transmission for government agencies and should lead to an increased preparedness and efforts for sustained risk reduction to prevent such events from occurring in future.

  13. Radiosensitivity of four human tumor xenografts. Influence of hypoxia and cell-cell contact

    International Nuclear Information System (INIS)

    Guichard, M.; Dertinger, H.; Malaise, E.P.

    1983-01-01

    Contact effect (CE) and hypoxia have been studied in human tumor cell lines transplanted in athymic nude mice. Four cell lines - one melanoma (Bell) and three colorectal adenocarcinomas (HT29, HRT18, and HCT8) - were studied. Cell survival was determined with an in vivo in vitro colony-forming assay. Survival curves were obtained under three different conditions: (1) tumor cells irradiated in air-breathing mice, (2) tumor cells irradiated in animals asphyxiated for 10 min, and (3) tumor cells plated and irradiated either immediately or 5 hr later. For all cell lines, radiosensitivity appeared to be lower when cells were irradiated in vivo than when they were irradiated in vitro. Only in the case of the HCT8 tumor did the relative in vivo radioresistance seem to be linked to hypoxia; in the other cell lines, hypoxia alone could not account for the lower in vivo radiosensitivity. Our results suggest that a CE plays an important role in the response of human xenografts to irradiation

  14. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. There is no such thing as a "one size fits all" contact lens. Lenses that are not properly fitted may scratch the eye or cause blood vessels to grow into the cornea. Even if you have perfect vision, you need to get an eye exam and a prescription ...

  15. Eye safety report 1 (dual wavelength). Human risk analysis simulator for space lidars

    International Nuclear Information System (INIS)

    Schulmeister, K.; Mellerio, J.; Sonneck, G.

    2001-09-01

    This report contains the results of a risk study for a satellite based lidar mission that uses two different laser wavelengths to measure atmospheric properties. A lidar can be considered as a laser radar and is an acronym for light detection and ranging. The lidar measures properties of the atmosphere by analysis of laser radiation that is directed back to the lidar. As only part of the laser radiation is scattered ir absorbed by the atmosphere, the remaining laser radiation emitted from the spacecraft is incident on the earth's surface, where it might lead to injuries, especially to the eye, if biological thresholds are exceeded. For the analysed mission there is no hazard to the skin, only a potential one to the eye. Because the footprint of the satellite's laser beam on the surface of the earth is so small and it moves so fast, the chance of the naked eye being exposed to the laser is small. Because of the magnification provided by an optical instrument, and the concomitant reduction in the field of view, the probability of exposure of an eye that is using such an instrument decreases with increasing optical power. However, because an increased optical power implies increased diameter of the light gathering optics, the laser energy delivered to an eye increases with instrument size so that if exposure did occur, the probability of delivering energy to the eye that exceeds the threshold for damage increases. There are thus two conflicting processes at work for viewing with optical instruments: an increase in diameter increases the energy delivered but reduces the probability of lidar beam interception. Energy delivered to the eye is such that damage thresholds will not be exceeded for naked eye viewing or for the use of small optical instruments. Exposure via telescopes with diameter larger than 12 cm could result in retinal damage of the exposed eye. (author)

  16. Finite element modeling for predicting the contact pressure between a foam mattress and the human body in a supine position.

    Science.gov (United States)

    Lee, Wookjin; Won, Byeong Hee; Cho, Seong Wook

    2017-01-01

    In this paper, we generated finite element (FE) models to predict the contact pressure between a foam mattress and the human body in a supine position. Twenty-year-old males were used for three-dimensional scanning to produce the FE human models, which was composed of skin and muscle tissue. A linear elastic isotropic material model was used for the skin, and the Mooney-Rivlin model was used for the muscle tissue because it can effectively represent the nonlinear behavior of muscle. The contact pressure between the human model and the mattress was predicted by numerical simulation. The human models were validated by comparing the body pressure distribution obtained from the same human subject when he was lying on two different mattress types. The experimental results showed that the slope of the lower part of the mattress caused a decrease in the contact pressure at the heels, and the effect of bone structure was most pronounced in the scapula. After inserting a simple structure to function as the scapula, the contact pressure predicted by the FE human models was consistent with the experimental body pressure distribution for all body parts. These results suggest that the models proposed in this paper will be useful to researchers and designers of products related to the prevention of pressure ulcers.

  17. Eye position signals modify vestibulo- and cervico-ocular fast phases during passive yaw rotations in humans.

    Science.gov (United States)

    Anastasopoulos, D; Mandellos, D; Kostadima, V; Pettorossi, V E

    2002-08-01

    We studied the amplitude, latency, and probability of occurrence of fast phases (FP) in darkness to unpredictable vestibular and/or cervical yaw stimulation in normal human subjects. The rotational stimuli were smoothed trapezoidal motion transients of 14 degrees amplitude and 1.25 s duration. Eye position before stimulus application (initial eye position, IEP) was introduced as a variable by asking the subjects to fixate a spot appearing either straight ahead or at 7 degrees eccentric positions. The recordings demonstrated that the generation of FP during vestibular stimulation was facilitated when the whole-body rotation was directed opposite the eccentric IEP. Conversely, FP were attenuated if the whole-body rotation was directed toward the eccentric IEP; i.e., the FP attenuated if they were made to further eccentric positions. Cervical stimulation-induced FP were small and variable in direction when IEP was directed straight ahead before stimulus onset. Eccentric IEPs resulted in large FP, the direction of which was essentially independent of the neck-proprioceptive stimulus. They tended to move the eye toward the primary position, both when the trunk motion under the stationary head was directed toward or away from the IEP. FP dependence on IEP was evident also during head-on-trunk rotations. No consistent interaction between vestibularly and cervically induced FP was found. We conclude that extraretinal eye position signals are able to modify vestibularly evoked reflexive FP in darkness, aiming at minimizing excursions of the eyes away from the primary position. However, neck-induced FP do not relate to specific tasks of stabilization or visual search. By keeping the eyes near the primary position, FP may permit flexibility of orienting responses to incoming stimuli. This recentering bias for both vestibularly and cervically generated FP may represent a visuomotor optimizing strategy.

  18. About the Eye

    Medline Plus

    Full Text Available ... Learn how the different parts of your eye work together so you can see and make sense of the world around you. Did You Know? Vision depends on your brain as much as it does on your eyes. NEI Home Contact Us A-Z Site Map NEI on ...

  19. Human Response to Ductless Personalised Ventilation: Impact of Air Movement, Temperature and Cleanness on Eye Symptoms

    DEFF Research Database (Denmark)

    Dalewski, Mariusz; Fillon, Maelys; Bivolarova, Maria

    2013-01-01

    environment facially applied individually controlled air movement of room air, with or without local filtering, did not have significant impact on eye blink frequency and tear film quality. The local air movement and air cleaning resulted in increased eye blinking frequency and improvement of tear film......The performance of ductless personalized ventilation (DPV) in conjunction with displacement ventilation (DV) was studied in relation to peoples’ health, comfort and performance. This paper presents results on the impact of room air temperature, using of DPV and local air filtration on eye blink...

  20. CULTURAL DISPLAY RULES DRIVE EYE GAZE DURING THINKING.

    Science.gov (United States)

    McCarthy, Anjanie; Lee, Kang; Itakura, Shoji; Muir, Darwin W

    2006-11-01

    The authors measured the eye gaze displays of Canadian, Trinidadian, and Japanese participants as they answered questions for which they either knew, or had to derive, the answers. When they knew the answers, Trinidadians maintained the most eye contact, whereas Japanese maintained the least. When thinking about the answers to questions, Canadians and Trinidadians looked up, whereas Japanese looked down. Thus, for humans, gaze displays while thinking are at least in part culturally determined.

  1. Blue eye color in humans may be caused by a perfectly associated founder mutation in a regulatory element located within the HERC2 gene inhibiting OCA2 expression

    DEFF Research Database (Denmark)

    Eiberg, Hans; Troelsen, Jesper; Boyd, Mette

    2008-01-01

    The human eye color is a quantitative trait displaying multifactorial inheritance. Several studies have shown that the OCA2 locus is the major contributor to the human eye color variation. By linkage analysis of a large Danish family, we finemapped the blue eye color locus to a 166 Kbp region...... within the HERC2 gene. By association analyses, we identified two SNPs within this region that were perfectly associated with the blue and brown eye colors: rs12913832 and rs1129038. Of these, rs12913832 is located 21.152 bp upstream from the OCA2 promoter in a highly conserved sequence in intron 86...... founder mutation in an OCA2 inhibiting regulatory element as the cause of blue eye color in humans. In addition, an LOD score of Z = 4.21 between hair color and D14S72 was obtained in the large family, indicating that RABGGTA is a candidate gene for hair color....

  2. Thermoreceptive innervation of human glabrous and hairy skin: a contact heat evoked potential analysis.

    Science.gov (United States)

    Granovsky, Yelena; Matre, Dagfinn; Sokolik, Alexander; Lorenz, Jürgen; Casey, Kenneth L

    2005-06-01

    The human palm has a lower heat detection threshold and a higher heat pain threshold than hairy skin. Neurophysiological studies of monkeys suggest that glabrous skin has fewer low threshold heat nociceptors (AMH type 2) than hairy skin. Accordingly, we used a temperature-controlled contact heat evoked potential (CHEP) stimulator to excite selectively heat receptors with C fibers or Adelta-innervated AMH type 2 receptors in humans. On the dorsal hand, 51 degrees C stimulation produced painful pinprick sensations and 41 degrees C stimuli evoked warmth. On the glabrous thenar, 41 degrees C stimulation produced mild warmth and 51 degrees C evoked strong but painless heat sensations. We used CHEP responses to estimate the conduction velocities (CV) of peripheral fibers mediating these sensations. On hairy skin, 41 degrees C stimuli evoked an ultra-late potential (mean, SD; N wave latency: 455 (118) ms) mediated by C fibers (CV by regression analysis: 1.28 m/s, N=15) whereas 51 degrees C stimuli evoked a late potential (N latency: 267 (33) ms) mediated by Adelta afferents (CV by within-subject analysis: 12.9 m/s, N=6). In contrast, thenar responses to 41 and 51 degrees C were mediated by C fibers (average N wave latencies 485 (100) and 433 (73) ms, respectively; CVs 0.95-1.35 m/s by regression analysis, N=15; average CV=1.7 (0.41) m/s calculated from distal glabrous and proximal hairy skin stimulation, N=6). The exploratory range of the human and monkey palm is enhanced by the abundance of low threshold, C-innervated heat receptors and the paucity of low threshold AMH type 2 heat nociceptors.

  3. Neurophysiological aspects of eye and eyelid movements during blinking in humans

    NARCIS (Netherlands)

    Bour, L. J.; Aramideh, M.; de Visser, B. W.

    2000-01-01

    The neural relationships between eyelid movements and eye movements during spontaneous, voluntary, and reflex blinking in a group of healthy subjects were examined. Electromyographic (EMG) recording of the orbicularis oculi (OO) muscles was performed using surface electrodes. Concurrently,

  4. Eye safety report 2 (355 nm). Human risk analysis simulator for space lidars

    International Nuclear Information System (INIS)

    Schulmeister, K.; Mellerio, J.; Sonneck, G.

    2001-09-01

    This report contains the results of a risk study for a satellite based lidar mission that uses a laser in the ultraviolet wavelength range to measure atmospheric properties. A lidar can be considered as a laser radar and is an acronym for light detection and ranging. The lidar measures properties of the atmosphere by analysis of laser radiation that is directed back to the lidar. As only part of the laser radiation is scattered or absorbed by the atmosphere, the remaining laser radiation emitted from the spacecraft is incident on the earth's surface, where it might lead to injuries, especially to the eye, if biological thresholds are exceeded. For the analysed mission there is no hazard to the skin, only a potential one to the eye, but only if ocular exposure occurs with very large telescopes. The wavelength of the laser is 355 nm, which is absorbed by the cornea and lens of the eye. That is, it is not focussed onto the retina of the eye as, for instance, visible wavelengths, and therefore comparatively high levels of laser exposure, are needed to produce an injury in the lens and cornea. Because the footprint of the satellite's laser beam on the surface of the earth is so small and it moves so fast, the chance of the naked eye being exposed to the laser is small. Because of the magnification provided by an optical instrument, and the concomitant reduction in the field of view, the probability of exposure of an eye that is using such an instrument decreases with increasing optical power. However, because an increased optical power implies increased diameter of the light gathering optics, the laser energy delivered to an eye increases with instrument size so that if exposure did occur, the probability of delivering energy to the eye that exceeds the thresholds for damage increases. There are thus two conflicting processes at work for viewing with optical instruments: an increase in diameter increases the energy delivered but reduces the probability of lidar beam

  5. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... have given blind patients some functional vision, using human embryonic stem cells. Two blind patients regained enough sight to read again after getting stem cell implants in their damaged eyes. ... EyeSmart Resources for Professionals Link your website to EyeSmart Embed ...

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Thomas Steinemann, MD, professor of ophthalmology at Case Western Reserve University in Cleveland. "This is far from ... technologies aiming to fix failing eye parts with human-made versions. U.S. News Highlights the Value of Ophthalmologists APR 20, ... EyeSmart Resources for Professionals Link your website to EyeSmart Embed ...

  7. Shared sensory estimates for human motion perception and pursuit eye movements.

    Science.gov (United States)

    Mukherjee, Trishna; Battifarano, Matthew; Simoncini, Claudio; Osborne, Leslie C

    2015-06-03

    Are sensory estimates formed centrally in the brain and then shared between perceptual and motor pathways or is centrally represented sensory activity decoded independently to drive awareness and action? Questions about the brain's information flow pose a challenge because systems-level estimates of environmental signals are only accessible indirectly as behavior. Assessing whether sensory estimates are shared between perceptual and motor circuits requires comparing perceptual reports with motor behavior arising from the same sensory activity. Extrastriate visual cortex both mediates the perception of visual motion and provides the visual inputs for behaviors such as smooth pursuit eye movements. Pursuit has been a valuable testing ground for theories of sensory information processing because the neural circuits and physiological response properties of motion-responsive cortical areas are well studied, sensory estimates of visual motion signals are formed quickly, and the initiation of pursuit is closely coupled to sensory estimates of target motion. Here, we analyzed variability in visually driven smooth pursuit and perceptual reports of target direction and speed in human subjects while we manipulated the signal-to-noise level of motion estimates. Comparable levels of variability throughout viewing time and across conditions provide evidence for shared noise sources in the perception and action pathways arising from a common sensory estimate. We found that conditions that create poor, low-gain pursuit create a discrepancy between the precision of perception and that of pursuit. Differences in pursuit gain arising from differences in optic flow strength in the stimulus reconcile much of the controversy on this topic. Copyright © 2015 the authors 0270-6474/15/358515-16$15.00/0.

  8. Dwarf Eye Disorder

    Science.gov (United States)

    Science Teacher, 2005

    2005-01-01

    Johns Hopkins researchers at the Wilmer Eye Institute have discovered what appears to be the first human gene mutation that causes extreme farsightedness. The researchers report that nanophthalmos, Greek for "dwarf eye," is a rare, potentially blinding disorder caused by an alteration in a gene called MFRP that helps control eye growth and…

  9. Eye Allergies

    Science.gov (United States)

    ... Español Eye Health / Eye Health A-Z Eye Allergies Sections What Are Eye Allergies? Eye Allergy Symptoms ... allergy diagnosis Eye allergy treatment What Are Eye Allergies? Leer en Español: ¿Qué son las alergias de ...

  10. Human rather than ape-like orbital morphology allows much greater lateral visual field expansion with eye abduction

    Science.gov (United States)

    Denion, Eric; Hitier, Martin; Levieil, Eric; Mouriaux, Frédéric

    2015-01-01

    While convergent, the human orbit differs from that of non-human apes in that its lateral orbital margin is significantly more rearward. This rearward position does not obstruct the additional visual field gained through eye motion. This additional visual field is therefore considered to be wider in humans than in non-human apes. A mathematical model was designed to quantify this difference. The mathematical model is based on published computed tomography data in the human neuro-ocular plane (NOP) and on additional anatomical data from 100 human skulls and 120 non-human ape skulls (30 gibbons; 30 chimpanzees / bonobos; 30 orangutans; 30 gorillas). It is used to calculate temporal visual field eccentricity values in the NOP first in the primary position of gaze then for any eyeball rotation value in abduction up to 45° and any lateral orbital margin position between 85° and 115° relative to the sagittal plane. By varying the lateral orbital margin position, the human orbit can be made “non-human ape-like”. In the Pan-like orbit, the orbital margin position (98.7°) was closest to the human orbit (107.1°). This modest 8.4° difference resulted in a large 21.1° difference in maximum lateral visual field eccentricity with eyeball abduction (Pan-like: 115°; human: 136.1°). PMID:26190625

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... eye-care professional. Retailers that sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. "Many of the lenses found online or in beauty salons, novelty shops or in pop-up ... contact lenses from a retailer that does not ask for a prescription. ...

  12. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Get follow up exams with your eye care provider. If you notice redness, swelling, excessive discharge, pain or discomfort from wearing contact lenses, remove the lenses and seek immediate medical attention from an ophthalmologist. Related resources: Learn how to properly care for contact lenses . ...

  13. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... eye-care team . Consumer warning about the improper use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses you are considering buying approved by the FDA? Check the FDA's database of approved contact lenses . Related Stories Prevent Infection ...

  14. Clonogenic growth of human breast cancer cells co-cultured in direct contact with serum-activated fibroblasts

    International Nuclear Information System (INIS)

    Samoszuk, Michael; Tan, Jenny; Chorn, Guillaume

    2005-01-01

    Accumulating evidence suggests that fibroblasts play a pivotal role in promoting the growth of breast cancer cells. The objective of the present study was to characterize and validate an in vitro model of the interaction between small numbers of human breast cancer cells and human fibroblasts. We measured the clonogenic growth of small numbers of human breast cancer cells co-cultured in direct contact with serum-activated, normal human fibroblasts. Using DNA microarrays, we also characterized the gene expression profile of the serum-activated fibroblasts. In order to validate the in vivo relevance of our experiments, we then analyzed clinical samples of metastatic breast cancer for the presence of myofibroblasts expressing α-smooth muscle actin. Clonogenic growth of human breast cancer cells obtained directly from in situ and invasive tumors was dramatically and consistently enhanced when the tumor cells were co-cultured in direct contact with serum-activated fibroblasts. This effect was abolished when the cells were co-cultured in transwells separated by permeable inserts. The fibroblasts in our experimental model exhibited a gene expression signature characteristic of 'serum response' (i.e. myofibroblasts). Immunostaining of human samples of metastatic breast cancer tissue confirmed that myofibroblasts are in direct contact with breast cancer cells. Serum-activated fibroblasts promote the clonogenic growth of human breast cancer cells in vitro through a mechanism that involves direct physical contact between the cells. This model shares many important molecular and phenotypic similarities with the fibroblasts that are naturally found in breast cancers

  15. 21 CFR 886.5925 - Soft (hydrophilic) contact lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Soft (hydrophilic) contact lens. 886.5925 Section 886.5925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... against the cornea and adjacent limbal and scleral areas of the eye to correct vision conditions or act as...

  16. 21 CFR 886.5916 - Rigid gas permeable contact lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Rigid gas permeable contact lens. 886.5916 Section 886.5916 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... against the cornea of the eye to correct vision conditions. The device is made of various materials, such...

  17. Influence of the corneal optical zone on the point-spread function of the human eye

    Science.gov (United States)

    Rol, Pascal O.; Parel, Jean-Marie A.

    1992-08-01

    In refractive surgery, a number of surgical techniques have been developed to correct ametropia (refractive defaults) of the eye by changing the exterior shape of the cornea. Because the air-cornea interface makes up for about two thirds of the refractive power of the eye, a refractive correction can be obtained by a suitable reshaping of the cornea. Postoperatively, it is usually observed that the corneal region consists of two or more zones which are characterized by different optical parameters exhibiting in particular different focal distances. Under normal circumstances, only the central area of the cornea is involved in the formation of the retinal image. However, if part of the light entering the eye through peripheral portions of the cornea with refractive properties different from the central area can pass the pupil, an out-of-focus `ghost' image may be overlaid on the retina causing a blur. In such a case the resolution, and the contrast performance of the eye which is expected from a successful operation, may be reduced. This study is an attempt to quantify the vision blur as a function of the diameter of the central zone, i.e., the optical zone which is of importance for vision.

  18. Spherical and irregular aberrations are important for the optimal performance of the human eye

    NARCIS (Netherlands)

    Nio, YK; Jansonius, NM; Fidler, [No Value; Geraghty, E; Norrby, S; Kooijman, AC

    Contrast sensitivity measured psychophysically at different levels of defocus can be used to evaluate the eye optics. Possible parameters of spherical and irregular aberrations, e.g, relative modulation transfer (RMT), myopic shift, and depth of focus, can be determined from these measurements. The

  19. Eye-head stabilization mechanism for a humanoid robot tested on human inertial data

    DEFF Research Database (Denmark)

    Vannucci, Lorenzo; Falotico, Egidio; Tolu, Silvia

    2016-01-01

    they keep the image stationary on the retina. In this work we present the first complete model of eye-head stabilization based on the coordination of VCR and VOR. The model is provided with learning and adaptation capabilities based on internal models. Tests on a simulated humanoid platform replicating...

  20. Eye Irritation Test (EIT) for Hazard Identification of Eye Irritating Chemicals using Reconstructed Human Cornea-like Epithelial (RhCE) Tissue Model.

    Science.gov (United States)

    Kaluzhny, Yulia; Kandárová, Helena; d'Argembeau-Thornton, Laurence; Kearney, Paul; Klausner, Mitchell

    2015-08-23

    To comply with the Seventh Amendment to the EU Cosmetics Directive and EU REACH legislation, validated non-animal alternative methods for reliable and accurate assessment of ocular toxicity in man are needed. To address this need, we have developed an eye irritation test (EIT) which utilizes a three dimensional reconstructed human cornea-like epithelial (RhCE) tissue model that is based on normal human cells. The EIT is able to separate ocular irritants and corrosives (GHS Categories 1 and 2 combined) and those that do not require labeling (GHS No Category). The test utilizes two separate protocols, one designed for liquid chemicals and a second, similar protocol for solid test articles. The EIT prediction model uses a single exposure period (30 min for liquids, 6 hr for solids) and a single tissue viability cut-off (60.0% as determined by the MTT assay). Based on the results for 83 chemicals (44 liquids and 39 solids) EIT achieved 95.5/68.2/ and 81.8% sensitivity/specificity and accuracy (SS&A) for liquids, 100.0/68.4/ and 84.6% SS&A for solids, and 97.6/68.3/ and 83.1% for overall SS&A. The EIT will contribute significantly to classifying the ocular irritation potential of a wide range of liquid and solid chemicals without the use of animals to meet regulatory testing requirements. The EpiOcular EIT method was implemented in 2015 into the OECD Test Guidelines as TG 492.

  1. The role of the skin microrelief in the contact behaviour of human skin: contact between the human finger and regular surface textures

    NARCIS (Netherlands)

    van Kuilenburg, Julien; Masen, Marc Arthur; van der Heide, Emile

    2013-01-01

    The friction behaviour of the human fingerpad as a function of asperity geometry was investigated experimentally. Surface textures consisting of evenly distributed spherically tipped asperities were used for in vivo testing. Using analytical expressions, a multi-scale model was developed to explain

  2. Dose conversion coefficients for electron exposure of the human eye lens

    International Nuclear Information System (INIS)

    Behrens, R; Dietze, G; Zankl, M

    2009-01-01

    Recent epidemiological studies suggest a rather low dose threshold (below 0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimized and current dose limits for the eye lens may be reduced in the future. Two questions arise from this situation: first, which dose quantity is related to the risk of developing a cataract, and second, which personal dose equivalent quantity is appropriate for monitoring this dose quantity. While the dose equivalent quantity H p (0.07) has often been seen as being sufficiently accurate for monitoring the dose to the lens of the eye, this would be questionable in the case when the dose limits were reduced and, thus, it may be necessary to generally use the dose equivalent quantity H p (3) for this purpose. The basis for a decision, however, must be the knowledge of accurate conversion coefficients from fluence to equivalent dose to the lens. This is especially important for low-penetrating radiation, for example, electrons. Formerly published values of conversion coefficients are based on quite simple models of the eye. In this paper, quite a sophisticated model of the eye including the inner structure of the lens was used for the calculations and precise conversion coefficients for electrons with energies between 0.2 MeV and 12 MeV, and for angles of radiation incidence between 0 deg. and 45 deg. are presented. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are up to 1000 times smaller for electron energies below 1 MeV, nearly equal at 1 MeV and above 4 MeV, and by a factor of 1.5 larger at about 1.5 MeV electron energy.

  3. RESEARCH OF LINEAR AND NONLINEAR PROCESSES AT FEMTOSECOND LASER RADIATION PROPAGATION IN THE MEDIUM SIMULATING THE HUMAN EYE VITREOUS

    Directory of Open Access Journals (Sweden)

    P. Y. Rogov

    2015-09-01

    Full Text Available The paper deals with mathematical model of linear and nonlinear processes occurring at the propagation of femtosecond laser pulses in the vitreous of the human eye. Methods of computing modeling are applied for the nonlinear spectral equation solution describing the dynamics of a two-dimensional TE-polarized radiation in a homogeneous isotropic medium with cubic fast-response nonlinearity without the usage of slowly varying envelope approximation. Environments close to the optical media parameters of the eye were used for the simulation. The model of femtosecond radiation propagation takes into account the process dynamics for dispersion broadening of pulses in time and the occurence of the self-focusing near the retina when passing through the vitreous body of the eye. Dependence between the pulse duration on the retina has been revealed and the duration of the input pulse and the values of power density at which there is self-focusing have been found. It is shown that the main mechanism of radiation damage with the use of titanium-sapphire laser is photoionization. The results coincide with those obtained by the other scientists, and are usable for creation Russian laser safety standards for femtosecond laser systems.

  4. Setting targets for human resources for eye health in sub-Saharan Africa: what evidence should be used?

    Science.gov (United States)

    Courtright, Paul; Mathenge, Wanjiku; Kello, Amir Bedri; Cook, Colin; Kalua, Khumbo; Lewallen, Susan

    2016-03-16

    With a global target set at reducing vision loss by 25% by the year 2019, sub-Saharan Africa with an estimated 4.8 million blind persons will require human resources for eye health (HReH) that need to be available, appropriately skilled, supported, and productive. Targets for HReH are useful for planning, monitoring, and resource mobilization, but they need to be updated and informed by evidence of effectiveness and efficiency. Supporting evidence should take into consideration (1) ever-changing disease-specific issues including the epidemiology, the complexity of diagnosis and treatment, and the technology needed for diagnosis and treatment of each condition; (2) the changing demands for vision-related services of an increasingly urbanized population; and (3) interconnected health system issues that affect productivity and quality. The existing targets for HReH and some of the existing strategies such as task shifting of cataract surgery and trichiasis surgery, as well as the scope of eye care interventions for primary eye care workers, will need to be re-evaluated and re-defined against such evidence or supported by new evidence.

  5. The effect of gaze angle on the evaluations of SAR and temperature rise in human eye under plane-wave exposures from 0.9 to 10 GHz

    International Nuclear Information System (INIS)

    Diao, Yinliang; Leung, Sai-Wing; Sun, Weinong; Siu, Yun-Ming; Kong, Richard; Hung Chan, Kwok

    2016-01-01

    This article investigates the effect of gaze angle on the specific absorption rate (SAR) and temperature rise in human eye under electromagnetic exposures from 0.9 to 10 GHz. Eye models in different gaze angles are developed based on bio-metric data. The spatial-average SARs in eyes are investigated using the finite-difference time-domain method, and the corresponding maximum temperature rises in lens are calculated by the finite-difference method. It is found that the changes in the gaze angle produce a maximum variation of 35, 12 and 20 % in the eye-averaged SAR, peak 10 g average SAR and temperature rise, respectively. Results also reveal that the eye-averaged SAR is more sensitive to the changes in the gaze angle than peak 10 g average SAR, especially at higher frequencies. (authors)

  6. Three-dimensional ray tracing in spherical and elliptical generalized Luneburg lenses for application in the human eye lens.

    Science.gov (United States)

    Gómez-Correa, J E; Coello, V; Garza-Rivera, A; Puente, N P; Chávez-Cerda, S

    2016-03-10

    Ray tracing in spherical Luneburg lenses has always been represented in 2D. All propagation planes in a 3D spherical Luneburg lens generate the same ray tracing, due to its radial symmetry. A geometry without radial symmetry generates a different ray tracing. For this reason, a new ray tracing method in 3D through spherical and elliptical Luneburg lenses using 2D methods is proposed. The physics of the propagation is shown here, which allows us to make a ray tracing associated with a vortex beam. A 3D ray tracing in a composite modified Luneburg lens that represents the human eye lens is also presented.

  7. Olhar e contato ocular: desenvolvimento típico e comparação na Síndrome de Down Gaze and eye contact: typical development and comparison in Down syndrome

    Directory of Open Access Journals (Sweden)

    Aline Elise Gerbelli Belini

    2008-03-01

    Full Text Available OBJETIVO: Investigar o desenvolvimento do olhar e do contato ocular em bebê portadora de síndrome de Down, comparando a freqüência de seu olhar para diferentes alvos ao comportamento visual de bebês em desenvolvimento típico. MÉTODOS: Um bebê, do gênero feminino, portador de Síndrome de Down, sem distúrbios visuais diagnosticados até a conclusão da coleta, e 17 bebês em desenvolvimento típico, foram filmados mensal e domiciliarmente, em interação livre com suas mães, do primeiro ao quinto mês de vida. Foi contabilizada a freqüência do olhar dirigido a 11 alvos, entre eles "olhar para os olhos da mãe". RESULTADOS: Os bebês em desenvolvimento típico apresentaram evolução estatisticamente significante, ao longo do período, nas freqüências de "olhos fechados" e de seu olhar para "objetos", "a pesquisadora", "o ambiente", "o próprio corpo", "o rosto da mãe" e "os olhos da mãe". Houve estabilidade estatística da amostra em "olhar para outra pessoa", "olhar para o corpo da mãe" e "abrir e fechar os olhos". O desenvolvimento do olhar e do contato ocular ocorreu de forma estatisticamente muito semelhante no bebê com síndrome de Down, em comparação com as médias dos demais bebês (teste qui-quadrado e com sua variabilidade individual (análise por aglomerados significativos. CONCLUSÕES: A interação precoce entre o bebê e sua mãe parece interferir mais na comunicação não-verbal da dupla do que limitações geneticamente influenciadas. Isto pode ter refletido nas semelhanças encontradas entre o desenvolvimento do comportamento e do contato visuais no bebê com síndrome de Down e nas crianças sem alterações de desenvolvimento.PURPOSE: To assess gaze and eye contact development of a baby girl with Down syndrome and to compare the frequency of gaze directed to different targets to that of babies with normal development. METHODS: A female baby with Down syndrome, without any detected eye conditions and 17

  8. Lens oscillations in the human eye. Implications for post-saccadic suppression of vision.

    Directory of Open Access Journals (Sweden)

    Juan Tabernero

    Full Text Available The eye changes gaze continuously from one visual stimulus to another. Using a high speed camera to record eye and lens movements we demonstrate how the crystalline lens sustains an inertial oscillatory decay movement immediately after every change of gaze. This behavior fit precisely with the movement of a classical damped harmonic oscillator. The time course of the oscillations range from 50 to 60 msec with an oscillation frequency of around 20 Hz. That has dramatic implications on the image quality at the retina on the very short times (∼50 msec that follow the movement. However, it is well known that our vision is nearly suppressed on those periods (post-saccadic suppression. Both phenomenon follow similar time courses and therefore might be synchronized to avoid the visual impairment.

  9. Ultrastructural effects of silicone oil on the clear crystalline lens of the human eye.

    Science.gov (United States)

    Soliman, Wael; Sharaf, Mohamed; Abdelazeem, Khaled; El-Gamal, Dalia; Nafady, Allam

    2018-03-01

    To evaluate light and electron microscopic changes of the anterior capsule and its epithelium after clear lens extraction of vitrectomized myopic eyes with silicone oil tamponade. This prospective, controlled, non-randomized, interventional study included 20 anterior lens capsular specimens that were excised during combined clear lens extraction and silicone oil removal from previously vitrectomized highly myopic patients with silicone oil tamponade for previous retinal detachment surgeries. The specimens were examined via light microscopy and electron microscopy and compared with 20 anterior capsule specimens removed during clear lens extraction of non-vitrectomized highly myopic eyes. Light microscopic examination of clear lens anterior capsule specimens of vitrectomized myopic eyes filled with silicone oil showed relatively more flat cells with irregular outline of lens' epithelial cells with wide intercellular spaces, deeply stained nuclei, and multiple intracytoplasmic vacuoles. Scanning electron microscopy revealed collagenous surfaces filled with multiple pits, depressions, and abnormal deposits. Transmission electron microscopy revealed lens epithelial cells with apoptotic changes, many cytoplasmic vacuoles, and filopodia-like protrusions between lens epithelial cells and the capsule. Epithelial proliferation and multilayering were also observed. silicone oil may play a role in the development of apoptotic and histopathological changes in clear lens epithelial cells. Clarity of the lens at the time of silicone oil removal does not indicate an absence of cataractous changes. We found justification of combined clear lens extraction and silicone oil removal or combined phacovitrectomy when silicone oil injection is planned, but further long-term studies with larger patient groups are required.

  10. Establishment of a new in vitro test method for evaluation of eye irritancy using a reconstructed human corneal epithelial model, LabCyte CORNEA-MODEL.

    Science.gov (United States)

    Katoh, Masakazu; Hamajima, Fumiyasu; Ogasawara, Takahiro; Hata, Ken-ichiro

    2013-12-01

    Finding in vitro eye irritation testing alternatives to animal testing such as the Draize eye test, which uses rabbits, is essential from the standpoint of animal welfare. It has been developed a reconstructed human corneal epithelial model, the LabCyte CORNEA-MODEL, which has a representative corneal epithelium-like structure. Protocol optimization (pre-validation study) was examined in order to establish a new alternative method for eye irritancy evaluation with this model. From the results of the optimization experiments, the application periods for chemicals were set at 1min for liquid chemicals or 24h for solid chemicals, and the post-exposure incubation periods were set at 24h for liquids or zero for solids. If the viability was less than 50%, the chemical was judged to be an eye irritant. Sixty-one chemicals were applied in the optimized protocol using the LabCyte CORNEA-MODEL and these results were evaluated in correlation with in vivo results. The predictions of the optimized LabCyte CORNEA-MODEL eye irritation test methods were highly correlated with in vivo eye irritation (sensitivity 100%, specificity 80.0%, and accuracy 91.8%). These results suggest that the LabCyte CORNEA-MODEL eye irritation test could be useful as an alternative method to the Draize eye test. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... have given blind patients some functional vision, using human embryonic stem cells. Two blind patients regained enough ... technologies aiming to fix failing eye parts with human-made versions. U.S. News Highlights the Value of ...

  12. Enhanced expression of IL-8 in normal human keratinocytes and human keratinocyte cell line HaCaT in vitro after stimulation with contact sensitizers, tolerogens and irritants.

    Science.gov (United States)

    Mohamadzadeh, M; Müller, M; Hultsch, T; Enk, A; Saloga, J; Knop, J

    1994-12-01

    To investigate the interleukin-8 production of keratinocytes after stimulation in vitro we have used various agents: (i) contact sensitizer (2,4-dinitrofluorobenzene, 3-n-pentadecylcatechol); (ii) tolerogen (5-methyl-3-n-pentadecylcatechol); (iii) irritant (sodium lauryl sulfate). Interleukin-8 gene expression was assessed by northern blot hybridization of the total cytoplasmic RNA extracted from subconfluent normal human keratinocyte cultures and the keratinocyte cell line HaCaT using a radiolabeled DNA probe specific for human interleukin-8. Interleukin-8 gene expression was markedly increased upon in vitro stimulation after 1-6 h with contact sensitizers, tolerogen and the irritant. In contrast, interleukin-8 production was not detectable in unstimulated normal human keratinocytes or the HaCaT keratinocyte cell line. These results suggest that the induction and production of interleukin-8 is a response to nonspecific stimuli and may play a critical role in the early response to immunogenic or inflammatory signals in man.

  13. Keep Contacts Clean (A Cup of Health with CDC)

    Centers for Disease Control (CDC) Podcasts

    Contact lenses can be a comfortable and convenient alternative to traditional eye glasses, but without proper care, they can cause severe eye problems. In this podcast, Sarah Collier discusses the importance of proper maintenance of contact lenses.

  14. Conflicting selective forces affect T cell receptor contacts in an immunodominant human immunodeficiency virus epitope

    DEFF Research Database (Denmark)

    Iversen, Astrid K N; Stewart-Jones, Guillaume; Learn, Gerald H

    2006-01-01

    two principal, diametrically opposed evolutionary pathways that exclusively affect T cell-receptor contact residues. One pathway was characterized by acquisition of CTL escape mutations and the other by selection for wild-type amino acids. The pattern of CTL responses to epitope variants shaped which...

  15. Putin, Bush issue statement on advancing US-Russian human contacts

    CERN Multimedia

    2002-01-01

    "In addition to interstate, bilateral, regional and global issues discussed by Russian President Vladimir Putin and US President George Bush during their Kremlin summit on 24 May, the two leaders considered issues related to people-to-people contacts, ties between cities, states and regions, institutions and organizations" (1 page).

  16. Ocular surface area and human eye blink frequency during VDU work

    DEFF Research Database (Denmark)

    Nielsen, Pernille Kofoed; Søgaard, Karen; Skotte, Jørgen

    2008-01-01

    . The low BF during the active task was succeded by a burst with high BF after cessation of the active task, indicating a compensatory blinking process. This stresses that interchange of work tasks with different cognitive load is as important as the monitor position in the prevention of visual......The purpose of this study was to investigate how the ocular surface area (OSA) and the eye blink frequency (BF) are affected by a high versus a low-monitor position during visual display unit (VDU) work with varying cognitive demands. In a balanced randomized (2 x 2) design ten healthy subjects...

  17. Human eye cataract microstructure modeling and its effect on simulated retinal imaging

    Science.gov (United States)

    Fan, Wen-Shuang; Chang, Chung-Hao; Horng, Chi-Ting; Yao, Hsin-Yu; Sun, Han-Ying; Huang, Shu-Fang; Wang, Hsiang-Chen

    2017-02-01

    We designed a crystalline microstructure during cataract lesions and calculated the aberration value of the eye by using ray trace modeling to identify the corresponding spherical aberration, coma aberration, and trefoil aberration value under different pathological-change degrees. The mutual relationship between microstructure and aberration was then discussed using these values. Calculation results showed that with increased layer number of microstructure, the influence of aberration value on spherical aberration was the greatest. In addition, the influence of a relatively compact microstructure on spherical aberration and coma aberration was small, but that on trefoil aberration was great.

  18. Identification of cornifelin and early growth response-1 gene as novel biomarkers for in vitro eye irritation using a 3D reconstructed human cornea model MCTT HCE™.

    Science.gov (United States)

    Choi, Seunghye; Lee, Miri; Lee, Su-Hyon; Jung, Haeng-Sun; Kim, Seol-Yeong; Chung, Tae-Young; Choe, Tae-boo; Chun, Young-Jin; Lim, Kyung-Min

    2015-09-01

    Evaluation of the eye irritation is essential in the development of new cosmetic products. Draize rabbit eye irritation test has been widely used in which chemicals are directly applied to rabbit eye, and the symptoms and signs of eyes are scored. However, due to the invasive procedure, it causes substantial pain and discomfort to animals. Recently, we reported in vitro eye irritation test method using a 3D human corneal epithelial model (MCTT HCE™) which is reconstructed from remaining human tissues after a corneal transplantation. This model exhibited an excellent predictive capacity for 25 reference chemicals (sensitivity 100%, specificity 77% and accuracy 88% vs. GHS). To improve the test performance, we explored new biomarkers for the eye irritation through transcriptomic approach. Three surfactants were selected as model eye irritants that include sodium lauryl sulfate, benzalkonium chloride and triton X-100. After test chemicals were treated, we investigated differentially expressed genes through a whole-gene microarray (Affymetrix GeneChip(®) Human Gene 2.0 ST Array, 48,000 probes). As a result, we identified that mRNAs of cornifelin (CNFN), a constituent of the insoluble cornified cell envelope of stratified squamous epithelia, and early growth response-1 (EGR1), a nuclear transcriptional regulator, were significantly up-regulated by all three irritants. Up-regulation of CNFN and EGR1 was further confirmed by Q-RT-PCR, and immunohistochemistry revealed increased level of CNFN in irritant-treated tissues, supporting the relevance of CNFN and EGR1 as new biomarkers for eye irritation.

  19. Automatic measurement of axial length of human eye using three-dimensional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Watanabe, Masaki; Kiryu, Tohru

    2011-01-01

    The measurement of axial length and the evaluation of three dimensional (3D) form of an eye are essential to evaluate the mechanism of myopia progression. We propose a method of automatic measurement of axial length including adjustment of the pulse sequence of short-term scan which could suppress influence of eyeblink, using a magnetic resonance imaging (MRI) which acquires 3D images noninvasively. Acquiring T 2 -weighted images with 3.0 tesla MRI device and eight-channel phased-array head coil, we extracted left and right eye ball images, and then reconstructed 3D volume. The surface coordinates were calculated from 3D volume, fitting the ellipsoid model coordinates with the surface coordinates, and measured the axial length automatically. Measuring twenty one subjects, we compared the automatically measured values of axial length with the manually measured ones, then confirmed significant elongation in the axial length of myopia compared with that of emmetropia. Furthermore, there were no significant differences (P<0.05) between the means of automatic measurements and the manual ones. Accordingly, the automatic measurement process of axial length could be a tool for the elucidation of the mechanism of myopia progression, which would be suitable for evaluating the axial length easily and noninvasively. (author)

  20. Human Contacts and Potential Pathways of Disease Introduction on Georgia Poultry Farms

    DEFF Research Database (Denmark)

    Vieira, Antonio; Hofacre, C.L.; Smith, J.A.

    2009-01-01

    and spread of a highly infectious pathogen, such as the currently circulating H5N1 influenza virus, a survey was administered to growers in two counties in Georgia representing areas of low and high poultry densities. Survey questions regarding horizontal contacts and management were sent to commercial...... broiler and breeder-layer chicken producers. Responses were used to estimate and compare contact rates and patterns between the two regions. The distribution of high-risk visitors (i.e., those going inside the poultry houses) to poultry farms did not vary significantly between growers in counties...... county. Data obtained in this study support the observations of published poultry disease outbreak investigations and highlight the differences in farm vulnerability to disease introduction within areas of different poultry densities and management practices....

  1. Nasal Carriage of Staphylococcus intermedius in Humans in Contact with Dogs

    OpenAIRE

    Harvey, R. G.; Marples, R. R.; Noble, W. C.

    2011-01-01

    A study of staphylococci isolated from the anterior nares of 16 owners of dogs with atopic dermatitis and 13 veterinary practice staff in constant contact with dogs was conducted. There was one persistent nasal carrier and four transient nasal carriers of Staphylococcus intermedius. This carriage rate is higher than previously reported and presumably contributes to the presence of antibodies to S. intermedius in about 20 per cent of the normal population. Thus transfer of S. intermedius from ...

  2. Estimation of the in vitro eye irritating and inflammatory potential of lipopolysaccharide (LPS) and dust by using reconstituted human corneal epithelium tissue cultures.

    Science.gov (United States)

    Cao, Yi; Bindslev, Dorthe A; Kjærgaard, Søren K

    2015-01-01

    Eye irritation is a common complaint in indoor environment, but the causes have still not been identified among the multiple exposures in house environments. To identify the potential environmental factors responsible for eye irritation and study the possible mechanisms, an in vitro model for eye irritation is suggested. In this study, reconstituted human corneal epithelium (HCE) tissue cultures were used to study the eye irritating and inflammatory potential of lipopolysaccharide (LPS) and dust. HCE tissue cultures were exposed to a range of concentrations of LPS for 6 h and dust for 24 h, respectively. After exposure, viability and secretion of interleukins (IL) IL-1β, IL-8, and tumor necrosis factor (TNFα) were examined. Histology was used to indicate the morphological changes after dust exposure. Both LPS and dust affected HCE viability. There was an increased level of IL-8 after LPS exposure, while the concentrations of IL-1β and TNFα remained unaffected. Dust exposure resulted in an elevation of both IL-1β and IL-8, but not TNFα. Histology study showed increased vacuolization and reduced thickness after 24 h exposure to 5 mg/mL dust. LPS and dust showed in vitro eye irritating and inflammatory potential, and cytokines/chemokines like IL-1β and IL-8 may be involved in the mechanisms of eye irritation. The HCE tissue culture may be used as an in vitro model to study environmental exposure induced eye irritation and inflammation.

  3. The Effect of Scala Tympani Morphology on Basilar Membrane Contact With a Straight Electrode Array: A Human Temporal Bone Study.

    Science.gov (United States)

    Verberne, Juul; Risi, Frank; Campbell, Luke; Chambers, Scott; O'Leary, Stephen

    2017-01-01

    Scala tympani morphology influences the insertion dynamics and intra-scalar position of straight electrode arrays. Hearing preservation is the goal of cochlear implantation with current thin straight electrode arrays. These hug the lateral wall, facilitating full, atraumatic insertions. However, most studies still report some postoperative hearing loss. This study explores the influence of scala tympani morphology on array position relative to the basilar membrane and its possible contribution to postoperative hearing loss. Twenty-six fresh-frozen human temporal bones implanted with a straight electrode array were three-dimensionally reconstructed from micro-photographic histological sections. Insertion depth and the proximity between the array and basilar membrane were recorded. Lateral wall shape was quantified as a curvature ratio. Insertion depths ranged from 233 to 470 degrees. The mean first point of contact between the array and basilar membrane was 185 degrees; arrays tended to remain in contact with the membrane after first contacting it. Eighty-nine and 93% of arrays that reached the upper basal (>240-360 degrees) and second (>360-720 degrees) turns respectively contacted the basilar membrane in these regions. Scalar wall curvature ratio decreased significantly (the wall became steeper) from the basal to second turns. This shift correlated with a reduced distance between the array and basilar membrane. Scala tympani morphology influences the insertion dynamics and intra-scalar position of a straight electrode array. In addition to gross trauma of cochlear structures, contact between the array and basilar membrane and how this impacts membrane function should be considered in hearing preservation cases.

  4. Relative size of the eye and orbit: an evolutionary and craniofacial constraint model for examining the etiology and disparate incidence of juvenile-onset myopia in humans.

    Science.gov (United States)

    Masters, Michael P

    2012-05-01

    The principal aim of this research is to provide a new model for investigating myopia in humans, and contribute to an understanding of the degree to which modern variation and evolutionary change in orbital and overall craniofacial morphology may help explain the common eye form association with this condition. Recent research into long and short-term evolution of the human orbit reveals a number of changes in this feature, and particularly since the Upper Paleolithic. These include a reduction in orbital depth, a decrease in anterior projection of the upper and lower orbital margins, and most notably, a reduction in orbital volume since the Holocene in East Asia. Reduced orbital volume in this geographic region could exacerbate an existing trend in recent hominin evolution toward larger eyes in smaller orbits, and may help explain the unusually high frequency of myopia in East Asian populations. The objective of the current study is to test a null hypothesis of no relationship between a ratio of orbit to eye volume and spherical equivalent refractive error (SER) in a sample of Chinese adults, and examine how relative size of the eye within the orbit relates to SER between the sexes and across the sample population. Analysis of the orbit, eye, and SER reveals a strong relationship between relative size of the eye within the orbit and the severity of myopic refractive error. An orbit/eye ratio of 3 for females and 3.5 for males (or an eye that occupies approximately 34% and 29% of the orbit, respectively), designates a clear threshold at which myopia develops, and becomes progressively worse as the eye continues to occupy a greater proportion of the orbital cavity. These results indicate that relative size of the eye within the orbit is an important factor in the development of myopia, and suggests that individuals with large eyes in small orbits lack space for adequate development of ocular tissues, leading to compression and distortion of the lithesome globe

  5. Animal Ownership and Touching Enrich the Context of Social Contacts Relevant to the Spread of Human Infectious Diseases.

    Science.gov (United States)

    Kifle, Yimer Wasihun; Goeyvaerts, Nele; Van Kerckhove, Kim; Willem, Lander; Kucharski, Adam; Faes, Christel; Leirs, Herwig; Hens, Niel; Beutels, Philippe

    2015-01-01

    Many human infectious diseases originate from animals or are transmitted through animal vectors. We aimed to identify factors that are predictive of ownership and touching of animals, assess whether animal ownership influences social contact behavior, and estimate the probability of a major zoonotic outbreak should a transmissible influenza-like pathogen be present in animals, all in the setting of a densely populated European country. A diary-based social contact survey (n = 1768) was conducted in Flanders, Belgium, from September 2010 until February 2011. Many participants touched pets (46%), poultry (2%) or livestock (2%) on a randomly assigned day, and a large proportion of participants owned such animals (51%, 15% and 5%, respectively). Logistic regression models indicated that larger households are more likely to own an animal and, unsurprisingly, that animal owners are more likely to touch animals. We observed a significant effect of age on animal ownership and touching. The total number of social contacts during a randomly assigned day was modeled using weighted-negative binomial regression. Apart from age, household size and day type (weekend versus weekday and regular versus holiday period), animal ownership was positively associated with the total number of social contacts during the weekend. Assuming that animal ownership and/or touching are at-risk events, we demonstrate a method to estimate the outbreak potential of zoonoses. We show that in Belgium animal-human interactions involving young children (0-9 years) and adults (25-54 years) have the highest potential to cause a major zoonotic outbreak.

  6. Direct contact with endoderm-like cells efficiently induces cardiac progenitors from mouse and human pluripotent stem cells.

    Directory of Open Access Journals (Sweden)

    Hideki Uosaki

    Full Text Available RATIONALE: Pluripotent stem cell-derived cardiac progenitor cells (CPCs have emerged as a powerful tool to study cardiogenesis in vitro and a potential cell source for cardiac regenerative medicine. However, available methods to induce CPCs are not efficient or require high-cost cytokines with extensive optimization due to cell line variations. OBJECTIVE: Based on our in-vivo observation that early endodermal cells maintain contact with nascent pre-cardiac mesoderm, we hypothesized that direct physical contact with endoderm promotes induction of CPCs from pluripotent cells. METHOD AND RESULT: To test the hypothesis, we cocultured mouse embryonic stem (ES cells with the endodermal cell line End2 by co-aggregation or End2-conditioned medium. Co-aggregation resulted in strong induction of Flk1(+ PDGFRa(+ CPCs in a dose-dependent manner, but the conditioned medium did not, indicating that direct contact is necessary for this process. To determine if direct contact with End2 cells also promotes the induction of committed cardiac progenitors, we utilized several mouse ES and induced pluripotent (iPS cell lines expressing fluorescent proteins under regulation of the CPC lineage markers Nkx2.5 or Isl1. In agreement with earlier data, co-aggregation with End2 cells potently induces both Nkx2.5(+ and Isl1(+ CPCs, leading to a sheet of beating cardiomyocytes. Furthermore, co-aggregation with End2 cells greatly promotes the induction of KDR(+ PDGFRa(+ CPCs from human ES cells. CONCLUSIONS: Our co-aggregation method provides an efficient, simple and cost-effective way to induce CPCs from mouse and human pluripotent cells.

  7. A human hemi-cornea model for eye irritation testing: quality control of production, reliability and predictive capacity.

    Science.gov (United States)

    Engelke, M; Zorn-Kruppa, M; Gabel, D; Reisinger, K; Rusche, B; Mewes, K R

    2013-02-01

    We have developed a 3-dimensional human hemi-cornea which comprises an immortalized epithelial cell line and keratocytes embedded in a collagen stroma. In the present study, we have used MTT reduction of the whole tissue to clarify whether the production of this complex 3-D-model is transferable into other laboratories and whether these tissues can be constructed reproducibly. Our results demonstrate the reproducible production of the hemi-cornea model according to standard operation procedures using 15 independent batches of reconstructed hemi-cornea models in two independent laboratories each. Furthermore, the hemi-cornea tissues have been treated with 20 chemicals of different eye-irritating potential under blind conditions to assess the performance and limitations of our test system comparing three different prediction models. The most suitable prediction model revealed an overall in vitro-in vivo concordance of 80% and 70% in the participating laboratories, respectively, and an inter-laboratory concordance of 80%. Sensitivity of the test was 77% and specificity was between 57% and 86% to discriminate classified from non-classified chemicals. We conclude that additional physiologically relevant endpoints in both epithelium and stroma have to be developed for the reliable prediction of all GHS classes of eye irritation in one stand alone test system. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Human regional cerebral blood flow during rapid-eye-movement sleep

    DEFF Research Database (Denmark)

    Madsen, P L; Holm, S; Vorstrup, S

    1991-01-01

    Owing to the coupling between CBF and neuronal activity, regional CBF is a reflection of neural activity in different brain regions. In this study we measured regional CBF during polysomnographically well-defined rapid-eye-movement (REM) sleep by the use of single photon emission computerized...... tomography and the new tracer 99mTc-dl-hexamethylpropyleneamine. Eleven healthy volunteers aged between 22 and 27 years were studied. CBF was measured on separate nights during REM sleep and during EEG-verified wakefulness. On awakening from REM sleep, all subjects reported visual dreams. During REM sleep...... dream experiences. On the other hand, the reduced involvement of the inferior frontal cortex observed during REM sleep might explain the poor temporal organization and bizarreness often experienced in dreams....

  9. Remifentanil inhibits rapid eye movement sleep but not the nocturnal melatonin surge in humans.

    Science.gov (United States)

    Bonafide, Christopher P; Aucutt-Walter, Natalie; Divittore, Nicole; King, Tonya; Bixler, Edward O; Cronin, Arthur J

    2008-04-01

    Postoperative patients are sleep deprived. Opioids, commonly administered for postoperative pain control, are often mistakenly considered inducers of naturally occurring sleep. This study describes the effect of the opioid remifentanil on nocturnal sleep in healthy volunteers. In addition, this study tests the hypothesis that opioid-induced sleep disturbance is caused by a circadian pacemaker disturbance, reflected by suppressed nocturnal plasma concentration of melatonin. Polysomnography was performed in 10 volunteers from 11:00 pm to 7:00 am for four nights at 6-day intervals. On two nights, remifentanil (0.01-0.04 microg x kg x min) was infused from 10:30 pm to 7:00 am, and either a placebo capsule or 3.0 mg melatonin was administered at 10:30 pm. On two additional nights, saline was infused, and the placebo or melatonin capsules were administered at 10:30 pm. Blood was drawn at 12:00 am, 3:00 am, and 6:00 am to measure the plasma concentration of melatonin and cortisol. A repeated-measures analysis of variance model was used to determine the effect of remifentanil on sleep stages, the effect of remifentanil on the plasma concentration of melatonin, and the effect of exogenous melatonin on remifentanil-induced sleep disturbance. Remifentanil inhibited rapid eye movement sleep (14.1 +/- 7.2% to 3.9 +/- 6.9%). The amount of slow wave sleep decreased from 6.8 +/- 7.6% to 3.2 +/- 6.1%, but this decrease was not statistically significant. Remifentanil did not decrease melatonin concentration. Melatonin administration did not prevent remifentanil-induced sleep disturbance. An overnight constant infusion of remifentanil inhibits rapid eye movement sleep without suppressing the nocturnal melatonin surge.

  10. Where, when and why do tsetse contact humans? Answers from studies in a national park of Zimbabwe.

    Directory of Open Access Journals (Sweden)

    Stephen J Torr

    Full Text Available BACKGROUND: Sleeping sickness, also called human African trypanosomiasis, is transmitted by the tsetse, a blood-sucking fly confined to sub-Saharan Africa. The form of the disease in West and Central Africa is carried mainly by species of tsetse that inhabit riverine woodland and feed avidly on humans. In contrast, the vectors for the East and Southern African form of the disease are usually savannah species that feed mostly on wild and domestic animals and bite humans infrequently, mainly because the odours produced by humans can be repellent. Hence, it takes a long time to catch many savannah tsetse from people, which in turn means that studies of the nature of contact between savannah tsetse and humans, and the ways of minimizing it, have been largely neglected. METHODOLOGY/PRINCIPAL FINDINGS: The savannah tsetse, Glossina morsitans morsitans and G. pallidipes, were caught from men in the Mana Pools National park of Zimbabwe. Mostly the catch consisted of young G. m. morsitans, with little food reserve. Catches were increased by 4-8 times if the men were walking, not stationary, and increased about ten times more if they rode on a truck at 10 km/h. Catches were unaffected if the men used deodorant or were baited with artificial ox odour, but declined by about 95% if the men were with an ox. Surprisingly, men pursuing their normal daily activities were bitten about as much when in or near buildings as when in woodland. Catches from oxen and a standard ox-like trap were poor indices of the number and physiological state of tsetse attacking men. CONCLUSION/SIGNIFICANCE: The search for new strategies to minimize the contact between humans and savannah tsetse should focus on that occurring in buildings and vehicles. There is a need to design a man-like trap to help to provide an index of sleeping sickness risk.

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... enough sight to read again after getting stem cell implants in their damaged eyes. Ocular Melanoma Cases Getting Nationwide Attention MAY 03, ... re edging closer, thanks to a wave of new technologies aiming to fix failing eye parts with human-made versions. U.S. News Highlights ...

  12. Numerical model of heat transfer in the human eye with consideration of fluid dynamics of the aqueous humour

    Energy Technology Data Exchange (ETDEWEB)

    Karampatzakis, Andreas; Samaras, Theodoros, E-mail: theosama@auth.g [Department of Physics, Aristotle University of Thessaloniki, GR-54124 Thessaloniki (Greece)

    2010-10-07

    In this work we present a new 3D numerical model for heat transfer in the human eye, which takes into account the aqueous humour flow in the anterior chamber. We show that consideration of this phenomenon in the calculations alters the temperature distribution on the corneal and lens surfaces, without, however, noticeably changing their absolute values. The most notable effect is that the coolest area of the cornea moves at a point of 2 mm inferior to its geometric centre. The maximum velocity of the fluid in the anterior chamber was found to be 3.36 x 10{sup -4} m s{sup -1}. The effect of the flow on displacing the cool area of the corneal surface temperature is counterbalanced by assuming anisotropic thermal conductivity. The model was implemented in the case of an artificial intraocular lens to show the resulting temperature variations.

  13. A teaser made simple: a didactic measurement of the spectral answer of a human-eye-calibrated lux meter

    International Nuclear Information System (INIS)

    Di Capua, R; Offi, F; Dell'Omo, M; Fontana, F

    2012-01-01

    A simple didactic experiment has been designed and realized, in order to illustrate to undergraduate students in scientific faculties some basic concepts lying behind the fundamentals of geometrical optics. The spectral response of a human-eye-calibrated lux meter was measured using a very trivial experimental arrangement. The white light of a halogen lamp was decomposed into its spectral components through a diffraction grating, so that collecting the radiation at different dispersion angles allowed one to measure the intensity as a function of wavelength. The experiment can be used to effectively illustrate the concepts of spectral distribution, the radiometry versus photometry conversion and photopic response, and the famous historical experience by Herschel on the ‘temperature of colours’. (paper)

  14. Numerical model of heat transfer in the human eye with consideration of fluid dynamics of the aqueous humour.

    Science.gov (United States)

    Karampatzakis, Andreas; Samaras, Theodoros

    2010-10-07

    In this work we present a new 3D numerical model for heat transfer in the human eye, which takes into account the aqueous humour flow in the anterior chamber. We show that consideration of this phenomenon in the calculations alters the temperature distribution on the corneal and lens surfaces, without, however, noticeably changing their absolute values. The most notable effect is that the coolest area of the cornea moves at a point of 2 mm inferior to its geometric centre. The maximum velocity of the fluid in the anterior chamber was found to be 3.36 × 10(-4) m s(-1). The effect of the flow on displacing the cool area of the corneal surface temperature is counterbalanced by assuming anisotropic thermal conductivity. The model was implemented in the case of an artificial intraocular lens to show the resulting temperature variations.

  15. Numerical model of heat transfer in the human eye with consideration of fluid dynamics of the aqueous humour

    International Nuclear Information System (INIS)

    Karampatzakis, Andreas; Samaras, Theodoros

    2010-01-01

    In this work we present a new 3D numerical model for heat transfer in the human eye, which takes into account the aqueous humour flow in the anterior chamber. We show that consideration of this phenomenon in the calculations alters the temperature distribution on the corneal and lens surfaces, without, however, noticeably changing their absolute values. The most notable effect is that the coolest area of the cornea moves at a point of 2 mm inferior to its geometric centre. The maximum velocity of the fluid in the anterior chamber was found to be 3.36 x 10 -4 m s -1 . The effect of the flow on displacing the cool area of the corneal surface temperature is counterbalanced by assuming anisotropic thermal conductivity. The model was implemented in the case of an artificial intraocular lens to show the resulting temperature variations.

  16. Intermediate view synthesis for eye-gazing

    Science.gov (United States)

    Baek, Eu-Ttuem; Ho, Yo-Sung

    2015-01-01

    Nonverbal communication, also known as body language, is an important form of communication. Nonverbal behaviors such as posture, eye contact, and gestures send strong messages. In regard to nonverbal communication, eye contact is one of the most important forms that an individual can use. However, lack of eye contact occurs when we use video conferencing system. The disparity between locations of the eyes and a camera gets in the way of eye contact. The lock of eye gazing can give unapproachable and unpleasant feeling. In this paper, we proposed an eye gazing correction for video conferencing. We use two cameras installed at the top and the bottom of the television. The captured two images are rendered with 2D warping at virtual position. We implement view morphing to the detected face, and synthesize the face and the warped image. Experimental results verify that the proposed system is effective in generating natural gaze-corrected images.

  17. Through Human Eyes: A New Approach to the Problem of Workforces in Remote Areas.

    Science.gov (United States)

    Simmonds, W. H. C.

    The often unstable workforce in remote areas can possibly be strengthened by stabilizing adjacent human settlements with community design which works from the inside out to emphasize the human, social, cultural, and environmental aspects of the settlements. Because stresses resulting from isolation, loss of social relationships, lack of…

  18. Human Rights and the Ethno-Nationalist Problematic through the Eyes of Greek-Cypriot Teachers

    Science.gov (United States)

    Zembylas, Michalinos; Charalambous, Panayiota; Charalambous, Constadina; Lesta, Stalo

    2016-01-01

    The present article aims to examine the interplay between the transnational discourses of human rights and the particularities of local constructions and conceptualisations of human rights within the context of an ethnically divided society, Cyprus. Specifically, this interplay is examined through a qualitative study of Greek-Cypriot primary…

  19. Evaluating skin-protective materials against contact irritants and allergens. An in vivo screening human model.

    Science.gov (United States)

    Zhai, H; Willard, P; Maibach, H I

    1998-03-01

    2 acute irritants and 1 allergen were selected: sodium lauryl sulfate (SLS) representative of irritant household and occupational contact dermatitis, the combination of ammonium hydroxide (NH4OH) and urea to simulate diaper dermatitis, and Rhus to evaluate the effect of model protective materials. The putative protective materials and vehicle were applied to both ventral forearms of 10 subjects in each group, according to a randomized code. Test materials were spread over a marked 2.0 cm2 area, massaged in, allowed to dry for 30 min, and reapplied with another 30 min drying period. The model irritants and allergen were then applied (0.025 ml) to an Al-test occlusive patch, which in turn was placed for 24 h over each of the 8 designated sites. Inflammation was scored according to a clinical scale 72 h post-application. Paraffin wax plus Acetulan in cetyl alcohol, and beeswax plus Acetulan in cetyl alcohol, markedly (p < 0.001) suppressed SLS irritation. Paraffin wax plus beeswax in cetyl alcohol, and Acetulan in cetyl alcohol reduced NH4OH and urea irritation (p < 0.05), paraffin wax in cetyl alcohol significantly (p < 0.01) decreasing Rhus allergic contact dermatitis. This model, provides an easy approach to screening protectants. Its clinical significance requires comparison with an open rather than an occluded challenge.

  20. Analysis of the Viscoelastic Properties of the Human Cornea Using Scheimpflug Imaging in Inflation Experiment of Eye Globes

    Science.gov (United States)

    Lombardo, Giuseppe; Serrao, Sebastiano; Rosati, Marianna; Lombardo, Marco

    2014-01-01

    Purpose To demonstrate a Scheimpflug-based imaging procedure for investigating the depth- and time-dependent strain response of the human cornea to inflation testing of whole eye globes. Methods Six specimens, three of which with intact corneal epithelium, were mounted in a customized apparatus within a humidity and temperature-monitored wet chamber. Each specimen was subjected to two mechanical tests in order to measure corneal strain resulting from application of cyclic (cyclic regimen) and constant (creep regimen) stress by changing the intra-ocular pressure (IOP) within physiological ranges (18–42 mmHg). Corneal shape changes were analyzed as a function of IOP and both corneal stress-strain curves and creep curves were generated. Results The procedure was highly accurate and repeatable. Upon cyclic stress application, a biomechanical corneal elasticity gradient was found in the front-back direction. The average Young's modulus of the anterior cornea ranged between 2.28±0.87 MPa and 3.30±0.90 MPa in specimens with and without intact epithelium (P = 0.05) respectively. The Young's modulus of the posterior cornea was on average 0.21±0.09 MPa and 0.17±0.06 MPa (P>0.05) respectively. The time-dependent strain response of the cornea to creep testing was quantified by fitting data to a modified Zener model for extracting both the relaxation time and compliance function. Conclusion Cyclic and creep mechanical tests are valuable for investigating the strain response of the intact human cornea within physiological IOP ranges, providing meaningful results that can be translated to clinic. The presence of epithelium influences the results of anterior corneal shape changes when monitoring deformation via Scheimpflug imaging in inflation experiments of whole eye globes. PMID:25397674

  1. SU-G-IeP4-09: Method of Human Eye Aberration Measurement Using Plenoptic Camera Over Large Field of View

    Energy Technology Data Exchange (ETDEWEB)

    Lv, Yang; Wang, Ruixing; Ma, Haotong; Zhang, Xuanzhe; Ning, Yu; Xu, Xiaojun [College of Optoelectronic Science and Engineering, National University of Defense Technology, Changsha (China)

    2016-06-15

    Purpose: The measurement based on Shack-Hartmann wave-front sensor(WFS), obtaining both the high and low order wave-front aberrations simultaneously and accurately, has been applied in the detection of human eyes aberration in recent years. However, Its application is limited by the small field of view (FOV), slight eye movement leads the optical bacon image exceeds the lenslet array which result in uncertain detection error. To overcome difficulties of precise eye location, the capacity of detecting eye wave-front aberration over FOV much larger than simply a single conjugate Hartmann WFS accurately and simultaneously is demanded. Methods: Plenoptic camera’s lenslet array subdivides the aperture light-field in spatial frequency domain, capture the 4-D light-field information. Data recorded by plenoptic cameras can be used to extract the wave-front phases associated to the eyes aberration. The corresponding theoretical model and simulation system is built up in this article to discuss wave-front measurement performance when utilizing plenoptic camera as wave-front sensor. Results: The simulation results indicate that the plenoptic wave-front method can obtain both the high and low order eyes wave-front aberration with the same accuracy as conventional system in single visual angle detectionand over FOV much larger than simply a single conjugate Hartmann systems. Meanwhile, simulation results show that detection of eye aberrations wave-front in different visual angle can be achieved effectively and simultaneously by plenoptic method, by both point and extended optical beacon from the eye. Conclusion: Plenoptic wave-front method possesses the feasibility in eye aberrations wave-front detection. With larger FOV, the method can effectively reduce the detection error brought by imprecise eye location and simplify the eye aberrations wave-front detection system comparing with which based on Shack-Hartmann WFS. Unique advantage of the plenoptic method lies in obtaining

  2. SU-G-IeP4-09: Method of Human Eye Aberration Measurement Using Plenoptic Camera Over Large Field of View

    International Nuclear Information System (INIS)

    Lv, Yang; Wang, Ruixing; Ma, Haotong; Zhang, Xuanzhe; Ning, Yu; Xu, Xiaojun

    2016-01-01

    Purpose: The measurement based on Shack-Hartmann wave-front sensor(WFS), obtaining both the high and low order wave-front aberrations simultaneously and accurately, has been applied in the detection of human eyes aberration in recent years. However, Its application is limited by the small field of view (FOV), slight eye movement leads the optical bacon image exceeds the lenslet array which result in uncertain detection error. To overcome difficulties of precise eye location, the capacity of detecting eye wave-front aberration over FOV much larger than simply a single conjugate Hartmann WFS accurately and simultaneously is demanded. Methods: Plenoptic camera’s lenslet array subdivides the aperture light-field in spatial frequency domain, capture the 4-D light-field information. Data recorded by plenoptic cameras can be used to extract the wave-front phases associated to the eyes aberration. The corresponding theoretical model and simulation system is built up in this article to discuss wave-front measurement performance when utilizing plenoptic camera as wave-front sensor. Results: The simulation results indicate that the plenoptic wave-front method can obtain both the high and low order eyes wave-front aberration with the same accuracy as conventional system in single visual angle detectionand over FOV much larger than simply a single conjugate Hartmann systems. Meanwhile, simulation results show that detection of eye aberrations wave-front in different visual angle can be achieved effectively and simultaneously by plenoptic method, by both point and extended optical beacon from the eye. Conclusion: Plenoptic wave-front method possesses the feasibility in eye aberrations wave-front detection. With larger FOV, the method can effectively reduce the detection error brought by imprecise eye location and simplify the eye aberrations wave-front detection system comparing with which based on Shack-Hartmann WFS. Unique advantage of the plenoptic method lies in obtaining

  3. Eye Protection

    OpenAIRE

    Pashby, Tom

    1986-01-01

    Eye injuries frequently occur in the home, at work and at play. Many result in legally blind eyes, and most are preventable. Awareness of potential hazards is essential to preventing eye injuries, particularly in children. In addition, protective devices must be used appropriately. We have developed eye protectors that have proved effective in reducing both the overall incidence and the severity of sports eye injuries.

  4. Comparison of rhythmic masticatory muscle activity during non-rapid eye movement sleep in guinea pigs and humans.

    Science.gov (United States)

    Kato, Takafumi; Toyota, Risa; Haraki, Shingo; Yano, Hiroyuki; Higashiyama, Makoto; Ueno, Yoshio; Yano, Hiroshi; Sato, Fumihiko; Yatani, Hirofumi; Yoshida, Atsushi

    2017-09-27

    Rhythmic masticatory muscle activity can be a normal variant of oromotor activity, which can be exaggerated in patients with sleep bruxism. However, few studies have tested the possibility in naturally sleeping animals to study the neurophysiological mechanisms of rhythmic masticatory muscle activity. This study aimed to investigate the similarity of cortical, cardiac and electromyographic manifestations of rhythmic masticatory muscle activity occurring during non-rapid eye movement sleep between guinea pigs and human subjects. Polysomnographic recordings were made in 30 freely moving guinea pigs and in eight healthy human subjects. Burst cycle length, duration and activity of rhythmic masticatory muscle activity were compared with those for chewing. The time between R-waves in the electrocardiogram (RR interval) and electroencephalogram power spectrum were calculated to assess time-course changes in cardiac and cortical activities in relation to rhythmic masticatory muscle activity. In animals, in comparison with chewing, rhythmic masticatory muscle activity had a lower burst activity, longer burst duration and longer cycle length (P motor activation in comparison to human subjects. © 2017 European Sleep Research Society.

  5. A review of technology-assisted self-help and minimal contact therapies for drug and alcohol abuse and smoking addiction: is human contact necessary for therapeutic efficacy?

    Science.gov (United States)

    Newman, Michelle G; Szkodny, Lauren E; Llera, Sandra J; Przeworski, Amy

    2011-02-01

    Technology-based self-help and minimal contact therapies have been proposed as effective and low-cost interventions for addictive disorders, such as nicotine, alcohol, and drug abuse and addiction. The present article reviews the literature published before 2010 on computerized treatments for drug and alcohol abuse and dependence and smoking addiction. Treatment studies are examined by disorder as well as amount of therapist contact, ranging from self-administered therapy and predominantly self-help interventions to minimal contact therapy where the therapist is actively involved in treatment but to a lesser degree than traditional therapy and predominantly therapist-administered treatments involving regular contact with a therapist for a typical number of sessions. In the treatment of substance use and abuse it is concluded that self-administered and predominantly self-help computer-based cognitive and behavioral interventions are efficacious, but some therapist contact is important for greater and more sustained reductions in addictive behavior. Copyright © 2010 Elsevier Ltd. All rights reserved.

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye Health / News Halloween Hazard: The Hidden Dangers ... Decorative Contact Lenses Without a Prescription Leer en Español: Peligros asociados con los lentes de contacto de ...

  7. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Español Eye Health / News Halloween Hazard: The Hidden Dangers of Buying Decorative Contact Lenses Without a Prescription ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ...

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... can be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... ask for a prescription. There is no such thing as a "one size fits all" contact lens. Lenses that are not properly fitted may scratch the eye or cause blood vessels to grow into ...

  9. About the Eye

    Medline Plus

    Full Text Available ... Accomplishments Budget and Congress About the NEI Director History of the NEI NEI 50th Anniversary NEI Women Scientists Advisory Committee (WSAC) Board of Scientific Counselors National Advisory Eye Council (NAEC) Donating to the NEI Contact Us Visiting the NIH Campus Mission Statement As part ...

  10. About the Eye

    Medline Plus

    Full Text Available ... with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the ... Contact Us A-Z Site Map NEI on Social Media Information in Spanish (Información en español) Website, ...

  11. About the Eye

    Medline Plus

    Full Text Available ... to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health problems and requirements of ... Pressroom Contacts Dustin Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media Relations ...

  12. About the Eye

    Medline Plus

    Full Text Available ... programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health ... Pressroom Contacts Dustin Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media Relations ...

  13. Local air gap thickness and contact area models for realistic simulation of human thermo-physiological response

    Science.gov (United States)

    Psikuta, Agnes; Mert, Emel; Annaheim, Simon; Rossi, René M.

    2018-02-01

    To evaluate the quality of new energy-saving and performance-supporting building and urban settings, the thermal sensation and comfort models are often used. The accuracy of these models is related to accurate prediction of the human thermo-physiological response that, in turn, is highly sensitive to the local effect of clothing. This study aimed at the development of an empirical regression model of the air gap thickness and the contact area in clothing to accurately simulate human thermal and perceptual response. The statistical model predicted reliably both parameters for 14 body regions based on the clothing ease allowances. The effect of the standard error in air gap prediction on the thermo-physiological response was lower than the differences between healthy humans. It was demonstrated that currently used assumptions and methods for determination of the air gap thickness can produce a substantial error for all global, mean, and local physiological parameters, and hence, lead to false estimation of the resultant physiological state of the human body, thermal sensation, and comfort. Thus, this model may help researchers to strive for improvement of human thermal comfort, health, productivity, safety, and overall sense of well-being with simultaneous reduction of energy consumption and costs in built environment.

  14. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Mar 29, 2017 New Technology Helps the Legally Blind Be More Independent Oct 31, 2016 More Eye ... but intriguing study, scientists in England have given blind patients some functional vision, using human embryonic stem ...

  15. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Independent Oct 31, 2016 More Eye Health News Stem Cells May Return Some Vision Lost to Wet AMD ... blind patients some functional vision, using human embryonic stem cells. Two blind patients regained enough sight to read ...

  16. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... for people with high myopia? Mar 29, 2017 New Technology Helps the Legally Blind Be More Independent Oct ... re edging closer, thanks to a wave of new technologies aiming to fix failing eye parts with human- ...

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Mar 29, 2017 More Eye Health News Stem Cells May Return Some Vision Lost to Wet AMD ... patients some functional vision, using human embryonic stem cells. Two blind patients regained enough sight to read ...

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Oct 31, 2016 More Eye Health News Stem Cells May Return Some Vision Lost to Wet AMD ... patients some functional vision, using human embryonic stem cells. Two blind patients regained enough sight to read ...

  19. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... people with high myopia? Mar 29, 2017 New Technology Helps the Legally Blind Be More Independent Oct ... edging closer, thanks to a wave of new technologies aiming to fix failing eye parts with human- ...

  20. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... edging closer, thanks to a wave of new technologies aiming to fix failing eye parts with human-made versions. ... difference is between ophthalmologists and optometrists? A medical degree and many more years of training, for ...

  1. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... myopia? Mar 29, 2017 More Eye Health News Stem Cells May Return Some Vision Lost to Wet AMD ... blind patients some functional vision, using human embryonic stem cells. Two blind patients regained enough sight to read ...

  2. About the Eye

    Medline Plus

    Full Text Available ... The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips ... addressed to the NEI Website Manager . Department of Health and Human Services | The National Institutes of Health | ...

  3. Prediction of temperature and damage in an irradiated human eye-Utilization of a detailed computer model which includes a vectorial blood stream in the choroid.

    Science.gov (United States)

    Heussner, Nico; Holl, Lukas; Nowak, Timo; Beuth, Thorsten; Spitzer, Martin S; Stork, Wilhelm

    2014-08-01

    The work presented here describes the development and use of a three-dimensional thermo-dynamic model of the human eye for the prediction of temperatures and damage thresholds under irradiation. This model takes into account the blood flow by the implementation of a vectorial blood stream in the choroid and also uses the actual physiological extensions and tissue parameters of the eye. Furthermore it considers evaporation, radiation and convection at the cornea as well as the eye lid. The predicted temperatures were successfully validated against existing eye models in terms of corneal and global thermal behaviour. The model׳s predictions were additionally checked for consistency with in-vivo temperature measurements of the cornea, the irradiated retina and its damage thresholds. These thresholds were calculated from the retinal temperatures using the Arrhenius integral. Hence the model can be used to predict the temperature increase and irradiation hazard within the human eye as long as the absorption values and the Arrhenius coefficients are known and the damage mechanism is in the thermal regime. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Dietary Supplementation with a Combination of Lactoferrin, Fish Oil, and Enterococcus faecium WB2000 for Treating Dry Eye: A Rat Model and Human Clinical Study.

    Science.gov (United States)

    Kawashima, Motoko; Nakamura, Shigeru; Izuta, Yusuke; Inoue, Sachiko; Tsubota, Kazuo

    2016-04-01

    To examine the effect of a combined dietary supplement containing fish oil, lactoferrin, zinc, vitamin C, lutein, vitamin E, γ-aminobutanoic acid, and Enterococcus faecium WB2000 on dry eye. A preliminary study in a rat model and a prospective, randomized, double-blind, placebo-controlled study in humans were conducted. Forty Japanese volunteers aged 22 to 59 years were randomized into combined dietary supplement (2 capsules/day; 20 participants) and placebo (vehicle; 19 participants) groups and treated once daily for 8 weeks. Rats received the combined dietary supplement components (10 or 50 mg/kg orally) or vehicle (2% DMSO), and dry eye was mechanically induced for 2 days. Tear production was measured in rats after dry eye was induced. Humans were assessed at baseline and weeks 4 and 8 post-supplementation based on keratoconjunctival epithelial damage; fluorescein tear film breakup time; tear production; biochemical data; information regarding subjective dry eye symptoms by answering a questionnaire; and information regarding adverse events via medical interviews. Supplementation dose-dependently mitigated the decrease in tear production in rats. Among subjects with confirmed dry eye, clinical symptoms improved at weeks 4 and 8 more significantly in the supplementation group than in the placebo group (Peye symptoms. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Spherical aberration and other higher-order aberrations in the human eye : from summary wave-front analysis data to optical variables relevant to visual perception

    NARCIS (Netherlands)

    Jansonius, Nomdo M.

    Wave-front analysis data from the human eye are commonly presented using the aberration coefficient c(4)(0) (primary spherical aberration) together with an overall measure of all higher-order aberrations. If groups of subjects are compared, however, the relevance of an observed difference cannot

  6. Computing the stresses and deformations of the human eye components due to a high explosive detonation using fluid-structure interaction model.

    Science.gov (United States)

    Karimi, Alireza; Razaghi, Reza; Navidbakhsh, Mahdi; Sera, Toshihiro; Kudo, Susumu

    2016-05-01

    In spite the fact that a very small human body surface area is comprised by the eye, its wounds due to detonation have recently been dramatically amplified. Although many efforts have been devoted to measure injury of the globe, there is still a lack of knowledge on the injury mechanism due to Primary Blast Wave (PBW). The goal of this study was to determine the stresses and deformations of the human eye components, including the cornea, aqueous, iris, ciliary body, lens, vitreous, retina, sclera, optic nerve, and muscles, attributed to PBW induced by trinitrotoluene (TNT) explosion via a Lagrangian-Eulerian computational coupling model. Magnetic Resonance Imaging (MRI) was employed to establish a Finite Element (FE) model of the human eye according to a normal human eye. The solid components of the eye were modelled as Lagrangian mesh, while an explosive TNT, air domain, and aqueous were modelled using Arbitrary Lagrangian-Eulerian (ALE) mesh. Nonlinear dynamic FE simulations were accomplished using the explicit FE code, namely LS-DYNA. In order to simulate the blast wave generation, propagation, and interaction with the eye, the ALE formulation with Jones-Wilkins-Lee (JWL) equation defining the explosive material were employed. The results revealed a peak stress of 135.70kPa brought about by detonation upsurge on the cornea at the distance of 25cm. The highest von Mises stresses were observed on the sclera (267.3kPa), whereas the lowest one was seen on the vitreous body (0.002kPa). The results also showed a relatively high resultant displacement for the macula as well as a high variation for the radius of curvature for the cornea and lens, which can result in both macular holes, optic nerve damage and, consequently, vision loss. These results may have implications not only for understanding the value of stresses and strains in the human eye components but also giving an outlook about the process of PBW triggers damage to the eye. Copyright © 2016 Elsevier Ltd

  7. Immunohistochemical markers for corneal stem cells in the early developing human eye

    DEFF Research Database (Denmark)

    Lyngholm, Mikkel; Høyer, Poul E; Vorum, Henrik

    2008-01-01

    niche (week 14) in human embryos and fetuses. The expression of SOD2 and CK15 was investigated together with other recently identified limbal proteins. Previously suggested LSC and differentiation markers (PAX6, aquaporin-1 and nestin) were also investigated. Both SOD2 and CK15 were present...... markers and potential markers for LSCs and early transient amplifying cells in human adults. In this study, we describe the development of the ectodermally derived LSCs and the mesodermally derived niche cells from the time at which the cornea is defined (week 6) until the formation of the early limbal...

  8. The digital aqueous humor outflow meter: an alternative tool for screening of the human eye outflow facility

    Directory of Open Access Journals (Sweden)

    Vassilios P Kozobolis

    2010-08-01

    Full Text Available Vassilios P Kozobolis, Eleftherios I Paschalis, Nikitas C Foudoulakis, Stavrenia C Koukoula, Georgios LabirisDepartment of Ophthalmology and Eye Institute of Thrace, Democritus University of Thrace, Alexandroupolis, GreecePurpose: To develop, characterize, and validate a prototype digital aqueous humor outflow tonographer (DAHOM.Material and methods: The DAHOM was developed, characterized, and validated in three phases. Phase 1 involved construction of the sensor. This was broadly based on the fundamental design of a typical Schiotz tonographer with a series of improvements, including corneal indentation, which was converted to an electrical signal via a linear variable differential transducer, an analog signal which was converted to digital via ADC circuitry, and digital data acquisition and processing which was made possible by a serial port interface. Phase 2 comprised development of software for automated assessment of the outflow facility. Automated outflow facility assessment incorporated a series of fundamental improvements in comparison with traditional techniques, including software-based filtering of ripple noise and extreme variations, rigidity impact analysis, and evaluation of the impact of patient age, central corneal thickness, and ocular axial length. Phase 3 comprised characterization and validation of DAHOM, for which we developed an experimental setup using porcine cadaver eyes. DAHOM’s repeatability was evaluated by means of Cronbach’s alpha and intraclass correlation coefficient. The level of agreement with a standard Schiotz tonographer was evaluated by means of paired t-tests and Bland-Altman analysis in human eyes.Results: The experimental setup provided the necessary data for the characterization of DAHOM. A fourth order polynomial equation provided excellent fit (R square >0.999. DAHOM demonstrated high repeatability (Cronbach’s alpha ≥0.997; intraclass correlation coefficient ≥0.987 and an adequate level of

  9. Mapping human resources for eye health in 21 countries of sub-Saharan Africa: current progress towards VISION 2020

    Science.gov (United States)

    2014-01-01

    Background Development of human resources for eye health (HReH) is a major focus of the Global Action Plan 2014 to 2019 to reduce the prevalence of avoidable visual impairment by 25% by the year 2019. The eye health workforce is thought to be much smaller in sub-Saharan Africa than in other regions of the world but data to support this for policy-making is scarce. We collected HReH and cataract surgeries data from 21 countries in sub-Sahara to estimate progress towards key suggested population-based VISION 2020 HReH indicators and cataract surgery rates (CSR) in 2011. Methods Routinely collected data on practitioner and surgery numbers in 2011 was requested from national eye care coordinators via electronic questionnaires. Telephone and e-mail discussions were used to determine data collection strategies that fit the national context and to verify reported data quality. Information was collected on six practitioner cadres: ophthalmologists, cataract surgeons, ophthalmic clinical officers, ophthalmic nurses, optometrists and ‘mid-level refractionists’ and combined with publicly available population data to calculate practitioner to population ratios and CSRs. Associations with development characteristics were conducted using Wilcoxon rank sum tests and Spearman rank correlations. Results HReH data was not easily available. A minority of countries had achieved the suggested VISION 2020 targets in 2011; five countries for ophthalmologists/cataract surgeons, four for ophthalmic nurses/clinical officers and two for CSR. All countries were below target for optometrists, even when other cadres who perform refractions as a primary duty were considered. The regional (sample) ratio for surgeons (ophthalmologists and cataract surgeons) was 2.9 per million population, 5.5 for ophthalmic clinical officers and nurses, 3.7 for optometrists and other refractionists, and 515 for CSR. A positive correlation between GDP and CSR as well as many practitioner ratios was observed

  10. Mapping human resources for eye health in 21 countries of sub-Saharan Africa: current progress towards VISION 2020.

    Science.gov (United States)

    Palmer, Jennifer J; Chinanayi, Farai; Gilbert, Alice; Pillay, Devan; Fox, Samantha; Jaggernath, Jyoti; Naidoo, Kovin; Graham, Ronnie; Patel, Daksha; Blanchet, Karl

    2014-08-15

    Development of human resources for eye health (HReH) is a major focus of the Global Action Plan 2014 to 2019 to reduce the prevalence of avoidable visual impairment by 25% by the year 2019. The eye health workforce is thought to be much smaller in sub-Saharan Africa than in other regions of the world but data to support this for policy-making is scarce. We collected HReH and cataract surgeries data from 21 countries in sub-Sahara to estimate progress towards key suggested population-based VISION 2020 HReH indicators and cataract surgery rates (CSR) in 2011. Routinely collected data on practitioner and surgery numbers in 2011 was requested from national eye care coordinators via electronic questionnaires. Telephone and e-mail discussions were used to determine data collection strategies that fit the national context and to verify reported data quality. Information was collected on six practitioner cadres: ophthalmologists, cataract surgeons, ophthalmic clinical officers, ophthalmic nurses, optometrists and 'mid-level refractionists' and combined with publicly available population data to calculate practitioner to population ratios and CSRs. Associations with development characteristics were conducted using Wilcoxon rank sum tests and Spearman rank correlations. HReH data was not easily available. A minority of countries had achieved the suggested VISION 2020 targets in 2011; five countries for ophthalmologists/cataract surgeons, four for ophthalmic nurses/clinical officers and two for CSR. All countries were below target for optometrists, even when other cadres who perform refractions as a primary duty were considered. The regional (sample) ratio for surgeons (ophthalmologists and cataract surgeons) was 2.9 per million population, 5.5 for ophthalmic clinical officers and nurses, 3.7 for optometrists and other refractionists, and 515 for CSR. A positive correlation between GDP and CSR as well as many practitioner ratios was observed (CSR P = 0

  11. Tribology of human skin and mechanical skin equivalents in contact with textiles

    NARCIS (Netherlands)

    Derler, S.; Schrade, G.U.; Gerhardt, L.C.

    2007-01-01

    The friction of untreated human skin (finger) against a reference textile was investigated with 12 subjects using a force plate. In touch experiments, in which the subjects assessed the surface roughness of the textile at normal loads of 1.5 ± 0.7 N, the average friction coefficients ranged from

  12. LIMNOLOGICAL OPTOMETRY: EXAMINING EARTH'S EYE

    Science.gov (United States)

    In Thoreau's Walden, a lake is described as the landscape's most expressive feature and the earth's eye. Collectively, scientists are charged by society to assess, monitor, and remedy maladies of earth's eye in the same way optometrists maintain the health of the human eye. This ...

  13. Accommodation in human eye models: a comparison between the optical designs of Navarro, Arizona and Liou-Brennan.

    Science.gov (United States)

    Zoulinakis, Georgios; Esteve-Taboada, Jose Juan; Ferrer-Blasco, Teresa; Madrid-Costa, David; Montés-Micó, Robert

    2017-01-01

    To simulate and compare accommodation in accommodative and non-accommodative human eye models. Ray tracing and optical design program was used. Three eye models were designed and studied: the Navarro, the Arizona and the Liou-Brennan. In order to make the Navarro and Liou-Brennan models to accommodate, specific geometric parameters of the models were altered with values that were chosen from the literature. For the Arizona model, its' mathematical functions for accommodation were used for the same accommodative demands. The simulation included four distances of accommodation for each model: at infinity, 3, 1 and 0.5 m.The results were diffraction images of a "letter F" for graphical comparison, spot diagrams on the retinal field and Modulation Transfer Function (MTF) graphs. Zernike coefficients for the aberrations, Airy disk diameter, root mean square (RMS) error diameter and total axial length of the model were provided from the program. These were compared between them in all distances. The Navarro model had the smallest axial length change as a simple model. The Arizona did not change its axial length because it is designed to be accommodative. The Liou-Brennan model had different results concerning the aberrations because of the decentration of the pupil. The MTF graphs showed small differences between the models because of the differences in their designs. All the three models are able to simulate accommodation with the expected results. There is no model that can be assumed as the best choice. Accommodation can be simulated in non-accommodativemodels and in customized ones.

  14. Radiocarbon dating of the human eye lens crystallines reveal proteins without carbon turnover throughout life

    DEFF Research Database (Denmark)

    Lynnerup, Niels; Kjeldsen, Henrik; Heegaard, Steffen

    2008-01-01

    , there is no subsequent remodelling of these fibers, nor removal of degraded lens fibers. Human tissue ultimately derives its (14)C content from the atmospheric carbon dioxide. The (14)C content of the lens proteins thus reflects the atmospheric content of (14)C when the lens crystallines were formed. Precise radiocarbon...

  15. Collagen VII deficient mice show morphologic and histologic corneal changes that phenotypically mimic human dystrophic epidermolysis bullosa of the eye.

    Science.gov (United States)

    Chen, Vicki M; Shelke, Rajani; Nyström, Alexander; Laver, Nora; Sampson, James F; Zhiyi, Cao; Bhat, Najma; Panjwani, Noorjahan

    2018-06-16

    Absence of collagen VII causes blistering of the skin, eyes and many other tissues. This disease is termed dystrophic epidermolysis bullosa (DEB). Corneal fibrosis occurs in up to 41% and vision loss in up to 64% of patients. Standard treatments are supportive and there is no cure. The immune-histologic and morphologic changes in the corneas of the mouse model for this disease have not been described in the literature. Our purpose is to characterize the eyes of these mice to determine if this is an appropriate model for study of human therapeutics. Western blot analysis (WB) and immunohistochemistry (IHC) were performed to assess the relative collagen VII protein levels and its location within the cornea. Additional IHC for inflammatory and fibrotic biomarkers alpha-smooth muscle actin (α-SMA), transforming growth factor-beta (TGF-β), connective tissue growth factor (CTGF), proteinase 3, tenascin C and collagen III were performed. Clinical photographs documenting opacification of the corneas of animals of differing ages were assessed and scored independently by 2 examiners. Histology was then used to investigate morphologic changes. IHC and WB confirmed that these mice are deficient in collagen VII production at the level of the basement membrane when compared with wild-types. IHC showed anomalous deposition of collagen III throughout the stroma. Of the 5 biomarkers tested, TGF-β showed the strongest and most consistently staining. Photographs documented corneal opacities only in mice older than 10 weeks, opacities were not seen in younger animals. Histology showed multiple abnormalities, including epithelial hyperplasia, ulceration, fibrosis, edema, dysplasia, neovascularization and bullae formation. The collagen VII hypomorphic mouse shows reduced collagen VII production at the level of the corneal basement membrane. Corneal changes are similar to pathology seen in humans with this disease. The presence of anomalous stromal collagen III and TGF-β appear to be

  16. Effects of Long-Term Exposure to 60 GHz Millimeter-Wavelength Radiation on the Genotoxicity and Heat Shock Protein (Hsp Expression of Cells Derived from Human Eye

    Directory of Open Access Journals (Sweden)

    Shin Koyama

    2016-08-01

    Full Text Available Human corneal epithelial (HCE-T and human lens epithelial (SRA01/04 cells derived from the human eye were exposed to 60 gigahertz (GHz millimeter-wavelength radiation for 24 h. There was no statistically significant increase in the micronucleus (MN frequency in cells exposed to 60 GHz millimeter-wavelength radiation at 1 mW/cm2 compared with sham-exposed controls and incubator controls. The MN frequency of cells treated with bleomycin for 1 h provided positive controls. The comet assay, used to detect DNA strand breaks, and heat shock protein (Hsp expression also showed no statistically significant effects of exposure. These results indicate that exposure to millimeter-wavelength radiation has no effect on genotoxicity in human eye cells.

  17. Imparting albumin-binding affinity to a human protein by mimicking the contact surface of a bacterial binding protein.

    Science.gov (United States)

    Oshiro, Satoshi; Honda, Shinya

    2014-04-18

    Attachment of a bacterial albumin-binding protein module is an attractive strategy for extending the plasma residence time of protein therapeutics. However, a protein fused with such a bacterial module could induce unfavorable immune reactions. To address this, we designed an alternative binding protein by imparting albumin-binding affinity to a human protein using molecular surface grafting. The result was a series of human-derived 6 helix-bundle proteins, one of which specifically binds to human serum albumin (HSA) with adequate affinity (KD = 100 nM). The proteins were designed by transferring key binding residues of a bacterial albumin-binding module, Finegoldia magna protein G-related albumin-binding domain (GA) module, onto the human protein scaffold. Despite 13-15 mutations, the designed proteins maintain the original secondary structure by virtue of careful grafting based on structural informatics. Competitive binding assays and thermodynamic analyses of the best binders show that the binding mode resembles that of the GA module, suggesting that the contacting surface of the GA module is mimicked well on the designed protein. These results indicate that the designed protein may act as an alternative low-risk binding module to HSA. Furthermore, molecular surface grafting in combination with structural informatics is an effective approach for avoiding deleterious mutations on a target protein and for imparting the binding function of one protein onto another.

  18. Manipulation of pre-target activity on the right frontal eye field enhances conscious visual perception in humans.

    Directory of Open Access Journals (Sweden)

    Lorena Chanes

    Full Text Available The right Frontal Eye Field (FEF is a region of the human brain, which has been consistently involved in visuo-spatial attention and access to consciousness. Nonetheless, the extent of this cortical site's ability to influence specific aspects of visual performance remains debated. We hereby manipulated pre-target activity on the right FEF and explored its influence on the detection and categorization of low-contrast near-threshold visual stimuli. Our data show that pre-target frontal neurostimulation has the potential when used alone to induce enhancements of conscious visual detection. More interestingly, when FEF stimulation was combined with visuo-spatial cues, improvements remained present only for trials in which the cue correctly predicted the location of the subsequent target. Our data provide evidence for the causal role of the right FEF pre-target activity in the modulation of human conscious vision and reveal the dependence of such neurostimulatory effects on the state of activity set up by cue validity in the dorsal attentional orienting network.

  19. Space representation for eye movements is more contralateral in monkeys than in humans

    OpenAIRE

    Kagan, Igor; Iyer, Asha; Lindner, Axel; Andersen, Richard A.

    2010-01-01

    Contralateral hemispheric representation of sensory inputs (the right visual hemifield in the left hemisphere and vice versa) is a fundamental feature of primate sensorimotor organization, in particular the visuomotor system. However, many higher-order cognitive functions in humans show an asymmetric hemispheric lateralization—e.g., right brain specialization for spatial processing—necessitating a convergence of information from both hemifields. Electrophysiological studies in monkeys and fun...

  20. [Autoshaping of a button-push response and eye movement in human subjects].

    Science.gov (United States)

    Kimura, H; Fukui, I; Inaki, K

    1990-12-01

    Two experiments were conducted with human subjects to investigate the similarities and differences between animal and human behaviors under autoshaping procedures. In these experiments, light served as CS, and display on TV served as US. Whether the pushing button response or gazing response to CS could be obtained in human subjects under Pavlovian conditioning procedure was examined. In Experiment 1, uninstructed naive subjects were placed in a room containing a push-button and a TV display. Within the experimental sessions, the push-button was lit for 8 s as CS, and then paired with the display of a soft pornographic program on TV for 10 s. The result indicated that the modeling of pushing button promoted the increase of response probability among the subjects. The trials conducted after the rest period indicated an increase of response probability. In Experiment 2, a 4 cm square translucent panel was lit for 20 s as CS, and then paired with the display of a computer graphic picture on TV for 8 s as US. Some subjects started gazing at the CS for several seconds. These results indicated that some subjects could acquire the gazing response under the autoshaping procedure.